[Practical experience about the compatibility of PDF converter in ECG information system].
Yang, Gang; Lu, Weishi; Zhou, Jiacheng
2009-11-01
To find a way to view ECG from different manufacturers in electrocardiogram information system. Different format ECG data were transmitted to ECG center by different ways. Corresponding analysis software was used to make the diagnosis reports in the center. Then we use PDF convert to change all ECG reports into PDF format. The electrocardiogram information system manage these PDF format ECG data for clinic user. The ECG reports form several major ECG manufacturers were transformed to PDF format successfully. In the electrocardiogram information system it is freely to view the ECG figure. PDF format ECG report is a practicable way to solve the compatibility problem in electrocardiogram information system.
Hernández-Padilla, José M; Granero-Molina, José; Márquez-Hernández, Verónica V; Suthers, Fiona; López-Entrambasaguas, Olga M; Fernández-Sola, Cayetano
2017-06-01
Rapid and accurate interpretation of cardiac arrhythmias by nurses has been linked with safe practice and positive patient outcomes. Although training in electrocardiogram rhythm recognition is part of most undergraduate nursing programmes, research continues to suggest that nurses and nursing students lack competence in recognising cardiac rhythms. In order to promote patient safety, nursing educators must develop valid and reliable assessment tools that allow the rigorous assessment of this competence before nursing students are allowed to practise without supervision. The aim of this study was to develop and psychometrically evaluate a toolkit to holistically assess competence in electrocardiogram rhythm recognition. Following a convenience sampling technique, 293 nursing students from a nursing faculty in a Spanish university were recruited for the study. The following three instruments were developed and psychometrically tested: an electrocardiogram knowledge assessment tool (ECG-KAT), an electrocardiogram skills assessment tool (ECG-SAT) and an electrocardiogram self-efficacy assessment tool (ECG-SES). Reliability and validity (content, criterion and construct) of these tools were meticulously examined. A high Cronbach's alpha coefficient demonstrated the excellent reliability of the instruments (ECG-KAT=0.89; ECG-SAT=0.93; ECG-SES=0.98). An excellent context validity index (scales' average content validity index>0.94) and very good criterion validity were evidenced for all the tools. Regarding construct validity, principal component analysis revealed that all items comprising the instruments contributed to measure knowledge, skills or self-efficacy in electrocardiogram rhythm recognition. Moreover, known-groups analysis showed the tools' ability to detect expected differences in competence between groups with different training experiences. The three-instrument toolkit developed showed excellent psychometric properties for measuring competence in electrocardiogram rhythm recognition.
... A telltale abnormality — called a type 1 Brugada ECG pattern — is detected by an electrocardiogram (ECG) test. Brugada syndrome is much more common in ... syndrome is an abnormal pattern on an electrocardiogram (ECG) called a type 1 Brugada ECG pattern. You ...
ECG-ViEW II, a freely accessible electrocardiogram database
Park, Man Young; Lee, Sukhoon; Jeon, Min Seok; Yoon, Dukyong; Park, Rae Woong
2017-01-01
The Electrocardiogram Vigilance with Electronic data Warehouse II (ECG-ViEW II) is a large, single-center database comprising numeric parameter data of the surface electrocardiograms of all patients who underwent testing from 1 June 1994 to 31 July 2013. The electrocardiographic data include the test date, clinical department, RR interval, PR interval, QRS duration, QT interval, QTc interval, P axis, QRS axis, and T axis. These data are connected with patient age, sex, ethnicity, comorbidities, age-adjusted Charlson comorbidity index, prescribed drugs, and electrolyte levels. This longitudinal observational database contains 979,273 electrocardiograms from 461,178 patients over a 19-year study period. This database can provide an opportunity to study electrocardiographic changes caused by medications, disease, or other demographic variables. ECG-ViEW II is freely available at http://www.ecgview.org. PMID:28437484
The electrocardiogram (ECG, EKG) is used extensively in the diagnosis of heart disease, ranging from congenital heart disease in ... and myocarditis in adults. Several different types of electrocardiogram exist.
Artifacts and noise removal in electrocardiograms using independent component analysis.
Chawla, M P S; Verma, H K; Kumar, Vinod
2008-09-26
Independent component analysis (ICA) is a novel technique capable of separating independent components from electrocardiogram (ECG) complex signals. The purpose of this analysis is to evaluate the effectiveness of ICA in removing artifacts and noise from ECG recordings. ICA is applied to remove artifacts and noise in ECG segments of either an individual ECG CSE data base file or all files. The reconstructed ECGs are compared with the original ECG signal. For the four special cases discussed, the R-Peak magnitudes of the CSE data base ECG waveforms before and after applying ICA are also found. In the results, it is shown that in most of the cases, the percentage error in reconstruction is very small. The results show that there is a significant improvement in signal quality, i.e. SNR. All the ECG recording cases dealt showed an improved ECG appearance after the use of ICA. This establishes the efficacy of ICA in elimination of noise and artifacts in electrocardiograms.
Palhares, Daniel M F; Marcolino, Milena S; Santos, Thales M M; da Silva, José L P; Gomes, Paulo R; Ribeiro, Leonardo B; Macfarlane, Peter W; Ribeiro, Antonio L P
2017-06-13
Knowledge of the normal limits of the electrocardiogram (ECG) is mandatory for establishing which patients have abnormal ECGs. No studies have assessed the reference standards for a Latin American population. Our aim was to establish the normal ranges of the ECG for pediatric and adult Brazilian primary care patients. This retrospective observational study assessed all the consecutive 12-lead digital electrocardiograms of primary care patients at least 1 year old in Minas Gerais state, Brazil, recorded between 2010 and 2015. ECGs were excluded if there were technical problems, selected abnormalities were present or patients with selected self-declared comorbidities or on drug therapy. Only the first ECG from patients with multiple ECGs was accepted. The University of Glasgow ECG analysis program was used to automatically interpret the ECGs. For each variable, the 1st, 2nd, 50th, 98th and 99th percentiles were determined and results were compared to selected studies. A total of 1,493,905 ECGs were recorded. 1,007,891 were excluded and 486.014 were analyzed. This large study provided normal values for heart rate, P, QRS and T frontal axis, P and QRS overall duration, PR and QT overall intervals and QTc corrected by Hodges, Bazett, Fridericia and Framingham formulae. Overall, the results were similar to those from other studies performed in different populations but there were differences in extreme ages and specific measurements. This study has provided reference values for Latinos of both sexes older than 1 year. Our results are comparable to studies performed in different populations.
... head, if head injury or bleeding is suspected ECG (electrocardiogram, to measure electrical activity in the heart) ... to amputation Alternative Names Intoxication - cocaine Images Electrocardiogram (ECG) References Aronson JK. Cocaine. In: Aronson JK, ed. ...
... x-ray CT scan of the chest Electrocardiogram (ECG or EKG) Echocardiogram These tests may show: Problems ... monitored for at least 24 hours. An electrocardiogram (ECG) will be done continually to check your heart ...
Computer-Interpreted Electrocardiograms: Benefits and Limitations.
Schläpfer, Jürg; Wellens, Hein J
2017-08-29
Computerized interpretation of the electrocardiogram (CIE) was introduced to improve the correct interpretation of the electrocardiogram (ECG), facilitating health care decision making and reducing costs. Worldwide, millions of ECGs are recorded annually, with the majority automatically analyzed, followed by an immediate interpretation. Limitations in the diagnostic accuracy of CIE were soon recognized and still persist, despite ongoing improvement in ECG algorithms. Unfortunately, inexperienced physicians ordering the ECG may fail to recognize interpretation mistakes and accept the automated diagnosis without criticism. Clinical mismanagement may result, with the risk of exposing patients to useless investigations or potentially dangerous treatment. Consequently, CIE over-reading and confirmation by an experienced ECG reader are essential and are repeatedly recommended in published reports. Implementation of new ECG knowledge is also important. The current status of automated ECG interpretation is reviewed, with suggestions for improvement. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
... the esophagus and the stomach. Chest x-ray ECG (electrocardiogram, or heart tracing) Fluids by IV (through ... in the airways and lungs. Chest x-ray ECG (electrocardiogram, or heart tracing) Fluids by IV (through ...
The Normal Electrocardiogram: Resting 12-Lead and Electrocardiogram Monitoring in the Hospital.
Harris, Patricia R E
2016-09-01
The electrocardiogram (ECG) is a well-established diagnostic tool extensively used in clinical settings. Knowledge of cardiac rhythm and mastery of cardiac waveform interpretation are fundamental for intensive care nurses. Recognition of the normal findings for the 12-lead ECG and understanding the significance of changes from baseline in continuous cardiac monitoring are essential steps toward ensuring safe patient care. This article highlights historical developments in electrocardiography, describes the normal resting 12-lead ECG, and discusses the need for continuous cardiac monitoring. In addition, future directions for the ECG are explored briefly. Copyright © 2016 Elsevier Inc. All rights reserved.
Fent, Graham; Gosai, Jivendra; Purva, Makani
2016-01-01
Accurate interpretation of the electrocardiogram (ECG) remains an essential skill for medical students and junior doctors. While many techniques for teaching ECG interpretation are described, no single method has been shown to be superior. This randomized control trial is the first to investigate whether teaching ECG interpretation using a computer simulator program or traditional teaching leads to improved scores in a test of ECG interpretation among medical students and postgraduate doctors immediately after and 3months following teaching. Participants' opinions of the program were assessed using a questionnaire. There were no differences in ECG interpretation test scores immediately after or 3months after teaching in the lecture or simulator groups. At present therefore, there is insufficient evidence to suggest that ECG simulator programs are superior to traditional teaching. Copyright © 2016 Elsevier Inc. All rights reserved.
[Development of a wearable electrocardiogram monitor with recognition of physical activity scene].
Wang, Zihong; Wu, Baoming; Yin, Jian; Gong, Yushun
2012-10-01
To overcome the problems of current electrocardiogram (ECG) tele-monitoring devices used for daily life, according to information fusion thought and by means of wearable technology, we developed a new type of wearable ECG monitor with the capability of physical activity recognition in this paper. The ECG monitor synchronously detected electrocardiogram signal and body acceleration signal, and recognized the scene information of physical activity, and finally determined the health status of the heart. With the advantages of accuracy for measurement, easy to use, comfort to wear, private feelings and long-term continuous in monitoring, this ECG monitor is quite fit for the heart-health monitoring in daily life.
Noninvasive recording of electrocardiogram in conscious rat: A new device.
Kumar, Pradeep; Srivastava, Pooja; Gupta, Ankit; Bajpai, Manish
2017-01-01
Electrocardiogram (ECG) is an important tool for the study of cardiac electrophysiology both in human beings and experimental animals. Existing methods of ECG recording in small animals like rat have several limitations and ECG recordings of the anesthetized rat lack validity for heart rate (HR) variability analysis. The aim of the present study was to validate the ECG data from new device with ECG of anesthetized rat. The ECG was recorded on student's physiograph (BioDevice, Ambala) and suitable coupler and electrodes in six animals first by the newly developed device in conscious state and second in anesthetized state (stabilized technique). The data obtained were analyzed using unpaired t -test showed no significant difference ( P < 0.05) in QTc, QRS, and HR recorded by new device and established device in rats. No previous study describes a similar ECG recording in conscious state of rats. Thus, the present method may be a most physiological and inexpensive alternative to other methods. In this study, the animals were not restrained; they were just secured and represent a potential strength of the study.
[Advances of portable electrocardiogram monitor design].
Ding, Shenping; Wang, Yinghai; Wu, Weirong; Deng, Lingli; Lu, Jidong
2014-06-01
Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.
[Study for portable dynamic ECG monitor and recorder].
Yang, Pengcheng; Li, Yongqin; Chen, Bihua
2012-09-01
This Paper presents a portable dynamic ECG monitor system based on MSP430F149 microcontroller. The electrocardiogram detecting system consists of ECG detecting circuit, man-machine interaction module, MSP430F149 and upper computer software. The ECG detecting circuit including a preamplifier, second-order Butterworth low-pass filter, high-pass filter, and 50Hz trap circuit to detects electrocardiogram and depresses various kinds of interference effectively. A microcontroller is used to collect three channel analog signals which can be displayed on TFT LCD. A SD card is used to record real-time data continuously and implement the FTA16 file system. In the end, a host computer system interface is also designed to analyze the ECG signal and the analysis results can provide diagnosis references to clinical doctors.
NASA Astrophysics Data System (ADS)
Yan, Hua-Wen; Huang, Xiao-Lin; Zhao, Ying; Si, Jun-Feng; Liu, Tie-Bing; Liu, Hong-Xing
2014-11-01
A series of experiments are conducted to confirm whether the vectors calculated for an early section of a continuous non-invasive fetal electrocardiogram (fECG) recording can be directly applied to subsequent sections in order to reduce the computation required for real-time monitoring. Our results suggest that it is generally feasible to apply the initial optimal maternal and fetal ECG combination vectors to extract the fECG and maternal ECG in subsequent recorded sections.
Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System
Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk
2016-01-01
In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user’s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user’s high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user’s daily smartphone use. PMID:26978364
Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System.
Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk
2016-03-11
In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user's ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user's high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user's daily smartphone use.
Use of the Surface Electrocardiogram to Define the Nature of Challenging Arrhythmias.
Singh, David K; Peter, C Thomas
2016-03-01
Despite unprecedented advances in technology, the electrocardiogram (ECG) remains essential to the practice of modern electrophysiology. Since its emergence at the turn of the nineteenth century, the form of the ECG has changed little. What has changed is our ability to understand the complex mechanisms that underlie various arrhythmias. In this article, the authors review several important principles of ECG interpretation by providing illustrative tracings. The authors also highlight several important concepts that be can used in ECG analysis. There are several fundamental principles that should be considered in ECG interpretation. Copyright © 2016 Elsevier Inc. All rights reserved.
Chung, Seungmin; Yi, Joohee
2013-01-01
Electromagnetic interference (EMI) can affect various medical devices. Herein, we report the case of EMI from wireless local area network (WLAN) on an electrocardiogram (ECG) monitoring system. A patient who had a prior myocardial infarction participated in the cardiac rehabilitation program in the sports medicine center of our hospital under the wireless ECG monitoring system. After WLAN was installed, wireless ECG monitoring system failed to show a proper ECG signal. ECG signal was distorted when WLAN was turned on, but it was normalized after turning off the WLAN. PMID:23613696
A Review on the Nonlinear Dynamical System Analysis of Electrocardiogram Signal
Mohapatra, Biswajit
2018-01-01
Electrocardiogram (ECG) signal analysis has received special attention of the researchers in the recent past because of its ability to divulge crucial information about the electrophysiology of the heart and the autonomic nervous system activity in a noninvasive manner. Analysis of the ECG signals has been explored using both linear and nonlinear methods. However, the nonlinear methods of ECG signal analysis are gaining popularity because of their robustness in feature extraction and classification. The current study presents a review of the nonlinear signal analysis methods, namely, reconstructed phase space analysis, Lyapunov exponents, correlation dimension, detrended fluctuation analysis (DFA), recurrence plot, Poincaré plot, approximate entropy, and sample entropy along with their recent applications in the ECG signal analysis. PMID:29854361
A Review on the Nonlinear Dynamical System Analysis of Electrocardiogram Signal.
Nayak, Suraj K; Bit, Arindam; Dey, Anilesh; Mohapatra, Biswajit; Pal, Kunal
2018-01-01
Electrocardiogram (ECG) signal analysis has received special attention of the researchers in the recent past because of its ability to divulge crucial information about the electrophysiology of the heart and the autonomic nervous system activity in a noninvasive manner. Analysis of the ECG signals has been explored using both linear and nonlinear methods. However, the nonlinear methods of ECG signal analysis are gaining popularity because of their robustness in feature extraction and classification. The current study presents a review of the nonlinear signal analysis methods, namely, reconstructed phase space analysis, Lyapunov exponents, correlation dimension, detrended fluctuation analysis (DFA), recurrence plot, Poincaré plot, approximate entropy, and sample entropy along with their recent applications in the ECG signal analysis.
The history, hotspots, and trends of electrocardiogram.
Yang, Xiang-Lin; Liu, Guo-Zhen; Tong, Yun-Hai; Yan, Hong; Xu, Zhi; Chen, Qi; Liu, Xiang; Zhang, Hong-Hao; Wang, Hong-Bo; Tan, Shao-Hua
2015-07-01
The electrocardiogram (ECG) has broad applications in clinical diagnosis and prognosis of cardiovascular disease. Many researchers have contributed to its progressive development. To commemorate those pioneers, and to better study and promote the use of ECG, we reviewed and present here a systematic introduction about the history, hotspots, and trends of ECG. In the historical part, information including the invention, improvement, and extensive applications of ECG, such as in long QT syndrome (LQTS), angina, and myocardial infarction (MI), are chronologically presented. New technologies and applications from the 1990s are also introduced. In the second part, we use the bibliometric analysis method to analyze the hotspots in the field of ECG-related research. By using total citations and year-specific total citations as our main criteria, four key hotspots in ECG-related research were identified from 11 articles, including atrial fibrillation, LQTS, angina and MI, and heart rate variability. Recent studies in those four areas are also reported. In the final part, we discuss the future trends concerning ECG-related research. The authors believe that improvement of the ECG instrumentation, big data mining for ECG, and the accuracy of diagnosis and application will be areas of continuous concern.
The history, hotspots, and trends of electrocardiogram
Yang, Xiang-Lin; Liu, Guo-Zhen; Tong, Yun-Hai; Yan, Hong; Xu, Zhi; Chen, Qi; Liu, Xiang; Zhang, Hong-Hao; Wang, Hong-Bo; Tan, Shao-Hua
2015-01-01
The electrocardiogram (ECG) has broad applications in clinical diagnosis and prognosis of cardiovascular disease. Many researchers have contributed to its progressive development. To commemorate those pioneers, and to better study and promote the use of ECG, we reviewed and present here a systematic introduction about the history, hotspots, and trends of ECG. In the historical part, information including the invention, improvement, and extensive applications of ECG, such as in long QT syndrome (LQTS), angina, and myocardial infarction (MI), are chronologically presented. New technologies and applications from the 1990s are also introduced. In the second part, we use the bibliometric analysis method to analyze the hotspots in the field of ECG-related research. By using total citations and year-specific total citations as our main criteria, four key hotspots in ECG-related research were identified from 11 articles, including atrial fibrillation, LQTS, angina and MI, and heart rate variability. Recent studies in those four areas are also reported. In the final part, we discuss the future trends concerning ECG-related research. The authors believe that improvement of the ECG instrumentation, big data mining for ECG, and the accuracy of diagnosis and application will be areas of continuous concern. PMID:26345622
An introduction to the reading of electrocardiograms.
Woodrow, P
This article introduces the basic principles of reading electrocardiograms (ECGs) for nurses who are unfamiliar with reading them. For more experienced practitioners there are a number of useful articles and books (e.g. Hampton, 1992a, b) that will help further their knowledge. The ECG records cardiac electrical activity as a graph; interpretation is illustrated here by sinus rhythm. A single ECG lead (lead II) is used throughout this article. Atrial fibrillation is described to show a contrasting dysrhythmia. Specific nursing care is suggested for patients being monitored or having ECGs taken.
Evaluation of an electrocardiogram on QR code.
Nakayama, Masaharu; Shimokawa, Hiroaki
2013-01-01
An electrocardiogram (ECG) is an indispensable tool to diagnose cardiac diseases, such as ischemic heart disease, myocarditis, arrhythmia, and cardiomyopathy. Since ECG patterns vary depend on patient status, it is also used to monitor patients during treatment and comparison with ECGs with previous results is important for accurate diagnosis. However, the comparison requires connection to ECG data server in a hospital and the availability of data connection among hospitals is limited. To improve the portability and availability of ECG data regardless of server connection, we here introduce conversion of ECG data into 2D barcodes as text data and decode of the QR code for drawing ECG with Google Chart API. Fourteen cardiologists and six general physicians evaluated the system using iPhone and iPad. Overall, they were satisfied with the system in usability and accuracy of decoded ECG compared to the original ECG. This new coding system may be useful in utilizing ECG data irrespective of server connections.
The electrocardiogram signal of Seba's short-tailed bat, Carollia perspicillata.
Mihova, Diana; Hechavarría, Julio C
2016-07-01
A number of studies have successfully used electrocardiogram (ECG) signals to characterize complex physiological phenomena such as associative learning in bats. However, at present, no thorough characterization of the structure of ECG signals is available for these animals. The aim of the present study was to quantitatively characterize features of the ECG signals in the bat species Carollia perspicillata, a species that is commonly used in neuroethology studies. Our results show that the ECG signals of C. perspicillata follow the typical mammalian pattern, in that they are composed by a P wave, QRS complex and a T wave. Peak-to-peak amplitudes in the bats' ECG signals were larger in measuring configurations in which one of the electrodes was attached to the right thumb. In addition, large differences in the instantaneous heart rate (HR) distributions were observed between ketamine/xylazine anesthetized and awake bats. Ketamine/xylazine might target the neural circuits that control HR, therefore, instantaneous HR measurements should only be used as physiological marker in awake animals.
Using the 12-Lead Electrocardiogram in the Care of Athletic Patients.
Yeo, Tee Joo; Sharma, Sanjay
2016-11-01
This article summarizes the role of the 12-lead electrocardiogram (ECG) for the clinical care of athletes, with particular reference to the influence of age, gender, ethnicity, and type of sport on the appearance of the ECG, and its role in differentiating physiologic exercise-related changes from pathologic conditions implicated in sudden cardiac death (SCD). The article also explores the potential role of the ECG in detecting athletes at risk of SCD. In addition, the article reviews the evolution of ECG interpretation criteria and emphasizes the limitations of the ECG as well as the potential for future research. Copyright © 2016 Elsevier Inc. All rights reserved.
Ker, James
2012-07-12
During the past century the electrocardiogram (ECG) has established itself as an integral part of the cardiovascular examination. Since the first direct recordings of cardiac potentials by Waller in 1887, to the invention of the string galvanometer by Willem Einthoven in 1901, to use in the clinic by 1910, the electrocardiogram has become the most widely used clinical tool in the diagnosis of virtually every type of heart disease. Currently up to 20 million ECGs are performed annually in the United States alone. However, in this era of readily available echocardiography, an important caveat in the interpretation of the electrocardiogram has emerged: variants of intracardiac structures which might mimic disease on the ECG. In this perspective various structural variants of intracardiac structures, specifically variants of papillary muscles and subaortic muscular bands, will be shown, together with their associated electrocardiographic changes, mimicking disease. It is concluded that in this era of readily available echocardiography, the electrocardiogram should be interpreted echocardiographically in instances where intricate variations are seen on the surface electrocardiogram. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Evaluation of agreement between temporal series obtained from electrocardiogram and pulse wave.
NASA Astrophysics Data System (ADS)
Leikan, GM; Rossi, E.; Sanz, MCuadra; Delisle Rodríguez, D.; Mántaras, MC; Nicolet, J.; Zapata, D.; Lapyckyj, I.; Siri, L. Nicola; Perrone, MS
2016-04-01
Heart rate variability allows to study the cardiovascular autonomic nervous system modulation. Usually, this signal is obtained from the electrocardiogram (ECG). A simpler method for recording the pulse wave (PW) is by means of finger photoplethysmography (PPG), which also provides information about the duration of the cardiac cycle. In this study, the correlation and agreement between the time series of the intervals between heartbeats obtained from the ECG with those obtained from the PPG, were studied. Signals analyzed were obtained from young, healthy and resting subjects. For statistical analysis, the Pearson correlation coefficient and the Bland and Altman limits of agreement were used. Results show that the time series constructed from the PW would not replace the ones obtained from ECG.
A Precise Drunk Driving Detection Using Weighted Kernel Based on Electrocardiogram.
Wu, Chung Kit; Tsang, Kim Fung; Chi, Hao Ran; Hung, Faan Hei
2016-05-09
Globally, 1.2 million people die and 50 million people are injured annually due to traffic accidents. These traffic accidents cost $500 billion dollars. Drunk drivers are found in 40% of the traffic crashes. Existing drunk driving detection (DDD) systems do not provide accurate detection and pre-warning concurrently. Electrocardiogram (ECG) is a proven biosignal that accurately and simultaneously reflects human's biological status. In this letter, a classifier for DDD based on ECG is investigated in an attempt to reduce traffic accidents caused by drunk drivers. At this point, it appears that there is no known research or literature found on ECG classifier for DDD. To identify drunk syndromes, the ECG signals from drunk drivers are studied and analyzed. As such, a precise ECG-based DDD (ECG-DDD) using a weighted kernel is developed. From the measurements, 10 key features of ECG signals were identified. To incorporate the important features, the feature vectors are weighted in the customization of kernel functions. Four commonly adopted kernel functions are studied. Results reveal that weighted feature vectors improve the accuracy by 11% compared to the computation using the prime kernel. Evaluation shows that ECG-DDD improved the accuracy by 8% to 18% compared to prevailing methods.
Improvement of electrocardiogram by empirical wavelet transform
NASA Astrophysics Data System (ADS)
Chanchang, Vikanda; Kumchaiseemak, Nakorn; Sutthiopad, Malee; Luengviriya, Chaiya
2017-09-01
Electrocardiogram (ECG) is a crucial tool in the detection of cardiac arrhythmia. It is also often used in a routine physical exam, especially, for elderly people. This graphical representation of electrical activity of heart is obtained by a measurement of voltage at the skin; therefore, the signal is always contaminated by noise from various sources. For a proper interpretation, the quality of the ECG should be improved by a noise reduction. In this article, we present a study of a noise filtration in the ECG by using an empirical wavelet transform (EWT). Unlike the traditional wavelet method, EWT is adaptive since the frequency spectrum of the ECG is taken into account in the construction of the wavelet basis. We show that the signal-to-noise ratio increases after the noise filtration for different noise artefacts.
Pit-a-Pat: A Smart Electrocardiogram System for Detecting Arrhythmia.
Park, Juyoung; Lee, Kuyeon; Kang, Kyungtae
2015-10-01
Electrocardiogram (ECG) telemonitoring is one of the most promising applications of medical telemetry. However, previous approaches to ECG telemonitoring have largely relied on public databases of ECG results. In this article we propose a smart ECG system called Pit-a-Pat, which extracts features from ECG signals and detects arrhythmia. It is designed to run on an Android™ (Google, Mountain View, CA) device, without requiring modifications to other software. We implemented the Pit-a-Pat system using a commercial ECG device, and the experimental results demonstrate the effectiveness and accuracy of Pit-a-Pat for monitoring the ECG signal and analyzing the cardiac activity of a mobile patient. The proposed system allows monitoring of cardiac activity with automatic analysis, thereby providing a convenient, inexpensive, and ubiquitous adjunct to personal healthcare.
Coronary anatomy and the 12-lead electrocardiogram: how to tell who is hurting.
Phillips, R A
1997-12-01
Knowledge of how the coronary arteries, cardiac topography, and the 12-lead electrocardiogram (ECG) link together is imperative if the electrical tracing is to be interpreted correctly. Advanced practice nurses not familiar with the ECG may be intimidated by attempts to identify the disease process of myocardial infarctions. This article reviews coronary anatomy and cardiac topography and then links them to the 12-lead ECG for determining areas of myocardial ischemia, injury, and death.
Prevalence of Cardiovascular Disorders Among Iranian Elite Athletes.
Salehi, Shahin; Moradi Shahpar, Farhad; Norouzi, Gholamreza; Ghazalian, Farshad; Poursaid Esfehani, Mehrshad; Abedi Yekta, Amir Hosein
2016-06-01
Athletes' health is an important issue and for promoting it, pre-participation examination (PPE) is widely performed by responsible bodies around the world. This study was to determine prevalence of cardiovascular disorders among athletes participating in the Asian games and answering the question whether the electrocardiogram (ECG) is a necessary part of pre-participation examination (PPE) for prevention of sudden cardiac death. All athletes participated at Asian games came to sports medicine federation for a PPE including a comprehensive questionnaire, physical examination and ECG. In this retrospective study all profiles of 338 athletes have been studied as well as their electrocardiograms. Multiple logistic regressions as well as Firth's bias reduction were used with R statistical software and SPSS. For predicting the changes in ECG, receiver operating characteristic (ROC) curve has done. Among 388 athletes, 80 (20.6%) were female and 308 (79.4%) male with mean age of 23.2 + 8 years. Nine athletes (2.3%) were smokers, 28 of them (7.2%) experienced chest pain and discomfort, 45 of them (13.3%) had palpitations and 28 (7.2%) had history of anemia. Study of their electrocardiograms showed that long Q-T interval was not seen for anyone, but evidence of left ventricular hypertrophy was seen in 12 (3.1%), inverted T wave in 6 (1.5%), and right bundle branch block in 45 (13.3%). PPE provides very important information of athletes' health. This study has shown that there was not any significant relation between current examination and electrocardiogram changes but regarding the ECG changes we recommend it as a routine part of PPE.
A markup language for electrocardiogram data acquisition and analysis (ecgML)
Wang, Haiying; Azuaje, Francisco; Jung, Benjamin; Black, Norman
2003-01-01
Background The storage and distribution of electrocardiogram data is based on different formats. There is a need to promote the development of standards for their exchange and analysis. Such models should be platform-/ system- and application-independent, flexible and open to every member of the scientific community. Methods A minimum set of information for the representation and storage of electrocardiogram signals has been synthesised from existing recommendations. This specification is encoded into an XML-vocabulary. The model may aid in a flexible exchange and analysis of electrocardiogram information. Results Based on advantages of XML technologies, ecgML has the ability to present a system-, application- and format-independent solution for representation and exchange of electrocardiogram data. The distinction between the proposal developed by the U.S Food and Drug Administration and ecgML model is given. A series of tools, which aim to facilitate ecgML-based applications, are presented. Conclusions The models proposed here can facilitate the generation of a data format, which opens ways for better and clearer interpretation by both humans and machines. Its structured and transparent organisation will allow researchers to expand and test its capabilities in different application domains. The specification and programs for this protocol are publicly available. PMID:12735790
Terho, Henri K; Tikkanen, Jani T; Kenttä, Tuomas V; Junttila, M Juhani; Aro, Aapo L; Anttonen, Olli; Kerola, Tuomas; Rissanen, Harri A; Knekt, Paul; Reunanen, Antti; Huikuri, Heikki V
2016-11-01
The long-term prognostic value of a standard 12-lead electrocardiogram (ECG) for predicting cardiac events in apparently healthy middle-aged subjects is not well defined. A total of 9511 middle-aged subjects (mean age 43 ± 8.2 years, 52% males) without a known cardiac disease and with a follow-up 40 years were included in the study. Fatal and non-fatal cardiac events were collected from the national registries. The predictive value of ECG was separately analyzed for 10 and 30 years. Major ECG abnormalities were classified according to the Minnesota code. Subjects with major ECG abnormalities (N = 1131) had an increased risk of cardiac death after 10-years (adjusted hazard ratio [HR] 1.7; 95% confidence interval [95% CI], 1.1-2.5, p = 0.009) and 30-years of follow-up (HR 1.3, 95% CI, 1.1-1.5, p < 0.001). Model discrimination measured with the C-index showed only a minor improvement with the inclusion of ECG abnormalities: 0.851 versus 0.853 and 0.742 versus 0.743 for 10- and 30-year follow-up, respectively. ECG did not predict non-fatal cardiac events after 10-years or 30-years of follow-up. Major ECG abnormalities are associated with an increased risk of short and long-term cardiac mortality in middle-aged subjects. However, the improvement in discrimination between subjects with and without fatal cardiac events was marginal with abnormal ECG. Abnormalities observed on 12-lead electrocardiogram are shown to have prognostic significance for cardiac events in elderly subjects without known cardiac disease. Our results suggest that ECG abnormalities increase the risk of fatal cardiac events also in middle-aged healthy subjects.
A Fixed-Lag Kalman Smoother to Filter Power Line Interference in Electrocardiogram Recordings.
Warmerdam, G J J; Vullings, R; Schmitt, L; Van Laar, J O E H; Bergmans, J W M
2017-08-01
Filtering power line interference (PLI) from electrocardiogram (ECG) recordings can lead to significant distortions of the ECG and mask clinically relevant features in ECG waveform morphology. The objective of this study is to filter PLI from ECG recordings with minimal distortion of the ECG waveform. In this paper, we propose a fixed-lag Kalman smoother with adaptive noise estimation. The performance of this Kalman smoother in filtering PLI is compared to that of a fixed-bandwidth notch filter and several adaptive PLI filters that have been proposed in the literature. To evaluate the performance, we corrupted clean neonatal ECG recordings with various simulated PLI. Furthermore, examples are shown of filtering real PLI from an adult and a fetal ECG recording. The fixed-lag Kalman smoother outperforms other PLI filters in terms of step response settling time (improvements that range from 0.1 to 1 s) and signal-to-noise ratio (improvements that range from 17 to 23 dB). Our fixed-lag Kalman smoother can be used for semi real-time applications with a limited delay of 0.4 s. The fixed-lag Kalman smoother presented in this study outperforms other methods for filtering PLI and leads to minimal distortion of the ECG waveform.
NASA Astrophysics Data System (ADS)
Mishra, Puneet; Singla, Sunil Kumar
2013-01-01
In the modern world of automation, biological signals, especially Electroencephalogram (EEG) and Electrocardiogram (ECG), are gaining wide attention as a source of biometric information. Earlier studies have shown that EEG and ECG show versatility with individuals and every individual has distinct EEG and ECG spectrum. EEG (which can be recorded from the scalp due to the effect of millions of neurons) may contain noise signals such as eye blink, eye movement, muscular movement, line noise, etc. Similarly, ECG may contain artifact like line noise, tremor artifacts, baseline wandering, etc. These noise signals are required to be separated from the EEG and ECG signals to obtain the accurate results. This paper proposes a technique for the removal of eye blink artifact from EEG and ECG signal using fixed point or FastICA algorithm of Independent Component Analysis (ICA). For validation, FastICA algorithm has been applied to synthetic signal prepared by adding random noise to the Electrocardiogram (ECG) signal. FastICA algorithm separates the signal into two independent components, i.e. ECG pure and artifact signal. Similarly, the same algorithm has been applied to remove the artifacts (Electrooculogram or eye blink) from the EEG signal.
Global electrical heterogeneity as a predictor of cardiovascular mortality in men and women.
Lipponen, Jukka A; Kurl, Sudhir; Laukkanen, Jari A
2018-06-02
The aim of this study was to investigate the contribution of depolarization and repolarization abnormalities, specially abnormalities in global electrical heterogeneity of heart in cardiovascular disease (CVD) and all-cause mortality. Eight hundred and forty men and 911 women, average age of 63 years participated in this study with average follow-up was 14 years. Six electrocardiogram/vector electrocardiogram (ECG/VECG) markers QRS-duration, QTc-interval, QRST-angle, sum of absolute QRST integral (SAI QRST), T-wave roundness, and TV1-amplitude were estimated from VECG measurements. Hazard ratios (HRs) for CVD events (164 deaths) and all-cause mortality (383 deaths) for ECG parameters were calculated. Electrocardiogram or vector electrocardiogram parameter models adjusted for risk clinical factors showed that strongest predictors for CVD mortality were QRST-angle (HR 3.44, 95% confidence interval 2.12-5.36), QTc-interval (2.72, 1.73-4.29), and T-wave roundness (2.09, 1.26-3.46) among men. The strongest ECG/VECG parameters for CVD death were QRST-angle (2.47, 1.37-4.45), SAI QRST (2.37, 1.23-4.6), and QTc-interval (2.15, 1.16-4.01) among female participants. Multivariable adjusted models revealed that strongest independent ECG predictors for CVD death were QRST-angle, QTc-interval, resting heart rate, and T-roundness for men, QRST-angle and SAI QRST for women. QRST-angle, QTc-interval, resting heart rate, and T-roundness were associated with all-cause mortality in male population, although none of the ECG/VECG parameters predicted all-cause mortality among women. Characteristics of global electrical heterogeneity QRST-angle and QTc-interval in men and QRST-angle and SAI QRST among females were strong and independent risk markers for cardiovascular mortality. These parameters provide new additional ECG tools for cardiovascular risk stratification.
Yang, Meixue; Liu, Bin; Zhao, Miaomiao; Li, Fan; Wang, Guoqing; Zhou, Fengfeng
2013-01-01
Although electrocardiogram (ECG) fluctuates over time and physical activity, some of its intrinsic measurements serve well as biometric features. Considering its constant availability and difficulty in being faked, the ECG signal is becoming a promising factor for biometric authentication. The majority of the currently available algorithms only work well on healthy participants. A novel normalization and interpolation algorithm is proposed to convert an ECG signal into multiple template cycles, which are comparable between any two ECGs, no matter the sampling rates or health status. The overall accuracies reach 100% and 90.11% for healthy participants and cardiovascular disease (CVD) patients, respectively.
Zhao, Miaomiao; Li, Fan; Wang, Guoqing; Zhou, Fengfeng
2013-01-01
Although electrocardiogram (ECG) fluctuates over time and physical activity, some of its intrinsic measurements serve well as biometric features. Considering its constant availability and difficulty in being faked, the ECG signal is becoming a promising factor for biometric authentication. The majority of the currently available algorithms only work well on healthy participants. A novel normalization and interpolation algorithm is proposed to convert an ECG signal into multiple template cycles, which are comparable between any two ECGs, no matter the sampling rates or health status. The overall accuracies reach 100% and 90.11% for healthy participants and cardiovascular disease (CVD) patients, respectively. PMID:23977063
Digitization of Electrocardiogram From Telemetry Prior to In-hospital Cardiac Arrest: A Pilot Study.
Attin, Mina; Wang, Lu; Soroushmehr, S M Reza; Lin, Chii-Dean; Lemus, Hector; Spadafore, Maxwell; Najarian, Kayvan
2016-03-01
Analyzing telemetry electrocardiogram (ECG) data over an extended period is often time-consuming because digital records are not widely available at hospitals. Investigating trends and patterns in the ECG data could lead to establishing predictors that would shorten response time to in-hospital cardiac arrest (I-HCA). This study was conducted to validate a novel method of digitizing paper ECG tracings from telemetry systems in order to facilitate the use of heart rate as a diagnostic feature prior to I-HCA. This multicenter study used telemetry to investigate full-disclosure ECG papers of 44 cardiovascular patients obtained within 1 hr of I-HCA with initial rhythms of pulseless electrical activity and asystole. Digital ECGs were available for seven of these patients. An algorithm to digitize the full-disclosure ECG papers was developed using the shortest path method. The heart rate was measured manually (averaging R-R intervals) for ECG papers and automatically for digitized and digital ECGs. Significant correlations were found between manual and automated measurements of digitized ECGs (p < .001) and between digitized and digital ECGs (p < .001). Bland-Altman methods showed bias = .001 s, SD = .0276 s, lower and upper 95% limits of agreement for digitized and digital ECGs = .055 and -.053 s, and percentage error = 0.22%. Root mean square (rms), percentage rms difference, and signal to noise ratio values were in acceptable ranges. The digitization method was validated. Digitized ECG provides an efficient and accurate way of measuring heart rate over an extended period of time. © The Author(s) 2015.
Design of portable electrocardiogram device using DSO138
NASA Astrophysics Data System (ADS)
Abuzairi, Tomy; Matondang, Josef Stevanus; Purnamaningsih, Retno Wigajatri; Basari, Ratnasari, Anita
2018-02-01
Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.
Cardiac Computed Tomography (Multidetector CT, or MDCT)
... other tests, such as chest X-rays , electrocardiograms (ECG) , echocardiograms (echocardiography) , or stress tests , don’t give ... be attached to your chest to monitor your ECG. The ECG is also needed to help the ...
WaveformECG: A Platform for Visualizing, Annotating, and Analyzing ECG Data
Winslow, Raimond L.; Granite, Stephen; Jurado, Christian
2017-01-01
The electrocardiogram (ECG) is the most commonly collected data in cardiovascular research because of the ease with which it can be measured and because changes in ECG waveforms reflect underlying aspects of heart disease. Accessed through a browser, WaveformECG is an open source platform supporting interactive analysis, visualization, and annotation of ECGs. PMID:28642673
Electrocardiogram Changes with Acute Alcohol Intoxication: A Systematic Review.
Raheja, Hitesh; Namana, Vinod; Chopra, Kirti; Sinha, Ankur; Gupta, Sushilkumar Satish; Kamholz, Stephan; Moskovits, Norbert; Shani, Jacob; Hollander, Gerald
2018-01-01
Acute alcohol intoxication has been associated with cardiac arrhythmias but the electrocardiogram (ECG) changes associated with acute alcohol intoxication are not well defined in the literature. Highlight the best evidence regarding the ECG changes associated with acute alcohol intoxication in otherwise healthy patients and the pathophysiology of the changes. A literature search was carried out; 4 studies relating to ECG changes with acute alcohol intoxication were included in this review. Of the total 141 patients included in the review, 90 (63.8%) patients had P-wave prolongation, 80 (56%) patients had QTc prolongation, 19 (13.5%) patients developed T-wave abnormalities, 10 (7%) patients had QRS complex prolongation, 3 (2.12%) patients developed ST-segment depressions. The most common ECG changes associated with acute alcohol intoxication are (in decreasing order of frequency) P-wave and QTc prolongation, followed by T-wave abnormalities and QRS complex prolongation. Mostly, these changes are completely reversible.
A novel biometric authentication approach using ECG and EMG signals.
Belgacem, Noureddine; Fournier, Régis; Nait-Ali, Amine; Bereksi-Reguig, Fethi
2015-05-01
Security biometrics is a secure alternative to traditional methods of identity verification of individuals, such as authentication systems based on user name and password. Recently, it has been found that the electrocardiogram (ECG) signal formed by five successive waves (P, Q, R, S and T) is unique to each individual. In fact, better than any other biometrics' measures, it delivers proof of subject's being alive as extra information which other biometrics cannot deliver. The main purpose of this work is to present a low-cost method for online acquisition and processing of ECG signals for person authentication and to study the possibility of providing additional information and retrieve personal data from an electrocardiogram signal to yield a reliable decision. This study explores the effectiveness of a novel biometric system resulting from the fusion of information and knowledge provided by ECG and EMG (Electromyogram) physiological recordings. It is shown that biometrics based on these ECG/EMG signals offers a novel way to robustly authenticate subjects. Five ECG databases (MIT-BIH, ST-T, NSR, PTB and ECG-ID) and several ECG signals collected in-house from volunteers were exploited. A palm-based ECG biometric system was developed where the signals are collected from the palm of the subject through a minimally intrusive one-lead ECG set-up. A total of 3750 ECG beats were used in this work. Feature extraction was performed on ECG signals using Fourier descriptors (spectral coefficients). Optimum-Path Forest classifier was used to calculate the degree of similarity between individuals. The obtained results from the proposed approach look promising for individuals' authentication.
Electrocardiograms with pacemakers: accuracy of computer reading.
Guglin, Maya E; Datwani, Neeta
2007-04-01
We analyzed the accuracy with which a computer algorithm reads electrocardiograms (ECGs) with electronic pacemakers (PMs). Electrocardiograms were screened for the presence of electronic pacing spikes. Computer-derived interpretations were compared with cardiologists' readings. Computer-drawn interpretations required revision by cardiologists in 61.3% of cases. In 18.4% of cases, the ECG reading algorithm failed to recognize the presence of a PM. The misinterpretation of paced beats as intrinsic beats led to multiple secondary errors, including myocardial infarctions in varying localization. The most common error in computer reading was the failure to identify an underlying rhythm. This error caused frequent misidentification of the PM type, especially when the presence of normal sinus rhythm was not recognized in a tracing with a DDD PM tracking the atrial activity. The increasing number of pacing devices, and the resulting number of ECGs with pacing spikes, mandates the refining of ECG reading algorithms. Improvement is especially needed in the recognition of the underlying rhythm, pacing spikes, and mode of pacing.
Ng, Choon Ta; Chee, Tek Siong; Ling, Lee Fong; Lee, Yian Ping; Ching, Chi Keong; Chua, Terrance S J; Cheok, Christopher; Ong, Hean Yee
2011-06-01
Hypertrophic cardiomyopathy is a leading cause of sudden cardiac death (SCD) in young people in the USA. Pre-participation screening for athletes might reduce the incidence of SCD. In Singapore, military service is compulsory for all young able-bodied male citizens. The Singapore Armed Forces Electrocardiogram and Echocardiogram (SAFE) pre-participation screening protocol based on the Italian programme was introduced. This study evaluates the prevalence of hypertrophic cardiomyopathy (HCM) in a young male South-East Asian population. From October 2008 to May 2009, all male military conscripts underwent pre-participation screening. For all conscripts whose electrocardiogram (ECG) findings fulfilled any of these pre-specified criteria (Group A), direct referral for a transthoracic echocardiogram was mandatory. Conscripts with ECG findings other than pre-specified criteria (e.g. T-wave inversions, repolarization abnormalities) were referred for secondary screening by cardiologists (Group B), which could include echocardiography. Out of 18 476 subjects screened during the study period, 988 (5.3%) subjects were fast tracked for echocardiogram (Group A). Of them, there were three (0.3%) cases with severe abnormalities; there was one case each of HCM, bicuspid aortic valve with significant aortic valve regurgitation, and atrial septal defect with right ventricular systolic dysfunction. The patient with HCM had left axis deviation on ECG. None of the 215 patients who underwent echocardiography following cardiology consult (Group B) had HCM. The prevalence of HCM in our young male population (mean age 19.5, range 16-27) using an ECG-based screening protocol was 0.005%; this appeared lower than published data from other geographical cohorts. Possible explanations include a later age of phenotypic manifestation in our population, limitations of the ECG criteria for screening, or a truly lower prevalence of HCM. More population-based longitudinal studies would be needed to ascertain the true prevalence of HCM in our South-East Asian population.
A survey of paediatricians on the use of electrocardiogram for pre-participation sports screening.
Patel, Angira; Webster, Gregory; Ward, Kendra; Lantos, John
2017-07-01
Aim The aim of the present study was to determine general paediatrician knowledge, practices, and attitudes towards electrocardiogram (ECG) screening in school athletes during pre-participation screening exam (PPSE). Paediatricians affiliated with a tertiary children's hospital completed a survey about ECGs for PPSE. In total, 205/498 (41%) responded; 92% of the paediatricians did not include an ECG as part of PPSE; 56% were aware of a case in which a student athlete in their own community had died of sudden unexplained death; 4% had an athlete in their practice die. Only 16% of paediatricians perform all 12 American Heart Association recommended elements of the PPSE. If any of these screening elements are abnormal, 69% obtain an ECG, 36% an echocardiogram, and 30% restrict patients from sports activity; 73% of them refer the patient to a cardiologist. Most of the general paediatricians surveyed did not currently perform ECGs for PPSE. In addition, there was a low rate of adherence to performing the 12 screening elements recommended by the American Heart Association. They have trouble obtaining timely, accurate ECG interpretations, worry about potential unnecessary exercise restrictions, and cost-effectiveness. The practical hurdles to ECG implementation emphasise the need for a fresh look at PPSE, and not just ECG screening. Improvements in ECG performance/interpretation would be necessary for ECGs to be a useful part of PPSE.
2014-11-01
networks were trained to predict an individual’s electrocardiogram (ECG) and arterial blood pressure ( ABP ) waveform data, which can potentially help...various ESN architectures for prediction tasks, and establishes the benefits of using ESN architecture designs for predicting ECG and ABP waveforms...arterial blood pressure ( ABP ) waveforms immediately prior to the machine generated alarms. When tested, the algorithm suppressed approximately 59.7
Fang, Qiang; Mahmoud, Seedahmed S; Yan, Jiayong; Li, Hui
2016-11-23
For this investigation, we studied the effects of extremely low frequency pulse electromagnetic fields (ELF-PEMF) on the human cardiac signal. Electrocardiograms (ECGs) of 22 healthy volunteers before and after a short duration of ELF-PEMF exposure were recorded. The experiment was conducted under single-blind conditions. The root mean square (RMS) value of the recorded data was considered as comparison criteria. We also measured and analysed four important ECG time intervals before and after ELF-PEMF exposure. Results revealed that the RMS value of the ECG recordings from 18 participants (81.8% of the total participants) increased with a mean value of 3.72%. The increase in ECG voltage levels was then verified by a second experimental protocol with a control exposure. In addition to this, we used hyperbolic T-distributions (HTD) in the analysis of ECG signals to verify the change in the RR interval. It was found that there were small shifts in the frequency-domain signal before and after EMF exposure. This shift has an influence on all frequency components of the ECG signals, as all spectrums were shifted. It is shown from this investigation that a short time exposure to ELF-PEMF can affect the properties of ECG signals. Further study is needed to consolidate this finding and discover more on the biological effects of ELF-PEMF on human physiological processes.
Kim, Diana H; Verdino, Ralph J
To define clinical correlates of low voltage isolated to precordial leads on the surface electrocardiogram (ECG). Low voltage (V) on the ECG is defined as QRS V<5mm in all limb leads and <10mm in all precordial leads. The diagnostic use of ECGs with low voltage isolated to the precordial leads with normal limb lead voltages is unclear. Twelve-lead ECGs with QRS V>5mm in one or more limb leads and <10mm in all precordial leads were collected. Associated clinical conditions were determined from clinical data, echocardiograms, and chest radiographs. Low precordial voltage was found in 256 of 150,000 ECGs (~0.2%). 50.4% of patients had discordant ECGs that correlated with classic etiologies, with a higher incidence of LV dilation in those with classic etiologies than those without. Low precordial voltage is associated with classic etiologies and LV dilation. Copyright © 2017 Elsevier Inc. All rights reserved.
III Lead ECG Pulse Measurement Sensor
NASA Astrophysics Data System (ADS)
Thangaraju, S. K.; Munisamy, K.
2015-09-01
Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.
Pavletic, A J; Pao, M; Pine, D S; Luckenbaugh, D A; Rosing, D R
2014-01-01
While there is controversy regarding utility of screening electrocardiograms (ECGs) in competitive athletes and children exposed to psychostimulants, there is no data on the use of screening ECGs in psychiatric research. We aimed to examine the prevalence and clinical significance of ECG abnormalities and their impact on eligibility for studies. We analysed 500 consecutive ECG reports from physically healthy volunteers who had a negative cardiac history, normal cardiovascular examination and no other significant medical illnesses. For the purpose of this report, all ECGs were over-read by one cardiologist. The mean age of our cohort was 28.3 ± 8.0 years. A total of 112 (22.4%) ECGs were reported as abnormal (14.2%) or borderline (8.2%). These abnormalities were considered clinically insignificant in all but eight subjects (1.6%) who underwent evaluation with an echocardiogram. All echocardiograms were normal. No subject was excluded from studies. After the over-reading, no abnormalities or isolated bradycardia were present in 37 of 112 (33%) ECGs that were initially reported as abnormal or borderline, while minor abnormalities were found in 7 of 204 (3.4%) ECGs that were reported as normal. Although screening ECGs did not detect significant cardiac pathology or affect eligibility for our studies, over 20% of subjects were labelled as having an abnormal or borderline ECG which was incorrect in one-third of cases. Strategies to minimise unintended consequences of screening are discussed. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.
Electrocardiogram interpretation and arrhythmia management: a primary and secondary care survey.
Begg, Gordon; Willan, Kathryn; Tyndall, Keith; Pepper, Chris; Tayebjee, Muzahir
2016-05-01
There is increasing desire among service commissioners to treat arrhythmia in primary care. Accurate interpretation of the electrocardiogram (ECG) is fundamental to this. ECG interpretation has previously been shown to vary widely but there is little recent data. To examine the interpretation of ECGs in primary and secondary care. A cross-sectional survey of participants' interpretation of six ECGs and hypothetical management of patients based on those ECGs, at primary care educational events, and a cardiology department in Leeds. A total of 262 primary care clinicians and 20 cardiology clinicians were surveyed via questionnaire. Answers were compared with expert electrophysiologist opinion. In primary care, abnormal ECGs were interpreted as normal by 23% of responders. ST elevation and prolonged QT were incorrectly interpreted as normal by 1% and 22%, respectively. In cardiology, abnormal ECGs were interpreted as normal by 3%. ECG provision and interpretation remains inconsistent in both primary and secondary care. Primary care practitioners are less experienced and less confident with ECG interpretation than cardiologists, and require support in this area. © British Journal of General Practice 2016.
ECG Identification System Using Neural Network with Global and Local Features
ERIC Educational Resources Information Center
Tseng, Kuo-Kun; Lee, Dachao; Chen, Charles
2016-01-01
This paper proposes a human identification system via extracted electrocardiogram (ECG) signals. Two hierarchical classification structures based on global shape feature and local statistical feature is used to extract ECG signals. Global shape feature represents the outline information of ECG signals and local statistical feature extracts the…
The asymptomatic teenager with an abnormal electrocardiogram.
Singh, Harinder R
2014-02-01
Use of medications for attention-deficit hyperkinetic disorder and preparticipation sports physical examination has led to an increase in number of electrocardiograms (ECG) performed during adolescence. Interpreting ECGs in children and young adults must take into account the evolutionary changes with age and the benign variants, which are usually not associated with heart disease. It is crucial for primary-care providers to recognize the changes on ECG associated with heart disease and risk of sudden death. In this article, the significance, sensitivity, specificity, and the diagnostic workup of these findings in the asymptomatic teenager are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.
[Synchronous playing and acquiring of heart sounds and electrocardiogram based on labVIEW].
Dan, Chunmei; He, Wei; Zhou, Jing; Que, Xiaosheng
2008-12-01
In this paper is described a comprehensive system, which can acquire heart sounds and electrocardiogram (ECG) in parallel, synchronize the display; and play of heart sound and make auscultation and check phonocardiogram to tie in. The hardware system with C8051F340 as the core acquires the heart sound and ECG synchronously, and then sends them to indicators, respectively. Heart sounds are displayed and played simultaneously by controlling the moment of writing to indicator and sound output device. In clinical testing, heart sounds can be successfully located with ECG and real-time played.
2009-06-05
were obtained: (1) blood analysis before, immediately after, and 24 hours after exposure, (2) 12-lead electrocardiogram (ECG) recordings before and...this report focuses on the blood chemistry analysis, ECG evaluation, psychomotor function assessment, and post-exposure interview findings. 15. SUBJECT... Blood Chemistry Characteristics ................ 13 Table 2: Summary of Electrocardiogram Analysis Before and After X-26 TASER® Exposure
Zhou, Yu; Ren, Jie
2011-04-01
We put forward a new concept of software oversampling mapping system for electrocardiogram (ECG) to assist the research of the ECG inverse problem to improve the generality of mapping system and the quality of mapping signals. We then developed a conceptual system based on the traditional ECG detecting circuit, Labview and DAQ card produced by National Instruments, and at the same time combined the newly-developed oversampling method into the system. The results indicated that the system could map ECG signals accurately and the quality of the signals was good. The improvement of hardware and enhancement of software made the system suitable for mapping in different situations. So the primary development of the software for oversampling mapping system was successful and further research and development can make the system a powerful tool for researching ECG inverse problem.
Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S
2007-03-01
This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.
Marcolino, Milena S; Carvalho, Bárbara C; Lucena, Aline M; França, Ana Luiza N; Pessoa, Cristiane G; Neves, Daniel S; Alkmim, Maria Beatriz M
2015-01-01
The Telehealth Network of Minas Gerais (TNMG) is a public telehealth service in Brazil that has performed electrocardiogram (ECG) analysis since 2005. From February to March 2014, 28% of ECGs were classified as "emergency" by the primary care tele-health sites. This quasi-experimental study aimed to investigate the reasons behind the high number of emergency ECGs being sent in, the implementation of corrective actions, and an assessment of the impact of these actions. In the 1st phase, primary care units that sent >70% of ECGs as emergency from February to March 2014 were selected. The 2nd phase consisted of the intervention. In the 3rd phase, the proportion of ECGs sent as an emergency during the 1st and 2nd months post intervention were assessed. Of the 63 cities selected during the 1st phase, 50% of the practitioners did not know the proper definition of emergency. After the intervention, 67% of the cities had a significant reduction in the proportion of ECGs sent as an emergency during the 1st month, and 17% had a significant reduction during the 2nd month.
Reconfigurable Embedded System for Electrocardiogram Acquisition.
Kay, Marcel Seiji; Iaione, Fábio
2015-01-01
Smartphones include features that offers the chance to develop mobile systems in medical field, resulting in an area called mobile-health. One of the most common medical examinations is the electrocardiogram (ECG), which allows the diagnosis of various heart diseases, leading to preventative measures and preventing more serious problems. The objective of this study was to develop a wireless reconfigurable embedded system using a FPAA (Field Programmable Analog Array), for the acquisition of ECG signals, and an application showing and storing these signals on Android smartphones. The application also performs the partial FPAA reconfiguration in real time (adjustable gain). Previous studies using FPAA usually use the development boards provided by the manufacturer (high cost), do not allow the reconfiguration in real time, use no smartphone and communicate via cables. The parameters tested in the acquisition circuit and the quality of ECGs registered in an individual were satisfactory.
Edla, Shwetha; Kovvali, Narayan; Papandreou-Suppappola, Antonia
2012-01-01
Constructing statistical models of electrocardiogram (ECG) signals, whose parameters can be used for automated disease classification, is of great importance in precluding manual annotation and providing prompt diagnosis of cardiac diseases. ECG signals consist of several segments with different morphologies (namely the P wave, QRS complex and the T wave) in a single heart beat, which can vary across individuals and diseases. Also, existing statistical ECG models exhibit a reliance upon obtaining a priori information from the ECG data by using preprocessing algorithms to initialize the filter parameters, or to define the user-specified model parameters. In this paper, we propose an ECG modeling technique using the sequential Markov chain Monte Carlo (SMCMC) filter that can perform simultaneous model selection, by adaptively choosing from different representations depending upon the nature of the data. Our results demonstrate the ability of the algorithm to track various types of ECG morphologies, including intermittently occurring ECG beats. In addition, we use the estimated model parameters as the feature set to classify between ECG signals with normal sinus rhythm and four different types of arrhythmia.
Teaching crucial skills: An electrocardiogram teaching module for medical students.
Chudgar, Saumil M; Engle, Deborah L; Grochowski, Colleen O'Connor; Gagliardi, Jane P
2016-01-01
Medical student performance in electrocardiogram (ECG) interpretation at our institution could be improved. Varied resources exist to teach students this essential skill. We created an ECG teaching module (ECGTM) of 75 cases representing 15 diagnoses to improve medical students' performance and confidence in ECG interpretation. Students underwent pre- and post-clerkship testing to assess ECG interpretation skills and confidence and also end-of-clinical-year testing in ECG and laboratory interpretation. Performance was compared for the years before and during ECGTM availability. Eighty-four percent of students (total n=101) reported using the ECGTM; 98% of those who used it reported it was useful. Students' performance and confidence were higher on the post-test. Students with access to the ECGTM (n=101) performed significantly better than students from the previous year (n=90) on the end-of-year ECG test. The continuous availability of an ECGTM was associated with improved confidence and ability in ECG interpretation. The ECGTM may be another available tool to help students as they learn to read ECGs. Copyright © 2016 Elsevier Inc. All rights reserved.
Electrocardiogram signal denoising based on empirical mode decomposition technique: an overview
NASA Astrophysics Data System (ADS)
Han, G.; Lin, B.; Xu, Z.
2017-03-01
Electrocardiogram (ECG) signal is nonlinear and non-stationary weak signal which reflects whether the heart is functioning normally or abnormally. ECG signal is susceptible to various kinds of noises such as high/low frequency noises, powerline interference and baseline wander. Hence, the removal of noises from ECG signal becomes a vital link in the ECG signal processing and plays a significant role in the detection and diagnosis of heart diseases. The review will describe the recent developments of ECG signal denoising based on Empirical Mode Decomposition (EMD) technique including high frequency noise removal, powerline interference separation, baseline wander correction, the combining of EMD and Other Methods, EEMD technique. EMD technique is a quite potential and prospective but not perfect method in the application of processing nonlinear and non-stationary signal like ECG signal. The EMD combined with other algorithms is a good solution to improve the performance of noise cancellation. The pros and cons of EMD technique in ECG signal denoising are discussed in detail. Finally, the future work and challenges in ECG signal denoising based on EMD technique are clarified.
QRS Detection Algorithm for Telehealth Electrocardiogram Recordings.
Khamis, Heba; Weiss, Robert; Xie, Yang; Chang, Chan-Wei; Lovell, Nigel H; Redmond, Stephen J
2016-07-01
QRS detection algorithms are needed to analyze electrocardiogram (ECG) recordings generated in telehealth environments. However, the numerous published QRS detectors focus on clean clinical data. Here, a "UNSW" QRS detection algorithm is described that is suitable for clinical ECG and also poorer quality telehealth ECG. The UNSW algorithm generates a feature signal containing information about ECG amplitude and derivative, which is filtered according to its frequency content and an adaptive threshold is applied. The algorithm was tested on clinical and telehealth ECG and the QRS detection performance is compared to the Pan-Tompkins (PT) and Gutiérrez-Rivas (GR) algorithm. For the MIT-BIH Arrhythmia database (virtually artifact free, clinical ECG), the overall sensitivity (Se) and positive predictivity (+P) of the UNSW algorithm was >99%, which was comparable to PT and GR. When applied to the MIT-BIH noise stress test database (clinical ECG with added calibrated noise) after artifact masking, all three algorithms had overall Se >99%, and the UNSW algorithm had higher +P (98%, p < 0.05) than PT and GR. For 250 telehealth ECG records (unsupervised recordings; dry metal electrodes), the UNSW algorithm had 98% Se and 95% +P which was superior to PT (+P: p < 0.001) and GR (Se and +P: p < 0.001). This is the first study to describe a QRS detection algorithm for telehealth data and evaluate it on clinical and telehealth ECG with superior results to published algorithms. The UNSW algorithm could be used to manage increasing telehealth ECG analysis workloads.
Gu, Jiwei; Andreasen, Jan J; Melgaard, Jacob; Lundbye-Christensen, Søren; Hansen, John; Schmidt, Erik B; Thorsteinsson, Kristinn; Graff, Claus
2017-02-01
To investigate if electrocardiogram (ECG) markers from routine preoperative ECGs can be used in combination with clinical data to predict new-onset postoperative atrial fibrillation (POAF) following cardiac surgery. Retrospective observational case-control study. Single-center university hospital. One hundred consecutive adult patients (50 POAF, 50 without POAF) who underwent coronary artery bypass grafting, valve surgery, or combinations. Retrospective review of medical records and registration of POAF. Clinical data and demographics were retrieved from the Western Denmark Heart Registry and patient records. Paper tracings of preoperative ECGs were collected from patient records, and ECG measurements were read by two independent readers blinded to outcome. A subset of four clinical variables (age, gender, body mass index, and type of surgery) were selected to form a multivariate clinical prediction model for POAF and five ECG variables (QRS duration, PR interval, P-wave duration, left atrial enlargement, and left ventricular hypertrophy) were used in a multivariate ECG model. Adding ECG variables to the clinical prediction model significantly improved the area under the receiver operating characteristic curve from 0.54 to 0.67 (with cross-validation). The best predictive model for POAF was a combined clinical and ECG model with the following four variables: age, PR-interval, QRS duration, and left atrial enlargement. ECG markers obtained from a routine preoperative ECG may be helpful in predicting new-onset POAF in patients undergoing cardiac surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
de Chazal, Philip; Heneghan, Conor; Sheridan, Elaine; Reilly, Richard; Nolan, Philip; O'Malley, Mark
2003-06-01
A method for the automatic processing of the electrocardiogram (ECG) for the detection of obstructive apnoea is presented. The method screens nighttime single-lead ECG recordings for the presence of major sleep apnoea and provides a minute-by-minute analysis of disordered breathing. A large independently validated database of 70 ECG recordings acquired from normal subjects and subjects with obstructive and mixed sleep apnoea, each of approximately eight hours in duration, was used throughout the study. Thirty-five of these recordings were used for training and 35 retained for independent testing. A wide variety of features based on heartbeat intervals and an ECG-derived respiratory signal were considered. Classifiers based on linear and quadratic discriminants were compared. Feature selection and regularization of classifier parameters were used to optimize classifier performance. Results show that the normal recordings could be separated from the apnoea recordings with a 100% success rate and a minute-by-minute classification accuracy of over 90% is achievable.
A PDA-based electrocardiogram/blood pressure telemonitor for telemedicine.
Bolanos, Marcos; Nazeran, Homayoun; Gonzalez, Izzac; Parra, Ricardo; Martinez, Christopher
2004-01-01
An electrocardiogram (ECG) / blood pressure (BP) telemonitor consisting of comprehensive integration of various electrical engineering concepts, devices, and methods was developed. This personal digital assistant-based (PDAbased) system focused on integration of biopotential amplifiers, photoplethysmographic measurement of blood pressure, microcontroller devices, programming methods, wireless transmission, signal filtering and analysis, interfacing, and long term memory devices (24 hours) to develop a state-of-the-art ECG/BP telemonitor. These instrumentation modules were developed and tested to realize a complete and compact system that could be deployed to assist in telemedicine applications and heart rate variability studies. The specific objective of this device was to facilitate the long term monitoring and recording of ECG and blood pressure signals. This device was able to acquire ECG/BP waveforms, transmit them wirelessly to a PDA, save them onto a compact flash memory, and display them on the LCD screen of the PDA. It was also capable of calculating the heart rate (HR) in beats per minute, and providing systolic and diastolic blood pressure values.
How Will I Be Monitored After Heart Surgery?
... monitor you are described below. What is an ECG? •An electrocardiogram, or ECG or EKG machine, records your heartbeat. • Tiny wires, ... normally. •A highly trained nurse will watch the ECG at all times. •You’ll be hooked up ...
Effect of gender on computerized electrocardiogram measurements in college athletes.
Mandic, Sandra; Fonda, Holly; Dewey, Frederick; Le, Vy-van; Stein, Ricardo; Wheeler, Matt; Ashley, Euan A; Myers, Jonathan; Froelicher, Victor F
2010-06-01
Broad criteria for classifying an electrocardiogram (ECG) as abnormal and requiring additional testing prior to participating in competitive athletics have been recommended for the preparticipation examination (PPE) of athletes. Because these criteria have not considered gender differences, we examined the effect of gender on the computerized ECG measurements obtained on Stanford student athletes. Currently available computer programs require a basis for "normal" in athletes of both genders to provide reliable interpretation. During the 2007 PPE, computerized ECGs were recorded and analyzed on 658 athletes (54% male; mean age, 19 +/- 1 years) representing 22 sports. Electrocardiogram measurements included intervals and durations in all 12 leads to calculate 12-lead voltage sums, QRS amplitude and QRS area, spatial vector length (SVL), and the sum of the R wave in V5 and S wave in V2 (RSsum). By computer analysis, male athletes had significantly greater QRS duration, PR interval, Q-wave duration, J-point amplitude, and T-wave amplitude, and shorter QTc interval compared with female athletes (all P < 0.05). All ECG indicators of left ventricular electrical activity were significantly greater in males. Although gender was consistently associated with indices of atrial and ventricular electrical activity in multivariable analysis, ECG measurements correlated poorly with body dimensions. Significant gender differences exist in ECG measurements of college athletes that are not explained by differences in body size. Our tables of "normal" computerized gender-specific measurements can facilitate the development of automated ECG interpretation for screening young athletes.
Sutha, P; Jayanthi, V E
2017-12-08
Birth defect-related demise is mainly due to congenital heart defects. In the earlier stage of pregnancy, fetus problem can be identified by finding information about the fetus to avoid stillbirths. The gold standard used to monitor the health status of the fetus is by Cardiotachography(CTG), cannot be used for long durations and continuous monitoring. There is a need for continuous and long duration monitoring of fetal ECG signals to study the progressive health status of the fetus using portable devices. The non-invasive method of electrocardiogram recording is one of the best method used to diagnose fetal cardiac problem rather than the invasive methods.The monitoring of the fECG requires development of a miniaturized hardware and a efficient signal processing algorithms to extract the fECG embedded in the mother ECG. The paper discusses a prototype hardware developed to monitor and record the raw mother ECG signal containing the fECG and a signal processing algorithm to extract the fetal Electro Cardiogram signal. We have proposed two methods of signal processing, first is based on the Least Mean Square (LMS) Adaptive Noise Cancellation technique and the other method is based on the Wavelet Transformation technique. A prototype hardware was designed and developed to acquire the raw ECG signal containing the mother and fetal ECG and the signal processing techniques were used to eliminate the noises and extract the fetal ECG and the fetal Heart Rate Variability was studied. Both the methods were evaluated with the signal acquired from a fetal ECG simulator, from the Physionet database and that acquired from the subject. Both the methods are evaluated by finding heart rate and its variability, amplitude spectrum and mean value of extracted fetal ECG. Also the accuracy, sensitivity and positive predictive value are also determined for fetal QRS detection technique. In this paper adaptive filtering technique uses Sign-sign LMS algorithm and wavelet techniques with Daubechies wavelet, employed along with de noising techniques for the extraction of fetal Electrocardiogram.Both the methods are having good sensitivity and accuracy. In adaptive method the sensitivity is 96.83, accuracy 89.87, wavelet sensitivity is 95.97 and accuracy is 88.5. Additionally, time domain parameters from the plot of heart rate variability of mother and fetus are analyzed.
United in prevention-electrocardiographic screening for chronic obstructive pulmonary disease.
Lazovic, Biljana; Mazic, Sanja; Stajic, Zoran; Djelic, Marina; Zlatkovic-Svenda, Mirjana; Putnikovic, Biljana
2013-01-01
NONE DECLARED. P-wave abnormalities on the resting electrocardiogram have been associated with cardiovascular or pulmonary disease. So far, "Gothic" P wave and verticalization of the frontal plane axis is related to lung disease, particularly obstructive lung disease. We tested if inverted P wave in AVl as a lone criteria of P wave axis >70° could be screening tool for emphysema. 1095 routine electrocardiograms (ECGs) were reviewed which yielded 478 (82,1%) ECGs with vertical P-axis in sinus rhythm. Charts were reviewed for the diagnosis of COPD and emphysema based on medical history and pulmonary function tests. Electrocardiogram is very effective screening tool not only in cardiovascular field but in chronic obstructive pulmonary disease. The verticality of the P axis is usually immediately apparent, making electrocardiogram rapid screening test for emphysema.
Usefulness of Maintaining a Normal Electrocardiogram Over Time for Predicting Cardiovascular Health.
Soliman, Elsayed Z; Zhang, Zhu-Ming; Chen, Lin Y; Tereshchenko, Larisa G; Arking, Dan; Alonso, Alvaro
2017-01-15
We hypothesized that maintaining a normal electrocardiogram (ECG) status over time is associated with low cardiovascular (CV) disease in a dose-response fashion and subsequently could be used to monitor programs aimed at promoting CV health. This analysis included 4,856 CV disease-free participants from the Atherosclerosis Risk in Communities study who had a normal ECG at baseline (1987 to 1989) and complete electrocardiographic data in subsequent 3 visits (1990 to 1992, 1993 to 1995, and 1996 to 1998). Participants were classified based on maintaining their normal ECG status during these 4 visits into "maintained," "not maintained," or "inconsistent" normal ECG status as defined by the Minnesota ECG classification. CV disease events (coronary heart disease, heart failure, and stroke) were adjudicated from Atherosclerosis Risk in Communities visit-4 through 2010. Over a median follow-up of 13.2 years, 885 CV disease events occurred. The incidence rate of CV disease events was lowest among study participants who maintained a normal ECG status, followed by those with an inconsistent pattern, and then those who did not maintain their normal ECG status (trend p value <0.001). Similarly, the greater the number of visits with a normal ECG status, the lower was the incidence rate of CV disease events (trend p value <0.001). Maintaining (vs not maintaining) a normal ECG status was associated with a lower risk of CV disease, which was lower than that observed in those with inconsistent normal ECG pattern (trend p value <0.01). In conclusion, maintaining a normal ECG status over time is associated with low risk of CV disease in a dose-response fashion, suggesting its potential use as a monitoring tool for programs promoting CV health. Copyright © 2016 Elsevier Inc. All rights reserved.
[Low-power Wireless Micro Ambulatory Electrocardiogram Node].
Cai, Zhipeng; Luo, Kan; Li, Jianqing
2016-02-01
Ambulatory electrocardiogram (ECG) monitoring can effectively reduce the risk and death rate of patients with cardiovascular diseases (CVDs). The Body Sensor Network (BSN) based ECG monitoring is a new and efficien method to protect the CVDs patients. To meet the challenges of miniaturization, low power and high signal quality of the node, we proposed a novel 50 mmX 50 mmX 10 mm, 30 g wireless ECG node, which includes the single-chip an alog front-end AD8232, ultra-low power microprocessor MSP430F1611 and Bluetooth module HM-11. The ECG signal quality is guaranteed by the on-line digital filtering. The difference threshold algorithm results in accuracy of R-wave detection and heart rate. Experiments were carried out to test the node and the results showed that the pro posed node reached the design target, and it has great potential in application of wireless ECG monitoring.
Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S; Josephson, Mark; Mason, Jay W; Okin, Peter; Surawicz, Borys; Wellens, Hein
2007-03-13
This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.
Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S; Josephson, Mark; Mason, Jay W; Okin, Peter; Surawicz, Borys; Wellens, Hein
2007-03-13
This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.
Rejection of the maternal electrocardiogram in the electrohysterogram signal.
Leman, H; Marque, C
2000-08-01
The electrohysterogram (EHG) signal is mainly corrupted by the mother's electrocardiogram (ECG), which remains present despite analog filtering during acquisition. Wavelets are a powerful denoising tool and have already proved their efficiency on the EHG. In this paper, we propose a new method that employs the redundant wavelet packet transform. We first study wavelet packet coefficient histograms and propose an algorithm to automatically detect the histogram mode number. Using a new criterion, we compute a best basis adapted to the denoising. After EHG wavelet packet coefficient thresholding in the selected basis, the inverse transform is applied. The ECG seems to be very efficiently removed.
Case report: an electrocardiogram of spontaneous pneumothorax mimicking arm lead reversal.
Wieters, J Scott; Carlin, Joseph P; Morris, Andrew
2014-05-01
There are several previously documented findings for electrocardiograms (ECGs) of spontaneous pneumothorax. These findings include axis deviation, T-wave inversion, and right bundle branch block. When an ECG has the arm leads incorrectly placed, the ECG will display right axis deviation and inversion of the P waves in lead I. There have been no previously published ECGs of spontaneous pneumothorax that have shown the same findings as reversal of the limb leads of an ECG. A possible finding of spontaneous pneumothorax is an identical finding to that of an ECG that has been flagged for limb lead reversal. A patient presented in the emergency setting with acute chest pain and shortness of breath caused by a tension pneumothorax. An ECG was administered; findings indicated reversal of the arm leads (right axis deviation and inverted P waves in lead I), but there was no actual limb lead reversal present. ECG findings resolved upon resolution of the pneumothorax. If a patient presents with chest pain and shortness of breath, and the patient's ECG is flagged for limb lead reversal despite being set up correctly, the physician should raise clinical suspicion for a possible spontaneous pneumothorax. Copyright © 2014 Elsevier Inc. All rights reserved.
Exploring the Relationship Between Eye Movements and Electrocardiogram Interpretation Accuracy
NASA Astrophysics Data System (ADS)
Davies, Alan; Brown, Gavin; Vigo, Markel; Harper, Simon; Horseman, Laura; Splendiani, Bruno; Hill, Elspeth; Jay, Caroline
2016-12-01
Interpretation of electrocardiograms (ECGs) is a complex task involving visual inspection. This paper aims to improve understanding of how practitioners perceive ECGs, and determine whether visual behaviour can indicate differences in interpretation accuracy. A group of healthcare practitioners (n = 31) who interpret ECGs as part of their clinical role were shown 11 commonly encountered ECGs on a computer screen. The participants’ eye movement data were recorded as they viewed the ECGs and attempted interpretation. The Jensen-Shannon distance was computed for the distance between two Markov chains, constructed from the transition matrices (visual shifts from and to ECG leads) of the correct and incorrect interpretation groups for each ECG. A permutation test was then used to compare this distance against 10,000 randomly shuffled groups made up of the same participants. The results demonstrated a statistically significant (α 0.05) result in 5 of the 11 stimuli demonstrating that the gaze shift between the ECG leads is different between the groups making correct and incorrect interpretations and therefore a factor in interpretation accuracy. The results shed further light on the relationship between visual behaviour and ECG interpretation accuracy, providing information that can be used to improve both human and automated interpretation approaches.
Accurate Interpretation of the 12-Lead ECG Electrode Placement: A Systematic Review
ERIC Educational Resources Information Center
Khunti, Kirti
2014-01-01
Background: Coronary heart disease (CHD) patients require monitoring through ECGs; the 12-lead electrocardiogram (ECG) is considered to be the non-invasive gold standard. Examples of incorrect treatment because of inaccurate or poor ECG monitoring techniques have been reported in the literature. The findings that only 50% of nurses and less than…
[The electrocardiogram in the paediatric age group].
Sanches, M; Coelho, A; Oliveira, E; Lopes, A
2014-09-01
A properly interpreted electrocardiogram (ECG) provides important information and is an inexpensive and easy test to perform. It continues to be the method of choice for the diagnosis of arrhythmias. Although the principles of cardiac electrophysiology are the same, there are anatomical and physiological age-dependent changes which produce specific alterations in the paediatric ECG, and which may be misinterpreted as pathological. The intention of this article is to address in a systematic way the most relevant aspects of the paediatric ECG, to propose a possible reading scheme of the ECG and to review the electrocardiograph tracings most frequently found in the paediatric age group. Copyright © 2013 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.
Adaptive noise canceling of electrocardiogram artifacts in single channel electroencephalogram.
Cho, Sung Pil; Song, Mi Hye; Park, Young Cheol; Choi, Ho Seon; Lee, Kyoung Joung
2007-01-01
A new method for estimating and eliminating electrocardiogram (ECG) artifacts from single channel scalp electroencephalogram (EEG) is proposed. The proposed method consists of emphasis of QRS complex from EEG using least squares acceleration (LSA) filter, generation of synchronized pulse with R-peak and ECG artifacts estimation and elimination using adaptive filter. The performance of the proposed method was evaluated using simulated and real EEG recordings, we found that the ECG artifacts were successfully estimated and eliminated in comparison with the conventional multi-channel techniques, which are independent component analysis (ICA) and ensemble average (EA) method. From this we can conclude that the proposed method is useful for the detecting and eliminating the ECG artifacts from single channel EEG and simple to use for ambulatory/portable EEG monitoring system.
Electrocardiogram interpretation skills among ambulance nurses.
Werner, Kristoffer; Kander, Kristofer; Axelsson, Christer
2016-06-01
To describe ambulance nurses' practical electrocardiogram (ECG) interpretation skills and to measure the correlation between these skills and factors that may impact on the level of knowledge. This study was conducted using a prospective quantitative survey with questionnaires and a knowledge test. A convenience sample collection was conducted among ambulance nurses in three different districts in western Sweden. The knowledge test consisted of nine different ECGs. The score of the ECG test were correlated against the questions in the questionnaire regarding both general ECG interpretation skill and ability to identify acute myocardial infarction using Mann-Whitney U test, Kruskal-Wallis test and Spearman's rank correlation. On average, the respondents had 54% correct answers on the test and identified 46% of the ECGs indicating acute myocardial infarction. The median total score was 9 of 16 (interquartile range 7-11) and 1 of 3 (IQR 1-2) in infarction points. No correlation between ECG interpretation skill and factors such as education and professional experience was found, except that coronary care unit experience was associated with better results on the ECG test. Ambulance nurses have deficiencies in their ECG interpretation skills. This also applies to conditions where the ambulance crew has great potential to improve the outcome of the patient's health, such as myocardial infarction and cardiac arrest. Neither education, extensive experience in ambulance service nor in nursing contributed to an improved result. The only factor of importance for higher ECG interpretation knowledge was prior experience of working in a coronary care unit. © The European Society of Cardiology 2014.
CAVIAR: a tool to improve serial analysis of the 12-lead electrocardiogram.
Berg, J; Fayn, J; Edenbrandt, L; Lundh, B; Malmström, P; Rubel, P
1995-09-01
An important part of an electrocardiogram (ECG) interpretation is the comparison between the present ECG and earlier recordings. The purpose of the present study was to evaluate a combination of two computer-based methods, synthesized vectorcardiogram (VCG) and CAVIAR, in this comparison. The methods were applied to a group of 38 normal subjects and to a group of 36 patients treated with anthracyclines. A fraction of these patients are likely to develop cardiac injury during or after the treatment, since anthracyclines are known to cause heart failure and cardiomyopathy. Two ECGs were recorded on each patient, one before and one after the treatment. On each normal subject, two ECGs were recorded with an interval of 8-9 years. A synthesized VCG was calculated from each ECG and the two synthesized VCGs from each subject were analysed with the CAVIAR method. The CAVIAR analysis is a quantitative method and normal limits for four measurements were established using the normal group. Values above these limits were more frequent in the patient group than in the normal group. The conventional ECGs were also analysed visually by an experience ECG interpreter without knowledge of the result of the CAVIAR analysis. No significant serial changes were found in 10 of the patients with high CAVIAR values. Changes in the ECGs were found in two patients with normal CAVIAR values. In summary, synthesized VCG and CAVIAR could be used to highlight small serial changes that are difficult to find in a visual analysis of ECGs.
Tele-electrocardiography in the epidemiological 'Study of Health in Pomerania' (SHIP).
Alte, Dietrich; Völzke, Henry; Robinson, Daniel M; Kleine, Volker; Grabe, Hans Jörgen; John, Ulrich; Felix, Stephan B
2006-01-01
We have evaluated a portable electrocardiogram (ECG) card in the large population-based epidemiological 'Study of Health in Pomerania' (SHIP). In all, 7008 men and women (20-79 years) were randomly selected from population registries and 4310 subjects participated. Participants used an ECG card for four weeks and recorded two ECGs daily. The participants were also encouraged to record additional ECGs in the case of symptomatic arrhythmias, chest pain or dizziness. The ECGs were sent via telephone. Acrobat (.pdf) files arrived at the study centre via email. Arrhythmias were analysed by visual ECG inspection. Seventy-one per cent of the participants sent at least 80% of the requested ECGs for four weeks. There were few problems (about 70) in the total of 38,162 ECGs transmitted. Overall, 94% of all ECGs were rated as 'good'. Physicians required about 1.5 h to read approximately 100 ECGs daily. The functionality and ergonomics of ECG cards appear to be sufficiently developed for large-scale use in epidemiological studies.
... large tunnel-shaped scanner. Electrodes for an electrocardiogram ( ECG ) will be placed on your chest. The PET ... often used when other tests, such as echocardiogram (ECG) and cardiac stress tests do not provide enough ...
Gulizia, Michele Massimo; Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Franco Gensini, Gian
2017-05-01
The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, elaboration, and presentation of the signal. Several sources of artefacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depend upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high-quality ECG signal are, therefore, of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to give scientific reference for the choice of systems able to offer high quality ECG signal acquisition, processing, and presentation suitable for clinical use.
Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Franco Gensini, Gian
2017-01-01
Abstract The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, elaboration, and presentation of the signal. Several sources of artefacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depend upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high-quality ECG signal are, therefore, of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to give scientific reference for the choice of systems able to offer high quality ECG signal acquisition, processing, and presentation suitable for clinical use. PMID:28751842
Dong, Ruimin; Yang, Xiaoyan; Xing, Bangrong; Zou, Zihao; Zheng, Zhenda; Xie, Xujing; Zhu, Jieming; Chen, Lin; Zhou, Hanjian
2015-01-01
Concept mapping is an effective method in teaching and learning, however this strategy has not been evaluated among electrocardiogram (ECG) diagnosis learning. This study explored the use of concept maps to assist ECG study, and sought to analyze whether this method could improve undergraduate students’ ECG interpretation skills. There were 126 undergraduate medical students who were randomly selected and assigned to two groups, group A (n = 63) and group B (n = 63). Group A was taught to use concept maps to learn ECG diagnosis, while group B was taught by traditional methods. After the course, all of the students were assessed by having an ECG diagnostic test. Quantitative data which comprised test score and ECG features completion index was compared by using the unpaired Student’s t-test between the two groups. Further, a feedback questionnaire on concept maps used was also completed by group A, comments were evaluated by a five-point Likert scale. The test scores of ECGs interpretation was 7.36 ± 1.23 in Group A and 6.12 ± 1.39 in Group B. A significant advantage (P = 0.018) of concept maps was observed in ECG interpretation accuracy. No difference in the average ECG features completion index was observed between Group A (66.75 ± 15.35%) and Group B (62.93 ± 13.17%). According qualitative analysis, majority of students accepted concept maps as a helpful tool. Difficult to learn at the beginning and time consuming are the two problems in using this method, nevertheless most of the students indicated to continue using it. Concept maps could be a useful pedagogical tool in enhancing undergraduate medical students’ ECG interpretation skills. Furthermore, students indicated a positive attitude to it, and perceived it as a resource for learning. PMID:26221331
2011-02-10
This practical pocket-book approach to electrocardiogram (ECG) interpretation accompanies Making sense of the eCg by the same authors. it is also designed to be used alone to test knowledge of ECG interpretation and to make clinical decisions based on presented scenarios.
ECG signal analysis through hidden Markov models.
Andreão, Rodrigo V; Dorizzi, Bernadette; Boudy, Jérôme
2006-08-01
This paper presents an original hidden Markov model (HMM) approach for online beat segmentation and classification of electrocardiograms. The HMM framework has been visited because of its ability of beat detection, segmentation and classification, highly suitable to the electrocardiogram (ECG) problem. Our approach addresses a large panel of topics some of them never studied before in other HMM related works: waveforms modeling, multichannel beat segmentation and classification, and unsupervised adaptation to the patient's ECG. The performance was evaluated on the two-channel QT database in terms of waveform segmentation precision, beat detection and classification. Our waveform segmentation results compare favorably to other systems in the literature. We also obtained high beat detection performance with sensitivity of 99.79% and a positive predictivity of 99.96%, using a test set of 59 recordings. Moreover, premature ventricular contraction beats were detected using an original classification strategy. The results obtained validate our approach for real world application.
Electrocardiogram signal denoising based on a new improved wavelet thresholding
NASA Astrophysics Data System (ADS)
Han, Guoqiang; Xu, Zhijun
2016-08-01
Good quality electrocardiogram (ECG) is utilized by physicians for the interpretation and identification of physiological and pathological phenomena. In general, ECG signals may mix various noises such as baseline wander, power line interference, and electromagnetic interference in gathering and recording process. As ECG signals are non-stationary physiological signals, wavelet transform is investigated to be an effective tool to discard noises from corrupted signals. A new compromising threshold function called sigmoid function-based thresholding scheme is adopted in processing ECG signals. Compared with other methods such as hard/soft thresholding or other existing thresholding functions, the new algorithm has many advantages in the noise reduction of ECG signals. It perfectly overcomes the discontinuity at ±T of hard thresholding and reduces the fixed deviation of soft thresholding. The improved wavelet thresholding denoising can be proved to be more efficient than existing algorithms in ECG signal denoising. The signal to noise ratio, mean square error, and percent root mean square difference are calculated to verify the denoising performance as quantitative tools. The experimental results reveal that the waves including P, Q, R, and S waves of ECG signals after denoising coincide with the original ECG signals by employing the new proposed method.
Development of electrocardiogram intervals during growth of FVB/N neonate mice
2010-01-01
Background Electrocardiography remains the best diagnostic tool and therapeutic biomarker for a spectrum of pediatric diseases involving cardiac or autonomic nervous system defects. As genetic links to these disorders are established and transgenic mouse models produced in efforts to understand and treat them, there is a surprising lack of information on electrocardiograms (ECGs) and ECG abnormalities in neonate mice. This is likely due to the trauma and anaesthesia required of many legacy approaches to ECG recording in mice, exacerbated by the fragility of many mutant neonates. Here, we use a non-invasive system to characterize development of the heart rate and electrocardiogram throughout the growth of conscious neonate FVB/N mice. Results We examine ECG waveforms as early as two days after birth. At this point males and females demonstrate comparable heart rates that are 50% lower than adult mice. Neonatal mice exhibit very low heart rate variability. Within 12 days of birth PR, QRS and QTc interval durations are near adult values while heart rate continues to increase until weaning. Upon weaning FVB/N females quickly develop slower heart rates than males, though PR intervals are comparable between sexes until a later age. This suggests separate developmental events may contribute to these gender differences in electrocardiography. Conclusions We provide insight with a new level of detail to the natural course of heart rate establishment in neonate mice. ECG can now be conveniently and repeatedly used in neonatal mice. This should serve to be of broad utility, facilitating further investigations into development of a diverse group of diseases and therapeutics in preclinical mouse studies. PMID:20735846
Pimentel, Alan Santos; Alves, Eduardo da Silva; Alvim, Rafael de Oliveira; Nunes, Rogério Tasca; Costa, Carlos Magno Amaral; Lovisi, Júlio Cesar Moraes; Perrout de Lima, Jorge Roberto
2010-05-01
The 4-second exercise test (T4s) evaluates the cardiac vagal tone during the initial heart rate (HR) transient at sudden dynamic exercise, through the identification of the cardiac vagal index (CVI) obtained from the electrocardiogram (ECG). To evaluate the use of the Polar S810 heart rate monitor (HRM) as an alternative resource to the use of the electrocardiogram in the 4-second exercise test. In this study, 49 male individuals (25 +/- 20 years, 176 +/-12 cm, 74 +/- 6 kg) underwent the 4-second exercise test. The RR intervals were recorded simultaneously by ECG and HRM. We calculated the mean and the standard deviation of the last RR interval of the pre-exercise period, or of the first RR interval of the exercise period, whichever was longer (RRB), of the shortest RR interval of the exercise period (RRC), and of the CVI obtained by ECG and HRM. We used the Student t-test for dependent samples (p < or 0.05) to test the significance of the differences between means. To identify the correlation between the ECG and the HRM, we used the linear regression to calculate the Pearson's correlation coefficient and the strategy proposed by Bland and Altman. Linear regression showed r(2) of 0.9999 for RRB, 0.9997 for RRC, and 0.9996 for CVI. Bland e Altman strategy presented standard deviation of 0.92 ms for RRB, 0.86 ms for RRC, and 0.002 for CVI. Polar S810 HRM was more efficient in the application of T4s compared to the ECG.
Electrocardiography (ECG) is one of the standard technologies used to monitor and assess cardiac function, and provide insight into the mechanisms driving myocardial pathology. Increased understanding of the effects of cardiovascular disease on rat ECG may help make ECG assessmen...
Fuchs, Tomasz; Pomorski, Michał; Grobelak, Krzysztof; Tomiałowicz, Marek; Zimmer, Mariusz
2014-01-01
Fetal electrocardiography is one of the methods for monitoring the well-being of the fetus. Signal loss limits the proper interpretation of electrocardiogram traces. The aim of this study was to assess the average signal loss in non-invasive abdominal fetal electrocardiogram (fECG) monitoring using the KOMPOREL fetal monitoring system (ITAM, Zabrze, Poland) in women between 28 and 42 week of pregnancy. The results were compared to FIGO (International Federation of Gynaecology and Obstetric) and DGGG (Deutsche Gesellschaft für Gynäkologie und Geburtshilfe e.V.) recommendations concerning fetal heart monitoring. The correlation between fetal ECG signal quality, week of pregnancy and patient BMI was evaluated. 773 pregnant women, hospitalized and diagnosed in the Department of Gynecology and Obstetrics, Wroclaw Medical University, underwent 30 min of abdominal fECG recordings using the KOMPOREL fetal monitoring system. The average signal loss in abdominal fECG monitoring in the study group was 32%. FIGO recommendations describe an acceptable fetal signal loss of 20%. In our study, 46% (357/773) of the recordings were up to FIGO standards, with fetal heart rate success rates above 80%. According to DGGG guidelines, with acceptable fetal signal loss of 15%, only 39% (303/773) of the recordings could be assessed as accurate. No correlation between fECG signal quality, week of pregnancy and patient BMI was proved. The average signal loss in abdominal fECG monitoring in our study group was 32%. Low fECG signal quality may constitute a potentially limiting factor of the described fetal heart monitoring system. No relationship between fECG signal quality, week of pregnancy and patient BMI was proved.
Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang
2016-06-01
The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.
A systematic review of prenatal screening for congenital heart disease by fetal electrocardiography.
Verdurmen, Kim M J; Eijsvoogel, Noortje B; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; van Laar, Judith O E H; Oei, S Guid
2016-11-01
Congenital heart disease (CHD) is the most common severe congenital anomaly worldwide. Diagnosis early in pregnancy is important, but the detection rate by two-dimensional ultrasonography is only 65%-81%. To evaluate existing data on CHD and noninvasive abdominal fetal electrocardiography (ECG). A systematic review was performed through a search of the Cochrane Library, PubMed, and Embase for studies published up to April 2016 using the terms "congenital heart disease," "fetal electrocardiogram," and other similar keywords. Primary articles that described changes in fetal ECG among fetuses with CHD published in English were included. Outcomes of interest were changes in fetal ECG parameters observed for fetuses with congenital heart disease. Findings were reported descriptively. Only five studies described changes observed in the fetal electrocardiogram for fetuses with CHD, including heart rate, heart rate variability, and PR, QRS, and QT intervals. Fetal ECG reflects the intimate relationship between the cardiac nerve conduction system and the structural morphology of the heart. It seems particularly helpful in detecting the electrophysiological effects of cardiac anatomic defects (e.g. hypotrophy, hypertrophy, and conduction interruption). Fetal ECG might be a promising clinical tool to complement ultrasonography in the screening program for CHD. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
ECG Electrocardiogram (For Parents)
... presented in a standard sequence. Now the ECG tracings are stored as computer files that can be ... of Use Notice of Nondiscrimination Visit the Nemours Web site. Note: All information on KidsHealth® is for ...
Android based self-diagnostic electrocardiogram system for mobile healthcare.
Choo, Kan-Yeep; Ling, Huo-Chong; Lo, Yew-Chiong; Yap, Zuo-Han; Pua, Jun-Sheng; Phan, Raphael C-W; Goh, Vik-Tor
2015-01-01
Cardiovascular diseases are the most common cause of death worldwide and are characterized by arrhythmia (i.e. irregular rhythm of heartbeat). Arrhythmia occasionally happens under certain conditions, such as stress. Therefore, it is difficult to be diagnosed using electrocardiogram (ECG) devices available in hospitals for just a few minutes. Constant diagnosis and monitoring of heartbeat is required to reduce death caused by cardiovascular diseases. Mobile healthcare system has emerged as a potential solution to assist patients in monitoring their own heart condition, especially those who are isolated from the reference hospital. This paper proposes a self-diagnostic electrocardiogram system for mobile healthcare that has the capability to perform a real-time ECG diagnostic. The self-diagnostic capability of a real-time ECG signal is achieved by implementing a detrended fluctuation analysis (DFA) method. The result obtained from DFA is used to display the patient's health condition on a smartphone anytime and anywhere. If the health condition is critical, the system will alert the patient and his medical practitioner for further diagnosis. Experimental results verified the validity of the developed ECG diagnostic application on a smartphone. The proposed system can potentially reduce death caused by cardiovascular diseases by alerting the patient possibly undergoing a heart attack.
Electrocardiogram artifact caused by rigors mimicking narrow complex tachycardia: a case report.
Matthias, Anne Thushara; Indrakumar, Jegarajah
2014-02-04
The electrocardiogram (ECG) is useful in the diagnosis of cardiac and non-cardiac conditions. Rigors due to shivering can cause electrocardiogram artifacts mimicking various cardiac rhythm abnormalities. We describe an 80-year-old Sri Lankan man with an abnormal electrocardiogram mimicking narrow complex tachycardia during the immediate post-operative period. Electrocardiogram changes caused by muscle tremor during rigors could mimic a narrow complex tachycardia. Identification of muscle tremor as a cause of electrocardiogram artifact can avoid unnecessary pharmacological and non-pharmacological intervention to prevent arrhythmias.
Zhao, Wenjiao; Lu, Guihua; Liu, Li; Sun, Zhishan; Wu, Mingxin; Yi, Wenyan; Chen, Haiyan; Li, Yanhui
2018-01-01
Background The aim of this study was to compare the use of the standard 12-lead electrocardiogram (ECG) with the SAN-Atrial-AVN-His (SAAH) ECG (Model PHS-A10), a new automated and integrated signals recognition system that detects micro-waveforms within the P, QRS, and T-wave, in a pig model of acute myocardial infarction (MI). Material/Methods Six medium-sized domestic Chinese pigs underwent general anesthesia, and an angioplasty balloon was placed and dilated for 120 minutes in the first diagonal coronary artery arising from the left anterior descending (LAD) coronary artery. A standard ECG and a SAAH ECG (Model PHS-A10) were used to evaluate: 1) the number of wavelets in ST-T segment in lead V5; 2) the duration of the repolarization initial (Ri), or duration of the wavelets starting from the J-point to the endpoint of the wavelets in the ST interval; 3) the duration of the repolarization terminal (Rt), of the wavelets, starting from the endpoint of the wavelets in the ST interval to the cross-point of the T-wave and baseline; 4) the ratio Ri: Rt. Results Following coronary artery occlusion, duration of Ri and Ri/Rt increased, and Rt decreased, which was detected by the SAAH ECG (Model PHS-A10) within 12 seconds, compared with standard ECG that detected ST segment depression at 24 seconds following coronary artery occlusion. Conclusions The findings from this preliminary study in a pig model of acute MI support the need for clinical studies to evaluate the SAAH ECG (Model PHS-A10) for the early detection of acute MI. PMID:29502127
Zhao, Wenjiao; Lu, Guihua; Liu, Li; Sun, Zhishan; Wu, Mingxin; Yi, Wenyan; Chen, Haiyan; Li, Yanhui; Tang, Lilong; Zeng, Jianping
2018-03-04
BACKGROUND The aim of this study was to compare the use of the standard 12-lead electrocardiogram (ECG) with the SAN-Atrial-AVN-His (SAAH) ECG (Model PHS-A10), a new automated and integrated signals recognition system that detects micro-waveforms within the P, QRS, and T-wave, in a pig model of acute myocardial infarction (MI). MATERIAL AND METHODS Six medium-sized domestic Chinese pigs underwent general anesthesia, and an angioplasty balloon was placed and dilated for 120 minutes in the first diagonal coronary artery arising from the left anterior descending (LAD) coronary artery. A standard ECG and a SAAH ECG (Model PHS-A10) were used to evaluate: 1) the number of wavelets in ST-T segment in lead V5; 2) the duration of the repolarization initial (Ri), or duration of the wavelets starting from the J-point to the endpoint of the wavelets in the ST interval; 3) the duration of the repolarization terminal (Rt), of the wavelets, starting from the endpoint of the wavelets in the ST interval to the cross-point of the T-wave and baseline; 4) the ratio Ri: Rt. RESULTS Following coronary artery occlusion, duration of Ri and Ri/Rt increased, and Rt decreased, which was detected by the SAAH ECG (Model PHS-A10) within 12 seconds, compared with standard ECG that detected ST segment depression at 24 seconds following coronary artery occlusion. CONCLUSIONS The findings from this preliminary study in a pig model of acute MI support the need for clinical studies to evaluate the SAAH ECG (Model PHS-A10) for the early detection of acute MI.
United in Prevention–Electrocardiographic Screening for Chronic Obstructive Pulmonary Disease
Mazic, Sanja; Stajic, Zoran; Djelic, Marina; Zlatkovic-Svenda, Mirjana; Putnikovic, Biljana
2013-01-01
CONFLICT OF INTEREST: NONE DECLARED Introduction P-wave abnormalities on the resting electrocardiogram have been associated with cardiovascular or pulmonary disease. So far, “Gothic” P wave and verticalization of the frontal plane axis is related to lung disease, particularly obstructive lung disease. Aim We tested if inverted P wave in AVl as a lone criteria of P wave axis >70° could be screening tool for emphysema. Material and method 1095 routine electrocardiograms (ECGs) were reviewed which yielded 478 (82,1%) ECGs with vertical P-axis in sinus rhythm. Charts were reviewed for the diagnosis of COPD and emphysema based on medical history and pulmonary function tests. Conclusion Electrocardiogram is very effective screening tool not only in cardiovascular field but in chronic obstructive pulmonary disease. The verticality of the P axis is usually immediately apparent, making electrocardiogram rapid screening test for emphysema. PMID:24058253
Bluetooth telemetry system for a wearable electrocardiogram
NASA Astrophysics Data System (ADS)
Green, Ryan B.
The rise of wireless networks has led to a new market in medicine: remote patient monitoring. Practitioners now desire to monitor the health conditions of their patients after hospital release. With the large number of cardiac related deaths and this new demand in medicine being the motivation, this study developed a BluetoothRTM telemetry system for a wearable Electrocardiogram. This study also developed a compression t-shirt to hold the ECG and telemetry system. This device communicates the ECG signal of a patient to an Android device within the ISM frequency bands (2.4-2.48 GHz) where the data is displayed and stored in real time. This study is a stepping stone toward more portable heart monitoring that can communicate with the doctor in real time from remote locations.
Park, Sung Min; Lee, Jin Hong; Choi, Seong Wook
2014-12-01
The ventricular electrocardiogram (v-ECG) was developed for long-term monitoring of heartbeats in patients with a left ventricular assist device (LVAD) and does not normally have the functionality necessary to detect additional heart irregularities that can progress to critical arrhythmias. Although the v-ECG has the benefits of physiological optimization and counterpulsation control, when abnormal heartbeats occur, the v-ECG does not show the distinct abnormal waveform that enables easy detection of an abnormal heartbeat among normal heartbeats on the conventional ECG. In this study, the v-ECGs of normal and abnormal heartbeats are compared with each other with respect to peak-to-peak voltage, area, and maximal slopes, and a new method to detect abnormal heartbeats is suggested. In a series of animal experiments with three porcine models (Yorkshire pigs weighing 30-40 kg), a v-ECG and conventional ECG were taken simultaneously during LVAD perfusion. Clinical experts found 104 abnormal heartbeats from the saved conventional ECG data and confirmed that the other 3159 heartbeats were normal. Almost all of the abnormal heartbeats were premature ventricular contractions (PVCs), and there was short-term tachycardia for 3 s. A personal computer was used to automatically detect abnormal heartbeats with the v-ECG according to the new method, and its results were compared with the clinicians' results. The new method found abnormal heartbeats with 90% accuracy, and less than 15% of the total PVCs were missed. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Clinical Application of Electrocardiography.
ERIC Educational Resources Information Center
Brammell, H. L.; Orr, William
The scalar electrocardiogram (ECG) is one of the most important and commonly used clinical tools in medicine. A detailed description of the recordings of cardiac electrical activity made by the ECG is presented, and the vast numbers of uses made with the data provided by this diagnostic tool are cited. Clinical applications of the ECG are listed.…
Detection of Electrocardiogram by Electrodes with Fabrics Using Capacitive Coupling
NASA Astrophysics Data System (ADS)
Ueno, Akinori; Furusawa, Yoichi; Hoshino, Hiroshi; Ishiyama, Yoji
This article reports on a novel technique for detecting electrocardiogram (ECG) at a condition where thin cloth is interpolated between sensing electrodes and the skin to which the electrodes are attached. The technique is based upon capacitive coupling composed of the electrode, the cloth and the skin, so that the electrode can lead alternating electrocardiographic current through capacitance of the coupling. The technique is also founded on impedance transforming circuit that has extremely high input impedance around 1000GΩ and low output impedance, so as to match high output impedance of the electrode to low input impedance required by subsequent circuitry. A pilot ECG measuring device was manufactured using the technique and experiments showed (1) ECG recordings using the device with silk of 240μm thickness or with cotton of 564μm thickness were quite similar to ECGs recorded from the skin using conventional system, (2) stable ECGs were observed with the silk below 600μm thickness or with the cotton below 1128μm thickness, (3) effects of long-term measurement and perspiration on ECG waveform were negligible. These results prove feasibility of the proposed technique for detecting ECG by electrodes with fabrics.
Brunetti, Natale Daniele; Dellegrottaglie, Giulia; Lopriore, Claudio; Di Giuseppe, Giuseppe; De Gennaro, Luisa; Lanzone, Saverio; Di Biase, Matteo
2014-03-01
Telemedicine has been shown to improve quality of health-care delivery in several fields of medicine; its cost-effectiveness, however, is still a matter of debate. Pre-hospital telemedicine electrocardiogram triage for regional public emergency medical service may reduce costs. An economic evaluation (cost analysis) was performed from the perspective of regional health-care system. Patients enrolled in the study and considered for cost analysis were those who called the local emergency medical service (EMS; dialing 1-1-8) during 2012 and underwent prehospital field triage with a telemedicine electrocardiogram (ECG) in the case of suspected acute cardiac disease (acute coronary syndrome, arrhythmia). The prehospital ECGs were read by a remote cardiologist, available 24/7. Cost savings associated with this method were calculated by subtracting the cost of prehospital triage with telemedicine support from the cost of conventional emergency department triage (ECG and consultation by a cardiologist). During 2012, the regional EMS performed 109 750 ECGs by telemedicine support. The associated total cost for the regional health-care system was €1 833 333, with a €16.70 cost per single ECG/consultation. Given the cost of similar conventional emergency department treatment from a regional rate list of €24.80 to €55.20, the savings was €8.10 to €38.40 per ECG/consultation (total savings, €891 759.50 to €4 219 379.50). The cost for ruling out an acute cardiac disease was €25.30; for a prehospital diagnosis of cardiovascular disease, €49.20. With 629 prehospital diagnoses of ST-elevation myocardial infarction and reported reductions in mortality thanks to prehospital diagnosis deduced from prior studies, 69 lives per year presumably could be saved, with a cost per quality-adjusted life year gained of €1927, €990/€ - 2508 after correction for potential savings. Prehospital EMS triage with telemedicine ECG in patients with suspected acute cardiac disease may reduce health-care costs. © 2014 Wiley Periodicals, Inc.
New ideas for teaching electrocardiogram interpretation and improving classroom teaching content.
Zeng, Rui; Yue, Rong-Zheng; Tan, Chun-Yu; Wang, Qin; Kuang, Pu; Tian, Pan-Wen; Zuo, Chuan
2015-01-01
Interpreting an electrocardiogram (ECG) is not only one of the most important parts of diagnostics but also one of the most difficult areas to teach. Owing to the abstract nature of the basic theoretical knowledge of the ECG, its scattered characteristics, and tedious and difficult-to-remember subject matter, teaching how to interpret ECGs is as difficult for teachers to teach as it is for students to learn. In order to enable medical students to master basic knowledge of ECG interpretation skills in a limited teaching time, we modified the content used for traditional ECG teaching and now propose a new ECG teaching method called the "graphics-sequence memory method." A prospective randomized controlled study was designed to measure the actual effectiveness of ECG learning by students. Two hundred students were randomly placed under a traditional teaching group and an innovative teaching group, with 100 participants in each group. The teachers in the traditional teaching group utilized the traditional teaching outline, whereas the teachers in the innovative teaching group received training in line with the proposed teaching method and syllabus. All the students took an examination in the final semester by analyzing 20 ECGs from real clinical cases and submitted their ECG reports. The average ECG reading time was 32 minutes for the traditional teaching group and 18 minutes for the innovative teaching group. The average ECG accuracy results were 43% for the traditional teaching group and 77% for the innovative teaching group. Learning to accurately interpret ECGs is an important skill in the cardiac discipline, but the ECG's mechanisms are intricate and the content is scattered. Textbooks tend to make the students feel confused owing to the restrictions of the length and the format of the syllabi, apart from many other limitations. The graphics-sequence memory method was found to be a useful method for ECG teaching.
Knol, Remco J J; Kan, Huub; Wondergem, Maurits; Cornel, Jan H; Umans, Victor A W M; van der Ploeg, Tjeerd; van der Zant, Friso M
2018-04-01
The value of exercise electrocardiogram (ExECG) in symptomatic female patients with low to intermediate risk for significant coronary artery disease (CAD) has been under debate for many years, and nondiagnostic or even erroneous test results are frequently encountered. Cardiac-CT may be more appropriate to exclude CAD in women. This study compares the results of ExECGs with those of cardiac-CTs, performed within a time frame of 1 month in an all-comers female chest pain population. Five hundred fifty-one consecutive female patients from a patient registry were included. ExECGs were negative in 324 (59%), positive in 14 (3%), and nondiagnostic in 213 (39%) patients. CAD was revealed by cardiac-CT in 57% of the women with negative ExECG. No signs of CAD were present on cardiac-CT in 64% of the women with a positive ExECG. Cardiac-CT showed presence of CAD in 268/551 (49%) patients, of whom 56/268 (21%) was diagnosed with ≥50% stenosis. The ExECG of the latter group was negative in 26 (46%), inconclusive in 29 (52%), and positive in 1 (2%). Considering ≥50% stenosis at cardiac-CT as the reference, sensitivity, specificity, PPV, and NPV of ExECG for the present population were 3.7%, 95.7%, 7.1%, and 91.7%, respectively. Similar diagnostic performance was calculated when considering ≥70% stenosis at cardiac-CT as the reference. ExECG failed to detect CAD in more than half of this cohort and in almost half of women with >50% stenosis at cardiac-CT. Importantly, no CAD was detected by cardiac-CT in 64% of women with a positive ExECG. ExECG is therefore questionable as a diagnostic strategy in women with low-to-intermediate risk of CAD, although prospective studies are warranted to determine whether replacing ExECG by cardiac-CT provides better prognoses.
State of the art techniques for preservation and reuse of hard copy electrocardiograms.
Lobodzinski, Suave M; Teppner, Ulrich; Laks, Michael
2003-01-01
Baseline examinations and periodic reexaminations in longitudinal population studies, together with ongoing surveillance for morbidity and mortality, provide unique opportunities for seeking ways to enhance the value of electrocardiography (ECG) as an inexpensive and noninvasive tool for prognosis and diagnosis. We used newly developed optical ECG waveform recognition (OEWR) technique capable of extracting raw waveform data from legacy hard copy ECG recording. Hardcopy ECG recordings were scanned and processed by the OEWR algorithm. The extracted ECG datasets were formatted into a newly proposed, vendor-neutral, ECG XML data format. Oracle database was used as a repository for ECG records in XML format. The proposed technique for XML encapsulation of OEWR processed hard copy records resulted in an efficient method for inclusion of paper ECG records into research databases, thus providing their preservation, reuse and accession.
Matched Filtering for Heart Rate Estimation on Compressive Sensing ECG Measurements.
Da Poian, Giulia; Rozell, Christopher J; Bernardini, Riccardo; Rinaldo, Roberto; Clifford, Gari D
2017-09-14
Compressive Sensing (CS) has recently been applied as a low complexity compression framework for long-term monitoring of electrocardiogram signals using Wireless Body Sensor Networks. Long-term recording of ECG signals can be useful for diagnostic purposes and to monitor the evolution of several widespread diseases. In particular, beat to beat intervals provide important clinical information, and these can be derived from the ECG signal by computing the distance between QRS complexes (R-peaks). Numerous methods for R-peak detection are available for uncompressed ECG. However, in case of compressed sensed data, signal reconstruction can be performed with relatively complex optimisation algorithms, which may require significant energy consumption. This article addresses the problem of hearth rate estimation from compressive sensing electrocardiogram (ECG) recordings, avoiding the reconstruction of the entire signal. We consider a framework where the ECG signals are represented under the form of CS linear measurements. The QRS locations are estimated in the compressed domain by computing the correlation of the compressed ECG and a known QRS template. Experiments on actual ECG signals show that our novel solution is competitive with methods applied to the reconstructed signals. Avoiding the reconstruction procedure, the proposed method proves to be very convenient for real-time, low-power applications.
Hayashi, Risa; Nakai, Kenji; Fukushima, Akimune; Itoh, Manabu; Sugiyama, Toru
2009-03-01
Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.
Thomas, Robert Joseph; Mietus, Joseph E.; Peng, Chung-Kang; Gilmartin, Geoffrey; Daly, Robert W.; Goldberger, Ary L.; Gottlieb, Daniel J.
2007-01-01
Study Objectives: Complex sleep apnea is defined as sleep disordered breathing secondary to simultaneous upper airway obstruction and respiratory control dysfunction. The objective of this study was to assess the utility of an electrocardiogram (ECG)-based cardiopulmonary coupling technique to distinguish obstructive from central or complex sleep apnea. Design: Analysis of archived polysomnographic datasets. Setting: A laboratory for computational signal analysis. Interventions: None. Measurements and Results: The PhysioNet Sleep Apnea Database, consisting of 70 polysomnograms including single-lead ECG signals of approximately 8 hours duration, was used to train an ECG-based measure of autonomic and respiratory interactions (cardiopulmonary coupling) to detect periods of apnea and hypopnea, based on the presence of elevated low-frequency coupling (e-LFC). In the PhysioNet BIDMC Congestive Heart Failure Database (ECGs of 15 subjects), a pattern of “narrow spectral band” e-LFC was especially common. The algorithm was then applied to the Sleep Heart Health Study–I dataset, to select the 15 records with the highest amounts of broad and narrow spectral band e-LFC. The latter spectral characteristic seemed to detect not only periods of central apnea, but also obstructive hypopneas with a periodic breathing pattern. Applying the algorithm to 77 sleep laboratory split-night studies showed that the presence of narrow band e-LFC predicted an increased sensitivity to induction of central apneas by positive airway pressure. Conclusions: ECG-based spectral analysis allows automated, operator-independent characterization of probable interactions between respiratory dyscontrol and upper airway anatomical obstruction. The clinical utility of spectrographic phenotyping, especially in predicting failure of positive airway pressure therapy, remains to be more thoroughly tested. Citation: Thomas RJ; Mietus JE; Peng CK; Gilmartin G; Daly RW; Goldberger AL; Gottlieb DJ. Differentiating obstructive from central and complex sleep apnea using an automated electrocardiogram-based method. SLEEP 2007;30(12):1756-1769. PMID:18246985
Govindan, R B; Kota, Srinivas; Al-Shargabi, Tareq; Massaro, An N; Chang, Taeun; du Plessis, Adre
2016-09-01
Electroencephalogram (EEG) signals are often contaminated by the electrocardiogram (ECG) interference, which affects quantitative characterization of EEG. We propose null-coherence, a frequency-based approach, to attenuate the ECG interference in EEG using simultaneously recorded ECG as a reference signal. After validating the proposed approach using numerically simulated data, we apply this approach to EEG recorded from six newborns receiving therapeutic hypothermia for neonatal encephalopathy. We compare our approach with an independent component analysis (ICA), a previously proposed approach to attenuate ECG artifacts in the EEG signal. The power spectrum and the cortico-cortical connectivity of the ECG attenuated EEG was compared against the power spectrum and the cortico-cortical connectivity of the raw EEG. The null-coherence approach attenuated the ECG contamination without leaving any residual of the ECG in the EEG. We show that the null-coherence approach performs better than ICA in attenuating the ECG contamination without enhancing cortico-cortical connectivity. Our analysis suggests that using ICA to remove ECG contamination from the EEG suffers from redistribution problems, whereas the null-coherence approach does not. We show that both the null-coherence and ICA approaches attenuate the ECG contamination. However, the EEG obtained after ICA cleaning displayed higher cortico-cortical connectivity compared with that obtained using the null-coherence approach. This suggests that null-coherence is superior to ICA in attenuating the ECG interference in EEG for cortico-cortical connectivity analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Rinard, G. A.; Steffen, D. A.; Sturm, R. E.
1979-01-01
Circuit with high common-mode rejection has ability to filter and amplify accepted analog electrocardiogram (ECG) signals of varying amplitude, shape, and polarity. In addition, low power circuit develops standardized pulses that can be counted and averaged by heart/breath rate processor.
Performance study of the wearable one-lead wireless electrocardiographic monitoring system.
Hong, Sungyoup; Yang, Yougmo; Kim, Seunghwan; Shin, Seungcheol; Lee, Inbum; Jang, Yongwon; Kim, Kiseong; Yi, Hwayeon
2009-03-01
This study attempts to compare and assess the performance of a wearable electrocardiogram (ECG) using a sensing fabric electrode and a Bluetooth network with a conventional ECG. A one-lead ECG examination was performed using Bioshirt and an iWorx 214 while walking or running at 3, 6, and 9 km per hour. A correlation coefficient of a heart rate variability (HRV) between these two devices was higher than 0.96 and power spectral density of HRV measured also showed an excellent agreement. Thus, both of these two ECG devices showed similar detection capability for R peaks. The measured values for wave duration and intervals of both devices concur with each other. The intensity of noise is controversial. The ECG device using a sensing fabric electrode and a wireless network showed an ECG signal detection and transmission capability similar to that of a conventional ECG device.
Schreck, David M; Fishberg, Robert D
2014-01-01
Objective A new cardiac “electrical” biomarker (CEB) for detection of 12-lead electrocardiogram (ECG) changes indicative of acute myocardial ischemic injury has been identified. Objective was to test CEB diagnostic accuracy. Methods This is a blinded, observational retrospective case-control, noninferiority study. A total of 508 ECGs obtained from archived digital databases were interpreted by cardiologist and emergency physician (EP) blinded reference standards for presence of acute myocardial ischemic injury. CEB was constructed from three ECG cardiac monitoring leads using nonlinear modeling. Comparative active controls included ST voltage changes (J-point, ST area under curve) and a computerized ECG interpretive algorithm (ECGI). Training set of 141 ECGs identified CEB cutoffs by receiver-operating-characteristic (ROC) analysis. Test set of 367 ECGs was analyzed for validation. Poor-quality ECGs were excluded. Sensitivity, specificity, and negative and positive predictive values were calculated with 95% confidence intervals. Adjudication was performed by consensus. Results CEB demonstrated noninferiority to all active controls by hypothesis testing. CEB adjudication demonstrated 85.3–94.4% sensitivity, 92.5–93.0% specificity, 93.8–98.6% negative predictive value, and 74.6–83.5% positive predictive value. CEB was superior against all active controls in EP analysis, and against ST area under curve and ECGI by cardiologist. Conclusion CEB detects acute myocardial ischemic injury with high diagnostic accuracy. CEB is instantly constructed from three ECG leads on the cardiac monitor and displayed instantly allowing immediate cost-effective identification of patients with acute ischemic injury during cardiac rhythm monitoring. PMID:24118724
Patocka, Catherine; Turner, Joel; Wiseman, Jeffrey
2015-11-01
There is no evidence-based description of electrocardiogram (ECG) interpretation competencies for emergency medicine (EM) trainees. The first step in defining these competencies is to develop a prioritized list of adult ECG findings relevant to EM contexts. The purpose of this study was to categorize the importance of various adult ECG diagnoses and/or findings for the EM trainee. We developed a list of potentially important adult ECG diagnoses/findings and conducted a Delphi opinion-soliciting process. Participants used a 4-point Likert scale to rate the importance of each diagnosis for EM trainees. Consensus was defined as a minimum of 75% agreement at the second round or later. In the absence of consensus, stability was defined as a shift of 20% or less after successive rounds. A purposive sampling of 22 emergency physicians participated in the Delphi process, and 16 (72%) completed the process. Of those, 15 were from 11 different EM training programs across Canada and one was an expert in EM electrocardiography. Overall, 78 diagnoses reached consensus, 42 achieved stability and one diagnosis achieved neither consensus nor stability. Out of 121 potentially important adult ECG diagnoses, 53 (44%) were considered "must know" diagnoses, 61 (50%) "should know" diagnoses, and 7 (6%) "nice to know" diagnoses. We have categorized adult ECG diagnoses within an EM training context, knowledge of which may allow clinical EM teachers to establish educational priorities. This categorization will also facilitate the development of an educational framework to establish EM trainee competency in ECG interpretation.
Nayan, Nazrul Anuar; Risman, Nur Sabrina; Jaafar, Rosmina
2016-07-27
Among vital signs of acutely ill hospital patients, respiratory rate (RR) is a highly accurate predictor of health deterioration. This study proposes a system that consists of a passive and non-invasive single-lead electrocardiogram (ECG) acquisition module and an ECG-derived respiratory (EDR) algorithm in the working prototype of a mobile application. Before estimating RR that produces the EDR rate, ECG signals were evaluated based on the signal quality index (SQI). The SQI algorithm was validated quantitatively using the PhysioNet/Computing in Cardiology Challenge 2011 training data set. The RR extraction algorithm was validated by adopting 40 MIT PhysioNet Multiparameter Intelligent Monitoring in Intensive Care II data set. The estimated RR showed a mean absolute error (MAE) of 1.4 compared with the ``gold standard'' RR. The proposed system was used to record 20 ECGs of healthy subjects and obtained the estimated RR with MAE of 0.7 bpm. Results indicate that the proposed hardware and algorithm could replace the manual counting method, uncomfortable nasal airflow sensor, chest band, and impedance pneumotachography often used in hospitals. The system also takes advantage of the prevalence of smartphone usage and increase the monitoring frequency of the current ECG of patients with critical illnesses.
Premature Ventricular Complexes on Screening Electrocardiogram and Risk of Ischemic Stroke
Agarwal, Sunil K.; Chao, Jennifer; Peace, Frederick; Judd, Suzanne E.; Kissela, Brett; Kleindorfer, Dawn; Howard, Virginia J.; Howard, George; Soliman, Elsayed Z.
2015-01-01
Background and Purpose Premature ventricular complexes (PVCs) detected from long-term electrocardiogram (ECG) recordings have been associated with an increased risk of ischemic stroke. Whether PVCs seen on routine ECG, commonly used in clinical practice, are associated with an increased risk of ischemic stroke remains unstudied. Methods This analysis included 24,460 participants (age 64.5+9.3 years, 55.1% Female, 40.0% African Americans) from the REasons for Geographic And Racial Differences in Stroke (REGARDS) study who were free of stroke at the time of enrollment. PVCs were ascertained from baseline ECG (2003-2007), and incident stroke cases through 2011 were confirmed by an adjudication committee. Results A total of 1,415 (5.8%) participants had at least one PVC at baseline, and 591 developed incident ischemic stroke during an average (SD) follow-up of 6.0 (2.0) years. In a Cox Proportional hazards model adjusted for age, sex, race, geographic region, education, prior heart disease, systolic blood pressure, blood pressure lowering medications, current smoking, diabetes, left ventricular hypertrophy by ECG, aspirin use and warfarin use, presence of PVCs was associated with 38% increased risk of ischemic stroke (HR (95% CI): 1.38 (1.05, 1.81)). Conclusions PVCs are common on routine screening ECGs, and are associated with an increased risk of ischemic stroke. PMID:25873602
Thanaraj, Palani; Roshini, Mable; Balasubramanian, Parvathavarthini
2016-11-14
The fetal electrocardiogram (FECG) signals are essential to monitor the health condition of the baby. Fetal heart rate (FHR) is commonly used for diagnosing certain abnormalities in the formation of the heart. Usually, non-invasive abdominal electrocardiogram (AbECG) signals are obtained by placing surface electrodes in the abdomen region of the pregnant woman. AbECG signals are often not suitable for the direct analysis of fetal heart activity. Moreover, the strength and magnitude of the FECG signals are low compared to the maternal electrocardiogram (MECG) signals. The MECG signals are often superimposed with the FECG signals that make the monitoring of FECG signals a difficult task. Primary goal of the paper is to separate the fetal electrocardiogram (FECG) signals from the unwanted maternal electrocardiogram (MECG) signals. A multivariate signal processing procedure is proposed here that combines the Multivariate Empirical Mode Decomposition (MEMD) and Independent Component Analysis (ICA). The proposed method is evaluated with clinical abdominal signals taken from three pregnant women (N= 3) recorded during the 38-41 weeks of the gestation period. The number of fetal R-wave detected (NEFQRS), the number of unwanted maternal peaks (NMQRS), the number of undetected fetal R-wave (NUFQRS) and the FHR detection accuracy quantifies the performance of our method. Clinical investigation with three test subjects shows an overall detection accuracy of 92.8%. Comparative analysis with benchmark signal processing method such as ICA suggests the noteworthy performance of our method.
Electrocardiogram findings in emergency department patients with syncope.
Quinn, James; McDermott, Daniel
2011-07-01
To determine the sensitivity and specificity of the San Francisco Syncope Rule (SFSR) electrocardiogram (ECG) criteria for determining cardiac outcomes and to define the specific ECG findings that are the most important in patients with syncope. A consecutive cohort of emergency department (ED) patients with syncope or near syncope was considered. The treating emergency physicians assessed 50 predictor variables, including an ECG and rhythm assessment. For the ECG assessment, the physicians were asked to categorize the ECG as normal or abnormal based on any changes that were old or new. They also did a separate rhythm assessment and could use any of the ECGs or available monitoring strips, including prehospital strips, when making this assessment. All patients were followed up to determine a broad composite study outcome. The final ECG criterion for the SFSR was any nonsinus rhythm or new ECG changes. In this specific study, the initial assessments in the database were used to determine only cardiac-related outcomes (arrhythmia, myocardial infarction, structural, sudden death) based on set criteria, and the authors determined the sensitivity and specificity of the ECG criteria for cardiac outcomes only. All ECGs classified as "abnormal" by the study criteria were compared to the official cardiology reading to determine specific findings on the ECG. Univariate and multivariate analysis were used to determine important specific ECG and rhythm findings. A total of 684 consecutive patients were considered, with 218 having positive ECG criteria and 42 (6%) having important cardiac outcomes. ECG criteria predicted 36 of 42 patients with cardiac outcomes, with a sensitivity of 86% (95% confidence interval [CI] = 71% to 94%), a specificity of 70% (95% CI = 66% to 74%), and a negative predictive value of 99% (95% CI = 97% to 99%). Regarding specific ECG findings, any nonsinus rhythm from any source and any left bundle conduction problem (i.e., any left bundle branch block, left anterior fascicular block, left posterior fascicular block, or QRS widening) were 2.5 and 3.5 times more likely associated with significant cardiac outcomes. The ECG criteria from the SFSR are relatively simple, and if used correctly can help predict which patients are at risk of cardiac outcomes. Furthermore, any left bundle branch block conduction problems or any nonsinus rhythms found during the ED stay should be especially concerning for physicians caring for patients presenting with syncope. © 2011 by the Society for Academic Emergency Medicine.
Gender differences in the electrocardiogram screening of athletes.
Bessem, Bram B; de Bruijn, Matthijs M C; Nieuwland, Wybe W
2017-02-01
Gender-related differences are frequently used in medicine. Electrocardiograms are also subject to such differences. This study evaluated gender differences in ECG parameters of young athletes, discussing the possible implications of these differences for ECG criteria used in the cardiovascular screening of young athletes. Observational cross-sectional study. In 2013 and 2014 all the ECGs from the cardiovascular screenings performed at University Sports Medical Centre in Groningen of the student athletes who wanted to participate in a college sports program were collected. The ECG characteristics were scored using computer-based measurements and the Seattle ECG criteria. The study population included 1436 athletes, of which 72% were male. Male athletes were older (19.3 years vs. 18.6 years), participated in sports more frequently (4.0/week vs. 3.8/week) and spent more hours per week practising sports (6.4h/week vs. 5.8h/week) than female athletes. Male athletes had significantly higher PR intervals (149ms vs. 141ms), lead voltages and QRS duration (98ms vs. 88ms). Female athletes had significantly higher resting heart rates (69/min vs. 64/min) and QTc intervals (407ms vs. 400ms). Male athletes also had significantly higher amounts of sinus bradycardia (38.3% vs. 23.0%), incomplete RBBB (15.0% vs. 3.7%), early repolarisation (4.5% vs. 1.0%) and isolated QRS voltage criteria for LVH (26.3% vs. 4.6%). All P-values were ≤0.001. ECGs of young athletes demonstrate gender-related differences. These differences could be considered in their cardiovascular screening. For the Seattle ECG criteria we advise additional research into the clinical implications of using gender-based cut-off values for the QRS duration in the intraventricular conduction delay criterion. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Electrocardiogram abnormalities and coronary calcification in postmenopausal women.
Sabour, Siamak; Grobbee, Diederick; Rutten, Annemarieke; Prokop, Mathias; Bartelink, Marie-Louise; van der Schouw, Yvonne; Bots, Michiel
2010-01-01
An electrocardiogram (ECG) can provide information on subclinical myocardial damage. The presence, and more importantly, the quantity of coronary artery calcification (CAC), relates well with the overall severity of the atherosclerotic process. A strong relation has been demonstrated between coronary calcium burden and the incidence of myocardial infarction, a relation independent of age. The aim of this study was to assess the relation of left ventricular hypertrophy (LVH) and ECG abnormalities with CAC. The study population comprised 566 postmenopausal women selected from a population-based cohort study. Information on LVH and repolarization abnormalities (T-axis and QRS-T angle) was obtained using electrocardiography. Modular ECG Analysis System (MEANS) was used to assess ECG abnormalities. The women underwent a multi detector-row computed tomography (MDCT) scan (Philips Mx 8000 IDT 16) to assess CAC. The Agatston score was used to quantify CAC; scores greater than zero were considered as the presence of coronary calcium. Logistic regression was used to assess the relation of ECG abnormality with coronary calcification. LVH was found in 2.7% (n = 15) of the women. The prevalence of T-axis abnormality was 6% (n = 34), whereas 8.5% (n = 48) had a QRS-T angle abnormality. CAC was found in 62% of the women. Compared to women with a normal T-axis, women with borderline or abnormal T-axes were 3.8 fold more likely to have CAC (95% CI: 1.4-10.2). Similarly, compared to women with a normal QRS-T angle, in women with borderline or abnormal QRS-T angle, CAC was 2.0 fold more likely to be present (95% CI: 1.0-4.1). Among women with ECG abnormalities reflecting subclinical ischemia, CAC is commonly found and may in part explain the increased coronary heart disease risk associated with these ECG abnormalities.
NASA Astrophysics Data System (ADS)
Yu, Huidan (Whitney); Chen, Xi; Chen, Rou; Wang, Zhiqiang; Lin, Chen; Kralik, Stephen; Zhao, Ye
2015-11-01
In this work, we demonstrate the validity of 4-D patient-specific computational hemodynamics (PSCH) based on 3-D time-of-flight (TOF) MR angiography (MRA) and 2-D electrocardiogram (ECG) gated phase contrast (PC) images. The mesoscale lattice Boltzmann method (LBM) is employed to segment morphological arterial geometry from TOF MRA, to extract velocity profiles from ECG PC images, and to simulate fluid dynamics on a unified GPU accelerated computational platform. Two healthy volunteers are recruited to participate in the study. For each volunteer, a 3-D high resolution TOF MRA image and 10 2-D ECG gated PC images are acquired to provide the morphological geometry and the time-varying flow velocity profiles for necessary inputs of the PSCH. Validation results will be presented through comparisons of LBM vs. 4D Flow Software for flow rates and LBM simulation vs. MRA measurement for blood flow velocity maps. Indiana University Health (IUH) Values Fund.
Tan, Robin; Perkowski, Marek
2017-01-01
Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject verification accuracy, better than the 98.33% accuracy from random forest alone and 96.31% accuracy from wavelet distance measure algorithm alone. These results demonstrate the superiority of the proposed algorithm for biometric identification, hence supporting its practicality in areas such as cloud data security, cyber-security or remote healthcare systems. PMID:28230745
Tan, Robin; Perkowski, Marek
2017-02-20
Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject verification accuracy, better than the 98.33% accuracy from random forest alone and 96.31% accuracy from wavelet distance measure algorithm alone. These results demonstrate the superiority of the proposed algorithm for biometric identification, hence supporting its practicality in areas such as cloud data security, cyber-security or remote healthcare systems.
Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System
Chou, Willy; Wang, Hsing-Yu; Huang, Yan-Jun; Pan, Jeng-Shyang
2013-01-01
Real-time monitoring of cardiac health is helpful for patients with cardiovascular disease. Many telemedicine systems based on ubiquitous computing and communication techniques have been proposed for monitoring the user's electrocardiogram (ECG) anywhere and anytime. Usually, wet electrodes are used in these telemedicine systems. However, wet electrodes require conduction gels and skin preparation that can be inconvenient and uncomfortable for users. In order to overcome this issue, a new non-contact electrode circuit was proposed and applied in developing a mobile electrocardiogram monitoring system. The proposed non-contact electrode can measure bio-potentials across thin clothing, allowing it to be embedded in a user's normal clothing to monitor ECG in daily life. We attempted to simplify the design of these non-contact electrodes to reduce power consumption while continuing to provide good signal quality. The electrical specifications and the performance of monitoring arrhythmia in clinical settings were also validated to investigate the reliability of the proposed design. Experimental results show that the proposed non-contact electrode provides good signal quality for measuring ECG across thin clothes. PMID:27170853
Niegowski, Maciej; Zivanovic, Miroslav
2016-03-01
We present a novel approach aimed at removing electrocardiogram (ECG) perturbation from single-channel surface electromyogram (EMG) recordings by means of unsupervised learning of wavelet-based intensity images. The general idea is to combine the suitability of certain wavelet decomposition bases which provide sparse electrocardiogram time-frequency representations, with the capacity of non-negative matrix factorization (NMF) for extracting patterns from images. In order to overcome convergence problems which often arise in NMF-related applications, we design a novel robust initialization strategy which ensures proper signal decomposition in a wide range of ECG contamination levels. Moreover, the method can be readily used because no a priori knowledge or parameter adjustment is needed. The proposed method was evaluated on real surface EMG signals against two state-of-the-art unsupervised learning algorithms and a singular spectrum analysis based method. The results, expressed in terms of high-to-low energy ratio, normalized median frequency, spectral power difference and normalized average rectified value, suggest that the proposed method enables better ECG-EMG separation quality than the reference methods. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Identifying UMLS concepts from ECG Impressions using KnowledgeMap
Denny, Joshua C.; Spickard, Anderson; Miller, Randolph A; Schildcrout, Jonathan; Darbar, Dawood; Rosenbloom, S. Trent; Peterson, Josh F.
2005-01-01
Electrocardiogram (ECG) impressions represent a wealth of medical information for potential decision support and drug-effect discovery. Much of this information is inaccessible to automated methods in the free-text portion of the ECG report. We studied the application of the KnowledgeMap concept identifier (KMCI) to map Unified Medical Language System (UMLS) concepts from ECG impressions. ECGs were processed by KMCI and the results scored for accuracy by multiple raters. Reviewers also recorded unidentified concepts through the scoring interface. Overall, KMCI correctly identified 1059 out of 1171 concepts for a recall of 0.90. Precision, indicating the proportion of ECG concepts correctly identified, was 0.94. KMCI was particularly effective at identifying ECG rhythms (330/333), perfusion changes (65/66), and noncardiac medical concepts (11/11). In conclusion, KMCI is an effective method for mapping ECG impressions to UMLS concepts. PMID:16779029
[An Improved Cubic Spline Interpolation Method for Removing Electrocardiogram Baseline Drift].
Wang, Xiangkui; Tang, Wenpu; Zhang, Lai; Wu, Minghu
2016-04-01
The selection of fiducial points has an important effect on electrocardiogram(ECG)denoise with cubic spline interpolation.An improved cubic spline interpolation algorithm for suppressing ECG baseline drift is presented in this paper.Firstly the first order derivative of original ECG signal is calculated,and the maximum and minimum points of each beat are obtained,which are treated as the position of fiducial points.And then the original ECG is fed into a high pass filter with 1.5Hz cutoff frequency.The difference between the original and the filtered ECG at the fiducial points is taken as the amplitude of the fiducial points.Then cubic spline interpolation curve fitting is used to the fiducial points,and the fitting curve is the baseline drift curve.For the two simulated case test,the correlation coefficients between the fitting curve by the presented algorithm and the simulated curve were increased by 0.242and0.13 compared with that from traditional cubic spline interpolation algorithm.And for the case of clinical baseline drift data,the average correlation coefficient from the presented algorithm achieved 0.972.
Educational Software Applied in Teaching Electrocardiogram: A Systematic Review
Chaves, Rafael O.; de Souza, Érica F.; Seruffo, Marcos C. R.; Francês, Carlos R. L.
2018-01-01
Background The electrocardiogram (ECG) is the most used diagnostic tool in medicine; in this sense, it is essential that medical undergraduates learn how to interpret it correctly while they are still on training. Naturally, they go through classic learning (e.g., lectures and speeches). However, they are not often efficiently trained in analyzing ECG results. In this regard, methodologies such as other educational support tools in medical practice, such as educational software, should be considered a valuable approach for medical training purposes. Methods We performed a literature review in six electronic databases, considering studies published before April 2017. The resulting set comprises 2,467 studies. From this collection, 12 studies have been selected, initially, whereby we carried out a snowballing process to identify other relevant studies through the reference lists of these studies, resulting in five relevant studies, making up a total of 17 articles that passed all stages and criteria. Results The results show that 52.9% of software types were tutorial and 58.8% were designed to be run locally on a computer. The subjects were discussed together with a greater focus on the teaching of electrophysiology and/or cardiac physiology, identifying patterns of ECG and/or arrhythmias. Conclusions We found positive results with the introduction of educational software for ECG teaching. However, there is a clear need for using higher quality research methodologies and the inclusion of appropriate controls, in order to obtain more precise conclusions about how beneficial the inclusion of such tools can be for the practices of ECG interpretation. PMID:29736398
Rural emergency medical technician pre-hospital electrocardiogram transmission.
Powell, A M; Halon, J M; Nelson, J
2014-01-01
Emergent care of the acute heart attack patient continues to be at the forefront of quality and cost reduction strategies throughout the healthcare industry. Although the average cardiac door-to-balloon (D2B) times have decreased substantially over the past few years, there are still vast disparities found in D2B times in populations that reside in rural areas. Such disparities are mostly related to prolonged travel time and subsequent delays in cardiac catherization lab team activation. Urban ambulance companies that are routinely staffed with paramedic level providers have been successful in the implementation of pre-hospital 12-lead electrocardiogram (ECG) protocols as a strategy to reduce D2B times. The authors sought to evaluate the evidence related to the risk and benefits associated with the replication of an ECG transmission protocol in a small rural emergency medical service. The latter is staffed with emergency medical technician-basics (EMT-B), emergency medical technician-advanced (EMT-A), and emergency medical technician-intermediate (EMT-I) level. The evidence reviewed was limited to studies with relevant data regarding the challenges and complexities of the ECG transmission process, the difficulties associated with ECG transmission in rural settings, and ECG transmission outcomes by provider level. The evidence supports additional research to further evaluate the feasibility of ECG transmission at the non-paramedic level. Multiple variables must be investigated including equipment cost, utilization, and rural transmission capabilities. Clearly, pre-hospital ECG transmission and early activation of the cardiac catheterization laboratory are critical components to successfully decreasing D2B times.
Farzal, Zainab; Walsh, Jonathan; Ahmad, Faisal I; Roberts, Jason; Ferns, Sunita J; Zdanski, Carlton J
2018-03-01
Objective The purpose is to determine the prevalence of electrocardiogram (ECG) abnormalities, including borderline and prolonged QT, among screened children with sensorineural hearing loss (SNHL) and to analyze their subsequent medical workup. Study Design Institutional Review Board-approved case series with chart review. Setting Tertiary academic center. Subjects and Methods Cases from 1996 to 2014 involving pediatric patients (N = 1994) with SNHL were analyzed. Abnormal ECGs were categorized as borderline/prolonged QT or other. A board-certified pediatric cardiologist retrospectively determined the clinical significance of ECG changes. For follow-up analysis, children with heart disease, known syndromes, or inaccessible records were excluded. Results Among 772 children who had ECGs, 215 (27.8%) had abnormal results: 35 (4.5%) with QT abnormalities and 180 (23.3%) with other abnormalities. For children with QT abnormalities meeting inclusion criteria (n = 30), follow-up measures included cardiology referral (46.6%), repeat ECG by ear, nose, and throat (ENT) specialist (20%), clearance by ENT specialist with clinical correlation and/or comparison with old ECGs (20%), and pediatrician follow-up (6.7%). Documentation of further workup by ENT or referral was absent for 6.7%. For children with other ECG changes meeting inclusion criteria (n = 136), abnormalities were documented for 57 (41.9%); normal QT without other abnormality was documented for 18 (13.2%). The most common follow-up referrals were to pediatricians (16.9%) and cardiologists (10.3%). Among patients with clinically significant non-QT abnormalities mandating further evaluation (n = 122), 38 (31.1%) had documented follow-up in medical records. Conclusion There is a high prevalence of ECG abnormalities among children with congenital SNHL. If findings are confirmed by future studies, screening should be considered for congenital unilateral or bilateral SNHL, regardless of severity. We describe a standardized protocol for ECG screening/follow-up.
Human Characteristics and Measures in Systems Design
2003-01-01
Electrodermal Skin conductance Field/lab $ * activity and electrode response EKG/ECG Electrocardiogram ECG electrodes- Field/la:h $ * HR, HRV Heart rate...illumination, motion, etc.). It may also be caused by psychological pressures (e.g., anxiety , anger/hostility, the "fight or flight" syndrome, threat
Katheria, Anup; Rich, Wade; Finer, Neil
2012-11-01
To compare the time required to obtain a continuous audible heart rate signal from an electrocardiogram (ECG) monitor and pulse oximeter (PO) in infants requiring resuscitation. Infants who had both ECG and PO placed during resuscitation were analyzed using video and analog recordings. The median times from arrival until the ECG electrodes and PO sensor were placed, and the time to achieve audible tones from the devices, were compared. Forty-six infants had ECG and PO data. Thirty infants were very low birth weight (23-30 weeks). There was a difference in the median total time to place either device (26 vs 38 seconds; P = .04), and a difference (P < .001) in the time to achieve an audible heart rate signal after ECG lead (2 seconds) versus PO probe (24 seconds) placement. In infants weighing >1500 g (n = 16), the median time (interquartile range) to place the ECG was 20 seconds (14-43) whereas the time to place the PO was 36 seconds (28-56) (P = .74). The median times (interquartile range) to acquire a signal from the ECG and PO were 4 seconds (1-6) and 32 seconds (15-40, P = .001), respectively. During the first minutes of resuscitation, 93% of infants had an ECG heart rate compared with only 56% for PO. Early application of ECG electrodes during infant resuscitation can provide the resuscitation team with a continuous audible heart rate, and its use may improve the timeliness of appropriate critical interventions.
[The relationship of ECG and pregnancy outcome of older pregnant woman in late pregnancy].
Zhao, Xiao-Qin; Wang, Chun-Guang; Song, Yu-Xia; Jiao, Hong
2014-01-01
To observe the changes of electrocardiogram (ECG) and pregnancy outcome of the late pregnancy women. Late pregnancy women were divided into two groups by age: over 35 group and under 35 group. The incidence of abnormal electrocardiogram was recorded when the patients were subjected to routine ECG examination. Then the pregnancy, delivery outcome and if there's low birth weight newborn were recorded later. The incidence of abnormal ECG in over 35 group was significantly higher than that in under 35 group (P < 0.05). And the incidence of ST segment changes, arrhythmia in the group of former was higher than that in the group of latter (P < 0.05). Among the different type of arrhythmia, the incidence of sinus bradycardia and ventricular premature beat in the group of former were higher than those in the group of latter (P < 0.05). But the incidence of sinus tachycardia in the former group was obviously lower than that in the latter group (P < 0.05). The incidence of pregnancy loss in over 35 with abnormal ECG group was significantly higher than that in under 35 with normal or abnormal ECG groups (P < 0.05). The incidence of premature birth in over 35 with abnormal ECG group was significantly higher than that in over 35 with normal ECG group (P < 0.05). The incidence of low body weight in over 35 with abnormal ECG group was significantly higher than that in under 35 with normal ECG group (P < 0.05). The late pregnancy women with the age of over 35 are more likely to have ECG abnormalities, such as arrhythmia, myocardial ischemia and so on. The older pregnant women with abnormal ECG easily suffer from pregnancy losing, premature birth and having a low birth weight baby.
The effect of sport on computerized electrocardiogram measurements in college athletes.
Gademan, Maaike G J; Uberoi, Abhimanyu; Le, Vy-Van; Mandic, Sandra; van Oort, Eddy R; Myers, Jonathan; Froelicher, Victor F
2012-02-01
Broad criteria for abnormal electrocardiogram (ECG) findings, requiring additional testing, have been recommended for preparticipation exams (PPE) of athletes. As these criteria have not considered the sport in which athletes participate, we examined the effect of sports on the computerized ECG measurements obtained in college athletes. During the Stanford 2007 PPE, computerized 12-lead ECGs (Schiller AG) were obtained in 641 athletes (350 male/291 female, age 19.5 ± 2 years). Athletes were engaged in 22 different sports and were grouped into 16 categories: baseball/softball, basketball, crew, crosscountry, fencing, field events, football linemen, football other positions, golf, gymnastics, racquet sports, sailing, track/field, volleyball, water sports, and wrestling. The analysis focused on ECG leads V2, aVF and V5 which provide a three-dimensional representation of the heart's electrical activity. As marked ECG differences exist between males and females, the data are presented by gender. In males, ANOVA analysis yielded significant ECG differences between sports for heart rate, QRS duration, QTc, J-amplitude in V2 and V5, spatial vector length (SVL) of the P wave, SVL R wave, and SVL T wave, and RS(sum) (p < 0.05). In females ECG differences between sports were found for heart rate, QRS duration, QRS axis and SVL T wave (p < 0.05). Poor correlations were found between body dimensions and ECG measurements (r < 0.50). Significant ECG changes exist between college athletes participating in different sports, and these differences were more apparent in males than females. Therefore, sport-specific ECG criteria for abnormal ECG findings should be developed to obtain a more useful approach to ECG screening in athletes.
A method of ECG template extraction for biometrics applications.
Zhou, Xiang; Lu, Yang; Chen, Meng; Bao, Shu-Di; Miao, Fen
2014-01-01
ECG has attracted widespread attention as one of the most important non-invasive physiological signals in healthcare-system related biometrics for its characteristics like ease-of-monitoring, individual uniqueness as well as important clinical value. This study proposes a method of dynamic threshold setting to extract the most stable ECG waveform as the template for the consequent ECG identification process. With the proposed method, the accuracy of ECG biometrics using the dynamic time wraping for difference measures has been significantly improved. Analysis results with the self-built electrocardiogram database show that the deployment of the proposed method was able to reduce the half total error rate of the ECG biometric system from 3.35% to 1.45%. Its average running time on the platform of android mobile terminal was around 0.06 seconds, and thus demonstrates acceptable real-time performance.
Peel, Sarah A; Hussain, Tarique; Cecelja, Marina; Abbas, Abeera; Greil, Gerald F; Chowienczyk, Philip; Spector, Tim; Smith, Alberto; Waltham, Matthew; Botnar, Rene M
2011-11-01
To accelerate and optimize black blood properties of the quadruple inversion recovery (QIR) technique for imaging the abdominal aortic wall. QIR inversion delays were optimized for different heart rates in simulations and phantom studies by minimizing the steady state magnetization of blood for T(1) = 100-1400 ms. To accelerate and improve black blood properties of aortic vessel wall imaging, the QIR prepulse was combined with zoom imaging and (a) "traditional" and (b) "trailing" electrocardiogram (ECG) triggering. Ten volunteers were imaged pre- and post-contrast administration using a conventional ECG-triggered double inversion recovery (DIR) and the two QIR implementations in combination with a zoom-TSE readout. The QIR implemented with "trailing" ECG-triggering resulted in consistently good blood suppression as the second inversion delay was timed during maximum systolic flow in the aorta. The blood signal-to-noise ratio and vessel wall to blood contrast-to-noise ratio, vessel wall sharpness, and image quality scores showed a statistically significant improvement compared with the traditional QIR implementation with and without ECG-triggering. We demonstrate that aortic vessel wall imaging can be accelerated with zoom imaging and that "trailing" ECG-triggering improves black blood properties of the aorta which is subject to motion and variable blood flow during the cardiac cycle. Copyright © 2011 Wiley Periodicals, Inc.
"Virtual" Experiment for Understanding the Electrocardiogram and the Mean Electrical Axis.
ERIC Educational Resources Information Center
Anderson, Jamie; DiCarlo, Stephen E.
2000-01-01
Describes a virtual experiment designed to introduce students to the theory and application of the electrocardiogram (ECG) and the mean electrical axis (MEA). Students are asked to reduce and analyze data, calculate and plot the MEA, and answer questions in the inquiry-based, experimental activity. (Author/WRM)
Electrocardiogram reading: a randomized study comparing 2 e‑learning methods for medical students.
Kopeć, Grzegorz; Waligóra, Marcin; Pacia, Michał; Chmielak, Wojciech; Stępień, Agnieszka; Janiec, Sebastian; Magoń, Wojciech; Jonas, Kamil; Podolec, Piotr
2018-02-28
INTRODUCTION Interpretation of the electrocardiogram (ECG) is an essential skill in most medical specialties; however, the best method of teaching how to read ECGs has not been determined. OBJECTIVES The aim of the study was to compare the effectiveness of collaborative (C‑eL) and self (S‑eL) e‑learning of ECG reading among medical students. PATIENTS AND METHODS A total of 60 fifth‑year medical students were randomly assigned to the C‑eL and S‑eL groups. S‑eL students received 15 ECG recordings with a comprehensive description by email (one every 48 hours), while C‑eL students received the same ECG recordings without description. C‑eL students were expected to analyze each ECG together within the subgroups using an internet platform and to submit the interpretation within 48 hours. Afterwards, they received a description of each ECG. C‑eL students' activity was assessed based on the number of words written on the internet platform during discussion. A final test consisted of 10 theoretical questions and 10 ECG recordings. The final score was a sum of points obtained for the interpretation of ECG recordings. The main endpoint of the study was the number of students whose final score was 56% or higher. RESULTS The final test was completed by 53 students (88.3%). The main endpoint was achieved in 20 C‑eL students (77%) and in 13 S‑eL students (48.1%), P = 0.03. The final score was 6.4 (interquartile range [IQR], 5.8-7.6) in the C‑eL group and 5.6 (IQR, 4.2-7.2) in the S‑eL group, P = 0.04. It correlated with the results of the theoretical test and students' activity during C‑eL (r = 0.42, P = 0.002 and r = 0.4, P = 0.04, respectively). CONCLUSIONS C‑eL of ECG reading among fifth‑year medical students is superior to S‑eL.
Brunetti, Natale Daniele; De Gennaro, Luisa; Dellegrottaglie, Giulia; Amoruso, Daniele; Antonelli, Gianfranco; Di Biase, Matteo
2011-11-01
In patients with a major cardiac event, the first priority is to minimize time-to-treatment. For many patients, the first and fastest contact with the health system is through emergency medical services (EMS). However, delay to treatment is still significant in developed countries, and international guidelines therefore recommend that EMS use prehospital electrocardiogram (ECG). Many communities are implementing prehospital ECG programs, with different technical solutions. We report on a region-wide prehospital ECG telecardiology program that involved 233,657 patients from all over Apulia (4 million inhabitants), Italy, who called the public regional free EMS telephone number "118." Prehospital ECG was transmitted by mobile phone to a single regional telecardiology "hub" where a cardiologist available 24/7 promptly reported the ECG, having a briefing with on-scene EMS personnel and EMS district central; patients were then directed to fibrinolysis or primary percutaneous coronary intervention (PCI) as appropriate. Patients were >70 years in 51% of cases, and 55% of prehospital ECGs were unremarkable; the remaining 45% showed signs suggesting acute coronary syndrome (ACS) in 18%, arrhythmias in 20%, and minor findings in 62%. In cases of suspected ACS (chest pain), ECG findings were normal in 77% of patients; 74% of subjects with suspected ACS were screened within 30' from the onset of symptoms. A regional single telecardiology hub providing prehospital ECG for a sole regional public EMS provides an example of a prehospital ECG network optimizing quality of ECG report and uniformity of EMS assistance in a large region-wide network.
DOT National Transportation Integrated Search
1974-05-01
A resting 'normal' ECG can coexist with known angina pectoris, positive angiocardiography and previous myocardial infarction. In contemporary exercise ECG tests, a false positive/false negative total error of 10% is not unusual. Research aimed at imp...
Computer analysis of Holter electrocardiogram.
Yanaga, T; Adachi, M; Sato, Y; Ichimaru, Y; Otsuka, K
1994-10-01
Computer analysis is indispensable for the interpretation of Holter ECG, because it includes a large quantity of data. Computer analysis of Holter ECG is similar to that of conventional ECG, however, in computer analysis of Holter ECG, there are some difficulties such as many noise, limited analyzing time and voluminous data. The main topics in computer analysis of Holter ECG will be arrhythmias, ST-T changes, heart rate variability, QT interval, late potential and construction of database. Although many papers have been published on the computer analysis of Holter ECG, some of the papers was reviewed briefly in the present paper. We have studied on computer analysis of VPCs, ST-T changes, heart rate variability, QT interval and Cheyne-Stokes respiration during 24-hour ambulatory ECG monitoring. Further, we have studied on ambulatory palmar sweating for the evaluation of mental stress during a day. In future, the development of "the integrated Holter system", which enables the evaluation of ventricular vulnerability and modulating factor such as psychoneural hypersensitivity may be important.
Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing
2012-04-01
The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment. © 2012 American Institute of Physics
NASA Astrophysics Data System (ADS)
Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing
2012-04-01
The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment.
Real-Time Monitoring and Analysis of Zebrafish Electrocardiogram with Anomaly Detection.
Lenning, Michael; Fortunato, Joseph; Le, Tai; Clark, Isaac; Sherpa, Ang; Yi, Soyeon; Hofsteen, Peter; Thamilarasu, Geethapriya; Yang, Jingchun; Xu, Xiaolei; Han, Huy-Dung; Hsiai, Tzung K; Cao, Hung
2017-12-28
Heart disease is the leading cause of mortality in the U.S. with approximately 610,000 people dying every year. Effective therapies for many cardiac diseases are lacking, largely due to an incomplete understanding of their genetic basis and underlying molecular mechanisms. Zebrafish ( Danio rerio ) are an excellent model system for studying heart disease as they enable a forward genetic approach to tackle this unmet medical need. In recent years, our team has been employing electrocardiogram (ECG) as an efficient tool to study the zebrafish heart along with conventional approaches, such as immunohistochemistry, DNA and protein analyses. We have overcome various challenges in the small size and aquatic environment of zebrafish in order to obtain ECG signals with favorable signal-to-noise ratio (SNR), and high spatial and temporal resolution. In this paper, we highlight our recent efforts in zebrafish ECG acquisition with a cost-effective simplified microelectrode array (MEA) membrane providing multi-channel recording, a novel multi-chamber apparatus for simultaneous screening, and a LabVIEW program to facilitate recording and processing. We also demonstrate the use of machine learning-based programs to recognize specific ECG patterns, yielding promising results with our current limited amount of zebrafish data. Our solutions hold promise to carry out numerous studies of heart diseases, drug screening, stem cell-based therapy validation, and regenerative medicine.
Real-Time Monitoring and Analysis of Zebrafish Electrocardiogram with Anomaly Detection
Lenning, Michael; Fortunato, Joseph; Le, Tai; Clark, Isaac; Sherpa, Ang; Yi, Soyeon; Hofsteen, Peter; Thamilarasu, Geethapriya; Yang, Jingchun; Xu, Xiaolei; Hsiai, Tzung K.; Cao, Hung
2017-01-01
Heart disease is the leading cause of mortality in the U.S. with approximately 610,000 people dying every year. Effective therapies for many cardiac diseases are lacking, largely due to an incomplete understanding of their genetic basis and underlying molecular mechanisms. Zebrafish (Danio rerio) are an excellent model system for studying heart disease as they enable a forward genetic approach to tackle this unmet medical need. In recent years, our team has been employing electrocardiogram (ECG) as an efficient tool to study the zebrafish heart along with conventional approaches, such as immunohistochemistry, DNA and protein analyses. We have overcome various challenges in the small size and aquatic environment of zebrafish in order to obtain ECG signals with favorable signal-to-noise ratio (SNR), and high spatial and temporal resolution. In this paper, we highlight our recent efforts in zebrafish ECG acquisition with a cost-effective simplified microelectrode array (MEA) membrane providing multi-channel recording, a novel multi-chamber apparatus for simultaneous screening, and a LabVIEW program to facilitate recording and processing. We also demonstrate the use of machine learning-based programs to recognize specific ECG patterns, yielding promising results with our current limited amount of zebrafish data. Our solutions hold promise to carry out numerous studies of heart diseases, drug screening, stem cell-based therapy validation, and regenerative medicine. PMID:29283402
Classification of cardiac arrhythmias using competitive networks.
Leite, Cicilia R M; Martin, Daniel L; Sizilio, Glaucia R A; Dos Santos, Keylly E A; de Araujo, Bruno G; Valentim, Ricardo A M; Neto, Adriao D D; de Melo, Jorge D; Guerreiro, Ana M G
2010-01-01
Information generated by sensors that collect a patient's vital signals are continuous and unlimited data sequences. Traditionally, this information requires special equipment and programs to monitor them. These programs process and react to the continuous entry of data from different origins. Thus, the purpose of this study is to analyze the data produced by these biomedical devices, in this case the electrocardiogram (ECG). Processing uses a neural classifier, Kohonen competitive neural networks, detecting if the ECG shows any cardiac arrhythmia. In fact, it is possible to classify an ECG signal and thereby detect if it is exhibiting or not any alteration, according to normality.
Sparse electrocardiogram signals recovery based on solving a row echelon-like form of system.
Cai, Pingmei; Wang, Guinan; Yu, Shiwei; Zhang, Hongjuan; Ding, Shuxue; Wu, Zikai
2016-02-01
The study of biology and medicine in a noise environment is an evolving direction in biological data analysis. Among these studies, analysis of electrocardiogram (ECG) signals in a noise environment is a challenging direction in personalized medicine. Due to its periodic characteristic, ECG signal can be roughly regarded as sparse biomedical signals. This study proposes a two-stage recovery algorithm for sparse biomedical signals in time domain. In the first stage, the concentration subspaces are found in advance. Then by exploiting these subspaces, the mixing matrix is estimated accurately. In the second stage, based on the number of active sources at each time point, the time points are divided into different layers. Next, by constructing some transformation matrices, these time points form a row echelon-like system. After that, the sources at each layer can be solved out explicitly by corresponding matrix operations. It is noting that all these operations are conducted under a weak sparse condition that the number of active sources is less than the number of observations. Experimental results show that the proposed method has a better performance for sparse ECG signal recovery problem.
Ţarălungă, Dragoş-Daniel; Ungureanu, Georgeta-Mihaela; Gussi, Ilinca; Strungaru, Rodica; Wolf, Werner
2014-01-01
Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state. Many signal processing methods for cancelling the PLI from biopotentials are available in the literature. In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices.
Ţarălungă, Dragoş-Daniel; Ungureanu, Georgeta-Mihaela; Gussi, Ilinca; Strungaru, Rodica; Wolf, Werner
2014-01-01
Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state. Many signal processing methods for cancelling the PLI from biopotentials are available in the literature. In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices. PMID:24660020
Tripolar Laplacian electrocardiogram and moment of activation isochronal mapping.
Besio, W; Chen, T
2007-05-01
The electrocardiogram (ECG) provides useful global temporal assessment of the cardiac activity, but has limited spatial capabilities. The Laplacian electrocardiogram (LECG), an improvement over the ECG, provides high spatiotemporal distributed information about cardiac electrical activation. We designed and developed LECG tripolar concentric ring electrode active sensors based on the finite element algorithm 'nine-point method' (NPM). The active sensors were used in an array of 6 by 12 (72) locations to record bipolar and tripolar LECG from the body surface over the anterolateral chest. Compared to bipolar LECG, tripolar LECG showed significantly higher spatial selectivity which may be helpful in inferring information about cardiac activations detected on the body surface. In this study the moment of activation (MOA), an indicator of a depolarization wave passing below the active sensors, was used to surmise possible timing information of the cardiac electrical activation below the active sensors' recording sites. The MOA on the body surface was used to generate isochronal maps that may some day be used by clinicians in diagnosing arrhythmias and assessing the efficacy of therapies.
Microprocessor-based cardiotachometer
NASA Technical Reports Server (NTRS)
Crosier, W. G.; Donaldson, J. A.
1981-01-01
Instrument operates reliably even with stress-test electrocardiogram (ECG) signals subject to noise, baseline wandering, and amplitude change. It records heart rate from preamplified, single-lead ECG input signal and produces digital and analog heart-rate outputs which are fed elsewhere. Analog hardware processes ECG input signal, producing 10-ms pulse for each heartbeat. Microprocessor analyzes resulting pulse train, identifying irregular heartbeats and maintaining stable output during lead switching. Easily modified computer program provides analysis.
A new statistical PCA-ICA algorithm for location of R-peaks in ECG.
Chawla, M P S; Verma, H K; Kumar, Vinod
2008-09-16
The success of ICA to separate the independent components from the mixture depends on the properties of the electrocardiogram (ECG) recordings. This paper discusses some of the conditions of independent component analysis (ICA) that could affect the reliability of the separation and evaluation of issues related to the properties of the signals and number of sources. Principal component analysis (PCA) scatter plots are plotted to indicate the diagnostic features in the presence and absence of base-line wander in interpreting the ECG signals. In this analysis, a newly developed statistical algorithm by authors, based on the use of combined PCA-ICA for two correlated channels of 12-channel ECG data is proposed. ICA technique has been successfully implemented in identifying and removal of noise and artifacts from ECG signals. Cleaned ECG signals are obtained using statistical measures like kurtosis and variance of variance after ICA processing. This analysis also paper deals with the detection of QRS complexes in electrocardiograms using combined PCA-ICA algorithm. The efficacy of the combined PCA-ICA algorithm lies in the fact that the location of the R-peaks is bounded from above and below by the location of the cross-over points, hence none of the peaks are ignored or missed.
Portable electrocardiogram device using Android smartphone.
Brucal, S G E; Clamor, G K D; Pasiliao, L A O; Soriano, J P F; Varilla, L P M
2016-08-01
Portable electrocardiogram (ECG) capturing device can be interfaced to a smart phone installed with an android-based application (app). This app processes and analyses the data sent by the device to provide an interpretation of the patient/user's heart current condition (e.g.: beats per minute, heart signal waveform, R-R interval). The ECG recorded by the app is stored in the smart phone's Secure Digital (SD) card and cloud storage which can be accessed remotely by a physician to aid in providing medical diagnosis. The project aims to help patients living at a far distance from hospitals and experience difficulty in consulting their physician for regular check-ups, and assist doctors in regularly monitoring their patient's heart condition. The hardware data acquisition device and software application were subjected to trials in a clinic with volunteer-patients to measure the ECG and heart rate, data saving speed on the SD card, success rate of the saved data and uploaded file. Different ECG tests using the project prototype were done for 12 patients/users and yielded a reading difference of 7.61% in an R-R interval reading and 5.35% in heart rate reading as compared with the cardiologist's conventional 12-electrode ECG machine. Using the developed ECG device, it took less than 5 seconds to save ECG reading using SD card and approximately 2 minutes to upload via cloud.
Cardiac Electrophysiology: Normal and Ischemic Ionic Currents and the ECG
ERIC Educational Resources Information Center
Klabunde, Richard E.
2017-01-01
Basic cardiac electrophysiology is foundational to understanding normal cardiac function in terms of rate and rhythm and initiation of cardiac muscle contraction. The primary clinical tool for assessing cardiac electrical events is the electrocardiogram (ECG), which provides global and regional information on rate, rhythm, and electrical…
ECG Monitoring in Cardiac Rehabilitation: Is It Needed?
ERIC Educational Resources Information Center
Greenland, Philip; Pomilla, Paul V.
1989-01-01
Discusses the controversial use of continuous electrocardiogram (ECG) monitoring as a safety measure in cardiac rehabilitation exercise programs. Little evidence substantiates its value for all patients during exercise. In the absence of empirical evidence documenting the worth of this expensive procedure, it is recommended for use with high-risk…
Barrios, V; Calderón, A; Coca, A; González-Juanatey, J R; Sarríá, A; Rodríguez-Padial, L
2011-09-01
Despite its low sensitivity, the electrocardiogram (ECG) is the tool used the most in the daily practice for detection of left ventricular hypertrophy (LVH). This study has aimed to assess the impact of the computerized interpretation of the ECG on the diagnosis of LVH in the practical clinical setting. ELECTROPRES is a project based on a free access computer platform that permits an online interpretation of the electrocardiogram. It includes 19 different left LVH criteria previously validated by echocardiography in a substudy. We analyzed the data from the first 669 patients with essential arterial hypertension (ATH) included in the ELECTROPRES platform from 21 primary care centers in 9 of the 17 Spanish autonomous communities. Up to April 2010, a cohort of 669 hypertensive patients (51.7% women), with a mean age of 66.3±11.89 years, was analyzed. The mean evolution of the disease was 8 years, and the patients had been receiving an average of 2.4 antihypertensive agents. Systolic blood pressure was 139±17 mmHg and diastolic blood pressure 76±11. The ECG-known frequency of LVH was 3%. The prevalence of LVH increased up to 33.3% (P<0.001) with the ELECTROPRES platform. When all the criteria were independently examined, the Lewis index (R-I+S-III) and the Cornell product [(R-aVL+S-V3 (+6 for women)] were those in which the most cases of left ventricular hypertrophy were detected (24.8% and 13.3%, respectively). The Lewis index and the Cornell product were the criteria that detected more cases of left ventricular hypertrophy, regardless of the AHT stage and of the presence of cardiovascular complications. The ECG computerized reading (ELECTROPRES platform) significantly increases detection of left ventricular hypertrophy in a population of essential hypertense subjects compared to conventional detection with the ECG by the physician in the usual clinical practice setting. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan
2016-02-01
This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG + STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.
Carrault, G; Cordier, M-O; Quiniou, R; Wang, F
2003-07-01
This paper proposes a novel approach to cardiac arrhythmia recognition from electrocardiograms (ECGs). ECGs record the electrical activity of the heart and are used to diagnose many heart disorders. The numerical ECG is first temporally abstracted into series of time-stamped events. Temporal abstraction makes use of artificial neural networks to extract interesting waves and their features from the input signals. A temporal reasoner called a chronicle recogniser processes such series in order to discover temporal patterns called chronicles which can be related to cardiac arrhythmias. Generally, it is difficult to elicit an accurate set of chronicles from a doctor. Thus, we propose to learn automatically from symbolic ECG examples the chronicles discriminating the arrhythmias belonging to some specific subset. Since temporal relationships are of major importance, inductive logic programming (ILP) is the tool of choice as it enables first-order relational learning. The approach has been evaluated on real ECGs taken from the MIT-BIH database. The performance of the different modules as well as the efficiency of the whole system is presented. The results are rather good and demonstrate that integrating numerical techniques for low level perception and symbolic techniques for high level classification is very valuable.
[Diagnostic performance of surface electrocardiogram in early detection of chagasic cardiomyopathy].
Bochard-Villanueva, Bruno; Estornell-Erill, Jordi; Fabregat-Andrés, Óscar; García-González, Pilar; Morell-Cabedo, Salvador; Ridocci-Soriano, Francisco
2015-03-15
Contrast-enhanced cardiac magnetic resonance imaging (CMR) allows early detection of myocardial involvement by Trypanosoma cruzi infection. The aim of our study was to assess the diagnostic performance of the surface electrocardiogram (ECG) in the early detection of Chagas' cardiomyopathy (CCM) compared with CMR. We included 43 asymptomatic patients (30 women, 42 ± 9.8 years), diagnosed of Chagas disease. The sample was divided into 2 groups according to the presence (n=17) or absence (n=26) of electrocardiographic abnormalities. All patients underwent CMR and late gadolinium enhancement (LGE) was used as a marker of early myocardial involvement. Six (14%) patients had a LGE significantly higher in the group who had electrocardiographic abnormalities (29 vs. 4%, P<.05). With CMR as the method of reference, the ECG had a sensitivity of 83% and a negative predictive value of 96% to detect CCM. ECG is a useful, inexpensive and globally available tool for the screening of CCM in asymptomatic patients but with proven myocardial involvement in CMR. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.
Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection.
Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae
2017-06-12
Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan-Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities.
Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection †
Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae
2017-01-01
Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan–Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities. PMID:28604628
Envelopment filter and K-means for the detection of QRS waveforms in electrocardiogram.
Merino, Manuel; Gómez, Isabel María; Molina, Alberto J
2015-06-01
The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper describes an offline version and a real-time implementation of a new algorithm to determine QRS localization in the ECG signal based on its envelopment and K-means clustering algorithm. The envelopment is used to obtain a signal with only QRS complexes, deleting P, T, and U waves and baseline wander. Two moving average filters are applied to smooth data. The K-means algorithm classifies data into QRS and non-QRS. The technique is validated using 22 h of ECG data from five Physionet databases. These databases were arbitrarily selected to analyze different morphologies of QRS complexes: three stored data with cardiac pathologies, and two had data with normal heartbeats. The algorithm has a low computational load, with no decision thresholds. Furthermore, it does not require any additional parameter. Sensitivity, positive prediction and accuracy from results are over 99.7%. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Novotny, Tomas; Bond, Raymond; Andrsova, Irena; Koc, Lumir; Sisakova, Martina; Finlay, Dewar; Guldenring, Daniel; Spinar, Jindrich; Malik, Marek
2017-05-01
Most contemporary 12-lead electrocardiogram (ECG) devices offer computerized diagnostic proposals. The reliability of these automated diagnoses is limited. It has been suggested that incorrect computer advice can influence physician decision-making. This study analyzed the role of diagnostic proposals in the decision process by a group of fellows of cardiology and other internal medicine subspecialties. A set of 100 clinical 12-lead ECG tracings was selected covering both normal cases and common abnormalities. A team of 15 junior Cardiology Fellows and 15 Non-Cardiology Fellows interpreted the ECGs in 3 phases: without any diagnostic proposal, with a single diagnostic proposal (half of them intentionally incorrect), and with four diagnostic proposals (only one of them being correct) for each ECG. Self-rated confidence of each interpretation was collected. Availability of diagnostic proposals significantly increased the diagnostic accuracy (p<0.001). Nevertheless, in case of a single proposal (either correct or incorrect) the increase of accuracy was present in interpretations with correct diagnostic proposals, while the accuracy was substantially reduced with incorrect proposals. Confidence levels poorly correlated with interpretation scores (rho≈2, p<0.001). Logistic regression showed that an interpreter is most likely to be correct when the ECG offers a correct diagnostic proposal (OR=10.87) or multiple proposals (OR=4.43). Diagnostic proposals affect the diagnostic accuracy of ECG interpretations. The accuracy is significantly influenced especially when a single diagnostic proposal (either correct or incorrect) is provided. The study suggests that the presentation of multiple computerized diagnoses is likely to improve the diagnostic accuracy of interpreters. Copyright © 2017 Elsevier B.V. All rights reserved.
Hartman, Nicholas D; Wheaton, Natasha B; Williamson, Kelly; Quattromani, Erin N; Branzetti, Jeremy B; Aldeen, Amer Z
2016-12-01
Reading emergent electrocardiograms (ECGs) is one of the emergency physician's most crucial tasks, yet no well-validated tool exists to measure resident competence in this skill. To assess validity of a novel tool measuring emergency medicine resident competency for interpreting, and responding to, critical ECGs. In addition, we aim to observe trends in this skill for resident physicians at different levels of training. This is a multi-center, prospective study of postgraduate year (PGY) 1-4 residents at five emergency medicine (EM) residency programs in the United States. An assessment tool was created that asks the physician to identify either the ECG diagnosis or the best immediate management. One hundred thirteen EM residents from five EM residency programs submitted completed assessment surveys, including 43 PGY-1s, 33 PGY-2s, and 37 PGY-3/4s. PGY-3/4s averaged 74.6% correct (95% confidence interval [CI] 70.9-78.4) and performed significantly better than PGY-1s, who averaged 63.2% correct (95% CI 58.0-68.3). PGY-2s averaged 69.0% (95% CI 62.2-73.7). Year-to-year differences were more pronounced in management than in diagnosis. Residency training in EM seems to be associated with improved ability to interpret "critical" ECGs as measured by our assessment tool. This lends validity evidence for the tool by correlating with a previously observed association between residency training and improved ECG interpretation. Resident skill in ECG interpretation remains less than ideal. Creation of this sort of tool may allow programs to assess resident performance as well as evaluate interventions designed to improve competency. Copyright © 2016 Elsevier Inc. All rights reserved.
Severe Hyperkalemia: Can the Electrocardiogram Risk Stratify for Short-term Adverse Events?
Durfey, Nicole; Lehnhof, Brian; Bergeson, Andrew; Durfey, Shayla N M; Leytin, Victoria; McAteer, Kristina; Schwam, Eric; Valiquet, Justin
2017-08-01
The electrocardiogram (ECG) is often used to identify which hyperkalemic patients are at risk for adverse events. However, there is a paucity of evidence to support this practice. This study analyzes the association between specific hyperkalemic ECG abnormalities and the development of short-term adverse events in patients with severe hyperkalemia. We collected records of all adult patients with potassium (K+) ≥6.5 mEq/L in the hospital laboratory database from August 15, 2010, through January 30, 2015. A chart review identified patient demographics, concurrent laboratory values, ECG within one hour of K+ measurement, treatments and occurrence of adverse events within six hours of ECG. We defined adverse events as symptomatic bradycardia, ventricular tachycardia, ventricular fibrillation, cardiopulmonary resuscitation (CPR) and/or death. Two emergency physicians blinded to study objective independently examined each ECG for rate, rhythm, peaked T wave, PR interval duration and QRS complex duration. Relative risk was calculated to determine the association between specific hyperkalemic ECG abnormalities and short-term adverse events. We included a total of 188 patients with severe hyperkalemia in the final study group. Adverse events occurred within six hours in 28 patients (15%): symptomatic bradycardia (n=22), death (n=4), ventricular tachycardia (n=2) and CPR (n=2). All adverse events occurred prior to treatment with calcium and all but one occurred prior to K + -lowering intervention. All patients who had a short-term adverse event had a preceding ECG that demonstrated at least one hyperkalemic abnormality (100%, 95% confidence interval [CI] [85.7-100%]). An increased likelihood of short-term adverse event was found for hyperkalemic patients whose ECG demonstrated QRS prolongation (relative risk [RR] 4.74, 95% CI [2.01-11.15]), bradycardia (HR<50) (RR 12.29, 95%CI [6.69-22.57]), and/or junctional rhythm (RR 7.46, 95%CI 5.28-11.13). There was no statistically significant correlation between peaked T waves and short-term adverse events (RR 0.77, 95% CI [0.35-1.70]). Our findings support the use of the ECG to risk stratify patients with severe hyperkalemia for short-term adverse events.
Severe Hyperkalemia: Can the Electrocardiogram Risk Stratify for Short-term Adverse Events?
Durfey, Nicole; Lehnhof, Brian; Bergeson, Andrew; Durfey, Shayla N.M.; Leytin, Victoria; McAteer, Kristina; Schwam, Eric; Valiquet, Justin
2017-01-01
Introduction The electrocardiogram (ECG) is often used to identify which hyperkalemic patients are at risk for adverse events. However, there is a paucity of evidence to support this practice. This study analyzes the association between specific hyperkalemic ECG abnormalities and the development of short-term adverse events in patients with severe hyperkalemia. Methods We collected records of all adult patients with potassium (K+) ≥6.5 mEq/L in the hospital laboratory database from August 15, 2010, through January 30, 2015. A chart review identified patient demographics, concurrent laboratory values, ECG within one hour of K+ measurement, treatments and occurrence of adverse events within six hours of ECG. We defined adverse events as symptomatic bradycardia, ventricular tachycardia, ventricular fibrillation, cardiopulmonary resuscitation (CPR) and/or death. Two emergency physicians blinded to study objective independently examined each ECG for rate, rhythm, peaked T wave, PR interval duration and QRS complex duration. Relative risk was calculated to determine the association between specific hyperkalemic ECG abnormalities and short-term adverse events. Results We included a total of 188 patients with severe hyperkalemia in the final study group. Adverse events occurred within six hours in 28 patients (15%): symptomatic bradycardia (n=22), death (n=4), ventricular tachycardia (n=2) and CPR (n=2). All adverse events occurred prior to treatment with calcium and all but one occurred prior to K+-lowering intervention. All patients who had a short-term adverse event had a preceding ECG that demonstrated at least one hyperkalemic abnormality (100%, 95% confidence interval [CI] [85.7–100%]). An increased likelihood of short-term adverse event was found for hyperkalemic patients whose ECG demonstrated QRS prolongation (relative risk [RR] 4.74, 95% CI [2.01–11.15]), bradycardia (HR<50) (RR 12.29, 95%CI [6.69–22.57]), and/or junctional rhythm (RR 7.46, 95%CI 5.28–11.13). There was no statistically significant correlation between peaked T waves and short-term adverse events (RR 0.77, 95% CI [0.35–1.70]). Conclusion Our findings support the use of the ECG to risk stratify patients with severe hyperkalemia for short-term adverse events. PMID:28874951
Non-invasive Foetal ECG – a Comparable Alternative to the Doppler CTG?
Reinhard, J.; Louwen, F.
2012-01-01
This review discusses the alternative of using the non-invasive foetal ECG compared with the conventionally used Doppler CTG. Non-invasive abdominal electrocardiograms (ECG) have been approved for clinical routine since 2008; subsequently they were also approved for antepartum and subpartum procedures. The first study results have been published. Non-invasive foetal ECG is especially indicated during early pregnancy, while the Doppler CTG is recommended for the vernix period. Beyond the vernix period no difference has been recorded in the success rate of either approach. The foetal ECG signal quality is independent of the BMI, whereas the success rate of the Doppler CTG is diminished with an increased BMI. During the first stage of labour, non-invasive foetal ECG demonstrates better signal quality; however during the second stage of labour no difference has been identified between the methods. PMID:25308981
Compression and R-wave detection of ECG/VCG data
NASA Technical Reports Server (NTRS)
Hayden, W. L.; Conover, M. F.; Bennett, W. P.
1972-01-01
Application of information theory to eliminate redundant part of electrocardiogram or vectorcardiogram is described. Operation of medical equipment to obtain three dimensional study of patient is discussed. Use of fast Fourier transform to accomplish data compression is explained.
Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System.
Li, Hongqiang; Yuan, Danyang; Wang, Youxi; Cui, Dianyin; Cao, Lu
2016-10-20
Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG) recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias.
Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System
Li, Hongqiang; Yuan, Danyang; Wang, Youxi; Cui, Dianyin; Cao, Lu
2016-01-01
Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG) recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias. PMID:27775596
Electrocardiogram Abnormalities and Coronary Calcification in Postmenopausal Women
Sabour, Siamak; Grobbee, Diederick; Rutten, Annemarieke; Prokop, Mathias; Bartelink, Marie-Louise; van der Schouw, Yvonne; Bots, Michiel
2010-01-01
Background: An electrocardiogram (ECG) can provide information on subclinical myocardial damage. The presence, and more importantly, the quantity of coronary artery calcification (CAC), relates well with the overall severity of the atherosclerotic process. A strong relation has been demonstrated between coronary calcium burden and the incidence of myocardial infarction, a relation independent of age. The aim of this study was to assess the relation of left ventricular hypertrophy (LVH) and ECG abnormalities with CAC. Methods: The study population comprised 566 postmenopausal women selected from a population-based cohort study. Information on LVH and repolarization abnormalities (T-axis and QRS-T angle) was obtained using electrocardiography. Modular ECG Analysis System (MEANS) was used to assess ECG abnormalities. The women underwent a multi detector-row computed tomography (MDCT) scan (Philips Mx 8000 IDT 16) to assess CAC. The Agatston score was used to quantify CAC; scores greater than zero were considered as the presence of coronary calcium. Logistic regression was used to assess the relation of ECG abnormality with coronary calcification. Results: LVH was found in 2.7% (n = 15) of the women. The prevalence of T-axis abnormality was 6% (n = 34), whereas 8.5% (n = 48) had a QRS-T angle abnormality. CAC was found in 62% of the women. Compared to women with a normal T-axis, women with borderline or abnormal T-axes were 3.8 fold more likely to have CAC (95% CI: 1.4–10.2). Similarly, compared to women with a normal QRS-T angle, in women with borderline or abnormal QRS-T angle, CAC was 2.0 fold more likely to be present (95% CI: 1.0–4.1). Conclusion: Among women with ECG abnormalities reflecting subclinical ischemia, CAC is commonly found and may in part explain the increased coronary heart disease risk associated with these ECG abnormalities. PMID:23074563
Asif, Irfan M; Drezner, Jonathan A
2012-01-01
Sudden cardiac death (SCD) is the leading cause of death in young athletes during exercise, and there is international agreement among major medical and sporting bodies that young athletes should undergo preparticipation cardiovascular screening. However, there is currently no universally accepted screening protocol, and substantial debate exists about what constitutes the ideal approach to preparticipation screening. The primary objective of preparticipation screening is the detection of intrinsic structural or electrical cardiovascular disorders that predispose an athlete to SCD. Considerable evidence exists suggesting that screening athletes with only a history and physical examination leaves most athletes with a serious underlying cardiovascular disease undetected and, thus, cannot adequately achieve the primary objective of screening. Preparticipating cardiovascular screening inclusive of an electrocardiogram (ECG) greatly enhances the ability to identify athletes at risk and is the only model shown to be cost-effective and may reduce the rate of SCD. The major obstacle to ECG screening in the United States is the lack of a physician workforce skilled in interpretation of an athlete's ECG. However, recent studies have demonstrated a capacity to distinguish physiologic ECG alterations in athletes from findings suggestive of underlying pathology that is both feasible and has a low false-positive rate. Efforts are underway to increase physician education in ECG interpretation. After 2 decades debating the proper screening strategy to identify athletes at risk, the weight of scientific evidence suggests that a screening program inclusive of ECG is the only strategy that merits promotion. Copyright © 2012 Elsevier Inc. All rights reserved.
Yates, Christopher; Manini, Alex F
2012-01-01
The ECG is a rapidly available clinical tool that can help clinicians manage poisoned patients. Specific myocardial effects of cardiotoxic drugs have well-described electrocardiographic manifestations. In the practice of clinical toxicology, classic ECG changes may hint at blockade of ion channels, alterations of adrenergic tone, or dysfunctional metabolic activity of the myocardium. This review will offer a structured approach to ECG interpretation in poisoned patients with a focus on clinical implications and ECG-based management recommendations in the initial evaluation of patients with acute cardiotoxicity. PMID:22708912
Model-based Bayesian filtering of cardiac contaminants from biomedical recordings.
Sameni, R; Shamsollahi, M B; Jutten, C
2008-05-01
Electrocardiogram (ECG) and magnetocardiogram (MCG) signals are among the most considerable sources of noise for other biomedical signals. In some recent works, a Bayesian filtering framework has been proposed for denoising the ECG signals. In this paper, it is shown that this framework may be effectively used for removing cardiac contaminants such as the ECG, MCG and ballistocardiographic artifacts from different biomedical recordings such as the electroencephalogram, electromyogram and also for canceling maternal cardiac signals from fetal ECG/MCG. The proposed method is evaluated on simulated and real signals.
Doxorubicin (DOX) is a widely used anthracycline anti-neoplastic drug used to treat tumors. However it has been implicated in irreversible cardiac toxicity via the generation of a proxidant semiquinone free radical, which often results in cardiomyopathy and changes in the ECG. Ac...
Algorithm for the classification of multi-modulating signals on the electrocardiogram.
Mita, Mitsuo
2007-03-01
This article discusses the algorithm to measure electrocardiogram (ECG) and respiration simultaneously and to have the diagnostic potentiality for sleep apnoea from ECG recordings. The algorithm is composed by the combination with the three particular scale transform of a(j)(t), u(j)(t), o(j)(a(j)) and the statistical Fourier transform (SFT). Time and magnitude scale transforms of a(j)(t), u(j)(t) change the source into the periodic signal and tau(j) = o(j)(a(j)) confines its harmonics into a few instantaneous components at tau(j) being a common instant on two scales between t and tau(j). As a result, the multi-modulating source is decomposed by the SFT and is reconstructed into ECG, respiration and the other signals by inverse transform. The algorithm is expected to get the partial ventilation and the heart rate variability from scale transforms among a(j)(t), a(j+1)(t) and u(j+1)(t) joining with each modulation. The algorithm has a high potentiality of the clinical checkup for the diagnosis of sleep apnoea from ECG recordings.
Predictable and reliable ECG monitoring over IEEE 802.11 WLANs within a hospital.
Park, Juyoung; Kang, Kyungtae
2014-09-01
Telecardiology provides mobility for patients who require constant electrocardiogram (ECG) monitoring. However, its safety is dependent on the predictability and robustness of data delivery, which must overcome errors in the wireless channel through which the ECG data are transmitted. We report here a framework that can be used to gauge the applicability of IEEE 802.11 wireless local area network (WLAN) technology to ECG monitoring systems in terms of delay constraints and transmission reliability. For this purpose, a medical-grade WLAN architecture achieved predictable delay through the combination of a medium access control mechanism based on the point coordination function provided by IEEE 802.11 and an error control scheme based on Reed-Solomon coding and block interleaving. The size of the jitter buffer needed was determined by this architecture to avoid service dropout caused by buffer underrun, through analysis of variations in transmission delay. Finally, we assessed this architecture in terms of service latency and reliability by modeling the transmission of uncompressed two-lead electrocardiogram data from the MIT-BIH Arrhythmia Database and highlight the applicability of this wireless technology to telecardiology.
Kwon, Sungjun; Kim, Jeehoon; Kang, Seungwoo; Lee, Youngki; Baek, Hyunjae
2014-01-01
Abstract We propose CardioGuard, a brassiere-based reliable electrocardiogram (ECG) monitoring sensor system, for supporting daily smartphone healthcare applications. It is designed to satisfy two key requirements for user-unobtrusive daily ECG monitoring: reliability of ECG sensing and usability of the sensor. The system is validated through extensive evaluations. The evaluation results showed that the CardioGuard sensor reliably measure the ECG during 12 representative daily activities including diverse movement levels; 89.53% of QRS peaks were detected on average. The questionnaire-based user study with 15 participants showed that the CardioGuard sensor was comfortable and unobtrusive. Additionally, the signal-to-noise ratio test and the washing durability test were conducted to show the high-quality sensing of the proposed sensor and its physical durability in practical use, respectively. PMID:25405527
Extraction of ECG signal with adaptive filter for hearth abnormalities detection
NASA Astrophysics Data System (ADS)
Turnip, Mardi; Saragih, Rijois. I. E.; Dharma, Abdi; Esti Kusumandari, Dwi; Turnip, Arjon; Sitanggang, Delima; Aisyah, Siti
2018-04-01
This paper demonstrates an adaptive filter method for extraction ofelectrocardiogram (ECG) feature in hearth abnormalities detection. In particular, electrocardiogram (ECG) is a recording of the heart's electrical activity by capturing a tracingof cardiac electrical impulse as it moves from the atrium to the ventricles. The applied algorithm is to evaluate and analyze ECG signals for abnormalities detection based on P, Q, R and S peaks. In the first phase, the real-time ECG data is acquired and pre-processed. In the second phase, the procured ECG signal is subjected to feature extraction process. The extracted features detect abnormal peaks present in the waveform. Thus the normal and abnormal ECG signal could be differentiated based on the features extracted.
Some regularity on how to locate electrodes for higher fECG SNRs
NASA Astrophysics Data System (ADS)
Zhang, Jie-Min; Huang, Xiao-Lin; Guan, Qun; Liu, Tie-Bing; Li, Ping; Zhao, Ying; Liu, Hong-Xing
2015-03-01
The electrocardiogram (ECG) recorded from the abdominal surface of a pregnant woman is a composite of maternal ECG, fetal ECG (fECG) and other noises, while only the fECG component is always needed by us. With different locations of electrode pairs on the maternal abdominal surface to measure fECGs, the signal-to-noise ratios (SNRs) of the recorded abdominal ECGs are also correspondingly different. Some regularity on how to locate electrodes to obtain higher fECG SNRs is needed practically. In this paper, 343 groups of abdominal ECG records were acquired from 78 pregnant women with different electrode pairs locating, and an appropriate extended research database is formed. Then the regularity on fECG SNRs corresponding to different electrode pairs locating was studied. Based on statistical analysis, it is shown that the fECG SNRs are significantly higher in certain locations than others. Reasonable explanation is also provided to the statistical result using the theories of the fetal cardiac electrical axis and the signal phase delay. Project supported by the National Natural Science Foundation of China (Grant No. 61271079) and the Supporting Plan Project of Jiangsu Province, China (Grant No. BE2010720).
Effects of asphyxia and potassium on canine and feline electrocardiograms.
Coulter, D B; Duncan, R J; Sander, P D
1975-01-01
The effects of asphyxia and potassium on the electrocardiogram (ECG), lead II, were recorded from dogs and cats anesthetized with sodium pentobarbital and halothane. Electrocardiographic recordings were made during control periods, during asphyxia (occluded endotracheal tube), during infusion of an isotonic KCl solution and during infusion of an isotonic NaCl solution. Arterial and venous blood gas partial pressures (PaCO2, PvCO2, PaO2 and and PvO2), plasma Na+ and K+ concentrations, heart rate and mean arterial blood pressure were measured during control periods, asphyxia and during the periods of infusion. The vagi were severed to assess the effect of vagal tone on the ECG changes. The characteristic ECG changes during asphyxia and the electrolyte imbalances resulting from infusion of isotonic KCl and NaCl were determined during sodium pentobarbital and halothane anesthesia in both dogs and cats. The combination of halothane and high PCO2 caused cardiac arrhythmias. Spontaneous recovery from ventricular fibrillation, as a result of hyperkalemia, was recorded from cats. Disappearance of the P waves, which is characteristic of hyperkalemia, was infrequent in this study and the U waves associated with hypokalemia were not found. Severing the vagi did not alter the ECG changes characteristic of asphyxia, hyperkalemia and hypokalemia. It was found that asphyxia and infusion of fluids high or low in potassium can produce ECG changes in both dogs and cats that can be correlated with blood gas partial pressure changes or plasma potassium concentrations. PMID:1175078
Compressed sensing system considerations for ECG and EMG wireless biosensors.
Dixon, Anna M R; Allstot, Emily G; Gangopadhyay, Daibashish; Allstot, David J
2012-04-01
Compressed sensing (CS) is an emerging signal processing paradigm that enables sub-Nyquist processing of sparse signals such as electrocardiogram (ECG) and electromyogram (EMG) biosignals. Consequently, it can be applied to biosignal acquisition systems to reduce the data rate to realize ultra-low-power performance. CS is compared to conventional and adaptive sampling techniques and several system-level design considerations are presented for CS acquisition systems including sparsity and compression limits, thresholding techniques, encoder bit-precision requirements, and signal recovery algorithms. Simulation studies show that compression factors greater than 16X are achievable for ECG and EMG signals with signal-to-quantization noise ratios greater than 60 dB.
Is there evidence for mandating electrocardiogram as part of the pre-participation examination?
Borjesson, Mats; Dellborg, Mikael
2011-01-01
The risk of sudden cardiac death may be increased up to 2.8 times in competitive athletes compared with nonathletes. The majority of sudden cardiac death cases are caused by an underlying abnormality that potentially may be identified on cardiovascular screening, depending on the specific abnormality and the content of the cardiovascular screening applied. Indeed, today, cardiac screening is universally recommended by the cardiac societies [European Society of Cardiology (ESC) and American Heart Association (AHA)] and required by the sporting bodies [Fédération Internationale de Football Association (FIFA) and Union of European Football Associations (UEFA)]. Pre-participation examination is by consensus understood to include personal history and physical examination; controversy exists regarding the usefulness and appropriateness of screening using resting 12-lead electrocardiogram (ECG), with an apparent transatlantic difference. The ESC recommends screening consisting of personal history, physical examination, and 12-lead resting ECG, whereas recommendations from the AHA includes only personal history and physical examination. There is firm scientific ground to state that the sensitivity of screening with ECG is vastly superior to, and the cost-effectiveness significantly better than, screening without ECG. Cardiac screening of elite athletes with personal history, physical examination, and ECG is cost-effective also in comparison with other well-accepted procedures of modern health care, such as dialysis and implantable cardiac defibrillators. Newly published recommendations for the interpretation of the ECG in athletes (ESC) and future studies on ECGs in athletes of different ethnicity, gender, and age may further increase the specificity of ECG in cardiac screening, refining the screening procedure and lowering the costs for additional follow-up testing. Cardiac screening without ECG is not cost-effective and may be only marginally better than no screening at all and at a considerable higher cost. The difficulties in feasibility and liability issues for recommending ECGs in some countries need to be acknowledged but must be dealt with within those countries/systems. On ethical grounds, the reasons (logistical, legal, economic) for not screening individual athletes should be clearly stated. Alas, the current evidence, as presented here, suggests that the ECG should be mandatory in pre-participation screening of athletes.
Electrocardiographic recognition of right ventricular hypertrophy.
Nikus, Kjell; Pérez-Riera, Andrés Ricardo; Konttila, Kaari; Barbosa-Barros, Raimundo
The electrocardiogram (ECG) is a relatively insensitive tool for the detection of right ventricular hypertrophy (RVH), but some criteria have high specificity. The recommended ECG screening criteria for RVH are not sufficiently sensitive or specific for screening for mild RVH in adults without clinical cardiovascular disease. The greatest accuracy of the ECG is in congenital heart disease, with intermediate accuracy in acquired heart disease and primary pulmonary hypertension in adults. Copyright © 2017 Elsevier Inc. All rights reserved.
Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J
2016-04-01
Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of -4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and -5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of -5.6 to 5.2 bpm and a bias of -0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available.
Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J
2016-01-01
Abstract Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of −4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and −5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of −5.6 to 5.2 bpm and a bias of −0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available. PMID:27027672
Paratz, Elizabeth D; Zhao, Jessie; Sherwen, Amanda K; Scarlato, Rose-Marie; MacIsaac, Andrew I
2017-07-01
Methamphetamine use is escalating in Australia and New Zealand, with increasing emergency department attendance and mortality. Cardiac complications play a large role in methamphetamine-related mortality, and it would be informative to assess the frequency of abnormal electrocardiograms (ECGs) amongst methamphetamine users. To determine the frequency and severity of ECG abnormalities amongst methamphetamine users compared to a control group. We conducted a retrospective cohort analysis on 212 patients admitted to a tertiary hospital (106 patients with methamphetamine use, 106 age and gender-matched control patients). Electrocardiograms were analysed according to American College of Cardiology guidelines. Mean age was 33.4 years, with 73.6% male gender, with no significant differences between groups in smoking status, ECG indication, or coronary angiography rates. Methamphetamine users were more likely to have psychiatric admissions (22.6% vs 1.9%, p<0.0001). Overall, ECG abnormalities were significantly more common (71.7% vs 32.1%, p<0.0001) in methamphetamine users, particularly tachyarrhythmias (38.7% vs 26.4%, p<0.0001), right axis deviation (7.5% vs 0.0%, p=0.004), left ventricular hypertrophy (26.4% vs 4.7%, p<0.0001), P pulmonale pattern (7.5% vs 0.9%, p=0.017), inferior Q waves (10.4% vs 0.0%, p=0.001), lateral T wave inversion (3.8% vs 0.0%, p=0.043), and longer QTc interval (436.41±31.61ms vs 407.28±24.38ms, p<0.0001). Transthoracic echocardiogram (n=24) demonstrated left ventricular dysfunction (38%), thrombus (8%), valvular lesions (17%), infective endocarditis (17%), and pulmonary hypertension (13%). Electrocardiograms were only moderately sensitive at predicting abnormal TTE. Electrocardiographic abnormalities are more common in methamphetamine users than age and gender-matched controls. Due to the high frequency of abnormalities, ECGs should be performed in all methamphetamine users who present to hospital. Methamphetamine users with abnormal ECGs should undergo further cardiac investigations. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.
Abedi, Behzad; Abbasi, Ataollah; Goshvarpour, Atefeh
2017-05-01
In the past few decades, several studies have reported the physiological effects of listening to music. The physiological effects of different music types on different people are different. In the present study, we aimed to examine the effects of listening to traditional Persian music on electrocardiogram (ECG) signals in young women. Twenty-two healthy females participated in this study. ECG signals were recorded under two conditions: rest and music. For each ECG signal, 20 morphological and wavelet-based features were selected. Artificial neural network (ANN) and probabilistic neural network (PNN) classifiers were used for the classification of ECG signals during and before listening to music. Collected data were separated into two data sets: train and test. Classification accuracies of 88% and 97% were achieved in train data sets using ANN and PNN, respectively. In addition, the test data set was employed for evaluating the classifiers, and classification rates of 84% and 93% were obtained using ANN and PNN, respectively. The present study investigated the effect of music on ECG signals based on wavelet transform and morphological features. The results obtained here can provide a good understanding on the effects of music on ECG signals to researchers.
Electrocardiograms in Low-Risk Patients Undergoing an Annual Health Examination.
Bhatia, R Sacha; Bouck, Zachary; Ivers, Noah M; Mecredy, Graham; Singh, Jasjit; Pendrith, Ciara; Ko, Dennis T; Martin, Danielle; Wijeysundera, Harindra C; Tu, Jack V; Wilson, Lynn; Wintemute, Kimberly; Dorian, Paul; Tepper, Joshua; Austin, Peter C; Glazier, Richard H; Levinson, Wendy
2017-09-01
Clinical guidelines advise against routine electrocardiograms (ECG) in low-risk, asymptomatic patients, but the frequency and impact of such ECGs are unknown. To assess the frequency of ECGs following an annual health examination (AHE) with a primary care physician among patients with no known cardiac conditions or risk factors, to explore factors predictive of receiving an ECG in this clinical scenario, and to compare downstream cardiac testing and clinical outcomes in low-risk patients who did and did not receive an ECG after their AHE. A population-based retrospective cohort study using administrative health care databases from Ontario, Canada, between 2010/2011 and 2014/2015 to identify low-risk primary care patients and to assess the subsequent outcomes of interest in this time frame. All patients 18 years or older who had no prior cardiac medical history or risk factors who received an AHE. Receipt of an ECG within 30 days of an AHE. Primary outcome was receipt of downstream cardiac testing or consultation with a cardiologist. Secondary outcomes were death, hospitalization, and revascularization at 12 months. A total of 3 629 859 adult patients had at least 1 AHE between fiscal years 2010/2011 and 2014/2015. Of these patients, 21.5% had an ECG within 30 days after an AHE. The proportion of patients receiving an ECG after an AHE varied from 1.8% to 76.1% among 679 primary care practices (coefficient of quartile dispersion [CQD], 0.50) and from 1.1% to 94.9% among 8036 primary care physicians (CQD, 0.54). Patients who had an ECG were significantly more likely to receive additional cardiac tests, visits, or procedures than those who did not (odds ratio [OR], 5.14; 95% CI, 5.07-5.21; P < .001). The rates of death (0.19% vs 0.16%), cardiac-related hospitalizations (0.46% vs 0.12%), and coronary revascularizations (0.20% vs 0.04%) were low in both the ECG and non-ECG cohorts. Despite recommendations to the contrary, ECG testing after an AHE is relatively common, with significant variation among primary care physicians. Routine ECG testing seems to increase risk for a subsequent cardiology testing and consultation cascade, even though the overall cardiac event rate in both groups was very low.
One-Dimensional Signal Extraction Of Paper-Written ECG Image And Its Archiving
NASA Astrophysics Data System (ADS)
Zhang, Zhi-ni; Zhang, Hong; Zhuang, Tian-ge
1987-10-01
A method for converting paper-written electrocardiograms to one dimensional (1-D) signals for archival storage on floppy disk is presented here. Appropriate image processing techniques were employed to remove the back-ground noise inherent to ECG recorder charts and to reconstruct the ECG waveform. The entire process consists of (1) digitization of paper-written ECGs with an image processing system via a TV camera; (2) image preprocessing, including histogram filtering and binary image generation; (3) ECG feature extraction and ECG wave tracing, and (4) transmission of the processed ECG data to IBM-PC compatible floppy disks for storage and retrieval. The algorithms employed here may also be used in the recognition of paper-written EEG or EMG and may be useful in robotic vision.
Cai, Zhipeng; Luo, Kan; Liu, Chengyu; Li, Jianqing
2017-08-09
A smart electrocardiogram (ECG) garment system was designed for continuous, non-invasive and comfortable ECG monitoring, which mainly consists of four components: Conductive textile electrode, garment, flexible printed circuit board (FPCB)-based ECG processing module and android application program. Conductive textile electrode and FPCB-based ECG processing module (6.8 g, 55 mm × 53 mm × 5 mm) are identified as two key techniques to improve the system's comfort and flexibility. Preliminary experimental results verified that the textile electrodes with circle shape, 40 mm size in diameter, and 5 mm thickness sponge are best suited for the long-term ECG monitoring application. The tests on the whole system confirmed that the designed smart garment can obtain long-term ECG recordings with high signal quality.
A miniature on-chip multi-functional ECG signal processor with 30 µW ultra-low power consumption.
Liu, Xin; Zheng, Yuan Jin; Phyu, Myint Wai; Zhao, Bin; Je, Minkyu; Yuan, Xiao Jun
2010-01-01
In this paper, a miniature low-power Electrocardiogram (ECG) signal processing application specific integrated circuit (ASIC) chip is proposed. This chip provides multiple critical functions for ECG analysis using a systematic wavelet transform algorithm and a novel SRAM-based ASIC architecture, while achieves low cost and high performance. Using 0.18 µm CMOS technology and 1 V power supply, this ASIC chip consumes only 29 µW and occupies an area of 3 mm(2). This on-chip ECG processor is highly suitable for reliable real-time cardiac status monitoring applications.
Bond, R R; Kligfield, P D; Zhu, T; Finlay, D D; Drew, B; Guldenring, D; Breen, C; Clifford, G D; Wagner, G S
2015-01-01
The 12-lead electrocardiogram (ECG) is a complex set of cardiac signals that require a high degree of skill and clinical knowledge to interpret. Therefore, it is imperative to record and understand how expert readers interpret the 12-lead ECG. This short paper showcases how eye tracking technology and audio data can be fused together and visualised to gain insight into the interpretation techniques employed by an eminent ECG champion, namely Dr Rory Childers. Copyright © 2015 Elsevier Inc. All rights reserved.
Extrasystoles: side effect of kangaroo care?
Kluthe, Christof; Wauer, Roland R; Rüdiger, Mario
2004-09-01
To present an unpublished reason for an arrhythmic electrocardiogram (ECG) recording during kangaroo care in a preterm infant. Case report. Preterm infant. A preterm infant exhibited cardiac arrhythmia on the ECG monitor during kangaroo care, leading to interruption of kangarooing. Arrhythmia disappeared after placing the baby back into the incubator. The most likely reasons for arrhythmia were excluded. However, arrhythmia reappeared upon continuation of kangaroo care. ECG monitoring revealed the reason for the monitoring error. ECG monitoring during kangaroo care should cause error because of superimposed electric activity from the parent. Oxygen saturation represents a more reliable method of monitoring during kangaroo care.
Surface 12 lead electrocardiogram recordings using smart phone technology.
Baquero, Giselle A; Banchs, Javier E; Ahmed, Shameer; Naccarelli, Gerald V; Luck, Jerry C
2015-01-01
AliveCor ECG is an FDA approved ambulatory cardiac rhythm monitor that records a single channel (lead I) ECG rhythm strip using an iPhone. In the past few years, the use of smartphones and tablets with health related applications has significantly proliferated. In this initial feasibility trial, we attempted to reproduce the 12 lead ECG using the bipolar arrangement of the AliveCor monitor coupled to smart phone technology. We used the AliveCor heart monitor coupled with an iPhone cellular phone and the AliveECG application (APP) in 5 individuals. In our 5 individuals, recordings from both a standard 12 lead ECG and the AliveCor generated 12 lead ECG had the same interpretation. This study demonstrates the feasibility of creating a 12 lead ECG with a smart phone. The validity of the recordings would seem to suggest that this technology could become an important useful tool for clinical use. This new hand held smart phone 12 lead ECG recorder needs further development and validation. Copyright © 2015 Elsevier Inc. All rights reserved.
Steganography in arrhythmic electrocardiogram signal.
Edward Jero, S; Ramu, Palaniappan; Ramakrishnan, S
2015-08-01
Security and privacy of patient data is a vital requirement during exchange/storage of medical information over communication network. Steganography method hides patient data into a cover signal to prevent unauthenticated accesses during data transfer. This study evaluates the performance of ECG steganography to ensure secured transmission of patient data where an abnormal ECG signal is used as cover signal. The novelty of this work is to hide patient data into two dimensional matrix of an abnormal ECG signal using Discrete Wavelet Transform and Singular Value Decomposition based steganography method. A 2D ECG is constructed according to Tompkins QRS detection algorithm. The missed R peaks are computed using RR interval during 2D conversion. The abnormal ECG signals are obtained from the MIT-BIH arrhythmia database. Metrics such as Peak Signal to Noise Ratio, Percentage Residual Difference, Kullback-Leibler distance and Bit Error Rate are used to evaluate the performance of the proposed approach.
A Primary Study of Indirect ECG Monitor Embedded in a Bed for Home Health Care
NASA Astrophysics Data System (ADS)
Ueno, Akinori; Shiogai, Yuuki; Ishiyama, Yoji
A system for monitoring electrocardiogram (ECG) through clothes inserted between the measuring electrodes and the body surface of a subject when lying on a mattress has been proposed. The principle of the system is based on capacitive coupling involving the electrode, the clothes, and the skin. Validation of the system revealed the following: (1) In spite of the gain attenuation in the pass band of the system, distortion of the detected signal was subtle even when clothes thicker than 1mm were inserted, (2) The system was able to yield a stable ECG from a subject particularly during sound sleep, (3) The system succeeded in detecting ECG after changing the posture into any of supine, right lateral, or left lateral positions by adopting a newly devised electrode configuration. Therefore, the proposed system appears promising for application to bedding as a non-invasive and awareness-free system for ECG monitoring during sleep.
ECG Signal Analysis and Arrhythmia Detection using Wavelet Transform
NASA Astrophysics Data System (ADS)
Kaur, Inderbir; Rajni, Rajni; Marwaha, Anupma
2016-12-01
Electrocardiogram (ECG) is used to record the electrical activity of the heart. The ECG signal being non-stationary in nature, makes the analysis and interpretation of the signal very difficult. Hence accurate analysis of ECG signal with a powerful tool like discrete wavelet transform (DWT) becomes imperative. In this paper, ECG signal is denoised to remove the artifacts and analyzed using Wavelet Transform to detect the QRS complex and arrhythmia. This work is implemented in MATLAB software for MIT/BIH Arrhythmia database and yields the sensitivity of 99.85 %, positive predictivity of 99.92 % and detection error rate of 0.221 % with wavelet transform. It is also inferred that DWT outperforms principle component analysis technique in detection of ECG signal.
[Electrocardiographic interpretation in athletes : 2017 recommendations for non-cardiologists].
Meyer, Philippe; Gabus, Vincent
2017-07-12
A resting electrocardiogram (ECG) is recommended for screening of sudden cardiac death in young athletes. However, ECG interpretation in athletes requires an adequate training because normal physiological training adaptations in athletes can sometimes be hardly distinguished from abnormal findings suggestive of underlying pathology. In 2017, a consensus of international experts established new recommendations for a clear and accurate interpretation of ECGs in athletes. This article aims to guide non-cardiologists according to these new data, allowing a better triage of anomalies requiring further investigations.
A remote access ecg monitoring system - biomed 2009.
Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Iwamoto, Junichi; Hahn, Allen W; Caldwell, W Morton
2009-01-01
We have developed a remotely accessible telemedicine system for monitoring a patient's electrocardiogram (ECG). The system consists of an ECG recorder mounted on chest electrodes and a physician's laptop personal computer. This ECG recorder is designed with a variable gain instrumentation amplifier; a low power 8-bit single-chip microcomputer; two 128KB EEPROMs and 2.4 GHz low transmit power mobile telephone. When the physician wants to monitor the patient's ECG, he/she calls directly from the laptop PC to the ECG recorder's phone and the recorder sends the ECG to the computer. The electrode-mounted recorder continuously samples the ECG. Additionally, when the patient feels a heart discomfort, he/she pushes a data transmission switch on the recorder and the recorder sends the recorded ECG waveforms of the two prior minutes, and for two minutes after the switch is pressed. The physician can display and monitor the data on the computer's liquid crystal display.
Zhu, Bohui; Ding, Yongsheng; Hao, Kuangrong
2013-01-01
This paper presents a novel maximum margin clustering method with immune evolution (IEMMC) for automatic diagnosis of electrocardiogram (ECG) arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias. PMID:23690875
Urtnasan, Erdenebayar; Park, Jong-Uk; Joo, Eun-Yeon; Lee, Kyoung-Joung
2018-04-23
In this study, we propose a method for the automated detection of obstructive sleep apnea (OSA) from a single-lead electrocardiogram (ECG) using a convolutional neural network (CNN). A CNN model was designed with six optimized convolution layers including activation, pooling, and dropout layers. One-dimensional (1D) convolution, rectified linear units (ReLU), and max pooling were applied to the convolution, activation, and pooling layers, respectively. For training and evaluation of the CNN model, a single-lead ECG dataset was collected from 82 subjects with OSA and was divided into training (including data from 63 patients with 34,281 events) and testing (including data from 19 patients with 8571 events) datasets. Using this CNN model, a precision of 0.99%, a recall of 0.99%, and an F 1 -score of 0.99% were attained with the training dataset; these values were all 0.96% when the CNN was applied to the testing dataset. These results show that the proposed CNN model can be used to detect OSA accurately on the basis of a single-lead ECG. Ultimately, this CNN model may be used as a screening tool for those suspected to suffer from OSA.
PDF-ECG in clinical practice: A model for long-term preservation of digital 12-lead ECG data.
Sassi, Roberto; Bond, Raymond R; Cairns, Andrew; Finlay, Dewar D; Guldenring, Daniel; Libretti, Guido; Isola, Lamberto; Vaglio, Martino; Poeta, Roberto; Campana, Marco; Cuccia, Claudio; Badilini, Fabio
In clinical practice, data archiving of resting 12-lead electrocardiograms (ECGs) is mainly achieved by storing a PDF report in the hospital electronic health record (EHR). When available, digital ECG source data (raw samples) are only retained within the ECG management system. The widespread availability of the ECG source data would undoubtedly permit successive analysis and facilitate longitudinal studies, with both scientific and diagnostic benefits. PDF-ECG is a hybrid archival format which allows to store in the same file both the standard graphical report of an ECG together with its source ECG data (waveforms). Using PDF-ECG as a model to address the challenge of ECG data portability, long-term archiving and documentation, a real-world proof-of-concept test was conducted in a northern Italy hospital. A set of volunteers undertook a basic ECG using routine hospital equipment and the source data captured. Using dedicated web services, PDF-ECG documents were then generated and seamlessly uploaded in the hospital EHR, replacing the standard PDF reports automatically generated at the time of acquisition. Finally, the PDF-ECG files could be successfully retrieved and re-analyzed. Adding PDF-ECG to an existing EHR had a minimal impact on the hospital's workflow, while preserving the ECG digital data. Copyright © 2017 Elsevier Inc. All rights reserved.
Individual identification via electrocardiogram analysis.
Fratini, Antonio; Sansone, Mario; Bifulco, Paolo; Cesarelli, Mario
2015-08-14
During last decade the use of ECG recordings in biometric recognition studies has increased. ECG characteristics made it suitable for subject identification: it is unique, present in all living individuals, and hard to forge. However, in spite of the great number of approaches found in literature, no agreement exists on the most appropriate methodology. This study aimed at providing a survey of the techniques used so far in ECG-based human identification. Specifically, a pattern recognition perspective is here proposed providing a unifying framework to appreciate previous studies and, hopefully, guide future research. We searched for papers on the subject from the earliest available date using relevant electronic databases (Medline, IEEEXplore, Scopus, and Web of Knowledge). The following terms were used in different combinations: electrocardiogram, ECG, human identification, biometric, authentication and individual variability. The electronic sources were last searched on 1st March 2015. In our selection we included published research on peer-reviewed journals, books chapters and conferences proceedings. The search was performed for English language documents. 100 pertinent papers were found. Number of subjects involved in the journal studies ranges from 10 to 502, age from 16 to 86, male and female subjects are generally present. Number of analysed leads varies as well as the recording conditions. Identification performance differs widely as well as verification rate. Many studies refer to publicly available databases (Physionet ECG databases repository) while others rely on proprietary recordings making difficult them to compare. As a measure of overall accuracy we computed a weighted average of the identification rate and equal error rate in authentication scenarios. Identification rate resulted equal to 94.95 % while the equal error rate equal to 0.92 %. Biometric recognition is a mature field of research. Nevertheless, the use of physiological signals features, such as the ECG traits, needs further improvements. ECG features have the potential to be used in daily activities such as access control and patient handling as well as in wearable electronics applications. However, some barriers still limit its growth. Further analysis should be addressed on the use of single lead recordings and the study of features which are not dependent on the recording sites (e.g. fingers, hand palms). Moreover, it is expected that new techniques will be developed using fiducials and non-fiducial based features in order to catch the best of both approaches. ECG recognition in pathological subjects is also worth of additional investigations.
... CJD: Electroencephalogram (EEG) measures the brain's patterns of electrical activity similar to the way an electrocardiogram (ECG) measures the heart's electrical activity. Brain magnetic resonance imaging (MRI) can detect ...
Hupin, David; Edouard, Pascal; Oriol, Mathieu; Laukkanen, Jari; Abraham, Pierre; Doutreleau, Stéphane; Guy, Jean-Michel; Carré, François; Barthélémy, Jean-Claude; Roche, Frédéric; Chatard, Jean-Claude
2018-04-15
The importance of exercise electrocardiogram (ECG) has been controversial in the prevention of cardiac events among sportsmen. The aim of this study was to determine the frequency of silent myocardial ischemia (SMI) from an exercise ECG and its relationship with induced coronary angiographic assessment and potentially preventable cardiac events. This prospective cohort study included leisure time asymptomatic sportsmen over 35years old, referred from 2011 to 2014 in the Sports Medicine Unit of the University Hospital of Saint-Etienne. Of the cohort of 1500 sportsmen (1205 men; mean age 50.7±9.4years; physical activity level 32.8±26.8MET-h/week), 951 (63%) had at least one cardiovascular disease (CVD) risk factor. Family history, medical examination and standard resting 12-lead were collected. A total of 163 exercise ECGs (10.9%) were defined as positive, most of them due to SMI (n=129, 8.6%). SMI was an indication for coronary angiography in 23 cases, leading to 17 documented SMIs (1.1%), including 11 significant stenoses requiring revascularization. In multivariate logistic regression analysis, a high risk of CVD (OR=2.65 [CI 95%: 1.33-5.27], p=0.005) and an age >50years (OR=2.71 [CI 95%: 1.65-4.44], p<0.0001) were independently associated with confirmed SMI. The association of positive exercise ECG with significant coronary stenosis was stronger among sportsmen with CVD risk factors and older than 50years. Screening by exercise ECG can lower the risk of cardiac events in middle-aged and older sportsmen. One hundred tests would be enough to detect one silent myocardial ischemia at risk for cardiac event. Copyright © 2017 Elsevier B.V. All rights reserved.
O'Neal, Wesley T; Lee, Kristine E; Soliman, Elsayed Z; Klein, Ronald; Klein, Barbara E K
2017-03-01
To determine the incidence and determinants of developing abnormalities on the 12-lead electrocardiogram (ECG) in persons with type 1 diabetes. We evaluated the distribution of ECG abnormalities and risk factors for developing new abnormalities in 266 (mean age = 44 years ± 9.0; 50 % female) people with type 1 diabetes from the Wisconsin Epidemiologic Study of Diabetic Retinopathy. This analysis included participants with complete ECG data from study visit 5 (2000-2001) and follow-up ECGs from study visit 7 (2012-2014). ECG abnormalities were classified as major and minor according to Minnesota Code Classification. At baseline, 94 (35 %) participants had at least one ECG abnormality, including 13 major ECG abnormalities. At follow-up, 117 (44 %) participants developed at least one new ECG abnormality, including 35 new major ECG abnormalities. In a multivariable logistic regression model, older age (per 5-year increase: OR = 1.31, 95 % CI = 1.08, 1.60) was associated with the development of at least one new ECG abnormality, while serum HDL cholesterol (per 10-unit increase: OR = 0.98, 95 % CI = 0.96, 1.00) was protective against developing new ECG abnormalities. The development of new ECG abnormalities is common in type 1 diabetes. Older age and HDL cholesterol are independent risk factors for developing new ECG abnormalities. Further research is needed to determine whether routine ECG screening is indicated in people with type 1 diabetes to identify those with underlying subclinical coronary heart disease.
Utility of the exercise electrocardiogram testing in sudden cardiac death risk stratification.
Refaat, Marwan M; Hotait, Mostafa; Tseng, Zian H
2014-07-01
Sudden cardiac death (SCD) remains a major public health problem. Current established criteria identifying those at risk of sudden arrhythmic death, and likely to benefit from implantable cardioverter defibrillators (ICDs), are neither sensitive nor specific. Exercise electrocardiogram (ECG) testing was traditionally used for information concerning patients' symptoms, exercise capacity, cardiovascular function, myocardial ischemia detection, and hemodynamic responses during activity in patients with hypertrophic cardiomyopathy. We conducted a systematic review of MEDLINE on the utility of exercise ECG testing in SCD risk stratification. Exercise testing can unmask suspected primary electrical diseases in certain patients (catecholaminergic polymorphic ventricular tachycardia or concealed long QT syndrome) and can be effectively utilized to risk stratify patients at an increased (such as early repolarization syndrome and Brugada syndrome) or decreased risk of SCD, such as the loss of preexcitation on exercise testing in asymptomatic Wolff-Parkinson-White syndrome. Exercise ECG testing helps in SCD risk stratification in patients with and without arrhythmogenic hereditary syndromes. © 2014 Wiley Periodicals, Inc.
Mobile messaging services-based personal electrocardiogram monitoring system.
Tahat, Ashraf A
2009-01-01
A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.
Mobile Messaging Services-Based Personal Electrocardiogram Monitoring System
Tahat, Ashraf A.
2009-01-01
A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services. PMID:19707531
Human Age Recognition by Electrocardiogram Signal Based on Artificial Neural Network
NASA Astrophysics Data System (ADS)
Dasgupta, Hirak
2016-12-01
The objective of this work is to make a neural network function approximation model to detect human age from the electrocardiogram (ECG) signal. The input vectors of the neural network are the Katz fractal dimension of the ECG signal, frequencies in the QRS complex, male or female (represented by numeric constant) and the average of successive R-R peak distance of a particular ECG signal. The QRS complex has been detected by short time Fourier transform algorithm. The successive R peak has been detected by, first cutting the signal into periods by auto-correlation method and then finding the absolute of the highest point in each period. The neural network used in this problem consists of two layers, with Sigmoid neuron in the input and linear neuron in the output layer. The result shows the mean of errors as -0.49, 1.03, 0.79 years and the standard deviation of errors as 1.81, 1.77, 2.70 years during training, cross validation and testing with unknown data sets, respectively.
Weaver, James C; Rees, David; Prasan, Ananth M; Ramsay, David D; Binnekamp, Maurits F; McCrohon, Jane A
2011-01-01
Grade 3 ischemia during ST elevation myocardial infarction (STEMI) is defined as ST elevation with distortion of the terminal portion of the QRS on electrocardiogram (ECG). The aim of this study was to evaluate the effect of ischemic grade on cardiac magnetic resonance (CMR) imaging infarct characteristics such as infarct size, microvascular obstruction (MVO), intramyocardial hemorrhage (IMH), and myocardial salvage. Patients with STEMI treated with primary percutaneous coronary intervention had a 12-lead ECG on presentation for analysis of ischemic grade. Gadolinium-enhanced CMR imaging was performed within 7 days to assess infarct size, MVO, IMH, and myocardial salvage. Of the 37 patients enrolled in the study, grade 3 ischemia was present in 32%. Those with grade 3 ischemia had higher peak troponin I levels (P = .013), more MVO (P < .001), more IMH (P < .001), larger infarct size (P = .025), and less myocardial salvage (P = .012). Regression analysis found that grade 3 ischemia, infarct size, and peak troponin I level were significantly associated with MVO and IMH. Grade 3 ischemia on the admission ECG during STEMI is closely associated with the development of severe microvascular damage on CMR imaging. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.
Features of electrocardiogram in patients with stenosis of the proximal right coronary artery
Koh, Moo Seong; Lee, Jae Hoon; Jeong, Jin Woo; Chung, Jun Young
2017-01-01
Background/Aims Prediction of lesions of the proximal right coronary artery (pRCA) through electrocardiogram (ECG) is very important because pRCA occlusion has many complications and a high mortality rate, which has frequently been related with right ventricular infarction. The purpose of this study was to devise a screening tool that takes into account multiple leads from a 12-lead ECG to predict the pRCA lesion. Methods A hundred and fifty-eight patients who were diagnosed as acute coronary syndrome and had a pure lesion of RCA or left circumf lex artery (LCX) by ECGs and angiographic findings were enrolled retrospectively. Forty-eight patients with a pure pRCA occlusion were compared to a control group of 110 patients who were diagnosed as having either a pure mid to distal RCA lesion (57 patients) or a pure LCX lesion (53 patients). Results ECGs of patients in the pRCA group showed more prominent ST depression in lead I (p = 0.001) and ST elevation in V1 (p = 0.002) than in the control group. The combination of ST depression (≤ 0 mm) in I and ST elevation (> 0.5 mm) in V1 was the best diagnostic tool (area under the curve, 0.84). Conclusions ST changes in leads V1 and I allow more accurate prediction of pRCA occlusion than other criteria, such as the difference between ST elevation of leads II and III or vector direction and amplitude. These variables could help to screen for right ventricular infarction before performing reverse ECG and predicting prognosis. PMID:28190326
Features of electrocardiogram in patients with stenosis of the proximal right coronary artery.
Koh, Moo Seong; Lee, Jae Hoon; Jeong, Jin Woo; Chung, Jun Young
2017-03-01
Prediction of lesions of the proximal right coronary artery (pRCA) through electrocardiogram (ECG) is very important because pRCA occlusion has many complications and a high mortality rate, which has frequently been related with right ventricular infarction. The purpose of this study was to devise a screening tool that takes into account multiple leads from a 12-lead ECG to predict the pRCA lesion. A hundred and fifty-eight patients who were diagnosed as acute coronary syndrome and had a pure lesion of RCA or left circumf lex artery (LCX) by ECGs and angiographic findings were enrolled retrospectively. Forty-eight patients with a pure pRCA occlusion were compared to a control group of 110 patients who were diagnosed as having either a pure mid to distal RCA lesion (57 patients) or a pure LCX lesion (53 patients). ECGs of patients in the pRCA group showed more prominent ST depression in lead I ( p = 0.001) and ST elevation in V1 ( p = 0.002) than in the control group. The combination of ST depression (≤ 0 mm) in I and ST elevation (> 0.5 mm) in V1 was the best diagnostic tool (area under the curve, 0.84). ST changes in leads V1 and I allow more accurate prediction of pRCA occlusion than other criteria, such as the difference between ST elevation of leads II and III or vector direction and amplitude. These variables could help to screen for right ventricular infarction before performing reverse ECG and predicting prognosis.
Jayroe, Jason B; Spodick, David H; Nikus, Kjell; Madias, John; Fiol, Miguel; De Luna, Antoni Bayés; Goldwasser, Diego; Clemmensen, Peter; Fu, Yuling; Gorgels, Anton P; Sclarovsky, Samuel; Kligfield, Paul D; Wagner, Galen S; Maynard, Charles; Birnbaum, Yochai
2009-02-01
Guidelines recommend that patients with suggestive symptoms of myocardial ischemia and ST-segment elevation (STE) in > or =2 adjacent electrocardiographic leads should receive immediate reperfusion therapy. Novel strategies aimed to reduce door-to-balloon time, such as prehospital wireless electrocardiographic transmission, may be dependent on the interpretation accuracy of the electrocardiogram (ECG) readers. We assessed the ability of experienced electrocardiographers to differentiate among STE, acute STE myocardial infarction (STEMI), and nonischemic STE (NISTE). A total of 116 consecutive ECGs showing STE were studied. Fifteen experienced cardiologists were asked to decide, based on the ECG and assuming that the patient had compatible symptoms, whether they would send each patient for primary percutaneous coronary intervention (PPCI). If NISTE was chosen, the reader selected 1 or more 12 possible options to explain the choice. Of 116 patients, only 8 had STEMI. The percentage of ECGs for which PPCI was recommended for the patient by the individual readers varied widely (7.8% to 33%). There was no significant difference between the North American and Other Countries readers (p = 0.13). The sensitivity and specificity of the individual readers ranged from 50% to 100% (average 75%) and 73% to 97% (average 85%), respectively. There were broad inconsistencies among the readers in the chosen reasons used to classify NISTE. In conclusion, we found wide variations among experienced electrocardiographers in reading ECGs with STE and differentiating STEMI with need for PPCI from NISTE. There is a need to revise our current electrocardiographic criteria for differentiating STEMI from NISTE.
Heo, Jin-Chul; Kim, Beomjoon; Kim, Yoon-Nyun; Kim, Dae-Kwang; Lee, Jong-Ha
2017-12-14
Prolonged monitoring by cardiac electrocardiogram (ECG) sensors is useful for patients with emergency heart conditions. However, implant monitoring systems are limited by lack of tissue biocompatibility. Here, we developed an implantable ECG sensor for real-time monitoring of ventricular fibrillation and evaluated its biocompatibility using an animal model. The implantable sensor comprised transplant sensors with two electrodes, a wireless power transmission system, and a monitoring system. The sensor was inserted into the subcutaneous tissue of the abdominal area and operated for 1 h/day for 5 days using a wireless power system. Importantly, the sensor was encapsulated by subcutaneous tissue and induced angiogenesis, inflammation, and phagocytosis. In addition, we observed that the levels of inflammation-related markers increased with wireless-powered transmission via the ECG sensor; in particular, levels of the Th-1 cytokine interleukin-12 were significantly increased. The results showed that induced tissue damage was associated with the use of wireless-powered sensors. We also investigated research strategies for the prevention of adverse effects caused by lack of tissue biocompatibility of a wireless-powered ECG monitoring system and provided information on the clinical applications of inflammatory reactions in implant treatment using the wireless-powered transmission system.
Heo, Jin-Chul; Kim, Beomjoon; Kim, Yoon-Nyun; Kim, Dae-Kwang; Lee, Jong-Ha
2017-01-01
Prolonged monitoring by cardiac electrocardiogram (ECG) sensors is useful for patients with emergency heart conditions. However, implant monitoring systems are limited by lack of tissue biocompatibility. Here, we developed an implantable ECG sensor for real-time monitoring of ventricular fibrillation and evaluated its biocompatibility using an animal model. The implantable sensor comprised transplant sensors with two electrodes, a wireless power transmission system, and a monitoring system. The sensor was inserted into the subcutaneous tissue of the abdominal area and operated for 1 h/day for 5 days using a wireless power system. Importantly, the sensor was encapsulated by subcutaneous tissue and induced angiogenesis, inflammation, and phagocytosis. In addition, we observed that the levels of inflammation-related markers increased with wireless-powered transmission via the ECG sensor; in particular, levels of the Th-1 cytokine interleukin-12 were significantly increased. The results showed that induced tissue damage was associated with the use of wireless-powered sensors. We also investigated research strategies for the prevention of adverse effects caused by lack of tissue biocompatibility of a wireless-powered ECG monitoring system and provided information on the clinical applications of inflammatory reactions in implant treatment using the wireless-powered transmission system. PMID:29240666
A web-based approach for electrocardiogram monitoring in the home.
Magrabi, F; Lovell, N H; Celler, B G
1999-05-01
A Web-based electrocardiogram (ECG) monitoring service in which a longitudinal clinical record is used for management of patients, is described. The Web application is used to collect clinical data from the patient's home. A database on the server acts as a central repository where this clinical information is stored. A Web browser provides access to the patient's records and ECG data. We discuss the technologies used to automate the retrieval and storage of clinical data from a patient database, and the recording and reviewing of clinical measurement data. On the client's Web browser, ActiveX controls embedded in the Web pages provide a link between the various components including the Web server, Web page, the specialised client side ECG review and acquisition software, and the local file system. The ActiveX controls also implement FTP functions to retrieve and submit clinical data to and from the server. An intelligent software agent on the server is activated whenever new ECG data is sent from the home. The agent compares historical data with newly acquired data. Using this method, an optimum patient care strategy can be evaluated, a summarised report along with reminders and suggestions for action is sent to the doctor and patient by email.
The 12-lead electrocardiogram and risk of sudden death: current utility and future prospects.
Narayanan, Kumar; Chugh, Sumeet S
2015-10-01
More than 100 years after it was first invented, the 12-lead electrocardiogram (ECG) continues to occupy an important place in the diagnostic armamentarium of the practicing clinician. With the recognition of relatively rare but important clinical entities such as Wolff-Parkinson-White and the long QT syndrome, this clinical tool was firmly established as a test for assessing risk of sudden cardiac death (SCD). However, over the past two decades the role of the ECG in risk prediction for common forms of SCD, for example in patients with coronary artery disease, has been the focus of considerable investigation. Especially in light of the limitations of current risk stratification approaches, there is a renewed focus on this broadly available and relatively inexpensive test. Various abnormalities of depolarization and repolarization on the ECG have been linked to SCD risk; however, more focused work is needed before they can be deployed in the clinical arena. The present review summarizes the current knowledge on various ECG risk markers for prediction of SCD and discusses some future directions in this field. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Wavelet-based watermarking and compression for ECG signals with verification evaluation.
Tseng, Kuo-Kun; He, Xialong; Kung, Woon-Man; Chen, Shuo-Tsung; Liao, Minghong; Huang, Huang-Nan
2014-02-21
In the current open society and with the growth of human rights, people are more and more concerned about the privacy of their information and other important data. This study makes use of electrocardiography (ECG) data in order to protect individual information. An ECG signal can not only be used to analyze disease, but also to provide crucial biometric information for identification and authentication. In this study, we propose a new idea of integrating electrocardiogram watermarking and compression approach, which has never been researched before. ECG watermarking can ensure the confidentiality and reliability of a user's data while reducing the amount of data. In the evaluation, we apply the embedding capacity, bit error rate (BER), signal-to-noise ratio (SNR), compression ratio (CR), and compressed-signal to noise ratio (CNR) methods to assess the proposed algorithm. After comprehensive evaluation the final results show that our algorithm is robust and feasible.
Pogach, Melanie S.; Punjabi, Naresh M.; Thomas, Neil; Thomas, Robert J.
2012-01-01
Study Objectives: Sleep disordered breathing (SDB) is independently associated with insulin resistance, glucose intolerance, and type 2 diabetes mellitus. Experimental sleep fragmentation has been shown to impair insulin sensitivity. Conventional electroencephalogram (EEG)-based sleep-quality measures have been inconsistently associated with indices of glucose metabolism. This analysis explored associations between glucose metabolism and an EEG-independent measure of sleep quality, the sleep spectrogram, which maps coupled oscillations of heart-rate variability and electrocardiogram (ECG)-derived respiration. The method allows improved characterization of the quality of stage 2 non-rapid eye movement (NREM) sleep. Design: Cross-sectional study. Setting: N/A. Participants: Nondiabetic subjects with and without SDB (n = 118) underwent the frequently sampled intravenous glucose tolerance test (FSIVGTT) and a full-montage polysomnogram. The sleep spectrogram was generated from ECG collected during polysomnography. Interventions: N/A. Measurements and Results: Standard polysomnographic stages (stages 1, 2, 3+4, and rapid eye movement [REM]) were not associated with the disposition index (DI) derived from the FSIVGTT. In contrast, spectrographic high-frequency coupling (a marker of stable or “effective” sleep) duration was associated with increased, and very-low-frequency coupling (a marker of wake/REM/transitions) associated with reduced DI. This relationship was noted after adjusting for age, sex, body mass index, slow wave sleep, total sleep time, stage 1, the arousal index, and the apnea-hypopnea index. Conclusions: ECG-derived sleep-spectrogram measures of sleep quality are associated with alterations in glucose-insulin homeostasis. This alternate mode of estimating sleep quality could improve our understanding of sleep and sleep-breathing effects on glucose metabolism. Citation: Pogach MS; Punjabi NM; Thomas N; Thomas RJ. Electrocardiogram-based sleep spectrogram measures of sleep stability and glucose disposal in sleep disordered breathing. SLEEP 2012;35(1):139-148. PMID:22215928
Epidemiological studies demonstrate an association between cardiovascular morbidity, arrhythmias, and exposure to air toxicants such as acrolein. We hypothesized that a single exposure to acrolein would increase arrhythmias and cause changes in the electrocardiogram (ECG) of hype...
Accuracy of remote electrocardiogram interpretation with the use of Google Glass technology.
Jeroudi, Omar M; Christakopoulos, George; Christopoulos, George; Kotsia, Anna; Kypreos, Megan A; Rangan, Bavana V; Banerjee, Subhash; Brilakis, Emmanouil S
2015-02-01
We sought to investigate the accuracy of remote electrocardiogram (ECG) interpretation using Google Glass (Google, Mountain View, California). Google Glass is an optical head mounted display device with growing applications in medicine. We compared interpretation of 10 ECGs with 21 clinically important findings by faculty and fellow cardiologists by (1) viewing the electrocardiographic image at the Google Glass screen; (2) viewing a photograph of the ECG taken using Google Glass and interpreted on a mobile device; (3) viewing the original paper ECG; and (4) viewing a photograph of the ECG taken with a high-resolution camera and interpreted on a mobile device. One point was given for identification of each correct finding. Subjective rating of the user experience was also recorded. Twelve physicians (4 faculty and 8 fellow cardiologists) participated. The average electrocardiographic interpretation score (maximum 21 points) as viewed through the Google Glass, Google Glass photograph on a mobile device, on paper, and high-resolution photograph on a mobile device was 13.5 ± 1.8, 16.1 ± 2.6, 18.3 ± 1.7, and 18.6 ± 1.5, respectively (p = 0.0005 between Google Glass and mobile device, p = 0.0005 between Google Glass and paper, and p = 0.002 between mobile device and paper). Of the 12 physicians, 9 (75%) were dissatisfied with ECGs viewing on the prism display of Google Glass. In conclusion, further improvements are needed before Google Glass can be reliably used for remote electrocardiographic analysis. Published by Elsevier Inc.
Antiperovitch, Pavel; Zareba, Wojciech; Steinberg, Jonathan S; Bacharova, Ljuba; Tereshchenko, Larisa G; Farre, Jeronimo; Nikus, Kjell; Ikeda, Takanori; Baranchuk, Adrian
2018-03-01
Despite its importance in everyday clinical practice, the ability of physicians to interpret electrocardiograms (ECGs) is highly variable. ECG patterns are often misdiagnosed, and electrocardiographic emergencies are frequently missed, leading to adverse patient outcomes. Currently, many medical education programs lack an organized curriculum and competency assessment to ensure trainees master this essential skill. ECG patterns that were previously mentioned in literature were organized into groups from A to D based on their clinical importance and distributed among levels of training. Incremental versions of this organization were circulated among members of the International Society of Electrocardiology and the International Society of Holter and Noninvasive Electrocardiology until complete consensus was reached. We present reasonably attainable ECG interpretation competencies for undergraduate and postgraduate trainees. Previous literature suggests that methods of teaching ECG interpretation are less important and can be selected based on the available resources of each education program and student preference. The evidence clearly favors summative trainee evaluation methods, which would facilitate learning and ensure that appropriate competencies are acquired. Resources should be allocated to ensure that every trainee reaches their training milestones and should ensure that no electrocardiographic emergency (class A condition) is ever missed. We hope that these guidelines will inform medical education programs and encourage them to allocate sufficient resources and develop organized curricula. Assessments must be in place to ensure trainees acquire the level-appropriate ECG interpretation skills that are required for safe clinical practice. © 2017 Society of Hospital Medicine.
Quality Aware Compression of Electrocardiogram Using Principal Component Analysis.
Gupta, Rajarshi
2016-05-01
Electrocardiogram (ECG) compression finds wide application in various patient monitoring purposes. Quality control in ECG compression ensures reconstruction quality and its clinical acceptance for diagnostic decision making. In this paper, a quality aware compression method of single lead ECG is described using principal component analysis (PCA). After pre-processing, beat extraction and PCA decomposition, two independent quality criteria, namely, bit rate control (BRC) or error control (EC) criteria were set to select optimal principal components, eigenvectors and their quantization level to achieve desired bit rate or error measure. The selected principal components and eigenvectors were finally compressed using a modified delta and Huffman encoder. The algorithms were validated with 32 sets of MIT Arrhythmia data and 60 normal and 30 sets of diagnostic ECG data from PTB Diagnostic ECG data ptbdb, all at 1 kHz sampling. For BRC with a CR threshold of 40, an average Compression Ratio (CR), percentage root mean squared difference normalized (PRDN) and maximum absolute error (MAE) of 50.74, 16.22 and 0.243 mV respectively were obtained. For EC with an upper limit of 5 % PRDN and 0.1 mV MAE, the average CR, PRDN and MAE of 9.48, 4.13 and 0.049 mV respectively were obtained. For mitdb data 117, the reconstruction quality could be preserved up to CR of 68.96 by extending the BRC threshold. The proposed method yields better results than recently published works on quality controlled ECG compression.
... by checking it through the skin with a pulse oximeter Complete blood count (CBC) ECG (electrocardiogram) Looking at ... from the groin ( cardiac catheterization ) Transcutaneous oxygen monitor (pulse oximeter) Echo-Doppler
A wearable 12-lead ECG acquisition system with fabric electrodes.
Haoshi Zhang; Lan Tian; Huiyang Lu; Ming Zhou; Haiqing Zou; Peng Fang; Fuan Yao; Guanglin Li
2017-07-01
Continuous electrocardiogram (ECG) monitoring is significant for prevention of heart disease and is becoming an important part of personal and family health care. In most of the existing wearable solutions, conventional metal sensors and corresponding chips are simply integrated into clothes and usually could only collect few leads of ECG signals that could not provide enough information for diagnosis of cardiac diseases such as arrhythmia and myocardial ischemia. In this study, a wearable 12-lead ECG acquisition system with fabric electrodes was developed and could simultaneously process 12 leads of ECG signals. By integrating the fabric electrodes into a T-shirt, the wearable system would provide a comfortable and convenient user interface for ECG recording. For comparison, the proposed fabric electrode and the gelled traditional metal electrodes were used to collect ECG signals on a subject, respectively. The approximate entropy (ApEn) of ECG signals from both types of electrodes were calculated. The experimental results show that the fabric electrodes could achieve similar performance as the gelled metal electrodes. This preliminary work has demonstrated that the developed ECG system with fabric electrodes could be utilized for wearable health management and telemedicine applications.
Cairns, Andrew W; Bond, Raymond R; Finlay, Dewar D; Guldenring, Daniel; Badilini, Fabio; Libretti, Guido; Peace, Aaron J; Leslie, Stephen J
The 12-lead Electrocardiogram (ECG) has been used to detect cardiac abnormalities in the same format for more than 70years. However, due to the complex nature of 12-lead ECG interpretation, there is a significant cognitive workload required from the interpreter. This complexity in ECG interpretation often leads to errors in diagnosis and subsequent treatment. We have previously reported on the development of an ECG interpretation support system designed to augment the human interpretation process. This computerised decision support system has been named 'Interactive Progressive based Interpretation' (IPI). In this study, a decision support algorithm was built into the IPI system to suggest potential diagnoses based on the interpreter's annotations of the 12-lead ECG. We hypothesise semi-automatic interpretation using a digital assistant can be an optimal man-machine model for ECG interpretation. To improve interpretation accuracy and reduce missed co-abnormalities. The Differential Diagnoses Algorithm (DDA) was developed using web technologies where diagnostic ECG criteria are defined in an open storage format, Javascript Object Notation (JSON), which is queried using a rule-based reasoning algorithm to suggest diagnoses. To test our hypothesis, a counterbalanced trial was designed where subjects interpreted ECGs using the conventional approach and using the IPI+DDA approach. A total of 375 interpretations were collected. The IPI+DDA approach was shown to improve diagnostic accuracy by 8.7% (although not statistically significant, p-value=0.1852), the IPI+DDA suggested the correct interpretation more often than the human interpreter in 7/10 cases (varying statistical significance). Human interpretation accuracy increased to 70% when seven suggestions were generated. Although results were not found to be statistically significant, we found; 1) our decision support tool increased the number of correct interpretations, 2) the DDA algorithm suggested the correct interpretation more often than humans, and 3) as many as 7 computerised diagnostic suggestions augmented human decision making in ECG interpretation. Statistical significance may be achieved by expanding sample size. Copyright © 2017 Elsevier Inc. All rights reserved.
Willem Einthoven and the birth of clinical electrocardiography a hundred years ago.
Barold, S Serge
2003-01-01
The first electrocardiogram (ECG) from the intact human heart was recorded with a mercury capillary electrometer by Augustus Waller in May 1887 at St. Mary's Hospital, London. The tracings were poor and exhibited only 2 distorted deflections. Willem Einthoven (1860-1927) who was professor of physiology at the University of Leiden, The Netherlands, began his studies of the ECG with the mercury capillary electrometer, and improved its distortion mathematically so that he was finally able to register a good representation of the ECG before the beginning of the twentieth century. He later further improved ECG recordings with the introduction of a string galvanometer of his design. Einthoven published his first article about the string galvanometer in 1901, followed by a more detailed description in 1903 which included a report of ECGs taken with the new instrument. The year 2002 marks the centennial of Willem Einthoven's first recording of the ECG in a clinically applicable fashion with the string galvanometer. The clinical use of Einthoven's immobile equipment required transtelephonic transmission of the ECG from the physiology laboratory to the clinic at the Academic Hospital about a mile away as documented in the 1906 paper on the "télécardiogramme". This report contained a wealth of ECG patterns and arrhythmias. Einthoven developed a system of electrocardiographic standardization that continues to be used all over the world and introduced the triaxial bipolar system with 3 limb leads and thus established uniformity of the recording process. Einthoven also conceived the famous equilateral triangle with leads I, II, and III at its sides and the calculation of the electrical axis (in the frontal plane) depicted as a single vector with an arrow at the center of the triangle. Einthoven recognized the great potential importance of the ECG as a diagnostic and investigative tool and his achievements made him the founder of modern electrocardiography. He was awarded the Nobel Prize in 1924 (2 years after Waller's death) in physiology and medicine, "for the discovery of the mechanism of the electrocardiogram."
Image-guided optimization of the ECG trace in cardiac MRI.
Barnwell, James D; Klein, J Larry; Stallings, Cliff; Sturm, Amanda; Gillespie, Michael; Fine, Jason; Hyslop, W Brian
2012-03-01
Improper electrocardiogram (ECG) lead placement resulting in suboptimal gating may lead to reduced image quality in cardiac magnetic resonance imaging (CMR). A patientspecific systematic technique for rapid optimization of lead placement may improve CMR image quality. A rapid 3 dimensional image of the thorax was used to guide the realignment of ECG leads relative to the cardiac axis of the patient in forty consecutive adult patients. Using our novel approach and consensus reading of pre- and post-correction ECG traces, seventy-three percent of patients had a qualitative improvement in their ECG tracings, and no patient had a decrease in quality of their ECG tracing following the correction technique. Statistically significant improvement was observed independent of gender, body mass index, and cardiac rhythm. This technique provides an efficient option to improve the quality of the ECG tracing in patients who have a poor quality ECG with standard techniques.
NASA Astrophysics Data System (ADS)
Agung, Mochammad Anugrah; Basari
2017-02-01
Electrocardiogram (ECG) devices measure electrical activity of the heart muscle to determine heart conditions. ECG signal quality is the key factor in determining the diseases of the heart. This paper presents the design of 3-lead acquistion on single channel wireless ECG device developed on AD8232 chip platform using microcontroller. To make the system different from others, monopole antenna 2.4 GHz is used in order to send and receive ECG signal. The results show that the system still can receive ECG signal up to 15 meters by line of sight (LOS) condition. The shape of ECG signals is precisely similar with the expected signal, although some delays occur between two consecutive pulses. For further step, the system will be applied with on-body antenna in order to investigate body to body communication that will give variation in connectivity from the others.
Multiscale permutation entropy analysis of electrocardiogram
NASA Astrophysics Data System (ADS)
Liu, Tiebing; Yao, Wenpo; Wu, Min; Shi, Zhaorong; Wang, Jun; Ning, Xinbao
2017-04-01
To make a comprehensive nonlinear analysis to ECG, multiscale permutation entropy (MPE) was applied to ECG characteristics extraction to make a comprehensive nonlinear analysis of ECG. Three kinds of ECG from PhysioNet database, congestive heart failure (CHF) patients, healthy young and elderly subjects, are applied in this paper. We set embedding dimension to 4 and adjust scale factor from 2 to 100 with a step size of 2, and compare MPE with multiscale entropy (MSE). As increase of scale factor, MPE complexity of the three ECG signals are showing first-decrease and last-increase trends. When scale factor is between 10 and 32, complexities of the three ECG had biggest difference, entropy of the elderly is 0.146 less than the CHF patients and 0.025 larger than the healthy young in average, in line with normal physiological characteristics. Test results showed that MPE can effectively apply in ECG nonlinear analysis, and can effectively distinguish different ECG signals.
Nakamura, Sachiko; Adachi, Hisashi; Enomoto, Mika; Fukami, Ako; Kumagai, Eita; Nohara, Yume; Kono, Shoko; Nakao, Erika; Sakaue, Akiko; Tsuru, Tomoko; Morikawa, Nagisa; Fukumoto, Yoshihiro
2017-10-01
An understanding of the trends in regard to coronary risk factors and electrocardiogram (ECG) findings has an important role in public health. We investigated the trends in coronary risk factors and main ECG findings in 1977, 1989, 1999, and 2009 in the Japanese cohort of the Seven Countries Study, in Tanushimaru, a typical farming town on Kyushu Island. A total of 1397 subjects (231 in 1977, 332 in 1989, 389 in 1999, and 445 in 2009) were enrolled in this study, and all of them were males aged over 65 years. In coronary risk factors, total cholesterol levels, diastolic blood pressure, body mass index, and uric acid significantly increased during these 3 decades. The prevalence of smokers markedly decreased from 56.7% in 1977 to 16.8% in 2009. ECG changes during 3 decades were wider QRS interval, increased prevalence of major abnormality, reduced heart rate, shortened PR interval and corrected QT, and decreased prevalence of left ventricular hypertrophy. Age, smoking habits, major and minor abnormalities in ECG were associated with mortality in 1977-1987. Age, total cholesterol levels (inversely) and corrected QT were associated with mortality in 1989-1999. Age, smoking habits, heart rate, and systolic blood pressure were associated with mortality in 1999-2009. Predictors of mortality have changed with the times. Coronary risk factors such as smoking, increased heart rate, and elevated blood pressure have been recently associated with mortalities in elderly male Japanese general population. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Learning electrocardiogram on YouTube: how useful is it?
Akgun, Taylan; Karabay, Can Yucel; Kocabay, Gonenc; Kalayci, Arzu; Oduncu, Vecih; Guler, Ahmet; Pala, Selcuk; Kirma, Cevat
2014-01-01
YouTube has become a useful resource for knowledge and is widely used by medical students as an e-learning source. The purpose of this study was to assess the videos relating electrocardiogram (ECG) on YouTube. YouTube was searched on May 28, 2013 for the search terms "AF ecg" for atrial fibrillation, "AVNRT" for atrioventricular nodal reentrant tachycardia, "AVRT" for atrioventricular reentrant tachycardia, "AV block or heart block" for atrioventricular block, "LBBB, RBBB" for bundle branch block, "left anterior fascicular block or left posterior fascicular block" for fascicular blocks, "VT ecg" for ventricular tachycardia, "long QT" and "Brugada ecg". Non-English language, unrelated and non-educational videos were excluded. Remaining videos were assessed for usefulness, source and characteristics. Usefulness was assessed with using a checklist developed by the authors. One hundred nineteen videos were included in the analysis. Sources of the videos were as follows: individuals n=70, 58.8%, universities/hospitals n=10, 8.4% and medical organizations n=3, 2.5%, health ads n=10 8.4%, health websites n=26, 21.8%. Fifty-six (47.1%) videos were classified as very useful and 16 (13.4%) videos were misleading. 90% of the videos uploaded by universities/hospitals were grouped as very useful videos, the same ratio was 45% for the individual uploads. There were statistically significant differences in ECG diagnosis among the groups (for very useful, useful and misleading, p<0.001, 0.02 and 0.008, respectively). The ratio of the misleading information in ventricular tachycardia videos was found to be 42.9%. YouTube has a substantial amount of videos on ECG with a wide diversity from useful to misleading content. The lack of quality content relating to ECG on YouTube necessitates that videos should be selected with utmost care. © 2013 Elsevier Inc. All rights reserved.
Acute Myocardial Ischemia: Cellular Mechanisms Underlying ST Segment Elevation
Di Diego, José M.; Antzelevitch, Charles
2014-01-01
The electrocardiogram (ECG) is an essential tool for the diagnosis of acute myocardial ischemia in the emergency department, as well as for that of an evolving acute myocardial infarction (AMI). Changes in the surface ECG in leads whose positive poles face the ischemic region are known to be related to injury currents flowing across the boundaries between the ischemic and the surrounding normal myocardium. Although experimental studies have also shown an endocardium to epicardium differential sensitivity to the effect of acute ischemia, the important contribution of this transmural heterogeneous response to the changes observed in the surface ECG are less appreciated by the clinical cardiologist. This review briefly discusses our current knowledge regarding the electrophysiology of the ischemic myocardium focusing primarily on the electrophysiologic changes underlying the ECG alterations observed at the onset of a transmural AMI. PMID:24742586
ERIC Educational Resources Information Center
van den Berge, Kees; van Gog, Tamara; Mamede, Silvia; Schmidt, Henk G.; van Saase, Jan L. C. M.; Rikers, Remy M. J. P.
2013-01-01
Research has shown that for acquiring problem-solving skills, instruction consisting of studying worked examples is more effective and efficient for novice learners than instruction consisting of problem-solving. This study investigated whether worked examples would also be a useful instructional format for the acquisition of visual perceptual…
Paramedic electrocardiogram and rhythm identification: a convenient training device.
Hale, Peggy; Lowe, Robert; Seamon, Jason P; Jenkins, James J
2011-10-01
A common reason for utilizing local paramedics and the emergency medical services is for the recognition and immediate treatment of chest pain, a complaint that has multiple possible etiologies. While many of those complaining of disease processes responsible for chest pain are benign, some will be life-threatening and will require immediate identification and treatment. The ability of paramedics to not only perform field electrocardiograms (ECGs), but to accurately diagnose various unstable cardiac rhythms has shown significant reduction in time to specific treatments. Increasing the overall accuracy of ECG interpretation by paramedics has the potential to facilitate early and appropriate treatment and decrease patient morbidity and mortality. A convenient training device (flip book) on ambulances and in common areas in the fire station could improve field interpretation of certain cardiac rhythms. This training device consists of illustrated sample ECG tracings and their associated diagnostic criteria. The goal was to enhance the recognition and interpretation of ECGs, and thereby, reduce delays in the initiation of treatment and potential complications associated with misinterpretation.This study was a prospective, observational study using a matched pre-test/post-test design. The study period was from November 2008 to December 2008. A total of 136 paramedics were approached to participate in this study. A pre-test consisting of 15 12-lead ECGs was given to all paramedics who agreed to participate in the study. Once the pre-tests were completed, the flip books were placed in common areas. Approximately one month after the flip books were made available to the paramedics, a post-test was administered.Statistical comparisons were made between the pre- and post-test scores for both the global test and each type of rhythm. Using these data, there were no statistically significant improvements in the global ECG interpretation or on individual rhythm interpretations. A flip book with multiple ECG rhythms and definitions without the benefit of any outside support was not effective in improving paramedic identification of ECG rhythms on a post-test. Suggestions for further research include repeating the study with a larger sample size; utilizing a lecturer to explain how to use the flip book in the most efficient manner; reiterating how to read and interpret ECGs; and answering questions. Comparing test scores of paramedic students, and newly certified paramedics as opposed to veteran paramedics also may indicate that the flip books are more suited for one group over another.
Yang, Kai; Jiang, Xuejun; Cheng, Shuqun; Chen, Chengzhi; Cao, Xianqing; Tu, Baijie
2017-01-24
To evaluate the effects of occupational exposures to coke oven emissions (COEs) and benzo[a]pyrene (B[a]P) on the prevalence of hypertension and abnormal electrocardiogram (ECG) in coke oven workers. We included 880 coke oven workers and 710 oxygen employees in the exposed and control groups, respectively. Blood pressure (BP), ECG, blood lipid levels, and glucose levels of all subjects were measured. COE and B[a]P concentrations at the bottom, side, and top of the oven and control plants were estimated by weighing and high-performance liquid chromatography. The COE concentration at the top and side was higher than that at the bottom (P < 0.05). The levels of B[a]P at the top and side significantly exceeded the limit value. Abnormal BP, ECG, the detection ratio of hypertension and left ventricular high voltage were significantly greater in the exposed group than in the control group (P < 0.05). The logistic regression analysis results revealed that age and B[a]P exposure were risk factors for hypertension in coke oven workers (P < 0.05) and both were risk factors for abnormal ECG (P < 0.05). Moreover, B[a]P exposure, age, and gender were risk factors for impaired fasting glucose in coke oven workers (P < 0.05). B[a]P and COE exposures are risk factors for hypertension and abnormal ECG in coke oven workers.
... help walking when you have a loss of balance during a vertigo attack. Avoid bright lights, TV, ... include: Blood pressure reading Electrocardiogram ( ECG ) Hearing tests Balance testing ( ENG ) Magnetic Resonance Imaging (MRI) Your provider ...
... history of heart disease in the family Normal Results Normal test results include: Heart rate: 60 to ... minute Heart rhythm: Consistent and even What Abnormal Results Mean Abnormal ECG results may be a sign ...
Wang, Duolao; Bakhai, Ameet; Arezina, Radivoj; Täubel, Jörg
2016-11-01
Electrocardiogram (ECG) variability is greatly affected by the ECG recording method. This study aims to compare Holter and standard ECG recording methods in terms of central locations and variations of ECG data. We used the ECG data from a double-blinded, placebo-controlled, randomized clinical trial and used a mixed model approach to assess the agreement between two methods in central locations and variations of eight ECG parameters (Heart Rate, PR, QRS, QT, RR, QTcB, QTcF, and QTcI intervals). A total of 34 heathy male subjects with mean age of 25.7 ± 4.78 years were randomized to receive either active drug or placebo. Digital 12-lead ECG and digital 12-lead Holter ECG recordings were performed to assess ECG variability. There are no significant differences in least square mean between the Holter and the standard method for all ECG parameters. The total variance is consistently higher for the Holter method than the standard method for all ECG parameters except for QRS. The intraclass correlation coefficient (ICC) values for the Holter method are consistently lower than those for the standard method for all ECG parameters except for QRS, in particular, the ICC for QTcF is reduced from 0.86 for the standard method to 0.67 for the Holter method. This study suggests that Holter ECGs recorded in a controlled environment are not significantly different but more variable than those from the standard method. © 2016 Wiley Periodicals, Inc.
Are ECG abnormalities in Noonan syndrome characteristic for the syndrome?
Raaijmakers, R; Noordam, C; Noonan, J A; Croonen, E A; van der Burgt, C J A M; Draaisma, J M T
2008-12-01
Of all patients with Noonan syndrome, 50-90% have one or more congenital heart defects. The most frequent occurring are pulmonary stenosis (PS) and hypertrophic cardiomyopathy. The electrocardiogram (ECG) of a patient with Noonan syndrome often shows a characteristic pattern, with a left axis deviation, abnormal R/S ratio over the left precordium, and an abnormal Q wave. The objective of this study was to determine if these ECG characteristics are an independent feature of the Noonan syndrome or if they are related to the congenital heart defect. A cohort study was performed with 118 patients from two university hospitals in the United States and in The Netherlands. All patients were diagnosed with definite Noonan syndrome and had had an ECG and echocardiography. Sixty-nine patients (58%) had characteristic abnormalities of the ECG. In the patient group without a cardiac defect (n = 21), ten patients had a characteristic ECG abnormality. There was no statistical relationship between the presence of a characteristic ECG abnormality and the presence of a cardiac defect (p = 0.33). Patients with hypertrophic cardiomyopathy had more ECG abnormalities in total (p = 0.05), without correlation with a specific ECG abnormality. We conclude that the ECG features in patients with Noonan syndrome are characteristic for the syndrome and are not related to a specific cardiac defect. An ECG is very useful in the diagnosis of Noonan syndrome; every child with a Noonan phenotype should have an ECG and echocardiogram for evaluation.
Murugappan, Murugappan; Murugappan, Subbulakshmi; Zheng, Bong Siao
2013-01-01
[Purpose] Intelligent emotion assessment systems have been highly successful in a variety of applications, such as e-learning, psychology, and psycho-physiology. This study aimed to assess five different human emotions (happiness, disgust, fear, sadness, and neutral) using heart rate variability (HRV) signals derived from an electrocardiogram (ECG). [Subjects] Twenty healthy university students (10 males and 10 females) with a mean age of 23 years participated in this experiment. [Methods] All five emotions were induced by audio-visual stimuli (video clips). ECG signals were acquired using 3 electrodes and were preprocessed using a Butterworth 3rd order filter to remove noise and baseline wander. The Pan-Tompkins algorithm was used to derive the HRV signals from ECG. Discrete wavelet transform (DWT) was used to extract statistical features from the HRV signals using four wavelet functions: Daubechies6 (db6), Daubechies7 (db7), Symmlet8 (sym8), and Coiflet5 (coif5). The k-nearest neighbor (KNN) and linear discriminant analysis (LDA) were used to map the statistical features into corresponding emotions. [Results] KNN provided the maximum average emotion classification rate compared to LDA for five emotions (sadness − 50.28%; happiness − 79.03%; fear − 77.78%; disgust − 88.69%; and neutral − 78.34%). [Conclusion] The results of this study indicate that HRV may be a reliable indicator of changes in the emotional state of subjects and provides an approach to the development of a real-time emotion assessment system with a higher reliability than other systems. PMID:24259846
Murugappan, Murugappan; Murugappan, Subbulakshmi; Zheng, Bong Siao
2013-07-01
[Purpose] Intelligent emotion assessment systems have been highly successful in a variety of applications, such as e-learning, psychology, and psycho-physiology. This study aimed to assess five different human emotions (happiness, disgust, fear, sadness, and neutral) using heart rate variability (HRV) signals derived from an electrocardiogram (ECG). [Subjects] Twenty healthy university students (10 males and 10 females) with a mean age of 23 years participated in this experiment. [Methods] All five emotions were induced by audio-visual stimuli (video clips). ECG signals were acquired using 3 electrodes and were preprocessed using a Butterworth 3rd order filter to remove noise and baseline wander. The Pan-Tompkins algorithm was used to derive the HRV signals from ECG. Discrete wavelet transform (DWT) was used to extract statistical features from the HRV signals using four wavelet functions: Daubechies6 (db6), Daubechies7 (db7), Symmlet8 (sym8), and Coiflet5 (coif5). The k-nearest neighbor (KNN) and linear discriminant analysis (LDA) were used to map the statistical features into corresponding emotions. [Results] KNN provided the maximum average emotion classification rate compared to LDA for five emotions (sadness - 50.28%; happiness - 79.03%; fear - 77.78%; disgust - 88.69%; and neutral - 78.34%). [Conclusion] The results of this study indicate that HRV may be a reliable indicator of changes in the emotional state of subjects and provides an approach to the development of a real-time emotion assessment system with a higher reliability than other systems.
Cardiology electrocardiogram overreads rarely influence patient care outcome.
Proano, Lawrence; Sucov, Andrew; Woolard, Robert
2014-11-01
The value of electrocardiogram (ECG) overreads of emergency department (ED) tracings have been questioned in the literature. This review was designed to assess the validity of this criticism. In this university teaching hospital ED, following the normal quality assurance protocol, each abnormal ECG is reviewed the following day against the corresponding chart; and if the official reading from cardiology is discordant from the initial clinical one, the patient and/or their physician is contacted. If necessary, the patient is instructed to return to the ED or to their private physician's office. This study is a retrospective review of those ECG overreads for a 21-month period, as well as a summary of those patients who required follow-up care. There were 38,490 patients seen with ECGs performed during the study interval. Of these, 16,011 were discharged and 22,479 were admitted from a total patient volume of 117,407. Of those 16,011 patients discharged, follow-up was deemed necessary in 22 patients whose official readings were discordant from the interpretation of the original clinician. Three patients were lost to follow-up (no phone, no address). Review of the tracings and patient/physician follow-up of the 19 remaining patients resulted in a significant change of therapy in 2 patients (admission). The remainder of the abnormal tracings were deemed, after patient or private physician follow-up, to be not significant or to mandate no change in management. Official cardiology overreads seldom affect the clinical outcome of patient care delivered in the ED setting. Copyright © 2014 Elsevier Inc. All rights reserved.
Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Alastruey, Jordi; Clifton, David A; Beale, Richard; Watkinson, Peter J
2017-05-01
Breathing rate (BR) can be estimated by extracting respiratory signals from the electrocardiogram (ECG) or photoplethysmogram (PPG). The extracted respiratory signals may be influenced by several technical and physiological factors. In this study, our aim was to determine how technical and physiological factors influence the quality of respiratory signals. Using a variety of techniques 15 respiratory signals were extracted from the ECG, and 11 from PPG signals collected from 57 healthy subjects. The quality of each respiratory signal was assessed by calculating its correlation with a reference oral-nasal pressure respiratory signal using Pearson's correlation coefficient. Relevant results informing device design and clinical application were obtained. The results informing device design were: (i) seven out of 11 respiratory signals were of higher quality when extracted from finger PPG compared to ear PPG; (ii) laboratory equipment did not provide higher quality of respiratory signals than a clinical monitor; (iii) the ECG provided higher quality respiratory signals than the PPG; (iv) during downsampling of the ECG and PPG significant reductions in quality were first observed at sampling frequencies of <250 Hz and <16 Hz respectively. The results informing clinical application were: (i) frequency modulation-based respiratory signals were generally of lower quality in elderly subjects compared to young subjects; (ii) the qualities of 23 out of 26 respiratory signals were reduced at elevated BRs; (iii) there were no differences associated with gender. Recommendations based on the results are provided regarding device designs for BR estimation, and clinical applications. The dataset and code used in this study are publicly available.
Application of exercise ECG stress test in the current high cost modern-era healthcare system.
Vaidya, Gaurang Nandkishor
Exercise electrocardiogram (ECG) tests boasts of being more widely available, less resource intensive, lower cost and absence of radiation. In the presence of a normal baseline ECG, an exercise ECG test is able to generate a reliable and reproducible result almost comparable to Technitium-99m sestamibi perfusion imaging. Exercise ECG changes when combined with other clinical parameters obtained during the test has the potential to allow effective redistribution of scarce resources by excluding low risk patients with significant accuracy. As we look towards a future of rising healthcare costs, increased prevalence of cardiovascular disease and the need for proper allocation of limited resources; exercise ECG test offers low cost, vital and reliable disease interpretation. This article highlights the physiology of the exercise ECG test, patient selection, effective interpretation, describe previously reported scores and their clinical application in today's clinical practice. Copyright © 2017. Published by Elsevier B.V.
Left arm/left leg lead reversals at the cable junction box: A cause for an epidemic of errors.
Velagapudi, Poonam; Turagam, Mohit K; Ritter, Sherry; Dohrmann, Mary L
Medical errors, especially due to misinterpretation of electrocardiograms (ECG), are extremely common in patients admitted to the hospital and significantly account for increased morbidity, mortality and health care costs in the United States. Inaccurate performance of an ECG can lead to invalid interpretation and in turn may lead to costly cardiovascular evaluation. We report a retrospective series of 58 sequential cases of ECG limb lead reversals in the ER due to inadvertent interchange in the lead cables at the point where they insert into the cable junction box of one ECG machine. This case series highlights recognition of ECG lead reversal originating in the ECG machine itself. This case series also demonstrates an ongoing need for education regarding standardization of ECG testing and for recognizing technical anomalies to deliver appropriate care for the patient. Copyright © 2016. Published by Elsevier Inc.
Empirical mode decomposition of the ECG signal for noise removal
NASA Astrophysics Data System (ADS)
Khan, Jesmin; Bhuiyan, Sharif; Murphy, Gregory; Alam, Mohammad
2011-04-01
Electrocardiography is a diagnostic procedure for the detection and diagnosis of heart abnormalities. The electrocardiogram (ECG) signal contains important information that is utilized by physicians for the diagnosis and analysis of heart diseases. So good quality ECG signal plays a vital role for the interpretation and identification of pathological, anatomical and physiological aspects of the whole cardiac muscle. However, the ECG signals are corrupted by noise which severely limit the utility of the recorded ECG signal for medical evaluation. The most common noise presents in the ECG signal is the high frequency noise caused by the forces acting on the electrodes. In this paper, we propose a new ECG denoising method based on the empirical mode decomposition (EMD). The proposed method is able to enhance the ECG signal upon removing the noise with minimum signal distortion. Simulation is done on the MIT-BIH database to verify the efficacy of the proposed algorithm. Experiments show that the presented method offers very good results to remove noise from the ECG signal.
Liang, Lijun; Hu, Yao; Liu, Hao; Li, Xiaojiu; Li, Jin; He, Yin
2017-04-01
In order to reduce the mortality rate of cardiovascular disease patients effectively, improve the electrocardiogram (ECG) accuracy of signal acquisition, and reduce the influence of motion artifacts caused by the electrodes in inappropriate location in the clothing for ECG measurement, we in this article present a research on the optimum place of ECG electrodes in male clothing using three-lead monitoring methods. In the 3-lead ECG monitoring clothing for men we selected test points. Comparing the ECG and power spectrum analysis of the acquired ECG signal quality of each group of points, we determined the best location of ECG electrodes in the male monitoring clothing. The electrode motion artifacts caused by improper location had been significantly improved when electrodes were put in the best position of the clothing for men. The position of electrodes is crucial for ECG monitoring clothing. The stability of the acquired ECG signal could be improved significantly when electrodes are put at optimal locations.
Schuur, Jeremiah D; Justice, Amy
2009-01-01
The objective was to calculate agreement between syncope as a reason for visiting (RFV) an emergency department (ED) and as a discharge diagnosis (International Classification of Diseases, Ninth Revision, Clinical Modification [ICD-9]), to determine whether syncope case definition biases reported electrocardiogram (ECG) usage, a national quality measure. The authors analyzed the ED portion of the National Hospital Ambulatory Medical Care Survey (NHAMCS), 1993-2004, for patients age >or=18 years. A visit was defined as being for syncope if it received one of three RFV or ICD-9 codes. Agreement between RFV and ICD-9 codes was calculated, and the percentages of syncope patients (RFV vs. ICD-9) who had an ECG were compared using chi-square and multivariate logistic regression. Raw agreement between syncope as an RFV and as an ICD-9 diagnosis code was 30.1% (95% confidence interval [CI] = 32.6% to 35.5%), representing only moderate agreement beyond chance (kappa = 0.50). ECG utilization was lower among visits defined by RFV (64.1%; 95% CI = 62.0% to 66.3%) than for ICD-9 diagnosis (73.6%; 95% CI = 71.4% to 75.8%). There was no meaningful variation in adjusted ECG use by patient, visit, or hospital characteristics between case definitions. Adjusted ECG use was lower under both case definitions among female patients and discharged patients and increased with age (p < 0.05). Despite only moderate agreement, syncope case definition should not bias reported ECG rate by patient, visit, or hospital characteristics. Among ED patients with syncope, ECG is performed less frequently in women, a potentially important disparity.
Kim, Youn-Jung; Min, Sun-Yang; Lee, Dong Hun; Lee, Byung Kook; Jeung, Kyung Woon; Lee, Hui Jai; Shin, Jonghwan; Ko, Byuk Sung; Ahn, Shin; Nam, Gi-Byoung; Lim, Kyoung Soo; Kim, Won Young
2017-03-13
The authors aimed to evaluate the role of post-resuscitation electrocardiogram (ECG) in patients showing significant ST-segment changes on the initial ECG and to provide useful diagnostic indicators for physicians to determine in which out-of-hospital cardiac arrest (OHCA) patients brain computed tomography (CT) should be performed before emergency coronary angiography. The usefulness of immediate brain CT and ECG for all resuscitated patients with nontraumatic OHCA remains controversial. Between January 2010 and December 2014, 1,088 consecutive adult nontraumatic patients with return of spontaneous circulation who visited the emergency department of 3 tertiary care hospitals were enrolled. After excluding 245 patients with obvious extracardiac causes, 200 patients were finally included. The patients were categorized into 2 groups: those with ST-segment changes with spontaneous subarachnoid hemorrhage (SAH) (n = 50) and those with OHCA of suspected cardiac origin group (n = 150). The combination of 4 ECG characteristics including narrow QRS (<120 ms), atrial fibrillation, prolonged QTc interval (≥460 ms), and ≥4 ST-segment depressions had a 66.0% sensitivity, 80.0% specificity, 52.4% positive predictive value, and 87.6% negative predictive value for predicting SAH. The area under the receiver-operating characteristic curves in the post-resuscitation ECG findings was 0.816 for SAH. SAH was observed in a substantial number of OHCA survivors (25.0%) with significant ST-segment changes on post-resuscitation ECG. Resuscitated patients with narrow QRS complex and any 2 ECG findings of atrial fibrillation, QTc interval prolongation, or ≥4 ST-segment depressions may help identify patients who need brain CT as the next diagnostic work-up. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Rui, Zeng; Lian-Rui, Xiang; Rong-Zheng, Yue; Jing, Zeng; Xue-Hong, Wan; Chuan, Zuo
2017-03-07
Interpreting an electrocardiogram (ECG) is not only one of the most important parts of clinical diagnostics but also one of the most difficult topics to teach and learn. In order to enable medical students to master ECG interpretation skills in a limited teaching period, the flipped teaching method has been recommended by previous research to improve teaching effect on undergraduate ECG learning. A randomized controlled trial for ECG learning was conducted, involving 181 junior-year medical undergraduates using a flipped classroom as an experimental intervention, compared with Lecture-Based Learning (LBL) as a control group. All participants took an examination one week after the intervention by analysing 20 ECGs from actual clinical cases and submitting their ECG reports. A self-administered questionnaire was also used to evaluate the students' attitudes, total learning time, and conditions under each teaching method. The students in the experimental group scored significantly higher than the control group (8.72 ± 1.01 vs 8.03 ± 1.01, t = 4.549, P = 0.000) on ECG interpretation. The vast majority of the students in the flipped classroom group held positive attitudes toward the flipped classroom method and also supported LBL. There was no significant difference (4.07 ± 0.96 vs 4.16 ± 0.89, Z = - 0.948, P = 0.343) between the groups. Prior to class, the students in the flipped class group devoted significantly more time than those in the control group (42.33 ± 22.19 vs 30.55 ± 10.15, t = 4.586, P = 0.000), whereas after class, the time spent by the two groups were not significantly different (56.50 ± 46.80 vs 54.62 ± 31.77, t = 0.317, P = 0.752). Flipped classroom teaching can improve medical students' interest in learning and their self-learning abilities. It is an effective teaching model that needs to be further studied and promoted.
Artifactual ECG changes induced by electrocautery in a patient with coronary artery disease.
Naik, B Naveen; Luthra, Ankur; Dwivedi, Ashish; Jafra, Anudeep
Continuous monitoring of 5-lead electrocardiogram is a basic standard of care (included under standard ASA monitor) in the operating room and electrocautery interference is a common phenomenon. Clinical signs, along with monitored waveforms from other simultaneously monitored parameters may provide us clues to differentiate artifacts from true changes on the electrocardiogram. An improved understanding of the artifacts generated by electrocautery and their identifying characteristics is important to avoid misinterpretation, misdiagnosis, and hence mismanagement. This case report highlights the artifacts in electrocardiogram induced by electrocautery. Copyright © 2017 Elsevier Inc. All rights reserved.
Lancia, Loreto; Toccaceli, Andrea; Petrucci, Cristina; Romano, Silvio; Penco, Maria
2018-05-01
The purpose of the study was to compare the EASI system with the standard 12-lead surface electrocardiogram (ECG) for the accuracy in detecting the main electrocardiographic parameters (J point, PR, QT, and QRS) commonly monitored in patients with acute coronary syndromes or heart failure. In this observational comparative study, 253 patients who were consecutively admitted to the coronary care unit with acute coronary syndrome or heart failure were evaluated. In all patients, two complete 12-lead ECGs were acquired simultaneously. A total of 6,072 electrocardiographic leads were compared (3,036 standard and 3,036 EASI). No significant differences were found between the investigate parameters of the two measurement methods, either in patients with acute coronary syndrome or in those with heart failure. This study confirmed the accuracy of the EASI system in monitoring the main ECG parameters in patients admitted to the coronary care unit with acute coronary syndrome or heart failure.
Performance of human body communication-based wearable ECG with capacitive coupling electrodes
Sakuma, Jun; Anzai, Daisuke
2016-01-01
Wearable electrocardiogram (ECG) is attracting much attention in daily healthcare applications, and human body communication (HBC) technology provides an evident advantage in making the sensing electrodes of ECG also working for transmission through the human body. In view of actual usage in daily life, however, non-contact electrodes to the human body are desirable. In this Letter, the authors discussed the ECG circuit structure in the HBC-based wearable ECG for removing the common mode noise when employing non-contact capacitive coupling electrodes. Through the comparison of experimental results, they have shown that the authors’ proposed circuit structure with the third electrode directly connected to signal ground can provide an effect on common mode noise reduction similar to the usual drive-right-leg circuit, and a sufficiently good acquisition performance of ECG signals. PMID:27733931
Performance of human body communication-based wearable ECG with capacitive coupling electrodes.
Sakuma, Jun; Anzai, Daisuke; Wang, Jianqing
2016-09-01
Wearable electrocardiogram (ECG) is attracting much attention in daily healthcare applications, and human body communication (HBC) technology provides an evident advantage in making the sensing electrodes of ECG also working for transmission through the human body. In view of actual usage in daily life, however, non-contact electrodes to the human body are desirable. In this Letter, the authors discussed the ECG circuit structure in the HBC-based wearable ECG for removing the common mode noise when employing non-contact capacitive coupling electrodes. Through the comparison of experimental results, they have shown that the authors' proposed circuit structure with the third electrode directly connected to signal ground can provide an effect on common mode noise reduction similar to the usual drive-right-leg circuit, and a sufficiently good acquisition performance of ECG signals.
Nonlinear time series analysis of electrocardiograms
NASA Astrophysics Data System (ADS)
Bezerianos, A.; Bountis, T.; Papaioannou, G.; Polydoropoulos, P.
1995-03-01
In recent years there has been an increasing number of papers in the literature, applying the methods and techniques of Nonlinear Dynamics to the time series of electrical activity in normal electrocardiograms (ECGs) of various human subjects. Most of these studies are based primarily on correlation dimension estimates, and conclude that the dynamics of the ECG signal is deterministic and occurs on a chaotic attractor, whose dimension can distinguish between healthy and severely malfunctioning cases. In this paper, we first demonstrate that correlation dimension calculations must be used with care, as they do not always yield reliable estimates of the attractor's ``dimension.'' We then carry out a number of additional tests (time differencing, smoothing, principal component analysis, surrogate data analysis, etc.) on the ECGs of three ``normal'' subjects and three ``heavy smokers'' at rest and after mild exercising, whose cardiac rhythms look very similar. Our main conclusion is that no major dynamical differences are evident in these signals. A preliminary estimate of three to four basic variables governing the dynamics (based on correlation dimension calculations) is updated to five to six, when temporal correlations between points are removed. Finally, in almost all cases, the transition between resting and mild exercising seems to imply a small increase in the complexity of cardiac dynamics.
Bacharova, Ljuba; Ugander, Martin
2014-11-01
Conventional assessment of left ventricular hypertrophy (LVH) using the electrocardiogram (ECG), for example, by the Sokolow-Lyon, Romhilt-Estes or Cornell criteria, have relied on assessing changes in the amplitude and/or duration of the QRS complex of the ECG to quantify LV mass. ECG measures of LV mass have typically been validated by imaging with echocardiography or cardiovascular magnetic resonance imaging (CMR). However, LVH can be the result of diverse etiologies, and LVH is also characterized by pathological changes in myocardial tissue characteristics on the genetic, molecular, cellular, and tissue level beyond a pure increase in the number of otherwise normal cardiomyocytes. For example, slowed conduction velocity through the myocardium, which can be due to diffuse myocardial fibrosis, has been shown to be an important determinant of conventional ECG LVH criteria regardless of LV mass. Myocardial tissue characterization by CMR has emerged to not only quantify LV mass, but also detect and quantify the extent and severity of focal or diffuse myocardial fibrosis, edema, inflammation, myocarditis, fatty replacement, myocardial disarray, and myocardial deposition of amyloid proteins (amyloidosis), glycolipids (Fabry disease), or iron (siderosis). This can be undertaken using CMR techniques including late gadolinium enhancement (LGE), T1 mapping, T2 mapping, T2* mapping, extracellular volume fraction (ECV) mapping, fat/water-weighted imaging, and diffusion tensor CMR. This review presents an overview of current and emerging concepts regarding the diagnostic possibilities of both ECG and CMR for LVH in an attempt to narrow gaps in our knowledge regarding the ECG diagnosis of LVH. © 2014 Wiley Periodicals, Inc.
Yoshimatsu, Yu; Ishizaka, Tomomichi; Chiba, Katsuyoshi; Mori, Kazuhiko
2018-05-10
Drug-induced cardiac electrophysiological abnormalities accompanied by hypoglycemia or hyperglycemia increase the risk for life-threatening arrhythmia. To assess the drug-induced cardiotoxic potential associated with extraordinary blood glucose (GLU) levels, the effect of gatifloxacin (GFLX) which was frequently associated with GLU abnormality and QT/QTc prolongations in the clinic on blood GLU and electrocardiogram (ECG) parameters was investigated in cynomolgus monkeys (n=4) given GFLX orally in an ascending dose regimen (10, 30, 60 and 100 mg/kg). Simultaneous and sequential GLU and ECG monitoring with a continuous GLU monitoring system and Holter ECG, respectively, were conducted for 24 h under free-moving conditions. Consequently, GFLX at 30 and 60 mg/kg dose-dependently induced a transient decrease in GLU without any ECG abnormality 2-4 h postdose. Highest dose of 100 mg/kg caused severe hypoglycemia with a mean GLU of <30 mg/dL, accompanied by remarkable QT/QTc prolongations by 20-30% in all animals. In contrast, hyperglycemia without QT/QTc prolongations was noted 24 h after dosing in one animal. A close correlation between GLU and QTc values was observed in animals treated with 100 mg/kg, suggesting that GFLX-induced hypoglycemia enhanced QT/QTc prolongations. Furthermore, the 24-h sequential GLU monitoring data clearly distinguished between GFLX-induced GLU abnormality and physiological GLU changes influenced by feeding throughout the day. In conclusion, the combined assessment of continuous GLU and ECG monitoring is valuable in predicting the drug-induced cardio-electrophysiological risk associated with both GLU and ECG abnormalities.
ECG Sensor Card with Evolving RBP Algorithms for Human Verification.
Tseng, Kuo-Kun; Huang, Huang-Nan; Zeng, Fufu; Tu, Shu-Yi
2015-08-21
It is known that cardiac and respiratory rhythms in electrocardiograms (ECGs) are highly nonlinear and non-stationary. As a result, most traditional time-domain algorithms are inadequate for characterizing the complex dynamics of the ECG. This paper proposes a new ECG sensor card and a statistical-based ECG algorithm, with the aid of a reduced binary pattern (RBP), with the aim of achieving faster ECG human identity recognition with high accuracy. The proposed algorithm has one advantage that previous ECG algorithms lack-the waveform complex information and de-noising preprocessing can be bypassed; therefore, it is more suitable for non-stationary ECG signals. Experimental results tested on two public ECG databases (MIT-BIH) from MIT University confirm that the proposed scheme is feasible with excellent accuracy, low complexity, and speedy processing. To be more specific, the advanced RBP algorithm achieves high accuracy in human identity recognition and is executed at least nine times faster than previous algorithms. Moreover, based on the test results from a long-term ECG database, the evolving RBP algorithm also demonstrates superior capability in handling long-term and non-stationary ECG signals.
Community-Based ECG Monitoring System for Patients with Cardiovascular Diseases.
Lin, Bor-Shyh; Wong, Alice M; Tseng, Kevin C
2016-04-01
This study aims to develop a community-based electrocardiogram (ECG) monitoring system for cardiac outpatients to wirelessly detect heart rate, provide personalized healthcare, and enhance interactive social contact because of the prevalence of deaths from cardiovascular disease and the growing problem of aging in the world. The system not only strengthens the performance of the ECG monitoring system but also emphasizes the ergonomic design of wearable devices and user interfaces. In addition, it enables medical professionals to diagnose cardiac symptoms remotely and electronically manage medical reports and suggestions. The experimental result shows high performance of the dry electrode, even in dynamic conditions. The comparison result with different ECG healthcare systems shows the essential factors that the system should possess and the capability of the proposed system. Finally, a user survey was conducted based on the unified theory of acceptance and users of technology (UTAUT) model.
Classification of cardiac patient states using artificial neural networks
Kannathal, N; Acharya, U Rajendra; Lim, Choo Min; Sadasivan, PK; Krishnan, SM
2003-01-01
Electrocardiogram (ECG) is a nonstationary signal; therefore, the disease indicators may occur at random in the time scale. This may require the patient be kept under observation for long intervals in the intensive care unit of hospitals for accurate diagnosis. The present study examined the classification of the states of patients with certain diseases in the intensive care unit using their ECG and an Artificial Neural Networks (ANN) classification system. The states were classified into normal, abnormal and life threatening. Seven significant features extracted from the ECG were fed as input parameters to the ANN for classification. Three neural network techniques, namely, back propagation, self-organizing maps and radial basis functions, were used for classification of the patient states. The ANN classifier in this case was observed to be correct in approximately 99% of the test cases. This result was further improved by taking 13 features of the ECG as input for the ANN classifier. PMID:19649222
Khush, Kiran K.; Menza, Rebecca; Nguyen, John; Goldstein, Benjamin A.; Zaroff, Jonathan G.; Drew, Barbara J.
2012-01-01
Background Current regulations require that all cardiac allograft offers for transplantation must include an interpreted 12-lead electrocardiogram (ECG). However, little is known about the expected ECG findings in potential organ donors, or the clinical significance of any identified abnormalities in terms of cardiac allograft function and suitability for transplantation. Methods and Results A single experienced reviewer interpreted the first ECG obtained after brainstem herniation in 980 potential organ donors managed by the California Transplant Donor Network from 2002-2007. ECG abnormalities were summarized, and associations between specific ECG findings and cardiac allograft utilization for transplantation were studied. ECG abnormalities were present in 51% of all cases reviewed. The most common abnormalities included voltage criteria for left ventricular hypertrophy (LVH), prolongation of the corrected QT interval (QTc), and repolarization changes (ST/T wave abnormalities). Fifty seven percent of potential cardiac allografts in this cohort were accepted for transplantation. LVH on ECG was a strong predictor of allograft non-utilization. No significant associations were seen between QTc prolongation, repolarization changes and allograft utilization for transplantation, after adjusting for donor clinical variables and echocardiographic findings. Conclusions We have performed the first comprehensive study of ECG findings in potential donors for cardiac transplantation. Many of the common ECG abnormalities seen in organ donors may result from the heightened state of sympathetic activation that occurs after brainstem herniation, and are not associated with allograft utilization for transplantation. PMID:22615333
An Adaptive and Time-Efficient ECG R-Peak Detection Algorithm.
Qin, Qin; Li, Jianqing; Yue, Yinggao; Liu, Chengyu
2017-01-01
R-peak detection is crucial in electrocardiogram (ECG) signal analysis. This study proposed an adaptive and time-efficient R-peak detection algorithm for ECG processing. First, wavelet multiresolution analysis was applied to enhance the ECG signal representation. Then, ECG was mirrored to convert large negative R-peaks to positive ones. After that, local maximums were calculated by the first-order forward differential approach and were truncated by the amplitude and time interval thresholds to locate the R-peaks. The algorithm performances, including detection accuracy and time consumption, were tested on the MIT-BIH arrhythmia database and the QT database. Experimental results showed that the proposed algorithm achieved mean sensitivity of 99.39%, positive predictivity of 99.49%, and accuracy of 98.89% on the MIT-BIH arrhythmia database and 99.83%, 99.90%, and 99.73%, respectively, on the QT database. By processing one ECG record, the mean time consumptions were 0.872 s and 0.763 s for the MIT-BIH arrhythmia database and QT database, respectively, yielding 30.6% and 32.9% of time reduction compared to the traditional Pan-Tompkins method.
An Adaptive and Time-Efficient ECG R-Peak Detection Algorithm
Qin, Qin
2017-01-01
R-peak detection is crucial in electrocardiogram (ECG) signal analysis. This study proposed an adaptive and time-efficient R-peak detection algorithm for ECG processing. First, wavelet multiresolution analysis was applied to enhance the ECG signal representation. Then, ECG was mirrored to convert large negative R-peaks to positive ones. After that, local maximums were calculated by the first-order forward differential approach and were truncated by the amplitude and time interval thresholds to locate the R-peaks. The algorithm performances, including detection accuracy and time consumption, were tested on the MIT-BIH arrhythmia database and the QT database. Experimental results showed that the proposed algorithm achieved mean sensitivity of 99.39%, positive predictivity of 99.49%, and accuracy of 98.89% on the MIT-BIH arrhythmia database and 99.83%, 99.90%, and 99.73%, respectively, on the QT database. By processing one ECG record, the mean time consumptions were 0.872 s and 0.763 s for the MIT-BIH arrhythmia database and QT database, respectively, yielding 30.6% and 32.9% of time reduction compared to the traditional Pan-Tompkins method. PMID:29104745
Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement.
Lee, Seung Min; Sim, Kyo Sik; Kim, Ko Keun; Lim, Yong Gyu; Park, Kwang Suk
2010-05-01
Capacitive electrocardiogram (ECG) measurement over clothing requires large electrodes that can remain in contact with curved body surfaces to increase the signal-to-noise ratio (SNR). In this article, we propose a new, thin, and flexible active electrode for use as a capacitive ECG measurement electrode. This electrode contains a shielding plate over its surface and it is extremely thin and can bend freely to cover larger body surfaces of the curve-shaped human torso. We evaluated the characteristics of flexible active electrodes under conditions of varying cloth thickness, electrode size, and contacting pressure. Electrodes of two sizes (45 and 12 cm(2)) were attached to a chest belt to measure the ECG from the human torso, and the results obtained for both the sizes were compared. Cloth thickness and electrode size showed a dominant effect on the SNR, whereas contacting pressure had almost no effect. The flexible active electrodes attached to chest belts wrapped closely and uniformly over the curved surface of the torso and SNR was increased with an increase in electrode size. Although the ECG signal became more distorted as the cloth thickness increased, the larger-sized flexible active electrode (45 cm(2)) showed less distortion than the smaller-sized one (12 cm(2)).
Gogas, Bill D; Iliodromitis, Efstathios K; Leftheriotis, Dionyssios I; Flevari, Panagiota G; Rallidis, Loukianos S; Kremastinos, Dimitrios T
2011-04-14
Severe hyperkalaemia is a life threatening electrolyte abnormality that if not treated urgently, might cause electric death. Hyperkalaemia induced electrocardiogram (ECG) alterations vary according to the levels and rate of increase of potassium concentration ([K(+)]) in the extracellular milieu but the paradox is that not all these cases provide ECG changes. We describe the first case in the literature of transient sinus rhythm (SR) recovery despite severe hyperkalaemia in a 57-year-old (yo) male patient with impressive ECG changes considering the heart rhythm and QRS morphology. We also review the literature for the mechanism of ECG alterations induced by hyperkalaemia. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
An ultra-high input impedance ECG amplifier for long-term monitoring of athletes.
Gargiulo, Gaetano; Bifulco, Paolo; Cesarelli, Mario; Ruffo, Mariano; Romano, Maria; Calvo, Rafael A; Jin, Craig; van Schaik, André
2010-01-01
We present a new, low-power electrocardiogram (ECG) recording system with an ultra-high input impedance that enables the use of long-lasting, dry electrodes. The system incorporates a low-power Bluetooth module for wireless connectivity and is designed to be suitable for long-term monitoring during daily activities. The new system using dry electrodes was compared with a clinically approved ECG reference system using gelled Ag/AgCl electrodes and performance was found to be equivalent. In addition, the system was used to monitor an athlete during several physical tasks, and a good quality ECG was obtained in all cases, including when the athlete was totally submerged in fresh water.
Tic Reduction with Risperidone Versus Pimozide in a Randomized, Double-Blind, Crossover Trial
ERIC Educational Resources Information Center
Gilbert, Donald L.; Batterson, J. Robert; Sethuraman, Gopalan; Sallee, Floyd R.
2004-01-01
Objective: To compare the tic suppression, electrocardiogram (ECG) changes, weight gain, and side effect profiles of pimozide versus risperidone in children and adolescents with tic disorders. Method: This was a randomized, double-blind, crossover (evaluable patient analysis) study. Nineteen children aged 7 to 17 years with Tourette's or chronic…
Chai, Norin; Pouchelon, Jean Louis; Bouvard, Jonathan; Sillero, Leonor Camacho; Huynh, Minh; Segalini, Vincent; Point, Lisa; Croce, Veronica; Rigaux, Goulven; Highwood, Jack; Chetboul, Valérie
2016-03-01
Electrocardiography represents a relevant diagnostic tool for detecting cardiac disease in animals. Elephants can present various congenital and acquired cardiovascular diseases. However, few electrophysiologic studies have been reported in captive elephants, mainly due to challenging technical difficulties in obtaining good-quality electrocardiogram (ECG) tracings, and no data are currently available for free-ranging Asian elephants (Elephas maximus). The purpose of this pilot prospective study was to evaluate the feasibility of using a simple method for recording ECG tracings in wild, apparently healthy, unsedated Asian elephants (n = 7) in the standing position. Successful six-lead recordings (I, II, III, aVR, aVL, and aVF) were obtained, with the aVL lead providing the best-quality tracings in most animals. Variables measured in the aVL lead included heart rate, amplitudes and duration of the P waves, QRS complexes, T and U waves, and duration of the PR, QT, and QU intervals. A negative deflection following positive P waves, representative of an atrial repolarization wave (Ta wave), was observed for five out of the seven elephants.
Locati, E T; Moya, A; Oliveira, M; Tanner, H; Willems, R; Lunati, M; Brignole, M
2016-08-01
SYNARR-Flash study (Monitoring of SYNcopes and/or sustained palpitations of suspected ARRhythmic origin) is an international, multicentre, observational, prospective trial designed to evaluate the role of external 4-week electrocardiogram (ECG) monitoring in clinical work-up of unexplained syncope and/or sustained palpitations of suspected arrhythmic origin. Consecutive patients were enrolled within 1 month after unexplained syncope or palpitations (index event) after being discharged from emergency room or hospitalization without a conclusive diagnosis. A 4-week ECG monitoring was obtained by external high-capacity loop recorder (SpiderFlash-T(®), Sorin) storing patient-activated and auto-triggered tracings. Diagnostic monitorings included (i) conclusive events with reoccurrence of syncope or palpitation with concomitant ECG recording (with/without arrhythmias) and (ii) events with asymptomatic predefined significant arrhythmias (sustained supraventricular or ventricular tachycardia, advanced atrio-ventricular block, sinus bradycardia <30 b.p.m., pauses >6 s). SYNARR-Flash study enrolled 395 patients (57.7% females, 56.9 ± 18.7 years, 28.1% with syncope, and 71.9% with palpitations) from 10 European centres. For syncope, the 4-week diagnostic yield was 24.5%, and predictors of diagnostic events were early start of recording (0-15 vs. >15 days after index event) (OR 6.2, 95% CI 1.3-29.6, P = 0.021) and previous history of supraventricular arrhythmias (OR 3.6, 95% CI 1.4-9.7, P = 0.018). For palpitations, the 4-week diagnostic yield was 71.6% and predictors of diagnostic events were history of recurrent palpitations (P < 0.001) and early start of recording (P = 0.001). The 4-week external ECG monitoring can be considered as first-line tool in the diagnostic work-up of syncope and palpitation. Early recorder use, history of supraventricular arrhythmia, and frequent previous events increased the likelihood of diagnostic events during the 4-week external ECG monitoring. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.
Man, Sumche; Maan, Arie C; Schalij, Martin J; Swenne, Cees A
2015-01-01
In the course of time, electrocardiography has assumed several modalities with varying electrode numbers, electrode positions and lead systems. 12-lead electrocardiography and 3-lead vectorcardiography have become particularly popular. These modalities developed in parallel through the mid-twentieth century. In the same time interval, the physical concepts underlying electrocardiography were defined and worked out. In particular, the vector concept (heart vector, lead vector, volume conductor) appeared to be essential to understanding the manifestations of electrical heart activity, both in the 12-lead electrocardiogram (ECG) and in the 3-lead vectorcardiogram (VCG). Not universally appreciated in the clinic, the vectorcardiogram, and with it the vector concept, went out of use. A revival of vectorcardiography started in the 90's, when VCGs were mathematically synthesized from standard 12-lead ECGs. This facilitated combined electrocardiography and vectorcardiography without the need for a special recording system. This paper gives an overview of these historical developments, elaborates on the vector concept and seeks to define where VCG analysis/interpretation can add diagnostic/prognostic value to conventional 12-lead ECG analysis. Copyright © 2015 Elsevier Inc. All rights reserved.
Impact of teaching and assessment format on electrocardiogram interpretation skills.
Raupach, Tobias; Hanneforth, Nathalie; Anders, Sven; Pukrop, Tobias; Th J ten Cate, Olle; Harendza, Sigrid
2010-07-01
Interpretation of the electrocardiogram (ECG) is a core clinical skill that should be developed in undergraduate medical education. This study assessed whether small-group peer teaching is more effective than lectures in enhancing medical students' ECG interpretation skills. In addition, the impact of assessment format on study outcome was analysed. Two consecutive cohorts of Year 4 medical students (n=335) were randomised to receive either traditional ECG lectures or the same amount of small-group, near-peer teaching during a 6-week cardiorespiratory course. Before and after the course, written assessments of ECG interpretation skills were undertaken. Whereas this final assessment yielded a considerable amount of credit points for students in the first cohort, it was merely formative in nature for the second cohort. An unannounced retention test was applied 8 weeks after the end of the cardiovascular course. A significant advantage of near-peer teaching over lectures (effect size 0.33) was noted only in the second cohort, whereas, in the setting of a summative assessment, both teaching formats appeared to be equally effective. A summative instead of a formative assessment doubled the performance increase (Cohen's d 4.9 versus 2.4), mitigating any difference between teaching formats. Within the second cohort, the significant difference between the two teaching formats was maintained in the retention test (p=0.017). However, in both cohorts, a significant decrease in student performance was detected during the 8 weeks following the cardiovascular course. Assessment format appeared to be more powerful than choice of instructional method in enhancing student learning. The effect observed in the second cohort was masked by an overriding incentive generated by the summative assessment in the first cohort. This masking effect should be considered in studies assessing the effectiveness of different teaching methods.
A novel ECG data compression method based on adaptive Fourier decomposition
NASA Astrophysics Data System (ADS)
Tan, Chunyu; Zhang, Liming
2017-12-01
This paper presents a novel electrocardiogram (ECG) compression method based on adaptive Fourier decomposition (AFD). AFD is a newly developed signal decomposition approach, which can decompose a signal with fast convergence, and hence reconstruct ECG signals with high fidelity. Unlike most of the high performance algorithms, our method does not make use of any preprocessing operation before compression. Huffman coding is employed for further compression. Validated with 48 ECG recordings of MIT-BIH arrhythmia database, the proposed method achieves the compression ratio (CR) of 35.53 and the percentage root mean square difference (PRD) of 1.47% on average with N = 8 decomposition times and a robust PRD-CR relationship. The results demonstrate that the proposed method has a good performance compared with the state-of-the-art ECG compressors.
Real-time ECG monitoring and arrhythmia detection using Android-based mobile devices.
Gradl, Stefan; Kugler, Patrick; Lohmuller, Clemens; Eskofier, Bjoern
2012-01-01
We developed an application for Android™-based mobile devices that allows real-time electrocardiogram (ECG) monitoring and automated arrhythmia detection by analyzing ECG parameters. ECG data provided by pre-recorded files or acquired live by accessing a Shimmer™ sensor node via Bluetooth™ can be processed and evaluated. The application is based on the Pan-Tompkins algorithm for QRS-detection and contains further algorithm blocks to detect abnormal heartbeats. The algorithm was validated using the MIT-BIH Arrhythmia and MIT-BIH Supraventricular Arrhythmia databases. More than 99% of all QRS complexes were detected correctly by the algorithm. Overall sensitivity for abnormal beat detection was 89.5% with a specificity of 80.6%. The application is available for download and may be used for real-time ECG-monitoring on mobile devices.
... disease affects your heart's muscle, blood vessels, and electrical system and is the leading cause of death ... An electrocardiogram (EKG or ECG) measures your heart's electrical activity by placing small electrodes on your chest, ...
Atrial Fibrillation in Children
... of the following tests: Electrocardiogram (also called an EKG or ECG) — this is a noninvasive test used ... About Arrhythmia Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...
Improving the quality of the ECG signal by filtering in wavelet transform domain
NASA Astrophysics Data System (ADS)
DzierŻak, RóŻa; Surtel, Wojciech; Dzida, Grzegorz; Maciejewski, Marcin
2016-09-01
The article concerns the research methods of noise reduction occurring in the ECG signals. The method is based on the use of filtration in wavelet transform domain. The study was conducted on two types of signal - received during the rest of the patient and obtained during physical activity. For each of the signals 3 types of filtration were used. The study was designed to determine the effectiveness of various wavelets for de-noising signals obtained in both cases. The results confirm the suitability of the method for improving the quality of the electrocardiogram in case of both types of signals.
Designing ECG-based physical unclonable function for security of wearable devices.
Shihui Yin; Chisung Bae; Sang Joon Kim; Jae-Sun Seo
2017-07-01
As a plethora of wearable devices are being introduced, significant concerns exist on the privacy and security of personal data stored on these devices. Expanding on recent works of using electrocardiogram (ECG) as a modality for biometric authentication, in this work, we investigate the possibility of using personal ECG signals as the individually unique source for physical unclonable function (PUF), which eventually can be used as the key for encryption and decryption engines. We present new signal processing and machine learning algorithms that learn and extract maximally different ECG features for different individuals and minimally different ECG features for the same individual over time. Experimental results with a large 741-subject in-house ECG database show that the distributions of the intra-subject (same person) Hamming distance of extracted ECG features and the inter-subject Hamming distance have minimal overlap. 256-b random numbers generated from the ECG features of 648 (out of 741) subjects pass the NIST randomness tests.
Ravi, Prasad; Ashwath, Ravi; Strainic, James; Li, Hong; Steinberg, Jon; Snyder, Christopher
2016-01-01
Left axis deviation (LAD) on the electrocardiogram (ECG) is associated with congenital heart disease (CHD), prompting the clinician to order further testing when evaluating a patient with this finding. The purpose is to (1) compare the physical examination (PE) by a pediatric cardiologist to echocardiogram (ECHO) findings in patients with LAD on resting ECG and (2) assess cost of performing ECHO on all patients with LAD on ECG. An IRB approved, retrospective cohort study was performed on patients with LAD (QRS axis ≥0° to -90°) on ECG between 01/02 and 12/12. age >0.25 and <18 years, non-postoperative, and PE and ECHO by pediatric cardiologist. A decision tree model analyzed cost of ECHO in patients with LAD and normal/abnormal PE. Cost of complete ECHO ($239.00) was obtained from 2014 Medicare reimbursement rates. A total of 146 patients met inclusion criteria with 46.5% (68) having normal PE and ECHO, 1.4% (2) having normal PE and abnormal ECHO, 47.3% (69) having abnormal PE and ECHO, and 4.8% (7) having an abnormal PE and normal ECHO. Sensitivity and specificity of PE for detecting abnormalities in this population was 97% and 90%. Positive and negative predictive value of PE was 91% and 97.5%. In patients with normal PE, the cost to identify an ECHO abnormality was $8365, and $263 for those with abnormal PE. In presence of LAD on ECG, the sensitivity, specificity, and positive and negative predictive values of PE by a pediatric cardiologist are excellent at identifying CHD. Performing an ECHO on patients with LAD on ECG is only cost effective in the presence of an abnormal PE. In the presence of normal PE, there is a possibility of missing incidental structural cardiac disease in approximately 2% if an ECHO is not performed. © 2015 Wiley Periodicals, Inc.
Tuohinen, Suvi Sirkku; Keski-Pukkila, Konsta; Skyttä, Tanja; Huhtala, Heini; Virtanen, Vesa; Kellokumpu-Lehtinen, Pirkko-Liisa; Raatikainen, Pekka; Nikus, Kjell
2018-04-01
Early electrocardiogram (ECG) changes after breast cancer radiotherapy (RT) have been reported, but their characteristics and associated factors are largely unknown. This study aimed to explore early RT-induced ECG changes and to compare them with echocardiography changes. Sixty eligible patients with chemotherapy-naïve left-sided and 20 with right-sided breast cancer were evaluated with echocardiography, blood samples and ECG before and after RT. RT-induced ECG changes in the anterior leads. T-Wave changes were most frequent. T-Wave decline was associated independently with patient age (β=-0.245, p=0.005), mean heart radiation dose (β=1.252, p=0.001) and global systolic strain rate change (β=7.943, p=0.002). T-Wave inversion was associated independently with mean heart radiation dose (β=0.143, p<0.001), global longitudinal strain change (β=0.053, p=0.017) and posterior calibrated integrated backscatter (β=-0.022, p=0.049). RT-induced ECG changes were prevalent and associated with functional and structural changes in echocardiography. ECG could be used for post-RT cardiac screening. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Heart rate calculation from ensemble brain wave using wavelet and Teager-Kaiser energy operator.
Srinivasan, Jayaraman; Adithya, V
2015-01-01
Electroencephalogram (EEG) signal artifacts are caused by various factors, such as, Electro-oculogram (EOG), Electromyogram (EMG), Electrocardiogram (ECG), movement artifact and line interference. The relatively high electrical energy cardiac activity causes EEG artifacts. In EEG signal processing the general approach is to remove the ECG signal. In this paper, we introduce an automated method to extract the ECG signal from EEG using wavelet and Teager-Kaiser energy operator for R-peak enhancement and detection. From the detected R-peaks the heart rate (HR) is calculated for clinical diagnosis. To check the efficiency of our method, we compare the HR calculated from ECG signal recorded in synchronous with EEG. The proposed method yields a mean error of 1.4% for the heart rate and 1.7% for mean R-R interval. The result illustrates that, proposed method can be used for ECG extraction from single channel EEG and used in clinical diagnosis like estimation for stress analysis, fatigue, and sleep stages classification studies as a multi-model system. In addition, this method eliminates the dependence of additional synchronous ECG in extraction of ECG from EEG signal process.
Lee, Kwang Jin; Lee, Boreom
2016-01-01
Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR. PMID:27376296
Lee, Kwang Jin; Lee, Boreom
2016-07-01
Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR.
Yang, Kai; Jiang, Xuejun; Cheng, Shuqun; Chen, Chengzhi; Cao, Xianqing; Tu, Baijie
2016-01-01
Objective: To evaluate the effects of occupational exposures to coke oven emissions (COEs) and benzo[a]pyrene (B[a]P) on the prevalence of hypertension and abnormal electrocardiogram (ECG) in coke oven workers. Methods: We included 880 coke oven workers and 710 oxygen employees in the exposed and control groups, respectively. Blood pressure (BP), ECG, blood lipid levels, and glucose levels of all subjects were measured. COE and B[a]P concentrations at the bottom, side, and top of the oven and control plants were estimated by weighing and high-performance liquid chromatography. Results: The COE concentration at the top and side was higher than that at the bottom (P < 0.05). The levels of B[a]P at the top and side significantly exceeded the limit value. Abnormal BP, ECG, the detection ratio of hypertension and left ventricular high voltage were significantly greater in the exposed group than in the control group (P < 0.05). The logistic regression analysis results revealed that age and B[a]P exposure were risk factors for hypertension in coke oven workers (P < 0.05) and both were risk factors for abnormal ECG (P < 0.05). Moreover, B[a]P exposure, age, and gender were risk factors for impaired fasting glucose in coke oven workers (P < 0.05). Conclusions: B[a]P and COE exposures are risk factors for hypertension and abnormal ECG in coke oven workers. PMID:27885241
Singularity detection by wavelet approach: application to electrocardiogram signal
NASA Astrophysics Data System (ADS)
Jalil, Bushra; Beya, Ouadi; Fauvet, Eric; Laligant, Olivier
2010-01-01
In signal processing, the region of abrupt changes contains the most of the useful information about the nature of the signal. The region or the points where these changes occurred are often termed as singular point or singular region. The singularity is considered to be an important character of the signal, as it refers to the discontinuity and interruption present in the signal and the main purpose of the detection of such singular point is to identify the existence, location and size of those singularities. Electrocardiogram (ECG) signal is used to analyze the cardiovascular activity in the human body. However the presence of noise due to several reasons limits the doctor's decision and prevents accurate identification of different pathologies. In this work we attempt to analyze the ECG signal with energy based approach and some heuristic methods to segment and identify different signatures inside the signal. ECG signal has been initially denoised by empirical wavelet shrinkage approach based on Steins Unbiased Risk Estimate (SURE). At the second stage, the ECG signal has been analyzed by Mallat approach based on modulus maximas and Lipschitz exponent computation. The results from both approaches has been discussed and important aspects has been highlighted. In order to evaluate the algorithm, the analysis has been done on MIT-BIH Arrhythmia database; a set of ECG data records sampled at a rate of 360 Hz with 11 bit resolution over a 10mv range. The results have been examined and approved by medical doctors.
The Cardiac Safety Research Consortium ECG database.
Kligfield, Paul; Green, Cynthia L
2012-01-01
The Cardiac Safety Research Consortium (CSRC) ECG database was initiated to foster research using anonymized, XML-formatted, digitized ECGs with corresponding descriptive variables from placebo- and positive-control arms of thorough QT studies submitted to the US Food and Drug Administration (FDA) by pharmaceutical sponsors. The database can be expanded to other data that are submitted directly to CSRC from other sources, and currently includes digitized ECGs from patients with genotyped varieties of congenital long-QT syndrome; this congenital long-QT database is also linked to ambulatory electrocardiograms stored in the Telemetric and Holter ECG Warehouse (THEW). Thorough QT data sets are available from CSRC for unblinded development of algorithms for analysis of repolarization and for blinded comparative testing of algorithms developed for the identification of moxifloxacin, as used as a positive control in thorough QT studies. Policies and procedures for access to these data sets are available from CSRC, which has developed tools for statistical analysis of blinded new algorithm performance. A recently approved CSRC project will create a data set for blinded analysis of automated ECG interval measurements, whose initial focus will include comparison of four of the major manufacturers of automated electrocardiographs in the United States. CSRC welcomes application for use of the ECG database for clinical investigation. Copyright © 2012 Elsevier Inc. All rights reserved.
Signal separation by nonlinear projections: The fetal electrocardiogram
NASA Astrophysics Data System (ADS)
Schreiber, Thomas; Kaplan, Daniel T.
1996-05-01
We apply a locally linear projection technique which has been developed for noise reduction in deterministically chaotic signals to extract the fetal component from scalar maternal electrocardiographic (ECG) recordings. Although we do not expect the maternal ECG to be deterministic chaotic, typical signals are effectively confined to a lower-dimensional manifold when embedded in delay space. The method is capable of extracting fetal heart rate even when the fetal component and the noise are of comparable amplitude. If the noise is small, more details of the fetal ECG, like P and T waves, can be recovered.
ECG CHANGES AFTER X-RAY IRRADIATION OF THE HEART REGION (in German)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gral, T.; Gral, J.
1963-03-01
The problem of radioinduced damage of the myocardium after irradiation of the heart region for mammary carcinoma or intrathoracic tumors is discussed. Analysis of patient material, including 34 cases with mammary carcinomas on the left side and 14 cases with intrathoracic tumors, showed considerable ECG-changes (ECG = electrocardiogram) in 18 and in 6 cases, respectively. Because of these results, it is assumed that damage of the myocardium caused by irradiation is possible during tangential irradiation of mammary carcinomas on the left side. This could be of importance in the future wellbeing of the patients. (auth)
Diabetic hyperglycemic hyperosmolar syndrome
... glucose Evaluation for possible causes may include: Blood cultures Chest x-ray Electrocardiogram (ECG) Urinalysis Treatment At the start of treatment, the goal is to correct the water loss. This will improve the blood pressure, urine output, ...
Heart Health Tests for Diabetes Patients
... or fluids in the body. They include: Electrocardiogram ("EKG" or "ECG") This test measures the electrical activity ... Tools & Resources Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...
Soliman, Elsayed Z
2008-01-01
The similarity between and the number of limb lead cables play an important role in the frequency of incorrect connection of limb electrodes. Hence, a modified electrocardiogram (ECG) acquisition procedure is proposed in this brief communication, whereby the left-leg (LL) and right-leg (RL) electrode cables are combined into 1 cable, referred to as combined LL/RL cable. The electrode wires in the combined LL/RL cable are connected to 2 electrodes placed on both sides of the LL. The combined LL/RL cable is unique enough (being thicker) not to be mistaken with the upper limb electrode cables. The proposed modification will not in any way influence the ECG waveforms or amplitudes, and it can be expected to substantially reduce incorrect limb electrode placements.
Arrhythmic hazard map for a 3D whole-ventricles model under multiple ion channel block.
Okada, Jun-Ichi; Yoshinaga, Takashi; Kurokawa, Junko; Washio, Takumi; Furukawa, Tetsushi; Sawada, Kohei; Sugiura, Seiryo; Hisada, Toshiaki
2018-05-10
To date, proposed in silico models for preclinical cardiac safety testing are limited in their predictability and usability. We previously reported a multi-scale heart simulation that accurately predicts arrhythmogenic risk for benchmark drugs. We extend this approach and report the first comprehensive hazard map of drug-induced arrhythmia based on the exhaustive in silico electrocardiogram (ECG) database of drug effects, developed using a petaflop computer. A total of 9075 electrocardiograms constitute the five-dimensional hazard map, with coordinates representing the extent of the block of each of the five ionic currents (rapid delayed rectifier potassium current (IKr), fast (INa) and late (INa,L) components of the sodium current, L-type calcium current (ICa,L) and slow delayed rectifier current (IKs)), involved in arrhythmogenesis. Results of the evaluation of arrhythmogenic risk based on this hazard map agreed well with the risk assessments reported in three references. ECG database also suggested that the interval between the J-point and the T-wave peak is a superior index of arrhythmogenicity compared to other ECG biomarkers including the QT interval. Because concentration-dependent effects on electrocardiograms of any drug can be traced on this map based on in vitro current assay data, its arrhythmogenic risk can be evaluated without performing costly and potentially risky human electrophysiological assays. Hence, the map serves as a novel tool for use in pharmaceutical research and development. This article is protected by copyright. All rights reserved.
Lin, Lu; Wang, Yi-Ning; Kong, Ling-Yan; Jin, Zheng-Yu; Lu, Guang-Ming; Zhang, Zhao-Qi; Cao, Jian; Li, Shuo; Song, Lan; Wang, Zhi-Wei; Zhou, Kang; Wang, Ming
2013-01-01
Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequential scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrillation referred for a second-generation 128-slice DSCT coronary angiography were included in the prospective study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG-triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel-lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each patient were compared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean HR (t=1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by reader1 and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by reader1 and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27±0.19 vs. 1.25±0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively ECG-gated spiral scan, prospectively ECG-triggered sequential DSCT coronary angiography provides similarly diagnostically valuable images in patients with atrial fibrillation and significantly reduces radiation dose.
Xing, Na; Ji, Lizhen; Song, Jie; Ma, Jingchun; Li, Shangge; Ren, Zongming; Xu, Fei; Zhu, Jianping
2017-10-01
The electrocardiogram (ECG) of zebra fish (Danio rerio) expresses cardiac features that are similar to humans. Here we use sharp microelectrode measurements to obtain ECG characteristics in adult zebra fish and analyze the effects of cadmium chloride (CdCl 2 ) on the heart. We observe the overall changes of ECG parameters in different treatments (0.1 TU, 0.5 TU and 1.0 TU CdCl 2 ), including P wave, Q wave, R wave, S wave, T wave, PR interval (atrial contraction), QRS complex (ventricular depolarization), ST segment, and QT interval (ventricular repolarization). The trends of the ECG parameters showed some responses to the concentration and exposure time of CdCl 2 , but it was difficult to obtain more information about the useful indicators in water quality assessment depending on tendency analysis alone. A self-organizing map (SOM) showed that P values, R values, and T values were similar; R wave and T wave amplitude were similar; and most important, QRS value was similar to the CdCl 2 stress according to the classified data patterns including CdCl 2 stress (E) and ECG components based on the Ward linkage. It suggested that the duration of QRS complex was related to environmental stress E directly. The specification and evaluation of ECG parameters in Cd 2+ pollution suggested that there is a markedly significant correlation between QRS complex and CdCl 2 stress with the highest r (0.729) and the smallest p (0.002) among all ECG characteristics. In this case, it is concluded that QRS complex can be used as an indicator in the CdCl 2 stress assessment due to the lowest AIC data abased on the linear regression model between the CdCl 2 stress and ECG parameters. Copyright © 2017 Elsevier B.V. All rights reserved.
Patients With Type A Acute Aortic Dissection Presenting With an Abnormal Electrocardiogram.
Costin, Nathaniel I; Korach, Amit; Loor, Gabriel; Peterson, Mark D; Desai, Nimesh D; Trimarchi, Santi; de Vincentiis, Carlo; Ota, Takeyoshi; Reece, T Brett; Sundt, Thoralf M; Patel, Himanshu J; Chen, Edward P; Montgomery, Dan G; Nienaber, Christoph A; Isselbacher, Eric M; Eagle, Kim A; Gleason, Thomas G
2018-01-01
The electrocardiogram (ECG) is often used in the diagnosis of patients presenting with chest pain to emergency departments. Because chest pain is a common manifestation of type A acute aortic dissection (TAAAD), ECGs are obtained in much of this population. We evaluated the effect of particular ECG patterns on the diagnosis and treatment of TAAAD. TAAAD patients (N = 2,765) enrolled in the International Registry of Acute Aortic Dissection were stratified based on normal (n = 1,094 [39.6%]) and abnormal (n = 1,671 [60.4%]) findings on presenting ECGs and further subdivided according to specific ECG findings. Time data are presented in hours as medians (quartile 1 to quartile 3). Patients with ECGs with abnormal findings presented to the hospital sooner after symptom onset than those with ECGs with normal findings (1.4 [0.8 to 3.3] vs 2.0 [1.0 to 3.3]; p = 0.005). Specifically, this was seen in patients with infarction with new Q waves or ST elevation (1.3 [0.6 to 2.7] vs 1.5 [0.8 to 3.3]; p = 0.049). Interestingly, the time between symptom onset and diagnosis was longer with infarction with old Q waves (6.7 [3.2 to 18.4] vs 5.0 [2.9 to 11.8]; p = 0.034) and nonspecific ST-T changes (5.8 [3.0 to 13.8] vs 4.5 [2.8 to 10.5]; p = 0.002). Surgical mortality was higher in patients with abnormal ECG findings (20.6% vs 11.9%, p < 0.001), especially in those with ischemia by ECG (25.7% vs 16.8%, p < 0.001) and infarction with new Q waves or ST elevation (30.1% vs 17.1%, p < 0.001). TAAAD patients presenting with abnormal ECG results are sicker, have more in-hospital complications, and are more likely to die. The frequency of nonspecific ST-T abnormalities and its association with delay in diagnosis and treatment presents an opportunity for practice improvement. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Individual Biometric Identification Using Multi-Cycle Electrocardiographic Waveform Patterns.
Lee, Wonki; Kim, Seulgee; Kim, Daeeun
2018-03-28
The electrocardiogram (ECG) waveform conveys information regarding the electrical property of the heart. The patterns vary depending on the individual heart characteristics. ECG features can be potentially used for biometric recognition. This study presents a new method using the entire ECG waveform pattern for matching and demonstrates that the approach can potentially be employed for individual biometric identification. Multi-cycle ECG signals were assessed using an ECG measuring circuit, and three electrodes can be patched on the wrists or fingers for considering various measurements. For biometric identification, our-fold cross validation was used in the experiments for assessing how the results of a statistical analysis will generalize to an independent data set. Four different pattern matching algorithms, i.e., cosine similarity, cross correlation, city block distance, and Euclidean distances, were tested to compare the individual identification performances with a single channel of ECG signal (3-wire ECG). To evaluate the pattern matching for biometric identification, the ECG recordings for each subject were partitioned into training and test set. The suggested method obtained a maximum performance of 89.9% accuracy with two heartbeats of ECG signals measured on the wrist and 93.3% accuracy with three heartbeats for 55 subjects. The performance rate with ECG signals measured on the fingers improved up to 99.3% with two heartbeats and 100% with three heartbeats of signals for 20 subjects.
ERIC Educational Resources Information Center
Jeffries, Pamela R.; Woolf, Shirley; Linde, Beverly
2003-01-01
Electrocardiogram technique was taught to 32 nursing students using a self-study module, lecture-demonstration, and hands-on learning laboratories and to 45 students using interactive multimedia CD-ROM with self-study module. Pre/postprogram data show satisfaction and score improvement was high for both, with no significant differences. (Contains…
Bradycardia as a Marker of Chronic Cocaine Use: A Novel Cardiovascular Finding.
Sharma, Jyoti; Rathnayaka, Nuvan; Green, Charles; Moeller, F Gerard; Schmitz, Joy M; Shoham, Daniel; Dougherty, Anne Hamilton
2016-01-01
Few studies have examined the effects of chronic cocaine use on the resting surface electrocardiogram (ECG) between exposures to cocaine. Researchers compared 12-lead ECGs from 97 treatment-seeking cocaine-dependent patients, with ECG parameters from 8,513 non-cocaine-using control patients from the Atherosclerosis Risk in Communities study. After matching and adjusting for relevant covariates, cocaine use demonstrated large and statistically reliable effects on early repolarization, bradycardia, severe bradycardia, and heart rate. Current cocaine dependence corresponds to an increased odds of demonstrating early repolarization by a factor of 4.92 and increased odds of bradycardia and severe bradycardia by factors 3.02 and 5.11, respectively. This study demonstrates the novel finding that long-lasting effects of cocaine use on both the cardiac conduction and the autonomic nervous system pose a risk of adverse cardiovascular events between episodes of cocaine use, and that bradycardia is a marker of chronic cocaine use.
Wearable ECG Based on Impulse-Radio-Type Human Body Communication.
Wang, Jianqing; Fujiwara, Takuya; Kato, Taku; Anzai, Daisuke
2016-09-01
Human body communication (HBC) provides a promising physical layer for wireless body area networks (BANs) in healthcare and medical applications, because of its low propagation loss and high security characteristics. In this study, we have developed a wearable electrocardiogram (ECG) which employs impulse radio (IR)-type HBC technology for transmitting vital signals on the human body in a wearable BAN scenario. The HBC-based wearable ECG has two excellent features. First, the wideband performance of the IR scheme contributed to very low radiation power so that the transceiver is easy to satisfy the extremely weak radio laws, which does not need a license. This feature can provide big convenience in the use and spread of the wearable ECG. Second, the realization of common use of sensing and transmitting electrodes based on time sharing and capacitive coupling largely simplified the HBC-based ECG structure and contributed to its miniaturization. To verify the validity of the HBC-based ECG, we evaluated its communication performance and ECG acquisition performance. The measured bit error rate, smaller than 10 -3 at 1.25 Mb/s, showed a good physical layer communication performance, and the acquired ECG waveform and various heart-rate variability parameters in time and frequency domains exhibited good agreement with a commercially available radio-frequency ECG and a Holter ECG. These results sufficiently showed the validity and feasibility of the HBC-based ECG for healthcare applications. This should be the first time to have realized a real-time ECG transmission by using the HBC technology.
The value of the 12-lead electrocardiogram in localizing the scar in non-ischaemic cardiomyopathy.
Oloriz, Teresa; Wellens, Hein J J; Santagostino, Giulia; Trevisi, Nicola; Silberbauer, John; Peretto, Giovanni; Maccabelli, Giuseppe; Della Bella, Paolo
2016-12-01
Patients with non-ischaemic cardiomyopathy (NICM) and ventricular tachycardia can be categorized as anteroseptal (AS) or inferolateral (IL) scar sub-types based on imaging and voltage mapping studies. The aim of this study was to correlate the baseline electrocardiogram (ECG) with endo-epicardial voltage maps created during ablation procedures and identify the ECG characteristics that may help to distinguish the scar as AS or IL. We assessed 108 baseline ECGs; 72 patients fulfilled criteria for dilated cardiomyopathy whereas 36 showed minimal structural abnormalities. Based on the unipolar low-voltage distribution, the scar pattern was classified as predominantly AS (n = 59) or IL (n = 49). Three ECG criteria (PR interval < 170 ms or QRS voltage in inferior leads <0.6 mV or a lateral q wave) resulted in 92% sensitivity and 90% specificity for predicting an IL pattern in patients with preserved ejection fraction (EF). The four-step algorithm for dilated cardiomyopathy included a paced ventricular rhythm or PR > 230 ms or QRS > 170 ms or an r ≤ 0.3 mV in V3 having 92 and 81% of sensitivity and specificity, respectively, in predicting AS scar pattern. A significant negative correlation was found between the extension of the endocardial unipolar low voltage area and left ventricular EF (r s = -0.719, P < 0.001). The extent of endocardial AS unipolar low voltage was correlated with PR interval and QRS duration (r s = 0.583 and r s = 0.680, P < 0.001, respectively) and the IL epicardial unipolar low voltage with the mean voltage of the limb leads (r s = -0.639, P < 0.001). Baseline ECG features are well correlated with the distribution of unipolar voltage abnormalities in NICM and may help to predict the location of scar in this population. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Lee, Yvonne Yin Leng; Jelinek, Herbert F; McLachlan, Craig S
2017-01-01
A positive correlation between ECG derived QRS duration and heart rate variability (HRV) parameters had previously been reported in young healthy adults. We note this study used a narrow QRS duration range, and did not adjust for systolic blood pressure. Our aims are to investigate associations between systolic blood pressure (SBP), QRS duration and HRV in a rural aging population. A retrospective cross sectional population was obtained from the CSU Diabetes Screening Research Initiative data base where 200 participants had no diabetes or pre-diabetes. SBP data were matched with ECG derived QRS duration and HRV parameters. HRV parameters were calculated from R-R intervals. Resting 12-lead electrocardiograms were obtained from each subject using a Welch Allyn PC-Based ECG system. Pearson correlation analysis revealed no statistically significant associations between HRV parameters and QRS duration. No significant mean differences in HRV parameter subgroups across defined QRS cut-offs were found. SBP > 146 mmHg was associated with increasing QRS durations, however this association disappeared once models were adjusted for age and gender. SBP was also significantly associated with a number of HRV parameters using Pearson correlation analysis, including high frequency (HF) ( p < 0.05), HFln ( p < 0.02), RMSDD ( p < 0.02) and non-linear parameters; ApEN ( p < 0.001) were negatively correlated with increasing SBP while the low frequency to high frequency ratio (LF/HF) increased with increasing SBP ( p < 0.03). Our results do not support associations between ECG derived R-R derived HRV parameters and QRS duration in aging populations. We suggest that ventricular conduction as determined by QRS duration is independent of variations in SA-node heart rate variability.
EMG (Electromyography) (For Parents)
... topic for: Parents Kids Teens ECG (Electrocardiogram) Muscular Dystrophy Bones, Muscles, and Joints EEG (Electroencephalogram) Getting an EKG (Video) Medical Tests and Procedures (Video Landing Page) EKG (Video) Medical Tests: What to Expect ... About Us Contact Us Partners Editorial ...
Zarzoso, Vicente; Latcu, Decebal G; Hidalgo-Muñoz, Antonio R; Meo, Marianna; Meste, Olivier; Popescu, Irina; Saoudi, Nadir
2016-12-01
Catheter ablation (CA) of persistent atrial fibrillation (AF) is challenging, and reported results are capable of improvement. A better patient selection for the procedure could enhance its success rate while avoiding the risks associated with ablation, especially for patients with low odds of favorable outcome. CA outcome can be predicted non-invasively by atrial fibrillatory wave (f-wave) amplitude, but previous works focused mostly on manual measures in single electrocardiogram (ECG) leads only. To assess the long-term prediction ability of f-wave amplitude when computed in multiple ECG leads. Sixty-two patients with persistent AF (52 men; mean age 61.5±10.4years) referred for CA were enrolled. A standard 1-minute 12-lead ECG was acquired before the ablation procedure for each patient. F-wave amplitudes in different ECG leads were computed by a non-invasive signal processing algorithm, and combined into a mutivariate prediction model based on logistic regression. During an average follow-up of 13.9±8.3months, 47 patients had no AF recurrence after ablation. A lead selection approach relying on the Wald index pointed to I, V1, V2 and V5 as the most relevant ECG leads to predict jointly CA outcome using f-wave amplitudes, reaching an area under the curve of 0.854, and improving on single-lead amplitude-based predictors. Analysing the f-wave amplitude in several ECG leads simultaneously can significantly improve CA long-term outcome prediction in persistent AF compared with predictors based on single-lead measures. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Vanninen, Sari U M; Nikus, Kjell; Aalto-Setälä, Katriina
2017-09-01
The cardiac sodium channel SCN5A regulates atrioventricular and ventricular depolarization as well as cardiac conduction. Patients with cardiac electrical abnormalities have an increased risk of sudden cardiac death (SCD) and cardio-embolic stroke. Optimal management of cardiac disease includes the understanding of association between the causative mutations and the clinical phenotype. A 12-lead electrocardiogram (ECG) is an easy and inexpensive tool for finding risk patients. A blood sample for DNA extraction was obtained in a Finnish family with 43 members; systematic 12-lead ECG analysis was performed in 13 of the family members carrying an SCN5A D1275N mutation. Conduction defects and supraventricular arrhythmias, including atrial fibrillation/flutter, atrioventricular nodal re-entry tachycardia (AVNRT) and junctional rhythm were searched for. Five (38%) mutation carriers had fascicular or bundle branch block, 10 had atrial arrhythmias; no ventricular arrhythmias were found. Notching of the R- and S waves - including initial QRS fragmentation - and prolonged S-wave upstroke were present in all the affected family members. Notably, four (31%) affected family members had a stroke before the age of 31 and two experienced premature death. A 12-lead ECG can be used to predict arrhythmias in SCN5A D1275N mutation carriers. Key messages The 12-lead ECG may reveal cardiac abnormalities even before clinical symptoms occur. Specific ECG findings - initial QRS fragmentation, prolonged S-wave upstroke as well as supraventricular arrhythmias - were frequently encountered in all SCN5A D1257N mutation carriers. ECG follow-up is recommended for all SCN5A D1275N mutation carriers.
The differences in electrocardiogram interpretation in top-level athletes.
Jakubiak, Agnieszka A; Burkhard-Jagodzińska, Krystyna; Król, Wojciech; Konopka, Marcin; Bursa, Dominik; Sitkowski, Dariusz; Kuch, Marek; Braksator, Wojciech
2017-01-01
The Ministry of Health in Poland recommends electrocardiogram (ECG)-based cardiovascular screening in athletes, but so far there has been a lack of guidelines on preparticipation assessment. We compared different criteria of ECG screening assessment in a group of top-level athletes. The aims were to evaluate the prevalence of ECG changes in athletes that necessitate further cardiological work-up according to three criteria in various age groups as well as to identify factors determining the occurrence of changes related and unrelated to the training. 262 high-dynamic, high-static Polish athletes (rowers, cyclists, canoeists) were divided into two age categories: young (≤ 18 years of age; n = 177, mean age 16.9 ± 0.8; 15-18 years) and elite (> 18 years of age; n = 85, mean age 22.9 ± 3.4; 19-34 years). All sports persons had a 12-lead ECG performed and evaluated according to 2010 European Society of Cardiology (ESC) recommendations, 2012 Seattle criteria, and 2014 Refined criteria. The Refined criteria reduced (p < 0.001) the number of training-unrelated ECG findings to 8.0% vs. 12.6% (Seattle criteria) and 30.5% (ESC recommendations). All three criteria revealed more training-related changes in the group of older athletes (76.5% vs. 55.9%, p = 0.001). Predictors that significantly (p < 0.005) affected the occurrence of adaptive changes were the age of the athlete, training duration (in years), and male gender. 1. The ESC criteria identified a group of athletes that was unacceptably large, as for the screening test, requiring verification with other methods (every fourth athlete). 2. The use of the Refined criteria helps to significantly reduce the frequency and necessity for additional tests. 3. The dependence of adaptive changes on training duration and athletes' age confirms the benign nature of those ECG findings.
Tobón, Diana P.; Jayaraman, Srinivasan
2017-01-01
The last few years has seen a proliferation of wearable electrocardiogram (ECG) devices in the market with applications in fitness tracking, patient monitoring, athletic performance assessment, stress and fatigue detection, and biometrics, to name a few. The majority of these applications rely on the computation of the heart rate (HR) and the so-called heart rate variability (HRV) index via time-, frequency-, or non-linear-domain approaches. Wearable/portable devices, however, are highly susceptible to artifacts, particularly those resultant from movement. These artifacts can hamper HR/HRV measurement, thus pose a serious threat to cardiac monitoring applications. While current solutions rely on ECG enhancement as a pre-processing step prior to HR/HRV calculation, existing artifact removal algorithms still perform poorly under extremely noisy scenarios. To overcome this limitation, we take an alternate approach and propose the use of a spectro-temporal ECG signal representation that we show separates cardiac components from artifacts. More specifically, by quantifying the rate-of-change of ECG spectral components over time, we show that heart rate estimates can be reliably obtained even in extremely noisy signals, thus bypassing the need for ECG enhancement. With such HR measurements in hands, we then propose a new noise-robust HRV index termed MD-HRV (modulation-domain HRV) computed as the standard deviation of the obtained HR values. Experiments with synthetic ECG signals corrupted at various different signal-to-noise levels, as well as recorded noisy signals show the proposed measure outperforming several HRV benchmark parameters computed post wavelet-based enhancement. These findings suggest that the proposed HR measures and derived MD-HRV metric are well-suited for ambulant cardiac monitoring applications, particularly those involving intense movement (e.g., elite athletic training). PMID:29255653
Live ECG readings using Google Glass in emergency situations.
Schaer, Roger; Salamin, Fanny; Jimenez Del Toro, Oscar Alfonso; Atzori, Manfredo; Muller, Henning; Widmer, Antoine
2015-01-01
Most sudden cardiac problems require rapid treatment to preserve life. In this regard, electrocardiograms (ECG) shown on vital parameter monitoring systems help medical staff to detect problems. In some situations, such monitoring systems may display information in a less than convenient way for medical staff. For example, vital parameters are displayed on large screens outside the field of view of a surgeon during cardiac surgery. This may lead to losing time and to mistakes when problems occur during cardiac operations. In this paper we present a novel approach to display vital parameters such as the second derivative of the ECG rhythm and heart rate close to the field of view of a surgeon using Google Glass. As a preliminary assessment, we run an experimental study to verify the possibility for medical staff to identify abnormal ECG rhythms from Google Glass. This study compares 6 ECG rhythms readings from a 13.3 inch laptop screen and from the prism of Google Glass. Seven medical residents in internal medicine participated in the study. The preliminary results show that there is no difference between identifying these 6 ECG rhythms from the laptop screen versus Google Glass. Both allow close to perfect identification of the 6 common ECG rhythms. This shows the potential of connected glasses such as Google Glass to be useful in selected medical applications.
A new mobile phone-based ECG monitoring system.
Iwamoto, Junichi; Yonezawa, Yoshiharu; Ogawa, Hiromichi Maki Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Allen W; Caldwell, W Morton
2007-01-01
We have developed a system for monitoring a patient's electrocardiogram (ECG) and movement during daily activities. The complete system is mounted on chest electrodes and continuously samples the ECG and three axis accelerations. When the patient feels a heart discomfort, he or she pushes the data transmission switch on the recording system and the system sends the recorded ECG waveforms and three axis accelerations of the two prior minutes, and for two minutes after the switch is pressed. The data goes directly to a hospital server computer via a 2.4 GHz low power mobile phone. These data are stored on a server computer and downloaded to the physician's Java mobile phone. The physician can display the data on the phone's liquid crystal display.
Chaos control applied to cardiac rhythms represented by ECG signals
NASA Astrophysics Data System (ADS)
Borem Ferreira, Bianca; Amorim Savi, Marcelo; Souza de Paula, Aline
2014-10-01
The control of irregular or chaotic heartbeats is a key issue in cardiology. In this regard, chaos control techniques represent a good alternative since they suggest treatments different from those traditionally used. This paper deals with the application of the extended time-delayed feedback control method to stabilize pathological chaotic heart rhythms. Electrocardiogram (ECG) signals are employed to represent the cardiovascular behavior. A mathematical model is employed to generate ECG signals using three modified Van der Pol oscillators connected with time delay couplings. This model provides results that qualitatively capture the general behavior of the heart. Controlled ECG signals show the ability of the strategy either to control or to suppress the chaotic heart dynamics generating less-critical behaviors.
Rodriguez-Fernandez, Rodrigo; Infante, Oscar; Perez-Grovas, Héctor; Hernandez, Erika; Ruiz-Palacios, Patricia; Franco, Martha; Lerma, Claudia
2012-06-01
This study evaluated the usefulness of the three-dimensional representation of electrocardiogram traces (3DECG) to reveal acute and gradual changes during a full session of hemodiafiltration (HDF) in end-stage renal disease (ESRD) patients. Fifteen ESRD patients were included (six men, nine women, age 46 ± 19 years old). Serum electrolytes, blood pressure, heart rate, and blood urea nitrogen (BUN) were measured before and after HDF. Continuous electrocardiograms (ECGs) obtained by Holter monitoring during HDF were used to produce the 3DECG. Several major disturbances were identified by 3DECG images: increase in QRS amplitude (47%), decrease in T-wave amplitude (33%), increase in heart rate (33%), and occurrence of arrhythmia (53%). Different arrhythmia types were often concurrent and included isolated supraventricular premature beats (N = 5), atrial fibrillation or atrial bigeminy (N = 2), and isolated premature ventricular beats (N = 6). Patients with decrease in T-wave amplitude had higher potassium and BUN (both before HDF and total removal) than those without decrease in T-wave amplitude (P < 0.05). Concurrent acute and gradual ECG changes during HDF are identified by the 3DECG, which could be useful as a preventive and prognostic method. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Research of the Heart Information Monitoring Robert Based on the 3G Wireless Communication Platform
NASA Astrophysics Data System (ADS)
Zhang, Fuli; Yang, Huazhe; Li, Gensong; Hong, Yang; Hu, Qingzhe
Electrocardiogram (ECG) of a person can be recorded and the diagnostic results can be displayed through touching the heart information monitoring Robert. In addition, the heart rate, phonocardiogram (PCG) and the dynamic three-dimensional echocardiography can also be displayed synchronously. Then the difficult ECG can be transmitted to the service center through 3G wireless communication center, followed by diagnosing the ECG by doctors and transmitting the feedback diagnostic results. I-lead ECG of the person can be recorded by the amplification circuit with high gain and low noise. Then, the heart rate and output phonocardiogram are displayed and the model of heart beat are started to trace through the recognition of R wave. Finally, the difficult ECG is transmitted to the service center via 3G communication chips. The displayed ECG is clear, and the stimulated heart beat is synchronous with that of the person. Furthermore, ECG received by the service center is in accordance with the one recorded by the Robert.
A Real-Time Cardiac Arrhythmia Classification System with Wearable Sensor Networks
Hu, Sheng; Wei, Hongxing; Chen, Youdong; Tan, Jindong
2012-01-01
Long term continuous monitoring of electrocardiogram (ECG) in a free living environment provides valuable information for prevention on the heart attack and other high risk diseases. This paper presents the design of a real-time wearable ECG monitoring system with associated cardiac arrhythmia classification algorithms. One of the striking advantages is that ECG analog front-end and on-node digital processing are designed to remove most of the noise and bias. In addition, the wearable sensor node is able to monitor the patient's ECG and motion signal in an unobstructive way. To realize the real-time medical analysis, the ECG is digitalized and transmitted to a smart phone via Bluetooth. On the smart phone, the ECG waveform is visualized and a novel layered hidden Markov model is seamlessly integrated to classify multiple cardiac arrhythmias in real time. Experimental results demonstrate that the clean and reliable ECG waveform can be captured in multiple stressed conditions and the real-time classification on cardiac arrhythmia is competent to other workbenches. PMID:23112746
Physician attitudes about prehospital 12-lead ECGs in chest pain patients.
Brainard, Andrew H; Froman, Philip; Alarcon, Maria E; Raynovich, Bill; Tandberg, Dan
2002-01-01
The prehospital 12-lead electrocardiogram (ECG) has become a standard of care. For the prehospital 12-lead ECG to be useful clinically, however, cardiologists and emergency physicians (EP) must view the test as useful. This study measured physician attitudes about the prehospital 12-lead ECG. This study tested the hypothesis that physicians had "no opinion" regarding the prehospital 12-lead ECG. An anonymous survey was conducted to measure EP and cardiologist attitudes toward prehospital 12-lead ECGs. Hypothesis tests against "no opinion" (VAS = 50 mm) were made with 95% confidence intervals (CIs), and intergroup comparisons were made with the Student's t-test. Seventy-one of 87 (81.6%) surveys were returned. Twenty-five (67.6%) cardiologists responded and 45 (90%) EPs responded. Both groups of physicians viewed prehospital 12-lead ECGs as beneficial (mean = 69 mm; 95% CI = 65-74 mm). All physicians perceived that ECGs positively influence preparation of staff (mean = 63 mm; 95% CI = 60-72 mm) and that ECGs transmitted to hospitals would be beneficial (mean = 66 mm; 95% CI = 60-72 mm). Cardiologists had more favorable opinions than did EPs. The ability of paramedics to interpret ECGs was not seen as important (mean = 50 mm; 95% CI = 43-56 mm). The justifiable increase in field time was perceived to be 3.2 minutes (95% CI = 2.7-3.8 minutes), with 23 (32.8%) preferring that it be done on scene, 46 (65.7%) during transport, and one (1.4%) not at all. Prehospital 12-lead ECGs generally are perceived as worthwhile by cardiologists and EPs. Cardiologists have a higher opinion of the value and utility of field ECGs. Since the reduction in mortality from the 12-lead ECG is small, it is likely that positive physician attitudes are attributable to other factors.
ECG interpretation skills of South African Emergency Medicine residents
Wallis, Lee; Maritz, David
2010-01-01
Background The use and interpretation of electrocardiograms (ECGs) are widely accepted as an essential core skill in Emergency Medicine. It is imperative that emergency physicians are expert in ECG interpretation when they exit their training programme. Aim It is unknown whether South African Emergency Medicine trainees are getting the necessary skills in ECG interpretation during the training programme. Currently there are no clear criteria to assess emergency physicians’ competency in ECG interpretation in South Africa. Methods A prospective cross-sectional study of Emergency Medicine residents and recently qualified emergency physicians was conducted between August 2008 and February 2009 using a focused questionnaire. Results At the time of the study, there were 55 eligible trainees in South Africa. A total of 55 assessments were distributed; 50 were returned (91%) and 49 were fully completed (89%). In this study, we found the overall average score of ECG interpretation was 46.4% [95% confidence interval (CI) 41.5–51.2%]. The junior group had an overall average of 42.2% (95% CI 36.9–47.5%), whereas the senior group managed 52.5% (95% CI 43.4–61.5%). Conclusion In this prospective cross-sectional study of Emergency Medicine residents and recently qualified emergency physicians, we found that there was improvement in the interpretation of ECGs with increased seniority. There exists, however, a low level of accuracy for many of the critical ECG diagnoses. The average score of 46.4% obtained in this study is lower than the scores obtained by other international studies from countries where Emergency Medicine is a well-established speciality. PMID:21373298
Ichihashi, Taku; Ito, Tsuyoshi; Murai, Shunsuke; Ikehara, Noriyuki; Fujita, Hiroshi; Suda, Hisao; Ohte, Nobuyuki
2016-09-01
A 58-year-old man was referred to our hospital because of chest pain. The 12-lead electrocardiogram (ECG) revealed ST-segment elevation in II, III, and a Vf with advanced heart block. Transthoracic echocardiography demonstrated aortic root dilatation at the sinus of Valsalva, moderate aortic regurgitation, and decreased wall motion in the inferior part of the left ventricle. Non-ECG-gated enhanced computed tomography (CT) did not reveal an aortic dissection. The patient underwent emergent coronary angiography, which revealed a severely narrowed ostium of the right coronary artery (RCA). Percutaneous coronary intervention (PCI) was performed under intravascular ultrasound (IVUS) guidance. IVUS images demonstrated an intimal flap extending from the aortic wall to the proximal RCA, suggesting that a periaortic hematoma in the false lumen compressed the ostium of the RCA, leading to acute myocardial infarction. To recover hemodynamic stability, the RCA ostium was stented. Subsequent ECG-gated enhanced CT clearly depicted the entry point and extension of the dissection localized within the sinus of Valsalva. The dissection likely involved the left main coronary artery and an emergent Bentall procedure was performed. Intraoperative findings confirmed an intimal tear and extension of the dissection. Thus, ECG-gated CT can clearly depict the entry site and extension of a dissection occurring in the localized area that cannot be detected by conventional CT.
Yang, Xianglin; Gu, Jiaojiao; Yan, Hong; Xu, Zhi; Ren, Bing; Yang, Yaming; Yang, Xiaodong; Chen, Qi; Tan, Shaohua
2014-01-01
We used bibliometric analysis methodology in the expanded Science Citation Index to identify highly-cited electrocardiogram (ECG)-related articles with total citations (TC2012) exceeding 100 from the publication year to 2012. Web of Science search tools were used to identify the highly-cited articles. The aspects analyzed for highly cited publications included effect of time on citation analysis, journals and Web of Science categories, number of authors per publication, originating institutions and countries, total citation and total citation per year life cycles of articles (C2012) and research hotspots. Results showed that a total of 467 electrocardiogram-related publications were regarded as the highly-cited publications. TC2012 ranged from 101 to 2879, with 215 as the average number of citations. No highly-cited publications have emerged yet during the first two years of the present 2010 Decade. All 11 countries and institutions originating highly-cited ECG-related publications were developed countries, USA in 9 of them. Four subject categories were identified as hotspots by total citations TC2012 and C2012: atrial fibrillation, long QT syndrome, angina and myocardial infarction, and risk factor analysis and health evaluation. Copyright © 2014 Elsevier Inc. All rights reserved.
Using ordinal partition transition networks to analyze ECG data
NASA Astrophysics Data System (ADS)
Kulp, Christopher W.; Chobot, Jeremy M.; Freitas, Helena R.; Sprechini, Gene D.
2016-07-01
Electrocardiogram (ECG) data from patients with a variety of heart conditions are studied using ordinal pattern partition networks. The ordinal pattern partition networks are formed from the ECG time series by symbolizing the data into ordinal patterns. The ordinal patterns form the nodes of the network and edges are defined through the time ordering of the ordinal patterns in the symbolized time series. A network measure, called the mean degree, is computed from each time series-generated network. In addition, the entropy and number of non-occurring ordinal patterns (NFP) is computed for each series. The distribution of mean degrees, entropies, and NFPs for each heart condition studied is compared. A statistically significant difference between healthy patients and several groups of unhealthy patients with varying heart conditions is found for the distributions of the mean degrees, unlike for any of the distributions of the entropies or NFPs.
The pre-operative electrocardiogram: an assessment.
Paterson, K R; Caskie, J P; Galloway, D J; McArthur, K; McWhinnie, D L
1983-04-01
Electrocardiography is of limited value in pre-operative screening for cardiac disease. A short questionnaire has been shown to be helpful in assessing cardiac status and could permit a 30% reduction in the number of pre-operative ECGs performed.
Association between obesity and ECG variables in children and adolescents: A cross-sectional study.
Sun, Guo-Zhe; Li, Yang; Zhou, Xing-Hu; Guo, Xiao-Fan; Zhang, Xin-Gang; Zheng, Li-Qiang; Li, Yuan; Jiao, Yun-DI; Sun, Ying-Xian
2013-12-01
Obesity exhibits a wide variety of electrocardiogram (ECG) abnormalities in adults, which often lead to cardiovascular events. However, there is currently no evidence of an association between obesity and ECG variables in children and adolescents. The present study aimed to explore the associations between obesity and ECG intervals and axes in children and adolescents. A cross-sectional observational study of 5,556 students aged 5-18 years was performed. Anthropometric data, blood pressure and standard 12-lead ECGs were collected for each participant. ECG variables were measured manually based on the temporal alignment of simultaneous 12 leads using a CV200 ECG Work Station. Overweight and obese groups demonstrated significantly longer PR intervals, wider QRS durations and leftward shifts of frontal P-wave, QRS and T-wave axes, while the obese group also demonstrated significantly higher heart rates, compared with normal weight groups within normotensive or hypertensive subjects (P<0.05). Abdominal obesity was also associated with longer PR intervals, wider QRS duration and a leftward shift of frontal ECG axes compared with normal waist circumference (WC) within normotensive or hypertensive subjects (P<0.05). Gender was a possible factor affecting the ECG variables. Furthermore, the ECG variables, including PR interval, QRS duration and frontal P-wave, QRS and T-wave axes, were significantly linearly correlated with body mass index, WC and waist-to-height ratio adjusted for age, gender, ethnicity and blood pressure. However, there was no significant association between obesity and the corrected QT interval (P>0.05). The results of the current study indicate that in children and adolescents, general and abdominal obesity is associated with longer PR intervals, wider QRS duration and a leftward shift of frontal P-wave, QRS and T-wave axes, independent of age, gender, ethnicity and blood pressure.
Robust and Accurate Anomaly Detection in ECG Artifacts Using Time Series Motif Discovery
Sivaraks, Haemwaan
2015-01-01
Electrocardiogram (ECG) anomaly detection is an important technique for detecting dissimilar heartbeats which helps identify abnormal ECGs before the diagnosis process. Currently available ECG anomaly detection methods, ranging from academic research to commercial ECG machines, still suffer from a high false alarm rate because these methods are not able to differentiate ECG artifacts from real ECG signal, especially, in ECG artifacts that are similar to ECG signals in terms of shape and/or frequency. The problem leads to high vigilance for physicians and misinterpretation risk for nonspecialists. Therefore, this work proposes a novel anomaly detection technique that is highly robust and accurate in the presence of ECG artifacts which can effectively reduce the false alarm rate. Expert knowledge from cardiologists and motif discovery technique is utilized in our design. In addition, every step of the algorithm conforms to the interpretation of cardiologists. Our method can be utilized to both single-lead ECGs and multilead ECGs. Our experiment results on real ECG datasets are interpreted and evaluated by cardiologists. Our proposed algorithm can mostly achieve 100% of accuracy on detection (AoD), sensitivity, specificity, and positive predictive value with 0% false alarm rate. The results demonstrate that our proposed method is highly accurate and robust to artifacts, compared with competitive anomaly detection methods. PMID:25688284
Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis
NASA Astrophysics Data System (ADS)
Kachenoura, A.; Porée, F.; Hernández, A. I.; Carrault, G.
2008-12-01
Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs) are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG) from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA). The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.
Issues in implementing a knowledge-based ECG analyzer for personal mobile health monitoring.
Goh, K W; Kim, E; Lavanya, J; Kim, Y; Soh, C B
2006-01-01
Advances in sensor technology, personal mobile devices, and wireless broadband communications are enabling the development of an integrated personal mobile health monitoring system that can provide patients with a useful tool to assess their own health and manage their personal health information anytime and anywhere. Personal mobile devices, such as PDAs and mobile phones, are becoming more powerful integrated information management tools and play a major role in many people's lives. We focus on designing a health-monitoring system for people who suffer from cardiac arrhythmias. We have developed computer simulation models to evaluate the performance of appropriate electrocardiogram (ECG) analysis techniques that can be implemented on personal mobile devices. This paper describes an ECG analyzer to perform ECG beat and episode detection and classification. We have obtained promising preliminary results from our study. Also, we discuss several key considerations when implementing a mobile health monitoring solution. The mobile ECG analyzer would become a front-end patient health data acquisition module, which is connected to the Personal Health Information Management System (PHIMS) for data repository.
Person identification in irregular cardiac conditions using electrocardiogram signals.
Sidek, Khairul Azami; Khalil, Ibrahim
2011-01-01
This paper presents a person identification mechanism in irregular cardiac conditions using ECG signals. A total of 30 subjects were used in the study from three different public ECG databases containing various abnormal heart conditions from the Paroxysmal Atrial Fibrillation Predicition Challenge database (AFPDB), MIT-BIH Supraventricular Arrthymia database (SVDB) and T-Wave Alternans Challenge database (TWADB). Cross correlation (CC) was used as the biometric matching algorithm with defined threshold values to evaluate the performance. In order to measure the efficiency of this simple yet effective matching algorithm, two biometric performance metrics were used which are false acceptance rate (FAR) and false reject rate (FRR). Our experimentation results suggest that ECG based biometric identification with irregular cardiac condition gives a higher recognition rate of different ECG signals when tested for three different abnormal cardiac databases yielding false acceptance rate (FAR) of 2%, 3% and 2% and false reject rate (FRR) of 1%, 2% and 0% for AFPDB, SVDB and TWADB respectively. These results also indicate the existence of salient biometric characteristics in the ECG morphology within the QRS complex that tends to differentiate individuals.
Grid mapping: a novel method of signal quality evaluation on a single lead electrocardiogram.
Li, Yanjun; Tang, Xiaoying
2017-12-01
Diagnosis of long-term electrocardiogram (ECG) calls for automatic and accurate methods of ECG signal quality estimation, not only to lighten the burden of the doctors but also to avoid misdiagnoses. In this paper, a novel waveform-based method of phase-space reconstruction for signal quality estimation on a single lead ECG was proposed by projecting the amplitude of the ECG and its first order difference into grid cells. The waveform of a single lead ECG was divided into non-overlapping episodes (T s = 10, 20, 30 s), and the number of grids in both the width and the height of each map are in the range [20, 100] (N X = N Y = 20, 30, 40, … 90, 100). The blank pane ratio (BPR) and the entropy were calculated from the distribution of ECG sampling points which were projected into the grid cells. Signal Quality Indices (SQI) bSQI and eSQI were calculated according to the BPR and the entropy, respectively. The MIT-BIH Noise Stress Test Database was used to test the performance of bSQI and eSQI on ECG signal quality estimation. The signal-to-noise ratio (SNR) during the noisy segments of the ECG records in the database is 24, 18, 12, 6, 0 and - 6 dB, respectively. For the SQI quantitative analysis, the records were divided into three groups: good quality group (24, 18 dB), moderate group (12, 6 dB) and bad quality group (0, - 6 dB). The classification among good quality group, moderate quality group and bad quality group were made by linear support-vector machine with the combination of the BPR, the entropy, the bSQI and the eSQI. The classification accuracy was 82.4% and the Cohen's Kappa coefficient was 0.74 on a scale of N X = 40 and T s = 20 s. In conclusion, the novel grid mapping offers an intuitive and simple approach to achieving signal quality estimation on a single lead ECG.
Viability of a Bioelectrical Signal Acquisition System Energized by Cellphone with NFC.
Kay, Marcel Seiji; Iaione, Fábio
2015-01-01
Currently, smartphones are used in various systems in the medical field due to the presence of various features, notably Near Field Communication (NFC). NFC utilizes communication technology and an energy supply based on electromagnetic induction. One of the most common medical tests is the electrocardiogram (ECG), through which various heart diseases can be diagnosed. The objective of this study is to evaluate the feasibility of providing power to a bioelectrical signal acquisition module using a mobile phone with NFC. After testing it was indicated that it is possible to construct a passive module to acquire ECG signals using NFC mobile phone.
Electrocardiographic Biomarkers for Detection of Drug-Induced Late Sodium Current Block
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vicente, Jose; Johannesen, Lars; Hosseini, Meisam
Drugs that prolong the heart rate corrected QT interval (QTc) on the electrocardiogram (ECG) by blocking the hERG potassium channel and also block inward currents (late sodium or L-type calcium) are not associated with torsade de pointes (e.g. ranolazine and verapamil). Furthermore, identifying ECG signs of late sodium current block could aid in the determination of proarrhythmic risk for new drugs. A new cardiac safety paradigm for drug development (the "CiPA" initiative) will involve the preclinical assessment of multiple human cardiac ion channels and ECG biomarkers are needed to determine if there are unexpected ion channel effects in humans.
Electrocardiographic Biomarkers for Detection of Drug-Induced Late Sodium Current Block
Vicente, Jose; Johannesen, Lars; Hosseini, Meisam; ...
2016-12-30
Drugs that prolong the heart rate corrected QT interval (QTc) on the electrocardiogram (ECG) by blocking the hERG potassium channel and also block inward currents (late sodium or L-type calcium) are not associated with torsade de pointes (e.g. ranolazine and verapamil). Furthermore, identifying ECG signs of late sodium current block could aid in the determination of proarrhythmic risk for new drugs. A new cardiac safety paradigm for drug development (the "CiPA" initiative) will involve the preclinical assessment of multiple human cardiac ion channels and ECG biomarkers are needed to determine if there are unexpected ion channel effects in humans.
Decomposition of ECG by linear filtering.
Murthy, I S; Niranjan, U C
1992-01-01
A simple method is developed for the delineation of a given electrocardiogram (ECG) signal into its component waves. The properties of discrete cosine transform (DCT) are exploited for the purpose. The transformed signal is convolved with appropriate filters and the component waves are obtained by computing the inverse transform (IDCT) of the filtered signals. The filters are derived from the time signal itself. Analysis of continuous strips of ECG signals with various arrhythmias showed that the performance of the method is satisfactory both qualitatively and quantitatively. The small amplitude P wave usually had a high percentage rms difference (PRD) compared to the other large component waves.
Object-oriented analysis and design of an ECG storage and retrieval system integrated with an HIS.
Wang, C; Ohe, K; Sakurai, T; Nagase, T; Kaihara, S
1996-03-01
For a hospital information system, object-oriented methodology plays an increasingly important role, especially for the management of digitized data, e.g., the electrocardiogram, electroencephalogram, electromyogram, spirogram, X-ray, CT and histopathological images, which are not yet computerized in most hospitals. As a first step in an object-oriented approach to hospital information management and storing medical data in an object-oriented database, we connected electrocardiographs to a hospital network and established the integration of ECG storage and retrieval systems with a hospital information system. In this paper, the object-oriented analysis and design of the ECG storage and retrieval systems is reported.
Identification of QRS complex in non-stationary electrocardiogram of sick infants.
Kota, S; Swisher, C B; Al-Shargabi, T; Andescavage, N; du Plessis, A; Govindan, R B
2017-08-01
Due to the high-frequency of routine interventions in an intensive care setting, electrocardiogram (ECG) recordings from sick infants are highly non-stationary, with recurrent changes in the baseline, alterations in the morphology of the waveform, and attenuations of the signal strength. Current methods lack reliability in identifying QRS complexes (a marker of individual cardiac cycles) in the non-stationary ECG. In the current study we address this problem by proposing a novel approach to QRS complex identification. Our approach employs lowpass filtering, half-wave rectification, and the use of instantaneous Hilbert phase to identify QRS complexes in the ECG. We demonstrate the application of this method using ECG recordings from eight preterm infants undergoing intensive care, as well as from 18 normal adult volunteers available via a public database. We compared our approach to the commonly used approaches including Pan and Tompkins (PT), gqrs, wavedet, and wqrs for identifying QRS complexes and then compared each with manually identified QRS complexes. For preterm infants, a comparison between the QRS complexes identified by our approach and those identified through manual annotations yielded sensitivity and positive predictive values of 99% and 99.91%, respectively. The comparison metrics for each method are as follows: PT (sensitivity: 84.49%, positive predictive value: 99.88%), gqrs (85.25%, 99.49%), wavedet (95.24%, 99.86%), and wqrs (96.99%, 96.55%). Thus, the sensitivity values of the four methods previously described, are lower than the sensitivity of the method we propose; however, the positive predictive values of these other approaches is comparable to those of our method, with the exception of the wqrs approach, which yielded a slightly lower value. For adult ECG, our approach yielded a sensitivity of 99.78%, whereas PT yielded 99.79%. The positive predictive value was 99.42% for both our approach as well as for PT. We propose a novel method for identifying QRS complexes that outperforms common currently available tools for non-stationary ECG data in infants. For stationary ECG our proposed approach and the PT approach perform equally well. The ECG acquired in a clinical environment may be prone to issues related to non-stationarity, especially in critically ill patients. The approach proposed in this report offers superior reliability in these scenarios. Copyright © 2017 Elsevier Ltd. All rights reserved.
A flexible skin patch for continuous physiological monitoring of mental disorders
NASA Astrophysics Data System (ADS)
Jang, Won Ick; Lee, Bong Kuk; Ryu, Jin Hwa; Baek, In-Bok; Yu, Han Young; Kim, Seunghwan
2017-10-01
In this study, we have newly developed a flexible adhesive skin patch of electrocardiogram (ECG) device for continuous physiological monitoring of mental disorders. In addition, this flexible patch did not cause any damage to the skin even after 24 hours attachment. We have also suggested the possibility of novel interconnection for copper film on polyimide and polydimethylsiloxane (PDMS) layers of the flexible patch. Self-align and soldering of IC chips such as resistor between metal pads on flexible skin patch have also successfully fabricated for 5 min at 180 °C in vacuum oven. Low temperature interconnection technology based on a Sn42/Bi58 solder was also developed for flexible ECG devices. As a result, we can monitor the mental health status through a comprehensive analysis of biological signals from flexible ECG devices.
Shuai, Wei; Wang, Xi-Xing; Hong, Kui; Peng, Qiang; Li, Ju-Xiang; Li, Ping; Chen, Jing; Cheng, Xiao-Shu; Su, Hai
2016-07-15
At present, the estimation of rest heart rate (HR) in atrial fibrillation (AF) is obtained by apical auscultation for 1min or on the surface electrocardiogram (ECG) by multiplying the number of RR intervals on the 10second recording by six. But the reasonability of 10second ECG recording is controversial. ECG was continuously recorded at rest for 60s to calculate the real rest HR (HR60s). Meanwhile, the first 10s and 30s ECG recordings were used for calculating HR10s (sixfold) and HR30s (twofold). The differences of HR10s or HR30s with the HR60s were compared. The patients were divided into three sub-groups on the HR60s <80, 80-100 and >100bpm. No significant difference among the mean HR10s, HR30s and HR60s was found. A positive correlation existed between HR10s and HR60s or HR30s and HR60s. Bland-Altman plot showed that the 95% reference limits were high as -11.0 to 16.0bpm for HR10s, but for HR30s these values were only -4.5 to 5.2bpm. Among the three subgroups with HR60s <80, 80-100 and >100bpm, the 95% reference limits with HR60s were -8.9 to 10.6, -10.5 to 14.0 and -11.3 to 21.7bpm for HR10s, but these values were -3.9 to 4.3, -4.1 to 4.6 and -5.3 to 6.7bpm for HR30s. As 10s ECG recording could not provide clinically accepted estimation HR, ECG should be recorded at least for 30s in the patients with AF. It is better to record ECG for 60s when the HR is rapid. Copyright © 2016. Published by Elsevier Ireland Ltd.
Singh, Omkar; Sunkaria, Ramesh Kumar
2017-12-01
This paper presents a novel technique to identify heartbeats in multimodal data using electrocardiogram (ECG) and arterial blood pressure (ABP) signals. Multiple physiological signals such as ECG, ABP, and Respiration are often recorded in parallel from the activity of heart. These signals generally possess related information as they are generated by the same physical system. The ECG and ABP correspond to the same phenomenon of contraction and relaxation activity of heart. Multiple signals acquired from various sensors are generally processed independently, thus discarding the information from other measurements. In the estimation of heart rate and heart rate variability, the R peaks are generally identified from ECG signal. Efficient detection of R-peaks in electrocardiogram (ECG) is a key component in the estimation of clinically relevant parameters from ECG. However, when the signal is severely affected by undesired artifacts, this becomes a challenging task. Sometimes in clinical environment, other physiological signals reflecting the cardiac activity such as ABP signal are also acquired simultaneously. Under the availability of such multimodal signals, the accuracy of R peak detection methods can be improved using sensor-fusion techniques. In the proposed method, the sample entropy (SampEn) is used as a metric for assessing the noise content in the physiological signal and the R peaks in ECG and the systolic peaks in ABP signals are fused together to enhance the efficiency of heartbeat detection. The proposed method was evaluated on the 100 records from the computing in cardiology challenge 2014 training data set. The performance parameters are: sensitivity (Se) and positive predictivity (PPV). The unimodal R peaks detector achieved: Se gross = 99.40%, PPV gross = 99.29%, Se average = 99.37%, PPV average = 99.29%. Similarly unimodal BP delineator achieved Se gross = 99.93%, PPV gross = 99.99%, Se average = 99.93%, PPV average = 99.99% whereas, the proposed multimodal beat detector achieved: Se gross = 99.65%, PPV gross = 99.91%, Se average = 99.68%, PPV average = 99.91%.
Saturation of the right-leg drive amplifier in low-voltage ECG monitors.
Freeman, Daniel K; Gatzke, Ronald D; Mallas, Georgios; Chen, Yu; Brouse, Chris J
2015-01-01
Electrocardiogram (ECG) monitoring is a critical tool in patient care, but its utility is often balanced with frustration from clinicians who are constantly distracted by false alarms. This has motivated the need to readdress the major factors that contribute to ECG noise with the goal of reducing false alarms. In this study, we describe a previously unreported phenomenon in which ECG noise can result from an unintended interaction between two systems: 1) the dc lead-off circuitry that is used to detect whether electrodes fall off the patient; and 2) the right-leg drive (RLD) system that is responsible for reducing ac common-mode noise that couples into the body. Using a circuit model to study this interaction, we found that in the presence of a dc lead-off system, even moderate increases in the right-leg skin-electrode resistance can cause the RLD amplifier to saturate. Such saturation can produce ECG noise because the RLD amplifier will no longer be capable of attenuating ac common-mode noise on the body. RLD saturation is particularly a problem for modern ECG monitors that use low-voltage supply levels. For example, for a 12-lead ECG and a 2 V power supply, saturation will occur when the right-leg electrode resistance reaches only 2 MΩ. We discuss several design solutions that can be used in low-voltage monitors to avoid RLD saturation.
Characterization of dry biopotential electrodes.
Xie, Li; Yang, Geng; Xu, Linlin; Seoane, Fernando; Chen, Qiang; Zheng, Lirong
2013-01-01
Driven by the increased interest in wearable long-term healthcare monitoring systems, varieties of dry electrodes are proposed based on different materials with different patterns and structures. Most of the studies reported in the literature focus on proposing new electrodes and comparing its performance with commercial electrodes. Few papers are about detailed comparison among different dry electrodes. In this paper, printed metal-plate electrodes, textile based electrodes, and spiked electrodes are for the first time evaluated and compared under the same experimental setup. The contact impedance and noise characterization are measured. The in-vivo electrocardiogram (ECG) measurement is applied to evaluate the overall performance of different electrodes. Textile electrodes and printed electrodes gain comparable high-quality ECG signals. The ECG signal obtained by spiked electrodes is noisier. However, a clear ECG envelope can be observed and the signal quality can be easily improved by backend signal processing. The features of each type of electrodes are analyzed and the suitable application scenario is addressed.
Noise-assisted data processing with empirical mode decomposition in biomedical signals.
Karagiannis, Alexandros; Constantinou, Philip
2011-01-01
In this paper, a methodology is described in order to investigate the performance of empirical mode decomposition (EMD) in biomedical signals, and especially in the case of electrocardiogram (ECG). Synthetic ECG signals corrupted with white Gaussian noise are employed and time series of various lengths are processed with EMD in order to extract the intrinsic mode functions (IMFs). A statistical significance test is implemented for the identification of IMFs with high-level noise components and their exclusion from denoising procedures. Simulation campaign results reveal that a decrease of processing time is accomplished with the introduction of preprocessing stage, prior to the application of EMD in biomedical time series. Furthermore, the variation in the number of IMFs according to the type of the preprocessing stage is studied as a function of SNR and time-series length. The application of the methodology in MIT-BIH ECG records is also presented in order to verify the findings in real ECG signals.
Genetic algorithm for the optimization of features and neural networks in ECG signals classification
NASA Astrophysics Data System (ADS)
Li, Hongqiang; Yuan, Danyang; Ma, Xiangdong; Cui, Dianyin; Cao, Lu
2017-01-01
Feature extraction and classification of electrocardiogram (ECG) signals are necessary for the automatic diagnosis of cardiac diseases. In this study, a novel method based on genetic algorithm-back propagation neural network (GA-BPNN) for classifying ECG signals with feature extraction using wavelet packet decomposition (WPD) is proposed. WPD combined with the statistical method is utilized to extract the effective features of ECG signals. The statistical features of the wavelet packet coefficients are calculated as the feature sets. GA is employed to decrease the dimensions of the feature sets and to optimize the weights and biases of the back propagation neural network (BPNN). Thereafter, the optimized BPNN classifier is applied to classify six types of ECG signals. In addition, an experimental platform is constructed for ECG signal acquisition to supply the ECG data for verifying the effectiveness of the proposed method. The GA-BPNN method with the MIT-BIH arrhythmia database achieved a dimension reduction of nearly 50% and produced good classification results with an accuracy of 97.78%. The experimental results based on the established acquisition platform indicated that the GA-BPNN method achieved a high classification accuracy of 99.33% and could be efficiently applied in the automatic identification of cardiac arrhythmias.
ECG authentication in post-exercise situation.
Dongsuk Sung; Jeehoon Kim; Myungjun Koh; Kwangsuk Park
2017-07-01
Human authentication based on electrocardiogram (ECG) has been a remarkable issue for recent ten years. This paper proposed an authentication technology with the ECG data recorded after the harsh exercise. 55 subjects voluntarily attended to this experiment. A stepper was used as an exercise equipment. The subjects are asked to do stepper for 5 minutes and their ECG signals are acquired before and after the exercise in rest, sitting posture. Linear discriminant analysis (LDA) was used for both feature extraction and classification. Even though, within the first 1 minute recording, the subject recognition accuracy was 59.64%, which is too low to utilize, after one minute the accuracy was higher than 90% and it increased up to 96.22% within 5 minutes, which is plausible to use in authentication circumstances. Therefore, we have concluded that ECG authentication techniques will be able to be used after 1 minute of catching breath.
A sub-nJ CMOS ECG classifier for wireless smart sensor.
Chollet, Paul; Pallas, Remi; Lahuec, Cyril; Arzel, Matthieu; Seguin, Fabrice
2017-07-01
Body area sensor networks hold the promise of more efficient and cheaper medical care services through the constant monitoring of physiological markers such as heart beats. Continuously transmitting the electrocardiogram (ECG) signal requires most of the wireless ECG sensor energy budget. This paper presents the analog implantation of a classifier for ECG signals that can be embedded onto a sensor. The classifier is a sparse neural associative memory. It is implemented using the ST 65 nm CMOS technology and requires only 234 pJ per classification while achieving a 93.6% classification accuracy. The energy requirement is 6 orders of magnitude lower than a digital accelerator that performs a similar task. The lifespan of the resulting sensor is 191 times as large as that of a sensor sending all the data.
A time-frequency approach for the analysis of normal and arrhythmia cardiac signals.
Mahmoud, Seedahmed S; Fang, Qiang; Davidović, Dragomir M; Cosic, Irena
2006-01-01
Previously, electrocardiogram (ECG) signals have been analyzed in either a time-indexed or spectral form. The reality, is that the ECG and all other biological signals belong to the family of multicomponent nonstationary signals. Due to this reason, the use of time-frequency analysis can be unavoidable for these signals. The Husimi and Wigner distributions are normally used in quantum mechanics for phase space representations of the wavefunction. In this paper, we introduce the Husimi distribution (HD) to analyze the normal and abnormal ECG signals in time-frequency domain. The abnormal cardiac signal was taken from a patient with supraventricular arrhythmia. Simulation results show that the HD has a good performance in the analysis of the ECG signals comparing with the Wigner-Ville distribution (WVD).
Fetal ECG Extraction From Maternal Body Surface Measurement Using Independent Component Analysis
2001-10-25
Ibaraki 305-0901, Japan Abstract – A method applying independent component analysis (ICA) to detect the electrocardiogram of a prenatal cattle foetus is...monitoring the health status of an unborn cattle foetus is indispensable in preventing natural abortion and premature birth [3]. One of the applicable...and Y. Honda, “ECG and Heart Rate Detection of Prenatal Cattle Foetus Using Adaptive Digital Filtering,” World Congress on Med. Phys.& Biomed. Eng., Chicago TU-CXH-75, pp. 1-4, 2000.
Novella, John; DeBiasi, Ralph M; Coplan, Neil L; Suri, Ranji; Keller, Seth
2014-01-01
Sudden cardiac death (SCD) as the first clinical manifestation of Wolff-Parkinson-White (WPW) syndrome is a well-documented, although rare occurrence. The incidence of SCD in patients with WPW ranges from 0% to 0.39% annually. Controversy exists regarding risk stratification for patients with preexcitation on surface electrocardiogram (ECG), particularly in those who are asymptomatic. This article focuses on the role of risk stratification using exercise and pharmacologic testing in patients with WPW pattern on ECG.
A mobile phone-based ECG monitoring system.
Iwamoto, Junichi; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Allen W; Caldwell, W Morton
2006-01-01
We have developed a telemedicine system for monitoring a patient's electrocardiogram during daily activities. The recording system consists of three ECG chest electrodes, a variable gain instrumentation amplifier, a low power 8-bit single-chip microcomputer, a 256 KB EEPROM and a 2.4 GHz low transmitting power mobile phone (PHS). The complete system is mounted on a single, lightweight, chest electrode array. When a heart discomfort is felt, the patient pushes the data transmission switch on the recording system. The system sends the recorded ECG waveforms of the two prior minutes and ECG waveforms of the two minutes after the switch is pressed, directly in the hospital server computer via the PHS. The server computer sends the data to the physician on call. The data is displayed on the doctor's Java mobile phone LCD (Liquid Crystal Display), so he or she can monitor the ECG regardless of their location. The developed ECG monitoring system is not only applicable to at-home patients, but should also be useful for monitoring hospital patients.
A system for intelligent home care ECG upload and priorisation.
D'Angelo, Lorenzo T; Tarita, Eugeniu; Zywietz, Tosja K; Lueth, Tim C
2010-01-01
In this contribution, a system for internet based, automated home care ECG upload and priorisation is presented for the first time. It unifies the advantages of existing telemonitoring ECG systems adding functionalities such as automated priorisation and usability for home care. Chronic cardiac diseases are a big group in the geriatric field. Most of them can be easily diagnosed with help of an electrocardiogram. A frequent or long-term ECG analysis allows early diagnosis of e.g. a cardiac infarction. Nevertheless, patients often aren't willing to visit a doctor for prophylactic purposes. Possible solutions of this problem are home care devices, which are used to investigate patients at home without the presence of a doctor on site. As the diffusion of such systems leads to a huge amount of data which has to be managed and evaluated, the presented approach focuses on an easy to use software for ECG upload from home, a web based management application and an algorithm for ECG preanalysis and priorisation.
Implementation of a wireless ECG acquisition SoC for IEEE 802.15.4 (ZigBee) applications.
Wang, Liang-Hung; Chen, Tsung-Yen; Lin, Kuang-Hao; Fang, Qiang; Lee, Shuenn-Yuh
2015-01-01
This paper presents a wireless biosignal acquisition system-on-a-chip (WBSA-SoC) specialized for electrocardiogram (ECG) monitoring. The proposed system consists of three subsystems, namely, 1) the ECG acquisition node, 2) the protocol for standard IEEE 802.15.4 ZigBee system, and 3) the RF transmitter circuits. The ZigBee protocol is adopted for wireless communication to achieve high integration, applicability, and portability. A fully integrated CMOS RF front end containing a quadrature voltage-controlled oscillator and a 2.4-GHz low-IF (i.e., zero-IF) transmitter is employed to transmit ECG signals through wireless communication. The low-power WBSA-SoC is implemented by the TSMC 0.18-μm standard CMOS process. An ARM-based displayer with FPGA demodulation and an RF receiver with analog-to-digital mixed-mode circuits are constructed as verification platform to demonstrate the wireless ECG acquisition system. Measurement results on the human body show that the proposed SoC can effectively acquire ECG signals.
Wong, Jim K; Lobato, Robert L; Pinesett, Andre; Maxwell, Bryan G; Mora-Mangano, Christina T; Perez, Marco V
2014-12-01
To test the hypothesis that including preoperative electrocardiogram (ECG) characteristics with clinical variables significantly improves the new-onset postoperative atrial fibrillation prediction model. Retrospective analysis. Single-center university hospital. Five hundred twenty-six patients, ≥ 18 years of age, who underwent coronary artery bypass grafting, aortic valve replacement, mitral valve replacement/repair, or a combination of valve surgery and coronary artery bypass grafting requiring cardiopulmonary bypass. Retrospective review of medical records. Baseline characteristics and cardiopulmonary bypass times were collected. Digitally-measured timing and voltages from preoperative electrocardiograms were extracted. Postoperative atrial fibrillation was defined as atrial fibrillation requiring therapeutic intervention. Two hundred eight (39.5%) patients developed postoperative atrial fibrillation. Clinical predictors were age, ejection fraction<55%, history of atrial fibrillation, history of cerebral vascular event, and valvular surgery. Three ECG parameters associated with postoperative atrial fibrillation were observed: Premature atrial contraction, p-wave index, and p-frontal axis. Adding electrocardiogram variables to the prediction model with only clinical predictors significantly improved the area under the receiver operating characteristic curve, from 0.71 to 0.78 (p<0.01). Overall net reclassification improvement was 0.059 (p = 0.09). Among those who developed postoperative atrial fibrillation, the net reclassification improvement was 0.063 (p = 0.03). Several p-wave characteristics are independently associated with postoperative atrial fibrillation. Addition of these parameters improves the postoperative atrial fibrillation prediction model. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Jung, Christian; Ferrari, Markus; Goebel, Bjoern; Figulla, Hans R
2009-08-21
The exercise electrocardiogram is a commonly used non-invasive method for detection of electrocardiogram (ECG) changes secondary to myocardial ischemia. Studies showed the importance of the patient's motivation to reach the estimated submaximal heart rate. The purpose of this study was to test whether the patient's motivation is dependent on the investigator's sex. We included 1170 patients (in-hospital patients and out-clinic patients; 63.5% male, 36.5% female) in this study. Stress test data (stationary bicycle with gradually increasing intensity) were collected retrospectively: patient's age, sex, maximal power stage, ECG-abnormalities, angina pectoris, and attending physician's sex. Male patients achieved a higher power stage than their female counterparts (126.5+/-47.7 W vs. 89.7+/-30.4 W). When male patients were supervised by a female doctor they reached higher maximum power stages (136.6+/-53.5 W vs. 121.6+/-43.3 W; p=0,001), more often the submaximal heart rate (47.9% vs. 38.3%; p=0.02) but complained less frequent about angina pectoris (5.6% vs. 17.3%). In contrast, none of these parameters was dependent on the attending physician's sex in female patients. The attending physician's sex influences the maximum exercise ability and the incidence of complaints during bicycle stress in male patients but not in females. We would speculate that men try to impress women with physical strength and try to dissimulate physical discomfort or pain. This could possibly influence the validity of such non-invasive methods with exercise dependent detection of myocardial ischemia.
Extended Kalman smoother with differential evolution technique for denoising of ECG signal.
Panigrahy, D; Sahu, P K
2016-09-01
Electrocardiogram (ECG) signal gives a lot of information on the physiology of heart. In reality, noise from various sources interfere with the ECG signal. To get the correct information on physiology of the heart, noise cancellation of the ECG signal is required. In this paper, the effectiveness of extended Kalman smoother (EKS) with the differential evolution (DE) technique for noise cancellation of the ECG signal is investigated. DE is used as an automatic parameter selection method for the selection of ten optimized components of the ECG signal, and those are used to create the ECG signal according to the real ECG signal. These parameters are used by the EKS for the development of the state equation and also for initialization of the parameters of EKS. EKS framework is used for denoising the ECG signal from the single channel. The effectiveness of proposed noise cancellation technique has been evaluated by adding white, colored Gaussian noise and real muscle artifact noise at different SNR to some visually clean ECG signals from the MIT-BIH arrhythmia database. The proposed noise cancellation technique of ECG signal shows better signal to noise ratio (SNR) improvement, lesser mean square error (MSE) and percent of distortion (PRD) compared to other well-known methods.
Near Field Communication-based telemonitoring with integrated ECG recordings.
Morak, J; Kumpusch, H; Hayn, D; Leitner, M; Scherr, D; Fruhwald, F M; Schreier, G
2011-01-01
Telemonitoring of vital signs is an established option in treatment of patients with chronic heart failure (CHF). In order to allow for early detection of atrial fibrillation (AF) which is highly prevalent in the CHF population telemonitoring programs should include electrocardiogram (ECG) signals. It was therefore the aim to extend our current home monitoring system based on mobile phones and Near Field Communication technology (NFC) to enable patients acquiring their ECG signals autonomously in an easy-to-use way. We prototypically developed a sensing device for the concurrent acquisition of blood pressure and ECG signals. The design of the device equipped with NFC technology and Bluetooth allowed for intuitive interaction with a mobile phone based patient terminal. This ECG monitoring system was evaluated in the course of a clinical pilot trial to assess the system's technical feasibility, usability and patient's adherence to twice daily usage. 21 patients (4f, 54 ± 14 years) suffering from CHF were included in the study and were asked to transmit two ECG recordings per day via the telemonitoring system autonomously over a monitoring period of seven days. One patient dropped out from the study. 211 data sets were transmitted over a cumulative monitoring period of 140 days (overall adherence rate 82.2%). 55% and 8% of the transmitted ECG signals were sufficient for ventricular and atrial rhythm assessment, respectively. Although ECG signal quality has to be improved for better AF detection the developed communication design of joining Bluetooth and NFC technology in our telemonitoring system allows for ambulatory ECG acquisition with high adherence rates and system usability in heart failure patients.
47 CFR 95.1117 - Types of communications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Types of communications. 95.1117 Section 95.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... care. Waveforms such as electrocardiograms (ECGs) are not considered video. (b) Operations that comply...
47 CFR 95.1117 - Types of communications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Types of communications. 95.1117 Section 95.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... care. Waveforms such as electrocardiograms (ECGs) are not considered video. (b) Operations that comply...
Development of a portable Linux-based ECG measurement and monitoring system.
Tan, Tan-Hsu; Chang, Ching-Su; Huang, Yung-Fa; Chen, Yung-Fu; Lee, Cheng
2011-08-01
This work presents a portable Linux-based electrocardiogram (ECG) signals measurement and monitoring system. The proposed system consists of an ECG front end and an embedded Linux platform (ELP). The ECG front end digitizes 12-lead ECG signals acquired from electrodes and then delivers them to the ELP via a universal serial bus (USB) interface for storage, signal processing, and graphic display. The proposed system can be installed anywhere (e.g., offices, homes, healthcare centers and ambulances) to allow people to self-monitor their health conditions at any time. The proposed system also enables remote diagnosis via Internet. Additionally, the system has a 7-in. interactive TFT-LCD touch screen that enables users to execute various functions, such as scaling a single-lead or multiple-lead ECG waveforms. The effectiveness of the proposed system was verified by using a commercial 12-lead ECG signal simulator and in vivo experiments. In addition to its portability, the proposed system is license-free as Linux, an open-source code, is utilized during software development. The cost-effectiveness of the system significantly enhances its practical application for personal healthcare.
Arduino-based noise robust online heart-rate detection.
Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda
2017-04-01
This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.
Smartphone ECG aids real time diagnosis of palpitations in the competitive college athlete.
Peritz, David C; Howard, Austin; Ciocca, Mario; Chung, Eugene H
2015-01-01
Rapidly detecting dangerous arrhythmias in a symptomatic athlete continues to be an elusive goal. The use of handheld smartphone electrocardiogram (ECG) monitors could represent a helpful tool connecting the athletic trainer to the cardiologist. Six college athletes presented to their athletic trainers complaining of palpitations during exercise. A single lead ECG was performed using the AliveCor Heart Monitor and sent wirelessly to the Team Cardiologist who confirmed an absence of dangerous arrhythmia. AliveCor monitoring has the potential to enhance evaluation of symptomatic athletes by allowing trainers and team physicians to make diagnosis in real-time and facilitate faster return to play. Copyright © 2015 Elsevier Inc. All rights reserved.
Bradycardia as a Marker of Chronic Cocaine Use: A Novel Cardiovascular Finding
Sharma, Jyoti; Rathnayaka, Nuvan; Green, Charles; Moeller, F. Gerard; Schmitz, Joy M.; Shoham, Daniel; Dougherty, Anne Hamilton
2014-01-01
Background Few studies have examined the effects of chronic cocaine use on the resting surface electrocardiogram (ECG) between exposures to cocaine. Methods 12-lead ECGs from 97 treatment-seeking cocaine-dependent subjects were compared to ECG parameters from 8513 non-cocaine-using control subjects from the Atherosclerosis Risk in Communities study. Results After matching and adjusting for relevant covariates, cocaine use demonstrated large and statistically reliable effects on early repolarization, bradycardia, severe bradycardia, and heart rate. Current cocaine dependence corresponds to an increased odds of demonstrating early repolarization by a factor of 4.92 and increased odds of bradycardia and severe bradycardia by factors 3.02 and 5.11, respectively. Conclusion This study demonstrates the novel finding that long-lasting effects of cocaine use on both the cardiac conduction and the autonomic nervous system pose a risk of adverse cardiovascular events between episodes of cocaine use, and that bradycardia is a marker of chronic cocaine use. PMID:24621090
Correlation between ECG changes and early left ventricular remodeling in preadolescent footballers.
Zdravkovic, M; Milovanovic, B; Hinic, S; Soldatovic, I; Durmic, T; Koracevic, G; Prijic, S; Markovic, O; Filipovic, B; Lovic, D
2017-03-01
The aim of this study was to assess the early electrocardiogram (ECG) changes induced by physical training in preadolescent elite footballers. This study included 94 preadolescent highly trained male footballers (FG) competing in Serbian Football League (minimum of 7 training hours/week) and 47 age-matched healthy male controls (less than 2 training hours/week) (CG). They were screened by ECG and echocardiography at a tertiary referral cardio center. Sokolow-Lyon index was used as a voltage electrocardiographic criterion for left ventricular hypertrophy diagnosis. Characteristic ECG intervals and voltage were compared and reference range was given for preadolescent footballers. Highly significant differences between FG and CG were registered in all ECG parameters: P-wave voltage (p < 0.001), S-wave (V1 or V2 lead) voltage (p < 0.001), R-wave (V5 and V6 lead) voltage (p < 0.001), ECG sum of S V 1-2 + R V 5-6 (p < 0.001), T-wave voltage (p < 0.001), QRS complex duration (p < 0.001), T-wave duration (p < 0.001), QTc interval duration (p < 0.001), and R/T ratio (p < 0.001). No differences were found in PQ interval duration between these two groups (p > 0.05). During 6-year follow-up period, there was no adverse cardiac event in these footballers. None of them expressed pathological ECG changes. Benign ECG changes are presented in the early stage of athlete's heart remodeling, but they are not related to pathological ECG changes and they should be regarded as ECG pattern of LV remodeling.
Lankveld, Theo; de Vos, Cees B; Limantoro, Ione; Zeemering, Stef; Dudink, Elton; Crijns, Harry J; Schotten, Ulrich
2016-05-01
Electrical cardioversion (ECV) is one of the rhythm control strategies in patients with persistent atrial fibrillation (AF). Unfortunately, recurrences of AF are common after ECV, which significantly limits the practical benefit of this treatment in patients with AF. The objectives of this study were to identify noninvasive complexity or frequency parameters obtained from the surface electrocardiogram (ECG) to predict sinus rhythm (SR) maintenance after ECV and to compare these ECG parameters with clinical predictors. We studied a wide variety of ECG-derived time- and frequency-domain AF complexity parameters in a prospective cohort of 502 patients with persistent AF referred for ECV. During 1-year follow-up, 161 patients (32%) maintained SR. The best clinical predictor of SR maintenance was antiarrhythmic drug (AAD) treatment. A model including clinical parameters predicted SR maintenance with a mean cross-validated area under the receiver operating characteristic curve (AUC) of 0.62 ± 0.05. The best single ECG parameter was the dominant frequency (DF) on lead V6. Combining several ECG parameters predicted SR maintenance with a mean AUC of 0.64 ± 0.06. Combining clinical and ECG parameters improved prediction to a mean AUC of 0.67 ± 0.05. Although the DF was affected by AAD treatment, excluding patients taking AADs did not significantly lower the predictive performance captured by the ECG. ECG-derived parameters predict SR maintenance during 1-year follow-up after ECV at least as good as known clinical predictors of rhythm outcome. The DF proved to be the most powerful ECG-derived predictor. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Computer-based rhythm diagnosis and its possible influence on nonexpert electrocardiogram readers.
Hakacova, Nina; Trägårdh-Johansson, Elin; Wagner, Galen S; Maynard, Charles; Pahlm, Olle
2012-01-01
Systems providing computer-based analysis of the resting electrocardiogram (ECG) seek to improve the quality of health care by providing accurate and timely automatic diagnosis of, for example, cardiac rhythm to clinicians. The accuracy of these diagnoses, however, remains questionable. We tested the hypothesis that (a) 2 independent automated ECG systems have better accuracy in rhythm diagnosis than nonexpert clinicians and (b) both systems provide correct diagnostic suggestions in a large percentage of cases where the diagnosis of nonexpert clinicians is incorrect. Five hundred ECGs were manually analyzed by 2 senior experts, 3 nonexpert clinicians, and automatically by 2 automated systems. The accuracy of the nonexpert rhythm statements was compared with the accuracy of each system statement. The proportion of rhythm statements when the clinician's diagnoses were incorrect and the systems instead provided correct diagnosis was assessed. A total of 420 sinus rhythms and 156 rhythm disturbances were recognized by expert reading. Significance of the difference in accuracy between nonexperts and systems was P = .45 for system A and P = .11 for system B. The percentage of correct automated diagnoses in cases when the clinician was incorrect was 28% ± 10% for system A and 25% ± 11% for system B (P = .09). The rhythm diagnoses of automated systems did not reach better average accuracy than those of nonexpert readings. The computer diagnosis of rhythm can be incorrect in cases where the clinicians fail in reaching the correct ECG diagnosis. Copyright © 2012. Published by Elsevier Inc.
A Deep Learning Approach to Examine Ischemic ST Changes in Ambulatory ECG Recordings.
Xiao, Ran; Xu, Yuan; Pelter, Michele M; Mortara, David W; Hu, Xiao
2018-01-01
Patients with suspected acute coronary syndrome (ACS) are at risk of transient myocardial ischemia (TMI), which could lead to serious morbidity or even mortality. Early detection of myocardial ischemia can reduce damage to heart tissues and improve patient condition. Significant ST change in the electrocardiogram (ECG) is an important marker for detecting myocardial ischemia during the rule-out phase of potential ACS. However, current ECG monitoring software is vastly underused due to excessive false alarms. The present study aims to tackle this problem by combining a novel image-based approach with deep learning techniques to improve the detection accuracy of significant ST depression change. The obtained convolutional neural network (CNN) model yields an average area under the curve (AUC) at 89.6% from an independent testing set. At selected optimal cutoff thresholds, the proposed model yields a mean sensitivity at 84.4% while maintaining specificity at 84.9%.
[Risk management of QT-prolonging drugs by community pharmacists using a mobile electrocardiograph].
Shinozaki, Kohki
2010-11-01
Prolongation of the QT interval is associated with a high risk of serious arrhythmia, i.e., torsades de pointes (TdP). However, in many cases, the QT-prolonging drug(s) is prescribed without performing a thorough check-up of the patient's condition, especially an electrocardiogram. In addition to patient interview, we used an electrocardiogram obtained with a mobile electrocardiograph (RMH-ECG) in a community pharmacy in order to improve the risk management for QT-prolonging drugs. A comparison of the results obtained using RMH-ECG (modified I) and 12-lead ECG (I) revealed that both corrected QT (QTc) values were almost identical, and the correlation coefficient was 0.96. In one month, 5 of 948 patients who visited our pharmacy and continuously took QT-prolonging drugs had additional risk factors for TdP (advanced age, female, and drug-drug interaction). We monitored the QT interval of one of these patients. She had received erythromycin for 19 months along with other drugs metabolized by a P450 (CYP3A4); benidipine and prednisolone (for over 2 years), and tacrolimus (for 13 weeks). Three RMH-ECG tests at every 2 weeks revealed that QTcs were normal (0.43-0.45 s); therefore, we dispensed drugs without any change in the prescription. Approximately 1 in 1200 individuals has a prolonged QT interval without any subjective symptoms, and the time window of drug-induced TdP is considered to be from several hours to months after taking these drugs. Therefore, we think that an ECG test should be performed in community pharmacies before dispensing QT-prolonging drugs and that the QT interval should be monitored.
Sodhro, Ali Hassan; Sodhro, Gul Hassan; Lohano, Sonia; Pirbhulal, Sandeep
2018-01-01
Rapid progress and emerging trends in miniaturized medical devices have enabled the un-obtrusive monitoring of physiological signals and daily activities of everyone’s life in a prominent and pervasive manner. Due to the power-constrained nature of conventional wearable sensor devices during ubiquitous sensing (US), energy-efficiency has become one of the highly demanding and debatable issues in healthcare. This paper develops a single chip-based wearable wireless electrocardiogram (ECG) monitoring system by adopting analog front end (AFE) chip model ADS1292R from Texas Instruments. The developed chip collects real-time ECG data with two adopted channels for continuous monitoring of human heart activity. Then, these two channels and the AFE are built into a right leg drive right leg drive (RLD) driver circuit with lead-off detection and medical graded test signal. Human ECG data was collected at 60 beats per minute (BPM) to 120 BPM with 60 Hz noise and considered throughout the experimental set-up. Moreover, notch filter (cutoff frequency 60 Hz), high-pass filter (cutoff frequency 0.67 Hz), and low-pass filter (cutoff frequency 100 Hz) with cut-off frequencies of 60 Hz, 0.67 Hz, and 100 Hz, respectively, were designed with bilinear transformation for rectifying the power-line noise and artifacts while extracting real-time ECG signals. Finally, a transmission power control-based energy-efficient (ETPC) algorithm is proposed, implemented on the hardware and then compared with the several conventional TPC methods. Experimental results reveal that our developed chip collects real-time ECG data efficiently, and the proposed ETPC algorithm achieves higher energy savings of 35.5% with a slightly larger packet loss ratio (PLR) as compared to conventional TPC (e.g., constant TPC, Gao’s, and Xiao’s methods). PMID:29558433
Cortez, Daniel; Svensson, Anneli; Carlson, Jonas; Graw, Sharon; Sharma, Nandita; Brun, Francesca; Spezzacatene, Anita; Mestroni, Luisa; Platonov, Pyotr G
2017-10-13
Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) carries a risk of sudden death. We aimed to assess whether vectorcardiographic (VCG) parameters directed toward the right heart and a measured angle of the S-wave would help differentiate ARVD/C with otherwise normal electrocardiograms from controls. Task Force 2010 definite ARVD/C criteria were met for all patients. Those who did not fulfill Task Force depolarization or repolarization criteria (-ECG) were compared with age and gender-matched control subjects. Electrocardiogram measures of a 3-dimentional spatial QRS-T angle, a right-precordial-directed orthogonal QRS-T (RPD) angle, a root mean square of the right sided depolarizing forces (RtRMS-QRS), QRS duration (QRSd) and the corrected QT interval (QTc), and a measured angle including the upslope and downslope of the S-wave (S-wave angle) were assessed. Definite ARVD/C was present in 155 patients by 2010 Task Force criteria (41.7 ± 17.6 years, 65.2% male). -ECG ARVD/C patients (66 patients) were compared to 66 control patients (41.7 ± 17.6 years, 65.2% male). All parameters tested except the QRSd and QTc significantly differentiated -ECG ARVD/C from control patients (p < 0.004 to p < 0.001). The RPD angle and RtRMS-QRS best differentiated the groups. Combined, the 2 novel criteria gave 81.8% sensitivity, 90.9% specificity and odds ratio of 45.0 (95% confidence interval 15.8 to 128.2). ARVD/C disease process may lead to development of subtle ECG abnormalities that can be distinguishable using right-sided VCG or measured angle markers better than the spatial QRS-T angle, the QRSd or QTc, in the absence of Taskforce ECG criteria.
Sodhro, Ali Hassan; Sangaiah, Arun Kumar; Sodhro, Gul Hassan; Lohano, Sonia; Pirbhulal, Sandeep
2018-03-20
Rapid progress and emerging trends in miniaturized medical devices have enabled the un-obtrusive monitoring of physiological signals and daily activities of everyone's life in a prominent and pervasive manner. Due to the power-constrained nature of conventional wearable sensor devices during ubiquitous sensing (US), energy-efficiency has become one of the highly demanding and debatable issues in healthcare. This paper develops a single chip-based wearable wireless electrocardiogram (ECG) monitoring system by adopting analog front end (AFE) chip model ADS1292R from Texas Instruments. The developed chip collects real-time ECG data with two adopted channels for continuous monitoring of human heart activity. Then, these two channels and the AFE are built into a right leg drive right leg drive (RLD) driver circuit with lead-off detection and medical graded test signal. Human ECG data was collected at 60 beats per minute (BPM) to 120 BPM with 60 Hz noise and considered throughout the experimental set-up. Moreover, notch filter (cutoff frequency 60 Hz), high-pass filter (cutoff frequency 0.67 Hz), and low-pass filter (cutoff frequency 100 Hz) with cut-off frequencies of 60 Hz, 0.67 Hz, and 100 Hz, respectively, were designed with bilinear transformation for rectifying the power-line noise and artifacts while extracting real-time ECG signals. Finally, a transmission power control-based energy-efficient (ETPC) algorithm is proposed, implemented on the hardware and then compared with the several conventional TPC methods. Experimental results reveal that our developed chip collects real-time ECG data efficiently, and the proposed ETPC algorithm achieves higher energy savings of 35.5% with a slightly larger packet loss ratio (PLR) as compared to conventional TPC (e.g., constant TPC, Gao's, and Xiao's methods).
Ramkumar, Barathram; Sabarimalai Manikandan, M.
2017-01-01
Automatic electrocardiogram (ECG) signal enhancement has become a crucial pre-processing step in most ECG signal analysis applications. In this Letter, the authors propose an automated noise-aware dictionary learning-based generalised ECG signal enhancement framework which can automatically learn the dictionaries based on the ECG noise type for effective representation of ECG signal and noises, and can reduce the computational load of sparse representation-based ECG enhancement system. The proposed framework consists of noise detection and identification, noise-aware dictionary learning, sparse signal decomposition and reconstruction. The noise detection and identification is performed based on the moving average filter, first-order difference, and temporal features such as number of turning points, maximum absolute amplitude, zerocrossings, and autocorrelation features. The representation dictionary is learned based on the type of noise identified in the previous stage. The proposed framework is evaluated using noise-free and noisy ECG signals. Results demonstrate that the proposed method can significantly reduce computational load as compared with conventional dictionary learning-based ECG denoising approaches. Further, comparative results show that the method outperforms existing methods in automatically removing noises such as baseline wanders, power-line interference, muscle artefacts and their combinations without distorting the morphological content of local waves of ECG signal. PMID:28529758
Satija, Udit; Ramkumar, Barathram; Sabarimalai Manikandan, M
2017-02-01
Automatic electrocardiogram (ECG) signal enhancement has become a crucial pre-processing step in most ECG signal analysis applications. In this Letter, the authors propose an automated noise-aware dictionary learning-based generalised ECG signal enhancement framework which can automatically learn the dictionaries based on the ECG noise type for effective representation of ECG signal and noises, and can reduce the computational load of sparse representation-based ECG enhancement system. The proposed framework consists of noise detection and identification, noise-aware dictionary learning, sparse signal decomposition and reconstruction. The noise detection and identification is performed based on the moving average filter, first-order difference, and temporal features such as number of turning points, maximum absolute amplitude, zerocrossings, and autocorrelation features. The representation dictionary is learned based on the type of noise identified in the previous stage. The proposed framework is evaluated using noise-free and noisy ECG signals. Results demonstrate that the proposed method can significantly reduce computational load as compared with conventional dictionary learning-based ECG denoising approaches. Further, comparative results show that the method outperforms existing methods in automatically removing noises such as baseline wanders, power-line interference, muscle artefacts and their combinations without distorting the morphological content of local waves of ECG signal.
A new technique for simultaneous monitoring of electrocardiogram and walking cadence
NASA Technical Reports Server (NTRS)
Hausdorff, J. M.; Forman, D. E.; Pilgrim, D. M.; Rigney, D. R.; Wei, J. Y.; Goldberger, A. L. (Principal Investigator)
1992-01-01
A new technique for simultaneously recording continuous electrocardiographic (ECG) data and walking step rate (cadence) is described. The ECG and gait signals are recorded on 2 channels of an ambulatory Holter monitor. Footfall is detected using ultrathin, force-sensitive foot switches and is frequency modulated. The footfall signal provides an indication of the subject's activity (walking or standing), as well as the instantaneous walking rate. Twenty-three young and elderly subjects were studied to demonstrate the use of this ECG and gait recorder. High-quality gait signals were obtained in all subjects, and the effects of walking on the electrocardiogram were assessed. Initial investigation revealed the following findings: (1) Although walking rates were similar in young and elderly subjects, the elderly had both decreased heart rate (HR) variability (p < 0.005) and increased cadence variability (p < 0.0001). (2) Overall, there was an inverse relation between HR and cadence variability (r = -0.73). Three elderly subjects with no known cardiac disease had HR and cadence variability similar to those of the young, whereas elderly subjects with history of congestive heart failure were among those with the lowest HR variability and the highest cadence variability. (3) Low-frequency (approximately equal to 0.1 Hz) HR oscillations (frequently observed during standing) persisted during walking in all young subjects. (4) In some subjects, both step rate and HR oscillated at the same low frequency (approximately equal to 0.1 Hz) previously identified with autonomic control of the baroreflex.(ABSTRACT TRUNCATED AT 250 WORDS).
Ogo, Takeshi; Fukuda, Tetsuya; Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin; Sanda, Yoshihiro; Morita, Yoshiaki; Asano, Ryotaro; Konagai, Nao; Yasuda, Satoshi
2017-04-01
Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1year after BPA. Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Electrocardiographic features of patients with earthquake related posttraumatic stress disorder
İlhan, Erkan; Kaplan, Abdullah; Güvenç, Tolga Sinan; Biteker, Murat; Karabulut, Evindar; Işıklı, Serhan
2013-01-01
AIM: To analyze electrocardiographic features of patients diagnosed with posttraumatic stress disorder (PTSD) after the Van-Erciş earthquake, with a shock measuring 7.2 on the Richter scale that took place in Turkey in October 2011. METHODS: Surface electrocardiograms of 12 patients with PTSD admitted to Van Erciş State Hospital (Van, Turkey) from February 2012 to May 2012 were examined. Psychiatric interviews of the sex and age matched control subjects, who had experienced the earthquake, confirmed the absence of any known diagnosable psychiatric conditions in the control group. RESULTS: A wide range of electrocardiogram (ECG) parameters, such as P-wave dispersion, QT dispersion, QT interval, Tpeak to Tend interval, intrinsicoid deflection durations and other traditional parameters were similar in both groups. There was no one with an abnormal P wave axis, short or long PR interval, long or short QT interval, negative T wave in lateral leads, abnormal T wave axis, abnormal left or right intrinsicoid deflection duration, low voltage, left bundle branch block, right bundle branch block, left posterior hemiblock, left or right axis deviation, left ventricular hypertrophy, right or left atrial enlargement and pathological q(Q) wave in either group. CONCLUSION: The study showed no direct effect of earthquake related PTSD on surface ECG in young patients. So, we propose that PTSD has no direct effect on surface ECG but may cause electrocardiographic changes indirectly by triggering atherosclerosis and/or contributing to the ongoing atherosclerotic process. PMID:23538549
Advanced ECG in 2016: is there more than just a tracing?
Reichlin, Tobias; Abächerli, Roger; Twerenbold, Raphael; Kühne, Michael; Schaer, Beat; Müller, Christian; Sticherling, Christian; Osswald, Stefan
2016-01-01
The 12-lead electrocardiogram (ECG) is the most frequently used technology in clinical cardiology. It is critical for evidence-based management of patients with most cardiovascular conditions, including patients with acute myocardial infarction, suspected chronic cardiac ischaemia, cardiac arrhythmias, heart failure and implantable cardiac devices. In contrast to many other techniques in cardiology, the ECG is simple, small, mobile, universally available and cheap, and therefore particularly attractive. Standard ECG interpretation mainly relies on direct visual assessment. The progress in biomedical computing and signal processing, and the available computational power offer fascinating new options for ECG analysis relevant to all fields of cardiology. Several digital ECG markers and advanced ECG technologies have shown promise in preliminary studies. This article reviews promising novel surface ECG technologies in three different fields. (1) For the detection of myocardial ischaemia and infarction, QRS morphology feature analysis, the analysis of high frequency QRS components (HF-QRS) and methods using vectorcardiography as well as ECG imaging are discussed. (2) For the identification and management of patients with cardiac arrhythmias, methods of advanced P-wave analysis are discussed and the concept of ECG imaging for noninvasive localisation of cardiac arrhythmias is presented. (3) For risk stratification of sudden cardiac death and the selection of patients for medical device therapy, several novel markers including an automated QRS-score for scar quantification, the QRS-T angle or the T-wave peak-to-end-interval are discussed. Despite the existing preliminary data, none of the advanced ECG markers and technologies has yet accomplished the transition into clinical practice. Further refinement of these technologies and broader validation in large unselected patient cohorts are the critical next step needed to facilitate translation of advanced ECG technologies into clinical cardiology.
Ma, JiaLi; Zhang, TanTan; Dong, MingChui
2015-05-01
This paper presents a novel electrocardiogram (ECG) compression method for e-health applications by adapting an adaptive Fourier decomposition (AFD) algorithm hybridized with a symbol substitution (SS) technique. The compression consists of two stages: first stage AFD executes efficient lossy compression with high fidelity; second stage SS performs lossless compression enhancement and built-in data encryption, which is pivotal for e-health. Validated with 48 ECG records from MIT-BIH arrhythmia benchmark database, the proposed method achieves averaged compression ratio (CR) of 17.6-44.5 and percentage root mean square difference (PRD) of 0.8-2.0% with a highly linear and robust PRD-CR relationship, pushing forward the compression performance to an unexploited region. As such, this paper provides an attractive candidate of ECG compression method for pervasive e-health applications.
Regulatory issues for computerized electrocardiographic devices.
Muni, Neal I; Ho, Charles; Mallis, Elias
2004-01-01
Computerized electrocardiogram (ECG) devices are regulated in the U.S. by the FDA Center for Devices and Radiological Health (CDRH). This article aims to highlight the salient points of the FDA regulatory review process, including the important distinction between a "tool" claim and a "clinical" claim in the intended use of a computerized ECG device. Specifically, a tool claim relates to the ability of the device to accurately measure a certain ECG parameter, such as T-wave alternans (TWA), while a clinical claim imputes a particular health hazard associated with the identified parameter, such as increased risk of ventricular tachyarrhythmia or sudden death. Given that both types of claims are equally important and receive the same regulatory scrutiny, the manufacturer of a new ECG diagnostic device should consider the distinction and regulatory pathways for approval between the two types of claims discussed in this paper.
Sufi, Fahim; Khalil, Ibrahim
2009-04-01
With cardiovascular disease as the number one killer of modern era, Electrocardiogram (ECG) is collected, stored and transmitted in greater frequency than ever before. However, in reality, ECG is rarely transmitted and stored in a secured manner. Recent research shows that eavesdropper can reveal the identity and cardiovascular condition from an intercepted ECG. Therefore, ECG data must be anonymized before transmission over the network and also stored as such in medical repositories. To achieve this, first of all, this paper presents a new ECG feature detection mechanism, which was compared against existing cross correlation (CC) based template matching algorithms. Two types of CC methods were used for comparison. Compared to the CC based approaches, which had 40% and 53% misclassification rates, the proposed detection algorithm did not perform any single misclassification. Secondly, a new ECG obfuscation method was designed and implemented on 15 subjects using added noises corresponding to each of the ECG features. This obfuscated ECG can be freely distributed over the internet without the necessity of encryption, since the original features needed to identify personal information of the patient remain concealed. Only authorized personnel possessing a secret key will be able to reconstruct the original ECG from the obfuscated ECG. Distribution of the would appear as regular ECG without encryption. Therefore, traditional decryption techniques including powerful brute force attack are useless against this obfuscation.
Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle
NASA Technical Reports Server (NTRS)
Moore, A. D. Jr; Lee, S. M.; Greenisen, M. C.; Bishop, P.
1997-01-01
Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.
El B'charri, Oussama; Latif, Rachid; Elmansouri, Khalifa; Abenaou, Abdenbi; Jenkal, Wissam
2017-02-07
Since the electrocardiogram (ECG) signal has a low frequency and a weak amplitude, it is sensitive to miscellaneous mixed noises, which may reduce the diagnostic accuracy and hinder the physician's correct decision on patients. The dual tree wavelet transform (DT-WT) is one of the most recent enhanced versions of discrete wavelet transform. However, threshold tuning on this method for noise removal from ECG signal has not been investigated yet. In this work, we shall provide a comprehensive study on the impact of the choice of threshold algorithm, threshold value, and the appropriate wavelet decomposition level to evaluate the ECG signal de-noising performance. A set of simulations is performed on both synthetic and real ECG signals to achieve the promised results. First, the synthetic ECG signal is used to observe the algorithm response. The evaluation results of synthetic ECG signal corrupted by various types of noise has showed that the modified unified threshold and wavelet hyperbolic threshold de-noising method is better in realistic and colored noises. The tuned threshold is then used on real ECG signals from the MIT-BIH database. The results has shown that the proposed method achieves higher performance than the ordinary dual tree wavelet transform into all kinds of noise removal from ECG signal. The simulation results indicate that the algorithm is robust for all kinds of noises with varying degrees of input noise, providing a high quality clean signal. Moreover, the algorithm is quite simple and can be used in real time ECG monitoring.
Novel technical solutions for wireless ECG transmission & analysis in the age of the internet cloud.
Al-Zaiti, Salah S; Shusterman, Vladimir; Carey, Mary G
2013-01-01
Current guidelines recommend early reperfusion therapy for ST-elevation myocardial infarction (STEMI) within 90 min of first medical encounter. Telecardiology entails the use of advanced communication technologies to transmit the prehospital 12-lead electrocardiogram (ECG) to offsite cardiologists for early triage to the cath lab; which has been shown to dramatically reduce door-to-balloon time and total mortality. However, hospitals often find adopting ECG transmission technologies very challenging. The current review identifies seven major technical challenges of prehospital ECG transmission, including: paramedics inconvenience and transport delay; signal noise and interpretation errors; equipment malfunction and transmission failure; reliability of mobile phone networks; lack of compliance with the standards of digital ECG formats; poor integration with electronic medical records; and costly hardware and software pre-requisite installation. Current and potential solutions to address each of these technical challenges are discussed in details and include: automated ECG transmission protocols; annotatable waveform-based ECGs; optimal routing solutions; and the use of cloud computing systems rather than vendor-specific processing stations. Nevertheless, strategies to monitor transmission effectiveness and patient outcomes are essential to sustain initial gains of implementing ECG transmission technologies. © 2013.
History of research in Japan on electrocardiography in the racehorse
HIRAGA, Atsushi; SUGANO, Shigeru
2015-01-01
ABSTRACT Since the first recording of electrocardiograms (ECGs) of a horse in Japan was carried out in 1944, studies on ECGs have been performed intensively. During the early stages of research from the 1950s to 1960s, leads to use for ECG recording were evaluated using several different approaches including unipolar leads, bipolar limb leads, and bipolar chest leads. Based on these studies, the AB lead, which is oriented along the long axis of the heart, became the standard reference method in Japan. Electrodes of the AB lead are placed on the upper 1/4th point along a straight line between the withers and the left shoulder blade (base: B), and 10 cm posterior to the left olecranon (apex: A). The incidence of equine arrhythmias among racehorses has been surveyed, and details of the electrocardiographic characteristics of several arrhythmias have been investigated. In particular, atrial fibrillation (AF) has been extensively studied, and papers have reported findings such as that paroxysmal AF occurs during racing and described electrocardiographic changes that occur at the onset of AF during exercise. Development of a radiotelemetry system for ECG recording enabled the first recording of equine ECGs during galloping in 1964, the detection of arrhythmias, and calculation of heart rate during exercise. Studies on comparative and developmental changes of ECGs have described characteristics of the equine ECGs. Future research on changes in cardiac function, including autonomic function, that occur with aging may lead to new developments in equine electrocardiography and contribute to improving the health and welfare of the horse. PMID:25829865
Yamamoto, Yuki; Yamamoto, Daisuke; Takada, Makoto; Naito, Hiroyoshi; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu
2017-09-01
Wearable, flexible healthcare devices, which can monitor health data to predict and diagnose disease in advance, benefit society. Toward this future, various flexible and stretchable sensors as well as other components are demonstrated by arranging materials, structures, and processes. Although there are many sensor demonstrations, the fundamental characteristics such as the dependence of a temperature sensor on film thickness and the impact of adhesive for an electrocardiogram (ECG) sensor are yet to be explored in detail. In this study, the effect of film thickness for skin temperature measurements, adhesive force, and reliability of gel-less ECG sensors as well as an integrated real-time demonstration is reported. Depending on the ambient conditions, film thickness strongly affects the precision of skin temperature measurements, resulting in a thin flexible film suitable for a temperature sensor in wearable device applications. Furthermore, by arranging the material composition, stable gel-less sticky ECG electrodes are realized. Finally, real-time simultaneous skin temperature and ECG signal recordings are demonstrated by attaching an optimized device onto a volunteer's chest. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Remote health monitoring system for detecting cardiac disorders.
Bansal, Ayush; Kumar, Sunil; Bajpai, Anurag; Tiwari, Vijay N; Nayak, Mithun; Venkatesan, Shankar; Narayanan, Rangavittal
2015-12-01
Remote health monitoring system with clinical decision support system as a key component could potentially quicken the response of medical specialists to critical health emergencies experienced by their patients. A monitoring system, specifically designed for cardiac care with electrocardiogram (ECG) signal analysis as the core diagnostic technique, could play a vital role in early detection of a wide range of cardiac ailments, from a simple arrhythmia to life threatening conditions such as myocardial infarction. The system that the authors have developed consists of three major components, namely, (a) mobile gateway, deployed on patient's mobile device, that receives 12-lead ECG signals from any ECG sensor, (b) remote server component that hosts algorithms for accurate annotation and analysis of the ECG signal and (c) point of care device of the doctor to receive a diagnostic report from the server based on the analysis of ECG signals. In the present study, their focus has been toward developing a system capable of detecting critical cardiac events well in advance using an advanced remote monitoring system. A system of this kind is expected to have applications ranging from tracking wellness/fitness to detection of symptoms leading to fatal cardiac events.
Evaluation of heart rate variability indices using a real-time handheld remote ECG monitor.
Singh, Swaroop S; Carlson, Barbara W; Hsiao, Henry S
2007-12-01
Studies on retrospective electrocardiogram (ECG) recordings of patients during cardiac arrest have shown significant changes in heart rate variability (HRV) indices prior to the onset of cardiac arrhythmia. The early detection of these changes in HRV indices increases the chances for a successful medical intervention by increasing the response time window. A portable, handheld remote ECG monitor designed in this research detects the QRS complex and calculates short-term HRV indices in real-time. The QRS detection of the ECG recordings of subjects from the MIT-Arrhythmia database yielded a mean sensitivity of 99.34% and a specificity of 99.31%. ECG recordings from normal subjects and subjects with congestive heart failure were used to identify the differences in HRV indices. An increase in heart rate, high-frequency spectral power (HFP), total spectral power, the ratio of HFP to low-frequency spectral power (LFP), and a decrease in root mean square sum of RR differences were observed. No difference was found on comparison of the standard deviation of normal to normal interval between adjacent R-waves, LFP, and very-low-frequency spectral power. Based on these, additional analytical calculations could be made to provide early warnings of impending cardiac conditions.
Jekova, Irena; Krasteva, Vessela; Leber, Remo; Schmid, Ramun; Twerenbold, Raphael; Müller, Christian; Reichlin, Tobias; Abächerli, Roger
Electrocardiogram (ECG) biometrics is an advanced technology, not yet covered by guidelines on criteria, features and leads for maximal authentication accuracy. This study aims to define the minimal set of morphological metrics in 12-lead ECG by optimization towards high reliability and security, and validation in a person verification model across a large population. A standard 12-lead resting ECG database from 574 non-cardiac patients with two remote recordings (>1year apart) was used. A commercial ECG analysis module (Schiller AG) measured 202 morphological features, including lead-specific amplitudes, durations, ST-metrics, and axes. Coefficient of variation (CV, intersubject variability) and percent-mean-absolute-difference (PMAD, intrasubject reproducibility) defined the optimization (PMAD/CV→min) and restriction (CV<30%) criteria for selection of the most stable and distinctive features. Linear discriminant analysis (LDA) validated the non-redundant feature set for person verification. Maximal LDA verification sensitivity (85.3%) and specificity (86.4%) were validated for 11 optimal features: R-amplitude (I,II,V1,V2,V3,V5), S-amplitude (V1,V2), Tnegative-amplitude (aVR), and R-duration (aVF,V1). Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Schlegel, Todd T.; Kulecz, Walter B.; DePalma, Jude L.; Feiveson, Alan H.; Wilson, John S.; Rahman, M. Atiar; Bungo, Michael W.
2004-01-01
Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.
Fusion of ECG and ABP signals based on wavelet transform for cardiac arrhythmias classification.
Arvanaghi, Roghayyeh; Daneshvar, Sabalan; Seyedarabi, Hadi; Goshvarpour, Atefeh
2017-11-01
Each of Electrocardiogram (ECG) and Atrial Blood Pressure (ABP) signals contain information of cardiac status. This information can be used for diagnosis and monitoring of diseases. The majority of previously proposed methods rely only on ECG signal to classify heart rhythms. In this paper, ECG and ABP were used to classify five different types of heart rhythms. To this end, two mentioned signals (ECG and ABP) have been fused. These physiological signals have been used from MINIC physioNet database. ECG and ABP signals have been fused together on the basis of the proposed Discrete Wavelet Transformation fusion technique. Then, some frequency features were extracted from the fused signal. To classify the different types of cardiac arrhythmias, these features were given to a multi-layer perceptron neural network. In this study, the best results for the proposed fusion algorithm were obtained. In this case, the accuracy rates of 96.6%, 96.9%, 95.6% and 93.9% were achieved for two, three, four and five classes, respectively. However, the maximum classification rate of 89% was obtained for two classes on the basis of ECG features. It has been found that the higher accuracy rates were acquired by using the proposed fusion technique. The results confirmed the importance of fusing features from different physiological signals to gain more accurate assessments. Copyright © 2017 Elsevier B.V. All rights reserved.
SPEAR Trial: Smartphone Pediatric ElectrocARdiogram Trial
Nguyen, Hoang H.; Van Hare, George F.; Rudokas, Michael; Bowman, Tammy; Silva, Jennifer N. A.
2015-01-01
Objectives Smartphone-enabled ECG devices have the potential to improve patient care by enabling remote ECG assessment of patients with potential and diagnosed arrhythmias. This prospective study aimed to assess the usefulness of pediatric ECG tracings generated by the AliveCor device (Oklahoma City, OK) and to assess user satisfaction. Study Design Enrolled pediatric patients with documented paroxysmal arrhythmia used the AliveCor device over a yearlong study period. Pediatric electrophysiologists reviewed all transmitted ECG tracings. Patient completed surveys were analyzed to assess user satisfaction. Results 35 patients were enrolled with the following diagnoses: supraventricular tachycardia (SVT, 57%), atrial fibrillation (AF, 11%), ectopic atrial tachycardia (EAT, 6%), atrial tachycardia (AT, 3%), and ventricular tachycardia (VT, 23%). A total of 238 tracings were received from 20 patients, 96% of which were of diagnostic quality for sinus rhythm, sinus tachycardia, SVT, and AF. 126 patient satisfaction surveys (64% from parents) were completed. 98% of the survey responses indicated that it was easy to obtain tracings, 93% found it easy to transmit the tracings, 98% showed added comfort in managing arrhythmia by having the device, and 93% showed interest in continued use of the device after the study period ended. Conclusions Smartphone-enabled ECG devices can generate tracings of diagnostic quality in children. User satisfaction was extremely positive. Use of the device to manage certain patients with AF and SVT showcases the future role of remote ECGs in the successful outpatient management of arrhythmias in children by potentially reducing Emergency Department visits and healthcare costs. PMID:26295569
Improving ECG Competence in Medical Trainees in a UK District General Hospital
McAloon, Christopher; Leach, Helen; Gill, Simrat; Aluwalia, Arun; Trevelyan, Jasper
2014-01-01
Background Competency in electrocardiogram (ECG) interpretation is central to undergraduate and postgraduate clinical training. Studies have demonstrated ECGs are interpreted sub-optimally. Our study compares the effectiveness of two learning strategies to improve competence and confidence. Method A 1-month prospective randomized study compared the strategies in two cohorts: undergraduate third year medical students and postgraduate foundation year one (FY1) doctors. Both had blinded randomization to one of these learning strategies: focused teaching program (FTP) and self-directed learning (SDL). All volunteers completed a confidence questionnaire before and after allocation learning strategy and an ECG recognition multiple choice question (MCQ) paper at the end of the learning period. Results The FTP group of undergraduates demonstrated a significant difference in successfully interpreting “ventricular tachycardia” (P = 0.046) and “narrow complex tachycardia” (P = 0.009) than the SDL group. Participant confidence increased in both learning strategies. FTP confidence demonstrated a greater improvement than SDL for both cohorts. Conclusion A dedicated teaching program can improve trainee confidence and competence in ECG interpretation. A larger benefit is observed in undergraduates and those undertaking a FTP. PMID:28392875
Bond, R R; Zhu, T; Finlay, D D; Drew, B; Kligfield, P D; Guldenring, D; Breen, C; Gallagher, A G; Daly, M J; Clifford, G D
2014-01-01
It is well known that accurate interpretation of the 12-lead electrocardiogram (ECG) requires a high degree of skill. There is also a moderate degree of variability among those who interpret the ECG. While this is the case, there are no best practice guidelines for the actual ECG interpretation process. Hence, this study adopts computerized eye tracking technology to investigate whether eye-gaze can be used to gain a deeper insight into how expert annotators interpret the ECG. Annotators were recruited in San Jose, California at the 2013 International Society of Computerised Electrocardiology (ISCE). Each annotator was recruited to interpret a number of 12-lead ECGs (N=12) while their eye gaze was recorded using a Tobii X60 eye tracker. The device is based on corneal reflection and is non-intrusive. With a sampling rate of 60Hz, eye gaze coordinates were acquired every 16.7ms. Fixations were determined using a predefined computerized classification algorithm, which was then used to generate heat maps of where the annotators looked. The ECGs used in this study form four groups (3=ST elevation myocardial infarction [STEMI], 3=hypertrophy, 3=arrhythmias and 3=exhibiting unique artefacts). There was also an equal distribution of difficulty levels (3=easy to interpret, 3=average and 3=difficult). ECGs were displayed using the 4x3+1 display format and computerized annotations were concealed. Precisely 252 expert ECG interpretations (21 annotators×12 ECGs) were recorded. Average duration for ECG interpretation was 58s (SD=23). Fleiss' generalized kappa coefficient (Pa=0.56) indicated a moderate inter-rater reliability among the annotators. There was a 79% inter-rater agreement for STEMI cases, 71% agreement for arrhythmia cases, 65% for the lead misplacement and dextrocardia cases and only 37% agreement for the hypertrophy cases. In analyzing the total fixation duration, it was found that on average annotators study lead V1 the most (4.29s), followed by leads V2 (3.83s), the rhythm strip (3.47s), II (2.74s), V3 (2.63s), I (2.53s), aVL (2.45s), V5 (2.27s), aVF (1.74s), aVR (1.63s), V6 (1.39s), III (1.32s) and V4 (1.19s). It was also found that on average the annotator spends an equal amount of time studying leads in the frontal plane (15.89s) when compared to leads in the transverse plane (15.70s). It was found that on average the annotators fixated on lead I first followed by leads V2, aVL, V1, II, aVR, V3, rhythm strip, III, aVF, V5, V4 and V6. We found a strong correlation (r=0.67) between time to first fixation on a lead and the total fixation duration on each lead. This indicates that leads studied first are studied the longest. There was a weak negative correlation between duration and accuracy (r=-0.2) and a strong correlation between age and accuracy (r=0.67). Eye tracking facilitated a deeper insight into how expert annotators interpret the 12-lead ECG. As a result, the authors recommend ECG annotators to adopt an initial first impression/pattern recognition approach followed by a conventional systematic protocol to ECG interpretation. This recommendation is based on observing misdiagnoses given due to first impression only. In summary, this research presents eye gaze results from expert ECG annotators and provides scope for future work that involves exploiting computerized eye tracking technology to further the science of ECG interpretation. Copyright © 2014 Elsevier Inc. All rights reserved.
Bhaumik, Basabi
2016-01-01
A novel algorithm based on forward search is developed for real-time electrocardiogram (ECG) signal processing and implemented in application specific integrated circuit (ASIC) for QRS complex related cardiovascular disease diagnosis. The authors have evaluated their algorithm using MIT-BIH database and achieve sensitivity of 99.86% and specificity of 99.93% for QRS complex peak detection. In this Letter, Physionet PTB diagnostic ECG database is used for QRS complex related disease detection. An ASIC for cardiovascular disease detection is fabricated using 130-nm CMOS high-speed process technology. The area of the ASIC is 0.5 mm2. The power dissipation is 1.73 μW at the operating frequency of 1 kHz with a supply voltage of 0.6 V. The output from the ASIC is fed to their Android application that generates diagnostic report and can be sent to a cardiologist through email. Their ASIC result shows average failed detection rate of 0.16% for six leads data of 290 patients in PTB diagnostic ECG database. They also have implemented a low-leakage version of their ASIC. The ASIC dissipates only 45 pJ with a supply voltage of 0.9 V. Their proposed ASIC is most suitable for energy efficient telemetry cardiovascular disease detection system. PMID:27284458
Jain, Sanjeev Kumar; Bhaumik, Basabi
2016-03-01
A novel algorithm based on forward search is developed for real-time electrocardiogram (ECG) signal processing and implemented in application specific integrated circuit (ASIC) for QRS complex related cardiovascular disease diagnosis. The authors have evaluated their algorithm using MIT-BIH database and achieve sensitivity of 99.86% and specificity of 99.93% for QRS complex peak detection. In this Letter, Physionet PTB diagnostic ECG database is used for QRS complex related disease detection. An ASIC for cardiovascular disease detection is fabricated using 130-nm CMOS high-speed process technology. The area of the ASIC is 0.5 mm(2). The power dissipation is 1.73 μW at the operating frequency of 1 kHz with a supply voltage of 0.6 V. The output from the ASIC is fed to their Android application that generates diagnostic report and can be sent to a cardiologist through email. Their ASIC result shows average failed detection rate of 0.16% for six leads data of 290 patients in PTB diagnostic ECG database. They also have implemented a low-leakage version of their ASIC. The ASIC dissipates only 45 pJ with a supply voltage of 0.9 V. Their proposed ASIC is most suitable for energy efficient telemetry cardiovascular disease detection system.
Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Çiçek, Yüksel; Çetin, Mustafa; Duman, Hakan; Şatiroğlu, Ömer; Çelik, Şükrü
2017-03-01
Prolonged QRS duration is associated with decreased left ventricular (LV) systolic function. However, the relation between LV restrictive filling pattern (RFP) and QRS duration has not been investigated yet. The purpose of our study was to assess this relationship. We analyzed standard 12-lead surface electrocardiogram (ECG) of 155 consecutive patients. Mitral inflow and septal tissue velocities were obtained using the apical 4-chamber view with pulsed Doppler echocardiography. Patients were divided into 2 groups according to measured deceleration time (DT): restrictive (with DT ≤130 ms) or non-restrictive (with DT >130 ms). QRS duration was significantly longer in the restrictive group than in the non-restrictive group (0.101 vs. 0.090 s, p < 0.0001). QRS duration of >0.10 s was highly specific (82.6%), but modestly sensitive (64.7%), for the prediction of LV RFP. Multivariate analyses demonstrated that E/A ratio, peak E, peak A, septal e', and a' velocities were significantly associated with RFP. Prolonged QRS duration (>0.10 s) obtained from a standard resting 12-lead ECG is associated with LV RFP. However, the relationship of QRS duration with RFP was not independent of echocardiographic parameters.
Urtnasan, Erdenebayar; Park, Jong-Uk; Lee, Kyoung-Joung
2018-05-24
In this paper, we propose a convolutional neural network (CNN)-based deep learning architecture for multiclass classification of obstructive sleep apnea and hypopnea (OSAH) using single-lead electrocardiogram (ECG) recordings. OSAH is the most common sleep-related breathing disorder. Many subjects who suffer from OSAH remain undiagnosed; thus, early detection of OSAH is important. In this study, automatic classification of three classes-normal, hypopnea, and apnea-based on a CNN is performed. An optimal six-layer CNN model is trained on a training dataset (45,096 events) and evaluated on a test dataset (11,274 events). The training set (69 subjects) and test set (17 subjects) were collected from 86 subjects with length of approximately 6 h and segmented into 10 s durations. The proposed CNN model reaches a mean -score of 93.0 for the training dataset and 87.0 for the test dataset. Thus, proposed deep learning architecture achieved a high performance for multiclass classification of OSAH using single-lead ECG recordings. The proposed method can be employed in screening of patients suspected of having OSAH. © 2018 Institute of Physics and Engineering in Medicine.
Suitable Adaptation Mechanisms for Intelligent Tutoring Technologies
2010-12-01
the Acoustic Society of America, 93(2), pp. 1097-1108. Neurofeedback equipment - Wireless Brainquiry PET EEG and ActivEEG. (n.d.). Retrieved from...27 5.2 Electroencephalogram ( EEG ...electroencephalogram ( EEG ), heart rate variability (HRV- a measure involving the electrocardiogram [ECG]), and galvanic skin response (GSR) either
Takakuwa, Kevin M; Burek, Gregory A; Estepa, Adrian T; Shofer, Frances S
2009-10-01
The objectives were to determine if an emergency department (ED) could improve the adherence to a door-to-electrocardiogram (ECG) time goal of 10 minutes or less for patients who presented to an ED with chest pain and the effect of this adherence on door-to-balloon (DTB) time for ST-segment elevation myocardial infarction (STEMI) cardiac catheterization (cath) alert patients. This was a planned 1-month before-and-after interventional study design for implementing a new process for obtaining ECGs in patients presenting to the study ED with chest pain. Prior to the change, patients were registered and triaged before an ECG was obtained. The new procedure required registration clerks to identify those with chest pain and directly overhead page or call a designated ECG technician. This technician had other ED duties, but prioritized performing ECGs and delivering them to attending physicians. A full registration process occurred after the clinical staff performed their initial assessment. The primary outcome was the total percentage of patients with chest pain who received an ECG within 10 minutes of ED arrival. The secondary outcome was DTB time for patients with STEMI who were emergently cath alerted. Data were analyzed using mean differences, 95% confidence intervals (CIs), and relative risk (RR) regression to adjust for possible confounders. A total of 719 patients were studied: 313 before and 405 after the intervention. The mean (+/-standard deviation [SD]) age was 50 (+/-16) years, 54% were women, 57% were African American, and 36% were white. Patients walked in 89% of the time; 11% arrived by ambulance. Thirty-nine percent were triaged as emergent and 61% as nonemergent. Patients presented during daytime 68% of the time, and 32% presented during the night. Before the intervention, 16% received an ECG at 10 minutes or less. After the intervention, 64% met the time requirement, for a mean difference of 47.3% (95% CI = 40.8% to 53.3%, p < 0.0001). Results were not affected by age, sex, race, mode of arrival, triage classification, or time of arrival. For patients with STEMI cath alerts, four were seen before and seven after the intervention. No patients before the intervention had ECG time within 10 minutes, and one of four had DTB time of <90 minutes. After the intervention, all seven patients had ECG time within 10 minutes; the three arriving during weekday hours when the cath team was on site had DTB times of <90 minutes, but the four arriving at night and on weekends when the cath team was off site had DTB times of >90 minutes. The overall percentage of patients with a door-to-ECG time within 10 minutes improved without increasing staffing. An ECG was performed within 10 minutes of arrival for all patients who were STEMI cath alerted, but DTB time under 90 minutes was achieved only when the cath team was on site.
Nabeshima, Yuji; Kimura, Yoshitaka; Ito, Takuro; Ohwada, Kazunari; Karashima, Akihiro; Katayama, Norihiro; Nakao, Mitsuyuki
2013-01-01
Fetal electrocardiogram (fECG) and its vector form (fVECG) could provide significant clinical information concerning physiological conditions of a fetus. So far various independent component analysis (ICA)-based methods for extracting fECG from maternal abdominal signals have been proposed. Because full extraction of component waves such as P, Q, R, S, and T, is difficult to be realized under noisy and nonstationary situations, the fVECG is further hard to be reconstructed, where different projections of the fetal heart vector are required. In order to reconstruct fVECG, we proposed a novel method for synthesizing different projections of the heart vector, making good use of the fetus movement. This method consists of ICA, estimation of rotation angles of fetus, and synthesis of projections of the heart vector. Through applications to the synthetic and actual data, our method is shown to precisely estimate rotation angle of the fetus and to successfully reconstruct the fVECG.
Electrocardiographical case. A tale of tall T's. Hyperkalaemia.
Chew, H C; Lim, S H
2005-08-01
A 63-year-old woman presented at the emergency department (ED) with a history of increasing lethargy and drowsiness. The electrocardiogram (ECG) showed tall peaked T waves with broadening of the QRS interval, suggestive of hyperkalaemia. This patient had an elevated serum potassium level due to diabetic ketoacidosis. She was treated with intravenous calcium chloride and insulin with 50% dextrose. The ECG changes associated with hyperkalaemia are discussed, with illustrations from a second 48-year-old male patient with renal failure who presented with malaise, lethargy and generalised weakness.
Cardiac conductive disturbance in patients with polycystic ovary syndrome.
Huang, Jen-Hung; Tsai, Jen-Chen; Hsu, Ming-I; Chen, Yi-Jen
2010-12-01
Polycystic ovary syndrome (PCOS) is the most common endocrine abnormality of reproductive-aged women and increases the risk of cardiovascular disease. However, the effects of PCOS on electrocardiograms (ECGs) are not fully elucidated. The aim of this study was to evaluate the characteristics of ECGs in patients with PCOS. This study included 24 patients with PCOS and 12 patients without PCOS. The heart rate, PR interval, QRS duration, Sokolow-Lyon voltage (SV1 + RV5/6), Cornell voltage (RaVL + SV3), QT interval and QTc interval were measured in 12-lead ECGs. The QRS duration was wider in patients with PCOS than those without PCOS (91 ± 8 vs. 81 ± 10 ms, p < 0.05). The heart rate, PR interval, Sokolow-Lyon voltage, product of the QRS duration times Cornell voltage combination, QT interval, QTc interval, QT dispersion and QTc dispersion were similar between the two groups. PCOS is associated with a widening QRS duration, which may contribute to its increased cardiovascular risks.
Occhetta, Eraldo; Dell'Era, Gabriele; Giubertoni, Ailia; Magnani, Andrea; Rametta, Francesco; Blandino, Alessandro; Magnano, Vincenzo; Malacrida, Maurizio; Marino, Paolo
2017-04-01
The occurrence of left ventricular (LV) anodal activation during pacing with modern multipolar cardiac resynchronization therapy (CRT) systems has never been reported. The aim of our study was to demonstrate, by means of electrocardiogram (ECG) analysis, the occurrence of simultaneous cathodal-anodal LV capture with quadripolar LV leads. We studied 10 first-time recipients of a CRT device equipped with a quadripolar LV lead. During follow-up, standard supine 12-lead ECGs were obtained in available cathode-to-anode LV pacing configurations with a pulse amplitude equal to twice the pacing threshold. The occurrence of simultaneous cathodal-anodal LV capture was defined as the presence of variations in electrocardiographic ventricular activation (EVA) when the distal tip (cathode)-to-device can (anode) pacing configuration was compared with the distal tip (cathode)-to-proximal ring (anode) configuration. In eight patients, we found differences in EVA when different LV sites were paced through the unipolar LV tip and unipolar LV ring configurations. In these patients, a difference in EVA was detected in 61.5% (59 of 96) of the ECG leads (marked difference in 31.3%, slight difference in 30.2%). Changes in EVA between unipolar tip-to-can and bipolar tip-to-ring pacing that were suggestive of cathodal-anodal LV capture were found in six patients. In these patients, a total of 30 (41.7%) ECG leads showed a difference in EVA (marked difference in 20.8%, slight difference in 20.8%). In our experience, additional anodal capture by the proximal LV ring during LV pacing is provable in most recipients of a resynchronization device equipped with a multipolar LV lead. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Enhancement of low sampling frequency recordings for ECG biometric matching using interpolation.
Sidek, Khairul Azami; Khalil, Ibrahim
2013-01-01
Electrocardiogram (ECG) based biometric matching suffers from high misclassification error with lower sampling frequency data. This situation may lead to an unreliable and vulnerable identity authentication process in high security applications. In this paper, quality enhancement techniques for ECG data with low sampling frequency has been proposed for person identification based on piecewise cubic Hermite interpolation (PCHIP) and piecewise cubic spline interpolation (SPLINE). A total of 70 ECG recordings from 4 different public ECG databases with 2 different sampling frequencies were applied for development and performance comparison purposes. An analytical method was used for feature extraction. The ECG recordings were segmented into two parts: the enrolment and recognition datasets. Three biometric matching methods, namely, Cross Correlation (CC), Percent Root-Mean-Square Deviation (PRD) and Wavelet Distance Measurement (WDM) were used for performance evaluation before and after applying interpolation techniques. Results of the experiments suggest that biometric matching with interpolated ECG data on average achieved higher matching percentage value of up to 4% for CC, 3% for PRD and 94% for WDM. These results are compared with the existing method when using ECG recordings with lower sampling frequency. Moreover, increasing the sample size from 56 to 70 subjects improves the results of the experiment by 4% for CC, 14.6% for PRD and 0.3% for WDM. Furthermore, higher classification accuracy of up to 99.1% for PCHIP and 99.2% for SPLINE with interpolated ECG data as compared of up to 97.2% without interpolation ECG data verifies the study claim that applying interpolation techniques enhances the quality of the ECG data. Crown Copyright © 2012. Published by Elsevier Ireland Ltd. All rights reserved.
Near Field Communication-based telemonitoring with integrated ECG recordings
Morak, J.; Kumpusch, H.; Hayn, D.; Leitner, M.; Scherr, D.; Fruhwald, F.M.; Schreier, G.
2011-01-01
Objectives Telemonitoring of vital signs is an established option in treatment of patients with chronic heart failure (CHF). In order to allow for early detection of atrial fibrillation (AF) which is highly prevalent in the CHF population telemonitoring programs should include electrocardiogram (ECG) signals. It was therefore the aim to extend our current home monitoring system based on mobile phones and Near Field Communication technology (NFC) to enable patients acquiring their ECG signals autonomously in an easy-to-use way. Methods We prototypically developed a sensing device for the concurrent acquisition of blood pressure and ECG signals. The design of the device equipped with NFC technology and Bluetooth allowed for intuitive interaction with a mobile phone based patient terminal. This ECG monitoring system was evaluated in the course of a clinical pilot trial to assess the system’s technical feasibility, usability and patient’s adherence to twice daily usage. Results 21 patients (4f, 54 ± 14 years) suffering from CHF were included in the study and were asked to transmit two ECG recordings per day via the telemonitoring system autonomously over a monitoring period of seven days. One patient dropped out from the study. 211 data sets were transmitted over a cumulative monitoring period of 140 days (overall adherence rate 82.2%). 55% and 8% of the transmitted ECG signals were sufficient for ventricular and atrial rhythm assessment, respectively. Conclusions Although ECG signal quality has to be improved for better AF detection the developed communication design of joining Bluetooth and NFC technology in our telemonitoring system allows for ambulatory ECG acquisition with high adherence rates and system usability in heart failure patients. PMID:23616890
Sakai, Toshiaki; Nishiyama, Osamu; Onodera, Masayuki; Matsuda, Shigekatsu; Wakisawa, Shinobu; Nakamura, Motoyuki; Morino, Yoshihiro; Itoh, Tomonori
2018-05-24
The purposes of this study were to create a new flow-chart of prehospital electrocardiography (ECG)-transmission, evaluate its predictive ability for ST-elevation myocardial infarction (STEMI) and shorten door-to-balloon time (DTBT). The new transmission flow-chart was created using symptoms from previous medical records of STEMI patients. A total of 4090 consecutive patients transferred emergently to our hospital were divided into two groups: those in ambulances with an ECG-transmission device with the new flow-chart (ECGT-FC) and those transferred without an ECG-transmission device (non-ECGT) groups. A STEMI group comprising walk-in patients during the same period was used as a control group. The predictive ability of STEMI and the effectiveness of shortening the DTBT by the new flow-chart of ECG-transmission was evaluated. In the ECGT-FC group, the prevalence of STEMI in the ECG-transmission by the new flow-chart were significantly higher than in the non-ECG-transmission patients (6.71% vs. 0.19%; p<0.001). The sensitivity and specificity of the new ECG-transmission flow-chart were 83.3% and 88.1%, respectively. The median DTBT was significantly shortened (p=0.045) and the prevalence of DTBT<90min was significantly higher in the ECGT-FC group (p=0.018) than the other groups. The sensitivity and specificity of the new flow-chart for ECG-transmission were high. The new flow-chart combined with an ECG-transmission device could detect STEMI efficiently and shorten DTBT. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Influence of ECG measurement accuracy on ECG diagnostic statements.
Zywietz, C; Celikag, D; Joseph, G
1996-01-01
Computer analysis of electrocardiograms (ECGs) provides a large amount of ECG measurement data, which may be used for diagnostic classification and storage in ECG databases. Until now, neither error limits for ECG measurements have been specified nor has their influence on diagnostic statements been systematically investigated. An analytical method is presented to estimate the influence of measurement errors on the accuracy of diagnostic ECG statements. Systematic (offset) errors will usually result in an increase of false positive or false negative statements since they cause a shift of the working point on the receiver operating characteristics curve. Measurement error dispersion broadens the distribution function of discriminative measurement parameters and, therefore, usually increases the overlap between discriminative parameters. This results in a flattening of the receiver operating characteristics curve and an increase of false positive and false negative classifications. The method developed has been applied to ECG conduction defect diagnoses by using the proposed International Electrotechnical Commission's interval measurement tolerance limits. These limits appear too large because more than 30% of false positive atrial conduction defect statements and 10-18% of false intraventricular conduction defect statements could be expected due to tolerated measurement errors. To assure long-term usability of ECG measurement databases, it is recommended that systems provide its error tolerance limits obtained on a defined test set.
Real-Time Analytics for the Healthcare Industry: Arrhythmia Detection.
Agneeswaran, Vijay Srinivas; Mukherjee, Joydeb; Gupta, Ashutosh; Tonpay, Pranay; Tiwari, Jayati; Agarwal, Nitin
2013-09-01
It is time for the healthcare industry to move from the era of "analyzing our health history" to the age of "managing the future of our health." In this article, we illustrate the importance of real-time analytics across the healthcare industry by providing a generic mechanism to reengineer traditional analytics expressed in the R programming language into Storm-based real-time analytics code. This is a powerful abstraction, since most data scientists use R to write the analytics and are not clear on how to make the data work in real-time and on high-velocity data. Our paper focuses on the applications necessary to a healthcare analytics scenario, specifically focusing on the importance of electrocardiogram (ECG) monitoring. A physician can use our framework to compare ECG reports by categorization and consequently detect Arrhythmia. The framework can read the ECG signals and uses a machine learning-based categorizer that runs within a Storm environment to compare different ECG signals. The paper also presents some performance studies of the framework to illustrate the throughput and accuracy trade-off in real-time analytics.
Wolff-Parkinson-white syndrome mimics a conduction disease.
Marrakchi, S; Kammoun, I; Kachboura, S
2014-01-01
Background. It is important to recognise Wolff-Parkinson-White (WPW) syndrome in electrocardiograms (ECG), as it may mimic ischaemic heart disease, ventricular hypertrophy, and bundle branch block. Recognising WPW syndrome allows for risk stratification, the identification of associated conditions, and the institution of appropriate management. Objective. The present case showed that electrophysiological study is indicated in patients with abnormal ECG and syncope. Case Report. A 40-year-old man with Wolff-Parkinson-White syndrome was presented to emergency with syncope. A baseline ECG was a complete right branch block and posterior left hemiblock. He was admitted to the cardiac care unit for pacemaker implantation. The atypical figure of complete right branch block and posterior left hemiblock was thought to be a "false positive" of conduction abnormality. But the long anterograde refractory period of the both accessory pathway and atrioventricular conduction may cause difficulty in diagnosing Wolff-Parkinson-White syndrome, Conclusion. A Wolff-Parkinson-White Syndrome may mimic a conduction disease. No reliable algorithm exists for making an ECG diagnosis of a preexcitation syndrome with conduction disorders. This can lead to diagnostic and therapeutic dilemmas in the context of syncope.
Hwang, Bosun; You, Jiwoo; Vaessen, Thomas; Myin-Germeys, Inez; Park, Cheolsoo; Zhang, Byoung-Tak
2018-02-08
Stress recognition using electrocardiogram (ECG) signals requires the intractable long-term heart rate variability (HRV) parameter extraction process. This study proposes a novel deep learning framework to recognize the stressful states, the Deep ECGNet, using ultra short-term raw ECG signals without any feature engineering methods. The Deep ECGNet was developed through various experiments and analysis of ECG waveforms. We proposed the optimal recurrent and convolutional neural networks architecture, and also the optimal convolution filter length (related to the P, Q, R, S, and T wave durations of ECG) and pooling length (related to the heart beat period) based on the optimization experiments and analysis on the waveform characteristics of ECG signals. The experiments were also conducted with conventional methods using HRV parameters and frequency features as a benchmark test. The data used in this study were obtained from Kwangwoon University in Korea (13 subjects, Case 1) and KU Leuven University in Belgium (9 subjects, Case 2). Experiments were designed according to various experimental protocols to elicit stressful conditions. The proposed framework to recognize stress conditions, the Deep ECGNet, outperformed the conventional approaches with the highest accuracy of 87.39% for Case 1 and 73.96% for Case 2, respectively, that is, 16.22% and 10.98% improvements compared with those of the conventional HRV method. We proposed an optimal deep learning architecture and its parameters for stress recognition, and the theoretical consideration on how to design the deep learning structure based on the periodic patterns of the raw ECG data. Experimental results in this study have proved that the proposed deep learning model, the Deep ECGNet, is an optimal structure to recognize the stress conditions using ultra short-term ECG data.
Classification of arrhythmia using hybrid networks.
Haseena, Hassan H; Joseph, Paul K; Mathew, Abraham T
2011-12-01
Reliable detection of arrhythmias based on digital processing of Electrocardiogram (ECG) signals is vital in providing suitable and timely treatment to a cardiac patient. Due to corruption of ECG signals with multiple frequency noise and presence of multiple arrhythmic events in a cardiac rhythm, computerized interpretation of abnormal ECG rhythms is a challenging task. This paper focuses a Fuzzy C- Mean (FCM) clustered Probabilistic Neural Network (PNN) and Multi Layered Feed Forward Network (MLFFN) for the discrimination of eight types of ECG beats. Parameters such as fourth order Auto Regressive (AR) coefficients along with Spectral Entropy (SE) are extracted from each ECG beat and feature reduction has been carried out using FCM clustering. The cluster centers form the input of neural network classifiers. The extensive analysis of Massachusetts Institute of Technology- Beth Israel Hospital (MIT-BIH) arrhythmia database shows that FCM clustered PNNs is superior in cardiac arrhythmia classification than FCM clustered MLFFN with an overall accuracy of 99.05%, 97.14%, respectively.
FPGA Implementation of Heart Rate Monitoring System.
Panigrahy, D; Rakshit, M; Sahu, P K
2016-03-01
This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.
Rauf, Zubair; O'Brien, Ediri; Stampalija, Tamara; Ilioniu, Florin P; Lavender, Tina; Alfirevic, Zarko
2011-01-01
To evaluate the feasibility of continuous telemetric trans-abdominal fetal electrocardiogram (a-fECG) in women undergoing labour induction at home. Low risk women with singleton term pregnancy undergoing labour induction with retrievable, slow-release dinoprostone pessaries (n = 70) were allowed home for up to 24 hours, while a-fECG and uterine activity were monitored in hospital via wireless technology. Semi-structured diaries were analysed using a combined descriptive and interpretive approach. 62/70 women (89%) had successful home monitoring; 8 women (11%) were recalled because of signal loss. Home monitoring lasted between 2-22 hours (median 10 hours). Good quality signal was achieved most of the time (86%, SD 10%). 3 women were recalled back to hospital for suspicious a-fECG. In 2 cases suspicious a-fECG persisted, requiring Caesarean section after recall to hospital. 48/51 women who returned the diary coped well (94%); 46/51 were satisfied with home monitoring (90%). Continuous telemetric trans-abdominal fetal ECG monitoring of ambulatory women undergoing labour induction is feasible and acceptable to women.
NASA Astrophysics Data System (ADS)
He, Runnan; Wang, Kuanquan; Li, Qince; Yuan, Yongfeng; Zhao, Na; Liu, Yang; Zhang, Henggui
2017-12-01
Cardiovascular diseases are associated with high morbidity and mortality. However, it is still a challenge to diagnose them accurately and efficiently. Electrocardiogram (ECG), a bioelectrical signal of the heart, provides crucial information about the dynamical functions of the heart, playing an important role in cardiac diagnosis. As the QRS complex in ECG is associated with ventricular depolarization, therefore, accurate QRS detection is vital for interpreting ECG features. In this paper, we proposed a real-time, accurate, and effective algorithm for QRS detection. In the algorithm, a proposed preprocessor with a band-pass filter was first applied to remove baseline wander and power-line interference from the signal. After denoising, a method combining K-Nearest Neighbor (KNN) and Particle Swarm Optimization (PSO) was used for accurate QRS detection in ECGs with different morphologies. The proposed algorithm was tested and validated using 48 ECG records from MIT-BIH arrhythmia database (MITDB), achieved a high averaged detection accuracy, sensitivity and positive predictivity of 99.43, 99.69, and 99.72%, respectively, indicating a notable improvement to extant algorithms as reported in literatures.
From Pacemaker to Wearable: Techniques for ECG Detection Systems.
Kumar, Ashish; Komaragiri, Rama; Kumar, Manjeet
2018-01-11
With the alarming rise in the deaths due to cardiovascular diseases (CVD), present medical research scenario places notable importance on techniques and methods to detect CVDs. As adduced by world health organization, technological proceeds in the field of cardiac function assessment have become the nucleus and heart of all leading research studies in CVDs in which electrocardiogram (ECG) analysis is the most functional and convenient tool used to test the range of heart-related irregularities. Most of the approaches present in the literature of ECG signal analysis consider noise removal, rhythm-based analysis, and heartbeat detection to improve the performance of a cardiac pacemaker. Advancements achieved in the field of ECG segments detection and beat classification have a limited evaluation and still require clinical approvals. In this paper, approaches on techniques to implement on-chip ECG detector for a cardiac pacemaker system are discussed. Moreover, different challenges regarding the ECG signal morphology analysis deriving from medical literature is extensively reviewed. It is found that robustness to noise, wavelet parameter choice, numerical efficiency, and detection performance are essential performance indicators required by a state-of-the-art ECG detector. Furthermore, many algorithms described in the existing literature are not verified using ECG data from the standard databases. Some ECG detection algorithms show very high detection performance with the total number of detected QRS complexes. However, the high detection performance of the algorithm is verified using only a few datasets. Finally, gaps in current advancements and testing are identified, and the primary challenge remains to be implementing bullseye test for morphology analysis evaluation.
Cardiac investigation in patients with diabetes.
Tardif, Jean-Claude
2006-02-01
Most patients with type 2 diabetes die from heart disease. Screening for the presence of myocardial ischemia is of clinical importance in the management of this population. The pain response to ischemia can be either absent or blunted in diabetes, resulting in the absence of symptoms or an atypical presentation. Exercise electrocardiogram (ECG) should be the initial test in men who are able to exercise and have a normal resting ECG. Stress cardiac imaging should be the initial test in diabetic men with an abnormal resting ECG or who are not able to exercise. More widespread use of cardiac imaging is probably justified in diabetic women and patients with suspected coronary artery disease. Official guidelines for appropriate and cost-effective cardiac investigation should help physicians manage diabetic patients.
Mason, Jay W; Hancock, E William; Gettes, Leonard S
2007-03-01
This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.
ECG Holter monitor with alert system and mobile application
NASA Astrophysics Data System (ADS)
Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.
2016-05-01
This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.
Evaluation of cardiac signals using discrete wavelet transform with MATLAB graphical user interface.
John, Agnes Aruna; Subramanian, Aruna Priyadharshni; Jaganathan, Saravana Kumar; Sethuraman, Balasubramanian
2015-01-01
To process the electrocardiogram (ECG) signals using MATLAB-based graphical user interface (GUI) and to classify the signals based on heart rate. The subject condition was identified using R-peak detection based on discrete wavelet transform followed by a Bayes classifier that classifies the ECG signals. The GUI was designed to display the ECG signal plot. Obtained from MIT database 18 patients had normal heart rate and 9 patients had abnormal heart rate; 14.81% of the patients suffered from tachycardia and 18.52% of the patients have bradycardia. The proposed GUI display was found useful to analyze the digitized ECG signal by a non-technical user and may help in diagnostics. Further improvement can be done by employing field programmable gate array for the real time processing of cardiac signals. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
An automatic classifier of emotions built from entropy of noise.
Ferreira, Jacqueline; Brás, Susana; Silva, Carlos F; Soares, Sandra C
2017-04-01
The electrocardiogram (ECG) signal has been widely used to study the physiological substrates of emotion. However, searching for better filtering techniques in order to obtain a signal with better quality and with the maximum relevant information remains an important issue for researchers in this field. Signal processing is largely performed for ECG analysis and interpretation, but this process can be susceptible to error in the delineation phase. In addition, it can lead to the loss of important information that is usually considered as noise and, consequently, discarded from the analysis. The goal of this study was to evaluate if the ECG noise allows for the classification of emotions, while using its entropy as an input in a decision tree classifier. We collected the ECG signal from 25 healthy participants while they were presented with videos eliciting negative (fear and disgust) and neutral emotions. The results indicated that the neutral condition showed a perfect identification (100%), whereas the classification of negative emotions indicated good identification performances (60% of sensitivity and 80% of specificity). These results suggest that the entropy of noise contains relevant information that can be useful to improve the analysis of the physiological correlates of emotion. © 2016 Society for Psychophysiological Research.
Koski, Antti; Tossavainen, Timo; Juhola, Martti
2004-01-01
Electrocardiogram (ECG) signals are the most prominent biomedical signal type used in clinical medicine. Their compression is important and widely researched in the medical informatics community. In the previous literature compression efficacy has been investigated only in the context of how much known or developed methods reduced the storage required by compressed forms of original ECG signals. Sometimes statistical signal evaluations based on, for example, root mean square error were studied. In previous research we developed a refined method for signal compression and tested it jointly with several known techniques for other biomedical signals. Our method of so-called successive approximation quantization used with wavelets was one of the most successful in those tests. In this paper, we studied to what extent these lossy compression methods altered values of medical parameters (medical information) computed from signals. Since the methods are lossy, some information is lost due to the compression when a high enough compression ratio is reached. We found that ECG signals sampled at 400 Hz could be compressed to one fourth of their original storage space, but the values of their medical parameters changed less than 5% due to compression, which indicates reliable results.
Ryabykina, G V; Sozykin, A V; Dobrovolskaya, S V
2007-07-01
The aim of this study was to compare electrocardiogram (ECG)-12 dynamics depending on the methods of facilitated and primary angioplasty in patients with acute coronary syndrome. The ECG changes in 81 patients - 73 patients with acute myocardial infarction and 8 patients with unstable angina pectoris - were studied. The ECG analysis before reperfusion therapy and after angioplasty included: dynamics of summary elevation (Sigma ST+) and depression (Sigma ST-) of ST segment and changes of summary value of R waves (Sigma R) in 12 leads. The results were estimated with consideration for the length of the period from the beginning of pain syndrome till treatment and topics of the infraction-related artery. According to our data, there was no difference between facilitated and primary transluminal coronary angioplasty in their effect on focal myocardial variation dynamics and the size of peri-infarction zone. A reliable decrease in elevation and depression of ST segment was observed in reperfusion therapy not later than 6 hours after the beginning of pain syndrome. When reperfusion therapy is begun later, dynamics of summary values of ST segment elevation and depression before and after treatment are not reliable.
Real-time magnetic resonance imaging of cardiac function and flow—recent progress
Zhang, Shuo; Joseph, Arun A.; Voit, Dirk; Schaetz, Sebastian; Merboldt, Klaus-Dietmar; Unterberg-Buchwald, Christina; Hennemuth, Anja; Lotz, Joachim
2014-01-01
Cardiac structure, function and flow are most commonly studied by ultrasound, X-ray and magnetic resonance imaging (MRI) techniques. However, cardiovascular MRI is hitherto limited to electrocardiogram (ECG)-synchronized acquisitions and therefore often results in compromised quality for patients with arrhythmias or inabilities to comply with requested protocols—especially with breath-holding. Recent advances in the development of novel real-time MRI techniques now offer dynamic imaging of the heart and major vessels with high spatial and temporal resolution, so that examinations may be performed without the need for ECG synchronization and during free breathing. This article provides an overview of technical achievements, physiological validations, preliminary patient studies and translational aspects for a future clinical scenario of cardiovascular MRI in real time. PMID:25392819
Electrocardiographic interpretation skills of cardiology residents: are they competent?
Sibbald, Matthew; Davies, Edward G; Dorian, Paul; Yu, Eric H C
2014-12-01
Achieving competency at electrocardiogram (ECG) interpretation among cardiology subspecialty residents has traditionally focused on interpreting a target number of ECGs during training. However, there is little evidence to support this approach. Further, there are no data documenting the competency of ECG interpretation skills among cardiology residents, who become de facto the gold standard in their practice communities. We tested 29 Cardiology residents from all 3 years in a large training program using a set of 20 ECGs collected from a community cardiology practice over a 1-month period. Residents interpreted half of the ECGs using a standard analytic framework, and half using their own approach. Residents were scored on the number of correct and incorrect diagnoses listed. Overall diagnostic accuracy was 58%. Of 6 potentially life-threatening diagnoses, residents missed 36% (123 of 348) including hyperkalemia (81%), long QT (52%), complete heart block (35%), and ventricular tachycardia (19%). Residents provided additional inappropriate diagnoses on 238 ECGs (41%). Diagnostic accuracy was similar between ECGs interpreted using an analytic framework vs ECGs interpreted without an analytic framework (59% vs 58%; F(1,1333) = 0.26; P = 0.61). Cardiology resident proficiency at ECG interpretation is suboptimal. Despite the use of an analytic framework, there remain significant deficiencies in ECG interpretation among Cardiology residents. A more systematic method of addressing these important learning gaps is urgently needed. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
MS-QI: A Modulation Spectrum-Based ECG Quality Index for Telehealth Applications.
Tobon V, Diana P; Falk, Tiago H; Maier, Martin
2016-08-01
As telehealth applications emerge, the need for accurate and reliable biosignal quality indices has increased. One typical modality used in remote patient monitoring is the electrocardiogram (ECG), which is inherently susceptible to several different noise sources, including environmental (e.g., powerline interference), experimental (e.g., movement artifacts), and physiological (e.g., muscle and breathing artifacts). Accurate measurement of ECG quality can allow for automated decision support systems to make intelligent decisions about patient conditions. This is particularly true for in-home monitoring applications, where the patient is mobile and the ECG signal can be severely corrupted by movement artifacts. In this paper, we propose an innovative ECG quality index based on the so-called modulation spectral signal representation. The representation quantifies the rate of change of ECG spectral components, which are shown to be different from the rate of change of typical ECG noise sources. The proposed modulation spectral-based quality index, MS-QI, was tested on 1) synthetic ECG signals corrupted by varying levels of noise, 2) single-lead recorded data using the Hexoskin garment during three activity levels (sitting, walking, running), 3) 12-lead recorded data using conventional ECG machines (Computing in Cardiology 2011 dataset), and 4) two-lead ambulatory ECG recorded from arrhythmia patients (MIT-BIH Arrhythmia Database). Experimental results showed the proposed index outperforming two conventional benchmark quality measures, particularly in the scenarios involving recorded data in real-world environments.
Kim, Chul-Hee; Ko, Kwan-Ho; Park, Seong-Wook; Park, Joong-Yeol; Lee, Ki-Up
2010-01-01
Background/Aims Resting electrocardiogram (ECG) abnormalities have been strongly associated with cardiovascular disease mortality. Little is known, however, about the association between individual components of metabolic syndrome and ECG abnormalities, especially in Asian populations. Methods We examined clinical and laboratory data from 31,399 subjects (age 20 to 89 years) who underwent medical check-ups. ECG abnormalities were divided into minor and major abnormalities based on Novacode criteria. Ischemic ECG findings were separately identified and analyzed. Results The overall prevalence rates of ECG abnormalities were significantly higher in subjects with than in those without metabolic syndrome (p < 0.01). Ischemic ECG was strongly associated with metabolic syndrome in all age groups of both sexes, except for younger women. In multiple logistic regression analysis, metabolic syndrome was independently associated with ischemic ECG (odds ratio, 2.30 [2.04 to 2.62]; p < 0.01), after adjusting for sex, age, smoking, and family history of cardiovascular disease. Of the metabolic syndrome components, hyperglycemia in younger subjects and hypertension in elderly subjects were major factors for ischemic ECG changes, whereas hypertriglyceridemia was not an independent risk factor in any age group. The association between ischemic ECG findings and central obesity was weaker in women than in men. Conclusions Metabolic syndrome was strongly associated with ECG abnormalities, especially ischemic ECG findings, in Koreans. The association between each component of metabolic syndrome and ECG abnormalities varied according to age and sex. PMID:20526391
Dores, Hélder; Malhotra, Aneil; Sheikh, Nabeel; Millar, Lynne; Dhutia, Harshil; Narain, Rajay; Merghani, Ahmed; Papadakis, Michael; Sharma, Sanjay
2016-11-01
Athletes can exhibit abnormal electrocardiogram (ECG) phenotypes that require further evaluation prior to competition. These are apparently more prevalent in high-intensity endurance sports. The purpose of this study was to assess the association between ECG findings in athletes and intensity of sport and level of competition. A cohort of 3423 competitive athletes had their ECGs assessed according to the Seattle criteria (SC). The presence of abnormal ECGs was correlated with: (1) intensity of sport (low/moderate vs. at least one high static or dynamic component); (2) competitive level (regional vs. national/international); (3) training volume (≤20 vs. >20 hours/week); (4) type of sport (high dynamic vs. high static component). The same endpoints were studied according to the 'Refined Criteria' (RC). Abnormal ECGs according to the SC were present in 225 (6.6%) athletes, more frequently in those involved in high-intensity sports (8.0% vs. 5.4%; p=0.002), particularly in dynamic sports, and competing at national/international level (7.1% vs. 4.9%; p=0.028). Training volume was not significantly associated with abnormal ECGs. By multivariate analysis, high-intensity sport (OR 1.55, 1.18-2.03; p=0.002) and national/international level (OR 1.50, 95% CI 1.04-2.14; p=0.027) were independent predictors of abnormal ECGs, and these variables, when combined, doubled the prevalence of this finding. According to the RC, abnormal ECGs decreased to 103 (3.0%), but were also more frequent in high-intensity sports (4.2% vs. 2.0%; p<0.001). There is a positive correlation between higher intensity of sports and increased prevalence of ECG abnormalities. This relationship persists with the use of more restrictive criteria for ECG interpretation, although the number of abnormal ECGs is lower. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Evans, Grahame F; Shirk, Arianna; Muturi, Peter; Soliman, Elsayed Z
2017-12-01
Screening for atrial fibrillation (AF), a major risk factor for stroke that is on the rise in Africa, is becoming increasingly critical. This study sought to examine the feasibility of using mobile electrocardiogram (ECG) recording technology to detect AF. In this prospective observational study, we used a mobile ECG recorder to screen 50 African adults (66% women; mean age 54.3 ± 20.5 years) attending Kijabe Hospital (Kijabe, Kenya). Five hospital health providers involved in this study's data collection process also completed a self-administered survey to obtain information on their access to the Internet and mobile devices, both factors necessary to implement ECG mobile technology. Outcome measures included feasibility (completion of the study and recruitment of the patients on the planned study time frame) and the yield of the screening by the mobile ECG technology (ability to detect previously undiagnosed AF). Patients were recruited in a 2-week period as planned; only 1 of the 51 patients approached refused to participate (98% acceptance rate). All of the 50 patients who agreed to participate completed the test and produced readable ECGs (100% study completion rate). ECG tracings of 4 of the 50 patients who completed the study showed AF (8% AF yield), and none had been previously diagnosed with AF. When asked about continuous access to Internet and personal mobile devices, almost all of the health care providers surveyed answered affirmatively. Using mobile ECG technology in screening for AF in low-resource settings is feasible, and can detect a significant proportion of AF cases that will otherwise go undiagnosed. Further study is needed to examine the cost-effectiveness of this approach for detection of AF and its effect on reducing the risk of stroke in developing countries. Copyright © 2016 World Heart Federation (Geneva). Published by Elsevier B.V. All rights reserved.
Mild-to-moderate exercise is often used to stress the cardiovascular (CV) system of patients while monitoring them for electrocardiogram (ECG) abnormalities that may indicate underlying CV disease. We previously demonstrated that dobutamine, which increases heart rate (HR) and co...
Panigrahy, D; Sahu, P K
2017-03-01
This paper proposes a five-stage based methodology to extract the fetal electrocardiogram (FECG) from the single channel abdominal ECG using differential evolution (DE) algorithm, extended Kalman smoother (EKS) and adaptive neuro fuzzy inference system (ANFIS) framework. The heart rate of the fetus can easily be detected after estimation of the fetal ECG signal. The abdominal ECG signal contains fetal ECG signal, maternal ECG component, and noise. To estimate the fetal ECG signal from the abdominal ECG signal, removal of the noise and the maternal ECG component presented in it is necessary. The pre-processing stage is used to remove the noise from the abdominal ECG signal. The EKS framework is used to estimate the maternal ECG signal from the abdominal ECG signal. The optimized parameters of the maternal ECG components are required to develop the state and measurement equation of the EKS framework. These optimized maternal ECG parameters are selected by the differential evolution algorithm. The relationship between the maternal ECG signal and the available maternal ECG component in the abdominal ECG signal is nonlinear. To estimate the actual maternal ECG component present in the abdominal ECG signal and also to recognize this nonlinear relationship the ANFIS is used. Inputs to the ANFIS framework are the output of EKS and the pre-processed abdominal ECG signal. The fetal ECG signal is computed by subtracting the output of ANFIS from the pre-processed abdominal ECG signal. Non-invasive fetal ECG database and set A of 2013 physionet/computing in cardiology challenge database (PCDB) are used for validation of the proposed methodology. The proposed methodology shows a sensitivity of 94.21%, accuracy of 90.66%, and positive predictive value of 96.05% from the non-invasive fetal ECG database. The proposed methodology also shows a sensitivity of 91.47%, accuracy of 84.89%, and positive predictive value of 92.18% from the set A of PCDB.
Cairns, Andrew W; Bond, Raymond R; Finlay, Dewar D; Breen, Cathal; Guldenring, Daniel; Gaffney, Robert; Gallagher, Anthony G; Peace, Aaron J; Henn, Pat
2016-12-01
The 12-lead Electrocardiogram (ECG) presents a plethora of information and demands extensive knowledge and a high cognitive workload to interpret. Whilst the ECG is an important clinical tool, it is frequently incorrectly interpreted. Even expert clinicians are known to impulsively provide a diagnosis based on their first impression and often miss co-abnormalities. Given it is widely reported that there is a lack of competency in ECG interpretation, it is imperative to optimise the interpretation process. Predominantly the ECG interpretation process remains a paper based approach and whilst computer algorithms are used to assist interpreters by providing printed computerised diagnoses, there are a lack of interactive human-computer interfaces to guide and assist the interpreter. An interactive computing system was developed to guide the decision making process of a clinician when interpreting the ECG. The system decomposes the interpretation process into a series of interactive sub-tasks and encourages the clinician to systematically interpret the ECG. We have named this model 'Interactive Progressive based Interpretation' (IPI) as the user cannot 'progress' unless they complete each sub-task. Using this model, the ECG is segmented into five parts and presented over five user interfaces (1: Rhythm interpretation, 2: Interpretation of the P-wave morphology, 3: Limb lead interpretation, 4: QRS morphology interpretation with chest lead and rhythm strip presentation and 5: Final review of 12-lead ECG). The IPI model was implemented using emerging web technologies (i.e. HTML5, CSS3, AJAX, PHP and MySQL). It was hypothesised that this system would reduce the number of interpretation errors and increase diagnostic accuracy in ECG interpreters. To test this, we compared the diagnostic accuracy of clinicians when they used the standard approach (control cohort) with clinicians who interpreted the same ECGs using the IPI approach (IPI cohort). For the control cohort, the (mean; standard deviation; confidence interval) of the ECG interpretation accuracy was (45.45%; SD=18.1%; CI=42.07, 48.83). The mean ECG interpretation accuracy rate for the IPI cohort was 58.85% (SD=42.4%; CI=49.12, 68.58), which indicates a positive mean difference of 13.4%. (CI=4.45, 22.35) An N-1 Chi-square test of independence indicated a 92% chance that the IPI cohort will have a higher accuracy rate. Interpreter self-rated confidence also increased between cohorts from a mean of 4.9/10 in the control cohort to 6.8/10 in the IPI cohort (p=0.06). Whilst the IPI cohort had greater diagnostic accuracy, the duration of ECG interpretation was six times longer when compared to the control cohort. We have developed a system that segments and presents the ECG across five graphical user interfaces. Results indicate that this approach improves diagnostic accuracy but with the expense of time, which is a valuable resource in medical practice. Copyright © 2016 Elsevier Inc. All rights reserved.
Fast multi-scale feature fusion for ECG heartbeat classification
NASA Astrophysics Data System (ADS)
Ai, Danni; Yang, Jian; Wang, Zeyu; Fan, Jingfan; Ai, Changbin; Wang, Yongtian
2015-12-01
Electrocardiogram (ECG) is conducted to monitor the electrical activity of the heart by presenting small amplitude and duration signals; as a result, hidden information present in ECG data is difficult to determine. However, this concealed information can be used to detect abnormalities. In our study, a fast feature-fusion method of ECG heartbeat classification based on multi-linear subspace learning is proposed. The method consists of four stages. First, baseline and high frequencies are removed to segment heartbeat. Second, as an extension of wavelets, wavelet-packet decomposition is conducted to extract features. With wavelet-packet decomposition, good time and frequency resolutions can be provided simultaneously. Third, decomposed confidences are arranged as a two-way tensor, in which feature fusion is directly implemented with generalized N dimensional ICA (GND-ICA). In this method, co-relationship among different data information is considered, and disadvantages of dimensionality are prevented; this method can also be used to reduce computing compared with linear subspace-learning methods (PCA). Finally, support vector machine (SVM) is considered as a classifier in heartbeat classification. In this study, ECG records are obtained from the MIT-BIT arrhythmia database. Four main heartbeat classes are used to examine the proposed algorithm. Based on the results of five measurements, sensitivity, positive predictivity, accuracy, average accuracy, and t-test, our conclusion is that a GND-ICA-based strategy can be used to provide enhanced ECG heartbeat classification. Furthermore, large redundant features are eliminated, and classification time is reduced.
Billeci, Lucia; Varanini, Maurizio
2017-01-01
The non-invasive fetal electrocardiogram (fECG) technique has recently received considerable interest in monitoring fetal health. The aim of our paper is to propose a novel fECG algorithm based on the combination of the criteria of independent source separation and of a quality index optimization (ICAQIO-based). The algorithm was compared with two methods applying the two different criteria independently—the ICA-based and the QIO-based methods—which were previously developed by our group. All three methods were tested on the recently implemented Fetal ECG Synthetic Database (FECGSYNDB). Moreover, the performance of the algorithm was tested on real data from the PhysioNet fetal ECG Challenge 2013 Database. The proposed combined method outperformed the other two algorithms on the FECGSYNDB (ICAQIO-based: 98.78%, QIO-based: 97.77%, ICA-based: 97.61%). Significant differences were obtained in particular in the conditions when uterine contractions and maternal and fetal ectopic beats occurred. On the real data, all three methods obtained very high performances, with the QIO-based method proving slightly better than the other two (ICAQIO-based: 99.38%, QIO-based: 99.76%, ICA-based: 99.37%). The findings from this study suggest that the proposed method could potentially be applied as a novel algorithm for accurate extraction of fECG, especially in critical recording conditions. PMID:28509860
ECG signal quality during arrhythmia and its application to false alarm reduction.
Behar, Joachim; Oster, Julien; Li, Qiao; Clifford, Gari D
2013-06-01
An automated algorithm to assess electrocardiogram (ECG) quality for both normal and abnormal rhythms is presented for false arrhythmia alarm suppression of intensive care unit (ICU) monitors. A particular focus is given to the quality assessment of a wide variety of arrhythmias. Data from three databases were used: the Physionet Challenge 2011 dataset, the MIT-BIH arrhythmia database, and the MIMIC II database. The quality of more than 33 000 single-lead 10 s ECG segments were manually assessed and another 12 000 bad-quality single-lead ECG segments were generated using the Physionet noise stress test database. Signal quality indices (SQIs) were derived from the ECGs segments and used as the inputs to a support vector machine classifier with a Gaussian kernel. This classifier was trained to estimate the quality of an ECG segment. Classification accuracies of up to 99% on the training and test set were obtained for normal sinus rhythm and up to 95% for arrhythmias, although performance varied greatly depending on the type of rhythm. Additionally, the association between 4050 ICU alarms from the MIMIC II database and the signal quality, as evaluated by the classifier, was studied. Results suggest that the SQIs should be rhythm specific and that the classifier should be trained for each rhythm call independently. This would require a substantially increased set of labeled data in order to train an accurate algorithm.
Lenoir, Augustin; Trachsel, Dagmar S; Younes, Mohamed; Barrey, Eric; Robert, Céline
2017-01-01
Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays, the RR intervals can be obtained through two different techniques: a heart rate meter (HRM) or an electrocardiogram (ECG). The agreement and reliability of these devices has not been fully assessed, especially for recordings during exercise. The purpose of this study was to assess the agreement of two commercially available devices using the two mentioned techniques (HRM vs ECG) for HRV analysis during a standardized exercise test. Simultaneous recordings obtained during light exercise and during canter with both devices were available for 36 horses. Data were compared using a Bland-Altman analysis and the Lin's coefficient. The agreement between the assessed HRV measures from the data obtained from the ECG and HRM was acceptable only for the mean RR interval and the mean heart rate. For the other studied measures (SDNN, root mean square of successive differences, SD1, SD2, low frequency, high frequency), the agreement between the devices was too poor for them to be considered as interchangeable in these recording conditions. The agreement tended also to be worse when speed of the exercise increased. Therefore, it is necessary to be careful when interpreting and comparing results of HRV analysis during exercise, as the results will depend upon recording devices. Furthermore, corrections and data processing included in the software of the devices affect largely the output used in the subsequent HRV analysis; this must be considered in the choice of the device.
E-learning and near-peer teaching in electrocardiogram education: a randomised trial.
Davies, Andrew; Macleod, Rachael; Bennett-Britton, Ian; McElnay, Philip; Bakhbakhi, Danya; Sansom, Jane
2016-06-01
Near-peer teaching and electronic learning (e-learning) are two effective modern teaching styles. Near-peer sessions provide a supportive learning environment that benefits both the students and the tutor. E-learning resources are flexible and easily distributed. Careful construction and regular editing can ensure that students receive all of the essential material. The aim of this study is to compare the efficacy of e-learning and near-peer teaching during the pre-clinical medical curriculum. Thirty-nine second-year medical students were consented and randomised into two groups. Each group received teaching on electrocardiogram (ECG) interpretation from a predefined syllabus. Eighteen students completed an e-learning module and 21 students attended a near-peer tutorial. Students were asked to complete a multiple-choice exam, scored out of 50. Each student rated their confidence in ECG interpretation before and after their allocated teaching session. The near-peer group (84%) demonstrated a significantly higher performance than the e-learning group (74.5%) on the final assessment (p = 0.002). Prior to the teaching, the students' mean confidence scores were 3/10 in both the near-peer and e-learning groups (0, poor; 10, excellent). These increased to 6/10 in both cases following the teaching session. Both teaching styles were well received by students and improved their confidence in ECG interpretation. Near-peer teaching led to superior scores in our final assessment. Given the congested nature of the modern medical curriculum, direct comparison of the efficacy of these methods may aid course design. The aim of this study is to compare the efficacy of e-learning and near-peer teaching. © 2015 John Wiley & Sons Ltd.
Kenttä, Tuomas; Porthan, Kimmo; Tikkanen, Jani T; Väänänen, Heikki; Oikarinen, Lasse; Viitasalo, Matti; Karanko, Hannu; Laaksonen, Maarit; Huikuri, Heikki V
2015-07-01
Early repolarization (ER) is defined as an elevation of the QRS-ST junction in at least two inferior or lateral leads of the standard 12-lead electrocardiogram (ECG). Our purpose was to create an algorithm for the automated detection and classification of ER. A total of 6,047 electrocardiograms were manually graded for ER by two experienced readers. The automated detection of ER was based on quantification of the characteristic slurring or notching in ER-positive leads. The ER detection algorithm was tested and its results were compared with manual grading, which served as the reference. Readers graded 183 ECGs (3.0%) as ER positive, of which the algorithm detected 176 recordings, resulting in sensitivity of 96.2%. Of the 5,864 ER-negative recordings, the algorithm classified 5,281 as negative, resulting in 90.1% specificity. Positive and negative predictive values for the algorithm were 23.2% and 99.9%, respectively, and its accuracy was 90.2%. Inferior ER was correctly detected in 84.6% and lateral ER in 98.6% of the cases. As the automatic algorithm has high sensitivity, it could be used as a prescreening tool for ER; only the electrocardiograms graded positive by the algorithm would be reviewed manually. This would reduce the need for manual labor by 90%. © 2014 Wiley Periodicals, Inc.
Maillot, N; Guenancia, C; Yameogo, N V; Gudjoncik, A; Garnier, F; Lorgis, L; Chagué, F; Cottin, Y
2018-02-01
To interpret the electrocardiogram (ECG) of athletes, the recommendations of the ESC and the Seattle criteria define type 1 peculiarities, those induced by training, and type 2, those not induced by training, to rule out cardiomyopathy. The specificity of the screening was improved by Sheikh who defined "Refined Criteria," which includes a group of intermediate peculiarities. The aim of our study was to investigate the influence of static and dynamic components on the prevalence of different types of abnormalities. The ECGs of 1030 athletes performed during preparticipation screening were interpreted using these three classifications. Our work revealed 62/16%, 69/13%, and 71/7% of type 1 peculiarities and type 2 abnormalities for the ESC, Seattle, and Refined Criteria algorithms, respectively(P<.001). For type 2 abnormalities, three independent factors were found for the ESC and Seattle criteria: age, Afro-Caribbean origin, and the dynamic component with, for the latter, an OR[95% CI] of 2.35[1.28-4.33] (P=.006) and 1.90[1.03-3.51] (P=.041), respectively. In contrast, only the Afro-Caribbean origin was associated with type 2 abnormalities using the Refined Criteria: OR[95% CI] 2.67[1.60-4.46] (P<.0001). The Refined Criteria classified more athletes in the type 1 category and fewer in the type 2 category compared with the ESC and Seattle algorithms. Contrary to previous studies, a high dynamic component was not associated with type 2 abnormalities when the Refined Criteria were used; only the Afro-Caribbean origin remained associated. Further research is necessary to better understand adaptations with regard to duration and thus improve the modern criteria for ECG screening in athletes. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
[ECG for non-competitive sports in childhood: strengths and disputes].
Poggi, Elena; Giannattasio, Alessandro; Bolloli, Sara; Beccaria, Andrea; Mezzano, Paola; Rocca, Paola; Del Vecchio, Cecilia
2016-11-01
Sport is very important for health promotion and conservation. Active lifestyle and regular exercise reduce cardiovascular disease incidence. The Italian Ministry of Health issued the Law Decree no. 243 (10/18/2014) concerning "guidelines for certification about non-competitive sports" to promote safety in sports. This regulation defines the activities for which a certificate is required, the professional actors involved and the clinical exams to be performed according to the patient's health status. In particular, the Law Decree recommends to perform an electrocardiogram (ECG) "at least once in a lifetime", introducing much greater news into pediatric practice. We proposed a survey evaluating frequency of ECG implementation for non-competitive sports and cardiovascular diseases incidence was administered to 7 Ligurian pediatricians. The number of ECG/year for pediatrician increased from 10 ECG/year to 50 ECG/year with an indication of suitability to non-competitive sports. One case of QT prolongation and 2 cases of type 1 Brugada ECG pattern were diagnosed. In addition, 3 patients had an atrial septal defect and 3 children had a ventricular septal defect. Forty-three percent of the pediatricians considered useful performing the ECG. ECG in children has enhanced the positive effects on the community health. However, it remains to be defined in agreement with scientific societies the age at which to perform ECG, the sports for which ECG is required and the cost-benefit ratio for the National Health System and families.
Marcolino, Milena Soriano; Santos, Thales Matheus Mendonça; Stefanelli, Fernanda Cotrim; Oliveira, João Antonio de Queiroz; E Silva, Maíra Viana Rego Souza; Andrade, Diomildo Ferreira; Silva, Grace Kelly Matos E; Ribeiro, Antonio Luiz
2017-01-01
Electrocardiograms (ECGs) are an essential examination for identification and management of cardiovascular emergencies.The aim of this study was to report on the frequency and recognition of cardiovascular emergencies in primary care units. Observational retrospective study assessing consecutive patients whose digital ECGs were sent for analysis to the team of the Telehealth Network of Minas Gerais. Data from patients diagnosed with cardiological emergencies in the primary care setting of 750 municipalities in Minas Gerais, Brazil, between March and September 2015, were collected via telephone contact with the healthcare practitioner who performed the ECG. After collection, the data were subjected to statistical analysis. Over the study period, 304 patients with cardiovascular emergencies were diagnosed within primary care. Only 73.4% of these were recognized by the local physicians. Overall, the most frequent ECG abnormalities were acute ischemic patterns (44.7%) and the frequency of such patterns was higher among the ECGs assigned as emergency priority (P = 0.03). It was possible to obtain complete information on 231 patients (75.9%). Among these, the mean age was 65 ± 14.4 years, 57.1% were men and the most prevalent comorbidity was hypertension (68.4%). In total, 77.9% were referred to a unit caring for cases of higher complexity and 11.7% of the patients died. In this study, cardiovascular emergencies were misdiagnosed in primary care settings, acute myocardial ischemia was the most frequent emergency and the mortality rate was high.
Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts.
Aramendi, Elisabete; de Gauna, Sofia Ruiz; Irusta, Unai; Ruiz, Jesus; Arcocha, M Fe; Ormaetxe, Jose Miguel
2007-01-01
Providing cardiopulmonary resuscitation (CPR) to a patient in cardiac arrest introduces artefacts into the electrocardiogram (ECG), corrupting the diagnosis of the underlying heart rhythm. CPR must therefore be discontinued for reliable shock advice analysis by an automated external defibrillator (AED). Detection of ventricular fibrillation (VF) during CPR would enable CPR to continue during AED rhythm analysis, thereby increasing the likelihood of resuscitation success. This study presents a new adaptive filtering method to clean the ECG. The approach consists of a filter that adapts its characteristics to the spectral content of the signal exclusively using the surface ECG that commercial AEDs capture through standard patches. A set of 200 VF and 25 CPR artefact samples collected from real out-of-hospital interventions were used to test the method. The performance of a shock advice algorithm was evaluated before and after artefact removal. CPR artefacts were added to the ECG signals and four degrees of corruption were tested. Mean sensitivities of 97.83%, 98.27%, 98.32% and 98.02% were achieved, producing sensitivity increases of 28.44%, 49.75%, 59.10% and 64.25%, respectively, sufficient for ECG analysis during CPR. Although satisfactory and encouraging sensitivity values have been obtained, further clinical and experimental investigation is required in order to integrate this type of artefact suppressing algorithm in current AEDs.
Presetting ECG electrodes for earlier heart rate detection in the delivery room.
Gulati, Rashmi; Zayek, Michael; Eyal, Fabien
2018-07-01
To determine whether heart rate (HR) could be detected earlier than by pulse oximeter (POX), using a novel method of application of electrocardiogram (ECG) electrodes during neonatal resuscitation in the delivery room. ECG electrodes were set before delivery to be applied to the back of infants' thorax. Time to detect HR was recorded as soon as a numerical HR along with a recognizable and persistent QRS complex was observed on ECG monitor (HRECG) and a plethysmographic waveform was seen on POX monitor (HRPOX). Out of 334 infants, 49 were <31 weeks of gestational age. Overall, the median (interquartile range, IQR) time to detect HRECG was significantly shorter [29 (5, 60) seconds] than time by POX [60 (45,120) seconds], (p < 0.001). Similarly, in <31-week infants, the median (IQR) time to detect HRECG was 10 (2, 40) seconds compared to 60 (30,120) seconds by POX, (p < 0.001). Failure to have HR detected by 1 minute occurred in 30%, 54% and 20% of infants by ECG, POX and either of the devices, respectively. In the delivery room, electrodes applied by the study method are more effective than pulse oximetry in providing the neonatal team with timely HR information that is necessary for proper resuscitative actions. Published by Elsevier B.V.
Development of a wearable multi-frequency impedance cardiography device.
Weyer, Sören; Menden, Tobias; Leicht, Lennart; Leonhardt, Steffen; Wartzek, Tobias
2015-02-01
Cardiovascular diseases as well as pulmonary oedema can be early diagnosed using vital signs and thoracic bio-impedance. By recording the electrocardiogram (ECG) and the impedance cardiogram (ICG), vital parameters are captured continuously. The aim of this study is the continuous monitoring of ECG and multi-frequency ICG by a mobile system. A mobile measuring system, based on 'low-power' ECG, ICG and an included radio transmission is described. Due to the high component integration, a board size of only 6.5 cm×5 cm could be realized. The measured data can be transmitted via Bluetooth and visualized on a portable monitor. By using energy-efficient hardware, the system can operate for up to 18 hs with a 3 V battery, continuously sending data via Bluetooth. Longer operating times can be realized by decreased transfer rates. The relative error of the impedance measurement was less than 1%. The ECG and ICG measurements allow an approximate calculation of the heart stroke volume. The ECG and the measured impedance showed a high correlation to commercial devices (r=0.83, p<0.05). In addition to commercial devices, the developed system allows a multi-frequency measurement of the thoracic impedance between 5-150 kHz.
Pudło, Joanna; Wierdak, Mateusz; Macioł, Karolina; Gumul, Katarzyna; Lelakowski, Jacek
2012-01-01
The electrocardiogram (ECG) examination is one of the most frequent administered diagnostic tests. It is commonly ordered by General Practitioners, and it has became a routinely administered examination during admission to the hospital. During their studies, medical students has numerous opportunities to review and interpret the results of these tests. The aim of our research was to statistically compare and contrast the knowledge of the rules and practical skills in the interpretation of ECGs in 4th, 5th and 6th year medical students at Jagiellonian University. We wanted to better define in which year the students acquire the most of their clinical skills and determine if 6th year students have sufficient knowledge and skills to adequately perform in their future career. We additionally wanted to understand from which source students draw their knowledge of the ECG. The population of 249- 4th, 5th and 6th year medical students of Jagiellonian University were asked to reply to an anonymous questionnaire. The questionnaire was comprised of three parts. The fist part contains four simple ECGs (STEMI, RBBB, PVC, normogram--sinus rhythm). The second part contained six questions regarding their theoretical knowledge. The third part contained seven questions which evaluated the students' background and approach to the problem. Students filled the questionnaire without prior preparation to avoid the short-term "examination knowledge". The question that was most frequent answered correctly was question regarding the proper time (in milliseconds) of QRS complex (24.1%). Differences in the percentage of correct answers to questionnaire amongst 4th and 5th year students were statistically uncharacteristic. The percentage of correct answers of 6th year students increased by about 16% (p < 0.0001). The comparison of answers between 6th year students - who in prior semester completed a cardiology course (group A 6th year) and 6th year students who did not yet complete cardiology course (group B 6th year) showed significant improvement in group A in the percentage of correct answers for all questions about ECG. The percentage of correct answers in group A was an average 62% and in group B 45.5% (p < 0.00025). In case of 4th and 5th year students, the picture was uncharacteristic. Self study of ECG had a significant, positive influence in the percentage of correct answers amongst respondents, especially in the 6th year student population. Improvement was also seen in 4th and 5th students, but to a lesser degree. Among the 6th year students who benefited from self study, their percentage of correct answers was nearly two times then that of their fellow of 6th year students who did not self study (p < 0.0001). Only 3 of questioned students stated that they felt that their present knowledge of ECG is sufficient. 4th and 5th year students have comparable knowledge of ECG. 6th year students showed a significantly improved ability to interpret the ECG, especially those who had already completed cardiology course in present term. The increase in skills of interpretation of ECG is gained primarily by self study.
An effective and efficient compression algorithm for ECG signals with irregular periods.
Chou, Hsiao-Hsuan; Chen, Ying-Jui; Shiau, Yu-Chien; Kuo, Te-Son
2006-06-01
This paper presents an effective and efficient preprocessing algorithm for two-dimensional (2-D) electrocardiogram (ECG) compression to better compress irregular ECG signals by exploiting their inter- and intra-beat correlations. To better reveal the correlation structure, we first convert the ECG signal into a proper 2-D representation, or image. This involves a few steps including QRS detection and alignment, period sorting, and length equalization. The resulting 2-D ECG representation is then ready to be compressed by an appropriate image compression algorithm. We choose the state-of-the-art JPEG2000 for its high efficiency and flexibility. In this way, the proposed algorithm is shown to outperform some existing arts in the literature by simultaneously achieving high compression ratio (CR), low percent root mean squared difference (PRD), low maximum error (MaxErr), and low standard derivation of errors (StdErr). In particular, because the proposed period sorting method rearranges the detected heartbeats into a smoother image that is easier to compress, this algorithm is insensitive to irregular ECG periods. Thus either the irregular ECG signals or the QRS false-detection cases can be better compressed. This is a significant improvement over existing 2-D ECG compression methods. Moreover, this algorithm is not tied exclusively to JPEG2000. It can also be combined with other 2-D preprocessing methods or appropriate codecs to enhance the compression performance in irregular ECG cases.
Biometric and Emotion Identification: An ECG Compression Based Method.
Brás, Susana; Ferreira, Jacqueline H T; Soares, Sandra C; Pinho, Armando J
2018-01-01
We present an innovative and robust solution to both biometric and emotion identification using the electrocardiogram (ECG). The ECG represents the electrical signal that comes from the contraction of the heart muscles, indirectly representing the flow of blood inside the heart, it is known to convey a key that allows biometric identification. Moreover, due to its relationship with the nervous system, it also varies as a function of the emotional state. The use of information-theoretic data models, associated with data compression algorithms, allowed to effectively compare ECG records and infer the person identity, as well as emotional state at the time of data collection. The proposed method does not require ECG wave delineation or alignment, which reduces preprocessing error. The method is divided into three steps: (1) conversion of the real-valued ECG record into a symbolic time-series, using a quantization process; (2) conditional compression of the symbolic representation of the ECG, using the symbolic ECG records stored in the database as reference; (3) identification of the ECG record class, using a 1-NN (nearest neighbor) classifier. We obtained over 98% of accuracy in biometric identification, whereas in emotion recognition we attained over 90%. Therefore, the method adequately identify the person, and his/her emotion. Also, the proposed method is flexible and may be adapted to different problems, by the alteration of the templates for training the model.
Biometric and Emotion Identification: An ECG Compression Based Method
Brás, Susana; Ferreira, Jacqueline H. T.; Soares, Sandra C.; Pinho, Armando J.
2018-01-01
We present an innovative and robust solution to both biometric and emotion identification using the electrocardiogram (ECG). The ECG represents the electrical signal that comes from the contraction of the heart muscles, indirectly representing the flow of blood inside the heart, it is known to convey a key that allows biometric identification. Moreover, due to its relationship with the nervous system, it also varies as a function of the emotional state. The use of information-theoretic data models, associated with data compression algorithms, allowed to effectively compare ECG records and infer the person identity, as well as emotional state at the time of data collection. The proposed method does not require ECG wave delineation or alignment, which reduces preprocessing error. The method is divided into three steps: (1) conversion of the real-valued ECG record into a symbolic time-series, using a quantization process; (2) conditional compression of the symbolic representation of the ECG, using the symbolic ECG records stored in the database as reference; (3) identification of the ECG record class, using a 1-NN (nearest neighbor) classifier. We obtained over 98% of accuracy in biometric identification, whereas in emotion recognition we attained over 90%. Therefore, the method adequately identify the person, and his/her emotion. Also, the proposed method is flexible and may be adapted to different problems, by the alteration of the templates for training the model. PMID:29670564
[Electrocardiographic diagnosis: when QRS is wide.
Conti, Matilde; Bregani, Enrico Rino
2018-04-01
Differential diagnosis of one or more wide QRS complexes on an electrocardiogram under emergency conditions takes into account three main sets of clinical conditions: ventricular pre-excitation, aberrant conduction and ventricular beats and it is based on the morphological analysis of the ECG and patient's anamnestic data. Several criteria can facilitate the differential diagnosis and if properly used and integrated with clinic data they can achieve good diagnostic accuracy in most cases. In this review several criteria based on evidence and literature are presented, paying attention in recognizing some morphologic pathways that can be used in emergency room and allow a correct ECG assessment.
Study of ECG changes and its relation to mortality in cases of cerebrovascular accidents.
Purushothaman, Suja; Salmani, Deepalaxmi; Prarthana, Kaleramma Gopalakrishna; Bandelkar, Srinidhi Muddanna Gundappa; Varghese, Sarah
2014-07-01
Its being long recognized about the highly debilitating and destructive nature of cerebrovascular accidents (CVAs). Around the world CVAs has posed as a major factor in medical morbidity and mortality. It has thrown up challenges with regards to their medical management and also towards posttreatment rehabilitation. It is well-known that neurologic disorder contributes variously towards varied electrocardiogram (ECG) changes and stroke is no exception. To study the ECG changes and its relation to mortality in cases of CVA. A total of 100 patients with acute stroke were enrolled in the study. All the 100 patients underwent ECG recording within first 24 h of admission. The patients were divided into ischemic and hemorrhagic group depending on the nature of lesion. Out of 100 cases, 58 were ischemic and 42 were hemorrhagic. The ECG changes were noted in 78 patients. Among the ischemic group, the changes noted in the ECG were: T wave inversion (34.48%), ST segment depression (32.75%), QTc prolongation (29.31%), and presence of U waves (27.58%). In cases of hemorrhagic stroke, it was: T wave inversion (33.33%), arrhythmias (33.33%), U waves (30.95%), and ST segment depression (23.80%). Mortality was higher in patients with ST-T changes in ischemic group (66.66%) and in patients with positive U waves (60%) in hemorrhagic group. In acute stroke patients, changes in ECG were commonly seen. The changes varied from T-wave inversion to ST segment depression in ischemic stroke. In hemorrhagic stroke it consisted of T wave inversion and arrhythmias. Overall mortality was high in cases of hemorrhagic compared to ischemic group.
Study of ECG changes and its relation to mortality in cases of cerebrovascular accidents
Purushothaman, Suja; Salmani, Deepalaxmi; Prarthana, Kaleramma Gopalakrishna; Bandelkar, Srinidhi Muddanna Gundappa; Varghese, Sarah
2014-01-01
Background: Its being long recognized about the highly debilitating and destructive nature of cerebrovascular accidents (CVAs). Around the world CVAs has posed as a major factor in medical morbidity and mortality. It has thrown up challenges with regards to their medical management and also towards posttreatment rehabilitation. It is well-known that neurologic disorder contributes variously towards varied electrocardiogram (ECG) changes and stroke is no exception. Objective: To study the ECG changes and its relation to mortality in cases of CVA. Materials and Methods: A total of 100 patients with acute stroke were enrolled in the study. All the 100 patients underwent ECG recording within first 24 h of admission. The patients were divided into ischemic and hemorrhagic group depending on the nature of lesion. Results: Out of 100 cases, 58 were ischemic and 42 were hemorrhagic. The ECG changes were noted in 78 patients. Among the ischemic group, the changes noted in the ECG were: T wave inversion (34.48%), ST segment depression (32.75%), QTc prolongation (29.31%), and presence of U waves (27.58%). In cases of hemorrhagic stroke, it was: T wave inversion (33.33%), arrhythmias (33.33%), U waves (30.95%), and ST segment depression (23.80%). Mortality was higher in patients with ST-T changes in ischemic group (66.66%) and in patients with positive U waves (60%) in hemorrhagic group. Conclusion: In acute stroke patients, changes in ECG were commonly seen. The changes varied from T-wave inversion to ST segment depression in ischemic stroke. In hemorrhagic stroke it consisted of T wave inversion and arrhythmias. Overall mortality was high in cases of hemorrhagic compared to ischemic group. PMID:25097430
Schulze, Walther H. W.; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar
2015-01-01
In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2–11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold. PMID:26587538
Loewe, Axel; Schulze, Walther H W; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar
2015-01-01
In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2-11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.
Electrocardiogram reference intervals for clinically normal wild-born chimpanzees (Pan troglodytes).
Atencia, Rebeca; Revuelta, Luis; Somauroo, John D; Shave, Robert E
2015-08-01
To generate reference intervals for ECG variables in clinically normal chimpanzees (Pan troglodytes). 100 clinically normal (51 young [< 10 years old] and 49 adult [≥ 10 years old]) wild-born chimpanzees. Electrocardiograms collected between 2009 and 2013 at the Tchimpounga Chimpanzee Rehabilitation Centre were assessed to determine heart rate, PR interval, QRS duration, QT interval, QRS axis, P axis, and T axis. Electrocardiographic characteristics for left ventricular hypertrophy (LVH) and morphology of the ST segment, T wave, and QRS complex were identified. Reference intervals for young and old animals were calculated as mean ± 1.96•SD for normally distributed data and as 5th to 95th percentiles for data not normally distributed. Differences between age groups were assessed by use of unpaired Student t tests. RESULTS Reference intervals were generated for young and adult wild-born chimpanzees. Most animals had sinus rhythm with small or normal P wave morphology; 24 of 51 (47%) young chimpanzees and 30 of 49 (61%) adult chimpanzees had evidence of LVH as determined on the basis of criteria for humans. Cardiac disease has been implicated as the major cause of death in captive chimpanzees. Species-specific ECG reference intervals for chimpanzees may aid in the diagnosis and treatment of animals with, or at risk of developing, heart disease. Chimpanzees with ECG characteristics outside of these intervals should be considered for follow-up assessment and regular cardiac monitoring.
Missing RRI interpolation for HRV analysis using locally-weighted partial least squares regression.
Kamata, Keisuke; Fujiwara, Koichi; Yamakawa, Toshiki; Kano, Manabu
2016-08-01
The R-R interval (RRI) fluctuation in electrocardiogram (ECG) is called heart rate variability (HRV). Since HRV reflects autonomic nervous function, HRV-based health monitoring services, such as stress estimation, drowsy driving detection, and epileptic seizure prediction, have been proposed. In these HRV-based health monitoring services, precise R wave detection from ECG is required; however, R waves cannot always be detected due to ECG artifacts. Missing RRI data should be interpolated appropriately for HRV analysis. The present work proposes a missing RRI interpolation method by utilizing using just-in-time (JIT) modeling. The proposed method adopts locally weighted partial least squares (LW-PLS) for RRI interpolation, which is a well-known JIT modeling method used in the filed of process control. The usefulness of the proposed method was demonstrated through a case study of real RRI data collected from healthy persons. The proposed JIT-based interpolation method could improve the interpolation accuracy in comparison with a static interpolation method.
Artifact removal from EEG signals using adaptive filters in cascade
NASA Astrophysics Data System (ADS)
Garcés Correa, A.; Laciar, E.; Patiño, H. D.; Valentinuzzi, M. E.
2007-11-01
Artifacts in EEG (electroencephalogram) records are caused by various factors, like line interference, EOG (electro-oculogram) and ECG (electrocardiogram). These noise sources increase the difficulty in analyzing the EEG and to obtaining clinical information. For this reason, it is necessary to design specific filters to decrease such artifacts in EEG records. In this paper, a cascade of three adaptive filters based on a least mean squares (LMS) algorithm is proposed. The first one eliminates line interference, the second adaptive filter removes the ECG artifacts and the last one cancels EOG spikes. Each stage uses a finite impulse response (FIR) filter, which adjusts its coefficients to produce an output similar to the artifacts present in the EEG. The proposed cascade adaptive filter was tested in five real EEG records acquired in polysomnographic studies. In all cases, line-frequency, ECG and EOG artifacts were attenuated. It is concluded that the proposed filter reduces the common artifacts present in EEG signals without removing significant information embedded in these records.
NASA Astrophysics Data System (ADS)
Tian, Shudong; Han, Jun; Yang, Jianwei; Zeng, Xiaoyang
2017-10-01
Electrocardiogram (ECG) can be used as a valid way for diagnosing heart disease. To fulfill ECG processing in wearable devices by reducing computation complexity and hardware cost, two kinds of adaptive filters are designed to perform QRS complex detection and motion artifacts removal, respectively. The proposed design achieves a sensitivity of 99.49% and a positive predictivity of 99.72%, tested under the MIT-BIH ECG database. The proposed design is synthesized under the SMIC 65-nm CMOS technology and verified by post-synthesis simulation. Experimental results show that the power consumption and area cost of this design are of 160 μW and 1.09 × 10 5 μm2, respectively. Project supported by the National Natural Science Foundation of China (Nos. 61574040, 61234002, 61525401).
Mason, Jay W; Hancock, E William; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Josephson, Mark; Kligfield, Paul; Kors, Jan A; Macfarlane, Peter; Pahlm, Olle; Mirvis, David M; Okin, Peter; Rautaharju, Pentti; Surawicz, Borys; van Herpen, Gerard; Wagner, Galen S; Wellens, Hein
2007-03-13
This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.
Mason, Jay W; Hancock, E William; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Josephson, Mark; Kligfield, Paul; Kors, Jan A; Macfarlane, Peter; Pahlm, Olle; Mirvis, David M; Okin, Peter; Rautaharju, Pentti; Surawicz, Borys; van Herpen, Gerard; Wagner, Galen S; Wellens, Hein
2007-03-13
This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.
A cancelable biometric scheme based on multi-lead ECGs.
Peng-Tzu Chen; Shun-Chi Wu; Jui-Hsuan Hsieh
2017-07-01
Biometric technologies offer great advantages over other recognition methods, but there are concerns that they may compromise the privacy of individuals. In this paper, an electrocardiogram (ECG)-based cancelable biometric scheme is proposed to relieve such concerns. In this scheme, distinct biometric templates for a given beat bundle are constructed via "subspace collapsing." To determine the identity of any unknown beat bundle, the multiple signal classification (MUSIC) algorithm, incorporating a "suppression and poll" strategy, is adopted. Unlike the existing cancelable biometric schemes, knowledge of the distortion transform is not required for recognition. Experiments with real ECGs from 285 subjects are presented to illustrate the efficacy of the proposed scheme. The best recognition rate of 97.58 % was achieved under the test condition N train = 10 and N test = 10.
Competency in ECG Interpretation Among Medical Students
Kopeć, Grzegorz; Magoń, Wojciech; Hołda, Mateusz; Podolec, Piotr
2015-01-01
Background Electrocardiogram (ECG) is commonly used in diagnosis of heart diseases, including many life-threatening disorders. We aimed to assess skills in ECG interpretation among Polish medical students and to analyze the determinants of these skills. Material/Methods Undergraduates from all Polish medical schools were asked to complete a web-based survey containing 18 ECG strips. Questions concerned primary ECG parameters (rate, rhythm, and axis), emergencies, and common ECG abnormalities. Analysis was restricted to students in their clinical years (4th–6th), and students in their preclinical years (1st–3rd) were used as controls. Results We enrolled 536 medical students (females: n=299; 55.8%), aged 19 to 31 (23±1.6) years from all Polish medical schools. Most (72%) were in their clinical years. The overall rate of good response was better in students in years 4th–5th than those in years 1st–3rd (66% vs. 56%; p<0.0001). Competency in ECG interpretation was higher in students who reported ECG self-learning (69% vs. 62%; p<0.0001) but no difference was found between students who attended or did not attend regular ECG classes (66% vs. 66%; p=0.99). On multivariable analysis (p<0.0001), being in clinical years (OR: 2.45 [1.35–4.46] and self-learning (OR: 2.44 [1.46–4.08]) determined competency in ECG interpretation. Conclusions Polish medical students in their clinical years have a good level of competency in interpreting the primary ECG parameters, but their ability to recognize ECG signs of emergencies and common heart abnormalities is low. ECG interpretation skills are determined by self-education but not by attendance at regular ECG classes. Our results indicate qualitative and quantitative deficiencies in teaching ECG interpretation at medical schools. PMID:26541993
2013-01-01
Background Extracorporeal cardiopulmonary resuscitation (ECPR) refers to the application of extracorporeal blood circulation with oxygenation as a resuscitation tool. The objective of this study is to observe the frequency component changes in the electrocardiogram (ECG) by ECPR during prolonged ventricular fibrillation (VF). Methods Six swine were prepared as a VF model. Extracorporeal blood circulation with a pulsatile blood pump and oxygenator was set up for the model. ECG signals were measured for 13 min during VF and analyzed using frequency analysis methods. The median frequency (MF), dominant frequency (DF), and amplitude spectrum area (AMSA) were calculated from a spectrogram obtained using short-time Fourier transform (STFT). Results MF decreased from 11 Hz at the start to 9 Hz at 2 min after VF and then increased to 11 Hz at 4.5 min after VF. DF started at 7 Hz and increased to 11 Hz within the first min and decreased to 9 Hz at 2 min, then increased to 12 Hz at 4.5 min after VF. Both frequency components decreased gradually from 4.5 min until 10 min after VF. After the oxygenated blood perfusion was initiated, both MF and DF increased remarkably and exceeded 12 and 14 Hz, respectively. Similarly, AMSA decreased gradually for the first 10 min, but increased remarkably and varied beyond 13 mV∙Hz after the oxygenated blood supply started. Remarkable frequency increases in ECG due to the oxygenated blood perfusion during ECPR were observed in the swine VF model. Conclusions The ECG frequency analysis during ECPR can give the resuscitation provider important information about the cardiac perfusion status and the appropriateness of the ECPR setup as well as the prediction of defibrillation success. PMID:24274395
Jørgensen, Peter G; Jensen, Jan S; Appleyard, Merete; Jensen, Gorm B; Mogelvang, Rasmus
2015-12-15
Though the electrocardiogram(ECG) and plasma pro-brain-natriuretic-peptide (pro-BNP) are widely used markers of subclinical cardiac injury and can be used to predict future cardiovascular disease(CVD), they could merely be markers of the same underlying pathology. We aimed to determine if ECG changes and pro-BNP are independent predictors of CVD and if the combination improves risk prediction in persons without known heart disease. Pro-BNP and ECG were obtained on 5454 persons without known heart disease from the 4th round of the Copenhagen City Heart Study, a prospective cohort study. Median follow-up was 10.4 years. High pro-BNP was defined as above 90th percentile of age and sex adjusted levels. The end-points were all-cause mortality and the combination of admission with ischemic heart disease, heart failure or CVD death. ECG changes were present in 907 persons and were associated with high levels of pro-BNP. In a fully adjusted model both high pro-BNP and ECG changes remained significant predictors: all-cause mortality(high pro-BNP, no ECG changes: HR: 1.43(1.12-1.82);P=0.005, low pro-BNP, ECG changes: HR: 1.22(1.05-1.42);P=0.009, and both high pro-BNP and ECG changes: HR: 1.99(1.54-2.59);P<0.001), CVD event(high pro-BNP, no ECG changes: HR: 1.94(1.45-2.58);P<0.001, low pro-BNP, ECG changes: HR: 1.55(1.29-1.87);P<0.001, and both high pro-BNP and ECG changes: HR: 3.86(2.94-5.08);P<0.001). Adding the combination of pro-BNP and ECG changes to a fully adjusted model correctly reclassified 33.9%(26.5-41.3);P<0.001 on the continuous net reclassification scale for all-cause mortality and 49.7%(41.1-58.4);P<0.001 for CVD event. Combining ECG changes and pro-BNP improves risk prediction in persons without known heart disease. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Pourmand, Ali; Tanski, Mary; Davis, Steven; Shokoohi, Hamid; Lucas, Raymond; Zaver, Fareen
2015-01-01
Asynchronous online training has become an increasingly popular educational format in the new era of technology-based professional development. We sought to evaluate the impact of an online asynchronous training module on the ability of medical students and emergency medicine (EM) residents to detect electrocardiogram (ECG) abnormalities of an acute myocardial infarction (AMI). We developed an online ECG training and testing module on AMI, with emphasis on recognizing ST elevation myocardial infarction (MI) and early activation of cardiac catheterization resources. Study participants included senior medical students and EM residents at all post-graduate levels rotating in our emergency department (ED). Participants were given a baseline set of ECGs for interpretation. This was followed by a brief interactive online training module on normal ECGs as well as abnormal ECGs representing an acute MI. Participants then underwent a post-test with a set of ECGs in which they had to interpret and decide appropriate intervention including catheterization lab activation. 148 students and 35 EM residents participated in this training in the 2012-2013 academic year. Students and EM residents showed significant improvements in recognizing ECG abnormalities after taking the asynchronous online training module. The mean score on the testing module for students improved from 5.9 (95% CI [5.7-6.1]) to 7.3 (95% CI [7.1-7.5]), with a mean difference of 1.4 (95% CI [1.12-1.68]) (p<0.0001). The mean score for residents improved significantly from 6.5 (95% CI [6.2-6.9]) to 7.8 (95% CI [7.4-8.2]) (p<0.0001). An online interactive module of training improved the ability of medical students and EM residents to correctly recognize the ECG evidence of an acute MI.
Banerjee, Maalika M; Ramesh Iyer, V; Nandi, Deipanjan; Vetter, Victoria L; Banerjee, Anirban
2016-04-01
In the outpatient setting, children who present with syncope routinely undergo electrocardiograms (ECG). Because of concerns for hypertrophic cardiomyopathy, children with syncope meeting ECG criteria for left ventricular hypertrophy (LVH) will frequently undergo an echocardiogram. Our objectives were to determine whether Davignon criteria for ECG waves overestimate LVH in children presenting with syncope, and to study the usefulness of echocardiography in these children. We hypothesize that the Davignon criteria presently used for interpretation of ECGs overestimate LVH, resulting in unnecessary echocardiography in this clinical setting. The clinical database of The Children's Hospital of Philadelphia was evaluated from 2002 to 2012 to identify children between 9 and 16 years of age, who presented with non-exercise-induced, isolated syncope. From this group of patients, only those with clear-cut evidence of LVH (by Davignon criteria), who also underwent an echocardiogram, were selected. A total of 136 children with syncope were identified as having LVH by Davignon ECG criteria. None of these patients manifested any evidence of hypertrophic cardiomyopathy, with normal ventricular septum (average Z-score -0.68 ± 0.84), LV posterior wall (average Z-score -0.66 ± 1.18) and LV mass (average Z-score 0.52 ± 1.29). No significant correlation was found between summed RV6 plus SV1 and LV mass. Correlations between additional ECG parameters and measures of LVH by echocardiography were similarly poor. In children presenting with syncope and LVH by ECG, there was no evidence of true LVH by echocardiography. We propose that the Davignon ECG criteria for interpreting LVH in children overestimate the degree of hypertrophy in these children and the yield of echocardiography is extremely low.
Lowres, Nicole; Mulcahy, Georgina; Gallagher, Robyn; Ben Freedman, Saul; Marshman, David; Kirkness, Ann; Orchard, Jessica; Neubeck, Lis
2016-07-01
Postoperative atrial fibrillation (POAF) occurs in 25-40% of patients following cardiac surgery, and is associated with a significant increased risk of stroke and mortality. Routine surveillance is not performed post-discharge; however, recurrence of POAF can occur in up to 30% of patients discharged in sinus rhythm. This study aimed to determine the feasibility of patients self-monitoring with an iPhone handheld electrocardiogram (iECG) to identify recurrence of POAF in the post-discharge period following cardiac surgery. Patients with POAF following cardiac surgery were eligible for participation if they had no prior history of atrial fibrillation (AF) and were discharged home in stable sinus rhythm. Participants were provided with an iECG and asked to record a 30-s iECG, four times per day for 4 weeks post-discharge. iECGs were automatically transmitted to a secure server, and reviewed for the presence of AF by the research team and a validated algorithm. All participants also received brief education on AF. Forty-two participants completed the intervention (mean age 69 ± 9 years, 80% male). Self-monitoring for POAF recurrence using an iECG was feasible and acceptable, and participants felt empowered. Self-monitoring identified 24% (95% confidence interval, 12-39%) with an AF recurrence within 17 days of hospital discharge. These participants were significantly younger than those without AF recurrence (64 ± 7 vs 70 ± 10 years; P = 0.025), and had a significantly lower CHA2DS2-VASc score (2.3 ± 1.2 vs 3.7 ± 2.3; P = 0.007). However, 80% were at high enough stroke risk to warrant consideration of anticoagulation, i.e. CHA2DS2-VASc score ≥2. Only 30% of recurrences were associated with palpitations. Participation also improved AF knowledge from 6.4 ± 1.8 to 7.3 ± 1.8 (P = 0.02), of a total score of 10. Providing patients with an iECG is a non-invasive, inexpensive, convenient and feasible way to monitor for AF recurrence in post-cardiac surgery patients. It also provides a mechanism to provide knowledge about the condition and also potentially reduce anxiety. The success of patients using this technology also has implications for extending the use of iECG self-monitoring to other patient groups such as those undergoing antiarrhythmic interventions for AF. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Çiçek, Yüksel; Çetin, Mustafa; Duman, Hakan; Şatiroğlu, Ömer; Çelik, Şükrü
2017-01-01
Background Prolonged QRS duration is associated with decreased left ventricular (LV) systolic function. However, the relation between LV restrictive filling pattern (RFP) and QRS duration has not been investigated yet. The purpose of our study was to assess this relationship. Methods We analyzed standard 12-lead surface electrocardiogram (ECG) of 155 consecutive patients. Mitral inflow and septal tissue velocities were obtained using the apical 4-chamber view with pulsed Doppler echocardiography. Patients were divided into 2 groups according to measured deceleration time (DT): restrictive (with DT ≤130 ms) or non-restrictive (with DT >130 ms). Results QRS duration was significantly longer in the restrictive group than in the non-restrictive group (0.101 vs. 0.090 s, p < 0.0001). QRS duration of >0.10 s was highly specific (82.6%), but modestly sensitive (64.7%), for the prediction of LV RFP. Multivariate analyses demonstrated that E/A ratio, peak E, peak A, septal e’, and a’ velocities were significantly associated with RFP. Conclusions Prolonged QRS duration (>0.10 s) obtained from a standard resting 12-lead ECG is associated with LV RFP. However, the relationship of QRS duration with RFP was not independent of echocardiographic parameters. PMID:28932490
Mahdavi, Naser
2014-01-01
In light of the popularity and also the various nutritional and medicinal properties of Berberis integerrima, this study was conducted to assess the influence of its aqueous extract on hemodynamic and electrocardiogram (ECG) indices of rat. Animals were divided to control (CTL), B50, B100, and B200 groups that orally received tap water, aqueous extracts of B. integerrima fruit 50, 100, and 200 mg/kg/day, respectively, for two weeks and on day 15, data were recorded. Different doses of barberry fruit extract had no significant effect on blood pressure, heart rate, RR interval, P duration, and Q wave amplitude of electrocardiogram. Extract administration was associated with an incremental trend in PR interval that was not statistically significant. Higher doses (100 and 200 mg/kg) of extract significantly increased the QRS interval (P < 0.01 versus CTL and B50 groups) but decreased the QTc interval (P < 0.01 versus CTL group and P < 0.001 versus B50 group), the JT interval, and TpTe interval (P < 0.001 versus CTL and B50 groups). The results suggest that high doses of barberry extract definitely prolong the depolarization phase and shorten the repolarization phase of ventricular muscle and hence induce alteration in heart electrical conductivity. PMID:27351000
Panoramic ECG display versus conventional ECG: ischaemia detection by critical care nurses.
Wilson, Nick; Hassani, Aimen; Gibson, Vanessa; Lightfoot, Timothy; Zizzo, Claudio
2012-01-01
To compare accuracy and certainty of diagnosis of cardiac ischaemia using the Panoramic ECG display tool plus conventional 12-lead electrocardiogram (ECG) versus 12-lead ECG alone by UK critical care nurses who were members of the British Association of Critical Care Nurses (BACCN). Critically ill patients are prone to myocardial ischaemia. Symptoms may be masked by sedation or analgesia, and ECG changes may be the only sign. Critical care nurses have an essential role in detecting ECG changes promptly. Despite this, critical care nurses may lack expertise in interpreting ECGs and myocardial ischaemia often goes undetected by critical care staff. British Association of Critical Care Nurses (BACCN) members were invited to complete an online survey to evaluate the analysis of two sets of eight ECGs displayed alone and with the new display device. Data from 82 participants showed diagnostic accuracy improved from 67·1% reading ECG traces alone, to 96·0% reading ECG plus Panoramic ECG display tool (P < 0·01, significance level α = 0·05). Participants' diagnostic certainty score rose from 41·7% reading ECG alone to 66·8% reading ECG plus Panoramic ECG display tool (P < 0·01, α = 0·05). The Panoramic ECG display tool improves both accuracy and certainty of detecting ST segment changes among critical care nurses, when compared to conventional 12-lead ECG alone. This benefit was greatest with early ischaemic changes. Critical care nurses who are least confident in reading conventional ECGs benefit the most from the new display. Critical care nurses have an essential role in the monitoring of critically ill patients. However, nurses do not always have the expertise to detect subtle ischaemic ECG changes promptly. Introduction of the Panoramic ECG display tool into clinical practice could lead to patients receiving treatment for myocardial ischaemia sooner with the potential for reduction in morbidity and mortality. © 2012 The Authors. Nursing in Critical Care © 2012 British Association of Critical Care Nurses.
Improving Remote Health Monitoring: A Low-Complexity ECG Compression Approach
Al-Ali, Abdulla; Mohamed, Amr; Ward, Rabab
2018-01-01
Recent advances in mobile technology have created a shift towards using battery-driven devices in remote monitoring settings and smart homes. Clinicians are carrying out diagnostic and screening procedures based on the electrocardiogram (ECG) signals collected remotely for outpatients who need continuous monitoring. High-speed transmission and analysis of large recorded ECG signals are essential, especially with the increased use of battery-powered devices. Exploring low-power alternative compression methodologies that have high efficiency and that enable ECG signal collection, transmission, and analysis in a smart home or remote location is required. Compression algorithms based on adaptive linear predictors and decimation by a factor B/K are evaluated based on compression ratio (CR), percentage root-mean-square difference (PRD), and heartbeat detection accuracy of the reconstructed ECG signal. With two databases (153 subjects), the new algorithm demonstrates the highest compression performance (CR=6 and PRD=1.88) and overall detection accuracy (99.90% sensitivity, 99.56% positive predictivity) over both databases. The proposed algorithm presents an advantage for the real-time transmission of ECG signals using a faster and more efficient method, which meets the growing demand for more efficient remote health monitoring. PMID:29337892
Improving Remote Health Monitoring: A Low-Complexity ECG Compression Approach.
Elgendi, Mohamed; Al-Ali, Abdulla; Mohamed, Amr; Ward, Rabab
2018-01-16
Recent advances in mobile technology have created a shift towards using battery-driven devices in remote monitoring settings and smart homes. Clinicians are carrying out diagnostic and screening procedures based on the electrocardiogram (ECG) signals collected remotely for outpatients who need continuous monitoring. High-speed transmission and analysis of large recorded ECG signals are essential, especially with the increased use of battery-powered devices. Exploring low-power alternative compression methodologies that have high efficiency and that enable ECG signal collection, transmission, and analysis in a smart home or remote location is required. Compression algorithms based on adaptive linear predictors and decimation by a factor B / K are evaluated based on compression ratio (CR), percentage root-mean-square difference (PRD), and heartbeat detection accuracy of the reconstructed ECG signal. With two databases (153 subjects), the new algorithm demonstrates the highest compression performance ( CR = 6 and PRD = 1.88 ) and overall detection accuracy (99.90% sensitivity, 99.56% positive predictivity) over both databases. The proposed algorithm presents an advantage for the real-time transmission of ECG signals using a faster and more efficient method, which meets the growing demand for more efficient remote health monitoring.
Mild-to-moderate exercise is often used to stress the cardiovascular (CV) system of patients while monitoring them for electrocardiogram (ECG) abnormalities that may indicate underlying CV disease. We previously used dobutamine, which increases heart rate (HR) and contractility, ...
Shavadia, Jay S; French, William; Hellkamp, Anne S; Thomas, Laine; Bates, Eric R; Manoukian, Steven V; Kontos, Michael C; Suter, Robert; Henry, Timothy D; Dauerman, Harold L; Roe, Matthew T
2018-03-01
Assessing hospital-related network-level primary percutaneous coronary intervention (PCI) performance for ST-segment elevation myocardial infarction (STEMI) is challenging due to differential time-to-treatment metrics based on location of diagnostic electrocardiogram (ECG) for STEMI. STEMI patients undergoing primary PCI at 588 PCI-capable hospitals in AHA Mission: Lifeline (2008-2013) were categorized by initial STEMI identification location: PCI-capable hospitals (Group 1); pre-hospital setting (Group 2); and non-PCI-capable hospitals (Group 3). Patient-specific time-to-treatment categories were converted to minutes ahead of or behind their group-specific mean; average time-to-treatment difference for all patients at a given hospital was termed comprehensive ECG-to-device time. Hospitals were then stratified into tertiles based on their comprehensive ECG-to-device times with negative values below the mean representing shorter (faster) time intervals. Of 117,857 patients, the proportion in Groups 1, 2, and 3 were 42%, 33%, and 25%, respectively. Lower rates of heart failure and cardiac arrest at presentation are noted within patients presenting to high-performing hospitals. Median comprehensive ECG-to-device time was shortest at -9 minutes (25th, 75th percentiles: -13, -6) for the high-performing hospital tertile, 1 minute (-1, 3) for middle-performing, and 11 minutes (7, 16) for low-performing. Unadjusted rates of in-hospital mortality were 2.3%, 2.6%, and 2.7%, respectively, but the adjusted risk of in-hospital mortality was similar across tertiles. Comprehensive ECG-to-device time provides an integrated hospital-related network-level assessment of reperfusion timing metrics for primary PCI, regardless of the location for STEMI identification; further validation will delineate how this metric can be used to facilitate STEMI care improvements. Copyright © 2017 Elsevier Inc. All rights reserved.
Compressed sensing of ECG signal for wireless system with new fast iterative method.
Tawfic, Israa; Kayhan, Sema
2015-12-01
Recent experiments in wireless body area network (WBAN) show that compressive sensing (CS) is a promising tool to compress the Electrocardiogram signal ECG signal. The performance of CS is based on algorithms use to reconstruct exactly or approximately the original signal. In this paper, we present two methods work with absence and presence of noise, these methods are Least Support Orthogonal Matching Pursuit (LS-OMP) and Least Support Denoising-Orthogonal Matching Pursuit (LSD-OMP). The algorithms achieve correct support recovery without requiring sparsity knowledge. We derive an improved restricted isometry property (RIP) based conditions over the best known results. The basic procedures are done by observational and analytical of a different Electrocardiogram signal downloaded them from PhysioBankATM. Experimental results show that significant performance in term of reconstruction quality and compression rate can be obtained by these two new proposed algorithms, and help the specialist gathering the necessary information from the patient in less time if we use Magnetic Resonance Imaging (MRI) application, or reconstructed the patient data after sending it through the network. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Chowdhury, Shubhajit Roy
2012-04-01
The paper reports of a Field Programmable Gate Array (FPGA) based embedded system for detection of QRS complex in a noisy electrocardiogram (ECG) signal and thereafter differential diagnosis of tachycardia and tachyarrhythmia. The QRS complex has been detected after application of entropy measure of fuzziness to build a detection function of ECG signal, which has been previously filtered to remove power line interference and base line wander. Using the detected QRS complexes, differential diagnosis of tachycardia and tachyarrhythmia has been performed. The entire algorithm has been realized in hardware on an FPGA. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity (Se) of 99.74% and accuracy of 99.5% is achieved when tested using single channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in literature. Using the system, 200 patients have been diagnosed with an accuracy of 98.5%.
ECG-cryptography and authentication in body area networks.
Zhang, Zhaoyang; Wang, Honggang; Vasilakos, Athanasios V; Fang, Hua
2012-11-01
Wireless body area networks (BANs) have drawn much attention from research community and industry in recent years. Multimedia healthcare services provided by BANs can be available to anyone, anywhere, and anytime seamlessly. A critical issue in BANs is how to preserve the integrity and privacy of a person's medical data over wireless environments in a resource efficient manner. This paper presents a novel key agreement scheme that allows neighboring nodes in BANs to share a common key generated by electrocardiogram (ECG) signals. The improved Jules Sudan (IJS) algorithm is proposed to set up the key agreement for the message authentication. The proposed ECG-IJS key agreement can secure data communications over BANs in a plug-n-play manner without any key distribution overheads. Both the simulation and experimental results are presented, which demonstrate that the proposed ECG-IJS scheme can achieve better security performance in terms of serval performance metrics such as false acceptance rate (FAR) and false rejection rate (FRR) than other existing approaches. In addition, the power consumption analysis also shows that the proposed ECG-IJS scheme can achieve energy efficiency for BANs.
Peace, Aaron; Ramsewak, Adesh; Cairns, Andrew; Finlay, Dewar; Guldenring, Daniel; Clifford, Gari; Bond, Raymond
2015-01-01
The 12-lead electrocardiogram (ECG) is a crucial diagnostic tool. However, the ideal method to assess competency in ECG interpretation remains unclear. We sought to evaluate whether keypad response technology provides a rapid, interactive way to assess ECG knowledge. 75 participants were enrolled [32 (43%) Primary Care Physicians, 24 (32%) Hospital Medical Staff and 19 (25%) Nurse Practitioners]. Nineteen ECGs with 4 possible answers were interpreted. Out of 1425 possible decisions 1054 (73.9%) responses were made. Only 570/1425 (40%) of the responses were correct. Diagnostic accuracy varied (0% to 78%, mean 42%±21%) across the entire cohort. Participation was high, (median 83%, IQR 50%-100%). Hospital Medical Staff had significantly higher diagnostic accuracy than nurse practitioners (50±20% vs. 38±19%, p=0.04) and Primary Care Physicians (50±20% vs. 40±21%, p=0.07) although not significant. Interactive voting systems can be rapidly and successfully used to assess ECG interpretation. Further education is necessary to improve diagnostic accuracy. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan
2018-01-01
A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized. PMID:29414849
Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan
2018-02-07
A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.
Oresko, Joseph J; Duschl, Heather; Cheng, Allen C
2010-05-01
Cardiovascular disease (CVD) is the single leading cause of global mortality and is projected to remain so. Cardiac arrhythmia is a very common type of CVD and may indicate an increased risk of stroke or sudden cardiac death. The ECG is the most widely adopted clinical tool to diagnose and assess the risk of arrhythmia. ECGs measure and display the electrical activity of the heart from the body surface. During patients' hospital visits, however, arrhythmias may not be detected on standard resting ECG machines, since the condition may not be present at that moment in time. While Holter-based portable monitoring solutions offer 24-48 h ECG recording, they lack the capability of providing any real-time feedback for the thousands of heart beats they record, which must be tediously analyzed offline. In this paper, we seek to unite the portability of Holter monitors and the real-time processing capability of state-of-the-art resting ECG machines to provide an assistive diagnosis solution using smartphones. Specifically, we developed two smartphone-based wearable CVD-detection platforms capable of performing real-time ECG acquisition and display, feature extraction, and beat classification. Furthermore, the same statistical summaries available on resting ECG machines are provided.
Mincholé, Ana; Martínez, Juan Pablo; Laguna, Pablo; Rodriguez, Blanca
2018-01-01
Widely developed for clinical screening, electrocardiogram (ECG) recordings capture the cardiac electrical activity from the body surface. ECG analysis can therefore be a crucial first step to help diagnose, understand and predict cardiovascular disorders responsible for 30% of deaths worldwide. Computational techniques, and more specifically machine learning techniques and computational modelling are powerful tools for classification, clustering and simulation, and they have recently been applied to address the analysis of medical data, especially ECG data. This review describes the computational methods in use for ECG analysis, with a focus on machine learning and 3D computer simulations, as well as their accuracy, clinical implications and contributions to medical advances. The first section focuses on heartbeat classification and the techniques developed to extract and classify abnormal from regular beats. The second section focuses on patient diagnosis from whole recordings, applied to different diseases. The third section presents real-time diagnosis and applications to wearable devices. The fourth section highlights the recent field of personalized ECG computer simulations and their interpretation. Finally, the discussion section outlines the challenges of ECG analysis and provides a critical assessment of the methods presented. The computational methods reported in this review are a strong asset for medical discoveries and their translation to the clinical world may lead to promising advances. PMID:29321268
Variability in surface ECG morphology: signal or noise?
NASA Technical Reports Server (NTRS)
Smith, J. M.; Rosenbaum, D. S.; Cohen, R. J.
1988-01-01
Using data collected from canine models of acute myocardial ischemia, we investigated two issues of major relevance to electrocardiographic signal averaging: ECG epoch alignment, and the spectral characteristics of the beat-to-beat variability in ECG morphology. With initial digitization rates of 1 kHz, an iterative a posteriori matched filtering alignment scheme, and linear interpolation, we demonstrated that there is sufficient information in the body surface ECG to merit alignment to a precision of 0.1 msecs. Applying this technique to align QRS complexes and atrial pacing artifacts independently, we demonstrated that the conduction delay from atrial stimulus to ventricular activation may be so variable as to preclude using atrial pacing as an alignment mechanism, and that this variability in conduction time be modulated at the frequency of respiration and at a much lower frequency (0.02-0.03Hz). Using a multidimensional spectral technique, we investigated the beat-to-beat variability in ECG morphology, demonstrating that the frequency spectrum of ECG morphological variation reveals a readily discernable modulation at the frequency of respiration. In addition, this technique detects a subtle beat-to-beat alternation in surface ECG morphology which accompanies transient coronary artery occlusion. We conclude that physiologically important information may be stored in the variability in the surface electrocardiogram, and that this information is lost by conventional averaging techniques.
A robust approach for ECG-based analysis of cardiopulmonary coupling.
Zheng, Jiewen; Wang, Weidong; Zhang, Zhengbo; Wu, Dalei; Wu, Hao; Peng, Chung-Kang
2016-07-01
Deriving respiratory signal from a surface electrocardiogram (ECG) measurement has advantage of simultaneously monitoring of cardiac and respiratory activities. ECG-based cardiopulmonary coupling (CPC) analysis estimated by heart period variability and ECG-derived respiration (EDR) shows promising applications in medical field. The aim of this paper is to provide a quantitative analysis of the ECG-based CPC, and further improve its performance. Two conventional strategies were tested to obtain EDR signal: R-S wave amplitude and area of the QRS complex. An adaptive filter was utilized to extract the common component of inter-beat interval (RRI) and EDR, generating enhanced versions of EDR signal. CPC is assessed through probing the nonlinear phase interactions between RRI series and respiratory signal. Respiratory oscillations presented in both RRI series and respiratory signals were extracted by ensemble empirical mode decomposition for coupling analysis via phase synchronization index. The results demonstrated that CPC estimated from conventional EDR series exhibits constant and proportional biases, while that estimated from enhanced EDR series is more reliable. Adaptive filtering can improve the accuracy of the ECG-based CPC estimation significantly and achieve robust CPC analysis. The improved ECG-based CPC estimation may provide additional prognostic information for both sleep medicine and autonomic function analysis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Wolff-Parkinson-White Syndrome Mimics a Conduction Disease
Marrakchi, S.; Kammoun, I.; Kachboura, S.
2014-01-01
Background. It is important to recognise Wolff-Parkinson-White (WPW) syndrome in electrocardiograms (ECG), as it may mimic ischaemic heart disease, ventricular hypertrophy, and bundle branch block. Recognising WPW syndrome allows for risk stratification, the identification of associated conditions, and the institution of appropriate management. Objective. The present case showed that electrophysiological study is indicated in patients with abnormal ECG and syncope. Case Report. A 40-year-old man with Wolff-Parkinson-White syndrome was presented to emergency with syncope. A baseline ECG was a complete right branch block and posterior left hemiblock. He was admitted to the cardiac care unit for pacemaker implantation. The atypical figure of complete right branch block and posterior left hemiblock was thought to be a “false positive” of conduction abnormality. But the long anterograde refractory period of the both accessory pathway and atrioventricular conduction may cause difficulty in diagnosing Wolff-Parkinson-White syndrome, Conclusion. A Wolff-Parkinson-White Syndrome may mimic a conduction disease. No reliable algorithm exists for making an ECG diagnosis of a preexcitation syndrome with conduction disorders. This can lead to diagnostic and therapeutic dilemmas in the context of syncope. PMID:25114686
Ortigosa, Nuria; Pérez-Roselló, Víctor; Donoso, Víctor; Osca, Joaquín; Martínez-Dolz, Luis; Fernández, Carmen; Galbis, Antonio
2018-04-01
Cardiac resynchronization therapy (CRT) is an effective treatment for those patients with severe heart failure. Regrettably, there are about one third of CRT "non-responders", i.e. patients who have undergone this form of device therapy but do not respond to it, which adversely affects the utility and cost-effectiveness of CRT. In this paper, we assess the ability of a novel surface ECG marker to predict CRT response. We performed a retrospective exploratory study of the ECG previous to CRT implantation in 43 consecutive patients with ischemic (17) or non-ischemic (26) cardiomyopathy. We extracted the QRST complexes (consisting of the QRS complex, the S-T segment, and the T wave) and obtained a measure of their energy by means of spectral analysis. This ECG marker showed statistically significant lower values for non-responder patients and, joint with the duration of QRS complexes (the current gold-standard to predict CRT response), the following performances: 86% accuracy, 88% sensitivity, and 80% specificity. In this manner, the proposed ECG marker may help clinicians to predict positive response to CRT in a non-invasive way, in order to minimize unsuccessful procedures.
Chang, Anthony C
2012-03-01
The preparticipation screening for athlete participation in sports typically entails a comprehensive medical and family history and a complete physical examination. A 12-lead electrocardiogram (ECG) can increase the likelihood of detecting cardiac diagnoses such as hypertrophic cardiomyopathy, but this diagnostic test as part of the screening process has engendered considerable controversy. The pro position is supported by argument that international screening protocols support its use, positive diagnosis has multiple benefits, history and physical examination are inadequate, primary prevention is essential, and the cost effectiveness is justified. Although the aforementioned myriad of justifications for routine ECG screening of young athletes can be persuasive, several valid contentions oppose supporting such a policy, namely, that the sudden death incidence is very (too) low, the ECG screening will be too costly, the false-positive rate is too high, resources will be allocated away from other diseases, and manpower is insufficient for its execution. Clinicians, including pediatric cardiologists, have an understandable proclivity for avoiding this prodigious national endeavor. The controversy, however, should not be focused on whether an inexpensive, noninvasive test such as an ECG should be mandated but should instead be directed at just how these tests for young athletes can be performed in the clinical imbroglio of these disease states (with variable genetic penetrance and phenotypic expression) with concomitant fiscal accountability and logistical expediency in this era of economic restraint. This monumental endeavor in any city or region requires two crucial elements well known to business scholars: implementation and execution. The eventual solution for the screening ECG dilemma requires a truly innovative and systematic approach that will liberate us from inadequate conventional solutions. Artificial intelligence, specifically the process termed "machine learning" and "neural networking," involves complex algorithms that allow computers to improve the decision-making process based on repeated input of empirical data (e.g., databases and ECGs). These elements all can be improved with a national database, evidence-based medicine, and in the near future, innovation that entails a Kurzweilian artificial intelligence infrastructure with machine learning and neural networking that will construct the ultimate clinical decision-making algorithm.
Study of heart-brain interactions through EEG, ECG, and emotions
NASA Astrophysics Data System (ADS)
Ramasamy, Mouli; Varadan, Vijay K.
2017-04-01
Neurocardiology is the exploration of neurophysiological, neurological and neuroanatomical facets of neuroscience's influence in cardiology. The paraphernalia of emotions on the heart and brain are premeditated because of the interaction between the central and peripheral nervous system. This is an investigative attempt to study emotion based neurocardiology and the factors that influence this phenomenon. The factors include: interaction between sleep EEG (electroencephalogram) and ECG (electrocardiogram), relationship between emotion and music, psychophysiological coherence between the heart and brain, emotion recognition techniques, and biofeedback mechanisms. Emotions contribute vitally to the mundane life and are quintessential to a numerous biological and everyday-functional modality of a human being. Emotions are best represented through EEG signals, and to a certain extent, can be observed through ECG and body temperature. Confluence of medical and engineering science has enabled the monitoring and discrimination of emotions influenced by happiness, anxiety, distress, excitement and several other factors that influence the thinking patterns and the electrical activity of the brain. Similarly, HRV (Heart Rate Variability) widely investigated for its provision and discerning characteristics towards EEG and the perception in neurocardiology.
Multi-window detection for P-wave in electrocardiograms based on bilateral accumulative area.
Chen, Riqing; Huang, Yingsong; Wu, Jian
2016-11-01
P-wave detection is one of the most challenging aspects in electrocardiograms (ECGs) due to its low amplitude, low frequency, and variable waveforms. This work introduces a novel multi-window detection method for P-wave delineation based on the bilateral accumulative area. The bilateral accumulative area is calculated by summing the areas covered by the P-wave curve with left and right sliding windows. The onset and offset of a positive P-wave correspond to the local maxima of the area detector. The position drift and difference in area variation of local extreme points with different windows are used to systematically combine multi-window and 12-lead synchronous detection methods, which are used to screen the optimization boundary points from all extreme points of different window widths and adaptively match the P-wave location. The proposed method was validated with ECG signals from various databases, including the Standard CSE Database, T-Wave Alternans Challenge Database, PTB Diagnostic ECG Database, and the St. Petersburg Institute of Cardiological Technics 12-Lead Arrhythmia Database. The average sensitivity Se was 99.44% with a positive predictivity P+ of 99.37% for P-wave detection. Standard deviations of 3.7 and 4.3ms were achieved for the onset and offset of P-waves, respectively, which is in agreement with the accepted tolerances required by the CSE committee. Compared with well-known delineation methods, this method can achieve high sensitivity and positive predictability using a simple calculation process. The experiment results suggest that the bilateral accumulative area could be an effective detection tool for ECG signal analysis. Copyright © 2016 Elsevier Ltd. All rights reserved.
2013-01-01
Background Identifying the emotional state is helpful in applications involving patients with autism and other intellectual disabilities; computer-based training, human computer interaction etc. Electrocardiogram (ECG) signals, being an activity of the autonomous nervous system (ANS), reflect the underlying true emotional state of a person. However, the performance of various methods developed so far lacks accuracy, and more robust methods need to be developed to identify the emotional pattern associated with ECG signals. Methods Emotional ECG data was obtained from sixty participants by inducing the six basic emotional states (happiness, sadness, fear, disgust, surprise and neutral) using audio-visual stimuli. The non-linear feature ‘Hurst’ was computed using Rescaled Range Statistics (RRS) and Finite Variance Scaling (FVS) methods. New Hurst features were proposed by combining the existing RRS and FVS methods with Higher Order Statistics (HOS). The features were then classified using four classifiers – Bayesian Classifier, Regression Tree, K- nearest neighbor and Fuzzy K-nearest neighbor. Seventy percent of the features were used for training and thirty percent for testing the algorithm. Results Analysis of Variance (ANOVA) conveyed that Hurst and the proposed features were statistically significant (p < 0.001). Hurst computed using RRS and FVS methods showed similar classification accuracy. The features obtained by combining FVS and HOS performed better with a maximum accuracy of 92.87% and 76.45% for classifying the six emotional states using random and subject independent validation respectively. Conclusions The results indicate that the combination of non-linear analysis and HOS tend to capture the finer emotional changes that can be seen in healthy ECG data. This work can be further fine tuned to develop a real time system. PMID:23680041
Gibbons, Raymond J; Carryer, Damita; Liu, Hongfang; Brady, Peter A; Askew, J Wells; Hodge, David; Ammash, Naser; Ebbert, Jon O; Roger, Veronique L
2015-11-01
To determine how often unnecessary resting echocardiograms that are "not recommended" by clinical practice guidelines are performed in patients with stable chest pain and normal resting electrocardiograms (ECGs). We performed a retrospective search of electronic medical records of all outpatients seen at Mayo Clinic Rochester from January 1, 2010, through December 31, 2013, to identify residents of Olmsted County, Minnesota, with stable chest pain and known or suspected coronary artery disease who underwent resting echocardiography and had normal resting ECGs and no other indication for echocardiography. Of the 8280 outpatients from Olmsted County who were evaluated at Mayo Clinic Rochester with chest pain, 590 (7.1%) had resting echocardiograms. Ninety-two of these 590 patients (15.6%) had normal resting ECGs. Thirty-three of these 92 patients (35.9%) had other indications for echocardiography. The remaining 59 patients (10.0% of all echocardiograms and 0.7% of all patients) had normal resting ECGs and no other indication for echocardiography. Fifty-seven of these 59 patients (96.6%) had normal echocardiograms. Thirteen of these 59 echocardiograms (22.0%) were "preordered" before the provider (physicians, nurses, physician assistants) visit. The overall rate of echocardiography in Olmsted County outpatients with chest pain seen at Mayo Clinic Rochester is low. Only 1 in 10 of these echocardiograms was performed in violation of the class III recommendation in the American College of Cardiology Foundation/American Heart Association guidelines for the management of stable angina. These unnecessary echocardiograms were almost always normal. The rate of unnecessary echocardiograms could be decreased by eliminating preordering. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Fabregat-Andres, Oscar; Munoz-Macho, Adolfo; Adell-Beltran, Guillermo; Ibanez-Catala, Xavier; Macia, Agustin; Facila, Lorenzo
2014-08-01
Prevention of cardiac events during competitive sports is fundamental. New technologies with remote monitoring systems integrated into clothing could facilitate the screening of heart disease. Our aim was to evaluate the feasibility of Nuubo system during a field stress test performed by soccer players, comparing results with treadmill ergospirometry as test reference. Nineteen male professional soccer players (19.2 ± 1.6 years) were studied. Wireless electrocardiographic monitoring during a Yo-Yo intermittent recovery test level 1 in soccer field and subsequent analysis of arrhythmias were firstly performed. Subsequently, in a period no longer than 4 weeks, each player underwent cardiopulmonary exercise testing in hospital. During Yo-Yo test, electrocardiogram (ECG) signal was interpretable in 16 players (84.2%). In the other three players, ECG artifacts did not allow a proper analysis. Estimation of maximum oxygen consumption was comparable between two exercise tests (VO 2 max 53.3 ± 2.4 vs. 53.7 ± 3.0 mL/kg/min for Yo-Yo test and ergometry respectively; intra-class correlation coefficient 0.84 (0.63 - 0.93), P < 0.001). No arrhythmias were detected in any player during both tests. The use of Nuubo's technology allows an accurate single-lead electrocardiographic recording and estimation of reliable performance variables during exercise testing in field, and provides a new perspective to cardiac remote monitoring in collective sports.
Blood pulse wave velocity measured by photoacoustic microscopy
NASA Astrophysics Data System (ADS)
Yeh, Chenghung; Hu, Song; Maslov, Konstantin; Wang, Lihong V.
2013-03-01
Blood pulse wave velocity (PWV) is an important indicator for vascular stiffness. In this letter, we present electrocardiogram-synchronized photoacoustic microscopy for in vivo noninvasive quantification of the PWV in the peripheral vessels of mice. Interestingly, strong correlation between blood flow speed and ECG were clearly observed in arteries but not in veins. PWV is measured by the pulse travel time and the distance between two spot of a chose vessel, where simultaneously recorded electrocardiograms served as references. Statistical analysis shows a linear correlation between the PWV and the vessel diameter, which agrees with known physiology. Keywords: photoacoustic microscopy, photoacoustic spectroscopy, bilirubin, scattering medium.
Barbagelata, Alejandro; Di Carli, Marcelo F; Califf, Robert M; Garg, Jyotsna; Birnbaum, Yochai; Grinfeld, Liliana; Gibbons, Raymond J; Granger, Christopher B; Goodman, Shaun G; Wagner, Galen S; Mahaffey, Kenneth W
2005-10-01
Noninvasive methods are needed to evaluate reperfusion success in patients with acute myocardial infarction (MI). The AMISTAD trial was analyzed to compare MI size and myocardial salvage determined by electrocardiogram (ECG) with technetium Tc 99m sestamibi single-photon emission computerized tomography (SPECT) imaging. Of 236 patients enrolled in AMISTAD, 166 (70 %) with no ECG confounding factors and no prior MI were included in this analysis. Of these, group 1 (126 patients, 53%) had final infarct size (FIS) available by both ECG and SPECT. Group 2 (56 patients, 24%) had myocardium at risk, FIS, and salvage index (SI) assessed by both SPECT and ECG techniques. Aldrich/Clemmensen scores for myocardium at risk and the Selvester QRS score for final MI size were used. Salvage index was calculated as follows: SI = (myocardium at risk-FIS)/(myocardium at risk). In group 1, FIS was 15% (6, 24) as measured by ECG and 11% (2, 27) as measured by SPECT. In the adenosine group, FIS was 12% (6, 21) and 11% (2, 22). In the placebo group, FIS was 16.5% (7.5, 24) and 11.5% (3.0, 38.5) by ECG and SPECT, respectively. The overall correlation between SPECT and ECG for FIS was 0.58 (P = .0001): 0.60 in the placebo group (P = .0001) and 0.54 (P = .0001) in the adenosine group. In group 2, myocardium at risk was 23% (17, 30) and 26% (10, 50) with ECG and SPECT, respectively (P = .0066). Final infarct size was 17% (6, 21) and 12% (1, 24) (P < .0001). The SI was 29% (-7, 57) and 46% (15, 79) with ECG and SPECT, respectively (P = .0510). The ECG measurement of infarct size has a moderate relationship with SPECT infarct size measurements in the population with available assessments. This ECG algorithm must further be validated on clinical outcomes.
Implementation of a portable device for real-time ECG signal analysis.
Jeon, Taegyun; Kim, Byoungho; Jeon, Moongu; Lee, Byung-Geun
2014-12-10
Cardiac disease is one of the main causes of catastrophic mortality. Therefore, detecting the symptoms of cardiac disease as early as possible is important for increasing the patient's survival. In this study, a compact and effective architecture for detecting atrial fibrillation (AFib) and myocardial ischemia is proposed. We developed a portable device using this architecture, which allows real-time electrocardiogram (ECG) signal acquisition and analysis for cardiac diseases. A noisy ECG signal was preprocessed by an analog front-end consisting of analog filters and amplifiers before it was converted into digital data. The analog front-end was minimized to reduce the size of the device and power consumption by implementing some of its functions with digital filters realized in software. With the ECG data, we detected QRS complexes based on wavelet analysis and feature extraction for morphological shape and regularity using an ARM processor. A classifier for cardiac disease was constructed based on features extracted from a training dataset using support vector machines. The classifier then categorized the ECG data into normal beats, AFib, and myocardial ischemia. A portable ECG device was implemented, and successfully acquired and processed ECG signals. The performance of this device was also verified by comparing the processed ECG data with high-quality ECG data from a public cardiac database. Because of reduced computational complexity, the ARM processor was able to process up to a thousand samples per second, and this allowed real-time acquisition and diagnosis of heart disease. Experimental results for detection of heart disease showed that the device classified AFib and ischemia with a sensitivity of 95.1% and a specificity of 95.9%. Current home care and telemedicine systems have a separate device and diagnostic service system, which results in additional time and cost. Our proposed portable ECG device provides captured ECG data and suspected waveform to identify sporadic and chronic events of heart diseases. This device has been built and evaluated for high quality of signals, low computational complexity, and accurate detection.
Lowres, Nicole; Neubeck, Lis; Salkeld, Glenn; Krass, Ines; McLachlan, Andrew J; Redfern, Julie; Bennett, Alexandra A; Briffa, Tom; Bauman, Adrian; Martinez, Carlos; Wallenhorst, Christopher; Lau, Jerrett K; Brieger, David B; Sy, Raymond W; Freedman, S Ben
2014-06-01
Atrial fibrillation (AF) causes a third of all strokes, but often goes undetected before stroke. Identification of unknown AF in the community and subsequent anti-thrombotic treatment could reduce stroke burden. We investigated community screening for unknown AF using an iPhone electrocardiogram (iECG) in pharmacies, and determined the cost-effectiveness of this strategy.Pharmacists performedpulse palpation and iECG recordings, with cardiologist iECG over-reading. General practitioner review/12-lead ECG was facilitated for suspected new AF. An automated AF algorithm was retrospectively applied to collected iECGs. Cost-effectiveness analysis incorporated costs of iECG screening, and treatment/outcome data from a United Kingdom cohort of 5,555 patients with incidentally detected asymptomatic AF. A total of 1,000 pharmacy customers aged ≥65 years (mean 76 ± 7 years; 44% male) were screened. Newly identified AF was found in 1.5% (95% CI, 0.8-2.5%); mean age 79 ± 6 years; all had CHA2DS2-VASc score ≥2. AF prevalence was 6.7% (67/1,000). The automated iECG algorithm showed 98.5% (CI, 92-100%) sensitivity for AF detection and 91.4% (CI, 89-93%) specificity. The incremental cost-effectiveness ratio of extending iECG screening into the community, based on 55% warfarin prescription adherence, would be $AUD5,988 (€3,142; $USD4,066) per Quality Adjusted Life Year gained and $AUD30,481 (€15,993; $USD20,695) for preventing one stroke. Sensitivity analysis indicated cost-effectiveness improved with increased treatment adherence.Screening with iECG in pharmacies with an automated algorithm is both feasible and cost-effective. The high and largely preventable stroke/thromboembolism risk of those with newly identified AF highlights the likely benefits of community AF screening. Guideline recommendation of community iECG AF screening should be considered.