An Effective Technique for Enhancing an Intrauterine Catheter Fetal Electrocardiogram
NASA Astrophysics Data System (ADS)
Horner, Steven L.; Holls, William M.
2003-12-01
Physician can obtain fetal heart rate, electrophysiological information, and uterine contraction activity for determining fetal status from an intrauterine catheters electrocardiogram with the maternal electrocardiogram canceled. In addition, the intrauterine catheter would allow physicians to acquire fetal status with one non-invasive to the fetus biosensor as compared to invasive to the fetus scalp electrode and intrauterine pressure catheter used currently. A real-time maternal electrocardiogram cancellation technique of the intrauterine catheters electrocardiogram will be discussed along with an analysis for the methods effectiveness with synthesized and clinical data. The positive results from an original detailed subjective and objective analysis of synthesized and clinical data clearly indicate that the maternal electrocardiogram cancellation method was found to be effective. The resulting intrauterine catheters electrocardiogram from effectively canceling the maternal electrocardiogram could be used for determining fetal heart rate, fetal electrocardiogram electrophysiological information, and uterine contraction activity.
Electrocardiogram artifact caused by rigors mimicking narrow complex tachycardia: a case report.
Matthias, Anne Thushara; Indrakumar, Jegarajah
2014-02-04
The electrocardiogram (ECG) is useful in the diagnosis of cardiac and non-cardiac conditions. Rigors due to shivering can cause electrocardiogram artifacts mimicking various cardiac rhythm abnormalities. We describe an 80-year-old Sri Lankan man with an abnormal electrocardiogram mimicking narrow complex tachycardia during the immediate post-operative period. Electrocardiogram changes caused by muscle tremor during rigors could mimic a narrow complex tachycardia. Identification of muscle tremor as a cause of electrocardiogram artifact can avoid unnecessary pharmacological and non-pharmacological intervention to prevent arrhythmias.
Wang, Gaopin; Liu, Renguang; Chang, Qinghua; Xu, Zhaolong; Zhang, Yingjie; Pan, Dianzhu
2017-03-15
The micro waveform of His bundle potential can't be recorded beat-to-beat on surface electrocardiogram yet. We have found that the micro-wavelets before QRS complex may be related to atrioventricular conduction system potentials. This study is to explore the possibility of His bundle potential can be noninvasively recorded on surface electrocardiogram. We randomized 65 patients undergoing radiofrequency catheter ablation of paroxysmal superventricular tachycardia (exclude overt Wolff-Parkinson-White syndrome) to receive "conventional electrocardiogram" and "new electrocardiogram" before the procedure. His bundle electrogram was collected during the procedure. Comparative analysis of PA s (PA interval recorded on surface electrocardiogram), AH s (AH interval recorded on surface electrocardiogram) and HV s (HV interval recorded on surface electrocardiogram) interval recorded on surface "new electrocardiogram" and PA, AH, HV interval recorded on His bundle electrogram was investigated. There was no difference (P > 0.05) between groups in HV s interval (49.63 ± 6.19 ms) and HV interval (49.35 ± 6.49 ms). Results of correlational analysis found that HV S interval was significantly positively associated with HV interval (r = 0.929; P < 0.01). His bundle potentials can be noninvasively recorded on surface electrocardiogram. Noninvasive His bundle potential tracing might represent a new method for locating the site of atrioventricular block and identifying the origin of a wide QRS complex.
[Advances of portable electrocardiogram monitor design].
Ding, Shenping; Wang, Yinghai; Wu, Weirong; Deng, Lingli; Lu, Jidong
2014-06-01
Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.
Longitudinal Health Research in the U.S. Navy.
1979-12-01
while morbidity variables would be the presence or absence of a specific disease or condition, or perhaps a continuous response such S as level of...Cardiovascular routine electrocardiogram * * * * startle electrocardiogram * computer processed electrocardiogram * * exercise electrocardiogram...basal metabolic rate * other * * Anthropometry somatotype * * * measurements (in addition to height & weight) e * * Teleoroentgenograms
Analysis of electrocardiogram in chronic obstructive pulmonary disease patients.
Lazović, Biljana; Svenda, Mirjana Zlatković; Mazić, Sanja; Stajić, Zoran; Delić, Marina
2013-01-01
Chronic obstructive pulmonary disease is the fourth leading cause of mortality worldwide. It is defined as a persistent airflow limitation usually progressive and not fully reversible to treatment. The diagnosis of chronic obstructive pulmonary disease and severity of disease is confirmed by spirometry. Chronic obstructive pulmonary disease produces electrical changes in the heart which shows characteristic electrocardiogram pattern. The aim of this study was to observe and evaluate diagnostic values of electrocardiogram changes in chronic obstructive pulmonary disease patients with no other comorbidity. We analyzed 110 electrocardiogram findings in clinically stable chronic obstructive pulmonary disease patients and evaluated the forced expiratory volume in the first second, ratio of forces expiratory volume in the first second to the fixed vital capacity, chest radiographs and electrocardiogram changes such as p wave height, QRS axis and voltage, right bundle branch block, left bundle branch block, right ventricular hypertrophy, T wave inversion in leads V1-V3, S1S2S3 syndrome, transition zone in praecordial lead and QT interval. We found electrocardiogram changes in 64% patients, while 36% had normal electrocardiogram. The most frequent electrocardiogram changes observed were transition zone (76.36%) low QRS (50%) and p pulmonale (14.54%). Left axis deviation was observed in 27.27% patients. Diagnostic values of electrocardiogram in patients with chronic obstructive pulmonary disease suggest that chronic obstructive pulmonary disease patients should be screened electrocardiographically in addition to other clinical investigations.
NASA Astrophysics Data System (ADS)
Osaka, Motohisa; Murata, Hiroshige; Tateoka, Katsuhiko; Katoh, Takao
2007-07-01
Some cases of traffic accidents are assumed to be due to the occurrences of cardiac events during driving, which are thought to be induced by imbalance of autonomic nervous activities. These can be measured by analyzing heart rate variability. Therefore, we developed a new system of steering-wheel electrocardiogram with a soft-ware to remove noises. We compared the trends of sympathetic and parasympathetic nerve activities measured from the steering-wheel electrocardiograms with those recorded simultaneously from chest leads. For each parameter of instantaneous heart rate, low- or high-frequency component of heart rate variability in all the cases, the trend from the steering-wheel electrocardiogram resembled that from the chest-lead electrocardiogram. In 3 of 7 subjects, the trend of LF/HF showed a strong relationship between the steering-wheel electrocardiogram and the chest-lead electrocardiogram. Our system will open doors to a new strategy to keep a driver out of a risk by notifying it while driving.
ELECTROCARDIOGRAMS BY TELEMETRY
Winsor, Travis; Sibley, E. A.; Fisher, E. K.
1961-01-01
Radiocardiography makes it possible to transmit an electrocardiogram by air from patient to recording device. The distance of transmission may be a few feet, as in a physician's office; or it may be many miles, as when transmitting electrocardiograms from aircraft, rockets or satellites to the earth. The radiocardiographic method has the advantage of versatility, simplicity, freedom of movement for the patient and high amplitude, and is especially suited for recording electrocardiograms during exercise. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5. PMID:13785896
Using the BBC Microcomputer to Teach the Electrocardiogram to Biology Students.
ERIC Educational Resources Information Center
Dewhurst, D. G.; And Others
1990-01-01
Described are two methods which use microcomputers to illustrate the use of the electrocardiogram and the function of the heart. Included are a simulation and a method of collecting live electrocardiograms. Hardware, software, and the use of these systems are discussed. (CW)
Li, Y H; Yu, S F; Gu, G Z; Chen, G S; Zhou, W H; Wu, H; Jiao, J
2016-02-20
To investigate the factors influencing the electrocardiogram results in the workers exposed to noise in steel-making and steel rolling workshops of an iron and steel plant. From September to December, 2013, cluster sampling was used to select 3 150 workers exposed to noise in the steel-making and steel-rolling workshops of an iron and steel plant, and a questionnaire survey and physical examinations were performed. The number of valid workers was 2 915, consisting of 1 606 workers in the steel-rolling workshop and 1 309 in the steel-making workshop. The electrocardiogram results of the workers in steel-making and steel-rolling workshops were analyzed. The overall abnormal rate of electrocardiogram was 26.35%, and the workers in the steel-making workshop had a significantly higher abnormal rate of electrocardiogram than those in the steel-rolling workshop(32.24% vs 21.54%, P<0.05). Male workers had a significantly higher abnormal rate of electrocardiogram than female workers(27.59% vs 18.61%, P<0.05). The workers with a drinking habit had a significantly higher abnormal rate of electrocardiogram than those who did not drink(28.17% vs 23.75%, P<0.05). The workers exposed to high temperature had a significantly higher abnormal rate of electrocardiogram than those who were not exposed to high temperature(29.43% vs 20.14%, P<0.05). The abnormal rates of electrocardiogram in the workers with cumulative noise exposure levels of <90, 90~94, 95~99, 100~104, and 105~113 dB(A)·year were 21.21%, 21.76%, 26.50%, 27.27%, and 32.16%, respectively, with significant differences between any two groups(P<0.05). The multivariate logistic regression analysis showed that a cumulative noise exposure of 105-113 dB(A)·year(OR=1.36, 95% CI: 1.03~1.80), a drinking habit(OR=1.20, 95% CI: 1.01~1.43), and high temperature(OR=1.60, 95% CI: 1.32~1.92) were the risk factors for abnormal electrocardiogram results. High cumulative noise exposure, alcohol consumption, and high temperature may affect the abnormal rate of electrocardiogram in the workers exposed to noise in steel-making and steel-rolling workshops.
Ker, James
2012-07-12
During the past century the electrocardiogram (ECG) has established itself as an integral part of the cardiovascular examination. Since the first direct recordings of cardiac potentials by Waller in 1887, to the invention of the string galvanometer by Willem Einthoven in 1901, to use in the clinic by 1910, the electrocardiogram has become the most widely used clinical tool in the diagnosis of virtually every type of heart disease. Currently up to 20 million ECGs are performed annually in the United States alone. However, in this era of readily available echocardiography, an important caveat in the interpretation of the electrocardiogram has emerged: variants of intracardiac structures which might mimic disease on the ECG. In this perspective various structural variants of intracardiac structures, specifically variants of papillary muscles and subaortic muscular bands, will be shown, together with their associated electrocardiographic changes, mimicking disease. It is concluded that in this era of readily available echocardiography, the electrocardiogram should be interpreted echocardiographically in instances where intricate variations are seen on the surface electrocardiogram. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Chaĭkovskiĭ, I A; Baum, O V; Popov, L A; Voloshin, V I; Budnik, N N; Frolov, Iu A; Kovalenko, A S
2014-01-01
While discussing the diagnostic value of the single channel electrocardiogram a set of theoretical considerations emerges inevitably, one of the most important among them is the question about dependence of the electrocardiogram parameters from the direction of electrical axis of heart. In other words, changes in what of electrocardiogram parameters are in fact liable to reflect pathological processes in myocardium, and what ones are determined by extracardiac factors, primarily by anatomic characteristics of patients. It is arguable that while analyzing electrocardiogram it is necessary to orient to such physiologically based informative indexes as ST segment displacement. Also, symmetry of the T wave shape is an important parameter which is independent of patients anatomic features. The results obtained are of interest for theoretical and applied aspects of the biophysics of the cardiac electric field.
Cho, Jae Hyung; Selen, Mats A; Kocheril, Abraham G
2015-08-11
The 12-lead electrocardiographic screening for the prevention of sudden cardiac death in young competitive athletes is not cost-effective and thus not routinely recommended. We investigate whether a less expensive wireless electrocardiographic transmission device can be used to screen for the prevention of sudden cardiac death in this population. During pre-participation screening, twenty college football players underwent two electrocardiograms: a conventional 12-lead electrocardiogram and a wireless 9-lead electrocardiogram. We compared several electrocardiographic parameters (QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria, ST deviation and corrected QT interval) to determine the correlation. The QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria and corrected QT interval exhibited significant correlation between the two types of electrocardiograms (correlation coefficient 0.878, 0.630, 0.770 and 0.847, respectively with P values of 0.01, 0.003, 0.01 and 0.01, respectively). ST deviation in V1 was weakly correlated between the two types of electrocardiograms without statistical significance (correlation coefficient 0.360 with a P value of 0.119). Our newly developed wireless 9-lead electrocardiogram demonstrated significant correlations with a conventional 12-lead electrocardiogram in terms of QRS duration, left ventricular hypertrophy and corrected QT interval.
Hernández-Padilla, José M; Granero-Molina, José; Márquez-Hernández, Verónica V; Suthers, Fiona; López-Entrambasaguas, Olga M; Fernández-Sola, Cayetano
2017-06-01
Rapid and accurate interpretation of cardiac arrhythmias by nurses has been linked with safe practice and positive patient outcomes. Although training in electrocardiogram rhythm recognition is part of most undergraduate nursing programmes, research continues to suggest that nurses and nursing students lack competence in recognising cardiac rhythms. In order to promote patient safety, nursing educators must develop valid and reliable assessment tools that allow the rigorous assessment of this competence before nursing students are allowed to practise without supervision. The aim of this study was to develop and psychometrically evaluate a toolkit to holistically assess competence in electrocardiogram rhythm recognition. Following a convenience sampling technique, 293 nursing students from a nursing faculty in a Spanish university were recruited for the study. The following three instruments were developed and psychometrically tested: an electrocardiogram knowledge assessment tool (ECG-KAT), an electrocardiogram skills assessment tool (ECG-SAT) and an electrocardiogram self-efficacy assessment tool (ECG-SES). Reliability and validity (content, criterion and construct) of these tools were meticulously examined. A high Cronbach's alpha coefficient demonstrated the excellent reliability of the instruments (ECG-KAT=0.89; ECG-SAT=0.93; ECG-SES=0.98). An excellent context validity index (scales' average content validity index>0.94) and very good criterion validity were evidenced for all the tools. Regarding construct validity, principal component analysis revealed that all items comprising the instruments contributed to measure knowledge, skills or self-efficacy in electrocardiogram rhythm recognition. Moreover, known-groups analysis showed the tools' ability to detect expected differences in competence between groups with different training experiences. The three-instrument toolkit developed showed excellent psychometric properties for measuring competence in electrocardiogram rhythm recognition.
[Practical experience about the compatibility of PDF converter in ECG information system].
Yang, Gang; Lu, Weishi; Zhou, Jiacheng
2009-11-01
To find a way to view ECG from different manufacturers in electrocardiogram information system. Different format ECG data were transmitted to ECG center by different ways. Corresponding analysis software was used to make the diagnosis reports in the center. Then we use PDF convert to change all ECG reports into PDF format. The electrocardiogram information system manage these PDF format ECG data for clinic user. The ECG reports form several major ECG manufacturers were transformed to PDF format successfully. In the electrocardiogram information system it is freely to view the ECG figure. PDF format ECG report is a practicable way to solve the compatibility problem in electrocardiogram information system.
Mathematical model with autoregressive process for electrocardiogram signals
NASA Astrophysics Data System (ADS)
Evaristo, Ronaldo M.; Batista, Antonio M.; Viana, Ricardo L.; Iarosz, Kelly C.; Szezech, José D., Jr.; Godoy, Moacir F. de
2018-04-01
The cardiovascular system is composed of the heart, blood and blood vessels. Regarding the heart, cardiac conditions are determined by the electrocardiogram, that is a noninvasive medical procedure. In this work, we propose autoregressive process in a mathematical model based on coupled differential equations in order to obtain the tachograms and the electrocardiogram signals of young adults with normal heartbeats. Our results are compared with experimental tachogram by means of Poincaré plot and dentrended fluctuation analysis. We verify that the results from the model with autoregressive process show good agreement with experimental measures from tachogram generated by electrical activity of the heartbeat. With the tachogram we build the electrocardiogram by means of coupled differential equations.
NASA Astrophysics Data System (ADS)
Rendon-Morales, E.; Prance, R. J.; Prance, H.; Aviles-Espinosa, R.
2015-11-01
In this letter, we report the continuous detection of the cardiac electrical activity in embryonic zebrafish using a non-invasive approach. We present a portable and cost-effective platform based on the electric potential sensing technology, to monitor in vivo electrocardiogram activity from the zebrafish heart. This proof of principle demonstration shows how electrocardiogram measurements from the embryonic zebrafish may become accessible by using electric field detection. We present preliminary results using the prototype, which enables the acquisition of electrophysiological signals from in vivo 3 and 5 days-post-fertilization zebrafish embryos. The recorded waveforms show electrocardiogram traces including detailed features such as QRS complex, P and T waves.
Manyari, D. E.; Milliken, J. A.; Colwell, B. T.; Burggraf, G. W.
1978-01-01
To determine the sensitivity and specificity of chest roentgenography and electrocardiography in the detection of pericardial effusion, echocardiography was used as the diagnostic standard. Chest roentgenograms and electrocardiograms of 124 patients, 57 of whom had pericardial effusion, were read without knowledge of the echocardiographic interpretation. The sensitivity of roentgenographic diagnosis was low (20%), as was that of diagnosis from decreased voltage on the electrocardiogram (26%). The specificity of the chest roentgenogram was 89% and that of the low-voltage electrocardiogram 97%. The high specificity of the low-voltage electrocardiogram may have been due in part to the exclusion of obese and emphysematous subjects from the study. When cardiomegaly detected roentgenographically or a low-voltage electrocardiogram or both were considered as evidence of pericardial effusion, sensitivity improved to 82% but specificity declined to 29%. It is concluded the chest roentgenography and electrocardiography are unsatisfactory as screening investigations for the detection of pericardial effusion. Images FIG. 1 FIG. 2 FIG. 3 PMID:688146
Ratnayake, Eranda Chamara; Premaratne, Sandamali; Lokunarangoda, Niroshan; Fernando, Sanduni; Fernando, Nilanthi; Ponnamperuma, Chandrike; Santharaj, W Samuel
2015-04-30
Pneumopyopericardium is a rare disease with poor prognosis. The usual presentation is with fever, shortness of breath and haemodynamic compromise. The Electrocardiogram changes associated with this disease entity would be similar to pericarditis such as concave shaped ST elevations in all leads with PR sagging. Pneumopyopericardium mimicking an acute ST Elevation Myocardial Infarction, with regional Electrocardiogram changes has hitherto not been described in world literature. We describe the case of a 48 year old native Sri Lankan man, presenting with chest pain and Electrocardiogram changes compatible with an Acute ST Elevation Myocardial Infarction, subsequently found to have Pneumopyopericardium secondary to an oesophageal tear. Retrospective history revealed repetitive vomiting due to heavy alcohol consumption, prior to presentation. It unfortunately led to a fatal outcome. Pneumopyopericardium may mimic an acute ST elevation myocardial infarction with associated regional Electrocardiogram changes. A high degree of suspicion should be maintained and an adequate history should always be obtained prior to any intervention in all ST Elevation Myocardial Infarction patients.
The electrocardiogram (ECG, EKG) is used extensively in the diagnosis of heart disease, ranging from congenital heart disease in ... and myocarditis in adults. Several different types of electrocardiogram exist.
Agreement in electrocardiogram interpretation in patients with septic shock.
Mehta, Sangeeta; Granton, John; Lapinsky, Stephen E; Newton, Gary; Bandayrel, Kristofer; Little, Anjuli; Siau, Chuin; Cook, Deborah J; Ayers, Dieter; Singer, Joel; Lee, Terry C; Walley, Keith R; Storms, Michelle; Cooper, Jamie; Holmes, Cheryl L; Hebert, Paul; Gordon, Anthony C; Presneill, Jeff; Russell, James A
2011-09-01
The reliability of electrocardiogram interpretation to diagnose myocardial ischemia in critically ill patients is unclear. In adults with septic shock, we assessed intra- and inter-rater agreement of electrocardiogram interpretation, and the effect of knowledge of troponin values on these interpretations. Prospective substudy of a randomized trial of vasopressin vs. norepinephrine in septic shock. Nine Canadian intensive care units. Adults with septic shock requiring at least 5 μg/min of norepinephrine for 6 hrs. Twelve-lead electrocardiograms were recorded before study drug, and 6 hrs, 2 days, and 4 days after study drug initiation. Two physician readers, blinded to patient data and group, independently interpreted electrocardiograms on three occasions (first two readings were blinded to patient data; third reading was unblinded to troponin). To calibrate and refine definitions, both readers initially reviewed 25 trial electrocardiograms representing normal to abnormal. Cohen's Kappa and the φ statistic were used to analyze intra- and inter-rater agreement. One hundred twenty-one patients (62.2 ± 16.5 yrs, Acute Physiology and Chronic Health Evaluation II 28.6 ± 7.7) had 373 electrocardiograms. Blinded to troponin, readers 1 and 2 interpreted 46.4% and 30.0% of electrocardiograms as normal, and 15.3% and 12.3% as ischemic, respectively. Intrarater agreement was moderate for overall ischemia (κ 0.54 and 0.58), moderate/good for "normal" (κ 0.69 and 0.55), fair to good for specific signs of ischemia (ST elevation, T inversion, and Q waves, reader 1 κ 0.40 to 0.69; reader 2 κ 0.56 to 0.70); and good/very good for atrial arrhythmias (κ 0.84 and 0.79) and bundle branch block (κ 0.88 and 0.79). Inter-rater agreement was fair for ischemia (κ 0.29), moderate for ST elevation (κ 0.48), T inversion (κ 0.52), and Q waves (κ 0.44), good for bundle branch block (κ 0.78), and very good for atrial arrhythmias (κ 0.83). Inter-rater agreement for ischemia improved from fair to moderate (κ 0.52, p = .028) when unblinded to troponin. In patients with septic shock, inter-rater agreement of electrocardiogram interpretation for myocardial ischemia was fair, and improved with troponin knowledge.
Electrocardiography: A Technologist's Guide to Interpretation.
Tso, Colin; Currie, Geoffrey M; Gilmore, David; Kiat, Hosen
2015-12-01
The nuclear medicine technologist works with electrocardiography when performing cardiac stress testing and gated cardiac imaging and when monitoring critical patients. To enhance patient care, basic electrocardiogram interpretation skills and recognition of key arrhythmias are essential for the nuclear medicine technologist. This article provides insight into the anatomy of an electrocardiogram trace, covers basic electrocardiogram interpretation methods, and describes an example case typical in the nuclear medicine environment. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
New micro waveforms firstly recorded on electrocardiogram in human.
Liu, Renguang; Chang, Qinghua; Chen, Juan
2015-10-01
In our study, not only the P-QRS-T waves but also the micro-wavelets before QRS complex (in P wave and PR segment) and after QRS complex (ST segment and upstroke of T wave) were first to be identified on surface electrocardiogram in human by the "new electrocardiogram" machine (model PHS-A10) according to conventional 12-lead electrocardiogram connection methods. By comparison to the conventional electrocardiogram in 100 cases of healthy individuals and several patients with arrhythmias, we have found that the wavelets before P wave theoretically reflected electrical activity of sinus node and the micro-wavelets before QRS complex may be related to atrioventricular conduction system (atrioventricular node, His bundle and bundle branch) potentials. Noninvasive atrioventricular node and His bundle potential tracing will contribute to differentiation of the origin of wide QRS and the location of the atrioventricular block. We also have found that the wavelets after QRS complex may be associated with phase 2 and 3 repolarization of ventricular action potential, which will further reveal ventricular repolarization changes. Copyright © 2015 Elsevier Ltd. All rights reserved.
... head, if head injury or bleeding is suspected ECG (electrocardiogram, to measure electrical activity in the heart) ... to amputation Alternative Names Intoxication - cocaine Images Electrocardiogram (ECG) References Aronson JK. Cocaine. In: Aronson JK, ed. ...
... x-ray CT scan of the chest Electrocardiogram (ECG or EKG) Echocardiogram These tests may show: Problems ... monitored for at least 24 hours. An electrocardiogram (ECG) will be done continually to check your heart ...
United in prevention-electrocardiographic screening for chronic obstructive pulmonary disease.
Lazovic, Biljana; Mazic, Sanja; Stajic, Zoran; Djelic, Marina; Zlatkovic-Svenda, Mirjana; Putnikovic, Biljana
2013-01-01
NONE DECLARED. P-wave abnormalities on the resting electrocardiogram have been associated with cardiovascular or pulmonary disease. So far, "Gothic" P wave and verticalization of the frontal plane axis is related to lung disease, particularly obstructive lung disease. We tested if inverted P wave in AVl as a lone criteria of P wave axis >70° could be screening tool for emphysema. 1095 routine electrocardiograms (ECGs) were reviewed which yielded 478 (82,1%) ECGs with vertical P-axis in sinus rhythm. Charts were reviewed for the diagnosis of COPD and emphysema based on medical history and pulmonary function tests. Electrocardiogram is very effective screening tool not only in cardiovascular field but in chronic obstructive pulmonary disease. The verticality of the P axis is usually immediately apparent, making electrocardiogram rapid screening test for emphysema.
... the esophagus and the stomach. Chest x-ray ECG (electrocardiogram, or heart tracing) Fluids by IV (through ... in the airways and lungs. Chest x-ray ECG (electrocardiogram, or heart tracing) Fluids by IV (through ...
Electrocardiogram Scanner-System Requirements
DOT National Transportation Integrated Search
1973-03-01
An experimental and analytical study has been conducted to establish the feasibility for scanning and digitizing electrocardiogram records. The technical requirements and relative costs for two systems are discussed herein. One is designed to automat...
Horiuchi, Toshinori; Noguchi, Teruo; Kurita, Naoko; Yamaguchi, Ayako; Takeda, Masafumi; Sha, Keiichi; Nagahata, Toshihiro
2016-01-01
We present two patients developing intraoperative massive bleeding and showed ischemic changes in the electrocardiogram and circulatory collapse accompanied by severe anemia owing to the delay of red blood cell concentrate transfusion. One patient underwent hepatectomy and the other pancreaticoduodenectomy. Their lowest hemoglobin concentration was around 2 g x dl(-1), and they showed ischemic changes in the electrocardiogram and severe decreases in blood pressure. The former received compatible red blood cell concentrate and the latter received uncrossmatched same blood group red blood cell concentrate immediately, and their electrocardiogram and blood pressure quickly improved. To avoid life-threatening anemia, emergency red blood cell concentrate transfusion including compatible different blood group transfusion should be applied for intraoperative massive bleeding.
ECG-ViEW II, a freely accessible electrocardiogram database
Park, Man Young; Lee, Sukhoon; Jeon, Min Seok; Yoon, Dukyong; Park, Rae Woong
2017-01-01
The Electrocardiogram Vigilance with Electronic data Warehouse II (ECG-ViEW II) is a large, single-center database comprising numeric parameter data of the surface electrocardiograms of all patients who underwent testing from 1 June 1994 to 31 July 2013. The electrocardiographic data include the test date, clinical department, RR interval, PR interval, QRS duration, QT interval, QTc interval, P axis, QRS axis, and T axis. These data are connected with patient age, sex, ethnicity, comorbidities, age-adjusted Charlson comorbidity index, prescribed drugs, and electrolyte levels. This longitudinal observational database contains 979,273 electrocardiograms from 461,178 patients over a 19-year study period. This database can provide an opportunity to study electrocardiographic changes caused by medications, disease, or other demographic variables. ECG-ViEW II is freely available at http://www.ecgview.org. PMID:28437484
Electrocardiogram interpretation in general practice: relevance to prehospital thrombolysis.
McCrea, W A; Saltissi, S
1993-01-01
OBJECTIVE--To assess, in the context of their possible role in prehospital thrombolysis, the ability of general practitioners to recognise acute transmural myocardial ischaemia/infarction on an electrocardiogram. DESIGN--150 doctors (every fifth name) were selected from the alphabetical list of 750 on Merseyside general practitioner register and without prior warning were asked to interpret a series of six 12 lead electrocardiograms. Three of these showed acute transmural ischaemia/infarction, one was normal, and two showed non-acute abnormalities. Details of doctors' ages, postgraduate training, and clinical practice were sought. SETTING--General practitioners' surgeries and postgraduate centres within the Merseyside area. PARTICIPANTS--106 general practitioners (mean age 45 years) agreed to participate. MAIN OUTCOME MEASURE--Accuracy of general practitioners' interpretations of the six electrocardiograms. RESULTS--82% of general practitioners correctly recognised a normal electrocardiogram. Recognition of acute abnormalities was less reliable. Between 33% and 61% correctly identified acute transmural ischaemia/infarction depending on the specific trace presented. Accurate localisation of the site of the infarct was achieved only by between 8% and 30% of participants, while between 22% and 25% correctly interpreted non-acute abnormalities. Neither routine use of electrocardiography nor postgraduate hospital experience in general medicine was associated with significantly greater expertise. CONCLUSION--The current level of proficiency of a sample of general practitioners in the Merseyside area in recognising acute transmural ischaemia/infarction on an electrocardiogram suggests that refresher training is needed if general practitioners are to give prehospital thrombolysis. Images PMID:8398491
Cygan, Lukasz D; Weizberg, Moshe; Hahn, Barry
2016-09-01
Electrocardiography findings in patients with pulmonary embolism have been investigated since 1935. As medicine has evolved, more effective modalities have surpassed the electrocardiogram in diagnostic utility. Despite the advent of these other modalities, the diagnosis of pulmonary embolism remains elusive and the prognosis is variable amongst each clinical presentation of its pathology. After presenting a case of a resolving S1Q3T3 in subsequent electrocardiogram findings of a patient with pulmonary embolism, this literature review will provide information on a 21-point electrocardiogram scoring system that helps the emergency physician stratify the risk of a patient with an acute presentation of pulmonary embolism. Why should emergency care staff be aware of this? Given the time-sensitive nature of diagnosis and appropriate treatment, Electrocardiogram continues to be a tool in the assessment of patients with a clinical suspicion of pulmonary embolism. Based on the information provided, 21-point electrocardiogram score has been shown to have strong usefulness in assessing prognosis of patients presenting with acute pulmonary embolism. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Electrocardiogram as an Example of Electrostatics
ERIC Educational Resources Information Center
Hobbie, Russell K.
1973-01-01
Develops a simplified electrostatic model of the heart with conduction within the torso neglected to relate electrocardiogram patterns to the charge distribution within the myocardium. Suggests its application to explanation of Coulomb's law in general physics. (CC)
Biotelemetry for Monitoring Electrocardiograms during Athletic Events and Stress Tests
ERIC Educational Resources Information Center
Mitchell, B. W.; Thomasson, G. O.
1975-01-01
This article discusses a study attempting to determine if a biotelemetry system developed for use on chickens could be suitable for monitoring electrocardiograms of humans during exercise. Techniques for its use are reviewed. (JS)
... A telltale abnormality — called a type 1 Brugada ECG pattern — is detected by an electrocardiogram (ECG) test. Brugada syndrome is much more common in ... syndrome is an abnormal pattern on an electrocardiogram (ECG) called a type 1 Brugada ECG pattern. You ...
Fong, Allan; Mittu, Ranjeev; Ratwani, Raj; Reggia, James
2014-01-01
Alarm fatigue caused by false alarms and alerts is an extremely important issue for the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the staff and hospital systems better classify a patient's waveforms and subsequent alarms. This paper explores the use of Echo State Networks, a specific type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network architectures are designed and evaluated. The results show the utility of these echo state networks, particularly ones with larger integrated reservoirs, for predicting electrocardiogram waveforms and the adaptability of such models across individuals. The work presented here offers a unique approach for understanding and predicting a patient's waveforms in order to potentially improve alarm generation. We conclude with a brief discussion of future extensions of this research.
United in Prevention–Electrocardiographic Screening for Chronic Obstructive Pulmonary Disease
Mazic, Sanja; Stajic, Zoran; Djelic, Marina; Zlatkovic-Svenda, Mirjana; Putnikovic, Biljana
2013-01-01
CONFLICT OF INTEREST: NONE DECLARED Introduction P-wave abnormalities on the resting electrocardiogram have been associated with cardiovascular or pulmonary disease. So far, “Gothic” P wave and verticalization of the frontal plane axis is related to lung disease, particularly obstructive lung disease. Aim We tested if inverted P wave in AVl as a lone criteria of P wave axis >70° could be screening tool for emphysema. Material and method 1095 routine electrocardiograms (ECGs) were reviewed which yielded 478 (82,1%) ECGs with vertical P-axis in sinus rhythm. Charts were reviewed for the diagnosis of COPD and emphysema based on medical history and pulmonary function tests. Conclusion Electrocardiogram is very effective screening tool not only in cardiovascular field but in chronic obstructive pulmonary disease. The verticality of the P axis is usually immediately apparent, making electrocardiogram rapid screening test for emphysema. PMID:24058253
Automated measurements for individualized heart rate correction of the QT interval.
Mason, Jay W; Moon, Thomas E
2015-04-01
Subject-specific electrocardiographic QT interval correction for heart rate is often used in clinical trials with frequent electrocardiographic recordings. However, in these studies relatively few 10-s, 12-lead electrocardiograms may be available for calculating the individual correction. Highly automated QT and RR measurement tools have made it practical to measure electrocardiographic intervals on large volumes of continuous electrocardiogram data. The purpose of this study was to determine whether an automated method can be used in lieu of a manual method. In 49 subjects who completed all treatments in a four-armed crossover study we compared two methods for derivation of individualized rate-correction coefficients: manual measurement on 10-s electrocardiograms and automated measurement of QT and RR during continuous 24-h electrocardiogram recordings. The four treatments, received by each subject in a latin-square randomization sequence were placebo, moxifloxacin, and two doses of an investigational drug. Analysis of continuous electrocardiogram data yielded a lower standard deviation of QT:RR regression values than the manual method, though the differences were not statistically significant. The within-subject and within-treatment coefficients of variation between the manual and automated methods were not significantly different. Corrected QT values from the two methods had similar rates of true and false positive identification of moxifloxacin's QT prolonging effect. An automated method for individualized rate correction applied to continuous electrocardiogram data could be advantageous in clinical trials, as the automated method is simpler, is based upon a much larger volume of data, yields similar results, and requires no human over-reading of the measurements. © The Author(s) 2015.
Contourograph display system for monitoring electrocardiograms
NASA Technical Reports Server (NTRS)
Golden, D. P., Jr.; Maudlin, D. G.; Wolthuis, R. A.
1970-01-01
Electrocardiogram is displayed as a contourogram on the cathode ray tube of a variable-persistence oscilloscope. Each cycle is stacked below its predecessors giving a three dimensional effect. A major change in the signal is apparent as a change in the contourogram pattern.
Artifactual ECG changes induced by electrocautery in a patient with coronary artery disease.
Naik, B Naveen; Luthra, Ankur; Dwivedi, Ashish; Jafra, Anudeep
Continuous monitoring of 5-lead electrocardiogram is a basic standard of care (included under standard ASA monitor) in the operating room and electrocautery interference is a common phenomenon. Clinical signs, along with monitored waveforms from other simultaneously monitored parameters may provide us clues to differentiate artifacts from true changes on the electrocardiogram. An improved understanding of the artifacts generated by electrocautery and their identifying characteristics is important to avoid misinterpretation, misdiagnosis, and hence mismanagement. This case report highlights the artifacts in electrocardiogram induced by electrocautery. Copyright © 2017 Elsevier Inc. All rights reserved.
Electrocardiogram transmission - The state of the art.
NASA Technical Reports Server (NTRS)
Firstenberg, A.; Huston, S. W.; Olsen, D. E.; Hahn, P. M.
1971-01-01
A comparative analysis of available clinical EKG telemetry systems was conducted. Although present day electrocardiogram diagnosis requires a high degree of measurement accuracy, there exists wide variations in the performance characteristics of the various telemeters marketed today necessitating careful consideration of specifications prior to procurement. The authors have endeavored to provide the physicians with a clear understanding, in terms of the effects on the electrocardiogram, of the factors he must evaluate in order to ensure high fidelity EKG reproduction. A tabulation of comparative parameter values for each unit obtained from manufacturers' specifications and substantiated by standardized performance tests conducted in our laboratory is presented.
A brief review: history to understand fundamentals of electrocardiography
AlGhatrif, Majd; Lindsay, Joseph
2012-01-01
The last decade of the 19th century witnessed the rise of a new era in which physicians used technology along with classical history taking and physical examination for the diagnosis of heart disease. The introduction of chest x-rays and the electrocardiograph (electrocardiogram) provided objective information about the structure and function of the heart. In the first half of the 20th century, a number of innovative individuals set in motion a fascinating sequence of discoveries and inventions that led to the 12-lead electrocardiogram, as we know it now. Electrocardiography, nowadays, is an essential part of the initial evaluation for patients presenting with cardiac complaints. As a first line diagnostic tool, health care providers at different levels of training and expertise frequently find it imperative to interpret electrocardiograms. It is likely that an understanding of the electrical basis of electrocardiograms would reduce the likelihood of error. An understanding of the disorders behind electrocardiographic phenomena could reduce the need for memorizing what may seem to be an endless list of patterns. In this article, we will review the important steps in the evolution of electrocardiogram. As is the case in most human endeavors, an understanding of history enables one to deal effectively with the present. PMID:23882360
A markup language for electrocardiogram data acquisition and analysis (ecgML)
Wang, Haiying; Azuaje, Francisco; Jung, Benjamin; Black, Norman
2003-01-01
Background The storage and distribution of electrocardiogram data is based on different formats. There is a need to promote the development of standards for their exchange and analysis. Such models should be platform-/ system- and application-independent, flexible and open to every member of the scientific community. Methods A minimum set of information for the representation and storage of electrocardiogram signals has been synthesised from existing recommendations. This specification is encoded into an XML-vocabulary. The model may aid in a flexible exchange and analysis of electrocardiogram information. Results Based on advantages of XML technologies, ecgML has the ability to present a system-, application- and format-independent solution for representation and exchange of electrocardiogram data. The distinction between the proposal developed by the U.S Food and Drug Administration and ecgML model is given. A series of tools, which aim to facilitate ecgML-based applications, are presented. Conclusions The models proposed here can facilitate the generation of a data format, which opens ways for better and clearer interpretation by both humans and machines. Its structured and transparent organisation will allow researchers to expand and test its capabilities in different application domains. The specification and programs for this protocol are publicly available. PMID:12735790
Verdurmen, Kim M J; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; Delhaas, Tammo; van Laar, Judith O E H; Oei, S Guid
2016-08-17
The fetal anomaly ultrasound only detects 65 to 81 % of the patients with congenital heart disease, making it the most common structural fetal anomaly of which a significant part is missed during prenatal life. Therefore, we need a reliable non-invasive diagnostic method which improves the predictive value for congenital heart diseases early in pregnancy. Fetal electrocardiography could be this desired diagnostic method. There are multiple technical challenges to overcome in the conduction of the fetal electrocardiogram. In addition, interpretation is difficult due to the organisation of the fetal circulation in utero. We want to establish the normal ranges and values of the fetal electrocardiogram parameters in healthy fetuses of 18 to 24 weeks of gestation. Women with an uneventful singleton pregnancy between 18 and 24 weeks of gestation are asked to participate in this prospective cohort study. A certified and experienced sonographist performs the fetal anomaly scan. Subsequently, a fetal electrocardiogram recording is performed using dedicated signal processing methods. Measurements are performed at two institutes. We will include 300 participants to determine the normal values and 95 % confidence intervals of the fetal electrocardiogram parameters in a healthy fetus. We will evaluate the fetal heart rate, segment intervals, normalised amplitude and the fetal heart axis. Three months postpartum, we will evaluate if a newborn is healthy through a questionnaire. Fetal electrocardiography could be a promising tool in the screening program for congenital heart diseases. The electrocardiogram is a depiction of the intimate relationship between the cardiac nerve conduction pathways and the structural morphology of the fetal heart, and therefore particularly suitable for the detection of secondary effects due to a congenital heart disease (hypotrophy, hypertrophy and conduction interruption).
Yildiz, Mustafa; Aygin, Dilek; Pazarli, Pinar; Sayan, Ayse; Semiz, Olcay; Kahyaoglu, Osman; Yildiz, Banu S; Hasdemir, Hakan; Akin, Ibrahim; Keser, Nurgul; Altinkaynak, Sevin
2011-10-01
The 12-lead electrocardiogram shows a broad range of abnormal patterns in trained athletes. The primary end point of this study was to investigate P wave dispersion, and P wave durations and related factors in different genders applying for registration to the School of Physical Education and Sports. From 2006 to 2009, a total of 2093 students - 1674 boys with a mean age of 19.8 plus or minus 1.9 years and 419 girls with a mean age of 19.1 plus or minus 1.8 years - were included in the study. All 12 leads of the resting electrocardiogram were evaluated for P wave dispersion and electrocardiogram abnormalities. Baseline parameters such as age, body weight, body height, and body mass index, as well as electrocardiogram findings such as P wave maximal duration and P wave dispersion, were significantly higher in boys than in girls. Of all the parameters tested with correlation analysis, only gender (p = 0.03) (r = 0.04), body weight (p < 0.001) (r = 0.07), body height (p = 0.004) (r = 0.06), and body mass index (p = 0.01) (p = 0.05) were correlated with P wave dispersion. The frequencies of all electrocardiogram abnormalities, P wave dispersion, and P wave maximal duration were higher in boys as compared with girls in an unselected student population applying for registration to the School of Physical Education and Sports; in addition, P wave dispersion was correlated with gender, body weight, body height, and body mass index.
Brunetti, Natale D; Ieva, Riccardo; Correale, Michele; Cuculo, Andrea; Santoro, Francesco; Guaricci, Andrea I; De Gennaro, Luisa; Gaglione, Antonio; Di Biase, Matteo
2016-01-01
The Brugada electrocardiogram pattern is characterized by coved-type ST-elevation (>2 mm) in the right precordial leads. We report the case of a 62-year-old man, with bipolar disorder, admitted to the emergency department because of dyspnea and chest discomfort. The patient was on treatment with pregabalin and quetiapine. Unexpectedly, electrocardiogram at admission showed diffuse ST-elevation, more evident in inferior leads, where a Brugada-like pattern was present. The patient underwent coronary angiography with a diagnosis of suspected acute coronary syndrome. Coronary angiography, however, showed mild coronary artery disease not requiring coronary angioplasty. Echocardiography did not reveal left ventricular dysfunction or pericardial effusion. Troponin levels remained normal over serial controls. Eventually, chest radiography showed lung opacities and consolidation suggestive for pneumonia. To the best of our knowledge, this is one of the first cases showing a transient Brugada-like electrocardiogram pattern in inferior leads, probably amplified by the administration of pregabalin and quetiapine.
Left ventricular hypertrophy diagnosed after a stroke: a case report.
Umeojiako, Wilfred Ifeanyi; Kanyal, Ritesh
2018-03-22
Stroke is a recognized clinical course of hypertrophic cardiomyopathy. This interesting case showed notable difference on the electrocardiogram of a patient 4 months prior to suffering a stroke and 10 days after suffering a stroke. The pre-stroke electrocardiogram showed atrial fibrillation with a narrow QRS complex, while the post-stroke electrocardiogram showed marked left ventricular hypertrophy. Left ventricular hypertrophy was diagnosed using the Sokolow-Lyon indices. The development of left ventricular hypertrophy a few days after suffering a stroke has not previously been reported. An 83-year-old white British woman with a background history of permanent atrial fibrillation, hypertension, and previous stroke attended the emergency department with a 2-day history of exertional dyspnea, and chest tightness. On examination, she had bibasal crepitations with a systolic murmur loudest at the apex. In-patient investigations include an electrocardiogram, blood tests, chest X-ray, contrast echocardiogram, coronary angiogram, and cardiovascular magnetic resonance imaging. An electrocardiogram showed atrial fibrillation, with inferolateral T wave inversion, and left ventricular hypertrophy. A chest X-ray showed features consistent with pulmonary edema. A contrast echocardiogram showed marked hypertrophy of the mid to apical left ventricle, appearance consistent with apical hypertrophic cardiomyopathy. Coronary angiography showed eccentric shelf-type plaque with non-flow-limiting stenosis in the left coronary artery main stem. Cardiovascular magnetic resonance imaging reported findings highly suggestive of apical hypertrophic cardiomyopathy. Our patient was treated and discharged on rivaroxaban, bisoprolol, and atorvastatin with a follow-up in the cardiomyopathy outpatient clinic. Electrocardiogram diagnosis of left ventricular hypertrophy led to the diagnosis of apical hypertrophic cardiomyopathy in this patient. Left ventricular hypertrophy was only evident a few days after our patient suffered a stroke. The underlying mechanisms responsible for this remain unclear. Furthermore, differential diagnosis of hypertrophic cardiomyopathy should be considered in people with electrocardiogram criteria for left ventricular hypertrophy. Cardiovascular magnetic resonance imaging is an important diagnostic tool in identifying causes of left ventricular hypertrophy. Family screening should be recommended in patients with new diagnosis of hypertrophic cardiomyopathy.
The Normal Electrocardiogram: Resting 12-Lead and Electrocardiogram Monitoring in the Hospital.
Harris, Patricia R E
2016-09-01
The electrocardiogram (ECG) is a well-established diagnostic tool extensively used in clinical settings. Knowledge of cardiac rhythm and mastery of cardiac waveform interpretation are fundamental for intensive care nurses. Recognition of the normal findings for the 12-lead ECG and understanding the significance of changes from baseline in continuous cardiac monitoring are essential steps toward ensuring safe patient care. This article highlights historical developments in electrocardiography, describes the normal resting 12-lead ECG, and discusses the need for continuous cardiac monitoring. In addition, future directions for the ECG are explored briefly. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Feldman, Charles L.
The utilization of computers in the interpretation of electrocardiograms (EKG's) and vectorcardiograms is the subject of this report. A basic introduction into the operations of the electrocardiograms and vectorcardiograms is provided via an illustrated text. A historical development of the EKG starts with the 1950's with the first attempts to use…
Roy, Abhro Jyoti; Stanely Mainzen Prince, P
2013-10-01
The present study evaluated the preventive effects of p-coumaric acid on cardiac hypertrophy and alterations in electrocardiogram, lipids, and lipoproteins in experimentally induced myocardial infarcted rats. Rats were pretreated with p-coumaric acid (8 mg/kg body weight) daily for a period of 7 days and then injected with isoproterenol (100mg/kg body weight) on 8th and 9th day to induce myocardial infarction. Myocardial infarction induced by isoproterenol was indicated by increased level of cardiac sensitive marker and elevated ST-segments in the electrocardiogram. Also, the levels/concentrations of serum and heart cholesterol, triglycerides and free fatty acids were increased in myocardial infarcted rats. Isoproterenol also increased the levels of serum low density and very low density lipoprotein cholesterol and decreased the levels of high density lipoprotein cholesterol. It also enhanced the activity of liver 3-hydroxy-3 methyl glutaryl-Coenzyme-A reductase. p-Coumaric acid pretreatment revealed preventive effects on all the biochemical parameters and electrocardiogram studied in myocardial infarcted rats. The in vitro study confirmed the free radical scavenging property of p-coumaric acid. Thus, p-coumaric acid prevented cardiac hypertrophy and alterations in lipids, lipoproteins, and electrocardiogram, by virtue of its antihypertrophic, antilipidemic, and free radical scavenging effects in isoproterenol induced myocardial infarcted rats. Copyright © 2013 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0084] Submission of Extended Digital Electrocardiogram Waveform Data; Notice of Public Meeting AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public meeting; request for comments. SUMMARY: The Food and...
Direct reading of electrocardiograms and respiration rates
NASA Technical Reports Server (NTRS)
Wise, J. P.
1969-01-01
Technique for reading heart and respiration rates is more accurate and direct than the previous method. Index of a plastic calibrated card is aligned with a point on the electrocardiogram. Complexes are counted as indicated on the card and heart or respiration rate is read directly from the appropriate scale.
"Virtual" Experiment for Understanding the Electrocardiogram and the Mean Electrical Axis.
ERIC Educational Resources Information Center
Anderson, Jamie; DiCarlo, Stephen E.
2000-01-01
Describes a virtual experiment designed to introduce students to the theory and application of the electrocardiogram (ECG) and the mean electrical axis (MEA). Students are asked to reduce and analyze data, calculate and plot the MEA, and answer questions in the inquiry-based, experimental activity. (Author/WRM)
Extension of FRI for modeling of electrocardiogram signals.
Quick, R Frank; Crochiere, Ronald E; Hong, John H; Hormati, Ali; Baechler, Gilles
2012-01-01
Recent work has developed a modeling method applicable to certain types of signals having a "finite rate of innovation" (FRI). Such signals contain a sparse collection of time- or frequency-limited pulses having a restricted set of allowable pulse shapes. A limitation of past work on FRI is that all of the pulses must have the same shape. Many real signals, including electrocardiograms, consist of pulses with varying widths and asymmetry, and therefore are not well fit by the past FRI methods. We present an extension of FRI allowing pulses having variable pulse width (VPW) and asymmetry. We show example results for electrocardiograms and discuss the possibility of application to signal compression and diagnostics.
[Development of a wearable electrocardiogram monitor with recognition of physical activity scene].
Wang, Zihong; Wu, Baoming; Yin, Jian; Gong, Yushun
2012-10-01
To overcome the problems of current electrocardiogram (ECG) tele-monitoring devices used for daily life, according to information fusion thought and by means of wearable technology, we developed a new type of wearable ECG monitor with the capability of physical activity recognition in this paper. The ECG monitor synchronously detected electrocardiogram signal and body acceleration signal, and recognized the scene information of physical activity, and finally determined the health status of the heart. With the advantages of accuracy for measurement, easy to use, comfort to wear, private feelings and long-term continuous in monitoring, this ECG monitor is quite fit for the heart-health monitoring in daily life.
Effectiveness of electrocardiographic guidance in CVAD tip placement.
Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire
International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.
Stark, M E; Vacek, J L
1987-05-01
The first electrocardiogram obtained on presentation for suspected myocardial infarction was examined for its usefulness in predicting clinical course and facility use. We studied 221 patients consecutively admitted to a nonuniversity hospital coronary care unit. High-risk patients were identified if the electrocardiographic diagnoses included myocardial infarction, ischemia, left ventricular hypertrophy, left bundle-branch block, or paced rhythm. These 63 patients (29% of total) had significantly greater incidences of serious events, need for procedures, and death than low-risk patients whose initial electrocardiograms did not carry the above diagnoses. Patients with a low-risk initial electrocardiogram may not require the facilities of a coronary care unit and perhaps could be safely observed in an intermediate care area. However, many hospitals do not have an intermediate care facility available, and in those that do, daily costs may not be markedly different than for treatment in a coronary care unit. Whether these low-risk patients could be safely treated in general medicine beds, where potential cost savings would be much greater, is unknown.
Isaksen, Jonas; Leber, Remo; Schmid, Ramun; Schmid, Hans-Jakob; Generali, Gianluca; Abächerli, Roger
2017-02-01
The first-order high-pass filter (AC coupling) has previously been shown to affect the ECG for higher cut-off frequencies. We seek to find a systematic deviation in computer measurements of the electrocardiogram when the AC coupling with a 0.05 Hz first-order high-pass filter is used. The standard 12-lead electrocardiogram from 1248 patients and the automated measurements of their DC and AC coupled version were used. We expect a large unipolar QRS-complex to produce a deviation in the opposite direction in the ST-segment. We found a strong correlation between the QRS integral and the offset throughout the ST-segment. The coefficient for J amplitude deviation was found to be -0.277 µV/(µV⋅s). Potential dangerous alterations to the diagnostically important ST-segment were found. Medical professionals and software developers for electrocardiogram interpretation programs should be aware of such high-pass filter effects since they could be misinterpreted as pathophysiology or some pathophysiology could be masked by these effects. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Thanaraj, Palani; Roshini, Mable; Balasubramanian, Parvathavarthini
2016-11-14
The fetal electrocardiogram (FECG) signals are essential to monitor the health condition of the baby. Fetal heart rate (FHR) is commonly used for diagnosing certain abnormalities in the formation of the heart. Usually, non-invasive abdominal electrocardiogram (AbECG) signals are obtained by placing surface electrodes in the abdomen region of the pregnant woman. AbECG signals are often not suitable for the direct analysis of fetal heart activity. Moreover, the strength and magnitude of the FECG signals are low compared to the maternal electrocardiogram (MECG) signals. The MECG signals are often superimposed with the FECG signals that make the monitoring of FECG signals a difficult task. Primary goal of the paper is to separate the fetal electrocardiogram (FECG) signals from the unwanted maternal electrocardiogram (MECG) signals. A multivariate signal processing procedure is proposed here that combines the Multivariate Empirical Mode Decomposition (MEMD) and Independent Component Analysis (ICA). The proposed method is evaluated with clinical abdominal signals taken from three pregnant women (N= 3) recorded during the 38-41 weeks of the gestation period. The number of fetal R-wave detected (NEFQRS), the number of unwanted maternal peaks (NMQRS), the number of undetected fetal R-wave (NUFQRS) and the FHR detection accuracy quantifies the performance of our method. Clinical investigation with three test subjects shows an overall detection accuracy of 92.8%. Comparative analysis with benchmark signal processing method such as ICA suggests the noteworthy performance of our method.
Zeng, Shao-ying; Shi, Ji-jun; Li, Hong; Zhang, Zhi-wei; Li, Yu-fen
2010-08-01
To simplify the methods of transcatheter mapping and ablation in the pediatric patients with left posterior fascicular tachycardia. While in sinus rhythm, the fascicular potential can be mapped at the posterior septal region (1 - 2 cm below inferior margin of orifice of coronary sinus vein), which display a biphasic wave before ventricular wave, and exist equipotential lines between them. When the fascicular potential occurs 20 ms later than the bundle of His' potential, radiofrequency was applied. Before applying radiofrequency, catheter position must be observed using double angle viewing (LAO 45°RAO 30°), and it should be made sure that the catheter is not at His' bundle. If the electrocardiogram displays left posterior fascicular block, the correct region is identified and ablation can continue for 60 s. Electrocardiogram monitoring should continue for 24 - 48 hours after operation, and notice abnormal repolarization after termination of ventricular tachycardia. Aspirin [2 - 3 mg/(kg·d)] was used for 3 months, and antiarrhythmic drug was discontinued. Surface electrocardiogram, chest X-ray and ultrasound cardiography were rechecked 1 d after operation. Follow-up was made at 1 month and 3 months post-discharge. Recheck was made half-yearly or follow-up was done by phone from then on. Fifteen pediatric patients were ablated successfully, and their electrocardiograms all displayed left posterior fascicular block after ablation. None of the patients had recurrences during the 3 to 12 months follow-up period. In one case, the electrocardiogram did not change after applying radiofrequency ablation and the ventricular tachycardia remained; however, on second attempt after remapping, the electrocardiogram did change. The radiofrequency lasted for 90 seconds and ablation was successful. This case had no recurrences at 6 months follow-up. Transcatheter ablation of the fascicular potential in pediatric patients with left posterior fascicular tachycardia can simplify mapping, reduce operative difficulty and produce a distinct endpoint for ablation.
Vandael, Eline; Vandenberk, Bert; Vandenberghe, Joris; Spriet, Isabel; Willems, Rik; Foulon, Veerle
2016-04-01
Many drugs, including haloperidol, are linked with a risk of QTc-prolongation, which can lead to Torsade de Pointes and sudden cardiac death. To investigate the prevalence of concomitant risk factors for QTc-prolongation in patients treated with haloperidol, and the use of safety measures to minimize this risk. University Hospitals of Leuven, Belgium. Methods A retrospective epidemiological study was performed. On 15 consecutive Mondays, all patients with a prescription for haloperidol were included. A risk score for QTc-prolongation, inspired by the pro-QTc score of Haugaa et al., was calculated based on gender, comorbidities, lab results and concomitant QTc-prolonging drugs (each factor counting for one point). Available electrocardiograms before and during the treatment of haloperidol were registered. Management of the risk of QTc-prolongation. Two hundred twenty-two patients were included (59.0 % men, median age 77 years) of whom 26.6 % had a risk score of ≥4 (known to significantly increase the mortality). Overall, 24.3 % received haloperidol in combination with other drugs with a known risk of Torsade de Pointes. Half of the patients had an electrocardiogram in the week before the start of haloperidol; only in one-third a follow-up electrocardiogram during haloperidol treatment was performed. Of the patients with a moderately (n = 41) or severely (n = 14) prolonged QTc-interval before haloperidol, 48.8 % and 42.9 % respectively had a follow-up electrocardiogram. In patients with a risk score ≥4, significantly more electrocardiograms were taken before starting haloperidol (p = 0.020). Although many patients had risk factors for QTc-prolongation (including the use of other QTc-prolonging drugs) or had a prolonged QTc on a baseline electrocardiogram, follow-up safety measures were limited. Persistent efforts should be taken to develop decision support systems to manage this risk.
Reconstruction of electrocardiogram using ionic current models for heart muscles.
Yamanaka, A; Okazaki, K; Urushibara, S; Kawato, M; Suzuki, R
1986-11-01
A digital computer model is presented for the simulation of the electrocardiogram during ventricular activation and repolarization (QRS-T waves). The part of the ventricular septum and the left ventricular free wall of the heart are represented by a two dimensional array of 730 homogeneous functional units. Ionic currents models are used to determine the spatial distribution of the electrical activities of these units at each instant of time during simulated cardiac cycle. In order to reconstruct the electrocardiogram, the model is expanded three-dimensionally with equipotential assumption along the third axis and then the surface potentials are calculated using solid angle method. Our digital computer model can be used to improve the understanding of the relationship between body surface potentials and intracellular electrical events.
ERIC Educational Resources Information Center
Dunlap, Justin C.; Kutschera, Ellynne; Van Ness, Grace R.; Widenhorn, Ralf
2015-01-01
We present a general physics laboratory exercise that centres around the use of the electrocardiogram sensor as an application of circuits and electronic signal filtering. Although these topics are commonly taught in the general physics classroom, many students consider topics such as alternating current as unrelated to their future professions.…
Dispersion durations of P-wave and QT interval in children treated with a ketogenic diet.
Doksöz, Önder; Güzel, Orkide; Yılmaz, Ünsal; Işgüder, Rana; Çeleğen, Kübra; Meşe, Timur
2014-04-01
Limited data are available on the effects of a ketogenic diet on dispersion duration of P-wave and QT-interval measures in children. We searched for the changes in these measures with serial electrocardiograms in patients treated with a ketogenic diet. Twenty-five drug-resistant patients with epilepsy treated with a ketogenic diet were enrolled in this study. Electrocardiography was performed in all patients before the beginning and at the sixth month after implementation of the ketogenic diet. Heart rate, maximum and minimum P-wave duration, P-wave dispersion, and maximum and minimum corrected QT interval and QT dispersion were manually measured from the 12-lead surface electrocardiogram. Minimum and maximum corrected QT and QT dispersion measurements showed nonsignificant increase at month 6 compared with baseline values. Other previously mentioned electrocardiogram parameters also showed no significant changes. A ketogenic diet of 6 months' duration has no significant effect on electrocardiogram parameters in children. Further studies with larger samples and longer duration of follow-up are needed to clarify the effects of ketogenic diet on P-wave dispersion and corrected QT and QT dispersion. Copyright © 2014 Elsevier Inc. All rights reserved.
Myocardial infarction false alarm: initial electrocardiogram and cardiac enzymes.
Gupta, Esha Das; Sakthiswary, Rajalingham
2014-05-01
The objectives of this study were to determine the incidence of a myocardial infarction "false alarm" and evaluate the efficacy of the initial electrocardiogram and cardiac enzymes in diagnosing myocardial infarction in Malaysia. We recruited patients who were admitted with suspected myocardial infarction from June to August 2008. The medical records of these patients were reviewed for the initial electrocardiogram, initial cardiac enzyme levels (creatinine kinase-MB and troponin T), and the final diagnosis upon discharge. The subjects were stratified into 2 groups: true myocardial infarction, and false alarm. 125 patients were enrolled in this study. Following admission and further evaluation, the diagnosis was revised from myocardial infarction to other medical conditions in 48 (38.4%) patients. The sensitivity and specificity of the initial ischemic electrocardiographic changes were 54.5% and 70.8%, respectively. Raised cardiac enzymes had a sensitivity of 44.3% and specificity of 95.8%. A significant proportion of patients in Malaysia are admitted with a false-alarm myocardial infarction. The efficacy of the electrocardiogram in diagnosing myocardial infarction in Malaysia was comparable to the findings of Western studies, but the cardiac enzymes had a much lower sensitivity.
2014-11-01
networks were trained to predict an individual’s electrocardiogram (ECG) and arterial blood pressure ( ABP ) waveform data, which can potentially help...various ESN architectures for prediction tasks, and establishes the benefits of using ESN architecture designs for predicting ECG and ABP waveforms...arterial blood pressure ( ABP ) waveforms immediately prior to the machine generated alarms. When tested, the algorithm suppressed approximately 59.7
Lau, Kelvin C; Frank, David B; Hanna, Brian D; Patel, Akash R
2014-07-15
Electrocardiograms have utility in disease stratification and monitoring in adult pulmonary arterial hypertension (PAH). We examined the electrocardiographic findings that are common in pediatric PAH and assessed for correlation with disease severity and progression. We retrospectively identified patients aged≤18 years followed at a single institution from January 2001 to June 2012 with catheterization-confirmed diagnosis of idiopathic PAH and PAH secondary to pulmonary developmental abnormalities. Patients with an electrocardiography performed within 60 days of catheterization were included. Primary and secondary outcomes are the prevalence of abnormal electrocardiographic findings at the time of catheterization and the association between electrocardiographic and hemodynamic findings and electrocardiographic changes with disease progression on follow-up catheterization, respectively. Of the 100 electrocardiography-catheterization pairs derived from the 46 patients identified, 93% had an electrocardiographic abnormality: 78% had right ventricular hypertrophy (RVH) and 52% had right axis deviation (RAD) for age. In patients with idiopathic PAH, the presence of RVH and RAD correlated with pulmonary vascular resistance and transpulmonary gradient. RAD and RVH on baseline electrocardiogram was associated with an increased risk of disease progression on subsequent catheterization (odds ratio 11.0, 95% confidence interval 1.3 to 96.2, p=0.03) after adjusting for PAH subgroup. The sensitivity, specificity, and positive and negative predictive values of RAD and RVH on baseline electrocardiogram for disease progression were 92%, 48%, 33%, and 95%, respectively. In conclusion, electrocardiographic abnormalities are common in pediatric PAH. RAD and RVH on electrocardiogram were associated with worse hemodynamics, whereas their absence is suggestive of a lack of disease progression. Copyright © 2014 Elsevier Inc. All rights reserved.
Noninvasive Fetal Electrocardiography Part II: Segmented-Beat Modulation Method for Signal Denoising
Agostinelli, Angela; Sbrollini, Agnese; Burattini, Luca; Fioretti, Sandro; Di Nardo, Francesco; Burattini, Laura
2017-01-01
Background: Fetal well-being evaluation may be accomplished by monitoring cardiac activity through fetal electrocardiography. Direct fetal electrocardiography (acquired through scalp electrodes) is the gold standard but its invasiveness limits its clinical applicability. Instead, clinical use of indirect fetal electrocardiography (acquired through abdominal electrodes) is limited by its poor signal quality. Objective: Aim of this study was to evaluate the suitability of the Segmented-Beat Modulation Method to denoise indirect fetal electrocardiograms in order to achieve a signal-quality at least comparable to the direct ones. Method: Direct and indirect recordings, simultaneously acquired from 5 pregnant women during labor, were filtered with the Segmented-Beat Modulation Method and correlated in order to assess their morphological correspondence. Signal-to-noise ratio was used to quantify their quality. Results: Amplitude was higher in direct than indirect fetal electrocardiograms (median:104 µV vs. 22 µV; P=7.66·10-4), whereas noise was comparable (median:70 µV vs. 49 µV, P=0.45). Moreover, fetal electrocardiogram amplitude was significantly higher than affecting noise in direct recording (P=3.17·10-2) and significantly in indirect recording (P=1.90·10-3). Consequently, signal-to-noise ratio was initially higher for direct than indirect recordings (median:3.3 dB vs. -2.3 dB; P=3.90·10-3), but became lower after denoising of indirect ones (median:9.6 dB; P=9.84·10-4). Eventually, direct and indirect recordings were highly correlated (median: ρ=0.78; P<10-208), indicating that the two electrocardiograms were morphologically equivalent. Conclusion: Segmented-Beat Modulation Method is particularly useful for denoising of indirect fetal electrocardiogram and may contribute to the spread of this noninvasive technique in the clinical practice. PMID:28567129
Ha, Le Dung; Elbadawi, Ayman; Froelicher, Victor F
2018-01-01
Numerous methods have been proposed for diagnosing left ventricular hypertrophy using the electrocardiogram. They have limited sensitivity for recognizing pathological hypertrophy, at least in part due to their inability to distinguish pathological from physiological hypertrophy. Our objective is to compare the major electrocardiogram-left ventricular hypertrophy criteria using cardiovascular mortality as a surrogate for pathological hypertrophy. This study was a retrospective analysis of 16,253 veterans < 56 years of age seen at a large Veterans Affairs Medical Center from 1987 to 1999 and followed a median of 17.8 years for cardiovascular mortality. Receiver operating characteristics and Cox hazard survival techniques were applied. Of the 16,253 veterans included in our target population, the mean age was 43 years, 8.6% were female, 33.5% met criteria for electrocardiogram-left ventricular hypertrophy, and there were 744 cardiovascular deaths (annual cardiovascular mortality 0.25%). Receiver operating characteristic analysis demonstrated that the greatest area under the curve (AUC) for classification of cardiovascular death was obtained using the Romhilt-Estes score (0.63; 95% confidence interval, 0.61-0.65). Most of the voltage-only criteria had nondiagnostic area under the curves, with the Cornell being the best at 0.59 (95% confidence interval, 0.57-0.62). When the components of the Romhilt-Estes score were examined using step-wise Wald analysis, the voltage criteria dropped from the model. The Romhilt-Estes score ≥ 4, the Cornell, and the Peguero had the highest association with cardiovascular mortality (adjusted hazard ratios 2.2, 2.0, and 2.1, consecutively). None of the electrocardiogram leads with voltage criteria exhibited sufficient classification power for clinical use. Copyright © 2018 Elsevier Inc. All rights reserved.
Hyperthyroidism with dome-and-dart T wave: A case report: A care-compliant article.
Lai, Ping; Yuan, Jing-Ling; Xue, Jin-Hua; Qiu, Yue-Qun
2017-02-01
Dome-and-dart T waves (or bifid T waves) are a rare phenomenon in the surface electrocardiogram. These wave forms are mainly observed in patients with congenital heart disease such as atrial septal defect and ventricular septal defect. And hyperthyroidism who presented with an electrocardiogram that had dome-and-dart T waves in a precordial lead is never been reported. The patient presented with continuous tachycardia, palpitations, chest tightness, and headache for 4 days, and aggravated for 1 day. Hyperthyroidism. Methimazole. All symptoms were alleviated. Dome-and-dart or bifid T waves have been reported in the conventional 12-lead electrocardiograms in some patients with congenital heart disease. The case illustrated here, to the best of our knowledge, dome-and-dart or bifid T waves may associate with hyperthyroidism patients.
Hyperthyroidism with dome-and-dart T wave: A case report
Lai, Ping; Yuan, Jing-ling; Xue, Jin-hua; Qiu, Yue-qun
2017-01-01
Abstract Rationale: Dome-and-dart T waves (or bifid T waves) are a rare phenomenon in the surface electrocardiogram. These wave forms are mainly observed in patients with congenital heart disease such as atrial septal defect and ventricular septal defect. And hyperthyroidism who presented with an electrocardiogram that had dome-and-dart T waves in a precordial lead is never been reported. Patient concerns: The patient presented with continuous tachycardia, palpitations, chest tightness, and headache for 4 days, and aggravated for 1 day. Diagnoses: Hyperthyroidism. Interventions: Methimazole. Outcomes: All symptoms were alleviated. Lessons: Dome-and-dart or bifid T waves have been reported in the conventional 12-lead electrocardiograms in some patients with congenital heart disease. The case illustrated here, to the best of our knowledge, dome-and-dart or bifid T waves may associate with hyperthyroidism patients. PMID:28178156
2009-06-05
were obtained: (1) blood analysis before, immediately after, and 24 hours after exposure, (2) 12-lead electrocardiogram (ECG) recordings before and...this report focuses on the blood chemistry analysis, ECG evaluation, psychomotor function assessment, and post-exposure interview findings. 15. SUBJECT... Blood Chemistry Characteristics ................ 13 Table 2: Summary of Electrocardiogram Analysis Before and After X-26 TASER® Exposure
Madias, John E
2004-04-01
The author describes his experience with a "saline-filled central venous catheter electrocardiographic lead" for the recording of intracardiac electrocardiograms provides a brief description of the methodology, refers to this modality's clinical usefulness, furnishes 2 examples illustrating the contribution of the method to clinical diagnosis, and outlines his literature search to find the discoverer/originator of the employment of a saline-filled intracardiac catheter as an electrocardiogram recording lead.
Computer-Interpreted Electrocardiograms: Benefits and Limitations.
Schläpfer, Jürg; Wellens, Hein J
2017-08-29
Computerized interpretation of the electrocardiogram (CIE) was introduced to improve the correct interpretation of the electrocardiogram (ECG), facilitating health care decision making and reducing costs. Worldwide, millions of ECGs are recorded annually, with the majority automatically analyzed, followed by an immediate interpretation. Limitations in the diagnostic accuracy of CIE were soon recognized and still persist, despite ongoing improvement in ECG algorithms. Unfortunately, inexperienced physicians ordering the ECG may fail to recognize interpretation mistakes and accept the automated diagnosis without criticism. Clinical mismanagement may result, with the risk of exposing patients to useless investigations or potentially dangerous treatment. Consequently, CIE over-reading and confirmation by an experienced ECG reader are essential and are repeatedly recommended in published reports. Implementation of new ECG knowledge is also important. The current status of automated ECG interpretation is reviewed, with suggestions for improvement. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
An Unusual Case of Alternating Ventricular Morphology on the 12-Lead Electrocardiogram.
Sammon, Maura; Dawood, Alveena; Beaudoin, Scott; Harrigan, Richard A
2017-03-01
One of the principal tasks of an emergency physician is identifying potentially life-threatening conditions in the undifferentiated patient; cardiac dysrhythmia is an example of such a condition. A systematic approach to a patient with atypical dysrhythmia enables proper identification of such-life threatening conditions. We describe a 31-year-old man presenting to the emergency department with an undifferentiated dysrhythmia after naloxone reversal of an opiate overdose. A systematic approach to the electrocardiogram led to the rare diagnosis of Wolff-Parkinson-White (WPW) alternans. We review the differential diagnosis of this dysrhythmia and the initial evaluation of a patient with the WPW pattern present on their electrocardiogram. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be prepared to use a systematic approach to an undifferentiated dysrhythmia to identify potentially life-threatening conditions. Copyright © 2016 Elsevier Inc. All rights reserved.
Fent, Graham; Gosai, Jivendra; Purva, Makani
2016-01-01
Accurate interpretation of the electrocardiogram (ECG) remains an essential skill for medical students and junior doctors. While many techniques for teaching ECG interpretation are described, no single method has been shown to be superior. This randomized control trial is the first to investigate whether teaching ECG interpretation using a computer simulator program or traditional teaching leads to improved scores in a test of ECG interpretation among medical students and postgraduate doctors immediately after and 3months following teaching. Participants' opinions of the program were assessed using a questionnaire. There were no differences in ECG interpretation test scores immediately after or 3months after teaching in the lecture or simulator groups. At present therefore, there is insufficient evidence to suggest that ECG simulator programs are superior to traditional teaching. Copyright © 2016 Elsevier Inc. All rights reserved.
Gliner, Vadim; Behar, Joachim; Yaniv, Yael
2018-05-22
In parallel to the introduction of mobile communication devices with high computational power and internet connectivity, high-quality and low-cost health sensors have also become available. However, although the technology does exist, no clinical mobile system has been developed to monitor the R peaks from electrocardiogram recordings in real time with low false positive and low false negative detection. Implementation of a robust electrocardiogram R peak detector for various arrhythmogenic events has been hampered by the lack of an efficient design that will conserve battery power without reducing algorithm complexity or ease of implementation. Our goals in this paper are (1) to evaluate the suitability of the MATLAB Mobile platform for mHealth apps and whether it can run on any phone system, and (2) to embed in the MATLAB Mobile platform a real-time electrocardiogram R peak detector with low false positive and low false negative detection in the presence of the most frequent arrhythmia, atrial fibrillation. We implemented an innovative R peak detection algorithm that deals with motion artifacts, electrical drift, breathing oscillations, electrical spikes, and environmental noise by low-pass filtering. It also fixes the signal polarity and deals with premature beats by heuristic filtering. The algorithm was trained on the annotated non-atrial fibrillation MIT-BIH Arrhythmia Database and tested on the atrial fibrillation MIT-BIH Arrhythmia Database. Finally, the algorithm was implemented on mobile phones connected to a mobile electrocardiogram device using the MATLAB Mobile platform. Our algorithm precisely detected the R peaks with a sensitivity of 99.7% and positive prediction of 99.4%. These results are superior to some state-of-the-art algorithms. The algorithm performs similarly on atrial fibrillation and non-atrial fibrillation patient data. Using MATLAB Mobile, we ran our algorithm in less than an hour on both the iOS and Android system. Our app can accurately analyze 1 minute of real-time electrocardiogram signals in less than 1 second on a mobile phone. Accurate real-time identification of heart rate on a beat-to-beat basis in the presence of noise and atrial fibrillation events using a mobile phone is feasible. ©Vadim Gliner, Joachim Behar, Yael Yaniv. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 22.05.2018.
Coronary anatomy and the 12-lead electrocardiogram: how to tell who is hurting.
Phillips, R A
1997-12-01
Knowledge of how the coronary arteries, cardiac topography, and the 12-lead electrocardiogram (ECG) link together is imperative if the electrical tracing is to be interpreted correctly. Advanced practice nurses not familiar with the ECG may be intimidated by attempts to identify the disease process of myocardial infarctions. This article reviews coronary anatomy and cardiac topography and then links them to the 12-lead ECG for determining areas of myocardial ischemia, injury, and death.
Zhang, Huan; Song, Donghan; An, Lina
2016-05-01
To study the effect of a real-time tele-transmission system of 12-lead electrocardiogram on door-to-balloon time in athletes with ST-elevation myocardial infarction. A total of 60 athletes with chest pain diagnosed as ST-elevation myocardial infarction (STEMI) from our hospital were randomly divided into group A (n=35) and group B (n=25), the patients in group A transmitted the real-time tele-transmission system of 12-lead electrocardiogram to the chest pain center before arriving in hospital, however, the patients in group B not. The median door-to-balloon time was significant shorter in-group A than group B (38min vs 94 min, p<0.01) and the ratio of door-to-balloon time below 90 min was remarkable higher in-group A (94.2% vs 60%, p<0.01). The rate of catheter laboratory occupied was 5.7% in-group A and 40% in group B respectively (p=0.001). There was no statistically difference in mortality between the two groups (5.7% vs 4%, p>0.05). The median length of stay was significant reduced in-group A (5 days vs 7 days, p<0.01). Real-time tele-transmission system of 12 lead electrocardiogram is beneficial to the pre-hospital diagnosis of STEMI.
Hnatkova, K; Malik, M; Kautzner, J; Gang, Y; Camm, A J
1994-01-01
OBJECTIVE--Normal electrocardiographic recordings were analysed to establish the influence of measurement of different numbers of electrocardiographic leads on the results of different formulas expressing QT dispersion and the effects of adjustment of QT dispersion obtained from a subset of an electrocardiogram to approximate to the true QT dispersion obtained from a complete electrocardiogram. SUBJECTS AND METHODS--Resting 12 lead electrocardiograms of 27 healthy people were investigated. In each lead, the QT interval was measured with a digitising board and QT dispersion was evaluated by three formulas: (A) the difference between the longest and the shortest QT interval among all leads; (B) the difference between the second longest and the second shortest QT interval; (C) SD of QT intervals in different leads. For each formula, the "true" dispersion was assessed from all measurable leads and then different combinations of leads were omitted. The mean relative differences between the QT dispersion with a given number of omitted leads and the "true" QT dispersion (mean relative errors) and the coefficients of variance of the results of QT dispersion obtained when omitting combinations of leads were compared for the different formulas. The procedure was repeated with an adjustment of each formula dividing its results by the square root of the number of measured leads. The same approach was used for the measurement of QT dispersion from the chest leads including a fourth formula (D) the SD of interlead differences weighted according to the distances between leads. For different formulas, the mean relative errors caused by omitting individual electrocardiographic leads were also assessed and the importance of individual leads for correct measurement of QT dispersion was investigated. RESULTS--The study found important differences between different formulas for assessment of QT dispersion with respect to compensation for missing measurements of QT interval. The standard max-min formula (A) performed poorly (mean relative errors of 6.1% to 18.5% for missing one to four leads) but was appropriately adjusted with the factor of 1/square root of n (n = number of measured leads). In a population of healthy people such an adjustment removed the systematic bias introduced by missing leads of the 12 lead electrocardiogram and significantly reduced the mean relative errors caused by the omission of several leads. The unadjusted SD was the optimum formula (C) for the analysis of 12 lead electrocardiograms, and the weighted standard deviation (D) was the optimum for the analysis of six lead chest electrocardiograms. The coefficients of variance of measurements of QT dispersion with different missing leads were very large (about 3 to 7 for one to four missing leads). Independently of the formula for measurement of QT dispersion, omission of different leads produced substantially different relative errors. In 12 lead electrocardiograms the largest relative errors (> 10%) were caused by omitting lead aVL or lead V1. CONCLUSIONS--Because of the large coefficients of variance, the concept of adjusting the QT dispersion for different numbers of electrocardiographic leads used in its assessment is difficult if not impossible to fulfil. Thus it is likely to be more appropriate to assess QT dispersion from standardised constant sets of electrocardiographic leads. PMID:7833200
NASA Astrophysics Data System (ADS)
Yan, Hua-Wen; Huang, Xiao-Lin; Zhao, Ying; Si, Jun-Feng; Liu, Tie-Bing; Liu, Hong-Xing
2014-11-01
A series of experiments are conducted to confirm whether the vectors calculated for an early section of a continuous non-invasive fetal electrocardiogram (fECG) recording can be directly applied to subsequent sections in order to reduce the computation required for real-time monitoring. Our results suggest that it is generally feasible to apply the initial optimal maternal and fetal ECG combination vectors to extract the fECG and maternal ECG in subsequent recorded sections.
Notation system and overlay diagrams for the analysis of paced electrocardiograms.
Bernstein, A D; Parsonnet, V
1983-01-01
With the advent of adaptive dual-chamber pacing, the interaction between the pacemaker and the heart is becoming increasingly complex and the interpretation of paced electrocardiograms more difficult. We have developed a set of notation conventions for use in teaching and rhythm-strip analysis. Easily-drawn symbols delineate successful, unsuccessful, and inhibited pacing and sensing events as well as refractory and blanking periods. Another application is to generate movable transparent overlays after programming a pacemaker, to be used in interpreting subsequent rhythm strips.
Electrocardiograms with pacemakers: accuracy of computer reading.
Guglin, Maya E; Datwani, Neeta
2007-04-01
We analyzed the accuracy with which a computer algorithm reads electrocardiograms (ECGs) with electronic pacemakers (PMs). Electrocardiograms were screened for the presence of electronic pacing spikes. Computer-derived interpretations were compared with cardiologists' readings. Computer-drawn interpretations required revision by cardiologists in 61.3% of cases. In 18.4% of cases, the ECG reading algorithm failed to recognize the presence of a PM. The misinterpretation of paced beats as intrinsic beats led to multiple secondary errors, including myocardial infarctions in varying localization. The most common error in computer reading was the failure to identify an underlying rhythm. This error caused frequent misidentification of the PM type, especially when the presence of normal sinus rhythm was not recognized in a tracing with a DDD PM tracking the atrial activity. The increasing number of pacing devices, and the resulting number of ECGs with pacing spikes, mandates the refining of ECG reading algorithms. Improvement is especially needed in the recognition of the underlying rhythm, pacing spikes, and mode of pacing.
Artifacts and noise removal in electrocardiograms using independent component analysis.
Chawla, M P S; Verma, H K; Kumar, Vinod
2008-09-26
Independent component analysis (ICA) is a novel technique capable of separating independent components from electrocardiogram (ECG) complex signals. The purpose of this analysis is to evaluate the effectiveness of ICA in removing artifacts and noise from ECG recordings. ICA is applied to remove artifacts and noise in ECG segments of either an individual ECG CSE data base file or all files. The reconstructed ECGs are compared with the original ECG signal. For the four special cases discussed, the R-Peak magnitudes of the CSE data base ECG waveforms before and after applying ICA are also found. In the results, it is shown that in most of the cases, the percentage error in reconstruction is very small. The results show that there is a significant improvement in signal quality, i.e. SNR. All the ECG recording cases dealt showed an improved ECG appearance after the use of ICA. This establishes the efficacy of ICA in elimination of noise and artifacts in electrocardiograms.
Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando
2017-01-01
Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.
Wong, Jim K; Lobato, Robert L; Pinesett, Andre; Maxwell, Bryan G; Mora-Mangano, Christina T; Perez, Marco V
2014-12-01
To test the hypothesis that including preoperative electrocardiogram (ECG) characteristics with clinical variables significantly improves the new-onset postoperative atrial fibrillation prediction model. Retrospective analysis. Single-center university hospital. Five hundred twenty-six patients, ≥ 18 years of age, who underwent coronary artery bypass grafting, aortic valve replacement, mitral valve replacement/repair, or a combination of valve surgery and coronary artery bypass grafting requiring cardiopulmonary bypass. Retrospective review of medical records. Baseline characteristics and cardiopulmonary bypass times were collected. Digitally-measured timing and voltages from preoperative electrocardiograms were extracted. Postoperative atrial fibrillation was defined as atrial fibrillation requiring therapeutic intervention. Two hundred eight (39.5%) patients developed postoperative atrial fibrillation. Clinical predictors were age, ejection fraction<55%, history of atrial fibrillation, history of cerebral vascular event, and valvular surgery. Three ECG parameters associated with postoperative atrial fibrillation were observed: Premature atrial contraction, p-wave index, and p-frontal axis. Adding electrocardiogram variables to the prediction model with only clinical predictors significantly improved the area under the receiver operating characteristic curve, from 0.71 to 0.78 (p<0.01). Overall net reclassification improvement was 0.059 (p = 0.09). Among those who developed postoperative atrial fibrillation, the net reclassification improvement was 0.063 (p = 0.03). Several p-wave characteristics are independently associated with postoperative atrial fibrillation. Addition of these parameters improves the postoperative atrial fibrillation prediction model. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
O'Neal, Wesley T; Kamel, Hooman; Kleindorfer, Dawn; Judd, Suzanne E; Howard, George; Howard, Virginia J; Soliman, Elsayed Z
2016-01-01
It is currently unknown if premature atrial contractions (PACs) detected on the routine screening electrocardiogram are associated with an increased risk of ischemic stroke. We examined the association between PACs and ischemic stroke in 22,975 (mean age 64 ± 9.2; 56% women; 40% black) participants from the Reasons for Geographic and Racial Differences in Stroke study. Participants who were free of stroke at baseline were included. PACs were detected from centrally read electrocardiograms at baseline. Cox regression was used to examine the association between PACs and ischemic stroke events through March 31, 2014. PACs were present in 1,687 (7.3%) participants at baseline. In a Cox regression model adjusted for stroke risk factors and potential confounders, PACs were associated with an increased risk of ischemic stroke (hazards ratio (HR) 1.34, 95% CI 1.04-1.74). The relationship was limited to non-lacunar infarcts (HR 1.42, 95% CI 1.08-1.87), and not lacunar strokes (HR 1.01, 95% CI 0.51-2.03). An interaction by sex was detected, with the association between PACs and ischemic stroke being stronger among women (HR 1.82, 95% CI 1.29-2.56) than men (HR 1.03, 95% CI 0.69-1.52; p-interaction = 0.0095). PACs detected on the routine electrocardiogram are associated with an increased risk for non-lacunar ischemic strokes, especially in women. © 2016 S. Karger AG, Basel.
An introduction to the reading of electrocardiograms.
Woodrow, P
This article introduces the basic principles of reading electrocardiograms (ECGs) for nurses who are unfamiliar with reading them. For more experienced practitioners there are a number of useful articles and books (e.g. Hampton, 1992a, b) that will help further their knowledge. The ECG records cardiac electrical activity as a graph; interpretation is illustrated here by sinus rhythm. A single ECG lead (lead II) is used throughout this article. Atrial fibrillation is described to show a contrasting dysrhythmia. Specific nursing care is suggested for patients being monitored or having ECGs taken.
Normally Expected Aberrations in the 8-hour Dynamic EKG
NASA Technical Reports Server (NTRS)
Fleck, R. L.; Arnoldi, L. B.; Townsend, J. C.; Tonesk, X.
1970-01-01
The establishment of norms for interpreting long term dynamic electrocardiograms is attempted by correlating a completely disease symptom and cardiac risk factor free sample with a non-pure sample in the direction of normality on various variables. Out of a population of 362 subjects exposed to dynamic electrocardiogram testing, a discrimination between normals and abnormals in terms of traditional risk factors was observed. The two groups differed significantly on the following variables: cholesterol, smoking, systolic blood pressure, white blood count, fasting blood sugar, uric acid, resting EKG, year of birth, and coronary insufficiency.
Lauer, Michael S; Pothier, Claire E; Magid, David J; Smith, S Scott; Kattan, Michael W
2007-12-18
The exercise treadmill test is recommended for risk stratification among patients with intermediate to high pretest probability of coronary artery disease. Posttest risk stratification is based on the Duke treadmill score, which includes only functional capacity and measures of ischemia. To develop and externally validate a post-treadmill test, multivariable mortality prediction rule for adults with suspected coronary artery disease and normal electrocardiograms. Prospective cohort study conducted from September 1990 to May 2004. Exercise treadmill laboratories in a major medical center (derivation set) and a separate HMO (validation set). 33,268 patients in the derivation set and 5821 in the validation set. All patients had normal electrocardiograms and were referred for evaluation of suspected coronary artery disease. The derivation set patients were followed for a median of 6.2 years. A nomogram-illustrated model was derived on the basis of variables easily obtained in the stress laboratory, including age; sex; history of smoking, hypertension, diabetes, or typical angina; and exercise findings of functional capacity, ST-segment changes, symptoms, heart rate recovery, and frequent ventricular ectopy in recovery. The derivation data set included 1619 deaths. Although both the Duke treadmill score and our nomogram-illustrated model were significantly associated with death (P < 0.001), the nomogram was better at discrimination (concordance index for right-censored data, 0.83 vs. 0.73) and calibration. We reclassified many patients with intermediate- to high-risk Duke treadmill scores as low risk on the basis of the nomogram. The model also predicted 3-year mortality rates well in the validation set: Based on an optimal cut-point for a negative predictive value of 0.97, derivation and validation rates were, respectively, 1.7% and 2.5% below the cut-point and 25% and 29% above the cut-point. Blood test-based measures or left ventricular ejection fraction were not included. The nomogram can be applied only to patients with a normal electrocardiogram. Clinical utility remains to be tested. A simple nomogram based on easily obtained pretest and exercise test variables predicted all-cause mortality in adults with suspected coronary artery disease and normal electrocardiograms.
Wavelet transform analysis of transient signals: the seismogram and the electrocardiogram
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anant, K.S.
1997-06-01
In this dissertation I quantitatively demonstrate how the wavelet transform can be an effective mathematical tool for the analysis of transient signals. The two key signal processing applications of the wavelet transform, namely feature identification and representation (i.e., compression), are shown by solving important problems involving the seismogram and the electrocardiogram. The seismic feature identification problem involved locating in time the P and S phase arrivals. Locating these arrivals accurately (particularly the S phase) has been a constant issue in seismic signal processing. In Chapter 3, I show that the wavelet transform can be used to locate both the Pmore » as well as the S phase using only information from single station three-component seismograms. This is accomplished by using the basis function (wave-let) of the wavelet transform as a matching filter and by processing information across scales of the wavelet domain decomposition. The `pick` time results are quite promising as compared to analyst picks. The representation application involved the compression of the electrocardiogram which is a recording of the electrical activity of the heart. Compression of the electrocardiogram is an important problem in biomedical signal processing due to transmission and storage limitations. In Chapter 4, I develop an electrocardiogram compression method that applies vector quantization to the wavelet transform coefficients. The best compression results were obtained by using orthogonal wavelets, due to their ability to represent a signal efficiently. Throughout this thesis the importance of choosing wavelets based on the problem at hand is stressed. In Chapter 5, I introduce a wavelet design method that uses linear prediction in order to design wavelets that are geared to the signal or feature being analyzed. The use of these designed wavelets in a test feature identification application led to positive results. The methods developed in this thesis; the feature identification methods of Chapter 3, the compression methods of Chapter 4, as well as the wavelet design methods of Chapter 5, are general enough to be easily applied to other transient signals.« less
Grazioli, Gonzalo; Sanz de la Garza, Maria; Vidal, Barbara; Montserrat, Silvia; Sarquella-Brugada, Georgia; Pi, Ramon; Til, Lluis; Gutierrez, Josep; Brugada, Josep; Sitges, Marta
2017-09-01
Introduction Pre-participation screening in athletes attempts to reduce the incidence of sudden death during sports by identifying susceptible individuals. The objective of this study was to evaluate the diagnostic capacity of the different pre-participation screening points in adolescent athletes and the cost effectiveness of the programme. Methods Athletes were studied between 12-18 years old. Pre-participation screening included the American Heart Association questionnaire, electrocardiogram, echocardiogram, and stress test. The cost of test was established by the Catalan public health system. Results Of 1650 athletes included, 57% were men and mean age was 15.09 ± 1.82 years. Positive findings were identified as follows: in American Heart Association questionnaire 5.09% of subjects, in electrocardiogram 3.78%, in echocardiogram 4.96%, and in exercise test 1.75%. Six athletes (0.36%) were disqualified from participation and 10 (0.60%) were referred for interventional treatment. Diagnostic capacity was assessed by the area under the curve for detection of diseases that motivated disqualification for sport practice (American Heart Association questionnaire, 0.55; electrocardiogram, 0.72; echocardiogram, 0.88; stress test, 0.57). The cost for each athlete disqualified from the sport for a disease causing sudden death was €45,578. Conclusion The electrocardiogram and echocardiogram were the most useful studies to detect athletes susceptible to sudden death, and the stress test best diagnosed arrhythmias with specific treatment. In our country, pre-participatory screening was cost effective to detect athletes who might experience sudden death in sports.
Prevalence of Cardiovascular Disorders Among Iranian Elite Athletes.
Salehi, Shahin; Moradi Shahpar, Farhad; Norouzi, Gholamreza; Ghazalian, Farshad; Poursaid Esfehani, Mehrshad; Abedi Yekta, Amir Hosein
2016-06-01
Athletes' health is an important issue and for promoting it, pre-participation examination (PPE) is widely performed by responsible bodies around the world. This study was to determine prevalence of cardiovascular disorders among athletes participating in the Asian games and answering the question whether the electrocardiogram (ECG) is a necessary part of pre-participation examination (PPE) for prevention of sudden cardiac death. All athletes participated at Asian games came to sports medicine federation for a PPE including a comprehensive questionnaire, physical examination and ECG. In this retrospective study all profiles of 338 athletes have been studied as well as their electrocardiograms. Multiple logistic regressions as well as Firth's bias reduction were used with R statistical software and SPSS. For predicting the changes in ECG, receiver operating characteristic (ROC) curve has done. Among 388 athletes, 80 (20.6%) were female and 308 (79.4%) male with mean age of 23.2 + 8 years. Nine athletes (2.3%) were smokers, 28 of them (7.2%) experienced chest pain and discomfort, 45 of them (13.3%) had palpitations and 28 (7.2%) had history of anemia. Study of their electrocardiograms showed that long Q-T interval was not seen for anyone, but evidence of left ventricular hypertrophy was seen in 12 (3.1%), inverted T wave in 6 (1.5%), and right bundle branch block in 45 (13.3%). PPE provides very important information of athletes' health. This study has shown that there was not any significant relation between current examination and electrocardiogram changes but regarding the ECG changes we recommend it as a routine part of PPE.
Noninvasive extraction of fetal electrocardiogram based on Support Vector Machine
NASA Astrophysics Data System (ADS)
Fu, Yumei; Xiang, Shihan; Chen, Tianyi; Zhou, Ping; Huang, Weiyan
2015-10-01
The fetal electrocardiogram (FECG) signal has important clinical value for diagnosing the fetal heart diseases and choosing suitable therapeutics schemes to doctors. So, the noninvasive extraction of FECG from electrocardiogram (ECG) signals becomes a hot research point. A new method, the Support Vector Machine (SVM) is utilized for the extraction of FECG with limited size of data. Firstly, the theory of the SVM and the principle of the extraction based on the SVM are studied. Secondly, the transformation of maternal electrocardiogram (MECG) component in abdominal composite signal is verified to be nonlinear and fitted with the SVM. Then, the SVM is trained, and the training results are compared with the real data to ensure the effect of the training. Meanwhile, the parameters of the SVM are optimized to achieve the best performance so that the learning machine can be utilized to fit the unknown samples. Finally, the FECG is extracted by removing the optimal estimation of MECG component from the abdominal composite signal. In order to evaluate the performance of FECG extraction based on the SVM, the Signal-to-Noise Ratio (SNR) and the visual test are used. The experimental results show that the FECG with good quality can be extracted, its SNR ratio is significantly increased as high as 9.2349 dB and the time cost is significantly decreased as short as 0.802 seconds. Compared with the traditional method, the noninvasive extraction method based on the SVM has a simple realization, the shorter treatment time and the better extraction quality under the same conditions.
Tripolar Laplacian electrocardiogram and moment of activation isochronal mapping.
Besio, W; Chen, T
2007-05-01
The electrocardiogram (ECG) provides useful global temporal assessment of the cardiac activity, but has limited spatial capabilities. The Laplacian electrocardiogram (LECG), an improvement over the ECG, provides high spatiotemporal distributed information about cardiac electrical activation. We designed and developed LECG tripolar concentric ring electrode active sensors based on the finite element algorithm 'nine-point method' (NPM). The active sensors were used in an array of 6 by 12 (72) locations to record bipolar and tripolar LECG from the body surface over the anterolateral chest. Compared to bipolar LECG, tripolar LECG showed significantly higher spatial selectivity which may be helpful in inferring information about cardiac activations detected on the body surface. In this study the moment of activation (MOA), an indicator of a depolarization wave passing below the active sensors, was used to surmise possible timing information of the cardiac electrical activation below the active sensors' recording sites. The MOA on the body surface was used to generate isochronal maps that may some day be used by clinicians in diagnosing arrhythmias and assessing the efficacy of therapies.
Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System
Chou, Willy; Wang, Hsing-Yu; Huang, Yan-Jun; Pan, Jeng-Shyang
2013-01-01
Real-time monitoring of cardiac health is helpful for patients with cardiovascular disease. Many telemedicine systems based on ubiquitous computing and communication techniques have been proposed for monitoring the user's electrocardiogram (ECG) anywhere and anytime. Usually, wet electrodes are used in these telemedicine systems. However, wet electrodes require conduction gels and skin preparation that can be inconvenient and uncomfortable for users. In order to overcome this issue, a new non-contact electrode circuit was proposed and applied in developing a mobile electrocardiogram monitoring system. The proposed non-contact electrode can measure bio-potentials across thin clothing, allowing it to be embedded in a user's normal clothing to monitor ECG in daily life. We attempted to simplify the design of these non-contact electrodes to reduce power consumption while continuing to provide good signal quality. The electrical specifications and the performance of monitoring arrhythmia in clinical settings were also validated to investigate the reliability of the proposed design. Experimental results show that the proposed non-contact electrode provides good signal quality for measuring ECG across thin clothes. PMID:27170853
Niegowski, Maciej; Zivanovic, Miroslav
2016-03-01
We present a novel approach aimed at removing electrocardiogram (ECG) perturbation from single-channel surface electromyogram (EMG) recordings by means of unsupervised learning of wavelet-based intensity images. The general idea is to combine the suitability of certain wavelet decomposition bases which provide sparse electrocardiogram time-frequency representations, with the capacity of non-negative matrix factorization (NMF) for extracting patterns from images. In order to overcome convergence problems which often arise in NMF-related applications, we design a novel robust initialization strategy which ensures proper signal decomposition in a wide range of ECG contamination levels. Moreover, the method can be readily used because no a priori knowledge or parameter adjustment is needed. The proposed method was evaluated on real surface EMG signals against two state-of-the-art unsupervised learning algorithms and a singular spectrum analysis based method. The results, expressed in terms of high-to-low energy ratio, normalized median frequency, spectral power difference and normalized average rectified value, suggest that the proposed method enables better ECG-EMG separation quality than the reference methods. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Applying NISHIJIN historical textile technique for e-Textile.
Kuroda, Tomohiro; Hirano, Kikuo; Sugimura, Kazushige; Adachi, Satoshi; Igarashi, Hidetsugu; Ueshima, Kazuo; Nakamura, Hideo; Nambu, Masayuki; Doi, Takahiro
2013-01-01
The e-Textile is the key technology for continuous ambient health monitoring to increase quality of life of patients with chronic diseases. The authors introduce techniques of Japanese historical textile, NISHIJIN, which illustrate almost any pattern from one continuous yarn within the machine weaving process, which is suitable for mixed flow production. Thus, NISHIJIN is suitable for e-Textile production, which requires rapid prototyping and mass production of very complicated patterns. The authors prototyped and evaluated a few vests to take twelve-lead electrocardiogram. The result tells that the prototypes obtains electrocardiogram, which is good enough for diagnosis.
The asymptomatic teenager with an abnormal electrocardiogram.
Singh, Harinder R
2014-02-01
Use of medications for attention-deficit hyperkinetic disorder and preparticipation sports physical examination has led to an increase in number of electrocardiograms (ECG) performed during adolescence. Interpreting ECGs in children and young adults must take into account the evolutionary changes with age and the benign variants, which are usually not associated with heart disease. It is crucial for primary-care providers to recognize the changes on ECG associated with heart disease and risk of sudden death. In this article, the significance, sensitivity, specificity, and the diagnostic workup of these findings in the asymptomatic teenager are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.
[Synchronous playing and acquiring of heart sounds and electrocardiogram based on labVIEW].
Dan, Chunmei; He, Wei; Zhou, Jing; Que, Xiaosheng
2008-12-01
In this paper is described a comprehensive system, which can acquire heart sounds and electrocardiogram (ECG) in parallel, synchronize the display; and play of heart sound and make auscultation and check phonocardiogram to tie in. The hardware system with C8051F340 as the core acquires the heart sound and ECG synchronously, and then sends them to indicators, respectively. Heart sounds are displayed and played simultaneously by controlling the moment of writing to indicator and sound output device. In clinical testing, heart sounds can be successfully located with ECG and real-time played.
NASA Astrophysics Data System (ADS)
Dunlap, Justin C.; Kutschera, Ellynne; Van Ness, Grace R.; Widenhorn, Ralf
2015-01-01
We present a general physics laboratory exercise that centres around the use of the electrocardiogram sensor as an application of circuits and electronic signal filtering. Although these topics are commonly taught in the general physics classroom, many students consider topics such as alternating current as unrelated to their future professions. This exercise provides the motivation for life science and pre-health majors to learn concepts such as voltage, resistance, alternating and direct current, RLC circuits, as well as signal and noise, in an introductory undergraduate physics lab.
Electrocardiogram and Imaging: An Integrated Approach to Arrhythmogenic Cardiomyopathies.
Savino, Ketty; Bagliani, Giuseppe; Crusco, Federico; Padeletti, Margherita; Lombardi, Massimo
2018-06-01
Cardiovascular imaging has radically changed the management of patients with arrhythmogenic cardiomyopathies. This article focuses on the role of echocardiography and MRI in the diagnosis of these structural diseases. Cardiomyopathies with hypertrophic pattern (hypertrophic cardiomyopathy, restrictive cardiomyopathies, amyloidosis, Anderson-Fabry disease, and sarcoidosis), cardiomyopathies with dilated pattern, inflammatory cardiac diseases, and right ventricular arrhythmogenic cardiomyopathy are analyzed. Finally, anatomic predictors of arrhythmias and sudden cardiac death are discussed. Each paragraph is attended by clinical cases that are discussed on the electrocardiogram, after integrated with the anatomic, functional, and hemodynamic modifications of cardiovascular imaging. Copyright © 2018 Elsevier Inc. All rights reserved.
Chameleons: Electrocardiogram Imitators of ST-Segment Elevation Myocardial Infarction.
Nable, Jose V; Lawner, Benjamin J
2015-08-01
The imperative for timely reperfusion therapy for patients presenting with ST-segment elevation myocardial infarction (STEMI) underscores the need for clinicians to have an understanding of how to distinguish patterns of STEMI from its imitators. These imitating diagnoses may confound an evaluation, potentially delaying necessary therapy. Although numerous diagnoses may mimic STEMI, several morphologic clues may allow the physician to determine if the pattern is concerning for either STEMI or a mimicking diagnosis. Furthermore, obtaining a satisfactory history, comparing previous electrocardiograms, and assessing serial tests may provide valuable clues. Copyright © 2015 Elsevier Inc. All rights reserved.
Use of the Surface Electrocardiogram to Define the Nature of Challenging Arrhythmias.
Singh, David K; Peter, C Thomas
2016-03-01
Despite unprecedented advances in technology, the electrocardiogram (ECG) remains essential to the practice of modern electrophysiology. Since its emergence at the turn of the nineteenth century, the form of the ECG has changed little. What has changed is our ability to understand the complex mechanisms that underlie various arrhythmias. In this article, the authors review several important principles of ECG interpretation by providing illustrative tracings. The authors also highlight several important concepts that be can used in ECG analysis. There are several fundamental principles that should be considered in ECG interpretation. Copyright © 2016 Elsevier Inc. All rights reserved.
Apical hypertrophy associated with rapid T wave inversion on the electrocardiogram.
Yamanari, H; Saito, D; Mikio, K; Nakamura, K; Nanba, T; Morita, H; Mizuo, K; Sato, T; Ohe, T
1995-01-01
A 53-year-old man who had no chest pain and no family history of heart disease demonstrated a rapid T wave change on an electrocardiogram, from a positive T wave to a giant negative T wave, within 1 year. Echocardiography showed no left ventricular hypertrophy before or after the T wave change. Cine-magnetic resonance imaging revealed focal apical hypertrophy after the appearance of the giant negative T wave. Although T wave inversions sometimes develop within a short period in patients with hypertrophic cardiomyopathy, they are rare in a patient without hypertension or chest pain.
Chung, Seungmin; Yi, Joohee
2013-01-01
Electromagnetic interference (EMI) can affect various medical devices. Herein, we report the case of EMI from wireless local area network (WLAN) on an electrocardiogram (ECG) monitoring system. A patient who had a prior myocardial infarction participated in the cardiac rehabilitation program in the sports medicine center of our hospital under the wireless ECG monitoring system. After WLAN was installed, wireless ECG monitoring system failed to show a proper ECG signal. ECG signal was distorted when WLAN was turned on, but it was normalized after turning off the WLAN. PMID:23613696
Katoh, Takao; Kuwamoto, Kana; Kato, Daisuke; Kuroishi, Kentarou
2016-12-01
To assess the effect of 25 or 50 mg mirabegron on cardiovascular end-points and adverse drug reactions in real-world Japanese patients with overactive bladder and cardiovascular disease. Participants had overactive bladder, a history of/coexisting cardiovascular disease and a 12-lead electrocardiogram carried out ≤7 days before initiating 4 weeks of mirabegron treatment. Patients with "serious cardiovascular disease" (class III or IV on the New York Heart Association functional classification and further confirmed by expert analysis) were excluded. Patient demographics, physical characteristics and cardiovascular history were recorded. After 4 weeks, patients underwent another electrocardiogram. Incidence of cardiovascular adverse drug reactions and change from baseline in electrocardiogram parameters (RR, PR, QRS intervals, Fridericia's corrected QT and heart rate) were assessed. Of 316 patients registered, 236 met criteria and had baseline/post-dose electrocardiograms: 61.9% male; 60.2% aged ≥75 years; 93.6% with coexisting cardiovascular disease, notably, arrhythmia (67.8%) and angina pectoris (19.1%). Starting mirabegron daily doses were 25 mg (19.9%) or 50 mg (80.1%). The incidence of cardiovascular adverse drug reactions was 5.51%. After 4 weeks, the mean heart rate increased by 1.24 b.p.m. (statistically significant, but clinically acceptable as per previous trials). No significant changes were observed in PR, QRS or Fridericia's corrected QT. No significant correlations in the total population or age-/sex-segregated subgroups were observed between baseline Fridericia's corrected QT and change at 4 weeks. No correlation for heart rate versus change from baseline heart rate with treatment was observed. Mirabegron was well tolerated in real-world Japanese patients with overactive bladder and coexisting cardiovascular disease. No unexpected cardiovascular safety concerns were observed. © 2016 The Japanese Urological Association.
Blood pulse wave velocity measured by photoacoustic microscopy
NASA Astrophysics Data System (ADS)
Yeh, Chenghung; Hu, Song; Maslov, Konstantin; Wang, Lihong V.
2013-03-01
Blood pulse wave velocity (PWV) is an important indicator for vascular stiffness. In this letter, we present electrocardiogram-synchronized photoacoustic microscopy for in vivo noninvasive quantification of the PWV in the peripheral vessels of mice. Interestingly, strong correlation between blood flow speed and ECG were clearly observed in arteries but not in veins. PWV is measured by the pulse travel time and the distance between two spot of a chose vessel, where simultaneously recorded electrocardiograms served as references. Statistical analysis shows a linear correlation between the PWV and the vessel diameter, which agrees with known physiology. Keywords: photoacoustic microscopy, photoacoustic spectroscopy, bilirubin, scattering medium.
Rejection of the maternal electrocardiogram in the electrohysterogram signal.
Leman, H; Marque, C
2000-08-01
The electrohysterogram (EHG) signal is mainly corrupted by the mother's electrocardiogram (ECG), which remains present despite analog filtering during acquisition. Wavelets are a powerful denoising tool and have already proved their efficiency on the EHG. In this paper, we propose a new method that employs the redundant wavelet packet transform. We first study wavelet packet coefficient histograms and propose an algorithm to automatically detect the histogram mode number. Using a new criterion, we compute a best basis adapted to the denoising. After EHG wavelet packet coefficient thresholding in the selected basis, the inverse transform is applied. The ECG seems to be very efficiently removed.
Myocarditis in athlete and myocardial bridge: An innocent bystander?
Quaranta, Federico; Guerra, Emanuele; Sperandii, Fabio; De Santis, Francesco; Pigozzi, Fabio; Calò, Leonardo; Borrione, Paolo
2015-01-01
Myocarditis is a bacterial or viral inflammatory disease, often unnoticed or misdiagnosed. Athletes with myocarditis must stop practicing their activity since International medical Literature described some cases of sudden death. In the present report, we describe a case of an asymptomatic, apparently healthy, competitive athletes, who was diagnosed a myocarditis and as incidental finding a myocardial bridging. We focused the attention on the importance of anamnesis, electrocardiogram and athletes’ entourage for the diagnosis of such insidious pathologies and we evaluated the follow up, focusing the attention on electrocardiogram changes as well as on restitution ad integrum and prognosis, especially for the athletes. PMID:26015860
The electrocardiogram of athletes Comparison with untrained subjects1
Van Ganse, W.; Versee, L.; Eylenbosch, W.; Vuylsteek, K.
1970-01-01
The resting electrocardiograms of 30 cyclists currently involved in competitive sport were compared with those of an equal number of healthy controls matched for age, height, and weight. The cyclists had significantly lower heart rates, longer PQ,QRS, and QTc intervals, higher T waves in lead II, left axis deviation of the T wave, higher R waves in the right and deeper S waves in the left praecordial leads, and deeper S waves in the right and higher R waves in the left praecordial leads. The possible significance of these findings should be assessed by prolonged prospective studies in athletes and untrained control subjects. PMID:4245411
Using the 12-Lead Electrocardiogram in the Care of Athletic Patients.
Yeo, Tee Joo; Sharma, Sanjay
2016-11-01
This article summarizes the role of the 12-lead electrocardiogram (ECG) for the clinical care of athletes, with particular reference to the influence of age, gender, ethnicity, and type of sport on the appearance of the ECG, and its role in differentiating physiologic exercise-related changes from pathologic conditions implicated in sudden cardiac death (SCD). The article also explores the potential role of the ECG in detecting athletes at risk of SCD. In addition, the article reviews the evolution of ECG interpretation criteria and emphasizes the limitations of the ECG as well as the potential for future research. Copyright © 2016 Elsevier Inc. All rights reserved.
Yang, Meixue; Liu, Bin; Zhao, Miaomiao; Li, Fan; Wang, Guoqing; Zhou, Fengfeng
2013-01-01
Although electrocardiogram (ECG) fluctuates over time and physical activity, some of its intrinsic measurements serve well as biometric features. Considering its constant availability and difficulty in being faked, the ECG signal is becoming a promising factor for biometric authentication. The majority of the currently available algorithms only work well on healthy participants. A novel normalization and interpolation algorithm is proposed to convert an ECG signal into multiple template cycles, which are comparable between any two ECGs, no matter the sampling rates or health status. The overall accuracies reach 100% and 90.11% for healthy participants and cardiovascular disease (CVD) patients, respectively.
Zhao, Miaomiao; Li, Fan; Wang, Guoqing; Zhou, Fengfeng
2013-01-01
Although electrocardiogram (ECG) fluctuates over time and physical activity, some of its intrinsic measurements serve well as biometric features. Considering its constant availability and difficulty in being faked, the ECG signal is becoming a promising factor for biometric authentication. The majority of the currently available algorithms only work well on healthy participants. A novel normalization and interpolation algorithm is proposed to convert an ECG signal into multiple template cycles, which are comparable between any two ECGs, no matter the sampling rates or health status. The overall accuracies reach 100% and 90.11% for healthy participants and cardiovascular disease (CVD) patients, respectively. PMID:23977063
The development of insulated electrocardiogram electrodes
NASA Technical Reports Server (NTRS)
Portnoy, W. M.; David, R. M.
1971-01-01
An integrated system was developed, consisting of an insulated electrode and an impedance transformer, which can be used for the acquisition of electrocardiographic data. The electrode consists of a thin layer of dielectric material deposited onto a silicon substrate. The impedance transformer is an operational amplifier used in the unity gain configuration. Both electrode and impedance transformer are contained in a plastic housing identical to that used with the NASA Apollo-type electrode. The lower cut off frequency of the electrode system is between 0.01 and 1.0 Hz, depending on the dielectric used and its thickness. Clinical quality electrocardiograms were obtained with these electrodes.
Android based self-diagnostic electrocardiogram system for mobile healthcare.
Choo, Kan-Yeep; Ling, Huo-Chong; Lo, Yew-Chiong; Yap, Zuo-Han; Pua, Jun-Sheng; Phan, Raphael C-W; Goh, Vik-Tor
2015-01-01
Cardiovascular diseases are the most common cause of death worldwide and are characterized by arrhythmia (i.e. irregular rhythm of heartbeat). Arrhythmia occasionally happens under certain conditions, such as stress. Therefore, it is difficult to be diagnosed using electrocardiogram (ECG) devices available in hospitals for just a few minutes. Constant diagnosis and monitoring of heartbeat is required to reduce death caused by cardiovascular diseases. Mobile healthcare system has emerged as a potential solution to assist patients in monitoring their own heart condition, especially those who are isolated from the reference hospital. This paper proposes a self-diagnostic electrocardiogram system for mobile healthcare that has the capability to perform a real-time ECG diagnostic. The self-diagnostic capability of a real-time ECG signal is achieved by implementing a detrended fluctuation analysis (DFA) method. The result obtained from DFA is used to display the patient's health condition on a smartphone anytime and anywhere. If the health condition is critical, the system will alert the patient and his medical practitioner for further diagnosis. Experimental results verified the validity of the developed ECG diagnostic application on a smartphone. The proposed system can potentially reduce death caused by cardiovascular diseases by alerting the patient possibly undergoing a heart attack.
Yang, Xianglin; Gu, Jiaojiao; Yan, Hong; Xu, Zhi; Ren, Bing; Yang, Yaming; Yang, Xiaodong; Chen, Qi; Tan, Shaohua
2014-01-01
We used bibliometric analysis methodology in the expanded Science Citation Index to identify highly-cited electrocardiogram (ECG)-related articles with total citations (TC2012) exceeding 100 from the publication year to 2012. Web of Science search tools were used to identify the highly-cited articles. The aspects analyzed for highly cited publications included effect of time on citation analysis, journals and Web of Science categories, number of authors per publication, originating institutions and countries, total citation and total citation per year life cycles of articles (C2012) and research hotspots. Results showed that a total of 467 electrocardiogram-related publications were regarded as the highly-cited publications. TC2012 ranged from 101 to 2879, with 215 as the average number of citations. No highly-cited publications have emerged yet during the first two years of the present 2010 Decade. All 11 countries and institutions originating highly-cited ECG-related publications were developed countries, USA in 9 of them. Four subject categories were identified as hotspots by total citations TC2012 and C2012: atrial fibrillation, long QT syndrome, angina and myocardial infarction, and risk factor analysis and health evaluation. Copyright © 2014 Elsevier Inc. All rights reserved.
Brohet, C R; Richman, H G
1979-06-01
Automated processing of electrocardiograms by the Veterans Administration program was evaluated for both agreement with physician interpretation and interpretative accuracy as assessed with nonelectrocardiographic criteria. One thousand unselected electrocardiograms were analyzed by two reviewer groups, one familiar and the other unfamiliar with the computer program. A significant number of measurement errors involving repolarization changes and left axis deviation occurred; however, interpretative disagreements related to statistical decision were largely language-related. Use of a printout with a more traditional format resulted in agreement with physician interpretation by both reviewer groups in more than 80 percent of cases. Overall sensitivity based on agreement with nonelectrocardiographic criteria was significantly greater with use of the computer program than with use of the conventional criteria utilized by the reviewers. This difference was particularly evident in the subgroup analysis of myocardial infarction and left ventricular hypertrophy. The degree of overdiagnosis of left ventricular hypertrophy and posteroinferior infarction was initially unacceptable, but this difficulty was corrected by adjustment of probabilities. Clinical acceptability of the Veterans Administration program appears to require greater physician education than that needed for other computer programs of electrocardiographic analysis; the flexibility of interpretation by statistical decision offers the potential for better diagnostic accuracy.
Ogunlade, Oluwadare; Ayoka, Abiodun O; Akomolafe, Rufus O; Akinsomisoye, Olumide S; Irinoye, Adedayo I; Ajao, Adewale; Asafa, Muritala A
2015-09-28
Dextrocardia with situs inversus is a rare congenital disease. In patients with this condition, the heart is presented as a mirror image of itself with its apex pointing to the right. The pulmonary and abdominal anatomies are reversed. Dextrocardia with situs inversus occurs at birth but its diagnosis may be in adulthood. This case advances knowledge by graphically describing the unusual electrocardiographic features of dextrocardia in a young adult. We report a case of a 22-year-old Nigerian man of Yoruba ethnicity who presented himself for preadmission medical test. He had a standard 12-lead electrocardiogram which revealed uncommon features: inversion of P waves in leads I, aVL and aVR; dominantly negative QRS waves in leads I, V1 to V6; reverse R wave progression in chest leads; low voltage in V4 to V6; extreme QRS axis; flattened T waves in V4 to V6 and aVR; and inverted T waves in lead I and aVL. An electrocardiogram diagnosis of dextrocardia was made. The differential diagnosis considered was right ventricular hypertrophy. A cardiovascular examination showed pulse rate of 70 beats per minute, blood pressure of 119/62mmHg, visible cardiac impulse at right precordium, apex beat was located at his fifth right intercostal space mid-clavicular line. A chest X-ray (posterior anterior view) including upper abdomen showed dextrocardia; his aortic arch was located on the right. His stomach bubble was located below his right hemidiaphragm. His trachea was slightly deviated to the left. The findings in his lung fields were not remarkable. Abdominopelvic ultrasonography showed that right-sided intra-abdominal organs (liver, gallbladder) were located on the left while left-sided organs (stomach, spleen) were located on the right. His abdominal aorta was on the right while his inferior vena cava was located on the left. A diagnosis of dextrocardia with situs inversus was made ultrasonographically. A properly interpreted electrocardiogram was useful in suspecting the diagnosis of dextrocardia with situs inversus. So, an analysis of a relatively simple and non-invasive diagnostic tool such as an electrocardiogram allows for suspicion of a cardiovascular anomaly in a setting of scarce diagnostic resources.
Kamada, Tomohito; Hayashi, Mutsuharu; Yokoi, Hiroatsu; Fujiwara, Wakaya; Yoshikawa, Daiji; Mukaide, Daisuke; Sugishita, Yoshinori; Yoshinaga, Masataka; Ito, Takehiro; Ozaki, Yukio; Izawa, Hideo
2015-01-01
Takotsubo cardiomyopathy is a disorder characterized by left ventricular apical ballooning with preceding emotional and/or physical stressors. This condition is also an important differential diagnosis of acute coronary syndrome. We herein describe a case of Takotsubo cardiomyopathy, a significant clinical phenomenon, triggered by delayed-onset rhabdomyolysis following the administration of long-term statin treatment, without any preceding stressors or changes in the patient's medical condition, in association with complaints of non-specific muscle-related symptoms. Although an electrocardiogram showed remarkable ST-segment elevation, a careful reading of the electrocardiogram findings revealed the features of Takotsubo cardiomyopathy. Withdrawing the statin therapy improved the patient's cardiac function.
NASA Technical Reports Server (NTRS)
1978-01-01
A method for simultaneous reproduction of images, requiring different amounts of time to reproduce, on a cathode ray tube (CRT) screen is disclosed. Ultrasonic sectional views and electrocardiogram curves are simultaneously reproduced on the CRT screen by producing the images on different areas of a screen with two phosphors having different persistence times and luminous colors, within the times required for the appearance of the images. In front of the area on which is produced the image requiring the shorter time is a color filter which is permeable to the color of the phosphor with the shorter persistence time by which absorbs the color of the other phosphor.
Conaway, Darcy G; Sullivan, Robbie; McCullough, Peter A
2004-01-01
This report examines the impact of resynchronization therapy in a patient with class IV heart failure and a prolonged QRS duration on electrocardiogram. The Kansas City Cardiomyopathy Questionnaire (KCCQ) was used to assess the patient's health status prior to, immediately after, and 2 months after placement of a biventricular pacemaker. B-type natriuretic peptide (BNP) values and electrocardiogram QRS duration were recorded to further document clinical status. Our patient experienced statistically significant improvements in 7 of 10 KCCQ domains after resynchronization. QRS duration narrowed following the procedure and BNP values decreased. Resynchronization therapy improved this patient's symptoms, physical limitations, and self-efficacy when maximal medical therapy failed.
Verdurmen, Kim M J; Warmerdam, Guy J J; Lempersz, Carlijn; Hulsenboom, Alexandra D J; Renckens, Joris; Dieleman, Jeanne P; Vullings, Rik; van Laar, Judith O E H; Oei, S Guid
2018-04-01
Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm labour. Fetal heart rate variability is one of the most important parameters to assess in fetal monitoring, since it is a reliable indicator for fetal distress. To describe the effect of betamethasone on fetal heart rate variability, by applying spectral analysis on non-invasive fetal electrocardiogram recordings. Prospective cohort study. Patients that require betamethasone, with a gestational age from 24 weeks onwards. Fetal heart rate variability parameters on day 1, 2, and 3 after betamethasone administration are compared to a reference measurement. Following 68 inclusions, 12 patients remained with complete series of measurements and sufficient data quality. During day 1, an increase in absolute fetal heart rate variability values was seen. During day 2, a decrease in these values was seen. All trends indicate to return to pre-medication values on day 3. Normalised high- and low-frequency power show little changes during the study period. The changes in fetal heart rate variability following betamethasone administration show the same pattern when calculated by spectral analysis of the fetal electrocardiogram, as when calculated by cardiotocography. Since normalised spectral values show little changes, the influence of autonomic modulation seems minor. Copyright © 2018 Elsevier B.V. All rights reserved.
Prevalence of stroke/cardiovascular risk factors in Hungary
NASA Astrophysics Data System (ADS)
Bodo, M.; Sipos, K.; Thuroczy, G.; Panczel, G.; Ilias, L.; Szonyi, P.; Bodo, M., Jr.; Nebella, T.; Banyasz, A.; Nagy, Z.
2010-04-01
A cross-sectional survey was conducted in Hungary using the Cerberus system which includes: 1) a questionnaire addressing the risk factors for stroke/cardiovascular disease; 2) amplifiers to record the pulse waves of cerebral arteries (rheoencephalography) and peripheral arteries, electrocardiogram and electroencephalogram. Additionally, subjects were measured for carotid stenosis by Doppler ultrasound and 12-lead electrocardiogram; subjects were also screened for blood cholesterol, glucose, and triglyceride levels. Prevalence of the following stroke risk factors was identified: overweight, 63.25%; sclerotic brain arteries (by rheoencephalogram), 54.29%; heart disease, 37.92%; pathologic carotid flow, 34.24%; smoking, 30.55%; high blood cholesterol, 28.70%; hypertension, 27.83%; high triglyceride, 24.35%; abnormality in electrocardiogram, 20%; high glucose, 15.95%; symptoms of transient ischemic attack, 16.07%; alcohol abuse, 6.74%; and diabetes, 4.53%. The study demonstrates a possible model for primary cardiovascular disease/stroke prevention. This method offers a standardizable, cost effective, practical technique for mass screenings by identifying the population at high risk for cardiovascular disturbances, especially cerebrovascular disease (primary prevention). In this model, the rheoencephalogram can detect cerebrovascular arteriosclerosis in the susceptibility/presymptomatic phase, earlier than the Doppler ultrasound technique. The method also provides a model for storing analog physiological signals in a computer-based medical record and is a first step in applying an expert system to stroke prevention.
Pan, Yunping; Zhang, Fangfang; Liu, Ru; Jing, Yan; Shen, Jihong; Li, Zhongjian; Zhu, Huaijie
2014-06-01
To explore the characteristics of RR-Lorenz plot in persistent atrial fibrillation (AF) patients complicating with escape beats and rhythm though ambulatory electrocardiogram. The 24-hour ambulatory electrocardiogram of 291 persistent AF patients in second affiliated hospital of Zhengzhou university from July 2005 to April 2013 were retrospectively analyzed and the RR interval and the QRS wave were measured. Patients were divided into two groups according to the distribution of the RR-Lorenz point [AF without escape beats and rhythm group (Group A, n = 259) and AF with escape beats and rhythm group (Group B, n = 32)]. The characteristics of RR-Lorenz plot between the two groups were compared. (1) Fan-shaped RR-Lorenz plots were evidenced in Group A. (2)In Group B, 30 cases showed fan-shaped with L-shaped and a short dense rods along 45° line. The proportion of escape beats and rhythm was 0.28% (275/98 369) -14.06% (11 263/80 112) . The other 2 cases in group B showed no typical RR-Lorenz plots features. RR-Lorenz plot could help to quickly diagnose persistent AF complicating with escape beats and rhythm according to the typical RR-Lorenz plot characteristics in 24-hour ambulatory electrocardiogram.
Ganière, Vincent; Domenichini, Giulia; Niculescu, Viviana; Cassagneau, Romain; Defaye, Pascal; Burri, Haran
2013-03-01
The prerequisite for cardiac resynchronization therapy (CRT) is ventricular capture, which may be verified by analysis of the surface electrocardiogram (ECG). Few algorithms exist to diagnose loss of ventricular capture. Electrocardiograms from 126 CRT patients were analysed during biventricular (BV), right ventricular (RV), and left ventricular (LV) pacing. An algorithm evaluating QRS narrowing in the limb leads and increasing negativity in lead I to diagnose changes in ventricular capture was devised, prospectively validated, and compared with two existing algorithms. Performance of the algorithm according to ventricular lead position was also assessed. Our algorithm had an accuracy of 88% to correctly identify the changes in ventricular capture (either loss or gain of RV or LV capture). The algorithm had a sensitivity of 94% and a specificity of 96% with an accuracy of 96% for identifying loss of LV capture (the most clinically relevant change), and compared favourably with the existing algorithms. Performance of the algorithms was not significantly affected by RV or LV lead position. A simple two-step algorithm evaluating QRS width in the limb leads and changes in negativity in lead I can accurately diagnose the lead responsible for intermittent loss of ventricular capture in CRT. This simple tool may be of particular use outside the setting of specialized device clinics.
A smart health monitoring chair for nonintrusive measurement of biological signals.
Baek, Hyun Jae; Chung, Gih Sung; Kim, Ko Keun; Park, Kwang Suk
2012-01-01
We developed nonintrusive methods for simultaneous electrocardiogram, photoplethysmogram, and ballistocardiogram measurements that do not require direct contact between instruments and bare skin. These methods were applied to the design of a diagnostic chair for unconstrained heart rate and blood pressure monitoring purposes. Our methods were operationalized through capacitively coupled electrodes installed in the chair back that include high-input impedance amplifiers, and conductive textiles installed in the seat for capacitive driven-right-leg circuit configuration that is capable of recording electrocardiogram information through clothing. Photoplethysmograms were measured through clothing using seat mounted sensors with specially designed amplifier circuits that vary in light intensity according to clothing type. Ballistocardiograms were recorded using a film type transducer material, polyvinylidenefluoride (PVDF), which was installed beneath the seat cover. By simultaneously measuring signals, beat-to-beat heart rates could be monitored even when electrocardiograms were not recorded due to movement artifacts. Beat-to-beat blood pressure was also monitored using unconstrained measurements of pulse arrival time and other physiological parameters, and our experimental results indicated that the estimated blood pressure tended to coincide with actual blood pressure measurements. This study demonstrates the feasibility of our method and device for biological signal monitoring through clothing for unconstrained long-term daily health monitoring that does not require user awareness and is not limited by physical activity.
Electrocardiogram of Clinically Healthy Mithun (Bos frontalis): Variation among Strains
Sanyal, Sagar; Das, Pradip Kumar; Ghosh, Probal Ranjan; Das, Kinsuk; Vupru, Kezha V.; Rajkhowa, Chandan; Mondal, Mohan
2010-01-01
A study was conducted to establish the normal electrocardiogram in four different genetic strains of mithun (Bos frontalis). Electrocardiography, cardiac electrical axis, heart rate, rectal temperature and respiration rate were recorded in a total of 32 adult male mithun of four strains (n = 8 each). It was found that the respiration and heart rates were higher (P < .05) in Manipur than other three strains. Amplitude (P < .05) and duration of P wave and QRS complex differed (P < .01) among the strains. Mizoram strain had the highest amplitude and duration of P wave and QRS complex. On the other hand, higher (P < .05) amplitude and duration of T wave were recorded in Arunachalee and Mizoram strains. The mean electrical axis of QRS complex that were recorded for Arunachalee and Manipur strains were similar to that reported for other bovine species; whereas the electrical axis of QRS for Nagamese and Mizoram strains were more close to feline and caprine species, respectively. In conclusion, electrocardiogram of mithun revealed that the amplitude and duration of P wave, QRS complex and T wave were different among four different genetic strains of mithun and the electrical axis of QRS complex for Nagamese and Mizoram mithuns are dissimilar to bovine species. PMID:20886013
Global electrical heterogeneity as a predictor of cardiovascular mortality in men and women.
Lipponen, Jukka A; Kurl, Sudhir; Laukkanen, Jari A
2018-06-02
The aim of this study was to investigate the contribution of depolarization and repolarization abnormalities, specially abnormalities in global electrical heterogeneity of heart in cardiovascular disease (CVD) and all-cause mortality. Eight hundred and forty men and 911 women, average age of 63 years participated in this study with average follow-up was 14 years. Six electrocardiogram/vector electrocardiogram (ECG/VECG) markers QRS-duration, QTc-interval, QRST-angle, sum of absolute QRST integral (SAI QRST), T-wave roundness, and TV1-amplitude were estimated from VECG measurements. Hazard ratios (HRs) for CVD events (164 deaths) and all-cause mortality (383 deaths) for ECG parameters were calculated. Electrocardiogram or vector electrocardiogram parameter models adjusted for risk clinical factors showed that strongest predictors for CVD mortality were QRST-angle (HR 3.44, 95% confidence interval 2.12-5.36), QTc-interval (2.72, 1.73-4.29), and T-wave roundness (2.09, 1.26-3.46) among men. The strongest ECG/VECG parameters for CVD death were QRST-angle (2.47, 1.37-4.45), SAI QRST (2.37, 1.23-4.6), and QTc-interval (2.15, 1.16-4.01) among female participants. Multivariable adjusted models revealed that strongest independent ECG predictors for CVD death were QRST-angle, QTc-interval, resting heart rate, and T-roundness for men, QRST-angle and SAI QRST for women. QRST-angle, QTc-interval, resting heart rate, and T-roundness were associated with all-cause mortality in male population, although none of the ECG/VECG parameters predicted all-cause mortality among women. Characteristics of global electrical heterogeneity QRST-angle and QTc-interval in men and QRST-angle and SAI QRST among females were strong and independent risk markers for cardiovascular mortality. These parameters provide new additional ECG tools for cardiovascular risk stratification.
Ng, Choon Ta; Chee, Tek Siong; Ling, Lee Fong; Lee, Yian Ping; Ching, Chi Keong; Chua, Terrance S J; Cheok, Christopher; Ong, Hean Yee
2011-06-01
Hypertrophic cardiomyopathy is a leading cause of sudden cardiac death (SCD) in young people in the USA. Pre-participation screening for athletes might reduce the incidence of SCD. In Singapore, military service is compulsory for all young able-bodied male citizens. The Singapore Armed Forces Electrocardiogram and Echocardiogram (SAFE) pre-participation screening protocol based on the Italian programme was introduced. This study evaluates the prevalence of hypertrophic cardiomyopathy (HCM) in a young male South-East Asian population. From October 2008 to May 2009, all male military conscripts underwent pre-participation screening. For all conscripts whose electrocardiogram (ECG) findings fulfilled any of these pre-specified criteria (Group A), direct referral for a transthoracic echocardiogram was mandatory. Conscripts with ECG findings other than pre-specified criteria (e.g. T-wave inversions, repolarization abnormalities) were referred for secondary screening by cardiologists (Group B), which could include echocardiography. Out of 18 476 subjects screened during the study period, 988 (5.3%) subjects were fast tracked for echocardiogram (Group A). Of them, there were three (0.3%) cases with severe abnormalities; there was one case each of HCM, bicuspid aortic valve with significant aortic valve regurgitation, and atrial septal defect with right ventricular systolic dysfunction. The patient with HCM had left axis deviation on ECG. None of the 215 patients who underwent echocardiography following cardiology consult (Group B) had HCM. The prevalence of HCM in our young male population (mean age 19.5, range 16-27) using an ECG-based screening protocol was 0.005%; this appeared lower than published data from other geographical cohorts. Possible explanations include a later age of phenotypic manifestation in our population, limitations of the ECG criteria for screening, or a truly lower prevalence of HCM. More population-based longitudinal studies would be needed to ascertain the true prevalence of HCM in our South-East Asian population.
... CJD: Electroencephalogram (EEG) measures the brain's patterns of electrical activity similar to the way an electrocardiogram (ECG) measures the heart's electrical activity. Brain magnetic resonance imaging (MRI) can detect ...
A Review on the Nonlinear Dynamical System Analysis of Electrocardiogram Signal
Mohapatra, Biswajit
2018-01-01
Electrocardiogram (ECG) signal analysis has received special attention of the researchers in the recent past because of its ability to divulge crucial information about the electrophysiology of the heart and the autonomic nervous system activity in a noninvasive manner. Analysis of the ECG signals has been explored using both linear and nonlinear methods. However, the nonlinear methods of ECG signal analysis are gaining popularity because of their robustness in feature extraction and classification. The current study presents a review of the nonlinear signal analysis methods, namely, reconstructed phase space analysis, Lyapunov exponents, correlation dimension, detrended fluctuation analysis (DFA), recurrence plot, Poincaré plot, approximate entropy, and sample entropy along with their recent applications in the ECG signal analysis. PMID:29854361
NASA Astrophysics Data System (ADS)
Afdala, Adfal; Nuryani, Nuryani; Satrio Nugroho, Anto
2017-01-01
Atrial fibrillation (AF) is a disorder of the heart with fairly high mortality in adults. AF is a common heart arrythmia which is characterized by a missing or irregular contraction of atria. Therefore, finding a method to detect atrial fibrillation is necessary. In this article a system to detect atrial fibrillation has been proposed. Detection system utilized backpropagation artifical neural network. Data input in this method includes power spectrum density of R-peaks interval of electrocardiogram which is selected by wrapping method. This research uses parameter learning rate, momentum, epoch and hidden layer. System produces good performance with accuracy, sensitivity, and specificity of 83.55%, 86.72 % and 81.47 %, respectively.
Junctional tachycardia in a child with non-rheumatic fever streptococcal pharyngitis.
Bansal, Neha; Karpawich, Peter P; Sriram, Chenni S
2017-07-01
Accelerated junctional rhythm has been reported in children in the setting of acute rheumatic fever; however, we describe a hitherto unreported case of isolated junctional tachycardia in a child with streptococcal pharyngitis, not meeting revised Jones criteria for rheumatic fever. A previously healthy, 9-year-old girl presented to the emergency department with complaints of sore throat, low-grade fever, and intermittent chest pain. She was found to have a positive rapid streptococcal antigen test. The initial electrocardiogram showed junctional tachycardia with atrioventricular dissociation in addition to prolonged and aberrant atrioventricular conduction. An echocardiogram revealed normal cardiac anatomy with normal biventricular function. The patient responded to treatment with amoxicillin for streptococcal pharyngitis. The junctional tachycardia and other electrocardiogram abnormalities resolved during follow-up.
Evaluation of agreement between temporal series obtained from electrocardiogram and pulse wave.
NASA Astrophysics Data System (ADS)
Leikan, GM; Rossi, E.; Sanz, MCuadra; Delisle Rodríguez, D.; Mántaras, MC; Nicolet, J.; Zapata, D.; Lapyckyj, I.; Siri, L. Nicola; Perrone, MS
2016-04-01
Heart rate variability allows to study the cardiovascular autonomic nervous system modulation. Usually, this signal is obtained from the electrocardiogram (ECG). A simpler method for recording the pulse wave (PW) is by means of finger photoplethysmography (PPG), which also provides information about the duration of the cardiac cycle. In this study, the correlation and agreement between the time series of the intervals between heartbeats obtained from the ECG with those obtained from the PPG, were studied. Signals analyzed were obtained from young, healthy and resting subjects. For statistical analysis, the Pearson correlation coefficient and the Bland and Altman limits of agreement were used. Results show that the time series constructed from the PW would not replace the ones obtained from ECG.
A Review on the Nonlinear Dynamical System Analysis of Electrocardiogram Signal.
Nayak, Suraj K; Bit, Arindam; Dey, Anilesh; Mohapatra, Biswajit; Pal, Kunal
2018-01-01
Electrocardiogram (ECG) signal analysis has received special attention of the researchers in the recent past because of its ability to divulge crucial information about the electrophysiology of the heart and the autonomic nervous system activity in a noninvasive manner. Analysis of the ECG signals has been explored using both linear and nonlinear methods. However, the nonlinear methods of ECG signal analysis are gaining popularity because of their robustness in feature extraction and classification. The current study presents a review of the nonlinear signal analysis methods, namely, reconstructed phase space analysis, Lyapunov exponents, correlation dimension, detrended fluctuation analysis (DFA), recurrence plot, Poincaré plot, approximate entropy, and sample entropy along with their recent applications in the ECG signal analysis.
... by checking it through the skin with a pulse oximeter Complete blood count (CBC) ECG (electrocardiogram) Looking at ... from the groin ( cardiac catheterization ) Transcutaneous oxygen monitor (pulse oximeter) Echo-Doppler
Heart Rate Assessment Immediately after Birth.
Phillipos, Emily; Solevåg, Anne Lee; Pichler, Gerhard; Aziz, Khalid; van Os, Sylvia; O'Reilly, Megan; Cheung, Po-Yin; Schmölzer, Georg M
2016-01-01
Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. PubMed, EMBASE and Google Scholar were systematically searched using the following terms: 'infant', 'heart rate', 'monitoring', 'delivery room', 'resuscitation', 'stethoscope', 'auscultation', 'palpation', 'pulse oximetry', 'electrocardiogram', 'Doppler ultrasound', 'photoplethysmography' and 'wearable sensors'. Eighteen studies were identified that described various methods of heart rate assessment in newborn infants immediately after birth. Studies examining auscultation, palpation, pulse oximetry, electrocardiography and Doppler ultrasound as ways to measure heart rate were included. Heart rate measurements by pulse oximetry are superior to auscultation and palpation, but there is contradictory evidence about its accuracy depending on whether the sensor is connected to the infant or the oximeter first. Several studies indicate that electrocardiogram provides a reliable heart rate faster than pulse oximetry. Doppler ultrasound shows potential for clinical use, however future evidence is needed to support this conclusion. Heart rate assessment is important and there are many measurement methods. The accuracy of routinely applied methods varies, with palpation and auscultation being the least accurate and electrocardiogram being the most accurate. More research is needed on Doppler ultrasound before its clinical use. © 2015 S. Karger AG, Basel.
Kenttä, Tuomas; Porthan, Kimmo; Tikkanen, Jani T; Väänänen, Heikki; Oikarinen, Lasse; Viitasalo, Matti; Karanko, Hannu; Laaksonen, Maarit; Huikuri, Heikki V
2015-07-01
Early repolarization (ER) is defined as an elevation of the QRS-ST junction in at least two inferior or lateral leads of the standard 12-lead electrocardiogram (ECG). Our purpose was to create an algorithm for the automated detection and classification of ER. A total of 6,047 electrocardiograms were manually graded for ER by two experienced readers. The automated detection of ER was based on quantification of the characteristic slurring or notching in ER-positive leads. The ER detection algorithm was tested and its results were compared with manual grading, which served as the reference. Readers graded 183 ECGs (3.0%) as ER positive, of which the algorithm detected 176 recordings, resulting in sensitivity of 96.2%. Of the 5,864 ER-negative recordings, the algorithm classified 5,281 as negative, resulting in 90.1% specificity. Positive and negative predictive values for the algorithm were 23.2% and 99.9%, respectively, and its accuracy was 90.2%. Inferior ER was correctly detected in 84.6% and lateral ER in 98.6% of the cases. As the automatic algorithm has high sensitivity, it could be used as a prescreening tool for ER; only the electrocardiograms graded positive by the algorithm would be reviewed manually. This would reduce the need for manual labor by 90%. © 2014 Wiley Periodicals, Inc.
Rodriguez-Fernandez, Rodrigo; Infante, Oscar; Perez-Grovas, Héctor; Hernandez, Erika; Ruiz-Palacios, Patricia; Franco, Martha; Lerma, Claudia
2012-06-01
This study evaluated the usefulness of the three-dimensional representation of electrocardiogram traces (3DECG) to reveal acute and gradual changes during a full session of hemodiafiltration (HDF) in end-stage renal disease (ESRD) patients. Fifteen ESRD patients were included (six men, nine women, age 46 ± 19 years old). Serum electrolytes, blood pressure, heart rate, and blood urea nitrogen (BUN) were measured before and after HDF. Continuous electrocardiograms (ECGs) obtained by Holter monitoring during HDF were used to produce the 3DECG. Several major disturbances were identified by 3DECG images: increase in QRS amplitude (47%), decrease in T-wave amplitude (33%), increase in heart rate (33%), and occurrence of arrhythmia (53%). Different arrhythmia types were often concurrent and included isolated supraventricular premature beats (N = 5), atrial fibrillation or atrial bigeminy (N = 2), and isolated premature ventricular beats (N = 6). Patients with decrease in T-wave amplitude had higher potassium and BUN (both before HDF and total removal) than those without decrease in T-wave amplitude (P < 0.05). Concurrent acute and gradual ECG changes during HDF are identified by the 3DECG, which could be useful as a preventive and prognostic method. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Left Ventricular Hypertrophy and Cognitive Decline in Old Age.
Mahinrad, Simin; Vriend, Annelotte E; Jukema, J Wouter; van Heemst, Diana; Sattar, Naveed; Blauw, Gerard Jan; Macfarlane, Peter W; Clark, Elaine N; de Craen, Anton J M; Sabayan, Behnam
2017-01-01
Patients with advanced heart failure run a greater risk of dementia. Whether early cardiac structural changes also associate with cognitive decline is yet to be determined. We tested whether left ventricular hypertrophy (LVH) derived from electrocardiogram associates with cognitive decline in older subjects at risk of cardiovascular disease. We included 4,233 participants (mean age 75.2 years, 47.8% male) from PROSPER (PROspective Study of Pravastatin in the Elderly at Risk). LVH was assessed from baseline electrocardiograms by measuring the Sokolow-Lyon index. Higher levels of Sokolow-Lyon index indicate higher degrees of LVH. Cognitive domains involving selective attention, processing speed, and immediate and delayed memory were measured at baseline and repeated during a mean follow-up of 3.2 years. At baseline, LVH was not associated with worse cognitive function. During follow-up, participants with higher levels of LVH had a steeper decline in cognitive function including in selective attention (p = 0.009), processing speed (p = 0.010), immediate memory (p < 0.001), and delayed memory (p = 0.002). These associations were independent of cardiovascular risk factors, co-morbidities, and medications. LVH assessed by electrocardiogram associates with steeper decline in cognitive function of older subjects independent of cardiovascular risk factors and co-morbidities. This study provides further evidence on the link between subclinical cardiac structural changes and cognitive decline in older subjects.
... help walking when you have a loss of balance during a vertigo attack. Avoid bright lights, TV, ... include: Blood pressure reading Electrocardiogram ( ECG ) Hearing tests Balance testing ( ENG ) Magnetic Resonance Imaging (MRI) Your provider ...
... history of heart disease in the family Normal Results Normal test results include: Heart rate: 60 to ... minute Heart rhythm: Consistent and even What Abnormal Results Mean Abnormal ECG results may be a sign ...
... tests Chest x-ray EKG (electrocardiogram, or heart tracing) Fluids through a vein (IV) Laxative Naloxone, a ... Toxicology Data Network. Morphine. Toxnet.nlm.nih.gov Web site. toxnet.nlm.nih.gov/cgi-bin/sis/ ...
NASA Technical Reports Server (NTRS)
Frost, J. D., Jr.
1972-01-01
Newly designed electrode is prefilled, disposable, electrolyte-saturated spong. New design permits longe periods of storage without deterioration, and readiness in matter of seconds. Electrodes supply signals for electroencephalogram, electro-oculogram, and electrocardiogram.
[Syncope: electrocardiogram and autonomic function tests].
Uribe, William; Baranchuk, Adrián; Botero, Federico
2016-12-23
Syncope represents one of the most frequent reasons for consultation in the emergency department. A proper identification will allow a precise etiologic approach and the optimization of delivery of health resources. Once knowing the classification of syncope; it is the clinical interrogatory what enables to discriminate which of these patients present with a neurogenic mediated syncope or a cardiac mediated syncope. The use of diagnostic methods such as the tilt test, will clarify what type of neurally mediated syncope predominates in the patient. The electrocardiogram is the cornerstone in the identification of those patients who had a true episode of self-limited or aborted sudden death as the first manifestation of their syncope, a fact which provides prognostic and therapeutic information that will impact the morbidity and mortality.
A micropower electrocardiogram amplifier.
Fay, L; Misra, V; Sarpeshkar, R
2009-10-01
We introduce an electrocardiogram (EKG) preamplifier with a power consumption of 2.8 muW, 8.1 muVrms input-referred noise, and a common-mode rejection ratio of 90 dB. Compared to previously reported work, this amplifier represents a significant reduction in power with little compromise in signal quality. The improvement in performance may be attributed to many optimizations throughout the design including the use of subthreshold transistor operation to improve noise efficiency, gain-setting capacitors versus resistors, half-rail operation wherever possible, optimal power allocations among amplifier blocks, and the sizing of devices to improve matching and reduce noise. We envision that the micropower amplifier can be used as part of a wireless EKG monitoring system powered by rectified radio-frequency energy or other forms of energy harvesting like body vibration and body heat.
[Study for portable dynamic ECG monitor and recorder].
Yang, Pengcheng; Li, Yongqin; Chen, Bihua
2012-09-01
This Paper presents a portable dynamic ECG monitor system based on MSP430F149 microcontroller. The electrocardiogram detecting system consists of ECG detecting circuit, man-machine interaction module, MSP430F149 and upper computer software. The ECG detecting circuit including a preamplifier, second-order Butterworth low-pass filter, high-pass filter, and 50Hz trap circuit to detects electrocardiogram and depresses various kinds of interference effectively. A microcontroller is used to collect three channel analog signals which can be displayed on TFT LCD. A SD card is used to record real-time data continuously and implement the FTA16 file system. In the end, a host computer system interface is also designed to analyze the ECG signal and the analysis results can provide diagnosis references to clinical doctors.
[The electrocardiogram in the paediatric age group].
Sanches, M; Coelho, A; Oliveira, E; Lopes, A
2014-09-01
A properly interpreted electrocardiogram (ECG) provides important information and is an inexpensive and easy test to perform. It continues to be the method of choice for the diagnosis of arrhythmias. Although the principles of cardiac electrophysiology are the same, there are anatomical and physiological age-dependent changes which produce specific alterations in the paediatric ECG, and which may be misinterpreted as pathological. The intention of this article is to address in a systematic way the most relevant aspects of the paediatric ECG, to propose a possible reading scheme of the ECG and to review the electrocardiograph tracings most frequently found in the paediatric age group. Copyright © 2013 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.
Bluetooth telemetry system for a wearable electrocardiogram
NASA Astrophysics Data System (ADS)
Green, Ryan B.
The rise of wireless networks has led to a new market in medicine: remote patient monitoring. Practitioners now desire to monitor the health conditions of their patients after hospital release. With the large number of cardiac related deaths and this new demand in medicine being the motivation, this study developed a BluetoothRTM telemetry system for a wearable Electrocardiogram. This study also developed a compression t-shirt to hold the ECG and telemetry system. This device communicates the ECG signal of a patient to an Android device within the ISM frequency bands (2.4-2.48 GHz) where the data is displayed and stored in real time. This study is a stepping stone toward more portable heart monitoring that can communicate with the doctor in real time from remote locations.
Spectral of electrocardiographic RR intervals to indicate atrial fibrillation
NASA Astrophysics Data System (ADS)
Nuryani, Nuryani; Satrio Nugroho, Anto
2017-11-01
Atrial fibrillation is a serious heart diseases, which is associated on the risk of death, and thus an early detection of atrial fibrillation is necessary. We have investigated spectral pattern of electrocardiogram in relation to atrial fibrillation. The utilized feature of electrocardiogram is RR interval. RR interval is the time interval between a two-consecutive R peaks. A series of RR intervals in a time segment is converted to a signal with a frequency domain. The frequency components are investigated to find the components which significantly associate to atrial fibrillation. A segment is defined as atrial fibrillation or normal segments by considering a defined number of atrial fibrillation RR in the segment. Using clinical data of 23 patients with atrial fibrillation, we find that the frequency components could be used to indicate atrial fibrillation.
Pit-a-Pat: A Smart Electrocardiogram System for Detecting Arrhythmia.
Park, Juyoung; Lee, Kuyeon; Kang, Kyungtae
2015-10-01
Electrocardiogram (ECG) telemonitoring is one of the most promising applications of medical telemetry. However, previous approaches to ECG telemonitoring have largely relied on public databases of ECG results. In this article we propose a smart ECG system called Pit-a-Pat, which extracts features from ECG signals and detects arrhythmia. It is designed to run on an Android™ (Google, Mountain View, CA) device, without requiring modifications to other software. We implemented the Pit-a-Pat system using a commercial ECG device, and the experimental results demonstrate the effectiveness and accuracy of Pit-a-Pat for monitoring the ECG signal and analyzing the cardiac activity of a mobile patient. The proposed system allows monitoring of cardiac activity with automatic analysis, thereby providing a convenient, inexpensive, and ubiquitous adjunct to personal healthcare.
Improvement of electrocardiogram by empirical wavelet transform
NASA Astrophysics Data System (ADS)
Chanchang, Vikanda; Kumchaiseemak, Nakorn; Sutthiopad, Malee; Luengviriya, Chaiya
2017-09-01
Electrocardiogram (ECG) is a crucial tool in the detection of cardiac arrhythmia. It is also often used in a routine physical exam, especially, for elderly people. This graphical representation of electrical activity of heart is obtained by a measurement of voltage at the skin; therefore, the signal is always contaminated by noise from various sources. For a proper interpretation, the quality of the ECG should be improved by a noise reduction. In this article, we present a study of a noise filtration in the ECG by using an empirical wavelet transform (EWT). Unlike the traditional wavelet method, EWT is adaptive since the frequency spectrum of the ECG is taken into account in the construction of the wavelet basis. We show that the signal-to-noise ratio increases after the noise filtration for different noise artefacts.
Adaptive noise canceling of electrocardiogram artifacts in single channel electroencephalogram.
Cho, Sung Pil; Song, Mi Hye; Park, Young Cheol; Choi, Ho Seon; Lee, Kyoung Joung
2007-01-01
A new method for estimating and eliminating electrocardiogram (ECG) artifacts from single channel scalp electroencephalogram (EEG) is proposed. The proposed method consists of emphasis of QRS complex from EEG using least squares acceleration (LSA) filter, generation of synchronized pulse with R-peak and ECG artifacts estimation and elimination using adaptive filter. The performance of the proposed method was evaluated using simulated and real EEG recordings, we found that the ECG artifacts were successfully estimated and eliminated in comparison with the conventional multi-channel techniques, which are independent component analysis (ICA) and ensemble average (EA) method. From this we can conclude that the proposed method is useful for the detecting and eliminating the ECG artifacts from single channel EEG and simple to use for ambulatory/portable EEG monitoring system.
... tests Chest x-ray CT (computerized tomography, or advanced imaging) scan EKG (electrocardiogram, or heart tracing) Fluids ... Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; ...
... Iodine is also used during the production of methamphetamine. Note: This list may not be all inclusive. ... breathing machine (ventilator) Blood and urine tests Chest x-ray EKG (electrocardiogram, or heart tracing) Fluids through a ...
... large tunnel-shaped scanner. Electrodes for an electrocardiogram ( ECG ) will be placed on your chest. The PET ... often used when other tests, such as echocardiogram (ECG) and cardiac stress tests do not provide enough ...
Play the Electrocardiogram Game
... Medicine Prize Literature Prize Peace Prize Prize in Economic Sciences Quick Facts Nomination Nomination Physics Prize Chemistry ... Medicine Prize Literature Prize Peace Prize Prize in Economic Sciences Nomination Archive Ceremonies Ceremonies Ceremony Archive Nobel ...
... help the delivery team plan treatment. A screening pulse oximeter test usually is done on all newborns right ... and help plan treatment. The tests may include: pulse oximeter monitoring a chest X-ray electrocardiogram (also called ...
... tests Chest x-ray CT (computerized tomography, or advanced imaging) scan EKG (electrocardiogram, or heart tracing) Fluids ... Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; ...
21 CFR 870.5310 - Automated external defibrillator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart. An AED analyzes the patient's electrocardiogram, interprets the...
21 CFR 870.5310 - Automated external defibrillator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart. An AED analyzes the patient's electrocardiogram, interprets the...
21 CFR 870.5310 - Automated external defibrillator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart. An AED analyzes the patient's electrocardiogram, interprets the...
21 CFR 870.5310 - Automated external defibrillator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart. An AED analyzes the patient's electrocardiogram, interprets the...
21 CFR 870.5310 - Automated external defibrillator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart. An AED analyzes the patient's electrocardiogram, interprets the...
... found in: Household cleaners Metal finishing Swimming pool pH additives Note: This list may not be all ... burns in the esophagus (food pipe) and the stomach (endoscopy) Chest x-ray EKG (electrocardiogram, or heart ...
Fabris, Enrico; van 't Hof, Arnoud; Hamm, Christian W; Lapostolle, Frédéric; Lassen, Jens F; Goodman, Shaun G; Ten Berg, Jurriën M; Bolognese, Leonardo; Cequier, Angel; Chettibi, Mohamed; Hammett, Christopher J; Huber, Kurt; Janzon, Magnus; Merkely, Béla; Storey, Robert F; Zeymer, Uwe; Cantor, Warren J; Tsatsaris, Anne; Kerneis, Mathieu; Diallo, Abdourahmane; Vicaut, Eric; Montalescot, Gilles
2017-08-01
In the ATLANTIC (Administration of Ticagrelor in the catheterization laboratory or in the Ambulance for New ST elevation myocardial Infarction to open the Coronary artery) trial the early use of aspirin, anticoagulation, and ticagrelor coupled with very short medical contact-to-balloon times represent good indicators of optimal treatment of ST-elevation myocardial infarction and an ideal setting to explore which factors may influence coronary reperfusion beyond a well-established pre-hospital system. This study sought to evaluate predictors of complete ST-segment resolution after percutaneous coronary intervention in ST-elevation myocardial infarction patients enrolled in the ATLANTIC trial. ST-segment analysis was performed on electrocardiograms recorded at the time of inclusion (pre-hospital electrocardiogram), and one hour after percutaneous coronary intervention (post-percutaneous coronary intervention electrocardiogram) by an independent core laboratory. Complete ST-segment resolution was defined as ≥70% ST-segment resolution. Complete ST-segment resolution occurred post-percutaneous coronary intervention in 54.9% ( n=800/1456) of patients and predicted lower 30-day composite major adverse cardiovascular and cerebrovascular events (odds ratio 0.35, 95% confidence interval 0.19-0.65; p<0.01), definite stent thrombosis (odds ratio 0.18, 95% confidence interval 0.02-0.88; p=0.03), and total mortality (odds ratio 0.43, 95% confidence interval 0.19-0.97; p=0.04). In multivariate analysis, independent negative predictors of complete ST-segment resolution were the time from symptoms to pre-hospital electrocardiogram (odds ratio 0.91, 95% confidence interval 0.85-0.98; p<0.01) and diabetes mellitus (odds ratio 0.6, 95% confidence interval 0.44-0.83; p<0.01); pre-hospital ticagrelor treatment showed a favorable trend for complete ST-segment resolution (odds ratio 1.22, 95% confidence interval 0.99-1.51; p=0.06). This study confirmed that post-percutaneous coronary intervention complete ST-segment resolution is a valid surrogate marker for cardiovascular clinical outcomes. In the current era of ST-elevation myocardial infarction reperfusion, patients' delay and diabetes mellitus are independent predictors of poor reperfusion and need specific attention in the future.
... disease affects your heart's muscle, blood vessels, and electrical system and is the leading cause of death ... An electrocardiogram (EKG or ECG) measures your heart's electrical activity by placing small electrodes on your chest, ...
Atrial Fibrillation in Children
... of the following tests: Electrocardiogram (also called an EKG or ECG) — this is a noninvasive test used ... About Arrhythmia Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...
Diabetic hyperglycemic hyperosmolar syndrome
... glucose Evaluation for possible causes may include: Blood cultures Chest x-ray Electrocardiogram (ECG) Urinalysis Treatment At the start of treatment, the goal is to correct the water loss. This will improve the blood pressure, urine output, ...
Heart Health Tests for Diabetes Patients
... or fluids in the body. They include: Electrocardiogram ("EKG" or "ECG") This test measures the electrical activity ... Tools & Resources Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...
ECG Electrocardiogram (For Parents)
... presented in a standard sequence. Now the ECG tracings are stored as computer files that can be ... of Use Notice of Nondiscrimination Visit the Nemours Web site. Note: All information on KidsHealth® is for ...
Problems in Recording the Electrocardiogram.
ERIC Educational Resources Information Center
Webster, John G.
The unwanted signals that arise in electrocardiography are discussed. A technical background of electrocardiography is given, along with teaching techniques that educate students of medical instrumentation to solve the problems caused by these signals. (MJH)
Cardiac Computed Tomography (Multidetector CT, or MDCT)
... other tests, such as chest X-rays , electrocardiograms (ECG) , echocardiograms (echocardiography) , or stress tests , don’t give ... be attached to your chest to monitor your ECG. The ECG is also needed to help the ...
Watanabe, T; Aviado, D M
1975-01-01
Experimental induction of pulmonary emphysema caused an increase in sensitivity of the rat to toxicity from inhalation of propellants. The emphysematous rat showed an exaggerated reduction in pulmonary compliance in response to inhalation of trichlorofluoromethane (FC 11). In emphysematous and non emphysematous rats without anesthesia the inhalation of FC 11 caused tachycardia, arrhythmias and other abnormalities in the electrocardiogram. The tachycardiac response was eliminated by induction of barbiturate anesthesia, which increased the sensitivity of the heart to occurrence of abnormalities in the electrocardiogram in response to inhalation of FC 11 as well as of dichlorodifluoromethane (FC 12) and difluoroethane (FC 152a). The acceleration in heart rate in response to inhalation of FC 11, hypoxia or hypercapnea was prevented by prior treatment with a beta-blocking drug.
Soliman, Elsayed Z
2008-01-01
The similarity between and the number of limb lead cables play an important role in the frequency of incorrect connection of limb electrodes. Hence, a modified electrocardiogram (ECG) acquisition procedure is proposed in this brief communication, whereby the left-leg (LL) and right-leg (RL) electrode cables are combined into 1 cable, referred to as combined LL/RL cable. The electrode wires in the combined LL/RL cable are connected to 2 electrodes placed on both sides of the LL. The combined LL/RL cable is unique enough (being thicker) not to be mistaken with the upper limb electrode cables. The proposed modification will not in any way influence the ECG waveforms or amplitudes, and it can be expected to substantially reduce incorrect limb electrode placements.
Zhou, Yu; Ren, Jie
2011-04-01
We put forward a new concept of software oversampling mapping system for electrocardiogram (ECG) to assist the research of the ECG inverse problem to improve the generality of mapping system and the quality of mapping signals. We then developed a conceptual system based on the traditional ECG detecting circuit, Labview and DAQ card produced by National Instruments, and at the same time combined the newly-developed oversampling method into the system. The results indicated that the system could map ECG signals accurately and the quality of the signals was good. The improvement of hardware and enhancement of software made the system suitable for mapping in different situations. So the primary development of the software for oversampling mapping system was successful and further research and development can make the system a powerful tool for researching ECG inverse problem.
Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S
2007-03-01
This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.
Gay, Estelle; Bornallet, Géraldine; Gaucherand, Pascal; Doret, Muriel
2015-11-01
To assess if the fetal electrocardiogram especially ST segment is modified by congenital heart diseases: modifications in frequencies of the different ST events and modifications in signal quality. A retrospective case-control study, comparing frequencies of the different ST events and the quality of the signal between fetuses with congenital heart diseases and fetuses without congenital heart disease. From 2000 to 2011, fifty-eight fetuses with congenital heart disease had their heart rate recording using a STAN device during labor. Control group was fetuses who were born just before a case and had a STAN as a second line for intrapartum surveillance. Cases and controls were matched on parity, gestational age at birth, presence of growth restriction and umbilical artery pH. Frequencies of the different ST event and quality of the signal were first analyzed for the global labor recording, and then separately for the first and the second phase of labor. No statistically significant difference in ST event frequencies between fetuses with congenital heart disease and the control group was found. Regarding the quality of the signal, 11.49% (±18.82) of recording time is a signal loss for fetus with congenital heart disease whereas only 5.18% (±10.67) for the control group (p=0.028). This is the first study investigating for intrapartum electrocardiogram modification in fetus with congenital heart disease. Congenital heart diseases do not modify frequencies of ST events. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Effect of gender on computerized electrocardiogram measurements in college athletes.
Mandic, Sandra; Fonda, Holly; Dewey, Frederick; Le, Vy-van; Stein, Ricardo; Wheeler, Matt; Ashley, Euan A; Myers, Jonathan; Froelicher, Victor F
2010-06-01
Broad criteria for classifying an electrocardiogram (ECG) as abnormal and requiring additional testing prior to participating in competitive athletics have been recommended for the preparticipation examination (PPE) of athletes. Because these criteria have not considered gender differences, we examined the effect of gender on the computerized ECG measurements obtained on Stanford student athletes. Currently available computer programs require a basis for "normal" in athletes of both genders to provide reliable interpretation. During the 2007 PPE, computerized ECGs were recorded and analyzed on 658 athletes (54% male; mean age, 19 +/- 1 years) representing 22 sports. Electrocardiogram measurements included intervals and durations in all 12 leads to calculate 12-lead voltage sums, QRS amplitude and QRS area, spatial vector length (SVL), and the sum of the R wave in V5 and S wave in V2 (RSsum). By computer analysis, male athletes had significantly greater QRS duration, PR interval, Q-wave duration, J-point amplitude, and T-wave amplitude, and shorter QTc interval compared with female athletes (all P < 0.05). All ECG indicators of left ventricular electrical activity were significantly greater in males. Although gender was consistently associated with indices of atrial and ventricular electrical activity in multivariable analysis, ECG measurements correlated poorly with body dimensions. Significant gender differences exist in ECG measurements of college athletes that are not explained by differences in body size. Our tables of "normal" computerized gender-specific measurements can facilitate the development of automated ECG interpretation for screening young athletes.
Arrhythmic hazard map for a 3D whole-ventricles model under multiple ion channel block.
Okada, Jun-Ichi; Yoshinaga, Takashi; Kurokawa, Junko; Washio, Takumi; Furukawa, Tetsushi; Sawada, Kohei; Sugiura, Seiryo; Hisada, Toshiaki
2018-05-10
To date, proposed in silico models for preclinical cardiac safety testing are limited in their predictability and usability. We previously reported a multi-scale heart simulation that accurately predicts arrhythmogenic risk for benchmark drugs. We extend this approach and report the first comprehensive hazard map of drug-induced arrhythmia based on the exhaustive in silico electrocardiogram (ECG) database of drug effects, developed using a petaflop computer. A total of 9075 electrocardiograms constitute the five-dimensional hazard map, with coordinates representing the extent of the block of each of the five ionic currents (rapid delayed rectifier potassium current (IKr), fast (INa) and late (INa,L) components of the sodium current, L-type calcium current (ICa,L) and slow delayed rectifier current (IKs)), involved in arrhythmogenesis. Results of the evaluation of arrhythmogenic risk based on this hazard map agreed well with the risk assessments reported in three references. ECG database also suggested that the interval between the J-point and the T-wave peak is a superior index of arrhythmogenicity compared to other ECG biomarkers including the QT interval. Because concentration-dependent effects on electrocardiograms of any drug can be traced on this map based on in vitro current assay data, its arrhythmogenic risk can be evaluated without performing costly and potentially risky human electrophysiological assays. Hence, the map serves as a novel tool for use in pharmaceutical research and development. This article is protected by copyright. All rights reserved.
Ziakas, Antonios; Basagiannis, Christos; Stiliadis, Ioannis
2010-04-26
A rare electrocardiographic finding of hyperkalemia is ST segment elevation or the so called 'pseudoinfarction' pattern. It has been suggested that hyperkalemia causes the 'pseudoinfarction' pattern not only through its direct myocardial effects, but also through other mechanisms, such as anoxia, acidosis, and coronary artery spasm. A 33-year-old Caucasian woman with insulin-treated diabetes presented with continuous epigastric pain of four hours duration. Her coronary heart disease risk factors apart from diabetes included hypercholesterolemia and smoking. Her initial electrocardiogram revealed ST segment elevation in the anteroseptal leads consistent with anterior myocardial infarction. Blood tests revealed hyperglycemia, hyperkalemia, metabolic acidosis and urine ketones, while a bed-side cardiac echocardiogram showed no segmental wall motion abnormality. We provisionally diagnosed diabetic ketoacidosis that was possibly precipitated by acute myocardial infarction, as there were findings in favor of (epigastric pain, electrocardiogram pattern, presence of 3 coronary heart disease risk factors) and against (young age, normal echocardiogram) the diagnosis of acute myocardial infarction. We performed cardiac angiography in order to exclude an anterior acute myocardial infarction, which could lead to myocardial damage and possible severe complications should there be a delay in treatment. Angiography revealed normal coronary arteries. During the procedure, ST segment elevation in the anteroseptal leads was still present in our patient's electrocardiogram results. ST segment elevation is a rare manifestation of hyperkalemia. In our patient, coronary spasm did not contribute to such an electrocardiography finding.
Jiang, Jianbin; He, Yuee; Qiu, Huixian; Zhang, Yuanhai; Chu, Maoping; Li, Yuechun; Chen, Qi
2017-10-21
Up to 40% of healthy children have premature ventricular complexes or contractions (PVCs) detected with 24-hour Holter monitoring. We aimed to investigate the morphological characteristics and origins of idiopathic PVCs under a 12-lead electrocardiogram in children with structurally normal hearts. All asymptomatic monomorphic PVC patients with structurally normal hearts under 18 years of age were included in this retrospective study. Characteristics of PVCs in lead V 1 under a 12-lead electrocardiogram were classified as left bundle branch block (PVC-LBBB) or right bundle branch block (PVC-RBBB). According to limb leads, PVC-LBBB or PVC-RBBB was divided into: PVCs-LBBB type I; PVCs-LBBB type II; PVCs-RBBB type I; PVCs-RBBB type II; and PVCs-RBBB type III. Out of 178 PVC patients, 94 cases of PVCs-LBBB (PVCs-LBBB type I = 60; PVCs-LBBB type II = 34) and 84 cases of PVCs-RBBB (PVCs-RBBB type I = 3; PVCs-RBBB type II = 55; PVCs-RBBB type III = 26) were identified. The frequency of PVCs-LBBB type I increased with age and the frequency of PVCs-RBBB type II and III decreased with age. Among the children monitor tested, from 1 years old to 18 years old, PVCs originating from the left or right ventricular outflow tract gradually increased with age, while PVCs originating from the branch sources decreased with age.
EMG (Electromyography) (For Parents)
... topic for: Parents Kids Teens ECG (Electrocardiogram) Muscular Dystrophy Bones, Muscles, and Joints EEG (Electroencephalogram) Getting an EKG (Video) Medical Tests and Procedures (Video Landing Page) EKG (Video) Medical Tests: What to Expect ... About Us Contact Us Partners Editorial ...
... clinical research. More Information Related Health Topics Asbestos-Related Lung Diseases Asthma Chest X-Ray COPD Cough Electrocardiogram Heart Failure How the Lungs Work Idiopathic Pulmonary Fibrosis Oxygen Therapy Sarcoidosis Stress Testing NHLBI Resources Taking a Spirometry Test Building ...
21 CFR 870.1220 - Electrode recording catheter or electrode recording probe.
Code of Federal Regulations, 2010 CFR
2010-04-01
... electrocardiogram, or to detect cardiac output or left-to-right heart shunts. The device may be unipolar or... a special indicator for cardiac output or left-to-right heart shunt determinations. (b...
21 CFR 870.1220 - Electrode recording catheter or electrode recording probe.
Code of Federal Regulations, 2011 CFR
2011-04-01
... electrocardiogram, or to detect cardiac output or left-to-right heart shunts. The device may be unipolar or... a special indicator for cardiac output or left-to-right heart shunt determinations. (b...
21 CFR 870.1220 - Electrode recording catheter or electrode recording probe.
Code of Federal Regulations, 2012 CFR
2012-04-01
... electrocardiogram, or to detect cardiac output or left-to-right heart shunts. The device may be unipolar or... a special indicator for cardiac output or left-to-right heart shunt determinations. (b...
21 CFR 870.1220 - Electrode recording catheter or electrode recording probe.
Code of Federal Regulations, 2013 CFR
2013-04-01
... electrocardiogram, or to detect cardiac output or left-to-right heart shunts. The device may be unipolar or... a special indicator for cardiac output or left-to-right heart shunt determinations. (b...
21 CFR 870.1220 - Electrode recording catheter or electrode recording probe.
Code of Federal Regulations, 2014 CFR
2014-04-01
... electrocardiogram, or to detect cardiac output or left-to-right heart shunts. The device may be unipolar or... a special indicator for cardiac output or left-to-right heart shunt determinations. (b...
The pre-operative electrocardiogram: an assessment.
Paterson, K R; Caskie, J P; Galloway, D J; McArthur, K; McWhinnie, D L
1983-04-01
Electrocardiography is of limited value in pre-operative screening for cardiac disease. A short questionnaire has been shown to be helpful in assessing cardiac status and could permit a 30% reduction in the number of pre-operative ECGs performed.
Second-Degree Atrioventricular Block Occurring After Tooth Extraction.
Kamatani, Takaaki; Akizuki, Ayako; Kondo, Seiji; Shirota, Tatsuo
Although cardiac arrhythmias are occasionally associated with dental extractions and dental anesthesia, atrioventricular block is rarely seen during dental procedures. We report a rare case of type I second-degree atrioventricular block (Wenckebach phenomenon) occurring after bilateral extraction of impacted mandibular third molars under general anesthesia in a 16-year-old Japanese girl. Under consultation with a cardiovascular physician, we carefully monitored the patient's vital signs postoperatively, including blood pressure, oxygen saturation, and electrocardiogram, using a bedside monitor. Her postoperative course was uneventful. A 12-lead electrocardiogram the following day revealed no abnormality. In this case, we hypothesize that extubation of the nasotracheal tube or oral/pharyngeal suction might have triggered a vagal reflex that caused type I second-degree atrioventricular block. Our experience indicates that standard cardiovascular monitoring should be used for patients undergoing dental treatment under general anesthesia, even for young, healthy patients, to prevent and detect cardiovascular emergencies.
ECG signal analysis through hidden Markov models.
Andreão, Rodrigo V; Dorizzi, Bernadette; Boudy, Jérôme
2006-08-01
This paper presents an original hidden Markov model (HMM) approach for online beat segmentation and classification of electrocardiograms. The HMM framework has been visited because of its ability of beat detection, segmentation and classification, highly suitable to the electrocardiogram (ECG) problem. Our approach addresses a large panel of topics some of them never studied before in other HMM related works: waveforms modeling, multichannel beat segmentation and classification, and unsupervised adaptation to the patient's ECG. The performance was evaluated on the two-channel QT database in terms of waveform segmentation precision, beat detection and classification. Our waveform segmentation results compare favorably to other systems in the literature. We also obtained high beat detection performance with sensitivity of 99.79% and a positive predictivity of 99.96%, using a test set of 59 recordings. Moreover, premature ventricular contraction beats were detected using an original classification strategy. The results obtained validate our approach for real world application.
Reconfigurable Embedded System for Electrocardiogram Acquisition.
Kay, Marcel Seiji; Iaione, Fábio
2015-01-01
Smartphones include features that offers the chance to develop mobile systems in medical field, resulting in an area called mobile-health. One of the most common medical examinations is the electrocardiogram (ECG), which allows the diagnosis of various heart diseases, leading to preventative measures and preventing more serious problems. The objective of this study was to develop a wireless reconfigurable embedded system using a FPAA (Field Programmable Analog Array), for the acquisition of ECG signals, and an application showing and storing these signals on Android smartphones. The application also performs the partial FPAA reconfiguration in real time (adjustable gain). Previous studies using FPAA usually use the development boards provided by the manufacturer (high cost), do not allow the reconfiguration in real time, use no smartphone and communicate via cables. The parameters tested in the acquisition circuit and the quality of ECGs registered in an individual were satisfactory.
Kumar, Kris; Lotun, Kapildeo
2018-05-07
Out of hospital cardiac arrest management of patients with non-ST myocardial infarction per current American Heart Association and European Resuscitation Council guidelines leave the decision in regard to early angiography up to the physician operators. Guidelines are clear on the positive impact of early intervention on survival and improvement on left ventricular function in patients presenting with cardiac arrest and ST elevation myocardial infarction on electrocardiogram. This review aims to analyze the data that current guidelines are based upon in regards to out of hospital cardiac arrest with electrocardiogram findings of non-ST elevation myocardial infarction as well as other clinical trials that support early angiography and reperfusion strategies as well as future studies that are in trial to study the role of the coronary catheterization laboratory in cardiac arrest. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System
Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk
2016-01-01
In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user’s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user’s high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user’s daily smartphone use. PMID:26978364
Evaluation of an electrocardiogram on QR code.
Nakayama, Masaharu; Shimokawa, Hiroaki
2013-01-01
An electrocardiogram (ECG) is an indispensable tool to diagnose cardiac diseases, such as ischemic heart disease, myocarditis, arrhythmia, and cardiomyopathy. Since ECG patterns vary depend on patient status, it is also used to monitor patients during treatment and comparison with ECGs with previous results is important for accurate diagnosis. However, the comparison requires connection to ECG data server in a hospital and the availability of data connection among hospitals is limited. To improve the portability and availability of ECG data regardless of server connection, we here introduce conversion of ECG data into 2D barcodes as text data and decode of the QR code for drawing ECG with Google Chart API. Fourteen cardiologists and six general physicians evaluated the system using iPhone and iPad. Overall, they were satisfied with the system in usability and accuracy of decoded ECG compared to the original ECG. This new coding system may be useful in utilizing ECG data irrespective of server connections.
Kim, Diana H; Verdino, Ralph J
To define clinical correlates of low voltage isolated to precordial leads on the surface electrocardiogram (ECG). Low voltage (V) on the ECG is defined as QRS V<5mm in all limb leads and <10mm in all precordial leads. The diagnostic use of ECGs with low voltage isolated to the precordial leads with normal limb lead voltages is unclear. Twelve-lead ECGs with QRS V>5mm in one or more limb leads and <10mm in all precordial leads were collected. Associated clinical conditions were determined from clinical data, echocardiograms, and chest radiographs. Low precordial voltage was found in 256 of 150,000 ECGs (~0.2%). 50.4% of patients had discordant ECGs that correlated with classic etiologies, with a higher incidence of LV dilation in those with classic etiologies than those without. Low precordial voltage is associated with classic etiologies and LV dilation. Copyright © 2017 Elsevier Inc. All rights reserved.
Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System.
Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk
2016-03-11
In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user's ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user's high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user's daily smartphone use.
[Low-power Wireless Micro Ambulatory Electrocardiogram Node].
Cai, Zhipeng; Luo, Kan; Li, Jianqing
2016-02-01
Ambulatory electrocardiogram (ECG) monitoring can effectively reduce the risk and death rate of patients with cardiovascular diseases (CVDs). The Body Sensor Network (BSN) based ECG monitoring is a new and efficien method to protect the CVDs patients. To meet the challenges of miniaturization, low power and high signal quality of the node, we proposed a novel 50 mmX 50 mmX 10 mm, 30 g wireless ECG node, which includes the single-chip an alog front-end AD8232, ultra-low power microprocessor MSP430F1611 and Bluetooth module HM-11. The ECG signal quality is guaranteed by the on-line digital filtering. The difference threshold algorithm results in accuracy of R-wave detection and heart rate. Experiments were carried out to test the node and the results showed that the pro posed node reached the design target, and it has great potential in application of wireless ECG monitoring.
Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 3
NASA Technical Reports Server (NTRS)
Mark, R. G.
1975-01-01
The following subjects were covered: (1) ASM80 manual, (2) signal preprocessing as an aid to on-line EKG analysis, and (3) high speed evaluation of magnetic tape recordings of electrocardiograms. A description of the ASM80 symbolic assembly program for the INTEL 8080 microprocessor and a user's manual were presented. The capability of three redundancy reduction algorithms to produce adequate representations of electrocardiographic data was examined. A hardware device was constructed which carried out zero order interpolation on a signal. Examination of the zero order interpolators reconstructed signal indicated that this representation was adequate for analysis of rhythm. A system to analyze magnetic tapes of electrocardiograms recorded over 24 hour intervals was designed. The recordings are sampled 200 times per second using a Nova computer and a special interface system. This system was tested on several recordings of clinical data, containing over 75 premature ventricular contractions, each one of which was flagged.
Electrocardiogram Changes with Acute Alcohol Intoxication: A Systematic Review.
Raheja, Hitesh; Namana, Vinod; Chopra, Kirti; Sinha, Ankur; Gupta, Sushilkumar Satish; Kamholz, Stephan; Moskovits, Norbert; Shani, Jacob; Hollander, Gerald
2018-01-01
Acute alcohol intoxication has been associated with cardiac arrhythmias but the electrocardiogram (ECG) changes associated with acute alcohol intoxication are not well defined in the literature. Highlight the best evidence regarding the ECG changes associated with acute alcohol intoxication in otherwise healthy patients and the pathophysiology of the changes. A literature search was carried out; 4 studies relating to ECG changes with acute alcohol intoxication were included in this review. Of the total 141 patients included in the review, 90 (63.8%) patients had P-wave prolongation, 80 (56%) patients had QTc prolongation, 19 (13.5%) patients developed T-wave abnormalities, 10 (7%) patients had QRS complex prolongation, 3 (2.12%) patients developed ST-segment depressions. The most common ECG changes associated with acute alcohol intoxication are (in decreasing order of frequency) P-wave and QTc prolongation, followed by T-wave abnormalities and QRS complex prolongation. Mostly, these changes are completely reversible.
Butrous, G S; Meldrum, S J; Barton, D G; Male, J C; Bonnell, J A; Camm, A J
1982-05-01
The effect on an implanted, multiprogrammable pacemaker of power-frequency (50 Hz) electric fields up to an intensity (unperturbed value measured at 1.7 m) of 20 kV/m were assessed in ten paced patients. Radiotelemetric monitoring of the electrocardiogram allowed supervision of the electrocardiogram throughout exposure to the alternating electric field. Displacement body currents of up to 300μA were achieved depending on the position and height of the patient. None of the pacemakers was inhibited, triggered or reverted to fixed rate operation during the exposure. The programmable functions, programmability or output characteristics were not affected. Small changes in cardiac rate and rhythm elicited the correct pacemaker responses. Unlike earlier models of pacemaker, this modern implanted pacemaker, which represents `the state of the art', is not affected by 50 Hz electric fields likely to be encountered when standing underneath power lines.
Isolated papillary muscle hypertrophy: A gap in our knowledge of hypertrophic cardiomyopathy?
Ferreira, Catarina; Delgado, Carlos; Vázquez, María; Trinidad, Carmen; Vilar, Manuel
2014-06-01
Increased thickness of left ventricular walls is the predominant characteristic and one of the diagnostic criteria of hypertrophic cardiomyopathy (HCM). This case illustrates an uncommon but important finding of isolated hypertrophy of the papillary muscles (PMs), observed in a young woman in whom an abnormal electrocardiogram was initially detected. During the investigation isolated PM hypertrophy was identified. The structural characteristics of the PMs have received scant attention in this setting and there is little information in the literature on this entity, whose real prevalence and clinical significance remain to be determined. The available information relates solitary PM hypertrophy with an early form or a different pattern of HCM. In this case PM hypertrophy was only detected due to the finding of an abnormal electrocardiogram, which prompted further diagnostic tests and a search for possible etiologies. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
III Lead ECG Pulse Measurement Sensor
NASA Astrophysics Data System (ADS)
Thangaraju, S. K.; Munisamy, K.
2015-09-01
Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.
Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S; Josephson, Mark; Mason, Jay W; Okin, Peter; Surawicz, Borys; Wellens, Hein
2007-03-13
This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.
Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S; Josephson, Mark; Mason, Jay W; Okin, Peter; Surawicz, Borys; Wellens, Hein
2007-03-13
This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.
Vivo, Rey P; Krim, Selim R; Hodgson, John
2008-11-01
We describe a 65-year-old woman with a history of hypertension and smoking who presented with an acute episode of chest pain precipitated by severe emotional stress. Her initial electrocardiogram done in the emergency room showed non-specific T wave changes in the lateral leads and her cardiac troponin levels were mildly elevated. Because of her clinical presentation, she was admitted with a presumptive diagnosis of acute myocardial infarction and managed with antiplatelet and anticoagulant therapy. Coronary angiogram did not reveal coronary artery disease and left ventriculography showed findings consistent with apical ballooning syndrome or takotsubo cardiomyopathy. Subsequent electrocardiograms displayed dramatic changes including T wave inversions, QT interval prolongation and U waves. The patient remained asymptomatic and recovered uneventfully. Three weeks post-discharge, an echocardiogram documented resolved left ventricular dysfunction. We describe the clinical features and highlight the electrocardiographic findings that may help differentiate takotsubo cardiomyopathy from myocardial infarction.
Trend Extraction in Functional Data of Amplitudes of R and T Waves in Exercise Electrocardiogram
NASA Astrophysics Data System (ADS)
Cammarota, Camillo; Curione, Mario
The amplitudes of R and T waves of the electrocardiogram (ECG) recorded during the exercise test show both large inter- and intra-individual variability in response to stress. We analyze a dataset of 65 normal subjects undergoing ambulatory test. We model the dataset of R and T series in the framework of functional data, assuming that the individual series are realizations of a non-stationary process, centered at the population trend. We test the time variability of this trend computing a simultaneous confidence band and the zero crossing of its derivative. The analysis shows that the amplitudes of the R and T waves have opposite responses to stress, consisting respectively in a bump and a dip at the early recovery stage. Our findings support the existence of a relationship between R and T wave amplitudes and respectively diastolic and systolic ventricular volumes.
Chagas Cardiomyopathy: Usefulness of EKG and Echocardiogram in a Non-Endemic Country
Sánchez-Montalvá, Adrián; Salvador, Fernando; Rodríguez-Palomares, José; Sulleiro, Elena; Sao-Avilés, Augusto; Roure, Sílvia; Valerio, Lluís; Evangelista, Arturo; Molina, Israel
2016-01-01
Background Chagas disease (CD) is a major cause of cardiomyopathy in Latin America, and migration movements have now spread the disease worldwide. However, data regarding Chagas cardiomyopathy (CC) and the usefulness of echocardiography in non endemic countries are still scarce. Methods and results We selected 485 patients in the chronic phase of CD from two Spanish settings. Data from physical examination, electrocardiogram (EKG), x-ray, and two dimensional transthoracic echocardiogram were recorded. Trypanosoma cruzi DNA was assessed by PCR in peripheral blood. Patients were stratified according to the Kuschnir classification and a combination of echocardiogram and electrocardiogram findings. Patients mainly came from Bolivia (459; 94.6%). One hundred and forty three patients (31.5%) had at least one electrocardiogram abnormality. Twenty seven patients (5.3%) had an abnormal echocardiography. Patients with abnormal echocardiography were older (47 (IQR 38–57) years vs 41 (IQR 38–57) years); p = 0.019) and there was a greater proportion of males (66.7% vs 29.7%); p<0.001). Among echocardiographic variables, diastolic dysfunction was associated with poor cardiac status. In the multivariate analysis, abnormal EKG and gender were associated with abnormal echocardiography. Echocardiography may be spared for males under 30 and females under 45 years old with normal EKG as the likelihood of having an abnormal echocardiography is minimal. Association between T. cruzi DNA in the peripheral blood and cardiac involvement was not observed. Conclusion CC rates in the studied population are low. Age and sex are important determinants for the development of CC, and with the EKG should guide echocardiogram performance. PMID:27308824
Development of electrocardiogram intervals during growth of FVB/N neonate mice
2010-01-01
Background Electrocardiography remains the best diagnostic tool and therapeutic biomarker for a spectrum of pediatric diseases involving cardiac or autonomic nervous system defects. As genetic links to these disorders are established and transgenic mouse models produced in efforts to understand and treat them, there is a surprising lack of information on electrocardiograms (ECGs) and ECG abnormalities in neonate mice. This is likely due to the trauma and anaesthesia required of many legacy approaches to ECG recording in mice, exacerbated by the fragility of many mutant neonates. Here, we use a non-invasive system to characterize development of the heart rate and electrocardiogram throughout the growth of conscious neonate FVB/N mice. Results We examine ECG waveforms as early as two days after birth. At this point males and females demonstrate comparable heart rates that are 50% lower than adult mice. Neonatal mice exhibit very low heart rate variability. Within 12 days of birth PR, QRS and QTc interval durations are near adult values while heart rate continues to increase until weaning. Upon weaning FVB/N females quickly develop slower heart rates than males, though PR intervals are comparable between sexes until a later age. This suggests separate developmental events may contribute to these gender differences in electrocardiography. Conclusions We provide insight with a new level of detail to the natural course of heart rate establishment in neonate mice. ECG can now be conveniently and repeatedly used in neonatal mice. This should serve to be of broad utility, facilitating further investigations into development of a diverse group of diseases and therapeutics in preclinical mouse studies. PMID:20735846
Kinsman, Leigh D; Rotter, Thomas; Willis, Jon; Snow, Pamela C; Buykx, Penny; Humphreys, John S
2012-04-01
The objective of this study is to measure the impact of a five-step implementation process for an acute myocardial infarction (AMI) clinical pathway (CPW) on thrombolytic administration in rural emergency departments. Cluster randomised controlled trial. Six rural Victorian emergency departments participated. The five-step CPW implementation process comprised (i) engaging clinicians; (ii) CPW development; (iii) reminders; (iv) education; and (v) audit and feedback. The impact of the intervention was assessed by measuring the proportion of eligible AMI patients receiving a thrombolytic and time to thrombolysis and electrocardiogram. Nine hundred and fifteen medical records were audited, producing a final sample of 108 patients eligible for thrombolysis. There was no significant difference between intervention and control groups for median door-to-needle time (29 mins versus 29 mins; P = 0.632), proportion of those eligible receiving a thrombolytic (78% versus 84%; P = 0.739), median time to electrocardiogram (7 mins versus 6 mins; P = 0.669) and other outcome measures. Results showed superior outcome measures than other published studies. The lack of impact of the implementation process for a chest pain CPW on thrombolytic delivery or time to electrocardiogram in these rural hospitals can be explained by a ceiling effect in outcome measures but was also compromised by the small sample. Results suggest that quality of AMI treatment in rural emergency departments (EDs) is high and does not contribute to the worse mortality rate reported for AMIs in rural areas. © 2012 The Authors. Australian Journal of Rural Health © 2012 National Rural Health Alliance Inc.
Accuracy of smartphone apps for heart rate measurement.
Coppetti, Thomas; Brauchlin, Andreas; Müggler, Simon; Attinger-Toller, Adrian; Templin, Christian; Schönrath, Felix; Hellermann, Jens; Lüscher, Thomas F; Biaggi, Patric; Wyss, Christophe A
2017-08-01
Background Smartphone manufacturers offer mobile health monitoring technology to their customers, including apps using the built-in camera for heart rate assessment. This study aimed to test the diagnostic accuracy of such heart rate measuring apps in clinical practice. Methods The feasibility and accuracy of measuring heart rate was tested on four commercially available apps using both iPhone 4 and iPhone 5. 'Instant Heart Rate' (IHR) and 'Heart Fitness' (HF) work with contact photoplethysmography (contact of fingertip to built-in camera), while 'Whats My Heart Rate' (WMH) and 'Cardiio Version' (CAR) work with non-contact photoplethysmography. The measurements were compared to electrocardiogram and pulse oximetry-derived heart rate. Results Heart rate measurement using app-based photoplethysmography was performed on 108 randomly selected patients. The electrocardiogram-derived heart rate correlated well with pulse oximetry ( r = 0.92), IHR ( r = 0.83) and HF ( r = 0.96), but somewhat less with WMH ( r = 0.62) and CAR ( r = 0.60). The accuracy of app-measured heart rate as compared to electrocardiogram, reported as mean absolute error (in bpm ± standard error) was 2 ± 0.35 (pulse oximetry), 4.5 ± 1.1 (IHR), 2 ± 0.5 (HF), 7.1 ± 1.4 (WMH) and 8.1 ± 1.4 (CAR). Conclusions We found substantial performance differences between the four studied heart rate measuring apps. The two contact photoplethysmography-based apps had higher feasibility and better accuracy for heart rate measurement than the two non-contact photoplethysmography-based apps.
Faber, Thomas S; Gradinger, Robert; Treusch, Sven; Morkel, Carsten; Brachmann, Johannes; Bode, Christoph; Zehender, Manfred
2007-09-01
Current studies found an incidence of 12-31% ventricular tachyarrhythmias and sudden cardiac death during cardiac pacing months or even years after pacemaker insertion. MADIT(12) and MUSTT(13) demonstrated that patients with poor LV function after Myocardial infarction (MI) showing non-sustained ventricular tachycardia (nsVT) and inducibility during electrophysiologic testing benefit from an ICD. The present study was dedicated to assess the global incidence of non-sustained ventricular arrhythmias in a general population of pacemaker patients. Special regard was on patients with a potential ICD indication, e.g. those matching the MADIT/MUSTT criteria. Two hundred and thirty-one patients (72 +/- 11 years; 134 men) with an indication for dual chamber pacing entered the study. In all patients pacemaker systems capable of automatic storing of intracardiac electrocardiograms were implanted (Pulsar, Discovery, Guidant). Follow-up time was 15 months after inclusion. In 54 (25.7%) of 210 patients with at least one follow-up, episodes of nsVT were documented by stored electrocardiograms (up to >30 beats, >200 b.p.m.). Multiple-up to nine-episodes of ventricular tachycardia were retrieved in 31 of these patients. Three out of 14 patients with an LVEF <40% after MI presented nsVT during the follow-up. One of these patients received an ICD. A significant number of pacemaker patients present with ventricular tachycardia. Intracardiac electrocardiograms and alert functions from pacemakers may enhance physicians' awareness of the patient's intrinsic arrhythmic profile and help uncover underlying mechanisms of arrhythmias by storing the initiation of the arrhythmia.
Palhares, Daniel M F; Marcolino, Milena S; Santos, Thales M M; da Silva, José L P; Gomes, Paulo R; Ribeiro, Leonardo B; Macfarlane, Peter W; Ribeiro, Antonio L P
2017-06-13
Knowledge of the normal limits of the electrocardiogram (ECG) is mandatory for establishing which patients have abnormal ECGs. No studies have assessed the reference standards for a Latin American population. Our aim was to establish the normal ranges of the ECG for pediatric and adult Brazilian primary care patients. This retrospective observational study assessed all the consecutive 12-lead digital electrocardiograms of primary care patients at least 1 year old in Minas Gerais state, Brazil, recorded between 2010 and 2015. ECGs were excluded if there were technical problems, selected abnormalities were present or patients with selected self-declared comorbidities or on drug therapy. Only the first ECG from patients with multiple ECGs was accepted. The University of Glasgow ECG analysis program was used to automatically interpret the ECGs. For each variable, the 1st, 2nd, 50th, 98th and 99th percentiles were determined and results were compared to selected studies. A total of 1,493,905 ECGs were recorded. 1,007,891 were excluded and 486.014 were analyzed. This large study provided normal values for heart rate, P, QRS and T frontal axis, P and QRS overall duration, PR and QT overall intervals and QTc corrected by Hodges, Bazett, Fridericia and Framingham formulae. Overall, the results were similar to those from other studies performed in different populations but there were differences in extreme ages and specific measurements. This study has provided reference values for Latinos of both sexes older than 1 year. Our results are comparable to studies performed in different populations.
Pimentel, Alan Santos; Alves, Eduardo da Silva; Alvim, Rafael de Oliveira; Nunes, Rogério Tasca; Costa, Carlos Magno Amaral; Lovisi, Júlio Cesar Moraes; Perrout de Lima, Jorge Roberto
2010-05-01
The 4-second exercise test (T4s) evaluates the cardiac vagal tone during the initial heart rate (HR) transient at sudden dynamic exercise, through the identification of the cardiac vagal index (CVI) obtained from the electrocardiogram (ECG). To evaluate the use of the Polar S810 heart rate monitor (HRM) as an alternative resource to the use of the electrocardiogram in the 4-second exercise test. In this study, 49 male individuals (25 +/- 20 years, 176 +/-12 cm, 74 +/- 6 kg) underwent the 4-second exercise test. The RR intervals were recorded simultaneously by ECG and HRM. We calculated the mean and the standard deviation of the last RR interval of the pre-exercise period, or of the first RR interval of the exercise period, whichever was longer (RRB), of the shortest RR interval of the exercise period (RRC), and of the CVI obtained by ECG and HRM. We used the Student t-test for dependent samples (p < or 0.05) to test the significance of the differences between means. To identify the correlation between the ECG and the HRM, we used the linear regression to calculate the Pearson's correlation coefficient and the strategy proposed by Bland and Altman. Linear regression showed r(2) of 0.9999 for RRB, 0.9997 for RRC, and 0.9996 for CVI. Bland e Altman strategy presented standard deviation of 0.92 ms for RRB, 0.86 ms for RRC, and 0.002 for CVI. Polar S810 HRM was more efficient in the application of T4s compared to the ECG.
Compression and R-wave detection of ECG/VCG data
NASA Technical Reports Server (NTRS)
Hayden, W. L.; Conover, M. F.; Bennett, W. P.
1972-01-01
Application of information theory to eliminate redundant part of electrocardiogram or vectorcardiogram is described. Operation of medical equipment to obtain three dimensional study of patient is discussed. Use of fast Fourier transform to accomplish data compression is explained.
NASA Technical Reports Server (NTRS)
Rinard, G. A.; Steffen, D. A.; Sturm, R. E.
1979-01-01
Circuit with high common-mode rejection has ability to filter and amplify accepted analog electrocardiogram (ECG) signals of varying amplitude, shape, and polarity. In addition, low power circuit develops standardized pulses that can be counted and averaged by heart/breath rate processor.
2001-10-25
34 An Introduction to statsitical signal processing". Stanford University and University of Maryland, 1996 [8]Donna Van Wynsberge, Charles R. Noback , Robert Carola " Human Anatomy and Physiology" third edition, 1996
Catheter-tip force transducer for cardiovascular research
NASA Technical Reports Server (NTRS)
Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H.
1975-01-01
Sensor can be installed in left ventricle by means of procedures available for inserting catheter into an artery at body's extremities and manipulating it through vessel and past aortic valve. Metallic tines of device can be used as internal electrode for electrocardiogram.
20 CFR 404.1528 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2010 CFR
2010-04-01
....1528 Section 404.1528 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc.), roentgenological studies (X-rays), and psychological tests. [45 FR 55584, Aug. 20, 1980, as amended at 65 FR 50775...
20 CFR 404.1528 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2012 CFR
2012-04-01
....1528 Section 404.1528 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc.), roentgenological studies (X-rays), and psychological tests. [45 FR 55584, Aug. 20, 1980, as amended at 65 FR 50775...
20 CFR 404.1528 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2011 CFR
2011-04-01
....1528 Section 404.1528 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc.), roentgenological studies (X-rays), and psychological tests. [45 FR 55584, Aug. 20, 1980, as amended at 65 FR 50775...
20 CFR 404.1528 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2013 CFR
2013-04-01
....1528 Section 404.1528 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc.), roentgenological studies (X-rays), and psychological tests. [45 FR 55584, Aug. 20, 1980, as amended at 65 FR 50775...
20 CFR 404.1528 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2014 CFR
2014-04-01
....1528 Section 404.1528 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc.), roentgenological studies (X-rays), and psychological tests. [45 FR 55584, Aug. 20, 1980, as amended at 65 FR 50775...
The Physics of Physical Examinations.
ERIC Educational Resources Information Center
Patterson, James D.
1989-01-01
Discussed are several topics on medical imaging including x-rays and Computer Assisted Tomography (CAT) scans, magnetic resonance imaging, fiber optics endoscopy, nuclear medicine and bone scans, positron-emission tomography, and ultrasound. The concepts of radiation dosage, electrocardiograms, and laser therapy are included. (YP)
47 CFR 95.1117 - Types of communications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Types of communications. 95.1117 Section 95.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... care. Waveforms such as electrocardiograms (ECGs) are not considered video. (b) Operations that comply...
47 CFR 95.1117 - Types of communications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Types of communications. 95.1117 Section 95.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... care. Waveforms such as electrocardiograms (ECGs) are not considered video. (b) Operations that comply...
20 CFR 416.928 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2011 CFR
2011-04-01
... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...
20 CFR 416.928 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2010 CFR
2010-04-01
... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...
20 CFR 416.928 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2014 CFR
2014-04-01
... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...
20 CFR 416.928 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2013 CFR
2013-04-01
... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...
20 CFR 416.928 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2012 CFR
2012-04-01
... or mental impairment. If you are a child under age 18 and are unable to adequately describe your... abnormalities, e.g., abnormalities of behavior, mood, thought, memory, orientation, development, or perception... include chemical tests, electrophysiological studies (electrocardiogram, electroencephalogram, etc...
Development of engineering prototype of Life Support Module (LSM)
NASA Technical Reports Server (NTRS)
1984-01-01
The development of an engineering prototype of a life support system is discussed. The module consists of an electrocardiogram, a defibrillator, a resuscitator, and an aspirator, as well as body temperature and blood pressure measuring instruments. A drug kit is included.
20 CFR 404.1519f - Type of purchased examinations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false Type of purchased examinations. 404.1519f Section 404.1519f Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... studies, or an electrocardiogram. [56 FR 36956, Aug. 1, 1991] ...
20 CFR 404.1519f - Type of purchased examinations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Type of purchased examinations. 404.1519f Section 404.1519f Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... studies, or an electrocardiogram. [56 FR 36956, Aug. 1, 1991] ...
20 CFR 404.1519f - Type of purchased examinations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Type of purchased examinations. 404.1519f Section 404.1519f Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... studies, or an electrocardiogram. [56 FR 36956, Aug. 1, 1991] ...
20 CFR 416.919f - Type of purchased examinations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Type of purchased examinations. 416.919f Section 416.919f Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE... studies, or an electrocardiogram. [56 FR 36965, Aug. 1, 1991] ...
20 CFR 416.919f - Type of purchased examinations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false Type of purchased examinations. 416.919f Section 416.919f Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE... studies, or an electrocardiogram. [56 FR 36965, Aug. 1, 1991] ...
20 CFR 416.919f - Type of purchased examinations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Type of purchased examinations. 416.919f Section 416.919f Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE... studies, or an electrocardiogram. [56 FR 36965, Aug. 1, 1991] ...
20 CFR 404.1519f - Type of purchased examinations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Type of purchased examinations. 404.1519f Section 404.1519f Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... studies, or an electrocardiogram. [56 FR 36956, Aug. 1, 1991] ...
20 CFR 416.919f - Type of purchased examinations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false Type of purchased examinations. 416.919f Section 416.919f Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE... studies, or an electrocardiogram. [56 FR 36965, Aug. 1, 1991] ...
20 CFR 404.1519f - Type of purchased examinations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false Type of purchased examinations. 404.1519f Section 404.1519f Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND... studies, or an electrocardiogram. [56 FR 36956, Aug. 1, 1991] ...
20 CFR 416.919f - Type of purchased examinations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Type of purchased examinations. 416.919f Section 416.919f Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE... studies, or an electrocardiogram. [56 FR 36965, Aug. 1, 1991] ...
Reninoma presenting as cardiac syncope
Tak, Shahid I; Wani, Mohd Lateef; Khan, Khursheed A; Alai, Mohd Sultan; Shera, Altaf Hussain; Ahangar, Abdul G; Khan, Yasir Bashir; Nayeem-ul-Hassan; Irshad, Ifat
2011-01-01
Reninoma, a renin-secreting tumor of the juxta-glomerular cells of the kidney, is a rare but surgically treatable cause of secondary hypertension in children. We report a case of reninoma presenting as cardiac syncope with long QTc on electrocardiogram due to hypokalemia. PMID:21677812
The Use of a Microcomputer as an EKG Monitor.
ERIC Educational Resources Information Center
Walters, R. A.; Reynolds, R. F.
1983-01-01
Discusses the design and operation of a microcomputer system which obtains and displays an individual's electrocardiogram (EKG). The EKG information, in digital form, can be stored on a floppy disk and transmitted over telephone lines by use of a modem. (JN)
How Will I Be Monitored After Heart Surgery?
... monitor you are described below. What is an ECG? •An electrocardiogram, or ECG or EKG machine, records your heartbeat. • Tiny wires, ... normally. •A highly trained nurse will watch the ECG at all times. •You’ll be hooked up ...
Ciaccio, Edward J; Hiatt, Mark; Hegyi, Thomas; Drzewiecki, Gary M
2007-01-01
Background Monitoring of the electrocardiogram (ECG) in premature infants with conventional adhesive-backed electrodes can harm their sensitive skin. Use of an electrode belt prevents skin irritation, but the effect of belt pressure on respiratory function is unknown. A strain gauge sensor is described which measures applied belt tension. Method The device frame was comprised of an aluminum housing and slide to minimize the device weight. Velcro tabs connected housing and slide to opposite tabs located at the electrode belt ends. The slide was connected to a leaf spring, to which were bonded two piezoresistive transducers in a half-bridge circuit configuration. The device was tested for linearity and calibrated. The effect on infant respiratory function of constant belt tension in the normal range (30 g–90 g) was determined. Results The mechanical response to a step input was second order (fn = 401 Hz, ζ = 0.08). The relationship between applied tension and output voltage was linear in the range 25–225 gm of applied tension (r2 = 0.99). Measured device sensitivity was 2.18 mV/gm tension using a 5 V bridge excitation voltage. When belt tension was increased in the normal range from 30 gm to 90 gm, there was no significant change in heart rate and most respiratory functions during monitoring. At an intermediate level of tension of 50 gm, pulmonary resistance and work of breathing significantly decreased. Conclusion The mechanical and electrical design of a device for monitoring electrocardiogram electrode belt tension is described. Within the typical range of application tension, cardiovascular and respiratory function are not substantially negatively affected by electrode belt force. PMID:17445262
Takii, Eiichi; Inage, Tomohito; Yoshida, Teruhisa; Ohe, Masatsugu; Gondo, Takeki; Haraguchi, Go; Ito, Shogo; Kumanomido, Jun; Imaizumi, Tsutomu; Fukuomoto, Yoshihiro
2016-03-01
Renin-angiotensin system (RAS) inhibitors may be useful in preventing the occurrence of paroxysmal atrial fibrillation (PAF). However, evaluation of such effect is difficult because many PAF episodes are asymptomatic and not all episodes are detected by intermittent electrocardiographic monitoring. A pacemaker has been developed with dedicated functions for AF detection and electrocardiogram storage. Accordingly, we examined the effect of losartan, an angiotensin receptor blocker on PAF occurrence using this new modality. We enrolled 70 consecutive patients who had undergone dual-chamber pacemaker implantation for sick sinus syndrome. Finally, 62 patients participated in the study. Thirty patients were randomized to the losartan group (mean 43 ± 12 mg/day) and 32 patients to the control group. They were followed up for 3 months. The frequency, the maximum duration and the total duration of PAF recorded by the stored electrocardiograms for the last 1 month during the observation period and study period were compared between the two groups. The change in the frequency of PAF from the observation period in the losartan and control groups was similar (-35 ± 25 vs. -67 ± 62 times; NS). However, the change in the maximum duration and the total duration of PAF was significantly shorter in the losartan group than in the control group (-493 ± 158 vs. -10 ± 69 min; p < 0.05, and -4007 ± 2334 vs. 1119 ± 714 min; p < 0.05, respectively). Losartan suppressed the maximum duration and the total duration of PAF in patients with sick sinus syndrome without hemodynamic changes. This is the first study to show the effect of a renin-angiotensin system inhibitor on the secondary prevention of PAF using the dedicated functions of a pacemaker for PAF detection and electrocardiogram storage.
Alamrani, Mashael Hasan; Alammar, Kamila Ahmad; Alqahtani, Sarah Saad; Salem, Olfat A
2018-06-01
Critical thinking and self-confidence are imperative to success in clinical practice. Educators should use teaching strategies that will help students enhance their critical thinking and self-confidence in complex content such as electrocardiogram interpretation. Therefore, teaching electrocardiogram interpretation to students is important for nurse educators. This study compares the effect of simulation-based and traditional teaching methods on the critical thinking and self-confidence of students during electrocardiogram interpretation sessions. Thirty undergraduate nursing students volunteered to participate in this study. The participants were divided into intervention and control groups, which were taught respectively using the simulation-based and traditional teaching programs. All of the participants were asked to complete the study instrumentpretest and posttest to measure their critical thinking and self-confidence. Improvement was observed in the control and experimental groups with respect to critical thinking and self-confidence, as evidenced by the results of the paired samples t test and the Wilcoxon signed-rank test (p < .05). However, the independent t test and Mann-Whitney U test indicate that the difference between the two groups was not significant (p > .05). This study evaluated an innovative simulation-based teaching method for nurses. No significant differences in outcomes were identified between the simulator-based and traditional teaching methods, indicating that well-implemented educational programs that use either teaching method effectively promote critical thinking and self-confidence in nursing students. Nurse educators are encouraged to design educational plans with clear objectives to improve the critical thinking and self-confidence of their students. Future research should compare the effects of several teaching sessions using each method in a larger sample.
Amisulpride overdose is frequently associated with QT prolongation and torsades de pointes.
Isbister, Geoffrey K; Balit, Corrine R; Macleod, Dawson; Duffull, Stephen B
2010-08-01
This study aimed to describe the effects of the antipsychotic amisulpride in overdose, including the frequency of QT prolongation and torsades de pointes. Cases of amisulpride overdose (>1 g) were recruited from 2 state poison centers and a tertiary toxicology unit over 5 years. A 1-page clinical research form was used to collect clinical information. Copies of all electrocardiograms were obtained. Electrocardiogram parameters (QRS and QT intervals) were manually measured as previously described, and plots of QT-heart rate (HR) pairs were compared with the QT nomogram. There were 83 patients with amisulpride overdoses with a median age of 29 years (interquartile range [IQR], 23-40 years), and 42 (51%) were female. The median dose ingested was 6 g (IQR, 3-13 g, range, 1.2-120 g). The median HR was 66 beats/min (IQR, 60-81 beats/min). Bradycardia occurred in 20 cases (24%), and hypotension in 19 (23%). From 440 electrocardiograms (average of 5 per case; range, 1-15), an abnormal QT-HR pair occurred in 61 cases (73%). Torsades de pointes developed in 6 cases (7%), with doses of 4, 4.6, 18, 24, 32, and 80 g. The patient taking 32 g died after a cardiac arrest. Widened QRS did not occur except transient rate-dependent bundle-branch block in 3 cases. There were significant associations of bradycardia, hypokalemia, and hypocalcaemia, with QT prolongation and torsades de pointes. Central nervous system effects were uncommon with coma in 7 cases, seizures in 2, and dystonic reactions in 2. Amisulpride overdose commonly causes QT prolongation, bradycardia, and hypotension. Torsades de pointes occurred commonly enough to suggest that amisulpride is highly cardiotoxic in overdose.
Ciaccio, Edward J; Hiatt, Mark; Hegyi, Thomas; Drzewiecki, Gary M
2007-04-19
Monitoring of the electrocardiogram (ECG) in premature infants with conventional adhesive-backed electrodes can harm their sensitive skin. Use of an electrode belt prevents skin irritation, but the effect of belt pressure on respiratory function is unknown. A strain gauge sensor is described which measures applied belt tension. The device frame was comprised of an aluminum housing and slide to minimize the device weight. Velcro tabs connected housing and slide to opposite tabs located at the electrode belt ends. The slide was connected to a leaf spring, to which were bonded two piezoresistive transducers in a half-bridge circuit configuration. The device was tested for linearity and calibrated. The effect on infant respiratory function of constant belt tension in the normal range (30 g-90 g) was determined. The mechanical response to a step input was second order (fn = 401 Hz, zeta = 0.08). The relationship between applied tension and output voltage was linear in the range 25-225 gm of applied tension (r2 = 0.99). Measured device sensitivity was 2.18 mV/gm tension using a 5 V bridge excitation voltage. When belt tension was increased in the normal range from 30 gm to 90 gm, there was no significant change in heart rate and most respiratory functions during monitoring. At an intermediate level of tension of 50 gm, pulmonary resistance and work of breathing significantly decreased. The mechanical and electrical design of a device for monitoring electrocardiogram electrode belt tension is described. Within the typical range of application tension, cardiovascular and respiratory function are not substantially negatively affected by electrode belt force.
Shimizu, Wataru
2010-01-01
This review article sought to describe patterns of repolarization on the surface electrocardiogram in inherited cardiac arrhythmias and to discuss how the knowledge of genetic makeup and cellular data can affect the analysis based on the data derived from the experimental studies using arterially perfused canine ventricular wedge preparations. Molecular genetic studies have established a link between a number of inherited cardiac arrhythmia syndromes and mutations in genes encoding cardiac ion channels or membrane components during the past 2 decades. Twelve forms of congenital long QT syndrome have been so far identified, and genotype-phenotype correlations have been investigated especially in the 3 major genotypes-LQT1, LQT2, and LQT3. Abnormal T waves are reported in the LQT1, LQT2, and LQT3, and the differences in the time course of repolarization of the epicardial, midmyocardial, and endocardial cells give rise to voltage gradients responsible for the manifestation of phenotypic appearance of abnormal T waves. Brugada syndrome is characterized by ST-segment elevation in leads V1 to V3 and an episode of ventricular fibrillation, in which 7 genotypes have been reported. An intrinsically prominent transient outward current (I(to))-mediated action potential notch and a subsequent loss of action potential dome in the epicardium, but not in the endocardium of the right ventricular outflow tract, give rise to a transmural voltage gradient, resulting in ST-segment elevation, and a subsequent phase 2 reentry-induced ventricular fibrillation. In conclusion, transmural electrical heterogeneity of repolarization across the ventricular wall profoundly affects the phenotypic manifestation of repolarization patterns on the surface electrocardiogram in inherited cardiac arrhythmias. Copyright © 2010 Elsevier Inc. All rights reserved.
Cohen, Wayne R; Hayes-Gill, Barrie
2014-06-01
To evaluate the performance of external electronic fetal heart rate and uterine contraction monitoring according to maternal body mass index. Secondary analysis of prospective equivalence study. Three US urban teaching hospitals. Seventy-four parturients with a normal term pregnancy. The parent study assessed performance of two methods of external fetal heart rate monitoring (abdominal fetal electrocardiogram and Doppler ultrasound) and of uterine contraction monitoring (electrohystero-graphy and tocodynamometry) compared with internal monitoring with fetal scalp electrode and intrauterine pressure transducer. Reliability of external techniques was assessed by the success rate and positive percent agreement with internal methods. Bland-Altman analysis determined accuracy. We analyzed data from that study according to maternal body mass index. We assessed the relationship between body mass index and monitor performance with linear regression, using body mass index as the independent variable and measures of reliability and accuracy as dependent variables. There was no significant association between maternal body mass index and any measure of reliability or accuracy for abdominal fetal electrocardiogram. By contrast, the overall positive percent agreement for Doppler ultrasound declined (p = 0.042), and the root mean square error from the Bland-Altman analysis increased in the first stage (p = 0.029) with increasing body mass index. Uterine contraction recordings from electrohysterography and tocodynamometry showed no significant deterioration related to maternal body mass index. Accuracy and reliability of fetal heart rate monitoring using abdominal fetal electrocardiogram was unaffected by maternal obesity, whereas performance of ultrasound degraded directly with maternal size. Both electrohysterography and tocodynamometry were unperturbed by obesity. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.
Rudling, E H; Schlamowitz, S; Pipper, C B; Nilsson, E; Höllmer, M; Willesen, J L; Berendt, M; Fredholm, M; Gulløv, C H; Christiansen, M; Koch, J
2016-03-01
To investigate the prevalence and amplitudes of the electrocardiographic J wave in the Petit Basset Griffon Vendéen compared to 10 other dog breeds. Electrocardiograms from 206 healthy dogs representing 11 dog breeds were included in the study. Besides Petit Basset Griffon Vendéen (PBGV; n = 23) 10 other dog breeds were included. An electrocardiogram ruler was used for measuring the amplitudes of the J waves. The definition of a J wave was a positive deflection at the J point of ≥0.1 mV in more than 1 lead of the bipolar standard limb leads (I, II, III) or the unipolar standard limb leads (aVL and aVF). The prevalence of J waves in the PBGV (n = 23) was 91% (n = 21, standard error (SE) = 5.9%), which was significantly higher compared to seven other dog breeds (p < 0.05). The overall prevalence of J waves in all 11 dog breeds (n = 206) was 43% (n = 89, robust SE = 7.8%). There was no significant difference in the prevalence between male and female dogs (p = 0.79). Neither did age (p = 0.22) nor heart rate (p = 0.25) significantly affect the prevalence of J wave. The PBGV had the highest prevalence of J waves and the highest amplitudes compared to 10 other dog breeds. However J waves were also seen in other breeds. Therefore, J waves may be considered a normal variant on the canine electrocardiogram and should not be interpreted as cardiac disease. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Pao-Huan; Gildengers, Ariel G; Lee, Chao-Hsien; Chen, Meng-Ling; Kuo, Chian-Jue; Tsai, Shang-Ying
2015-01-01
Coronary heart disease (CHD) remains the principal cause of excessive natural deaths in bipolar patients; however, electrocardiogram analyses and clinical features predicting CHDs in elderly bipolar patients remain limited. We sought to examine the relationship between CHDs, as determined by electrocardiogram, and clinical characteristics. We recruited bipolar I outpatients Diagnostic Statistical Manual of Mental Health (DSM-IV) who were more than 60 years old and had at least one psychiatric admission. Subjects were divided into two groups based on the presence or absence of CHD diagnosed by electrocardiogram analysis at entry of study. Clinical data were obtained by a combination of interviewing patients and family members and retrospectively reviewing medical records of the most recent acute psychiatric hospitalization. Eighty patients with bipolar disorder were enrolled. A total of 20 (25%) in the study had CHDs. The mean age at the time of entry into study was 67.6 ± 5.5 years old in group with CHD and 66.8 ± 6.8 years old in that without CHD. Among the clinical characteristics examined, higher mean levels of serum sodium and thyroxine during the acute affective phase as well as more first-degree family history with bipolar disorder were related to having CHD, particularly the serum sodium level. About one fourth of old bipolar patients have CHDs in both Asian and Western populations. Aging patients with bipolar disorder may have unique clinical factors (e.g., hypernatremia or elevated thyroxine) related CHDs that could warrant special attention in their psychiatric and medical care to minimize cardiovascular disease and mortality. © The Author(s) 2015.
Alonso, Pau; Andrés, Ana; Rueda, Joaquín; Buendía, Francisco; Igual, Begoña; Rodríguez, María; Osa, Ana; Arnau, Miguel A; Salvador, Antonio
2015-05-01
Pulmonary regurgitation is a common complication in patients with repaired tetralogy of Fallot or congenital pulmonary stenosis. Electrocardiographic variables have been correlated with parameters used to evaluate right ventricular function. We aimed to analyze the diagnostic value of the width and fragmentation of the electrocardiogram in the identification of patients with right ventricular dysfunction and/or dilation. We selected 107 consecutive patients diagnosed with severe pulmonary insufficiency after repair of pulmonary stenosis or tetralogy of Fallot. The tests included electrocardiography, echocardiography, and magnetic resonance. Each electrocardiogram was analyzed manually to measure QRS duration. We defined QRS fragmentation as the presence of low-voltage waves in the terminal portion of the QRS complex in at least 2 contiguous leads. We found a significant negative correlation between QRS width and right ventricular function, as well as a positive correlation with right ventricular volume. The receiver operating characteristic curve indicated a cut-off point for QRS width of 140ms, which showed good sensitivity for a diagnosis of right ventricular dilation (> 80%) and dysfunction (> 95%). In logistic regression models, a QRS duration > 140ms was found to be the only independent predictor of right ventricular dilation and dysfunction. Electrocardiography is a rapid, widely available, and reproducible tool. QRS width constitutes an independent predictor of the presence of right ventricular dilation and dysfunction. This study is the first to provide a cutoff value for QRS width to screen for right ventricle involvement. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Lobo, T; Morgan, J; Bjorksten, A; Nicholls, K; Grigg, L; Centra, E; Becker, G
2008-06-01
The aim of this study was to document exercise capacity and serial electrocardiogram and echocardiograph findings in a cohort of Australian patients with Fabry disease, in relation to their history of enzyme replacement therapy (ERT). Fabry disease has multifactorial effects on the cardiovascular system. Most previous studies have focused on electrocardiographic and echocardiographic parameters. Exercise capacity can be used as an integrated measure of cardiovascular function and allows the effects of treatment to be monitored. A total of 38 patients (30 men and 8 women) with Fabry disease were monitored by 12-lead electrocardiograms every 6-12 months, and by annual standardized-protocol echocardiograms. Bicycle stress tests with VO(2) max measurement and once-only 6 minutes' walk tests were also carried out in subsets of patients whose general health status allowed testing. Seventy per cent of patients met electrocardiogram criteria for left ventricular hypertrophy. Left ventricular hypertrophy on echocardiograph was present in 64% of patients (80% of men). Exercise capacity was reduced in patients with Fabry disease compared with that predicted from normative population data. Mild improvement in anaerobic threshold was seen in the first year of ERT (14.1 +/- 3.0 to 15.8 +/- 3.0, P = 0.02), but no consistent further increase was seen beyond the first year. Most patients had resting bradycardia, with impaired ability to increase heart rate during exercise. Serial testing on ERT showed an improvement in anaerobic threshold but no significant change in VO(2) max. Male patients with Fabry disease were unable to attain predicted maximal heart rate on exercise or to achieve normal exercise levels. ERT was associated with a small improvement in anaerobic threshold over the first year.
Lin, Eric; Craig, Calvin; Lamothe, Marcel; Sarunic, Marinko V.; Beg, Mirza Faisal
2015-01-01
Zebrafish are increasingly being used as a model of vertebrate cardiology due to mammalian-like cardiac properties in many respects. The size and fecundity of zebrafish make them suitable for large-scale genetic and pharmacological screening. In larger mammalian hearts, optical mapping is often used to investigate the interplay between voltage and calcium dynamics and to investigate their respective roles in arrhythmogenesis. This report outlines the construction of an optical mapping system for use with zebrafish hearts, using the voltage-sensitive dye RH 237 and the calcium indicator dye Rhod-2 using two industrial-level CCD cameras. With the use of economical cameras and a common 532-nm diode laser for excitation, the rate dependence of voltage and calcium dynamics within the atrial and ventricular compartments can be simultaneously determined. At 140 beats/min, the atrial action potential duration was 36 ms and the transient duration was 53 ms. With the use of a programmable electrical stimulator, a shallow rate dependence of 3 and 4 ms per 100 beats/min was observed, respectively. In the ventricle the action potential duration was 109 ms and the transient duration was 124 ms, with a steeper rate dependence of 12 and 16 ms per 100 beats/min. Synchronous electrocardiograms and optical mapping recordings were recorded, in which the P-wave aligns with the atrial voltage peak and R-wave aligns with the ventricular peak. A simple optical pathway and imaging chamber are detailed along with schematics for the in-house construction of the electrocardiogram amplifier and electrical stimulator. Laboratory procedures necessary for zebrafish heart isolation, cannulation, and loading are also presented. PMID:25740339
Terho, Henri K; Tikkanen, Jani T; Kenttä, Tuomas V; Junttila, M Juhani; Aro, Aapo L; Anttonen, Olli; Kerola, Tuomas; Rissanen, Harri A; Knekt, Paul; Reunanen, Antti; Huikuri, Heikki V
2016-11-01
The long-term prognostic value of a standard 12-lead electrocardiogram (ECG) for predicting cardiac events in apparently healthy middle-aged subjects is not well defined. A total of 9511 middle-aged subjects (mean age 43 ± 8.2 years, 52% males) without a known cardiac disease and with a follow-up 40 years were included in the study. Fatal and non-fatal cardiac events were collected from the national registries. The predictive value of ECG was separately analyzed for 10 and 30 years. Major ECG abnormalities were classified according to the Minnesota code. Subjects with major ECG abnormalities (N = 1131) had an increased risk of cardiac death after 10-years (adjusted hazard ratio [HR] 1.7; 95% confidence interval [95% CI], 1.1-2.5, p = 0.009) and 30-years of follow-up (HR 1.3, 95% CI, 1.1-1.5, p < 0.001). Model discrimination measured with the C-index showed only a minor improvement with the inclusion of ECG abnormalities: 0.851 versus 0.853 and 0.742 versus 0.743 for 10- and 30-year follow-up, respectively. ECG did not predict non-fatal cardiac events after 10-years or 30-years of follow-up. Major ECG abnormalities are associated with an increased risk of short and long-term cardiac mortality in middle-aged subjects. However, the improvement in discrimination between subjects with and without fatal cardiac events was marginal with abnormal ECG. Abnormalities observed on 12-lead electrocardiogram are shown to have prognostic significance for cardiac events in elderly subjects without known cardiac disease. Our results suggest that ECG abnormalities increase the risk of fatal cardiac events also in middle-aged healthy subjects.
Chen, Jan-Yow; Lin, Kuo-Hung; Chang, Kuan-Cheng; Chou, Che-Yi
2017-08-03
QRS duration has been associated with the response to cardiac resynchronization therapy (CRT). However, the methods for defining QRS duration to predict the outcome of CRT have discrepancies in previous reports. The aim of this study was to determine an optimal measurement of QRS duration to predict the response to CRT.Sixty-one patients who received CRT were analyzed. All patients had class III-IV heart failure, left ventricular ejection fraction not more than 35%, and complete left bundle branch block. The shortest, longest, and average QRS durations from the 12 leads of each electrocardiogram (ECG) were measured. The responses to CRT were determined using the changes in echocardiography after 6 months. Thirty-five (57.4%) patients were responders and 26 (42.6%) patients were non-responders. The pre-procedure shortest, average, and longest QRS durations and the QRS shortening (ΔQRS) of the shortest QRS duration were significantly associated with the response to CRT in a univariate logistic regression analysis (P = 0.002, P = 0.03, P = 0.04 and P = 0.04, respectively). Based on the measurement of the area under curve of the receiver operating characteristic curve, only the pre-procedure shortest QRS duration and the ΔQRS of the shortest QRS duration showed significant discrimination for the response to CRT (P = 0.002 and P = 0.038, respectively). Multivariable logistic regression showed the pre-procedure shortest QRS duration is an independent predictor for the response to CRT.The shortest QRS duration from the 12 leads of the electrocardiogram might be an optimal measurement to predict the response to CRT.
Pogach, Melanie S.; Punjabi, Naresh M.; Thomas, Neil; Thomas, Robert J.
2012-01-01
Study Objectives: Sleep disordered breathing (SDB) is independently associated with insulin resistance, glucose intolerance, and type 2 diabetes mellitus. Experimental sleep fragmentation has been shown to impair insulin sensitivity. Conventional electroencephalogram (EEG)-based sleep-quality measures have been inconsistently associated with indices of glucose metabolism. This analysis explored associations between glucose metabolism and an EEG-independent measure of sleep quality, the sleep spectrogram, which maps coupled oscillations of heart-rate variability and electrocardiogram (ECG)-derived respiration. The method allows improved characterization of the quality of stage 2 non-rapid eye movement (NREM) sleep. Design: Cross-sectional study. Setting: N/A. Participants: Nondiabetic subjects with and without SDB (n = 118) underwent the frequently sampled intravenous glucose tolerance test (FSIVGTT) and a full-montage polysomnogram. The sleep spectrogram was generated from ECG collected during polysomnography. Interventions: N/A. Measurements and Results: Standard polysomnographic stages (stages 1, 2, 3+4, and rapid eye movement [REM]) were not associated with the disposition index (DI) derived from the FSIVGTT. In contrast, spectrographic high-frequency coupling (a marker of stable or “effective” sleep) duration was associated with increased, and very-low-frequency coupling (a marker of wake/REM/transitions) associated with reduced DI. This relationship was noted after adjusting for age, sex, body mass index, slow wave sleep, total sleep time, stage 1, the arousal index, and the apnea-hypopnea index. Conclusions: ECG-derived sleep-spectrogram measures of sleep quality are associated with alterations in glucose-insulin homeostasis. This alternate mode of estimating sleep quality could improve our understanding of sleep and sleep-breathing effects on glucose metabolism. Citation: Pogach MS; Punjabi NM; Thomas N; Thomas RJ. Electrocardiogram-based sleep spectrogram measures of sleep stability and glucose disposal in sleep disordered breathing. SLEEP 2012;35(1):139-148. PMID:22215928
Suitable Adaptation Mechanisms for Intelligent Tutoring Technologies
2010-12-01
the Acoustic Society of America, 93(2), pp. 1097-1108. Neurofeedback equipment - Wireless Brainquiry PET EEG and ActivEEG. (n.d.). Retrieved from...27 5.2 Electroencephalogram ( EEG ...electroencephalogram ( EEG ), heart rate variability (HRV- a measure involving the electrocardiogram [ECG]), and galvanic skin response (GSR) either
Human Characteristics and Measures in Systems Design
2003-01-01
Electrodermal Skin conductance Field/lab $ * activity and electrode response EKG/ECG Electrocardiogram ECG electrodes- Field/la:h $ * HR, HRV Heart rate...illumination, motion, etc.). It may also be caused by psychological pressures (e.g., anxiety , anger/hostility, the "fight or flight" syndrome, threat
ERIC Educational Resources Information Center
Kingston, Michael E.
1979-01-01
Instruction in electrocardiogram interpretation was provided for students at the University of Calgary by distributing complete cardiograms to them at the beginning of the week, for nine weeks, followed by analysis by an instructor at the end of the week. Skill development, reinforcement, course evaluation, and student satisfaction are described.
Nabeshima, Yuji; Kimura, Yoshitaka; Ito, Takuro; Ohwada, Kazunari; Karashima, Akihiro; Katayama, Norihiro; Nakao, Mitsuyuki
2013-01-01
Fetal electrocardiogram (fECG) and its vector form (fVECG) could provide significant clinical information concerning physiological conditions of a fetus. So far various independent component analysis (ICA)-based methods for extracting fECG from maternal abdominal signals have been proposed. Because full extraction of component waves such as P, Q, R, S, and T, is difficult to be realized under noisy and nonstationary situations, the fVECG is further hard to be reconstructed, where different projections of the fetal heart vector are required. In order to reconstruct fVECG, we proposed a novel method for synthesizing different projections of the heart vector, making good use of the fetus movement. This method consists of ICA, estimation of rotation angles of fetus, and synthesis of projections of the heart vector. Through applications to the synthetic and actual data, our method is shown to precisely estimate rotation angle of the fetus and to successfully reconstruct the fVECG.
Evaluation of thallium-201 scanning for detection of latent coronary artery disease
NASA Technical Reports Server (NTRS)
Johnson, P. C.; Leblanc, A.; Deboer, L.; Jhingran, S.
1978-01-01
The use of thallium imaging as a noninvasive method to accurately screen shuttle passengers for latent coronary artery disease was investigated. All radionuclide procedures were performed using an Anger type camera with a high resolution collimator. A minimum of 200,000 counts were collected for each image using a 20% window centered on the 69-83 keV X-rays. For the images obtained following injection with the patient at rest, the testing was begun 10 minutes after injection. Injections of TT during exercise were made at a point near the termination of the treadmill procedure as determined by either the appearance of ST segment changes on the electrocardiogram consistant with subendocardial ischemia, the appearance of angina-like chest pain in the patient or fatigue in the patient which required cessation of the test. The severity of heart disease was based on the medical history, physical exam, exercise electrocardiograms, chest X-rays and the coronary arteriogram.
[Limits of cardiac functional adaptation in "top level" resistance athletes].
Carù, B; Righetti, G; Bossi, M; Gerosa, C; Gazzotti, G; Maranetto, D
2001-02-01
Sports activity, particularly when performed at high level, provokes cardiovascular adjustments depending on the type of sport and on the level of the load. We evaluated 15 athletes from the Italian national team during a non-agonistic period of cross country skiing, with non-invasive tests including exercise test, color Doppler echocardiography, Holter monitoring, physical examination and standard rest electrocardiogram. Physical examination, rest electrocardiogram, exercise testing and echocardiography were all within the range of the expected values for this type of subjects. Holter monitoring recorded during the periods of agonistic activity revealed significant hypokinetic arrhythmias such as severe bradycardia, pauses, I and II degree atrioventricular blocks, and complete atrioventricular block in 2 cases; these features were not observed on Holter monitoring recorded during the non-agonistic period. The perfect health status of subjects and their racing results may bring about physiological functional adjustments, but these observations suggest the need for a follow-up to evaluate possible pathologic outcomes.
Energy and Quality Evaluation for Compressive Sensing of Fetal Electrocardiogram Signals
Da Poian, Giulia; Brandalise, Denis; Bernardini, Riccardo; Rinaldo, Roberto
2016-01-01
This manuscript addresses the problem of non-invasive fetal Electrocardiogram (ECG) signal acquisition with low power/low complexity sensors. A sensor architecture using the Compressive Sensing (CS) paradigm is compared to a standard compression scheme using wavelets in terms of energy consumption vs. reconstruction quality, and, more importantly, vs. performance of fetal heart beat detection in the reconstructed signals. We show in this paper that a CS scheme based on reconstruction with an over-complete dictionary has similar reconstruction quality to one based on wavelet compression. We also consider, as a more important figure of merit, the accuracy of fetal beat detection after reconstruction as a function of the sensor power consumption. Experimental results with an actual implementation in a commercial device show that CS allows significant reduction of energy consumption in the sensor node, and that the detection performance is comparable to that obtained from original signals for compression ratios up to about 75%. PMID:28025510
Patra, Kamakshya P; Sankararaman, Senthilkumar; Jackson, Robert; Hussain, Sunny Z
2012-09-01
Amitriptyline (AMT) is commonly used in the management of children with irritable bowel syndrome. AMT is pro-arrhythmogenic and increases the risk of sudden cardiac death. However, there is not enough data regarding the cardiac toxicity in therapeutic doses of AMT in children and the need for screening electrocardiogram (EKG). Errors in computer EKG interpretation are not uncommon. In a risk-prevention study, the authors sought to identify the true incidence of prolonged corrected QT (QTc) interval and other arrhythmias in children with irritable bowel syndrome before the initiation of AMT. Out of the 760 EKGs screened, 3 EKGs demonstrated a true prolonged QTc after the careful manual reading by a pediatric cardiologist and they were not picked by computer-generated reading. The authors conclude that screening EKG should always be performed on children before initiating AMT therapy. Also, the computer-generated EKG needs to be verified by a pediatric cardiologist to avoid serious misinterpretations.
Bowman, Natalie M.; Kawai, Vivian; Gilman, Robert H.; Bocangel, Cesar; Galdos-Cardenas, Gerson; Cabrera, Lilia; Levy, Michael Z.; Cornejo del Carpio, Juan Geny; Delgado, Freddy; Rosenthal, Lauren; Pinedo-Cancino, Vivian V.; Steurer, Francis; Seitz, Amy E.; Maguire, James H.; Bern, Caryn
2011-01-01
Chagas disease affects an estimated 8 million people in Latin America. Infected individuals have 20–30% lifetime risk of developing cardiomyopathy, but more subtle changes in autonomic responses may be more frequent. We conducted a matched case-control study of children in Arequipa, Peru, where triatomine infestation and Trypanosoma cruzi infection are emerging problems. We collected data on home environment, history, physical examination, electrocardiogram, and autonomic testing. Signs of triatomine infestation and/or animals sleeping in the child's room and household members with Chagas disease were associated with increased infection risk. Electrocardiogram findings did not differ between cases and controls. However, compared with control children, infected children had blunted autonomic responses by three different measures, the Valsalva maneuver, the cold pressor test, and the orthostatic test. T. cruzi-infected children show autonomic dysfunction, although the prognostic value of this finding is not clear. Sustained vector control programs are essential to decreasing future T. cruzi infections. PMID:21212207
DeBonis, Katrina; Blair, Thomas R; Payne, Samuel T; Wigan, Katherine; Kim, Sara
2015-12-01
Web-based instruction in post-graduate psychiatry training has shown comparable effectiveness to in-person instruction, but few topics have been addressed in this format. This study sought to evaluate the viability of a web-based curriculum in teaching electrocardiogram (EKG) reading skills to psychiatry residents. Interest in receiving educational materials in this format was also assessed. A web-based curriculum of 41 slides, including eight pre-test and eight post-test questions with emphasis on cardiac complications of psychotropic medications, was made available to all psychiatry residents via email. Out of 57 residents, 30 initiated and 22 completed the module. Mean improvement from pre-test to post-test was 25 %, and all 22 completing participants indicated interest in future web-based instruction. This pilot study suggests that web-based instruction is feasible and under-utilized as a means of teaching psychiatry residents. Potential uses of web-based instruction, such as tracking learning outcomes or patient care longitudinally, are also discussed.
NASA Astrophysics Data System (ADS)
Yu, Huidan (Whitney); Chen, Xi; Chen, Rou; Wang, Zhiqiang; Lin, Chen; Kralik, Stephen; Zhao, Ye
2015-11-01
In this work, we demonstrate the validity of 4-D patient-specific computational hemodynamics (PSCH) based on 3-D time-of-flight (TOF) MR angiography (MRA) and 2-D electrocardiogram (ECG) gated phase contrast (PC) images. The mesoscale lattice Boltzmann method (LBM) is employed to segment morphological arterial geometry from TOF MRA, to extract velocity profiles from ECG PC images, and to simulate fluid dynamics on a unified GPU accelerated computational platform. Two healthy volunteers are recruited to participate in the study. For each volunteer, a 3-D high resolution TOF MRA image and 10 2-D ECG gated PC images are acquired to provide the morphological geometry and the time-varying flow velocity profiles for necessary inputs of the PSCH. Validation results will be presented through comparisons of LBM vs. 4D Flow Software for flow rates and LBM simulation vs. MRA measurement for blood flow velocity maps. Indiana University Health (IUH) Values Fund.
De Gennaro, Luisa; Brunetti, Natale Daniele; Ruggiero, Massimo; Rutigliano, David; Locuratolo, Nicola; Di Biase, Matteo; Caldarola, Pasquale
2017-10-01
Right coronary artery (RCA) occlusion in inferior acute myocardial infarction is usually heralded by ST-elevation both in inferior and in right precordial leads. We report the case of a 68-year-old male, who presented marked ST-elevation in inferior leads, mirrored by ST-depression in anterior-septal and lateral leads. Right precordial lead electrocardiogram unexpectedly showed ST-depression V1R-V5R leads. Coronary angiography showed mid-left anterior descending (LAD) coronary near-complete occlusion with distal wrapping LAD. Left circumflex artery was not occluded, while RCA was occluded mid tract. The patient was treated with coronary angioplasty on RCA and LAD. Absence of ST-elevation in right precordial leads may be presumably explained by the presence of a large ischemic area distal to mid-LAD near-occlusive stenosis and of a long-wrapping LAD. Complex coronary anatomy and intertwined ischemic areas may underlie apparently discording electrocardiograms.
Nerve conduction studies are safe in patients with central venous catheters.
London, Zachary N; Mundwiler, Andrew; Oral, Hakan; Gallagher, Gary W
2017-08-01
It is unknown if central venous catheters bypass the skin's electrical resistance and engender a risk of nerve conduction study-induced cardiac arrhythmia. The objective of this study is to determine if nerve conduction studies affect cardiac conduction and rhythm in patients with central venous catheters. Under continuous 12-lead electrocardiogram monitoring, subjects with and without central venous catheters underwent a series of upper extremity nerve conduction studies. A cardiologist reviewed the electrocardiogram tracings for evidence of cardiac conduction abnormality or arrhythmia. Ten control subjects and 10 subjects with central venous catheters underwent the nerve conduction study protocol. No malignant arrhythmias or conduction abnormalities were noted in either group. Nerve conduction studies of the upper extremities, including both proximal stimulation and repetitive stimulation, do not appear to confer increased risk of cardiac conduction abnormality in those patients with central venous catheters who are not critically ill or have a prior history of arrhythmia. Muscle Nerve 56: 321-323, 2017. © 2016 Wiley Periodicals, Inc.
Guillem, M Salud; Sahakian, Alan V; Swiryn, Steven
2008-01-01
The objective of this study was the evaluation of the accuracy of Dower inverse transform for the derivation of the P wave in orthogonal leads. We tested the accuracy of Dower transform on the P wave and compared it with a P-wave-optimized transform in a database of 123 simultaneous recordings of electrocardiograms and vectorcardiograms. This new transform achieved a lower error when we compared derived vs true measured P waves (mean +/- SD, 12.2 +/- 8.0 VRMS) than Dower transform (14.4 +/- 9.5 Root mean squared voltage) and higher correlation values (Rx, 0.93 +/- 0.12; Ry, 0.90 +/- 0.27; Rz, 0.91 +/- 0.18; vs Dower: Rx, 0.88 +/- 0.15; Ry, 0.91 +/- 0.26; Rz, 0.85 +/- 0.23). We conclude that derivation of orthogonal leads for the P wave can be improved by using an atrial-based transform matrix.
Use of Electrocardiogram as Part of the Preparticipation Examination.
Chain, Kelly; Gregory, Andrew
2016-01-01
A sudden cardiac event or death in a young athlete is a traumatic and memorable event. These tragic events have long-lasting and widespread influences that not only affect the person's immediate family, but also have profound effects on the team, school, and entire community. Over the past several decades there has been a significant research effort in the area of sudden cardiac death (SCD) in athletes in hopes of decreasing preventable deaths. One area of research and discussion that has emerged is the use of electrocardiograms (EKGs) in preparticipation screening examinations as a tool to help identify athletes at risk for SCD. The use of an EKG in addition to a detailed history and physical examination is a controversial and frequently debated topic. To help sort through some of the controversy, this article discusses some of the pros and cons of incorporating the EKG as a screening modality in the preparticipation evaluation for clearance to participate in sports. Copyright 2016, SLACK Incorporated.
A portable monitor system for biology signal based on singlechip
NASA Astrophysics Data System (ADS)
Tu, Qiaoling; Guo, Jianhua; He, Li; Xu, Xia
2005-12-01
The objectives of the paper are to improve accuracy of the electrocardiogram and temperature signal, improve the system stability and the capability of dynamic response, and decrease power consumption and volume of the system. The basic method is making use of the inner resource of the singlechip, such as the exact constant-current source, hardware multiplier, ADC, etc. The model of singlechip is MSP430F449 of TI (Texas Instruments). A simple integral-coefficient band-rejection digital filter was designed for analyzing the electrocardiogram signal. The deviation of temperature coming from the degradation of battery voltage was compensated for. An automatic discharge access was designed in the circuit to improve the capability of dynamic response of circuit. The results indicate that the 50 Hz power frequency interfering and the baseline drift are filtered, the figure is clear, the accuracy of temperature is 0.03°C, and the consumption current is less than 1.3mA. The system can meet the requirement in ward monitor and surgery monitor.
de Chazal, Philip; Heneghan, Conor; Sheridan, Elaine; Reilly, Richard; Nolan, Philip; O'Malley, Mark
2003-06-01
A method for the automatic processing of the electrocardiogram (ECG) for the detection of obstructive apnoea is presented. The method screens nighttime single-lead ECG recordings for the presence of major sleep apnoea and provides a minute-by-minute analysis of disordered breathing. A large independently validated database of 70 ECG recordings acquired from normal subjects and subjects with obstructive and mixed sleep apnoea, each of approximately eight hours in duration, was used throughout the study. Thirty-five of these recordings were used for training and 35 retained for independent testing. A wide variety of features based on heartbeat intervals and an ECG-derived respiratory signal were considered. Classifiers based on linear and quadratic discriminants were compared. Feature selection and regularization of classifier parameters were used to optimize classifier performance. Results show that the normal recordings could be separated from the apnoea recordings with a 100% success rate and a minute-by-minute classification accuracy of over 90% is achievable.
Cripps, T; Bennett, E D; Camm, A J; Ward, D E
1988-01-01
The value of the high gain, signal averaged electrocardiogram combined with 24 hour electrocardiographic monitoring in the prediction of arrhythmic events was assessed in 159 patients in the first week after myocardial infarction. Eleven patients (7%) suffered arrhythmic events during a mean (SD) of 12 (6) months of follow up (range 2-22, median 13 months). The combination of high gain, signal averaged electrocardiography and 24 hour electrocardiographic monitoring was more accurate than either technique alone or than clinical information collected during admission in predicting these events. The combination identified a high risk group of 13 (8%) patients, with an arrhythmic event rate of 62% and a low risk group with an event rate of 2%. The combination of high gain, signal averaged electrocardiography and 24 hour electrocardiographic monitoring in the first week after myocardial infarction provides a rapid, cheap, and non-invasive bedside method for the prediction of arrhythmias. PMID:3179133
Utility of the exercise electrocardiogram testing in sudden cardiac death risk stratification.
Refaat, Marwan M; Hotait, Mostafa; Tseng, Zian H
2014-07-01
Sudden cardiac death (SCD) remains a major public health problem. Current established criteria identifying those at risk of sudden arrhythmic death, and likely to benefit from implantable cardioverter defibrillators (ICDs), are neither sensitive nor specific. Exercise electrocardiogram (ECG) testing was traditionally used for information concerning patients' symptoms, exercise capacity, cardiovascular function, myocardial ischemia detection, and hemodynamic responses during activity in patients with hypertrophic cardiomyopathy. We conducted a systematic review of MEDLINE on the utility of exercise ECG testing in SCD risk stratification. Exercise testing can unmask suspected primary electrical diseases in certain patients (catecholaminergic polymorphic ventricular tachycardia or concealed long QT syndrome) and can be effectively utilized to risk stratify patients at an increased (such as early repolarization syndrome and Brugada syndrome) or decreased risk of SCD, such as the loss of preexcitation on exercise testing in asymptomatic Wolff-Parkinson-White syndrome. Exercise ECG testing helps in SCD risk stratification in patients with and without arrhythmogenic hereditary syndromes. © 2014 Wiley Periodicals, Inc.
The electrocardiogram signal of Seba's short-tailed bat, Carollia perspicillata.
Mihova, Diana; Hechavarría, Julio C
2016-07-01
A number of studies have successfully used electrocardiogram (ECG) signals to characterize complex physiological phenomena such as associative learning in bats. However, at present, no thorough characterization of the structure of ECG signals is available for these animals. The aim of the present study was to quantitatively characterize features of the ECG signals in the bat species Carollia perspicillata, a species that is commonly used in neuroethology studies. Our results show that the ECG signals of C. perspicillata follow the typical mammalian pattern, in that they are composed by a P wave, QRS complex and a T wave. Peak-to-peak amplitudes in the bats' ECG signals were larger in measuring configurations in which one of the electrodes was attached to the right thumb. In addition, large differences in the instantaneous heart rate (HR) distributions were observed between ketamine/xylazine anesthetized and awake bats. Ketamine/xylazine might target the neural circuits that control HR, therefore, instantaneous HR measurements should only be used as physiological marker in awake animals.
Mobile messaging services-based personal electrocardiogram monitoring system.
Tahat, Ashraf A
2009-01-01
A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.
Mobile Messaging Services-Based Personal Electrocardiogram Monitoring System
Tahat, Ashraf A.
2009-01-01
A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services. PMID:19707531
A PDA-based electrocardiogram/blood pressure telemonitor for telemedicine.
Bolanos, Marcos; Nazeran, Homayoun; Gonzalez, Izzac; Parra, Ricardo; Martinez, Christopher
2004-01-01
An electrocardiogram (ECG) / blood pressure (BP) telemonitor consisting of comprehensive integration of various electrical engineering concepts, devices, and methods was developed. This personal digital assistant-based (PDAbased) system focused on integration of biopotential amplifiers, photoplethysmographic measurement of blood pressure, microcontroller devices, programming methods, wireless transmission, signal filtering and analysis, interfacing, and long term memory devices (24 hours) to develop a state-of-the-art ECG/BP telemonitor. These instrumentation modules were developed and tested to realize a complete and compact system that could be deployed to assist in telemedicine applications and heart rate variability studies. The specific objective of this device was to facilitate the long term monitoring and recording of ECG and blood pressure signals. This device was able to acquire ECG/BP waveforms, transmit them wirelessly to a PDA, save them onto a compact flash memory, and display them on the LCD screen of the PDA. It was also capable of calculating the heart rate (HR) in beats per minute, and providing systolic and diastolic blood pressure values.
NASA Technical Reports Server (NTRS)
Tragardh, Elin; Schlegel, Todd T.; Carlsson, Marcus; Pettersson, Jonas; Nilsson, Klas; Pahlm, Olle
2007-01-01
Background: A previous study has shown that analysis of high-frequency QRS components (HF-QRS) is highly sensitive and reasonably specific for detecting reversible perfusion defects on myocardial perfusion imaging (MPI) scans during adenosine. The purpose of the present study was to try to reproduce those findings. Methods: 12-lead high-resolution electrocardiogram recordings were obtained from 100 patients before (baseline) and during adenosine Tc-99m-tetrofosmin MPI tests. HF-QRS were analyzed regarding morphology and changes in root mean square (RMS) voltages from before the adenosine infusion to peak infusion. Results: The best area under the curve (AUC) was found in supine patients (AUC=0.736) in a combination of morphology and RMS changes. None of the measurements, however, were statistically better than tossing a coin (AUC=0.5). Conclusion: Analysis of HF-QRS was not significantly better than tossing a coin for determining reversible perfusion defects on MPI scans.
Evaluation of Dry Electrodes in Canine Heart Rate Monitoring.
Virtanen, Juhani; Somppi, Sanni; Törnqvist, Heini; Jeyhani, Vala; Fiedler, Patrique; Gizatdinova, Yulia; Majaranta, Päivi; Väätäjä, Heli; Valldeoriola Cardó, Anna; Lekkala, Jukka; Tuukkanen, Sampo; Surakka, Veikko; Vainio, Outi; Vehkaoja, Antti
2018-05-30
The functionality of three dry electrocardiogram electrode constructions was evaluated by measuring canine heart rate during four different behaviors: Standing, sitting, lying and walking. The testing was repeated (n = 9) in each of the 36 scenarios with three dogs. Two of the electrodes were constructed with spring-loaded test pins while the third electrode was a molded polymer electrode with Ag/AgCl coating. During the measurement, a specifically designed harness was used to attach the electrodes to the dogs. The performance of the electrodes was evaluated and compared in terms of heartbeat detection coverage. The effect on the respective heart rate coverage was studied by computing the heart rate coverage from the measured electrocardiogram signal using a pattern-matching algorithm to extract the R-peaks and further the beat-to-beat heart rate. The results show that the overall coverage ratios regarding the electrodes varied between 45⁻95% in four different activity modes. The lowest coverage was for lying and walking and the highest was for standing and sitting.
Human Age Recognition by Electrocardiogram Signal Based on Artificial Neural Network
NASA Astrophysics Data System (ADS)
Dasgupta, Hirak
2016-12-01
The objective of this work is to make a neural network function approximation model to detect human age from the electrocardiogram (ECG) signal. The input vectors of the neural network are the Katz fractal dimension of the ECG signal, frequencies in the QRS complex, male or female (represented by numeric constant) and the average of successive R-R peak distance of a particular ECG signal. The QRS complex has been detected by short time Fourier transform algorithm. The successive R peak has been detected by, first cutting the signal into periods by auto-correlation method and then finding the absolute of the highest point in each period. The neural network used in this problem consists of two layers, with Sigmoid neuron in the input and linear neuron in the output layer. The result shows the mean of errors as -0.49, 1.03, 0.79 years and the standard deviation of errors as 1.81, 1.77, 2.70 years during training, cross validation and testing with unknown data sets, respectively.
Tan, Robin; Perkowski, Marek
2017-01-01
Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject verification accuracy, better than the 98.33% accuracy from random forest alone and 96.31% accuracy from wavelet distance measure algorithm alone. These results demonstrate the superiority of the proposed algorithm for biometric identification, hence supporting its practicality in areas such as cloud data security, cyber-security or remote healthcare systems. PMID:28230745
Tan, Robin; Perkowski, Marek
2017-02-20
Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject verification accuracy, better than the 98.33% accuracy from random forest alone and 96.31% accuracy from wavelet distance measure algorithm alone. These results demonstrate the superiority of the proposed algorithm for biometric identification, hence supporting its practicality in areas such as cloud data security, cyber-security or remote healthcare systems.
Panduranga, Prashanth; Al-Farqani, Abdullah; Al-Rawahi, Najib
2012-11-01
A 10-year-old girl presented to the emergency department of a regional hospital with 1 episode of generalized tonic-clonic seizures. Postictal monitoring followed by a 12-lead electrocardiogram showed fast atrial fibrillation with intermittent wide QRS regular tachycardia. Immediately following this, her rhythm changed to wide QRS irregular tachycardia without hemodynamic compromise. She was suspected to have ventricular tachycardia and was treated with intravenous amiodarone with cardioversion to sinus rhythm. Subsequent electrocardiogram in sinus rhythm showed typical features of manifest Wolff-Parkinson-White (WPW) accessory pathway. This case illustrates the diagnostic and therapeutic dilemmas in patients with atrial fibrillation, wide QRS tachycardia, and undiagnosed WPW syndrome with antidromic conduction of atrial arrhythmias through the accessory pathway. Furthermore, this case demonstrates that undiagnosed wide QRS tachycardias need to be treated with drugs acting on the accessory pathway, thus keeping in mind underlying WPW syndrome as a possibility to avoid potentially catastrophic events.
Basic Interpretation of EKG's. N203.
ERIC Educational Resources Information Center
Hall, Laura T.
A description is provided of an associate degree in nursing science course, "Rapid Interpretation of Electrocardiograms (EKG's)," designed to emphasize the nurse's role in the interpretation of the basic EKG and the medical interventions necessary to treat arrythmias. The first section of the course description provides information on…
DOT National Transportation Integrated Search
1974-05-01
A resting 'normal' ECG can coexist with known angina pectoris, positive angiocardiography and previous myocardial infarction. In contemporary exercise ECG tests, a false positive/false negative total error of 10% is not unusual. Research aimed at imp...
Epidemiological studies have linked air pollution exposure to adverse respiratory health effects, especially in individuals with inflammatory airways disease. Symptomatic asthmatics appear to be at greatest risk. We previously demonstrated that exposure of rats to particulate...
Getting a Jump on the Science Fair.
ERIC Educational Resources Information Center
Fort, Deborah C.
1985-01-01
Success of the Murch Elementary School (Washington, DC) science fair is due to many factors which are applicable to other schools. Suggestions, ideas, and hints are given in this description of the school's program. Projects with an electrocardiogram, water weeds, and preserving ice are also discussed. (DH)
Heart Rates of Elite Synchronized Swimmers.
ERIC Educational Resources Information Center
Gemma, Karen Erickson; Wells, Christine L.
1987-01-01
Heart rates were recorded by radiotelemetry in ten elite and national-class synchronized swimmers as they performed competitive figures of high degrees of difficulty. The focus was on changes in heart rates and electrocardiogram patterns for each body position, especially those requiring facial immersion and breath-holding. (Author/MT)
NASA Technical Reports Server (NTRS)
Anderson, R. E.; Carlson, A. W.; Lewis, J.
1977-01-01
Helical VHF antenna mounts on roof of moving vehicle to communicate with distant stations via earth satellites. Antenna requires no pointing and can provide two-way communication while vehicle moves at high speed. Device has proved extremely successful in electrocardiogram transmission tests between medical services vehicle and hospital emergency room.
Implanted telemeter for electrocardiogram and body temperature
NASA Technical Reports Server (NTRS)
Barrows, W. F.
1972-01-01
Measuring system requiring one blocking oscillator to generate modulated pulse repetition rate is implantable in the bodies of small animals. Device has life of two years and transmission range of about three feet. EKG sensing unit also is used to sense electromyogram or electrooculogram of laboratory animals.
Biotelemetry system for ambulatory patients
NASA Technical Reports Server (NTRS)
Fryer, T. B.
1978-01-01
Compact transmitter for multichannel telemetry of medical data is carried in patient's belt. Pulse-code modulation (PCM), is used for high-quality signal, and low-power CMOS integrated circuits make miniaturization possible. Transmitter is useful for electro-encephalograms (EEG) and electro-cardiograms (EKG) and other biomedical patient-monitoring situations.
The Utility of the Small Rodent Electrocardiogram in Toxicology
Extensive research has lead to a growing appreciation that the heart is acutely sensitive to a broad array of toxicants via multiple routes of exposure. These agents are as diverse as the anti-neoplastic drug doxorubicin and various components of ambient air pollution. Adverse ef...
Epidemiological studies demonstrate an association between cardiovascular morbidity, arrhythmias, and exposure to air toxicants such as acrolein. We hypothesized that a single exposure to acrolein would increase arrhythmias and cause changes in the electrocardiogram (ECG) of hype...
Inhalation of particulate matter (PM) associated with air pollution causes adverse effects on cardiac function including heightened associations with ischemic heart disease, dysrhythmias, heart failure, and cardiac arrest. Some of these effects have been attributable to transitio...
Congenital Deafness with Cardiac Arrhythmias: The Jervell and Lange-Nielsen Syndrome.
ERIC Educational Resources Information Center
Wahl, Richard A.; Macdonald, Dick, II
1980-01-01
The Jervell and Lange-Nielsen syndrome, affecting 0.3 percent of congenitally deaf persons, consists of severe cardiac arrhythmias and sensorineural hearing loss. The authors recommend that every congenitally deaf child with suspicious symptoms receive an electrocardiogram and that professionals who work with deaf children not only inform…
Numerous studies have shown a relationship between acute air pollution exposure and increased risk for cardiovascular morbidity and mortality. Due to the inherent complexity of air pollution, recent studies have focused on co-exposures to better understand potential interactions....
A microcontroller-based portable electrocardiograph recorder.
Segura-Juárez, José J; Cuesta-Frau, David; Samblas-Pena, Luis; Aboy, Mateo
2004-09-01
We describe a low cost portable Holter design that can be implemented with off-the-shelf components. The recorder is battery powered and includes a graphical display and keyboard. The recorder is capable of acquiring up to 48 hours of continuous electrocardiogram data at a sample rate of up to 250 Hz.
Deriving the 12-Lead Electrocardiogram From Four Standard Leads Based on the Frank Torso Model
2001-10-25
System The University of Aizu, Fukushima Prefecture, Japan Abstract – This paper proposes a lead method and a processing means for monitoring the 12...Performing Organization Name(s) and Address(es) The University of Aizu Graduate School of Information System Fukushima Prefecture, Japan Performing
20 CFR 718.104 - Report of physical examinations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 4 2012-04-01 2012-04-01 false Report of physical examinations. 718.104... of physical examinations. (a) A report of any physical examination conducted in connection with a... report of physical examination may be based on any other procedures such as electrocardiogram, blood-gas...
Portable medical status and treatment system
NASA Technical Reports Server (NTRS)
1981-01-01
A portable medical status and treatment system is discussed. The vital signs monitor includes electrocardiogram, respiration, temperature, blood pressure, alarm, and power subsystems, which are described. A DC defibrillator module, a radio module, and their packaging are also described. These subsystems were evaluated and the results and recommendations are presented.
Electrocardiography (ECG) is one of the standard technologies used to monitor and assess cardiac function, and provide insight into the mechanisms driving myocardial pathology. Increased understanding of the effects of cardiovascular disease on rat ECG may help make ECG assessmen...
Cardiac Electrophysiology: Normal and Ischemic Ionic Currents and the ECG
ERIC Educational Resources Information Center
Klabunde, Richard E.
2017-01-01
Basic cardiac electrophysiology is foundational to understanding normal cardiac function in terms of rate and rhythm and initiation of cardiac muscle contraction. The primary clinical tool for assessing cardiac electrical events is the electrocardiogram (ECG), which provides global and regional information on rate, rhythm, and electrical…
ECG Identification System Using Neural Network with Global and Local Features
ERIC Educational Resources Information Center
Tseng, Kuo-Kun; Lee, Dachao; Chen, Charles
2016-01-01
This paper proposes a human identification system via extracted electrocardiogram (ECG) signals. Two hierarchical classification structures based on global shape feature and local statistical feature is used to extract ECG signals. Global shape feature represents the outline information of ECG signals and local statistical feature extracts the…
Mild-to-moderate exercise is often used to stress the cardiovascular (CV) system of patients while monitoring them for electrocardiogram (ECG) abnormalities that may indicate underlying CV disease. We previously demonstrated that dobutamine, which increases heart rate (HR) and co...
III SBC Guidelines on the Analysis and Issuance of Electrocardiographic Reports - Executive Summary
Pastore, Carlos Alberto; Samesima, Nelson; Pereira-Filho, Horacio Gomes
2016-01-01
The third version of the guidelines covers recently described topics, such as ion channel diseases, acute ischemic changes, the electrocardiogram in athletes, and analysis of ventricular repolarization. It sought to revise the criteria for overloads, conduction disorders, and analysis of data for internet transmission. PMID:27982266
ECG Monitoring in Cardiac Rehabilitation: Is It Needed?
ERIC Educational Resources Information Center
Greenland, Philip; Pomilla, Paul V.
1989-01-01
Discusses the controversial use of continuous electrocardiogram (ECG) monitoring as a safety measure in cardiac rehabilitation exercise programs. Little evidence substantiates its value for all patients during exercise. In the absence of empirical evidence documenting the worth of this expensive procedure, it is recommended for use with high-risk…
Tic Reduction with Risperidone Versus Pimozide in a Randomized, Double-Blind, Crossover Trial
ERIC Educational Resources Information Center
Gilbert, Donald L.; Batterson, J. Robert; Sethuraman, Gopalan; Sallee, Floyd R.
2004-01-01
Objective: To compare the tic suppression, electrocardiogram (ECG) changes, weight gain, and side effect profiles of pimozide versus risperidone in children and adolescents with tic disorders. Method: This was a randomized, double-blind, crossover (evaluable patient analysis) study. Nineteen children aged 7 to 17 years with Tourette's or chronic…
31 CFR 346.8 - Payment or redemption during lifetime of owner.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., electrocardiogram, or other objective findings, so that despite medical treatment breathlessness, pain, or fatigue... any of the owner's bonds are submitted for payment to a Federal Reserve Bank or Branch or to the... individual annuity, an employees' trust, or annuity plan, as described in sections 408(a), 408(b), 401(a) and...
31 CFR 346.8 - Payment or redemption during lifetime of owner.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., electrocardiogram, or other objective findings, so that despite medical treatment breathlessness, pain, or fatigue... any of the owner's bonds are submitted for payment to a Federal Reserve Bank or Branch or to the... individual annuity, an employees' trust, or annuity plan, as described in sections 408(a), 408(b), 401(a) and...
31 CFR 346.8 - Payment or redemption during lifetime of owner.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., electrocardiogram, or other objective findings, so that despite medical treatment breathlessness, pain, or fatigue... any of the owner's bonds are submitted for payment to a Federal Reserve Bank or Branch or to the... individual annuity, an employees' trust, or annuity plan, as described in sections 408(a), 408(b), 401(a) and...
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
Mild-to-moderate exercise is often used to stress the cardiovascular (CV) system of patients while monitoring them for electrocardiogram (ECG) abnormalities that may indicate underlying CV disease. We previously used dobutamine, which increases heart rate (HR) and contractility, ...
ERIC Educational Resources Information Center
van den Berge, Kees; van Gog, Tamara; Mamede, Silvia; Schmidt, Henk G.; van Saase, Jan L. C. M.; Rikers, Remy M. J. P.
2013-01-01
Research has shown that for acquiring problem-solving skills, instruction consisting of studying worked examples is more effective and efficient for novice learners than instruction consisting of problem-solving. This study investigated whether worked examples would also be a useful instructional format for the acquisition of visual perceptual…
21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...
21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...
21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...
Sex differences in human cardiovascular stress responses: mathematical and physiological approaches
NASA Astrophysics Data System (ADS)
Anishchenko, Tatijana G.; Igosheva, N. B.; Saparin, P. I.
1993-06-01
A new quantitative electrocardiogram characteristic is introduced as a distribution entropy, normalized by the signal energy. A perspective of this parameter application as a diagnostic criterion is proved by series of test experiments. By way of comparison with traditional medico-biological characteristics the higher sensitivity and stability of this criterion is proved.
BackgroundStudies have shown a relationship between air pollution and increased risk of cardiovascular morbidity and mortality. Due to the complexity of ambient air pollution composition, recent studies have examined the effects of co-exposure, particularly particulate matter (PM...
The Use of Computer Networks in Data Gathering and Data Analysis.
ERIC Educational Resources Information Center
Yost, Michael; Bremner, Fred
This document describes the review, analysis, and decision-making process that Trinity University, Texas, went through to develop the three-part computer network that they use to gather and analyze EEG (electroencephalography) and EKG (electrocardiogram) data. The data are gathered in the laboratory on a PDP-1124, an analog minicomputer. Once…
Doxorubicin (DOX) is a widely used anthracycline anti-neoplastic drug used to treat tumors. However it has been implicated in irreversible cardiac toxicity via the generation of a proxidant semiquinone free radical, which often results in cardiomyopathy and changes in the ECG. Ac...
Clinical Application of Electrocardiography.
ERIC Educational Resources Information Center
Brammell, H. L.; Orr, William
The scalar electrocardiogram (ECG) is one of the most important and commonly used clinical tools in medicine. A detailed description of the recordings of cardiac electrical activity made by the ECG is presented, and the vast numbers of uses made with the data provided by this diagnostic tool are cited. Clinical applications of the ECG are listed.…
ERIC Educational Resources Information Center
Lee, Jung A.
2011-01-01
Web-based tailored approaches hold much promise as effective means for delivering health education and improving public health. This study examines the effects of interactive tailored health videos on attention to health messages using neurophysiological changes measured by Electroencephalogram (EEG) and Electrocardiogram (EKG). Sixty-eight…
[Diagnostic performance of surface electrocardiogram in early detection of chagasic cardiomyopathy].
Bochard-Villanueva, Bruno; Estornell-Erill, Jordi; Fabregat-Andrés, Óscar; García-González, Pilar; Morell-Cabedo, Salvador; Ridocci-Soriano, Francisco
2015-03-15
Contrast-enhanced cardiac magnetic resonance imaging (CMR) allows early detection of myocardial involvement by Trypanosoma cruzi infection. The aim of our study was to assess the diagnostic performance of the surface electrocardiogram (ECG) in the early detection of Chagas' cardiomyopathy (CCM) compared with CMR. We included 43 asymptomatic patients (30 women, 42 ± 9.8 years), diagnosed of Chagas disease. The sample was divided into 2 groups according to the presence (n=17) or absence (n=26) of electrocardiographic abnormalities. All patients underwent CMR and late gadolinium enhancement (LGE) was used as a marker of early myocardial involvement. Six (14%) patients had a LGE significantly higher in the group who had electrocardiographic abnormalities (29 vs. 4%, P<.05). With CMR as the method of reference, the ECG had a sensitivity of 83% and a negative predictive value of 96% to detect CCM. ECG is a useful, inexpensive and globally available tool for the screening of CCM in asymptomatic patients but with proven myocardial involvement in CMR. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.
[An Improved Cubic Spline Interpolation Method for Removing Electrocardiogram Baseline Drift].
Wang, Xiangkui; Tang, Wenpu; Zhang, Lai; Wu, Minghu
2016-04-01
The selection of fiducial points has an important effect on electrocardiogram(ECG)denoise with cubic spline interpolation.An improved cubic spline interpolation algorithm for suppressing ECG baseline drift is presented in this paper.Firstly the first order derivative of original ECG signal is calculated,and the maximum and minimum points of each beat are obtained,which are treated as the position of fiducial points.And then the original ECG is fed into a high pass filter with 1.5Hz cutoff frequency.The difference between the original and the filtered ECG at the fiducial points is taken as the amplitude of the fiducial points.Then cubic spline interpolation curve fitting is used to the fiducial points,and the fitting curve is the baseline drift curve.For the two simulated case test,the correlation coefficients between the fitting curve by the presented algorithm and the simulated curve were increased by 0.242and0.13 compared with that from traditional cubic spline interpolation algorithm.And for the case of clinical baseline drift data,the average correlation coefficient from the presented algorithm achieved 0.972.
Gulizia, Michele Massimo; Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Franco Gensini, Gian
2017-05-01
The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, elaboration, and presentation of the signal. Several sources of artefacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depend upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high-quality ECG signal are, therefore, of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to give scientific reference for the choice of systems able to offer high quality ECG signal acquisition, processing, and presentation suitable for clinical use.
Design of portable electrocardiogram device using DSO138
NASA Astrophysics Data System (ADS)
Abuzairi, Tomy; Matondang, Josef Stevanus; Purnamaningsih, Retno Wigajatri; Basari, Ratnasari, Anita
2018-02-01
Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.
Chai, Norin; Pouchelon, Jean Louis; Bouvard, Jonathan; Sillero, Leonor Camacho; Huynh, Minh; Segalini, Vincent; Point, Lisa; Croce, Veronica; Rigaux, Goulven; Highwood, Jack; Chetboul, Valérie
2016-03-01
Electrocardiography represents a relevant diagnostic tool for detecting cardiac disease in animals. Elephants can present various congenital and acquired cardiovascular diseases. However, few electrophysiologic studies have been reported in captive elephants, mainly due to challenging technical difficulties in obtaining good-quality electrocardiogram (ECG) tracings, and no data are currently available for free-ranging Asian elephants (Elephas maximus). The purpose of this pilot prospective study was to evaluate the feasibility of using a simple method for recording ECG tracings in wild, apparently healthy, unsedated Asian elephants (n = 7) in the standing position. Successful six-lead recordings (I, II, III, aVR, aVL, and aVF) were obtained, with the aVL lead providing the best-quality tracings in most animals. Variables measured in the aVL lead included heart rate, amplitudes and duration of the P waves, QRS complexes, T and U waves, and duration of the PR, QT, and QU intervals. A negative deflection following positive P waves, representative of an atrial repolarization wave (Ta wave), was observed for five out of the seven elephants.
Edla, Shwetha; Kovvali, Narayan; Papandreou-Suppappola, Antonia
2012-01-01
Constructing statistical models of electrocardiogram (ECG) signals, whose parameters can be used for automated disease classification, is of great importance in precluding manual annotation and providing prompt diagnosis of cardiac diseases. ECG signals consist of several segments with different morphologies (namely the P wave, QRS complex and the T wave) in a single heart beat, which can vary across individuals and diseases. Also, existing statistical ECG models exhibit a reliance upon obtaining a priori information from the ECG data by using preprocessing algorithms to initialize the filter parameters, or to define the user-specified model parameters. In this paper, we propose an ECG modeling technique using the sequential Markov chain Monte Carlo (SMCMC) filter that can perform simultaneous model selection, by adaptively choosing from different representations depending upon the nature of the data. Our results demonstrate the ability of the algorithm to track various types of ECG morphologies, including intermittently occurring ECG beats. In addition, we use the estimated model parameters as the feature set to classify between ECG signals with normal sinus rhythm and four different types of arrhythmia.
Intermittent bradyarrhythmia in a Hispaniolan Amazon parrot (Amazona ventralis).
Rembert, Melanie S; Smith, Julie A; Strickland, Keith N; Tully, Thomas N
2008-03-01
A clinically normal 2-year-old Hispaniolan Amazon parrot (Amazona ventralis) was found to have periodic second-degree atrioventricular (AV) block with variable nodal conductions while anesthetized with isoflurane during a thermal-support research project. Arrhythmias were observed on 5 successive weekly electrocardiograms. A complete cardiac evaluation, including a diagnostic electrocardiogram, revealed intermittent bradyarrhythmias ranging from a 2:1 to a 7:1 second-degree AV block, with concurrent hypotensive episodes during the nodal blocks. Results of a complete blood cell count, plasma biochemical profile, blood gas analysis, and atropine-response test, as well as radiography and auscultation, revealed no obvious cause for the arrhythmias. Echocardiography demonstrated cardiac wall thickness, chamber size, and systolic function similar to other psittacine birds. On return to the colony, the parrot continued to be outwardly asymptomatic despite the dramatic conduction disturbances. Although cardiac arrhythmias, including second-degree AV block, have been widely reported in birds, the wide variation of nodal conductions, the intermittent nature, and an arrhythmia with a 7:1 second-degree AV block that spontaneously reverts to normal as seen in this case have not been well documented in parrots.
Compressed sensing of ECG signal for wireless system with new fast iterative method.
Tawfic, Israa; Kayhan, Sema
2015-12-01
Recent experiments in wireless body area network (WBAN) show that compressive sensing (CS) is a promising tool to compress the Electrocardiogram signal ECG signal. The performance of CS is based on algorithms use to reconstruct exactly or approximately the original signal. In this paper, we present two methods work with absence and presence of noise, these methods are Least Support Orthogonal Matching Pursuit (LS-OMP) and Least Support Denoising-Orthogonal Matching Pursuit (LSD-OMP). The algorithms achieve correct support recovery without requiring sparsity knowledge. We derive an improved restricted isometry property (RIP) based conditions over the best known results. The basic procedures are done by observational and analytical of a different Electrocardiogram signal downloaded them from PhysioBankATM. Experimental results show that significant performance in term of reconstruction quality and compression rate can be obtained by these two new proposed algorithms, and help the specialist gathering the necessary information from the patient in less time if we use Magnetic Resonance Imaging (MRI) application, or reconstructed the patient data after sending it through the network. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Franco Gensini, Gian
2017-01-01
Abstract The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, elaboration, and presentation of the signal. Several sources of artefacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depend upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high-quality ECG signal are, therefore, of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to give scientific reference for the choice of systems able to offer high quality ECG signal acquisition, processing, and presentation suitable for clinical use. PMID:28751842
Algorithm for the classification of multi-modulating signals on the electrocardiogram.
Mita, Mitsuo
2007-03-01
This article discusses the algorithm to measure electrocardiogram (ECG) and respiration simultaneously and to have the diagnostic potentiality for sleep apnoea from ECG recordings. The algorithm is composed by the combination with the three particular scale transform of a(j)(t), u(j)(t), o(j)(a(j)) and the statistical Fourier transform (SFT). Time and magnitude scale transforms of a(j)(t), u(j)(t) change the source into the periodic signal and tau(j) = o(j)(a(j)) confines its harmonics into a few instantaneous components at tau(j) being a common instant on two scales between t and tau(j). As a result, the multi-modulating source is decomposed by the SFT and is reconstructed into ECG, respiration and the other signals by inverse transform. The algorithm is expected to get the partial ventilation and the heart rate variability from scale transforms among a(j)(t), a(j+1)(t) and u(j+1)(t) joining with each modulation. The algorithm has a high potentiality of the clinical checkup for the diagnosis of sleep apnoea from ECG recordings.
The effect of respiratory oscillations in heart rate on detrended fluctuation analysis
NASA Astrophysics Data System (ADS)
Govindan, Rathinaswamy B.; Kota, Srinivas; Al-Shargabi, Tareq; Swisher, Christopher B.; du Plessis, Adre
2017-10-01
Characterization of heart rate using detrended fluctuation analysis (DFA) is impeded by respiratory oscillations. In particular, the short-term exponent measured from 15 to 30 beats is compromised in the DFA. We reconstruct respiratory signal from electrocardiograms and attenuate the respiratory oscillation in the heart rate using a frequency-dependent subtraction approach. We validate this method by applying it to an electrocardiogram signal simulated using a coupled differential equation with the respiratory oscillation modelled using a sine function. The exponent estimated using the proposed approach agreed with the exponent incorporated in the model within a narrow range. In contrast, the exponent obtained from the raw data deviated from the expected value. Furthermore, the exponents obtained for the raw heart rate are smaller than the exponents obtained for the respiration oscillation attenuated heart rate. We apply this approach to heart rate measured from 12 preterm infants that were being treated for prematurity related complications. As observed in the simulated data, we show that compared to the raw heart rate, the respiratory oscillation attenuated heart rate shows higher short-term exponent (p < 0.001).
Predictable and reliable ECG monitoring over IEEE 802.11 WLANs within a hospital.
Park, Juyoung; Kang, Kyungtae
2014-09-01
Telecardiology provides mobility for patients who require constant electrocardiogram (ECG) monitoring. However, its safety is dependent on the predictability and robustness of data delivery, which must overcome errors in the wireless channel through which the ECG data are transmitted. We report here a framework that can be used to gauge the applicability of IEEE 802.11 wireless local area network (WLAN) technology to ECG monitoring systems in terms of delay constraints and transmission reliability. For this purpose, a medical-grade WLAN architecture achieved predictable delay through the combination of a medium access control mechanism based on the point coordination function provided by IEEE 802.11 and an error control scheme based on Reed-Solomon coding and block interleaving. The size of the jitter buffer needed was determined by this architecture to avoid service dropout caused by buffer underrun, through analysis of variations in transmission delay. Finally, we assessed this architecture in terms of service latency and reliability by modeling the transmission of uncompressed two-lead electrocardiogram data from the MIT-BIH Arrhythmia Database and highlight the applicability of this wireless technology to telecardiology.
Proton Beam Therapy Interference With Implanted Cardiac Pacemakers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oshiro, Yoshiko; Sugahara, Shinji; Noma, Mio
2008-11-01
Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined beforemore » and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.« less
Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection.
Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae
2017-06-12
Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan-Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities.
Teaching crucial skills: An electrocardiogram teaching module for medical students.
Chudgar, Saumil M; Engle, Deborah L; Grochowski, Colleen O'Connor; Gagliardi, Jane P
2016-01-01
Medical student performance in electrocardiogram (ECG) interpretation at our institution could be improved. Varied resources exist to teach students this essential skill. We created an ECG teaching module (ECGTM) of 75 cases representing 15 diagnoses to improve medical students' performance and confidence in ECG interpretation. Students underwent pre- and post-clerkship testing to assess ECG interpretation skills and confidence and also end-of-clinical-year testing in ECG and laboratory interpretation. Performance was compared for the years before and during ECGTM availability. Eighty-four percent of students (total n=101) reported using the ECGTM; 98% of those who used it reported it was useful. Students' performance and confidence were higher on the post-test. Students with access to the ECGTM (n=101) performed significantly better than students from the previous year (n=90) on the end-of-year ECG test. The continuous availability of an ECGTM was associated with improved confidence and ability in ECG interpretation. The ECGTM may be another available tool to help students as they learn to read ECGs. Copyright © 2016 Elsevier Inc. All rights reserved.
Electrocardiogram interpretation and arrhythmia management: a primary and secondary care survey.
Begg, Gordon; Willan, Kathryn; Tyndall, Keith; Pepper, Chris; Tayebjee, Muzahir
2016-05-01
There is increasing desire among service commissioners to treat arrhythmia in primary care. Accurate interpretation of the electrocardiogram (ECG) is fundamental to this. ECG interpretation has previously been shown to vary widely but there is little recent data. To examine the interpretation of ECGs in primary and secondary care. A cross-sectional survey of participants' interpretation of six ECGs and hypothetical management of patients based on those ECGs, at primary care educational events, and a cardiology department in Leeds. A total of 262 primary care clinicians and 20 cardiology clinicians were surveyed via questionnaire. Answers were compared with expert electrophysiologist opinion. In primary care, abnormal ECGs were interpreted as normal by 23% of responders. ST elevation and prolonged QT were incorrectly interpreted as normal by 1% and 22%, respectively. In cardiology, abnormal ECGs were interpreted as normal by 3%. ECG provision and interpretation remains inconsistent in both primary and secondary care. Primary care practitioners are less experienced and less confident with ECG interpretation than cardiologists, and require support in this area. © British Journal of General Practice 2016.
Noninvasive recording of electrocardiogram in conscious rat: A new device.
Kumar, Pradeep; Srivastava, Pooja; Gupta, Ankit; Bajpai, Manish
2017-01-01
Electrocardiogram (ECG) is an important tool for the study of cardiac electrophysiology both in human beings and experimental animals. Existing methods of ECG recording in small animals like rat have several limitations and ECG recordings of the anesthetized rat lack validity for heart rate (HR) variability analysis. The aim of the present study was to validate the ECG data from new device with ECG of anesthetized rat. The ECG was recorded on student's physiograph (BioDevice, Ambala) and suitable coupler and electrodes in six animals first by the newly developed device in conscious state and second in anesthetized state (stabilized technique). The data obtained were analyzed using unpaired t -test showed no significant difference ( P < 0.05) in QTc, QRS, and HR recorded by new device and established device in rats. No previous study describes a similar ECG recording in conscious state of rats. Thus, the present method may be a most physiological and inexpensive alternative to other methods. In this study, the animals were not restrained; they were just secured and represent a potential strength of the study.
Man, Sumche; Maan, Arie C; Schalij, Martin J; Swenne, Cees A
2015-01-01
In the course of time, electrocardiography has assumed several modalities with varying electrode numbers, electrode positions and lead systems. 12-lead electrocardiography and 3-lead vectorcardiography have become particularly popular. These modalities developed in parallel through the mid-twentieth century. In the same time interval, the physical concepts underlying electrocardiography were defined and worked out. In particular, the vector concept (heart vector, lead vector, volume conductor) appeared to be essential to understanding the manifestations of electrical heart activity, both in the 12-lead electrocardiogram (ECG) and in the 3-lead vectorcardiogram (VCG). Not universally appreciated in the clinic, the vectorcardiogram, and with it the vector concept, went out of use. A revival of vectorcardiography started in the 90's, when VCGs were mathematically synthesized from standard 12-lead ECGs. This facilitated combined electrocardiography and vectorcardiography without the need for a special recording system. This paper gives an overview of these historical developments, elaborates on the vector concept and seeks to define where VCG analysis/interpretation can add diagnostic/prognostic value to conventional 12-lead ECG analysis. Copyright © 2015 Elsevier Inc. All rights reserved.
Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection †
Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae
2017-01-01
Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan–Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities. PMID:28604628
Adams, Jenny; Pullum, Gwen; Stafford, Pamala; Hanners, Nava; Hartman, Julie; Strauss, Danielle; Hubbard, Matt; Lawrence, Anne; Anderson, Valerie; McCullough, Tiffany
2008-01-01
Physician advice and restrictions to patients following a cardiac event can, in some instances, lead patients to be fearful regarding their activities even to the point of inactivity. The purpose of this study was to test whether lawn mowing, one of the activities most strongly discouraged after coronary artery bypass surgery, could be safely performed in a supervised setting. Subjects participated in a 6-session simulated lawn-mowing protocol, calibrated to match the push and pull forces of using an outdoor nonpropelled lawn mower. Plain chest radiographs were taken before and after the protocol period. During each session, subjects' sternums were carefully palpated and electrocardiograms, heart rates, and blood pressures were monitored. None of the 13 subjects experienced adverse arrhythmia events or detrimental heart rate, blood pressure, or sternal palpation findings that led to study discontinuation. The radiographs taken after protocol completion showed stable sternal wires with no evidence of sternal dehiscence. Simulated lawn mowing did not negatively affect the sternal incision, electrocardiogram findings, blood pressure, or heart rate in this small sample.
Electrocardiogram signal denoising based on empirical mode decomposition technique: an overview
NASA Astrophysics Data System (ADS)
Han, G.; Lin, B.; Xu, Z.
2017-03-01
Electrocardiogram (ECG) signal is nonlinear and non-stationary weak signal which reflects whether the heart is functioning normally or abnormally. ECG signal is susceptible to various kinds of noises such as high/low frequency noises, powerline interference and baseline wander. Hence, the removal of noises from ECG signal becomes a vital link in the ECG signal processing and plays a significant role in the detection and diagnosis of heart diseases. The review will describe the recent developments of ECG signal denoising based on Empirical Mode Decomposition (EMD) technique including high frequency noise removal, powerline interference separation, baseline wander correction, the combining of EMD and Other Methods, EEMD technique. EMD technique is a quite potential and prospective but not perfect method in the application of processing nonlinear and non-stationary signal like ECG signal. The EMD combined with other algorithms is a good solution to improve the performance of noise cancellation. The pros and cons of EMD technique in ECG signal denoising are discussed in detail. Finally, the future work and challenges in ECG signal denoising based on EMD technique are clarified.
Thomas, Robert Joseph; Mietus, Joseph E.; Peng, Chung-Kang; Gilmartin, Geoffrey; Daly, Robert W.; Goldberger, Ary L.; Gottlieb, Daniel J.
2007-01-01
Study Objectives: Complex sleep apnea is defined as sleep disordered breathing secondary to simultaneous upper airway obstruction and respiratory control dysfunction. The objective of this study was to assess the utility of an electrocardiogram (ECG)-based cardiopulmonary coupling technique to distinguish obstructive from central or complex sleep apnea. Design: Analysis of archived polysomnographic datasets. Setting: A laboratory for computational signal analysis. Interventions: None. Measurements and Results: The PhysioNet Sleep Apnea Database, consisting of 70 polysomnograms including single-lead ECG signals of approximately 8 hours duration, was used to train an ECG-based measure of autonomic and respiratory interactions (cardiopulmonary coupling) to detect periods of apnea and hypopnea, based on the presence of elevated low-frequency coupling (e-LFC). In the PhysioNet BIDMC Congestive Heart Failure Database (ECGs of 15 subjects), a pattern of “narrow spectral band” e-LFC was especially common. The algorithm was then applied to the Sleep Heart Health Study–I dataset, to select the 15 records with the highest amounts of broad and narrow spectral band e-LFC. The latter spectral characteristic seemed to detect not only periods of central apnea, but also obstructive hypopneas with a periodic breathing pattern. Applying the algorithm to 77 sleep laboratory split-night studies showed that the presence of narrow band e-LFC predicted an increased sensitivity to induction of central apneas by positive airway pressure. Conclusions: ECG-based spectral analysis allows automated, operator-independent characterization of probable interactions between respiratory dyscontrol and upper airway anatomical obstruction. The clinical utility of spectrographic phenotyping, especially in predicting failure of positive airway pressure therapy, remains to be more thoroughly tested. Citation: Thomas RJ; Mietus JE; Peng CK; Gilmartin G; Daly RW; Goldberger AL; Gottlieb DJ. Differentiating obstructive from central and complex sleep apnea using an automated electrocardiogram-based method. SLEEP 2007;30(12):1756-1769. PMID:18246985
Inorganic Nitrate in Angina Study: A Randomized Double-Blind Placebo-Controlled Trial.
Schwarz, Konstantin; Singh, Satnam; Parasuraman, Satish K; Rudd, Amelia; Shepstone, Lee; Feelisch, Martin; Minnion, Magdalena; Ahmad, Shakil; Madhani, Melanie; Horowitz, John; Dawson, Dana K; Frenneaux, Michael P
2017-09-08
In this double-blind randomized placebo-controlled crossover trial, we investigated whether oral sodium nitrate, when added to existing background medication, reduces exertional ischemia in patients with angina. Seventy patients with stable angina, positive electrocardiogram treadmill test, and either angiographic or functional test evidence of significant ischemic heart disease were randomized to receive oral treatment with either placebo or sodium nitrate (600 mg; 7 mmol) for 7 to 10 days, followed by a 2-week washout period before crossing over to the other treatment (n=34 placebo-nitrate, n=36 nitrate-placebo). At baseline and at the end of each treatment, patients underwent modified Bruce electrocardiogram treadmill test, modified Seattle Questionnaire, and subgroups were investigated with dobutamine stress, echocardiogram, and blood tests. The primary outcome was time to 1 mm ST depression on electrocardiogram treadmill test. Compared with placebo, inorganic nitrate treatment tended to increase the primary outcome exercise time to 1 mm ST segment depression (645.6 [603.1, 688.0] seconds versus 661.2 [6183, 704.0] seconds, P =0.10) and significantly increased total exercise time (744.4 [702.4, 786.4] seconds versus 760.9 [719.5, 802.2] seconds, P =0.04; mean [95% confidence interval]). Nitrate treatment robustly increased plasma nitrate (18.3 [15.2, 21.5] versus 297.6 [218.4, 376.8] μmol/L, P <0.0001) and almost doubled circulating nitrite concentrations (346 [285, 405] versus 552 [398, 706] nmol/L, P =0.003; placebo versus nitrate treatment). Other secondary outcomes were not significantly altered by the intervention. Patients on antacid medication appeared to benefit less from nitrate supplementation. Sodium nitrate treatment may confer a modest exercise capacity benefit in patients with chronic angina who are taking other background medication. URL: https://www.clinicaltrials.gov/. Unique identifier: NCT02078921. EudraCT number: 2012-000196-17. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Gundersen, Kenneth; Kvaløy, Jan Terje; Kramer-Johansen, Jo; Steen, Petter Andreas; Eftestøl, Trygve
2009-02-06
One of the factors that limits survival from out-of-hospital cardiac arrest is the interruption of chest compressions. During ventricular fibrillation and tachycardia the electrocardiogram reflects the probability of return of spontaneous circulation associated with defibrillation. We have used this in the current study to quantify in detail the effects of interrupting chest compressions. From an electrocardiogram database we identified all intervals without chest compressions that followed an interval with compressions, and where the patients had ventricular fibrillation or tachycardia. By calculating the mean-slope (a predictor of the return of spontaneous circulation) of the electrocardiogram for each 2-second window, and using a linear mixed-effects statistical model, we quantified the decline of mean-slope with time. Further, a mapping from mean-slope to probability of return of spontaneous circulation was obtained from a second dataset and using this we were able to estimate the expected development of the probability of return of spontaneous circulation for cases at different levels. From 911 intervals without chest compressions, 5138 analysis windows were identified. The results show that cases with the probability of return of spontaneous circulation values 0.35, 0.1 and 0.05, 3 seconds into an interval in the mean will have probability of return of spontaneous circulation values 0.26 (0.24-0.29), 0.077 (0.070-0.085) and 0.040(0.036-0.045), respectively, 27 seconds into the interval (95% confidence intervals in parenthesis). During pre-shock pauses in chest compressions mean probability of return of spontaneous circulation decreases in a steady manner for cases at all initial levels. Regardless of initial level there is a relative decrease in the probability of return of spontaneous circulation of about 23% from 3 to 27 seconds into such a pause.
Barrios, V; Calderón, A; Coca, A; González-Juanatey, J R; Sarríá, A; Rodríguez-Padial, L
2011-09-01
Despite its low sensitivity, the electrocardiogram (ECG) is the tool used the most in the daily practice for detection of left ventricular hypertrophy (LVH). This study has aimed to assess the impact of the computerized interpretation of the ECG on the diagnosis of LVH in the practical clinical setting. ELECTROPRES is a project based on a free access computer platform that permits an online interpretation of the electrocardiogram. It includes 19 different left LVH criteria previously validated by echocardiography in a substudy. We analyzed the data from the first 669 patients with essential arterial hypertension (ATH) included in the ELECTROPRES platform from 21 primary care centers in 9 of the 17 Spanish autonomous communities. Up to April 2010, a cohort of 669 hypertensive patients (51.7% women), with a mean age of 66.3±11.89 years, was analyzed. The mean evolution of the disease was 8 years, and the patients had been receiving an average of 2.4 antihypertensive agents. Systolic blood pressure was 139±17 mmHg and diastolic blood pressure 76±11. The ECG-known frequency of LVH was 3%. The prevalence of LVH increased up to 33.3% (P<0.001) with the ELECTROPRES platform. When all the criteria were independently examined, the Lewis index (R-I+S-III) and the Cornell product [(R-aVL+S-V3 (+6 for women)] were those in which the most cases of left ventricular hypertrophy were detected (24.8% and 13.3%, respectively). The Lewis index and the Cornell product were the criteria that detected more cases of left ventricular hypertrophy, regardless of the AHT stage and of the presence of cardiovascular complications. The ECG computerized reading (ELECTROPRES platform) significantly increases detection of left ventricular hypertrophy in a population of essential hypertense subjects compared to conventional detection with the ECG by the physician in the usual clinical practice setting. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Necessity of hospitalization and stress testing in low risk chest pain patients.
Beri, Neil; Marston, Nicholas A; Daniels, Lori B; Nowak, Richard M; Schreiber, Donald; Mueller, Christian; Jaffe, Allan; Diercks, Deborah B; Wettersten, Nicholas; DeFilippi, Christopher; Peacock, W Frank; Limkakeng, Alexander T; Anand, Inder; McCord, James; Hollander, Judd E; Wu, Alan H B; Apple, Fred S; Nagurney, John T; Berardi, Cecilia; Cannon, Chad M; Clopton, Paul; Neath, Sean-Xavier; Christenson, Robert H; Hogan, Christopher; Vilke, Gary; Maisel, Alan
2017-02-01
Copeptin is a marker of endogenous stress including early myocardial infarction(MI) and has value in early rule out of MI when used with cardiac troponin I(cTnI). The goal of this study was to demonstrate that patients with a normal electrocardiogram and cTnI<0.040μg/l and copeptin<14pmol/l at presentation and after 2 h may be candidates for early discharge with outpatient follow-up potentially including stress testing. This study uses data from the CHOPIN trial which enrolled 2071 patients with acute chest pain. Of those, 475 patients with normal electrocardiogram and normal cTnI(<0.040μg/l) and copeptin<14pmol/l at presentation and after 2 h were considered "low risk" and selected for further analysis. None of the 475 "low risk" patients were diagnosed with MI during the 180day follow-up period (including presentation). The negative predictive value of this strategy was 100% (95% confidence interval(CI):99.2%-100.0%). Furthermore no one died during follow up. 287 (60.4%) patients in the low risk group were hospitalized. In the "low risk" group, the only difference in outcomes (MI, death, revascularization, cardiac rehospitalization) was those hospitalized underwent revascularization more often (6.3%[95%CI:3.8%-9.7%] versus 0.5%[95%CI:0.0%-2.9%], p=.002). The hospitalized patients were tested significantly more via stress testing or angiogram (68.6%[95%CI:62.9%-74.0%] vs 22.9%[95%CI:17.1%-29.6%], p<.001). Those tested had less cardiac rehospitalizations during follow-up (1.7% vs 5.1%, p=.040). In conclusion, patients with a normal electrocardiogram, troponin and copeptin at presentation and after 2 h are at low risk for MI and death over 180days. These low risk patients may be candidates for early outpatient testing and cardiology follow-up thereby reducing hospitalization. Copyright © 2016 Elsevier Inc. All rights reserved.
Proposed Stages of Myocardial Phenotype Development in Fabry Disease.
Nordin, Sabrina; Kozor, Rebecca; Medina-Menacho, Katia; Abdel-Gadir, Amna; Baig, Shanat; Sado, Daniel M; Lobascio, Ilaria; Murphy, Elaine; Lachmann, Robin H; Mehta, Atul; Edwards, Nicola C; Ramaswami, Uma; Steeds, Richard P; Hughes, Derralynn; Moon, James C
2018-05-11
The authors sought to explore the Fabry myocardium in relation to storage, age, sex, structure, function, electrocardiogram changes, blood biomarkers, and inflammation/fibrosis. Fabry disease (FD) is a rare, x-linked lysosomal storage disorder. Mortality is mainly cardiovascular with men exhibiting cardiac symptoms earlier than women. By cardiovascular magnetic resonance, native T1 is low in FD because of sphingolipid accumulation. A prospective, observational study of 182 FD (167 adults, 15 children; mean age 42 ± 17 years, 37% male) who underwent cardiovascular magnetic resonance including native T1, late gadolinium enhancement (LGE), and extracellular volume fraction, 12-lead electrocardiogram, and blood biomarkers (troponin and N-terminal pro-brain natriuretic peptide). In children, T1 was never below the normal range, but was lower with age (9 ms/year, r = -0.78 children; r = -0.41 whole cohort; both p < 0.001). Over the whole cohort, the T1 reduction with age was greater and more marked in men (men: -1.9 ms/year, r = -0.51, p < 0.001; women: -1.4 ms/year, r = -0.47 women, p < 0.001). Left ventricular hypertrophy (LVH), LGE, and electrocardiogram abnormalities occur earlier in men. Once LVH occurs, T1 demonstrates major sex dimorphism: with increasing LVH in women, T1 and LVH become uncorrelated (r = -0.239, p = 0.196) but in men, the correlation reverses and T1 increases (toward normal) with LVH (r = 0.631, p < 0.001), a U-shaped relationship of T1 to indexed left ventricular mass in men. These data suggest that myocyte storage starts in childhood and accumulates faster in men before triggering 2 processes: a sex-independent scar/inflammation regional response (LGE) and, in men, apparent myocyte hypertrophy diluting the T1 lowering of sphingolipid. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Porter, Christin L.; Jones, Blake L.
2011-01-01
Using electrocardiogram data with 78 six-month-old infants, this study examined the presence or absence of brief orienting bradycardia during the onset of maternal arm-restraint and subsequent differences between infants on behavioral organization during restraint. Results showed that 45 of the infants exhibited brief episodes of bradycardia at…
Physiological Response to Social Evaluative Threat in Adolescents with Autism Spectrum Disorder
ERIC Educational Resources Information Center
Edmiston, E. Kale; Jones, Robin M.; Corbett, Blythe A.
2016-01-01
The Trier Social Stress Test (TSST) was employed to study response to social evaluative threat in male adolescents with Autism Spectrum Disorder (ASD, n = 21) and typical development (n = 13). Participants wore a mobile electrocardiogram to collect heart rate data. There were significant group effects on respiratory sinus arrhythmia (RSA), a…
Recurrent Ventricular Tachycardia and Peripheral Gangrene in a Young Child.
Vaiphei, Kim; Vaidya, Pankaj C; Vignesh, Pandiarajan; Barwad, Parag; Gupta, Anju
2016-09-08
A 10-year-old girl presented with sudden onset recurrent ventricular tachycardia and symmetrical distal peripheral gangrene. She also had pulmonary thromboembolism and cerebral sinus venous thrombosis. Investigations revealed anemia, hemolysis, hypocomplementemia, and elevated IgM anti-beta2 glycoprotein antibody levels. Electrocardiogram and echocardiogram suggested features of a rare cardiac anomaly, which was confirmed at autopsy.
Dry Electrodes Facilitate Remote Health Monitoring
NASA Technical Reports Server (NTRS)
2013-01-01
Johnson Space Center collaborated with Blacksburg, Virginia-based NanoSonic Inc. through the SBIR program to devise a sensor to replace the traditional electrodes used for an electrocardiogram in space. In 2011, NanoSonic started marketing the dry electrodes as well as an EKGear Sensor Shirt, which is being considered for use in hospital garments, athletic apparel, and dive suits.
WaveformECG: A Platform for Visualizing, Annotating, and Analyzing ECG Data
Winslow, Raimond L.; Granite, Stephen; Jurado, Christian
2017-01-01
The electrocardiogram (ECG) is the most commonly collected data in cardiovascular research because of the ease with which it can be measured and because changes in ECG waveforms reflect underlying aspects of heart disease. Accessed through a browser, WaveformECG is an open source platform supporting interactive analysis, visualization, and annotation of ECGs. PMID:28642673
MacAulay, Kevin
2002-01-01
An Ibizan hound cross was referred with a 1-year history of syncope and exercise intolerance. An electrocardiogram showed bradycardia and no P waves; atrial standstill was diagnosed. A permanent artificial endocardial pacemaker was implanted. The lead dislodged and was reimplanted into the right ventricular apex. Capture was once again achieved. PMID:12395764
Location of Disassociated P Wave in an Electrocardiogram
1978-12-01
34’A Computerized, Interactive Coronary Care Un-[t--onitoring System," IEEE Transactions on Biomedical Engineering, BME-24: 63-67--anuary 1977). 42...i02 !GO TO iig •:•102 IIP=PP (!K) -(513-ISTEP) ISTEP=i KNPT=LK+5 J=LK+i Fig. 29. Parameters to find the remaining P waves are set. equations modify
Accurate Interpretation of the 12-Lead ECG Electrode Placement: A Systematic Review
ERIC Educational Resources Information Center
Khunti, Kirti
2014-01-01
Background: Coronary heart disease (CHD) patients require monitoring through ECGs; the 12-lead electrocardiogram (ECG) is considered to be the non-invasive gold standard. Examples of incorrect treatment because of inaccurate or poor ECG monitoring techniques have been reported in the literature. The findings that only 50% of nurses and less than…
Wearable oximetry for harsh environments
2017-02-23
Firefighters, first responders, warfighters, and explorers must often operate in environmental extremes of temperature (hot or cold), humidity...PSMs) for thermal- work strain are maturing. These monitors typically measure heart rate (HR) from an electrocardiogram (ECG), skin temperature , and...add three primary benefits to PSMs: 1) monitoring altitude sickness and acclimatization via SpO2 (peripheral oxygen saturation) [2], 2) detecting
Aviation Medicine Research: A Historical Review.
1992-11-18
Laboratory Determinations b/ / / Pulmonary and Metabolic Spirometry / / / Basal Metabolic Rate / Other / / Anthropometry Somatotype...ELECTROCARDIOGRAMS x routine fasting x x treadmill stress (Bruce protocol) X x *VECTORCARDIOGRAM 1974-1977 x BALLISTOCARDIOGRAM X PULMONARY FUNCTION STUDIES X x...few occasions when we went in to pick up MEDCAP, there was a tremendous incidence of tuberculosis . We casualties that were the result of a firefight
Familial Brugada syndrome uncovered by hyperkalaemic diabetic ketoacidosis.
Postema, Pieter G; Vlaar, Alexander P J; DeVries, J Hans; Tan, Hanno L
2011-10-01
We describe a case of diabetic ketoacidosis with concomitant hyperkalaemia that uncovered a typical Brugada syndrome electrocardiogram (ECG). Further provocation testing in the patient and his son confirmed familial Brugada syndrome. Diabetic ketoacidosis with hyperkalaemia may uncover an inheritable arrhythmia syndrome that may put the patient and his/her next of kin at risk for a sudden death, irrespective of diabetes mellitus.
Sinoatrial block complicating legionnaire's disease.
Medarov, B; Tongia, S; Rossoff, L
2003-11-01
A 59 year old woman presented with acute onset of fever, chills, diaphoresis, vague chest discomfort, and was found to be hypotensive and tachypnoeic. An electrocardiogram demonstrated sinoatrial block with a junctional rhythm between 50 and 80 beats/min. All cultures were negative and imaging studies unrevealing. Her urine tested positive for Legionella pneumophila antigen serotype 1 and she improved with antibiotic therapy.
ERIC Educational Resources Information Center
Monk, Catherine; Sloan, Richard P.; Myers, Michael M.; Ellman, Lauren; Werner, Elizabeth; Jeon, Jiyeon; Tager, Felice; Fifer, William P.
2004-01-01
Objective: To determine whether there are differences in fetal heart rate (FHR) reactivity associated with women's psychiatric status. Method: In 57 women in their 36th to 38th week of pregnancy (mean age 27 [+ or -] 6 years), electrocardiogram, blood pressure (BP), respiration (RSP), and FHR were measured during baseline and a psychological…
Low-Noise Implantable Electrode
NASA Technical Reports Server (NTRS)
Lund, G. F.
1982-01-01
New implantable electrocardiogram electrode much less sensitive than previous designs to spurious biological potentials. Designed in novel "pocket" configuration, new electrode is intended as sensor for radiotelemetry of biological parameters in experiments on unrestrained subjects. Electrode is esentially squashed cylinder that admits body fluid into interior. Cylinder and electrical lead are made of stainless steel. Spot welding and crimping are used for assembly, rather than soldering.
ERIC Educational Resources Information Center
van Eijck, Michiel; Goedhart, Martin J.; Ellermeijer, Ton
2011-01-01
Polysemy in graph-related practices is the phenomenon that a single graph can sustain different meanings assigned to it. Considerable research has been done on polysemy in graph-related practices in school science in which graphs are rather used as scientific tools. However, graphs in science textbooks are also used rather pedagogically to…
ERIC Educational Resources Information Center
Jeffries, Pamela R.; Woolf, Shirley; Linde, Beverly
2003-01-01
Electrocardiogram technique was taught to 32 nursing students using a self-study module, lecture-demonstration, and hands-on learning laboratories and to 45 students using interactive multimedia CD-ROM with self-study module. Pre/postprogram data show satisfaction and score improvement was high for both, with no significant differences. (Contains…
2001-02-01
ECM Electronic Countermeasures EEG Electroencephalograph EKG Electrocardiogram EPA Extended Planning Annex EPF Equipment Performance Factor...related physiological measures Changes in the brain/neural system caused by workload. Rehmann, 1995, p. 12 M 8.2.16 Electroencephalograph ( EEG ...architecture TMD Operational Objectives: Destroy Theater Missiles ( TM ) and their infrastructure as far forward as possible (Attack Operations
Epstein-Barr virus myocarditis as the first symptom of infectious mononucleosis.
Zabala López, Sergio; Vicario, Juana M; Lerín, Francisco J; Fernández, Amalia; Pérez, Gloria; Fonseca, Cherpentier
2010-01-01
This case report describes a 20-year-old immunocompetent man with an episode of chest pain radiating into both arms, an increase in the level of myocardial enzymes, electrocardiogram abnormalities (widespread ST-segment elevation and q waves in leads V(4)-V(6)) and serological evidence for acute Epstein-Barr Virus infection preceding typical signs and symptoms of infectious mononucleosis.
Heo, Jin-Chul; Kim, Beomjoon; Kim, Yoon-Nyun; Kim, Dae-Kwang; Lee, Jong-Ha
2017-12-14
Prolonged monitoring by cardiac electrocardiogram (ECG) sensors is useful for patients with emergency heart conditions. However, implant monitoring systems are limited by lack of tissue biocompatibility. Here, we developed an implantable ECG sensor for real-time monitoring of ventricular fibrillation and evaluated its biocompatibility using an animal model. The implantable sensor comprised transplant sensors with two electrodes, a wireless power transmission system, and a monitoring system. The sensor was inserted into the subcutaneous tissue of the abdominal area and operated for 1 h/day for 5 days using a wireless power system. Importantly, the sensor was encapsulated by subcutaneous tissue and induced angiogenesis, inflammation, and phagocytosis. In addition, we observed that the levels of inflammation-related markers increased with wireless-powered transmission via the ECG sensor; in particular, levels of the Th-1 cytokine interleukin-12 were significantly increased. The results showed that induced tissue damage was associated with the use of wireless-powered sensors. We also investigated research strategies for the prevention of adverse effects caused by lack of tissue biocompatibility of a wireless-powered ECG monitoring system and provided information on the clinical applications of inflammatory reactions in implant treatment using the wireless-powered transmission system.
Exercise-induced ST-segment elevation during treadmill exercise testing.
Patanè, Salvatore; Marte, Filippo
2010-09-03
The exercise electrocardiogram is a commonly used non-invasive and inexpensive method for detection of electrocardiogram (ECG) changes secondary to myocardial ischemia. It has been reported that in patients with a first myocardial infarction and without residual ischemia, exercise-induced ST-segment elevation in Q leads is related to a more damaged coronary microcirculation and to less viable myocardium. Exercise-induced ST-segment elevation is a rare phenomenon in patients without prior myocardial infarction. When occurring purely during exercise, coronary lesions are frequent and often severe, and on the other hand ST-segment elevation of the recovery phase is frequently associated with normal arteries or less severe lesions. We present a case of exercise-induced ST-segment elevation in a 51-year-old Italian man. Coronary angiography revealed a significant left anterior descending coronary artery stenosis, a significant circumflex coronary artery stenosis, a significant first obtuse marginal coronary artery stenosis and a significant second obtuse marginal coronary artery stenosis. Percutaneous transluminal coronary angioplasty with implantation of stents was successfully performed. Also this case is illustrative of the rare phenomenon of exercise-induced ST-segment elevation. Copyright © 2008 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Smedal, Harald A.; Holden, George R.; Smith, Joseph R., Jr.
1960-01-01
A physiological instrumentation system capable of recording the electrocardiogram, pulse rate, respiration rate, and systolic and diastolic blood pressures during flight has been developed. This instrumentation system was designed for use during control studies at varied levels of acceleration in order to monitor the well-being of the pilot and at the same time to obtain data for study of the relationships between his various physiological functions and his performance capability. Flights, made in a T-33 aircraft, demonstrated the ability of the system to obtain the desired physiological data in flight. The data obtained in these flights, although limited in nature, indicate a slowing of the pulse rate under the subgravity conditions of brief duration. There appeared to be a proportional nearly in-phase relationship between pulse rate and acceleration. A decrease in diastolic blood pressure together with an increase in pulse pressure was noted during subgravity conditions and an elevation of the diastolic pressure together with a decrease in pulse pressure du-ring increased accelerations. No change worthy of note was seen in the records of the systolic blood pressure, the respiration rate, or the electrocardiogram over the range of acceleration studied (0 to 3 g).
Iron does not cause arrhythmias in the guinea pig model of transfusional iron overload.
Kaiser, Lana; Davis, John; Patterson, Jon; Boyd, Ryan F; Olivier, N Bari; Bohart, George; Schwartz, Kenneth A
2007-08-01
Cardiac events, including heart failure and arrhythmias, are the leading cause of death in patients with beta thalassemia. Although cardiac arrhythmias in humans are believed to result from iron overload, excluding confounding factors in the human population is difficult. The goal of the current study was to determine whether cardiac arrhythmias occurred in the guinea pig model of secondary iron overload. Electrocardiograms were recorded by using surgically implanted telemetry devices in guinea pigs loaded intraperitoneally with iron dextran (test animals) or dextran alone (controls). Loading occurred over approximately 6 wk. Electrocardiograms were recorded for 1 wk prior to loading, throughout loading, and for approximately 4 wk after loading was complete. Cardiac and liver iron concentrations were significantly increased in the iron-loaded animals compared with controls and were in the range of those reported for humans with thalassemia. Arrhythmias were rare in both iron-loaded and control guinea pigs. No life-threatening arrhythmias were detected in either group. These data suggest that iron alone may be insufficient to cause cardiac arrhythmias in the iron-loaded guinea pig model and that arrhythmias detected in human patients with iron overload may be the result of a complex interplay of factors.
Detection of Electrocardiogram by Electrodes with Fabrics Using Capacitive Coupling
NASA Astrophysics Data System (ADS)
Ueno, Akinori; Furusawa, Yoichi; Hoshino, Hiroshi; Ishiyama, Yoji
This article reports on a novel technique for detecting electrocardiogram (ECG) at a condition where thin cloth is interpolated between sensing electrodes and the skin to which the electrodes are attached. The technique is based upon capacitive coupling composed of the electrode, the cloth and the skin, so that the electrode can lead alternating electrocardiographic current through capacitance of the coupling. The technique is also founded on impedance transforming circuit that has extremely high input impedance around 1000GΩ and low output impedance, so as to match high output impedance of the electrode to low input impedance required by subsequent circuitry. A pilot ECG measuring device was manufactured using the technique and experiments showed (1) ECG recordings using the device with silk of 240μm thickness or with cotton of 564μm thickness were quite similar to ECGs recorded from the skin using conventional system, (2) stable ECGs were observed with the silk below 600μm thickness or with the cotton below 1128μm thickness, (3) effects of long-term measurement and perspiration on ECG waveform were negligible. These results prove feasibility of the proposed technique for detecting ECG by electrodes with fabrics.
Carrault, G; Cordier, M-O; Quiniou, R; Wang, F
2003-07-01
This paper proposes a novel approach to cardiac arrhythmia recognition from electrocardiograms (ECGs). ECGs record the electrical activity of the heart and are used to diagnose many heart disorders. The numerical ECG is first temporally abstracted into series of time-stamped events. Temporal abstraction makes use of artificial neural networks to extract interesting waves and their features from the input signals. A temporal reasoner called a chronicle recogniser processes such series in order to discover temporal patterns called chronicles which can be related to cardiac arrhythmias. Generally, it is difficult to elicit an accurate set of chronicles from a doctor. Thus, we propose to learn automatically from symbolic ECG examples the chronicles discriminating the arrhythmias belonging to some specific subset. Since temporal relationships are of major importance, inductive logic programming (ILP) is the tool of choice as it enables first-order relational learning. The approach has been evaluated on real ECGs taken from the MIT-BIH database. The performance of the different modules as well as the efficiency of the whole system is presented. The results are rather good and demonstrate that integrating numerical techniques for low level perception and symbolic techniques for high level classification is very valuable.
Koo, Ja Hoon; Jeong, Seongjin; Shim, Hyung Joon; Son, Donghee; Kim, Jaemin; Kim, Dong Chan; Choi, Suji; Hong, Jong-In; Kim, Dae-Hyeong
2017-10-24
With the rapid advances in wearable electronics, the research on carbon-based and/or organic materials and devices has become increasingly important, owing to their advantages in terms of cost, weight, and mechanical deformability. Here, we report an effective material and device design for an integrative wearable cardiac monitor based on carbon nanotube (CNT) electronics and voltage-dependent color-tunable organic light-emitting diodes (CTOLEDs). A p-MOS inverter based on four CNT transistors allows high amplification and thereby successful acquisition of the electrocardiogram (ECG) signals. In the CTOLEDs, an ultrathin exciton block layer of bis[2-(diphenylphosphino)phenyl]ether oxide is used to manipulate the balance of charges between two adjacent emission layers, bis[2-(4,6-difluorophenyl)pyridinato-C 2 ,N](picolinato)iridium(III) and bis(2-phenylquinolyl-N,C(2'))iridium(acetylacetonate), which thereby produces different colors with respect to applied voltages. The ultrathin nature of the fabricated devices supports extreme wearability and conformal integration of the sensor on human skin. The wearable CTOLEDs integrated with CNT electronics are used to display human ECG changes in real-time using tunable colors. These materials and device strategies provide opportunities for next generation wearable health indicators.
Spiva, LeeAnna; Johnson, Kimberly; Robertson, Bethany; Barrett, Darcy T; Jarrell, Nicole M; Hunter, Donna; Mendoza, Inocencia
2012-02-01
Historically, the instructional method of choice has been traditional lecture or face-to-face education; however, changes in the health care environment, including resource constraints, have necessitated examination of this practice. A descriptive pre-/posttest method was used to determine the effectiveness of alternative teaching modalities on nurses' knowledge and confidence in electrocardiogram (EKG) interpretation. A convenience sample of 135 nurses was recruited in an integrated health care system in the Southeastern United States. Nurses attended an instructor-led course, an online learning (e-learning) platform with no study time or 1 week of study time, or an e-learning platform coupled with a 2-hour post-course instructor-facilitated debriefing with no study time or 1 week of study time. Instruments included a confidence scale, an online EKG test, and a course evaluation. Statistically significant differences in knowledge and confidence were found for individual groups after nurses participated in the intervention. Statistically significant differences were found in pre-knowledge and post-confidence when groups were compared. Organizations that use various instructional methods to educate nurses in EKG interpretation can use different teaching modalities without negatively affecting nurses' knowledge or confidence in this skill. Copyright 2012, SLACK Incorporated.
Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Çiçek, Yüksel; Çetin, Mustafa; Duman, Hakan; Şatiroğlu, Ömer; Çelik, Şükrü
2017-03-01
Prolonged QRS duration is associated with decreased left ventricular (LV) systolic function. However, the relation between LV restrictive filling pattern (RFP) and QRS duration has not been investigated yet. The purpose of our study was to assess this relationship. We analyzed standard 12-lead surface electrocardiogram (ECG) of 155 consecutive patients. Mitral inflow and septal tissue velocities were obtained using the apical 4-chamber view with pulsed Doppler echocardiography. Patients were divided into 2 groups according to measured deceleration time (DT): restrictive (with DT ≤130 ms) or non-restrictive (with DT >130 ms). QRS duration was significantly longer in the restrictive group than in the non-restrictive group (0.101 vs. 0.090 s, p < 0.0001). QRS duration of >0.10 s was highly specific (82.6%), but modestly sensitive (64.7%), for the prediction of LV RFP. Multivariate analyses demonstrated that E/A ratio, peak E, peak A, septal e', and a' velocities were significantly associated with RFP. Prolonged QRS duration (>0.10 s) obtained from a standard resting 12-lead ECG is associated with LV RFP. However, the relationship of QRS duration with RFP was not independent of echocardiographic parameters.
The history, hotspots, and trends of electrocardiogram.
Yang, Xiang-Lin; Liu, Guo-Zhen; Tong, Yun-Hai; Yan, Hong; Xu, Zhi; Chen, Qi; Liu, Xiang; Zhang, Hong-Hao; Wang, Hong-Bo; Tan, Shao-Hua
2015-07-01
The electrocardiogram (ECG) has broad applications in clinical diagnosis and prognosis of cardiovascular disease. Many researchers have contributed to its progressive development. To commemorate those pioneers, and to better study and promote the use of ECG, we reviewed and present here a systematic introduction about the history, hotspots, and trends of ECG. In the historical part, information including the invention, improvement, and extensive applications of ECG, such as in long QT syndrome (LQTS), angina, and myocardial infarction (MI), are chronologically presented. New technologies and applications from the 1990s are also introduced. In the second part, we use the bibliometric analysis method to analyze the hotspots in the field of ECG-related research. By using total citations and year-specific total citations as our main criteria, four key hotspots in ECG-related research were identified from 11 articles, including atrial fibrillation, LQTS, angina and MI, and heart rate variability. Recent studies in those four areas are also reported. In the final part, we discuss the future trends concerning ECG-related research. The authors believe that improvement of the ECG instrumentation, big data mining for ECG, and the accuracy of diagnosis and application will be areas of continuous concern.
The normal electrocardiogram of four species of conscious raptors.
Talavera, J; Guzmán, M J; del Palacio, M J Fernández; Albert, A P; Bayón, A
2008-02-01
The aim of this study was to describe normal ECG patterns and values in four species of conscious raptors (Eurasian kestrel, Griffon vulture, Little owl, and Eurasian Eagle owl). Electrocardiograms were carried out in 75 conscious birds belonging to four species of raptors. Lead II waveforms were analysed to determine amplitudes and durations of waves and intervals. Morphologic patterns of P-QRS-T deflections were analysed in the six limb leads. Rhythm, heart rate, mean electrical axis, presence of Ta wave, ST slurring, and P-on-T phenomenon were also studied. The influence of species, body weight and heart rate in electrocardiographic variables were statistically analysed (P < 0.05). Sinus rhythm was present in all tracings, showing sinus arrhythmia in four cases. Ta wave was present in six tracings and P-on-T phenomenon in four. ST segment could be identified in all tracings, being mainly high above baseline. Significant differences between species were found for all the electrocardiographic parameters. The heart rate and body weight were also found to be a significant influence in most parameters. This study provides electrocardiographic data for four species of raptors that can be used to establish comparisons for clinical purposes.
Urtnasan, Erdenebayar; Park, Jong-Uk; Joo, Eun-Yeon; Lee, Kyoung-Joung
2018-04-23
In this study, we propose a method for the automated detection of obstructive sleep apnea (OSA) from a single-lead electrocardiogram (ECG) using a convolutional neural network (CNN). A CNN model was designed with six optimized convolution layers including activation, pooling, and dropout layers. One-dimensional (1D) convolution, rectified linear units (ReLU), and max pooling were applied to the convolution, activation, and pooling layers, respectively. For training and evaluation of the CNN model, a single-lead ECG dataset was collected from 82 subjects with OSA and was divided into training (including data from 63 patients with 34,281 events) and testing (including data from 19 patients with 8571 events) datasets. Using this CNN model, a precision of 0.99%, a recall of 0.99%, and an F 1 -score of 0.99% were attained with the training dataset; these values were all 0.96% when the CNN was applied to the testing dataset. These results show that the proposed CNN model can be used to detect OSA accurately on the basis of a single-lead ECG. Ultimately, this CNN model may be used as a screening tool for those suspected to suffer from OSA.
Urtnasan, Erdenebayar; Park, Jong-Uk; Lee, Kyoung-Joung
2018-05-24
In this paper, we propose a convolutional neural network (CNN)-based deep learning architecture for multiclass classification of obstructive sleep apnea and hypopnea (OSAH) using single-lead electrocardiogram (ECG) recordings. OSAH is the most common sleep-related breathing disorder. Many subjects who suffer from OSAH remain undiagnosed; thus, early detection of OSAH is important. In this study, automatic classification of three classes-normal, hypopnea, and apnea-based on a CNN is performed. An optimal six-layer CNN model is trained on a training dataset (45,096 events) and evaluated on a test dataset (11,274 events). The training set (69 subjects) and test set (17 subjects) were collected from 86 subjects with length of approximately 6 h and segmented into 10 s durations. The proposed CNN model reaches a mean -score of 93.0 for the training dataset and 87.0 for the test dataset. Thus, proposed deep learning architecture achieved a high performance for multiclass classification of OSAH using single-lead ECG recordings. The proposed method can be employed in screening of patients suspected of having OSAH. © 2018 Institute of Physics and Engineering in Medicine.
Heo, Jin-Chul; Kim, Beomjoon; Kim, Yoon-Nyun; Kim, Dae-Kwang; Lee, Jong-Ha
2017-01-01
Prolonged monitoring by cardiac electrocardiogram (ECG) sensors is useful for patients with emergency heart conditions. However, implant monitoring systems are limited by lack of tissue biocompatibility. Here, we developed an implantable ECG sensor for real-time monitoring of ventricular fibrillation and evaluated its biocompatibility using an animal model. The implantable sensor comprised transplant sensors with two electrodes, a wireless power transmission system, and a monitoring system. The sensor was inserted into the subcutaneous tissue of the abdominal area and operated for 1 h/day for 5 days using a wireless power system. Importantly, the sensor was encapsulated by subcutaneous tissue and induced angiogenesis, inflammation, and phagocytosis. In addition, we observed that the levels of inflammation-related markers increased with wireless-powered transmission via the ECG sensor; in particular, levels of the Th-1 cytokine interleukin-12 were significantly increased. The results showed that induced tissue damage was associated with the use of wireless-powered sensors. We also investigated research strategies for the prevention of adverse effects caused by lack of tissue biocompatibility of a wireless-powered ECG monitoring system and provided information on the clinical applications of inflammatory reactions in implant treatment using the wireless-powered transmission system. PMID:29240666
Measurements on wireless transmission of ECG signals
NASA Astrophysics Data System (ADS)
Gabrielli, A.; Lax, I.
2016-12-01
The scope of this research is to design an electronic prototype, an operative system as a proof of concept, to transmit and receive biological parameters, in particular electrocardiogram signals, through dedicated wireless circuits. The apparatus features microelectronics chips that were developed for more general biomedical applications, here adapted to deal with cardiac signals. The paper mainly focuses on the electronic aspects, as in this study we do not face medical or clinical aspects of the system. The transmitter circuit uses a commercial instrumentation amplifier and the receiver has been equipped with wide-band amplifiers along with made-in-the-lab band-pass filters centered at the carrier. We have been able to mount the entire system prototype into a preliminary data acquisition chain that reads out the electrocardiogram signal. The prototype allows acquiring the waveform, converting it to a digital pattern and open the transmission through a series of high-frequency packets exploiting the Ultra Wide Band protocol. The sensor value is embedded in the transmission through the rate of the digital packets. In fact, these are sent wireless at a specific packet-frequency that depends on the sensor amplitude and are detected into a receiver circuit that recovers the information.
A web-based approach for electrocardiogram monitoring in the home.
Magrabi, F; Lovell, N H; Celler, B G
1999-05-01
A Web-based electrocardiogram (ECG) monitoring service in which a longitudinal clinical record is used for management of patients, is described. The Web application is used to collect clinical data from the patient's home. A database on the server acts as a central repository where this clinical information is stored. A Web browser provides access to the patient's records and ECG data. We discuss the technologies used to automate the retrieval and storage of clinical data from a patient database, and the recording and reviewing of clinical measurement data. On the client's Web browser, ActiveX controls embedded in the Web pages provide a link between the various components including the Web server, Web page, the specialised client side ECG review and acquisition software, and the local file system. The ActiveX controls also implement FTP functions to retrieve and submit clinical data to and from the server. An intelligent software agent on the server is activated whenever new ECG data is sent from the home. The agent compares historical data with newly acquired data. Using this method, an optimum patient care strategy can be evaluated, a summarised report along with reminders and suggestions for action is sent to the doctor and patient by email.
Case report: an electrocardiogram of spontaneous pneumothorax mimicking arm lead reversal.
Wieters, J Scott; Carlin, Joseph P; Morris, Andrew
2014-05-01
There are several previously documented findings for electrocardiograms (ECGs) of spontaneous pneumothorax. These findings include axis deviation, T-wave inversion, and right bundle branch block. When an ECG has the arm leads incorrectly placed, the ECG will display right axis deviation and inversion of the P waves in lead I. There have been no previously published ECGs of spontaneous pneumothorax that have shown the same findings as reversal of the limb leads of an ECG. A possible finding of spontaneous pneumothorax is an identical finding to that of an ECG that has been flagged for limb lead reversal. A patient presented in the emergency setting with acute chest pain and shortness of breath caused by a tension pneumothorax. An ECG was administered; findings indicated reversal of the arm leads (right axis deviation and inverted P waves in lead I), but there was no actual limb lead reversal present. ECG findings resolved upon resolution of the pneumothorax. If a patient presents with chest pain and shortness of breath, and the patient's ECG is flagged for limb lead reversal despite being set up correctly, the physician should raise clinical suspicion for a possible spontaneous pneumothorax. Copyright © 2014 Elsevier Inc. All rights reserved.
The history, hotspots, and trends of electrocardiogram
Yang, Xiang-Lin; Liu, Guo-Zhen; Tong, Yun-Hai; Yan, Hong; Xu, Zhi; Chen, Qi; Liu, Xiang; Zhang, Hong-Hao; Wang, Hong-Bo; Tan, Shao-Hua
2015-01-01
The electrocardiogram (ECG) has broad applications in clinical diagnosis and prognosis of cardiovascular disease. Many researchers have contributed to its progressive development. To commemorate those pioneers, and to better study and promote the use of ECG, we reviewed and present here a systematic introduction about the history, hotspots, and trends of ECG. In the historical part, information including the invention, improvement, and extensive applications of ECG, such as in long QT syndrome (LQTS), angina, and myocardial infarction (MI), are chronologically presented. New technologies and applications from the 1990s are also introduced. In the second part, we use the bibliometric analysis method to analyze the hotspots in the field of ECG-related research. By using total citations and year-specific total citations as our main criteria, four key hotspots in ECG-related research were identified from 11 articles, including atrial fibrillation, LQTS, angina and MI, and heart rate variability. Recent studies in those four areas are also reported. In the final part, we discuss the future trends concerning ECG-related research. The authors believe that improvement of the ECG instrumentation, big data mining for ECG, and the accuracy of diagnosis and application will be areas of continuous concern. PMID:26345622
Dias, Andre; Franco, Emiliana; Martinez, Jasmine; Figueredo, Vincent M
A 38-year-old African American male patient with a past medical history of human immunodeficiency virus and schizophrenia who was noncompliant with medications presented to the emergency department (ED) after activation of the local crisis response center for altered mental status. Upon arrival he was lethargic and uncooperative, unable to provide any significant details apart from pleuritic chest pain. His blood pressure was 133/88 mmHg, heart rate 43 beats per minute and initial body temperature 36.1 °C which prompted an electrocardiogram (EKG). This initial EKG was compared to a prior one obtained six months earlier during an ER visit for an acute psychotic episode. Three hours of being admitted he started shivering. Patient was found to be hypothermic with a rectal temperature of 28.9 °C. He was also hypoglycemic, pancytopenic and had positive urine cultures with >100,000 CFU/ml coagulase-negative Staphylococcus. There was no evidence of medication overdose. His CT scan of the brain did not show evidence of intracranial bleeding and his serum calcium was normal. Copyright © 2017 Elsevier Inc. All rights reserved.
The 12-lead electrocardiogram and risk of sudden death: current utility and future prospects.
Narayanan, Kumar; Chugh, Sumeet S
2015-10-01
More than 100 years after it was first invented, the 12-lead electrocardiogram (ECG) continues to occupy an important place in the diagnostic armamentarium of the practicing clinician. With the recognition of relatively rare but important clinical entities such as Wolff-Parkinson-White and the long QT syndrome, this clinical tool was firmly established as a test for assessing risk of sudden cardiac death (SCD). However, over the past two decades the role of the ECG in risk prediction for common forms of SCD, for example in patients with coronary artery disease, has been the focus of considerable investigation. Especially in light of the limitations of current risk stratification approaches, there is a renewed focus on this broadly available and relatively inexpensive test. Various abnormalities of depolarization and repolarization on the ECG have been linked to SCD risk; however, more focused work is needed before they can be deployed in the clinical arena. The present review summarizes the current knowledge on various ECG risk markers for prediction of SCD and discusses some future directions in this field. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Exploring the Relationship Between Eye Movements and Electrocardiogram Interpretation Accuracy
NASA Astrophysics Data System (ADS)
Davies, Alan; Brown, Gavin; Vigo, Markel; Harper, Simon; Horseman, Laura; Splendiani, Bruno; Hill, Elspeth; Jay, Caroline
2016-12-01
Interpretation of electrocardiograms (ECGs) is a complex task involving visual inspection. This paper aims to improve understanding of how practitioners perceive ECGs, and determine whether visual behaviour can indicate differences in interpretation accuracy. A group of healthcare practitioners (n = 31) who interpret ECGs as part of their clinical role were shown 11 commonly encountered ECGs on a computer screen. The participants’ eye movement data were recorded as they viewed the ECGs and attempted interpretation. The Jensen-Shannon distance was computed for the distance between two Markov chains, constructed from the transition matrices (visual shifts from and to ECG leads) of the correct and incorrect interpretation groups for each ECG. A permutation test was then used to compare this distance against 10,000 randomly shuffled groups made up of the same participants. The results demonstrated a statistically significant (α 0.05) result in 5 of the 11 stimuli demonstrating that the gaze shift between the ECG leads is different between the groups making correct and incorrect interpretations and therefore a factor in interpretation accuracy. The results shed further light on the relationship between visual behaviour and ECG interpretation accuracy, providing information that can be used to improve both human and automated interpretation approaches.
A Precise Drunk Driving Detection Using Weighted Kernel Based on Electrocardiogram.
Wu, Chung Kit; Tsang, Kim Fung; Chi, Hao Ran; Hung, Faan Hei
2016-05-09
Globally, 1.2 million people die and 50 million people are injured annually due to traffic accidents. These traffic accidents cost $500 billion dollars. Drunk drivers are found in 40% of the traffic crashes. Existing drunk driving detection (DDD) systems do not provide accurate detection and pre-warning concurrently. Electrocardiogram (ECG) is a proven biosignal that accurately and simultaneously reflects human's biological status. In this letter, a classifier for DDD based on ECG is investigated in an attempt to reduce traffic accidents caused by drunk drivers. At this point, it appears that there is no known research or literature found on ECG classifier for DDD. To identify drunk syndromes, the ECG signals from drunk drivers are studied and analyzed. As such, a precise ECG-based DDD (ECG-DDD) using a weighted kernel is developed. From the measurements, 10 key features of ECG signals were identified. To incorporate the important features, the feature vectors are weighted in the customization of kernel functions. Four commonly adopted kernel functions are studied. Results reveal that weighted feature vectors improve the accuracy by 11% compared to the computation using the prime kernel. Evaluation shows that ECG-DDD improved the accuracy by 8% to 18% compared to prevailing methods.
Strauer, B E
1988-01-01
The clinical syndrome "coronary insufficience at normal coronary arteriogram" is found in approximately 10-20% of patients with exercise-induced coronary insufficience. In most of these cases disturbances of coronary microcirculation are present. They can appear in vascular diseases (arterial hypertension, systemic immunopathies, immune complex vasculitis, etc.), in rheological diseases (paraproteinemia, hyperlipoproteinemia, polyglobulia, etc.), and in disturbances of transport and diffusion of oxygen (carbon monoxide intoxication, methemoglobinemia, hyperlipoproteinemia). The clinical diagnosis is based on usual diagnostic programs (electrocardiogram, exercise electrocardiogram, responsiveness to nitroglycerin, etc.), as well as on newer, functionally orientated diagnostic procedures (determinations of coronary blood flow and of coronary vascular reserve, production of lactate, serological findings, histology and immune histology of peripheral arteries, measurements of viscosities in both plasma and blood, etc.). Many clinically relevant disturbances in coronary microcirculation can thus be detected and treated on a rational basis by the management of the internal main disease, that is, by the treatment of the vascular, rheological, and metabolic disorders. Persistent angina pectoris in the presence of normal coronary arteriogram represents no termination of coronary diagnostics, but moreover implies the clinical task for using diagnostic possibilities to enable functional and therapeutical assessment of coronary microcirculation.
Sparse electrocardiogram signals recovery based on solving a row echelon-like form of system.
Cai, Pingmei; Wang, Guinan; Yu, Shiwei; Zhang, Hongjuan; Ding, Shuxue; Wu, Zikai
2016-02-01
The study of biology and medicine in a noise environment is an evolving direction in biological data analysis. Among these studies, analysis of electrocardiogram (ECG) signals in a noise environment is a challenging direction in personalized medicine. Due to its periodic characteristic, ECG signal can be roughly regarded as sparse biomedical signals. This study proposes a two-stage recovery algorithm for sparse biomedical signals in time domain. In the first stage, the concentration subspaces are found in advance. Then by exploiting these subspaces, the mixing matrix is estimated accurately. In the second stage, based on the number of active sources at each time point, the time points are divided into different layers. Next, by constructing some transformation matrices, these time points form a row echelon-like system. After that, the sources at each layer can be solved out explicitly by corresponding matrix operations. It is noting that all these operations are conducted under a weak sparse condition that the number of active sources is less than the number of observations. Experimental results show that the proposed method has a better performance for sparse ECG signal recovery problem.
Yuceler, Zeyneb; Kantarci, Mecit; Yuce, Ihsan; Kizrak, Yesim; Bayraktutan, Ummugulsum; Ogul, Hayri; Kiris, Adem; Celik, Omer; Pirimoglu, Berhan; Genc, Berhan; Gundogdu, Fuat
2014-01-01
Our aim was to evaluate the diagnostic accuracy of 256-slice, high-pitch mode multidetector computed tomography (MDCT) for coronary artery bypass graft (CABG) patency. Eighty-eight patients underwent 256-slice MDCT angiography to evaluate their graft patency after CABG surgery using a prospectively synchronized electrocardiogram in the high-pitch spiral acquisition mode. Effective radiation doses were calculated. We investigated the diagnostic accuracy of high-pitch, low-dose, prospective, electrocardiogram-triggering, dual-source MDCT for CABG patency compared with catheter coronary angiography imaging findings. A total of 215 grafts and 645 vessel segments were analyzed. All graft segments had diagnostic image quality. The proximal and middle graft segments had significantly (P < 0.05) better mean image quality scores (1.18 ± 0.4) than the distal segments (1.31 ± 0.5). Using catheter coronary angiography as the reference standard, high-pitch MDCT had the following sensitivity, specificity, positive predictive value, and negative predictive value of per-segment analysis for detecting graft patency: 97.1%, 99.6%, 94.4%, and 99.8%, respectively. In conclusion, MDCT can be used noninvasively with a lower radiation dose for the assessment of restenosis in CABG patients.
Marcolino, Milena S; Carvalho, Bárbara C; Lucena, Aline M; França, Ana Luiza N; Pessoa, Cristiane G; Neves, Daniel S; Alkmim, Maria Beatriz M
2015-01-01
The Telehealth Network of Minas Gerais (TNMG) is a public telehealth service in Brazil that has performed electrocardiogram (ECG) analysis since 2005. From February to March 2014, 28% of ECGs were classified as "emergency" by the primary care tele-health sites. This quasi-experimental study aimed to investigate the reasons behind the high number of emergency ECGs being sent in, the implementation of corrective actions, and an assessment of the impact of these actions. In the 1st phase, primary care units that sent >70% of ECGs as emergency from February to March 2014 were selected. The 2nd phase consisted of the intervention. In the 3rd phase, the proportion of ECGs sent as an emergency during the 1st and 2nd months post intervention were assessed. Of the 63 cities selected during the 1st phase, 50% of the practitioners did not know the proper definition of emergency. After the intervention, 67% of the cities had a significant reduction in the proportion of ECGs sent as an emergency during the 1st month, and 17% had a significant reduction during the 2nd month.
Pant, Jeevan K; Krishnan, Sridhar
2014-04-01
A new algorithm for the reconstruction of electrocardiogram (ECG) signals and a dictionary learning algorithm for the enhancement of its reconstruction performance for a class of signals are proposed. The signal reconstruction algorithm is based on minimizing the lp pseudo-norm of the second-order difference, called as the lp(2d) pseudo-norm, of the signal. The optimization involved is carried out using a sequential conjugate-gradient algorithm. The dictionary learning algorithm uses an iterative procedure wherein a signal reconstruction and a dictionary update steps are repeated until a convergence criterion is satisfied. The signal reconstruction step is implemented by using the proposed signal reconstruction algorithm and the dictionary update step is implemented by using the linear least-squares method. Extensive simulation results demonstrate that the proposed algorithm yields improved reconstruction performance for temporally correlated ECG signals relative to the state-of-the-art lp(1d)-regularized least-squares and Bayesian learning based algorithms. Also for a known class of signals, the reconstruction performance of the proposed algorithm can be improved by applying it in conjunction with a dictionary obtained using the proposed dictionary learning algorithm.
Electrocardiogram signal denoising based on a new improved wavelet thresholding
NASA Astrophysics Data System (ADS)
Han, Guoqiang; Xu, Zhijun
2016-08-01
Good quality electrocardiogram (ECG) is utilized by physicians for the interpretation and identification of physiological and pathological phenomena. In general, ECG signals may mix various noises such as baseline wander, power line interference, and electromagnetic interference in gathering and recording process. As ECG signals are non-stationary physiological signals, wavelet transform is investigated to be an effective tool to discard noises from corrupted signals. A new compromising threshold function called sigmoid function-based thresholding scheme is adopted in processing ECG signals. Compared with other methods such as hard/soft thresholding or other existing thresholding functions, the new algorithm has many advantages in the noise reduction of ECG signals. It perfectly overcomes the discontinuity at ±T of hard thresholding and reduces the fixed deviation of soft thresholding. The improved wavelet thresholding denoising can be proved to be more efficient than existing algorithms in ECG signal denoising. The signal to noise ratio, mean square error, and percent root mean square difference are calculated to verify the denoising performance as quantitative tools. The experimental results reveal that the waves including P, Q, R, and S waves of ECG signals after denoising coincide with the original ECG signals by employing the new proposed method.
NASA Astrophysics Data System (ADS)
Mishra, Puneet; Singla, Sunil Kumar
2013-01-01
In the modern world of automation, biological signals, especially Electroencephalogram (EEG) and Electrocardiogram (ECG), are gaining wide attention as a source of biometric information. Earlier studies have shown that EEG and ECG show versatility with individuals and every individual has distinct EEG and ECG spectrum. EEG (which can be recorded from the scalp due to the effect of millions of neurons) may contain noise signals such as eye blink, eye movement, muscular movement, line noise, etc. Similarly, ECG may contain artifact like line noise, tremor artifacts, baseline wandering, etc. These noise signals are required to be separated from the EEG and ECG signals to obtain the accurate results. This paper proposes a technique for the removal of eye blink artifact from EEG and ECG signal using fixed point or FastICA algorithm of Independent Component Analysis (ICA). For validation, FastICA algorithm has been applied to synthetic signal prepared by adding random noise to the Electrocardiogram (ECG) signal. FastICA algorithm separates the signal into two independent components, i.e. ECG pure and artifact signal. Similarly, the same algorithm has been applied to remove the artifacts (Electrooculogram or eye blink) from the EEG signal.
Sidek, Khairul; Khali, Ibrahim
2012-01-01
In this paper, a person identification mechanism implemented with Cardioid based graph using electrocardiogram (ECG) is presented. Cardioid based graph has given a reasonably good classification accuracy in terms of differentiating between individuals. However, the current feature extraction method using Euclidean distance could be further improved by using Mahalanobis distance measurement producing extracted coefficients which takes into account the correlations of the data set. Identification is then done by applying these extracted features to Radial Basis Function Network. A total of 30 ECG data from MITBIH Normal Sinus Rhythm database (NSRDB) and MITBIH Arrhythmia database (MITDB) were used for development and evaluation purposes. Our experimentation results suggest that the proposed feature extraction method has significantly increased the classification performance of subjects in both databases with accuracy from 97.50% to 99.80% in NSRDB and 96.50% to 99.40% in MITDB. High sensitivity, specificity and positive predictive value of 99.17%, 99.91% and 99.23% for NSRDB and 99.30%, 99.90% and 99.40% for MITDB also validates the proposed method. This result also indicates that the right feature extraction technique plays a vital role in determining the persistency of the classification accuracy for Cardioid based person identification mechanism.
ST Elevation in AVR: When Time May Not Mean Muscle
2017-10-31
for Cardiovascular Angiography and Interventions (/) --1 m (/) ~ --1 ) • ::J CD z Q) 0 0... :J Q) I < (/) --1 ;a m ~ L..-. __ - c... disease in patients with non-ST-segment elevation acute coronary syndrome. Am J Cardiol 2011;107(4):495-500. • Smith SW. Updates on the electrocardiogram in acute coronary syndromes. Curr Emerg Hosp Med Rep 2012;1{1):43-52.
Active Authentication: Beyond Passwords
2011-11-18
103m 26-Jul-07 208k 27-Dec-10 4.9m Source: www.privacyrights.org/data-breach Hackers broke into a Gannett Co database containing personal...Pattern • Knuckle Pattern • Lip Pattern • Nail bed Pattern • Nose Pattern • Oto-acoustic Emissions • Palmprint • Retina Pattern • Skin... Palmprint Knuckle Pattern Pulse Electrocardiogram Electroencephalogram Face Geometry Lip Pattern Blue may be suitable for continuous monitoring
Hydatid cyst of the interventricular septum and contribution of magnetic resonance imaging.
Kulan, K; Tuncer, C; Kulan, C; Serce, K; Goldeli, O; Irhan, S; Komsuoglu, B
1995-01-01
Cardiac echinococcosis has not been reported frequently. Because of the risk of potentially lethal complications, early diagnosis and definitive treatment are very important. We report a case of a cardiac echinococcal cyst in the interventricular septum. The cyst that caused angina and showed ischemic changes in electrocardiogram was diagnosed by two-dimensional echocardiography and magnetic resonance imaging and was treated surgically.
NASA Technical Reports Server (NTRS)
1980-01-01
Lewis Research Center helped design the complex EMS Communication System, originating from space operated telemetry, including the telemetry link between ambulances and hospitals for advanced life support services. In emergency medical use telemetry links ambulances and hospitals for advanced life support services and allows transmission of physiological data -- an electrocardiogram from an ambulance to a hospital emergency room where a physician reads the telemetered message and prescribes emergency procedures to ambulance attendants.
Coleman wearing electrodes in the Node 1
2011-01-20
ISS026-E-018798 (20 Jan. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, is pictured in the Unity node of the International Space Station. Coleman is wearing electrodes, a Holter Monitor 2 (HM2) for recording Electrocardiogram (ECG), a European Space Agency (ESA) Cardio pressure / Blood Pressure unit to continuously monitor blood pressure and two Actiwatches (hip/waist and ankle) for monitoring activity levels.
A Novel Electrocardiogram Segmentation Algorithm Using a Multiple Model Adaptive Estimator
2002-03-01
2-5 Figure 2-3. Typical Pulse Oximeter Placement [20].....................................................2-5 Figure 2-4...the heart contracts and then decreases when the heart relaxes. The pulse oximeter is typically place on a toe, finger, or earlobe as shown in Figure...2-3. Figure 2-2. Absorption as Light Passes Through the Body [24]. Figure 2-3. Typical Pulse Oximeter Placement [19]. The pulse
2009-01-01
CBC, reticulocyte count, G-6-PD determination, Duffy phenotype, ABO and Rh group typing, hemoglobin electrophoresis and erythrocyte sedimentation ... rates and APTT† Cardiovascular disease Hepatic or renal abnormalities Cardiovascular function Immunodeficiency Electrocardiogram Autoimmune...malaria vaccine. Progress has been achieved in the development of P. vivax pre- erythrocytic subunit vaccines such as the circumsporo- zoite (CS) and
Brunetti, Natale Daniele; Dellegrottaglie, Giulia; Lopriore, Claudio; Di Giuseppe, Giuseppe; De Gennaro, Luisa; Lanzone, Saverio; Di Biase, Matteo
2014-03-01
Telemedicine has been shown to improve quality of health-care delivery in several fields of medicine; its cost-effectiveness, however, is still a matter of debate. Pre-hospital telemedicine electrocardiogram triage for regional public emergency medical service may reduce costs. An economic evaluation (cost analysis) was performed from the perspective of regional health-care system. Patients enrolled in the study and considered for cost analysis were those who called the local emergency medical service (EMS; dialing 1-1-8) during 2012 and underwent prehospital field triage with a telemedicine electrocardiogram (ECG) in the case of suspected acute cardiac disease (acute coronary syndrome, arrhythmia). The prehospital ECGs were read by a remote cardiologist, available 24/7. Cost savings associated with this method were calculated by subtracting the cost of prehospital triage with telemedicine support from the cost of conventional emergency department triage (ECG and consultation by a cardiologist). During 2012, the regional EMS performed 109 750 ECGs by telemedicine support. The associated total cost for the regional health-care system was €1 833 333, with a €16.70 cost per single ECG/consultation. Given the cost of similar conventional emergency department treatment from a regional rate list of €24.80 to €55.20, the savings was €8.10 to €38.40 per ECG/consultation (total savings, €891 759.50 to €4 219 379.50). The cost for ruling out an acute cardiac disease was €25.30; for a prehospital diagnosis of cardiovascular disease, €49.20. With 629 prehospital diagnoses of ST-elevation myocardial infarction and reported reductions in mortality thanks to prehospital diagnosis deduced from prior studies, 69 lives per year presumably could be saved, with a cost per quality-adjusted life year gained of €1927, €990/€ - 2508 after correction for potential savings. Prehospital EMS triage with telemedicine ECG in patients with suspected acute cardiac disease may reduce health-care costs. © 2014 Wiley Periodicals, Inc.
Takotsubo-like syndrome triggered by fludrocortisone overdose for Addison's disease: a case report.
Campean, Radu; Hasun, Matthias; Stöllberger, Claudia; Bucher, Johannes; Finsterer, Josef; Schnack, Christoph; Weidinger, Franz
2016-10-12
Reversible left ventricular dysfunction, also termed Takotsubo cardiomyopathy, is rarely reported in Addison's disease after initiation of hormone replacement therapy. The pathogenesis of this cardiomyopathy is unknown. A 41-year-old white woman with a history of autoimmune Hashimoto thyroiditis diagnosed 3 years earlier and acute adrenal insufficiency diagnosed 3 weeks earlier presented with new onset of heart failure New York Heart Association class IV, which had started shortly after initiation of hormone replacement therapy with hydrocortisone 20 mg/day and fludrocortisone 0.3 mg/day. Nine days before admission she had collapsed because of dizziness and had a cerebral concussion and open fracture of her nasal bone, however, no further investigations were carried out at that time. A physical examination revealed leg edema, tachycardia, tachypnea, bilateral basal crepitations, and blood pressure 110/70 mmHg. An electrocardiogram showed sinus tachycardia, low voltage, negative T-waves in V 5 and V 6 and a corrected QT interval of 590 ms. Echocardiography revealed a reduced left ventricular systolic function with an ejection fraction of 30 %, and septal, apical, and anterior wall akinesia. Cardiac magnetic resonance imaging showed relative enhancement of gadolinium, indicating hyperemia and capillary leakage, and no myocardial scars. Because of the improvement in her cardiac function, lack of cardiovascular risk factors, and lack of signs for ischemia on magnetic resonance imaging, no coronary angiography was carried out. The results of sellar and renal magnetic resonance imaging were normal. Her troponin T was slightly elevated. Bisoprolol and ramipril were started. Her fludrocortisone dose was reduced to 0.05 mg/day. Her electrocardiogram and systolic function, documented by echocardiography and magnetic resonance imaging, normalized within 6 months. Although we could not exclude coronary artery disease by coronary angiography, her clinical course and instrumental findings suggest Takotsubo cardiomyopathy of the apical type. Fludrocortisone overdosage and increased myocardial vulnerability due to cortisol deficiency might be pathogenetic factors, whereas myocarditis is unlikely. When hormone replacement in patients with Addison's disease is initiated, cardiac function should be monitored by electrocardiogram and echocardiography.
Ultrasound Monitoring of Jugular Venous Pulse during Space Missions: Proof of Concept.
Zamboni, Paolo; Sisini, Francesco; Menegatti, Erica; Taibi, Angelo; Gadda, Giacomo; Tavoni, Valentina; Malagoni, Anna Maria; Tessari, Mirko; Gianesini, Sergio; Gambaccini, Mauro
2018-03-01
The jugular venous pulse (JVP) is one of the main parameters of cardiac function and is used by cardiologists in diagnosing heart failure. Its waveform comprises three positive waves (a, c and v) and two negative waves (x and y). Recently, it was found that JVP can be extrapolated from an ultrasound (US) video recording of the internal jugular vein (IJV), suggesting its application in space missions, on which US scanners are already widely used. To date, the feasibility of assessing JVP in microgravity (microG) has not been investigated. To verify the feasibility of JVP assessment in microG, we tested a protocol of self-performed B-mode ultrasound on the International Space Station (ISS). The protocol consisted of a video recording of IJV synchronized with electrocardiogram that produces a cross-sectional area time trace (JVP trace) (in cm 2 ). The scans were acquired in six experimental sessions; two pre-flight (BDC1 and -2), two in space (ISS1 and -2) and two post-flight (Houston PF1, Cologne PF2). We measured the mean and standard deviation of the JVP waves and the phase relationship between such waves and P and T waves on the electrocardiogram. We verified that such parameters had the same accuracy on Earth as they did under microG, and we compared their values. The sensitivity, specificity and accuracy of JVP trace in microgravity are higher than those on Earth. The sequence of (a, c, and v) ascents and (x and y) descents along the cardiac cycle in microG is the same as that on Earth. The cause-and-effect relationship between the P and T waves on the electrocardiogram and a and v waves, respectively, of JVP is also confirmed in microG. Our experiment indicated the feasibility of deriving a JVP trace from a B-mode US examination self-performed by an astronaut in microG. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
Paratz, Elizabeth D; Zhao, Jessie; Sherwen, Amanda K; Scarlato, Rose-Marie; MacIsaac, Andrew I
2017-07-01
Methamphetamine use is escalating in Australia and New Zealand, with increasing emergency department attendance and mortality. Cardiac complications play a large role in methamphetamine-related mortality, and it would be informative to assess the frequency of abnormal electrocardiograms (ECGs) amongst methamphetamine users. To determine the frequency and severity of ECG abnormalities amongst methamphetamine users compared to a control group. We conducted a retrospective cohort analysis on 212 patients admitted to a tertiary hospital (106 patients with methamphetamine use, 106 age and gender-matched control patients). Electrocardiograms were analysed according to American College of Cardiology guidelines. Mean age was 33.4 years, with 73.6% male gender, with no significant differences between groups in smoking status, ECG indication, or coronary angiography rates. Methamphetamine users were more likely to have psychiatric admissions (22.6% vs 1.9%, p<0.0001). Overall, ECG abnormalities were significantly more common (71.7% vs 32.1%, p<0.0001) in methamphetamine users, particularly tachyarrhythmias (38.7% vs 26.4%, p<0.0001), right axis deviation (7.5% vs 0.0%, p=0.004), left ventricular hypertrophy (26.4% vs 4.7%, p<0.0001), P pulmonale pattern (7.5% vs 0.9%, p=0.017), inferior Q waves (10.4% vs 0.0%, p=0.001), lateral T wave inversion (3.8% vs 0.0%, p=0.043), and longer QTc interval (436.41±31.61ms vs 407.28±24.38ms, p<0.0001). Transthoracic echocardiogram (n=24) demonstrated left ventricular dysfunction (38%), thrombus (8%), valvular lesions (17%), infective endocarditis (17%), and pulmonary hypertension (13%). Electrocardiograms were only moderately sensitive at predicting abnormal TTE. Electrocardiographic abnormalities are more common in methamphetamine users than age and gender-matched controls. Due to the high frequency of abnormalities, ECGs should be performed in all methamphetamine users who present to hospital. Methamphetamine users with abnormal ECGs should undergo further cardiac investigations. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.
Analysis and Performance Evaluation of Electrocardiogram Data compression Techniques.
1980-12-01
techniques were investigated for potential real time implementation on an 8 bit Motorola 6800 microprocessor. Research indicated entropy reduction transform...EKG has been an area of active research since the late nineteen sixties. References (1) , (7) , (12) ,(26) ,(28) , (29) .(32) ,(33) , and (35) are...representative of the research efforts performed in the last ten years . The reasons for compressing EKG data are twofold: 1) digita" storage costs are
Occupational Survey Report. AFSC 4A2X1 Biomedical Equipment
2004-05-01
Electrocardiograms 70 Hospital Beds, Electric 67 Surgical Lamps 67 Hospital Beds, Manual 66 Audiometers 64 Dental Curing Units 63 Dental Handpieces 63...Pumps 78 Pulse Oximeters 78 Dental Chairs 76 Blood Pressure Monitors, Automatic 74 Examination Lamps 72 Examination Tables 72 Blood Pressure Cuffs 71...Exercise Bicycles 63 Dental Amalgamators 62 Scales or Balances, other than Pediatric 62 Scales or Balances, Pediatric 61 First-Enlistment Personnel
RIPPLE: Scalable Medical Telemetry System for Supporting Combat Rescue
2014-01-09
This reduces the burden of transporting multiple systems. For Ripple, we prototyped a system that combined a pulse oximeter , an electrocardiogram, a...o Nonin OEM III Module or Nonin XPOD Pulse Oximeters o Nonin 8000 series PureLight sensors o Shimmer Sensing ECG Board Identify applicable...equipment, e.g. pulse and respiration rate. Advances in wireless communications and miniaturization of electronics has led to the development and
[Citalopram, escitalopram and prolonged QT: warning or alarm?].
Alvarez, Enric; Vieira, Sara; Garcia-Moll, Xavier
2014-01-01
The alerts issued by regulatory agencies on the potential cardiac toxicity of citalopram and escitalopram have caused alarm among clinicians. A review of the data concerning this topic shows that the alarm should be limited to patients with a history of syncope or poisoning. As a precautionary measure, an electrocardiogram should be performed on elderly patients. Copyright © 2013 SEP y SEPB. Published by Elsevier España. All rights reserved.
2015-01-29
The Food and Drug Administration (FDA or the Agency) is issuing a final order to require the filing of premarket approval applications (PMA) for automated external defibrillator (AED) systems, which consist of an AED and those AED accessories necessary for the AED to detect and interpret an electrocardiogram and deliver an electrical shock (e.g., pad electrodes, batteries, adapters, and hardware keys for pediatric use).
2000-05-01
their annual visit. More than half the patients studied did not have periodic HbA1c testing, and one-third of the NIDDM patients did not have an...electrocardiogram and 44% to a registered dietitian. Fifty-seven percent of the records indicated only annual testing of HbA1c and 23% not being tested at
USAFSAM Review and Analysis of Radiofrequency Radiation Bioeffects Literature.
1981-11-01
less than 0.2 mW/cm . Clinical tests included ophthalmoscopic examination and a neurologic check-up supplemented by psychologic tests and EEG...34). These 12 studies are assessed individually and collectively below, followed by the analyses of each per se. Collective Summary In Lilienfeld et al...hours/workday). Electrocardiograms, heart and lung X-rays, eryth- rocyte sedimentation rates, urinalyses, and liver function tests were conducted as well
Medical Services: Medical Record Administration and Health Care Documentation
1999-05-03
prepared for each patient who must have one. (5) Ensure that a blood sample for deoxyribonucleic acid ( DNA ) identification is on file with the DNA ...degenerative joint disease DM diabetes mellitus DNA deoxyribonucleic acid DNR do not resuscitate DO Doctor of Osteopathy DOA dead on arrival DOB date...vein thrombosis DWI driving while intoxicated Dx diagnosis EBL estimated blood loss EBV Epstein-Barr virus ECG; EKG electrocardiogram E. coli
Microprocessor-based cardiotachometer
NASA Technical Reports Server (NTRS)
Crosier, W. G.; Donaldson, J. A.
1981-01-01
Instrument operates reliably even with stress-test electrocardiogram (ECG) signals subject to noise, baseline wandering, and amplitude change. It records heart rate from preamplified, single-lead ECG input signal and produces digital and analog heart-rate outputs which are fed elsewhere. Analog hardware processes ECG input signal, producing 10-ms pulse for each heartbeat. Microprocessor analyzes resulting pulse train, identifying irregular heartbeats and maintaining stable output during lead switching. Easily modified computer program provides analysis.
Skylab hardware report operational bioinstrumentation system
NASA Technical Reports Server (NTRS)
Luczkowski, S.
1977-01-01
The Skylab Operational Bioinstrumentation System is a personal, individually adjustable biomedical system designed to monitor the basic physiological functions of each suited crewman during specified periods of a manned space mission. The basic physiological functions of this system include electrocardiogram, respiration by impedance pneumogram, body temperature, cardiotachometer, and subject identification. The Operational Bioinstrumentation System was scheduled to monitor each crewman during launch, extravehicular activities, suited intravehicular experiments, and undocking and return.
2011-02-10
This practical pocket-book approach to electrocardiogram (ECG) interpretation accompanies Making sense of the eCg by the same authors. it is also designed to be used alone to test knowledge of ECG interpretation and to make clinical decisions based on presented scenarios.
The Use of Fuzzy Set Classification for Pattern Recognition of the Polygraph
1993-12-01
actual feature extraction was done, It was decided to use the K-nearest neighbor ( KNN ) the data was preprocessed. The electrocardiogram classifier in...showing heart pulse, and a low frequency not known beforehand, and the KNN classifier does not component showing blood volume. The derivative of...the characteristics of the conventional KNN these six derived signals were detrended and filtered, classification method is that it assigns each
Sub-chronic safety evaluation of the ethanol extract of Aralia elata leaves in Beagle dogs.
Li, Fengjin; He, Xiaoli; Niu, Wenying; Feng, Yuenan; Bian, Jingqi; Kuang, Haixue; Xiao, Hongbin
2016-08-01
Aralia elata Seem. (A. elata) is a traditional Chinese medicine to treat some diseases. This investigation aims to evaluate the pharmaceutical safety of the ethanol extract of A. elata leaves, namely ethanol leaves extract (ELE), in Beagle dogs. In sub-chronic oral toxicity study, dogs were treated with the ELE at doses of 50, 100 and 200 mg/kg for 12 weeks and followed by 4 weeks recovery period. During experimental period, clinical signs, mortality, body temperature, food consumption and body weight were recorded. Analysis of electrocardiogram, urinalysis, ophthalmoscopy, hematology, serum biochemistry, organ weights and histopathology were performed. The results showed that both food consumption and body weight significantly decreased in high-dose group. Treatment-related side effects and mortality were observed in high-dose female dogs. Some parameters showed significant alterations in electrocardiogram, urinalysis, serum biochemistry and relative organ weights. These alterations were not related to dose or consistent across gender, which were ascribed to incidental and biological variability. The findings in this study indicated that the no-observed adverse effect level (NOAEL) of the ELE was 100 mg/kg in dogs and provided a vital reference for selecting a safe application dosage for human consumption. Copyright © 2016 Elsevier Inc. All rights reserved.
A systematic review of prenatal screening for congenital heart disease by fetal electrocardiography.
Verdurmen, Kim M J; Eijsvoogel, Noortje B; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; van Laar, Judith O E H; Oei, S Guid
2016-11-01
Congenital heart disease (CHD) is the most common severe congenital anomaly worldwide. Diagnosis early in pregnancy is important, but the detection rate by two-dimensional ultrasonography is only 65%-81%. To evaluate existing data on CHD and noninvasive abdominal fetal electrocardiography (ECG). A systematic review was performed through a search of the Cochrane Library, PubMed, and Embase for studies published up to April 2016 using the terms "congenital heart disease," "fetal electrocardiogram," and other similar keywords. Primary articles that described changes in fetal ECG among fetuses with CHD published in English were included. Outcomes of interest were changes in fetal ECG parameters observed for fetuses with congenital heart disease. Findings were reported descriptively. Only five studies described changes observed in the fetal electrocardiogram for fetuses with CHD, including heart rate, heart rate variability, and PR, QRS, and QT intervals. Fetal ECG reflects the intimate relationship between the cardiac nerve conduction system and the structural morphology of the heart. It seems particularly helpful in detecting the electrophysiological effects of cardiac anatomic defects (e.g. hypotrophy, hypertrophy, and conduction interruption). Fetal ECG might be a promising clinical tool to complement ultrasonography in the screening program for CHD. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Nayan, Nazrul Anuar; Risman, Nur Sabrina; Jaafar, Rosmina
2016-07-27
Among vital signs of acutely ill hospital patients, respiratory rate (RR) is a highly accurate predictor of health deterioration. This study proposes a system that consists of a passive and non-invasive single-lead electrocardiogram (ECG) acquisition module and an ECG-derived respiratory (EDR) algorithm in the working prototype of a mobile application. Before estimating RR that produces the EDR rate, ECG signals were evaluated based on the signal quality index (SQI). The SQI algorithm was validated quantitatively using the PhysioNet/Computing in Cardiology Challenge 2011 training data set. The RR extraction algorithm was validated by adopting 40 MIT PhysioNet Multiparameter Intelligent Monitoring in Intensive Care II data set. The estimated RR showed a mean absolute error (MAE) of 1.4 compared with the ``gold standard'' RR. The proposed system was used to record 20 ECGs of healthy subjects and obtained the estimated RR with MAE of 0.7 bpm. Results indicate that the proposed hardware and algorithm could replace the manual counting method, uncomfortable nasal airflow sensor, chest band, and impedance pneumotachography often used in hospitals. The system also takes advantage of the prevalence of smartphone usage and increase the monitoring frequency of the current ECG of patients with critical illnesses.
Bhaumik, Basabi
2016-01-01
A novel algorithm based on forward search is developed for real-time electrocardiogram (ECG) signal processing and implemented in application specific integrated circuit (ASIC) for QRS complex related cardiovascular disease diagnosis. The authors have evaluated their algorithm using MIT-BIH database and achieve sensitivity of 99.86% and specificity of 99.93% for QRS complex peak detection. In this Letter, Physionet PTB diagnostic ECG database is used for QRS complex related disease detection. An ASIC for cardiovascular disease detection is fabricated using 130-nm CMOS high-speed process technology. The area of the ASIC is 0.5 mm2. The power dissipation is 1.73 μW at the operating frequency of 1 kHz with a supply voltage of 0.6 V. The output from the ASIC is fed to their Android application that generates diagnostic report and can be sent to a cardiologist through email. Their ASIC result shows average failed detection rate of 0.16% for six leads data of 290 patients in PTB diagnostic ECG database. They also have implemented a low-leakage version of their ASIC. The ASIC dissipates only 45 pJ with a supply voltage of 0.9 V. Their proposed ASIC is most suitable for energy efficient telemetry cardiovascular disease detection system. PMID:27284458
Marcomichelakis, J; Donaldson, R; Green, J; Joseph, S; Kelly, H B; Taggart, P; Somerville, W
1980-01-01
The value of exercise testing in detecting myocardial ischaemia resulting from coronary atheroma remains controversial. In order to increase the reliability of exercise testing, all its components (asymptomatic, haemodynamic, and electrocardiographic) have been scrutinised. In this study, concerned only with the electrocardiographic response to exercise, the incorporation of beta-blockade into the standard exercise procedure has improved specificity and predictive value without affecting sensitivity. Fifty patients with anginal pain and 50 asymptomatic subjects with an abnormal electrocardiogram were investigated by exercise testing before and after beta-blockade (oxprenolol). All subjects had coronary arteriograms and left ventriculograms, and the results of exercise testing were related to the presence or absence of obstructive coronary artery disease. Possible causes of false positive exercise tests were eliminated by echocardiography. Though beta-blockade was unreliable in distinguishing ischaemic from non-ischaemic resting electrocardiograms, it eliminated all the false positive electrocardiographic responses to exercise in both groups and did not abolish any of the true positive electrocardiographic responses. Thus, specificity and predictive value were improved without reduction in sensitivity. This technique may not necessarily be applicable to other groups of patients or to a random population, but the results of this study suggest it will be a useful additional routine procedure in the investigation of coronary heart disease. PMID:7437172
Wind, Jentina; van Mook, Walther N K A; Dhanani, Sonny; van Heurn, Ernest W L
2016-02-01
Determination of death is an essential part of donation after circulatory death (DCD). We studied the current practices of determination of death after circulatory arrest by intensive care physicians in the Netherlands, the availability of guidelines, and the occurrence of the phenomenon of autoresuscitation. The Determination of Cardiac Death Practices in Intensive Care Survey was sent to all intensive care physicians. Fifty-five percent of 568 Dutch intensive care physicians responded. Most respondents learned death determination from clinical practice. The most commonly used tests for death determination were flat arterial line tracing, flat electrocardiogram (standard 3-lead electrocardiogram), and fixed and dilated pupils. Rarely used tests were absence pulse by echo Doppler, absent blood pressure by noninvasive monitoring, and unresponsiveness to painful stimulus. No diagnostic test or procedure was uniformly performed, but 80% of respondents perceived a need for standardization of death determination. Autoresuscitation was witnessed by 37%, after withdrawal of treatment or after unsuccessful resuscitation. Extensive variability in the practice of determining death after circulatory arrest exists, and a need for guidelines and standardization, especially if organ donation follows death, is reported. Autoresuscitation is reported; this observation requires attention in further prospective observational studies. Copyright © 2015 Elsevier Inc. All rights reserved.
Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Çiçek, Yüksel; Çetin, Mustafa; Duman, Hakan; Şatiroğlu, Ömer; Çelik, Şükrü
2017-01-01
Background Prolonged QRS duration is associated with decreased left ventricular (LV) systolic function. However, the relation between LV restrictive filling pattern (RFP) and QRS duration has not been investigated yet. The purpose of our study was to assess this relationship. Methods We analyzed standard 12-lead surface electrocardiogram (ECG) of 155 consecutive patients. Mitral inflow and septal tissue velocities were obtained using the apical 4-chamber view with pulsed Doppler echocardiography. Patients were divided into 2 groups according to measured deceleration time (DT): restrictive (with DT ≤130 ms) or non-restrictive (with DT >130 ms). Results QRS duration was significantly longer in the restrictive group than in the non-restrictive group (0.101 vs. 0.090 s, p < 0.0001). QRS duration of >0.10 s was highly specific (82.6%), but modestly sensitive (64.7%), for the prediction of LV RFP. Multivariate analyses demonstrated that E/A ratio, peak E, peak A, septal e’, and a’ velocities were significantly associated with RFP. Conclusions Prolonged QRS duration (>0.10 s) obtained from a standard resting 12-lead ECG is associated with LV RFP. However, the relationship of QRS duration with RFP was not independent of echocardiographic parameters. PMID:28932490
Matched Filtering for Heart Rate Estimation on Compressive Sensing ECG Measurements.
Da Poian, Giulia; Rozell, Christopher J; Bernardini, Riccardo; Rinaldo, Roberto; Clifford, Gari D
2017-09-14
Compressive Sensing (CS) has recently been applied as a low complexity compression framework for long-term monitoring of electrocardiogram signals using Wireless Body Sensor Networks. Long-term recording of ECG signals can be useful for diagnostic purposes and to monitor the evolution of several widespread diseases. In particular, beat to beat intervals provide important clinical information, and these can be derived from the ECG signal by computing the distance between QRS complexes (R-peaks). Numerous methods for R-peak detection are available for uncompressed ECG. However, in case of compressed sensed data, signal reconstruction can be performed with relatively complex optimisation algorithms, which may require significant energy consumption. This article addresses the problem of hearth rate estimation from compressive sensing electrocardiogram (ECG) recordings, avoiding the reconstruction of the entire signal. We consider a framework where the ECG signals are represented under the form of CS linear measurements. The QRS locations are estimated in the compressed domain by computing the correlation of the compressed ECG and a known QRS template. Experiments on actual ECG signals show that our novel solution is competitive with methods applied to the reconstructed signals. Avoiding the reconstruction procedure, the proposed method proves to be very convenient for real-time, low-power applications.
Accuracy of electrocardiogram reading by family practice residents.
Sur, D K; Kaye, L; Mikus, M; Goad, J; Morena, A
2000-05-01
This study evaluated the electrocardiogram (EKG) reading skills of family practice residents. A multicenter study was carried out to evaluate the accuracy of EKG reading in the family practice setting. Based on the frequency and potential for clinical significance, we chose 18 common findings on 10 EKGs for evaluation. The EKGs were then distributed to residents at six family practice residencies. Residents were given one point for the identification of each correct EKG finding and scored based on the number correct over a total of 18. Sixty-one residents (20 first year, 23 second year, and 18 third year) completed readings for 10 EKGs and were evaluated for their ability to identify 18 EKG findings. The median score out of 18 possible points for all first-, second-, and third-year residents was 12, 12, and 11.5, respectively. Twenty-one percent of residents did not correctly identify a tracing of an acute myocardial infarction. Data analysis showed no statistically significant difference among the three groups of residents. We evaluated the accuracy of EKG reading skills of family practice residents at each year of training. This study suggests that EKG reading skills do not improve during residency, and further study of curricular change to improve these skills should be considered.
A Fixed-Lag Kalman Smoother to Filter Power Line Interference in Electrocardiogram Recordings.
Warmerdam, G J J; Vullings, R; Schmitt, L; Van Laar, J O E H; Bergmans, J W M
2017-08-01
Filtering power line interference (PLI) from electrocardiogram (ECG) recordings can lead to significant distortions of the ECG and mask clinically relevant features in ECG waveform morphology. The objective of this study is to filter PLI from ECG recordings with minimal distortion of the ECG waveform. In this paper, we propose a fixed-lag Kalman smoother with adaptive noise estimation. The performance of this Kalman smoother in filtering PLI is compared to that of a fixed-bandwidth notch filter and several adaptive PLI filters that have been proposed in the literature. To evaluate the performance, we corrupted clean neonatal ECG recordings with various simulated PLI. Furthermore, examples are shown of filtering real PLI from an adult and a fetal ECG recording. The fixed-lag Kalman smoother outperforms other PLI filters in terms of step response settling time (improvements that range from 0.1 to 1 s) and signal-to-noise ratio (improvements that range from 17 to 23 dB). Our fixed-lag Kalman smoother can be used for semi real-time applications with a limited delay of 0.4 s. The fixed-lag Kalman smoother presented in this study outperforms other methods for filtering PLI and leads to minimal distortion of the ECG waveform.
Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement.
Lee, Seung Min; Sim, Kyo Sik; Kim, Ko Keun; Lim, Yong Gyu; Park, Kwang Suk
2010-05-01
Capacitive electrocardiogram (ECG) measurement over clothing requires large electrodes that can remain in contact with curved body surfaces to increase the signal-to-noise ratio (SNR). In this article, we propose a new, thin, and flexible active electrode for use as a capacitive ECG measurement electrode. This electrode contains a shielding plate over its surface and it is extremely thin and can bend freely to cover larger body surfaces of the curve-shaped human torso. We evaluated the characteristics of flexible active electrodes under conditions of varying cloth thickness, electrode size, and contacting pressure. Electrodes of two sizes (45 and 12 cm(2)) were attached to a chest belt to measure the ECG from the human torso, and the results obtained for both the sizes were compared. Cloth thickness and electrode size showed a dominant effect on the SNR, whereas contacting pressure had almost no effect. The flexible active electrodes attached to chest belts wrapped closely and uniformly over the curved surface of the torso and SNR was increased with an increase in electrode size. Although the ECG signal became more distorted as the cloth thickness increased, the larger-sized flexible active electrode (45 cm(2)) showed less distortion than the smaller-sized one (12 cm(2)).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, C.-H.; Chen, C.-L.; Hsiao, C.K.
2009-09-15
Chronic arsenic exposure has been documented to be associated with various cardiovascular diseases. We aimed to investigate 1) the increased risk of QT prolongation in chronic arsenic exposure, and 2) the relationships of cardiac repolarization (QT interval duration) with ischemic heart disease and carotid atherosclerosis. We studied 280 men and 355 women living in the endemic area of arseniasis in southwestern Taiwan. QT intervals in electrocardiogram and carotid intima-media thickness (IMT) by ultrasonography were measured. Ischemic heart disease was diagnosed by history or abnormal electrocardiogram. Significant associations of the corrected QT interval (QTc) duration with ischemic heart disease and carotidmore » intima-medium thickness and plaque were observed after adjustment for various risk factors in the multiple linear regression analysis (all p values < 0.05). Three indices of chronic arsenic exposure were all significantly associated with the risk of QTc prolongation showing dose-response relationships (p < 0.001). Chronic arsenic exposure was dose-dependently associated with the risk of QTc prolongation. Ischemic heart disease and carotid atherosclerosis were significantly associated with QTc intervals in chronic arsenic exposure. QTc prolongation might be suggested as an early biomarker for ischemic heart disease or carotid atherosclerosis in population with previous exposure to arsenic.« less
Envelopment filter and K-means for the detection of QRS waveforms in electrocardiogram.
Merino, Manuel; Gómez, Isabel María; Molina, Alberto J
2015-06-01
The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper describes an offline version and a real-time implementation of a new algorithm to determine QRS localization in the ECG signal based on its envelopment and K-means clustering algorithm. The envelopment is used to obtain a signal with only QRS complexes, deleting P, T, and U waves and baseline wander. Two moving average filters are applied to smooth data. The K-means algorithm classifies data into QRS and non-QRS. The technique is validated using 22 h of ECG data from five Physionet databases. These databases were arbitrarily selected to analyze different morphologies of QRS complexes: three stored data with cardiac pathologies, and two had data with normal heartbeats. The algorithm has a low computational load, with no decision thresholds. Furthermore, it does not require any additional parameter. Sensitivity, positive prediction and accuracy from results are over 99.7%. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Jain, Sanjeev Kumar; Bhaumik, Basabi
2016-03-01
A novel algorithm based on forward search is developed for real-time electrocardiogram (ECG) signal processing and implemented in application specific integrated circuit (ASIC) for QRS complex related cardiovascular disease diagnosis. The authors have evaluated their algorithm using MIT-BIH database and achieve sensitivity of 99.86% and specificity of 99.93% for QRS complex peak detection. In this Letter, Physionet PTB diagnostic ECG database is used for QRS complex related disease detection. An ASIC for cardiovascular disease detection is fabricated using 130-nm CMOS high-speed process technology. The area of the ASIC is 0.5 mm(2). The power dissipation is 1.73 μW at the operating frequency of 1 kHz with a supply voltage of 0.6 V. The output from the ASIC is fed to their Android application that generates diagnostic report and can be sent to a cardiologist through email. Their ASIC result shows average failed detection rate of 0.16% for six leads data of 290 patients in PTB diagnostic ECG database. They also have implemented a low-leakage version of their ASIC. The ASIC dissipates only 45 pJ with a supply voltage of 0.9 V. Their proposed ASIC is most suitable for energy efficient telemetry cardiovascular disease detection system.
Weaver, James C; Rees, David; Prasan, Ananth M; Ramsay, David D; Binnekamp, Maurits F; McCrohon, Jane A
2011-01-01
Grade 3 ischemia during ST elevation myocardial infarction (STEMI) is defined as ST elevation with distortion of the terminal portion of the QRS on electrocardiogram (ECG). The aim of this study was to evaluate the effect of ischemic grade on cardiac magnetic resonance (CMR) imaging infarct characteristics such as infarct size, microvascular obstruction (MVO), intramyocardial hemorrhage (IMH), and myocardial salvage. Patients with STEMI treated with primary percutaneous coronary intervention had a 12-lead ECG on presentation for analysis of ischemic grade. Gadolinium-enhanced CMR imaging was performed within 7 days to assess infarct size, MVO, IMH, and myocardial salvage. Of the 37 patients enrolled in the study, grade 3 ischemia was present in 32%. Those with grade 3 ischemia had higher peak troponin I levels (P = .013), more MVO (P < .001), more IMH (P < .001), larger infarct size (P = .025), and less myocardial salvage (P = .012). Regression analysis found that grade 3 ischemia, infarct size, and peak troponin I level were significantly associated with MVO and IMH. Grade 3 ischemia on the admission ECG during STEMI is closely associated with the development of severe microvascular damage on CMR imaging. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Boudaoud, S.; Rix, H.; Meste, O.; Heneghan, C.; O'Brien, C.
2007-12-01
We present a technique called corrected integral shape averaging (CISA) for quantifying shape and shape differences in a set of signals. CISA can be used to account for signal differences which are purely due to affine time warping (jitter and dilation/compression), and hence provide access to intrinsic shape fluctuations. CISA can also be used to define a distance between shapes which has useful mathematical properties; a mean shape signal for a set of signals can be defined, which minimizes the sum of squared shape distances of the set from the mean. The CISA procedure also allows joint estimation of the affine time parameters. Numerical simulations are presented to support the algorithm for obtaining the CISA mean and parameters. Since CISA provides a well-defined shape distance, it can be used in shape clustering applications based on distance measures such as[InlineEquation not available: see fulltext.]-means. We present an application in which CISA shape clustering is applied to P-waves extracted from the electrocardiogram of subjects suffering from sleep apnea. The resulting shape clustering distinguishes ECG segments recorded during apnea from those recorded during normal breathing with a sensitivity of[InlineEquation not available: see fulltext.] and specificity of[InlineEquation not available: see fulltext.].
An ambulatory recording system for the assessment of autonomic changes across multiple days
NASA Astrophysics Data System (ADS)
Sollers, John J., III; Yonezawa, Yoshiharu; Silver, Rebecca A.; Merritt, Marcellus M.; Thayer, Julian F.
2005-05-01
Recent evidence indicates that poor autonomic regulation, indexed by decreased heart period variability (HPV), is associated with decreased working memory. HPV analyses are computed on the interbeat interval time series derived from the electrocardiogram (EKG). Unfortunately, the duration of the data collection and the issue of the size of ambulatory monitors with sufficient storage capacity for multi-day records is somewhat problematic. In the present paper we describe a system that allows for the collection of large amounts of high quality data using a small data collection device. The recording system consists of a miniature, single-module electrocardiogram-recording device. This module consists of an integrated three-electrode device that is attached to the chest of the subject. A low power 8-bit micro-controller detects the R-spike and stores the time between R-spikes in milliseconds on a 512 KB EEPROM. This system can record continuously for over four days. This system will allow the recording of cardio-dynamics in the field and provide highly reliable data across multiple days. The use of this device to assess physiological function in military operations would allow researchers to examine longer data records across several contexts and to understand the role of changes in autonomic function as they relate to performance.
Nonlinear time series analysis of electrocardiograms
NASA Astrophysics Data System (ADS)
Bezerianos, A.; Bountis, T.; Papaioannou, G.; Polydoropoulos, P.
1995-03-01
In recent years there has been an increasing number of papers in the literature, applying the methods and techniques of Nonlinear Dynamics to the time series of electrical activity in normal electrocardiograms (ECGs) of various human subjects. Most of these studies are based primarily on correlation dimension estimates, and conclude that the dynamics of the ECG signal is deterministic and occurs on a chaotic attractor, whose dimension can distinguish between healthy and severely malfunctioning cases. In this paper, we first demonstrate that correlation dimension calculations must be used with care, as they do not always yield reliable estimates of the attractor's ``dimension.'' We then carry out a number of additional tests (time differencing, smoothing, principal component analysis, surrogate data analysis, etc.) on the ECGs of three ``normal'' subjects and three ``heavy smokers'' at rest and after mild exercising, whose cardiac rhythms look very similar. Our main conclusion is that no major dynamical differences are evident in these signals. A preliminary estimate of three to four basic variables governing the dynamics (based on correlation dimension calculations) is updated to five to six, when temporal correlations between points are removed. Finally, in almost all cases, the transition between resting and mild exercising seems to imply a small increase in the complexity of cardiac dynamics.
Wang, Qiguang; Zhu, Xianyang; Duanzhen, Zhang; Zhang, Po; Chen, Huoyuan; Han, Xiumin; Sheng, Xiaotang; Meng, Lili
2017-06-01
This study aims to assess the clinical efficiency and safety of simultaneous transcatheter interventional treatment for perimembranous ventricular septal defect (pmVSD) combined with patent ductus arteriosus (PDA). Twenty-five patients with pmVSD and PDA treated with simultaneous transcatheter interventions from April 2004 to December 2015 were included in this study. The mean age was 9.80 ± 8.14 years and the mean weight was 29.76 ± 14.82 Kg. Transthoracic echocardiography (TTE) and angiography were performed immediately after the procedure. Patients were re-examined by electrocardiogram, X-ray, and TTE at 2 days, 1 month, 3 months, and 6 months postoperatively. The interventional procedure was successfully performed in all 25 patients. No intraoperative complication was noted. TTE examination of the VSD and PDA immediately after the procedure showed no residual shunt and the occluder was well positioned. Among these patients, four patients showed electrocardiogram changes after the procedure that resolved after drug therapy. The cardiothoracic ratio, left atrial diameter, left ventricular end-systolic diameter, and left ventricular end-diastolic diameter recovered to normal in most patients at 6 months postoperatively. Simultaneously transcatheter interventional therapy is a safe and effective method for pmVSD combined with PDA. © 2017 Wiley Periodicals, Inc.
Hayashi, Risa; Nakai, Kenji; Fukushima, Akimune; Itoh, Manabu; Sugiyama, Toru
2009-03-01
Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.
Mahdavi, Naser
2014-01-01
In light of the popularity and also the various nutritional and medicinal properties of Berberis integerrima, this study was conducted to assess the influence of its aqueous extract on hemodynamic and electrocardiogram (ECG) indices of rat. Animals were divided to control (CTL), B50, B100, and B200 groups that orally received tap water, aqueous extracts of B. integerrima fruit 50, 100, and 200 mg/kg/day, respectively, for two weeks and on day 15, data were recorded. Different doses of barberry fruit extract had no significant effect on blood pressure, heart rate, RR interval, P duration, and Q wave amplitude of electrocardiogram. Extract administration was associated with an incremental trend in PR interval that was not statistically significant. Higher doses (100 and 200 mg/kg) of extract significantly increased the QRS interval (P < 0.01 versus CTL and B50 groups) but decreased the QTc interval (P < 0.01 versus CTL group and P < 0.001 versus B50 group), the JT interval, and TpTe interval (P < 0.001 versus CTL and B50 groups). The results suggest that high doses of barberry extract definitely prolong the depolarization phase and shorten the repolarization phase of ventricular muscle and hence induce alteration in heart electrical conductivity. PMID:27351000
Shen, Wenfeng; Wei, Daming; Xu, Weimin; Zhu, Xin; Yuan, Shizhong
2010-10-01
Biological computations like electrocardiological modelling and simulation usually require high-performance computing environments. This paper introduces an implementation of parallel computation for computer simulation of electrocardiograms (ECGs) in a personal computer environment with an Intel CPU of Core (TM) 2 Quad Q6600 and a GPU of Geforce 8800GT, with software support by OpenMP and CUDA. It was tested in three parallelization device setups: (a) a four-core CPU without a general-purpose GPU, (b) a general-purpose GPU plus 1 core of CPU, and (c) a four-core CPU plus a general-purpose GPU. To effectively take advantage of a multi-core CPU and a general-purpose GPU, an algorithm based on load-prediction dynamic scheduling was developed and applied to setting (c). In the simulation with 1600 time steps, the speedup of the parallel computation as compared to the serial computation was 3.9 in setting (a), 16.8 in setting (b), and 20.0 in setting (c). This study demonstrates that a current PC with a multi-core CPU and a general-purpose GPU provides a good environment for parallel computations in biological modelling and simulation studies. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
A new statistical PCA-ICA algorithm for location of R-peaks in ECG.
Chawla, M P S; Verma, H K; Kumar, Vinod
2008-09-16
The success of ICA to separate the independent components from the mixture depends on the properties of the electrocardiogram (ECG) recordings. This paper discusses some of the conditions of independent component analysis (ICA) that could affect the reliability of the separation and evaluation of issues related to the properties of the signals and number of sources. Principal component analysis (PCA) scatter plots are plotted to indicate the diagnostic features in the presence and absence of base-line wander in interpreting the ECG signals. In this analysis, a newly developed statistical algorithm by authors, based on the use of combined PCA-ICA for two correlated channels of 12-channel ECG data is proposed. ICA technique has been successfully implemented in identifying and removal of noise and artifacts from ECG signals. Cleaned ECG signals are obtained using statistical measures like kurtosis and variance of variance after ICA processing. This analysis also paper deals with the detection of QRS complexes in electrocardiograms using combined PCA-ICA algorithm. The efficacy of the combined PCA-ICA algorithm lies in the fact that the location of the R-peaks is bounded from above and below by the location of the cross-over points, hence none of the peaks are ignored or missed.
Premature Ventricular Complexes on Screening Electrocardiogram and Risk of Ischemic Stroke
Agarwal, Sunil K.; Chao, Jennifer; Peace, Frederick; Judd, Suzanne E.; Kissela, Brett; Kleindorfer, Dawn; Howard, Virginia J.; Howard, George; Soliman, Elsayed Z.
2015-01-01
Background and Purpose Premature ventricular complexes (PVCs) detected from long-term electrocardiogram (ECG) recordings have been associated with an increased risk of ischemic stroke. Whether PVCs seen on routine ECG, commonly used in clinical practice, are associated with an increased risk of ischemic stroke remains unstudied. Methods This analysis included 24,460 participants (age 64.5+9.3 years, 55.1% Female, 40.0% African Americans) from the REasons for Geographic And Racial Differences in Stroke (REGARDS) study who were free of stroke at the time of enrollment. PVCs were ascertained from baseline ECG (2003-2007), and incident stroke cases through 2011 were confirmed by an adjudication committee. Results A total of 1,415 (5.8%) participants had at least one PVC at baseline, and 591 developed incident ischemic stroke during an average (SD) follow-up of 6.0 (2.0) years. In a Cox Proportional hazards model adjusted for age, sex, race, geographic region, education, prior heart disease, systolic blood pressure, blood pressure lowering medications, current smoking, diabetes, left ventricular hypertrophy by ECG, aspirin use and warfarin use, presence of PVCs was associated with 38% increased risk of ischemic stroke (HR (95% CI): 1.38 (1.05, 1.81)). Conclusions PVCs are common on routine screening ECGs, and are associated with an increased risk of ischemic stroke. PMID:25873602
Quantitative assessment of 12-lead ECG synthesis using CAVIAR.
Scherer, J A; Rubel, P; Fayn, J; Willems, J L
1992-01-01
The objective of this study is to assess the performance of patient-specific segment-specific (PSSS) synthesis in QRST complexes using CAVIAR, a new method of the serial comparison for electrocardiograms and vectorcardiograms. A collection of 250 multi-lead recordings from the Common Standards for Quantitative Electrocardiography (CSE) diagnostic pilot study is employed. QRS and ST-T segments are independently synthesized using the PSSS algorithm so that the mean-squared error between the original and estimated waveforms is minimized. CAVIAR compares the recorded and synthesized QRS and ST-T segments and calculates the mean-quadratic deviation as a measure of error. The results of this study indicate that estimated QRS complexes are good representatives of their recorded counterparts, and the integrity of the spatial information is maintained by the PSSS synthesis process. Analysis of the ST-T segments suggests that the deviations between recorded and synthesized waveforms are considerably greater than those associated with the QRS complexes. The poorer performance of the ST-T segments is attributed to magnitude normalization of the spatial loops, low-voltage passages, and noise interference. Using the mean-quadratic deviation and CAVIAR as methods of performance assessment, this study indicates that the PSSS-synthesis algorithm accurately maintains the signal information within the 12-lead electrocardiogram.
Takeuchi, Takahiro; Tomita, Takeshi; Kasai, Hiroki; Kashiwagi, Daisuke; Yoshie, Koji; Yaguchi, Tomonori; Oguchi, Yasutaka; Kozuka, Ayako; Gautam, Milan; Motoki, Hirohiko; Okada, Ayako; Shiba, Yuji; Aizawa, Kazunori; Izawa, Atsushi; Miyashita, Yusuke; Koyama, Jun; Hongo, Minoru; Ikeda, Uichi
2014-01-01
A 15-year-old asymptomatic male patient presented with an electrocardiographic abnormality and left ventricular (LV) dysfunction (left ventricle ejection fraction of 40%) in a physical examination performed 2 years previously. LV dysfunction did not improve despite optimal medical therapy for dilated cardiomyopathy. Twelve-lead electrocardiography revealed a normal PR interval (138 ms) with a small delta-like wave in V2, but not a typical diagnostic wave that could be diagnosed as Wolff–Parkinson–White (WPW) syndrome by an electrocardiogram auto-analysis. Transthoracic echocardiography showed a remarkable asynchronous septal motion. An electrophysiological study was performed to exclude WPW syndrome. An accessory pathway (AP) was revealed on the lateral wall of the right ventricle, and radiofrequency catheter ablation was successfully performed to disconnect the AP. Thereafter, the dyssynchrony disappeared, and LV function improved. The intrinsic atrioventricular nodal conduction was very slow (A-H, 237 ms). The results of electrocardiogram auto-analysis could not be used to confirm the diagnosis of WPW syndrome because of the atypical delta wave. Conduction via the right lateral AP caused electrical dyssynchrony in the LV. This case suggests that atypical delta waves should be evaluated without depending on electrocardiographic auto-analyses in patients with LV dysfunction accompanied by dyssynchrony. PMID:26336525
Rhythmic chaos: irregularities of computer ECG diagnosis.
Wang, Yi-Ting Laureen; Seow, Swee-Chong; Singh, Devinder; Poh, Kian-Keong; Chai, Ping
2017-09-01
Diagnostic errors can occur when physicians rely solely on computer electrocardiogram interpretation. Cardiologists often receive referrals for computer misdiagnoses of atrial fibrillation. Patients may have been inappropriately anticoagulated for pseudo atrial fibrillation. Anticoagulation carries significant risks, and such errors may carry a high cost. Have we become overreliant on machines and technology? In this article, we illustrate three such cases and briefly discuss how we can reduce these errors. Copyright: © Singapore Medical Association.
Mantziari, Lilian; Rigby, Michael; Till, Janice; Ernst, Sabine
2013-03-01
A 6-year-old girl with evidence of a parahisian accessory pathway on a baseline electrocardiogram underwent successful catheter ablation using magnetic navigation. Magnetic remote controlled ablation eliminated the parahisian pathway with the first radiofrequency application. A second anterolaterally located concealed pathway was successfully ablated in the same session, resulting in exclusively atrioventricular nodal conduction bidirectionally (total fluoroscopy, 4 min; 25 μGy).
Wide QRS tachycardia: what is the rhythm?
Rosman, Jonathan; Tawil, Joseph; Hanon, Sam; Schweitzer, Paul
2006-10-01
We report a case of an elderly man who presented to the emergency room complaining of palpitations. Electrocardiogram revealed wide QRS tachycardia with a narrow beat within the tachycardia. Most commonly, a narrow complex beat during a wide complex tachycardia suggests a capture or fusion beat in the setting of ventricular tachycardia. However, there are situations where supraventricular tachycardia can also manifest this way. In our patient a pacemaker interrogation clarified the diagnosis.
Hypertonic Saline Dextran (HSD) in a Complex Military Injury - A Preclinical Study
2010-04-01
applicable to civilian settings e.g. after terrorist bombings where there is often disruption to infrastructure and security issues relating to secondary... systemic inflammatory response that develops after trauma and which is thought to be part of the aetiology underlying later complications [19- 22...consisted of end-tidal CO2, pulse oximetry via a tail probe and skin surface electrocardiogram electrodes (Propac 106EL, Protocol Systems Inc., Oregon
Sutha, P; Jayanthi, V E
2017-12-08
Birth defect-related demise is mainly due to congenital heart defects. In the earlier stage of pregnancy, fetus problem can be identified by finding information about the fetus to avoid stillbirths. The gold standard used to monitor the health status of the fetus is by Cardiotachography(CTG), cannot be used for long durations and continuous monitoring. There is a need for continuous and long duration monitoring of fetal ECG signals to study the progressive health status of the fetus using portable devices. The non-invasive method of electrocardiogram recording is one of the best method used to diagnose fetal cardiac problem rather than the invasive methods.The monitoring of the fECG requires development of a miniaturized hardware and a efficient signal processing algorithms to extract the fECG embedded in the mother ECG. The paper discusses a prototype hardware developed to monitor and record the raw mother ECG signal containing the fECG and a signal processing algorithm to extract the fetal Electro Cardiogram signal. We have proposed two methods of signal processing, first is based on the Least Mean Square (LMS) Adaptive Noise Cancellation technique and the other method is based on the Wavelet Transformation technique. A prototype hardware was designed and developed to acquire the raw ECG signal containing the mother and fetal ECG and the signal processing techniques were used to eliminate the noises and extract the fetal ECG and the fetal Heart Rate Variability was studied. Both the methods were evaluated with the signal acquired from a fetal ECG simulator, from the Physionet database and that acquired from the subject. Both the methods are evaluated by finding heart rate and its variability, amplitude spectrum and mean value of extracted fetal ECG. Also the accuracy, sensitivity and positive predictive value are also determined for fetal QRS detection technique. In this paper adaptive filtering technique uses Sign-sign LMS algorithm and wavelet techniques with Daubechies wavelet, employed along with de noising techniques for the extraction of fetal Electrocardiogram.Both the methods are having good sensitivity and accuracy. In adaptive method the sensitivity is 96.83, accuracy 89.87, wavelet sensitivity is 95.97 and accuracy is 88.5. Additionally, time domain parameters from the plot of heart rate variability of mother and fetus are analyzed.
Gu, X J; Shan, S J; Liu, Z Z; Jin, G Z; Hu, Z Y; Zhu, L L; Zhang, J
2017-04-24
Objective: To explore the relationship between fragmented QRS complex(fQRS) and coronary collateral circulation(CCC) in patients with chronic total occlusion(CTO)lesion without prior myocardial infarction. Methods: This retrospective study analyzed 238 consecutive patients with CTO lesion in one of the major coronary arteries from May 2014 to October 2015 in our department. Patients were divided into poor CCC group (grade 0 and 1, 58 cases) and good CCC group(grade 2 and 3, 180 cases) based on Rentrop's classification of CCC. The fQRS was defined as the presence of an additional R wave or notching of R or S wave or the presence of fragmentation in two contiguous electrocardiogram leads corresponding to a major coronary artery territory. Multivariate logistic regression was used to analyze the relationship between CCC and fQRS on electrocardiogram. Results: Compared with good CCC group, patients in poor CCC group had older age((65.2±8.9)years old vs. (60.3±10.1) years old, P =0.03), higher plasma glucose ((7.22±3.00) mmol/L vs.(6.31±1.83)mmol/L, P =0.04), and lower left ventricular ejection fraction ((45.2±11.4)% vs. (51.2±13.5)%, P =0.02). None of patients had Rentrop grade 0, the presence of fQRS on ECG in patients with Rentrop grade 1, grade 2, and grade 3 CCC was 69.0% (40/58), 48.6% (35/72) , and 19.4% (21/108), respectively ( P <0.01). The presence of fQRS were higher in poor CCC group than in good CCC group (69.0%(40/58)vs. 31.1%(56/180), P <0.01), and number of leads with fQRS were higher in poor CCC group than in good CCC group (3(0, 4)vs.0(0, 3), P <0.01). Multivariate logistic regression analysis demonstrated that poor CCC growth in patients with CTO lesion without prior myocardial infarction was independently related to the presence of fQRS ( OR =3.659, 95% CI 1.619-8.217, P <0.01). Conclusion: Poor CCC in patients with CTO lesion without prior myocardial infarction is independently related to the presence of fQRS on electrocardiogram.
Electrocardiographic recognition of right ventricular hypertrophy.
Nikus, Kjell; Pérez-Riera, Andrés Ricardo; Konttila, Kaari; Barbosa-Barros, Raimundo
The electrocardiogram (ECG) is a relatively insensitive tool for the detection of right ventricular hypertrophy (RVH), but some criteria have high specificity. The recommended ECG screening criteria for RVH are not sufficiently sensitive or specific for screening for mild RVH in adults without clinical cardiovascular disease. The greatest accuracy of the ECG is in congenital heart disease, with intermediate accuracy in acquired heart disease and primary pulmonary hypertension in adults. Copyright © 2017 Elsevier Inc. All rights reserved.
2010-04-01
the lower and higher asymptotic 95 % confidence intervals were 0.812 and 0.924, respectively. Based on these results, we consider automated ...commercial success of the cardioverter- defibrillator industry clearly demonstrates that the obstacles at hand can be successfully overcome. 4.1...Does HRC Work in Real-Life Noisy Data? One of the methods reportedly designed to deal with nonstationary RRI data sets is the point correlation
2014-08-01
with the Department of Emergency Medicine, Massachusetts General Hospital, Boston, MA 02114 USA (corresponding author; phone: 617 -726-2241; e-mail...programming interface ( API ). Algorithms are used to determine the reliability of waveform (e.g., electrocardiogram) and vital-sign data (e.g., heart rate...and comparing of real-time decision- support algorithms in mobile environments," Conf Proc IEEE Eng Med Biol Soc, vol. 2009 , pp. 3417-20, 2009 . [3
2011-09-01
Electromagnetic interference (EMI) may cause some Philips Healthcare IntelliVue MMS, MP2, MP5, and X2 patient monitoring products to incorrectly display a flat electrocardiogram (ECG) waveform and generate a false asystole alarm. This occurs while the devices' pace pulse rejection feature is enabled. Facilities that suspect such behavior in their inventories should contact Philips to discuss whether installation of firmware version D.02.05 will help address the problem.
2005-03-01
electrocardiogram (ECG) by suturing one of them with 5-0 polyvinyl material to the subcutaneous tissue over the right scapula and the other one at the...bands (Pereira de Souza et al.,2001). Concentrations ofACh, Ch, their deuterated variants, and ACh turnover in brain tissue . Animals were anesthetized...mesencephalon, neocortex, piriform cortex, and striatum. These tissue fragments were homogenized in ice cold 15% IN formic acid, 85% acetone for analysis
E-healthcare at an experimental welfare techno house in Japan.
Tamura, Toshiyo; Kawarada, Atsushi; Nambu, Masayuki; Tsukada, Akira; Sasaki, Kazuo; Yamakoshi, Ken-Ichi
2007-01-01
An automated monitoring system for home health care has been designed for an experimental house in Japan called the Welfare Techno House (WTH). Automated electrocardiogram (ECG) measurements can be taken while in bed, in the bathtub, and on the toilet, without the subject's awareness, and without using body surface electrodes. In order to evaluate this automated health monitoring system, overnight measurements were performed to monitor health status during the daily lives of both young and elderly subjects.
Electrocardiogram reference intervals for clinically normal wild-born chimpanzees (Pan troglodytes).
Atencia, Rebeca; Revuelta, Luis; Somauroo, John D; Shave, Robert E
2015-08-01
To generate reference intervals for ECG variables in clinically normal chimpanzees (Pan troglodytes). 100 clinically normal (51 young [< 10 years old] and 49 adult [≥ 10 years old]) wild-born chimpanzees. Electrocardiograms collected between 2009 and 2013 at the Tchimpounga Chimpanzee Rehabilitation Centre were assessed to determine heart rate, PR interval, QRS duration, QT interval, QRS axis, P axis, and T axis. Electrocardiographic characteristics for left ventricular hypertrophy (LVH) and morphology of the ST segment, T wave, and QRS complex were identified. Reference intervals for young and old animals were calculated as mean ± 1.96•SD for normally distributed data and as 5th to 95th percentiles for data not normally distributed. Differences between age groups were assessed by use of unpaired Student t tests. RESULTS Reference intervals were generated for young and adult wild-born chimpanzees. Most animals had sinus rhythm with small or normal P wave morphology; 24 of 51 (47%) young chimpanzees and 30 of 49 (61%) adult chimpanzees had evidence of LVH as determined on the basis of criteria for humans. Cardiac disease has been implicated as the major cause of death in captive chimpanzees. Species-specific ECG reference intervals for chimpanzees may aid in the diagnosis and treatment of animals with, or at risk of developing, heart disease. Chimpanzees with ECG characteristics outside of these intervals should be considered for follow-up assessment and regular cardiac monitoring.
Pinto-Filho, Marcelo M; Brant, Luisa C C; Foppa, Murilo; Garcia-Silva, Kaiser B; Mendes de Oliveira, Rackel Aguiar; de Jesus Mendes da Fonseca, Maria; Alvim, Sheila; Lotufo, Paulo A; Mill, José G; Barreto, Sandhi M; Macfarlane, Peter W; Ribeiro, Antonio L P
2017-06-15
The electrocardiogram is a simple and useful clinical tool; nevertheless, few studies have evaluated the prevalence of electrocardiographic abnormalities in the Latin American population. This study aims to evaluate the major electrocardiographic abnormalities according to the Minnesota coding system in Brazilian adults, stratified by gender, age, race, and cardiovascular risk factors. Data from 14,424 adults (45.8% men, age 35 to 74 years) were obtained at baseline of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil), according to standardized protocol. The electrocardiogram were obtained with the Burdick Atria 6100 machine, stored on Pyramis System, automatically coded according to the Minnesota coding system by the Glasgow University software and then manually revised. Major abnormalities were more prevalent in men than women (11.3% and 7.9%, p <0.001). These differences were consistent through the different age groups, race, and number of cardiovascular risk factors. Electrocardiographic major abnormalities were more prevalent in black participants for both men (black: 15.1%, mixed: 10.4%, white: 11.1%, p = 0.001) and women (black: 10%, mixed: 7.6%, white: 7.2%, p = 0.004). In conclusion, in this large sample of Brazilian adults, the prevalence of major electrocardiographic abnormalities was higher among men, the elderly, black, and among people with more cardiovascular risk factors. Copyright © 2017 Elsevier Inc. All rights reserved.
Howarth, F C; Jacobson, M; Naseer, O; Adeghate, E
2005-03-01
A variety of contractility defects have been reported in the streptozotocin (STZ)-induced diabetic rat heart including alterations to the amplitude and time course of cardiac muscle contraction. Transmitter devices were surgically implanted in the peritoneal cavity of young adult male Wistar rats. Electrodes from the transmitter were arranged in Einthoven bipolar lead II configuration. Electrocardiogram (ECG), physical activity and body temperature data were continuously recorded with a telemetry system before and following the administration of STZ (60 mg kg-1). Heart rate (HR), physical activity and body temperature declined rapidly 3-5 days after administration of STZ. The effects became more conspicuous with time and reached a new steady state approximately 10 days after STZ treatment when HR was 255+/-8 beats min-1 in diabetic rats compared to 348+/-17 beats min-1 in age-matched controls. Heart rate variability (HRV) was also significantly reduced after STZ treatment (18+/-3 beats min-1) compared to controls (36+/-3 beats min-1). Reduced physical activity and/or body temperature may partly underlie the reduction in HR and HRV. Reductions in power spectral density at higher frequencies (2.5-3.5 Hz) suggest that parasympathetic drive to the heart may be altered during the early stages of STZ-induced diabetes. Short-term diabetes-induced changes in vital signs can be effectively tracked by continuous recording using a telemetry system.
Fabregat-Andres, Oscar; Munoz-Macho, Adolfo; Adell-Beltran, Guillermo; Ibanez-Catala, Xavier; Macia, Agustin; Facila, Lorenzo
2014-08-01
Prevention of cardiac events during competitive sports is fundamental. New technologies with remote monitoring systems integrated into clothing could facilitate the screening of heart disease. Our aim was to evaluate the feasibility of Nuubo system during a field stress test performed by soccer players, comparing results with treadmill ergospirometry as test reference. Nineteen male professional soccer players (19.2 ± 1.6 years) were studied. Wireless electrocardiographic monitoring during a Yo-Yo intermittent recovery test level 1 in soccer field and subsequent analysis of arrhythmias were firstly performed. Subsequently, in a period no longer than 4 weeks, each player underwent cardiopulmonary exercise testing in hospital. During Yo-Yo test, electrocardiogram (ECG) signal was interpretable in 16 players (84.2%). In the other three players, ECG artifacts did not allow a proper analysis. Estimation of maximum oxygen consumption was comparable between two exercise tests (VO 2 max 53.3 ± 2.4 vs. 53.7 ± 3.0 mL/kg/min for Yo-Yo test and ergometry respectively; intra-class correlation coefficient 0.84 (0.63 - 0.93), P < 0.001). No arrhythmias were detected in any player during both tests. The use of Nuubo's technology allows an accurate single-lead electrocardiographic recording and estimation of reliable performance variables during exercise testing in field, and provides a new perspective to cardiac remote monitoring in collective sports.
Novel insights into the development of chagasic cardiomyopathy: role of PI3Kinase/NO axis.
Roman-Campos, Danilo; Sales-Junior, Policarpo; Duarte, Hugo L; Gomes, Enéas R; Lara, Aline; Campos, Paula; Rocha, Nazareth N; Resende, Rodrigo R; Ferreira, Anderson; Guatimosim, Sílvia; Gazzinelli, Ricardo T; Ropert, Catherine; Cruz, Jader S
2013-09-10
Chagas' disease is one of the leading causes of heart failure in Latin American countries. Despite its great social impact, there is no direct evidence in the literature explaining the development of heart failure in Chagas' disease. Therefore, the main objective of the study was to investigate the development of the Chagas' disease towards its chronic phase and correlate with modifications in the cellular electrophysiological characteristics of the infected heart. Using a murine model of Chagas' disease, we confirmed and extended previous findings of altered electrocardiogram and echocardiogram in this cardiomyopathy. The observed changes in the electrocardiogram were correlated with the prolonged action potential and reduced transient outward potassium current density. Reduced heart function was associated with remodeling of intracellular calcium handling, altered extracellular matrix content, and to a set of proteins involved in the control of cellular contractility in ventricular myocytes. Furthermore, disruption of calcium homeostasis was partially due to activation of the PI3Kinase/nitric oxide signaling pathway. Finally, we propose a causal link between the inflammatory mediators and heart remodeling during chagasic cardiomyopathy. Altogether our results demonstrate that heart failure in Chagas' disease may occur due to electrical and mechanical remodeling of cardiac myocytes, and suggest that AKT/PI3K/NO axis could be an important pharmacological target to improve the disease outcome. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Paixão, Gabriela Miana de Mattos; Veronesi, Horácio Eduardo; da Silva, Halsted Alarcão Gomes Pereira; de Alencar Neto, José Nunes; Maldi, Carolina de Paulo; Aguiar Filho, Luciano de Figueiredo; Pinto, Ibrahim Masciarelli Francisco; de França, Francisco Faustino de Albuquerque Carneiro; Correia, Edileide de Barros
2018-01-01
Background Electrocardiogram is the initial test in the investigation of heart disease. Electrocardiographic changes in hypertrophic cardiomyopathy have no set pattern, and correlates poorly with echocardiographic findings. Cardiac magnetic resonance imaging has been gaining momentum for better assessment of hypertrophy, as well as the detection of myocardial fibrosis. Objectives To correlate the electrocardiographic changes with the location of hypertrophy in hypertrophic cardiomyopathy by cardiac magnetic resonance. Methods This descriptive cross-sectional study evaluated 68 patients with confirmed diagnosis of hypertrophic cardiomyopathy by cardiac magnetic resonance. The patients’ electrocardiogram was compared with the location of the greatest myocardial hypertrophy by cardiac magnetic resonance. Statistical significance level of 5% and 95% confidence interval were adopted. Results Of 68 patients, 69% had septal hypertrophy, 21% concentric and 10% apical hypertrophies. Concentric hypertrophy showed the greatest myocardial fibrosis mass (p < 0.001) and the greatest R wave size in D1 (p = 0.0280). The amplitudes of R waves in V5 and V6 (p = 0.0391, p = 0.0148) were higher in apical hypertrophy, with statistical significance. Apical hypertrophy was also associated with higher T wave negativity in D1, V5 and V6 (p < 0.001). Strain pattern was found in 100% of the patients with apical hypertrophy (p < 0.001). Conclusion The location of myocardial hypertrophy by cardiac magnetic resonance can be correlated with electrocardiographic changes, especially for apical hypertrophy. PMID:29538524
Vuissoz, Pierre-André; Odille, Freddy; Fernandez, Brice; Lohezic, Maelene; Benhadid, Adnane; Mandry, Damien; Felblinger, Jacques
2012-02-01
To assess cardiac function by means of a novel free-breathing cardiac magnetic resonance imaging (MRI) strategy. A stack of ungated 2D steady-state free precession (SSFP) slices was acquired during free breathing and reconstructed as cardiac cine imaging based on the generalized reconstruction by inversion of coupled systems (GRICS). A motion-compensated sliding window approach allows reconstructing cine movies with most motion artifacts cancelled. The proposed reconstruction uses prior knowledge from respiratory belts and electrocardiogram recordings and features a piecewise linear model that relates the electrocardiogram signal to cardiac displacements. The free-breathing protocol was validated in six subjects against a standard breath-held protocol. Image sharpness, as assessed by the image gradient entropy, was comparable to that of breath-held images and significantly better than in uncorrected images. Volumetric parameters of cardiac function in the left ventricle (LV) and right ventricle (RV) were similar, including end-systolic volumes, end-diastolic volumes and mass, stroke volumes, and ejection fractions (with differences of 3% ± 2.4 in the LV and 2.9% ± 4.4 in the RV). The duration of the free-breathing protocol was nearly the same as the breath-held protocol. Free-breathing cine-GRICS enables accurate assessment of volumetric parameters of cardiac function with efficient correction of motion. Copyright © 2011 Wiley Periodicals, Inc.
Yang, Kai; Jiang, Xuejun; Cheng, Shuqun; Chen, Chengzhi; Cao, Xianqing; Tu, Baijie
2017-01-24
To evaluate the effects of occupational exposures to coke oven emissions (COEs) and benzo[a]pyrene (B[a]P) on the prevalence of hypertension and abnormal electrocardiogram (ECG) in coke oven workers. We included 880 coke oven workers and 710 oxygen employees in the exposed and control groups, respectively. Blood pressure (BP), ECG, blood lipid levels, and glucose levels of all subjects were measured. COE and B[a]P concentrations at the bottom, side, and top of the oven and control plants were estimated by weighing and high-performance liquid chromatography. The COE concentration at the top and side was higher than that at the bottom (P < 0.05). The levels of B[a]P at the top and side significantly exceeded the limit value. Abnormal BP, ECG, the detection ratio of hypertension and left ventricular high voltage were significantly greater in the exposed group than in the control group (P < 0.05). The logistic regression analysis results revealed that age and B[a]P exposure were risk factors for hypertension in coke oven workers (P < 0.05) and both were risk factors for abnormal ECG (P < 0.05). Moreover, B[a]P exposure, age, and gender were risk factors for impaired fasting glucose in coke oven workers (P < 0.05). B[a]P and COE exposures are risk factors for hypertension and abnormal ECG in coke oven workers.
Real-Time Monitoring and Analysis of Zebrafish Electrocardiogram with Anomaly Detection.
Lenning, Michael; Fortunato, Joseph; Le, Tai; Clark, Isaac; Sherpa, Ang; Yi, Soyeon; Hofsteen, Peter; Thamilarasu, Geethapriya; Yang, Jingchun; Xu, Xiaolei; Han, Huy-Dung; Hsiai, Tzung K; Cao, Hung
2017-12-28
Heart disease is the leading cause of mortality in the U.S. with approximately 610,000 people dying every year. Effective therapies for many cardiac diseases are lacking, largely due to an incomplete understanding of their genetic basis and underlying molecular mechanisms. Zebrafish ( Danio rerio ) are an excellent model system for studying heart disease as they enable a forward genetic approach to tackle this unmet medical need. In recent years, our team has been employing electrocardiogram (ECG) as an efficient tool to study the zebrafish heart along with conventional approaches, such as immunohistochemistry, DNA and protein analyses. We have overcome various challenges in the small size and aquatic environment of zebrafish in order to obtain ECG signals with favorable signal-to-noise ratio (SNR), and high spatial and temporal resolution. In this paper, we highlight our recent efforts in zebrafish ECG acquisition with a cost-effective simplified microelectrode array (MEA) membrane providing multi-channel recording, a novel multi-chamber apparatus for simultaneous screening, and a LabVIEW program to facilitate recording and processing. We also demonstrate the use of machine learning-based programs to recognize specific ECG patterns, yielding promising results with our current limited amount of zebrafish data. Our solutions hold promise to carry out numerous studies of heart diseases, drug screening, stem cell-based therapy validation, and regenerative medicine.
Effects of neurofeedback therapy in healthy young subjects.
Altan, Sümeyra; Berberoglu, Bercim; Canan, Sinan; Dane, Şenol
2016-12-01
Neurofeedback refers to a form of operant conditioning of electrical brain activity, in which desirable brain activity is rewarded and undesirable brain activity is inhibited. The research team aimed to examine the efficacy of neurofeedback therapy on electroencephalogram (EEG) for heart rate, electrocardiogram (ECG) and galvanic skin resistance (GSR) parameters in a healthy young male population. Forty healthy young male subjects aged between 18 to 30 years participated in this study. Neurofeedback application of one session was made with bipolar electrodes placed on T3 and T4 (temporal 3 and 4) regions and with reference electrode placed on PF1 (prefrontal 1). Electroencephalogram (EEG), electrocardiogram (ECG) and galvanic skin resistance (GSR) were assessed during Othmer neurofeedback application of one session to regulate slow wave activity for forty minutes thorough the session. Data assessed before neurofeedback application for 5 minutes and during neurofeedback application of 30 minutes and after neurofeedback application for 5 minutes throughout the session of 40 minutes. Means for each 5 minutes, that is to say, a total 8 data points for each subjects over 40 minutes, were assessed. Galvanic skin resistance increased and heart rate decreased after neurofeedback therapy. Beta activity in EEG increased and alfa activity decreased after neurofeedback therapy. These results suggest that neurofeedback can be used to restore sympathovagal imbalances. Also, it may be accepted as a preventive therapy for psychological and neurological problems.
Norton, Loretta; Gibson, Raechelle M; Gofton, Teneille; Benson, Carolyn; Dhanani, Sonny; Shemie, Sam D; Hornby, Laura; Ward, Roxanne; Young, G Bryan
2017-03-01
The timing of the circulatory determination of death for organ donation presents a medical and ethical challenge. Concerns have been raised about the timing of electrocerebral inactivity in relation to the cessation of circulatory function in organ donation after cardio-circulatory death. Nonprocessed electroencephalographic (EEG) measures have not been characterized and may provide insight into neurological function during this process. We assessed electrocortical data in relation to cardiac function after withdrawal of life-sustaining therapy and in the postmortem period after cardiac arrest for four patients in a Canadian intensive care unit. Subhairline EEG and cardio-circulatory monitoring including electrocardiogram, arterial blood pressure (ABP), and oxygen saturation were captured. Electrocerebral inactivity preceded the cessation of the cardiac rhythm and ABP in three patients. In one patient, single delta wave bursts persisted following the cessation of both the cardiac rhythm and ABP. There was a significant difference in EEG amplitude between the 30-minute period before and the 5-minute period following ABP cessation for the group, but we did not observe any well-defined EEG states following the early cardiac arrest period. In a case series of four patients, EEG inactivity preceded electrocardiogram and ABP inactivity during the dying process in three patients. Further study of the electroencephalogram during the withdrawal of life sustaining therapies will add clarity to medical, ethical, and legal concerns for donation after circulatory determined death.
Real-Time Monitoring and Analysis of Zebrafish Electrocardiogram with Anomaly Detection
Lenning, Michael; Fortunato, Joseph; Le, Tai; Clark, Isaac; Sherpa, Ang; Yi, Soyeon; Hofsteen, Peter; Thamilarasu, Geethapriya; Yang, Jingchun; Xu, Xiaolei; Hsiai, Tzung K.; Cao, Hung
2017-01-01
Heart disease is the leading cause of mortality in the U.S. with approximately 610,000 people dying every year. Effective therapies for many cardiac diseases are lacking, largely due to an incomplete understanding of their genetic basis and underlying molecular mechanisms. Zebrafish (Danio rerio) are an excellent model system for studying heart disease as they enable a forward genetic approach to tackle this unmet medical need. In recent years, our team has been employing electrocardiogram (ECG) as an efficient tool to study the zebrafish heart along with conventional approaches, such as immunohistochemistry, DNA and protein analyses. We have overcome various challenges in the small size and aquatic environment of zebrafish in order to obtain ECG signals with favorable signal-to-noise ratio (SNR), and high spatial and temporal resolution. In this paper, we highlight our recent efforts in zebrafish ECG acquisition with a cost-effective simplified microelectrode array (MEA) membrane providing multi-channel recording, a novel multi-chamber apparatus for simultaneous screening, and a LabVIEW program to facilitate recording and processing. We also demonstrate the use of machine learning-based programs to recognize specific ECG patterns, yielding promising results with our current limited amount of zebrafish data. Our solutions hold promise to carry out numerous studies of heart diseases, drug screening, stem cell-based therapy validation, and regenerative medicine. PMID:29283402
Portable electrocardiogram device using Android smartphone.
Brucal, S G E; Clamor, G K D; Pasiliao, L A O; Soriano, J P F; Varilla, L P M
2016-08-01
Portable electrocardiogram (ECG) capturing device can be interfaced to a smart phone installed with an android-based application (app). This app processes and analyses the data sent by the device to provide an interpretation of the patient/user's heart current condition (e.g.: beats per minute, heart signal waveform, R-R interval). The ECG recorded by the app is stored in the smart phone's Secure Digital (SD) card and cloud storage which can be accessed remotely by a physician to aid in providing medical diagnosis. The project aims to help patients living at a far distance from hospitals and experience difficulty in consulting their physician for regular check-ups, and assist doctors in regularly monitoring their patient's heart condition. The hardware data acquisition device and software application were subjected to trials in a clinic with volunteer-patients to measure the ECG and heart rate, data saving speed on the SD card, success rate of the saved data and uploaded file. Different ECG tests using the project prototype were done for 12 patients/users and yielded a reading difference of 7.61% in an R-R interval reading and 5.35% in heart rate reading as compared with the cardiologist's conventional 12-electrode ECG machine. Using the developed ECG device, it took less than 5 seconds to save ECG reading using SD card and approximately 2 minutes to upload via cloud.
NASA Technical Reports Server (NTRS)
Estes, N. A. 3rd; Michaud, G.; Zipes, D. P.; El-Sherif, N.; Venditti, F. J.; Rosenbaum, D. S.; Albrecht, P.; Wang, P. J.; Cohen, R. J.
1997-01-01
This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.
Margonato, A; Ballarotto, C; Bonetti, F; Cappelletti, A; Sciammarella, M; Cianflone, D; Chierchia, S L
1992-04-01
The assessment of residual myocardial viability in infarcted areas is relevant for subsequent management and prognosis but requires expensive technology. To evaluate the possibility that simple, easily obtainable clinical markers may detect the presence of within-infarct viable tissue, the significance of exercise-induced ST elevation occurring in leads exploring the area of a recent Q wave myocardial infarction was assessed. Twenty-five patients with recent (less than 6 months) myocardial infarction were studied. All had angiographically documented coronary artery disease, diagnostic Q waves (n = 24) or negative T waves (n = 25) on the rest 12-lead electrocardiogram and exhibited during exercise greater than or equal to 1.5 mm ST segment elevation (n = 17) or isolated T wave pseudonormalization (n = 8) in the infarct-related leads. ST-T wave changes were reproduced in all patients during thallium-201 exercise myocardial scintigraphy. A fixed perfusion defect was observed in 24 of the 25 patients. A reversible defect was seen in 16 (94%) of 17 patients who exhibited transient ST elevation during exercise but in only 4 (50%) of the 8 patients who had only T wave pseudonormalization. In conclusion, in patients with recent myocardial infarction, analysis of simple ST segment variables obtained during exercise testing may allow a first-line discrimination of those who may potentially benefit from a revascularization procedure.
Takahara, Akira; Sugiyama, Atsushi; Ishida, Yuko; Satoh, Yoshioki; Wang, Kai; Nakamura, Yuji; Hashimoto, Keitaro
2006-03-01
Although a second-generation histamine H(1) blocker terfenadine induced torsades de pointes (TdP) arrhythmias in patients via the blockade of a rapid component of delayed rectifier K(+) current (I(Kr)), such action of terfenadine has not been detected in previous animal models. We analysed the potential of the canine persistent atrioventricular block heart, a new in vivo proarrhythmia model, to detect a torsadogenic effect of terfenadine of an oral dose of 3 or 30 mg kg(-1). The doses can provide therapeutic to supra-therapeutic plasma concentrations as an anti-histamine. In 2 weeks of bradycardiac heart model, there were no significant changes in any of the electrocardiogram parameters after the administration of both doses of terfenadine. In 4-6 weeks of bradycardiac heart model, the low dose of terfenadine hardly affected any of the electrocardiogram parameters except that it induced TdP in one out of six animals. The high dose significantly decreased the atrial rate and ventricular rate, prolonged the QT interval, and induced TdP in five out of six animals. Moreover, temporal variability of repolarization increased after the high-dose administration. These results suggest that long-term bradycardia caused by atrioventricular block can remodel the canine heart to detect terfenadine-induced TdP.
Preejection period can be calculated using R peak instead of Q.
Seery, Mark D; Kondrak, Cheryl L; Streamer, Lindsey; Saltsman, Thomas; Lamarche, Veronica M
2016-08-01
Preejection period (PEP) is a common measure of sympathetic nervous system activation in psychophysiological research, which makes it important to measure reliably for as many participants as possible. PEP is typically calculated as the interval between the onset or peak of the electrocardiogram Q wave and the impedance cardiography B point, but the Q wave can lack clear definition and even its peak is not visible for all participants. We thus investigated the feasibility of using the electrocardiogram R wave peak (Rpeak ) instead of Q because it can be consistently identified with ease and precision. Across four samples (total N = 408), young adult participants completed a variety of minimally metabolically demanding laboratory tasks after a resting baseline. Results consistently supported a close relationship between absolute levels of the Rpeak -B interval and PEP (accounting for approximately 90% of the variance at baseline and 89% during task performance, on average), but for reactivity values, Rpeak -B was practically indistinguishable from PEP (accounting for over 98% of the variance, on average). Given that using Rpeak rather than the onset or peak of Q saves time, eliminates potential subjectivity, and can be applied to more participants (i.e., those without a visible Q wave), findings suggest that Rpeak -B likely provides an adequate estimate of PEP when absolute levels are of interest and clearly does so for within-person changes. © 2016 Society for Psychophysiological Research.
Shara, Mohd; Stohs, Sidney J; Smadi, Mahmoud M
2018-01-01
Extracts of bitter orange (BOE, Citrus aurantium L.) and its primary protoalkaloid p-synephrine are extensively consumed as dietary supplements. p-Synephrine is also present in foods and juices prepared from various Citrus species. The safety of p-synephrine has been questioned as a result of structural similarities with ephedrine. This study assessed the cardiovascular (stimulant) and hemodynamic effects of BOE (49 mg p-synephrine) daily given to 16 healthy subjects for 15 days in a placebo-controlled, cross-over, double-blinded study. A physical evaluation by a cardiologist, as well as heart rates, blood pressures, and electrocardiograms were determined, and blood samples were drawn at baseline, and Days 5, 10, and 15. Serum levels for caffeine and p-synephrine were measured at 1 and 2 weeks. Subjects completed a 10-item health and metabolic questionnaire at baseline and on Day 15. No significant changes occurred in heart rate, electrocardiograms, systolic blood or diastolic pressures, blood cell counts, or blood chemistries in either the control or p-synephrine treated groups at any time point. No adverse effects were reported in response to the bitter orange (p-synephrine). Caffeine consumed by the participants varied markedly. Under these experimental conditions, BOE and p-synephrine were without stimulant (cardiovascular) and adverse effects. Copyright © 2017 John Wiley & Sons, Ltd.
Lasky, Robert E; Parikh, Nehal A; Williams, Amber L; Padhye, Nikhil S; Shankaran, Seetha
2009-01-01
Little is known about the effects of hypothermia therapy and subsequent rewarming on the PQRST intervals and heart rate variability (HRV) in term newborns with hypoxic-ischemic encephalopathy (HIE). This study describes the changes in the PQRST intervals and HRV during rewarming to normal core body temperature of 2 newborns with HIE after hypothermia therapy. Within 6 h after birth, 2 newborns with HIE were cooled to a core body temperature of 33.5 degrees C for 72 h using a cooling blanket, followed by gradual rewarming (0.5 degrees C per hour) until the body temperature reached 36.5 degrees C. Custom instrumentation recorded the electrocardiogram from the leads used for clinical monitoring of vital signs. Generalized linear mixed models were calculated to estimate temperature-related changes in PQRST intervals and HRV. For every 1 degrees C increase in body temperature, the heart rate increased by 9.2 bpm (95% CI 6.8-11.6), the QTc interval decreased by 21.6 ms (95% CI 17.3-25.9), and low and high frequency HRV decreased by 0.480 dB (95% CI 0.052-0.907) and 0.938 dB (95% CI 0.460-1.416), respectively. Hypothermia-induced changes in the electrocardiogram should be monitored carefully in future studies. Copyright 2009 S. Karger AG, Basel.
A survey of paediatricians on the use of electrocardiogram for pre-participation sports screening.
Patel, Angira; Webster, Gregory; Ward, Kendra; Lantos, John
2017-07-01
Aim The aim of the present study was to determine general paediatrician knowledge, practices, and attitudes towards electrocardiogram (ECG) screening in school athletes during pre-participation screening exam (PPSE). Paediatricians affiliated with a tertiary children's hospital completed a survey about ECGs for PPSE. In total, 205/498 (41%) responded; 92% of the paediatricians did not include an ECG as part of PPSE; 56% were aware of a case in which a student athlete in their own community had died of sudden unexplained death; 4% had an athlete in their practice die. Only 16% of paediatricians perform all 12 American Heart Association recommended elements of the PPSE. If any of these screening elements are abnormal, 69% obtain an ECG, 36% an echocardiogram, and 30% restrict patients from sports activity; 73% of them refer the patient to a cardiologist. Most of the general paediatricians surveyed did not currently perform ECGs for PPSE. In addition, there was a low rate of adherence to performing the 12 screening elements recommended by the American Heart Association. They have trouble obtaining timely, accurate ECG interpretations, worry about potential unnecessary exercise restrictions, and cost-effectiveness. The practical hurdles to ECG implementation emphasise the need for a fresh look at PPSE, and not just ECG screening. Improvements in ECG performance/interpretation would be necessary for ECGs to be a useful part of PPSE.
Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang
2016-06-01
The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.
Ichihashi, Taku; Ito, Tsuyoshi; Murai, Shunsuke; Ikehara, Noriyuki; Fujita, Hiroshi; Suda, Hisao; Ohte, Nobuyuki
2016-09-01
A 58-year-old man was referred to our hospital because of chest pain. The 12-lead electrocardiogram (ECG) revealed ST-segment elevation in II, III, and a Vf with advanced heart block. Transthoracic echocardiography demonstrated aortic root dilatation at the sinus of Valsalva, moderate aortic regurgitation, and decreased wall motion in the inferior part of the left ventricle. Non-ECG-gated enhanced computed tomography (CT) did not reveal an aortic dissection. The patient underwent emergent coronary angiography, which revealed a severely narrowed ostium of the right coronary artery (RCA). Percutaneous coronary intervention (PCI) was performed under intravascular ultrasound (IVUS) guidance. IVUS images demonstrated an intimal flap extending from the aortic wall to the proximal RCA, suggesting that a periaortic hematoma in the false lumen compressed the ostium of the RCA, leading to acute myocardial infarction. To recover hemodynamic stability, the RCA ostium was stented. Subsequent ECG-gated enhanced CT clearly depicted the entry point and extension of the dissection localized within the sinus of Valsalva. The dissection likely involved the left main coronary artery and an emergent Bentall procedure was performed. Intraoperative findings confirmed an intimal tear and extension of the dissection. Thus, ECG-gated CT can clearly depict the entry site and extension of a dissection occurring in the localized area that cannot be detected by conventional CT.
Complete atrioventricular block following mediastinal irradiation: A report of six cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slama, M.S.; Le Guludec, D.; Sebag, C.
1991-07-01
Complete atrioventricular block (AVB) following radiotherapy has been reported rarely, usually after high dose mediastinal irradiation for Hodgkin's disease or lung or breast carcinoma. The authors report six new cases of episodic complete infranodal AVB, requiring permanent pacemaker implantation. The mean age was 48-years old (ranging from 25-60) at the first Adams Stokes attack, mean delay was 12 years after irradiation (10-18), and mean radiation dose was 5,200 rads (4,000-6,500). All patients had abnormal interval electrocardiograms (right bundle branch block in two, left bundle branch block in three, alternating left and right bundle branch block in one). Electrocardiograms during themore » episode of AVB or Holter recordings were consistent with infranodal block in all patients; electrophysiological study performed in five patients confirmed infranodal AVB in four, and one was normal. Pericardial disease was constant, which included pericardial constriction in four patients. Two patients died after failure of pericardiectomy to improve congestive heart failure, due to epicardial, myocardial, and endocardial involvement. Noncardiac mediastinal lesions were present in four cases. Since this delayed complication may occur in patients of such age that the relation between the AVB and the chest irradiation is questionable, they propose the following etiologic criteria; high radiation dose (over 4,000 rads); delay of 10 years or more; abnormal interval tracings; pericardial involvement; and associated cardiac or mediastinal radiation-induced lesions.« less
Fang, Qiang; Mahmoud, Seedahmed S; Yan, Jiayong; Li, Hui
2016-11-23
For this investigation, we studied the effects of extremely low frequency pulse electromagnetic fields (ELF-PEMF) on the human cardiac signal. Electrocardiograms (ECGs) of 22 healthy volunteers before and after a short duration of ELF-PEMF exposure were recorded. The experiment was conducted under single-blind conditions. The root mean square (RMS) value of the recorded data was considered as comparison criteria. We also measured and analysed four important ECG time intervals before and after ELF-PEMF exposure. Results revealed that the RMS value of the ECG recordings from 18 participants (81.8% of the total participants) increased with a mean value of 3.72%. The increase in ECG voltage levels was then verified by a second experimental protocol with a control exposure. In addition to this, we used hyperbolic T-distributions (HTD) in the analysis of ECG signals to verify the change in the RR interval. It was found that there were small shifts in the frequency-domain signal before and after EMF exposure. This shift has an influence on all frequency components of the ECG signals, as all spectrums were shifted. It is shown from this investigation that a short time exposure to ELF-PEMF can affect the properties of ECG signals. Further study is needed to consolidate this finding and discover more on the biological effects of ELF-PEMF on human physiological processes.
Peel, Sarah A; Hussain, Tarique; Cecelja, Marina; Abbas, Abeera; Greil, Gerald F; Chowienczyk, Philip; Spector, Tim; Smith, Alberto; Waltham, Matthew; Botnar, Rene M
2011-11-01
To accelerate and optimize black blood properties of the quadruple inversion recovery (QIR) technique for imaging the abdominal aortic wall. QIR inversion delays were optimized for different heart rates in simulations and phantom studies by minimizing the steady state magnetization of blood for T(1) = 100-1400 ms. To accelerate and improve black blood properties of aortic vessel wall imaging, the QIR prepulse was combined with zoom imaging and (a) "traditional" and (b) "trailing" electrocardiogram (ECG) triggering. Ten volunteers were imaged pre- and post-contrast administration using a conventional ECG-triggered double inversion recovery (DIR) and the two QIR implementations in combination with a zoom-TSE readout. The QIR implemented with "trailing" ECG-triggering resulted in consistently good blood suppression as the second inversion delay was timed during maximum systolic flow in the aorta. The blood signal-to-noise ratio and vessel wall to blood contrast-to-noise ratio, vessel wall sharpness, and image quality scores showed a statistically significant improvement compared with the traditional QIR implementation with and without ECG-triggering. We demonstrate that aortic vessel wall imaging can be accelerated with zoom imaging and that "trailing" ECG-triggering improves black blood properties of the aorta which is subject to motion and variable blood flow during the cardiac cycle. Copyright © 2011 Wiley Periodicals, Inc.
Rotondi, Francesco; Manganelli, Fiore; Candelmo, Fiore; Marino, Luciano; Di Lorenzo, Emilio; Alfano, Ferdinando; Stanco, Giovanni; Rosato, Giuseppe
2010-07-01
We report the case of a 77-year-old man, in whom accidental hypothermia was secondary to prolonged immobilization and malnutrition. The electrocardiogram showed typical Osborn waves, which disappeared with the rewarming of the patient. The diagnosis of hypothermia is easy in patients with a history of prolonged exposure to a cold environment but accidental hypothermia may also occur as a consequence of prolonged immobilization and malnutrition. ECG analysis is very important for a correct and fast diagnosis.
Fetal ECG Extraction From Maternal Body Surface Measurement Using Independent Component Analysis
2001-10-25
Ibaraki 305-0901, Japan Abstract – A method applying independent component analysis (ICA) to detect the electrocardiogram of a prenatal cattle foetus is...monitoring the health status of an unborn cattle foetus is indispensable in preventing natural abortion and premature birth [3]. One of the applicable...and Y. Honda, “ECG and Heart Rate Detection of Prenatal Cattle Foetus Using Adaptive Digital Filtering,” World Congress on Med. Phys.& Biomed. Eng., Chicago TU-CXH-75, pp. 1-4, 2000.
ECG (Electrocardiogram) Interpretation Training Program - Reference Manual
1984-05-08
4) PRESS THE "AUTOLOAD" KEY - this will automatically load and activate the program and bring the user to the starting point . 5) FOLLOW THE...will give you some familiarity with the landmarks. Try to go thru a few, picking out first the QRS, its the only pointed one!, then the P and T...This is the very top of the sternum, just between the medial ends of the clavicles or collar bones. From this point palpate down the sternum
Scleroderma Renal Crisis: A Reversible Cause of Left Ventricular Dysfunction.
Martínez-Milla, Juan; Gaebelt, Hans Paul; Sánchez-Pernaute, Olga; Kallmeyer, Andrea; Romero, José; Farré, Jerónimo
2018-05-02
We report a case of acute left ventricular dysfunction due to myocarditis, in the setting of a scleroderma renal crisis. The case is particularly intriguing for the favorable outcome of both symptoms and heart function following immunosuppressive therapy. We also highlight the changes observed over time with image techniques as well as in electrocardiograms. Copyright © 2018 Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. Publicado por Elsevier España, S.L.U. All rights reserved.
1985-12-01
a healthy coronary artery can increase flow ninefold by dilating during peak workloads. By preventing dilation , circum- ferential atherosclerosis...Ischemic Canine Myocardium, J. Electrocardiol. 15(4):335, 1982. 127. Burgess, M.J., Green, L.S., Millar, K., Wyatt, R., and Abildskov, J.A.: The...Refractory Periods of Ischemic Canine Ventricular Myocardium, J. Electrocardiol. 15(1):I, 1982. 129. Burgess, M.J., Lux, R.L., Wyatt, R.F., and Abildskov, J.A
Prediction of heart abnormality using MLP network
NASA Astrophysics Data System (ADS)
Hashim, Fakroul Ridzuan; Januar, Yulni; Mat, Muhammad Hadzren; Rizman, Zairi Ismael; Awang, Mat Kamil
2018-02-01
Heart abnormality does not choose gender, age and races when it strikes. With no warning signs or symptoms, it can result to a sudden death of the patient. Generally, heart's irregular electrical activity is defined as heart abnormality. Via implementation of Multilayer Perceptron (MLP) network, this paper tries to develop a program that allows the detection of heart abnormality activity. Utilizing several training algorithms with Purelin activation function, an amount of heartbeat signals received through the electrocardiogram (ECG) will be employed to condition the MLP network.
[Electrocardiographic interpretation in athletes : 2017 recommendations for non-cardiologists].
Meyer, Philippe; Gabus, Vincent
2017-07-12
A resting electrocardiogram (ECG) is recommended for screening of sudden cardiac death in young athletes. However, ECG interpretation in athletes requires an adequate training because normal physiological training adaptations in athletes can sometimes be hardly distinguished from abnormal findings suggestive of underlying pathology. In 2017, a consensus of international experts established new recommendations for a clear and accurate interpretation of ECGs in athletes. This article aims to guide non-cardiologists according to these new data, allowing a better triage of anomalies requiring further investigations.
Coleman during ICV Assessment in the Kibo JPM during Expedition 26
2011-01-07
ISS026-E-015923 (7 Jan. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, participates in the ambulatory monitoring part of the Integrated Cardiovascular (ICV) assessment research experiment in the Kibo laboratory of the International Space Station. Coleman is wearing electrodes, a Holter Monitor 2 (HM2) for recording Electrocardiogram (ECG), a European Space Agency (ESA) Cardio pressure / Blood Pressure unit to continuously monitor blood pressure and two Actiwatches (hip/waist and ankle) for monitoring activity levels.
Dadlani, Akash; Dukes, Jonathan W; Badhwar, Nitish
2016-03-01
This case shows the complexity of arrhythmia management in patients with implantable cardioverter-defibrillators (ICDs) who present with hyperkalemia. In order to prevent inappropriate ICD shock, consideration should be given to the suspension of ICD therapies while intensive care treatment of extreme electrolyte derangements is being pursued. Patients in these setting should be closely monitored until their electrocardiograms have normalized, after which the device can safely be reactivated. Copyright © 2016 Elsevier Inc. All rights reserved.