Sample records for electrocardiography

  1. Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System.

    PubMed

    Khumrin, Piyapong; Chumpoo, Pitupoom

    2016-03-01

    Electrocardiography is one of the most important non-invasive diagnostic tools for diagnosing coronary heart disease. The electrocardiography information system in Maharaj Nakorn Chiang Mai Hospital required a massive manual labor effort. In this article, we propose an approach toward the integration of heterogeneous electrocardiography data and the implementation of an integrated electrocardiography information system into the existing Hospital Information System. The system integrates different electrocardiography formats into a consistent electrocardiography rendering by using Java software. The interface acts as middleware to seamlessly integrate different electrocardiography formats. Instead of using a common electrocardiography protocol, we applied a central format based on Java classes for mapping different electrocardiography formats which contains a specific parser for each electrocardiography format to acquire the same information. Our observations showed that the new system improved the effectiveness of data management, work flow, and data quality; increased the availability of information; and finally improved quality of care. © The Author(s) 2014.

  2. Feline arrhythmias: an update.

    PubMed

    Côté, Etienne

    2010-07-01

    In the cat, electrocardiography is indicated for assessing the rhythm of the heartbeat and identifying and monitoring the effect of certain systemic disorders on the heart. Basic information regarding feline electrocardiography is contained in several textbooks, and the reader is referred to these sources for background reading. This article describes selected clinical advances in feline cardiac arrhythmias and electrocardiography from the past decade.

  3. Problems in Recording the Electrocardiogram.

    ERIC Educational Resources Information Center

    Webster, John G.

    The unwanted signals that arise in electrocardiography are discussed. A technical background of electrocardiography is given, along with teaching techniques that educate students of medical instrumentation to solve the problems caused by these signals. (MJH)

  4. Assessment of electrocardiographic criteria of left atrial enlargement.

    PubMed

    Batra, Mahesh Kumar; Khan, Atif; Farooq, Fawad; Masood, Tariq; Karim, Musa

    2018-05-01

    Background Left atrial enlargement is considered to be a robust, strong, and widely acceptable indicator of cardiovascular outcomes. Echocardiography is the gold standard for measurement of left atrial size, but electrocardiography can be simple, cost-effective, and noninvasive in clinical practice. This study was undertaken to assess the diagnostic accuracy of an established electrocardiographic criterion for left atrial enlargement, taking 2-dimensional echocardiography as the gold-standard technique. Methods A cross-sectional study was conducted on 146 consecutively selected patients with the complaints of dyspnea and palpitation and with a murmur detected on clinical examination, from September 10, 2016 to February 10, 2017. Electrocardiography and echocardiography were performed in all patients. Patients with a negative P wave terminal force in lead V 1  > 40 ms·mm on electrocardiography or left atrial dimension > 40 mm on echocardiography were classified as having left atrial enlargement. Sensitivity and specificity were calculated to assess the diagnostic accuracy. Results Taking 2-dimensional echocardiography as the gold-standard technique, electrocardiography correctly diagnosed 68 patients as positive for left atrial enlargement and 12 as negative. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of electrocardiography for left atrial enlargement were 54.4%, 57.1%, 88.3%, 17.4%, and 54.8%, respectively. Conclusion The electrocardiogram appears to be a reasonable indicator of left atrial enlargement. In case of nonavailability of echocardiography, electrocardiography can be used for diagnosis of left atrial enlargement.

  5. A Subthreshold Digital Library Using a Dynamic-Threshold Metal-Oxide Semiconductor (DTMOS) and Transmission Gate Logic

    DTIC Science & Technology

    2014-09-01

    electrocardiography (ECG), electromyography (EMG), and electroencephalography (EEG) applications that operate using thermoelectrically generated energy...semiconductor ECG electrocardiography EEG electroencephalography EMG electromyography FY15 fiscal year 2015 IC integrated circuit MOSFETs

  6. Myocardial perfusion imaging with thallium-201: correlation with coronary arteriography and electrocardiography

    PubMed Central

    Sternberg, Leonard; Wald, Robert W.; Feiglin, David H.I.; Morch, John E.

    1978-01-01

    Myocardial perfusion imaging with thallium-201 and electrocardiography with the subject at rest and undergoing submaximal treadmill exercise were performed in 19 men and 3 women. Selective coronary arteriography and left ventriculography showed that 7 had normal coronary arteries and 15 had coronary artery disease. The 11 persons with electrocardiographic evidence of an old myocardial infarct (q waves) had a perfusion defect at rest in the area of the infarct and a segmental abnormality of wall motion apparent on the left ventriculogram corresponding to the perfusion defect. Myocardial perfusion imaging and electrocardiography were equally sensitive in detecting coronary artery disease in exercising individuals: perfusion defects were noted in 7 of the 15 persons with coronary artery disease, and diagnostic ST-segment depression was present in 8 of the 15. Combination of the results of the two tests with exercise permitted the identification of 11 of the 15 persons and improved the sensitivity. Combination of the results of rest and exercise imaging and electrocardiography permitted the identification of 94% of the patients with coronary artery disease. Myocardial perfusion imaging with 201TI in the subject at rest is a sensitive indicator of previous myocardial infarction. Imaging after the subject has exercised is a useful adjunct to conventional exercise electrocardiography, especially in those whose exercise electrocardiogram is non-interpretable. ImagesFIG. 1FIG. 2FIG. 3FIG. 4FIG. 5 PMID:630487

  7. Vectorcardiographic diagnostic & prognostic information derived from the 12-lead electrocardiogram: Historical review and clinical perspective.

    PubMed

    Man, Sumche; Maan, Arie C; Schalij, Martin J; Swenne, Cees A

    2015-01-01

    In the course of time, electrocardiography has assumed several modalities with varying electrode numbers, electrode positions and lead systems. 12-lead electrocardiography and 3-lead vectorcardiography have become particularly popular. These modalities developed in parallel through the mid-twentieth century. In the same time interval, the physical concepts underlying electrocardiography were defined and worked out. In particular, the vector concept (heart vector, lead vector, volume conductor) appeared to be essential to understanding the manifestations of electrical heart activity, both in the 12-lead electrocardiogram (ECG) and in the 3-lead vectorcardiogram (VCG). Not universally appreciated in the clinic, the vectorcardiogram, and with it the vector concept, went out of use. A revival of vectorcardiography started in the 90's, when VCGs were mathematically synthesized from standard 12-lead ECGs. This facilitated combined electrocardiography and vectorcardiography without the need for a special recording system. This paper gives an overview of these historical developments, elaborates on the vector concept and seeks to define where VCG analysis/interpretation can add diagnostic/prognostic value to conventional 12-lead ECG analysis. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Electrocardiography as a Tool for Validating Myocardial Ischemia–Reperfusion Procedures in Mice

    PubMed Central

    Preda, Mihai B; Burlacu, Alexandrina

    2010-01-01

    This paper evaluates the modifications induced by ischemia and ischemia–reperfusion in mice after permanent or transient, respectively, ligation of the left coronary artery and establishes a correlation among the extent of ischemia, electrocardiograph features, and infarct size. The left coronary artery was ligated 1 mm distal from the tip of the left auricle. Histologic analysis revealed that 30-min ischemia (n = 9) led to infarction involving 9.7% ± 0.5% of the left ventricle, whereas 1-h ischemia (n = 9) resulted in transmural infarction of 16.1% ± 4.6% of the left ventricle. In contrast, 24-h ischemia (n = 8) and permanent ischemia (n = 8) induced similarly sized infarcts (33% ± 2% and 31.8% ± 0.7%, respectively), suggesting ineffective reperfusion after 24-h ischemia. Electrocardiography revealed that ligation of the left coronary artery led to ST height elevation (204 compared with 14 μV) and QTc prolongation (136 compared with 76 ms). Both parameters rapidly normalized on reperfusion, demonstrating that electrocardiography was important for validating correct ligation and reperfusion. In addition, electrocardiography predicted the severity of the myocardial damage induced by ischemia. Our results show that electrocardiographic changes present after 30-min ischemia were reversed on reperfusion; however, prolonged ischemia induced pathologic electrocardiographic patterns that remained even after reperfusion. The mouse model of myocardial ischemia–reperfusion can be improved by using electrocardiography to validate ligation and reperfusion during surgery and to predict the severity of infarction. PMID:21262130

  9. The origins of electrocardiography in Poland

    PubMed Central

    2015-01-01

    The progress of science and technology in the 19th century enabled better understanding of the electrical activity that occurs during a heartbeat. However, it was only the construction and introduction of the galvanometer that cleared the way for appropriate experimental and clinical studies. Marey, Waller, Wenckebach, Einthoven, and Pardee are just examples of the world's pioneers of electrocardiography. Polish researchers, including Cybulski, Eiger, Rzętkowski, Surzycki, and Latkowski, also contributed to the development of this area of study. The following article is a review aiming to reconstruct the origins of electrocardiography in Poland, both as a measurement method used in experiments and as a diagnostic tool in clinical studies conducted in the years preceding the outbreak of World War I. PMID:26336508

  10. Recommendations for the standardization and interpretation of the electrocardiogram. Part II: Electrocardiography diagnostic statement list. A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society.

    PubMed

    Mason, Jay W; Hancock, E William; Gettes, Leonard S

    2007-03-01

    This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.

  11. Transient abnormal Q waves during exercise electrocardiography

    PubMed Central

    Alameddine, F F; Zafari, A M

    2004-01-01

    Myocardial ischaemia during exercise electrocardiography is usually manifested by ST segment depression or elevation. Transient abnormal Q waves are rare, as Q waves indicate an old myocardial infarction. The case of a patient with exercise induced transient abnormal Q waves is reported. The potential mechanisms involved in the development of such an abnormality and its clinical implications are discussed. PMID:14676264

  12. Future of computerised electrocardiography.

    PubMed Central

    Meijler, F L; Robles de Medina, E O; Helder, J C

    1980-01-01

    The advent of computerised electrocardiography has been of prime importance for the storage and retrieval of data, but none of the available systems is of universal application for analysis of patterns. Future needs require hierarchical systems of increasing degrees of complexity, depending on the source of requests, and there should be appropriate provision for review by cardiologists before the final report is issued. PMID:7000098

  13. Conduct a Cost Effectiveness Study of Postgraduate Medical Education Programs. Part I, Part II (Appendixes). Final Report.

    ERIC Educational Resources Information Center

    Manning, Phillip R.; And Others

    To gather data on the effects of different modes of instruction on physician achievement in plotting mean P, O, RS, and T receptiors in electrocardiography, researchers chose a random sample of physicians who had taken a correspondence course on electrocardiography during the previous 5 years from the University of Southern California School of…

  14. Effects of web-based electrocardiography simulation on strategies and learning styles.

    PubMed

    Granero-Molina, José; Fernández-Sola, Cayetano; López-Domene, Esperanza; Hernández-Padilla, José Manuel; Preto, Leonel São Romão; Castro-Sánchez, Adelaida María

    2015-08-01

    To identify the association between the use of web simulation electrocardiography and the learning approaches, strategies and styles of nursing degree students. A descriptive and correlational design with a one-group pretest-posttest measurement was used. The study sample included 246 students in a Basic and Advanced Cardiac Life Support nursing class of nursing degree. No significant differences between genders were found in any dimension of learning styles and approaches to learning. After the introduction of web simulation electrocardiography, significant differences were found in some item scores of learning styles: theorist (p < 0.040), pragmatic (p < 0.010) and approaches to learning. The use of a web electrocardiogram (ECG) simulation is associated with the development of active and reflexive learning styles, improving motivation and a deep approach in nursing students.

  15. Recommendations for the standardization and interpretation of the electrocardiogram: part II: Electrocardiography diagnostic statement list: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: endorsed by the International Society for Computerized Electrocardiology.

    PubMed

    Mason, Jay W; Hancock, E William; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Josephson, Mark; Kligfield, Paul; Kors, Jan A; Macfarlane, Peter; Pahlm, Olle; Mirvis, David M; Okin, Peter; Rautaharju, Pentti; Surawicz, Borys; van Herpen, Gerard; Wagner, Galen S; Wellens, Hein

    2007-03-13

    This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.

  16. Recommendations for the standardization and interpretation of the electrocardiogram: part II: electrocardiography diagnostic statement list a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society Endorsed by the International Society for Computerized Electrocardiology.

    PubMed

    Mason, Jay W; Hancock, E William; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Josephson, Mark; Kligfield, Paul; Kors, Jan A; Macfarlane, Peter; Pahlm, Olle; Mirvis, David M; Okin, Peter; Rautaharju, Pentti; Surawicz, Borys; van Herpen, Gerard; Wagner, Galen S; Wellens, Hein

    2007-03-13

    This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.

  17. Discussion of "Computational Electrocardiography: Revisiting Holter ECG Monitoring".

    PubMed

    Baumgartner, Christian; Caiani, Enrico G; Dickhaus, Hartmut; Kulikowski, Casimir A; Schiecke, Karin; van Bemmel, Jan H; Witte, Herbert

    2016-08-05

    This article is part of a For-Discussion-Section of Methods of Information in Medicine about the paper "Computational Electrocardiography: Revisiting Holter ECG Monitoring" written by Thomas M. Deserno and Nikolaus Marx. It is introduced by an editorial. This article contains the combined commentaries invited to independently comment on the paper of Deserno and Marx. In subsequent issues the discussion can continue through letters to the editor.

  18. Electrocardiography: A Technologist's Guide to Interpretation.

    PubMed

    Tso, Colin; Currie, Geoffrey M; Gilmore, David; Kiat, Hosen

    2015-12-01

    The nuclear medicine technologist works with electrocardiography when performing cardiac stress testing and gated cardiac imaging and when monitoring critical patients. To enhance patient care, basic electrocardiogram interpretation skills and recognition of key arrhythmias are essential for the nuclear medicine technologist. This article provides insight into the anatomy of an electrocardiogram trace, covers basic electrocardiogram interpretation methods, and describes an example case typical in the nuclear medicine environment. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  19. TELEPHONIC ELECTROCARDIOGRAPHY

    PubMed Central

    Hoffman, Irwin; Cosby, Richard S.

    1964-01-01

    Telephonic electrocardiography is a new and useful adjunct to the diagnosis and treatment of cardiovascular disease. It has already demonstrated its great value both in clinical practice and in hospital teaching. It has, however, many other possible roles, for example, in more efficient monitoring after operations on the heart, or in the office monitoring of seriously ill patients with infarction or Adams-Stokes attacks. The availability of increased data in cardiac cases leads automatically to a better understanding of cardiac disease. PMID:14165874

  20. ECG artifact cancellation in surface EMG signals by fractional order calculus application.

    PubMed

    Miljković, Nadica; Popović, Nenad; Djordjević, Olivera; Konstantinović, Ljubica; Šekara, Tomislav B

    2017-03-01

    New aspects for automatic electrocardiography artifact removal from surface electromyography signals by application of fractional order calculus in combination with linear and nonlinear moving window filters are explored. Surface electromyography recordings of skeletal trunk muscles are commonly contaminated with spike shaped artifacts. This artifact originates from electrical heart activity, recorded by electrocardiography, commonly present in the surface electromyography signals recorded in heart proximity. For appropriate assessment of neuromuscular changes by means of surface electromyography, application of a proper filtering technique of electrocardiography artifact is crucial. A novel method for automatic artifact cancellation in surface electromyography signals by applying fractional order calculus and nonlinear median filter is introduced. The proposed method is compared with the linear moving average filter, with and without prior application of fractional order calculus. 3D graphs for assessment of window lengths of the filters, crest factors, root mean square differences, and fractional calculus orders (called WFC and WRC graphs) have been introduced. For an appropriate quantitative filtering evaluation, the synthetic electrocardiography signal and analogous semi-synthetic dataset have been generated. The examples of noise removal in 10 able-bodied subjects and in one patient with muscle dystrophy are presented for qualitative analysis. The crest factors, correlation coefficients, and root mean square differences of the recorded and semi-synthetic electromyography datasets showed that the most successful method was the median filter in combination with fractional order calculus of the order 0.9. Statistically more significant (p < 0.001) ECG peak reduction was obtained by the median filter application compared to the moving average filter in the cases of low level amplitude of muscle contraction compared to ECG spikes. The presented results suggest that the novel method combining a median filter and fractional order calculus can be used for automatic filtering of electrocardiography artifacts in the surface electromyography signal envelopes recorded in trunk muscles. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. Detection of pericardial effusion by chest roentgenography and electrocardiography versus echocardiography.

    PubMed Central

    Manyari, D. E.; Milliken, J. A.; Colwell, B. T.; Burggraf, G. W.

    1978-01-01

    To determine the sensitivity and specificity of chest roentgenography and electrocardiography in the detection of pericardial effusion, echocardiography was used as the diagnostic standard. Chest roentgenograms and electrocardiograms of 124 patients, 57 of whom had pericardial effusion, were read without knowledge of the echocardiographic interpretation. The sensitivity of roentgenographic diagnosis was low (20%), as was that of diagnosis from decreased voltage on the electrocardiogram (26%). The specificity of the chest roentgenogram was 89% and that of the low-voltage electrocardiogram 97%. The high specificity of the low-voltage electrocardiogram may have been due in part to the exclusion of obese and emphysematous subjects from the study. When cardiomegaly detected roentgenographically or a low-voltage electrocardiogram or both were considered as evidence of pericardial effusion, sensitivity improved to 82% but specificity declined to 29%. It is concluded the chest roentgenography and electrocardiography are unsatisfactory as screening investigations for the detection of pericardial effusion. Images FIG. 1 FIG. 2 FIG. 3 PMID:688146

  2. A Unique Digital Electrocardiographic Repository for the Development of Quantitative Electrocardiography and Cardiac Safety: The Telemetric and Holter ECG Warehouse (THEW)

    PubMed Central

    Couderc, Jean-Philippe

    2010-01-01

    The sharing of scientific data reinforces open scientific inquiry; it encourages diversity of analysis and opinion while promoting new research and facilitating the education of next generations of scientists. In this article, we present an initiative for the development of a repository containing continuous electrocardiographic information and their associated clinical information. This information is shared with the worldwide scientific community in order to improve quantitative electrocardiology and cardiac safety. First, we present the objectives of the initiative and its mission. Then, we describe the resources available in this initiative following three components: data, expertise and tools. The Data available in the Telemetric and Holter ECG Warehouse (THEW) includes continuous ECG signals and associated clinical information. The initiative attracted various academic and private partners whom expertise covers a large list of research arenas related to quantitative electrocardiography; their contribution to the THEW promotes cross-fertilization of scientific knowledge, resources, and ideas that will advance the field of quantitative electrocardiography. Finally, the tools of the THEW include software and servers to access and review the data available in the repository. To conclude, the THEW is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. It is a new repository designed to complement the existing ones such as Physionet, the AHA-BIH Arrhythmia Database, and the CSE database. The THEW hosts unique datasets from clinical trials and drug safety studies that, so far, were not available to the worldwide scientific community. PMID:20863512

  3. Multi-channel non-invasive fetal electrocardiography detection using wavelet decomposition

    NASA Astrophysics Data System (ADS)

    Almeida, Javier; Ruano, Josué; Corredor, Germán.; Romo-Bucheli, David; Navarro-Vargas, José Ricardo; Romero, Eduardo

    2017-11-01

    Non-invasive fetal electrocardiography (fECG) has attracted the medical community because of the importance of fetal monitoring. However, its implementation in clinical practice is challenging: the fetal signal has a low Signal- to-Noise-Ratio and several signal sources are present in the maternal abdominal electrocardiography (AECG). This paper presents a novel method to detect the fetal signal from a multi-channel maternal AECG. The method begins by applying filters and signal detrending the AECG signals. Afterwards, the maternal QRS complexes are identified and subtracted. The residual signals are used to detect the fetal QRS complex. Intervals of these signals are analyzed by using a wavelet decomposition. The resulting representation feds a previously trained Random Forest (RF) classifier that identifies signal intervals associated to fetal QRS complex. The method was evaluated on a public available dataset: the Physionet2013 challenge. A set of 50 maternal AECG records were used to train the RF classifier. The evaluation was carried out in signals intervals extracted from additional 25 maternal AECG. The proposed method yielded an 83:77% accuracy in the fetal QRS complex classification task.

  4. Non-responders to cardiac resynchronization therapy: Insights from multimodality imaging and electrocardiography. A brief review.

    PubMed

    Carità, Patrizia; Corrado, Egle; Pontone, Gianluca; Curnis, Antonio; Bontempi, Luca; Novo, Giuseppina; Guglielmo, Marco; Ciaramitaro, Gianfranco; Assennato, Pasquale; Novo, Salvatore; Coppola, Giuseppe

    2016-12-15

    Cardiac resynchronization therapy (CRT) is a successful strategy for heart failure (HF) patients. The pre-requisite for the response is the evidence of electrical dyssynchrony on the surface electrocardiogram usually as left bundle branch block (LBBB). Non-response to CRT is a significant problem in clinical practice. Patient selection, inadequate delivery and sub-optimal left ventricle lead position may be important causes. In an effort to improve CRT response multimodality imaging (especially echocardiography, computed tomography and cardiac magnetic resonance) could play a decisive role and extensive literature has been published on the matter. However, we are so far from routinary use in clinical practice. Electrocardiography (with respect to left ventricle capture and QRS narrowing) may represent a simple and low cost approach for early prediction of potential non-responder, with immediate practical implications. This brief review covers the current recommendations for CRT in HF patients with particular attention to the potential benefits of multimodality imaging and electrocardiography in improving response rate. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. [Comparative analysis of parameters of corrected and uncorrected QT-interval dispersion of magneto-, electrocardiography and isomagnetic maps in patients with ischemic heart disease].

    PubMed

    Shabalin, A V; Tret'iakova, T V; Kuznetsov, A A; Motorin, S V; Golyshev, N V

    2002-01-01

    To compare possibilities of magnetocardiography (MCG) and electrocardiography for assessment of regional dispersion of ventricular recovery time using parameters of corrected and uncorrected QT-interval dispersion (DQTs and DQT). Twenty three patients with class II angina pectoris including 11 patients with history of myocardial infarction (MI) and 13 practically healthy subjects. Mean DQT and DQTc were significantly higher (p<0.005) in patients than in healthy subjects according to both techniques. Values of DQT and DQTc obtained by MCG were higher in patients with history of MI compared with those without MI (p=0.006 and 0.02, respectively). There was a significant positive correlation between age and DQT and DQTc determined by electrocardiography. Mean number of T-wave dipoles was significantly higher in patients than in healthy subjects. Substantial positive correlation was found between number of T-wave dipoles on isomagnetic maps and age in both patients and healthy people. The method of MCG gave supplementary information on the state of ventricular depolarization in patients with ischemic heart disease.

  6. [Circulatory Function Tests for Home & Community Use.

    PubMed

    Shimetani, Naoto

    2016-05-01

    Currently, the main circulatory function-testing tools for home use are blood pressure monitors and elec- trocardiography devices. Just like blood pressure monitors that are already widespread for home use, some devices with an electrocardiographic function have recently become available for purchase for personal use by the general public. On the other hand, clinic equipment on loan from doctors to patients in need can perform circulatory function tests like 24-hour ambulatory blood pressure monitoring (ABPM), Holter monitoring, and real-time electrocardiography. We introduce the actual clinical usage of ABPM and real-time electro- cardiography, and discuss the usefulness of these procedures. ABPM uses a blood pressure measurement device worn on the body for 24 hours a day to measure blood pressure at regular intervals. This makes it possible to check blood pressure changes throughout the day in a way in which conventional home-use blood pressure monitors cannot, like during sleep. This method al- lows the identification of masked hypertension like early-morning and nocturnal hypertension, stress hyper- tension including workplace hypertension, and white coat hypertension that only occurs in the doctor's office. Under routine care, there are few opportunities to perform electrocardiography at the time a patient is experiencing symptoms. Now, real-time electrocardiography has begun to be used in routine care, and pa- tients can record an electrocardiogram by themselves anytime, anywhere, and send the data by telephone or the Internet for analysis and diagnosis. Transmission-capable electrocardiography devices can play an im- portant role in the event of dangerous symptoms like arrhythmia, angina, or acute myocardial infarction. The spread of ABPM and event heart monitors is likely to make the early treatment and prevention of stroke and heart disease possible. We are expecting rapid development in this field in the future.

  7. Factors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement

    PubMed Central

    Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying

    2015-01-01

    Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758

  8. Noninvasive Fetal Electrocardiography Part II: Segmented-Beat Modulation Method for Signal Denoising

    PubMed Central

    Agostinelli, Angela; Sbrollini, Agnese; Burattini, Luca; Fioretti, Sandro; Di Nardo, Francesco; Burattini, Laura

    2017-01-01

    Background: Fetal well-being evaluation may be accomplished by monitoring cardiac activity through fetal electrocardiography. Direct fetal electrocardiography (acquired through scalp electrodes) is the gold standard but its invasiveness limits its clinical applicability. Instead, clinical use of indirect fetal electrocardiography (acquired through abdominal electrodes) is limited by its poor signal quality. Objective: Aim of this study was to evaluate the suitability of the Segmented-Beat Modulation Method to denoise indirect fetal electrocardiograms in order to achieve a signal-quality at least comparable to the direct ones. Method: Direct and indirect recordings, simultaneously acquired from 5 pregnant women during labor, were filtered with the Segmented-Beat Modulation Method and correlated in order to assess their morphological correspondence. Signal-to-noise ratio was used to quantify their quality. Results: Amplitude was higher in direct than indirect fetal electrocardiograms (median:104 µV vs. 22 µV; P=7.66·10-4), whereas noise was comparable (median:70 µV vs. 49 µV, P=0.45). Moreover, fetal electrocardiogram amplitude was significantly higher than affecting noise in direct recording (P=3.17·10-2) and significantly in indirect recording (P=1.90·10-3). Consequently, signal-to-noise ratio was initially higher for direct than indirect recordings (median:3.3 dB vs. -2.3 dB; P=3.90·10-3), but became lower after denoising of indirect ones (median:9.6 dB; P=9.84·10-4). Eventually, direct and indirect recordings were highly correlated (median: ρ=0.78; P<10-208), indicating that the two electrocardiograms were morphologically equivalent. Conclusion: Segmented-Beat Modulation Method is particularly useful for denoising of indirect fetal electrocardiogram and may contribute to the spread of this noninvasive technique in the clinical practice. PMID:28567129

  9. Design and Development of Intelligent Electrodes for Future Digital Health Monitoring: A Review

    NASA Astrophysics Data System (ADS)

    Khairuddin, A. M.; Azir, K. N. F. Ku; Kan, P. Eh

    2018-03-01

    Electrodes are sensors used in electrocardiography (ECG) monitoring system to diagnose heart diseases. Over the years, diverse types of electrodes have been designed and developed to improve ECG monitoring system. However, more recently, with the technological advances and capabilities from the Internet of Things (IoT), cloud computing and data analytics in personalized healthcare, researchers are attempting to design and develop more effective as well as flexible ECG devices by using intelligent electrodes. This paper reviews previous works on electrodes used in electrocardiography (ECG) monitoring devices to identify the key ftures for designing and developing intelligent electrodes in digital health monitoring devices.

  10. Carbon Tube Electrodes for Electrocardiography-Gated Cardiac Multimodality Imaging in Mice

    PubMed Central

    Choquet, Philippe; Goetz, Christian; Aubertin, Gaelle; Hubele, Fabrice; Sannié, Sébastien; Constantinesco, André

    2011-01-01

    This report describes a simple design of noninvasive carbon tube electrodes that facilitates electrocardiography (ECG) in mice during cardiac multimodality preclinical imaging. Both forepaws and the left hindpaw, covered by conductive gel, of mice were placed into the openings of small carbon tubes. Cardiac ECG-gated single-photon emission CT, X-ray CT, and MRI were tested (n = 60) in 20 mice. For all applications, electrodes were used in a warmed multimodality imaging cell. A heart rate of 563 ± 48 bpm was recorded from anesthetized mice regardless of the imaging technique used, with acquisition times ranging from 1 to 2 h. PMID:21333165

  11. Malignant arrhythmia as the first manifestation of Wolff-Parkinson-White syndrome: a case with minimal preexcitation on electrocardiography.

    PubMed

    Gungor, B; Alper, A T

    2013-09-01

    Wolff-Parkinson-White (WPW) syndrome is defined as the presence of an accessory atrioventricular pathway which is manifested as delta waves and short PR interval on electrocardiography (ECG). However, some WPW cases do not have typical findings on ECG and may remain undiagnosed unless palpitations occur. Sudden cardiac death may be the first manifestation of WPW and develops mostly secondary to degeneration of atrial fibrillation into ventricular fibrillation. In this report, we present a case of undiagnosed WPW with minimal preexcitation on ECG and who suffered an episode of malignant arrhythmia as the first manifestation of the disease.

  12. Noninvasive fetal electrocardiography following intermittent umbilical cord occlusion in the preterm ovine fetus.

    PubMed

    Cleal, J K; Thomas, M; Hanson, M A; Paterson-Brown, S; Gardiner, H M; Green, L R

    2010-03-01

    To investigate whether a noninvasive fetal electrocardiography (fECG) system can identify cardiovascular responses to fetal hypoxaemia and validate the results using standard invasive fECG monitoring techniques. Prospective cohort study. Biological research facilities at The University of Southampton. Late gestation ovine fetuses; n = 5. Five fetal lambs underwent implantation of vascular catheters, umbilical cord occluder and invasive ECG chest electrodes under general anaesthesia (3% halothane/O(2)) at 119 days of gestation (term approximately 147 days of gestation). After 5 days of recovery blood pressure, blood gases, glucose and pH were monitored. At 124 and 125 days of gestation following a 10-minute baseline period a 90-second cord occlusion was applied. Noninvasive fetal ECG was recorded from maternal transabdominal electrodes using advanced signal-processing techniques, concurrently with invasive fECG recordings. Comparison of T:QRS ratios of the ECG waveform from noninvasive and invasive fECG monitoring systems. Our fECG monitoring system is able to demonstrate changes in waveforms during periods of hypoxaemia similar to those obtained invasively, which could indicate fetal distress. These findings may indicate a future use for noninvasive electrocardiography during human fetal monitoring both before and during labour in term and preterm pregnancies.

  13. A Toolkit for Forward/Inverse Problems in Electrocardiography within the SCIRun Problem Solving Environment

    PubMed Central

    Burton, Brett M; Tate, Jess D; Erem, Burak; Swenson, Darrell J; Wang, Dafang F; Steffen, Michael; Brooks, Dana H; van Dam, Peter M; Macleod, Rob S

    2012-01-01

    Computational modeling in electrocardiography often requires the examination of cardiac forward and inverse problems in order to non-invasively analyze physiological events that are otherwise inaccessible or unethical to explore. The study of these models can be performed in the open-source SCIRun problem solving environment developed at the Center for Integrative Biomedical Computing (CIBC). A new toolkit within SCIRun provides researchers with essential frameworks for constructing and manipulating electrocardiographic forward and inverse models in a highly efficient and interactive way. The toolkit contains sample networks, tutorials and documentation which direct users through SCIRun-specific approaches in the assembly and execution of these specific problems. PMID:22254301

  14. Exercise stress test

    MedlinePlus

    Exercise ECG; ECG - exercise treadmill; EKG - exercise treadmill; Stress ECG; Exercise electrocardiography; Stress test - exercise treadmill; CAD - treadmill; Coronary artery disease - treadmill; Chest pain - treadmill; Angina - treadmill; ...

  15. [Challenges to implementation of the ECG reading center in ELSA-Brasil].

    PubMed

    Ribeiro, Antonio Luiz; Pereira, Samuel Vianney da Cunha; Bergmann, Kaiser; Ladeira, Roberto Marini; Oliveira, Rackel Aguiar Mendes; Lotufo, Paulo A; Mill, José Geraldo; Barreto, Sandhi Maria

    2013-06-01

    Electrocardiography is an established low-cost method of cardiovascular assessment, utilized for decades large epidemiological studies. Nonetheless, its use in large epidemiological studies presents challenges, especially when seeking to develop a reading center. This article describes the process, difficulties and challenges of implementing an electrocardiogram reading center in Brazilian Longitudinal Study for Adult Health (ELSA-Brasil). Among the issues discussed, we have emphasized: the criteria for selection of the electrocardiography machine and the central for storage and management of the machines; the required personnel; the procedures for acquisition and transmission of electrocardiographs to the Reading Center; coding systems, with emphasis on the Minnesota code; ethical and practical issues regarding the delivery of reports to study participants; and aspects related to quality control.

  16. A Carbamazepine-induced Brugada-type Electrocardiographic Pattern in a Patient with Schizophrenia

    PubMed Central

    Ota, Hisanobu; Kawamura, Yuichiro; Sato, Nobuyuki; Hasebe, Naoyuki

    2017-01-01

    We report the case of a 61-year-old man with schizophrenia who was treated with carbamazepine, in whom electrocardiography showed transient Brugada-type ST elevation. He had been hospitalized our hospital's Department of Psychiatry and had been diagnosed with pneumonia. On the following day, electrocardiography showed coved-type ST elevation in the right precordial leads and a blood examination revealed that the patient's carbamazepine concentration was at the upper limit of the standard range, as well as hypothyroidism. The patient's electrocardiogram normalized after the withdrawal of carbamazepine. We demonstrated that the patient's carbamazepine concentration-and not hypothyroidism-was associated with the serial electrocardiographic changes by monitoring the patient's blood concentration of carbamazepine and his thyroid function. PMID:29142189

  17. Comparison of the measurement of heart rate in adult free-range chickens (Gallus domesticus) by auscultation and electrocardiography.

    PubMed

    Smith, C F; Gavaghan, B J; McSweeney, D; Powell, V; Lisle, A

    2014-12-01

    To compare the heart rates of adult free-range chickens (Gallus domesticus) measured by auscultation with a stethoscope with those measured simultaneously using electrocardiography (ECG). With each bird in a standing position, estimation of the heart rate was performed by placing a mark on paper for every 4 beats for roosters and 8 beats for hens as detected by auscultation over 30 s, while simultaneous ECG was performed. Heart rates measured by auscultation showed a high correlation (r = 0.97) with those measured by ECG. There was a high correlation between the heart rates of adult free-range chickens measured by auscultation with a stethoscope and those measured simultaneously using ECG. © 2014 Australian Veterinary Association.

  18. Screening versus routine practice in detection of atrial fibrillation in patients aged 65 or over: cluster randomised controlled trial

    PubMed Central

    Fitzmaurice, David A; Jowett, Sue; Mant, Jonathon; Murray, Ellen T; Holder, Roger; Raftery, J P; Bryan, S; Davies, Michael; Lip, Gregory Y H; Allan, T F

    2007-01-01

    Objectives To assess whether screening improves the detection of atrial fibrillation (cluster randomisation) and to compare systematic and opportunistic screening. Design Multicentred cluster randomised controlled trial, with subsidiary trial embedded within the intervention arm. Setting 50 primary care centres in England, with further individual randomisation of patients in the intervention practices. Participants 14 802 patients aged 65 or over in 25 intervention and 25 control practices. Interventions Patients in intervention practices were randomly allocated to systematic screening (invitation for electrocardiography) or opportunistic screening (pulse taking and invitation for electrocardiography if the pulse was irregular). Screening took place over 12 months in each practice from October 2001 to February 2003. No active screening took place in control practices. Main outcome measure Newly identified atrial fibrillation. Results The detection rate of new cases of atrial fibrillation was 1.63% a year in the intervention practices and 1.04% in control practices (difference 0.59%, 95% confidence interval 0.20% to 0.98%). Systematic and opportunistic screening detected similar numbers of new cases (1.62% v 1.64%, difference 0.02%, −0.5% to 0.5%). Conclusion Active screening for atrial fibrillation detects additional cases over current practice. The preferred method of screening in patients aged 65 or over in primary care is opportunistic pulse taking with follow-up electrocardiography. Trial registration Current Controlled Trials ISRCTN19633732. PMID:17673732

  19. The Validity of Adding ECG to the Preparticipation Screening of Athletes An Evidence Based Literature Review

    PubMed Central

    Alattar, A; Maffulli, N

    2015-01-01

    Objective: To review the available evidence establishing the validity of adding electrocardiogram to the preparticipation cardiac screening in athletes. Data Sources: MEDLINE and CINAHL databases were searched. Additional references from the bibliographies of retrieved articles were also reviewed and experts in the area were contacted. Selection Criteria: Only original research articles seeking to establish the use of electrocardiography followed by second line investigations in athletes under 36 years of age were reviewed. Search Result and Quality Assessment: The initial literature search identified 226 papers. Of these, 16 original articles (all type II evidence—population-based clinical studies) met the selection criteria and directly related to the use of electrocardiography in athletes cardiac screening. The methodological qualities of included studies were assessed using the Downs and Black checklist. Conclusion: Screening with electrocardiography represents best clinical practice to prevent or reduce the risk of sudden cardiac death in athletes. It significantly improves the sensitivity of history and physical examination alone; it has reasonable specificity and excellent negative predictive value; and it is cost-effective. Future studies must be large, multicentre, multination, prospective trials powered to determine how different screening options affect the incidence of sudden cardiac death. Efforts should also be targeted toward secondary prevention of sudden cardiac death with pitch side cardiac resuscitation and the immediate use of defibrillator. PMID:25674543

  20. Heart Rate and Electrocardiography Monitoring in Mice

    PubMed Central

    Ho, David; Zhao, Xin; Gao, Shumin; Hong, Chull; Vatner, Dorothy E.; Vatner, Stephen F.

    2011-01-01

    The majority of current cardiovascular research involves studies in genetically engineered mouse models. The measurement of heart rate is central to understanding cardiovascular control under normal conditions, with altered autonomic tone, superimposed stress or disease states, both in wild type mice as well as those with altered genes. Electrocardiography (ECG) is the “gold standard” using either hard wire or telemetry transmission. In addition, heart rate is measured or monitored from the frequency of the arterial pressure pulse or cardiac contraction, or by pulse oximetry. For each of these techniques, discussions of materials and methods, as well as advantages and limitations are covered. However, only the direct ECG monitoring will determine not only the precise heart rates but also whether the cardiac rhythm is normal or not. PMID:21743842

  1. Vision Loss, Sudden

    MedlinePlus

    ... present. CT = computed tomography; ECG = electrocardiography; ESR = erythrocyte sedimentation rate; MRI = magnetic resonance imaging. Spotlight on Aging: ... swelling is seen during the eye examination. Erythrocyte sedimentation rate (ESR) and C-reactive protein level (blood ...

  2. Digitalis toxicity

    MedlinePlus

    ... Concepts and Clinical Practice . 8th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 152. Goldberger AL, Goldberger ZD, ... Electrocardiography: A Simplified Approach . 8th ed. Philadelphia, PA: Elsevier Saunders; 2013:chap 18. Nelson LS, Ford MD. ...

  3. The Electrocardiogram and Ischemic Heart Disease in Aircraft Pilots

    PubMed Central

    Manning, G. W.

    1965-01-01

    A review of the Royal Canadian Air Force electrocardiographic (ECG) program for selection of aircrew and detection of coronary disease in trained aircrew is presented. Twenty reported cases of death due to coronary disease in pilots while at the controls of an aircraft are reviewed. The use of routine electrocardiography in the selection of aircrew has proved to be of considerable value, particularly in view of the high cost of training. The ECG continues to be our most sensitive means of detecting asymptomatic coronary disease in aircrew personnel. It is apparent that from both the military and commercial standpoint the incidence of aircraft accidents due to coronary disease is extremely small. This is due in large part to the careful medical supervision of flying personnel including the routine use of electrocardiography in the assessment of flying fitness of aircrew. PMID:14323657

  4. Afebrile seizures and electrocardiography abnormality: an unusual presentation of nutritional rickets.

    PubMed

    Gad, Kg; Khan, Ma; Mahmood, K

    2014-08-01

    Nutritional rickets is not uncommon in the western world and has been reported widely. Occasionally, children have presented to paediatrics with afebrile seizures secondary to hypocalcaemia due to hypovitaminosis D. However, association of nutritional rickets with electrocardiography changes and prolonged QT interval is not well documented. It is a rare, potentially serious and yet easy-to-treat complication as shown in our case. Our case also highlights the importance of awareness and education of both parents and clinicians regarding this relatively common but easily treatable condition. We report a case of undiagnosed nutritional rickets presenting as 'Afebrile' seizure in a seven-month-old Somali girl. Her initial blood work-up showed low ionised calcium (0.8 mmol/l) on blood gas sampling, confirmed by laboratory result (adjusted 1.49 mmol/l). She had prolonged QTc on electrocardiography which reverted to normal with treatment. She was treated with intravenous as well as oral calcium after which she had no further seizures. We present a unique case of nutritional rickets-associated hypocalcaemia. This case highlights the resurgence of nutritional rickets in western societies. We need to keep this disease in our list of diagnoses as it is a potentially serious and yet easily treatable disease. We should be more vigilant for screening ethnic minorities as alarmingly high rates of hypovitaminosis D have been found in ethnic minorities living in Great Britain. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. Usefulness of echocardiography in preparticipation screening of competitive athletes.

    PubMed

    Grazioli, Gonzalo; Merino, Beatriz; Montserrat, Silvia; Vidal, Bàrbara; Azqueta, Manel; Pare, Carles; Sarquella-Brugada, Georgia; Yangüas, Xavier; Pi, Ramon; Til, Lluis; Escoda, Jaume; Brugada, Josep; Sitges, Marta

    2014-09-01

    Despite the established diagnostic value of the electrocardiogram in preparticipation screening of athletes, some cardiac structural changes can be missed, particularly in early disease stages. The aim of this study was to evaluate the prevalence of cardiac structural changes via the systematic use of echocardiography in preparticipation screening of competitive athletes. Professional athletes or participants in a competitive athletic program underwent a screening that included family and personal medical history, physical examination, electrocardiography, exercise testing, and Doppler echocardiography. A total of 2688 athletes (67% men; mean age [standard deviation], 21 [10] years) were included. Most of the echocardiographic evaluations (92.5%) were normal and only 203 (7.5%) showed changes; the most frequent change was left ventricular hypertrophy, seen in 50 athletes (1.8%). Cessation of athletic activity was indicated in 4 athletes (0.14%): 2 for hypertrophic cardiomyopathy (electrocardiography had shown changes that did not meet diagnostic criteria), 1 pectus excavatum with compression of the right ventricle, and 1 significant pulmonary valve stenosis; the rest of the changes did not entail cessation of athletic activity and only indicated periodic monitoring. Although rare, some cardiac structural changes can be missed on physical examination and electrocardiography; in contrast, they are easily recognized with echocardiography. These findings suggest the use of echocardiography in at least the first preparticipation screening of competitive athletes to improve the effectiveness of programs aimed at preventing sudden death in athletes. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  6. The pre-operative electrocardiogram: an assessment.

    PubMed

    Paterson, K R; Caskie, J P; Galloway, D J; McArthur, K; McWhinnie, D L

    1983-04-01

    Electrocardiography is of limited value in pre-operative screening for cardiac disease. A short questionnaire has been shown to be helpful in assessing cardiac status and could permit a 30% reduction in the number of pre-operative ECGs performed.

  7. Secure chaotic transmission of electrocardiography signals with acousto-optic modulation under profiled beam propagation.

    PubMed

    Almehmadi, Fares S; Chatterjee, Monish R

    2015-01-10

    Electrocardiography (ECG) signals are used for both medical purposes and identifying individuals. It is often necessary to encrypt this highly sensitive information before it is transmitted over any channel. A closed-loop acousto-optic hybrid device acting as a chaotic modulator is applied to ECG signals to achieve this encryption. Recently improved modeling of this approach using profiled optical beams has shown it to be very sensitive to key parameters that characterize the encryption and decryption process, exhibiting its potential for secure transmission of analog and digital signals. Here the encryption and decryption is demonstrated for ECG signals, both analog and digital versions, illustrating strong encryption without significant distortion. Performance analysis pertinent to both analog and digital transmission of the ECG waveform is also carried out using output signal-to-noise, signal-to-distortion, and bit-error-rate measures relative to the key parameters and presence of channel noise in the system.

  8. Development and clinical study of mobile 12-lead electrocardiography based on cloud computing for cardiac emergency.

    PubMed

    Fujita, Hideo; Uchimura, Yuji; Waki, Kayo; Omae, Koji; Takeuchi, Ichiro; Ohe, Kazuhiko

    2013-01-01

    To improve emergency services for accurate diagnosis of cardiac emergency, we developed a low-cost new mobile electrocardiography system "Cloud Cardiology®" based upon cloud computing for prehospital diagnosis. This comprises a compact 12-lead ECG unit equipped with Bluetooth and Android Smartphone with an application for transmission. Cloud server enables us to share ECG simultaneously inside and outside the hospital. We evaluated the clinical effectiveness by conducting a clinical trial with historical comparison to evaluate this system in a rapid response car in the real emergency service settings. We found that this system has an ability to shorten the onset to balloon time of patients with acute myocardial infarction, resulting in better clinical outcome. Here we propose that cloud-computing based simultaneous data sharing could be powerful solution for emergency service for cardiology, along with its significant clinical outcome.

  9. Cardiac function in children with premature ventricular contractions: the effect of omega-3 polyunsaturated fatty acid supplementation.

    PubMed

    Oner, Taliha; Ozdemir, Rahmi; Doksöz, Onder; Genc, Dildar B; Guven, Baris; Demirpence, Savas; Yilmazer, Murat M; Yozgat, Yilmaz; Mese, Timur; Tavli, Vedide

    2018-07-01

    Premature ventricular contractions are accepted as benign in structurally normal hearts. However, reversible cardiomyopathy can sometimes develop. Omega-3 polyunsaturated fatty acids have anti-arrhythmic properties in animals and humans.AimWe evaluated left ventricular function in children with premature ventricular contractions with normal cardiac anatomy and assessed the impact of omega-3 fatty acid supplementation on left ventricular function in a prospective trial. A total of 25 patients with premature ventricular contraction, with more than 2% premature ventricular contractions on 24-hour Holter electrocardiography, and 30 healthy patients were included into study. All patients underwent electrocardiography, left ventricular M-mode echocardiography, and myocardial performance index testing. Patients with premature ventricular contraction were given omega-3 fatty acids at a dose of 1 g/day for 3 months, and control echocardiography and 24-hour Holter electrocardiography were performed. Neither placebo nor omega-3 fatty acids were given to the control group. Compared with the values of the control group, the patients with premature ventricular contraction had significantly lower fractional shortening. The myocardial performance index decreased markedly in the patient groups. The mean heart rate and mean premature ventricular contraction percentage of Group 2 significantly decreased in comparison with their baseline values after the omega-3 supplementation. In conclusion, premature ventricular contractions can lead to systolic cardiac dysfunction in children. Omega-3 supplementation may improve cardiac function in children with premature ventricular contractions. This is the first study conducted in children to investigate the possible role of omega-3 fatty acid supplementation on treatment of premature ventricular contractions.

  10. Screening for Coronary Heart Disease with Electrocardiography

    MedlinePlus

    ... independent group of national experts in prevention and evidence-based medicine. The Task Force works to improve the health of all Americans by making evidence-based recommendations about clinical ... or preventive medicines. The recommendations apply to people with no signs ...

  11. Joint Soviet-American experiment on hypokinesia: Experimental results

    NASA Technical Reports Server (NTRS)

    Burovskiy, N. N.

    1979-01-01

    Comprehensive results are reported from the Soviet portion of a joint Soviet-American experiment involving hypokinesia. The main emphases are on chemical analyses of blood and urine, functional tests, and examination of the cardiovascular system by electrocardiography, echocardiography, and plethysmography.

  12. Hypertrophic Cardiomyopathy: Practical Steps for Preventing Sudden Death.

    ERIC Educational Resources Information Center

    Maron, Barry J.

    2002-01-01

    Hypertrophic cardiomyopathy (HCM) is a rare cause of death among athletes, with deaths occurring in young, apparently healthy people. Differentiating HCM from conditioning hypertrophy is challenging. Routine detection involves family history, physical examination, electrocardiography, and echocardiography. Keys to differential diagnosis include…

  13. Epsilon Waves Detected by Various Electrocardiographic Recording Methods in Patients with Arrhythmogenic Right Ventricular Cardiomyopathy

    PubMed Central

    Wang, Jing; Yang, Bing; Chen, Hongwu; Ju, Weizhu; Chen, Kai; Zhang, Fengxiang; Cao, Kejiang; Chen, Minglong

    2010-01-01

    We analyzed the shape and distribution of epsilon waves by 3 various methods of electrocardiographic recording in patients with arrhythmogenic right ventricular cardiomyopathy. Thirty-two patients who met recognized diagnostic criteria for arrhythmogenic right ventricular cardiomyopathy were included in this study (24 men and 8 women; mean age, 42.3 ± 12.9 yr). Epsilon waves were detected by standard 12-lead electrocardiography (S-ECG), right-sided precordial lead electrocardiography (R-ECG), and Fontaine bipolar precordial lead electrocardiography (F-ECG). We found 3 types of epsilon waves: wiggle waves, small spike waves, and smooth potential waves that formed an atypical prolonged R' wave. The most common configuration was small spiked waves. In some circumstances, epsilon waves were evident in some leads (especially in leads V1 through V3), but notches were recorded in the other leads during the corresponding phase. These waves could be detected only by S-ECG in 1 patient, R-ECG in 3 patients, and F-ECG in 5 patients; the rates of epsilon-wave detection by these 3 methods were 38% (12/32), 38% (12/32), and 50% (16/32), respectively. However, the detection rate using combined methods was significantly higher than that by S-ECG alone (SF-ECG 56% vs S-ECG 38%, P = 0.0312; and SRF-ECG 66% vs S-ECG 38%, P = 0.0039). In addition, the rate of widespread T-wave inversion (exceeding V3) was significantly higher in patients with epsilon waves than in those without (48% vs 9%, P = 0.029), as was ventricular tachycardia (95% vs 64%, P = 0.019). These 3 electrocardiographic recording methods should be used in combination to improve the detection rate of epsilon waves. PMID:20844612

  14. Electrocardiography based prediction of hypertrophy pattern and fibrosis amount in hypertrophic cardiomyopathy: comparative study with cardiac magnetic resonance imaging.

    PubMed

    Park, Chul Hwan; Chung, Hyemoon; Kim, Yoonjung; Kim, Jong-Youn; Min, Pil-Ki; Lee, Kyung-A; Yoon, Young Won; Kim, Tae Hoon; Lee, Byoung Kwon; Hong, Bum-Kee; Rim, Se-Joong; Kwon, Hyuck Moon; Choi, Eui-Young

    2018-05-04

    Although, cardiac magnetic resonance imaging (CMR) is a gold standard for risk stratification of hypertrophic cardiomyopathy (HCM), is limited in some situations. We sought to evaluate the predictive power of quantitative electrocardiography in assessing hypertrophy pattern and fibrosis in HCM. Eighty-eight patients with HCM were studied. Voltage of R-S-T waves, number of fragmented QRS (fQRS) complexes, and T wave morphology were measured by 12-lead electrocardiography. Sixteen segmental thickness, late gadolinium enhancement (LGE), native T1, extracellular volume fraction (ECV), and T2, left ventricular (LV) mass and %LGE were measured by CMR. Patterns of LV hypertrophy were classified as pure apical, mixed, or asymmetrical septal hypertrophy. Positive and negative predictive values of biphasic T wave for pure apical type were 70.4 and 63.9%, and the predictive values of precordial negative T wave sums [Formula: see text] 12.5 mm were 69.2 and 79.6%. Precordial S waves, especially Cornell voltage index, were significantly correlated to LV mass index and maximal thickness (p [Formula: see text]0.001). The number of fQRS leads was significantly correlated to %LGE, average ECV, and T2 (all p [Formula: see text]0.001). More than one lead with fQRS could predict [Formula: see text]5% of LGE mass with 58% sensitivity and 63% specificity (p = 0.049, area under the curve = 0.627). However, degree of correlation between maximal thickness and precordial S was poor in cases with fQRS more two leads. T wave morphology and precordial S helps discriminate hypertrophy pattern and maximal hypertrophy, however, in cases with more than two leads of concomitant fQRS, CMR defines fibrosis amount and hypertrophy more accurately.

  15. A novel method of fabricating carbon nanotubes-polydimethylsiloxane composite electrodes for electrocardiography.

    PubMed

    Liu, Benyan; Chen, Yingmin; Luo, Zhangyuan; Zhang, Wenzan; Tu, Quan; Jin, Xun

    2015-01-01

    Polymer-based flexible electrodes are receiving much attention in medical applications due to their good wearing comfort. The current fabrication methods of such electrodes are not widely applied. In this study, polydimethylsiloxane (PDMS) and conductive additives of carbon nanotubes (CNTs) were employed to fabricate composite electrodes for electrocardiography (ECG). A three-step dispersion process consisting of ultrasonication, stirring, and in situ polymerization was developed to yield homogenous CNTs-PDMS mixtures. The CNTs-PDMS mixtures were used to fabricate CNTs-PDMS composite electrodes by replica technology. The influence of ultrasonication time and CNT concentration on polymer electrode performance was evaluated by impedance and ECG measurements. The signal amplitude of the electrodes prepared using an ultrasonication time of 12 h and CNT content of 5 wt% was comparable to that of commercial Ag/AgCl electrodes. The polymer electrodes were easily fabricated by conventional manufacturing techniques, indicating a potential advantage of reduced cost for mass production.

  16. An evaluation of eye tracking technology in the assessment of 12 lead electrocardiography interpretation.

    PubMed

    Breen, Cathal J; Bond, Raymond; Finlay, Dewar

    2014-01-01

    This study investigated eye tracking technology for 12 lead electrocardiography interpretation to Healthcare Scientist students. Participants (n=33) interpreted ten 12 lead ECG recordings and randomized to receive objective individual appraisal on their efforts either by traditional didactic format or by eye tracker software. One hundred percent of participants reported the experience positively at improving their ECG interpretation competency. ECG analysis time ranged between 13.2 and 59.5s. The rhythm strip was the most common lead studied and fixated on for the longest duration (mean 9.9s). Lead I was studied for the shortest duration (mean 0.25s). Feedback using eye tracking data during ECG interpretation did not produce any significant variation between the assessment marks of the study and the control groups (p=0.32). Although the hypothesis of this study was rejected active teaching and early feedback practices are recommended within this discipline. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. A simple device to illustrate the Einthoven triangle.

    PubMed

    Jin, Benjamin E; Wulff, Heike; Widdicombe, Jonathan H; Zheng, Jie; Bers, Donald M; Puglisi, Jose L

    2012-12-01

    The Einthoven triangle is central to the field of electrocardiography, but the concept of cardiac vectors is often a difficult notion for students to grasp. To illustrate this principle, we constructed a device that recreates the conditions of an ECG reading using a battery to simulate the electrical vector of the heart and three voltmeters for the main electrocardiographic leads. Requiring minimal construction with low cost, this device provides hands-on practice that enables students to rediscover the principles of the Einthoven triangle, namely, that the direction of the cardiac dipole can be predicted from the deflections in any two leads and that lead I + lead III = lead II independent of the position of heart's electrical vector. We built a total of 6 devices for classes of 30 students and tested them in the first-year Human Physiology course at the University of California-Davis School of Medicine. Combined with traditional demonstrations with ECG machines, this equipment demonstrated its ability to help medical students obtain a solid foundation of the basic principles of electrocardiography.

  18. Comparison of corrected QT interval as measured on electroencephalography versus 12-lead electrocardiography in children with a history of syncope.

    PubMed

    Massey, Shavonne L; Wise, Marshall S; Madan, Nandini; Carvalho, Karen; Khurana, Divya; Legido, Agustin; Valencia, Ignacio

    2011-11-01

    Long QT syndrome can present with neurological manifestations, including syncope and seizure-like activity. These patients often receive an initial neurologic evaluation, including electroencephalography (EEG). Our previous retrospective study suggested an increased prevalence of prolonged corrected QT interval (QTc) measured during the EEG of patients with syncope. The aim of the current study is to assess the accuracy of the EEG QTc reading compared with the nonsimultaneous 12-lead electrocardiography (ECG) in children with syncope. Abnormal QTc was defined as ≥450 ms in boys, ≥460 ms in girls. Forty-two children were included. There was no significant correlation between QTc readings in the EEG and ECG. EEG failed to identify 2 children with prolonged QTc in the ECG and overestimated the QTc in 3 children with normal QTc in the ECG. This study suggests that interpretation of the QTc segment during an EEG is limited. Further studies with simultaneous EEG and 12-lead ECG are warranted.

  19. Comparison of cardiogoniometry and electrocardiography with perfusion cardiac magnetic resonance imaging and late gadolinium enhancement.

    PubMed

    Birkemeyer, Ralf; Toelg, Ralph; Zeymer, Uwe; Wessely, Rainer; Jäckle, Sebastian; Hairedini, Bajram; Lübke, Mike; Aßfalg, Manfred; Jung, Werner

    2012-12-01

    Cardiogoniometry (CGM) is a spatio-temporal five-lead resting electrocardiographic method utilizing automated analysis. The purpose of this study was to determine CGM's and electrocardiography (ECG)'s accuracy for detecting myocardial ischaemia and/or lesions in comparison with perfusion cardiac magnetic resonance imaging (CMRI) and late gadolinium enhancement (LGE). Forty (n= 40) patients with suspected or known stable coronary artery disease were examined by CGM and resting ECG directly prior to CMRI including adenosine stress perfusion (ASP) and LGE. The investigators visually reading the CMRI were blinded to the CGM and ECG results. Half of the patients (n= 20) had a normal CMRI while the other half presented with either abnormal ASP and/or detectable LGE. Cardiogoniometry yielded an accuracy of 83% (sensitivity 70%) and ECG of 63% (sensitivity 35%) compared with CMRI. In this pilot study CGM compares more favourably than ECG with the detection of ischaemia and/or structural myocardial lesions on CMRI.

  20. Eyewitness to history: Landmarks in the development of computerized electrocardiography.

    PubMed

    Rautaharju, Pentti M

    2016-01-01

    The use of digital computers for ECG processing was pioneered in the early 1960s by two immigrants to the US, Hubert Pipberger, who initiated a collaborative VA project to collect an ECG-independent Frank lead data base, and Cesar Caceres at NIH who selected for his ECAN program standard 12-lead ECGs processed as single leads. Ray Bonner in the early 1970s placed his IBM 5880 program in a cart to print ECGs with interpretation, and computer-ECG programs were developed by Telemed, Marquette, HP-Philips and Mortara. The "Common Standards for quantitative Electrocardiography (CSE)" directed by Jos Willems evaluated nine ECG programs and eight cardiologists in clinically-defined categories. The total accuracy by a representative "average" cardiologist (75.5%) was 5.8% higher than that of the average program (69.7, p<0.001). Future comparisons of computer-based and expert reader performance are likely to show evolving results with continuing improvement of computer-ECG algorithms and changing expertise of ECG interpreters. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. High gain signal averaged electrocardiogram combined with 24 hour monitoring in patients early after myocardial infarction for bedside prediction of arrhythmic events.

    PubMed Central

    Cripps, T; Bennett, E D; Camm, A J; Ward, D E

    1988-01-01

    The value of the high gain, signal averaged electrocardiogram combined with 24 hour electrocardiographic monitoring in the prediction of arrhythmic events was assessed in 159 patients in the first week after myocardial infarction. Eleven patients (7%) suffered arrhythmic events during a mean (SD) of 12 (6) months of follow up (range 2-22, median 13 months). The combination of high gain, signal averaged electrocardiography and 24 hour electrocardiographic monitoring was more accurate than either technique alone or than clinical information collected during admission in predicting these events. The combination identified a high risk group of 13 (8%) patients, with an arrhythmic event rate of 62% and a low risk group with an event rate of 2%. The combination of high gain, signal averaged electrocardiography and 24 hour electrocardiographic monitoring in the first week after myocardial infarction provides a rapid, cheap, and non-invasive bedside method for the prediction of arrhythmias. PMID:3179133

  2. Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment

    PubMed Central

    De Cooman, Thomas; Gu, Ying; Cleeren, Evy; Claes, Kasper; Van Paesschen, Wim; Van Huffel, Sabine; Hunyadi, Borbála

    2017-01-01

    Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG. PMID:29027928

  3. Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment.

    PubMed

    Vandecasteele, Kaat; De Cooman, Thomas; Gu, Ying; Cleeren, Evy; Claes, Kasper; Paesschen, Wim Van; Huffel, Sabine Van; Hunyadi, Borbála

    2017-10-13

    Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG.

  4. Design of electrocardiography measurement system with an algorithm to remove noise

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeokjun; Oh, Sechang; Kumar, Prashanth; Varadan, Vijay K.

    2011-04-01

    Electrocardiography (ECG) is an important diagnostic tool that can provide vital information about diseases that may not be detectable with other biological signals like, SpO2(Oxygen Saturation), pulse rate, respiration, and blood pressure. For this reason, EKG measurement is mandatory for accurate diagnosis. Recent development in information technology has facilitated remote monitoring systems which can check patient's current status. Moreover, remote monitoring systems can obviate the need for patients to go to hospitals periodically. Such representative wireless communication system is Zigbee sensor network because Zigbee sensor network provides low power consumption and multi-device connection. When we measure EKG signal, another important factor that we should consider is about unexpected signals mixed to EKG signal. The unexpected signals give a severe impact in distorting original EKG signal. There are three kinds of types in noise elements such as muscle noise, movement noise, and respiration noise. This paper describes the design method for EKG measurement system with Zigbee sensor network and proposes an algorithm to remove noises from measured ECG signal.

  5. Association between activities of SOD, MDA and Na+-K+-ATPase in peripheral blood of patients with acute myocardial infarction and the complication of varying degrees of arrhythmia.

    PubMed

    Yin, Yu; Han, Wei; Cao, Ying

    2018-04-24

    To investigate the changes of ambulatory electrocardiography and peripheral blood SOD, MDA and Na+-K+-ATP enzymes in patients of acute myocardial infarction (AMI) complicated with arrhythmia. From January 2012 to March 2015, 135 cases AMI complicated with arrhythmia in our hospital were divided into 2 groups: 70 cases in the AMI uncomplicated with arrhythmia and 65 cases in the AMI complicated with arrhythmia. 62 cases volunteers accepted physical examination in our hospital in the same period were collected as the control group. 24 hour-electrocardiogram detected by ambulatory electrocardiogram (AECG), SOD and MDA in peripheral blood detected by diagnostic reagent kit and Na+-K+-ATP enzymes in peripheral blood detected by malachite green Kit Method phosphate determination method were collected. ROC curve was used to evaluate the prognostic value of SOD, MDA and Na+-K+-ATP enzymes in AMI patients. Compared with the control group, the patients had unusual ambulatory electrocardiography had increased (P <0.05), peripheral blood SOD and Na+-K+-ATP enzymes had decreased, peripheral blood MDA had increased in 2 AMI groups (P <0.05). Compared with AMI uncomplicated with arrhythmia group, the patients had unusual ambulatory electrocardiography had increased (P <0.05), peripheral blood SOD and Na+-K+-ATP enzymes had decreased, peripheral blood MDA had increased in AMI complicated with arrhythmia group (P <0.05). Among 135 cases AMI patients, 120 (88.9%) survived and 15 (11.1%) died, of whom 11 cases were AMI complicated with arrhythmia group, 4 cases were AMI uncomplicated with arrhythmia group. Compared with the AMI uncomplicated with arrhythmia group, the dead patients were more in the AMI complicated with arrhythmia group (c2 = 4.287, P = 0.038). Compared with the survival group, the SOD and Na+-K+-ATP enzymes were significantly lower (P <0.05) and MDA significantly higher (P <0.05) in the death group. The area under the ROC curve of SOD, MDA and Na+-K+-ATP enzymes were 0.958, 0.954 and 0.993 respectively, and the cut-off values were 30.66 ng/ml, 576.70 nmol/ml and 57.42 nmol/mgh, respectively. Ambulatory electrocardiography has a close relationship with the peripheral blood SOD, MDA and Na+-K+-ATP enzymes in AMI patients complicated with arrhythmia, which might predict AMI condition. Copyright © 2018 Hellenic Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  6. Continuous electrocardiogram reveals differenced in the short-term cardiotoxic response of Wistar-Kyoto and spontaneously hypertensive rats to doxorubicin

    EPA Science Inventory

    Electrocardiography (ECG) is one of the standard technologies used to monitor and assess cardiac function, and provide insight into the mechanisms driving myocardial pathology. Increased understanding of the effects of cardiovascular disease on rat ECG may help make ECG assessmen...

  7. Exploring Individual Differences in Workload Assessment

    DTIC Science & Technology

    2014-12-26

    83 Question 3: Do the physiological measures: blinks, saccades, HR, HRV , correlate with the objective workload profile for all...Electrooculography (EOG) signals, and heart rate (HR) and heart rate variability ( HRV ) as determined from Electrocardiography (ECG...3) Do the physiological measures blinks, saccades, HR, and HRV , correlate with the objective workload profile for all divergent participants and

  8. Interactive Videoconference Supported Teaching in Undergraduate Nursing: A Case Study for ECG

    ERIC Educational Resources Information Center

    Celikkan, Ufuk; Senuzun, Fisun; Sari, Dilek; Sahin, Yasar Guneri

    2013-01-01

    This paper describes how interactive videoconference can benefit the Electrocardiography (ECG) skills of undergraduate nursing students. We have implemented a learning system that interactively transfers the visual and practical aspects of ECG from a nursing skills lab into a classroom where the theoretical part of the course is taught. The…

  9. Clinical Application of Electrocardiography.

    ERIC Educational Resources Information Center

    Brammell, H. L.; Orr, William

    The scalar electrocardiogram (ECG) is one of the most important and commonly used clinical tools in medicine. A detailed description of the recordings of cardiac electrical activity made by the ECG is presented, and the vast numbers of uses made with the data provided by this diagnostic tool are cited. Clinical applications of the ECG are listed.…

  10. Clinical characterization of cardiovascular abnormalities associated with feline mucopolysaccharidosis I and VI.

    PubMed

    Sleeper, M M; Kusiak, C M; Shofer, F S; O'Donnell, P; Bryan, C; Ponder, K P; Haskins, M E

    2008-06-01

    The purpose of this study was to define the cardiovascular abnormalities present in young and adult cats affected with the lysosomal storage diseases mucopolysaccharidosis (MPS) I and MPS VI. Eighteen cats affected with MPS I and 10 cats affected with MPS VI were evaluated by physical examination, electrocardiography and echocardiography. Electrocardiography (ECG) was performed on all MPS I and 9 of the MPS VI cats. Twelve unaffected cats underwent complete examinations for comparison purposes. No cardiovascular abnormalities were noted on physical examination. Measured ECG intervals were normal in affected cats; however, sinus arrhythmia was noted more frequently than in the unaffected cats. Significant echocardiographic abnormalities included aortic valve thickening, regurgitation and aortic root dilation. Significant mitral valve thickening was also noted. The severity of changes increased in older affected cats. As affected animals increased in age, more cardiac abnormalities were found with increasing severity. Significant lesions included the mitral and aortic valves and ascending aorta, but myocardial changes were not recognized. MPS I and MPS VI cats have similar cardiovascular findings to those seen in children and constitute important models for testing new MPS therapies.

  11. A simple device to illustrate the Einthoven triangle

    PubMed Central

    Jin, Benjamin E.; Wulff, Heike; Widdicombe, Jonathan H.; Zheng, Jie; Bers, Donald M.

    2012-01-01

    The Einthoven triangle is central to the field of electrocardiography, but the concept of cardiac vectors is often a difficult notion for students to grasp. To illustrate this principle, we constructed a device that recreates the conditions of an ECG reading using a battery to simulate the electrical vector of the heart and three voltmeters for the main electrocardiographic leads. Requiring minimal construction with low cost, this device provides hands-on practice that enables students to rediscover the principles of the Einthoven triangle, namely, that the direction of the cardiac dipole can be predicted from the deflections in any two leads and that lead I + lead III = lead II independent of the position of heart's electrical vector. We built a total of 6 devices for classes of 30 students and tested them in the first-year Human Physiology course at the University of California-Davis School of Medicine. Combined with traditional demonstrations with ECG machines, this equipment demonstrated its ability to help medical students obtain a solid foundation of the basic principles of electrocardiography. PMID:23209014

  12. Value of Exercise Stress Electrocardiography for Risk Stratification in Patients With Suspected or Known Coronary Artery Disease in the Era of Advanced Imaging Technologies

    PubMed Central

    Bourque, Jamieson M.; Beller, George A.

    2015-01-01

    Exercise stress electrocardiography (ExECG) is underutilized as the initial test modality in patients with interpretable electrocardiograms able to exercise. Although, stress myocardial imaging techniques provide valuable diagnostic and prognostic information, variables derived from ExECG can yield substantial data for risk stratification, either supplementary to imaging variables, or without concurrent imaging. In addition to exercise-induced ischemic ST depression, such markers as ST segment elevation in lead AVR, abnormal heart rate recovery post-exercise, failure to achieve target heart rate, and poor exercise capacity improve risk stratification of ExECG. For example, patients achieving ≥10 METS on ExECG have a very low prevalence of inducible ischemia and an excellent prognosis. In contrast, cardiac imaging techniques add diagnostic and prognostic value in higher risk populations (e.g. poor functional capacity, diabetes, chronic kidney disease). Optimal test selection for symptomatic patients with suspected coronary artery disease requires a patient-centered approach factoring in the risk/benefit ratio and cost-effectiveness. PMID:26563861

  13. Which test for CAD should be used in patients with left bundle branch block?

    PubMed

    Xu, Bo; Cremer, Paul; Jaber, Wael; Moir, Stuart; Harb, Serge C; Rodriguez, L Leonardo

    2018-03-01

    Exercise stress electrocardiography is unreliable as a test for obstructive coronary artery disease (CAD) if the patient has left bundle branch block. The authors provide an algorithm for using alternative tests: exercise stress echocardiography, dobutamine echocardiography, computed tomographic (CT) angiography, and nuclear myocardial perfusion imaging. Copyright © 2018 Cleveland Clinic.

  14. The Evolutionary Development of Echocardiography

    PubMed Central

    Maleki, Majid; Esmaeilzadeh, Maryam

    2012-01-01

    Echocardiography is a non-invasive diagnostic technique which provides information on cardiac morphology, function, and hemodynamics. It is the most frequently used cardiovascular diagnostic test only after electrocardiography. In less than five decades, the evolution in this technique has made it the basic part of cardiovascular medicine. Herein, the evolution of various forms of echocardiography is briefly described. PMID:23390327

  15. Prenatal diagnosis of long QT syndrome with the superior vena cava-aorta Doppler approach.

    PubMed

    Chabaneix, Julie; Andelfinger, Gregor; Fournier, Anne; Fouron, Jean-Claude; Raboisson, Marie-Josée

    2012-10-01

    We describe a fetus at 36 weeks with long QT syndrome presenting with variable types of atrioventricular blocks, ventricular premature beats, and torsades de pointes. All these diagnoses were made with the superior vena cava-aorta Doppler approach and confirmed with postnatal electrocardiography. Copyright © 2012 Mosby, Inc. All rights reserved.

  16. The United States Army Medical Department Journal. October - December 2012

    DTIC Science & Technology

    2012-12-01

    assess effect on weight change following injury. Nutritional programs aimed at smaller meal consumption , inclusion of breakfast, making healthier...electrocardiography, blood pres- sure, oxygen saturation, end-tidal carbon dioxide, and rectal temperatures were continuously monitored for the...blood pressure, oxygen saturation, end-tidal carbon dioxide, and rectal temperatures . Body temperature was maintained greater than 36.0°C. When

  17. An unusual case of infective endocarditis presenting as acute myocardial infarction.

    PubMed

    Chen, Zhong; Ng, Francesca; Nageh, Thuraia

    2007-06-01

    A 39-year-old Zimbabwean man presented with a 1 week history of fever, general malaise and acute-onset chest pain. He had a urethral stricture, which had been managed with an indwelling supra-pubic catheter. The electrocardiography on admission showed inferior ST-T segments elevation. His chest pain and electrocardiography changes resolved subsequent to thrombolysis, and he remained haemodynamically stable. The 12-h troponin I was increased at 10.5 microg/l (NR <0.04 microg/l). Echocardiography confirmed severe mitral regurgitation and a flail anterior mitral valve leaflet with an independently oscillating mobile vegetation. Enterococci faecalis were grown on blood cultures. A diagnosis of enterococci infective endocarditis with concomitant acute myocardial infarction due to possible septic emboli was made. Despite the successful outcome from thrombolysis in the setting of acute myocardial infarction with infective endocarditis, the case highlights the current lack of definitive data on the optimal acute management of such an unusual clinical scenario. Although there is serious concern that thrombolytic treatment for myocardial infarction in the setting of infective endocarditis may be associated with higher risk of cerebral haemorrhage, there is little documented evidence supporting the safety of primary percutaneous coronary intervention with these patients.

  18. Spontaneous, resolving S1Q3T3 in pulmonary embolism: A case report and literature review on prognostic value of electrocardiography score for pulmonary embolism.

    PubMed

    Cygan, Lukasz D; Weizberg, Moshe; Hahn, Barry

    2016-09-01

    Electrocardiography findings in patients with pulmonary embolism have been investigated since 1935. As medicine has evolved, more effective modalities have surpassed the electrocardiogram in diagnostic utility. Despite the advent of these other modalities, the diagnosis of pulmonary embolism remains elusive and the prognosis is variable amongst each clinical presentation of its pathology. After presenting a case of a resolving S1Q3T3 in subsequent electrocardiogram findings of a patient with pulmonary embolism, this literature review will provide information on a 21-point electrocardiogram scoring system that helps the emergency physician stratify the risk of a patient with an acute presentation of pulmonary embolism. Why should emergency care staff be aware of this? Given the time-sensitive nature of diagnosis and appropriate treatment, Electrocardiogram continues to be a tool in the assessment of patients with a clinical suspicion of pulmonary embolism. Based on the information provided, 21-point electrocardiogram score has been shown to have strong usefulness in assessing prognosis of patients presenting with acute pulmonary embolism. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health

    PubMed Central

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lee, Ming-Yih

    2017-01-01

    Use of information and communication technology such as smart phone, smart watch, smart glass and portable health monitoring devices for healthcare services has made Mobile Health (mHealth) an emerging research area. Coronary Heart Disease (CHD) is considered as a leading cause of death world wide and an increasing number of people die prematurely due to CHD. Under such circumstances, there is a growing demand for a reliable cardiac monitoring system to catch the intermittent abnormalities and detect critical cardiac behaviors which lead to sudden death. Use of mobile devices to collect Electrocardiography (ECG), Seismocardiography (SCG) data and efficient analysis of those data can monitor a patient’s cardiac activities for early warning. This paper presents a novel cardiac data acquisition method and combined analysis of Electrocardiography (ECG) and multi channel Seismocardiography (SCG) data. An early warning system is implemented to monitor the cardiac activities of a person and accuracy assessment of the early warning system is conducted for the ECG data only. The assessment shows 88% accuracy and effectiveness of our proposed analysis, which implies the viability and applicability of the proposed early warning system. PMID:28353681

  20. Combined Electrocardiography- and Respiratory-Triggered CT of the Lung to Reduce Respiratory Misregistration Artifacts between Imaging Slabs in Free-Breathing Children: Initial Experience.

    PubMed

    Goo, Hyun Woo; Allmendinger, Thomas

    2017-01-01

    Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months-8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children.

  1. Polyphonic sonification of electrocardiography signals for diagnosis of cardiac pathologies

    NASA Astrophysics Data System (ADS)

    Kather, Jakob Nikolas; Hermann, Thomas; Bukschat, Yannick; Kramer, Tilmann; Schad, Lothar R.; Zöllner, Frank Gerrit

    2017-03-01

    Electrocardiography (ECG) data are multidimensional temporal data with ubiquitous applications in the clinic. Conventionally, these data are presented visually. It is presently unclear to what degree data sonification (auditory display), can enable the detection of clinically relevant cardiac pathologies in ECG data. In this study, we introduce a method for polyphonic sonification of ECG data, whereby different ECG channels are simultaneously represented by sound of different pitch. We retrospectively applied this method to 12 samples from a publicly available ECG database. We and colleagues from our professional environment then analyzed these data in a blinded way. Based on these analyses, we found that the sonification technique can be intuitively understood after a short training session. On average, the correct classification rate for observers trained in cardiology was 78%, compared to 68% and 50% for observers not trained in cardiology or not trained in medicine at all, respectively. These values compare to an expected random guessing performance of 25%. Strikingly, 27% of all observers had a classification accuracy over 90%, indicating that sonification can be very successfully used by talented individuals. These findings can serve as a baseline for potential clinical applications of ECG sonification.

  2. Computational Electrocardiography: Revisiting Holter ECG Monitoring.

    PubMed

    Deserno, Thomas M; Marx, Nikolaus

    2016-08-05

    Since 1942, when Goldberger introduced the 12-lead electrocardiography (ECG), this diagnostic method has not been changed. After 70 years of technologic developments, we revisit Holter ECG from recording to understanding. A fundamental change is fore-seen towards "computational ECG" (CECG), where continuous monitoring is producing big data volumes that are impossible to be inspected conventionally but require efficient computational methods. We draw parallels between CECG and computational biology, in particular with respect to computed tomography, computed radiology, and computed photography. From that, we identify technology and methodology needed for CECG. Real-time transfer of raw data into meaningful parameters that are tracked over time will allow prediction of serious events, such as sudden cardiac death. Evolved from Holter's technology, portable smartphones with Bluetooth-connected textile-embedded sensors will capture noisy raw data (recording), process meaningful parameters over time (analysis), and transfer them to cloud services for sharing (handling), predicting serious events, and alarming (understanding). To make this happen, the following fields need more research: i) signal processing, ii) cycle decomposition; iii) cycle normalization, iv) cycle modeling, v) clinical parameter computation, vi) physiological modeling, and vii) event prediction. We shall start immediately developing methodology for CECG analysis and understanding.

  3. A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health.

    PubMed

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lee, Ming-Yih

    2017-03-29

    Use of information and communication technology such as smart phone, smart watch, smart glass and portable health monitoring devices for healthcare services has made Mobile Health (mHealth) an emerging research area. Coronary Heart Disease (CHD) is considered as a leading cause of death world wide and an increasing number of people die prematurely due to CHD. Under such circumstances, there is a growing demand for a reliable cardiac monitoring system to catch the intermittent abnormalities and detect critical cardiac behaviors which lead to sudden death. Use of mobile devices to collect Electrocardiography (ECG), Seismocardiography (SCG) data and efficient analysis of those data can monitor a patient's cardiac activities for early warning. This paper presents a novel cardiac data acquisition method and combined analysis of Electrocardiography (ECG) and multi channel Seismocardiography (SCG) data. An early warning system is implemented to monitor the cardiac activities of a person and accuracy assessment of the early warning system is conducted for the ECG data only. The assessment shows 88% accuracy and effectiveness of our proposed analysis, which implies the viability and applicability of the proposed early warning system.

  4. Twenty-four-hour ambulatory electrocardiography characterization of heart rhythm in Vipera berus-envenomed dogs.

    PubMed

    Vestberg, Anna Rave; Tidholm, Anna; Ljungvall, Ingrid

    2017-05-03

    Vipera berus has a worldwide distribution and causes high morbidity in dogs annually. A complication to envenomation may be cardiac arrhythmias. The purpose of this study was to investigate the prevalence, types, and timing of arrhythmias, using 24-h ambulatory electrocardiography (24-AECG), in dogs bitten by V. berus in the first 24-32 h after envenomation. In addition, this study aimed to investigate if there were differences in selected clinical and hematological- and biochemical variables (including cardiac troponin I) at admission between V. berus-envenomed dogs with and without detected pathologic arrhythmias. Seventeen prospectively recruited client-owned dogs acutely envenomed by V. berus, were therefore examined clinically and echocardiographically, sampled for blood, hospitalized, and monitored by 24-AECG. Clinically significant pathologic arrhythmias in this study were of ventricular origin, such as frequent single ventricular premature contractions (VPCs) and couplets of VPCs, episodes of ventricular tachycardia and idioventricular rhythm, and "R-on-T phenomenon". Variations of these arrhythmias were detected by 24-AECG in eight (47%) of included dogs. No arrhythmias were detected by cardiac auscultation. Twenty-four hours following envenomation, four out of eight dogs experienced decreases (all P < 0.039), and three out of eight dogs experienced increases (all P < 0.034), in arrhythmic episodes. All four dogs bitten on a limb developed pathologic arrhythmias. Otherwise, no significant differences in clinical, hematological or biochemical variables were seen between dogs with pathologic arrhythmias and those without. Forty-seven percent of dogs bitten by V. berus included in this study experienced pathologic arrhythmias of abnormal ventricular depolarization. During the first 24-32 h from the snakebite, some dogs experienced a decrease in arrhythmic episodes and others an increase in arrhythmic episodes. These findings indicate a potential value of repeated or prolonged electrocardiography monitoring of envenomed dogs for identification of which dogs that might benefit the most from prolonged hospitalization for optimal monitoring and treatment of cardiac abnormalities. In the present study, dogs that developed arrhythmias could not be differentiated from dogs that did not based on clinical findings or hematological or biochemical variables obtained at admission.

  5. Dual-Gated Motion-Frozen Cardiac PET with Flurpiridaz F 18.

    PubMed

    Slomka, Piotr J; Rubeaux, Mathieu; Le Meunier, Ludovic; Dey, Damini; Lazewatsky, Joel L; Pan, Tinsu; Dweck, Marc R; Newby, David E; Germano, Guido; Berman, Daniel S

    2015-12-01

    A novel PET radiotracer, Flurpiridaz F 18, has undergone phase II clinical trial evaluation as a high-resolution PET cardiac perfusion imaging agent. In a subgroup of patients imaged with this agent, we assessed the feasibility and benefit of simultaneous correction of respiratory and cardiac motion. In 16 patients, PET imaging was performed on a 4-ring scanner in dual cardiac and respiratory gating mode. Four sets of data were reconstructed with high-definition reconstruction (HD•PET): ungated and 8-bin electrocardiography-gated images using 5-min acquisition, optimal respiratory gating (ORG)-as developed for oncologic imaging-using a narrow range of breathing amplitude around end-expiration level with 35% of the counts in a 7-min acquisition, and 4-bin respiration-gated and 8-bin electrocardiography-gated images (32 bins in total) using the 7-min acquisition (dual-gating, using all data). Motion-frozen (MF) registration algorithms were applied to electrocardiography-gated and dual-gated data, creating cardiac-MF and dual-MF images. We computed wall thickness, wall/cavity contrast, and contrast-to-noise ratio for standard, ORG, cardiac-MF, and dual-MF images to assess image quality. The wall/cavity contrast was similar for ungated (9.3 ± 2.9) and ORG (9.5 ± 3.2) images and improved for cardiac-MF (10.8 ± 3.6) and dual-MF images (14.8 ± 8.0) (P < 0.05). The contrast-to-noise ratio was 22.2 ± 9.1 with ungated, 24.7 ± 12.2 with ORG, 35.5 ± 12.8 with cardiac-MF, and 42.1 ± 13.2 with dual-MF images (all P < 0.05). The wall thickness was significantly decreased (P < 0.05) with dual-MF (11.6 ± 1.9 mm) compared with ungated (13.9 ± 2.8 mm), ORG (13.1 ± 2.9 mm), and cardiac-MF images (12.1 ± 2.7 mm). Dual (respiratory/cardiac)-gated perfusion imaging with Flurpiridaz F 18 is feasible and improves image resolution, contrast, and contrast-to-noise ratio when MF registration methods are applied. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

    PubMed Central

    Jezewski, Janusz; Wrobel, Janusz; Matonia, Adam; Horoba, Krzysztof; Martinek, Radek; Kupka, Tomasz; Jezewski, Michal

    2017-01-01

    Great expectations are connected with application of indirect fetal electrocardiography (FECG), especially for home telemonitoring of pregnancy. Evaluation of fetal heart rate (FHR) variability, when determined from FECG, uses the same criteria as for FHR signal acquired classically—through ultrasound Doppler method (US). Therefore, the equivalence of those two methods has to be confirmed, both in terms of recognizing classical FHR patterns: baseline, accelerations/decelerations (A/D), long-term variability (LTV), as well as evaluating the FHR variability with beat-to-beat accuracy—short-term variability (STV). The research material consisted of recordings collected from 60 patients in physiological and complicated pregnancy. The FHR signals of at least 30 min duration were acquired dually, using two systems for fetal and maternal monitoring, based on US and FECG methods. Recordings were retrospectively divided into normal (41) and abnormal (19) fetal outcome. The complex process of data synchronization and validation was performed. Obtained low level of the signal loss (4.5% for US and 1.8% for FECG method) enabled to perform both direct comparison of FHR signals, as well as indirect one—by using clinically relevant parameters. Direct comparison showed that there is no measurement bias between the acquisition methods, whereas the mean absolute difference, important for both visual and computer-aided signal analysis, was equal to 1.2 bpm. Such low differences do not affect the visual assessment of the FHR signal. However, in the indirect comparison the inconsistencies of several percent were noted. This mainly affects the acceleration (7.8%) and particularly deceleration (54%) patterns. In the signals acquired using the electrocardiography the obtained STV and LTV indices have shown significant overestimation by 10 and 50% respectively. It also turned out, that ability of clinical parameters to distinguish between normal and abnormal groups do not depend on the acquisition method. The obtained results prove that the abdominal FECG, considered as an alternative to the ultrasound approach, does not change the interpretation of the FHR signal, which was confirmed during both visual assessment and automated analysis. PMID:28559852

  7. Physiologic Status Monitoring via the Gastrointestinal Tract

    DTIC Science & Technology

    2015-11-18

    1763-1773. 7. Deswysen AC, Zimerson E, Goossens A, Bruze M, Baeck M (2013) Allergic contact dermatitis caused by self-adhesive electrocardiography...electrodes in an infant. Contact dermatitis 69: 379-381. 8. Rafiei H, Amiri M, Moghaddasi J (2013) Skin irritation because of electrocardiograph lead...microphone, we measured acoustic data along the GI tract from the mouth to the colon. We evaluated the impact device contact with GI tissue and

  8. Physiologic Status Monitoring via the Gastrointestinal Tract

    DTIC Science & Technology

    2015-11-18

    7. Deswysen AC, Zimerson E, Goossens A, Bruze M, Baeck M (2013) Allergic contact dermatitis caused by self-adhesive electrocardiography electrodes...in an infant. Contact dermatitis 69: 379-381. 8. Rafiei H, Amiri M, Moghaddasi J (2013) Skin irritation because of electrocardiograph lead in...microphone, we measured acoustic data along the GI tract from the mouth to the colon. We evaluated the impact device contact with GI tissue and previously

  9. Physiologic Status Monitoring via the Gastrointestinal Tract

    DTIC Science & Technology

    2016-02-25

    7. Deswysen AC, Zimerson E, Goossens A, Bruze M, Baeck M (2013) Allergic contact dermatitis caused by self-adhesive electrocardiography electrodes...in an infant. Contact dermatitis 69: 379-381. 8. Rafiei H, Amiri M, Moghaddasi J (2013) Skin irritation because of electrocardiograph lead in...we measured acoustic data along the GI tract from the mouth to the colon. We evaluated the impact device contact with GI tissue and previously

  10. A systematic review of prenatal screening for congenital heart disease by fetal electrocardiography.

    PubMed

    Verdurmen, Kim M J; Eijsvoogel, Noortje B; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; van Laar, Judith O E H; Oei, S Guid

    2016-11-01

    Congenital heart disease (CHD) is the most common severe congenital anomaly worldwide. Diagnosis early in pregnancy is important, but the detection rate by two-dimensional ultrasonography is only 65%-81%. To evaluate existing data on CHD and noninvasive abdominal fetal electrocardiography (ECG). A systematic review was performed through a search of the Cochrane Library, PubMed, and Embase for studies published up to April 2016 using the terms "congenital heart disease," "fetal electrocardiogram," and other similar keywords. Primary articles that described changes in fetal ECG among fetuses with CHD published in English were included. Outcomes of interest were changes in fetal ECG parameters observed for fetuses with congenital heart disease. Findings were reported descriptively. Only five studies described changes observed in the fetal electrocardiogram for fetuses with CHD, including heart rate, heart rate variability, and PR, QRS, and QT intervals. Fetal ECG reflects the intimate relationship between the cardiac nerve conduction system and the structural morphology of the heart. It seems particularly helpful in detecting the electrophysiological effects of cardiac anatomic defects (e.g. hypotrophy, hypertrophy, and conduction interruption). Fetal ECG might be a promising clinical tool to complement ultrasonography in the screening program for CHD. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  11. A brief review: history to understand fundamentals of electrocardiography

    PubMed Central

    AlGhatrif, Majd; Lindsay, Joseph

    2012-01-01

    The last decade of the 19th century witnessed the rise of a new era in which physicians used technology along with classical history taking and physical examination for the diagnosis of heart disease. The introduction of chest x-rays and the electrocardiograph (electrocardiogram) provided objective information about the structure and function of the heart. In the first half of the 20th century, a number of innovative individuals set in motion a fascinating sequence of discoveries and inventions that led to the 12-lead electrocardiogram, as we know it now. Electrocardiography, nowadays, is an essential part of the initial evaluation for patients presenting with cardiac complaints. As a first line diagnostic tool, health care providers at different levels of training and expertise frequently find it imperative to interpret electrocardiograms. It is likely that an understanding of the electrical basis of electrocardiograms would reduce the likelihood of error. An understanding of the disorders behind electrocardiographic phenomena could reduce the need for memorizing what may seem to be an endless list of patterns. In this article, we will review the important steps in the evolution of electrocardiogram. As is the case in most human endeavors, an understanding of history enables one to deal effectively with the present. PMID:23882360

  12. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    PubMed

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Combined Electrocardiography- and Respiratory-Triggered CT of the Lung to Reduce Respiratory Misregistration Artifacts between Imaging Slabs in Free-Breathing Children: Initial Experience

    PubMed Central

    Allmendinger, Thomas

    2017-01-01

    Objective Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. Materials and Methods In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Results Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Conclusion Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children. PMID:28860904

  14. An Approach to Noise Reduction in Human Skin Admittance Measurements

    DTIC Science & Technology

    2001-10-25

    1966, 4, 439-449. [ 4] D. H. Gordon, "Triboelectric interference in the ECG", IEEE Trans., 1975, BME -22, 252-255. [ 5] J. C. Huhta and J. G...Webster, ඄-Hz interference in electrocardiography", IEEE Trans., 1973, BME -20, 91-101. [ 6] S. Grimnes, "Electrovibration, cutaneous sensation of...this period he has published two textbooks about UNIX and Shell Programming, and concentrated at computer simulation and digital signal processing

  15. [A telemedicine electrocardiography system based on the component-architecture soft].

    PubMed

    Potapov, I V; Selishchev, S V

    2004-01-01

    The paper deals with a universal component-oriented architecture for creating the telemedicine applications. The worked-out system ensures the ECG reading, pressure measurements and pulsometry. The system design comprises a central database server and a client telemedicine module. Data can be transmitted via different interfaces--from an ordinary local network to digital satellite phones. The data protection is guaranteed by microchip charts that were used to realize the authentication 3DES algorithm.

  16. Intracardiac electrocardiography via a "saline-filled central venous catheter electrocardiographic lead": a historical perspective.

    PubMed

    Madias, John E

    2004-04-01

    The author describes his experience with a "saline-filled central venous catheter electrocardiographic lead" for the recording of intracardiac electrocardiograms provides a brief description of the methodology, refers to this modality's clinical usefulness, furnishes 2 examples illustrating the contribution of the method to clinical diagnosis, and outlines his literature search to find the discoverer/originator of the employment of a saline-filled intracardiac catheter as an electrocardiogram recording lead.

  17. Dilated cardiomyopathy and sinoatrial dysfunction in an Estrela mountain dog.

    PubMed

    Lobo, Luis; Pinheiro-Vieira, António; Gomes, João L; Canada, Nuno; Ribeiro, Lenio; Costa, Paulo D; Oliveira, Pedro; Bussadori, Claudio

    2012-01-01

    A 1 yr old male Estrela mountain dog was evaluated as a part of a screening program for dilated cardiomyopathy. The dog came from a family with a history of dilated cardiomyopathy but was asymptomatic. Occult dilated cardiomyopathy and sino-atrial dysfunction were diagnosed based on echocardiography and electrocardiography. These two disorders may be associated given that related dogs have been diagnosed with the same disorders. The dog has remained asymptomatic for 4 years following initial evaluation.

  18. Using a Cloud Computing System to Reduce Door-to-Balloon Time in Acute ST-Elevation Myocardial Infarction Patients Transferred for Percutaneous Coronary Intervention.

    PubMed

    Ho, Chi-Kung; Chen, Fu-Cheng; Chen, Yung-Lung; Wang, Hui-Ting; Lee, Chien-Ho; Chung, Wen-Jung; Lin, Cheng-Jui; Hsueh, Shu-Kai; Hung, Shin-Chiang; Wu, Kuan-Han; Liu, Chu-Feng; Kung, Chia-Te; Cheng, Cheng-I

    2017-01-01

    This study evaluated the impact on clinical outcomes using a cloud computing system to reduce percutaneous coronary intervention hospital door-to-balloon (DTB) time for ST segment elevation myocardial infarction (STEMI). A total of 369 patients before and after implementation of the transfer protocol were enrolled. Of these patients, 262 were transferred through protocol while the other 107 patients were transferred through the traditional referral process. There were no significant differences in DTB time, pain to door of STEMI receiving center arrival time, and pain to balloon time between the two groups. Pain to electrocardiography time in patients with Killip I/II and catheterization laboratory to balloon time in patients with Killip III/IV were significantly reduced in transferred through protocol group compared to in traditional referral process group (both p < 0.05). There were also no remarkable differences in the complication rate and 30-day mortality between two groups. The multivariate analysis revealed that the independent predictors of 30-day mortality were elderly patients, advanced Killip score, and higher level of troponin-I. This study showed that patients transferred through our present protocol could reduce pain to electrocardiography and catheterization laboratory to balloon time in Killip I/II and III/IV patients separately. However, this study showed that using a cloud computing system in our present protocol did not reduce DTB time.

  19. The non-contact measure of the heart rate variability by laser Doppler vibrometry: comparison with electrocardiography

    NASA Astrophysics Data System (ADS)

    Cosoli, G.; Casacanditella, L.; Tomasini, E. P.; Scalise, L.

    2016-06-01

    The assessment of the heart rate variability (HRV) is of utmost importance, being one of the most promising markers of the activity of the autonomic nervous system and associated to cardiovascular mortality. Different signals can be used to perform HRV, primarily electrocardiography (ECG), photoplethysmography (PPG), phonocardiography (PCG) or vibrocardiography (VCG), since the fundamental aspect is the individuation of a periodic feature strictly correlated with cardiac activity (i.e. R-peak in ECG or the first sound in PCG). In this work, the authors demonstrate that the VCG performances in HRV analysis are sufficiently accurate if compared to the ones measured by ECG (i.e. standard methodology); moreover, the authors want to prove the feasibility of such measurement in correspondence of different measurement points (i.e. carotid artery—which is the typical VCG measurement point—and the radial artery on the wrist)1. Results show that VCG has a mean deviation of  <1 bpm with respect to ECG in heart rate (HR) measurement; carotid artery is the most accurate site for the assessment, but also the radial artery is a valid site, even if with a reduced SNR. With regards to HRV parameters, the mean percentage deviation is  <10% in correspondence of carotid artery, and  ≈16% for the radial artery. So, VCG allows for non-contact monitoring of the cardiac activity.

  20. Effect of intravenous amiodarone on QT and T peak-T end dispersions in patients with nonischemic heart failure treated with cardiac resynchronization-defibrillator therapy and electrical storm.

    PubMed

    Ogiso, Masataka; Suzuki, Atsushi; Shiga, Tsuyoshi; Nakai, Kenji; Shoda, Morio; Hagiwara, Nobuhisa

    2015-02-01

    The effect of intravenous amiodarone on spatial and transmural dispersion of ventricular repolarization in patients receiving cardiac resynchronization therapy (CRT) remains unclear. We studied 14 patients with nonischemic heart failure who received CRT with a defibrillator, experienced electrical storm and were treated with intravenous amiodarone. Each patient underwent 12-lead electrocardiography (ECG) and 187-channel repolarization interval-difference mapping electrocardiography (187-ch RIDM-ECG) before and during the intravenous administration of amiodarone infusion. A recurrence of ventricular tachyarrhythmia was observed in 2 patients during the early period of intravenous amiodarone therapy. Intravenous amiodarone increased the corrected QT interval (from 470±52 ms to 508±55 ms, P=0.003), but it significantly decreased the QT dispersion (from 107±35 ms to 49±27 ms, P=0.001), T peak-T end (Tp-e) dispersion (from 86±17 ms to 28±28 ms, P=0.001), and maximum inter-lead difference between corrected Tp-e intervals as measured by using the 187-ch RIDM-ECG (from 83±13 ms to 50±19 ms, P=0.001). Intravenous amiodarone suppressed the electrical storm and decreased the QT and Tp-e dispersions in patients treated by using CRT with a defibrillator.

  1. Prevalence and clinical implications of improper filter settings in routine electrocardiography.

    PubMed

    Kligfield, Paul; Okin, Peter M

    2007-03-01

    High- and low-filter bandwidth governs the fidelity of electrocardiographic waveforms, including the durations used in established criteria for infarction, the amplitudes used for the diagnosis of ventricular hypertrophy, and the accuracy of the magnitudes of ST-segment elevation and depression. Electrocardiographs allow users to reset high- and low-filter settings for special electrocardiographic applications, but these may be used inappropriately. To examine the prevalence of standard and nonstandard electrocardiographic filtering at 1 general medical community, 256 consecutive outpatient electrocardiograms (ECGs) submitted in advance of ambulatory or same-day admission surgery during a 3-week period were examined. ECGs were considered to meet standards for low-frequency cutoff when equal to 0.05 Hz and to meet standards for high-frequency cutoff when equal to 100 Hz, according to American Heart Association recommendations established in 1975. Only 25% of ECGs (65 of 256) conformed to recommended standards; 75% of ECGs (191 of 254) did not. The most prevalent deviation from standard was reduced high-frequency cutoff, which was present in 96% of tracings with nonstandard bandwidth (most commonly 40 Hz). Increased low-frequency cutoff was present in 62% of ECGs in which it was documented. In conclusion, improper electrocardiographic filtering, with potentially adverse clinical consequences, is highly prevalent at 1 large general medical community and is likely a generalized problem. This problem should be resolvable by targeted educational efforts to reinforce technical standards in electrocardiography.

  2. Optimisation of Embryonic and Larval ECG Measurement in Zebrafish for Quantifying the Effect of QT Prolonging Drugs

    PubMed Central

    Dhillon, Sundeep Singh; Dóró, Éva; Magyary, István; Egginton, Stuart; Sík, Attila; Müller, Ferenc

    2013-01-01

    Effective chemical compound toxicity screening is of paramount importance for safe cardiac drug development. Using mammals in preliminary screening for detection of cardiac dysfunction by electrocardiography (ECG) is costly and requires a large number of animals. Alternatively, zebrafish embryos can be used as the ECG waveform is similar to mammals, a minimal amount of chemical is necessary for drug testing, while embryos are abundant, inexpensive and represent replacement in animal research with reduced bioethical concerns. We demonstrate here the utility of pre-feeding stage zebrafish larvae in detection of cardiac dysfunction by electrocardiography. We have optimised an ECG recording system by addressing key parameters such as the form of immobilization, recording temperature, electrode positioning and developmental age. Furthermore, analysis of 3 days post fertilization (dpf) zebrafish embryos treated with known QT prolonging drugs such as terfenadine, verapamil and haloperidol led to reproducible detection of QT prolongation as previously shown for adult zebrafish. In addition, calculation of Z-factor scores revealed that the assay was sensitive and specific enough to detect large drug-induced changes in QTc intervals. Thus, the ECG recording system is a useful drug-screening tool to detect alteration to cardiac cycle components and secondary effects such as heart block and arrhythmias in zebrafish larvae before free feeding stage, and thus provides a suitable replacement for mammalian experimentation. PMID:23579446

  3. Hypo- and Hyperglycemic Alarms

    PubMed Central

    Howsmon, Daniel; Bequette, B. Wayne

    2015-01-01

    Soon after the discovery that insulin regulates blood glucose by Banting and Best in 1922, the symptoms and risks associated with hypoglycemia became widely recognized. This article reviews devices to warn individuals of impending hypo- and hyperglycemia; biosignals used by these devices include electroencephalography, electrocardiography, skin galvanic resistance, diabetes alert dogs, and continuous glucose monitors (CGMs). While systems based on other technology are increasing in performance and decreasing in size, CGM technology remains the best method for both reactive and predictive alarming of hypo- or hyperglycemia. PMID:25931581

  4. Clinical, Electrocardiographic, and Echocardiographic Parameter Combination Predicts the Onset of Atrial Fibrillation.

    PubMed

    Soeki, Takeshi; Matsuura, Tomomi; Tobiume, Takeshi; Bando, Sachiko; Matsumoto, Kazuhisa; Nagano, Hiromi; Uematsu, Etsuko; Kusunose, Kenya; Ise, Takayuki; Yamaguchi, Koji; Yagi, Shusuke; Fukuda, Daiju; Yamada, Hirotsugu; Wakatsuki, Tetsuzo; Shimabukuro, Michio; Sata, Masataka

    2018-05-30

    The ability to identify risk markers for new-onset atrial fibrillation (AF) is critical to the development of preventive strategies, but it remains unknown whether a combination of clinical, electrocardiographic, and echocardiographic parameters predicts the onset of AF. In the present study, we evaluated the predictive value of a combined score that includes these parameters.Methods and Results:We retrospectively studied 1,040 patients without AF who underwent both echocardiography and 24-h Holter electrocardiography between May 2005 and December 2010. During a median follow-up period of 68.4 months (IQR, 49.9-93.3 months), we investigated the incidence of new-onset AF. Of the 1,040 patients, 103 (9.9%) developed AF. Patients who developed AF were older than patients who did not. Total heart beats, premature atrial contraction (PAC) count, maximum RR interval, and frequency of sinus pause quantified on 24-h electrocardiography were associated with new-onset AF. LA diameter (LAD) on echocardiography was also associated with the development of AF. On multivariate Cox analysis, age ≥58 years, PAC count ≥80 beats/day, maximum RR interval ≥1.64 s, and LAD ≥4.5 cm were independently associated with the development of AF. The incidence rate of new-onset AF significantly increased as the combined score (i.e., the sum of the risk score determined using hazard ratios) increased. A combined score that includes age, PAC count, maximum RR interval, and LAD could help characterize the risk of new-onset AF.

  5. Fresh stillborn and severely asphyxiated neonates share a common hypoxic-ischemic pathway.

    PubMed

    Ersdal, Hege L; Eilevstjønn, Joar; Linde, Jørgen E; Yeconia, Anita; Mduma, Estomih R; Kidanto, Hussein; Perlman, Jeffrey

    2018-05-01

    To characterize, among non-breathing flaccid neonates at delivery, immediate heartrate and responses to ventilation in relation to the clinical diagnosis of fresh stillbirth (FSB) or early neonatal death (END) within 24 hours. The present cross-sectional study included all deliveries at Haydom Hospital in rural Tanzania between July 1, 2013, and July 31, 2016. Ventilation parameters and heartrate were recorded by monitors with ventilation and dry-electrocardiography sensors. Perinatal characteristics were recorded on data forms by trained research assistants. Among 12 789 neonates delivered, 915 were ventilated; among ventilated neonates, there were 53 (6%) FSBs and 64 (7%) ENDs. Electrocardiography was used in 46 FSBs and 55 ENDs, and these neonates were included in a subanalysis. Initial heartrate was detected in 27 (59%) of 46 FSBs and 52 (95%) of 55 ENDs, and was lower in FSBs (52 ± 19 vs 76 ± 37 bpm; P=0.003). More ENDs responded to ventilation (53% vs 9%; P<0.001), with heartrate increasing above 100 bpm. Heartrate at ventilation discontinuation was higher among ENDs (115 ± 49 vs 52 ± 33 bpm; P<0.001). Progression to FSB or END after intrapartum hypoxia/anoxia is probably part of the same circulatory end-process. Distinguishing FSB from severely asphyxiated newborns is clinically difficult and probably influences estimated global perinatal mortality rates. © 2017 International Federation of Gynecology and Obstetrics.

  6. Using a Cloud Computing System to Reduce Door-to-Balloon Time in Acute ST-Elevation Myocardial Infarction Patients Transferred for Percutaneous Coronary Intervention

    PubMed Central

    Ho, Chi-Kung; Wang, Hui-Ting; Lee, Chien-Ho; Chung, Wen-Jung; Lin, Cheng-Jui; Hsueh, Shu-Kai; Hung, Shin-Chiang; Wu, Kuan-Han; Liu, Chu-Feng; Kung, Chia-Te

    2017-01-01

    Background This study evaluated the impact on clinical outcomes using a cloud computing system to reduce percutaneous coronary intervention hospital door-to-balloon (DTB) time for ST segment elevation myocardial infarction (STEMI). Methods A total of 369 patients before and after implementation of the transfer protocol were enrolled. Of these patients, 262 were transferred through protocol while the other 107 patients were transferred through the traditional referral process. Results There were no significant differences in DTB time, pain to door of STEMI receiving center arrival time, and pain to balloon time between the two groups. Pain to electrocardiography time in patients with Killip I/II and catheterization laboratory to balloon time in patients with Killip III/IV were significantly reduced in transferred through protocol group compared to in traditional referral process group (both p < 0.05). There were also no remarkable differences in the complication rate and 30-day mortality between two groups. The multivariate analysis revealed that the independent predictors of 30-day mortality were elderly patients, advanced Killip score, and higher level of troponin-I. Conclusions This study showed that patients transferred through our present protocol could reduce pain to electrocardiography and catheterization laboratory to balloon time in Killip I/II and III/IV patients separately. However, this study showed that using a cloud computing system in our present protocol did not reduce DTB time. PMID:28900621

  7. Exercise thallium-201 tomographic scintigraphy in the diagnosis of coronary artery disease: emphasis on the effect of exercise level.

    PubMed

    Huang, P J; Chieng, P U; Lee, Y T; Chiang, F T; Tseng, Y Z; Liau, C S; Tseng, C D; Su, C T; Lien, W P

    1992-11-01

    Exercise thallium-201 imaging using single-photon emission computed tomography (SPECT) was evaluated in 154 patients with angiographically documented coronary artery disease (CAD) and in 25 normal subjects. Of the 154 patients with CAD, 134 (87%) had abnormal thallium images. By contrast, only 77 (50%) patients had ischemic ST-segment depression (p < 0.001). Among 25 normal subjects, 20 had normal exercise SPECT images. The specificity of exercise SPECT imaging (80% or 20/25) in excluding patients with CAD was not significantly higher than that of exercise electrocardiography (76% or 19/25). For the detection of individual vessel involvement by analysis of territories of perfusion abnormalities, the sensitivity and specificity of exercise SPECT were 72% and 96% for the left anterior descending, 78% and 85% for the right coronary, and 47% and 98% for the left circumflex artery. Ninety (group 1) of the 154 patients with CAD achieved adequate exercise end points (ischemic ST-segment depression or > 85% of maximal predicted heart rate) and 64 (group 2) did not. Exercise SPECT showed significantly more perfusion abnormalities in group 1 than in group 2 (96% vs 75%, p < 0.001). We conclude that: (1) exercise SPECT thallium imaging is more sensitive than exercise electrocardiography for detecting patients with CAD; (2) the sensitivity of the test is affected by the level of exercise; and (3) it is valuable in the identification of individual vessel involvement.

  8. Cleanliness of disposable vs nondisposable electrocardiography lead wires in children.

    PubMed

    Addison, Nancy; Quatrara, Beth; Letzkus, Lisa; Strider, David; Rovnyak, Virginia; Syptak, Virginia; Fuzy, Lisa

    2014-09-01

    Mediastinitis costs hospitals thousands of dollars a year and increases the incidence of patient morbidity and mortality. No studies have been done to evaluate adenosine triphosphate (ATP) counts on disposable and nondisposable electrocardiography (ECG) lead wires in pediatric patients. To compare the cleanliness of disposable and nondisposable ECG lead wires in postoperative pediatric cardiac surgery patients by measuring the quantity of ATP (in relative luminescence units [RLUs]). ATP levels correlate with microbial cell counts and are used by institutions to assess hospital equipment and cleanliness. A prospective, randomized trial was initiated with approval from the institutional review board. Verbal consent was obtained from the parents/guardians for each patient. Trained nurses performed ATP swabs on the right and left upper ECG cables on postoperative days 1, 2, and 3. This study enrolled 51 patients. The disposable ECG lead wire ATP count on postoperative day 1 (median, 157 RLUs) was significantly lower (P < .001) than the count for nondisposable ATP lead wires (median, 610 RLUs). On postoperative day 2, the ATP count for the disposable ECG lead wires (median, 200 RLUs) was also lower (P = .06) than the count for the nondisposable ECG lead wires (median, 453 RLUs). Results of this study support the use of disposable ECG lead wires in postoperative pediatric cardiac surgery patients for at least the first 48 hours as a direct strategy to reduce the ATP counts on ECG lead wires. ©2014 American Association of Critical-Care Nurses.

  9. Differential Prognostic Value of Coronary Computed Tomography Angiography in Relation to Exercise Electrocardiography in Asymptomatic Subjects

    PubMed Central

    Lee, Sang-Eun; Cho, Iksung; Hong, Geu-Ru; Sung, Ji Min; Cho, In-Jeong; Shim, Chi Young; Choi, Byoung Wook; Chung, Namsik

    2015-01-01

    Background To explore the prognostic performance of coronary computed tomography angiography (CCTA) and exercise electrocardiography (XECG) in asymptomatic subjects. Methods We retrospectively enrolled 812 (59 ± 9 years, 60.8% male) asymptomatic subjects who underwent CCTA and XECG concurrently from 2003 through 2009. Subjects were followed-up for major adverse cardiac events (MACE) including cardiac death, nonfatal myocardial infarction, unstable angina, and revascularization after 90 days from index CCTA. Results The prevalence of occult coronary artery disease (CAD) detected by CCTA was 17.5% and 120 subjects (14.8%) had positive XECG. During a mean follow-up of 37 ± 16 months, nine subjects experienced MACE. In multivariable Cox-regression analysis, only the presence of CAD by CCTA independently predicted future MACE (p = 0.002). Moreover, CAD by CCTA improved the predictive value when added to a clinical risk factor model using the likelihood ratio test (p < 0.001). Notably, the prognostic value of CCTA persisted in the moderate-to-high-risk group as classified by the Duke treadmill score (p = 0.040), but not in the low-risk group (p = 0.991). Conclusion CCTA provides incremental prognostic benefit over and above XECG in an asymptomatic population, especially for those in a moderate-to-high-risk group as classified by the Duke treadmill score. Risk stratification using XECG may prove valuable for identifying asymptomatic subjects who can benefit from CCTA. PMID:26755933

  10. The use of non-invasive fetal electrocardiography in diagnosing second-degree fetal atrioventricular block.

    PubMed

    Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando

    2017-01-01

    Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.

  11. The role of electrocardiography in evaluation of severity of chronic obstructive pulmonary disease in daily clinical practice.

    PubMed

    Aktürk, Faruk; Bıyık, İsmail; Kocaş, Cüneyt; Ertürk, Mehmet; Yalçın, Ahmet Arif; Savaş, Ayfer Utku; Kuzer, Firuzan Pınar; Uzun, Fatih; Yıldırım, Aydın; Uslu, Nevzat; Çuhadaroğlu, Çağlar

    2013-01-01

    Chronic obstructive pulmonary disease (COPD) is the fourth leading cause of chronic morbidity and mortality. Bronchial obstruction and increased pulmonary vascular resistance impairs right atrial functions. In this study, we aimed to investigate the effect of bronchial obstruction on p wave axis in patients with COPD and usefulness of electrocardiography (ECG) in the evaluation of the severity of COPD. Ninety five patients (64 male and 31 female) included to the study. Patients were in sinus rhythm, with normal ejection fraction and heart chamber sizes. Their respiratory function tests and 12 lead electrocardiograms were obtained at same day. Correlations with severity of COPD and ECG findings including p wave axis, p wave duration, QRS axis, QRS duration were studied. The mean age was 58 ± 12 years. Their mean p wave axis was 62 ± 18 degrees. In this study, p wave axis has demonstrated significant positive correlations with stages of COPD and QRS axis but significant negative correlations with FEV1, FEF, BMI and QRS duration. P wave axis increases with increasing stages of COPD. Verticalization of the frontal p wave axis may be an early finding of worsening of COPD before occurrences of other ECG changes of hypertrophy and enlargement of right heart chambers such as p pulmonale. Verticalization of the frontal p wave axis reflecting right atrial electrical activity and right heart strain may be a useful parameter for quick estimation of the severity of COPD in an out-patient cared.

  12. T wave amplitude in lead aVR as a novel diagnostic marker for cardiac sarcoidosis.

    PubMed

    Tanaka, Yoshihiro; Konno, Tetsuo; Yoshida, Shohei; Tsuda, Toyonobu; Sakata, Kenji; Furusho, Hiroshi; Takamura, Masayuki; Yoshimura, Kenichi; Yamagishi, Masakazu; Hayashi, Kenshi

    2017-03-01

    It is vital to identify cardiac involvement (CI) in patients with sarcoidosis as the condition could initially lead to sudden cardiac death. Although the T wave amplitude in lead aVR (TWAaVR) is reportedly associated with adverse cardiac events in various cardiovascular diseases, only scarce data are available concerning the utility of lead aVR in identifying CI in patients with sarcoidosis. We retrospectively investigated the diagnostic values of TWAaVR in patients with sarcoidosis in comparison with conventional electrocardiography parameters such as bundle branch block (BBB). From January 2006 to December 2014, 93 consecutive patients with sarcoidosis were enrolled (mean age, 55.7 ± 15.7 years; male, 31 %; cardiac involvement, n = 26). TWAaVR showed the greatest sensitivity (39 %) and specificity (92 %) in distinguishing between sarcoidosis patients with and without CI, at a cutoff value of -0.08 mV. The diagnostic value of BBB for cardiac involvement was significantly improved when combined with TWAaVR (sensitivity: 61-94 %, specificity: 97-89 %, area under the curve: 0.79-0.92, p = 0.018). Multivariate logistic regression analysis indicated that TWAaVR and BBB were independent electrocardiography parameters associated with CI. In summary, we observed that sarcoidosis patients exhibiting a high TWAaVR were likely to have CI. Thus, the application of a combination of BBB with TWAaVR may be useful when screening for CI in sarcoidosis patients.

  13. War, Medicine, and Cultural Diplomacy in the Americas: Frank Wilson and Brazilian cardiology.

    PubMed

    Kropf, Simone P; Howell, Joel D

    2017-10-01

    American cultural diplomacy played a key role in the institutionalization of Brazilian cardiology. In 1942, Frank Wilson, an internationally recognized pioneer in electrocardiography, made an extended wartime visit to Rio de Janeiro and São Paulo. The visit was sponsored by the United States Department of State as part of Roosevelt's Good Neighbor Policy and brought Wilson together with a group of physicians who would establish the specialty of cardiology in Brazil. This US cultural and diplomatic initiative strengthened an academic network that was already evolving and would eventually prove to be of benefit to both sides. Latin American physicians began in the 1920s to visit Wilson's laboratory at the University of Michigan, where they established the relationships on which Wilson would build. While affiliation with the "Wilson school" advanced the cause of Brazilian cardiologists who sought to establish themselves as specialists, cooperation with Latin American physicians benefitted Wilson in his pursuit of wider recognition for his innovations in the use of electrocardiography (ECG). Wilson's identity as a scientific ambassador to Latin America helped in legitimating his approach to the clinical application of the ECG. A close examination of Wilson's relationship to Brazilian cardiology demonstrates the role played by science and medicine as a part of wartime cultural diplomacy, as well as the dynamics of the transnational circulation of scientific knowledge and practices. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    PubMed

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p <0.0001 for the other structures). Non-ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  15. Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.

    PubMed

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Serrano, Luis; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2010-11-01

    The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.

  16. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors

    PubMed Central

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Summary Background Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Material/Methods Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Results Motion artifacts were significantly reduced for all structures by ECG gating (p=0.0089 for the lungs and p<0.0001 for the other structures). Non-ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion (p=0.03). Conclusions ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures. PMID:27920842

  17. The Application of Root Mean Square Electrocardiography (RMS ECG) for the Detection of Acquired and Congenital Long QT Syndrome

    PubMed Central

    Lux, Robert L.; Sower, Christopher Todd; Allen, Nancy; Etheridge, Susan P.; Tristani-Firouzi, Martin; Saarel, Elizabeth V.

    2014-01-01

    Background Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential duration while the RMS T wave width (TW) tracks the dispersion of repolarization timing. Here, we tested the precision of RMS ECG to assess ventricular repolarization in humans in the setting of drug-induced and congenital Long QT Syndrome (LQTS). Methods RMS ECG signals were derived from high-resolution 24 hour Holter monitor recordings from 68 subjects after receiving placebo and moxifloxacin and from standard 12 lead ECGs obtained in 97 subjects with LQTS and 97 age- and sex-matched controls. RTPK, QTRMS and RMS TW intervals were automatically measured using custom software and compared to traditional QT measures using lead II. Results All measures of repolarization were prolonged during moxifloxacin administration and in LQTS subjects, but the variance of RMS intervals was significantly smaller than traditional lead II measurements. TW was prolonged during moxifloxacin and in subjects with LQT-2, but not LQT-1 or LQT-3. Conclusion These data validate the application of RMS ECG for the detection of drug-induced and congenital LQTS. RMS ECG measurements are more precise than the current standard of care lead II measurements. PMID:24454918

  18. The application of root mean square electrocardiography (RMS ECG) for the detection of acquired and congenital long QT syndrome.

    PubMed

    Lux, Robert L; Sower, Christopher Todd; Allen, Nancy; Etheridge, Susan P; Tristani-Firouzi, Martin; Saarel, Elizabeth V

    2014-01-01

    Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential duration while the RMS T wave width (TW) tracks the dispersion of repolarization timing. Here, we tested the precision of RMS ECG to assess ventricular repolarization in humans in the setting of drug-induced and congenital Long QT Syndrome (LQTS). RMS ECG signals were derived from high-resolution 24 hour Holter monitor recordings from 68 subjects after receiving placebo and moxifloxacin and from standard 12 lead ECGs obtained in 97 subjects with LQTS and 97 age- and sex-matched controls. RTPK, QTRMS and RMS TW intervals were automatically measured using custom software and compared to traditional QT measures using lead II. All measures of repolarization were prolonged during moxifloxacin administration and in LQTS subjects, but the variance of RMS intervals was significantly smaller than traditional lead II measurements. TW was prolonged during moxifloxacin and in subjects with LQT-2, but not LQT-1 or LQT-3. These data validate the application of RMS ECG for the detection of drug-induced and congenital LQTS. RMS ECG measurements are more precise than the current standard of care lead II measurements.

  19. A direct comparison of efficacy between desloratadine and rupatadine in seasonal allergic rhinoconjunctivitis: a randomized, double-blind, placebo-controlled study.

    PubMed

    Lukat, Kf; Rivas, P; Roger, A; Kowalski, Ml; Botzen, U; Wessel, F; Sanquer, F; Agache, I; Izquierdo, I

    2013-01-01

    H1-antihistamines are recommended as the first-line symptomatic treatment of allergic rhinitis. The objective of this study was to evaluate the effects of rupatadine (RUP) versus desloratadine (DES) in subjects with seasonal allergic rhinitis (SAR). To assess the efficacy and safety of RUP in SAR in comparison with placebo (PL) and DES. A randomized, double-blind, multicenter, international, and PL-controlled study was carried out. The main selection criteria included SAR patients over 12 years old with a positive prick test to a relevant seasonal allergen for the geographic area. Symptomatic patients at screening with a nasal symptom sum score of ≥6 points (nasal discharge, nasal obstruction, sneezing, and nasal pruritus), a non-nasal score of ≥3 points (ocular pruritus, ocular redness, and tearing eyes), and a rhinorrhea score of ≥2 points with laboratory test results and electrocardiography within acceptable limits were included in the study. Change from baseline in the total symptom-score (T7SS) over the 4-week treatment period (reflective evaluation) was considered the primary efficacy variable. Secondary efficacy measures included total nasal symptom score (T4NSS) and conjunctival symptom score (T3NNSS), both of which are reflective and instantaneous evaluations. Furthermore questions related to quality of life (eg, sleep disturbances or impairment of daily activities) have also been evaluated. Safety was assessed according to adverse events reported, as well as laboratory and electrocardiography controls. A total of 379 patients were randomized, of which 356 were included and allocated to PL (n = 122), RUP (n = 117), or DES (n = 117). Mean change of T7SS over the 4-week treatment period was significantly reduced in the RUP (-46.1%, P = 0.03) and DES (-48.9%, P = 0.01) groups, compared with PL. Similarly, RUP and DES were comparable and significantly superior to PL for all secondary endpoints, including nasal and conjunctival symptoms and patients' and investigator's overall clinical opinions. Symptom score evaluation (both reflective and instantaneous evaluations) throughout the treatment period showed a progressive and maintained significant improvement with both treatments at day 7 (P = 0.01), day 14 (P = 0.007), and day 21 (P = 0.01) in comparison with PL. Adverse events were scarce and were similar in both treatment groups. Electrocardiography (QTc) and lab test results did not show any relevant findings. RUP is a very good choice for SAR due to its contribution to the improvement of nasal (including obstruction) and non-nasal symptoms to a similar degree as DES.

  20. Acute renal infarction from a cardiac thrombus.

    PubMed

    Nasser, Nicola J; Abadi, Sobhi; Azzam, Zaher S

    2007-11-01

    A 53-year-old man presented to hospital 2 hours after the abrupt onset of left upper abdominal pain. He was treated with analgesics and discharged after 4 hours of observation, but presented to another hospital 2 hours later with severe left abdominal pain. His past medical history included ischemic dilated cardiomyopathy due to recurrent myocardial infarction. Physical examination, electrocardiography, laboratory investigations, contrast-enhanced computed tomography, and transesophageal echocardiography. Renal artery thromboembolism resulting from dilated cardiomyopathy, severely reduced cardiac function and an intracardiac thrombus. Anticoagulation with unfractionated heparin followed by enoxaparin and warfarin.

  1. Discrimination of the "Athlete's Heart" from real disease by electrocardiogram and echocardiogram.

    PubMed

    Erickson, Christopher C

    2017-01-01

    Chronic physical training has been shown to produce multiple changes in the heart, resulting in the athlete's heart phenotype. Some of the changes can make it difficult to discern athlete's heart from true cardiac disease, most notably hypertrophic cardiomyopathy. Other diseases such as dilated cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy may be difficult to rule in or out. In this article, the physiological cardiac changes of chronic athletic training are reviewed. A methodological approach using electrocardiography and echocardiography to differentiate between athlete's heart and cardiac disease is proposed.

  2. ST segment elevation in lead aVR: what to expect from this orphan?

    PubMed

    Iskandar, Said B; Fahrig, Stephen A

    2008-12-01

    Standard 12-lead electrocardiography is used to diagnose acute myocardial infarctions in patient presenting with ST elevation. The specificity of ST segment elevation for the corresponding area is more than 90 percent. It has been suggested that ST-segment elevation in lead aVR may indicate left main disease. We will present a patient who had an ST segment elevation in this lead. We will review the current data about this finding, as well as the significance of ST segment elevation in other leads.

  3. Some Electrophysiological Methods for Studying the Action of Narcotic Agents in Animals, with special reference to Industrial Solvents: A Review

    PubMed Central

    Mikisková, Hana; Mikiska, Aloš

    1968-01-01

    Four electrophysiological methods, two based on stimulation (measurement of spinal reflex excitability and of direct excitability of the cerebral motor cortex) and two based on bioelectric recording (electro-encephalography and electrocardiography), were used in intact guinea-pigs and rabbits for studying the action of narcotic and anaesthetic agents, especially of industrial solvents. The authors' results have been reviewed and compared with those of other investigators in an attempt to work out experimental procedures for routine toxicity testing. PMID:4296739

  4. Hyperkalemia by Euro-Collins solution in anesthesia for renal transplantation: a case report.

    PubMed

    Hirata, Eunice Sizue; Pereira, Rosa Inês Costa; Filho, Gentil Alves; Braga, Angélica de Fátima Assunção

    2013-01-01

    To describe anesthesia for renal transplantation that progressed to a sharp potassium increase after kidney reperfusion with Euro-Collins' solution in the operative field. We will also report on diagnosis and treatment used. The use of infusion solutions in the surgical field requires careful monitoring, such as electrocardiography, measurement of serum potassium, and availability of calcium gluconate, insulin, and albuterol for immediate use. The replacement of Euro-Collins' solution for saline solution immediately before the implant may be a useful option in patients with high levels of potassium.

  5. Severe hyperkalemia can be detected immediately by quantitative electrocardiography and clinical history in patients with symptomatic or extreme bradycardia: a retrospective cross-sectional study.

    PubMed

    Chon, Sung-Bin; Kwak, Young Ho; Hwang, Seung-Sik; Oh, Won Sup; Bae, Jun-Ho

    2013-12-01

    Detecting severe hyperkalemia is challenging. We explored its prevalence in symptomatic or extreme bradycardia and devised a diagnostic rule. This retrospective cross-sectional study included patients with symptomatic (heart rate [HR] ≤ 50/min with dyspnea, chest pain, altered mentality, dizziness/syncope/presyncope, general weakness, oliguria, or shock) or extreme (HR ≤ 40/min) bradycardia at an emergency department for 46 months. Risk factors for severe hyperkalemia were chosen by multiple logistic regression analysis from history (sex, age, comorbidities, and medications), vital signs, and electrocardiography (ECG; maximum precordial T-wave amplitude, PR, and QRS intervals). The derived diagnostic index was validated using bootstrapping method. Among the 169 participants enrolled, 87 (51.5%) were female. The mean (SD) age was 71.2 (12.5) years. Thirty-six (21.3%) had severe hyperkalemia. The diagnostic summed "maximum precordial T ≥ 8.5 mV (2)," "atrial fibrillation/junctional bradycardia (1)," "HR ≤ 42/min (1)," "diltiazem medication (2)," and "diabetes mellitus (1)." The C-statistics were 0.86 (0.80-0.93) and were validated. For scores of 4 or higher, sensitivity was 0.50, specificity was 0.92, and positive likelihood ratio was 6.02. The "ECG-only index," which sums the 3 ECG findings, had a sensitivity of 0.50, specificity of 0.90, and likelihood ratio (+) of 5.10 for scores of 3 or higher. Severe hyperkalemia is prevalent in symptomatic or extreme bradycardia and detectable by quantitative electrocardiographic parameters and history. © 2013.

  6. Review of systems, physical examination, and routine tests for case-finding in ambulatory patients.

    PubMed

    Boland, B J; Wollan, P C; Silverstein, M D

    1995-04-01

    The screening value of the comprehensive review of systems and the complete physical examination in detecting unsuspected diseases for which therapeutic interventions are initiated has not been formally studied in ambulatory patients. The medical records of 100 randomly selected adult patients who had an ambulatory general medical evaluation at the Mayo Clinic in 1990-1991 were surveyed to compare review of systems and physical examination with routine laboratory tests, chest radiography, and electrocardiography as case-finding maneuvers. The main outcome measure was the therapeutic yield of each case-finding maneuver, defined as the proportion of maneuvers leading to a new therapy for a new clinically important diagnosis. The utilization rate of routine tests in the 100 patients (mean age: 59 +/- 16 years; 58% women) was high, ranging from 77 to 98%. Overall, the case-finding maneuvers led to 36 unsuspected clinically important diagnoses and resulted in 25 new therapeutic interventions. Higher therapeutic yield was observed for review of systems (7%), physical examination (5%), and lipid screening (9.2%) than for chemistry group (2.2%), complete blood count (1.8%), thyroid tests (1.5%), urinalysis (1.1%), electrocardiography (0%), or chest radiography (0%). The number of therapeutic interventions was not associated with patient's age (P = 0.55), sex (P = 0.88), comorbidity (P = 0.30) or with the time interval since the last general medical evaluation (P = 0.12). Based on therapeutic yield, these data suggest that review of systems and physical examination are valuable case-finding maneuvers in the periodic medical evaluation of ambulatory patients.

  7. Comparison of Left Ventricular Hypertrophy by Electrocardiography and Echocardiography in Children Using Analytics Tool.

    PubMed

    Tague, Lauren; Wiggs, Justin; Li, Qianxi; McCarter, Robert; Sherwin, Elizabeth; Weinberg, Jacqueline; Sable, Craig

    2018-05-17

    Left ventricular hypertrophy (LVH) is a common finding on pediatric electrocardiography (ECG) leading to many referrals for echocardiography (echo). This study utilizes a novel analytics tool that combines ECG and echo databases to evaluate ECG as a screening tool for LVH. SQL Server 2012 data warehouse incorporated ECG and echo databases for all patients from a single institution from 2006 to 2016. Customized queries identified patients 0-18 years old with LVH on ECG and an echo performed within 24 h. Using data visualization (Tableau) and analytic (Stata 14) software, ECG and echo findings were compared. Of 437,699 encounters, 4637 met inclusion criteria. ECG had high sensitivity (≥ 90%) but poor specificity (43%), and low positive predictive value (< 20%) for echo abnormalities. ECG performed only 11-22% better than chance (AROC = 0.50). 83% of subjects with LVH on ECG had normal left ventricle (LV) structure and size on echo. African-Americans with LVH were least likely to have an abnormal echo. There was a low correlation between V 6 R on ECG and echo-derived Z score of left ventricle diastolic diameter (r = 0.14) and LV mass index (r = 0.24). The data analytics client was able to mine a database of ECG and echo reports, comparing LVH by ECG and LV measurements and qualitative findings by echo, identifying an abnormal LV by echo in only 17% of cases with LVH on ECG. This novel tool is useful for rapid data mining for both clinical and research endeavors.

  8. Electrocardiographic consequences of cardiac iron overload in thalassemia major

    PubMed Central

    Detterich, Jon; Noetzli, Leila; Dorey, Fred; Bar-Cohen, Yaniv; Harmatz, Paul; Coates, Thomas; Wood, John

    2011-01-01

    Background Iron cardiomyopathy is a leading cause of death in transfusion dependent thalassemia major (TM) patients and MRI (T2*) can recognize preclinical cardiac iron overload, but, is unavailable to many centers. Design and Methods We evaluated the ability of 12-lead electrocardiography to predict cardiac iron loading in TM. 12-lead electrocardiogram and cardiac T2* measurements were performed prospectively, with a detectable cardiac iron cutoff of T2*less than 20 ms. Patients with and without cardiac iron were compared using two-sample statistics and against population norms using age and gender-matched Z-scores. Results 45/78 patients had detectable cardiac iron. Patients having cardiac iron were older and more likely female but had comparable liver iron burdens and serum ferritin. Increased heart rate (HR) and prolonged corrected QT interval (QTc) were present, regardless of cardiac iron status. Repolarization abnormalities were the strongest predictors of cardiac iron, including QT/QTc prolongation, left shift of T-wave axis, and interpretation of ST/T-wave morphology. Recursive partitioning of the data for females using T-axis and HR and for males using QT, HR and T-axis produced algorithms with AUROC’s of 88.3 and 87.1 respectively. Conclusions Bradycardia and repolarization abnormalities on 12-lead electrocardiography were the most specific markers for cardiac iron in thalassemia major. Changes in these variables may be helpful to stratify cardiac risk when cardiac MRI is unavailable. However, diagnostic algorithms need to be vetted on larger and more diverse patient populations and longitudinal studies are necessary to determine reversibility of the observed abnormalities. PMID:22052662

  9. Development of electrocardiogram intervals during growth of FVB/N neonate mice

    PubMed Central

    2010-01-01

    Background Electrocardiography remains the best diagnostic tool and therapeutic biomarker for a spectrum of pediatric diseases involving cardiac or autonomic nervous system defects. As genetic links to these disorders are established and transgenic mouse models produced in efforts to understand and treat them, there is a surprising lack of information on electrocardiograms (ECGs) and ECG abnormalities in neonate mice. This is likely due to the trauma and anaesthesia required of many legacy approaches to ECG recording in mice, exacerbated by the fragility of many mutant neonates. Here, we use a non-invasive system to characterize development of the heart rate and electrocardiogram throughout the growth of conscious neonate FVB/N mice. Results We examine ECG waveforms as early as two days after birth. At this point males and females demonstrate comparable heart rates that are 50% lower than adult mice. Neonatal mice exhibit very low heart rate variability. Within 12 days of birth PR, QRS and QTc interval durations are near adult values while heart rate continues to increase until weaning. Upon weaning FVB/N females quickly develop slower heart rates than males, though PR intervals are comparable between sexes until a later age. This suggests separate developmental events may contribute to these gender differences in electrocardiography. Conclusions We provide insight with a new level of detail to the natural course of heart rate establishment in neonate mice. ECG can now be conveniently and repeatedly used in neonatal mice. This should serve to be of broad utility, facilitating further investigations into development of a diverse group of diseases and therapeutics in preclinical mouse studies. PMID:20735846

  10. [Late arrhythmias in the operated interatrial communication. Analysis of sinus node function and the conduction pathways by His bundle electrocardiography].

    PubMed

    Ramírez, A; Gil, M; Martínez Ríos, M A; Cárdenas, M; Pliego, J; Zamora, C; Mata, L A

    1982-01-01

    Four hundred patients with atrial septal defect treated surgically were reviewed. Thirty five (8.7%) developed arrhytmias post-surgery which persisted for over a year. Sinus bradycardia was found in 10 patients, nodal rhythm in 21, and atrial fibrilation and flutter in 4 patients. Thirty five per cent of the patients with late arrhythmias developed related symptomatology. In 14 patients the function of the sinus node was studied with electrical stimulation of the atrium and with His registry. The interatrial conduction time, AV node and His Purkinje were analized employing various stimulation frequencies. All the cases studied had normal intra-atrial conduction; the response of the atrio-ventricular node to increasing frequencies was normal, an the intraventricular conduction remained constant. In 8 patients (52%), alterations of the sinus node were found; these consisted of prolonged post-stimulation pauses, Wenckebach's type sinoatrial block and suppression of sinus automatism employing vagal procedures or through electrical stimulation. A patient with severe bradycardia detected by dynamic electrocardiography had to be treated with a permanent pacemaker. We confirm that these arrhytmias are not produced by lesions of the internodal tracts, and that an alteration of the sinus node is frequent without a concomitant lesion of the intraventricular pathway. The lesion to the nutrient artery could be due to trauma and/or surgically induced. The response to anticholinergic drugs was good. Prolonged observation of these patients could increase the morbility of these arrythmias and raise doubts of the surgical indications in cases with moderate hemodynamic repercussion.

  11. Clinical and molecular genetic characterisation of a family segregating autosomal dominant retinitis pigmentosa and sensorineural deafness.

    PubMed

    Kenna, P; Mansergh, F; Millington-Ward, S; Erven, A; Kumar-Singh, R; Brennan, R; Farrar, G J; Humphries, P

    1997-03-01

    To characterise clinically a large kindred segregating retinitis pigmentosa and sensorineural hearing impairment in an autosomal dominant pattern and perform genetic linkage studies in this family. Extensive linkage analysis in this family had previously excluded the majority of loci shown to be involved in the aetiologies of RP, some other forms of inherited retinal degeneration, and inherited deafness. Members of the family were subjected to detailed ophthalmic and audiological assessment. In addition, some family members underwent skeletal muscle biopsy, electromyography, and electrocardiography. Linkage analysis using anonymous microsatellite markers was performed on DNA samples from all living members of the pedigree. Patients in this kindred have a retinopathy typical of retinitis pigmentosa in addition to a hearing impairment. Those members of the pedigree examined demonstrated a subclinical myopathy, as evidence by abnormal skeletal muscle histology, electromyography, and electrocardiography. LOD scores of Zmax = 3.75 (theta = 0.10), Zmax = 3.41 (theta = 0.10), and Zmax = 3.25 (theta = 0.15) respectively were obtained with the markers D9S118, D9S121, and ASS, located on chromosome 9q34-qter, suggesting that the causative gene in this family may lie on the long arm (q) of chromosome 9. These data indicate that the gene responsible for the phenotype in this kindred is located on chromosome 9 q. These data, together with evidence that a murine deafness gene is located in a syntenic area of the mouse genome, should direct the research community to consider this area as a candidate region for retinopathy and/or deafness genes.

  12. Electrocardiographic measures of left ventricular hypertrophy in the Antihypertensive and Lipid-Lowering Treatment to Prevent Heart Attack Trial.

    PubMed

    Ernst, Michael E; Davis, Barry R; Soliman, Elsayed Z; Prineas, Ronald J; Okin, Peter M; Ghosh, Alokananda; Cushman, William C; Einhorn, Paula T; Oparil, Suzanne; Grimm, Richard H

    2016-12-01

    Left ventricular hypertrophy (LVH) predicts cardiovascular risk in hypertensive patients. We analyzed baseline/follow-up electrocardiographies in 26,376 Antihypertensive and Lipid-Lowering Treatment to Prevent Heart Attack Trial participants randomized to amlodipine (A), lisinopril (L), or chlorthalidone (C). Prevalent/incident LVH was examined using continuous and categorical classifications of Cornell voltage. At 2 and 4 years, prevalence of LVH in the C group (5.57%; 6.14%) was not statistically different from A group (2 years: 5.47%; P = .806, 4 years: 6.54%; P = .857) or L group (2 years: 5.64%; P = .857, 4 years: 6.50%; P = .430). Incident LVH followed similarly, with no difference at 2 years for C (2.99%) compared to A (2.57%; P = .173) or L (3.16%; P = .605) and at 4 years (C = 3.52%, A = 3.29%, L = 3.71%; P = .521 C vs. A, P = .618 C vs. L). Mean Cornell voltage decreased comparably across treatment groups (Δ baseline, 2 years = +3 to -27 μV, analysis of variance P = .8612; 4 years = +10 to -17 μV, analysis of variance P = .9692). We conclude that risk reductions associated with C treatment in secondary end points of the Antihypertensive and Lipid-Lowering Treatment to Prevent Heart Attack Trial cannot be attributed to differential improvements in electrocardiography LVH. Copyright © 2016 American Society of Hypertension. All rights reserved.

  13. Myocardial infarction size and location: a comparative study of epicardial isopotential mapping, thallium-201 scintigraphy, electrocardiography and vectorcardiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toyama, S.; Suzuki, K.; Takahashi, T.

    1987-07-01

    Based on epicardial isopotential mapping (the Ep Map), which was calculated from body surface isopotential mapping (the Body Map) with Yamashita's method, using the finite element technique, we predicted the location and size of the abnormal depolarized area (the infarcted area) in 19 clinical cases of anterior and 18 cases of inferoposterior infarction. The prediction was done using Toyama's diagnostic method, previously reported. The accuracy of the prediction by the Ep Map was assessed by comparing it with findings from thallium-201 scintigraphy (SCG), electrocardiography (ECG) and vectorcardiography (VCG). In all cases of anterior infarction, the location of the abnormal depolarizedmore » areas determined on the Ep Map, which was localized at the anterior wall along the anterior intraventricular septum, agreed with the location of the abnormal findings obtained by SCG, ECG and VCG. For all inferoposterior infarction cases, the abnormal depolarized areas were localized at the posterior wall and the location also coincided with that of the abnormal findings obtained by SCG, ECG and VCG. Furthermore, we ranked and ordered the size of the abnormal depolarized areas, which were predicted by the Ep Map for both anterior and inferoposterior infarction cases. In the cases of anterior infarction, the order of the size of the abnormal depolarized area by the Ep Map was correlated to the size of the abnormal findings by SCG, as well as to the results from Selvester's QRS scoring system in ECG and to the angle of the maximum QRS vector in the horizontal plane in VCG.« less

  14. Cost-benefit and cost-savings analyses of antiarrhythmic medication monitoring.

    PubMed

    Snider, Melissa; Carnes, Cynthia; Grover, Janel; Davis, Rich; Kalbfleisch, Steven

    2012-09-15

    The economic impact of pharmacist-managed antiarrhythmic drug therapy monitoring on an academic medical center's electrophysiology (EP) program was investigated. Data were collected for the initial two years of patient visits (n = 816) to a pharmacist-run clinic for antiarrhythmic drug therapy monitoring. A retrospective cost analysis was conducted to assess the direct costs associated with three appointment models: (1) a clinic office visit only, (2) a clinic visit involving electrocardiography and basic laboratory tests, and (3) a clinic visit including pulmonary function testing and chest x-rays in addition to electrocardiography and laboratory testing. A subset of patient cases (n = 18) were included in a crossover analysis comparing pharmacist clinic care and usual care in an EP physician clinic. The primary endpoints were the cost benefits and cost savings associated with pharmacy-clinic care versus usual care. A secondary endpoint was improvement of overall EP program efficiency. The payer mix was 61.6% (n = 498) Medicare, 33.2% (n = 268) managed care, and 5.2% (n = 42) other. Positive contribution margins were demonstrated for all appointment models. The pharmacist-managed clinic also yielded cost savings by reducing overall patient care charges by 21% relative to usual care. By the second year, the pharmacy clinic improved EP program efficiency by scheduling an average of 24 patients per week, in effect freeing up one day per week of EP physician time to spend on other clinical activities. Pharmacist monitoring of antiarrhythmic drug therapy in an out-patient clinic provided cost benefits, cost savings, and improved overall EP program efficiency.

  15. History of research in Japan on electrocardiography in the racehorse

    PubMed Central

    HIRAGA, Atsushi; SUGANO, Shigeru

    2015-01-01

    ABSTRACT Since the first recording of electrocardiograms (ECGs) of a horse in Japan was carried out in 1944, studies on ECGs have been performed intensively. During the early stages of research from the 1950s to 1960s, leads to use for ECG recording were evaluated using several different approaches including unipolar leads, bipolar limb leads, and bipolar chest leads. Based on these studies, the AB lead, which is oriented along the long axis of the heart, became the standard reference method in Japan. Electrodes of the AB lead are placed on the upper 1/4th point along a straight line between the withers and the left shoulder blade (base: B), and 10 cm posterior to the left olecranon (apex: A). The incidence of equine arrhythmias among racehorses has been surveyed, and details of the electrocardiographic characteristics of several arrhythmias have been investigated. In particular, atrial fibrillation (AF) has been extensively studied, and papers have reported findings such as that paroxysmal AF occurs during racing and described electrocardiographic changes that occur at the onset of AF during exercise. Development of a radiotelemetry system for ECG recording enabled the first recording of equine ECGs during galloping in 1964, the detection of arrhythmias, and calculation of heart rate during exercise. Studies on comparative and developmental changes of ECGs have described characteristics of the equine ECGs. Future research on changes in cardiac function, including autonomic function, that occur with aging may lead to new developments in equine electrocardiography and contribute to improving the health and welfare of the horse. PMID:25829865

  16. Smartphone ECG for evaluation of STEMI: results of the ST LEUIS Pilot Study.

    PubMed

    Muhlestein, Joseph Boone; Le, Viet; Albert, David; Moreno, Fidela Ll; Anderson, Jeffrey L; Yanowitz, Frank; Vranian, Robert B; Barsness, Gregory W; Bethea, Charles F; Severance, Harry W; Ramo, Barry; Pierce, John; Barbagelata, Alejandro; Muhlestein, Joseph Brent

    2015-01-01

    12-lead ECG is a critical component of initial evaluation of cardiac ischemia, but has traditionally been limited to large, dedicated equipment in medical care environments. Smartphones provide a potential alternative platform for the extension of ECG to new care settings and to improve timeliness of care. To gain experience with smartphone electrocardiography prior to designing a larger multicenter study evaluating standard 12-lead ECG compared to smartphone ECG. 6 patients for whom the hospital STEMI protocol was activated were evaluated with traditional 12-lead ECG followed immediately by a smartphone ECG using right (VnR) and left (VnL) limb leads for precordial grounding. The AliveCor™ Heart Monitor was utilized for this study. All tracings were taken prior to catheterization or immediately after revascularization while still in the catheterization laboratory. The smartphone ECG had excellent correlation with the gold standard 12-lead ECG in all patients. Four out of six tracings were judged to meet STEMI criteria on both modalities as determined by three experienced cardiologists, and in the remaining two, consensus indicated a non-STEMI ECG diagnosis. No significant difference was noted between VnR and VnL. Smartphone based electrocardiography is a promising, developing technology intended to increase availability and speed of electrocardiographic evaluation. This study confirmed the potential of a smartphone ECG for evaluation of acute ischemia and the feasibility of studying this technology further to define the diagnostic accuracy, limitations and appropriate use of this new technology. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Ability of a 5-minute electrocardiography (ECG) for predicting arrhythmias in Doberman Pinschers with cardiomyopathy in comparison with a 24-hour ambulatory ECG.

    PubMed

    Wess, G; Schulze, A; Geraghty, N; Hartmann, K

    2010-01-01

    Ventricular premature contractions (VPCs) are common in the occult stage of cardiomyopathy in Doberman Pinschers. Although the gold standard for detecting arrhythmia is the 24-hour ambulatory electrocardiography (ECG) (Holter), this method is more expensive, time-consuming and often not as readily available as common ECG. Comparison of 5-minute ECGs with Holter examinations. Eight hundred and seventy-five 5-minute ECGs and Holter examinations of 431 Doberman Pinschers. Each examination included a 5-minute ECG and Holter examination. A cut-off value of > 100 VPCs/24 hours using Holter was considered diagnostic for the presence of cardiomyopathy. Statistical evaluation included calculation of sensitivity, specificity, positive predictive value, and negative predictive value. Holter examinations revealed > 100 VPCs/24 hours in 204/875 examinations. At least 1 VPC during a 5-minute ECG was detected in 131 (64.2%) of these 204 examinations. No VPCs were found in the 5-minute ECG in 73 (35.8%) examinations of affected Doberman Pinschers. A 5-minute ECG with at least 1 VPC as cut-off had a sensitivity of 64.2%, a specificity of 96.7%, a positive predictive value of 85.6% and a negative predictive value of 89.9% for the presence of > 100 VPCs/24 hours. A 5-minute ECG is a rather insensitive method for detecting arrhythmias in Doberman Pinschers. However, the occurrence of at least 1 VPC in 5 minutes strongly warrants further examination of the dog, because specificity (96.7%) and positive predictive value (85.6%) are high and could suggest occult cardiomyopathy.

  18. Study design and rationale for biomedical shirt-based electrocardiography monitoring in relevant clinical situations: ECG-shirt study.

    PubMed

    Balsam, Paweł; Lodziński, Piotr; Tymińska, Agata; Ozierański, Krzysztof; Januszkiewicz, Łukasz; Główczyńska, Renata; Wesołowska, Katarzyna; Peller, Michał; Pietrzak, Radosław; Książczyk, Tomasz; Borodzicz, Sonia; Kołtowski, Łukasz; Borkowski, Mariusz; Werner, Bożena; Opolski, Grzegorz; Grabowski, Marcin

    2018-01-01

    Today, the main challenge for researchers is to develop new technologies which may help to improve the diagnoses of cardiovascular disease (CVD), thereby reducing healthcare costs and improving the quality of life for patients. This study aims to show the utility of biomedical shirt-based electrocardiography (ECG) monitoring of patients with CVD in different clinical situations using the Nuubo® ECG (nECG) system. An investigator-initiated, multicenter, prospective observational study was carried out in a cardiology (adult and pediatric) and cardiac rehabilitation wards. ECG monitoring was used with the biomedical shirt in the following four independent groups of patients: 1) 30 patients after pulmonary vein isolation (PVI), 2) 30 cardiac resynchronization therapy (CRT) recipients, 3) 120 patients during cardiac rehabilitation after myocardial infarction, and 4) 40 pediatric patients with supraventricular tachycardia (SVT) before electrophysiology study. Approval for all study groups was obtained from the institutional review board. The biomedical shirt captures the electrocardiographic signal via textile electrodes integrated into a garment. The software allows the visualization and analysis of data such as ECG, heart rate, arrhythmia detecting algorithm and relative position of the body is captured by an electronic device. The major advantages of the nECG system are continuous ECG monitoring during daily activities, high quality of ECG recordings, as well as assurance of a proper adherence due to adequate comfort while wearing the shirt. There are only a few studies that have examined wearable systems, especially in pediatric populations. This study is registered in ClinicalTrials.gov: Identifier NCT03068169. (Cardiol J 2018; 25, 1: 52-59).

  19. Neurotechnology to accelerate learning: during marksmanship training.

    PubMed

    Behneman, Adrienne; Berka, Chris; Stevens, Ronald; Vila, Bryan; Tan, Veasna; Galloway, Trysha; Johnson, Robin; Raphael, Giby

    2012-01-01

    This article explores the psychophysiological metrics during expert and novice performances in marksmanship, combat deadly force judgment and decision making (DFJDM), and interactions of teams. Electroencephalography (EEG) and electrocardiography (ECG) are used to characterize the psychophysiological profiles within all categories. Closed-loop biofeedback was administered to accelerate learning during marksmanship training in which the results show a difference in groups that received feedback compared with the control. During known distance marksmanship and DFJDM scenarios, experts show superior ability to control physiology to meet the demands of the task. Expertise in teaming scenarios is characterized by higher levels of cohesiveness than those seen in novices.

  20. Time to treatment and acute coronary syndromes: bridging the gap in rapid decision making.

    PubMed

    Peacock, W Frank

    2010-01-01

    The role of cardiac biomarkers in the diagnosis, risk stratification, and treatment of patients with chest pain and suspected acute coronary syndromes (ACS) has continued to evolve. Although it is clear that troponin (Tn) measurement provides independent prognostic information in patients with suspected ACS, it is less well established that early B-type natriuretic peptide (BNP) measurement provides additional incremental prognostic information above and beyond electrocardiography and Tn measurement. It is useful to identify patients at high risk for adverse events through measurement of Tn and BNP levels so that timely treatment decisions can be made.

  1. Biomedical engineering tasks. [electrode development for electrocardiography and electroencephalography

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Electrocardiographic and vectorcardiographic bioinstrumentation work centered on the development of a new electrode system harness for Project Skylab. Evaluation of several silver electrode configurations proved superior impedance voltage performance for silver/silver chloride electrodes mounted flush by using a paste adhesive. A portable ECG processor has been designed and a breadboard unit has been built to sample ECG input data at a rate of 500 samples per second for arrhythmia detection. A small real time display driver program has been developed for statistical analysis on selected QPS features. Engineering work on a sleep monitoring cap assembly continued.

  2. Freeware eLearning Flash-ECG for learning electrocardiography.

    PubMed

    Romanov, Kalle; Kuusi, Timo

    2009-06-01

    Electrocardiographic (ECG) analysis can be taught in eLearning programmes with suitable software that permits the effective use of basic tools such as a ruler and a magnifier, required for measurements. The Flash-ECG (Research & Development Unit for Medical Education, University of Helsinki, Finland) was developed to enable teachers and students to use scanned and archived ECGs on computer screens and classroom projectors. The software requires only a standard web browser with a Flash plug-in and can be integrated with learning environments (Blackboard/WebCT, Moodle). The Flash-ECG is freeware and is available to medical teachers worldwide.

  3. Dynamic right ventricular outflow tract (infundibular) stenosis and pectus excavatum in a dog

    PubMed Central

    Fournier, Tanya E.

    2008-01-01

    This is the first published report of a dog with dynamic right ventricular outflow tract (infundibular) stenosis, right ventricular hypertrophy, and pectus excavatum. A juvenile dog presented with a grade V/VI left base systolic heart murmur, tachycardia, and pectus excavatum. Diagnosis of the aforementioned conditions was based on radiography, electrocardiography, and echocardiography. At 9 1/2 wk of age the heart murmur was no longer audible and the right ventricular stenosis and hypertrophy had dissipated and regressed, respectively. Resolution may be associated with growth of the dog. A good prognosis is foreseen. PMID:18512460

  4. Effectiveness of 2-hour Troponin in High-risk Patients With Suspected Acute Coronary Syndrome.

    PubMed

    Bove, Joseph; Hochman, Steven; Miller, Jacob; Artim, Stephen

    2017-06-01

    Research has shown the safety and effectiveness of drawing a standard troponin level at presentation and again at 2 hours in only low-risk patients. Because high-sensitivity troponins are not currently approved in the United States, we studied the utility of a standard troponin that is presently in use. Our goal was to determine if 2-hour standard troponin would be safe and effective in the evaluation of a high-risk cohort of patients never studied previously. We conducted a single-center prospective observational study of adult patients presenting to the emergency department with signs and symptoms suggestive of acute coronary syndrome. Patients were defined as high risk if the attending physician planned to admit or transfer the patient to the observation unit. History, Electrocardiography, Age, Risk factors, Troponin scores were calculated on all patients to provide verification that the individuals were high risk. The primary outcome was a composite of 30-day myocardial infarction, death, cardiac arrest with return of spontaneous circulation, or dysrhythmia. The secondary outcome was 30-day revascularization. We included a total of 122 patients with an average follow-up of 112 days (minimum 30 days). A total of 86% of cases had History, Electrocardiography, Age, Risk factors, Troponin scores ≥4. The primary outcome was met in 22 (18%) patients, and the secondary outcome occurred in 7 (5.7%) patients. The negative predictive value of negative 2-hour troponins along with no significant delta troponin rise was 98.7%. Discharging patients thought to be high risk who have negative troponins at 0 and 2 hours and no delta troponin rise appears safe. No deaths occurred in follow-up. Larger studies are warranted.

  5. Normal ranges for fetal electrocardiogram values for the healthy fetus of 18-24 weeks of gestation: a prospective cohort study.

    PubMed

    Verdurmen, Kim M J; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; Delhaas, Tammo; van Laar, Judith O E H; Oei, S Guid

    2016-08-17

    The fetal anomaly ultrasound only detects 65 to 81 % of the patients with congenital heart disease, making it the most common structural fetal anomaly of which a significant part is missed during prenatal life. Therefore, we need a reliable non-invasive diagnostic method which improves the predictive value for congenital heart diseases early in pregnancy. Fetal electrocardiography could be this desired diagnostic method. There are multiple technical challenges to overcome in the conduction of the fetal electrocardiogram. In addition, interpretation is difficult due to the organisation of the fetal circulation in utero. We want to establish the normal ranges and values of the fetal electrocardiogram parameters in healthy fetuses of 18 to 24 weeks of gestation. Women with an uneventful singleton pregnancy between 18 and 24 weeks of gestation are asked to participate in this prospective cohort study. A certified and experienced sonographist performs the fetal anomaly scan. Subsequently, a fetal electrocardiogram recording is performed using dedicated signal processing methods. Measurements are performed at two institutes. We will include 300 participants to determine the normal values and 95 % confidence intervals of the fetal electrocardiogram parameters in a healthy fetus. We will evaluate the fetal heart rate, segment intervals, normalised amplitude and the fetal heart axis. Three months postpartum, we will evaluate if a newborn is healthy through a questionnaire. Fetal electrocardiography could be a promising tool in the screening program for congenital heart diseases. The electrocardiogram is a depiction of the intimate relationship between the cardiac nerve conduction pathways and the structural morphology of the fetal heart, and therefore particularly suitable for the detection of secondary effects due to a congenital heart disease (hypotrophy, hypertrophy and conduction interruption).

  6. Long-range non-contact imaging photoplethysmography: cardiac pulse wave sensing at a distance

    NASA Astrophysics Data System (ADS)

    Blackford, Ethan B.; Estepp, Justin R.; Piasecki, Alyssa M.; Bowers, Margaret A.; Klosterman, Samantha L.

    2016-03-01

    Non-contact, imaging photoplethysmography uses photo-optical sensors to measure variations in light absorption, caused by blood volume pulsations, to assess cardiopulmonary parameters including pulse rate, pulse rate variability, and respiration rate. Recently, researchers have studied the applications and methodology of imaging photoplethysmography. Basic research has examined some of the variables affecting data quality and accuracy of imaging photoplethysmography including signal processing, imager parameters (e.g. frame rate and resolution), lighting conditions, subject motion, and subject skin tone. This technology may be beneficial for long term or continuous monitoring where contact measurements may be harmful (e.g. skin sensitivities) or where imperceptible or unobtrusive measurements are desirable. Using previously validated signal processing methods, we examined the effects of imager-to-subject distance on one-minute, windowed estimates of pulse rate. High-resolution video of 22, stationary participants was collected using an enthusiast-grade, mirrorless, digital camera equipped with a fully-manual, super-telephoto lens at distances of 25, 50, and 100 meters with simultaneous contact measurements of electrocardiography, and fingertip photoplethysmography. By comparison, previous studies have usually been conducted with imager-to-subject distances of up to only a few meters. Mean absolute error for one-minute, windowed, pulse rate estimates (compared to those derived from gold-standard electrocardiography) were 2.0, 4.1, and 10.9 beats per minute at distances of 25, 50, and 100 meters, respectively. Long-range imaging presents several unique challenges among which include decreased, observed light reflectance and smaller regions of interest. Nevertheless, these results demonstrate that accurate pulse rate measurements can be obtained from over long imager-to-participant distances given these constraints.

  7. Diagnostic performance of coronary computed tomography angiography versus exercise electrocardiography for coronary artery disease: a systematic review and meta-analysis.

    PubMed

    Yin, Xinxin; Wang, Jiali; Zheng, Wen; Ma, Jingjing; Hao, Panpan; Chen, Yuguo

    2016-07-01

    Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95-0.99] and 0.66 (95% CIs: 0.59-0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81-0.87) and 0.75 (95% CIs: 0.71-0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07-346.55) and 6.28 (95% CIs: 2.06-19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks' test showed no potential publication bias (P=0.17). CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD.

  8. Emergency department triage strategies for acute chest pain using creatine kinase-MB and troponin I assays: a cost-effectiveness analysis.

    PubMed

    Polanczyk, C A; Kuntz, K M; Sacks, D B; Johnson, P A; Lee, T H

    1999-12-21

    Evaluation of acute chest pain is highly variable. To evaluate the cost-effectiveness of strategies using cardiac markers and noninvasive tests for myocardial ischemia. Cost-effectiveness analysis. Prospective data from 1066 patients with chest pain and from the published literature. Patients admitted with acute chest pain. Lifetime. Societal. Creatine kinase (CK)-MB mass assay alone; CK-MB mass assay followed by cardiac troponin I assay if the CK-MB value is normal; CK-MB mass assay followed by troponin I assay if the CK-MB value is normal and electrocardiography shows ischemic changes; both CK-MB mass and troponin I assays; and troponin I assay alone. These strategies were evaluated alone or in combination with early exercise testing. Lifetime cost, life expectancy (in years), and incremental cost-effectiveness. For patients 55 to 64 years of age, measurement of CK-MB mass followed by exercise testing in appropriate patients was the most competitive strategy ($43000 per year of life saved). Measurement of CK-MB mass followed by troponin I measurement had an incremental cost-effectiveness ratio of $47400 per year of life saved for patients 65 to 74 years of age; it was also the most cost-effective strategy when early exercise testing could not be performed, CK-MB values were normal, and ischemic changes were seen on electrocardiography. Results were influenced by age, probability of myocardial infarction, and medical costs. Measurement of CK-MB mass plus early exercise testing is a cost-effective initial strategy for younger patients and those with a low to moderate probability of myocardial infarction. Troponin I measurement can be a cost-effective second test in higher-risk subsets of patients if the CK-MB level is normal and early exercise testing is not an option.

  9. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI.

    PubMed

    Zhang, Wei; Bogale, Saivivek; Golriz, Farahnaz; Krishnamurthy, Rajesh

    2017-11-01

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole.

  10. Syncope Best Practices: A Syncope Clinical Practice Guideline to Improve Quality.

    PubMed

    Phelps, Heather M; Sachdeva, Ritu; Mahle, William T; McCracken, Courtney E; Kelleman, Michael; McConnell, Michael; Fischbach, Peter S; Cardis, Brian M; Campbell, Robert M; Oster, Matthew E

    2016-05-01

    To determine whether implementation of a standardized clinical practice guideline (CPG) for the evaluation of syncope would decrease practice variability and resource utilization. A retrospective review of medical records of patients presenting to our practice for outpatient evaluation of syncope before and after implementation of the CPG. The guideline included elements of history, physical exam, electrocardiogram, and "red flags" for further testing. Outpatient pediatric cardiology offices of a large pediatric cardiology practice. All new patients between 3 and 21 years old, who presented to cardiology clinic with a chief complaint of syncope. The CPG for the evaluation of pediatric syncope was presented to the providers. Resource utilization was determined by the tests ordered by individual physicians before and after initiation of the CPG. Patient final diagnoses were recorded and the medical records were subsequently reviewed to determine if any patients, who presented again to the system, were ultimately diagnosed with cardiac disease. Of the 1496 patients with an initial visit for syncope, there was no significant difference in the diagnosis of cardiac disease before or after initiation of the CPG: (0.6% vs. 0.4%, P = .55). Electrocardiography provides the highest yield in the evaluation of pediatric syncope. Despite high compliance (86.9%), there were no overall changes in costs ($346.31 vs. $348.53, P = .85) or in resource utilization. There was, however, a decrease in the variability of ordering of echocardiograms among physicians, particularly among those at the extremes of utilization. Although the CPG did not decrease already low costs, it did decrease the wide variability in echo utilization. Evaluation beyond detailed history, physical exam, and electrocardiography provides no additional benefit in the evaluations of pediatric patients presenting with syncope. © 2015 Wiley Periodicals, Inc.

  11. Value of the Electrocardiogram as a Predictor of Right Ventricular Dysfunction in Patients With Chronic Right Ventricular Volume Overload.

    PubMed

    Alonso, Pau; Andrés, Ana; Rueda, Joaquín; Buendía, Francisco; Igual, Begoña; Rodríguez, María; Osa, Ana; Arnau, Miguel A; Salvador, Antonio

    2015-05-01

    Pulmonary regurgitation is a common complication in patients with repaired tetralogy of Fallot or congenital pulmonary stenosis. Electrocardiographic variables have been correlated with parameters used to evaluate right ventricular function. We aimed to analyze the diagnostic value of the width and fragmentation of the electrocardiogram in the identification of patients with right ventricular dysfunction and/or dilation. We selected 107 consecutive patients diagnosed with severe pulmonary insufficiency after repair of pulmonary stenosis or tetralogy of Fallot. The tests included electrocardiography, echocardiography, and magnetic resonance. Each electrocardiogram was analyzed manually to measure QRS duration. We defined QRS fragmentation as the presence of low-voltage waves in the terminal portion of the QRS complex in at least 2 contiguous leads. We found a significant negative correlation between QRS width and right ventricular function, as well as a positive correlation with right ventricular volume. The receiver operating characteristic curve indicated a cut-off point for QRS width of 140ms, which showed good sensitivity for a diagnosis of right ventricular dilation (> 80%) and dysfunction (> 95%). In logistic regression models, a QRS duration > 140ms was found to be the only independent predictor of right ventricular dilation and dysfunction. Electrocardiography is a rapid, widely available, and reproducible tool. QRS width constitutes an independent predictor of the presence of right ventricular dilation and dysfunction. This study is the first to provide a cutoff value for QRS width to screen for right ventricle involvement. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Predictive value of preoperative electrocardiography for perioperative cardiovascular outcomes in patients undergoing noncardiac, nonvascular surgery.

    PubMed

    Biteker, Murat; Duman, Dursun; Tekkeşin, Ahmet Ilker

    2012-08-01

    The utility of routine preoperative electrocardiography (ECG) for assessing perioperative cardiovascular risk in patients undergoing noncardiac, nonvascular surgery (NCNVS) is unclear. There would be an association between preoperative ECG and perioperative cardiovascular outcomes in patients undergoing NCNVS. A total of 660 patients undergoing NCNVS were prospectively evaluated. Patients age >18 years who underwent an elective, nonday case, open surgical procedure were enrolled. Troponin I concentrations and 12-lead ECG were evaluated the day before surgery, immediately after surgery, and on the first 5 postoperative days. Preoperative ECG showing atrial fibrillation, left or right bundle branch block, left ventricular hypertrophy, frequent premature ventricular complexes, pacemaker rhythm, Q-wave, ST-segment changes, or sinus tachycardia or bradycardia were classified as abnormal. The patients were followed up during hospitalization and were evaluated for the presence of perioperative cardiovascular events (PCE). Eighty patients (12.1%) experienced PCE. Patients with abnormal ECG findings had a greater incidence of PCE than those with normal ECG results (16% vs 6.4%; P < 0.001). Mean QTc interval was significantly longer in the patients who had PCE (436.6 ± 31.4 vs 413.3 ± 16.7 ms; P < 0.001). Univariate analysis showed a significant association between preoperative atrial fibrillation, pacemaker rhythm, ST-segment changes, QTc prolongation, and in-hospital PCE. However, only QTc prolongation (odds ratio: 1.15, 95% confidence interval: 1.06-1.2, P < 0.001) was an independent predictor of PCE according to the multivariate analysis. Every 10-ms increase in QTc interval was related to a 13% increase for PCE. Prolongation of the QTc interval on the preoperative ECG was related with PCE in patients undergoing NCNVS. © 2011 Wiley Periodicals, Inc.

  13. Investigation of mindin levels in hypertensive patients with left ventricular hypertrophy and QRS fragmentation on electrocardiography.

    PubMed

    Doğan, Tolga; Yetim, Mucahit; Çelik, Oğuzhan; Kalçık, Macit; Özcan, Oğuzhan; Doğan, İbrahim; Erenler, Ali Kemal; Bekar, Lütfü; Karavelioğlu, Yusuf

    2017-12-21

    Mindin was associated with diabetic nephropathy, podocyte injury, colitis, allergic asthma, liver ischaemia and reperpusion injury and ischaemic brain injury. On the other hand, it was reported as a protective factor against obesity, cardiac hypertrophy, fibrosis and remodelling. Fragmented QRS complexes (fQRS) are markers of altered ventricular depolarisation owing to a prior myocardial scar and fibrosis. In this study, we aimed to investigate mindin levels in hypertensive patients with left ventricular hypertrophy and fQRS on electrocardiography. This observational case-control study enrolled 70 (36 female) hypertensive patients with fQRS and 38 (23 female) hypertensive control patients. All patients were evaluated by transthoracic echocardiography. Mindin levels were measured by the enzyme-linked immunosorbent assay (ELISA). Clinical, echocardiographic and laboratory data were compared between patient and control groups. There was no significant difference between patient and control groups in terms of clinical, echocardiographic and routine laboratory parameters. The mindin levels were significantly higher in the patient group than controls (11.3 (7.21-19.31) vs 4.15 (2.86-6.34); p < .001). Multiple logistic regression analyses defined increased mindin levels as an independent predictor for the presence of fQRS (Odds ratio: 1.733; p = .034). Mindin levels >6.74 predicted the presence of fQRS with a sensitifity of 84.3% and specificity of 79.9% on receiver operating characteristic (ROC) curve analysis (The area under the curve:0.889; Confidence Interval: 0.827-0.951; p < .001). Mindin expressin is upregulated in hypertensive patients with fQRS complexes. In contrary to previous studies, increased mindin levels may be associated with myocardial fibrosis.

  14. Cost-effectiveness of coronary artery disease screening in asymptomatic patients with type 2 diabetes and other atherogenic risk factors in Japan: factors influencing on international application of evidence-based guidelines.

    PubMed

    Hayashino, Yasuaki; Shimbo, Takuro; Tsujii, Satoru; Ishii, Hitoshi; Kondo, Hirokazu; Nakamura, Tsukasa; Nagata-Kobayashi, Shizuko; Fukui, Tsuguya

    2007-05-16

    Screening for coronary artery disease (CAD) in asymptomatic diabetic patients with atherogenic risk factors is recommended by the American College of Cardiology/American Diabetes Association. It is not clear whether these guidelines apply to the Japanese population with a different epidemiology of CAD. This study evaluates the applicability of the U.S. guidelines to Japan, taking account of cost-effectiveness. A cost-effectiveness analysis using a Markov model was performed to measure the clinical benefit and cost of CAD screening in asymptomatic patients with diabetes and additional atherogenic risk factors. We evaluated cohorts of patients stratified by age, gender, and atherogenic risks. The incremental cost-effectiveness of not screening, exercise electrocardiography, exercise echocardiography, and exercise single-photon emission-tomography (SPECT) was calculated. The data used were obtained from the literature. Outcomes are expressed as US dollars per quality-adjusted life year (QALY). Compared with not screening, the incremental cost-effectiveness ratio (ICER) of exercise electrocardiography was $31,400/QALY for 60-year-old asymptomatic diabetic men, and 46,600 for 65-year-old women with hypertension and smoking. The ICER of exercise echocardiography was $31,500/QALY and of SPECT was $326,000/QALY, compared with the next dominant strategy. Sensitivity analyses found that these results varied according to age, gender, the combination of additional atherogenic risk factors, and the frequency of screening. From a societal perspective the U.S. guidelines on screening for CAD in high risk diabetic patients are applicable to the Japanese population. However, the population subjected to screening should be carefully selected to obtain greatest benefit from screening.

  15. Association of Implementation of Practice Standards for Electrocardiographic Monitoring With Nurses' Knowledge, Quality of Care, and Patient Outcomes: Findings From the Practical Use of the Latest Standards of Electrocardiography (PULSE) Trial.

    PubMed

    Funk, Marjorie; Fennie, Kristopher P; Stephens, Kimberly E; May, Jeanine L; Winkler, Catherine G; Drew, Barbara J

    2017-02-01

    Although continuous electrocardiographic (ECG) monitoring is ubiquitous in hospitals, monitoring practices are inconsistent. We evaluated implementation of American Heart Association practice standards for ECG monitoring on nurses' knowledge, quality of care, and patient outcomes. The PULSE (Practical Use of the Latest Standards of Electrocardiography) Trial was a 6-year multisite randomized clinical trial with crossover that took place in 65 cardiac units in 17 hospitals. We measured outcomes at baseline, time 2 after group 1 hospitals received the intervention, and time 3 after group 2 hospitals received the intervention. Measurement periods were 15 months apart. The 2-part intervention consisted of an online ECG monitoring education program and strategies to implement and sustain change in practice. Nurses' knowledge (N=3013 nurses) was measured by a validated 20-item online test, quality of care related to ECG monitoring (N=4587 patients) by on-site observation, and patient outcomes (mortality, in-hospital myocardial infarction, and not surviving a cardiac arrest; N=95 884 hospital admissions) by review of administrative, laboratory, and medical record data. Nurses' knowledge improved significantly immediately after the intervention in both groups but was not sustained 15 months later. For most measures of quality of care (accurate electrode placement, accurate rhythm interpretation, appropriate monitoring, and ST-segment monitoring when indicated), the intervention was associated with significant improvement, which was sustained 15 months later. Of the 3 patient outcomes, only in-hospital myocardial infarction declined significantly after the intervention and was sustained. Online ECG monitoring education and strategies to change practice can lead to improved nurses' knowledge, quality of care, and patient outcomes. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01269736. © 2017 American Heart Association, Inc.

  16. The relationship between patient data and pooled clinical management decisions.

    PubMed

    Ludbrook, G I; O'Loughlin, E J; Corcoran, T B; Grant, C

    2013-01-01

    A strong relationship between patient data and preoperative clinical decisions could potentially be used to support clinical decisions in preoperative management. The aim of this exploratory study was to determine the relationship between key patient data and pooled clinical opinions on management. In a previous study, panels of anaesthetists compared the quality of computer-assisted patient health assessments with outpatient consultations and made decisions on the need for preoperative tests, no preoperative outpatient assessment, possible postoperative intensive care unit/high dependency unit requirements and aspiration prophylaxis. In the current study, the relationship between patient data and these decisions was examined using binomial logistic regression analysis. Backward stepwise regression was used to identify independent predictors of each decision (at P >0.15), which were then incorporated into a predictive model. The number of factors related to each decision varied: blood picture (four factors), biochemistry (six factors), coagulation studies (three factors), electrocardiography (eight factors), chest X-ray (seven factors), preoperative outpatient assessment (17 factors), intensive care unit requirement (eight factors) and aspiration prophylaxis (one factor). The factor types also varied, but included surgical complexity, age, gender, number of medications or comorbidities, body mass index, hypertension, central nervous system condition, heart disease, sleep apnoea, smoking, persistent pain and stroke. Models based on these relationships usually demonstrated good sensitivity and specificity, with receiver operating characteristics in the following areas under curve: blood picture (0.75), biochemistry (0.86), coagulation studies (0.71), electrocardiography (0.90), chest X-ray (0.85), outpatient assessment (0.85), postoperative intensive care unit requirement (0.88) and aspiration prophylaxis (0.85). These initial results suggest modelling of patient data may have utility supporting clinicians' preoperative decisions.

  17. Utility of electrocardiogram in the assessment and monitoring of pulmonary hypertension (idiopathic or secondary to pulmonary developmental abnormalities) in patients≤18 years of age.

    PubMed

    Lau, Kelvin C; Frank, David B; Hanna, Brian D; Patel, Akash R

    2014-07-15

    Electrocardiograms have utility in disease stratification and monitoring in adult pulmonary arterial hypertension (PAH). We examined the electrocardiographic findings that are common in pediatric PAH and assessed for correlation with disease severity and progression. We retrospectively identified patients aged≤18 years followed at a single institution from January 2001 to June 2012 with catheterization-confirmed diagnosis of idiopathic PAH and PAH secondary to pulmonary developmental abnormalities. Patients with an electrocardiography performed within 60 days of catheterization were included. Primary and secondary outcomes are the prevalence of abnormal electrocardiographic findings at the time of catheterization and the association between electrocardiographic and hemodynamic findings and electrocardiographic changes with disease progression on follow-up catheterization, respectively. Of the 100 electrocardiography-catheterization pairs derived from the 46 patients identified, 93% had an electrocardiographic abnormality: 78% had right ventricular hypertrophy (RVH) and 52% had right axis deviation (RAD) for age. In patients with idiopathic PAH, the presence of RVH and RAD correlated with pulmonary vascular resistance and transpulmonary gradient. RAD and RVH on baseline electrocardiogram was associated with an increased risk of disease progression on subsequent catheterization (odds ratio 11.0, 95% confidence interval 1.3 to 96.2, p=0.03) after adjusting for PAH subgroup. The sensitivity, specificity, and positive and negative predictive values of RAD and RVH on baseline electrocardiogram for disease progression were 92%, 48%, 33%, and 95%, respectively. In conclusion, electrocardiographic abnormalities are common in pediatric PAH. RAD and RVH on electrocardiogram were associated with worse hemodynamics, whereas their absence is suggestive of a lack of disease progression. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. The Value of the Electrocardiogram for Evaluating Prognosis in Patients with Idiopathic Pulmonary Arterial Hypertension.

    PubMed

    Cheng, Xiao-Ling; He, Jian-Guo; Liu, Zhi-Hong; Gu, Qing; Ni, Xin-Hai; Zhao, Zhi-Hui; Luo, Qin; Xiong, Chang-Ming

    2017-02-01

    Association between electrocardiography (ECG) features and right ventricular anatomy and physiology has been established. This study is aimed to identify the value of 12-lead ECG in evaluating prognosis of patients with idiopathic pulmonary arterial hypertension (IPAH). 194 patients with newly diagnosed IPAH were included in this study. Correlations between electrocardiography variables and hemodynamics were assessed. Univariate and multivariable cox regression analysis were performed to identify ECG variables for predicting all-cause mortality in IPAH. Partial correlation analysis showed that P wave amplitude in lead II correlated with the mean pulmonary arterial pressure (mPAP, r = 0.349, p ≤ 0.001) and cardiac index (CI, r = -0.224, p = 0.002); R wave amplitude in V1 correlated with mPAP (r = 0.359, p ≤ 0.001); S wave amplitude in V6 correlated with mPAP (r = 0.259, p = 0.030) and CI (r = -0.220, p = 0.003). P wave amplitude in lead II (HR 1.555, p = 0.033) and R wave amplitude in lead aVR (HR 5.058, p < 0.001) were the independent predictors of all-cause mortality. Kaplan-Meier survival curves showed patients with a p ≥ 0.25 mv in lead II, and R ≥ 0.4 mv in lead aVR had lower 3-year survival (55 vs. 91%, p < 0.001). Specific lead-12 ECG features could reflect right ventricular overload hemodynamics, and are useful to evaluate prognosis of patients with IPAH.

  19. Clinical Characteristics and Prognosis of End-stage Hypertrophic Cardiomyopathy.

    PubMed

    Xiao, Yan; Yang, Kun-Qi; Yang, Yan-Kun; Liu, Ya-Xin; Tian, Tao; Song, Lei; Jiang, Xiong-Jing; Zhou, Xian-Liang

    2015-06-05

    End-stage hypertrophic cardiomyopathy (HCM) is complicated by substantial adverse events. However, few studies have focused on electrocardiographic features and their prognostic values in HCM. This study aimed to evaluate the clinical manifestations and prognostic value of electrocardiography in patients with end-stage HCM. End-stage HCM patients were enrolled from a total of 1844 consecutive HCM patients from April 2002 to November 2013 at Fuwai Hospital. Clinical data, including medical history, electrocardiography, and echocardiography, were analyzed. Cox hazards regression analysis was used to assess the risk factors for cardiovascular mortality. End-stage HCM was identified in 99 (5.4%) patients, averaged at 52 ± 16 years old at entry. Atrial fibrillation was observed in 53 patients and mural thrombus in 19 patients. During 3.9 ± 3.0 years of follow-up, embolic stroke, refractory heart failure, and death or transplantation were observed in 20, 39, and 51 patients, respectively. The incidence of annual mortality was 13.2%. Multivariate Cox hazards regression analysis identified New York Heart Association Class (NYHA) III/IV at entry (hazard ratio [HR]: 1.99; 95% confidence interval [CI]: 1.05-3.80; P = 0.036), left bundle branch block (LBBB) (HR: 2.80; 95% CI: 1.47-5.31; P = 0.002), and an abnormal Q wave (HR: 2.21; 95% CI: 1.16-4.23; P = 0.016) as independent predictors of cardiovascular death, in accordance with all-cause death and heart failure-related death. LBBB and an abnormal Q wave are risk factors of cardiovascular mortality in end-stage HCM and provide new evidence for early intervention. Susceptibility of end-stage HCM patients to mural thrombus and embolic events warrants further attention.

  20. Carbon monoxide poisoning-induced cardiomyopathy from charcoal at a barbecue restaurant: a case report.

    PubMed

    Kim, Hyun-Jun; Chung, Yun Kyung; Kwak, Kyeong Min; Ahn, Se-Jin; Kim, Yong-Hyun; Ju, Young-Su; Kwon, Young-Jun; Kim, Eun-A

    2015-01-01

    Acute carbon monoxide poisoning has important clinical value because it can cause severe adverse cardiovascular effects and sudden death. Acute carbon monoxide poisoning due to charcoal is well reported worldwide, and increased use of charcoal in the restaurant industry raises concern for an increase in occupational health problems. We present a case of carbon monoxide poisoning induced cardiomyopathy in a 47-year-old restaurant worker. A male patient was brought to the emergency department to syncope and complained of left chest pain. Cardiac angiography and electrocardiography were performed to rule out acute ischemic heart disease, and cardiac markers were checked. After relief of the symptoms and stabilization of the cardiac markers, the patient was discharged without any complications. Electrocardiography was normal, but cardiac angiography showed up to a 40% midsegmental stenosis of the right coronary artery with thrombotic plaque. The level of cardiac markers was elevated at least 5 to 10 times higher than the normal value, and the carboxyhemoglobin concentration was 35% measured at one hour after syncope. Following the diagnosis of acute carbon monoxide poisoning induced cardiomyopathy, the patient's medical history and work exposure history were examined. He was found to have been exposed to burning charcoal constantly during his work hours. Severe exposure to carbon monoxide was evident in the patient because of high carboxyhemoglobin concentration and highly elevated cardiac enzymes. We concluded that this exposure led to subsequent cardiac injury. He was diagnosed with acute carbon monoxide poisoning-induced cardiomyopathy due to an unsafe working environment. According to the results, the risk of exposure to noxious chemicals such as carbon monoxide by workers in the food service industry is potentially high, and workers in this sector should be educated and monitored by the occupational health service to prevent adverse effects.

  1. Prognostic value of computed tomographic coronary angiography and exercise electrocardiography for cardiovascular events

    PubMed Central

    Kim, Kye-Hwan; Jeon, Kyung Nyeo; Kang, Min Gyu; Ahn, Jong Hwa; Koh, Jin-Sin; Park, Yongwhi; Hwang, Seok-Jae; Jeong, Young-Hoon; Kwak, Choong Hwan; Hwang, Jin-Yong; Park, Jeong Rang

    2016-01-01

    Background/Aims: This study is a head-to-head comparison of predictive values for long-term cardiovascular outcomes between exercise electrocardiography (ex-ECG) and computed tomography coronary angiography (CTCA) in patients with chest pain. Methods: Four hundred and forty-two patients (mean age, 56.1 years; men, 61.3%) who underwent both ex-ECG and CTCA for evaluation of chest pain were included. For ex-ECG parameters, the patients were classified according to negative or positive results, and Duke treadmill score (DTS). Coronary artery calcium score (CACS), presence of plaque, and coronary artery stenosis were evaluated as CTCA parameters. Cardiovascular events for prognostic evaluation were defined as unstable angina, acute myocardial infarction, revascularization, heart failure, and cardiac death. Results: The mean follow-up duration was 2.8 ± 1.1 years. Fifteen patients experienced cardiovascular events. Based on pretest probability, the low- and intermediate-risks of coronary artery disease were 94.6%. Odds ratio of CACS > 40, presence of plaque, coronary stenosis ≥ 50% and DTS ≤ 4 were significant (3.79, p = 0.012; 9.54, p = 0.030; 6.99, p < 0.001; and 4.58, p = 0.008, respectively). In the Cox regression model, coronary stenosis ≥ 50% (hazard ratio, 7.426; 95% confidence interval, 2.685 to 20.525) was only significant. After adding DTS ≤ 4 to coronary stenosis ≥ 50%, the integrated discrimination improvement and net reclassification improvement analyses did not show significant. Conclusions: CTCA was better than ex-ECG in terms of predicting long-term outcomes in low- to intermediate-risk populations. The predictive value of the combination of CTCA and ex-ECG was not superior to that of CTCA alone. PMID:27017387

  2. Variation in the Use of 12‐Lead Electrocardiography for Patients With Chest Pain by Emergency Medical Services in North Carolina

    PubMed Central

    Bush, Montika; Glickman, Lawrence T.; Fernandez, Antonio R.; Garvey, J. L.; Glickman, Seth W.

    2013-01-01

    Background Prehospital 12‐lead electrocardiography (ECG) is critical to timely STEMI care although its use remains inconsistent. Previous studies to identify reasons for failure to obtain a prehospital ECG have generally only focused on individual emergency medical service (EMS) systems in urban areas. Our study objective was to identify patient, geographic, and EMS agency‐related factors associated with failure to perform a prehospital ECG across a statewide geography. Methods and Results We analyzed data from the Prehospital Medical Information System (PreMIS) in North Carolina from January 2008 to November 2010 for patients >30 years of age who used EMS and had a prehospital chief complaint of chest pain. Among 3.1 million EMS encounters, 134 350 patients met study criteria. From 2008–2010, 82 311 (61%) persons with chest pain received a prehospital ECG; utilization increased from 55% in 2008 to 65% in 2010 (trend P<0.001). Utilization by health referral region ranged from 22.9% to 74.2% and was lowest in rural areas. Men were more likely than women to have an ECG performed (63.0% vs 61.3%, adjusted RR 1.02, 95% CI 1.01 to 1.04). The certification‐level of the EMS provider (paramedic vsbasic/intermediate) and system‐level ECG equipment availability were the strongest predictors of ECG utilization. Persons in an ambulance with a certified paramedic were significantly more likely to receive a prehospital ECG than nonparamedics (RR 2.15, 95% CI 1.55, 2.99). Conclusions Across a large geographic area prehospital ECG use increased significantly, although important quality improvement opportunities remain. Increasing ECG availability and improving EMS certification and training levels are needed to improve overall care and reduce rural‐urban treatment differences. PMID:23920232

  3. Effects of manual lymph drainage on cardiac autonomic tone in healthy subjects.

    PubMed

    Kim, Sung-Joong; Kwon, Oh-Yun; Yi, Chung-Hwi

    2009-01-01

    This study was designed to investigate the effects of manual lymph drainage on the cardiac autonomic tone. Thirty-two healthy male subjects were randomly assigned to manual lymph drainage (MLD) (experimental) and rest (control) groups. Electrocardiogram (ECG) parameters were recorded with bipolar electrocardiography using standard limb lead positions. The pressure-pain threshold (PPT) was quantitatively measured using an algometer. Heart rate variability differed significantly between the experimental and control groups (p < 0.05), but the PPT in the upper trapezius muscle did not (p > 0.05). These findings indicate that the application of MLD was effective in reducing the activity of the sympathetic nervous system.

  4. Studies into Equine Electrocardiography and Vectorcardiography

    PubMed Central

    Holmes, J. R.; Alps, B. J.

    1967-01-01

    Theoretical consideration has been given in two horses to the properties of the electric field created by the equine heart acting as a simple electric generator. The principles of the vectorial theory have been applied to test the validity of application of the dipole concept. The cardiac electric forces, althrough complex in the immediate region of the heart, appear at the body surface in a similar form to those arising from a relatively immobile, single equivalent dipole. The potential value of the technique of vectorcardiography in cardiological investigations is briefly discussed. ImagesFig. 1.Fig. 3.Fig. 5.Fig. 10.Fig. 12.Fig. 13. PMID:17649586

  5. The application of biomedical engineering techniques to the diagnosis and management of tropical diseases: a review.

    PubMed

    Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Faisal, Tarig; Neuman, Michael

    2015-03-23

    This paper reviews a number of biomedical engineering approaches to help aid in the detection and treatment of tropical diseases such as dengue, malaria, cholera, schistosomiasis, lymphatic filariasis, ebola, leprosy, leishmaniasis, and American trypanosomiasis (Chagas). Many different forms of non-invasive approaches such as ultrasound, echocardiography and electrocardiography, bioelectrical impedance, optical detection, simplified and rapid serological tests such as lab-on-chip and micro-/nano-fluidic platforms and medical support systems such as artificial intelligence clinical support systems are discussed. The paper also reviewed the novel clinical diagnosis and management systems using artificial intelligence and bioelectrical impedance techniques for dengue clinical applications.

  6. [Specific features of the functional state of the cardiorespiratory system in athletes differing in the types of muscular activity during the preparatory period of the training cycle].

    PubMed

    Ivanova, N B

    2011-01-01

    The present study of the functional state of the cadiorespiratory system included athletes engaged in cyclic team sports. The state of the cardiorespiratory system was estimated from the measurement of central hemodynamics and cardiac rhythm variability, results of electrocardiography, spirography, and pneumotachography performed during the preparatory period for the training cycle. It was shown that the cardiovascular and respiratory systems as well as vegetative regulation of the cardiac rhythm of the athletes under examination underwent differently directed structural modification depending on the specific patterns of muscular activity.

  7. The Child as a Surrogate for Diagnosis of Lupus in the Mother.

    PubMed

    Adelowo, Olufemi O; Ohagwu, Kenneth A; Aigbokhan, Ejiehi E; Akintayo, Richard O

    2017-01-01

    Introduction. Neonatal lupus erythematosus (NLE) is an acquired disease of the newborn caused by transplacental transfer of maternal anti-Ro/SSA, anti-La/SSB, and infrequently anti-U1 RNP antibodies. Methodology. This is a case report of a male infant delivered via Caesarean section at 36-week gestation following detection of fetal bradycardia during routine antenatal clinic visit. Results. The mother was seropositive for antinuclear antibody (ANA) and anti-Ro/SSA and had elevated erythrocyte sedimentation rate. The baby was positive for ANA, extractable nuclear antigen (ENA), and anti-Ro/SSA. Pediatric echocardiography was abnormal and electrocardiography confirmed complete heart block.

  8. Increase in Cardiac Troponin I in a Lamb with Tetralogy of Fallot

    PubMed Central

    NEUWALD, Elisa Barp; SOARES, Frederico Aécio Carvalho; DREYER, Cristina Terres; CARNESELLA, Samuel; WOUTERS, Angelica Terezinha Barth; GONZÁLEZ, Félix Hilario Diaz; DRIEMEIER, David

    2013-01-01

    ABSTRACT This study describes a case of tetralogy of Fallot in a lamb showing failure to thrive and signs of respiratory distress. Physical examination, electrocardiography, thoracic radiographies, echocardiography and cardiac troponin I evaluation were performed. The value of cardiac troponin I was compared with the values of 10 healthy lambs of the same age and breed, and the affected animal demonstrated an increase in cardiac troponin I. Due to the poor prognosis, euthanasia was indicated, and necropsy confirmed the diagnosis. This is the first report of an increase in cardiac troponin I in a lamb with tetralogy of Fallot. PMID:23685750

  9. Ethical and legal issues in donation after cardiac death in Italy.

    PubMed

    Bruzzone, P

    2010-05-01

    In Italy death of a human being must be declared either after brain death or after 20 minutes of cardiac arrest, certified by continuous electrocardiography (EKG) recording. It is my personal opinion that in such circumstances after cardiac death (DCD) will allow at best only the retrieval of few marginal kidneys and some tissues, and therefore will not be very helpful for our waiting list patients. I suggest instead modifying first the Italian law in order to be able to declare cardiac death after only 5 minutes of cardiac arrest, certified by continuous EKG recording. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  10. Predictors of Cardiovascular Events After Liver Transplantation.

    PubMed

    Gallegos-Orozco, Juan F; Charlton, Michael R

    2017-05-01

    Indications for liver transplant have been extended, and older and sicker patients are undergoing transplantation. Infectious, malignant, and cardiovascular diseases account for the most posttransplant deaths. Cirrhotic patients can develop heart disease through systemic diseases affecting the heart and the liver, cirrhosis-specific heart disease, or common cardiovascular. No single factor can predict posttransplant cardiovascular complications. Patients with history of cardiovascular disease, and specific abnormalities on echocardiography, electrocardiography, or serum markers of heart disease seem to be at increased risk of complications. Pretransplant cardiovascular evaluation is essential to detecting these risk factors so their effects can be mitigated through appropriate intervention. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Direct patterning of organic conductors on knitted textiles for long-term electrocardiography

    NASA Astrophysics Data System (ADS)

    Takamatsu, Seiichi; Lonjaret, Thomas; Crisp, Dakota; Badier, Jean-Michel; Malliaras, George G.; Ismailova, Esma

    2015-10-01

    Wearable sensors are receiving a great deal of attention as they offer the potential to become a key technological tool for healthcare. In order for this potential to come to fruition, new electroactive materials endowing high performance need to be integrated with textiles. Here we present a simple and reliable technique that allows the patterning of conducting polymers on textiles. Electrodes fabricated using this technique showed a low impedance contact with human skin, were able to record high quality electrocardiograms at rest, and determine heart rate even when the wearer was in motion. This work paves the way towards imperceptible electrophysiology sensors for human health monitoring.

  12. A blended learning program on undergraduate nursing students' learning of electrocardiography.

    PubMed

    Jang, Keum-Seong; Kim, Yun-Min; Park, Soon-Joo

    2006-01-01

    This study sought to evaluate the feasibility of applying the blended learning program that combines the advantages of face-to-face(FTF) learning and e-learning. The blended learning program was developed by the authors and implemented for 4 weeks. 56 senior nursing students were recruited at a university in Korea. Significant improvement was noted in learning achievement. No significant differences were noted between FTF and web-based learning in learning motivation. Learning satisfaction and students' experience in taking this course revealed some positive effects of blended learning. The use of blended learning program for undergraduate nursing students will provide an effective learning model.

  13. The Normal Electrocardiogram: Resting 12-Lead and Electrocardiogram Monitoring in the Hospital.

    PubMed

    Harris, Patricia R E

    2016-09-01

    The electrocardiogram (ECG) is a well-established diagnostic tool extensively used in clinical settings. Knowledge of cardiac rhythm and mastery of cardiac waveform interpretation are fundamental for intensive care nurses. Recognition of the normal findings for the 12-lead ECG and understanding the significance of changes from baseline in continuous cardiac monitoring are essential steps toward ensuring safe patient care. This article highlights historical developments in electrocardiography, describes the normal resting 12-lead ECG, and discusses the need for continuous cardiac monitoring. In addition, future directions for the ECG are explored briefly. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Incremental value of contrast echocardiography in the evaluation of a cardiac thrombus.

    PubMed

    Po, Jose Ricardo F; Tong, Matthew S; Grove, Erica L; Biederman, Robert W W

    2017-02-01

    A 52-year-old man presented with altered mental status and report of prior complaint of chest pain. On electrocardiography, anterolateral ST-segment elevations with Q-waves in the septal leads were seen. Initial echocardiography images demonstrated a thickened anteroseptum. Further imaging showed the presence of a well-attached laminated apical thrombus. Contrast echocardiography images showed that the thrombus had minimal attachment to the endocardial surface. CT head subsequently showed the presence of acute stroke. The case demonstrates the additional value of contrast echocardiography in the evaluation of cardiac masses despite the certainty in the diagnosis of a thrombus. © 2017, Wiley Periodicals, Inc.

  15. [The effect of hypothyroidism on cardiac function in dogs].

    PubMed

    Stephan, I; Nolte, I; Hoppen, H O

    2003-06-01

    The thyroid hormones have direct and indirect effects on the heart. So it is possible that depression of left ventricular function is associated with hypothyroidism. This publication describes cardiac findings (auscultation, electrocardiography, echocardiography) in ten hypothyroid dogs. Low heart rates, reduced R-amplitudes and bradycardic arrhythmias (first and second-degree AV block) were found on the electrocardiogram before treatment. On the echocardiograms most of the dogs showed reduced contractillity and reduced left ventricular wall thickness. Seven dogs were reexamined after levothyroxine supplementation. Effects of treatment were increased heart rates and R-amplitudes as well as disappearance of the bradycardic arrhythmias in electrocardiographic examination. The echocardiographic examination showed increased contractility and increased left ventricular wall thickness.

  16. A Dog with Pseudo-Addison Disease Associated with Trichuris vulpis Infection.

    PubMed

    Venco, Luigi; Valenti, Valentina; Genchi, Marco; Grandi, Giulio

    2011-01-01

    A female Rottweiler dog was presented with a history of intermittent vomiting and diarrhoea, dysorexia, weakness, and weight loss. Haemocytometry and biochemistry values were within normal ranges except for electrolyte analyses, that demonstrated hyponatremia and hyperkalemia with a decreased sodium/potassium ratio. A diagnosis of hypoadrenocorticism was suspected. Basal and post-ACTH stimulation cortisolemia were within the normal values. Electrocardiography was normal, and thoracic radiography showed no significant modifications. On abdominal ultrasonography, adrenal glands appeared normal, while the bowel was distended, and several thin linear hyperechoic objects floating in the lumen were observed. Two adult female whipworms (Trichuris vulpis) were collected following bowel irrigation. Anthelmintic treatment against the parasite was curative.

  17. Comparison between artificial neural network and multilinear regression models in an evaluation of cognitive workload in a flight simulator.

    PubMed

    Hannula, Manne; Huttunen, Kerttu; Koskelo, Jukka; Laitinen, Tomi; Leino, Tuomo

    2008-01-01

    In this study, the performances of artificial neural network (ANN) analysis and multilinear regression (MLR) model-based estimation of heart rate were compared in an evaluation of individual cognitive workload. The data comprised electrocardiography (ECG) measurements and an evaluation of cognitive load that induces psychophysiological stress (PPS), collected from 14 interceptor fighter pilots during complex simulated F/A-18 Hornet air battles. In our data, the mean absolute error of the ANN estimate was 11.4 as a visual analog scale score, being 13-23% better than the mean absolute error of the MLR model in the estimation of cognitive workload.

  18. The Application of Biomedical Engineering Techniques to the Diagnosis and Management of Tropical Diseases: A Review

    PubMed Central

    Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Faisal, Tarig; Neuman, Michael

    2015-01-01

    This paper reviews a number of biomedical engineering approaches to help aid in the detection and treatment of tropical diseases such as dengue, malaria, cholera, schistosomiasis, lymphatic filariasis, ebola, leprosy, leishmaniasis, and American trypanosomiasis (Chagas). Many different forms of non-invasive approaches such as ultrasound, echocardiography and electrocardiography, bioelectrical impedance, optical detection, simplified and rapid serological tests such as lab-on-chip and micro-/nano-fluidic platforms and medical support systems such as artificial intelligence clinical support systems are discussed. The paper also reviewed the novel clinical diagnosis and management systems using artificial intelligence and bioelectrical impedance techniques for dengue clinical applications. PMID:25806872

  19. Contrast Media Delivery in the Assessment of Anomalous Left Coronary Artery From the Pulmonary Artery.

    PubMed

    Saade, Charbel; Al-Hamra, Salam; Al-Mohiy, Hussain; El-Merhi, Fadi

    2016-05-01

    A patient with a history of mitral valve prolapse and regurgitation that was corrected with a mitral ring repair 15 years earlier received a diagnosis of anomalous left coronary artery arising from the pulmonary artery and underwent repair. Coronary computed tomography angiography (CTA) was employed to image the patient before surgical intervention. Synchronizing contrast media administration to opacify the right coronary artery in the arterial phase and the left coronary artery in the venous phase required a test-bolus approach. Matching compromised cardiovascular dynamics with patient-specific contrast media administration protocols was improved considerably with the use of a test-bolus technique during electrocardiography-gated coronary CTA.

  20. Wet cupping therapy restores sympathovagal imbalances in cardiac rhythm.

    PubMed

    Arslan, Müzeyyen; Yeşilçam, Nesibe; Aydin, Duygu; Yüksel, Ramazan; Dane, Senol

    2014-04-01

    A recent study showed that cupping had therapeutic effects in rats with myocardial infarction and cardiac arrhythmias. The current studyaimed to investigate the possible useful effects of cupping therapy on cardiac rhythm in terms of heart rate variability (HRV). Forty healthy participants were included. Classic wet cupping therapy was applied on five points of the back. Recording electrocardiography (to determine HRV) was applied 1 hour before and 1 hour after cupping therapy. All HRV parameters increased after cupping therapy compared with before cupping therapy in healthy persons. These results indicate for the first time in humans that cupping might be cardioprotective. In this study, cupping therapy restored sympathovagal imbalances by stimulating the peripheral nervous system.

  1. The diagnostic accuracy of exercise electrocardiography - A review

    NASA Technical Reports Server (NTRS)

    Johnson, R. L.; Bungo, M. W.

    1983-01-01

    The cardiovascular 'stress test', and particularly the graded treadmill exercist test, has gained wide acceptance as a diagnostic aid in searching for ischemic heart disease and as a prognostic indicator for those with known coronary artery disease. Controversies still exist, however, in its use in mass screening and in interpreting equivocal tests. A review of the use and value of electrocardiographic exercise testing is presented. Topics such as its use in asymptomatic individuals, the adjuvant use of clinical examination, and the examination of ancillary treadmill parameters are presented. No attempt is made to detail the very significant contributions of radionuclide scanning. The positive exercise electrocardiogram in the asymptomatic subject is discussed and guidelines for clinical management are offered.

  2. Design intelligent wheelchair with ECG measurement and wireless transmission function.

    PubMed

    Chou, Hsi-Chiang; Wang, Yi-Ming; Chang, Huai-Yuan

    2015-01-01

    The phenomenon of aging populations has produced widespread health awareness and magnified the need for improved medical quality and technologies. Statistics show that ischemic heart disease is the leading cause of death for older people and people with reduced mobility; therefore, wheelchairs have become their primary means of transport. Hence, an arrhythmia-detecting smart wheelchair was proposed in this study to provide real-time electrocardiography (ECG)-monitoring to patients with heart disease and reduced mobility. A self-developed, handheld ECG-sensing instrument was integrated with a wheelchair and a lab-written, arrhythmia-detecting program. The measured ECG data were transmitted through a Wi-Fi module and analyzed and diagnosed using the human-machine interface.

  3. Stretchable Dry Electrodes with Concentric Ring Geometry for Enhancing Spatial Resolution in Electrophysiology.

    PubMed

    Wang, Kaiping; Parekh, Udit; Pailla, Tejaswy; Garudadri, Harinath; Gilja, Vikash; Ng, Tse Nga

    2017-10-01

    The multichannel concentric-ring electrodes are stencil printed on stretchable elastomers modified to improve adhesion to skin and minimize motion artifacts for electrophysiological recordings of electroencephalography, electromyography, and electrocardiography. These dry electrodes with a poly(3,4-ethylenedioxythiophene) polystyrene sulfonate interface layer are optimized to show lower noise level than that of commercial gel disc electrodes. The concentric ring geometry enables Laplacian filtering to pinpoint the bioelectric potential source with spatial resolution determined by the ring distance. This work shows a new fabrication approach to integrate and create designs that enhance spatial resolution for high-quality electrophysiology monitoring devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Assessment of heart rate variability based on mobile device for planning physical activity

    NASA Astrophysics Data System (ADS)

    Svirin, I. S.; Epishina, E. V.; Voronin, V. V.; Semenishchev, E. A.; Solodova, E. N.; Nabilskaya, N. V.

    2015-05-01

    In this paper we present a method for the functional analysis of human heart based on electrocardiography (ECG) signals. The approach using the apparatus of analytical and differential geometry and correlation and regression analysis. ECG contains information on the current condition of the cardiovascular system as well as on the pathological changes in the heart. Mathematical processing of the heart rate variability allows to obtain a great set of mathematical and statistical characteristics. These characteristics of the heart rate are used when solving research problems to study physiological changes that determine functional changes of an individual. The proposed method implemented for up-to-date mobile Android and iOS based devices.

  5. Routine clinical heart examinations using SQUID magnetocardiography at University of Tsukuba Hospital

    NASA Astrophysics Data System (ADS)

    Inaba, T.; Nakazawa, Y.; Yoshida, K.; Kato, Y.; Hattori, A.; Kimura, T.; Hoshi, T.; Ishizu, T.; Seo, Y.; Sato, A.; Sekiguchi, Y.; Nogami, A.; Watanabe, S.; Horigome, H.; Kawakami, Y.; Aonuma, K.

    2017-11-01

    A 64-channel Nb-based DC-SQUID magnetocardiography (MCG) system was installed at the University of Tsukuba Hospital (UTH) in March 2007 after obtaining Japanese pharmaceutical approval and insurance reimbursement approval. In the period between 2008 and 2016, the total number of patients was 10 085. The heart diseases diagnosed in fetuses as well as adults are mainly atrial arrhythmia, abnormal repolarization, ventricular arrhythmia, and fetal arrhythmia. In most cases of insufficient diagnostic accuracy with electrocardiography, SQUID MCG precisely revealed these heart diseases as an abnormal electrical current distribution. Based on success in routine examinations, SQUID MCG is now an indispensable clinical instrument with diagnostic software tuned up during routine use at UTH.

  6. Direct patterning of organic conductors on knitted textiles for long-term electrocardiography

    PubMed Central

    Takamatsu, Seiichi; Lonjaret, Thomas; Crisp, Dakota; Badier, Jean-Michel; Malliaras, George G.; Ismailova, Esma

    2015-01-01

    Wearable sensors are receiving a great deal of attention as they offer the potential to become a key technological tool for healthcare. In order for this potential to come to fruition, new electroactive materials endowing high performance need to be integrated with textiles. Here we present a simple and reliable technique that allows the patterning of conducting polymers on textiles. Electrodes fabricated using this technique showed a low impedance contact with human skin, were able to record high quality electrocardiograms at rest, and determine heart rate even when the wearer was in motion. This work paves the way towards imperceptible electrophysiology sensors for human health monitoring. PMID:26446346

  7. ECG Wave-Maven: An Internet-based Electrocardiography Self-Assessment Program for Students and Clinicians.

    PubMed

    McClennen, Seth; Nathanson, Larry A; Safran, Charles; Goldberger, Ary L

    2003-12-01

    To create a multimedia internet-based ECG teaching tool, with the ability to rapidly incorporate new clinical cases. We created ECG Wave-Maven ( http://ecg.bidmc.harvard.edu ), a novel teaching tool with a direct link to an institution-wide clinical repository. We analyzed usage data from the web between December, 2000 and May 2002. In 17 months, there have been 4105 distinct uses of the program. A majority of users are physicians or medical students (2605, 63%), and almost half report use as an educational tool. The internet offers an opportunity to provide easily-expandable, open access resources for ECG pedagogy which may be used to complement traditional methods of instruction.

  8. Wireless transmission of biosignals for hyperbaric chamber applications

    PubMed Central

    Perez-Vidal, Carlos; Gracia, Luis; Carmona, Cristian; Alorda, Bartomeu; Salinas, Antonio

    2017-01-01

    This paper presents a wireless system to send biosignals outside a hyperbaric chamber avoiding wires going through the chamber walls. Hyperbaric chambers are becoming more and more common due to new indications of hyperbaric oxygen treatments. Metallic walls physically isolate patients inside the chamber, where getting a patient’s vital signs turns into a painstaking task. The paper proposes using a ZigBee-based network to wirelessly transmit the patient's biosignals to the outside of the chamber. In particular, a wearable battery supported device has been designed, implemented and tested. Although the implementation has been conducted to transmit the electrocardiography signal, the device can be easily adapted to consider other biosignals. PMID:28296900

  9. A Case of Cardiac Cephalalgia Showing Reversible Coronary Vasospasm on Coronary Angiogram

    PubMed Central

    Yang, YoungSoon; Jin, Dong Gyu; Jang, Il Mi; Jang, YoungHee; Na, Hae Ri; Kim, SanYun

    2010-01-01

    Background Under certain conditions, exertional headaches may reflect coronary ischemia. Case Report A 44-year-old woman developed intermittent exercise-induced headaches with chest tightness over a period of 10 months. Cardiac catheterization followed by acetylcholine provocation demonstrated a right coronary artery spasm with chest tightness, headache, and ischemic effect of continuous electrocardiography changes. The patient's headache disappeared following intra-arterial nitroglycerine injection. Conclusions A coronary angiogram with provocation study revealed variant angina and cardiac cephalalgia, as per the International Classification of Headache Disorders (code 10.6). We report herein a patient with cardiac cephalalgia that manifested as reversible coronary vasospasm following an acetylcholine provocation test. PMID:20607049

  10. Arrhythmogenic Right Ventricular Cardiomyopathy with Multiple Thrombi and Ventricular Tachycardia of Atypical Left Branch Bundle Block Morphology.

    PubMed

    Gong, Shenzhen; Wei, Xin; Liu, Guyue; Wu, Feng; Chen, Xiaoping

    2018-04-06

    A 61-year-old male patient was admitted to our hospital with recurrent palpitations and syncope. Electrocardiography, echocardiography, and contrast-enhanced computed tomography were performed. The patient was diagnosed with arrhythmogenic right ventricular cardiomyopathy (ARVC) complicated by multiple thrombi, and ventricular tachycardia (VT) without typical left bundle branch block (LBBB) morphology. This case suggests that VT is not always the sole contributor to syncope and death in patients with ARVC, and pulmonary embolism should be considered. Furthermore, VT with typical LBBB morphology is not an absolute necessity as a major criterion for the diagnosis of ARVC when the right heart is extremely enlarged.

  11. Methods for Improving the Diagnosis of a Brugada ECG Pattern.

    PubMed

    Gottschalk, Byron H; Garcia-Niebla, Javier; Anselm, Daniel D; Glover, Benedict; Baranchuk, Adrian

    2016-03-01

    Brugada syndrome (BrS) is an inherited channelopathy that predisposes individuals to malignant arrhythmias and can lead to sudden cardiac death. The condition is characterized by two electrocardiography (ECG) patterns: the type-1 or "coved" ECG and the type-2 or "saddleback" ECG. Although the type-1 Brugada ECG pattern is diagnostic for the condition, the type-2 Brugada ECG pattern requires differential diagnosis from conditions that produce a similar morphology. In this article, we present a case that is suspicious but not diagnostic for BrS and discuss the application of ECG methodologies for increasing or decreasing suspicion for a diagnosis of BrS. © 2015 Wiley Periodicals, Inc.

  12. Successful Radiofrequency Catheter Ablation for Wolff-Parkinson-White Syndrome Within the Neck of a Coronary Sinus Diverticulum

    PubMed Central

    Jang, Sung-Won; Kim, Dong-Bin; Kwon, Bum-Jun; Cho, Eun-Joo; Shin, Woo-Seung; Kim, Ji-Hoon; Jin, Seung-Won; Oh, Yong-Seog; Lee, Man-Young; Kim, Jae-Hyung

    2009-01-01

    Posteroseptal accessory pathways are often associated with coronary sinus diverticula. These diverticula contain myocardial coats which serve as a bypass tract. We report a 54-year-old woman who underwent radiofrequency (RF) catheter ablation for Wolff-Parkinson-White (WPW) syndrome. The surface electrocardiography (ECG) demonstrated pre-excitation, indicating a posteroseptal accessory pathway. A catheter ablation via a transaortic approach failed to ablate the accessory pathway. Coronary sinus venography revealed the presence of a diverticulum near the ostium. An electrogram in the neck of the diverticulum showed the coronary sinus myocardial extension potential, which was successfully ablated by delivery of RF energy. PMID:19949625

  13. The effect of sham feeding on neurocardiac regulation in healthy human volunteers

    PubMed Central

    Kamath, Markad V; Spaziani, Robert; Ullal, Sangeeta; Tougas, Gervais; Guzman, Juan C; Morillo, Carlos; Capogna, Joshua; Al-Bayati, Mohammed; Armstrong, David

    2007-01-01

    BACKGROUND: Distension and electrical stimuli in the esophagus alter heart rate variability (HRV) consistent with activation of vagal afferent and efferent pathways. Sham feeding stimulates gastric acid secretion by means of vagal efferent pathways. It is not known, however, whether activation of vagal efferent pathways is organ- or stimulus-specific. OBJECTIVE: To test the hypothesis that sham feeding increases the high frequency (HF) component of HRV, indicating increased neurocardiac vagal activity in association with the known, vagally mediated, increase in gastric acid secretion. METHODS: Continuous electrocardiography recordings were obtained in 12 healthy, semirecumbent subjects during consecutive 45 min baseline, 20 min sham feeding (standard hamburger meal) and 45 min recovery periods. The R-R intervals and beat-to-beat heart rate signal were determined from digitized electrocardiography recordings; power spectra were computed from the heart rate signal to determine sympathetic (low frequency [LF]) and vagal (HF) components of HRV. RESULTS: Heart rate increased during sham feeding (median 70.8 beats/min, 95% CI 66.0 to 77.6; P<0.001), compared with baseline (63.6, 95% CI 60.8 to 70.0) and returned to baseline levels within 45 min. Sham feeding increased the LF to HF area ratio (median: 1.55, 95% C.I 1.28 to 1.77; P<0.021, compared with baseline (1.29, 95% CI 1.05 to 1.46); this increase in LF to HF area ratio was associated with a decrease in the HF component of HRV. CONCLUSIONS: Sham feeding produces a reversible increase in heart rate that is attributable to a decrease in neurocardiac parasympathetic activity despite its known ability to increase vagally mediated gastric acid secretion. These findings suggest that concurrent changes in cardiac and gastric function are modulated independently by vagal efferent fibres and that vagally mediated changes in organ function are stimulus- and organ-specific. PMID:18026575

  14. Non-contact detection of myocardium's mechanical activity by ultrawideband RF-radar and interpretation applying electrocardiography

    NASA Astrophysics Data System (ADS)

    Thiel, F.; Kreiseler, D.; Seifert, F.

    2009-11-01

    Electromagnetic waves can propagate through the body and are reflected at interfaces between materials with different dielectric properties. Therefore the reason for using ultrawideband (UWB) radar for probing the human body in the frequency range from 100 MHz up to 10 GHz is obvious and suggests an ability to monitor the motion of organs within the human body as well as obtaining images of internal structures. The specific advantages of UWB sensors are high temporal and spatial resolutions, penetration into object, low integral power, and compatibility with established narrowband systems. The sensitivity to ultralow power signals makes them suitable for human medical applications including mobile and continuous noncontact supervision of vital functions. Since no ionizing radiation is used, and due to the ultralow specific absorption rate applied, UWB techniques permit noninvasive sensing with no potential risks. This research aims at the synergetic use of UWB sounding combined with magnetic resonance imaging (MRI) to gain complementary information for improved functional diagnosis and imaging, especially to accelerate and enhance cardiac MRI by applying UWB radar as a noncontact navigator of myocardial contraction. To this end a sound understanding of how myocardial's mechanic is rendered by reflected and postprocessed UWB radar signals must be achieved. Therefore, we have executed the simultaneous acquisition and evaluation of radar signals with signals from a high-resolution electrocardiogram. The noncontact UWB illumination was done from several radiographic standard positions to monitor selected superficial myocardial areas during the cyclic physiological myocardial deformation in three different respiratory states. From our findings we could conclude that UWB radar can serve as a navigator technique for high and ultrahigh field magnetic resonance imaging and can be beneficial preserving the high resolution capability of this imaging modality. Furthermore it can potentially be used to support standard electrocardiography (ECG) analysis by complementary information where sole ECG analysis fails, e.g., electromechanical dissociation.

  15. Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm.

    PubMed

    Iyama, Yuji; Nakaura, Takeshi; Yokoyama, Koichi; Kidoh, Masafumi; Harada, Kazunori; Oda, Seitaro; Tokuyasu, Shinichi; Yamashita, Yasuyuki

    This study aimed to evaluate the feasibility of a low contrast, low-radiation dose protocol of 80-peak kilovoltage (kVp) with prospective electrocardiography-gated cardiac computed tomography (CT) using knowledge-based iterative model reconstruction (IMR). Thirty patients underwent an 80-kVp prospective electrocardiography-gated cardiac CT with low-contrast agent (222-mg iodine per kilogram of body weight) dose. We also enrolled 30 consecutive patients who were scanned with a 120-kVp cardiac CT with filtered back projection using the standard contrast agent dose (370-mg iodine per kilogram of body weight) as a historical control group. We evaluated the radiation dose for the 2 groups. The 80-kVp images were reconstructed with filtered back projection (protocol A), hybrid iterative reconstruction (HIR, protocol B), and IMR (protocol C). We compared CT numbers, image noise, and contrast-to-noise ratio among 120-kVp protocol, protocol A, protocol B, and protocol C. In addition, we compared the noise reduction rate between HIR and IMR. Two independent readers compared image contrast, image noise, image sharpness, unfamiliar image texture, and overall image quality among the 4 protocols. The estimated effective dose (ED) of the 80-kVp protocol was 74% lower than that of the 120-kVp protocol (1.4 vs 5.4 mSv). The contrast-to-noise ratio of protocol C was significantly higher than that of protocol A. The noise reduction rate of IMR was significantly higher than that of HIR (P < 0.01). There was no significant difference in almost all qualitative image quality between 120-kVp protocol and protocol C except for image contrast. A 80-kVp protocol with IMR yields higher image quality with 74% decreased radiation dose and 40% decreased contrast agent dose as compared with a 120-kVp protocol, while decreasing more image noise compared with the 80-kVp protocol with HIR.

  16. Novel Tool for Complete Digitization of Paper Electrocardiography Data.

    PubMed

    Ravichandran, Lakshminarayan; Harless, Chris; Shah, Amit J; Wick, Carson A; Mcclellan, James H; Tridandapani, Srini

    We present a Matlab-based tool to convert electrocardiography (ECG) information from paper charts into digital ECG signals. The tool can be used for long-term retrospective studies of cardiac patients to study the evolving features with prognostic value. To perform the conversion, we: 1) detect the graphical grid on ECG charts using grayscale thresholding; 2) digitize the ECG signal based on its contour using a column-wise pixel scan; and 3) use template-based optical character recognition to extract patient demographic information from the paper ECG in order to interface the data with the patients' medical record. To validate the digitization technique: 1) correlation between the digital signals and signals digitized from paper ECG are performed and 2) clinically significant ECG parameters are measured and compared from both the paper-based ECG signals and the digitized ECG. The validation demonstrates a correlation value of 0.85-0.9 between the digital ECG signal and the signal digitized from the paper ECG. There is a high correlation in the clinical parameters between the ECG information from the paper charts and digitized signal, with intra-observer and inter-observer correlations of 0.8-0.9 (p < 0.05), and kappa statistics ranging from 0.85 (inter-observer) to 1.00 (intra-observer). The important features of the ECG signal, especially the QRST complex and the associated intervals, are preserved by obtaining the contour from the paper ECG. The differences between the measures of clinically important features extracted from the original signal and the reconstructed signal are insignificant, thus highlighting the accuracy of this technique. Using this type of ECG digitization tool to carry out retrospective studies on large databases, which rely on paper ECG records, studies of emerging ECG features can be performed. In addition, this tool can be used to potentially integrate digitized ECG information with digital ECG analysis programs and with the patient's electronic medical record.

  17. Diagnostic performance of coronary computed tomography angiography versus exercise electrocardiography for coronary artery disease: a systematic review and meta-analysis

    PubMed Central

    Yin, Xinxin; Zheng, Wen; Ma, Jingjing; Hao, Panpan

    2016-01-01

    Background Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. Methods We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Results Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95–0.99] and 0.66 (95% CIs: 0.59–0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81–0.87) and 0.75 (95% CIs: 0.71–0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07–346.55) and 6.28 (95% CIs: 2.06–19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks’ test showed no potential publication bias (P=0.17). Conclusions CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD. PMID:27499958

  18. Non-contact detection of myocardium's mechanical activity by ultrawideband RF-radar and interpretation applying electrocardiography.

    PubMed

    Thiel, F; Kreiseler, D; Seifert, F

    2009-11-01

    Electromagnetic waves can propagate through the body and are reflected at interfaces between materials with different dielectric properties. Therefore the reason for using ultrawideband (UWB) radar for probing the human body in the frequency range from 100 MHz up to 10 GHz is obvious and suggests an ability to monitor the motion of organs within the human body as well as obtaining images of internal structures. The specific advantages of UWB sensors are high temporal and spatial resolutions, penetration into object, low integral power, and compatibility with established narrowband systems. The sensitivity to ultralow power signals makes them suitable for human medical applications including mobile and continuous noncontact supervision of vital functions. Since no ionizing radiation is used, and due to the ultralow specific absorption rate applied, UWB techniques permit noninvasive sensing with no potential risks. This research aims at the synergetic use of UWB sounding combined with magnetic resonance imaging (MRI) to gain complementary information for improved functional diagnosis and imaging, especially to accelerate and enhance cardiac MRI by applying UWB radar as a noncontact navigator of myocardial contraction. To this end a sound understanding of how myocardial's mechanic is rendered by reflected and postprocessed UWB radar signals must be achieved. Therefore, we have executed the simultaneous acquisition and evaluation of radar signals with signals from a high-resolution electrocardiogram. The noncontact UWB illumination was done from several radiographic standard positions to monitor selected superficial myocardial areas during the cyclic physiological myocardial deformation in three different respiratory states. From our findings we could conclude that UWB radar can serve as a navigator technique for high and ultrahigh field magnetic resonance imaging and can be beneficial preserving the high resolution capability of this imaging modality. Furthermore it can potentially be used to support standard electrocardiography (ECG) analysis by complementary information where sole ECG analysis fails, e.g., electromechanical dissociation.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, J; Place, V; Panda, A

    Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse,more » 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over 30 patients with pacemakers without complications, including 3 cardiac MR exams.« less

  20. Prognostic value of myocardial perfusion SPECT versus exercise electrocardiography in patients with ST-segment depression on resting electrocardiography.

    PubMed

    De Lorenzo, Andrea; Hachamovitch, Rory; Kang, Xingping; Gransar, Heidi; Sciammarella, Maria G; Hayes, Sean W; Friedman, John D; Cohen, Ishac; Germano, Guido; Berman, Daniel S

    2005-01-01

    The value of exercise-induced ST-segment depression for the prognostic evaluation of patients with 1 mm of ST depression or greater on the resting electrocardiogram is controversial. Patients who underwent exercise myocardial perfusion single photon emission computed tomography (MPS) and had resting ST depression of 1 mm or greater with a nondiagnostic exercise electrocardiographic response (n = 1122) were followed up for 3.4 +/- 2.3 years. Those with paced rhythm, pre-excitation, left bundle branch block, or myocardial revascularization within the first 60 days after MPS were excluded. Additional exercise-induced ST-segment depression was considered significant if > or = 2 mm MPS was scored semiquantitatively by use of a 20-segment model of the left ventricle; the percentage of myocardium involved with stress defects (% myo) was derived by normalizing to the maximal possible score of 80. Hard events were defined as nonfatal myocardial infarction or cardiac death. A Cox analysis was used to determine independent predictors of hard events among clinical, exercise, and nuclear variables. Hard event rates increased as a function of % myo for either patients with exercise-induced ST depression (1.4%/y for normal MPS vs 4.1%/y for % myo >10%, P < .03) or those without it (0.7%/y for normal MPS vs 3.0%/y for % myo >10%, P = .0001). Age, diabetes mellitus, shortness of breath as the presenting symptom, and % myo were independent predictors of hard events. Exercise-induced ST depression was predictive of hard events only when it was 3 mm or greater. The presence and extent of perfusion defects, reflected in the % myo, had incremental prognostic value over clinical variables and also over all degrees of exercise-induced ST depression. Although MPS effectively risk-stratifies patients with resting ST depression of 1 mm or greater, the prognostic value of exercise-induced ST depression is limited in these patients, with a small added risk when severe (> or = 3 mm).

  1. Smartphone transmission of electrocardiography images to reduce time of cardiac catheterization laboratory activation.

    PubMed

    Chao, Chun-Chieh; Chen, Yi-Chun; Shih, Chun-Ming; Hou, Sen-Kuang; Seethala, Raghu R; Aisiku, Imoigele P; Huang, Chuan-Chin; Hou, Peter C; Kao, Wei-Fong

    2018-06-01

    This retrospective study evaluated the use of a smartphone application to facilitate communication between the emergency physician (EP) and the interventional cardiologist in order to minimize the time to cardiac catheterization laboratory (CCL) activation and time to percutaneous coronary intervention (PCI). We retrospectively collected pertinent time-points in the management of patients diagnosed with STEMI in the emergency department and their outcome. The primary outcome was the reduction in the time from ECG interpretation to CCL activation after the implementation of a smartphone application. A total of 84 patients were enrolled. Patients' electrocardiography (ECG) were described by traditional verbal communication via telephone (group 1, n = 40) and by additional smartphone transmission of ECG images to an interventional cardiologist (group 2, n = 44). Relevant time-points were recorded for analysis. The time from ECG interpretation to CCL activation was reduced from 28.3 ± 4.1 in group 1 to 17.6 ± 2.3 min in group 2 (p = 0.03). Similarly, the time from ECG interpretation to balloon inflation time (D2B) decreased from 93.1 to 73.4 min (p = 0.025). Comparing group 2 with group 1, the door to balloon (D2B) time improved to 90.4 ± 9.8 from 119.3 ± 16.3 min (p = 0.23), the proportion of patients with a D2B time less than 90 min increased to 70.5% from 52.5% (p = 0.09), and the mortality rate decreased to 2.2% from 12.5% (p = 0.07). The additional use of a smartphone application to transmit ECG information to interventional cardiologists by EPs facilitated communication and reduced the decision time to CCL activation and percutaneous intervention. Copyright © 2017. Published by Elsevier Taiwan LLC.

  2. Management and outcome of topical beta-blockerinduced atrioventricular block

    PubMed Central

    Özcan, Kazım Serhan; Güngör, Barış; Tekkeşin, Ahmet İlker; Altay, Servet; Ekmekçi, Ahmet; Toprak, Ercan; Yıldırım, Ersin; Çalık, Nazmi; Alper, Ahmet Taha; Gürkan, Kadir; Erdinler, İzzet; Osmonov, Damirbek

    2015-01-01

    Summary Background Topical beta-blockers have a well-established role in the treatment of glaucoma. We aimed to investigate the outcome of patients who developed symptomatic atrioventricular (AV) block induced by topical beta-blockers. Methods All patients admitted or discharged from our institution, the Siyami Ersek Training and Research Hospital, between January 2009 and January 2013 with a diagnosis of AV block were included in the study. Subjects using ophthalmic beta-blockers were recruited and followed for permanent pacemaker requirement during hospitalisation and for three months after discontinuation of the drug. A permanent pacemaker was implanted in patients in whom AV block persisted beyond 72 hours or recurred during the follow-up period. Results A total of 1 122 patients were hospitalised with a diagnosis of AV block and a permanent pacemaker was implanted in 946 cases (84.3%) during the study period. Thirteen patients using ophthalmic beta-blockers for the treatment of glaucoma and no other rate-limiting drugs were included in the study. On electrocardiography, eight patients had complete AV block and five had high-degree AV block. The ophthalmic beta-blockers used were timolol in seven patients (55%), betaxolol in four (30%), and cartelol in two cases (15%). The mean duration of ophthalmic beta-blocker treatment was 30.1 ± 15.9 months. After drug discontinuation, in 10 patients the block persisted and a permanent pacemaker was implanted. During follow up, one more patient required pacemaker implantation. Therefore in total, pacemakers were implanted in 11 out of 13 patients (84.6%). The pacemaker implantation rate did not differ according to the type of topical beta-blocker used (p = 0.37). The presence of infra-nodal block on electrocardiography was associated with higher rates of pacemaker implantation. Conclusion Our results indicate that topical beta-blockers for the treatment of glaucoma may cause severe conduction abnormalities and when AV block occurs, pacemaker implantation is required in a high percentage of the patients. PMID:26659434

  3. Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival

    NASA Technical Reports Server (NTRS)

    Armoundas, A. A.; Rosenbaum, D. S.; Ruskin, J. N.; Garan, H.; Cohen, R. J.

    1998-01-01

    OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.

  4. Heart monitoring using left ventricle impedance and ventricular electrocardiography in left ventricular assist device patients.

    PubMed

    Her, Keun; Ahn, Chi Bum; Park, Sung Min; Choi, Seong Wook

    2015-03-21

    Patients who develop critical arrhythmia during left ventricular assist device (LVAD) perfusion have a low survival rate. For diagnosis of unexpected heart abnormalities, new heart-monitoring methods are required for patients supported by LVAD perfusion. Ventricular electrocardiography using electrodes implanted in the ventricle to detect heart contractions is unsuitable if the heart is abnormal. Left ventricular impedance (LVI) is useful for monitoring heart movement but does not show abnormal action potential in the heart muscle. To detect detailed abnormal heart conditions, we obtained ventricular electrocardiograms (v-ECGs) and LVI simultaneously in porcine models connected to LVADs. In the porcine models, electrodes were set on the heart apex and ascending aorta for real-time measurements of v-ECGs and LVI. As the carrier current frequency of the LVI was adjusted to 30 kHz, it was easily derived from the original v-ECG signal by using a high-pass filter (cutoff: 10 kHz). In addition, v-ECGs with a frequency band of 0.1 - 120 Hz were easily derived using a low-pass filter. Simultaneous v-ECG and LVI data were compared to detect heart volume changes during the Q-T period when the heart contracted. A new real-time algorithm for comparison of v-ECGs and LVI determined whether the porcine heartbeats were normal or abnormal. Several abnormal heartbeats were detected using the LVADs operating in asynchronous mode, most of which were premature ventricle contractions (PVCs). To evaluate the accuracy of the new method, the results obtained were compared to normal ECG data and cardiac output measured simultaneously using commercial devices. The new method provided more accurate detection of abnormal heart movements. This method can be used for various heart diseases, even those in which the cardiac output is heavily affected by LVAD operation.

  5. Development of a Multi-Channel, High Frequency QRS Electrocardiograph

    NASA Technical Reports Server (NTRS)

    DePalma, Jude L.

    2003-01-01

    With the advent of the ISS era and the potential requirement for increased cardiovascular monitoring of crewmembers during extended EVAs, NASA flight surgeons would stand to benefit from an evolving technology that allows for a more rapid diagnosis of myocardial ischemia compared to standard electrocardiography. Similarly, during the astronaut selection process, NASA flight surgeons and other physicians would also stand to benefit from a completely noninvasive technology that, either at rest or during maximal exercise tests, is more sensitive than standard ECG in identifying the presence of ischemia. Perhaps most importantly, practicing cardiologists and emergency medicine physicians could greatly benefit from such a device as it could augment (or even replace) standard electrocardiography in settings where the rapid diagnosis of myocardial ischemia (or the lack thereof) is required for proper clinical decision-making. A multi-channel, high-frequency QRS electrocardiograph is currently under development in the Life Sciences Research Laboratories at JSC. Specifically the project consisted of writing software code, some of which contained specially-designed digital filters, which will be incorporated into an existing commercial software program that is already designed to collect, plot and analyze conventional 12-lead ECG signals on a desktop, portable or palm PC. The software will derive the high-frequency QRS signals, which will be analyzed (in numerous ways) and plotted alongside of the conventional ECG signals, giving the PC-viewing clinician advanced diagnostic information that has never been available previously in all 12 ECG leads simultaneously. After the hardware and software for the advanced digital ECG monitor have been fully integrated, plans are to use the monitor to begin clinical studies both on healthy subjects and on patients with known coronary artery disease in both the outpatient and hospital settings. The ultimate goal is to get the technology out into the clinical world, where it has the potential to save lives.

  6. Comparison of exercise electrocardiography and stress perfusion CMR for the detection of coronary artery disease in women

    PubMed Central

    2012-01-01

    Background Exercise electrocardiography (ECG) is frequently used in the work-up of patients with suspected coronary artery disease (CAD), however the accuracy is reduced in women. Cardiovascular magnetic resonance (CMR) stress testing can accurately diagnose CAD in women. To date, a direct comparison of CMR to ECG has not been performed. Methods and results We prospectively enrolled 88 consecutive women with chest pain or other symptoms suggestive of CAD. Patients underwent a comprehensive clinical evaluation, exercise ECG, a CMR stress test including perfusion and infarct imaging, and x-ray coronary angiography (CA) within 24 hours. CAD was defined as stenosis ≥70% on quantitative analysis of CA. Exercise ECG, CMR and CA was completed in 68 females (age 66.4 ± 8.8 years, number of CAD risk factors 3.5 ± 1.4). The prevalence of CAD on CA was 29%. The Duke treadmill score (DTS) in the entire group was −3.0 ± 5.4 and was similar in those with and without CAD (−4.5 ± 5.8 and −2.4 ± 5.1; P = 0.12). Sensitivity, specificity and accuracy for CAD diagnosis was higher for CMR compared with exercise ECG (sensitivities 85% and 50%, P = 0.02, specificities 94% and 73%, P = 0.01, and accuracies 91% and 66%, P = 0.0007, respectively). Even after applying the DTS the accuracy of CMR was higher compared to exercise ECG (area under ROC curve 0.94 ± 0.03 vs 0.56 ± 0.07; P = 0.0001). Conclusions In women with intermediate-to-high risk for CAD who are able to exercise and have interpretable resting ECG, CMR stress perfusion imaging has higher accuracy for the detection of relevant obstruction of the epicardial coronaries when directly compared to exercise ECG. PMID:22697372

  7. CSE database: extended annotations and new recommendations for ECG software testing.

    PubMed

    Smíšek, Radovan; Maršánová, Lucie; Němcová, Andrea; Vítek, Martin; Kozumplík, Jiří; Nováková, Marie

    2017-08-01

    Nowadays, cardiovascular diseases represent the most common cause of death in western countries. Among various examination techniques, electrocardiography (ECG) is still a highly valuable tool used for the diagnosis of many cardiovascular disorders. In order to diagnose a person based on ECG, cardiologists can use automatic diagnostic algorithms. Research in this area is still necessary. In order to compare various algorithms correctly, it is necessary to test them on standard annotated databases, such as the Common Standards for Quantitative Electrocardiography (CSE) database. According to Scopus, the CSE database is the second most cited standard database. There were two main objectives in this work. First, new diagnoses were added to the CSE database, which extended its original annotations. Second, new recommendations for diagnostic software quality estimation were established. The ECG recordings were diagnosed by five new cardiologists independently, and in total, 59 different diagnoses were found. Such a large number of diagnoses is unique, even in terms of standard databases. Based on the cardiologists' diagnoses, a four-round consensus (4R consensus) was established. Such a 4R consensus means a correct final diagnosis, which should ideally be the output of any tested classification software. The accuracy of the cardiologists' diagnoses compared with the 4R consensus was the basis for the establishment of accuracy recommendations. The accuracy was determined in terms of sensitivity = 79.20-86.81%, positive predictive value = 79.10-87.11%, and the Jaccard coefficient = 72.21-81.14%, respectively. Within these ranges, the accuracy of the software is comparable with the accuracy of cardiologists. The accuracy quantification of the correct classification is unique. Diagnostic software developers can objectively evaluate the success of their algorithm and promote its further development. The annotations and recommendations proposed in this work will allow for faster development and testing of classification software. As a result, this might facilitate cardiologists' work and lead to faster diagnoses and earlier treatment.

  8. In Vitro Quantification of Gutter Formation and Chimney Graft Compression in Chimney EVAR Stent-Graft Configurations Using Electrocardiography-Gated Computed Tomography.

    PubMed

    Overeem, Simon P; Donselaar, Esmé J; Boersen, Jorrit T; Groot Jebbink, Erik; Slump, Cornelis H; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2018-03-01

    To assess the dynamic behavior of chimney grafts during the cardiac cycle. Three chimney endovascular aneurysm repair (EVAR) stent-graft configurations (Endurant and Advanta V12, Endurant and Viabahn, and Endurant and BeGraft) were placed in silicone aneurysm models and subjected to physiologic flow. Electrocardiography (ECG)-gated contrast-enhanced computed tomography was used to visualize geometric changes during the cardiac cycle. Endograft and chimney graft surface, gutter volume, chimney graft angulation over the center lumen line, and the D-ratio (the ratio between the lengths of the major and minor axes) were independently assessed by 2 observers at 10 time points in the cardiac cycle. Both gutter volumes and chimney graft geometry changed significantly during the cardiac cycle in all 3 configurations (p<0.001). Gutters and endoleaks were observed in all configurations. The largest gutter volume (232.8 mm 3 ) and change in volume (20.7 mm 3 ) between systole and diastole were observed in the Endurant-Advanta configuration. These values were 2.7- and 3.0-fold higher, respectively, compared to the Endurant-Viabahn configuration and 1.7- and 1.6-fold higher as observed in the Endurant-BeGraft configuration. The Endurant-Viabahn configuration had the highest D-ratio (right, 1.26-1.35; left, 1.33-1.48), while the Endurant-BeGraft configuration had the lowest (right, 1.11-1.17; left, 1.08-1.15). Assessment of the interobserver variability showed a high correlation (intraclass correlation >0.935) between measurements. Gutter volumes and stent compression are dynamic phenomena that reshape during the cardiac cycle. Compelling differences were observed during the cardiac cycle in all configurations, with the self-expanding (Endurant-Viabahn) chimney EVAR configurations having smaller gutters and less variation in gutter volume during the cardiac cycle yet more stent compression without affecting the chimney graft surface.

  9. NOTE: Solving the ECG forward problem by means of a meshless finite element method

    NASA Astrophysics Data System (ADS)

    Li, Z. S.; Zhu, S. A.; He, Bin

    2007-07-01

    The conventional numerical computational techniques such as the finite element method (FEM) and the boundary element method (BEM) require laborious and time-consuming model meshing. The new meshless FEM only uses the boundary description and the node distribution and no meshing of the model is required. This paper presents the fundamentals and implementation of meshless FEM and the meshless FEM method is adapted to solve the electrocardiography (ECG) forward problem. The method is evaluated on a single-layer torso model, in which the analytical solution exists, and tested in a realistic geometry homogeneous torso model, with satisfactory results being obtained. The present results suggest that the meshless FEM may provide an alternative for ECG forward solutions.

  10. Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit.

    PubMed

    Singh, Jasbir K S B; Kamlin, C Omar F; Morley, Colin J; O'Donnell, Colm P F; Donath, Susan M; Davis, Peter G

    2008-05-01

    To determine the accuracy of pulse oximetry measurement of heart rate in the neonatal intensive care unit. Stable preterm infants were monitored with a pulse oximeter and an ECG. The displays of both monitors were captured on video. Heart rate data from both monitors, including measures of signal quality, were extracted and analysed using Bland Altman plots. In 30 infants the mean (SD) difference between heart rate measured by pulse oximetry and electrocardiography was -0.4 (12) beats per minute. Accuracy was maintained when the signal quality or perfusion was low. Pulse oximetry may provide a useful measurement of heart rate in the neonatal intensive care unit. Studies of this technique in the delivery room are indicated.

  11. Evolution and Evaluation of ECG Interpretation Systems-An Illustration of the Validation of Decision Support Systems

    PubMed Central

    van Bemmel, Jan H.; Kors, Jan A.; Willems, Jos L.; van Herpen, Gerard

    1990-01-01

    The last decade has shown a growing interest in medical decision making, strongly stimulated by the advent of artificial intelligence. This wave of interest is not the first one; it was preceded by other models and approaches to medical decision support. However, not all developments have resulted in equally successful decision support systems. Positive exceptions are the interpretation systems for ECGs that evolved all the way from very primitive attempts to well-accepted and highly-computerized clinical systems for which a major evaluation study (CSE, Common Standards for Quantitative Electrocardiography) is finalized in 1990. The evolution and the evaluation of the systems that took part in this study, is the subject of this paper.

  12. A case of advanced second-degree atrioventricular block in a ferret secondary to lymphoma

    PubMed Central

    Menicagli, F.; Lanza, A.; Sbrocca, F.; Baldi, A.; Spugnini, E.P.

    2016-01-01

    A female ferret was referred as an emergency for severe respiratory distress symptoms. At presentation, the patient was listlessness, dyspnoeic, and hyper-responsive. The clinical examination evidenced dyspnea with cyanosis, altered cardiac rhythm, and hepatomegaly. Electrocardiography showed an advanced second-degree atrioventricular (AV) block. The liver aspirate was diagnostic for lymphoma. The patient did not respond to supportive therapy and rapidly died. Post-mortem exams confirmed the presence of lymphoma with hepatic involvement. Moreover, a pericardial lymphocytic infiltration and a widespread myocardial nodular localization of lymphoma were evidenced as well. This condition was probably the cause of the cardiac arrhythmia. To the best of our knowledge, ours is the first report of cardiac lymphoma causing heart block in ferrets. PMID:27200273

  13. Chronic hypertension with subsequent congestive heart failure in a western lowland gorilla (Gorilla gorilla gorilla).

    PubMed

    Miller, C L; Schwartz, A M; Barnhart, J S; Bell, M D

    1999-06-01

    Chronic severe subclinical systemic hypertension was diagnosed in a 28-yr-old male western lowland gorilla (Gorilla gorilla gorilla). Thoracic radiography, electrocardiography, and echocardiography revealed an enlarged heart with a hypertrophied left ventricle, mitral regurgitation, and a persistent left bundle branch block. Enalapril, later combined with nifedipine, was of some value in reducing the hypertension, with partial reversal of cardiac enlargement and resolution of the bundle branch block. Two years after initiation of treatment, the gorilla developed lethargy and dyspnea. The diagnosis of heart failure was confirmed under anesthesia; the gorilla did not recover and was euthanized. Postmortem examination confirmed congestive heart failure with chronic, fibrosing cardiomyopathy similar to that in other gorillas.

  14. Technological Innovations from NASA

    NASA Technical Reports Server (NTRS)

    Pellis, Neal R.

    2006-01-01

    The challenge of human space exploration places demands on technology that push concepts and development to the leading edge. In biotechnology and biomedical equipment development, NASA science has been the seed for numerous innovations, many of which are in the commercial arena. The biotechnology effort has led to rational drug design, analytical equipment, and cell culture and tissue engineering strategies. Biomedical research and development has resulted in medical devices that enable diagnosis and treatment advances. NASA Biomedical developments are exemplified in the new laser light scattering analysis for cataracts, the axial flow left ventricular-assist device, non contact electrocardiography, and the guidance system for LASIK surgery. Many more developments are in progress. NASA will continue to advance technologies, incorporating new approaches from basic and applied research, nanotechnology, computational modeling, and database analyses.

  15. Surgical management of subvalvular aortic stenosis and mitral dysplasia in a golden retriever.

    PubMed

    White, R N; Boswood, A; Garden, O A; Hammond, R A

    1997-06-01

    A 12-month-old neutered male golden retriever was presented with a history of lethargy and exercise intolerance. Clinical examination, electrocardiography, radiography and echocardiography supported a diagnosis of fixed subvalvular aortic stenosis with a Doppler pressure gradient of 77.5 mmHg. Surgical inspection also revealed gross structural abnormalities of the mitral valve consistent with mitral dysplasia. Intervention consisted of resection of the dysplastic mitral valve and the subvalvular aortic stenosis. The mitral valve was replaced with a bioprosthetic valve. Total cardiopulmonary bypass time was 65 minutes and aortic cross-clamp time was 55 minutes. A full recovery was made and 11 months postoperatively the aortic transvalvular gradient was 30 mmHg. At the time of writing, 12 months after surgery, the dog was clinically normal and requires no medication.

  16. A stretchable electrode array for non-invasive, skin-mounted measurement of electrocardiography (ECG), electromyography (EMG) and electroencephalography (EEG).

    PubMed

    Ma, Rui; Kim, Dae-Hyeong; McCormick, Martin; Coleman, Todd; Rogers, John

    2010-01-01

    This paper reports a class of stretchable electrode array capable of intimate, conformal integration onto the curvilinear surfaces of skin on the human body. The designs employ conventional metallic conductors but in optimized mechanical layouts, on soft, thin elastomeric substrates. These devices exhibit an ability to record spontaneous EEG activity even without conductive electrolyte gels, with recorded alpha rhythm responses that are 40% stronger than those collected using conventional tin electrodes and gels under otherwise similar conditions. The same type of device can also measure high quality ECG and EMG signals. The results suggest broad utility for skin-mounted measurements of electrical activity in the body, with advantages in signal levels, wearability and modes of integration compared to alternatives.

  17. Importance of the concept of inner organs-dental relations in dentistry.

    PubMed

    Abasova, I; Rustamova, P; Seidbekov, O

    2009-12-01

    The current article is presenting an effective treatment scheme, providing reliable positive result of therapy and prophylaxis of dental diseases and its complications on the patients through the study of pathology of meridian - inner organs - dental system, bound by system of traces - meridians, using Doppler ultrasonography, rheovasography, photoplethysmography, Electroacupuncture, ultrasound investigations of the inner organs, X-Ray, laboratory investigations, electrocardiography methods. We had studied the efficiency of the odontic Microsystem, developed by R. Voll and R. Dale in dental practice by oral examination of 100 patients, average aged 25,5+/-0,74, which were divided into three groups. The necessity of complex treatment of the patients with pathology of inner organs and related with that demineralization process of the hard tissues of the teeth and the periodontitis had been demonstrated.

  18. The electrocardiographic Holter monitoring in experimental veterinary practice.

    PubMed

    Scheer, P; Svoboda, P; Sepsi, M; Janecková, K; Doubek, J

    2010-01-01

    The long-term electrocardiographic recording with retrospective evaluation (Holter system) has been widely used not only in cardiology, but also in other disciplines of internal medicine and in pharmaceutical research. The Holter system can be used in mini-pig, sheep, dog, cat, rabbit, ferret, and rat. In this paper hardware, software, and anesthesia requirements are summarized with respect to the experimental work with various species. As the Holter systems work in bipolar mode, the use of bipolar leads in sagittal and transversal planes has been proved to be the most appropriate because of large amplitude of QRS complex and uncomplicated consequent automatic analysis of the record. In conclusion, Holter electrocardiography represents a simple and applicable method for monitoring the electrical activity of the heart in small animals' experimental studies.

  19. Asphyxia-activated corticocardiac signaling accelerates onset of cardiac arrest.

    PubMed

    Li, Duan; Mabrouk, Omar S; Liu, Tiecheng; Tian, Fangyun; Xu, Gang; Rengifo, Santiago; Choi, Sarah J; Mathur, Abhay; Crooks, Charles P; Kennedy, Robert T; Wang, Michael M; Ghanbari, Hamid; Borjigin, Jimo

    2015-04-21

    The mechanism by which the healthy heart and brain die rapidly in the absence of oxygen is not well understood. We performed continuous electrocardiography and electroencephalography in rats undergoing experimental asphyxia and analyzed cortical release of core neurotransmitters, changes in brain and heart electrical activity, and brain-heart connectivity. Asphyxia stimulates a robust and sustained increase of functional and effective cortical connectivity, an immediate increase in cortical release of a large set of neurotransmitters, and a delayed activation of corticocardiac functional and effective connectivity that persists until the onset of ventricular fibrillation. Blocking the brain's autonomic outflow significantly delayed terminal ventricular fibrillation and lengthened the duration of detectable cortical activities despite the continued absence of oxygen. These results demonstrate that asphyxia activates a brainstorm, which accelerates premature death of the heart and the brain.

  20. Cardiological database management system as a mediator to clinical decision support.

    PubMed

    Pappas, C; Mavromatis, A; Maglaveras, N; Tsikotis, A; Pangalos, G; Ambrosiadou, V

    1996-03-01

    An object-oriented medical database management system is presented for a typical cardiologic center, facilitating epidemiological trials. Object-oriented analysis and design were used for the system design, offering advantages for the integrity and extendibility of medical information systems. The system was developed using object-oriented design and programming methodology, the C++ language and the Borland Paradox Relational Data Base Management System on an MS-Windows NT environment. Particular attention was paid to system compatibility, portability, the ease of use, and the suitable design of the patient record so as to support the decisions of medical personnel in cardiovascular centers. The system was designed to accept complex, heterogeneous, distributed data in various formats and from different kinds of examinations such as Holter, Doppler and electrocardiography.

  1. Predictive use of routine 24-hour electrocardiography in suspected Adams-Stokes syndrome. Comparison with cardiac rhythm during symptoms.

    PubMed Central

    Abdon, N J; Johansson, B W; Lessem, J

    1982-01-01

    Using strictly defined criteria of significant arrhythmias, long term electrocardiographic recording has been evaluated for confirmation of arrhythmias as the cause of cerebral symptoms in 81 patients with suspected Adams-Stokes syndrome. Extension of long term electrocardiographic recording for more than 24 hours gives marginal additional information at a high cost. Among 43 patients monitored until symptoms appeared, non cardiogenic causes were confirmed in 20 of 22 patients because the recording showed normal rhythm during symptoms. Fifteen of 21 patients with a significant arrhythmia during an asymptomatic 24 hour recording later had the same arrhythmia during symptoms. Of 38 patients who failed to develop symptoms, 21 had a significant arrhythmia detectable within 24 hours and 23 when 48 hours of recording were analysed. PMID:7082502

  2. High efficiency processing for reduced amplitude zones detection in the HRECG signal

    NASA Astrophysics Data System (ADS)

    Dugarte, N.; Álvarez, A.; Balacco, J.; Mercado, G.; Gonzalez, A.; Dugarte, E.; Olivares, A.

    2016-04-01

    Summary - This article presents part of a more detailed research proposed in the medium to long term, with the intention of establishing a new philosophy of electrocardiogram surface analysis. This research aims to find indicators of cardiovascular disease in its early stage that may go unnoticed with conventional electrocardiography. This paper reports the development of a software processing which collect some existing techniques and incorporates novel methods for detection of reduced amplitude zones (RAZ) in high resolution electrocardiographic signal (HRECG).The algorithm consists of three stages, an efficient processing for QRS detection, averaging filter using correlation techniques and a step for RAZ detecting. Preliminary results show the efficiency of system and point to incorporation of techniques new using signal analysis with involving 12 leads.

  3. Electroconvulsive therapy-induced Wolff-Parkinson-White syndrome: a case report.

    PubMed

    Enomoto, Shingo; Yoshino, Aihide; Takase, Bonpei; Kuwahara, Tatsuro; Tatsuzawa, Yasutaka; Nomura, Soichiro

    2013-01-01

    Wolff-Parkinson-White (WPW) syndrome is characterized by premature ventricular excitation due to the presence of an abnormal accessory pathway. Electrocardiography (ECG) of patients with WPW syndrome portrays a short PR interval and a wide QRS interval with a delta wave. Herein, we report the case of a patient with schizophrenia who developed a wide QRS interval with a delta wave immediately following electroconvulsive therapy (ECT). Initially, the delta wave disappeared within 2 days after ECT. However, the duration of the delta wave increased exponentially to 4 months when ECT was repeated. Although the patient's cardiocirculatory dynamics remained normal, we continued to monitor her ECG until the delta wave disappeared because WPW syndrome can lead to serious arrhythmia. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Wavelet-promoted sparsity for non-invasive reconstruction of electrical activity of the heart.

    PubMed

    Cluitmans, Matthijs; Karel, Joël; Bonizzi, Pietro; Volders, Paul; Westra, Ronald; Peeters, Ralf

    2018-05-12

    We investigated a novel sparsity-based regularization method in the wavelet domain of the inverse problem of electrocardiography that aims at preserving the spatiotemporal characteristics of heart-surface potentials. In three normal, anesthetized dogs, electrodes were implanted around the epicardium and body-surface electrodes were attached to the torso. Potential recordings were obtained simultaneously on the body surface and on the epicardium. A CT scan was used to digitize a homogeneous geometry which consisted of the body-surface electrodes and the epicardial surface. A novel multitask elastic-net-based method was introduced to regularize the ill-posed inverse problem. The method simultaneously pursues a sparse wavelet representation in time-frequency and exploits correlations in space. Performance was assessed in terms of quality of reconstructed epicardial potentials, estimated activation and recovery time, and estimated locations of pacing, and compared with performance of Tikhonov zeroth-order regularization. Results in the wavelet domain obtained higher sparsity than those in the time domain. Epicardial potentials were non-invasively reconstructed with higher accuracy than with Tikhonov zeroth-order regularization (p < 0.05), and recovery times were improved (p < 0.05). No significant improvement was found in terms of activation times and localization of origin of pacing. Next to improved estimation of recovery isochrones, which is important when assessing substrate for cardiac arrhythmias, this novel technique opens potentially powerful opportunities for clinical application, by allowing to choose wavelet bases that are optimized for specific clinical questions. Graphical Abstract The inverse problem of electrocardiography is to reconstruct heart-surface potentials from recorded bodysurface electrocardiograms (ECGs) and a torso-heart geometry. However, it is ill-posed and solving it requires additional constraints for regularization. We introduce a regularization method that simultaneously pursues a sparse wavelet representation in time-frequency and exploits correlations in space. Our approach reconstructs epicardial (heart-surface) potentials with higher accuracy than common methods. It also improves the reconstruction of recovery isochrones, which is important when assessing substrate for cardiac arrhythmias. This novel technique opens potentially powerful opportunities for clinical application, by allowing to choose wavelet bases that are optimized for specific clinical questions.

  5. Willem Einthoven and the birth of clinical electrocardiography a hundred years ago.

    PubMed

    Barold, S Serge

    2003-01-01

    The first electrocardiogram (ECG) from the intact human heart was recorded with a mercury capillary electrometer by Augustus Waller in May 1887 at St. Mary's Hospital, London. The tracings were poor and exhibited only 2 distorted deflections. Willem Einthoven (1860-1927) who was professor of physiology at the University of Leiden, The Netherlands, began his studies of the ECG with the mercury capillary electrometer, and improved its distortion mathematically so that he was finally able to register a good representation of the ECG before the beginning of the twentieth century. He later further improved ECG recordings with the introduction of a string galvanometer of his design. Einthoven published his first article about the string galvanometer in 1901, followed by a more detailed description in 1903 which included a report of ECGs taken with the new instrument. The year 2002 marks the centennial of Willem Einthoven's first recording of the ECG in a clinically applicable fashion with the string galvanometer. The clinical use of Einthoven's immobile equipment required transtelephonic transmission of the ECG from the physiology laboratory to the clinic at the Academic Hospital about a mile away as documented in the 1906 paper on the "télécardiogramme". This report contained a wealth of ECG patterns and arrhythmias. Einthoven developed a system of electrocardiographic standardization that continues to be used all over the world and introduced the triaxial bipolar system with 3 limb leads and thus established uniformity of the recording process. Einthoven also conceived the famous equilateral triangle with leads I, II, and III at its sides and the calculation of the electrical axis (in the frontal plane) depicted as a single vector with an arrow at the center of the triangle. Einthoven recognized the great potential importance of the ECG as a diagnostic and investigative tool and his achievements made him the founder of modern electrocardiography. He was awarded the Nobel Prize in 1924 (2 years after Waller's death) in physiology and medicine, "for the discovery of the mechanism of the electrocardiogram."

  6. Single Doses up to 800 mg of E-52862 Do Not Prolong the QTc Interval – A Retrospective Validation by Pharmacokinetic-Pharmacodynamic Modelling of Electrocardiography Data Utilising the Effects of a Meal on QTc to Demonstrate ECG Assay Sensitivity

    PubMed Central

    Täubel, Jörg; Ferber, Georg; Lorch, Ulrike; Wang, Duolao; Sust, Mariano; Camm, A. John

    2015-01-01

    Background E-52862 is a Sigma-1 receptor antagonist (S1RA) currently under investigation as a potential analgesic medicine. We successfully applied a concentration-effect model retrospectively to a four-way crossover Phase I single ascending dose study and utilized the QTc shortening effects of a meal to demonstrate assay sensitivity by establishing the time course effects from baseline in all four periods, independently from any potential drug effects. Methods Thirty two healthy male and female subjects were included in four treatment periods to receive single ascending doses of 500 mg, 600 mg or 800 mg of E-52862 or placebo. PK was linear over the dose range investigated and doses up to 600 mg were well tolerated. The baseline electrocardiography (ECG) measurements on Day-1 were time-matched with ECG and pharmacokinetic (PK) samples on Day 1 (dosing day). Results In this conventional mean change to time-matched placebo analysis, the largest time-matched difference to placebo QTcI was 1.44 ms (90% CI: -4.04, 6.93 ms) for 500 mg; -0.39 ms (90% CI: -3.91, 3.13 ms) for 600 mg and 1.32 ms (90% CI: -1.89, 4.53 ms) for 800 mg of E-52862, thereby showing the absence of any QTc prolonging effect at the doses tested. In addition concentration-effect models, one based on the placebo corrected change from baseline and one for the change of QTcI from average baseline with time as fixed effect were fitted to the data confirming the results of the time course analysis. Conclusion The sensitivity of this study to detect small changes in the QTc interval was confirmed by demonstrating a shortening of QTcF of -8.1 (90% CI: -10.4, -5.9) one hour and -7.2 (90% CI: -9.4, -5.0) three hours after a standardised meal. Trial Registration EU Clinical Trials Register EudraCT 2010 020343 13 PMID:26291080

  7. Safety and efficacy of extracorporeal shock wave myocardial revascularization therapy for refractory angina pectoris.

    PubMed

    Cassar, Andrew; Prasad, Megha; Rodriguez-Porcel, Martin; Reeder, Guy S; Karia, Darshak; DeMaria, Anthony N; Lerman, Amir

    2014-03-01

    To assess the safety and efficacy of extracorporeal shockwave myocardial revascularization (ESMR) therapy in treating patients with refractory angina pectoris. A single-arm multicenter prospective trial to assess safety and efficacy of the ESMR therapy in patients with refractory angina (class III/IV angina) was performed. Screening exercise treadmill tests and pharmacological single-photon emission computed tomography (SPECT) were performed for all patients to assess exercise capacity and ischemic burden. Patients were treated with 9 sessions of ESMR to ischemic areas over 9 weeks. Efficacy end points were exercise capacity by using treadmill test as well as ischemic burden on pharmacological SPECT at 4 months after the last ESMR treatment. Safety measures included electrocardiography, echocardiography, troponin, creatine kinase, and brain natriuretic peptide testing, and pain questionnaires. Fifteen patients with medically refractory angina and no revascularization options were enrolled. There was a statistically significant mean increase of 122.3±156.9 seconds (38% increase compared with baseline; P=.01) in exercise treadmill time from baseline (319.8±157.2 seconds) to last follow-up after the ESMR treatment (422.1±183.3 seconds). There was no improvement in the summed stress perfusion scores after pharmacologically induced stress SPECT at 4 months after the last ESMR treatment in comparison to that at screening; however, SPECT summed stress score revealed that untreated areas had greater progression in ischemic burden vs treated areas (3.69±6.2 vs 0.31±4.5; P=.03). There was no significant change in the mean summed echo score from baseline to posttreatment (0.4±5.1; P=.70). The ESMR therapy was performed safely without any adverse events in electrocardiography, echocardiography, troponins, creatine kinase, or brain natriuretic peptide. Pain during the ESMR treatment was minimal (a score of 0.5±1.2 to 1.1±1.2 out of 10). In this multicenter feasibility study, ESMR seems to be a safe and efficacious treatment for patients with refractory angina pectoris. However, larger sham-controlled trials will be required to confirm these findings. Copyright © 2014 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  8. Screening for Cardiovascular Disease Risk With Electrocardiography: US Preventive Services Task Force Recommendation Statement.

    PubMed

    Curry, Susan J; Krist, Alex H; Owens, Douglas K; Barry, Michael J; Caughey, Aaron B; Davidson, Karina W; Doubeni, Chyke A; Epling, John W; Kemper, Alex R; Kubik, Martha; Landefeld, C Seth; Mangione, Carol M; Silverstein, Michael; Simon, Melissa A; Tseng, Chien-Wen; Wong, John B

    2018-06-12

    Cardiovascular disease (CVD), which encompasses atherosclerotic conditions such as coronary heart disease, cerebrovascular disease, and peripheral arterial disease, is the most common cause of death among adults in the United States. Treatment to prevent CVD events by modifying risk factors is currently informed by CVD risk assessment with tools such as the Framingham Risk Score or the Pooled Cohort Equations, which stratify individual risk to inform treatment decisions. To update the 2012 US Preventive Services Task Force (USPSTF) recommendation on screening for coronary heart disease with electrocardiography (ECG). The USPSTF reviewed the evidence on whether screening with resting or exercise ECG improves health outcomes compared with the use of traditional CVD risk assessment alone in asymptomatic adults. For asymptomatic adults at low risk of CVD events (individuals with a 10-year CVD event risk less than 10%), it is very unlikely that the information from resting or exercise ECG (beyond that obtained with conventional CVD risk factors) will result in a change in the patient's risk category as assessed by the Framingham Risk Score or Pooled Cohort Equations that would lead to a change in treatment and ultimately improve health outcomes. Possible harms are associated with screening with resting or exercise ECG, specifically the potential adverse effects of subsequent invasive testing. For asymptomatic adults at intermediate or high risk of CVD events, there is insufficient evidence to determine the extent to which information from resting or exercise ECG adds to current CVD risk assessment models and whether information from the ECG results in a change in risk management and ultimately reduces CVD events. As with low-risk adults, possible harms are associated with screening with resting or exercise ECG in asymptomatic adults at intermediate or high risk of CVD events. The USPSTF recommends against screening with resting or exercise ECG to prevent CVD events in asymptomatic adults at low risk of CVD events. (D recommendation) The USPSTF concludes that the current evidence is insufficient to assess the balance of benefits and harms of screening with resting or exercise ECG to prevent CVD events in asymptomatic adults at intermediate or high risk of CVD events. (I statement).

  9. Non‐clinical safety evaluation of repeated intramuscular administration of the AS15 immunostimulant combined with various antigens in rabbits and cynomolgus monkeys

    PubMed Central

    Garçon, N.; Silvano, J.; Kuper, C. F.; Baudson, N.; Gérard, C.; Forster, R.

    2015-01-01

    Abstract Combination of tumor antigens with immunostimulants is a promising approach in cancer immunotherapy. We assessed animal model toxicity of AS15 combined with various tumor antigens: WT1 (rabbits), or p501, dHER2 and recPRAME (cynomolgus monkeys), administered in seven or 20 dose regimens versus a saline control. Clinical and ophthalmological examinations, followed by extensive post‐mortem pathological examinations, were performed on all animals. Blood hematology and biochemistry parameters were also assessed. Antigen‐specific antibody titers were determined by enzyme‐linked immunosorbent assay. Additional assessments in monkeys included electrocardiography and immunohistochemical evaluations of the p501 expression pattern. Transient increases in body temperature were observed 4 h or 24 h after injections of recPRAME + AS15 and dHER2 + AS15. Edema and erythema were observed up to 1 week after most injections of recPRAME + AS15 and all injections of dHER2 + AS15. No treatment‐related effects were observed for electrocardiography parameters. Mean fibrinogen levels were significantly higher in all treated groups compared to controls, but no differences could be observed at the end of the treatment‐free period. Transient but significant differences in biochemistry parameters were observed post‐injection: lower albumin/globulin ratios (p501 + AS15), and higher bilirubin, urea and creatinine (dHER2 + AS15). Pathology examinations revealed significant increases in axillary lymph node mean weights (recPRAME + AS15) compared to controls. A 100% seroconversion rate was observed in all treated groups, but not in controls. p501 protein expression was observed in prostates of all monkeys from studies assessing p501 + AS15. These results suggest a favorable safety profile of the AS15‐containing candidate vaccines, supporting the use of AS15 for clinical development of potential anticancer vaccines. Copyright © 2015 The Authors. Journal of Applied Toxicology Published by John Wiley & Sons Ltd. PMID:26032931

  10. Suspected acute coronary syndrome in the emergency room: Limited added value of heart type fatty acid binding protein point of care or ELISA tests: The FAME-ER (Fatty Acid binding protein in Myocardial infarction Evaluation in the Emergency Room) study.

    PubMed

    Bank, Ingrid Em; Dekker, Marieke S; Hoes, Arno W; Zuithoff, Nicolaas Pa; Verheggen, Peter Whm; de Vrey, Evelyn A; Wildbergh, Thierry X; Timmers, Leo; de Kleijn, Dominique Pv; Glatz, Jan Fc; Mosterd, Arend

    2016-08-01

    Timely recognition of acute coronary syndrome remains a challenge as many biomarkers, including troponin, remain negative in the first hours following the onset of chest pain. We assessed the diagnostic accuracy of heart-type fatty acid binding protein (H-FABP), a cardiac biomarker with potential value immediately post symptom onset. Prospective monocentre diagnostic accuracy study of H-FABP bedside point of care (CardioDetect®) and ELISA tests in acute coronary syndrome suspected patients presenting within 24 hours of symptom onset to the emergency department, in addition to clinical findings, electrocardiography and the currently recommended biomarker high sensitivity troponin-T (hs-cTnT). The final diagnosis of acute coronary syndrome was adjudicated by two independent cardiologists, blinded to H-FABP results. Acute coronary syndrome was diagnosed in 149 (32.9%) of 453 unselected patients with suspected acute coronary syndrome (56% men, mean age 62.6 years). Negative predictive values were similar for H-FABP point of care and ELISA tests (79% vs. 78% respectively), but inferior to initial hs-cTnT (negative predictive value 86%). The addition of H-FABP point of care results to hs-cTnT increased the negative predictive value to 89%. In a multivariable logistic regression model, H-FABP point of care and ELISA tests yielded relevant diagnostic information in addition to clinical findings and ECG (likelihood ratio test p<0.001) and increased area under the receiver operating characteristics curve (AUC; 0.82 vs. 0.84 and 0.84). This added value attenuated, however, after inclusion of hs-cTnT in the diagnostic model (AUC 0.88). In patients suspected of acute coronary syndrome presenting to the emergency department, H-FABP testing improves diagnostic accuracy in addition to clinical findings and electrocardiography. H-FABP, however, has no additional diagnostic value when hs-cTnT measurements are also available. © The European Society of Cardiology 2015.

  11. Single Doses up to 800 mg of E-52862 Do Not Prolong the QTc Interval--A Retrospective Validation by Pharmacokinetic-Pharmacodynamic Modelling of Electrocardiography Data Utilising the Effects of a Meal on QTc to Demonstrate ECG Assay Sensitivity.

    PubMed

    Täubel, Jörg; Ferber, Georg; Lorch, Ulrike; Wang, Duolao; Sust, Mariano; Camm, A John

    2015-01-01

    E-52862 is a Sigma-1 receptor antagonist (S1RA) currently under investigation as a potential analgesic medicine. We successfully applied a concentration-effect model retrospectively to a four-way crossover Phase I single ascending dose study and utilized the QTc shortening effects of a meal to demonstrate assay sensitivity by establishing the time course effects from baseline in all four periods, independently from any potential drug effects. Thirty two healthy male and female subjects were included in four treatment periods to receive single ascending doses of 500 mg, 600 mg or 800 mg of E-52862 or placebo. PK was linear over the dose range investigated and doses up to 600 mg were well tolerated. The baseline electrocardiography (ECG) measurements on Day-1 were time-matched with ECG and pharmacokinetic (PK) samples on Day 1 (dosing day). In this conventional mean change to time-matched placebo analysis, the largest time-matched difference to placebo QTcI was 1.44 ms (90% CI: -4.04, 6.93 ms) for 500 mg; -0.39 ms (90% CI: -3.91, 3.13 ms) for 600 mg and 1.32 ms (90% CI: -1.89, 4.53 ms) for 800 mg of E-52862, thereby showing the absence of any QTc prolonging effect at the doses tested. In addition concentration-effect models, one based on the placebo corrected change from baseline and one for the change of QTcI from average baseline with time as fixed effect were fitted to the data confirming the results of the time course analysis. The sensitivity of this study to detect small changes in the QTc interval was confirmed by demonstrating a shortening of QTcF of -8.1 (90% CI: -10.4, -5.9) one hour and -7.2 (90% CI: -9.4, -5.0) three hours after a standardised meal. EU Clinical Trials Register EudraCT 2010 020343 13.

  12. Inter-Rater Reliability and Downstream Financial Implications of Electrocardiography Screening in Young Athletes.

    PubMed

    Dhutia, Harshil; Malhotra, Aneil; Yeo, Tee Joo; Ster, Irina Chis; Gabus, Vincent; Steriotis, Alexandros; Dores, Helder; Mellor, Greg; García-Corrales, Carmen; Ensam, Bode; Jayalapan, Viknesh; Ezzat, Vivienne Anne; Finocchiaro, Gherardo; Gati, Sabiha; Papadakis, Michael; Tome-Esteban, Maria; Sharma, Sanjay

    2017-08-01

    Preparticipation screening for cardiovascular disease in young athletes with electrocardiography is endorsed by the European Society of Cardiology and several major sporting organizations. One of the concerns of the ECG as a screening test in young athletes relates to the potential for variation in interpretation. We investigated the degree of variation in ECG interpretation in athletes and its financial impact among cardiologists of differing experience. Eight cardiologists (4 with experience in screening athletes) each reported 400 ECGs of consecutively screened young athletes according to the 2010 European Society of Cardiology recommendations, Seattle criteria, and refined criteria. Cohen κ coefficient was used to calculate interobserver reliability. Cardiologists proposed secondary investigations after ECG interpretation, the costs of which were based on the UK National Health Service tariffs. Inexperienced cardiologists were more likely to classify an ECG as abnormal compared with experienced cardiologists (odds ratio, 1.44; 95% confidence interval, 1.03-2.02). Modification of ECG interpretation criteria improved interobserver reliability for categorizing an ECG as abnormal from poor (2010 European Society of Cardiology recommendations; κ=0.15) to moderate (refined criteria; κ=0.41) among inexperienced cardiologists; however, interobserver reliability was moderate for all 3 criteria among experienced cardiologists (κ=0.40-0.53). Inexperienced cardiologists were more likely to refer athletes for further evaluation compared with experienced cardiologists (odds ratio, 4.74; 95% confidence interval, 3.50-6.43) with poorer interobserver reliability (κ=0.22 versus κ=0.47). Interobserver reliability for secondary investigations after ECG interpretation ranged from poor to fair among inexperienced cardiologists (κ=0.15-0.30) and fair to moderate among experienced cardiologists (κ=0.21-0.46). The cost of cardiovascular evaluation per athlete was $175 (95% confidence interval, $142-$228) and $101 (95% confidence interval, $83-$131) for inexperienced and experienced cardiologists, respectively. Interpretation of the ECG in athletes and the resultant cascade of investigations are highly physician dependent even in experienced hands with important downstream financial implications, emphasizing the need for formal training and standardized diagnostic pathways. © 2017 American Heart Association, Inc.

  13. Novel Tool for Complete Digitization of Paper Electrocardiography Data

    PubMed Central

    Harless, Chris; Shah, Amit J.; Wick, Carson A.; Mcclellan, James H.

    2013-01-01

    Objective: We present a Matlab-based tool to convert electrocardiography (ECG) information from paper charts into digital ECG signals. The tool can be used for long-term retrospective studies of cardiac patients to study the evolving features with prognostic value. Methods and procedures: To perform the conversion, we: 1) detect the graphical grid on ECG charts using grayscale thresholding; 2) digitize the ECG signal based on its contour using a column-wise pixel scan; and 3) use template-based optical character recognition to extract patient demographic information from the paper ECG in order to interface the data with the patients' medical record. To validate the digitization technique: 1) correlation between the digital signals and signals digitized from paper ECG are performed and 2) clinically significant ECG parameters are measured and compared from both the paper-based ECG signals and the digitized ECG. Results: The validation demonstrates a correlation value of 0.85–0.9 between the digital ECG signal and the signal digitized from the paper ECG. There is a high correlation in the clinical parameters between the ECG information from the paper charts and digitized signal, with intra-observer and inter-observer correlations of 0.8–0.9 \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$({\\rm p}<{0.05})$\\end{document}, and kappa statistics ranging from 0.85 (inter-observer) to 1.00 (intra-observer). Conclusion: The important features of the ECG signal, especially the QRST complex and the associated intervals, are preserved by obtaining the contour from the paper ECG. The differences between the measures of clinically important features extracted from the original signal and the reconstructed signal are insignificant, thus highlighting the accuracy of this technique. Clinical impact: Using this type of ECG digitization tool to carry out retrospective studies on large databases, which rely on paper ECG records, studies of emerging ECG features can be performed. In addition, this tool can be used to potentially integrate digitized ECG information with digital ECG analysis programs and with the patient's electronic medical record. PMID:26594601

  14. The Acute Effects of Aerobic Exercise on Cognitive Flexibility and Task-Related Heart Rate Variability in Children With ADHD and Healthy Controls.

    PubMed

    Ludyga, Sebastian; Gerber, Markus; Mücke, Manuel; Brand, Serge; Weber, Peter; Brotzmann, Mark; Pühse, Uwe

    2018-02-01

    To investigate cognitive flexibility and task-related heart rate variability following moderately intense aerobic exercise and after watching a video in both children with ADHD and healthy controls. Using a cross-over design, participants completed cognitive assessments following exercise and a physically inactive control condition. Behavioral performance was assessed using the Alternate Uses task. Heart rate variability was recorded via electrocardiography during the cognitive task. The statistical analysis revealed that in comparison with the control condition, both groups showed higher cognitive flexibility following aerobic exercise. Moreover, decreased low frequency and high frequency power was observed in the exercise condition. The findings suggest that exercise elicits similar benefits for cognitive flexibility in children with ADHD and healthy controls, partly due to an increase in arousal induced by parasympathetic withdrawal.

  15. Asphyxia-activated corticocardiac signaling accelerates onset of cardiac arrest

    PubMed Central

    Li, Duan; Mabrouk, Omar S.; Liu, Tiecheng; Tian, Fangyun; Xu, Gang; Rengifo, Santiago; Choi, Sarah J.; Mathur, Abhay; Crooks, Charles P.; Kennedy, Robert T.; Wang, Michael M.; Ghanbari, Hamid; Borjigin, Jimo

    2015-01-01

    The mechanism by which the healthy heart and brain die rapidly in the absence of oxygen is not well understood. We performed continuous electrocardiography and electroencephalography in rats undergoing experimental asphyxia and analyzed cortical release of core neurotransmitters, changes in brain and heart electrical activity, and brain–heart connectivity. Asphyxia stimulates a robust and sustained increase of functional and effective cortical connectivity, an immediate increase in cortical release of a large set of neurotransmitters, and a delayed activation of corticocardiac functional and effective connectivity that persists until the onset of ventricular fibrillation. Blocking the brain’s autonomic outflow significantly delayed terminal ventricular fibrillation and lengthened the duration of detectable cortical activities despite the continued absence of oxygen. These results demonstrate that asphyxia activates a brainstorm, which accelerates premature death of the heart and the brain. PMID:25848007

  16. Ultraflexible organic amplifier with biocompatible gel electrodes.

    PubMed

    Sekitani, Tsuyoshi; Yokota, Tomoyuki; Kuribara, Kazunori; Kaltenbrunner, Martin; Fukushima, Takanori; Inoue, Yusuke; Sekino, Masaki; Isoyama, Takashi; Abe, Yusuke; Onodera, Hiroshi; Someya, Takao

    2016-04-29

    In vivo electronic monitoring systems are promising technology to obtain biosignals with high spatiotemporal resolution and sensitivity. Here we demonstrate the fabrication of a biocompatible highly conductive gel composite comprising multi-walled carbon nanotube-dispersed sheet with an aqueous hydrogel. This gel composite exhibits admittance of 100 mS cm(-2) and maintains high admittance even in a low-frequency range. On implantation into a living hypodermal tissue for 4 weeks, it showed a small foreign-body reaction compared with widely used metal electrodes. Capitalizing on the multi-functional gel composite, we fabricated an ultrathin and mechanically flexible organic active matrix amplifier on a 1.2-μm-thick polyethylene-naphthalate film to amplify (amplification factor: ∼200) weak biosignals. The composite was integrated to the amplifier to realize a direct lead epicardial electrocardiography that is easily spread over an uneven heart tissue.

  17. Comparison of the Extended Kalman Filter and the Unscented Kalman Filter for Magnetocardiography activation time imaging

    NASA Astrophysics Data System (ADS)

    Ahrens, H.; Argin, F.; Klinkenbusch, L.

    2013-07-01

    The non-invasive and radiation-free imaging of the electrical activity of the heart with Electrocardiography (ECG) or Magnetocardiography (MCG) can be helpful for physicians for instance in the localization of the origin of cardiac arrhythmia. In this paper we compare two Kalman Filter algorithms for the solution of a nonlinear state-space model and for the subsequent imaging of the activation/depolarization times of the heart muscle: the Extended Kalman Filter (EKF) and the Unscented Kalman Filter (UKF). The algorithms are compared for simulations of a (6×6) magnetometer array, a torso model with piecewise homogeneous conductivities, 946 current dipoles located in a small part of the heart (apex), and several noise levels. It is found that for all tested noise levels the convergence of the activation times is faster for the UKF.

  18. State of the art techniques for preservation and reuse of hard copy electrocardiograms.

    PubMed

    Lobodzinski, Suave M; Teppner, Ulrich; Laks, Michael

    2003-01-01

    Baseline examinations and periodic reexaminations in longitudinal population studies, together with ongoing surveillance for morbidity and mortality, provide unique opportunities for seeking ways to enhance the value of electrocardiography (ECG) as an inexpensive and noninvasive tool for prognosis and diagnosis. We used newly developed optical ECG waveform recognition (OEWR) technique capable of extracting raw waveform data from legacy hard copy ECG recording. Hardcopy ECG recordings were scanned and processed by the OEWR algorithm. The extracted ECG datasets were formatted into a newly proposed, vendor-neutral, ECG XML data format. Oracle database was used as a repository for ECG records in XML format. The proposed technique for XML encapsulation of OEWR processed hard copy records resulted in an efficient method for inclusion of paper ECG records into research databases, thus providing their preservation, reuse and accession.

  19. Characterization of physiological networks in sleep apnea patients using artificial neural networks for Granger causality computation

    NASA Astrophysics Data System (ADS)

    Cárdenas, Jhon; Orjuela-Cañón, Alvaro D.; Cerquera, Alexander; Ravelo, Antonio

    2017-11-01

    Different studies have used Transfer Entropy (TE) and Granger Causality (GC) computation to quantify interconnection between physiological systems. These methods have disadvantages in parametrization and availability in analytic formulas to evaluate the significance of the results. Other inconvenience is related with the assumptions in the distribution of the models generated from the data. In this document, the authors present a way to measure the causality that connect the Central Nervous System (CNS) and the Cardiac System (CS) in people diagnosed with obstructive sleep apnea syndrome (OSA) before and during treatment with continuous positive air pressure (CPAP). For this purpose, artificial neural networks were used to obtain models for GC computation, based on time series of normalized powers calculated from electrocardiography (EKG) and electroencephalography (EEG) signals recorded in polysomnography (PSG) studies.

  20. Open Access Integrated Therapeutic and Diagnostic Platforms for Personalized Cardiovascular Medicine

    PubMed Central

    Gladding, Patrick A.; Cave, Andrew; Zareian, Mehran; Smith, Kevin; Hussan, Jagir; Hunter, Peter; Erogbogbo, Folarin; Aguilar, Zoraida; Martin, David S.; Chan, Eugene; Homer, Margie L.; Shevade, Abhijit V.; Kassemi, Mohammad; Thomas, James D.; Schlegel, Todd T.

    2013-01-01

    It is undeniable that the increasing costs in healthcare are a concern. Although technological advancements have been made in healthcare systems, the return on investment made by governments and payers has been poor. The current model of care is unsustainable and is due for an upgrade. In developed nations, a law of diminishing returns has been noted in population health standards, whilst in the developing world, westernized chronic illnesses, such as diabetes and cardiovascular disease have become emerging problems. The reasons for these trends are complex, multifactorial and not easily reversed. Personalized medicine has the potential to have a significant impact on these issues, but for it to be truly successful, interdisciplinary mass collaboration is required. We propose here a vision for open-access advanced analytics for personalized cardiac diagnostics using imaging, electrocardiography and genomics. PMID:25562653

  1. Non-invasive hypoglycemia monitoring system using extreme learning machine for Type 1 diabetes.

    PubMed

    Ling, Sai Ho; San, Phyo Phyo; Nguyen, Hung T

    2016-09-01

    Hypoglycemia is a very common in type 1 diabetic persons and can occur at any age. It is always threatening to the well-being of patients with Type 1 diabetes mellitus (T1DM) since hypoglycemia leads to seizures or loss of consciousness and the possible development of permanent brain dysfunction under certain circumstances. Because of that, an accurate continuing hypoglycemia monitoring system is a very important medical device for diabetic patients. In this paper, we proposed a non-invasive hypoglycemia monitoring system using the physiological parameters of electrocardiography (ECG) signal. To enhance the detection accuracy, extreme learning machine (ELM) is developed to recognize the presence of hypoglycemia. A clinical study of 16 children with T1DM is given to illustrate the good performance of ELM. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  2. A Comprehensive Ubiquitous Healthcare Solution on an Android™ Mobile Device

    PubMed Central

    Hii, Pei-Cheng; Chung, Wan-Young

    2011-01-01

    Provision of ubiquitous healthcare solutions which provide healthcare services at anytime anywhere has become more favorable nowadays due to the emphasis on healthcare awareness and also the growth of mobile wireless technologies. Following this approach, an Android™ smart phone device is proposed as a mobile monitoring terminal to observe and analyze ECG (electrocardiography) waveforms from wearable ECG devices in real time under the coverage of a wireless sensor network (WSN). The exploitation of WSN in healthcare is able to substitute the complicated wired technology, moving healthcare away from a fixed location setting. As an extension to the monitoring scheme, medicine care is taken into consideration by utilizing the mobile phone as a barcode decoder, to verify and assist out-patients in the medication administration process, providing a better and more comprehensive healthcare service. PMID:22163986

  3. ECG by mobile technologies.

    PubMed

    Guzik, Przemyslaw; Malik, Marek

    Mobile electrocardiographs consist of three components: a mobile device (e.g. a smartphone), an electrocardiographic device or accessory, and a mobile application. Mobile platforms are small computers with sufficient computational power, good quality display, suitable data storage, and several possibilities of data transmission. Electrocardiographic electrodes and sensors for mobile use utilize unconventional materials, e.g. rubber, e-textile, and inkjet-printed nanoparticle electrodes. Mobile devices can be handheld, worn as vests or T-shirts, or attached to patient's skin as biopatches. Mobile electrocardiographic devices and accessories may additionally record other signals including respiratory rate, activity level, and geolocation. Large-scale clinical studies that utilize electrocardiography are easier to conduct using mobile technologies and the collected data are suitable for "big data" processing. This is expected to reveal phenomena so far inaccessible by standard electrocardiographic techniques. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Ambulatory electrocardiography in car workers.

    PubMed Central

    Baxter, P J; White, W G; Barnes, G M; Cashman, P M

    1978-01-01

    A previous study in a car assembly plant showed that production-line workers had a lower incidence rate of heart attacks than executive staff. In the present study some major coronary risk factors and 24-hour ambulatory electrocardiograms were investigated in two age-matched samples of 30 middle-aged men drawn from these occupations. Men with a known history of heart disease were excluded. Compared with production-line workers, executive staff on average had a higher diastolic blood pressure (P less than 0.05) and fewer took heavy exercise during their leisure time (P less than 0.05). Ventricular premature beats (VPB was also similar for each of the periods of work, leisure and sleep. Apart from isolated ectopic beats, disturbances of rhythm were uncommon, and neither VPB nor other arrhythmias appeared to be induced by occupational factors. PMID:656344

  5. Experimental characterization and analysis of the BITalino platforms against a reference device.

    PubMed

    Batista, Diana; Silva, Hugo; Fred, Ana

    2017-07-01

    Low-cost hardware platforms for biomedical engineering are becoming increasingly available, which empower the research community in the development of new projects in a wide range of areas related with physiological data acquisition. Building upon previous work by our group, this work compares the quality of the data acquired by means of two different versions of the multimodal physiological computing platform BITalino, with a device that can be considered a reference. We acquired data from 5 sensors, namely Accelerometry (ACC), Electrocardiography (ECG), Electroencephalography (EEG), Electrodermal Activity (EDA) and Electromyography (EMG). Experimental evaluation shows that ACC, ECG and EDA data are highly correlated with the reference in what concerns the raw waveforms. When compared by means of their commonly used features, EEG and EMG data are also quite similar across the different devices.

  6. Rare case of left-dominant arrhythmogenic right ventricular cardiomyopathy with dramatic reverse remodeling after cardiac resynchronization as an adjunct to pharmacological therapy.

    PubMed

    Hsiao, Chih-Chung; Kuo, Jen-Yuan; Yun, Chun-Ho; Hung, Chung-Lieh; Tsai, Cheng-Ho; Yeh, Hung-I

    2012-01-01

    A 57-year-old man presented with near syncope and hemodynamic compromise after exercise. A sustained ventricular tachycardia (VT) of right bundle-branch block morphology was evident upon examination at our emergency department. Baseline 12-lead electrocardiography revealed a sinus rhythm with a complete left bundle-branch block after successful cardioversion of the VT. Coronary angiography revealed patent coronary arteries, whereas left ventriculography demonstrated impaired systolic function, accompanied by a peculiar basal lateral aneurysm. Both echocardiography and magnetic resonance imaging were consistent with a diagnosis of left-dominant arrhythmogenic right ventricular cardiomyopathy. Four months later, substantial ventricular reverse remodeling and clinical improvements were observed after cardiac resynchronization therapy with a defibrillator, as an adjunct to conventional pharmacological therapy. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. The dilemma of an incidental preoperative electrocardiogram showing a Brugada phenotype.

    PubMed

    Welman, Kiera; Matloob, Samir; Dubrey, Simon William; Elliott, Perry

    2011-08-31

    A Brugada pattern on routine electrocardiography is one of several features that can indicate the potential for life threatening rhythm disturbances. The authors describe such a scenario in an asymptomatic 38-year-old woman who required significant surgery under anaesthesia. The diagnosis and possible management routes are outlined with an emphasis on the incumbent psychosocial and familial issues that are encountered. The patient underwent her surgery and was then further investigated to 'prove' the diagnosis. Ultimately, the patient declined further investigations and interventions. This case highlights the dilemma faced by anaesthetists and clinicians, not to mention the patients and their family when a Brugada phenotype is identified on a routine ECG. Clinicians should seek an expert opinion but ultimately, as in this case, the patient should be positioned to make an informed decision on what route to follow.

  8. Recommendations for the standardization and interpretation of the electrocardiogram. Part I: The electrocardiogram and its technology. A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society.

    PubMed

    Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S

    2007-03-01

    This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.

  9. Pragmatic approach to chest pain patients discharged with undetectable high-sensitivity troponin T and normal electrocardiogram: the STABS + CT protocol.

    PubMed

    Bishop, Warrick; Girao, Gary

    2017-06-01

    A strategy that discharges chest pain patients with negative high-sensitivity troponin and non-ischaemic electrocardiography changes may still result in 0.44% of patients experiencing myocardial infarction within 30 days. We observed that a pragmatic approach that systematically discharged 25 patients on cardio-protective medications of aspirin, metoprolol and atorvastatin followed with prompt (<10 days) coronary computed tomography angiography resulted in no major adverse cardiac event and adverse drug reaction 30 days post-presentation. The strategy resulted in three patients (12%) ultimately diagnosed with likely unstable angina, which required planned coronary intervention in two patients and medical management in one patient. No unplanned readmissions for chest pains were noted from initial presentation through to 6-month follow up. © 2017 Royal Australasian College of Physicians.

  10. A harmonic linear dynamical system for prominent ECG feature extraction.

    PubMed

    Thi, Ngoc Anh Nguyen; Yang, Hyung-Jeong; Kim, SunHee; Do, Luu Ngoc

    2014-01-01

    Unsupervised mining of electrocardiography (ECG) time series is a crucial task in biomedical applications. To have efficiency of the clustering results, the prominent features extracted from preprocessing analysis on multiple ECG time series need to be investigated. In this paper, a Harmonic Linear Dynamical System is applied to discover vital prominent features via mining the evolving hidden dynamics and correlations in ECG time series. The discovery of the comprehensible and interpretable features of the proposed feature extraction methodology effectively represents the accuracy and the reliability of clustering results. Particularly, the empirical evaluation results of the proposed method demonstrate the improved performance of clustering compared to the previous main stream feature extraction approaches for ECG time series clustering tasks. Furthermore, the experimental results on real-world datasets show scalability with linear computation time to the duration of the time series.

  11. Cardiovascular effects of SPARK conducted electrical weapon in healthy subjects.

    PubMed

    Scherr, Carlos; de Carvalho, Antonio Carlos; Belem, Luciano Juaçaba; Loyola, Luiz Henrique; Guerra, Renata Leborato; Blanco, Fernanda; Mangia, Claudio

    2016-12-15

    The increasing use of conducted electronic weapons (CEW) cause concern regarding its secure application, specially regarding the implications in the cardiovascular system. The objective was to determine Spark CEW safety through cardiovascular parameters analysis of healthy volunteers subjected to its use. Volunteers over 18years without cardiovascular disease or recent use of illegal drugs were submitted, before and after being affected with Spark CEW, to clinical evaluation; blood collection for serum laboratory tests; transthoracic electrocardiography at rest, transthoracic echodopplercardiogram and 24hour Holter. All 71 patients reported being incapable of any voluntary reaction during the shock of the application time. No arrhythmia or myocardial necrosis was related to the use of non-lethal weapon SPARK. Reported adverse events were self-limited, and mostly mild. SPARK brand CEW is effective in incapacitating individuals by the shock of the application time, without causing. Copyright © 2016. Published by Elsevier Ireland Ltd.

  12. QRS classification and spatial combination for robust heart rate detection in low-quality fetal ECG recordings.

    PubMed

    Warmerdam, G; Vullings, R; Van Pul, C; Andriessen, P; Oei, S G; Wijn, P

    2013-01-01

    Non-invasive fetal electrocardiography (ECG) can be used for prolonged monitoring of the fetal heart rate (FHR). However, the signal-to-noise-ratio (SNR) of non-invasive ECG recordings is often insufficient for reliable detection of the FHR. To overcome this problem, source separation techniques can be used to enhance the fetal ECG. This study uses a physiology-based source separation (PBSS) technique that has already been demonstrated to outperform widely used blind source separation techniques. Despite the relatively good performance of PBSS in enhancing the fetal ECG, PBSS is still susceptible to artifacts. In this study an augmented PBSS technique is developed to reduce the influence of artifacts. The performance of the developed method is compared to PBSS on multi-channel non-invasive fetal ECG recordings. Based on this comparison, the developed method is shown to outperform PBSS for the enhancement of the fetal ECG.

  13. Persistent tachycardia in clozapine treated patients: A 24-hour ambulatory electrocardiogram study.

    PubMed

    Nilsson, Björn M; Lindström, Leif; Mohsen, Issam; Holmlöv, Karolina; Bodén, Robert

    2018-03-27

    Tachycardia is associated with cardiovascular mortality. Tachycardia is also a known clozapine adverse effect. However, whether clozapine-associated tachycardia is persistent is not known. Thirty clozapine-treated patients with clinical tachycardia were investigated with 24-hour ambulatory electrocardiography (ECG). Baseline peripheral heart rate (HR) was 106.7±7.8. The ambulatory ECG 24-hour-HR was 98.7±9.7. Baseline HR and 24-hour-HR correlated strongly (r=0.74, p=0.000003). Daytime HR was 106.4±9.9 and nighttime HR 89.2±12.0. Low dose bisoprolol reduced HR significantly. The high 24-hour-HR indicates a persistent tachycardia. Tachycardia should not discourage from clozapine use but the findings indicate a need of guidelines for detection and treatment of clozapine-associated tachycardia. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review

    NASA Astrophysics Data System (ADS)

    Yao, Shanshan; Zhu, Yong

    2016-04-01

    Long-term, continuous, and unsupervised tracking of physiological data is becoming increasingly attractive for health/wellness monitoring and ailment treatment. Nanomaterials have recently attracted extensive attention as building blocks for flexible/stretchable conductors and are thus promising candidates for electrophysiological electrodes. Here we provide a review on nanomaterial-enabled dry electrodes for electrophysiological sensing, focusing on electrocardiography (ECG). The dry electrodes can be classified into contact surface electrodes, contact-penetrating electrodes, and noncontact capacitive electrodes. Different types of electrodes including their corresponding equivalent electrode-skin interface models and the sources of the noise are first introduced, followed by a review on recent developments of dry ECG electrodes based on various nanomaterials, including metallic nanowires, metallic nanoparticles, carbon nanotubes, and graphene. Their fabrication processes and performances in terms of electrode-skin impedance, signal-to-noise ratio, resistance to motion artifacts, skin compatibility, and long-term stability are discussed.

  15. Short-term minoxidil use associated with pericardial effusion and cardiac tamponade: an uncommon presentation.

    PubMed

    Pasala, Krishna K; Gujja, Karthik; Prabhu, Hejmadi; Vasavada, Balendu; Konka, Sudarsanam

    2012-11-01

    A 48-year-old man presented with complaints of shortness of breath and lower extremity swelling. His medical history was significant for hypertension on minoxidil and recent intracerebellar hemorrhage. Electrocardiography showed sinus tachycardia with left ventricular hypertrophy, and cardiomegaly was noted in the chest x-ray. The patient was hypertensive and tachypneic on admission. An echocardiogram taken immediately showed a large pericardial effusion with evidence of cardiac tamponade. He underwent immediate pericardiocentesis with drainage of 900 mL of pericardial fluid with significant improvement in the symptoms. Analysis of the pericardial fluid proved to be nondiagnostic. Infectious and rheumatologic causes were ruled out. After an extensive battery of tests, not yielding any diagnostic results, the pericardial effusion was attributed to minoxidil therapy. Closer monitoring is needed to prevent potentially fatal complications such as cardiac tamponade as in our patient.

  16. Myotonic Dystrophy Initially Presenting as Tachycardiomyopathy Successful Catheter Ablation of Atrial Flutter

    PubMed Central

    Asbach, S.; Gutleben, K. J.; Dahlem, P.; Brachmann, J.; Nölker, G.

    2010-01-01

    Myotonic dystrophy is a genetic muscular disease that is frequently associated with cardiac arrhythmias. Bradyarrhythmias, such as sinus bradycardia and atrioventricular block, are more common than tachyarrhythmias. Rarely, previously undiagnosed patients with myotonic dystrophy initially present with a tachyarrhythmia. We describe the case of a 14-year-old boy, who was admitted to the hospital with clinical signs and symptoms of decompensated heart failure and severely reduced left ventricular function. Electrocardiography showed common-type atrial flutter with 2 : 1 conduction resulting in a heart rate of 160 bpm. Initiation of medical therapy for heart failure as well as electrical cardioversion led to a marked clinical improvement. Catheter ablation of atrial flutter was performed to prevent future cardiac decompensations and to prevent development of tachymyopathy. Left ventricular function normalized during followup. Genetic analysis confirmed the clinical suspicion of myotonic dystrophy as known in other family members in this case. PMID:20871860

  17. Toward Hypertension Prediction Based on PPG-Derived HRV Signals: a Feasibility Study.

    PubMed

    Lan, Kun-Chan; Raknim, Paweeya; Kao, Wei-Fong; Huang, Jyh-How

    2018-04-21

    Heart rate variability (HRV) is often used to assess the risk of cardiovascular disease, and data on this can be obtained via electrocardiography (ECG). However, collecting heart rate data via photoplethysmography (PPG) is now a lot easier. We investigate the feasibility of using the PPG-based heart rate to estimate HRV and predict diseases. We obtain three months of PPG-based heart rate data from subjects with and without hypertension, and calculate the HRV based on various forms of time and frequency domain analysis. We then apply a data mining technique to this estimated HRV data, to see if it is possible to correctly identify patients with hypertension. We use six HRV parameters to predict hypertension, and find SDNN has the best predictive power. We show that early disease prediction is possible through collecting one's PPG-based heart rate information.

  18. Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC/D): A Systematic Literature Review

    PubMed Central

    Romero, Jorge; Mejia-Lopez, Eliany; Manrique, Carlos; Lucariello, Richard

    2013-01-01

    Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is a genetic form of cardiomyopathy (CM) usually transmitted with an autosomal dominant pattern. It primary affects the right ventricle (RV), but may involve the left ventricle (LV) and culminate in biventricular heart failure (HF), life threatening ventricular arrhythmias and sudden cardiac death (SCD). It accounts for 11%–22% of cases of SCD in the young athlete population. Pathologically is characterized by myocardial atrophy, fibrofatty replacement and chamber dilation. Diagnosis is often difficult due to the nonspecific nature of the disease and the broad spectrum of phenotypic variations. Therefore consensus diagnostic criteria have been developed and combined electrocardiography, echocardiography, cardiac magnetic resonance imaging (CMRI) and myocardial biopsy. Early detection, family screening and risk stratification are the cornerstones in the diagnostic evaluation. Implantable cardioverter-defibrillator (ICD) implantation, ablative procedures and heart transplantation are currently the main therapeutic options. PMID:23761986

  19. Wavelet approach to artifact noise removal from Capacitive coupled Electrocardiograph.

    PubMed

    Lee, Seung Min; Kim, Ko Keun; Park, Kwang Suk

    2008-01-01

    Capacitive coupled Electrocardiography (ECG) is introduced as non-invasive measurement technology for ubiquitous health care and appliance are spread out widely. Although it has many merits, however, capacitive coupled ECG is very weak for motion artifacts for its non-skin-contact property. There are many studies for artifact problems which treats all artifact signals below 0.8Hz. In our capacitive coupled ECG measurement system, artifacts exist not only below 0.8Hz but also over than 10Hz. Therefore, artifact noise removal algorithm using wavelet method is tested to reject artifact-wandered signal from measured signals. It is observed that using power calculation each decimation step, artifact-wandered signal is removed as low frequency artifacts as high frequency artifacts. Although some original ECG signal is removed with artifact signal, we could level the signal quality for long term measure which shows the best quality ECG signals as we can get.

  20. ["Habitual" left branch block alternating with 2 "disguised" bracnch block].

    PubMed

    Lévy, S; Jullien, G; Mathieu, P; Mostefa, S; Gérard, R

    1976-10-01

    Two cases of alternating left bundle branch block and "masquerading block" (with left bundle branch morphology in the stnadard leads and right bundle branch block morphology in the precordial leads) were studied by serial tracings and his bundle electrocardiography. In case 1 "the masquerading" block was associated with a first degree AV block related to a prolongation of HV interval. This case is to our knowledge the first cas of alternating bundle branch block in which his bundle activity was recorded in man. In case 2, the patient had atrial fibrilation and His bundle recordings were performed while differents degrees of left bundle branch block were present: The mechanism of the alternation and the concept of "masquerading" block are discussed. It is suggested that this type of block represents a right bundle branch block associated with severe lesions of the "left system".

  1. Design and Development of Non-Contact Bio-Potential Electrodes for Pervasive Health Monitoring Applications.

    PubMed

    Portelli, Anthony J; Nasuto, Slawomir J

    2017-01-01

    For the advent of pervasive bio-potential monitoring, it will be necessary to utilize a combination of cheap, quick to apply, low-noise electrodes and compact electronics with wireless technologies. Once available, all electrical activity resulting from the processes of the human body could be actively and constantly monitored without the need for cumbersome application and maintenance. This could significantly improve the early diagnosis of a range of different conditions in high-risk individuals, opening the possibility for new treatments and interventions as conditions develop. This paper presents the design and implementation of compact, non-contact capacitive bio-potential electrodes utilising a low impedance current-to-voltage configuration and a bootstrapped voltage follower, demonstrating results applicable to research applications for capacitive electrocardiography and capacitive electromyography. The presented electrodes use few components, have a small surface area and are capable of acquiring a range of bio-potential signals.

  2. Multiple bio-monitoring system using visible light for electromagnetic-wave free indoor healthcare

    NASA Astrophysics Data System (ADS)

    An, Jinyoung; Pham, Ngoc Quan; Chung, Wan-Young

    2017-12-01

    In this paper, a multiple biomedical data transmission system with visible light communication (VLC) is proposed for an electromagnetic-wave-free indoor healthcare. VLC technology has emerged as an alternative solution to radio-frequency (RF) wireless systems, due to its various merits, e.g., ubiquity, power efficiency, no RF radiation, and security. With VLC, critical bio-medical signals, including electrocardiography (ECG), can be transmitted in places where RF radiation is restricted. This potential advantage of VLC could save more lives in emergency situations. A time hopping (TH) scheme is employed to transfer multiple medical-data streams in real time with a simple system design. Multiple data streams are transmitted using identical color LEDs and go into an optical detector. The received multiple data streams are demodulated and rearranged using a TH-based demodulator. The medical data is then monitored and managed to provide the necessary medical care for each patient.

  3. Wavelet-based watermarking and compression for ECG signals with verification evaluation.

    PubMed

    Tseng, Kuo-Kun; He, Xialong; Kung, Woon-Man; Chen, Shuo-Tsung; Liao, Minghong; Huang, Huang-Nan

    2014-02-21

    In the current open society and with the growth of human rights, people are more and more concerned about the privacy of their information and other important data. This study makes use of electrocardiography (ECG) data in order to protect individual information. An ECG signal can not only be used to analyze disease, but also to provide crucial biometric information for identification and authentication. In this study, we propose a new idea of integrating electrocardiogram watermarking and compression approach, which has never been researched before. ECG watermarking can ensure the confidentiality and reliability of a user's data while reducing the amount of data. In the evaluation, we apply the embedding capacity, bit error rate (BER), signal-to-noise ratio (SNR), compression ratio (CR), and compressed-signal to noise ratio (CNR) methods to assess the proposed algorithm. After comprehensive evaluation the final results show that our algorithm is robust and feasible.

  4. Coronary heart disease index based on longitudinal electrocardiography

    NASA Technical Reports Server (NTRS)

    Townsend, J. C.; Cronin, J. P.

    1977-01-01

    A coronary heart disease index was developed from longitudinal ECG (LCG) tracings to serve as a cardiac health measure in studies of working and, essentially, asymptomatic populations, such as pilots and executives. For a given subject, the index consisted of a composite score based on the presence of LCG aberrations and weighted values previously assigned to them. The index was validated by correlating it with the known presence or absence of CHD as determined by a complete physical examination, including treadmill, resting ECG, and risk factor information. The validating sample consisted of 111 subjects drawn by a stratified-random procedure from 5000 available case histories. The CHD index was found to be significantly more valid as a sole indicator of CHD than the LCG without the use of the index. The index consistently produced higher validity coefficients in identifying CHD than did treadmill testing, resting ECG, or risk factor analysis.

  5. Integration of Wearable Solutions in AAL Environments with Mobility Support.

    PubMed

    Costa, Susana E P; Rodrigues, Joel J P C; Silva, Bruno M C; Isento, João N; Corchado, Juan M

    2015-12-01

    The overall demographic profile of current societies point to a significant growth of the elderly people. Associated with the increase of the average hope of life and consequent increase in chronic diseases, there is the need for protection and daily care. Increasing investments in technology, such as Ambient Assisted Living (AAL) solutions, promote the quality of live extending the time people can live in their desired environment. This paper proposes the design, deployment, and real testbed of an e-health wearable monitoring system based on the integration of several AAL tools and platforms for elderly's bio-signals monitoring. This solution includes electrocardiography (ECG), respiration rate, beats per minute, body temperature, and falls detention and notification. The paper also describes, in detail, the real pilot and analyzes some early results concerning the users quality of experience, and the found results are very promising.

  6. Cardiovascular dynamics during the initial period of head-down tilt

    NASA Technical Reports Server (NTRS)

    Tomaselli, Clare Marie; Kenney, Richard A.; Frey, Mary Anne Bassett; Hoffler, G. Wyckliffe

    1987-01-01

    The cardiovascular response to 1 h of 60-deg head-down tilt was studied in 12 male subjects, ages 30-39 years, to simulate the early effects of weightlessness. Fluid shifts, hemodynamic variables, and indices of myocardial contractility were evaluated by utilizing electrocardiography, systolic time intervals, impedance cardiography, sphygmomanometry, and measurement of calf circumference. Most cardiovascular variables remained stable throughout the initial 30 min of the protocol, even though translocation of fluid from the legs to the thorax commenced immediately with the onset of head-down tilt. In contrast, minutes 30-60 were characterized by reduced stroke volume, cardiac output, mean stroke ejection rate, and Heather index concomitant with an elevation in mean arterial pressure. Intrathoracic fluid volume continued to increase, while leg volume continued to decrease. This latter physiological response suggests intrathoracic sequestration of fluid volume; blood was apparently redistributed to the pulmonary circulation rather than being retained in the great veins.

  7. Effect of a central redistribution of fluid volume on response to lower-body negative pressure

    NASA Technical Reports Server (NTRS)

    Tomaselli, Clare M.; Frey, Mary A. B.; Kenney, Richard A.; Hoffler, G. Wyckliffe

    1990-01-01

    Cardiovascular responses to lower-body negative pressure (LBNP) were studied following 1 hour of 6-deg head-down tilt to determine whether a redistribution of blood volume toward the central circulation modifies the subsequent response to orthostatic stress. Responses of 12 men, ages 30-39 years, were evaluated by electrocardiography, impedance cardiography, sphygmomanometry, and measurement of calf circumference. During the LBNP that followed head-down tilt, as compared with control LBNP (no preceding head-down tilt) subjects, had smaller stroke volume and cardiac output, greater total peripheral resistance, and less calf enlargement. These differences reflect differences in the variables immediately preceding LBNP. Magnitudes of the responses from pre-LBNP to each pressure stage of the LBNP procedure did not differ between protocols. Mean and diastolic arterial pressures were slightly elevated after LBNP-control, but they fell slightly during LBNP post-tilt.

  8. Cardiovascular Assessment of Falls in Older People

    PubMed Central

    Tan, Maw Pin; Kenny, Rose Anne

    2006-01-01

    Falls in older people can be caused by underlying cardiovascular disorders, either because of balance instability in persons with background gait and balance disorders, or because of amnesia for loss of consciousness during unwitnessed syncope. Pertinent investigations include a detailed history, 12-lead electrocardiography, lying and standing blood pressure, carotid sinus massage (CSM), head-up tilt, cardiac electrophysiological tests, and ambulatory blood pressure and heart rate monitoring, which includes external and internal cardiac monitoring. The presence of structural heart disease predicts an underlying cardiac cause. Conversely, the absence of either indicates that neurally mediated etiology is likely. CSM and tilt-table testing should be considered in patients with unexplained and recurrent falls. Holter monitoring over 24 hours has a low diagnostic yield. Early use of an implantable loop recorder may be more cost-effective. A dedicated investigation unit increases the likelihood of achieving positive diagnoses and significantly reduces hospital stay and health expenditure. PMID:18047258

  9. The Role of Echocardiography in Coronary Artery Disease and Acute Myocardial Infarction

    PubMed Central

    Esmaeilzadeh, Maryam; Parsaee, Mozhgan; Maleki, Majid

    2013-01-01

    Echocardiography is a non-invasive diagnostic technique which provides information regarding cardiac function and hemodynamics. It is the most frequently used cardiovascular diagnostic test after electrocardiography and chest X-ray. However, in a patient with acute chest pain, Transthoracic Echocardiography is essential both for diagnosing acute coronary syndrome, zeroing on the evaluation of ventricular function and the presence of regional wall motion abnormalities, and for ruling out other etiologies of acute chest pain or dyspnea, including aortic dissection and pericardial effusion. Echocardiography is a versatile imaging modality for the management of patients with chest pain and assessment of left ventricular systolic function, diastolic function, and even myocardial and coronary perfusion and is, therefore, useful in the diagnosis and triage of patients with acute chest pain or dyspnea. This review has focused on the current applications of echocardiography in patients with coronary artery disease and myocardial infarction. PMID:23646042

  10. Flow-gated radial phase-contrast imaging in the presence of weak flow.

    PubMed

    Peng, Hsu-Hsia; Huang, Teng-Yi; Wang, Fu-Nien; Chung, Hsiao-Wen

    2013-01-01

    To implement a flow-gating method to acquire phase-contrast (PC) images of carotid arteries without use of an electrocardiography (ECG) signal to synchronize the acquisition of imaging data with pulsatile arterial flow. The flow-gating method was realized through radial scanning and sophisticated post-processing methods including downsampling, complex difference, and correlation analysis to improve the evaluation of flow-gating times in radial phase-contrast scans. Quantitatively comparable results (R = 0.92-0.96, n = 9) of flow-related parameters, including mean velocity, mean flow rate, and flow volume, with conventional ECG-gated imaging demonstrated that the proposed method is highly feasible. The radial flow-gating PC imaging method is applicable in carotid arteries. The proposed flow-gating method can potentially avoid the setting up of ECG-related equipment for brain imaging. This technique has potential use in patients with arrhythmia or weak ECG signals.

  11. Design and Development of Non-Contact Bio-Potential Electrodes for Pervasive Health Monitoring Applications

    PubMed Central

    Portelli, Anthony J.; Nasuto, Slawomir J.

    2017-01-01

    For the advent of pervasive bio-potential monitoring, it will be necessary to utilize a combination of cheap, quick to apply, low-noise electrodes and compact electronics with wireless technologies. Once available, all electrical activity resulting from the processes of the human body could be actively and constantly monitored without the need for cumbersome application and maintenance. This could significantly improve the early diagnosis of a range of different conditions in high-risk individuals, opening the possibility for new treatments and interventions as conditions develop. This paper presents the design and implementation of compact, non-contact capacitive bio-potential electrodes utilising a low impedance current-to-voltage configuration and a bootstrapped voltage follower, demonstrating results applicable to research applications for capacitive electrocardiography and capacitive electromyography. The presented electrodes use few components, have a small surface area and are capable of acquiring a range of bio-potential signals. PMID:28045439

  12. Viable investigations and real-time recitation of enhanced ECG-based cardiac telemonitoring system for homecare applications: a systematic evaluation.

    PubMed

    Rajan, S Palanivel; Rajamony, Sukanesh

    2013-04-01

    A light and portable wireless biosignal retrieving system has always been a medical dream. This proposed wireless-type biosignal alerting system aims at designing and developing a module that detects the abnormal interpretations in the PQRST complex (electrocardiography) and heart rate of a patient in advance, gives a self-warning ring to the patient, and also sends a short message service warning to the doctor's mobile phone through the Global System for Mobile Communication. This system is a solution to supplement the limitations in conventional clinic examination such as the difficulty in capturing rare events, out-of-hospital monitoring of patients' heart status, and the immediate dissemination of the physician's instruction to the patient. These study results have immense consequence in researching, finding, and preventing epidemics in the cardiovascular system for the entire world.

  13. Seizure detection, seizure prediction, and closed-loop warning systems in epilepsy.

    PubMed

    Ramgopal, Sriram; Thome-Souza, Sigride; Jackson, Michele; Kadish, Navah Ester; Sánchez Fernández, Iván; Klehm, Jacquelyn; Bosl, William; Reinsberger, Claus; Schachter, Steven; Loddenkemper, Tobias

    2014-08-01

    Nearly one-third of patients with epilepsy continue to have seizures despite optimal medication management. Systems employed to detect seizures may have the potential to improve outcomes in these patients by allowing more tailored therapies and might, additionally, have a role in accident and SUDEP prevention. Automated seizure detection and prediction require algorithms which employ feature computation and subsequent classification. Over the last few decades, methods have been developed to detect seizures utilizing scalp and intracranial EEG, electrocardiography, accelerometry and motion sensors, electrodermal activity, and audio/video captures. To date, it is unclear which combination of detection technologies yields the best results, and approaches may ultimately need to be individualized. This review presents an overview of seizure detection and related prediction methods and discusses their potential uses in closed-loop warning systems in epilepsy. Copyright © 2014. Published by Elsevier Inc.

  14. Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society endorsed by the International Society for Computerized Electrocardiology.

    PubMed

    Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S; Josephson, Mark; Mason, Jay W; Okin, Peter; Surawicz, Borys; Wellens, Hein

    2007-03-13

    This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.

  15. Recommendations for the standardization and interpretation of the electrocardiogram: part I: The electrocardiogram and its technology: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: endorsed by the International Society for Computerized Electrocardiology.

    PubMed

    Kligfield, Paul; Gettes, Leonard S; Bailey, James J; Childers, Rory; Deal, Barbara J; Hancock, E William; van Herpen, Gerard; Kors, Jan A; Macfarlane, Peter; Mirvis, David M; Pahlm, Olle; Rautaharju, Pentti; Wagner, Galen S; Josephson, Mark; Mason, Jay W; Okin, Peter; Surawicz, Borys; Wellens, Hein

    2007-03-13

    This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.

  16. Design and implementation of a telemedicine system using Bluetooth protocol and GSM/GPRS network, for real time remote patient monitoring.

    PubMed

    Jasemian, Yousef; Nielsen, Lars Arendt

    2005-01-01

    This paper introduces the design and implementation of a generic wireless and Real-time Multi-purpose Health Care Telemedicine system applying Bluetooth protocol, Global System for Mobile Communications (GSM) and General Packet Radio Service (GPRS). The paper explores the factors that should be considered when evaluating different technologies for application in telemedicine system. The design and implementation of an embedded wireless communication platform utilising Bluetooth protocol is described, and the implementation problems and limitations are investigated. The system is tested and its telecommunication general aspects are verified. The results showed that the system has (97.9 +/- 1.3)% Up-time, 2.5 x 10(-5) Bit Error Rate, 1% Dropped Call Rate, 97.4% Call Success Rate, 5 second transmission delay in average, (3.42 +/- 0.11) kbps throughput, and the system may have application in electrocardiography.

  17. Ultraweak photon emission in the brain.

    PubMed

    Salari, V; Valian, H; Bassereh, H; Bókkon, I; Barkhordari, A

    2015-09-01

    Besides the low-frequency electromagnetic body-processes measurable through the electroencephalography (EEG), electrocardiography (ECG), etc. there are processes that do not need external excitation, emitting light within or close to the visible spectra. Such ultraweak photon emission (UPE), also named biophoton emission, reflects the cellular (and body) oxidative status. Recently, a growing body of evidence shows that UPE may play an important role in the basic functioning of living cells. Moreover, interesting evidences are beginning to emerge that UPE may well play an important role in neuronal functions. In fact, biophotons are byproducts in cellular metabolism and produce false signals (e.g., retinal discrete dark noise) but on the other side neurons contain many light sensitive molecules that makes it hard to imagine how they might not be influenced by UPE, and thus UPE may carry informational contents. Here, we investigate UPE in the brain from different points of view such as experimental evidences, theoretical modeling, and physiological significance.

  18. Heart rate variability and pain: associations of two interrelated homeostatic processes.

    PubMed

    Appelhans, Bradley M; Luecken, Linda J

    2008-02-01

    Between-person variability in pain sensitivity remains poorly understood. Given a conceptualization of pain as a homeostatic emotion, we hypothesized inverse associations between measures of resting heart rate variability (HRV), an index of autonomic regulation of heart rate that has been linked to emotionality, and sensitivity to subsequently administered thermal pain. Resting electrocardiography was collected, and frequency-domain measures of HRV were derived through spectral analysis. Fifty-nine right-handed participants provided ratings of pain intensity and unpleasantness following exposure to 4 degrees C thermal pain stimulation, and indicated their thresholds for barely noticeable and moderate pain during three exposures to decreasing temperature. Greater low-frequency HRV was associated with lower ratings of 4 degrees C pain unpleasantness and higher thresholds for barely noticeable and moderate pain. High-frequency HRV was unrelated to measures of pain sensitivity. Findings suggest pain sensitivity is influenced by characteristics of a central homeostatic system also involved in emotion.

  19. Ultraflexible organic amplifier with biocompatible gel electrodes

    PubMed Central

    Sekitani, Tsuyoshi; Yokota, Tomoyuki; Kuribara, Kazunori; Kaltenbrunner, Martin; Fukushima, Takanori; Inoue, Yusuke; Sekino, Masaki; Isoyama, Takashi; Abe, Yusuke; Onodera, Hiroshi; Someya, Takao

    2016-01-01

    In vivo electronic monitoring systems are promising technology to obtain biosignals with high spatiotemporal resolution and sensitivity. Here we demonstrate the fabrication of a biocompatible highly conductive gel composite comprising multi-walled carbon nanotube-dispersed sheet with an aqueous hydrogel. This gel composite exhibits admittance of 100 mS cm−2 and maintains high admittance even in a low-frequency range. On implantation into a living hypodermal tissue for 4 weeks, it showed a small foreign-body reaction compared with widely used metal electrodes. Capitalizing on the multi-functional gel composite, we fabricated an ultrathin and mechanically flexible organic active matrix amplifier on a 1.2-μm-thick polyethylene-naphthalate film to amplify (amplification factor: ∼200) weak biosignals. The composite was integrated to the amplifier to realize a direct lead epicardial electrocardiography that is easily spread over an uneven heart tissue. PMID:27125910

  20. A ZigBee-based wireless system for monitoring vital signs in hyperbaric chambers: Technical report.

    PubMed

    Carmona, Cristian; Alorda, Bartomeu; Gracia, Luis; Perez-Vidal, Carlos; Salinas, Antonio

    2017-01-01

    This paper presents the replacement of a traditional wired communication link of the hyperbaric chambers with a wireless ZigBee-based system. This move allows a reduction in the costs of seals capable of withstanding the internal pressures and gives rise to a more versatile system. The new system is able to capture and process individual vital signs like the electrocardiography signal, and other analog sources, sending the data to an external computer and allowing analysis, representation and sharing with medical staff. This system solves such problems as the attenuation of the signal produced by the metal walls of the hyperbaric chamber and has a coverage area large enough to manage up to six patients with an effective data rate conversion of 2kHz. Furthermore, a battery-based and multiparameter platform is designed for multipatient hyperbaric chambers. Copyright© Undersea and Hyperbaric Medical Society.

  1. Does the use of structured reporting improve usability? A comparative evaluation of the usability of two approaches for findings reporting in a large-scale telecardiology context.

    PubMed

    Lacerda, Thaisa Cardoso; von Wangenheim, Christiane Gresse; von Wangenheim, Aldo; Giuliano, Isabela

    2014-12-01

    One of the main reasons that leads to a low adoption rate of telemedicine systems is poor usability. An aspect that influences usability during the reporting of findings is the input mode, e.g., if a free-text (FT) or a structured report (SR) interface is employed. The objective of our study is to compare the usability of FT and ST telemedicine systems, specifically in terms of user satisfaction, efficiency and general usability. We comparatively evaluate the usability of these two input modes in a telecardiology system for issuing electrocardiography reports in the context of a statewide telemedicine system in Brazil with more than 350.000 performed tele-electrocardiography examinations. We adopted a multiple method research strategy, applying three different kinds of usability evaluations: user satisfaction was evaluated through interviews with seven medical professionals using the System Usability Scale (SUS) questionnaire and specific questions related to adequacy and user experience. Efficiency was evaluated by estimating execution time using the Keystroke-Level Model (KLM). General usability was assessed based on the conformity of the systems to a set of e-health specific usability heuristics. The results of this comparison provide a first indication that a structured report (SR) input mode for such a system is more satisfactory and efficient with a larger conformity to usability heuristics than free-text (FT) input. User satisfaction using the SUS questionnaire has been scored in average with 58.8 and 77.5 points for the FT and SR system, respectively, which means that the SR system was rated 18.65 points higher than the FT system. In terms of efficiency, the completion of a findings report using the SR mode is estimated to take 8.5s, 3.74 times faster than using the FT system (31.8s). The SR system also demonstrated less violations to usability heuristics (8 points) in comparison to 14 points observed in the FT system. These results provide a first indication that the usage of structured reporting as an input mode in telecardiology systems may enhance usability. This also seems to confirm the advantages of the usage of structured reporting, as already described in the literature for other areas such as teleradiology. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction

    PubMed Central

    2018-01-01

    Objective To compare radiation doses between conventional and chest pain protocols using dual-source retrospectively electrocardiography (ECG)-gated cardiothoracic computed tomography (CT) in children and adults and assess the effect of tube current saturation on radiation dose reduction. Materials and Methods This study included 104 patients (16.6 ± 7.7 years, range 5–48 years) that were divided into two groups: those with and those without tube current saturation. The estimated radiation doses of retrospectively ECG-gated spiral cardiothoracic CT were compared between conventional, uniphasic, and biphasic chest pain protocols acquired with the same imaging parameters in the same patients by using paired t tests. Dose reduction percentages, patient ages, volume CT dose index values, and tube current time products per rotation were compared between the two groups by using unpaired t tests. A p value < 0.05 was considered significant. Results The volume CT dose index values of the biphasic chest pain protocol (10.8 ± 3.9 mGy) were significantly lower than those of the conventional protocol (12.2 ± 4.7 mGy, p < 0.001) and those of the uniphasic chest pain protocol (12.9 ± 4.9 mGy, p < 0.001). The dose-saving effect of biphasic chest pain protocol was significantly less with a saturated tube current (4.5 ± 10.2%) than with unsaturated tube current method (14.8 ± 11.5%, p < 0.001). In 76 patients using 100 kVp, patient age showed no significant differences between the groups with and without tube current saturation in all protocols (p > 0.05); the groups with tube current saturation showed significantly higher volume CT dose index values (p < 0.01) and tube current time product per rotation (p < 0.001) than the groups without tube current saturation in all protocols. Conclusion The radiation dose of dual-source retrospectively ECG-gated spiral cardiothoracic CT can be reduced by approximately 15% by using the biphasic chest pain protocol instead of the conventional protocol in children and adults if radiation dose parameters are further optimized to avoid tube current saturation. PMID:29353996

  3. Wavelet-sparsity based regularization over time in the inverse problem of electrocardiography.

    PubMed

    Cluitmans, Matthijs J M; Karel, Joël M H; Bonizzi, Pietro; Volders, Paul G A; Westra, Ronald L; Peeters, Ralf L M

    2013-01-01

    Noninvasive, detailed assessment of electrical cardiac activity at the level of the heart surface has the potential to revolutionize diagnostics and therapy of cardiac pathologies. Due to the requirement of noninvasiveness, body-surface potentials are measured and have to be projected back to the heart surface, yielding an ill-posed inverse problem. Ill-posedness ensures that there are non-unique solutions to this problem, resulting in a problem of choice. In the current paper, it is proposed to restrict this choice by requiring that the time series of reconstructed heart-surface potentials is sparse in the wavelet domain. A local search technique is introduced that pursues a sparse solution, using an orthogonal wavelet transform. Epicardial potentials reconstructed from this method are compared to those from existing methods, and validated with actual intracardiac recordings. The new technique improves the reconstructions in terms of smoothness and recovers physiologically meaningful details. Additionally, reconstruction of activation timing seems to be improved when pursuing sparsity of the reconstructed signals in the wavelet domain.

  4. Non-contact and through-clothing measurement of the heart rate using ultrasound vibrocardiography.

    PubMed

    Jeger-Madiot, Nathan; Gateau, Jérôme; Fink, Mathias; Ing, Ros-Kiri

    2017-12-01

    We present a novel non-contact system for monitoring the heart rate on human subjects with clothes. Our approach is based on vibrocardiography, and measures locally skin displacements. Vibrocardiography with a laser Doppler vibrometer already allows monitoring of this vital sign, but can only be used on bare skin and requires an expensive piece of equipment. We propose here to use an airborne pulse-Doppler ultrasound system operating in the 20-60 kHz range, and comprised of an emitter focusing the ultrasound pulses on skin and a microphone recording the reflected waves. Our implementation was validated in vitro and on two healthy human subjects, using simultaneously laser vibrocardiography and electrocardiography as references. Accurate measurements of the heart rate on clothed skin suggest that our non-contact ultrasonic method could be implemented both inside and outside the clinical environment, and therefore benefit both medical and safety applications. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Electroretinography: A biopotential to assess the function/dysfunction of the retina

    NASA Astrophysics Data System (ADS)

    Quintana, Quinteros; Benedetto, M. L.; Maldonado, M. M.; de Payer E., A. C. Vera; Contin, M. A.

    2016-04-01

    The Electroretinography (ERG) is a noninvasive technique that allows the assessment of functional integrity of the retina. The ERG recordings are biopotencials acquired in the corneal surface as a response of retinal tissue against controlled light stimuli. In clinical ophthalmology ERG is not commonly used but nowadays, because of the high incidence of degenerative diseases of the retina (RD), its use should be increased. Like other biopotentials as electrocardiography (ECG), electroencephalogram (EEG) and electromyography (EMG), ERG is a low amplitude signal, in this case a few hundred of microvolts (µV), which must be fitted and processed. The ERG signals are affected in morphology in the presence of pathologies that affects the integrity of the different retinal cell groups, for example due to some RD. In advanced cases of RD recordings can be abolished in the time domain; and yet in them it is believed that there is relevant clinical information making the ERG a great potential diagnostic tool.

  6. Tele-electrocardiography in the epidemiological 'Study of Health in Pomerania' (SHIP).

    PubMed

    Alte, Dietrich; Völzke, Henry; Robinson, Daniel M; Kleine, Volker; Grabe, Hans Jörgen; John, Ulrich; Felix, Stephan B

    2006-01-01

    We have evaluated a portable electrocardiogram (ECG) card in the large population-based epidemiological 'Study of Health in Pomerania' (SHIP). In all, 7008 men and women (20-79 years) were randomly selected from population registries and 4310 subjects participated. Participants used an ECG card for four weeks and recorded two ECGs daily. The participants were also encouraged to record additional ECGs in the case of symptomatic arrhythmias, chest pain or dizziness. The ECGs were sent via telephone. Acrobat (.pdf) files arrived at the study centre via email. Arrhythmias were analysed by visual ECG inspection. Seventy-one per cent of the participants sent at least 80% of the requested ECGs for four weeks. There were few problems (about 70) in the total of 38,162 ECGs transmitted. Overall, 94% of all ECGs were rated as 'good'. Physicians required about 1.5 h to read approximately 100 ECGs daily. The functionality and ergonomics of ECG cards appear to be sufficiently developed for large-scale use in epidemiological studies.

  7. Triple electrical channels on a triple fluid swivel and its use to monitor intracranial temperature with a thermocouple.

    PubMed

    Parada, M A; Puig de Parada, M; Hernandez, L; Hoebel, B G

    1995-08-01

    A low-torque, bubble-free and multiple-channel fluid swivel of easy construction was recently described. This paper describes the design, construction and testing of 3 electrical channels added to the original fluid swivel. The new channels were tested monitoring intrahypothalamic temperature (T(hy)) by means of a copper-constantan thermocouple in freely moving rats, before and after a single intraperitoneal (i.p.) amphetamine injection (3 mg/kg). This test showed an increase in T(hy) after the injection and the maintenance of the electrical continuity along the whole testing period, even when the animals were hyperactive. With this improvement the original swivel was transformed in a more versatile device for experiments requiring fluid handlings and electrophysiological manipulations. Electrical stimulation as in kindling or brain self-stimulation, and electrophysiological recordings as in electroencephalography, electromiography, electrocardiography, in vivo voltammetry and even neuronal unit recording, are just examples of the electrophysiological methods that can be combined with drug self-administration and microdialysis using the present device.

  8. A Wearable Hydration Sensor with Conformal Nanowire Electrodes.

    PubMed

    Yao, Shanshan; Myers, Amanda; Malhotra, Abhishek; Lin, Feiyan; Bozkurt, Alper; Muth, John F; Zhu, Yong

    2017-03-01

    A wearable skin hydration sensor in the form of a capacitor is demonstrated based on skin impedance measurement. The capacitor consists of two interdigitated or parallel electrodes that are made of silver nanowires (AgNWs) in a polydimethylsiloxane (PDMS) matrix. The flexible and stretchable nature of the AgNW/PDMS electrode allows conformal contact to the skin. The hydration sensor is insensitive to the external humidity change and is calibrated against a commercial skin hydration system on an artificial skin over a wide hydration range. The hydration sensor is packaged into a flexible wristband, together with a network analyzer chip, a button cell battery, and an ultralow power microprocessor with Bluetooth. In addition, a chest patch consisting of a strain sensor, three electrocardiography electrodes, and a skin hydration sensor is developed for multimodal sensing. The wearable wristband and chest patch may be used for low-cost, wireless, and continuous monitoring of skin hydration and other health parameters. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. A cloud computing based 12-lead ECG telemedicine service

    PubMed Central

    2012-01-01

    Background Due to the great variability of 12-lead ECG instruments and medical specialists’ interpretation skills, it remains a challenge to deliver rapid and accurate 12-lead ECG reports with senior cardiologists’ decision making support in emergency telecardiology. Methods We create a new cloud and pervasive computing based 12-lead Electrocardiography (ECG) service to realize ubiquitous 12-lead ECG tele-diagnosis. Results This developed service enables ECG to be transmitted and interpreted via mobile phones. That is, tele-consultation can take place while the patient is on the ambulance, between the onsite clinicians and the off-site senior cardiologists, or among hospitals. Most importantly, this developed service is convenient, efficient, and inexpensive. Conclusions This cloud computing based ECG tele-consultation service expands the traditional 12-lead ECG applications onto the collaboration of clinicians at different locations or among hospitals. In short, this service can greatly improve medical service quality and efficiency, especially for patients in rural areas. This service has been evaluated and proved to be useful by cardiologists in Taiwan. PMID:22838382

  10. Empirical mode decomposition of the ECG signal for noise removal

    NASA Astrophysics Data System (ADS)

    Khan, Jesmin; Bhuiyan, Sharif; Murphy, Gregory; Alam, Mohammad

    2011-04-01

    Electrocardiography is a diagnostic procedure for the detection and diagnosis of heart abnormalities. The electrocardiogram (ECG) signal contains important information that is utilized by physicians for the diagnosis and analysis of heart diseases. So good quality ECG signal plays a vital role for the interpretation and identification of pathological, anatomical and physiological aspects of the whole cardiac muscle. However, the ECG signals are corrupted by noise which severely limit the utility of the recorded ECG signal for medical evaluation. The most common noise presents in the ECG signal is the high frequency noise caused by the forces acting on the electrodes. In this paper, we propose a new ECG denoising method based on the empirical mode decomposition (EMD). The proposed method is able to enhance the ECG signal upon removing the noise with minimum signal distortion. Simulation is done on the MIT-BIH database to verify the efficacy of the proposed algorithm. Experiments show that the presented method offers very good results to remove noise from the ECG signal.

  11. Clinical characterization of cardiovascular abnormalities associated with feline mucopolysaccharidosis I and VI

    PubMed Central

    Sleeper, Meg M.; Kusiak, Catherine M.; Shofer, Frances S.; O’Donnell, Patricia; Bryan, Caroline; Ponder, Katherine P.; Haskins, Mark E.

    2009-01-01

    Summary Objective The purpose of this study was to define the cardiovascular abnormalities present in young and adult cats affected with the lysosomal storage diseases mucopolysaccharidosis (MPS) I and MPS VI. Method Eighteen cats affected with MPS I and fifteen cats affected with MPS VI were evaluated by physical examination, electrocardiography and echocardiography. Electrocardiograms were performed on all MPS I and all but 7 of the MPS VI cats. Ten unaffected cats underwent complete examinations for comparison purposes. Results No cardiovascular physical examination abnormalities were noted. ECG intervals were normal in affected cats; however, changes consistent with aberrant conduction were noted more frequently than in unaffected cats. Significant echocardiographic abnormalities included valve thickening and regurgitation (aortic and mitral) and aortic root dilation, particularly in the older cats. Conclusion As affected animals increased in age, more cardiac abnormalities were found with increasing severity. MPS I and MPS VI cats have similar cardiovascular findings to those seen in children and MPS VII dogs. PMID:18509743

  12. Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

    PubMed Central

    Mochizuki, Yohei; Yoshimatsu, Hiroki; Niina, Ayaka; Teshima, Takahiro; Matsumoto, Hirotaka; Koyama, Hidekazu

    2018-01-01

    Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI). The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed abnormalities in myocardial deformations, including decreased early-to-late diastolic strain rate ratios in longitudinal, radial and circumferential directions, and deteriorated segmental systolic longitudinal strain. At the follow-up examinations, the cat exhibited echocardiographic left ventricular hypertrophy and was diagnosed with hypertrophic cardiomyopathy using conventional echocardiography. Relevance and novel information This is the first report on the use of two-dimensional speckle tracking echocardiography for the early detection of myocardial dysfunction in a cat with hypertrophic cardiomyopathy; the myocardial dysfunction was detected before the development of hypertrophy. The findings from this case suggest that two-dimensional speckle tracking echocardiography can be useful for myocardial assessment when conventional echocardiographic and Doppler findings are ambiguous. PMID:29449957

  13. Pulmonary and heart diseases with inhalation of atmospheric pressure plasma flow

    NASA Astrophysics Data System (ADS)

    Hirata, Takamichi; Murata, Shigeru; Kishimoto, Takumi; Tsutsui, Chihiro; Kondo, Akane; Mori, Akira

    2012-10-01

    We examined blood pressure in the abdominal aorta of mini pig under plasma inhalation of atmospheric pressure plasma flow. The coaxial atmospheric pressure plasma source has a tungsten wire inside a glass capillary, that is surrounded by a grounded tubular electrode. Plasma was generated under the following conditions; applied voltage: 8 kVpp, frequency: 3 kHz, and helium (He) gas flow rate: 1 L/min. On the other hand, sphygmomanometry of a blood vessel proceeded using a device comprising a disposable force transducer, and a bedside monitor for simultaneous electrocardiography and signal pressure measurements. We directly measured Nitric oxide (NO) using a catheter-type NO sensor placed in the coronary sinus through an angiography catheter from the abdomen. Blood pressure decreased from 110/65 to 90/40 mm Hg in the animals in vivo under plasma inhalation. The NO concentration in the abdominal aorta like the blood pressure, reached a maximum value at about 40 s and then gradually decreased.

  14. The Preparticipation Sports Evaluation.

    PubMed

    Mirabelli, Mark H; Devine, Mathew J; Singh, Jaskaran; Mendoza, Michael

    2015-09-01

    The preparticipation physical evaluation is a commonly requested medical visit for amateur and professional athletes of all ages. The overarching goal is to maximize the health of athletes and their safe participation in sports. Although studies have not found that the preparticipation physical evaluation prevents morbidity and mortality associated with sports, it may detect conditions that predispose the athlete to injury or illness and can provide strategies to prevent injuries. Clearance depends on the outcome of the evaluation and the type of sport (and sometimes position or event) in which the athlete participates. All persons undergoing a preparticipation physical evaluation should be questioned about exertional symptoms, presence of a heart murmur, symptoms of Marfan syndrome, and family history of premature serious cardiac conditions or sudden death. The physical examination should focus on the cardiovascular and musculoskeletal systems. U.S. medical and athletic organizations discourage screening electrocardiography and blood and urine testing in asymptomatic patients. Further evaluation should be considered for persons with heart or lung disease, bleeding disorders, musculoskeletal problems, history of concussion, or other neurologic disorders.

  15. Smartphone home monitoring of ECG

    NASA Astrophysics Data System (ADS)

    Szu, Harold; Hsu, Charles; Moon, Gyu; Landa, Joseph; Nakajima, Hiroshi; Hata, Yutaka

    2012-06-01

    A system of ambulatory, halter, electrocardiography (ECG) monitoring system has already been commercially available for recording and transmitting heartbeats data by the Internet. However, it enjoys the confidence with a reservation and thus a limited market penetration, our system was targeting at aging global villagers having an increasingly biomedical wellness (BMW) homecare needs, not hospital related BMI (biomedical illness). It was designed within SWaP-C (Size, Weight, and Power, Cost) using 3 innovative modules: (i) Smart Electrode (lowpower mixed signal embedded with modern compressive sensing and nanotechnology to improve the electrodes' contact impedance); (ii) Learnable Database (in terms of adaptive wavelets transform QRST feature extraction, Sequential Query Relational database allowing home care monitoring retrievable Aided Target Recognition); (iii) Smartphone (touch screen interface, powerful computation capability, caretaker reporting with GPI, ID, and patient panic button for programmable emergence procedure). It can provide a supplementary home screening system for the post or the pre-diagnosis care at home with a build-in database searchable with the time, the place, and the degree of urgency happened, using in-situ screening.

  16. A 36-Year-Old Woman with Coronary Artery Dissection Two Weeks after Abortion.

    PubMed

    Salari, Arsalan; Gholipur, Mahboobe; Rezaeidanesh, Maedeh; Barzigar, Anoosh; Rahmani, Shahram; Pursadeghi, Mohadeseh; Ebrahimi, Hannan

    2016-04-13

    Spontaneous coronary artery dissection is a rare cause of acute coronary syndrome and sudden cardiac death. We report coronary artery dissection in a 36-year-old woman with retrosternal chest pain 2 weeks after abortion. Electrocardiography showed ST elevation in leads V2-V4 and ST depression in the inferior leads. Lab data were normal. Cardiac catheterization showed a suspicious thrombotic lesion at the proximal portion of the left anterior descending artery with a smooth contour consistent with distal haziness and dissection site. Final diagnosis was coronary artery dissection. At 1 week's follow-up, the patient was in good physical condition. At 1 month's follow-up, she had no complaints of discomfort. And finally, 8 months after having suffered a heart attack, she presented no evidence of angina, dyspnea, or congestive heart failure Spontaneous coronary artery dissection is a rare disease that mainly affects younger women. Compared with earlier reports, the prognosis seems to be improved by early diagnosis and interventional treatment.

  17. Fabrication of Flexible Microneedle Array Electrodes for Wearable Bio-Signal Recording.

    PubMed

    Ren, Lei; Xu, Shujia; Gao, Jie; Lin, Zi; Chen, Zhipeng; Liu, Bin; Liang, Liang; Jiang, Lelun

    2018-04-13

    Laser-direct writing (LDW) and magneto-rheological drawing lithography (MRDL) have been proposed for the fabrication of a flexible microneedle array electrode (MAE) for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET) substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE), the electrode-skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG), electroencephalography (EEG) and static electrocardiography (ECG) signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring.

  18. Developing Barbed Microtip-Based Electrode Arrays for Biopotential Measurement

    PubMed Central

    Hsu, Li-Sheng; Tung, Shu-Wei; Kuo, Che-Hsi; Yang, Yao-Joe

    2014-01-01

    This study involved fabricating barbed microtip-based electrode arrays by using silicon wet etching. KOH anisotropic wet etching was employed to form a standard pyramidal microtip array and HF/HNO3 isotropic etching was used to fabricate barbs on these microtips. To improve the electrical conductance between the tip array on the front side of the wafer and the electrical contact on the back side, a through-silicon via was created during the wet etching process. The experimental results show that the forces required to detach the barbed microtip arrays from human skin, a polydimethylsiloxane (PDMS) polymer, and a polyvinylchloride (PVC) film were larger compared with those required to detach microtip arrays that lacked barbs. The impedances of the skin-electrode interface were measured and the performance levels of the proposed dry electrode were characterized. Electrode prototypes that employed the proposed tip arrays were implemented. Electroencephalogram (EEG) and electrocardiography (ECG) recordings using these electrode prototypes were also demonstrated. PMID:25014098

  19. A computer program for processing impedance cardiographic data: Improving accuracy through user-interactive software

    NASA Technical Reports Server (NTRS)

    Cowings, Patricia S.; Naifeh, Karen; Thrasher, Chet

    1988-01-01

    This report contains the source code and documentation for a computer program used to process impedance cardiography data. The cardiodynamic measures derived from impedance cardiography are ventricular stroke column, cardiac output, cardiac index and Heather index. The program digitizes data collected from the Minnesota Impedance Cardiograph, Electrocardiography (ECG), and respiratory cycles and then stores these data on hard disk. It computes the cardiodynamic functions using interactive graphics and stores the means and standard deviations of each 15-sec data epoch on floppy disk. This software was designed on a Digital PRO380 microcomputer and used version 2.0 of P/OS, with (minimally) a 4-channel 16-bit analog/digital (A/D) converter. Applications software is written in FORTRAN 77, and uses Digital's Pro-Tool Kit Real Time Interface Library, CORE Graphic Library, and laboratory routines. Source code can be readily modified to accommodate alternative detection, A/D conversion and interactive graphics. The object code utilizing overlays and multitasking has a maximum of 50 Kbytes.

  20. Recurrence Plots: a New Tool for Quantification of Cardiac Autonomic Nervous System Recovery after Transplant.

    PubMed

    Takakura, Isabela Thomaz; Hoshi, Rosangela Akemi; Santos, Márcio Antonio; Pivatelli, Flávio Correa; Nóbrega, João Honorato; Guedes, Débora Linhares; Nogueira, Victor Freire; Frota, Tuane Queiroz; Castelo, Gabriel Castro; Godoy, Moacir Fernandes de

    2017-01-01

    To evaluate a possible evolutionary post-heart transplant return of autonomic function using quantitative and qualitative information from recurrence plots. Using electrocardiography, 102 RR tachograms of 45 patients (64.4% male) who underwent heart transplantation and that were available in the database were analyzed at different follow-up periods. The RR tachograms were collected from patients in the supine position for about 20 minutes. A time series with 1000 RR intervals was analyzed, a recurrence plot was created, and the following quantitative variables were evaluated: percentage of determinism, percentage of recurrence, average diagonal length, Shannon entropy, and sample entropy, as well as the visual qualitative aspect. Quantitative and qualitative signs of heart rate variability recovery were observed after transplantation. There is evidence that autonomic innervation of the heart begins to happen gradually after transplantation. Quantitative and qualitative analyses of recurrence can be useful tools for monitoring cardiac transplant patients and detecting the gradual return of heart rate variability.

  1. Audit of availability and distribution of paediatric cardiology services and facilities in Nigeria

    PubMed Central

    Ekure, Ekanem N; Sadoh, Wilson E; Bode-Thomas, Fidelia; Yilgwan, Christopher S; Orogade, Adeola A; Animasahun, Adeola B; Ogunkunle, Oluwatoyin O; Omokhodion, Samuel I; Babaniyi, Iretiola; Anah, Maxwell U; Otaigbe, Barbara E; Olowu, Adebiyi; Okpokowuruk, Frances; Maduka, Ogechi C; Onakpoya, Uvie U; Adiele, Daberechi K; Sani, Usman. M; Asani, Mustapha; Daniels, Queennette; Uzodimma, Chinyere C; Duru, Chika O; Abdulkadir, Mohammad B; Afolabi, Joseph K; Okeniyi, John A

    2017-01-01

    Summary Background Paediatric cardiac services in Nigeria have been perceived to be inadequate but no formal documentation of availability and distribution of facilities and services has been done. Objective: To evaluate and document the currently available paediatric cardiac services in Nigeria. Methods In this questionnaire-based, cross-sectional descriptive study, an audit was undertaken from January 2010 to December 2014, of the personnel and infrastructure, with their distributions according to geopolitical zones of Nigeria. Results Forty-eight centres participated in the study, with 33 paediatric cardiologists and 31 cardiac surgeons. Echocardiography, electrocardiography and pulse oximetry were available in 45 (93.8%) centres while paediatric intensive care units were in 23 (47.9%). Open-heart surgery was performed in six (12.5%) centres. South-West zone had the majority of centres (20; 41.7%). Conclusions Available paediatric cardiac services in Nigeria are grossly inadequate and poorly distributed. Efforts should be intensified to upgrade existing facilities, establish new and functional centres, and train personnel. PMID:27701490

  2. Audit of availability and distribution of paediatric cardiology services and facilities in Nigeria.

    PubMed

    Ekure, Ekanem N; Sadoh, Wilson E; Bode-Thomas, Fidelia; Orogade, Adeola A; Animasahun, Adeola B; Ogunkunle, Oluwatoyin O; Babaniyi, Iretiola; Anah, Maxwell U; Otaigbe, Barbara E; Olowu, Adebiyi; Okpokowuruk, Frances; Omokhodion, Samuel I; Maduka, Ogechi C; Onakpoya, Uvie U; Adiele, Daberechi K; Sani, Usman M; Asani, Mustapha; Yilgwan, Christopher S; Daniels, Queennette; Uzodimma, Chinyere C; Duru, Chika O; Abdulkadir, Mohammad B; Afolabi, Joseph K; Okeniyi, John A

    Paediatric cardiac services in Nigeria have been perceived to be inadequate but no formal documentation of availability and distribution of facilities and services has been done. To evaluate and document the currently available paediatric cardiac services in Nigeria. In this questionnaire-based, cross-sectional descriptive study, an audit was undertaken from January 2010 to December 2014, of the personnel and infrastructure, with their distributions according to geopolitical zones of Nigeria. Forty-eight centres participated in the study, with 33 paediatric cardiologists and 31 cardiac surgeons. Echocardiography, electrocardiography and pulse oximetry were available in 45 (93.8%) centres while paediatric intensive care units were in 23 (47.9%). Open-heart surgery was performed in six (12.5%) centres. South-West zone had the majority of centres (20; 41.7%). Available paediatric cardiac services in Nigeria are grossly inadequate and poorly distributed. Efforts should be intensified to upgrade existing facilities, establish new and functional centres, and train personnel.

  3. The value of electrocardiography for differential diagnosis in wide QRS complex tachycardia.

    PubMed

    Sousa, Pedro A; Pereira, Salomé; Candeias, Rui; de Jesus, Ilídio

    2014-03-01

    Correct diagnosis in wide QRS complex tachycardia remains a challenge. Differential diagnosis between ventricular and supraventricular tachycardia has important therapeutic and prognostic implications, and although data from clinical history and physical examination may suggest a particular origin, it is the 12-lead surface electrocardiogram that usually enables this differentiation. Since 1978, various electrocardiographic criteria have been proposed for the differential diagnosis of wide complex tachycardias, particularly the presence of atrioventricular dissociation, and the axis, duration and morphology of QRS complexes. Despite the wide variety of criteria, diagnosis is still often difficult, and errors can have serious consequences. To reduce such errors, several differential diagnosis algorithms have been proposed since 1991. However, in a small percentage of wide QRS tachycardias the diagnosis remains uncertain and in these the wisest decision is to treat them as ventricular tachycardias. The authors' objective was to review the main electrocardiographic criteria and differential diagnosis algorithms of wide QRS tachycardia. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  4. Spontaneous coronary artery dissection as a cause of myocardial infarction

    PubMed Central

    Aksakal, Aytekin; Arslan, Uğur; Yaman, Mehmet; Urumdaş, Mehmet; Ateş, Ahmet Hakan

    2014-01-01

    Spontaneous coronary artery dissection (SCAD) is a rare disease that is usually seen in young women in left descending coronary artery and result in events like sudden cardiac death and acute myocardial infarction. A 70-year-old man was admitted to the emergency department with chest pain which started 1 h ago during a relative’s funeral. The initial electrocardiography demonstrated 2 mm ST-segment depression in leads V1-V3 and the patient underwent emergent coronary angiography. SCAD simultaneously in two different coronary arteries [left anterior descending (LAD) artery and left circumflex (LCx)] artery was detected and SCAD in LCx artery was causing total occlusion which resulted in acute myocardial infarction. Successful stenting was performed thereafter for both lesions. In addition to the existence of SCAD simultaneously in two different coronary arteries, the presence of muscular bridge and SCAD together at the same site of the LAD artery was another interesting point which made us report this case. PMID:25548620

  5. A cloud computing based 12-lead ECG telemedicine service.

    PubMed

    Hsieh, Jui-Chien; Hsu, Meng-Wei

    2012-07-28

    Due to the great variability of 12-lead ECG instruments and medical specialists' interpretation skills, it remains a challenge to deliver rapid and accurate 12-lead ECG reports with senior cardiologists' decision making support in emergency telecardiology. We create a new cloud and pervasive computing based 12-lead Electrocardiography (ECG) service to realize ubiquitous 12-lead ECG tele-diagnosis. This developed service enables ECG to be transmitted and interpreted via mobile phones. That is, tele-consultation can take place while the patient is on the ambulance, between the onsite clinicians and the off-site senior cardiologists, or among hospitals. Most importantly, this developed service is convenient, efficient, and inexpensive. This cloud computing based ECG tele-consultation service expands the traditional 12-lead ECG applications onto the collaboration of clinicians at different locations or among hospitals. In short, this service can greatly improve medical service quality and efficiency, especially for patients in rural areas. This service has been evaluated and proved to be useful by cardiologists in Taiwan.

  6. Fabrication of Flexible Microneedle Array Electrodes for Wearable Bio-Signal Recording

    PubMed Central

    Ren, Lei; Xu, Shujia; Gao, Jie; Lin, Zi; Chen, Zhipeng; Liu, Bin; Liang, Liang; Jiang, Lelun

    2018-01-01

    Laser-direct writing (LDW) and magneto-rheological drawing lithography (MRDL) have been proposed for the fabrication of a flexible microneedle array electrode (MAE) for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET) substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE), the electrode–skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG), electroencephalography (EEG) and static electrocardiography (ECG) signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring. PMID:29652835

  7. Inducing Sadness and Anxiousness through Visual Media: Measurement Techniques and Persistence

    PubMed Central

    Kuijsters, Andre; Redi, Judith; de Ruyter, Boris; Heynderickx, Ingrid

    2016-01-01

    The persistence of negative moods (sadness and anxiousness) induced by three visual Mood Induction Procedures (MIP) was investigated. The evolution of the mood after the MIP was monitored for a period of 8 min with the Self-Assessment Manikin (SAM; every 2 min) and with recordings of skin conductance level (SCL) and electrocardiography (ECG). The SAM pleasure ratings showed that short and longer film fragments were effective in inducing a longer lasting negative mood, whereas the negative mood induced by the IAPS slideshow was short lived. The induced arousal during the anxious MIPs diminished quickly after the mood induction; nevertheless, the SCL data suggest longer lasting arousal effects for both movies. The decay of the induced mood follows a logarithmic function; diminishing quickly in the first minutes, thereafter returning slowly back to baseline. These results reveal that caution is needed when investigating the effects of the induced mood on a task or the effect of interventions on induced moods, because the induced mood diminishes quickly after the mood induction. PMID:27536260

  8. Comparison of infant heart rate assessment by auscultation, ECG and oximetry in the delivery room.

    PubMed

    Murphy, Madeleine C; De Angelis, Laura; McCarthy, Lisa K; O'Donnell, Colm Patrick Finbarr

    2018-05-25

    Clinical assessment of an infant's heart rate (HR) in the delivery room (DR) has been reported to be inaccurate. We compared auscultation of the HR using a stethoscope with electrocardiography (ECG) and pulse oximetry (PO) for determining the HR in 92 low-risk newborn infants in the DR. Caregivers auscultated the HR while masked to the HR on the monitor. Auscultation underestimated ECG HR (mean difference (95% CI) by -9 (-15 to -2) beats per minute (bpm)) and PO HR (mean difference (95% CI) by -5 (-12 to 2) bpm). The median (IQR) time to HR by auscultation was 14 (10-18) s. As HR was determined quickly and with reasonable accuracy by auscultation in low-risk newborns, study in high-risk infants is warranted. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Music therapy with disorders of consciousness: current evidence and emergent evidence-based practice.

    PubMed

    Magee, Wendy L; O'Kelly, Julian

    2015-03-01

    Patients with prolonged disorders of consciousness (PDOC) stemming from acquired brain injury present one of the most challenging clinical populations in neurological rehabilitation. Because of the complex clinical presentation of PDOC patients, treatment teams are confronted with many medicolegal, ethical, philosophical, moral, and religious issues in day-to-day care. Accurate diagnosis is of central concern, relying on creative approaches from skilled clinical professionals using combined behavioral and neurophysiological measures. This paper presents the latest evidence for using music as a diagnostic tool with PDOC, including recent developments in music therapy interventions and measurement. We outline standardized clinical protocols and behavioral measures to produce diagnostic outcomes and examine recent research illustrating a range of benefits of music-based methods at behavioral, cardiorespiratory, and cortical levels using video, electrocardiography, and electroencephalography methods. These latest developments are discussed in the context of evidence-based practice in rehabilitation with clinical populations. © 2014 New York Academy of Sciences.

  10. smRithm: Graphical user interface for heart rate variability analysis.

    PubMed

    Nara, Sanjeev; Kaur, Manvinder; Datta, Saurav

    2015-01-01

    Over the past 25 years, Heart rate variability (HRV) has become a non-invasive research and clinical tool for indirectly carrying out investigation of both cardiac and autonomic system function in both healthy and diseased. It provides valuable information about a wide range of cardiovascular disorders, pulmonary diseases, neurological diseases, etc. Its primary purpose is to access the functioning of the nervous system. The source of information for HRV analysis is the continuous beat to beat measurement of inter-beat intervals. The electrocardiography (ECG or EKG) is considered as the best way to measure inter-beat intervals. This paper proposes an open source Graphical User Interface (GUI): smRithm developed in MATLAB for HRV analysis that will apply effective techniques on the raw ECG signals to process and decompose it in a simpler manner to obtain more useful information out of signals that can be utilized for more powerful and efficient applications in the near future related to HRV.

  11. QRS slopes for assessment of myocardial damage in chronic chagasic patients

    NASA Astrophysics Data System (ADS)

    Pueyo, E.; Laciar, E.; Anzuola, E.; Laguna, P.; Jané, R.

    2007-11-01

    In this study the slopes of the QRS complex are evaluated for determination of the degree of myocardial damage in chronic chagasic patients. Previous studies have demonstrated the ability of the slope indices to reflect alterations in the conduction velocity of the cardiac impulse. Results obtained in the present study show that chronic chagasic patients have significantly flatter QRS slopes as compared to healthy subjects. Not only that but the extent of slope lessening turns out to be proportional to the degree of myocardial damage caused by the disease. Additionally, when incorporating the slope indices into a classification analysis together with other indices indicative of the presence of ventricular late potentials obtained from high resolution electrocardiography, results show that the percentages of correct classification increase up to 62.5%, which means eight points above the percentages obtained prior to incorporation of the slope indices. It can be concluded that QRS slopes have great potential for assessing the degree of severity associated with Chagas' disease.

  12. Impact of human emotions on physiological characteristics

    NASA Astrophysics Data System (ADS)

    Partila, P.; Voznak, M.; Peterek, T.; Penhaker, M.; Novak, V.; Tovarek, J.; Mehic, Miralem; Vojtech, L.

    2014-05-01

    Emotional states of humans and their impact on physiological and neurological characteristics are discussed in this paper. This problem is the goal of many teams who have dealt with this topic. Nowadays, it is necessary to increase the accuracy of methods for obtaining information about correlations between emotional state and physiological changes. To be able to record these changes, we focused on two majority emotional states. Studied subjects were psychologically stimulated to neutral - calm and then to the stress state. Electrocardiography, Electroencephalography and blood pressure represented neurological and physiological samples that were collected during patient's stimulated conditions. Speech activity was recording during the patient was reading selected text. Feature extraction was calculated by speech processing operations. Classifier based on Gaussian Mixture Model was trained and tested using Mel-Frequency Cepstral Coefficients extracted from the patient's speech. All measurements were performed in a chamber with electromagnetic compatibility. The article discusses a method for determining the influence of stress emotional state on the human and his physiological and neurological changes.

  13. Interpretation of symptoms as a cause of delays in patients with acute myocardial infarction, Istanbul, Turkey.

    PubMed

    Koc, Sema; Durna, Zehra; Akin, Semiha

    2017-06-14

    This cross-sectional study aimed to assess interpretation of symptoms as a cause of delays in patients with acute myocardial infarction (AMI). It was conducted at a university hospital in Istanbul, Turkey. The sample included 93 patients: 73 male, mean age 57.89 (12.13) years. Prehospital delay time ranged from 15 minutes to 10 days, with a median of 2 hours (interquartile range: 9.50). Patients waited for pain to go away (48.4%) and tried to calm down (39.8%). Most patients attributed AMI-related symptoms to a reason other than heart disease. In a multivariate logistic regression analysis, the type of AMI was classified based on electrocardiography findings (odds ratio 5.18, 95% confidence interval: 1.69-15.91, P=0.004) and was independently associated with a long prehospital delay time, indicating that patients with ST segment elevation MI would seek early medical care. Misinterpretation of symptoms and misconceptions about emergency treatment during AMI cause delays in admission and may affect treatment.

  14. Challenges of ECG monitoring and ECG interpretation in dialysis units.

    PubMed

    Poulikakos, Dimitrios; Malik, Marek

    Patients on hemodialysis (HD) suffer from high cardiovascular morbidity and mortality due to high rates of coronary artery disease and arrhythmias. Electrocardiography (ECG) is often performed in the dialysis units as part of routine clinical assessment. However, fluid and electrolyte changes have been shown to affect all ECG morphologies and intervals. ECG interpretation thus depends on the time of the recording in relation to the HD session. In addition, arrhythmias during HD are common, and dialysis-related ECG artifacts mimicking arrhythmias have been reported. Studies using advanced ECG analyses have examined the impact of the HD procedure on selected repolarization descriptors and heart rate variability indices. Despite the challenges related to the impact of the fluctuant fluid and electrolyte status on conventional and advanced ECG parameters, further research in ECG monitoring during dialysis has the potential to provide clinically meaningful and practically useful information for diagnostic and risk stratification purposes. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  15. Computer-aided detection of acute pulmonary embolism with 64-slice multi-detector row computed tomography: impact of the scanning conditions and overall image quality in the detection of peripheral clots.

    PubMed

    Dewailly, Marion; Rémy-Jardin, Martine; Duhamel, Alain; Faivre, Jean-Baptiste; Pontana, François; Deken, Valérie; Bakai, Anne-Marie; Remy, Jacques

    2010-01-01

    To evaluate the performance of a computer-aided detection (CAD) system for diagnosing peripheral acute pulmonary embolism (PE) with a 64-slice multi-detector row computed tomography (CT). Two radiologists investigated the accuracy of a software aimed at detecting peripheral clots (PECAD prototype, version 7; Siemens Medical Systems, Forchheim, Germany) by applying this tool for the analysis of the pulmonary arterial bed of 74 CT angiograms obtained with 64-slice dual-source CT (Definition; Siemens Medical Systems). These cases were retrospectively selected from a database of CT studies performed on the same CT unit, with a similar collimation (64 x 0.6 mm) and similar injection protocols. Patient selection was based on a variety of (1) scanning conditions, namely, nongated (n = 30), electrocardiography-gated (n = 30), and dual-energy CT angiograms (n = 14), and (2) image quality (IQ), namely, scans of excellent IQ (n = 53) and lower IQ due to lower levels of arterial enhancement and/or presence of noise (n = 21). The standard of truth was based on the 2 radiologists' consensus reading and the results of CAD. The software detected 80 of 93 peripheral clots present in the 21 patients (42 segmental and 38 subsegmental clots). The overall sensitivity (95% confidence interval) of the CAD tool was 86% (77%-92%) for detecting peripheral clots, 78% (64.5%-88%) at the segmental level and 97% (85.5%-99.9%) at the subsegmental level. Assuming normal vascular anatomy with 20 segmental and 40 subsegmental arteries, overall specificity and positive and negative predictive values (95% confidence interval) of the software were 91.8% (91%-92.6%), 18.4% (15%-22.4%), and 99.7% (99.5%-99.8%), respectively. A mean of 5.4 false positives was found per patient (total, 354 false positives), mainly linked to the presence of perivascular connective tissue (n = 119; 34%) and perivascular airspace consolidation (n = 97; 27%). The sensitivities (95% confidence interval) for the CAD tool were 91% (69.8%-99.3%) for dual-energy, 87% (59.3%-93.2%) for electrocardiography-gated, and 87% (73.5%-95.3%) for nongated scans (P > 0.05). No significant difference was found in the sensitivity of the CAD software when comparing the scans according to the scanning conditions and image quality. The evaluated CAD software has a good sensitivity in detecting peripheral PE, which is not influenced by the scanning conditions or the overall image quality.

  16. Gender-related differences in clinical presentation, electrocardiography signs, laboratory markers and outcome in patients with acute pulmonary embolism.

    PubMed

    Obradović, Slobodan; Džudović, Boris; Rusović, Siniša; Subota, Vesna; Obradović, Dragana

    2016-09-01

    Acute pulmonary embolism (PE) is a potentially life threating event, but there are scarce data about genderrelated differences in this condition. The aim of this study was to identify gender-specific differences in clinical presentation, the diagnosis and outcome between male and female patients with PE. We analysed the data of 144 consecutive patients with PE (50% women) and compared female and male patients regarding clinical presentation, electrocardiography (ECG) signs, basic laboratory markers and six-month outcome. All the patients confirmed PE by visualized thrombus on the multidetector computed tomography with pulmonary angiography (MDCTPA), ECG and echocardiographic examination at admission. Compared to the men, the women were older and a larger proportion of them was in the third tertile of age (66.0% vs 34.0%, p = 0.008). In univariate analysis the men more often had hemoptysis [OR (95% CI) 3.75 (1.16-12.11)], chest pain [OR (95% CI) 3.31 (1.57-7.00)] febrile state [OR (95% CI) 2.41 (1.12-5.22)] and pneumonia at PE presentation [OR (95% CI) 3.40 (1.25-9.22)] and less likely had heart decompensation early in the course of the disease [OR (95%CI) 0.48 (0.24-0.97)]. In the multivariate analysis a significant difference in the rate of pneumonia and acute heart failure between genders disappeared due to strong influence of age. There was no significant difference in the occurrence of typical ECG signs for PE between the genders. Women had higher level of admission glycaemia [7.7 mmol/L (5.5-8.2 mmol/L) vs 6.9 mmol/L (6.3-9.6 mmol/L), p = 0.006] and total number of leukocytes [10.5 x 109/L (8.8-12.7 x 109/L vs 8.7 x 109/L (7.0-11.6 x 109/L)), p = 0.007]. There was a trend toward higher plasma level of brain natriuretic peptide in women compared to men 127.1 pg/mL (55.0-484.0 pg/mL), p = 0.092] vs [90.3 pg/mL (39.2-308.5 pg/mL). The main 6-month outcomes, death and major bleeding, had similar frequencies in both sexes. There are several important differences between men and women in the clinical presentation of PE and basic laboratory findings which can influence the diagnosis and treatment of PE.

  17. Diagnosis and treatment of fetal cardiac disease: a scientific statement from the American Heart Association.

    PubMed

    Donofrio, Mary T; Moon-Grady, Anita J; Hornberger, Lisa K; Copel, Joshua A; Sklansky, Mark S; Abuhamad, Alfred; Cuneo, Bettina F; Huhta, James C; Jonas, Richard A; Krishnan, Anita; Lacey, Stephanie; Lee, Wesley; Michelfelder, Erik C; Rempel, Gwen R; Silverman, Norman H; Spray, Thomas L; Strasburger, Janette F; Tworetzky, Wayne; Rychik, Jack

    2014-05-27

    The goal of this statement is to review available literature and to put forth a scientific statement on the current practice of fetal cardiac medicine, including the diagnosis and management of fetal cardiovascular disease. A writing group appointed by the American Heart Association reviewed the available literature pertaining to topics relevant to fetal cardiac medicine, including the diagnosis of congenital heart disease and arrhythmias, assessment of cardiac function and the cardiovascular system, and available treatment options. The American College of Cardiology/American Heart Association classification of recommendations and level of evidence for practice guidelines were applied to the current practice of fetal cardiac medicine. Recommendations relating to the specifics of fetal diagnosis, including the timing of referral for study, indications for referral, and experience suggested for performance and interpretation of studies, are presented. The components of a fetal echocardiogram are described in detail, including descriptions of the assessment of cardiac anatomy, cardiac function, and rhythm. Complementary modalities for fetal cardiac assessment are reviewed, including the use of advanced ultrasound techniques, fetal magnetic resonance imaging, and fetal magnetocardiography and electrocardiography for rhythm assessment. Models for parental counseling and a discussion of parental stress and depression assessments are reviewed. Available fetal therapies, including medical management for arrhythmias or heart failure and closed or open intervention for diseases affecting the cardiovascular system such as twin-twin transfusion syndrome, lung masses, and vascular tumors, are highlighted. Catheter-based intervention strategies to prevent the progression of disease in utero are also discussed. Recommendations for delivery planning strategies for fetuses with congenital heart disease including models based on classification of disease severity and delivery room treatment will be highlighted. Outcome assessment is reviewed to show the benefit of prenatal diagnosis and management as they affect outcome for babies with congenital heart disease. Fetal cardiac medicine has evolved considerably over the past 2 decades, predominantly in response to advances in imaging technology and innovations in therapies. The diagnosis of cardiac disease in the fetus is mostly made with ultrasound; however, new technologies, including 3- and 4-dimensional echocardiography, magnetic resonance imaging, and fetal electrocardiography and magnetocardiography, are available. Medical and interventional treatments for select diseases and strategies for delivery room care enable stabilization of high-risk fetuses and contribute to improved outcomes. This statement highlights what is currently known and recommended on the basis of evidence and experience in the rapidly advancing and highly specialized field of fetal cardiac care. © 2014 American Heart Association, Inc.

  18. [Functional cardiovascular assessment in dentists performing local anesthesia in out-patient settings].

    PubMed

    Rabinovich, S A; Razumova, S N; Vasil'ev, Yu L

    The article presents the results of the cardiovascular changes assessment using electrocardiography (ECG) monitoring during local anesthesia in GP dentists. Selective ECG monitoring was carried out in 60 dentists aged 25-55 years (1 group - 25-34 y.o.; 2 group - 35-44 y.o.; 3 group - 45-55 y.o.) by means of portable «Valens» system. The study of stress index or the index of regulatory systems tension (IT) was conducted for 6 hours in the first day half within 1 working day. IT from 50 to 150 relative units was considered normal. In the first group IT peak was observed at the time of expectation of clinically relevant anesthesia in upper and lower jaw, while in the second and third groups it was associated with pain reaction in the course of treatment despite of clinical signs of anesthesia in the maxilla (IT=20±5.3 and 231±1.4, correspondingly) and mandible (IT=213±2.7 and 223±2.6, correspondingly). In all groups greater IT correlated more with mandible anesthesia events.

  19. [Cardiovascular diseases in the population of industrial towns and environmental factors].

    PubMed

    Ibraeva, L K; Azhimetova, G N; Amanbekova, A U; Bakirova, R E

    2015-01-01

    To study the influence of environmental factors (EFs) on the development of cardiovascular diseases in the population of industrial towns of the Republic of Kazakhstan. The investigation covered an 18-59-year-old adult population who had been living in the urbanized areas of the Republic of Kazakhstan for at least 10 years, who worked in harmless conditions and were unregistered as having chronic diseases. At Stage 1, screening (a therapist's examination, blood general and immunological tests, and electrocardiography) was carried out for risk group persons who underwent in-depth clinical examination (blood biochemical test) at Stage 2. Multivariate statistical analysis has revealed that the development of hypertension is associated with the high concentration of sulfur dioxide in atmospheric air, copper in dust sediments, and zinc in soil and that of coronary heart disease (CHD) is related to the high levels of nitrogen dioxide in atmospheric air and zinc in dust sediments. Based on pathogenetic and statistical data and information available in the literature, hypertension and CHD are referred to as the diseases that may result from the influence of EFs.

  20. Influence of gestational age and time of day in baseline and heart rate variation of fetuses.

    PubMed

    Li, Guangfei; Zhang, Song; Yang, Lin; Li, Shufang; Wang, Yan; Hao, Dongmei; Yang, Yimin; Li, Xuwen; Zhang, Lei; Xu, Mingzhou

    2016-04-29

    Fetal electrocardiography (FECG) places electrodes on the maternal abdomen to convert the fetal electrocardiosignals into fetal heart rate (FHR), improving the accuracy and comfort of pregnant woman. At the same time, FECG simplifies the procedure of long term monitoring in the perinatal period. Investigating the influence of gestational age and time of day on FHR features to distinguish between non-stress test (NST) normal fetuses and NST suspicious fetuses. A novel method of FHR baseline estimation was presented; then baseline value and fetal heart rate variation (FHRV) were analyzed in the time domain using FHR signals recorded from 52 fetuses. Baseline values in 1:00, 2:00, 4:00, 5:00 and heart rate variation (HRV) distribution showed a significant difference (p< 0.05) between NST normal fetuses and NST suspicious fetuses. The results suggest that NST normal and suspicious fetuses had same outcome and different FHR features. Accurately distinguishing normal fetuses and suspicious fetuses is important for lowering the false positive rate and reducing unnecessary clinical intervention.

  1. A rare case of renal infarction caused by infective endocarditis.

    PubMed

    Zakaria, Rasheed; Forsyth, Vhari; Rosenbaum, Tomas

    2009-10-01

    A 29-year-old man presented to the emergency department of a general hospital complaining of sudden onset left loin pain, radiating to the groin, which had started 48 h previously. He described no urological symptoms and had no medical history of note. Physical examination, electrocardiography, dipstick testing of urine, radiography of the chest and abdomen, blood tests (white blood cell count and serum urea, creatinine, sodium, potassium and C-reactive protein levels), CT of the renal tract, blood and urine cultures, renal angiography, thromboembolic blood panel, urine and blood tests for illicit drugs, transthoracic echocardiography, transesophageal echocardiography, renal ultrasonography. Infective endocarditis resulting in thromboembolic unilateral renal infarction. The patient was started on anticoagulation therapy with low-molecular-weight heparin and treated with intravenous gentamicin and benzylpenicillin for 4 weeks. He was seen in an outpatient clinic 4 weeks after discharge, at which time serum urea and creatinine levels and repeat ultrasonography of the renal tract confirmed normal renal function. He will be followed up regularly by cardiologists and urologists, at 6 weeks initially, and every 6 months to 1 year thereafter by his family physician.

  2. Knowledge-based approaches to the maintenance of a large controlled medical terminology.

    PubMed Central

    Cimino, J J; Clayton, P D; Hripcsak, G; Johnson, S B

    1994-01-01

    OBJECTIVE: Develop a knowledge-based representation for a controlled terminology of clinical information to facilitate creation, maintenance, and use of the terminology. DESIGN: The Medical Entities Dictionary (MED) is a semantic network, based on the Unified Medical Language System (UMLS), with a directed acyclic graph to represent multiple hierarchies. Terms from four hospital systems (laboratory, electrocardiography, medical records coding, and pharmacy) were added as nodes in the network. Additional knowledge about terms, added as semantic links, was used to assist in integration, harmonization, and automated classification of disparate terminologies. RESULTS: The MED contains 32,767 terms and is in active clinical use. Automated classification was successfully applied to terms for laboratory specimens, laboratory tests, and medications. One benefit of the approach has been the automated inclusion of medications into multiple pharmacologic and allergenic classes that were not present in the pharmacy system. Another benefit has been the reduction of maintenance efforts by 90%. CONCLUSION: The MED is a hybrid of terminology and knowledge. It provides domain coverage, synonymy, consistency of views, explicit relationships, and multiple classification while preventing redundancy, ambiguity (homonymy) and misclassification. PMID:7719786

  3. Intraoperative "Kounis syndrome" that improved electrocardiography changes and hemodynamic situation after administering nitroglycerine.

    PubMed

    Sánchez, Victoria O; Roca, Luisa C; Moreno, Angel Del P

    2014-01-01

    A 58-year-old female without cardiovascular risk factors, was going to be operated to repair the rotator cuff. Induction and interscalene brachial plexus block were uneventful, but after her placement for surgery the patient started with severe bronchospasm, hypotension, cutaneous allergic reaction and ST elevation on the electrocardiogram. An anaphylactic shock was suspected and treated but until the perfusion of nitroglycerina was started no electrocardiographic changes resolved. After necessary diagnostic test the final diagnosis was variant I of Kounis syndrome due to cefazolin and rocuronium. Ephinephrine is the cornerstone of treatment for anaphylaxis but should we use it if the anaphylactic reaction is also accompanied by myocardial ischemia? The answer is that we should not use it because myocardial ischemia in this syndrome is caused by vasospasm, so it would be more useful drugs such as nitroglycerin. But what if we do not know if it is a Kounis syndrome or not? In this article we report our experience that maybe could help you in a similar situation. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  4. PROPOSED SIMPLE METHOD FOR ELECTROCARDIOGRAM RECORDING IN FREE-RANGING ASIAN ELEPHANTS (ELEPHAS MAXIMUS).

    PubMed

    Chai, Norin; Pouchelon, Jean Louis; Bouvard, Jonathan; Sillero, Leonor Camacho; Huynh, Minh; Segalini, Vincent; Point, Lisa; Croce, Veronica; Rigaux, Goulven; Highwood, Jack; Chetboul, Valérie

    2016-03-01

    Electrocardiography represents a relevant diagnostic tool for detecting cardiac disease in animals. Elephants can present various congenital and acquired cardiovascular diseases. However, few electrophysiologic studies have been reported in captive elephants, mainly due to challenging technical difficulties in obtaining good-quality electrocardiogram (ECG) tracings, and no data are currently available for free-ranging Asian elephants (Elephas maximus). The purpose of this pilot prospective study was to evaluate the feasibility of using a simple method for recording ECG tracings in wild, apparently healthy, unsedated Asian elephants (n = 7) in the standing position. Successful six-lead recordings (I, II, III, aVR, aVL, and aVF) were obtained, with the aVL lead providing the best-quality tracings in most animals. Variables measured in the aVL lead included heart rate, amplitudes and duration of the P waves, QRS complexes, T and U waves, and duration of the PR, QT, and QU intervals. A negative deflection following positive P waves, representative of an atrial repolarization wave (Ta wave), was observed for five out of the seven elephants.

  5. Electrocardiographic features of sudden unexpected death in epilepsy.

    PubMed

    Chyou, Janice Y; Friedman, Daniel; Cerrone, Marina; Slater, William; Guo, Yu; Taupin, Daniel; O'Rourke, Sean; Priori, Silvia G; Devinsky, Orrin

    2016-07-01

    Sudden unexpected death in epilepsy (SUDEP) is the most common cause of epilepsy-related mortality. We hypothesized that electrocardiography (ECG) features may distinguish SUDEP cases from living subjects with epilepsy. Using a matched case-control design, we compared ECG studies of 12 consecutive cases of SUDEP over 10 years and 22 epilepsy controls matched for age, sex, epilepsy type (focal, generalized, or unknown/mixed type), concomitant antiepileptic, and psychotropic drug classes. Conduction intervals and prevalence of abnormal ventricular conduction diagnosis (QRS ≥110 msec), abnormal ventricular conduction pattern (QRS <110 msec, morphology of incomplete right or left bundle branch block or intraventricular conduction delay), early repolarization, and features of inherited cardiac channelopathies were assessed. Abnormal ventricular conduction diagnosis and pattern distinguished SUDEP cases from matched controls. Abnormal ventricular conduction diagnosis was present in two cases and no controls. Abnormal ventricular conduction pattern was more common in cases than controls (58% vs. 18%, p = 0.04). Early repolarization was similarly prevalent in cases and controls, but the overall prevalence exceeded that of published community-based cohorts. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  6. Increased neutrophil to lymphocyte ratio predicts myocardial injury in patients undergoing non-cardiac surgery.

    PubMed

    Durmuş, Gündüz; Belen, Erdal; Can, Mehmet Mustafa

    The neutrophil to lymphocyte ratio (NLR), has been proposed as potential indicator of cardiovascular events. Our aim was to determine the relationship between NLR and development of myocardial injury after non-cardiac surgery (MINS). This observational cohort study included 255 consecutive noncardiac surgery patients aged ≥45 years. Electrocardiography recordings and high sensitivity cardiac troponin T (hscTnT) levels of the patients were obtained for a period of 3 days postoperatively. MINS was detected in 30 (11.8%) patients using the cut-off level of ≥14 ng/L for hscTnT. In the MINS group NLR (3.79 ± 0.7 vs. 2.69 ± 0.6, p < 0.000) values were higher than non-NLR group. The NLR to be independently associated with the development of MINS (OR: 11.690; CI: 4.619-29.585, p < 0.000). NLR seems to be a simple, easy and cheap tool to predict the development of MINS in patient undergoing non-cardiac surgery. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Assessment of the QT interval in the electroencephalography (EEG) of children with syncope, epilepsy, and attention-deficit hyperactivity disorder (ADHD).

    PubMed

    Jha, Om P; Khurana, Divya S; Carvalho, Karen S; Melvin, Joseph J; Legido, Agustin; O'Riordan, Anna C; Valencia, Ignacio

    2010-03-01

    The interpretation of QT interval is often neglected during electroencephalography (EEG) reading. We compared the incidence of prolonged QT interval, as seen in the electrocardiography (ECG) recording lead of the EEG, in children presenting with seizure, syncope, or attention-deficit hyperactivity disorder (ADHD). Abnormal QT was defined as >460 ms. The incidence of prolonged QT in the seizure, syncope, and ADHD groups was 1/50 (2%), 7/50 (14%), and 2/50 (4%), respectively (P = .036, chi-square). The mean +/- SD of QT were 405 +/- 34, 424 +/- 39, and 414 +/- 36, respectively (P = .035, analysis of variance [ANOVA], syncope group, compared with seizure group). The incidence of prolonged QT as measured in the EEG was unexpectedly high in children presenting with seizure, syncope, or ADHD. These data support the concept that QT evaluation should be emphasized during routine EEG reading, as it may aid in identifying cases of undiagnosed cardiac conduction abnormalities. Prospective studies comparing EEG-ECG tracings with 12-lead ECG are warranted.

  8. Printed soft-electronics for remote body monitoring

    NASA Astrophysics Data System (ADS)

    Mantysalo, Matti; Vuorinen, Tiina; Jeihani, Vala; Vehkaoja, Antti

    2017-08-01

    Wearable electronics has emerged into the consumer markets over the past few years. Wrist worn and textile integrated devices are the most common apparatuses for unobtrusive monitoring in sports and wellness sectors. Disposable patches and bandages, however, represent the new era of wearable electronics. Soft and stretchable electronics is the enabling technology of this paradigm shift. It can conform to temporary transfer tattoo and deform with the skin without detachment or fracture. In this paper, we focus on screen-printed soft-electronics for remote body monitoring. We will present a fabrication process of a skin conformable electrode bandage designed for long-term outpatient electrocardiography (ECG) monitoring. The soft bandage is designed to be attached to the patient chest and miniaturized data collection device is connected to the bandage via Micro-USB connector. The fabricated bandage is tested in short exercise as well as continued long-term (72 hours) monitoring during normal daily activities. The attained quality of the measured ECG signals is fully satisfactory for rhythm-based cardiac analysis also during moderate-intensity exercise. After pre-processing, the signals could be used also for more profound morphological analysis of ECG wave shapes.

  9. Chronic Heart Failure: Contemporary Diagnosis and Management

    PubMed Central

    Ramani, Gautam V.; Uber, Patricia A.; Mehra, Mandeep R.

    2010-01-01

    Chronic heart failure (CHF) remains the only cardiovascular disease with an increasing hospitalization burden and an ongoing drain on health care expenditures. The prevalence of CHF increases with advancing life span, with diastolic heart failure predominating in the elderly population. Primary prevention of coronary artery disease and risk factor management via aggressive blood pressure control are central in preventing new occurrences of left ventricular dysfunction. Optimal therapy for CHF involves identification and correction of potentially reversible precipitants, target-dose titration of medical therapy, and management of hospitalizations for decompensation. The etiological phenotype, absolute decrease in left ventricular ejection fraction and a widening of QRS duration on electrocardiography, is commonly used to identify patients at increased risk of progression of heart failure and sudden death who may benefit from prophylactic implantable cardioverter-defibrillator placement with or without cardiac resynchronization therapy. Patients who transition to advanced stages of disease despite optimal traditional medical and device therapy may be candidates for hemodynamically directed approaches such as a left ventricular assist device; in selected cases, listing for cardiac transplant may be warranted. PMID:20118395

  10. Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring

    PubMed Central

    Ren, Lei; Jiang, Qing; Chen, Keyun; Chen, Zhipeng; Pan, Chengfeng; Jiang, Lelun

    2016-01-01

    A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII) was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG), electrocardiography (ECG), and electroencephalograph (EEG) were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring. PMID:27322278

  11. Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring.

    PubMed

    Ren, Lei; Jiang, Qing; Chen, Keyun; Chen, Zhipeng; Pan, Chengfeng; Jiang, Lelun

    2016-06-17

    A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII) was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG), electrocardiography (ECG), and electroencephalograph (EEG) were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring.

  12. Noninvasive beat-by-beat registration of ventricular late potentials using high resolution electrocardiography.

    PubMed

    Hombach, V; Kebbel, U; Höpp, H W; Winter, U; Hirche, H

    1984-08-01

    We have developed a new high resolution ECG equipment for recording cardiac microvolt potentials from the body surface. Noise reduction has been achieved by specially designed suction electrodes, by spatial averaging of the electrocardiograms from four electrode pairs, using extremely low noise amplifiers, by performing registrations within a Faraday cage, and by teaching the patient to relax during end expiratory breath holding. Fourteen young males (controls) and 30 patients with various cardiac diseases (27 with CHD) were studied. In normals ventricular late potentials were not seen, but in 12/30 patients clearcut diastolic potentials were found. In 7/12 patients with positive findings, late potentials appeared beat-by-beat, in 5/12 patients those signals occurred intermittently, in 11/30 patients questionably, and in the remaining 5/30 patients no late potentials were recorded. One patient with the Romano-Ward syndrome revealed phases with stable beat-by-beat and intermittently occurring ventricular late potentials. These results demonstrate the feasibility of continuous non-invasive recording of ventricular late potentials, whose clinical and prognostic significance remains to be established.

  13. High job control enhances vagal recovery in media work.

    PubMed

    Lindholm, Harri; Sinisalo, Juha; Ahlberg, Jari; Jahkola, Antti; Partinen, Markku; Hublin, Christer; Savolainen, Aslak

    2009-12-01

    Job strain has been linked to increased risk of cardiovascular diseases. In modern media work, time pressures, rapidly changing situations, computer work and irregular working hours are common. Heart rate variability (HRV) has been widely used to monitor sympathovagal balance. Autonomic imbalance may play an additive role in the development of cardiovascular diseases. To study the effects of work demands and job control on the autonomic nervous system recovery among the media personnel. From the cross-sectional postal survey of the employees in Finnish Broadcasting Company (n = 874), three age cohorts (n = 132) were randomly selected for an analysis of HRV in 24 h electrocardiography recordings. In the middle-aged group, those who experienced high job control had significantly better vagal recovery than those with low or moderate control (P < 0.01). Among young and ageing employees, job control did not associate with autonomic recovery. High job control over work rather than low demands seemed to enhance autonomic recovery in middle-aged media workers. This was independent of poor health habits such as smoking, physical inactivity or alcohol consumption.

  14. Wireless Sensor-Based Smart-Clothing Platform for ECG Monitoring

    PubMed Central

    Lin, Chung-Chih; Yu, Yan-Shuo

    2015-01-01

    The goal of this study is to use wireless sensor technologies to develop a smart clothes service platform for health monitoring. Our platform consists of smart clothes, a sensor node, a gateway server, and a health cloud. The smart clothes have fabric electrodes to detect electrocardiography (ECG) signals. The sensor node improves the accuracy of QRS complexes detection by morphology analysis and reduces power consumption by the power-saving transmission functionality. The gateway server provides a reconfigurable finite state machine (RFSM) software architecture for abnormal ECG detection to support online updating. Most normal ECG can be filtered out, and the abnormal ECG is further analyzed in the health cloud. Three experiments are conducted to evaluate the platform's performance. The results demonstrate that the signal-to-noise ratio (SNR) of the smart clothes exceeds 37 dB, which is within the “very good signal” interval. The average of the QRS sensitivity and positive prediction is above 99.5%. Power-saving transmission is reduced by nearly 1980 times the power consumption in the best-case analysis. PMID:26640512

  15. Wireless Sensor-Based Smart-Clothing Platform for ECG Monitoring.

    PubMed

    Wang, Jie; Lin, Chung-Chih; Yu, Yan-Shuo; Yu, Tsang-Chu

    2015-01-01

    The goal of this study is to use wireless sensor technologies to develop a smart clothes service platform for health monitoring. Our platform consists of smart clothes, a sensor node, a gateway server, and a health cloud. The smart clothes have fabric electrodes to detect electrocardiography (ECG) signals. The sensor node improves the accuracy of QRS complexes detection by morphology analysis and reduces power consumption by the power-saving transmission functionality. The gateway server provides a reconfigurable finite state machine (RFSM) software architecture for abnormal ECG detection to support online updating. Most normal ECG can be filtered out, and the abnormal ECG is further analyzed in the health cloud. Three experiments are conducted to evaluate the platform's performance. The results demonstrate that the signal-to-noise ratio (SNR) of the smart clothes exceeds 37 dB, which is within the "very good signal" interval. The average of the QRS sensitivity and positive prediction is above 99.5%. Power-saving transmission is reduced by nearly 1980 times the power consumption in the best-case analysis.

  16. A Smartphone-Based Driver Safety Monitoring System Using Data Fusion

    PubMed Central

    Lee, Boon-Giin; Chung, Wan-Young

    2012-01-01

    This paper proposes a method for monitoring driver safety levels using a data fusion approach based on several discrete data types: eye features, bio-signal variation, in-vehicle temperature, and vehicle speed. The driver safety monitoring system was developed in practice in the form of an application for an Android-based smartphone device, where measuring safety-related data requires no extra monetary expenditure or equipment. Moreover, the system provides high resolution and flexibility. The safety monitoring process involves the fusion of attributes gathered from different sensors, including video, electrocardiography, photoplethysmography, temperature, and a three-axis accelerometer, that are assigned as input variables to an inference analysis framework. A Fuzzy Bayesian framework is designed to indicate the driver’s capability level and is updated continuously in real-time. The sensory data are transmitted via Bluetooth communication to the smartphone device. A fake incoming call warning service alerts the driver if his or her safety level is suspiciously compromised. Realistic testing of the system demonstrates the practical benefits of multiple features and their fusion in providing a more authentic and effective driver safety monitoring. PMID:23247416

  17. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring

    PubMed Central

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-01-01

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized. PMID:29414849

  18. Simulated sudden increase in geomagnetic activity and its effect on heart rate variability: Experimental verification of correlation studies.

    PubMed

    Caswell, Joseph M; Singh, Manraj; Persinger, Michael A

    2016-08-01

    Previous research investigating the potential influence of geomagnetic factors on human cardiovascular state has tended to converge upon similar inferences although the results remain relatively controversial. Furthermore, previous findings have remained essentially correlational without accompanying experimental verification. An exception to this was noted for human brain activity in a previous study employing experimental simulation of sudden geomagnetic impulses in order to assess correlational results that had demonstrated a relationship between geomagnetic perturbations and neuroelectrical parameters. The present study employed the same equipment in a similar procedure in order to validate previous findings of a geomagnetic-cardiovascular dynamic with electrocardiography and heart rate variability measures. Results indicated that potential magnetic field effects on frequency components of heart rate variability tended to overlap with previous correlational studies where low frequency power and the ratio between low and high frequency components of heart rate variability appeared affected. In the present study, a significant increase in these particular parameters was noted during geomagnetic simulation compared to baseline recordings. Copyright © 2016 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  19. Evaluation of cardiovascular anomalies in patients with asymptomatic turner syndrome using multidetector computed tomography.

    PubMed

    Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin; Chung, Woo Yeong

    2013-08-01

    Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed.

  20. A wireless PDA-based physiological monitoring system for patient transport.

    PubMed

    Lin, Yuan-Hsiang; Jan, I-Chien; Ko, Patrick Chow-In; Chen, Yen-Yu; Wong, Jau-Min; Jan, Gwo-Jen

    2004-12-01

    This paper proposes a mobile patient monitoring system, which integrates current personal digital assistant (PDA) technology and wireless local area network (WLAN) technology. At the patient's location, a wireless PDA-based monitor is used to acquire continuously the patient's vital signs, including heart rate, three-lead electrocardiography, and SpO2. Through the WLAN, the patient's biosignals can be transmitted in real-time to a remote central management unit, and authorized medical staffs can access the data and the case history of the patient, either by the central management unit or the wireless devices. A prototype of this system has been developed and implemented. The system has been evaluated by technical verification, clinical test, and user survey. The evaluation of performance yields a high degree of satisfaction (mean = 4.64, standard deviation--SD = 0.53 in a five-point Likert scale) of users who used the PDA-based system for intrahospital transport. The results also show that the wireless PDA model is superior to the currently used monitors both in mobility and in usability, and is, therefore, better suited to patient transport.

  1. Causes of poor performance of horses during training, racing, or showing: 348 cases (1992-1996).

    PubMed

    Martin, B B; Reef, V B; Parente, E J; Sage, A D

    2000-02-15

    To determine results for horses undergoing a high-speed treadmill examination, including videoendoscopy of the pharynx and larynx before and during exercise, echocardiography before and after exercise, and electrocardiography before, during, and after exercise, because of poor performance. Retrospective study. 348 horses. A definitive diagnosis was obtained for 256 (73.5%) horses. One hundred forty-eight horses had dynamic obstruction of the airway during exercise, 33 had clinically important cardiac arrhythmias alone, 22 had a combination of dynamic airway obstruction and clinically important cardiac arrhythmias, 19 had poor cardiac fractional shortening immediately after exercise, 10 had exertional rhabdomyolyis, 15 had clinically apparent lameness, and 9 had other disorders. Thirty-nine of the horses with dynamic obstruction of the airway during exercise had multiple airway abnormalities. Fifty-three horses also had subclinical myopathy Results suggest that a complete evaluation, including a high-speed treadmill examination, should be conducted in horses with poor performance, regardless or whether horses do or do not have a history of abnormal respiratory noises and particularly if the horses have grade-II or -III left laryngeal hemiplegia.

  2. [Telecardiology: Tasks and duties of telemedicine].

    PubMed

    Borbás, János; Forczek, Erzsébet; Sepp, Róbert; Bari, Ferenc

    2017-11-01

    Telemedicine is a young science that integrates innovations of information-technology and telecommunications into medical science. A successful telemedicine procedure should guarantee reduced workload of the healthcare system with well secured and cost-effective processes. Our goal was to collect the development phases of telemedicine projects through existing telecardiology solutions. Subsequent to reviewing international publications we analyzed the past and present situation of blood pressure monitoring, remote diagnostics of electrocardiography, implantable cardioverter defibrillator monitoring and pocket ultrasound devices. In case of new solutions (a) several internationally accepted, confidently reproducible "good practices" are needed for creating (b) guidelines and recommendations of international medical associations. They have to ensure (c) cost-effective work, with well-designed sustainability and (d) patient confidentiality. Improving (e) education for professionals and patients is essential. We recommend to telemedicine developers to use our standards in order to introduce their products more effectively into clinical practice. It is encouraging that current possibilities of telecardiology partly or fully meet the aforementioned criteria. Further development of the topic can contribute to financial sustainability of our healthcare and might be able to resolve limitations of human resources. Orv Hetil. 2017; 158(44): 1741-1746.

  3. A machine learning approach to improve contactless heart rate monitoring using a webcam.

    PubMed

    Monkaresi, Hamed; Calvo, Rafael A; Yan, Hong

    2014-07-01

    Unobtrusive, contactless recordings of physiological signals are very important for many health and human-computer interaction applications. Most current systems require sensors which intrusively touch the user's skin. Recent advances in contact-free physiological signals open the door to many new types of applications. This technology promises to measure heart rate (HR) and respiration using video only. The effectiveness of this technology, its limitations, and ways of overcoming them deserves particular attention. In this paper, we evaluate this technique for measuring HR in a controlled situation, in a naturalistic computer interaction session, and in an exercise situation. For comparison, HR was measured simultaneously using an electrocardiography device during all sessions. The results replicated the published results in controlled situations, but show that they cannot yet be considered as a valid measure of HR in naturalistic human-computer interaction. We propose a machine learning approach to improve the accuracy of HR detection in naturalistic measurements. The results demonstrate that the root mean squared error is reduced from 43.76 to 3.64 beats/min using the proposed method.

  4. Cognitive Collaboration Found in Cardiac Physiology: Study in Classroom Environment

    PubMed Central

    Cowley, Benjamin; Torniainen, Jari; Ukkonen, Antti; Vihavainen, Arto; Puolamäki, Kai

    2016-01-01

    It is known that periods of intense social interaction result in shared patterns in collaborators’ physiological signals. However, applied quantitative research on collaboration is hindered due to scarcity of objective metrics of teamwork effectiveness. Indeed, especially in the domain of productive, ecologically-valid activity such as programming, there is a lack of evidence for the most effective, affordable and reliable measures of collaboration quality. In this study we investigate synchrony in physiological signals between collaborating computer science students performing pair-programming exercises in a class room environment. We recorded electrocardiography over the course of a 60 minute programming session, using lightweight physiological sensors. We employ correlation of heart-rate variability features to study social psychophysiological compliance of the collaborating students. We found evident physiological compliance in collaborating dyads’ heart-rate variability signals. Furthermore, dyads’ self-reported workload was associated with the physiological compliance. Our results show viability of a novel approach to field measurement using lightweight devices in an uncontrolled environment, and suggest that self-reported collaboration quality can be assessed via physiological signals. PMID:27416036

  5. The Telemetric and Holter ECG Warehouse Initiative (THEW): a Data Repository for the Design, Implementation and Validation of ECG-related Technologies

    PubMed Central

    Couderc, Jean-Philippe

    2011-01-01

    We present an initiative supported by the National Heart Lung, and Blood Institute and the Food and Drug Administration for the development of a repository containing continuous electrocardiographic information to be shared with the worldwide scientific community. We believe that sharing data reinforces open scientific inquiry. It encourages diversity of analysis and opinion while promoting new research and facilitating the education of new researchers. In this paper, we present the resources available in this initiative for the scientific community. We describe the set of ECG signals currently hosted and we briefly discuss the associated clinical information (medical history. Disease and study-specific endpoints) and software tools we propose. Currently, the repository contains more than 250GB of data from eight clinical studies including healthy individuals and cardiac patients. This data is available for the development, implementation and validation of technologies related to body-surface ECGs. To conclude, the Telemetric and Holter ECG Warehouse (THEW) is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. PMID:21097349

  6. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring.

    PubMed

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-02-07

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  7. Autonomic nervous activities associated with bruxism events during sleep.

    PubMed

    Nukazawa, Shinichi; Yoshimi, Hidehiro; Sato, Sadao

    2018-03-01

    To confirm the relationship between sleep bruxism (SB) and autonomic nervous (AN) activities to elucidate SB physiology. Subjects included 11 healthy males (mean age, 24.7 ± 2.3 years). These data were recorded in the sleep laboratory using a system composed of a two-axis accelerometer, an infrared camera, electroencephalography, electromyography, and electrocardiography. Time lapse analysis confirmed correlations between AN activity and SB events during sleep in subjects. Relationships between SB strength and length and AN activity were evaluated. Sympathetic nerve (SN) and parasympathetic nerve (PSN) activities occurred significantly in 93.3% of cases (p < 0.01), with similar predictable patterns during SB. Furthermore, SB length and SN activity in seven of the subjects (four subjects, p < 0.05; three subjects p < 0.01), and PSN and SB muscle activities (% maximum voluntary contraction) in five subjects (four subjects, p < 0.05; one subject, p < 0.01) were significantly correlated. The authors believe that SB is closely related to SN as well as PSN activities and may control the AN system.

  8. Advances in diagnostic ultrasonography.

    PubMed

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  9. Screening for Cardiovascular Disease Risk With Resting or Exercise Electrocardiography: Evidence Report and Systematic Review for the US Preventive Services Task Force.

    PubMed

    Jonas, Daniel E; Reddy, Shivani; Middleton, Jennifer Cook; Barclay, Colleen; Green, Joshua; Baker, Claire; Asher, Gary N

    2018-06-12

    Cardiovascular disease (CVD) is the leading cause of death in the United States. To review the evidence on screening asymptomatic adults for CVD risk using electrocardiography (ECG) to inform the US Preventive Services Task Force. MEDLINE, Cochrane Library, and trial registries through May 2017; references; experts; literature surveillance through April 4, 2018. English-language randomized clinical trials (RCTs); prospective cohort studies reporting reclassification, calibration, or discrimination that compared risk assessment using ECG plus traditional risk factors vs traditional risk factors alone. For harms, additional study designs were eligible. Studies of persons with symptoms or a CVD diagnosis were excluded. Dual review of abstracts, full-text articles, and study quality; qualitative synthesis of findings. Mortality, cardiovascular events, reclassification, calibration, discrimination, and harms. Sixteen studies were included (N = 77 140). Two RCTs (n = 1151) found no significant improvement for screening with exercise ECG (vs no screening) in adults aged 50 to 75 years with diabetes for the primary cardiovascular composite outcomes (hazard ratios, 1.00 [95% CI, 0.59-1.71] and 0.85 [95% CI, 0.39-1.84] for each study). No RCTs evaluated screening with resting ECG. Evidence from 5 cohort studies (n = 9582) showed that adding exercise ECG to traditional risk factors such as age, sex, current smoking, diabetes, total cholesterol level, and high-density lipoprotein cholesterol level produced small improvements in discrimination (absolute improvements in area under the curve [AUC] or C statistics, 0.02-0.03, reported by 3 studies); whether calibration or appropriate risk classification improves is uncertain. Evidence from 9 cohort studies (n = 66 407) showed that adding resting ECG to traditional risk factors produced small improvements in discrimination (absolute improvement in AUC or C statistics, 0.001-0.05) and appropriate risk classification for prediction of multiple cardiovascular outcomes, although evidence was limited by imprecision, quality, considerable heterogeneity, and inconsistent use of risk thresholds used for clinical decision making. Total net reclassification improvements ranged from 3.6% (2.7% event; 0.6% nonevent) to 30% (17% event; 19% nonevent) for studies using the Framingham Risk Score or Pooled Cohort Equations base models. Evidence on potential harms (eg, from subsequent angiography or revascularization) in asymptomatic persons was limited. RCTs of screening with exercise ECG found no improvement in health outcomes, despite focusing on higher-risk populations with diabetes. The addition of resting ECG to traditional risk factors accurately reclassified persons, but evidence for this finding had many limitations. The frequency of harms from screening is uncertain.

  10. Atrial Electromechanical Coupling in Patients with Lichen Planus.

    PubMed

    Yaman, Mehmet; Arslan, Uğur; Beton, Osman; Asarcıklı, Lale Dinç; Aksakal, Aytekin; Dogdu, Orhan

    2016-07-01

    A chronic inflammatory disease, lichen planus may cause disturbance of atrial electromechanical coupling and increase the risk of atrial fibrillation. The aim of this study was to evaluate atrial electromechanical delay with both electrocardiography (ECG) and echocardiography in patients with lichen planus (LP). Seventy-two LP patients (43 males [59.7%], mean age: 44.0±16.7 years) were enrolled in this cross-sectional case-control study. The control group was selected in a 1:1 ratio from 70 patients in an age and sex matched manner. P wave dispersion was measured by ECG to show atrial electromechanical delay. All of the patients underwent transthoracic echocardiography for measuring inter- and intra-atrial electromechanical delays. The baseline characteristics of the patients and the control group were similar except for the presence of LP. P-wave dispersion measured by ECG was significantly higher in patients with LP (p<0.001). Patients with LP had significantly prolonged intra- and interatrial electromechanical delays when compared to the control group (p<0.001). In addition, all of these variables were significantly correlated with high sensitive C-reactive protein (hsCRP) levels. Atrial electromechanical coupling, which is significantly correlated with increased hsCRP levels, is impaired in patients with LP.

  11. The effects of diltiazem and metoprolol in QTc prolongation due to amitriptyline intoxication.

    PubMed

    Basol, Nursah; Erbas, Oytun

    2016-01-01

    Amitriptyline, a frequently used tricyclic antidepressant agent, has powerful cardiotoxic effects especially in high doses. Serum and urine levels of amitriptyline dosages are not correlated with severity of toxicity; therefore, it increases the importance of electrocardiography (ECG) abnormalities. The prolongation of QTc can be a predictive marker for cardiotoxicity. Hence, in this study, it is aimed to evaluate possible effects of metoprolol and diltiazem in amitriptyline toxicity. The rats were separated into four groups. First one was control group, the second was the amitriptyline + saline group, third one was the amitriptyline + metoprolol group, and forth one was the amitriptyline + diltiazem group. ECG were recorded on rats under anesthesia. In amitriptyline group, QTc duration was prolonged compared with all other groups. The prolongation of QTc was shorter in amitriptyline + metoprolol group and amitriptyline + diltiazem group than amitriptyline group (p < 0.01 and p < 0.01, respectively). According to the results, it is possible to report ameliorating effects of both metoprolol and diltiazem on QTc prolongation related with amitriptyline intoxication. With further studies, these agents may be used for amitriptyline toxicity and besides, they may be used for patients in cardiovascular risk groups who take amitriptyline treatment regularly. © The Author(s) 2015.

  12. Dispersion durations of P-wave and QT interval in children treated with a ketogenic diet.

    PubMed

    Doksöz, Önder; Güzel, Orkide; Yılmaz, Ünsal; Işgüder, Rana; Çeleğen, Kübra; Meşe, Timur

    2014-04-01

    Limited data are available on the effects of a ketogenic diet on dispersion duration of P-wave and QT-interval measures in children. We searched for the changes in these measures with serial electrocardiograms in patients treated with a ketogenic diet. Twenty-five drug-resistant patients with epilepsy treated with a ketogenic diet were enrolled in this study. Electrocardiography was performed in all patients before the beginning and at the sixth month after implementation of the ketogenic diet. Heart rate, maximum and minimum P-wave duration, P-wave dispersion, and maximum and minimum corrected QT interval and QT dispersion were manually measured from the 12-lead surface electrocardiogram. Minimum and maximum corrected QT and QT dispersion measurements showed nonsignificant increase at month 6 compared with baseline values. Other previously mentioned electrocardiogram parameters also showed no significant changes. A ketogenic diet of 6 months' duration has no significant effect on electrocardiogram parameters in children. Further studies with larger samples and longer duration of follow-up are needed to clarify the effects of ketogenic diet on P-wave dispersion and corrected QT and QT dispersion. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. [Telecardiology: clinical, technical and social aspects. The project of the ASP of Cosenza, Italy].

    PubMed

    Bisignani, Giovanni; De Bonis, Silvana; Bisignani, Antonio; Verta, Antonella

    2016-12-01

    The aim of this paper is to present the project of telecardiology within the ASP of Cosenza, one of the largest provinces of Italy characterized by a particular orography, with difficult and inaccessible roads. The goal of this project is to manage the emergency more efficiently by reducing the time of intervention by bringing the patient not to the nearest hospital, but more importantly to the hospital more appropriately suited to better manage the cardiological emergency. This system also uses the most modern web-based interface technology protected by login and password. The project also provides the integration, supply and installation of advanced and modern central by ensuring efficient screening is carried out using monitors in all the coronary care units of the ASP of Cosenza, networking with electrocardiography of all the point of first medical contact and all the 118 emergency rescue service. By integrating all these procedures and information and making them available to any point in the hospital and territorial network, this project becomes not only a more efficient system for managing cardiac emergency but also a pathway that will guarantee increased care of patients from the onset of symptoms to discharge.

  14. Multiphasic Health Testing in the Clinic Setting

    PubMed Central

    LaDou, Joseph

    1971-01-01

    The economy of automated multiphasic health testing (amht) activities patterned after the high-volume Kaiser program can be realized in low-volume settings. amht units have been operated at daily volumes of 20 patients in three separate clinical environments. These programs have displayed economics entirely compatible with cost figures published by the established high-volume centers. This experience, plus the expanding capability of small, general purpose, digital computers (minicomputers) indicates that a group of six or more physicians generating 20 laboratory appraisals per day can economically justify a completely automated multiphasic health testing facility. This system would reside in the clinic or hospital where it is used and can be configured to do analyses such as electrocardiography and generate laboratory reports, and communicate with large computer systems in university medical centers. Experience indicates that the most effective means of implementing these benefits of automation is to make them directly available to the medical community with the physician playing the central role. Economic justification of a dedicated computer through low-volume health testing then allows, as a side benefit, automation of administrative as well as other diagnostic activities—for example, patient billing, computer-aided diagnosis, and computer-aided therapeutics. PMID:4935771

  15. Accuracy criteria voltage electrocardiography left ventricular hypertrophy to distinguish types of left ventricular hypertrophy geometry

    NASA Astrophysics Data System (ADS)

    Tumbur, O.; Safri, Z.; Hassan, R.

    2018-03-01

    Different types of left ventricular hypertrophy geometry are associated with different risk of cardiovascular disease. The purpose of this study was to determine the role of various ECG voltages of LVH to distinguish the type of LVH geometry. A cross-sectional study from June to November 2015, 100 patients in Adam Malik Hospital Medan. The result of LVH ECG criteria of Sokolow-Lyon was not met then obtained normal left ventricular geometry with 60% sensitivity, 72.22% specificity, and 71% accuracy. The eccentric type of LVH is obtained when the Cornel Voltage is not met; the sensitivity is 25%, specificity 71.88%, and 55% accuracy. Concentric geometric hypertrophy when the RV6/V5> 1 ratio is satisfied, the sensitivity is 55.56%, specificity 56.36%, and 56% accuracy. The RV6/V5>1 ratio was not met, the concentric geometry type of hypertrophy remodeling was determined with a sensitivity of 55.56%, specificity 49.45%, and 50% accuracy. Conclusions, various LVHECG criteria distinguish the type of LVH geometry. Sokolow-Lyon and Cornel Voltage sensitivity and specificity are better than the RV6/V5 ratio.

  16. Cardiac Repolarization Changes in the Children with Breath-Holding Spells

    PubMed Central

    Amoozgar, Hamid; Saleh, Fazl; Farhani, Nahal; Rafiei, Mohammad; Inaloo, Soroor; Asadipooya, Ali-Akbar

    2013-01-01

    Objective Breath-holding spells are known as benign attacks, frequencies of which decrease by the development of the autonomic nervous system. The present study aims to compare the electrocardiographic repolarization in children with breath-holding spells. Methods In this study, QT dispersion, QTc dispersion, T peak to T end dispersion, and P wave dispersion of the twelve-lead surface electrocardiography of fifty children who had breath-holding spells were measured and compared with normal children from April 2011 to August 2012. Findings Forty-four (88%) patients had cyanotic spells, while 6 (12%) had pallid spells. QTc dispersion was increased in the patients with breath-holding spells (148.2±33.1) compared to the healthy children (132±27.3) and the difference was statically significant (P = 0.01). Meanwhile, no statistically significant differences were observed between the patients and the control subjects regarding the other parameters (P > 0.05). Conclusion QTc dispersion was significantly increased in the patients with breath-holding spells compared to normal children and this is a sign of cardiac repolarization abnormality as well as the increased risk of cardiac arrhythmia in patients with breath-holding spells. PMID:24910749

  17. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method.

    PubMed

    Lázzari, J O; Pereira, M; Antunes, C M; Guimarães, A; Moncayo, A; Chávez Domínguez, R; Hernández Pieretti, O; Macedo, V; Rassi, A; Maguire, J; Romero, A

    1998-11-01

    An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG) tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (kappa) index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (kappa = 0.66; SE 0.02). While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  18. Defensive freezing links Hypothalamic-Pituitary-Adrenal-axis activity and internalizing symptoms in humans.

    PubMed

    Niermann, Hannah C M; Figner, Bernd; Tyborowska, Anna; van Peer, Jacobien M; Cillessen, Antonius H N; Roelofs, Karin

    2017-08-01

    The Hypothalamic-Pituitary-Adrenal (HPA)-axis plays an important role in the expression of defensive freezing. Adaptive freezing reactivity, characterized by an immediate increase in acute stress and timely termination upon threat offset or need to act, is essential for adequate stress coping. Blunted HPA-axis activity in animals is associated with blunted freezing reactivity and internalizing symptoms. Despite their potential relevance, it remains unknown whether these mechanisms apply to humans and human psychopathology. Using a well-established method combining electrocardiography and posturography, we assessed freezing before, immediately after, and one hour after a stress induction in 92 human adolescents. In line with animal models, human adolescents showed stress-induced freezing, as quantified by relative reductions in heart rate and body sway after, as compared to before, stress. Moreover, relatively lower basal cortisol was associated with reduced stress-induced freezing reactivity (i.e., less immediate freezing and less recovery). Path analyses showed that decreased freezing recovery in individuals with reduced cortisol levels was associated with increased levels of internalizing symptoms. These findings suggest that reduced freezing recovery may be a promising marker for the etiology of internalizing symptoms. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Concomitant presentation of Anderson-Tawil syndrome and myasthenia gravis in an adult patient: A case report.

    PubMed

    Fan, Rui; Ji, Ruirui; Zou, Wenxin; Wang, Guoliang; Wang, Hu; Penney, Daniel James; Luo, Jin Jun; Fan, Yuxin

    2016-10-01

    Andersen-Tawil syndrome (ATS) is an autosomal dominant, multisystem channelopathy characterized by periodic paralysis, ventricular arrhythmias and distinctive dysmorphic facial or skeletal features. The disorder displays marked intrafamilial variability and incomplete penetrance. Myasthenia gravis (MG) is an autoimmune disorder that demonstrates progressive fatigability, in which the nicotinic acetylcholine receptor (AChR) at neuromuscular junctions is the primary autoantigen. The present study reports a rare case of a 31-year-old woman with a history of morbid obesity and periodic weakness, who presented with hemodynamic instability, cardiogenic shock and facial anomalies. Laboratory results revealed hypokalemia and an elevated anti-AChR antibody expression levels. Electrocardiography demonstrated prolonged QT-interval, ST-elevation, and subsequent third-degree atrioventricular block. Neurological examination revealed bilateral ptosis, horizontal diplopia, dysarthria and generalized weakness. No mutations in the potassium channel inwardly rectifying subfamily J member 2 gene were detected in the present case. The patient was treated with oral potassium supplementation and an acetylcholinesterase inhibitor (pyridostigmine), after which the symptoms were improved. To the best of our knowledge, the present case report was the first to describe concomitant presentation of both ATS and MG, which represents a diagnostic and therapeutic challenge.

  20. Echoguided closed commissurotomy for mitral valve stenosis in a dog.

    PubMed

    Trehiou-Sechi, Emilie; Behr, Luc; Chetboul, Valérie; Pouchelon, Jean-Louis; Castaignet, Maud; Gouni, Vassiliki; Misbach, Charlotte; Petit, Amandine M P; Borenstein, Nicolas

    2011-09-01

    Surgical treatment of mitral stenosis (MS) usually consists of open mitral commissurotomy (MC) or percutaneous balloon MC, which require a cardiopulmonary bypass or transseptal approach, respectively. We describe here the first surgical management of congenital MS in a dog using a less invasive procedure, a surgical closed MC under direct echo guidance. A 5-year-old female Cairn terrier was referred for ascites, weakness, and marked exercise intolerance for 2 months, which was refractory to medical treatment. Diagnosis of severe MS associated with atrial fibrillation (AF) was confirmed by echo-Doppler examination and electrocardiography. Poor response to medical treatment suggested a corrective procedure on the valve was indicated. However, due to the cost and high mortality rate associated with cardiopulmonary bypass, a hybrid MC was recommended. A standard left intercostal thoracotomy was performed and three balloon valvuloplasty catheters of differing diameters were sequentially inserted through the left atrium under direct echo guidance. Transesophageal echocardiography revealed a 62% reduction in the pressure half-time compared to the pre-procedure. Thirteen months after surgery the dog is still doing well with resolution of ascites and a marked improvement of most echo-Doppler variables. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Heart Rate Variability During Early Adaptation to Space

    NASA Technical Reports Server (NTRS)

    Toscano, W. B.; Cowings, P. S.

    1994-01-01

    A recent report hypothesized that episodes of space motion sickness (SMS) were reliably associated with low frequency oscillations (less than 0.03 to less than 0.01 Hz) in heart rate variability. This paper archives a large data set for review of investigators in this field which may facilitate the evaluation of this hypothesis. Continuous recording of Electro-cardiography (ECG) and other measures were made for 6 to 12 hours per day (waking hours) of six Shuttle crewmembers for the first 3 mission days of two separate Shuttle flights. Spectral analyses of heart rate variability during approximately 200 hours of inflight is presented. In addition, nearly 200 hours of data collected on these same individuals during ground tests prior to the mission are presented. The Purpose of this Publication is to document the incidence of low frequency oscillations of heart rate in 4 people exposed to microgravity over a period of five days. In addition, this report contains spectral analyses of heart rate data collected on these same individuals during ground-based mission simulations. By archiving these data in this manner, it is our intention to make this information available to other investigators interested in studying this phenomena.

  2. Month-to-month and year-to-year reproducibility of high frequency QRS ECG signals

    NASA Technical Reports Server (NTRS)

    Batdorf, Niles J.; Feiveson, Alan H.; Schlegel, Todd T.

    2004-01-01

    High frequency electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. Therefore, we prospectively investigated the reproducibility of the root mean squared voltage, kurtosis, and the presence versus absence of reduced amplitude zones in signal averaged 12-lead high frequency QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of root mean squared voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of root mean squared voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. Reduced amplitude zones were also reproducible up to a rate of 87% and 81%, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead high frequency QRS electrocardiograms are sufficiently reproducible for clinical use.

  3. Month-to-Month and Year-to-Year Reproducibility of High Frequency QRS ECG signals

    NASA Technical Reports Server (NTRS)

    Batdorf, Niles; Feiveson, Alan H.; Schlegel, Todd T.

    2006-01-01

    High frequency (HF) electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. We therefore prospectively investigated the reproducibility of the root mean squared (RMS) voltage, kurtosis, and the presence versus absence of reduced amplitude zones (RAzs) in signal averaged 12-lead HF QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of RMS voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of RMS voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. RAzs were also reproducible at a rate of up to 87% and 8 1 %, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead HF QRS electrocardiograms are sufficiently reproducible for clinical use.

  4. Multi-modal pain measurements in infants

    PubMed Central

    Worley, A.; Fabrizi, L.; Boyd, S.; Slater, R.

    2012-01-01

    A non-invasive integrated method was developed to measure neural and behavioural responses to peripheral sensory and noxious stimulation in human infants. The introduction of a novel event-detection interface allows synchronous recording of: (i) muscle and central nervous system activity with surface electromyography (EMG), scalp electroencephalography (EEG) and near-infrared spectroscopy (NIRS); (ii) behavioural responses with video-recording and (iii) autonomic responses (heart rate, oxygen saturation, respiratory rate and cardiovascular activity) with electrocardiography (ECG) and pulse oximetry. The system can detect noxious heel lance and touch stimuli with precision (33 μs and 624 μs respectively) and accuracy (523 μs and 256 μs) and has 100% sensitivity and specificity for both types of stimulation. Its ability to detect response latencies accurately was demonstrated by a shift in latency of the vertex potential of 20.7 ± 15.7 ms (n = 6 infants), following touch of the heel and of the shoulder, reflecting the distance between the two sites. This integrated system has provided reliable and reproducible measurements of responses to sensory and noxious stimulation in human infants on more than 100 test occasions. PMID:22285660

  5. Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring

    PubMed Central

    Lou, Cunguang; Li, Ruikai; Li, Zhaopeng; Liang, Tie; Wei, Zihui; Run, Mingtao; Yan, Xiaobing; Liu, Xiuling

    2016-01-01

    This paper describes the development of a graphene-based dry flexible electrocardiography (ECG) electrode and a portable wireless ECG measurement system. First, graphene films on polyethylene terephthalate (PET) substrates and graphene paper were used to construct the ECG electrode. Then, a graphene textile was synthesized for the fabrication of a wearable ECG monitoring system. The structure and the electrical properties of the graphene electrodes were evaluated using Raman spectroscopy, scanning electron microscopy (SEM), and alternating current impedance spectroscopy. ECG signals were then collected from healthy subjects using the developed graphene electrode and portable measurement system. The results show that the graphene electrode was able to acquire the typical characteristics and features of human ECG signals with a high signal-to-noise (SNR) ratio in different states of motion. A week-long continuous wearability test showed no degradation in the ECG signal quality over time. The graphene-based flexible electrode demonstrates comfortability, good biocompatibility, and high electrophysiological detection sensitivity. The graphene electrode also combines the potential for use in long-term wearable dynamic cardiac activity monitoring systems with convenience and comfort for use in home health care of elderly and high-risk adults. PMID:27809270

  6. Multi-modal pain measurements in infants.

    PubMed

    Worley, A; Fabrizi, L; Boyd, S; Slater, R

    2012-04-15

    A non-invasive integrated method was developed to measure neural and behavioural responses to peripheral sensory and noxious stimulation in human infants. The introduction of a novel event-detection interface allows synchronous recording of: (i) muscle and central nervous system activity with surface electromyography (EMG), scalp electroencephalography (EEG) and near-infrared spectroscopy (NIRS); (ii) behavioural responses with video-recording and (iii) autonomic responses (heart rate, oxygen saturation, respiratory rate and cardiovascular activity) with electrocardiography (ECG) and pulse oximetry. The system can detect noxious heel lance and touch stimuli with precision (33 μs and 624 μs respectively) and accuracy (523 μs and 256 μs) and has 100% sensitivity and specificity for both types of stimulation. Its ability to detect response latencies accurately was demonstrated by a shift in latency of the vertex potential of 20.7 ± 15.7 ms (n=6 infants), following touch of the heel and of the shoulder, reflecting the distance between the two sites. This integrated system has provided reliable and reproducible measurements of responses to sensory and noxious stimulation in human infants on more than 100 test occasions. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Diabetic ketoacidosis producing extreme hyperkalemia in a patient with type 1 diabetes on hemodialysis.

    PubMed

    Yamada, Hodaka; Funazaki, Shunsuke; Kakei, Masafumi; Hara, Kazuo; Ishikawa, San-E

    2017-01-01

    Diabetic ketoacidosis (DKA) is a critical complication of type 1 diabetes associated with water and electrolyte disorders. Here, we report a case of DKA with extreme hyperkalemia (9.0 mEq/L) in a patient with type 1 diabetes on hemodialysis. He had a left frontal cerebral infarction resulting in inability to manage his continuous subcutaneous insulin infusion pump. Electrocardiography showed typical changes of hyperkalemia, including absent P waves, prolonged QRS interval and tented T waves. There was no evidence of total body water deficit. After starting insulin and rapid hemodialysis, the serum potassium level was normalized. Although DKA may present with hypokalemia, rapid hemodialysis may be necessary to resolve severe hyperkalemia in a patient with renal failure. Patients with type 1 diabetes on hemodialysis may develop ketoacidosis because of discontinuation of insulin treatment.Patients on hemodialysis who develop ketoacidosis may have hyperkalemia because of anuria.Absolute insulin deficit alters potassium distribution between the intracellular and extracellular space, and anuria abolishes urinary excretion of potassium.Rapid hemodialysis along with intensive insulin therapy can improve hyperkalemia, while fluid infusions may worsen heart failure in patients with ketoacidosis who routinely require hemodialysis.

  8. Repeat exposure to group A streptococcal M protein exacerbates cardiac damage in a rat model of rheumatic heart disease.

    PubMed

    Gorton, Davina; Sikder, Suchandan; Williams, Natasha L; Chilton, Lisa; Rush, Catherine M; Govan, Brenda L; Cunningham, Madeleine W; Ketheesan, Natkunam

    2016-12-01

    Rheumatic fever and rheumatic heart disease (RF/RHD) develop following repeated infection with group A streptococci (GAS). We used the Rat Autoimmune Valvulitis (RAV) model of RF/RHD to demonstrate that repetitive booster immunization with GAS-derived recombinant M protein (rM5) resulted in an enhanced anti-cardiac myosin antibody response that may contribute to the breaking of immune tolerance leading to RF/RHD and increased infiltration of heart valves by mononuclear cells. With each boost, more inflammatory cells were observed infiltrating heart tissue which could lead to severe cardiac damage. We also found evidence that both complement and anti-M protein antibodies in serum from rM5-immunized rats have the potential to contribute to inflammation in heart valves by activating cardiac endothelium. More importantly, we have demonstrated by electrocardiography for the first time in the RAV model that elongation of P-R interval follows repetitive boost with rM5. Our observations provide experimental evidence for cardiac alterations following repeated exposure to GAS M protein with immunological and electrophysiological features resembling that seen in humans following recurrent GAS infection.

  9. A Comparison of Physiological Signal Analysis Techniques and Classifiers for Automatic Emotional Evaluation of Audiovisual Contents

    PubMed Central

    Colomer Granero, Adrián; Fuentes-Hurtado, Félix; Naranjo Ornedo, Valery; Guixeres Provinciale, Jaime; Ausín, Jose M.; Alcañiz Raya, Mariano

    2016-01-01

    This work focuses on finding the most discriminatory or representative features that allow to classify commercials according to negative, neutral and positive effectiveness based on the Ace Score index. For this purpose, an experiment involving forty-seven participants was carried out. In this experiment electroencephalography (EEG), electrocardiography (ECG), Galvanic Skin Response (GSR) and respiration data were acquired while subjects were watching a 30-min audiovisual content. This content was composed by a submarine documentary and nine commercials (one of them the ad under evaluation). After the signal pre-processing, four sets of features were extracted from the physiological signals using different state-of-the-art metrics. These features computed in time and frequency domains are the inputs to several basic and advanced classifiers. An average of 89.76% of the instances was correctly classified according to the Ace Score index. The best results were obtained by a classifier consisting of a combination between AdaBoost and Random Forest with automatic selection of features. The selected features were those extracted from GSR and HRV signals. These results are promising in the audiovisual content evaluation field by means of physiological signal processing. PMID:27471462

  10. Properties of screen printed electrocardiography smartware electrodes investigated in an electro-chemical cell

    PubMed Central

    2013-01-01

    Background ECG (Electrocardiogram) measurements in home health care demands new sensor solutions. In this study, six different configurations of screen printed conductive ink electrodes have been evaluated with respect to electrode potential variations and electrode impedance. Methods The electrode surfaces consisted of a Ag/AgCl-based ink with a conduction line of carbon or Ag-based ink underneath. On top, a lacquer layer was used to define the electrode area and to cover the conduction lines. Measurements were performed under well-defined electro-chemical conditions in a physiologic saline solution. Results The results showed that all printed electrodes were stable and have a very small potential drift (less than 3 mV/30 min). The contribution to the total impedance was 2% of the set maximal allowed impedance (maximally 1 kΩ at 50 Hz), assuming common values of input impedance and common mode rejection ratio of a regular amplifier. Conclusion Our conclusions are that the tested electrodes show satisfying properties to be used as elements in a skin electrode design that could be suitable for further investigations by applying the electrodes on the skin. PMID:23827015

  11. Ambulatory diffuse optical tomography and multimodality physiological monitoring system for muscle and exercise applications

    NASA Astrophysics Data System (ADS)

    Hu, Gang; Zhang, Quan; Ivkovic, Vladimir; Strangman, Gary E.

    2016-09-01

    Ambulatory diffuse optical tomography (aDOT) is based on near-infrared spectroscopy (NIRS) and enables three-dimensional imaging of regional hemodynamics and oxygen consumption during a person's normal activities. Although NIRS has been previously used for muscle assessment, it has been notably limited in terms of the number of channels measured, the extent to which subjects can be ambulatory, and/or the ability to simultaneously acquire synchronized auxiliary data such as electromyography (EMG) or electrocardiography (ECG). We describe the development of a prototype aDOT system, called NINscan-M, capable of ambulatory tomographic imaging as well as simultaneous auxiliary multimodal physiological monitoring. Powered by four AA size batteries and weighing 577 g, the NINscan-M prototype can synchronously record 64-channel NIRS imaging data, eight channels of EMG, ECG, or other analog signals, plus force, acceleration, rotation, and temperature for 24+ h at up to 250 Hz. We describe the system's design, characterization, and performance characteristics. We also describe examples of isometric, cycle ergometer, and free-running ambulatory exercise to demonstrate tomographic imaging at 25 Hz. NINscan-M represents a multiuse tool for muscle physiology studies as well as clinical muscle assessment.

  12. Role of Copper and Homocysteine in Pressure Overload Heart Failure

    PubMed Central

    Hughes, William M.; Rodriguez, Walter E.; Rosenberger, Dorothea; Chen, Jing; Sen, Utpal; Tyagi, Neetu; Moshal, Karni S.; Vacek, Thomas; Kang, Y. James

    2009-01-01

    Elevated levels of homocysteine (Hcy) (known as hyperhomocysteinemia HHcy) are involved in dilated cardiomyopathy. Hcy chelates copper and impairs copper-dependent enzymes. Copper deficiency has been linked to cardiovascular disease. We tested the hypothesis that copper supplement regresses left ventricular hypertrophy (LVH), fibrosis and endothelial dysfunction in pressure overload DCM mice hearts. The mice were grouped as sham, sham + Cu, aortic constriction (AC), and AC + Cu. Aortic constriction was performed by transverse aortic constriction. The mice were treated with or without 20 mg/kg copper supplement in the diet for 12 weeks. The cardiac function was assessed by echocardiography and electrocardiography. The matrix remodeling was assessed by measuring matrix metalloproteinase (MMP), tissue inhibitor of metalloproteinases (TIMPs), and lysyl oxidase (LOX) by Western blot analyses. The results suggest that in AC mice, cardiac function was improved with copper supplement. TIMP-1 levels decreased in AC and were normalized in AC + Cu. Although MMP-9, TIMP-3, and LOX activity increased in AC and returned to baseline value in AC + Cu, copper supplement showed no significant effect on TIMP-4 activity after pressure overload. In conclusion, our data suggest that copper supplement helps improve cardiac function in a pressure overload dilated cardiomyopathic heart. PMID:18679830

  13. Securing While Sampling in Wireless Body Area Networks With Application to Electrocardiography.

    PubMed

    Dautov, Ruslan; Tsouri, Gill R

    2016-01-01

    Stringent resource constraints and broadcast transmission in wireless body area network raise serious security concerns when employed in biomedical applications. Protecting data transmission where any minor alteration is potentially harmful is of significant importance in healthcare. Traditional security methods based on public or private key infrastructure require considerable memory and computational resources, and present an implementation obstacle in compact sensor nodes. This paper proposes a lightweight encryption framework augmenting compressed sensing with wireless physical layer security. Augmenting compressed sensing to secure information is based on the use of the measurement matrix as an encryption key, and allows for incorporating security in addition to compression at the time of sampling an analog signal. The proposed approach eliminates the need for a separate encryption algorithm, as well as the predeployment of a key thereby conserving sensor node's limited resources. The proposed framework is evaluated using analysis, simulation, and experimentation applied to a wireless electrocardiogram setup consisting of a sensor node, an access point, and an eavesdropper performing a proximity attack. Results show that legitimate communication is reliable and secure given that the eavesdropper is located at a reasonable distance from the sensor node and the access point.

  14. Advances in Photopletysmography Signal Analysis for Biomedical Applications.

    PubMed

    Moraes, Jermana L; Rocha, Matheus X; Vasconcelos, Glauber G; Vasconcelos Filho, José E; de Albuquerque, Victor Hugo C; Alexandria, Auzuir R

    2018-06-09

    Heart Rate Variability (HRV) is an important tool for the analysis of a patient’s physiological conditions, as well a method aiding the diagnosis of cardiopathies. Photoplethysmography (PPG) is an optical technique applied in the monitoring of the HRV and its adoption has been growing significantly, compared to the most commonly used method in medicine, Electrocardiography (ECG). In this survey, definitions of these technique are presented, the different types of sensors used are explained, and the methods for the study and analysis of the PPG signal (linear and nonlinear methods) are described. Moreover, the progress, and the clinical and practical applicability of the PPG technique in the diagnosis of cardiovascular diseases are evaluated. In addition, the latest technologies utilized in the development of new tools for medical diagnosis are presented, such as Internet of Things, Internet of Health Things, genetic algorithms, artificial intelligence and biosensors which result in personalized advances in e-health and health care. After the study of these technologies, it can be noted that PPG associated with them is an important tool for the diagnosis of some diseases, due to its simplicity, its cost⁻benefit ratio, the easiness of signals acquisition, and especially because it is a non-invasive technique.

  15. A Comparison of Physiological Signal Analysis Techniques and Classifiers for Automatic Emotional Evaluation of Audiovisual Contents.

    PubMed

    Colomer Granero, Adrián; Fuentes-Hurtado, Félix; Naranjo Ornedo, Valery; Guixeres Provinciale, Jaime; Ausín, Jose M; Alcañiz Raya, Mariano

    2016-01-01

    This work focuses on finding the most discriminatory or representative features that allow to classify commercials according to negative, neutral and positive effectiveness based on the Ace Score index. For this purpose, an experiment involving forty-seven participants was carried out. In this experiment electroencephalography (EEG), electrocardiography (ECG), Galvanic Skin Response (GSR) and respiration data were acquired while subjects were watching a 30-min audiovisual content. This content was composed by a submarine documentary and nine commercials (one of them the ad under evaluation). After the signal pre-processing, four sets of features were extracted from the physiological signals using different state-of-the-art metrics. These features computed in time and frequency domains are the inputs to several basic and advanced classifiers. An average of 89.76% of the instances was correctly classified according to the Ace Score index. The best results were obtained by a classifier consisting of a combination between AdaBoost and Random Forest with automatic selection of features. The selected features were those extracted from GSR and HRV signals. These results are promising in the audiovisual content evaluation field by means of physiological signal processing.

  16. A New Electrocardiograph Employing the Cathode Ray Oscillograph as the Recording Device

    PubMed Central

    Robertson, Douglas

    1934-01-01

    The advantages of the cathode ray tube as an electrical recording instrument are unique. It has no inherent inertia, so that there is no distortion from this source as there is in every known electro-mechanical recorder. The workings of the cathode ray oscillograph are explained and discussed. Immediate visual observation of the electrocardiogram is obtained by the use of a new fluorescent screen, which is described, and the mechanism of a suitable “time base” circuit for this purpose is explained. Some of the problems associated with the design of an amplifier, distortionless as far as electrocardiography is concerned, are dealt with, including the use of long “time constants” and the employment of a suitable filter circuit. The design of a suitable camera unit (for photographic recording) is discussed. A method of neutralizing interference picked up from alternating current electric light mains is explained and illustrated. The apparatus consists of four easily portable, and mechanically robust, units. The Recorder Unit, the Amplifier Unit, the H.T. (high tension) Supply Unit, and the Camera Unit. ImagesFig. 1Fig. 2Fig. 5Fig. 6Fig. 9Fig. 10 PMID:19989971

  17. Reflections on the role of open source in health information system interoperability.

    PubMed

    Sfakianakis, S; Chronaki, C E; Chiarugi, F; Conforti, F; Katehakis, D G

    2007-01-01

    This paper reflects on the role of open source in health information system interoperability. Open source is a driving force in computer science research and the development of information systems. It facilitates the sharing of information and ideas, enables evolutionary development and open collaborative testing of code, and broadens the adoption of interoperability standards. In health care, information systems have been developed largely ad hoc following proprietary specifications and customized design. However, the wide deployment of integrated services such as Electronic Health Records (EHRs) over regional health information networks (RHINs) relies on interoperability of the underlying information systems and medical devices. This reflection is built on the experiences of the PICNIC project that developed shared software infrastructure components in open source for RHINs and the OpenECG network that offers open source components to lower the implementation cost of interoperability standards such as SCP-ECG, in electrocardiography. Open source components implementing standards and a community providing feedback from real-world use are key enablers of health care information system interoperability. Investing in open source is investing in interoperability and a vital aspect of a long term strategy towards comprehensive health services and clinical research.

  18. Emotional stress as a cause of syncope and torsade de pointes in patients with long QT syndrome.

    PubMed

    Vukmirović, Mihailo; Vukmirović, Irena Tomašević; Angelkov, Lazar; Vukmirović, Filip

    2015-02-01

    Long QT syndrome (LQTS) is a disorder of myocardial repolarization characterized by the prolongation of QT interval and high risk propensity of torsade de pointes (TdP) that can lead to syncope, cardiac arrest and sudden death. Episodes may be provoked by various stimuli depending on the type of the condition. A 25-year-old famele patient was hospitalized due to syncope that occurred immediately after her solo concert, first time in her life. The patient studied solo singing and after intensive preparations the first solo concert was organized. Electrocardiography (ECG) on admission registered frequent ventricular premature beats (VES), followed by polymorphic ventricular tachycardia--TdP that degenerated into ventricular fibrilation (VF). After immediate cardioversion magnesium and beta-blockers were administered. TdP was registered again several times preceded by VES. The corrected QT interval (QTc) was 516 msec. For secondary prevention of sudden cardiac death, a cardioverter defibrillator was implanted, and beta-blockers continued. After a 1-year follow-up there were no recurrent episodes of TdP, and measured QTc was reduced to 484 msec. Patients with syncope following intensive emotional stress should be evaluated for malignant arrhythmias in the context of LQTS.

  19. Ictal EEG fractal dimension in ECT predicts outcome at 2 weeks in schizophrenia.

    PubMed

    Abhishekh, Hulegar A; Thirthalli, Jagadisha; Manjegowda, Anusha; Phutane, Vivek H; Muralidharan, Kesavan; Gangadhar, Bangalore N

    2013-09-30

    Studies of electroconvulsive therapy (ECT) have found an association between ictal electroencephalographic (EEG) measures and clinical outcome in depression. Such studies are lacking in schizophrenia. Consenting schizophrenia patients receiving ECT were assessed using the Brief Psychiatric Rating Scale (BPRS) before and 2 weeks after the start of ECT. The patients' seizure was monitored using EEG. In 26 patients, completely artifact-free EEG derived from the left frontal-pole (FP1) channel and electrocardiography (ECG) were available. The fractal dimension (FD) was computed to assess 4-s EEG epochs, and the maximal value from the earliest ECT session (2nd, 3rd or 4th) was used for analysis. There was a significant inverse correlation between the maximum FD and the total score following 6th ECT. An inverse Inverse correlation was also observed between the maximum FD and the total number of ECTs administered as well as the maximum heart rate (HR) and BPRS scores following 6th ECT. In patients with schizophrenia greater intensity of seizures (higher FD) during initial sessions of ECT is associated with better response at the end of 2 weeks. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. [Clinical picture, diagnostics and prophylaxis of a syndrome in conditions of the Far North].

    PubMed

    Ukhocskiĭ, D M; Tegza, V Iu; Rezvantsev, M V; Vasil'chenko, V V; Belikova, T M

    2014-10-01

    The analysis of a clinical picture barometeosensitivity in a seaside zone of the Far North is carried out in the article. A diagnostic test included the following laboratory assessments: complete blood count, complete urinary analysis, biomedical measurement assessment, immunology blood research and functional renal test; analysis of the level of an electrolyte in the blood and hormone receptor status; and the following instrumental diagnostics: The auscultatory Korotkov's method of determining blood pressure, electrocardiography, variational pulsometry, chest X-ray, mechanocardiography, echocardiography and abdominal ultrasound; and also consultation of ophthalmologist and neuropathologist. Every patient should keep a diary "weather - health" before and after the treatment. Peculiarities of cardiovascular system, vegetative systems and neuroendocrine system of servicemen, coming to the Far North and mechanisms of development of barometeosensivity were revealed. It has been established that atmospheric pressure variation affects systolic and diastolic blood pressure, heart rate, systolic discharge, Kerdo index, effectiveness of myocardial function, end-diastolic and end-systolic volume, level of cholesterol, triglycerides, kalium, adrenalin, triiodothyronine, blood plasma and plasma renin activity in barometeosensetiv servicemen. The criteria of diagnostics of barometeosensivity in conditions of the Far North are suggested. The influence of baromemteosensivity on the combat capability of serviceman is researched.

  1. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    NASA Astrophysics Data System (ADS)

    O'Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-08-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact. This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface.

  2. Oxygen transport and cardiovascular function at extreme altitude: lessons from Operation Everest II

    NASA Technical Reports Server (NTRS)

    Sutton, J. R.; Reeves, J. T.; Groves, B. M.; Wagner, P. D.; Alexander, J. K.; Hultgren, H. N.; Cymerman, A.; Houston, C. S.

    1992-01-01

    Operation Everest II was designed to examine the physiological responses to gradual decompression simulating an ascent of Mt Everest (8,848 m) to an inspired PO2 of 43 mmHg. The principal studies conducted were cardiovascular, respiratory, muscular-skeletal and metabolic responses to exercise. Eight healthy males aged 21-31 years began the "ascent" and six successfully reached the "summit", where their resting arterial blood gases were PO2 = 30 mmHg and PCO2 = 11 mmHg, pH = 7.56. Their maximal oxygen uptake decreased from 3.98 +/- 0.2 L/min at sea level to 1.17 +/- 0.08 L/min at PIO2 43 mmHg. The principal factors responsible for oxygen transport from the atmosphere to tissues were (1) Alveolar ventilation--a four fold increase. (2) Diffusion from the alveolus to end capillary blood--unchanged. (3) Cardiac function (assessed by hemodynamics, echocardiography and electrocardiography)--normal--although maximum cardiac output and heart rate were reduced. (4) Oxygen extraction--maximal with PvO2 14.8 +/- 1 mmHg. With increasing altitude maximal blood and muscle lactate progressively declined although at any submaximal intensity blood and muscle lactate was higher at higher altitudes.

  3. Preclinical evidence of mitochondrial nicotinamide adenine dinucleotide as an effective alarm parameter under hypoxia

    NASA Astrophysics Data System (ADS)

    Shi, Hua; Sun, Nannan; Mayevsky, Avraham; Zhang, Zhihong; Luo, Qingming

    2014-01-01

    Early detection of tissue hypoxia in the intensive care unit is essential for effective treatment. Reduced nicotinamide adenine dinucleotide (NADH) has been suggested to be the most sensitive indicator of tissue oxygenation at the mitochondrial level. However, no experimental evidence comparing the kinetics of changes in NADH and other physiological parameters has been provided. The aim of this study is to obtain the missing data in a systematic and reliable manner. We constructed four acute hypoxia models, including hypoxic hypoxia, hypemic hypoxia, circulatory hypoxia, and histogenous hypoxia, and measured NADH fluorescence, tissue reflectance, cerebral blood flow, respiration, and electrocardiography simultaneously from the induction of hypoxia until death. We found that NADH was not always the first onset parameter responding to hypoxia. The order of responses was mainly affected by the cause of hypoxia. However, NADH reached its alarm level earlier than the other monitored parameters, ranging from several seconds to >10 min. As such, we suggest that the NADH can be used as a hypoxia indicator, although the exact level that should be used must be further investigated. When the NADH alarm is detected, the body still has a chance to recover if appropriate and timely treatment is provided.

  4. A comparative study on the cardiac morphology and vertical jump height of adolescent black South African male and female amateur competitive footballers.

    PubMed

    Gradidge, Philippe Jean-Luc; Constantinou, Demitri

    The aim of this comparative study was to determine the gender differences in cardiac morphology and performance in adolescent black South African footballers. Anthropometry, electrocardiography and echocardiography data were measured in 167 (85 males and 82 females) adolescent black South African footballers (mean age: 14.8 ± 1.3 years). Vertical jump height was used as a performance measure of explosive lower-limb power. The males had less body fat compared with the females (12.1 ± 3.6 vs 16.8 ± 4.1%, p < 0.05), while females had higher left ventricular end-diastolic diameters compared with males (48.7 ± 3.7 vs 40.7 ± 8.1, p < 0.05). Vertical jump height was higher in males (37.2 ± 10.3) compared with females (31.2 ± 8) and was inversely associated with body fat (β = -0.2, p < 0.05) and positively associated with lean mass (β = 0.5, p < 0.05). The findings showed that adolescent black South African male footballers had a performance advantage over females for explosive lower-limb power, which was explained by differences in body composition and not cardiac morphology.

  5. Classification of a Driver's cognitive workload levels using artificial neural network on ECG signals.

    PubMed

    Tjolleng, Amir; Jung, Kihyo; Hong, Wongi; Lee, Wonsup; Lee, Baekhee; You, Heecheon; Son, Joonwoo; Park, Seikwon

    2017-03-01

    An artificial neural network (ANN) model was developed in the present study to classify the level of a driver's cognitive workload based on electrocardiography (ECG). ECG signals were measured on 15 male participants while they performed a simulated driving task as a primary task with/without an N-back task as a secondary task. Three time-domain ECG measures (mean inter-beat interval (IBI), standard deviation of IBIs, and root mean squared difference of adjacent IBIs) and three frequencydomain ECG measures (power in low frequency, power in high frequency, and ratio of power in low and high frequencies) were calculated. To compensate for individual differences in heart response during the driving tasks, a three-step data processing procedure was performed to ECG signals of each participant: (1) selection of two most sensitive ECG measures, (2) definition of three (low, medium, and high) cognitive workload levels, and (3) normalization of the selected ECG measures. An ANN model was constructed using a feed-forward network and scaled conjugate gradient as a back-propagation learning rule. The accuracy of the ANN classification model was found satisfactory for learning data (95%) and testing data (82%). Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. An integrated healthcare information system for end-to-end standardized exchange and homogeneous management of digital ECG formats.

    PubMed

    Trigo, Jesús Daniel; Martínez, Ignacio; Alesanco, Alvaro; Kollmann, Alexander; Escayola, Javier; Hayn, Dieter; Schreier, Günter; García, José

    2012-07-01

    This paper investigates the application of the enterprise information system (EIS) paradigm to standardized cardiovascular condition monitoring. There are many specifications in cardiology, particularly in the ECG standardization arena. The existence of ECG formats, however, does not guarantee the implementation of homogeneous, standardized solutions for ECG management. In fact, hospital management services need to cope with various ECG formats and, moreover, several different visualization applications. This heterogeneity hampers the normalization of integrated, standardized healthcare information systems, hence the need for finding an appropriate combination of ECG formats and a suitable EIS-based software architecture that enables standardized exchange and homogeneous management of ECG formats. Determining such a combination is one objective of this paper. The second aim is to design and develop the integrated healthcare information system that satisfies the requirements posed by the previous determination. The ECG formats selected include ISO/IEEE11073, Standard Communications Protocol for Computer-Assisted Electrocardiography, and an ECG ontology. The EIS-enabling techniques and technologies selected include web services, simple object access protocol, extensible markup language, or business process execution language. Such a selection ensures the standardized exchange of ECGs within, or across, healthcare information systems while providing modularity and accessibility.

  7. Depressed heart rate variability as an independent predictor of death in chronic congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy.

    PubMed

    Ponikowski, P; Anker, S D; Chua, T P; Szelemej, R; Piepoli, M; Adamopoulos, S; Webb-Peploe, K; Harrington, D; Banasiak, W; Wrabec, K; Coats, A J

    1997-06-15

    After acute myocardial infarction, depressed heart rate variability (HRV) has been proven to be a powerful independent predictor of a poor outcome. Although patients with chronic congestive heart failure (CHF) have also markedly impaired HRV, the prognostic value of HRV analysis in these patients remains unknown. The aim of this study was to investigate whether HRV parameters could predict survival in 102 consecutive patients with moderate to severe CHF (90 men, mean age 58 years, New York Heart Association [NYHA] class II to IV, CHF due to idiopathic dilated cardiomyopathy in 24 patients and ischemic heart disease in 78 patients, ejection fraction [EF], 26%; peak oxygen consumption, 16.9 ml/kg/min) after exclusion of patients in atrial fibrilation with diabetes or with chronic renal failure. In the prognostic analysis (Cox proportional-hazards model, Kaplan-Meier survival analysis), the following factors were investigated: age, CHF etiology, NYHA class, EF, peak oxygen consumption, presence of ventricular tachycardia on Holter monitoring, and HRV measures derived from 24-hour electrocardiography monitoring, calculated in the time (standard deviation of all normal RR intervals [SDNN], standard deviation of 5-minute RR intervals [SDANN], mean of all 5-minute standard deviations of RR intervals [SD], root-mean-square of difference of successive RR intervals [rMSSD], and percentage of adjacent RR intervals >50 ms different [pNN50]) and frequency domain (total power [TP], power within low-frequency band [LF], and power within high-frequency band [HF]). During follow-up of 584 +/- 405 days (365 days in all who survived), 19 patients (19%) died (mean time to death: 307 +/- 315 days, range 3 to 989). Cox's univariate analysis identified the following factors to be predictors of death: NYHA (p = 0.003), peak oxygen consumption (p = 0.01), EF (p = 0.02), ventricular tachycardia on Holter monitoring (p = 0.05), and among HRV measures: SDNN (p = 0.004), SDANN (p = 0.003), SD (p = 0.02), and LF (p = 0.003). In multivariate analysis, HRV parameters (SDNN, SDANN, LF) were found to predict survival independently of NYHA functional class, EF, peak oxygen consumption, and ventricular tachycardia on Holter monitoring. The Kaplan-Meier survival curves revealed SDNN < 100 ms to be a useful risk factor; 1-year survival in patients with SDNN < 100 ms was 78% when compared with 95% in those with SDNN > 100 ms (p = 0.008). The coexistence of SDNN < 100 ms and a peak oxygen consumption < 14 ml/kg/min allowed identification of a group of 18 patients with a particularly poor prognosis (1-year survival 63% vs 94% in the remaining patients, p <0.001). We conclude that depressed HRV on 24-hour ambulatory electrocardiography monitoring is an independent risk factor for a poor prognosis in patients with CHF. Whether analysis of HRV could be recommended in the risk stratification for better management of patients with CHF needs further investigation.

  8. Preventive health care, 1999 update: 2. Echocardiography for the detection of a cardiac source of embolus in patients with stroke

    PubMed Central

    Kapral, M K; Silver, F L

    1999-01-01

    OBJECTIVE: To develop guidelines for the use of echocardiography in the investigation of patients with stroke. OPTIONS: (1) Routine transthoracic echocardiography (TTE); (2) routine transesophageal echocardiography (TEE); (3) routine TTE followed by TEE if the TTE findings are noncontributory; (4) selective TTE or TEE in patients with cardiac disease who would not otherwise receive anticoagulant therapy. OUTCOMES: This article reviews the available evidence on the yield of TTE and TEE in detecting cardiac sources of cerebral emboli in patients with stroke, the effectiveness of treatment for cardiac sources of emboli and the effectiveness of screening echocardiography for secondary stroke prevention. EVIDENCE: MEDLINE was searched for relevant articles published from January 1966 to April 1998; also reviewed were additional articles identified from the bibliographies and citations obtained from experts. BENEFITS, HARMS AND COSTS: Echocardiography can detect intracardiac masses (thrombus, vegetation or tumour) in about 4% (with TTE) to 11% (with TEE) of stroke patients. The yield is lower among patients without clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (less than 2%) than among patients with clinical evidence of cardiac disease (less than 19%). The risks of echocardiography to patients are small. TTE has virtually no risks, and TEE is associated with cardiac, pulmonary and bleeding complications in 0.18%. Patients with an identified intracardiac thrombus are at increased risk for embolic events (absolute risk uncertain, range 0%-38%), and this appears to be reduced with anticoagulant therapy (absolute risk reduction uncertain). Anticoagulant therapy carries a risk of major hemorrhage of 1% to 3% per year. The overall effectiveness of echocardiography in the prevention of recurrent stroke is unknown. VALUES: The strength of evidence was evaluated using the methods of the Canadian Task Force on Preventive Health Care. RECOMMENDATIONS: There is fair evidence to recommend echocardiography in patients with stroke and clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (grade B recommendation). There is insufficient evidence to recommend for or against TEE in patients with normal results of TTE (grade C recommendation). There is insufficient evidence to recommend for or against routine echocardiography in patients (including young patients) without clinical cardiac disease (grade C recommendation). Routine echocardiography is not recommended for patients with clinical cardiac disease who have independent indications for or contraindications to anticoagulant therapy (grade D recommendation). There is fair evidence to recommend anticoagulant therapy in patients with stroke and intracardiac thrombus (grade B recommendation). There is insufficient (no) evidence to recommend for or against any specific therapy for patent foramen ovale (grade C recommendation). VALIDATION: The findings of this analysis were reviewed through an iterative process by the members of the Canadian Task Force on Preventive Health Care. PMID:10551199

  9. Evaluation of Dogs with Border Collie Collapse, Including Response to Two Standardized Strenuous Exercise Protocols.

    PubMed

    Taylor, Susan; Shmon, Cindy; Su, Lillian; Epp, Tasha; Minor, Katie; Mickelson, James; Patterson, Edward; Shelton, G Diane

    2016-01-01

    Clinical and metabolic variables were evaluated in 13 dogs with border collie collapse (BCC) before, during, and following completion of standardized strenuous exercise protocols. Six dogs participated in a ball-retrieving protocol, and seven dogs participated in a sheep-herding protocol. Findings were compared with 16 normal border collies participating in the same exercise protocols (11 retrieving, five herding). Twelve dogs with BCC developed abnormal mentation and/or an abnormal gait during evaluation. All dogs had post-exercise elevations in rectal temperature, pulse rate, arterial blood pH, PaO2, and lactate, and decreased PaCO2 and bicarbonate, as expected with strenuous exercise, but there were no significant differences between BCC dogs and normal dogs. Electrocardiography demonstrated sinus tachycardia in all dogs following exercise. Needle electromyography was normal, and evaluation of muscle biopsy cryosections using a standard panel of histochemical stains and reactions did not reveal a reason for collapse in 10 dogs with BCC in which these tests were performed. Genetic testing excluded the dynamin-1 related exercise-induced collapse mutation and the V547A malignant hyperthermia mutation as the cause of BCC. Common reasons for exercise intolerance were eliminated. Although a genetic basis is suspected, the cause of collapse in BCC was not determined.

  10. Unusual Survival of Anomalous Left Coronary Artery From the Pulmonary Artery With Severe Rheumatic Mitral Stenosis in Septuagenarian Women: Foes Becoming Friends?

    PubMed

    Sinha, Santosh Kumar; Khanra, Dibbendhu; Jha, Mukesh Jitendra; Singh, Karandeep; Razi, Mahamdulla; Goel, Amit; Mishra, Vikas; Asif, Mohammad; Sachan, Mohit; Afdaali, Nasar; Kumar, Ashutosh; Thakur, Ramesh; Krishna, Vinay; Pandey, Umeshwar; Varma, Chandra Mohan

    2016-10-01

    ALCAPA syndrome (anomalous origin of the left coronary artery from the pulmonary artery) is a rare disease but lethal with clinical expression from myocardial infarction, congestive heart failure to death during early infancy and unusual survival to adulthood. We report a 73-year-old woman with ALCAPA who presented with exertional dyspnea (NYHA functional class II) over past 2 years. Physical examination revealed soft S, long mid diastolic rumbling murmur and apical pan-systolic murmur. Electrocardiography displayed biatrial enlargement and poor R progression and normal sinus rhythm. Echocardiography established calcified severe mitral stenosis (MS), presence of continuous flow entering the pulmonary trunk, turbulent continuous flow in inter-ventricular septum with left to right shunt in contrast echocardiography and normal systolic function. Coronary angiogram showed absence of left coronary artery (LCA) originating from aorta, dilated and tortuous right coronary artery (RCA) and abundant Rentrop grade 3 intercoronary collateral communicating with LCA originating from pulmonary trunk which was also confirmed on coronary CT angiogram thus establishing diagnosis of ALCAPA. It is exceedingly rare to be associated with severe MS. However, such a long survival in our patient can be explained by the severe pulmonary arterial hypertension which may be contributing to lesser coronary steal.

  11. Metoprolol and diltiazem ameliorate ziprasidone-induced prolonged corrected QT interval in rats.

    PubMed

    Erbas, Oytun; Yilmaz, Mustafa

    2015-12-01

    Ziprasidone, an atypical antipsychotic agent, has been shown to increase the corrected QT (QTc) interval in some patients. The aim of this study was to reveal the effects of metoprolol and diltiazem on ziprasidone drug-induced prolonged QTc interval. A total of 24 rats were equally divided into the following four groups: the first group was used as the control and received 1 mL/kg saline; 3 mg/kg ziprasidone and saline were administered to the second group; 3 mg/kg ziprasidone and 1 mg/kg metoprolol were administered to the third group and 3 mg/kg ziprasidone and 2 mg/kg diltiazem were administered to the fourth group. Two hours following application of the drugs, the QTc was calculated by performing electrocardiography in derivation (D)I. The duration of QTc interval was compared among the four groups. The mean QTc intervals were significantly increased in the third and fourth groups compared with the second group (p < 0.0005 and p < 0.0001, respectively). The study demonstrated the effectiveness of metoprolol and diltiazem in the prevention of ziprasidone-induced elongation in the QTc interval. Both metoprolol and diltiazem may be considered in the prophylactic therapy of high-risk patients who are using ziprasidone. © The Author(s) 2013.

  12. Evaluating compliance with institutional preoperative testing guidelines for minimal-risk patients undergoing elective surgery.

    PubMed

    Siriussawakul, Arunotai; Nimmannit, Akarin; Rattana-arpa, Sirirat; Chatrattanakulchai, Siritda; Saengtawan, Puttachard; Wangdee, Aungsumat

    2013-01-01

    Few investigations preoperatively are important for low-risk patients. This study was designed to determine the level of compliance with preoperative investigation guidelines for ASA I patients undergoing elective surgery. Secondary objectives included the following: to identify common inappropriate investigations, to evaluate the impact of abnormal testing on patient management, to determine factors affecting noncompliant tests, and to estimate unnecessary expenditure. This retrospective study was conducted on adult patients over a one-year period. The institute's guidelines recommend tests according to the patients' age groups: a complete blood count (CBC) for those patients aged 18-45; CBC, chest radiograph (CXR) and electrocardiography (ECG) for those aged 46-60; and CBC, CXR, ECG, electrolytes, blood glucose, blood urea nitrogen (BUN), and creatinine (Cr) for patients aged 61-65. The medical records of 1,496 patients were reviewed. Compliant testing was found in only 12.1% (95% CI, 10.5-13.9). BUN and Cr testings were the most frequently overprescribed tests. Overinvestigations tended to be performed on major surgery and younger patients. Overall, overinvestigation incurred an estimated cost of US 200,000 dollars during the study period. The need to utilize the institution's preoperative guidelines should be emphasized in order to decrease unnecessary testing and the consequential financial burden.

  13. Prenatal stress and balance of the child's cardiac autonomic nervous system at age 5-6 years.

    PubMed

    van Dijk, Aimée E; van Eijsden, Manon; Stronks, Karien; Gemke, Reinoud J B J; Vrijkotte, Tanja G M

    2012-01-01

    Autonomic nervous system (ANS) misbalance is a potential causal factor in the development of cardiovascular disease. The ANS may be programmed during pregnancy due to various maternal factors. Our aim is to study maternal prenatal psychosocial stress as a potential disruptor of cardiac ANS balance in the child. Mothers from a prospective birth cohort (ABCD study) filled out a questionnaire at gestational week 16 [IQR 12-20], that included validated instruments for state anxiety, depressive symptoms, pregnancy-related anxiety, parenting daily hassles and job strain. A cumulative stress score was also calculated (based on 80(th) percentiles). Indicators of cardiac ANS in the offspring at age 5-6 years are: pre-ejection period (PEP), heart rate (HR), respiratory sinus arrhythmia (RSA) and cardiac autonomic balance (CAB), measured with electrocardiography and impedance cardiography in resting supine and sitting positions. 2,624 mother-child pairs, only single births, were available for analysis. The stress scales were not significantly associated with HR, PEP, RSA and CAB (p≥0.17). Accumulation of maternal stress was also not associated with HR, PEP, RSA and CAB (p≥0.07). Results did not support the hypothesis that prenatal maternal psychosocial stress deregulates cardiac ANS balance in the offspring, at least in rest, and at the age of five-six years.

  14. Pre-Participation Musculoskeletal and Cardiac Screening of Male Athletes in the United Arab Emirates

    PubMed Central

    Alattar, A; Ghani, S; Mahdy, N; Hussain, H; Maffulli, N

    2014-01-01

    This study presents the results of pre-participation musculoskeletal and cardiac screening using the Lausanne recommendations, which include a personal and family history, physical examination and electrocardiography. Cross sectional study using the Lausanne screenings and the European Society of Cardiology (ESC) recommendations carried out at Al-Ahli club in Dubai, United Arab Emirates. 230 male athletes participating in organised sports were included. Exclusion criteria were those under 14 or over 35 years old, females and athletes with established cardiovascular disease. Primary outcome are the results of Lausanne screening with outline of the negative, positive and false positive results and number needed to screen. Secondary outcomes include the results of musculoskeletal and neurological screening. A total of 174 (76%) athletes had a negative screening result. Fifty-four athletes (23%) underwent additional testing. Forty-seven athletes (20.4%) had false positive screening results. Seven athletes (3%) had a positive screening result and four athletes (2%) were restricted from sport. The number of athletes needed to screen to detect one lethal cardiovascular condition was 33 athletes. The Lausanne recommendations are well suited for the United Arab Emirates. The number needed to screen to detect one athlete with serious cardiovascular disease is acceptable at 33. PMID:24809035

  15. Neural activity induced by visual food stimuli presented out of awareness: a preliminary magnetoencephalography study.

    PubMed

    Takada, Katsuko; Ishii, Akira; Matsuo, Takashi; Nakamura, Chika; Uji, Masato; Yoshikawa, Takahiro

    2018-02-15

    Obesity is a major public health problem in modern society. Appetitive behavior has been proposed to be partially driven by unconscious decision-making processes and thus, targeting the unconscious cognitive processes related to eating behavior is essential to develop strategies for overweight individuals and obese patients. Here, we presented food pictures below the threshold of awareness to healthy male volunteers and examined neural activity related to appetitive behavior using magnetoencephalography. We found that, among participants who did not recognize food pictures during the experiment, an index of heart rate variability assessed by electrocardiography (low-frequency component power/high-frequency component power ratio, LF/HF) just after picture presentation was increased compared with that just before presentation, and the increase in LF/HF was negatively associated with the score for cognitive restraint of food intake. In addition, increased LF/HF was negatively associated with increased alpha band power in Brodmann area (BA) 47 caused by food pictures presented below the threshold of awareness, and level of cognitive restraint was positively associated with increased alpha band power in BA13. Our findings may provide valuable clues to the development of methods assessing unconscious regulation of appetite and offer avenues for further study of the neural mechanisms related to eating behavior.

  16. Analysis of physiological signals for recognition of boredom, pain, and surprise emotions.

    PubMed

    Jang, Eun-Hye; Park, Byoung-Jun; Park, Mi-Sook; Kim, Sang-Hyeob; Sohn, Jin-Hun

    2015-06-18

    The aim of the study was to examine the differences of boredom, pain, and surprise. In addition to that, it was conducted to propose approaches for emotion recognition based on physiological signals. Three emotions, boredom, pain, and surprise, are induced through the presentation of emotional stimuli and electrocardiography (ECG), electrodermal activity (EDA), skin temperature (SKT), and photoplethysmography (PPG) as physiological signals are measured to collect a dataset from 217 participants when experiencing the emotions. Twenty-seven physiological features are extracted from the signals to classify the three emotions. The discriminant function analysis (DFA) as a statistical method, and five machine learning algorithms (linear discriminant analysis (LDA), classification and regression trees (CART), self-organizing map (SOM), Naïve Bayes algorithm, and support vector machine (SVM)) are used for classifying the emotions. The result shows that the difference of physiological responses among emotions is significant in heart rate (HR), skin conductance level (SCL), skin conductance response (SCR), mean skin temperature (meanSKT), blood volume pulse (BVP), and pulse transit time (PTT), and the highest recognition accuracy of 84.7% is obtained by using DFA. This study demonstrates the differences of boredom, pain, and surprise and the best emotion recognizer for the classification of the three emotions by using physiological signals.

  17. New Additions to the Toolkit for Forward/Inverse Problems in Electrocardiography within the SCIRun Problem Solving Environment.

    PubMed

    Coll-Font, Jaume; Burton, Brett M; Tate, Jess D; Erem, Burak; Swenson, Darrel J; Wang, Dafang; Brooks, Dana H; van Dam, Peter; Macleod, Rob S

    2014-09-01

    Cardiac electrical imaging often requires the examination of different forward and inverse problem formulations based on mathematical and numerical approximations of the underlying source and the intervening volume conductor that can generate the associated voltages on the surface of the body. If the goal is to recover the source on the heart from body surface potentials, the solution strategy must include numerical techniques that can incorporate appropriate constraints and recover useful solutions, even though the problem is badly posed. Creating complete software solutions to such problems is a daunting undertaking. In order to make such tools more accessible to a broad array of researchers, the Center for Integrative Biomedical Computing (CIBC) has made an ECG forward/inverse toolkit available within the open source SCIRun system. Here we report on three new methods added to the inverse suite of the toolkit. These new algorithms, namely a Total Variation method, a non-decreasing TMP inverse and a spline-based inverse, consist of two inverse methods that take advantage of the temporal structure of the heart potentials and one that leverages the spatial characteristics of the transmembrane potentials. These three methods further expand the possibilities of researchers in cardiology to explore and compare solutions to their particular imaging problem.

  18. [Hemodynamics variation in hypertensive pilots of polar transport aviation on different flight phases].

    PubMed

    Solov'eva, K B; Dolbin, I V; Koroleva, E B

    2013-01-01

    The purpose was to study in-flight blood pressure (BP) and heart rate (HR) in polar transport aviation pilots afflicted with essential hypertension. A total of 30 pilots were distributed into 2 groups: hypertensive pilots and those who, though generally healthy were, because of some conditions and lifestyle, predisposed to the cardiovascular risk (CVR). The examination included establishment of personal CVR factors, electrocardiography, bicycle ergometry, echocardiography, off-duty 24-hour BP and HR monitoring, and in-flight BP and HR monitoring. Maximum BP and HR values were higher in hypertensive pilots as compared with the control group. In the first group, maximum systolic BP (sBP) on the rise measured 202 mm Hg vs. 179 mm Hg in the control group. The highest HR on the rise was also registered in the first group (164 beats/min vs. 127 beats/min in the control). At landing, maximum sBP and HR made up 253 and 163 mm Hg, 150 and 141 beats/min values in groups first and second, respectively. To summarize, in the harsh weather conditions of Far North hypertensive pilots experience particularly heavy hemodynamic stresses during flight and, consequently, must be allowed to fly only if their hypertension is under control.

  19. The Cardiovascular Effect of Single Injection and Toxicologic Effects of Repetitive 2-Week Intravenous Administration of Activin A/BMP-2 Chimera in Beagle Dog.

    PubMed

    Lee, Jae Hyup; Choe, Senyon; Han, Shihuan

    2018-02-01

    This study was performed for the purpose to evaluate the effect of activin A/BMP-2 chimera (AB204) on cardiovascular system and toxicological effect in beagle dogs. When administered AB204 at the dose of 0.32 mg/kg via intravenous injection in beagle dogs, there were no changes in systolic, diastolic and mean blood pressure as well as in pulse rate, in addition that there were no differences in ORS complex, PR interval, R-R interval, QT interval and QTcV interval on the electrocardiography. Also, when administered AB204 at the doses of 0.25 and 0.5 mg/kg/day via repetitive intravenous injection for 2 weeks, it did not cause any significant changes in general symptoms, weight, food intake, ophthalmologic abnormality, urine, hematology, serum biochemistry, organ weight and autopsy values. Therefore, AB204 did not affect cardiovascular functions including blood pressure, pulse rate and ECG, when administered at the dose of ≤0.32 mg/kg via single intravenous injection in male beagle dogs. When it was administered at the dose of 0.5 mg/kg repetitive intravenous injection for 2 weeks, it did not show any toxicity.

  20. Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis.

    PubMed

    Lee, W K; Yoon, H; Park, K S

    2016-07-01

    Since heart rate variability (HRV) analysis is widely used to evaluate the physiological status of the human body, devices specifically designed for such applications are needed. To this end, we developed a smart electrocardiography (ECG) patch. The smart patch measures ECG using three electrodes integrated into the patch, filters the measured signals to minimize noise, performs analog-to-digital conversion, and detects R-peaks. The measured raw ECG data and the interval between the detected R-peaks can be recorded to enable long-term HRV analysis. Experiments were performed to evaluate the performance of the built-in R-wave detection, robustness of the device under motion, and applicability to the evaluation of mental stress. The R-peak detection results obtained with the device exhibited a sensitivity of 99.29%, a positive predictive value of 100.00%, and an error of 0.71%. The device also exhibited less motional noise than conventional ECG recording, being stable up to a walking speed of 5 km/h. When applied to mental stress analysis, the device evaluated the variation in HRV parameters in the same way as a normal ECG, with very little difference. This device can help users better understand their state of health and provide physicians with more reliable data for objective diagnosis.

  1. Accelerometer-Based Method for Extracting Respiratory and Cardiac Gating Information for Dual Gating during Nuclear Medicine Imaging

    PubMed Central

    Pänkäälä, Mikko; Paasio, Ari

    2014-01-01

    Both respiratory and cardiac motions reduce the quality and consistency of medical imaging specifically in nuclear medicine imaging. Motion artifacts can be eliminated by gating the image acquisition based on the respiratory phase and cardiac contractions throughout the medical imaging procedure. Electrocardiography (ECG), 3-axis accelerometer, and respiration belt data were processed and analyzed from ten healthy volunteers. Seismocardiography (SCG) is a noninvasive accelerometer-based method that measures accelerations caused by respiration and myocardial movements. This study was conducted to investigate the feasibility of the accelerometer-based method in dual gating technique. The SCG provides accelerometer-derived respiratory (ADR) data and accurate information about quiescent phases within the cardiac cycle. The correct information about the status of ventricles and atria helps us to create an improved estimate for quiescent phases within a cardiac cycle. The correlation of ADR signals with the reference respiration belt was investigated using Pearson correlation. High linear correlation was observed between accelerometer-based measurement and reference measurement methods (ECG and Respiration belt). Above all, due to the simplicity of the proposed method, the technique has high potential to be applied in dual gating in clinical cardiac positron emission tomography (PET) to obtain motion-free images in the future. PMID:25120563

  2. Hybrid-Aware Model for Senior Wellness Service in Smart Home.

    PubMed

    Jung, Yuchae

    2017-05-22

    Smart home technology with situation-awareness is important for seniors to improve safety and security. With the development of context-aware computing, wearable sensor technology, and ubiquitous computing, it is easier for seniors to manage their health problem in smart home environment. For monitoring senior activity in smart home, wearable, and motion sensors-such as respiration rate (RR), electrocardiography (ECG), body temperature, and blood pressure (BP)-were used for monitoring movements of seniors. For context-awareness, environmental sensors-such as gas, fire, smoke, dust, temperature, and light sensors-were used for senior location data collection. Based on senior activity, senior health status can be classified into positive and negative. Based on senior location and time, senior safety is classified into safe and emergency. In this paper, we propose a hybrid inspection service middleware for monitoring elderly health risk based on senior activity and location. This hybrid-aware model for the detection of abnormal status of seniors has four steps as follows: (1) data collection from biosensors and environmental sensors; (2) monitoring senior location and time of stay in each location using environmental sensors; (3) monitoring senior activity using biometric data; finally, (4) expectation-maximization based decision-making step recommending proper treatment based on a senior health risk ratio.

  3. Case report: patient with Weil’s disease, chest pain, hepatitis b, hepatorenal syndrome, and electrolyte imbalance

    NASA Astrophysics Data System (ADS)

    Mustopa; Susilo, R. S. B.; Arifin; Redhono, D.; Sumandjar, T.

    2018-03-01

    A 48-years-old man was hospitalized due to febrile for 5 days accompanied by headache and left chest pain radiating into the back. Pain calf, abdominal pain and tea color urine has occured since 1 week before admission. Physical examination revealed temperature 38.5° C, conjungtival suffusion, jaundice sclera, irregularheart sound, hepatomegaly, gastrocnemius tenderness, Faine score 23. Laboratory tests showed leukocytosis, thrombocytopenia, elevated transaminase enzyme, ureum 181 mg/dl, creatinine 4.3 mg/dl, albumin 2.4 g/dl, sodium 110 mmol/L, potassium 2.3 mmol/L, reactive HbsAg, CKMB 68.06 ng/ml, increased HBV-DNA, negative IgM anti Leptospira. MAT demonstrated 4 positive serovar. Electrocardiography revealed AF rapid ventrikel response. Chest x-ray showed cardiomegaly. Abdominal ultrasound revealed hepatomegaly with chronic parenchimal liver disease, renal insuficiency. Fibroscan showed severe fibrosis. Patient was diagnosed with Weil’s disease and hepatorenal syndrome as complication. Patient was given clavulanate amoxicillin injections. This patient was not dialysis, only fluid balance monitoring and checked ureum-creatinine per 3 days, and there was improvement of ureum-creatinine. Hepatorenal syndrome in Weil’s disease contributed to electrolyte imbalance. In addition, chronic hepatitis B on this patient was treated with tenofovir.

  4. Validation of a Novel Digital Tool in Automatic Scoring of an Online ECG Examination at an International Cardiology Meeting.

    PubMed

    Quinn, Kieran L; Crystal, Eugene; Lashevsky, Ilan; Arouny, Banafsheh; Baranchuk, Adrian

    2016-07-01

    We have previously developed a novel digital tool capable of automatically recognizing correct electrocardiography (ECG) diagnoses in an online exam and demonstrated a significant improvement in diagnostic accuracy when utilizing an inductive-deductive reasoning strategy over a pattern recognition strategy. In this study, we sought to validate these findings from participants at the International Winter Arrhythmia School meeting, one of the foremost electrophysiology events in Canada. Preregistration to the event was sent by e-mail. The exam was administered on day 1 of the conference. Results and analysis were presented the following morning to participants. Twenty-five attendees completed the exam, providing a total of 500 responses to be marked. The online tool accurately identified 195 of a total of 395 (49%) correct responses (49%). In total, 305 responses required secondary manual review, of which 200 were added to the correct responses pool. The overall accuracy of correct ECG diagnosis for all participants was 69% and 84% when using pattern recognition or inductive-deductive strategies, respectively. Utilization of a novel digital tool to evaluate ECG competency can be set up as a workshop at international meetings or educational events. Results can be presented during the sessions to ensure immediate feedback. © 2015 Wiley Periodicals, Inc.

  5. Prediction and early detection of delirium in the intensive care unit by using heart rate variability and machine learning.

    PubMed

    Oh, Jooyoung; Cho, Dongrae; Park, Jaesub; Na, Se Hee; Kim, Jongin; Heo, Jaeseok; Shin, Cheung Soo; Kim, Jae-Jin; Park, Jin Young; Lee, Boreom

    2018-03-27

    Delirium is an important syndrome found in patients in the intensive care unit (ICU), however, it is usually under-recognized during treatment. This study was performed to investigate whether delirious patients can be successfully distinguished from non-delirious patients by using heart rate variability (HRV) and machine learning. Electrocardiography data of 140 patients was acquired during daily ICU care, and HRV data were analyzed. Delirium, including its type, severity, and etiologies, was evaluated daily by trained psychiatrists. HRV data and various machine learning algorithms including linear support vector machine (SVM), SVM with radial basis function (RBF) kernels, linear extreme learning machine (ELM), ELM with RBF kernels, linear discriminant analysis, and quadratic discriminant analysis were utilized to distinguish delirium patients from non-delirium patients. HRV data of 4797 ECGs were included, and 39 patients had delirium at least once during their ICU stay. The maximum classification accuracy was acquired using SVM with RBF kernels. Our prediction method based on HRV with machine learning was comparable to previous delirium prediction models using massive amounts of clinical information. Our results show that autonomic alterations could be a significant feature of patients with delirium in the ICU, suggesting the potential for the automatic prediction and early detection of delirium based on HRV with machine learning.

  6. Effect of experimental coronary sinus ligation on myocardial structure and function in the presence or absence of structural heart disease: an insight for the interventional electrophysiologist.

    PubMed

    Diab, Osama Ali; Amer, Mohammed Said; Salah El-Din, Rania Ahmed

    2016-12-01

    To study the effect of coronary sinus (CS) occlusion on normal hearts and hearts with structural disease. We included 32 dogs, divided into 4 groups: (1) CS ligation (CSL): subjected to CSL; (2) control group: no intervention; (3) MI-CSL group: subjected to myocardial infarction (MI) induction followed by CSL after 1 week; and (4) MI-control group: subjected to MI induction, then open thoracotomy after 1 week without CSL. Electrocardiography, echocardiography, histopathology, and immunohistochemistry were done before and after CSL. In CSL group, there were no significant electrocardiographic or echocardiographic changes after CSL, although there was interstitial oedema that decreased after 1 week with the appearance of Thebesian vessels and positive staining for vascular endothelial growth factor. In MI-CSL group, there was significant increase in left ventricular (LV) end-systolic diameter (P = 02), decrease in LV fractional shortening (P = 0.0001), and LV ejection fraction (P = 0.002) in comparison with MI-control group, associated with severe myocardial degeneration. Acute CS occlusion could be compensated in normal hearts, but may be detrimental in the presence of structural heart disease. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  7. Near-infrared light-responsive nanomaterials in cancer therapeutics.

    PubMed

    Shanmugam, Vijayakumar; Selvakumar, S; Yeh, Chen-Sheng

    2014-09-07

    Noninvasive techniques, such as breath tests (urea breath test), blood pressure measurements using a sphygmomanometer and electrocardiography, were employed by a physician to perform classical diagnosis. The use of state-of-the-art noninvasive therapies at the organ level in modern medicine has gradually become possible. However, cancer treatment demands spatially and temporally controlled noninvasive therapy at the cell level because nonspecific toxicity often causes complicated side effects. To increase survival in cancer patients further, combination therapy and combination drugs are explored which demand high specificity to avoid combined-drug side effects. We believe that high specificity could be obtained by implementing near-infrared (NIR) light-assisted nanoparticles in photothermal therapy, chemotherapy, and photodynamic therapy. To refine this therapy and subsequently achieve high efficiency, novel nanomaterials have been designed and modified either to enhance the uptake and drug delivery to the cancer site, or control treatment to administer therapy efficiently. These modifications and developments have been demonstrated to achieve spatial and temporal control when conducting an in vivo xenograft, because the NIR light penetrated effectively the biological tissue. The nanoplatforms discussed in this review are grouped under the following subheadings: Au nanorods (NRs), Au nanoshells, other Au-related nanomaterials, graphene oxide, upconversion nanoparticles, and other related materials (including materials such as CuS, Fe3O4-related systems, and carbon nanotubes (CNTs)).

  8. A review of the epidemiologic literature on the role of environmental arsenic exposure and cardiovascular diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, C.-H.; Hsiao, C.K.; Chen, C.-L.

    2007-08-01

    Cardiovascular disease is the leading cause of mortality worldwide. Arsenic is a ubiquitous metalloid in the crust of the earth. Chronic arsenic poisoning is becoming an emerging epidemic in Asia. Epidemiological studies have shown that chronic arsenic poisoning through ingestion of arsenic-contaminated water is associated with various cardiovascular diseases in dose-response relationships. These cardiovascular disorders include carotid atherosclerosis detected by ultrasonography, impaired microcirculation, prolonged QT interval and increased QT dispersion in electrocardiography, and clinical outcomes such as hypertension, blackfoot disease (a unique peripheral vascular disease endemic in southwestern Taiwan), coronary artery disease and cerebral infarction. Chronic arsenic poisoning is anmore » independent risk factor for cardiovascular disease. The adverse cardiovascular effects of long-term arsenic exposure may be persistent and/or irreversible. Arsenic-induced cardiovascular diseases in human population may result from the interaction among genetic, environment and nutritional factors. The major adverse cardiovascular effect of chronic arsenic poisoning has been established qualitatively and quantitatively in the high arsenic exposure areas, but the low-dose effect of arsenic on cardiovascular diseases remains to be explored. Cardiovascular death is the major cause of mortality worldwide, and a small increased risk may imply a large quantity of excess mortality.« less

  9. IEEE-802.15.4-based low-power body sensor node with RF energy harvester.

    PubMed

    Tran, Thang Viet; Chung, Wan-Young

    2014-01-01

    This paper proposes the design and implementation of a low-voltage and low-power body sensor node based on the IEEE 802.15.4 standard to collect electrocardiography (ECG) and photoplethysmography (PPG) signals. To achieve compact size, low supply voltage, and low power consumption, the proposed platform is integrated into a ZigBee mote, which contains a DC-DC booster, a PPG sensor interface module, and an ECG front-end circuit that has ultra-low current consumption. The input voltage of the proposed node is very low and has a wide range, from 0.65 V to 3.3 V. An RF energy harvester is also designed to charge the battery during the working mode or standby mode of the node. The power consumption of the proposed node reaches 14 mW in working mode to prolong the battery lifetime. The software is supported by the nesC language under the TinyOS environment, which enables the proposed node to be easily configured to function as an individual health monitoring node or a node in a wireless body sensor network (BSN). The proposed node is used to set up a wireless BSN that can simultaneously collect ECG and PPG signals and monitor the results on the personal computer.

  10. Using cardiovascular imaging modalities to determine cardiac disorders before starting sports activities.

    PubMed

    Ceylan, Özgür; Meşe, Timur; Gürsu, Alper Hazım

    2017-03-01

    We re-examined children who had previously been declared eligible to participate in competitive sports activities for cardiac disorders, using cardiac investigation protocol. Total of 250 children (224 males [89.6%], and 26 females [10.4%]) between the ages of 8 and 17 years who had just started or were already engaged in sports activities were included in the study. Participants had detailed physical examination evaluated by a pediatric cardiologist. Those with findings suggesting cardiac disorder in their history and/or physical examinations, and/or 12-channel electrocardiography (ECG) were examined with echocardiography (ECHO), 24-hour Holter monitoring, and exercise test. Mean duration of participation in sports activities was 13 months. Among all, 10.4% of the children had abnormalities on ECG. ECHO demonstrated cardiomyopathy in 1, mitral valve prolapse in 2, tricuspid insufficiency in 2, and mitral insufficiency in 1 participant. Holter monitoring revealed non-sustained ventricular tachycardia attacks in 1, and supraventricular tachycardia in another child. Three were ultimately disqualified from partaking in competitive sports. Sports and medical communities must work together to establish study protocols to prevent sudden death related to sports and to make these activities safer for athletes. Pediatric cardiology consultation for young athletes before they start sports activities is needed.

  11. Development and investigation of the nanosensor-based apparatus to assess the psycho-emotional state of a person

    NASA Astrophysics Data System (ADS)

    Avdeeva, D. K.; Ivanov, M. L.; Natalinova, N. M.; Nguyen, D. K.; Rybalka, S. A.; Turushev, N. V.

    2017-08-01

    Psycho-emotional state is one of the factors effecting human health. Its evaluation allows revealing hidden psychological trauma which can be reason of chronic stress, depression or psychosomatic disorders. Modern techniques of objective psycho-emotional state assessment involve a device which detects electrophysiological parameters of human body connected with emotional reaction and psychological condition. The present study covers development and testing of psycho-emotional state assessment device. The developed implement uses three methods of electrophysiological activity evaluation: electrocardiography, electroencephalography and galvanic skin response detection. The device represents hardware-software complex consisting of nanosensors, measuring unit, lead wires and laptop. Filters are excluded from the measuring circuit due to metrological parameters and noise immunity of implemented nanosensors. This solution minimizes signal distortion and allows measuring signals of 0.3 μV and higher in a wide frequency range (0-10000 Hz) with minimal data loss. In addition, results of preliminary medical studies aimed to find correspondence between different psycho-emotional states and electrophysiological parameters are described. Impact of filters on electrophysiological studies was studied. According to the results conventional filters significantly distort EEG channel information. Further research will be directed to the creation of complete base of electrophysiological parameters related to a particular emotion.

  12. Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method

    PubMed Central

    Chen, Keyun; Ren, Lei; Chen, Zhipeng; Pan, Chengfeng; Zhou, Wei; Jiang, Lelun

    2016-01-01

    Micro-needle electrodes (MEs) have attracted more and more attention for monitoring physiological electrical signals, including electrode-skin interface impedance (EII), electromyography (EMG) and electrocardiography (ECG) recording. A magnetization-induced self-assembling method (MSM) was developed to fabricate a microneedle array (MA). A MA coated with Ti/Au film was assembled as a ME. The fracture and insertion properties of ME were tested by experiments. The bio-signal recording performance of the ME was measured and compared with a typical commercial wet electrode (Ag/AgCl electrode). The results show that the MA self-assembled from the magnetic droplet array under the sum of gravitational surface tension and magnetic potential energies. The ME had good toughness and could easily pierce rabbit skin without being broken or buckling. When the compression force applied on the ME was larger than 2 N, ME could stably record EII, which was a lower value than that measured by Ag/AgCl electrodes. EMG signals collected by ME varied along with the contraction of biceps brachii muscle. ME could record static ECG signals with a larger amplitude and dynamic ECG signals with more distinguishable features in comparison with a Ag/AgCl electrode, therefore, ME is an alternative electrode for bio-signal monitoring in some specific situations. PMID:27657072

  13. Relationship between sleep stages and nocturnal trapezius muscle activity.

    PubMed

    Müller, Christian; Nicoletti, Corinne; Omlin, Sarah; Brink, Mark; Läubli, Thomas

    2015-06-01

    Former studies reported a relationship between increased nocturnal low level trapezius muscle activity and neck or shoulder pain but it has not been explored whether trapezius muscle relaxation is related to sleep stages. The goal of the present study was to investigate whether trapezius muscle activity is related to different sleep stages, as measured by polysomnography. Twenty one healthy subjects were measured on four consecutive nights in their homes, whereas the first night served as adaptation night. The measurements included full polysomnography (electroencephalography (EEG), electrooculography (EOG), electromyography (EMG) and electrocardiography (ECG)), as well as surface EMG of the m. trapezius descendens of the dominant arm. Periods with detectable EMG activity of the trapezius muscle lasted on average 1.5% of the length of the nights and only in four nights it lasted longer than 5% of sleeping time. Neither rest time nor the length of periods with higher activity levels of the trapezius muscle did significantly differ between sleep stages. We found no evidence that nocturnal trapezius muscle activity is markedly moderated by the different sleep stages. Thus the results support that EMG measurements of trapezius muscle activity in healthy subjects can be carried out without concurrent polysomnographic recordings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Automatic detection of respiration rate from ambulatory single-lead ECG.

    PubMed

    Boyle, Justin; Bidargaddi, Niranjan; Sarela, Antti; Karunanithi, Mohan

    2009-11-01

    Ambulatory electrocardiography is increasingly being used in clinical practice to detect abnormal electrical behavior of the heart during ordinary daily activities. The utility of this monitoring can be improved by deriving respiration, which previously has been based on overnight apnea studies where patients are stationary, or the use of multilead ECG systems for stress testing. We compared six respiratory measures derived from a single-lead portable ECG monitor with simultaneously measured respiration air flow obtained from an ambulatory nasal cannula respiratory monitor. Ten controlled 1-h recordings were performed covering activities of daily living (lying, sitting, standing, walking, jogging, running, and stair climbing) and six overnight studies. The best method was an average of a 0.2-0.8 Hz bandpass filter and RR technique based on lengthening and shortening of the RR interval. Mean error rates with the reference gold standard were +/-4 breaths per minute (bpm) (all activities), +/-2 bpm (lying and sitting), and +/-1 breath per minute (overnight studies). Statistically similar results were obtained using heart rate information alone (RR technique) compared to the best technique derived from the full ECG waveform that simplifies data collection procedures. The study shows that respiration can be derived under dynamic activities from a single-lead ECG without significant differences from traditional methods.

  15. Cardiorespiratory alterations in rodents experimentally envenomed with Hadruroides lunatus scorpion venom.

    PubMed

    Costal-Oliveira, Fernanda; Guerra-Duarte, Clara; Oliveira, Maira Souza; Castro, Karen Larissa Pereira de; Lopes-de-Sousa, Leticia; Lara, Aline; Gomes, Enéas Ricardo de Morais; Bonilla, Cesar; Guatimosim, Sílvia; Melo, Marília Martins; Chávez-Olórtegui, Carlos

    2017-01-01

    Hadruroides lunatus is the most abundant scorpion species in the Peruvian central coast, where most of the accidents involving humans are registered. In spite of its prevalence, there are only very few studies on H. lunatus envenomation. The aim of the present study was to analyze the cardiorespiratory alterations caused by H. lunatus envenomation in rodents. Wistar rats injected with H. lunatus scorpion venom were submitted to electrocardiography. After euthanasia, rat lungs were collected and histopathologically analyzed. Mouse cardiomyocytes were used to perform immunofluorescence and calcium transient assays. Data were analyzed by ANOVA or Student's t-test. The significance level was set at p < 0.05. It was observed that H. lunatus venom increased heart rate and caused arrhythmia, thereby impairing the heart functioning. Lungs of envenomed animals showed significant alterations, such as diffuse hemorrhage. In addition, immunofluorescence showed that H. lunatus venom was capable of binding to cardiomyocytes. Furthermore, mouse ventricular cardiomyocytes incubated with H. lunatus venom showed a significant decrease in calcium transient, confirming that H. lunatus venom exerts a toxic effect on heart. Our results showed that H. lunatus venom is capable of inducing cardiorespiratory alterations, a typical systemic effect of scorpionism, stressing the importance of medical monitoring in envenomation cases.

  16. Safe adalimumab therapy for rheumatoid arthritis in a patient with pre-existing multiple myeloma.

    PubMed

    Mielke, Frank; Schweigert, Marcus

    2008-04-01

    We report on a patient with rheumatoid arthritis (RA) who was treated with adalimumab and retrospectively diagnosed as having a multiple myeloma. In addition to the determination of clinical symptoms, investigations included radiography of the thorax, spine, hands and feet, arthrosonography, determination of laboratory parameters (including C-reactive protein levels and presence of antibodies against cyclic citrullinated peptide), cytogenetics and electrocardiography. RA was initially diagnosed in 1988. Stage II and stage III RA were diagnosed for the left and right foot, respectively, in 1996. Joints of both hands were diagnosed with stage I RA; both wrists and some finger joints showed signs of synovitis. Plasmocytoma was diagnosed in 2004; however, investigation of medical records revealed evidence of multiple myeloma 8 years earlier, in 1996. RA was originally treated with gold, sulfasalazine, azathioprin and glucocorticoid. Methotrexate was later used in addition to cortisone and then in combination with a selective cyclo-oxygenase-2 inhibitor. A combination therapy consisting of adalimumab (40 mg every 2 weeks), methotrexate (15 mg weekly) and a cyclo-oxygenase-2 inhibitor (rofecoxib 25 mg daily until July 2004, etoricoxib 90 mg daily from October 2004) was started in November 2003. Adalimumab therapy was interrupted for 6 months owing to safety concerns, but was resumed after a careful risk-benefit assessment.

  17. Detection of Cardiac Quiescence from B-Mode Echocardiography Using a Correlation-Based Frame-to-Frame Deviation Measure

    PubMed Central

    Mcclellan, James H.; Ravichandran, Lakshminarayan; Tridandapani, Srini

    2013-01-01

    Two novel methods for detecting cardiac quiescent phases from B-mode echocardiography using a correlation-based frame-to-frame deviation measure were developed. Accurate knowledge of cardiac quiescence is crucial to the performance of many imaging modalities, including computed tomography coronary angiography (CTCA). Synchronous electrocardiography (ECG) and echocardiography data were obtained from 10 healthy human subjects (four male, six female, 23–45 years) and the interventricular septum (IVS) was observed using the apical four-chamber echocardiographic view. The velocity of the IVS was derived from active contour tracking and verified using tissue Doppler imaging echocardiography methods. In turn, the frame-to-frame deviation methods for identifying quiescence of the IVS were verified using active contour tracking. The timing of the diastolic quiescent phase was found to exhibit both inter- and intra-subject variability, suggesting that the current method of CTCA gating based on the ECG is suboptimal and that gating based on signals derived from cardiac motion are likely more accurate in predicting quiescence for cardiac imaging. Two robust and efficient methods for identifying cardiac quiescent phases from B-mode echocardiographic data were developed and verified. The methods presented in this paper will be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality. PMID:26609501

  18. Providing Telehealth Services to a Public Primary Care Network: The Experience of RedeNUTES in Pernambuco, Brazil.

    PubMed

    Diniz, Paula Rejane Beserra; Ribeiro Sales, Fernando José; de Araújo Novaes, Magdala

    2016-08-01

    Information technologies have been applied in primary care domains to improve the delivery of health services. This article reports the telehealth network experience in Pernambuco, Brazil. Five different data sets were used, one by each service and the structural aspects of the network, collected from 2008 until August 2015. The data include solicited themes for educational activities, users' evaluation of services, numbers of sites, municipalities participating, participants in tele-education activities, teleconsultations, telediagnosis, and remote screenings. The analysis was done in absolute and percentage values using Microsoft Excel (version 2007). The indicators show high utilization of tele-education resources, followed by the teleconsultation service. The synchronous modality was the most used and the general clinical question was the most frequent type of question. Nurses are the professional category that most used the teleconsultation services (36%). Telediagnosis of electrocardiography has growth utilization, overcoming teleconsulting more recently. The satisfaction rate was 89%, and 68.5% of professionals changed their planning to patients' referrals to specialists. Telehealth has been considered effective since it avoids inappropriate referrals of the patient and provides continuous actualization to health professionals. Our results provide evidence of the feasibility and importance of using telehealth as a tool to ensure the universality, equality, and completeness in the health system.

  19. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition

    PubMed Central

    Fong, Ee-May; Chung, Wan-Young

    2015-01-01

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject’s skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3–15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio. PMID:26251913

  20. Automated Detection of Atrial Fibrillation Based on Time-Frequency Analysis of Seismocardiograms.

    PubMed

    Hurnanen, Tero; Lehtonen, Eero; Tadi, Mojtaba Jafari; Kuusela, Tom; Kiviniemi, Tuomas; Saraste, Antti; Vasankari, Tuija; Airaksinen, Juhani; Koivisto, Tero; Pankaala, Mikko

    2017-09-01

    In this paper, a novel method to detect atrial fibrillation (AFib) from a seismocardiogram (SCG) is presented. The proposed method is based on linear classification of the spectral entropy and a heart rate variability index computed from the SCG. The performance of the developed algorithm is demonstrated on data gathered from 13 patients in clinical setting. After motion artifact removal, in total 119 min of AFib data and 126 min of sinus rhythm data were considered for automated AFib detection. No other arrhythmias were considered in this study. The proposed algorithm requires no direct heartbeat peak detection from the SCG data, which makes it tolerant against interpersonal variations in the SCG morphology, and noise. Furthermore, the proposed method relies solely on the SCG and needs no complementary electrocardiography to be functional. For the considered data, the detection method performs well even on relatively low quality SCG signals. Using a majority voting scheme that takes five randomly selected segments from a signal and classifies these segments using the proposed algorithm, we obtained an average true positive rate of [Formula: see text] and an average true negative rate of [Formula: see text] for detecting AFib in leave-one-out cross-validation. This paper facilitates adoption of microelectromechanical sensor based heart monitoring devices for arrhythmia detection.

  1. A new algorithm for segmentation of cardiac quiescent phases and cardiac time intervals using seismocardiography

    NASA Astrophysics Data System (ADS)

    Jafari Tadi, Mojtaba; Koivisto, Tero; Pänkäälä, Mikko; Paasio, Ari; Knuutila, Timo; Teräs, Mika; Hänninen, Pekka

    2015-03-01

    Systolic time intervals (STI) have significant diagnostic values for a clinical assessment of the left ventricle in adults. This study was conducted to explore the feasibility of using seismocardiography (SCG) to measure the systolic timings of the cardiac cycle accurately. An algorithm was developed for the automatic localization of the cardiac events (e.g. the opening and closing moments of the aortic and mitral valves). Synchronously acquired SCG and electrocardiography (ECG) enabled an accurate beat to beat estimation of the electromechanical systole (QS2), pre-ejection period (PEP) index and left ventricular ejection time (LVET) index. The performance of the algorithm was evaluated on a healthy test group with no evidence of cardiovascular disease (CVD). STI values were corrected based on Weissler's regression method in order to assess the correlation between the heart rate and STIs. One can see from the results that STIs correlate poorly with the heart rate (HR) on this test group. An algorithm was developed to visualize the quiescent phases of the cardiac cycle. A color map displaying the magnitude of SCG accelerations for multiple heartbeats visualizes the average cardiac motions and thereby helps to identify quiescent phases. High correlation between the heart rate and the duration of the cardiac quiescent phases was observed.

  2. Lighting to Make You Feel Better: Improving the Mood of Elderly People with Affective Ambiences

    PubMed Central

    Kuijsters, Andre; Redi, Judith; de Ruyter, Boris; Heynderickx, Ingrid

    2015-01-01

    Current lighting technologies extend the options for changing the appearance of rooms and closed spaces, as such creating ambiences with an affective meaning. Using intelligence, these ambiences may instantly be adapted to the needs of the room’s occupant(s), possibly improving their well-being. We hypothesized that ambiences with a clearly recognizable, positive affective meaning could be used to effectively mitigate negative mood in elderly. After inducing a sad mood with a short movie one group of elderly was immersed in a positive high arousing (i.e., activating) ambience, and another group in a neutral ambience. Similarly, after inducing anxiety with a short movie one group of elderly was immersed in a pleasant low arousing (i.e., cozy) ambience, and another group in a neutral ambience. We monitored the evolution of the mood of the four groups of elderly over a period of ten minutes after the mood induction, with both self-reported mood measurements (every 2 minutes) and constant measurements of the skin conductance response (SCR) and electrocardiography (ECG). In line with our hypothesis we found that the activating ambience was physiologically more arousing than the neutral ambience. The cozy ambience was more effective in calming anxious elderly than the neutral ambience, as reflected by both the self-reported and physiological measurements. PMID:26192281

  3. The Effect of Heart Rate on Exposure Window and Best Phase for Stress Perfusion Computed Tomography: Lessons From the CORE320 Study.

    PubMed

    Steveson, Chloe; Schuijf, Joanne D; Vavere, Andrea L; Mather, Richard T; Caton, Teresa; Mehra, Vishal; Betoko, Aisha; Cox, Christopher; Lima, Joao Ac; George, Richard T

    The aim of this study is to evaluate the effect of heart rate on exposure window, best phase, and image quality for stress computed tomography perfusion (CTP) in the CORE320 study. The CTP data sets were analyzed to determine the best phase for perfusion analysis. A predefined exposure window covering 75% to 95% of the R-R cycle was used. Of the 368 patients included in the analysis, 93% received oral β blockade before the rest scan. The median heart rate during the stress acquisition was 69 bpm (interquartile range [IQR], 60-77). The median best phase was 81% (IQR, 76-90), and length of exposure window was 22% (IQR, 19-24). The best phase was significantly later in the cardiac cycle with higher heart rates (P < 0.001), and higher heart rates resulted in a small, but higher number of poor quality scans (6%, P < 0.001). The median effective dose of the stress scan was 5.3 mSv (IQR, 3.8-6.1). Stress myocardial CTP imaging can be performed using prospective electrocardiography triggering, an exposure window of 75% to 95%, and β-blockade resulting in good or excellent image quality in the majority (80%) of patients while maintaining a low effective radiation dose.

  4. Specificity of autonomic arousal to anxiety in children with autism spectrum disorder.

    PubMed

    Chiu, Tabitha A; Anagnostou, Evdokia; Brian, Jessica; Chau, Tom; Kushki, Azadeh

    2016-04-01

    Anxiety is one of the most concerning comorbidities in autism spectrum disorder (ASD) due to its high prevalence, negative impact on physical and psychological well-being, and interaction with core deficits of ASD. Current assessment and treatment of anxiety, which rely on the observation of behavior and self-reports, are often ineffective as ASD is associated with deficits in communication and diminished introspective ability. In this light, autonomic nervous system (ANS) activity has been suggested as a marker of physiological arousal associated with anxiety. However, physiological arousal measured by ANS indices also occurs with other cognitive and emotional processes, and it is unclear whether anxiety-related arousal can be differentiated from that related to other cognitive processes. To address this gap, we investigated the use of linear and nonlinear classification techniques for differentiating anxiety-related arousal from arousal due to three cognitive processes (attention, inhibitory control, and social cognition) and physical activity based on electrocardiography signal features. Our results indicate that over 80% classification accuracy can be achieved, suggesting that ANS response can be used as a specific marker of anxiety-related arousal in a subgroup of children with ASD who demonstrate an increase in heart rate in response to anxiogenic stimuli. © 2015 International Society for Autism Research, Wiley Periodicals, Inc.

  5. Twelve-lead electrocardiography in the young: physiologic and pathologic abnormalities.

    PubMed

    Kobza, Richard; Cuculi, Florim; Abächerli, Roger; Toggweiler, Stefan; Suter, Yves; Frey, Franz; Schmid, Johann Jakob; Erne, Paul

    2012-12-01

    BACKGROUND/ OBJECTIVE: The purpose of the present study was to analyze the prevalence of physiologic and pathologic ECG abnormalities in a cohort of young conscripts that represents the whole young generation of today. ECGs of all Swiss citizens who underwent conscription for the army during a 29-month period were analyzed manually. ECGs of 43,401 conscripts (mean age 19.2 ± 1.1 years) were analyzed; 158 conscripts were female. Incomplete right bundle branch block was found in 5870 (13.5%) and left anterior fascicular block in 360 (0.83%). First-degree AV block was present in 329 (0.8%) and Mobitz type I (Wenckebach) second-degree AV block in 3 (0.01%). Early repolarization was observed in 1035 (2.4%), T-wave inversion in 39 (0.09%), and minor T-wave changes in 182 (0.42%). Brugada-like abnormalities were observed in 6 (0.01%). None of the conscripts had atrial fibrillation or flutter. ECG abnormalities can be found in a relatively large proportion of young individuals. Incomplete right bundle branch block, left fascicular block, and first-degree AV block are the most frequent findings. No conscript presented with atrial fibrillation or flutter. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Cardiopulmonary fitness and muscle strength in patients with osteogenesis imperfecta type I.

    PubMed

    Takken, Tim; Terlingen, Heike C; Helders, Paul J M; Pruijs, Hans; Van der Ent, Cornelis K; Engelbert, Raoul H H

    2004-12-01

    To evaluate cardiopulmonary function, muscle strength, and cardiopulmonary fitness (VO 2 peak) in patients with osteogenesis imperfecta (OI). In 17 patients with OI type I (mean age 13.3 +/- 3.9 years) cardiopulmonary function was assessed at rest using spirometry, plethysmography, electrocardiography, and echocardiography. Exercise capacity was measured using a maximal exercise test on a bicycle ergometer and an expired gas analysis system. Muscle strength in shoulder abductors, hip flexors, ankle dorsal flexor, and grip strength were measured. All results were compared with reference values. Cardiopulmonary function at rest was within normal ranges, but when it was compared with normal height for age and sex, vital capacities were reduced. Mean absolute and relative VO 2 peak were respectively -1.17 (+/- 0.67) and -1.41 (+/- 1.52) standard deviations lower compared with reference values ( P < .01). Muscle strength also was significantly reduced in patients with OI, ranging from -1.24 +/- 1.40 to -2.88 +/- 2.67 standard deviations lower compared with reference values. In patients with OI type I, no pulmonary or cardiac abnormalities at rest were found. The exercise tolerance and muscle strength were significantly reduced in patients with OI, which might account for their increased levels of fatigue during activities of daily living.

  7. Seismic data fusion anomaly detection

    NASA Astrophysics Data System (ADS)

    Harrity, Kyle; Blasch, Erik; Alford, Mark; Ezekiel, Soundararajan; Ferris, David

    2014-06-01

    Detecting anomalies in non-stationary signals has valuable applications in many fields including medicine and meteorology. These include uses such as identifying possible heart conditions from an Electrocardiography (ECG) signals or predicting earthquakes via seismographic data. Over the many choices of anomaly detection algorithms, it is important to compare possible methods. In this paper, we examine and compare two approaches to anomaly detection and see how data fusion methods may improve performance. The first approach involves using an artificial neural network (ANN) to detect anomalies in a wavelet de-noised signal. The other method uses a perspective neural network (PNN) to analyze an arbitrary number of "perspectives" or transformations of the observed signal for anomalies. Possible perspectives may include wavelet de-noising, Fourier transform, peak-filtering, etc.. In order to evaluate these techniques via signal fusion metrics, we must apply signal preprocessing techniques such as de-noising methods to the original signal and then use a neural network to find anomalies in the generated signal. From this secondary result it is possible to use data fusion techniques that can be evaluated via existing data fusion metrics for single and multiple perspectives. The result will show which anomaly detection method, according to the metrics, is better suited overall for anomaly detection applications. The method used in this study could be applied to compare other signal processing algorithms.

  8. Delay Differential Equation Models of Normal and Diseased Electrocardiograms

    NASA Astrophysics Data System (ADS)

    Lainscsek, Claudia; Sejnowski, Terrence J.

    Time series analysis with nonlinear delay differential equations (DDEs) is a powerful tool since it reveals spectral as well as nonlinear properties of the underlying dynamical system. Here global DDE models are used to analyze electrocardiography recordings (ECGs) in order to capture distinguishing features for different heart conditions such as normal heart beat, congestive heart failure, and atrial fibrillation. To capture distinguishing features of the different data types the number of terms and delays in the model as well as the order of nonlinearity of the DDE model have to be selected. The DDE structure selection is done in a supervised way by selecting the DDE that best separates different data types. We analyzed 24 h of data from 15 young healthy subjects in normal sinus rhythm (NSR) of 15 congestive heart failure (CHF) patients as well as of 15 subjects suffering from atrial fibrillation (AF) selected from the Physionet database. For the analysis presented here we used 5 min non-overlapping data windows on the raw data without any artifact removal. For classification performance we used the Cohen Kappa coefficient computed directly from the confusion matrix. The overall classification performance of the three groups was around 72-99 % on the 5 min windows for the different approaches. For 2 h data windows the classification for all three groups was above 95%.

  9. An innovative nonintrusive driver assistance system for vital signal monitoring.

    PubMed

    Sun, Ye; Yu, Xiong Bill

    2014-11-01

    This paper describes an in-vehicle nonintrusive biopotential measurement system for driver health monitoring and fatigue detection. Previous research has found that the physiological signals including eye features, electrocardiography (ECG), electroencephalography (EEG) and their secondary parameters such as heart rate and HR variability are good indicators of health state as well as driver fatigue. A conventional biopotential measurement system requires the electrodes to be in contact with human body. This not only interferes with the driver operation, but also is not feasible for long-term monitoring purpose. The driver assistance system in this paper can remotely detect the biopotential signals with no physical contact with human skin. With delicate sensor and electronic design, ECG, EEG, and eye blinking can be measured. Experiments were conducted on a high fidelity driving simulator to validate the system performance. The system was found to be able to detect the ECG/EEG signals through cloth or hair with no contact with skin. Eye blinking activities can also be detected at a distance of 10 cm. Digital signal processing algorithms were developed to decimate the signal noise and extract the physiological features. The extracted features from the vital signals were further analyzed to assess the potential criterion for alertness and drowsiness determination.

  10. Electrocardiogram of Clinically Healthy Mithun (Bos frontalis): Variation among Strains

    PubMed Central

    Sanyal, Sagar; Das, Pradip Kumar; Ghosh, Probal Ranjan; Das, Kinsuk; Vupru, Kezha V.; Rajkhowa, Chandan; Mondal, Mohan

    2010-01-01

    A study was conducted to establish the normal electrocardiogram in four different genetic strains of mithun (Bos frontalis). Electrocardiography, cardiac electrical axis, heart rate, rectal temperature and respiration rate were recorded in a total of 32 adult male mithun of four strains (n = 8 each). It was found that the respiration and heart rates were higher (P < .05) in Manipur than other three strains. Amplitude (P < .05) and duration of P wave and QRS complex differed (P < .01) among the strains. Mizoram strain had the highest amplitude and duration of P wave and QRS complex. On the other hand, higher (P < .05) amplitude and duration of T wave were recorded in Arunachalee and Mizoram strains. The mean electrical axis of QRS complex that were recorded for Arunachalee and Manipur strains were similar to that reported for other bovine species; whereas the electrical axis of QRS for Nagamese and Mizoram strains were more close to feline and caprine species, respectively. In conclusion, electrocardiogram of mithun revealed that the amplitude and duration of P wave, QRS complex and T wave were different among four different genetic strains of mithun and the electrical axis of QRS complex for Nagamese and Mizoram mithuns are dissimilar to bovine species. PMID:20886013

  11. Development and significance of a fetal electrocardiogram recorded by signal-averaged high-amplification electrocardiography.

    PubMed

    Hayashi, Risa; Nakai, Kenji; Fukushima, Akimune; Itoh, Manabu; Sugiyama, Toru

    2009-03-01

    Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.

  12. Anti-voltage-gated potassium channel Kv1.4 antibodies in myasthenia gravis.

    PubMed

    Romi, Fredrik; Suzuki, Shigeaki; Suzuki, Norihiro; Petzold, Axel; Plant, Gordon T; Gilhus, Nils Erik

    2012-07-01

    Myasthenia gravis (MG) is an autoimmune disease characterized by skeletal muscle weakness mainly caused by acetylcholine receptor antibodies. MG can be divided into generalized and ocular, and into early-onset (<50 years of age) and late-onset (≥50 years of age). Anti-Kv1.4 antibodies targeting α-subunits (Kv1.4) of the voltage-gated potassium K(+) channel occurs frequently among patients with severe MG, accounting for 18% of a Japanese MG population. The aim of this study was to characterize the clinical features and serological associations of anti-Kv1.4 antibodies in a Caucasian MG population with mild and localized MG. Serum samples from 129 Caucasian MG patients with mainly ocular symptoms were tested for the presence of anti-Kv1.4 antibodies and compared to clinical and serological parameters. There were 22 (17%) anti-Kv1.4 antibody-positive patients, most of them women with late-onset MG, and all of them with mild MG. This contrasts to the Japanese anti-Kv1.4 antibody-positive patients who suffered from severe MG with bulbar symptoms, myasthenic crisis, thymoma, myocarditis and prolonged QT time on electrocardiography, despite equal anti-Kv1.4 antibody occurrence in both populations. No other clinical or serological parameters influenced anti-Kv1.4 antibody occurrence.

  13. A general framework for time series data mining based on event analysis: application to the medical domains of electroencephalography and stabilometry.

    PubMed

    Lara, Juan A; Lizcano, David; Pérez, Aurora; Valente, Juan P

    2014-10-01

    There are now domains where information is recorded over a period of time, leading to sequences of data known as time series. In many domains, like medicine, time series analysis requires to focus on certain regions of interest, known as events, rather than analyzing the whole time series. In this paper, we propose a framework for knowledge discovery in both one-dimensional and multidimensional time series containing events. We show how our approach can be used to classify medical time series by means of a process that identifies events in time series, generates time series reference models of representative events and compares two time series by analyzing the events they have in common. We have applied our framework on time series generated in the areas of electroencephalography (EEG) and stabilometry. Framework performance was evaluated in terms of classification accuracy, and the results confirmed that the proposed schema has potential for classifying EEG and stabilometric signals. The proposed framework is useful for discovering knowledge from medical time series containing events, such as stabilometric and electroencephalographic time series. These results would be equally applicable to other medical domains generating iconographic time series, such as, for example, electrocardiography (ECG). Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Atrial Electromechanical Coupling in Patients with Lichen Planus

    PubMed Central

    Yaman, Mehmet; Beton, Osman; Asarcıklı, Lale Dinç; Aksakal, Aytekin; Dogdu, Orhan

    2016-01-01

    Background and objectives A chronic inflammatory disease, lichen planus may cause disturbance of atrial electromechanical coupling and increase the risk of atrial fibrillation. The aim of this study was to evaluate atrial electromechanical delay with both electrocardiography (ECG) and echocardiography in patients with lichen planus (LP). Subjects and Methods Seventy-two LP patients (43 males [59.7%], mean age: 44.0±16.7 years) were enrolled in this cross-sectional case-control study. The control group was selected in a 1:1 ratio from 70 patients in an age and sex matched manner. P wave dispersion was measured by ECG to show atrial electromechanical delay. All of the patients underwent transthoracic echocardiography for measuring inter- and intra-atrial electromechanical delays. Results The baseline characteristics of the patients and the control group were similar except for the presence of LP. P-wave dispersion measured by ECG was significantly higher in patients with LP (p<0.001). Patients with LP had significantly prolonged intra- and interatrial electromechanical delays when compared to the control group (p<0.001). In addition, all of these variables were significantly correlated with high sensitive C-reactive protein (hsCRP) levels. Conclusion Atrial electromechanical coupling, which is significantly correlated with increased hsCRP levels, is impaired in patients with LP. PMID:27482262

  15. Wireless sensor and data transmission needs and technologies for patient monitoring in the operating room and intensive care unit.

    PubMed

    Paksuniemi, M; Sorvoja, H; Alasaarela, E; Myllyla, R

    2005-01-01

    In the intensive care unit, or during anesthesia, patients are attached to monitors by cables. These cables obstruct nursing staff and hinder the patients from moving freely in the hospital. However, rapidly developing wireless technologies are expected to solve these problems. To this end, this study revealed problem areas in current patient monitoring and established the most important medical parameters to monitor. In addition, usable wireless techniques for short-range data transmission were explored and currently employed wireless applications in the hospital environment were studied. The most important parameters measured of the patient include blood pressures, electrocardiography, respiration rate, heart rate and temperature. Currently used wireless techniques in hospitals are based on the WMTS and WLAN standards. There are no viable solutions for short-range data transmission from patient sensors to patient monitors, but potentially usable techniques in the future are based on the WPAN standards. These techniques include Bluetooth, ZigBee and UWB. Other suitable techniques might be based on capacitive or inductive coupling. The establishing of wireless techniques depends on ensuring the reliability of data transmission, eliminating disturbance by other wireless devices, ensuring patient data security and patient safety, and lowering the power consumption and price.

  16. Physiological effects of railway vibration and noise on sleep

    PubMed Central

    Smith, Michael G.; Croy, Ilona; Ögren, Mikael; Hammar, Oscar; Lindberg, Eva; Persson Waye, Kerstin

    2017-01-01

    This paper evaluates the relative contribution of vibration and noise from railway on physiological sleep outcomes. Vibration from railway freight often accompanies airborne noise, yet is almost totally absent in the existing literature. In an experimental investigation, 23 participants, each sleeping for six nights in the laboratory, were exposed to 36 simulated railway freight pass-bys per night with vibration alone (aWd,max = 0.0204 ms−2), noise alone (LAF,max = 49.8 dB), or both vibration and noise simultaneously. A fourth exposure night involved 52 pass-bys with concurrent vibration and noise. Sleep was measured with polysomnography. Cardiac activity was measured with electrocardiography. The probability of cortical arousals or awakenings was greater following all exposures, including vibration alone, than spontaneous reaction probability (p < 0.05). The effects of vibration exposure and noise exposure on changes of sleep stage and arousals were directly additive. Vibration and noise exposure both induced heart rate acceleration above spontaneously expected fluctuations at baseline. The results indicate that vibration and noise are processed in the brain separately yet in parallel, with both contributing towards the likelihood of sleep disruption. The findings show that vibration is of importance when considering the impact of railway freight on sleep. PMID:28599531

  17. Investigation of visually induced motion sickness in dynamic 3D contents based on subjective judgment, heart rate variability, and depth gaze behavior.

    PubMed

    Wibirama, Sunu; Hamamoto, Kazuhiko

    2014-01-01

    Visually induced motion sickness (VIMS) is an important safety issue in stereoscopic 3D technology. Accompanying subjective judgment of VIMS with objective measurement is useful to identify not only biomedical effects of dynamic 3D contents, but also provoking scenes that induce VIMS, duration of VIMS, and user behavior during VIMS. Heart rate variability and depth gaze behavior are appropriate physiological indicators for such objective observation. However, there is no information about relationship between subjective judgment of VIMS, heart rate variability, and depth gaze behavior. In this paper, we present a novel investigation of VIMS based on simulator sickness questionnaire (SSQ), electrocardiography (ECG), and 3D gaze tracking. Statistical analysis on SSQ data shows that nausea and disorientation symptoms increase as amount of dynamic motions increases (nausea: p<;0.005; disorientation: p<;0.05). To reduce VIMS, SSQ and ECG data suggest that user should perform voluntary gaze fixation at one point when experiencing vertical motion (up or down) and horizontal motion (turn left and right) in dynamic 3D contents. Observation of 3D gaze tracking data reveals that users who experienced VIMS tended to have unstable depth gaze than ones who did not experience VIMS.

  18. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

    PubMed

    Fong, Ee-May; Chung, Wan-Young

    2015-08-05

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.

  19. Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring.

    PubMed

    Hoog Antink, Christoph; Schulz, Florian; Leonhardt, Steffen; Walter, Marian

    2017-12-25

    Sensors integrated into objects of everyday life potentially allow unobtrusive health monitoring at home. However, since the coupling of sensors and subject is not as well-defined as compared to a clinical setting, the signal quality is much more variable and can be disturbed significantly by motion artifacts. One way of tackling this challenge is the combined evaluation of multiple channels via sensor fusion. For robust and accurate sensor fusion, analyzing the influence of motion on different modalities is crucial. In this work, a multimodal sensor setup integrated into an armchair is presented that combines capacitively coupled electrocardiography, reflective photoplethysmography, two high-frequency impedance sensors and two types of ballistocardiography sensors. To quantify motion artifacts, a motion protocol performed by healthy volunteers is recorded with a motion capture system, and reference sensors perform cardiorespiratory monitoring. The shape-based signal-to-noise ratio SNR S is introduced and used to quantify the effect on motion on different sensing modalities. Based on this analysis, an optimal combination of sensors and fusion methodology is developed and evaluated. Using the proposed approach, beat-to-beat heart-rate is estimated with a coverage of 99.5% and a mean absolute error of 7.9 ms on 425 min of data from seven volunteers in a proof-of-concept measurement scenario.

  20. Health hazards and mitigation of chronic poisoning from arsenic in drinking water: Taiwan experiences.

    PubMed

    Chen, Chien-Jen

    2014-01-01

    There are two endemic areas of long-term exposure to arsenic from drinking water in Taiwan. Residents in the southwestern and northeastern endemic areas started using high-arsenic artesian well water in the early 1910s and late 1940s, respectively. Public water supply system using surface water was implemented in southwestern and northeastern endemic areas in the 1970s and 1990s, respectively. Systemic health hazards of long-term exposure to arsenic in drinking water have been intensively investigated since the 1960s, especially after 1985 in Taiwan. Several diseases have been well documented to be associated with chronic arsenic poisoning from drinking water showing a dose-response relation. They include characteristic skin lesions like hyperpigmentation or depigmentation, hyperkeratosis in palms and soles, and Bowen disease, peripheral vascular disease (specifically blackfoot disease), ischemic heart disease, cerebral infarction, microvascular diseases, abnormal peripheral microcirculation, carotid atherosclerosis, QT prolongation and increased dispersion in electrocardiography, hypertension, goiter, diabetes mellitus, cataract (specifically posterior subcapsular lens opacity), pterygium, slow neural conduction, retarded neurobehavioral development, erectile dysfunction, and cancers of the skin, lung, urinary bladder, kidney, and liver. The method of choice to mitigate arsenic poisoning through drinking water is to use safe drinking water from uncontaminated sources.

  1. Effect of pacing-induced myocardial ischemia on platelet activation and fibrin formation in the coronary circulation.

    PubMed

    Nichols, A B; Gold, K D; Marcella, J J; Cannon, P J; Owen, J

    1987-07-01

    The effect of pacing-induced myocardial ischemia on platelet activation and fibrin formation was investigated in seven patients with severe proximal lesions of the left anterior descending coronary artery to determine if acute ischemia activates the coagulation system. Fibrin formation was assessed from plasma levels of fibrinopeptide A. Platelet activation was assessed by levels of platelet factor 4, beta-thromboglobulin and thromboxane B2. Plasma levels were measured before, during and after acute myocardial ischemia induced by rapid atrial pacing. Blood samples were collected from the ascending aorta and from the great cardiac vein through heparin-bonded catheters. The occurrence of anterior myocardial ischemia was established by electrocardiography and by myocardial lactate extraction. No significant transmyocardial gradients in the levels of fibrinopeptide A, platelet factor 4, beta-thromboglobulin or thromboxane B2 were found at rest, during ischemia or in the recovery period, and levels in the great cardiac vein did not change in response to ischemia. These data indicate that pacing-induced myocardial ischemia does not result in release of fibrinopeptide A, platelet factor 4, beta-thromboglobulin or thromboxane B2 into the coronary circulation, and imply that acute ischemia does not induce platelet activation or fibrin formation in the coronary circulation.

  2. Quantitative assessment of 12-lead ECG synthesis using CAVIAR.

    PubMed

    Scherer, J A; Rubel, P; Fayn, J; Willems, J L

    1992-01-01

    The objective of this study is to assess the performance of patient-specific segment-specific (PSSS) synthesis in QRST complexes using CAVIAR, a new method of the serial comparison for electrocardiograms and vectorcardiograms. A collection of 250 multi-lead recordings from the Common Standards for Quantitative Electrocardiography (CSE) diagnostic pilot study is employed. QRS and ST-T segments are independently synthesized using the PSSS algorithm so that the mean-squared error between the original and estimated waveforms is minimized. CAVIAR compares the recorded and synthesized QRS and ST-T segments and calculates the mean-quadratic deviation as a measure of error. The results of this study indicate that estimated QRS complexes are good representatives of their recorded counterparts, and the integrity of the spatial information is maintained by the PSSS synthesis process. Analysis of the ST-T segments suggests that the deviations between recorded and synthesized waveforms are considerably greater than those associated with the QRS complexes. The poorer performance of the ST-T segments is attributed to magnitude normalization of the spatial loops, low-voltage passages, and noise interference. Using the mean-quadratic deviation and CAVIAR as methods of performance assessment, this study indicates that the PSSS-synthesis algorithm accurately maintains the signal information within the 12-lead electrocardiogram.

  3. Reversion of left ventricular systolic dysfunction and abnormal stress test: by catheter ablation, in a patient with Wolff-Parkinson-White syndrome from Para-Hisian Kent bundle.

    PubMed

    Tu, Chung-Ming; Chu, Kai-Ming; Cheng, Cheng-Chung; Cheng, Shu-Mung; Lin, Wei-Shiang

    2010-01-01

    The diagnosis of Wolff-Parkinson-White syndrome is typically reserved for patients who experience ventricular pre-excitation and symptoms that are related to paroxysmal supraventricular tachycardia, such as chest pain, dyspnea, dizziness, palpitations, or syncope. Herein, we report the case of a 38-year-old woman who presented at our outpatient department because of exercise intolerance. Cardiac auscultation revealed a grade 2/6 pansystolic murmur over the left lower sternal border. Twelve-lead electrocardiography showed sinus rhythm at a rate of 76 beats/min, with a significant delta wave. Transthoracic echocardiography revealed abnormal left ventricular systolic function. The results of a thallium stress test were also abnormal. Coronary artery disease was suspected; however, coronary angiography yielded normal results. Electrophysiologic study revealed a para-Hisian Kent bundle and a dual atrioventricular nodal pathway. After radiofrequency catheter ablation was performed, the patient's left ventricular function improved and her symptoms disappeared. In Wolff-Parkinson-White syndrome, left ventricular systolic dyssynchrony can yield abnormal findings on echocardiography and thallium scanning--even in persons who have no cardiovascular risk factors. Physicians who are armed with this knowledge can avoid performing coronary angiography unnecessarily. Catheter ablation can reverse the dyssynchrony of the ventricle and improve the patient's symptoms.

  4. A young patient with atypical type-B Wolff–Parkinson–White syndrome accompanied by left ventricular dysfunction

    PubMed Central

    Takeuchi, Takahiro; Tomita, Takeshi; Kasai, Hiroki; Kashiwagi, Daisuke; Yoshie, Koji; Yaguchi, Tomonori; Oguchi, Yasutaka; Kozuka, Ayako; Gautam, Milan; Motoki, Hirohiko; Okada, Ayako; Shiba, Yuji; Aizawa, Kazunori; Izawa, Atsushi; Miyashita, Yusuke; Koyama, Jun; Hongo, Minoru; Ikeda, Uichi

    2014-01-01

    A 15-year-old asymptomatic male patient presented with an electrocardiographic abnormality and left ventricular (LV) dysfunction (left ventricle ejection fraction of 40%) in a physical examination performed 2 years previously. LV dysfunction did not improve despite optimal medical therapy for dilated cardiomyopathy. Twelve-lead electrocardiography revealed a normal PR interval (138 ms) with a small delta-like wave in V2, but not a typical diagnostic wave that could be diagnosed as Wolff–Parkinson–White (WPW) syndrome by an electrocardiogram auto-analysis. Transthoracic echocardiography showed a remarkable asynchronous septal motion. An electrophysiological study was performed to exclude WPW syndrome. An accessory pathway (AP) was revealed on the lateral wall of the right ventricle, and radiofrequency catheter ablation was successfully performed to disconnect the AP. Thereafter, the dyssynchrony disappeared, and LV function improved. The intrinsic atrioventricular nodal conduction was very slow (A-H, 237 ms). The results of electrocardiogram auto-analysis could not be used to confirm the diagnosis of WPW syndrome because of the atypical delta wave. Conduction via the right lateral AP caused electrical dyssynchrony in the LV. This case suggests that atypical delta waves should be evaluated without depending on electrocardiographic auto-analyses in patients with LV dysfunction accompanied by dyssynchrony. PMID:26336525

  5. Evaluation and management of pediatric hypertensive crises: hypertensive urgency and hypertensive emergencies

    PubMed Central

    Patel, Nirali H; Romero, Sarah K; Kaelber, David C

    2012-01-01

    Hypertension (HTN) in the pediatric population is estimated to have a world-wide prevalence of 2%–5%. As with adults, pediatric patients with HTN can present with hypertensive crises include hypertensive urgency and hypertensive emergencies. However, pediatric blood pressure problems have a greater chance of being from secondary causes of HTN, as opposed to primary HTN, than in adults. Thorough evaluation of a child with a hypertensive emergency includes accurate blood pressure readings, complete and focused symptom history, and appropriate past medical, surgical, and family history. Physical exam should include height, weight, four-limb blood pressures, a general overall examination and especially detailed cardiovascular and neurological examinations, including fundoscopic examination. Initial work-up should typically include electrocardiography, chest X-ray, serum chemistries, complete blood count, and urinalysis. Initial management of hypertensive emergencies generally includes the use of intravenous or oral antihypertensive medications, as well as appropriate, typically outpatient, follow-up. Emergency department goals for hypertensive crises are to (1) safely lower blood pressure, and (2) treat/minimize acute end organ damage, while (3) identifying underlying etiology. Intravenous antihypertensive medications are the treatment modality of choice for hypertensive emergencies with the goal of reducing systolic blood pressure by 25% of the original value over an 8-hour period. PMID:27147865

  6. Hybrid-Aware Model for Senior Wellness Service in Smart Home

    PubMed Central

    Jung, Yuchae

    2017-01-01

    Smart home technology with situation-awareness is important for seniors to improve safety and security. With the development of context-aware computing, wearable sensor technology, and ubiquitous computing, it is easier for seniors to manage their health problem in smart home environment. For monitoring senior activity in smart home, wearable, and motion sensors—such as respiration rate (RR), electrocardiography (ECG), body temperature, and blood pressure (BP)—were used for monitoring movements of seniors. For context-awareness, environmental sensors—such as gas, fire, smoke, dust, temperature, and light sensors—were used for senior location data collection. Based on senior activity, senior health status can be classified into positive and negative. Based on senior location and time, senior safety is classified into safe and emergency. In this paper, we propose a hybrid inspection service middleware for monitoring elderly health risk based on senior activity and location. This hybrid-aware model for the detection of abnormal status of seniors has four steps as follows: (1) data collection from biosensors and environmental sensors; (2) monitoring senior location and time of stay in each location using environmental sensors; (3) monitoring senior activity using biometric data; finally, (4) expectation-maximization based decision-making step recommending proper treatment based on a senior health risk ratio. PMID:28531157

  7. Zumba-induced Takotsubo cardiomyopathy: a case report.

    PubMed

    Chams, Sana; El Sayegh, Skye; Hamdon, Mulham; Kumar, Sarwan; Kulairi, Zain

    2018-06-10

    Takotsubo cardiomyopathy or stress cardiomyopathy is characterized by transient left ventricular apical ballooning in the absence of coronary occlusion. The underlying pathophysiological mechanism is still unclear but possible causes have been proposed mainly catecholamine cardiotoxicity, followed by metabolic disturbance, coronary microvascular impairment, and multivessel epicardial coronary artery vasospasm. Takotsubo cardiomyopathy accounts for 1-2% of patients presenting with acute coronary syndrome with the majority of patients diagnosed with Takotsubo cardiomyopathy being women > 55 years of age. Here, we discuss the case of a 38-year-old woman presenting with typical chest pain, electrocardiography changes and cardiac markers consistent with acute coronary syndrome, who was subsequently diagnosed with Takotsubo cardiomyopathy. A 38-year-old healthy American woman with negative past medical history presented to our Emergency Department with chest pain developing while participating in intense outdoor physical activities (Zumba) at a fundraising event. Our patient had typical substernal chest pain induced with exercise and was relieved by sublingual nitroglycerin in the Emergency Department. The pain started after 2 h of intensive Zumba workout. On review of her history, our patient was noted to be taking spironolactone 125 mg once daily for hirsutism for the past year. Our patient denied any family history of cardiac disease or heart failure. She admitted to being a former occasional smoker and to drinking alcohol socially. She denied any illicit drug use. She works as a social worker, and reported that she does not experience much stress in her life and denied any "one big life-changing event" or any major stressful news. While in the Emergency Department, our patient was hemodynamically stable and an electrocardiography was performed and showed sinus rhythm with no ST elevation/depression but noted T-wave inversion in leads I and aVL, and T wave flattening in leads V1 and V2. Her troponin levels were 0.294 and 0.231 consecutively. An echocardiogram was done and showed hypokinetic apical and mid-distal walls and hyperdynamic basal walls of the left ventricle with an ejection fraction of 35-40%, consistent with apical ballooning syndrome. Cardiac catheterization was subsequently done and showed depressed left ventricle systolic function, ejection fraction of 30-35% with anteroapical dyskinesia and no evidence of coronary artery disease. Our patient was diagnosed with Takotsubo cardiomyopathy after fulfilling all four of the Mayo Clinic's diagnostic criteria and was subsequently treated with a beta blocker, and angiotensin-converting enzyme inhibitor. Our patient did not have one clear trigger for her overt Takotsubo cardiomyopathy other than the Zumba activity. Zumba is considered an activity with excessive sympathetic stimulation leading to catecholamine-induced microvascular spasm or through to direct myocardial toxicity, which is postulated to be behind the pathophysiology of Takotsubo cardiomyopathy. Another interesting finding in our patient was her use of spironolactone, as treatment for hirsutism, which is an aldosterone antagonist. Aldosterone actually potentiates the effects of catecholamine and thus activates the sympathetic system. Spironolactone can thus be considered as cardioprotective against the effects of catecholamine on the heart and that is why it is considered to be beneficial and subsequently improves mortality in chronic heart failure as described in several studies.

  8. Sudden Death After Febrile Seizure Case Report: Cerebral Suppression Precedes Severe Bradycardia.

    PubMed

    Myers, Kenneth A; McPherson, Robyn E; Clegg, Robin; Buchhalter, Jeffrey

    2017-11-01

    A 20-month-old girl with a complex chromosomal disorder had first presentation of febrile status epilepticus and was admitted to the hospital. Two days after her initial seizure, she died suddenly and unexpectedly during a video EEG monitoring study. An advanced analysis of the physiologic changes in the hours and minutes leading up to death was undertaken. The electrocardiography over the last 19 minutes of life was reviewed, and the R-R intervals were manually measured. Heart rate variability was assessed through calculation of the SD of the R-R intervals and the root mean square of successive differences over successive 100 beat periods. Instantaneous heart rate, SD of the R-R intervals, the root mean square of successive differences, and oxygen saturation were plotted against time over the last 19 minutes of life. Diffuse cerebral suppression on EEG was observed 10 minutes before death, followed minutes later by severe bradycardia and increased heart rate variability. Although the child did not meet criteria for a diagnosis of epilepsy, the sequence of physiologic changes leading up to death suggests a pathophysiology similar to sudden unexplained death in epilepsy. A comparable pattern of diffuse cerebral suppression preceding parasympathetic overactivity has been suggested in some rare cases of adults who have experienced sudden unexplained death in epilepsy during video EEG monitoring. Copyright © 2017 by the American Academy of Pediatrics.

  9. A Modular Low-Complexity ECG Delineation Algorithm for Real-Time Embedded Systems.

    PubMed

    Bote, Jose Manuel; Recas, Joaquin; Rincon, Francisco; Atienza, David; Hermida, Roman

    2018-03-01

    This work presents a new modular and low-complexity algorithm for the delineation of the different ECG waves (QRS, P and T peaks, onsets, and end). Involving a reduced number of operations per second and having a small memory footprint, this algorithm is intended to perform real-time delineation on resource-constrained embedded systems. The modular design allows the algorithm to automatically adjust the delineation quality in runtime to a wide range of modes and sampling rates, from a ultralow-power mode when no arrhythmia is detected, in which the ECG is sampled at low frequency, to a complete high-accuracy delineation mode, in which the ECG is sampled at high frequency and all the ECG fiducial points are detected, in the case of arrhythmia. The delineation algorithm has been adjusted using the QT database, providing very high sensitivity and positive predictivity, and validated with the MIT database. The errors in the delineation of all the fiducial points are below the tolerances given by the Common Standards for Electrocardiography Committee in the high-accuracy mode, except for the P wave onset, for which the algorithm is above the agreed tolerances by only a fraction of the sample duration. The computational load for the ultralow-power 8-MHz TI MSP430 series microcontroller ranges from 0.2% to 8.5% according to the mode used.

  10. Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals.

    PubMed

    Jeyhani, Vala; Mahdiani, Shadi; Peltokangas, Mikko; Vehkaoja, Antti

    2015-01-01

    Heart rate variability (HRV) has become a useful tool in analysis of cardiovascular system in both research and clinical fields. HRV has been also used in other applications such as stress level estimation in wearable devices. HRV is normally obtained from ECG as the time interval of two successive R waves. Recently PPG has been proposed as an alternative for ECG in HRV analysis to overcome some difficulties in measurement of ECG. In addition, PPG-HRV is also used in some commercial devices such as modern optical wrist-worn heart rate monitors. However, some researches have shown that PPG is not a surrogate for heart rate variability analysis. In this work, HRV analysis was applied on beat-to-beat intervals obtained from ECG and PPG in 19 healthy male subjects. Some important HRV parameters were calculated from PPG-HRV and ECG-HRV. Maximum of PPG and its second derivative were considered as two methods for obtaining the beat-to-beat signals from PPG and the results were compared with those achieved from ECG-HRV. Our results show that the smallest error happens in SDNN and SD2 with relative error of 2.46% and 2%, respectively. The most affected parameter is pNN50 with relative error of 29.89%. In addition, in our trial, using the maximum of PPG gave better results than its second derivative.

  11. Severe tricuspid regurgitation in the aged: atrial remodeling associated with long-standing atrial fibrillation.

    PubMed

    Yamasaki, Naohito; Kondo, Fumiaki; Kubo, Toru; Okawa, Makoto; Matsumura, Yoshihisa; Kitaoka, Hiroaki; Yabe, Toshikazu; Furuno, Takashi; Doi, Yoshinori

    2006-12-01

    Severe idiopathic tricuspid regurgitation (TR) occurs in the aged, but the mechanism of TR is unclear and there is little information on atrial abnormalities associated with this condition. This study retrospectively analyzed patients with severe functional TR presenting with common clinical features suggesting a distinct syndrome. Eleven patients with severe functional TR were identified by reviewing the records of 16,235 consecutive patients. All patients had undergone clinical evaluation including echocardiography, electrocardiography and laboratory data. The median age of patients with severe functional TR was 78 years. All had a long-standing history of atrial fibrillation (median duration, 23 years). Clinical features are characterized by severe functional TR due to annular dilation, markedly dilated right atrium, episodes of right-sided heart failure, absent or diminished fibrillation waves on electrocardiogram, bradycardia probably due to partial atrial standstill, and decreased atrial natriuretic peptide secretion. During long-term follow up, right atrial size progressively increased in association with worsening TR. Severe functional TR occurs with long-standing atrial fibrillation and causes right-sided heart failure. The TR is caused by tricuspid valve systolic coaptation loss due to tricuspid annular dilation associated with atrial dilation. This condition is associated with atrial abnormalities, such as atrial standstill and impaired atrial natriuretic peptide secretion. We propose that atrial remodeling associated with atrial fibrillation is central to the occurrence of the syndrome.

  12. Respiratory function impairment and cardiopulmonary consequences in long-time residents of the Canadian Arctic.

    PubMed Central

    Schaefer, O; Eaton, R D; Timmermans, F J; Hildes, J A

    1980-01-01

    Spirometry, roentgenography and electrocardiography were performed during community health surveys in 1976-78 in 176 Inuit and other long-time residents of the northeastern (Arctic Bay) and western (Inuvik) Canadian Arctic, and the results were related to age, ethnic origin, occupation and history of climatic exposure, smoking and hospitalization for tuberculosis. In Arctic Bay the young men showed excellent respiratory function, normal-sized pulmonary arteries and normal electrocardiograms, but abnormalities of all three types were increasingly frequent and severe after age 25. The forced mid-expiratory flow (FMF) fell to less than 50% of the norm by age 40, and dilatation of the pulmonary artery, hypertrophy of the right ventricle, right bundle branch block and a pseudoinfarction pattern on the ECG were frequently associated. In contrast, the men in Inuvik, an urbanized centre, maintained above normal respiratory function until age 40, and the FMF and pulmonary artery diameter remained normal in the older men except for Inuit and white trappers over 60 years old who had run fox trap lines along the Arctic coast in the 1920s and 30s. These data suggest that inhalation of extremely cold air at maximum ventilation may be a prime factor in the chronic obstructive lung disease of Inuit hunters, whereas smoking has only a minor role and hospitalization for tuberculosis appears to protect from rather than contribute to this disorder. PMID:7448675

  13. Respiratory function impairment and cardiopulmonary consequences in long-time residents of the Canadian Arctic.

    PubMed

    Schaefer, O; Eaton, R D; Timmermans, F J; Hildes, J A

    1980-11-22

    Spirometry, roentgenography and electrocardiography were performed during community health surveys in 1976-78 in 176 Inuit and other long-time residents of the northeastern (Arctic Bay) and western (Inuvik) Canadian Arctic, and the results were related to age, ethnic origin, occupation and history of climatic exposure, smoking and hospitalization for tuberculosis. In Arctic Bay the young men showed excellent respiratory function, normal-sized pulmonary arteries and normal electrocardiograms, but abnormalities of all three types were increasingly frequent and severe after age 25. The forced mid-expiratory flow (FMF) fell to less than 50% of the norm by age 40, and dilatation of the pulmonary artery, hypertrophy of the right ventricle, right bundle branch block and a pseudoinfarction pattern on the ECG were frequently associated. In contrast, the men in Inuvik, an urbanized centre, maintained above normal respiratory function until age 40, and the FMF and pulmonary artery diameter remained normal in the older men except for Inuit and white trappers over 60 years old who had run fox trap lines along the Arctic coast in the 1920s and 30s. These data suggest that inhalation of extremely cold air at maximum ventilation may be a prime factor in the chronic obstructive lung disease of Inuit hunters, whereas smoking has only a minor role and hospitalization for tuberculosis appears to protect from rather than contribute to this disorder.

  14. [Epidemiology of early repolarization pattern in Maghreb].

    PubMed

    Amara, W; Bouallouche, S A; Rezoug, A; Hraiech, A El; Iusuf, A; Hammoudi, N

    2017-11-01

    An early repolarization variant (ERV) in inferolateral leads has recently been associated with vulnerability to ventricular fibrillation. These studies have been conducted in the occidental countries. The prevalence of ERV in the population of the Maghreb is unknown. The aim of this study was to evaluate the prevalence and risk factors of ERV in a young population from Algeria. We assessed the prevalence of ERV within a population of 441 healthy subjects (mean age 25 years) using 12-lead electrocardiography. ERV was stratified by three independent cardiologists according to the J-point elevation (≥0.1mV) in the inferior, apicolateral or both leads with QRS slurring or notching. The inferolateral ERV pattern was present in 55 subjects (12.4%). A malign ERV (>2mm) was present in 5 subjects (9% of ER) and ER in inferior and lateral leads in 40% of ER. An ERV pattern was more frequently associated with young age, male, bradycardia and T wave in V1 lead. An ERV is a common finding in a healthy Algerian young population. This prevalence seems to be more important than other studies due to young age and not to a racial difference. Our population were more at risk that other studies, and we found more T waves in V1 lead in this people, due to an ethnic particularities or a phenotypic association with the Brugada syndrome. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. [Risk factors associated with the diagnosis of chronic Chagasic miocardiopathy in seropositive individuals from Barinas state, Venezuela].

    PubMed

    González, Beatriz; Silva, Martha; Al-Atrache, Yusra; Delgado, Yelitze; Serrano, José Luis; Doccimo, Angelina; Hernández, Huber; Verde, Juan; Morillo, Daniela; Marín, Jaime; Concepción, Juan Luis; Bonfante-Cabarcas, Rafael; Rodríguez-Bonfante, Claudina

    2014-06-01

    This study evaluates the risk factors associated with the diagnosis of chronic chagasic miocardiopathy (CChM) in 115 seropositive individuals to anti-Trypanosoma cruzi antibodies, in Barinas state, Venezuela. Serology was performed with ELISA and MABA; while the CChM diagnosis was established by electrocardiography and echocardiography. A complete clinical history including epidemiological, personal/familiar antecedents and psychobiological habits, plus socioeconomic, psychosocial and alimentary habits interviews were performed for each individual. Risk factors were determined through binary logistic regression. Results showed that 81 patients (70,4%; CI 95% = 66.4-74.4) had criteria for CChM, of which 74 (64.4%; IC 95% = 60.2-68.6) were in phase II; while 34 (29.6%; IC 95% = 25.5-33.5) were in phase I of the disease and 7 (6.1%; IC 95% = 4.0-8.2) in phase III. In a one year period, two patients in phase III died of heart failure. The diagnosis of CChM was associated with hunting practice, maternal history of cardiopathies, chewing chimó, medical history of hypertension and apex beat visible; it was negatively associated with canned and preserved foods ingest. In conclusion the CChM diagnosis has high frequency in seropositive individuals in Barinas and heart failure prevention must be based on an early medical attention and educative strategies in order to control risk factors.

  16. [On the first studies of electrophysiology].

    PubMed

    de Micheli, Alfredo

    2011-01-01

    A historical outline of the evolution of electrophysiology from the eighteenth century is shortly presented. Topics concerning the so called animal electricity starting from the observations on descharges of Torpedo fish until Bolognese Galvani's researches on the frogs are exposed. The points of view of their oppositionists also are examined. These ones, leaded by the physicist Alessandro Volta, professor in the University of Pavia, believed that electricity detected by galvanists was not inherent to animal but was due to the action of the metallic conductors present in the circuit: contact electricity. Only towards the middle of the nineteenth century the physicist Carlo Matteucci attained to demonstrate the existente of the real animal electricity in form of injury current. It was possible to determine that quantitatively thanks to the capillary electrometer built in 1872 by the French physicist Gabriel Lippmann. This instrument was used by the English physiologist Waller in order to obtain the primitive electrocardiographic tracings in humans (1887). At beginnings of the twentieth century, the Dutch professor Willem Einthoven, of the University of Leiden, introduced his string galvanometer which permitted to allow the modern electrocardiography. So it was possible to record the electrical potentials of myocardial cells, first in vitro, later in isolated and perfused heart, son after in dog's heart in situ and finally in human heart. Therefore now it is possible to effectuate endocardial and epicardial mappings, indispensable in order to diagnose and treat the cardiac arrhythmias.

  17. Efficacy, Safety, and Tolerability of Armodafinil Therapy for Hypersomnia Associated With Dementia With Lewy Bodies: A Pilot Study

    PubMed Central

    Lapid, Maria I.; Kuntz, Karen M.; Mason, Sara S.; Aakre, Jeremiah A.; Lundt, Emily S.; Kremers, Walter; Allen, Laura A.; Drubach, Daniel A.; Boeve, Bradley F.

    2017-01-01

    Background/Aims Hypersomnia is common in dementia with Lewy bodies (DLB). We assessed the efficacy, safety, and tolerability of armodafinil for hypersomnia associated with DLB. Methods We performed a 12-week pilot trial of armodafinil therapy (125–250 mg orally daily) in DLB outpatients with hypersomnia. Patients underwent neurologic examinations, neuropsychological battery, laboratory testing, electrocardiography, and polysomnography. Efficacy was assessed at 2, 4, 8, and 12 weeks. Safety assessment included laboratory examinations, QTc interval, and heart rate. Tolerability was assessed by analysis of adverse events. Data were analyzed using the last-observation-carried-forward method. Results Of 20 participants, 17 completed the protocol. Median age was 72 years, most were men (80%), and most had spouses as caregivers. Epworth Sleepiness Scale (P<.001), Maintenance of Wakefulness Test (P=.003), and Clinical Global Impression of Change (P<.001) scores improved at week 12. Neuropsychiatric Inventory total score (P=.003), visual hallucinations (P=.003), and agitation (P=.02) improved at week 4. Caregiver overall quality of life improved at week 12 (P=.004). No adverse events occurred. Conclusion These pilot data suggest improvements in hypersomnia and wakefulness and reasonable safety and tolerability of armodafinil therapy in hypersomnolent patients with DLB. Our findings inform the use of pharmacologic strategies to manage hypersomnolence in these patients. PMID:28448998

  18. Influence of experimental oesophageal acidification on masseter muscle activity, cervicofacial behaviour and autonomic nervous activity in wakefulness.

    PubMed

    Ohmure, H; Sakoguchi, Y; Nagayama, K; Numata, M; Tsubouchi, H; Miyawaki, S

    2014-06-01

    Recent studies have been revealing the relationship between the stomatognathic system and the gastrointestinal tract. However, the effect of oesophageal acid stimulation on masticatory muscle activity during wakefulness has not been fully elucidated. To examine whether intra-oesophageal acidification induces masticatory muscle activity, a randomised trial was conducted investigating the effect of oesophageal acid infusion on masseter muscle activity, autonomic nervous system (ANS) activity and subjective symptoms. Polygraphic monitoring consisting of electromyography of the masseter muscle, electrocardiography and audio-video recording was performed in 15 healthy adult men, using three different 30-min interventions: (i) no infusion, (ii) intra-oesophageal saline infusion and (iii) intra-oesophageal infusion of acidic solution (0·1 N HCl; pH 1·2). This study was registered with the UMIN Clinical Trials Registry, UMIN000005350. Oesophageal acid stimulation significantly increased masseter muscle activity during wakefulness, especially when no behaviour was performed in the oro-facial region. Chest discomfort, including heartburn, also increased significantly after oesophageal acid stimulation; however, no significant correlation was observed between increased subjective symptoms and masseter muscle activity. Oesophageal acid infusion also altered ANS activity; a significant correlation was observed between masticatory muscle changes and parasympathetic nervous system activity. These findings suggest that oesophageal-derived ANS modulation induces masseter muscle activity, irrespective of the presence or absence of subjective gastrointestinal symptoms. © 2014 John Wiley & Sons Ltd.

  19. Evaluation of the Accuracy of Astroskin as a Behavioral Health Self-Monitoring System for Spaceflight

    NASA Technical Reports Server (NTRS)

    Kumar, Arun; Levin, Edwin; Cowings, Patricia; Toscano, William B.

    2015-01-01

    In space, there is a need to monitor astronauts' vital signs and assess their readiness to perform specific tasks during a mission. Currently, NASA does not have the capability to noninvasively monitor crew for extended periods of time. The Canadian Space Agency is working with the Psychophysiology Lab at NASA ARC to determine if the Astroskin could be used as a solution to this problem. Astroskin, a commercially available garment with built-in biosensors, can be comfortably worn under clothing or a spacesuit and relay information to the crewman's own mobile device. Data can also be sent wirelessly to the on-board Exploration Medical System. To determine if Astroskin meets requirements for health monitoring, it must first be validated in spaceflight analog environments. In the current study Astroskin data will be compared to traditional biomedical instrument measures of electrocardiography (ECG), respiration rate, and systolic blood pressure. The data will be recorded during Autogenic Feedback Training Exercise (AFTE), which is a type of physiological self-regulation training designed for astronauts. The data will also be recorded during simulations of the Orion spacecraft re-entry. The results to date suggest that Astroskin is a suitable ambulatory monitoring system that allows astronauts to self-diagnose and self-regulate adverse autonomic nervous system responses to sustained exposure to microgravity of spaceflight.

  20. Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room.

    PubMed

    Kamlin, C Omar F; Dawson, Jennifer A; O'Donnell, Colm P F; Morley, Colin J; Donath, Susan M; Sekhon, Jasbir; Davis, Peter G

    2008-06-01

    To determine the accuracy of heart rate obtained by pulse oximetry (HR(PO)) relative to HR obtained by 3-lead electrocardiography (HR(ECG)) in newborn infants in the delivery room. Immediately after birth, a preductal PO sensor and ECG leads were applied. PO and ECG monitor displays were recorded by a video camera. Two investigators reviewed the videos. Every two seconds, 1 of the investigators recorded HR(PO) and indicators of signal quality from the oximeter while masked to ECG, whereas the other recorded HR(ECG) and ECG signal quality while masked to PO. HR(PO) and HR(ECG) measurements were compared using Bland-Altman analysis. We attended 92 deliveries; 37 infants were excluded due to equipment malfunction. The 55 infants studied had a mean (+/-standard deviation [SD]) gestational age of 35 (+/-3.7) weeks, and birth weight 2399 (+/-869) g. In total, we analyzed 5877 data pairs. The mean difference (+/-2 SD) between HR(ECG) and HR(PO) was -2 (+/-26) beats per minute (bpm) overall and -0.5 (+/-16) bpm in those infants who received positive-pressure ventilation and/or cardiac massage. The sensitivity and specificity of PO for detecting HR(ECG) <100 bpm was 89% and 99%, respectively. PO provided an accurate display of newborn infants' HR in the delivery room, including those infants receiving advanced resuscitation.

  1. Heart Rate Assessment Immediately after Birth.

    PubMed

    Phillipos, Emily; Solevåg, Anne Lee; Pichler, Gerhard; Aziz, Khalid; van Os, Sylvia; O'Reilly, Megan; Cheung, Po-Yin; Schmölzer, Georg M

    2016-01-01

    Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. PubMed, EMBASE and Google Scholar were systematically searched using the following terms: 'infant', 'heart rate', 'monitoring', 'delivery room', 'resuscitation', 'stethoscope', 'auscultation', 'palpation', 'pulse oximetry', 'electrocardiogram', 'Doppler ultrasound', 'photoplethysmography' and 'wearable sensors'. Eighteen studies were identified that described various methods of heart rate assessment in newborn infants immediately after birth. Studies examining auscultation, palpation, pulse oximetry, electrocardiography and Doppler ultrasound as ways to measure heart rate were included. Heart rate measurements by pulse oximetry are superior to auscultation and palpation, but there is contradictory evidence about its accuracy depending on whether the sensor is connected to the infant or the oximeter first. Several studies indicate that electrocardiogram provides a reliable heart rate faster than pulse oximetry. Doppler ultrasound shows potential for clinical use, however future evidence is needed to support this conclusion. Heart rate assessment is important and there are many measurement methods. The accuracy of routinely applied methods varies, with palpation and auscultation being the least accurate and electrocardiogram being the most accurate. More research is needed on Doppler ultrasound before its clinical use. © 2015 S. Karger AG, Basel.

  2. Integrated heart failure telemonitoring system for homecare.

    PubMed

    Lobodzinski, S Suave; Jadalla, Ahlam A

    2010-01-01

    The integrated telemonitoring system (ITS) for homecare has been designed to improve quality of care as measured by increased nursing productivity, improved patients' clinical and behavioral outcomes and reduction of cost. The system incorporates managerial, organizational, operational and clinical tasks optimized for delivery of quality care through telemonitoring. A secure, multi-modal computer network that integrates homecare nurses, patients and those who care into one seamless environment has been developed. The network brings together a new generation of small, hand-held, wireless terminals used by nurses and patients with a HIPPA-compliant electronic patient record system at the caregiver's site. Wireless terminals use Gobi multi-standard networking technology for connectivity to any available wireless network. The unique features of ITS include a) picture recognition technology capable of extracting numeric data from in-home physiological signal monitor displays that include blood pressure, weight, oxygen saturation, transmission of lung sounds, and capturing echocardiography and electrocardiography data from mobile units; b) in-home caregiver-assisted interactive examinations of signs and symptoms that include visual impressions of ankle swelling, jugular vein distension measurement, and weight gain; c) video-conference capability, facilitating face-to-face two-way communication of nursing personnel with the patients. The ITS network has been designed to improve patients' clinical and behavioral outcomes, increase nursing productivity, and reduce the cost of homecare. Patients' co-operation and compliance has been achieved through use of easy-to-use videoconferencing terminals.

  3. The C-allele of tissue inhibitor of metalloproteinases 2 is associated with increased magnitude of QT dispersion prolongation in elderly Chinese - 4-year follow-up study.

    PubMed

    Lin, Tsung-Hsien; Chiu, Herng-Chia; Lee, Ya-Ting; Su, Ho-Ming; Juo, Suh-Hang Hank; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2007-01-01

    Matrix metalloproteinases (MMP) and tissue inhibitor of metalloproteinases (TIMP) trigger the signal cascade instigating cardiac remodeling and fibrosis, which lead to changes of repolarization variables. We investigate the influence of MMP9-1562 C/T and TIMP2-418 G/C gene polymorphisms on repolarization parameters including QT dispersion (QTd) and the peak and the end of the T wave interval (Tpe) in a prospective cohort. Of 1500 people screened, 106 elderly Chinese without organic heart disease were recruited and received electrocardiography at the baseline, second and 4th year follow-ups. The QTc (corrected QT), QTd, QTc dispersion (QTcd) and Tpe were manually calculated. Age was 72.7+/-4.1 y (range 62-81 y). QTd, QTcd and Tpe were significantly prolonged (all p <0.001 at the 2nd and 4th year). At the 4th year the magnitude of QTd prolongation but not Tpe was significantly higher in subjects carrying the TIMP2 C-allele than non C-allele carriers (p=0.033) as well as QTcd (p=0.010). This association was still significant in multivariate analyses (p=0.012 and p=0.003 for QTd and QTcd, respectively) but not in MMP9 genotype. The elderly Chinese with TIMP2 C-allele have higher magnitude of QTd and QTcd prolongation.

  4. An RF-induced voltage sensor for investigating pacemaker safety in MRI.

    PubMed

    Barbier, Thérèse; Piumatti, Roberto; Hecker, Bertrand; Odille, Freddy; Felblinger, Jacques; Pasquier, Cédric

    2014-12-01

    Magnetic resonance imaging (MRI) is inadvisable for patients with pacemakers, as radiofrequency (RF) voltages induced in the pacemaker leads may cause the device to malfunction. Our goal is to develop a sensor to measure such RF-induced voltages during MRI safety tests. A sensor was designed (16.6 cm(2)) for measuring voltages at the connection between the pacemaker lead and its case. The induced voltage is demodulated, digitized, and transferred by optical fibres. The sensor was calibrated on the bench using RF pulses of known amplitude and duration. Then the sensor was tested during MRI scanning at 1.5 T in a saline gel filled phantom. Bench tests showed measurement errors below 5% with a (-40 V; +40 V) range, a precision of 0.06 V, and a temporal resolution of 24.2 μs. In MRI tests, variability in the measured voltages was below 3.7% for 996 measurements with different sensors and RF exposure. Coupling between the sensor and the MRI electromagnetic environment was estimated with a second sensor connected and was below 6.2%. For a typical clinical MRI sequence, voltages around ten Vp were detected. We have built an accurate and reproducible tool for measuring RF-induced voltages in pacemaker leads during MR safety investigations. The sensor might also be used with other conducting cables including those used for electrocardiography and neurostimulation.

  5. Sick sinus syndrome in HCN1-deficient mice.

    PubMed

    Fenske, Stefanie; Krause, Stefanie C; Hassan, Sami I H; Becirovic, Elvir; Auer, Franziska; Bernard, Rebekka; Kupatt, Christian; Lange, Philipp; Ziegler, Tilman; Wotjak, Carsten T; Zhang, Henggui; Hammelmann, Verena; Paparizos, Christos; Biel, Martin; Wahl-Schott, Christian A

    2013-12-17

    Sinus node dysfunction (SND) is a major clinically relevant disease that is associated with sudden cardiac death and requires surgical implantation of electric pacemaker devices. Frequently, SND occurs in heart failure and hypertension, conditions that lead to electric instability of the heart. Although the pathologies of acquired SND have been studied extensively, little is known about the molecular and cellular mechanisms that cause congenital SND. Here, we show that the HCN1 protein is highly expressed in the sinoatrial node and is colocalized with HCN4, the main sinoatrial pacemaker channel isoform. To characterize the cardiac phenotype of HCN1-deficient mice, a detailed functional characterization of pacemaker mechanisms in single isolated sinoatrial node cells, explanted beating sinoatrial node preparation, telemetric in vivo electrocardiography, echocardiography, and in vivo electrophysiology was performed. On the basis of these experiments we demonstrate that mice lacking the pacemaker channel HCN1 display congenital SND characterized by bradycardia, sinus dysrhythmia, prolonged sinoatrial node recovery time, increased sinoatrial conduction time, and recurrent sinus pauses. As a consequence of SND, HCN1-deficient mice display a severely reduced cardiac output. We propose that HCN1 stabilizes the leading pacemaker region within the sinoatrial node and hence is crucial for stable heart rate and regular beat-to-beat variation. Furthermore, we suggest that HCN1-deficient mice may be a valuable genetic disease model for human SND.

  6. Analysis of the characteristics and management of critical values in a newborn tertiary center in China.

    PubMed

    Wang, Zheng-Li; Du, Li-Zhong; Chen, Yi-Yu; Li, Lu-Quan; Lu, Qi; Liu, Ying; Cao, Lu-Ying; He, Yu; Yu, Jia-Lin

    2017-02-01

    Critical value reporting has been widely adopted by hospitals throughout the world, but there were few reports about neonatal critical values. This study aimed to analyze characteristics of the neonatal critical values considered at our center and to provide information on improving neonatal intensive care. A retrospective study of critical values at a newborn tertiary center in China was conducted to assess neonatal critical values according to test, distribution, reporting time, patient outcome and the impact to the therapy. In total, 926 critical values were recorded. Overall, 66.52% (616/926) of the items were reported within 24 hours of admission, 50.28% (465/926) during duty times and 54.75% (507/926) in the neonatal intensive care unit (NICU). The routine coagulation test was the most frequent source of critical values. Electrocardiography, blood gas analysis and therapeutic drug monitoring of drug levels were associated with the highest rates of treatment intervention (100%); routine coagulation tests were the lowest (23.14%). Sample quality was the main cause of false-positive critical values. The incidence of neonatal critical values peaked during the first 24 hours post-admission and during duty periods. Each newborn center needs to enact rapid treatment guidelines to address common critical values in order to facilitate clinical interventions. Periodically reviewing critical values could help to optimize clinical practices.

  7. Evaluation of chronic arsenic poisoning due to consumption of contaminated ground water in West Bengal, India.

    PubMed

    Ghosh, Asutosh

    2013-08-01

    Chronic arsenic poisoning is an important public health problem and most notable in West Bengal and Bangladesh. In this study different systemic manifestations in chronic arsenic poisoning were evaluated. A nonrandomized, controlled, cross-sectional, observational study was carried out in Arsenic Clinic, Institute of Postgraduate Medical Education and Research, Kolkata, West Bengal, over a period of 1 year 4 months. Seventy-three cases diagnosed clinically, consuming water containing arsenic ≥50 μg/L and having hair and nail arsenic level >0.6 μg/L, were included. Special investigations included routine parameters and organ-specific tests. Arsenic levels in the drinking water, hair, and nail were measured in all. Twenty-five nonsmoker healthy controls were evaluated. Murshidabad and districts adjacent to Kolkata, West Bengal, were mostly affected. Middle-aged males were the common sufferers. Skin involvement was the commonest manifestation (100%), followed by hepatomegaly [23 (31.5%)] with or without transaminitis [7 (9.58%)]/portal hypertension [9 (12.33%)]. Restrictive abnormality in spirometry [11 (15.06%)], bronchiectasis [4 (5.47%)], interstitial fibrosis [2 (2.73%)], bronchogenic carcinoma [2 (2.73%)], oromucosal plaque [7 (9.58%)], nail hypertrophy [10 (13.69%)], alopecia [8 (10.95%)], neuropathy [5 (6.84%)], and Electrocardiography abnormalities [5 (6.84%)] were also observed. Mucocutaneous and nail lesions, hepatomegaly, and restrictive change in spirometry were the common and significant findings. Other manifestations were characteristic but insignificant.

  8. Heart rate variability in normal-weight patients with polycystic ovary syndrome.

    PubMed

    Kilit, Celal; Paşalı Kilit, Türkan

    2017-05-01

    Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.

  9. Time-varying spectral analysis revealing differential effects of sevoflurane anaesthesia: non-rhythmic-to-rhythmic ratio.

    PubMed

    Lin, Y-T; Wu, H-T; Tsao, J; Yien, H-W; Hseu, S-S

    2014-02-01

    Heart rate variability (HRV) may reflect various physiological dynamics. In particular, variation of R-R peak interval (RRI) of electrocardiography appears regularly oscillatory in deeper levels of anaesthesia and less regular in lighter levels of anaesthesia. We proposed a new index, non-rhythmic-to-rhythmic ratio (NRR), to quantify this feature and investigated its potential to estimate depth of anaesthesia. Thirty-one female patients were enrolled in this prospective study. The oscillatory pattern transition of RRI was visualised by the time-varying power spectrum and quantified by NRR. The prediction of anaesthetic events, including skin incision, first reaction of motor movement during emergence period, loss of consciousness (LOC) and return of consciousness (ROC) by NRR were evaluated by serial prediction probability (PK ) analysis; the ability to predict the decrease of effect-site sevoflurane concentration was also evaluated. The results were compared with Bispectral Index (BIS). NRR well-predicted first reaction (PK  > 0.90) 30 s ahead, earlier than BIS and significantly better than HRV indices. NRR well-correlated with sevoflurane concentration, although its correlation was inferior to BIS, while HRV indices had no such correlation. BIS indicated LOC and ROC best. Our findings suggest that NRR provides complementary information to BIS regarding the differential effects of anaesthetics on the brain, especially the subcortical motor activity. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Application of L1-norm regularization to epicardial potential reconstruction based on gradient projection.

    PubMed

    Wang, Liansheng; Qin, Jing; Wong, Tien Tsin; Heng, Pheng Ann

    2011-10-07

    The epicardial potential (EP)-targeted inverse problem of electrocardiography (ECG) has been widely investigated as it is demonstrated that EPs reflect underlying myocardial activity. It is a well-known ill-posed problem as small noises in input data may yield a highly unstable solution. Traditionally, L2-norm regularization methods have been proposed to solve this ill-posed problem. But the L2-norm penalty function inherently leads to considerable smoothing of the solution, which reduces the accuracy of distinguishing abnormalities and locating diseased regions. Directly using the L1-norm penalty function, however, may greatly increase computational complexity due to its non-differentiability. We propose an L1-norm regularization method in order to reduce the computational complexity and make rapid convergence possible. Variable splitting is employed to make the L1-norm penalty function differentiable based on the observation that both positive and negative potentials exist on the epicardial surface. Then, the inverse problem of ECG is further formulated as a bound-constrained quadratic problem, which can be efficiently solved by gradient projection in an iterative manner. Extensive experiments conducted on both synthetic data and real data demonstrate that the proposed method can handle both measurement noise and geometry noise and obtain more accurate results than previous L2- and L1-norm regularization methods, especially when the noises are large.

  11. Noninvasive identification of peripheral vessels of oral and maxillofacial regions by using electrocardiography-triggered three-dimensional fast asymmetric spin-echo sequences.

    PubMed

    Tanaka, Tatsurou; Oda, Masafumi; Kito, Shinji; Wakasugi-Sato, Nao; Matsumoto-Takeda, Shinobu; Otsuka, Kozue; Yoshioka, Izumi; Habu, Manabu; Kokuryo, Shinya; Kodama, Masaaki; Nogami, Shinnosuke; Miyamoto, Ikuya; Yamamoto, Noriaki; Ishikawa, Ayataka; Matsuo, Kou; Shiiba, Shunji; Seta, Yuji; Yamashita, Yoshihiro; Takahashi, Tetsu; Tominaga, Kazuhiro; Morimoto, Yasuhiro

    2011-10-01

    The aim of this study was to evaluate the 3-dimensional images of thinner main peripheral vessels in oral and maxillofacial regions made without contrast medium by using a new technique, fresh blood imaging (FBI). A second objective was to discern arteries from veins by using the combination of FBI with the subtraction technique. Images from FBI were compared with those from 3-dimensional phase-contrast magnetic resonance angiography (MRA) of blood vessels in 20 healthy subjects. All images were scored for visualization and image quality of the main blood vessels. In addition, appropriate flow-spoiled gradient pulses were applied to differentiate arteries from veins in the peripheral vasculature using a combination of FBI sequences and subtraction between systole- and diastole-triggered images. The scores of MRA using FBI for the visualization of thin blood vessels were significantly better than those using phase contrast, whereas scores for the visualization of main blood vessels were equal. Additionally, we succeeded in our initial attempt to differentiate arteries from veins with a reasonable acquisition time. Our initial experience shows that FBI could be a useful method to identify 3-dimensional vasculature and to differentiate arteries from veins among thinner peripheral vessels in the oral and maxillofacial regions without using contrast medium. Copyright © 2011 Mosby, Inc. All rights reserved.

  12. Requests for emergency hyperbaric oxygen treatment for carbon monoxide poisoning in Ankara, Turkey.

    PubMed

    Özgök-Kangal, Münïre Kübra; Karatop-Cesur, Iclal; Akcali, Gökhan; Yildiz, Senol; Uzun, Günalp

    2016-09-01

    Carbon monoxide (CO) poisoning is common in Turkey. Our department is the main provider of emergency hyperbaric oxygen therapy (HBOT) in Ankara and neighboring cities. In this study, we analyzed the characteristics of CO-poisoned patients who were referred by phone to our department for emergency HBOT. We retrospectively reviewed the records of phone consultations with emergency departments regarding the need for treatment of CO-poisoned patients with HBOT between 14 January 2014 and 14 January 2015. The following information was extracted from medical records: age, gender, CO source, exposure duration, carboxyhemoglobin (COHb) level, symptoms, electrocardiography (ECG) findings, cardiac enzymes, pregnancy, the distance of referring hospital to our centre, time between admission and consultation and HBOT decision. Over the one-year period, 562 patients with CO poisoning were referred for HBOT. We recommended HBOT for 289 (51%) patients. HBOT was recommended for 58% (n = 194) of the patients with COHb ≥ 25%, 72% (n = 163) of the patients with a history of syncope, 67% (n = 35) of the patients with ECG abnormality, and 67% (n = 14) of pregnant patients. Patients for whom HBOT was not recommended despite having positive signs of severe poisoning were referred significantly later compared to patients for whom HBOT was recommended. We found that the duration from admission to an emergency department to HBOT consultation affected our decision-making.

  13. The cardiovascular work of competitive dinghy sailing.

    PubMed

    Felici, F; Rodio, A; Madaffari, A; Ercolani, L; Marchetti, M

    1999-12-01

    Hiking is the special manoeuvre, which the dinghy sailor uses to counterbalance the capsizing effect of the wind on the boat. In the present research the work required of the heart by this exercise was studied in the laboratory using a boat simulator. Seven Laser male sailors selected from those in the first places in the junior national rank participated in this study. Their endurance, at different levels of isometric hiking efforts, was measured. Energy expenditure due to hiking was estimated from measurements of oxygen consumption, carbon dioxide elimination and blood lactate concentration. The cardiac load was evaluated by measuring blood pressure using the conventional method and heart rate measured by electrocardiography. Cardiac output was measured using the CO2 re-breathing method. Left ventricular work was then calculated as cardiac output multiplied by mean arterial pressure. The most relevant result was that, while whole body cost of hiking was relatively low (about 1 IO2 min-1), the power of the heart was very significant: cardiac output almost doubled with respect to that at rest and arterial mean pressure rose from 12.5 kPa (rest) to 18.5 kPa (hiking). Thus, left ventricular power rose from 1.2 Watt to 3.2 Watt, which is a typical cardiovascular response to muscular isometric contraction. These results assume relevance when a person's eligibility for sailing sports is evaluated.

  14. A Little Goes a Long Way: Low Working Memory Load Is Associated with Optimal Distractor Inhibition and Increased Vagal Control under Anxiety.

    PubMed

    Spangler, Derek P; Friedman, Bruce H

    2017-01-01

    Anxiety impairs both inhibition of distraction and attentional focus. It is unclear whether these impairments are reduced or exacerbated when loading working memory with non-affective information. Cardiac vagal control has been related to top-down regulation of anxiety; therefore, vagal control may reflect load-related inhibition of distraction under anxiety. The present study examined whether: (1) the enhancing and impairing effects of load on inhibition exist together in a non-linear function, (2) there is a similar association between inhibition and concurrent vagal control under anxiety. During anxiogenic threat-of-noise, 116 subjects maintained a digit series of varying lengths (0, 2, 4, and 6 digits) while completing a visual flanker task. The task was broken into four blocks, with a baseline period preceding each. Electrocardiography was acquired throughout to quantify vagal control as high-frequency heart rate variability (HRV). There were significant quadratic relations of working memory load to flanker performance and to HRV, but no associations between HRV and performance. Results indicate that low load was associated with relatively better inhibition and increased HRV. These findings suggest that attentional performance under anxiety depends on the availability of working memory resources, which might be reflected by vagal control. These results have implications for treating anxiety disorders, in which regulation of anxiety can be optimized for attentional focus.

  15. Prognostic significance of normal quantitative planar thallium-201 stress scintigraphy in patients with chest pain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wackers, F.J.; Russo, D.J.; Russo, D.

    The prognostic significance of normal quantitative planar thallium-201 stress scintigraphy was evaluated in patients with a chest pain syndrome. The prevalence of cardiac events during follow-up was related to the pretest (that is, before stress scintigraphy) likelihood of coronary artery disease determined on the basis of symptoms, age, sex and stress electrocardiography. In a consecutive series of 344 patients who had adequate thallium-201 stress scintigrams, 95 had unequivocally normal studies by quantitative analysis. The pretest likelihood of coronary artery disease in the 95 patients had a bimodal distribution. During a mean follow-up period of 22 +/- 3 months, no patientmore » died. Three patients (3%) had a cardiac event: two of these patients (pretest likelihood of coronary artery disease 54 and 94%) had a nonfatal myocardial infarction 8 and 22 months, respectively, after stress scintigraphy, and one patient (pretest likelihood 98%) underwent percutaneous transluminal coronary angioplasty 16 months after stress scintigraphy for persisting anginal complaints. Three patients were lost to follow-up; all three had a low pretest likelihood of coronary artery disease. It is concluded that patients with chest pain and normal findings on quantitative thallium-201 scintigraphy have an excellent prognosis. Cardiac events are rare (infarction rate 1% per year) and occur in patients with a moderate to high pretest likelihood of coronary artery disease.« less

  16. An Enhanced Method to Estimate Heart Rate from Seismocardiography via Ensemble Averaging of Body Movements at Six Degrees of Freedom.

    PubMed

    Lee, Hyunwoo; Lee, Hana; Whang, Mincheol

    2018-01-15

    Continuous cardiac monitoring has been developed to evaluate cardiac activity outside of clinical environments due to the advancement of novel instruments. Seismocardiography (SCG) is one of the vital components that could develop such a monitoring system. Although SCG has been presented with a lower accuracy, this novel cardiac indicator has been steadily proposed over traditional methods such as electrocardiography (ECG). Thus, it is necessary to develop an enhanced method by combining the significant cardiac indicators. In this study, the six-axis signals of accelerometer and gyroscope were measured and integrated by the L2 normalization and multi-dimensional kineticardiography (MKCG) approaches, respectively. The waveforms of accelerometer and gyroscope were standardized and combined via ensemble averaging, and the heart rate was calculated from the dominant frequency. Thirty participants (15 females) were asked to stand or sit in relaxed and aroused conditions. Their SCG was measured during the task. As a result, proposed method showed higher accuracy than traditional SCG methods in all measurement conditions. The three main contributions are as follows: (1) the ensemble averaging enhanced heart rate estimation with the benefits of the six-axis signals; (2) the proposed method was compared with the previous SCG method that employs fewer-axis; and (3) the method was tested in various measurement conditions for a more practical application.

  17. Multi-modal intelligent seizure acquisition (MISA) system--a new approach towards seizure detection based on full body motion measures.

    PubMed

    Conradsen, Isa; Beniczky, Sandor; Wolf, Peter; Terney, Daniella; Sams, Thomas; Sorensen, Helge B D

    2009-01-01

    Many epilepsy patients cannot call for help during a seizure, because they are unconscious or because of the affection of their motor system or speech function. This can lead to injuries, medical complications and at worst death. An alarm system setting off at seizure onset could help to avoid hazards. Today no reliable alarm systems are available. A Multi-modal Intelligent Seizure Acquisition (MISA) system based on full body motion data seems as a good approach towards detection of epileptic seizures. The system is the first to provide a full body description for epilepsy applications. Three test subjects were used for this pilot project. Each subject simulated 15 seizures and in addition performed some predefined normal activities, during a 4-hour monitoring with electromyography (EMG), accelerometer, magnetometer and gyroscope (AMG), electrocardiography (ECG), electroencephalography (EEG) and audio and video recording. The results showed that a non-subject specific MISA system developed on data from the modalities: accelerometer (ACM), gyroscope and EMG is able to detect 98% of the simulated seizures and at the same time mistakes only 4 of the normal movements for seizures. If the system is individualized (subject specific) it is able to detect all simulated seizures with a maximum of 1 false positive. Based on the results from the simulated seizures and normal movements the MISA system seems to be a promising approach to seizure detection.

  18. Diagnostic accuracy of a smartphone electrocardiograph in dogs: Comparison with standard 6-lead electrocardiography.

    PubMed

    Vezzosi, T; Buralli, C; Marchesotti, F; Porporato, F; Tognetti, R; Zini, E; Domenech, O

    2016-10-01

    The diagnostic accuracy of a smartphone electrocardiograph (ECG) in evaluating heart rhythm and ECG measurements was evaluated in 166 dogs. A standard 6-lead ECG was acquired for 1 min in each dog. A smartphone ECG tracing was simultaneously recorded using a single-lead bipolar ECG recorder. All ECGs were reviewed by one blinded operator, who judged if tracings were acceptable for interpretation and assigned an electrocardiographic diagnosis. Agreement between smartphone and standard ECG in the interpretation of tracings was evaluated. Sensitivity and specificity for the detection of arrhythmia were calculated for the smartphone ECG. Smartphone ECG tracings were interpretable in 162/166 (97.6%) tracings. A perfect agreement between the smartphone and standard ECG was found in detecting bradycardia, tachycardia, ectopic beats and atrioventricular blocks. A very good agreement was found in detecting sinus rhythm versus non-sinus rhythm (100% sensitivity and 97.9% specificity). The smartphone ECG provided tracings that were adequate for analysis in most dogs, with an accurate assessment of heart rate, rhythm and common arrhythmias. The smartphone ECG represents an additional tool in the diagnosis of arrhythmias in dogs, but is not a substitute for a 6-lead ECG. Arrhythmias identified by the smartphone ECG should be followed up with a standard ECG before making clinical decisions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Kulecz, Walter B.; DePalma, Jude L.; Feiveson, Alan H.; Wilson, John S.; Rahman, M. Atiar; Bungo, Michael W.

    2004-01-01

    Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

  20. Alpha lipoic acid intoxicatıon: An adult.

    PubMed

    Emir, Duygu Ferek; Ozturan, Ibrahim Ulas; Yilmaz, Serkan

    2018-06-01

    Alpha lipoic acid (ALA) is a potent antioxidant used to treat a variety of disorders. Although ALA is considered a very safe supplement and intoxication is very rare, acute high-dose ingestions can cause mortality. In this report, we discuss a very rare case of ALA intoxication to increase awareness of this issue. A 22-year-old female was referred to our emergency department with ALA intoxication after ingesting a total of 18g of ALA with a suicidal intention. The patient was found in an altered mental state and confused. During the physical examination, the patient's Glasgow Coma Scale was 13 (E4M6V3); however, she was neither alert nor oriented. Vital signs revealed a mildly decreased blood pressure, tachycardia, and an increased respiratory rate. Cranial nerve examination was normal except a horizontal gaze nystagmus. Laboratory testing showed a decompensated metabolic acidosis. T wave inversions were seen in the electrocardiography (EKG). The patient was treated with supportive treatment and discharged within three days of intensive care unit (ICU) admission. ALA is a very common supplement that is easily accessible worldwide. Although ALA intoxication is very rare, it is sometimes seen after accidental or suicidal acute ingestion. Neurologic effects, metabolic acidosis, and t wave inversions in the EKG are observed when this acute poisoning occurs. Supportive treatment should be the main therapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Usefulness of emergency ultrasound in nontraumatic cardiac arrest.

    PubMed

    Volpicelli, Giovanni

    2011-02-01

    Treatment of nontraumatic cardiac arrest in the hospital setting depends on the recognition of heart rhythm and differential diagnosis of the underlying condition while maintaining a constant oxygenated blood flow by ventilation and chest compression. Diagnostic process relies only on patient's history, physical findings, and active electrocardiography. Ultrasound is not currently scheduled in the resuscitation guidelines. Nevertheless, the use of real-time ultrasonography during resuscitation has the potential to improve diagnostic accuracy and allows the physician a greater confidence in deciding aggressive life-saving therapeutic procedures. This article reviews the current opinions and literature about the use of emergency ultrasound during resuscitation of nontraumatic cardiac arrest. Cardiac and lung ultrasound have a great potential in identifying the reversible mechanical causes of pulseless electrical activity or asystole. Brief examination of the heart can even detect a real cardiac standstill regardless of electrical activity displayed on the monitor, which is a crucial prognostic indicator. Moreover, ultrasound can be useful to verify and monitor the tracheal tube placement. Limitation to the use of ultrasound is the need to minimize the no-flow intervals during mechanical cardiopulmonary resuscitation. However, real-time ultrasound can be successfully applied during brief pausing of chest compression and first pulse-check. Finally, lung sonographic examination targeted to the detection of signs of pulmonary congestion has the potential to allow hemodynamic noninvasive monitoring before and after mechanical cardiopulmonary maneuvers. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Cardiac considerations in the triathlete.

    PubMed

    Douglas, P S

    1989-10-01

    The cardiac adaptation to exercise training produces a variety of adaptations in cardiac size, shape, and function. To further define these changes and to investigate the effects of maximal conditioning, we studied ultraendurance triathletes training for the Hawaii Ironman Triathlon using echocardiography, Doppler ultrasound, and electrocardiography. In this population, the left ventricle (LV) was of normal size but had increased wall thickness and mass. Systolic function was normal and diastolic function was normal or supernormal (increased ratio of rapid to atrial LV filling velocities). The finding of a pattern of concentric hypertrophy was reinforced by a close relationship between submaximal exercise systolic blood pressure and LV mass (r = 0.88). Examination of valvular function by Doppler ultrasound revealed significantly increased prevalences of mitral and tricuspid regurgitation in athletes, with 91% of athletes (vs 38% of controls) having regurgitation detected in at least one cardiac valve. Analysis of athletes using standard electrocardiographic criteria for the detection of left ventricular hypertrophy showed that these criteria did not reliably detect increased mass. However, changes such as marked QRS prolongation and nonvoltage criteria for LV hypertrophy and RV hypertrophy may be useful in separating physiologic from pathologic hypertrophy. Our studies provide additional descriptions of cardiac changes produced by ultraendurance exercise training and suggest that the hemodynamic load imposed by exercise may be a contributing cause to physiologic hypertrophy. Much yet remains to be learned about the cardiac adaptation to exercise training.

  3. Detection of atrial fibrillation with seismocardiography.

    PubMed

    Pankaala, Mikko; Koivisto, Tero; Lahdenoja, Olli; Kiviniemi, Tuomas; Saraste, Antti; Vasankari, Tuija; Airaksinen, Juhani

    2016-08-01

    In this paper we study the feasibility of seismocardiography (SCG) for the detection of Atrial Fibrillation (AF). In this preclinical study, data acquired from one patient having paroxysmal AF (no other heart diseases) is used to introduce specific changes in SCG signal due to AF. Observed changes and phenomena create a foundation for the development of SCG-based AF detection algorithms. SCG data was recorded from the sternum of an AF patient in dorso-ventral direction while at rest in a supine position using a three-axis high precision MEMS accelerometer simultaneously with a one-lead ECG. In contrast to ECG, the magnitude of beats registered with SCG varies considerably from beat to beat during AF. We show that the magnitude of the beats is not random but is in relation to beat intervals. It is shown that extra indicators for detecting AF become available when SCG data is combined with electrocardiographical (ECG) data; there is a certain behavior in the electromechanical delay characteristic of the AF. It is discussed how all this information can be taken advantage of in the detection of AF. Today electrocardiography (ECG) is the primary method for diagnosing arrhythmias, but there is a growing need for simpler and more convenient method for detecting asymptomatic AF. Given the very small dimensions of modern MEMS accelerometers (2mm×2mm), a reliable MEMS based measurement may provide totally new venues for arrhythmia detection.

  4. Rapid multislice T1 mapping of mouse myocardium: Application to quantification of manganese uptake in α-Dystrobrevin knockout mice.

    PubMed

    Jiang, Kai; Li, Wen; Li, Wei; Jiao, Sen; Castel, Laurie; Van Wagoner, David R; Yu, Xin

    2015-11-01

    The aim of this study was to develop a rapid, multislice cardiac T1 mapping method in mice and to apply the method to quantify manganese (Mn(2+)) uptake in a mouse model with altered Ca(2+) channel activity. An electrocardiography-triggered multislice saturation-recovery Look-Locker method was developed and validated both in vitro and in vivo. A two-dose study was performed to investigate the kinetics of T1 shortening, Mn(2+) relaxivity in myocardium, and the impact of Mn(2+) on cardiac function. The sensitivity of Mn(2+)-enhanced MRI in detecting subtle changes in altered Ca(2+) channel activity was evaluated in a mouse model with α-dystrobrevin knockout. Validation studies showed strong agreement between the current method and an established method. High Mn(2+) dose led to significantly accelerated T1 shortening. Heart rate decreased during Mn(2+) infusion, while ejection ratio increased slightly at the end of imaging protocol. No statistical difference in cardiac function was detected between the two dose groups. Mice with α-dystrobrevin knockout showed enhanced Mn(2+) uptake in vivo. In vitro patch-clamp study showed increased Ca(2+) channel activity. The saturation recovery method provides rapid T1 mapping in mouse hearts, which allowed sensitive detection of subtle changes in Mn(2+) uptake in α-dystrobrevin knockout mice. © 2014 Wiley Periodicals, Inc.

  5. Sensitivity and specificity of automated detection of early repolarization in standard 12-lead electrocardiography.

    PubMed

    Kenttä, Tuomas; Porthan, Kimmo; Tikkanen, Jani T; Väänänen, Heikki; Oikarinen, Lasse; Viitasalo, Matti; Karanko, Hannu; Laaksonen, Maarit; Huikuri, Heikki V

    2015-07-01

    Early repolarization (ER) is defined as an elevation of the QRS-ST junction in at least two inferior or lateral leads of the standard 12-lead electrocardiogram (ECG). Our purpose was to create an algorithm for the automated detection and classification of ER. A total of 6,047 electrocardiograms were manually graded for ER by two experienced readers. The automated detection of ER was based on quantification of the characteristic slurring or notching in ER-positive leads. The ER detection algorithm was tested and its results were compared with manual grading, which served as the reference. Readers graded 183 ECGs (3.0%) as ER positive, of which the algorithm detected 176 recordings, resulting in sensitivity of 96.2%. Of the 5,864 ER-negative recordings, the algorithm classified 5,281 as negative, resulting in 90.1% specificity. Positive and negative predictive values for the algorithm were 23.2% and 99.9%, respectively, and its accuracy was 90.2%. Inferior ER was correctly detected in 84.6% and lateral ER in 98.6% of the cases. As the automatic algorithm has high sensitivity, it could be used as a prescreening tool for ER; only the electrocardiograms graded positive by the algorithm would be reviewed manually. This would reduce the need for manual labor by 90%. © 2014 Wiley Periodicals, Inc.

  6. Professor Herman Burger (1893-1965), eminent teacher and scientist, who laid the theoretical foundations of vectorcardiography--and electrocardiography.

    PubMed

    van Herpen, Gerard

    2014-01-01

    Einthoven not only designed a high quality instrument, the string galvanometer, for recording the ECG, he also shaped the conceptual framework to understand it. He reduced the body to an equilateral triangle and the cardiac electric activity to a dipole, represented by an arrow (i.e. a vector) in the triangle's center. Up to the present day the interpretation of the ECG is based on the model of a dipole vector being projected on the various leads. The model is practical but intuitive, not physically founded. Burger analysed the relation between heart vector and leads according to the principles of physics. It then follows that an ECG lead must be treated as a vector (lead vector) and that the lead voltage is not simply proportional to the projection of the vector on the lead, but must be multiplied by the value (length) of the lead vector, the lead strength. Anatomical lead axis and electrical lead axis are different entities and the anatomical body space must be distinguished from electrical space. Appreciation of these underlying physical principles should contribute to a better understanding of the ECG. The development of these principles by Burger is described, together with some personal notes and a sketch of the personality of this pioneer of medical physics. Copyright © 2014. Published by Elsevier Inc.

  7. Right Ventricular Outflow Tract Septal Pacing Is Superior to Right Ventricular Apical Pacing

    PubMed Central

    Zou, Cao; Song, Jianping; Li, Hui; Huang, Xingmei; Liu, Yuping; Zhao, Caiming; Shi, Xin; Yang, Xiangjun

    2015-01-01

    Background The effects of right ventricular apical pacing (RVAP) and right ventricular outflow tract (RVOT) septal pacing on atrial and ventricular electrophysiology have not been thoroughly compared. Methods and Results To identify a more favorable pacing strategy with fewer adverse effects, 80 patients who had complete atrioventricular block with normal cardiac function and who were treated with either RVAP (n=42) or RVOT septal pacing (n=38) were recruited after an average of 2 years of follow‐up. The data from electrocardiography and echocardiography performed before pacemaker implantation and at the end of follow‐up were collected. The patients in the RVOT septal pacing and RVAP groups showed similar demographic and clinical characteristics before pacing treatments. After a mean follow‐up of 2 years, the final maximum P‐wave duration; P‐wave dispersion; Q‐, R‐, and S‐wave complex duration; left atrial volume index; left ventricular end‐systolic diameter; ratio of transmitral early diastolic filling velocity to mitral annular early diastolic velocity; and interventricular mechanical delay in the RVOT septal pacing group were significantly less than those in the RVAP group (P<0.05). The final left ventricular ejection fraction of the RVOT septal pacing group was significantly higher than that of the RVAP group (P<0.05). Conclusions Compared with RVAP, RVOT septal pacing has fewer adverse effects regarding atrial electrical activity and structure in patients with normal cardiac function. PMID:25896891

  8. WH Craib: a critical account of his work

    PubMed Central

    Naidoo, DP

    2009-01-01

    Summary Summary One hundred years after its introduction, the ECG remains the most commonly used cardiovascular laboratory procedure. It fulfils all the requirements of a diagnostic test: it is non-invasive, simple to record, highly reproducible and can be applied serially. It is the first laboratory test to be performed in a patient with chest pain, syncope or cardiac arrhythmias. It is also a prognostic tool that aids in risk stratification and clinical management. Among the many South Africans who have made remarkable contributions in the field of electrocardiography, Don Craib was the first to investigate the changing patterns of the ECG action potential in isolated skeletal muscle strips under varying conditions. It was during his stay at Johns Hopkins Hospital in Baltimore and Sir Thomas Lewis laboratory in London that Craib made singular observations about the fundamental origins of electrical signals in the skeletal muscle, and from these developed his hypothesis on the generation of the action potential in the electrocardiogram. His proposals went contrary to scientific opinion at the time and he was rebuffed by the scientific community. Frank Wilson subsequently went on to develop Craib’s doublet hypothesis into the dipole theory, acknowledging Craib’s work. Today the dipole theory is fundamental to the understanding of the spread of electrical activation in the myocardium and the genesis of the action potential. PMID:19287808

  9. [Scientometrics and bibliometrics of biomedical engineering periodicals and papers].

    PubMed

    Zhao, Ping; Xu, Ping; Li, Bingyan; Wang, Zhengrong

    2003-09-01

    This investigation was made to reveal the current status, research trend and research level of biomedical engineering in Chinese mainland by means of scientometrics and to assess the quality of the four domestic publications by bibliometrics. We identified all articles of four related publications by searching Chinese and foreign databases from 1997 to 2001. All articles collected or cited by these databases were searched and statistically analyzed for finding out the relevant distributions, including databases, years, authors, institutions, subject headings and subheadings. The source of sustentation funds and the related articles were analyzed too. The results showed that two journals were cited by two foreign databases and five Chinese databases simultaneously. The output of Journal of Biomedical Engineering was the highest. Its quantity of original papers cited by EI, CA and the totality of papers sponsored by funds were higher than those of the others, but the quantity and percentage per year of biomedical articles cited by EI were decreased in all. Inland core authors and institutions had come into being in the field of biomedical engineering. Their research topics were mainly concentrated on ten subject headings which included biocompatible materials, computer-assisted signal processing, electrocardiography, computer-assisted image processing, biomechanics, algorithms, electroencephalography, automatic data processing, mechanical stress, hemodynamics, mathematical computing, microcomputers, theoretical models, etc. The main subheadings were concentrated on instrumentation, physiopathology, diagnosis, therapy, ultrasonography, physiology, analysis, surgery, pathology, method, etc.

  10. User Interactive Software for Analysis of Human Physiological Data

    NASA Technical Reports Server (NTRS)

    Cowings, Patricia S.; Toscano, William; Taylor, Bruce C.; Acharya, Soumydipta

    2006-01-01

    Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration

  11. Selected clinical, biochemical, and electrolyte alterations in anesthetized captive tigers (Panthera tigris) and lions (Panthera leo).

    PubMed

    Reilly, Sabrina; Seddighi, M Reza; Steeil, James C; Sura, Patricia; Whittemore, Jacqueline C; Gompf, Rebecca E; Elliott, Sarah B; Ramsay, Edward C

    2014-06-01

    A prospective study to assess changes in selected plasma biochemistry and electrolyte values, plasma insulin and aldosterone concentrations, and electrocardiography (ECG) was performed on eight female captive tigers (Panthera tigris) and three lions (Panthera leo) undergoing general anesthesia for elective laparoscopic ovariectomy. Each animal was sedated with medetomidine (18-25 microg/kg) and midazolam (0.06-0.1 mg/kg) intramuscularly, and anesthesia was induced with ketamine (1.9-3.5 mg/kg) intramuscularly and maintained with isoflurane. Venous blood samples were collected and analyzed for plasma biochemistry parameters and insulin and aldosterone concentrations. An ECG was recorded at the time of each blood sample collection. Mean plasma potassium, glucose, phosphorus, and aldosterone concentrations increased during anesthesia (P < or = 0.05). One tiger developed hyperkalemia (6.5 mmol/L) 2.5 hr after anesthetic induction. Plasma insulin concentrations were initially below the low end of the domestic cat reference interval (72-583 pmol/L), but mean insulin concentration increased (P < or = 0.05) over time compared with the baseline values. Three tigers and two lions had ECG changes that were representative of myocardial hypoxemia. Based on these results, continuous monitoring of clinical and biochemical alterations during general anesthesia in large nondomestic felids is warranted, and consideration should be given to reversal of medetomidine in these animals should significant changes in electrolytes or ECG occur.

  12. Trastuzumab (Herceptin)-associated cardiomyopathy presented as new onset of complete left bundle-branch block mimicking acute coronary syndrome: a case report and literature review.

    PubMed

    Tu, Chung-Ming; Chu, Kai-Ming; Yang, Shin-Ping; Cheng, Shu-Mung; Wang, Wen-Been

    2009-09-01

    Trastuzumab (Herceptin) is well documented in reducing suffering and mortality from breast cancer. The clinically most important side effect of Herceptin is cardiotoxicity, which is reported in 2.6% to 4.5% of patients receiving trastuzumab alone and in as many as 27% of patients when trastuzumab is combined with an anthracycline in metastatic disease. We reported the case of a 50-year-old woman who presented to our emergency department (ED) because of chest pain and shortness of breath. On physical examination, holosystolic murmur over apex could be heard. Pulmonary and abdominal examinations were unremarkable. Twelve-lead electrocardiography showed sinus tachycardia and new onset of complete left bundle-branch block. Emergent transthoracic echocardiography revealed generalized hypokinesia of left ventricle and akinesia over interventricular septum and apex. She subsequently underwent immediate coronary angiography that revealed normal coronary angiography, and left ventriculogram revealed generalized hypokinesia with severe left ventricle dysfunction with ejection fraction of 33%. During right heart catheterization and endomyocardial biopsy, cardiac tamponade developed and was successfully relieved by pericardial window. She was discharged event-free 3 weeks later with conservative treatment. Although new onset of complete left bundle-branch block in a patient with chest pain may be acute coronary syndrome, careful review of medicine history is mandatory to avoid unnecessary procedure and complications.

  13. Teaching metacognition in clinical decision-making using a novel mnemonic checklist: an exploratory study

    PubMed Central

    Chew, Keng Sheng; Durning, Steven J; van Merriënboer, Jeroen JG

    2016-01-01

    INTRODUCTION Metacognition is a cognitive debiasing strategy that clinicians can use to deliberately detach themselves from the immediate context of a clinical decision, which allows them to reflect upon the thinking process. However, cognitive debiasing strategies are often most needed when the clinician cannot afford the time to use them. A mnemonic checklist known as TWED (T = threat, W = what else, E = evidence and D = dispositional factors) was recently created to facilitate metacognition. This study explores the hypothesis that the TWED checklist improves the ability of medical students to make better clinical decisions. METHODS Two groups of final-year medical students from Universiti Sains Malaysia, Malaysia, were recruited to participate in this quasi-experimental study. The intervention group (n = 21) received educational intervention that introduced the TWED checklist, while the control group (n = 19) received a tutorial on basic electrocardiography. Post-intervention, both groups received a similar assessment on clinical decision-making based on five case scenarios. RESULTS The mean score of the intervention group was significantly higher than that of the control group (18.50 ± 4.45 marks vs. 12.50 ± 2.84 marks, p < 0.001). In three of the five case scenarios, students in the intervention group obtained higher scores than those in the control group. CONCLUSION The results of this study support the use of the TWED checklist to facilitate metacognition in clinical decision-making. PMID:26778635

  14. Electrocardiography in two subspecies of manatee (Trichechus manatus latirostris and Trichechus manatus manatus)

    USGS Publications Warehouse

    Siegal-Willott, J.; Estrada, A.; Bonde, R.K.; Wong, A.; Estrada, D.J.; Harr, K.

    2006-01-01

    Electrocardiographic (ECG) measurements were recorded in two subspecies of awake, apparently healthy, wild manatees (Trichechus manatus latirostris and T. m. manatus) undergoing routine field examinations in Florida and Belize. Six unsedated juveniles (dependent and independent calves) and 6 adults were restrained in ventral recumbency for ECG measurements. Six lead ECGs were recorded for all manatees and the following parameters were determined: heart rate and rhythm; P, QRS, and T wave morphology, amplitude, and duration; and mean electrical axis (MEA). Statistical differences using a t-test for equality of means were determined. No statistical difference was seen based on sex or subspecies of manatees in the above measured criteria. Statistical differences existed in heart rate (P = 0.047), P wave duration (P = 0.019), PR interval (P = 0.025), and MEA (P = 0.021) between adult manatees and calves. Our findings revealed normal sinus rhythms, no detectable arrhythmias, prolonged PR and QT intervals, prolonged P wave duration, and small R wave amplitude as compared with cetacea and other marine mammals. This paper documents the techniques for and baseline recordings of ECGs in juvenile and adult free-living manatees. It also demonstrates that continual assessment of cardiac electrical activity in the awake manatee can be completed and can be used to aid veterinarians and biologists in routine health assessment, during procedures, and in detecting the presence of cardiac disease or dysfunction.

  15. Regional Cerebral Oximetry During Cardiopulmonary Resuscitation: Useful or Useless?

    PubMed

    Genbrugge, Cornelia; Dens, Jo; Meex, Ingrid; Boer, Willem; Eertmans, Ward; Sabbe, Marc; Jans, Frank; De Deyne, Cathy

    2016-01-01

    Approximately 375,000 people annually experience sudden cardiac arrest (CA) in Europe. Most patients who survive the initial hours and days after CA die of postanoxic brain damage. Current monitors, such as electrocardiography and end-tidal capnography, provide only indirect information about the condition of the brain during cardiopulmonary resuscitation (CPR). In contrast, cerebral near-infrared spectroscopy provides continuous, noninvasive, real-time information about brain oxygenation without the need for a pulsatile blood flow. It measures transcutaneous cerebral tissue oxygen saturation (rSO2). This information could supplement currently used monitors. Moreover, an evolution in rSO2 monitoring technology has made it easier to assess rSO2 in CA conditions. We give an overview of the literature regarding rSO2 measurements during CPR and the current commercially available devices. We highlight the feasibility of cerebral saturation measurement during CPR, its role as a quality parameter of CPR, predictor of return of spontaneous circulation (ROSC) and neurologic outcome, and its monitoring function during transport. rSO2 is feasible in the setting of CA and has the potential to measure the quality of CPR, predict ROSC and neurologic outcome, and monitor post-CA patients during transport. The literature shows that rSO2 has the potential to serve multiple roles as a neuromonitoring tool during CPR and also to guide neuroprotective therapeutic strategies. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Association between atrial fibrillation, atrial enlargement, and left ventricular geometric remodeling.

    PubMed

    Seko, Yuta; Kato, Takao; Haruna, Tetsuya; Izumi, Toshiaki; Miyamoto, Shoichi; Nakane, Eisaku; Inoko, Moriaki

    2018-04-23

    This study investigated the relationship between atrial fibrillation (AF) and left ventricular (LV) geometric patterns in a hospital-based population in Japan. We retrospectively analyzed 4444 patients who had undergone simultaneous scheduled transthoracic echocardiography (TTE) and electrocardiography during 2013. A total of 430 patients who had findings of previous myocardial infarctions (n = 419) and without the data on body surface area (n = 11) were excluded from the study. We calculated the LV mass index (LVMI) and relative wall (RWT) and categorized 4014 patients into four groups as follows: normal geometry (n = 3046); concentric remodeling (normal LVMI and high RWT, n = 437); concentric hypertrophy (high LVMI and high RWT, n = 149); and eccentric remodeling (high LVMI and normal RWT, n = 382). The mean left atrial volume indices (LAVI) were 22.5, 23.8, 33.3, and 37.0 mm/m 2 in patients with normal geometry, concentric remodeling, concentric hypertrophy, and eccentric hypertrophy, respectively. The mean LV ejection fractions (LVEF) were 62.7, 62.6, 60.8, and 53.8%, respectively, whereas the prevalence of AF was 10.4%, 10.5%, 14.8%, and 16.8% in patients with normal geometry, concentric remodeling, concentric hypertrophy, and eccentric hypertrophy, respectively. In conclusion, the prevalence of AF was increasing according to LV geometric remodeling patterns in association with LA size and LVEF.

  17. An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment

    PubMed Central

    Rundo, Francesco; Ortis, Alessandro

    2018-01-01

    Physiological signals are widely used to perform medical assessment for monitoring an extensive range of pathologies, usually related to cardio-vascular diseases. Among these, both PhotoPlethysmoGraphy (PPG) and Electrocardiography (ECG) signals are those more employed. PPG signals are an emerging non-invasive measurement technique used to study blood volume pulsations through the detection and analysis of the back-scattered optical radiation coming from the skin. ECG is the process of recording the electrical activity of the heart over a period of time using electrodes placed on the skin. In the present paper we propose a physiological ECG/PPG “combo” pipeline using an innovative bio-inspired nonlinear system based on a reaction-diffusion mathematical model, implemented by means of the Cellular Neural Network (CNN) methodology, to filter PPG signal by assigning a recognition score to the waveforms in the time series. The resulting “clean” PPG signal exempts from distortion and artifacts is used to validate for diagnostic purpose an EGC signal simultaneously detected for a same patient. The multisite combo PPG-ECG system proposed in this work overpasses the limitations of the state of the art in this field providing a reliable system for assessing the above-mentioned physiological parameters and their monitoring over time for robust medical assessment. The proposed system has been validated and the results confirmed the robustness of the proposed approach. PMID:29385774

  18. An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment.

    PubMed

    Rundo, Francesco; Conoci, Sabrina; Ortis, Alessandro; Battiato, Sebastiano

    2018-01-30

    Physiological signals are widely used to perform medical assessment for monitoring an extensive range of pathologies, usually related to cardio-vascular diseases. Among these, both PhotoPlethysmoGraphy (PPG) and Electrocardiography (ECG) signals are those more employed. PPG signals are an emerging non-invasive measurement technique used to study blood volume pulsations through the detection and analysis of the back-scattered optical radiation coming from the skin. ECG is the process of recording the electrical activity of the heart over a period of time using electrodes placed on the skin. In the present paper we propose a physiological ECG/PPG "combo" pipeline using an innovative bio-inspired nonlinear system based on a reaction-diffusion mathematical model, implemented by means of the Cellular Neural Network (CNN) methodology, to filter PPG signal by assigning a recognition score to the waveforms in the time series. The resulting "clean" PPG signal exempts from distortion and artifacts is used to validate for diagnostic purpose an EGC signal simultaneously detected for a same patient. The multisite combo PPG-ECG system proposed in this work overpasses the limitations of the state of the art in this field providing a reliable system for assessing the above-mentioned physiological parameters and their monitoring over time for robust medical assessment. The proposed system has been validated and the results confirmed the robustness of the proposed approach.

  19. Randomised controlled trial of routine individual feedback to improve rationality and reduce numbers of test requests.

    PubMed

    Winkens, R A; Pop, P; Bugter-Maessen, A M; Grol, R P; Kester, A D; Beusmans, G H; Knottnerus, J A

    1995-02-25

    Feedback can be described as a way to provide information on doctors' performance to enable changes in future behaviour. Feedback is used with the aim of changing test-ordering behaviour. It can lead to reductions in test usage and cost savings. It is not sufficiently clear, however, whether feedback leads to more appropriate test use. Since 1985, the Diagnostic Coordinating Center Maastricht has been giving feedback on diagnostic tests as a routine health care activity to all family doctors in its region. Both quantity and quality of requests are discussed. In a randomised, controlled trial over 2.5 years, discussion of tests not included previously was added to the existing routine feedback. One group of family doctors (n = 39) received feedback on test-group A (electrocardiography, endoscopy, cervical smears, and allergy tests), the other (n = 40) on test-group B (radiographic and ultrasonographic tests). Thus, each group of doctors acted as a control group for the other. Changes in volume and rationality of requests were analysed. The number of requests decreased during the trial (p = 0.036). Request numbers decreased particularly for test-group A (p = 0.04). The proportion of requests that were non-rational decreased more in the intervention than in the control groups (p = 0.009). Rationality improved predominantly for test-group B (p = 0.043). Thus, routine feedback can change the quantity and quality of requests.

  20. Compressed ECG biometric: a fast, secured and efficient method for identification of CVD patient.

    PubMed

    Sufi, Fahim; Khalil, Ibrahim; Mahmood, Abdun

    2011-12-01

    Adoption of compression technology is often required for wireless cardiovascular monitoring, due to the enormous size of Electrocardiography (ECG) signal and limited bandwidth of Internet. However, compressed ECG must be decompressed before performing human identification using present research on ECG based biometric techniques. This additional step of decompression creates a significant processing delay for identification task. This becomes an obvious burden on a system, if this needs to be done for a trillion of compressed ECG per hour by the hospital. Even though the hospital might be able to come up with an expensive infrastructure to tame the exuberant processing, for small intermediate nodes in a multihop network identification preceded by decompression is confronting. In this paper, we report a technique by which a person can be identified directly from his / her compressed ECG. This technique completely obviates the step of decompression and therefore upholds biometric identification less intimidating for the smaller nodes in a multihop network. The biometric template created by this new technique is lower in size compared to the existing ECG based biometrics as well as other forms of biometrics like face, finger, retina etc. (up to 8302 times lower than face template and 9 times lower than existing ECG based biometric template). Lower size of the template substantially reduces the one-to-many matching time for biometric recognition, resulting in a faster biometric authentication mechanism.

Top