Sample records for electrocoagulation ec process

  1. Electrocoagulation in Water Treatment

    NASA Astrophysics Data System (ADS)

    Liu, Huijuan; Zhao, Xu; Qu, Jiuhui

    Electrocoagulation (EC) is an electrochemical method of treating polluted water where sacrificial anodes corrode to release active coagulant precursors (usually aluminum or iron cations) into solution. At the cathode, gas evolves (usually as hydrogen bubbles) accompanying electrolytic reactions. EC needs simple equipments and is designable for virtually any size. It is cost effective and easily operable. Specially, the recent technical improvements combined with a growing need for small-scale water treatment facilities have led to a revaluation of EC. In this chapter, the basic principle of EC was introduced first. Following that, reactions at the electrodes and electrode assignment were reviewed; electrode passivation process and activation method were presented; comparison between electrocoagulation and chemical coagulation was performed; typical design of the EC reactors was also described; and factors affecting electrocoagulation including current density, effect of conductivity, temperature, and pH were introduced in details. Finally, application of EC in water treatment was given in details.

  2. Removal of micropollutants from municipal wastewater by graphene adsorption and simultaneous electrocoagulation/electrofiltration process.

    PubMed

    Yang, Gordon C C; Tang, Pei-Ling; Yen, Chia-Heng

    2017-04-01

    In this work the optimal operating conditions for removing selected micropollutants (also known as emerging contaminants, ECs) from actual municipal wastewater by graphene adsorption (GA) and simultaneous electrocoagulation/electrofiltration (EC/EF) process, respectively, were first determined and evaluated. Then, performance and mechanisms for the removal of selected phthalates and pharmaceuticals from municipal wastewater simultaneously by the GA and EC/EF process were further assessed. ECs of concern included di-n-butyl phthalate (DnBP), di-(2-ethylhexyl) phthalate (DEHP), acetaminophen (ACE), caffeine (CAF), cefalexin (CLX) and sulfamethoxazole (SMX). It was found that GA plus EC/EF process yielded the following removal efficiencies: DnBP, 89 ± 2%; DEHP, 85 ± 3%; ACE, 99 ± 2%; CAF, 94 ± 3%; CLX, 100 ± 0%; and SMX, 98 ± 2%. Carbon adsorption, size exclusion, electrostatic repulsion, electrocoagulation, and electrofiltration were considered as the main mechanisms for the removal of target ECs by the integrated process indicated above.

  3. Application of Electrocoagulation In Various Wastewater And Leachate Treatment-A Review

    NASA Astrophysics Data System (ADS)

    Zailani, L. W. M.; Zin, N. S. M.

    2018-04-01

    Electrocoagulation is a method that has a great ability on various wastewater and leachate treatment. It has a potential in removing various pollutants such as chemical oxygen demand, turbidity, ammonia, color, and suspended solid. The effectiveness of electrocoagulation method depends on several factors such as electrode, current density, operation time and pH. The aim of this paper is to review the relevant literature that publishes from 2000 to 2015 on the factor that influence Electrocoagulation (EC). The review describes, discussing and compare the factors that influence the EC process in various wastewater and leachate treatment.

  4. Arsenic removal by electrocoagulation process: Recent trends and removal mechanism.

    PubMed

    Nidheesh, P V; Singh, T S Anantha

    2017-08-01

    Arsenic contamination in drinking water is a major issue in the present world. Arsenicosis is the disease caused by the regular consumption of arsenic contaminated water, even at a lesser contaminated level. The number of arsenicosis patients is increasing day-by-day. Decontamination of arsenic from the water medium is the only one way to regulate this and the arsenic removal can be fulfilled by water treatment methods based on separation techniques. Electrocoagulation (EC) process is a promising technology for the effective removal of arsenic from aqueous solution. The present review article analyzes the performance of the EC process for arsenic removal. Electrocoagulation using various sacrificial metal anodes such as aluminium, iron, magnesium, etc. is found to be very effective for arsenic decontamination. The performances of each anode are described in detail. A special focus has been made on the mechanism behind the arsenite and arsenate removal by EC process. Main trends in the disposal methods of sludge containing arsenic are also included. Comparison of arsenic decontamination efficiencies of chemical coagulation and EC is also reported. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Treatment of leachate by electrocoagulation using aluminum and iron electrodes.

    PubMed

    Ilhan, Fatih; Kurt, Ugur; Apaydin, Omer; Gonullu, M Talha

    2008-06-15

    In this paper, treatment of leachate by electrocoagulation (EC) has been investigated in a batch process. The sample of leachate was supplied from Odayeri Landfill Site in Istanbul. Firstly, EC was compared with classical chemical coagulation (CC) process via COD removal. The first comparison results with 348 A/m2 current density showed that EC process has higher treatment performance than CC process. Secondly, effects of process variables such as electrode material, current density (from 348 to 631 A/m2), pH, treatment cost, and operating time for EC process are investigated on COD and NH4-N removal efficiencies. The appropriate electrode type search for EC provided that aluminum supplies more COD removal (56%) than iron electrode (35%) at the end of the 30 min operating time. Finally, EC experiments were also continued to determine the efficiency of ammonia removal, and the effects of current density, mixing, and aeration. All the findings of the study revealed that treatment of leachate by EC can be used as a step of a joint treatment.

  6. Removal of malachite green from aqueous solutions by electrocoagulation/peanut shell adsorption coupling in a batch system.

    PubMed

    Wang, Xiansheng; Ni, Jiaheng; Pang, Shuo; Li, Ying

    2017-04-01

    A electrocoagulation (EC)/peanut shell (PS) adsorption coupling technique was studied for the removal of malachite green (MG) in our present work. The addition of an appropriate PS dosage (5 g/L) resulted in remarkable increase in the removal efficiency of MG at lower current density and shorter operating time compared with the conventional EC process. The effect of current density, pH of MG solution, dosage of PS and initial concentration of MG were also investigated. The maximum removal efficiency of MG was 98% under optimum conditions in 5 min. And it was 23% higher than that in EC process. Furthermore, the unit energy demand (UED) and the unit electrode material demand (UEMD) were calculated and discussed. The results demonstrated that the EC/PS adsorption coupling method achieved a reduction of 94% UED and UEMD compared with EC process.

  7. Optimization of electrocoagulation process to treat grey wastewater in batch mode using response surface methodology.

    PubMed

    Karichappan, Thirugnanasambandham; Venkatachalam, Sivakumar; Jeganathan, Prakash Maran

    2014-01-10

    Discharge of grey wastewater into the ecological system causes the negative impact effect on receiving water bodies. In this present study, electrocoagulation process (EC) was investigated to treat grey wastewater under different operating conditions such as initial pH (4-8), current density (10-30 mA/cm2), electrode distance (4-6 cm) and electrolysis time (5-25 min) by using stainless steel (SS) anode in batch mode. Four factors with five levels Box-Behnken response surface design (BBD) was employed to optimize and investigate the effect of process variables on the responses such as total solids (TS), chemical oxygen demand (COD) and fecal coliform (FC) removal. The process variables showed significant effect on the electrocoagulation treatment process. The results were analyzed by Pareto analysis of variance (ANOVA) and second order polynomial models were developed in order to study the electrocoagulation process statistically. The optimal operating conditions were found to be: initial pH of 7, current density of 20 mA/cm2, electrode distance of 5 cm and electrolysis time of 20 min. These results indicated that EC process can be scale up in large scale level to treat grey wastewater with high removal efficiency of TS, COD and FC.

  8. Improvement of the Performance of an Electrocoagulation Process System Using Fuzzy Control of pH.

    PubMed

    Demirci, Yavuz; Pekel, Lutfiye Canan; Altinten, Ayla; Alpbaz, Mustafa

    2015-12-01

    The removal efficiencies of electrocoagulation (EC) systems are highly dependent on the initial value of pH. If an EC system has an acidic influent, the pH of the effluent increases during the treatment process; conversely, if such a system has an alkaline influent, the pH of the effluent decreases during the treatment process. Thus, changes in the pH of the wastewater affect the efficiency of the EC process. In this study, we investigated the dynamic effects of pH. To evaluate approaches for preventing increases in the pH of the system, the MATLAB/Simulink program was used to develop and evaluate an on-line computer-based system for pH control. The aim of this work was to study Proportional-Integral-Derivative (PID) control and fuzzy control of the pH of a real textile wastewater purification process using EC. The performances and dynamic behaviors of these two control systems were evaluated based on determinations of COD, colour, and turbidity removal efficiencies.

  9. Comparison of COD removal from pharmaceutical wastewater by electrocoagulation, photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes.

    PubMed

    Farhadi, Sajjad; Aminzadeh, Behnoush; Torabian, Ali; Khatibikamal, Vahid; Alizadeh Fard, Mohammad

    2012-06-15

    This work makes a comparison between electrocoagulation (EC), photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes to investigate the removal of chemical oxygen demand (COD) from pharmaceutical wastewater. The effects of operational parameters such as initial pH, current density, applied voltage, amount of hydrogen peroxide and electrolysis time on COD removal efficiency were investigated and the optimum operating range for each of these operating variables was experimentally determined. In electrocoagulation process, the optimum values of pH and voltage were determined to be 7 and 40 V, respectively. Desired pH and hydrogen peroxide concentration in the Fenton-based processes were found to be 3 and 300 mg/L, respectively. The amounts of COD, pH, electrical conductivity, temperature and total dissolved solids (TDS) were on-line monitored. Results indicated that under the optimum operating range for each process, the COD removal efficiency was in order of peroxi-electrocoagulation > peroxi-photoelectrocoagulation > photoelectrocoagulation>electrocoagulation. Finally, a kinetic study was carried out using the linear pseudo-second-order model and results showed that the pseudo-second-order equation provided the best correlation for the COD removal rate. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Integrated electrocoagulation-electrooxidation process for the treatment of soluble coffee effluent: Optimization of COD degradation and operation time analysis.

    PubMed

    Ibarra-Taquez, Harold N; GilPavas, Edison; Blatchley, Ernest R; Gómez-García, Miguel-Ángel; Dobrosz-Gómez, Izabela

    2017-09-15

    Soluble coffee production generates wastewater containing complex mixtures of organic macromolecules. In this work, a sequential Electrocoagulation-Electrooxidation (EC-EO) process, using aluminum and graphite electrodes, was proposed as an alternative way for the treatment of soluble coffee effluent. Process operational parameters were optimized, achieving total decolorization, as well as 74% and 63.5% of COD and TOC removal, respectively. The integrated EC-EO process yielded a highly oxidized (AOS = 1.629) and biocompatible (BOD 5 /COD ≈ 0.6) effluent. The Molecular Weight Distribution (MWD) analysis showed that during the EC-EO process, EC effectively decomposed contaminants with molecular weight in the range of 10-30 kDa. In contrast, EO was quite efficient in mineralization of contaminants with molecular weight higher than 30 kDa. A kinetic analysis allowed determination of the time required to meet Colombian permissible discharge limits. Finally, a comprehensive operational cost analysis was performed. The integrated EC-EO process was demonstrated as an efficient alternative for the treatment of industrial effluents resulting from soluble coffee production. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Optimization of electrocoagulation process to treat grey wastewater in batch mode using response surface methodology

    PubMed Central

    2014-01-01

    Background Discharge of grey wastewater into the ecological system causes the negative impact effect on receiving water bodies. Methods In this present study, electrocoagulation process (EC) was investigated to treat grey wastewater under different operating conditions such as initial pH (4–8), current density (10–30 mA/cm2), electrode distance (4–6 cm) and electrolysis time (5–25 min) by using stainless steel (SS) anode in batch mode. Four factors with five levels Box-Behnken response surface design (BBD) was employed to optimize and investigate the effect of process variables on the responses such as total solids (TS), chemical oxygen demand (COD) and fecal coliform (FC) removal. Results The process variables showed significant effect on the electrocoagulation treatment process. The results were analyzed by Pareto analysis of variance (ANOVA) and second order polynomial models were developed in order to study the electrocoagulation process statistically. The optimal operating conditions were found to be: initial pH of 7, current density of 20 mA/cm2, electrode distance of 5 cm and electrolysis time of 20 min. Conclusion These results indicated that EC process can be scale up in large scale level to treat grey wastewater with high removal efficiency of TS, COD and FC. PMID:24410752

  12. A randomized controlled trial of electrocoagulation-enabled biopsy versus conventional biopsy in the diagnosis of endobronchial lesions.

    PubMed

    Khan, Ajmal; Aggarwal, Ashutosh N; Agarwal, Ritesh; Bal, Amanjit; Gupta, Dheeraj

    2011-01-01

    Although electrocoagulation at time of endobronchial biopsy can potentially reduce procedure-related bleeding during fiberoptic bronchoscopy (FOB), it can also impair quality of tissue specimen; credible data for either are lacking. To evaluate the impact of hot biopsy on the quality of tissue samples and to quantify the amount of procedure-related bleeding during endobronchial biopsy. In this single-center, prospective, single-blind, randomized controlled study we included adult patients referred for FOB and having endobronchial lesions. Patients were randomized to bronchial biopsy using an electrocoagulation-enabled biopsy forceps, with (EC+ group) or without (EC- group) application of electrocoagulation current (40 W for 10 s in a monopolar mode). Procedure-related bleeding was semi-quantified by observer description, as well as through a visual analogue scale. Overall quality of biopsy specimen and tissue damage were assessed and graded by a pulmonary pathologist blinded to FOB details. 160 patients were randomized to endobronchial biopsy with (n = 81) or without (n = 79) the application of electrocoagulation. There were no severe bleeding episodes in either group, and severity of bleeding in the EC+ and EC- groups was similar (median visual analogue scale scores of 14 and 16, respectively). Histopathological diagnosis was similar in the EC+ and EC- groups (77.8% and 82.3%, respectively). There was no significant difference in tissue quality between the two groups. Use of electrocoagulation-enabled endobronchial biopsy does not alter specimen quality and does not result in any significant reduction in procedure-related bleeding. Copyright © 2010 S. Karger AG, Basel.

  13. Influences of operational parameters on phosphorus removal in batch and continuous electrocoagulation process performance.

    PubMed

    Nguyen, Dinh Duc; Yoon, Yong Soo; Bui, Xuan Thanh; Kim, Sung Su; Chang, Soon Woong; Guo, Wenshan; Ngo, Huu Hao

    2017-11-01

    Performance of an electrocoagulation (EC) process in batch and continuous operating modes was thoroughly investigated and evaluated for enhancing wastewater phosphorus removal under various operating conditions, individually or combined with initial phosphorus concentration, wastewater conductivity, current density, and electrolysis times. The results revealed excellent phosphorus removal (72.7-100%) for both processes within 3-6 min of electrolysis, with relatively low energy requirements, i.e., less than 0.5 kWh/m 3 for treated wastewater. However, the removal efficiency of phosphorus in the continuous EC operation mode was better than that in batch mode within the scope of the study. Additionally, the rate and efficiency of phosphorus removal strongly depended on operational parameters, including wastewater conductivity, initial phosphorus concentration, current density, and electrolysis time. Based on experimental data, statistical model verification of the response surface methodology (RSM) (multiple factor optimization) was also established to provide further insights and accurately describe the interactive relationship between the process variables, thus optimizing the EC process performance. The EC process using iron electrodes is promising for improving wastewater phosphorus removal efficiency, and RSM can be a sustainable tool for predicting the performance of the EC process and explaining the influence of the process variables.

  14. Hybrid process, electrocoagulation-biofiltration for landfill leachate treatment.

    PubMed

    Dia, Oumar; Drogui, Patrick; Buelna, Gerardo; Dubé, Rino

    2018-05-01

    Landfill leachates are known for their high and complex composition of organic, inorganic and microbial pollutants. As a result, it is quite challenging to treat these effluents by using only one treatment process. A combining approach is generally required to treat efficiently these wastewaters and comply with the discharge standards. In this present study, electrocoagulation (EC) and biofiltration (BF) processes were sequentially used to treat landfill leachate. EC process has been able to remove 37 ± 2% of the initial total COD. A fractionation of organic compounds showed that EC was particularly efficient to remove insoluble COD and humic acids. In addition, other pollutants such as turbidity, true color, Zn and phosphorus were significantly reduced by EC with 82 ± 2.7%, 60 ± 13%, 95 ± 2.6% and 82 ± 5.5% of removal respectively. The subsequent treatment by BF process led to completely removal of ammonia pollution (>99% of NH 4 removal) and a partial removal of dissolved organic compounds (42 ± 7% of COD removal). The hybrid process EC/BF could form the basis of a process capable of removing organic and inorganic pollutants from many refractory wastewaters (mature landfill leachates, industrial and municipal wastewaters). Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Electrocoagulation of palm oil mill effluent as wastewater treatment and hydrogen production using electrode aluminum.

    PubMed

    Nasution, M Ansori; Yaakob, Z; Ali, Ehsan; Tasirin, S M; Abdullah, S R S

    2011-01-01

    Palm oil mill effluent (POME) is highly polluting wastewater generated from the palm oil milling process. Palm oil mill effluent was used as an electrolyte without any additive or pretreatment to perform electrocoagulation (EC) using electricity (direct current) ranging from 2 to 4 volts in the presence of aluminum electrodes with a reactor volume of 20 L. The production of hydrogen gas, removal of chemical oxygen demand (COD), and turbidity as a result of electrocoagulation of POME were determined. The results show that EC can reduce the COD and turbidity of POME by 57 and 62%, respectively, in addition to the 42% hydrogen production. Hydrogen production was also helpful to remove the lighter suspended solids toward the surface. The production of Al(OH)XHO at the aluminum electrode (anode) was responsible for the flocculation-coagulation process of suspended solids followed by sedimentation under gravity. The production of hydrogen gas from POME during EC was also compared with hydrogen gas production by electrolysis of tap water at pH 4 and tap water without pH adjustment under the same conditions. The main advantage of this study is to produce hydrogen gas while treating POME with EC to reduce COD and turbidity effectively. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  16. Can electrocoagulation process be an appropriate technology for phosphorus removal from municipal wastewater?

    PubMed

    Nguyen, D Duc; Ngo, H Hao; Guo, W; Nguyen, T Thanh; Chang, Soon W; Jang, A; Yoon, Yong S

    2016-09-01

    This paper evaluated a novel pilot scale electrocoagulation (EC) system for improving total phosphorus (TP) removal from municipal wastewater. This EC system was operated in continuous and batch operating mode under differing conditions (e.g. flow rate, initial concentration, electrolysis time, conductivity, voltage) to evaluate correlative phosphorus and electrical energy consumption. The results demonstrated that the EC system could effectively remove phosphorus to meet current stringent discharge standards of less than 0.2mg/L within 2 to 5min. This target was achieved in all ranges of initial TP concentrations studied. It was also found that an increase in conductivity of solution, voltages, or electrolysis time, correlated with improved TP removal efficiency and reduced specific energy consumption. Based on these results, some key economic considerations, such as operating costs, cost-effectiveness, product manufacturing feasibility, facility design and retrofitting, and program implementation are also discussed. This EC process can conclusively be highly efficient in a relatively simple, easily managed, and cost-effective for wastewater treatment system. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Integrated pretreatment and desalination by electrocoagulation (EC)-ion concentration polarization (ICP) hybrid.

    PubMed

    Choi, Siwon; Kim, Bumjoo; Han, Jongyoon

    2017-06-13

    Conventional water treatment process is composed of multiple stages, including desalination (salt removal) and pre/post-treatment of desalination to remove particles, chemicals, and other potential foulants for desalination. In this work, we developed a microfluidic proof-of-concept for a single device water treatment system, which removes both salt ions and non-salt contaminants. Our system combines electrocoagulation (EC), a versatile contaminant removal process, and ion concentration polarization (ICP) desalination, which is an electromembrane desalination process. We demonstrated a continuous EC-ICP operation that removed >95% of suspended solids and reduced the salinity from brackish range (20 mM NaCl) to a potable level (<8.6 mM NaCl). We also demonstrated that our system is flexible in terms of the type and concentration of contaminants it can handle. Combining two different electrochemical processes into a single system, we can reduce unnecessary voltage drop by having a shared anode, and achieve both seamless integration and energy efficient operation. Our system will find applications as a small-scale water treatment system, if properly scaled up in the future.

  18. Adsorption treatment of oxide chemical mechanical polishing wastewater from a semiconductor manufacturing plant by electrocoagulation.

    PubMed

    Chou, Wei-Lung; Wang, Chih-Ta; Chang, Wen-Chun; Chang, Shih-Yu

    2010-08-15

    In this study, metal hydroxides generated during electrocoagulation (EC) were used to remove the chemical oxygen demand (COD) of oxide chemical mechanical polishing (oxide-CMP) wastewater from a semiconductor manufacturing plant by EC. Adsorption studies were conducted in a batch system for various current densities and temperatures. The COD concentration in the oxide-CMP wastewater was effectively removed and decreased by more than 90%, resulting in a final wastewater COD concentration that was below the Taiwan discharge standard (100 mg L(-1)). Since the processed wastewater quality exceeded the direct discharge standard, the effluent could be considered for reuse. The adsorption kinetic studies showed that the EC process was best described using the pseudo-second-order kinetic model at the various current densities and temperatures. The experimental data were also tested against different adsorption isotherm models to describe the EC process. The Freundlich adsorption isotherm model predictions matched satisfactorily with the experimental observations. Thermodynamic parameters, including the Gibbs free energy, enthalpy, and entropy, indicated that the COD adsorption of oxide-CMP wastewater on metal hydroxides was feasible, spontaneous and endothermic in the temperature range of 288-318 K. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Organic pollutant removal from edible oil process wastewater using electrocoagulation

    NASA Astrophysics Data System (ADS)

    Sharma, S.; Can, O. T.; Hammed, M.; Nawarathna, D.; Simsek, H.

    2018-03-01

    Wastewaters generated from vegetable oil industries contain a high concentration of organic pollutants that are detrimental to the aquatic ecosystem. Electrochemical processes are gaining importance in the treatment of inorganic and resistant organic pollutants in wastewaters. In this study, electrocoagulation (EC) was applied to remove organic pollutants and oil and grease from canola oil wastewater using aluminum (Al) and iron (Fe) electrodes. The application of EC in the wastewater achieved more than 80% removal of organic carbon and nearly 100% removal of suspended solids (SS). The effectiveness of EC is influenced mainly by current density, pH, electrolyte (NaCl), electrode contact time and electrode type. It was observed that Al electrode combination yielded better removal at a lesser time compared to that of Fe electrodes. However, varying current densities had its significance in terms of coagulation time only. Increase in current density achieved decrease in coagulation time. Both Al and Fe could remove between 52-59% of oil and grease from canola oil wastewater

  20. Influence of softening sequencing on electrocoagulation treatment of produced water.

    PubMed

    Esmaeilirad, Nasim; Carlson, Ken; Omur Ozbek, Pinar

    2015-01-01

    Electrocoagulation has been used to remove solids and some metals from both water and wastewater sources for decades. Additionally, chemical softening is commonly employed in water treatment systems to remove hardness. This paper assesses the combination and sequence of softening and EC methods to treat hydraulic fracturing flowback and produced water from shale oil and gas operations. EC is one of the available technologies to treat produced water for reuse in frac fluids, eliminating not only the need to transport more water but also the costs of providing fresh water. In this paper, the influence of chemical softening on EC was studied. In the softening process, pH was raised to 9.5 and 10.2 before and after EC, respectively. Softening, when practiced before EC was more effective for removing turbidity with samples from wells older than one month (99% versus 88%). However, neither method was successful in treating samples collected from early flowback (1-day and 2-day samples), likely due to the high concentration of organic matter. For total organic carbon, hardness, Ba, Sr, and B removal, application of softening before EC appeared to be the most efficient approach, likely due to the formation of solids before the coagulation process. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Modelling of fluoride removal via batch monopolar electrocoagulation process using aluminium electrodes

    NASA Astrophysics Data System (ADS)

    Amri, N.; Hashim, M. I.; Ismail, N.; Rohman, F. S.; Bashah, N. A. A.

    2017-09-01

    Electrocoagulation (EC) is a promising technology that extensively used to remove fluoride ions efficiently from industrial wastewater. However, it has received very little consideration and understanding on mechanism and factors that affecting the fluoride removal process. In order to determine the efficiency of fluoride removal in EC process, the effect of operating parameters such as voltage and electrolysis time were investigated in this study. A batch experiment with monopolar aluminium electrodes was conducted to identify the model of fluoride removal using empirical model equation. The EC process was investigated using several parameters which include voltage (3 - 12 V) and electrolysis time (0 - 60 minutes) at a constant initial fluoride concentration of 25 mg/L. The result shows that the fluoride removal efficiency increased steadily with increasing voltage and electrolysis time. The best fluoride removal efficiency was obtained with 94.8 % removal at 25 mg/L initial fluoride concentration, voltage of 12 V and 60 minutes electrolysis time. The results indicated that the rate constant, k and number of order, n decreased as the voltage increased. The rate of fluoride removal model was developed based on the empirical model equation using the correlation of k and n. Overall, the result showed that EC process can be considered as a potential alternative technology for fluoride removal in wastewater.

  2. Electrocoagulation efficiency of the tannery effluent treatment using aluminium electrodes.

    PubMed

    Espinoza-Quiñones, Fernando R; Fornari, Marilda M T; Módenes, Aparecido N; Palácio, Soraya M; Trigueros, Daniela E G; Borba, Fernando H; Kroumov, Alexander D

    2009-01-01

    An electro-coagulation laboratory scale system using aluminium plates electrodes was studied for the removal of organic and inorganic pollutants as a by-product from leather finishing industrial process. A fractional factorial 2(3) experimental design was applied in order to obtain optimal values of the system state variables. The electro-coagulation (EC) process efficiency was based on the chemical oxygen demand (COD), turbidity, total suspended solid, total fixed solid, total volatile solid, and chemical element concentration values. Analysis of variance (ANOVA) for final pH, total fixed solid (TFS), turbidity and Ca concentration have confirmed the predicted models by the experimental design within a 95% confidence level. The reactor working conditions close to real effluent pH (7.6) and electrolysis time in the range 30-45 min were enough to achieve the cost effective reduction factors of organic and inorganic pollutants' concentrations. An appreciable improvement in COD removal efficiency was obtained for electro-coagulation treatment. Finally, the technical-economical analysis results have clearly shown that the electro-coagulation method is very promising for industrial application.

  3. Combined electrocoagulation and electro-oxidation of industrial textile wastewater treatment in a continuous multi-stage reactor.

    PubMed

    GilPavas, Edison; Arbeláez-Castaño, Paula; Medina, José; Acosta, Diego A

    2017-11-01

    A combined electrocoagulation (EC) and electrochemical oxidation (EO) industrial textile wastewater treatment potential is evaluated in this work. A fractional factorial design of experiment showed that EC current density, followed by pH, were the most significant factors. Conductivity and number of electrooxidation cells did not affect chemical oxygen demand degradation (DCOD). Aluminum and iron anodes performed similarly as sacrificial anodes. Current density, pH and conductivity were chosen for a Box-Behnken design of experiment to determine optimal conditions to achieve a high DCOD minimizing operating cost (OC). The optimum to achieve a 70% DCOD with an OC of USD 1.47/m 3 was: pH of 4, a conductivity of 3.7 mS/cm and a current density of 4.1 mA/cm 2 . This study also shows the applicability of a combined EC/EO treatment process of a real complex industrial wastewater.

  4. Low-energy hydraulic fracturing wastewater treatment via AC powered electrocoagulation with biochar.

    PubMed

    Lobo, Fernanda Leite; Wang, Heming; Huggins, Tyler; Rosenblum, James; Linden, Karl G; Ren, Zhiyong Jason

    2016-05-15

    Produced and flowback waters are the largest byproducts associated with unconventional oil and gas exploration and production. Sustainable and low cost technologies are needed to treat and reuse this wastewater to avoid the environmental problems associated with current management practices (i.e., deep well injection). This study presents a new process to integrate AC-powered electrocoagulation (EC) with granular biochar to dramatically reduce energy use and electrode passivation while achieving high treatment efficiency. Results show achieving a 99% turbidity and TSS removal for the AC-EC-biochar system only used 0.079 kWh/m(3) or 0.15 kWh/kg TSS, which is 70% lower than traditional DC-EC systems and orders of magnitude lower than previous studies. The amount of biochar added positively correlates with energy saving, and further studies are needed to improve organic carbon and salt removal through system integration. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Comparison of phthalic acid removal from aqueous solution by electrochemical methods: Optimization, kinetic and sludge study.

    PubMed

    Sandhwar, Vishal Kumar; Prasad, Basheshwar

    2017-12-01

    In this work, comparative study between electrochemical processes such as electrocoagulation (EC), peroxi-coagulation (PC) and peroxi-electrocoagulation (PEC) was performed for the removal of phthalic acid (PA) and chemical oxygen demand (COD) from aqueous medium. Initially, acid treatment was studied at various pH (1-3) and temperature (10-55 °C). Subsequently, the supernatant was re-treated by electrochemical processes such as EC, PC and PEC separately. Independent parameters viz. pH, current density (CD), electrolyte concentration (m), electrode gap (g), H 2 O 2 concentration and electrolysis time (t) were optimized by Central Composite Design (CCD) for these electrochemical processes. All three processes were compared based on removal, energy consumption, kinetic analysis, operating cost and sludge characteristics. In this study, PEC process was found more efficient among EC, PC and PEC processes in order to get maximum removal, minimum energy consumption and minimum operating cost. Maximum removal of PA- 68.21%, 74.36%, 82.25% & COD- 64.79%, 68.15%, 75.21% with energy consumption - 120.95, 97.51, 65.68 (kWh/kg COD removed) were attained through EC, PC and PEC processes respectively at their corresponding optimum conditions. Results indicated that PA and COD removals are in order of PEC > PC > EC under optimum conditions. First order kinetic model was found able to describe the degradation kinetics and provided best correlation for the removal rate within the acceptable error range. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Performance and mechanisms for the removal of phthalates and pharmaceuticals from aqueous solution by graphene-containing ceramic composite tubular membrane coupled with the simultaneous electrocoagulation and electrofiltration process.

    PubMed

    Yang, Gordon C C; Chen, Ying-Chun; Yang, Hao-Xuan; Yen, Chia-Heng

    2016-07-01

    In this study, commonly detected emerging contaminants (ECs) in water, including di-n-butyl phthalate (DnBP), di(2-ethylhexyl) phthalate (DEHP), cephalexin (CLX), sulfamethoxazole (SMX) and caffeine (CAF), were selected as the target contaminants. A lab-prepared graphene-containing ceramic composite tubular membrane (TGCCM) coupled with the simultaneous electrocoagulation and electrofiltration process (EC/EF) in crossflow filtration mode was used to remove target contaminants in model solution. Meanwhile, a comparison of the removal efficiency was made among various tubular composite membranes reported, including carbon fibers/carbon/alumina composite tubular membrane (TCCACM), titania/alumina composite tubular membrane (TTACM) and alumina tubular membrane (TAM). The results of this study showed that the removal efficiencies for DnBP and DEHP were 99%, whereas 32-97% for cephalexin (CLX), sulfamethoxazole (SMX) and caffeine (CAF). In this work the mechanisms involved in removing target ECs were proposed and their roles in removing various ECs were also discussed. Further, two actual municipal wastewaters were treated to evaluate the applicability of the aforementioned treatment technology (i.e., TGCCM coupled with EC/EF) to various aqueous solutions in the real world. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Decolorization of C.I. Acid Blue 9 solution by UV/Nano-TiO(2), Fenton, Fenton-like, electro-Fenton and electrocoagulation processes: a comparative study.

    PubMed

    Khataee, A R; Vatanpour, V; Amani Ghadim, A R

    2009-01-30

    This study makes a comparison between UV/Nano-TiO(2), Fenton, Fenton-like, electro-Fenton (EF) and electrocoagulation (EC) treatment methods to investigate the removal of C.I. Acid Blue 9 (AB9), which was chosen as the model organic contaminant. Results indicated that the decolorization efficiency was in order of Fenton>EC>UV/Nano-TiO(2)>Fenton-like>EF. Desired concentrations of Fe(2+) and H(2)O(2) for the abatement of AB9 in the Fenton-based processes were found to be 10(-4)M and 2 x 10(-3) M, respectively. In the case of UV/Nano-TiO(2) process, we have studied the influence of the basic photocatalytic parameters such as the irradiation time, pH of the solution and amount of TiO(2) nanoparticles on the photocatalytic decolorization efficiency of AB9. Accordingly, it could be stated that the complete removal of color, after selecting desired operational parameters could be achieved in a relatively short time, about 25 min. Our results also revealed that the most effective decomposition of AB9 was observed with 150 mg/l of TiO(2) nanoparticles in acidic condition. The effect of operational parameters including current density, initial pH and time of electrolysis were studied in electrocoagulation process. The results indicated that for a solution of 20 mg/l AB9, almost 98% color were removed, when the pH was about 6, the time of electrolysis was 8 min and the current density was approximately 25 A/m(2) in electrocoagulation process.

  8. Electrocoagulation: Simply a Phase Separation Technology? The Case of Bronopol Compared to Its Treatment by EAOPs.

    PubMed

    Bocos, Elvira; Brillas, Enric; Sanromán, M Ángeles; Sirés, Ignasi

    2016-07-19

    Electrocoagulation (EC) has long been considered a phase separation process, well suited for industrial wastewater treatment since it causes a quick, drastic decay of organic matter content. This research demonstrates that EC also behaves, at least for some molecules like the industrial preservative bronopol, as an effective transformation technology able to yield several breakdown products. This finding has relevant environmental implications, pointing to EC as a greener process than described in literature. A thorough optimization of EC was performed with solutions of bronopol in a simulated water matrix, yielding the complete disappearance of the parent molecule within 20 min at 200 mA (∼20 mA/cm(2)), using Fe as the anode and cathode. A 25% of total organic carbon (TOC) abatement was attained as maximum, with bronopol being converted into bromonitromethane, bromochloromethane, formaldehyde and formic acid. N atoms were accumulated as NO3(-), whereas Br(-) was stable once released. This suggests that mediated oxidation by active chlorine, as well as by hydroxyl radicals resulting from its reaction with iron ions, is the main transformation mechanism. Aiming to enhance the mineralization, a sequential combination of EC with electro-Fenton (EF) as post-treatment process was proposed. EF with boron-doped diamond (BDD) anode ensured the gradual TOC removal under the action of (•)OH and BDD((•)OH), also transforming Br(-) into BrO3(-).

  9. Biodegradability and toxicity assessment of a real textile wastewater effluent treated by an optimized electrocoagulation process.

    PubMed

    Manenti, Diego R; Módenes, Aparecido N; Soares, Petrick A; Boaventura, Rui A R; Palácio, Soraya M; Borba, Fernando H; Espinoza-Quiñones, Fernando R; Bergamasco, Rosângela; Vilar, Vítor J P

    2015-01-01

    In this work, the application of an iron electrode-based electrocoagulation (EC) process on the treatment of a real textile wastewater (RTW) was investigated. In order to perform an efficient integration of the EC process with a biological oxidation one, an enhancement in the biodegradability and low toxicity of final compounds was sought. Optimal values of EC reactor operation parameters (pH, current density and electrolysis time) were achieved by applying a full factorial 3(3) experimental design. Biodegradability and toxicity assays were performed on treated RTW samples obtained at the optimal values of: pH of the solution (7.0), current density (142.9 A m(-2)) and different electrolysis times. As response variables for the biodegradability and toxicity assessment, the Zahn-Wellens test (Dt), the ratio values of dissolved organic carbon (DOC) relative to low-molecular-weight carboxylates anions (LMCA) and lethal concentration 50 (LC50) were used. According to the Dt, the DOC/LMCA ratio and LC50, an electrolysis time of 15 min along with the optimal values of pH and current density were suggested as suitable for a next stage of treatment based on a biological oxidation process.

  10. Optimization of electrocoagulation process for the treatment of landfill leachate

    NASA Astrophysics Data System (ADS)

    Huda, N.; Raman, A. A.; Ramesh, S.

    2017-06-01

    The main problem of landfill leachate is its diverse composition comprising of persistent organic pollutants (POPs) which must be removed before being discharge into the environment. In this study, the treatment of leachate using electrocoagulation (EC) was investigated. Iron was used as both the anode and cathode. Response surface methodology was used for experimental design and to study the effects of operational parameters. Central Composite Design was used to study the effects of initial pH, inter-electrode distance, and electrolyte concentration on color, and COD removals. The process could remove up to 84 % color and 49.5 % COD. The experimental data was fitted onto second order polynomial equations. All three factors were found to be significantly affect the color removal. On the other hand, electrolyte concentration was the most significant parameter affecting the COD removal. Numerical optimization was conducted to obtain the optimum process performance. Further work will be conducted towards integrating EC with other wastewater treatment processes such as electro-Fenton.

  11. Arsenic removal via electrocoagulation from heavy metal contaminated groundwater in La Comarca Lagunera México.

    PubMed

    Parga, Jose R; Cocke, David L; Valenzuela, Jesus L; Gomes, Jewel A; Kesmez, Mehmet; Irwin, George; Moreno, Hector; Weir, Michael

    2005-09-30

    Arsenic contamination is an enormous worldwide problem. A large number of people dwelling in Comarca Lagunera, situated in the central part of northern México, use well water with arsenic in excess of the water standard regulated by the Secretary of Environment and Natural Resources of México (SEMARNAT), to be suitable for human health. Individuals with lifetime exposure to arsenic develop the classic symptoms of arsenic poisoning. Among several options available for removal of arsenic from well water, electrocoagulation (EC) is a very promising electrochemical treatment technique that does not require the addition of chemicals or regeneration. First, this study will provide an introduction to the fundamental concepts of the EC method. In this study, powder X-ray diffraction, scanning electron microscopy, transmission Mössbauer spectroscopy and Fourier transform infrared spectroscopy were used to characterize the solid products formed at iron electrodes during the EC process. The results suggest that magnetite particles and amorphous iron oxyhydroxides present in the EC products remove arsenic(III) and arsenic(V) with an efficiency of more than 99% from groundwater in a field pilot scale study.

  12. Purification and detoxification of petroleum refinery wastewater by electrocoagulation process.

    PubMed

    Gousmi, N; Sahmi, A; Li, H Z; Poncin, S; Djebbar, R; Bensadok, K

    2016-09-01

    The treatment of synthetic oily wastewater having the characteristics of a typical petroleum refinery wastewater (PRW) by electrocoagulation (EC) using iron and aluminum electrodes was conducted in an electrolytic reactor equipped with fluid recirculation. During the treatment, the emulsion stability was followed by the measurement of Zeta potential and particle sizes. Effects of some operating conditions such as electrodes material, current density and electrolysis time on removal efficiencies of turbidity, and chemical oxygen demand (COD) were investigated in detail. The PRW purification by the EC process was found to be the most effective using aluminum as the anode and cathode, current density of 60 A/m(2) and 30 min of electrolysis time. Under these conditions, the process efficiencies were 83.52% and 99.94%, respectively, for COD and turbidity removals which correspond to final values of 96 mg O2/L and 0.5 NTU. A moderate energy consumption (0.341 kWh) was needed to treat 1 m(3) of PRW. Besides, the ecotoxicity test proved that toxic substances presented in the PRW, and those inhibiting the germination growth of whet, were eliminated by the EC technique.

  13. Aluminum electrocoagulation as pretreatment during microfiltration of surface water containing NOM: A review of fouling, NOM, DBP, and virus control.

    PubMed

    Chellam, Shankararaman; Sari, Mutiara Ayu

    2016-03-05

    Electrocoagulation (EC) is the intentional corrosion of sacrificial anodes (typically aluminum or iron) by passing electricity to release metal-ion coagulant species and destabilize a wide range of suspended, dissolved, and macromolecular contaminants. It can be integrated ahead of microfiltration (MF) to effectively control turbidity, microorganisms, and disinfection by-products (DBPs) and simultaneously maintain a high MF specific flux. This manuscript summarizes the current knowledge on MF pretreatment by aluminum EC particularly focusing on mechanisms of (i) electrocoagulant dosing, (ii) (bio)colloid destabilization, (iii) fouling reductions, and (iv) enhanced removal of viruses, natural organic matter (NOM), and DBP precursors. Electrolysis efficiently removes hydrophobic NOM, viruses, and siliceous foulants. Aluminum effectively electrocoagulates viruses by physically encapsulating them in flocs, neutralizing their surface charge and reducing electrostatic repulsion, and increasing hydrophobic interactions between any sorbed NOM and free viruses. New results included herein demonstrate that EC achieves DBP control by removing NOM, reducing chlorine-reactivity of remaining NOM, and inducing a slight shift toward more brominated trihalomethanes and haloacetic acids. EC reduces MF fouling by forming large flocs that tend to deposit on the membrane surface, i.e. decrease pore penetration and forming more permeable cakes and by reducing foulant mass in case of significant floc-flotation. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Soft drink wastewater treatment by electrocoagulation-electrooxidation processes.

    PubMed

    Linares Hernández, Ivonne; Barrera Díaz, Carlos; Valdés Cerecero, Mario; Almazán Sánchez, Perla Tatiana; Castañeda Juárez, Monserrat; Lugo Lugo, Violeta

    2017-02-01

    The aim of this work was to implement a coupled system, a monopolar Electrocoagulation (EC)-Electrooxidation (EO) processes, for the treatment of soft drink wastewater. For the EC test, Cu-Cu, anode-cathode were used at current densities of 17, 51 and 68 mA cm -2 . Only 37.67% of chemical oxygen demand (COD) and 27% of total organic carbon (TOC) were removed at 20 min with an optimum pH of 8, this low efficiency can be associated with the high concentration of inorganic ions which inhibit the oxidation of organic matter due to their complexation with copper ions. Later EO treatment was performed with boron-doped diamond-Cu electrodes and a current density of 30 Am -2 . The coupled EC-EO system was efficient to reduce organic pollutants from initial values of 1875 mg L -1 TOC and 4300 mg L -1 COD, the removal efficiencies were 75% and 85%, respectively. Electric energy consumption to degrade a kilogram of a pollutant in the soft drink wastewater using EC was 3.19 kWh kg -1 TOC and 6.66 kWh kg -1 COD. It was concluded that the coupled system EC-EO was effective for the soft drink wastewater treatment, reducing operating costs and residence time, and allowing its reuse in indirect contact with humans, thus contributing to the sustainable reuse as an effluent of industrial wastewater.

  15. Removal of suspended solids and turbidity from marble processing wastewaters by electrocoagulation: comparison of electrode materials and electrode connection systems.

    PubMed

    Solak, Murat; Kiliç, Mehmet; Hüseyin, Yazici; Sencan, Aziz

    2009-12-15

    In this study, removal of suspended solids (SS) and turbidity from marble processing wastewaters by electrocoagulation (EC) process were investigated by using aluminium (Al) and iron (Fe) electrodes which were run in serial and parallel connection systems. To remove these pollutants from the marble processing wastewater, an EC reactor including monopolar electrodes (Al/Fe) in parallel and serial connection system, was utilized. Optimization of differential operation parameters such as pH, current density, and electrolysis time on SS and turbidity removal were determined in this way. EC process with monopolar Al electrodes in parallel and serial connections carried out at the optimum conditions where the pH value was 9, current density was approximately 15 A/m(2), and electrolysis time was 2 min resulted in 100% SS removal. Removal efficiencies of EC process for SS with monopolar Fe electrodes in parallel and serial connection were found to be 99.86% and 99.94%, respectively. Optimum parameters for monopolar Fe electrodes in both of the connection types were found to be for pH value as 8, for electrolysis time as 2 min. The optimum current density value for Fe electrodes used in serial and parallel connections was also obtained at 10 and 20 A/m(2), respectively. Based on the results obtained, it was found that EC process running with each type of the electrodes and the connections was highly effective for the removal of SS and turbidity from marble processing wastewaters, and that operating costs with monopolar Al electrodes in parallel connection were the cheapest than that of the serial connection and all the configurations for Fe electrode.

  16. Electrocoagulation pretreatment of wet-spun acrylic fibers manufacturing wastewater to improve its biodegradability.

    PubMed

    Gong, Chenhao; Zhang, Zhongguo; Li, Haitao; Li, Duo; Wu, Baichun; Sun, Yuwei; Cheng, Yanjun

    2014-06-15

    The electrocoagulation (EC) process was used to pretreat wastewater from the manufacture of wet-spun acrylic fibers, and the effects of varying the operating parameters, including the electrode area/wastewater volume (A/V) ratio, current density, interelectrode distance and pH, on the EC treatment process were investigated. About 44% of the total organic carbon was removed using the optimal conditions in a 100 min procedure. The optimal conditions were a current density of 35.7 mA cm(-2), an A/V ratio of 0.28 cm(-1), a pH of 5, and an interelectrode distance of 0.8 cm. The biodegradability of the contaminants in the treated water was improved by the EC treatment (using the optimal conditions), increasing the five-day biological oxygen demand/chemical oxygen demand ratio to 0.35, which could improve the effectiveness of subsequent biological treatments. The improvement in the biodegradability of the contaminants in the wastewater was attributed to the removal and degradation of aromatic organic compounds, straight-chain paraffins, and other organic compounds, which we identified using gas chromatography-mass spectrometry and Fourier transform infrared spectroscopy. The EC process was proven to be an effective alternative pretreatment for wastewater from the manufacture of wet-spun acrylic fibers, prior to biological treatments. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Comparative performance of anodic oxidation and electrocoagulation as clean processes for electrocatalytic degradation of diazo dye Acid Brown 14 in aqueous medium.

    PubMed

    Bassyouni, D G; Hamad, H A; El-Ashtoukhy, E-S Z; Amin, N K; El-Latif, M M Abd

    2017-08-05

    In this study, a laboratory scale for the treatment of a recalcitrant and toxic synthetic wastewater containing diazo dye, acid brown 14 (AB-14) has been comparatively performed by two electro-catalytic treatment processes, namely anodic oxidation (AO) and electrocoagulation (EC) using a new batch electrochemical cell. Additionally, the influence of several operating parameters such as; current density (j), initial dye concentration (C o ), NaCl concentration (C N ), and pH on the color removal efficiency and chemical oxygen demand (COD) are evaluated. The powerful capability of the AO and EC of AB-14 which related to the mechanistic reaction pathway is shown. The poor degradation is ascribed to higher C o and pH, while the enhancement of j and C N is responsible for better degradation of AB-14 dye. The results indicate that the EC is more effective than AO under the same operational condition. A kinetic model is developed for evaluation of the pseudo-first-order-rate constant (k app ) as a function of various operational parameters. The results emphasize the high efficiency of AO and EC and the clean processes which are hopeful alternative for the treatment of the large volume wastewater of the textile industry. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Arsenic Removal and Its Chemistry in Batch Electrocoagulation Studies.

    PubMed

    Sharma, Anshul; Adapureddy, Sri Malini; Goel, Sudha

    2014-04-01

    The aim of this study was to evaluate the impact of different oxidizing agents like light, aeration (by mixing) and electrocoagulation (EC) on the oxidation of As (III) and its subsequent removal in an EC batch reactor. Arsenic solutions prepared using distilled water and groundwater were evaluated. Optimum pH and the effect of varying initial pH on As removal efficiency were also evaluated. MaximumAs (III) removal efficiency with EC, light and aeration was 97% from distilled water and 71% from groundwater. Other results show that EC alone resulted in 90% As removal efficiency in the absence of light and mixing from distilled water and 53.6% from groundwater. Removal with light and mixing but without EC resulted in only 26% As removal from distilled water and 29% from groundwater proving that electro-oxidation and coagulation were more effective in removing arsenic compared to the other oxidizing agents examined. Initial pH was varied from 5 to 10 in distilled water and from 3 to 12 in groundwater for evaluating arsenic removal efficiency by EC. The optimum initial pH for arsenic removal was 7 for distilled water and groundwater. For all initial pHs tested between 5 and 10 in distilled water, the final pH ranged between 7 and 8 indicating that the EC process tends towards near neutral pH under the conditions examined in this study.

  19. Physico-chemical treatment of liquid waste on an industrial plant for electrocoagulation.

    PubMed

    Mlakar, Matej; Levstek, Marjetka; Stražar, Marjeta

    2017-10-01

    Wastewater from washing, oil separators, the metal processing and detergent industries, was tested and treated for treatment of different types of liquid waste at industrial level at Domžale-Kamnik Wastewater Treatment Plant (WWTP). The effect of implementing the electrocoagulation (EC) and flotation processes, respectively, is analysed and includes the duration of the EC implementation, voltage, number of electrodes, and chemical addition, as well as the pH effect and conductivity. The tests were performed not only on various types of liquid waste, but also on different mixtures of liquid waste. Laboratory analysis of the samples before and after EC have shown an effective reduction not only in organic loads in accordance with the COD (chemical oxygen demand) parameter, but also in mineral oil content, toxic metal concentration, and surfactants. The COD in liquid waste from the detergent industry was reduced by 73% and the content of surfactants by 64%. In liquid waste from the metal processing industry, the COD decreased by up to 95%, while the content of toxic metals decreased from 59 to 99%. Similar phenomena were shown in liquid waste from oil separators, where the COD was reduced to 33% and the concentration of mineral oils by 99%. Some of the liquid wastes were mixed together in the ratio 1:1, thus allowing testing of the operation of EC technology in heterogeneous liquid waste, where the final result proved to be effective cleaning as well. After treatment in the process of EC, the limit values of the treated water proved appropriate for discharge into the sewerage system.

  20. Oil refinery wastewater treatment using coupled electrocoagulation and fixed film biological processes

    NASA Astrophysics Data System (ADS)

    Pérez, Laura S.; Rodriguez, Oscar M.; Reyna, Silvia; Sánchez-Salas, José Luis; Lozada, J. Daniel; Quiroz, Marco A.; Bandala, Erick R.

    2016-02-01

    Oil refinery wastewater was treated using a coupled treatment process including electrocoagulation (EC) and a fixed film aerobic bioreactor. Different variables were tested to identify the best conditions using this procedure. After EC, the effluent was treated in an aerobic biofilter. EC was capable to remove over 88% of the overall chemical oxygen demand (COD) in the wastewater under the best working conditions (6.5 V, 0.1 M NaCl, 4 electrodes without initial pH adjustment) with total petroleum hydrocarbon (TPH) removal slightly higher than 80%. Aluminum release from the electrodes to the wastewater was found an important factor for the EC efficiency and closely related with several operational factors. Application of EC allowed to increase the biodegradability of the sample from 0.015, rated as non-biodegradable, up to 0.5 widely considered as biodegradable. The effluent was further treated using an aerobic biofilter inoculated with a bacterial consortium including gram positive and gram negative strains and tested for COD and TPH removal from the EC treated effluent during 30 days. Cell count showed the typical bacteria growth starting at day three and increasing up to a maximum after eight days. After day eight, cell growth showed a plateau which agreed with the highest decrease on contaminant concentration. Final TPHs concentration was found about 600 mgL-1 after 30 days whereas COD concentration after biological treatment was as low as 933 mgL-1. The coupled EC-aerobic biofilter was capable to remove up to 98% of the total TPH amount and over 95% of the COD load in the oil refinery wastewater.

  1. Removal of nitrate and sulphate from biologically treated municipal wastewater by electrocoagulation

    NASA Astrophysics Data System (ADS)

    Sharma, Arun Kumar; Chopra, A. K.

    2017-06-01

    The present investigation observed the effect of current density ( j), electrocoagulation (EC) time, inter electrode distance, electrode area, initial pH and settling time on the removal of nitrate (NO3 -) and sulphate (SO4 2-) from biologically treated municipal wastewater (BTMW), and optimization of the operating conditions of the EC process. A glass chamber of two-liter volume was used for the experiments with DC power supply using two electrode plates of aluminum (Al-Al). The maximum removal of NO3 - (63.21 %) and SO4 2- (79.98 %) of BTMW was found with the optimum operating conditions: current density: 2.65 A/m2, EC time: 40 min, inter electrode distance: 0.5 cm, electrode area: 160 cm2, initial pH: 7.5 and settling time: 60 min. The EC brought down the concentration of NO3 - within desirable limit of the Bureau of Indian Standard (BIS)/WHO for drinking water. Under optimal operating conditions, the operating cost was found to be 1.01/m3 of water in terms of the electrode consumption (23.71 × 10-5 kg Al/m3) and energy consumption (101.76 kWh/m3).

  2. Reduction of nutrients, microbes, and personal care products in domestic wastewater by a benchtop electrocoagulation unit

    PubMed Central

    Symonds, E. M.; Cook, M. M.; McQuaig, S. M.; Ulrich, R. M.; Schenck, R. O.; Lukasik, J. O.; Van Vleet, E. S.; Breitbart, M.

    2015-01-01

    To preserve environmental and human health, improved treatment processes are needed to reduce nutrients, microbes, and emerging chemical contaminants from domestic wastewater prior to discharge into the environment. Electrocoagulation (EC) treatment is increasingly used to treat industrial wastewater; however, this technology has not yet been thoroughly assessed for its potential to reduce concentrations of nutrients, a variety of microbial surrogates, and personal care products found in domestic wastewater. This investigation's objective was to determine the efficiency of a benchtop EC unit with aluminum sacrificial electrodes to reduce concentrations of the aforementioned biological and chemical pollutants from raw and tertiary-treated domestic wastewater. EC treatment resulted in significant reductions (p < 0.05, α = 0.05) in phosphate, all microbial surrogates, and several personal care products from raw and tertiary-treated domestic wastewater. When wastewater was augmented with microbial surrogates representing bacterial, viral, and protozoan pathogens to measure the extent of reduction, EC treatment resulted in up to 7-log10 reduction of microbial surrogates. Future pilot and full-scale investigations are needed to optimize EC treatment for the following: reducing nitrogen species, personal care products, and energy consumption; elucidating the mechanisms behind microbial reductions; and performing life cycle analyses to determine the appropriateness of implementation. PMID:25797885

  3. Reduction of nutrients, microbes, and personal care products in domestic wastewater by a benchtop electrocoagulation unit.

    PubMed

    Symonds, E M; Cook, M M; McQuaig, S M; Ulrich, R M; Schenck, R O; Lukasik, J O; Van Vleet, E S; Breitbart, M

    2015-03-23

    To preserve environmental and human health, improved treatment processes are needed to reduce nutrients, microbes, and emerging chemical contaminants from domestic wastewater prior to discharge into the environment. Electrocoagulation (EC) treatment is increasingly used to treat industrial wastewater; however, this technology has not yet been thoroughly assessed for its potential to reduce concentrations of nutrients, a variety of microbial surrogates, and personal care products found in domestic wastewater. This investigation's objective was to determine the efficiency of a benchtop EC unit with aluminum sacrificial electrodes to reduce concentrations of the aforementioned biological and chemical pollutants from raw and tertiary-treated domestic wastewater. EC treatment resulted in significant reductions (p < 0.05, α = 0.05) in phosphate, all microbial surrogates, and several personal care products from raw and tertiary-treated domestic wastewater. When wastewater was augmented with microbial surrogates representing bacterial, viral, and protozoan pathogens to measure the extent of reduction, EC treatment resulted in up to 7-log10 reduction of microbial surrogates. Future pilot and full-scale investigations are needed to optimize EC treatment for the following: reducing nitrogen species, personal care products, and energy consumption; elucidating the mechanisms behind microbial reductions; and performing life cycle analyses to determine the appropriateness of implementation.

  4. Reduction of nutrients, microbes, and personal care products in domestic wastewater by a benchtop electrocoagulation unit

    NASA Astrophysics Data System (ADS)

    Symonds, E. M.; Cook, M. M.; McQuaig, S. M.; Ulrich, R. M.; Schenck, R. O.; Lukasik, J. O.; van Vleet, E. S.; Breitbart, M.

    2015-03-01

    To preserve environmental and human health, improved treatment processes are needed to reduce nutrients, microbes, and emerging chemical contaminants from domestic wastewater prior to discharge into the environment. Electrocoagulation (EC) treatment is increasingly used to treat industrial wastewater; however, this technology has not yet been thoroughly assessed for its potential to reduce concentrations of nutrients, a variety of microbial surrogates, and personal care products found in domestic wastewater. This investigation's objective was to determine the efficiency of a benchtop EC unit with aluminum sacrificial electrodes to reduce concentrations of the aforementioned biological and chemical pollutants from raw and tertiary-treated domestic wastewater. EC treatment resulted in significant reductions (p < 0.05, α = 0.05) in phosphate, all microbial surrogates, and several personal care products from raw and tertiary-treated domestic wastewater. When wastewater was augmented with microbial surrogates representing bacterial, viral, and protozoan pathogens to measure the extent of reduction, EC treatment resulted in up to 7-log10 reduction of microbial surrogates. Future pilot and full-scale investigations are needed to optimize EC treatment for the following: reducing nitrogen species, personal care products, and energy consumption; elucidating the mechanisms behind microbial reductions; and performing life cycle analyses to determine the appropriateness of implementation.

  5. Feasibility assessment of electrocoagulation towards a new sustainable wastewater treatment.

    PubMed

    Rodriguez, Jackson; Stopić, Srećko; Krause, Gregor; Friedrich, Bernd

    2007-11-01

    Electrocoagulation (EC) may be a potential answer to environmental problems dealing with water reuse and rational waste management. The aim of this research was to assess the feasibility of EC-process for industrial contaminated effluents from copper production, taking into consideration technical and economical factors. EC-technology claims to offer efficient removal rates for most types of wastewater impurities at low power consumption and without adding any precipitating agents. Real wastewater from Saraka stream with high concentrations of heavy metals was provided by RTB-BOR, a Serbian copper mining and smelting complex. Runs were performed on a 10 l EC-reactor using aluminum plates as sacrificial electrodes and powered by a 40 A supply unit. Results concerning key factors like pH, conductivity and power consumption were measured in real time. Analysis of dissolved metal concentrations before and after treatment were carried out via ICP-OES and confirmed by an independent test via AAS. Several aspects were taken into account, including current density, conductivity, interfacial resistivity and reactor settings throughout the runs, in order to analyze all possible factors playing a role in neutralization and metal removal in real industrial wastewater. Electrode configurations and their effects on energy demand were discussed and exemplified based on fundamentals of colloidal and physical chemistry. Based on experimental data and since no precipitating agents were applied, the EC-process proved to be not only feasible and environmentally-friendly, but also a cost-effective technology The EC-technology provides strategic guidelines for further research and development of sustainable water management processes. However, additional test series concerning continuous operation must be still performed in order to get this concept ready for future large-scale applications.

  6. Defluoridation of drinking water by combined electrocoagulation: effects of the molar ratio of alkalinity and fluoride to Al(III).

    PubMed

    Zhao, Hua-Zhang; Yang, Wei; Zhu, Jun; Ni, Jin-Ren

    2009-03-01

    The defluoridation efficiency (epsilon(F)) of electrocoagulation (EC) is closely related to the pH level of the F(-)-containing solution. The pH level usually needs to be adjusted by adding acid in order to obtain the highest epsilon(F) for the F(-)-containing groundwater. The use of combined EC (CEC), which is the combination of chemical coagulation with EC, was proposed to remove fluoride from drinking water for the first time in this study. The optimal scheme for the design and operation of CEC were obtained through experiments on the treatment of F(-)-containing groundwater. It was found, with OH(-) being the only alkalinity of the raw water, that the highest efficiency would be obtained when the molar ratio of alkalinity and fluoride to Al(III) (gamma(Alkalinity+F)) was controlled at 3.0. However, when the raw water contained HCO(3)(-) alkalinity, a correction coefficient was needed to correct the concentration of HCO(3)(-) to obtain the optimal defluoridation condition of gamma(Alkalinity+F)=3.0 for CEC. The correction coefficient of HCO(3)(-) concentration was concluded as 0.60 from the experiment. For the practical F(-)-containing groundwater treatment, CEC can achieve similar epsilon(F) as an acid-adding EC process. The consumption of aluminum electrode was decreased in CEC. The energy consumption also declined greatly in CEC, which is less than one third of that in the acid-adding EC process.

  7. Electrocoagulation and decolorization of landfill leachate

    NASA Astrophysics Data System (ADS)

    Mussa, Zainab Haider; Othman, Mohamed Rozali; Abdullah, Md Pauzi

    2013-11-01

    In this study, several operating conditions such as electrode material, treatment time, applied voltage, Cl□ concentration and PH of solution were tested on treatability of landfill leachate by using electrocoagulation (EC) method. According to the results, EC method can be used efficiently for the treatment of landfill leachate by using proper operating conditions. The best removal rats were obtained when C (rod) electrode as anode, operating time is 120 min, voltage applied is 10 V, NaCl concentration is 5.85 g/L and the raw PH, for these conditions, 70% color removal was obtained.

  8. Electrocoagulation of Palm Oil Mill Effluent

    PubMed Central

    Agustin, Melissa B.; Sengpracha, Waya P.; Phutdhawong, Weerachai

    2008-01-01

    Electrocoagulation (EC) is an electrochemical technique which has been employed in the treatment of various kinds of wastewater. In this work the potential use of EC for the treatment of palm oil mill effluent (POME) was investigated. In a laboratory scale, POME from a factory site in Chumporn Province (Thailand) was subjected to EC using aluminum as electrodes and sodium chloride as supporting electrolyte. Results show that EC can reduce the turbidity, acidity, COD, and BOD of the POME as well as some of its heavy metal contents. Phenolic compounds are also removed from the effluent. Recovery techniques were employed in the coagulated fraction and the recovered compounds was analysed for antioxidant activity by DPPH method. The isolate was found to have a moderate antioxidant activity. From this investigation, it can be concluded that EC is an efficient method for the treatment of POME. PMID:19139537

  9. The removal of the trivalent chromium from the leather tannery wastewater: the optimisation of the electro-coagulation process parameters.

    PubMed

    GilPavas, E; Dobrosz-Gómez, I; Gómez-García, M Á

    2011-01-01

    The capacity of the electro-coagulation (EC) process for the treatment of the wastewater containing Cr3+, resulting from a leather tannery industry placed in Medellin (Colombia), was evaluated. In order to assess the effect of some parameters, such as: the electrode type (Al and/or Fe), the distance between electrodes, the current density, the stirring velocity, and the initial Cr3+ concentration on its efficiency of removal (%RCr+3), a multifactorial experimental design was used. The %RCr3+ was defined as the response variable for the statistical analysis. In order to optimise the operational values for the chosen parameters, the response surface method (RSM) was applied. Additionally, the Biological Oxygen Demand (BOD5), the Chemical Oxygen Demand (COD), and the Total Organic Carbon (TOC) were monitored during the EC process. The electrodes made of aluminium appeared to be the most effective in the chromium removal from the wastewater under study. At pH equal to 4.52 and at 28°C, the optimal conditions of Cr3+ removal using the EC process were found, as follows: the initial Cr3+ concentration=3,596 mg/L, the electrode gap=0.5 cm, the stirring velocity=382.3 rpm, and the current density=57.87 mA/cm2. At those conditions, it was possible to reach 99.76% of Cr3+ removal, and 64% and 61% of mineralisation (TOC) and COD removal, respectively. A kinetic analysis was performed in order to verify the response capacity of the EC process at optimised parameter values.

  10. Coupling biofiltration process and electrocoagulation using magnesium-based anode for the treatment of landfill leachate.

    PubMed

    Oumar, Dia; Patrick, Drogui; Gerardo, Buelna; Rino, Dubé; Ihsen, Ben Salah

    2016-10-01

    In this research paper, a combination of biofiltration (BF) and electrocoagulation (EC) processes was used for the treatment of sanitary landfill leachate. Landfill leachate is often characterized by the presence of refractory organic compounds (BOD/COD < 0.13). BF process was used as secondary treatment to remove effectively ammonia nitrogen (N-NH4 removal of 94%), BOD (94% removed), turbidity (95% removed) and phosphorus (more than 98% removed). Subsequently, EC process using magnesium-based anode was used as tertiary treatment. The best performances of COD and color removal from landfill leachate were obtained by applying a current density of 10 mA/cm(2) through 30 min of treatment. The COD removal reached 53%, whereas 85% of color removal was recorded. It has been proved that the alkalinity had a negative effect on COD removal during EC treatment. COD removal efficiencies of 52%, 41% and 27% were recorded in the presence of 1.0, 2.0 and 3.0 g/L of sodium bicarbonate (NaHCO3), respectively. Hydroxide ions produced at the cathode electrode reacted with the bicarbonate ions to form carbonates. The presence of bicarbonates in solution hampered the increase in pH, so that the precipitation of magnesium hydroxides could not take place to effectively remove organic pollutants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Treatment of highly concentrated tannery wastewater using electrocoagulation: Influence of the quality of aluminium used for the electrode.

    PubMed

    Elabbas, S; Ouazzani, N; Mandi, L; Berrekhis, F; Perdicakis, M; Pontvianne, S; Pons, M-N; Lapicque, F; Leclerc, J-P

    2016-12-05

    This paper deals with the ability of electrocoagulation (EC) to remove simultaneously COD and chromium from a real chrome tanning wastewater in a batch stirred electro-coagulation cell provided with two aluminium-based electrodes (aluminium/copper/magnesium alloy and pure aluminium). Effects of operating time, current density and initial concentration of Cr(III) and COD have been investigated. The concentrations of pollutants have been successfully reduced to environmentally acceptable levels even if the concentrated effluent requires a long time of treatment of around 6h with a 400A/m(2) current density. The aluminium alloy was found to be more efficient than pure aluminium for removal of COD and chromium. Dilution of the waste has been tested for treatment: high abatement levels could be obtained with shorter time of treatment and lower current densities. Energy consumption of the electrocoagulation process was also discussed. The dilution by half of the concentrated waste leads to a higher abatement performance of both COD and chromium with the best energy efficiency. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Removal of Acid Black 194 dye from water by electrocoagulation with aluminum anode.

    PubMed

    Vidal, Jorge; Villegas, Loreto; Peralta-Hernández, Juan M; Salazar González, Ricardo

    2016-01-01

    Application of an electrocoagulation process (EC) for the elimination of AB194 textile dye from synthetic and textile wastewater (effluent) contaminated with AB194 dye, was carried out using aluminum anodes at two different initial pH values. Tafel studies in the presence and absence of the dye were performed. The aluminum species formed during the electrolysis were quantified by atomic absorption, and the flocs formed in the process were analyzed by HPLC-MS. Complete removal of AB194 from 1.0 L of solution was achieved applying low densities current at initial pH values of 4.0 and 8.0. The removal of AB194 by EC was possible with a short electrolysis time, removing practically 100% of the total organic carbon content and chemical oxygen demand. The final result was completely discolored water lacking dye and organic matter. An effluent contaminated with 126 mg L(-1) AB194 dye from a Chilean textile industry was also treated by EC under optimized experimental conditions, yielding discolored water and considerably decreasing the presence of organic compounds (dye + dyeing additives), with very low concentrations of dissolved Al(3+). Analysis of flocs showed the presence of the original dye without changes in its chemical structure.

  13. Combination of novel coalescing oil water separator and electrocoagulation technique for treatment of petroleum compound contaminated groundwater.

    PubMed

    Oladzad, Sepideh; Fallah, Narges; Nasernejad, Bahram

    2017-07-01

    In the present study a combination of a novel coalescing oil water separator (COWS) and electrocoagulation (EC) technique was used for treatment of petroleum product contaminated groundwater. In the first phase, COWS was used as the primary treatment. Two different types of coalescing media and two levels of flow rates were examined in order to find the optimum conditions. The effluent of COWS was collected in optimum conditions and was treated using an EC process in the second phase of the research. In this phase, preliminary experiments were conducted in order to investigate the effect of EC reaction time and sedimentation time on chemical oxygen demand (COD) removal efficiency. Best conditions for EC reaction time and sedimentation time were obtained to be 5 min and 30 min, respectively. Response surface methodology was applied to evaluate the effect of initial pH, current density and aeration rate on settling velocity (V s ) and effluent COD. The optimum conditions, for achieving maximum values of V s as well as the values of effluent COD, in the range of results were obtained at conditions of 7, 34 mA·cm -2 and 1.5 L·min -1 for initial pH, current density and aeration rate, respectively.

  14. Combined electrocoagulation and electroflotation for removal of fluoride from drinking water.

    PubMed

    Zuo, Qianhai; Chen, Xueming; Li, Wei; Chen, Guohua

    2008-11-30

    A combined electrocoagulation (EC) and electroflotation (EF) process was proposed to remove fluoride from drinking water. Its efficacy was investigated under different conditions. Experimental results showed that the combined process could remove fluoride effectively. The total hydraulic retention time required was only 30 min. After treatment, the fluoride concentration was reduced from initial 4.0-6.0mg/L to lower than 1.0mg/L. The influent pH value was found to be a very important variable that affected fluoride removal significantly. The optimal influent pH range is 6.0-7.0 at which not only can effective defluoridation be achieved, but also no pH readjustment is needed after treatment. In addition, it was found that SO(4)(2-) had negative effect; Ca(2+) had positive effect; while Cl(-) had little effect on the fluoride removal. The EC charge loading, EF charge loading and energy consumption were 3.0 Faradays/m(3), 1.5 Faradays/m(3), and 1.2 kWh/m(3), respectively, under typical conditions where fluoride was reduced from initial 4.0 to 0.87 mg/L.

  15. Bacteria attenuation by iron electrocoagulation governed by interactions between bacterial phosphate groups and Fe(III) precipitates.

    PubMed

    Delaire, Caroline; van Genuchten, Case M; Amrose, Susan E; Gadgil, Ashok J

    2016-10-15

    Iron electrocoagulation (Fe-EC) is a low-cost process in which Fe(II) generated from an Fe(0) anode reacts with dissolved O2 to form (1) Fe(III) precipitates with an affinity for bacterial cell walls and (2) bactericidal reactive oxidants. Previous work suggests that Fe-EC is a promising treatment option for groundwater containing arsenic and bacterial contamination. However, the mechanisms of bacteria attenuation and the impact of major groundwater ions are not well understood. In this work, using the model indicator Escherichia coli (E. coli), we show that physical removal via enmeshment in EC precipitate flocs is the primary process of bacteria attenuation in the presence of HCO3(-), which significantly inhibits inactivation, possibly due to a reduction in the lifetime of reactive oxidants. We demonstrate that the adhesion of EC precipitates to cell walls, which results in bacteria encapsulation in flocs, is driven primarily by interactions between EC precipitates and phosphate functional groups on bacteria surfaces. In single solute electrolytes, both P (0.4 mM) and Ca/Mg (1-13 mM) inhibited the adhesion of EC precipitates to bacterial cell walls, whereas Si (0.4 mM) and ionic strength (2-200 mM) did not impact E. coli attenuation. Interestingly, P (0.4 mM) did not affect E. coli attenuation in electrolytes containing Ca/Mg, consistent with bivalent cation bridging between bacterial phosphate groups and inorganic P sorbed to EC precipitates. Finally, we found that EC precipitate adhesion is largely independent of cell wall composition, consistent with comparable densities of phosphate functional groups on Gram-positive and Gram-negative cells. Our results are critical to predict the performance of Fe-EC to eliminate bacterial contaminants from waters with diverse chemical compositions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Treatment and toxicity reduction of textile dyeing wastewater using the electrocoagulation-electroflotation process.

    PubMed

    Kim, Han-Lae; Cho, Jong-Bok; Park, Yong-Jin; Cho, Il-Hyoung

    2016-07-02

    A pilot-scale study was conducted using the electrocoagulation-electroflotation (EC-EF) process to treat textile dyeing raw wastewater to evaluate treatment performance. The effects of some key factors, such as current density, hydraulic retention time (HRT), and removal of conductivity, total suspended solids (TSS), chemical oxygen demand (COD), and color were investigated. The operating variables were current density of 0-300 A m(-2), HRT of 0-30 min, and a coagulant (anionic polyacrylamide (A-PAM)) dosage of 0-30 mg L(-1). Daphnia magna was used to test acute toxicity in raw and treated wastewater. Under the operating conditions without added coagulant, maxima of 51%, 88%, 84%, and 99% of conductivity, TSS, COD, and color were removed, respectively, with a HRT of 30 min. The coagulant enhanced removal of all wastewater parameters. Removal maxima of 59%, 92%, 94%, and 98% for conductivity, TSS, COD, and color were observed, respectively, with an optimal dosage of 30 mg L(-1) and a shortened HRT of 20 min. The 48 h-LC50 D. magna test showed that the raw wastewater was highly toxic. However, the EC-EF process decreased toxicity of the treated samples significantly, and >70% toxicity reduction was achieved by the EC-EF process with the addition of 15-30 mg L(-1) coagulant, HRT of 20 min, and current density of 150-300 A m(-2). The pilot scale test (0.3 m(3 )h(-1)) shows that the EC-EF process with added coagulant effectively treated textile dyeing wastewater.

  17. Oilfield water treatment by electrocoagulation-reverse osmosis for agricultural use: effects on germination and early growth characteristics of sunflower.

    PubMed

    de Souza, Paulo S A; Cerqueira, Alexandre A; Rigo, Michelle M; de Paiva, Julieta L; Couto, Rafael S P; Merçon, Fábio; Perez, Daniel V; Marques, Monica R C

    2017-05-01

    This study aims to evaluate the effects of oilfield water (OW), treated by a hybrid process of electrocoagulation and reverse osmosis (EC-RO), on seed germination and early growth characteristics of sunflower (Heliantus annus L.). In the EC step, tests were conducted with 28.6 A m -2 current density and 4 min. reaction time. In the RO step, the system was operated with 1 L min -1 constant flow and 2 MPa, 2.5 MPa and 3 MPa feed pressures. In all feed pressures, RO polymeric membranes achieved very high removals of chemical oxygen demand (up to 89%) and oils and greases (100%) from EC-treated effluent. In best feed pressure (2.5 MPa), turbidity, total dissolved salts, electrical conductivity, salinity, toxic ions and sodium adsorption ratio values attained internationally recognized standards for irrigation water. Using EC-RO (feed pressure:2.5 MPa) treated OW, germinated sunflower seeds percentage (86 ± 6%), speed of germination (30 ± 2) and biomass production (49 ± 5 mg) were statistically similar to control (distilled water) results. Vigor index average values obtained using OW treated by EC-RO (3871)were higher than that obtained by OW water treated by EC (3300). The results of this study indicate that EC-RO seems to be a promising alternative for treatment of OW aiming sunflower crops irrigation, since the use of this treated effluent did not affect adversely seed germination and seedling development, and improved seedling vigor. Furthermore, OW treatment by EC-RO reduces sodium levels into acceptable standards values avoiding soil degradation.

  18. Ferrous and ferric ion generation during iron electrocoagulation.

    PubMed

    Lakshmanan, Divagar; Clifford, Dennis A; Samanta, Gautam

    2009-05-15

    Our research on arsenate removal by iron electrocoagulation (EC) produced highly variable results, which appeared to be due to Fe2+ generation without subsequent oxidation to Fe3+. Because the environmental technology literature is contradictory with regard to the generation of ferric or ferrous ions during EC, the objective of this research was to establish the iron species generated during EC with iron anodes. Experimental results demonstrated that Fe2+, not Fe3+, was produced at the iron anode. Theoretical current efficiency was attained based on Fe2+ production with a clean iron rod, regardless of current, dissolved-oxygen (DO) level, or pH (6.5-8.5). The Fe2+ remaining after generation and mixing decreased with increasing pH and DO concentration due to rapid oxidation to Fe3+. At pH 8.5, Fe2+ was completely oxidized, which resulted in the desired Fe(OH)3(s)/ FeOOH(s), whereas, at pH 6.5 and 7.5, incomplete oxidation was observed, resulting in a mixture of soluble Fe2+ and insoluble Fe(OH)3(s)/FeOOH(s). When compared with Fe2+ chemical coagulation, a transient pH increase during EC led to faster Fe2+ oxidation. In summary, for EC in the pH 6.5-7.5 range and at low DO conditions, there is a likelihood of soluble Fe2+ species passing through a subsequentfiltration process resulting in secondary contamination and inefficient contaminant removals.

  19. Escherichia coli Attenuation by Fe Electrocoagulation in Synthetic Bengal Groundwater: Effect of pH and Natural Organic Matter.

    PubMed

    Delaire, Caroline; van Genuchten, Case M; Nelson, Kara L; Amrose, Susan E; Gadgil, Ashok J

    2015-08-18

    Technologies addressing both arsenic and microbial contamination of Bengal groundwater are needed. Fe electrocoagulation (Fe-EC), a simple process relying on the dissolution of an Fe(0) anode to produce Fe(III) precipitates, has been shown to efficiently remove arsenic from groundwater at low cost. We investigated Escherichia coli (E. coli) attenuation by Fe-EC in synthetic Bengal groundwater as a function of Fe dosage rate, total Fe dosed, pH, and presence of natural organic matter (NOM). A 2.5 mM Fe dosage simultaneously achieved over 4-log E. coli attenuation and arsenic removal from 450 to below 10 μg/L. E. coli reduction was significantly enhanced at pH 6.6 compared to pH 7.5, which we linked to the decreased rate of Fe(II) oxidation at lower pH. 3 mg/L-C of NOM (Suwanee River fulvic acid) did not significantly affect E. coli attenuation. Live-dead staining and comparisons of Fe-EC with chemical coagulation controls showed that the primary mechanism of E. coli attenuation is physical removal with Fe(III) precipitates, with inactivation likely contributing as well at lower pH. Transmission electron microscopy showed that EC precipitates adhere to and bridge individual E. coli cells, resulting in large bacteria-Fe aggregates that can be removed by gravitational settling. Our results point to the promising ability of Fe-EC to treat arsenic and bacterial contamination simultaneously at low cost.

  20. How do operating conditions affect As(III) removal by iron electrocoagulation?

    PubMed

    Delaire, Caroline; Amrose, Susan; Zhang, Minghui; Hake, James; Gadgil, Ashok

    2017-04-01

    Iron electrocoagulation (Fe-EC) has been shown to effectively remove arsenic from contaminated groundwater at low cost and has the potential to improve access to safe drinking water for millions of people. Understanding how operating conditions, such as the Fe dosage rate and the O 2 recharge rate, affect arsenic removal at different pH values is crucial to maximize the performance of Fe-EC under economic constraints. In this work, we improved upon an existing computational model to investigate the combined effects of pH, Fe dosage rate, and O 2 recharge rate on arsenic removal in Fe-EC. We showed that the impact of the Fe dosage rate strongly depends on pH and on the O 2 recharge rate, which has important practical implications. We identified the process limiting arsenic removal (As(III) oxidation versus As(V) adsorption) at different pH values, which allowed us to interpret the effect of operating conditions on Fe-EC performance. Finally, we assessed the robustness of the trends predicted by the model, which assumes a constant pH, against lab experiments reproducing more realistic conditions where pH is allowed to drift during treatment as a result of equilibration with atmospheric CO 2 . Our results provide a nuanced understanding of how operating conditions impact arsenic removal by Fe-EC and can inform decisions regarding the operation of this technology in a range of groundwaters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Efficiency analysis of the electrocoagulation and electroflotation treatment of poultry slaughterhouse wastewater using aluminum and graphite anodes.

    PubMed

    Paulista, Larissa Oliveira; Presumido, Pedro Henrique; Theodoro, Joseane Debora Peruço; Pinheiro, Alexei Lorenzetti Novaes

    2018-05-08

    The application of electrocoagulation (EC) and electroflotation (EF) was investigated for the treatment of poultry slaughterhouse wastewater in a bench scale unit cell electrolyzer with different EC-to-EF ratios at current densities of 3, 9, and 15 mA cm -2 . The EC-to-EF ratio was controlled by current reversal using aluminum and graphite electrodes. The electrochemical treatment showed satisfactory removal efficiencies for Al coagulant loads greater than 51.8 mg L -1 . The 4/5 EC to EF ratio (69.1 mg L -1 Al and 32.2 NmL L -1 additional EF gas) and 3/5 (51.8 mg L -1 Al/64 NmL L -1 additional EF gas) presented the best results for the removal of COD (76-85%), color (93-99%), and turbidity (95-99%), with the additional benefit of reducing the electrode consumption and sludge disposal costs proportionally to the EC-to-EF ratio. The effects of the EC-to-EF ratio and the current density on efficiency of the electrochemical treatment for the removal of COD, apparent color, turbidity, TSS, TSD, and NH 3 -N were discussed in the light of the physicochemical and electrochemical processes underlying the removal mechanism for each parameter. In particular, the blow-off mechanism seems to play an important role in the NH 3 -N removal, whereas indirect electrooxidation mechanism accounts for a fraction of the soluble COD removal for the electrodes configuration used in the treatment.

  2. Experimental study on evaluation and optimization of tilt angle of parallel-plate electrodes using electrocoagulation device for oily water demulsification.

    PubMed

    Liu, Yang; Jiang, Wen-Ming; Yang, Jie; Li, Yu-Xing; Chen, Ming-Can; Li, Jian-Na

    2017-08-01

    Tilt angle of parallel-plate electrodes (APE) is very important as it improves the economy of diffusion controlled Electrocoagulation (EC) processes. This study aimed to evaluate and optimize APE of a self-made EC device including integrally rotary electrodes, at a fixed current density of 120 Am -2 . The APEs investigated in this study were selected at 0°, 30°, 45°, 60°, 90°, and a special value (α (d) ) which was defined as a special orientation of electrode when the upper end of anode and the lower end of cathode is in a line vertical to the bottom of reactor. Experiments were conducted to determine the optimum APE for demulsification process using four evaluation indexes, as: oil removal efficiency in the center between electrodes; energy consumption and Al consumption, and besides, a novel universal evaluation index named as evenness index of oil removal efficiency employed to fully reflect distribution characteristics of demulsification efficiency. At a given plate spacing of 4 cm, the optimal APE was found to be α (d) because of its potential of enhancing the mass transfer process within whole EC reactor without addition, external mechanical stirring energy, and finally the four evaluation indexed are 97.07%, 0.11 g Al g -1 oil, 2.99 kwhkg -1 oil, 99.97% and 99.97%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. A comprehensive review of electrocoagulation for water treatment: Potentials and challenges.

    PubMed

    Moussa, Dina T; El-Naas, Muftah H; Nasser, Mustafa; Al-Marri, Mohammed J

    2017-01-15

    Electrocoagulation is an effective electrochemical approach for the treatment of different types of contaminated water and has received considerable attention in recent years due its high efficiency in dealing with numerous stubborn pollutants. It has been successful in dealing with organic and inorganic contaminants with negligible or almost no generation of by-product wastes. During the past decade, vast amount of research has been devoted to utilizing electrocoagulation for the treatment of several types of wastewater, ranging from polluted groundwater to highly contaminated refinery wastewater. This paper offers a comprehensive review of recent literature that has been dedicated to utilizing electrocoagulation for water treatment, focusing on current successes on specific applications in water and wastewater treatment, as well as potentials for future applications. The paper examines such aspects as theory, potential applications, current challenges, recent developments as well as economical concerns associated with the technology. Most of the recent EC research has been focusing on pollutant-specific evaluation without paying attention to cell design, process modeling or industrial applications. This review attempts to highlight the main achievements in the area and outlines the major shortcomings with recommendations for promising research options that can enhance the technology and broaden its range of applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Treatment of Ni-EDTA containing wastewater by electrocoagulation using iron scraps packed-bed anode.

    PubMed

    Ye, Xiaokun; Zhang, Junya; Zhang, Yan; Lv, Yuancai; Dou, Rongni; Wen, Shulong; Li, Lianghao; Chen, Yuancai; Hu, YongYou

    2016-12-01

    The unique electrocoagulator proposed in this study is highly efficient at removing Ni-EDTA, providing a potential remediation option for wastewater containing lower concentrations of Ni-EDTA (Ni ≤ 10 mg L -1 ). In the electrocoagulation (EC) system, cylindrical graphite was used as a cathode, and a packed-bed formed from iron scraps was used as an anode. The results showed that the removal of Ni-EDTA increased with the application of current and favoured acidic conditions. We also found that the iron scrap packed-bed anode was superior in its treatment ability and specific energy consumption (SECS) compared with the iron rod anode. In addition, the packed density and temperature had a large influence on the energy consumption (ECS). Over 94.3% of Ni and 95.8% of TOC were removed when conducting the EC treatment at an applied current of 0.5 A, initial pH of 3, air-purged rate 0.2 L min -1 , anode packed density of 400 kg m -3 temperature of 313 K and time of 30 min. SEM analysis of the iron scraps indicated that the specific area of the anode increased after the EC. The XRD analysis of flocs produced during EC revealed that hematite (α-Fe 2 O 3 ) and magnetite (Fe 3 O 4 ) were the main by-products under aerobic and anoxic conditions, respectively. A kinetic study demonstrated that the removal of Ni-EDTA followed a first-order model with the current parameters. Moreover, the removal efficiency of real wastewater was essentially consistent with that of synthetic wastewater. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Optimization of electrocoagulation (EC) process for the purification of a real industrial wastewater from toxic metals.

    PubMed

    Gatsios, Evangelos; Hahladakis, John N; Gidarakos, Evangelos

    2015-05-01

    In the present work, the efficiency evaluation of electrocoagulation (EC) in removing toxic metals from a real industrial wastewater, collected from Aspropyrgos, Athens, Greece was investigated. Manganese (Mn), copper (Cu) and zinc (Zn) at respective concentrations of 5 mg/L, 5 mg/L and 10 mg/L were present in the wastewater (pH=6), originated from the wastes produced by EBO-PYRKAL munitions industry and Hellenic Petroleum Elefsis Refineries. The effect of operational parameters such as electrode combination and distance, applied current, initial pH and initial metal concentration, was studied. The results indicated that Cu and Zn were totally removed in all experiments, while Mn exhibited equally high removal percentages (approximately 90%). Decreasing the initial pH and increasing the distance between electrodes, resulted in a negative effect on the efficiency and energy consumption of the process. On the other hand, increasing the applied current, favored metal removal but resulted in a power consumption increase. Different initial concentrations did not affect metal removal efficiency. The optimal results, regarding both cost and EC efficiency, were obtained with a combination of iron electrodes, at 2 cm distance, at initial current of 0.1 A and pH=6. After 90 min of treatment, maximum removal percentages obtained were 89% for Mn, 100% for Cu and 100% for Zn, at an energy consumption of 2.55 kWh/m(3). Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Experimental and clinical study of influence of high-frequency electric surgical knives on healing of abdominal incision.

    PubMed

    Ji, Guang-Wei; Wu, Yuan-Zhi; Wang, Xu; Pan, Hua-Xiong; Li, Ping; Du, Wan-Ying; Qi, Zhi; Huang, An; Zhang, Li-Wei; Zhang, Li; Chen, Wen; Liu, Guang-Hua; Xu, Hui; Li, Quan; Yuan, Ai-Hua; He, Xiao-Ping; Mei, Guo-Hua

    2006-07-07

    To study the influence of high-frequency electric surgical knives on healing of abdominal incision. Two hundred and forty white rats were divided into 10(0), 10(2), 10(5), and 10(8) groups and rat models of abdominal operation were induced by using electric surgical knives and common lancets respectively. Then they were respectively given hypodermic injections of normal saline and 0.2 mL quantitative mixture of Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa at a concentration of 10(2), 10(5) and 10(8). On the basis of the animal experiment, 220 patients undergoing abdominal operations (above type II) were randomly allocated into one of following three groups: electric knife (EK, 93 cases), electro-coagulation (EC, 55 cases) and control (72 cases). High-frequency electric surgical knives were used to dissect abdominal tissues and electro-coagulation for hemostasis in EK group. Common lancets and electro-coagulation were applied in EC group. Common lancets and tying silk suture were used in the controls. In all the groups except group 10(0), infection rate of incisional wounds made by electric surgical knives were remarkably higher than that with common lancets. Furthermore, there were significant differences in groups 10(2), 10(5), and 10(8) (P<0.05), but not in group 10(0) (P>0.05) between EK and EC groups. Clinical studies showed a delayed wound healing in 16 cases (17.20%) in EK, 11 cases (16.36%) in EC and 2 cases (2.86%) in the control groups. A significant difference between EK and the control groups (chi2 = 8.57, P<0.01), and between EC and the control groups (chi2 = 5.66, P<0.05) was observed, but not between EK and EC (chi2 = 0.017, P>0.05). High-frequency electric knives may remarkably delay abdominal incision healing. Its application should be minimized so as to reduce the possibility of postoperative complications.

  7. Arsenic removal from groundwater using iron electrocoagulation: effect of charge dosage rate.

    PubMed

    Amrose, Susan; Gadgil, Ashok; Srinivasan, Venkat; Kowolik, Kristin; Muller, Marc; Huang, Jessica; Kostecki, Robert

    2013-01-01

    We demonstrate that electrocoagulation (EC) using iron electrodes can reduce arsenic below 10 μg/L in synthetic Bangladesh groundwater and in real groundwater from Bangladesh and Cambodia, while investigating the effect of operating parameters that are often overlooked, such as charge dosage rate. We measure arsenic removal performance over a larger range of current density than in any other single previous EC study (5000-fold: 0.02 - 100 mA/cm(2)) and over a wide range of charge dosage rates (0.060 - 18 Coulombs/L/min). We find that charge dosage rate has significant effects on both removal capacity (μg-As removed/Coulomb) and treatment time and is the appropriate parameter to maintain performance when scaling to different active areas and volumes. We estimate the operating costs of EC treatment in Bangladesh groundwater to be $0.22/m(3). Waste sludge (~80 - 120 mg/L), when tested with the Toxic Characteristic Leachate Protocol (TCLP), is characterized as non-hazardous. Although our focus is on developing a practical device, our results suggest that As[III] is mostly oxidized via a chemical pathway and does not rely on processes occurring at the anode. Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Environmental Science and Health, Part A, to view the free supplemental file.

  8. Performance evaluation of a bipolar electrolysis/electrocoagulation (EL/EC) reactor to enhance the sludge dewaterability.

    PubMed

    Gharibi, Hamed; Sowlat, Mohammad Hossein; Mahvi, Amir Hossein; Keshavarz, Morteza; Safari, Mohammad Hossein; Lotfi, Saeedeh; Bahram Abadi, Mahnaz; Alijanzadeh, Azim

    2013-01-01

    The present study aimed to evaluate the performance of a bipolar electrolysis/electrocoagulation reactor designed to enhance the sludge dewaterability. The reactor was 15 L in volume, with two series of plates used in it; Ti/RuO(2) plates for the electrolysis of the sludge, and also aluminum and iron plates for electrocoagulation process. The dewaterability of the sludge was determined in terms of its capillary suction time (CST) and specific resistance to filtration (SRF), while the degree of sludge disintegration was determined based on the value of degree of sludge disintegration (DD(SCOD)). The maximum reduction in CST and SRF was observed at a detention time of 20 min and a voltage of 30 V. However, increasing of both detention time and voltage significantly increased the values of CST and SRF even to an extent that they both exceeded those of the untreated sludge. The optimal degree of sludge disintegration achieved by the present study was 2.5%, which was also achieved at a detention time of 20 min and a voltage of 30V. As reported previously, increased DD(SCOD) values led to increasing CST and SRF values, due primarily to the disruption of the sludge flocs. According to the results from the present study, it can be concluded that simultaneous application of electrocoagulation and electrolysis is effective in enhancing the sludge dewaterability, because electrocoagulation helps to achieve a higher degree of sludge disintegration while maintaining the desired sludge dewaterability. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Catalytic decolorization of azo-stuff with electro-coagulation method assisted by cobalt phosphomolybdate modified kaolin.

    PubMed

    Zhuo, Qiongfang; Ma, Hongzhu; Wang, Bo; Gu, Lin

    2007-04-02

    The new catalytic decoloration of C.I. Acid Red 3R with electro-coagulation (EC) method assisted by cobalt phosphomolybdate modified kaolin has been studied. The result showed that this process could effectively remove the C.I. Acid Red 3R contained in wastewater and its color removal efficiency could reach up to 98.3% in 7 min. The kinetics of the catalytic decolorization of Acid Red 3R was also studied. The decolorization reaction order was dependent on the initial concentration [R](0) with respect to the concentration of C.I. Acid Red 3R. At lower [R](0) the order was first, which then decreases with increasing [R](0). The operating parameters such as initial pH, current density and temperature were also investigated. A possible reaction mechanism was proposed.

  10. Performance and Mechanisms of Ultrafiltration Membrane Fouling Mitigation by Coupling Coagulation and Applied Electric Field in a Novel Electrocoagulation Membrane Reactor.

    PubMed

    Sun, Jingqiu; Hu, Chengzhi; Tong, Tiezheng; Zhao, Kai; Qu, Jiuhui; Liu, Huijuan; Elimelech, Menachem

    2017-08-01

    A novel electrocoagulation membrane reactor (ECMR) was developed, in which ultrafiltration (UF) membrane modules are placed between electrodes to improve effluent water quality and reduce membrane fouling. Experiments with feedwater containing clays (kaolinite) and natural organic matter (humic acid) revealed that the combined effect of coagulation and electric field mitigated membrane fouling in the ECMR, resulting in higher water flux than the conventional combination of electrocoagulation and UF in separate units (EC-UF). Higher current densities and weakly acidic pH in the EMCR favored faster generation of large flocs and effectively reduced membrane pore blocking. The hydraulic resistance of the formed cake layers on the membrane surface in ECMR was reduced due to an increase in cake layer porosity and polarity, induced by both coagulation and the applied electric field. The formation of a polarized cake layer was controlled by the applied current density and voltage, with cake layers formed under higher electric field strengths showing higher porosity and hydrophilicity. Compared to EC-UF, ECMR has a smaller footprint and could achieve significant energy savings due to improved fouling resistance and a more compact reactor design.

  11. Aluminium removal from water after defluoridation with the electrocoagulation process.

    PubMed

    Sinha, Richa; Mathur, Sanjay; Brighu, Urmila

    2015-01-01

    Fluoride is the most electronegative element and has a strong affinity for aluminium. Owing to this fact, most of the techniques used for fluoride removal utilized aluminium compounds, which results in high concentrations of aluminium in treated water. In the present paper, a new approach is presented to meet the WHO guideline for residual aluminium concentration as 0.2 mg/L. In the present work, the electrocoagulation (EC) process was used for fluoride removal. It was found that aluminium content in water increases with an increase in the energy input. Therefore, experiments were optimized for a minimum energy input to achieve the target value (0.7 mg/L) of fluoride in resultant water. These optimized sets were used for further investigations of aluminium control. The experimental investigations revealed that use of bentonite clay as coagulant in clariflocculation brings down the aluminium concentration of water below the WHO guideline. Bentonite dose of 2 g/L was found to be the best for efficient removal of aluminium.

  12. Removal of fluoride, SDS, ammonia and turbidity from semiconductor wastewater by combined electrocoagulation-electroflotation.

    PubMed

    Aoudj, S; Khelifa, A; Drouiche, N

    2017-08-01

    Semiconductor industry effluents contain organic and inorganic pollutants, such as sodium dodecyl sulfate (SDS), fluoride and ammonia, at high levels which consists a major environmental issue. A combined EC-EF process is proposed as a post-treatment after precipitation for simultaneous clarification and removal of pollutants. In EC step, a hybrid Fe-Al was used as the soluble anode in order to avoid supplementary EC step. EC-Fe is more suitable for SDS removal; EC-Al is more suitable for fluoride removal, while EC with hybrid Al-Fe makes a good compromise. Clarification and ammonia oxidation were achieved in the EF step. Effects of anodic material, initial pH, current, anion nature, chloride concentration and initial pollutant concentration were studied. The final concentrations may reach 0.27, 6.23 and 0.22 mg L -1 for SDS, fluoride and ammonia respectively. These concentrations are far lower than the correspondent discharge limits. Similarly, the final turbidity was found 4.35 NTU which is lower than 5NTU and the treated water does not need further filtration before discharge. Furthermore, the EC-EF process proves to be sufficiently energy-efficient with less soluble electrode consumption. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Decolorization of basic dye solutions by electrocoagulation: an investigation of the effect of operational parameters.

    PubMed

    Daneshvar, N; Oladegaragoze, A; Djafarzadeh, N

    2006-02-28

    Electrocoagulation (EC) is one of the most effective techniques to remove color and organic pollutants from wastewater, which reduces the sludge generation. In this paper, electrocoagulation has been used for the removal of color from solutions containing C. I. Basic Red 46 (BR46) and C. I. Basic Blue 3 (BB3). These dyes are used in the wool and blanket factories for fiber dyeing. The effect of operational parameters such as current density, initial pH of the solution, time of electrolysis, initial dye concentration and solution conductivity were studied in an attempt to reach higher removal efficiency. The findings in this study shows that an increase in the current density up to 60-80 A m(-2) enhanced the color removal efficiency, the electrolysis time was 5 min and the range of pH was determined between 5.5 and 8.5 for two mentioned dye solutions. It was found that for, the initial concentration of dye in solutions should not be higher than 80 mg l(-1) in order to achieve a high color removal percentage. The optimum conductivity was found to be 8 mS cm(-1), which was adjusted using proper amount of NaCl with the dye concentration of 50 mg l(-1). Electrical energy consumption in the above conditions for the decolorization of the dye solutions containing BR46 and BB3 were 4.70 kWh(kgdye removed)(-1) and 7.57 kWh(kgdye removed)(-1), respectively. Also, during the EC process under the optimized conditions, the COD decreased by more than 75% and 99% in dye solutions containing BB3 and BR46, respectively.

  14. Modeling As(III) oxidation and removal with iron electrocoagulation in groundwater.

    PubMed

    Li, Lei; van Genuchten, Case M; Addy, Susan E A; Yao, Juanjuan; Gao, Naiyun; Gadgil, Ashok J

    2012-11-06

    Understanding the chemical kinetics of arsenic during electrocoagulation (EC) treatment is essential for a deeper understanding of arsenic removal using EC under a variety of operating conditions and solution compositions. We describe a highly constrained, simple chemical dynamic model of As(III) oxidation and As(III,V), Si, and P sorption for the EC system using model parameters extracted from some of our experimental results and previous studies. Our model predictions agree well with both data extracted from previous studies and our observed experimental data over a broad range of operating conditions (charge dosage rate) and solution chemistry (pH, co-occurring ions) without free model parameters. Our model provides insights into why higher pH and lower charge dosage rate (Coulombs/L/min) facilitate As(III) removal by EC and sheds light on the debate in the recent published literature regarding the mechanism of As(III) oxidation during EC. Our model also provides practically useful estimates of the minimum amount of iron required to remove 500 μg/L As(III) to <50 μg/L. Parameters measured in this work include the ratio of rate constants for Fe(II) and As(III) reactions with Fe(IV) in synthetic groundwater (k(1)/k(2) = 1.07) and the apparent rate constant of Fe(II) oxidation with dissolved oxygen at pH 7 (k(app) = 10(0.22) M(-1)s(-1)).

  15. Arsenic and fluoride removal from groundwater by electrocoagulation using a continuous filter-press reactor.

    PubMed

    Guzmán, Athziri; Nava, José L; Coreño, Oscar; Rodríguez, Israel; Gutiérrez, Silvia

    2016-02-01

    We investigated simultaneous arsenic and fluoride removal from ground water by electrocoagulation (EC) using aluminum as the sacrificial anode in a continuous filter-press reactor. The groundwater was collected at a depth of 320 m in the Bajío region in Guanajuato Mexico (arsenic 43 µg L(-1), fluoride 2.5 mg L(-1), sulfate 89.6 mg L(-1), phosphate 1.8 mg L(-1), hydrated silica 112.4 mg L(-1), hardness 9.8 mg L(-1), alkalinity 31.3 mg L(-1), pH 7.6 and conductivity 993 µS cm(-1)). EC was performed after arsenite was oxidized to arsenate by addition of 1 mg L(-1) hypochlorite. The EC tests revealed that at current densities of 4, 5 and 6 mA cm(-2) and flow velocities of 0.91 and 1.82 cm s(-1), arsenate was abated and residual fluoride concentration satisfies the WHO standard (CF < 1.5 mg L(-1)). Spectrometric analyses performed on aluminum flocs indicated that these are mainly composed of aluminum-silicates of calcium and magnesium. Arsenate removal by EC involves adsorption on aluminum flocs, while fluoride replaces a hydroxyl group from aluminum aggregates. The best EC was obtained at 4 mA cm(-2) and 1.82 cm s(-1) with electrolytic energy consumption of 0.34 KWh m(-3). Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Efficient treatment of an electroplating wastewater containing heavy metal ions, cyanide, and organics by H2O2 oxidation followed by the anodic Fenton process.

    PubMed

    Zhao, Xu; Wang, Haidong; Chen, Fayuan; Mao, Ran; Liu, Huijuan; Qu, Jiuhui

    2013-01-01

    A real electroplating wastewater, containing heavy metals, cyanide, and organic contaminants, was treated by electrocoagulation (EC), H2O2 oxidation, H2O2 pre-oxidation followed by EC, and the anodic Fenton process and the efficacy of the processes was compared. Concentration of cyanide, Cu, Ni, Zn, and Cr was largely decreased by EC within 5 min. When the reaction time was extended, removal of residual cyanide, Cu, and Ni was limited. In H2O2 oxidation, the concentration of cyanide decreased from initial 75 to 12 mg L(-1) in 30 min. The effluents from the H2O2 oxidation were further treated by EC or anodic Fenton. In EC, the concentration of total cyanide, Ni, and Cu decreased to below 0.3, 0.5, and 1.5 mg L(-1), respectively. Removal efficiency of chemical oxygen demand by EC was less than 20.0%. By contrast, there was 73.5% reduction by the anodic Fenton process with 5 mM H2O2 at 30 min; this can be attributed to the oxidation induced by hydroxyl radicals generated by the reaction of H2O2 with the electrogenerated Fe(2+). Meanwhile, residual cyanide, Cu, and Ni can also be efficiently removed. Transformation of organic components in various processes was analyzed using UV-visible and fluorescence excitation-emission spectra.

  17. Dynamics of Chromium(VI) Removal from Drinking Water by Iron Electrocoagulation.

    PubMed

    Pan, Chao; Troyer, Lyndsay D; Catalano, Jeffrey G; Giammar, Daniel E

    2016-12-20

    The potential for new U.S. regulations for Cr(VI) in drinking water have spurred strong interests in improving technologies for Cr(VI) removal. This study examined iron electrocoagulation for Cr(VI) removal at conditions directly relevant to drinking water treatment. Cr(VI) is chemically reduced to less soluble Cr(III) species by the Fe(II) produced from an iron anode, and XANES spectra indicate that the Cr is entirely Cr(III) in solid-phases produced in electrocoagulation. The dynamics of Cr(VI) removal in electrocoagulation at pH 6 and pH 8 at both oxic and anoxic conditions can be described by a new model that incorporates Fe(II) release from the anode and heterogeneous and homogeneous reduction of Cr(VI) by Fe(II). Heterogeneous Cr(VI) reduction by adsorbed Fe(II) was critical to interpreting Cr(VI) removal at pH 6, and the Fe- and Cr-containing EC product was found to catalyze the redox reaction. Dissolved oxygen (DO) did not observably inhibit Cr(VI) removal because Fe(II) reacts with DO more slowly than it does with Cr(VI), and Cr(VI) removal was faster at higher pH. Even in the presence of common groundwater solutes, iron electrocoagulation lowered Cr(VI) concentrations to levels well below California's 10 μg/L.

  18. Treatment of As(V) and As(III) by electrocoagulation using Al and Fe electrode.

    PubMed

    Kuan, W H; Hu, C Y; Chiang, M C

    2009-01-01

    A batch electrocoagulation (EC) process with bipolar electrode and potentiodynamic polarization tests with monopolar systems were investigated as methods to explore the effects of electrode materials and initial solution pH on the As(V) and As(III) removal. The results displayed that the system with Al electrode has higher reaction rate during the initial period from 0 to 25 minutes than that of Fe electrode for alkaline condition. The pH increased with the EC time because the As(V) and As(III) removal by either co-precipitation or adsorption resulted in that the OH positions in Al-hydroxide or Fe-hydroxide were substituted by As(V) and As(III). The pH in Fe electrode system elevate higher than that in Al electrode because the As(V) removal substitutes more OH position in Fe-hydroxide than that in Al-hydroxide. EC system with Fe electrode can successfully remove the As(III) but system with Al electrode cannot because As(III) can strongly bind to the surface of Fe-hydroxide with forming inner-sphere species but weakly adsorb to the Al-hydroxide surface with forming outer-sphere species. The acidic solution can destroy the deposited hydroxide passive film then allow the metallic ions liberate into the solution, therefore, the acidic initial solution can enhance the As(V) and As(III) removal. The over potential calculation and potentiodynamic polarization tests reveal that the Fe electrode systems possess higher over potential and pitting potential than that of Al electrode system due to the fast hydrolysis of and the occurrence of Fe-hydroxide passive film.

  19. Degradation of pentachlorophenol by hydroxyl radicals and sulfate radicals using electrochemical activation of peroxomonosulfate, peroxodisulfate and hydrogen peroxide.

    PubMed

    Govindan, Kadarkarai; Raja, Mohan; Noel, Michael; James, E J

    2014-05-15

    The present study is to investigate the reactivity of free radicals (SO4(-) and HO) generated from common oxidants (peroxomonosulfate (PMS), peroxodisulfate (PDS) and hydrogen peroxide (HP)) activated by electrochemically generated Fe(2+)/Fe(3+) ions which furthermore are evaluated to destroy pentachlorophenol (PCP) in aqueous solution. The effect of solution pH and amount of oxidants (PMS, PDS and HP) in electrocoagulation (EC) on PCP degradation is analyzed in detail. The experimental results reveal that, optimum initial solution pH is 4.5 and PMS is more efficient oxidant addition in EC. 75% PCP degradation is achieved at 60min electrolysis time from PMS assisted EC. According to the first order rate constant, faster PCP degradation rate is obtained by PMS assisted EC. The PCP degradation rate by oxidant assisted EC is observed in the following order: EC/PMS>EC/PDS>EC/HP>EC. Further to identify the influences of experimental factors involved in PCP degradation by oxidant assisted EC, an experimental design based on an orthogonal array (OA) L9 (3(3)) is proposed using Taguchi method. The factors that most significantly affect the process robustness are identified as A (oxidant) and B (pH) which together account for nearly 86% of the variance. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Formation of macroscopic surface layers on Fe(0) electrocoagulation electrodes during an extended field trial of arsenic treatment.

    PubMed

    van Genuchten, Case M; Bandaru, Siva R S; Surorova, Elena; Amrose, Susan E; Gadgil, Ashok J; Peña, Jasquelin

    2016-06-01

    Extended field trials to remove arsenic (As) via Fe(0) electrocoagulation (EC) have demonstrated consistent As removal from groundwater to concentrations below 10 μg L(-1). However, the coulombic performance of long-term EC field operation is lower than that of laboratory-based systems. Although EC electrodes used over prolonged periods show distinct passivation layers, which have been linked to decreased treatment efficiency, the spatial distribution and mineralogy of such surface layers have not been investigated. In this work, we combine wet chemical measurements with sub-micron-scale chemical maps and selected area electron diffraction (SAED) to determine the chemical composition and mineral phase of surface layers formed during long-term Fe(0) EC treatment. We analyzed Fe(0) EC electrodes used for 3.5 months of daily treatment of As-contaminated groundwater in rural West Bengal, India. We found that the several mm thick layer that formed on cathodes and anodes consisted of primarily magnetite, with minor fractions of goethite. Spatially-resolved SAED patterns also revealed small quantities of CaCO3, Mn oxides, and SiO2, the source of which was the groundwater electrolyte. We propose that the formation of the surface layer contributes to decreased treatment performance by preventing the migration of EC-generated Fe(II) to the bulk electrolyte, where As removal occurs. The trapped Fe(II) subsequently increases the surface layer size at the expense of treatment efficiency. Based on these findings, we discuss several simple and affordable methods to prevent the efficiency loss due to the surface layer, including alternating polarity cycles and cleaning the Fe(0) surface mechanically or via electrolyte scouring. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Energy efficient electrocoagulation using a new flow column reactor to remove nitrate from drinking water - Experimental, statistical, and economic approach.

    PubMed

    Hashim, Khalid S; Shaw, Andy; Al Khaddar, Rafid; Pedrola, Montserrat Ortoneda; Phipps, David

    2017-07-01

    In this investigation, a new bench-scale electrocoagulation reactor (FCER) has been applied for drinking water denitrification. FCER utilises the concepts of flow column to mix and aerate the water. The water being treated flows through the perforated aluminium disks electrodes, thereby efficiently mixing and aerating the water. As a result, FCER reduces the need for external stirring and aerating devices, which until now have been widely used in the electrocoagulation reactors. Therefore, FCER could be a promising cost-effective alternative to the traditional lab-scale EC reactors. A comprehensive study has been commenced to investigate the performance of the new reactor. This includes the application of FCER to remove nitrate from drinking water. Estimation of the produced amount of H 2 gas and the yieldable energy from it, an estimation of its preliminary operating cost, and a SEM (scanning electron microscope) investigation of the influence of the EC process on the morphology of the surface of electrodes. Additionally, an empirical model was developed to reproduce the nitrate removal performance of the FCER. The results obtained indicated that the FCER reduced the nitrate concentration from 100 to 15 mg/L (World Health Organization limitations for infants) after 55 min of electrolysing at initial pH of 7, GBE of 5 mm, CD of 2 mA/cm 2 , and at operating cost of 0.455 US $/m 3 . Additionally, it was found that FCER emits H 2 gas enough to generate a power of 1.36 kW/m 3 . Statistically, the relationship between the operating parameters and nitrate removal could be modelled with R 2 of 0.848. The obtained SEM images showed a large number dents on anode's surface due to the production of aluminium hydroxides. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  2. Process optimization via response surface methodology in the treatment of metal working industry wastewater with electrocoagulation.

    PubMed

    Guvenc, Senem Yazici; Okut, Yusuf; Ozak, Mert; Haktanir, Birsu; Bilgili, Mehmet Sinan

    2017-02-01

    In this study, process parameters in chemical oxygen demand (COD) and turbidity removal from metal working industry (MWI) wastewater were optimized by electrocoagulation (EC) using aluminum, iron and steel electrodes. The effects of process variables on COD and turbidity were investigated by developing a mathematical model using central composite design method, which is one of the response surface methodologies. Variance analysis was conducted to identify the interaction between process variables and model responses and the optimum conditions for the COD and turbidity removal. Second-order regression models were developed via the Statgraphics Centurion XVI.I software program to predict COD and turbidity removal efficiencies. Under the optimum conditions, removal efficiencies obtained from aluminum electrodes were found to be 76.72% for COD and 99.97% for turbidity, while the removal efficiencies obtained from iron electrodes were found to be 76.55% for COD and 99.9% for turbidity and the removal efficiencies obtained from steel electrodes were found to be 65.75% for COD and 99.25% for turbidity. Operational costs at optimum conditions were found to be 4.83, 1.91 and 2.91 €/m 3 for aluminum, iron and steel electrodes, respectively. Iron electrode was found to be more suitable for MWI wastewater treatment in terms of operational cost and treatment efficiency.

  3. Removal of trace metal contaminants from potable water by electrocoagulation.

    PubMed

    Heffron, Joe; Marhefke, Matt; Mayer, Brooke K

    2016-06-21

    This study investigated the effects of four operational and environmental variables on the removal of trace metal contaminants from drinking water by electrocoagulation (EC). Removal efficiencies for five metals (arsenic, cadmium, chromium, lead and nickel) were compared under varying combinations of electrode material, post-treatment, water composition and pH. Iron electrodes out-performed aluminum electrodes in removing chromium and arsenic. At pH 6.5, aluminum electrodes were slightly more effective at removing nickel and cadmium, while at pH 8.5, iron electrodes were more effective for these metals. Regardless of electrode, cadmium and nickel removal efficiencies were higher at pH 8.5 than at pH 6.5. Post-EC treatment using membrane filtration (0.45 μm) enhanced contaminant removal for all metals but nickel. With the exception of lead, all metals exhibited poorer removal efficiencies as the ionic strength of the background electrolyte increased, particularly in the very high-solids synthetic groundwaters. Residual aluminum concentrations were lowest at pH 6.5, while iron residuals were lowest in low ionic strength waters. Both aluminum and iron residuals required post-treatment filtration to meet drinking water standards. EC with post-treatment filtration appears to effectively remove trace metal contaminants to potable water standards, but both reactor and source water parameters critically impact removal efficiency.

  4. Removal of trace metal contaminants from potable water by electrocoagulation

    NASA Astrophysics Data System (ADS)

    Heffron, Joe; Marhefke, Matt; Mayer, Brooke K.

    2016-06-01

    This study investigated the effects of four operational and environmental variables on the removal of trace metal contaminants from drinking water by electrocoagulation (EC). Removal efficiencies for five metals (arsenic, cadmium, chromium, lead and nickel) were compared under varying combinations of electrode material, post-treatment, water composition and pH. Iron electrodes out-performed aluminum electrodes in removing chromium and arsenic. At pH 6.5, aluminum electrodes were slightly more effective at removing nickel and cadmium, while at pH 8.5, iron electrodes were more effective for these metals. Regardless of electrode, cadmium and nickel removal efficiencies were higher at pH 8.5 than at pH 6.5. Post-EC treatment using membrane filtration (0.45 μm) enhanced contaminant removal for all metals but nickel. With the exception of lead, all metals exhibited poorer removal efficiencies as the ionic strength of the background electrolyte increased, particularly in the very high-solids synthetic groundwaters. Residual aluminum concentrations were lowest at pH 6.5, while iron residuals were lowest in low ionic strength waters. Both aluminum and iron residuals required post-treatment filtration to meet drinking water standards. EC with post-treatment filtration appears to effectively remove trace metal contaminants to potable water standards, but both reactor and source water parameters critically impact removal efficiency.

  5. Composite wastewater treatment by aerated electrocoagulation and modified peroxi-coagulation processes.

    PubMed

    Kumar, Abhijeet; Nidheesh, P V; Suresh Kumar, M

    2018-08-01

    Treatment of composite wastewater generating from the industrial estates is a great challenge. The present study examines the applicability of aerated electrocoagulation and modified peroxi-coagulation processes for removing color and COD from composite wastewater. Iron plates were used as anodes and cathodes in both electrochemical processes and experiments were carried out in a working volume of 2 L. Aeration enhanced the efficiency of electrocoagulation process significantly. More than 50% of COD and 60% of color were removed after 1 h of electrocoagulation process operated at pH 3 and applied voltage of 1 V. Efficiency of the modified peroxi-coagulation process was significantly higher than that of aerated electrocoagulation. COD and color removal efficiencies of the modified peroxi-coagulation process were found as 77.7% and 97%, respectively after 1 h of electrolysis operated at 1 V, solution pH 3 and 50 mM hydrogen peroxide addition. This improved efficiency of modified peroxi-coagulation compared to aerated electrocoagulation is mainly due to the attack of in-situ generated hydroxyl radicals. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Electrocoagulation of bio-filtrated landfill leachate: Fractionation of organic matter and influence of anode materials.

    PubMed

    Dia, Oumar; Drogui, Patrick; Buelna, Gerardo; Dubé, Rino; Ihsen, Ben Salah

    2017-02-01

    Electrocoagulation (EC) was employed to treat residual organic matter from a landfill leachate pretreated by an aerated bio-filter system. Organic matter (humic acids (HA), fulvic acids (FA) and hydrophilic compounds (Hyl)) was fractionated using DAX-8 resin in order to estimate the efficiency of EC on each fraction. Initial characterization of the bio-filtrated landfill leachate showed that humic substances (HA + FA) represented nearly 90% of TOC. The effects of current densities, type of anode (Aluminum versus iron), and treatment time on the performance of COD removal were investigated. The best COD removal performances were recorded at a current density ranging between 8.0 and 10 mA cm -2 during 20 min of treatment time. Under these conditions, 70% and 65% of COD were removed using aluminum and iron electrodes, respectively. The fractionating of organic matter after EC treatment revealed that HA was completely removed using either aluminum or iron anode. However, FA and Hyl fractions were partially removed, with the percentages varying from 57 to 60% and 37-46%, respectively. FA and Hyl removal were quite similar using either aluminum or iron anode. Likewise, a significant decrease in 254-nm absorbance was recorded (UV 254 removal of 79-80%) using either type of anode. These results proved that EC is a suitable and efficient approach for treating the residual refractory organic matter from a landfill leachate previously treated by a biological system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Monitoring and removal of residual phthalate esters and pharmaceuticals in the drinking water of Kaohsiung City, Taiwan.

    PubMed

    Yang, Gordon C C; Yen, Chia-Heng; Wang, Chih-Lung

    2014-07-30

    This study monitored the occurrence and removal efficiencies of 8 phthalate esters (PAEs) and 13 pharmaceuticals present in the drinking water of Kaohsiung City, Taiwan. The simultaneous electrocoagulation and electrofiltration (EC/EF) process was used to remove the contaminants. To this end, a monitoring program was conducted and a novel laboratory-prepared tubular carbon nanofiber/carbon/alumina composite membrane (TCCACM) was incorporated into the EC/EF treatment module (collectively designated as "TCCACM-EC/EF treatment module") to remove the abovementioned compounds from water samples. The monitoring results showed that the concentrations of PAEs were lower in water samples from drinking fountains as compared with tap water samples. No significant differences were found between the concentrations of pharmaceuticals in the two types of water samples. Under optimal operating conditions, the TCCACM-EC/EF treatment module yielded the lowest residual concentrations, ranging from not detected (ND) to 52ng/L for PAEs and pharmaceuticals of concern in the tap water samples. Moreover, the performance of the TCCACM-EC/EF treatment module is comparable with a series of treatment units employed for the drinking fountain water treatment system. The relevant removal mechanisms involved in the TCCACM-EC/EF treatment module were also discussed in this work. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Color removal from acid and reactive dye solutions by electrocoagulation and electrocoagulation/adsorption processes.

    PubMed

    Bellebia, S; Kacha, S; Bouberka, Z; Bouyakoub, A Z; Derriche, Z

    2009-04-01

    In this study, electrocoagulation of Marine Blue Erionyl MR (acid dye) and electrocoagulation followed by adsorption of Brilliant Blue Levafix E-BRA (reactive dye) from aqueous solutions were investigated, using aluminum electrodes and granular activated carbon (GAC). In the electrocoagulation and adsorption of dyestuff solutions, the effects of current density, loading charge, pH, conductivity, stirring velocity, contact time, and GAC concentration were examined. The optimum conditions for the electrocoagulation process were identified as loading charges 7.46 and 1.49 F/m3, for a maximum abatement of 200 mg/L reactive and acid dye, respectively. The residual reactive dye concentration was completely removed with 700 mg/L GAC. The results of this investigation provide important data for the development of a combined process to remove significant concentrations of recalcitrant dyes from water, using moderate activated carbon energy and aluminum consumption, and thereby lowering the cost of treatment.

  9. Optimization of an integrated electrodisinfection/electrocoagulation process with Al bipolar electrodes for urban wastewater reclamation.

    PubMed

    Cotillas, Salvador; Llanos, Javier; Cañizares, Pablo; Mateo, Sara; Rodrigo, Manuel A

    2013-04-01

    In this work, a novel integrated electrochemical process for urban wastewater regeneration is described. The electrochemical cell consists in a Boron Doped Diamond (BDD) or a Dimensionally Stable Anode (DSA) as anode, a Stainless Steel (SS) as cathode and a perforated aluminum plate, which behaves as bipolar electrode, between anode and cathode. Thus, in this cell, it is possible to carry out, at the same time, two different electrochemical processes: electrodisinfection (ED) and electrocoagulation (EC). The treatment of urban wastewater with different anodes and different operating conditions is studied. First of all, in order to check the process performance, experiments with synthetic wastewaters were carried out, showing that it is possible to achieve a 100% of turbidity removal by the electrodissolution of the bipolar electrode. Next, the effect of the current density and the anode material are studied during the ED-EC process of actual effluents. Results show that it is possible to remove Escherichia coli and turbidity simultaneously of an actual effluent from a WasteWater Treatment Facility (WWTF). The use of BDD anodes allows to remove the E. coli completely at an applied electric charge of 0.0077 A h dm(-3) when working with a current density of 6.65 A m(-2). On the other hand, with DSA anodes, the current density necessary to achieve the total removal of E. coli is higher (11.12 A m(-2)) than that required with BDD anodes. Finally, the influence of cell flow path and flow rate have been studied. Results show that the performance of the process strongly depends on the characteristics of the initial effluent (E. coli concentration and Cl(-)/NH(4)(+) initial ratio) and that a cell configuration cathode (inlet)-anode (outlet) and a higher flow rate enhance the removal of the turbidity from the treated effluent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Post-treatment of molasses wastewater by electrocoagulation and process optimization through response surface analysis.

    PubMed

    Tsioptsias, C; Petridis, D; Athanasakis, N; Lemonidis, I; Deligiannis, A; Samaras, P

    2015-12-01

    Molasses wastewater is a high strength effluent of food industry such as distilleries, sugar and yeast production plants etc. It is characterized by a dark brown color and exhibits a high content in substances of recalcitrant nature such as melanoidins. In this study, electrocoagulation (EC) was studied as a post treatment step for biologically treated molasses wastewater with high nitrogen content obtained from a baker's yeast industry. Iron and copper electrodes were used in various forms; the influence and interaction of current density, molasses wastewater dilution, and reaction time, on COD, color, ammonium and nitrate removal rates and operating cost were studied and optimized through Box Behnken's response surface analysis. Reaction time varied from 0.5 to 4 h, current density varied from 5 to 40 mA/cm(2) and dilution from 0 to 90% (v/v expressed as water concentration). pH, conductivity and temperature measurements were also carried out during each experiment. From preliminary experiments, it was concluded that the application of aeration and sample dilution, considerably influenced the kinetics of the process. The obtained results showed that COD removal varied between 10 and 54%, corresponding to an operation cost ranging from 0.2 to 33 euro/kg COD removed. Significant removal rates were obtained for nitrogen as nitrate and ammonium (i.e. 70% ammonium removal). A linear relation of COD and ammonium to the design parameters was observed, while operation cost and nitrate removal responded in a curvilinear function. A low ratio of electrode surface to treated volume was used, associated to a low investment cost; in addition, iron wastes could be utilized as low cost electrodes i.e. iron fillings from lathes, aiming to a low operation cost due to electrodes replacement. In general, electrocoagulation proved to be an effective and low cost process for biologically treated molasses-wastewater treatment for additional removal of COD and nitrogen content and color reduction. Treated effluent samples with good quality were produced by EC, with COD, NH4-N and NO3-N concentrations of 180, 52 and 2 mg/l respectively. Response surface analysis revealed that optimized conditions could be established under moderate molasses wastewater dilution, (e.g. 45%), at 3.5 h treatment time and 33 mA/cm(2) current density. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Market Analysis and Material Evaluation of Coagulants for Reverse Osmosis Water Purification Units

    DTIC Science & Technology

    1990-09-28

    three identified primary coagulants. Electrocoagulation , an emerging technology, was also discovered as being a relatively new area of research with great...there is yet another avenue the Army needs to explore -- electrocoagulation . 4.3.2 Electrocoagulation | * Electrocoagulation processes utilize an...7). A typical electrocoagulator consists of a combination of a treating chamber, which operates as an electrolytic cell, with a water-inlet and a

  12. Treatment of industrial estate wastewater by the application of electrocoagulation process using iron electrodes.

    PubMed

    Yavuz, Y; Ögütveren, Ü B

    2018-02-01

    In this study electrocoagulation (EC) of industrial estate wastewater taken from the inlet of wastewater treatment plant was investigated using sacrificial iron electrodes. Employing a pole changer to homogenous consumption of electrodes, studies on the parameters such as current density, supporting electrolyte concentration and initial pH, which have significant effects on COD removal and hence the energy consumption, were performed. Hydrogen peroxide was used in different concentrations to observe its effects on COD removal efficiency and the energy consumption. Sludge productions were also calculated for all experiments. COD removal efficiency of ∼92% was obtained at the best experimental conditions (i = 30 mA/cm 2 , SE = 3 mM Na 2 SO 4 , pH = original pH (∼6) of the wastewater, 1500 mg/L H 2 O 2 ) with an energy cost of €3.41/m 3 wastewater treated and the sludge production of 5.45 g per g COD removed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Sono assisted electrocoagulation process for the removal of pollutant from pulp and paper industry effluent.

    PubMed

    Asaithambi, P; Aziz, Abdul Raman Abdul; Sajjadi, Baharak; Daud, Wan Mohd Ashri Bin Wan

    2017-02-01

    In the present work, the efficiency of the sonication, electrocoagulation, and sono-electrocoagulation process for removal of pollutants from the industrial effluent of the pulp and paper industry was compared. The experimental results showed that the sono-electrocoagulation process yielded higher pollutant removal percentage compared to the sonication and electrocoagulation process alone. The effect of the operating parameters in the sono-electrocoagulation process such as electrolyte concentration (1-5 g/L), current density (1-5 A/dm 2 ), effluent pH (3-11), COD concentration (1500-6000 mg/L), inter-electrode distance (1-3 cm), and electrode combination (Fe and Al) on the color removal, COD removal, and power consumption were studied. The maximum color and COD removal percentages of 100 and 95 %, respectively, were obtained at the current density of 4 A/dm 2 , electrolyte concentration of 4 g/L, effluent pH of 7, COD concentration of 3000 mg/L, electrode combination of Fe/Fe, inter-electrode distance of 1 cm, and reaction time of 4 h, respectively. The color and COD removal percentages were analyzed by using an UV/Vis spectrophotometer and closed reflux method. The results showed that the sono-electrocoagulation process could be used as an efficient and environmental friendly technique for complete pollutant removal.

  14. Emerging usage of electrocoagulation technology for oil removal from wastewater: A review.

    PubMed

    An, Chunjiang; Huang, Gordon; Yao, Yao; Zhao, Shan

    2017-02-01

    Electrocoagulation is a simple and efficient treatment method involving the electrodissolution of sacrificial anodes and formation of hydroxo-metal products as coagulants, while the simultaneous production of hydrogen at the cathode facilitates the pollutant removal by flotation. Oil is one of the most important hydrocarbon products in the modern world. It can cause environmental pollution during various stages of production, transportation, refining and use. Electrocoagulation treatment is particularly effective for destabilization of oil-in-water emulsions by neutralizing charges and bonding oil pollutants to generated flocs and hydrogen bubbles. The development of electrocoagulation technologies provided a promising alternative for oil removal from wastewater. This paper presents a review of emerging electrochemical technologies used for treating oil-containing wastewater. It includes a brief description of the oily wastewater origin and characteristics. The treatment processes developed so far for oily wastewater and the electrocoagulation mechanisms are also introduced. This paper summarizes the current applications of electrocoagulation for oil removal from wastewater. The factors that influence the electrocoagulation treatment efficiencies as well as the process optimization and modeling studies are discussed. The state-of-the-art and development trends of electrocoagulation process for oil removal are further introduced. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Defluoridation of drinking water by electrocoagulation/electroflotation in a stirred tank reactor with a comparative performance to an external-loop airlift reactor.

    PubMed

    Essadki, A H; Gourich, B; Vial, Ch; Delmas, H; Bennajah, M

    2009-09-15

    Defluoridation using batch electrocoagulation/electroflotation (EC/EF) was carried out in two reactors for comparison purpose: a stirred tank reactor (STR) close to a conventional EC cell and an external-loop airlift reactor (ELAR) that was recently described as an innovative reactor for EC. The respective influences of current density, initial concentration and initial pH on the efficiency of defluoridation were investigated. The same trends were observed in both reactors, but the efficiency was higher in the STR at the beginning of the electrolysis, whereas similar values were usually achieved after 15min operation. The influence of the initial pH was explained using the analyses of sludge composition and residual soluble aluminum species in the effluents, and it was related to the prevailing mechanisms of defluoridation. Fluoride removal and sludge reduction were both favored by an initial pH around 4, but this value required an additional pre-treatment for pH adjustment. Finally, electric energy consumption was similar in both reactors when current density was lower than 12mA/cm(2), but mixing and complete flotation of the pollutants were achieved without additional mechanical power in the ELAR, using only the overall liquid recirculation induced by H(2) microbubbles generated by water electrolysis, which makes subsequent treatments easier to carry out.

  16. Removal of trace metal contaminants from potable water by electrocoagulation

    PubMed Central

    Heffron, Joe; Marhefke, Matt; Mayer, Brooke K.

    2016-01-01

    This study investigated the effects of four operational and environmental variables on the removal of trace metal contaminants from drinking water by electrocoagulation (EC). Removal efficiencies for five metals (arsenic, cadmium, chromium, lead and nickel) were compared under varying combinations of electrode material, post-treatment, water composition and pH. Iron electrodes out-performed aluminum electrodes in removing chromium and arsenic. At pH 6.5, aluminum electrodes were slightly more effective at removing nickel and cadmium, while at pH 8.5, iron electrodes were more effective for these metals. Regardless of electrode, cadmium and nickel removal efficiencies were higher at pH 8.5 than at pH 6.5. Post-EC treatment using membrane filtration (0.45 μm) enhanced contaminant removal for all metals but nickel. With the exception of lead, all metals exhibited poorer removal efficiencies as the ionic strength of the background electrolyte increased, particularly in the very high-solids synthetic groundwaters. Residual aluminum concentrations were lowest at pH 6.5, while iron residuals were lowest in low ionic strength waters. Both aluminum and iron residuals required post-treatment filtration to meet drinking water standards. EC with post-treatment filtration appears to effectively remove trace metal contaminants to potable water standards, but both reactor and source water parameters critically impact removal efficiency. PMID:27324564

  17. Transformation and removal of arsenic in groundwater by sequential anodic oxidation and electrocoagulation

    NASA Astrophysics Data System (ADS)

    Zhang, Peng; Tong, Man; Yuan, Songhu; Liao, Peng

    2014-08-01

    Oxidation of As(III) to As(V) is generally essential for the efficient remediation of As(III)-contaminated groundwater. The performance and mechanisms of As(III) oxidation by an as-synthesized active anode, SnO2 loaded onto Ti-based TiO2 nanotubes (Ti/TiO2NTs/Sb-SnO2), were investigated. The subsequent removal of total arsenic by electrocoagulation (EC) was further tested. The Ti/TiO2NTs/Sb-SnO2 anode showed a high and lasting electrochemical activity for As(III) oxidation. 6.67 μM As(III) in synthetic groundwater was completely oxidized to As(V) within 60 min at 50 mA. Direct electron transfer was mainly responsible at the current below 30 mA, while hydroxyl radicals contributed increasingly with the increase in the current above 30 mA. As(III) oxidation was moderately inhibited by the presence of bicarbonate (20 mM), while was dramatically increased with increasing the concentration of chloride (0-10 mM). After the complete oxidation of As(III) to As(V), total arsenic was efficiently removed by EC in the same reactor by reversing electrode polarity. The removal efficiency increased with increasing the current but decreased by the presence of phosphate and silica. Anodic oxidation represents an effective pretreatment approach to increasing EC removal of As(III) in groundwater under O2-limited conditions.

  18. The future for electrocoagulation as a localised water treatment technology.

    PubMed

    Holt, Peter K; Barton, Geoffrey W; Mitchell, Cynthia A

    2005-04-01

    Electrocoagulation is an electrochemical method of treating polluted water whereby sacrificial anodes corrode to release active coagulant precursors (usually aluminium or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles) at the cathode. Electrocoagulation has a long history as a water treatment technology having been employed to remove a wide range of pollutants. However electrocoagulation has never become accepted as a 'mainstream' water treatment technology. The lack of a systematic approach to electrocoagulation reactor design/operation and the issue of electrode reliability (particularly passivation of the electrodes over time) have limited its implementation. However recent technical improvements combined with a growing need for small-scale decentralised water treatment facilities have led to a re-evaluation of electrocoagulation. Starting with a review of electrocoagulation reactor design/operation, this article examines and identifies a conceptual framework for electrocoagulation that focuses on the interactions between electrochemistry, coagulation and flotation. In addition detailed experimental data are provided from a batch reactor system removing suspended solids together with a mathematical analysis based on the 'white water' model for the dissolved air flotation process. Current density is identified as the key operational parameter influencing which pollutant removal mechanism dominates. The conclusion is drawn that electrocoagulation has a future as a decentralised water treatment technology. A conceptual framework is presented for future research directed towards a more mechanistic understanding of the process.

  19. Synthetic wastewaters treatment by electrocoagulation to remove silver nanoparticles produced by different routes.

    PubMed

    Matias, M S; Melegari, S P; Vicentini, D S; Matias, W G; Ricordel, C; Hauchard, D

    2015-08-15

    Nanoscience is a field that has stood out in recent years. The accurate long-term health and environmental risks associated with these emerging materials are unknown. Therefore, this work investigated how to eliminate silver nanoparticles (AgNPs) from synthetic effluents by electrocoagulation (EC) due to the widespread use of this type of nanoparticle (NP) in industry and its potential inhibition power over microorganisms responsible for biological treatment in effluent treatment plants. Synthesized AgNPs were studied via four different routes by chemical reduction in aqueous solutions to simulate the chemical variations of a hypothetical industrial effluent, and efficiency conditions of the EC treatment were determined. All routes used silver nitrate as the source of silver ions, and two synthesis routes were studied with sodium citrate as a stabilizer. In route I, sodium citrate functioned simultaneously as the reducing agent and stabilizing agent, whereas route II used sodium borohydride as a reducing agent. Route III used D-glucose as the reducing agent and sodium pyrophosphate as the stabilizer; route IV used sodium pyrophosphate as the stabilizing agent and sodium borohydride as the reducing agent. The efficiency of the EC process of the different synthesized solutions was studied. For route I, after 85 min of treatment, a significant decrease in the plasmon resonance peak of the sample was observed, which reflects the efficiency in the mass reduction of AgNPs in the solution by 98.6%. In route II, after 12 min of EC, the absorbance results reached the detection limit of the measurement instrument, which indicates a minimum reduction of 99.9% of AgNPs in the solution. During the 4 min of treatment in route III, the absorbance intensities again reached the detection limit, which indicates a minimum reduction of 99.8%. In route IV, after 10 min of treatment, a minimum AgNP reduction of 99.9% was observed. Based on these results, it was possible to verify that the solutions containing citrate considerably increased the necessary times required to eliminate AgNPs from the synthesized effluent, whereas solutions free of this reagent showed better results on floc formation and, therefore, are best for the treatment. The elimination of AgNPs from effluents by EC proved effective for the studied routes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Inactivation of microbiota from urban wastewater by single and sequential electrocoagulation and electro-Fenton treatments.

    PubMed

    Anfruns-Estrada, Eduard; Bruguera-Casamada, Carmina; Salvadó, Humbert; Brillas, Enric; Sirés, Ignasi; Araujo, Rosa M

    2017-12-01

    This work aims at comparing the ability of two kinds of electrochemical technologies, namely electrocoagulation (EC) and electro-Fenton (EF), to disinfect primary and secondary effluents from municipal wastewater treatment plants. Heterotrophic bacteria, Escherichia coli, enterococci, Clostridium perfringens spores, somatic coliphages and eukaryotes (amoebae, flagellates, ciliates and metazoa) were tested as indicator microorganisms. EC with an Fe/Fe cell at 200 A m -2 and natural pH allowed >5 log unit removal of E. coli and final concentration below 1 bacteria mL -1 of coliphages and eukaryotes from both effluents in ca. 60 min, whereas heterotrophic bacteria, enterococci and spores were more resistant. A larger removal was obtained for the primary effluent, probably because the flocs remove higher amount of total organic carbon (TOC), entrapping more easily the microbiota. EF with a boron-doped diamond (BDD) anode and an air-diffusion cathode that produces H 2 O 2 on site was first performed at pH 3.0, with large or even total inactivation of microorganisms within 30 min. A more effective microorganism removal was attained as compared to EC thanks to • OH formed from Fenton's reaction. A quicker disinfection was observed for the secondary effluent owing to its lower TOC content, allowing the attack of greater quantities of electrogenerated oxidants on microorganisms. Wastewater disinfection by EF was also feasible at natural pH (∼7), showing similar abatement of active microorganisms as a result of the synergistic action of generated oxidants like active chlorine and coagulation with iron hydroxides. A sequential EC/EF treatment (30 min each) was more effective for a combined decontamination and disinfection of urban wastewater. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Transformation and removal of arsenic in groundwater by sequential anodic oxidation and electrocoagulation.

    PubMed

    Zhang, Peng; Tong, Man; Yuan, Songhu; Liao, Peng

    2014-08-01

    Oxidation of As(III) to As(V) is generally essential for the efficient remediation of As(III)-contaminated groundwater. The performance and mechanisms of As(III) oxidation by an as-synthesized active anode, SnO2 loaded onto Ti-based TiO2 nanotubes (Ti/TiO2NTs/Sb-SnO2), were investigated. The subsequent removal of total arsenic by electrocoagulation (EC) was further tested. The Ti/TiO2NTs/Sb-SnO2 anode showed a high and lasting electrochemical activity for As(III) oxidation. 6.67μM As(III) in synthetic groundwater was completely oxidized to As(V) within 60min at 50mA. Direct electron transfer was mainly responsible at the current below 30mA, while hydroxyl radicals contributed increasingly with the increase in the current above 30mA. As(III) oxidation was moderately inhibited by the presence of bicarbonate (20mM), while was dramatically increased with increasing the concentration of chloride (0-10mM). After the complete oxidation of As(III) to As(V), total arsenic was efficiently removed by EC in the same reactor by reversing electrode polarity. The removal efficiency increased with increasing the current but decreased by the presence of phosphate and silica. Anodic oxidation represents an effective pretreatment approach to increasing EC removal of As(III) in groundwater under O2-limited conditions. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Iron Polymerization and Arsenic Removal During In-Situ Iron Electrocoagulation in Synthetic Bangladeshi Groundwater

    NASA Astrophysics Data System (ADS)

    van Genuchten, C. M.; Pena, J.; Addy, S.; Gadgil, A.

    2010-12-01

    Millions of people worldwide are exposed to arsenic-contamination in groundwater drinking supplies. The majority of affected people live in rural Bangladesh. Electrocoagulation (EC) using iron electrodes is a promising arsenic removal strategy that is based on the generation of iron precipitates with a high affinity for arsenic through the electrochemical dissolution of a sacrificial iron anode. Many studies of iron hydrolysis in the presence of co-occurring ions in groundwater such as PO43-, SiO44-, and AsO43- suggest that these ions influence the polymerization and formation of iron oxide phases. However, the combined impact of these ions on precipitates generated by EC is not well understood. X-ray absorption spectroscopy (XAS) was used to examine EC precipitates generated in synthetic Bangladeshi groundwater (SBGW). The iron oxide structure and arsenic binding geometry were investigated as a function of EC operating conditions. As and Fe k-edge spectra were similar between samples regardless of the large range of current density (0.02, 1.1, 5.0, 100 mA/cm2) used during sample generation. This result suggests that current density does not play a large role in the formation EC precipitates in SBGW. Shell-by-shell fits of Fe K-edge data revealed the presence of a single Fe-Fe interatomic distance at approximately 3.06 Å. The absence of longer ranged Fe-Fe correlations suggests that EC precipitates consist of nano-scale chains (polymers) of FeO6 octahedra sharing equatorial edges. Shell-by-shell fits of As K-edge spectra show arsenic bound in primarily bidentate, binuclear corner sharing complexes. In this coordination geometry, arsenic prevents the formation of FeO6 corner-sharing linkages, which are necessary for 3-dimensional crystal growth. The individual and combined effects of other anions, such as PO43- and SiO44- present in SBGW are currently being investigated to determine the role of these ions in stunting crystal growth. The results provided by this study are useful in explaining the large adsorption capacity of EC precipitates. This study will also lead to better predictions of arsenic removal efficiency during EC and a better understanding of the long-term stability of arsenic-laden EC sludge.

  3. Decolorization of distillery spent wash effluent by electro oxidation (EC and EF) and Fenton processes: A comparative study.

    PubMed

    David, Charles; Arivazhagan, M; Tuvakara, Fazaludeen

    2015-11-01

    In this study, laboratory scale experiments were performed to degrade highly concentrated organic matter in the form of color in the distillery spent wash through batch oxidative methods such as electrocoagulation (EC), electrofenton (EF) and Fenton process. The effect of corresponding operating parameters, namely initial pH: 2-10; current intensity: 1-5A; electrolysis time: 0.5-4h; agitation speed: 100-500rpm; inter-electrode distance: 0.5-4cm and Fenton's reagent dosage: 5-40mg/L was employed for optimizing the process of spent wash color removal. The performance of all the three processes was compared and assessed in terms of percentage color removal. For EC, 79% color removal was achieved using iron electrodes arranged with 0.5cm of inter-electrode space and at optimum conditions of pH 7, 5A current intensity, 300rpm agitation speed and in 2h of electrolysis time. In EF, 44% spent wash decolorization was observed using carbon (graphite) electrodes with an optimum conditions of 0.5cm inter-electrode distance, pH 3, 4A current intensity, 20mg/L FeSO4 and agitation speed of 400rpm for 3h of electrolysis time. By Fenton process, 66% decolorization was attained by Fenton process at optimized conditions of pH 3, 40mg/L of Fenton's reagent and at 500rpm of agitation speed for 4h of treatment time. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Iron removal, energy consumption and operating cost of electrocoagulation of drinking water using a new flow column reactor.

    PubMed

    Hashim, Khalid S; Shaw, Andy; Al Khaddar, Rafid; Pedrola, Montserrat Ortoneda; Phipps, David

    2017-03-15

    The goal of this project was to remove iron from drinking water using a new electrocoagulation (EC) cell. In this research, a flow column has been employed in the designing of a new electrocoagulation reactor (FCER) to achieve the planned target. Where, the water being treated flows through the perforated disc electrodes, thereby effectively mixing and aerating the water being treated. As a result, the stirring and aerating devices that until now have been widely used in the electrocoagulation reactors are unnecessary. The obtained results indicated that FCER reduced the iron concentration from 20 to 0.3 mg/L within 20 min of electrolysis at initial pH of 6, inter-electrode distance (ID) of 5 mm, current density (CD) of 1.5 mA/cm 2 , and minimum operating cost of 0.22 US $/m 3 . Additionally, it was found that FCER produces H 2 gas enough to generate energy of 10.14 kW/m 3 . Statistically, it was found that the relationship between iron removal and operating parameters could be modelled with R 2 of 0.86, and the influence of operating parameters on iron removal followed the order: C 0 >t>CD>pH. Finally, the SEM (scanning electron microscopy) images showed a large number of irregularities on the surface of anode due to the generation of aluminium hydroxides. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  5. Fractional Factorial Design Study on the Performance of GAC-Enhanced Electrocoagulation Process Involved in Color Removal from Dye Solutions.

    PubMed

    Secula, Marius Sebastian; Cretescu, Igor; Cagnon, Benoit; Manea, Liliana Rozemarie; Stan, Corneliu Sergiu; Breaban, Iuliana Gabriela

    2013-07-10

    The aim of this study was to determine the effects of main factors and interactions on the color removal performance from dye solutions using the electrocoagulation process enhanced by adsorption on Granular Activated Carbon (GAC). In this study, a mathematical approach was conducted using a two-level fractional factorial design ( FFD ) for a given dye solution. Three textile dyes: Acid Blue 74, Basic Red 1, and Reactive Black 5 were used. Experimental factors used and their respective levels were: current density (2.73 or 27.32 A/m²), initial pH of aqueous dye solution (3 or 9), electrocoagulation time (20 or 180 min), GAC dose (0.1 or 0.5 g/L), support electrolyte (2 or 50 mM), initial dye concentration (0.05 or 0.25 g/L) and current type (Direct Current- DC or Alternative Pulsed Current- APC ). GAC-enhanced electrocoagulation performance was analyzed statistically in terms of removal efficiency, electrical energy, and electrode material consumptions, using modeling polynomial equations. The statistical significance of GAC dose level on the performance of GAC enhanced electrocoagulation and the experimental conditions that favor the process operation of electrocoagulation in APC regime were determined. The local optimal experimental conditions were established using a multi-objective desirability function method.

  6. Fractional Factorial Design Study on the Performance of GAC-Enhanced Electrocoagulation Process Involved in Color Removal from Dye Solutions

    PubMed Central

    Secula, Marius Sebastian; Cretescu, Igor; Cagnon, Benoit; Manea, Liliana Rozemarie; Stan, Corneliu Sergiu; Breaban, Iuliana Gabriela

    2013-01-01

    The aim of this study was to determine the effects of main factors and interactions on the color removal performance from dye solutions using the electrocoagulation process enhanced by adsorption on Granular Activated Carbon (GAC). In this study, a mathematical approach was conducted using a two-level fractional factorial design (FFD) for a given dye solution. Three textile dyes: Acid Blue 74, Basic Red 1, and Reactive Black 5 were used. Experimental factors used and their respective levels were: current density (2.73 or 27.32 A/m2), initial pH of aqueous dye solution (3 or 9), electrocoagulation time (20 or 180 min), GAC dose (0.1 or 0.5 g/L), support electrolyte (2 or 50 mM), initial dye concentration (0.05 or 0.25 g/L) and current type (Direct Current—DC or Alternative Pulsed Current—APC). GAC-enhanced electrocoagulation performance was analyzed statistically in terms of removal efficiency, electrical energy, and electrode material consumptions, using modeling polynomial equations. The statistical significance of GAC dose level on the performance of GAC enhanced electrocoagulation and the experimental conditions that favor the process operation of electrocoagulation in APC regime were determined. The local optimal experimental conditions were established using a multi-objective desirability function method. PMID:28811405

  7. A novel combined electrochemical-magnetic method for water treatment.

    PubMed

    Ibanez, Jorge G; Vazquez-Olavarrieta, Jorge Luis; Hernandez-Rivera, Lydia; Garcia-Sanchez, Martin Adolfo; Garcia-Pintor, Elizabeth

    2012-01-01

    Electrocoagulation (EC) is a wastewater treatment process in which aqueous pollutants can be removed by adsorption, entrapment, precipitation or coalescence during a coagulation step produced by electrochemically generated metallic species. When using Fe as the sacrificial electrode, Fe(2+) and Fe(3+) ions are formed. As Fe(3+) species are paramagnetic, this property can in principle be used to facilitate their removal through the application of a magnetic field. In the present work we present a proof-of-concept for a combined electrochemical-magnetic method for pollutant removal. For this approach, the amounts of Fe(2+) and Fe(3+) produced in an EC cell at various voltages were measured by spectroscopic methods to confirm that Fe(3+) species predominate (up to 84%). The effectiveness of the presence of a magnetic field in the precipitation of coagulants from a suspension was confirmed by monitoring the turbidity change versus time with and without exposure to a magnetic field, up to a 30% improvement.

  8. Defluoridation of drinking water using a new flow column-electrocoagulation reactor (FCER) - Experimental, statistical, and economic approach.

    PubMed

    Hashim, Khalid S; Shaw, Andy; Al Khaddar, Rafid; Ortoneda Pedrola, Montserrat; Phipps, David

    2017-07-15

    A new batch, flow column electrocoagulation reactor (FCER) that utilises a perforated plate flow column as a mixer has been used to remove fluoride from drinking water. A comprehensive study has been carried out to assess its performance. The efficiency of fluoride removal (R%) as a function of key operational parameters such as initial pH, detention time (t), current density (CD), inter-electrode distance (ID) and initial concentration (C 0 ) has been examined and an empirical model has been developed. A scanning electron microscopy (SEM) investigation of the influence of the EC process on morphology of the surface of the aluminium electrodes, showed the erosion caused by aluminium loss. A preliminary estimation of the reactor's operating cost is suggested, allowing for the energy from recycling of hydrogen gas hydrogen gas produced amount. The results obtained showed that 98% of fluoride was removed within 25 min of electrolysis at pH of 6, ID of 5 mm, and CD of 2 mA/cm 2 . The general relationship between fluoride removal and operating parameters could be described by a linear model with R 2 of 0.823. The contribution of the operating parameters to the suggested model followed the order: t > CD > C 0  > ID > pH. The SEM images obtained showed that, after the EC process, the surface of the anodes, became non-uniform with a large number of irregularities due to the generation of aluminium hydroxides. It is suggested that these do not materially affect the performance. A provisional estimate of the operating cost was 0.379 US $/m 3 . Additionally, it has been found that 0.6 kW/m 3 is potentially recoverable from the H 2 gas. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  9. Concurrent arsenic and microbe removal from groundwater using iron electro-coagulation: Mechanisms of E.coli attenuation

    NASA Astrophysics Data System (ADS)

    Delaire, C.; Van Genuchten, C. M.; Amrose, S. E.; Gadgil, A.

    2013-12-01

    Around 60 million people in South Asia drink groundwater from arsenic contaminated shallow aquifers. Research over the last two decades has focused on arsenic removal alone to mitigate this problem, largely ignoring possible microbial contamination of shallow groundwater. However, diarrheal diseases are still prevalent in the region and recently, fecal indicators and pathogens were detected in shallow tubewells in Bangladesh. Comprehensive treatment technologies addressing both microbial and arsenic contamination are needed and may have a higher social acceptability, contributing to their sustainability in resource poor areas. Iron electro-coagulation (EC) is a low-cost and low-waste process using small amounts of electricity to produce Fe(III)-oxides that serve as an adsorbent for arsenic and a coagulant for microbes. Iron EC relies on the oxidative dissolution of a Fe(0) anode to produce Fe(II) ions that rapidly oxidize and precipitate in the presence of oxygen. In the process, strong oxidants generated by Fenton-like reactions convert As(III) into As(V), which is more amenable to adsorption. In this work, we demonstrate that iron EC can simultaneously remove arsenic and the model organism E.coli in South Asian synthetic groundwater. We find that E.coli is attenuated because it adheres to iron precipitates and is trapped in aggregates that settle out. Some inactivation (~20%, as probed by membrane permeability stains) also takes place, likely due to oxidative stress caused by strong oxidants produced in Fenton-like reactions. We find that pH has a significant effect on E.coli removal from South Asian synthetic groundwater. The iron dosages required to achieve 4-log attenuation (from an initial concentration of 10^6.4 CFU/mL) at pH 6.6. and 7.5 are 25 and 140 mg-Fe/L respectively, other parameters being equal. In this pH range, iron precipitates generated in synthetic groundwater have a negative surface charge, whose variation cannot entirely explain the sensitivity of bacterial attenuation to pH. We propose an alternative explanation involving Fe(II) oxidation rate. We use TEM and ATR-FTIR spectroscopy to investigate how E.coli binds to EC-precipitates. TEM enables identifying where iron particles are located with respect to the cell surface (e.g. in EPS at a distance from the cell, on the cell surface, or inside the periplasm). Analysis of ATR-FTIR spectra in the mid-IR region (800 to 1700 cm-1) allows detection of possible covalent bonds between carboxyl or phosphate residues on the cell wall and EC-precipitates. We build on these results to discuss the strength and robustness of attachment.

  10. The decolorization and mineralization of acid orange 6 azo dye in aqueous solution by advanced oxidation processes: a comparative study.

    PubMed

    Hsing, Hao-Jan; Chiang, Pen-Chi; Chang, E-E; Chen, Mei-Yin

    2007-03-06

    The comparison of different advanced oxidation processes (AOPs), i.e. ultraviolet (UV)/TiO(2), O(3), O(3)/UV, O(3)/UV/TiO(2), Fenton and electrocoagulation (EC), is of interest to determine the best removal performance for the destruction of the target compound in an Acid Orange 6 (AO6) solution, exploring the most efficient experimental conditions as well; on the other hand, the results may provide baseline information of the combination of different AOPs in treating industrial wastewater. The following conclusions can be drawn: (1) in the effects of individual and combined ozonation and photocatalytic UV irradiation, both O(3)/UV and O(3)/UV/TiO(2) processes exhibit remarkable TOC removal capability that can achieve a 65% removal efficiency at pH 7 and O(3) dose=45mg/L; (2) the optimum pH and ratio of [H(2)O(2)]/[Fe(2+)] found for the Fenton process, are pH 4 and [H(2)O(2)]/[Fe(2+)]=6.58. The optimum [H(2)O(2)] and [Fe(2+)] under the same HF value are 58.82 and 8.93mM, respectively; (3) the optimum applied voltage found in the EC experiment is 80V, and the initial pH will affect the AO6 and TOC removal rates in that acidic conditions may be favorable for a higher removal rate; (4) the AO6 decolorization rate ranking was obtained in the order of O(3)

  11. Optimizing COD removal from greywater by photoelectro-persulfate process using Box-Behnken design: assessment of effluent quality and electrical energy consumption.

    PubMed

    Ahmadi, Mehdi; Ghanbari, Farshid

    2016-10-01

    Greywater (GW) is a potential source for water reuse in various applications. However, GW treatment is still a vital issue in water reuse in cases of environmental standards and risk to public health. This study investigates optimization and modeling of a hybrid process for COD removal from GW. Persulfate (PS) was simultaneously activated by electrogenerated ferrous ion (EC) and UV to generate sulfate radical. Photoelectro-persulfate (PEPS) was optimized by Box-Behnken design and the effects of four variables (pH, PS dosage, current density, and electrolysis time) were evaluated on COD removal. The results and several coefficients showed that the obtained model was acceptable for predicting the COD removal. Moreover, under optimum conditions (pH = 6.9, PS = 8.8 mM, current density = 2.0 mA/cm(2), and 49.3 min electrolysis time), BOD5, turbidity, TSS, phosphate, and UV254 were effectively removed and COD and BOD5 values reached to discharge standards. Different configurations of the processes were assessed for COD removal. The order of COD removal efficiency followed: PS < Fe(II) < UV/PS ≤ Fe(II)/PS < Fe(II)/PS/UV < electrocoagulation ≤ electrocoagulation/UV < electro-PS < PEPS. The monitoring PS concentration during 60 min reaction time in the aforesaid processes indicated that PEPS could remarkably activate PS. The solution pH was also monitored and related results revealed that the presence of PS during the 10 min first time decreased pH value while production of hydroxide ion at cathode increased pH significantly. Finally, the contribution of electrochemical process in the electrical energy consumption was far less than that of photolysis process in hybrid PEPS process.

  12. Organics removal in oily bilgewater by electrocoagulation process.

    PubMed

    Asselin, Mélanie; Drogui, Patrick; Brar, Satinder Kaur; Benmoussa, Hamel; Blais, Jean-François

    2008-03-01

    This study investigated the treatment of oily bilgewater using an electrocoagulation technique. Electrocoagulation process was evaluated at laboratory scale (1.7 l electrolytic cell) and involved utilization of two kinds of electrodes (iron and aluminium) arranged either in bipolar (BP) or monopolar (MP) configuration. Results showed that the best performance was obtained using mild steel MP electrode system operated at a current intensity of 1.5A, through 60 or 90 min of treatment. Under these conditions, removal yields of 93.0+/-3.3% and 95.6+/-0.2% were measured for BOD and O&G, respectively, whereas CODs and CODt were removed by 61.3+/-3.6% and 78.1+/-0.1%, respectively. Likewise, 99.4+/-0.1% of n-C10 to n-C50 hydrocarbons was removed from oily bilgewater. Electrocoagulation was also efficient for clarification of OBW. Removal yields of 99.8+/-0.4% and 98.4+/-0.5% have been measured for TSS and turbidity, respectively. Electrocoagulation process operated under the optimal conditions involves a total cost of 0.46 US$ per cubic meter of treated OBW. This cost only includes energy and electrode consumptions, chemicals, and sludge disposal.

  13. Landfill Leachate Treatment by Electrocoagulation and Fiber Filtration.

    PubMed

    Li, Runwei; Wang, Boya; Owete, Owete; Dertien, Joe; Lin, Chen; Ahmad, Hafiz; Chen, Gang

    2017-11-01

      Landfilling is widely adopted as one of the most economical processes for solid waste disposal. At the same time, landfill leachate is also a great environmental concern owing to its complex composition and high concentrations of contaminants. This research investigated electrocoagulation and fiber filtration for the treatment of landfill leachate. Besides electrical current (i.e., current density) and reaction time, pH played a very important role in arsenic and phosphorus removal by electrocoagulation. The combination of electrocoagulation with fiber filtration achieved a 94% chemical oxygen demand (COD), 87% arsenic, 96% iron, and 86% phosphorus removal. During electrocoagulation, the micro-particles that could not be settled by gravity were removed by the first stage of fiber filtration. Organic contaminants in the leachate were further removed by biodegradation in the second stage of fiber biofiltration.

  14. Treatment of textile wastewater by a hybrid electrocoagulation/nanofiltration process.

    PubMed

    Aouni, Anissa; Fersi, Cheïma; Ben Sik Ali, Mourad; Dhahbi, Mahmoud

    2009-09-15

    Untreated effluents from textile industries are usually highly coloured and contain a considerable amount of contaminants and pollutants. Stringent environmental regulation for the control of textile effluents is enforced in several countries. Previous studies showed that many techniques have been used for the treatment of textile wastewater, such as adsorption, biological treatment, oxidation, coagulation and/or flocculation, among them coagulation is one of the most commonly used techniques. Electrocoagulation is a process consisting in creating metallic hydroxide flocks within the wastewater by the electrodissolution of soluble anodes, usually made of iron or aluminium. This method has been practiced for most of the 20th century with limited success. In recent years, however, it started to regain importance with the progress of the electrochemical processes and the increase in environmental restrictions in effluent wastewater. This paper examines the use of electrocoagulation treatment process followed by nanofiltration process of a textile effluent sample. The electrocoagulation process was studied under several conditions such as various current densities and effect of experimental tense. Efficiencies of COD and turbidity reductions and colour removal were studied for each experiment. The electrochemical treatment was indented primarily to remove colour and COD of wastewater while nanofiltration was used to further improve the removal efficiency of the colour, COD, conductivity, alkalinity and total dissolved solids (TDS). The experimental results, throughout the present study, have indicated that electrocoagulation treatment followed by nanofiltration processes were very effective and were capable of elevating quality of the treated textile wastewater effluent.

  15. Comparative study on the removal of COD from POME by electrocoagulation and electro-Fenton methods: Process optimization

    NASA Astrophysics Data System (ADS)

    Chairunnisak, A.; Arifin, B.; Sofyan, H.; Lubis, M. R.; Darmadi

    2018-03-01

    This research focuses on the Chemical Oxygen Demand (COD) treatment in palm oil mill effluent by electrocoagulation and electro-Fenton methods to solve it. Initially, the aqueous solution precipitates in acid condition at pH of about two. This study focuses on the palm oil mill effluent degradation by Fe electrodes in a simple batch reactor. This work is conducted by using different parameters such as voltage, electrolyte concentration of NaCl, volume of H2O2 and operation time. The processing of data resulted is by using response surface method coupled with Box-Behnken design. The electrocoagulation method results in the optimum COD reduction of 94.53% from operating time of 39.28 minutes, 20 volts, and without electrolyte concentration. For electro-Fenton process, experiment points out that voltage 15.78 volts, electrolyte concentration 0.06 M and H2O2 volume 14.79 ml with time 35.92 minutes yield 99.56% degradation. The result concluded that the electro-Fenton process was more effective to degrade COD of the palm-oil-mill effluent compared to electrocoagulation process.

  16. Electrocoagulation mechanism of perfluorooctanoate (PFOA) on a zinc anode: Influence of cathodes and anions.

    PubMed

    Wang, Yujuan; Lin, Hui; Jin, Fangyuan; Niu, Junfeng; Zhao, Jinbo; Bi, Ying; Li, Ying

    2016-07-01

    Batch experiments were conducted to investigate the effects of cathode materials and anions (Cl(-), SO4(2-), NO3(-), and CO3(2-)/HCO3(-)) on perfluorooctanoate (PFOA) removal in electrocoagulation process using zinc anode. The results indicated that the hydroxide flocs generated in-situ in the electrocoagulation process using the stainless steel rod as cathode were more effective than those using aluminum rod as cathode for the removal of PFOA after 20min of electrocoagulation at a current density of 0.5mAcm(-2). Hydroxide flocs generated in-situ in the electrocoagulation in the presence of Cl(-)/NO3(-) could effectively remove PFOA from aqueous solution with the removal ratios of 99.7%/98.1% and 98.9%/97.3% using stainless steel rod and aluminum rod as cathode, respectively. However, the PFOA removal ratios were 96.2%/4.1% and 7.4%/4.6% using stainless steel rod and aluminum rod as cathode, respectively, in the presence of SO4(2-) and CO3(2-)/HCO3(-). The different removal ratios of PFOA during the electrocoagulation process were primarily due to the fact that the hydroxide flocs generated in-situ were different in the presence of diverse cathodes and anions. We firstly demonstrated that Zn0.70Al0.30(OH)2(CO3)0.15·xH2O and ZnO generated in-situ in the electrocoagulation process (except for CO3(2-)/HCO3(-)) using zinc anode and aluminum/stainless steel rod cathode governed the sorption of PFOA. The adsorbent hydroxide flocs in-situ generated in the presence of Cl(-) could effectively remove PFOA from aqueous solution containing CO3(2-)/HCO3(-) anion at the initial hydroxide flocs concentration of 2000mgL(-1). These results provided an effective and alternative method to remove PFOA from aqueous solution containing CO3(2-)/HCO3(-) anion. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Treatment of laundry wastewater by biological and electrocoagulation methods.

    PubMed

    Ramcharan, Terelle; Bissessur, Ajay

    2017-01-01

    The present study describes an improvement in the current electrocoagulation treatment process and focuses on a comparative study for the clean-up of laundry wastewater (LWW) after each wash and rinse cycle by biological and electrocoagulation treatment methods. For biological treatment, the wastewater was treated with a Bacillus strain of aerobic bacteria especially suited for the degradation of fats, lipids, protein, detergents and hydrocarbons. Treatment of the LWW by electrocoagulation involved the oxidation of aluminium metal upon the application of a controlled voltage which produces various aluminium hydroxy species capable of adsorbing pollutants from the wastewater. The efficiency of the clean-up of LWW using each method was assessed by determination of surfactant concentration, chemical oxygen demand and total dissolved solids. A rapid decrease in surfactant concentration was noted within 0.5 hour of electrocoagulation, whereas a notable decrease in the surfactant concentration was observed only after 12 hour of biological treatment. The rapid generation of aluminium hydroxy species in the electrocoagulation cell allowed adsorption of pollutants at a faster rate when compared to the aerobic degradation of the surfactant; hence a reduced period of time is required for treatment of LWW by electrocoagulation.

  18. Landfill leachate sludge use as soil additive prior and after electrocoagulation treatment: A cytological assessment using CHO-k1 cells.

    PubMed

    Morozesk, M; Bonomo, M M; Rocha, L D; Duarte, I D; Zanezi, E R L; Jesus, H C; Fernandes, M N; Matsumoto, S T

    2016-09-01

    Electrocoagulation has recently attracted attention as a potential technique for treating toxic effluents due to its versatility and environmental compatibility, generating a residue chemically suitable to be used as a soil additive. In the present study, landfill leachate sludge hazardous effects were investigated prior and after electrocoagulation process using in vitro assays with the mammalian cells CHO-k1. An integrated strategy for risk assessment was used to correctly estimate the possible adverse landfill leachate sludge effects on human health and ecosystem. Electrocoagulation process proved to be an effective treatment due to possibility to improve effluent adverse characteristics and produce sludge with potential to be used as soil additive. Despite low cytoxicity, the residue presented genotoxic and mutagenic effects, indicating a capacity to induce genetic damages, probably due to induction of polyploidization process in cells. The observed effects demand an improvement of waste management methods for reduce negative risks of landfill leachate sludge application. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Detoxification of olive mill wastewater by electrocoagulation and sedimentation processes.

    PubMed

    Khoufi, Sonia; Feki, Firas; Sayadi, Sami

    2007-04-02

    Olive mill wastewater (OMW) is characterised by its high suspended solids content (SS), high turbidity (NTU), chemical oxygen demand (COD) concentration up to 100 gl(-1) and toxic phenolic compounds concentration up to 10 gl(-1). This study examined the effect of a physico-electrochemical method to detoxify olive mill wastewater prior an anaerobic biotreatment process. The proposed pre-treatment process consisted in a preliminary electrocoagulation step in which most phenolic compounds were polymerised, followed by a sedimentation step. The BOD(5)/COD ratio of the electrocoagulated OMW increased from 0.33, initial value, to 0.58. Furthermore, the sedimentation step yielded the removal of 76.2%, 75% and 71% of phenolic compounds, turbidity and suspended solid, respectively, after 3 days of plain settling. The combination of electrocoagulation and sedimentation allowed a COD reduction and decoloration of about 43% and 90%, respectively. This pre-treatment decreases the inhibition of Vibrio fisheri luminescence by 66.4%. Continuous anaerobic biomethanization experiments conducted in parallel with raw OMW and electrocoagulated OMW before and after sedimentation at a loading rate of 6g COD l(-1)day(-1), proved that the final pre-treated OMW was bioconverted into methane at high yield while raw OMW was very toxic to anaerobic microorganisms.

  20. Removal of veterinary antibiotics from wastewater by electrocoagulation.

    PubMed

    Baran, Wojciech; Adamek, Ewa; Jajko, Marcin; Sobczak, Andrzej

    2018-03-01

    The aim of this study was to assess the effectiveness of veterinary antibiotic removal from wastewater using an electrocoagulation method. The removal efficiency of ampicillin, doxycycline, sulfathiazole and tylosin; the antibiotic degradation degree after electrolysis; and the toxicity and qualitative composition of antibiotic solutions after electrocoagulation were determined in the experiments. HPLC-QTOF was used for quantitative and qualitative determination. The eco-toxicity was assessed using the MARA ® assay. After electrocoagulation, the concentration of ampicillin, doxycycline, sulfathiazole and tylosin in wastewater decreased 3.6 ± 3.2%, ∼100%, 3.3 ± 0.4% and 3.1 ± 0.3%, respectively. Doxycycline was the only antibiotic effectively removed from wastewater during electrocoagulation. Simultaneously, part of this antibiotic underwent oxidative degradation. As a result of this process, the eco-toxicity in the reaction environment decreased. Copyright © 2017. Published by Elsevier Ltd.

  1. ETV REPORT AND VERIFICATION STATEMENT - KASELCO POSI-FLO ELECTROCOAGULATION TREATMENT SYSTEM

    EPA Science Inventory

    The Kaselco Electrocoagulation Treatment System (Kaselco system) in combination with an ion exchange polishing system was tested, under actual production conditions, processing metal finishing wastewater at Gull Industries in Houston, Texas. The verification test evaluated the a...

  2. Experimental studies on the enhanced performance of lightweight oil recovery using a combined electrocoagulation and magnetic field processes.

    PubMed

    Liu, Yang; Yang, Jie; Jiang, Wenming; Chen, Yimei; Yang, Chaojiang; Wang, Tianyu; Li, Yuxing

    2018-08-01

    On marine oil spill, inflammable lightweight oil has characteristics of explosion risk and contamination of marine enviroment, therefore treatment of stable emulsion with micron oil droplets is urgent. This study aimed to propose a combined electrocoagulation and magnetic field processes to enhance performance of lightweight oil recovery with lower energy consumption. The effects of current density, electrolysis time, strength and direction of magnetic field on the overall treatment efficiency of the reactor were explored. Furthermore, the comparison between coupling device and only electrocoagulation through tracking oil removal in nine regions between the electrodes. The results were shown that the permanent magnets applied was found to enhance demulsification process within electrocoagulation reactor. For a given current density of 60 A m -2 at 16 min, Lorentz force downward was proved to promote the sedimentation of coagulants. As the magnetic field strength increases from 20 to 60 mT, oil removal efficiency was observed to increase and then decrease, and simultaneously energy consumption reduced and then present constantly. The results were found that the magnetic field strength of 40 mT was optimal within electrocoagulation reactor, which can not only diminishe difference of mass transfer rate along the height of vertical plate but also consume lowest energy. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Complexing agent and heavy metal removals from metal plating effluent by electrocoagulation with stainless steel electrodes.

    PubMed

    Kabdaşli, Işik; Arslan, Tülin; Olmez-Hanci, Tuğba; Arslan-Alaton, Idil; Tünay, Olcay

    2009-06-15

    In the present study, the treatability of a metal plating wastewater containing complexed metals originating from the nickel and zinc plating process by electrocoagulation using stainless steel electrodes was experimentally investigated. The study focused on the effect of important operation parameters on electrocoagulation process performance in terms of organic complex former, nickel and zinc removals as well as sludge production and specific energy consumption. The results indicated that increasing the applied current density from 2.25 to 9.0 mA/cm(2) appreciably enhanced TOC removal efficiency from 20% to 66%, but a further increase in the applied current density to 56.25 mA/cm(2) did not accelerate TOC removal rates. Electrolyte concentration did not affect the process performance significantly and the highest TOC reduction (66%) accompanied with complete heavy metal removals were achieved at the original chloride content ( approximately 1500 mg Cl/L) of the wastewater sample. Nickel removal performance was adversely affected by the decrease of initial pH from its original value of 6. Optimum working conditions for electrocoagulation of metal plating effluent were established as follows: an applied current density of 9 mA/cm(2), the effluent's original electrolyte concentration and pH of the composite sample. TOC removal rates obtained for all electrocoagulation runs fitted pseudo-first-order kinetics very well (R(2)>92-99).

  4. Slaughterhouse Wastewater Treatment by Combined Chemical Coagulation and Electrocoagulation Process

    PubMed Central

    Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein

    2012-01-01

    Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD5 removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater. PMID:22768233

  5. Slaughterhouse wastewater treatment by combined chemical coagulation and electrocoagulation process.

    PubMed

    Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein

    2012-01-01

    Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD(5) removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.

  6. Combined process of electrocoagulation and photocatalytic degradation for the treatment of olive washing wastewater.

    PubMed

    Ates, Hasan; Dizge, Nadir; Yatmaz, H Cengiz

    2017-01-01

    In this study, an electrocoagulation reactor (ECR) and photocatalytic reactor (PCR) were tested to understand the performance of combined electrocoagulation and photocatalytic-degradation of olive washing wastewater (OWW). The effects of initial pH (6.0, 6.9, 8.0, 9.0), applied voltage (10.0, 12.5, 15.0 V), and operating time (30, 60, 90, 120 min) were investigated in the electrocoagulation reactor when aluminum electrodes were used as both anode and cathode. The pH, conductivity, color, chemical oxygen demand (COD), and phenol were measured versus time to determine the efficiency of the ECR and PCR process. It was observed that electrocoagulation as a single treatment process supplied the COD removal of 62.5%, color removal of 98.1%, and total phenol removal of 87% at optimum conditions as pH 6.9, applied voltage of 12.5 V, and operating time of 120 min. Moreover, final pH and conductivity were 7.7 and 980 μS/cm, respectively. On the other hand, the effect of semiconductor catalyst type (TiO 2 and ZnO) and loading (1, 2, 3 g/L) were tested using PCR as a stand-alone technique. It was found that photocatalytic degradation as a single treatment process when using 1 g/L ZnO achieved the COD removal of 46%, color removal of 99% with a total phenol removal of 41% at optimum conditions. Final pH and conductivity were 6.2 and 915 μS/cm, respectively. Among semiconductor catalysts, TiO 2 and ZnO performed identical efficiencies for both COD and total phenol removal. Moreover, combination in which electrochemical degradation was employed as a pre-treatment to the photocatalytic degradation process obtained high COD removal of 88% and total phenol, as well as color removal of 100% for the OWW. The electrochemical treatment alone was not effective, but in combination with the photocatalytic process, led to a high-quality effluent. Finally, sludge collected from the electrocoagulation process was characterized by attenuated total reflection Fourier transform infrared and X-ray powder diffraction analyses.

  7. A new multiple-stage electrocoagulation process on anaerobic digestion effluent to simultaneously reclaim water and clean up biogas.

    PubMed

    Liu, Zhiguo; Stromberg, David; Liu, Xuming; Liao, Wei; Liu, Yan

    2015-03-21

    A new multiple-stage treatment process was developed via integrating electrocoagulation with biogas pumping to simultaneously reclaim anaerobic digestion effluent and clean up biogas. The 1st stage of electrocoagulation treatment under the preferred reaction condition led to removal efficiencies of 30%, 81%, 37% and >99.9% for total solids, chemical oxygen demand, total nitrogen and total phosphorus, respectively. Raw biogas was then used as a reactant and pumped into the effluent to simultaneously neutralize pH of the effluent and remove H2S in the biogas. The 2nd stage of electrocoagulation treatment on the neutralized effluent showed that under the selected reaction condition, additional 60% and 10% of turbidity and chemical oxygen demand were further removed. The study concluded a dual-purpose approach for the first time to synergistically combine biogas purification and water reclamation for anaerobic digestion system, which well addresses the downstream challenges of anaerobic digestion technology. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Batch leachate treatment using stirred electrocoagulation reactor with variation of residence time and stirring rate

    NASA Astrophysics Data System (ADS)

    Sitorus, I. S.; Astono, W.; Iswanto, B.

    2018-01-01

    This study aims to reduce pollutant levels of the leachate by electrocoagulation method using a stirred electrocoagulation reactor as the electrochemical water treatment. The release of active coagulants as metallic ions took place in the anode, while in the cathode, the electrolysis reaction in the form of hydrogen gas dischargeoccurred. The source of wastewater is Waste Water Treatment Plant inlet III of Bantar Gebang, Bekasi. Some parameters were analyzed in this research, i.e., Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), NH3, NO3 -, NO2 -, N-total, and organic substances as well as the microorganism growth before and after electrocoagulation, with variations of detention time (seconds) of 10, 20, 120, 600 and rapid mixing conditions (rpm) of 60, 100 and 200. The results show that the greater the rapid mixing speed and the detention time of electrolysis, the higher the removal of contaminants in liquid waste. The optimum condition of electrocoagulation was encountered at 200 rpm rapid mixing with 600 seconds of processing time. The removal efficiencies of electrocoagulation method for each parameter are TSS of 46.80%, BOD5 of 71.33%, COD of 73.77%, Pb of 62.5%,and NH3-N of 57.92%,whereas the pH value has been increased from 8.03 to 8.95. The electrocoagulation method can reduce levels of pollutants, complying with the environmental standards.

  9. A combined electrocoagulation-electrooxidation treatment for industrial wastewater.

    PubMed

    Linares-Hernández, Ivonne; Barrera-Díaz, Carlos; Bilyeu, Bryan; Juárez-GarcíaRojas, Pablo; Campos-Medina, Eduardo

    2010-03-15

    This study addresses the elimination of persistent organic compounds in industrial wastewater using a synergistic combination of electrocoagulation and electrooxidation. Electrocoagulation is a relatively quick process (30 min), which is very effective in removing colloidal and suspended particles, as seen in changes in coliforms, turbidity, and color and in the general absorbance by UV-vis spectroscopy. However, it is relatively ineffective in eliminating stable persistent organic compounds--in this work, only half of the COD was eliminated from wastewater and an oxidation peak in the cyclic voltammetry scan remained. Electrooxidation is very effective in breaking down organic compounds through oxidation as reflected in the elimination of COD, BOD(5), and oxidative peak in cyclic voltammetry, but requires so much time (21 h) that it has very limited practicality, especially when colloidal and suspended particles are present. Electrooxidative mineralization of electrocoagulated wastewater, in which most of the colloids and charged species have been removed, takes less than 2h. In the coupled technique, electrocoagulation quickly coagulates and removes the colloidal and suspended particles, as well as many charged species, then electrooxidation oxidizes the remaining organics. The coupled process eliminates COD, BOD(5), color, turbidity, and coliforms in a practical amount of time (2h). (c) 2009 Elsevier B.V. All rights reserved.

  10. Removal Efficiency of Electrocoagulation Treatment Using Aluminium Electrode for Stabilized Leachate

    NASA Astrophysics Data System (ADS)

    Mohamad Zailani, L. W.; Amdan, N. S. Mohd; Zin, N. S. M.

    2018-04-01

    This research was conducted to investigate the performance of aluminium electrode in electrocoagulation process removing chemical oxygen demand (COD), ammonia, turbidity, colour and suspended solid (SS) from Simpang Renggam landfill leachate. Effects of current density, electrolysis duration and pH were observed in this study. From the data obtained, optimum condition at current density was recorded at 200 A/m2with the electrolysis duration of 20-minutes and optimum pH value at 4. The removal recorded at this condition for COD, ammonia, colour, turbidity and suspended solid were 60%, 37%, 94%, 88% and 89% respectively. Electrocoagulation treatment give a better result and can be applied for leachate treatment in future. Thus, electrocoagulation treatment has the potential to be used in treatment of leachate.

  11. Optimizing electrocoagulation process using experimental design for COD removal from unsanitary landfill leachate.

    PubMed

    Ogedey, Aysenur; Tanyol, Mehtap

    2017-12-01

    Leachate is the most difficult wastewater to be treated due to its complex content and high pollution release. For this reason, since it is not possible to be treated with a single process, a pre-treatment is needed. In the present study, a batch electrocoagulation reactor containing aluminum and iron electrodes was used to reduce chemical oxygen demand (COD) from landfill leachate (Tunceli, Turkey). Optimization of COD elimination was carried out with response surface methodology to describe the interaction effect of four main process independent parameters (current density, inter-electrode distance, pH and time of electrolysis). The optimum current density, inter-electrode distance, pH and time of electrolysis for maximum COD removal (43%) were found to be 19.42 mA/m 2 , 0.96 cm, 7.23 and 67.64 min, respectively. The results shown that the electrocoagulation process can be used as a pre-treatment step for leachate.

  12. Structure of Fe(III) precipitates generated by Fe(0) electrocoagulation in the presence of groundwater ions

    NASA Astrophysics Data System (ADS)

    van Genuchten, C. M.; Pena, J.; Addy, S. E.; Gadgil, A. J.

    2012-12-01

    Electrocoagulation (EC) using Fe(0) electrodes is an inexpensive and efficient technology capable of removing a variety of contaminants from water supplies. Because of its ease of use and modest electricity and Fe(0) requirements, EC has potential as an arsenic-removal technology for rural South Asia, where millions drink groundwater contaminated by arsenic. In EC, a small external voltage applied to a sacrificial Fe(0) anode in contact with an electrolyte (e.g. pumped groundwater containing arsenic) promotes the oxidative dissolution of Fe ions, which polymerize and create reactive hydrous ferric oxides (HFO) in-situ with a high affinity for binding contaminants. The chemical composition of the electrolyte influences EC performance. For example, major inorganic ions present in groundwater (e.g. Ca, Mg, P, As(V), Si) alter the pathway by which FeO6 oligomers polymerize to form crystalline Fe (oxyhydr)oxide minerals. Because the precipitate structure largely determines properties that govern the efficiency of EC systems (e.g. precipitate reactivity and colloidal stability), it is essential to understand the individual and interdependent structural effects of common groundwater ions. In this work, we integrate Fe K-edge EXAFS spectroscopy with the Pair Distribution Function (PDF) technique to create a detailed description of EC precipitate structure as a function of electrolyte chemistry. EC precipitate samples were generated in a range of individual and combined concentrations of Ca, Mg, P, As(V), and Si, encompassing most of the typical levels found in natural groundwater. Combining complementary EXAFS and PDF techniques with batch uptake experiments and general chemical reasoning, we obtain structural representations of EC precipitates that are inaccessible with any single characterization technique. Our results indicate that the presence of As(V), P, and Si oxyanions promote the formation of nanoscale material bearing similar, but not identical, intermediate-ranged atomic pair correlations as 2-line ferrihydrite (2LFH), rather than lepidocrocite (Lp) which is generated in an NaCl electrolyte. However, when Ca or Mg is added to oxyanion electrolytes, Fe-Fe polymerization and particle size both tend to increase and a Lp-like material with characteristic Fe-O and Fe-Fe pair correlations is once again favored. The presence of either Ca or Mg also enhances the removal P, As(V), and to a lesser extent, Si per mass of Fe. The analysis from EXAFS and PDF spectra provide new insights into the polyhedral connectivity of nanoscale oxyanion-bearing HFO formed under a wide range of chemical conditions, improving predictions of EC performance in the field and allowing for knowledge-based improvements in the design of future EC systems. Our PDF data also show that the most disordered EC precipitate samples (formed at high oxyanion/Fe ratios) all share a similar "backbone" of 3-4 peaks beyond the first 4 Å, regardless of the oxyanion present during synthesis. Using 2LFH as a reference, we index all atomic pair correlations throughout the coherently scattering structure of our disordered samples.

  13. A new hybrid treatment system of bioreactors and electrocoagulation for superior removal of organic and nutrient pollutants from municipal wastewater.

    PubMed

    Nguyen, Dinh Duc; Ngo, Huu Hao; Yoon, Yong Soo

    2014-02-01

    This paper evaluated a novel pilot scale hybrid treatment system which combines rotating hanging media bioreactor (RHMBR), submerged membrane bioreactor (SMBR) along with electrocoagulation (EC) as post treatment to treat organic and nutrient pollutants from municipal wastewater. The results indicated that the highest removal efficiency was achieved at the internal recycling ratio as 400% of the influent flow rate which produced a superior effluent quality with 0.26mgBOD5L(-1), 11.46mgCODCrL(-1), 0.00mgNH4(+)-NL(-1), and 3.81mgT-NL(-1), 0.03mgT-PL(-1). During 16months of operation, NH4(+)-N was completely eliminated and T-P removal efficiency was also up to 100%. It was found that increasing in internal recycling ratio could improve the nitrate and nitrogen removal efficiencies. Moreover, the TSS and coliform bacteria concentration after treatment was less than 5mgL(-1) and 30MPNmL(-1), respectively, regardless of internal recycling ratios and its influent concentration. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Chemical or electrochemical techniques, followed by ion exchange, for recycle of textile dye wastewater.

    PubMed

    Raghu, S; Ahmed Basha, C

    2007-10-22

    This paper examines the use of chemical or electrocoagulation treatment process followed by ion-exchange process of the textile dye effluent. The dye effluent was treated using polymeric coagulant (cationic dye-fixing agent) or electrocoagulation (iron and aluminum electrode) process under various conditions such as various current densities and effect of pH. Efficiencies of COD reduction, colour removal and power consumption were studied for each process. The chemical or electrochemical treatment are indented primarily to remove colour and COD of wastewater while ion exchange is used to further improve the removal efficiency of the colour, COD, Fe concentration, conductivity, alkalinity and total dissolved solids (TDS). From the results chemical coagulation, maximum COD reduction of about 81.3% was obtained at 300 mg/l of coagulant whereas in electrocoagulation process, maximum COD removal of about 92.31% (0.25 A/dm2) was achieved with energy consumption of about 19.29 k Wh/kg of COD and 80% (1A/dm(2)) COD removal was obtained with energy consumption of about 130.095 k Wh/kg of COD at iron and aluminum electrodes, respectively. All the experimental results, throughout the present study, have indicated that chemical or electrocoagulation treatment followed by ion-exchange methods were very effective and were capable of elevating quality of the treated wastewater effluent to the reuse standard of the textile industry.

  15. Comparison between electrocoagulation and chemical precipitation for metals removal from acidic soil leachate.

    PubMed

    Meunier, Nathalie; Drogui, Patrick; Montané, Camille; Hausler, Robert; Mercier, Guy; Blais, Jean-François

    2006-09-01

    This paper provides a quantitative comparison between electrocoagulation and chemical precipitation based on heavy metals (Cd, Cr, Cu, Ni, Pb and Zn) removal from acidic soil leachate (ASL) at the laboratory pilot scale. Chemical precipitation was evaluated using either calcium hydroxide or sodium hydroxide, whereas electrocoagulation was evaluated via an electrolytic cell using mild steel electrodes. Chemical precipitation was as effective as electrocoagulation in removing metals from ASL having low contamination levels (30 mg Pbl(-1) and 18 mg Znl(-1)). For ASL enriched with different metals (each concentration of metals was initially adjusted to 100 mg l(-1)), the residual Cr, Cu, Pb and Zn concentrations at the end of the experiments were below the acceptable level recommended for discharge in sewage urban works (more than 99.8% of metal was removed) using either electrocoagulation or chemical precipitation. Cd was more effectively removed by electrochemical treatment, whereas Ni was easily removed by chemical treatment. The cost for energy, chemicals and disposal of metallic residue of electrocoagulation process ranged from USD 8.83 to 13.95 tds(-1), which was up to five times lower than that recorded using chemical precipitation. Highly effective electrocoagulation was observed as the ASL was specifically enriched with high concentration of Pb (250-2000 mg Pbl(-1)). More than 99.5% of Pb was removed regardless of the initial Pb concentration imposed in ASL and, in all cases, the residual Pb concentrations (0.0-1.44 mg l(-1)) were below the limiting value (2.0 mg l(-1)) for effluent discharge in sewage works.

  16. In-situ identification of iron electrocoagulation speciation and application for natural organic matter (NOM) removal.

    PubMed

    Dubrawski, Kristian L; Mohseni, Madjid

    2013-09-15

    In this work, iron speciation in electrocoagulation (EC) was studied to determine the impact of operating parameters on natural organic matter (NOM) removal from natural water. Two electrochemical EC parameters, current density (i) and charge loading rate (CLR), were investigated. Variation of these parameters led to a near unity current efficiency (φ = 0.957 ± 0.03), at any combination of i in a range of 1-25 mA/cm(2) and CLR in a range of 12-300 C/L/min. Higher i and CLR led to a higher bulk pH and limited the amount of dissolved oxygen (DO) reduced at the cathode surface due to mass transfer limitations. A low i (1 mA/cm(2)) and intermediate CLR (60 C/L/min) resulted in low bulk DO (<2.5 mg/L), where green rust (GR) was identified by in-situ Raman spectroscopy as the primary crystalline electrochemical product. Longer electrolysis times at higher i led to magnetite (Fe3O4) formation. Both higher (300 C/L/min) and lower (12 C/L/min) CLR values led to increased DO and/or increased pH, with lepidocrocite (γ-FeOOH) as the only crystalline species observed. The NOM removal of the three identified species was compared, with conditions leading to GR formation showing the greatest dissolved organic carbon removal, and highest removal of the low apparent molecular weight (<550 Da) chromophoric NOM fraction, determined by high performance size exclusion chromatography. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Treatment of emulsified oils by electrocoagulation: pulsed voltage applications.

    PubMed

    Genc, Ayten; Bakirci, Busra

    2015-01-01

    The effect of pulsed voltage application on energy consumption during electrocoagulation was investigated. Three voltage profiles having the same arithmetic average with respect to time were applied to the electrodes. The specific energy consumption for these profiles were evaluated and analyzed together with oil removal efficiencies. The effects of applied voltages, electrode materials, electrode configurations, and pH on oil removal efficiency were determined. Electrocoagulation experiments were performed by using synthetic and real wastewater samples. The pulsed voltages saved energy during the electrocoagulation process. In continuous operation, energy saving was as high as 48%. Aluminum electrodes used for the treatment of emulsified oils resulted in higher oil removal efficiencies in comparison with stainless steel and iron electrodes. When the electrodes gap was less than 1 cm, higher oil removal efficiencies were obtained. The highest oil removal efficiencies were 95% and 35% for the batch and continuous operating modes, respectively.

  18. Treatment of dairy effluents by electrocoagulation using aluminium electrodes.

    PubMed

    Tchamango, Serge; Nanseu-Njiki, Charles P; Ngameni, Emmanuel; Hadjiev, Dimiter; Darchen, André

    2010-01-15

    This work sets out to examine the efficiency of an electrolytic treatment: electrocoagulation, applied to dairy effluents. The experiments were carried out using a soluble aluminium anode on artificial wastewater derived from solutions of milk powder. The flocks generated during this treatment were separated by filtration. The analysis of the filtrates showed that the chemical oxygen demand (COD) was reduced by up to 61% while the removal of phosphorus, nitrogen contents, and turbidity were 89, 81 and 100%, respectively. An analogous treatment applied to phosphate and lactose solutions revealed that lactose was not eliminated, a fact that could account for the rather poor lowering of the COD. Compared to the chemical coagulation treatment with aluminium sulphate, the efficiency of the electrocoagulation technique was almost identical. However the wastewaters treated by electrocoagulation differed by the fact that they exhibited a lower conductivity and a neutral pH value (by contrast to the acid nature of the solution treated by the chemical coagulation). This result (low conductivity, neutral pH) tends to show that it may be possible to recycle the treated water for some industrial uses. Moreover, the electrocoagulation process uses fewer reagents: the mass of the aluminium anode dissolved during the treatment is lower compared to the quantity of the aluminium salt used in chemical coagulation. These two observations clearly show that the electrocoagulation technique is more performing. Copyright 2009 Elsevier B.V. All rights reserved.

  19. The influence of electrode type on electrocoagulation process for removal of chromium (VI) metal in plating industrial wastewater

    NASA Astrophysics Data System (ADS)

    Prasetyaningrum, Aji; Jos, Bakti; Dharmawan, Yudhy; Prabowo, Bilal T.; Fathurrazan, Muh.; Fyrouzabadi

    2018-05-01

    Chromium (VI) is one of the major metallic pollutants in plating industrial wastewater. Cr(VI) is one of toxic metal that cause serious threat to human health and the environment because its non-biodegradable. Among the technologies for removing these pollutants, electrocoagulation can be considered as an effective method. This method have some advantages such as less amount of produced sludge and high efficiency in removal of pollutants.This research intended to study the effects of type of electrode on the degree of Cr(VI) removal from wastewater of plating industry using electrocoagulation method. This laboratory research conducted with 3 types of electrode (aluminum, stainless and combination of both electrode). Synthetic chromium wastewater was prepared at the initial concentration of 100 mg L-1. The process was conducted at pH 3. The electricity current was setting at 3 Ampere. The variable of time of electrocoagulation at 1 and 2 hours. After performing the process on electrochemical cells, samples analyzed by the UV-Vis spectrophotometer regarding amount of Cr(VI) metals. The results showed that aluminium was the best performance electrode at variable of 2 hours with 26% of reduction of Cr(VI)metal content in plating industrial waste water.

  20. Treatment of an azo dye effluent by peroxi-coagulation and its comparison to traditional electrochemical advanced processes.

    PubMed

    do Vale-Júnior, Edilson; da Silva, Djalma R; Fajardo, Ana S; Martínez-Huitle, Carlos A

    2018-08-01

    Peroxi-coagulation (PC) is an interesting new process that has not been widely studied in the literature. This work presents the application of this technology to treat an azo dye synthetic effluent, studying the effect of different parameters including initial pH, current density (j), initial dye concentration and supporting electrolyte. The two former variables significantly affected the colour removal of the wastewater, followed by the initial dye concentration and the kind of electrolyte, in a lesser extent. The optimum operating conditions achieved were initial pH of 3.0, j = 33.3 mA cm -2 , 100 mg L -1 of methyl orange (MO) and Na 2 SO 4 as supporting electrolyte. The performance of PC was also compared to other electrochemical advanced processes, under similar experimental conditions. Results indicate that the kinetic decay of the MO increases in the following order: electrocoagulation (EC) < electrochemical oxidation (EO) with electrogenerated H 2 O 2 < PC < electro-Fenton (EF). This behaviour is given to the high oxidant character of the homogenous OH radicals generated by EF and PC approaches. The EO process with production of H 2 O 2 (EO-H 2 O 2 ) is limited by mass transport and the EC, as a separation method, takes longer times to achieve similar removal results. Energy requirements about 0.06 kWh g COD -1 , 0.09 kWh g COD -1 , 0.7 kWh g COD -1 and 0.1 kWh g COD -1 were achieved for PC, EF, EO-H 2 O 2 and EC, respectively. Degradation intermediates were monitored and carboxylic acids were detected for PC and EF processes, being rapidly removed by the former technology. PC emerges as a promising and competitive alternative for wastewaters depollution, among other oxidative approaches. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Treatment of real wastewater produced from Mobil car wash station using electrocoagulation technique.

    PubMed

    El-Ashtoukhy, E-S Z; Amin, N K; Fouad, Y O

    2015-10-01

    This paper deals with the electrocoagulation of real wastewater produced from a car wash station using a new cell design featuring a horizontal spiral anode placed above a horizontal disc cathode. The study dealt with the chemical oxygen demand (COD) reduction and turbidity removal using electrodes in a batch mode. Various operating parameters such as current density, initial pH, NaCl concentration, temperature, and electrode material were examined to optimize the performance of the process. Also, characterization of sludge formed during electrocoagulation was carried out. The results indicated that the COD reduction and turbidity removal increase with increasing the current density and NaCl concentration; pH from 7 to 8 was found to be optimum for treating the wastewater. Temperature was found to have an insignificant effect on the process. Aluminum was superior to iron as a sacrificial electrode material in treating car wash wastewater. Energy consumption based on COD reduction ranged from 2.32 to 15.1 kWh/kg COD removed depending on the operating conditions. Finally, the sludge produced during electrocoagulation using aluminum electrodes was characterized by scanning electron microscopy (SEM) and energy dispersive spectrometry (EDS) analysis.

  2. A sustainable biorefinery to convert agricultural residues into value-added chemicals.

    PubMed

    Liu, Zhiguo; Liao, Wei; Liu, Yan

    2016-01-01

    Animal wastes are of particular environmental concern due to greenhouse gases emissions, odor problem, and potential water contamination. Anaerobic digestion (AD) is an effective and widely used technology to treat them for bioenergy production. However, the sustainability of AD is compromised by two by-products of the nutrient-rich liquid digestate and the fiber-rich solid digestate. To overcome these limitations, this paper demonstrates a biorefinery concept to fully utilize animal wastes and create a new value-added route for animal waste management. The studied biorefinery includes an AD, electrocoagulation (EC) treatment of the liquid digestate, and fungal conversion of the solid fiber into a fine chemical-chitin. Animal wastes were first treated by an AD to produce methane gas for energy generation to power the entire biorefinery. The resulting liquid digestate was treated by EC to reclaim water. Enzymatic hydrolysis and fungal fermentation were then applied on the cellulose-rich solid digestate to produce chitin. EC water was used as the processing water for the fungal fermentation. The results indicate that the studied biorefinery converts 1 kg dry animal wastes into 17 g fungal biomass containing 12 % of chitin (10 % of glucosamine), and generates 1.7 MJ renewable energy and 8.5 kg irrigation water. This study demonstrates an energy positive and freshwater-free biorefinery to simultaneously treat animal wastes and produce a fine chemical-chitin. The sustainable biorefinery concept provides a win-win solution for agricultural waste management and value-added chemical production.

  3. Electrocoagulation treatment of raw landfill leachate using iron-based electrodes: Effects of process parameters and optimization.

    PubMed

    Huda, N; Raman, A A A; Bello, M M; Ramesh, S

    2017-12-15

    The main problem of landfill leachate is its diverse composition comprising many persistent organic pollutants which must be removed before being discharge into the environment. This study investigated the treatment of raw landfill leachate using electrocoagulation process. An electrocoagulation system was designed with iron as both the anode and cathode. The effects of inter-electrode distance, initial pH and electrolyte concentration on colour and COD removals were investigated. All these factors were found to have significant effects on the colour removal. On the other hand, electrolyte concentration was the most significant parameter affecting the COD removal. Numerical optimization was also conducted to obtain the optimum process performance. Under optimum conditions (initial pH: 7.73, inter-electrode distance: 1.16 cm, and electrolyte concentration (NaCl): 2.00 g/L), the process could remove up to 82.7% colour and 45.1% COD. The process can be applied as a pre-treatment for raw leachates before applying other appropriate treatment technologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Intravascular application of electrocautery in a rabbit model of abdominal aortic endarterectomy

    PubMed Central

    Wang, Chuan; Xin, Yi; Li, Na; Li, Diankun; Li, Jingxing; Gu, Chengxiong

    2017-01-01

    Effective therapies for preventing perioperative complications such as thrombosis and inflammation after coronary endarterectomy (CE) are lacking. Electrocoagulation electrotomes have been routinely used in surgery for their cutting, clotting, and hemostatic properties. As strong flattening tools, their electrocautery function may prevent mechanical intimal-adventitial injury to arterial circulation and attenuate stenosis. The present study investigated the effects of intravascular application of electrocautery on ameliorating inflammation and thrombosis in a rabbit model of abdominal aortic endarterectomy. New Zealand rabbits were randomly divided into the sham, control (endarterectomy), and study (endarterectomy + electrocautery) groups with 10 in each group. Abdominal aortas were partially blocked and intima was removed. Electrocautery was performed with an electrocoagulation electrotome through the entire blocked vessel lumen. Vascular ultrasound parameters, molecular biological and histological characteristics of the abdominal aorta including vascular diameter, blood flow velocity, serum interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) levels, and apoptosis rate of vascular endothelial cells (ECs) were evaluated postoperatively by vascular Doppler ultrasound, ELISA, real-time RT-PCR, flow cytometry, and immunofluorescence at various time points. Compared with the endarterectomy + electrocautery group, the isolated endarterectomy group had significantly increased levels and gene expression of TNF-α and IL-6 (P<0.05), and rates of apoptosis of vascular ECs (P<0.05), with gradual vascular stenosis and decreased blood flow velocity. In conclusion, intravascular application of electrocautery has favorable short-term effects on the abdominal aorta and can reduce inflammation in a rabbit model of abdominal aorta endarterectomy. Long-term anti-inflammatory and anti-thrombotic effects on arterial remodeling and the clinical value of electrocautery in CE remain to be determined. PMID:28672932

  5. Intravascular application of electrocautery in a rabbit model of abdominal aortic endarterectomy.

    PubMed

    Wang, Chuan; Xin, Yi; Li, Na; Li, Diankun; Li, Jingxing; Gu, Chengxiong

    2017-07-01

    Effective therapies for preventing perioperative complications such as thrombosis and inflammation after coronary endarterectomy (CE) are lacking. Electrocoagulation electrotomes have been routinely used in surgery for their cutting, clotting, and hemostatic properties. As strong flattening tools, their electrocautery function may prevent mechanical intimal-adventitial injury to arterial circulation and attenuate stenosis. The present study investigated the effects of intravascular application of electrocautery on ameliorating inflammation and thrombosis in a rabbit model of abdominal aortic endarterectomy. New Zealand rabbits were randomly divided into the sham, control (endarterectomy), and study (endarterectomy + electrocautery) groups with 10 in each group. Abdominal aortas were partially blocked and intima was removed. Electrocautery was performed with an electrocoagulation electrotome through the entire blocked vessel lumen. Vascular ultrasound parameters, molecular biological and histological characteristics of the abdominal aorta including vascular diameter, blood flow velocity, serum interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) levels, and apoptosis rate of vascular endothelial cells (ECs) were evaluated postoperatively by vascular Doppler ultrasound, ELISA, real-time RT-PCR, flow cytometry, and immunofluorescence at various time points. Compared with the endarterectomy + electrocautery group, the isolated endarterectomy group had significantly increased levels and gene expression of TNF-α and IL-6 (P<0.05), and rates of apoptosis of vascular ECs (P<0.05), with gradual vascular stenosis and decreased blood flow velocity. In conclusion, intravascular application of electrocautery has favorable short-term effects on the abdominal aorta and can reduce inflammation in a rabbit model of abdominal aorta endarterectomy. Long-term anti-inflammatory and anti-thrombotic effects on arterial remodeling and the clinical value of electrocautery in CE remain to be determined.

  6. Electrochemical removal of phenol from oil refinery wastewater.

    PubMed

    Abdelwahab, O; Amin, N K; El-Ashtoukhy, E-S Z

    2009-04-30

    This study explores the possibility of using electrocoagulation to remove phenol from oil refinery waste effluent using a cell with horizontally oriented aluminum cathode and a horizontal aluminum screen anode. The removal of phenol was investigated in terms of various parameters namely: pH, operating time, current density, initial phenol concentration and addition of NaCl. Removal of phenol during electrocoagulation was due to combined effect of sweep coagulation and adsorption. The results showed that, at high current density and solution pH 7, remarkable removal of 97% of phenol after 2h can be achieved. The rate of electrocoagulation was observed to increase as the phenol concentration decreases; the maximum removal rate was attained at 30 mg L(-1) phenol concentration. For a given current density using an array of closely packed Al screens as anode was found to be more effective than single screen anode, the percentage phenol removal was found to increase with increasing the number of screens per array. After 2h of electrocoagulation, 94.5% of initial phenol concentration was removed from the petroleum refinery wastewater. Energy consumption and aluminum Electrode consumption were calculated per gram of phenol removed. The present study shows that, electrocoagulation of phenol using aluminum electrodes is a promising process.

  7. Effect of electrolyte nature on kinetics of remazol yellow G removal by electrocoagulation

    NASA Astrophysics Data System (ADS)

    Rajabi, M.; Bagheri-Roochi, M.; Asghari, A.

    2011-10-01

    The present study describes an electrocoagulation process for the removal of remazol yellow G from dye solutions using Iron as the anode and Steel as the cathode. Pseudo-first-order, pseudo-second-order and intraparticle diffusion models were used to analyze the kinetic data obtained at different concentrations in different conditions. The adsorption kinetics was well described by the pseudo-second-order kinetic model.

  8. Sequential electrochemical treatment of dairy wastewater using aluminum and DSA-type anodes.

    PubMed

    Borbón, Brenda; Oropeza-Guzman, Mercedes Teresita; Brillas, Enric; Sirés, Ignasi

    2014-01-01

    Dairy wastewater is characterized by a high content of hardly biodegradable dissolved, colloidal, and suspended organic matter. This work firstly investigates the performance of two individual electrochemical treatments, namely electrocoagulation (EC) and electro-oxidation (EO), in order to finally assess the mineralization ability of a sequential EC/EO process. EC with an Al anode was employed as a primary pretreatment for the conditioning of 800 mL of wastewater. A complete reduction of turbidity, as well as 90 and 81% of chemical oxygen demand (COD) and total organic carbon (TOC) removal, respectively, were achieved after 120 min of EC at 9.09 mA cm(-2). For EO, two kinds of dimensionally stable anodes (DSA) electrodes (Ti/IrO₂-Ta₂O₅ and Ti/IrO₂-SnO₂-Sb₂O₅) were prepared by the Pechini method, obtaining homogeneous coatings with uniform composition and high roughness. The (·)OH formed at the DSA surface from H₂O oxidation were not detected by electron spin resonance. However, their indirect determination by means of H₂O₂ measurements revealed that Ti/IrO₂-SnO₂-Sb₂O₅ is able to produce partially physisorbed radicals. Since the characterization of the wastewater revealed the presence of indole derivatives, preliminary bulk electrolyses were done in ultrapure water containing 1 mM indole in sulfate and/or chloride media. The performance of EO with the Ti/IrO₂-Ta₂O₅ anode was evaluated from the TOC removal and the UV/Vis absorbance decay. The mineralization was very poor in 0.05 M Na₂SO₄, whereas it increased considerably at a greater Cl(-) content, meaning that the oxidation mediated by electrogenerated species such as Cl₂, HClO, and/or ClO(-) competes and even predominates over the (·)OH-mediated oxidation. The EO treatment of EC-pretreated dairy wastewater allowed obtaining a global 98 % TOC removal, decreasing from 1,062 to <30 mg L(-1).

  9. Electrocoagulation with polarity switch for fast oil removal from oil in water emulsions.

    PubMed

    Gobbi, Lorena C A; Nascimento, Izabela L; Muniz, Eduardo P; Rocha, Sandra M S; Porto, Paulo S S

    2018-05-01

    An electrocoagulation technique using a 3.5 L reactor, with aluminum electrodes in a monopolar arrangement with polarity switch at each 10 s was used to separate oil from synthetic oily water similar in oil concentration to produced water from offshore platforms. Up to 98% of oil removal was achieved after 20 min of processing. Processing time dependence of the oil removal and pH was measured and successfully adjusted to exponential models, indicating a pseudo first order behavior. Statistical analysis was used to prove that electrical conductivity and total solids depend significantly on the concentration of electrolyte (NaCl) in the medium. Oil removal depends mostly on the distance between the electrodes but is proportional to electrolyte concentration when initial pH is 8. Electrocoagulation with polarity switch maximizes the lifetime of the electrodes. The process reduced oil concentration to a value below that stipulated by law, proving it can be an efficient technology to minimize the offshore drilling impact in the environment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Application of Taguchi optimization on the cassava starch wastewater electrocoagulation using batch recycle method

    NASA Astrophysics Data System (ADS)

    Sudibyo, Hermida, L.; Suwardi

    2017-11-01

    Tapioca waste water is very difficult to treat; hence many tapioca factories could not treat it well. One of method which able to overcome this problem is electrodeposition. This process has high performance when it conducted using batch recycle process and use aluminum bipolar electrode. However, the optimum operation conditions are having a significant effect in the tapioca wastewater treatment using bath recycle process. In this research, The Taguchi method was successfully applied to know the optimum condition and the interaction between parameters in electrocoagulation process. The results show that current density, conductivity, electrode distance, and pH have a significant effect on the turbidity removal of cassava starch waste water.

  11. A parametric comparative study of electrocoagulation and coagulation using ultrafine quartz suspensions.

    PubMed

    Kiliç, Mehtap Gülsün; Hoşten, Cetin; Demirci, Sahinde

    2009-11-15

    This paper attempts to compare electrocoagulation using aluminum anodes and stainless steel cathodes with conventional coagulation by aluminum sulfate dosing on aqueous suspensions of ultrafine quartz. Several key parameters affecting the efficiency of electrocoagulation and coagulation were investigated with laboratory scale experiments in search of optimal parameter values. Optimal values of the parameters were determined on the basis of the efficiency of turbidity removal from ultrafine quartz suspensions. The parameters investigated in the study were suspension pH, electrical potential, current density, electrocoagulation time, and aluminum dosage. A comparison between electrocoagulation and coagulation was made on the basis of total dissolved aluminum, revealing that electrocoagulation and coagulation were equally effective at the same aluminum dosage for the removal of quartz particles from suspensions. Coagulation, however, was more effective in a wider pH range (pH 6-9) than electrocoagulation which yielded optimum effectiveness in a relatively narrower pH range around 9, where, in both methods, these pH values corresponded to near-zero zeta potentials of quartz particles. Furthermore, experimental results confirmed that electrocoagulation could display some pH buffering capacity. The kinetics of electrocoagulation was very fast (<10 min) in approaching a residual turbidity, which could be modeled with a second-order rate equation.

  12. EC treatment for reuse of tissue paper wastewater: aspects that affect energy consumption.

    PubMed

    Terrazas, Eduardo; Vázquez, Armando; Briones, Roberto; Lázaro, Isabel; Rodríguez, Israel

    2010-09-15

    The need for more rational use of water also calls for more efficient usage. An example is the production of tissue paper, where large amounts of water are discharged into the drain because its turbidity does not allow for recirculation. While this is a serious problem, even worse is the fact that the quality of such wastewater makes it difficult not only to recirculate but also to discharge due to environmental law restrictions. In this paper, electrocoagulation is proposed as a suitable technology to meet standards of water discharge, and even better, as a treatment option for removal of turbidity. Since energy consumption has been a drawback for EC applications, relevant aspects that contribute to increase it such as cell voltage and current density have been reviewed. For this purpose a systematic micro-electrolysis study combined with macro-electrolysis experiments have provided evidence that shows it is possible to achieve a turbidity removal of 92% with an energy consumption of 0.68 kWh/m(3). Thus, the results presented in this paper support the use of EC to obtain water of acceptable quality for reuse in the tissue paper industry. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Transformation characteristics of refractory pollutants in plugboard wastewater by an optimal electrocoagulation and electro-Fenton process.

    PubMed

    Zhao, Xu; Zhang, Baofeng; Liu, Huijuan; Chen, Fayuan; Li, Angzhen; Qu, Jiuhui

    2012-05-01

    The treatment of the plugboard wastewater was performed by an optimal electrocoagulation and electro-Fenton. The organic components with suspended fractions accounting for 30% COD were preferably removed via electrocoagulation at initial 5 min. In contrast, the removal efficiency was increased to 76% with the addition of H(2)O(2). The electrogenerated Fe(2+) reacts with H(2)O(2) and leads to the generation of (·)OH, which is responsible for the higher COD removal. However, overdosage H(2)O(2) will consume (·)OH generated in the electro-Fenton process and lead to the low COD removal. The COD removal efficiency decreased with the increased pH. The concentration of Fe(2+) ions was dependent on the solution pH, H(2)O(2) dosage and current density. The changes of organic characteristics in coagulation and oxidation process were differenced and evaluated using gel permeation chromatography, fluorescence excitation-emission scans and Fourier transform infrared spectroscopy. The fraction of the wastewater with aromatic structure and large molecular weight was decomposed into aliphatic structure and small molecular weight fraction in the electro-Fenton process. Copyright © 2012. Published by Elsevier Ltd.

  14. Effects of water chemistry on arsenic removal from drinking water by electrocoagulation.

    PubMed

    Wan, Wei; Pepping, Troy J; Banerji, Tuhin; Chaudhari, Sanjeev; Giammar, Daniel E

    2011-01-01

    Exposure to arsenic through drinking water poses a threat to human health. Electrocoagulation is a water treatment technology that involves electrolytic oxidation of anode materials and in-situ generation of coagulant. The electrochemical generation of coagulant is an alternative to using chemical coagulants, and the process can also oxidize As(III) to As(V). Batch electrocoagulation experiments were performed in the laboratory using iron electrodes. The experiments quantified the effects of pH, initial arsenic concentration and oxidation state, and concentrations of dissolved phosphate, silica and sulfate on the rate and extent of arsenic removal. The iron generated during electrocoagulation precipitated as lepidocrocite (γ-FeOOH), except when dissolved silica was present, and arsenic was removed by adsorption to the lepidocrocite. Arsenic removal was slower at higher pH. When solutions initially contained As(III), a portion of the As(III) was oxidized to As(V) during electrocoagulation. As(V) removal was faster than As(III) removal. The presence of 1 and 4 mg/L phosphate inhibited arsenic removal, while the presence of 5 and 20 mg/L silica or 10 and 50 mg/L sulfate had no significant effect on arsenic removal. For most conditions examined in this study, over 99.9% arsenic removal efficiency was achieved. Electrocoagulation was also highly effective at removing arsenic from drinking water in field trials conducted in a village in Eastern India. By using operation times long enough to produce sufficient iron oxide for removal of both phosphate and arsenate, the performance of the systems in field trials was not inhibited by high phosphate concentrations. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Influence of voltage input to heavy metal removal from electroplating wastewater using electrocoagulation process

    NASA Astrophysics Data System (ADS)

    Wulan, D. R.; Cahyaningsih, S.; Djaenudin

    2017-03-01

    In medium capacity, electroplating industry usually treats wastewater until 5 m3 per day. Heavy metal content becomes concern that should be reduced. Previous studies performed electrocoagulation method on laboratory scale, either batch or continuous. This study was aimed to compare the influence of voltage input variation into heavy metal removal in electroplating wastewater treatment using electrocoagulation process on laboratory-scale in order to determine the optimum condition for scaling up the reactor into pilot-scale. The laboratory study was performed in 1.5 L glass reactor in batch system using wastewater from electroplating industry, the voltage input varied at 20, 30 and 40 volt. The electrode consisted of aluminium 32 cm2 as sacrifice anode and copper 32 cm2 as cathode. During 120 min electrocoagulation process, the pH value was measured using pH meter, whereas the heavy metal of chromium, copper, iron, and zinc concentration were analysed using Atomic Absorption Spectrophotometer (AAS). Result showed that removal of heavy metals from wastewater increased due to the increasing of voltage input. Different initial concentration of heavy metals on wastewater, resulted the different detention time. At pilot-scale reactor with 30 V voltage input, chromium, iron, and zinc reached removal efficiency until 89-98%, when copper reached 79% efficiency. At 40V, removal efficiencies increased on same detention time, i.e. chromium, iron, and zinc reached 89-99%, whereas copper reached 85%. These removal efficiencies have complied the government standard except for copper that had higher initial concentration in wastewater. Kinetic rate also calculated in this study as the basic factor for scaling up the process.

  16. Electrocoagulation of wastewater from almond industry.

    PubMed

    Valero, David; Ortiz, Juan M; García, Vicente; Expósito, Eduardo; Montiel, Vicente; Aldaz, Antonio

    2011-08-01

    This work was carried out to study the treatment of almond industry wastewater by the electrocoagulation process. First of all, laboratory scale experiments were conducted in order to determine the effects of relevant wastewater characteristics such as conductivity and pH, as well as the process variables such as anode material, current density and operating time on the removal efficiencies of the total organic carbon (TOC) and the most representative analytical parameters. Next, the wastewater treatment process was scaled up to pre-industrial size using the best experimental conditions and parameters obtained at laboratory scale. Finally, economic parameters such as chemicals, energy consumption and sludge generation have been discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Boron removal by electrocoagulation and recovery.

    PubMed

    Isa, Mohamed Hasnain; Ezechi, Ezerie Henry; Ahmed, Zubair; Magram, Saleh Faraj; Kutty, Shamsul Rahman Mohamed

    2014-03-15

    This work investigated the removal of boron from wastewater and its recovery by electrocoagulation and hydrothermal mineralization methods respectively. The experimental design was developed using Box-Behnken Model. An initial study was performed based on four preselected variables (pH, current density, concentration and time) using synthetic wastewater. Response surface methodology (RSM) was used to evaluate the effect of process variables and their interaction on boron removal. The optimum conditions were obtained as pH 6.3, current density 17.4 mA/cm(2), and time 89 min. At these applied optimum conditions, 99.7% boron removal from an initial concentration of 10.4 mg/L was achieved. The process was effectively optimized by RSM with a desirability value of 1.0. The results showed that boron removal efficiency enhanced with increase in current density and treatment time. Removal efficiency also increased when pH was increased from 4 to 7 and subsequently decreased at pH 10. Adsorption kinetics study revealed that the reaction followed pseudo second order kinetic model; evidenced by high correlation and goodness of fit. Thermodynamics study showed that mechanism of boron adsorption was chemisorption and the reaction was endothermic in nature. Furthermore, the adsorption process was spontaneous as indicated by negative values of the adsorption free energy. Treatment of real produced water using electrocoagulation resulted in 98% boron removal. The hydrothermal mineralization study showed that borate minerals (Inyoite, Takadaite and Nifontovite) can be recovered as recyclable precipitate from electrocoagulation flocs of produced water. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Inflammatory cytokine expression following the use of bipolar electrocoagulation, ultracision harmonic scalpel and cold knife biopsy.

    PubMed

    Litta, Pietro; Saccardi, Carlo; Gizzo, Salvatore; Conte, Lorena; Ambrosi, Giulia; Sissi, Claudia; Palumbo, Manlio

    2015-08-01

    Electrical surgical devices may determine tissue damage through lateral thermal spread and activation of inflammatory processes. Several tissue effects are associated with the use of different surgical instruments. The aim of the present study was to compare tissue damage following the application of cold knife biopsy, bipolar electrocoagulation and the ultracision harmonic scalpel, through the analysis of inflammatory gene mediator expression. Three fragments of the round ligament (length 0.5 cm) were obtained from 22 females who had undergone total or subtotal laparoscopic hysterectomy using three different modes of resection: Cold knife biopsy, bipolar electrocoagulation and ultracision harmonic scalpel. The tissue fragments were examined by quantitative polymerase chain reaction (qPCR) analysis of selected cytokines. Gene expression analysis demonstrated large standard deviations due to individual variability among patients and indicated variability in the concentrations of cytokines in the three different samples. The quantity of cytokine mRNA in the cold knife biopsy samples was generally greater than those obtained by other techniques. Tumor necrosis factor-α expression was significantly higher in the sample obtained with the ultracision harmonic scalpel and bipolar electrocoagulation (P=0.033) when compared with cold knife biopsy. The inflammatory response was analyzed by the quantification of gene expression through the use of qPCR. The ultracision harmonic scalpel and bipolar electrocoagulation triggered the inflammatory cascade and resulted in an increased production of cytokines compared with cold knife biopsy.

  19. Extensive tissue damage of bovine ovaries after bipolar ovarian drilling compared to monopolar electrocoagulation or carbon dioxide laser.

    PubMed

    Hendriks, Marja-Liisa; van der Valk, Paul; Lambalk, Cornelis B; Broeckaert, Mark A M; Homburg, Roy; Hompes, Peter G A

    2010-02-01

    To evaluate the size of ovarian damage caused by ovarian drilling in polycystic ovary syndrome, the amount of inflicted damage was assessed for the most frequently used ovarian drilling techniques. Experimental prospective design. University clinic. Six fresh bovine ovaries per technique. Carbon dioxide (CO(2)) laser, monopolar electrocoagulation, and bipolar electrocoagulation were used for in vitro ovarian drilling. Amount of inflicted ovarian damage per procedure. Bipolar electrocoagulation resulted in significantly more destruction per burn than the CO(2) laser and monopolar electrocoagulation (287.6 versus 24.0 and 70.0 mm(3), respectively). The damage found per lesion was multiplied by the regularly applied number of punctures per procedure in daily practice (based on the literature). Again, the bipolar electrocoagulation resulted in significantly more tissue damage than the CO(2) laser and monopolar coagulation (2,876 versus 599 and 700 mm(3), respectively). Ovarian drilling, especially bipolar electrocoagulation, causes extensive destruction of the ovary. Given the same clinical effectiveness of the various procedures, it is essential to use the lowest possible dose that works; thus, the first choice should be CO(2) laser or monopolar electrocoagulation. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  20. The Removal of Perfluorinated Carboxylic Acids (PFCAs) on Zinc Anode by Electrocoagulation and the Effects of Chemical Flocculants

    NASA Astrophysics Data System (ADS)

    Xu, Lei; Wu, Jinhua

    2018-06-01

    This paper focus on the removal of PFCAs (C4-C10) in aquatic solution by electrocoagulation using Zn as anode. The effects of carbon chain length on the removal efficiencies of PFCAs were studied, in which the removal priorities of PFCA with different carbon chain length as well as the change of concentration during the electrocoagulation process were evaluated in the mixed solution of PFCAs (C4-C10). The addition of chemical flocculants was carried out to improve the electrocoagulation performances of PFCAs. The results shows that PFCAs with longer carbon chain length (C8-C10) have better removal efficiencies (almost 100%), and the longer one has the removal priorities in the mixed solution containing PFCAs (C4-C10). The addition of gelatin, APAM, and CPAM have different effects on the removal performances of PFCAs (C4-C7), in which C4 and C5 have no improve removal with any chemical flocculant due to their small molecular weight. APAM can improve the removal of C6 and C7 obviously, because of the larger floc generated by the electrostatic attraction between of APAM and Zn(OH)2 floc.

  1. Use of adsorption using granular activated carbon (GAC) for the enhancement of removal of chromium from synthetic wastewater by electrocoagulation.

    PubMed

    Vivek Narayanan, N; Ganesan, Mahesh

    2009-01-15

    The present work deals with removal of hexavalent chromium from synthetic effluents in a batch stirred electrocoagulation cell with iron-aluminium electrode pair coupled with adsorption using granular activated carbon (GAC). Several working parameters such as pH, current density, adsorbent concentration and operating time were studied in an attempt to achieve higher removal capacity. Results obtained with synthetic wastewater revealed that most effective removal capacities of chromium (VI) could be achieved when the initial pH was near 8. The removal of chromium (VI) during electrocoagulation, is due to the combined effect of chemical precipitation, coprecipitation, sweep coagulation and adsorption. In addition, increasing current density in a range of 6.7-26.7mA/cm2 and operating time from 20 to 100min enhanced the treatment rate to reduce metal ion concentration below admissible legal levels. The addition of GAC as adsorbent resulted in remarkable increase in the removal rate of chromium at lower current densities and operating time, than the conventional electrocoagulation process. The method was found to be highly efficient and relatively fast compared to existing conventional techniques.

  2. Zero Liquid Discharge approach in plating industry: treatment of degreasing effluents by electrocoagulation and anodic oxidation.

    PubMed

    Hermon, S; Grange, D; Pellet, Y; Lloret, G; Oyonarte, S; Bosch, F; Coste, M

    2008-01-01

    Degreasing waste effluents issued from a surface treatment plant were treated by electrochemical techniques in an attempt to reduce COD so that clean water can be returned to the rinse bath. Electrocoagulation, both with iron and aluminium anodes, and anodic oxidation with boron doped diamond (BDD) anodes were tested. In the electrocoagulation tests, the nature of the anodes did not impact significantly the reduction of COD. Electrocoagulation showed good COD removal rates, superior to 80%, but it was not able to reduce COD down to low levels. Anodic oxidation was able to reduce COD down to discharge limits; the oxidation efficiency was superior to 50%. Economical calculations show that anodic oxidation is best used as a polishing step after electrocoagulation. The bulk of the COD would be reduced by electrocoagulation and, then, anodic oxidation would reduce COD below discharge limits. The maximum treatable flow is somewhat hindered by the small sizes of current BDD installation but it would reach 600 m(3)/year if anodic oxidation is coupled with electrocoagulation, the operational cost being 2.90 Euros /m(3). (c) IWA Publishing 2008.

  3. Denitrification using a monopolar electrocoagulation/flotation (ECF) process.

    PubMed

    Emamjomeh, Mohammad M; Sivakumar, Muttucumaru

    2009-01-01

    Nitrate levels are limited due to health concerns in potable water. Nitrate is a common contaminant in water supplies, and especially prevalent in surface water supplies and shallow wells. Nitrate is a stable and highly soluble ion with low potential for precipitation or adsorption. These properties make it difficult to remove using conventional water treatment methods. A laboratory batch electrocoagulation/flotation (ECF) reactor was designed to investigate the effects of different parameters such as electrolysis time, electrolyte pH, initial nitrate concentration, and current rate on the nitrate removal efficiency. The optimum nitrate removal was observed at a pH range of between 9 and 11. It appeared that the nitrate removal rate was 93% when the initial nitrate concentration and electrolysis time respectively were 100 mg L(-1)-NO(3)(-) and 40 min. The results showed a linear relationship between the electrolysis time for total nitrate removal and the initial nitrate concentration. It is concluded that the electrocoagulation technology for denitrification can be an effective preliminary process when the ammonia byproduct must be effectively removed by the treatment facilities.

  4. Effect of iron ions and electric field on nitrification process in the periodic reversal bio-electrocoagulation system.

    PubMed

    Qian, Guangsheng; Hu, Xiaomin; Li, Liang; Ye, Linlin; Lv, Weijian

    2017-11-01

    This study explored the nitrification mechanism of a periodic reversal bio-electrocoagulation system with Fe-C electrodes. The ammonia nitrogen removal was compared in four identical cylindrical sequencing bath reactors. Two of them were reactors with Fe-C electrodes (S1) and C-C electrodes (S2), respectively. The other two were a reactor with iron ions (S3) and a traditional SBR (S4), respectively. The results demonstrated that the effect on enhancing nitrification in S1 was the best among all four SBRs, followed by S3, S2 and S4. Iron ions increased the biomass, and electric field improved the proton transfer and enzyme activity. The dominant bacterial genera in the four SBRs were Hyphomicrobium, Thauera, Nitrobacter, Nitrosomonas, Paracoccus and Hydrogenophaga. The iron ions may increase the levels of Nitrosomonas and Nitrobacter, both of which were the main microbes of the nitrification process. This study provided a significant and meaningful understanding of nitrification in a bio-electrocoagulation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Dual purpose recovered coagulant from drinking water treatment residuals for adjustment of initial pH and coagulation aid in electrocoagulation process.

    PubMed

    Jung, Kyung-Won; Ahn, Kyu-Hong

    2016-01-01

    The present study is focused on the application of recovered coagulant (RC) by acidification from drinking water treatment residuals for both adjusting the initial pH and aiding coagulant in electrocoagulation. To do this, real cotton textile wastewater was used as a target pollutant, and decolorization and chemical oxygen demand (COD) removal efficiency were monitored. A preliminary test indicated that a stainless steel electrode combined with RC significantly accelerated decolorization and COD removal efficiencies, by about 52% and 56%, respectively, even at an operating time of 5 min. A single electrocoagulation system meanwhile requires at least 40 min to attain the similar removal performances. Subsequently, the interactive effect of three independent variables (applied voltage, initial pH, and reaction time) on the response variables (decolorization and COD removal) was evaluated, and these parameters were statistically optimized using the response surface methodology. Analysis of variance showed a high coefficient of determination values (decolorization, R(2) = 0.9925 and COD removal, R(2) = 0.9973) and satisfactory prediction second-order polynomial quadratic regression models. Average decolorization and COD removal of 89.52% and 94.14%, respectively, were achieved, corresponding to 97.8% and 98.1% of the predicted values under statistically optimized conditions. The results suggest that the RC effectively played a dual role of both adjusting the initial pH and aiding coagulant in the electrocoagulation process.

  6. Dechlorophyllation by electrocoagulation.

    PubMed

    Jumpatong, Kanlaya; Phutdhawong, Weerachai; Buddhasukh, Duang

    2006-03-17

    Electrocoagulation was used for dechlorophyllation of alcoholic extracts from five plants. The results showed that for every plant extract studied, electrocoagulation was more efficient than the classical solvent extraction method in removing plant pigments, while not affecting the important secondary metabolites in those extracts.

  7. Pretreatment Capabilities and Benefits of Electrocoagulation

    DTIC Science & Technology

    2004-12-01

    PRETREATMENT CAPABILITIES AND BENEFITS OF ELECTROCOAGULATION Michael Mickley Mickley & Associates Boulder, Colorado...DATES COVERED - 4. TITLE AND SUBTITLE Pretreatment Capabilities and Benefits of Electrocoagulation 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...4 2.1 Background for Electrocoagulation Technology ………………………. 4 2.1.1 Applications ……………………………………………………. 4 2.1.2

  8. [Treatment by electrocoagulation in malignant tracheobronchial pathology].

    PubMed

    Frizzelli, R

    1986-01-01

    The author reports his experience of electrocoagulation used to remove tumoral obstruction of the trachea and primary bronchi. Endoscopic electrocoagulation using a fibrobronchoscope is a useful method. Its results and its cost are of interest, as confirmed by experience in 17 patients.

  9. Simultaneous arsenic and fluoride removal from synthetic and real groundwater by electrocoagulation process: Parametric and cost evaluation.

    PubMed

    Thakur, Lokendra Singh; Mondal, Prasenjit

    2017-04-01

    Co-existence of arsenic and fluoride in groundwater has raised severe health issues to living being. Thus, the present research has been conducted for simultaneous removal of arsenic and fluoride from synthetic groundwater by using electrocoagulation process with aluminum electrode. Effects of initial pH, current density, run time, inter electrode distance and NaCl concentration over percentage removal of arsenic and fluoride as well as operating cost have been studied. The optimum experimental conditions are found to be initial pH: 7, current density: 10 A/m 2 , run time: 95 min, inter electrode distance: 1 cm, NaCl concentration: 0.71 g/l for removal of 98.51% arsenic (initial concentration: 550 μg/l) and 88.33% fluoride (initial concentration: 12 mg/l). The concentration of arsenic and fluoride in treated water are found to be 8.19 μg/l and 1.4 mg/l, respectively, with an operating cost of 0.357 USD/m 3 treated water. Pseudo first and second order kinetic model of individual and simultaneous arsenic and fluoride removal in electrocoagulation have also been studied. Produced sludge characterization studies also confirm the presence of arsenic in As(III) form, and fluoride in sludge. The present electrocoagulation process is able to reduce the arsenic and fluoride concentration of synthetic as well as real groundwater to below 10 μg/l and 1.5 mg/l, respectively, which are maximum contaminant level of these elements in drinking water according to WHO guidelines. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Polishing of treated palm oil mill effluent (POME) from ponding system by electrocoagulation process.

    PubMed

    Bashir, Mohammed J K; Mau Han, Tham; Jun Wei, Lim; Choon Aun, Ng; Abu Amr, Salem S

    2016-01-01

    As the ponding system used to treat palm oil mill effluent (POME) frequently fails to satisfy the discharge standard in Malaysia, the present study aimed to resolve this problem using an optimized electrocoagulation process. Thus, a central composite design (CCD) module in response surface methodology was employed to optimize the interactions of process variables, namely current density, contact time and initial pH targeted on maximum removal of chemical oxygen demand (COD), colour and turbidity with satisfactory pH of discharge POME. The batch study was initially designed by CCD and statistical models of responses were subsequently derived to indicate the significant terms of interactive process variables. All models were verified by analysis of variance showing model significances with Prob > F < 0.01. The optimum performance was obtained at the current density of 56 mA/cm(2), contact time of 65 min and initial pH of 4.5, rendering complete removal of colour and turbidity with COD removal of 75.4%. The pH of post-treated POME of 7.6 was achieved, which is suitable for direct discharge. These predicted outputs were subsequently confirmed by insignificant standard deviation readings between predicted and actual values. This optimum condition also permitted the simultaneous removal of NH3-N, and various metal ions, signifying the superiority of the electrocoagulation process optimized by CCD.

  11. Degradation and biodegradability improvement of the olive mill wastewater by peroxi-electrocoagulation/electrooxidation-electroflotation process with bipolar aluminum electrodes.

    PubMed

    Esfandyari, Yahya; Mahdavi, Yousef; Seyedsalehi, Mahdi; Hoseini, Mohammad; Safari, Gholam Hossein; Ghozikali, Mohammad Ghanbari; Kamani, Hossein; Jaafari, Jalil

    2015-04-01

    Olive mill wastewater is considered as one of the most polluting effluents of the food industry and constitutes a source of important environmental problems. In this study, the removal of pollutants (chemical oxygen demand (COD), biochemical oxygen demand (BOD5), polyphenols, turbidity, color, total suspended solids (TSS), and oil and grease) from olive oil mill processing wastewater by peroxi-electrocoagulation/electrooxidation-electroflotation process with bipolar aluminum electrodes was evaluated using a pilot continuous reactor. In the electrochemical unit, aluminum (Al), stainless steel, and RuO2/Ti plates were used. The effects of pH, hydrogen peroxide doses, current density, NaCl concentrations, and reaction times were studied. Under optimal conditions of pH 4, current density of 40 mA/m(2), 1000 mg/L H2O2, 1 g/L NaCl, and 30-min reaction time, the peroxi-electrochemical method yielded very effective removal of organic pollution from the olive mill wastewater diluted four times. The treatment process reduced COD by 96%, BOD5 by 93.6%, total, polyphenols by 94.4%, color by 91.4%, turbidity by 88.7, suspended solids by 97% and oil and grease by 97.1%. The biodegradability index (BOD5/COD) increased from 0.29 to 0.46. Therefore, the peroxi-electrocoagulation/electrooxidation-electroflotation process is considered as an effective and feasible process for pre-treating olive mill wastewater, making possible a post-treatment of the effluent in a biological system.

  12. Clinical analysis of bronchoscopic electrocoagulation in pediatric patients

    PubMed Central

    Ni, Caiyun; Yu, Huafeng; Han, Xiaorong; Meng, Chen; Zhang, Yanqing

    2014-01-01

    This study is to explore the efficacy and safety of bronchoscopic electrocoagulation treatment for pediatric disease of poor ventilation. Seventy pediatric patients of airway stenosis and obstruction as well as pharyngeal and laryngeal cysts received bronchoscopic electrocoagulation treatment, including 15 cases of epiglottic cyst, 13 cases of cicatricial hyperplasia of fibrous tissue after trachea intubation, 5 cases of foreign body in bronchus and 37 cases of endobronchial tuberculosis. Before and after the last electrocoagulation treatment, treatment efficacy was evaluated by examining the patients’ clinical presentations and lesions in airway under bronchoscope, examining chest CT and pulmonary function, and estimating pulmonary atelectasis and ventilation function. Seventy cases of pediatric patients were treated by bronchoscopic electrocoagulation, with the total treatment number of 106 times. Among them, 66 cases were treated with marked efficacy and 4 cases were with effective treatment. There was no invalid treatment. The treatment efficacy was 100% without complications. Bronchoscopic electrocoagulation treatment is a fast, effective and safe therapeutic method in treating airway stenosis and obstruction, such as foreign body in bronchus, granulation tissue hyperplasia, and epiglottic cysts. It is worthy of being widely applied in clinic. PMID:25664086

  13. Removal of boron (B) from waste liquors.

    PubMed

    Jiang, J Q; Xu, Y; Simon, J; Quill, K; Shettle, K

    2006-01-01

    This paper explores the use of electrocoagulation to remove boron from waste effluent in comparison with alum coagulation. In treating model test wastes, greater boron removals were achieved with electrocoagulation at low doses than conventional alum coagulation when reaction was undertaken for the same conditions (pH 8.5, and initial boron concentration was 500 mg/L). Al electrocoagulation can achieve good boron removal performance (68.3%) at a dose of 2.1 (as molar ratio of Al:B, and for current density of 62.1 A/m2), while alum coagulation can only achieve the maximum boron removal of 56% at a dose of 2.4. Also, Al electrocoagulation can remove 15-20% more boron than alum coagulation for the same dose compared in the treatment of both model test wastes and industry effluent. The estimation of running costs shows that to achieve 75% boron removal from industry waste effluent, i.e. removing 150 g of boron from 1 m3 of effluent, electrocoagulation was 6.2 times cheaper than alum coagulation. The economic advantage of electrocoagulation in the treatment of boron-containing waste effluent is thus significant.

  14. Does bipolar electrocoagulation time affect vessel weld strength?

    PubMed Central

    Harrison, J D; Morris, D L

    1991-01-01

    The value of the bipolar electrocoagulator in the haemostasis of bleeding ulcers is controversial. We have therefore investigated the effect of different coagulation times on vessel weld strength achieved by the bipolar device. Welds were then made in vessels of known diameter using a standard 10F endoscopic haemostatic probe at coagulation times of two and 20 seconds. The intravascular temperature achieved at each time was measured. Vessel weld strength achieved by bipolar electrocoagulation was much greater at 20 seconds (approximately twice that at two seconds) and was highly significantly greater at all vessel diameters. There was a gradual reduction in weld strength with increasing vessel diameter, an effect that was seen for both two and 20 seconds of electrocoagulation. Intravascular temperature was significantly higher at 20 seconds than at two seconds. We conclude that vessel weld strength is related to coagulation time and that any future studies comparing the bipolar electrocoagulator with other haemostatic devices should use longer periods of bipolar electrocoagulation and record the coagulation time in order to optimise the clinical value of the device. PMID:1864540

  15. The extent of adhesion induction through electrocoagulation and suturing in an experimental rat study.

    PubMed

    Wallwiener, Christian W; Kraemer, Bernhard; Wallwiener, Markus; Brochhausen, Christoph; Isaacson, Keith B; Rajab, Taufiek K

    2010-03-01

    To investigate the effect of three types of peritoneal trauma occurring during surgery (high-frequency bipolar current, suturing, and mechanical damage) on postoperative adhesion formation in a rodent animal model. Randomized, controlled experimental trial in an in vitro animal model. Laboratory facilities of a university department of obstetrics and gynecology. Thirty-five female Wistar rats. Bilateral experimental lesions were created on the abdominal wall in every animal. The effect of minimal electrocoagulation was examined by creating lesions (n = 14) through sweeps of a bipolar forceps with a duration of 1 second and standardized pressure. For extensive electrocoagulation standardized lesions (n = 14) were created using sweeps of a duration of 3 seconds and three times more pressure. For mechanical trauma, standardized lesions (n = 14) were created by denuding the peritoneum mechanically. To study the additive effect of suturing, experimental lesions were created by suturing plus minimal electrocoagulation (n = 14) or mechanical denuding (n = 14). Adhesion incidence, quantity, and quality of the resulting adhesions were scored 14 days postoperatively. Adhesions were studied histopathologically. Mechanical denuding of the peritoneum did not result in adhesion formation. After minimal electrocoagulation, mean adhesion quantity of the traumatized area averaged 0%. This contrasted with extensive electrocoagulation, where there was 50% adhesion. Additional suturing increased mean adhesion quantity to 73% and 64% for superficial electrocoagulation and mechanical denuding, respectively. We conclude that superficial trauma limited mostly to the parietal peritoneum may be a negligible factor in adhesion formation in this model. This appears to be irrespective of the mode of trauma. However, additional trauma to the underlying tissues, either by deeper electrocoagulation or suturing, leads to significantly increased adhesion formation. These data also show that there is a spectrum of electrocoagulation trauma at the lower end of which there is little adhesion formation. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  16. A low sludge generated anode by hybrid solar electrocoagulation for the removal of lead

    NASA Astrophysics Data System (ADS)

    Hussin, F.; Aroua, M. K.

    2017-06-01

    In this work, perforated zinc is proposed as a new anode for lead removal by hybrid solar electrocoagulation. The characteristics of the sludge were investigated to understand the behaviour of lead removal during electrocoagulation. Sludge products formed were characterised using X-ray diffraction (XRD), X-ray fluorescence (XRF) and Field Emission Scanning Electron Microscopy (FESEM). In addition, the pH variation during electrocoagulation and effects on the sludge products were examined. At optimum conditions showed that the perforated zinc electrode produced better performance with high removal efficiency, low sludge volume index and less energy consumption.

  17. Treatment of phthalic acid esters by electrocoagulation with stainless steel electrodes using dimethyl phthalate as a model compound.

    PubMed

    Kabdaşli, Işik; Keleş, Asuman; Olmez-Hanci, Tuğba; Tünay, Olcay; Arslan-Alaton, Idil

    2009-11-15

    In this study, treatment of phthalates by electrocoagulation employing stainless steel electrodes was investigated using dimethyl phthalate (DMP) as a model compound. DMP was completely destructed within 30 min up to the high initial concentration of 100mg/L while total mineralization was also obtained within a couple of hours. The applied current density of 22.5 mA/cm(2) and electrolyte (NaCl) concentrations varying between 1000 and 1500 mg/L as chloride resulted in the highest treatment performance. The initial solution pH (2-6) had practically no effect on the process efficiency. Desorption experiments and the reaction rates obtained for DMP, COD and TOC abatements appeared to be a strong evidence of an oxidative removal mechanism. DMP removal fitted first order kinetics. COD and TOC removals began after the total DMP removal and also fitted first order kinetics. Activated sludge inhibition experiments revealed that toxicity could be significantly reduced by electrocoagulation application.

  18. Treatment of oily wastewater of a gas refinery by electrocoagulation using aluminum electrodes.

    PubMed

    Saeedi, Mohesn; Khalvati-Fahlyani, Amin

    2011-03-01

    Oily wastewaters are the most important discharges of gas refineries from an environmental point-of-view. In the present study, treatment of gas refinery oily wastewater by electrocoagulation using aluminum electrodes was investigated. The effects of electrode distance, initial pH, sodium sulfate (Na2SO4) as a supporting electrolyte, polyaluminum chloride dosage as a coagulant aid, and current density on the efficiency of chemical oxygen demand (COD) removal were examined. The results revealed that the COD removal rate increases by applying more current density and polyaluminum chloride and, to a lesser extent, Na2SO4 dosage. The results also showed that 97% COD can be removed at optimum operational conditions. Specific electrical energy consumption could be reduced from 19.48 kWh (kg COD removal)(-1) to 11.057 kWh (kg COD removal)(-1) using Na2SO4 as a supporting electrolyte. Gas chromatographic analysis of raw and treated wastewater also revealed that most normal hydrocarbons (nearly 99%) were removed during the electrocoagulation process.

  19. Removal of arsenate from groundwater by electrocoagulation method.

    PubMed

    Ali, Imran; Khan, Tabrez A; Asim, Mohd

    2012-06-01

    Arsenic, a toxic metalloid in drinking water, has become a major threat for human beings and other organisms. In the present work, attempts have been made to remove arsenate from the synthetic as well as natural water of Ballia district, India by electrocoagulation method. Efforts have also been made to optimize the various parameters such as initial arsenate concentration, pH, applied voltage, processing time, and working temperature. Electrocoagulation is a fast, inexpensive, selective, accurate, reproducible, and eco-friendly method for arsenate removal from groundwater. The present paper describes an electrocoagulation method for arsenate removal from groundwater using iron and zinc as anode and cathode, respectively. The maximum removal of arsenate was 98.8% at 2.0 mg L(-1), 7.0, 3.0 V, 10.0 min, and 30°C as arsenate concentration, pH, applied voltage, processing time, and working temperature, respectively. Relative standard deviation, coefficient of determination (r (2)), and confidence limits were varied from 1.50% to 1.59%, 0.9996% to 0.9998%, and 96.0% to 99.0%, respectively. The treated water was clear, colorless, and odorless without any secondary contamination. The developed and validated method was applied for arsenate removal of two samples of groundwater of Ballia district, U.P., India, having 0.563 to 0.805 mg L(-1), arsenate concentrations. The reported method is capable for the removal of arsenate completely (100% removal) from groundwater of Ballia district. There was no change in the groundwater quality after the removal of arsenate. The treated water was safe for drinking, bathing, and recreation purposes. Therefore, this method may be the choice of arsenate removal from natural groundwater.

  20. Removal of pollutants with determination of power consumption from landfill leachate wastewater using an electrocoagulation process: optimization using response surface methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Asaithambi, Perumal; Beyene, Dejene; Aziz, Abdul Raman Abdul; Alemayehu, Esayas

    2018-05-01

    Treatment of landfill leachate wastewater by electrocoagulation process using an aluminium electrode was investigated in a batch electrochemical cell reactor. Response surface methodology based on central composite design was used to optimize the operating parameters for the removal of % color and % total organic carbon (TOC) together with power consumption from landfill leachate. Effects of three important independent parameters such as current density ( X 1), inter-electrode distance ( X 2) and solution pH ( X 3) of the landfill leachate sample on the % color and % TOC removal with power consumption were investigated. A quadratic model was used to predict the % color and % TOC removal with power consumption in different experimental conditions. The significance of each independent variable was calculated by analysis of variance. In order to achieve the maximum % color and % TOC removal with minimum of power consumption, the optimum conditions were about current density ( X 1)—5.25 A/dm2, inter-electrode distance ( X 2)—1 cm and initial solution of effluent pH ( X 3)—7.83, with the yield of color removal of 74.57%, and TOC removal of 51.75% with the power consumption of 14.80 kWh/m3. Electrocoagulation process could be applied to remove pollutants from industrial effluents and wastewater.

  1. The treatment of chromium containing wastewater using electrocoagulation and the production of ceramic pigments from the resulting sludge.

    PubMed

    Tezcan Un, Umran; Onpeker, Suzan Eroglu; Ozel, Emel

    2017-09-15

    This research experimentally investigates the treatment of authentic electroplating wastewater with high Cr(VI) content by electrocoagulation with the obtained sludge being reused as a raw material to produce inorganic pigments. A zero waste process is introduced to help conserve resources and to minimize environmental effects. The effects of operational parameters on electrocoagulation are determined in a batch stirred reactor using an iron electrode. The best performance was observed when a current density 20 mA/cm 2 , pH 2.4 and 0.05 M NaCl electrolyte were maintained. The initial Cr(VI) concentration of 1000 mg/L was almost completely abated (∼100%) at an energy cost of 2.68 kWh/m 3 , fulfilling the EPA guideline of 2.77 mg/L within a single step process. The sludge was characterized using XRD and XRF showing that the sludge is a rich source of iron and chromium and can be reused to produce value added ceramic pigments. Pigments prepared in this way appeared to be reddish brown and black color in transparent glaze and were also characterized using XRD and XRF. In this study, a zero waste process is successfully introduced with ∼100% Cr(VI) removal, with subsequent reuse of the resulting sludge. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Remediation of phosphate-contaminated water by electrocoagulation with aluminium, aluminium alloy and mild steel anodes.

    PubMed

    Vasudevan, Subramanyan; Lakshmi, Jothinathan; Jayaraj, Jeganathan; Sozhan, Ganapathy

    2009-05-30

    The present study provides an electrocoagulation process for the remediation of phosphate-contaminated water using aluminium, aluminium alloy and mild steel as the anodes and stainless steel as the cathode. The various parameters like effect of anode materials, effect of pH, concentration of phosphate, current density, temperature and co-existing ions, and so forth, and the adsorption capacity was evaluated using both Freundlich and Langmuir isotherm models. The adsorption of phosphate preferably fitting the Langmuir adsorption isotherm suggests monolayer coverage of adsorbed molecules. The results showed that the maximum removal efficiency of 99% was achieved with aluminium alloy anode at a current density of 0.2 A dm(-2), at a pH of 7.0. The adsorption process follows second-order kinetics.

  3. [Establishment of mouse endometrial injury model by electrocoagulation].

    PubMed

    Hu, Xiaoxiao; Lin, Xiaona; Jiang, Yinshen; Shi, Libing; Wang, Jieyu; Zhao, Lijuan; Zhang, Songying

    2014-12-23

    To establish the murine model of moderate endometrial injury. Electrocoagulation was applied to induce endometrial injury of ICR mice with 0.5 watts power while contralateral uterine cavity acted as control without electrocoagulation. The endometrial histomorphology was observed in 7 days later by microscopy and fetal number of each lateral uterus assessed at 17.5 days after pregnancy. At 7 days post-electrocoagulation, the average endometrial thickness of operating side was significantly thinner than that of control side (1.14 ± 0.08 vs 1.88 ± 0.15 mm, P < 0.05). The density of endometrial glands of operating side was significantly lower than that of control side (20 ± 2 vs 32 ± 3 per 100x field, P < 0.05). After pregnancy, the average number of embryos at operating side decreased by 63.1% compared with control (3 ± 2 vs 8 ± 2, P < 0.01). The established model of endometrial electrocoagulation injury shows morphologic changes and decreased fertile ability. It has potential uses for animal studies of endometrial injury treatment.

  4. Translations on Environmental Quality, Number 127

    DTIC Science & Technology

    1976-12-29

    first cleansing is done "by the highly effective method of electrocoagulation . It is "based on the passage of a constant electric flow with a voltage of...chemical rea- gents and becomes suitable for repeated use in industry. With the aid of iod- exchange devices electrocoagulation is supplemented with... electrocoagulation method, it is creating unified devices for the various substances contained in water and is improving plant design. All this will guarantee

  5. Research on the enhancement of biological nitrogen removal at low temperatures from ammonium-rich wastewater by the bio-electrocoagulation technology in lab-scale systems, pilot-scale systems and a full-scale industrial wastewater treatment plant.

    PubMed

    Li, Liang; Qian, Guangsheng; Ye, Linlin; Hu, Xiaomin; Yu, Xin; Lyu, Weijian

    2018-09-01

    In cold areas, nitrogen removal performance of wastewater treatment plants (WWTP) declines greatly in winter. This paper systematically describes the enhancement effect of a periodic reverse electrocoagulation technology on biological nitrogen removal at low temperatures. The study showed that in the lab-scale systems, the electrocoagulation technology improved the biomass amount, enzyme activity and the amount of nitrogen removal bacteria (Nitrosomonas, Nitrobacter, Paracoccus, Thauera and Enterobacter). This enhanced nitrification and denitrification of activated sludge at low temperatures. In the pilot-scale systems, the electrocoagulation technology increased the relative abundance of cold-adapted microorganisms (Luteimonas and Trueperaceae) at low temperatures. In a full-scale industrial WWTP, comparison of data from winter 2015 and winter 2016 showed that effluent chemical oxygen demand (COD), NH 4 + -N, and NO 3 - -N reduced by 10.37, 3.84, and 136.43 t, respectively, throughout the winter, after installation of electrocoagulation devices. These results suggest that the electrocoagulation technology is able to improve the performance of activated sludge under low-temperature conditions. This technology provides a new way for upgrading of the performance of WWTPs in cold areas. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Electrocoagulation using a rotated anode: A novel reactor design for textile wastewater treatment.

    PubMed

    Naje, Ahmed Samir; Chelliapan, Shreeshivadasan; Zakaria, Zuriati; Abbas, Saad A

    2016-07-01

    This paper investigates the optimum operational conditions of a novel rotated bed electrocoagulation (EC) reactor for the treatment of textile wastewater. The effect of various operational parameters such as rotational speed, current density (CD), operational time (RT), pH, temperature, and inter-electrode distance (IED) on the pollutant removal efficiency were examined. In addition, the consumption of aluminum (Al) and electrical energy, as well as operating costs at optimum conditions were also calculated. The results indicated that the optimum conditions for the treatment of textile wastewater were achieved at CD = 4 mA/cm(2), RT = 10 min, rotational speed = 150 rpm, pH = 4.57, temperature = 25 °C, and IED = 1 cm. The electrode consumption, energy consumption, and operating costs were 0.038 kg/m(3), 4.66 kWh/m(3) and 0.44 US$/m(3), respectively. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solid (TSS), turbidity and color were 97.10%, 95.55%, 98%, 96% and 98.50%, respectively, at the first 10 min of reaction time, while the phenol compound of the wastewater was almost entirely removed (99.99%). The experimental results confirm that the new reactor design with rotated anode impellers and cathode rings provided high treatment efficiency at a reduced reaction time and with lower energy consumption. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Electrocoagulation of simulated reactive dyebath effluent with aluminum and stainless steel electrodes.

    PubMed

    Arslan-Alaton, Idil; Kabdaşli, Işik; Vardar, Burcu; Tünay, Olcay

    2009-05-30

    Reactive dyebath effluents are ideal candidates for electrocoagulation due to their intensive color, medium strength, recalcitrant COD and high electrolyte (NaCl) content. The present study focused on the treatability of simulated reactive dyebath effluent (COD(o)=300 mg/L; color in terms of absorbance values A(o,436)=0.532 cm(-1), A(o,525)=0.693 cm(-1) and A(o,620)=0.808 cm(-1)) employing electrocoagulation with aluminum and stainless steel electrodes. Optimization of critical operating parameters such as initial pH (pH(o) 3-11), applied current density (J(c)=22-87 mA/cm(2)) and electrolyte type (NaCl or Na(2)SO(4)) improved the overall treatment efficiencies resulting in effective decolorization (99% using stainless steel electrodes after 60 min, 95% using aluminum electrodes after 90 min electrocoagulation) and COD abatement (93% with stainless steel electrodes after 60 min, 86% with aluminum electrodes after 90 min of reaction time). Optimum electrocoagulation conditions were established as pH(o) 5 and J(c)=22 mA/cm(2) for both electrode materials. The COD and color removal efficiencies also depended on the electrolyte type. No in situ, surplus adsorbable organically bound halogens (AOX) formation associated with the use of NaCl as the electrolyte during electrocoagulation was detected. An economical evaluation was also carried out within the frame of the study. It was demonstrated that electrocoagulation of reactive dyebath effluent with aluminum and stainless steel electrodes was a considerably less electrical energy-intensive, alternative treatment method as compared with advanced chemical oxidation techniques.

  8. Electrocoagulation for the treatment of textile industry effluent--a review.

    PubMed

    Khandegar, V; Saroha, Anil K

    2013-10-15

    Various techniques such as physical, chemical, biological, advanced oxidation and electrochemical are used for the treatment of industrial effluent. The commonly used conventional biological treatment processes are time consuming, need large operational area and are not effective for effluent containing toxic elements. Advanced oxidation techniques result in high treatment cost and are generally used to obtain high purity grade water. The chemical coagulation technique is slow and generates large amount of sludge. Electrocoagulation has recently attracted attention as a potential technique for treating industrial effluent due to its versatility and environmental compatibility. This technique uses direct current source between metal electrodes immersed in the effluent, which causes the dissolution of electrode plates into the effluent. The metal ions, at an appropriate pH, can form wide range of coagulated species and metal hydroxides that destabilize and aggregate particles or precipitate and adsorb the dissolved contaminants. Therefore, the objective of the present manuscript is to review the potential of electrocoagulation for the treatment of industrial effluents, mainly removal of dyes from textile effluent. © 2013 Elsevier Ltd. All rights reserved.

  9. [Osteoid osteoma in children: 5 cases treated with electrocoagulation].

    PubMed

    Gilliaux, O; de Wispelaere, J-F; Charlier, H; Bodart, E

    2012-11-01

    Osteoid osteoma is a benign bone tumor. Its diagnosis is often delayed despite typical symptoms: severe pain mainly situated on the lower limbs and characteristically worse at night. Once diagnosed, an antalgic treatment by aspirin is well known to be very effective in relieving pain. Osteoid osteoma will resolve spontaneously. If symptoms persist despite the use of aspirin, surgery can be performed to remove the tumor. Percutaneous electrocoagulation can be performed instead of surgical resection as a less invasive procedure. The success rate of surgery and percutaneous electrocoagulation is comparable. We reviewed the cases of 5 patients who were hospitalized in our institution for percutaneous electrocoagulation of an osteoid osteoma. We compared them to the literature. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  10. A combined electrocoagulation-sorption process applied to mixed industrial wastewater.

    PubMed

    Linares-Hernández, Ivonne; Barrera-Díaz, Carlos; Roa-Morales, Gabriela; Bilyeu, Bryan; Ureña-Núñez, Fernando

    2007-06-01

    The removal of organic pollutants from a highly complex industrial wastewater by a aluminium electrocoagulation process coupled with biosorption was evaluated. Under optimal conditions of pH 8 and 45.45 Am(-2) current density, the electrochemical method yields a very effective reduction of all organic pollutants, this reduction was enhanced when the biosorption treatment was applied as a polishing step. Treatment reduced chemical oxygen demand (COD) by 84%, biochemical oxygen demand (BOD(5)) by 78%, color by 97%, turbidity by 98% and fecal coliforms by 99%. The chemical species formed in aqueous solution were determined. The initial and final pollutant levels in the wastewater were monitored using UV-vis spectrometry and cyclic voltammetry. Finally, the morphology and elemental composition of the biosorbent was characterized with scanning electron microscopy (SEM) and energy dispersion spectra (EDS).

  11. Treatment of sugar processing industry effluent up to remittance limits: Suitability of hybrid electrode for electrochemical reactor.

    PubMed

    Sahu, Omprakash

    2017-01-01

    Sugar industry is an oldest accommodates industry in the world. It required and discharges a large amount of water for processing. Removal of chemical oxygen demand and color through the electrochemical process including hybrid iron and aluminum electrode was examined for the treatment of cane-based sugar industry wastewater. Most favorable condition at pH 6.5, inter-electrode gap 20 mm, current density 156 A m -2 , electrolyte concentration 0.5 M and reaction time 120 min, 90% COD and 93.5% color removal was achieved. The sludge generated after treatment has less organic contain, which can be used as manure in agricultural crops. Overall the electrocoagulation was found to be reliable, efficient and economically fit to treat the sugar industry wastewater. •Electrocoagulation method for sugar processing industry wastewater treatment Optimization of operating parameters for maximum efficiency.•Physicochemical analysis of sludge and scum.•Significance of hydride metal electrode for pollutant removal.

  12. Winograd Method Versus Winograd Method With Electrocoagulation in the Treatment of Ingrown Toenails.

    PubMed

    Acar, Erdinc

    An important component of the Winograd surgical method for an ingrown toenail is total excision of the associated germinal matrix. However, this might not always be accomplished with the procedure. We hypothesized that the surgical results might be improved by adding electrocoagulation of the germinal matrix to the Winograd method. The objective of the present study was to compare the recurrence, satisfaction, and complication rates of the Winograd method with those of the Winograd method with electrocoagulation. We retrospectively evaluated the records of 102 patients with single Heifetz stage 2 or 3 ingrown toenails who had undergone surgery from January 2013 to October 2014 using 1 of these 2 methods. Of the 102 patients, 50 (49%) underwent the Winograd method and 52 (51%) underwent the Winograd method with electrocoagulation. The mean follow-up period of our patients was 12 (range 6 to 22) months. An ingrown toenail recurred in 3 patients (6%) in the Winograd group and in no patient in the Winograd with electrocoagulation group (p = .04). Among the patients in the Winograd group, 46 (92.0%) were satisfied or very satisfied. Among the patients in the Winograd plus electrocoagulation group, 49 (94.2%) were satisfied or very satisfied (p = .04). No complications developed in either group. In conclusion, the Winograd method for ingrown toenails results in high satisfaction rates, low recurrence rates, and low complication rates. The addition of electrocoagulation of the germinal matrix to the Winograd method could result in even lower recurrence rates, while maintaining high patient satisfaction and without increasing the risk of complications. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Role of the Functional State of the Hypothalamus in Bioelectric Reactions of the Cerebral Cortex to Radiation,

    DTIC Science & Technology

    The effect of subjection of the hypothalamus to electrocoagulation in the area of the mamillary bodies on the bioelectric activity and reactivity of...the cerebral cortex exposed to radiation was studied. Rabbits were irradiated on the 10th day after electrocoagulation . Immediately after... electrocoagulation , a decline in the excitability and functional activity of cortical neurons in the posterior section of the cortex and a decrease in the

  14. Comparison of the effects of laparoscopic bipolar electrocoagulation and intracorporeal suture application to ovarian reserve in benign ovarian cysts.

    PubMed

    Özgönen, Hakan; Erdemoglu, Evrim; Günyeli, Ilker; Güney, Mehmet; Mungan, Tamer

    2013-04-01

    Aim of the present study is to determine the effects of bipolar electrocoagulation and intracorporeal suture on the ovarian reserve after ovarian cystectomy. Sixty patients aged 18-42 years old and with a persistent adnexal mass were recruited to the study. Patients were randomized into suture hemostasis group or bipolar hemostasis group. Laparoscopic ovarian cystectomy was performed to all patients. Hemostasis was obtained by bipolar coagulation in 30 patients and by intracorporeal sutures in 30 patients. Serum levels of FSH, LH, estradiol, inhibin B and ultrasonographic measurements (antral follicle count and ovarian volume) were analyzed and recorded at day 3 of menstrual cycle, 1 and 3 months after the surgery. Basal FSH level measurement at the postoperative third month was significantly increased to 6.96 ± 1.86 mIU/ml (p < 0.05) in the bipolar electrocoagulation group. However, the decreased ovarian volume and antral follicle count was restored at the postoperative third month in the bipolar electrocoagulation group. Preoperative and postoperative FSH, LH, estradiol and inhibin B levels and ultrasonographic measurements were similar in the intracorporeal suture group. The unwanted effect of bipolar electrocoagulation on ovarian reserve is probably transient and causes minimal damage to ovary. FSH levels may be slightly elevated. Gentle use of bipolar electrocoagulation or intracorporeal are not found to effect ovarian reserve.

  15. Performance and microbial community analysis of bio-electrocoagulation on simultaneous nitrification and denitrification in submerged membrane bioreactor at limited dissolved oxygen.

    PubMed

    Li, Liang; Dong, Yihua; Qian, Guangsheng; Hu, Xiaomin; Ye, Linlin

    2018-06-01

    A pair of Fe-C electrodes was installed in a traditional submerged membrane bioreactor (MBR, Rc), and a novel asynchronous periodic reversal bio-electrocoagulation system (Re) was developed. The simultaneous nitrification and denitrification (SND) performance was discussed under limited dissolved oxygen (DO). Results showed that electrocoagulation enhanced total nitrogen (TN) removal from 59.48% to 75.09% at 1.2 mg/L DO. Additionally, Fe electrode could increase sludge concentration, particle size, and enzyme activities related to nitrogen removal. The enzyme activities of Hydroxylamine oxidoreductase (HAO), Nitrate Reductase (NAR), nitric oxide reductase NOR and nitrous oxide reductase (N 2 OR) in Re were 38.35%, 21.59%, 89.96% and 38.64% higher than Rc, respectively. Moreover, electrocoagulation was advantageous for nitrite accumulation, indicating partial nitrification and denitrification were more easily achieved in Re. Besides, results from high throughput sequencing analysis revealed that electrocoagulation increased the relative abundance of most genera related to nitrogen removal, including Nitrosomonas, Comamonadaceae_unclassified, Haliangium and Denitratisoma. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Treatment of acral persistent papular mucinosis with electrocoagulation.

    PubMed

    André Jorge, Flávia; Mimura Cortez, Tatiana; Guadalini Mendes, Fabiana; Esther Alencar Marques, Mariângela; Amante Miot, Hélio

    2011-01-01

    Acral persistent papular mucinosis is a rare localized form of lichen myxedematosus with few case reports and no documented therapeutic options. To report full resolution of acral persistent papular mucinosis after electrocoagulation. Case report of a 51-year-old white female diagnosed with an acral persistent papular mucinosis. The clinical and histopathologic features, treatment provided, and response to treatment are detailed. Acral persistent papular mucinosis presented as multiple asymptomatic normochromic papules on the wrists. Treatment with topical and intralesional steroids was unsatisfactory. Gentle electrocoagulation led to complete resolution of the lesions and negligible scarring. The favorable results remained for 6 months of follow-up, and no new lesions have emerged. Our case of acral persistent papular mucinosis was successfully treated with electrocoagulation and long-lasting, excellent cosmetic results.

  17. Treatment of automotive industry oily wastewater by electrocoagulation: statistical optimization of the operational parameters.

    PubMed

    GilPavas, Edison; Molina-Tirado, Kevin; Gómez-García, Miguel Angel

    2009-01-01

    An electrocoagulation process was used for the treatment of oily wastewater generated from an automotive industry in Medellín (Colombia). An electrochemical cell consisting of four parallel electrodes (Fe and Al) in bipolar configuration was implemented. A multifactorial experimental design was used for evaluating the influence of several parameters including: type and arrangement of electrodes, pH, and current density. Oil and grease removal was defined as the response variable for the statistical analysis. Additionally, the BOD(5), COD, and TOC were monitored during the treatment process. According to the results, at the optimum parameter values (current density = 4.3 mA/cm(2), distance between electrodes = 1.5 cm, Fe as anode, and pH = 12) it was possible to reach a c.a. 95% oils removal, COD and mineralization of 87.4% and 70.6%, respectively. A final biodegradability (BOD(5)/COD) of 0.54 was reached.

  18. Parametric and energy consumption optimization of Basic Red 2 removal by electrocoagulation/egg shell adsorption coupling using response surface methodology in a batch system.

    PubMed

    de Carvalho, Helder Pereira; Huang, Jiguo; Zhao, Meixia; Liu, Gang; Yang, Xinyu; Dong, Lili; Liu, Xingjuan

    2016-01-01

    In this study, response surface methodology (RSM) model was applied for optimization of Basic Red 2 (BR2) removal using electrocoagulation/eggshell (ES) coupling process in a batch system. Central composite design was used to evaluate the effects and interactions of process parameters including current density, reaction time, initial pH and ES dosage on the BR2 removal efficiency and energy consumption. The analysis of variance revealed high R(2) values (≥85%) indicating that the predictions of RSM models are adequately applicable for both responses. The optimum conditions when the dye removal efficiency of 93.18% and energy consumption of 0.840 kWh/kg were observed were 11.40 mA/cm(2) current density, 5 min and 3 s reaction time, 6.5 initial pH and 10.91 g/L ES dosage.

  19. Kinetics, isothermal and thermodynamics studies of electrocoagulation removal of basic dye rhodamine B from aqueous solution using steel electrodes

    NASA Astrophysics Data System (ADS)

    Adeogun, Abideen Idowu; Balakrishnan, Ramesh Babu

    2017-07-01

    Electrocoagulation was used for the removal of basic dye rhodamine B from aqueous solution, and the process was carried out in a batch electrochemical cell with steel electrodes in monopolar connection. The effects of some important parameters such as current density, pH, temperature and initial dye concentration, on the process, were investigated. Equilibrium was attained after 10 min at 30 °C. Pseudo-first-order, pseudo-second-order, Elovich and Avrami kinetic models were used to test the experimental data in order to elucidate the kinetic adsorption process; pseudo-first-order and Avrami models best fitted the data. Experimental data were analysed using six model equations: Langmuir, Freudlinch, Redlich-Peterson, Temkin, Dubinin-Radushkevich and Sips isotherms and it was found that the data fitted well with Sips isotherm model. The study showed that the process depends on current density, temperature, pH and initial dye concentration. The calculated thermodynamics parameters (Δ G°, Δ H° and Δ S°) indicated that the process is spontaneous and endothermic in nature.

  20. Physicochemical treatments of anionic surfactants wastewater: Effect on aerobic biodegradability.

    PubMed

    Aloui, Fathi; Kchaou, Sonia; Sayadi, Sami

    2009-05-15

    The effect of different physicochemical treatments on the aerobic biodegradability of an industrial wastewater resulting from a cosmetic industry has been investigated. This industrial wastewater contains 11423 and 3148mgL(-1) of chemical oxygen demand (COD) and anionic surfactants, respectively. The concentration of COD and anionic surfactants were followed throughout the diverse physicochemical treatments and biodegradation experiments. Different pretreatments of this industrial wastewater using chemical flocculation process with lime and aluminium sulphate (alum), and also advanced oxidation process (electro-coagulation (Fe and Al) and electro-Fenton) led to important COD and anionic surfactants removals. The best results were obtained using electro-Fenton process, exceeding 98 and 80% of anionic surfactants and COD removals, respectively. The biological treatment by an isolated strain Citrobacter braakii of the surfactant wastewater, as well as the pretreated wastewater by the various physicochemical processes used in this study showed that the best results were obtained with electro-Fenton pretreated wastewater. The characterization of the treated surfactant wastewater by the integrated process (electro-coagulation or electro-Fenton)-biological showed that it respects Tunisian discharge standards.

  1. Application of a hybrid Electrocoagulation-Fenton process in yarn dye wastewater: Kinetic study

    NASA Astrophysics Data System (ADS)

    Riadi, L.; Sapei, L.; Lidiawati, T.; Agustin, Y. E.

    2016-11-01

    Reactive dyes contain a significant portion of colorants used in yarn dying process and also in textile industry. Since the COD content is usually high in such wastewater,we conducted a hybrid electrocoagulation-fenton method to treat the wastewater. This work describes the application of the hybrid system to the removal of chemical oxygen demand and color from the wastewater in a batch reactor. Having worked with initial pH of 3,0; temperature at 30°C, molar ratio of Fe2+/H2O2 =1/10 and the mol ratio H2O2/COD = 4, we got 88.3% COD conversion and 88.5% color removal. The COD degradation process can be explained in two phases, the first phase is instantaneous reaction and the second phase is first order reaction. The kinetic constant was 0.0053 minute-1 and the rate of COD degradation was 0.0053[COD] mg/L minute.

  2. Sizes of particles formed during municipal wastewater treatment.

    PubMed

    Lech, Smoczynski; Marta, Kosobucka; Michal, Smoczynski; Harsha, Ratnaweera; Krystyna, Pieczulis-Smoczynska

    2017-02-01

    Volumetric diameters Dv and specific surface area SpS of sludge particles formed during chemical coagulation and electrocoagulation of sewage were determined. The obtained aggregate-flocs differed substantially in both Dv and SpS values. The differences in Dv and SpS values of the analyzed particles were interpreted based on theoretical models for expanding aggregates. The most uniform particles were formed under exposure to: (a) optimal and maximal doses of PIX, (b) optimal doses of PAX, (c) maximal doses of the Al electro-coagulant. The lowest PIX dose produced the least uniform particles. Sludge aggregates-particles produced under exposure to minimal doses of PIX and the Al electro-coagulant were characterized by the lowest SpS values. Sludge particles coagulated by PAX and the particles formed at higher doses of PIX and the Al electro-coagulant had higher SpS values. The particles formed at all doses of the applied coagulants and electro-coagulants were generally classified into two size ranges: the main range and the secondary range. Most particles belonged to the main size range. An increase in the percentage of colloidal hydroxide particles in sewage sludge increased SpS.

  3. Hysteroscopic tubal electrocoagulation versus laparoscopic tubal ligation for patients with hydrosalpinges undergoing in vitro fertilization.

    PubMed

    El-Mazny, Akmal; Abou-Salem, Nermeen; Hammam, Mohamed; Saber, Walid

    2015-09-01

    To investigate the use and success rate of hysteroscopic tubal electrocoagulation for the treatment of hydrosalpinx-related infertility among patients undergoing in vitro fertilization (IVF) who have laparoscopic contraindications. A prospective study was conducted among patients who had unilateral or bilateral hydrosalpinges identified on hysterosalpingography and vaginal ultrasonography, and who were undergoing IVF at a center in Cairo, Egypt, between January 1, 2013, and October 30, 2014. All patients who had contraindications for laparoscopy were scheduled for hysteroscopic tubal electrocoagulation (group 1); the other patients underwent laparoscopic tubal ligation (group 2). For all patients, hysterosalpingography was performed 3 months after their procedure to evaluate proximal tubal occlusion. Among 85 enrolled patients, 22 underwent hysteroscopic tubal electrocoagulation and 63 underwent laparoscopic tubal ligation. The procedure was successful in terms of tubal occlusion for 25 (93%) of 27 hydrosalpinges in group 1, and 78 (96%) of 81 hydrosalpinges in group 2 (P=0.597). No intraoperative or postoperative complications were reported. Hysteroscopic tubal electrocoagulation was found to be a successful treatment for hydrosalpinges before IVF when laparoscopy is contraindicated. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  4. A case of reccuring giant condyloma of vulva in infant without sexual abuse successfully treated with electrocoagulation in Benin

    PubMed Central

    Akpadjan, Fabrice; Adégbidi, Hugues; Attinsounon, Cossi Angelo; Koudoukpo, Christiane; Dégboé, Bérénice; Agbessi, Nadège; Atadokpèdé, Félix

    2017-01-01

    We report here a case of giant vulval condyloma in a two-year-old infant infected by her “baby sitter” without sexual abuse. Treated by surgical excision coupled with electrocoagulation, it was noted a rapid recurrence two weeks after treatment requiring a second electrocoagulation session. More than a year later, no lesion was noted, thus demonstrating therapeutic success. The unavailability of imiquimod in our context requires a systematic use of invasive treatment regardless of the age of the patient. PMID:28904687

  5. A case of reccuring giant condyloma of vulva in infant without sexual abuse successfully treated with electrocoagulation in Benin.

    PubMed

    Akpadjan, Fabrice; Adégbidi, Hugues; Attinsounon, Cossi Angelo; Koudoukpo, Christiane; Dégboé, Bérénice; Agbessi, Nadège; Atadokpèdé, Félix

    2017-01-01

    We report here a case of giant vulval condyloma in a two-year-old infant infected by her "baby sitter" without sexual abuse. Treated by surgical excision coupled with electrocoagulation, it was noted a rapid recurrence two weeks after treatment requiring a second electrocoagulation session. More than a year later, no lesion was noted, thus demonstrating therapeutic success. The unavailability of imiquimod in our context requires a systematic use of invasive treatment regardless of the age of the patient.

  6. Evaluation of electrosurgical interference to low-power spread-spectrum local area net transceivers.

    PubMed

    Gibby, G L; Schwab, W K; Miller, W C

    1997-11-01

    To study whether an electrosurgery device interferes with the operation of a low-power spread-spectrum wireless network adapter. Nonrandomized, unblinded trials with controls, conducted in the corridor of our institution's operating suite using two portable computers equipped with RoamAbout omnidirectional 250 mW spread-spectrum 928 MHz wireless network adapters. To simulate high power electrosurgery interference, a 100-watt continuous electrocoagulation arc was maintained five feet from the receiving adapter, while device reported signal to noise values were measured at 150 feet and 400 feet distance between the wireless-networked computers. At 150 feet range, and with continuous 100-watt electrocoagulation arc five feet from one computer, error-corrected local area net throughput was measured by sending and receiving a large file multiple times. The reported signal to noise (N = 50) decreased with electrocoagulation from 36.42+/-3.47 (control) to 31.85+/-3.64 (electrocoagulation) (p < 0.001) at 400 feet inter-adapter distance, and from 64.53+/-1.43 (control) to 60.12+/-3.77 (electrocoagulation) (p < 0.001) at 150 feet inter-adapter distance. There was no statistically significant change in network throughput (average 93 kbyte/second) at 150 feet inter-adapter distance, either transmitting or receiving during continuous 100 Watt electrocoagulation arc. The manufacturer indicates "acceptable" performance will be obtained with signal to noise values as low as 20. In view of this, while electrocoagulation affects this spread spectrum network adapter, the effects are small even at 400 feet. At a distance of 150 feet, no discernible effect on network communications was found, suggesting that if other obstructions are minimal, within a wide range on one floor of an operating suite, network communications may be maintained using the technology of this wireless spread spectrum network adapter. The impact of such adapters on cardiac pacemakers should be studied. Wireless spread spectrum network adapters are an attractive technology for mobile computer communications in the operating room.

  7. Neurochemical Mechanisms Mediating Recovery of Function.

    DTIC Science & Technology

    1984-11-01

    and hippocampus following physical ( electrocoagulation ) and chemical (ibotenic acid) destruction of the Ch neurons in the nucleus basalis...contains magnocellular Ch neurons which project primarily to ipsilateral neocortex (14). The destruction of these Ch neurons by electrocoagulation (16

  8. Reduction of pollutants and disinfection of industrial wastewater by an integrated system of copper electrocoagulation and electrochemically generated hydrogen peroxide.

    PubMed

    Barrera-Díaz, Carlos E; Frontana-Uribe, Bernardo A; Roa-Morales, Gabriela; Bilyeu, Bryan W

    2015-01-01

    The objective of this study was to evaluate the effect of copper electrocoagulation and hydrogen peroxide on COD, color, turbidity, and bacterial activity in a mixed industry wastewater. The integrated system of copper electrocoagulation and hydrogen peroxide is effective at reducing the organic and bacterial content of industrial wastewater. The copper electrocoagulation alone reduces COD by 56% in 30 min at pH 2.8, but the combined system reduces COD by 78%, biochemical oxygen demand (BOD5) by 81%, and color by 97% under the same conditions. Colloidal particles are flocculated effectively, as shown by the reduction of zeta potential and the 84% reduction in turbidity and 99% reduction in total solids. Additionally, the total coliforms, fecal coliforms, and bacteria are all reduced by 99%. The integrated system is effective and practical for the reduction of both organic and bacterial content in industrial wastewater.

  9. Bipolar electrocoagulation on cortex after AVMs lesionectomy for seizure control.

    PubMed

    Cao, Yong; Wang, Rong; Yang, Lijun; Bai, Qin; Wang, Shuo; Zhao, Jizong

    2011-01-01

    The findings of previous studies remain controversial on the optimal management required for effective seizure control after surgical excision of arteriovenous malformations (AVMs). We evaluated the efficacy of additional bipolar electrocoagulation on the electrically positive cortex guided by intraoperative electrocorticography (ECoG) for controlling cerebral AVMs-related epilepsy. Sixty consecutive patients with seizure due to cerebral AVMs, who underwent surgical excision of cerebral AVMs and intraoperative ECoG, were assessed. The AVMs and surrounding hemosiderin stained tissue were completely removed, and bipolar electrocoagulation was applied on the surrounding cerebral cortex where epileptic discharges were monitored via intraoperative ECoG. Patients were followed up at three to six months after the surgery and then annually. We evaluated seizure outcome by using Engel's classification and postoperative complications. Forty-nine patients (81.6%) were detected of epileptic discharges before and after AVMs excision. These patients underwent the removal of AVMs plus bipolar electrocoagulation on spike-positive site cortex. After electrocoagulation, 45 patients' epileptic discharges disappeared, while four obviously diminished. Fifty-five of 60 patients (91.7%) had follow-up lasting at least 22 months (mean 51.1 months; range 22-93 months). Determined by the Engel Seizure Outcome Scale, 39 patients (70.9%) were Class I, seven (12.7%) Class II, five (9.0%) Class III, and four (7.2%) Class IV. Even after the complete removal of AVM and surrounding gliotic and hemosiderin stained tissue, a high-frequency residual spike remained on the surrounding cerebral cortex. Effective surgical seizure control can be achieved by carrying out additional bipolar electrocoagulation on the cortex guided by the intraoperative ECoG.

  10. A combination of electro-enzymatic catalysis and electrocoagulation for the removal of endocrine disrupting chemicals from water.

    PubMed

    Zhao, He; Zhang, Di; Du, Penghui; Li, Haitao; Liu, Chenming; Li, Yuping; Cao, Hongbin; Crittenden, John C; Huang, Qingguo

    2015-10-30

    We in this study investigated a novel electrochemical approach combining electro-enzyme and electrocoagulation to precipitate bisphenol A (BPA) from water containing humic acid (HA). Horseradish peroxidase was immobilized on the graphite felt of Ti electrode as HRP-GF/Ti cathode, with aluminum plate anode establishing a pair of working electrodes. BPA was 100% removed and the reduction of total organic carbon (TOC) reached 95.1% after 20-min sequencing treatment with the current density of 2.3 mA/cm(2). Real wastewater (TOC=28.76 mg/L, BPA=4.1 μg/L) also can achieve 94% BPA removal and 52% TOC reduction after sequencing treatment. Additionally, coupled electro-system with continuous flow only required energy of 0.016 kWh/m(3) to achieve simultaneous 90% BPA and 85% TOC removal. As indicated in the time-of-flight mass spectrometry and FTIR spectra, the electro-enzymatic process not only oxidized BPA into dimer and BPA-3,4-quinone, but also greatly altered the chemical and structural features of HA, where hydrophilic moieties (phenolic and alcohols) transformed into hydrophobic forms (ethers, quinone and aliphatic). These polymerized products were effectively separated from aquous solution during anodic electrocoagulation, leading to significant removal of BPA and TOC. Thus, the coupled process may provide a faster and less energy strategy to control certain emerging contaminants in water/wastewater treatment. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. General Electropharmaceutical Anesthesia (Point Electroanesthesia).

    DTIC Science & Technology

    1980-07-01

    effect such as muscle contractures of trunk, limbs or face, or abnormal bleeding. The use of electrocoagulation did not provoke any change in wave...was noted. figure 9 - the electrocoagulation wave . . . . .... ... .. . . . . . .7 €. 21 .. The analgesic effect of current was studied by comparing the

  12. GENERAL ENVIRONMENTAL CORPORATION; CURE ELECTROCOAGULATION TECHNOLOGY: INNOVATIVE TECHNOLOGY EVALUATION REPORT

    EPA Science Inventory

    The CURE electrocoagulation technology was demonstrated under the Superfund Innovative Technology Evaluation (SITE) program at the U.S. Department of Energy (DOE) Rocky Flats Environmental Technology Site (RFETS), where water from the solar evaporation ponds (SEPs) was contaminat...

  13. Effect of Humic Acid on the Removal of Chromium(VI) and the Production of Solids in Iron Electrocoagulation.

    PubMed

    Pan, Chao; Troyer, Lyndsay D; Liao, Peng; Catalano, Jeffrey G; Li, Wenlu; Giammar, Daniel E

    2017-06-06

    Iron-based electrocoagulation can be highly effective for Cr(VI) removal from water supplies. However, the presence of humic acid (HA) inhibited the rate of Cr(VI) removal in electrocoagulation, with the greatest decreases in Cr(VI) removal rate at higher pH. This inhibition was probably due to the formation of Fe(II) complexes with HA that are more rapidly oxidized than uncomplexed Fe(II) by dissolved oxygen, making less Fe(II) available for reduction of Cr(VI). Close association of Fe(III), Cr(III), and HA in the solid products formed during electrocoagulation influenced the fate of both Cr(III) and HA. At pH 8, the solid products were colloids (1-200 nm) with Cr(III) and HA concentrations in the filtered fraction being quite high, while at pH 6 these concentrations were low due to aggregation of small particles. X-ray diffraction and X-ray absorption fine structure spectroscopy indicated that the iron oxides produced were a mixture of lepidocrocite and ferrihydrite, with the proportion of ferrihydrite increasing in the presence of HA. Cr(VI) was completely reduced to Cr(III) in electrocoagulation, and the coordination environment of the Cr(III) in the solids was similar regardless of the humic acid loading, pH, and dissolved oxygen level.

  14. A closed-loop biorefining system to convert organic residues into fuels

    NASA Astrophysics Data System (ADS)

    Chen, Rui

    This project delivers an energy positive and water neutral, closed-loop biorefining system that converts organic wastes into renewable energy and reduces the overall impacts on the environment. The research consisted of three major stages: The first stage of this project was conducted in an anaerobic co-digestion system. Effects of the ratio of dairy manure-to-food waste as well as operating temperature were tested on the performance of the co-digestion system. Results illustrated an increase in biogas productivity with the increase of supplemental food waste; fiber analysis revealed similar chemical composition (cellulose, hemicellulose and lignin) of final solid digestate regardless their different initial feedstock blends and digestion conditions. The molecular genetic analyses demonstrated that anaerobic methanogenic microorganisms were able to adjust their community assemblage to maximize biogas production and produce homogenized solid digestate. The second stage utilized electrocoagulation (EC) pretreated liquid digestate from previous stage to culture freshwater algae. Kinetics study showed a similar maximum growth rate (0.201-0.207 g TS day-1) in both 2x and 5x dilutions of EC solution; however, the algal growth was inhibited in original EC solution (1x), possibly due to the high ammonia-to-phosphate ratio. Algal community assemblage changed drastically in different dilutions of EC solution after a 9-day culture. The following semi-continuous culture in 2x and 5x EC media established steady biomass productivities and nitrogen removal rates; in addition, both conditions illustrated a phenomenon of phosphorus luxury uptake. Biomass composition analyses showed that algae cultured in medium containing higher nitrogen (2x EC medium) accumulated more protein but less carbohydrate and lipid than the 5x EC medium. The last stage involved hydrolyzing the algal biomass cultured in anaerobic digestion effluent and analyzing the effects of the neutralized algal hydrolysate on the performance of enzymatic hydrolysis of acid or alkali pretreated lignocelluosic substrates (poplar, corn stover, switchgrass, and solid fiber from anaerobic digestion). Results found that algal hydrolysate significantly improved the efficiency of enzymatic hydrolysis of lignin-rich, structurally recalcitrant biomass such as poplar and solid fiber from anaerobic digestion. This discovery broadened the potential application of algal biomass besides direct use for biofuel production.

  15. Treatment of pulp and paper industry bleaching effluent by electrocoagulant process.

    PubMed

    Sridhar, R; Sivakumar, V; Prince Immanuel, V; Prakash Maran, J

    2011-02-28

    The experiments were carried out in an electrocoagulation reactor with aluminum as sacrificial electrodes. The influence of electrolysis time, current density, pH, NaCl concentration, rotational speed of the stirrer and electrode distance on reduction of color, COD and BOD were studied in detail. From the experimental results, 15 mA/cm(2) current density, pH of 7, 1 g/l NaCl, 100 rpm, 28°C temperature and 3 cm electrode distance were found to be optimum for maximum reduction of color, COD and BOD. The reduction of color, COD and BOD under the optimum condition were found to be 94%, 90% and 87% respectively. The electrode energy consumption was calculated and found to be varied from 10.1 to 12.9 kWh/m(3) depending on the operating conditions. Under optimal operating condition such as 15 mA/cm(2) current density, pH of 7, 1 g/l NaCl, 100 rpm, 28°C temperature and 3 cm electrode distance, the operating cost was found to be 1.56 US $/m(3). The experimental results proved that the electrocoagulation is a suitable method for treating bleaching plant effluents for reuse. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Treatment of oily bilge water by electrocoagulation process using aluminum electrodes

    NASA Astrophysics Data System (ADS)

    Soeprijanto, Perdani, Adela Dea; Nury, Dennis Farina; Pudjiastuti, Lily

    2017-05-01

    Electrocoagulation is electrochemical water and wastewater treatment technology which is the simplest technology using an electrochemical cell where the supply of DC power is applied to the electrodes, made of aluminum metals, and the electrolyte is oily bilge water. The electrocoagulation of oily bilge water was experimentally conducted in a batch system. Aluminum plates with dimensions of 20 cm ×8 cm × 0.2 cm were used for electrodes and mounted vertically with a distance of 4 cm. These electrodes were then connected to the direct current power supply of 10 V and 10 A. The total area of the effective working plate was 160 cm2 when immersed at a depth of 10 cm to the solutions. The results showed that total dissolved Solids (TDS) decreased from 31.2 to 7.54 mg/l and formation of sludge increased up to 12.54 g/l with oil concentration of 50 g/l for 15 min. The largest oil removal of 99.5% was obtained using the initial oil concentration of 55 g/l and the lowest of 96.25% was obtained with the initial oil concentration of 146.04 g/l. A current density of 62.3 mA/cm2 was achieved for a maximum oil removal.

  17. Reducing electrocoagulation harvesting costs for practical microalgal biodiesel production.

    PubMed

    Dassey, Adam J; Theegala, Chandra S

    2014-01-01

    Electrocoagulation has shown potential to be a primary microalgae harvesting technique for biodiesel production. However, methods to reduce energy and electrode costs are still necessary for practical application. Electrocoagulation tests were conducted on Nannochloris sp. and Dunaliella sp. using perforated aluminium and iron electrodes under various charge densities. Aluminium electrodes were shown to be more efficient than iron electrodes when harvesting both algal species. Despite the lower harvesting efficiency, however, the iron electrodes were more energy and cost efficient. Operational costs of less than $0.03/L oil were achieved when harvesting Nannochloris sp. with iron electrodes at 35% harvest efficiency, whereas aluminium electrodes cost $0.75/L oil with 42% harvesting efficiency. Increasing the harvesting efficiencies for both aluminium and iron electrodes also increased the overall cost per litre of oil, therefore lower harvesting efficiencies with lower energy inputs was recommended. Also, increasing the culturing salinity to 2 ppt sodium chloride for freshwater Nannochloris sp. was determined practical to improve the electrocoagulation energy efficiency despite a 25% reduction in cell growth.

  18. Reduction of turbidity and chromium content of tannery wastewater by electrocoagulation process.

    PubMed

    2018-02-12

    The present study is carried out to remove the chromium and turbidity from tannery wastewater by the electrocoagulationprocess with aluminum electrodes. This experimental study is performed using a batch system. The applied pilot comprises a reactor containing two parallel metal electrodes (Al). The latter are connected as mono polar and a different potential is applied between them. Several working parameters, such as applied potential difference, electrolysis time, active electrode surface, inter-electrode distance and pH of the medium have been studied to achieve higher removal efficiency.The treatment achieved a maximum reduction of 99% for the turbidity and 93% for the chromium under the following conditions: a potential difference: 15V; electrodes surface: 45cm2, inter-electrode distance: 1cm; raw water pH (6.1) and a contact time of 90 min. Considering the obtained efficiency in the present study, electrocoagulation process has the potential to be utilized for the cost-effective removal of pollutants from wastewater.

  19. Treatment of winery wastewater by electrochemical methods and advanced oxidation processes.

    PubMed

    Orescanin, Visnja; Kollar, Robert; Nad, Karlo; Mikelic, Ivanka Lovrencic; Gustek, Stefica Findri

    2013-01-01

    The aim of this research was development of new system for the treatment of highly polluted wastewater (COD = 10240 mg/L; SS = 2860 mg/L) originating from vine-making industry. The system consisted of the main treatment that included electrochemical methods (electro oxidation, electrocoagulation using stainless steel, iron and aluminum electrode sets) with simultaneous sonication and recirculation in strong electromagnetic field. Ozonation combined with UV irradiation in the presence of added hydrogen peroxide was applied for the post-treatment of the effluent. Following the combined treatment, the final removal efficiencies of the parameters color, turbidity, suspended solids and phosphates were over 99%, Fe, Cu and ammonia approximately 98%, while the removal of COD and sulfates was 77% and 62%, respectively. A new approach combining electrochemical methods with ultrasound in the strong electromagnetic field resulted in significantly better removal efficiencies for majority of the measured parameters compared to the biological methods, advanced oxidation processes or electrocoagulation. Reduction of the treatment time represents another advantage of this new approach.

  20. Infectious papillomavirus in the vapor of warts treated with carbon dioxide laser or electrocoagulation: Detection and protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawchuk, W.S.; Weber, P.J.; Lowy, D.R.

    1989-07-01

    Papillomavirus DNA has been reported recently in the vapor (smoke plume) derived from warts treated with carbon dioxide laser; this raises concerns for operator safety. We therefore have studied a group of human and bovine warts to define further the potential risk of wart therapy and to test whether a surgical mask could reduce exposure. Half of each wart was treated with carbon dioxide laser and the other half with electrocoagulation. The vapor produced by each form of therapy was collected with a dry filter vacuum apparatus and analyzed for the presence of papillomavirus. Vapor from human plantar warts wasmore » analyzed for the presence of human papillomavirus DNA, because there is no infectivity assay for human papillomavirus. Of plantar warts treated, five of eight laser-derived vapors and four of seven electrocoagulation-derived vapors were positive for human papillomavirus DNA. Greater amounts of papillomavirus DNA were usually recovered in the laser vapor than in the electrocoagulation vapor from the same wart. Bioassay readily detected infectious bovine papillomavirus in the vapor from bovine warts treated with either modality; more virus was present in laser-derived material. A surgical mask was found capable of removing virtually all laser- or electrocoagulation-derived virus, strongly suggesting that such masks can protect operators from potential inhalation exposure to papillomavirus.« less

  1. The application of electrocoagulation for the conversion of MSWI fly ash into nonhazardous materials.

    PubMed

    Liao, Wing-Ping; Yang, Renbo; Kuo, Wei-Ting; Huang, Jui-Yuan

    2014-05-01

    This research investigated the electrocoagulation of municipal solid waste incineration (MSWI) fly ash at a liquid-to-solid ratio (L/S) of 20:1. The leachate that was obtained from this treatment was recovered for reutilization. Two different anodic electrodes were investigated, and two unit runs were conducted. In Unit I, the optimum anode was chosen, and in Unit II, the optimum anode and the recovered leachate were used to replace deionized water for repeating the same electrocoagulation experiments. The results indicate that the aluminum (Al) anode performed better than the iridium oxide (IrO2) anode. The electrocoagulation technique includes washing with water, changing the composition of the fly ash, and stabilizing the heavy metals in the ash. Washing with water can remove the soluble salts from fly ash, and the fly ash can be converted into Friedel's salt (3CaO·Al2O3·CaCl2·10H2O) under an uniform electric field and the sacrificial release of Al(+3) ions, which stabilizes the toxic heavy metals and brings the composition of the fly ash to within the regulatory limits of the toxicity characteristic leaching procedure (TCLP). Use of the Al anode to manage the MSWI fly ash and the leachate obtained from the electrocoagulation treatment is therefore feasible. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Influence of filling ratio and carrier type on organic matter removal in a moving bed biofilm reactor with pretreatment of electrocoagulation in wastewater treatment.

    PubMed

    Lopez-Lopez, C; Martín-Pascual, J; González-Martínez, A; Calderón, K; González-López, J; Hontoria, E; Poyatos, J M

    2012-01-01

    At present, there is great concern about limited water resources and water quality, which require a more advanced technology. The Moving Bed Biofilm Reactor (MBBR) has been shown to be an efficient technology for removal of organic matter and nutrients in industrial and urban wastewater treatment. However, there are some pollutants which are more difficult to remove by biological processes, so this process can be improved with additional physical and chemical treatments such as electrocoagulation, which appears to be a promising technology in electrochemical treatments. In this research, urban wastewater was treated in an MBBR plant with an electrocoagulation pre-treatment. K1 from AnoxKaldnes and AQWISE ABC5 from Aqwise were the carriers studied under three different filling ratios (20, 35, and 50%). The experimental pilot plant had four bioreactors with 20 L of operation volume and a common feed tank with 100 L of operation volume. The movement of the carriers was generated by aeration and stirrer systems. Organic matter removal was studied by analysis of soluble chemical oxygen demand (sCOD). The maximum organic matter removal in this MBBR system was 65.8% ± 1.4% and 78.4% ± 0.1% for K1 and Aqwise ABC5 carriers, respectively. Moreover, the bacterial diversity of the biofilm was studied by temperature-gradient gel electrophoresis (TGGE) of PCR-amplified partial 16S rRNA genes. 20 prominent TGGE bands were successfully reamplified and sequenced, being the predominant population: β-Proteobacteria, α-Proteobacteria, and Actinobacteria.

  3. [Evaluation of the results of surgical treatment of granuloma teleangiectodes].

    PubMed

    Bogdanowski, T; Rubisz-Brzezińska, J; Macura-Gina, M; Misiewicz, D

    1990-01-01

    In the clinic of dermatological surgery, I Department of Dermatology Silesian Medical Academy in Katowice 328 patients were treated surgically for granuloma teleangiectodes in the years 1973-1988. Two methods were used: excision of the lesion and curettage with electrocoagulation of the base of the lesion. After excision the wound was closed by approximation of its margins or local plastic procedure (285 cases) and by covering it with a free full-thickness skin graft (3 cases). Curettage and electrocoagulation was used in 43 cases, mainly due to the location of the lesion (in 90% on fingers). After granuloma excision no recurrences were observed, while after curettage and electrocoagulation recurrences developed in 20% of cases.

  4. Tolerance of Myriophyllum aquaticum to exposure of industrial wastewater pretreatment with electrocoagulation and their efficiency in the removal of pollutants.

    PubMed

    Cano-Rodríguez, Claudia Teodora; Roa-Morales, Gabriela; Amaya-Chávez, Araceli; Valdés-Arias, Ricardo Antonio; Barrera-Díaz, Carlos Eduardo; Balderas-Hernández, Patricia

    2014-01-01

    The wastewater used in this study was obtained from a treatment plant where it mixed with wastewater of 142 industries and was treated using electrocoagulation with iron electrode and phytoremediation with Myriophyllum aquaticum, likewise certain biomarkers of oxidative stress of the plant were evaluated to find out its resistance to contaminant exposure. Electrocoagulation was performed under optimum operating conditions at pH 8 and with a current density of 45.45 A m(-2) to reduce the COD by 42%, color 89% and turbidity 95%; the electrochemical method produces partial elimination of contaminants, though this was improved using phytoremediation. Thus the coupled treatment reduced the COD by 94%, color 97% and turbidity 98%. The exposure of M. aquaticum to electrocoagulated wastewater did not have an effect on the ratio of chlorophyll a/b (2.84 + 0.24); on the activity of SOD, CAT and lipoperoxidation. The results show the potential of M. aquaticum to remove contaminants from pretreated wastewater since the enzymatic system of the plants was not significantly affected.

  5. Electrocautery versus Ultracision versus LigaSure in Surgical Management of Hyperhidrosis.

    PubMed

    Divisi, Duilio; Di Leonardo, Gabriella; De Vico, Andrea; Crisci, Roberto

    2015-12-01

    The aim of the study was to evaluate the sympathectomy procedures for primary hyperhidrosis in terms of complications and effectiveness. From January 2010 to September 2012 we performed 130 sympathectomies in 65 patients, 27 males (42%) and 38 females (58%). Electrocoagulation was used in 20 procedures (15%), ultrasonic scalpel in 54 (42%), and radiofrequency dissector in 56 (43%). Seven patients (11%) underwent bilateral sympathectomy in the same surgical session, while in 58 (89%) the right surgical approach was delayed 30 days from the first procedure. We noticed 12 complications (9%): (a) chest pain in 6 patients (4 with electrocoagulation, 1 with ultrasonic scalpel, and 1 with radiofrequency dissector), which disappeared in 20 ± 1 day; (b) paresthesias in 3 electrocoagulation patients, was solved in 23 ± 5 days; (c) bradycardia in 1 ultrasonic patient, normalized in 4th postoperative hour; (d) unilateral relapse in 2 electrocoagulation patients after the second side approach, positively treated in 1 patient by resurgery in video-assisted thoracoscopy (VAT). The quality-adjusted life year and the quality of life evaluation revealed a statistically significant improvement (p = 0.02) in excessive sweating and general satisfaction after surgery, with Ultracision and LigaSure showing better findings than electrocoagulation. The latest generation devices offered greater efficacy in the treatment of hyperhidrosis, minimizing complications and facilitating the resumption of normal work and social activity of patients. Georg Thieme Verlag KG Stuttgart · New York.

  6. Highly Efficient Interception and Precipitation of Uranium(VI) from Aqueous Solution by Iron-Electrocoagulation Combined with Cooperative Chelation by Organic Ligands.

    PubMed

    Li, Peng; Zhun, Bao; Wang, Xuegang; Liao, PingPing; Wang, Guanghui; Wang, Lizhang; Guo, Yadan; Zhang, Weimin

    2017-12-19

    A new strategy combining iron-electrocoagulation and organic ligands (OGLs) cooperative chelation was proposed to screen and precipitate low concentrations (0-18.52 μmol/L) of uranium contaminant in aqueous solution. We hypothesized that OGLs with amino, hydroxyl, and carboxyl groups hydrophobically/hydrophilically would realize precuring of uranyl ion at pH < 3.0, and the following iron-electrocoagulation would achieve faster and more efficient uranium precipitation. Experimentally, the strategy demonstrated highly efficient uranium(VI) precipitation efficiency, especially with hydrophilic macromolecular OGLs. The uranium removal efficiency at optimized experimental condition reached 99.65%. The decrease of zeta potential and the lattice enwrapping between U-OGLs chelates and flocculation precursor were ascribed to the enhanced uranium precipitation activity. Uranium was precipitated as oxides of U(VI) or higher valences that were easily captured in aggregated micelles under low operation current potential. The actual uranium tailing wastewater was treated, and a satisfied uranium removal efficiency of 99.02% was discovered. After elution of the precipitated flocs, a concentrated uranium solution (up to 106.52 μmol/L) with very few other metallic impurities was obtained. Therefore, the proposed strategy could remove uranium and concentrate it concurrently. This work could provide new insights into the purification and recovery of uranium from aqueous solutions in a cost-effective and environmentally friendly process.

  7. Using electrocoagulation for metal and chelant separation from washing solution after EDTA leaching of Pb, Zn and Cd contaminated soil.

    PubMed

    Pociecha, Maja; Lestan, Domen

    2010-02-15

    Electrocoagulation with an Al sacrificial anode was tested for the separation of chelant and heavy metals from a washing solution obtained after leaching Pb (3200 mg kg(-1)), Zn (1100 mg kg(-1)), and Cd (21 mg kg(-1)) contaminated soil with EDTA. In the electrochemical process, the sacrificial anode corroded to release Al(3+) which served as coagulant for precipitation of chelant and metals. A constant current density of 16-128 mAc m(-2) applied between the Al anode and the stainless-steel cathode removed up to 95% Pb, 68% Zn and 66% Cd from the soil washing solution. Approximately half of the initial EDTA remained in the washing solution after treatment, up to 16.3% of the EDTA was adsorbed on Al coagulant and precipitated, the rest of the EDTA was degraded by anodic oxidation. In a separate laboratory-scale remediation experiment, we leached a soil with 40 mmol EDTA per kg of soil and reused the washing solution (after electrocoagulation) in a closed loop. It removed 53% of Pb, 26% of Zn and 52% of Cd from the soil. The discharge solution was clear and colourless, with pH 7.52 and 170 mg L(-1) Pb, 50 mg L(-1) Zn, 1.5 mg L(-1) Cd and 11 mM EDTA.

  8. Efficient Sorption and Removal of Perfluoroalkyl Acids (PFAAs) from Aqueous Solution by Metal Hydroxides Generated in Situ by Electrocoagulation.

    PubMed

    Lin, Hui; Wang, Yujuan; Niu, Junfeng; Yue, Zhihan; Huang, Qingguo

    2015-09-01

    Removal of environmentally persistent perfluoroalkyl acids (PFAAs), that is, perfluorooctanesulfonate (PFOS) and perfluorocarboxylic acids (PFCAs, C4 ∼ C10) were investigated through sorption on four metal hydroxide flocs generated in situ by electrocoagulation in deionized water with 10 mM NaCl as supporting electrolyte. The results indicated that the zinc hydroxide flocs yielded the highest removal efficiency with a wide range concentration of PFOA/PFOS (1.5 μM ∼ 0.5 mM) at the zinc dosage <150 mg L(-1) with the energy consumption <0.18 Wh L(-1). The sorption kinetics indicated that the zinc hydroxide flocs had an equilibrium adsorbed amount (qe) up to 5.74/7.69 mmol g(-1) (Zn) for PFOA/PFOS at the initial concentration of 0.5 mM with an initial sorption rate (v0) of 1.01 × 10(3)/1.81 × 10(3) mmol g(-1) h(-1). The sorption of PFOA/PFOS reached equilibrium within <10 min. The sorption mechanisms of PFAAs on the zinc hydroxide flocs were proposed based on the investigation of various driving forces. The results indicated that the hydrophobic interaction was primarily responsible for the PFAAs sorption. The electrocoagulation process with zinc anode may have a great potential for removing PFAAs from industrial wastewater as well as contaminated environmental waterbody.

  9. Severe hematuria after transurethral electrocoagulation in a patient with an arteriovesical fistula

    PubMed Central

    2013-01-01

    Background Arteriovesical fistulas are extremely rare. Only eleven cases were previously reported in the literature. They can occur iatrogenically, traumatically or spontaneously. Case presentation We report an unusual case of a 62-year-old woman with arteriovesical fistula that developed fatal hematuria after transurethral electrocoagulation. Computed tomography (CT) and selective angiography revealed a pseudoaneurysm of the right superior vesical artery with arteriovesical fistula formation, which was managed by transarterial embolization. Conclusions Contrast enhanced CT or CT angiography should be performed when a pulsatile hemorrhage is revealed during cystoscopy. Therapeutic vesical arterial embolization should be considered as a safe and effective procedure for arteriovesical fistulas. Transurethral electrocoagulation may cause severe hematuria for pulsatile bladder bleeding in patients with pelvic vascular malformation. PMID:24289138

  10. Severe hematuria after transurethral electrocoagulation in a patient with an arteriovesical fistula.

    PubMed

    Zheng, Xiangyi; Lin, Yiwei; Chen, Bin; Zhou, Xianyong; Zhou, Xiaofeng; Shen, Yuehong; Xie, Liping

    2013-12-01

    Arteriovesical fistulas are extremely rare. Only eleven cases were previously reported in the literature. They can occur iatrogenically, traumatically or spontaneously. We report an unusual case of a 62-year-old woman with arteriovesical fistula that developed fatal hematuria after transurethral electrocoagulation. Computed tomography (CT) and selective angiography revealed a pseudoaneurysm of the right superior vesical artery with arteriovesical fistula formation, which was managed by transarterial embolization. Contrast enhanced CT or CT angiography should be performed when a pulsatile hemorrhage is revealed during cystoscopy. Therapeutic vesical arterial embolization should be considered as a safe and effective procedure for arteriovesical fistulas. Transurethral electrocoagulation may cause severe hematuria for pulsatile bladder bleeding in patients with pelvic vascular malformation.

  11. The effects of chemical coagulants on the decolorization of dyes by electrocoagulation using response surface methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Butler, Erick B.; Hung, Yung-Tse; Mulamba, Oliver

    2017-09-01

    This study assessed the efficiency of electrocoagulation (ECF) coupled with an addition of chemical coagulant to decolorize textile dye. Tests were conducted using Box Behnken methodology to vary six parameters: dye type, weight, coagulant type, dose, initial pH and current density. The combination of electrocoagulation and chemical coagulation was able to decolorize dye up to 99.42 % in 30 min of treatment time which is remarkably shorter in comparison with using conventional chemical coagulation. High color removal was found to be contingent upon the dye type and current density, along with the interactions between the current density and the coagulant dose. The addition of chemical coagulants did enhanced treatment efficiency.

  12. An integrated electrocoagulation-phytoremediation process for the treatment of mixed industrial wastewater.

    PubMed

    Cano, Rodríguez Claudia Teodora; Amaya-Chávez, Araceli; Roa-Morales, Gabriela; Barrera-Díaz, Carlos Eduardo; Ureña-Núñez, Fernando

    2010-01-01

    The elimination of organic contaminants in highly complex wastewater was tested using a combination of the techniques: electrocoagulation with aluminum electrodes and phytoremediation with Myriophyllum aquaticum. Under optimal operating conditions at a pH of 8 and a current density of 45.45 A m(-2), the electrochemical method produces partial elimination of contaminants, which was improved using phytoremediation as a polishing technique. The combined treatment reduced chemical oxygen demand (COD) by 91%, color by 97% and turbidity by 98%. Initial and final values of contaminants in wastewaters were monitored using UV-vis spectrometry and cyclic voltammetry. Finally, the morphology and the elemental composition of the biomass were characterized with using scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS). The presence of Al in the roots of plants in the system indicates that the aluminum present in the test solution could be absorbed.

  13. Vital pulp therapy with bipolar electrocoagulation after intentional pulp exposure of fixed prosthodontic abutments: a clinical report.

    PubMed

    Livaditis, G J

    2001-10-01

    A clinical protocol is described for the treatment of intentional and unavoidable exposed pulps during crown preparation. The protocol includes a definitive cavity preparation to create space in the exposed dentin for an adhesive pulp barrier; procedures to develop the highly desirable hybrid zone to prevent microleakage; the use of a specific resinous material that serves as a long-term pulp barrier with a relatively neutral and biocompatible impact on the pulp; and the use of precise bipolar electrocoagulation to provide durable hemostasis for restoration of the pulp wall and a relatively clot-free surgical wound to facilitate healing. The protocol involves the application of gentle surgical and restorative procedures to support the inherent healing process to restore the health of the pulp. The patient presented was part of a larger investigation and was selected in an attempt to identify a fixed prosthodontic application of the proposed pulp therapy protocol.

  14. Techno-economical optimization of Reactive Blue 19 removal by combined electrocoagulation/coagulation process through MOPSO using RSM and ANFIS models.

    PubMed

    Taheri, M; Alavi Moghaddam, M R; Arami, M

    2013-10-15

    In this research, Response Surface Methodology (RSM) and Adaptive Neuro Fuzzy Inference System (ANFIS) models were applied for optimization of Reactive Blue 19 removal using combined electrocoagulation/coagulation process through Multi-Objective Particle Swarm Optimization (MOPSO). By applying RSM, the effects of five independent parameters including applied current, reaction time, initial dye concentration, initial pH and dosage of Poly Aluminum Chloride were studied. According to the RSM results, all the independent parameters are equally important in dye removal efficiency. In addition, ANFIS was applied for dye removal efficiency and operating costs modeling. High R(2) values (≥85%) indicate that the predictions of RSM and ANFIS models are acceptable for both responses. ANFIS was also used in MOPSO for finding the best techno-economical Reactive Blue 19 elimination conditions according to RSM design. Through MOPSO and the selected ANFIS model, Minimum and maximum values of 58.27% and 99.67% dye removal efficiencies were obtained, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Wastewater quality monitoring system using sensor fusion and machine learning techniques.

    PubMed

    Qin, Xusong; Gao, Furong; Chen, Guohua

    2012-03-15

    A multi-sensor water quality monitoring system incorporating an UV/Vis spectrometer and a turbidimeter was used to monitor the Chemical Oxygen Demand (COD), Total Suspended Solids (TSS) and Oil & Grease (O&G) concentrations of the effluents from the Chinese restaurant on campus and an electrocoagulation-electroflotation (EC-EF) pilot plant. In order to handle the noise and information unbalance in the fused UV/Vis spectra and turbidity measurements during the calibration model building, an improved boosting method, Boosting-Iterative Predictor Weighting-Partial Least Squares (Boosting-IPW-PLS), was developed in the present study. The Boosting-IPW-PLS method incorporates IPW into boosting scheme to suppress the quality-irrelevant variables by assigning small weights, and builds up the models for the wastewater quality predictions based on the weighted variables. The monitoring system was tested in the field with satisfactory results, underlying the potential of this technique for the online monitoring of water quality. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Optimizing TOC and COD removal for the biodiesel wastewater by electrocoagulation

    NASA Astrophysics Data System (ADS)

    Tanattı, N. Pınar; Şengil, İ. Ayhan; Özdemir, Abdil

    2018-05-01

    In this study, the chemical oxygen demand (COD) and the total organic carbon content (TOC) in biodiesel wastewater iron and aluminum electrodes arranged in a bipolar position. In the EC of the biodiesel wastewater, the effects of the supporting electrolyte, initial pH, electrolysis time and current density were examined. The results showed that the majority of the pollutants in the biodiesel wastewater were effectively removed when the iron or aluminum electrodes were used as a sacrificial anode. The highest COD and TOC removal efficiencies were successfully obtained with the iron electrode. COD removal efficiencies are 91.74 and 90.94% for iron and aluminum electrode, respectively. In the same way, TOC removal efficiencies were obtained as 91.79 and 91.98% for the iron and aluminum electrodes, respectively, at initial pH of 6, the current density of 0.3226 mA/cm2, NaCl concentration 1 g/L and 1 min of operating time.

  17. Relative insignificance of virus inactivation during aluminum electrocoagulation of saline waters.

    PubMed

    Tanneru, Charan Tej; Jothikumar, N; Hill, Vincent R; Chellam, Shankararaman

    2014-12-16

    Combined removal and inactivation of the MS2 bacteriophage from model saline (0-100 mM NaCl) waters by electrochemical treatment using a sacrificial aluminum anode was evaluated. Both chemical and electrodissolution contributed to coagulant dosing since measured aluminum concentrations were statistically higher than purely electrochemical predictions using Faraday's law. Electrocoagulation generated only small amounts of free chlorine in situ but effectively destabilized viruses and incorporated them into Al(OH)3(s) flocs during electrolysis. Low chlorine concentrations combined with virus shielding and aggregation within flocs resulted in very slow disinfection rates necessitating extended flocculation/contact times to achieve significant log-inactivation. Therefore, the dominant virus control mechanism during aluminum electrocoagulation of saline waters is "physical" removal by uptake onto flocs rather than "chemical" inactivation by chlorine. Attenuated total reflectance-Fourier transform infrared spectroscopy provided evidence for oxidative transformations of capsid proteins including formation of oxyacids, aldehydes, and ketones. Electrocoagulation significantly altered protein secondary structures decreasing peak areas associated with turns, bends, α-helices, β-structures, and random coils for inactivated viruses compared with the MS2 stock. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) measurements showed rapid initial RNA damage following a similar trend as plaque assay measurements of infectious viruses. However, ssRNA cleavage measured by qRT-PCR underestimated inactivation over longer durations. Although aluminum electrocoagulation of saline waters disorders virus capsids and damages RNA, inactivation occurs at a sufficiently low rate so as to only play a secondary role to floc-encapsulation during residence times typical of electrochemical treatment.

  18. [Electrocoagulation on a fragment of anterior abdominal rectal muscle for the control of presacral bleeding during rectal resection].

    PubMed

    Casal Núñez, José Enrique; Martínez, María Teresa García; Poblador, Alejandro Ruano

    2012-03-01

    Presacral venous haemorrhage during rectal movement is low, but is often massive, and even fatal. Our objective is the "in vitro" determination of the results of electrocoagulation applied to a fragment of muscle on the sacral bone surface during rectal resection due to a malignant neoplasm of the rectum. Single-pole coagulation was applied "in vitro" with the selector at maximum power on a 2×2 cms muscle fragment, applied to the anterior side of the IV sacral vertebra until reaching boiling point. The method was used on 6 patients with bleeding of the presacral venous plexus. In the "in vitro" study, boiling point was reached in 90 seconds from applying the single-pole current on the muscle fragment. Electrocoagulation was applied to a 2×2 cm rectal muscle fragment in 6 patients with presacral venous haemorrhage, using pressure on the surface of the presacral bone, with the stopping of the bleeding being achieved in all cases. The use of indirect electrocoagulation on a fragment of the rectus abdominis muscle is a straightforward and highly effective technique for controlling presacral venous haemorrhage. Copyright © 2011 AEC. Published by Elsevier Espana. All rights reserved.

  19. Laparoscopic surgery in the treatment of nonruptured tubal pregnancy

    NASA Astrophysics Data System (ADS)

    Mutrynowski, Andrzej; Zabielska, Renata

    1996-03-01

    Introduction of the endoscopic techniques into gynecology enabled a change in the procedures in the case of ectopic pregnancy. This paper aims at presenting 76 cases of non-ruptured tubal pregnancies treated conservatively by the laparoscopic surgery with the application of the electrocoagulation or the Nd:YAG laser. The investigated group consisted of 76 patients. Forty-one (54%) of them were operated on using electrocoagulation and 35 (46%) using the Nd:YAG laser. Sixty-three pregnancies (83%) were localized in the ampulla. The ectopic pregnancy was confirmed histopathologically in 74 cases (97%). There were no complications noticed in the postoperative course. There were no differences in the efficacy and the postoperative general condition in cases treated conservatively by the laparoscopic surgery with the application of the electrocoagulation or the laser.

  20. Therapeutic efficacy of narrow band imaging-assisted transurethral electrocoagulation for ulcer-type interstitial cystitis/painful bladder syndrome.

    PubMed

    Kajiwara, Mitsuru; Inoue, Shougo; Kobayashi, Kanao; Ohara, Shinya; Teishima, Jun; Matsubara, Akio

    2014-04-01

    Narrow band imaging cystoscopy can increase the visualization and detection of Hunner's lesions. A single-center, prospective clinical trial was carried out aiming to show the effectiveness of narrow band imaging-assisted transurethral electrocoagulation for ulcer-type interstitial cystitis/painful bladder syndrome. A total of 23 patients (19 women and 4 men) diagnosed as having ulcer-type interstitial cystitis/painful bladder syndrome were included. All typical Hunner's lesions and suspected areas identified by narrow band imaging were electrocoagulated endoscopically after the biopsy of those lesions. Therapeutic efficacy was assessed prospectively by using visual analog scale score of pain, O'Leary-Sant's symptom index, O'Leary-Sant's problem index and overactive bladder symptom score. The mean follow-up period was 22 months. All patients (100%) experienced a substantial improvement in pain. The average visual analog scale pain scores significantly decreased from 7.3 preoperatively to 1.2 1 month postoperatively. A total of 21 patients (91.3%) who reported improvement had at least a 50% reduction in bladder pain, and five reported complete resolution. Daytime frequency was significantly decreased postoperatively. O'Leary-Sant's symptom index, O'Leary-Sant's problem index and overactive bladder symptom score were significantly decreased postoperatively. However, during the follow-up period, a total of six patients had recurrence, and repeat narrow band imaging-assisted transurethral electrocoagulation of the recurrent lesions was carried out for five of the six patients, with good response in relieving bladder pain. Our results showed that narrow band imaging-assisted transurethral electrocoagulation could be a valuable therapeutic alternative in patients with ulcer-type interstitial cystitis/painful bladder syndrome, with good efficacy and reduction of recurrence rate. © 2014 The Japanese Urological Association.

  1. Highly selective electrocoagulation therapy: an innovative treatment for lymphangioma circumscriptum.

    PubMed

    Yang, Xi; Jin, Yunbo; Chen, Hui; Li, Suolan; Ma, Gang; Hu, Xiaojie; Qiu, Yajing; Yu, Wenxin; Chang, Lei; Wang, Tianyou; Lin, Xiaoxi

    2014-08-01

    Lymphangioma circumscriptum (LC) is a type of microcystic lymphatic malformation involving the skin and mucosa that presents as translucent vesicles of varying size with a pink, red, or black hue. Lymphangioma circumscriptum causes not only cosmetic problems but also refractory rupture, infection, lymphorrhea, and bleeding. Various invasive methods, such as surgical excision, lasers, and sclerotherapy, have been used in the past to treat LC with varying success. Herein, we report a new treatment for the management of LC. This study reports the outcomes of 12 patients (aged 4-31 years) with LC treated by electrocoagulation using a special isolated needle. Patient demographics, lesion characteristics, radiologic findings, treatment course, and clinical responses are recorded. All 12 patients who were treated with the highly selective electrocoagulation therapy achieved near-complete clearance. Minimal intra- and postoperative sequelae were observed. The local complications included mild pain (n = 9), proliferous scarring (n = 1), and ulceration (n = 1) with no systemic side effects. The mean follow-up period was 8.25 months (3-14 months). Highly selective electrocoagulation therapy is an innovative, minimally invasive technique that seems to be safe and effective for the treatment of LC; the results from our limited study population seem promising, and the observed complications are acceptable.

  2. Extraction of antioxidants from olive mill wastewater and electro-coagulation of exhausted fraction to reduce its toxicity on anaerobic digestion.

    PubMed

    Khoufi, Sonia; Aloui, Fathi; Sayadi, Sami

    2008-03-01

    Liquid-liquid extraction was used in order to recover phenolic compounds from centrifuged olive mill wastewater (OMW), a polluting by-product of olive oil production process, and to reduce their toxicity for a subsequent aerobic or anaerobic digestion. Phenolic compounds were identified in untreated and treated OMW by gas chromatography coupled to mass spectrometry (GC-MS). The experimental results of ethyl acetate extraction showed that the monomers recovery efficiency was over 90%. This pre-treatment resulted in the removal of the major LMM phenolic compounds and a small part of HMM polyphenols. The aerobic treatment of the exhausted OMW fraction removed 78.7% of the soluble COD. In the case of anaerobic digestion at OLR ranged from 1 to 3.5 gCOD l(-1)day(-1), methanisation process exhibited high methane yield as 0.3 l CH4 produced per g COD introduced and high COD removal (80%). However, a disruption of the process was observed when the OLR was increased to 4.5 gCODl(-1)day(-1). A pre-treatment by electro-coagulation resulted in decreasing the toxicity and enhancing the performance of methanisation operated at higher OLR from 4 to 7.5 gCODl(-1)day(-1).

  3. Removal of natural organic matter and arsenic from water by electrocoagulation/flotation continuous flow reactor.

    PubMed

    Mohora, Emilijan; Rončević, Srdjan; Dalmacija, Božo; Agbaba, Jasmina; Watson, Malcolm; Karlović, Elvira; Dalmacija, Milena

    2012-10-15

    The performance of the laboratory scale electrocoagulation/flotation (ECF) reactor in removing high concentrations of natural organic matter (NOM) and arsenic from groundwater was analyzed in this study. An ECF reactor with bipolar plate aluminum electrodes was operated in the horizontal continuous flow mode. Electrochemical and flow variables were optimized to examine ECF reactor contaminants removal efficiency. The optimum conditions for the process were identified as groundwater initial pH 5, flow rate=4.3 l/h, inter electrode distance=2.8 cm, current density=5.78 mA/cm(2), A/V ratio=0.248 cm(-1). The NOM removal according to UV(254) absorbance and dissolved organic matter (DOC) reached highest values of 77% and 71% respectively, relative to the raw groundwater. Arsenic removal was 85% (6.2 μg As/l) relative to raw groundwater, satisfying the drinking water standards. The specific reactor electrical energy consumption was 17.5 kWh/kg Al. The specific aluminum electrode consumption was 66 g Al/m(3). According to the obtained results, ECF in horizontal continuous flow mode is an energy efficient process to remove NOM and arsenic from groundwater. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Anodic oxidation of slaughterhouse wastewater on boron-doped diamond: process variables effect.

    PubMed

    Abdelhay, Arwa; Jum'h, Inshad; Abdulhay, Enas; Al-Kazwini, Akeel; Alzubi, Mashael

    2017-12-01

    A non-sacrificial boron-doped diamond electrode was prepared in the laboratory and used as a novel anode for electrochemical oxidation of poultry slaughterhouse wastewater. This wastewater poses environmental threats as it is characterized by a high content of recalcitrant organics. The influence of several process variables, applied current density, initial pH, supporting electrolyte nature, and concentration of electrocoagulant, on chemical oxygen demand (COD) removal, color removal, and turbidity removal was investigated. Results showed that raising the applied current density to 3.83 mA/cm 2 has a positive effect on COD removal, color removal, and turbidity removal. These parameters increased to 100%, 90%, and 80% respectively. A low pH of 5 favored oxidants generation and consequently increased the COD removal percentage to reach 100%. Complete removal of COD had occurred in the presence of NaCl (1%) as supporting electrolyte. Na 2 SO 4 demonstrated lower efficiency than NaCl in terms of COD removal. The COD decay kinetics follows the pseudo-first-order reaction. The simultaneous use of Na 2 SO 4 and FeCl 3 decreased the turbidity in wastewater by 98% due to electrocoagulation.

  5. Microlaparoscopic technique for partial salpingectomy using bipolar electrocoagulation.

    PubMed

    Siegle, J C; Cartmell, L W; Rayburn, W F

    2001-07-01

    To describe a technique of performing a partial salpingectomy using a small-diameter (2-mm) laparoscope and bipolar electrocoagulation. Sixty consecutive women desiring permanent sterilization underwent laparoscopic partial salpingectomy using a 2-mm transumbilical laparoscope and secondary midline sites suprapubically and midway above the pubis. A midportion of the tube was coagulated using Kleppinger forceps, transected with scissors and removed using grasping forceps. Additional time to remove both coagulated tubal segments averaged 4 minutes (range, 3-10). Each segment (mean, 1.5 cm; range, 0.9-2.4 cm) was confirmed in the operating room, then histologically. The transected tubal edges were separated with no thermal injury to nearby structures and with no mesosalpingeal hemorrhage. No cases required conversion from microlaparoscopy to a traditional method, and recovery time was not prolonged. The puncture sites healed well without sutures. Successful removal of electrocoagulated tubal segments with histologic confirmation was undertaken microlaparoscopically, with minimal additional operative time.

  6. Destabilization and Treatment of Emulsified Oils in Wastewaters by Electrocoagulation.

    PubMed

    Genc, Ayten; Bakirci, Busra

    2016-11-01

      In this study, the optimum operating conditions for the treatment of emulsified oils by electrocoagulation were determined depending on droplet stability analysis. Zeta potential measurements were used as the indication of oil droplet charges. In addition, the effects of pH and ionic conductivity on the droplet sizes and surface charges were investigated. The studied emulsified oil droplet sizes were more sensitive to changes in pH rather than salt concentration. The droplets became larger and unstable in alkaline conditions. As the initial pH of wastewaters increased, the oil removal efficiency increased during the electrocoagulation experiments as well. The use of iron or aluminum electrodes resulted in higher removal efficiencies in comparison to stainless steel electrodes. In addition, the energy consumption for aluminum electrodes was much lower than iron electrodes. To obtain 98% oil removal efficiency, distance between the electrodes was recommended to be less than or equal to 1 cm.

  7. Comparative study of humic acid removal and floc characteristics by electrocoagulation and chemical coagulation.

    PubMed

    Semerjian, Lucy; Damaj, Ahmad; Salam, Darine

    2015-11-01

    The current study aims at investigating the efficiency of electrocoagulation for the removal of humic acid from contaminated waters. In parallel, conventional chemical coagulation was conducted to asses humic acid removal patterns. The effect of varying contributing parameters (matrix pH, humic acid concentration, type of electrode (aluminum vs. iron), current density, solution conductivity, and distance between electrodes) was considered to optimize the electrocoagulation process for the best attainable humic acid removal efficiencies. Optimum removals were recorded at pH of 5.0-5.5, an electrical conductivity of 3000 μS/cm at 25 °C, and an electrode distance of 1 cm for both electrode types. With aluminum electrodes, a current density of 0.05 mA/cm2 outperformed 0.1 mA/cm2 yet not higher densities, whereas a current density of 0.8 mA/cm2 was needed for iron electrodes to exhibit comparable performance. With both electrode types, higher initial humic acid concentrations were removed at a slower rate but ultimately attained almost complete removals. On the other hand, the best humic acid removals (∼90%) by chemical coagulation were achieved at 4 mg/L for both coagulants. Also, higher removals were attained at elevated initial humic acid concentrations. Humic acid removals of 90% or higher at an initial HA concentration of 40 mg/L were exhibited, yet alum performed better at the highest experimented concentration. It was evident that iron flocs were larger, denser, and more geometrical in shape compared to aluminum flocs.

  8. Post-polypectomy electrocoagulation syndrome: a rare cause of acute abdominal pain

    PubMed Central

    Jehangir, Asad; Bennett, Kyle M.; Rettew, Andrew C.; Fadahunsi, Opeyemi; Shaikh, Bilal; Donato, Anthony

    2015-01-01

    While generally safe, the most feared complication of colonoscopy is perforation of the colon, occurring in nearly 1 in 1,000 procedures, and is more common when polypectomy is performed and electrocautery is used. Less commonly known is the post-polypectomy electrocoagulation syndrome, a transmural burn of the colon which mimics the signs and symptoms of perforation as well as the time course, but follows a benign course and can be treated conservatively. PMID:26486121

  9. An empirical model for parameters affecting energy consumption in boron removal from boron-containing wastewaters by electrocoagulation.

    PubMed

    Yilmaz, A Erdem; Boncukcuoğlu, Recep; Kocakerim, M Muhtar

    2007-06-01

    In this study, it was investigated parameters affecting energy consumption in boron removal from boron containing wastewaters prepared synthetically, via electrocoagulation method. The solution pH, initial boron concentration, dose of supporting electrolyte, current density and temperature of solution were selected as experimental parameters affecting energy consumption. The obtained experimental results showed that boron removal efficiency reached up to 99% under optimum conditions, in which solution pH was 8.0, current density 6.0 mA/cm(2), initial boron concentration 100mg/L and solution temperature 293 K. The current density was an important parameter affecting energy consumption too. High current density applied to electrocoagulation cell increased energy consumption. Increasing solution temperature caused to decrease energy consumption that high temperature decreased potential applied under constant current density. That increasing initial boron concentration and dose of supporting electrolyte caused to increase specific conductivity of solution decreased energy consumption. As a result, it was seen that energy consumption for boron removal via electrocoagulation method could be minimized at optimum conditions. An empirical model was predicted by statistically. Experimentally obtained values were fitted with values predicted from empirical model being as following; [formula in text]. Unfortunately, the conditions obtained for optimum boron removal were not the conditions obtained for minimum energy consumption. It was determined that support electrolyte must be used for increase boron removal and decrease electrical energy consumption.

  10. Experimental design approach applied to the elimination of crystal violet in water by electrocoagulation with Fe or Al electrodes.

    PubMed

    Durango-Usuga, Paula; Guzmán-Duque, Fernando; Mosteo, Rosa; Vazquez, Mario V; Peñuela, Gustavo; Torres-Palma, Ricardo A

    2010-07-15

    An experimental design methodology was applied to evaluate the decolourization of crystal violet (CV) dye by electrocoagulation using iron or aluminium electrodes. The effects and interactions of four parameters, initial pH (3-9), current density (6-28 A m(-2)), substrate concentration (50-200 mg L(-1)) and supporting electrolyte concentration (284-1420 mg L(-1) of Na(2)SO(4)), were optimized and evaluated. Although the results using iron anodes were better than for aluminium, the effects and interactions of the studied parameters were quite similar. With a confidence level of 95%, initial pH and supporting electrolyte concentration showed limited effects on the removal rate of CV, whereas current density, pollutant concentration and the interaction of both were significant. Reduced models taking into account significant variables and interactions between variables have shown good correlations with the experimental results. Under optimal conditions, almost complete removal of CV and chemical oxygen demand were obtained after electrocoagulation for 5 and 30 min, using iron and aluminium electrodes, respectively. These results indicate that electrocoagulation with iron anodes is a rapid, economical and effective alternative to the complete removal of CV in waters. Evolutions of pH and residual iron or aluminium concentrations in solution are also discussed. 2010 Elsevier B.V. All rights reserved.

  11. In vivo layer visualization of rat olfactory bulb by a swept source optical coherence tomography and its confirmation through electrocoagulation and anatomy

    PubMed Central

    Watanabe, Hideyuki; Rajagopalan, Uma Maheswari; Nakamichi, Yu; Igarashi, Kei M.; Madjarova, Violeta Dimitrova; Kadono, Hirofumi; Tanifuji, Manabu

    2011-01-01

    Here, we report in vivo 3-D visualization of the layered organization of a rat olfactory bulb (OB) by a swept source optical coherence tomography (SS-OCT). The SS-OCT operates at a wavelength of 1334 nm with respective theoretical depth and lateral resolutions of 6.7 μm and 15.4 μm in air and hence it is possible to get a 3D structural map of OB in vivo at the micron level resolution with millimeter-scale imaging depth. Up until now, with methods such as MRI, confocal microscopy, OB depth structure in vivo had not been clearly visualized as these do not satisfy the criterion of simultaneously providing micron-scale spatial resolution and imaging up to a few millimeter in depth. In order to confirm the OB’s layered organization revealed by SS-OCT, we introduced the technique of electrocoagulation to make landmarks across the layered structure. To our knowledge this is such a first study that combines electrocoagulation and OCT in vivo of rat OB. Our results confirmed the layered organization of OB, and moreover the layers were clearly identified by electrocoagulation landmarks both in the OCT structural and anatomical slice images. We expect such a combined study is beneficial for both OCT and neuroscience fields. PMID:21833364

  12. Treatment of olive mill wastewater by chemical processes: effect of acid cracking pretreatment.

    PubMed

    Hande Gursoy-Haksevenler, B; Arslan-Alaton, Idil

    2014-01-01

    The effect of acid cracking (pH 2.0; T 70 °C) and filtration as a pretreatment step on the chemical treatability of olive mill wastewater (chemical oxygen demand (COD) 150,000 m/L; total organic carbon (TOC) 36,000 mg/L; oil-grease 8,200 mg/L; total phenols 3,800 mg/L) was investigated. FeCl3 coagulation, Ca(OH)2 precipitation, electrocoagulation using stainless steel electrodes and the Fenton's reagent were applied as chemical treatment methods. Removal performances were examined in terms of COD, TOC, oil-grease, total phenols, colour, suspended solids and acute toxicity with the photobacterium Vibrio fischeri. Significant oil-grease (95%) and suspended solids (96%) accompanied with 58% COD, 43% TOC, 39% total phenols and 80% colour removals were obtained by acid cracking-filtration pretreatment. Among the investigated chemical treatment processes, electrocoagulation and the Fenton's reagent were found more effective after pretreatment, especially in terms of total phenols removal. Total phenols removal increased from 39 to 72% when pretreatment was applied, while no significant additional (≈10-15%) COD and TOC removals were obtained when acid cracking was coupled with chemical treatment. The acute toxicity of the original olive mill wastewater sample increased considerably after pretreatment from 75 to 89% (measured for the 10-fold diluted wastewater sample). An operating cost analysis was also performed for the selected chemical treatment processes.

  13. Integrated treatment of molasses distillery wastewater using microfiltration (MF).

    PubMed

    Basu, Subhankar; Mukherjee, Sangeeta; Kaushik, Ankita; Batra, Vidya S; Balakrishnan, Malini

    2015-08-01

    To achieve zero-liquid discharge, high pressure reverse osmosis (RO) of effluent is being employed by molasses based alcohol distilleries. Low pressure and thus less energy intensive microfiltration (MF) is well established for particulate separation but is not suitable for removal of dissolved organics and color. This work investigates two schemes incorporating MF for molasses distillery wastewater (a) chemical coagulation followed by treatment in a membrane bioreactor (MBR) using MF and (b) electrocoagulation followed by MF. The performance was assessed in terms of COD and color reduction; the conversion of the generated sludge into a zeolite desiccant was also examined. A comparison of the schemes indicates electrocoagulation followed by MF through a 0.1 μm membrane to be most effective. By hydrothermal treatment, electrocoagulated sludge can be transformed into a porous NaX zeolite with a surface area of 86 m(2)/g, which is comparable to commercial desiccants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. How Frequency of Electrosurgical Current and Electrode Size Affect the Depth of Electrocoagulation.

    PubMed

    Taheri, Arash; Mansoori, Parisa; Bahrami, Naeim; Alinia, Hossein; Watkins, Casey E; Feldman, Steven R

    2016-02-01

    Many factors affect the depth of electrocoagulation. To evaluate the effect of current frequency and electrode size on the depth of electrocoagulation. In this in vitro study, 4 cylindrical electrodes (2, 2.3, 3, and 4 mm) were used to apply 3 electrosurgical currents (0.4, 1.5, and 3 MHz) to bovine liver. Each electrode was placed at different points on the surface of the liver, and energy at various levels and frequencies was delivered to the tissue. Subsequently, cross-sections of the liver were analyzed. Coagulation started at the periphery of the electrode-tissue contact area. With higher energy levels, coagulation spreads to involve the remainder of the contact area. Neither the frequency nor the electrode size had any effect on this coagulation pattern. The frequency of the current also did not show any relation with depth of coagulation; however, there was a direct correlation between the size of the electrode and the depth of coagulation. Larger-tip electrodes provided deeper coagulation compared with finer-tip electrodes.

  15. Influence of organic matter on arsenic removal by continuous flow electrocoagulation treatment of weakly mineralized waters.

    PubMed

    Pallier, Virginie; Feuillade-Cathalifaud, Geneviève; Serpaud, Bernard

    2011-03-01

    The aim of this study is to evaluate and understand the electrocoagulation/flocculation (ECF) process to remove arsenic from both model and natural waters with low mineral content and to compare its performances to the coagulation/flocculation (CF) process already optimized. Experiments were thus conducted with iron electrodes in the same specific treatment conditions (4≤current density (mAcm(-2))≤33) to study the influence of organic matter on arsenic removal in conditions avoiding the oxidation step usually required to improve As(III) removal. The process performance was evaluated by combining quantification of arsenic residual concentrations and speciation and dissolved organic carbon residual concentrations with zeta potential and turbidity measurements. When compared to CF, ECF presented several disadvantages: (i) lower As(V) removal yield because of the ferrous iron dissolved from the anode and the subsequent negative zeta potential of the colloidal suspension, (ii) higher residual DOC concentrations because of the fractionation of high molecular weight compounds during the treatment leading to compounds less prone to coagulate and (iii) higher residual turbidities because of the charge neutralization mechanisms involved. However, during this process, As(III) was oxidized to As(V) improving considerably its removal whatever the matrix conditions. ECF thus allowed to improve As(III) removal without applying an oxidation step that could potentially lead to the formation of toxic oxidation by-products. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. [High frequency electrocoagulation for treating noninvoluting congenital hemangioma].

    PubMed

    Zhongqiang, Wang; Yafei, Wang; Jiashuang, Zhou; Quan, Zhou; Lijuan, Yang; Li, Wang

    2015-11-01

    To investigate the clinical efficiency of electrocoagulation for the treatment of noninvoluting congenital hemangioma. Sixteen infants with noninvoluting congenital hemangioma who were admitted to our hospital from January 2011 to June 2013 were included in this study. Color Doppler ultrasound was used to determine the hemangioma location, as well as its size and depth. High frequency electrocoagulation was adopted for the treatment. The output power was set at 10-20 W. The probes were inserted around the tumor or at the surface of the tumor. After switching on for 1-2 seconds, the direction and position of the probe was modulated until covering the whole tumor. After the treatment, the absorption of tumor was about 3-6 months. The efficiency was evaluated during the follow-up. Tumor atrophy was obvious after treatment in all patients. The temperature around the tumor mass was decreased, and the aberrant blood signals were decreased under the ultrasonic examination. Complete or partial atrophy were observed. The efficiency was graded as level I, II, III, IV in 0, 2, 9 and 5 patients, respectively. One patient showed local infection due to improper nursing, which was completely relieved after corresponding treatment. No severe adverse events were observed. High-frequency electrocoagulation is effective for treating noninvoluting congenital hemangioma through coagulating the aberrant blood vessels in the tumor, interrupting the vascular endothelial cell, blocking the aberrant blood flow, as well as leading to atrophy and absorption of tumor mass. Besides, no obvious scar is observed after the surgery.

  17. Impact of hemostasis methods, electrocoagulation versus suture, in laparoscopic endometriotic cystectomy on the ovarian reserve: a randomized controlled trial.

    PubMed

    Tanprasertkul, Chamnan; Ekarattanawong, Sophapun; Sreshthaputra, Opas; Vutyavanich, Teraporn

    2014-08-01

    To evaluate the impact on ovarian reserve between two different methods ofhemostasis after laparoscopic ovarian endometrioma excision. A randomized controlled study was conducted from January to December 2013 in Thammasat University Hospital, Thailand. Reproductive women, age 18-45years who underwent laparoscopic ovarian cystectomy were randomized in electrocoagulation and suture groups. Clinical baseline data and ovarian reserve outcome (anti-Mullerian hormone (AMH)) were evaluated. Fifty participants were recruited and randomized in two groups. Electrocoagulation and suture groups consisted of 25 participants. Baseline characteristics between 2 groups (age, weight, BMI, height, cyst diameter, duration and estimated blood loss) were not statistically different. There were no significant difference of AMIH between electrocoagulation and suture group atpre-operative (2.90±2.26 vs. 2.52±2.37 ng/ml), 1 week (1.78±1.51 vs. 1.99±1.71 ng/ml), 1 month (1.76±1.50 vs. 2.09±1.62 ng/ml), 3 months (2.09±1.66 vs. 1.96±1.68 ng/ml) and 6 months (2.11±1.84 vs 1.72±1.68 ng/ml), respectively. However mean AMH ofboth groups significantly decreased since the first week of operation. Effect oflaparoscopic ovarian surgery had significantly declined and sustained AMH level until 6 months. Laparoscopic cystectomy of ovarian endometrioma has negative impact to ovarian reserve. Either electroco- agulation or suture method had no different effects.

  18. Electro-oxidation and characterization of nickel foam electrode for removing boron.

    PubMed

    Kartikaningsih, Danis; Huang, Yao-Hui; Shih, Yu-Jen

    2017-01-01

    The electrocoagulation (EC) using metallic Ni foam as electrodes was studied for the removal of boron from solution. The electrolytic parameters were pH (4-12), current density (0.6-2.5 mA cm -2 ), and initial concentration of boron (10-100 mg L -1 ). Experimental results revealed that removal efficiency was maximized at pH 8-9, and decreased as the pH increased beyond that range. At particular onset potentials (0.5-0.8 V vs. Hg/HgO), the micro-granular nickel oxide that was created on the surface of the nickel metal substrate depended on pH, as determined by cyclic voltammetry. Most of the crystallites of the precipitates comprised a mixed phase of β-Ni(OH) 2 , a theophrastite phase, and NiOOH, as revealed by XRD and SEM analyses. A current density of 1.25 mA cm -2 was effective in the EC of boron, and increasing the concentration of boric acid from 10 to 100 mg L -1 did not greatly impair removal efficiency. A kinetic investigation revealed that the reaction followed a pseudo-second order rate model. The optimal conditions under which 99.2% of boron was removed from treated wastewater with 10 mg L -1 -B, leaving less than 0.1 mg L -1 -B in the electrolyte, were pH 8 and 1.25 mA cm -2 for 120 min. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Electric treatment for hydrophilic ink deinking.

    PubMed

    Du, Xiaotang; Hsieh, Jeffery S

    2017-09-01

    Hydrophilic inks have been widely used due to higher printing speed, competitive cost and being healthy non-organic solvents. However, they cause problems in both product quality and process runnability due to their hydrophilic surface wettability, strong negative surface charge and sub-micron size. Electric treatment was shown to be able to increase the ink sizes from 60 nm to 700 nm through electrocoagulation and electrophoresis. In addition, electric treatment assisted flotation could reduce effective residual ink concentration (ERIC) by 90 ppm, compared with only 20 ppm by traditional flotation. Furthermore, the effect of electric treatment alone on ink separation was investigated by two anode materials, graphite and stainless steel. Both of them could remove hydrophilic inks with less than 1% yield loss via electroflotation and electrophoresis. But graphite is a better material as the anode because graphite reduced ERIC by an additional 100 ppm. The yield loss of flotation following electric treatment was also lower by 17% if graphite was the anode material. The difference between the two electrode materials resulted from electrocoagulation and ink redeposition during electric treatment. An electric pretreatment-flotation-hyperwashing process was conducted to understand the deinking performance in conditions similar to a paper mill, and the ERIC was reduced from 950 ppm to less than 400 ppm.

  20. Controlled destruction and temperature distributions in biological tissues subjected to monoactive electrocoagulation.

    PubMed

    Erez, A; Shitzer, A

    1980-02-01

    An analysis of the temperature fields developed in a biological tissue undergoing a monoactive electrical coagulating process is presented, including thermal recovery following prolonged heating. The analysis is performed for the passage of alternating current and assumes a homogeneous and isotropic tissue model which is uniformly perfused by blood at arterial temperature. Solution for the one-dimensional spherical geometry is obtained by a Laplace transform and numerical integrations. Results obtained indicate the major role which blood perfusion plays in determining the effects of the coagulating process; tissue temperatures and depth of destruction are drastically reduced as blood perfusion increases. Metabolic heat generation rate is found to have negligible effects on tissue temperatures whereas electrode thermal inertia affects temperature levels appreciably. However, electrodes employed in practice would have a low thermal inertia which might be regarded as zero for all practical purposes. It is also found that the depth of tissue destruction is almost directly proportional to the electrical power and duration of application. To avoid excessively high temperatures and charring, it would be advantageous to reduce power and increase the time of application. Results of this study should be regarded as a first approximation to the rather complex phenomena associated with electrocoagulation. They may, nevertheless, serve as preliminary guidelines to practicing surgeons applying this technique.

  1. [Comparative analysis of application of highly intensive laser irradiation and electrocoagulation during laparoscopic cholecystectomy performed for destructive forms of an acute calculous cholecystitis].

    PubMed

    Nichitayio, M Yu; Bazyak, A M; Klochan, V V; Grusha, P K; Goman, A V

    2015-02-01

    Comparative analysis of results of the laser diode (the wave length 940 nm) and elec- trocoagulation application while performing laparoscopic cholecystectomy was con- ducted. For an acute calculous cholecystitis 52 patients were operated, in whom instead of electrocoagulation the laser was applied, provide for reduction of thermal impact on tissues, the complications absence, reduction of the patients stationary treatment duration postoperatively from (5.2 ± 1.2) to (4.9 ± 0.6) days.

  2. [Application of metal hemoclip for endoscopic polypectomy in children with thick-pedunculated intestinal polyps].

    PubMed

    Deng, Zhao-hui; Xu, Chun-di; Zhong, Jie; Chen, Shun-nian; Yao, Wei-jiong

    2004-03-01

    With the development of endoscopic therapy in children, endoscopic electrocoagulation polypectomy had gradually replaced surgery and became an important method to resect gastrointestinal polyps in children. Simple electrocoagulation polypectomy could often bring some complications of gastrointestinal bleeding and perforation because of incomplete electrocoagulation or mechanical incision, especially in gastrointestinal thick-pedunculated polyps which always have thick nutrient blood vessel. Hemoclips can successfully interdict arteriovenous blood because it can clamp tissue firmly without causing necrosis around the target area. Based on its good mechanical hemostasis, hemoclips are not only widely used in treating bleeding like from ulcer, tumor and variceal ligation but also used in removal of thick-pedunculated gastrointestinal polyps in adults. This paper describes the application of endoscopic electrocoagulation with metal hemoclips to remove thick-pedunculated intestinal polpys in children for the first time, sums up the experience and evaluates its efficacy and safety. Between October, 2001 and December, 2002, 5 cases with thick-pedunculated intestinal polpys were presented. The age of the patients ranged from 3 to 5 years. The clinical features were gastrointestinal bleeding or abdominal pain. The longest course of disease was 2 years. Enough preparations for alimentary tract were necessary for polypectomy. The procedures were performed under general anesthesia in order to avoid the risk of bleeding aspiration. Endoscopy was performed in the standard fashion. The apparatus included electronic colonic endoscope (XQ 200, Fuji Corp, Tokyo, Japan), snare (XQ200, Fuji Corp, Tokyo, Japan), impeller of the clip (HX-5QR-1) and hemoclip (MD850) which could be passed through the biopsy channel of endoscope. The clip was completely covered with a hood avoiding any injury to the mucous membrane. The pedicel with diameter of more than 1.0 cm underwent endoscopic electrocoagulation polypectomy with hemoclips. The clip contacted polyps in upright direction. One or more hemoclips were selected to clamp the proximal basement of the pedicel in terms of the pedicel diameter. Turning of the red colour of polyps to purple suggested that hemoclip interdicted arteriovenous blood effectively. The clip was then shut off and electrocoagulation polypectomy was followed. Six polyps were observed and removed. Six polyps including 2 transverse colon polyps and 4 descending colon polyps were resected. Pathological results showed that 3 were juvenile polyps and the other 3 adenomatous polyps. All the polyps were completely resected. The diameter of pedicel were 1.2 - 2.2 cm. The head and pedicel of the biggest polyp was about 5 cm x 5 cm and 2.2 cm, respectively, and five clips were used in order to remove it. No complications of bleeding and perforation were observed in these children. All hemoclips were expelled from intestines within one week. The symptoms of these patients disappeared. Mechanical hemostasis with hemoclips successfully interdicted arteriovenous blood of thick-pedunculated polyps. Hemoclips can successfully prevent the complications of bleeding and perforation. The clipping brings about a new method in endoscopic therapy. Endoscopic electrocoagulation polypectomy with hemoclips is a simple, safe and effective method to treat thick-pedunculated gastrointestinal polyps in children and it is a valuable tool in polypectomy for children.

  3. Electrocoagulation improving bone cement use in middle-ear surgery: short-term and middle-term results.

    PubMed

    Galy-Bernadoy, C; Akkari, M; Mondain, M; Uziel, A; Venail, F

    2016-12-01

    Bone cement is used for ossicular chain repair and revision stapes surgery. Its efficient use requires cautious removal of mucosa from the ossicles. This paper reports a technique for easy, fast and safe removal of this mucosa prior to cement application. It consists of the application of monopolar electrocoagulation on the ossicles prior to bone cement application. The outcomes of six cases of revision stapes surgery and seven cases of partial ossiculoplasty, conducted between 2007 and 2012 using this new technique, were evaluated. Intra-operative reports and audiometric data were collected. During the last assessment, reconstruction using bone cement resulted in mean post-operative air-bone gaps of 4.1 ± 6.5 dB in revision stapes surgery cases and 5.7 ± 5.5 dB in partial ossiculoplasty cases, reflecting a significant hearing improvement (p = 0.03). No complications were observed. Electrocoagulation allows the removal of mucosa from the ossicles in an easy, fast and safe manner, enabling the use of bone cement for ossicular chain reconstruction.

  4. Electrocoagulation for the treatment of textile wastewaters with Al or Fe electrodes: compared variations of COD levels, turbidity and absorbance.

    PubMed

    Zongo, Inoussa; Maiga, Amadou Hama; Wéthé, Joseph; Valentin, Gérard; Leclerc, Jean-Pierre; Paternotte, Gérard; Lapicque, Francois

    2009-09-30

    Electrocoagulation technique has been used for the treatment of two wastewaters issued by textile industry. Treatment was carried out in a discontinuous system provided with aluminium or iron electrodes, and with recirculation of the liquid. The efficiency of the technique was followed depending on the electrode material in terms of water treatment, current efficiency of the dissolution, cell voltage, energy consumption to reach the same COD or turbidity abatement: regardless of the quality of the phase separation in the flocculation section downstream of the electrocoagulation cell, the two metals were found to be of comparable efficiency. Besides COD and absorbance were shown to follow similar, regular variations along the treatment; experimental data could be interpreted by a simple model involving the overall equilibrium between the metal dissolved--in the form of hydroxides--and the polluting substance. Abatement of the waste turbidity was observed to obey another law, with a sharp reduction of turbidity after a preliminary phase, where accumulation of metal hydroxide has no effect on this variable.

  5. Cadmium analysis using field deployable nano-band electrode system and its removal using electrocoagulation

    NASA Astrophysics Data System (ADS)

    Guttula, Mallikarjuna Murthy

    Cadmium (Cd) is an extremely toxic metal commonly found in industrial workplaces. Major industrial releases of Cd stem from waste streams, leaching of landfills, and from a variety of operations that involve cadmium or zinc. Particularly, cadmium can be released to drinking water from the corrosion of some galvanized plumbing and water main pipe materials. The United State Environmental Protection Agency (USEPA) has set the Maximum Contaminant Level (MCL) for cadmium at 5 ppb. Long term exposure of cadmium above the MCL results in kidney, liver, bone and blood damage. An accurate and rapid measurement of cadmium in the field remains a technical challenge. In this work, a relatively new method of a Nano-Band Electrode system using anodic stripping voltammetry was optimized by changing deposition potential, electrolyte, and plating time. We efficiently used Electrocoagulation remove cadmium from wastewater and obtained a removal efficiency of +/-99%. Removal mechanism of cadmium in electrocoagulation was also proposed with the help of X-ray Diffraction (XRD), Attenuated Total Reflection - Fourier Transform Infra Red Spectroscopy (ATR-FTIR), and Scanning Electron Microscopy and Energy Dispersive Spectrometer (SEM-EDS).

  6. Optimization of Acid Black 172 decolorization by electrocoagulation using response surface methodology

    PubMed Central

    2012-01-01

    This paper utilizes a statistical approach, the response surface optimization methodology, to determine the optimum conditions for the Acid Black 172 dye removal efficiency from aqueous solution by electrocoagulation. The experimental parameters investigated were initial pH: 4–10; initial dye concentration: 0–600 mg/L; applied current: 0.5-3.5 A and reaction time: 3–15 min. These parameters were changed at five levels according to the central composite design to evaluate their effects on decolorization through analysis of variance. High R2 value of 94.48% shows a high correlation between the experimental and predicted values and expresses that the second-order regression model is acceptable for Acid Black 172 dye removal efficiency. It was also found that some interactions and squares influenced the electrocoagulation performance as well as the selected parameters. Optimum dye removal efficiency of 90.4% was observed experimentally at initial pH of 7, initial dye concentration of 300 mg/L, applied current of 2 A and reaction time of 9.16 min, which is close to model predicted (90%) result. PMID:23369574

  7. Deciphering the science behind electrocoagulation to remove suspended clay particles from water.

    PubMed

    Holt, P K; Barton, G W; Mitchell, C A

    2004-01-01

    Electrocoagulation removes pollutant material from water by a combination of coagulant delivered from a sacrificial aluminium anode and hydrogen bubbles evolved at an inert cathode. Rates of clay particle flotation and settling were experimentally determined in a 7 L batch reactor over a range of currents (0.25-2.0 A) and pollutant loadings (0.1-1.7 g/L). Sedimentation and flotation are the dominant removal mechanism at low and high currents, respectively. This shift in separation mode can be explained by analysing the reactor in terms of a published dissolved air flotation model.

  8. American cutaneous leishmaniasis triggered by electrocoagulation.

    PubMed

    Martins, Sofia Sales; Santos, Adriana de Oliveira; Lima, Beatriz Dolabela; Gomes, Ciro Martins; Sampaio, Raimunda Nonata Ribeiro

    2018-01-01

    Cutaneous leishmaniasis is usually transmitted by infected phlebotomine sand fly bites that initiate local cutaneous lesions. Few reports in the literature describe other modes of transmission. We report a case of a previously healthy 59-year-old woman who underwent electrocoagulation to remove seborrheic keratosis confirmed by dermatoscopy. Three months later, a skin fragment tested positive for Leishmania culture; the parasite was identified as L. (V.) braziliensis. Trauma may generate inflammatory cascades that favor Leishmania growth and lesion formation in previously infected patients. American cutaneous leishmaniasis is a dynamic disease with unclear pathophysiology because of continually changing environments, demographics, and human behaviors.

  9. Histology assessment of bipolar coagulation and argon plasma coagulation on digestive tract

    PubMed Central

    Garrido, Teresa; Baba, Elisa R; Wodak, Stephanie; Sakai, Paulo; Cecconello, Ivan; Maluf-Filho, Fauze

    2014-01-01

    AIM: To analyze the effect of bipolar electrocoagulation and argon plasma coagulation on fresh specimens of gastrointestinal tract. METHODS: An experimental evaluation was performed at Hospital das Clinicas of the University of São Paulo, on 31 fresh surgical specimens using argon plasma coagulation and bipolar electrocoagulation at different time intervals. The depth of tissue damage was histopathologically analyzed by single senior pathologist unaware of the coagulation method and power setting applied. To analyze the results, the mucosa was divided in superficial mucosa (epithelial layer of the esophagus and superficial portion of the glandular layer of the stomach and colon) intermediate mucosa (until the lamina propria of the esophagus and until the bottom of the glandular layer of the stomach and colon) and muscularis mucosa. Necrosis involvement of the layers was compared in several combinations of power and time interval. RESULTS: Involvement of the intermediate mucosa of the stomach and of the muscularis mucosa of the three organs was more frequent when higher amounts of energy were used with argon plasma. In the esophagus and in the colon, injury of the intermediate mucosa was frequent, even when small amounts of energy were used. The use of bipolar electrocoagulation resulted in more frequent involvement of the intermediate mucosa and of the muscularis mucosa of the esophagus and of the colon when higher amounts of energy were used. In the stomach, these involvements were rare. The risk of injury of the muscularis propria was significant only in the colon when argon plasma coagulation was employed. CONCLUSION: Tissue damage after argon plasma coagulation is deeper than bipolar electrocoagulation. Both of them depend on the amount of energy used. PMID:25031789

  10. Efficacy of electrocoagulation in sealing the cystic artery and cystic duct occluded with only one absorbable clip during laparoscopic cholecystectomy.

    PubMed

    Yang, Chang-Ping; Cao, Jin-Lin; Yang, Ren-Rong; Guo, Hong-Rong; Li, Zhao-Hui; Guo, Hai-Ying; Shao, Yin-Can; Liu, Gui-Bao

    2014-02-01

    Even though laparoscopic cholecystectomy (LC) emerged over 20 years ago, controversies persist with regard to the best method to ligate the cystic duct and artery. We proposed to assess the effectiveness and safety of electrocoagulation to seal the cystic artery and cystic duct after their occlusion with only one absorbable clip. We retrospectively compared the clinical data for 635 patients undergoing LC using electrocoagulation to seal the cystic artery and cystic duct that were occluded with only one absorbable clip (Group 1) and 728 patients undergoing LC using titanium clips (Group 2). In parallel, 30 rabbits randomized into six groups underwent cholecystectomy. After cystic duct ligation with absorbable or titanium clips, the animals were sacrificed 1, 3, or 6 months later, and intraabdominal adhesions were assessed after celiotomy. The mean operative time was significantly shorter (41.6 versus 58.9 minutes, P<.01) in Group 1 than in Group 2. No cystic duct leaks occurred in any patients from Group 1, compared with seven leaks among the 728 (0.96%) patients from Group 2 (P<.05). The morbidity was significantly higher in Group 2 than in Group 1 (3.43% versus 1.58%). Mean intraoperative blood loss and hospitalization length were not significantly different between the two groups, and no deaths occurred in either group. In animal experiments, adhesion was tighter for absorbable than for titanium clips, but fibrous tissue encapsulation was thinner at the site of titanium clips. Electrocoagulation of the cystic artery and cystic duct that were occluded with only one absorbable clip is safe and effective during LC. This approach is associated with shortened operative times and reduced leakage, compared with the standard method using metal clips.

  11. Pathological documentation of complete elimination of Barrett's metaplasia following endoscopic multipolar electrocoagulation therapy

    PubMed Central

    Fennerty, M; Corless, C; Sheppard, B; Faigel, D; Lieberman, D; Sampliner, R

    2001-01-01

    The previous paradigm that Barrett's is an irreversible premalignant lesion has recently been challenged by a proliferation of reports documenting elimination of Barrett's by a variety of endoscopic techniques. Whether Barrett's is entirely eliminated is unknown as endoscopic biopsy samples the surface of the epithelium only. Numerous reports document underlying specialised columnar epithelium in many of these trials. Until now there have been no reports of pathological examination of the entire oesophagus as a specimen. This case documents complete elimination of intestinal metaplasia from the oesophagus and supports the biological plausibility of these research techniques.


Keywords: Barrett's oesophagus; endoscopy; multipolar electrocoagulation PMID:11413122

  12. Continuous electrocoagulation of cheese whey wastewater: an application of Response Surface Methodology.

    PubMed

    Tezcan Un, Umran; Kandemir, Ayse; Erginel, Nihal; Ocal, S Eren

    2014-12-15

    In this study, treatment of cheese whey wastewater was performed using a uniquely-designed continuous electrocoagulation reactor, not previously encountered in the literature. An iron horizontal rotating screw type anode was used in the continuous mode. An empirical model, in terms of effective operational factors, such as current density (40, 50, 60 mA/cm(2)), pH (3, 5, 7) and retention time (20, 40, 60 min), was developed through Response Surface Methodology. An optimal region characterized by low values of Chemical Oxygen Demand (COD) was determined. As a result of experiments, a linear effect in the removal efficiency of COD was obtained for current density and retention time, while the initial pH of the wastewater was found to have a quadratic effect in the removal efficiency of COD. The best fit nonlinear mathematical model, with a coefficient of determination value (R(2)) of 85%, was defined. An initial COD concentration of 15.500 mg/L was reduced to 2112 mg/L with a removal efficiency of 86.4%. In conclusion, it can be said that electrocoagulation was successfully applied for the treatment of cheese whey wastewater. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Extratropical Cyclones Leading to Extreme Weather Events over Central and Eastern North America

    NASA Astrophysics Data System (ADS)

    Bentley, Alicia M.

    Cool-season extreme weather events (EWEs) occurring over central and eastern North America are typically associated with strong extratropical cyclones (ECs) that are governed by varying combinations of baroclinic, diabatic, and barotropic processes. This dissertation investigates the climatology, evolution, and predictability of ECs leading to EWEs over central and eastern North America, and provides a foundation on which to compare ECs leading to EWEs to ordinary ECs forming over and traversing the same regions. A climatology of ECs leading to EWEs over central and eastern North America during October-March 1979-2016 reveals that these ECs typically form 1) in the lee of the Rocky Mountains, 2) over the south central U.S., and 3) along the east coast of North America at latitudes equatorward of the typical genesis locations of ordinary ECs. ECs leading to EWEs included in the climatology form most frequently in November and March, when the seasonal alignment of baroclinic and convectively driven forcings occurs. Consistent with previous studies of North American ECs, the location and frequency of ECs leading to EWEs are partially determined by the states of the Pacific-North American pattern and the North Atlantic Oscillation. Metrics representing baroclinic, diabatic, and barotropic processes are formulated in this dissertation and are used to determine the combinations of baroclinic, diabatic, and barotropic processes associated with the formation and maintenance of ordinary ECs and ECs leading to EWEs. These metrics reveal that ECs leading to EWEs are associated with contributions from baroclinic, diabatic, and barotropic processes that are 1) similar to those associated with ordinary ECs at the time of formation (t0) and 2) considerably larger than those associated with ordinary ECs at the time of maximum intensity (tmax). Baroclinic processes typically contribute more than diabatic and barotropic processes throughout the evolution of ECs leading to EWEs. Diabatic processes typically contribute more during the intensification of ECs leading to EWEs than during their maintenance after tmax, whereas barotropic processes typically contribute more during the maintenance of ECs leading to EWEs after tmax than during their intensification. The relative contributions from baroclinic, diabatic, and barotropic processes during the evolution of ECs leading to EWEs are also shown to differ based on their genesis location. The 1.0° NOAA Global Ensemble Forecast System (GEFS) reforecast dataset is used in this dissertation to evaluate the forecast skill associated with ordinary ECs and ECs leading to EWEs at 0-192-h lead times. Ordinary ECs are consistently too slow and left of track in the GEFS, and are often too weak at longer lead times. ECs leading to EWEs are consistently too weak, fast, and right of track in the GEFS at longer lead times, and consistently too strong, slow, and left of track at shorter lead times. The positions of ordinary ECs are forecast with less skill and more spread than the positions of ECs leading to EWEs in the GEFS, whereas the intensities of ordinary ECs and ECs leading to EWEs are forecast with similar skill and spread. Locations over central and eastern North America where the positions and intensities of ordinary ECs and ECs leading to EWEs are frequently forecast with relatively low and high skill and spread in the GEFS are also identified.

  14. Evaluative Conditioning: The “How” Question

    PubMed Central

    Jones, Christopher R.; Olson, Michael A.; Fazio, Russell H.

    2011-01-01

    Evaluative conditioning (EC) refers to attitude formation or change toward an object due to that object's mere co-occurrence with another valenced object or objects. This chapter focuses on the “how” question, that is, the question of what cognitive processes intervene between mere co-occurrence and attitude formation or change. Though EC has typically been thought of as occurring through a single, albeit contentious, mechanism, we begin by pointing out that both the heterogeneity of EC methodologies and the abundance of inconsistent results suggest that multiple processes with different characteristics can produce EC. We describe how the earliest posited process of EC, Pavlovian conditioning or signal learning, is a valid mechanism of EC that appears to have operated in some experiments but is unlikely to have operated in others and also cannot account for various EC findings. We describe other mechanisms of EC, when they can be expected to occur, and what characteristics they have. We particularly focus our attention on a process model of EC we have recently introduced, the implicit misattribution model. Finally, we describe the implications of a multi-process view of EC, which we argue can help resolve theoretical controversies and further the application of EC as a practical intervention for influencing attitudes in various domains. PMID:22241936

  15. Gaining control: changing relations between executive control and processing speed and their relevance for mathematics achievement over course of the preschool period

    PubMed Central

    Clark, Caron A. C.; Nelson, Jennifer Mize; Garza, John; Sheffield, Tiffany D.; Wiebe, Sandra A.; Espy, Kimberly Andrews

    2014-01-01

    Early executive control (EC) predicts a range of academic outcomes and shows particularly strong associations with children's mathematics achievement. Nonetheless, a major challenge for EC research lies in distinguishing EC from related cognitive constructs that also are linked to achievement outcomes. Developmental cascade models suggest that children's information processing speed is a driving mechanism in cognitive development that supports gains in working memory, inhibitory control and associated cognitive abilities. Accordingly, individual differences in early executive task performance and their relation to mathematics may reflect, at least in part, underlying variation in children's processing speed. The aims of this study were to: (1) examine the degree of overlap between EC and processing speed at different preschool age points; and (2) determine whether EC uniquely predicts children's mathematics achievement after accounting for individual differences in processing speed. As part of a longitudinal, cohort-sequential study, 388 children (50% boys; 44% from low income households) completed the same battery of EC tasks at ages 3, 3.75, 4.5, and 5.25 years. Several of the tasks incorporated baseline speeded naming conditions with minimal EC demands. Multidimensional latent models were used to isolate the variance in executive task performance that did not overlap with baseline processing speed, covarying for child language proficiency. Models for separate age points showed that, while EC did not form a coherent latent factor independent of processing speed at age 3 years, it did emerge as a distinct factor by age 5.25. Although EC at age 3 showed no distinct relation with mathematics achievement independent of processing speed, EC at ages 3.75, 4.5, and 5.25 showed independent, prospective links with mathematics achievement. Findings suggest that EC and processing speed are tightly intertwined in early childhood. As EC becomes progressively decoupled from processing speed with age, it begins to take on unique, discriminative importance for children's mathematics achievement. PMID:24596563

  16. In vivo MRI assessment of permanent middle cerebral artery occlusion by electrocoagulation: pitfalls of procedure

    PubMed Central

    2010-01-01

    Permanent middle cerebral artery (MCA) occlusion (pMCAO) by electrocoagulation is a commonly used model but with potential traumatic lesions. Early MRI monitoring may assess pMCAO for non-specific brain damage. The surgical steps of pMCAO were evaluated for traumatic cerebral injury in 22 Swiss mice using diffusion and T2-weighted MRI (7T) performed within 1 h and 24 h after surgery. Temporal muscle cauterization without MCA occlusion produced an early T2 hyperintensity mimicking an infarct. No lesion was visible after temporal muscle incision or craniotomy. Early MRI monitoring is useful to identify non-specific brain injury that could hamper neuroprotective drugs assessment. PMID:20298536

  17. Treatment of wastewater batik by electrochemical coagulation using aluminium (Al) electrodes

    NASA Astrophysics Data System (ADS)

    Riyanto; Puspitasari, Eny

    2018-01-01

    Treatmentof wastewater batik by electrocoagulation method using aluminium (Al) electrodes has been done. Electrocoagulation method was chosen for treatment of wastewater batik because it is cheap, easy and efficient waste degradation. This research was conducted using aluminium (Al) electrodes and sodium chloride as an electrolyte solution. The purity of aluminium electrode was analysis using Scanning Electron Microscopy-Energy Dispersive X-ray (SEM-EDX). Electrochemical coagulation has been done using wastewater batik volume 50 mL with variation of time (10, 30, 50, 70, and 90 minutes), variation of voltage (5, 7, 9, 10, and 11 V), and variation of salt addition (0.5; 0.75; 1.00; and 1.25 g). Batik wastewater was analyzed before and after electrocoagulation by Spectrophotometer UV-Vis and the content of Pb was analyzed by Atomic Absorption Spectrophotometer (AAS). The research results show that optimum conditions electrolysis time, voltage and sodium chloride was 90 minutes, 10 V and 1.25 g, respectively. The results of this study showed the longer the electrolysis time, the higher the voltage, and the increasing number of salt added, then the batik waste decreased absorbance, alteration of color from black to clear yellow. The content of Pb in batik waste has decreased from 0.5844 mg/L to 0.1630 mg/L.

  18. Lidocaine/prilocaine cream (EMLA(R)) versus infiltration anaesthesia: a comparison of the analgesic efficacy for punch biopsy and electrocoagulation of genital warts in men.

    PubMed Central

    vd Berg, G M; Lillieborg, S; Stolz, E

    1992-01-01

    OBJECTIVES--To compare analgesic efficacy and pain caused by administration of lidocaine/prilocaine cream (EMLA(R)) versus xylocaine 1% local infiltration for punch biopsy and electrocoagulation of genital warts in men. DESIGN--Open randomised comparative parallel-group study. SETTING--Department of Dermatovenereology, University Hospital Rotterdam/Dijkzigt, the Netherlands. PATIENTS--63 males with warts on the genital mucosa and/or perianal area. METHODS--EMLA(R) cream (2.5-5 g) was applied during 13-45 minutes before surgery. Xylocaine 1% (0.1-4 ml) was infiltrated 0.5-4 minutes before surgery. Pain during administration and surgery was assessed by the patient on a verbal rating scale and on a visual analogue scale. RESULTS--EMLA(R) application was painless in all patients (n = 31) whereas xylocaine infiltration was slightly painful in 17/29 patients and moderately painful in 10/29 patients. EMLA(R) analgesia was satisfactory for 94% of biopsies and 62% of electrocoagulations. Xylocaine infiltration was satisfactory in all procedures. CONCLUSIONS--EMLA(R) application on the male genital mucosa is painless but it has a lower analgesic efficacy than xylocaine infiltration. However EMLA is a useful anaesthetic for taking biopsies in this area and may be used as premedication for local infiltration. PMID:1607191

  19. Laminar activity in the hippocampus and entorhinal cortex related to novelty and episodic encoding

    PubMed Central

    Maass, Anne; Schütze, Hartmut; Speck, Oliver; Yonelinas, Andrew; Tempelmann, Claus; Heinze, Hans-Jochen; Berron, David; Cardenas-Blanco, Arturo; Brodersen, Kay H.; Enno Stephan, Klaas; Düzel, Emrah

    2014-01-01

    The ability to form long-term memories for novel events depends on information processing within the hippocampus (HC) and entorhinal cortex (EC). The HC–EC circuitry shows a quantitative segregation of anatomical directionality into different neuronal layers. Whereas superficial EC layers mainly project to dentate gyrus (DG), CA3 and apical CA1 layers, HC output is primarily sent from pyramidal CA1 layers and subiculum to deep EC layers. Here we utilize this directionality information by measuring encoding activity within HC/EC subregions with 7 T high resolution functional magnetic resonance imaging (fMRI). Multivariate Bayes decoding within HC/EC subregions shows that processing of novel information most strongly engages the input structures (superficial EC and DG/CA2–3), whereas subsequent memory is more dependent on activation of output regions (deep EC and pyramidal CA1). This suggests that while novelty processing is strongly related to HC–EC input pathways, the memory fate of a novel stimulus depends more on HC–EC output. PMID:25424131

  20. Water Reclamation and Reuse.

    PubMed

    Huang, Chunkai; Zeng, Ping; Yang, Sen; Shao, Yanxi; Liu, Yang

    2016-10-01

    A review of the literature published in 2015 on topics relating to water reclamation and reuse is presented. The review is divided into the following sections: (1) General: extent of reuse, research needs, guidelines and monitoring, health effects; (2) Treatment technologies: integrated process design, membrane treatment, membrane bioreactors, electrocoagulation, ion exchange and adsorption, disinfection, wetlands, managed aquifer recharge; (3) Planning and management: public acceptance and education, economics/pricing, water quality planning and management and project/case studies. Much of the water treatment research focuses on membrane treatment, integrated designs, and other innovative technologies.

  1. Modeling of Electrochemical Process for the Treatment of Wastewater Containing Organic Pollutants

    NASA Astrophysics Data System (ADS)

    Rodrigo, Manuel A.; Cañizares, Pablo; Lobato, Justo; Sáez, Cristina

    Electrocoagulation and electrooxidation are promising electrochemical technologies that can be used to remove organic pollutants contained in wastewaters. To make these technologies competitive with the conventional technologies that are in use today, a better understanding of the processes involved must be achieved. In this context, the development of mathematical models that are consistent with the processes occurring in a physical system is a relevant advance, because such models can help to understand what is happening in the treatment process. In turn, a more detailed knowledge of the physical system can be obtained, and tools for a proper design of the processes, or for the analysis of operating problems, are attained. The modeling of these technologies can be carried out using single-variable or multivariable models. Likewise, the position dependence of the model species can be described with different approaches. In this work, a review of the basics of the modeling of these processes and a description of several representative models for electrochemical oxidation and coagulation are carried out. Regarding electrooxidation, two models are described: one which summarizes the pollution of a wastewater in only one model species and that considers a macroscopic approach to formulate the mass balances and other that considers more detailed profile of concentration to describe the time course of pollutants and intermediates through a mixed maximum gradient/macroscopic approach. On the topic of electrochemical coagulation, two different approaches are also described in this work: one that considers the hydrodynamic conditions as the main factor responsible for the electrochemical coagulation processes and the other that considers the chemical interaction of the reagents and the pollutants as the more significant processes in the description of the electrochemical coagulation of organic compounds. In addition, in this work it is also described a multivariable model for the electrodissolution of anodes (first stage in electrocoagulation processes). This later model use a mixed macroscopic/maximum gradient approach to describe the chemical and electrochemical processes and it also assumes that the rates of all processes are very high, and that they can be successfully modeled using pseudoequilibrium approaches.

  2. Treatment of heavy metal polluted industrial wastewater by a new water treatment process: ballasted electroflocculation.

    PubMed

    Brahmi, Khaled; Bouguerra, Wided; Harbi, Soumaya; Elaloui, Elimame; Loungou, Mouna; Hamrouni, Béchir

    2018-02-15

    This laboratory study investigated the parameters efficiency of the new technology: ballasted electro-flocculation (BEF) using aluminum (Al) electrodes to remove cadmium and zinc from industrial mining wastewater (MWW). The principle of the BEF process is based on the use of micro-sand and polymer together to increase the weight of the flocs and the rate at which they settle is radically changing the electrocoagulation-electroflocculation settling methodology. Based on the examination of the operation parameters one by one, the best removal percentage was obtained at a current intensity of 2A, a the flow rate of 20L/h, a micro-sand dose of 6g/L, a polyéthylèneimine (PEI) polymer dose of 100mg, the contact times of 30min, a stirring speed of 50 RPM, a monopolar configuration of the electrodes, and an electrodes number of 10. The results showed that the flow rate and the current density have a preponderant effect on the variability of the quality of the settled water. In comparison, filterability was found to be more sensitive to number of electrodes, micro sand dosages and current density. It was dependent on the ratio of microsand to PEI polymer dosage, and improved when this ratio increased. Response surface methodology was applied to evaluate the main effects and interactions among stirring speed, polymer dose, current intensity, and electrodes number. The removal of Cd and Zn from industrial MWW was done for very low cost of 0.1TND/m 3 equivalent to 0.04€/m 3 . The investigation of BEF process proposes a highly cost-effective wastewater treatment method if compared to Actiflo TM and electrocoagulation. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Postpolypectomy Electrocoagulation Syndrome: A Mimicker of Colonic Perforation

    PubMed Central

    Benson, Brian C.; Myers, Jonathan J.; Laczek, Jeffrey T.

    2013-01-01

    Postpolypectomy electrocoagulation syndrome is a rare complication of polypectomy with electrocautery and is characterized by a transmural burn of the colon wall. Patients typically present within 12 hours after the procedure with symptoms mimicking colonic perforation. Presented is the case of a 56-year-old man who developed abdominal pain six hours after colonoscopy during which polypectomy was performed using snare cautery. CT imaging of the abdomen revealed circumferential thickening of the wall of the transverse colon without evidence of free air. The patient was treated conservatively as an outpatient and had resolution of his pain over the following four days. Recognition of the diagnosis and understanding of the treatment are important to avoid unnecessary exploratory laparotomy or hospitalization. PMID:23956889

  4. Treatment of industrial effluents by a continuous system: electrocoagulation--activated sludge.

    PubMed

    Moisés, Tejocote-Pérez; Patricia, Balderas-Hernández; Barrera-Díaz, C E; Gabriela, Roa-Morales; Natividad-Rangel, Reyna

    2010-10-01

    A continuous system electrocoagulation--active sludge was designed and built for the treatment of industrial wastewater. The system included an electrochemical reactor with aluminum electrodes, a clarifier and a biological reactor. The electrochemical reactor was tested under different flowrates (50, 100 and 200 mL/min). In the biological reactor, the performance of different cultures of active sludge was assessed: coliform bacterial, ciliate and flagellate protozoa and aquatic fungus. Overall treatment efficiencies of color, turbidity and COD removal were 94%, 92% and 80%, respectively, under optimal conditions of 50 mL/min flowrate and using ciliate and flagellate protozoa. It was concluded that the system was efficient for the treatment of industrial wastewater. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. High Time- and Size-Resolved Measurements of PM and Chemical Composition from Coal Combustion: Implications for the EC Formation Process.

    PubMed

    Han, Yong; Chen, Yingjun; Ahmad, Saud; Feng, Yanli; Zhang, Fan; Song, Wenhuai; Cao, Fang; Zhang, Yanlin; Yang, Xin; Li, Jun; Zhang, Gan

    2018-06-05

    Inefficient coal combustion is a significant source of elemental carbon (EC) air pollution in China, but there is a limited understanding of EC's formation processes. In this study, high time-resolved particle number size distributions (PNSDs) and size-resolved chemical compositions were obtained from the combustion of four bituminous coals burned in a quartz tube furnace at 500 and 800 °C. Based on the distinct characteristics of PNSD, the flaming stage was divided into the first-flaming stage (with a PNSD peak at 0.3-0.4 μm) and the second-flaming stage (with a PNSD peak at 0.1-0.15 μm). For the size-segregated EC and OC measurements, more soot-EC was observed in particles larger than 0.3 μm, whereas the smaller ones possessed more char-EC. The results indicated that gas-phase and direct-conversion EC generation mechanisms dominate different burning stages. The analysis of 16 parent PAHs showed more high-molecular-weight PAHs in the second-flaming stage particles, which supports the idea of different formation processes for char-EC and soot-EC. For all four coals, the PNSD and chemical compositions shared a similar trend, confirming that the different formation processes of EC in different flaming stages were common. This study provides novel information concerning EC formation.

  6. Mechanisms of boron removal from hydraulic fracturing wastewater by aluminum electrocoagulation.

    PubMed

    Sari, Mutiara Ayu; Chellam, Shankararaman

    2015-11-15

    Boron uptake from highly saline hydraulic fracturing wastewater by freshly precipitated amorphous Al(OH)3 precipitates is due to ligand exchange and complexation with surface hydroxyl groups. Consequently, aluminum electrocoagulation can be a feasible approach to remove boron from flowback/produced water. Actual hydraulic fracturing wastewater containing ∼120mg/L boron from the Eagle Ford shale play was employed. Electrocoagulation was performed over a range of aluminum dosages (0-1350mg/L), pH 6.4 and 8, and high current densities (20-80mA/cm(2)) using a cylindrical aluminum anode encompassed by a porous cylindrical 316-stainless steel cathode. Direct measurements of boron uptake along with its chemical state and coordination were made using Attenuated Total Reflection-Fourier Transform Infrared spectroscopy (ATR-FTIR) and X-Ray Photoelectron Spectroscopy. Boron removal increased monotonically with aluminum dosage and was higher at pH 8, but remained relatively constant at ⩾20mA/cm(2). Chloride ions induced anodic pitting and super-Faradaic (131% efficiency) aluminum dissolution and their electrooxidation produced free chlorine. ATR-FTIR suggested outer-sphere and inner-sphere complexation of trigonal B(OH)3 with Al(OH)3, which was confirmed by the BO bond shifting toward lower binding energies in XPS. Severe AlO interferences precluded evidence for tetrahedral B(OH)4(-) complexation. No evidence for co-precipitation was obtained. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Plasmodium falciparum Adhesion on Human Brain Microvascular Endothelial Cells Involves Transmigration-Like Cup Formation and Induces Opening of Intercellular Junctions

    PubMed Central

    Jambou, Ronan; Combes, Valery; Jambou, Marie-Jose; Weksler, Babeth B.; Couraud, Pierre-Olivier; Grau, Georges E.

    2010-01-01

    Cerebral malaria, a major cause of death during malaria infection, is characterised by the sequestration of infected red blood cells (IRBC) in brain microvessels. Most of the molecules implicated in the adhesion of IRBC on endothelial cells (EC) are already described; however, the structure of the IRBC/EC junction and the impact of this adhesion on the EC are poorly understood. We analysed this interaction using human brain microvascular EC monolayers co-cultured with IRBC. Our study demonstrates the transfer of material from the IRBC to the brain EC plasma membrane in a trogocytosis-like process, followed by a TNF-enhanced IRBC engulfing process. Upon IRBC/EC binding, parasite antigens are transferred to early endosomes in the EC, in a cytoskeleton-dependent process. This is associated with the opening of the intercellular junctions. The transfer of IRBC antigens can thus transform EC into a target for the immune response and contribute to the profound EC alterations, including peri-vascular oedema, associated with cerebral malaria. PMID:20686652

  8. Molecular basis for endothelial lumen formation and tubulogenesis during vasculogenesis and angiogenic sprouting

    PubMed Central

    Davis, George E.; Stratman, Amber N.; Sacharidou, Anastasia; Koh, Wonshill

    2013-01-01

    Many studies reveal a fundamental role for extracellular matrix-mediated signaling through integrins and Rho GTPases as well as matrix metalloproteinases (MMPs) in the molecular control of vascular tube morphogenesis in three-dimensional (3D) tissue environments. Recent work has defined an EC lumen signaling complex of proteins that controls these vascular morphogenic events. These findings reveal a signaling interdependence between Cdc42 and MT1-MMP to control the 3D matrix-specific process of EC tubulogenesis. The EC tube formation process results in the creation of a network of proteolytically-generated vascular guidance tunnels in 3D matrices that are utilized to remodel EC-lined tubes through EC motility and could facilitate processes such as flow-induced remodeling and arteriovenous EC sorting and differentiation. Within vascular guidance tunnels, key dynamic interactions occur between endothelial cells (ECs) and pericytes to affect vessel remodeling, diameter, and vascular basement membrane matrix assembly, a fundamental process necessary for endothelial tube maturation and stabilization. Thus, the EC lumen and tube formation mechanism coordinates the concomitant establishment of a network of vascular tubes within tunnel spaces to allow for flow responsiveness, EC-mural cell interactions, and vascular extracellular matrix assembly to control the development of the functional microcirculation. PMID:21482411

  9. Is evaluative conditioning really uncontrollable? A comparative test of three emotion-focused strategies to prevent the acquisition of conditioned preferences.

    PubMed

    Gawronski, Bertram; Mitchell, Derek G V; Balas, Robert

    2015-10-01

    Evaluative conditioning (EC) is defined as the change in the evaluation of a conditioned stimulus (CS) because of its pairing with a valenced unconditioned stimulus (US). Counter to views that EC is the product of automatic learning processes, recent research has revealed various characteristics of nonautomatic processing in EC. The current research investigated the controllability of EC by testing the effectiveness of 3 emotion-focused strategies in preventing the acquisition of conditioned preferences: (a) suppression of emotional reactions to the US, (b) reappraisal of the valence of the US, and (c) facial blocking of emotional responses. Although all 3 strategies reduced EC effects on self-reported evaluations by impairing recollective memory for CS-US pairings, they were ineffective in reducing EC effects on an evaluative priming measure. Regardless of the measure, effective control did not depend on the level of arousal elicited by the US. The results suggest that the 3 strategies can influence deliberate CS evaluations through memory-related processes, but they are ineffective in reducing EC effects on spontaneous evaluative responses. Implications for mental process theories of EC are discussed. (c) 2015 APA, all rights reserved).

  10. Simultaneous removal of oil and grease, and heavy metals from artificial bilge water using electro-coagulation/flotation.

    PubMed

    Rincón, Guillermo J; La Motta, Enrique J

    2014-11-01

    US and international regulations pertaining to the control of bilge water discharges from ships have concentrated their attention to the levels of oil and grease rather than to the heavy metal concentrations. The consensus is that any discharge of bilge water (and oily water emulsion within 12 nautical miles from the nearest land cannot exceed 15 parts per million (ppm). Since there is no specific regulation for metal pollutants under the bilge water section, reference standards regulating heavy metal concentrations are taken from the ambient water quality criteria to protect aquatic life. The research herein presented discusses electro-coagulation (EC) as a method to treat bilge water, with a focus on oily emulsions and heavy metals (copper, nickel and zinc) removal efficiency. Experiments were run using a continuous flow reactor, manufactured by Ecolotron, Inc., and a synthetic emulsion as artificial bilge water. The synthetic emulsion contained 5000 mg/L of oil and grease, 5 mg/L of copper, 1.5 mg/L of nickel, and 2.5 mg/l of zinc. The experimental results demonstrate that EC is very efficient in removing oil and grease. For oil and grease removal, the best treatment and cost efficiency was obtained when using a combination of carbon steel and aluminum electrodes, at a detention time less than one minute, a flow rate of 1 L/min and 0.6 A/cm(2) of current density. The final effluent oil and grease concentration, before filtration, was always less than 10 mg/L. For heavy metal removal, the combination of aluminum and carbon steel electrodes, flow rate of 1 L/min, effluent recycling, and 7.5 amps produced 99% zinc removal efficiency. Copper and nickel are harder to remove, and a removal efficiency of 70% was achieved. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Subliminal influence on preferences? A test of evaluative conditioning for brief visual conditioned stimuli using auditory unconditioned stimuli

    PubMed Central

    2017-01-01

    In the field of evaluative conditioning (EC), two opposing theories—propositional single-process theory versus dual-process theory—are currently being discussed in the literature. The present set of experiments test a crucial prediction to adjudicate between these two theories: Dual-process theory postulates that evaluative conditioning can occur without awareness of the contingency between conditioned stimulus (CS) and unconditioned stimulus (US); in contrast, single-process propositional theory postulates that EC requires CS-US contingency awareness. In a set of three studies, we experimentally manipulate contingency awareness by presenting the CSs very briefly, thereby rendering it unlikely to be processed consciously. We address potential issues with previous studies on EC with subliminal or near-threshold CSs that limited their interpretation. Across two experiments, we consistently found an EC effect for CSs presented for 1000 ms and consistently failed to find an EC effect for briefly presented CSs. In a third pre-registered experiment, we again found evidence for an EC effect with CSs presented for 1000 ms, and we found some indication for an EC effect for CSs presented for 20 ms. PMID:28989730

  12. Subliminal influence on preferences? A test of evaluative conditioning for brief visual conditioned stimuli using auditory unconditioned stimuli.

    PubMed

    Heycke, Tobias; Aust, Frederik; Stahl, Christoph

    2017-09-01

    In the field of evaluative conditioning (EC), two opposing theories-propositional single-process theory versus dual-process theory-are currently being discussed in the literature. The present set of experiments test a crucial prediction to adjudicate between these two theories: Dual-process theory postulates that evaluative conditioning can occur without awareness of the contingency between conditioned stimulus (CS) and unconditioned stimulus (US); in contrast, single-process propositional theory postulates that EC requires CS-US contingency awareness. In a set of three studies, we experimentally manipulate contingency awareness by presenting the CSs very briefly, thereby rendering it unlikely to be processed consciously. We address potential issues with previous studies on EC with subliminal or near-threshold CSs that limited their interpretation. Across two experiments, we consistently found an EC effect for CSs presented for 1000 ms and consistently failed to find an EC effect for briefly presented CSs. In a third pre-registered experiment, we again found evidence for an EC effect with CSs presented for 1000 ms, and we found some indication for an EC effect for CSs presented for 20 ms.

  13. Identification of the IGF-1 processing product human Ec/rodent Eb peptide in various tissues: Evidence for its differential regulation after exercise-induced muscle damage in humans.

    PubMed

    Vassilakos, George; Philippou, Anastassios; Koutsilieris, Michael

    2017-02-01

    Insulin-like growth factor-1 (IGF-1) is a pleiotropic factor expressed in various tissues and plays a critical role in skeletal muscle physiology. Alternative splicing of the IGF-1 gene gives rise to different precursor polypeptides (isoforms) which could undergo post-translational cleavage, generating the common mature IGF-1 peptide and different carboxyl terminal extension (E-) peptides, with the fate of the latter being, so far, unknown. The objective if this study was to identify the IGF-1Ec forms or processing product(s), other than mature IGF-1, generated in different human and rodent tissues and particularly in human skeletal muscle after exercise-induced damage. Protein lysates from a wide range of human and rodent tissues were immunoblotted with a rabbit anti-human Ec polyclonal antibody raised against the last 24 amino acids of the C-terminal of the Ec peptide. This antibody can recognize the Ec peptide, both as part of IGF-1Ec and alone, and also the corresponding rodent forms, due to the high homology that the human Ec shares with the rodent Eb. We were able to confirm, for the first time, that the human Ec peptide and its rodent homologous Eb peptide are produced simultaneously with their precursor protein (pro-IGF-1Ec/Eb) in vivo, in a wide range of tissues (e.g. muscle, liver, heart). Proprotein convertase furin digestion of human muscle and liver protein lysates confirmed that the higher molecular form, pro-IGF-1Ec, can be cleaved to produce the free Ec peptide. Furthermore, initial evidence is provided that Ec peptide is differentially regulated during the process of muscle regeneration after exercise-induced damage in humans. The findings of this study possibly imply that the post-translational modification of the IGF-1Ec pro-peptide may regulate the bioavailability and activity of the processing product(s). Copyright © 2016. Published by Elsevier Ltd.

  14. Ovarian cryopreservation after laparoscopic ovariectomy using the Endo-GIA stapling device and LAPRO-clip absorbable ligating clip in a woman: a case report

    PubMed Central

    2011-01-01

    Introduction Several options are available for preserving fertility before cytotoxic treatment, including ovarian tissue cryopreservation. Most reported surgical techniques include electrocoagulation. Our hypothesis is that avoidance of electrocoagulation may decrease ovarian cortex injury during cryopreservation procedures. Case presentation We report a laparoscopic technique of whole-ovary removal without coagulation using Endo-GIA forceps and clips. Laparoscopic ovariectomy was performed for cryopreservation in a 37-year-old Caucasian woman with breast cancer and for whom chemotherapy was planned. The procedure was completed quickly and without complication. This Endo-GIA procedure was of short duration with a short period of ischemia before freezing. Conclusion Laparoscopic ovariectomy using the Endo-GIA stapling device procedure without coagulation may diminish ovary injury before ovarian cryopreservation. PMID:21291518

  15. Origin of Parietal Podocytes in Atubular Glomeruli Mapped by Lineage Tracing

    PubMed Central

    Schulte, Kevin; Berger, Katja; Boor, Peter; Jirak, Peggy; Gelman, Irwin H.; Arkill, Kenton P.; Neal, Christopher R.; Kriz, Wilhelm; Floege, Jürgen; Smeets, Bart

    2014-01-01

    Parietal podocytes are fully differentiated podocytes lining Bowman’s capsule where normally only parietal epithelial cells (PECs) are found. Parietal podocytes form throughout life and are regularly observed in human biopsies, particularly in atubular glomeruli of diseased kidneys; however, the origin of parietal podocytes is unresolved. To assess the capacity of PECs to transdifferentiate into parietal podocytes, we developed and characterized a novel method for creating atubular glomeruli by electrocoagulation of the renal cortex in mice. Electrocoagulation produced multiple atubular glomeruli containing PECs as well as parietal podocytes that projected from the vascular pole and lined Bowman’s capsule. Notably, induction of cell death was evident in some PECs. In contrast, Bowman’s capsules of control animals and normal glomeruli of electrocoagulated kidneys rarely contained podocytes. PECs and podocytes were traced by inducible and irreversible genetic tagging using triple transgenic mice (PEC- or Pod-rtTA/LC1/R26R). Examination of serial cryosections indicated that visceral podocytes migrated onto Bowman’s capsule via the vascular stalk; direct transdifferentiation from PECs to podocytes was not observed. Similar results were obtained in a unilateral ureter obstruction model and in human diseased kidney biopsies, in which overlap of PEC- or podocyte-specific antibody staining indicative of gradual differentiation did not occur. These results suggest that induction of atubular glomeruli leads to ablation of PECs and subsequent migration of visceral podocytes onto Bowman’s capsule, rather than transdifferentiation from PECs to parietal podocytes. PMID:24071005

  16. Electrocoagulative Surgical Procedure for Treatment of Conjunctivochalasis

    PubMed Central

    Zhang, Xing-Ru; Zhang, Zhen-Yong; Hoffman, Matthew R.

    2012-01-01

    The purpose of this study was to present a new procedure to treat symptomatic conjunctivochalasis (CCh) and to evaluate its efficacy. Forty-two patients with symptomatic CCh refractory to medical management were included on this study. Twenty-two patients (n  =  32, eyes; n  =  14 women and n  =  8 men) underwent the new electrocoagulation procedure (Group I). Twenty patients (n  =  27 eyes; n  =  11 women and n  =  9 men) underwent crescent-shaped conjunctiva resection (Group II). Ocular Surface Disease Index (OSDI) was used to evaluate ocular symptoms. There was a significant difference in mean and SD operation time between Group I (8.67 ± 2.07 minutes) and Group II (20.45 ± 3.98 minutes; P < 0.0001). OSDI scores (mean ± SD) were significantly lower in Group I (28.38 ± 3.14) than Group II (31.62 ± 3.17) at postoperative week 2 (P  =  0.0004). No differences in OSDI scores were found between the 2 groups at postoperative week 4 (P  =  0.1749) or 8 (P  =  0.1483). OSDI scores were significantly lower at postoperative week 8 than at baseline in both Group I (P  =  0.0002) and Group II (P  =  0.0011). Electrocoagulation of the conjunctiva can successfully treat symptomatic CCh with earlier symptomatic attenuation and less operation time than traditional conjunctiva resection. PMID:23102005

  17. Simultaneous removal of arsenite and fluoride via an integrated electro-oxidation and electrocoagulation process.

    PubMed

    Zhao, Xu; Zhang, Baofeng; Liu, Huijuan; Qu, Jiuhui

    2011-04-01

    An integrated electro-oxidation and electrocoagulation system was designed and used to remove As(III) and F(-) ions from water simultaneously. Dimensionally stable anodes (DSA), Fe electrodes, and Al electrodes were combined into an electrochemical system. Two pieces of DSA electrodes were assigned as the outside of the Fe and Al electrodes and were directly connected to the power supply as anode and cathode, respectively. The Fe and Al ions were generated by electro-induced process simultaneously. Subsequently, hydroxides of Fe and Al were formed. Arsenic ions are mainly removed by iron hydroxides and F(-) ions are mainly removed by the Al oxides. At the initial concentration of 1.0 mg L(-1), most of As(III) was transferred into As(V) within 40 min at current density of 4 mA cm(-2), whereas F(-) ions can be efficiently removed simultaneously. The effect of the ratio of Fe and Al plate electrodes and current density on the removal of As(III) and F(-) was investigated. With one piece of Fe plate electrode and three pieces of Al plate electrodes, it is observed that As(III) with concentration of 1 mg L(-1) and F(-) with concentration of 4.5 mg L(-1) can be removed and their final concentrations were below the values of 10 μg L(-1) and 1.0 mg L(-1), respectively within 40 min. Removal efficiency of As(III) increases with the increase of solution pH. However, in the pH range of 6-7, removal efficiency of F(-) is the largest. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Budget analysis of Escherichia coli at a southern Lake Michigan Beach

    USGS Publications Warehouse

    Thupaki, P.; Phanikumar, M.S.; Beletsky, D.; Schwab, D.J.; Nevers, M.B.; Whitman, R.L.

    2010-01-01

    Escherichia coli (EC) concentrations at two beaches impacted by river plume dynamics in southern Lake Michigan were analyzed using three-dimensional hydrodynamic and transport models. The relative importance of various physical and biological processes influencing the fate and transport of EC were examined via budget analysis and a first-order sensitivity analysis of model parameters. The along-shore advective fluxofEC(CFU/m2·s)was found to be higher compared to its crossshore counterpart; however, the sum of diffusive and advective components was of a comparable magnitude in both directions showing the importance of cross-shore exchange in EC transport. Examination of individual terms in the EC mass balance equation showed that vertical turbulent mixing in the water column dominated the overall EC transport for the summer conditions simulated. Dilution due to advection and diffusion accounted for a large portion of the total EC budget in the nearshore, and the net EC loss rate within the water column (CFU/m3·s) was an order of magnitude smaller compared to the horizontal and vertical transport rates. This result has important implications for modeling EC at recreational beaches; however, the assessment of the magnitude of EC loss rate is complicated due to the strong coupling between vertical exchange and depth-dependent EC loss processes such as sunlight inactivation and settling. Sensitivity analysis indicated that solar inactivation has the greatest impact on EC loss rates. Although these results are site-specific, they clearly bring out the relative importance of various processes involved.

  19. Posterior epistaxis: Common bleeding sites and prophylactic electrocoagulation.

    PubMed

    Liu, Juan; Sun, Xicai; Guo, Limin; Wang, Dehui

    2016-01-01

    Posterior epistaxis is a frequent emergency, and the key to efficient management is identification of the bleeding point. We performed a retrospective study of 318 patients with posterior epistaxis treated with endoscopic bipolar electrocautery during a 4-year period. Distribution of the bleeding sites was recorded. Patients with no definite bleeding sites in the first operation were assigned to Group A (n = 39) and Group B (n = 34). Patients in Group A were only observed in the ward. Patients in Group B were given prophylactic electrocoagulation at the common bleeding points. Of the 318 patients, bleeding sites were successfully identified and coagulated in 263 patients. All of them were located posteriorly, with 166 on the lateral nasal wall, 86 on the septum, and 11 on the anterior face of the sphenoid sinus. The rebleeding rate of Group B (8.8%) was lower than that of Group A (38.5%) (p < 0.01).

  20. Controlled and implicit processes in evaluative conditioning on implicit and explicit attitudes toward alcohol and intentions to drink.

    PubMed

    Zerhouni, Oulmann; Bègue, Laurent; Comiran, Francisco; Wiers, Reinout W

    2018-01-01

    Since implicit attitudes (i.e. evaluations occurring outside of complete awareness) are highly predictive of alcohol consumption, we tested an evaluative learning procedure based on repeated pairing to a critical stimulus (i.e. alcohol, the CS) with a valenced stimulus (the US) in order to modify implicit attitudes (i.e. evaluative conditioning; EC). We hypothesized that manipulating the learning context to bolster implicit affect misattribution should strengthen EC effects on implicit attitudes toward alcohol, while encouraging deliberate processing of CS-US pairs, should strengthen EC effects on explicit attitudes. In our study (n=114 students) we manipulated whether CS-US pairs were presented simultaneously or sequentially. Recollective memory was estimated with a Process Dissociation Procedure. Both implicit and explicit attitudes were assessed immediately after the procedure. Behavioral intentions were measured directly after and one week after the EC-procedure. We found that EC with sequential presentation had a stronger impact on implicit and explicit measures and on purchase intentions immediately after the procedure and one week after. The present findings provide new evidence that (i) EC is an effective way to change implicit attitudes toward alcohol and (ii) evidence that EC may be better described by propositional rather than dual process accounts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Analysis of the release process of phenylpropanolamine hydrochloride from ethylcellulose matrix granules.

    PubMed

    Fukui, Atsuko; Fujii, Ryuta; Yonezawa, Yorinobu; Sunada, Hisakazu

    2002-11-01

    The release properties of phenylpropanolamine hydrochloride (PPA) from ethylcellulose (EC, ethylcellulose 10 cps (EC#10) and/or 100 cps (EC#100)) matrix granules prepared by the extrusion granulation method were examined. The release process could be divided into two parts, and was well analyzed by applying square-root time law and cube root law equations, respectively. The validity of the treatments was confirmed by the fitness of the simulation curve with the measured curve. At the initial stage, PPA was released from the gel layer of swollen EC in the matrix granules. At the second stage, the drug existing below the gel layer dissolved, and was released through the gel layer. Also, the time and release ratio at the connection point of the simulation curves was examined to determine the validity of the analysis. Comparing the release properties of PPA from the two types of EC matrix granules, EC#100 showed more effective sustained release than EC#10. On the other hand, changes in the release property of the EC#10 matrix granule were relatively more clear than that of the EC#100 matrix granule. Thus, it was supposed that EC#10 is more available for controlled and sustained release formulations than EC#100.

  2. Risk Factors of Post-Endoscopic Submucosal Dissection Electrocoagulation Syndrome for Colorectal Neoplasm.

    PubMed

    Ito, Sayo; Hotta, Kinichi; Imai, Kenichiro; Yamaguchi, Yuichiro; Kishida, Yoshihiro; Takizawa, Kohei; Kakushima, Naomi; Tanaka, Masaki; Kawata, Noboru; Yoshida, Masao; Ishiwatari, Hirotoshi; Matsubayashi, Hiroyuki; Ono, Hiroyuki

    2018-06-04

    Colorectal endoscopic submucosal dissection (ESD) is used for the treatment of large colorectal superficial neoplasms. However, there have been no large studies on electrocoagulation syndrome developing after colorectal ESD. The aim of this study was to clarify the incidence and clinical risk factors of post-ESD electrocoagulation syndrome (PECS). A total of 692 patients (median age, 70 years; 395 men) with 692 lesions, who underwent colorectal ESD at a tertiary cancer center between July 2010 and December 2015 were eligible. PECS was clinically diagnosed based on the presence of localized abdominal tenderness matching the ESD enforcement site, and fever (>37.5°C) or an inflammatory response (C-reactive protein level >0.5 mg/dL or leukocytosis >10000 cells/μL), without obvious findings of perforation, which developed at >6 h post-ESD. Outcomes of the procedure, the incidence of PECS, and risk factors associated with PECS were assessed. The incidence of PECS was 4.8% (33 patients), and all patients improved by conservative treatment. On multivariate analysis, the female sex (odds ratio [OR] 2.6; 95% confidence interval [95% CI], 1.2-5.7), tumor location at the cecum (OR 14.5; 95% CI: 3.7-53.7 vs rectum), and the presence of submucosal fibrosis (OR 2.8; 95% CI: 1.1-7.5) were found to be independent risk factors of PECS. This study identified the risk factors for PECS. Patients with high risk factors of PECS require careful management after colorectal ESD. This article is protected by copyright. All rights reserved.

  3. [Comparison of hot versus cold biopsy forceps in the diagnosis of endobronchial lesions].

    PubMed

    Firoozbakhsh, Shahram; Seifirad, Soroush; Safavi, Enayat; Dinparast, Reza; Taslimi, Shervin; Derakhshandeilami, Gholamreza

    2011-11-01

    Traditionally cold biopsy forceps were used for endobronchial biopsy, and recently electrocautery (hot) bronchoscopy biopsy forceps are introduced. It is hypothesized that hot biopsy forceps may decrease procedure related bleeding and also may decrease the quality of obtained samples. Patients with different indications for endobronchial biopsy during fiberoptic bronchoscopy underwent three hot and three cold biopsies with a random fashion. All biopsies were obtained with a single biopsy forceps with and without the application of an electrocoagulation current, set on soft coagulation mode (40W). A four point scale was used for quantification of bleeding. A single pathologist blinded to the patients' history was requested to review all samples. A three point scale was used to assess electrocoagulation damage. A total of 240 biopsies were obtained from 40 patients. Frequency of positive concordance between the two methods was 85%. The degree of electrocoagulation damage of the samples was as follows: grade 1=52.5%, grade 2=32.5%, and grade 3=15%. The average bleeding score following hot biopsy was significantly lower compared to the cold biopsy (P=.006). The concordance between diagnostic yield of hot and cold biopsies was 85%. There was no significant difference between the diagnostic yields of two biopsy methods (P=.687). Hot biopsy forceps significantly decreased the procedure related bleeding. The quality of samples was not impaired significantly. Regarding low prevalence of bleeding following endobronchial biopsy, routine use of hot bronchoscopy forceps is not reasonable. However, familiarity of bronchoscopists with this method may improve bronchoscopy safety. Copyright © 2011 SEPAR. Published by Elsevier Espana. All rights reserved.

  4. Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?

    PubMed

    Campagnolo, Marcelo Ivo; Reis, Ricardo Dos; Santos, Marcele Oliveira Dos; Kliemann, Lúcia Maria; Savaris, Ricardo Francalacci

    2018-05-29

     To determine which mode and potency of electrocoagulation, using a modern electrosurgical generator, yields the smallest unobstructed area of the Fallopian tubes.  In an experimental study, tubes from 48 hysterectomies or tubal ligation were evaluated. Tubes were randomly allocated to one of the following groups: group A) 25 W x 5 seconds ( n  = 17); group B) 30 W x 5 seconds ( n  = 17); group C) 35 W x 5 seconds ( n  = 18), group D) 40 W x 5 seconds ( n  = 20); group E) 40 W x 5 seconds with visual inspection (blanch, swells, collapse) ( n  = 16); group F) 50 W x 5 seconds ( n  = 8). Bipolar electrocoagulation was performed in groups A to E, and monopolar electrocoagulation was performed in group F. Coagulation mode was used in all groups. Digital photomicrography of the transversal histological sections of the isthmic segment of the Fallopian tube were taken, and the median percentage of unobstructed luminal area (mm 2 ) was measured with ImageJ software (ImageJ, National Institutes of Health, Bethesda, MD, USA). The Kruskal-Wallis test or analysis of variance (ANOVA) was used for statistical analysis.  Ninety-six Fallopian tube sections were analyzed. The smallest median occluded area (%; range) of the Fallopian tube was obtained in the group with 40 W with visual inspection (8.3%; 0.9-40%), followed by the groups 25 W (9.1%; 0-35.9%), 40 W (14.2; 0.9-43.2%), 30 W (14.2; 0.9-49.7%), 35 W (15.1; 3-46.4%) and 50 W (38.2; 3.1-51%). No statistically significant difference was found among groups ( p  = 0.09, Kruskal-Wallis test).  The smallest unobstructed area was obtained with power setting at 40 W with visual inspection using a modern electrosurgical generator. However, no statistically significant difference in the unobstructed area was observed among the groups using these different modes and potencies. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  5. Decolourization of dye-containing effluent using mineral coagulants produced by electrocoagulation.

    PubMed

    Zidane, Fatiha; Drogui, Patrick; Lekhlif, Brahim; Bensaid, Jalila; Blais, Jean-François; Belcadi, Said; El Kacemi, Kacem

    2008-06-30

    The colour and colour causing-compounds has always been undesirable in water for any use, be it industrial or domestic wastewaters. The discharge of such effluents causes excessive oxygen demand in the receiving water and then a treatment is required before discharge into ecosystems. This study examined the possibility to remove colour causing-compounds from effluent by chemical coagulation, in comparison with direct electrocoagulation. The inorganic coagulants (C1, C2 and C3) in the form of dry powder tested, were respectively produced from electrolysis of S1=[NaOH (7.5 x 10(-3)M)], S2=[NaCl (10(-2)M)], and S3=[NaOH (7.5 x 10(-3)M)+NaCl (10(-2)M)] solutions, using sacrificial aluminium electrodes operated at an electrical potential of 12 V. Reactive textile dye (CI Reactive Red 141) was used as model of colour-causing compound prepared at a concentration of 50 mgl(-1). The best performances of dye removal were obtained with C(2) having a chemical structure comprised of a mixture of polymeric specie (Al45O45(OH)45Cl) and monomeric species (AlCl(OH)2.2H2O and Al(OH)3). The removal efficiency (R(A)) evaluated by measuring the yields of 540 nm-absorbance removal varied from 41 to 96% through 60 min of treatment by imposing a concentration of C2 ranging from 100 to 400 mg l(-1). The effectiveness of the treatment increased and the effluent became more and more transparent while increasing C(2) concentration. The comparison of chemical treatment using C2 coagulant and direct electrocoagulation of CI Reactive Red 141 containing synthetic solution demonstrated the advantage of chemical treatment during the first few minutes of treatment. A yield of 88% of absorbance removal was recorded using C2 coagulant (400 mg l(-1)) over the first 10 min of treatment, compared to 60% measured using direct electrocoagulation while imposing either 10 or 15 V of electrical potential close to the value (12 V) required during C2 production. However, at the end of the treatment (after 60 min of treatment), CI Reactive Red 141 pollutant was completely removed from solution (540 nm-absorbance removal of 100%) using direct electrochemical treatment, compared to 96.4% of absorbance removed while treating dye-containing synthetic solution by means of C2 coagulant.

  6. Vertebral growth modulation by hemicircumferential electrocoagulation: an experimental study in pigs.

    PubMed

    Caballero, Alberto; Barrios, Carlos; Burgos, Jesús; Hevia, Eduardo; Correa, Carlos

    2011-08-01

    This experimental study in pigs was aimed at evaluating spinal growth disorders after partial arrest of the vertebral epiphyseal plates (EP) and neurocentral cartilages (NCC). Unilateral and multisegmental single or combined lesions of the physeal structures were performed by electrocoagulation throughout a video-assisted thoracoscopical approach. Thirty 4-week-old domestic pigs (mean weight 16 kg) were included in the experiments. The superior and inferior epiphyseal plates of T5 to T9 vertebra were damaged in ten animals by hemicircumferential electrocoagulation (group I). In other ten pigs (group II), right NCC at the same T5-T9 levels were damaged. Ten other animals underwent combined lesions of the ipsilateral hemiepiphyseal plates and NCC at the T5-T9 levels. A total of 26 animals could be evaluated after 12 weeks of follow-up using conventional X-rays, CT scans and histology. The pigs with hemicircumferential EP damage developed very slight concave non-structured scoliotic deformities without vertebral rotation.(mean 12° Cobb; range10-16°). Some of the damaged vertebra showed a marked wedgening with unilateral development alteration of the vertebral body, including the adjacent discs The animals with damage of the NCC developed mild scoliotic curves (mean 19° Cobb; range 16-24°) with convexity opposite to the damaged side and loss of physiological kyphosis. The injured segments showed an asymmetric growth with hypoplasia of the pedicle and costovertebral joints at the damaged side. The pigs undergoing combined EP and NCC lesions developed minimal non-structured curves, ranging from 10 to 12° Cobb. In these animals there was a lack of growth of a vertebral hemibody and disc hypoplasia at the damaged segments. Both damage of the NCC and the EP affect the height of the vertebral body. No spinal stenosis was found in any case. In most cases, the adjacent superior and inferior vertebral EP to damaged segments had a compensatory growth that maintained the straight spinal shape. In summary, unilateral direct lesion of the EP by hemicircumferential thoracoscopic electrocoagulation modifies vertebral growth, but is not able to induce true scoliostic curves in pigs. Only animals with damaged NCC developed mild scoliotic curves of lordotic type. This work rediscovers and emphasizes the decisive role of the neurocentral cartilage in the ethiopatogeny of idiopathic scoliosis.

  7. [Preparation of ibuprofen/EC-PVP sustained-release composite particles by supercritical CO2 anti-solvent technology].

    PubMed

    Cai, Jin-Yuan; Huang, De-Chun; Wang, Zhi-Xiang; Dang, Bei-Lei; Wang, Qiu-Ling; Su, Xin-Guang

    2012-06-01

    Ibuprofen/ethyl-cellulose (EC)-polyvinylpyrrolidone (PVP) sustained-release composite particles were prepared by using supercritical CO2 anti-solvent technology. With drug loading as the main evaluation index, orthogonal experimental design was used to optimize the preparation process of EC-PVP/ibuprofen composite particles. The experiments such as encapsulation efficiency, particle size distribution, electron microscope analysis, infrared spectrum (IR), differential scanning calorimetry (DSC) and in vitro dissolution were used to analyze the optimal process combination. The orthogonal experimental optimization process conditions were set as follows: crystallization temperature 40 degrees C, crystallization pressure 12 MPa, PVP concentration 4 mgmL(-1), and CO2 velocity 3.5 Lmin(-1). Under the optimal conditions, the drug loading and encapsulation efficiency of ibuprofen/EC-PVP composite particles were 12.14% and 52.21%, and the average particle size of the particles was 27.621 microm. IR and DSC analysis showed that PVP might complex with EC. The experiments of in vitro dissolution showed that ibuprofen/EC-PVP composite particles had good sustained-release effect. Experiment results showed that, ibuprofen/EC-PVP sustained-release composite particles can be prepared by supercritical CO2 anti-solvent technology.

  8. Eddy covariance carbonyl sulfide flux measurements with a quantum cascade laser absorption spectrometer

    NASA Astrophysics Data System (ADS)

    Gerdel, Katharina; Spielmann, Felix M.; Hammerle, Albin; Wohlfahrt, Georg

    2016-04-01

    Carbonyl sulfide (COS) is the most abundant sulfur containing trace gas present in the troposphere at concentrations of around 500 ppt. Recent interest in COS by the ecosystem-physiological community has been sparked by the fact that COS co-diffuses into plant leaves pretty much the same way as carbon dioxide (CO2) does, but in contrast to CO2, COS is not known to be emitted by plants. Thus uptake of COS by vegetation has the potential to be used as a tracer for canopy gross photosynthesis, which cannot be measured directly, however represents a key term in the global carbon cycle. Since a few years, quantum cascade laser absorption spectrometers (QCLAS) are commercially available with the precision, sensitivity and time response suitable for eddy covariance (EC) flux measurements. While there exist a handful of published reports on EC flux measurements in the recent literature, no rigorous investigation of the applicability of QCLAS for EC COS flux measurements has been carried out so far, nor have been EC processing and QA/QC steps developed for carbon dioxide and water vapor flux measurements within FLUXNET been assessed for COS. The aim of this study is to close this knowledge gap, to discuss critical steps in the post-processing chain of COS EC flux measurements and to devise best-practice guidelines for COS EC flux data processing. To this end we collected EC COS (and CO2, H2O and CO) flux measurements above a temperate mountain grassland in Austria over the vegetation period 2015 with a commercially available QCLAS. We discuss various aspects of EC data post-processing, in particular issues with the time-lag estimation between sonic anemometer and QCLAS signals and QCLAS time series detrending, as well as QA/QC, in particular flux detection limits, random flux uncertainty, the interaction of various processing steps with common EC QA/QC filters (e.g. detrending and stationarity tests), u*-filtering, etc.

  9. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    PubMed

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  10. Characterization of konjac glucomannan-ethyl cellulose film formation via microscopy.

    PubMed

    Xiao, Man; Wan, Li; Corke, Harold; Yan, Wenli; Ni, Xuewen; Fang, Yapeng; Jiang, Fatang

    2016-04-01

    Konjac glucomannan-ethyl cellulose (KGM-EC, 7:3, w/w) blended film shows good mechanical and moisture resistance properties. To better understand the basis for the KGM-EC film formation, optical microscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), and atomic force microscopy (AFM) were used to observe the formation of the film from emulsion. Optical microscopy images showed that EC oil droplets were homogeneously dispersed in KGM water phase without obviously coalescence throughout the entire drying process. SEM images showed the surface and cross-sectional structures of samples maintained continuous and homogeneous appearance from the emulsion to dried film. AFM images indicated that KGM molecules entangled EC molecules in the emulsion. Interactions between KGM and EC improved the stability of KGM-EC emulsion, and contributed to uniformed structures of film formation. Based on these output information, a schematic model was built to elucidate KGM-EC film-forming process. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Field-scale electrolysis/ceramic membrane system for the treatment of sewage from decentralized small communities.

    PubMed

    Son, Dong-Jin; Kim, Woo-Yeol; Yun, Chan-Young; Kim, Dae-Gun; Chang, Duk; Sunwoo, Young; Hong, Ki-Ho

    2017-07-05

    The electrolysis process adopting copper electrodes and ceramic membrane with pore sizes of 0.1-0.2 μm were consisted to a system for the treatment of sewage from decentralized small communities. The system was operated under an HRT of 0.1 hour, voltage of 24 V, and TMP of 0.05 MPa. The system showed average removals of organics, nitrogen, phosphorus, and solids of up to 80%, 52%, 92%, and 100%, respectively. Removal of organics and nitrogen dramatically increased in proportion to increment of influent loading. Phosphorus and solids were remarkably eliminated by both electro-coagulation and membrane filtration. The residual particulate constituents could also be removed successfully through membrane process. A system composed of electrolysis process with ceramic membrane would be a compact, reliable, and flexible option for the treatment of sewage from decentralized small communities.

  12. Mass spectrometric methods for monitoring redox processes in electrochemical cells.

    PubMed

    Oberacher, Herbert; Pitterl, Florian; Erb, Robert; Plattner, Sabine

    2015-01-01

    Electrochemistry (EC) is a mature scientific discipline aimed to study the movement of electrons in an oxidation-reduction reaction. EC covers techniques that use a measurement of potential, charge, or current to determine the concentration or the chemical reactivity of analytes. The electrical signal is directly converted into chemical information. For in-depth characterization of complex electrochemical reactions involving the formation of diverse intermediates, products and byproducts, EC is usually combined with other analytical techniques, and particularly the hyphenation of EC with mass spectrometry (MS) has found broad applicability. The analysis of gases and volatile intermediates and products formed at electrode surfaces is enabled by differential electrochemical mass spectrometry (DEMS). In DEMS an electrochemical cell is sampled with a membrane interface for electron ionization (EI)-MS. The chemical space amenable to EC/MS (i.e., bioorganic molecules including proteins, peptides, nucleic acids, and drugs) was significantly increased by employing electrospray ionization (ESI)-MS. In the simplest setup, the EC of the ESI process is used to analytical advantage. A limitation of this approach is, however, its inability to precisely control the electrochemical potential at the emitter electrode. Thus, particularly for studying mechanistic aspects of electrochemical processes, the hyphenation of discrete electrochemical cells with ESI-MS was found to be more appropriate. The analytical power of EC/ESI-MS can further be increased by integrating liquid chromatography (LC) as an additional dimension of separation. Chromatographic separation was found to be particularly useful to reduce the complexity of the sample submitted either to the EC cell or to ESI-MS. Thus, both EC/LC/ESI-MS and LC/EC/ESI-MS are common. © 2013 The Authors. Mass Spectrometry Reviews published by Wiley Periodicals, Inc.

  13. Mass spectrometric methods for monitoring redox processes in electrochemical cells

    PubMed Central

    Oberacher, Herbert; Pitterl, Florian; Erb, Robert; Plattner, Sabine

    2015-01-01

    Electrochemistry (EC) is a mature scientific discipline aimed to study the movement of electrons in an oxidation–reduction reaction. EC covers techniques that use a measurement of potential, charge, or current to determine the concentration or the chemical reactivity of analytes. The electrical signal is directly converted into chemical information. For in-depth characterization of complex electrochemical reactions involving the formation of diverse intermediates, products and byproducts, EC is usually combined with other analytical techniques, and particularly the hyphenation of EC with mass spectrometry (MS) has found broad applicability. The analysis of gases and volatile intermediates and products formed at electrode surfaces is enabled by differential electrochemical mass spectrometry (DEMS). In DEMS an electrochemical cell is sampled with a membrane interface for electron ionization (EI)-MS. The chemical space amenable to EC/MS (i.e., bioorganic molecules including proteins, peptides, nucleic acids, and drugs) was significantly increased by employing electrospray ionization (ESI)-MS. In the simplest setup, the EC of the ESI process is used to analytical advantage. A limitation of this approach is, however, its inability to precisely control the electrochemical potential at the emitter electrode. Thus, particularly for studying mechanistic aspects of electrochemical processes, the hyphenation of discrete electrochemical cells with ESI-MS was found to be more appropriate. The analytical power of EC/ESI-MS can further be increased by integrating liquid chromatography (LC) as an additional dimension of separation. Chromatographic separation was found to be particularly useful to reduce the complexity of the sample submitted either to the EC cell or to ESI-MS. Thus, both EC/LC/ESI-MS and LC/EC/ESI-MS are common. PMID:24338642

  14. EMERGING TECHNOLOGY SUMMARY: ELECTRO-PURE ALTERNATING CURRENT ELECTROCOAGULATION

    EPA Science Inventory

    The Superfund Innovative Technology Evaluation (SITE) Program was authorized as part of the 1986 amendments to the Superfund legislation. It represents a joint effort between the U.S. Environmental Protection Agency’s (EPA) Office of Research and Development and Office of Solid W...

  15. [Preparation of curcumin-EC sustained-release composite particles by supercritical CO2 anti-solvent technology].

    PubMed

    Bai, Wei-li; Yan, Ting-yuan; Wang, Zhi-xiang; Huang, De-chun; Yan, Ting-xuan; Li, Ping

    2015-01-01

    Curcumin-ethyl-cellulose (EC) sustained-release composite particles were prepared by using supercritical CO2 anti-solvent technology. With drug loading and yield of inclusion complex as evaluation indexes, on the basis of single factor tests, orthogonal experimental design was used to optimize the preparation process of curcumin-EC sustained-release composite particles. The experiments such as drug loading, yield, particle size distribution, electron microscope analysis (SEM) , infrared spectrum (IR), differential scanning calorimetry (DSC) and in vitro dissolution were used to analyze the optimal process combination. The orthogonal experimental optimization process conditions were set as follows: crystallization temperature 45 degrees C, crystallization pressure 10 MPa, curcumin concentration 8 g x L(-1), solvent flow rate 0.9 mL x min(-1), and CO2 velocity 4 L x min(-1). Under the optimal conditions, the average drug loading and yield of curcumin-EC sustained-release composite particles were 33.01% and 83.97%, and the average particle size of the particles was 20.632 μm. IR and DSC analysis showed that curcumin might complex with EC. The experiments of in vitro dissolution showed that curcumin-EC composite particles had good sustained-release effect. Curcumin-EC sustained-release composite particles can be prepared by supercritical CO2 anti-solvent technology.

  16. Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes

    PubMed Central

    2014-01-01

    Arsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment technology for arsenic removal from aqueous solutions. The effects of parameters such as initial pH, current density, initial concentration, supporting electrolyte type and stirring speed on removal efficiency were investigated. It has been observed that initial pH was highly effective on the arsenic removal efficiency. The highest removal efficiency was observed at initial pH = 4. The obtained experimental results showed that the efficiency of arsenic removal increased with increasing current density and decreased with increasing arsenic concentration in the solution. Supporting electrolyte had not significant effects on removal, adding supporting electrolyte decreased energy consumption. The effect of stirring speed on removal efficiency was investigated and the best removal efficiency was at the 150 rpm. Under the optimum conditions of initial pH 4, current density of 0.54 mA/cm2, stirring speed of 150 rpm, electrolysis time of 30 minutes, removal was obtained as 99.50%. Energy consumption in the above conditions was calculated as 0.33 kWh/m3. Electrocoagulation with iron electrodes was able to bring down 50 mg/L arsenic concentration to less than 10 μg/L at the end of electrolysis time of 45 minutes with low electrical energy consumption as 0.52 kWh/m3. PMID:24991426

  17. Removal of colour, turbidity, oil and grease for slaughterhouse wastewater using electrocoagulation method

    NASA Astrophysics Data System (ADS)

    Yusoff, Mohd Suffian; Azwan, Azlyza Mohd; Zamri, Mohd Faiz Muaz Ahmad; Aziz, Hamidi Abdul

    2017-10-01

    In this study electrocoagulation method is used to treat slaughterhouse wastewaters. The aim of this study is to determine the efficiency of electrocoagulation method for the removal of colour, turbidity, oil and grease of slaughterhouse wastewaters. The factors of electrode types, and voltage applied during treatment are the study parameters. The types of electrode used are Aluminium (Al) grade 6082 and Iron (Fe) grade 1050. Meanwhile, the ranges of voltage applied are 2, 4, 6, 8 volts at a time interval of 10, 20 and 30 minutes respectively. The effect of these factors on the removal of fat oil and grease (FOG), colour and turbidity are analyzed. The results show maximum removal of FOG, colour and turbidity are recorded using Fe electrode at 8 V of applied voltage with 30 minutes of treatment time. The increase in treatment time of the cell will also increase the amount of hydrogen bubbles at the cathode which results in a greater upwards flux and a faster removal of FOG,, turbidity and colour. The removal of FOG, colour and turbidity are 98%, 92% and 91 % respectively. Meanwhile, by using Al electrodes in the same condition, the removal of FOG, colour and turbidity are 91%, 85% and 87 % respectively. Whereas by using Fe-Al as electrodes pairs, the removal of FOG, colour and turbidity are found to be at 90%, 87% and 76 % respectively. In this case, the Fe-Fe pair electrodes have been proven to provide better performance for FOG, colour and turbidity removals of slaughterhouse wastewaters. Therefore, it is feasible to be considered as an alternative method for wastewater treatment.

  18. [Treatment results for different categories of vaginal intraepithelial neoplasia with electrocoagulation, 5-fluorouracil and combined treatment].

    PubMed

    Veloz-Martínez, María Guadalupe; Quintana-Romero, Verónica; Contreras-Morales, María del Rosario Sandra; Jiménez-Vieyra, Carlos Ramón

    2015-10-01

    Vaginal intraepithelial neoplasia (VAIN) represents a variety of changes that initiate as an intraepithelial squamous lesion with the possibility of resulting in cancer. To compare the results of the treatment for the different categories of VAIN with electrocoagulation, 5-fluorouracil and combined treatment. Observational an analytical study. We stablished groups according to the category of VAIN evaluating and comparing remission, persistence, recurrence, or progression of the disease ac- cording to the received treatment, with a 1-year follow up. The results were compared by chi2 and Kruskal Wallis. The statistics analysis was done with the SPSS program version 20. One hundred thirty seven patients between 20 and 81 years of age (mean age: 52.49 years) were included. Seventy-four percent of the patients had a history of premalignant or malignant cervical lesions. Seventy-four patients had VAIN I, 34 patients had VAIN II, 22 patients had VAIN III and there were seven cases of vaginal carcinoma in situ. Fifty-eight patients were treated with electrocoagulation, 55 patients were treated with 5-FU, 16 patients had combined treatment, and eight patients received expectant management. Sixty three percent of patients had total remission of the lesion, 34% had persistence and 3% showed progression, and there were no cases of recurrence. Results were better in patients with VAIN I treated with 5-FU (bigger percentage of remission P .026), for the remaining categories of VAIN, no treatment showed superior results. The superior response occurs in patients with VAIN I treated with 5-FU. None of the treatments achieves a 100% remission. The VAIN frequency is high, patients with a history of malignant or premalignant cervical pathology should undergo a closer surveillance through cytocolposcopic control with respect to the remaining population.

  19. Mechanism of T7 RNAP pausing and termination at the T7 concatemer junction: a local change in transcription bubble structure drives a large change in transcription complex architecture.

    PubMed

    Nayak, Dhananjaya; Siller, Sylvester; Guo, Qing; Sousa, Rui

    2008-02-15

    The T7RNA polymerase (RNAP) elongation complex (EC) pauses and is destabilized at a unique 8 nucleotide (nt) sequence found at the junction of the head-to-tail concatemers of T7 genomic DNA generated during T7 DNA replication. The paused EC may recruit the T7 DNA processing machinery, which cleaves the concatemerized DNA within this 8 nt concatemer junction (CJ). Pausing of the EC at the CJ involves structural changes in both the RNAP and transcription bubble. However, these structural changes have not been fully defined, nor is it understood how the CJ sequence itself causes the EC to change its structure, to pause, and to become less stable. Here we use solution and RNAP-tethered chemical nucleases to probe the CJ transcript and changes in the EC structure as the polymerase pauses and terminates at the CJ. Together with extensive mutational scanning of regions of the polymerase that are likely to be involved in recognition of the CJ, we are able to develop a description of the events that occur as the EC transcribes through the CJ and subsequently pauses. In this process, a local change in the structure of the transcription bubble drives a large change in the architecture of the EC. This altered EC structure may then serve as the signal that recruits the processing machinery to the CJ.

  20. Navy MANTECH Program Fiscal Year 2002 Annual Report

    DTIC Science & Technology

    2003-04-01

    Journal of Materials Engineering and Performance, Vol. 10, No 6. K. Kannan and J. J. Valencia Field-Scale Demonstration of Electrocoagulation and...Naval Air Systems Command / NADEP CP $741,000 Abrasive Flow Machining (coatings removal ) evaluation for repair of F404 turbine blade engine

  1. [In-transit metastasis in melanoma: Efficacy of topical imiquimod combined with carbon dioxide laser or with electrocautery].

    PubMed

    Elfatoiki, F-Z; Longvert, C; Clerici, T; Bourgault-Villada, I; Roudier-Pujol, C; Vasseur, E; Saiag, P

    2014-02-01

    In-transit metastases in cutaneous melanoma are common and difficult to manage. Therapy is mainly palliative. Use of topical imiquimod has been assessed for surface metastases. We report on four patients with cutaneous melanoma metastases treated with topical imiquimod associated with carbon dioxide laser in the first two patients and with electrocoagulation in the two others. For two patients, we noted complete regression of the lesions after 15 and 18 months. For the two others, treatment was stopped after 9 to 10 months because of progression of subcutaneous metastasis and distant metastasis. Topical imiquimod is an alternative treatment used in superficial in-transit metastasis of melanoma. Its use as a monotherapy is sometimes ineffective. We elected to use combined pre-treatment with carbon dioxide laser or electrocoagulation in order to potentiate the action of imiquimod. This simple and inexpensive therapeutic strategy constitutes a palliative treatment that can allow prolonged local control of cutaneous metastasis. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  2. Mechanism of Electro-Coagulation with Al/Fe Periodically Reversing Treating Berberine Pharmaceutical Wastewater

    NASA Astrophysics Data System (ADS)

    Sun, Zhaonan; Liu, Zheng; Hu, Xiaomin

    2017-05-01

    The method of treating pharmaceutical wastewater by electro-coagulation with Al/Fe periodically reversing (ECPR) was proposed based on traditional electrochemical method. The principle of ECPR was generalized. Mechanism of ECPR to treat berberine pharmaceutical wastewater was investigated. Treatability and mechanism studies were conducted under laboratory conditions. For berberine wastewater (800 mg/L), decolourization efficiency and COD removal efficiency were highest to 98% and 95% respectively when voltage was 8V, reaction time was 60 min, alternating period was 10 S electrolyte concentration was 0.015 mol/L, stirring speed was 750 rpm, pH value was 3-10 and distance between two plates was 0.6 cm. For removal berberine, flocculation, floatation and oxidation provided 73%, 8% and 18% removal efficiency, which can be inferred by analysing UV-visible absorption spectrum, acidification experiment, EDTA shielding experiment, structure-activity relationship, oxidation and floatation. Meanwhile decolourization and COD removal conformed to apparent pseudo-first order and zero-order kinetics for 200mg/L and 400-1000 mg/L berberine wastewater respectively.

  3. Removal of oil and grease from automobile garage wastewater using electrocoagulation

    NASA Astrophysics Data System (ADS)

    Manilal, A. M.; Harinarayanan Nampoothiri, M. G.; Soloman, P. A.

    2017-06-01

    Wastewater from automobile garages and workshops is an important contributor to the water pollution. Oil and grease is one of the major content of wastewater from vehicle garages. Wastewater from a public transport depot at Thrissur district in Kerala, India was collected for the study. A batch reactor has been devised to assess the efficacy of electrocoagulation in removing oil and grease from the wastewater. Aluminium and iron were tested as the anode material with stainless steel as cathode. Experiments were conducted to investigate the effect of various operating parameters such as current density, pH, time and salt concentration on oil and grease removal. The results shown that aluminium is superior to iron in removing the oil and grease from the wastewater. The reactor with aluminium as anode was able to remove 90.8 % of the oil and grease at a current density of 0.6 A/dm2 in 15 minutes. The calculated specific energy consumption is also less for aluminium in comparison with iron.

  4. Analysis of the release process of phenylpropanolamine hydrochloride from ethylcellulose matrix granules IV.(1)) Evaluation of the controlled release properties for in vivo and in vitro release systems.

    PubMed

    Fukui, Atsuko; Fujii, Ryuta; Yonezawa, Yorinobu; Sunada, Hisakazu

    2007-11-01

    In the pharmaceutical preparation of a controlled release drug, it is very important and necessary to understand the release properties. The dissolution test is a very important and useful method for understanding and predicting drug-release properties. It was readily confirmed in the previous paper that the release process could be assessed quantitatively by a combination of the square-root time law and cube-root law equations for ethylcellulose (EC) matrix granules of phenylpropanolamine hydrochloride (PPA). In this paper EC layered granules were used in addition to EC matrix. The relationship between release property and the concentration of PPA in plasma after administration using beagle dogs were examined. Then it was confirmed that the correlativity for EC layered granules and EC matrix were similar each other. Therefore, it was considered that the dissolution test is useful for prediction of changes in concentration of PPA in the blood with time. And it was suggested that EC layered granules were suitable as a controlled release system as well as EC matrix.

  5. Propositional Versus Dual-Process Accounts of Evaluative Conditioning: I. The Effects of Co-Occurrence and Relational Information on Implicit and Explicit Evaluations.

    PubMed

    Hu, Xiaoqing; Gawronski, Bertram; Balas, Robert

    2017-01-01

    Evaluative conditioning (EC) is defined as the change in the evaluation of a conditioned stimulus (CS) due to its pairing with a valenced unconditioned stimulus (US). According to propositional accounts, EC effects should be qualified by the relation between the CS and the US. Dual-process accounts suggest that relational information should qualify EC effects on explicit evaluations, whereas implicit evaluations should reflect the frequency of CS-US co-occurrences. Experiments 1 and 2 showed that, when relational information was provided before the encoding of CS-US pairings, it moderated EC effects on explicit, but not implicit, evaluations. In Experiment 3, relational information moderated EC effects on both explicit and implicit evaluations when it was provided simultaneously with CS-US pairings. Frequency of CS-US pairings had no effect on implicit evaluations. Although the results can be reconciled with both propositional and dual-process accounts, they are more parsimoniously explained by propositional accounts.

  6. Colloidal and electrochemical aspects of copper-CMP

    NASA Astrophysics Data System (ADS)

    Sun, Yuxia

    Copper based interconnects with low dielectric constant layers are currently used to increase interconnect densities and reduce interconnect time delays in integrated circuits. The technology used to develop copper interconnects involves Chemical Mechanical Planarization (CMP) of copper films deposited on low-k layers (silica or silica based films), which is carried out using slurries containing abrasive particles. One issue using such a structure is copper contamination over dielectric layers (SiO2 film), if not reduced, this contamination will cause current leakage. In this study, the conditions conducive to copper contamination onto SiO2 films during Cu-CMP process were studied, and a post-CMP cleaning technique was discussed based on experimental results. It was found that the adsorption of copper onto a silica surface is kinetically fast (<0.5 minute). The amount of copper absorbed is pH and concentration dependent and affected by presence of H2O2, complexing agents, and copper corrosion inhibitor Benzotrazole. Based on de-sorption results, DI water alone was unable to reduce adsorbed copper to an acceptable level, especially for adsorption that takes place at a higher pH condition. The addition of complex agent, citric acid, proved effective in suppressing copper adsorption onto oxide silica during polishing or post-CMP cleaning by forming stable copper-CA complexes. Surface Complexation Modeling was used to simulate copper adsorption isotherms and predict the copper contamination levels on SiO2 surfaces. Another issue with the application of copper CMP is its environmental impact. CMP is a costly process due to its huge consumption of pure water and slurry. Additionally, Cu-CMP processing generates a waste stream containing certain amounts of copper and abrasive slurry particles. In this study, the separation technique electrocoagulation was investigated to remove both copper and abrasive slurry particles simultaneously. For effluent containing ˜40 ppm dissolved copper, it was found that ˜90% dissolved copper was removed from the waste streams through electroplating and in-situ chemical precipitation. The amount of copper removed through plating is impacted by membrane surface charge, type/amount of complexing agents, and solid content in the slurry suspension. The slurry particles can be removed ˜90% within 2 hours of EC through multiple mechanisms.

  7. Removal of phthalates and pharmaceuticals from municipal wastewater by graphene adsorption process.

    PubMed

    Yang, Gordon C C; Tang, Pei-Ling

    2016-01-01

    In this work graphene was used for evaluation of its adsorption behavior and performance in removing phthalate esters and pharmaceuticals in municipal wastewater. Di-n-butyl phthalate (DnBP), di-(2-ethylhexyl) phthalate (DEHP), acetaminophen (ACE), caffeine (CAF), cephalexin (CLX), and sulfamethoxazole (SMX) were emerging contaminants (ECs) with detection frequencies over 92% in a one-year monitoring of the occurrence of ECs in influent samples of a sewage treatment plant in Taiwan. Thus, these ECs were selected as the target contaminants for removal by graphene adsorption process. Experimental results showed that the adsorption isotherm data were fitted well to Langmuir model equation. It was also found that the adsorption process obeyed the pseudo-second-order kinetics. A graphene dosage of 0.1 g/L and adsorption time of 12 h were found to be the optimal operating conditions for the ECs of concern in model solutions in a preliminary study. By using the determined optimal operating conditions for removal of such ECs in actual municipal wastewater, removal efficiencies for various ECs were obtained and given as follows: (1) DnBP, 89%, (2) DEHP, 86%, (3) ACE, 43%, (4) CAF, 84%, (5) CLX, 81%, and (6) SMX, 34%.

  8. Modelling the structure of sludge aggregates

    PubMed Central

    Smoczyński, Lech; Ratnaweera, Harsha; Kosobucka, Marta; Smoczyński, Michał; Kalinowski, Sławomir; Kvaal, Knut

    2016-01-01

    ABSTRACT The structure of sludge is closely associated with the process of wastewater treatment. Synthetic dyestuff wastewater and sewage were coagulated using the PAX and PIX methods, and electro-coagulated on aluminium electrodes. The processes of wastewater treatment were supported with an organic polymer. The images of surface structures of the investigated sludge were obtained using scanning electron microscopy (SEM). The software image analysis permitted obtaining plots log A vs. log P, wherein A is the surface area and P is the perimeter of the object, for individual objects comprised in the structure of the sludge. The resulting database confirmed the ‘self-similarity’ of the structural objects in the studied groups of sludge, which enabled calculating their fractal dimension and proposing models for these objects. A quantitative description of the sludge aggregates permitted proposing a mechanism of the processes responsible for their formation. In the paper, also, the impact of the structure of the investigated sludge on the process of sedimentation, and dehydration of the thickened sludge after sedimentation, was discussed. PMID:26549812

  9. Vasohibin-1 is identified as a master-regulator of endothelial cell apoptosis using gene network analysis

    PubMed Central

    2013-01-01

    Background Apoptosis is a critical process in endothelial cell (EC) biology and pathology, which has been extensively studied at protein level. Numerous gene expression studies of EC apoptosis have also been performed, however few attempts have been made to use gene expression data to identify the molecular relationships and master regulators that underlie EC apoptosis. Therefore, we sought to understand these relationships by generating a Bayesian gene regulatory network (GRN) model. Results ECs were induced to undergo apoptosis using serum withdrawal and followed over a time course in triplicate, using microarrays. When generating the GRN, this EC time course data was supplemented by a library of microarray data from EC treated with siRNAs targeting over 350 signalling molecules. The GRN model proposed Vasohibin-1 (VASH1) as one of the candidate master-regulators of EC apoptosis with numerous downstream mRNAs. To evaluate the role played by VASH1 in EC, we used siRNA to reduce the expression of VASH1. Of 10 mRNAs downstream of VASH1 in the GRN that were examined, 7 were significantly up- or down-regulated in the direction predicted by the GRN.Further supporting an important biological role of VASH1 in EC, targeted reduction of VASH1 mRNA abundance conferred resistance to serum withdrawal-induced EC death. Conclusion We have utilised Bayesian GRN modelling to identify a novel candidate master regulator of EC apoptosis. This study demonstrates how GRN technology can complement traditional methods to hypothesise the regulatory relationships that underlie important biological processes. PMID:23324451

  10. Electrocoagulation and nanofiltration integrated process application in purification of bilge water using response surface methodology.

    PubMed

    Akarsu, Ceyhun; Ozay, Yasin; Dizge, Nadir; Elif Gulsen, H; Ates, Hasan; Gozmen, Belgin; Turabik, Meral

    Marine pollution has been considered an increasing problem because of the increase in sea transportation day by day. Therefore, a large volume of bilge water which contains petroleum, oil and hydrocarbons in high concentrations is generated from all types of ships. In this study, treatment of bilge water by electrocoagulation/electroflotation and nanofiltration integrated process is investigated as a function of voltage, time, and initial pH with aluminum electrode as both anode and cathode. Moreover, a commercial NF270 flat-sheet membrane was also used for further purification. Box-Behnken design combined with response surface methodology was used to study the response pattern and determine the optimum conditions for maximum chemical oxygen demand (COD) removal and minimum metal ion contents of bilge water. Three independent variables, namely voltage (5-15 V), initial pH (4.5-8.0) and time (30-90 min) were transformed to coded values. The COD removal percent, UV absorbance at 254 nm, pH value (after treatment), and concentration of metal ions (Ti, As, Cu, Cr, Zn, Sr, Mo) were obtained as responses. Analysis of variance results showed that all the models were significant except for Zn (P > 0.05), because the calculated F values for these models were less than the critical F value for the considered probability (P = 0.05). The obtained R(2) and Radj(2) values signified the correlation between the experimental data and predicted responses: except for the model of Zn concentration after treatment, the high R(2) values showed the goodness of fit of the model. While the increase in the applied voltage showed negative effects, the increases in time and pH showed a positive effect on COD removal efficiency; also the most effective linear term was found as time. A positive sign of the interactive coefficients of the voltage-time and pH-time systems indicated synergistic effect on COD removal efficiency, whereas interaction between voltage and pH showed an antagonistic effect.

  11. Modeling human endothelial cell transformation in vascular neoplasias

    PubMed Central

    Wen, Victoria W.; MacKenzie, Karen L.

    2013-01-01

    Endothelial cell (EC)-derived neoplasias range from benign hemangioma to aggressive metastatic angiosarcoma, which responds poorly to current treatments and has a very high mortality rate. The development of treatments that are more effective for these disorders will be expedited by insight into the processes that promote abnormal proliferation and malignant transformation of human ECs. The study of primary endothelial malignancy has been limited by the rarity of the disease; however, there is potential for carefully characterized EC lines and animal models to play a central role in the discovery, development and testing of molecular targeted therapies for vascular neoplasias. This review describes molecular alterations that have been identified in EC-derived neoplasias, as well as the processes that underpin the immortalization and tumorigenic conversion of ECs. Human EC lines, established through the introduction of defined genetic elements or by culture of primary tumor tissue, are catalogued and discussed in relation to their relevance as models of vascular neoplasia. PMID:24046386

  12. Global architecture of the F-actin cytoskeleton regulates cell shape-dependent endothelial mechanotransduction.

    PubMed

    Shao, Yue; Mann, Jennifer M; Chen, Weiqiang; Fu, Jianping

    2014-03-01

    Uniaxial stretch is an important biophysical regulator of cell morphology (or shape) and functions of vascular endothelial cells (ECs). However, it is unclear whether and how cell shape can independently regulate EC mechanotransductive properties under uniaxial stretch. Herein, utilizing a novel uniaxial cell-stretching device integrated with micropost force sensors, we reported the first experimental evidence showing cell shape-dependent EC mechanotransduction via cytoskeleton (CSK) contractile forces in response to uniaxial stretch. Combining experiments and theoretical modeling from first principles, we showed that it was the global architecture of the F-actin CSK that instructed the cell shape-dependent EC mechanotransductive process. Furthermore, a cell shape-dependent nature was relayed in EC mechanotransduction via dynamic focal adhesion (FA) assembly. Our results suggested a novel mechanotransductive process in ECs wherein the global architecture of the F-actin CSK, governed by cell shape, controls mechanotransduction via CSK contractile forces and force-dependent FA assembly under uniaxial stretch.

  13. BLT-EC (Breach, Leach and Transport-Equilibrium Chemistry) data input guide. A computer model for simulating release and coupled geochemical transport of contaminants from a subsurface disposal facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacKinnon, R.J.; Sullivan, T.M.; Kinsey, R.R.

    1997-05-01

    The BLT-EC computer code has been developed, implemented, and tested. BLT-EC is a two-dimensional finite element computer code capable of simulating the time-dependent release and reactive transport of aqueous phase species in a subsurface soil system. BLT-EC contains models to simulate the processes (container degradation, waste-form performance, transport, chemical reactions, and radioactive production and decay) most relevant to estimating the release and transport of contaminants from a subsurface disposal system. Water flow is provided through tabular input or auxiliary files. Container degradation considers localized failure due to pitting corrosion and general failure due to uniform surface degradation processes. Waste-form performancemore » considers release to be limited by one of four mechanisms: rinse with partitioning, diffusion, uniform surface degradation, and solubility. Transport considers the processes of advection, dispersion, diffusion, chemical reaction, radioactive production and decay, and sources (waste form releases). Chemical reactions accounted for include complexation, sorption, dissolution-precipitation, oxidation-reduction, and ion exchange. Radioactive production and decay in the waste form is simulated. To improve the usefulness of BLT-EC, a pre-processor, ECIN, which assists in the creation of chemistry input files, and a post-processor, BLTPLOT, which provides a visual display of the data have been developed. BLT-EC also includes an extensive database of thermodynamic data that is also accessible to ECIN. This document reviews the models implemented in BLT-EC and serves as a guide to creating input files and applying BLT-EC.« less

  14. An evolving new paradigm: endothelial cells – conditional innate immune cells

    PubMed Central

    2013-01-01

    Endothelial cells (ECs) are a heterogeneous population that fulfills many physiological processes. ECs also actively participate in both innate and adaptive immune responses. ECs are one of the first cell types to detect foreign pathogens and endogenous metabolite-related danger signals in the bloodstream, in which ECs function as danger signal sensors. Treatment with lipopolysaccharide activates ECs, causing the production of pro-inflammatory cytokines and chemokines, which amplify the immune response by recruiting immune cells. Thus, ECs function as immune/inflammation effectors and immune cell mobilizers. ECs also induce cytokine production by immune cells, in which ECs function as immune regulators either by activating or suppressing immune cell function. In addition, under certain conditions, ECs can serve as antigen presenting cells (antigen presenters) by expressing both MHC I and II molecules and presenting endothelial antigens to T cells. These facts along with the new concept of endothelial plasticity suggest that ECs are dynamic cells that respond to extracellular environmental changes and play a meaningful role in immune system function. Based on these novel EC functions, we propose a new paradigm that ECs are conditional innate immune cells. This paradigm provides a novel insight into the functions of ECs in inflammatory/immune pathologies. PMID:23965413

  15. An evolving new paradigm: endothelial cells--conditional innate immune cells.

    PubMed

    Mai, Jietang; Virtue, Anthony; Shen, Jerry; Wang, Hong; Yang, Xiao-Feng

    2013-08-22

    Endothelial cells (ECs) are a heterogeneous population that fulfills many physiological processes. ECs also actively participate in both innate and adaptive immune responses. ECs are one of the first cell types to detect foreign pathogens and endogenous metabolite-related danger signals in the bloodstream, in which ECs function as danger signal sensors. Treatment with lipopolysaccharide activates ECs, causing the production of pro-inflammatory cytokines and chemokines, which amplify the immune response by recruiting immune cells. Thus, ECs function as immune/inflammation effectors and immune cell mobilizers. ECs also induce cytokine production by immune cells, in which ECs function as immune regulators either by activating or suppressing immune cell function. In addition, under certain conditions, ECs can serve as antigen presenting cells (antigen presenters) by expressing both MHC I and II molecules and presenting endothelial antigens to T cells. These facts along with the new concept of endothelial plasticity suggest that ECs are dynamic cells that respond to extracellular environmental changes and play a meaningful role in immune system function. Based on these novel EC functions, we propose a new paradigm that ECs are conditional innate immune cells. This paradigm provides a novel insight into the functions of ECs in inflammatory/immune pathologies.

  16. Notochord-derived BMP antagonists inhibit endothelial cell generation and network formation.

    PubMed

    Bressan, Michael; Davis, Patricia; Timmer, John; Herzlinger, Doris; Mikawa, Takashi

    2009-02-01

    Embryonic blood vessel formation is initially mediated through the sequential differentiation, migration, and assembly of endothelial cells (ECs). While many molecular signals that promote vascular development have been identified, little is known about suppressors of this process. In higher vertebrates, including birds and mammals, the vascular network forms throughout the embryonic disk with the exception of a region along the midline. We have previously shown that the notochord is responsible for the generation and maintenance of the avascular midline and that BMP antagonists expressed by this embryonic tissue, including Noggin and Chordin, can mimic this inhibitory role. Here we report that the notochord suppresses the generation of ECs from the mesoderm both in vivo and in vitro. We also report that the notochord diminishes the ability of mature ECs to organize into a primitive plexus. Furthermore, Noggin mimics notochord-based inhibition by preventing mesodermal EC generation and mature EC network formation. These findings suggest that the mesoderm surrounding the midline is competent to give rise to ECs and to form blood vessels, but that notochord derived-BMP antagonists suppress EC differentiation and maturation processes leading to inhibition of midline vessel formation.

  17. The endocannabinoid system in anxiety, fear memory and habituation

    PubMed Central

    Ruehle, S; Rey, A Aparisi; Remmers, F

    2012-01-01

    Evidence for the involvement of the endocannabinoid system (ECS) in anxiety and fear has been accumulated, providing leads for novel therapeutic approaches. In anxiety, a bidirectional influence of the ECS has been reported, whereby anxiolytic and anxiogenic responses have been obtained after both increases and decreases of the endocannabinoid tone. The recently developed genetic tools have revealed different but complementary roles for the cannabinoid type 1 (CB1) receptor on GABAergic and glutamatergic neuronal populations. This dual functionality, together with the plasticity of CB1 receptor expression, particularly on GABAergic neurons, as induced by stressful and rewarding experiences, gives the ECS a unique regulatory capacity for maintaining emotional homeostasis. However, the promiscuity of the endogenous ligands of the CB1 receptor complicates the interpretation of experimental data concerning ECS and anxiety. In fear memory paradigms, the ECS is mostly involved in the two opposing processes of reconsolidation and extinction of the fear memory. Whereas ECS activation deteriorates reconsolidation, proper extinction depends on intact CB1 receptor signalling. Thus, both for anxiety and fear memory processing, endocannabinoid signalling may ensure an appropriate reaction to stressful events. Therefore, the ECS can be considered as a regulatory buffer system for emotional responses. PMID:21768162

  18. APOC3 induces endothelial dysfunction through TNF-α and JAM-1.

    PubMed

    Tao, Yun; Xiong, Yisong; Wang, Huimin; Chu, Shaopeng; Zhong, Renqian; Wang, Jianxin; Wang, Guihua; Ren, Xiumei; Yu, Juan

    2016-09-13

    The fatality rate for cardiovascular disease (CVD) has increased in recent years and higher levels of triglyceride have been shown to be an independent risk factor for atherosclerotic CVD. Dysfunction of endothelial cells (ECs) is also a key factor of CVD. APOC3 is an important molecule in lipid metabolism that is closely associated with hyperlipidemia and an increased risk of developing CVD. But the direct effects of APOC3 on ECs were still unknown. This study was aimed at determining the effects of APOC3 on inflammation, chemotaxis and exudation in ECs. ELISA, qRT-PCR, immunofluorescence, flow cytometry and transwell assays were used to investigate the effects of APOC3 on human umbilical vein endothelial cells (HUVECs). SiRNA-induced TNF-α and JAM-1 silencing were used to observe how APOC3 influenced the inflammatory process in the ECs. Our results showed that APOC3 was closely associated with the inflammatory process in ECs, and that this process was characterized by the increased expression of TNF-α. Inflammatory processes further disrupted the tight junctions (TJs) between HUVECs by causing increased expression of JAM-1. JAM-1 was involved in maintaining the integrity of TJs, and it promoted the assembly of platelets and the exudation of leukocytes. Changes in its expression promoted chemotaxis and the exudation of ECs, which contributed to atherosclerosis. While the integrity of the TJs was disrupted, the adhesion of THP-1 cells to HUVECs was also increased by APOC3. In this study, we describe the mechanism by which APOC3 causes inflammation, chemotaxis and the exudation of ECs, and we suggest that controlling the inflammatory reactions that are caused by APOC3 may be a new method to treat CVD.

  19. Electrocoagulation process to Chemical and Biological Oxygen Demand treatment from carwash grey water in Ahvaz megacity, Iran.

    PubMed

    Mohammadi, Mohammad Javad; Takdastan, Afshin; Jorfi, Sahand; Neisi, Abdolkazem; Farhadi, Majid; Yari, Ahmad Reza; Dobaradaran, Sina; Khaniabadi, Yusef Omidi

    2017-04-01

    In this work, we present the result of an electric coagulation process with iron and aluminum electrodes for removal of chemical and biological oxygen demand (COD and BOD) from grey water in different car washes of Ahvaz, Iran. Nowadays, one of the important dangerous that can contaminate water resources for drinking, agriculture and industrial is Car wash effluent [1,2]. In this study, initial COD and BOD concentration, pH of the solution, voltage power and reaction time was investigated. The concentration level of remaining COD and BOD in samples was measured, using DR/5000 UV-vis HACH spectrophotometer [3,4]. The effects of contact time, initial pH, electrical potential and voltage data on removal of COD and BOD were presented. Statistical analysis of the data was carried out using Special Package for Social Sciences (SPSS 16).

  20. Investigation of a new pH-responsive nanoparticulate pore former for controlled release enteric coating with improved processability and stability.

    PubMed

    Chen, Kuan; Chang, Hao Han R; Shalviri, Alireza; Li, Jason; Lugtu-Pe, Jamie Anne; Kane, Anil; Wu, Xiao Yu

    2017-11-01

    Water-soluble polymers are often used as pore formers to tailor permeability of film-forming hydrophobic polymers on coated dosage forms. However, their addition to a coating formulation could significantly increase the viscosity thus making the coating process difficult. Moreover, the dissolution of pore formers after oral administration could compromise film integrity resulting in undesirable, inconsistent release profiles. Therefore, a non-leaching, pH-responsive nanoparticulate pore former is proposed herein to preserve film integrity and maintain pH-dependent permeability. Poly(methacrylic acid)-polysorbate 80-grafted-starch terpolymer nanoparticles (TPNs) were incorporated within an ethylcellulose (EC) film (TPN-EC) by casting or spray coating. TPNs at 10%wt (pore former level) only increased viscosity of EC coating suspension slightly while conventional pore formers increased the viscosity by 490-11,700%. Negligible leaching of TPNs led to superior mechanical properties of TPN-EC films compared to Eudragit® L-EC films. As pH increased from 1.2 to 6.8, TPN-EC films with 10% pore former level exhibited an 8-fold higher diltiazem permeability compared to Eudragit® L-EC films. The pH-dependent drug release kinetics of diltiazem HCl beads coated with TPN-EC films was tunable by adjusting the pore former level. These results suggest that the TPNs are promising pH-sensitive nanoparticulate pore formers in EC-coated dosage forms. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The influence of executive capacity on selective attention and subsequent processing

    PubMed Central

    Daffner, Kirk R.; Tarbi, Elise C.; Haring, Anna E.; Zhuravleva, Tatyana Y.; Sun, Xue; Rentz, Dorene M.; Holcomb, Phillip J.

    2012-01-01

    Recent investigations that suggest selective attention (SA) is dependent on top-down control mechanisms lead to the expectation that individuals with high executive capacity (EC) would exhibit more robust neural indices of SA. This prediction was tested by using event-related potentials (ERPs) to examine differences in markers of information processing across 25 subjects divided into two groups based on high vs. average EC, as defined by neuropsychological test scores. Subjects performed an experimental task requiring SA to a specified color. In contrast to expectation, individuals with high and average EC did not differ in the size of ERP indices of SA: the anterior Selection Positivity (SP) and posterior Selection Negativity (SN). However, there were substantial differences between groups in markers of subsequent processing, including the anterior N2 (a measure of attentional control) and the P3a (an index of the orienting of attention). EC predicted speed of processing at both early and late attentional stages. Individuals with lower EC exhibited prolonged SN, P3a, and P3b latencies. However, the delays in carrying out SA operations did not account for subsequent delays in decision making, or explain excessive orienting and reduced attentional control mechanisms in response to stimuli that should have been ignored. SN latency, P3 latency, and the size of the anterior N2 made independent contributions to the variance of EC. In summary, our findings suggest that current views regarding the relationship between top-down control mechanisms and SA may need refinement. PMID:22701415

  2. A Patient-Centered, Provider-Facilitated Approach to the Refinement of Nonlinear Frequency Compression Parameters Based on Subjective Preference Ratings of Amplified Sound Quality.

    PubMed

    Johnson, Earl E; Light, Keri C

    2015-09-01

    To evaluate sound quality preferences of participants wearing hearing aids with different strengths of nonlinear frequency compression (NFC) processing versus no NFC processing. Two analysis methods, one without and one with a qualifier as to the magnitude of preferences, were compared for their percent agreement to differentiate a small difference in perceived sound quality as a result of applied NFC processing. A single-blind design was used with participants unaware of the presence or strength of NFC processing (independent variable). The National Acoustic Laboratories-Nonlinear 2 (NAL-NL2) prescription of amplification was chosen because audibility is intentionally not prescribed in the presence of larger sensorineural hearing loss thresholds. A lack of prescribed audibility, when present, was deemed an objective qualifier for NFC. NFC is known to improve the input bandwidth available to listeners when high-frequency audibility is not otherwise available and increasing strengths of NFC were examined. Experimental condition 3 (EC3) was stronger than the manufacturer default (EC2). More aggressive strengths (e.g., EC4 and EC5), however, were expected to include excessive distortion and even reduce the output bandwidth that had been prescribed as audible by NAL-NL2 (EC1). A total of 14 male Veterans with severe high-frequency sensorineural hearing loss. Participant sound quality preference ratings (dependent variable) without a qualifier as to the magnitude of preference were analyzed based on binomial probability theory, as is traditional with paired comparison data. The ratings with a qualifier as to the magnitude of preference were analyzed based on the nonparametric statistic of the Wilcoxon signed rank test. The binomial probability analysis method identified a sound quality preference as well as the nonparametric probability test method. As the strength of NFC increased, more participants preferred the EC with less NFC. Fourteen of 14 participants showed equal preference between EC1 and EC2 perhaps, in part, because EC2 showed no objective improvement in audibility for six of the 14 participants (42%). Thirteen of the 14 participants showed no preference between NAL-NL2 and EC3, but all participants had an objective improvement in audibility. With more NFC than EC3, more and more participants preferred the other EC with less NFC in the paired comparison. By referencing the recommended sensation levels of amplitude compression (e.g., NAL-NL2) in the ear canal of hearing aid wearers, the targeting of NFC parameters can likely be optimized with respect to improvements in effective audibility that may contribute to speech recognition without adversely impacting sound quality. After targeting of NFC parameters, providers can facilitate decisions about the use of NFC parameters (strengths of processing) via sound quality preference judgments using paired comparisons. American Academy of Audiology.

  3. When congruence breeds preference: the influence of selective attention processes on evaluative conditioning.

    PubMed

    Blask, Katarina; Walther, Eva; Frings, Christian

    2017-09-01

    We investigated in two experiments whether selective attention processes modulate evaluative conditioning (EC). Based on the fact that the typical stimuli in an EC paradigm involve an affect-laden unconditioned stimulus (US) and a neutral conditioned stimulus (CS), we started from the assumption that learning might depend in part upon selective attention to the US. Attention to the US was manipulated by including a variant of the Eriksen flanker task in the EC paradigm. Similarly to the original Flanker paradigm, we implemented a target-distracter logic by introducing the CS as the task-relevant stimulus (i.e. the target) to which the participants had to respond and the US as a task-irrelevant distracter. Experiment 1 showed that CS-US congruence modulated EC if the CS had to be selected against the US. Specifically, EC was more pronounced for congruent CS-US pairs as compared to incongruent CS-US pairs. Experiment 2 disentangled CS-US congruence and CS-US compatibility and suggested that it is indeed CS-US stimulus congruence rather than CS-US response compatibility that modulates EC.

  4. Metabolism of substance P and neurokinin A by human vascular endothelium and smooth muscle.

    PubMed

    Wang, L; Sadoun, E; Stephens, R E; Ward, P E

    1994-01-01

    Analysis of SP and NKA metabolism by human vascular endothelium, relative to that in human plasma, identified integrative, multiple pathways for the processing of circulating SP (but not NKA) by angiotensin-converting enzyme (ACE; EC 3.4.15.1), dipeptidyl(amino)peptidase IV (DAP IV; EC 3.4.14.5), and aminopeptidase M (AmM; EC 3.4.11.2). In contrast, SP and NKA, which may diffuse into or be neurally released within the vessel wall, were both metabolized by smooth muscle neutral endopeptidase-24.11 (NEP-24.11; EC 3.4.24.11). Collectively, these studies indicate peptide-specific and site-specific differential processing of SP and NKA by human plasma and vasculature.

  5. A true orthotopic gastric cancer murine model using electrocoagulation.

    PubMed

    Bhullar, Jasneet Singh; Makarawo, Tafadzwa; Subhas, Gokulakkrishna; Alomari, Ahmed; Silberberg, Boris; Tilak, Jacqueline; Decker, Milessa; Mittal, Vijay K

    2013-07-01

    Orthotopic mouse models of human gastric cancer represent an important in vivo tool for testing chemotherapeutic agents and for studying intraluminal factors. Currently, orthotopic mouse models of gastric cancer require an operative procedure involving either injection or implantation of tumor cells in stomach layers. The resultant tumor does not grow from the stomach's mucosal surface, so it does not mimic the human disease process. A low-dose gastric mucosal coagulation was done transorally in the body of stomach using a specially designed polyethylene catheter in 16 female severe combined immunodeficient mice. This was followed by the instillation of SNU-16 human gastric cancer tumor cells (1 × 10(6) cells). Five mice each were euthanized at 1 and 2 months, and 6 mice were euthanized at 3 months. Three control mice underwent electrocoagulation alone and 3 mice underwent cell line instillation alone. Tumors were detected in 11 of 16 experimental mice, but not in the control mice. Tumors were noted in mice at 1 month. Over time, there was an increase in tumor growth and metastasis to lymph nodes and surrounding organs. Histopathologic evaluation showed that the tumors grew from the gastric mucosa. Our model is easy to create and overcomes the limitations of the existing models, as the tumor arises from the stomach's mucosal layer and mimics the human disease in terms of morphology and biologic behavior. This is the first report of a true orthotopic gastric cancer murine model. This model opens new doors for additional studies that were not possible earlier. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Exploring emotional climate in preservice science teacher education

    NASA Astrophysics Data System (ADS)

    Bellocchi, Alberto; Ritchie, Stephen M.; Tobin, Kenneth; Sandhu, Maryam; Sandhu, Satwant

    2013-09-01

    Classroom emotional climates (ECs) are interrelated with students' engagement with university courses. Despite growing interest in emotions and EC research, little is known about the ways in which social interactions and different subject matter mediate ECs in preservice science teacher education classes. In this study we investigated the EC and associated classroom interactions in a preservice science teacher education class. We were interested in the ways in which salient classroom interactions were related to the EC during lessons centered on debates about science-based issues (e.g., nuclear energy alternatives). Participants used audience response technology to indicate their perceptions of the EC. Analysis of conversation for salient video clips and analysis of non-verbal conduct (acoustic parameters, body movements, and facial expressions) supplemented EC data. One key contribution that this study makes to preservice science teacher education is to identify the micro-processes of successful and unsuccessful class interactions that were associated with positive and neutral EC. The structure of these interactions can inform the practice of other science educators who wish to produce positive ECs in their classes. The study also extends and explicates the construct of intensity of EC.

  7. Analysis of the release process of phenylpropanolamine hydrochloride from ethylcellulose matrix granules II. effects of the binder solution on the release process.

    PubMed

    Fukui, Atsuko; Fujii, Ryuta; Yonezawa, Yorinobu; Sunada, Hisakazu

    2004-03-01

    The release properties of phenylpropanolamine hydrochloride (PPA) from ethylcellulose (EC) matrix granules prepared by an extrusion granulation method were examined. The release process could be divided into two parts; the first and second stages were analyzed by applying square-root time law and cube-root law equations, respectively. The validity of the treatments was confirmed by the fitness of a simulation curve with the measured curve. In the first stage, PPA was released from the gel layer of swollen EC in the matrix granules. In the second stage, the drug existing below the gel layer dissolved and was released through the gel layer. The effect of the binder solution on the release from EC matrix granules was also examined. The binder solutions were prepared from various EC and ethanol (EtOH) concentrations. The media changed from a good solvent to a poor solvent with decreasing EtOH concentration. The matrix structure changed from loose to compact with increasing EC concentration. The preferable EtOH concentration region was observed when the release process was easily predictable. The time and release ratio at the connection point of the simulation curves were also examined to determine the validity of the analysis.

  8. Electrochemical pretreatment of waste activated sludge: effect of process conditions on sludge disintegration degree and methane production.

    PubMed

    Ye, Caihong; Yuan, Haiping; Dai, Xiaohu; Lou, Ziyang; Zhu, Nanwen

    2016-11-01

    Waste activated sludge (WAS) requires a long digestion time because of a rate-limiting hydrolysis step - the first phase of anaerobic digestion (AD). Pretreatment can be used prior to AD to facilitate the hydrolysis step and improve the efficiency of WAS digestion. This study evaluated a novel application of electrochemical (EC) technology employed as the pretreatment method prior to AD of WAS, focusing on the effect of process conditions on sludge disintegration and subsequent AD process. A superior process condition of EC pretreatment was obtained by reaction time of 30 min, electrolysis voltage of 20 V, and electrode distance of 5 cm, under which the disintegration degree of WAS ranged between 9.02% and 9.72%. In the subsequent batch AD tests, 206 mL/g volatile solid (VS) methane production in EC pretreated sludge was obtained, which was 20.47% higher than that of unpretreated sludge. The AD time was 19 days shorter for EC pretreated sludge compared to the unpretreated sludge. Additionally, the EC + AD reactor achieved 41.84% of VS removal at the end of AD. The analysis of energy consumption showed that EC pretreatment could be effective in enhancing sludge AD with reduced energy consumption when compared to other pretreatment methods.

  9. Comparison of effectiveness of electrocautery and phenol application in partial matricectomy after partial nail extraction in the treatment of ingrown nails.

    PubMed

    Misiak, Piotr; Terlecki, Artur; Rzepkowska-Misiak, Beata; Wcisło, Szymon; Brocki, Marian

    2014-02-01

    Ingrowing nail also known as onychocryptosis is a common health problem. This disease mostly affects young people, often carrying a considerable amount of socio-economic implications. It's foot problem that usually manifests as inflammation of tissue along the side of a toenail. The aim of the study was to asses and to compare effectiveness of electrocautery and phenol application in partial matrixectomy after partial nail extraction in the treatment of ingrown toenails. The group of 60 patients with ingrowing toenail which was randomized into two groups underwent partial matrixectomy in surgical outpatient clinic between 2009-2013. This group of patients was under surgical observation for 100 days in outpatient clinic. In all operated patients we obtained surgical success however we had 13 recurrences during the follow up period, 5 in the phenolization group and 8 in the electrocoagulation group. There was statistically significant difference between these two techniques, which indicated that matrix phenolization is connected with shortened healing time vs the matrix electrocoagulation.

  10. The process evaluation of two alternative participatory ergonomics intervention strategies for construction companies.

    PubMed

    Visser, Steven; van der Molen, Henk F; Sluiter, Judith K; Frings-Dresen, Monique H W

    2018-03-26

    To gain insight into the process of applying two guidance strategies - face-to-face (F2F) or e-guidance strategy (EC) - of a Participatory Ergonomics (PE) intervention and whether differences between these guidance strategies occur, 12 construction companies were randomly assigned to a strategy. The process evaluation contained reach, dose delivered, dose received, precision, competence, satisfaction and behavioural change of individual workers. Data were assessed by logbooks, and questionnaires and interviews at baseline and/or after six months. Reach was low (1%). Dose delivered (F2F: 63%; EC: 44%), received (F2F: 42%; EC: 16%) were not sufficient. The precision and competence were sufficient for both strategies and satisfaction was strongly affected by dose received. For behavioural change, knowledge (F2F) and culture (EC) changed positively within companies. Neither strategy was delivered as intended. Compliance to the intervention was low, especially for EC. Starting with a face-to-face meeting might lead to higher compliance, especially in the EC group. Practitioner Summary: This study showed that compliance to a face-to-face and an e-guidance strategy is low. To improve the compliance, it is advised to start with a face-to-face meeting to see which parts of the intervention are needed and which guidance strategy can be used for these parts. ISRCTN73075751.

  11. Occurrence and removal of pharmaceuticals, hormones, personal care products, and endocrine disrupters in a full-scale water reclamation plant.

    PubMed

    Tran, Ngoc Han; Gin, Karina Yew-Hoong

    2017-12-01

    This study provided the first comprehensive data on the occurrence and removal of twenty-five target emerging contaminants (ECs) in a full-scale water reclamation plant (WRP) in the Southeast Asian region. Nineteen out of the twenty-five ECs were ubiquitously detected in raw influent samples. Concentrations of the detected ECs in raw influent samples ranged substantially from 44.3 to 124,966ng/L, depending upon the compound and sampling date. The elimination of ECs in full-scale conventional activated sludge (CAS) and membrane bioreactor (MBR) systems at a local WRP was evaluated and compared. Several ECs, such as acetaminophen, atenolol, fenoprofen, indomethacin, ibuprofen, and oxybenzone, exhibited excellent removal efficiencies (>90%) in biological wastewater treatment processes, while some of the investigated compounds (carbamazepine, crotamiton, diclofenac, and iopamidol) appeared to be persistent in the both CAS and MBR systems. Field-based monitoring results showed that MBR outperformed CAS in the elimination of most target ECs. The relationship between molecular characteristics of ECs (i.e. physicochemical properties and structural features) and their removal efficiencies during biological wastewater treatment was also elucidated. Excellent removal efficiencies (>90%) were often noted for ECs with the sole presence of electron donating groups (i.e. phenolic [OH], amine [NH 2 ], methoxy [OCH 3 ], phenoxy [OC 6 H 5 ], or alkyl groups). Conversely, ECs with the absence of electron donating groups or the predominance of strong electron withdrawing groups (e.g. halogenated, carbonyl, carboxyl, and sulfonamide) tended to show poor removal efficiencies (<30%) in biological wastewater treatment processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Lipid Droplet Biogenesis and Function in the Endothelium

    PubMed Central

    Kuo, Andrew; Lee, Monica Y.; Sessa, William C.

    2017-01-01

    Rationale Fatty acids (FA) are transported across the capillary endothelium to parenchymal tissues. However, it is not known how endothelial cells (EC) process a post-prandial surge of FA. Objective This study was designed to characterize lipid droplet (LD) formation and function in EC. Methods and Results LD form and degrade in EC in vivo after FA loading. In cultured EC, LD synthesis and turnover is dynamic and function to protect EC from lipotoxic stress and provide FA for metabolic needs. Conclusions Our results delineate endothelial LD dynamics for the first time, demonstrating their protective role in lipotoxicity, FA utilization and mobilization. PMID:28119423

  13. [Comparative study on Chinese medical syndrome typing and treatment combined different surgical methods for treating clomiphene-resistant polycystic ovary syndrome].

    PubMed

    Zeng, Lei; Zeng, Cheng; Tao, Li-Li

    2012-11-01

    To observe the therapeutic efficacy of Chinese medical syndrome typing and treatment combined cold needle puncture drainage operation or unipolar electrocoagulation drilling technique under laparoscope for treating clomiphene-resistant polycystic ovary syndrome (PCOS). Forty infertility patients with clomiphene-resistant PCOS were assigned to two groups using stratified random sampling method according to age, infertility time, and body mass index, 20 in each group. Patients in Group A were treated with Chinese medical syndrome typing and treatment combined cold needle puncture drainage operation, while those in Group B were treated with Chinese medical syndrome typing and treatment combined unipolar electrocoagulation drilling technique. After operation Chinese herbal treatment was administered to all patients according to syndrome typing. The serum levels of luteinizing hormone (LH), follicle stimulating hormone (FSH), androgen (T), estradiol (E2), and prolactin (PRL) were determined before and after operation. The ovulation was monitored. The pregnancy rate and the pregnancy outcomes were recorded after operation. There was no statistical difference in the 3-month spontaneous ovulation rate or the 1-year pregnancy rate (P > 0.05). The levels of LH, T, and PRL were significantly lower after operation than before operation in the two groups (P < 0.05). The menstruation and ovulation were obviously improved after operation. The total ovulation rate was 95% (19/20) in Group A. Successful pregnancy occurred in 15 cases of Group A. Ovarian hyperstimulation syndrome (OHSS) occurred in 1 case of Group A. The total ovulation rate was 90% (18/20) in Group B. Successful pregnancy occurred in 13 cases of Group B. Hypovaria occurred in 1 case of Group B. Luteinized unruptured follicle (LUFS) occurred in 2 cases of Group A and 1 case of Group B. Chinese medical syndrome typing and treatment combined cold needle puncture drainage operation or unipolar electrocoagulation drilling technique could effectively promote the ovulation. The two methods showed similar therapeutic effects.

  14. Ultrasound guided electrocoagulation in patients with chronic non‐insertional Achilles tendinopathy: a pilot study

    PubMed Central

    Boesen, M Ilum; Torp‐Pedersen, S; Koenig, M Juhl; Christensen, R; Langberg, H; Hölmich, P; Nielsen, M Bachmann; Bliddal, H

    2006-01-01

    Background High resolution colour Doppler ultrasound shows intratendinous Doppler activity in patients with chronic Achilles tendinopathy. Treatment of this neovascularisation with sclerosing therapy seems to relieve the pain. However, the procedure often has to be repeated. Objective To investigate the effect of electrocoagulation of the neovessels on tendon pain and tendon vascularity in patients with chronic Achilles tendinopathy. Methods Colour Doppler ultrasound guided electrocoagulation was used on vessels in the ventral portion of the Achilles tendon in 11 patients (seven men, four women, mean age 41 years) with painful chronic mid‐portion Achilles tendinosis. A unipolar coagulation device was used. Results One patient dropped out after two months (dissatisfied with the results). The remaining 10 patients (91%) were satisfied. These 10 patients were still satisfied at six months of follow up and had returned to their previous level of activity. All 10 patients were “cured” after one treatment. The patient who dropped out received two treatments because of lack of progress. There was significantly reduced pain (Likert pain scale, 0–10) during activity, from a median of 7 (range 4 to 10) at baseline to 0 (0 to 8) at six months' follow up (p<0.005); and at rest, from 1.5 (1 to 5) to 0 (0 to 8) (p = 0.005). In all patients, vascularisation was unchanged at the six months follow up, with no significant change in semiquantitative or quantitative colour scoring. Conclusions Coagulation in the area with vessels entering the tendon appears to be effective treatment for painful chronic mid‐tendinous Achilles tendinopathy. No effect on the intratendinous Doppler activity could be detected, suggesting that the effect is independent of changes in blood flow. Localisation of hyperaemia appears to be the key to the pathology and for targeting the treatment. One explanation could be that the effect is obtained by destruction of nerves accompanying the vessels. PMID:16807305

  15. Evaluative Conditioning Induces Changes in Sound Valence

    PubMed Central

    Bolders, Anna C.; Band, Guido P. H.; Stallen, Pieter Jan

    2012-01-01

    Through evaluative conditioning (EC) a stimulus can acquire an affective value by pairing it with another affective stimulus. While many sounds we encounter daily have acquired an affective value over life, EC has hardly been tested in the auditory domain. To get a more complete understanding of affective processing in auditory domain we examined EC of sound. In Experiment 1 we investigated whether the affective evaluation of short environmental sounds can be changed using affective words as unconditioned stimuli (US). Congruency effects on an affective priming task for conditioned sounds demonstrated successful EC. Subjective ratings for sounds paired with negative words changed accordingly. In Experiment 2 we investigated whether extinction occurs, i.e., whether the acquired valence remains stable after repeated presentation of the conditioned sound without the US. The acquired affective value remained present, albeit weaker, even after 40 extinction trials. These results provide clear evidence for EC effects in the auditory domain. We will argue that both associative as well as propositional processes are likely to underlie these effects. PMID:22514545

  16. Sunlight-charged electrochromic battery based on hybrid film of tungsten oxide and polyaniline

    NASA Astrophysics Data System (ADS)

    Chang, Xueting; Hu, Ruirui; Sun, Shibin; Liu, Jingrong; Lei, Yanhua; Liu, Tao; Dong, Lihua; Yin, Yansheng

    2018-05-01

    Electrochromic (EC) energy storage devices that could realize the multifunctional integration of energy storage and electrochromism have gained much recent attention. Herein, an EC battery based on the hybrid film of W18O49 and polyaniline (PANI) is developed and assembled, which integrates energy storage and EC functions in one device. The W18O49/PANI-EC battery delivers a discharging capacity of 52.96 mA h g-1, which is about two times higher than that of the W18O49-EC battery. Sunlight irradiation could greatly promote the oxidation reactions of both W18O49 and PANI during the charging process of the W18O49/PANI-EC battery, thus effectively accelerating the charging rate. This work provides a green, convenient, environmentally friendly, and cost-free charging strategy for the EC energy systems and could further advance the development of the multifunctional EC devices based on the organic/inorganic composites.

  17. Spatial model of convective solute transport in brain extracellular space does not support a “glymphatic” mechanism

    PubMed Central

    Jin, Byung-Ju; Smith, Alex J.

    2016-01-01

    A “glymphatic system,” which involves convective fluid transport from para-arterial to paravenous cerebrospinal fluid through brain extracellular space (ECS), has been proposed to account for solute clearance in brain, and aquaporin-4 water channels in astrocyte endfeet may have a role in this process. Here, we investigate the major predictions of the glymphatic mechanism by modeling diffusive and convective transport in brain ECS and by solving the Navier–Stokes and convection–diffusion equations, using realistic ECS geometry for short-range transport between para-arterial and paravenous spaces. Major model parameters include para-arterial and paravenous pressures, ECS volume fraction, solute diffusion coefficient, and astrocyte foot-process water permeability. The model predicts solute accumulation and clearance from the ECS after a step change in solute concentration in para-arterial fluid. The principal and robust conclusions of the model are as follows: (a) significant convective transport requires a sustained pressure difference of several mmHg between the para-arterial and paravenous fluid and is not affected by pulsatile pressure fluctuations; (b) astrocyte endfoot water permeability does not substantially alter the rate of convective transport in ECS as the resistance to flow across endfeet is far greater than in the gaps surrounding them; and (c) diffusion (without convection) in the ECS is adequate to account for experimental transport studies in brain parenchyma. Therefore, our modeling results do not support a physiologically important role for local parenchymal convective flow in solute transport through brain ECS. PMID:27836940

  18. Spatial model of convective solute transport in brain extracellular space does not support a "glymphatic" mechanism.

    PubMed

    Jin, Byung-Ju; Smith, Alex J; Verkman, Alan S

    2016-12-01

    A "glymphatic system," which involves convective fluid transport from para-arterial to paravenous cerebrospinal fluid through brain extracellular space (ECS), has been proposed to account for solute clearance in brain, and aquaporin-4 water channels in astrocyte endfeet may have a role in this process. Here, we investigate the major predictions of the glymphatic mechanism by modeling diffusive and convective transport in brain ECS and by solving the Navier-Stokes and convection-diffusion equations, using realistic ECS geometry for short-range transport between para-arterial and paravenous spaces. Major model parameters include para-arterial and paravenous pressures, ECS volume fraction, solute diffusion coefficient, and astrocyte foot-process water permeability. The model predicts solute accumulation and clearance from the ECS after a step change in solute concentration in para-arterial fluid. The principal and robust conclusions of the model are as follows: (a) significant convective transport requires a sustained pressure difference of several mmHg between the para-arterial and paravenous fluid and is not affected by pulsatile pressure fluctuations; (b) astrocyte endfoot water permeability does not substantially alter the rate of convective transport in ECS as the resistance to flow across endfeet is far greater than in the gaps surrounding them; and (c) diffusion (without convection) in the ECS is adequate to account for experimental transport studies in brain parenchyma. Therefore, our modeling results do not support a physiologically important role for local parenchymal convective flow in solute transport through brain ECS. © 2016 Jin et al.

  19. The role of the endocannabinoid system in the brain-gut axis

    PubMed Central

    Sharkey, Keith A.; Wiley, John W.

    2016-01-01

    The actions of cannabis are mediated by receptors that are part of an endogenous cannabinoid system. The endocannabinoid system (ECS) consists of the naturally occurring ligands N-arachidonoylethanolamine (anandamide) and 2-arachidonoylglycerol (2-AG), their biosynthetic and degradative enzymes, and the cannabinoid receptors CB1 and CB2. The ECS is a widely distributed transmitter system that controls gut functions peripherally and centrally. It is an important physiologic regulator of gastrointestinal motility. Polymorphisms in the gene encoding CB1 (CNR1) have been associated with some forms of irritable bowel syndrome. The ECS is involved in the control of nausea and vomiting and visceral sensation. The homeostatic role of the ECS also extends to the control of intestinal inflammation. We review the mechanisms by which the ECS links stress and visceral pain. CB1 in sensory ganglia controls visceral sensation, and transcription of CNR1 is modified through epigenetic processes under conditions of chronic stress. These processes might link stress with abdominal pain. The ECS is also involved centrally in the manifestation of stress, and endocannabinoid signaling reduces the activity of hypothalamic–pituitary–adrenal pathways via actions in specific brain regions—notably the prefrontal cortex, amygdala, and hypothalamus. Agents that modulate the ECS are in early stages of development for treatment of gastrointestinal diseases. Increasing our understanding of the ECS will greatly advance our knowledge of interactions between the brain and gut and could lead to new treatments for gastrointestinal disorders. PMID:27133395

  20. The Role of the Endocannabinoid System in the Brain-Gut Axis.

    PubMed

    Sharkey, Keith A; Wiley, John W

    2016-08-01

    The actions of cannabis are mediated by receptors that are part of an endogenous cannabinoid system. The endocannabinoid system (ECS) consists of the naturally occurring ligands N-arachidonoylethanolamine (anandamide) and 2-arachidonoylglycerol (2-AG), their biosynthetic and degradative enzymes, and the cannabinoid (CB) receptors CB1 and CB2. The ECS is a widely distributed transmitter system that controls gut functions peripherally and centrally. It is an important physiologic regulator of gastrointestinal motility. Polymorphisms in the gene encoding CB1 (CNR1) have been associated with some forms of irritable bowel syndrome. The ECS is involved in the control of nausea and vomiting and visceral sensation. The homeostatic role of the ECS also extends to the control of intestinal inflammation. We review the mechanisms by which the ECS links stress and visceral pain. CB1 in sensory ganglia controls visceral sensation, and transcription of CNR1 is modified through epigenetic processes under conditions of chronic stress. These processes might link stress with abdominal pain. The ECS is also involved centrally in the manifestation of stress, and endocannabinoid signaling reduces the activity of hypothalamic-pituitary-adrenal pathways via actions in specific brain regions, notably the prefrontal cortex, amygdala, and hypothalamus. Agents that modulate the ECS are in early stages of development for treatment of gastrointestinal diseases. Increasing our understanding of the ECS will greatly advance our knowledge of interactions between the brain and gut and could lead to new treatments for gastrointestinal disorders. Copyright © 2016. Published by Elsevier Inc.

  1. Pregnant Women's Perspectives on Expanded Carrier Screening.

    PubMed

    Propst, Lauren; Connor, Gwendolyn; Hinton, Megan; Poorvu, Tabitha; Dungan, Jeffrey

    2018-02-23

    Expanded carrier screening (ECS) is a relatively new carrier screening option that assesses many conditions simultaneously, as opposed to traditional ethnicity-based carrier screening for a limited number of conditions. This study aimed to explore pregnant women's perspectives on ECS, including reasons for electing or declining and anxiety associated with this decision-making. A total of 80 pregnant women were surveyed from Northwestern Medicine's Clinical Genetics Division after presenting for aneuploidy screening. Of the 80 participants, 40 elected and 40 declined ECS. Trends regarding reasons for electing or declining ECS include ethnicity, desire for genetic risk information, lack of family history, perceived likelihood of being a carrier, and perceived impact on reproductive decisions. Individuals who declined ECS seemed to prefer ethnicity-based carrier screening and believed that ECS would increase their anxiety, whereas individuals who elected ECS seemed to prefer more screening and tended to believe that ECS would reduce their anxiety. These findings provide insight on decision-making with regard to ECS and can help guide interactions that genetic counselors and other healthcare providers have with patients, including assisting patients in the decision-making process.

  2. Differential activation of human T cells to allogeneic endothelial cells, epithelial cells and fibroblasts in vitro

    PubMed Central

    2012-01-01

    Background In the direct pathway, T cells recognize intact donor major histocompatability complexes and allogeneic peptide on the surface of donor antigen presenting cells (APCs). Indirect allorecognition results from the recognition of processed alloantigen by self MHC complexes on self APCs. In this study, we wished to evaluate the relative contribution of different intragraft cells to the alloactivation of nave and memory T cells though the direct and the indirect pathway of allorecognition. Methods The processing of membrane fragments from IFN-treated single donor endothelial cells (EC), fibroblasts or renal epithelial cells (RPTEC) was evaluated by DiOC labeling of each cell type and flow cytometry following interaction with PBMC. Direct pathway activation of nave CD45RA+ or memory CD45RO+ CD4+ T cells was evaluated following coculture with IFN-treated and MHC class II-expressing EC, fibroblasts or RPTEC. Indirect pathway activation was assessed using CD45RA+ or CD45RO+ CD4+ T cells cocultured with autologous irradiated APCs in the absence or presence of sonicates derived from IFN-treated allogeneic EC, fibroblasts or RPTEC. Activation of T cells was assessed by [3H]thymidine incorporation and by ELISpot assays. Results We find that CD14+ APCs readily acquire membrane fragments from fibroblasts and RPTEC, but fail to acquire membrane fragments from intact EC. However, APCs process membranes from EC undergoing apoptosis.There was a notable direct pathway alloproliferative response of CD45RO+ CD4+ T cells to IFN-treated EC, but not to fibroblasts or RPTEC. Also, there was a minimal direct pathway response of CD45RA+ CD4+ T cells to all cell types. In contrast, we found that both CD45RA+ and CD45RO+ CD4+ T cells proliferated following coculture with autologous APCs in the presence of sonicates derived from IFN-treated EC, fibroblasts or RPTEC. By ELISpot, we found that these T cells stimulated via the indirect pathway also produced the cytokines IFN, IL-2, IL-4 and IL-5. Conclusions Recipient APCs may readily process membrane fragments from allogeneic intragraft cells, but not from EC unless they are undergoing apoptosis. This processing is sufficient for indirect pathway alloactivation of both CD45RA+ and CD45RO+ CD4+ T cells. Only graft vascular EC mediate direct pathway reactivation of CD4+ T cells. PMID:23369287

  3. Cardiomyocyte exosomes regulate glycolytic flux in endothelium by direct transfer of GLUT transporters and glycolytic enzymes.

    PubMed

    Garcia, Nahuel A; Moncayo-Arlandi, Javier; Sepulveda, Pilar; Diez-Juan, Antonio

    2016-03-01

    Cardiomyocytes (CMs) and endothelial cells (ECs) have an intimate anatomical relationship, which is essential for maintaining the metabolic requirements of the heart. Little is known about the mechanisms that regulate nutrient flow from ECs to associated CMs, especially in situations of acute stress when local active processes are required to regulate endothelial transport. We examined whether CM-derived exosomes can modulate glucose transport and metabolism in ECs. In conditions of glucose deprivation, CMs increase the synthesis and secretion of exosomes. These exosomes are loaded with functional glucose transporters and glycolytic enzymes, which are internalized by ECs, leading to increased glucose uptake, glycolytic activity, and pyruvate production in recipient cells. These findings establish CM-derived exosomes as key components of the cardio-endothelial communication system which, through intercellular protein complementation, would allow a rapid response from ECs to increase glucose transport and a putative uptake of metabolic fuels from blood to CMs. This CM-EC protein complementation process might have implications for metabolic regulation in health and disease. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Neural Reactivity to Emotional Faces Mediates the Relationship Between Childhood Empathy and Adolescent Prosocial Behavior

    PubMed Central

    Flournoy, John C.; Pfeifer, Jennifer H.; Moore, William E.; Tackman, Allison; Masten, Carrie L.; Mazziotta, John C.; Iacoboni, Marco; Dapretto, Mirella

    2017-01-01

    Reactivity to others' emotions can result in empathic concern (EC), an important motivator of prosocial behavior, but can also result in personal distress (PD), which may hinder prosocial behavior. Examining neural substrates of emotional reactivity may elucidate how EC and PD differentially influence prosocial behavior. Participants (N=57) provided measures of EC, PD, prosocial behavior, and neural responses to emotional expressions at age 10 and 13. Initial EC predicted subsequent prosocial behavior. Initial EC and PD predicted subsequent reactivity to emotions in the inferior frontal gyrus (IFG) and inferior parietal lobule, respectively. Activity in the IFG, a region linked to mirror neuron processes, as well as cognitive control and language, mediated the relation between initial EC and subsequent prosocial behavior. PMID:28262939

  5. Longitudinal Associations between Executive Control and Developing Mathematical Competence in Preschool Boys and Girls

    PubMed Central

    Clark, Caron A.C.; Sheffield, Tiffany D.; Wiebe, Sandra A.; Espy, Kimberly Andrews

    2012-01-01

    Executive control (EC) is related to mathematics performance in middle childhood. However, little is known regarding how EC and informal numeracy differentially support mathematics skill acquisition in preschoolers. A sample of preschoolers (115 girls, 113 boys), stratified by social risk, completed an EC task battery at 3 years, informal numeracy assessments at 3.75 and 4.5 years, and a broad mathematics assessment during kindergarten. Strong associations were observed between latent EC at 3 and mathematics achievement in kindergarten, which remained robust after accounting for earlier informal numeracy, socio-economic status, language and processing speed. Relations between EC and mathematics achievement were stronger in girls than boys. Findings highlight the unique role of EC in predicting which children may have difficulty transitioning to formal mathematics instruction. PMID:23006040

  6. Characterizing hyporheic exchange processes using high-frequency electrical conductivity-discharge relationships on subhourly to interannual timescales

    NASA Astrophysics Data System (ADS)

    Singley, Joel G.; Wlostowski, Adam N.; Bergstrom, Anna J.; Sokol, Eric R.; Torrens, Christa L.; Jaros, Chris; Wilson, Colleen E.; Hendrickson, Patrick J.; Gooseff, Michael N.

    2017-05-01

    Concentration-discharge (C-Q) relationships are often used to quantify source water contributions and biogeochemical processes occurring within catchments, especially during discrete hydrological events. Yet, the interpretation of C-Q hysteresis is often confounded by complexity of the critical zone, such as numerous source waters and hydrochemical nonstationarity. Consequently, researchers must often ignore important runoff pathways and geochemical sources/sinks, especially the hyporheic zone because it lacks a distinct hydrochemical signature. Such simplifications limit efforts to identify processes responsible for the transience of C-Q hysteresis over time. To address these limitations, we leverage the hydrologic simplicity and long-term, high-frequency Q and electrical conductivity (EC) data from streams in the McMurdo Dry Valleys, Antarctica. In this two end-member system, EC can serve as a proxy for the concentration of solutes derived from the hyporheic zone. We utilize a novel approach to decompose loops into subhysteretic EC-Q dynamics to identify individual mechanisms governing hysteresis across a wide range of timescales. We find that hydrologic and hydraulic processes govern EC response to diel and seasonal Q variability and that the effects of hyporheic mixing processes on C-Q transience differ in short and long streams. We also observe that variable hyporheic turnover rates govern EC-Q patterns at daily to interannual timescales. Last, subhysteretic analysis reveals a period of interannual freshening of glacial meltwater streams related to the effects of unsteady flow on hyporheic exchange. The subhysteretic analysis framework we introduce may be applied more broadly to constrain the processes controlling C-Q transience and advance understanding of catchment evolution.

  7. Endocannabinoids in liver disease and hepatic encephalopathy.

    PubMed

    Magen, Iddo; Avraham, Yosefa; Berry, Elliot; Mechoulam, Raphael

    2008-01-01

    Chronic liver disease results from a variety of causes such as hepatitis virus infections, autoimmune processes and alcohol consumption. Its complications include fat deposition, hemodynamic changes and fibrosis. Clinically there may be progression to portal-hypertension and porto-systemic encephalopathy. Pioneering research from the laboratory of Kunos at NIH has stressed the importance of endocannabinoids (ECs) as mediators of some of the pathological processes in chronic liver disease. The present review summarizes the literature on the association between ECs and liver disease, as well as the therapeutic potential of ECs and exogenous cannabinoids in liver disease with emphasis on hepatic encephalopathy.

  8. Plasma functionalization of polycarbonaturethane to improve endothelialization--Effect of shear stress as a critical factor for biocompatibility control.

    PubMed

    Lukas, Karin; Thomas, Ulrich; Gessner, André; Wehner, Daniel; Schmid, Thomas; Schmid, Christof; Lehle, Karla

    2016-04-01

    Medical devices made of polycarbonaturethane (PCU) combine excellent mechanical properties and little biological degradation, but restricted hemocompatibility. Modifications of PCU might reduce platelet adhesion and promote stable endothelialization. PCU was modified using gas plasma treatment, binding of hydrogels, and coupling of cell-active molecules (modified heparin, anti-thrombin III (ATIII), argatroban, fibronectin, laminin-nonapeptide, peptides with integrin-binding arginine-glycine-aspartic acid (RGD) motif). Biocompatibility was verified with static and dynamic cell culture techniques. Blinded analysis focused on improvement in endothelial cell (EC) adhesion/proliferation, anti-thrombogenicity, reproducible manufacturing process, and shear stress tolerance of ECs. EC adhesion and antithrombogenicity were achieved with 9/35 modifications. Additionally, 6/9 stimulated EC proliferation and 3/6 modification processes were highly reproducible for endothelialization. The latter modifications comprised immobilization of ATIII (A), polyethyleneglycole-diamine-hydrogel (E) and polyethylenimine-hydrogel connected with modified heparin (IH). Under sheer stress, only the IH modification improved EC adhesion within the graft. However, ECs did not arrange in flow direction and cell anchorage was restricted. Despite large variation in surface modification chemistry and improved EC adhesion under static culture conditions, additional introduction of shear stress foiled promising preliminary data. Therefore, biocompatibility testing required not only static tests but also usage of physiological conditions such as shear stress in the case of vascular grafts. © The Author(s) 2016.

  9. The pH dependence of the cathodic peak potential of the active sites in bilirubin oxidase.

    PubMed

    Filip, Jaroslav; Tkac, Jan

    2014-04-01

    This is the first study showing pH dependence of three distinct redox sites within bilirubin oxidase (BOD) adsorbed on a nanocomposite modified electrode. The 1st redox centre with the highest redox potential Ec(1st)=404 mV vs. Ag/AgCl (614 mV vs. NHE at pH7.0) exhibited pH dependence with a slope -dEc(1st)/dpH=66(±3) mV under a non-turnover process. The 2nd redox centre with a potential Ec(2nd)=228 mV vs. Ag/AgCl (438 mV vs. NHE at pH7.0) was not dependent on pH in the absence and presence of O2. Finally, the 3rd redox site with a redox potential Ec(3rd)=92 mV vs. Ag/AgCl (302 mV vs. NHE at pH7.0) exhibited pH dependence for a cathodic process with -dEc(3rd)/dpH=70(±6) mV and for anodic process with -dEa(3rd)/dpH=73(±2) mV, respectively. Moreover, two break points for dependence of Ec(1st) or Ec(3rd) on pH were observed for the 1st (T1) site and the 3rd site assigned to involvement of two acidic amino acids (Asp105 and Glu463). A diagram of a potential difference between cathodic peaks of BOD as a dependence on pH is shown. The results obtained can be of interest for construction of biofuel cells based on BOD such as for generation of a low level of electricity from body fluids. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Visual gene-network analysis reveals the cancer gene co-expression in human endometrial cancer

    PubMed Central

    2014-01-01

    Background Endometrial cancers (ECs) are the most common form of gynecologic malignancy. Recent studies have reported that ECs reveal distinct markers for molecular pathogenesis, which in turn is linked to the various histological types of ECs. To understand further the molecular events contributing to ECs and endometrial tumorigenesis in general, a more precise identification of cancer-associated molecules and signaling networks would be useful for the detection and monitoring of malignancy, improving clinical cancer therapy, and personalization of treatments. Results ECs-specific gene co-expression networks were constructed by differential expression analysis and weighted gene co-expression network analysis (WGCNA). Important pathways and putative cancer hub genes contribution to tumorigenesis of ECs were identified. An elastic-net regularized classification model was built using the cancer hub gene signatures to predict the phenotypic characteristics of ECs. The 19 cancer hub gene signatures had high predictive power to distinguish among three key principal features of ECs: grade, type, and stage. Intriguingly, these hub gene networks seem to contribute to ECs progression and malignancy via cell-cycle regulation, antigen processing and the citric acid (TCA) cycle. Conclusions The results of this study provide a powerful biomarker discovery platform to better understand the progression of ECs and to uncover potential therapeutic targets in the treatment of ECs. This information might lead to improved monitoring of ECs and resulting improvement of treatment of ECs, the 4th most common of cancer in women. PMID:24758163

  11. Optimized human platelet lysate as novel basis for a serum-, xeno-, and additive-free corneal endothelial cell and tissue culture.

    PubMed

    Thieme, Daniel; Reuland, Lynn; Lindl, Toni; Kruse, Friedrich; Fuchsluger, Thomas

    2018-02-01

    The expansion of donor-derived corneal endothelial cells (ECs) is a promising approach for regenerative therapies in corneal diseases. To achieve the best Good Manufacturing Practice standard the entire cultivation process should be devoid of nonhuman components. However, so far, there is no suitable xeno-free protocol for clinical applications. We therefore introduce a processed variant of a platelet lysate for the use in corneal cell and tissue culture based on a Good Manufacturing Practice-grade thrombocyte concentrate. This processed human platelet lysate (phPL), free of any animal components and of anticoagulants such as heparin with a physiological ionic composition, was used to cultivate corneal ECs in vitro and ex vivo in comparison to standard cultivation with fetal calf serum (FCS). Human donor corneas were cut in quarters while 2 quarters of each cornea were incubated with the respective medium supplement. Three fields of view per quarter were taken into account for the analysis. Evaluation of phPL as a medium supplement in cell culture of immortalized EC showed a superior viability compared with FCS control with reduced cell proliferation. Furthermore, the viability during the expansion of primary cells is significantly (3-fold ±0.5) increased with phPL compared with FCS standard medium. Quartering donor corneas was traumatic for the endothelium and therefore resulted in increased EC loss. Interestingly, however, cultivation of the quartered pieces for 2 weeks in 0.1-mg/ml pHPL in Biochrome I showed a 21 (±10) % EC loss compared with 67 (±12) % EC loss when cultivated in 2% FCS in Biochrome I. The cell culture protocol with pHPL as FCS replacement seems to be superior to the standard FCS protocols with respect to EC survival. It offers a xeno-free and physiological environment for corneal endothelial cells. This alternative cultivation protocol could facilitate the use of EC for human corneal cell therapy. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Nitrogen removal from the saline sludge liquor by electrochemical denitrification.

    PubMed

    Xie, Z M; Li, X Y; Chan, K Y

    2006-01-01

    Sludge liquor from the sludge dewatering process has a high ammonia content. In the present study, a lab-scale electrochemical (EC) system with a pair of Ti electrode plates was used for treating the sludge centrate liquor of digested wastewater sludge with a NH4(+) - N content of around 500 mg/L. The sludge liquor had a high salinity due to seawater being used for toilet flushing in Hong Kong. The results show that the EC process is highly effective for denitrification of the saline sludge liquor. Complete nitrogen removal could be achieved within 1 hr or so. The rate of EC denitrification increased with the current intensity applied. The best current efficiency for nitrogen removal was obtained for a gap distance between the electrodes at 8 mm. Electro-chlorination was considered to be the major mechanism of EC denitrification. The formation of chlorination by-products (CBPs) appeared to be minimal with the total trihalomethanes (THM) detected at a level of 300 microg/L or lower. The power consumption for EC denitrification was around 23 kWh/kg N. Additional electro-flocculation with a pair of iron needle electrodes could enhance the flocculation and subsequent sedimentation of colloidal organics in the sludge liquor, increasing the organic removal from less than 30% to more than 70%. Therefore, the EC process including both electro-denitrification and electro-flocculation can be developed as the most cost-effective method for treatment of the saline sludge liquor.

  13. Electrochemical CO2 and O2 separation for crew and plant environments

    NASA Technical Reports Server (NTRS)

    Lee, M. G.; Grigger, David J.; Foerg, Sandra L.

    1992-01-01

    The study describes a closed ecosystem concept that includes electrochemical CO2 and O2 separators and a moisture condenser/separator for maintaining CO2, O2, and humidity levels in the crew and plant habitats at their respective optimal conditions. The key processes of this concept are aqueous electrolyte-based electrochemical CO2 and O2 separations. The principles and cell characteristics of these electrochemical gas separation processes are described. Also presented are descriptions of test hardware and the test results of the Electrochemical CO2 Separator (ECS) and the Electrochemical O2 Separator (EOS), and the combination of the ECS and the EOS. The test results proved that the ECS and EOS processes for the combined concept are viable.

  14. eddy4R 0.2.0: a DevOps model for community-extensible processing and analysis of eddy-covariance data based on R, Git, Docker, and HDF5

    NASA Astrophysics Data System (ADS)

    Metzger, Stefan; Durden, David; Sturtevant, Cove; Luo, Hongyan; Pingintha-Durden, Natchaya; Sachs, Torsten; Serafimovich, Andrei; Hartmann, Jörg; Li, Jiahong; Xu, Ke; Desai, Ankur R.

    2017-08-01

    Large differences in instrumentation, site setup, data format, and operating system stymie the adoption of a universal computational environment for processing and analyzing eddy-covariance (EC) data. This results in limited software applicability and extensibility in addition to often substantial inconsistencies in flux estimates. Addressing these concerns, this paper presents the systematic development of portable, reproducible, and extensible EC software achieved by adopting a development and systems operation (DevOps) approach. This software development model is used for the creation of the eddy4R family of EC code packages in the open-source R language for statistical computing. These packages are community developed, iterated via the Git distributed version control system, and wrapped into a portable and reproducible Docker filesystem that is independent of the underlying host operating system. The HDF5 hierarchical data format then provides a streamlined mechanism for highly compressed and fully self-documented data ingest and output. The usefulness of the DevOps approach was evaluated for three test applications. First, the resultant EC processing software was used to analyze standard flux tower data from the first EC instruments installed at a National Ecological Observatory (NEON) field site. Second, through an aircraft test application, we demonstrate the modular extensibility of eddy4R to analyze EC data from other platforms. Third, an intercomparison with commercial-grade software showed excellent agreement (R2 = 1.0 for CO2 flux). In conjunction with this study, a Docker image containing the first two eddy4R packages and an executable example workflow, as well as first NEON EC data products are released publicly. We conclude by describing the work remaining to arrive at the automated generation of science-grade EC fluxes and benefits to the science community at large. This software development model is applicable beyond EC and more generally builds the capacity to deploy complex algorithms developed by scientists in an efficient and scalable manner. In addition, modularity permits meeting project milestones while retaining extensibility with time.

  15. Disentangling the Role of the MEC and LEC in the Processing of Spatial and Non-Spatial Information: Contribution of Lesion Studies

    PubMed Central

    Save, Etienne; Sargolini, Francesca

    2017-01-01

    It is now widely accepted that the entorhinal cortex (EC) plays a pivotal role in the processing of spatial information and episodic memory. The EC is segregated into two sub-regions, the medial EC (MEC) and the lateral EC (LEC) but a comprehensive understanding of their roles across multiple behavioral contexts remains unclear. Considering that it is still useful to investigate the impact of lesions of EC on behavior, we review the contribution of lesion approach to our knowledge of EC functions. We show that the MEC and LEC play different roles in the processing of spatial and non-spatial information. The MEC is necessary to the use of distal but not proximal landmarks during navigation and is crucial for path integration, in particular integration of linear movements. Consistent with predominant hypothesis, the LEC is important for combining the spatial and non-spatial aspects of the environment. However, object exploration studies suggest that the functional segregation between the MEC and the LEC is not as clearly delineated and is dependent on environmental and behavioral factors. Manipulation of environmental complexity and therefore of cognitive demand shows that the MEC and the LEC are not strictly necessary to the processing of spatial and non-spatial information. In addition we suggest that the involvement of these sub-regions can depend on the kind of behavior, i.e., navigation or exploration, exhibited by the animals. Thus, the MEC and the LEC work in a flexible manner to integrate the “what” and “where” information in episodic memory upstream the hippocampus. PMID:29163076

  16. Understanding performance limitation and suppression of leakage current or self-discharge in electrochemical capacitors: a review.

    PubMed

    Ike, Innocent S; Sigalas, Iakovos; Iyuke, Sunny

    2016-01-14

    Self-discharge is known to have considerable adverse effects on the performance and application of electrochemical capacitors (ECs). Thus, obtaining an understanding of EC self-discharge mechanism(s) and subsequent derivation and solution of EC models, subject to a particular mechanism or combination of mechanisms during charging, discharging and storage of the device, is the only way to solve problems associated with EC self-discharge. In this review, we summarize recent progress with respect to EC self-discharge by considering the two basic types, electric double-layer capacitors (EDLC) and pseudocapacitors, and their hybrids with their respective charge storage mechanisms, distinguishable self-discharge mechanisms, charge redistribution and charge/energy loss during self-discharge. It was clearly observed that most of the voltage reduction is not purely due to the self-discharge effect but is basically due to redistribution of charge carriers deep inside pores and can therefore be retrieved from a capacitor during long-time discharging. Tuning the self-discharge rate is therefore feasible for single-walled carbon nanotube (SWNT) ECs and can be achieved by simply adjusting the surface chemistry of the nanotubes. The effects of surface chemistry modification on EC self-discharge are very important in studying and suppressing the self-discharge process and will benefit potential applications of ECs with respect to energy retention. Self-discharge can be averted by the use of redox couples that are transformed to insoluble species via electrolysis and adsorbed onto the activated carbon electrode in redox-couple EDLCs, thus transforming the EDLC electrolyte into a material that can store charge. Self-discharge in ECs can also be successfully suppressed by utilizing an ion-interchange layer (ion-exchange membrane), separator or CuSO4 mobile electrolyte that can be converted into an insoluble species by electrolysis during the charge/discharge process. This will help in producing a modern-day blueprint for ECs with high capacitance and improved energy sustainability.

  17. Cognitive testing with female nutrition and education assistance program participants informs validity of the Satter eating competence inventory.

    PubMed

    Krall, Jodi Stotts; Lohse, Barbara

    2010-01-01

    Examine the validity of a self-report measure of eating competence with low-income women. Twenty-five females (18-49 years old) recruited from low-income venues in Pennsylvania completed cognitive testing through an iterative interview process. Respondents' oral responses were compared to researchers' intended meaning of ecSatter Inventory (ecSI) items; responses were mapped to evaluate the similarity between respondents' internally generated answers and their ecSI choices for survey items; and scored responses were compared among participants. Interview findings provided a rationale for modifying the ecSI prior to use with low-income women. Four items were misinterpreted for various reasons, including problems with clarity and wording. The modified ecSI, termed the ecSatter Inventory for Low-Income (ecSI/LI), was comprehended as intended by researchers. Congruence of cognitive responses and ecS/LI scores further supported the instrument's validity. Cognitive testing resulted in the development of an instrument to measure eating competence in low-income adults. The ecSI/LI requires validation with a large, heterogeneous low-income sample. Copyright 2010 Society for Nutrition Education. Published by Elsevier Inc. All rights reserved.

  18. Emerging contaminants in surface waters in China—a short review

    NASA Astrophysics Data System (ADS)

    Yang, Guang; Fan, Maohong; Zhang, Guangming

    2014-07-01

    Emerging contaminants (ECs) have drawn attention to many countries due to their persistent input and potential threat to human health and the environment. This article reviews the current contamination sources and their status for surface waters in China. The contamination levels of ECs in surface waters are in the range ng L-1 to μg L-1 in China, apparently about the same as the situation in other countries. ECs enter surface water via runoff, drainage, rainfall, and wastewater treatment effluent. The frequency of occurrence of ECs increased rapidly from 2006 to 2011; a significant reason is the production and consumption of pharmaceuticals and personal care products. As for the distribution of EC pollution in China, the frequency of occurrence of ECs in eastern regions is higher than in western regions. A majority of EC studies have focused on surface waters of the Haihe River and Pearl River watersheds due to their highly developed industries and intense human activity. Legislative and administrative regulation of ECs is lacking in China. To remove ECs, a number of technologies, such as absorption by activated carbon, membrane filtration technology, and advanced oxidation processes, have been researched.

  19. Adopted Individuals' Views on the Utility and Value of Expanded Carrier Screening.

    PubMed

    Spencer, Sara; Ewing, Sarah; Calcagno, Kathryn; O'Neill, Suzanne

    2018-03-30

    Adoptees may not have family medical history and ethnicity information. Carrier screening assesses reproductive risk. Expanded carrier screening (ECS) screens for many genetic conditions regardless of a patient's knowledge of family history and ethnicity. This study aimed to better understand the opinions and attitudes of adopted individuals on the use of ECS in determining a patient's reproductive genetic risks. Specifically, the study assessed how adopted individuals feel that results of ECS may be useful to them and whether adoptees feel that meeting with a genetics professional in the process of undergoing ECS would be useful. Adult adoptees (N = 124) were recruited online. Their opinions on ECS were explored. The majority reported they had never been offered carrier screening (92%). The majority of adoptees wanted ECS (76%). Neither the amount of contact with biological relatives nor having medical knowledge about biological relatives was significantly associated with adoptees' desire to pursue ECS. There was a significant positive correlation between adoptees of higher education levels and the amount they would pay for ECS (p = 0.004). The majority of participants (95%) indicated a genetics professional would be helpful when undergoing ECS. The findings suggest this population may want ECS and support from genetics healthcare professionals. Advocacy for genetic counseling and testing for adoptees appears justifiable.

  20. A Contact-Based Method for Differentiation of Human Mesenchymal Stem Cells into an Endothelial Cell-Phenotype.

    PubMed

    Joddar, Binata; Kumar, Shweta Anil; Kumar, Alok

    2018-06-01

    Adult stem cells such as mesenchymal stem cells (MSC) are known to possess the ability to augment neovascularization processes and are thus widely popular as an autologous source of progenitor cells. However there is a huge gap in our current knowledge of mechanisms involved in differentiating MSC into endothelial cells (EC), essential for lining engineered blood vessels. To fill up this gap, we attempted to differentiate human MSC into EC, by culturing the former onto chemically fixed layers of EC or its ECM, respectively. We expected direct contact of MSC when cultured atop fixed EC or its ECM, would coax the former to differentiate into EC. Results showed that human MSC cultured atop chemically fixed EC or its ECM using EC-medium showed enhanced expression of CD31, a marker for EC, compared to other cases. Further in all human MSC cultured using EC-medium, typically characteristic cobble stone shaped morphologies were noted in comparison to cells cultured using MSC medium, implying that the differentiated cells were sensitive to soluble VEGF supplementation present in the EC-medium. Results will enhance and affect therapies utilizing autologous MSC as a cell source for generating vascular cells to be used in a variety of tissue engineering applications.

  1. The Endocannabinoid System and Spermatogenesis

    PubMed Central

    Grimaldi, Paola; Di Giacomo, Daniele; Geremia, Raffaele

    2013-01-01

    Spermatogenesis is a complex process in which male germ cells undergo a mitotic phase followed by meiosis and by a morphogenetic process to form mature spermatozoa. Spermatogenesis is under the control of gonadotropins, steroid hormones and it is modulated by a complex network of autocrine and paracrine factors. These modulators ensure the correct progression of germ cell differentiation to form mature spermatozoa. Recently, it has been pointed out the relevance of endocannabinoids as critical modulators of male reproduction. Endocannabinoids are natural lipids able to bind to cannabinoid receptors and whose levels are regulated by specific biosynthetic and degradative enzymes. Together with their receptors and metabolic enzymes, they form the “endocannabinoid system” (ECS). In male reproductive tracts, they affect Sertoli cell activities, Leydig cell proliferation, germ cell differentiation, sperm motility, capacitation, and acrosome reaction. The ECS interferes with the pituitary-gonadal axis, and an intricate crosstalk between ECS and steroid hormones has been highlighted. This mini-review will focus on the involvement of the ECS in the control of spermatogenesis and on the interaction between ECS and steroid hormones. PMID:24379805

  2. Formation of ethyl carbamate and changes during fermentation and storage of yellow rice wine.

    PubMed

    Wu, Pinggu; Cai, Chenggang; Shen, Xianghong; Wang, Liyuan; Zhang, Jing; Tan, Ying; Jiang, Wei; Pan, Xiaodong

    2014-01-01

    Ethyl carbamate (EC) was analyzed during yellow rice wine production and storage. EC increased slowly during fermentation and rapidly after frying and sterilization. Less amount of EC was formed when cooled rapidly to 30 °C than when cooled naturally. High temperature and long storage time increased EC formation. After 400 days storage, EC increased from 74.0 to 84.2, 131.8 and 509.4 μg/kg at 4 °C, room temperature and 37 °C, respectively, and there was significantly difference between the fried wine and the wine on sale from 2011 (p<0.01). Urea increased during yellow rice wine fermentation and was above 20 mg/kg after the wine was fried; urea contributed to EC formation when the fried wine was cooled slowly. These results indicate that it is necessary for industry to optimize the wine frying conditions, such as temperature, time and cooling process in order to decrease EC formation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Plant lesions promote the rapid multiplication of Escherichia coli O157:H7 on post-harvest lettuce

    USDA-ARS?s Scientific Manuscript database

    Several outbreaks of Escherichia coli O157:H7 (EcO157) infections have been associated with minimally processed leafy vegetables in the U.S. Harvesting and processing cause plant tissue damage. In order to assess the role of plant tissue damage in the contamination of leafy greens with EcO157, the e...

  4. Endothelial cells promote the proliferation of lymphocytes partly through the Wnt pathway via LEF-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Shu-Hong; Nan, Ke-Jun, E-mail: nankj@163.com; Wang, Yao-Chun

    The function of T cells and B cells is to recognize specific 'non-self' antigens, during a process known as antigen presentation. Once they have identified an invader, the cells generate specific responses that are tailored to maximally eliminate specific pathogens or pathogen-infected cells. Endothelial cells (ECs) can trigger the activation of T cells through their class I and class II MHC molecules. In this study, we examined the effect of ECs on the proliferation of lymphocytes. We report that the proliferation of T and B cells can be improved by interaction with ECs. LEF-1 is one of the main molecularmore » mediators in this process, and the inhibition of LEF-1 induces apoptosis. These results suggest that LEF-1 modulates positively the proliferation of lymphocytes induced by their interaction with ECs.« less

  5. Treatment of cooling tower blowdown water containing silica, calcium and magnesium by electrocoagulation.

    PubMed

    Liao, Z; Gu, Z; Schulz, M C; Davis, J R; Baygents, J C; Farrell, J

    2009-01-01

    This research investigated the effectiveness of electrocoagulation using iron and aluminium electrodes for treating cooling tower blowdown (CTB) waters containing dissolved silica (Si(OH)(4)), Ca(2 + ) and Mg(2 + ). The removal of each target species was measured as a function of the coagulant dose in simulated CTB waters with initial pH values of 5, 7, and 9. Experiments were also performed to investigate the effect of antiscaling compounds and coagulation aids on hardness ion removal. Both iron and aluminum electrodes were effective at removing dissolved silica. For coagulant doses < or =3 mM, silica removal was a linear function of the coagulant dose, with 0.4 to 0.5 moles of silica removed per mole of iron or aluminium. Iron electrodes were only 30% as effective at removing Ca(2 + ) and Mg(2 + ) as compared to silica. There was no measurable removal of hardness ions by aluminium electrodes in the absence of organic additives. Phosphonate based antiscaling compounds were uniformly effective at increasing the removal of Ca(2 + ) and Mg(2 + ) by both iron and aluminium electrodes. Cationic and amphoteric polymers used as coagulation aids were also effective at increasing hardness ion removal.

  6. Optimization of the pretreatment of wastewater from a slaughterhouse and packing plant through electrocoagulation in a batch reactor.

    PubMed

    Orssatto, Fábio; Ferreira Tavares, Maria Hermínia; Manente da Silva, Flávia; Eyng, Eduardo; Farias Biassi, Brendown; Fleck, Leandro

    2017-10-01

    The purpose of this study is to evaluate the removal of chemical oxygen demand (COD), turbidity and color of wastewater from a pig slaughterhouse and packing plant through the electrochemical technique and to optimize the ΔV (electric potential difference) and HRT (hydraulic retention time) variables in an electrocoagulation batch reactor using aluminum electrodes. The experimental design used was rotatable central composite design. For turbidity, the values for removal efficiency obtained varied from 92.85% to 99.28%; for color, they varied from 81.34% to 98.93% and for COD, they varied from 58.61% to 81.01%. The best optimized conditions of treatment were at 25 min for the HRT and 25 V for the ΔV, which correspond to electrical current of 1.08 A and a current density of 21.6 mA cm -2 . The aluminum residue varied from 15.254 to 54.291 mg L -1 and the cost of the treatment was US$4.288 m -3 . The novelty of the work was the simultaneous optimization of three response variables using the desirability function applied to the treatment of wastewater from slaughterhouses.

  7. Neural Reactivity to Emotional Faces May Mediate the Relationship Between Childhood Empathy and Adolescent Prosocial Behavior.

    PubMed

    Flournoy, John C; Pfeifer, Jennifer H; Moore, William E; Tackman, Allison M; Masten, Carrie L; Mazziotta, John C; Iacoboni, Marco; Dapretto, Mirella

    2016-11-01

    Reactivity to others' emotions not only can result in empathic concern (EC), an important motivator of prosocial behavior, but can also result in personal distress (PD), which may hinder prosocial behavior. Examining neural substrates of emotional reactivity may elucidate how EC and PD differentially influence prosocial behavior. Participants (N = 57) provided measures of EC, PD, prosocial behavior, and neural responses to emotional expressions at ages 10 and 13. Initial EC predicted subsequent prosocial behavior. Initial EC and PD predicted subsequent reactivity to emotions in the inferior frontal gyrus (IFG) and inferior parietal lobule, respectively. Activity in the IFG, a region linked to mirror neuron processes, as well as cognitive control and language, mediated the relation between initial EC and subsequent prosocial behavior. © 2016 The Authors. Child Development © 2016 Society for Research in Child Development, Inc.

  8. Evaluating the convergence between eddy-covariance and biometric methods for assessing carbon budgets of forests.

    PubMed

    Campioli, M; Malhi, Y; Vicca, S; Luyssaert, S; Papale, D; Peñuelas, J; Reichstein, M; Migliavacca, M; Arain, M A; Janssens, I A

    2016-12-14

    The eddy-covariance (EC) micro-meteorological technique and the ecology-based biometric methods (BM) are the primary methodologies to quantify CO 2 exchange between terrestrial ecosystems and the atmosphere (net ecosystem production, NEP) and its two components, ecosystem respiration and gross primary production. Here we show that EC and BM provide different estimates of NEP, but comparable ecosystem respiration and gross primary production for forest ecosystems globally. Discrepancies between methods are not related to environmental or stand variables, but are consistently more pronounced for boreal forests where carbon fluxes are smaller. BM estimates are prone to underestimation of net primary production and overestimation of leaf respiration. EC biases are not apparent across sites, suggesting the effectiveness of standard post-processing procedures. Our results increase confidence in EC, show in which conditions EC and BM estimates can be integrated, and which methodological aspects can improve the convergence between EC and BM.

  9. Evaluating the convergence between eddy-covariance and biometric methods for assessing carbon budgets of forests

    NASA Astrophysics Data System (ADS)

    Campioli, M.; Malhi, Y.; Vicca, S.; Luyssaert, S.; Papale, D.; Peñuelas, J.; Reichstein, M.; Migliavacca, M.; Arain, M. A.; Janssens, I. A.

    2016-12-01

    The eddy-covariance (EC) micro-meteorological technique and the ecology-based biometric methods (BM) are the primary methodologies to quantify CO2 exchange between terrestrial ecosystems and the atmosphere (net ecosystem production, NEP) and its two components, ecosystem respiration and gross primary production. Here we show that EC and BM provide different estimates of NEP, but comparable ecosystem respiration and gross primary production for forest ecosystems globally. Discrepancies between methods are not related to environmental or stand variables, but are consistently more pronounced for boreal forests where carbon fluxes are smaller. BM estimates are prone to underestimation of net primary production and overestimation of leaf respiration. EC biases are not apparent across sites, suggesting the effectiveness of standard post-processing procedures. Our results increase confidence in EC, show in which conditions EC and BM estimates can be integrated, and which methodological aspects can improve the convergence between EC and BM.

  10. Evaluating the convergence between eddy-covariance and biometric methods for assessing carbon budgets of forests

    PubMed Central

    Campioli, M.; Malhi, Y.; Vicca, S.; Luyssaert, S.; Papale, D.; Peñuelas, J.; Reichstein, M.; Migliavacca, M.; Arain, M. A.; Janssens, I. A.

    2016-01-01

    The eddy-covariance (EC) micro-meteorological technique and the ecology-based biometric methods (BM) are the primary methodologies to quantify CO2 exchange between terrestrial ecosystems and the atmosphere (net ecosystem production, NEP) and its two components, ecosystem respiration and gross primary production. Here we show that EC and BM provide different estimates of NEP, but comparable ecosystem respiration and gross primary production for forest ecosystems globally. Discrepancies between methods are not related to environmental or stand variables, but are consistently more pronounced for boreal forests where carbon fluxes are smaller. BM estimates are prone to underestimation of net primary production and overestimation of leaf respiration. EC biases are not apparent across sites, suggesting the effectiveness of standard post-processing procedures. Our results increase confidence in EC, show in which conditions EC and BM estimates can be integrated, and which methodological aspects can improve the convergence between EC and BM. PMID:27966534

  11. Fibrinogen Reduction During Selective Plasma Exchange due to Membrane Fouling.

    PubMed

    Ohkubo, Atsushi; Okado, Tomokazu; Miyamoto, Satoko; Hashimoto, Yurie; Komori, Shigeto; Yamamoto, Motoki; Maeda, Takuma; Itagaki, Ayako; Yamamoto, Hiroko; Seshima, Hiroshi; Kurashima, Naoki; Iimori, Soichiro; Naito, Shotaro; Sohara, Eisei; Uchida, Shinichi; Rai, Tatemitsu

    2017-06-01

    Fibrinogen is substantially reduced by most plasmapheresis modalities but retained in selective plasma exchange using Evacure EC-4A10 (EC-4A). Although EC-4A's fibrinogen sieving coefficient is 0, a session of selective plasma exchange reduced fibrinogen by approximately 19%. Here, we investigated sieving coefficient in five patients. When the mean processed plasma volume was 1.15 × plasma volume, the mean reduction of fibrinogen during selective plasma exchange was approximately 15%. Fibrinogen sieving coefficient was 0 when the processed plasma volume was 1.0 L, increasing to 0.07 when the processed plasma volume was 3.0 L, with a mean of 0.03 during selective plasma exchange. When fibrinogen sieving coefficient was 0, selective plasma exchange reduced fibrinogen by approximately 10%. Scanning electron microscopy images revealed internal fouling of EC-4A's hollow fiber membrane by substances such as fibrinogen fibrils. Thus, fibrinogen reduction by selective plasma exchange may be predominantly caused by membrane fouling rather than filtration. © 2017 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  12. Azo dyes wastewater treatment and simultaneous electricity generation in a novel process of electrolysis cell combined with microbial fuel cell.

    PubMed

    Zou, Haiming; Wang, Yan

    2017-07-01

    A new process of electrolysis cell (EC) coupled with microbial fuel cell (MFC) was developed here and its feasibility in methyl red (MR) wastewater treatment and simultaneous electricity generation was assessed. Results indicate that an excellent MR removal and electricity production performance was achieved, where the decolorization and COD removal efficiencies were 100% and 89.3%, respectively and a 0.56V of cell voltage output was generated. Electrolysis voltage showed a positive influence on decolorization rate (DR) but also cause a rapid decrease in current efficiency (CE). Although a low COD removal rate of 38.5% was found in EC system, biodegradability of MR solution was significantly enhanced, where the averaged DR was 85.6%. Importantly, COD removal rate in EC-MFC integrated process had a 50.8% improvement compared with the single EC system. The results obtained here would be beneficial to provide a prospective alternative for azo dyes wastewater treatment and power production. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Laboratory Experiments on the Electrochemical Remediation of Environment. Part 4: Color Removal of Simulated Wastewater by Electrocoagulation-Electroflotation

    NASA Astrophysics Data System (ADS)

    Ibanez, Jorge G.; Singh, M. M.; Szafran, Z.

    1998-08-01

    Due to the large production of aqueous waste streams from textile mills and dye production plants, several processes have been under intense study. Electrochemical processes offer some distinctive advantages, including effects due to: 1) the production of electrolysis gases, and 2) the production of polyvalent cations from the oxidation of corrodible anodes (like Fe and Al). The gas bubbles can carry the pollutant to the top of the solution where it can be more easily concentrated, collected and removed. The metallic ions can react with the OH- ions produced at the cathode during the evolution of H2 gas to yield insoluble hydroxides that will adsorb pollutants out of the solution and also contribute to coagulation by neutralizing any negatively charged colloidal particles that might be present. In this experiment an iron electrode (paper clip) is used in conjunction with pH indicator dyes, so dramatic color changes will be noticed.

  14. The development and malleability of executive control abilities

    PubMed Central

    Hsu, Nina S.; Novick, Jared M.; Jaeggi, Susanne M.

    2014-01-01

    Executive control (EC) generally refers to the regulation of mental activity. It plays a crucial role in complex cognition, and EC skills predict high-level abilities including language processing, memory, and problem solving, as well as practically relevant outcomes such as scholastic achievement. EC develops relatively late in ontogeny, and many sub-groups of developmental populations demonstrate an exaggeratedly poor ability to control cognition even alongside the normal protracted growth of EC skills. Given the value of EC to human performance, researchers have sought means to improve it through targeted training; indeed, accumulating evidence suggests that regulatory processes are malleable through experience and practice. Nonetheless, there is a need to understand both whether specific populations might particularly benefit from training, and what cortical mechanisms engage during performance of the tasks used in the training protocols. This contribution has two parts: in Part I, we review EC development and intervention work in select populations. Although promising, the mixed results in this early field make it difficult to draw strong conclusions. To guide future studies, in Part II, we discuss training studies that have included a neuroimaging component – a relatively new enterprise that also has not yet yielded a consistent pattern of results post-training, preventing broad conclusions. We therefore suggest that recent developments in neuroimaging (e.g., multivariate and connectivity approaches) may be useful to advance our understanding of the neural mechanisms underlying the malleability of EC and brain plasticity. In conjunction with behavioral data, these methods may further inform our understanding of the brain–behavior relationship and the extent to which EC is dynamic and malleable, guiding the development of future, targeted interventions to promote executive functioning in both healthy and atypical populations. PMID:25071485

  15. On the Emergent Constraints of Climate Sensitivity [On proposed emergent constraints of climate sensitivity

    DOE PAGES

    Qu, Xin; Hall, Alex; DeAngelis, Anthony M.; ...

    2018-01-11

    Differences among climate models in equilibrium climate sensitivity (ECS; the equilibrium surface temperature response to a doubling of atmospheric CO2) remain a significant barrier to the accurate assessment of societally important impacts of climate change. Relationships between ECS and observable metrics of the current climate in model ensembles, so-called emergent constraints, have been used to constrain ECS. Here a statistical method (including a backward selection process) is employed to achieve a better statistical understanding of the connections between four recently proposed emergent constraint metrics and individual feedbacks influencing ECS. The relationship between each metric and ECS is largely attributable tomore » a statistical connection with shortwave low cloud feedback, the leading cause of intermodel ECS spread. This result bolsters confidence in some of the metrics, which had assumed such a connection in the first place. Additional analysis is conducted with a few thousand artificial metrics that are randomly generated but are well correlated with ECS. The relationships between the contrived metrics and ECS can also be linked statistically to shortwave cloud feedback. Thus, any proposed or forthcoming ECS constraint based on the current generation of climate models should be viewed as a potential constraint on shortwave cloud feedback, and physical links with that feedback should be investigated to verify that the constraint is real. Additionally, any proposed ECS constraint should not be taken at face value since other factors influencing ECS besides shortwave cloud feedback could be systematically biased in the models.« less

  16. On the Emergent Constraints of Climate Sensitivity [On proposed emergent constraints of climate sensitivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qu, Xin; Hall, Alex; DeAngelis, Anthony M.

    Differences among climate models in equilibrium climate sensitivity (ECS; the equilibrium surface temperature response to a doubling of atmospheric CO2) remain a significant barrier to the accurate assessment of societally important impacts of climate change. Relationships between ECS and observable metrics of the current climate in model ensembles, so-called emergent constraints, have been used to constrain ECS. Here a statistical method (including a backward selection process) is employed to achieve a better statistical understanding of the connections between four recently proposed emergent constraint metrics and individual feedbacks influencing ECS. The relationship between each metric and ECS is largely attributable tomore » a statistical connection with shortwave low cloud feedback, the leading cause of intermodel ECS spread. This result bolsters confidence in some of the metrics, which had assumed such a connection in the first place. Additional analysis is conducted with a few thousand artificial metrics that are randomly generated but are well correlated with ECS. The relationships between the contrived metrics and ECS can also be linked statistically to shortwave cloud feedback. Thus, any proposed or forthcoming ECS constraint based on the current generation of climate models should be viewed as a potential constraint on shortwave cloud feedback, and physical links with that feedback should be investigated to verify that the constraint is real. Additionally, any proposed ECS constraint should not be taken at face value since other factors influencing ECS besides shortwave cloud feedback could be systematically biased in the models.« less

  17. Akt Suppression of TGFβ Signaling Contributes to the Maintenance of Vascular Identity in Embryonic Stem Cell-Derived Endothelial Cells

    PubMed Central

    Israely, Edo; Ginsberg, Michael; Nolan, Daniel; Ding, Bi-Sen; James, Daylon; Elemento, Olivier; Rafii, Shahin; Rabbany, Sina Y

    2016-01-01

    The ability to generate and maintain stable in vitro cultures of mouse endothelial cells (EC) has great potential for genetic dissection of the numerous pathologies involving vascular dysfunction as well as therapeutic applications. However, previous efforts at achieving sustained cultures of primary stable murine vascular cells have fallen short, and the cellular requirements for EC maintenance in vitro remain undefined. In this study, we have generated vascular ECs from mouse embryonic stem (ES) cells, and show that active Akt is essential to their survival and propagation as homogeneous monolayers in vitro. These cells harbor the phenotypical, biochemical, and functional characteristics of ECs, and expand throughout long-term cultures, while maintaining their angiogenic capacity. Moreover, Akt-transduced embryonic ECs form functional perfused vessels in vivo that anastomose with host blood vessels. We provide evidence for a novel function of Akt in stabilizing EC identity, whereby the activated form of the protein protects mouse ES cell-derived ECs from TGFβ-mediated transdifferentiation by downregulating SMAD3. These findings identify a role for Akt in regulating the developmental potential of ES cell-derived ECs, and demonstrate that active Akt maintains endothelial identity in embryonic ECs by interfering with active TGFβ-mediated processes that would ordinarily usher these cells to alternate fates. PMID:23963623

  18. Akt suppression of TGFβ signaling contributes to the maintenance of vascular identity in embryonic stem cell-derived endothelial cells.

    PubMed

    Israely, Edo; Ginsberg, Michael; Nolan, Daniel; Ding, Bi-Sen; James, Daylon; Elemento, Olivier; Rafii, Shahin; Rabbany, Sina Y

    2014-01-01

    The ability to generate and maintain stable in vitro cultures of mouse endothelial cells (ECs) has great potential for genetic dissection of the numerous pathologies involving vascular dysfunction as well as therapeutic applications. However, previous efforts at achieving sustained cultures of primary stable murine vascular cells have fallen short, and the cellular requirements for EC maintenance in vitro remain undefined. In this study, we have generated vascular ECs from mouse embryonic stem (ES) cells and show that active Akt is essential to their survival and propagation as homogeneous monolayers in vitro. These cells harbor the phenotypical, biochemical, and functional characteristics of ECs and expand throughout long-term cultures, while maintaining their angiogenic capacity. Moreover, Akt-transduced embryonic ECs form functional perfused vessels in vivo that anastomose with host blood vessels. We provide evidence for a novel function of Akt in stabilizing EC identity, whereby the activated form of the protein protects mouse ES cell-derived ECs from TGFβ-mediated transdifferentiation by downregulating SMAD3. These findings identify a role for Akt in regulating the developmental potential of ES cell-derived ECs and demonstrate that active Akt maintains endothelial identity in embryonic ECs by interfering with active TGFβ-mediated processes that would ordinarily usher these cells to alternate fates. © AlphaMed Press.

  19. Time course of the dependence of associative memory retrieval on the entorhinal cortex.

    PubMed

    Chen, Xi; Liao, Zhengli; Wong, Yin Ting; Guo, Yiping; He, Jufang

    2014-12-01

    As the gateway between the hippocampal system and the neocortex, the entorhinal cortex (EC) is hypothesized to be the hub in which the transformation of recent memory to remote memory is processed. We explored the role of the EC on the retrieval of recent and remote associative fear memory. A within-subject approach was adopted to compare the freezing rates of rats in EC intact and EC inactivated conditions following trace fear conditioning. The EC was inactivated by infusing an AMPA antagonist. The fear conditioning used a combined visual and auditory conditioned stimulus with a foot shock. On week 1 following the conditioning, the rats in the EC intact condition exhibited a freezing rate of 92.4±9.5% in response to the light stimulus compared with a 6.3±7.9% freezing rate in the EC inactivated condition. The freezing rates were 87.0±17.8% and 4.7±6.5% on week 2 in the EC intact and inactivated conditions, respectively. These results indicate that the EC participates in the retrieval of associative memory. Extinction of the fear memory was observed in the EC intact condition, as the mean freezing rate decreased to 62.7±23.0% on week 4 and 41.2±26.4% on week 5. However, the freezing rate increased to 26.8±14.2% on week 4 and 22.3±14.4% on week 5 in the EC inactivated condition. The normalized dependence of fear memory retrieval on the EC was 93.2±8.3% on week 1, and significantly decreased on weeks 4 and 5. In summary, the retrieval of associative memory depends on the EC, but this dependence decreases over time. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Olive mill wastewater treatment in Jordan: A Review

    NASA Astrophysics Data System (ADS)

    Bawab, Abeer Al; Ghannam, Noor; Abu-Mallouh, Saida; Bozeya, Ayat; Abu-Zurayk, Rund A.; Al-Ajlouni, Yazan A.; Alshawawreh, Fida'a.; Odeh, Fadwa; Abu-Dalo, Muna A.

    2018-02-01

    The environmental impact of olive mill wastewater (OMW) pollution is a public concern. OMW contains high levels of phenols, organic compounds, chemical oxygen demand (COD), biological oxygen demand (BOD), microorganisms, nutrients, and toxic compounds. The treatment of OMW has been investigated by many researchers in the Mediterranean region, using several treatment techniques to remove contaminants from OMW. These techniques include chemical, biological, physiochemical, and biophysical techniques. Surfactants and some adsorbents were used in chemical techniques, anaerobic and aerobic in biological techniques, while the combined treatment methods used Electroosmosis, ozonation and electrocoagulation processes as physiochemical methods, and ultrasonic irradiation combined with aerobic biodegradation as biophysical method. The effects of OMW, whether treated or untreated, have been evaluated on both plants’ growth and soil properties. The treatment methods as well as the environmental impact of OMW in Jordan were summarized in this review.

  1. Sequential Combination of Electro-Fenton and Electrochemical Chlorination Processes for the Treatment of Anaerobically-Digested Food Wastewater.

    PubMed

    Shin, Yong-Uk; Yoo, Ha-Young; Kim, Seonghun; Chung, Kyung-Mi; Park, Yong-Gyun; Hwang, Kwang-Hyun; Hong, Seok Won; Park, Hyunwoong; Cho, Kangwoo; Lee, Jaesang

    2017-09-19

    A two-stage sequential electro-Fenton (E-Fenton) oxidation followed by electrochemical chlorination (EC) was demonstrated to concomitantly treat high concentrations of organic carbon and ammonium nitrogen (NH 4 + -N) in real anaerobically digested food wastewater (ADFW). The anodic Fenton process caused the rapid mineralization of phenol as a model substrate through the production of hydroxyl radical as the main oxidant. The electrochemical oxidation of NH 4 + by a dimensionally stable anode (DSA) resulted in temporal concentration profiles of combined and free chlorine species that were analogous to those during the conventional breakpoint chlorination of NH 4 + . Together with the minimal production of nitrate, this confirmed that the conversion of NH 4 + to nitrogen gas was electrochemically achievable. The monitoring of treatment performance with varying key parameters (e.g., current density, H 2 O 2 feeding rate, pH, NaCl loading, and DSA type) led to the optimization of two component systems. The comparative evaluation of two sequentially combined systems (i.e., the E-Fenton-EC system versus the EC-E-Fenton system) using the mixture of phenol and NH 4 + under the predetermined optimal conditions suggested the superiority of the E-Fenton-EC system in terms of treatment efficiency and energy consumption. Finally, the sequential E-Fenton-EC process effectively mineralized organic carbon and decomposed NH 4 + -N in the real ADFW without external supply of NaCl.

  2. Evaluative conditioning may incur attentional costs.

    PubMed

    Pleyers, Gordy; Corneille, Olivier; Yzerbyt, Vincent; Luminet, Olivier

    2009-04-01

    Evaluative conditioning (EC) refers to changes in the liking of an affectively neutral stimulus (conditioned stimulus, or CS) after pairing this stimulus with an affect-laden stimulus (unconditioned stimulus, or US). Several authors proposed that EC incurs little or no attentional cost. Using a rigorous design, we provide evidence that a reduction in attentional resources may have a negative impact on EC. Additional analyses also revealed that participants correctly encoded fewer CS-US pairings when their attentional resources were depleted. Replicating Pleyers, Corneille, Luminet, and Yzerbyt's (2007) findings, EC was also obtained only for CSs that could be correctly linked to their associated US in the context of an identification task. This research clarifies the role of higher order processes in EC and has significant practical implications. Copyright (c) 2009 APA, all rights reserved.

  3. Ecophysiological variation of transpiration of pine forests: synthesis of new and published results

    Treesearch

    Pantana Tor-ngern; Ram Oren; Andrew C. Oishi; Joshua M. Uebelherr; Sari Palmroth; Lasse Tarvainen; Mikaell Ottosson-Löfvenius; Sune Linder; Jean-Christophe Domec; Torgny Näsholm

    2017-01-01

    Canopy transpiration (EC) is a large fraction of evapotranspiration, integrating physical and biological processes within the energy, water, and carbon cycles of forests. Quantifying EC is of both scientific and practical importance, providing information relevant to...

  4. Lipid Droplet Biogenesis and Function in the Endothelium.

    PubMed

    Kuo, Andrew; Lee, Monica Y; Sessa, William C

    2017-04-14

    Fatty acids (FA) are transported across the capillary endothelium to parenchymal tissues. However, it is not known how endothelial cells (EC) from large vessels process a postprandial surge of FA. This study was designed to characterize lipid droplet (LD) formation in EC by manipulating pathways leading to the formation and degradation of LD. In addition, several functions of LD-derived FA were assessed. LD were present in EC lining the aorta after the peak in plasma triglycerides initiated by a gavage of olive oil in mice, in vivo. Similarly, in isolated aorta, oleic acid treatment generates LD in EC ex vivo. Cultured EC readily form LD largely via the enzyme DGAT (diacylglycerol O-acyltransferase 1) and degrade LD via ATGL (adipocyte triglyceride lipase) after FA loading. Functionally, LD-derived FA are dynamically regulated and function to protect EC from lipotoxic stress and provide FA for metabolic needs. Our results delineate endothelial LD dynamics for the first time in vivo and in vitro. Moreover, LD formation protects EC from lipotoxic stress, regulates EC glycolysis, and provides a source of FA for adjacent cells in the vessel wall or tissues. © 2017 American Heart Association, Inc.

  5. Amygdala activity and prefrontal cortex-amygdala effective connectivity to emerging emotional faces distinguish remitted and depressed mood states in bipolar disorder.

    PubMed

    Perlman, Susan B; Almeida, Jorge R C; Kronhaus, Dina M; Versace, Amelia; Labarbara, Edmund J; Klein, Crystal R; Phillips, Mary L

    2012-03-01

    Few studies have employed effective connectivity (EC) to examine the functional integrity of neural circuitry supporting abnormal emotion processing in bipolar disorder (BD), a key feature of the illness. We used Granger Causality Mapping (GCM) to map EC between the prefrontal cortex (PFC) and bilateral amygdala and a novel paradigm to assess emotion processing in adults with BD. Thirty-one remitted adults with BD [(remitted BD), mean age = 32 years], 21 adults with BD in a depressed episode [(depressed BD), mean age = 33 years], and 25 healthy control participants [(HC), mean age = 31 years] performed a block-design emotion processing task requiring color-labeling of a color flash superimposed on a task-irrelevant face morphing from neutral to emotional (happy, sad, angry, or fearful). GCM measured EC preceding (top-down) and following (bottom-up) activity between the PFC and the left and right amygdalae. Our findings indicated patterns of abnormally elevated bilateral amygdala activity in response to emerging fearful, sad, and angry facial expressions in remitted-BD subjects versus HC, and abnormally elevated right amygdala activity to emerging fearful faces in depressed-BD subjects versus HC. We also showed distinguishable patterns of abnormal EC between the amygdala and dorsomedial and ventrolateral PFC, especially to emerging happy and sad facial expressions in remitted-BD and depressed-BD subjects. EC measures of neural system level functioning can further understanding of neural mechanisms associated with abnormal emotion processing and regulation in BD. Our findings suggest major differences in recruitment of amygdala-PFC circuitry, supporting implicit emotion processing between remitted-BD and depressed-BD subjects, which may underlie changes from remission to depression in BD. © 2012 John Wiley and Sons A/S.

  6. OM/OC Ratio and Specific Attenuation Coefficient in Ambient Particulate Matter at a Rural Site in Southern Ontario: Implications for Aerosol Aging and Emission Sources

    NASA Astrophysics Data System (ADS)

    Chan, T. W.; Huang, L.; Leaitch, R.; Sharma, S.; Brook, J.; Slowik, J.; Abbatt, J.

    2008-05-01

    Carbonaceous species (organic carbon (OC) and elemental carbon (EC)) contribute a large portion of atmospheric fine particle mass and influence air quality, human health, and climate forcing. However, their emission sources and atmospheric aging processes are not well understood. The OM/OC ratio, defined as the organic mass per unit OC mass, is useful to understand the degree of oxidation of aerosol particles in atmospheric processes. We define the modified BC/EC (mod BC/EC) ratio as the ratio of the non-scattering corrected absorption coefficient per unit mass of EC. The mod BC/EC ratio has a similar meaning as the site specific attenuation coefficient, which is an important parameter used to convert light absorption measurements to black carbon mass. The mod BC/EC ratio can vary due to light scattering effect on absorption measurements, in which the oxygenated organics may play a role. The pyrolysis organic carbon (POC) is defined as the carbon mass fraction obtained at T= 870°C under a pure helium environment using the thermal separation method [Huang et al., 2006]. Since POC mass is generally proportional to the amount of oxygenated OC, studying the relationships among OC, EC, POC, as well as OM/OC and mod BC/EC ratios may help us understand the mechanisms of aerosol aging from different emission sources. Two 1-month field studies were conducted at a rural site in southern Ontario (NW of Toronto) during fall 2005 and spring 2007. Quartz filter samples were collected and analyzed for OC, POC, and EC concentrations using a thermal/optical method [Huang et al., 2006]. Together with the total organic matter measured by an Aerodyne Aerosol Mass Spectrometer (AMS) and the absorption coefficient obtained from a Particle Soot Absorption Photometer (PSAP), the OM/OC and mod BC/EC ratios for ambient aerosols were obtained. Our results show that when air mass was mainly from south, OC, POC, and EC were relatively high, with average ratios of OC/EC, OM/OC, and POC/EC as 1.94, 1.41, and 0.52, respectively; this indicates significant anthropogenic impacts and relatively large portion of oxygenated OC, which might be due to either primary emissions or photo-chemical reactions occurred in a short period of time. When air mass was mainly from north, OC, POC, and EC were much lower, with average ratios of OC/EC, OM/OC, and POC/EC as 3.10, 1.20, and 0.79, respectively; this suggests less influence from anthropogenic emissions and relatively aged air mass from biogenic-source dominated clean air. Using POC, we estimate the specific attenuation at the site to be 5.8 m2 g-1 independent of the air mass origin. The relationships among OM/OC, mod BC/EC, and POC will be further discussed. References: Huang, L., Brook, J.R., Zhang, W., Li, S.M., Graham, L., Ernst, D., Chivulescu, A., and Lu, G. (2006) Stable isotope measurements of carbon fractions (OC/EC) in airborne particulate: a new dimension for source characterization and apportionment, Atmospheric Environment, 40, 2690-2705.

  7. A combined CaO/electrochemical treatment of the acid mine drainage from the "Robule" Lake.

    PubMed

    Orescanin, Visnja; Kollar, Robert

    2012-01-01

    The purpose of this work was development and application of the purification system suitable for the treatment of the acid mine drainage (AMD) accumulated in the "Robule" Lake, which represents the part of the Bor copper mining and smelting complex, Serbia. The study was undertaken in order to minimize adverse effect on the environment caused by the discharge of untreated AMD, which was characterized with low pH value (2.63) and high concentration of heavy metals (up to 610 mg/L) and sulfates (up to 12,000 mg/L). The treatment of the effluent included pretreatment/pH adjustment with CaO followed by electrocoagulation using iron and aluminum electrode sets. Following the final treatment, the decrease in the concentration of heavy metals ranged from 40 up to 61000 times depending on the metal and its initial concentration. The parameters, color and turbidity were removed completely in the pretreatment step, while the removal efficiencies for other considered parameters were as follows: EC = 55.48%, SO(4) (2-) = 70.83%, Hg = 98.36%, Pb = 97.50%, V = 98.43%, Cr = 99.86%, Mn = 97.96%, Fe = 100.00%, Co = 99.96%, Ni = 99.78%, Cu = 99.99% and Zn = 99.94%. Because the concentrations of heavy metals in the electrochemically treated AMD (ranging from 0.001 to 0.336 mg/L) are very low, the negative impact of this effluent on the aquatic life and humans is not expected. The sludge generated during the treatment of AMD is suitable for reuse for at least two purposes (pretreatment of AMD and covering of the flotation waste heap). From the presented results, it could be concluded that electrochemical treatment is a suitable approach for the treatment of AMD.

  8. The Cannabinoid System and Pain

    PubMed Central

    Woodhams, Stephen G.; Chapman, Victoria; Finn, David P.; Hohmann, Andrea G.; Neugebauer, Volker

    2018-01-01

    Chronic pain states are highly prevalent and yet poorly controlled by currently available analgesics, representing an enormous clinical, societal, and economic burden. Existing pain medications have significant limitations and adverse effects including tolerance, dependence, gastrointestinal dysfunction, cognitive impairment, and a narrow therapeutic window, making the search for novel analgesics ever more important. In this article, we review the role of an important endogenous pain control system, the endocannabinoid (EC) system, in the sensory, emotional, and cognitive aspects of pain. Herein, we briefly cover the discovery of the EC system and its role in pain processing pathways, before concentrating on three areas of current major interest in EC pain research; 1. Pharmacological enhancement of endocannabinoid activity (via blockade of EC metabolism or allosteric modulation of CB1 receptors); 2. The EC System and stress-induced modulation of pain; and 3. The EC system & medial prefrontal cortex (mPFC) dysfunction in pain states. Whilst we focus predominantly on the preclinical data, we also include extensive discussion of recent clinical failures of endocannabinoid-related therapies, the future potential of these approaches, and important directions for future research on the EC system and pain. PMID:28625720

  9. Evaluation of enhanced coagulation pretreatment to improve ozone oxidation efficiency in wastewater.

    PubMed

    Wert, Eric C; Gonzales, Sarah; Dong, Mei Mei; Rosario-Ortiz, Fernando L

    2011-10-15

    Enhanced coagulation (EC) using ferric chloride was evaluated as a pretreatment process to improve the efficiency of ozone (O3) for the oxidation of trace organic contaminants in wastewater. At the applied dosages (10-30 mg/L as Fe), EC pretreatment removed between 10 and 47% of the dissolved organic carbon (DOC) from the three wastewaters studied. Size exclusion chromatography (SEC) showed that EC preferentially removed higher apparent molecular weight (AMW) compounds. Subsequent O3 testing was performed using an O3:DOC ratio of 1. Results showed that O3 exposures were similar even though the required doses were reduced by 10-47% by the EC pretreatment process. Hydroxyl radical (HO·) exposure, measured by parachlorobenzoic acid (pCBA), showed 10% reduction when using a FeCl3 dose of 30 mg/L, likely due to the lower O3 dose and decreased production of HO· during the initial phase of O3 decomposition (t<30 s). The oxidation of 13 trace organic contaminants (including atenolol, carbamazepine, DEET, diclofenac, dilantin, gemfibrozil, ibuprofen, meprobamate, naproxen, primidone, sulfamethoxazole, triclosan, and trimethoprim) was evaluated after EC and O3 treatment. EC was ineffective at removing any of the contaminants, while O3 oxidation reduced the concentration of compounds according to their reaction rate constants with O3 and HO·. Copyright © 2011. Published by Elsevier Ltd.

  10. Analysis of ECs and related compounds in plasma: artifactual isomerization and ex vivo enzymatic generation of 2-MGs.

    PubMed

    Pastor, Antoni; Farré, Magí; Fitó, Montserrat; Fernandez-Aranda, Fernando; de la Torre, Rafael

    2014-05-01

    The analysis of peripheral endocannabinoids (ECs) is a good biomarker of the EC system. Their concentrations, from clinical studies, strongly depend on sample collection and time processing conditions taking place in clinical and laboratory settings. The analysis of 2-monoacylglycerols (MGs) (i.e., 2-arachidonoylglycerol or 2-oleoylglycerol) is a particularly challenging issue because of their ex vivo formation and chemical isomerization that occur after blood sample collection. We provide evidence that their ex vivo formation can be minimized by adding Orlistat, an enzymatic lipase inhibitor, to plasma. Taking into consideration the low cost of Orlistat, we recommend its addition to plasma collecting tubes while maintaining sample cold chain until storage. We have validated a method for the determination of the EC profile of a range of MGs and N-acylethanolamides in plasma that preserves the original isomer ratio of MGs. Nevertheless, the chemical isomerization of 2-MGs can only be avoided by an immediate processing and analysis of samples due to their instability during conservation. We believe that this new methodology can aid in the harmonization of the measurement of ECs and related compounds in clinical samples.

  11. Nanoclay/Polymer Composite Powders for Use in Laser Sintering Applications: Effects of Nanoclay Plasma Treatment

    NASA Astrophysics Data System (ADS)

    Almansoori, Alaa; Majewski, Candice; Rodenburg, Cornelia

    2017-11-01

    Plasma-etched nanoclay-reinforced Polyamide 12 (PA12) powder is prepared with its intended use in selective laser sintering (LS) applications. To replicate the LS process we present a downward heat sintering (DHS) process, carried out in a hot press, to fabricate tensile test specimens from the composite powders. The DHS parameters are optimized through hot stage microscopy, which reveal that the etched clay (EC)-based PA12 (EC/PA12) nanocomposite powder melts at a temperature 2°C higher than that of neat PA12, and 1-3°C lower than that of the nonetched clay-based nanocompsite (NEC/PA12 composite). We show that these temperature differences are critical to successful LS. The distribution of EC and NEC onto PA12 is investigated by scanning electron microscopy (SEM). SEM images show clearly that the plasma treatment prevents the micron-scale aggregation of the nanoclay, resulting in an improved elastic modulus of EC/PA12 when compared with neat PA12 and NEC/PA12. Moreover, the reduction in elongation at break for EC/PA12 is less pronounced than for NEC/PA12.

  12. Prospective Study of Burn Wound Excision of the Hands

    DTIC Science & Technology

    1983-06-01

    Houston, Texas. sion (10, 11). This method allows the sequential removal Presented at the Forty-second Annual Session of The American of nonviable tissue...ultrasonography. Es- days, after which all dressings were removed and a more charotomies of upper extremities were carried out if vigorous physical therapy...sponges, followed by mild compression wrapping and interphalangeal joints. The thumb was abducted and elevation. Electrocoagulation of bleeding points

  13. Evaluating Emergent Constraints for Equilibrium Climate Sensitivity

    DOE PAGES

    Caldwell, Peter M.; Zelinka, Mark D.; Klein, Stephen A.

    2018-04-23

    Emergent constraints are quantities that are observable from current measurements and have skill predicting future climate. Here, this study explores 19 previously proposed emergent constraints related to equilibrium climate sensitivity (ECS; the global-average equilibrium surface temperature response to CO 2 doubling). Several constraints are shown to be closely related, emphasizing the importance for careful understanding of proposed constraints. A new method is presented for decomposing correlation between an emergent constraint and ECS into terms related to physical processes and geographical regions. Using this decomposition, one can determine whether the processes and regions explaining correlation with ECS correspond to the physicalmore » explanation offered for the constraint. Shortwave cloud feedback is generally found to be the dominant contributor to correlations with ECS because it is the largest source of intermodel spread in ECS. In all cases, correlation results from interaction between a variety of terms, reflecting the complex nature of ECS and the fact that feedback terms and forcing are themselves correlated with each other. For 4 of the 19 constraints, the originally proposed explanation for correlation is borne out by our analysis. These four constraints all predict relatively high climate sensitivity. The credibility of six other constraints is called into question owing to correlation with ECS coming mainly from unexpected sources and/or lack of robustness to changes in ensembles. Another six constraints lack a testable explanation and hence cannot be confirmed. Lastly, the fact that this study casts doubt upon more constraints than it confirms highlights the need for caution when identifying emergent constraints from small ensembles.« less

  14. An active learning approach for rapid characterization of endothelial cells in human tumors.

    PubMed

    Padmanabhan, Raghav K; Somasundar, Vinay H; Griffith, Sandra D; Zhu, Jianliang; Samoyedny, Drew; Tan, Kay See; Hu, Jiahao; Liao, Xuejun; Carin, Lawrence; Yoon, Sam S; Flaherty, Keith T; Dipaola, Robert S; Heitjan, Daniel F; Lal, Priti; Feldman, Michael D; Roysam, Badrinath; Lee, William M F

    2014-01-01

    Currently, no available pathological or molecular measures of tumor angiogenesis predict response to antiangiogenic therapies used in clinical practice. Recognizing that tumor endothelial cells (EC) and EC activation and survival signaling are the direct targets of these therapies, we sought to develop an automated platform for quantifying activity of critical signaling pathways and other biological events in EC of patient tumors by histopathology. Computer image analysis of EC in highly heterogeneous human tumors by a statistical classifier trained using examples selected by human experts performed poorly due to subjectivity and selection bias. We hypothesized that the analysis can be optimized by a more active process to aid experts in identifying informative training examples. To test this hypothesis, we incorporated a novel active learning (AL) algorithm into FARSIGHT image analysis software that aids the expert by seeking out informative examples for the operator to label. The resulting FARSIGHT-AL system identified EC with specificity and sensitivity consistently greater than 0.9 and outperformed traditional supervised classification algorithms. The system modeled individual operator preferences and generated reproducible results. Using the results of EC classification, we also quantified proliferation (Ki67) and activity in important signal transduction pathways (MAP kinase, STAT3) in immunostained human clear cell renal cell carcinoma and other tumors. FARSIGHT-AL enables characterization of EC in conventionally preserved human tumors in a more automated process suitable for testing and validating in clinical trials. The results of our study support a unique opportunity for quantifying angiogenesis in a manner that can now be tested for its ability to identify novel predictive and response biomarkers.

  15. Evaluating Emergent Constraints for Equilibrium Climate Sensitivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caldwell, Peter M.; Zelinka, Mark D.; Klein, Stephen A.

    Emergent constraints are quantities that are observable from current measurements and have skill predicting future climate. Here, this study explores 19 previously proposed emergent constraints related to equilibrium climate sensitivity (ECS; the global-average equilibrium surface temperature response to CO 2 doubling). Several constraints are shown to be closely related, emphasizing the importance for careful understanding of proposed constraints. A new method is presented for decomposing correlation between an emergent constraint and ECS into terms related to physical processes and geographical regions. Using this decomposition, one can determine whether the processes and regions explaining correlation with ECS correspond to the physicalmore » explanation offered for the constraint. Shortwave cloud feedback is generally found to be the dominant contributor to correlations with ECS because it is the largest source of intermodel spread in ECS. In all cases, correlation results from interaction between a variety of terms, reflecting the complex nature of ECS and the fact that feedback terms and forcing are themselves correlated with each other. For 4 of the 19 constraints, the originally proposed explanation for correlation is borne out by our analysis. These four constraints all predict relatively high climate sensitivity. The credibility of six other constraints is called into question owing to correlation with ECS coming mainly from unexpected sources and/or lack of robustness to changes in ensembles. Another six constraints lack a testable explanation and hence cannot be confirmed. Lastly, the fact that this study casts doubt upon more constraints than it confirms highlights the need for caution when identifying emergent constraints from small ensembles.« less

  16. Comparison of the efficacy of two combined therapies for peptic ulcer bleeding: adrenaline injection plus haemoclipping versus adrenaline injection followed by bipolar electrocoagulation

    PubMed Central

    Świdnicka-Siergiejko, Agnieszka; Wróblewski, Eugeniusz; Baniukiewicz, Andrzej; Dąbrowski, Andrzej

    2014-01-01

    Introduction Peptic ulcer remains the most frequent cause of upper gastrointestinal bleeding. Treatment of bleeding with simultaneous combination of two endoscopic techniques has proved to be more efficient than monotherapy. None of the published comparative studies of various contact coagulation modalities have confirmed the superiority of one of these techniques over the others. Aim To compare the therapeutic outcomes of the use of a device enabling both injection of adrenaline solution and bipolar electrocoagulation (A + BE) to those of combined adrenaline injection with mechanical therapy (haemostatic clips) (A + HC) in the treatment of peptic ulcer bleeding. Material and methods Fifty-two subjects with bleeding ulcers were assigned to the A + BE group, and 55 patients were treated with A + HC. Results Overall, treatment failed in 20 patients (20/107, 18.7%): in 10 individuals from the A + BE group (10/52; 18.2%) and in 10 individuals from the A + HC group (10/55; 19.2%) (p > 0.05). Primary haemostasis was not obtained in 7 patients (6.5%): in 4 patients in the A + BE group and in 3 patients in the A + HC group (p > 0.05). Ten individuals (9.3%) experienced recurrent bleeding during hospitalisation: 4 patients from the A + BE group and 6 patients from the A + HC group (p > 0.05). Finally, in 96.3% of the patients (n = 103) the endoscopic treatment proved efficient with regards to obtaining haemostasis during hospitalisation. Surgical intervention was required in 4 individuals (3.7%): 2 patients in the A + BE group and 2 patients treated with A + HC (p > 0.05). Three patients (2.8%) – all from the A + HC group – died during hospitalisation. No significant intergroup differences were documented with regards to the mean number of transfused blood units and the mean length of hospital stay. Conclusions The efficacy of combined endoscopic treatment of ulcer bleeding with a probe enabling simultaneous bipolar electrocoagulation and adrenaline injection seems comparable to the widely used dual technique of adrenaline injection and haemostatic clipping. PMID:25653731

  17. Design of polyelectrolyte multilayer membranes for ion rejection and wastewater effluent treatment

    NASA Astrophysics Data System (ADS)

    Sanyal, Oishi

    Polyelectrolyte multilayer (PEM) membranes present a special class of nanostructured membranes which have potential applications in a variety of water treatment operations. These membranes are fabricated by the layer-by-layer (LbL) assembly of alternately charged polyelectrolytes on commercial membrane surfaces. A large variety of polyelectrolytes and their varied deposition conditions (pH, number of bilayers etc.) allow very fine tuning of the membrane performance in terms of permeability and rejection. The first part of this thesis is about the application of PEM membranes to the removal of perchlorate ion from water. Being a monovalent ion, it is most effectively removed by a reverse osmosis (RO) membrane. However, these membranes inherently have very low fluxes which lead to high pressure requirements. In our work, we modified the surface of a nanofiltration (NF) membrane by the LbL assembly of oppositely charged polyelectrolytes. The appropriate tuning of the LbL conditions led to the development of a membrane with significantly higher flux than RO membranes but with equivalent perchlorate rejection. This was one of the best trade-offs offered by PEM membranes for monovalent ion rejection as has been reported in literature so far. While PEM membranes have mostly shown great potential in ion-rejection studies, they have seldom been tested for real wastewater effluents. The second part of this thesis, therefore, deals with evaluating the applicability of PEM membranes to treating an electrocoagulation (EC)-treated high strength wastewater. Two types of very commonly used polyelectrolyte combinations were tried out -- one of which was an ionically crosslinked system and the other one was covalently crosslinked. Both the types of PEM membranes showed a high level of COD reduction from the feed stream with higher fluxes than commercial RO membranes. One major challenge in using membranes for wastewater treatment is their fouling propensity. Like many other wastewater samples, the EC treated solution also contained a fair amount of organic foulants. These PEM membranes, however, indicated better anti-fouling properties than commercial NF/RO membranes under normal flow conditions. The last part of our work was focused on improving the anti-fouling properties of these membranes by the incorporation of clay nanoplatelets within polyelectrolyte multilayers. In this project, a commercial polyethersulfone (PES) membrane was modified by clay-polyelectrolyte composite thin films and tested against the EC effluent under tangential flow conditions. In comparison to the PEM membranes, these clay-PEM (c-PEM) hybrid membranes offered superior anti-fouling properties with higher fluxes and also required lesser number of layers. On crosslinking the polyelectrolytes, the c-PEM membranes yielded improved anti-fouling properties and high COD removal. Introduction of these inorganic nanoplatelets, however, led to a significant decline in the initial flux of the modified membranes as compared to bare PES membranes, which therefore necessitates further optimization. Some strategies which can potentially help in optimizing the performance of these c-PEM membranes have been discussed in this thesis.

  18. Global land-atmosphere coupling associated with cold climate processes

    NASA Astrophysics Data System (ADS)

    Dutra, Emanuel

    This dissertation constitutes an assessment of the role of cold processes, associated with snow cover, in controlling the land-atmosphere coupling. The work was based on model simulations, including offline simulations with the land surface model HTESSEL, and coupled atmosphere simulations with the EC-EARTH climate model. A revised snow scheme was developed and tested in HTESSEL and EC-EARTH. The snow scheme is currently operational at the European Centre for Medium-Range Weather Forecasts integrated forecast system, and in the default configuration of EC-EARTH. The improved representation of the snowpack dynamics in HTESSEL resulted in improvements in the near surface temperature simulations of EC-EARTH. The new snow scheme development was complemented with the option of multi-layer version that showed its potential in modeling thick snowpacks. A key process was the snow thermal insulation that led to significant improvements of the surface water and energy balance components. Similar findings were observed when coupling the snow scheme to lake ice, where lake ice duration was significantly improved. An assessment on the snow cover sensitivity to horizontal resolution, parameterizations and atmospheric forcing within HTESSEL highlighted the role of the atmospheric forcing accuracy and snowpack parameterizations in detriment of horizontal resolution over flat regions. A set of experiments with and without free snow evolution was carried out with EC-EARTH to assess the impact of the interannual variability of snow cover on near surface and soil temperatures. It was found that snow cover interannual variability explained up to 60% of the total interannual variability of near surface temperature over snow covered regions. Although these findings are model dependent, the results showed consistency with previously published work. Furthermore, the detailed validation of the snow dynamics simulations in HTESSEL and EC-EARTH guarantees consistency of the results.

  19. RhoC and ROCKs regulate cancer cell interactions with endothelial cells.

    PubMed

    Reymond, Nicolas; Im, Jae Hong; Garg, Ritu; Cox, Susan; Soyer, Magali; Riou, Philippe; Colomba, Audrey; Muschel, Ruth J; Ridley, Anne J

    2015-06-01

    RhoC is a member of the Rho GTPase family that is implicated in cancer progression by stimulating cancer cell invasiveness. Here we report that RhoC regulates the interaction of cancer cells with vascular endothelial cells (ECs), a crucial step in the metastatic process. RhoC depletion by RNAi reduces PC3 prostate cancer cell adhesion to ECs, intercalation between ECs as well as transendothelial migration in vitro. Depletion of the kinases ROCK1 and ROCK2, two known RhoC downstream effectors, similarly decreases cancer interaction with ECs. RhoC also regulates the extension of protrusions made by cancer cells on vascular ECs in vivo. Transient RhoC depletion is sufficient to reduce both early PC3 cell retention in the lungs and experimental metastasis formation in vivo. Our results indicate RhoC plays a central role in cancer cell interaction with vascular ECs, which is a critical event for cancer progression. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Fatty acid carbon is essential for dNTP synthesis in endothelial cells

    PubMed Central

    Missiaen, Rindert; Queiroz, Karla CS; Borgers, Gitte; Elia, Ilaria; Zecchin, Annalisa; Cantelmo, Anna Rita; Christen, Stefan; Goveia, Jermaine; Heggermont, Ward; Goddé, Lucica; Vinckier, Stefan; Van Veldhoven, Paul P.; Eelen, Guy; Schoonjans, Luc; Gerhardt, Holger; Dewerchin, Mieke; Baes, Myriam; De Bock, Katrien; Ghesquière, Bart; Lunt, Sophia Y.; Fendt, Sarah-Maria; Carmeliet, Peter

    2015-01-01

    The metabolism of endothelial cells (ECs) during vessel sprouting remains poorly studied. Here, we report that endothelial loss of CPT1a, a rate-limiting enzyme of fatty acid oxidation (FAO), caused vascular sprouting defects due to impaired proliferation, not migration of ECs. Reduction of FAO in ECs did not cause energy depletion or disturb redox homeostasis, but impaired de novo nucleotide synthesis for DNA replication. Isotope labeling studies in control ECs showed that fatty acid carbons substantially replenished the Krebs cycle, and were incorporated into aspartate (a nucleotide precursor), uridine monophosphate (a precursor of pyrimidine nucleoside triphosphates) and DNA. CPT1a silencing reduced these processes and depleted EC stores of aspartate and deoxyribonucleoside triphosphates. Acetate (metabolized to acetyl-CoA, thereby substituting for the depleted FAO-derived acetyl-CoA) or a nucleoside mix rescued the phenotype of CPT1a-silenced ECs. Finally, CPT1 blockade inhibited pathological ocular angiogenesis, suggesting a novel strategy for blocking angiogenesis. PMID:25830893

  1. Autonomy and Non-autonomy of Angiogenic Cell Movements Revealed by Experiment-Driven Mathematical Modeling.

    PubMed

    Sugihara, Kei; Nishiyama, Koichi; Fukuhara, Shigetomo; Uemura, Akiyoshi; Arima, Satoshi; Kobayashi, Ryo; Köhn-Luque, Alvaro; Mochizuki, Naoki; Suda, Toshio; Ogawa, Hisao; Kurihara, Hiroki

    2015-12-01

    Angiogenesis is a multicellular phenomenon driven by morphogenetic cell movements. We recently reported morphogenetic vascular endothelial cell (EC) behaviors to be dynamic and complex. However, the principal mechanisms orchestrating individual EC movements in angiogenic morphogenesis remain largely unknown. Here we present an experiment-driven mathematical model that enables us to systematically dissect cellular mechanisms in branch elongation. We found that cell-autonomous and coordinated actions governed these multicellular behaviors, and a cell-autonomous process sufficiently illustrated essential features of the morphogenetic EC dynamics at both the single-cell and cell-population levels. Through refining our model and experimental verification, we further identified a coordinated mode of tip EC behaviors regulated via a spatial relationship between tip and follower ECs, which facilitates the forward motility of tip ECs. These findings provide insights that enhance our mechanistic understanding of not only angiogenic morphogenesis, but also other types of multicellular phenomenon. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Don't Worry, Be Happy: Endocannabinoids and Cannabis at the Intersection of Stress and Reward.

    PubMed

    Volkow, Nora D; Hampson, Aidan J; Baler, Ruben D

    2017-01-06

    Cannabis enables and enhances the subjective sense of well-being by stimulating the endocannabinoid system (ECS), which plays a key role in modulating the response to stress, reward, and their interactions. However, over time, repeated activation of the ECS by cannabis can trigger neuroadaptations that may impair the sensitivity to stress and reward. This effect, in vulnerable individuals, can lead to addiction and other adverse consequences. The recent shift toward legalization of medical or recreational cannabis has renewed interest in investigating the physiological role of the ECS as well as the potential health effects, both adverse and beneficial, of cannabis. Here we review our current understanding of the ECS and its complex physiological roles. We discuss the implications of this understanding vis-á-vis the ECS's modulation of stress and reward and its relevance to mental disorders in which these processes are disrupted (i.e., addiction, depression, posttraumatic stress disorder, schizophrenia), along with the therapeutic potential of strategies to manipulate the ECS for these conditions.

  3. Sample support and resistivity imaging interpretation

    NASA Astrophysics Data System (ADS)

    Bentley, L. R.; Gharibi, M.

    2003-04-01

    Three-D Electrical Resistivity Imaging (ERI) is a powerful technique that can be used to improve site characterization. In order to integrate ERI with other site characterization measurements such as soil and water chemistry, it is necessary to understand the sample support of various data. We have studied a decommissioned sour gas processing plant which has experienced releases of glycol and amine. Ammonium and acetic acid are degradation products that cause elevated electrical conductivity (EC) in groundwater and soils.The site is underlain by glacial till that is fractured and has thin sand lenses. 3-D ERI inversion results, direct push tool EC and core EC from the same location are well correlated. However, groundwater EC from piezometer installations are poorly correlated with ERI EC. We hypothesize that the ERI, direct push and core EC are mainly meausuring relatively immobile pore water EC in the fine grain matrix. Piezometer water is derived from mobile groundwater that travels in preferred flow paths such as fractures and higher permeability sand lenses. Due to dewatering and other remediation efforts, the mobile groundwater can have a different chemistry, concentration and EC than the immobile pore water. Consequently, the sample support is different for the groundwater samples and the difference explains the poor correlation between ERI EC and groundwater sample EC. In this particular case, we have the potential to monitor the chemical evolution of the source areas, but cannot use ERI to monitor the chemical evolution of mobile groundwater.

  4. Assessing the quality of the ecological component of English Environmental Statements.

    PubMed

    Drayson, Katherine; Wood, Graham; Thompson, Stewart

    2015-09-01

    Environmental Impact Assessment (EIA) is a key tool to help ensure sustainable built development in more than 200 countries worldwide. Ecology is frequently a component of EIA and early reviews of Ecological Impact Assessment (EcIA) chapters identified scope for improvement at almost every stage of the EcIA process, regardless of country. However, there have been no reviews of UK EcIA chapters since 2000, despite important changes in biodiversity and planning legislation, policy and guidance. In addition, no UK EcIA chapter reviews have attempted to assign a grade or score to EcIA chapters (as has been done for reviews of US, Finnish and Indian EcIA chapters). Furthermore, no EcIA chapter reviews have attempted to use a scoring system to identify which variables determine EcIA chapter information content, beyond straightforward comparisons of EcIA chapters before and after the introduction of guidelines. A variant of the Biodiversity Assessment Index (BAI) was used to assign scores between zero and one to EcIA chapters based on a series of 47 questions drawn from EU legislation and professional guidance. 112 EcIA chapters for proposed developments that were subsequently granted planning permission in England were assessed. The mean BAI score was less than 0.5, indicating the presence of considerable information gaps in the majority of EcIA chapters. Of 13 predictor variables identified as having the potential to affect EcIA chapter quality, 10 were identified as significantly related to the BAI scores. A backward stepwise Generalized Linear Model identified the use of professional guidance, the ecological consultancy type and the length of the EcIA chapter as having the greatest combined explanatory power. As a result, several recommendations are made to help improve future EcIA chapter content, including formal EcIA chapter review, publicising the professional guidance to consultants, the provision of training and the introduction of an accreditation scheme for consultants involved in EcIA This approach could be replicated in other countries that conduct EIA. Context-dependent EcIA chapter review criteria (as in this paper) would help to identify targeted recommendations for improvement. Alternatively, a global set of review criteria could highlight areas of best practice that could then be exported to other countries. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  5. Degradation and ecotoxicity of dye Reactive Black 5 after reductive-oxidative process : Environmental Science and Pollution Research.

    PubMed

    Cuervo Lumbaque, Elisabeth; Gomes, Monike Felipe; Da Silva Carvalho, Vanessa; de Freitas, Adriane Martins; Tiburtius, Elaine Regina Lopes

    2017-03-01

    This research paper describes the study of a reduction-oxidation system using commercial steel wool (Fe 0 ) and H 2 O 2 for degradation of the dye Reactive Black 5 and aromatic compounds in water. The reductive process alone allowed the almost complete removal of color (97 ± 1 %) after 60 min of reaction. The decrease in spectral area (λ = 599 nm) associated with the chromophore group indicates breakage of the azo bonds. Moreover, the significant change in UV spectra can be associated with the formation of aromatic amines. Regarding the transformation products, a spectrophotometric method based on the diazotization reaction was employed to identify aromatic amines after reductive process, using sulfanilic acid as a model of aromatic amines. In addition, association with Fenton reagents improved the efficiency in the system with 93 ± 1 % degradation of intermediates formed during the reductive process. Ecotoxicological analysis revealed that the dye solution, after the reductive and oxidative processes, was not toxic to Lactuca sativa seeds. For Daphnia magna, the EC 50 (%) values observed revealed that dye solution has an EC 50 (%) = 74.1 and after reductive process, the toxicity increased (EC 50 (%) = 63.5), which might be related to the formation of aromatic amines. However, after the Fenton process, the EC 50 (%) was >100. These results demonstrated that the Fenton reaction using steel wool as an iron source was very efficient to decrease color, aromatic transformation products, and the ecotoxicity of Reactive Black 5 in solution.

  6. Photoinduced Single- and Multiple-Electron Dynamics Processes Enhanced by Quantum Confinement in Lead Halide Perovskite Quantum Dots

    DOE PAGES

    Vogel, Dayton J.; Kryjevski, Andrei; Inerbaev, Talgat; ...

    2017-03-21

    Methylammonium lead iodide perovskite (MAPbI 3) is a promising material for photovoltaic devices. A modification of MAPbI 3 into confined nanostructures is expected to further increase efficiency of solar energy conversion. Photoexcited dynamic processes in a MAPbI3 quantum dot (QD) have been modeled by many-body perturbation theory and nonadiabatic dynamics. A photoexcitation is followed by either exciton cooling (EC), its radiative (RR) or nonradiative recombination (NRR), or multiexciton generation (MEG) processes. Computed times of these processes fall in the order of MEG < EC < RR < NRR, where MEG is on the order of a few femtoseconds, EC ismore » in the picosecond range, while RR and NRR are on the order of nanoseconds. Computed time scales indicate which electronic transition pathways can contribute to increase in charge collection efficiency. Simulated mechanisms of relaxation and their rates show that quantum confinement promotes MEG in MAPbI 3 QDs.« less

  7. Adaptation of the Emotional Contagion Scale (ECS) and gender differences within the Greek cultural context.

    PubMed

    Kevrekidis, Pantelis; Skapinakis, Petros; Damigos, Dimitris; Mavreas, Venetsanos

    2008-08-21

    The Emotional Contagion Scale (ECS) is a self-report scale used to measure individual differences in susceptibility to converge towards the emotions expressed by others. The main aim of the present paper was to examine the psychometric properties of the Greek translation of the scale. The Greek ECS was completed by 691 undergraduate students (312 males and 379 females). To investigate the factor structure of the ECS, principal components analysis (PCA) was used. The results showed that a four-factor model was tenable. Regarding homogeneity, the Greek ECS version showed acceptable results for the full scale (alpha = 0.74) but not for all subscales. Gender differences were also identified concerning the susceptibility to emotional contagion between men and women. Women score significantly higher than men for all the different emotions described by the ECS (love, happiness, sadness) except the anger emotion, where there was no significant difference. The Greek version of the ECS showed good psychometric properties. It can be used to assess susceptibility to emotional contagion in correlation with psychopathological processes, mood and anxiety disorders primarily. The usefulness of the ECS in the fields of group psychotherapy and health psychology is also under consideration. Further investigation is needed in all these areas.

  8. Is evaluative conditioning really resistant to extinction? Evidence for changes in evaluative judgements without changes in evaluative representations.

    PubMed

    Gawronski, Bertram; Gast, Anne; De Houwer, Jan

    2015-01-01

    Evaluative conditioning (EC) is defined as the change in the evaluation of a conditioned stimulus (CS) due to its pairing with a positive or negative unconditioned stimulus (US). Although several individual studies suggest that EC is unaffected by unreinforced presentations of the CS without the US, a recent meta-analysis indicates that EC effects are less pronounced for post-extinction measurements than post-acquisition measurements. The disparity in research findings suggests that extinction of EC may depend on yet unidentified conditions. In an attempt to uncover these conditions, three experiments (N = 784) investigated the influence of unreinforced post-acquisition CS presentations on EC effects resulting from simultaneous versus sequential pairings and pairings with single versus multiple USs. For all four types of CS-US pairings, EC effects on self-reported evaluations were reduced by unreinforced CS presentations, but only when the CSs had been rated after the initial presentation of CS-US pairings. EC effects on an evaluative priming measure remained unaffected by unreinforced CS presentations regardless of whether the CSs had been rated after acquisition. The results suggest that reduced EC effects resulting from unreinforced CS presentations are due to judgement-related processes during the verbal expression of CS evaluations rather than genuine changes in the underlying evaluative representations.

  9. Meta-dimensional data integration identifies critical pathways for susceptibility, tumorigenesis and progression of endometrial cancer.

    PubMed

    Wei, Runmin; De Vivo, Immaculata; Huang, Sijia; Zhu, Xun; Risch, Harvey; Moore, Jason H; Yu, Herbert; Garmire, Lana X

    2016-08-23

    Endometrial Cancer (EC) is one of the most common female cancers. Genome-wide association studies (GWAS) have been investigated to identify genetic polymorphisms that are predictive of EC risks. Here we utilized a meta-dimensional integrative approach to seek genetically susceptible pathways that may be associated with tumorigenesis and progression of EC. We analyzed GWAS data obtained from Connecticut Endometrial Cancer Study (CECS) and identified the top 20 EC susceptible pathways. To further verify the significance of top 20 EC susceptible pathways, we conducted pathway-level multi-omics analyses using EC exome-Seq, RNA-Seq and survival data, all based on The Cancer Genome Atlas (TCGA) samples. We measured the overall consistent rankings of these pathways in all four data types. Some well-studied pathways, such as p53 signaling and cell cycle pathways, show consistently high rankings across different analyses. Additionally, other cell signaling pathways (e.g. IGF-1/mTOR, rac-1 and IL-5 pathway), genetic information processing pathway (e.g. homologous recombination) and metabolism pathway (e.g. sphingolipid metabolism) are also highly associated with EC risks, diagnosis and prognosis. In conclusion, the meta-dimensional integration of EC cohorts has suggested some common pathways that may be associated from predisposition, tumorigenesis to progression.

  10. QSAR-like models: a potential tool for the selection of PhACs and EDCs for monitoring purposes in drinking water treatment systems--a review.

    PubMed

    Delgado, Luis F; Charles, Philippe; Glucina, Karl; Morlay, Catherine

    2012-12-01

    Recent studies have demonstrated the presence of trace-level pharmaceutically active compounds (PhACs) and endocrine disrupting compounds (EDCs) in a number of finished drinking waters (DWs). Since there is sparse knowledge currently available on the potential effects on human health associated with the chronic exposure to trace levels of these Emerging Contaminants (ECs) through routes such as DW, it is suggested that the most appropriate criterion is a treatment criterion in order to prioritize ECs to be monitored during DW preparation. Hence, only the few ECs showing the lowest removals towards a given DW Treatment (DWT) process would serve as indicators of the overall efficiency of this process and would be relevant for DW quality monitoring. In addition, models should be developed for estimating the removal of ECs in DWT processes, thereby overcoming the practical difficulties of experimentally assessing each compound. Therefore, the present review has two objectives: (1) to provide an overview of the recent scientific surveys on the occurrence of PhACs and EDCs in finished DWs; and (2) to propose the potential of Quantitative-Structure-Activity-Relationship-(QSAR)-like models to rank ECs found in environmental waters, including parent compounds, metabolites and transformation products, in order to select the most relevant compounds to be considered as indicators for monitoring purposes in DWT systems. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. IGF-1 promotes angiogenesis in endothelial cells/adipose-derived stem cells co-culture system with activation of PI3K/Akt signal pathway.

    PubMed

    Lin, Shiyu; Zhang, Qi; Shao, Xiaoru; Zhang, Tao; Xue, Changyue; Shi, Sirong; Zhao, Dan; Lin, Yunfeng

    2017-12-01

    The aim of this study was to investigate the role of insulin-like growth factor-1 (IGF-1) and crosstalk between endothelial cells (ECs) and adipose-derived stem cells (ASCs) in the process of angiogenesis. A three-dimensional collagen gel used to culture mouse ASCs and mouse ECs in vitro was established. The effects of angiogenesis after exposure to IGF-1 were observed by confocal laser scanning microscopy. Western blotting and qPCR were performed to elucidate the underlying mechanisms. IGF-1 treatment promoted the formation of vessel-like structures and the recruitment of ASCs in the three-dimensional collagen gel. The angiogenic genes and proteins in ECs were up-regulated by IGF-1 and in co-culture. Similar changes in the genes and in the proteins were detected in ASCs after exposure to IGF-1 and co-culture. p-Akt expression levels were high in ECs and ASCs after exposure to IGF-1 and co-culture. IGF-1 and co-culture between cells facilitate the process of angiogenesis via the PI3-kinase/Akt signalling pathway. In ECs, IGF-1 stimulates the expression of angiogenesis-related growth factors with the activation of the PI3-kinase/Akt signalling pathway. Co-cultured ECs exposed to excess VEGF-A and other angiogenesis-related growth factors para-secreted from ASCs exhibit high expression of angiogenesis-related genes and proteins. In ASCs, IGF-1 induces the recruitment and function of ASCs by up-regulating the expression of PDGFB, MMPs and α-SMA. Crosstalk with ECs further facilitates changes in ASCs. © 2017 John Wiley & Sons Ltd.

  12. Transcriptome Analysis of Escherichia coli O157:H7 Exposed to Lysates of Lettuce Leaves ▿

    PubMed Central

    Kyle, Jennifer L.; Parker, Craig T.; Goudeau, Danielle; Brandl, Maria T.

    2010-01-01

    Harvesting and processing of leafy greens inherently cause plant tissue damage, creating niches on leaves that human pathogens can exploit. We previously demonstrated that Escherichia coli O157:H7 (EcO157) multiplies more rapidly on shredded leaves than on intact leaves (M. T. Brandl, Appl. Environ. Microbiol. 74:5285-5289, 2008). To investigate how EcO157 cells adapt to physicochemical conditions in injured lettuce tissue, we used microarray-based whole-genome transcriptional profiling to characterize gene expression patterns in EcO157 after 15- and 30-min exposures to romaine lettuce lysates. Multiple carbohydrate transport systems that have a role in the utilization of substrates known to be prevalent in plant cells were activated in EcO157. This indicates the availability to the human pathogen of a variety of carbohydrates released from injured plant cells that may promote its extensive growth in leaf lysates and, thus, in wounded leaf tissue. In addition, microarray analysis revealed the upregulation of numerous genes associated with EcO157 attachment and virulence, with oxidative stress and antimicrobial resistance (including the OxyR and Mar regulons), with detoxification of noxious compounds, and with DNA repair. Upregulation of oxidative stress and antimicrobial resistance genes in EcO157 was confirmed on shredded lettuce by quantitative reverse transcription-PCR. We further demonstrate that this adaptation to stress conditions imparts the pathogen with increased resistance to hydrogen peroxide and calcium hypochlorite. This enhanced resistance to chlorinated sanitizers combined with increased expression of virulence determinants and multiplication at sites of injury on the leaves may help explain the association of processed leafy greens with outbreaks of EcO157. PMID:20061451

  13. Effect of Ionic Diffusion on Extracellular Potentials in Neural Tissue

    PubMed Central

    Halnes, Geir; Mäki-Marttunen, Tuomo; Keller, Daniel; Pettersen, Klas H.; Andreassen, Ole A.

    2016-01-01

    Recorded potentials in the extracellular space (ECS) of the brain is a standard measure of population activity in neural tissue. Computational models that simulate the relationship between the ECS potential and its underlying neurophysiological processes are commonly used in the interpretation of such measurements. Standard methods, such as volume-conductor theory and current-source density theory, assume that diffusion has a negligible effect on the ECS potential, at least in the range of frequencies picked up by most recording systems. This assumption remains to be verified. We here present a hybrid simulation framework that accounts for diffusive effects on the ECS potential. The framework uses (1) the NEURON simulator to compute the activity and ionic output currents from multicompartmental neuron models, and (2) the electrodiffusive Kirchhoff-Nernst-Planck framework to simulate the resulting dynamics of the potential and ion concentrations in the ECS, accounting for the effect of electrical migration as well as diffusion. Using this framework, we explore the effect that ECS diffusion has on the electrical potential surrounding a small population of 10 pyramidal neurons. The neural model was tuned so that simulations over ∼100 seconds of biological time led to shifts in ECS concentrations by a few millimolars, similar to what has been seen in experiments. By comparing simulations where ECS diffusion was absent with simulations where ECS diffusion was included, we made the following key findings: (i) ECS diffusion shifted the local potential by up to ∼0.2 mV. (ii) The power spectral density (PSD) of the diffusion-evoked potential shifts followed a 1/f2 power law. (iii) Diffusion effects dominated the PSD of the ECS potential for frequencies up to several hertz. In scenarios with large, but physiologically realistic ECS concentration gradients, diffusion was thus found to affect the ECS potential well within the frequency range picked up in experimental recordings. PMID:27820827

  14. Effect of Ionic Diffusion on Extracellular Potentials in Neural Tissue.

    PubMed

    Halnes, Geir; Mäki-Marttunen, Tuomo; Keller, Daniel; Pettersen, Klas H; Andreassen, Ole A; Einevoll, Gaute T

    2016-11-01

    Recorded potentials in the extracellular space (ECS) of the brain is a standard measure of population activity in neural tissue. Computational models that simulate the relationship between the ECS potential and its underlying neurophysiological processes are commonly used in the interpretation of such measurements. Standard methods, such as volume-conductor theory and current-source density theory, assume that diffusion has a negligible effect on the ECS potential, at least in the range of frequencies picked up by most recording systems. This assumption remains to be verified. We here present a hybrid simulation framework that accounts for diffusive effects on the ECS potential. The framework uses (1) the NEURON simulator to compute the activity and ionic output currents from multicompartmental neuron models, and (2) the electrodiffusive Kirchhoff-Nernst-Planck framework to simulate the resulting dynamics of the potential and ion concentrations in the ECS, accounting for the effect of electrical migration as well as diffusion. Using this framework, we explore the effect that ECS diffusion has on the electrical potential surrounding a small population of 10 pyramidal neurons. The neural model was tuned so that simulations over ∼100 seconds of biological time led to shifts in ECS concentrations by a few millimolars, similar to what has been seen in experiments. By comparing simulations where ECS diffusion was absent with simulations where ECS diffusion was included, we made the following key findings: (i) ECS diffusion shifted the local potential by up to ∼0.2 mV. (ii) The power spectral density (PSD) of the diffusion-evoked potential shifts followed a 1/f2 power law. (iii) Diffusion effects dominated the PSD of the ECS potential for frequencies up to several hertz. In scenarios with large, but physiologically realistic ECS concentration gradients, diffusion was thus found to affect the ECS potential well within the frequency range picked up in experimental recordings.

  15. Prediction of biotransformation products of the fungicide fluopyram by electrochemistry coupled online to liquid chromatography-mass spectrometry and comparison with in vitro microsomal assays.

    PubMed

    Mekonnen, Tessema F; Panne, Ulrich; Koch, Matthias

    2018-04-01

    Biotransformation processes of fluopyram (FLP), a new succinate dehydrogenase inhibitor (SDHI) fungicide, were investigated by electrochemistry (EC) coupled online to liquid chromatography (LC) and electrospray mass spectrometry (ESI-MS). Oxidative phase I metabolite production was achieved using an electrochemical flow-through cell equipped with a boron-doped diamond (BDD) electrode. Structural elucidation and prediction of oxidative metabolism pathways were assured by retention time, isotopic patterns, fragmentation, and accurate mass measurements using EC/LC/MS, LC-MS/MS, and/or high-resolution mass spectrometry (HRMS). The results obtained by EC were compared with conventional in vitro studies by incubating FLP with rat and human liver microsomes (RLM, HLM). Known phase I metabolites of FLP (benzamide, benzoic acid, 7-hydroxyl, 8-hydroxyl, 7,8-dihydroxyl FLP, lactam FLP, pyridyl acetic acid, and Z/E-olefin FLP) were successfully simulated by EC/LC/MS. New metabolites including an imide, hydroxyl lactam, and 7-hydroxyl pyridyl acetic acid oxidative metabolites were predicted for the first time in our study using EC/LC/MS and liver microsomes. We found oxidation by dechlorination to be one of the major metabolism mechanisms of FLP. Thus, our results revealed that EC/LC/MS-based metabolic elucidation was more advantageous on time and cost of analysis and enabled matrix-free detection with valuable information about the mechanisms and intermediates of metabolism processes. Graphical abstract Oxidative metabolism of fluopyram.

  16. Analysis of expressed sequence tags (ESTs) from cocoa (Theobroma cacao L) upon infection with Phytophthora megakarya.

    PubMed

    Naganeeswaran, Sudalaimuthu Asari; Subbian, Elain Apshara; Ramaswamy, Manimekalai

    2012-01-01

    Phytophthora megakarya, the causative agent of cacao black pod disease in West African countries causes an extensive loss of yield. In this study we have analyzed 4 libraries of ESTs derived from Phytophthora megakarya infected cocoa leaf and pod tissues. Totally 6379 redundant sequences were retrieved from ESTtik database and EST processing was performed using seqclean tool. Clustering and assembling using CAP3 generated 3333 non-redundant (907 contigs and 2426 singletons) sequences. The primary sequence analysis of 3333 non-redundant sequences showed that the GC percentage was 42.7 and the sequence length ranged from 101 - 2576 nucleotides. Further, functional analysis (Blast, Interproscan, Gene ontology and KEGG search) were executed and 1230 orthologous genes were annotated. Totally 272 enzymes corresponding to 114 metabolic pathways were identified. Functional annotation revealed that most of the sequences are related to molecular function, stress response and biological processes. The annotated enzymes are aldehyde dehydrogenase (E.C: 1.2.1.3), catalase (E.C: 1.11.1.6), acetyl-CoA C-acetyltransferase (E.C: 2.3.1.9), threonine ammonia-lyase (E.C: 4.3.1.19), acetolactate synthase (E.C: 2.2.1.6), O-methyltransferase (E.C: 2.1.1.68) which play an important role in amino acid biosynthesis and phenyl propanoid biosynthesis. All this information was stored in MySQL database management system to be used in future for reconstruction of biotic stress response pathway in cocoa.

  17. House hold unit for the treatment of fluoride, iron, arsenic and microorganism contaminated drinking water.

    PubMed

    Dhadge, Vijaykumar L; Medhi, Chitta Ranjan; Changmai, Murchana; Purkait, Mihir Kumar

    2018-05-01

    A first of its kind hybrid electrocoagulation-filtration prototype unit was fabricated for the removal of fluoride, iron, arsenic and microorganisms contaminated drinking water. The unit comprised of 3 chambers, chamber A consisting of an inlet for the water to be treated and an outlet for the treated water along with one block of aluminum electrodes. Chamber B consisted of ceramic membrane filtration assembly at the bottom over a metallic support which filters the flocs so produced in chamber A and chamber C consisting of space to collect the treated water. Operating parameters were maintained as current density of 625 A m -2 and an electrode distance of 0.005 m. Contaminated drinking water containing mixture of fluoride (10 mg L -1 ), iron (25 mg L -1 ), arsenic (200 μg L -1 ) and microorganisms (35 CFU ml -1 ) was used for the experiment. A removal of 98.74%, 95.65%, 93.2% and 100% were obtained for iron, arsenic, fluoride and microorganisms, respectively. The apparatus and method made it possible to efficiently treat contaminated drinking water to produce drinkable water as per WHO specification. By-products obtained from the electrocoagulation bath were analyzed using SEM, EDX and XRD and explained. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Comparing long term impact on ovarian reserve between laparoscopic ovarian cystectomy and open laprotomy for ovarian endometrioma

    PubMed Central

    2013-01-01

    Objective To compare the long term impact on ovarian reserve between laparoscopic ovarian cystectomy with bipolar electrocoagulation and laparotomic cystectomy with suturing for ovarian endometrotic cyst. Patient and method(s) 121 patients with benign ovarian endometroitic cysts were randomised to either laparoscopic ovarian cystectomy using bipolar electrocoagulation (61 patients) or laparotomic ovarian cystectomy using sutures (60 patients). Serum follicle-stimulating hormone, Antimullerian hormon, Basal antral follicle Count, mean ovarian diameter, and ovarian stromal blood flow velocity were measured at 6, 12 and 18 months after surgery and compared in both groups. Result(s) A statistically significant increase of serum FSH was found in the laproscopic bipolar group at 6-, 12 and 18-month postoperativly compared to open laparotomy suture group. Also, a statistically significant decrease of the mean AMH value occurred in laproscopic bipolar group at 6-, 12 and 18-month follow- up compared to open laparotomy suture group. Basal antral follicle number, mean ovarian diameter and peak systolic velocity were significantly decreased during the 6-, 12,18 -month follow-up in laproscopic bipolar group compared to open laparotomy suture group. Conclusion(s) After laproscopic ovarian cystecomy for endometrioma all pareameter of ovarian reseve are significantly decreased on long term follow up as compared to open laprotomy. PMID:24180348

  19. Mineralizing urban net-zero water treatment: Phase II field ...

    EPA Pesticide Factsheets

    Net-zero water (NZW) systems, or water management systems achieving high recycling rates and low residuals generation so as to avoid water import and export, can also conserve energy used to heat and convey water, while economically restoring local eco-hydrology. However, design and operating experience are extremely limited. The objective of this paper is to present the results of the second phase of operation of an advanced oxidation-based NZW pilot system designed, constructed, and operated for a period of two years, serving an occupied four-person apartment. System water was monitored, either continuously or thrice daily, for routine water quality parameters, minerals, and MicroTox® in-vitro toxicity, and intermittently for somatic and male-specific coliphage, adenovirus, Cryptosporidium, Giardia, emerging organic constituents (non-quantitative), and the Florida drinking water standards. All 115 drinking water standards with the exception of bromate were met in this phase. Neither virus nor protozoa were detected in the treated water, with the exception of measurement of adenovirus genome copies attributed to accumulation of inactive genetic material in hydraulic dead zones. Chemical oxygen demand was mineralized to 90% in treatment. Total dissolved solids were maintained at ∼500 mg/L at steady state, partially through aerated aluminum electrocoagulation. Bromate accumulation is projected to be controlled by aluminum electrocoagulation with separate dispo

  20. The effect of bipolar electrocoagulation during ovarian cystectomy on ovarian reserve: a systematic review.

    PubMed

    Pergialiotis, Vasilios; Prodromidou, Anastasia; Frountzas, Maximos; Bitos, Konstantinos; Perrea, Despina; Doumouchtsis, Stergios K

    2015-11-01

    The aim of the present systematic review was to study the effect of bipolar electrocoagulation during ovarian cystectomy on ovarian reserve. We searched Medline (1966-2015), Scopus (2004-2015), ClinicalTrials.gov (2008-2015), and Cochrane Central Register (CENTRAL) databases along with reference lists of electronically retrieved studies. The levels of antimullerian hormone (AMH) and antral follicle count (AFC) at 1, 3, 6, and 12 months following the excision of the benign ovarian cyst were defined as primary outcomes. Eight studies were finally included in our systematic review, which recruited 545 women. A metaanalysis was precluded because of significant heterogeneity in the methodological characteristics of the included studies. Data from the included studies suggest that the use of bipolar coagulation compared with ovarian sutures seems to result in significantly lower AMH and AFC during the first 3 months following the excision of the ovarian cyst. Two studies reported that this effect seems to persist at 6 and 12 months postoperatively. Bipolar electrodiathermy seems to be accompanied by increased damage to ovarian reserve, which is indicated by the lower levels of AMH and AFC. However, definitive results are precluded because of the significant heterogeneity of included studies and the potential bias. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Encoding instructions and stimulus presentation in local environmental context-dependent memory studies.

    PubMed

    Markopoulos, G; Rutherford, A; Cairns, C; Green, J

    2010-08-01

    Murnane and Phelps (1993) recommend word pair presentations in local environmental context (EC) studies to prevent associations being formed between successively presented items and their ECs and a consequent reduction in the EC effect. Two experiments were conducted to assess the veracity of this assumption. In Experiment 1, participants memorised single words or word pairs, or categorised them as natural or man made. Their free recall protocols were examined to assess any associations established between successively presented items. Fewest associations were observed when the item-specific encoding task (i.e., natural or man made categorisation of word referents) was applied to single words. These findings were examined further in Experiment 2, where the influence of encoding instructions and stimulus presentation on local EC dependent recognition memory was examined. Consistent with recognition dual-process signal detection model predictions and findings (e.g., Macken, 2002; Parks & Yonelinas, 2008), recollection sensitivity, but not familiarity sensitivity, was found to be local EC dependent. However, local EC dependent recognition was observed only after item-specific encoding instructions, irrespective of stimulus presentation. These findings and the existing literature suggest that the use of single word presentations and item-specific encoding enhances local EC dependent recognition.

  2. A composite model of the human postcapillary venule for investigation of microvascular leukocyte recruitment

    PubMed Central

    Lauridsen, Holly M.; Pober, Jordan S.; Gonzalez, Anjelica L.

    2014-01-01

    Neutrophil extravasation occurs across postcapillary venules, structures composed of endothelial cells (ECs), pericytes (PCs), and basement membrane (BM). We constructed composite models of the human postcapillary venule, combining ECs with PCs or PC-deposited BM, to better study this process. Quiescent and tumor necrosis factor α (TNF-α)-activated composites demonstrated in situ-like expression of cadherins, E-selectin, intercellular adhesion molecule 1 (ICAM-1), vascular cell adhesion molecule 1 (VCAM-1), platelet-endothelial cell adhesion molecule 1 (PECAM-1), CD99, and interleukin 8 (IL-8). After TNF-α activation, the ECs supported greater neutrophil adhesion (66.1 vs. 23.7% of input cells) and transmigration (35.1 vs. 7.20% of input cells) than did the PCs, but the composites behaved comparably (no significant difference) to ECs in both assays. TNF-α-activated EC-conditioned medium (CM) increased transmigration across the PCs, whereas TNF-α-activated PC-CM decreased transmigration across the ECs, and culturing on PC-derived BM decreased both adhesion to and transmigration across the ECs. Anti-very late antigen 4 (VLA-4; on neutrophils) inhibited adhesion to TNF-α-activated composites, but not to ECs alone. Anti-CD99 (expressed on all 3 cell types) inhibited transmigration across the composites (14.5% of control) more than across the ECs (39.0% of control), and venular shear stress reduced transmigration across the ECs (17.3% of static) more than across the composites (36.7% of static). These results provide proof of concept that our composite human EC/PC/BM venular construct can reveal new interactions in the inflammatory cascade.—Lauridsen, H. M., Pober, J. S., Gonzalez, A. L. A composite model of the human postcapillary venule for investigation of microvascular leukocyte recruitment. PMID:24297702

  3. Light-regulation of enzyme activity in anacystis nidulans (Richt.).

    PubMed

    Duggan, J X; Anderson, L E

    1975-01-01

    The effect of light on the levels of activity of six enzymes which are light-modulated in higher plants was examined in the photosynthetic procaryot Anacystis nidulans. Ribulose-5-phosphate kinase (EC 2.7.1.19) was found to be light-activated in vivo and dithiothreitol-activated in vitro while glucose-6-phosphate dehydrogenase (EC 1.1.1.49) was light-inactivated and dithiothreitol-inactivated. The enzymes fructose-1,6-diphosphate phosphatase (EC 3.1.3.11), sedoheptulose-1,7-diphosphate phosphatase, NAD- and NADP-linked glyceraldehyde-3-phosphate dehydrogenase (EC 1.2.1.12; EC 1.2.1.13) were not affected by light treatment of the intact algae, but sedoheptulose-diphosphate phosphatase and the glyceraldehyde-3-phosphate dehydrogenases were dithiothreitol-activated in crude extracts. Light apparently controls the activity of the reductive and oxidative pentose phosphate pathway in this photosynthetic procaryot as in higher plants, through a process which probably involves reductive modulation of enzyme activity.

  4. Artificial intelligence in process control: Knowledge base for the shuttle ECS model

    NASA Technical Reports Server (NTRS)

    Stiffler, A. Kent

    1989-01-01

    The general operation of KATE, an artificial intelligence controller, is outlined. A shuttle environmental control system (ECS) demonstration system for KATE is explained. The knowledge base model for this system is derived. An experimental test procedure is given to verify parameters in the model.

  5. Both Trace and Delay Conditioning of Evaluative Responses Depend on Contingency Awareness

    ERIC Educational Resources Information Center

    Kattner, Florian; Ellermeier, Wolfgang; Tavakoli, Paniz

    2012-01-01

    Whereas previous evaluative conditioning (EC) studies produced inconsistent results concerning the role of contingency knowledge, there are classical eye-blink conditioning studies suggesting that declarative processes are involved in trace conditioning but not in delay conditioning. In two EC experiments pairing neutral sounds (conditioned…

  6. Evolving Agents as a Metaphor for the Developing Child

    ERIC Educational Resources Information Center

    Schlesinger, Matthew

    2004-01-01

    The emerging field of Evolutionary Computation (EC), inspired by neo-Darwinian principles (e.g. natural selection, mutation, etc.), offers developmental psychologists a wide array of mathematical tools for simulating ontogenetic processes. In this brief review, I begin by highlighting three of the approaches that EC researchers employ (Artificial…

  7. Exemplary Care as a Mediator of the Effects of Caregiver Subjective Appraisal and Emotional Outcomes

    PubMed Central

    Harris, Grant M.; Durkin, Daniel W.; Allen, Rebecca S.; DeCoster, Jamie; Burgio, Louis D.

    2011-01-01

    Purpose: Exemplary care (EC) is a new construct encompassing care behaviors that warrants further study within stress process models of dementia caregiving. Previous research has examined EC within the context of cognitively intact older adult care recipients (CRs) and their caregivers (CGs). This study sought to expand our knowledge of quality of care by investigating EC within a diverse sample of dementia CGs. Design and Methods: We examined the relation between CG subjective appraisal (daily care bother, burden, and behavioral bother), EC, and CG emotional outcomes (depression and positive aspects of caregiving [PAC]). Specifically, EC was examined as a possible mediator of the effects of CG subjective appraisals on emotional outcomes. Using a bootstrapping method and an SPSS macro developed by Preacher and Hayes (2008 Asymptotic and resampling strategies for assessing and comparing indirect effects in multiple mediator models), we tested the indirect effect of EC on the relation between CG subjective appraisals and CG emotional outcomes. Results: Overall, EC partially mediates the relation between the subjective appraisal variables (daily care bother, burden, and behavioral bother) and PAC. Results for depression were similar except that EC did not mediate the relation between burden and depression. This pattern of results varied by race/ethnicity. Implications: Overall, CGs’ perception of providing EC to individuals with dementia partially explains the relation between subjective appraisal and symptoms of depression and PAC. Results of this study suggest that interventions may benefit from training CGs to engage in EC to improve their emotional outcomes and quality of care. PMID:21350038

  8. Input analysis for two public consultations on the EU Clinical Trials Regulation.

    PubMed

    Langhof, Holger; Lander, Jonas; Strech, Daniel

    2016-09-17

    The European Union's (EU) Clinical Trials Directive was replaced by an EU-Regulation as of 2016. The policy revision process was subject to a formal impact assessment exercised by the European Commission (EC) from 2008 to 2014. Following the EU principles of Good Governance, deliberation with stakeholders was an integral part of this impact assessment and the policy formulation process. Hence, two public consultations (PCs) were held by the EC in 2009 and 2011, respectively. Various stakeholders contributed and submitted their written input to the EC. Though often cited in the further revision process, the input gathered in the PC was not communicated with full transparency and it is unclear how and to what extent the input has been processed and used in the policy formulation. The objective of this study was an analysis of submissions to both PCs in order to systematically present what topics have been discussed and which possible policy options have been raised by the stakeholders. All written submissions publicly available were downloaded from the EC's homepage and assessed for stakeholder characteristics. Thematic text analysis was applied to assess the full text of a random sample of 33% of these submissions. A total of 198 different stakeholders from the EU and the United States of America contributed to one or both of the two PCs. In total, 44 various themes have been addressed that could be clustered under 24 main themes, including the articulation of problems as well as possible policy solutions to face these problems. The two PCs on the Clinical Trials Directive were highly appreciated by the various stakeholders and their input allowed an in-depth view on their particular interests. This input provided a rich source of information for all stakeholders in the field of clinical trials as well as to the EC's impact assessment. Although the EC obviously gathered a large quantity of expert knowledge on practical implications of trials legislation by consulting stakeholders, it remained unclear how this input was used in the development of the new regulation. For the sake of transparency, it is recommended that in future PCs the EC uses better standardized methods for a more transparent analysis and presentation of results.

  9. Ratification vote on taxonomic proposals to the International Committee on Taxonomy of Viruses (2016).

    PubMed

    Adams, Michael J; Lefkowitz, Elliot J; King, Andrew M Q; Harrach, Balázs; Harrison, Robert L; Knowles, Nick J; Kropinski, Andrew M; Krupovic, Mart; Kuhn, Jens H; Mushegian, Arcady R; Nibert, Max; Sabanadzovic, Sead; Sanfaçon, Hélène; Siddell, Stuart G; Simmonds, Peter; Varsani, Arvind; Zerbini, Francisco Murilo; Gorbalenya, Alexander E; Davison, Andrew J

    2016-10-01

    This article lists the changes to virus taxonomy approved and ratified by the International Committee on Taxonomy of Viruses (ICTV) in April 2016.Changes to virus taxonomy (the Universal Scheme of Virus Classification of the International Committee on Taxonomy of Viruses [ICTV]) now take place annually and are the result of a multi-stage process. In accordance with the ICTV Statutes ( http://www.ictvonline.org/statutes.asp ), proposals submitted to the ICTV Executive Committee (EC) undergo a review process that involves input from the ICTV Study Groups (SGs) and Subcommittees (SCs), other interested virologists, and the EC. After final approval by the EC, proposals are then presented for ratification to the full ICTV membership by publication on an ICTV web site ( http://www.ictvonline.org/ ) followed by an electronic vote. The latest set of proposals approved by the EC was made available on the ICTV website by January 2016 ( https://talk.ictvonline.org/files/proposals/ ). A list of these proposals was then emailed on 28 March 2016 to the 148 members of ICTV, namely the EC Members, Life Members, ICTV Subcommittee Members (including the SG chairs) and ICTV National Representatives. Members were then requested to vote on whether to ratify the taxonomic proposals (voting closed on 29 April 2016).

  10. Iron-based catalysts for photocatalytic ozonation of some emerging pollutants of wastewater.

    PubMed

    Espejo, Azahara; Beltrán, Fernando J; Rivas, Francisco J; García-Araya, Juan F; Gimeno, Olga

    2015-01-01

    A synthetic secondary effluent containing an aqueous mixture of emerging contaminants (ECs) has been treated by photocatalytic ozonation using Fe(3+) or Fe3O4 as catalysts and black light lamps as the radiation source. For comparative purposes, ECs have also been treated by ultraviolet radiation (UVA radiation, black light) and ozonation (pH 3 and 7). With the exception of UVA radiation, O3-based processes lead to the total removal of ECs in the mixture. The time taken to achieve complete degradation depends on the oxidation process applied. Ozonation at pH 3 is the most effective technique. The addition of iron based catalysts results in a slight inhibition of the parent compounds degradation rate. However, a positive effect is experienced when measuring the total organic carbon (TOC) and the chemical oxygen demand (COD) removals. Photocatalytic oxidation in the presence of Fe(3+) leads to 81% and 88% of TOC and COD elimination, respectively, compared to only 23% and 29% of TOC and COD removals achieved by single ozonation. The RCT concept has been used to predict the theoretical ECs profiles in the homogeneous photocatalytic oxidation process studied. Treated wastewater effluent was toxic to Daphnia magna when Fe(3+) was used in photocatalytic ozonation. In this case, toxicity was likely due to the ferryoxalate formed in the process. Single ozonation significantly reduced the toxicity of the treated wastewater.

  11. Electrochemistry Combined with LC-HRMS: Elucidating Transformation Products of the Recalcitrant Pharmaceutical Compound Carbamazepine Generated by the White-Rot Fungus Pleurotus ostreatus.

    PubMed

    Seiwert, Bettina; Golan-Rozen, Naama; Weidauer, Cindy; Riemenschneider, Christina; Chefetz, Benny; Hadar, Yitzhak; Reemtsma, Thorsten

    2015-10-20

    Transformation products (TPs) of environmental pollutants must be identified to understand biodegradation processes and reaction mechanisms and to assess the efficiency of treatment processes. The combination of oxidation by an electrochemical cell (EC) with analysis by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) is a rapid approach for the determination and identification of TPs generated by natural microbial processes. Electrochemically generated TPs of the recalcitrant pharmaceutical carbamazepine (CBZ) were used for a target screening for TPs formed by the white-rot fungus Pleurotus ostreatus. EC with LC-HRMS facilitates detection and identification of TPs because the product spectrum is not superimposed with biogenic metabolites and elevated substrate concentrations can be used. A group of 10 TPs formed in the microbial process were detected by target screening for molecular ions, and another 4 were detected by screening on the basis of characteristic fragment ions. Three of these TPs have never been reported before. For CBZ, EC with LC-HRMS was found to be more effective than software tools in defining targets for the screening and faster than nontarget screening alone in TP identification. EC with LC-HRMS may be used to feed MS databases with spectra of possible TPs of larger numbers of environmental contaminants for an efficient target screening.

  12. Emerging contaminants at a closed and an operating landfill in Oklahoma

    USGS Publications Warehouse

    Andrews, William J.; Masoner, Jason R.; Cozzarelli, Isabelle M.

    2012-01-01

    Landfills are the final depositories for a wide range of solid waste from both residential and commercial sources, and therefore have the potential to produce leachate containing many organic compounds found in consumer products such as pharmaceuticals, plasticizers, disinfectants, cleaning agents, fire retardants, flavorings, and preservatives, known as emerging contaminants (ECs). Landfill leachate was sampled from landfill cells of three different age ranges from two landfills in Central Oklahoma. Samples were collected from an old cell containing solid waste greater than 25 years old, an intermediate age cell with solid waste between 16 and 3 years old, and operating cell with solid waste less than 5 years old to investigate the chemical variability and persistence of selected ECs in landfill leachate of differing age sources. Twenty-eight of 69 analyzed ECs were detected in one or more samples from the three leachate sources. Detected ECs ranged in concentration from 0.11 to 114 μg/L and included 4 fecal and plant sterols, 13 household\\industrial, 7 hydrocarbon, and 4 pesticide compounds. Four ECs were solely detected in the oldest leachate sample, two ECs were solely detected in the intermediate leachate sample, and no ECs were solely detected in the youngest leachate sample. Eleven ECs were commonly detected in all three leachate samples and are an indication of the contents of solid waste deposited over several decades and the relative resistance of some ECs to natural attenuation processes in and near landfills.

  13. Characterizing the composition and evolution of and urban particles in Chongqing (China) during summertime

    NASA Astrophysics Data System (ADS)

    Chen, Yang; Yang, Fumo; Mi, Tian; Cao, Junji; Shi, Guangming; Huang, Rujin; Wang, Huanbo; Chen, Jun; Lou, Shengrong; Wang, Qiyuan

    2017-05-01

    Urban particles were investigated using a single particle aerosol mass spectrometer (SPAMS) in Chongqing during the summertime (from 07/05/2014 to 08/06/2014). Chemical composition, mixing state, and atmospheric behavior of urban particles were studied. The major particle types include ECOC (Elemental-Carbon-Organic-Carbon 20.6%), OC (20.1%), KSec (K-Secondary) (13.3%), BB (Biomass burning, 11.9%), NaK (sodium-potassium-rich, 7.3%), Al-rich (4.0%), Fe-rich (3.2%), Ca-rich (1.4%), Ca-EC (1.6%), and NaKPb (0.5%). EC, ECOC, OC, and Ca-EC were prevalent in the condensation mode (< 0.7 μm), while KSec, EC, NaK were significant in both the droplet mode (0.7-1.1 μm) and coarse mode. Increases in aged groups such as EC, KSec, and NaK were observed in the afternoon. Case studies suggested that wet scavenging (rain) rates of different single particle types followed an order of NaKPb > Fe-rich > EC > Ca-EC > Ca-rich > KSec > OC > NaK > ECOC > Al-rich > BB. Increased number fraction of EC and KSec were correlated with the increase of odd oxygen (Ox = O3 + NO2). EC, OC, and ECOC were enriched at higher relative humidity. The findings of this study on the mixing state, temporal variation, processing, and evolution of single particles provide new insight into the atmospheric behavior and impacts of urban particles.

  14. CD146(+) cells are essential for kidney vasculature development.

    PubMed

    Halt, Kimmo J; Pärssinen, Heikki E; Junttila, Sanna M; Saarela, Ulla; Sims-Lucas, Sunder; Koivunen, Peppi; Myllyharju, Johanna; Quaggin, Susan; Skovorodkin, Ilya N; Vainio, Seppo J

    2016-08-01

    The kidney vasculature is critical for renal function, but its developmental assembly mechanisms remain poorly understood and models for studying its assembly dynamics are limited. Here, we tested whether the embryonic kidney contains endothelial cells (ECs) that are heterogeneous with respect to VEGFR2/Flk1/KDR, CD31/PECAM, and CD146/MCAM markers. Tie1Cre;R26R(YFP)-based fate mapping with a time-lapse in embryonic kidney organ culture successfully depicted the dynamics of kidney vasculature development and the correlation of the process with the CD31(+) EC network. Depletion of Tie1(+) or CD31(+) ECs from embryonic kidneys, with either Tie1Cre-induced diphtheria toxin susceptibility or cell surface marker-based sorting in a novel dissociation and reaggregation technology, illustrated substantial EC network regeneration. Depletion of the CD146(+) cells abolished this EC regeneration. Fate mapping of green fluorescent protein (GFP)-marked CD146(+)/CD31(-) cells indicated that they became CD31(+) cells, which took part in EC structures with CD31(+) wild-type ECs. EC network development depends on VEGF signaling, and VEGF and erythropoietin are expressed in the embryonic kidney even in the absence of any external hypoxic stimulus. Thus, the ex vivo embryonic kidney culture models adopted here provided novel ways for targeting renal EC development and demonstrated that CD146(+) cells are critical for kidney vasculature development. Copyright © 2016 International Society of Nephrology. All rights reserved.

  15. Functional interplay between endothelial nitric oxide synthase and membrane type 1–matrix metalloproteinase in migrating endothelial cells

    PubMed Central

    Genís, Laura; Gonzalo, Pilar; Tutor, Antonio S.; Gálvez, Beatriz G.; Martínez-Ruiz, Antonio; Zaragoza, Carlos; Lamas, Santiago; Tryggvason, Karl; Apte, Suneel S.

    2007-01-01

    Nitric oxide (NO) is essential for vascular homeostasis and is also a critical modulator of angiogenesis; however, the molecular mechanisms of NO action during angiogenesis remain elusive. We have investigated the potential relationship between NO and membrane type 1–matrix metalloproteinase (MT1-MMP) during endothelial migration and capillary tube formation. Endothelial NO synthase (eNOS) colocalizes with MT1-MMP at motility-associated structures in migratory human endothelial cells (ECs); moreover, NO is produced at these structures and is released into the medium during EC migration. We have therefore addressed 2 questions: (1) the putative regulation of MT1-MMP by NO in migratory ECs; and (2) the requirement for MT1-MMP in NO-induced EC migration and tube formation. NO upregulates MT1-MMP membrane clustering on migratory human ECs, and this is accompanied by increased degradation of type I collagen substrate. MT1-MMP membrane expression and localization are impaired in lung ECs from eNOS-deficient mice, and these cells also show impaired migration and tube formation in vitro. Inhibition of MT1-MMP with a neutralizing antibody impairs NOinduced tube formation by human ECs, and NO-induced endothelial migration and tube formation are impaired in lung ECs from mice deficient in MT1-MMP. MT1-MMP thus appears to be a key molecular effector of NO during the EC migration and angiogenic processes, and is a potential therapeutic target for NO-associated vascular disorders. PMID:17606763

  16. Widely tunable quantum cascade lasers for spectroscopic sensing

    NASA Astrophysics Data System (ADS)

    Wagner, J.; Ostendorf, R.; Grahmann, J.; Merten, A.; Hugger, S.; Jarvis, J.-P.; Fuchs, F.; Boskovic, D.; Schenk, H.

    2015-01-01

    In this paper recent advances in broadband-tuneable mid-infrared (MIR) external-cavity quantum cascade lasers (EC-QCL) technology are reported as well as their use in spectroscopic process analysis and imaging stand-off detection of hazardous substances, such as explosive and related precursors. First results are presented on rapid scan EC-QCL, employing a custom-made MOEMS scanning grating in Littrow-configuration as wavelength-selective optical feedback element. This way, a scanning rate of 1 kHz was achieved, which corresponds to 2000 full wavelength scans per second. Furthermore, exemplary case studies of EC-QCL based MIR spectroscopy will be presented. These include timeresolved analysis of catalytic reactions in chemical process control, as well as imaging backscattering spectroscopy for the detection of residues of explosives and related precursors in a relevant environment.

  17. Biochar as an electron shuttle for reductive dechlorination of pentachlorophenol by Geobacter sulfurreducens

    PubMed Central

    Yu, Linpeng; Yuan, Yong; Tang, Jia; Wang, Yueqiang; Zhou, Shungui

    2015-01-01

    The reductive dechlorination of pentachlorophenol (PCP) by Geobacter sulfurreducens in the presence of different biochars was investigated to understand how biochars affect the bioreduction of environmental contaminants. The results indicated that biochars significantly accelerate electron transfer from cells to PCP, thus enhancing reductive dechlorination. The promotion effects of biochar (as high as 24-fold) in this process depend on its electron exchange capacity (EEC) and electrical conductivity (EC). A kinetic model revealed that the surface redox-active moieties (RAMs) and EC of biochar (900 °C) contributed to 56% and 41% of the biodegradation rate, respectively. This work demonstrates that biochars are efficient electron mediators for the dechlorination of PCP and that both the EC and RAMs of biochars play important roles in the electron transfer process. PMID:26592958

  18. Electrical and Network Neuronal Properties Are Preferentially Disrupted in Dorsal, But Not Ventral, Medial Entorhinal Cortex in a Mouse Model of Tauopathy

    PubMed Central

    Booth, Clair A.; Ridler, Thomas; Murray, Tracey K.; Ward, Mark A.; de Groot, Emily; Goodfellow, Marc; Phillips, Keith G.; Randall, Andrew D.

    2016-01-01

    The entorhinal cortex (EC) is one of the first areas to be disrupted in neurodegenerative diseases such as Alzheimer's disease and frontotemporal dementia. The responsiveness of individual neurons to electrical and environmental stimuli varies along the dorsal–ventral axis of the medial EC (mEC) in a manner that suggests this topographical organization plays a key role in neural encoding of geometric space. We examined the cellular properties of layer II mEC stellate neurons (mEC-SCs) in rTg4510 mice, a rodent model of neurodegeneration. Dorsoventral gradients in certain intrinsic membrane properties, such as membrane capacitance and afterhyperpolarizations, were flattened in rTg4510 mEC-SCs, while other cellular gradients [e.g., input resistance (Ri), action potential properties] remained intact. Specifically, the intrinsic properties of rTg4510 mEC-SCs in dorsal aspects of the mEC were preferentially affected, such that action potential firing patterns in dorsal mEC-SCs were altered, while those in ventral mEC-SCs were unaffected. We also found that neuronal oscillations in the gamma frequency band (30–80 Hz) were preferentially disrupted in the dorsal mEC of rTg4510 slices, while those in ventral regions were comparatively preserved. These alterations corresponded to a flattened dorsoventral gradient in theta-gamma cross-frequency coupling of local field potentials recorded from the mEC of freely moving rTg4510 mice. These differences were not paralleled by changes to the dorsoventral gradient in parvalbumin staining or neurodegeneration. We propose that the selective disruption to dorsal mECs, and the resultant flattening of certain dorsoventral gradients, may contribute to disturbances in spatial information processing observed in this model of dementia. SIGNIFICANCE STATEMENT The medial entorhinal cortex (mEC) plays a key role in spatial memory and is one of the first areas to express the pathological features of dementia. Neurons of the mEC are anatomically arranged to express functional dorsoventral gradients in a variety of neuronal properties, including grid cell firing field spacing, which is thought to encode geometric scale. We have investigated the effects of tau pathology on functional dorsoventral gradients in the mEC. Using electrophysiological approaches, we have shown that, in a transgenic mouse model of dementia, the functional properties of the dorsal mEC are preferentially disrupted, resulting in a flattening of some dorsoventral gradients. Our data suggest that neural signals arising in the mEC will have a reduced spatial content in dementia. PMID:26758825

  19. Research plan and preliminary results - A field research site for emerging contaminants in Iowa

    USGS Publications Warehouse

    Schnoebelen, Douglas J.; Kolpin, Dana W.; Barber, Larry B.; Furlong, Edward T.; Meyer, Michael; Skopec, M.

    2006-01-01

    Research has recently documented the prevalence of a wide variety of pharmaceuticals and other emerging contaminants (ECs) in streams across the United States. Wastewater treatment plants (WWTPs) have been found to be an important source and collection point of ECs to streams as many ECs are incompletely removed during treatment. To investigate the complex in-stream processes (e.g., dilution, sorption, degradation, dispersion, etc.) that can affect ECs following their input from a WWTP and determining if such input is having an effect on the aquatic ecosystem requires the integration of multi-disciplinary efforts at a carefully selected field site. Preliminary work has identified an 8-km reach of Fourmile Creek in central Iowa as an ideal research site to investigate such important research questions pertaining to ECs. Unique aspects of Fourmile Creek included: (1) it single source effluent-dominated stream, (2) background data document the input of a wide variety of ECs from WWTP discharge, (3) small basin size, (4) relatively simple flow system, (5) background data suggest that undefined processes are taking place decreasing the level of select ECs during stream transport, (6) the WWTP uses a treatment technology (activated sludge) typical of many towns in Iowa and the United States (7) a hydrogeologic setting of a low-gradient, small stream (average discharge less than 1.41 m³/s) in glacial drift is typical of many areas in Iowa and across the Midwest, and (8) the existence of a low-head clam approximately 2 km upstream of the WWTP outfall allowing more accurate "above WWTP" and "below WWTP" comparisons in aquatic ecosystems. Furthermore, the WWTP is scheduled to close by 2011 providing a unique opportunity to determine how stream hydrology, water chemistry and aquatic biota react to the removal of the primary source of flow and ECs in this system. This will allow a novel "before" and "after" assessment not previously available in EC research. Research to date at the site has included installation of a streamflow gauging station, dye-tracing tests (to determine water travel times), Lagrangian water-quality sampling at two flow/water temperature regimes, and sampling for ECs in bed sediment. Selected fish have been collected for analysis and identification. In addition, basic fish community and fish health assessment for different seasons and spawning conditions are being analyzed. The research "framework" is unique at Fourmile Creek for investigating the important question of how ECs are transported through the environment and if the presence of such compounds is having a deleterious effect on aquatic ecosystems.

  20. Interferon-γ converts human microvascular pericytes into negative regulators of alloimmunity through induction of indoleamine 2,3-dioxygenase 1

    PubMed Central

    Liu, Rebecca; Manes, Thomas D.; Qin, Lingfeng; Tietjen, Gregory T.; Broecker, Verena; Fang, Caodi; Xie, Catherine; Chen, Ping-Min; Kirkiles-Smith, Nancy C.; Jane-Wit, Dan; Pober, Jordan S.

    2018-01-01

    Early acute rejection of human allografts is mediated by circulating alloreactive host effector memory T cells (TEM). TEM infiltration typically occurs across graft postcapillary venules and involves sequential interactions with graft-derived endothelial cells (ECs) and pericytes (PCs). While the role of ECs in allograft rejection has been extensively studied, contributions of PCs to this process are largely unknown. This study aimed to characterize the effects and mechanisms of interactions between human PCs and allogeneic TEM. We report that unstimulated PCs, like ECs, can directly present alloantigen to TEM, but while IFN-γ–activated ECs (γ-ECs) show increased ability to stimulate alloreactive T cells, IFN-γ–activated PCs (γ-PCs) instead suppress TEM proliferation but not cytokine production or signaling. RNA sequencing analysis of PCs, γ-PCs, ECs, and γ-ECs reveal induction of indoleamine 2,3-dioxygenase 1 (IDO1) in γ-PCs to significantly higher levels than in γ-ECs that correlates with tryptophan depletion in vitro. Consistently, shRNA knockdown of IDO1 markedly reduces γ-PC–mediated immunoregulatory effects. Furthermore, human PCs express IDO1 in a skin allograft rejection humanized mouse model and in human renal allografts with acute T cell–mediated rejection. We conclude that immunosuppressive properties of human PCs are not intrinsic but instead result from IFN-γ–induced IDO1-mediated tryptophan depletion. PMID:29515027

  1. An in vitro model of a system of electrical potential compensation in extracorporeal circulation.

    PubMed

    Carletti, Umberto; Cattini, Stefano; Lodi, Renzo; Petralia, Antonio; Rovati, Luigi; Zaffe, Davide

    2014-02-01

    Extracorporeal circulation (ECC) in patients undergoing cardiac surgery induces systemic immune-inflammatory reaction that results in increased postoperative morbidity. Many factors are responsible for the adverse response after ECC. The present in vitro study aimed to investigate electric charges (ECs) generated during ECC, to set a device compensating the ECs, and checking its effect on red blood cells (RBC). The electrical signals of blood in ECC were collected by a custom developed low-noise electronic circuit, processed by a digital oscilloscope (DSO) and a dynamic signal analyzer (DSA). The compensation of ECs was performed using a compensation device, injecting a nulling charge into the blood circuit. The compensation effect of the ECs on RBCs was evaluated by scanning electron microscope (SEM). The electrical analysis performed using both the DSO and the DSA confirmed the EC formation during ECC. The notable electric signals recorded in standard ECC circuits substantially nulled once the compensation device was used, thus confirming efficient EC compensation. After two hours of ECC, the SEM non-blended test on human RBC samples highlighted morphological changes in acanthocytes of the normal biconcave-shaped RBC. The outcomes confirm the development of parasitic ECs during ECC and that a suppressor system may decrease the potential damage of ECs. Nevertheless, further studies are ongoing in order to investigate the complex mechanisms related to lymphocytes and platelet morphological and physiological chances during triboelectric charges in ECC.

  2. Astrocytes and extracellular matrix in extrasynaptic volume transmission.

    PubMed

    Vargová, Lýdia; Syková, Eva

    2014-10-19

    Volume transmission is a form of intercellular communication that does not require synapses; it is based on the diffusion of neuroactive substances across the brain extracellular space (ECS) and their binding to extrasynaptic high-affinity receptors on neurons or glia. Extracellular diffusion is restricted by the limited volume of the ECS, which is described by the ECS volume fraction α, and the presence of diffusion barriers, reflected by tortuosity λ, that are created, for example, by fine astrocytic processes or extracellular matrix (ECM) molecules. Organized astrocytic processes, ECM scaffolds or myelin sheets channel the extracellular diffusion so that it is facilitated in a certain direction, i.e. anisotropic. The diffusion properties of the ECS are profoundly influenced by various processes such as the swelling and morphological rebuilding of astrocytes during either transient or persisting physiological or pathological states, or the remodelling of the ECM in tumorous or epileptogenic tissue, during Alzheimer's disease, after enzymatic treatment or in transgenic animals. The changing diffusion properties of the ECM influence neuron-glia interaction, learning abilities, the extent of neuronal damage and even cell migration. From a clinical point of view, diffusion parameter changes occurring during pathological states could be important for diagnosis, drug delivery and treatment. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  3. Enhanced degradation of Orange G by permanganate with the employment of iron anode.

    PubMed

    Bu, Lingjun; Shi, Zhou; Zhou, Shiqing

    2017-01-01

    Iron anode was employed to enhance the degradation of Orange G (OG) by permanganate (EC/KMnO 4 ). Continuously generated Fe 2+ from iron anode facilitated the formation of fresh MnO 2 , which plays a role in catalyzing permanganate oxidation. The EC/KMnO 4 system also showed a better performance to remove OG than Fe 2+ /KMnO 4 , indicating the importance of in situ formed fresh MnO 2 . Besides, the effects of applied current, KMnO 4 dosage, solution pH, and natural organics were evaluated and results demonstrated that high current and oxidant dosage are favorable for OG removal. And the application of iron anode has a promoting effect on the KMnO 4 oxidation over a wide pH range (5.0-9.0), while the Fe 2+ /KMnO 4 process does not. For natural organics, its presence could inhibit OG removal due to its competitive role. And the promoting effect of OG removal by the EC/KMnO 4 process in natural water was confirmed. At last, the EC/KMnO 4 process showed a satisfying performance on the decolorization and mineralization of OG. This study provides a potential technology to enhance permanganate oxidation and broadens the knowledge of azo dye removal.

  4. The Epistemological Chain: Practical Applications in Sports

    ERIC Educational Resources Information Center

    Grecic, David; Collins, Dave

    2013-01-01

    This article highlights the role of personal epistemology in decision-making and proposes the construct of an epistemological chain (EC) to support this process in the domain of sports coaching. First, the EC is outlined using examples from education and other parallel disciplines. What it looks like to sports coaches is then described, and its…

  5. Coaching Conversations in Early Childhood Programs: The Contributions of Coach and Coachee

    ERIC Educational Resources Information Center

    Jayaraman, Gayatri; Marvin, Christine; Knoche, Lisa; Bainter, Sue

    2015-01-01

    Studies to date have linked early childhood (EC) coaching to child, family, and teacher outcomes but have not investigated "what" is happening in a coaching conversation. This exploratory study specifically unpacks nuances associated with the coaching conversation process and associations between the EC coaches' behaviors and coachees'…

  6. Scientific Reasoning and Epistemological Commitments: Coordination of Theory and Evidence among College Science Students

    ERIC Educational Resources Information Center

    Zeineddin, Ava; Abd-El-Khalick, Fouad

    2010-01-01

    Reasoning skills are major contributors to academic and everyday life success. Epistemological commitments (ECs) are believed to underlie reasoning processes and, when considered, could do much in delineating the complex nature of scientific reasoning. This study examined the relationship between ECs and scientific reasoning among college science…

  7. Grouper translationally controlled tumor protein prevents cell death and inhibits the replication of Singapore grouper iridovirus (SGIV).

    PubMed

    Wei, Jingguang; Guo, Minglan; Ji, Huasong; Yan, Yang; Ouyang, Zhengliang; Huang, Xiaohong; Hang, Youhua; Qin, Qiwei

    2012-10-01

    Translationally controlled tumor protein (TCTP) is an important molecule involved in multiple biological processes, such as cell growth, cell cycle progression, malignant transformation, and enhancement of the anti-apoptotic activity. In this study, the TCTP from orange-spotted grouper Epinephelus coioides (Ec-TCTP) was cloned and characterized. The full-length cDNA of Ec-TCTP was comprised of 1057 bp with a 510 bp open reading frame that encodes a putative protein of 170 amino acids. Recombinant Ec-TCTP (rEc-TCTP) was expressed in Escherichia BL21 (DE3) and purified for mouse anti-Ec-TCTP serum preparation. The rEc-TCTP fusion protein was demonstrated to possess antioxidant activity, which conferred resistance to H(2)O(2) damage. Quantitative real-time PCR analysis revealed that Ec-TCTP mRNA is predominately expressed in the liver, and the expression was up-regulated in the liver of grouper after viral challenge with Singapore grouper iridovirus (SGIV). Intracellular localization revealed that Ec-TCTP expression was distributed predominantly in the cytoplasm. Although human TCTP has a role in apoptosis regulation, it is not known if grouper TCTP has any role in apoptosis regulation. Strikingly, grouper TCTP, when overexpressed in fathead minnow (FHM) cells, protected them from cell death induced by cycloheximide (CHX). In addition, overexpressed Ec-TCTP in grouper spleen (GS) cells inhibited the replication of SGIV. These results suggest that Ec-TCTP may play a critical role in their response to SGIV infection, through regulation of a cell death pathway that is common to fish and humans. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. The fate of pharmaceuticals and personal care products (PPCPs), endocrine disrupting contaminants (EDCs), metabolites and illicit drugs in a WWTW and environmental waters.

    PubMed

    Archer, Edward; Petrie, Bruce; Kasprzyk-Hordern, Barbara; Wolfaardt, Gideon M

    2017-05-01

    A large number of emerging contaminants (ECs) are known to persist in surface waters, and create pressure on wastewater treatment works (WWTW) for their effective removal. Although a large database for the levels of these pollutants in water systems exist globally, there is still a lack in the correlation of the levels of these pollutants with possible long-term adverse health effects in wildlife and humans, such as endocrine disruption. The current study detected a total of 55 ECs in WWTW influent surface water, 41 ECs in effluent, and 40 ECs in environmental waters located upstream and downstream of the plant. A list of ECs persisted through the WWTW process, with 28% of all detected ECs removed by less than 50%, and 18% of all ECs were removed by less than 25%. Negative mass balances of some pharmaceuticals and metabolites were observed within the WWTW, suggesting possible back-transformation of ECs during wastewater treatment. Three parental illicit drug compounds were detected within the influent of the WWTW, with concentrations ranging between 27.6 and 147.0 ng L -1 for cocaine, 35.6-120.6 ng L -1 for mephedrone, and 270.9-450.2 ng L -1 for methamphetamine. The related environmental risks are also discussed for some ECs, with particular reference to their ability to disrupt endocrine systems. The current study propose the potential of the pharmaceuticals carbamazepine, naproxen, diclofenac and ibuprofen to be regarded as priority ECs for environmental monitoring due to their regular detection and persistence in environmental waters and their possible contribution towards adverse health effects in humans and wildlife. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Ethics committees and the changed clinical research environment in India in 2016: A perspective!

    PubMed

    Davis, Sanish; Sule, Poonam; Bughediwala, Murtuza; Pandya, Vrunda; Sinha, Shilpi

    2017-01-01

    Institutional and Independent Ethics Committees (ECs) have as their primary mission the protection of human research subjects. The Central Drugs Standard Control Organization has in the period 2013-2016 introduced several new regulations and amendments to existing regulations overseeing the conduct of Research in India. Several of these have direct effect on the functioning of the EC from a review, approval, and oversight mechanism. The Ethics Council of Indian Society for Clinical Research conducted a questionnaire survey among EC members to understand the impact of these changes in their functioning. The domains surveyed included awareness about recent changes/amendments and impacts, serious adverse events (SAEs) and compensation, informed consent and audio-video recording, monitoring and auditing of research, and future working of ECs. Seventy-nine percent of ECs are of the opinion that the new regulations/guidelines will add to their existing burden in the process of review and approval, providing subject protection and research oversight. Even though 68% of ECs stated that they are comfortable with SAE assessment and compensation determination, they state that there is variability in calculation of compensation amount using the formulae. An overwhelming majority (80%) of ECs stated that they were not in favor of centralized EC for providing review, approval, and oversight of clinical studies. Ethics Committees act as local regulator for clinical trials at sites providing Human Subject protection. The survey captures the contemporary issues faced by the ECs and also raises important questions on the ease of doing research, oversight of approved research, and administrative burden on the EC. Recent changes in regulations have on the one hand empowered Ethics committees but brought in challenges in the way that they provide oversight and monitor research carried out at the site.

  10. Downstream effects of hippocampal sharp wave ripple oscillations on medial entorhinal cortex layer V neurons in vitro.

    PubMed

    Roth, Fabian C; Beyer, Katinka M; Both, Martin; Draguhn, Andreas; Egorov, Alexei V

    2016-12-01

    The entorhinal cortex (EC) is a critical component of the medial temporal lobe (MTL) memory system. Local networks within the MTL express a variety of state-dependent network oscillations that are believed to organize neuronal activity during memory formation. The peculiar pattern of sharp wave-ripple complexes (SPW-R) entrains neurons by a very fast oscillation at ∼200 Hz in the hippocampal areas CA3 and CA1 and then propagates through the "output loop" into the EC. The precise mechanisms of SPW-R propagation and the resulting cellular input patterns in the mEC are, however, largely unknown. We therefore investigated the activity of layer V (LV) principal neurons of the medial EC (mEC) during SPW-R oscillations in horizontal mouse brain slices. Intracellular recordings in the mEC were combined with extracellular monitoring of propagating network activity. SPW-R in CA1 were regularly followed by negative field potential deflections in the mEC. Propagation of SPW-R activity from CA1 to the mEC was mostly monosynaptic and excitatory, such that synaptic input to mEC LV neurons directly reflected unit activity in CA1. Comparison with propagating network activity from CA3 to CA1 revealed a similar role of excitatory long-range connections for both regions. However, SPW-R-induced activity in CA1 involved strong recruitment of rhythmic synaptic inhibition and corresponding fast field oscillations, in contrast to the mEC. These differences between features of propagating SPW-R emphasize the differential processing of network activity by each local network of the hippocampal output loop. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Low-dose 6-bromoindirubin-3′-oxime induces partial dedifferentiation of endothelial cells to promote increased neovascularization† (R1)

    PubMed Central

    KOHLER, ERIN E.; BARUAH, JUGAJYOTI; URAO, NORIFUMI; USHIO-FUKAI, MASUKO; FUKAI, TOHRU; CHATTERJEE, ISHITA; WARY, KISHORE K.

    2014-01-01

    Endothelial cell (EC) dedifferentiation in relation to neovascularization is a poorly understood process. In this report we addressed the role of Wnt signaling in the mechanisms of neovascularization in adult tissues. Here, we show that a low-dose of 6-bromoindirubin-3′-oxime (BIO), a competitive inhibitor of Glycogen Synthase Kinase (GSK)-3β, induced the stabilization of β-catenin and its subsequent direct interaction with the transcription factor NANOG in the nucleus of ECs. This event induced loss of VE-cadherin from the adherens junctions, increased EC proliferation accompanied by asymmetric cell division (ACD), and formed cellular aggregates in a hanging drop assays indicating the acquisition of a dedifferentiated state. In a chromatin immunoprecipitation assay, nuclear NANOG protein bound to the NANOG- and VEGFR2-promoters in ECs, and the addition of BIO activated the NANOG-promoter-luciferase reporter system in a cell-based assay. Consequently, NANOG-knockdown decreased BIO-induced NOTCH-1 expression, thereby decreasing cell proliferation, ACD and neovascularization. In a Matrigel plug assay, BIO induced increased neovascularization, secondary to the presence of VEGF. Moreover, in a mouse model of hind limb ischemia, BIO augmented neovascularization that was coupled with increased expression of NOTCH-1 in ECs and increased smooth muscle α-actin (SMA)+ cell recruitment around the neovessels. Thus, these results show the ability of a low-dose of BIO to augment neovascularization secondary to VEGF, a process that was accompanied by a partial dedifferentiation of ECs via β-catenin and the NANOG signaling pathway. PMID:24496925

  12. Escherichia coli and enterococci at beaches in the Grand Traverse Bay, Lake Michigan: Sources, characteristics, and environmental pathways

    USGS Publications Warehouse

    Haack, S.K.; Fogarty, L.R.; Wright, C.

    2003-01-01

    This study quantified Escherichia coli(EC) and enterococci (ENT) in beach waters and dominant source materials, correlated these with ambient conditions, and determined selected EC genotypes and ENT phenotypes. Bathing-water ENT criteria were exceeded more frequently than EC criteria, providing conflicting interpretations of water quality. Dominant sources of EC and ENT were bird feces (108/d/bird), storm drains (107/d), and river water (1011/d); beach sands, shallow groundwater and detritus were additional sources. Beach-water EC genotypes and ENT phenotypes formed clusters with those from all source types, reflecting diffuse inputs. Some ENT isolates had phenotypes similar to those of human pathogens and/or exhibited high-level resistance to human-use antibiotics. EC and ENT concentrations were influenced by collection time and wind direction. There was a 48-72-h lag between rainfall and elevated EC concentrations at three southern shoreline beaches, but no such lag at western and eastern shoreline beaches, reflecting the influence of beach orientation with respect to cyclic (3-5 d) summer weather patterns. In addition to local contamination sources and processes, conceptual or predictive models of Great Lakes beach water quality should consider regional weather patterns, lake hydrodynamics, and the influence of monitoring method variables (time of day, frequency).

  13. Laminin promotes vascular network formation in 3D in vitro collagen scaffolds by regulating VEGF uptake.

    PubMed

    Stamati, Katerina; Priestley, John V; Mudera, Vivek; Cheema, Umber

    2014-09-10

    Angiogenesis is an essential neovascularisation process, which if recapitulated in 3D in vitro, will provide better understanding of endothelial cell (EC) behaviour. Various cell types and growth factors are involved, with vascular endothelial growth factor (VEGF) and its receptors VEGFR1 and VEGFR2 key components. We were able to control the aggregation pattern of ECs in 3D collagen hydrogels, by varying the matrix composition and/or having a source of cells signalling angiogenic proteins. These aggregation patterns reflect the different developmental pathways that ECs take to form different sized tubular structures. Cultures with added laminin and thus increased expression of α6 integrin showed a significant increase (p<0.05) in VEGFR2 positive ECs and increased VEGF uptake. This resulted in the end-to-end network aggregation of ECs. In cultures without laminin and therefore low α6 integrin expression, VEGFR2 levels and VEGF uptake were significantly lower (p<0.05). These ECs formed contiguous sheets, analogous to the 'wrapping' pathway in development. We have identified a key linkage between integrin expression on ECs and their uptake of VEGF, regulated by VEGFR2, resulting in different aggregation patterns in 3D. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Additive effect on reductive decomposition and binding of carbonate-based solvent toward solid electrolyte interphase formation in lithium-ion battery.

    PubMed

    Ushirogata, Keisuke; Sodeyama, Keitaro; Okuno, Yukihiro; Tateyama, Yoshitaka

    2013-08-14

    The solid-electrolyte interphase (SEI) formed through the reductive decomposition of solvent molecules plays a crucial role in the stability and capability of a lithium-ion battery (LIB). Here we investigated the effects of adding vinylene carbonate (VC) to ethylene carbonate (EC) solvent, a typical electrolyte in LIBs, on the reductive decomposition. We focused on both thermodynamics and kinetics of the possible processes and used density functional theory-based molecular dynamics with explicit solvent and Blue-moon ensemble technique for the free energy change. We considered Li(+) in only EC solvent (EC system) and in EC solvent with a VC additive (EC/VC system) to elucidate the additive effects. In addition to clarifying the equilibrium properties, we evaluated the free energy changes along several EC or VC decomposition pathways under one-electron (1e) reduction condition. Two-electron (2e) reduction and attacks of anion radicals to intact molecules were also examined. The present results completely reproduce the gaseous products observed in the experiments. We also found a new mechanism involving the VC additive: the VC additive preferentially reacts with the EC anion radical to suppress the 2e reduction of EC and enhance the initial SEI formation, contrary to the conventional scenario in which VC additive is sacrificially reduced and its radical oligomerization becomes the source of SEI. Because our mechanism needs only 1e reduction, the irreversible capacity at the SEI formation will decrease, which is also consistent with the experimental observations. These results reveal the primary role of VC additive in the EC solvent.

  15. Determinants of the Spatial Distributions of Elemental Carbon and Particulate Matter in Eight Southern Californian Communities

    PubMed Central

    Urman, Robert; Gauderman, James; Fruin, Scott; Lurmann, Fred; Liu, Feifei; Hosseini, Reza; Franklin, Meredith; Avol, Edward; Penfold, Bryan; Gilliland, Frank; Brunekreef, Bert; McConnell, Rob

    2014-01-01

    Emerging evidence indicates that near-roadway pollution (NRP) in ambient air has adverse health effects. However, specific components of the NRP mixture responsible for these effects have not been established. A major limitation for health studies is the lack of exposure models that estimate NRP components observed in epidemiological studies over fine spatial scale of tens to hundreds of meters. In this study, exposure models were developed for fine-scale variation in biologically relevant elemental carbon (EC). Measurements of particulate matter (PM) and EC less than 2.5 μm in aerodynamic diameter (EC2.5) and of PM and EC of nanoscale size less than 0.2 μm were made at up to 29 locations in each of eight Southern California Children's Health Study communities. Regression-based prediction models were developed using a guided forward selection process to identify traffic variables and other pollutant sources, community physical characteristics and land use as predictors of PM and EC variation in each community. A combined eight-community model including only CALINE4 near-roadway dispersion-estimated vehicular emissions accounting for distance, distance-weighted traffic volume, and meteorology, explained 51% of the EC0.2 variability. Community-specific models identified additional predictors in some communities; however, in most communities the correlation between predicted concentrations from the eight-community model and observed concentrations stratified by community were similar to those for the community-specific models. EC2.5 could be predicted as well as EC0.2. EC2.5 estimated from CALINE4 and population density explained 53% of the within-community variation. Exposure prediction was further improved after accounting for between-community heterogeneity of CALINE4 effects associated with average distance to Pacific Ocean shoreline (to 61% for EC0.2) and for regional NOx pollution (to 57% for EC2.5). PM fine spatial scale variation was poorly predicted in both size fractions. In conclusion, models of exposure that include traffic measures such as CALINE4 can provide useful estimates for EC0.2 and EC2.5 on a spatial scale appropriate for health studies of NRP in selected Southern California communities. PMID:25313293

  16. Main factors determining bioerosion patterns on rocky cliffs in a drowned valley estuary in the Colombian Pacific (Eastern Tropical Pacific)

    NASA Astrophysics Data System (ADS)

    Cobo-Viveros, Alba Marina; Cantera-Kintz, Jaime Ricardo

    2015-10-01

    Bioerosion is an important process that destroys coastal rocks in the tropics. However, the rates at which this process occurs, the organisms involved, and the dynamics of rocky cliffs in tropical latitudes have been less studied than in temperate and subtropical latitudes. To contribute to the knowledge of the bioerosion process in rocky cliffs on the Pacific coast of Colombia (Eastern Tropical Pacific) we compared: 1) boring volume, 2) grain size distribution of the rocks, and 3) rock porosity, across three tidal zones of two cliffs with different wave exposure; these factors were related to the bioeroding community found. We observed that cliffs that were not exposed to wave action (IC, internal cliffs) exhibited high percentages of clays in their grain size composition, and a greater porosity (47.62%) and perforation (15.86%) than exposed cliffs (EC, external cliffs). However, IC also exhibited less diversity and abundance of bioeroding species (22 species and 314 individuals, respectively) compared to the values found in EC (41.11%, 14.34%, 32 and 491, respectively). The most abundant bioeroders were Petrolisthes zacae in IC and Pachygrapsus transversus in EC. Our findings show that the tidal zone is the common factor controlling bioerosion on both cliffs; in addition to the abundance of bioeroders on IC and the number of bioeroding species on EC. The integration of geology, sedimentology, and biology allows us to obtain a more comprehensive view of the patterns and trends in the process of bioerosion.

  17. Effects of design parameters and puff topography on heating coil temperature and mainstream aerosols in electronic cigarettes

    NASA Astrophysics Data System (ADS)

    Zhao, Tongke; Shu, Shi; Guo, Qiuju; Zhu, Yifang

    2016-06-01

    Emissions from electronic cigarettes (ECs) may contribute to both indoor and outdoor air pollution and the number of users is increasing rapidly. ECs operate based on the evaporation of e-liquid by a high-temperature heating coil. Both puff topography and design parameters can affect this evaporation process. In this study, both mainstream aerosols and heating coil temperature were measured concurrently to study the effects of design parameters and puff topography. The heating coil temperatures and mainstream aerosols varied over a wide range across different brands and within same brand. The peak heating coil temperature and the count median diameter (CMD) of EC aerosols increased with a longer puff duration and a lower puff flow rate. The particle number concentration was positively associated with the puff duration and puff flow rate. These results provide a better understanding of how EC emissions are affected by design parameters and puff topography and emphasize the urgent need to better regulate EC products.

  18. Using confirmatory factor analysis to understand executive control in preschool children: sources of variation in emergent mathematic achievement

    PubMed Central

    Bull, Rebecca; Espy, Kimberly Andrews; Wiebe, Sandra A.; Sheffield, Tiffany D.; Nelson, Jennifer Mize

    2010-01-01

    Latent variable modeling methods have demonstrated utility for understanding the structure of executive control (EC) across development. These methods are utilized to better characterize the relation between EC and mathematics achievement in the preschool period, and to understand contributing sources of individual variation. Using the sample and battery of laboratory tasks described in Wiebe, Espy and Charak (2008), latent EC was related strongly to emergent mathematics achievement in preschool, and was robust after controlling for crystallized intellectual skills. The relation between crystallized skills and emergent mathematics differed between girls and boys, although the predictive association between EC and mathematics did not. Two dimensions of the child’s social environment contributed to mathematics achievement: social network support through its relation to EC and environmental stressors through its relation with crystallized skills. These findings underscore the need to examine the dimensions, mechanisms, and individual pathways that influence the development of early competence in basic cognitive processes that underpin early academic achievement. PMID:21676089

  19. DOD Electronic Commerce (EC)/Electronic Data Interchange (EDI) in contracting report

    NASA Astrophysics Data System (ADS)

    1993-12-01

    Use of Electronic Commerce (EC)/Electronic Data Interchange (EDI) to support Department of Defense (DoD) procurement processes has been under consideration for some time. A 1988 Deputy Secretary of Defense memo calls for maximum use of EDI, based on 10 years of DoD EDI investigation and experiments. In 1990, Defense Management Review Decision 941 stated, 'The strategic goal of DoD's current efforts is to provide the department with the capability to initiate, conduct, and maintain its external business related transactions and internal logistics, contracting, and financial activities without requiring the use of hard copy media.' The EC in Contracting PAT membership reflected a broad cross section of Military Services and Defense Agencies working on a full-time basis for 60 days. The diversity of the EC in Contracting PAT ensured that the needs and concerns of all DoD components were addressed during the creation of the report. The resultant plan, therefore, represents a comprehensive approach for implementing EC throughout the DoD.

  20. Design of elliptical-core mode-selective photonic lanterns with six modes for MIMO-free mode division multiplexing systems.

    PubMed

    Sai, Xiaowei; Li, Yan; Yang, Chen; Li, Wei; Qiu, Jifang; Hong, Xiaobin; Zuo, Yong; Guo, Hongxiang; Tong, Weijun; Wu, Jian

    2017-11-01

    Elliptical-core few mode fiber (EC-FMF) is used in a mode division multiplexing (MDM) transmission system to release multiple-input-multiple-output (MIMO) digital-signal-processing, which reduces the cost and the complexity of the receiver. However, EC-FMF does not match with conventional multiplexers/de-multiplexers (MUXs/DeMUXs) such as a photonic lantern, leading to extra mode coupling loss and crosstalk. We design elliptical-core mode-selective photonic lanterns (EC-MSPLs) with six modes, which can match well with EC-FMF in MIMO-free MDM systems. Simulation of the EC-MSPL using the beam propagation method was demonstrated employing a combination of either step-index or graded-index fibers with six different sizes of cores, and the taper transition length of 8 cm or 4 cm. Through numerical simulations and optimizations, both types of photonic lanterns can realize low loss transmission and low crosstalk of below -20.0  dB for all modes.

  1. Using confirmatory factor analysis to understand executive control in preschool children: sources of variation in emergent mathematic achievement.

    PubMed

    Bull, Rebecca; Espy, Kimberly Andrews; Wiebe, Sandra A; Sheffield, Tiffany D; Nelson, Jennifer Mize

    2011-07-01

    Latent variable modeling methods have demonstrated utility for understanding the structure of executive control (EC) across development. These methods are utilized to better characterize the relation between EC and mathematics achievement in the preschool period, and to understand contributing sources of individual variation. Using the sample and battery of laboratory tasks described in Wiebe, Espy and Charak (2008), latent EC was related strongly to emergent mathematics achievement in preschool, and was robust after controlling for crystallized intellectual skills. The relation between crystallized skills and emergent mathematics differed between girls and boys, although the predictive association between EC and mathematics did not. Two dimensions of the child 's social environment contributed to mathematics achievement: social network support through its relation to EC and environmental stressors through its relation with crystallized skills. These findings underscore the need to examine the dimensions, mechanisms, and individual pathways that influence the development of early competence in basic cognitive processes that underpin early academic achievement. © 2010 Blackwell Publishing Ltd.

  2. Exemplary Care as a Mediator of the Effects of Caregiver Subjective Appraisal and Emotional Outcomes

    ERIC Educational Resources Information Center

    Harris, Grant M.; Durkin, Daniel W.; Allen, Rebecca S.; DeCoster, Jamie; Burgio, Louis D.

    2011-01-01

    Purpose: Exemplary care (EC) is a new construct encompassing care behaviors that warrants further study within stress process models of dementia caregiving. Previous research has examined EC within the context of cognitively intact older adult care recipients (CRs) and their caregivers (CGs). This study sought to expand our knowledge of quality of…

  3. Stress Response Recruits the Hippocampal Endocannabinoid System for the Modulation of Fear Memory

    ERIC Educational Resources Information Center

    Alvares, Lucas de Oliveira; Engelke, Douglas Senna; Diehl, Felipe; Scheffer-Teixeira, Robson; Haubrich, Josue; Cassini, Lindsey de Freitas; Molina, Victor Alejandro; Quillfeldt, Jorge Alberto

    2010-01-01

    The modulation of memory processes is one of the several functions of the endocannabinoid system (ECS) in the brain, with CB1 receptors highly expressed in areas such as the dorsal hippocampus. Experimental evidence suggested an important role of the ECS in aversively motivated memories. Similarly, glucocorticoids released in response to stress…

  4. Pathways to Problem Behaviors: Chaotic Homes, Parent and Child Effortful Control, and Parenting

    ERIC Educational Resources Information Center

    Valiente, Carlos; Lemery-Chalfant, Kathryn; Reiser, Mark

    2007-01-01

    Guided by Belsky's and Eisenberg, Cumberland, and Spinrad's heuristic models, we tested a process model with hypothesized paths from parents' effortful control (EC) and family chaos to indices of parenting to children's EC, and finally children's externalizing problem behavior. Parents reported on all constructs and children (N = 188; M age = 9.55…

  5. Glial diffusion barriers during aging and pathological states.

    PubMed

    Syková, E

    2001-01-01

    In conclusion, glial cells control not only ECS ionic composition, but also ECS size and geometry. Since ECS ionic and volume changes have been shown to play an important role in modulating the complex synaptic and extrasynaptic signal transmission in the CNS, glial cells may thus affect neuronal interaction, synchronization and neuron-glia communication. As shown in Fig. 2, a link between ionic and volume changes and signal transmission has been proposed as a model for the non-specific feedback mechanism suppressing neuronal activity (Syková, 1997; Ransom, 2000). First, neuronal activity results in the accumulation of [K+]e, which in turn depolarizes glial cells, and this depolarization induces an alkaline shift in glial pHi. Second, the glial cells extrude acid and the resulting acid shift causes a decrease in the neuronal excitability. Because ionic transmembrane shifts are always accompanied by water, this feedback mechanism is amplified by activity-related glial swelling compensated for by ECS volume shrinkage and by increased tortuosity, presumably by the crowding of molecules of the ECS matrix and/or by the swelling of fine glial processes. This, in turn, results in a larger accumulation of ions and other neuroactive substances in the brain due to increased diffusion hinderance in the ECS. Astrocyte hypertrophy, proliferation and swelling influence the size of the ECS volume and tortuosity around neurons, slowing diffusion in the ECS. Their organization may also affect diffusion anisotropy, which could be an underlying mechanism for the specificity of extrasynaptic transmission, including 'cross-talk' between distinct synapses (Barbour and Hausser, 1997; Kullmann and Asztely, 1998). An increased concentration of transmitter released into a synapse (e.g. repetitive adequate stimuli or during high frequency electrical stimulation which induces LTP) results in a significant activation of high-affinity receptors at neighboring synapses. The efficacy of such synaptic cross-talk would be dependent on the extracellular space surrounding the synapses, i.e. on intersynaptic geometry and diffusion parameters. Other recent studies have also suggested an important role for proteoglycans, known to participate in multiple cellular processes, such as axonal outgrowth, axonal branching and synaptogenesis (Hardington and Fosang, 1992; Margolis and Margolis, 1993) that are important for the formation of memory traces. Recent observation of a decrease of fibronectin and chondroitin sulfate proteoglycan staining in the hippocampus of behaviorally impaired aged rats (Syková et al., 1998a,b) supports this hypothesis. It is reasonable to assume that besides neuronal and glial processes, macromolecules of the extracellular matrix contribute to diffusion barriers in the ECS. It is therefore apparent that glial cells play an important role in the local architecture of the CNS and they may also be involved in the modulation of signal transmission, in plastic changes, LTP, LTD and in changes of behavior and memory formation.

  6. Cholesterol-5,6-epoxides: chemistry, biochemistry, metabolic fate and cancer.

    PubMed

    Poirot, Marc; Silvente-Poirot, Sandrine

    2013-03-01

    In the nineteen sixties it was proposed that cholesterol might be involved in the etiology of cancers and cholesterol oxidation products were suspected of being causative agents. Researchers had focused their attention on cholesterol-5,6-epoxides (5,6-ECs) based on several lines of evidence: 1) 5,6-ECs contained an oxirane group that was supposed to confer alkylating properties such as those observed for aliphatic and aromatic epoxides. 2) cholesterol-5,6-epoxide hydrolase (ChEH) was induced in pre-neoplastic lesions of skin from rats exposed to ultraviolet irradiations and ChEH was proposed to be involved in detoxification processes like other epoxide hydrolases. However, 5,6-ECs failed to induce carcinogenicity in rodents which ruled out a potent carcinogenic potential for 5,6-ECs. Meanwhile, clinical studies revealed an anomalous increase in the concentrations of 5,6β-EC in the nipple fluids of patients with pre-neoplastic breast lesions and in the blood of patients with endometrious cancers, suggesting that 5,6-ECs metabolism could be linked with cancer. Paradoxically, ChEH has been recently shown to be totally inhibited by therapeutic concentrations of tamoxifen (Tam), which is one of the main drugs used in the hormonotherapy and the chemoprevention of breast cancers. These data would suggest that the accumulation of 5,6-ECs could represent a risk factor, but we found that 5,6-ECs were involved in the induction of breast cancer cell differentiation and death induced by Tam suggesting a positive role of 5,6-ECs. These observations meant that the biochemistry and the metabolism of 5,6-ECs needed to be extensively studied. We will review the current knowledge and the future direction of 5,6-ECs chemistry, biochemistry, metabolism, and relationship with cancer. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  7. Functional Metagenomics of Escherichia coli O157:H7 Interactions with Spinach Indigenous Microorganisms during Biofilm Formation

    PubMed Central

    Carter, Michelle Q.; Xue, Kai; Brandl, Maria T.; Liu, Feifei; Wu, Liyou; Louie, Jacqueline W.; Mandrell, Robert E.; Zhou, Jizhong

    2012-01-01

    The increase in foodborne outbreaks worldwide attributed to fresh fruit and vegetables suggests that produce may serve as an ecological niche for enteric pathogens. Here we examined the interaction of E. coli O157:H7 (EcO157) with spinach leaf indigenous microorganisms during co-colonization and establishment of a mixed biofilm on a stainless steel surface. Stainless steel surface was selected to mimic the surface of produce-processing equipment, where retention of foodborne pathogens such as EcO157 could serve as a potential source for transmission. We observed a positive effect of spinach-associated microbes on the initial attachment of EcO157, but an antagonistic effect on the EcO157 population at the later stage of biofilm formation. Metagenomic analyses of the biofilm community with the GeoChip revealed an extremely diverse community (gene richness, 23409; Shannon-Weiner index H, 9.55). Presence of EcO157 in the mixed biofilm resulted in a significant decrease in the community α-diversity (t test, P<0.05), indicating a putative competition between the pathogen and indigenous spinach microbes. The decrease in the β-diversity of the EcO157-inoculated biofilm at 48 h (ANOVA, P<0.05) suggested a convergent shift in functional composition in response to EcO157 invasion. The success of EcO157 in the mixed biofilm is likely associated with its metabolic potential in utilizing spinach nutrients: the generation time of EcO157 in spinach lysates at 28°C is ∼ 38 min, which is comparable to that in rich broth. The significant decrease in the abundance of many genes involved in carbon, nitrogen, and phosphorus cycling in the EcO157-inoculated biofilms (t test, P<0.05) further support our conclusion that competition for essential macronutrients is likely the primary interaction between the EcO157 and indigenous spinach-biofilm species. PMID:22957052

  8. Ventricular fibrillation caused by electrocoagulation in monopolar mode during laparoscopic subphrenic mass resection

    PubMed Central

    Yan, Chun-Yan; Wang, Yi-Fan; Yu, Hong

    2010-01-01

    Background Monopolar is usually a safe and effective electrosurgical unit used in laparoscopic general surgery. However, it can cause adverse outcomes and even cardiac arrest. We present a video of laparoscopic subphrenic mass resection using monopolar coagulation during which ventricular fibrillation occurred and from which the patient was successfully resuscitated. Methods Our patient was a 39-year-old man who was admitted to our institution for treatment of a liver mass. The mass was located in the left subphrenic region and was 3.31 cm × 2.7 cm according to B ultrasound. He had had a spleen resection after a car accident 14 years before. He was otherwise healthy and a physical examination was negative. He was scheduled for “laparoscopic exploration, mass resection.” General anesthesia was induced and the operation began. While dissecting the mass from the diaphragm there was some bleeding; monopolar electrocoagulation with 68 W was performed upon which ventricular fibrillation occurred. The operation was stopped and closed-chest compression began immediately. Defibrillation (200-J shock) was performed in 1 min and rhythm returned to sinus. Results The operation was resumed carefully and uneventfully. The patient was sent to the postoperative acute care unit and was extubated 10 min after operation. The patient recovered uneventfully without any signs of permanent cardiac injury and was discharged on postoperative day 3. The final pathology was accessory spleen. Conclusions We present a video of a patient who experienced ventricular fibrillation during laparoscopic surgery which was successfully defibrillated leaving no permanent cardiac injury. We assume the reason for the ventricular fibrillation was the low-frequency leakage current from electrocoagulation which may be conducted by Swan-Ganz catheter to the heart. It is important that we be familiar with the character of electrosurgical unit when performing laparoscopic surgery. We should be careful when using an electrosurgical unit near the cardiac region, especially when the patient has an indwelling catheter. We recommend performing hemostasis in bipolar mode or use an ultrasonic scalpel if bleeding is close to the heart. Also, an easily available defibrillator should be ready for use. Electronic supplementary material The online version of this article (doi:10.1007/s00464-010-1157-0) contains supplementary material, which is available to authorized users. PMID:20589512

  9. Effects of Nickel, Chlorpyrifos and Their Mixture on the Dictyostelium discoideum Proteome

    PubMed Central

    Boatti, Lara; Robotti, Elisa; Marengo, Emilio; Viarengo, Aldo; Marsano, Francesco

    2012-01-01

    Mixtures of chemicals can have additive, synergistic or antagonistic interactions. We investigated the effects of the exposure to nickel, the organophosphate insecticide chlorpyrifos at effect concentrations (EC) of 25% and 50% and their binary mixture (Ec25 + EC25) on Dictyostelium discoideum amoebae based on lysosomal membrane stability (LMS). We treated D. discoideum with these compounds under controlled laboratory conditions and evaluated the changes in protein levels using a two-dimensional gel electrophoresis (2DE) proteomic approach. Nickel treatment at EC25 induced changes in 14 protein spots, 12 of which were down-regulated. Treatment with nickel at EC50 resulted in changes in 15 spots, 10 of which were down-regulated. Treatment with chlorpyrifos at EC25 induced changes in six spots, all of which were down-regulated; treatment with chlorpyrifos at EC50 induced changes in 13 spots, five of which were down-regulated. The mixture corresponding to EC25 of each compound induced changes in 19 spots, 13 of which were down-regulated. The data together reveal that a different protein expression signature exists for each treatment, and that only a few proteins are modulated in multiple different treatments. For a simple binary mixture, the proteomic response does not allow for the identification of each toxicant. The protein spots that showed significant differences were identified by mass spectrometry, which revealed modulations of proteins involved in metal detoxification, stress adaptation, the oxidative stress response and other cellular processes. PMID:23443088

  10. A Complex Extracellular Sphingomyelinase of Pseudomonas aeruginosa Inhibits Angiogenesis by Selective Cytotoxicity to Endothelial Cells

    PubMed Central

    Vasil, Michael L.; Stonehouse, Martin J.; Vasil, Adriana I.; Wadsworth, Sandra J.; Goldfine, Howard; Bolcome, Robert E.; Chan, Joanne

    2009-01-01

    The hemolytic phospholipase C (PlcHR) expressed by Pseudomonas aeruginosa is the original member of a Phosphoesterase Superfamily, which includes phosphorylcholine-specific phospholipases C (PC-PLC) produced by frank and opportunistic pathogens. PlcHR, but not all its family members, is also a potent sphingomyelinase (SMase). Data presented herein indicate that picomolar (pM) concentrations of PlcHR are selectively lethal to endothelial cells (EC). An RGD motif of PlcHR contributes to this selectivity. Peptides containing an RGD motif (i.e., GRGDS), but not control peptides (i.e., GDGRS), block the effects of PlcHR on calcium signaling and cytotoxicity to EC. Moreover, RGD variants of PlcHR (e.g., RGE, KGD) are significantly reduced in their binding and toxicity, but retain the enzymatic activity of the wild type PlcHR. PlcHR also inhibits several EC-dependent in vitro assays (i.e., EC migration, EC invasion, and EC tubule formation), which represent key processes involved in angiogenesis (i.e., formation of new blood vessels from existing vasculature). Finally, the impact of PlcHR in an in vivo model of angiogenesis in transgenic zebrafish, and ones treated with an antisense morpholino to knock down a key blood cell regulator, were evaluated because in vitro assays cannot fully represent the complex processes of angiogenesis. As little as 2 ng/embryo of PlcHR was lethal to ∼50% of EGFP-labeled EC at 6 h after injection of embryos at 48 hpf (hours post-fertilization). An active site mutant of PlcHR (Thr178Ala) exhibited 120-fold reduced inhibitory activity in the EC invasion assay, and 20 ng/embryo elicited no detectable inhibitory activity in the zebrafish model. Taken together, these observations are pertinent to the distinctive vasculitis and poor wound healing associated with P. aeruginosa sepsis and suggest that the potent antiangiogenic properties of PlcHR are worthy of further investigation for the treatment of diseases where angiogenesis contributes pathological conditions (e.g., vascularization of tumors, diabetic retinopathy). PMID:19424430

  11. WQEP - a computer spreadsheet program to evaluate water quality data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liddle, R.G.

    1996-12-31

    A flexible spreadsheet Water Quality Evaluation Program (WQEP) has been developed for mining companies, consultants, and regulators to interpret the results of water quality sampling. In order properly to evaluate hydrologic data, unit conversions and chemical calculations are done, quality control checks are needed, and a complete and up-to-date listing of water quality standards is necessary. This process is time consuming and tends not to be done for every sample. This program speeds the process by allowing the input of up to 115 chemical parameters from one sample. WQEP compares concentrations with EPA primary and secondary drinking water MCLs ormore » MCLG, EPA warmwater and Coldwater acute and chronic aquatic life criteria, irrigation criteria, livestock criteria, EPA human health criteria, and several other categories of criteria. The spreadsheet allows the input of State or local water standards of interest. Water quality checks include: anion/cations, TDS{sub m}/TDS{sub c} (where m=measured and c=calculated), EC{sub m}/EC{sub c}, EC{sub m}/ion sums, TDS{sub c}/EC ratio, TDS{sub m}/EC, EC vs. alkalinity, two hardness values, and EC vs. {Sigma} cations. WQEP computes the dissolved transport index of 23 parameters, computes ratios of 26 species for trend analysis, calculates non-carbonate alkalinity to adjust the bicarbonate concentration, and calculates 35 interpretive formulas (pE, SAR, S.I., unionized ammonia, ionized sulfide HS-, pK{sub x} values, etc.). Fingerprinting is conducted by automatic generation of stiff diagrams and ion histograms. Mass loading calculations, mass balance calculations, conversions of concentrations, ionic strength, and the activity coefficient and chemical activity of 33 parameters is calculated. This program allows a speedy and thorough evaluation of water quality data from metal mines, coal mining, and natural surface water systems and has been tested against hand calculations.« less

  12. Spatial patterns of stream temperatures and electric conductivity in a mesoscale catchment

    NASA Astrophysics Data System (ADS)

    Lieder, Ernestine; Weiler, Markus; Blume, Theresa

    2017-04-01

    Stream temperature and electric conductivity (EC) are both relatively easily measured and can provide valuable information on runoff generation processes and catchment storage.This study investigates the spatial variability of stream temperature and EC in a mesoscale basin. We focus on the mesoscale (sub-catchments and reach scale), and long term (seasonal / annual) stream temperature and EC patterns. Our study basin is the Attert catchment in Luxembourg (288km2), which contains multiple sub-catchments of different geology, topography and land use patterns. We installed 90 stream temperature and EC sensors at sites across the basin in summer 2015. The collected data is complemented by land use and discharge data and an extensive climate data set. Thermal sensitivity was calculated as the slope of daily air temperature-water-temperature regression line and describes the sensitivity of stream temperature to long term environmental change. Amplitude sensitivity was calculated as slope of the daily air and water temperature amplitude regression and describes the short term warming capacity of the stream. We found that groups with similar long term thermal and EC patterns are strongly related to different geological units. The sandstone reaches show the coldest temperatures and lowest annual thermal sensitivity to air temperature. The slate reaches are characterized by comparably low EC and high daily temperature amplitudes and amplitude sensitivity. Furthermore, mean annual temperatures and thermal sensitivities increase exponentially with drainage area, which can be attributed to the accumulation of heat throughout the system. On the reach scale, daily stream temperature fluctuations or sensitivities were strongly influenced by land cover distribution, stream shading and runoff volume. Daily thermal sensitivities were low for headwater streams; peaked for intermediate reaches in the middle of the catchment and then decreased again further downstream with increasing drainage area. Combining spatially distributed time series of stream temperatures and EC with information about geology, landscape and climate provides insight into the underlying hydrological processes and allows for the identification of thermally sensitive regions and reaches.

  13. Risk factors of electrocoagulation syndrome after esophageal endoscopic submucosal dissection

    PubMed Central

    Ma, Dae Won; Youn, Young Hoon; Jung, Da Hyun; Park, Jae Jun; Kim, Jie-Hyun; Park, Hyojin

    2018-01-01

    AIM To investigate post endoscopic submucosal dissection electrocoagulation syndrome (PEECS) of the esophagus. METHODS We analyzed 55 consecutive cases with esophageal endoscopic submucosal dissection for superficial esophageal squamous neoplasms at a tertiary referral hospital in South Korea. Esophageal PEECS was defined as “mild” meeting one of the following criteria without any obvious perforation: fever (≥ 37.8 °C), leukocytosis (> 10800 cells/μL), or regional chest pain more than 5/10 points as rated on a numeric pain intensity scale. The grade of PEECS was determined as “severe” when meet two or more of above criteria. RESULTS We included 51 cases without obvious complications in the analysis. The incidence of mild and severe esophageal PEECS was 47.1% and 17.6%, respectively. Risk factor analysis revealed that resected area, procedure time, and muscle layer exposure were significantly associated with PEECS. In multivariate analysis, a resected area larger than 6.0 cm2 (OR = 4.995, 95%CI: 1.110-22.489, P = 0.036) and muscle layer exposure (OR = 5.661, 95%CI: 1.422-22.534, P = 0.014) were independent predictors of esophageal PEECS. All patients with PEECS had favorable outcomes with conservative management approaches, such as intravenous hydration or antibiotics. CONCLUSION Clinicians should consider the possibility of esophageal PEECS when the resected area exceeds 6.0 cm2 or when the muscle layer exposure is noted. PMID:29563758

  14. Evaluation of pre-treatment technologies for phosphorous removal from drinking water to mitigate membrane biofouling

    NASA Astrophysics Data System (ADS)

    Frolova, M.; Tihomirova, K.; Mežule, L.; Rubulis, J.; Gruškeviča, K.; Juhna, T.

    2017-10-01

    Membranes are widely used for the treatment of various solutions. However, membrane fouling remains the limiting factor for their usage, setting biofouling as the most severe type of it. Therefore, the production of biologically stable water prior to membranes is important. Since lack of phosphorus may hinder the growth of microorganisms, the aim of this research is to evaluate the effect of microbially available phosphorus (MAP) removal via affordable water pre-treatment methods (adsorption, biofiltration, electrocoagulation) on bacterial growth. Four cylindrical reactors were installed at an artificially recharged groundwater station. Further temperature influence and carbon limitation were tested for biofiltration technology. The amount of MAP and total cell count was measured by flow cytometry. The results showed that at lower temperatures electrocoagulation performed the best, resulting in complete MAP removal (detection limit 6.27x10-3μg P l-1). Sorbent demonstrated MAP removal of 70-90%. Biomass did not have any noteworthy results at +8°C, however, at +19°C MAP removal of around 80% was achieved. Main conclusions obtained within this study are: (i) tested technologies effectively eliminate MAP levels; (ii) temperature has a significant effect on MAP removal in a bioreactor, (iii) multi-barrier approach might be necessary for better P limitation that might prolong operating time of a membrane.

  15. Outcome of bipolar electrocoagulation with lesionectomy in the treatment of epilepsy involving eloquent areas.

    PubMed

    Zhai, Feng; Zhou, Jian; Li, Tianfu; Cui, Zhiqiang; Luan, Guoming

    2015-01-01

    We have demonstrated previously that bipolar electrocoagulation on functional cortex (BCFC) is a safe and effective approach for epilepsy involving eloquent areas. Here, we report the results of BCFC with lesionectomy for patients with epileptogenic foci partially overlapping eloquent areas. Forty patients who had been treated with lesionectomy with BCFC were retrospectively reviewed with regard to seizure outcome and neurological deficits. Ten similar patients who had received lesionectomy with multiple subpial transections (MST) were examined as a control group. In the lesionectomy group with BCFC, Engel class I was achieved in 18 (45%) patients, class II in 8 (20%) patients, class III in 8 (20%) patients and class IV in 6 (15%) patients. Five (12.5%) patients developed mild hemiparesis and 1 (2.5%) patient mild sensory dysphasia. In the lesionectomy group with MST, Engel class I was achieved in 3 (30%) patients, class II in 2 (20%) patients, class III in 3 (30%) patients and class IV in 2 (20%) patients. Two (20%) patients developed mild hemiparesis and 1 (10%) patient moderate hemiparesis. All these complications recovered within 1-12 months. Compared with MST, the outcome of BCFC with lesionectomy is similar. But since MST leads to mechanical injury, while BCFC causes thermal injury, the complications of BCFC seem less severe. © 2014 S. Karger AG, Basel.

  16. Autologous osteoblast transplantation, an innovative method of bone defect treatment: role of a tissue and cell bank in the process.

    PubMed

    Olender, E; Brubaker, S; Uhrynowska-Tyszkiewicz, I; Wojtowicz, A; Kaminski, A

    2014-10-01

    The idea of cell treatment of various diseases and medical conditions has become very popular. Some procedures are well established, as is autologous chondrocyte implantation, whereas others are still in the process of early development, laboratory experiments, and some clinical trials. This report is devoted to an example of an emerging cell treatment: bone augmentation with the use of autologous cells and its legal and technical background. Various requirements set by law must be met by tissue banks performing cell seeding of grafts. In Europe, the requirements are described in directives 2004/23/EC, 2006/17/EC, 2006/86/EC, and in the regulation 2007/1394/EC. Revitalization of biostatic allografts gives new, promising tools for creation of functional parts of organs; brings the methodology used in tissue banks closer to tissue engineering; places the enterprise in the mainstream of advanced biotechnology; allows the full potential of tissue allografts; and opens a new, large area for clinical and laboratory research. Cell and tissue processing also have a financial impact on the treatment: it produces additional expenditures. Clinical effectiveness will be the most decisive factor of whether this innovative treatment will be applied in a particular type of medical condition. From a tissue establishment perspective, the most important issue is to develop a procedure that ensures safety for the patient in graft quality terms.

  17. Evaluation of emerging contaminants in a drinking water treatment plant using electrodialysis reversal technology.

    PubMed

    Gabarrón, S; Gernjak, W; Valero, F; Barceló, A; Petrovic, M; Rodríguez-Roda, I

    2016-05-15

    Emerging contaminants (EC) have gained much attention with globally increasing consumption and detection in aquatic ecosystems during the last two decades from ng/L to lower ug/L. The aim of this study was to evaluate the occurrence and removal of pharmaceutically active compounds (PhACs), endocrine disrupting chemicals (EDCs) and related compounds in a Drinking Water Treatment Plant (DWTP) treating raw water from the Mediterranean Llobregat River. The DWTP combined conventional treatment steps with the world's largest electrodialysis reversal (EDR) facility. 49 different PhACs, EDCs and related compounds were found above their limit of quantification in the influent of the DWTP, summing up to a total concentration of ECs between 1600-4200 ng/L. As expected, oxidation using chlorine dioxide and granular activated carbon filters were the most efficient technologies for EC removal. However, despite the low concentration detected in the influent of the EDR process, it was also possible to demonstrate that this process partially removed ionized compounds, thereby constituting an additional barrier against EC pollution in the product. In the product of the EDR system, only 18 out of 49 compounds were quantifiable in at least one of the four experimental campaigns, showing in all cases removals higher than 65% and often beyond 90% for the overall DWTP process. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Endotoxin induces fibrosis in vascular endothelial cells through a mechanism dependent on transient receptor protein melastatin 7 activity.

    PubMed

    Echeverría, Cesar; Montorfano, Ignacio; Hermosilla, Tamara; Armisén, Ricardo; Velásquez, Luis A; Cabello-Verrugio, Claudio; Varela, Diego; Simon, Felipe

    2014-01-01

    The pathogenesis of systemic inflammatory diseases, including endotoxemia-derived sepsis syndrome, is characterized by endothelial dysfunction. It has been demonstrated that the endotoxin lipopolysaccharide (LPS) induces the conversion of endothelial cells (ECs) into activated fibroblasts through endothelial-to-mesenchymal transition mechanism. Fibrogenesis is highly dependent on intracellular Ca2+ concentration increases through the participation of calcium channels. However, the specific molecular identity of the calcium channel that mediates the Ca2+ influx during endotoxin-induced endothelial fibrosis is still unknown. Transient receptor potential melastatin 7 (TRPM7) is a calcium channel that is expressed in many cell types, including ECs. TRPM7 is involved in a number of crucial processes such as the conversion of fibroblasts into activated fibroblasts, or myofibroblasts, being responsible for the development of several characteristics of them. However, the role of the TRPM7 ion channel in endotoxin-induced endothelial fibrosis is unknown. Thus, our aim was to study whether the TRPM7 calcium channel participates in endotoxin-induced endothelial fibrosis. Using primary cultures of ECs, we demonstrated that TRPM7 is a crucial protein involved in endotoxin-induced endothelial fibrosis. Suppression of TRPM7 expression protected ECs from the fibrogenic process stimulated by endotoxin. Downregulation of TRPM7 prevented the endotoxin-induced endothelial markers decrease and fibrotic genes increase in ECs. In addition, TRPM7 downregulation abolished the endotoxin-induced increase in ECM proteins in ECs. Furthermore, we showed that intracellular Ca2+ levels were greatly increased upon LPS challenge in a mechanism dependent on TRPM7 expression. These results demonstrate that TRPM7 is a key protein involved in the mechanism underlying endotoxin-induced endothelial fibrosis.

  19. Platelet factor 4/CXCL4-stimulated human monocytes induce apoptosis in endothelial cells by the release of oxygen radicals.

    PubMed

    Woller, Geske; Brandt, Ernst; Mittelstädt, Jessica; Rybakowski, Christian; Petersen, Frank

    2008-04-01

    The generation of reactive oxygen species (ROS) represents a pivotal element of phagocyte defense against microbial invaders. However, oxidative stress also participates in pathophysiological processes of vascular damage leading to cell death of endothelial cells (EC). Currently, ROS-producing cells involved in this process as well as the corresponding extracellular signals required for their activation are ill-defined. In this study, we investigate the impact of the platelet-derived CXC chemokine platelet factor 4 (PF4/CXCL4) on the interaction of human monocytes and EC. We can show for the first time that PF4-activated monocytes become cytotoxic for EC but not epithelial cells. Cytotoxicity was time- and dose-dependent, and earliest effects were seen after 15 h of culture and at a concentration from 0.125 microM PF4 up. By performing transwell experiments and by using specific inhibitory antibodies, we could show that direct cell contact between effector and target cells, mediated by beta(2)integrins as well as their corresponding ligand ICAM-1, is essential for the cytotoxic effect. Investigations of the cellular mechanisms of cytotoxicity revealed that in the presence of EC, PF4-activated monocytes are capable of releasing high amounts of ROS for more than 2 h following stimulation. This causes programmed cell death in EC, as inhibitors of the NADPH oxidase (diphenyleneiodonium and apocynin) effectively blocked PF4-induced monocyte oxidative burst and protected EC from undergoing apoptosis. Taken together, our data suggest a role for platelet-derived PF4 in oxidative stress-mediated vascular disorders, as observed during atherosclerosis or ischemia/reperfusion injury.

  20. Species turnover (β-diversity) in ectomycorrhizal fungi linked to NH4+ uptake capacity.

    PubMed

    Kranabetter, J M; Hawkins, B J; Jones, M D; Robbins, S; Dyer, T; Li, T

    2015-12-01

    Ectomycorrhizal (EcM) fungal communities may be shaped by both deterministic and stochastic processes, potentially influencing ecosystem development and function. We evaluated community assembly processes for EcM fungi of Pseudotsuga menziesii among 12 sites up to 400 km apart in southwest British Columbia (Canada) by investigating species turnover (β-diversity) in relation to soil nitrogen (N) availability and physical distance. We then examined functional traits for an N-related niche by quantifying net fluxes of NH4+, NO3- and protons on excised root tips from three contrasting sites using a microelectrode ion flux measurement system. EcM fungal communities were well aligned with soil N availability and pH, with no effect of site proximity (distance-decay curve) on species assemblages. Species turnover was significant (β(1/2) = 1.48) along soil N gradients, with many more Tomentella species on high N than low N soils, in contrast to Cortinarius species. Ammonium uptake was greatest in the spring on the medium and rich sites and averaged over 190 nmol/m(2)/s for Tomentella species. The lowest uptake rates of NH4+ were by nonmycorrhizal roots of axenically grown seedlings (10 nmol/m(2)/s), followed by Cortinarius species (60 nmol/m(2)/s). EcM roots from all sites displayed only marginal uptake of nitrate (8.3 nmol/m(2)/s). These results suggest NH4+ uptake capacity is an important functional trait influencing the assembly of EcM fungal communities. The diversity of EcM fungal species across the region arguably provides critical belowground adaptations to organic and inorganic N supply that are integral to temperate rainforest ecology. © 2015 John Wiley & Sons Ltd.

Top