Dong, Jin-yang; Zhang, Gui-xin; Wang, Chang-quan
2012-01-01
As a kind of new electric light source, electrodeless discharge lamps are of long life, low mercury and non-stroboscopic light. The lighting effect of electrodeless discharge lamps depends on the radiation efficiency of 253.7 nm resonance spectra line to a large extent. The influence of cold temperature on 253.7 nm resonance spectra line has been studied experimentally by atomic emission spectral analysis. It was found that the radiation efficiency of 253.7 nm resonance spectra line is distributed in a nearly normal fashion with the variation of cold spot temperature, in other words, there is an optimum cold spot temperature for an electrodeless discharge lamp. At last, the results of experiments were analyzed through gas discharge theory, which offers guidance to the improvement of lighting effect for electrodeless discharge lamps.
Electrodeless discharge lamp is easily started, has high stability
NASA Technical Reports Server (NTRS)
Bell, W. E.; Bloom, A. L.
1966-01-01
Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.
Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp
Borowiec, Joseph Christopher; Cocoma, John Paul; Roberts, Victor David
1998-01-01
An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.
One piece microwave container screens for electrodeless lamps
Turner, Brian; Ury, Michael
1998-01-01
A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. Replacing mesh material by solid metal material as part of the screen unit significantly reduces leakage of microwave energy from the lamp. The solid section has multiple compliant fingers defined therein for engaging the periphery of a flange on the waveguide unit so that a hose clamp can easily secure the screen to the assembly. Screen units of this type having different mesh section configurations can be interchanged in the lamp assembly to produce different respective illumination patterns.
Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference
Simpson, James E.
1999-01-01
An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.
Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference
Simpson, J.E.
1999-06-08
An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.
Inductive tuners for microwave driven discharge lamps
Simpson, James E.
1999-01-01
An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.
Very high efficacy electrodeless high intensity discharge lamps
Johnson, Peter D.
1987-01-01
An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.
Very high efficacy electrodeless high intensity discharge lamps
Johnson, P.D.
1985-10-03
An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.
Horikoshi, Satoshi; Tsuchida, Akihiro; Abe, Masahiko; Ohba, Naoki; Uchida, Masayoshi; Serpone, Nick
2010-01-01
This short article examines the microwave-assisted photolytic disinfection of aqueous solutions contaminated by Bacillus subtilis microorganisms using UV and vacuum-UV radiation emitted from a microwave discharge electrodeless lamp (MDEL), a device containing a Hg/Ar gas-fill that was proposed recently for use in Advanced Oxidation Processes (AOPs). Results of the disinfection are compared with those obtained from UV radiation emitted by a low-pressure electrode Hg lamp and by an excimer lamp. Also examined is the disinfection of B. subtilis aqueous media that contained Au3+ or Ni2+ ions, species often found in the treatment of electroplating wash wastewaters.
Xia, Lan-Yan; Gu, Ding-Hong; Tan, Jing; Dong, Wen-Bo; Hou, Hui-Qi
2008-04-01
The photolysis of simulating low concentration of hydrogen sulfide malodorous gas was studied under UV irradiation emitted by self-made microwave discharge electrodeless lamps (i.e. microwave UV electrodeless mercury lamp (185/253.7 nm) and iodine lamp (178.3/180.1/183/184.4/187.6/206.2 nm)). Experiments results showed that the removal efficiency (eta H2S) of hydrogen sulfide was decreased with increasing initial H2S concentration and increased slightly with gas residence time; H2S removal efficiency was decreased dramatically with enlarged pipe diameter. Under the experimental conditions with pipe diameter of 36 mm, gas flow rate of 0.42 standard l s(-1), eta H2S was 52% with initial H2S concentration of 19.5 mg m(-3) by microwave mercury lamp, the absolute removal amount (ARA) was 4.30 microg s(-1), and energy yield (EY) was 77.3 mg kW h(-1); eta H2S was 56% with initial H2S concentration of 18.9 mg m(-3) by microwave iodine lamp, the ARA was 4.48 microg s(-1), and the EY was 80.5mg kW h(-1). The main photolysis product was confirmed to be SO4(2-) with IC.
NASA Technical Reports Server (NTRS)
Laue, H. H.; Clough, L. G. (Inventor)
1973-01-01
An electrodeless lamp circuit with a coil surrounding a krypton lamp is driven by an RF input source. A coil surrounding a mercury lamp is tapped across the connection of the input central to the krypton-lamp coil. Each coil is connected in parallel with separate capacitors which form resonant circuits at the input frequency.
Lamp bulb with integral reflector
Levin, Izrail; Shanks, Bruce; Sumner, Thomas L.
2001-01-01
An improved electrodeless discharge lamp bulb includes an integral ceramic reflector as a portion of the bulb envelope. The bulb envelope further includes two pieces, a reflector portion or segment is cast quartz ceramic and a light transmissive portion is a clear fused silica. In one embodiment, the cast quartz ceramic segment includes heat sink fins or stubs providing an increased outside surface area to dissipate internal heat. In another embodiment, the quartz ceramic segment includes an outside surface fused to eliminate gas permeation by polishing.
Ta, Na; Hong, Jun; Liu, Tingfeng; Sun, Cheng
2006-11-02
The present study investigates the degradation of atrazine (2-chloro-4-(ethyl amino)-6-isopropyl amino-s-triazine) in aqueous solution by a developed new method, namely by means of a microwave-assisted electrodeless discharge mercury lamp (MW-EDML). An experimental design was conducted to assess the influence of various parameters: pH value, initial concentration, amount of EDML, initial volume and coexisted solvent. Atrazine was degraded completely by EDML in a relatively short time (i.e. t(1/2)=1.2 min for 10 mg/l). Additionally, the identification of main degradation products during atrazine degradation process was conducted by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). This study proposes the degradation mechanism including four possible pathways for atrazine degradation according to the degradation products.
Horikoshi, Satoshi; Sato, Tatsuro; Sakamoto, Kazutami; Abe, Masahiko; Serpone, Nick
2011-07-01
A novel mercury-free Dewar-like (double-walled structure) microwave discharge thermally-insulated electrodeless lamp (MDTIEL) was fabricated and its performance evaluated using the photo-isomerization of trans-urocanic acid (trans-UA) in aqueous media as a test process driven by the emitted UV light when ignited with microwave radiation. The photo-isomerization processes trans-UA → cis-UA and cis-UA → trans-UA were re-visited using light emitted from a conventional high-pressure Hg light source and examined for the influence of UV light irradiance and solution temperature; the temperature dependence of the trans → cis process displayed a negative activation energy, E(a) = -1.3 cal mol(-1). To control the photo-isomerization of urocanic acid from the heat usually dissipated by a microwave discharge electrodeless lamp (single-walled MDEL), it was necessary to suppress the microwave-initiated heat. For comparison, the gas-fill in the MDEL lamp, which typically consists of a mixture of Hg and Ar, was changed to the more eco-friendly N(2) gas in the novel MDTIEL device. The dynamics of the photo-isomerization of urocanic acid driven by the UV wavelengths of the N(2)-MDTIEL light source were compared to those from the more conventional single-walled N(2)-MDEL and Hg/Ar-MDEL light sources, and with those from the Hg lamp used to irradiate, via a fiber optic, the photoreactor located in the wave-guide of the microwave apparatus. The heating efficiency of a solution with the double-walled N(2)-MDTIEL was compared to the efficiency from the single-walled N(2)-MDEL device. Advantages of N(2)-MDTIEL are described from a comparison of the dynamics of the trans-UA → cis-UA process on the basis of unit surface area of the lamp and unit power consumption. The considerably lower temperature on the external surface of the N(2)-MDTIEL light source should make it attractive in carrying out photochemical reactions that may be heat-sensitive such as the photothermochromic urocanic acid system.
Electrodeless-discharge-vapor-lamp-based Faraday anomalous-dispersion optical filter.
Sun, Qinqing; Zhuang, Wei; Liu, Zhiwen; Chen, Jingbiao
2011-12-01
We report an excited-state Faraday anomalous-dispersion optical filter operating on the rubidium 5P(3/2)-5D(5/2) transition (775.9 nm in vacuum) without the use of a pump laser. An electrodeless discharge vapor lamp is employed to replace the Rb vapor cell in a traditional Faraday anomalous-dispersion optical filter system. Atoms can be excited by power rather than a complex frequency-locked pump laser. A proof-of-concept experimental demonstration with a maximum transmission of 1.9% and a filter bandwidth of 650 MHz is presented. © 2011 Optical Society of America
Ai, Zhi-hui; Jiang, Jun-qing; Yang, Peng; Zhou, Tao; Lu, Xiao-hua
2004-07-01
A microwave assisted UV electrodeless discharge lamp system (MW/UV) was used for photo-degradation of 4CP simulated wastewater. In order to evaluate the degradation efficiency of 4CP, UV spectrophotometry and ion chromatography were used for determination of 4CP and Cl- respectively. The degradation rate in MW/UV system was higher than that in the UV system within 120min, which were 52.40% and 21.56% respectively. The degradation efficiency was improved by increasing pH value of the solution, aerating O2 gas, enhancing light intensity, or adding H2O2 oxidant. The degradation of 4CP under MW/UV accords with the first order kinetics equation.
NASA Astrophysics Data System (ADS)
Whiting, Michael; Preston, Barry; Mucklejohn, Stuart; Santos, Monica; Lister, Graeme
2016-09-01
Here we present an investigation into the feasibility of creating a diagnostic tool for obtaining maximum arc temperature measurements within a high pressure electrodeless discharge; utilizing integrating sphere measurements of optically thin lines emitted from mercury atoms within commercially available high pressure mercury lamp arc tubes. The optically thin lines chosen were 577 nm and 1014 nm from a 250 W high pressure mercury lamp operated at various powers. The effective temperature could be calculated by considering the relative intensities of the two optically thin lines and comparison with the theoretical ratio of the temperature dependent power emitted from the lines derived from the atomic spectral data provided by NIST. The calculations gave effective arc temperatures of 5755, 5804 and 5820 K at 200, 225, 250 W respectively. This method was subsequently used as a basis for determining maximum effective arc temperature within microwave-driven electrodeless discharge capsules, with varying mercury content of 6.07, 9.4 and 12.95 mg within 1 × 10-6 m3 giving maximum effective temperatures of 5163, 4768 and 4715 K respectively at 240 W.
Fu, Jie; Xu, Zhen; Li, Qing-Shan; Chen, Song; An, Shu-Qing; Zeng, Qing-Fu; Zhu, Hai-Liang
2010-01-01
A comparative study of treatment of simulated wastewater containing Reactive Red 195 using zero-valent iron/activated carbon (ZVI/AC), microwave discharge electrodeless lamp/sodium hypochlorite (MDEL/NaClO) and the combination of ZVI/AC-MDEL/NaClO was conducted. The preliminary results showed the two steps method of ZVI/AC-MDEL/NaClO had much higher degradation efficiency than both single steps. The final color removal percentage was nearly up to 100% and the chemical oxygen demand reduction percentage was up to approximately 82%. The effects of operational parameters, including initial pH value of simulated wastewater, ZVI/AC ratio and particle size of ZVI were also investigated. In addition, from the discussion of synergistic effect between ZVI/AC and MEDL/NaClO, we found that in the ZVI/AC-MEDL/NaClO process, ZVI/AC could break the azo bond firstly and then MEDL/NaClO degraded the aromatic amine products effectively. Reversing the order would reduce the degradation efficiency.
Lamp method and apparatus using multiple reflections
MacLennan, Donald A.; Turner, Brian; Kipling, Kent
1999-01-01
A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture.
Horikoshi, Satoshi; Tsuchida, Akihiro; Sakai, Hideki; Abe, Masahiko; Sato, Susumu; Serpone, Nick
2009-11-01
A metallic condensing cone that concentrates microwave radiation (equivalent to an optical lens) has been developed and used as part of a system to activate a microwave discharge electrodeless lamp (MDEL) in the oxidative treatment of wastewaters by aiding the novel self-ignition of the lamp on irradiation at low microwave power levels. This approach to self-ignition can potentially lead to considerable energy savings in such treatments. System performance was examined for the ignition power of microwaves of such MDEL devices in water, whose usefulness was assessed by investigating the photolytic transformation of aqueous solutions of representatives of three classes of contaminants: chlorinated phenols, herbicides and endocrine disruptors, specifically 4-chlorophenol (4-CP), 2,4-dichlorophenoxyacetic acid (2,4-D) and 4,4'-isopropylidenediphenol (bisphenol-A; BPA), respectively, taken as model wastewaters in air-equilibrated, in oxygen-saturated and in TiO2-containing aqueous media. The results are discussed in terms of the dynamics of the photo-induced degradation processes.
[Study on the distribution of plasma parameters in electrodeless lamp using emission spectrometry].
Wang, Chang-Quan; Zhang, Gui-Xin; Wang, Xin-Xin; Shao, Ming-Song; Dong, Jin-Yang; Wang, Zan-Ji
2011-09-01
Electrodeless lamp in pear shape was ignited using inductively coupled discharge setup and Ar-Hg mixtures as working gas. The changes in electronic temperature and density with axial and radial positions at 5 s of igniting were studied by means of emission spectrometry. The changes in electronic temperature were obtained according to the Ar line intensity ratio of 425.9 nm/ 750.4 nm. And the variations in electronic density were analyzed using 750.4 nm line intensity. It was found that plasma electronic temperature and density is various at different axial or radial positions. The electronic temperatures first increase, then decrease, and then increase quickly, and finally decline. While the electronic density firstly increase quickly, the decrease, and then rise slowly and finally decline again with axial distance increasing. With radial distance increasing, electronic temperature increases to a stable area, then continues to rise, while electronic density decreases.
Lamp method and apparatus using multiple reflections
MacLennan, D.A.; Turner, B.; Kipling, K.
1999-05-11
A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible is disclosed. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture. 20 figs.
High output lamp with high brightness
Kirkpatrick, Douglas A.; Bass, Gary K.; Copsey, Jesse F.; Garber, Jr., William E.; Kwong, Vincent H.; Levin, Izrail; MacLennan, Donald A.; Roy, Robert J.; Steiner, Paul E.; Tsai, Peter; Turner, Brian P.
2002-01-01
An ultra bright, low wattage inductively coupled electrodeless aperture lamp is powered by a solid state RF source in the range of several tens to several hundreds of watts at various frequencies in the range of 400 to 900 MHz. Numerous novel lamp circuits and components are disclosed including a wedding ring shaped coil having one axial and one radial lead, a high accuracy capacitor stack, a high thermal conductivity aperture cup and various other aperture bulb configurations, a coaxial capacitor arrangement, and an integrated coil and capacitor assembly. Numerous novel RF circuits are also disclosed including a high power oscillator circuit with reduced complexity resonant pole configuration, parallel RF power FET transistors with soft gate switching, a continuously variable frequency tuning circuit, a six port directional coupler, an impedance switching RF source, and an RF source with controlled frequency-load characteristics. Numerous novel RF control methods are disclosed including controlled adjustment of the operating frequency to find a resonant frequency and reduce reflected RF power, controlled switching of an impedance switched lamp system, active power control and active gate bias control.
Ury, M.; Sowers, F.; Harper, C.; Love, W.
1998-11-24
A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet. 7 figs.
Ury, Michael; Sowers, Frank; Harper, Curt; Love, Wayne
1998-01-01
A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet.
High brightness microwave lamp
Kirkpatrick, Douglas A.; Dolan, James T.; MacLennan, Donald A.; Turner, Brian P.; Simpson, James E.
2003-09-09
An electrodeless microwave discharge lamp includes a source of microwave energy, a microwave cavity, a structure configured to transmit the microwave energy from the source to the microwave cavity, a bulb disposed within the microwave cavity, the bulb including a discharge forming fill which emits light when excited by the microwave energy, and a reflector disposed within the microwave cavity, wherein the reflector defines a reflective cavity which encompasses the bulb within its volume and has an inside surface area which is sufficiently less than an inside surface area of the microwave cavity. A portion of the reflector may define a light emitting aperture which extends from a position closely spaced to the bulb to a light transmissive end of the microwave cavity. Preferably, at least a portion of the reflector is spaced from a wall of the microwave cavity. The lamp may be substantially sealed from environmental contamination. The cavity may include a dielectric material is a sufficient amount to require a reduction in the size of the cavity to support the desired resonant mode.
Fu, Jie; Wen, Teng; Wang, Qing; Zhang, Xue-Wei; Zeng, Qing-Fu; An, Shu-Qing; Zhu, Hai-Liang
2010-06-01
Degradation of Active Brilliant Red X-3B (X-3B) in aqueous solution by a microwave discharge electrodeless lamp (MDEL) in the presence of activated carbon was investigated. The preliminary results proved this method could effectively degrade X-3B in aqueous solution. The removal percentages of colour and chemical oxygen demand were up to approximately 99% and 66%, respectively, at the conditions of 0.8 g/L dye concentration, 20 g/L activated carbon, pH 7.0 and 8 min microwave irradiation time. The degradation basically belonged to first-order reaction kinetics and its rate constant was 0.42 min(-1). No aromatic organics were detected in the final treated solution, indicating that the mineralization was relatively complete. By studying the change in solution properties, it could be concluded that MDEL-assisted oxidation was the dominant reaction mechanism. In addition, the influence of operational parameters and reuse of activated carbon were also discussed.
Wedding ring shaped excitation coil
MacLennan, Donald A.; Tsai, Peter
2001-01-01
A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency.
Wang, Aimin; Zhang, Yanyu; Zhong, Huihui; Chen, Yu; Tian, Xiujun; Li, Desheng; Li, Jiuyi
2018-01-15
In this study, a novel photoelectro-Fenton (PEF) process using microwave discharge electrodeless lamp (MDEL) as a UV irradiation source was developed for the removal of antibiotic ciprofloxacin (CIP) in water. Comparative degradation of 200mgL -1 CIP was studied by direct MDEL photolysis, anodic oxidation (AO), AO in presence of electrogenerated H 2 O 2 (AO-H 2 O 2 ), AO-H 2 O 2 under MDEL irradiation (MDEL-AO-H 2 O 2 ), electro-Fenton (EF) and MDEL-PEF processes. Higher oxidation power was found in the sequence: MDEL photolysis < AO < AO-H 2 O 2 < MDEL-AO-H 2 O 2 < EF < MDEL-PEF. Effects of current density, pH, initial Fe 2+ concentration and initial CIP concentration on TOC removal in MDEL-PEF process were examined, and the optimal conditions were ascertained. The releases of three inorganic ions (F - , NH 4 + and NO 3 - ) and two carboxylic acids (oxalic and formic acids) were qualified. Seven aromatic intermediates mainly generated from hydroxylation, dealkylation and defluorination of CIP were detected by UPLC-QTOF-MS/MS technology. Therefore, plausible degradation sequences for CIP degradation in MDEL-PEF process including all detected products were proposed. Copyright © 2017 Elsevier B.V. All rights reserved.
High frequency inductive lamp and power oscillator
MacLennan, Donald A.; Dymond, Jr., Lauren E.; Gitsevich, Aleksandr; Grimm, William G.; Kipling, Kent; Kirkpatrick, Douglas A.; Ola, Samuel A.; Simpson, James E.; Trimble, William C.; Tsai, Peter; Turner, Brian P.
2001-01-01
A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and I or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to adjust the driving frequency of the oscillator.
1991-11-27
the methylene chloride/methanol mix. All test train components will be composited and explosives will be analyzed and reported on a total test train...check ute volume metering system nicked. dented. or cored . they Shall be note the barometric preure. nd the ulibration values ax the field test site...antimony, arsenic, cadmium, lead, selenium, thallium hollow cathode lamps (HCLs) or electrodeless discharge lamps (EDLs). [Same as EPA SW-846 Methods 7041
Microwave lamp with multi-purpose rotary motor
Ury, Michael G.; Turner, Brian; Wooten, Robert D.
1999-01-01
In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.
High frequency inductive lamp and power oscillator
MacLennan, Donald A.; Turner, Brian P.; Dolan, James T.; Kirkpatrick, Douglas A.; Leng, Yongzhang
2000-01-01
A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to match the driving frequency of the oscillator to a plurality of tuning states of the lamp.
Microwave lamp with multi-purpose rotary motor
Ury, M.G.; Turner, B.; Wooten, R.D.
1999-02-02
In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.
Increased collection efficiency of LIFI high intensity electrodeless light source
NASA Astrophysics Data System (ADS)
Hafidi, Abdeslam; DeVincentis, Marc; Duelli, Markus; Gilliard, Richard
2008-02-01
Recently, RF driven electrodeless high intensity light sources have been implemented successfully in the projection display systems for HDTV and videowall applications. This paper presents advances made in the RF waveguide and electric field concentrator structures with the purpose of reducing effective arc size and increasing light collection. In addition, new optical designs are described that further improve system efficiency. The results of this work demonstrate that projection system light throughput is increased relative to previous implementations and performance is optimized for home theater and other front projector applications that maintain multi-year lifetime without re-lamping, complete spectral range, fast start times and high levels of dynamic contrast due to dimming flexibility in the light source system.
Xu, Jianhui; Li, Chaolin; Liu, Peng; He, Di; Wang, Jianfeng; Zhang, Qian
2014-08-01
The photolysis of low concentration of H2S malodorous gas was studied under UV irradiation emitted by self-made high frequency discharge electrodeless lamp with atomic mercury lines at 185/253.7nm. Experiments results showed that the removal efficiency (ηH2S) of H2S was decreased with increasing initial H2S concentration and increased slightly with gas residence time. ηH2S was increased dramatically with relative humidity from<5% to 43% while the concentration of oxygen in gas environments affected the removal of H2S. The mechanisms for direct and indirect photolysis (generation of ozone) were illustrated by the experimental results on photolysis of H2S under argon environments and ozonation of H2S under air environments, respectively. The overall ηH2S by photolysis is higher than the combination of ηH2S by direct photolysis and ozonation, suggesting that hydroxyl radical-mediated indirect photolysis played an important role during photolysis processes. The main photolysis product was confirmed to be SO4(2-) with ion chromatograph. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skubin, V.K.; Sazonov, A.P.; Torgonenko, V.A.
1988-11-10
In this paper, using the example of unsaturated oligomeric esters, the effect of UV radiation of various domestic sources on the rate of curing of coatings is investigated. For the investigations a 60% styrene solution of PN-15 grade unsaturated oligomeric ester based on an equimolar ratio of maleic anhydride and oxypropylated diphenylenepropene was used. Isobutyl ether of benzoin served as the photoinitiator. The following lamps were used as radiation sources: electrodeless high-frequency lamps of continuous action with additions of mercury, cadmium, and phosphorus; a DRKS-500 mercury-xenon-arc lamp; and a DRT-1000 tubular mercury-arc lamp. When choosing UV sources to increase themore » efficiency of photochemical decay of the initiator and the rate of curing of the coating it is necessary first of all to be guided by the distribution of the spectral energy of the lamp radiation and the UV absorption spectrum of the photoinitiator.« less
Horikoshi, Satoshi; Miura, Takashi; Kajitani, Masatsugu; Serpone, Nick
2008-03-01
Exposure to low doses of the xenoestrogen bisphenol A (BPA) and to the hormonal 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide, an environmental endocrine disruptor, can have serious health consequences such as the induction of mammary gland ductal hyperplasias and carcinoma (LaChapelle et al., Reprod. Toxicol., 2007, 23, 20; Murray et al., Reprod. Toxicol., 2007, 23, 383). To the extent that these toxins are present in wastewaters (Donald et al., Sci. Total Environ. 1999, 231, 173; Brotons et al., Environ. Health Perspect. 1994, 103, 608; Olea et al., Environ. Health Perspect. 1996, 104, 298; Biles et al., J. Agric. Food Chem. 1997, 45, 3541; Markey et al., J. Steroid Biochem. Mol. Biol., 2003, 83, 235), we examined their oxidative destruction in aqueous media by a novel light source. A tungsten-triggered microwave discharge electrodeless lamp (W-MDEL) was fabricated for possible use in wastewater treatment using vacuum UV-transparent quartz in which a tungsten trigger, also embedded in quartz, was attached to the MDEL to aid in the self-ignition of the lamp on irradiation at low microwave power levels. The quantity of mercury gas in the W-MDEL was optimized by monitoring the continuous radiation and peak intensities of the emitted light in the vacuum UV (VUV) and UVC regions. The usefulness of the W-MDEL device was assessed through the degradation of 2,4-D and BPA in air-equilibrated aqueous media and in oxygen-saturated aqueous media. Enhanced degradation of these two xenoestrogenic toxins was achieved by increasing the number of W-MDEL devices while keeping constant the microwave radiation feeding each W-MDEL lamp. This novel lamp provides an additional light source in the photooxidation of environmental contaminants without the need for a metal-oxide photocatalyst. Under our conditions, process dynamics using the W-MDEL light source are greater than with the more conventional photochemical methods that employ low-pressure Hg arc electrode lamps in synthetic quartz to degrade these two toxic contaminants.
Cheng, Gong; Lin, Jing; Lu, Jian; Zhao, Xi; Cai, Zhengqing; Fu, Jie
2015-01-01
The photo-Fenton reaction is a promising method to treat organic contaminants in water. In this paper, a Fenton reagent enhanced by microwave electrodeless ultraviolet (MWEUV/Fenton) method was proposed for advanced treatment of nonbiodegradable organic substance in pesticide-containing biotreated wastewater. MWEUV lamp was found to be more effective for chemical oxygen demand (COD) removal than commercial mercury lamps in the Fenton process. The pseudo-first order kinetic model can well describe COD removal from pesticide-containing wastewater by MWEUV/Fenton, and the apparent rate constant (k) was 0.0125 min−1. The optimal conditions for MWEUV/Fenton process were determined as initial pH of 5, Fe2+ dosage of 0.8 mmol/L, and H2O2 dosage of 100 mmol/L. Under the optimal conditions, the reaction exhibited high mineralization degrees of organics, where COD and dissolved organic carbon (DOC) concentration decreased from 183.2 mg/L to 36.9 mg/L and 43.5 mg/L to 27.8 mg/L, respectively. Three main pesticides in the wastewater, as Dimethoate, Triazophos, and Malathion, were completely removed by the MWEUV/Fenton process within 120 min. The high degree of pesticides decomposition and mineralization was proved by the detected inorganic anions. PMID:26347877
Lamp method and apparatus using multiple reflections
MacLennan, Donald A.; Turner, Brian P.
2001-01-01
An electrodeless microwave discharge lamp includes an envelope with a discharge forming fill disposed therein which emits light, the fill being capable of absorbing light at one wavelength and re-emitting the absorbed light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill, a source of microwave energy coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed within the microwave cavity and configured to reflect at least some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length.
Lee, Do-Jin; Kim, Hangun; Park, Young-Kwon; Kim, Byung Hoon; Lee, Heon; Jungf, Sana-Chul
2016-02-01
In this study, an MDEL/TiO2 photocatalyst hybrid system was applied to the production of low molecular weight gelatin. The molecular weight of produed gelatin decreased with increasing microwave intensity and increasing treatment time. The abscission of the chemical bonds between the con- stituents of gelatin by photocatalytic reaction did not alter the characteristics of gelatin. Formation of any by-products due to side reaction was not observed. It is suggested that gelatin was depolymerized by hydroxyl radicals produced during the MDEL/TiO2 photochemical reaction.
Lee, Do-Jin; Kim, Byung Hoon; Kim, Sun-Jae; Kim, Jung-Sik; Lee, Heon; Jung, Sang-Chul
2015-01-01
An MDEL/TiO2 photo-catalyst hybrid system was applied, for the first time, for the production of low molecular weight heparin. The molecular weight of produed heparin decreased with increasing microwave intensity and treatment time. The abscission of the chemical bonds between the constituents of heparin by photo-catalytic reaction did not alter the characteristics of heparin. Formation of by-products due to side reaction was not observed. It is suggested that heparin was depolymerized by active oxygen radicals produced during the MDEL/TiO2 photo-chemical reaction.
Electrodeless plasma thrusters for spacecraft: A review
NASA Astrophysics Data System (ADS)
Bathgate, S. N.; Bilek, M. M. M.; McKenzie, D. R.
2017-08-01
The physics of electrodeless electric thrusters that use directed plasma to propel spacecraft without employing electrodes subject to plasma erosion is reviewed. Electrodeless plasma thrusters are potentially more durable than presently deployed thrusters that use electrodes such as gridded ion, Hall thrusters, arcjets and resistojets. Like other plasma thrusters, electrodeless thrusters have the advantage of reduced fuel mass compared to chemical thrusters that produce the same thrust. The status of electrodeless plasma thrusters that could be used in communications satellites and in spacecraft for interplanetary missions is examined. Electrodeless thrusters under development or planned for deployment include devices that use a rotating magnetic field; devices that use a rotating electric field; pulsed inductive devices that exploit the Lorentz force on an induced current loop in a plasma; devices that use radiofrequency fields to heat plasmas and have magnetic nozzles to accelerate the hot plasma and other devices that exploit the Lorentz force. Using metrics of specific impulse and thrust efficiency, we find that the most promising designs are those that use Lorentz forces directly to expel plasma and those that use magnetic nozzles to accelerate plasma.
Light Sources and Ballast Circuits
NASA Astrophysics Data System (ADS)
Yorifuji, Takashi; Sakai, Makoto; Yasuda, Takeo; Maehara, Akiyoshi; Okada, Atsunori; Gouriki, Takeshi; Mannami, Tomoaki
According to the machinery statistics by Ministry of Economy, Trade and Industry (METI), the total of domestic light bulb production in 2006 was 1,101 million (88.5% year-on-year). Production for general purpose illumination light bulbs and halogen light bulbs accounted for 122 million (99.2% y/y) and 45 million (96.3% y/y), respectively. The total of fluorescent lamp production was 988 million (114.9%) and the production of general purpose fluorescent lamps excluding backlights accounted for 367 million (101.7% y/y). Further, HID lamp production was 10 million (106.3% y/y). What is noteworthy regarding such lamp production is that, similar to the previous year, the sales volume (amount) of lamps for general illumination exceeded 100% against the previous year, indicating a steady shift to high value added products. Major lighting exhibitions in 2006 included the Light + Building Trade Fair held in Frankfurt in April and the Light Fair International 2006 held in Las Vegas, U.S.A. in May, both of which demonstrated signs of acceleration toward energy saving, high efficiency and resource saving. As for incandescent lamps, products filled with larger atomic weight gases aiming at higher efficiency/longer life are becoming the mainstream. As for new technologies, it was experimentally demonstrated that infrared radiation can be suppressed by processing micro cavities to metal plates made of tungsten, tantalum, etc. For fluorescent lamps, straight and circular fluorescent lamps achieving a longer life/higher luminous flux maintenance factor continued to be widely developed/launched again this year. For compact fluorescent lamps, energy saving/high efficiency products, multifunctional type products combined with LED and new shaped products were launched. As to HID lamps, ceramic metal halide lamps with high efficiency, improved color rendering, longer life and higher luminous flux maintenance factor were commercialized one after another. Numerous studies and analyses, on discharge models were reported. Further, studies on ultra high-pressure mercury lamps as light sources for projectors are becoming the mainstream of HID lamp related researches. For high-pressure sodium lamps, many studies on plant growing and pest control utilizing low insect attracting aspects were also reported in 2006. Additionally, for discharge lamps, the minimum sustaining electric power for arc tubes employed in electrode-less compact fluorescent lamps was investigated. For Hg-free rare-gas fluorescent lamps, a luminance of 10,000cd/m2 was attained by a 1 meter-long external duplex spiral electrode prototype using Xe/Ne barrier discharge. As to startup circuits, the commercialization of energy saving and high value added products mainly associated with fluorescent lamps and HID lamps are becoming common. Further, the miniaturization of startup circuits for self electronic-ballasted lamps has advanced. Speaking of the overall light sources and startup circuits in 2006 and with the enforcement of RoHS in Europe in July, the momentum toward hazardous substance-free and energy saving initiatives has been enhanced from the perspective of protecting the global environment. It is anticipated that similar restrictions will be globally enforced in the future.
NASA Astrophysics Data System (ADS)
Statnic, Eugen; Tanach, Valentin
2006-08-01
The inductively coupled fluorescent lamp with a cored induction coil placed in a re-entrant cavity is in fact a coaxial transformer operated in the radiofrequency range between 100 kHz and a few MHz. The magnetic coupling coefficient k between the primary coil and the plasma ring is relatively low because of the open magnetic circuit. The acting mutual inductance M enables us to quantify the interaction between the magnetic field produced by the primary coil current I1 and the opposing magnetic field produced by the powerful plasma current I2. A contra-electromotive force jωMI2 is induced in the induction coil L1, defining the primary voltage V1 = I1(R1 + jω L1) - jωMI2. The current I1 induces in the secondary conductive plasma the driving electromotive force jωMI1 supplying the secondary load consisting of the average plasma resistance R2 and the secondary inductance L2, according to the equation jωMI2 = I2(R2 + jωL2). It is the aim of this paper to find a model to determine k on the basis of the measured primary parameters V1, I1, P1, L1, R1 and finally all electrical inaccessible parameters, such as M, V2, I2, phiv2, L2, R2, in order to optimize the discharge and lamp efficacy. The complex characteristic of plasma inductance for this type of lamp is analysed and clarified. Some reflexive basic relations verifying the correctness of the inferred plasma parameters are also developed. The described experiments are related to a lamp working at about 2.6 MHz.
Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources
NASA Technical Reports Server (NTRS)
McAndrew, Brendan; Cooper, John; Arecchi, Angelo; McKee, Greg; Durell, Christopher
2012-01-01
Stable high radiance in visible and near-ultraviolet wavelengths is desirable for radiometric calibration sources. In this work, newly available electrodeless radio-frequency (RF) driven plasma light sources were combined with research grade, low-noise power supplies and coupled to an integrating sphere to produce a uniform radiance source. The stock light sources consist of a 28 VDC power supply, RF driver, and a resonant RF cavity. The RF cavity includes a small bulb with a fill gas that is ionized by the electric field and emits light. This assembly is known as the emitter. The RF driver supplies a source of RF energy to the emitter. In commercial form, embedded electronics within the RF driver perform a continual optimization routine to maximize energy transfer to the emitter. This optimization routine continually varies the light output sinusoidally by approximately 2% over a several-second period. Modifying to eliminate this optimization eliminates the sinusoidal variation but allows the output to slowly drift over time. This drift can be minimized by allowing sufficient warm-up time to achieve thermal equilibrium. It was also found that supplying the RF driver with a low-noise source of DC electrical power improves the stability of the lamp output. Finally, coupling the light into an integrating sphere reduces the effect of spatial fluctuations, and decreases noise at the output port of the sphere.
[The Performance Analysis for Lighting Sources in Highway Tunnel Based on Visual Function].
Yang, Yong; Han, Wen-yuan; Yan, Ming; Jiang, Hai-feng; Zhu, Li-wei
2015-10-01
Under the condition of mesopic vision, the spectral luminous efficiency function is shown as a series of curves. Its peak wavelength and intensity are affected by light spectrum, background brightness and other aspects. The impact of light source to lighting visibility could not be carried out via a single optical parametric characterization. The reaction time of visual cognition is regard as evaluating indexes in this experiment. Under the condition of different speed and luminous environment, testing visual cognition based on vision function method. The light sources include high pressure sodium, electrodeless fluorescent lamp and white LED with three kinds of color temperature (the range of color temperature is from 1 958 to 5 537 K). The background brightness value is used for basic section of highway tunnel illumination and general outdoor illumination, its range is between 1 and 5 cd x m(-)2. All values are in the scope of mesopic vision. Test results show that: under the same condition of speed and luminance, the reaction time of visual cognition that corresponding to high color temperature of light source is shorter than it corresponding to low color temperature; the reaction time corresponding to visual target in high speed is shorter than it in low speed. At the end moment, however, the visual angle of target in observer's visual field that corresponding to low speed was larger than it corresponding to high speed. Based on MOVE model, calculating the equivalent luminance of human mesopic vision, which is on condition of different emission spectrum and background brightness that formed by test lighting sources. Compared with photopic vision result, the standard deviation (CV) of time-reaction curve corresponding to equivalent brightness of mesopic vision is smaller. Under the condition of mesopic vision, the discrepancy between equivalent brightness of different lighting source and photopic vision, that is one of the main reasons for causing the discrepancy of visual recognition. The emission spectrum peak of GaN chip is approximate to the wave length peak of efficiency function in photopic vision. The lighting visual effect of write LED in high color temperature is better than it in low color temperature and electrodeless fluorescent lamp. The lighting visual effect of high pressure sodium is weak. Because of its peak value is around the Na+ characteristic spectra.
Horikoshi, Satoshi; Tsuchida, Akihiro; Shinomiya, Tomohiro; Serpone, Nick
2015-12-01
This article reports on the fabrication and enhanced performance of a novel microwave discharge electrodeless lamp (MDEL) consisting of a three layered cylindrical structure that was effective in the remediation of wastewater containing the 2,4-D herbicide and the near total sterilization of bacteria-contaminated pond water (E. coli and other microorganisms) through photolysis with the emitted vacuum-UV (185 nm) and UVC (254 nm) light from the MDEL and through chemical oxidation with reactive oxygen species (ROS) produced by the photolysis of dioxygen and air oxygen through one of the photoreactors. The flow rates of the 1.0 L contaminated waters were 0.6 and 1.2 L min(-1). The integrated UV/ROSO2 and UV/ROSair methods used to carry out the degradation of 2,4-D and sterilization processes were more effective than either the UV method alone or the ROSO2 and ROSair methods for short time periods (5 or 8 min). At a lower flow rate, 79% of 2,4-D was degraded by the UV/ROSO2 method and 55% by UV/ROSair after 8 min. At a faster flow rate of 1.2 L min(-1), degradation of 2,4-D in 1.0 L volume of water was 84% and 77% complete by the UV/ROSO2 and the UV/ROSair method, respectively, after 8 min of irradiation. The number of kills of E. coli bacteria was nearly quantitative (98 and 99%) by the UV/ROSO2 and UV/ROSair methods after treating the contaminated water for 5 min. The decrease of total viable microorganisms in pond water was 90% and 80% after 5 min of microwave irradiation at a flow rate of 1.2 L min(-1) by the integrated methods UV/ROSO2 and UV/ROSair, respectively. The rate of flow of oxygen gas through the photoreactor impacted the extent of degradation and the related dynamics of the 2,4-D herbicide.
Electrodeless QCM-D for lipid bilayer applications.
Kunze, Angelika; Zäch, Michael; Svedhem, Sofia; Kasemo, Bengt
2011-01-15
An electrodeless quartz crystal microbalance with dissipation monitoring (QCM-D) setup is used to monitor the formation of supported lipid bilayers (SLBs) on bare quartz crystal sensor surfaces. The kinetic behavior of the formation of a 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) SLB on SiO(2) surfaces is discussed and compared for three cases: (i) a standard SiO(2) film deposited onto the gold electrode of a quartz crystal, (ii) an electrodeless quartz crystal with a sputter-coated SiO(2) film, and (iii) an uncoated electrodeless quartz crystal sensor surface. We demonstrate, supported by imaging the SLB on an uncoated electrodeless surface using atomic force microscopy (AFM), that a defect-free, completely covering bilayer is formed in all three cases. Differences in the kinetics of the SLB formation on the different sensor surfaces are attributed to differences in surface roughness. The latter assumption is supported by imaging the different surfaces using AFM. We show furthermore that electrodeless quartz crystal sensors can be used not only for the formation of neutral SLBs but also for positively and negatively charged SLBs. Based on our results we propose electrodeless QCM-D to be a valuable technique for lipid bilayer and related applications providing several advantages compared to electrode-coated surfaces like optical transparency, longer lifetime, and reduced costs. Copyright © 2010 Elsevier B.V. All rights reserved.
Cao, Xia; Zhang, Meng; Huang, Jinrong; Jiang, Tao; Zou, Jingdian; Wang, Ning; Wang, Zhong Lin
2018-02-01
Wireless power delivery has been a dream technology for applications in medical science, security, radio frequency identification (RFID), and the internet of things, and is usually based on induction coils and/or antenna. Here, a new approach is demonstrated for wireless power delivery by using the Maxwell's displacement current generated by an electrodeless triboelectric nanogenerator (TENG) that directly harvests ambient mechanical energy. A rotary electrodeless TENG is fabricated using the contact and sliding mode with a segmented structure. Due to the leakage of electric field between the segments during relative rotation, the generated Maxwell's displacement current in free space is collected by metal collectors. At a gap distance of 3 cm, the output wireless current density and voltage can reach 7 µA cm -2 and 65 V, respectively. A larger rotary electrodeless TENG and flexible wearable electrodeless TENG are demonstrated to power light-emitting diodes (LEDs) through wireless energy delivery. This innovative discovery opens a new avenue for noncontact, wireless energy transmission for applications in portable and wearable electronics. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Oliveira, Jussiane S S; Picoloto, Rochele S; Bizzi, Cezar A; Mello, Paola A; Barin, Juliano S; Flores, Erico M M
2015-11-01
A method for the simultaneous determination of Ni, V and S in petroleum coke by inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted ultraviolet digestion (MW-UV) in closed vessels was proposed. Digestion was performed using electrodeless discharge lamps positioned inside quartz vessels and turned on by microwave radiation. The following parameters were evaluated: HNO3 concentration (15 mL of 1, 4, 7, 10 or 14.4 mol L(-1)), volume of H2O2 (30%, 1 or 3 mL), sample mass (100, 250 or 500 mg) and heating time (40 or 60 min) with or without the use of UV lamps. Digestion efficiency was evaluated by the determination of the residual carbon content (RCC) in digests. Using UV lamps lower RCC was obtained and the combination of 4 mol L(-1) HNO3 with 3 mL of H2O2 and 60 min of heating allowed a suitable digestion of up to 500 mg of petroleum coke (RCC< 21%). The agreement with the reference values for Ni, V and S (obtained by digestion of petroleum coke by microwave-induced combustion) and with a certified reference material of petroleum coke was between 96 and 101%. The proposed method was considered as advantageous when compared to American Society for Testing and Materials method because it allowed the simultaneous determination of Ni, V and S with lower limit of detection (0.22, 0.12 and 8.7 µg g(-1) for Ni, V and S, respectively) avoiding the use of concentrated nitric acid and providing digests suitable for routine analysis by ICP-OES. Copyright © 2015 Elsevier B.V. All rights reserved.
A Faraday laser lasing on Rb 1529 nm transition.
Chang, Pengyuan; Peng, Huanfa; Zhang, Shengnan; Chen, Zhangyuan; Luo, Bin; Chen, Jingbiao; Guo, Hong
2017-08-21
We present the design and performance characterization of a Faraday laser directly lasing on the Rb 1529 nm transition (Rb, 5P 3/2 - 4D 5/2 ) with high stability, narrow spectral linewidth and low cost. This system does not need an additional frequency-stabilized pump laser as a prerequisite to preparing Rb atom from 5S to 5P excited state. Just by using a performance-improved electrodeless discharge lamp-based excited-state Faraday anomalous dispersion optical filter (LESFADOF), we realized a heterogeneously Faraday laser with the frequency corresponding to atomic transition, working stably over a range of laser diode (LD) current from 85 mA to 171 mA and the LD temperature from 11 °C to 32 °C, as well as the 24-hour long-term frequency fluctuation range of no more than 600 MHz. Both the laser linewidth and relative intensity noisy (RIN) are measured. The Faraday laser lasing on Rb 1529 nm transition (telecom C-band) can be applied to further research on metrology, microwave photonics and optical communication systems. Besides, since the transitions correspongding to the populated excited-states of alkali atoms within lamp are extraordinarily rich, this scheme can increase the flexibility for choosing proper wavelengths for Faraday laser and greatly expand the coverage of wavelength corresponding to atomic transmission for laser frequency stabilization.
NASA Astrophysics Data System (ADS)
Zissis, Georges; Haverlag, Marco
2010-06-01
Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric light sources consume almost 19% of worldwide electricity production. Finding new ways to light lamps is a challenge where the stakes are scientific, technological, economic and environmental. The production of more efficient light sources is a sustainable solution for humanity. There are many opportunities for not only enhancing the efficiency and reliability of lighting systems but also for improving the quality of light as seen by the end user. This is possible through intelligent use of new technologies, deep scientific understanding of the operating principles of light sources and knowledge of the varied human requirements for different types of lighting in different settings. A revolution in the domain of light source technology is on the way: high brightness light emitting diodes arriving in the general lighting market, together with organic LEDs (OLEDs), are producing spectacular advances. However, unlike incandescence, electrical discharge lamps are far from disappearing from the market. In addition, new generations of discharge lamps based on molecular radiators are becoming a reality. There are still many scientific and technological challenges to be raised in this direction. Diagnostics are important for understanding the fundamental mechanisms taking place in the discharge plasma. This understanding is an absolute necessity for system optimization leading to more efficient and high quality light sources. The studied medium is rather complex, but new diagnostic techniques coupled to innovative ideas and powerful tools have been developed in recent years. This cluster issue of seven papers illustrates these efforts. The selected papers cover all domains, from high to low pressure and dielectric barrier lamps, from breakdown to acoustic resonance. Especially in the domain of high pressure lamps, J J Curry shows how coherent and incoherent x-ray scattering can be used as an imaging technique adapted to lamps. J Hirsch et al treat the acoustic resonance phenomenon that seriously limits the frequency domain for high pressure lamp operation. M Jinno et al illustrate a method that allows for measuring Xe buffer gas pressure in Hg-free metal halide lamps for automotive applications. In the domain of low pressure lamps, M Gendre et al investigate the breakdown phase by means of optical and electrical diagnostic tools. The similarity rules used a long time ago for simulating plasma behaviour based on invariants are now serving as diagnostic tools, as shown in the paper by D Michael et al. N Dagang et al show how impurities can be detected in Hg-free electrodeless lamps and more particularly in dielectric barrier discharges emitting excimer radiation. The quality of light is illustrated by a final example by R Kozakov et al on how to qualify the light output from the lamp with respect to biological effects on humans.
Improvements in the EQ-10 electrodeless Z-pinch EUV source for metrology applications
NASA Astrophysics Data System (ADS)
Horne, Stephen F.; Gustafson, Deborah; Partlow, Matthew J.; Besen, Matthew M.; Smith, Donald K.; Blackborow, Paul A.
2011-04-01
Now that EUV lithography systems are beginning to ship into the fabs for next generation chips it is more critical that the EUV infrastructure developments are keeping pace. Energetiq Technology has been shipping the EQ-10 Electrodeless Z-pinch™ light source since 2005. The source is currently being used for metrology, mask inspection, and resist development. These applications require especially stable performance in both power and source size. Over the last 5 years Energetiq has made many source modifications which have included better thermal management as well as high pulse rate operation6. Recently we have further increased the system power handling and electrical pulse reproducibility. The impact of these modifications on source performance will be reported.
Electrodeless Plasma Source: Phase II Update
NASA Astrophysics Data System (ADS)
Prager, James; Ziemba, Timothy; Miller, Kenneth
2012-10-01
Eagle Harbor Technologies, in collaboration with the University of Washington, has developed a low-impurity, electrode-less plasma source (EPS) for start-up and source plasma injection for fusion science applications. In order to not interfere with the experiment, a pre-ionizer/plasma source must meet a few critical criteria including low impurity production, low electromagnetic interference (EMI), and minimal disruption to the magnetic geometry of the experiment. This system was designed to be UHV compatible and bakable. Here we present the results of the EPS Phase II upgrade. The output plasma density was increased by two orders of magnitude to >10^17 m-3 in hydrogen with no magnetic field injected. EPS system integration with the HIT-SI experiment has begun.
Coupled microwave/photoassisted methods for environmental remediation.
Horikoshi, Satoshi; Serpone, Nick
2014-11-05
The microwave-induced acceleration of photocatalytic reactions was discovered serendipitously in the late 1990s. The activity of photocatalysts is enhanced significantly by both microwave radiation and UV light. Particularly relevant, other than as a heat source, was the enigmatic phenomenon of the non-thermal effect(s) of the microwave radiation that facilitated photocatalyzed reactions, as evidenced when examining various model contaminants in aqueous media. Results led to an examination of the possible mechanism(s) of the microwave effect(s). In the present article we contend that the microwaves' non-thermal effect(s) is an important factor in the enhancement of TiO2-photoassisted reactions involving the decomposition of organic pollutants in model wastewaters by an integrated (coupled) microwave-/UV-illumination method (UV/MW). Moreover, such coupling of no less than two irradiation methods led to the fabrication and ultimate investigation of microwave discharged electrodeless lamps (MDELs) as optimal light sources; their use is also described. The review focuses on the enhanced activity of photocatalytic reactions when subjected to microwave radiation and concentrates on the authors' research of the past few years.
Hyperfine structure measurements of neutral iodine atom (127I) using Fourier Transform Spectrometry
NASA Astrophysics Data System (ADS)
Ashok, Chilukoti; Vishwakarma, S. R.; Bhatt, Himal; Ankush, B. K.; Deo, M. N.
2018-01-01
We report the hyperfine Structure (hfs) splitting observations of neutral iodine atom (II) in the 6000 - 10,000 cm-1 near infrared spectral region. The measurements were carried out using a high-resolution Fourier Transform Spectrometer (FTS), where an electrodeless discharge lamp (EDL), excited using microwaves, was employed as the light source and InGaAs as the light detector. A specially designed setup was used to lower the plasma temperature of the medium so as to reduce the Doppler width and consequently to increase the spectral resolution of hfs components. A total of 183 lines with hfs splitting have been observed, out of which hfs in 53 spectral lines are reported for the first time. On the basis of hfs analysis, we derived the magnetic dipole and electric quadrupole coupling constants, A and B respectively for 30 even and 30 odd energy levels and are compared with the values available in the literature. New hfs values for 5 even and 4 odd levels are also reported here for the first time.
NASA Astrophysics Data System (ADS)
Courret, Gilles; Nikkola, Petri; Wasterlain, Sébastien; Gudozhnik, Olexandr; Girardin, Michel; Braun, Jonathan; Gavin, Serge; Croci, Mirko; Egolf, Peter W.
2017-08-01
In an applied research project on the development of a pulsed microwave sulfur lamp prototype of 1 kW, we have discovered an amazing phenomenon in which the plasma forms a ball staying at the center of the bulb despite gravity, thus protecting the glass from melting. In this paper, it is shown that this results from an acoustic resonance in a spherical mode. Measurements of the plasma response to short pulses are presented showing beats at the spherical resonance. It is demonstrated that the beats could result from the simultaneous excitation of two normal modes with a frequency difference of approximately 1%. One of the two frequencies matches precisely the microwave pulses repetition, a little below 30 kHz. Thus this one is due to a forced oscillation, whereas the other one is due to a free oscillation. The phase velocity of sound was calculated as a function of temperature in order to find the series of temperatures at which a resonance would occur if the bulb were an isothermal solid sphere. The mean temperature inside the actual bulb was determined from the only doublet of this series, that has characteristic frequencies close enough to cause the observed beats. In addition, one of these two modes has a spherical symmetry that can explain the plasma ball formation. The obtained mean temperature is consistent with the direct measurements on the bulb surface as well as with the temperature in the core of a similar plasma found in the literature. We have also proposed a model of the resonance onset based on the acoustic dispersion and the sound amplification due to electromagnetic coupling.
High brightness electrodeless Z-Pinch EUV source for mask inspection tools
NASA Astrophysics Data System (ADS)
Horne, Stephen F.; Partlow, Matthew J.; Gustafson, Deborah S.; Besen, Matthew M.; Smith, Donald K.; Blackborow, Paul A.
2012-03-01
Energetiq Technology has been shipping the EQ-10 Electrodeless Z-pinchTM light source since 1995. The source is currently being used for metrology, mask inspection, and resist development. Energetiq's higher brightness source has been selected as the source for pre-production actinic mask inspection tools. This improved source enables the mask inspection tool suppliers to build prototype tools with capabilities of defect detection and review down to 16nm design rules. In this presentation we will present new source technology being developed at Energetiq to address the critical source brightness issue. The new technology will be shown to be capable of delivering brightness levels sufficient to meet the HVM requirements of AIMS and ABI and potentially API tools. The basis of the source technology is to use the stable pinch of the electrodeless light source and have a brightness of up to 100W/mm(carat)2-sr. We will explain the source design concepts, discuss the expected performance and present the modeling results for the new design.
NASA Astrophysics Data System (ADS)
Haverlag, Marco; Kroesen, Gerrit; Ferguson, Ian
2011-06-01
The papers in this special issue of Journal of Physics D: Applied Physics (JPhysD) originate from the 12th International Symposium on the Science and Technology of Light Sources and the 3rd International Conference on White LEDs and Solid State Lighting, held 11-16 July 2010 at Eindhoven University. Abstracts of all papers presented at this combined conference were published in the Conference Proceedings LS-WLED 2010 by FAST-LS, edited by M Haverlag, G M W Kroesen and T Taguchi. Special issues of the previous three LS conferences have been well-cited and have proven to be an important source of information for the lighting community. The 2010 LS-Symposium was a combined conference with the White LED Conference in order to enhance the scope of this conference series towards new light source technologies such as LEDs and OLEDs, and this co-operation will be continued in the future. Given the faster technology development in these areas it was also decided to shorten the interval between conferences from three to two years. Well over 200 invited presentations, landmark presentations and poster contributions were presented at the 2010 LS-Symposium. The organizing committee have selected from these a number of outstanding contributions with a high technological content and invited the authors to submit a full paper in JPhysD. The criteria were that the work should not be a repetition of the work already published in the Proceedings, but should be new, complete, within the scope of JPhysD, and meeting the normal quality standards of this journal. After peer review a combined set of 18 papers is published in this JPhysD special issue. In addition, a number of lighting-application-orientated papers will be published in a special issue of Journal of Light & Visual Environment later in 2011. The papers in this special issue of JPhysD show that research in the science and technology of light sources still covers a broad set of subject areas which includes both 'classical' discharge light sources and (O)LED sources, and new concepts are still being added to the range of technologies that are being used in practice. A truly classic aspect of lamp operation is lumen maintenance, and despite being in use for almost 50 years, Na/Sc quartz metal halide lamps until recently still suffered from a strong lumen depreciation over life. This issue has been resolved to a large extent with the introduction of high-frequency operation. In the paper of Van Erk et al, indications are given as to why this mode of operation is so successful. Another classic theme in the area of discharge lamp sources is ignition, still a major issue. In two consecutive papers by Sobota et al, several aspects of the cold ignition of ceramic metal halide lamps are discussed, including statistical delay effects, the role of the driving voltage, and ignition aids. The ignition becomes more complex when mercury is left out of a metal halide lamp and this is clearly shown in the paper by Estupiñán et al. When not buffered by mercury, water impurities will give rise to the formation of hydrogen iodide, which is very volatile and a strongly electronegative species, thereby hampering the ignition process. Mercury-free metal halide lamps will potentially show very different spectral properties. This is shown in the paper by Käning et al, where use has been made of the ongoing improvements in ceramic lamp technology to make lamps with a high rare-earth iodide content. It was found that in such lamps the contribution of molecular lines can become so important that some lines even become self-reversed. This opens new possibilities for making high-quality white light sources without mercury while retaining the use of electrodes. High rare-earth content also changes the behaviour of electrodes as a result of the lowering of the work function due to gas-phase emitter effects. In the paper by Reinelt et al some clear examples of this effect are investigated as well as their dependence on the operational frequency in ceramic metal halide lamps. Despite the fact that ceramic metal halide lamps with electrodes have already been on the market for more than 15 years, the latest developments in materials and lamp-shaping technologies continue to push the limits of efficiency and colour quality of these lamps. In an effort to clarify the energy balance of these lamps, Rijke et al have shown that it is possible to deduce from integrated sphere measurements in the visible and IR region the complete energy balance of such lamps. This method will provide valuable insights to push the efficacy of HID technologies even further. New concepts based on discharges are also being proposed and some of these are also being introduced to the market. It is interesting to note that all of these concepts are either mercury-free or can easily be adapted to mercury-free versions. One such contender is the electrodeless HID lamp. In the paper by Gilliard et al it is shown how a cavity resonator can be effectively used to couple power into a capacitively coupled electrodeless metal halide lamp. In contrast, the paper by Hilbig et al shows a concept in which the power is inductively coupled. Both methods potentially offer more freedom in salt choice, and this is used in the paper by Hilbig et al to test various new molecular radiators including some oxygen-containing molecules. With a larger choice of applicable salt systems, it becomes even more important to know the thermodynamical properties of rare-earth molecules. A nice overview of these properties for the mono-halides is given in the paper by Mucklejohn. Operating at lower pressures is another concept; employment of phosphor-converted DBD and microplasma lamps is studied in the papers by Eden et al and Guivan et al. A relatively new concept based on pulsed operation of pure Xe discharges and phosphor conversion is described by Motomura et al. These papers show that there is still an abundance of developments in discharge-based light sources. However, the progress in the last few years in LED and OLED sources has been even greater. In the editorial for the LS-11 conference by previous guest editor David Wharmby, it was stated that most LED lighting was still mostly used for signalling and decorative sources. In the three years that have passed, things have changed considerably and we now see LED light sources entering every application, ranging from street lighting and parking lots to shop lighting and even greenhouses. Currently LED prices for traditional lighting applications are high, but they are dropping rapidly. The papers published in this special issue give some indications of things to come. The paper by Jamil et al deals with the possibility of using silicon wafers as substrate material instead of the now commonly used (but more expensive) sapphire substrates. This is attractive from a cost price point of view, but leads to an increased lattice mismatch and therefore strain-induced defects. In this paper it is shown that when using intermediate matching layers it is possible to retain the same electrical and optical properties as with structures on sapphire. Another aspect that directly relates to cost is efficiency and droop in green InGaN devices, which is addressed in the paper by Lee et al. They show that by providing a flow of trymethylindium prior to the growth of the quantum wells it is possible to significantly increase the internal quantum efficiency of green LEDs. Improvement of the optical out-coupling of InGaN LEDs is discussed by Mak et al, and it is found that localized plasmon resonance of metallic nanoparticles (and especially silver) can help to increase the optical out-coupling in the wavelength region of interest. Nanoparticles in the form of ZnO nanorods are described by Willander et al as a possibility for phosphor-free wavelength conversion on polymer (O)LEDs. More advanced functions besides light emission can be achieved with OLEDs and this is demonstrated in the article by Generali et al which describes various aspects of organic light-emitting (field) transistors based on different substrates. The guest editors of this special issue of Journal of Physics D: Applied Physics would like to thank all the colleagues who helped us identify this exhaustive collection of papers. There are too many people to list here, but we know them well and are grateful for their help.
EQ-10 electrodeless Z-pinch EUV source for metrology applications
NASA Astrophysics Data System (ADS)
Gustafson, Deborah; Horne, Stephen F.; Partlow, Matthew J.; Besen, Matthew M.; Smith, Donald K.; Blackborow, Paul A.
2011-11-01
With EUV Lithography systems shipping, the requirements for highly reliable EUV sources for mask inspection and resist outgassing are becoming better defined, and more urgent. The sources needed for metrology applications are very different than that needed for lithography; brightness (not power) is the key requirement. Suppliers for HVM EUV sources have all resources working on high power and have not entered the smaller market for metrology. Energetiq Technology has been shipping the EQ-10 Electrodeless Z-pinchTM light source since 19951. The source is currently being used for metrology, mask inspection, and resist development2-4. These applications require especially stable performance in both output power and plasma size and position. Over the last 6 years Energetiq has made many source modifications which have included better thermal management to increase the brightness and power of the source. We now have introduced a new source that will meet requirements of some of the mask metrology first generation tools; this source will be reviewed.
Electrodeless plasma acceleration system using rotating magnetic field method
NASA Astrophysics Data System (ADS)
Furukawa, T.; Takizawa, K.; Kuwahara, D.; Shinohara, S.
2017-11-01
We have proposed Rotating Magnetic Field (RMF) acceleration method as one of electrodeless plasma accelerations. In our experimental scheme, plasma generated by an rf (radio frequency) antenna, is accelerated by RMF antennas, which consist of two-pair, opposed, facing coils, and these antennas are outside of a discharge tube. Therefore, there is no wear of electrodes, degrading the propulsion performance. Here, we will introduce our RMF acceleration system developed, including the experimental device, e.g., external antennas, a tapered quartz tube, a vacuum chamber, external magnets, and a pumping system. In addition, we can change RMF operation parameters (RMF applied current IRMF and RMF current phase difference ϕ, focusing on RMF current frequency fRMF) by adjusting matching conditions of RMF, and investigate the dependencies on plasma parameters (electron density ne and ion velocity vi); e.g., higher increases of ne and vi (˜360 % and 55 %, respectively) than previous experimental results were obtained by decreasing fRMF from 5 MHz to 0.7 MHz, whose RMF penetration condition was better according to Milroy's expression. Moreover, time-varying component of RMF has been measured directly to survey the penetration condition experimentally.
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2013 CFR
2013-01-01
... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2014 CFR
2014-01-01
... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2012 CFR
2012-01-01
... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...
Rf capacitively-coupled electrodeless light source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manos, Dennis M.; Diggs, Jessie; Ametepe, Joseph D.
2000-01-01
An rf capacitively-coupled electrodeless light source is provided. The light source comprises a hollow, elongated chamber and at least one center conductor disposed within the hollow, elongated chamber. A portion of each center conductor extends beyond the hollow, elongated chamber. At least one gas capable of forming an electronically excited molecular state is contained within each center conductor. An electrical coupler is positioned concentric to the hollow, elongated chamber and the electrical coupler surrounds the portion of each center conductor that extends beyond the hollow, elongated chamber. A rf-power supply is positioned in an operable relationship to the electrical couplermore » and an impedance matching network is positioned in an operable relationship to the rf power supply and the electrical coupler.« less
A tandem mirror hybrid plume plasma propulsion facility
NASA Technical Reports Server (NTRS)
Yang, T. F.; Krueger, W. A.; Peng, S.; Urbahn, J.; Chang-Diaz, F. R.
1988-01-01
This paper discusses a novel concept in electrodeless plasma propulsion, in which the materials problems are ameliorated by an electrodeless magnetic confinement scheme borrowed from the tandem mirror approach to controlled thermonuclear fusion. The concept also features a two-stage magnetic nozzle with an annular hypersonic coaxial gas injector near the throat. The nozzle produces hybrid plume by the coaxial injection of hypersonic neutral gas, and the gas layer thus formed protects the material walls from the hot plasma and, through increased collisions, helps detach it from the diverging magnetic field. The tandem mirror plasma propulsion facility is capable of delivering a variable I(sp). The results of numerical simulation of this concept are presented together with those from an experimental tandem-mirror plasma propulsion device.
MacLennan, Donald A.; Turner, Brian P.; Gitsevich, Aleksandr; Bass, Gary K.; Dolan, James T.; Kipling, Kent; Kirkpatrick, Douglas A.; Leng, Yongzhang; Levin, Izrail; Roy, Robert J.; Shanks, Bruce; Smith, Malcolm; Trimble, William C.; Tsai, Peter
2001-01-01
A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.
30 CFR 20.7 - Specific requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... lamps, inspection lamps, flashlights, and animal lamps which are operated by small storage batteries or dry cells. (b) Class 2. Class 2 includes lamps such as the pneumatic-electric types and large battery...
30 CFR 20.7 - Specific requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... lamps, inspection lamps, flashlights, and animal lamps which are operated by small storage batteries or dry cells. (b) Class 2. Class 2 includes lamps such as the pneumatic-electric types and large battery...
30 CFR 20.7 - Specific requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... lamps, inspection lamps, flashlights, and animal lamps which are operated by small storage batteries or dry cells. (b) Class 2. Class 2 includes lamps such as the pneumatic-electric types and large battery...
30 CFR 20.7 - Specific requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... lamps, inspection lamps, flashlights, and animal lamps which are operated by small storage batteries or dry cells. (b) Class 2. Class 2 includes lamps such as the pneumatic-electric types and large battery...
The Effects of Lamp Spectral Distribution on Sky Glow over Observatories
2015-01-01
overhead sky glow as a function of distance up to 300 km, from a variety of lamp types, including common gas discharge lamps and several types of LED...distance up to 300 km, from a variety of lamp types, in- cluding common gas discharge lamps and several types of LED lamps . We conclude for both...MAR 2015 2. REPORT TYPE 3. DATES COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE The Effects of Lamp Spectral Distribution on Sky Glow
NASA Technical Reports Server (NTRS)
Yi, Lin (Inventor); Tjoelker, Robert L. (Inventor); Burt, Eric A. (Inventor); Huang, Shouhua (Inventor)
2016-01-01
Hollow-core capillary discharge lamps on the millimeter or sub-millimeter scale are provided. The hollow-core capillary discharge lamps achieve an increased light intensity ratio between 194 millimeters (useful) and 254 millimeters (useless) light than conventional lamps. The capillary discharge lamps may include a cone to increase light output. Hollow-core photonic crystal fiber (HCPCF) may also be used.
Electrodeless RF Plasma Thruster Using m = 0 Coil
NASA Astrophysics Data System (ADS)
Nishimura, Shuichi; Arai, Daisuke; Kuwahara, Daisuke; Shinohara, Shunjiro
2016-10-01
In order to realize a deep space exploration in the future, we have been developing a next generation electrodeless electric propulsion system by electromagnetic acceleration of high-density helicon plasma. A new proposed method by m = 0 coil plasma acceleration (m is an azimuthal mode number) is based on the Lorentz force: a product of the induced azimuthal current by supplying an AC current to the m = 0 coil and the radial component of the externally applied magnetic field (divergent field configuration). Here, we have investigated the dependences of an ion velocity and an electron density on the external parameters, leading to optimized conditions, using the SHD device. By increasing AC current on the order of 100 A, we could see the increase of ion velocity and electron density by a factor of 2.5 and 3, respectively.
Siminovitch, Michael
1998-01-01
A novel design for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment.
Heat transfer assembly for a fluorescent lamp and fixture
Siminovitch, Michael J.; Rubenstein, Francis M.; Whitman, Richard E.
1992-01-01
In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.
Lamp with a truncated reflector cup
Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel
2013-10-15
A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.
Siminovitch, M.
1998-02-10
A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-12
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,767] General Electric Lighting-Ravenna Lamp Plant, Lighting Division, Including On-Site Leased Workers from Devore Technologies, Ravenna..., 2009, applicable to workers of General Electric Lighting-Ravenna Lamp Plant, Lighting Division...
30 CFR 20.7 - Specific requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... that are self-contained and easily carried by hand, and class 2, those that may or may not be self... lamps, inspection lamps, flashlights, and animal lamps which are operated by small storage batteries or dry cells. (b) Class 2. Class 2 includes lamps such as the pneumatic-electric types and large battery...
Improved xenon lamp for solar simulators: A concept
NASA Technical Reports Server (NTRS)
Schmidt, L. F.
1974-01-01
Short-arc xenon lamp proposes to produce more uniform solar output. With this lamp, both axes of sensors can be tested with same setup. Lamp includes cathode with conical tip and annular anode. Annulus is supported by angled projection to avoid interference with passage of light generated by arc.
Heat transfer assembly for a fluorescent lamp and fixture
Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.
1992-12-29
In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.
Chen, Daqi; Sun, Xiyang; Zhang, Kaihuan; Fan, Guokang; Wang, You; Li, Guang; Hu, Ruifen
2017-07-21
Dibutyl phthalate (DBP) is a widely used plasticizer which has been found to be a reproductive and developmental toxicant and ubiquitously existing in the air. A highly sensitive method for DBP monitoring in the environment is urgently needed. A DBP sensor based on a homemade wireless-electrodeless quartz crystal microbalance with dissipation (QCM-D) coated with nano-structured nickel hydroxide is presented. With the noncontact configuration, the sensing system could work at a higher resonance frequency (the 3rd overtone) and the response of the system was even more stable compared with a conventional quartz crystal microbalance (QCM). The sensor achieved a sensitivity of 7.3 Hz/ppb to DBP in a concentration range of 0.4-40 ppb and an ultra-low detection limit of 0.4 ppb of DBP has also been achieved.
Testing Done for Lorentz Force Accelerators and Electrodeless Propulsion Technology Development
NASA Technical Reports Server (NTRS)
Pencil, Eric J.; Gilland, James H.; Arrington, Lynn A.; Kamhawi, Hani
2004-01-01
The NASA Glenn Research Center is developing Lorentz force accelerators and electrodeless plasma propulsion for a wide variety of space applications. These applications range from precision control of formation-flying spacecraft to primary propulsion for very high power interplanetary spacecraft. The specific thruster technologies being addressed are pulsed plasma thrusters, magnetoplasmadynamic thrusters, and helicon-electron cyclotron resonance acceleration thrusters. The pulsed plasma thruster mounted on the Earth Observing-1 spacecraft was operated successfully in orbit in 2002. The two-axis thruster system is fully incorporated in the attitude determination and control system and is being used to automatically counteract disturbances in the pitch axis of the spacecraft. Recent on-orbit operations have focused on extended operations to add flight operation time to the total accumulated thruster life. The results of the experiments pave the way for electric propulsion applications on future Earth-imaging satellites.
Sun, Xiyang; Zhang, Kaihuan; Fan, Guokang; Wang, You; Li, Guang; Hu, Ruifen
2017-01-01
Dibutyl phthalate (DBP) is a widely used plasticizer which has been found to be a reproductive and developmental toxicant and ubiquitously existing in the air. A highly sensitive method for DBP monitoring in the environment is urgently needed. A DBP sensor based on a homemade wireless-electrodeless quartz crystal microbalance with dissipation (QCM-D) coated with nano-structured nickel hydroxide is presented. With the noncontact configuration, the sensing system could work at a higher resonance frequency (the 3rd overtone) and the response of the system was even more stable compared with a conventional quartz crystal microbalance (QCM). The sensor achieved a sensitivity of 7.3 Hz/ppb to DBP in a concentration range of 0.4–40 ppb and an ultra-low detection limit of 0.4 ppb of DBP has also been achieved. PMID:28753974
21 CFR 878.4635 - Ultraviolet lamp for tanning.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultraviolet lamp for tanning. 878.4635 Section 878... tanning. (a) Identification. An ultraviolet lamp for tanning is a device that is a lamp (including a fixture) intended to provide ultraviolet radiation to tan the skin. See § 1040.20 of this chapter. (b...
The fate and management of high mercury-containing lamps from high technology industry.
Chang, T C; You, S J; Yu, B S; Kong, H W
2007-03-22
This study investigated the fate and management of high mercury-contained lamps, such as cold cathode fluorescent lamps (CCFLs), ultraviolet lamps (UV lamps), and super high pressure mercury lamps (SHPs), from high technology industries in Taiwan, using material flow analysis (MFA) method. Several organizations, such as Taiwan Environmental Protection Administration, Taiwan External Trade Development Council, the light sources manufactories, mercury-containing lamps importer, high technology industrial user, and waste mercury-containing lamps treatment facilities were interviewed in this study. According to this survey, the total mercury contained in CCFLs, UV lamps, and SHPs produced in Taiwan or imported from other countries was 886kg in year 2004. Among the various lamps containing mercury, 57kg mercury was exported as primary CCFLs, 7kg mercury was wasted as defective CCFLs, and 820kg mercury was used in the high technology industries, including 463kg mercury contained in exported industrial products using CCFLs as components. On the contrary, only 59kg of mercury was exported, including 57kg in CCFLs and 2kg in UV lamps. It reveals that 364kg mercury was consumed in Taiwan during year 2004. In addition, 140kg of the 364kg mercury contained in lamps used by high technology industry was well treated through industrial waste treatment system. Among the waste mercury from high technology industry, 80kg (57%), 53kg (38%), and 7kg (5%) of mercury were through domestic treatment, offshore treatment, and emission in air, respectively. Unfortunately, 224kg waste mercury was not suitable treated, including 199kg mercury contained in CCFL, which is a component of monitor for personal computer and liquid crystal display television, and 25kg non-treated mercury. Thus, how to recover the mercury from the waste monitors is an important challenge of zero wastage policy in Taiwan.
A slit-lamp, which is a specialized magnifying microscope, is used to examine the structures of the eye (including the cornea, iris, vitreous, and retina). The slit-lamp is used to examine, treat (with a laser), ...
Direct current ballast circuit for metal halide lamp
NASA Technical Reports Server (NTRS)
Lutus, P. (Inventor)
1981-01-01
A direct current ballast circuit for a two electrode metal halide lamp is described. Said direct current ballast circuit includes a low voltage DC input and a high frequency power amplifier and power transformer for developing a high voltage output. The output voltage is rectified by diodes and filtered by inductor and capacitor to provide a regulated DC output through commutating diodes to one terminal of the lamp at the output terminal. A feedback path from the output of the filter capacitor through the bias resistor to power the high frequency circuit which includes the power amplifier and the power transformer for sustaining circuit operations during low voltage transients on the input DC supply is described. A current sensor connected to the output of the lamp through terminal for stabilizing lamp current following breakdown of the lamp is described.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-12
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,714] Arkansas Lamp Manufacturing, Including On-Site Leased Workers From TEC, Van Buren, AR; Notice of Termination of Investigation... a petition filed on July 17, 2009, by a company official on behalf of workers of Arkansas Lamp...
Blue-green phosphor for fluorescent lighting applications
Srivastava, Alok; Comanzo, Holly; Manivannan, Venkatesan; Setlur, Anant Achyut
2005-03-15
A fluorescent lamp including a phosphor layer including Sr.sub.4 Al.sub.14 O.sub.25 :Eu.sup.2+ (SAE) and at least one of each of a red, green and blue emitting phosphor. The phosphor layer can optionally include an additional, deep red phosphor and a yellow emitting phosphor. The resulting lamp will exhibit a white light having a color rendering index of 90 or higher with a correlated color temperature of from 2500 to 10000 Kelvin. The use of SAE in phosphor blends of lamps results in high CRI light sources with increased stability and acceptable lumen maintenance over, the course of the lamp life.
Arc lamp power supply using a voltage multiplier
NASA Technical Reports Server (NTRS)
Leighty, Bradley D.
1988-01-01
A power supply is provided for an arc discharge lamp which includes a relatively low voltage high current power supply section and a high voltage starter circuit. The low voltage section includes a transformer, rectifier, variable resistor and a bank of capacitors, while the starter circuit comprises several diodes and capacitors connected as a Cockcroft-Walton multiplier. The starting circuit is effectively bypassed when the lamp arc is established and serves to automatically provide a high starting voltage to re-strike the lamp arc if the arc is extinguished by a power interruption.
Convection venting lensed reflector-type compact fluorescent lamp system
Pelton, B.A.; Siminovitch, M.
1997-07-29
Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.
Convection venting lensed reflector-type compact fluorescent lamp system
Pelton, Bruce A.; Siminovitch, Michael
1997-01-01
Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures.
Lee, Eun-Ju; Park, Kwan-Sik; Jeon, In-Sook; Choi, Jae-Woon; Lee, Sang-Jeon; Choy, Hyun E; Song, Ki-Duk; Lee, Hak-Kyo; Choi, Joong-Kook
2016-07-01
Lysosomes are cellular organelles containing diverse classes of catabolic enzymes that are implicated in diverse cellular processes including phagocytosis, autophagy, lipid transport, and aging. Lysosome-associated membrane proteins (LAMP-1 and LAMP-2) are major glycoproteins important for maintaining lysosomal integrity, pH, and catabolism. LAMP-1 and LAMP-2 are constitutively expressed in Salmonella-infected cells and are recruited to Salmonella-containing vacuoles (SCVs) as well as Salmonella-induced filaments (Sifs) that promote the survival and proliferation of the Salmonella. LAMP-3, also known as DC-LAMP/CD208, is a member of the LAMP family of proteins, but its role during Salmonella infection remains unclear. DNA microarray analysis identified LAMP-3 as one of the genes responding to LPS stimulation in THP-1 macrophage cells. Subsequent analyses reveal that LPS and Salmonella induced the expression of LAMP-3 at both the transcriptional and translational levels. Confocal Super resolution N-SIM imaging revealed that LAMP-3, like LAMP-2, shifts its localization from the cell surface to alongside Salmonella. Knockdown of LAMP-3 by specific siRNAs decreased the number of Salmonella recovered from the infected cells. Therefore, we conclude that LAMP-3 is induced by Salmonella infection and recruited to the Salmonella pathogen for intracellular proliferation.
Lee, Eun-Ju; Park, Kwan-Sik; Jeon, In-Sook; Choi, Jae-Woon; Lee, Sang-Jeon; Choy, Hyun E.; Song, Ki-Duk; Lee, Hak-Kyo; Choi, Joong-Kook
2016-01-01
Lysosomes are cellular organelles containing diverse classes of catabolic enzymes that are implicated in diverse cellular processes including phagocytosis, autophagy, lipid transport, and aging. Lysosome-associated membrane proteins (LAMP-1 and LAMP-2) are major glycoproteins important for maintaining lysosomal integrity, pH, and catabolism. LAMP-1 and LAMP-2 are constitutively expressed in Salmonella-infected cells and are recruited to Salmonella-containing vacuoles (SCVs) as well as Salmonella-induced filaments (Sifs) that promote the survival and proliferation of the Salmonella. LAMP-3, also known as DC-LAMP/CD208, is a member of the LAMP family of proteins, but its role during Salmonella infection remains unclear. DNA microarray analysis identified LAMP-3 as one of the genes responding to LPS stimulation in THP-1 macrophage cells. Subsequent analyses reveal that LPS and Salmonella induced the expression of LAMP-3 at both the transcriptional and translational levels. Confocal Super resolution N-SIM imaging revealed that LAMP-3, like LAMP-2, shifts its localization from the cell surface to alongside Salmonella. Knockdown of LAMP-3 by specific siRNAs decreased the number of Salmonella recovered from the infected cells. Therefore, we conclude that LAMP-3 is induced by Salmonella infection and recruited to the Salmonella pathogen for intracellular proliferation. PMID:27329040
Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures
Siminovitch, Michael J.
1992-01-01
In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface.
Types of Lamp for Homework and Myopia among Chinese School-Aged Children.
Pan, Chen-Wei; Wu, Rong-Kun; Liu, Hu; Li, Jun; Zhong, Hua
2018-06-01
We aim to determine the association of the types of lamp for homework including incandescent lamp, fluorescent lamp, and light-emitting diode (LED) lamp with the prevalence of myopia in Chinese children. 2346 grade 7 students from ten middle schools (93.5% response rate) aged 13 to 14 years in Mojiang, a small county located in Southwestern China, participated in the study. Refractive error was measured with cycloplegia using an autorefractor by optometrists or trained technicians. An IOL Master was used to measure ocular biometric parameters including axial length (AL). Information regarding the types of lamp for homework af``ter schools was collected by questionnaires. Of all the study participants, 693 (29.5%) were affected by myopia, with the prevalence estimates being higher in girls (36.8%; 95% confidence interval [CI]: 34.0, 39.6) than in boys (22.8%; 95% CI: 20.4, 25.1) (P < 0.001). After adjusting for potential confounders such as gender, height, parental history of myopia, time on computer use, time on watching TV, time outdoors, and time on reading and writing, participants using LED lamps for homework had a more myopic refractive error and a longer AL compared with those using incandescent or fluorescent lamps. There were no significant differences in myopia prevalence between children using incandescent and fluorescent lamps for homework. The population attributable risk percentage for myopia associated with using LED lamps for homework after schools was 11.2%. Using LED lamps for homework after schools might contribute to the development of myopia among school-aged children.
Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures
Siminovitch, M.J.
1992-11-10
In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface. 12 figs.
Arita, Minetaro; Ling, Hua; Yan, Dongmei; Nishimura, Yorihiro; Yoshida, Hiromu; Wakita, Takaji; Shimizu, Hiroyuki
2009-12-16
In the global eradication program for poliomyelitis, the laboratory diagnosis plays a critical role by isolating poliovirus (PV) from the stool samples of acute flaccid paralysis (AFP) cases. In this study, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a rapid and highly sensitive detection of enterovirus including PV to identify stool samples positive for enterovirus including PV. A primer set was designed for RT-LAMP to detect enterovirus preferably those with PV-like 5'NTRs of the viral genome. The sensitivity of RT-LAMP system was evaluated with prototype strains of enterovirus. Detection of enterovirus from stool extracts was examined by using RT-LAMP system. We detected at least 400 copies of the viral genomes of PV(Sabin) strains within 90 min by RT-LAMP with the primer set. This RT-LAMP system showed a preference for Human enterovirus species C (HEV-C) strains including PV, but exhibited less sensitivity to the prototype strains of HEV-A and HEV-B (detection limits of 7,400 to 28,000 copies). Stool extracts, from which PV, HEV-C, or HEV-A was isolated in the cell culture system, were mostly positive by RT-LAMP method (positive rates of 15/16 (= 94%), 13/14 (= 93%), and 4/4 (= 100%), respectively). The positive rate of this RT-LAMP system for stool extracts from which HEV-B was isolated was lower than that of HEV-C (positive rate of 11/21 (= 52%)). In the stool samples, which were negative for enterovirus isolation by the cell culture system, we found that two samples were positive for RT-LAMP (positive rates of 2/38 (= 5.3%)). In these samples, enterovirus 96 was identified by sequence analysis utilizing a seminested PCR system. RT-LAMP system developed in this study showed a high sensitivity comparable to that of the cell culture system for the detection of PV, HEV-A, and HEV-C, but less sensitivity to HEV-B. This RT-LAMP system would be useful for the direct detection of enterovirus from the stool extracts.
Understanding anode and cathode behaviour in high-pressure discharge lamps
NASA Astrophysics Data System (ADS)
Flesch, P.; Neiger, M.
2005-09-01
High-intensity discharge (HID) lamps have widespread and modern areas of application including general lighting, video/movie projection (e.g. UHP lamp), street/industrial lighting, and automotive headlight lamps (D2/xenon lamp). Even though HID lamps have been known for several decades now, the important plasma-electrode interactions are still not well understood. Because HID lamps are usually operated on ac (electrodes switch alternately from anode to cathode phase), time-dependent simulations including realistic and verified anode and cathode models are essential. Therefore, a recently published investigation of external laser heating of an electrode during anode and cathode phase in an operating HID lamp [28] provided the basis for our present paper. These measurements revealed impressive influences of the external laser heating on electrode fall voltage and electrode temperature. Fortunately, the effects are very different during anode and cathode phase. Thus, by comparing the experimental findings with results from our numerical simulations we can learn much about the principles of electrode behaviour and explain in detail the differences between anode and cathode phase. Furthermore, we can verify our model (which includes plasma column, hot plasma spots in front of the electrodes, constriction zones and near-electrode non-local thermal equilibrium-plasma as well as anode and cathode) that accounts for all relevant physical processes concerning plasma, electrodes and interactions between them. Moreover, we investigate the influence of two different notions concerning ionization and recombination in the near electrode plasma on the numerical results. This improves our physical understanding of near-electrode plasma likewise and further increases the confidence in the model under consideration. These results are important for the understanding and the further development of HID lamps which, due to their small dimensions, are often experimentally inaccessible. Thus, modelling becomes more and more important.
Guidelines for application of fluorescent lamps in high-performance avionic backlight systems
NASA Astrophysics Data System (ADS)
Syroid, Daniel D.
1997-07-01
Fluorescent lamps have proven to be well suited for use in high performance avionic backlight systems as demonstrated by numerous production applications for both commercial and military cockpit displays. Cockpit display applications include: Boeing 777, new 737s, F-15, F-16, F-18, F-22, C- 130, Navy P3, NASA Space Shuttle and many others. Fluorescent lamp based backlights provide high luminance, high lumen efficiency, precision chromaticity and long life for avionic active matrix liquid crystal display applications. Lamps have been produced in many sizes and shapes. Lamp diameters range from 2.6 mm to over 20 mm and lengths for the larger diameter lamps range to over one meter. Highly convoluted serpentine lamp configurations are common as are both hot and cold cathode electrode designs. This paper will review fluorescent lamp operating principles, discuss typical requirements for avionic grade lamps, compare avionic and laptop backlight designs and provide guidelines for the proper application of lamps and performance choices that must be made to attain optimum system performance considering high luminance output, system efficiency, dimming range and cost.
Fast repetition rate (FRR) flasher
Kolber, Zbigniew; Falkowski, Paul
1997-02-11
A fast repetition rate (FRR) flasher suitable for high flash photolysis including kinetic chemical and biological analysis. The flasher includes a power supply, a discharge capacitor operably connected to be charged by the power supply, and a flash lamp for producing a series of flashes in response to discharge of the discharge capacitor. A triggering circuit operably connected to the flash lamp initially ionizes the flash lamp. A current switch is operably connected between the flash lamp and the discharge capacitor. The current switch has at least one insulated gate bipolar transistor for switching current that is operable to initiate a controllable discharge of the discharge capacitor through the flash lamp. Control means connected to the current switch for controlling the rate of discharge of the discharge capacitor thereby to effectively keep the flash lamp in an ionized state between Successive discharges of the discharge capacitor. Advantageously, the control means is operable to discharge the discharge capacitor at a rate greater than 10,000 Hz and even up to a rate greater than about 250,000 Hz.
Nanostructured metal-polyaniline composites
Wang, Hsing-Lin; Li, Wenguang; Bailey, James A.; Gao, Yuan
2010-08-31
Metal-polyaniline (PANI) composites are provided together with a process of preparing such composites by an electrodeless process. The metal of the composite can have nanoscale structural features and the composites can be used in applications such as catalysis for hydrogenation reactions and for analytical detection methods employing SERS.
Chiou, Chi-Han; Pan, Jia-Cheng; Chien, Liang-Ju; Lin, Yu-Ying; Lin, Jr-Lung
2013-01-01
This study demonstrated the feasibility of utilizing electrokinesis in an electrodeless dielectrophoresis chip to separate and concentrate microparticles such as biosamples. Numerical simulations and experimental observations were facilitated to investigate the phenomena of electrokinetics, i.e., electroosmosis, dielectrophoresis, and electrothermosis. Moreover, the proposed operating mode can be used to simultaneously convey microparticles through a microfluidic device by using electroosmotic flow, eliminating the need for an additional micropump. These results not only revealed that the directions of fluids could be controlled with a forward/backward electroosmotic flow but also categorized the optimum separating parameters for various microparticle sizes (0.5, 1.0 and 2.0 μm). Separation of microparticles can be achieved by tuning driving frequencies at a specific electric potential (90 Vpp·cm−1). Certainly, the device can be designed as a single automated device that carries out multiple functions such as transportation, separation, and detection for the realization of the envisioned Lab-on-a-Chip idea. PMID:23447009
Miccio, L; Finizio, A; Grilli, S; Vespini, V; Paturzo, M; De Nicola, S; Ferraro, Pietro
2009-02-16
A special class of tunable liquid microlenses is presented here. The microlenses are generated by an electrowetting effect under an electrode-less configuration and they exhibit two different regimes that are named here as separated lens regime (SLR) and wave-like lens regime (WLR). The lens effect is induced by the pyroelectricity of polar dielectric crystals, as was proved in principle in a previous work by the same authors (S. Grilli et al., Opt. Express 16, 8084, 2008). Compared to that work, the improvements to the experimental set-up and procedure allow to reveal the two lens regimes which exhibit different optical properties. A digital holography technique is used to reconstruct the transmitted wavefront during focusing and a focal length variation in the millimetre range is observed. The tunability of such microlenses could be of great interest to the field of micro-optics thanks to the possibility to achieve focus tuning without moving parts and thus favouring the miniaturization of the optical systems.
NASA Astrophysics Data System (ADS)
Shinohara, S.; Nishida, H.; Nakamura, T.; Mishio, A.; Ishii, H.; Teshigahara, N.; Fujitsuka, H.; Waseda, S.; Tanikawa, T.; Hada, T.; Otsuka, F.; Funaki, I.; Matsuoka, T.; Shamrai, K.; Rudenko, T.
2012-10-01
High-density but low temperature helicon plasmas have been proved to be very useful for fundamental research as well as for various applications. First, we introduce our very large helicon sources [1] with a diameter up to 74 cm. For the industrial and propulsion applications, we have reduced the aspect ratio (axial length-to-diameter) down to 0.075, and examined the discharge performance and wave characteristics. Then, we discuss our small helicon sources [1] for developing new electrodeless acceleration schemes. Some experimental and theoretical results [2] by applying the rotating magnetic (or electric) fields to the helicon plasma under the divergent magnetic field will be presented, along with other propulsion schemes. In addition, an initial plasma production experiment with very small diameter will be described.[4pt] [1] S. Shinohara et al., Jpn. J. Appl. Phys. 35 (1996) 4503; Rev. Sci. Instrum. 75 (2004) 1941; Phys. Plasmas 16 (2009) 057104.[0pt] [2] S. Shinohara et al., 32th Int. Electric Propul. Conf., IEPC-2011-056, 2011.
Apparatus for isotopic alteration of mercury vapor
Grossman, Mark W.; George, William A.; Marcucci, Rudolph V.
1988-01-01
An apparatus for enriching the isotopic Hg content of mercury is provided. The apparatus includes a reactor, a low pressure electric discharge lamp containing a fill including mercury and an inert gas. A filter is arranged concentrically around the lamp. In a preferred embodiment, constant mercury pressure is maintained in the filter by means of a water-cooled tube that depends from it, the tube having a drop of mercury disposed in it. The reactor is arranged around the filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of a material which is transparent to ultraviolet light.
Ahmed, Mohamed E; Eldigail, Mawahib H; Elamin, Fatima M; Ali, Ibtisam A; Grobusch, Martin P; Aradaib, Imadeldin E
2016-09-13
Cystic echinococcosis (CE) or hydatidosis, caused by the larval stage of Echinococcus granulosus (EG)-complex, is a neglected parasitic disease of public health importance. The disease is endemic in many African and Mediterranean countries including the Sudan. The objective of the present study was to develop and evaluate a real-time loop-mediated isothermal amplification (LAMP) assay for simple and rapid detection of CE in humans and domestic live stock in Sudan. A set of six LAMP primers, designed from the mitochondrial NADH-1 gene of EG cattle strain of genotype 5 (G5), was used as a target for LAMP assay. The assay was performed at a constant temperature (63 °C), with a real-time follow-up using a LightCycler and fluorochrome dye. Following amplification cycles in a simple water bath, LAMP products were observed for color change by naked eye and were visualized under UV light source using agarose gel electrophoresis. The real-time LAMP assay identified a variety of hydatid cysts strains recovered in the Sudan, including Echinococcus canadenses (G6) and Echinococcus ortleppi (G5). Real-time LAMP positive results were detected by the presence of an amplification curve, whereas negative results were indicated by absence of fluorescence detection. Positive LAMP results appeared as a bluish-colored reaction as observed by naked eye, whereas negative LAMP results were observed as purple-colored reaction. The sensitivity studies indicated that the LAMP assay detected as little as a 10 fg of parasite DNA. There was 100 % agreement between results of the LAMP assay and our previously described nested PCR when testing 10-fold serial dilution of DNA extracted from EG-complex hydatid cyst. However, there was no cross-reactivity with other parasites including cysticercus bovis, Fasciola gigantica, and Schistosoma bovis and nucleic acid free samples. The developed LAMP assay would be expected to prove highly significant in epidemiological surveys of CE in developing countries or areas of resource-poor settings for both ease of use and cost.
2009-01-01
Background In the global eradication program for poliomyelitis, the laboratory diagnosis plays a critical role by isolating poliovirus (PV) from the stool samples of acute flaccid paralysis (AFP) cases. In this study, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a rapid and highly sensitive detection of enterovirus including PV to identify stool samples positive for enterovirus including PV. Methods A primer set was designed for RT-LAMP to detect enterovirus preferably those with PV-like 5'NTRs of the viral genome. The sensitivity of RT-LAMP system was evaluated with prototype strains of enterovirus. Detection of enterovirus from stool extracts was examined by using RT-LAMP system. Results We detected at least 400 copies of the viral genomes of PV(Sabin) strains within 90 min by RT-LAMP with the primer set. This RT-LAMP system showed a preference for Human enterovirus species C (HEV-C) strains including PV, but exhibited less sensitivity to the prototype strains of HEV-A and HEV-B (detection limits of 7,400 to 28,000 copies). Stool extracts, from which PV, HEV-C, or HEV-A was isolated in the cell culture system, were mostly positive by RT-LAMP method (positive rates of 15/16 (= 94%), 13/14 (= 93%), and 4/4 (= 100%), respectively). The positive rate of this RT-LAMP system for stool extracts from which HEV-B was isolated was lower than that of HEV-C (positive rate of 11/21 (= 52%)). In the stool samples, which were negative for enterovirus isolation by the cell culture system, we found that two samples were positive for RT-LAMP (positive rates of 2/38 (= 5.3%)). In these samples, enterovirus 96 was identified by sequence analysis utilizing a seminested PCR system. Conclusions RT-LAMP system developed in this study showed a high sensitivity comparable to that of the cell culture system for the detection of PV, HEV-A, and HEV-C, but less sensitivity to HEV-B. This RT-LAMP system would be useful for the direct detection of enterovirus from the stool extracts. PMID:20015403
Siminovitch, Michael J.; Page, Erik R.
2002-01-01
A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.
Low pressure arc discharge lamp apparatus with magnetic field generating means
Grossman, Mark W.; George, William A.; Maya, Jakob
1987-01-01
A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25.degree. C.
Huy, Nguyen Tien; Hang, Le Thi Thuy; Boamah, Daniel; Lan, Nguyen Thi Phuong; Van Thanh, Phan; Watanabe, Kiwao; Huong, Vu Thi Thu; Kikuchi, Mihoko; Ariyoshi, Koya; Morita, Kouichi; Hirayama, Kenji
2012-12-01
Several loop-mediated isothermal amplification (LAMP) assays have been developed to detect common causative pathogens of bacterial meningitis (BM). However, no LAMP assay is reported to detect Streptococcus agalactiae and Streptococcus suis, which are also among common pathogens of BM. Moreover, it is laborious and expensive by performing multiple reactions for each sample to detect bacterial pathogen. Thus, we aimed to design and develop a single-tube LAMP assay capable of detecting multiple bacterial species, based on the nucleotide sequences of the 16S rRNA genes of the bacteria. The nucleotide sequences of the 16S rRNA genes of main pathogens involved in BM were aligned to identify conserved regions, which were further used to design broad range specific LAMP assay primers. We successfully designed a set of broad range specific LAMP assay primers for simultaneous detection of four species including Staphylococcus aureus, Streptococcus pneumoniae, S. suis and S. agalactiae. The broad range LAMP assay was highly specific without cross-reactivity with other bacteria including Haemophilus influenzae, Neisseria meningitidis and Escherichia coli. The sensitivity of our LAMP assay was 100-1000 times higher compared with the conventional PCR assay. The bacterial species could be identified after digestion of the LAMP products with restriction endonuclease DdeI and HaeIII. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.
Takeuchi, Sora; Kimura, Satoko; Soma, Yoshinao; Waki, Masashi; Yamaguchi, Madoka; Nakazawa, Daigo; Tomaru, Utano; Ishizu, Akihiro; Kawakami, Tamihiro
2013-09-01
Recent research suggests that lysosomal-associated membrane protein-2 (LAMP-2) could be one of the target antigens in the pathogenesis of vasculitides. We established a transgenic rat model, env-pX rats, with various vasculitides including cutaneous vasculitis. Human primary cutaneous vasculitis includes cutaneous polyarteritis nodosa (CPN) and Henoch-Schönlein purpura (HSP). We measured serum anti-LAMP-2 antibody levels in morbid env-pX rats and injected anti-LAMP-2 antibody into premorbid env-pX rats. We further measured serum anti-LAMP-2 antibody levels in patients with CPN and HSP. Cutaneous vasculitis was observed in ∼30% of 6-month-old morbid env-pX rats. In contrast, these findings were rare in premorbid env-pX rats under 3 months old. We also examined 85 patients with CPN and 36 adult patients with HSP. Serum anti-LAMP-2 antibody levels were determined using ELISA. Premorbid env-pX rats under 3 months old were given an i.v. injection of anti-LAMP-2 antibody at day 0 and day 7. At day 14, these rats underwent histopathological and direct immunofluorescence examination. Cell surface LAMP-2 expression of rat neutrophils was examined by flow cytometry. Serum anti-LAMP-2 antibody levels were significantly higher in morbid env-pX rats than in wild-type normal rats. In addition, the levels in the cutaneous vasculitis group of morbid env-pX rats were significantly higher than the no cutaneous vasculitis group. Intravenous anti-LAMP-2 antibody injection into premorbid env-pX rats under 3 months old induced infiltration of neutrophils into cutaneous small vessels. Anti-LAMP-2 antibody-binding neutrophils were detected there. LAMP-2 expression on the cell surface of neutrophils in premorbid env-pX rats under PMA stimulation was higher compared with controls. Serum anti-LAMP-2 antibody levels in CPN and HSP were significantly higher than those of healthy controls. These data support a positive relationship between anti-LAMP-2 antibody and cutaneous vasculitis.
Primer of School Lighting Lamps and Maintenance.
ERIC Educational Resources Information Center
Allphin, Willard
The basic principles of the most commonly used lamp types and the circuitry which makes them operate are discussed. The two objectives of this book are to serve as a--(1) guide to economical lighting, and (2) a permanent reference source for troubleshooting. Areas dealt with include--(1) lighting fundamentals, (2) incandescent lamps, (3)…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
... of R20 Short Lamps and Unavailability of Substitutes D. Request for Information I. Background The... or has special characteristics not available in substitute lamp types. Specifically, as the lamp has... manufacturers (including designated beam spread and lumen output), there are no substitute products on the...
ERIC Educational Resources Information Center
Valett, Robert E.
Research findings on auditory sequencing and auditory blending and fusion, auditory-visual integration, and language patterns are presented in support of the Linguistic Auditory Memory Patterns (LAMP) program. LAMP consists of 100 developmental lessons for young students with learning disabilities or language problems. The lessons are included in…
Transitioning to College and Career: Interim Findings of the LAMP Longitudinal Study.
ERIC Educational Resources Information Center
MacAllum, Keith; Worgs, Donn; Bozick, Robert; McDonald, Deanne
The Lansing Area Manufacturing Partnership (LAMP) is an academically rigorous, business/labor-driven school-to-career program in Lansing, Michigan, that includes business, union, school, and parent partners. The effects of participation in LAMP on transitions from school to higher education and work were examined in a longitudinal study that…
Red phosphors for use in high CRI fluorescent lamps
Srivastava, Alok; Comanzo, Holly; Manivannan, Vankatesan; Setlur, Anant Achyut
2005-11-15
Novel red emitting phosphors for use in fluorescent lamps resulting in superior color rendering index values compared to conventional red phosphors. Also disclosed is a fluorescent lamp including a phosphor layer comprising blends of one or more of a blue phosphor, a blue-green phosphor, a green phosphor and a red a phosphor selected from the group consisting of SrY.sub.2 O.sub.4 :Eu.sup.3+, (Y,Gd)Al.sub.3 B.sub.4 O.sub.12 :Eu.sup.3+, and [(Y.sub.1-x-y-m La.sub.y)Gd.sub.x ]BO.sub.3 :Eu.sub.m wherein y<0.50 and m=0.001-0.3. The phosphor layer can optionally include an additional deep red phosphor and a yellow emitting phosphor. The resulting lamp will exhibit a white light having a color rendering index of 90 or higher with a correlated color temperature of from 2500 to 10000 Kelvin. The use of the disclosed red phosphors in phosphor blends of lamps results in high CRI light sources with increased stability and acceptable lumen maintenance over the course of the lamp life.
Fast repetition rate (FRR) flasher
Kolber, Z.; Falkowski, P.
1997-02-11
A fast repetition rate (FRR) flasher is described suitable for high flash photolysis including kinetic chemical and biological analysis. The flasher includes a power supply, a discharge capacitor operably connected to be charged by the power supply, and a flash lamp for producing a series of flashes in response to discharge of the discharge capacitor. A triggering circuit operably connected to the flash lamp initially ionizes the flash lamp. A current switch is operably connected between the flash lamp and the discharge capacitor. The current switch has at least one insulated gate bipolar transistor for switching current that is operable to initiate a controllable discharge of the discharge capacitor through the flash lamp. Control means connected to the current switch for controlling the rate of discharge of the discharge capacitor thereby to effectively keep the flash lamp in an ionized state between successive discharges of the discharge capacitor. Advantageously, the control means is operable to discharge the discharge capacitor at a rate greater than 10,000 Hz and even up to a rate greater than about 250,000 Hz. 14 figs.
Nanostructured metal-polyaniline composites and applications thereof
Wang, Hsing-Lin; Li, Wenguang; Bailey, James A.; Gao, Yuan
2012-10-02
Metal-polyaniline (PANI) composites are provided together with a process of preparing such composites by an electrodeless process. The metal of the composite can have nanoscale structural features and the composites can be used in applications such as catalysis for hydrogenation reactions and for analytical detection methods employing SERS.
Laser head for simultaneous optical pumping of several dye lasers. [with single flash lamp
NASA Technical Reports Server (NTRS)
Mumola, P. B.; Mcalexander, B. T. (Inventor)
1975-01-01
The invention is a laser head for simultaneous pumping several dye lasers with a single flash lamp. The laser head includes primarily a multi-elliptical cylinder cavity with a single flash lamp placed along the common focal axis of the cavity and with capillary tube dye cells placed along each of the other focal axes of the cavity. The inside surface of the cavity is polished. Hence, the single flash lamp supplies the energy to the several dye cells.
Low pressure arc discharge lamp apparatus with magnetic field generating means
Grossman, M.W.; George, W.A.; Maya, J.
1987-10-06
A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.
Suwancharoen, Duangjai; Sittiwicheanwong, Busara; Wiratsudakul, Anuwat
2016-09-01
Leptospirosis has been one of the worldwide zoonotic diseases caused by pathogenic Leptospira spp. Many molecular techniques have consecutively been developed to detect such pathogen including loop-mediated isothermal amplification method (LAMP). The objectives of this study were to evaluate the diagnostic accuracy of LAMP assay and real-time PCR using bacterial culture as the gold standard and to assess the agreement among these three tests using Cohen's kappa statistics. In total, 533 urine samples were collected from 266 beef and 267 dairy cattle reared in central region of Thailand. Sensitivity and specificity of LAMP were 96.8% (95% CI 81.5-99.8) and 97.0% (95% CI 94.9-98.2), respectively. The accuracy of LAMP (97.0%) was significantly higher than that of real-time PCR (91.9%) at 95% CI. With Cohen's kappa statistics, culture method and LAMP were substantially agreed with each other (77.4%), whereas real-time PCR only moderately agreed with culture (47.7%) and LAMP (45.3%), respectively. Consequently, LAMP was more effective than real-time PCR in detecting Leptospira spp. in the urine of cattle. Besides, LAMP had less cost and was simpler than real-time PCR. Thus, LAMP was an excellent alternative for routine surveillance of leptospirosis in cattle.
Max Tech and Beyond: High-Intensity Discharge Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholand, Michael
High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. Withmore » the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating conditions, and this necessitates additional power beyond that used by the lamp itself. HID lamps offer important advantages compared to other lighting technologies, making them well suited for certain applications. HID lamps can be very efficient, have long operating lives, are relatively temperature-insensitive and produce a large quantity of light from a small package. For these reasons, HID lamps are often used when high levels of illumination are required over large areas and where operating and maintenance costs must be kept to a minimum. Furthermore, if the installation has a significant mounting height, high-power HID lamps can offer superior optical performance luminaires, reducing the number of lamps required to illuminate a given area. The indoor environments best suited to HID lamps are those with high ceilings, such as those commonly found in industrial spaces, warehouses, large retail spaces, sports halls and large public areas. Research into efficacy improvements for HID lighting technologies has generally followed market demand for these lamps, which is in decline for MV and LPS, has reached a plateau for HPS and is growing for MH. Several manufacturers interviewed for this study indicated that although solid-state lighting was now receiving the bulk of their company's R&D investment, there are still strong HID lamp research programs, which concentrate on MH technologies, with some limited amount of investment in HPS for specific niche applications (e.g., agricultural greenhouses). LPS and MV lamps are no longer being researched or improved in terms of efficacy or other performance attributes, although some consider MH HID lamps to be the next-generation MV lamp. Thus, the efficacy values of commercially available MV, LPS and HPS lamps are not expected to increase in the next 5 to 10 years. MH lamps, and more specifically, ceramic MH lamps are continuing to improve in efficacy as well as light quality, manufacturability and lamp life. Within an HID lamp, the light-producing plasma must be heated to sufficiently high temperatures to achieve high efficiencies, without melting the electrodes or altering the operating conditions of the lamp. The research in ceramic MH has focused on the arc tube, the electrodes and the plasma, resulting in an innovation announced by Philips Lighting in 2009 called the 'unsaturated lamp.' The unsaturated lamp addresses a problem experienced by standard ceramic MH lamps where a pool of liquid salt develops in the arc tube while the lamp is operating. This pool of liquid salt limits the light characteristics of the lamp such as the efficacy and color quality, and reduces lamp lifetime. By making modifications to the arc tube, the pressure and the operating temperature, the unsaturated ceramic MH lamp resolves this issue by keeping all the halide salts in the gaseous phase, even while the lamp is dimming (down to 50%).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.
2014-05-20
Although lensed troffers are numerous, there are many other types of optical systems as well. This report looked at the performance of three linear (T8) LED lamps chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles) as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompaniedmore » by visual appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.« less
Eternal triangle: the interaction of light source, electrical control gear, and optics
NASA Astrophysics Data System (ADS)
S'heeren, Griet
1998-04-01
In this particular 'affair' the participants are less than human but have individual personalities they bring to their relationship with each other. High pressure metal halide lamps such as BriteArc lamps have the highest luminance and radiance of all continuously operating practical light source. Since these lamps have short arcs and are available in power ratings from about 30W to 30kW they have found applications with various optical systems. Besides the lamps, such systems include an electrical control device and an optical system. To fulfil the user's requirements for a specific application, it is not only important to choose the right lamp, but crucial to achieve a harmonious marriage between the light source, electrical control device and the optics. To run a high pressure discharge lamp an ignitor/ballast system is essential This stabilizes the lamp parameters. The chemical components inside the lamp determine the lamp voltage and the gear determines, via the current, the lamp power. These are directly related in the luminance and color temperature of the emitted light. Therefore lamp performance and effective life are dependent on the ignitor, control gear and lamp combination. Since the lamp emits radiation in all directions, collection of the light from a lamp can be improved by using reflectors to deliver the light into a lens system. Since lamps with short arc gaps approach a point source they appear ideal for optical system applications. The shape of the reflector and the focusing of the lamp determine which part of the light is collected out of the light-arc. In the case of an LCD projector, the final light output also depends on the transmission characteristics of the LCD panels. Their nonlinearity causes the color of the emitted light to be different from the lamp color. All these parameters have to be optimized to obtain the highest performance. This leads to the conclusion that a carefully matched combination of lamp, ignitor/ballast and optics should guarantee the best system performance. This paper sets out to provide some guidelines on attempting to achieve a harmonious relationship between the three partners in this particular eternal triangle.
Piera, Kim A; Aziz, Ammar; William, Timothy; Bell, David; González, Iveth J; Barber, Bridget E; Anstey, Nicholas M; Grigg, Matthew J
2017-01-13
Plasmodium knowlesi is the most common cause of malaria in Malaysia. However, microscopic diagnosis is inaccurate and rapid diagnostic tests (RDTs) are insufficiently sensitive. PCR is sensitive and specific but not feasible at a district level. Loop-mediated isothermal amplification (LAMP) shows potential with only basic requirements. A commercially available LAMP assay, the Eiken Loopamp™ MALARIA Pan Detection kit, is sensitive for Plasmodium falciparum and Plasmodium vivax, but has not previously been evaluated for P. knowlesi. This study aims to determine the sensitivity of this LAMP assay for detecting P. knowlesi infection. Study participants included 73 uncomplicated malaria patients with PCR species confirmation: 50 P. knowlesi, 20 P. falciparum and 3 P. vivax. Nineteen malaria-negative, non-endemic area controls were also included. The sensitivity of the Eiken Loopamp™ MALARIA Pan Detection kit (Pan LAMP) for detecting each Plasmodium species was evaluated. Sensitivity and specificity of the Eiken Loopamp™ MALARIA Pf Detection kit (Pf LAMP) for P. falciparum were also determined. The limit of detection for each LAMP assay was evaluated, with results compared to PCR. All P. knowlesi patients were also tested by CareStart™ (Pf/VOM) and OptiMAL-IT™ (Pan/Pf) RDTs. The sensitivity of the Pan LAMP assay was 100% for P. knowlesi (95% CI 92.9-100), P. falciparum (95% CI 83.2-100), and P. vivax (95% CI 29.2-100). The Pf LAMP was 100% sensitive and specific for P. falciparum detection, with all P. knowlesi samples having a negative reaction. LAMP sensitivity was superior to both RDTs, with only 10 and 28% of P. knowlesi samples testing positive to CareStart™ and OptiMAL-IT™, respectively. Limit of detection using the Pan LAMP for both P. knowlesi and P. vivax was 2 parasites/μL, comparable to PCR. For P. falciparum both the Pan LAMP and Pf LAMP demonstrated a limit of detection of 20 parasites/μL. The Eiken Loopamp™ MALARIA Pan Detection kit is sensitive for detection of P. knowlesi in low parasitaemia clinical infections, as well as P. falciparum and P. vivax. However, a P. knowlesi-specific field assay in a simpler format would assist correct species identification and initiation of optimal treatment for all malaria patients.
Hanaoka, Nozomu; Matsutani, Minenosuke; Satoh, Masaaki; Ogawa, Motohiko; Shirai, Mutsunori; Ando, Shuji
2017-01-24
We developed a novel loop-mediated isothermal amplification (LAMP) method to detect Rickettsia spp., including Rickettsia prowazekii and R. typhi. Species-specific LAMP primers were developed for orthologous genes conserved among Rickettsia spp. The selected modified primers could detect all the Rickettsia spp. tested. The LAMP method was successfully used to detect 100 DNA copies of Rickettsia spp. within approximately 60 min at 63℃. Therefore, this method may be an excellent tool for the early diagnosis of rickettsiosis in a laboratory or in the field.
Khan, M Nisa
2015-07-20
Light-emitting diode (LED) technologies are undergoing very fast developments to enable household lamp products with improved energy efficiency and lighting properties at lower cost. Although many LED replacement lamps are claimed to provide similar or better lighting quality at lower electrical wattage compared with general-purpose incumbent lamps, certain lighting characteristics important to human vision are neglected in this comparison, which include glare-free illumination and omnidirectional or sufficiently broad light distribution with adequate homogeneity. In this paper, we comprehensively investigate the thermal and lighting performance and trade-offs for several commercial LED replacement lamps for the most popular Edison incandescent bulb. We present simulations and analyses for thermal and optical performance trade-offs for various LED lamps at the chip and module granularity levels. In addition, we present a novel, glare-free, and production-friendly LED lamp design optimized to produce very desirable light distribution properties as demonstrated by our simulation results, some of which are verified by experiments.
NASA Astrophysics Data System (ADS)
Chvyreva, A.; Pancheshnyi, S.; Christen, T.; Pemen, A. J. M.
2018-03-01
Electrodeless streamer inception on an epoxy surface under AC voltage stress was investigated for different gas compositions and pressures, with a focus on the pressure region below 1 bar. For this purpose, we used a set-up with cylindrical electrodes embedded out-of-axis in a cylindrical epoxy rod. Experiments were performed in N2, SF6, ambient air, Ar and CO2. The discharge inception voltage was measured, from which the critical value K of the ionization integral was reconstructed assuming a non-disturbed Laplacian field distribution. We have validated that for electropositive gases Ar an N2 the generally assumed value of K = 10 is in good agreement with our measurements. For electronegative gases, however, the experimentally obtained values turned out to be considerably higher. We attribute this discrepancy mainly to the statistical time delay of the first electron; to increase the probability of discharge inception in a critical region, it was necessary to extend the critical area by means of applying an overvoltage to the system.
NASA Astrophysics Data System (ADS)
Yusuf, Gbadebo; Khalilzadeh-Rezaie, Farnood; Cleary, Justin W.; Oladeji, Isaiah O.; Suu, Koukou; Schoenfeld, Winston V.; Peale, Robert E.; Awodugba, Ayodeji O.
2015-04-01
This work investigated the characteristics of SnO2: F films grown by Streaming Process for Electrodeless Electrochemical Deposition (SPEED). Stannic chloride (SnCl4) and ammonium fluoride (NH4 F) was dissolved in a mixture of deionized water and organic solvents. The preheated substrate temperature was varied between 450 and 530° C. High quality SnO2: F films were grown at all the substrate temperatures studied. The typical film thickness was 250 nm. XRD shows that the grown films are polycrystalline SnO2 with a tetragonal crystal structure. The average optical transmission of the films was around 93% throughout the wavelength of 400 to 1000 nm. The lowest electrical resistivity achieved was 6 x 10-4 Ω cm. The Hall measurements showed that the film is an n-type semiconductor, with the highest carrier mobility of 8.3 cm2/V.s, and concentration of 1 x 1021 cm-3. The direct band gap was determined to be 4 eV from the transmittance spectrum.
Xenon lighting adjusted to plant requirements
NASA Technical Reports Server (NTRS)
Koefferlein, M.; Doehring, T.; Payer, Hans D.; Seidlitz, H. K.
1994-01-01
Xenon lamps are available as low and high power lamps with relatively high efficiency and a relatively long lifetime up to several thousand hours. Different construction types of short-arc and long-arc lamps permit a good adaptation to various applications in projection and illumination techniques without substantial changes of the spectral quality. Hence, the xenon lamp was the best choice for professional technical purposes where high power at simultaneously good spectral quality of the light was required. However, technical development does not stand still. Between the luminous efficacy of xenon lamps of 25-50 lm/W and the theoretical limit for 'white light' of 250 lm/W is still much room for improvement. The present development mainly favors other lamp types, like metal halide lamps and fluorescent lamps for commercial lighting purposes. The enclosed sections deal with some of the properties of xenon lamps relevant to plant illumination; particularly the spectral aspects, the temporal characteristics of the emission, and finally the economy of xenon lamps will be addressed. Due to radiation exceeding the natural global radiation in both the ultraviolet (UV) and the infrared (IR) regions, filter techniques have to be included into the discussion referring to the requirements of plant illumination. Most of the presented results were obtained by investigations in the GSF phytotron or in the closed Phytocell chambers of the University of Erlangen. As our experiences are restricted to area plant illumination rather than spot lights our discussion will concentrate on low pressure long-arc xenon lamps which are commonly used for such plant illuminations. As the spectral properties of short-arc lamps do not differ much from those of long-arc lamps most of our conclusions will be valid for high pressure xenon lamps too. These lamps often serve as light sources for small sun simulators and for monochromators which are used for action spectroscopy of plant responses.
Adams, Emily Rebecca; Schoone, Gerard; Versteeg, Inge; Gomez, Maria Adelaida; Diro, Ermias; Mori, Yasuyoshi; Perlee, Desiree; Downing, Tim; Saravia, Nancy; Assaye, Ashenafi; Hailu, Asrat; Albertini, Audrey; Ndung'u, Joseph Mathu; Schallig, Henk
2018-04-25
A novel Pan-Leishmania LAMP assay was developed for diagnosis of Cutaneous and Visceral Leishmaniasis (CL & VL) which can be used in near-patient settings. Primers were designed on the 18S rDNA and the conserved region of minicircle kDNA selected on the basis of high copy number. LAMP assays were evaluated for CL in a prospective cohort trial of 105 patients in South-West Colombia. Lesion swab samples from CL suspects were collected and tested using LAMP and compared to a composite reference of microscopy AND/OR culture to calculate diagnostic accuracy. LAMP assays were tested on 50 VL suspected patients from Ethiopia, including whole blood, peripheral blood mononuclear cells, and buffy coat. Diagnostic accuracy was calculated against a reference standard of microscopy of splenic or bone marrow aspirates. To calculate analytical specificity 100 clinical samples and isolates with fever causing pathogens including malaria, arboviruses and bacterial infections were tested. The LAMP assay had a sensitivity of 95% (95% CI: 87.2% - 98.5 %) and a specificity of 86% (95% CI: 67.3% -95.9 %) for the diagnosis of CL. On VL suspects the sensitivity was 92% (95% CI: 74.9 - 99.1%) and specificity of 100% (95% CI: 85.8-100%) in whole blood. For CL, LAMP is a sensitive tool for diagnosis and requires less equipment, time and expertise than alternative CL diagnostics. For VL, LAMP is sensitive using a minimally invasive sample as compared to the gold standard. The analytical specificity was 100%. Copyright © 2018 Adams et al.
Enhancing space transportation: The NASA program to develop electric propulsion
NASA Technical Reports Server (NTRS)
Bennett, Gary L.; Watkins, Marcus A.; Byers, David C.; Barnett, John W.
1990-01-01
The NASA Office of Aeronautics, Exploration, and Technology (OAET) supports a research and technology (R and T) program in electric propulsion to provide the basis for increased performance and life of electric thruster systems which can have a major impact on space system performance, including orbital transfer, stationkeeping, and planetary exploration. The program is oriented toward providing high-performance options that will be applicable to a broad range of near-term and far-term missions and vehicles. The program, which is being conducted through the Jet Propulsion Laboratory (JPL) and Lewis Research Center (LeRC) includes research on resistojet, arcjets, ion engines, magnetoplasmadynamic (MPD) thrusters, and electrodeless thrusters. Planning is also under way for nuclear electric propulsion (NEP) as part of the Space Exploration Initiative (SEI).
CALiPER Report 20.2: Dimming, Flicker, and Power Quality Characteristics of LED PAR38 Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2014-03-31
This report focuses on the flicker and power quality performance of the Series 20 lamps at full output and various dimmed levels. All of the Series 20 PAR38 lamps that manufacturers claimed to be dimmable (including all halogen lamps) were evaluated individually (one lamp at a time) both on a switch and under the control of a phase-cut dimmer designed for use with "all classes of bulbs." Measurements of luminous flux, flicker, and power quality were taken at 10 target dimmed settings and compared with operation on a switch. Because only a single unit of each product was evaluated onmore » a single dimmer that may or may not have been recommended by its manufacturer, this report focuses on the performance of the products relative to each other, rather than the best-case performance of each lamp or variation in performance delivered from each lamp. Despite these limitations, the results suggest that LED performance is improving, and performance trends are beginning to emerge, perhaps due in part to the identification of preferred LED driver strategies for lamp products.« less
Filter for isotopic alteration of mercury vapor
Grossman, M.W.; George, W.A.
1989-06-13
A filter is described for enriching the [sup 196]Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The [sup 196]Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is, less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter. 9 figs.
Filter for isotopic alteration of mercury vapor
Grossman, Mark W.; George, William A.
1989-01-01
A filter for enriching the .sup.196 Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The .sup.196 Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter.
LAMP-2 mediates oxidative stress-dependent cell death in Zn2+-treated lung epithelium cells.
Qin, Xia; Zhang, Jun; Wang, Bin; Xu, Ge; Zou, Zhen
2017-06-17
Zinc is an essential element for the biological system. However, excessive exogenous Zn 2+ would disrupt cellular Zn 2+ homeostasis and cause toxicity. In particular, Zinc salts or ZnO nanoparticles exposure could induce respiratory injury. Although previous studies have indicated that organelle damage (including mitochondria or lysosomes) and reactive oxygen species (ROS) production are involved in Zn 2+ -induced toxicity, the interplay between mitochondria/lysosomes damage and ROS production is obscure. Herein, we demonstrated that Zn 2+ could induce deglycosylation of lysosome-associated membrane protein 1 and 2 (LAMP-1 and LAMP-2), which primarily locate in late endosomes/lysosomes, in A549 lung epithelium cells. Intriguingly, LAMP-2 knockdown further aggravated Zn 2+ -mediated ROS production and cell death, indicating LAMP-2 (not LAMP-1) was involved in Zn 2+ -induced toxicity. Our results provide a new insight that LAMP-2 contributes to the ROS clearance and cell death induced by Zn 2+ treatment, which would help us to get a better understanding of Zn 2+ -induced toxicity in respiratory system. Copyright © 2017 Elsevier Inc. All rights reserved.
Numerical study on xenon positive column discharges of mercury-free lamp
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ouyang, Jiting; He, Feng; Miao, Jinsong
2007-02-15
In this paper, the numerical study has been performed on the xenon positive column discharges of mercury-free fluorescent lamp. The plasma discharge characteristics are analyzed by numerical simulation based on two-dimensional fluid model. The effects of cell geometry, such as the dielectric layer, the electrode width, the electrode gap, and the cell height, and the filling gas including the pressure and the xenon percentage are investigated in terms of discharge current and discharge efficiency. The results show that a long transient positive column will form in the xenon lamp when applying ac sinusoidal power and the lamp can operate inmore » a large range of voltage and frequency. The front dielectric layer of the cell plays an important role in the xenon lamp while the back layer has little effect. The ratio of electrode gap to cell height should be large to achieve a long positive column xenon lamp and higher efficiency. Increase of pressure or xenon concentration results in an increase of discharge efficiency and voltage. The discussions will be helpful for the design of commercial xenon lamp cells.« less
CALiPER Report 21.2. Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-05-01
Although lensed troffers are numerous, there are many other types of optical systems as well. This report looks at the performance of three linear (T8) LED lamps—chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles)—as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompanied by visualmore » appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.« less
Lamp pumped Nd:YAG laser. Space-qualifiable Nd:YAG laser for optical communications
NASA Technical Reports Server (NTRS)
Ward, K. B.
1973-01-01
Results are given of a program concerned with the design, fabrication, and evaluation of alkali pump lamps for eventual use in a space qualified Nd:YAG laser system. The study included evaluation of 2mm through 6mm bore devices. Primary emphasis was placed upon the optimization of the 4mm bore lamp and later on the 6mm bore lamp. As part of this effort, reference was made to the Sylvania work concerned with the theoretical modeling of the Nd:YAG laser. With the knowledge gained, a projection of laser performance was made based upon realistic lamp parameters which should easily be achieved during following developmental efforts. Measurements were made on the lamp performance both in and out of the cavity configuration. One significant observation was that for a constant vapor pressure device, the spectral and fluorescent output did not vary for vacuum or argon environment. Therefore, the laser can be operated in an inert environment (eg. argon) with no degradation in output. Laser output of 3.26 watts at 430 watts input was obtained for an optimized 4mm bore lamp.
Atmospheric pressure helium afterglow discharge detector for gas chromatography
Rice, G.; D'Silva, A.P.; Fassel, V.A.
1985-04-05
An apparatus for providing a simple, low-frequency, electrodeless discharge system for atmospheric pressure afterglow generation. A single quartz tube through which a gas mixture is passed is extended beyond a concentric electrode positioned thereabout. A grounding rod is placed directly above the tube outlet to permit optical viewing of the discharge between the electrodes.
Atmospheric pressure helium afterglow discharge detector for gas chromatography
Rice, Gary; D'Silva, Arthur P.; Fassel, Velmer A.
1986-05-06
An apparatus for providing a simple, low-frequency electrodeless discharge system for atmospheric pressure afterglow generation. A single quartz tube through which a gas mixture is passed is extended beyond a concentric electrode positioned thereabout. A grounding rod is placed directly above the tube outlet to permit optical viewing of the discharge between the electrodes.
Monitoring and Morphologic Classification of Pediatric Cataract Using Slit-Lamp-Adapted Photography.
Long, Erping; Lin, Zhuoling; Chen, Jingjing; Liu, Zhenzhen; Cao, Qianzhong; Lin, Haotian; Chen, Weirong; Liu, Yizhi
2017-11-01
To investigate the feasibility of pediatric cataract monitoring and morphologic classification using slit lamp-adapted anterior segmental photography in a large cohort that included uncooperative children. Patients registered in the Childhood Cataract Program of the Chinese Ministry of Health were prospectively selected. Eligible patients underwent slit-lamp adapted anterior segmental photography to record and monitor the morphology of their cataractous lenses. A set of assistance techniques for slit lamp-adapted photography was developed to instruct the parents of uncooperative children how to help maintain the child's head position and keep the eyes open after sleep aid administration. Briefly, slit lamp-adapted photography was completed for all 438 children, including 260 (59.4%) uncooperative children with our assistance techniques. All 746 images of 438 patients successfully confirmed the diagnoses and classifications. Considering the lesion location, pediatric cataract morphologies could be objectively classified into the seven following types: total; nuclear; polar, including two subtypes (anterior and posterior); lamellar; nuclear combined with cortical, including three subtypes (coral-like, dust-like, and blue-dot); cortical; and Y suture. The top three types of unilateral cataracts were polar (55, 42.3%), total (42, 32.3%), and nuclear (23, 17.7%); and the top three types of bilateral cataracts were nuclear (110, 35.8%), total (102, 33.2%), and lamellar (34, 11.1%). Slit lamp-adapted anterior segmental photography is applicable for monitoring and classifying the morphologies of pediatric cataracts and is even safe and feasible for uncooperative children with assistance techniques and sleep aid administration. This study proposes a novel strategy for the preoperative evaluation and evidence-based management of pediatric ophthalmology (Clinical Trials.gov, NCT02748031).
Rothaug, Michelle; Stroobants, Stijn; Schweizer, Michaela; Peters, Judith; Zunke, Friederike; Allerding, Mirka; D'Hooge, Rudi; Saftig, Paul; Blanz, Judith
2015-01-31
The Lysosomal Associated Membrane Protein type-2 (LAMP-2) is an abundant lysosomal membrane protein with an important role in immunity, macroautophagy (MA) and chaperone-mediated autophagy (CMA). Mutations within the Lamp2 gene cause Danon disease, an X-linked lysosomal storage disorder characterized by (cardio)myopathy and intellectual dysfunction. The pathological hallmark of this disease is an accumulation of glycogen and autophagic vacuoles in cardiac and skeletal muscle that, along with the myopathy, is also present in LAMP-2-deficient mice. Intellectual dysfunction observed in the human disease suggests a pivotal role of LAMP-2 within brain. LAMP-2A, one specific LAMP-2 isoform, was proposed to be important for the lysosomal degradation of selective proteins involved in neurodegenerative diseases such as Huntington's and Parkinson's disease. To elucidate the neuronal function of LAMP-2 we analyzed knockout mice for neuropathological changes, MA and steady-state levels of CMA substrates. The absence of LAMP-2 in murine brain led to inflammation and abnormal behavior, including motor deficits and impaired learning. The latter abnormality points to hippocampal dysfunction caused by altered lysosomal activity, distinct accumulation of p62-positive aggregates, autophagic vacuoles and lipid storage within hippocampal neurons and their presynaptic terminals. The absence of LAMP-2 did not apparently affect MA or steady-state levels of selected CMA substrates in brain or neuroblastoma cells under physiological and prolonged starvation conditions. Our data contribute to the understanding of intellectual dysfunction observed in Danon disease patients and highlight the role of LAMP-2 within the central nervous system, particularly the hippocampus.
The design of optical module of LED street lamp with non-axial symmetrical reflector
NASA Astrophysics Data System (ADS)
Lu, Ming-Jun; Chen, Chi-An; Chen, Yi-Yung; Whang, Allen Jong-Woei
2010-05-01
In recently, many research focus on the LED applications for environmental protection so a number of LED street lamps are presented. Although LED has many advantages for environmental protection, its special optical characteristics, such as intensity distribution, always limit the advantages in many applications. Therefore, we always need to do the secondary optical design for LED street lamp to replace the traditional optical designs that are designed for high-pressure sodium lamps and mercury lamps. According to the situation, we design an optical module of LED street lamp with LEDs and secondary optical design. First, the LEDs are placed on freeform reflector for the specific illuminated conditions. We design the optical module of street lamp with the two conditions that include the uniformity and the ratio of length to width in the illuminated area and without any light pollution. According to the simulation with the designed optical module, the uniformity in the illuminated area is about 0.6 that is better than the general condition, 0.3, and the ratio of length to width in the illuminated area is 3:1 in which the length is 30 meters and the width is 10 meters. Therefore, the design could let LED street lamp fits the two conditions, uniformity and ratio in the illuminated area.
Wong, Y-P; Othman, S; Lau, Y-L; Radu, S; Chee, H-Y
2018-03-01
Loop-mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. ( Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro-organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro-organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real-time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro-organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease. © 2017 The Society for Applied Microbiology.
Imai, Kazuo; Tarumoto, Norihito; Misawa, Kazuhisa; Runtuwene, Lucky Ronald; Sakai, Jun; Hayashida, Kyoko; Eshita, Yuki; Maeda, Ryuichiro; Tuda, Josef; Murakami, Takashi; Maesaki, Shigefumi; Suzuki, Yutaka; Yamagishi, Junya; Maeda, Takuya
2017-09-13
A simple and accurate molecular diagnostic method for malaria is urgently needed due to the limitations of conventional microscopic examination. In this study, we demonstrate a new diagnostic procedure for human malaria using loop mediated isothermal amplification (LAMP) and the MinION™ nanopore sequencer. We generated specific LAMP primers targeting the 18S-rRNA gene of all five human Plasmodium species including two P. ovale subspecies (P. falciparum, P. vivax, P. ovale wallikeri, P. ovale curtisi, P. knowlesi and P. malariae) and examined human blood samples collected from 63 malaria patients in Indonesia. Additionally, we performed amplicon sequencing of our LAMP products using MinION™ nanopore sequencer to identify each Plasmodium species. Our LAMP method allowed amplification of all targeted 18S-rRNA genes of the reference plasmids with detection limits of 10-100 copies per reaction. Among the 63 clinical samples, 54 and 55 samples were positive by nested PCR and our LAMP method, respectively. Identification of the Plasmodium species by LAMP amplicon sequencing analysis using the MinION™ was consistent with the reference plasmid sequences and the results of nested PCR. Our diagnostic method combined with LAMP and MinION™ could become a simple and accurate tool for the identification of human Plasmodium species, even in resource-limited situations.
CALiPER Report 21.3: Cost-Effectiveness of Linear (T8) LED Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.
2014-05-27
Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15more » minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.« less
CALiPER Report 21.3. Cost Effectiveness of Linear (T8) LED Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-05-01
Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15more » minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.« less
Effect of lamp type and temperature on development, carbon partitioning and yield of soybean
NASA Astrophysics Data System (ADS)
Dougher, T. A. O.; Bugbee, B.
1997-01-01
Soybeans grown in controlled environments are commonly taller than field-grown plants. In controlled environments, including liquid hydroponics, height of the dwarf cultivar ``Hoyt'' was reduced from 46 to 33 cm when plants were grown under metal halide lamps compared to high pressure sodium lamps at the same photosynthetic photon flux. Metal halide lamps reduced total biomass 14% but did not significantly reduce seed yield. Neither increasing temperature nor altering the difference between day/night temperature affected plant height. Increasing temperature from 21 to 27 degC increased yield 32%. High temperature significantly increased carbon partitioning to stems and increased harvest index.
Light shield and cooling apparatus. [high intensity ultraviolet lamp
NASA Technical Reports Server (NTRS)
Meador, T. G., Jr. (Inventor)
1974-01-01
A light shield and cooling apparatus was developed for a high intensity ultraviolet lamp including water and high pressure air for cooling and additional apparatus for shielding the light and suppressing the high pressure air noise.
Electric lamp, base for use therewith and method of assembling same
Hough, Harold L.; English, George J.; Chakrabarti, Kirti B.
1989-02-14
An electric lamp including a reflector, at least one conductive ferrule located within a surface of the reflector and a lead-in conductor electrically connected to the ferrule and extending within the reflector. The lamp includes a base having an insulative (e.g., ceramic) cap located substantially about the ferrule, barrier means (e.g., ceramic fiber) located within the cap to define an open chamber substantially about the ferrule, an electrical conductor (e.g., wire) extending within the cap and electrically connected (e.g., silver soldered) to the ferrule, and sealing means (e.g., high temperature cement) located within the cap to provide a seal therefore. The barrier means serves to separate the sealing means from the open chamber about the ferrule such that the heat generated by the ferrule can be vented through spaced apertures located within the cap's side wall. A method of assembling a base on an electric lamp is also provided.
Maan, S; Maan, N S; Batra, K; Kumar, A; Gupta, A; Rao, Panduranga P; Hemadri, Divakar; Reddy, Yella Narasimha; Guimera, M; Belaganahalli, M N; Mertens, P P C
2016-08-01
Bluetongue virus (BTV) infects all ruminants, including cattle, goats and camelids, causing bluetongue disease (BT) that is often severe in naïve deer and sheep. Reverse-transcription-loop-mediated-isothermal-amplification (RT-LAMP) assays were developed to detect eastern or western topotype of BTV strains circulating in India. Each assay uses four primers recognizing six distinct sequences of BTV genome-segment 1 (Seg-1). The eastern (e)RT-LAMP and western (w)RT-LAMP assay detected BTV RNA in all positive isolates that were tested (n=52, including Indian BTV-1, -2, -3, -5, -9, -10, -16, -21 -23, and -24 strains) with high specificity and efficiency. The analytical sensitivity of the RT-LAMP assays is comparable to real-time RT-PCR, but higher than conventional RT-PCR. The accelerated eRT-LAMP and wRT-LAMP assays generated detectable levels of amplified DNA, down to 0.216 fg of BTV RNA template or 108 fg of BTV RNA template within 60-90min respectively. The assays gave negative results with RNA from foot-and-mouth-disease virus (FMDV), peste des petits ruminants virus (PPRV), or DNA from Capripox viruses and Orf virus (n=10), all of which can cause clinical signs similar to BT. Both RT-LAMP assays did not show any cross-reaction among themselves. The assays are rapid, easy to perform, could be adapted as a 'penside' test making them suitable for 'front-line' diagnosis, helping to identify and contain field outbreaks of BTV. Copyright © 2016 Elsevier B.V. All rights reserved.
49 CFR Appendix A to Part 221 - Procedures for Approval of Rear End Marking Devices
Code of Federal Regulations, 2011 CFR
2011-10-01
... description of the device including the type, luminance description, size of lens, manufacturer and catalog number, lamp manufacturer, lamp type and model number, and any auxiliary optics used. (2) A certification...
49 CFR Appendix A to Part 221 - Procedures for Approval of Rear End Marking Devices
Code of Federal Regulations, 2010 CFR
2010-10-01
... description of the device including the type, luminance description, size of lens, manufacturer and catalog number, lamp manufacturer, lamp type and model number, and any auxiliary optics used. (2) A certification...
Max Tech and Beyond: Fluorescent Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholand, Michael
2012-04-01
Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicatedmore » that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2) Enhanced fill gas - adjusting proportions of argon, krypton, neon and xenon to optimize performance, while also minimizing the mercury dose; (3) Improved cathode coatings to enhance electron emissivity and extend lamp life; and (4) UV-reflective glass coatings deposited between the layer of phosphor and the glass tube, to reflect any UV light back into the phosphor layer for down-conversion.« less
LED lamp power management system and method
Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.
2013-03-19
An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.
Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan
2013-11-01
The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg(-1) GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25.
NASA Technical Reports Server (NTRS)
Snow, W. L.; Morris, O. A.
1984-01-01
Methods for increasing the radiant in light sheets used for vapor screen set-ups were investigated. Both high-pressure mercury arc lamps and lasers were considered. Pulsed operation of the air-cooled 1-kW lamps increased the light output but decreased reliability. An ellipsoidal mirror improved the output of the air-cooled lamps by concentrating the light but increased the complexity of the housing. Water-cooled-4-kW lamps coupled with high-aperture Fresnel lenses provided reasonable improvements over the air-cooled lamps. Fanned laser beams measurements of scattered light versus dew point made in conjunction with successful attempts to control the fluid injection. A number of smoke generators are described and test results comparing smoke and vapor screens are shown. Finally, one test included a periscope system to relay the image to a camera outside the flow.
Lamp of adjustable spectrum for photographic usage
NASA Astrophysics Data System (ADS)
Mazikowski, Adam; Feldzensztajn, Mateusz
2017-08-01
Photography is a unique rapidly growing interdisciplinary field encompassing aspects of science, art and technology. Expectations of photographers are steadily increasing with the development of technology. One of the areas playing a crucial role in photography is lighting. Consequently, several types of light sources for photographic use have been developed. The ongoing research in this field concentrates on lamps with tunable CCT (Correlated Color Temperature). In this paper, we present a lamp, which emission spectrum can be tailored without affecting the output luminous ux. Intended for photographic uses, the lamp is based on an integrating sphere and a selection of LEDs. As the LED drivers, DC-DC converters controlled by a Raspberry PI were applied. Design process, including the selection of LED wavelengths, is presented. Output characteristics of the lamp were measured using the setup containing the spectrometer. The results of these experiments show good agreement with the spectrum set on the microcomputer.
Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25
Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan
2013-01-01
The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg−1 GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25. PMID:24804053
Sun, Wen-Wen; Sun, Qin; Yan, Li-Ping; Zhang, Qing
2017-08-22
Here, we evaluated the potential activity of rapid Mycobacterium tuberculosis detection with loop-mediated isothermal amplification (LAMP), for the early diagnosis of tuberculous meningitis (TBM). Patients with suspected TBM from January 2014 to December 2015 were reviewed retrospectively. The cerebrospinalfluid(CSF) was collected. Acid-fast bacillus (AFB) staining, MGIT 960 culture, real-time fluorescent quantitative polymerase chain reaction (RTFQ PCR) and LAMP were performed. A total of 200 patients were included in the study. Of which, 172 of them were diagnosed with TBM (86.00%). The sensitivities of AFB staining, MGIT 960 culture, LAMP and RTFQ PCR for TBM diagnosis were 2.91% (5/172), 12.79% (22/172), 43.02% (74/172), and 34.30% (59/172), respectively. The sensitivity of LAMP for TBM was significantly higher than those of AFB staining and MGIT960 culture ( χ2 = 75.11, P < 0.001; χ2 = 43.88, P = 0.002). LAMP's sensitivity was however comparable to RTFQ PCR assay ( χ2 = 2.08, P = 0.130). The specificity, positive predictive value and negative predictive value of LAMP in the diagnosis of TBM were 92.86% (26/28), 97.37% (74/76) and 20.97 % (26/124), respectively. The overall consistency between LAMP and RTFQ PCR in the diagnosis of TBM was 88.5% (177/200), with Kappa value of 0.870. The consistency between LAMP and MGIT960 culture was 71% (142/200), with Kappa value of 0.730. Among all the methods, LAMP had high sensitivity, specificity and positive predictive value, showing high consistency with MGIT960 culture and RTFQ PCR.
Modeling Ultraviolet (UV) Light Emitting Diode (LED) Energy Propagation in Reactor Vessels
2014-03-27
21 Table 4: UV Mercury Lamps , UV LED Bulbs, and Visible LED Bulb Advantages and Disadvantages...over low pressure mercury lamps include smaller size, minimal start up time, and no hazardous material. Projections show UV LEDs will follow similar
Miniature Incandescent Lamps as Fiber-Optic Light Sources
NASA Technical Reports Server (NTRS)
Tuma, Margaret; Collura, Joe; Helvajian, Henry; Pocha, Michael; Meyer, Glenn; McConaghy, Charles F.; Olsen, Barry L.
2008-01-01
Miniature incandescent lamps of a special type have been invented to satisfy a need for compact, rapid-response, rugged, broadband, power-efficient, fiber-optic-coupled light sources for diverse purposes that could include calibrating spectrometers, interrogating optical sensors, spot illumination, and spot heating.
Zhang, Liding; Wei, Qiujiang; Han, Qinqin; Chen, Qiang; Tai, Wenlin; Zhang, Jinyang; Song, Yuzhu; Xia, Xueshan
2018-01-01
Shigella is an important human food-borne zoonosis bacterial pathogen, and can cause clinically severe diarrhea. There is an urgent need to develop a specific, sensitive, and rapid methodology for detection of this pathogen. In this study, loop-mediated isothermal amplification (LAMP) combined with magnetic immunocapture assay (IC-LAMP) was first developed for the detection of Shigella in pure culture, artificial milk, and clinical stool samples. This method exhibited a detection limit of 8.7 CFU/mL. Compared with polymerase chain reaction, IC-LAMP is sensitive, specific, and reliable for monitoring Shigella. Additionally, IC-LAMP is more convenient, efficient, and rapid than ordinary LAMP, as it is more efficiently enriches pathogen cells without extraction of genomic DNA. Under isothermal conditions, the amplification curves and the green fluorescence were detected within 30 min in the presence of genomic DNA template. The overall analysis time was approximately 1 h, including the enrichment and lysis of the bacterial cells, a significantly short detection time. Therefore, the IC-LAMP methodology described here is potentially useful for the efficient detection of Shigella in various samples. PMID:29467730
D'Agostini, F; Caimo, A; De Filippi, S; De Flora, S
1999-07-01
Previous studies have shown that the light emitted by halogen tungsten lamps contains UV radiation in the UV-A, UV-B and UV-C regions, induces mutations and irreparable DNA damage in bacteria, enhances the frequency of micronuclei in cultured human lymphocytes and is potently carcinogenic to the skin of hairless mice. The present study showed that the light emitted by an uncovered, traditional halogen lamp induces a significant, dose-related and time-related increase not only in micronuclei but also in chromosome-type aberrations, such as breaks, and even more in chromatid-type aberrations, such as isochromatid breaks, exchanges and isochromatid/chromatid interchanges, all including gaps or not, in cultured human lymphocytes. All these genotoxic effects were completely prevented by shielding the same lamp with a silica glass cover, blocking UV radiation. A new model of halogen lamp, having the quartz bulb treated in order to reduce the output of UV radiation, was considerably less genotoxic than the uncovered halogen lamp, yet induction of chromosomal alterations was observed at high illuminance levels.
Leone, Dario Armando; Peschel, Andrea; Brown, Markus; Schachner, Helga; Ball, Miriam J; Gyuraszova, Marianna; Salzer-Muhar, Ulrike; Fukuda, Minoru; Vizzardelli, Caterina; Bohle, Barbara; Rees, Andrew J; Kain, Renate
2017-07-15
The lysosome-associated membrane protein (LAMP) family includes the dendritic cell endocytic receptors DC-LAMP and CD68, as well as LAMP-1 and LAMP-2. In this study we identify LAMP-1 (CD107a) and LAMP-2 (CD107b) on the surface of human monocyte-derived dendritic cells (MoDC) and show only LAMP-2 is internalized after ligation by specific Abs, including H4B4, and traffics rapidly but transiently to the MHC class II loading compartment, as does Ag conjugated to H4B4. However, pulsing MoDC with conjugates of primary (keyhole limpet hemocyanin; KLH) and recall (Bet v 1) Ags (H4B4*KLH and H4B4*Bet v 1) induced significantly less CD4 cell proliferation than pulsing with native Ag or Ag conjugated to control mAb (ISO*KLH and ISO*Bet v 1). In H4B4*KLH-pulsed MoDC, the duration of KLH residence in MHC class II loading compartments was significantly reduced, as were surface HLA-DR and DR-bound KLH-derived peptides. Paradoxically, MoDC pulsed with H4B4*KLH, but not the other KLH preparations, induced robust proliferation of CD4 cells separated from them by a transwell membrane, indicating factors in the supernatant were responsible. Furthermore, extracellular vesicles from supernatants of H4B4*KLH-pulsed MoDC contained significantly more HLA-DR and KLH than those purified from control MoDC, and KLH was concentrated specifically in exosomes that were a uniquely effective source of Ag in standard T cell proliferation assays. In summary, we identify LAMP-2 as an endocytic receptor on human MoDC that routes cargo into unusual Ag processing pathways, which reduces surface expression of Ag-derived peptides while selectively enriching Ag within immunogenic exosomes. This novel pathway has implications for the initiation of immune responses both locally and at distant sites. Copyright © 2017 by The American Association of Immunologists, Inc.
Pimenta, A F; Reinoso, B S; Levitt, P
1996-11-11
The limbic system-associated membrane protein (LAMP) is a 64-68 kDa neuronal surface glycoprotein expressed in cortical and subcortical regions of the limbic system of the adult and developing rat central nervous system (CNS). LAMP is a member of the immunoglobulin superfamily of cell adhesion molecules with three Ig domains and is highly conserved between rat and human. In this study, the temporal and spatial pattern of lamp gene expression during fetal rat development was analyzed by using Northern blot analysis and in situ hybridization. In Northern blot analysis, two lamp mRNA transcripts, 1.6 kb and 8.0 kb, identical in size to those present in the adult rat nervous system, were detected in developing neural tissue. In situ hybridization analysis showed close correlation, though not identity, between the expression of lamp mRNAs and the distribution of LAMP in limbic regions of the developing rat CNS, indicative of a more complex regulation of gene expression than was previously thought to be the case. The expression of lamp mRNAs is first detected on about embryonic day (E) 13. The hybridization signal is not seen in the proliferative ventricular zone at any level of the neuraxis, indicating that lamp is expressed in postmitotic neurons. In the cerebral cortex, lamp mRNAs are expressed in limbic cortical regions, such as the perirhinal cortex, prefrontal cortex, and cingulate cortex. In the hippocampus, the hybridization signal is observed in Ammon's horn by E18. The neostriatum, amygdaloid complex, and most hypothalamic areas express lamp mRNAs from early stages (E13-E14) in a pattern consistent with the onset of neurogenesis. The emerging patterns of lamp expression at the outset are similar to those seen in adult hypothalamus and dorsal thalamus. Although the hybridization signal is observed in some nonlimbic areas, including midbrain and hindbrain structures, intense labeling is evident in more classic limbic regions. The high levels of expression of lamp in limbic regions, beginning in early developmental stages, combined with the results of previous functional in vitro and in vivo studies, support a role for LAMP as a recognition molecule involved in the formation of limbic connections.
Fogel, Joshua; Krausz, Faye
2013-05-01
Ultraviolet radiation exposure through natural sunlight or tanning lamps is a risk factor for skin cancer. As the media can influence behavior, we studied whether watching reality television (TV) beauty shows is associated with tanning lamp use or outdoor tanning. College students (n = 576) were surveyed on their reality TV beauty show watching, their use of tanning lamps, and outdoor tanning behavior. We asked media attitude questions about connectivity with reality TV shows and Internet use of Facebook to discuss reality TV shows. Those who did versus did not watch reality TV beauty shows used tanning lamps (12.9% vs 3.7%, P < .001) and tanned outdoors (43.3% vs 28.7%, P < .001) at significantly greater percentages. Significant predictors of tanning lamp use included watching reality TV beauty shows (odds ratio [OR] 2.58, 95% confidence interval [CI] 1.11-6.00), increasing age (OR 1.17, 95% CI 1.04-1.32), and female sex (OR 10.16, 95% CI 3.29-31.41). Significant predictors of outdoor tanning included watching reality TV beauty shows (OR 2.11, 95% CI 1.33-3.34). The specific names of the reality TV beauty shows watched were not obtained and therefore we cannot determine if particular shows were more or less associated with this behavior. Watching reality TV beauty shows is associated with both tanning lamp use and outdoor tanning. Dermatologists should consider discussing the potential harmful aspects of tanning beds and outdoor tanning, especially with their patients who watch reality TV beauty shows. Copyright © 2012 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
Chamania, S; Chouhan, R; Awasthi, A; Bendell, R; Marsden, N; Gibson, J; Whitaker, I S; Potokar, T S
2015-05-01
Globally, 300,000 deaths are estimated to occur annually and the incidence is far greater as a large majority of burns are small and go unreported. Ninety-five percent of the global burden of burns is found in low- and middle-income countries; however, there is relatively little in the literature regarding effective primary prevention in these areas. Flame is the most common cause of burn in Madhya Pradesh, the central state of India. The most common demographic among the burn unit inpatient of Choithram hospital Indore, is young women from 21 to 40 years of age, whose burns are primarily caused by kerosene lamps. A non electrical source of illumination is essential for every household in rural areas due to the infrequent and poor power supply. At the baseline, 23 kerosene lamp burns were reported by villagers in the past 5 years among the study population of this pilot project. A pilot project to investigate the strategies for reducing the incidence of domestic burns in rural villages around the city of Indore was performed, by replacing kerosene lamps with safer and more sustainable alternatives, including solar-powered and light-emitting diode (LED) lamps. A total of 1042 households were randomly chosen from 18 villages within the Malwa region of Madhya Pradesh (population of 28,825) to receive the alternative light source (670 LED and 372 solar lamps). We investigated the efficacy of this strategy of reducing the incidence of burns, measured the social acceptance by villagers, and quantified the cost implications and availability of LED lamps in rural communities with a high incidence of burns. Replacing kerosene lamps with LED and solar alternatives was deemed socially acceptable by 99.34% of the participants and reduced the cost of lighting for impoverished rural villagers by 85% over 1 year. We successfully demonstrated a significant decrease in the use of kerosene lamps (p<0.01). More evidence is required to investigate the efficacy of this strategy in reducing burns. This pilot study highlights the viability of the approach of replacing kerosene lamps as an effective primary prevention strategy for reducing burns in rural areas. However, barriers remain to the wider adoption of these lamps, including accessibility and availability for the populations of rural India. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Metal halide arc discharge lamp having short arc length
NASA Technical Reports Server (NTRS)
Muzeroll, Martin E. (Inventor)
1994-01-01
A metal halide arc discharge lamp includes a sealed light-transmissive outer jacket, a light-transmissive shroud located within the outer jacket and an arc tube assembly located within the shroud. The arc tube assembly includes an arc tube, electrodes mounted within the arc tube and a fill material for supporting an arc discharge. The electrodes have a spacing such that an electric field in a range of about 60 to 95 volts per centimeter is established between the electrodes. The diameter of the arc tube and the spacing of the electrodes are selected to provide an arc having an arc diameter to arc length ratio in a range of about 1.6 to 1.8. The fill material includes mercury, sodium iodide, scandium tri-iodide and a rare gas, and may include lithium iodide. The lamp exhibits a high color rendering index, high lumen output and high color temperature.
NASA Astrophysics Data System (ADS)
Galadí-Enríquez, D.
2018-02-01
Correlated color temperature (CCT) is a semi-quantitative system that roughly describes the spectra of lamps. This parameter gives the temperature (measured in kelvins) of the black body that would show the hue more similar to that of the light emitted by the lamp. Modern lamps for indoor and outdoor lighting display many spectral energy distributions, most of them extremely different to those of black bodies, what makes CCT to be far from a perfect descriptor from the physical point of view. The spectral index system presented in this work provides an accurate, objective, quantitative procedure to characterize the spectral properties of lamps, with just a few numbers. The system is an adaptation to lighting technology of the classical procedures of multi-band astronomical photometry with wide and intermediate-band filters. We describe the basic concepts and we apply the system to a representative set of lamps of many kinds. The results lead to interesting, sometimes surprising conclusions. The spectral index system is extremely easy to implement from the spectral data that are routinely measured at laboratories. Thus, including this kind of computations in the standard protocols for the certification of lamps will be really straightforward, and will enrich the technical description of lighting devices.
Longcore, Travis; Aldern, Hannah L.; Eggers, John F.; Flores, Steve; Franco, Lesly; Hirshfield-Yamanishi, Eric; Petrinec, Laina N.; Yan, Wilson A.; Barroso, André M.
2015-01-01
Artificial lighting allows humans to be active at night, but has many unintended consequences, including interference with ecological processes, disruption of circadian rhythms and increased exposure to insect vectors of diseases. Although ultraviolet and blue light are usually most attractive to arthropods, degree of attraction varies among orders. With a focus on future indoor lighting applications, we manipulated the spectrum of white lamps to investigate the influence of spectral composition on number of arthropods attracted. We compared numbers of arthropods captured at three customizable light-emitting diode (LED) lamps (3510, 2704 and 2728 K), two commercial LED lamps (2700 K), two commercial compact fluorescent lamps (CFLs; 2700 K) and a control. We configured the three custom LEDs to minimize invertebrate attraction based on published attraction curves for honeybees and moths. Lamps were placed with pan traps at an urban and two rural study sites in Los Angeles, California. For all invertebrate orders combined, our custom LED configurations were less attractive than the commercial LED lamps or CFLs of similar colour temperatures. Thus, adjusting spectral composition of white light to minimize attracting nocturnal arthropods is feasible; not all lights with the same colour temperature are equally attractive to arthropods. PMID:25780237
Radiation in controlled environments: influence of lamp type and filter material
NASA Technical Reports Server (NTRS)
Bubenheim, D. L.; Bugbee, B.; Salisbury, F. B.
1988-01-01
Radiation in controlled environments was characterized using fluorescent and various high-intensity-discharge (HID) lamps, including metal halide, low-pressure sodium, and high-pressure sodium as the radiation source. The effects of water, glass, or Plexiglas filters on radiation were determined. Photosynthetic photon flux (PPF, 400 to 700 nm), spectra (400 to 1000 nm), shortwave radiation (285-2800 nm), and total radiation (300 to 100,000 nm) were measured, and photosynthetically active radiation (PAR, 400 to 700 nm) and longwave radiation (2800 to 100,000 nm) were calculated. Measurement of PPF alone was not an adequate characterization of the radiation environment. Total radiant flux varied among lamp types at equal PPF. HID lamps provided a lower percentage of longwave radiation than fluorescent lamps, but, when HID lamps provided PPF levels greater than that possible with fluorescent lamps, the amount of longwave radiation was high. Water was the most effective longwave radiation filter. Glass and Plexiglas similarly filtered longwave more than shortwave radiation, but transmission of nonphotosynthetic shortwave radiation was less with Plexiglas than glass. The filter materials tested would not be expected to influence photomorphogenesis because radiation in the action spectrum of phytochrome was not altered, but this may not be the only pigment involved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuenge, Jason R.; Hollomon, Brad; Dillon, Heather E.
This report covers the third part of a larger U.S. Department of Energy (DOE) project to assess the life-cycle environmental and resource impacts in the manufacturing, transport, use, and disposal of light-emitting diode (LED) lighting products in relation to incumbent lighting technologies. All three reports are available on the DOE website (www.ssl.energy.gov/tech_reports.html). • Part 1: Review of the Life-Cycle Energy Consumption of Incandescent, Compact Fluorescent and LED Lamps; • Part 2: LED Manufacturing and Performance; • Part 3: LED Environmental Testing. Parts 1 and 2 were published in February and June 2012, respectively. The Part 1 report included a summarymore » of the life-cycle assessment (LCA) process and methodology, provided a literature review of more than 25 existing LCA studies of various lamp types, and performed a meta-analysis comparing LED lamps with incandescent and compact fluorescent lamps (CFLs). Drawing from the Part 1 findings, Part 2 performed a more detailed assessment of the LED manufacturing process and used these findings to provide a comparative LCA taking into consideration a wider range of environmental impacts. Both reports concluded that the life-cycle environmental impact of a given lamp is dominated by the energy used during lamp operation—the upstream generation of electricity drives the total environmental footprint of the product. However, a more detailed understanding of end-of-life disposal considerations for LED products has become increasingly important as their installation base has grown. The Part 3 study (reported herein) was undertaken to augment the LCA findings with chemical analysis of a variety of LED, CFL, and incandescent lamps using standard testing procedures. A total of 22 samples, representing 11 different models, were tested to determine whether any of 17 elements were present at levels exceeding California or Federal regulatory thresholds for hazardous waste. Key findings include: • The selected models were generally found to be below thresholds for Federally regulated elements; • All CFLs and LED lamps and most incandescent lamps exceeded California thresholds for Copper; • Most CFL samples exceeded California thresholds for Antimony and Nickel, and half of the LED samples exceeded California thresholds for Zinc; • The greatest contributors were the screw bases, drivers, ballasts, and wires or filaments; • Overall concentrations in LED lamps were comparable to cell phones and other types of electronic devices, and were generally attributable to components other than the internal LED light sources; • Although the life-cycle environmental impact of the LED lamps is favorable when compared to CFLs and incandescent lamps, recycling will likely gain importance as consumer adoption increases. This study was exploratory in nature and was not intended to provide a definitive indication of regulatory compliance for any specific lamp model or technology. Further study would be needed to more broadly characterize the various light source technologies; to more accurately and precisely characterize a specific model; or to determine whether product redesign would be appropriate.« less
Wang, Lu; Wang, Jingbo; Cai, Weile; Shi, Yongquan; Zhou, Xinmin; Guo, Guanya; Guo, Changcun; Huang, Xiaofeng; Han, Zheyi; Zhang, Shuai; Ma, Shuoyi; Zhou, Xia; Fan, Daiming; Gershwin, M Eric; Han, Ying
2017-08-01
Danon disease is a genetic deficiency in lysosome-associated membrane protein 2 (LAMP-2), a highly glycosylated constituent of the lysosomal membrane and characterized by a cardiomyopathy, skeletal muscle myopathy, and cognitive impairment. Patients, however, often manifest hepatic abnormalities, but liver function has not been well evaluated and the syndrome is relatively uncommon. Hence, we have taken advantage of a rat that has been deleted of LAMP-2 to study the relative role of LAMP-2 on liver function. Interestingly, rats deficient in LAMP-2 develop a striking increase in serum alkaline phosphatase (ALP) and a decrease in bile flow compared with wild-type littermates. Importantly and by ultrastructural analysis, deficient rats manifest dilated canaliculi that lack microvilli with evidence of bile-containing bodies. Moreover, following bile duct ligation, LAMP-2-deficient rats develop rapid and severe evidence of advanced cholestasis, with an increase in serum bilirubin, as early as 6 h later. In wild-type control rats, multidrug resistance-associated protein 2 (Mrp2) normally concentrates at the bile canalicular membranes to secrete conjugated bilirubin into bile. However, in LAMP-2 y/- rats, Mrp2 was detected in hepatocytes compared with other canalicular proteins including P-glycoproteins, dipeptidyl peptidase IV (CD26), and aminopeptidase (CD13). Our data further suggest that LAMP-2 interacts with the membrane cytoskeletal proteins radixin and F-actin in determining the localization of integral membrane proteins.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Innocenzi, V., E-mail: valentina.innocenzi1@univaq.it; De Michelis, I.; Ferella, F.
2013-11-15
Highlights: • Fluorescent powder of lamps. • Fluorescent powder of cathode ray rubes. • Recovery of yttrium from fluorescent powders. • Economic simulation for the processes to recover yttrium from WEEE. - Abstract: In this paper, yttrium recovery from fluorescent powder of lamps and cathode ray tubes (CRTs) is described. The process for treating these materials includes the following: (a) acid leaching, (b) purification of the leach liquors using sodium hydroxide and sodium sulfide, (c) precipitation of yttrium using oxalic acid, and (d) calcinations of oxalates for production of yttrium oxides. Experimental results have shown that process conditions necessary tomore » purify the solutions and recover yttrium strongly depend on composition of the leach liquor, in other words, whether the powder comes from treatment of CRTs or lamp. In the optimal experimental conditions, the recoveries of yttrium oxide are about 95%, 55%, and 65% for CRT, lamps, and CRT/lamp mixture (called MIX) powders, respectively. The lower yields obtained during treatments of MIX and lamp powders are probably due to the co-precipitation of yttrium together with other metals contained in the lamps powder only. Yttrium loss can be reduced to minimum changing the experimental conditions with respect to the case of the CRT process. In any case, the purity of final products from CRT, lamps, and MIX is greater than 95%. Moreover, the possibility to treat simultaneously both CRT and lamp powders is very important and interesting from an industrial point of view since it could be possible to run a single plant treating fluorescent powder coming from two different electronic wastes.« less
10 CFR 430.35 - Petitions with respect to general service lamps.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 430.35 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Energy and Water Conservation Standards § 430.35 Petitions with respect to general service lamps... exemption for a product under this paragraph, the Secretary shall include, as an additional criterion, that...
10 CFR 430.35 - Petitions with respect to general service lamps.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 430.35 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Energy and Water Conservation Standards § 430.35 Petitions with respect to general service lamps... exemption for a product under this paragraph, the Secretary shall include, as an additional criterion, that...
10 CFR 430.35 - Petitions with respect to general service lamps.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 430.35 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Energy and Water Conservation Standards § 430.35 Petitions with respect to general service lamps... exemption for a product under this paragraph, the Secretary shall include, as an additional criterion, that...
10 CFR 430.35 - Petitions with respect to general service lamps.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Section 430.35 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Energy and Water Conservation Standards § 430.35 Petitions with respect to general service lamps... exemption for a product under this paragraph, the Secretary shall include, as an additional criterion, that...
Advanced lighting guidelines: 1993. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eley, C.; Tolen, T.M.; Benya, J.R.
1993-12-31
The 1993 Advanced Lighting Guidelines document consists of twelve guidelines that provide an overview of specific lighting technologies and design application techniques utilizing energy-efficient lighting practice. Lighting Design Practice assesses energy-efficient lighting strategies, discusses lighting issues, and explains how to obtain quality lighting design and consulting services. Luminaires and Lighting Systems surveys luminaire equipment designed to take advantage of advanced technology lamp products and includes performance tables that allow for accurate estimation of luminaire light output and power input. The additional ten guidelines -- Computer-Aided Lighting Design, Energy-Efficient Fluorescent Ballasts, Full-Size Fluorescent Lamps, Compact Fluorescent Lamps, Tungsten-Halogen Lamps, Metal Halidemore » and HPS Lamps, Daylighting and Lumen Maintenance, Occupant Sensors, Time Scheduling Systems, and Retrofit Control Technologies -- each provide a product technology overview, discuss current products on the lighting equipment market, and provide application techniques. This document is intended for use by electric utility personnel involved in lighting programs, lighting designers, electrical engineers, architects, lighting manufacturers` representatives, and other lighting professionals.« less
Experimental and theoretical investigations on the warm-up of a high-pressure mercury discharge lamp
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zalach, J.; Franke, St.; Schoepp, H.
2011-03-15
Modern high-pressure discharge lamps are forced to provide instant light and hot relight capabilities - if possible at lower power units. A detailed understanding of the warm-up of high-pressure discharge lamps is therefore required. Complex fluid model codes were developed for the past years including more and more processes like two-dimensional treatment of convection trying to provide a more comprehensive and consistent description of high-pressure discharge lamps. However, there is a lack of experimental data to examine the performance of these models. This work provides a very complete set of geometrical, electrical, spectroscopic, and thermographic data according to the warm-upmore » of a high-pressure mercury discharge lamp that is compared to the results of a state of the art fluid code. Quantitative agreement is achieved for single parameters like wall temperatures. But the paper also reveals the need for further investigations and improvements of the code.« less
[Principle of LAMP method--a simple and rapid gene amplification method].
Ushikubo, Hiroshi
2004-06-01
So far nucleic acid test (NAT) has been employed in various fields, including infectious disease diagnoses. However, due to its complicated procedures and relatively high cost, it has not been widely utilized in many actual diagnostic applications. We have therefore developed a simple and rapid gene amplification technology, Loop-mediated Isothermal Amplification (LAMP) method, which has shown prominent results of surpassing the performance of the conventional gene amplification methods. LAMP method acquires three main features: (1) all reaction can be carried out under isothermal conditions; (2) the amplification efficiency is extremely high and tremendous amount of amplification products can be obtained; and (3) the reaction is highly specific. Furthermore, developed from the standard LAMP method, a rapid LAMP method, by adding in the loop primers, can reduce the amplification time from the previous 1 hour to less than 30 minutes. Enormous amount of white precipitate of magnesium pyrophosphate is produced as a by-product of the amplification, therefore, direct visual detection is possible without using any reaction indicators and detection equipments. We believe LAMP technology, with the integration of these features, can rightly apply to clinical genetic testing, food and environmental analysis, as well as NAT in different fields.
Sze, Robert C.; Bigio, Irving J.
2003-07-15
A high pressure neon arc lamp and method of using the same for photodynamic therapies is provided. The high pressure neon arc lamp includes a housing that encloses a quantity of neon gas pressurized to about 500 Torr to about 22,000 Torr. At each end of the housing the lamp is connected by electrodes and wires to a pulse generator. The pulse generator generates an initial pulse voltage to breakdown the impedance of the neon gas. Then the pulse generator delivers a current through the neon gas to create an electrical arc that emits light having wavelengths from about 620 nanometers to about 645 nanometers. A method for activating a photosensitizer is provided. Initially, a photosensitizer is administered to a patient and allowed time to be absorbed into target cells. Then the high pressure neon arc lamp is used to illuminate the target cells with red light having wavelengths from about 620 nanometers to about 645 nanometers. The red light activates the photosensitizers to start a chain reaction that may involve oxygen free radicals to destroy the target cells. In this manner, a high pressure neon arc lamp that is inexpensive and efficiently generates red light useful in photodynamic therapy is provided.
Hulseberg, Christine E; Fénéant, Lucie; Szymańska, Katarzyna M; White, Judith M
2018-01-02
Lassa virus (LASV) is an arenavirus whose entry into host cells is mediated by a glycoprotein complex (GPC) comprised of a receptor binding subunit, GP1, a fusogenic transmembrane subunit, GP2, and a stable signal peptide. After receptor-mediated internalization, arenaviruses converge in the endocytic pathway, where they are thought to undergo low-pH-triggered, GPC-mediated fusion with a late endosome membrane. A unique feature of LASV entry is a pH-dependent switch from a primary cell surface receptor (α-dystroglycan) to an endosomal receptor, lysosomal-associated membrane protein (Lamp1). Despite evidence that the interaction between LASV GP1 and Lamp1 is critical, the function of Lamp1 in promoting LASV infection remains poorly characterized. Here we used wild-type (WT) and Lamp1 knockout (KO) cells to show that Lamp1 increases the efficiency of, but is not absolutely required for, LASV entry and infection. We then used cell-cell and pseudovirus-cell surface fusion assays to demonstrate that LASV GPC-mediated fusion occurs at a significantly higher pH when Lamp1 is present compared to when Lamp1 is missing. Correspondingly, we found that LASV entry occurs through less acidic endosomes in WT (Lamp1-positive) versus Lamp1 KO cells. We propose that, by elevating the pH threshold for fusion, Lamp1 allows LASV particles to exit the endocytic pathway before they encounter an increasingly acidic and harsh proteolytic environment, which could inactivate a significant percentage of incoming viruses. In this manner Lamp1 increases the overall efficiency of LASV entry and infection. IMPORTANCE Lassa virus is the most clinically important member of the Arenaviridae , a family that includes six additional biosafety level 4 (BSL4) hemorrhagic fever viruses. The lack of specific antiviral therapies for Lassa fever drives an urgent need to identify druggable targets, and interventions that block infection at the entry stage are particularly attractive. Lassa virus is only the second virus known to employ an intracellular receptor, the first being Ebola virus. Here we show that interaction with its intracellular receptor, Lamp1, enhances and upwardly shifts the pH dependence of fusion and consistently permits Lassa virus entry into cells through less acidic endosomes. We propose that in this manner, Lamp1 increases the overall efficiency of Lassa virus infection. Copyright © 2018 Hulseberg et al.
Design and physical features of inductive coaxial copper vapor lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batenin, V. M.; Kazaryan, M. A.; Karpukhin, V. T.
A physical model of a copper vapor laser pumped by a pulse-periodic inductive (electrodeless) discharge is considered. The feasibility of efficient laser pumping by an inductive discharge and reaching high output parameters comparable to those of conventional copper vapor lasers pumped by a longitudinal electrode discharge is demonstrated. The design and physical features of an inductive copper vapor laser with an annular working volume are discussed.
Vallejo, Andrés F.; Martínez, Nora L.; González, Iveth J.; Arévalo-Herrera, Myriam; Herrera, Sócrates
2015-01-01
Background Most commonly used malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections which are frequent in low transmission settings. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too laborious for field deployment. In this study, the applicability of a malaria diagnosis kit based on loop-mediated isothermal amplification (mLAMP) was assessed in malaria endemic areas of Colombia with Plasmodium vivax predominance. Methodology/Principal Findings First, a passive case detection (PCD) study on 278 febrile patients recruited in Tierralta (department of Cordoba) was conducted to assess the diagnostic performance of the mLAMP method. Second, an active case detection (ACD) study on 980 volunteers was conducted in 10 sentinel sites with different epidemiological profiles. Whole blood samples were processed for microscopic and mLAMP diagnosis. Additionally RT-PCR and nested RT-PCR were used as reference tests. In the PCD study, P. falciparum accounted for 23.9% and P. vivax for 76.1% of the infections and no cases of mixed-infections were identified. Microscopy sensitivity for P. falciparum and P. vivax were 100% and 86.1%, respectively. mLAMP sensitivity for P. falciparum and P. vivax was 100% and 91.4%, respectively. In the ACD study, mLAMP detected 65 times more cases than microscopy. A high proportion (98.0%) of the infections detected by mLAMP was from volunteers without symptoms. Conclusions/Significance mLAMP sensitivity and specificity were comparable to RT-PCR. LAMP was significantly superior to microscopy and in P. vivax low-endemicity settings and under minimum infrastructure conditions, it displayed sensitivity and specificity similar to that of single-well RT-PCR for detection of both P. falciparum and P. vivax infections. Here, the dramatically increased detection of asymptomatic malaria infections by mLAMP demonstrates the usefulness of this new tool for diagnosis, surveillance, and screening in elimination strategies. PMID:25569550
Sheu, Shyang-Chwen; Tsou, Po-Chuan; Lien, Yi-Yang; Lee, Meng-Shiou
2018-08-15
Peanut is a widely and common used in many cuisines around the world. However, peanut is also one of the most important food allergen for causing anaphylactic reaction. To prevent allergic reaction, the best way is to avoid the food allergen or food containing allergic ingredient such as peanut before food consuming. Thus, to efficient and precisely detect the allergic ingredient, peanut or related product, is essential and required for maintain consumer's health or their interest. In this study, a loop-mediated isothermal amplification (LAMP) assay was developed for the detection of allergic peanut using specifically designed primer sets. Two sets of the specific LAMP primers respectively targeted the internal transcribed sequence 1 (ITS1) of nuclear ribosomal DNA sequence regions and the ara h1 gene sequence of Arachia hypogeae (peanut) were used to address the application of LAMP for detecting peanut in processed food or diet. The results demonstrated that the identification of peanut using the newly designed primers for ITS 1 sequence is more sensitive rather than primers for sequence of Ara h1 gene when performing LAMP assay. Besides, the sensitivity of LAMP for detecting peanut is also higher than the traditional PCR method. These LAMP primers sets showed high specificity for the identification of the peanut and had no cross-reaction to other species of nut including walnut, hazelnut, almonds, cashew and macadamia nut. Moreover, when minimal 0.1% peanuts were mixed with other nuts ingredients at different ratios, no any cross-reactivity was evident during performing LAMP. Finally, genomic DNAs extracted from boiled and steamed peanut were used as templates; the detection of peanut by LAMP was not affected and reproducible. As to this established LAMP herein, not only can peanut ingredients be detected but commercial foods containing peanut can also be identified. This assay will be useful and potential for the rapid detection of peanut in practical food markets. Copyright © 2018 Elsevier Ltd. All rights reserved.
Grab, Dennis J; Nikolskaia, Olga V; Inoue, Noboru; Thekisoe, Oriel M M; Morrison, Liam J; Gibson, Wendy; Dumler, J Stephen
2011-08-01
The loop-mediated isothermal amplification (LAMP) assay, with its advantages of simplicity, rapidity and cost effectiveness, has evolved as one of the most sensitive and specific methods for the detection of a broad range of pathogenic microorganisms including African trypanosomes. While many LAMP-based assays are sufficiently sensitive to detect DNA well below the amount present in a single parasite, the detection limit of the assay is restricted by the number of parasites present in the volume of sample assayed; i.e. 1 per µL or 10(3) per mL. We hypothesized that clinical sensitivities that mimic analytical limits based on parasite DNA could be approached or even obtained by simply adding detergent to the samples prior to LAMP assay. For proof of principle we used two different LAMP assays capable of detecting 0.1 fg genomic DNA (0.001 parasite). The assay was tested on dilution series of intact bloodstream form Trypanosoma brucei rhodesiense in human cerebrospinal fluid (CSF) or blood with or without the addition of the detergent Triton X-100 and 60 min incubation at ambient temperature. With human CSF and in the absence of detergent, the LAMP detection limit for live intact parasites using 1 µL of CSF as the source of template was at best 10(3) parasites/mL. Remarkably, detergent enhanced LAMP assay reaches sensitivity about 100 to 1000-fold lower; i.e. 10 to 1 parasite/mL. Similar detergent-mediated increases in LAMP assay analytical sensitivity were also found using DNA extracted from filter paper cards containing blood pretreated with detergent before card spotting or blood samples spotted on detergent pretreated cards. This simple procedure for the enhanced detection of live African trypanosomes in biological fluids by LAMP paves the way for the adaptation of LAMP for the economical and sensitive diagnosis of other protozoan parasites and microorganisms that cause diseases that plague the developing world.
NASA Astrophysics Data System (ADS)
Miccio, L.; Vespini, V.; Grilli, S.; Paturzo, M.; Finizio, A.; De Nicola, S.; Ferraro, P.
2009-06-01
We show how thin liquid film on polar dielectric substrate can form an array of liquid micro-lenses. The effect is driven by the pyroelectric effect leading to a new concept in electro-wetting (EW). EW is a viable method for actuation of liquids in microfluidic systems and requires the design and fabrication of complex electrodes for suitable actuation of liquids. When compared to conventional electrowetting devices, the pyroelectric effect allowed to have an electrode-less and circuitless configuration. In our case the surface electric charge induced by the thermal stimulus is able to pattern selectively the surface wettability according to geometry of the ferroelectric domains micro-engineered into the lithium niobate crystal. We show that different geometries of liquid microlenses can be obtained showing also a tuneability of the focal lenses down to 1.6 mm. Thousand of liquid microlenses, each with 100 μm diameter, can be formed and actuated. Also different geometries such as hemi-cylindrical and toroidal liquid structures can be easily obtained. By means of a digital holography method, an accurate characterization of the micro-lenses curvature is performed and presented. The preliminary results concerning the imaging capability of the micro-lens array are also reported. Microlens array can find application in medical stereo-endoscopy, imaging, telecommunication and optical data storage too.
LAMPS software and mesoscale prediction studies
NASA Technical Reports Server (NTRS)
Perkey, D. J.
1985-01-01
The full-physics version of the LAMPS model has been implemented on the Perkin-Elmer computer. In Addition, LAMPS graphics processors have been rewritten to the run on the Perkin-Elmer and they are currently undergoing final testing. Numerical experiments investigating the impact of convective parameterized latent heat release on the evolution of a precipitating storm have been performed and the results are currently being evaluated. Curent efforts include the continued evaluation of the impact of initial conditions on LAMPS model results. This work will help define measurement requirements for future research field projects as well as for observations in support of operational forecasts. Also, the impact of parameterized latent heat on the evolution of precipitating systems is continuing. This research is in support of NASA's proposed Earth Observation Mission (EOM).
Light Sources and Lighting Circuits
NASA Astrophysics Data System (ADS)
Honda, Hisashi; Suwa, Takumi; Yasuda, Takeo; Ohtani, Yoshihiko; Maehara, Akiyoshi; Okada, Atsunori; Komatsu, Naoki; Mannami, Tomoaki
According to the Machinery Statistics of the Ministry of Economy, Trade and Industry, the production of incandescent lamps in Japan in 2007 was 990 million units (90.0% of the previous year's total), in which the production of incandescent lamps for general lighting was 110 million units (90.0% of the previous year's total) and of tungsten-halogen lamps was 44 million units (96.6% of the previous year's total). The production of fluorescent lamps was 927 million units (93.9% of the previous year's total), in which general fluorescent lamps, excluding those for LCD back lighting, was 320 million units (87.2% of the previous year's total). Also, the production of HID lamps was 10 million units (101.5% of the previous year's total). On the other hand, when the numbers of sales are compared with the sales of the previous year, incandescent lamps for general use was 99.8%, tungsten-halogen lamps was 96.9%, fluorescent lamps was 95.9%, and HID lamps was 98.9%. Self-ballasted fluorescent lamps alone showed an increase in sales as strong as 29 million units, or 121.7% of the previous year's sales. It is considered that the switchover of incandescent lamps to HID lamps was promoted for energy conservation and carbon dioxide reduction with the problem of global warming in the background. In regard to exhibitions, Lighting Fair 2007 was held in Tokyo in March, and LIGHTFAIR INTERNATIONAL 2007 was held in New York in May. Regarding academic conferences, LS:11 (the 11th International Symposium on the Science & Technology of Light Sources) was held in Shanghai in May, and the First International Conference on White LEDs and Solid State Lighting was held in Tokyo in November. Both conferences suggested that there are strong needs and concerns now about energy conservation, saving natural resources, and restrictions of hazardous materials. In regard to incandescent lamps, the development of products aiming at higher efficacy, electric power savings, and longer life was advanced by means of using filler gas with a higher atomic weight. Regarding fluorescent lamps, studies and developments for longer operating life and improvement in the lumen maintenance factor for the straight-type and circular-type fluorescent lamps were actively pursued. Regarding self-ballasted fluorescent lamps, the main stream of development was aimed at reducing lamp size and increasing energy conservation, and the development of new products that took advantage of these features proceeded. In regard to LED light sources, basic research and product development, including new application development, were vigorously implemented. In basic research, studies were reported, not only on efficacy improvements through optimization of the LED chips, phosphor layers, and packaging technology, but also on photometry, colorimetry, and visual psychology. In the field of application, applications were studied for general lighting sources and also for a wide range of fields, such as automotive headlights and visible light communication. Also, many academic conferences and exhibitions were held domestically and overseas, and the high level of interest suggests high expectations for this next-generation light source. Regarding HID lamps, there was much activity in research and development and in the commercialization of the ceramic metal halide lamp product, and products were commercialized with features such as higher efficiency (130 lm/W) and higher color rendering properties (R9 ≥ 90). In the high-pressure sodium lamps, there were many study reports concerning plant growth and insect pest control using its low insect-attracting characteristics. With high-pressure mercury lamps, there were many reports on reducing lamp size and increasing intensity for use as a light source for projectors.
Lysosome-associated membrane proteins-1 and -2 (LAMP-1 and LAMP-2) assemble via distinct modes.
Terasawa, Kazue; Tomabechi, Yuri; Ikeda, Mariko; Ehara, Haruhiko; Kukimoto-Niino, Mutsuko; Wakiyama, Motoaki; Podyma-Inoue, Katarzyna A; Rajapakshe, Anupama R; Watabe, Tetsuro; Shirouzu, Mikako; Hara-Yokoyama, Miki
2016-10-21
Lysosome-associated membrane proteins 1 and 2 (LAMP-1 and LAMP-2) have a large, heavily glycosylated luminal domain composed of two subdomains, and are the most abundant protein components in lysosome membranes. LAMP-1 and LAMP-2 have distinct functions, and the presence of both proteins together is required for the essential regulation of autophagy to avoid embryonic lethality. However, the structural aspects of LAMP-1 and LAMP-2 have not been elucidated. In the present study, we demonstrated that the subdomains of LAMP-1 and LAMP-2 adopt the unique β-prism fold, similar to the domain structure of the dendritic cell-specific-LAMP (DC-LAMP, LAMP-3), confirming the conserved aspect of this family of lysosome-associated membrane proteins. Furthermore, we evaluated the effects of the N-domain truncation of LAMP-1 or LAMP-2 on the assembly of LAMPs, based on immunoprecipitation experiments. We found that the N-domain of LAMP-1 is necessary, whereas that of LAMP-2 is repressive, for the organization of a multimeric assembly of LAMPs. Accordingly, the present study suggests for the first time that the assembly modes of LAMP-1 and LAMP-2 are different, which may underlie their distinct functions. Copyright © 2016 Elsevier Inc. All rights reserved.
Expression of the lysosomal-associated membrane protein-1 (LAMP-1) in astrocytomas
Jensen, Stine S; Aaberg-Jessen, Charlotte; Christensen, Karina G; Kristensen, Bjarne
2013-01-01
Targeting of lysosomes is a novel therapeutic anti-cancer strategy for killing the otherwise apoptosis-resistant cancer cells. Such strategies are urgently needed for treatment of brain tumors, especially the glioblastoma, which is the most frequent and most malignant type. The aim of the present study was to investigate the presence of lysosomes in astrocytic brain tumors focussing also on the therapy resistant tumor stem cells. Expression of the lysosomal marker LAMP-1 (lysosomal-associated membrane protein-1) was investigated by immunohistochemistry in 112 formalin fixed paraffin embedded astrocytomas and compared with tumor grade and overall patient survival. Moreover, double immunofluorescence stainings were performed with LAMP-1 and the astrocytic marker GFAP and the putative stem cell marker CD133 on ten glioblastomas. Most tumors expressed the LAMP-1 protein in the cytoplasm of the tumor cells, while the blood vessels were positive in all tumors. The percentage of LAMP-1 positive tumor cells and staining intensities increased with tumor grade but variations in tumors of the same grade were also found. No association was found between LAMP-1 expression and patient overall survival in the individual tumor grades. LAMP-1/GFAP showed pronounced co-expression and LAMP-1/CD133 was co-expressed as well suggesting that tumor cells including the proposed tumor stem cells contain lysosomes. The results suggest that high amounts of lysosomes are present in glioblastomas and in the proposed tumor stem cells. Targeting of lysosomes may be a promising novel therapeutic strategy against this highly malignant neoplasm. PMID:23826410
The Photoluminescence of a Fluorescent Lamp: Didactic Experiments on the Exponential Decay
ERIC Educational Resources Information Center
Onorato, Pasquale; Gratton, Luigi; Malgieri, Massimiliano; Oss, Stefano
2017-01-01
The lifetimes of the photoluminescent compounds contained in the coating of fluorescent compact lamps are usually measured using specialised instruments, including pulsed lasers and/or spectrofluorometers. Here we discuss how some low cost apparatuses, based on the use of either sensors for the educational lab or commercial digital photo cameras,…
Photochemical method for generating superoxide radicals (O.sub.2.sup.-) in aqueous solutions
Holroyd, Richard A.; Bielski, Benon H. J.
1980-01-01
A photochemical method and apparatus for generating superoxide radicals (ub.2.sup.-) in an aqueous solution by means of a vacuum-ultraviolet lamp of simple design. The lamp is a microwave powered rare gas device that emits far-ultraviolet light. The lamp includes an inner loop of high purity quartz tubing through which flows an oxygen-saturated sodium formate solution. The inner loop is designed so that the solution is subjected to an intense flux of far-ultraviolet light. This causes the solution to photodecompose and form the product radical (O.sub.2.sup.-).
The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis
Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio
2015-01-01
Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990
NASA Astrophysics Data System (ADS)
Bokhtache, Aicha Aissa; Zegaoui, Abdallah; Aillerie, Michel; Djahbar, Abdelkader; Hemici, Kheira
2018-05-01
Electronic ballasts dedicated to discharge lamps allow improving the quality of radiation by operating at high frequency. In the present work, the use of a single-phase direct converter with a matrix structure for supplying a low-pressure mercury-argon UVC lamp for water sterilization is proposed. The structure of the converter is based on two switching cells allowing the realization of a fully controllable bidirectional switches. The advantages of such a matrix topology include the delivered of a sinusoidal waveform current with a controllable power factor close to unity, variable in amplitude and frequency. In order to obtain the desired amplitude and frequency, a PWM control was associated in the current realization. Finally, a linear adjustment of the lamp arc current was warranted by using of a PI regulator.
Tegegne, Banchamlak; Getie, Sisay; Lemma, Wossenseged; Mohon, Abu Naser; Pillai, Dylan R
2017-01-19
Malaria is a major public health problem and an important cause of maternal and infant morbidity in sub-Saharan Africa, including Ethiopia. Early and accurate diagnosis of malaria with effective treatment is the best strategy for prevention and control of complications during pregnancy and infant morbidity and mortality. However, laboratory diagnosis has relied on the identification of malaria parasites and parasite antigens in peripheral blood using Giemsa-stained microscopy or rapid diagnostic tests (RDTs) which lack analytical and clinical sensitivity. The aim of this study was to evaluate the performance of loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria among malaria suspected pregnant women in Northwest Ethiopia. A cross sectional study was conducted from January to April 2016. Pregnant women (n = 87) suspected of having malaria at six health centres were enrolled. A venous blood sample was collected from each study subject, and analysed for Plasmodium parasites by microscopy, RDT, and LAMP. Diagnostic accuracy outcome measures (sensitivity, specificity, predictive values, and Kappa scores) of microscopy, RDT and LAMP were compared to nested polymerase chain reaction (nPCR) as the gold standard. Specimen processing and reporting times were documented. Using nPCR as the gold standard technique, the sensitivity of microscopy and RDT was 90 and 70%, and the specificity was 98.7 and 97.4%, respectively. LAMP assay was 100% sensitive and 93.5% specific compared to nPCR. This study showed higher sensitivity of LAMP compared to microscopy and RDT for the detection of malaria in pregnancy. Increased sensitivity and ease of use with LAMP in point-of-care testing for malaria in pregnancy was noted. LAMP warrants further evaluation in intermittent screening and treatment programmes in pregnancy.
Manajit, Orapan; Longyant, Siwaporn; Sithigorngul, Paisarn; Chaivisuthangkura, Parin
2018-04-01
Pseudomonas aeruginosa (P. aeruginosa) is an important opportunistic pathogen that causes serious infections in humans, including keratitis in contact lens wearers. Therefore, establishing a rapid, specific and sensitive method for the identification of P. aeruginosa is imperative. In the present study, the uracil-DNA-glycosylase-supplemented loop-mediated isothermal amplification combined with nanogold labeled hybridization probe (UDG-LAMP-AuNP) was developed for the detection of P. aeruginosa. UDG-LAMP was performed to prevent carry over contamination and the LAMP reactions can be readily observed using the nanogold probe. A set of 4 primers and a hybridization probe were designed based on the ecfX gene. The UDG-LAMP reactions were performed at 65˚C for 60 min using the ratio of 40% deoxyuridine triphosphate to 60% deoxythymidine triphosphate. The detection of UDG-LAMP products using the nanogold labeled hybridization probe, which appeared as a red-purple color, was examined at 65˚C for 5 min with 40 mM MgSO4. The UDG-LAMP-AuNP demonstrated specificity to all tested isolates of P. aeruginosa without cross reaction to other bacteria. The sensitivity for the detection of pure culture was 1.6x103 colony-forming units (CFU) ml-1 or equivalent to 3 CFU per reaction while that of polymerase chain reaction was 30 CFU per reaction. The detection limit of spiked contact lenses was 1.1x103 CFU ml-1 or equivalent to 2 CFU per reaction. In conclusion, the UDG-LAMP-AuNP assay was rapid, simple, specific and was effective for the identification of P. aeruginosa in contaminated samples.
Manajit, Orapan; Longyant, Siwaporn; Sithigorngul, Paisarn; Chaivisuthangkura, Parin
2018-01-01
Pseudomonas aeruginosa (P. aeruginosa) is an important opportunistic pathogen that causes serious infections in humans, including keratitis in contact lens wearers. Therefore, establishing a rapid, specific and sensitive method for the identification of P. aeruginosa is imperative. In the present study, the uracil-DNA-glycosylase-supplemented loop-mediated isothermal amplification combined with nanogold labeled hybridization probe (UDG-LAMP-AuNP) was developed for the detection of P. aeruginosa. UDG-LAMP was performed to prevent carry over contamination and the LAMP reactions can be readily observed using the nanogold probe. A set of 4 primers and a hybridization probe were designed based on the ecfX gene. The UDG-LAMP reactions were performed at 65°C for 60 min using the ratio of 40% deoxyuridine triphosphate to 60% deoxythymidine triphosphate. The detection of UDG-LAMP products using the nanogold labeled hybridization probe, which appeared as a red-purple color, was examined at 65°C for 5 min with 40 mM MgSO4. The UDG-LAMP-AuNP demonstrated specificity to all tested isolates of P. aeruginosa without cross reaction to other bacteria. The sensitivity for the detection of pure culture was 1.6×103 colony-forming units (CFU) ml−1 or equivalent to 3 CFU per reaction while that of polymerase chain reaction was 30 CFU per reaction. The detection limit of spiked contact lenses was 1.1×103 CFU ml−1 or equivalent to 2 CFU per reaction. In conclusion, the UDG-LAMP-AuNP assay was rapid, simple, specific and was effective for the identification of P. aeruginosa in contaminated samples. PMID:29436623
Tao, Zhi-Yong; Zhou, Hua-Yun; Xia, Hui; Xu, Sui; Zhu, Han-Wu; Culleton, Richard L; Han, Eun-Taek; Lu, Feng; Fang, Qiang; Gu, Ya-Ping; Liu, Yao-Bao; Zhu, Guo-Ding; Wang, Wei-Ming; Li, Ju-Lin; Cao, Jun; Gao, Qi
2011-06-21
Loop-mediated isothermal amplification (LAMP) is a high performance method for detecting DNA and holds promise for use in the molecular detection of infectious pathogens, including Plasmodium spp. However, in most malaria-endemic areas, which are often resource-limited, current LAMP methods are not feasible for diagnosis due to difficulties in accurately interpreting results with problems of sensitive visualization of amplified products, and the risk of contamination resulting from the high quantity of amplified DNA produced. In this study, we establish a novel visualized LAMP method in a closed-tube system, and validate it for the diagnosis of malaria under simulated field conditions. A visualized LAMP method was established by the addition of a microcrystalline wax-dye capsule containing the highly sensitive DNA fluorescence dye SYBR Green I to a normal LAMP reaction prior to the initiation of the reaction. A total of 89 blood samples were collected on filter paper and processed using a simple boiling method for DNA extraction, and then tested by the visualized LAMP method for Plasmodium vivax infection. The wax capsule remained intact during isothermal amplification, and released the DNA dye to the reaction mixture only when the temperature was raised to the melting point following amplification. Soon after cooling down, the solidified wax sealed the reaction mix at the bottom of the tube, thus minimizing the risk of aerosol contamination. Compared to microscopy, the sensitivity and specificity of LAMP were 98.3% (95% confidence interval (CI): 91.1-99.7%) and 100% (95% CI: 88.3-100%), and were in close agreement with a nested polymerase chain reaction method. This novel, cheap and quick visualized LAMP method is feasible for malaria diagnosis in resource-limited field settings.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-15
... assembly (including stoplamp, taillamp, and license plate lamp); and (e) front and rear turn signal lamps... Privacy Act heading below. Privacy Act: Anyone is able to search the electronic form of all comments... recommend that you periodically search the Docket for new material. FOR FURTHER INFORMATION CONTACT: Coleman...
1985-09-01
management and recurring reports generation . Included are the results of user interviews which were conducted to determine oossible system functions...9 A. GENERAL ...................... .......... 3 B. RESEARCH OBJECTIVES ............................ I0 C. SCOPE .. D... GENERAL DESCRIPTION (LAMPS) ...................... 9. LPMrOS CRGANIZAT r.N ............................... C. REPCRT>1NG RECLUIRE,’ENTS
What Happens after They Graduate? Results from a Longitudinal Study of STC Graduates.
ERIC Educational Resources Information Center
MacAllum, Keith; Bozick, Robert
The Lansing Area Manufacturing Partnership (LAMP) is an academically rigorous, business/labor-driven school-to-career (STC) program in Lansing, Michigan, that includes business, union, school, and parent partners. The effects of participation in LAMP on transitions from school to higher education and work were examined in a longitudinal study of…
ERIC Educational Resources Information Center
MacAllum, Keith; Taylor, Susan Hubbard; Johnson, Amy Bell
The Lansing Area Manufacturing Partnership (LAMP) is an academically rigorous, business/labor-driven school-to-career program in Lansing, Michigan, that includes business, union, school, and parent partners and provides participating students with work-based learning experiences for 2.5 hours every day throughout their senior year. LAMP's…
The photoluminescence of a fluorescent lamp: didactic experiments on the exponential decay
NASA Astrophysics Data System (ADS)
Onorato, Pasquale; Gratton, Luigi; Malgieri, Massimiliano; Oss, Stefano
2017-01-01
The lifetimes of the photoluminescent compounds contained in the coating of fluorescent compact lamps are usually measured using specialised instruments, including pulsed lasers and/or spectrofluorometers. Here we discuss how some low cost apparatuses, based on the use of either sensors for the educational lab or commercial digital photo cameras, can be employed to the same aim. The experiments do not require that luminescent phosphors are hazardously extracted from the compact fluorescent lamp, that also contains mercury. We obtain lifetime measurements for specific fluorescent elements of the bulb coating, in good agreement with the known values. We also address the physical mechanisms on which fluorescence lamps are based in a simplified way, suitable for undergraduate students; and we discuss in detail the physics of the lamp switch-off by analysing the time dependent spectrum, measured through a commercial fiber-optic spectrometer. Since the experiment is not hazardous in any way, requires a simple setup up with instruments which are commonly found in educational labs, and focuses on the typical features of the exponential decay, it is suitable for being performed in the undergraduate laboratory.
Nawattanapaiboon, Kawin; Kiatpathomchai, Wansika; Santanirand, Pitak; Vongsakulyanon, Apirom; Amarit, Ratthasart; Somboonkaew, Armote; Sutapun, Boonsong; Srikhirin, Toemsak
2015-12-15
In this study, we evaluated surface plasmon resonance imaging (SPR imaging) as a DNA biosensor for the detection of methicillin-resistant Staphylococcus aureus (MRSA) which is one of the most common causes of nosocomial infections. The DNA sample were collected from clinical specimens, including sputum and blood hemoculture were undergone LAMP amplification for 0.18 kbp and 0.23 kbp DNA fragments of femB and mecA genes, respectively. The self-assembled monolayer surface (SAMs) was used for immobilized streptavidin-biotinylated probes on the sensor surface for the detection of LAMP amplicons from MRSA. Both LAMP amplicons were simultaneously hybridized with ssDNA probes immobilized onto a bio-functionalized surface to detect specific targets in the multiplex DNA array platform. In addition, the sensor surface could be regenerated allowing at least five cycles of use with a shortened assay time. The detection limit of LAMP-SPR sensing was 10 copies/µl and LAMP-SPR sensing system showed a good selectivity toward the MRSA. Copyright © 2015 Elsevier B.V. All rights reserved.
Liu, Zhongyuan; Dong, Zhijun; Liu, Dongyan
2016-07-01
Blooms of the harmful jellyfish Cyanea nozakii, which are a severe nuisance to fisheries and tourisms, frequently occur in the northern East China Sea, Yellow Sea, and Bohai Sea. To provide early warning of this species, a simple and effective molecular method for identifying C. nozakii was developed using the loop-mediated isothermal amplification method (LAMP). The LAMP assay is highly specific and uses a set of four primers that target six different regions on the mitochondrial cytochrome c oxidase subunit I (COI) gene of C. nozakii. The amplification conditions, including the dNTP and betaine concentrations, the inner primer to outer primer concentration ratio, reaction time and temperature, were optimized. The LAMP assay amplified DNA extracted from tissue samples of C. nozakii but did not amplify DNA from other common scyphozoans and hydrozoans collected in the same region. In addition, the LAMP assay was more sensitive than conventional PCR. Therefore, the established LAMP assay is a sensitive, specific, fast, and easily performed method for detection of C. nozakii at different stages in their life cycle.
Kiddle, Guy; Hardinge, Patrick; Buttigieg, Neil; Gandelman, Olga; Pereira, Clint; McElgunn, Cathal J; Rizzoli, Manuela; Jackson, Rebecca; Appleton, Nigel; Moore, Cathy; Tisi, Laurence C; Murray, James A H
2012-04-30
There is an increasing need for quantitative technologies suitable for molecular detection in a variety of settings for applications including food traceability and monitoring of genetically modified (GM) crops and their products through the food processing chain. Conventional molecular diagnostics utilising real-time polymerase chain reaction (RT-PCR) and fluorescence-based determination of amplification require temperature cycling and relatively complex optics. In contrast, isothermal amplification coupled to a bioluminescent output produced in real-time (BART) occurs at a constant temperature and only requires a simple light detection and integration device. Loop mediated isothermal amplification (LAMP) shows robustness to sample-derived inhibitors. Here we show the applicability of coupled LAMP and BART reactions (LAMP-BART) for determination of genetically modified (GM) maize target DNA at low levels of contamination (0.1-5.0% GM) using certified reference material, and compare this to RT-PCR. Results show that conventional DNA extraction methods developed for PCR may not be optimal for LAMP-BART quantification. Additionally, we demonstrate that LAMP is more tolerant to plant sample-derived inhibitors, and show this can be exploited to develop rapid extraction techniques suitable for simple field-based qualitative tests for GM status determination. We also assess the effect of total DNA assay load on LAMP-BART quantitation. LAMP-BART is an effective and sensitive technique for GM detection with significant potential for quantification even at low levels of contamination and in samples derived from crops such as maize with a large genome size. The resilience of LAMP-BART to acidic polysaccharides makes it well suited to rapid sample preparation techniques and hence to both high throughput laboratory settings and to portable GM detection applications. The impact of the plant sample matrix and genome loading within a reaction must be controlled to ensure quantification at low target concentrations.
Angkasekwinai, Nasikarn; Atkins, Erin H.; Johnson, Richard N.; Grieco, John P.; Ching, Wei Mei; Chao, Chien Chung
2014-01-01
Background Carrion' disease, caused by Bartonella bacilliformis, remains truly neglected due to its focal geographical nature. A wide spectrum of clinical manifestations, including asymptomatic bacteremia, and lack of a sensitive diagnostic test can potentially lead to a spread of the disease into non-endemic regions where competent sand fly vectors may be present. A reliable test capable of detecting B. bacilliformis is urgently needed. Our objective is to develop a loop-mediated isothermal amplification (LAMP) assay targeting the pap31 gene to detect B. bacilliformis. Methods and Findings The sensitivity of the LAMP was evaluated in comparison to qPCR using plasmid DNA containing the target gene and genomic DNA in the absence and presence of human or sand fly DNA. The detection limit of LAMP was 1 to 10 copies/µL, depending on the sample metrics. No cross-reaction was observed when testing against a panel of various closely related bacteria. The utility of the LAMP was further compared to qPCR by the examination of 74 Lutzomyia longipalpis sand flies artificially fed on blood spiked with B. bacilliformis and harvested at days (D) 1, 3, 5, 7 and 9 post feeding. Only 86% of sand flies at D1 and 63% of flies at D3 were positive by qPCR. LAMP was able to detect B. bacilliformis in all those flies confirmed positive by qPCR. However, none of the flies after D3 were positive by either LAMP or qPCR. In addition to demonstrating the sensitivity of the LAMP assay, these results suggest that B. bacilliformis cannot propagate in artificially fed L. longipalpis. Conclusions The LAMP assay is as sensitive as qPCR for the detection of B. bacilliformis and could be useful to support diagnosis of patients in low-resource settings and also to identify B. bacilliformis in the sand fly vector. PMID:25522230
NASA Astrophysics Data System (ADS)
Ayuga, Carlos Eugenio Tapia; Zamorano, Jaime
2018-07-01
The night sky spectra of light-polluted areas is the result of the artificial light scattered back from the atmosphere and the reemission of the light after reflections in painted surfaces. This emission comes mainly from street and decorative lamps. We have built an extensive database of lamps spectra covering from UV to near IR and the software needed to analyze them. We describe the LICA-AstroCalc free software that is a user friendly GUI tool to extract information from our database spectra or any other user provided spectrum. The software also includes the complete color database of paints from NCS comprising 1950 types. This helps to evaluate how different colors modify the reflected spectra from different lamps. All spectroscopic measurements have been validated with recommendations from CIELAB and ISO from NCS database.
Optical radiation emissions from compact fluorescent lamps.
Khazova, M; O'Hagan, J B
2008-01-01
There is a drive to energy efficiency to mitigate climate change. To meet this challenge, the UK Government has proposed phasing out incandescent lamps by the end of 2011 and replacing them with energy efficient fluorescent lighting, including compact fluorescent lamps (CFLs) with integrated ballasts. This paper presents a summary of an assessment conducted by the Health Protection Agency in March 2008 to evaluate the optical radiation emissions of CFLs currently available in the UK consumer market. The study concluded that the UV emissions from a significant percentage of the tested CFLs with single envelopes may result in foreseeable overexposure of the skin when these lamps are used in desk or task lighting applications. The optical output of all tested CFLs, in addition to high-frequency modulation, had a 100-Hz envelope with modulation in excess of 15%. This degree of modulation may be linked to a number of adverse effects.
Shader Lamps Virtual Patients: the physical manifestation of virtual patients.
Rivera-Gutierrez, Diego; Welch, Greg; Lincoln, Peter; Whitton, Mary; Cendan, Juan; Chesnutt, David A; Fuchs, Henry; Lok, Benjamin
2012-01-01
We introduce the notion of Shader Lamps Virtual Patients (SLVP) - the combination of projector-based Shader Lamps Avatars and interactive virtual humans. This paradigm uses Shader Lamps Avatars technology to give a 3D physical presence to conversational virtual humans, improving their social interactivity and enabling them to share the physical space with the user. The paradigm scales naturally to multiple viewers, allowing for scenarios where an instructor and multiple students are involved in the training. We have developed a physical-virtual patient for medical students to conduct ophthalmic exams, in an interactive training experience. In this experience, the trainee practices multiple skills simultaneously, including using a surrogate optical instrument in front of a physical head, conversing with the patient about his fears, observing realistic head motion, and practicing patient safety. Here we present a prototype system and results from a preliminary formative evaluation of the system.
Soybean stem growth under high-pressure sodium with supplemental blue lighting
NASA Technical Reports Server (NTRS)
Wheeler, R. M.; Mackowiak, C. L.; Sager, J. C.
1991-01-01
To study high-pressure sodium (HPS) lamps used for plant lighting because of their high energy conversion efficiencies, 'McCall' soybean plants were grown for 28 days in growth chambers utilizing HPS lamps, with/without supplemental light from blue phosphor fluorescent lamps. Total photosynthetic photon flux levels, including blue fluorescent, were maintained near 300 or 500 micromol/sq m s. Results indicate that employment of HPS or other blue-deficient sources for lighting at low to moderate photosynthetic photon flux levels may cause abnormal stem elongation, but this can be prevented by the addition of a small amount of supplemental blue light.
NASA Technical Reports Server (NTRS)
Hurd, W. A.
1985-01-01
Modifications required to change the near ultraviolet source in the Optical Contamination Monitor to a source with output at or near the Lyman-Alpha hydrogen line are discussed. The effort consisted of selecting, acquiring and testing candidate miniature ultraviolet lamps with significant output in or near 121.6 nm. The effort also included selection of a miniature dc high-voltage power supply capable of operating the lamp. The power supply was required to operate from available primary power supplied by the Optical Effect Module (DEM) and it should be flight qualified or have the ability to be qualified by the user.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.; McCullough, Jeffrey J.; Tucker, Joseph C.
The lumen depreciation and color shift of 17 different A lamps (15 LED, 1 CFL, 1 halogen) was monitored in the automated long-term test apparatus (ALTA) for more than 7,500 hours. Ten samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at an ambient temperature of 45°C (-1°C). Importantly, the steady-state test conditions were not optimized for inducing catastrophic failure for any of the lamp technologies—to which thermal cycling is a strong contributor— and are not typical of normal use patterns—which usually include off periods where the lamp cools down.more » Further, the test conditions differ from those used in standardized long-term test methods (i.e., IES LM-80, IES LM-84), so the results should not be directly compared. On the other hand, the test conditions are similar to those used by ENERGY STAR (when elevated temperature testing is called for). Likewise, the conditions and assumptions used by manufacturers to generated lifetime claims may vary; the CALiPER long-term data is informative, but cannot necessarily be used to discredit manufacturer claims. The test method used for this investigation should be interpreted as one more focused on the long-term effects of elevated temperature operation, at an ambient temperature that is not uncommon in luminaires. On average, the lumen maintenance of the LED lamps monitored in the ALTA was better than benchmark lamps, but there was considerable variation from lamp model to lamp model. While three lamp models had average lumen maintenance above 99% at the end of the study period, two products had average lumen maintenance below 65%, constituting a parametric failure. These two products, along with a third, also exhibited substantial color shift, another form of parametric failure. While none of the LED lamps exhibited catastrophic failure—and all of the benchmarks did—the early degradation of performance is concerning, especially with a new technology trying to build a reputation with consumers. Beyond the observed parametric failures nearly half of the products failed to meet early-life thresholds for lumen maintenance, which were borrowed from ENERGY STAR specifications. That is, the lumen maintenance was sufficiently low at 6,000 hours that seven of the products are unlikely to have lumen maintenance above 70% at their rated lifetime (which was usually 25,000 hours). Given the methods used for this investigation—most notably continuous operation—the results should not be interpreted as indicative of a lamp’s performance in a typical environment. Likewise, these results are not directly relatable to manufacturer lifetime claims. This report is best used to understand the variation in LED product performance, compare the robustness of LED lamps and benchmark conventional lamps, and understand the characteristics of lumen and chromaticity change. A key takeaway is that the long-term performance of LED lamps can vary greatly from model to model (i.e., the technology is not homogenous), although the lamp-to-lamp consistency within a given model is relatively good. Further, operation of LED lamps in an enclosed luminaire (or otherwise in high ambient temperatures), can induce parametric failure of LEDs much earlier than their rated lifetime; manufacturer warnings about such conditions should be followed if performance degradation is unacceptable.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.; Beeson, Tracy A.
2014-02-01
The CALiPER program first began investigating LED lamps sold at retail stores in 2010, purchasing 33 products from eight retailers and covering six product categories. The findings revealed a fragmented marketplace, with large disparities in performance of different products, accuracy of manufacturer claims, and offerings from different retail outlets. Although there were some good products, looking back many would not be considered viable competitors to other available options, with too little lumen output, not high enough efficacy, or poor color quality. CALiPER took another look in late 2011purchasing 38 products of five different types from nine retailers and the improvementmore » was marked. Performance was up; retailer claims were more accurate; and the price per lumen and price per unit efficacy were down, although the price per product had not changed much. Nonetheless, there was still plenty of room for improvement, with the performance of LED lamps not yet reaching that of well-established classes of conventional lamps (e.g., 75 W incandescent A19 lamps). Since the second retail lamp study was published in early 2012, there has been substantial progress in all aspects of LED lamps available from retailers. To document this progress, CALiPER again purchased a sample of lamps from retail stores 46 products in total, focusing on A19, PAR30, and MR16 lamps but instead of a random sample, sought to select products to answer specific hypotheses about performance. These hypotheses focused on expanding ranges of LED equivalency, the accuracy of lifetime claims, efficacy and price trends, as well as changes to product designs. Among other results, key findings include: There are now very good LED options to compete with 60 W, 75 W, and 100 W incandescent A19 lamps, and 75 W halogen PAR30 lamps. MR16 lamps have shown less progress, but there are now acceptable alternatives to 35 W, 12 V halogen MR16 lamps and 50 W, 120 V halogen MR16 lamps for some applications. Other uses, such as in enclosed luminaires, may require more development. At the same price point, lamps purchased in 2013 tended to have higher output and slightly higher efficacy than in 2011 or 2010. Over 30% of the products purchased in 2013 exceeded the maximum efficacy measured in 2011 (71 lm/W), with the most efficacious product measured at 105 lm/W. There appears to be increasing consistency in color quality, with a vast majority of products having a CCT of 2700 K or 3000 K and a CRI between 80 and 85. There were also fewer poor performing products tested and more high-performing products available in 2013 than in previous years. The accuracy of equivalency and performance claims was better than in 2011, but remains a concern, with 43% of tested products failing to completely meet their equivalency claim and 20% of products failing to match the manufacturer’s performance data. Although progress has been substantial, on average LED lamps remain more expensive than other energy efficiency lighting technologies -- although some aspects can be superior. Although not universal to all product lines or all product types, the issue of insufficient lumen output from LED lamps is waning. Thus, manufacturers can focus on other issues, such as reducing cost, improving electrical/dimmer compatibility, eliminating flicker, or improving color quality. While these issues are not inherent to all products, they remain a concern for the broader market.« less
49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Requirements for head lamps, auxiliary driving lamps and front fog lamps. 393.24 Section 393.24 Transportation Other Regulations Relating to... MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective...
49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Requirements for head lamps, auxiliary driving lamps and front fog lamps. 393.24 Section 393.24 Transportation Other Regulations Relating to... MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective...
49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Requirements for head lamps, auxiliary driving lamps and front fog lamps. 393.24 Section 393.24 Transportation Other Regulations Relating to... MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meagher, Robert J.; Ball, Cameron Scott; Langevin, Stanley A.
In this study, collection of mosquitoes and testing for vector-borne viruses is a key surveillance activity that directly influences the vector control efforts of public health agencies, including determining when and where to apply insecticides. Vector control districts in California routinely monitor for three human pathogenic viruses including West Nile virus (WNV), Western equine encephalitis virus (WEEV), and St. Louis encephalitis virus (SLEV). Reverse transcription quantitative polymerase chain reaction (RT-qPCR) offers highly sensitive and specific detection of these three viruses in a single multiplex reaction, but this technique requires costly, specialized equipment that is generally only available in centralized publicmore » health laboratories. We report the use of reverse transcription loop-mediated isothermal amplification (RT-LAMP) to detect WNV, WEEV, and SLEV RNA extracted from pooled mosquito samples collected in California, including novel primer sets for specific detection of WEEV and SLEV, targeting the nonstructural protein 4 (nsP4) gene of WEEV and the 3’ untranslated region (3’-UTR) of SLEV. Our WEEV and SLEV RT-LAMP primers allowed detection of <0.1 PFU/reaction of their respective targets in <30 minutes, and exhibited high specificity without cross reactivity when tested against a panel of alphaviruses and flaviviruses. Furthermore, the SLEV primers do not cross-react with WNV, despite both viruses being closely related members of the Japanese encephalitis virus complex. The SLEV and WEEV primers can also be combined in a single RT-LAMP reaction, with discrimination between amplicons by melt curve analysis. Although RT-qPCR is approximately one order of magnitude more sensitive than RT-LAMP for all three targets, the RT-LAMP technique is less instrumentally intensive than RT-qPCR and provides a more cost-effective method of vector-borne virus surveillance.« less
Wheeler, Sarah S.; Ball, Cameron S.; Langevin, Stanley A.; Fang, Ying; Coffey, Lark L.; Meagher, Robert J.
2016-01-01
Collection of mosquitoes and testing for vector-borne viruses is a key surveillance activity that directly influences the vector control efforts of public health agencies, including determining when and where to apply insecticides. Vector control districts in California routinely monitor for three human pathogenic viruses including West Nile virus (WNV), Western equine encephalitis virus (WEEV), and St. Louis encephalitis virus (SLEV). Reverse transcription quantitative polymerase chain reaction (RT-qPCR) offers highly sensitive and specific detection of these three viruses in a single multiplex reaction, but this technique requires costly, specialized equipment that is generally only available in centralized public health laboratories. We report the use of reverse transcription loop-mediated isothermal amplification (RT-LAMP) to detect WNV, WEEV, and SLEV RNA extracted from pooled mosquito samples collected in California, including novel primer sets for specific detection of WEEV and SLEV, targeting the nonstructural protein 4 (nsP4) gene of WEEV and the 3’ untranslated region (3’-UTR) of SLEV. Our WEEV and SLEV RT-LAMP primers allowed detection of <0.1 PFU/reaction of their respective targets in <30 minutes, and exhibited high specificity without cross reactivity when tested against a panel of alphaviruses and flaviviruses. Furthermore, the SLEV primers do not cross-react with WNV, despite both viruses being closely related members of the Japanese encephalitis virus complex. The SLEV and WEEV primers can also be combined in a single RT-LAMP reaction, with discrimination between amplicons by melt curve analysis. Although RT-qPCR is approximately one order of magnitude more sensitive than RT-LAMP for all three targets, the RT-LAMP technique is less instrumentally intensive than RT-qPCR and provides a more cost-effective method of vector-borne virus surveillance. PMID:26807734
STITCHER: A web resource for high-throughput design of primers for overlapping PCR applications.
O'Halloran, Damien M
2015-06-01
Overlapping PCR is routinely used in a wide number of molecular applications. These include stitching PCR fragments together, generating fluorescent transcriptional and translational fusions, inserting mutations, making deletions, and PCR cloning. Overlapping PCR is also used for genotyping by traditional PCR techniques and in detection experiments using techniques such as loop-mediated isothermal amplification (LAMP). STITCHER is a web tool providing a central resource for researchers conducting all types of overlapping PCR experiments with an intuitive interface for automated primer design that's fast, easy to use, and freely available online (http://ohalloranlab.net/STITCHER.html). STITCHER can handle both single sequence and multi-sequence input, and specific features facilitate numerous other PCR applications, including assembly PCR, adapter PCR, and primer walking. Field PCR, and in particular, LAMP, offers promise as an on site tool for pathogen detection in underdeveloped areas, and STITCHER includes off-target detection features for pathogens commonly targeted using LAMP technology.
The LAMP instrument at the Linac Coherent Light Source free-electron laser
NASA Astrophysics Data System (ADS)
Osipov, Timur; Bostedt, Christoph; Castagna, J.-C.; Ferguson, Ken R.; Bucher, Maximilian; Montero, Sebastian C.; Swiggers, Michele L.; Obaid, Razib; Rolles, Daniel; Rudenko, Artem; Bozek, John D.; Berrah, Nora
2018-03-01
The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusive metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false General service fluorescent lamps, general service incandescent lamps, and incandescent reflector lamps. 429.27 Section 429.27 Energy DEPARTMENT OF ENERGY ENERGY... EQUIPMENT Certification § 429.27 General service fluorescent lamps, general service incandescent lamps, and...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false General service fluorescent lamps, general service incandescent lamps, and incandescent reflector lamps. 429.27 Section 429.27 Energy DEPARTMENT OF ENERGY ENERGY... EQUIPMENT Certification § 429.27 General service fluorescent lamps, general service incandescent lamps, and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false General service fluorescent lamps, general service incandescent lamps, and incandescent reflector lamps. 429.27 Section 429.27 Energy DEPARTMENT OF ENERGY ENERGY... EQUIPMENT Certification § 429.27 General service fluorescent lamps, general service incandescent lamps, and...
Chaurey, Vasudha; Rohani, Ali; Su, Yi-Hsuan; Liao, Kuo-Tang; Chou, Chia-Fu; Swami, Nathan S
2013-04-01
Selective trapping of nanoscale bioparticles (size <100 nm) is significant for the separation and high-sensitivity detection of biomarkers. Dielectrophoresis is capable of highly selective trapping of bioparticles based on their characteristic frequency response. However, the trapping forces fall steeply with particle size, especially within physiological media of high-conductivity where the trapping can be dissipated by electrothermal (ET) flow due to localized Joule heating. Herein, we investigate the influence of device scaling within the electrodeless insulator dielectrophoresis geometry through the application of highly constricted channels of successively smaller channel depth, on the net balance of dielectrophoretic trapping force versus ET drag force on bioparticles. While higher degrees of constriction enable dielectrophoretic trapping of successively smaller bioparticles within a short time, the ETflow due to enhanced Joule heating within media of high conductivity can cause a significant dissipation of bioparticle trapping. This dissipative drag force can be reduced through lowering the depth of the highly constricted channels to submicron sizes, which substantially reduces the degree of Joule heating, thereby enhancing the range of voltages and media conductivities that can be applied toward rapid dielectrophoretic concentration enrichment of silica nanoparticles (∼50 nm) and streptavidin protein biomolecules (∼5 nm). We envision the application of these methodologies toward nanofabrication, optofluidics, biomarker discovery, and early disease diagnostics. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A microwave plasma torch and its applications
NASA Astrophysics Data System (ADS)
Uhm, H. S.; Hong, Y. C.; Shin, D. H.
2006-05-01
A portable microwave plasma torch at atmospheric pressure by making use of magnetrons operated at 2.45 GHz and used in a home microwave oven has been developed. This electrodeless torch can be used in various areas including commercial, environmental and military applications. For example, perfluorocompounds (PFCs), which have long lifetimes and serious global warming implications, are widely used during plasma etching and plasma-assisted chamber cleaning processes in chemical vapour deposition systems. The microwave torch effectively eliminates PFCs. Efficient decomposition of toluene gas indicates the effectiveness of volatile organic compound eliminations from industrial emission and the elimination of airborne chemical and biological warfare agents. The microwave torch has been used to synthesize carbon nanotubes in an on-line system, thereby providing the opportunity of mass production of the nanotubes. There are other applications of the microwave plasma torch.
Rapid detection of Mycobacterium tuberculosis complex in sputum Samples using PURE TB-LAMP assay.
N'guessan, K; Horo, K; Coulibaly, I; Adegbele, J; Kouame-Adjei, N; Seck-Angu, H; Guei, A; Kouakou, J; Dosso, M
2016-12-01
Lack of rapid and accurate diagnostic testing is a critical obstacle to global tuberculosis (TB) control. Sensitivity of sputum smear microscopy (SSM) is not optimal; however, it remains the most prevalent tool for TB confirmation in poor countries. As a part of passive case finding of TB detection, this study was conducted to determine the clinical performance of PURE TB-LAMP assay using liquid culture medium as the gold standard. Centre Antituberculeux de Yopougon is one of the 17 intermediate Tuberculosis centers in Côte d'Ivoire. A standardized questionnaire was submitted to patients with signs and symptoms consistent with tuberculosis by a trained caregiver. After obtaining signed consent forms, sputum samples were collected according to National TB Control Programme guidelines (spot-morning). SSM after Ziehl-Neelsen staining and TB-LAMP assay were blindly performed on the first sample. Samples transported to Institut Pasteur de Côte d'Ivoire were decontaminated according to the N-acetyl-L-Cystein method. In Mycobacteria Growth Indicator Tube (MGIT), 500mL of pellets were inoculated and incubated in the MGIT 960 system. MPT64 antigen was detected in positive cultures. Of the 500 patients enrolled, 469 (232men and 239 women) patients were included. The mean ages of men and women were 36.9 (15-86) and 37.3 (15-37.3) years, respectively. There were 56 (12.2%) HIV-infected patients, including 14 women. Clinical isolates of M. tuberculosis complex were detected for 157 (33.5%) patients. Compared with culturing, the overall sensitivity and specificity of SSM were 86% (95% confidence interval [CI]=81-91) and 96% (95% CI=94-98), respectively. The overall sensitivity and specificity for TB-LAMP was 92% (95% CI=0.88-0.96) and 94% (95% CI=0.91-0.97), respectively. Positive likelihood ratios for TB-LAMP and SSM were 15.3 and 21.5, respectively, and negative likelihood ratios for TB-LAMP and SSM were 0.09 and 0.15, respectively. Among the 469 patients, active tuberculosis was detected using TB-LAMP assay and SSM in 162 (34.5%) and 147 (31.3%) patients, respectively. For accurate diagnostic of pulmonary TB, TB-LAMP could be used as a tool of the first intention. Copyright © 2016.
Furuta, Akiko; Kikuchi, Hisae; Fujita, Hiromi; Yamada, Daisuke; Fujiwara, Yuuki; Kabuta, Tomohiro; Nishino, Ichizo; Wada, Keiji; Uchiyama, Yasuo
2015-06-01
Lysosome-associated membrane protein-2 (LAMP-2) is the gene responsible for Danon disease, which is characterized by cardiomyopathy, autophagic vacuolar myopathy, and variable mental retardation. To elucidate the function of LAMP-2 in the central nervous system, we investigated the neuropathological changes in Lamp-2-deficient mice. Immunohistochemical observations revealed that Lamp-1 and cathepsin D-positive lysosomal structures increased in the large neurons of the mouse brain. Ubiquitin-immunoreactive aggregates and concanavalin A-positive materials were detected in these neurons. By means of ultrastructural studies, we found various-shaped accumulations, including lipofuscin, glycolipid-like materials, and membranous structures, in the neurons and glial cells of Lamp-2-deficient brains. In deficient mice, glycogen granules accumulated in hepatocyte lysosomes but were not observed in neurons. These pathological features indicate lysosomal storage disease; however, the findings are unlikely a consequence of deficiency of a single lysosomal enzyme. Although previous study results have shown a large amount of autophagic vacuoles in parenchymal cells of the visceral organs, these findings were rarely detected in the brain tissue except for some axons in the substantia nigra, in which abundant activated microglial cells with increased lipid peroxidation were observed. Thus, LAMP-2 in the central nervous system has a possible role in the degradation of the various macromolecules in lysosomes and an additional function concerning protection from oxidative stress, especially in the substantia nigra. Copyright © 2015 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Variable-Size Bead Layer as Standard Reference for Endothelial Microscopes.
Tufo, Simona; Prazzoli, Erica; Ferraro, Lorenzo; Cozza, Federica; Borghesi, Alessandro; Tavazzi, Silvia
2017-02-01
For morphometric analysis of the cell mosaic of corneal endothelium, checking accuracy and precision of instrumentation is a key step. In this study, a standard reference sample is proposed, developed to reproduce the cornea with its shape and the endothelium with its intrinsic variability in the cell size. A polystyrene bead layer (representing the endothelium) was deposited on a lens (representing the cornea). Bead diameters were 20, 25, and 30 μm (fractions in number 55%, 30%, and 15%, respectively). Bead density and hexagonality were simulated to obtain the expected true values and measured using a slit-lamp endothelial microscope applied to 1) a Takagi 700GL slit lamp at 40× magnification (recommended standard setup) and 2) a Takagi 2ZL slit lamp at 25× magnification. The simulation provided the expected bead density 2001 mm and hexagonality 47%. At 40×, density and hexagonality were measured to be 2009 mm (SD 93 mm) and 45% (SD 3%). At 25× on a different slit lamp, the comparison between measured and expected densities provided the factor 1.526 to resize the image and to use the current algorithms of the slit-lamp endothelial microscope for cell recognition. A variable-size polystyrene bead layer on a lens is proposed as a standard sample mimicking the real shape of the cornea and the variability of cell size and cell arrangement of corneal endothelium. The sample is suggested to evaluate accuracy and precision of cell density and hexagonality obtained by different endothelial microscopes, including a slit-lamp endothelial microscope applied to different slit lamps, also at different magnifications.
T, Sathish Kumar; A, Navaneeth Krishnan; J, Joseph Sahaya Rajan; M, Makesh; K P, Jithendran; S V, Alavandi; K K, Vijayan
2018-05-01
The emerging microsporidian parasite Enterocytozoon hepatopenaei (EHP), the causative agent of hepatopancreatic microsporidiosis, has been widely reported in shrimp-farming countries. EHP infection can be detected by light microscopy observation of spores (1.7 × 1 μm) in stained hepatopancreas (HP) tissue smears, HP tissue sections, and fecal samples. EHP can also be detected by polymerase chain reaction (PCR) targeting the small subunit (SSU) ribosomal RNA (rRNA) gene or the spore wall protein gene (SWP). In this study, a rapid, sensitive, specific, and closed tube visual loop-mediated isothermal amplification (LAMP) protocol combined with FTA cards was developed for the diagnosis of EHP. LAMP primers were designed based on the SSU rRNA gene of EHP. The target sequence of EHP was amplified at constant temperature of 65 °C for 45 min and amplified LAMP products were visually detected in a closed tube system by using SYBR™ green I dye. Detection limit of this LAMP protocol was ten copies. Field and clinical applicability of this assay was evaluated using 162 field samples including 106 HP tissue samples and 56 fecal samples collected from shrimp farms. Out of 162 samples, EHP could be detected in 62 samples (47 HP samples and 15 fecal samples). When compared with SWP-PCR as the gold standard, this EHP LAMP assay had 95.31% sensitivity, 98.98% specificity, and a kappa value of 0.948. This simple, closed tube, clinically evaluated visual LAMP assay has great potential for diagnosing EHP at the farm level, particularly under low-resource circumstances.
Shirato, Kazuya; Semba, Shohei; El-Kafrawy, Sherif A; Hassan, Ahmed M; Tolah, Ahmed M; Takayama, Ikuyo; Kageyama, Tsutomu; Notomi, Tsugunori; Kamitani, Wataru; Matsuyama, Shutoku; Azhar, Esam Ibraheem
2018-05-12
Clinical detection of Middle East respiratory syndrome (MERS) coronavirus (MERS-CoV) in patients is achieved using genetic diagnostic methods, such as real-time RT-PCR assay. Previously, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay for the detection of MERS-CoV [Virol J. 2014. 11:139]. Generally, amplification of RT-LAMP is monitored by the turbidity induced by precipitation of magnesium pyrophosphate with newly synthesized DNA. However, this mechanism cannot completely exclude the possibility of unexpected reactions. Therefore, in this study, fluorescent RT-LAMP assays using quenching probes (QProbes) were developed specifically to monitor only primer-derived signals. Two primer sets (targeting nucleocapsid and ORF1a sequences) were constructed to confirm MERS cases by RT-LAMP assay only. Our data indicate that both primer sets were capable of detecting MERS-CoV RNA to the same level as existing genetic diagnostic methods, and that both were highly specific with no cross-reactivity observed with other respiratory viruses. These primer sets were highly efficient in amplifying target sequences derived from different MERS-CoV strains, including camel MERS-CoV. In addition, the detection efficacy of QProbe RT-LAMP was comparable to that of real-time RT-PCR assay using clinical specimens from patients in Saudi Arabia. Altogether, these results indicate that QProbe RT-LAMP assays described here can be used as powerful diagnostic tools for rapid detection and surveillance of MERS-CoV infections. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Evaluation of the RT-LAMP and LAMP methods for detection of Mycobacterium tuberculosis.
Wu, Dandan; Kang, Jiwen; Li, Baosheng; Sun, Dianxing
2018-05-01
The current methods for detecting Mycobacterium tuberculosis (Mtb) are not clinically optimal. Standard culture methods (SCMs) are slow, costly, or unreliable, and loop-mediated isothermal amplification (LAMP) cannot differentiate live Mtb. This study compared reverse transcription (RT)-LAMP, LAMP, and an SCM for detecting Mtb. A first experiment tested the sensitivity and specificity of primers for 9 species of Mycobacterium (H37Rv, M. intracellulare, M. marinum, M. kansasii, M. avium, M. flavescens, M. smegmatis, M. fortuitum, and M. chelonae); and 3 non-Mycobacterium species (Staphylococcus aureus, Pseudomonas aeruginosa, and Klebsiella pneumoniae). A second experiment tested sputum specimens for the presence of Mtb, from 100 patients with tuberculosis (clinical) and 22 from patients without tuberculosis (control), using Roche solid culture (SCM), LAMP, and RT-LAMP. In the clinical samples. The rates of positivity for Mtb of the SCM, LAMP, and RT-LAMP methods were 88%, 92%, and 100%, respectively. The difference in detection rate was significant between RT-LAMP and SCM, but RT-LAMP and LAMP were comparable. In the control group, the detection rates were nil for all three methods. The specificities of the methods were similar. The sensitivity of RT-LAMP was ~10-fold higher than that of LAMP for detecting Mtb. Unlike LAMP, RT-LAMP could identify viable bacteria, and was able to detect a single copy of Mtb. Among SCM, LAMP, and RT-LAMP, the latter is the most suitable for wide use in the lower-level hospitals and clinics of China for detecting Mtb in sputum samples. © 2017 Wiley Periodicals, Inc.
Replacement policy of residential lighting optimized for cost, energy, and greenhouse gas emissions
NASA Astrophysics Data System (ADS)
Liu, Lixi; Keoleian, Gregory A.; Saitou, Kazuhiro
2017-11-01
Accounting for 10% of the electricity consumption in the US, artificial lighting represents one of the easiest ways to cut household energy bills and greenhouse gas (GHG) emissions by upgrading to energy-efficient technologies such as compact fluorescent lamps (CFL) and light emitting diodes (LED). However, given the high initial cost and rapidly improving trajectory of solid-state lighting today, estimating the right time to switch over to LEDs from a cost, primary energy, and GHG emissions perspective is not a straightforward problem. This is an optimal replacement problem that depends on many determinants, including how often the lamp is used, the state of the initial lamp, and the trajectories of lighting technology and of electricity generation. In this paper, multiple replacement scenarios of a 60 watt-equivalent A19 lamp are analyzed and for each scenario, a few replacement policies are recommended. For example, at an average use of 3 hr day-1 (US average), it may be optimal both economically and energetically to delay the adoption of LEDs until 2020 with the use of CFLs, whereas purchasing LEDs today may be optimal in terms of GHG emissions. In contrast, incandescent and halogen lamps should be replaced immediately. Based on expected LED improvement, upgrading LED lamps before the end of their rated lifetime may provide cost and environmental savings over time by taking advantage of the higher energy efficiency of newer models.
Vaikkinen, Anu; Haapala, Markus; Kersten, Hendrik; Benter, Thorsten; Kostiainen, Risto; Kauppila, Tiina J
2012-02-07
A direct current induced vacuum ultraviolet (dc-VUV) krypton discharge lamp and an alternating current, radio frequency (rf) induced VUV lamp that are essentially similar to lamps in commercial atmospheric pressure photoionization (APPI) ion sources were compared. The emission distributions along the diameter of the lamp exit window were measured, and they showed that the beam of the rf lamp is much wider than that of the dc lamp. Thus, the rf lamp has larger efficient ionization area, and it also emits more photons than the dc lamp. The ionization efficiencies of the lamps were compared using identical spray geometries with both lamps in microchip APPI mass spectrometry (μAPPI-MS) and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS). A comprehensive view on the ionization was gained by studying six different μAPPI solvent compositions, five DAPPI spray solvents, and completely solvent-free DAPPI. The observed reactant ions for each solvent composition were very similar with both lamps except for toluene, which showed a higher amount of solvent originating oxidation products with the rf lamp than with the dc lamp in μAPPI. Moreover, the same analyte ions were detected with both lamps, and thus, the ionization mechanisms with both lamps are similar. The rf lamp showed a higher ionization efficiency than the dc lamp in all experiments. The difference between the lamp ionization efficiencies was greatest when high ionization energy (IE) solvent compositions (IEs above 10 eV), i.e., hexane, methanol, and methanol/water, (1:1 v:v) were used. The higher ionization efficiency of the rf lamp is likely due to the larger area of high intensity light emission, and the resulting larger efficient ionization area and higher amount of photons emitted. These result in higher solvent reactant ion production, which in turn enables more efficient analyte ion production. © 2012 American Chemical Society
KINOSHITA, Yuta; NIWA, Hidekazu; KATAYAMA, Yoshinari; HARIU, Kazuhisa
2015-01-01
ABSTRACT Taylorella equigenitalis is a causative bacterium of contagious equine metritis (CEM), and Taylorella asinigenitalis is species belonging to genus Taylorella. The authors developed two loop-mediated isothermal amplification (LAMP) methods, Te-LAMP and Ta-LAMP, for detecting T. equigenitalis and T. asinigenitalis, respectively. Using experimentally spiked samples, Te-LAMP was as sensitive as a published semi-nested PCR method, and Ta-LAMP was more sensitive than conventional PCR. Multiplex LAMP worked well without nonspecific reactions, and the analytical sensitivities of multiplex LAMP in the spiked samples were almost equivalent to those of Te-LAMP and Ta-LAMP. Therefore, the LAMP methods are considered useful tools to detect T. equigenitalis and/or T. asinigenitalis, and preventive measures will be rapidly implemented if the occurrence of CEM is confirmed by the LAMP methods. PMID:25829868
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lall, Pradeep; Sakalaukus, Peter; Davis, Lynn
2015-07-06
Today’s lighting technology is steadily becoming more energy efficient and less toxic to the environment since the passing of the Energy Independence and Security Act of 2007 (EISA) [1]. EISA has mandated a higher energy efficiency standard for lighting products and the phase out of the common incandescent lamp. This has led lighting manufacturers to pursue solid-state lighting (SSL) technologies for consumer lighting applications. However, two major roadblocks are hindering the transition process to SSL lamps: cost and quality. In order to cut cost, manufactures are moving towards cheaper packaging materials and a variety of package architecture construction techniques whichmore » may potentially erode the quality of the lamp and reduce its survivability in everyday applications. Typically, SSL lamps are given product lifetimes of over twenty years based off of the IES TM-21-11 lighting standard which does not include moisture effects or large operational temperatures [2]. A group of recently released off-the-shelf lamps have undergone a steady-state temperature humidity bias life test of 85°C/85%RH (85/85) to investigate the reliability in harsh environment applications. The lack of accelerated test methods for lamps to assess reliability prior to introduction into the marketplace does not exist in literature. There is a need for SSL physics based models for the assessment and prediction of a lamp’s lifetime which is being spearheaded by the DOE [3]. In order to be fully accepted in the marketplace, SSL lamps must be able to perform similarly to incandescent lamps in these environments, as well as live up to the lifetime claims of manufacturers. A lamp’s package architecture must be designed with performance factors in mind, as well as address some of the known and published package related failure mechanisms, such as carbonization of the encapsulant material, delamination, encapsulant yellowing, lens cracking, and phosphor thermal quenching [4]. Each failure mechanism produces the similar failure mode of lumen degradation predominately due to two contributing factors: high junction temperature and moisture ingress. The current state-of-the-art has focused on individual areas of the lamp, such as the LED chip, substrate material, electrical driver design and thermal management techniques. [5] – [16] Looking at the lamp as a whole is a novel approach and has not been seen before in literature. This work followed the JEDEC standard JESD22-A101C of 85/85 with a one hour interval of applied voltage followed by a one hour interval of no applied voltage [17]. This test was performed continuously for each SSL lamp until it became nonoperational, i.e. did not turn on. Periodically, photometric measurements were taken following the IES LM-79-08 standard at room temperature using an integrating sphere, a spectrometer, and lighting software. The overall health of the SSL lamps was assed using the relative luminous flux (RLF), correlated color temperature (CCT) and the color difference (Δu'v') using the Euclidean distance of the CIE 1976 color space coordinates. Finally, a Weibull analysis was completed to compare the characteristic lifetime of the SSL lamp to the actual rated lifetime. An important result from this work shows that the rated lifetime does not come close to the actual lifetime when the SSL lamps are used in a harsh humid environment which is fairly common in outdoor applications across the U.S. Also, the photometric results are presented for the entire lifetime of each SSL lamp under test.« less
2016-01-01
Ultraviolet light emitting diodes (UV LEDs) have become widespread in chemical research as highly efficient light sources for photochemistry and photopolymerization. However, in more complex experimental setups requiring highly concentrated light and highly spatially resolved patterning of the light, high-pressure mercury arc lamps are still widely used because they emit intense UV light from a compact arc volume that can be efficiently coupled into optical systems. Advances in the deposition and p-type doping of gallium nitride have recently permitted the manufacture of UV LEDs capable of replacing mercury arc lamps also in these applications. These UV LEDs exceed the spectral radiance of mercury lamps even at the intense I-line at 365 nm. Here we present the successful exchange of a high-pressure mercury arc lamp for a new generation UV LED as a light source in photolithographic chemistry and its use in the fabrication of high-density DNA microarrays. We show that the improved light radiance and efficiency of these LEDs offer substantial practical, economic and ecological advantages, including faster synthesis, lower hardware costs, very long lifetime, an >85-fold reduction in electricity consumption and the elimination of mercury waste and contamination. PMID:28066690
Hölz, K; Lietard, J; Somoza, M M
2017-01-03
Ultraviolet light emitting diodes (UV LEDs) have become widespread in chemical research as highly efficient light sources for photochemistry and photopolymerization. However, in more complex experimental setups requiring highly concentrated light and highly spatially resolved patterning of the light, high-pressure mercury arc lamps are still widely used because they emit intense UV light from a compact arc volume that can be efficiently coupled into optical systems. Advances in the deposition and p -type doping of gallium nitride have recently permitted the manufacture of UV LEDs capable of replacing mercury arc lamps also in these applications. These UV LEDs exceed the spectral radiance of mercury lamps even at the intense I-line at 365 nm. Here we present the successful exchange of a high-pressure mercury arc lamp for a new generation UV LED as a light source in photolithographic chemistry and its use in the fabrication of high-density DNA microarrays. We show that the improved light radiance and efficiency of these LEDs offer substantial practical, economic and ecological advantages, including faster synthesis, lower hardware costs, very long lifetime, an >85-fold reduction in electricity consumption and the elimination of mercury waste and contamination.
Lee, DoKyung; Kim, Eun Jin; Kilgore, Paul E.; Takahashi, Hideyuki; Ohnishi, Makoto; Tomono, Jun; Miyamoto, Shigehiko; Omagari, Daisuke; Kim, Dong Wook; Seki, Mitsuko
2016-01-01
We have developed a novel Neisseria meningitidis serogroup-specific loop-mediated isothermal amplification (LAMP) assay for six of the most common meningococcal serogroups (A, B, C, W, X, and Y). The assay was evaluated using a set of 31 meningococcal LAMP assay positive cerebrospinal fluid (CSF) specimens from 1574 children with suspected meningitis identified in prospective surveillance between 1998 and 2002 in Vietnam, China, and Korea. Primer specificity was validated using 15 N. meningitidis strains (including serogroups A, B, C, E, W, X, Y, and Z) and 19 non-N. meningitidis species. The N. meningitidis serogroup LAMP detected down to ten copies and 100 colony-forming units per reaction. Twenty-nine CSF had N. meningitidis serogroup identified by LAMP compared with two CSF in which N. meningitidis serogroup was identified by culture and multi-locus sequence typing. This is the first report of a serogroup-specific identification assay for N. meningitidis using the LAMP method. Our results suggest that this assay will be a rapid, sensitive, and uniquely serogroup-specific assay with potential for application in clinical laboratories and public health surveillance systems. PMID:26793181
Identification of Pseudallescheria and Scedosporium species by three molecular methods.
Lu, Qiaoyun; Gerrits van den Ende, A H G; Bakkers, J M J E; Sun, Jiufeng; Lackner, M; Najafzadeh, M J; Melchers, W J G; Li, Ruoyu; de Hoog, G S
2011-03-01
The major clinically relevant species in Scedosporium (teleomorph Pseudallescheria) are Pseudallescheria boydii, Scedosporium aurantiacum, Scedosporium apiospermum, and Scedosporium prolificans, while Pseudallescheria minutispora, Petriellopsis desertorum, and Scedosporium dehoogii are exceptional agents of disease. Three molecular methods targeting the partial β-tubulin gene were developed and evaluated to identify six closely related species of the S. apiospermum complex using quantitative real-time PCR (qPCR), PCR-based reverse line blot (PCR-RLB), and loop-mediated isothermal amplification (LAMP). qPCR was not specific enough for the identification of all species but had the highest sensitivity. The PCR-RLB assay was efficient for the identification of five species. LAMP distinguished all six species unambiguously. The analytical sensitivities of qPCR, PCR-RLB, and LAMP combined with MagNAPure, CTAB (cetyltrimethylammonium bromide), and FTA filter (Whatman) extraction were 50, 5 × 10(3), and 5 × 10(2) cells/μl, respectively. When LAMP was combined with a simplified DNA extraction method using an FTA filter, identification to the species level was achieved within 2 h, including DNA extraction. The FTA-LAMP assay is therefore recommended as a cost-effective, simple, and rapid method for the identification of Scedosporium species.
Identification of Pseudallescheria and Scedosporium Species by Three Molecular Methods▿
Lu, Qiaoyun; Gerrits van den Ende, A. H. G.; Bakkers, J. M. J. E.; Sun, Jiufeng; Lackner, M.; Najafzadeh, M. J.; Melchers, W. J. G.; Li, Ruoyu; de Hoog, G. S.
2011-01-01
The major clinically relevant species in Scedosporium (teleomorph Pseudallescheria) are Pseudallescheria boydii, Scedosporium aurantiacum, Scedosporium apiospermum, and Scedosporium prolificans, while Pseudallescheria minutispora, Petriellopsis desertorum, and Scedosporium dehoogii are exceptional agents of disease. Three molecular methods targeting the partial β-tubulin gene were developed and evaluated to identify six closely related species of the S. apiospermum complex using quantitative real-time PCR (qPCR), PCR-based reverse line blot (PCR-RLB), and loop-mediated isothermal amplification (LAMP). qPCR was not specific enough for the identification of all species but had the highest sensitivity. The PCR-RLB assay was efficient for the identification of five species. LAMP distinguished all six species unambiguously. The analytical sensitivities of qPCR, PCR-RLB, and LAMP combined with MagNAPure, CTAB (cetyltrimethylammonium bromide), and FTA filter (Whatman) extraction were 50, 5 × 103, and 5 × 102 cells/μl, respectively. When LAMP was combined with a simplified DNA extraction method using an FTA filter, identification to the species level was achieved within 2 h, including DNA extraction. The FTA-LAMP assay is therefore recommended as a cost-effective, simple, and rapid method for the identification of Scedosporium species. PMID:21177887
Mareninova, Olga A; Sendler, Matthias; Malla, Sudarshan Ravi; Yakubov, Iskandar; French, Samuel W; Tokhtaeva, Elmira; Vagin, Olga; Oorschot, Viola; Lüllmann-Rauch, Renate; Blanz, Judith; Dawson, David; Klumperman, Judith; Lerch, Markus M; Mayerle, Julia; Gukovsky, Ilya; Gukovskaya, Anna S
2015-11-01
The pathogenic mechanism of pancreatitis is poorly understood. Recent evidence implicates defective autophagy in pancreatitis responses; however, the pathways mediating impaired autophagy in pancreas remain largely unknown. Here, we investigate the role of lysosome associated membrane proteins (LAMPs) in pancreatitis. We analyzed changes in LAMPs in experimental models and human pancreatitis, and the underlying mechanisms: LAMP de-glycosylation and degradation. LAMP cleavage by cathepsin B (CatB) was analyzed by mass spectrometry. We used mice deficient in LAMP-2 to assess its role in pancreatitis. Pancreatic levels of LAMP-1 and LAMP-2 greatly decrease across various pancreatitis models and in human disease. Pancreatitis does not trigger LAMPs' bulk de-glycosylation, but induces their degradation via CatB-mediated cleavage of LAMP molecule close to the boundary between luminal and transmembrane domains. LAMP-2 null mice spontaneously develop pancreatitis that begins with acinar cell vacuolization due to impaired autophagic flux, and progresses to severe pancreas damage characterized by trypsinogen activation, macrophage-driven inflammation, and acinar cell death. LAMP-2 deficiency causes a decrease in pancreatic digestive enzymes content, stimulates the basal and inhibits CCK-induced amylase secretion by acinar cells. The effects of LAMP-2 knockout and acute cerulein pancreatitis overlap, which corroborates the pathogenic role of LAMP decrease in experimental pancreatitis models. The results indicate a critical role for LAMPs, particularly LAMP-2, in maintaining pancreatic acinar cell homeostasis, and provide evidence that defective lysosomal function, resulting in impaired autophagy, leads to pancreatitis. Mice with LAMP-2 deficiency present a novel genetic model of human pancreatitis caused by lysosomal/autophagic dysfunction.
Neutral gas and diffuse interstellar bands in the LMC
NASA Technical Reports Server (NTRS)
Danks, Anthony C.; Penprase, Brian
1994-01-01
Tracing the dynamics of the neutral gas and observing diffuse interstellar bands in the LMC (Large Magellanic Cloud) was the focus of this study. The S/N values, a Quartz lamp exposure, a T horium Argon Comparision lamp exposure, and spectral plots for each star observed were taken. The stars observed were selected to sample the 30 Dor vicinty. NaI absorption profiles are included.
CALiPER Report 20.3: Robustness of LED PAR38 Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2014-12-30
A small sample of each of the CALiPER Application Summary Report 20 PAR38 lamp types underwent stress testing that included substantial temperature and humidity changes, electrical variation, and vibration. The results do not directly address expected lifetime, but can be compared with one another, as well as with benchmark conventional products, to assess the relative robustness of the product designs.
Dispenser printed electroluminescent lamps on textiles for smart fabric applications
NASA Astrophysics Data System (ADS)
de Vos, Marc; Torah, Russel; Tudor, John
2016-04-01
Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.
49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.
Code of Federal Regulations, 2010 CFR
2010-10-01
... this paragraph. (b) Auxiliary driving lamps and front fog lamps. Commercial motor vehicles may be... Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective...
49 CFR 393.11 - Lamps and reflective devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Lamps and reflective devices. 393.11 Section 393... ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.11 Lamps and reflective devices. (a)(1) Lamps and reflex reflectors. Table 1 specifies the requirements for lamps...
10 CFR 429.40 - Candelabra base incandescent lamps and intermediate base incandescent lamps.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Candelabra base incandescent lamps and intermediate base incandescent lamps. 429.40 Section 429.40 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION....40 Candelabra base incandescent lamps and intermediate base incandescent lamps. (a) Sampling plan for...
49 CFR 393.11 - Lamps and reflective devices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Lamps and reflective devices. 393.11 Section 393... ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.11 Lamps and reflective devices. (a)(1) Lamps and reflex reflectors. Table 1 specifies the requirements for lamps...
Pérez, Liliana; McLetchie, Shawna; Gardiner, Gail J; Deffit, Sarah N; Zhou, Delu; Blum, Janice S
2016-03-15
Cells use multiple autophagy pathways to sequester macromolecules, senescent organelles, and pathogens. Several conserved isoforms of the lysosome-associated membrane protein-2 (LAMP-2) regulate these pathways influencing immune recognition and responses. LAMP-2A is required for chaperone-mediated autophagy (CMA), which promotes Ag capture and MHC class II (MHCII) presentation in B cells and signaling in T cells. LAMP-2B regulates lysosome maturation to impact macroautophagy and phagocytosis. Yet, far less is known about LAMP-2C function. Whereas LAMP2A and LAMP2B mRNA were broadly detected in human tissues, LAMP2C expression was more limited. Transcripts for the three LAMP2 isoforms increased with B cell activation, although specific gene induction varied depending on TLR versus BCR engagement. To examine LAMP-2C function in human B cells and specifically its role in Ag presentation, we used ectopic gene expression. Increased LAMP-2C expression in B cells did not alter MHCII expression or invariant chain processing, but did perturb cytoplasmic Ag presentation via CMA. MHCII presentation of epitopes from exogenous and membrane Ags was not affected by LAMP-2C expression in B cells. Similarly, changes in B cell LAMP-2C expression did not impact macroautophagy. The gene expression of other LAMP2 isoforms and proteasome and lysosomal proteases activities were unperturbed by LAMP-2C ectopic expression. LAMP-2C levels modulated the steady-state expression of several cytoplasmic proteins that are targeted for degradation by CMA and diminished peptide translocation via this pathway. Thus, LAMP-2C serves as a natural inhibitor of CMA that can selectively skew MHCII presentation of cytoplasmic Ags. Copyright © 2016 by The American Association of Immunologists, Inc.
Pérez, Liliana; McLetchie, Shawna; Gardiner, Gail J.; Deffit, Sarah N.; Zhou, Delu; Blum, Janice S.
2016-01-01
Cells utilize multiple autophagy pathways to sequester macromolecules, senescent organelles, and pathogens. Several conserved isoforms of the lysosome-associated membrane protein (LAMP)-2 regulate these pathways influencing immune recognition and responses. LAMP-2A is required for chaperone-mediated autophagy (CMA) which promotes Ag capture and MHC class II (MHCII) presentation in B cells and signaling in T cells. LAMP-2B regulates lysosome maturation to impact macroautophagy (MA) and phagocytosis. Yet, far less is known about LAMP-2C function. While LAMP2A and LAMP2B mRNA were broadly detected in human tissues, LAMP2C expression was more limited. Transcripts for the three LAMP2 isoforms increased with B cell activation, although specific gene induction varied depending on TLR versus BCR engagement. To examine LAMP-2C function in human B cells and specifically its role in Ag presentation, ectopic gene expression was used. Increased LAMP-2C expression in B cells did not alter MHCII expression or invariant chain processing, but did perturb cytoplasmic Ag presentation via CMA. MHCII presentation of epitopes from exogenous and membrane Ags was not affected by LAMP-2C expression in B cells. Similarly, changes in B cell LAMP-2C expression did not impact MA. The gene expression of other LAMP2 isoforms as well as the proteasome and lysosomal proteases activities were unperturbed by LAMP-2C ectopic expression. LAMP-2C levels modulated the steady-state expression of several cytoplasmic proteins which are targeted for degradation by CMA and diminished peptide translocation via this pathway. Thus, LAMP-2C serves as a natural inhibitor of CMA which can selectively skew MHCII presentation of cytoplasmic Ags. PMID:26856698
Ni, Xing-Wei; McManus, Donald P.; Lou, Zhong-Zi; Yang, Ji-Fei; Yan, Hong-Bin; Li, Li; Li, Hong-Min; Liu, Quan-Yuan; Li, Chun-Hua; Shi, Wan-Gui; Fan, Yan-Lei; Liu, Xu; Cai, Jin-Zhong; Lei, Meng-Tong; Fu, Bao-Quan; Yang, Yu-Rong; Jia, Wan-Zhong
2014-01-01
Background Cystic echinococcosis is highly prevalent in northwest China. A cost-effective, easy to operate diagnostic tool with high sensitivity and specificity would greatly facilitate the monitoring of Echinococcus infections in canine definitive hosts. Methods The primers used in the LAMP assay were based on the mitochondrial nad5 gene of E. granulosus sensu stricto (E. granulosus s.s., or E.g.s.s.) and were designed using Primer Explorer V4 software. The developed LAMP assay was compared with a conventional PCR method, copro-ELISA and microscopy, using the faeces of dogs experimentally infected with E.g.s.s., and field-collected faeces of domestic dogs including 190 from Qinghai province highly endemic for E.g.s.s. and 30 controls from an area in Gansu, where a domestic dog de-worming program was in operation. Results The positivity rates obtained for the field-collected faecal samples were 12.6%, 1.6% and 2.1% by the LAMP, PCR and copro-ELISA assays, respectively. All samples obtained from the control dogs were negative. Compared with the conventional PCR, the LAMP assay provided 88.8% specificity and 100% sensitivity. The higher sensitivity of the LAMP method was also shown by the fact that it could detect the presence of laboratory challenge dog infections of E. granulsous s.s. four days earlier than the PCR method. Three copro-samples shown positive by the commercial copro-ELISA were all negative by LAMP, PCR and microscopy, which suggests these samples may have originated from another infection rather than E. granulsous s.s., possibly E. shiquicus or E. Canadensis, which is also present in China. Conclusions We have developed a potentially useful surveillance tool for determining the prevalence of canine E. granulosus s.s. infections in the field. The LAMP assay may lead to a more cost-effective and practicable way of tracking Echinococcus infections in canids, especially when combined with the copro-ELISA. PMID:25007051
High dynamic range electric field sensor for electromagnetic pulse detection.
Lin, Che-Yun; Wang, Alan X; Lee, Beom Suk; Zhang, Xingyu; Chen, Ray T
2011-08-29
We design a high dynamic range electric field sensor based on domain inverted electro-optic (E-O) polymer Y-fed directional coupler for electromagnetic wave detection. This electrode-less, all optical, wideband electrical field sensor is fabricated using standard processing for E-O polymer photonic devices. Experimental results demonstrate effective detection of electric field from 16.7V/m to 750KV/m at a frequency of 1GHz, and spurious free measurement range of 70dB.
Ponce, Camille; Kaczorowski, Flora; Perpoint, Thomas; Miailhes, Patrick; Sigal, Alain; Javouhey, Etienne; Gillet, Yves; Jacquin, Laurent; Douplat, Marion; Tazarourte, Karim; Potinet, Véronique; Simon, Bruno; Lavoignat, Adeline; Bonnot, Guillaume; Sow, Fatimata; Bienvenu, Anne-Lise; Picot, Stéphane
2017-01-01
Background: Sensitive and easy-to-perform methods for the diagnosis of malaria are not yet available. Improving the limit of detection and following the requirements for certification are issues to be addressed in both endemic and non-endemic settings. The aim of this study was to test whether loop-mediated isothermal amplification of DNA (LAMP) may be an alternative to microscopy or real-time PCR for the screening of imported malaria cases in non-endemic area. Results: 310 blood samples associated with 829 suspected cases of imported malaria were tested during a one year period. Microscopy (thin and thick stained blood slides, reference standard) was used for the diagnosis. Real-time PCR was used as a standard of truth, and LAMP (Meridian Malaria Plus) was used as an index test in a prospective study conducted following the Standards for Reporting Diagnosis Accuracy Studies. In the 83 positive samples, species identification was P. falciparum (n = 66), P. ovale (n = 9), P. vivax (n = 3) P. malariae (n = 3) and 2 co-infections with P. falciparum + P.malariae. Using LAMP methods, 93 samples gave positive results, including 4 false-positives. Sensitivity, specificity, positive predictive value and negative predictive value for LAMP tests were 100%, 98.13%, 95.51%, and 100% compared to PCR. Conclusion: High negative predictive value, and limit of detection suggest that LAMP can be used for screening of imported malaria cases in non-endemic countries when expert microscopists are not immediately available. However, the rare occurrence of non-valid results and the need for species identification and quantification of positive samples preclude the use of LAMP as a single reference method. PMID:29251261
49 CFR 393.22 - Combination of lighting devices and reflectors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical...) Prohibited combinations. (1) A turn signal lamp must not be combined optically with either a head lamp or... the turn signal lamp. (2) A turn signal lamp must not be combined optically with a stop lamp unless...
Characterization and recovery of mercury from spent fluorescent lamps.
Jang, Min; Hong, Seung Mo; Park, Jae K
2005-01-01
Fluorescent lamps rely on mercury as the source of ultraviolet radiation for the production of visible light. Partitioning of mercury among vapor phase, loose phosphor powders produced during breaking and washing steps, glass matrices, phosphor powders attached on the glass and aluminum end caps was examined from simulated laboratory lamp recycling tests for different types of spent and new fluorescent lamps. Mercury concentrations in lamp glasses taken from commercial lamp recyclers were also analyzed for comparison with the simulated results of spent and new lamps of different types. The mercury content of the glass from spent lamps was highly variable depending on the lamp type and manufacturer; the median values of the mercury concentration in glasses for spent 26- (T8) and 38-mm (T12) diameter fluorescent lamps were approximately 30 and 45 microg/g, respectively. The average mercury concentration of samples taken from recycler A was 29.6 microg/g, which was about 64% of median value measured from the spent T12 lamps. Over 94% of total mercury in lamps remained either as a component of phosphor powders attached inside the lamp or in glass matrices. New T12 lamps had a higher partitioning percentage of elemental mercury in the vapor phase (0.17%) than spent T12 lamps (0.04%), while spent lamps had higher partitioning percentages of mercury resided on end-caps and phosphor powders detached from the breaking and washing steps. The TCLP values of simulated all lamp-glasses and samples obtained from recyclers were higher than the limit of LDR standard (0.025 mg/L). After investigating acid treatment and high temperature treatment as mercury reclamation techniques, it was found that heating provided the most effective mercury capture. Although the initial mercury concentrations of individual sample were different, the mercury concentrations after 1 h exposure at 100 degrees C were below 4 mug/g for all samples (i.e., <1% remaining). Therefore, it is recommended that heating be used for recovering mercury from spent fluorescent lamps.
Impact of the EISA 2007 Energy Efficiency Standard on General Service Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kantner, Colleen L.S.; Alstone, Andrea L.; Ganeshalingam, Mohan
The Energy Policy and Conservation Act of 1975, as amended by the Energy Independence and Security Act of 2007 (EISA 2007), requires that, effective beginning January 1, 2020, the Secretary of Energy shall prohibit the sale of any general service lamp (GSL) that does not meet a minimum efficacy standard of 45 lumens per watt. This is referred to as the EISA 2007 backstop. The U.S. Department of Energy recently revised the definition of the term GSL to include certain lamps that were either previously excluded or not explicitly mentioned in the EISA 2007 definition. For this subset of GSLs,more » we assess the impacts of the EISA 2007 backstop on national energy consumption, carbon dioxide emissions, and consumer expenditures. To estimate these impacts, we projected the energy use, purchase price, and operating cost of representative lamps purchased during a 30-year analysis period, 2020-2049, for cases in which the EISA 2007 backstop does and does not take effect; the impacts of the backstop are then given by the difference between the two cases. In developing the projection model, we also performed the most comprehensive assessment to date of usage patterns and lifetime distributions for the analyzed lamp types in the United States. There is substantial uncertainty in the estimated impacts, which arises from uncertainty in the speed and extent of the market conversion to solid state lighting technology that would occur in the absence of the EISA 2007 backstop. In our central estimate we find that the EISA 2007 backstop results in significant energy savings of 27 quads and consumer net present value of $120 billion (at a seven percent discount rate) for lamps shipped between 2020 and 2049, and carbon dioxide emissions reduction of 540 million metric tons by 2030 for those GSLs not explicitly included in the EISA 2007 definition of a GSL.« less
Impacts of the EISA 2007 Energy Efficiency Standard on General Service Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kantner, Colleen L.; Alstone, Andrea L.; Ganeshalingam, Mohan
The Energy Policy and Conservation Act of 1975, as amended by the Energy Independence and Security Act of 2007 (EISA 2007), requires that, effective beginning January 1, 2020, the Secretary of Energy shall prohibit the sale of any general service lamp (GSL) that does not meet a minimum efficacy standard of 45 lumens per watt. This is referred to as the EISA 2007 backstop. The U.S. Department of Energy recently revised the definition of the term GSL to include certain lamps that were either previously excluded or not explicitly mentioned in the EISA 2007 definition. For this subset of GSLs,more » we assess the impacts of the EISA 2007 backstop on national energy consumption, carbon dioxide emissions, and consumer expenditures. To estimate these impacts, we projected the energy use, purchase price, and operating cost of representative lamps purchased during a 30-year analysis period, 2020-2049, for cases in which the EISA 2007 backstop does and does not take effect; the impacts of the backstop are then given by the difference between the two cases. In developing the projection model, we also performed the most comprehensive assessment to date of usage patterns and lifetime distributions for the analyzed lamp types in the United States. There is substantial uncertainty in the estimated impacts, which arises from uncertainty in the speed and extent of the market conversion to solid state lighting technology that would occur in the absence of the EISA 2007 backstop. In our central estimate we find that the EISA 2007 backstop results in significant energy savings of 27 quads and consumer net present value of $120 billion (at a seven percent discount rate) for lamps shipped between 2020 and 2049, and carbon dioxide emissions reduction of 540 million metric tons by 2030 for those GSLs not explicitly included in the EISA 2007 definition of a GSL.« less
Chen, M H; Kuo, S T; Renault, T; Chang, P H
2014-02-01
A loop-mediated isothermal amplification (LAMP) assay was developed for the detection of abalone herpesvirus DNA. Two pairs of primers were designed, based on the sequence of the DNA polymerase gene of abalone herpesvirus. The reaction temperature and time were optimized to 63°C and 60min, respectively. LAMP amplicons were analyzed by 2% agarose gel electrophoresis or by visual inspection of a colour change emitted by fluorescent dye. The method developed was specific for the detection of abalone herpesvirus, without cross-reactions with other tested herpesviruses including ostreid herpesvirus 1 (OsHV-1), European eel herpesvirus, koi herpesvirus (KHV) and an avian herpesvirus. The LAMP assay was 100 folds more sensitive than a conventional PCR and 10 folds less sensitive than a SYBR Green PCR. These results indicate that the developed LAMP assay is a simple, rapid, sensitive, specific and reliable technique for the detection of abalone herpesvirus. Copyright © 2013 Elsevier B.V. All rights reserved.
Design method of LED rear fog lamp based on freeform micro-surface reflectors
NASA Astrophysics Data System (ADS)
Yu, Jindong; Wu, Heng
2017-11-01
We propose a practical method for the design of a light-emitting diode (LED) rear fog lamp based on freeform micro-surface reflectors. The lamp consists of nine LEDs and each of them has a freeform micro-surface reflector correspondingly. The micro-surface reflector design includes three steps. An initial freeform reflector is first built based on the light energy maps. The micro-surface reflector is then constructed on the bias of the initial one. Finally, a two-step method is designed to optimize the micro-surface reflector. With the proposed method, a module is designed and LCW DURIS E5 LED source whose emitting surface is 5.7 mm × 3.0 mm is adopted for simulation. A prototype is also assembled and fabricated to verify the real performance. Both the simulation and experimental results demonstrate that the luminous intensity distribution can well fulfill the requirements of ECE No.38 regulation. Furthermore, more than 79% energy can be saved when compared with the rear fog lamps using conventional sources.
The LAMP instrument at the Linac Coherent Light Source free-electron laser
Osipov, Timur; Bostedt, Christoph; Castagna, J. -C.; ...
2018-03-23
The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusivemore » metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here in this paper we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.« less
The LAMP instrument at the Linac Coherent Light Source free-electron laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osipov, Timur; Bostedt, Christoph; Castagna, J. -C.
The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusivemore » metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here in this paper we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.« less
Wang, Yi; Li, Hui; Wang, Yan; Zhang, Lu; Xu, Jianguo; Ye, Changyun
2017-01-01
The report describes a simple, rapid and sensitive assay for visual and multiplex detection of Enterococcus faecalis and Staphylococcus aureus based on multiple loop-mediated isothermal amplification (mLAMP) and lateral flow biosensor (LFB). Detection and differentiation of the Ef0027 gene (E. faecalis-specific gene) and nuc gene (S. aureus-specific gene) were determined using fluorescein (FITC)-and digoxin-modified primers in the mLAMP process. In the presence of biotin- and FITC-/digoxin-modified primers, the mLAMP yielded numerous biotin- and FITC-/digoxin-attached duplex products, which were detected by LFB through biotin/streptavidin interaction (biotin on the duplex and streptavidin on the gold nanoparticle) and immunoreactions (FITC/digoxin on the duplex and anti-FITC/digoxin on the LFB test line). The accumulation of gold nanoparticles generated a characteristic red line, enabling visual and multiplex detection of target pathogens without instrumentation. The limit of detection (LoD), analytical specificity and feasibility of LAMP-LFB technique were successfully examined in pure culture and blood samples. The entire procedure, including specimen (blood samples) processing (30 min), isothermal reaction (40 min) and result reporting (within 2 min), could be completed within 75 min. Thus, this assay offers a simple, rapid, sensitive and specific test for multiplex detection of E. faecalis and S. aureus strains. Furthermore, the LAMP-LFB strategy is a universal technique, which can be extended to detect various target sequences by re-designing the specific LAMP primers. PMID:28239371
RF driven sulfur lamp having driving electrodes arranged to cool the lamp
Gabor, George; Orr, Thomas Robert; Greene, Charles Maurice; Crawford, Douglas Gordon; Berman, Samuel Maurice
1998-01-01
A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance.
Yasuhara-Bell, Jarred; de Silva, Asoka; Heuchelin, Scott A; Chaky, Jennifer L; Alvarez, Anne M
2016-03-01
The Goss's wilt pathogen, Clavibacter michiganensis subsp. nebraskensis, can cause considerable losses in maize (Zea mays) production. Diagnosis of Goss's wilt currently is based on symptomology and identification of C. michiganensis subsp. nebraskensis, following isolation on a semiselective medium and/or serological testing. In an effort to provide a more efficient identification method, a loop-mediated amplification (LAMP) assay was developed to detect the tripartite ATP-independent periplasmic (TRAP)-type C4-dicarboxylate transport system large permease component and tested using strains of C. michiganensis subsp. nebraskensis, all other C. michiganensis subspecies and several genera of nontarget bacteria. Only strains of C. michiganensis subsp. nebraskensis reacted positively with the LAMP assay. The LAMP assay was then used to identify bacterial isolates from diseased maize. 16S rDNA and dnaA sequence analyses were used to confirm the identity of the maize isolates and validate assay specificity. The Cmm ImmunoStrip assay was included as a presumptive identification test of C. michiganensis subsp. nebraskensis at the species level. The Cmn-LAMP assay was further tested using symptomatic leaf tissue. The Cmn-LAMP assay was run in a hand-held real-time monitoring device (SMART-DART) and performed equally to in-lab quantitative polymerase chain reaction equipment. The Cmn-LAMP assay accurately identified C. michiganensis subsp. nebraskensis and has potential as a field test. The targeted sequence also has potential application in other molecular detection platforms.
RF driven sulfur lamp having driving electrodes arranged to cool the lamp
Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.
1998-10-20
A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.
Monazah, A; Zeinoddini, M; Saeeidinia, A R
2017-08-01
Coxsackievirus B3 (CVB3) is a member of the genus Enterovirus within the family Picornaviridae and is an important pathogen of viral myocarditis, which accounts for more than 50% viral myocarditis cases. VP1 is major capsid protein that this region has a low homology in both amino acid and nucleotide sequences among Enteroviruses. Therefore we have chosen this region for designed a set of RT-LAMP primers for CVB3 detection. For this the total RNA was extracted from 24-h post infected-HeLa cells with complete cytopathic effect (CPE), and applied to a one-step reverse transcription loop-mediated isothermal amplification reaction (RT-LAMP) using CVB3-specific primers. The optimization of RT-LAMP reaction was carried out with three variables factors including MgSO 4 concentration, temperature and time of incubation. Amplification was analyzed by using 2% agarose gel electrophoresis and ethidium bromide and SYBR Green staining. Our results were shown the ladder-like pattern of the VP1 gene amplification. The LAMP reaction mix was optimized and the best result observed at 4mM MgSO 4 and 60°C for 90min incubation. RT-LAMP had high sensitivity and specificity for detection of CVB3 infection. This method can be used as a rapid and easy diagnostic test for detection of CVB3 in clinical laboratories. Copyright © 2017 Elsevier B.V. All rights reserved.
Pham, Thu Hang; Peter, Jonathan; Mello, Fernanda C Q; Parraga, Tommy; Lan, Nguyen Thi Ngoc; Nabeta, Pamela; Valli, Eloise; Caceres, Tatiana; Dheda, Keertan; Dorman, Susan E; Hillemann, Doris; Gray, Christen M; Perkins, Mark D
2018-03-01
To evaluate the diagnostic performance of TB-LAMP, a manual molecular tuberculosis (TB) detection method, and provide comparison to the Xpert MTB/RIF assay. In a large multicentre study, two sputum samples were collected from participants with TB symptoms in reference laboratories in Peru, South Africa, Brazil, and Vietnam. Each sample was tested with TB-LAMP. The reference standard consisted of four direct smears, four cultures, and clinical and radiological findings. Individuals negative on conventional tests were followed up after 8 weeks. The Xpert MTB/RIF assay was performed on fresh or frozen samples as a molecular test comparison. A total of 1036 adults with suspected TB were enrolled. Among 375 culture-confirmed TB cases with 750 sputum samples, TB-LAMP detected 75.6% (95% confidence interval (CI) 71.8-79.4%), including 97.9% (95% CI 96.4-99.4%) of smear-positive TB samples and 46.6% (95% CI 40.6-52.7%) of smear-negative TB samples. Specificity in 477 culture-negative participants not treated for TB (954 sputum samples) was 98.7% (95% CI 97.9-99.6%). TB-LAMP test results were indeterminate in 0.3% of cases. TB-LAMP detects nearly all smear-positive and half of smear-negative TB cases and has a high specificity when performed in reference laboratories. Performance was similar to the Xpert MTB/RIF assay. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
David, Alexandre; Tiveron, Marie-Catherine; Defays, Axel; Beclin, Christophe; Camosseto, Voahirana; Gatti, Evelina; Cremer, Harold; Pierre, Philippe
2007-01-15
The brain-associated LAMP-like molecule (BAD-LAMP) is a new member of the family of lysosome associated membrane proteins (LAMPs). In contrast to other LAMPs, which show a widespread expression, BAD-LAMP expression in mice is confined to the postnatal brain and therein to neuronal subpopulations in layers II/III and V of the neocortex. Onset of expression strictly parallels cortical synaptogenesis. In cortical neurons, the protein is found in defined clustered vesicles, which accumulate along neurites where it localizes with phosphorylated epitopes of neurofilament H. In primary neurons, BAD-LAMP is endocytosed, but is not found in classical lysosomal/endosomal compartments. Modification of BAD-LAMP by addition of GFP revealed a cryptic lysosomal retention motif, suggesting that the cytoplasmic tail of BAD-LAMP is actively interacting with, or modified by, molecules that promote its sorting away from lysosomes. Analysis of BAD-LAMP endocytosis in transfected HeLa cells provided evidence that the protein recycles to the plasma membrane through a dynamin/AP2-dependent mechanism. Thus, BAD-LAMP is an unconventional LAMP-like molecule and defines a new endocytic compartment in specific subtypes of cortical projection neurons. The striking correlation between the appearance of BAD-LAMP and cortical synatogenesis points towards a physiological role of this vesicular determinant for neuronal function.
Discharge lamp with reflective jacket
MacLennan, Donald A.; Turner, Brian P.; Kipling, Kent
2001-01-01
A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.
30 CFR 20.10 - Tests (class 1 and 2 lamps).
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Tests (class 1 and 2 lamps). 20.10 Section 20..., AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.10 Tests (class 1 and 2 lamps). Such tests will be made as are necessary to prove the adequacy of a lamp or any of...
30 CFR 20.10 - Tests (class 1 and 2 lamps).
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests (class 1 and 2 lamps). 20.10 Section 20..., AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.10 Tests (class 1 and 2 lamps). Such tests will be made as are necessary to prove the adequacy of a lamp or any of...
30 CFR 20.10 - Tests (class 1 and 2 lamps).
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests (class 1 and 2 lamps). 20.10 Section 20..., AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.10 Tests (class 1 and 2 lamps). Such tests will be made as are necessary to prove the adequacy of a lamp or any of...
Long-term life testing of Geostationary Operational Environmental Satellite (GOES) encoder lamps
NASA Technical Reports Server (NTRS)
Powers, Charles E.
1992-01-01
The aging characteristics and lifetimes of tungsten filament encoder lamps were determined as a function of operating voltage and filament material. For pure tungsten and thoria doped (1 pct.) filament lamps, crystal grain growth over the center portion of the filament leads to the ultimate failure of the lamp. The development of notches associated with this grain growth is the cause of lamp burn out. Eventually, one of the notches will 'etch' through the filament, causing it to fail open. For rhenium doped (3 pct.) filament lamps, distortion of the filament leads to the ultimate failure of the lamp. The lifetime of these lamps is about 1 year at an operating voltage of 5.0 volts. The pure tungsten filament lamps have the longest average lifetime, and the thoria doped filament lamps have the shortest at 5.0 volts. The lifetimes of these lamps is about 7 years at an operating voltage of 3.5 volts. Data suggest that the rhenium doped lamps will have the longest average lifetime at 3.5 volts, and the thoria doped will have the shortest. These lifetimes are comparable to the desired lifetimes of 7 years.
LED lamp color control system and method
Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.
2013-02-05
An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.
Tanabe, N; Go, K; Sakurada, Y; Imasawa, M; Mabuchi, F; Chiba, T; Abe, K; Kashiwagi, K
2011-01-01
To develop a remote-operating slit lamp microscope system (the remote slit lamp) as the core for highly specialized ophthalmology diagnoses, and to compare the utility of this system with the conventional slit lamp microscope system (the conventional slit lamp) in making a diagnosis. The remote slit lamp system was developed. Three factors were evaluated in comparison to the conventional slit lamp. The ability to acquire skills was investigated using a task loading system among specialists and residents in ophthalmology. Participants repeated a task up to ten times and the time required for each task was analyzed. The consistency of the two systems in making a diagnosis was investigated using eyes of patients with ocular diseases as well as healthy volunteers. The remote slit lamp is composed of a patient's unit and ophthalmologist's unit connected by high-speed internet. The two units share images acquired by the slit lamp in addition to the images and voices of patients and ophthalmologists. Both ophthalmology specialists and residents could minimize the completion times after several trials. The remote slit lamp took more time than the conventional slit lamp. Both systems showed a high consistency in evaluations among eyes with healthy eyes or those with ocular diseases. The remote slit lamp has a similar diagnostic ability, but required more examination time in comparison to the conventional slit lamp. The currently developed remote slit lamp has the potential to be employed for tele-medicine purposes in the field of ophthalmology.
Danon disease – dysregulation of autophagy in a multisystem disorder with cardiomyopathy
Rowland, Teisha J.; Sweet, Mary E.; Mestroni, Luisa; Taylor, Matthew R. G.
2016-01-01
ABSTRACT Danon disease is a rare, severe X-linked form of cardiomyopathy caused by deficiency of lysosome-associated membrane protein 2 (LAMP-2). Other clinical manifestations include skeletal myopathy, cognitive defects and visual problems. Although individuals with Danon disease have been clinically described since the early 1980s, the underlying molecular mechanisms involved in pathological progression remain poorly understood. LAMP-2 is known to be involved in autophagy, and a characteristic accumulation of autophagic vacuoles in the affected tissues further supports the idea that autophagy is disrupted in this disease. The LAMP2 gene is alternatively spliced to form three splice isoforms, which are thought to play different autophagy-related cellular roles. This Commentary explores findings from genetic, histological, functional and tissue expression studies that suggest that the specific loss of the LAMP-2B isoform, which is likely to be involved in macroautophagy, plays a crucial role in causing the Danon phenotype. We also compare findings from mouse and cellular models, which have allowed for further molecular characterization but have also shown phenotypic differences that warrant attention. Overall, there is a need to better functionally characterize the LAMP-2B isoform in order to rationally explore more effective therapeutic options for individuals with Danon disease. PMID:27165304
Improved Performance of Loop-Mediated Isothermal Amplification Assays via Swarm Priming.
Martineau, Rhett L; Murray, Sarah A; Ci, Shufang; Gao, Weimin; Chao, Shih-Hui; Meldrum, Deirdre R
2017-01-03
This work describes an enhancement to the loop-mediated isothermal amplification (LAMP) reaction which results in improved performance. Enhancement is achieved by adding a new set of primers to conventional LAMP reactions. These primers are termed "swarm primers" based on their relatively high concentration and their ability to create new amplicons despite the theoretical lack of single-stranded annealing sites. The primers target a region upstream of the FIP/BIP primer recognition sequences on opposite strands, substantially overlapping F1/B1 sites. Thus, despite the addition of a new primer set to an already complex assay, no significant increase in assay complexity is incurred. Swarm priming is presented for three DNA templates: Lambda phage, Synechocystis sp. PCC 6803 rbcL gene, and human HFE. The results of adding swarm primers to conventional LAMP reactions include increased amplification speed, increased indicator contrast, and increased reaction products. For at least one template, minor improvements in assay repeatability are also shown. In addition, swarm priming is shown to be effective at increasing the reaction speed for RNA amplification via RT-LAMP. Collectively, these results suggest that the addition of swarm primers will likely benefit most if not all existing LAMP assays based on state-of-the-art, six-primer reactions.
The effect of cap lamp lighting on postural control and stability
Sammarco, John J.; Pollard, Jonisha P.; Porter, William L.; Dempsey, Patrick G.; Moore, Caitlin T.
2015-01-01
Researchers at the National Institute for Occupational Safety and Health (NIOSH) are conducting mine illumination research with the objective of improving miner safety. Slips, trips, and falls (STFs) are the second leading accident class (18.1%, n = 2,374) of nonfatal lost-time injuries at underground mines (MSHA, 2005–2009). Factors contributing to STFs include recognition of hazards as well as postural balance and age. Improved lighting may enable better hazard recognition and reduce the impact of postural balance and age. Previous research has shown that cap lamp technology that used light-emitting diodes (LEDs) has improved hazard detection. This study was an initial investigation to determine if cap lamp lighting significantly influences measures of static postural stability (displacement and velocity of center of pressure). Results of this investigation showed no significant differences in the balance measures of interest between cap lamps tested. However, balance was shown to significantly decline (p < 0.05) when tested in an underground coal mine compared to the laboratory testing condition. Relevance to industry: Underground coal mine workers wear cap lamps on their hard hats as their primary light source to illuminate nearby areas where their vision is directed. Proper illumination may improve miner safety by improving their STF hazard recognition and balance. PMID:26472917
2012-01-01
Background Loop-mediated isothermal amplification (LAMP) is a novel strategy which amplifies DNA with high sensitivity and rapidity under isothermal conditions. In the present study, the performance of the repetitive insertion mobile element (RIME)-LAMP and human serum resistance-associated gene (SRA)-LAMP assays were evaluated using clinical specimens obtained from four male patients from Luangwa and Zambezi valleys in Zambia and Zimbabwe, respectively. Findings The cases reported in this preliminary communication were all first diagnosed by microscopy, through passive surveillance, and confirmed by both RIME-LAMP and SRA-LAMP. A good correlation between microscopy and LAMP was observed and contributed to staging and successful treatment of patient. RIME-LAMP and SRA-LAMP complimented each other well in all the cases. Conclusions Both RIME-LAMP and SRA-LAMP were able to detect Trypanosoma brucei rhodesiense DNA in patient blood and CSF and hence confirmed HAT in the parasitaemic patients. Our study indicates that the LAMP technique is a potential tool for HAT diagnosis, staging and may be useful for making therapeutic decisions. However, no statistically significant conclusion may be drawn due to the limited sample size used in the present study. It is thus imperative to conduct a detailed study to further evaluate the potential of LAMP as a bedside diagnostic test for HAT. PMID:23211002
40 CFR 458.40 - Applicability; description of the carbon black lamp process subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... carbon black lamp process subcategory. 458.40 Section 458.40 Protection of Environment ENVIRONMENTAL... CATEGORY Carbon Black Lamp Process Subcategory § 458.40 Applicability; description of the carbon black lamp... production of carbon black by the lamp process. ...
Environmental impacts of lighting technologies - Life cycle assessment and sensitivity analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Welz, Tobias; Hischier, Roland, E-mail: Roland.Hischier@empa.ch; Hilty, Lorenz M.
2011-04-15
With two regulations, 244/2009 and 245/2009, the European Commission recently put into practice the EuP Directive in the area of lighting devices, aiming to improve energy efficiency in the domestic lighting sector. This article presents a comprehensive life cycle assessment comparison of four different lighting technologies: the tungsten lamp, the halogen lamp, the conventional fluorescent lamp and the compact fluorescent lamp. Taking advantage of the most up-to-date life cycle inventory database available (ecoinvent data version 2.01), all life cycle phases were assessed and the sensitivity of the results for varying assumptions analysed: different qualities of compact fluorescent lamps (production phase),more » different electricity mixes (use phase), and end-of-life scenarios for WEEE recycling versus municipal solid waste incineration (disposal phase). A functional unit of 'one hour of lighting' was defined and the environmental burdens for the whole life cycle for all four lamp types were calculated, showing a clearly lower impact for the two gas-discharge lamps, i.e. the fluorescent and the compact fluorescent lamp. Differences in the product quality of the compact fluorescent lamps reveal to have only a very small effect on the overall environmental performance of this lamp type; a decline of the actual life time of this lamp type doesn't result in a change of the rank order of the results of the here examined four lamp types. It was also shown that the environmental break-even point of the gas-discharge lamps is reached long before the end of their expected life-span. All in all, it can be concluded that a change from today's tungsten lamp technology to a low-energy-consuming technology such as the compact fluorescent lamp results in a substantial environmental benefit.« less
Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghosal, Bikash; Banik, Alak; Vats, Vaibhav
2011-10-20
Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rbmore » lamp under various operating conditions are reported in the paper.« less
Meagher, Robert J.; Ball, Cameron Scott; Langevin, Stanley A.; ...
2016-01-25
In this study, collection of mosquitoes and testing for vector-borne viruses is a key surveillance activity that directly influences the vector control efforts of public health agencies, including determining when and where to apply insecticides. Vector control districts in California routinely monitor for three human pathogenic viruses including West Nile virus (WNV), Western equine encephalitis virus (WEEV), and St. Louis encephalitis virus (SLEV). Reverse transcription quantitative polymerase chain reaction (RT-qPCR) offers highly sensitive and specific detection of these three viruses in a single multiplex reaction, but this technique requires costly, specialized equipment that is generally only available in centralized publicmore » health laboratories. We report the use of reverse transcription loop-mediated isothermal amplification (RT-LAMP) to detect WNV, WEEV, and SLEV RNA extracted from pooled mosquito samples collected in California, including novel primer sets for specific detection of WEEV and SLEV, targeting the nonstructural protein 4 (nsP4) gene of WEEV and the 3’ untranslated region (3’-UTR) of SLEV. Our WEEV and SLEV RT-LAMP primers allowed detection of <0.1 PFU/reaction of their respective targets in <30 minutes, and exhibited high specificity without cross reactivity when tested against a panel of alphaviruses and flaviviruses. Furthermore, the SLEV primers do not cross-react with WNV, despite both viruses being closely related members of the Japanese encephalitis virus complex. The SLEV and WEEV primers can also be combined in a single RT-LAMP reaction, with discrimination between amplicons by melt curve analysis. Although RT-qPCR is approximately one order of magnitude more sensitive than RT-LAMP for all three targets, the RT-LAMP technique is less instrumentally intensive than RT-qPCR and provides a more cost-effective method of vector-borne virus surveillance.« less
49 CFR 234.221 - Lamp voltage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Lamp voltage. 234.221 Section 234.221..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be maintained at not less than 85 percent of the prescribed rating for the lamp. ...
49 CFR 234.221 - Lamp voltage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Lamp voltage. 234.221 Section 234.221..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be maintained at not less than 85 percent of the prescribed rating for the lamp. ...
Physics of Incandescent Lamp Burnout
ERIC Educational Resources Information Center
Gluck, Paul; King, John
2008-01-01
Incandescent lamps with tungsten filaments have been in use for about a century while being gradually replaced by fluorescent lamps; in another generation both will quite probably be largely replaced by light-emitting diodes. Incandescent lamps (simply called "lamps" in what follows) burn out after a lifetime that depends mostly on the temperature…
40 CFR 273.5 - Applicability-lamps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...
30 CFR 75.522-1 - Incandescent and fluorescent lamps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...
40 CFR 273.5 - Applicability-lamps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...
49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Lamps operable, prohibition of obstructions of lamps and reflectors. 393.9 Section 393.9 Transportation Other Regulations Relating to Transportation... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and...
47 CFR 17.54 - Rated lamp voltage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...
49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Lamps operable, prohibition of obstructions of lamps and reflectors. 393.9 Section 393.9 Transportation Other Regulations Relating to Transportation... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and...
49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Lamps operable, prohibition of obstructions of lamps and reflectors. 393.9 Section 393.9 Transportation Other Regulations Relating to Transportation... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and...
30 CFR 75.522-1 - Incandescent and fluorescent lamps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...
47 CFR 17.54 - Rated lamp voltage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...
30 CFR 75.522-1 - Incandescent and fluorescent lamps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...
30 CFR 75.522-1 - Incandescent and fluorescent lamps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...
40 CFR 273.5 - Applicability-lamps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...
47 CFR 17.54 - Rated lamp voltage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...
47 CFR 17.54 - Rated lamp voltage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...
30 CFR 75.522-1 - Incandescent and fluorescent lamps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...
40 CFR 273.5 - Applicability-lamps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...
47 CFR 17.54 - Rated lamp voltage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...
49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Lamps operable, prohibition of obstructions of lamps and reflectors. 393.9 Section 393.9 Transportation Other Regulations Relating to Transportation... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and...
40 CFR 273.5 - Applicability-lamps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...
Feng, Jiawang; Tang, Shiming; Liu, Lideng; Kuang, Xiaoshan; Wang, Xiaoyu; Hu, Songnan; You, Shuzhu
2015-03-01
Here, we developed a loop-mediated isothermal amplification (LAMP) assay for 11 common transgenic target DNA in GMOs. Six sets of LAMP primer candidates for each target were designed and their specificity, sensitivity, and reproductivity were evaluated. With the optimized LAMP primers, this LAMP assay was simply run within 45-60 min to detect all these targets in GMOs tested. The sensitivity, specificity, and reproductivity of the LAMP assay were further analyzed in comparison with those of Real-Time PCR. In consistent with real-time PCR, detection of 0.5% GMOs in equivalent background DNA was possible using this LAMP assay for all targets. In comparison with real-time PCR, the LAMP assay showed the same results with simple instruments. Hence, the LAMP assay developed can provide a rapid and simple approach for routine screening as well as specific events detection of many GMOs.
Life cycle analysis of greenhouse gas emissions for fluorescent lamps in mainland China.
Chen, Sha; Zhang, Jiaxing; Kim, Junbeum
2017-01-01
China is the world's largest emitter of carbon dioxide, and it is also one of the largest fluorescent lamp consuming and producing country in the world. However, there are few studies evaluating greenhouse gas (GHG) emissions of fluorescent lamps in China. This analysis compared GHG emissions of compact fluorescent lamps with linear fluorescent lamps using life cycle assessment method in China's national conditions. The GHG emissions of fluorescent lamps from their manufacture to the final disposal phase on the national level of China were also quantified. The results indicate that the use phase dominates the GHG emissions for both lamps. Linear fluorescent lamp is a better source of light compared to compact fluorescent lamp with respect to GHG emissions. The analysis found that in 2011, China generated around 710.90milliontons CO 2 -eq associated with fluorescent lamps. The raw material production and use phases accounted for major GHG emissions. More than half of GHG emissions during the domestic production were embodied in the exported lamps in recent years. This urges the government to take necessary measures that lead to more environmental friendly production, consumption and trade patterns. Copyright © 2016 Elsevier B.V. All rights reserved.
Kusumawati, Asmarani; Tampubolon, Issabellina Dwades; Hendarta, Narendra Yoga; Salasia, Siti Isrina Oktavia; Wanahari, Tenri Ashari; Mappakaya, Basofi Ashari; Hartati, Sri
2015-09-01
Jembrana disease virus (JDV) is a viral pathogen that causes Jembrana disease in Bali cattle (Bos javanicus) with high mortality rate. An easy and rapid diagnostic method is essential for further control this disease. We used a reverse transcription loop-mediated isothermal amplification (RT-LAMP) combined with lateral flow dipstick (LFD), based on conserved tm subunit of Jembrana disease virus env gene. The RT-LAMP conditions were optimized by varying the concentration of MgSO4, betaine, dNTP, and temperature as well as the time and duration of reaction. The primers sensitivity for JDV was confirmed. The method was able to detect env-tm gene dilution which contained 2 × 10(-15) g of template. Comparatively, the sensitivity of RT-LAMP/LFD was 100-fold more sensitive than reverse transcription-polymerase chain reaction. The primers specificity for JDV was also confirmed using positive and negative controls. This work also showed that virus detection could be done not only on total RNA extracted from blood but various organs could also be analyzed for the presence of JDV using RT-LAMP/LFD method. The whole process, including the LAMP reaction and the LFD hybridization step only lasts approximately 75 min. Results of analysis can be easily observed with naked eyes without addition of any chemical or further analysis. The combination of RT-LAMP with LFD makes the method a more suitable diagnostic tool in conditions where sophisticated and expensive equipments are not available for field investigations on Jembrana disease in Bali cattle.
NASA Astrophysics Data System (ADS)
Ishii, Mie; Moriyama, Takayoshi; Toda, Masahiro; Kohmoto, Kohtaro; Saito, Masako
White light-emitting diodes (LED) are well suited for museum lighting because they emit neither UV nor IR radiation, which damage artifacts. The color degradation of natural dyes and blue scale standards (JIS L 0841) by white LED lamps are examined, and the performance of white LED lamps for museum lighting is evaluated. Blue scale standard grades 1-6 and silk fabrics dyed with 22 types of natural dyes classified as mid to highly responsive in a CIE technical report (CIE157:2004) were exposed to five types of white LED lamps using different luminescence methods and color temperatures. Color changes were measured at each 15000 lx·hr (500 lx at fabric surface × 300 hr) interval ten times. The accumulated exposure totaled 150000 lx·hr. The data on conventional white LED lamps and previously reported white fluorescent (W) and museum fluorescent (NU) lamps was evaluated. All the white LED lamps showed lower fading rates compared with a W lamp on a blue scale grade 1. The fading rate of natural dyes in total was the same between an NU lamp (3000 K) and a white LED lamp (2869 K). However, yellow natural dyes showed higher fading rates with the white LED lamp. This tendency is due to the high power characteristic of the LED lamp around 400-500 nm, which possibly contributes to the photo-fading action on the dyes. The most faded yellow dyes were Ukon (Curcuma longa L.) and Kihada (Phellodendron amurense Rupr.), and these are frequently used in historic artifacts such as kimono, wood-block prints, and scrolls. From a conservation point of view, we need to continue research on white LED lamps for use in museum lighting.
Waterfield, Thomas; Patenall, Bethany; McKenna, James; Fairley, Derek
2017-12-01
Despite successful vaccination programmes meningococcal disease (MD) remains the leading infectious cause of septicaemia and death in children in the UK and Ireland. 1,2 The early diagnosis of MD significantly improves outcomes with reduced morbidity and mortality. 1,2 The early stages of MD are often indistinguishable from a simple viral illness making an early positive diagnosis of MD difficult. 1 Hibergene have developed a commercially available bedside Loop-mediated isothermal AMPlification PCR (LAMP-MD) test that is a highly sensitive 0.89 (95%CI 0.72-0.96) and specific 1.0 (95%CI 0.97-1.0) for identifying children with invasive MD (4) (figure 1).emermed;34/12/A895-a/F1F1F1Figure 1 AIMS: The aims of this RCEM funded study were:Assess the ease of use and suitability for the EDDetermine the time taken to perform the testIndependently verify LAMP-MD performance against TaqMan quantitative PCR. The LAMP-MD was assessed for practicality and ease of use within the ED including an assessment of training needs, footprint and health and safety requirements.For verification of the Hibergene LAMP-MD analyser and assay we used dry nasopharyngeal swabs sent for viral screening. Additional verification was undertaken using N. meningitidis genomic DNA spiked over a range of concentrations. This included serotypes A, B, C, W, X and Y and a dilution series to determine the limit of detection. All samples were then analysed using real time TaqMan qPCR. The LAMP-MD analyser was easy to use and could be accommodated in the EDThe mean time for detection of Meningococcal DNA was 14.01 minDetection of meningococcal serogroups A, B, C, W, X and Z was confirmedThe detection limit for dry nasopharyngeal swabs was below 2 genomic copies per µlNo non-specific amplification was observed in 17 randomly selected negative clinical swabsThe LAMP-MD assay was 100% sensitive and specific relative to real-time TaqMAN PCR. LAMP-MD is a practical, rapid point of care test that can reliably detect all Meningococcal serotypes in less than 15 min.Funding has been secured to perform a PERUKI supported study to investigate the potential for LAMP-MD in the diagnosis of meningococcal disease in children. Meningitis Research Foundation. Meningococcal Meningitis and Septicaemia Guidance Notes 2014.Ó Maoldomhnaigh, et al. Invasive meningococcal disease in children in Ireland . PMID: 27566800.NICE. Management of petechial rash .Bourke TW, et al. Diagnostic accuracy of loop-mediated isothermal amplification as a near-patient test for meningococcal disease in children . PMID: 25728843. © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Schurer, Kees
1994-03-01
We ran some tests on the effect of dimming of metal halide (MH) lamps upon the stability and the spectral quality of the light output. Lamps used were a new Philips lamp HPI-T 250W, a similar Philips lamp with a few thousand burning hours and a new Osram lamp HQI-T 250W/D. The ballast was a BBC type DJ 250/2KS, the starter a BAS TORGI type MZN 250 SE and the dimmer an Elstrom Control System type ERHQ-T 250. Power was derived from a Philips stabilizer, type PE 1602. Lamp output was monitored with a PAR meter. Spectra were taken at 100% and at 50% output as measured with the PAR meter. Lamps were allowed to stabilize at any setting for 30 minutes before measurements were made. Lamp manufacturers advise against dimming for fear of poor stability and intolerable changes of the spectrum. However, none of the lamps showed a decrease in stability, no flicker or wandering of the discharge, and the changes of the spectrum were not negligible, but certainly not dramatic. Lamps of either manufacture retain their white color, relative peak heights of spectral lines did shift, but no gaps in the spectrum occurred. Spectra taken at 50% with 30 minutes intervals coincided. Differences between the new and the older Philips lamp were noticeable, but not really significant.
NASA Technical Reports Server (NTRS)
Schurer, Kees
1994-01-01
We ran some tests on the effect of dimming of metal halide (MH) lamps upon the stability and the spectral quality of the light output. Lamps used were a new Philips lamp HPI-T 250W, a similar Philips lamp with a few thousand burning hours and a new Osram lamp HQI-T 250W/D. The ballast was a BBC type DJ 250/2KS, the starter a BAS TORGI type MZN 250 SE and the dimmer an Elstrom Control System type ERHQ-T 250. Power was derived from a Philips stabilizer, type PE 1602. Lamp output was monitored with a PAR meter. Spectra were taken at 100% and at 50% output as measured with the PAR meter. Lamps were allowed to stabilize at any setting for 30 minutes before measurements were made. Lamp manufacturers advise against dimming for fear of poor stability and intolerable changes of the spectrum. However, none of the lamps showed a decrease in stability, no flicker or wandering of the discharge, and the changes of the spectrum were not negligible, but certainly not dramatic. Lamps of either manufacture retain their white color, relative peak heights of spectral lines did shift, but no gaps in the spectrum occurred. Spectra taken at 50% with 30 minutes intervals coincided. Differences between the new and the older Philips lamp were noticeable, but not really significant.
Recent Advances in Lighting Science
NASA Astrophysics Data System (ADS)
Lapatovich, Walter P.
2004-10-01
Lighting is a global industry supplying a wide array of devices and systems that emit light ranging from incandescent lamps to light emitting diodes to electric discharge lamps. Electric discharge lamps are the most familiar plasma devices to most people. This work focuses on plasma light sources, some advances in this area and recent trends. Plasma light sources fall into two broad categories, namely low pressure and high pressure. The low-pressure lamps operate in the range of 40 to 500 Pa while the high-pressure lamps operate in the range of 0.1 to 15 MPa. The corresponding electron temperatures are about 1eV and 0.5 eV for the low and high-pressure lamps respectively. High-pressure lamps are treated under the assumption of local thermodynamic equilibrium wherein the gas temperature is equilibrated with the electron temperature. They are often called high intensity discharge lamps because of their intrinsically high radiance. Within these two broad categories are many subgroups, perhaps the most important being mercury and non-mercury containing lamps. An example of a low pressure, mercury-containing lamp is the ubiquitous fluorescent lamp. Attempts to improve the efficiency of these lamps center around inductive excitation techniques and two-photon phosphor development. The plasma research on mercury-free low-pressure lamps is focused on finding substitutes for a mercury-rare gas discharge. Several ultraviolet emitting candidates have been explored which emit both UV and visible. Longer wavelength UV is of interest because of the parallel development of phosphors mated with LED excitation wavelengths around 380nm. Several examples will be discussed. There have been major advances in high intensity discharge lamps with and without mercury. Mercury containing metal halide lamps are now being fabricated from translucent ceramic envelopes instead of the conventional vitreous silica. The higher temperature tolerant envelope materials permit using discharges in vapors hitherto unacceptable because of chemical reactions. Temperature driven chemical reactions (which affect lamp life, starting and stability) are better understood. Lamps are better designed with finite element thermal modeling and thermodynamic computational tools. Improved understanding of molecular processes in the energy transport within the plasma has opened possibilities for new types of light sources relying heavily on molecular emission. Examples of lamps containing sulfur, indium, thallium and rare earth halides will be discussed. General trends in plasma based light source have been towards lower wattage, directed visible output, high quality visible output, longer life and mercury-free lamps. Consumer demand for high tech, high performance lighting devices has broadened the use of HID lamps in automobiles, video/data display and medical/technical applications. Short arc gap lamps (1mm) with a luminance exceeding that of the sun's surface (1600cd/mm2 -as observed from earth), and operating with extreme line broadening lead the video projection market. Low wattage HID lamps coupled with tailored optics can direct the light output more precisely leading to reduced light pollution and better system throughput. Tailoring of the driving electrical waveforms have enabled stable operation, controlled the effects of species segregation and improved lamp life and performance.
30 CFR 20.10 - Tests (class 1 and 2 lamps).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests (class 1 and 2 lamps). 20.10 Section 20... 1 and 2 lamps). Such tests will be made as are necessary to prove the adequacy of a lamp or any of... (storage-battery lamps of class 1). (e) Temperature tests. ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Class 2 lamps. 20.9 Section 20.9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.9 Class 2 lamps. (a) Safety. (1...
46 CFR 167.40-25 - Signaling lamp.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...
30 CFR 75.1703-1 - Permissible lamps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...
49 CFR 392.33 - Obscured lamps or reflective devices/material.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Obscured lamps or reflective devices/material. 392... REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...
49 CFR 392.33 - Obscured lamps or reflective devices/material.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Obscured lamps or reflective devices/material. 392... REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...
46 CFR 167.40-25 - Signaling lamp.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...
30 CFR 75.1703-1 - Permissible lamps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...
46 CFR 167.40-25 - Signaling lamp.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...
30 CFR 75.1703-1 - Permissible lamps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...
30 CFR 75.1703-1 - Permissible lamps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...
30 CFR 75.1703-1 - Permissible lamps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...
49 CFR 393.23 - Power supply for lamps.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Power supply for lamps. 393.23 Section 393.23... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the...
49 CFR 392.33 - Obscured lamps or reflective devices/material.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Obscured lamps or reflective devices/material. 392... REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...
49 CFR 393.23 - Power supply for lamps.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Power supply for lamps. 393.23 Section 393.23... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the...
46 CFR 167.40-25 - Signaling lamp.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...
46 CFR 167.40-25 - Signaling lamp.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...
49 CFR 392.33 - Obscured lamps or reflective devices/material.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Obscured lamps or reflective devices/material. 392... REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...
10 CFR 429.40 - Candelabra base incandescent lamps and intermediate base incandescent lamps.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Candelabra base incandescent lamps and intermediate base....40 Candelabra base incandescent lamps and intermediate base incandescent lamps. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to candelabra base...
10 CFR 429.40 - Candelabra base incandescent lamps and intermediate base incandescent lamps.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Candelabra base incandescent lamps and intermediate base....40 Candelabra base incandescent lamps and intermediate base incandescent lamps. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to candelabra base...
49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER... Electrical Wiring § 393.9 Lamps operable, prohibition of obstructions of lamps and reflectors. (a) All lamps... any part of the load, or its covering by dirt, or other added vehicle or work equipment, or otherwise...
CALiPER Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2014-12-31
This CALiPER report examines the characteristics of a subset of lamps from CALiPER Retail Lamps Study 3 in more detail. Specifically, it focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers.
Naidoo, N; Ghai, M; Moodley, K; Mkize, L; Martin, L; McFarlane, S; Rutherford, S
2017-12-01
Ratoon stunt (RS) caused by bacterium Leifsonia xyli subsp. xyli (Lxx) results in substantial yield losses in sugarcane (Saccharum sp. L. hybrid). Since RS does not produce reliable symptoms in the field, laboratory-based techniques are necessary for detection. Loop-mediated isothermal amplification (LAMP) assay overcomes the limitations of laboratory-based techniques which are costly, time consuming and cannot be used for near-field detection. A sensitive LAMP assay was developed to detect Lxx at 65°C in 30 min. However, carry-over contamination affected the reliability of the assay. In the present study, contaminants were successfully eliminated by incorporation of uracil nucleoside glycosylase (1 U μl -1 ) into the LAMP assay and incubation for 10 min at 37°C. To avoid the use of colorimetric reagents, lateral flow devices were successfully used for the detection of LAMP products and were equally sensitive to detection by agarose gel electrophoresis. The use of exudate from leaf sheath discs as an alternate template for the LAMP assay was found to be less sensitive than xylem sap. The preprepared master mix could be stored for up to 4 months at -20°C without any reduction in performance. These changes make the assay suitable for near-field detection in laboratories with basic facilities. This study presents a modified loop-mediated isothermal amplification (LAMP) assay for the detection of Leifsonia xyli subsp. xyli. Modifications include incorporation of uracil nucleoside glycosylase to eliminate carry-over contamination and substitution of colorimetric detection for the use of lateral flow devices. LAMP master mix was preprepared and was stably stored up to 4 months at -20°C. Sugarcane leaf sheaths worked well as a substitute to xylem sap as template, although the sensitivity was lower. These modifications allow the assay to be conducted without contamination concerns and reduction in set up time, making it ideal for near-field diagnosis. © 2017 The Society for Applied Microbiology.
LRO-LAMP Observations of the Lunar Exosphere Coordinated with LADEE
NASA Astrophysics Data System (ADS)
Grava, C.; Retherford, K. D.; Greathouse, T. K.; Gladstone, R.; Hurley, D.; Cook, J. C.; Stern, S. A.; Feldman, P. D.; Kaufmann, D. E.; Miles, P. F.; Pryor, W. R.; Halekas, J. S.
2014-12-01
The polar orbiting Lunar Reconnaissance Orbiter's (LRO) Lyman Alpha Mapping Project (LAMP) carried out an atmospheric campaign during the month of December 2013, at the same time the Lunar Atmospheric and Dust Environment Explorer (LADEE) mission was sampling the lunar exosphere in a retrograde equatorial orbit. Observations of the lunar exosphere were performed by LAMP during a solar "beta-90" geometry, i.e. riding along the lunar terminator. During this geometry, the LAMP nadir-pointed line of sight to the nightside surface also includes illuminated columns of foreground emissions from exospheric species, which is invaluable in the study of the tenuous lunar exosphere. Other types of maneuvers to probe the lunar exosphere were also performed by LAMP/LRO during this campaign. During backward pitch slews, the LRO spacecraft was pitched to look opposite its direction of motion to a point just inside the limb in the nightside region around the polar terminator. Forward pitch slews were also obtained, and the angles of 63 deg or 77 deg from nadir were set depending on the polar region observed. Finally, during lateral roll slews, LRO rotated by ~60 deg towards the nightside limb, maximizing the amount of illuminated atmosphere in the foreground probed by the LAMP field of view. We extract day to day density variations on helium and/or upper limits for numerous other species that were accessible to both LAMP and LADEE (e.g., Ar, Ne, O, and H2). Moreover, constraints on helium density will complement measurements of solar wind alpha particles (He++) from the ARTEMIS (Acceleration, Reconnection, Turbulence, & Electrodynamics of Moon's Interaction with the Sun) mission. This comparison will provide a comprehensive picture of composition, abundance, and spatial and temporal variations of volatiles of the lunar exosphere, combining equatorial (LADEE) and polar (LAMP) measurements for the first time. Volatiles in the lunar exosphere, especially water, are of paramount importance in the context of lunar exploration, since the compelling hypothesis of their storage in Permanently Shaded Regions (PSRs) was advanced in the second half of the last century.
Design and construction of a home-made and cheaper argon arc lamp
NASA Astrophysics Data System (ADS)
Sabaeian, Mohammad; Nazari-Tarkarani, Zeinab; Ebrahimzadeh, Azadeh
2018-05-01
The authors report on the design and construction of an argon arc lamp which provides noticeably a cheaper instrument for laser and medical applications. Cesium-doped tungsten and pure tungsten rods were used, respectively, for the lamp cathode and anode. To seal the glassy tube, a 50-50 Fe-Ni alloy was successfully used as a medium to attach the tungsten electrodes to the borosilicate glass tube. Starting voltage of the lamp versus the gas pressure, operation voltage-current diagram at various gas pressures, and lamp spectrum in the various pressures were measured. A comparison was made with krypton arc lamp. The lamp operation was satisfactory without any crack or fracture during lightening operation. The results showed that the lamp-lightening threshold voltage depends linearly on the pressure and arc length in such a way that there is an increase in the voltage by raising these two parameters. We have also observed that by increasing the argon pressure, there is a shifting in emission spectrum from the ultraviolet to the visible region. Comparison with krypton arc lamp indicated that argon lamp needs a higher threshold lightening voltage.
Optogalvanic effect and laser-induced current oscillations in hollow-cathode lamps
NASA Astrophysics Data System (ADS)
Eldakli, Mohsan S. A.; Ivković, Saša S.; Obradović, Bratislav M.
2017-03-01
This paper presents a study of two commercial hollow-cathode lamps (HCLs) with the intention of demonstrating different phenomena in gas discharges. The optogalvanic effect in both HCLs is produced by a laser diode radiated at the wavelength that corresponds to neon transition 1s2-2p2 at 659.89 nm. The voltage-current characteristics of the lamps are explained using a classical theory of hollow-cathode discharge, while the optogalvanic signal is treated as a small perturbation of the discharge current. For certain values of voltage self-sustained current oscillations are observed in one of the HCLs. In the same HCL laser-induced optogalvanic dumped oscillations are detected. A phenomenological model that includes the effective circuit parameters of the discharge is used to explain the oscillation characteristics.
Lamp reliability studies for improved satellite rubidium frequency standard
NASA Technical Reports Server (NTRS)
Frueholz, R. P.; Wun-Fogle, M.; Eckert, H. U.; Volk, C. H.; Jones, P. F.
1982-01-01
In response to the premature failure of Rb lamps used in Rb atomic clocks onboard NAVSTAR GPS satellites experimental and theoretical investigations into their failure mechanism were initiated. The primary goal of these studies is the development of an accelerated life test for future GPS lamps. The primary failure mechanism was identified as consumption of the lamp's Rb charge via direct interaction between Rb and the lamp's glass surface. The most effective parameters to accelerate the interaction between the Rb and the glass are felt to be RF excitation power and lamp temperature. Differential scanning calorimetry is used to monitor the consumption of Rb within a lamp as a function of operation time. This technique yielded base line Rb consumption data for GPS lamps operating under normal conditions.
Test plane uniformity analysis for the MSFC solar simulator lamp array
NASA Technical Reports Server (NTRS)
Griner, D. B.
1976-01-01
A preliminary analysis was made on the solar simulator lamp array. It is an array of 405 tungsten halogen lamps with Fresnel lenses to achieve the required spectral distribution and collimation. A computer program was developed to analyze lamp array performance at the test plane. Measurements were made on individual lamp lens combinations to obtain data for the computer analysis. The analysis indicated that the performance of the lamp array was about as expected, except for a need to position the test plane within 2.7 m of the lamp array to achieve the desired 7 percent uniformity of illumination tolerance.
Hoehl, Melanie M; Weißert, Michael; Dannenberg, Arne; Nesch, Thomas; Paust, Nils; von Stetten, Felix; Zengerle, Roland; Slocum, Alexander H; Steigert, Juergen
2014-06-01
This paper introduces a disposable battery-driven heating system for loop-mediated isothermal DNA amplification (LAMP) inside a centrifugally-driven DNA purification platform (LabTube). We demonstrate LabTube-based fully automated DNA purification of as low as 100 cell-equivalents of verotoxin-producing Escherichia coli (VTEC) in water, milk and apple juice in a laboratory centrifuge, followed by integrated and automated LAMP amplification with a reduction of hands-on time from 45 to 1 min. The heating system consists of two parallel SMD thick film resistors and a NTC as heating and temperature sensing elements. They are driven by a 3 V battery and controlled by a microcontroller. The LAMP reagents are stored in the elution chamber and the amplification starts immediately after the eluate is purged into the chamber. The LabTube, including a microcontroller-based heating system, demonstrates contamination-free and automated sample-to-answer nucleic acid testing within a laboratory centrifuge. The heating system can be easily parallelized within one LabTube and it is deployable for a variety of heating and electrical applications.
LAMP: a micro-satellite based soft x-ray polarimeter for astrophysics
NASA Astrophysics Data System (ADS)
She, Rui; Feng, Hua; Muleri, Fabio; Soffitta, Paolo; Xu, Renxin; Li, Hong; Bellazzini, Ronaldo; Wang, Zhanshan; Spiga, Daniele; Minuti, Massimo; Brez, Alessandro; Spandre, Gloria; Pinchera, Michele; Sgrò, Carmelo; Baldini, Luca; Wen, Mingwu; Shen, Zhengxiang; Pareschi, Giovanni; Tagliaferri, Gianpiero; Tayabaly, Kashmira; Salmaso, Bianca; Zhan, Yafeng
2015-08-01
The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite mission concept dedicated for astronomical X-ray polarimetry and is currently under early phase study. It consists of segmented paraboloidal multilayer mirrors with a collecting area of about 1300 cm2 to reflect and focus 250 eV X-rays, which will be detected by position sensitive detectors at the focal plane. The primary targets of LAMP include the thermal emission from the surface of pulsars and synchrotron emission produced by relativistic jets in blazars. With the expected sensitivity, it will allow us to detect polarization or place a tight upper limit for about 10 pulsars and 20 blazars. In addition to measuring magnetic structures in these objects, LAMP will also enable us to discover bare quark stars if they exist, whose thermal emission is expected to be zero polarized, while the thermal emission from neutron stars is believed to be highly polarized due to plasma polarization and the quantum electrodynamics (QED) effect. Here we present an overview of the mission concept, its science objectives and simulated observational results.
Controlling the vapor pressure of a mercury lamp
Grossman, Mark W.; George, William A.
1988-01-01
The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.
Li, Lixuan; Li, Jia
2015-05-01
To study the effects of lentivirus-mediated short hairpin RNA (shRNA) silencing of lysosome-associated membrane protein type 2A (LAMP2A) expression on the proliferation of multiple myeloma cells. The constructed shRNA lentiviral vector was applied to infect human multiple myeloma cell line MM.1S, and stable expression cell line was obtained by puromycin screening. Western blotting was used to verify the inhibitory effect on LAMP2A protein expression. MTT assay was conducted to detect the effect of knocked-down LAMP2A on MM.1S cell proliferation, and the anti-tumor potency of suberoylanilide hydroxamic acid (SAHA) against the obtained MM.1S LAMP2A(shRNA) stable cell line. Lactate assay was performed to observe the impact of low LAMP2A expression on cell glycolysis. The stable cell line with low LAMP2A expression were obtained with the constructed human LAMP2A-shRNA lentiviral vector. Down-regulation of LAMP2A expression significantly inhibited MM.1S cell proliferation and enhanced the anti-tumor activity of SAHA. Interestingly, decreased LAMP2A expression also inhibited MM.1S cell lactic acid secretion. Down-regulation of LAMP2A expression could inhibit cell proliferation in multiple myeloma cells.
Evaluation of the Potential Optical Radiation Hazards with Led Lamps Intended for Home Use.
James, Robert H; Landry, Robert J; Walker, Bennett N; Ilev, Ilko K
2017-01-01
The authors evaluated the potential for ocular damage from optical radiation emitted by Light Emitting Diode (LED) based lamps used for general illumination. Ten LED lamps were randomly selected off the shelf from a local home improvement store. The LEDs were behind diffusers in half of these lamps, while in the other half, the LEDs were clearly visible. In addition, a battery powered LED lantern having a LED source behind a diffuser was measured. The optical radiation emissions from two common incandescent lamps were also measured to compare the relative hazards of LED and incandescent lamps. All lamp samples were evaluated in accordance with procedures specified in the American National Standards Institute/Illuminating Engineering Society of North America (ANSI/IESNA) Standard RP-27.3. For comparison purposes, the lantern and 100 W incandescent lamps were also evaluated according to ANSI RP-27.1. These measurements indicate that no lamp evaluated poses any photobiological hazard, and therefore, all lamps fall in the RP-27.3 category of Exempt Group. However, when evaluated in accordance with RP-27.1, the 100 W incandescent lamp would be classified in Risk Group 1 (low risk), while the LED lantern would be classified in Risk Group 2 (moderate risk).
2008-10-01
which acts as a transformer with mutual inductance M. The value of M is a function of the current sheet position c. A i witch Bl ft...at an angle where the " film plane" of the camera is parallel to the plane FINAL REPORT FOR FA9550-06-1-0149: FARAD 45 Figure 3.3: Idealized...surface from time-integrated photographs obtained with a camera whose film plane is not parallel to the cone’s axis of symmetry. Due to these
30 CFR 20.11 - Material required for MSHA records.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.11... lamp as approved, are retained. These drawings are used to identify the lamp and its parts in the...) If MSHA so desires, parts of the lamps which are used in the tests will be retained as a permanent...
30 CFR 20.11 - Material required for MSHA records.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.11... lamp as approved, are retained. These drawings are used to identify the lamp and its parts in the...) If MSHA so desires, parts of the lamps which are used in the tests will be retained as a permanent...
30 CFR 20.11 - Material required for MSHA records.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.11... lamp as approved, are retained. These drawings are used to identify the lamp and its parts in the...) If MSHA so desires, parts of the lamps which are used in the tests will be retained as a permanent...
30 CFR 20.11 - Material required for MSHA records.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.11... lamp as approved, are retained. These drawings are used to identify the lamp and its parts in the...) If MSHA so desires, parts of the lamps which are used in the tests will be retained as a permanent...
49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the driver's will and be steady-burning. The headlamps shall be marked in accordance with FMVSS No... this paragraph. (b) Auxiliary driving lamps and front fog lamps. Commercial motor vehicles may be... aim of the lighting device from being disturbed while the vehicle is operating on public roads. (d...
Osman, Hana A M; Eltom, Kamal H; Musa, Nasreen O; Bilal, Nasreldin M; Elbashir, Mustafa I; Aradaib, Imadeldin E
2013-06-01
Crimean-Congo hemorrhagic fever (CCHF) virus (CCHFV) activity has been detected in Kordufan region of the Sudan in 2008 with high case-fatality rates in villages and rural hospitals in the region. Therefore, in the present study, a reverse transcription (RT) loop-mediated isothermal amplification (RT-LAMP) assay was developed and compared to nested RT-PCR for rapid detection of CCHFV targeting the small (S) RNA segment. A set of RT-LAMP primers, designed from a highly conserved region of the S segment of the viral genome, was employed to identify all the Sudanese CCHFV strains. The sensitivity studies indicated that the RT-LAMP detected 10fg of CCHFV RNA as determined by naked eye turbidity read out, which is more likely the way it would be read in a resource-poor setting. This level of sensitivity is good enough to detect most acute cases. Using agarose gel electrophoresis, the RT-LAMP assay detected as little as 0.1fg of viral RNA (equivalent to 50 viral particle). There was 100% agreement between results of the RT-LAMP and the nested PCR when testing 10-fold serial dilution of CCHFV RNA. The specificity studies indicated that there was no cross-reactivity with other related hemorrhagic fever viruses circulating in Sudan including, Rift Valley fever virus (RVFV), Dengue fever virus, and yellow fever virus. The RT-LAMP was performed under isothermal conditions at 63°C and no special apparatus was needed, which rendered the assay more economical and practical than real-time PCR in such developing countries, like Sudan. In addition, the RT-LAMP provides a valuable tool for rapid detection and differentiation of CCHFV during an outbreak of the disease in remote areas and in rural hospitals with resource-poor settings. Copyright © 2013 Elsevier B.V. All rights reserved.
Dinzouna-Boutamba, Sylvatrie-Danne; Yang, Hye-Won; Joo, So-Young; Jeong, Sookwan; Na, Byoung-Kuk; Inoue, Noboru; Lee, Won-Ki; Kong, Hyun-Hee; Chung, Dong-Il; Goo, Youn-Kyoung; Hong, Yeonchul
2014-06-30
Malaria that is caused by Plasmodium vivax is the most widely distributed human malaria. Its recent resurgence in many parts of the world, including the Republic of Korea (ROK), emphasizes the importance of improved access to the early and accurate detection of P. vivax to reduce disease burden. In this study, a rapid and efficient loop-mediated isothermal amplification (LAMP)-based method was developed and validated using blood samples from malaria-suspected patients. A LAMP assay targeting the α-tubulin gene for the detection of P. vivax was developed with six primers that recognize different regions of the target gene. The diagnostic performance of the α-tubulin LAMP assay was compared to three other tests: microscopic examinations, rapid diagnostic tests (RDTs), and nested polymerase chain reactions (PCRs) using 177 whole blood specimens obtained from ROK military personnel from May to December 2011. The α-tubulin LAMP assay was highly sensitive with a detection limit of 100 copies of P. vivax α-tubulin gene per reaction within 50 min. It specifically amplified the target gene only from P. vivax. Validation of the α-tubulin LAMP assay showed that the assay had the highest sensitivity (P < 0.001 versus microscopy; P = 0.0023 versus RDT) when nested PCR was used as the gold standard and better agreement (concordance: 94.9%, kappa value: 0.865) with nested PCR than RDT and microscopy. A Receiver Operation Characteristics analysis showed that the diagnostic accuracy of the α-tubulin LAMP assay for vivax malaria was higher (Area Under Curve = 0.908) than RDT and microscopy. This study showed that the P. vivax α-tubulin LAMP assay, which can be used to diagnose early infections of vivax malaria, is an alternative molecular diagnostic tool and a point-of-care test that may help to prevent transmission in endemic areas.
Techathuvanan, Chayapa; Draughon, Frances Ann; D'Souza, Doris Helen
2011-02-01
Novel rapid Salmonella detection assays without the need for sophisticated equipment or labor remain in high demand. Real-time reverse transcriptase PCR (RT-PCR) assays, though rapid and sensitive, require expensive thermocyclers, while a novel RT loop-mediated isothermal amplification (RT-LAMP) method requires only a simple water bath. Our objective was to compare the detection sensitivity of Salmonella Typhimurium from the pork processing environment by RT-LAMP, RT-PCR, and culture-based assays. Carcass and surface swabs and carcass rinses were obtained from a local processing plant. Autoclaved carcass rinses (500 ml) were spiked with Salmonella Typhimurium and filtered. Filters were placed in stomacher bags containing tetrathionate broth (TTB) and analyzed with or without 10-h enrichment at 37 °C. Natural swabs were stomached with buffered peptone water, and natural carcass rinses were filtered, preenriched, and further enriched in TTB. Serially-diluted enriched samples were enumerated by spread plating on xylose lysine Tergitol 4 agar. RNA was extracted from 5 ml of enriched TTB with TRIzol. RT-LAMP assay using previously described invA primers was conducted at 62 °C for 90 min in a water bath with visual detection and by gel electrophoresis. SYBR Green I-based-real-time RT-PCR was carried out with invA primers followed by melt temperature analysis. The results of RT-LAMP detection for spiked carcass rinses were comparable to those of RT-PCR and cultural plating, with detection limits of 1 log CFU/ml, although they were obtained significantly faster, within 24 h including preenrichment and enrichment. RT-LAMP showed 4 of 12 rinse samples positive, while RT-PCR showed 1 of 12 rinse samples positive. For swabs, 6 of 27 samples positive by RT-LAMP and 5 of 27 by RT-PCR were obtained. This 1-day RT-LAMP assay shows promise for routine Salmonella screening by the pork industry. Copyright ©, International Association for Food Protection
NASA Astrophysics Data System (ADS)
Bérces, Attila; ten Kate, I. L.; Fekete, A.; Hegedus, M.; Garry, J. R. C.; Lammer, Helmut; Ehrenfreund, Pascale; Peeters, Zan; Kovacs, G.; Ronto, G.
Mars is considered as a main target for astrobiologically relevant exploration programmes. In order to explain the non-detection of organic material to a detection level of several parts per billion (ppb) by the Viking landers, several hypotheses have been suggested, including degradation processes occurring on the martian surface and in the martian soil and subsurface. UV exposure experiments have been performed in which thin layers of glycine ( 300 nm), and aqueous suspensions of phage T7 and isolated T7 DNA were irradiated with a Deuterium lamp and for comparison with a Xenon arc lamp, modified to simulate the solar irradiation on the surface of Mars (MarsUV). The glycine sample was subjected to 24 hours of irradiation with MarsUV. The results of this glycine experiment show a destruction rate comparable to the results of previous experiments in which thin layers of glycine were irradiated with a deuterium lamp (ten Kate et al., 2005, 2006). After exposure of different doses of simulated Martian UV radiation a decrease of the biological activity of phages and characteristic changes in the UV absorption spectrum have been detected, indicating the UV damage of isolated and intraphage T7 DNA. The results of our experiments show that intraphage DNA is 4 times more sensitive to simulated martian UV and deuterium lamp radiation than isolated T7 DNA. This result indicates the significant role that phage proteins play in the UV damage. The effect of simulated martian radiation is smaller than the biological defects observed after the exposure with a deuterium lamp for both cases, in intraphage and isolated DNA, despite of the 100 times larger intensity of the MarsUV lamp. The detected spectral differences are about ten times smaller; the biological activity is about 3 - 4 times smaller, indicating that the shorter wavelength UV radiation from the deuterium lamp is more effective in inducing DNA damage, irrespective of being intraphage or isolated.
49 CFR 393.23 - Power supply for lamps.
Code of Federal Regulations, 2014 CFR
2014-10-01
... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the...
Loop-Mediated Isothermal Amplification (LAMP) Signature Identification Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torres, C.
2009-03-17
This is an extendable open-source Loop-mediated isothermal AMPlification (LAMP) signature design program called LAVA (LAMP Assay Versatile Analysis). LAVA was created in response to limitations of existing LAMP signature programs.
Method and apparatus for implementing material thermal property measurement by flash thermal imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Jiangang
A method and apparatus are provided for implementing measurement of material thermal properties including measurement of thermal effusivity of a coating and/or film or a bulk material of uniform property. The test apparatus includes an infrared camera, a data acquisition and processing computer coupled to the infrared camera for acquiring and processing thermal image data, a flash lamp providing an input of heat onto the surface of a two-layer sample with an enhanced optical filter covering the flash lamp attenuating an entire infrared wavelength range with a series of thermal images is taken of the surface of the two-layer sample.
Is ultraviolet radiation on haemodialysis RO water beneficial?
Stragier, A
2005-01-01
The quality of dialysis fluids has become increasingly important in the treatment of HD patients. Purified water represents over 95% of its volume. Bacterial and endotoxin content of Reverse Osmosis (RO) water is usually kept under control by bacterial filters, inserted in the distribution departure loop, and by monthly disinfection of the distribution circuit; the simpler the circuit, the better. This paper reports 12 years experience during which Ultraviolet Irradiation (UV) has replaced bacterial filters. To keep the bacterial growth under control in a complex RO water circuit (including a tank and multiple loops) a simple UV lamp was inserted in the departure line. It proved sufficient to keep bacterial count within AAMI norms. Failure of the UV lamp was associated with a rise of up to 500 cfu/ml in the last (fourth week) before routine disinfection. Normal levels were again obtained after replacement of the UV lamp. Six years later, a second UV lamp was added on the return loop. Bacterial counts and endotoxin levels in RO water promptly fell to <1 cfu/ml and <0.125 EU, till today. It is concluded that UV lamps should be favoured over bacterial filters in systems that are not disinfected daily, such as the RO water circuit. The principle of UV irradiation is explained and its advantage over bacterial filters is discussed. Future possible applications of UV are presented.
Numerical and experimental analyses of the radiant heat flux produced by quartz heating systems
NASA Technical Reports Server (NTRS)
Turner, Travis L.; Ash, Robert L.
1994-01-01
A method is developed for predicting the radiant heat flux distribution produced by tungsten filament, tubular fused-quartz envelope heating systems with reflectors. The method is an application of Monte Carlo simulation, which takes the form of a random walk or ray tracing scheme. The method is applied to four systems of increasing complexity, including a single lamp without a reflector, a single lamp with a Hat reflector, a single lamp with a parabolic reflector, and up to six lamps in a six-lamp contoured-reflector heating unit. The application of the Monte Carlo method to the simulation of the thermal radiation generated by these systems is discussed. The procedures for numerical implementation are also presented. Experiments were conducted to study these quartz heating systems and to acquire measurements of the corresponding empirical heat flux distributions for correlation with analysis. The experiments were conducted such that several complicating factors could be isolated and studied sequentially. Comparisons of the experimental results with analysis are presented and discussed. Good agreement between the experimental and simulated results was obtained in all cases. This study shows that this method can be used to analyze very complicated quartz heating systems and can account for factors such as spectral properties, specular reflection from curved surfaces, source enhancement due to reflectors and/or adjacent sources, and interaction with a participating medium in a straightforward manner.
Direct detection of Marek's disease virus in poultry dust by loop-mediated isothermal amplification.
Woźniakowski, Grzegorz; Samorek-Salamonowicz, Elżbieta
2014-11-01
Marek's disease virus (MDV) is a serious concern for poultry production and represents a unique herpesvirus model. MDV can be shed by doubly infected chickens despite vaccination. The fully infectious MDV particles are produced in the feather follicle epithelium (FFE), and MDV remains infectious for many months in fine skin particles and feather debris. Molecular biology methods including PCR and real-time PCR have been shown to be valuable for the detection of MDV DNA in farm dust. Recently, loop-mediated isothermal amplification (LAMP) was found to be useful in the detection of MDV in feathers and internal organs of infected chickens. LAMP is also less affected by the inhibitors present in DNA samples. Taking into account the advantages of LAMP, direct detection of MDV DNA in poultry dust has been conducted in this research. The detection of MDV DNA was possible in 11 out of the 12 examined dust samples without DNA extraction. The DNA was retrieved from dust samples by dilution and incubation at 95 °C for 5 min. The direct detection of MDV DNA in the dust was possible within 30 min using a water bath and UV light. The results were confirmed by electrophoresis and melting curve analysis of the LAMP products. Our results show that LAMP may be used to test for the presence of virulent MDV in poultry farm dust without DNA extraction.
2010-01-01
Background The rickettsial bacterium Ehrlichia ruminantium is the causative agent of heartwater, a potential zoonotic disease of ruminants transmitted by ticks of the genus Amblyomma. The disease is distributed in nearly all of sub-Saharan Africa and some islands of the Caribbean, from where it threatens the American mainland. This report describes the development of two different loop-mediated isothermal amplification (LAMP) assays for sensitive and specific detection of E. ruminantium. Results Two sets of LAMP primers were designed from the pCS20 and sodB genes. The detection limits for each assay were 10 copies for pCS20 and 5 copies for sodB, which is at least 10 times higher than that of the conventional pCS20 PCR assay. DNA amplification was completed within 60 min. The assays detected 16 different isolates of E. ruminantium from geographically distinct countries as well as two attenuated vaccine isolates. No cross-reaction was observed with genetically related Rickettsiales, including zoonotic Ehrlichia species from the USA. LAMP detected more positive samples than conventional PCR but less than real-time PCR, when tested with field samples collected in sub-Saharan countries. Conclusions Due to its simplicity and specificity, LAMP has the potential for use in resource-poor settings and also for active screening of E. ruminantium in both heartwater-endemic areas and regions that are at risk of contracting the disease. PMID:21087521
The prevalence of interdigital erythrasma: a prospective study from an outpatient clinic in Turkey.
Polat, Muhterem; İlhan, Mustafa N
2015-03-01
Erythrasma is a superficial skin infection caused by Corynebacterium minutissimum . Interdigital erythrasma is the most common form and is easily confused with tinea pedis. The aim of this study was to determine the prevalence of interdigital erythrasma in patients with clinically suspected tinea pedis. This study was performed between January 1, 2011, and January 31, 2012. It included 182 patients who presented with concerns about interdigital lesions. All of the patients were examined with a Wood's lamp, and smears were stained with Gram's method. Direct examination with 20% potassium hydroxide was performed. Of 182 patients with interdigital lesions, 73 (40.1%) were diagnosed as having erythrasma. The mean ± SD age of the patients with erythrasma was 45.52 ± 10.83 years (range, 22-70 years). Most of the patients with erythrasma were women (56.2%). The most often clinical finding was desquamation. Using only Wood's lamp examination or Gram's staining resulted in 31 (42.5%) or 14 (19.2%) positive patients, respectively. Using Wood's lamp examination and Gram's staining concurrently resulted in 28 positive patients (38.4%). Interdigital erythrasma is a common condition and can be difficult to differentiate from tinea pedis. Simple and rapid diagnosis can be made with Wood's lamp examination, but Gram's staining is also a useful method, especially in patients with negative Wood's lamp examination findings.
Gong, Jiansen; Zhuang, Linlin; Zhu, Chunhong; Shi, Shourong; Zhang, Di; Zhang, Linji; Yu, Yan; Dou, Xinhong; Xu, Bu; Wang, Chengming
2016-04-01
Salmonella spp. pose a threat to both human and animal health, with more than 2600 serovars having been reported to date. Salmonella serovars are usually identified by slide agglutination tests, which are labor intensive and time consuming. In an attempt to develop a more rapid screening method for the major poultry Salmonella serovars, we developed a loop-mediated isothermal amplification (LAMP) assay, which directly detected the sefA gene, a fimbrial operon gene existing in several specific serovars of Salmonella enterica including the major poultry serovars, namely Salmonella enterica serovar Enteritidis (Salmonella Enteritidis) and Salmonella enterica serovar Gallinarum (Salmonella Gallinarum). With the 177 bacterial strains we tested, positive reactions were only observed with 85 strains of serovar Salmonella Enteritidis and Salmonella Gallinarum. The detection limit of the LAMP assay was 4 CFU/reaction with genomic DNAs of Salmonella Enteritidis (ATCC 13076) from pure culture and 400 CFU/ reaction with DNA extracted from spiked chicken feces. The LAMP assay was more sensitive than conventional culture, especially without enrichment, in detecting Salmonella Enteritidis (CMCC 50041) in the spiked fecal samples. The results show the sefA LAMP method is a rapid, sensitive, specific, and practical method for directly detection of Salmonella Enteritidis and Salmonella Gallinarum in chickens. The sefA LAMP assay can potentially serve as new on-site diagnostics in the poultry industry.
Besuschio, Susana A; Llano Murcia, Mónica; Benatar, Alejandro F; Monnerat, Severine; Cruz, Israel; Picado, Albert; Curto, María de Los Ángeles; Kubota, Yutaka; Wehrendt, Diana P; Pavia, Paula; Mori, Yasuyoshi; Puerta, Concepción; Ndung'u, Joseph M; Schijman, Alejandro G
2017-07-01
This study aimed to assess analytical parameters of a prototype LAMP kit that was designed for detection of Trypanosoma cruzi DNA in human blood. The prototype is based on the amplification of the highly repetitive satellite sequence of T.cruzi in microtubes containing dried reagents on the inside of the caps. The reaction is carried out at 65°C during 40 minutes. Calcein allows direct detection of amplified products with the naked eye. Inclusivity and selectivity were tested in purified DNA from Trypanosoma cruzi stocks belonging to the six discrete typing units (DTUs), in DNA from other protozoan parasites and in human DNA. Analytical sensitivity was estimated in serial dilutions of DNA samples from Sylvio X10 (Tc I) and CL Brener (Tc VI) stocks, as well as from EDTA-treated or heparinized blood samples spiked with known amounts of cultured epimastigotes (CL Brener). LAMP sensitivity was compared after DNA extraction using commercial fiberglass columns or after "Boil & Spin" rapid preparation. Moreover, the same DNA and EDTA-blood spiked samples were subjected to standardized qPCR based on the satellite DNA sequence for comparative purposes. A panel of peripheral blood specimens belonging to Chagas disease patients, including acute, congenital, chronic and reactivated cases (N = 23), as well as seronegative controls (N = 10) were evaluated by LAMP in comparison to qPCR. LAMP was able to amplify DNAs from T. cruzi stocks representative of the six DTUs, whereas it did not amplify DNAs from Leishmania sp, T. brucei sp, T. rangeli KPN+ and KPN-, P. falciparum and non-infected human DNA. Analytical sensitivity was 1x10-2 fg/μL of both CL Brener and Sylvio X10 DNAs, whereas qPCR detected up to 1x 10-1 fg/μL of CL Brener DNA and 1 fg/μl of Sylvio X10 DNA. LAMP detected 1x10-2 parasite equivalents/mL in spiked EDTA blood and 1x10-1 par.eq/mL in spiked heparinized blood using fiberglass columns for DNA extraction, whereas qPCR detected 1x10-2 par.eq./mL in EDTA blood. Boil & Spin extraction allowed detection of 1x10-2 par.eq /mL in spiked EDTA blood and 1 par.eq/ml in heparinized blood. LAMP was able to detect T.cruzi infection in peripheral blood samples collected from well-characterised seropositive patients, including acute, congenital, chronic and reactivated Chagas disease. To our knowledge, this is the first report of a prototype LAMP kit with appropriate analytical sensitivity for diagnosis of Chagas disease patients, and potentially useful for monitoring treatment response.
Besuschio, Susana A.; Llano Murcia, Mónica; Benatar, Alejandro F.; Monnerat, Severine; Cruz, Israel; Picado, Albert; Curto, María de los Ángeles; Kubota, Yutaka; Wehrendt, Diana P.; Pavia, Paula; Mori, Yasuyoshi; Puerta, Concepción; Ndung'u, Joseph M.
2017-01-01
This study aimed to assess analytical parameters of a prototype LAMP kit that was designed for detection of Trypanosoma cruzi DNA in human blood. The prototype is based on the amplification of the highly repetitive satellite sequence of T.cruzi in microtubes containing dried reagents on the inside of the caps. The reaction is carried out at 65°C during 40 minutes. Calcein allows direct detection of amplified products with the naked eye. Inclusivity and selectivity were tested in purified DNA from Trypanosoma cruzi stocks belonging to the six discrete typing units (DTUs), in DNA from other protozoan parasites and in human DNA. Analytical sensitivity was estimated in serial dilutions of DNA samples from Sylvio X10 (Tc I) and CL Brener (Tc VI) stocks, as well as from EDTA-treated or heparinized blood samples spiked with known amounts of cultured epimastigotes (CL Brener). LAMP sensitivity was compared after DNA extraction using commercial fiberglass columns or after “Boil & Spin” rapid preparation. Moreover, the same DNA and EDTA-blood spiked samples were subjected to standardized qPCR based on the satellite DNA sequence for comparative purposes. A panel of peripheral blood specimens belonging to Chagas disease patients, including acute, congenital, chronic and reactivated cases (N = 23), as well as seronegative controls (N = 10) were evaluated by LAMP in comparison to qPCR. LAMP was able to amplify DNAs from T. cruzi stocks representative of the six DTUs, whereas it did not amplify DNAs from Leishmania sp, T. brucei sp, T. rangeli KPN+ and KPN-, P. falciparum and non-infected human DNA. Analytical sensitivity was 1x10-2 fg/μL of both CL Brener and Sylvio X10 DNAs, whereas qPCR detected up to 1x 10−1 fg/μL of CL Brener DNA and 1 fg/μl of Sylvio X10 DNA. LAMP detected 1x10-2 parasite equivalents/mL in spiked EDTA blood and 1x10-1 par.eq/mL in spiked heparinized blood using fiberglass columns for DNA extraction, whereas qPCR detected 1x10-2 par.eq./mL in EDTA blood. Boil & Spin extraction allowed detection of 1x10-2 par.eq /mL in spiked EDTA blood and 1 par.eq/ml in heparinized blood. LAMP was able to detect T.cruzi infection in peripheral blood samples collected from well-characterised seropositive patients, including acute, congenital, chronic and reactivated Chagas disease. To our knowledge, this is the first report of a prototype LAMP kit with appropriate analytical sensitivity for diagnosis of Chagas disease patients, and potentially useful for monitoring treatment response. PMID:28727723
NASA Technical Reports Server (NTRS)
Dever, Joyce A.; Pietromica, Anthony J.; Stueber, Thomas J.; Sechkar, Edward A.; Messer, Russell K.
2002-01-01
Vacuum ultraviolet (VUV) radiation of wavelengths between 115 and 200 nm produced by the Sun in the space environment can degrade polymer films, producing changes in their optical, mechanical, and chemical properties. These effects are particularly important for thin polymer films being considered for ultralightweight space structures, because, for most polymers, VUV radiation is absorbed in a thin surface layer. The NASA Glenn Research Center has developed facilities and methods for long-term ground testing of polymer films to evaluate space environmental VUV radiation effects. VUV exposure can also be used as part of combined or sequential simulated space environmental exposures to determine combined damaging effects with other aspects of the space environment, which include solar ultraviolet radiation, solar flare x-rays, electron and proton radiation, atomic oxygen (for low-Earth-orbit missions), and temperature effects. Because the wavelength sensitivity of VUV damage is not well known for most materials, Glenn's VUV facility uses a broad-spectrum deuterium lamp with a magnesium fluoride window that provides output between 115 and 200 nm. Deuterium lamps of this type were characterized by the National Institute of Standards and Technology and through measurements at Glenn. Spectral irradiance measurements show that from approximately 115 to 160 nm, deuterium lamp irradiance can be many times that of air mass zero solar irradiance, and as wavelength increases above approximately 160 nm, deuterium lamp irradiance decreases in comparison to the Sun. The facility is a cryopumped vacuum chamber that achieves a system pressure of approximately 5310(exp -6) torr. It contains four individual VUV-exposure compartments in vacuum, separated by water-cooled copper walls to minimize VUV radiation and any sample contamination cross interactions between compartments. Each VUV-exposure compartment contains a VUV deuterium lamp, a motor-controlled sample stage coupled with a moveable cesium iodide VUV phototube, and two thermocouples for temperature measurement. The vacuum chamber and exterior equipment is shown. Each VUV lamp is located at the top of the chamber with its projection-tube pushed through an O-ring compression fitting. The lamp assemblies are located on ports that can be isolated from the rest of the vacuum chamber, permitting maintenance or replacement of the lamps without breaking vacuum in the main chamber where the samples are located. A view of two of the four interior VUV-exposure compartments, including the moveable sample stages and detector holders is also shown. Glenn is using this facility to support testing of Next Generation Space Telescope sunshield materials that is being led by the NASA Goddard Space Flight Center and to develop an understanding of the wavelength, intensity, and temperature dependence of VUV-induced polymer degradation.
Evaluation of Heating Methods for Thermal Structural Testing of Large Structures
NASA Technical Reports Server (NTRS)
Daryabeigi, Kamran; Sikora, Joseph G.; Caldwell, Darrell L., Jr.
1998-01-01
An experimental study was conducted to evaluate different heating methods for thermal structural testing of large scale structures at temperatures up to 350 F as part of the High Speed Research program. The heating techniques evaluated included: radiative/convective, forced convective, and conductive. The radiative/convective heaters included finned strip heaters, and clear and frosted quartz lamps. The forced convective heating was accomplished by closed loop circulation of heated air. The conductive heater consisted of heating blankets. The tests were conducted on an 1/8 inch thick stainless steel plate in a custom-built oven. The criteria used for comparing the different heating methods included test specimen temperature uniformity, heater response time, and consumed power. The parameters investigated included air circulation in the oven, reflectance of oven walls, and the orientation of the test specimen and heaters (vertical and horizontal). It was found that reflectance of oven walls was not an important parameter. Air circulation was necessary to obtain uniform temperatures only for the vertically oriented specimen. Heating blankets provided unacceptably high temperature non-uniformities. Quartz lamps with internal air circulation had the lowest power consumption levels. Using frosted quartz lamps with closed loop circulation of cool air, and closed loop circulation of heated air provided the fastest response time.
Physics of Incandescent Lamp Burnout
NASA Astrophysics Data System (ADS)
Gluck, Paul; King, John
2008-01-01
Incandescent lamps with tungsten filaments have been in use for about a century while being gradually replaced by fluorescent lamps; in another generation both will quite probably be largely replaced by light-emitting diodes. Incandescent lamps (simply called lamps in what follows) burn out after a lifetime that depends mostly on the temperature of the filament and hence the applied voltage. A full-term project (about 100 hours) on lamp burnout was carried out by two students in 1965 and has been briefly described. Many aspects of the physics of lamps have been dealt with in articles that have appeared in this journal, in the American Journal of Physics, and in Physics Education.2,3
Design and investigation of a novel concentrator used in solar fiber lamp
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Kaiyan; School of Physical Science and Technology, Guangxi University, Nanning 530004; Zheng, Hongfei
2009-11-15
A novel concentrator used in solar fiber lamp has been designed and made. The method of the design has been introduced. The lamp has been tested under the real solar condition and the experiment curves have been given. The light transmission will be influenced by the structure of the lamp and the diameter of the fiber, which has been studied in this paper. The experimental results show that the brightness of this solar fiber lamp is about the brightness of a 6-W ordinary electrical energy-saving lamp. The computer simulation for the lamp has been presented and the improvement schemes aremore » proposed. (author)« less
Rapid detection of mecA and spa by the loop-mediated isothermal amplification (LAMP) method.
Koide, Y; Maeda, H; Yamabe, K; Naruishi, K; Yamamoto, T; Kokeguchi, S; Takashiba, S
2010-04-01
To develop a detection assay for staphylococcal mecA and spa by using loop-mediated isothermal amplification (LAMP) method. Staphylococcus aureus and other related species were subjected to the detection of mecA and spa by both PCR and LAMP methods. The LAMP successfully amplified the genes under isothermal conditions at 64 degrees C within 60 min, and demonstrated identical results with the conventional PCR methods. The detection limits of the LAMP for mecA and spa, by gel electrophoresis, were 10(2) and 10 cells per tube, respectively. The naked-eye inspections were possible with 10(3) and 10 cells for detection of mecA and spa, respectively. The LAMP method was then applied to sputum and dental plaque samples. The LAMP and PCR demonstrated identical results for the plaque samples, although frequency in detection of mecA and spa by the LAMP was relatively lower for the sputum samples when compared to the PCR methods. Application of the LAMP enabled a rapid detection assay for mecA and spa. The assay may be applicable to clinical plaque samples. The LAMP offers an alternative detection assay for mecA and spa with a great advantage of the rapidity.
Investigation of Passive Filter for LED Lamp
NASA Astrophysics Data System (ADS)
Sarwono, Edi; Facta, Mochammad; Handoko, Susatyo
2017-04-01
Light Emitting Diode lamp or LED lamp is one of the energy saving lamps nowadays widely used by consumers. However, LED lamp has contained harmonics caused by the rectifier circuit inside the lamp. Harmonics cause a quality problem in power system. As the harmonics present in current or voltage, the waveforms are distorted. Harmonics can lead to overheating in magnetic core of electrical equipments. In this paper, several tests are carried out to investigate the harmonic content of voltage and currents, and also the level of light intensity of the two brands of LED lamps. Measurements in this study are conducted by using HIOKI Power Quality Analyzer 3197. The test results show that the total harmonic distortion or THD of voltage on various brands of LED lamps did not exceed 5% as in compliance to the limit of IEEE standard 519-1992. The largest harmonic voltage is 2.9%, while maximum harmonic current for tested brands of LED lamp is 170.6%. The use of low pass filter in the form of LC filter was proposed. Based on experimental results, the application of LC filter at input side of LED lamp has successfully reduced THD current in the range of 85%-88%.
Lighting Systems For High Speed Photography Applying Special Metal Halide Discharge Lamps
NASA Astrophysics Data System (ADS)
Gillum, Keith M.; Steuernagel, K. H.
1983-03-01
High speed photography requires, in addition to a good color quality of the light source, a very high level of illumination. Conventional lighting systems utilizing incandescent lamps or other metal halide lamp types has inherent problems of inefficient light output or poor color quality. Heat generated by incandescent lamps and the power these sources require drive up operating and installation costs. A most economical and practical solution was devised by using the metal halide discharge lamp developed by OSRAM, GmbH of Munich, West Germany. This lamp trade marked the HMITM Metallogen was primarily developed for the needs of the television and motion picture film industry. Due to their high efficiency and other consistent operating qualities these lamps also fulfill the needs of high speed photography, e.g. in crash test facilities, when special engineering activities are carried out. The OSRAM HMITM lamp is an AC discharge metal halide lamp with rare earth additives to increase both the efficiency and light output qualities. Since the lamp is an AC source, a special method had to be developed to overcome the strobing effect, which is normal for AC lamps given their modulated light output, when used with high speed cameras, (e.g. with >1000 fps). This method is based on an increased frequency for the lamp supply voltage coupled with a mix of the light output achieved using a multiphase mains power supply. First developed in 1977, this system using the OSRAM HMITM lamps was installed in a crash test facility of a major automotive manufacturer in West Germany. The design resulted in the best lighting and performance ever experienced. Since that time several other motor companies have made use of this breakthrough. Industrial and scientific users are now considering additional applications use of this advanced high speed lighting system.
Adedeji, A. J.; Abdu, P. A.; Luka, P. D.; Owoade, A. A.; Joannis, T. M.
2017-01-01
Aim: This study was designed to optimize and apply the use of loop-mediated isothermal amplification (LAMP) as an alternative to conventional polymerase chain reaction (PCR) for the detection of herpesvirus of turkeys (HVT) (FC 126 strain) in vaccinated and non-vaccinated poultry in Nigeria. Materials and Methods: HVT positive control (vaccine) was used for optimization of LAMP using six primers that target the HVT070 gene sequence of the virus. These primers can differentiate HVT, a Marek’s disease virus (MDV) serotype 3 from MDV serotypes 1 and 2. Samples were collected from clinical cases of Marek’s disease (MD) in chickens, processed and subjected to LAMP and PCR. Results: LAMP assay for HVT was optimized. HVT was detected in 60% (3/5) and 100% (5/5) of the samples analyzed by PCR and LAMP, respectively. HVT was detected in the feathers, liver, skin, and spleen with average DNA purity of 3.05-4.52 μg DNA/mg (A260/A280) using LAMP. Conventional PCR detected HVT in two vaccinated and one unvaccinated chicken samples, while LAMP detected HVT in two vaccinated and three unvaccinated corresponding chicken samples. However, LAMP was a faster and simpler technique to carry out than PCR. Conclusion: LAMP assay for the detection of HVT was optimized. LAMP and PCR detected HVT in clinical samples collected. LAMP assay can be a very good alternative to PCR for detection of HVT and other viruses. This is the first report of the use of LAMP for the detection of viruses of veterinary importance in Nigeria. LAMP should be optimized as a diagnostic and research tool for investigation of poultry diseases such as MD in Nigeria. PMID:29263603
Controlling the vapor pressure of a mercury lamp
Grossman, M.W.; George, W.A.
1988-05-24
The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled. 2 figs.
Infrared Heat Lamps used in Drying Chemical Samples, September-October 1974
1974-10-01
reflected from the planchette exceeds current recommended limits. DD F2MM73 1473 ED’Tt0" OF ’MOV •*IS o"SOLETE UNCLASSIFIED SECÜmTY CLASSIFICATION OF... planchette exceeds current recommended limits. Recommendations include reducing reflected luminance from the sample planchette and placing a warning...Samples, Sep-Oct 74 Figure 1. Nuclear Associates Sample Dryer Showing Metal Planchettes and Heat Lamp at Top of Page •■;’^’""- ■■ ■ ■ *wmzm
Polarization spectroscopy of atomic erbium in a hollow cathode lamp
NASA Astrophysics Data System (ADS)
Ang'ong'a, Jackson; Gadway, Bryce
2018-02-01
In this work we perform polarization spectroscopy of erbium atoms in a hollow cathode lamp (HCL). We review the theory behind Doppler-free polarization spectroscopy, theoretically model the expected erbium polarization spectra, and compare the numerically calculated spectra to our experimental data. We further analyze the dependence of the measured spectra on the HCL current and the peak intensities of our pump and probe lasers to determine conditions. Applications include wavelength stabilization of diode laser radiation to the 400.91 nm erbium transition.
Wei, Ji Feng; Hu, Xiao Yang; Sun, Li Qun; Zhang, Kai; Chang, Yan
2015-03-20
The calibration method using a high-power halogen tungsten lamp as a calibration source has many advantages such as strong equivalence and high power, so it is very fit for the calibration of high-energy laser energy meters. However, high-power halogen tungsten lamps after power-off still reserve much residual energy and continually radiate energy, which is difficult to be measured. Two measuring systems were found to solve the problems. One system is composed of an integrating sphere and two optical spectrometers, which can accurately characterize the radiative spectra and power-time variation of the halogen tungsten lamp. This measuring system was then calibrated using a normal halogen tungsten lamp made of the same material as the high-power halogen tungsten lamp. In this way, the radiation efficiency of the halogen tungsten lamp after power-off can be quantitatively measured. In the other measuring system, a wide-spectrum power meter was installed far away from the halogen tungsten lamp; thus, the lamp can be regarded as a point light source. The radiation efficiency of residual energy from the halogen tungsten lamp was computed on the basis of geometrical relations. The results show that the halogen tungsten lamp's radiation efficiency was improved with power-on time but did not change under constant power-on time/energy. All the tested halogen tungsten lamps reached 89.3% of radiation efficiency at 50 s after power-on. After power-off, the residual energy in the halogen tungsten lamp gradually dropped to less than 10% of the initial radiation power, and the radiation efficiency changed with time. The final total radiation energy was decided by the halogen tungsten lamp's radiation efficiency, the radiation efficiency of residual energy, and the total power consumption. The measuring uncertainty of total radiation energy was 2.4% (here, the confidence factor is two).
Socha, W; Rola, J; Urban-Chmiel, R; Żmudziński, J F
2017-09-26
Bovine herpesvirus-1 (BoHV-1), a causative agent of Infectious Bovine Rhinotracheitis (IBR), is responsible for high economic losses in cattle farming industry. The use of testing methods that allow early detection of BoHV-1-infected animals is a key element of each program of IBR eradication. The aim of the study was to design and evaluate two variants of LAMP isothermal tests with SYBR Green fluorescence probes, specific to the genes encoding gD and gE glycoproteins of BoHV-1. LAMP gE BoHV-1 assay was able to distinguish between gE- and gE+ strains of the virus. Both LAMP gD and gE assays were specific to BoHV-1 and did not react with other related to BoHV-1 alphaherpesviruses. Sensitivity of LAMP gD was 2x104 copies of the viral genome whereas for LAMP gE it was 2x105. Diagnostic sensitivity calculated for LAMP gD was 64.7% whereas for LAMP gE it was 80%. Diagnostic specificity for LAMP gD and LAMP gE was 78.9% and 89.3%, respectively. LAMP assay can be a rapid and simple method of diagnosis of acute BoHV-1 infections and discrimination of gE- strains. However, relatively low diagnostic sensitivity of the method can limit its use in routine diagnostics.
Characterizing risk factors for pediatric lamp oil product exposures.
Sheikh, S; Chang, A; Kieszak, S; Law, R; Bennett, H K W; Ernst, E; Bond, G R; Spiller, H A; Schurz-Rogers, H; Chu, A; Bronstein, A C; Schier, J G
2013-11-01
Poisonings from lamp oil ingestion continue to occur worldwide among the pediatric population despite preventive measures such as restricted sale of colored and scented lamp oils. This suggests that optimal prevention practices for unintentional pediatric exposures to lamp oil have yet to be identified and/or properly implemented. To characterize demographic, health data, and potential risk factors associated with reported exposures to lamp oil by callers to poison centers (PCs) in the US and discuss their public health implications. This was a two part study in which the first part included characterizing all exposures to a lamp oil product reported to the National Poison Data System (NPDS) with regard to demographics, exposure, health, and outcome data from 1/1/2000 to 12/31/2010. Regional penetrance was calculated using NPDS data by grouping states into four regions and dividing the number of exposure calls by pediatric population per region (from the 2000 US census). Temporal analyses were performed on NPDS data by comparing number of exposures by season and around the July 4th holiday. Poisson regression was used to model the count of exposures for these analyses. In the second part of this project, in order to identify risk factors we conducted a telephone-based survey to the parents of children from five PCs in five different states. The 10 most recent lamp oil product exposure calls for each poison center were systematically selected for inclusion. Calls in which a parent or guardian witnessed a pediatric lamp oil product ingestion were eligible for inclusion. Data on demographics, exposure information, behavioral traits, and health were collected. A descriptive analysis was performed and Fisher's exact test was used to evaluate associations between variables. All analyses were conducted using SAS v9.3. Among NPDS data, 2 years was the most common patient age reported and states in the Midwestern region had the highest numbers of exposure calls compared to other regions. Exposure calls differed by season (p < 0.0001) and were higher around the July 4th holiday compared to the rest of the days in July (2.09 vs. 1.89 calls/day, p < 0.002). Most exposures occurred inside a house, were managed on-site and also had a "no effect" medical outcome. Of the 50 PC-administered surveys to parents or guardians, 39 (78%) met inclusion criteria for analysis. The majority of ingestions occurred in children that were 2 years of age, that were not alone, involved tiki torch fuel products located on a table or shelf, and occurred inside the home. The amount of lamp oil ingested did not appear to be associated with either the smell (p = 0.19) or the color of the oil (p = 1.00) in this small sample. Approximately half were asymptomatic (n = 18; 46%), and of those that reported symptoms, cough was the most common (n = 20, 95%) complaint. Lamp oil product exposures are most common among young children (around 2 years of age) while at home, not alone and likely as a result of the product being in a child-accessible location. Increasing parental awareness about potential health risks to children from these products and teaching safe storage and handling practices may help prevent both exposures and associated illness. These activities may be of greater benefit in Midwestern states and during summer months (including the period around the July 4th holiday).
Nakayama, Takako; Yamazaki, Takashi; Yo, Ayaka; Tone, Kazuya; Mahdi Alshahni, Mohamed; Fujisaki, Ryuichi; Makimura, Koichi
2017-01-01
Loop-mediated isothermal amplification (LAMP) is a useful DNA detection method with high specificity and sensitivity. The LAMP reaction is carried out within a short time at a constant temperature without the need for thermal cycling. We developed a LAMP primer set for detecting a wide range of fungi by aligning the sequences of the large subunit ribosomal RNA gene of Candida albicans (Ascomycota), Cryptococcus neoformans (Basidiomycota), and Mucor racemosus (Mucorales). The threshold of C. albicans rDNA as template with our LAMP primer set was in the range of 10-100 copies per a reaction. In this study, we evaluated the correlation between colony forming units (CFU) and LAMP detection rate using the LAMP method for environmental fungi. The LAMP method should be a useful means of detecting fungi in indoor environments, disaster areas, or even in confined manned spacecraft to prevent allergies or infections caused by fungi.
Niessen, Ludwig; Bechtner, Julia; Fodil, Sihem; Taniwaki, Marta H; Vogel, Rudi F
2018-02-02
Aflatoxins can be produced by 21 species within sections Flavi (16 species), Ochraceorosei (2), and Nidulantes (3) of the fungal genus Aspergillus. They pose risks to human and animal health due to high toxicity and carcinogenicity. Detecting aflatoxin producers can help to assess toxicological risks associated with contaminated commodities. Species specific molecular assays (PCR and LAMP) are available for detection of major producers, but fail to detect species of minor importance. To enable rapid and sensitive detection of several aflatoxin producing species in a single analysis, a nor1 gene-specific LAMP assay was developed. Specificity testing showed that among 128 fungal species from 28 genera, 15 aflatoxigenic species in section Flavi were detected, including synonyms of A. flavus and A. parasiticus. No cross reactions were found with other tested species. The detection limit of the assay was 9.03pg of A. parasiticus genomic DNA per reaction. Visual detection of positive LAMP reactions under daylight conditions was facilitated using neutral red to allow unambiguous distinction between positive and negative assay results. Application of the assay to the detection of A. parasiticus conidia revealed a detection limit of 211 conidia per reaction after minimal sample preparation. The usefulness of the assay was demonstrated in the analysis of aflatoxinogenic species in samples of rice, nuts, raisins, dried figs, as well as powdered spices. Comparison of LAMP results with presence/absence of aflatoxins and aflatoxin producing fungi in 50 rice samples showed good correlation between these parameters. Our study suggests that the developed LAMP assay is a rapid, sensitive and user-friendly tool for surveillance and quality control in our food industry. Copyright © 2017 Elsevier B.V. All rights reserved.
Waters, Ryan A.; Fowler, Veronica L.; Armson, Bryony; Nelson, Noel; Gloster, John; Paton, David J.; King, Donald P.
2014-01-01
Rapid, field-based diagnostic assays are desirable tools for the control of foot-and-mouth disease (FMD). Current approaches involve either; 1) Detection of FMD virus (FMDV) with immuochromatographic antigen lateral flow devices (LFD), which have relatively low analytical sensitivity, or 2) portable RT-qPCR that has high analytical sensitivity but is expensive. Loop-mediated isothermal amplification (LAMP) may provide a platform upon which to develop field based assays without these drawbacks. The objective of this study was to modify an FMDV-specific reverse transcription–LAMP (RT-LAMP) assay to enable detection of dual-labelled LAMP products with an LFD, and to evaluate simple sample processing protocols without nucleic acid extraction. The limit of detection of this assay was demonstrated to be equivalent to that of a laboratory based real-time RT-qPCR assay and to have a 10,000 fold higher analytical sensitivity than the FMDV-specific antigen LFD currently used in the field. Importantly, this study demonstrated that FMDV RNA could be detected from epithelial suspensions without the need for prior RNA extraction, utilising a rudimentary heat source for amplification. Once optimised, this RT-LAMP-LFD protocol was able to detect multiple serotypes from field epithelial samples, in addition to detecting FMDV in the air surrounding infected cattle, pigs and sheep, including pre-clinical detection. This study describes the development and evaluation of an assay format, which may be used as a future basis for rapid and low cost detection of FMDV. In addition it provides providing “proof of concept” for the future use of LAMP assays to tackle other challenging diagnostic scenarios encompassing veterinary and human health. PMID:25165973
Code of Federal Regulations, 2010 CFR
2010-01-01
... of Medium Base Compact Fluorescent Lamps W Appendix W to Subpart B of Part 430 Energy DEPARTMENT OF... Consumption of Medium Base Compact Fluorescent Lamps 1. Scope: This appendix covers the test requirements used... rated life, rapid cycle stress, and lamp life of medium base compact fluorescent lamps. 2. Definitions...
Code of Federal Regulations, 2012 CFR
2012-01-01
... of Medium Base Compact Fluorescent Lamps W Appendix W to Subpart B of Part 430 Energy DEPARTMENT OF... Consumption of Medium Base Compact Fluorescent Lamps 1. Scope: This appendix covers the test requirements used... rated life, rapid cycle stress, and lamp life of medium base compact fluorescent lamps. 2. Definitions...
Code of Federal Regulations, 2011 CFR
2011-01-01
... of Medium Base Compact Fluorescent Lamps W Appendix W to Subpart B of Part 430 Energy DEPARTMENT OF... Consumption of Medium Base Compact Fluorescent Lamps 1. Scope: This appendix covers the test requirements used... rated life, rapid cycle stress, and lamp life of medium base compact fluorescent lamps. 2. Definitions...
Code of Federal Regulations, 2014 CFR
2014-01-01
... of Medium Base Compact Fluorescent Lamps W Appendix W to Subpart B of Part 430 Energy DEPARTMENT OF... Consumption of Medium Base Compact Fluorescent Lamps 1. Scope: This appendix covers the test requirements used... rated life, rapid cycle stress, and lamp life of medium base compact fluorescent lamps. 2. Definitions...
46 CFR 32.85-1 - Fireproofing of lamp, oil and paint rooms-T/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Fireproofing of lamp, oil and paint rooms-T/ALL. 32.85-1..., MACHINERY, AND HULL REQUIREMENTS Lamp and Paint Rooms and Similar Compartments on Tankships § 32.85-1 Fireproofing of lamp, oil and paint rooms—T/ALL. Lamp, oil and paint rooms shall be wholly and tightly lined...
46 CFR 32.85-1 - Fireproofing of lamp, oil and paint rooms-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Fireproofing of lamp, oil and paint rooms-T/ALL. 32.85-1..., MACHINERY, AND HULL REQUIREMENTS Lamp and Paint Rooms and Similar Compartments on Tankships § 32.85-1 Fireproofing of lamp, oil and paint rooms—T/ALL. Lamp, oil and paint rooms shall be wholly and tightly lined...
46 CFR 32.85-1 - Fireproofing of lamp, oil and paint rooms-T/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Fireproofing of lamp, oil and paint rooms-T/ALL. 32.85-1..., MACHINERY, AND HULL REQUIREMENTS Lamp and Paint Rooms and Similar Compartments on Tankships § 32.85-1 Fireproofing of lamp, oil and paint rooms—T/ALL. Lamp, oil and paint rooms shall be wholly and tightly lined...
46 CFR 32.85-1 - Fireproofing of lamp, oil and paint rooms-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Fireproofing of lamp, oil and paint rooms-T/ALL. 32.85-1..., MACHINERY, AND HULL REQUIREMENTS Lamp and Paint Rooms and Similar Compartments on Tankships § 32.85-1 Fireproofing of lamp, oil and paint rooms—T/ALL. Lamp, oil and paint rooms shall be wholly and tightly lined...
46 CFR 32.85-1 - Fireproofing of lamp, oil and paint rooms-T/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Fireproofing of lamp, oil and paint rooms-T/ALL. 32.85-1..., MACHINERY, AND HULL REQUIREMENTS Lamp and Paint Rooms and Similar Compartments on Tankships § 32.85-1 Fireproofing of lamp, oil and paint rooms—T/ALL. Lamp, oil and paint rooms shall be wholly and tightly lined...
Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.; Poplawski, Michael E.; Brown, Charles C.
2014-12-01
To date, all three reports in the retail lamps series have focused on basic performance parameters, such as lumen output, efficacy, and color quality. This report goes a step further, examining the photoelectric characteristics (i.e., dimming and flicker) of a subset of lamps from CALiPER Retails Lamps Study 3. Specifically, this report focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers. The results demonstrate notable variation across the various lamps, but little variation between the four dimmers. Overall, the LED lamps: ~tended to have higher relative light outputmore » compared to the incandescent and halogen benchmark at the same dimmer output signal (RMS voltage). The lamps’ dimming curves (i.e., the relationship between control signal and relative light output) ranged from linear to very similar to the square-law curve typical of an incandescent lamp. ~generally exhibited symmetrical behavior—the same dimming curve—when measured proceeding from maximum to minimum or minimum to maximum control signal. ~mostly dimmed below 10% of full light output, with some exceptions for specific lamp and dimmer combinations ~exhibited a range of flicker characteristics, with many comparing favorably to the level typical of a magnetically-ballasted fluorescent lamp through at least a majority of the dimming range. ~ always exceeded the relative (normalized) efficacy over the dimming range of the benchmark lamps, which rapidly decline in efficacy when they are dimmed. This report generally does not attempt to rank the performance of one product compared to another, but instead focuses on the collective performance of the group versus conventional incandescent or halogen lamps, the performance of which is likely to be the baseline for a majority of consumers. Undoubtedly, some LED lamps perform better—or more similar to conventional lamps—than others. Some perform desirably for one characteristic, but not others. Consumers (and specifiers) may have a hard time distinguishing better-performing lamps from one another; at this time, physical experimentation is likely the best evaluation tool.« less
Beissner, Marcus; Phillips, Richard Odame; Battke, Florian; Bauer, Malkin; Badziklou, Kossi; Sarfo, Fred Stephen; Maman, Issaka; Rhomberg, Agata; Piten, Ebekalisai; Frimpong, Michael; Huber, Kristina Lydia; Symank, Dominik; Jansson, Moritz; Wiedemann, Franz Xaver; Banla Kere, Abiba; Herbinger, Karl-Heinz; Löscher, Thomas; Bretzel, Gisela
2015-01-01
Background As the major burden of Buruli ulcer disease (BUD) occurs in remote rural areas, development of point-of-care (POC) tests is considered a research priority to bring diagnostic services closer to the patients. Loop-mediated isothermal amplification (LAMP), a simple, robust and cost-effective technology, has been selected as a promising POC test candidate. Three BUD-specific LAMP assays are available to date, but various technical challenges still hamper decentralized application. To overcome the requirement of cold-chains for transport and storage of reagents, the aim of this study was to establish a dry-reagent-based LAMP assay (DRB-LAMP) employing lyophilized reagents. Methodology/Principal Findings Following the design of an IS2404 based conventional LAMP (cLAMP) assay suitable to apply lyophilized reagents, a lyophylization protocol for the DRB-LAMP format was developed. Clinical performance of cLAMP was validated through testing of 140 clinical samples from 91 suspected BUD cases by routine assays, i.e. IS2404 dry-reagent-based (DRB) PCR, conventional IS2404 PCR (cPCR), IS2404 qPCR, compared to cLAMP. Whereas qPCR rendered an additional 10% of confirmed cases and samples respectively, case confirmation and positivity rates of DRB-PCR or cPCR (64.84% and 56.43%; 100% concordant results in both assays) and cLAMP (62.64% and 52.86%) were comparable and there was no significant difference between the sensitivity of the assays (DRB PCR and cPCR, 86.76%; cLAMP, 83.82%). Likewise, sensitivity of cLAMP (95.83%) and DRB-LAMP (91.67%) were comparable as determined on a set of 24 samples tested positive in all routine assays. Conclusions/Significance Both LAMP formats constitute equivalent alternatives to conventional PCR techniques. Provided the envisaged availability of field friendly DNA extraction formats, both assays are suitable for decentralized laboratory confirmation of BUD, whereby DRB-LAMP scores with the additional advantage of not requiring cold-chains. As validation of the assays was conducted in a third-level laboratory environment, field based evaluation trials are necessary to determine the clinical performance at peripheral health care level. PMID:26566026
Mercury Flow Through the Mercury-Containing Lamp Sector of the Economy of the United States
Goonan, Thomas G.
2006-01-01
Introduction: This Scientific Investigations Report examines the flow of mercury through the mercury-containing lamp sector of the U.S. economy in 2001 from lamp manufacture through disposal or recycling. Mercury-containing lamps illuminate commercial and industrial buildings, outdoor areas, and residences. Mercury is an essential component in fluorescent lamps and high-intensity discharge lamps (high-pressure sodium, mercury-vapor, and metal halide). A typical fluorescent lamp is composed of a phosphor-coated glass tube with electrodes located at either end. Only a very small amount of the mercury is in vapor form. The remainder of the mercury is in the form of either liquid mercury metal or solid mercury oxide (mercury oxidizes over the life of the lamp). When voltage is applied, the electrodes energize the mercury vapor and cause it to emit ultraviolet energy. The phosphor coating absorbs the ultraviolet energy, which causes the phosphor to fluoresce and emit visible light. Mercury-containing lamps provide more lumens per watt than incandescent lamps and, as a result, require from three to four times less energy to operate. Mercury is persistent and toxic within the environment. Mercury-containing lamps are of environmental concern because they are widely distributed throughout the environment and are easily broken in handling. The magnitude of lamp sector mercury emissions, estimated to be 2.9 metric tons per year (t/yr), is small compared with the estimated mercury losses of the U.S. coal-burning and chlor-alkali industries, which are about 70 t/yr and about 90 t/yr, respectively.
NASA Astrophysics Data System (ADS)
Baadj, S.; Harrache, Z.; Belasri, A.
2013-12-01
The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl2 mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl2 percentage in the Xe/Cl2 gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionic processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-24
... Conservation Program: Framework Document for General Service Fluorescent Lamps and Incandescent Reflector Lamps... public meeting and availability of the framework document on general service fluorescent lamps and incandescent reflector lamps energy conservation standards in the Federal Register. This notice announces that...
Vibration-Resistant Support for Halide Lamps
NASA Technical Reports Server (NTRS)
Kiss, J.
1987-01-01
Lamp envelope protected against breakage. Old and new mounts for halide arc lamp sealed in housing with parabolic refector and quartz window. New version supports lamp with compliant garters instead of rigid brazed joint at top and dimensionally unstable finger stock at bottom.
Halogen lamp experiment, HALEX
NASA Technical Reports Server (NTRS)
Schmitt, G.; Stapelmann, J.
1986-01-01
The main purpose of the Halogen Lamp Experiment (HALEX) was to investigate the operation of a halogen lamp during an extended period in a microgravity environment and to prove its behavior in space. The Mirror Heating Facilities for Crystal Growth and Material Science Experiments in space relies on one or two halogen lamps as a furnace to melt the specimens. The HALEX aim is to verify: full power operation of a halogen lamp for a period of about 60 hours; achievement of about 10% of its terrestrial life span; and operation of the halogen lamp under conditions similar to furnace operation.
Estimation of mercury amount in the components of spent U-type lamp.
Rhee, Seung-Whee
2017-05-01
Spent U-type lamps are strongly encouraged to be separately managed in Korea, because U-type lamps are categorized as a household waste and thereby could not be managed properly. Determination of mercury amount in the components of U-type lamp, such as plastics, glass tube and phosphor powder from 3 U-type lamp manufacturers (A, B and C), is carried out to estimate the mercury content in spent U-type lamps. Regardless of lamp manufacturers, the portion of mercury in phosphor powder was higher than 90%, but that in plastics and others was less than 1%. At an air flow rate of 1.0 L/min, the range of the initial mercury concentration in vapor phase for U-type lamp was between 849 and 2076 µg/m 3 from 3 companies. The estimated mercury amount in vapor phase of U-type lamp was in the range from 0.206 mg for company A to 0.593 mg for company B. And the portion of mercury in vapor phase in the total amount of mercury was estimated in the range from 3.0% for company A to 6.7% for company B. Hence, it is desirable to get rid of mercury from phosphor powder in order to perform U-type lamps recycling.
Immunocapture loop-mediated isothermal amplification assays for the detection of canine parvovirus.
Sun, Yu-Ling; Yen, Chon-Ho; Tu, Ching-Fu
2017-11-01
A loop-mediated isothermal amplification (LAMP) assay was used for rapid canine parvovirus (CPV) diagnosis. To reduce the time required and increase the sensitivity of the assay, an immunocapture (IC) technique was developed in this study to exclude the DNA extraction step in molecular diagnostic procedures for CPV. A polyclonal rabbit anti-CPV serum was produced against VP2-EpC that was cloned via DNA recombination. The polyclonal anti-VP2-EpC serum was used for virus capture to prepare microtubes. IC-LAMP was performed to amplify a specific CPV target gene sequence from the CPV viral particles that were captured on the microtubes, and the amplicons were analyzed using agarose electrophoresis or enzyme-linked immunosorbent assay (IC-LAMP-ELISA) and lateral-flow dipstick (IC-LAMP-LFD). The detection sensitivities of IC-LAMP, IC-LAMP-ELISA, and IC-LAMP-LFD were 10 -1 , 10 -1 , and 10 -1 TCID 50 /mL, respectively. Using the IC-LAMP-ELISA and IC-LAMP-LFD assays, the complete CPV diagnostic process can be achieved within 1.5h. Both of the developed IC-LAMP-based assays are simple, direct visual and efficient techniques that are applicable to the detection of CPV. Copyright © 2017 Elsevier B.V. All rights reserved.
Gadkar, Vijay J; Goldfarb, David M; Gantt, Soren; Tilley, Peter A G
2018-04-03
Loop-mediated isothermal amplification (LAMP) is an isothermal nucleic acid amplification (iNAAT) technique known for its simplicity, sensitivity and speed. Its low-cost feature has resulted in its wide scale application, especially in low resource settings. The major disadvantage of LAMP is its heavy reliance on indirect detection methods like turbidity and non-specific dyes, which often leads to the detection of false positive results. In the present work, we have developed a direct detection approach, whereby a labelled loop probe quenched in its unbound state, fluoresces only when bound to its target (amplicon). Henceforth, referred to as Fluorescence of Loop Primer Upon Self Dequenching-LAMP (FLOS-LAMP), it allows for the sequence-specific detection of LAMP amplicons. The FLOS-LAMP concept was validated for rapid detection of the human pathogen, Varicella-zoster virus, from clinical samples. The FLOS-LAMP had a limit of detection of 500 copies of the target with a clinical sensitivity and specificity of 96.8% and 100%, respectively. The high level of specificity is a major advance and solves one of the main shortcomings of the LAMP technology, i.e. false positives. Self-quenching/de-quenching probes were further used with other LAMP primer sets and different fluorophores, thereby demonstrating its versatility and adaptability.
Fallahi, Shirzad; Mazar, Zahra Arab; Ghasemian, Mehrdad; Haghighi, Ali
2015-05-01
To compare analytical sensitivity and specificity of a newly described DNA amplification technique, LAMP and nested PCR assay targeting the RE and B1 genes for the detection of Toxoplasma gondii (T. gondii) DNA. The analytical sensitivity of LAMP and nested-PCR was obtained against10-fold serial dilutions of T. gondii DNA ranging from 1 ng to 0.01 fg. DNA samples of other parasites and human chromosomal DNA were used to determine the specificity of molecular assays. After testing LAMP and nested-PCR in duplicate, the detection limit of RE-LAMP, B1-LAMP, RE-nested PCR and B1-nested PCR assays was one fg, 100 fg, 1 pg and 10 pg of T. gondii DNA respectively. All the LAMP assays and nested PCRs were 100% specific. The RE-LAMP assay revealed the most sensitivity for the detection of T. gondii DNA. The obtained results demonstrate that the LAMP technique has a greater sensitivity for detection of T. gondii. Furthermore, these findings indicate that primers based on the RE are more suitable than those based on the B1 gene. However, the B1-LAMP assay has potential as a diagnostic tool for detection of T. gondii. Copyright © 2015 Hainan Medical College. Production and hosting by Elsevier B.V. All rights reserved.
Optimization of lamp arrangement in a closed-conduit UV reactor based on a genetic algorithm.
Sultan, Tipu; Ahmad, Zeshan; Cho, Jinsoo
2016-01-01
The choice for the arrangement of the UV lamps in a closed-conduit ultraviolet (CCUV) reactor significantly affects the performance. However, a systematic methodology for the optimal lamp arrangement within the chamber of the CCUV reactor is not well established in the literature. In this research work, we propose a viable systematic methodology for the lamp arrangement based on a genetic algorithm (GA). In addition, we analyze the impacts of the diameter, angle, and symmetry of the lamp arrangement on the reduction equivalent dose (RED). The results are compared based on the simulated RED values and evaluated using the computational fluid dynamics simulations software ANSYS FLUENT. The fluence rate was calculated using commercial software UVCalc3D, and the GA-based lamp arrangement optimization was achieved using MATLAB. The simulation results provide detailed information about the GA-based methodology for the lamp arrangement, the pathogen transport, and the simulated RED values. A significant increase in the RED values was achieved by using the GA-based lamp arrangement methodology. This increase in RED value was highest for the asymmetric lamp arrangement within the chamber of the CCUV reactor. These results demonstrate that the proposed GA-based methodology for symmetric and asymmetric lamp arrangement provides a viable technical solution to the design and optimization of the CCUV reactor.
Effects of wavelength and water quality on photodegradation of N-Nitrosodimethylamine (NDMA).
Sakai, Hiroshi; Takamatsu, Tatsuro; Kosaka, Koji; Kamiko, Naoyuki; Takizawa, Satoshi
2012-10-01
N-Nitrosodimethylamine (NDMA) is a potent carcinogen that yields a cancer risk of 10(-6) at concentrations as low as 0.7 ng L(-1). Tentative guideline values are set at 3 ng L(-1) in California, USA; 9 ng L(-1) in Ontario, Canada; 40 ng L(-1) nationwide in Canada; and 100 ng L(-1) by the World Health Organization. NDMA is a great concern in treating reclaimed water as well as drinking water. UV degradation can be considered effective degradation method. A 1-log reduction of NDMA is achieved by 1000 mJ cm(-2) of a 254-nm low pressure (LP) mercury UV lamp. However, a higher degradation efficiency than that provided by LP lamps is desired in practical treatment. In this study, the effects of wavelength and water quality were investigated to achieve higher degradation efficiency. The effects of wavelength were examined by comparing three UV lamps: a 222-nm Kr Cl Excimer UV lamp, a 254-nm LP mercury UV lamp, and a 230- to 270-nm filtered medium pressure (FMP) mercury UV lamp. The 222-nm lamp and FMP lamp achieved 4 times and 2.8 times higher degradation efficiency, respectively, than the conventional 254-nm LP lamp. Effects on water quality were also simulated by using absorption spectrum data of nitrate solutions and process water from a drinking-water treatment plant. In the simulation, the 222-nm lamp was affected by UV-absorbing compounds in the water, whereas the FMP lamp showed more stable degradation efficiency. Appropriate use of these three types of lamps could enhance the efficiency of degradation of NDMA. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jozwiak, Zbigniew Boguslaw
1995-01-01
Ethylene is an important auto-catalytic plant growth hormone. Removal of ethylene from the atmosphere surrounding ethylene-sensitive horticultural products may be very beneficial, allowing an extended period of storage and preventing or delaying the induction of disorders. Various ethylene removal techniques have been studied and put into practice. One technique is based on using low pressure mercury ultraviolet lamps as a source of photochemical energy to initiate chemical reactions that destroy ethylene. Although previous research showed that ethylene disappeared in experiments with mercury ultraviolet lamps, the reactions were not described and the actual cause of ethylene disappearance remained unknown. Proposed causes for this disappearance were the direct action of ultraviolet rays on ethylene, reaction of ethylene with ozone (which is formed when air or gas containing molecular oxygen is exposed to radiation emitted by this type of lamp), or reactions with atomic oxygen leading to formation of ozone. The objective of the present study was to determine the set of physical and chemical actions leading to the disappearance of ethylene from artificial storage atmosphere under conditions of ultraviolet irradiation. The goal was achieved by developing a static chemical model based on the physical properties of a commercially available ultraviolet lamp, the photochemistry of gases, and the kinetics of chemical reactions. The model was used to perform computer simulations predicting time dependent concentrations of chemical species included in the model. Development of the model was accompanied by the design of a reaction chamber used for experimental verification. The model provided a good prediction of the general behavior of the species involved in the chemistry under consideration; however the model predicted lower than measured rate of ethylene disappearance. Some reasons for the model -experiment disagreement are radiation intensity averaging, the experimental technique, mass transfer in the chamber, and incompleteness of the set of chemical reactions included in the model. The work is concluded with guidelines for development of a more complex mathematical model that includes elements of mass transfer inside the reaction chamber, and uses a three dimensional approach to distribute radiation from the low pressure mercury ultraviolet tube.
Frequency Domain Fluorimetry Using a Mercury Vapor Lamp
2009-04-07
independence from light scatter and excitation/emission intensity variations in order to extract the sample’s fluorescent lifetime. Mercury vapor lamps ...the modulation amplitude of the lamp , An, via: max 0 1 ( ) sin(2 ) n fluorescence n n n I t B nf tπ θ = ∝ +∑ (8... lamp is estimated by assuming the lamp is emitting as a point source of uniform intensity into the lower hemisphere and has a reflector collecting
Lee, DoKyung; Kim, Eun Jin; Kilgore, Paul E; Kim, Soon Ae; Takahashi, Hideyuki; Ohnishi, Makoto; Anh, Dang Duc; Dong, Bai Qing; Kim, Jung Soo; Tomono, Jun; Miyamoto, Shigehiko; Notomi, Tsugunori; Kim, Dong Wook; Seki, Mitsuko
2015-01-01
Neisseria meningitidis (Nm) is a leading causative agent of bacterial meningitis in humans. Traditionally, meningococcal meningitis has been diagnosed by bacterial culture. However, isolation of bacteria from patients' cerebrospinal fluid (CSF) is time consuming and sometimes yields negative results. Recently, polymerase chain reaction (PCR)-based diagnostic methods of detecting Nm have been considered the gold standard because of their superior sensitivity and specificity compared with culture. In this study, we developed a loop-mediated isothermal amplification (LAMP) method and evaluated its ability to detect Nm in cerebrospinal fluid (CSF). We developed a meningococcal LAMP assay (Nm LAMP) that targets the ctrA gene. The primer specificity was validated using 16 strains of N. meningitidis (serogroup A, B, C, D, 29-E, W-135, X, Y, and Z) and 19 non-N. meningitidis species. Within 60 min, the Nm LAMP detected down to ten copies per reaction with sensitivity 1000-fold more than that of conventional PCR. The LAMP assays were evaluated using a set of 1574 randomly selected CSF specimens from children with suspected meningitis collected between 1998 and 2002 in Vietnam, China, and Korea. The LAMP method was shown to be more sensitive than PCR methods for CSF samples (31 CSF samples were positive by LAMP vs. 25 by PCR). The detection rate of the LAMP method was substantially higher than that of the PCR method. In a comparative analysis of the PCR and LAMP assays, the clinical sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP assay were 100%, 99.6%, 80.6%, and 100%, respectively. Compared to PCR, LAMP detected Nm with higher analytical and clinical sensitivity. This sensitive and specific LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 57.17010 - Electric lamps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric lamps. 57.17010 Section 57.17010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE....17010 Electric lamps. Individual electric lamps shall be carried for illumination by all persons...
30 CFR 57.17010 - Electric lamps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric lamps. 57.17010 Section 57.17010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE....17010 Electric lamps. Individual electric lamps shall be carried for illumination by all persons...
30 CFR 57.17010 - Electric lamps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric lamps. 57.17010 Section 57.17010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE....17010 Electric lamps. Individual electric lamps shall be carried for illumination by all persons...
30 CFR 57.17010 - Electric lamps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric lamps. 57.17010 Section 57.17010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE....17010 Electric lamps. Individual electric lamps shall be carried for illumination by all persons...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 57.17010 - Electric lamps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric lamps. 57.17010 Section 57.17010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE....17010 Electric lamps. Individual electric lamps shall be carried for illumination by all persons...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... incandescent lamp envelope manufacturing subcategory. 426.120 Section 426.120 Protection of Environment... POINT SOURCE CATEGORY Incandescent Lamp Envelope Manufacturing Subcategory § 426.120 Applicability; description of the incandescent lamp envelope manufacturing subcategory. The provisions of this subpart are...
Code of Federal Regulations, 2014 CFR
2014-07-01
... incandescent lamp envelope manufacturing subcategory. 426.120 Section 426.120 Protection of Environment... POINT SOURCE CATEGORY Incandescent Lamp Envelope Manufacturing Subcategory § 426.120 Applicability; description of the incandescent lamp envelope manufacturing subcategory. The provisions of this subpart are...
Code of Federal Regulations, 2012 CFR
2012-07-01
... incandescent lamp envelope manufacturing subcategory. 426.120 Section 426.120 Protection of Environment... POINT SOURCE CATEGORY Incandescent Lamp Envelope Manufacturing Subcategory § 426.120 Applicability; description of the incandescent lamp envelope manufacturing subcategory. The provisions of this subpart are...
Code of Federal Regulations, 2011 CFR
2011-07-01
... incandescent lamp envelope manufacturing subcategory. 426.120 Section 426.120 Protection of Environment... CATEGORY Incandescent Lamp Envelope Manufacturing Subcategory § 426.120 Applicability; description of the incandescent lamp envelope manufacturing subcategory. The provisions of this subpart are applicable to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... incandescent lamp envelope manufacturing subcategory. 426.120 Section 426.120 Protection of Environment... CATEGORY Incandescent Lamp Envelope Manufacturing Subcategory § 426.120 Applicability; description of the incandescent lamp envelope manufacturing subcategory. The provisions of this subpart are applicable to...
Rapid and visual detection of Leptospira in urine by LigB-LAMP assay with pre-addition of dye.
Ali, Syed Atif; Kaur, Gurpreet; Boby, Nongthombam; Sabarinath, T; Solanki, Khushal; Pal, Dheeraj; Chaudhuri, Pallab
2017-12-01
Leptospirosis is considered to be the most widespread zoonotic disease caused by pathogenic species of Leptospira. The present study reports a novel set of primers targeting LigB gene for visual detection of pathogenic Leptospira in urine samples through Loop-mediated isothermal amplification (LAMP). The results were recorded by using Hydroxyl napthol blue (HNB), SYBR GREEN I and calcein. Analytical sensitivity of LAMP was as few as 10 leptospiral organisms in spiked urine samples from cattle and dog. LigB gene based LAMP, termed as LigB-LAMP, was found 10 times more sensitive than conventional PCR. The diagnostic specificity of LAMP was 100% when compared to SYBR green qPCR for detection of Leptospira in urine samples. Though qPCR was found more sensitive, the rapidity and simplicity in setting LAMP test followed by visual detection of Leptospira infection in clinical samples makes LigB-LAMP an alternative and favourable diagnostic tool in resource poor setting. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zhang, Wei; Chen, Chuanhui; Cui, Jian; Bai, Wei; Zhou, Jing
2015-01-01
The present study explores the application of LAMP for rapid diagnosis of pathogenic bacteria in clinical sputum specimens of AECOPD as compared with conventional sputum culturing method. 120 sputum specimens of AECOPD patients, 46 sputum specimens of healthy controls, as well as 166 serum specimens as negative controls, were evaluated by LAMP assay using primers of eight typical respiratory pathogens. No cross-reactivity was observed in these negative control species using LAMP assay. The lower detection limit of LAMP assay was approximately 10(3) copies. 25 cases (20.8%) were detected at least one positive bacteria species by conventional sputum culturing method, while 73 cases (60.8%) were tested positive in LAMP assay. Moreover, compared with sputum culture, bacterial titers results of LAMP assay were more consistent with FEV1/FVC value of AECOPD patients. These results indicated that the sensitivity of LAMP assay was significantly higher than that of sputum culturing method.
COS/FUV Mapping of Stray PtNe Lamp Light Through FCA
NASA Astrophysics Data System (ADS)
Oliveira, Cristina
2010-09-01
This program determines which cross-dispersion locations lead to wavecal lamp {PtNe} light leaking through the flat-field calibration aperture {FCA}. This unexpected effect, observed initially in program 12096, led to a shut down of the COS/FUV detector due to a global count rate violation in Segment A of the G140L/1230 setting. Detector? threshold ?is ?600,000 ?FEC ?counts ?in? 10 seconds ?on each ?segment. ?If ?this ?level? is ?exceeded, ?the? detector? shuts ?down? the ?HV.In program 12096, for the G140L/1230 setting, at +6" from the nominal position in the cross-dispersion direction, 180,000 cts/sec were observed through the FCA in Segment A, and 49,000 cts/sec in Segment B {PtNe/FCA}. The corresponding wavecal count rate {PtNe/WCA} is 685 cts/sec in Segment A, implying that there is a scale factor of 263 between the FCA and WCA count rates. This scale factor could not be verified for Segment B, given that the PtNe lamp does not produce counts at the short wavelengths seen by G140L/1230/FUVB. However, this scaling factor is expected to be the same for both segments.The scaling factor derived from program 12096 is then used to predict the FCA count rates seen with all the gratings, in off-nominal positions where light might leak through the FCA in the current program.There is no light leak between the nominal position and positions up to and including +3" {at least not in Mar 2010 when program 12096 executed}, but somewhere above +3" and certainly at +6" the PtNe light starts leaking through the FCA.Light is not predicted to leak at negative POS-TARG positions from the nominal, and the purpose of this program is to verify that as well.Visits 1N to 6N take data at positions from +1.0" to +6.0", while visits 1S to 6S take data at positions from -1.0" to -6.0". Visits 10 through 13 take data at the nominal position, 0.0".At each position in the detector data is taken with the following settings:G130M/1055/1291/1327, G160M/1577/1623, and G140L/1280/1105, in this order.LAMP2 with CURRENT=LOW is used in all of these visits. In addition, at each position, one exposure with LAMP1 CURRENT=MED is also taken with the G130M/1055 setting, which leads to total counts in 10 sec more than a factor of 10 below the 600,000 limit. This exposure is used so that the ratio of LAMP1/MED to LAMP2/LOW can be calculated for the FCA at each position {in conjunction with the data obtained in visits 11, 12, and 13; see below}. In addition, the G130M/1055 exposures with LAMP1/MED and LAMP2/LOW will be used to determine if the lamp spot size is changing at each position.Depending on the total counts estimated for each setting, either a typical wave exposure is taken or special flash commands are used. Details are given in each visit.Exposures obtained with LAMP1/CURRENT=LOW are expected to have a 20% smaller count rate than exposures obtained with LAMP1/CURRENT=MED. Exposures obtained with LAMP2/CURRENT=MED are expected to have count rates similar to those obtained with LAMP1/CURRENT=MED, and exposures obtained with LAMP2/CURRENT=LOW are expected to have a count rate which is 1/7 of that obtainedwith LAMP2/CURRENT=MED.VISIT 10 OBTAINS LAMP1/CURRENT=MED+ LOW SPECTRA AT ALL THE M SETTINGS USED IN THIS PROGRAM, AT THE NOMINAL POSITION {0.0"}.VISIT 11 OBTAINS LAMP2/CURRENT=MED SPECTRA AT ALL THE M SETTINGS USED IN THIS PROGRAM, AT THE NOMINAL POSITION {0.0"}.VISIT 12 OBTAINS LAMP2/CURRENT=LOW SPECTRA AT ALL THE M SETTINGS USED IN THIS PROGRAM, AT THE NOMINAL POSITION {0.0"}.VISIT 13 OBTAINS LAMP1/CURRENT=MED, LOW AND LAMP2/CURRENT=MED, LOW SPECTRA AT ALL OF THE L SETTINGS USED IN THIS PROGRAM, AT THE NOMINAL POSITION {0.0"}.THE GOAL OF THESE VISITS IS TO DETERMINE THE RATIOS OF THE DIFFERENT LAMP SETTINGS AT DIFFERENT WAVELENGTHS, TO HELP IN ANALYZING THE DATA OBTAINED IN VISITS WHERE ONLY LAMP2/LOW IS USED.ALSO, THESE DATA WILL BE USED TO PREDICT WHAT THE COUNTS WOULD BE WITH G140L/1280/LAMP1/MED AT THE +6.0" POSITION {VIS6N, WHERE LAMP2/LOW IS USED}. THESE COUNTS WILL BE COMPARED WITH THE COUNTS OBTAINED IN PROGRAM 12096 WITH G140L/1230/LAMP1/MED, MORE THAN ONE YEAR AGO, TO LOOK FOR VARIABILITY, POSSIBLY INDICATING CHANGES TO THE LAMP SPOT SIZE.Visits 10 through 13, all executed at the nominal position, pose no safety concerns.CONSTRAINTS:- Visits 1N, 2N, 3N can be executed back to back as no light is expected to leak through the FCA. Visit 1N should execute before visit 2N, which should execute before visit 3N.- Visits 1S, 2S, and 3S can be executed back to back and do not have constraints relative to the other visits. Visit 1S should execute before visit 2S, which should execute before visit 3S- Visits 10, 11, 12, and 13 {data obtained at nominal position}, can also be executed back to back and have no constraints relative to other visits. However, these visits should be scheduled as soon as possible, because results of data anaysis will be used to inform execution of program 12678.- There should be an interval of at least two days between any of the visits mentioned above and the other visits in this program {4N, 5N, 6N, 4S, 5S, 6S} which could see light leaking through the FCA.- Visits 4S and 4N can be scheduled in the same week, but they don't need to be.- Visits 5S and 5N can be scheduled in the same week, but they don't need to be.- There should be an interval of at least 3 weeks between visit 4N and visit 5N.- Visits 6S and 6N can be scheduled in the same week, but they don't need to be.- There should be an interval of at least 3 weeks between visit 5N and visit 6N.- Visits 1S through 5S should be scheduled as soon as possible, the same is true for visits 1N to 4N.
Tang, Fu-Lei; Erion, Joanna R.; Tian, Yun; Liu, Wei; Yin, Dong-Min; Ye, Jian; Tang, Baisha; Mei, Lin
2015-01-01
Vacuolar protein sorting-35 (VPS35) is essential for endosome-to-Golgi retrieval of membrane proteins. Mutations in the VPS35 gene have been identified in patients with autosomal dominant PD. However, it remains poorly understood if and how VPS35 deficiency or mutation contributes to PD pathogenesis. Here we provide evidence that links VPS35 deficiency to PD-like neuropathology. VPS35 was expressed in mouse dopamine (DA) neurons in substantia nigra pars compacta (SNpc) and STR (striatum)—regions that are PD vulnerable. VPS35-deficient mice exhibited PD-relevant deficits including accumulation of α-synuclein in SNpc-DA neurons, loss of DA transmitter and DA neurons in SNpc and STR, and impairment of locomotor behavior. Further mechanical studies showed that VPS35-deficient DA neurons or DA neurons expressing PD-linked VPS35 mutant (D620N) had impaired endosome-to-Golgi retrieval of lysosome-associated membrane glycoprotein 2a (Lamp2a) and accelerated Lamp2a degradation. Expression of Lamp2a in VPS35-deficient DA neurons reduced α-synuclein, supporting the view for Lamp2a as a receptor of chaperone-mediated autophagy to be critical for α-synuclein degradation. These results suggest that VPS35 deficiency or mutation promotes PD pathogenesis and reveals a crucial pathway, VPS35-Lamp2a-α-synuclein, to prevent PD pathogenesis. SIGNIFICANCE STATEMENT VPS35 is a key component of the retromer complex that is essential for endosome-to-Golgi retrieval of membrane proteins. Mutations in the VPS35 gene have been identified in patients with PD. However, if and how VPS35 deficiency or mutation contributes to PD pathogenesis remains unclear. We demonstrated that VPS35 deficiency or mutation (D620N) in mice leads to α-synuclein accumulation and aggregation in the substantia nigra, accompanied with DA neurodegeneration. VPS35-deficient DA neurons exhibit impaired endosome-to-Golgi retrieval of Lamp2a, which may contribute to the reduced α-synuclein degradation through chaperone-mediated autophagy. These results suggest that VPS35 deficiency or mutation promotes PD pathogenesis, and reveals a crucial pathway, VPS35-Lamp2a-α-synuclein, to prevent PD pathogenesis. PMID:26203154
Fischbach, Jens; Xander, Nina Carolin; Frohme, Marcus; Glökler, Jörn Felix
2015-04-01
The need for simple and effective assays for detecting nucleic acids by isothermal amplification reactions has led to a great variety of end point and real-time monitoring methods. Here we tested direct and indirect methods to visualize the amplification of potato spindle tuber viroid (PSTVd) by loop-mediated isothermal amplification (LAMP) and compared features important for one-pot in-field applications. We compared the performance of magnesium pyrophosphate, hydroxynaphthol blue (HNB), calcein, SYBR Green I, EvaGreen, and berberine. All assays could be used to distinguish between positive and negative samples in visible or UV light. Precipitation of magnesium-pyrophosphate resulted in a turbid reaction solution. The use of HNB resulted in a color change from violet to blue, whereas calcein induced a change from orange to yellow-green. We also investigated berberine as a nucleic acid-specific dye that emits a fluorescence signal under UV light after a positive LAMP reaction. It has a comparable sensitivity to SYBR Green I and EvaGreen. Based on our results, an optimal detection method can be chosen easily for isothermal real-time or end point screening applications.
Comparative studies on dimming capabilities of retrofit LED lamps
NASA Astrophysics Data System (ADS)
Ionescu, Ciprian; Vasile, Alexandru; Codreanu, Norocel; Negroiu, Rodica
2016-12-01
These days many variants for lighting systems are available on the market, and new solutions are about to emerge. Most of the new lamps are offered in form to be retrofitted to existing sockets and luminaires. In this paper, are presented some systematically investigations on different lamps as LEDs, Compact Fluorescent Lamps (CFLs), tungsten, and new available Cold Cathode Fluorescent Lamps (CCFLs), regarding the light level, dimming performances and also the resulting flicker and power distortion performances. The light level was expressed by the illuminance level, measured for all lamps in the same conditions, at the same distance and on the same surface represented by the photometer probe.
[Remote Slit Lamp Microscope Consultation System Based on Web].
Chen, Junfa; Zhuo, Yong; Liu, Zuguo; Chen, Yanping
2015-11-01
To realize the remote operation of the slit lamp microscope for department of ophthalmology consultation, and visual display the real-time status of remote slit lamp microscope, a remote slit lamp microscope consultation system based on B/S structure is designed and implemented. Through framing the slit lamp microscope on the website system, the realtime acquisition and transmission of remote control and image data is realized. The three dimensional model of the slit lamp microscope is established and rendered on the web by using WebGL technology. The practical application results can well show the real-time interactive of the remote consultation system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerke, Brian F.; Ngo, Allison T.; Alstone, Andrea L.
2014-10-14
In recent years, household LED light bulbs (LED A lamps) have undergone a dramatic price decline. Since late 2011, we have been collecting data, on a weekly basis, for retail offerings of LED A lamps on the Internet. The resulting data set allows us to track the recent price decline in detail. LED A lamp prices declined roughly exponentially with time in 2011-2014, with decline rates of 28percent to 44percent per year depending on lumen output, and with higher-lumen lamps exhibiting more rapid price declines. By combining the Internet price data with publicly available lamp shipments indices for the USmore » market, it is also possible to correlate LED A lamp prices against cumulative production, yielding an experience curve for LED A lamps. In 2012-2013, LED A lamp prices declined by 20-25percent for each doubling in cumulative shipments. Similar analysis of historical data for other lighting technologies reveals that LED prices have fallen significantly more rapidly with cumulative production than did their technological predecessors, which exhibited a historical decline of 14-15percent per doubling of production.« less
CALiPER Application Summary Report 21. Linear (T8) LED Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-03-01
This report focuses on the bare lamp performance of 31 linear LED lamps intended as an alternative to T8 fluorescent lamps. Data obtained in accordance with IES LM-79-08 indicated that the mean efficacy is similar to that of fluorescent lamps, but that lumen output is often much lower. This presents a situation where something must change in order for energy savings and equivalent illumination levels to be achieved simultaneously. In this case, the luminous intensity distribution of all the tested lamps was directional or semi-directional, rather than omnidirectional. Also discussed in this report are several issues related to the electricalmore » configuration of the lamps, such as the required socket types and power feed location. While no configuration is necessarily better, the multitude of options can make specifying and installing linear LED lamps more difficult, with the potential for safety issues. Similarly, the variety of color and power quality attributes adds a layer of complexity to the specification process. Many products offered good or excellent quality attributes, but some did not and thus could be perceived as inferior to fluorescent lamps in some installations.« less
[Study on the discharge properties of xeon flash lamp and experimental measurement].
Zhao, You-Quan; Miao, Pei-Liang; He, Feng; Gu, Jian; Zhai, Rui-Wei
2014-07-01
The Xenon flash lamp is a new type of light source for analytical instrument. The present paper analyzed the discharge process of xenon flash lamp, presented the discharge test system, and conducted experimental measurement of the voltage, current and optical pulse signal in the process of discharge. The results show that in the preliminary discharge, the free electron concentration was at a low level, so the energy was at a low level, then following the gas discharge, numerous free electrons formed in the lamp, resultin in the increase in the concentration of free electrons, therefore discharge current rised rapidly and voltage reduced. The lamp released photons to generate light pulse in the moment of ionic recombination, The pulse xenon lamp light energy output and spectral characteristic is related to electron energy in recombination and combination level of xenon, if the input energy and the energy consumption of the xenon lamp is inconsistent, it will lead to repeated capacitor charging and discharging and produce oscillation waveform. This paper is very useful for understanding the process of xenon lamp discharge, optimizing the driver circuit and the production of xenon flash lamp.
RF driven sulfur lamp having driving electrodes which face each other
Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.
1999-06-22
A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.
RF driven sulfur lamp having driving electrodes which face each other
Gabor, George; Orr, Thomas Robert; Greene, Charles Maurice; Crawford, Douglas Gordon; Berman, Samuel Maurice
1999-01-01
A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance.
Damhorst, Gregory L.; Duarte-Guevara, Carlos; Chen, Weili; Ghonge, Tanmay; Cunningham, Brian T.; Bashir, Rashid
2015-01-01
Viral load measurements are an essential tool for the long-term clinical care of hum an immunodeficiency virus (HIV)-positive individuals. The gold standards in viral load instrumentation, however, are still too limited by their size, cost, and sophisticated operation for these measurements to be ubiquitous in remote settings with poor healthcare infrastructure, including parts of the world that are disproportionately affected by HIV infection. The challenge of developing a point-of-care platform capable of making viral load more accessible has been frequently approached but no solution has yet emerged that meets the practical requirements of low cost, portability, and ease-of-use. In this paper, we perform reverse-transcription loop-mediated isothermal amplification (RT-LAMP) on minimally processed HIV-spiked whole blood samples with a microfluidic and silicon microchip platform, and perform fluorescence measurements with a consumer smartphone. Our integrated assay shows amplification from as few as three viruses in a ~ 60 nL RT-LAMP droplet, corresponding to a whole blood concentration of 670 viruses per µL of whole blood. The technology contains greater power in a digital RT-LAMP approach that could be scaled up for the determination of viral load from a finger prick of blood in the clinical care of HIV-positive individuals. We demonstrate that all aspects of this viral load approach, from a drop of blood to imaging the RT-LAMP reaction, are compatible with lab-on-a-chip components and mobile instrumentation. PMID:26705482
Ball, Cameron S; Light, Yooli K; Koh, Chung-Yan; Wheeler, Sarah S; Coffey, Lark L; Meagher, Robert J
2016-04-05
Reverse-transcription-loop-mediated isothermal amplification (RT-LAMP) has frequently been proposed as an enabling technology for simplified diagnostic tests for RNA viruses. However, common detection techniques used for LAMP and RT-LAMP have drawbacks, including poor discrimination capability, inability to multiplex targets, high rates of false positives, and (in some cases) the requirement of opening reaction tubes postamplification. Here, we present a simple technique that allows closed-tube, target-specific detection, based on inclusion of a dye-labeled primer that is incorporated into a target-specific amplicon if the target is present. A short, complementary quencher hybridizes to unincorporated primer upon cooling down at the end of the reaction, thereby quenching fluorescence of any unincorporated primer. Our technique, which we term QUASR (for quenching of unincorporated amplification signal reporters, read "quasar"), does not significantly reduce the amplification efficiency or sensitivity of RT-LAMP. Equipped with a simple LED excitation source and a colored plastic gel filter, the naked eye or a camera can easily discriminate between positive and negative QUASR reactions, which produce a difference in signal of approximately 10:1 without background subtraction. We demonstrate that QUASR detection is compatible with complex sample matrices such as human blood, using a novel LAMP primer set for bacteriophage MS2 (a model RNA virus particle). Furthermore, we demonstrate single-tube duplex detection of West Nile virus (WNV) and chikungunya virus (CHIKV) RNA.
49 CFR 393.25 - Requirements for lamps other than head lamps.
Code of Federal Regulations, 2010 CFR
2010-10-01
... booms, backhoes, and winches) prevents compliance with this paragraph by any required lamp, an auxiliary... SAE J845—Optical Warning Devices for Authorized Emergency, Maintenance and Service Vehicles, May 1997... Authorized Emergency, Maintenance and Service Vehicles, January 2005. Amber gaseous discharge warning lamps...
49 CFR 393.25 - Requirements for lamps other than head lamps.
Code of Federal Regulations, 2011 CFR
2011-10-01
... booms, backhoes, and winches) prevents compliance with this paragraph by any required lamp, an auxiliary... SAE J845—Optical Warning Devices for Authorized Emergency, Maintenance and Service Vehicles, May 1997... Authorized Emergency, Maintenance and Service Vehicles, January 2005. Amber gaseous discharge warning lamps...
146. DETAIL VIEW, LOOKING STRAIGHT ON, OF CAST IRON LAMP ...
146. DETAIL VIEW, LOOKING STRAIGHT ON, OF CAST IRON LAMP STANDARD. THIS AND OTHER LAMP STANDARDS WERE REMOVED FROM THE LAMP COLUMNS ON THE PARAPET WALLS DURING WORLD WAR II AND STORED INSIDE THE DAM (January 1991) - Coolidge Dam, Gila River, Peridot, Gila County, AZ
49 CFR 234.221 - Lamp voltage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Lamp voltage. 234.221 Section 234.221... EMERGENCY NOTIFICATION SYSTEMS Maintenance, Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be maintained at not less than 85 percent of the prescribed rating...
49 CFR 234.221 - Lamp voltage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Lamp voltage. 234.221 Section 234.221... EMERGENCY NOTIFICATION SYSTEMS Maintenance, Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be maintained at not less than 85 percent of the prescribed rating...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-05
... Reflector Lamps, Products Containing Same and Components Thereof; Institution of Investigation AGENCY: U.S... fluorescent reflector lamps, products containing same and components thereof by reason of infringement of... compact fluorescent reflector lamps, products containing same and components thereof by reason of...
49 CFR 234.221 - Lamp voltage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Lamp voltage. 234.221 Section 234.221... EMERGENCY NOTIFICATION SYSTEMS Maintenance, Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be maintained at not less than 85 percent of the prescribed rating...
49 CFR 393.25 - Requirements for lamps other than head lamps.
Code of Federal Regulations, 2013 CFR
2013-10-01
... booms, backhoes, and winches) prevents compliance with this paragraph by any required lamp, an auxiliary... SAE J845—Optical Warning Devices for Authorized Emergency, Maintenance and Service Vehicles, May 1997... Authorized Emergency, Maintenance and Service Vehicles, January 2005. Amber gaseous discharge warning lamps...
49 CFR 393.25 - Requirements for lamps other than head lamps.
Code of Federal Regulations, 2014 CFR
2014-10-01
... booms, backhoes, and winches) prevents compliance with this paragraph by any required lamp, an auxiliary... SAE J845—Optical Warning Devices for Authorized Emergency, Maintenance and Service Vehicles, May 1997... Authorized Emergency, Maintenance and Service Vehicles, January 2005. Amber gaseous discharge warning lamps...
49 CFR 393.25 - Requirements for lamps other than head lamps.
Code of Federal Regulations, 2012 CFR
2012-10-01
... booms, backhoes, and winches) prevents compliance with this paragraph by any required lamp, an auxiliary... SAE J845—Optical Warning Devices for Authorized Emergency, Maintenance and Service Vehicles, May 1997... Authorized Emergency, Maintenance and Service Vehicles, January 2005. Amber gaseous discharge warning lamps...
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2010 CFR
2010-01-01
..., metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp..., current, and waveform) for starting and operating. High intensity discharge lamp means an electric... light is produced by radiation from mercury typically operating at a partial vapor pressure in excess of...
49 CFR 392.33 - Obscured lamps or reflective devices/material.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...
Code of Federal Regulations, 2010 CFR
2010-01-01
... the following reference ballast settings: T10 or T12 lamps are to use 236 volts, 0.43 amps, and 439 ohms; T8 lamps are to use 300 volts, 0.265 amps, and 910 ohms. 4.1.2.22-Foot U-shaped lamps shall be operated using the following reference ballast settings: T12 lamps are to use 236 volts, 0.430 amps, and...
Acute And Long-Term Bioeffects And Lamp Safety
NASA Astrophysics Data System (ADS)
Andersen, F. Alan
1980-10-01
Knowledge of both acute and chronic biological effects is currently used to evaluate lamp safety. In some cases, a quantitative basis for avoiding exposures greater than a certain value can be stated. In other cases, however, only a qualitative estimate of the hazard is available. In a discussion that uses mercury vapor lamps, tanning booths, and sodium vapor lamps as examples, the interplay between the two types of data leading to an evaluation of lamp safety is described.
Brown, Michael C.; Smith, Rex Neal; Badhwar, Anshul K.; Parente, Oscar; Chung, Hyun chul; O’Dell, Donna; Bunch; McGregor, JulieAnne G.; Hogan, Susan L.; Hu, Yichun; Yang, Jia-Jin; Berg, Elisabeth A.; Niles, John; Jennette, J. Charles; Preston, Gloria A.; Falk, Ronald J.
2012-01-01
Lysosomal membrane protein 2 (LAMP-2) is a target of antineutrophil cytoplasmic autoantibodies (ANCA) in addition to the more commonly known targets proteinase 3 and myeloperoxidase. The prevalence of anti–LAMP-2 antibodies and their relationship to disease in ANCA glomerulonephritis are not well described. We measured anti–LAMP-2 reactivity in 680 sera samples (two academic centers) from patients with ANCA glomerulonephritis (n=329); those with ANCA-negative glomerulonephritis (n=104); those with fimbriated, gram-negative Escherichia coli urinary tract infection (n=104); disease controls (n=19); and healthy volunteers (n=124). With levels in healthy controls used to define a reference range, anti–LAMP-2 reactivity was present in 21% of ANCA sera from two of the centers; reactivity was present in 16% of the control group with urinary tract infection. Western blotting and immunofluorescence microscopy did not verify positivity. Titers of anti-myeloperoxidase and anti–proteinase 3 antibodies were 1500-fold and 10,000-fold higher than anti–LAMP-2 titers, respectively. There was no correlation between anti–LAMP-2 antibodies and disease activity. Furthermore, Wistar Kyoto rats injected with anti–LAMP-2 antibodies did not develop glomerulonephritis. In conclusion, antibodies that react with LAMP-2 may exist at very low titers in a minority of patients with ANCA disease. These data do not support a mechanistic relationship between anti–LAMP-2 antibodies and ANCA glomerulonephritis. PMID:22021709
BAD-LAMP controls TLR9 trafficking and signalling in human plasmacytoid dendritic cells.
Combes, Alexis; Camosseto, Voahirana; N'Guessan, Prudence; Argüello, Rafael J; Mussard, Julie; Caux, Christophe; Bendriss-Vermare, Nathalie; Pierre, Philippe; Gatti, Evelina
2017-10-13
Toll-like receptors (TLR) are essential components of the innate immune system. Several accessory proteins, such as UNC93B1, are required for transport and activation of nucleic acid sensing Toll-like receptors in endosomes. Here, we show that BAD-LAMP (LAMP5) controls TLR9 trafficking to LAMP1 + late endosomes in human plasmacytoid dendritic cells (pDC), leading to NF-κB activation and TNF production upon DNA detection. An inducible VAMP3 +/ LAMP2 +/ LAMP1 - endolysosome compartment exists in pDCs from which TLR9 activation triggers type I interferon expression. BAD-LAMP-silencing enhances TLR9 retention in this compartment and consequent downstream signalling events. Conversely, sustained BAD-LAMP expression in pDCs contributes to their lack of type I interferon production after exposure to a TGF-β-positive microenvironment or isolation from human breast tumours. Hence, BAD-LAMP limits interferon expression in pDCs indirectly, by promoting TLR9 sorting to late endosome compartments at steady state and in response to immunomodulatory cues.TLR9 is highly expressed by plasmacytoid dendritic cells and detects nucleic acids, but to discriminate between host and microbial nucleic acids TLR9 is sorted into different endosomal compartments. Here the authors show that BAD-LAMP limits type 1 interferon responses by sorting TLR9 to late endosomal compartments.
Clancy, Eoin; Cormican, Martin; Boo, Teck Wee; Cunney, Robert
2018-01-01
Bacterial meningitis infection is a leading global health concern for which rapid and accurate diagnosis is essential to reduce associated morbidity and mortality. Loop-mediated isothermal amplification (LAMP) offers an effective low-cost diagnostic approach; however, multiplex LAMP is difficult to achieve, limiting its application. We have developed novel real-time multiplex LAMP technology, TEC-LAMP, using Tth endonuclease IV and a unique LAMP primer/probe. This study evaluates the analytical specificity, limit of detection (LOD) and clinical application of an internally controlled multiplex TEC-LAMP assay for detection of leading bacterial meningitis pathogens: Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae. Analytical specificities were established by testing 168 bacterial strains, and LODs were determined using Probit analysis. The TEC-LAMP assay was 100% specific, with LODs for S. pneumoniae, N. meningitidis and H. influenzae of 39.5, 17.3 and 25.9 genome copies per reaction, respectively. Clinical performance was evaluated by testing 65 archived PCR-positive samples. Compared to singleplex real-time PCR, the multiplex TEC-LAMP assay demonstrated diagnostic sensitivity and specificity of 92.3% and 100%, respectively. This is the first report of a single-tube internally controlled multiplex LAMP assay for bacterial meningitis pathogen detection, and the first report of Tth endonuclease IV incorporation into nucleic acid amplification diagnostic technology. PMID:29425124
Higgins, Owen; Clancy, Eoin; Cormican, Martin; Boo, Teck Wee; Cunney, Robert; Smith, Terry J
2018-02-09
Bacterial meningitis infection is a leading global health concern for which rapid and accurate diagnosis is essential to reduce associated morbidity and mortality. Loop-mediated isothermal amplification (LAMP) offers an effective low-cost diagnostic approach; however, multiplex LAMP is difficult to achieve, limiting its application. We have developed novel real-time multiplex LAMP technology, TEC-LAMP, using Tth endonuclease IV and a unique LAMP primer/probe. This study evaluates the analytical specificity, limit of detection (LOD) and clinical application of an internally controlled multiplex TEC-LAMP assay for detection of leading bacterial meningitis pathogens: Streptococcus pneumoniae , Neisseria meningitidis and Haemophilus influenzae . Analytical specificities were established by testing 168 bacterial strains, and LODs were determined using Probit analysis. The TEC-LAMP assay was 100% specific, with LODs for S. pneumoniae , N. meningitidis and H. influenzae of 39.5, 17.3 and 25.9 genome copies per reaction, respectively. Clinical performance was evaluated by testing 65 archived PCR-positive samples. Compared to singleplex real-time PCR, the multiplex TEC-LAMP assay demonstrated diagnostic sensitivity and specificity of 92.3% and 100%, respectively. This is the first report of a single-tube internally controlled multiplex LAMP assay for bacterial meningitis pathogen detection, and the first report of Tth endonuclease IV incorporation into nucleic acid amplification diagnostic technology.
LAMP-2 absence interferes with plasma membrane repair and decreases T. cruzi host cell invasion.
Couto, Natália Fernanda; Pedersane, Dina; Rezende, Luisa; Dias, Patrícia P; Corbani, Tayanne L; Bentini, Lívia C; Oliveira, Anny C S; Kelles, Ludmila F; Castro-Gomes, Thiago; Andrade, Luciana O
2017-06-01
Trypanosoma cruzi enters host cells by subverting the mechanism of cell membrane repair. In this process, the parasite induces small injuries in the host cell membrane leading to calcium entry and lysosomal exocytosis, which are followed by compensatory endocytosis events that drive parasites into host cells. We have previously shown that absence of both LAMP-1 and 2, major components of lysosomal membranes, decreases invasion of T. cruzi into host cells, but the mechanism by which they interfere with parasite invasion has not been described. Here we investigated the role of these proteins in parasitophorous vacuole morphology, host cell lysosomal exocytosis, and membrane repair ability. First, we showed that cells lacking only LAMP-2 present the same invasion phenotype as LAMP1/2-/- cells, indicating that LAMP-2 is an important player during T. cruzi invasion process. Second, neither vacuole morphology nor lysosomal exocytosis was altered in LAMP-2 lacking cells (LAMP2-/- and LAMP1/2-/- cells). We then investigated the ability of LAMP-2 deficient cells to perform compensatory endocytosis upon lysosomal secretion, the mechanism by which cells repair their membrane and T. cruzi ultimately enters cells. We observed that these cells perform less endocytosis upon injury when compared to WT cells. This was a consequence of impaired cholesterol traffic in cells lacking LAMP-2 and its influence in the distribution of caveolin-1 at the cell plasma membrane, which is crucial for plasma membrane repair. The results presented here show the major role of LAMP-2 in caveolin traffic and membrane repair and consequently in T. cruzi invasion.
LAMP-2 absence interferes with plasma membrane repair and decreases T. cruzi host cell invasion
Rezende, Luisa; Bentini, Lívia C.; Oliveira, Anny C. S.
2017-01-01
Trypanosoma cruzi enters host cells by subverting the mechanism of cell membrane repair. In this process, the parasite induces small injuries in the host cell membrane leading to calcium entry and lysosomal exocytosis, which are followed by compensatory endocytosis events that drive parasites into host cells. We have previously shown that absence of both LAMP-1 and 2, major components of lysosomal membranes, decreases invasion of T. cruzi into host cells, but the mechanism by which they interfere with parasite invasion has not been described. Here we investigated the role of these proteins in parasitophorous vacuole morphology, host cell lysosomal exocytosis, and membrane repair ability. First, we showed that cells lacking only LAMP-2 present the same invasion phenotype as LAMP1/2-/- cells, indicating that LAMP-2 is an important player during T. cruzi invasion process. Second, neither vacuole morphology nor lysosomal exocytosis was altered in LAMP-2 lacking cells (LAMP2-/- and LAMP1/2-/- cells). We then investigated the ability of LAMP-2 deficient cells to perform compensatory endocytosis upon lysosomal secretion, the mechanism by which cells repair their membrane and T. cruzi ultimately enters cells. We observed that these cells perform less endocytosis upon injury when compared to WT cells. This was a consequence of impaired cholesterol traffic in cells lacking LAMP-2 and its influence in the distribution of caveolin-1 at the cell plasma membrane, which is crucial for plasma membrane repair. The results presented here show the major role of LAMP-2 in caveolin traffic and membrane repair and consequently in T. cruzi invasion. PMID:28586379
Code of Federal Regulations, 2010 CFR
2010-07-01
... approved by MSHA. (2) MSHA May approve electric lamps and flashlights that incorporate technology for which... PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.1 Purpose. (a) The purpose of the investigations made under this part is to aid in the development and use of electric lamps, other than standard...
Protective clothing for workers with 5-kW and 20-kW short-arc lamps
NASA Technical Reports Server (NTRS)
Argoud, M. J.
1969-01-01
Two suits of protective clothing reduce hazards to personnel working near short-arc lamps. One suit is worn during assembly or servicing of inoperative 5- and 20-kw lamps. The other suit is worn during adjustment or focusing of operating 5-kw lamps.
30 CFR 75.518-2 - Incandescent lamps, overload and short circuit protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Incandescent lamps, overload and short circuit...-General § 75.518-2 Incandescent lamps, overload and short circuit protection. Incandescent lamps installed... or direct current feeder circuits, need not be provided with separate short circuit or overload...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 72.03-15 - Lamp room construction.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Lamp room construction. 72.03-15 Section 72.03-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 72.03-15 Lamp room construction. (a) Lamp, paint, and oil lockers and...
46 CFR 72.03-15 - Lamp room construction.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Lamp room construction. 72.03-15 Section 72.03-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 72.03-15 Lamp room construction. (a) Lamp, paint, and oil lockers and...
46 CFR 72.03-15 - Lamp room construction.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Lamp room construction. 72.03-15 Section 72.03-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 72.03-15 Lamp room construction. (a) Lamp, paint, and oil lockers and...
46 CFR 72.03-15 - Lamp room construction.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Lamp room construction. 72.03-15 Section 72.03-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 72.03-15 Lamp room construction. (a) Lamp, paint, and oil lockers and...
46 CFR 72.03-15 - Lamp room construction.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Lamp room construction. 72.03-15 Section 72.03-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 72.03-15 Lamp room construction. (a) Lamp, paint, and oil lockers and...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
30 CFR 20.6 - General requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.6 General requirements. (a) The lamps shall be durable in construction, practical in operation, and suitable for the service for which... shall be adequate for the use for which the lamp is intended. (c) Battery terminals and leads therefrom...
40 CFR 458.40 - Applicability; description of the carbon black lamp process subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... carbon black lamp process subcategory. 458.40 Section 458.40 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Carbon Black Lamp Process Subcategory § 458.40 Applicability; description of the carbon black lamp process subcategory. The provisions of this subpart are applicable to discharges resulting...
30 CFR 20.6 - General requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.6 General requirements. (a) The lamps shall be durable in construction, practical in operation, and suitable for the service for which... shall be adequate for the use for which the lamp is intended. (c) Battery terminals and leads therefrom...
30 CFR 19.4 - Conditions governing investigations.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.4 Conditions governing investigations. (a) One complete lamp, with the assembly and detail drawings that show the construction of the lamp and... lamp has been inspected by MSHA, the applicant will be notified as to the amount of material that will...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Flashing light units and lamp voltage. 234.253... Maintenance, Inspection, and Testing Inspections and Tests § 234.253 Flashing light units and lamp voltage. (a... proper alignment and frequency of flashes in accordance with installation specifications. (b) Lamp...
46 CFR 92.05-10 - Lamp room construction.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Lamp room construction. 92.05-10 Section 92.05-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 92.05-10 Lamp room construction. (a) Lamp, paint, and...
49 CFR 393.17 - Lamps and reflectors-combinations in driveaway-towaway operation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Lamps and reflectors-combinations in driveaway... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.17 Lamps and reflectors—combinations in driveaway-towaway operation. A combination of...
10 CFR 429.26 - Fluorescent lamp ballasts.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Fluorescent lamp ballasts. 429.26 Section 429.26 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.26 Fluorescent lamp ballasts. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to fluorescent lamp ballasts...
46 CFR 92.05-10 - Lamp room construction.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Lamp room construction. 92.05-10 Section 92.05-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 92.05-10 Lamp room construction. (a) Lamp, paint, and...
46 CFR 92.05-10 - Lamp room construction.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Lamp room construction. 92.05-10 Section 92.05-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 92.05-10 Lamp room construction. (a) Lamp, paint, and...
46 CFR 92.05-10 - Lamp room construction.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Lamp room construction. 92.05-10 Section 92.05-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 92.05-10 Lamp room construction. (a) Lamp, paint, and...