Science.gov

Sample records for electrodes part ii

  1. Conformal growth of anodic nanotubes for dye-sensitized solar cells: part II. Nonplanar electrode.

    PubMed

    Sun, Lidong; Zhang, Sam; Wang, Qing

    2014-02-01

    Anodic titania nanotube array features highly ordered alignment as well as porous nature, and exhibits intriguing properties when employed in a variety of applications. All these profit from the continuous efforts on controlling the nanotube configurations. Recently, nonplanar electrodes have also been used to grow the nanotubes besides the conventional planar counterparts. As such, it is of great interest and significance to complete a picture to link the nanotubes grown on planar and various nonplanar electrodes for a comprehensive understanding of nanotube growing manners, in an attempt to boost their future applications. In the first part of this review, planar electrodes are focused with regard to nanotube growth and application in dye-sensitized solar cells. In this part, the nanotubes grown on patterned or curved surfaces are discussed first with reference to a similar structure of alumina nanopores, which are subsequently used to mirror the growth of nanotubes on cylindrical electrodes (i.e., titanium wires or meshes). The last section focuses on titanium tubular electrodes which are attractive for thermal fluids in view of the drastically reduced thermal conductivity in the presence of anodic nanotubes. As a recent hot topic, wire-shaped dye-sensitized solar cells are deliberated in terms of cell structure, efficiency calculation, merits, challenges and outlook.

  2. Cold starting of fluorescent lamps - part II: experiments on glow times and electrode damaging

    NASA Astrophysics Data System (ADS)

    Langer, Reinhard; Paul, Irina; Hilscher, Achim; Horn, Siegfried; Tidecks, Reinhard

    2017-01-01

    In the present work we present experiments on cold start and the resulting electrode damaging (reducing lamp life) of AC driven fluorescent lamps. The crucial parameter is the glow time, determined from time resolved measurements of lamp voltage and current. The relation between the energy consumed during glow phase and the glow time is studied. It turns out that there is no common threshold of energy until the glow-to-arc transition takes place, but strong energy input into the lamp yields short glow times. The transient behaviour from the glow to the arc regime is investigated and the stable operation points of the arc discharge are determined, yielding an arc discharge voltage-current characteristics of the lamp type investigated. The electrode damage is investigated as a function of the open source voltage and the ballast resistance. Subsequent cold starts lead to an increase of the glow time due to electrode damaging, i.e., the electrode damage accumulates. Different regeneration procedures and their effectiveness are compared. Regeneration burning turns out to be more effective than heating up the electrode. A criterion for avoiding high electrode damage is obtained, indicating that the average power during glow time should exceed 20 W.

  3. Modification of the ultrasound induced activity by the presence of an electrode in a sono-reactor working at two low frequencies (20 and 40 kHz). Part II: Mapping flow velocities by particle image velocimetry (PIV).

    PubMed

    Mandroyan, A; Doche, M L; Hihn, J Y; Viennet, R; Bailly, Y; Simonin, L

    2009-01-01

    Sonoelectrochemical experiments differ from sonochemical ones by the introduction of electrodes in the sonicated reaction vessel. The aim of the study is to characterize the changes in the ultrasonic activity induced by the presence of an electrode located in front of the transducer. The scope of our investigations concerns two low frequency vibration modes: 20 and 40 kHz. For this purpose, two laser visualization techniques have been used. The first part of the study, described in a previous paper (Part I), deals with the laser tomography technique which provides an accurate picture of the reactor active zones, related to numerous cavitation events. The second part of the paper (Part II) will describe the particle image velocimetry (PIV) technique used to measure the velocity vector field in the fluid portion between the horn and the electrode. As for the previous study, two parameters were studied: the electrical power supplied to the transducer and the electrode/transducer distance. The velocity vector fields show a main flow in the reactor axis. This flow seems to correspond to the conical cavitation bubbles structure which is observed on the laser tomography pictures. When an electrode is introduced into the reactor, two additional symmetric transversal flows can be quantified on both sides of the electrode.

  4. Part I. Carbon and mercury-carbon optically transparent electrodes. Part II. Investigation of redox properties of technetium by cyclic voltammetry and thin layer spectroelectrochemistry

    SciTech Connect

    Hurst, R.W.

    1980-01-01

    A carbon optically transparent electrode (C OTE) has been prepared by vapor-deposithing a thin carbon film (150 to 310 A thick) on glass and quartz. Optical transparency is good throughout the ultraviolet-visible region. Electrochemical and spectroelectrochemical measurements were made with ferricyanide and o-tolidine respectively. The C OTE serves as a good substrate for deposition of a thin mercury film to form a mercury film transparent electrode (Hg-C OTE). The Hg-C OTE exhibits electrochemical properties of conventional mercury film electrodes as evidenced by Pb/sup 2 +/ cyclic voltammograms. The Hg-C OTE exhibits electrochemical properties of conventional mercury film electrodes as evidenced by Pb/sup 2 -/ cyclic VOHammograms. The Hg-C OTE enabled the spectrochemical characterization of cysteine oxidation, which was shown to involve the oxidation of mercury to form mercurous cysteinate. An 8080 based microcomputer has been interfaced with a Harrick oscillating mirror rapid scanning uv-visible spectrophotometer. Two different approaches are compared for controlling the galvanometer. The first utilizes the digital hardware on the Harrick processing module to derive the mirror drive waveform, while the second creates the waveform under direct software control. A potentiostat is also interfaced and the system is demonstrated by the spectroelectrochemical determination of the redox potential of o-tolidine. Redox potentials are also determined for a series of technetium complexes by the spectropotentiostatic technique. These include hexahalogens, ditertiary arsine, and 1,2-bis(diphenylphosphino) ethane complexes of technetium. Transient hexavalent technetium is produced, detected, and characterized in aqueous alkaline media by pulse radiolysis and very fast scan cyclic voltammetry. The lifetime is of the order of milliseconds. This species is potentially useful in the preparation of technetium radiopharmaceuticals.

  5. Dissecting Diversity Part II

    ERIC Educational Resources Information Center

    Matthews, Frank

    2005-01-01

    This article presents "Dissecting Diversity, Part II," the conclusion of a wide-ranging two-part roundtable discussion on diversity in higher education. The participants were as follows: Lezli Baskerville, J.D., President and CEO of the National Association for Equal Opportunity (NAFEO); Dr. Gerald E. Gipp, Executive Director of the…

  6. Dissecting Diversity Part II

    ERIC Educational Resources Information Center

    Matthews, Frank

    2005-01-01

    This article presents "Dissecting Diversity, Part II," the conclusion of a wide-ranging two-part roundtable discussion on diversity in higher education. The participants were as follows: Lezli Baskerville, J.D., President and CEO of the National Association for Equal Opportunity (NAFEO); Dr. Gerald E. Gipp, Executive Director of the…

  7. Mycotoxins revisited: Part II.

    PubMed

    Berger, Kyan J; Guss, David A

    2005-02-01

    Mushrooms are ubiquitous in nature. They are an important source of nutrition, however, certain varieties contain chemicals that can be highly toxic to humans. Industrially cultivated mushrooms are historically very safe, whereas foraging for mushrooms or accidental ingestion of mushrooms in the environment can result in serious illness and death. The emergency department is the most common site of presentation for patients suffering from acute mushroom poisoning. Although recognition can be facilitated by identification of a characteristic toxidrome, the presenting manifestations can be variable and have considerable overlap with more common and generally benign clinical syndromes. The goal of this two-part article is to review the knowledge base on this subject and provide information that will assist the clinician in the early consideration, diagnosis and treatment of mushroom poisoning. Part I reviewed the epidemiology and demographics of mushroom poisoning, the physical characteristics of the most toxic varieties, the classification of the toxic species, and presented an overview of the cyclopeptide-containing mushroom class. Part II is focused on the presentation of the other classes of toxic mushrooms along with an up-to-date review of the most recently identified poisonous varieties.

  8. Electrical stimulation and electrode properties. Part 2: pure metal electrodes.

    PubMed

    Stevenson, Matthew; Baylor, Kelly; Netherton, Brett L; Stecker, Mark M

    2010-12-01

    Electrical stimulation can cause significant damage to clinical electrodes as well as patient injury. In this study, the effects of stimulation on pure metal electrodes were investigated without the complexities introduced by the multiple elements that make up the clinical electrode. As with the clinical electrodes, there was significant decomposition of pure stainless steel anodes with no associated significant changes in the cathodes when stimulation employed long pulse durations. Effects of stimulation were greater when the anode and cathode were closer under constant voltage stimulation but were distance independent under constant current stimulation. High ionic content of the solution also increased the degree of damage to the anode as did the presence of chloride in the solution. Electrode composition also influenced the amount damage to the anode. Platinum and platinum-iridium electrodes showed no damage with any stimulus while stainless steel showed the lowest resistance to corrosion for direct current (DC) stimulation. Tungsten electrodes behaved very differently than stainless steel, decomposing with pulse stimulation and resisting decomposition during DC stimulation because of the formation of surface protective layers. Because platinum was able to maintain high levels of current over time, prolonged stimulation produced dramatic increases in the temperature of the solution; however, even short periods of stimulation were sufficient to produce dramatic changes in pH in the neighborhood of the electrode.

  9. Poly(3-methylthiophene)/palladium sub-micro-modified sensor electrode. Part II: Voltammetric and EIS studies, and analysis of catecholamine neurotransmitters, ascorbic acid and acetaminophen.

    PubMed

    Atta, Nada F; El-Kady, Maher F

    2009-08-15

    Promising voltammetric sensors based on the modification of Pt and poly(3-methylthiophene) (PMT) electrodes with Pd nanoparticles were achieved for the determination of catecholamine neurotransmitters, ascorbic acid and acetaminophen. Electrochemistry of the indicated compounds was studied at these electrodes and interesting electrocatalytic effects were found. Furthermore, simple, easily prepared one electrochemical step Pd-modified Pt electrode (Pt/Pd) is reported for the first time. Cyclic voltammetry (CV) and chronocoulometry (CC) were used for the determination of the apparent diffusion coefficients in different electrolytes at these electrodes and the values are in the range from 10(-4) to 10(-5)cm(2)s(-1). Furthermore, it was found that the method of polymer formation had a substantial effect on the synergism between the polymer film and the loaded metal particles towards the oxidation of dopamine (DA) in different supporting electrolytes. This was confirmed by the CV, CC and EIS (electrochemical impedance spectroscopy) as well as SEM (Scanning Electron Microscopy) results. Pt and PMT electrodes modified with Pd nanoparticles showed excellent results for the simultaneous determination of tertiary and quaternary mixtures of the studied compounds.

  10. Rickets: Part II.

    PubMed

    Shore, Richard M; Chesney, Russell W

    2013-01-01

    This is the continuation of a two-part review of rickets. This part emphasizes the specific pathophysiology, clinical features, pathoanatomy and radiographic findings of vitamin D deficiency rickets. Other forms of rickets, differential diagnostic considerations and the potential relationship between low levels of vitamin D metabolites and unexplained fractures in infants are also discussed.

  11. Understanding Math - Part II.

    ERIC Educational Resources Information Center

    Wyks, Hollis W.; Austin, Robert J.

    This is the second remedial workbook-text in a two-part series written for deaf students at the secondary level. It covers fractions, geometry formulas, decimals and percents, and time. For the first workbook, see SE 015 827, and for the teacher's guide, see SE 015 829. (DT)

  12. Rockets -- Part II.

    ERIC Educational Resources Information Center

    Leitner, Alfred

    1982-01-01

    If two rockets are identical except that one engine burns in one-tenth the time of the other (total impulse and initial fuel mass of the two engines being the same), which rocket will rise higher? Why? The answer to this question (part 1 response in v20 n6, p410, Sep 1982) is provided. (Author/JN)

  13. Rockets -- Part II.

    ERIC Educational Resources Information Center

    Leitner, Alfred

    1982-01-01

    If two rockets are identical except that one engine burns in one-tenth the time of the other (total impulse and initial fuel mass of the two engines being the same), which rocket will rise higher? Why? The answer to this question (part 1 response in v20 n6, p410, Sep 1982) is provided. (Author/JN)

  14. Stimulus control: Part II

    PubMed Central

    Dinsmoor, James A.

    1995-01-01

    The second part of my tutorial stresses the systematic importance of two parameters of discrimination training: (a) the magnitude of the physical difference between the positive and the negative stimulus (disparity) and (b) the magnitude of the difference between the positive stimulus, in particular, and the background stimulation (salience). It then examines the role these variables play in such complex phenomena as blocking and overshadowing, progressive discrimination training, and the transfer of control by fading. It concludes by considering concept formation and imitation, which are important forms of application, and recent work on equivalence relations. PMID:22478222

  15. [Part II: Recognising facial expressions].

    PubMed

    Krolak-Salmon, P; Hénaff, M A; Bertrand, O; Vighetto, A; Mauguière, F

    2006-11-01

    In this second part, we address particularly the question of the neural mechanisms and structures involved in the recognition of facial emotional expressions that are crucial in social cognition. Emotion recognition in others can be critically impaired in some neurodegenerative and neurovascular diseases. That dysfunction sometimes correlated to disabling behavioural disorders and interpersonal communication impairment must be further understood. The results of a series of scalp and intracranial event related potential recordings, as well as recent advances in the literature, are reported. ERPs to facial emotional expressions were thus recorded in multiple subcortical and cortical areas in drug refractory epileptical patients implanted with depth electrodes. The roles of amygdala, insula and prefrontal cortex located at crossroads between perceptive analysis and emotional conceptual knowledge are particularly underlined. Altogether, these studies demonstrate that facial expressions are widely processed in space and time, some structures reacting very early and automatically, others providing a sustained reaction depending on the attention.

  16. Fabrication of carbon nanotubes paste electrode for determination of Cd (II) and Pb (II) ions

    NASA Astrophysics Data System (ADS)

    Le Hai, Tran; Hai, Tran Duy

    2017-09-01

    In this study, the electrode for determination of Cd (II) and Pb (II) was prepared by a paste composition of multi-wall carbon nanotubes (MWCNTs) and paraffin oil as a binder. Effect of MWCNTs/paraffin oil ratio on electrochemical behaviors of the electrodes was investigated. For the characterization of the fabricated MWCNT paste electrodes, the cyclic voltammetry, SEM images, RAMAN and XRD spectroscopy were employed. It was found that the electrode containing 20% (w/w) paraffin oil and 80 % (w/w) MWCNTs exhibited the satisfactory properties through the anodic stripping voltammetry (ASV) results. This electrode showed a reversible redox process with an electrochemical mechanism of controlled diffusion. Furthermore, the ASV results of the prepared electrode revealed a linear response of Pb (II) and Cd (II) concentrations with a detection limit of 6.33 µmol.L-1 and 0.42 µmol.L-1, respectively

  17. Copper(I) electrode function of two types of copper(II) ion-selective electrodes.

    PubMed

    Neshkova, M; Sheytanov, H

    1985-08-01

    The response of two types of solid-state copper ion-selective electrodes with homogeneous membranes of CuAgSe and Cu(2-x)Se has been investigated in copper(I) solutions, prepared electrochemically by insitu generation from a copper anode in chloride medium. The selectivity coefficient K(pot)(Cu+, Cu(2+)) both types of electrodes has been determined. It is 10(-5.7) for the copper selenide sensor, and 10(-6.2) for the copper silver selenide one. These values are very close to that calculated for an exchange reaction proceeding on the electrode surface. The similarity in K(pot)(Cu+ ,Cu(2+)) values for different chalcogenidebased sensors suggests a common potential-generating mechanism. High chloride concentration does not interfere with the electrode response towards Cu(I), but distorts the electrode response to Cu(II).

  18. Cultivation of an Obligate Fe(II)-Oxidizing Lithoautotrophic Bacterium Using Electrodes

    PubMed Central

    Summers, Zarath M.; Gralnick, Jeffrey A.; Bond, Daniel R.

    2013-01-01

    ABSTRACT Fe(II)-oxidizing aerobic bacteria are poorly understood, due in part to the difficulties involved in laboratory cultivation. Specific challenges include (i) providing a steady supply of electrons as Fe(II) while (ii) managing rapid formation of insoluble Fe(III) oxide precipitates and (iii) maintaining oxygen concentrations in the micromolar range to minimize abiotic Fe(II) oxidation. Electrochemical approaches offer an opportunity to study bacteria that require problematic electron donors or acceptors in their respiration. In the case of Fe(II)-oxidizing bacteria, if the electron transport machinery is able to oxidize metals at the outer cell surface, electrodes poised at potentials near those of natural substrates could serve as electron donors, eliminating concentration issues, side reactions, and mineral end products associated with metal oxidation. To test this hypothesis, the marine isolate Mariprofundus ferrooxydans PV-1, a neutrophilic obligate Fe(II)-oxidizing autotroph, was cultured using a poised electrode as the sole energy source. When cells grown in Fe(II)-containing medium were transferred into a three-electrode electrochemical cell, a cathodic (negative) current representing electron uptake by bacteria was detected, and it increased over a period of weeks. Cultures scraped from a portion of the electrode and transferred into sterile reactors consumed electrons at a similar rate. After three transfers in the absence of Fe(II), electrode-grown biofilms were studied to determine the relationship between donor redox potential and respiration rate. Electron microscopy revealed that under these conditions, M. ferrooxydans PV-1 attaches to electrodes and does not produce characteristic iron oxide stalks but still appears to exhibit bifurcate cell division. PMID:23362318

  19. Cultivation of an obligate Fe(II)-oxidizing lithoautotrophic bacterium using electrodes.

    PubMed

    Summers, Zarath M; Gralnick, Jeffrey A; Bond, Daniel R

    2013-01-29

    Fe(II)-oxidizing aerobic bacteria are poorly understood, due in part to the difficulties involved in laboratory cultivation. Specific challenges include (i) providing a steady supply of electrons as Fe(II) while (ii) managing rapid formation of insoluble Fe(III) oxide precipitates and (iii) maintaining oxygen concentrations in the micromolar range to minimize abiotic Fe(II) oxidation. Electrochemical approaches offer an opportunity to study bacteria that require problematic electron donors or acceptors in their respiration. In the case of Fe(II)-oxidizing bacteria, if the electron transport machinery is able to oxidize metals at the outer cell surface, electrodes poised at potentials near those of natural substrates could serve as electron donors, eliminating concentration issues, side reactions, and mineral end products associated with metal oxidation. To test this hypothesis, the marine isolate Mariprofundus ferrooxydans PV-1, a neutrophilic obligate Fe(II)-oxidizing autotroph, was cultured using a poised electrode as the sole energy source. When cells grown in Fe(II)-containing medium were transferred into a three-electrode electrochemical cell, a cathodic (negative) current representing electron uptake by bacteria was detected, and it increased over a period of weeks. Cultures scraped from a portion of the electrode and transferred into sterile reactors consumed electrons at a similar rate. After three transfers in the absence of Fe(II), electrode-grown biofilms were studied to determine the relationship between donor redox potential and respiration rate. Electron microscopy revealed that under these conditions, M. ferrooxydans PV-1 attaches to electrodes and does not produce characteristic iron oxide stalks but still appears to exhibit bifurcate cell division. IMPORTANCE Electrochemical cultivation, supporting growth of bacteria with a constant supply of electron donors or acceptors, is a promising tool for studying lithotrophic species in the laboratory

  20. Cobalt(II) selective membrane electrode based on palladium(II) dichloro acetylthiophene fenchone azine.

    PubMed

    Isa, I M; Mustafar, S; Ahmad, M; Hashim, N; Ghani, S A

    2011-12-15

    A new cobalt(II) ion selective electrode based on palladium(II) dichloro acetylthiophene fenchone azine(I) has been developed. The best membrane composition is found to be 10:60:10:21.1 (I)/PVC/NaTPB/DOP (w/w). The electrode exhibits a Nerstian response in the range of 1.0 × 10(-1)-1.0 × 10(-6)M with a detection limit and slope of 8.0 × 10(-7)M and 29.6 ± 0.2 mV per decade respectively. The response time is within the range of 20-25s and can be used for a period of up to 4 months. The electrode developed reveals good selectivity for cobalt(II) and could be used in pH range of 3-7. The electrode has been successfully used in the determination of cobalt(II) in water samples.

  1. Exploring Water Pollution. Part II

    ERIC Educational Resources Information Center

    Rillo, Thomas J.

    1975-01-01

    This is part two of a three part article related to the science activity of exploring environmental problems. Part one dealt with background information for the classroom teacher. Presented here is a suggested lesson plan on water pollution. Objectives, important concepts and instructional procedures are suggested. (EB)

  2. Exploring Water Pollution. Part II

    ERIC Educational Resources Information Center

    Rillo, Thomas J.

    1975-01-01

    This is part two of a three part article related to the science activity of exploring environmental problems. Part one dealt with background information for the classroom teacher. Presented here is a suggested lesson plan on water pollution. Objectives, important concepts and instructional procedures are suggested. (EB)

  3. Expertise revisited, Part II: Contributory expertise.

    PubMed

    Collins, Harry; Evans, Robert; Weinel, Martin

    2016-04-01

    In Part I of this two part paper we tried to elicit the 'essence' of the notion of interactional expertise by looking at its origins. In Part II we will look at the notion of contributory expertise. The exercise has been triggered by recent discussion of these concepts in this journal by Plaisance and Kennedy and by Goddiksen.

  4. Local Area Networks: Part II.

    ERIC Educational Resources Information Center

    Dessy, Raymond E., Ed.

    1982-01-01

    Discusses five approaches used by industry/colleges to provide local area network (LAN) capabilities in the analytical laboratory: (1) mixed baseband bus network coupled to a star net; (2) broadband bus network; (3) ring network; (4) star network coupled to broadband net; and (5) simple multiprocessor center. Part I (September issue) focused on…

  5. Roots/Routes: Part II

    ERIC Educational Resources Information Center

    Swanson, Dalene M.

    2009-01-01

    This narrative acts as an articulation of a journey of many routes. Following Part I of the same research journey of rootedness/routedness, it debates the nature of transformation and transcendence beyond personal and political paradoxes informed by neoliberalism and related repressive globalizing discourses. Through a more personal, descriptive,…

  6. Roots/Routes: Part II

    ERIC Educational Resources Information Center

    Swanson, Dalene M.

    2009-01-01

    This narrative acts as an articulation of a journey of many routes. Following Part I of the same research journey of rootedness/routedness, it debates the nature of transformation and transcendence beyond personal and political paradoxes informed by neoliberalism and related repressive globalizing discourses. Through a more personal, descriptive,…

  7. Playing It Safe: Part II.

    ERIC Educational Resources Information Center

    Penman, Kenneth A.; Niccolai, Frances R.

    1985-01-01

    Explains how to prevent outdoor sports injuries; discusses related litigation and specific cases involving playing field turf, tennis, skiing, and pools; and sets out facility design and maintenance considerations and recommendations. A sidebar provides information about injury insurance available to NCAA schools. Part I of this article appeared…

  8. Understanding Radiation Thermometry. Part II

    NASA Technical Reports Server (NTRS)

    Risch, Timothy K.

    2015-01-01

    This document is a two-part course on the theory and practice of radiation thermometry. Radiation thermometry is the technique for determining the temperature of a surface or a volume by measuring the electromagnetic radiation it emits. This course covers the theory and practice of radiative thermometry and emphasizes the modern application of the field using commercially available electronic detectors and optical components. The course covers the historical development of the field, the fundamental physics of radiative surfaces, along with modern measurement methods and equipment.

  9. Revenue cycle management, Part II.

    PubMed

    Crew, Matt

    2007-01-01

    The proper management of your revenue cycle requires the application of "best practices" and the continual monitoring and measuring of the entire cycle. The correct technology will enable you to gain the insight and efficiencies needed in the ever-changing healthcare economy. The revenue cycle is a process that begins when you negotiate payor contracts, set fees, and schedule appointments and continues until claims are paid in full. Every single step in the cycle carries equal importance. Monitoring all phases and a commitment to continually communicating the results will allow you to achieve unparalleled success. In part I of this article, we explored the importance of contracting, scheduling, and case management as well as coding and clinical documentation. We will now take a closer look at the benefits charge capture, claim submission, payment posting, accounts receivable follow-up, and reporting can mean to your practice.

  10. Sports Concussion Management: part II.

    PubMed

    Terrell, Thomas R; Cox, Conrad B; Bielak, Ken; Casmus, Robert; Laskowitz, Daniel; Nichols, Gregory

    2014-02-01

    Millions of concussions occur every year in the United States. The public interest in concussion has increased after a number of high-profile deaths in high school athletes from sports-related head trauma and in some professional athletes from chronic traumatic encephalopathy. One of the most active areas of research in sports medicine during the last decade has been the evaluation and management of concussion. In this second article of a two-part series, we provide an overview of the latest scientific advances in concussion research. This overview includes an update on the pathobiological changes that occur during concussion and the results of biomechanical studies. In addition, to aid the practicing clinician, we review the literature on proven and currently studied concussion risk factors, including a history of concussion, fatigue, and age. Genetic polymorphisms and biomarkers may provide risk-prediction capability, but at present the research remains inconclusive. Diffusion tensor imaging and functional magnetic resonance imaging are promising technologies that reveal more sophisticated data about the impact of concussion on the brain. We review the existing literature on the application of these neuroimaging modalities to sports concussion. An update from the Fourth International Conference on Concussion in Sport, with highlights of new recommendations, and the presentation of the third edition of the Sports Concussion Assessment Tool to evaluate acute concussion, concludes our review.

  11. Tubing extrusion made easier, Part II.

    PubMed

    Ferrandino, Mike

    2004-11-01

    An increased understanding of the primary elements will lead to greater control of the extrusion process. In the ongoing quest to produce tubing with consistent properties. Part II of this two-part article makes recommendations on best practice in barrel and screw design, compression ratios and dies.

  12. Unlearning Established Organizational Routines--Part II

    ERIC Educational Resources Information Center

    Fiol, C. Marlena; O'Connor, Edward J.

    2017-01-01

    Purpose: The purpose of Part II of this two-part paper is to uncover important differences in the nature of the three unlearning subprocesses, which call for different leadership interventions to motivate people to move through them. Design/methodology/approach: The paper draws on research in behavioral medicine and psychology to demonstrate that…

  13. Epilepsy Care in Developing Countries: Part II of II

    PubMed Central

    Birbeck, Gretchen L

    2010-01-01

    Although 80% of people with epilepsy reside in resource poor, developing countries, epilepsy care in these regions remains limited and the majority of epilepsy patients go untreated. Cost-effective, sustainable epilepsy care services, delivering first-line antiepileptic drugs through established primary health care facilities, are needed to decrease these treatment gaps. Neurologists with local experience and knowledge of the culture, who are willing to serve as educators, policy advisors, and advocates, can make a difference. This is Part II of a two-part article. Part I reviewed the burden of epilepsy and the current state of resources for treatment in developing countries, while Part II will now discuss various aspects of care in these countries. PMID:20944819

  14. Stability of [Ru(II)(tpy)(bpy)(OH(2))](2+)-modified graphite electrodes during indirect electrolyses.

    PubMed

    Geneste, Florence; Moinet, Claude; Ababou-Girard, Soraya; Solal, Francine

    2005-06-13

    The stability of a graphite felt electrode modified by covalent attachment of [Ru(II)(tpy)(bpy)(OH(2))](2+) is investigated during the indirect electrolyses of alcohols in a flow cell. The continuous increase of the local potential of the electrode during the electrolyses attests to its degradation. Cyclic voltammetry analyses of the modified electrode after electrolyses show a total decrease of 80-90% of the wave corresponding to the Ru(III/II) couple. The concentration of remaining alcohol measured at the outlet of the cell is almost constant during all the electrolyses but increase when the potential exceeds 0.95 V(SCE). At low potentials, the electrode can be regenerated by reaction with Ru(II)Cl(2)(DMSO)(tpy) and then CF(3)SO(3)H, followed by hydrolysis, showing that the bipyridine ligand remains covalently attached to the electrode. At high potentials, the graphite is oxidized and the catalyst is partly lost in the reaction medium. XPS analyses of Ru core levels reveal that the ruthenium disappeared after electrolysis, showing that the degradation of the modified electrode is due to the demetalation of the oxidized complex.

  15. Evaluation of commercial lithium-ion cells based on composite positive electrode for plug-in hybrid electric vehicle applications. Part II. Degradation mechanism under 2 C cycle aging

    SciTech Connect

    Matthieu Dubarry; Cyril Truchot; Bor Yann Liaw; Kevin Gering; Sergiy Sazhin; David Jamison; Christopher Michelbacher

    2011-12-01

    Degradation phenomena and inference of their underlying mechanisms during 2 C cycle aging in a cell design comprising {l_brace}LiMn1/3Ni1/3Co1/3O2 + LiMn2O4{r_brace} composite positive electrode are studied and reported in this work. We describe how aging phenomena in the cells were studied and incremental capacity analysis applied to infer cell degradation mechanisms in the cycle aging process. Two stages of degradation were observed in the life cycle under this aging regime. In the first stage, we conclude that loss of lithium inventory was the cause of capacity fade. As a result of such parasitic loss, the cell further suffered from loss of active materials in the second stage, in which the positive electrode kinetics was hampered and the capacity loss accelerated.

  16. The Detection of Motion by Blind Subjects With the Epiretinal 60-Electrode (Argus II) Retinal Prosthesis.

    PubMed

    Dorn, Jessy D; Ahuja, Ashish K; Caspi, Avi; da Cruz, Lyndon; Dagnelie, Gislin; Sahel, Jose-Alain; Greenberg, Robert J; McMahon, Matthew J

    2013-02-01

    To investigate the ability of 28 blind subjects implanted with a 60-electrode Argus II (Second Sight Medical Products Inc) retinal prosthesis system to detect the direction of a moving object. Blind subjects (bare light perception or worse in both eyes) with retinitis pigmentosa were implanted with the Argus II prosthesis as part of a phase 1/2 feasibility study at multiple clinical sites worldwide. The experiment measured their ability to detect the direction of motion of a high-contrast moving bar on a flatscreen monitor in 3 conditions: with the prosthesis system on and a 1-to-1 mapping of spatial information, with the system off, and with the system on but with randomly scrambled spatial information. Fifteen subjects (54%) were able to perform the task significantly better with their prosthesis system than they were with their residual vision, 2 subjects had significantly better performance with their residual vision, and no difference was found for 11 subjects. Of the 15 better-performing subjects, 11 were available for follow-up testing, and 10 of them had significantly better performance with normal rather than with scrambled spatial information. This work demonstrates that blind subjects implanted with the Argus II retinal prosthesis were able to perform a motion detection task they could not do with their native vision, confirming that electrical stimulation of the retina provides spatial information from synchronized activation of multiple electrodes. clinicaltrials.gov Identifier:NCT00407602

  17. The Detection of Motion by Blind Subjects With the Epiretinal 60-Electrode (Argus II) Retinal Prosthesis

    PubMed Central

    Dorn, Jessy D.; Ahuja, Ashish K.; Caspi, Avi; da Cruz, Lyndon; Dagnelie, Gislin; Sahel, Jose-Alain; Greenberg, Robert J.; McMahon, Matthew J.

    2014-01-01

    Objective To investigate the ability of 28 blind subjects implanted with a 60-electrode Argus II (Second Sight Medical Products Inc) retinal prosthesis system to detect the direction of a moving object. Methods Blind subjects (bare light perception or worse in both eyes) with retinitis pigmentosa were implanted with the Argus II prosthesis as part of a phase 1/2 feasibility study at multiple clinical sites worldwide. The experiment measured their ability to detect the direction of motion of a high-contrast moving bar on a flatscreen monitor in 3 conditions: with the prosthesis system on and a 1-to-1 mapping of spatial information, with the system off, and with the system on but with randomly scrambled spatial information. Results Fifteen subjects (54%) were able to perform the task significantly better with their prosthesis system than they were with their residual vision, 2 subjects had significantly better performance with their residual vision, and no difference was found for 11 subjects. Of the 15 better-performing subjects, 11 were available for follow-up testing, and 10 of them had significantly better performance with normal rather than with scrambled spatial information. Conclusions This work demonstrates that blind subjects implanted with the Argus II retinal prosthesis were able to perform a motion detection task they could not do with their native vision, confirming that electrical stimulation of the retina provides spatial information from synchronized activation of multiple electrodes. PMID:23544203

  18. 40 CFR Appendix II to Part 257 - Appendix II to Part 257

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to Part 257 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Pt. 257, App. II Appendix II... from 60 days at 15 °C to 40 days at 20 °C, with a volatile solids reduction of at least 38 percent. Air...

  19. 40 CFR Appendix II to Part 257 - Appendix II to Part 257

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to Part 257 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Pt. 257, App. II Appendix II... from 60 days at 15 °C to 40 days at 20 °C, with a volatile solids reduction of at least 38 percent. Air...

  20. Globalization in the pharmaceutical industry, Part II.

    PubMed

    Casadio Tarabusi, C; Vickery, G

    1998-01-01

    This is the second of a two-part report on the pharmaceutical industry. Part II begins with a discussion of foreign direct investment and inter-firm networks, which covers international mergers, acquisitions, and minority participation; market shares of foreign-controlled firms; international collaboration agreements (with a special note on agreements in biotechnology); and licensing agreements. The final section of the report covers governmental policies on health and safety regulation, price regulation, industry and technology, trade, foreign investment, protection of intellectual property, and competition.

  1. Advanced bionics thin lateral and Helix II electrodes: a temporal bone study.

    PubMed

    Wright, Charles G; Roland, Peter S; Kuzma, Janusz

    2005-11-01

    This study was performed to evaluate the insertional properties of two cochlear implant electrodes recently developed by Advanced Bionics Corporation. Anatomic study using human cadaveric temporal bones. The electrode prototypes we tested are the Thin Lateral and Helix II arrays, which incorporate features designed to minimize insertional trauma. A total of eight electrodes (4 of each prototype) were evaluated after insertion into freshly fixed temporal bones. The electrodes were inserted by way of standard cochleostomies, and the specimens were subsequently dissected to assess electrode position, insertion depth, and intracochlear trauma. Quantitative data regarding insertion depths and contact distances from the modiolus are presented for all electrodes tested. The mean insertion depths were 368 degrees for the Thin Lateral electrodes, which are designed to approximate the lateral cochlear wall, and 436 degrees for the Helix II electrodes, which occupy a more medial position in the scala tympani. No evidence of insertional trauma was observed with either electrode. The ease of insertion and absence of trauma were confirmed during additional trials in which electrode behavior was directly observed during insertion into previously opened cochleas. Both electrodes performed favorably in our human temporal bone trials, and both arrays appear promising for clinical use, especially in patients with residual hearing in whom atraumatic insertion is an important objective.

  2. Optimization of simultaneous electrochemical determination of Cd(II), Pb(II), Cu(II) and Hg(II) at carbon nanotube-modified graphite electrodes.

    PubMed

    Pikna, L'ubomír; Heželová, Mária; Kováčová, Zuzana

    2015-01-01

    The health of the environment is worsening every day. Monitoring of potentially toxic elements and remediation of environmental pollution are necessary. Therefore, the research and development of simple, inexpensive, portable and effective sensors is important. Electrochemistry is a useful component of the field of environment monitoring. The present study focuses on evaluating and comparing three types of electrodes (PIGE, PIGE/MWCNT/HNO3 and PIGE/MWCNT/EDTA/HNO3) employed for the simultaneous electrochemical determination of four potentially toxic elements: Cd(II), Pb(II), Cu(II) and Hg(II). Cyclic voltammograms were measured in an acetate buffer. The LOD, LOQ, the standard and relative precisions of the method and a prediction intervals were calculated (according to the technical procedure DIN 32 645) for the three electrodes and for each measured element. The LOD for PIGE/CNT/HNO3 (the electrode with narrowest calculated prediction intervals) was 2.98 × 10(-7) mol L(-1) for Cd(II), 4.83 × 10(-7) mol L(-1) for Pb(II), 3.81 × 10(-7) mol L(-1) for Cu(II), 6.79 × 10(-7) mol L(-1) for Hg(II). One of the benefits of this study was the determination of the amount of Hg(II) in the mixture of other elements.

  3. Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes.

    PubMed

    Filipe, Olga M S; Brett, Christopher M A

    2003-12-04

    A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 Omega. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO(2) nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO(2) nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated.

  4. Photosensitivity disorders in children: part II.

    PubMed

    Chantorn, Rattanavalai; Lim, Henry W; Shwayder, Tor A

    2012-12-01

    Photosensitivity disorders in children encompass a diverse group of diseases. Some inherited disorders manifest with photosensitivity early in life. Specific extracutaneous association may be the clue to diagnosis in this group of pediatric photodermatoses. Part II of this 2-part review covers hereditary photodermatoses caused by defects in nucleotide excision repair, double strand break repair, or localized or systemic biochemical abnormalities. Diagnosis and management of photoaggravated dermatoses are also discussed. Sun protection strategies are required in all patients with evidence of photosensitivity. Early recognition and prompt diagnosis is essential to minimize the long-term complications associated with inadequate photoprotection. Copyright © 2012 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  5. 10 CFR Appendix II to Part 504 - Fuel Price Computation

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Fuel Price Computation II Appendix II to Part 504 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS Pt. 504, App. II Appendix II to Part 504—Fuel Price Computation (a) Introduction. This appendix provides the equations and...

  6. 10 CFR Appendix II to Part 504 - Fuel Price Computation

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Fuel Price Computation II Appendix II to Part 504 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS Pt. 504, App. II Appendix II to Part... effects of future real price increases for each fuel. The delivered price of an alternate fuel used to...

  7. 10 CFR Appendix II to Part 504 - Fuel Price Computation

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Fuel Price Computation II Appendix II to Part 504 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS Pt. 504, App. II Appendix II to Part... effects of future real price increases for each fuel. The delivered price of an alternate fuel used to...

  8. 10 CFR Appendix II to Part 504 - Fuel Price Computation

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Fuel Price Computation II Appendix II to Part 504 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS Pt. 504, App. II Appendix II to Part... effects of future real price increases for each fuel. The delivered price of an alternate fuel used to...

  9. Mathematical model for silicon electrode - Part I. 2-d model

    NASA Astrophysics Data System (ADS)

    Sikha, Godfrey; De, Sumitava; Gordon, Joseph

    2014-09-01

    This paper presents a 2-dimensional transient numerical model to simulate the electrochemical lithium insertion in a silicon nanowire (Si NW) electrode. The model geometry is a cylindrical Si NW electrode anchored to a copper current collector (Cu CC) substrate. The model solves for diffusion of lithium in Si NW, stress generation in the Si NW due to chemical and elastic strains, stress generation in the Cu CC due to elastic strain, and volume expansion in the Si NW and Cu CC geometries. The evolution of stress components, i.e., radial, axial and tangential stresses in different regions in the Si NW are presented and discussed. The effect of radius of Si NW and lithiation rate, on the maximum stresses developed in the Si NW are also discussed.

  10. Diffuse Cystic Lung Disease. Part II

    PubMed Central

    Vassallo, Robert; Wikenheiser-Brokamp, Kathryn A.; McCormack, Francis X.

    2015-01-01

    The diffuse cystic lung diseases have a broad differential diagnosis. A wide variety of pathophysiological processes spanning the spectrum from airway obstruction to lung remodeling can lead to multifocal cyst development in the lung. Although lymphangioleiomyomatosis and pulmonary Langerhans cell histiocytosis are perhaps more frequently seen in the clinic, disorders such as Birt-Hogg-Dubé syndrome, lymphocytic interstitial pneumonia, follicular bronchiolitis, and light-chain deposition disease are increasingly being recognized. Obtaining an accurate diagnosis can be challenging, and management approaches are highly disease dependent. Unique imaging features, genetic tests, serum studies, and clinical features provide invaluable clues that help clinicians distinguish among the various etiologies, but biopsy is often required for definitive diagnosis. In part II of this review, we present an overview of the diffuse cystic lung diseases caused by lymphoproliferative disorders, genetic mutations, or aberrant lung development and provide an approach to aid in their diagnosis and management. PMID:25906201

  11. Morphology-dependent NiO modified glassy carbon electrode surface for lead(II) and cadmium(II) detection

    NASA Astrophysics Data System (ADS)

    Li, Xuewu; Wen, Hao; Fu, Qiang; Peng, Dai; Yu, Jingui; Zhang, Qiaoxin; Huang, Xingjiu

    2016-02-01

    Glassy carbon electrode (GCE) surfaces have been modified with different NiO morphologies consisting of rods NiO, flakes NiO and balls NiO prepared via the hydrothermal synthesis method for Pb(II) and Cd(II) detection by using the square wave anodic stripping voltammetry (SWASV). Meanwhile, the typical cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), BET surface area and adsorption property of the modified electrode surfaces have been investigated to evaluate their electrochemical detection effect. Results show that balls NiO modified GCE can get the optimal detection ability for its highest detection sensitivity to Pb(II) (13.46 A M-1) and Cd(II) (5.10 A M-1), the lowest detection limit (DL) to Pb(II) (0.08 μM) and Cd(II) (0.07 μM) as well as the superior linear relativity. In addition, an enhanced current at redox peaks, lower electron transfer resistance, larger BET surface area and stronger adsorption capacity have been confirmed for the balls NiO modified GCE surface. Finally, excellent stability and reproducibility of balls NiO modified electrodes for Pb(II) and Cd(II) detection have also been proved via the SWASV responses.

  12. Prediction of periventricular leukomalacia. Part II

    PubMed Central

    Samanta, Biswanath; Bird, Geoffrey L.; Kuijpers, Marijn; Zimmerman, Robert A.; Jarvik, Gail P.; Wernovsky, Gil; Clancy, Robert R.; Licht, Daniel J.; Gaynor, J. William; Nataraj, Chandrasekhar

    2009-01-01

    Summary Objective The objective of Part II is to analyze the dataset of extracted hemodynamic features (Case 3 of Part I) through computational intelligence (CI) techniques for identification of potential prognostic factors for periventricular leukomalacia (PVL) occurrence in neonates with congenital heart disease. Methods The extracted features (Case 3 dataset of Part I) were used as inputs to CI based classifiers, namely, multi-layer perceptron (MLP) and probabilistic neural network (PNN) in combination with genetic algorithms (GA) for selection of the most suitable features predicting the occurrence of PVL. The selected features were next used as inputs to a decision tree (DT) algorithm for generating easily interpretable rules of PVL prediction. Results Prediction performance for two CI based classifiers, MLP and PNN coupled with GA are presented for different number of selected features. The best prediction performances were achieved with 6 and 7 selected features. The prediction success was 100% in training and the best ranges of sensitivity (SN), specificity (SP) and accuracy (AC) in test were 60-73%, 74-84% and 71-74%, respectively. The identified features when used with the DTalgorithm gave best SN, SP and AC in the ranges of 87-90% in training and 80-87%, 74-79% and 79-82% in test. Among the variables selected in CI, systolic and diastolic blood pressures, and pCO2 figured prominently similar to Part I. Decision tree based rules for prediction of PVL occurrence were obtained using the CI selected features. Conclusions The proposed approach combines the generalization capability of CI based feature selection approach and generation of easily interpretable classification rules of the decision tree. The combination of CI techniques with DT gave substantially better test prediction performance than using CI and DT separately. PMID:19162456

  13. Oxygen electrodes for rechargeable alkaline fuel cells-II

    NASA Technical Reports Server (NTRS)

    Swette, L.; Kackley, N.

    1989-01-01

    The primary objective of this program is the investigation and development of electrocatalysts and supports for the positive electrode of moderate temperature single-unit rechargeable alkaline fuel cells. Approximately six support materials and five catalyst materials have been identified to date for further development.

  14. Oxygen electrodes for rechargeable alkaline fuel cells. II

    NASA Technical Reports Server (NTRS)

    Swette, L.; Kackley, N.

    1990-01-01

    The primary objective of this program is the investigation and development of electrocatalysts and supports for the positive electrode of moderate temperature, single-unit, rechargeable alkaline fuel cells. Approximately six support materials and five catalyst materials have been identified to date for further development.

  15. Chemically Modified Electrodes. Part XX. Radiofrequency Plasma Polymerization of Vinylferrocene on Glassy Carbon and Platinum Electrodes.

    DTIC Science & Technology

    1980-01-29

    1978) 3222. 3 N. Oyama and F. C. Anson , J. Amer. Chem. Soc., 101 (1979) 739. 4 Symposium on Chemically Modified Electrodes, Extended Abstracts of...T. Hirotsu, J. Polym. Sci., Polym. Chem. Ed., 16 (1978) 229. 24 N. Oyama, A. P. Brown and F. C. Anson , J. Electroanal. Chem., 87 (1978) 435. 25 H...91232 Dr. Fred Saalfeld Mr. John Boyle Chemistry Division Materials Branch Naval Research Laboratory Naval Ship Engineering Center Washington, D.C

  16. Photoelectrochemical and photocatalytic properties of nanocrystalline TiO II electrodes

    NASA Astrophysics Data System (ADS)

    Oliveira, Haroldo G.; Nery, Daiane C.; Paschoalino, Matheus P.; Jardim, Wilson F.; Longo, Claudia

    2007-09-01

    The electrochemical and photocatalytic properties of a TiO II film deposited on transparent electrodes were investigated. Its electrochemical behavior was typical of an n-type semiconductor electrode. Its photocatalytic activity, investigated for phenol degradation on an optical bench (area of 1 cm2, 5 mL of solution), revealed small currents (3 μA) and poor total organic carbon (TOC) removal (5 %) when the electrode was biased at + 1.1 V in the dark for 3 h. Under polychromatic irradiation, the electrode presented 25 μA of current and 12 % of phenol degradation. A better performance was achieved for photoelectrocatalytic configuration, when the electrode was irradiated and biased with + 0.6 V. Experiments done under irradiation with a metallic vapor lamp using 9 cm2 electrodes and 10 mL of solution revealed that heterogeneous photocatalysis configuration (HPC) resulted in 50 % of TOC removal, while 85 % was achieved by the electro-assisted process (EHPC). Both the configurations exhibited pseudo-first order kinetics for phenol degradation, but the rate constant was two times that of EHPC. The application of a potential bias to the TiO II porous electrode must enhance the photogenerated electron/hole separation, which minimize the charge recombination and increases its photocatalytic activity towards organic pollutant degradation.

  17. 40 CFR Appendix II to Part 261 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false II Appendix II to Part 261 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) IDENTIFICATION AND LISTING OF HAZARDOUS WASTE Appendix II to Part 261 ...

  18. 40 CFR Appendix II to Part 261 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false II Appendix II to Part 261 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) IDENTIFICATION AND LISTING OF HAZARDOUS WASTE Appendix II to Part 261 ...

  19. Voltammetric determination of cysteine using carbon paste electrode modified with Co(II)-Y zeolite.

    PubMed

    Nezamzadeh-Ejhieh, Alireza; Hashemi, Habibeh-Sadat

    2012-01-15

    A novel zeolite modified electrode for use in voltammetric determination of l-cysteine (CySH) was described. The electrode comprises a Co(II)-exchanged zeolite Y as modifier in carbon paste matrix. First, the electrochemical behavior of Co(II) in modified carbon paste electrode was studied. The results demonstrated that diffusion can control the redox process of cobalt cations at the surface of the modified electrode. Then, the behavior of the electrode in the presence of CySH was studied by using cyclic voltammetry and a novel behavior was observed. In high concentration of CySH (above 10 mmol L(-1)), one pair of semi-reversible electrochemical extra peak was observed which was assigned to the processes of oxidation-reduction of CySH at the unmodified and modified electrode. Acidic conditions with respect to the neutral one cause an increase in the electrode response. The modified electrode showed a suitable linear calibration graph in the concentration range of 1.0×10(-9)-1.0×10(-3)mol L(-1) cysteine with a detection limit of 2.37×10(-10)mol L(-1). The influence of potential interfering substances on the peak current was studied and the results showed that the method was highly selective for determination of CySH. Thus, the proposed electrode was used for the determination of CySH in real samples including human blood serum, urine, N-acetylcysteine tablet and powdered poultry feed and the satisfactory results were obtained. Typical features of the sensor can be summarized as: low cost, simple preparation, fast response, good stability and selectivity, wide linear range, low detection limit and high reproducibility.

  20. Electroencephalogram measurement from the hairy part of the scalp using polymer-based dry microneedle electrodes.

    PubMed

    Arai, M; Kudo, Y; Miki, N

    2015-01-01

    This paper reports a successful electroencephalogram (EEG) measurement from the hairy part of the scalp using a polymer-based dry microneedle electrode. The electrode consists of 25 pillars, each of which has a sharp microneedle on the top. Hairs are collected into the gaps of the pillars and the microneedles can reach the scalp surface. Since the microneedles can penetrate through the stratum corneum, no conductive gel is necessary to acquire high quality EEG. We experimentally investigated the pillar diameters in EEG measurement from the occipital region with hairs. The fabricated electrodes successfully measured EEG without any skin preparation or conductive gel.

  1. Covalent immobilization of oriented photosystem II on a nanostructured electrode for solar water oxidation.

    PubMed

    Kato, Masaru; Cardona, Tanai; Rutherford, A William; Reisner, Erwin

    2013-07-24

    Photosystem II (PSII) offers a biological and sustainable route of photochemical water oxidation to O2 and can provide protons and electrons for the generation of solar fuels, such as H2. We present a rational strategy to electrostatically improve the orientation of PSII from a thermophilic cyanobacterium, Thermosynechococcus elongatus , on a nanostructured indium tin oxide (ITO) electrode and to covalently immobilize PSII on the electrode. The ITO electrode was modified with a self-assembled monolayer (SAM) of phosphonic acid ITO linkers with a dangling carboxylate moiety. The negatively charged carboxylate attracts the positive dipole on the electron acceptor side of PSII via Coulomb interactions. Covalent attachment of PSII in its electrostatically improved orientation to the SAM-modified ITO electrode was accomplished via an amide bond to further enhance red-light-driven, direct electron transfer and stability of the PSII hybrid photoelectrode.

  2. 46 CFR Appendix II to Part 153 - Metric Units Used in Part 153

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Part 153—Metric Units Used in Part 153 Parameter Metric (SI unit) Abbreviation Equivalent to English or... 46 Shipping 5 2014-10-01 2014-10-01 false Metric Units Used in Part 153 II Appendix II to Part 153 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS...

  3. 46 CFR Appendix II to Part 153 - Metric Units Used in Part 153

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Part 153—Metric Units Used in Part 153 Parameter Metric (SI unit) Abbreviation Equivalent to English or... 46 Shipping 5 2013-10-01 2013-10-01 false Metric Units Used in Part 153 II Appendix II to Part 153 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS...

  4. 46 CFR Appendix II to Part 153 - Metric Units Used in Part 153

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Part 153—Metric Units Used in Part 153 Parameter Metric (SI unit) Abbreviation Equivalent to English or... 46 Shipping 5 2011-10-01 2011-10-01 false Metric Units Used in Part 153 II Appendix II to Part 153 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS...

  5. 46 CFR Appendix II to Part 153 - Metric Units Used in Part 153

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Part 153—Metric Units Used in Part 153 Parameter Metric (SI unit) Abbreviation Equivalent to English or... 46 Shipping 5 2012-10-01 2012-10-01 false Metric Units Used in Part 153 II Appendix II to Part 153 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS...

  6. Critical appraisal: dental amalgam update--part II: biological effects.

    PubMed

    Wahl, Michael J; Swift, Edward J

    2013-12-01

    Dental amalgam restorations have been controversial for over 150 years. In Part I of this Critical Appraisal, the clinical efficacy of dental amalgam was updated. Here in Part II, the biological effects of dental amalgam are addressed.

  7. 40 CFR Appendix II to Part 86 - Temperature Schedules

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Temperature Schedules II Appendix II... Appendix II to Part 86—Temperature Schedules (a) Ambient temperature cycle for the diurnal emission portion of the evaporative emission test (see § 86.133). Table I—Temperature Versus Time Sequence Use linear...

  8. 40 CFR Appendix II to Part 86 - Temperature Schedules

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Temperature Schedules II Appendix II... Appendix II to Part 86—Temperature Schedules (a) Ambient temperature cycle for the diurnal emission portion of the evaporative emission test (see § 86.133). Table I—Temperature Versus Time Sequence Use linear...

  9. 40 CFR Appendix II to Part 86 - Temperature Schedules

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Temperature Schedules II Appendix II... Appendix II to Part 86—Temperature Schedules (a) Ambient temperature cycle for the diurnal emission portion of the evaporative emission test (see § 86.133). Table I—Temperature Versus Time Sequence Use linear...

  10. 40 CFR Appendix II to Part 86 - Temperature Schedules

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Temperature Schedules II Appendix II... Appendix II to Part 86—Temperature Schedules (a) Ambient temperature cycle for the diurnal emission portion of the evaporative emission test (see § 86.133). Table I—Temperature Versus Time Sequence Use linear...

  11. Talking about the Weather, Part II.

    ERIC Educational Resources Information Center

    Gibb, Allan A.

    1984-01-01

    This second part of a two-part article highlights some mathematics involved in the study of meteorology. Examples are given of the application of mathematics to the study of the atmosphere, with three problems discussed. (MNS)

  12. Talking about the Weather, Part II.

    ERIC Educational Resources Information Center

    Gibb, Allan A.

    1984-01-01

    This second part of a two-part article highlights some mathematics involved in the study of meteorology. Examples are given of the application of mathematics to the study of the atmosphere, with three problems discussed. (MNS)

  13. Water Pollution: Part I, Municipal Wastewaters; Part II, Industrial Wastewaters.

    ERIC Educational Resources Information Center

    Fowler, K. E. M.

    This publication is an annotated bibliography of municipal and industrial wastewater literature. This publication consists of two parts plus appendices. Part one is entitled Municipal Wastewaters and includes publications in such areas as health effects of polluted waters, federal policy and legislation, biology and chemistry of polluted water,…

  14. 40 CFR Appendixes I-Ii to Part 268 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false I Appendixes I-II to Part 268 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) LAND DISPOSAL RESTRICTIONS Appendixes I-II to Part 268...

  15. 40 CFR Appendixes I-Ii to Part 268 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false I Appendixes I-II to Part 268 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) LAND DISPOSAL RESTRICTIONS Appendixes I-II to Part 268...

  16. 40 CFR Appendixes I-Ii to Part 268 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false I Appendixes I-II to Part 268 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) LAND DISPOSAL RESTRICTIONS Appendixes I-II to Part 268...

  17. 40 CFR Appendixes I-Ii to Part 268 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false I Appendixes I-II to Part 268 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) LAND DISPOSAL RESTRICTIONS Appendixes I-II to Part 268...

  18. 40 CFR Appendixes I-Ii to Part 268 - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false I Appendixes I-II to Part 268 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) LAND DISPOSAL RESTRICTIONS Appendixes I-II to Part 268...

  19. Reclaiming Kindergarten: Part II--Questions about Policy

    ERIC Educational Resources Information Center

    Gullo, Dominic F.; Hughes, Kim

    2011-01-01

    Part II of "Reclaiming Kindergarten" continues the discussion related to responding to the crisis in today's kindergarten. In Part II, two policy questions are posed, the answers to which seek to respond to this continuing crisis. The questions center on issues related to engaging families in kindergarten and the need to consider a new early…

  20. Mercury(II) removal from water by electrocoagulation using aluminium and iron electrodes.

    PubMed

    Nanseu-Njiki, Charles Péguy; Tchamango, Serge Raoul; Ngom, Philippe Claude; Darchen, André; Ngameni, Emmanuel

    2009-09-15

    In this work, electrocoagulation was used to evaluate the treatment of synthetic solutions containing mercury(II) of concentration 2 x 10(-5)M. The effects of the distance between the electrodes, current density, charge loading and initial pH on the removal efficiency were investigated, using aluminium and iron electrodes. Analysis of the filtrates resulting from the treatment was made by anodic redissolution in the differential pulse mode. The removal efficiency was above 99.9% when the distance between the electrodes was 3 cm, the current density ranging from 2.5 to 3.125 A dm(-2); for instance, 99.95% of the mercury(II) was eliminated when a charge loading of 9.33 and 15.55 F m(-3) were used for iron and aluminium respectively. In these conditions, by varying the pH of the mercury(II) solutions from 3 to 7, the removal efficiency remained higher than 99%. In addition, some experiments were carried out on a river water contaminated with mercury(II) ions, and the results obtained showed that the presence of organic matter do not influence the efficiency of the treatment. The elimination of mercury(II) ions is best performed with iron, where 15 min of electrolysis was sufficient to reach the highest removal compared to aluminium which required 25 min for the same result.

  1. Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II).

    PubMed

    Moyo, Mambo; Okonkwo, Jonathan O; Agyei, Nana M

    2014-08-01

    The preparation and application of a practical electrochemical sensor for environmental monitoring and assessment of heavy metal ions in samples is a subject of considerable interest. In this paper, a carbon paste electrode modified with maize tassel for the determination of Cu(II) has been proposed. Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) were used to study morphology and identify the functional groups on the modified electrode, respectively. First, Cu(II) was adsorbed on the carbon paste electrode surface at open circuit and voltammetric techniques were used to investigate the electrochemical performances of the sensor. The electrochemical sensor showed an excellent electrocatalytic activity towards Cu(II) at pH 5.0 and by increasing the amount of maize tassel biomass, a maximum response at 1:2.5 (maize tassel:carbon paste; w/w) was obtained. The electrocatalytic redox current of Cu(II) showed a linear response in the range (1.23 μM to 0.4 mM) with the correlation coefficient of 0.9980. The limit of detection and current-concentration sensitivity were calculated to be 0.13 (±0.01) μM and 0.012 (±0.001) μA/μM, respectively. The sensor gave good recovery of Cu(II) in the range from 96.0 to 98.0 % when applied to water samples.

  2. Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode.

    PubMed

    Ashrafi, Amir M; Vytřas, Karel

    2011-10-15

    A new procedure was elaborated to determine mercury(II) using an anodic stripping square-wave voltammetry at the antimony film carbon paste electrode (SbF-CPE). In highly acidic medium of 1M hydrochloric acid, voltammetric measurements can be realized in a wide potential window. Presence of cadmium(II) allows to separate peaks of Hg(II) and Sb(III) and apparently catalyses reoxidation of electrolytically accumulated mercury, thus allowing its determination at ppb levels. Calibration dependence was linear up to 100 ppb Hg with a detection limit of 1.3 ppb. Applicability of the method was tested on the real river water sample.

  3. Disks for the Laboratory Part II.

    ERIC Educational Resources Information Center

    Dessy, Raymond E., Ed.

    1985-01-01

    Part 1 presents the chemistry, physics, and engineering technology associated with magnetic and optical disks. This part explores the subjects of archiving, security, validation and certification, and protection. Questions and issues are raised in each of the areas that both users and vendors should be aware. (JN)

  4. Simultaneous Stripping Detection of Pb(II), Cd(II) and Zn(II) Using a Bimetallic Hg-Bi/Single-Walled Carbon Nanotubes Composite Electrode

    PubMed Central

    Ouyang, Ruizhuo; Zhu, Zhenqian; Tatum, Clarissa E.; Chambers, James Q.; Xue, Zi-Ling

    2011-01-01

    A new, sensitive platform for the simultaneous electrochemical assay of Zn(II), Cd(II) and Pb(II) in aqueous solution has been developed. The platform is based on a new bimetallic Hg-Bi/single-walled carbon nanotubes (SWNTs) composite modified glassy carbon electrode (GCE), demonstrating remarkably improved performance for the anodic stripping assay of Zn(II), Cd(II) and Pb(II). The synergistic effect of Hg and Bi as well as the enlarged, activated surface and good electrical conductivity of SWNTs on GCE contribute to the enhanced activity of the proposed electrode. The analytical curves for Zn(II), Cd(II) an Pb(II) cover two linear ranges varying from 0.5 to 11 μg L-1 and 10 to 130 μg L-1 with correlation coefficients higher than 0.992. The limits of detection for Zn(II), Cd(II) are lower than 2 μg L-1 (S/N = 3). For Pb(II), moreover, there is another lower, linear range from 5 to 1100 ng L-1 with a coefficient of 0.987 and a detection limit of 0.12 ng L-1. By using the standard addition method, Zn(II), Cd(II) and Pb(II) ions in river samples were successfully determined. These results suggest that the proposed method can be applied as a simple, efficient alternative for the simultaneous monitoring of heavy metals in water samples. In addition, this method demonstrates the powerful application of carbon nanotubes in electrochemical analysis of heavy metals. PMID:21660117

  5. Phenomenology of electromagnetic coupling. Part II

    SciTech Connect

    King, R.J.; Ludwigsen, A.P.; Kunz, K.S.

    1985-08-01

    This report is the second of a planned series which summarize efforts at Lawrence Livermore National Laboratory relating to phenomenology studies of back door coupling from several MHz to 10's of GHz. These studies are pertinent to high altitude EMP (HEMP), enhanced HEMP and microwave coupling. Part I dealt with coupling through apertures into large free-standing cavities having, at most, one interior cable. An overview of the effort is given, and a summary of the effects observed in Part I. The main effort since Part I has been devoted to Facilities Development, development of an interior coupling decomposition model and coupling experiments. Projected future effort is discussed.

  6. Evaluation of ADINA. Part II. Operating Characteristics.

    DTIC Science & Technology

    1980-06-08

    Mooney Rivlin material, small/ large deformation i) static ii) dynamic iii) frequency (linear) 3. Spherical shell; elastic, plastic, concrete, small...Neighborhood of Buckling Zone 13 11-8 Typical Negative Stiffness Generated in Neighborhood of Buckling Zone 14 III-1 Rubber Sheet Geometry Material...Properties and Element Model 26 111-2 Global Energy Increment of Rubber Sheet (1st Load Step) 28 111-3 Global Energy Increment of Rubber Sheet (1st Load

  7. Fire prevention on airplanes. Part II

    NASA Technical Reports Server (NTRS)

    Sabatier, J

    1929-01-01

    This part of the report presents a detailed examination of spark prevention, fire extinguishers, and fuel tank location and design. A continued program of investigations and research is also proposed.

  8. Electric injury, Part II: Specific injuries.

    PubMed

    Fish, R M

    2000-01-01

    Electric injury can cause disruption of cardiac rhythm and breathing, burns, fractures, dislocations, rhabdomyolysis, eye and ear injury, oral and gastrointestinal injury, vascular damage, disseminated intravascular coagulation, peripheral and spinal cord injury, and Reflex Sympathetic Dystrophy. Secondary trauma from falls, fires, flying debris, and inhalation injury can complicate the clinical picture. Diagnostic and treatment considerations for electric injuries are described in this article, which is the second part of a three-part series on electric injuries.

  9. Prescription pricing across Canada (Part II).

    PubMed

    Archer, F

    1984-09-01

    The first of a two part article entitled "Prescription Pricing Across Canada" appeared in the June issue of CPJ. The article was prompted by recent press reports of a prescription drug study commissioned by the Saskatchewan government, and the consequent attention-getting headlines. The first article dealt with the Western provinces. The second part discusses prescription pricing in Ontario, Québec, New Brunswick, Nova Scotia, Prince Edward Island, Newfoundland, and the Northwest Territories.

  10. Electrode

    SciTech Connect

    Clere, T.M.

    1983-08-30

    A 3-dimensional electrode is disclosed having substantially coplanar and substantially flat portions and ribbon-like curved portions, said curved portions being symmetrical and alternating in rows above and below said substantially coplanar, substantially flat portions, respectively, and a geometric configuration presenting in one sectional aspect the appearance of a series of ribbon-like oblate spheroids interrupted by said flat portions and in another sectional aspect, 90/sup 0/ from said one aspect, the appearance of a square wave pattern.

  11. Development and characterisation of disposable gold electrodes, and their use for lead(II) analysis.

    PubMed

    Noh, Mohd F Md; Tothill, Ibtisam E

    2006-12-01

    There is an increasing need to assess the harmful effects of heavy-metal-ion pollution on the environment. The ability to detect and measure toxic contaminants on site using simple, cost effective, and field-portable sensors is an important aspect of environmental protection and facilitating rapid decision making. A screen-printed gold sensor in a three-electrode configuration has been developed for analysis of lead(II) by square-wave stripping voltammetry (SWSV). The working electrode was fabricated with gold ink deposited by use of thick-film technology. Conditions affecting the lead stripping response were characterised and optimized. Experimental data indicated that chloride ions are important in lead deposition and subsequent analysis with this type of sensor. A linear concentration range of 10-50 microg L(-1) and 25-300 microg L(-1) with detection limits of 2 microg L(-1) and 5.8 microg L(-1) were obtained for lead(II) for measurement times of four and two minutes, respectively. The electrodes can be reused up to 20 times after cleaning with 0.5 mol L(-1) sulfuric acid. Interference of other metals with the response to lead were also examined to optimize the sensor response for analysis of environmental samples. The analytical utility of the sensor was demonstrated by applying the system to a variety of wastewater and soil sample extracts from polluted sites. The results are sufficient evidence of the feasibility of using these screen-printed gold electrodes for the determination of lead(II) in wastewater and soil extracts. For comparison purposes a mercury-film electrode and ICP-MS were used for validation.

  12. Searching LEXIS and WESTLAW: Part II.

    ERIC Educational Resources Information Center

    Franklin, Carl

    1986-01-01

    This second of a three-part series compares search features (i.e., truncation symbols, boolean operators, proximity operators, phrase searching, save searches) of two databases providing legal information. Search tips concerning charges and effective searching and tables listing functions of commands and proximity operators for both databases are…

  13. The Metis Nation--Part Two II.

    ERIC Educational Resources Information Center

    Dorian, John

    1978-01-01

    This article deals with historical events involving the Metis people from the time Manitoba entered the Confederation to the conclusion of the 1885 battle at Fish Creek near Batoche, Saskatchewan. Part I is in the Summer, 1978 issue of the Northian. (Author/RTS)

  14. Cutting out the Middleman: Part II.

    ERIC Educational Resources Information Center

    Hansen, Shirley; Crittenden, Chris

    1985-01-01

    The second part of the article published in "American School and University," December 1984 (EA 518 236), outlines specific steps administrators need to take to determine whether or not a direct purchase of natural gas is going to benefit their schools. (MLF)

  15. Cutting out the Middleman: Part II.

    ERIC Educational Resources Information Center

    Hansen, Shirley; Crittenden, Chris

    1985-01-01

    The second part of the article published in "American School and University," December 1984 (EA 518 236), outlines specific steps administrators need to take to determine whether or not a direct purchase of natural gas is going to benefit their schools. (MLF)

  16. Inquiry and Living History, Part II

    ERIC Educational Resources Information Center

    Coatney, Sharon; Smalley, Rachel

    2006-01-01

    In the first part of this article, the authors introduced the living history program. This yearly, weeklong program features living portrayals of famous people, which becomes a catalyst for teaching curricular standards, as well as providing the spark for inquiry. Successful implementation of this program requires providing teachers with…

  17. Inquiry and Living History, Part II

    ERIC Educational Resources Information Center

    Coatney, Sharon; Smalley, Rachel

    2006-01-01

    In the first part of this article, the authors introduced the living history program. This yearly, weeklong program features living portrayals of famous people, which becomes a catalyst for teaching curricular standards, as well as providing the spark for inquiry. Successful implementation of this program requires providing teachers with…

  18. Nanocellulosic fiber-modified carbon paste electrode for ultra trace determination of Cd (II) and Pb (II) in aqueous solution.

    PubMed

    Rajawat, Deepak Singh; Kardam, Abhishek; Srivastava, Shalini; Satsangee, Soami Piara

    2013-05-01

    In recent years, increasing awareness of the environmental impact of heavy metals has prompted a demand for monitoring and decontaminating industrial wastes prior to discharging into natural water bodies. This paper describes the preparation and electrochemical application of carbon paste electrode modified with nanocellulosic fibers for the determination of cadmium and lead in water samples using anodic stripping voltammetry. First, cadmium and lead were adsorbed on the carbon paste electrode surface at open circuit potential, followed by anodic stripping voltammetric scan from -1 to 0 V. Different factors affecting sensitivity and precision of the electrode, including accumulating solvent, pH of the accumulating solvent, accumulation time, supporting electrolyte, and scan rate were investigated. The proposed method was also applied to the determination of Cd (II) and Pb (II) in the presence of other interfering metal ions and cetyl trimethyl ammonium bromide, sodium dodecyl sulfate, and Triton X-100 as a representative of cationic, anionic, and neutral surfactants. Linear calibration curves were obtained in the concentration ranges of 150-650 μg L(-1) and 80-300 μg L(-1), respectively, for cadmium and lead at an accumulated time of 10 min with limits of detection 88 and 33 μg L(-1). Optimized working conditions are defined as acetate buffer of pH 5 as accumulating solvent, hydrochloric acid as supporting electrolyte, and scan rate 50 mV/s. This technique does not use mercury and therefore has a positive environmental benefit. The method is reasonably sensitive and selective and has been successfully applied to the determination of trace amounts of Cd (II) and Pb (II) in water samples.

  19. Electrochemical Behavior and Voltammetric Determination of a Manganese(II) Complex at a Carbon Paste Electrode

    PubMed Central

    Karastogianni, Sophia; Girousi, Stella

    2016-01-01

    Investigation of the electrochemical behavior using cyclic voltammetry and detection of [Mn2+(thiophenyl-2-carboxylic acid)2 (triethanolamine)] with adsorptive stripping differential pulse voltammetry. The electrochemical behavior of a manganese(II) complex [Mn2+(thiophenyl-2-carboxylic acid)2(triethanolamine)] (A) was investigated using cyclic and differential pulse voltammetry in an acetate buffer of pH 4.6 at a carbon paste electrode. Further, an oxidation–reduction mechanism was proposed. Meanwhile, an adsorptive stripping differential pulse voltammetric method was developed for the determination of manganese(II) complex. PMID:26819548

  20. Electrochemical Behavior and Voltammetric Determination of a Manganese(II) Complex at a Carbon Paste Electrode.

    PubMed

    Karastogianni, Sophia; Girousi, Stella

    2016-01-01

    Investigation of the electrochemical behavior using cyclic voltammetry and detection of [Mn(2+)(thiophenyl-2-carboxylic acid)2 (triethanolamine)] with adsorptive stripping differential pulse voltammetry. The electrochemical behavior of a manganese(II) complex [Mn(2+)(thiophenyl-2-carboxylic acid)2(triethanolamine)] (A) was investigated using cyclic and differential pulse voltammetry in an acetate buffer of pH 4.6 at a carbon paste electrode. Further, an oxidation-reduction mechanism was proposed. Meanwhile, an adsorptive stripping differential pulse voltammetric method was developed for the determination of manganese(II) complex.

  1. Wound healing: part II. Clinical applications.

    PubMed

    Janis, Jeffrey; Harrison, Bridget

    2014-03-01

    Treatment of all wounds requires adequate wound bed preparation, beginning with irrigation and débridement. Complicated or chronic wounds may also require treatment adjuncts or specialized wound healing products. An extensive body of research and development has introduced novel wound healing therapies and scar management options. In this second of a two-part continuing medical education series on wound healing, the reader is offered an update on current wound healing technologies and recommendations for obtaining optimal outcomes.

  2. Corporate liability: security and violence--Part II.

    PubMed

    Fiesta, J

    1996-04-01

    A hospital can be held liable for injuries resulting from failure to provide adequate, reasonable security Part II of "corporate Liability: Security and Violence" addresses negligent hiring and supervision practices, injury and domestic violence in the workplace and communication procedures.

  3. Managing changes during a clinical investigation, Part II.

    PubMed

    Donawa, Maria

    2003-10-01

    What are the European requirements for managing changes that may occur during a clinical investigation? Part II of this article discusses these requirements and the development of a standard operating procedure to help ensure consistent compliance.

  4. 40 CFR Appendix II to Part 86 - Temperature Schedules

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Temperature Schedules II Appendix II... to Part 86—Temperature Schedules (a) Ambient temperature cycle for the diurnal emission portion of the evaporative emission test (see § 86.133). Table I—Temperature Versus Time Sequence Use linear...

  5. Lead(II)-selective ionophores for ion-selective electrodes: a review.

    PubMed

    Guziński, Marcin; Lisak, Grzegorz; Kupis, Justyna; Jasiński, Artur; Bocheńska, Maria

    2013-08-12

    In potentiometry, high selectivity of the ion-selective membranes must be assured in order to reliably measure various analytes in clinical, industrial and environmental samples. Due to the toxic nature of lead(II) it is important to monitor Pb(2+) distribution in natural waters. This may be achieved by implementation of ion-selective electrodes (ISEs) with high selectivity towards lead(II) and low detection limit. A great number of Pb(2+)-ionophores were synthesized and studied. In this work lead(II)-selective ionophores, starting from late 90s, are gathered and discussed. This work gives a comprehensive description and discussion on the novel and available lead(II)-selective ionophores for ISEs. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Treatment of superficial mycoses: review - part II*

    PubMed Central

    Dias, Maria Fernanda Reis Gavazzoni; Bernardes-Filho, Fred; Quaresma-Santos, Maria Victória Pinto; Amorim, Adriana Gutstein da Fonseca; Schechtman, Regina Casz; Azulay, David Rubem

    2013-01-01

    Superficial fungal infections of the hair, skin and nails are a major cause of morbidity in the world. Choosing the right treatment is not always simple because of the possibility of drug interactions and side effects. The first part of the article discusses the main treatments for superficial mycoses - keratophytoses, dermatophytosis, candidiasis, with a practical approach to the most commonly-used topical and systemic drugs , referring also to their dosage and duration of use. Promising new, antifungal therapeutic alternatives are also highlighted, as well as available options on the Brazilian and world markets. PMID:24474103

  7. Magnet hospitals: Part II. Institutions of excellence.

    PubMed

    Kramer, M; Schmalenberg, C

    1988-02-01

    The oft repeated charge today is to "focus on those who are succeeding!" That's what this report does. Using the eight characteristics identified by Peters and Waterman in their book In Search of Excellence, the study analyzes 16 magnet hospitals to ascertain to what extent they possess characteristics similar to the 'best run' companies in the corporate community. The authors suggest that these magnet hospitals may be dealing effectively with the nursing shortage by creating organizational conditions conducive to eliminating internal nurse shortage. Part I of this article appeared the January 1988 issue of JONA.

  8. Drugs, money and society (Part II).

    PubMed

    Walley, Tom

    2010-09-01

    Pharmacoeconomics started as marketing but has developed into a valuable tool in the fuller assessment of drug therapies. Its principles are now widely accepted, and many countries have government-funded agencies with responsibility for its application, most notably the National Institute for Health and Clinical Excellence in England. Many clinical pharmacologists are active in this area, and the discipline itself is part of the clinical pharmacology trainees' curriculum. Further developments will include value-based pricing and its use in cost sharing arrangements between health service and manufacturers.

  9. Curriculum Redesign in Veterinary Medicine: Part II.

    PubMed

    Macik, Maria L; Chaney, Kristin P; Turner, Jacqueline S; Rogers, Kenita S; Scallan, Elizabeth M; Korich, Jodi A; Fowler, Debra; Keefe, Lisa M

    2017-01-01

    Curricular review is considered a necessary component for growth and enhancement of academic programs and requires time, energy, creativity, and persistence from both faculty and administration. On a larger scale, a comprehensive redesign effort involves forming a dedicated faculty redesign team, developing program learning outcomes, mapping the existing curriculum, and reviewing the curriculum in light of collected stakeholder data. The faculty of the Texas A&M University College of Veterinary Medicine & Biomedical Sciences (TAMU) recently embarked on a comprehensive curriculum redesign effort through partnership with the university's Center for Teaching Excellence. Using a previously developed evidence-based model of program redesign, TAMU created a process for use in veterinary medical education, which is described in detail in the first part of this article series. An additional component of the redesign process that is understated, yet vital for success, is faculty buy-in and support. Without faculty engagement, implementation of data-driven curricular changes stemming from program evaluation may be challenging. This second part of the article series describes the methodology for encouraging faculty engagement through the final steps of the redesign initiative and the lessons learned by TAMU through the redesign process.

  10. Biosimilars in Dermatology: Current Situation (Part II).

    PubMed

    Puig, L; Carretero, G; Daudén, E; Ferrándiz, C; Marrón, S E; Martorell, A; Pérez-Suárez, B; Rodriguez-Cerdeira, C; Ruiz-Villaverde, R; Sánchez-Carazo, J L; Velasco, M

    2015-09-01

    The first biosimilar version of a biologic agent used to treat psoriasis (infliximab) entered the Spanish market on February 16 of this year, and more biosimilars can be expected to follow in the coming months and years. Logically, this new situation will have economic repercussions and alter prescribing patterns among dermatologists. In this second part of the review, we will look at several somewhat contentious issues, such as the extrapolation of indications, interchangeability, and automatic substitution. We will also review the biosimilars with indications for psoriasis currently in the clinical development pipeline and assess their potential to offer comparable efficacy and safety to the reference product while contributing to the sustainability of the public health care system.

  11. The sociogeometry of inequality: Part II

    NASA Astrophysics Data System (ADS)

    Eliazar, Iddo

    2015-05-01

    The study of socioeconomic inequality is of prime economic and social importance, and the key quantitative gauges of socioeconomic inequality are Lorenz curves and inequality indices - the most notable of the latter being the popular Gini index. In this series of papers we present a sociogeometric framework to the study of socioeconomic inequality. In this part we focus on the gap between the rich and the poor, which is quantified by gauges termed disparity curves. We shift from disparity curves to disparity sets, define inequality indices in terms of disparity sets, and introduce and explore a collection of distance-based and width-based inequality indices stemming from the geometry of disparity sets. We conclude with mean-absolute-deviation (MAD) representations of the inequality indices established in this series of papers, and with a comparison of these indices to the popular Gini index.

  12. Submodeling Simulations in Fusion Welds: Part II

    NASA Astrophysics Data System (ADS)

    Bonifaz, E. A.

    2013-11-01

    In part I, three-dimensional transient non-linear sub modeling heat transfer simulations were performed to study the thermal histories and thermal cycles that occur during the welding process at the macro, meso and micro scales. In the present work, the corresponding non-uniform temperature changes were imposed as load conditions on structural calculations to study the evolution of localized plastic strains and residual stresses at these sub-level scales. To reach the goal, a three-dimensional finite element elastic-plastic model (ABAQUS code) was developed. The sub-modeling technique proposed to be used in coupling phase-field (and/or digital microstructures) codes with finite element codes, was used to mesh a local part of the model with a refined mesh based on interpolation of the solution from an initial, relatively coarse, macro global model. The meso-sub-model is the global model for the subsequent micro sub-model. The strategy used to calculate temperatures, strains and residual stresses at the macro, meso and micro scale level, is very flexible to be used to any number of levels. The objective of this research was to initiate the development of microstructural models to identify fusion welding process parameters for preserving the single crystal nature of gas turbine blades during repair procedures. The multi-scale submodeling approach can be used to capture weld pool features at the macro-meso scale level, and micro residual stress and secondary dendrite arm spacing features at the micro scale level.

  13. Overactive bladder - 18 years - Part II.

    PubMed

    Truzzi, Jose Carlos; Gomes, Cristiano Mendes; Bezerra, Carlos A; Plata, Ivan Mauricio; Campos, Jose; Garrido, Gustavo Luis; Almeida, Fernando G; Averbeck, Marcio Augusto; Fornari, Alexandre; Salazar, Anibal; Dell'Oro, Arturo; Cintra, Caio; Sacomani, Carlos Alberto Ricetto; Tapia, Juan Pablo; Brambila, Eduardo; Longo, Emilio Miguel; Rocha, Flavio Trigo; Coutinho, Francisco; Favre, Gabriel; Garcia, Jose Antonio; Castano, Juan; Reyes, Miguel; Leyton, Rodrigo Eugenio; Ferreira, Ruiter Silva; Duran, Sergio; Lopez, Vanda; Reges, Ricardo

    2016-01-01

    Traditionally, the treatment of overactive bladder syndrome has been based on the use of oral medications with the purpose of reestablishing the detrusor stability. The recent better understanding of the urothelial physiology fostered conceptual changes, and the oral anticholinergics - pillars of the overactive bladder pharmacotherapy - started to be not only recognized for their properties of inhibiting the detrusor contractile activity, but also their action on the bladder afference, and therefore, on the reduction of the symptoms that constitute the syndrome. Beta-adrenergic agonists, which were recently added to the list of drugs for the treatment of overactive bladder, still wait for a definitive positioning - as either a second-line therapy or an adjuvant to oral anticholinergics. Conservative treatment failure, whether due to unsatisfactory results or the presence of adverse side effects, define it as refractory overactive bladder. In this context, the intravesical injection of botulinum toxin type A emerged as an effective option for the existing gap between the primary measures and more complex procedures such as bladder augmentation. Sacral neuromodulation, described three decades ago, had its indication reinforced in this overactive bladder era. Likewise, the electric stimulation of the tibial nerve is now a minimally invasive alternative to treat those with refractory overactive bladder. The results of the systematic literature review on the oral pharmacological treatment and the treatment of refractory overactive bladder gave rise to this second part of the review article Overactive Bladder - 18 years, prepared during the 1st Latin-American Consultation on Overactive Bladder.

  14. Adhesive-composite incompatibility, part II.

    PubMed

    Carvalho, Ricardo M; Garcia, Fernanda Cristina P; e Silva, Safira M A; Castro, Fabrício L A

    2005-01-01

    Apart from some questions related to the repairability of resin composite restorations, dentists have always assumed that methacrylate-based resins are compatible with each other. For example, there is no clinically relevant problem in using a microfilled composite to laminate a Class IV restoration made with a hybrid composite, even if they are not of the same brand or manufacturer. In the context of adhesive systems, we have always believed that resin composites, regardless of their type or composition, bond well to all types of bonding agents. However, unexpected debonding of self-cured, core buildup composites that had been bonded with single-bottle adhesive systems was reported about 5 years ago. Subsequent studies demonstrated that there were, indeed, compatibility problems between simplified adhesive systems and self- or dual-cured resin composites. Apparently, when such combinations are used, reduced bond strengths and subsequent failures at the resin-adhesive interface can occur because of adverse reactions between the acidic resin monomers, an integral part of the simplified adhesive systems, and the chemicals involved in the polymerization mechanism of the self- or dual-cured composites, particularly the basic tertiary amines.

  15. DICOM: key concepts--part II.

    PubMed

    Kabachinski, Jeff

    2005-01-01

    The objective of these two installments of IT World was to give a general overview of DICOM and to take a look at different parts of the standard to get a sense of its main themes. We found that the standard provides a common reference for all developers but does not impose a single type of implementation. This allows for innovation. The standard is also built for flexibility, able to adapt to new modalities that have a need to communicate. The speedy acceptance of DICOM by the medical imaging industry is opening new possibilities for healthcare organizations to increase the quality while decreasing the cost of patient care. All of the DICOM networked supporting medical equipment as well as the organization's computer systems made by multiple original equipment manufacturers and located at one site or many sites can communicate by means of DICOM. This gives us the opportunity for medical images to be captured and communicated quicker. The result enables physicians to make diagnoses and treatment decisions sooner. It's all good stuff and even more reason why we should endeavor to understand the basics of DICOM. DICOM is here to stay!

  16. A Physicist for All Seasons: Part II

    NASA Astrophysics Data System (ADS)

    Oppenheimer, Frank

    2013-06-01

    The second part of this interview covers Frank Oppenheimer's move to the University of California at Berkeley and wartime work at the Westinghouse Research Laboratories in Pittsburgh, Pennsylvania, at the electromagnetic-separation plant in Oak Ridge, Tennessee, and at Los Alamos, New Mexico (1941-1945); his postwar research at Berkeley (1945-1947); his appointment at the University of Minnesota in 1947 and firing two years later after being required to testify before the House Un-American Activities Committee; his decade as a rancher in Colorado (1949-1959) and high-school science teacher toward the end of this period; his research at the University of Colorado in Boulder after 1959; his year as a Guggenheim Fellow at University College London in 1965; and his founding of the Exploratorium in San Francisco. California, in 1969. He also discusses his wartime relations with his older brother Robert and postwar events in Robert's life, including his Hearings before the Personnel Security Board of the Atomic Energy Commission in 1954.

  17. Generic drugs in dermatology: part II.

    PubMed

    Payette, Michael; Grant-Kels, Jane M

    2012-03-01

    In part I, we discussed new drug development, reviewed the history of the generic drug industry, described how generic drugs are approved by the US Food and Drug Administration, and defined the concepts of bioequivalence and therapeutic equivalence. Herein, we explore various factors impacting generic drug use across the different parties involved: the prescriber, the pharmacist, the patient, and the payer. We also include original cost analysis of dermatologic brand name and generic drugs and show the potential cost savings that can be achieved through generic substitution. We conclude with a review of the data addressing potential differences in the effectiveness of brand name versus generic drugs in dermatology. The cost of brand name and generic medications is highly variable by pharmacy, state, and payer. We used one source (www.drugstore.com) as an example and for consistency across all medications discussed herein. Prices included here may not reflect actual retail prices across the United States. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Wave Propagation in Polymers, Part II

    NASA Astrophysics Data System (ADS)

    Newlander, David C.; Charest, Jacques A.; Lilly, Martin D.; Eisler, Robert D.

    1999-06-01

    Work reported in a previous study (Wave Propagations in Polymers, Part I, J.A. Charest, M.D. Lilly, 44th ARA Meeting Munich, Germany Sept. 17-20, 1993) discussed gas gun plane wave impact work and the measurements of stress wave profiles in Polycarbonate at around 2 kbars. The wave profiles were obtained using combined carbon and PVDF thin film stress gauges. The results showed amplitude attenuation and dispersion effects which were neither expected nor predictable from available hydrocode models. The data have been revisited using a modified material model and the PUFF74 computer code. These new wave profile calculations show remarkable agreement with the previous experiments in Polycarbonate. The model treats the material as viscoelastic-plastic using methods developed by Bade (Dynamic Response Model for PMMA, W. L. Bade, AVCO Systems Division, TR K500-74-WLB-204, Oct. 1, 1974). The measured and calculated results are quite different from those exhibited by PMMA at similar impact conditions. This work is expected to further our understanding of the processes that control wave propagation in highly-compressible and viscoelastic/viscoplastic media. It is also expected to provide clues on the effects of high strain rates on properties such as the modulus of elasticity, strength, and material loading behavior.

  19. [Conceptual Development in Cognitive Science. Part II].

    PubMed

    Fierro, Marco

    2012-03-01

    Cognitive science has become the most influential paradigm on mental health in the late 20(th) and the early 21(st) centuries. In few years, the concepts, problem approaches and solutions proper to this science have significantly changed. Introduction and discussion of the fundamental concepts of cognitive science divided in four stages: Start, Classic Cognitivism, Connectionism, and Embodying / Enacting. The 2(nd) Part of the paper discusses the above mentioned fourth stage and explores the clinical setting, especially in terms of cognitive psychotherapy. The embodying/enacting stage highlights the role of the body including a set of determined evolutionary movements which provide a way of thinking and exploring the world. The performance of cognitive tasks is considered as a process that uses environmental resources that enhances mental skills and deploys them beyond the domestic sphere of the brain. On the other hand, body and mind are embedded in the world, thus giving rise to cognition when interacting, a process known as enacting. There is a close connection between perception and action, hence the interest in real-time interactions with the world rather than abstract reasoning. Regarding clinics, specifically the cognitive therapy, there is little conceptual discussion maybe due to good results from practice that may led us to consider that theoretical foundations are firm and not problem-raising. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  20. Electrochemical study of NO conversion from Fe(II)-EDTA-NO complex on Pt electrodes

    SciTech Connect

    Juzeliunas, E.; Juettner, K.

    1998-01-01

    The Fe(II)-ethylenediaminetetraacetic acid (EDTA)-NO complex formed by interaction of gaseous nitrous oxide (ca. 200 ppm) and Fe(II)-EDTA in aqueous solution was found to be convert3ed electrochemically on platinum electrodes at potentials below ca. {minus}0.6 V{sub SCE}, indicating the cathodic reduction of NO. In addition to the previous studies by which the indirect conversion of NO with dithionite as a redox mediator was confirmed, the present results should elucidate the possibility of the direct electrochemical conversion of NO in mediator-free solutions. To clearly separate this process from other reactions in the system, the electrochemical behavior of Fe(II)-EDTA and Fe(III)-EDTA was studied over a wide potential range at different pH values. Five electrode reactions could be identified, which include the oxidation/reduction of Fe{sup 2+}/Fe{sup 3+} in the EDTA complex, the reduction of EDTA, the reduction of protons, the cathodic deposition of iron, and the anodic decomposition of EDTA. The electrochemical deposition of iron from Fe(II)-EDTA at potentials E < {minus}1.0 V{sub SCE} was confirmed by electrochemical quartz crystal microbalance measurements and energy-dispersive x-ray analysis.

  1. Correctional Training. Institution Familiarization. Part II: The Training Program.

    ERIC Educational Resources Information Center

    Bureau of Prisons (Dept. of Justice), Washington, DC.

    Designed to assist training coordinators in the initial institution familiarization training for new employees in correctional institutions, this manual consists of two documents: a training coordinator's guide (Part I - CE 017 285) and this document, the training program (Part II). Four training areas are treated: (1) an introduction consisting…

  2. Calculus of Elementary Functions, Part II. Teacher's Commentary. Revised Edition.

    ERIC Educational Resources Information Center

    Herriot, Sarah T.; And Others

    This course is intended for students who have a thorough knowledge of college preparatory mathematics, including algebra, axiomatic geometry, trigonometry, and analytic geometry. This teacher's guide is for Part II of the course. It is designed to follow Part I of the text. The guide contains background information, suggested instructional…

  3. Kick, Glide, Pole! Cross-Country Skiing Fun (Part II)

    ERIC Educational Resources Information Center

    Duoos, Bridget A.

    2012-01-01

    Part I of Kick, Glide, Pole! Cross-Country Skiing Fun, which was published in last issue, discussed how to select cross-country ski equipment, dress for the activity and the biomechanics of the diagonal stride. Part II focuses on teaching the diagonal stride technique and begins with a progression of indoor activities. Incorporating this fun,…

  4. Kick, Glide, Pole! Cross-Country Skiing Fun (Part II)

    ERIC Educational Resources Information Center

    Duoos, Bridget A.

    2012-01-01

    Part I of Kick, Glide, Pole! Cross-Country Skiing Fun, which was published in last issue, discussed how to select cross-country ski equipment, dress for the activity and the biomechanics of the diagonal stride. Part II focuses on teaching the diagonal stride technique and begins with a progression of indoor activities. Incorporating this fun,…

  5. Photoprotection: part II. Sunscreen: development, efficacy, and controversies.

    PubMed

    Jansen, Rebecca; Osterwalder, Uli; Wang, Steven Q; Burnett, Mark; Lim, Henry W

    2013-12-01

    In addition to the naturally occurring, physical, and systemic photoprotective agents reviewed in part I, topical ultraviolet radiation filters are an important cornerstone of photoprotection. Sunscreen development, efficacy, testing, and controversies are reviewed in part II of this continuing medical education article. Copyright © 2013 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  6. Corporate Library Impact, Part II: Methodological Trade-Offs

    ERIC Educational Resources Information Center

    Edgar, William

    2004-01-01

    This article and its accompanying one address the corporate library's contribution to its parent firm. Part I reviews the literature on determining this contribution, revealing the need for a more theoretical approach to this problem. It then presents this approach. This article, Part II, reviews methodological trade-offs in pursuing this new…

  7. Crown ether-modified electrodes for the simultaneous stripping voltammetric determination of Cd(II), Pb(II) and Cu(II).

    PubMed

    Serrano, Núria; González-Calabuig, Andreu; del Valle, Manel

    2015-06-01

    This work describes the immobilization of 4-carboxybenzo-18-crown-6 (CB-18-crown-6) and 4-carboxybenzo-15-crown-5 (CB-15-crown-5) assisted by lysine on aryl diazonium salt monolayers anchored to the surface of graphite-epoxy composite electrodes (GEC), and their use for the simultaneous determination of Cd(II), Pb(II) and Cu(II) by differential pulse anodic stripping voltammetry (DPASV). These modified electrodes display a good repeatability and reproducibility with detection and quantification limits at levels of µg L(-1) (ppb), confirming their suitability for the determination of Cd(II), Pb(II) and Cu(II) ions in environmental samples. The overlapped nature of the multimetal stripping measurements was resolved by employing the two-sensor array CB-15-crown-5-GEC and CB-18-crown-6-GEC, since the metal complex selectivity exhibited by the considered ligands could add some discrimination power. For the processing of the voltammograms, Discrete Wavelet Transform and Causal Index were selected as preprocessing tools for data compression coupled with an artificial neural network for the modeling of the obtained responses, allowing the resolution of mixtures of these metals with good prediction of their concentrations (correlation with expected values for an external test subset better than 0.942).

  8. Minimizing Glovebox Glove Breaches: PART II.

    SciTech Connect

    Cournoyer, M. E.; Andrade, R.M.; Taylor, D. J.; Stimmel, J. J.; Zaelke, R. L.; Balkey, J. J.

    2005-01-01

    As a matter of good business practices, a team of glovebox experts from Los Alamos National Laboratory (LANL) has been assembled to proactively investigate processes and procedures that minimize unplanned breaches in the glovebox, e.g., glove failures. A major part of this effort involves the review of glovebox glove failures that have occurred at the Plutonium Facility and at the Chemical and Metallurgy Research Facility. Information dating back to 1993 has been compiled from formal records. This data has been combined with information obtained from a baseline inventory of about 9,000 glovebox gloves. The key attributes tracked include those related to location, the glovebox glove, type and location of breaches, the worker, and the consequences resulting from breaches. This glovebox glove failure analysis yielded results in the areas of the ease of collecting this type of data, the causes of most glove failures that have occurred, the effectiveness of current controls, and recommendations to improve hazard control systems. As expected, a significant number of breaches involve high-risk operations such as grinding, hammering, using sharps (especially screwdrivers), and assembling equipment. Surprisingly, tasks such as the movement of equipment and material between gloveboxes and the opening of cans are also major contributions of breaches. Almost half the gloves fail within a year of their install date. The greatest consequence for over 90% of glovebox glove failures is alpha contamination of protective clothing. Personnel self-monitoring at the gloveboxes continues to be the most effective way of detecting glovebox glove failures. Glove failures from these tasks can be reduced through changes in procedures and the design of remote-handling apparatus. The Nuclear Materials Technology Division management uses this information to improve hazard control systems to reduce the number of unplanned breaches in the glovebox further. As a result, excursions of contaminants

  9. EDUCATION AND THE DEVELOPMENT OF IN-RESIDENCE TRAINING PROGRAMS, PART I, PART II.

    ERIC Educational Resources Information Center

    MELICAN, ROBERT L.; PURCELL, FRANCIS P.

    THE TWO PARTS OF THIS DISCUSSION CONSIDER THE DEVELOPMENT OF RESIDENTIAL PROGRAMS FOR VOCATIONAL AND SOCIAL TRAINING TO MEET THE PROBLEMS OF THE LOW-INCOME SCHOOL DROPOUT. PART I REVIEWS THE HISTORICAL BACKGROUND OF RESIDENCY PROGRAMS IN SUCH EDUCATIONAL INSTITUTIONS AS COLLEGES, UNIVERSITIES, CHURCHES, AND SUMMER CAMPS. PART II DEALS WITH THE…

  10. Ontario Universities Benefits Survey, 1991-92. Part I: Benefits Excluding Pensions [and] Part II: Pensions.

    ERIC Educational Resources Information Center

    Council of Senior Administrative Officers--Universities of Ontario, Toronto.

    This report, which combined Part I and Part II of a benefit study, presents data from a survey of Ontario universities concerning fringe benefits offered in 1991-92. Part I is made up of a series of tables displaying the information on particular benefits institution-by-institution. The first five tables cover general aspects of benefits,…

  11. The renewable bismuth bulk annular band working electrode: fabrication and application in the adsorptive stripping voltammetric determination of nickel(II) and cobalt(II).

    PubMed

    Baś, Bogusław; Węgiel, Krystian; Jedlińska, Katarzyna

    2015-06-30

    The paper presents the first report on fabrication and application of a user friendly and mercury free electrochemical sensor, with the renewable bismuth bulk annular band working electrode (RBiABE), in stripping voltammetry (SV). The sensor body is partly filled with the internal electrolyte solution, in which the RBiABE is cleaned and activated before each measurement. Time of the RBiABE contact with the sample solution is precisely controlled. The usefulness of this sensor was tested by Ni(II) and Co(II) traces determination by means of differential pulse adsorptive stripping voltammetry (DP AdSV), after complexation with dimethylglyoxime (DMG) in ammonia buffer (pH 8.2). The experimental variables (composition of the supporting electrolyte, pre-concentration potential and time, potential of the RBiABE activation, and DP parameters), as well as possible interferences, were investigated. The linear calibration graphs for Ni(II) and Co(II), determined individually and together, in the range from 1×10(-8) to 70×10(-8)molL(-1) and from 1×10(-9) to 70×10(-9)molL(-1) respectively, were obtained. The calculated limit of detection (LOD), for 30s of the accumulation time, was 3×10(-9)molL(-1) for Ni(II) in case of a single element's analysis, whereas the LOD was 5×10(-9)molL(-1) for Ni(II) and 3×10(-10)molL(-1) for Co(II), when both metal ions were measured together. The repeatability of the Ni(II) and Co(II) adsorptive stripping voltammetric signals obtained at the RBiABE were equal to 5.4% and 2.5%, respectively (n=5). Finally, the proposed method was validated by determining Ni(II) and Co(II) in the certified reference waters (SPS-SW1 and SPS-SW2) with satisfactory results.

  12. A Disposable Microfluidic Device with a Screen Printed Electrode for Mimicking Phase II Metabolism

    PubMed Central

    Vasiliadou, Rafaela; Nasr Esfahani, Mohammad Mehdi; Brown, Nathan J.; Welham, Kevin J.

    2016-01-01

    Human metabolism is investigated using several in vitro methods. However, the current methodologies are often expensive, tedious and complicated. Over the last decade, the combination of electrochemistry (EC) with mass spectrometry (MS) has a simpler and a cheaper alternative to mimic the human metabolism. This paper describes the development of a disposable microfluidic device with a screen-printed electrode (SPE) for monitoring phase II GSH reactions. The proposed chip has the potential to be used as a primary screening tool, thus complementing the current in vitro methods. PMID:27598162

  13. Electroanalytical determination of cadmium(II) and lead(II) using an in-situ bismuth film modified edge plane pyrolytic graphite electrode.

    PubMed

    Kachoosangi, Roohollah Torabi; Banks, Craig E; Ji, Xiaobo; Compton, Richard G

    2007-03-01

    A highly sensitive and simple electroanalytical methodology is presented using an in-situ bismuth film modified edge plane pyrolytic graphite electrode (BiF-EPPGE) which is exemplified with the simultaneous determination of cadmium(II) and lead(II). Square-wave anodic stripping voltammetry is utilised with the effects of several experimental variables studied. Simultaneous additions of cadmium(II) and lead(II) were investigated where two linear ranges between 0.1-100 and 0.1-300 microg/L and also detection limits of 0.062 and 0.084 microg/L were obtained, respectively. The method was then successfully applied to the simultaneous determination of cadmium(II) and lead(II) in spiked river water, where recoveries of 100.5 and 98% were obtained, respectively. This electroanalytical protocol using edge plane pyrolytic graphite electrodes is one of the simplest methodologies to date using non-mercury based electrodes and is simpler and cheaper than alternatives such as carbon nanotube electrode arrays, suggesting the use of edge plane pyrolytic graphite electrode for routine sensing.

  14. AT2 DS II - Accelerator System Design (Part II) - CCC Video Conference

    SciTech Connect

    2010-12-17

    Discussion Session - Accelerator System Design (Part II) Tutors: C. Darve, J. Weisend II, Ph. Lebrun, A. Dabrowski, U. Raich Video Conference with the CERN Control Center. Experts in the field of Accelerator science will be available to answer the students questions. This session will link the CCC and SA (using Codec VC).

  15. AT2 DS II - Accelerator System Design (Part II) - CCC Video Conference

    ScienceCinema

    None

    2016-07-12

    Discussion Session - Accelerator System Design (Part II) Tutors: C. Darve, J. Weisend II, Ph. Lebrun, A. Dabrowski, U. Raich Video Conference with the CERN Control Center. Experts in the field of Accelerator science will be available to answer the students questions. This session will link the CCC and SA (using Codec VC).

  16. Recent Economic Perspectives on Political Economy, Part II*

    PubMed Central

    Dewan, Torun; Shepsle, Kenneth A.

    2013-01-01

    In recent years some of the best theoretical work on the political economy of political institutions and processes has begun surfacing outside the political science mainstream in high quality economics journals. This two-part paper surveys these contributions from a recent five-year period. In Part I, the focus is on elections, voting and information aggregation, followed by treatments of parties, candidates, and coalitions. In Part II, papers on economic performance and redistribution, constitutional design, and incentives, institutions, and the quality of political elites are discussed. Part II concludes with a discussion of the methodological bases common to economics and political science, the way economists have used political science research, and some new themes and arbitrage opportunities. PMID:23606754

  17. Recent Economic Perspectives on Political Economy, Part II.

    PubMed

    Dewan, Torun; Shepsle, Kenneth A

    2008-07-01

    In recent years some of the best theoretical work on the political economy of political institutions and processes has begun surfacing outside the political science mainstream in high quality economics journals. This two-part paper surveys these contributions from a recent five-year period. In Part I, the focus is on elections, voting and information aggregation, followed by treatments of parties, candidates, and coalitions. In Part II, papers on economic performance and redistribution, constitutional design, and incentives, institutions, and the quality of political elites are discussed. Part II concludes with a discussion of the methodological bases common to economics and political science, the way economists have used political science research, and some new themes and arbitrage opportunities.

  18. Electrochemical determination of cadmium(II) at platinum electrode modified with kaolin by square wave voltammetry.

    PubMed

    Mhammedi, M A El; Achak, M; Hbid, M; Bakasse, M; Hbid, T; Chtaini, A

    2009-10-30

    In this work, determination of cadmium(II) using square wave voltammetry (SWV) was described. The method is based on accumulation of these metal ions on kaolin platinum electrode (K/Pt). The K/Pt performance was optimized with respect to the surface modification and operating conditions. The optimized conditions were obtained in pH of 5.0 and accumulation time of 25 min. Under the optimal conditions, the relationship between the peak current versus concentration was linear over the range of 9 x 10(-8) to 8.3 x 10(-6) mol L(-1). The detection limit (DL, 3sigma) was 5.4 x 10(-9) mol L(-1). The analytical methodology was successfully applied to monitor the Cd(II) content in natural water. Interferences were also evaluated.

  19. Nursing Care of Patients Undergoing Chemotherapy Desensitization: Part II.

    PubMed

    Jakel, Patricia; Carsten, Cynthia; Carino, Arvie; Braskett, Melinda

    2016-04-01

    Chemotherapy desensitization protocols are safe, but labor-intensive, processes that allow patients with cancer to receive medications even if they initially experienced severe hypersensitivity reactions. Part I of this column discussed the pathophysiology of hypersensitivity reactions and described the development of desensitization protocols in oncology settings. Part II incorporates the experiences of an academic medical center and provides a practical guide for the nursing care of patients undergoing chemotherapy desensitization.
.

  20. High Performance Liquid Chromatography/Video Fluorometry. Part II. Applications.

    DTIC Science & Technology

    1981-09-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY /VIDEO FLUOROMETRY. PART...REP«T_N&:-ŗ/ High Performance Liquid Chromatography /Video Fluorometry» Part II. Applications« by | Dennis C./Shelly* Michael P./Vogarty and...Data EnlirtdJ REPORT DOCUMENTATION PAGE t. REPORT NUMBER 2 GOVT ACCESSION NO 4. T1TI.F (and Submit) lP-^fffsyva High Performance Liquid Chromatography

  1. Ethical Research Practices: Collaborative Action Research, Part II

    ERIC Educational Resources Information Center

    Calvin, Chris

    2004-01-01

    This is part II of a case study involving a large federally funded technology grant program implemented across several central Texas school districts and was followed by the researcher-participant at the university level as well as one of the campus sites. Many ethical research questions were raised during this study such as the use of participant…

  2. An analysis of the lumber planning process: Part II

    Treesearch

    Peter Koch

    1956-01-01

    This study is part II of an investigation pertaining to the peripheral-milling process of planing lumber. Some relationships were determined between cutterhead horsepower and various combinations of specimen, cutterhead, and feed factors. Power demand curves were interpreted through comparison with simultaneously taken one micro-second photos of the forming chips....

  3. Bioelectrochemical Reduction of Fe(II)EDTA-NO in a Biofilm Electrode Reactor: Performance, Mechanism, and Kinetics.

    PubMed

    Xia, Yinfeng; Zhao, Jingkai; Li, Meifang; Zhang, Shihan; Li, Sujing; Li, Wei

    2016-04-05

    A biofilm electrode reactor (BER) is proposed to effectively regenerate Fe(II)EDTA, a solvent for NOx removal from flue gas, from Fe(II)EDTA-NO, a spent solution. In this study, the performance, mechanism, and kinetics of the bioelectrochemical reduction of Fe(II)EDTA-NO were investigated. The pathways of Fe(II)EDTA-NO reduction were investigated via determination of nitrogen element balance in the BER and an abiotic electrode reactor. The experimental results indicate that the chelated NO (Fe(II)EDTA-NO) is reduced to N2 with N2O as an intermediate. However, the oxidation of NO occurred in the absence of Fe(II)EDTA in abiotic reactors. Furthermore, the accumulation of N2O was suppressed with the help of electricity. The preponderant electron donor for reduction of Fe(II)EDTA-NO was also confirmed via analysis of the electron conservation. About 87% of Fe(II)EDTA-NO was reduced using Fe(II)EDTA as the electron donor in the presence of both glucose and cathode electrons while the cathode electrons were utilized for the reduction of Fe(III)EDTA to Fe(II)EDTA. Michaelis-Menten kinetic constants of bioelectrochemical reduction of Fe(II)EDTA-NO were also calculated. The maximum reduction rate of Fe(II)EDTA-NO was 13.04 mol m(-3) h(-1), which is 50% higher than that in a conventional biofilter.

  4. Array of peptide-modified electrodes for the simultaneous determination of Pb(II), Cd(II) and Zn(II).

    PubMed

    Serrano, Núria; Prieto-Simón, Beatriz; Cetó, Xavier; Del Valle, Manel

    2014-07-01

    This paper reports the development of three peptide modified sensors in which glutathione (GSH) and its fragments Cys-Gly and γ-Glu-Cys were immobilized respectively through aryl diazonium electrochemical grafting onto the surface of graphite-epoxy composite electrodes (GEC), and used for the simultaneous determination of Cd(II), Pb(II) and Zn(II). The concentration interval ranged from 0.1 to 1.5 μmol L(-1) for each metal, and the technique used was differential pulse adsorptive stripping voltammetry. This study aimed to the comparison of the information provided by one single modified electrode at both fixed and multiple pH values (pH 6.8, 7.5 and 8.2) for the simultaneous determination of the three metals, with those supplied by the three-sensor array at multiple pH values. For the processing of the voltammograms, the fast Fourier transform was selected as the preprocessing tool for data compression coupled with an artificial neural network for the modeling of the obtained responses.

  5. 40 CFR Appendix II to Part 257 - Appendix II to Part 257

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to Part 257 A. Processes To Significantly Reduce Pathogens Aerobic digestion: The process is... of which temperatures average on a daily basis above 0 °C. Anaerobic digestion: The process is...: Liquid sludge is heated to temperatures of 180 °C for 30 minutes. Thermophilic Aerobic Digestion:...

  6. 40 CFR Appendix II to Part 257 - Appendix II to Part 257

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to Part 257 A. Processes To Significantly Reduce Pathogens Aerobic digestion: The process is... of which temperatures average on a daily basis above 0 °C. Anaerobic digestion: The process is...: Liquid sludge is heated to temperatures of 180 °C for 30 minutes. Thermophilic Aerobic Digestion:...

  7. 40 CFR Appendix II to Part 257 - Appendix II to Part 257

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to Part 257 A. Processes To Significantly Reduce Pathogens Aerobic digestion: The process is... of which temperatures average on a daily basis above 0 °C. Anaerobic digestion: The process is...: Liquid sludge is heated to temperatures of 180 °C for 30 minutes. Thermophilic Aerobic Digestion:...

  8. The Nature of Reinforcement: Part I. (Volume I), Part II. (Volume II).

    ERIC Educational Resources Information Center

    Glaser, Robert, Ed.

    Part One of this report describes the first half of a conference, designed to examine the nature of reinforcement, which was held at the University of Pittsburgh in June 1969. The topics discussed include: "Reward in Human Learning: Theoretical Issues and Strategic Choice Points"; "Are Reinforcement Concepts Able to Provide Reinforcement for…

  9. Copper(II) modified carbon paste electrodes based on self-assembled mercapto compounds-gold-nanoparticle.

    PubMed

    Mashhadizadeh, Mohammad Hossein; Eskandari, Khadijeh; Foroumadi, Alireza; Shafiee, Abbas

    2008-07-30

    Three mercapto compounds [2-mercapto-5-(1-methyl-5-nitroimidazole-2-yl)-1,3,4-thiadiazole] (MMNIT), [2-mercapto-5-(5-nitrofuran-2-yl)-1,3,4-thiadiazole] (MNFT) and [2-mercapto-5-(5-nitrothiophen-2-yl)-1,3,4-thidiazole] (MNTT) were used for self-assembled-gold nanoparticle (SAGNP) modified carbon paste electrodes. The electrodes were applied as indicator electrodes for potentiometric determination of Cu(II) ion. The prepared electrodes exhibit a Nernstian slope of 31.0+/-0.5 mV per decade for Cu(II) ion over a wide concentration range of 7.9x10(-9)-3.2x10(-2), 7.9x10(-9)-7.9x10(-4), and 2.8x10(-8)-7.9x10(-3) mol L(-1) for MMNIT, MNFT and, MNTT, respectively. The detection limits of electrodes were 3.5 (+/-0.2)x10(-9), 4.1x10(-9), and 4.1x10(-8) mol L(-1) of copper ion, respectively. The potentiometric responses of electrodes based on MMNIT, MNFT, and MNTT are independent of the pH of test solution in the pH range 2.0-5.5, 2.5-7.0, and 2.0-6.5, respectively. They have quick response with response time of about 5 s. The proposed electrodes show fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions. Finally, the proposed electrodes were successfully employed to detect Cu(II) ion in hair and water samples.

  10. The Value of Imaging Part II: Value beyond Image Interpretation.

    PubMed

    Duong, Phuong-Anh T; Pastel, David A; Sadigh, Gelareh; Ballard, David; Sullivan, Joseph C; Bresnahan, Brian; Buch, Karen; Duszak, Richard

    2016-01-01

    Although image interpretation is an essential part of radiologists' value, there are other ways in which we contribute to patient care. Part II of the value of imaging series reviews current initiatives that demonstrate value beyond the image interpretation. Standardizing processes, reducing the radiation dose of our examinations, clarifying written reports, improving communications with patients and providers, and promoting appropriate imaging through decision support are all ways we can provide safer, more consistent, and higher quality care. As payers and policy makers push to drive value, research that demonstrates the value of these endeavors, or lack thereof, will become increasingly sought after and supported.

  11. Probabilistic finite-state machines--part II.

    PubMed

    Vidal, Enrique; Thollard, Frank; de la Higuera, Colin; Casacuberta, Francisco; Carrasco, Rafael C

    2005-07-01

    Probabilistic finite-state machines are used today in a variety of areas in pattern recognition or in fields to which pattern recognition is linked. In Part I of this paper, we surveyed these objects and studied their properties. In this Part II, we study the relations between probabilistic finite-state automata and other well-known devices that generate strings like hidden Markov models and n-grams and provide theorems, algorithms, and properties that represent a current state of the art of these objects.

  12. Treatment of cellulite: Part II. Advances and controversies.

    PubMed

    Khan, Misbah H; Victor, Frank; Rao, Babar; Sadick, Neil S

    2010-03-01

    Treatments for localized adiposities range from topical creams to liposuction. Most treatments lack a substantial proof of efficacy. The unpredictable treatment outcome can be related to the fact that cellulite adipose tissue is physiologically and biochemically different from subcutaneous tissue found elsewhere in the body. Part II of this two-part series on cellulite reviews the various treatment options that are currently available for human adipose tissue including, but not limited to, cellulite. It also focuses on newer techniques that can be potentially useful in the future for the treatment of cellulite. Copyright 2010 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  13. Recent advances in small bowel diseases: Part II

    PubMed Central

    Thomson, Alan BR; Chopra, Angeli; Clandinin, Michael Tom; Freeman, Hugh

    2012-01-01

    As is the case in all areas of gastroenterology and hepatology, in 2009 and 2010 there were many advances in our knowledge and understanding of small intestinal diseases. Over 1000 publications were reviewed, and the important advances in basic science as well as clinical applications were considered. In Part II we review six topics: absorption, short bowel syndrome, smooth muscle function and intestinal motility, tumors, diagnostic imaging, and cystic fibrosis. PMID:22807605

  14. Feedback Flow Control for a Pitching Turret (Part II) (POSTPRINT)

    DTIC Science & Technology

    2010-01-01

    imposes no penalty on the control input. VII. Closed-loop Control Run with an Advanced Controller Three compensators ( LQR regulators with Kalman...AFRL-RB-WP-TP-2010-3024 FEEDBACK FLOW CONTROL FOR A PITCHING TURRET (PART II) (POSTPRINT) T. Vaithianathan and H.A. Carlson Clear...display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YY) 2. REPORT TYPE 3

  15. Feasibility of Screening for Antibiotic Resistance-Part II

    DTIC Science & Technology

    2005-08-01

    antibiotic resistance - T +31 15 28 43000 F +31 152843991 part II Info-DenV@tno.nl Date August 2005 Author(s) M.P. Broekhuijsen, W.C.M. van Dijk...ciprofloxacineresistentie. Beide, De ontworpen methode kan nog verder methoden werden getest op kunstmatig worden verbeterd, en worden toegepast op een resistent ...resultaat te zettn. c otworen ethd erken ood behalen is. Deze mutatie-analysemethode is op de twee kunstmatig resistent gemaalcte tevens geschikter voor

  16. Ag Nanoparticles Drop-Casting Modification of Screen-Printed Electrodes for the Simultaneous Voltammetric Determination of Cu(II) and Pb(II)

    PubMed Central

    Pérez-Ràfols, Clara; Bastos-Arrieta, Julio; Serrano, Núria; Díaz-Cruz, José Manuel; Ariño, Cristina; de Pablo, Joan; Esteban, Miquel

    2017-01-01

    A new silver nanoparticle modified screen-printed electrode was developed and applied to the simultaneous determination of Pb(II) and Cu(II). Two different types of silver nanoparticles with different shapes and sizes, Ag nanoseeds and Ag nanoprisms, were microscopically characterized and three different carbon substrates, graphite, graphene and carbon nanofibers, were tested. The best analytical performance was achieved for the combination of Ag nanoseeds with a carbon nanofiber modified screen-printed electrode. The resulting sensor allowed the simultaneous determination of Pb(II) and Cu(II) at trace levels and its applicability to natural samples was successfully tested with a groundwater certified reference material, presenting high reproducibility and trueness. PMID:28635631

  17. Ag Nanoparticles Drop-Casting Modification of Screen-Printed Electrodes for the Simultaneous Voltammetric Determination of Cu(II) and Pb(II).

    PubMed

    Pérez-Ràfols, Clara; Bastos-Arrieta, Julio; Serrano, Núria; Díaz-Cruz, José Manuel; Ariño, Cristina; de Pablo, Joan; Esteban, Miquel

    2017-06-21

    A new silver nanoparticle modified screen-printed electrode was developed and applied to the simultaneous determination of Pb(II) and Cu(II). Two different types of silver nanoparticles with different shapes and sizes, Ag nanoseeds and Ag nanoprisms, were microscopically characterized and three different carbon substrates, graphite, graphene and carbon nanofibers, were tested. The best analytical performance was achieved for the combination of Ag nanoseeds with a carbon nanofiber modified screen-printed electrode. The resulting sensor allowed the simultaneous determination of Pb(II) and Cu(II) at trace levels and its applicability to natural samples was successfully tested with a groundwater certified reference material, presenting high reproducibility and trueness.

  18. Sputtered bismuth screen-printed electrode: a promising alternative to other bismuth modifications in the voltammetric determination of Cd(II) and Pb(II) ions in groundwater.

    PubMed

    Sosa, Velia; Serrano, Núria; Ariño, Cristina; Díaz-Cruz, José Manuel; Esteban, Miquel

    2014-02-01

    A commercially available sputtered bismuth screen-printed electrode (BispSPE) has been pioneeringly applied for the simultaneous determination of Cd(II) and Pb(II) ions in a certified groundwater sample by means of differential pulse anodic stripping voltammetry (DPASV) as an alternative to more conventional bismuth screen-printed carbon electrodes (BiSPCEs). BispSPEs can be used for a large set of measurements without any previous plating or activation. The obtained detection and quantification limits suggest that BispSPEs produce a better analytical performance as compared to In-situ BiSPCE for Pb(II) and Cd(II) determination, but also to Ex-situ BiSPCE for Cd(II) determination. The results confirm the applicability of these devices for the determination of low level concentrations of these metal ions in natural samples with very high reproducibility (0.7% and 2.5% for Pb(II) and Cd(II) respectively), and good trueness (0.3% and 2.4% for Pb(II) and Cd(II) respectively).

  19. Gas Atomization of Amorphous Aluminum Powder: Part II. Experimental Investigation

    NASA Astrophysics Data System (ADS)

    Zheng, Baolong; Lin, Yaojun; Zhou, Yizhang; Lavernia, Enrique J.

    2009-12-01

    The optimal processing parameters that are required to atomize amorphous Al were established on the basis of numerical simulations in part I of this study. In this part II, the characterization of cooling rate experienced by gas-atomized, Al-based amorphous powders was studied via experiments. An experimental investigation was implemented to validate the numerical predictions reported in part I of this study. The cooling rate experienced by the powders, for example, was experimentally determined on the basis of dendrite arm spacing correlations, and the results were compared with the numerical predictions. The experimental studies were completed using commercial Al 2024 as a baseline material and Al90Gd7Ni2Fe1 metallic glass (MG). The results showed that the cooling rate of droplets increases with decreasing particle size, with an increasing proportion of helium in the atomization gas and with increasing melt superheat. The experimental results reported in this article suggest good agreement between experiments and numerical simulations.

  20. Polycystic ovary syndrome: a review for dermatologists: Part II. Treatment.

    PubMed

    Buzney, Elizabeth; Sheu, Johanna; Buzney, Catherine; Reynolds, Rachel V

    2014-11-01

    Dermatologists are in a key position to treat the manifestations of polycystic ovary syndrome (PCOS). The management of PCOS should be tailored to each woman's specific goals, reproductive interests, and particular constellation of symptoms. Therefore, a multidisciplinary approach is recommended. In part II of this continuing medical education article, we present the available safety and efficacy data regarding treatments for women with acne, hirsutism, and androgenetic alopecia. Therapies discussed include lifestyle modification, topical therapies, combined oral contraceptives, antiandrogen agents, and insulin-sensitizing drugs. Treatment recommendations are made based on the current available evidence.

  1. Zinc/air battery R and D research and development of bifunctional oxygen electrode: Tasks I and II, Final report

    SciTech Connect

    Klein, M.; Viswanathan, S.

    1986-12-01

    Studies were conducted of the bifunctional oxygen electrode. The development of a rechargeable metal-oxygen (air) cell has been hampered to a great extent by the lack of a stable and cost effective oxygen electrode capable of use during both charge and discharge. The first type of bifunctional electrode consists of two distinct catalytifc layers. The oxygen reduction catalyst layer containing a supported gold catalyst is in contact with a hydrophilic nickel layer in which evolution of oxygen takes place. Loadings of gold from 0.5 to 1.0 mg/cm/sup 2/ were investigated; carbon, graphite, metal, and spinel oxides were evaluated as substrates. The second part of the research effort was centered on developing a reversible oxygen electrode containing only one catalytic layer for both reduction and evolution of oxygen. The work was directed specifically to the study of perovskite type of oxides with the composition AA/sup 1/BO/sub 3/ where A is an element of the lanthanide series, A/sup 1/ is an alkaline earth metal and B, a first row transition element. Initial polarization data obtained in unscrubbed air gave a value of approximately 200 millivolts vs Hg/HgO reference electrode at a current density of 50 ma/cm/sup 2/. Electrodes were made both by roll-bonding and by pelletizing techniques and tested for polarization and cycle life. This study also indicates the optimum process conditions for the manufacture of oxides and fabrication of electrodes.

  2. The effective determination of Cd(ii) and Pb(ii) simultaneously based on an aluminum silicon carbide-reduced graphene oxide nanocomposite electrode.

    PubMed

    Wu, Yale; Yang, Tao; Chou, Kuo-Chih; Chen, Junhong; Su, Lei; Hou, Xinmei

    2017-07-24

    A platform for the simultaneous determination of Cd(ii) and Pb(ii) in aqueous solution has been applied based on an aluminum silicon carbide-reduced graphene oxide nanocomposite (Al4SiC4-RGO) modified bismuth film glassy carbon electrode (GCE) using square wave anodic stripping voltammetry (SWASV) for the first time. The Al4SiC4-RGO nanocomposite electrode was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Compared with the Al4SiC4 modified GCE and bare GCE, the electrochemical performance of the Al4SiC4-RGO nanocomposite electrode is obviously enhanced resulting from the synergistic effects of Al4SiC4, RGO and bismuth film. The chemical and electrochemical parameters that exert an influence on the deposition and stripping of metal ions, such as supporting electrolytes, pH values, concentrations of Bi(3+), deposition potentials and deposition times, were carefully studied. Under optimal conditions, a linear relationship exists between the currents and the concentrations of Cd(ii) and Pb(ii) in the range of 50 to 2700 μg L(-1). The limits of detection (S/N = 3) are estimated to be 1.30 μg L(-1) for Pb(ii) and 2.15 μg L(-1) for Cd(ii). Compared with the related work reported in the literature, the analytical performance in this work has a lower determination limit and a wider detection linear range. In addition, this electrode also exhibits good stability and reproducibility. These results imply that the Al4SiC4-RGO nanocomposite might be a promising candidate for practical applications in the electrochemical detection of metal ions.

  3. The "Pseudocommando" mass murderer: part II, the language of revenge.

    PubMed

    Knoll, James L

    2010-01-01

    In Part I of this article, research on pseudocommandos was reviewed, and the important role that revenge fantasies play in motivating such persons to commit mass murder-suicide was discussed. Before carrying out their mass shootings, pseudocommandos may communicate some final message to the public or news media. These communications are rich sources of data about their motives and psychopathology. In Part II of this article, forensic psycholinguistic analysis is applied to clarify the primary motivations, detect the presence of mental illness, and discern important individual differences in the final communications of two recent pseudocommandos: Seung-Hui Cho (Virginia Tech) and Jiverly Wong (Binghamton, NY). Although both men committed offenses that qualify them as pseudocommandos, their final communications reveal striking differences in their psychopathology.

  4. CE and nanomaterials - Part II: Nanomaterials in CE.

    PubMed

    Adam, Vojtech; Vaculovicova, Marketa

    2017-10-01

    The scope of this two-part review is to summarize publications dealing with CE and nanomaterials together. This topic can be viewed from two broad perspectives, and this article is trying to highlight these two approaches: (i) CE of nanomaterials, and (ii) nanomaterials in CE. The second part aims at summarization of publications dealing with application of nanomaterials for enhancement of CE performance either in terms of increasing the separation resolution or for improvement of the detection. To increase the resolution, nanomaterials are employed as either surface modification of the capillary wall forming open tubular column or as additives to the separation electrolyte resulting in a pseudostationary phase. Moreover, nanomaterials have proven to be very beneficial for increasing also the sensitivity of detection employed in CE or even they enable the detection (e.g., fluorescent tags of nonfluorescent molecules). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Repair of articular cartilage defects: part II. Treatment options.

    PubMed

    Chen, F S; Frenkel, S R; Di Cesare, P E

    1999-02-01

    Articular cartilage injuries result in numerous clinical symptoms, such as pain and decreased functional levels. Current therapeutic options being used include articular surface debridement, such as chondral shaving, abrasion chondroplasty, and subchondral perforation; soft-tissue arthroplasties, such as perichondrial and periosteal grafts; and osteochondral transplantation. None of these therapies, however, has resulted in the successful regeneration of a hyaline-like tissue that withstands normal joint loading and activity over prolonged periods. As a result, research is also being conducted on alternative therapeutic procedures to enhance the repair process and to stimulate the regeneration of a repair tissue with hyaline-like structural and biologic properties. Part I of this paper, which was published in January, discussed the basic science of cartilage healing. Part II presents the treatment options.

  6. Structure Learning and Statistical Estimation in Distribution Networks - Part II

    SciTech Connect

    Deka, Deepjyoti; Backhaus, Scott N.; Chertkov, Michael

    2015-02-13

    Limited placement of real-time monitoring devices in the distribution grid, recent trends notwithstanding, has prevented the easy implementation of demand-response and other smart grid applications. Part I of this paper discusses the problem of learning the operational structure of the grid from nodal voltage measurements. In this work (Part II), the learning of the operational radial structure is coupled with the problem of estimating nodal consumption statistics and inferring the line parameters in the grid. Based on a Linear-Coupled(LC) approximation of AC power flows equations, polynomial time algorithms are designed to identify the structure and estimate nodal load characteristics and/or line parameters in the grid using the available nodal voltage measurements. Then the structure learning algorithm is extended to cases with missing data, where available observations are limited to a fraction of the grid nodes. The efficacy of the presented algorithms are demonstrated through simulations on several distribution test cases.

  7. [The Mexican consensus on gastroesophageal reflux disease. Part II].

    PubMed

    Huerta-Iga, F; Tamayo-de la Cuesta, J L; Noble-Lugo, A; Hernández-Guerrero, A; Torres-Villalobos, G; Ramos-de la Medina, A; Pantoja-Millán, J P

    2013-01-01

    To update the themes of endoscopic and surgical treatment of Gastroesophageal Reflux Disease (GERD) from the Mexican Consensus published in 2002. Part I of the 2011 Consensus dealt with the general concepts, diagnosis, and medical treatment of this disease. Part II covers the topics of the endoscopic and surgical treatment of GERD. In this second part, an expert in endoscopy and an expert in GERD surgery, along with the three general coordinators of the consensus, carried out an extensive bibliographic review using the Embase, Cochrane, and Medline databases. Statements referring to the main aspects of endoscopic and surgical treatment of this disease were elaborated and submitted to specialists for their consideration and vote, utilizing the modified Delphi method. The statements were accepted into the consensus if the level of agreement was 67% or higher. Twenty-five statements corresponding to the endoscopic and surgical treatment of GERD resulted from the voting process, and they are presented herein as Part II of the consensus. The majority of the statements had an average level of agreement approaching 90%. Currently, endoscopic treatment of GERD should not be regarded as an option, given that the clinical results at 3 and 5 years have not demonstrated durability or sustained symptom remission. The surgical indications for GERD are well established; only those patients meeting the full criteria should be candidates and their surgery should be performed by experts. Copyright © 2012 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.

  8. PREREM: an interactive data preprocessing code for INREM II. Part I: user's manual. Part II: code structure

    SciTech Connect

    Ryan, M.T.; Fields, D.E.

    1981-05-01

    PREREM is an interactive computer code developed as a data preprocessor for the INREM-II (Killough, Dunning, and Pleasant, 1978a) internal dose program. PREREM is intended to provide easy access to current and self-consistent nuclear decay and radionuclide-specific metabolic data sets. Provision is made for revision of metabolic data, and the code is intended for both production and research applications. Documentation for the code is in two parts. Part I is a user's manual which emphasizes interpretation of program prompts and choice of user input. Part II stresses internal structure and flow of program control and is intended to assist the researcher who wishes to revise or modify the code or add to its capabilities. PREREM is written for execution on a Digital Equipment Corporation PDP-10 System and much of the code will require revision before it can be run on other machines. The source program length is 950 lines (116 blocks) and computer core required for execution is 212 K bytes. The user must also have sufficient file space for metabolic and S-factor data sets. Further, 64 100 K byte blocks of computer storage space are required for the nuclear decay data file. Computer storage space must also be available for any output files produced during the PREREM execution. 9 refs., 8 tabs.

  9. Blade System Design Study. Part II, final project report (GEC).

    SciTech Connect

    Griffin, Dayton A.

    2009-05-01

    As part of the U.S. Department of Energy's Low Wind Speed Turbine program, Global Energy Concepts LLC (GEC)1 has studied alternative composite materials for wind turbine blades in the multi-megawatt size range. This work in one of the Blade System Design Studies (BSDS) funded through Sandia National Laboratories. The BSDS program was conducted in two phases. In the Part I BSDS, GEC assessed candidate innovations in composite materials, manufacturing processes, and structural configurations. GEC also made recommendations for testing composite coupons, details, assemblies, and blade substructures to be carried out in the Part II study (BSDS-II). The BSDS-II contract period began in May 2003, and testing was initiated in June 2004. The current report summarizes the results from the BSDS-II test program. Composite materials evaluated include carbon fiber in both pre-impregnated and vacuum-assisted resin transfer molding (VARTM) forms. Initial thin-coupon static testing included a wide range of parameters, including variation in manufacturer, fiber tow size, fabric architecture, and resin type. A smaller set of these materials and process types was also evaluated in thin-coupon fatigue testing, and in ply-drop and ply-transition panels. The majority of materials used epoxy resin, with vinyl ester (VE) resin also used for selected cases. Late in the project, testing of unidirectional fiberglass was added to provide an updated baseline against which to evaluate the carbon material performance. Numerous unidirectional carbon fabrics were considered for evaluation with VARTM infusion. All but one fabric style considered suffered either from poor infusibility or waviness of fibers combined with poor compaction. The exception was a triaxial carbon-fiberglass fabric produced by SAERTEX. This fabric became the primary choice for infused articles throughout the test program. The generally positive results obtained in this program for the SAERTEX material have led to its being

  10. How to overcome inter-electrode variability and instability to quantify dissolved oxygen, Fe(II), mn(II), and S(−II) in undisturbed soils and sediments using voltammetry

    USGS Publications Warehouse

    Slowey, Aaron J.; Marvin-DiPasquale, Mark

    2012-01-01

    Conclusions - Despite their intrinsic variability, Hg/Au electrodes fabricated by hand can be used to quantify O2, S(−II), Fe(II), and Mn(II) without calibrating every electrode for every constituent of interest. The pilot ion method can achieve accuracies to within 20% or less, provided that the underlying principle—the independence of slope ratios—is demonstrated for all voltammetric techniques used, and effects of the physicochemical properties of the system on voltammetric signals are addressed through baseline subtraction.

  11. How to overcome inter-electrode variability and instability to quantify dissolved oxygen, Fe(II), mn(II), and S(−II) in undisturbed soils and sediments using voltammetry

    PubMed Central

    2012-01-01

    Background Although uniquely capable of measuring multiple redox constituents nearly simultaneously with no or minimal sample pretreatment, voltammetry is currently underutilized in characterizing redox conditions in aquatic and terrestrial systems. Investigation of undisturbed media such as pore water requires a solid-state electrode, and such electrodes can be difficult to fabricate reproducibly. An approach to determine the concentrations of electroactive constituents using indirectly calibrated electrodes has been developed, but the protocol for and accuracy of this approach—the pilot ion method—has not been documented in detail. Results A detailed procedure for testing electrode quality is provided, and the application and limitations of the pilot ion method have been documented. To quantify Fe(II) and Mn(II), subtraction of non-linear baseline functions from voltammetric signals produced better calibration curves than did linear baselines, enabled lower detection limits and reliable deconvolution of overlapping signals, and was successfully applied to sediment pore water signals. We observed that electrode sensitivities often vary by tens of percent, and that the sensitivity declines over time. The ratio of calibration slopes of Mn(II) to Fe(II) varied by no more than 11% from one Hg/Au electrode to another and Fe(II) concentrations predicted by the Mn(II) pilot ion were, on average, 13% different from their actual values. However, concentration predictions by the pilot ion method were worse for less than 15 μM Fe(II) (46% different on average). The ratio of calibration slopes of Mn(II) to S(−II) varied by almost 20% from one Hg/Au electrode to another, and S(−II) predicted concentrations were as much as 58% different from their actual values. These predictions of Fe(II) and S(−II) concentrations indicate that the accuracy of the pilot ion method depends on how independent calibration slope ratios are from the electrode used. At medium

  12. A Survey of Optometry Graduates to Determine Practice Patterns: Part II: Licensure and Practice Establishment Experiences.

    ERIC Educational Resources Information Center

    Bleimann, Robert L.; Smith, Lee W.

    1985-01-01

    A summary of Part II of a two-volume study of optometry graduates conducted by the Association of Schools and Colleges of Optometry is presented. Part II includes the analysis of the graduates' licensure and practice establishment experiences. (MLW)

  13. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Duty Cycles for Laboratory Testing II Appendix II to Part 1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld...

  14. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Duty Cycles for Laboratory Testing II Appendix II to Part 1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld...

  15. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty Cycles for Laboratory Testing II Appendix II to Part 1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld...

  16. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Duty Cycles for Laboratory Testing II Appendix II to Part 1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld...

  17. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Duty Cycles for Laboratory Testing II Appendix II to Part 1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld...

  18. 31 CFR Appendix II(f) to Part 13 - Overhead and Administrative Costs

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Overhead and Administrative Costs II(F) Appendix II(F) to Part 13 Money and Finance: Treasury Office of the Secretary of the Treasury... Pt. 13, App. II(F) Appendix II(F) to Part 13—Overhead and Administrative Costs Date: Select Only...

  19. 31 CFR Appendix II(f) to Part 13 - Overhead and Administrative Costs

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance: Treasury 1 2011-07-01 2011-07-01 false Overhead and Administrative Costs II(F) Appendix II(F) to Part 13 Money and Finance: Treasury Office of the Secretary of the Treasury... Pt. 13, App. II(F) Appendix II(F) to Part 13—Overhead and Administrative Costs Date: Select Only...

  20. 12 CFR Appendix II to Part 27 - Information for Government Monitoring Purposes

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Information for Government Monitoring Purposes II Appendix II to Part 27 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY FAIR HOUSING HOME LOAN DATA SYSTEM Pt. 27, App. II Appendix II to Part 27—Information for Government...

  1. 40 CFR Appendix II to Part 92 - Interpretive Ruling for § 92.705-Remedial Plans

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-Remedial Plans II Appendix II to Part 92 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY..., App. II Appendix II to Part 92—Interpretive Ruling for § 92.705—Remedial Plans The following is an... manufacturers to better enable them to submit acceptable remedial plans. (2) Section 207(c)(1) requires the...

  2. 10 CFR Appendix II to Part 960 - NRC and EPA Requirements for Preclosure Repository Performance

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false NRC and EPA Requirements for Preclosure Repository Performance II Appendix II to Part 960 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Pt. 960, App. II Appendix II to Part 960—NRC...

  3. 10 CFR Appendix II to Part 960 - NRC and EPA Requirements for Preclosure Repository Performance

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false NRC and EPA Requirements for Preclosure Repository Performance II Appendix II to Part 960 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Pt. 960, App. II Appendix II to Part 960—NRC...

  4. 10 CFR Appendix II to Part 960 - NRC and EPA Requirements for Preclosure Repository Performance

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false NRC and EPA Requirements for Preclosure Repository Performance II Appendix II to Part 960 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Pt. 960, App. II Appendix II to Part 960—NRC...

  5. 10 CFR Appendix II to Part 960 - NRC and EPA Requirements for Preclosure Repository Performance

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false NRC and EPA Requirements for Preclosure Repository Performance II Appendix II to Part 960 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Pt. 960, App. II Appendix II to Part 960—NRC...

  6. 10 CFR Appendix II to Part 960 - NRC and EPA Requirements for Preclosure Repository Performance

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false NRC and EPA Requirements for Preclosure Repository Performance II Appendix II to Part 960 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Pt. 960, App. II Appendix II to Part 960—NRC...

  7. Trace analysis of cefotaxime at carbon paste electrode modified with novel Schiff base Zn(II) complex.

    PubMed

    Nigam, Preeti; Mohan, Swati; Kundu, Subir; Prakash, Rajiv

    2009-02-15

    Cefotaxime a third generation cephalosporin drug estimation in nanomolar concentration range is demonstrated for the first time in aqueous and human blood samples using novel Schiff base octahedral Zn(II) complex. The cefotaxime electrochemistry is studied over graphite paste and Zn(II) complex modified graphite paste capillary electrodes in H(2)SO(4) (pH 2.3) using cyclic voltammetry and differential pulse voltammetry. Cefotaxime enrichment is observed over Zn(II) complex modified graphite paste electrode probably due to interaction of functional groups of cefotaxime with Zn(II) complex. Possible interactions between metal complex and cefotaxime drug is examined by UV-vis and electrochemical quartz crystal microbalance (EQCM) techniques and further supported by voltammetric analysis. Differential pulse voltammetry (DPV) with modified electrode is applied for the determination of cefotaxime in acidified aqueous and blood samples. Cefotaxime estimation is successfully demonstrated in the range of 1-500 nM for aqueous samples and 0.1-100 microM in human blood samples. Reproducibility, accuracy and repeatability of the method are checked by triplicate reading for large number of samples. The variation in the measurements is obtained less than 10% without any interference of electrolyte or blood constituents.

  8. Electrochemical treatment of Orange II dye solution--use of aluminum sacrificial electrodes and floc characterization.

    PubMed

    Mollah, M Yousuf A; Gomes, Jewel A G; Das, Kamol K; Cocke, David L

    2010-02-15

    Electrocoagulation (EC) of Orange II dye in a flow through cell with aluminum as sacrificial electrodes was carried out under varying conditions of dye concentration, current density, flow rate, conductivity, and the initial pH of the solution in order to optimize the operating parameters for maximum benefits. Maximum removal efficiency of 94.5% was obtained at the following conditions: dye concentration=10 ppm, current density=160 A/m(2), initial pH 6.5, conductance=7.1 mS/cm, flow rate=350 mL/min, and concentration of added NaCl=4.0 g/L of dye solution. The EC-floc was characterized using Fourier transform infrared spectroscopy, scanning electron microscopy/energy dispersive X-ray spectroscopy, and powder X-ray diffraction techniques. The removal mechanism has been proposed that is in compliance with the Pourbaix diagram, solubility curve of aluminum oxides/hydroxides, and physico-chemical properties of the EC-floc.

  9. Mammalian Toxicity of Munitions Compounds. Phase II. Effects of Multiple Doses Part II. 2,4-Dinitrotoluene

    DTIC Science & Technology

    1978-11-01

    II: Effects of Multiple Doses Part !I: 2,4-T)initrotoiuene I Progres Report No. 3 oNovember 1978 by 3I Cheng-Chun Lee U Hirty V. Ellis, III Jo.,n J...Sciences Division November 1978 vii :. •I~~~~AMMALIAN TOXICITY OF MUNITIONS COMPOUNDS ... ... PHASE IIz Effects of Multiple Doses m . ............... PART...161 xi MAMOMALIAN TOXICITY OF MUNITION COMPOUNDS PHASE II: Effects of Multiple Dones PART II: 2,4

  10. 49 CFR Appendix A-Ii to Part 541 - Lines With Antitheft Devices Which Are Exempted in-Part From the Parts-Marking Requirements of...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Lines With Antitheft Devices Which Are Exempted in-Part From the Parts-Marking Requirements of This Standard Pursuant to 49 CFR Part 543 A Appendix A-II... STANDARD Pt. 541, App. A-II Appendix A-II to Part 541—Lines With Antitheft Devices Which Are Exempted...

  11. 49 CFR Appendix A-Ii to Part 541 - Lines With Antitheft Devices Which Are Exempted in-Part From the Parts-Marking Requirements of...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false Lines With Antitheft Devices Which Are Exempted in-Part From the Parts-Marking Requirements of This Standard Pursuant to 49 CFR Part 543 A Appendix A-II... STANDARD Pt. 541, App. A-II Appendix A-II to Part 541—Lines With Antitheft Devices Which Are Exempted...

  12. 77 FR 60743 - Proposed Collection; Comment Request for Schedule F, Part II and III (Form 1040)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-04

    ... Internal Revenue Service Proposed Collection; Comment Request for Schedule F, Part II and III (Form 1040... Law 104-13 (44 U.S.C. 3506(c)(2)(A)). Currently, the IRS is soliciting comments concerning Schedule F... Number: Schedule F, Part II and III (Form 1040). Abstract: Schedule F, Part II and III (Form 1040)...

  13. Fast transforms for acoustic imaging--part II: applications.

    PubMed

    Ribeiro, Flávio P; Nascimento, Vítor H

    2011-08-01

    In Part I ["Fast Transforms for Acoustic Imaging-Part I: Theory," IEEE Transactions on Image Processing], we introduced the Kronecker array transform (KAT), a fast transform for imaging with separable arrays. Given a source distribution, the KAT produces the spectral matrix which would be measured by a separable sensor array. In Part II, we establish connections between the KAT, beamforming and 2-D convolutions, and show how these results can be used to accelerate classical and state of the art array imaging algorithms. We also propose using the KAT to accelerate general purpose regularized least-squares solvers. Using this approach, we avoid ill-conditioned deconvolution steps and obtain more accurate reconstructions than previously possible, while maintaining low computational costs. We also show how the KAT performs when imaging near-field source distributions, and illustrate the trade-off between accuracy and computational complexity. Finally, we show that separable designs can deliver accuracy competitive with multi-arm logarithmic spiral geometries, while having the computational advantages of the KAT.

  14. Antiviral medication in sexually transmitted diseases. Part II: HIV.

    PubMed

    Majewska, Anna; Mlynarczyk-Bonikowska, Beata; Malejczyk, Magdalena; Mlynarczyk, Grazyna; Majewski, Slawomir

    2015-01-01

    This is a second part of a review under a main title Antiviral medication in sexually transmitted diseases. In the part we published in Mini Rev Med Chem. 2013,13(13):1837-45, we have described mechanisms of action and mechanism of resistance to antiviral agents used in genital herpes and genital HPV infection. The Part II review focuses on therapeutic options in HIV infection. In 1987, 6 years after the recognition of AIDS, the FDA approved the first drug against HIV--zidovudine. Since then a lot of antiretroviral drugs are available. The most effective treatment for HIV is highly active antiretroviral therapy--a combination of several antiretroviral medicines that cause a reduction of HIV blood concentration and often results in substantial recovery of impaired immunologic function. At present, there are over 20 drugs licensed and used for the treatment of HIV/AIDS, and these drugs are divided into one of six classes. Investigational agents include GS-7340, the prodrug of tenofovir and BMS-663068--the first in a novel class of drugs that blocks the binding of the HIV gp120 to the CD4 receptor.

  15. Bayesian inference for psychology. Part II: Example applications with JASP.

    PubMed

    Wagenmakers, Eric-Jan; Love, Jonathon; Marsman, Maarten; Jamil, Tahira; Ly, Alexander; Verhagen, Josine; Selker, Ravi; Gronau, Quentin F; Dropmann, Damian; Boutin, Bruno; Meerhoff, Frans; Knight, Patrick; Raj, Akash; van Kesteren, Erik-Jan; van Doorn, Johnny; Šmíra, Martin; Epskamp, Sacha; Etz, Alexander; Matzke, Dora; de Jong, Tim; van den Bergh, Don; Sarafoglou, Alexandra; Steingroever, Helen; Derks, Koen; Rouder, Jeffrey N; Morey, Richard D

    2017-07-06

    Bayesian hypothesis testing presents an attractive alternative to p value hypothesis testing. Part I of this series outlined several advantages of Bayesian hypothesis testing, including the ability to quantify evidence and the ability to monitor and update this evidence as data come in, without the need to know the intention with which the data were collected. Despite these and other practical advantages, Bayesian hypothesis tests are still reported relatively rarely. An important impediment to the widespread adoption of Bayesian tests is arguably the lack of user-friendly software for the run-of-the-mill statistical problems that confront psychologists for the analysis of almost every experiment: the t-test, ANOVA, correlation, regression, and contingency tables. In Part II of this series we introduce JASP ( http://www.jasp-stats.org ), an open-source, cross-platform, user-friendly graphical software package that allows users to carry out Bayesian hypothesis tests for standard statistical problems. JASP is based in part on the Bayesian analyses implemented in Morey and Rouder's BayesFactor package for R. Armed with JASP, the practical advantages of Bayesian hypothesis testing are only a mouse click away.

  16. What's new in pediatric dermatology?: part II. Treatment.

    PubMed

    Pride, Howard B; Tollefson, Megha; Silverman, Robert

    2013-06-01

    The field of pediatric dermatology has been rich in new developments. Part II of this continuing medical education article will focus on new therapeutic modalities for several entities encountered in pediatric dermatology. The treatment of atopic dermatitis, exciting advances in the use of propranolol and other beta-blockers for the use of infantile hemangiomas, the use of rapamycin for vascular anomalies, the use of biologics in children, the central nervous system risks of general anesthesia in young children, side effects in the use of isotretinoin, the treatment of tinea capitis, treatment of herpes simplex infections, and the use of technologies such as texting and social media in medicine will be discussed. Copyright © 2013 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  17. Primer of statistics in dental research: Part II.

    PubMed

    Shintani, Ayumi

    2014-04-01

    The Part I of Primer of Statistics in Dental Research covered five topics that are often mentioned in statistical check list of many peer-review journals including (1) statistical graph, (2) how to deal with outliers, (3) p-value and confidence interval, (4) testing equivalence, and (5) multiplicity Adjustment. The Part II of the series covers another set of important topics in dental statistics including (1) selecting the proper statistical tests, (2) repeated measures analysis, (3) epidemiological consideration for causal association, and (4) analysis of agreement. First, a guide in selecting the proper statistical tests based on the research question will be laid out in text and with a table so that researchers choose the univariable statistical test by answering five simple questions. Second, the importance of utilizing repeated measures analysis will be illustrated. This is a key component of data analysis as in many dental studies, observations are considered repeated in a single patient (several teeth are measured in a single patient). Third, concepts of confounding and the use of regression analysis are explained by going over a famous observational cohort study. Lastly, the use of proper agreement analysis vs. correlation for study of agreement will be discussed to avoid a common pitfall in dental research.

  18. Digital Assays Part II: Digital Protein and Cell Assays.

    PubMed

    Basu, Amar S

    2017-08-01

    A digital assay is one in which the sample is partitioned into many containers such that each partition contains a discrete number of biological entities (0, 1, 2, 3, . . .). A powerful technique in the biologist's toolkit, digital assays bring a new level of precision in quantifying nucleic acids, measuring proteins and their enzymatic activity, and probing single-cell genotype and phenotype. Where part I of this review focused on the fundamentals of partitioning and digital PCR, part II turns its attention to digital protein and cell assays. Digital enzyme assays measure the kinetics of single proteins with enzymatic activity. Digital enzyme-linked immunoassays (ELISAs) quantify antigenic proteins with 2 to 3 log lower detection limit than conventional ELISA, making them well suited for low-abundance biomarkers. Digital cell assays probe single-cell genotype and phenotype, including gene expression, intracellular and surface proteins, metabolic activity, cytotoxicity, and transcriptomes (scRNA-seq). These methods exploit partitioning to 1) isolate single cells or proteins, 2) detect their activity via enzymatic amplification, and 3) tag them individually by coencapsulating them with molecular barcodes. When scaled, digital assays reveal stochastic differences between proteins or cells within a population, a key to understanding biological heterogeneity. This review is intended to give a broad perspective to scientists interested in adopting digital assays into their workflows.

  19. Violence in the emergency department: an ethnographic study (part II).

    PubMed

    Lau, Jacqui Bee Chuo; Magarey, Judy; Wiechula, Richard

    2012-07-01

    Violence in the emergency department (ED) is a significant and complex problem worldwide. This is a part II of a 2-part series on an ethnographic study. The study which aimed at exploring the cultural aspects of violence was carried out at a major metropolitan ED for 3 months. This paper presents the findings and discussions of the study. One hundred and three violent incident questionnaires were completed. A total of 242.5h of observation and 34 (33%) interviews with nurses were conducted. From the data analysis, three critical cultural themes (i.e. 'problems and solutions', 'requests and demands' and 'them and us') were identified. The study indicated that the cultural meanings of violence were complex and highly subjective. Factors such as environment, conflicting messages regarding waiting time, and the nurse-patient/relative behaviours and the resulting reciprocal relationships were critical. Nurses' efforts to establish rapport with patients was crucial and needed to occur early. There was usually a 'turning point' that provided an opportunity for the nurse to avoid violence. While violence is a complex issue with many paradoxes, the study indicates that effective interpersonal empathetic communication has a significant role in reducing violence in the ED. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. High-Temperature Kicker Electrodes for High-Beam-Current Operation of PEP-II

    SciTech Connect

    Wienands, U.

    2005-04-11

    The strip line electrodes of the kickers used in the transverse bunch-by-bunch feedback systems see significant power deposition by beam and HOM-induced currents. This leads to elevated temperatures of the aluminum electrodes and will ultimately become a limit for the beam current in the Low Energy Ring. Heat is transported to the environment primarily by radiation from the blackened surface of the electrodes. In order to extend the beam-current range of these kickers, new electrodes have been fabricated from molybdenum which are able to run at significantly higher temperature, thus greatly increasing the efficiency of the radiative cooling of the electrodes. Blackening of the electrodes is achieved by oxidation in air at 530 C (1000 F) using a recipe first applied in aviation research for supersonic aircraft. Emissivity was measured on coupons and a whole electrode to be about 0.6. In addition, the match at the terminations of the electrodes is improved following field calculations and measurements on a model of the kicker.

  1. Reforming Science Education: Part II. Utilizing Kieran Egan's Educational Metatheory

    NASA Astrophysics Data System (ADS)

    Schulz, Roland M.

    2009-04-01

    This paper is the second of two parts and continues the conversation which had called for a shift in the conceptual focus of science education towards philosophy of education, with the requirement to develop a discipline-specific “philosophy” of science education. In Part I, conflicting conceptions of science literacy were identified with disparate “visions” tied to competing research programs as well as school-based curricular paradigms. The impasse in the goals of science education and thereto, the contending views of science literacy, were themselves associated with three underlying fundamental aims of education (knowledge-itself; personal development; socialization) which, it was argued, usually undercut the potential of each other. During periods of “crisis-talk” and throughout science educational history these three aims have repeatedly attempted to assert themselves. The inability of science education research to affect long-term change in classrooms was correlated not only to the failure to reach a consensus on the aims (due to competing programs and to the educational ideologies of their social groups), but especially to the failure of developing true educational theories (largely neglected since Hirst). Such theories, especially metatheories, could serve to reinforce science education’s growing sense of academic autonomy and independence from socio-economic demands. In Part II, I offer as a suggestion Egan’s cultural-linguistic theory as a metatheory to help resolve the impasse. I hope to make reformers familiar with his important ideas in general, and more specifically, to show how they can complement HPS rationales and reinforce the work of those researchers who have emphasized the value of narrative in learning science.

  2. Repeated-sprint ability - part II: recommendations for training.

    PubMed

    Bishop, David; Girard, Olivier; Mendez-Villanueva, Alberto

    2011-09-01

    Short-duration sprints, interspersed with brief recoveries, are common during most team sports. The ability to produce the best possible average sprint performance over a series of sprints (≤10 seconds), separated by short (≤60 seconds) recovery periods has been termed repeated-sprint ability (RSA). RSA is therefore an important fitness requirement of team-sport athletes, and it is important to better understand training strategies that can improve this fitness component. Surprisingly, however, there has been little research about the best training methods to improve RSA. In the absence of strong scientific evidence, two principal training theories have emerged. One is based on the concept of training specificity and maintains that the best way to train RSA is to perform repeated sprints. The second proposes that training interventions that target the main factors limiting RSA may be a more effective approach. The aim of this review (Part II) is to critically analyse training strategies to improve both RSA and the underlying factors responsible for fatigue during repeated sprints (see Part I of the preceding companion article). This review has highlighted that there is not one type of training that can be recommended to best improve RSA and all of the factors believed to be responsible for performance decrements during repeated-sprint tasks. This is not surprising, as RSA is a complex fitness component that depends on both metabolic (e.g. oxidative capacity, phosphocreatine recovery and H+ buffering) and neural factors (e.g. muscle activation and recruitment strategies) among others. While different training strategies can be used in order to improve each of these potential limiting factors, and in turn RSA, two key recommendations emerge from this review; it is important to include (i) some training to improve single-sprint performance (e.g. 'traditional' sprint training and strength/power training); and (ii) some high-intensity (80-90% maximal oxygen

  3. Simultaneous determination of trace Cd(II), Pb(II) and Cu(II) by differential pulse anodic stripping voltammetry using a reduced graphene oxide-chitosan/poly-l-lysine nanocomposite modified glassy carbon electrode.

    PubMed

    Guo, Zhuo; Li, Dong-di; Luo, Xian-Ke; Li, Ya-Hui; Zhao, Qi-Nai; Li, Meng-Meng; Zhao, Yang-Ting; Sun, Tian-Shuai; Ma, Chi

    2017-03-15

    The reduced graphene oxide (RGO) and Chitosan (CS) hybrid matrix RGO-CS were coated onto the glassy carbon electrode (GCE) surface, then, poly-l-lysine films (PLL) were prepared by electropolymerization with cyclic voltammetry (CV) method to prepare RGO-CS/PLL modified glassy carbon electrode (RGO-CS/PLL/GCE) for the simultaneous electrochemical determination of heavy metal ions Cd(II), Pb(II) and Cu(II). Combining the advantageous features of RGO and CS, RGO and CS are used together because the positively charged CS can interact with the negatively changed RGO to prevent their aggregation. Furthermore, CS has many amino groups along its macromolecular chains and possessed strongly reactive with metal ions. Moreover, PLL modified electrodes have good stability, excellent permselectivity, more active sites and strong adherence to electrode surface, which enhanced electrocatalytic activity. The RGO-CS/PLL/GCE was characterized voltammetrically using redox couples (Fe(CN)6(3-/4-)), complemented with electrochemical impedance spectroscopy (EIS). Differential pulse anodic stripping voltammetry (DPASV) has been used for the detection of Cd(II), Pb(II) and Cu(II). The detection limit of RGO-CS/PLL/GCE toward Cd(II), Pb(II) and Cu(II) is 0.01μgL(-1), 0.02μgL(-1) and 0.02μgL(-1), respectively. The electrochemical parameters that exert influence on deposition and stripping of metal ions, such as supporting electrolytes, pH value, deposition potential, and deposition time, were carefully studied.

  4. 40 CFR Appendix II to Part 1039 - Steady-State Duty Cycles

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... II to Part 1039 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Pt. 1039, App. II Appendix II to Part 1039—Steady-State Duty Cycles (a) The following duty cycles apply for...

  5. Recovery in soccer : part ii-recovery strategies.

    PubMed

    Nédélec, Mathieu; McCall, Alan; Carling, Chris; Legall, Franck; Berthoin, Serge; Dupont, Gregory

    2013-01-01

    In the formerly published part I of this two-part review, we examined fatigue after soccer matchplay and recovery kinetics of physical performance, and cognitive, subjective and biological markers. To reduce the magnitude of fatigue and to accelerate the time to fully recover after completion, several recovery strategies are now used in professional soccer teams. During congested fixture schedules, recovery strategies are highly required to alleviate post-match fatigue, and then to regain performance faster and reduce the risk of injury. Fatigue following competition is multifactorial and mainly related to dehydration, glycogen depletion, muscle damage and mental fatigue. Recovery strategies should consequently be targeted against the major causes of fatigue. Strategies reviewed in part II of this article were nutritional intake, cold water immersion, sleeping, active recovery, stretching, compression garments, massage and electrical stimulation. Some strategies such as hydration, diet and sleep are effective in their ability to counteract the fatigue mechanisms. Providing milk drinks to players at the end of competition and a meal containing high-glycaemic index carbohydrate and protein within the hour following the match are effective in replenishing substrate stores and optimizing muscle-damage repair. Sleep is an essential part of recovery management. Sleep disturbance after a match is common and can negatively impact on the recovery process. Cold water immersion is effective during acute periods of match congestion in order to regain performance levels faster and repress the acute inflammatory process. Scientific evidence for other strategies reviewed in their ability to accelerate the return to the initial level of performance is still lacking. These include active recovery, stretching, compression garments, massage and electrical stimulation. While this does not mean that these strategies do not aid the recovery process, the protocols implemented up until

  6. 40 CFR Appendix II to Part 600 - Sample Fuel Economy Calculations

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Sample Fuel Economy Calculations II Appendix II to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Pt. 600, App. II Appendix II...

  7. 40 CFR Appendix II to Part 600 - Sample Fuel Economy Calculations

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Sample Fuel Economy Calculations II Appendix II to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Pt. 600, App. II Appendix II...

  8. Synthesis and characterization of bis nitrato[4-hydroxyacetophenonesemicarbazone) nickel(II) complex as ionophore for thiocyanate-selective electrode.

    PubMed

    Chandra, Sulekh; Hooda, Sunita; Tomar, Praveen Kumar; Malik, Amrita; Kumar, Ankit; Malik, Sakshi; Gautam, Seema

    2016-05-01

    The PVC based-ion selective electrode viz., bis nitrato[4-hydroxyacetophenone semicarbazone] nickel(II) as an ionophore was prepared for the determination of thiocyanate ion. The ionophore was characterized by FT-IR, UV-vis, XRD, magnetic moment and elemental analysis (CHN). On the basis of spectral studies an octahedral geometry has been assigned. The best performance was obtained with a membrane composition of 31% PVC, 63% 2-nitrophenyl octylether, 4.0% ionophore and 2.0% trioctylmethyl ammonium chloride. The electrode exhibited an excellent Nernstian response to SCN(-) ion ranging from 1.0 × 10(-7) to 1.0 × 10(-1)M with a detection limit of 8.6 × 10(-8)M and a slope of -59.4 ± 0.2 mV/decade over a wide pH range (1.8-10.7) with a fast response time (6s) at 25 °C. The proposed electrode showed high selectivity for thiocyanate ion over a number of common inorganic and organic anions. It was successfully applied to direct determination of thiocyanate in biological (urine and saliva) samples in order to distinguish between smokers and non-smokers, environmental samples and as an indicator electrode for titration of thiocyanate ions with AgNO3 solution. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Part II--Management of pediatric post-traumatic headaches.

    PubMed

    Pinchefsky, Elana; Dubrovsky, Alexander Sasha; Friedman, Debbie; Shevell, Michael

    2015-03-01

    Post-traumatic headache is one of the most common symptoms occurring after mild traumatic brain injury in children. This is an expert opinion-based two-part review on pediatric post-traumatic headaches. In part II, we focus on the medical management of post-traumatic headaches. There are no randomized controlled trials evaluating the efficacy of therapies specifically for pediatric post-traumatic headaches. Thus, the algorithm we propose has been extrapolated from the primary headache literature and small noncontrolled trials of post-traumatic headache. Most post-traumatic headaches are migraine or tension type, and standard medications for these headache types are used. A multifaceted approach is needed to address all the possible causes of headache and any comorbid conditions that may delay recovery or alter treatment choices. For acute treatment, nonsteroidal anti-inflammatories can be used. If the headaches have migrainous features and nonsteroidal anti-inflammatories are not effective, triptans may be beneficial. Opioids are not indicated. Medication overuse should be avoided. For preventive treatments, some reports indicate that amitriptyline, gabapentin, or topiramate may be beneficial. Amitriptyline is a good choice because it can be used to treat both migraine and tension-type headaches. Nerve blocks, nutraceuticals (e.g. melatonin), and behavioral therapies may also be useful, and lifestyle factors, especially adequate sleep hygiene and strategies to cope with anxiety, should be emphasized. Improved treatment of acute post-traumatic headache may reduce the likelihood of developing chronic headaches, which can be especially problematic to effectively manage and can be functionally debilitating. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Thinking in nursing education. Part II. A teacher's experience.

    PubMed

    Ironside, P M

    1999-01-01

    Across academia, educators are investigating teaching strategies that facilitate students' abilities to think critically. Because may these strategies require low teacher-student ratios or sustained involvement over time, efforts to implement them are often constrained by diminishing resources for education, faculty reductions, and increasing number of part-time teachers and students. In nursing, the challenges of teaching and learning critical thinking are compounded by the demands of providing care to patients with increasingly acute and complex problems in a wide variety of settings. To meet these challenges, nurse teachers have commonly used a variety of strategies to teach critical thinking (1). For instance, they often provide students with case studies or simulated clinical situations in classroom and laboratory settings (2). At other times, students are taught a process of critical thinking and given structured clinical assignments, such as care plans or care maps, where they apply this process in anticipating the care a particular patient will require. Accompanying students onto clinical units, teachers typically evaluate critical thinking ability by reviewing a student's preparation prior to the experience and discussing it with the student during the course of the experience. The rationales students provide for particular nursing interventions are taken as evidence of their critical thinking ability. While this approach is commonly thought to be effective, the evolving health care system has placed increased emphasis on community nursing (3,4), where it is often difficult to prespecify learning experiences or to anticipate patient care needs. In addition, teachers are often not able to accompany each student to the clinical site. Thus, the traditional strategies for teaching and learning critical thinking common to hospital-based clinical courses are being challenged, transformed, and extended (5). Part II of this article describes findings that suggest

  11. Part 3: Pharmacogenetic Variability in Phase II Anticancer Drug Metabolism

    PubMed Central

    Deenen, Maarten J.; Cats, Annemieke; Beijnen, Jos H.

    2011-01-01

    Equivalent drug doses may lead to wide interpatient variability in drug response to anticancer therapy. Known determinants that may affect the pharmacological response to a drug are, among others, nongenetic factors, including age, gender, use of comedication, and liver and renal function. Nonetheless, these covariates do not explain all the observed interpatient variability. Differences in genetic constitution among patients have been identified to be important factors that contribute to differences in drug response. Because genetic polymorphism may affect the expression and activity of proteins encoded, it is a key covariate that is responsible for variability in drug metabolism, drug transport, and pharmacodynamic drug effects. We present a series of four reviews about pharmacogenetic variability. This third part in the series of reviews is focused on genetic variability in phase II drug-metabolizing enzymes (glutathione S-transferases, uridine diphosphoglucuronosyl transferases, methyltransferases, sulfotransferases, and N-acetyltransferases) and discusses the effects of genetic polymorphism within the genes encoding these enzymes on anticancer drug therapy outcome. Based on the literature reviewed, opportunities for patient-tailored anticancer therapy are proposed. PMID:21659608

  12. Stem cells in dentistry--Part II: Clinical applications.

    PubMed

    Egusa, Hiroshi; Sonoyama, Wataru; Nishimura, Masahiro; Atsuta, Ikiru; Akiyama, Kentaro

    2012-10-01

    New technologies that facilitate solid alveolar ridge augmentation are receiving considerable attention in the field of prosthodontics because of the growing requirement for esthetic and functional reconstruction by dental implant treatments. Recently, several studies have demonstrated potential advantages for stem-cell-based therapies in regenerative treatments. Mesenchymal stem/stromal cells (MSCs) are now an excellent candidate for tissue replacement therapies, and tissue engineering approaches and chair-side cellular grafting approaches using autologous MSCs represent the clinical state of the art for stem-cell-based alveolar bone regeneration. Basic studies have revealed that crosstalk between implanted donor cells and recipient immune cells plays a key role in determining clinical success that may involve the recently observed immunomodulatory properties of MSCs. Part II of this review first overviews progress in regenerative dentistry to consider the implications of the stem cell technology in dentistry and then highlights cutting-edge stem-cell-based alveolar bone regenerative therapies. Factors that affect stem-cell-based bone regeneration as related to the local immune response are then discussed. Additionally, pre-clinical stem cell studies for the regeneration of teeth and other oral organs as well as possible applications of MSC-based immunotherapy in dentistry are outlined. Finally, the marketing of stem cell technology in dental stem cell banks with a view toward future regenerative therapies is introduced. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Synthesis and Characterization of Organic-Inorganic Nanocomposite Poly-o-anisidine Sn(IV) Arsenophosphate: Its Analytical Applications as Pb(II) Ion-Selective Membrane Electrode

    PubMed Central

    Khan, Asif Ali; Habiba, Umme; Khan, Anish

    2009-01-01

    Poly-o-anisidine Sn(IV) arsenophosphate is a newly synthesized nanocomposite material and has been characterized on the basis of its chemical composition, ion exchange capacity, TGA-DTA, FTIR, X-RAY, SEM, and TEM studies. On the basis of distribution studies, the exchanger was found to be highly selective for lead that is an environmental pollutant. For the detection of lead in water a heterogeneous precipitate based ion-selective membrane electrode was developed by means of this composite cation exchanger as electroactive material. The membrane electrode is mechanically stable, with a quick response time, and can be operated over a wide pH range. The selectivity coefficients were determined by mixed solution method and revealed that the electrode is sensitive for Pb(II) in presence of interfering cations. The practical utility of this membrane electrode has been established by employing it as an indicator electrode in the potentiometric titration of Pb(II). PMID:20140082

  14. Disposable mercury-free cell-on-a-chip devices with integrated microfabricated electrodes for the determination of trace nickel(II) by adsorptive stripping voltammetry.

    PubMed

    Kokkinos, Christos; Economou, Anastasios; Raptis, Ioannis; Speliotis, Thanassis

    2008-08-01

    This work reports the fabrication of disposable three-electrode cells with integrated sputtered metal-film electrodes. The working electrode was a bismuth-film electrode (BiFE) while the reference and counter electrodes were made of Ag and Pt, respectively. The deposition of the metal layers was carried out by sputtering of the respective metals on a silicon substrate while the exact geometry of the electrodes was defined via a metal mask placed on the substrate during the deposition process. Initially, the electrodes were characterised by cyclic voltammetry. The utility of these devices was tested for the trace determination of Ni(II) by square wave adsorptive stripping voltammetry (SWAdSV) after complexation with dimethylglyoxime (DMG). The experimental variables (the presence of oxygen, the DMG concentration, the preconcentration potential, the accumulation time and the SW parameters), as well as potential interferences, were investigated. Using the selected conditions, the 3sigma limit of detection was 100 ng L(-1) for Ni(II) (for 90 s of preconcentration) and the relative standard deviation for Ni(II) was 2.3% at the 10 microg L(-1) level (n=8). Finally, the method was applied to the determination of Ni(II) in a certified river water sample.

  15. Electrochemical studies of some quinolone antibiotics. Part I. Qualitative analysis on mercury and carbon electrodes.

    PubMed

    Warowna-Grześkiewicz, M; Chodkowski, J; Fijałek, Z

    1995-01-01

    Direct current polarography and cyclic voltammetry was used to study quinolone antibiotics: ciprofloxacin, enoxacin, norfloxacin, ofloxacin and pefloxacin on a mercury and carbon electrode. The dependence of limiting currents and half-wave potentials on the pH of the solution, mercury head, temperature, ionic strength of the solution, methyl cellulose concentration, scan rate and quinolone concentration was studied. The optimal parameters and background solutions have been chosen. It was concluded that on mercury electrode quinolones are reduced in two one-electron waves and the process of the reduction is accompanied by an acid-base equilibrium. An anodic peak observed on graphite electrode is probably caused by the oxidation of piperazine ring in the molecule.

  16. IPCC Working Group II: Impacts and Adaptation Part I

    NASA Astrophysics Data System (ADS)

    Pulwarty, R. S.

    2007-12-01

    The IPCC (as opposed to the UN Framework Convention) defines climate change as" any change in climate over time, whether due to natural variability or as a result of human activity". The IPCC Working Group II (Impacts, Adaptation, Vulnerability) was charged with assessing the scientific, technical, environmental, economic, and social aspects of vulnerability to climate change, and, the negative and positive consequences for ecological systems, socio-economic sectors, and human health. The Working Group II report focused on the following issues for different sectors and regions (e.g. water, agriculture, biodiversity) and communities (coastal, island, etc.): · The role of adaptation in reducing vulnerability and impacts, · Assessment of adaptation capacity, options and constraints, and · Enhancing adaptation practice and operations. This presentation will address the following questions in the context of the results of the IPCC Fourth Assessment Report WG II: · What are the barriers, knowledge gaps, and opportunities for impacts assessments? · How are decisions about adaptation being made, and what types of adaptation strategies are being undertaken? · What are good adaptation practices and how are they learned over time? Examples will be drawn from the freshwater resources, small islands and adaptation chapters to which the presenter contributed. Many lessons have been identified but few have been implemented or evaluated over time. Adaptation occurs in the context of multiple stresses. Adaptation will be important in coping with early impacts in the near-term and continue to be important as our climate changes, regardless of how that change is derived. It is important to note that unmitigated climate change could, in the long term, exceed the capacity of different natural, managed and human systems to adapt. The assessment leads to the following conclusions: · Adaptation to climate change is already taking place, but on a limited basis · Adaptation measures

  17. Autism and EMF? Plausibility of a pathophysiological link part II.

    PubMed

    Herbert, Martha R; Sage, Cindy

    2013-06-01

    Autism spectrum conditions (ASCs) are defined behaviorally, but they also involve multileveled disturbances of underlying biology that find striking parallels in the physiological impacts of electromagnetic frequency and radiofrequency radiation exposures (EMF/RFR). Part I (Vol 776) of this paper reviewed the critical contributions pathophysiology may make to the etiology, pathogenesis and ongoing generation of behaviors currently defined as being core features of ASCs. We reviewed pathophysiological damage to core cellular processes that are associated both with ASCs and with biological effects of EMF/RFR exposures that contribute to chronically disrupted homeostasis. Many studies of people with ASCs have identified oxidative stress and evidence of free radical damage, cellular stress proteins, and deficiencies of antioxidants such as glutathione. Elevated intracellular calcium in ASCs may be due to genetics or may be downstream of inflammation or environmental exposures. Cell membrane lipids may be peroxidized, mitochondria may be dysfunctional, and various kinds of immune system disturbances are common. Brain oxidative stress and inflammation as well as measures consistent with blood-brain barrier and brain perfusion compromise have been documented. Part II of this paper documents how behaviors in ASCs may emerge from alterations of electrophysiological oscillatory synchronization, how EMF/RFR could contribute to these by de-tuning the organism, and policy implications of these vulnerabilities. It details evidence for mitochondrial dysfunction, immune system dysregulation, neuroinflammation and brain blood flow alterations, altered electrophysiology, disruption of electromagnetic signaling, synchrony, and sensory processing, de-tuning of the brain and organism, with autistic behaviors as emergent properties emanating from this pathophysiology. Changes in brain and autonomic nervous system electrophysiological function and sensory processing predominate, seizures

  18. The efficiency of electrocoagulation in treating wastewater from a dairy industry, part I: iron electrodes.

    PubMed

    Valente, Gerson Freitas Silva; Santos Mendonça, Regina Célia; Pereira, José Antonio Marques; Felix, Leonardo Bonato

    2012-01-01

    Iron electrodes were used for electrocoagulation (EC) treatment of wastewater from a dairy plant. Electrolysis time, pH, current density and distance between electrodes were considered to assess the removal efficiency of chemical oxygen demand (COD), total solids (TS) and their fractions and turbidity. Samples were collected from the effluent of a dairy plant using a sampling methodology proportional to the flow. The treatments were applied according to design factorial of half fraction with two levels of treatments and three repetitions at the central point. The optimization of parameters for treating dairy industry effluent by electrocoagulation using iron electrodes showed that electric current application for 15 minutes, an initial sample pH close to neutral (pH 7.0) and a current density of 50 A (.)(m-2) resulted in a significant reduction in COD by 58 %; removal of turbidity, suspended solids and volatile suspended solids by 95 %; and a final treated effluent pH of approximately 9.5. Negative consequences of the type of electrode used were the emergence of an undesirable color and an increase in the proportion of dissolved solids in the treated effluent.

  19. Part I: A comparative study of bismuth-modified screen-printed electrodes for lead detection.

    PubMed

    Quintana, Josefina Calvo; Arduini, Fabiana; Amine, Aziz; Punzo, Francesco; Destri, Giovanni Li; Bianchini, Chiara; Zane, Daniela; Curulli, Antonella; Palleschi, Giuseppe; Moscone, Danila

    2011-11-30

    Lead determination was carried out in the frame of the European Union project Biocop (www.biocop.org) using a bismuth-modified screen-printed electrode (Bi-SPE) and the stripping analysis technique. In order to choose a sensitive Bi-SPE for lead detection, an analytical comparative study of electrodes modified by Bi using "in situ", "ex situ" and "bulk" procedures was carried out. On the basis of the results obtained, we confirmed that the "in situ" procedure resulted in better analytical performances with respect to not only "ex situ" but also to "Bi(2)O(3) bulk" modified electrodes, allowing for a linear range of lead ion concentration from 0.5 to 100 μg L(-1) and a detection limit of 0.15 μg L(-1). We demonstrated that, before the Bi film deposition, an oxidative electrochemical pre-treatment of the working electrode could be useful because it eliminates traces of lead in the graphite-ink, as shown with stripping measurements. It also improves the electrochemical performance of the electrodes as demonstrated with Electrochemical Impedance Spectroscopy (EIS) measurements. The influence of different analytical parameters, such as the electrolyte solution composition (acetate buffer, chloridric acid, nitric acid, perchloric acid) and the ionic strength was investigated in order to evaluate how to treat the sample before the analysis. The morphology of prepared "in situ" Bi-SPEs was also characterized by Atomic Force Microscopy (AFM). Finally, the Bi-SPEs were used to determine the concentration of lead ions in tap and commercial water samples obtaining satisfactory values of the recovery percentage (81% and 98%).

  20. Cobalt(II)-selective membrane electrode based on a recently synthesized benzo-substituted macrocyclic diamide.

    PubMed

    Shamsipur, M; Poursaberi, T; Rouhani, S; Niknam, K; Sharghi, H; Ganjali, M R

    2001-09-01

    A PVC-membrane electrode based on a recently synthesized 18-membered macrocyclic diamide is presented. The electrode reveals a Nernstian potentiometric response for Co2+ over a wide concentration range (2.0 x 10(-6)-1.0 x 10(-2) M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities for Co2+ over a wide variety of other metal ions, and could be used over a wide pH range (3.0-8.0). The detection limit of the sensor is 6.0 x 10(-7) M. It was successfully applied to the direct determination and potentiometric titration of cobalt ion.

  1. Simultaneous trace-levels determination of Hg(II) and Pb(II) ions in various samples using a modified carbon paste electrode based on multi-walled carbon nanotubes and a new synthesized Schiff base.

    PubMed

    Afkhami, Abbas; Bagheri, Hasan; Khoshsafar, Hosein; Saber-Tehrani, Mohammad; Tabatabaee, Masoumeh; Shirzadmehr, Ali

    2012-10-09

    A modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) and 3-(4-methoxybenzylideneamino)-2-thioxothiazolodin-4-one as a new synthesized Schiff base was constructed for the simultaneous determination of trace amounts of Hg(II) and Pb(II) by square wave anodic stripping voltammetry. The modified electrode showed an excellent selectivity and stability for Hg(II) and Pb(II) determinations and for accelerated electron transfer between the electrode and the analytes. The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as pH, deposition potential and deposition time were optimized for the purpose of determination of traces of metal ions at pH 3.0. Under optimal conditions the limits of detection, based on three times the background noise, were 9.0×10(-4) and 6.0×10(-4) μmol L(-1) for Hg(II) and Pb(II) with a 90 s preconcentration, respectively. In addition, the modified electrode displayed a good reproducibility and selectivity, making it suitable for the simultaneous determination of Hg(II) and Pb(II) in real samples such as sea water, waste water, tobacco, marine and human teeth samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Discovery of Quantum structure and A Theory of Everything Part I and Part II

    NASA Astrophysics Data System (ADS)

    Zhang, Meggie

    2012-10-01

    (Part I) During my research I discovered logical errors in the logic of science and in mathematics. These errors caused scientists missed out important information when interpreting data. This led me to revisit the method of science and the existing results and able to find new information, which lead to the discovery of photon's structure. A ``particle collision illumination'' experiment then provided direct evidence supported the structure. Analysis of the properties of the structure suggested an organized but not-continuous multi-dimension (n-D) space within. Therefore I formed a hypothesis of a not-continuous n-D space structure. In search for evidence, I turned into crystal technology, and found direct evidence supported the hypotesis, then further particle collision found more evidence support this finding. (Part II) Analysis of single electron buildup revealed star and galaxy formation is from a single particle following a predictable pattern. This pattern is also common in matter formation. Analysis of the quantum structure suggested the formation of a larger structure through the space expansion within the structure. Further experiment results support the finding and result revealed the expansion is through space folding. Result also suggested a violation of energy conservation law that energy is created during the formation of matter, and matter itself is moving from a lower energy state to a higher energy state. When putting all information together, I arrived to a theory of everything which gives explanations to all existing phenomenon in the universe including black hole, dark energy, star formation, consciousness.

  3. NMG documentation. Part II. Programmer`s guide

    SciTech Connect

    Fritsch, F.N.; Dickinson, R.P. Jr.

    1996-07-01

    This is the 2nd of a 3-part report documenting NMG, the Numerical Mathematics Guide. This part is aimed at the programmer and contains Chapter 2, how it works. (Part I is aimed at the user of the system; Part III is aimed at the maintainer of NMG and will receive only limited distribution.)

  4. Carbon-modified electrode for ultra trace determination of Cd (II) in aqueous solution

    NASA Astrophysics Data System (ADS)

    Almustapha, Sakinatu; Khan, Aamir Amanat Ali; Omar, Abdul Aziz; Ariwahjoedi, Bambang; Abdullah, Mohd Azmuddin

    2014-10-01

    Increasing contamination of water by trace levels of heavy metals has become major environmental threats leading to an increased demand for the detection and monitoring of metal contaminants. In this work, modification of carbon electrode for Cd2+ detection using square wave anodic stripping voltammetry was reported. The deposition potential of -1.0 V in 0.1M acetate buffer for 240 sec, followed by square wave potential scan from -1.0 to -0.2 V were used. Stripping voltammogram showed current peaks corresponding to Cd2+. The sensitivity and selectivity of the modified electrodes for Cd2+ were also determined.

  5. Evaluation of commercial lithium-ion cells based on composite positive electrode for plug-in hybrid electric vehicle applications. Part I: Initial characterizations

    NASA Astrophysics Data System (ADS)

    Dubarry, Matthieu; Truchot, Cyril; Cugnet, Mikaël; Liaw, Bor Yann; Gering, Kevin; Sazhin, Sergiy; Jamison, David; Michelbacher, Christopher

    Evaluating commercial Li-ion batteries presents some unique benefits. One of them is to use cells made from established fabrication process and form factor, such as those offered by the 18650 cylindrical configuration, to provide a common platform to investigate and understand performance deficiency and aging mechanism of target chemistry. Such an approach shall afford us to derive relevant information without influence from processing or form factor variability that may skew our understanding on cell-level issues. A series of 1.9 Ah 18650 lithium ion cells developed by a commercial source using a composite positive electrode comprising {LiMn 1/3Ni 1/3Co 1/3O 2 + LiMn 2O 4} is being used as a platform for the investigation of certain key issues, particularly path-dependent aging and degradation in future plug-in hybrid electric vehicle (PHEV) applications, under the US Department of Energy's Applied Battery Research (ABR) program. Here we report in Part I the initial characterizations of the cell performance and Part II some aspects of cell degradation in 2C cycle aging. The initial characterizations, including cell-to-cell variability, are essential for life cycle performance characterization in the second part of the report when cell-aging phenomena are discussed. Due to the composite nature of the positive electrode, the features (or signature) derived from the incremental capacity (IC) of the cell appear rather complex. In this work, the method to index the observed IC peaks is discussed. Being able to index the IC signature in details is critical for analyzing and identifying degradation mechanism later in the cycle aging study.

  6. Evaluation of commercial lithium-ion cells based on composite positive electrode for plug-in hybrid electric vehicle applications. Part I: Initial characterizations

    SciTech Connect

    Matthieu Dubarry; Cyril Truchot; Mikael Cugnet; Bor Yann Liaw; Kevin Gering; Sergiy Sazhin; David Jamison; Christopher Michelbacher

    2011-12-01

    Evaluating commercial Li-ion batteries presents some unique benefits. One of them is to use cells made from established fabrication process and form factor, such as those offered by the 18650 cylindrical configuration, to provide a common platform to investigate and understand performance deficiency and aging mechanism of target chemistry. Such an approach shall afford us to derive relevant information without influence from processing or form factor variability that may skew our understanding on cell-level issues. A series of 1.9 Ah 18650 lithium ion cells developed by a commercial source using a composite positive electrode comprising (LiMn1/3Ni1/3Co1/3O2 + LiMn2O4) is being used as a platform for the investigation of certain key issues, particularly path-dependent aging and degradation in future plug-in hybrid electric vehicle (PHEV) applications, under the US Department of Energy's Applied Battery Research (ABR) program. Here we report in Part I the initial characterizations of the cell performance and Part II some aspects of cell degradation in 2C cycle aging. The initial characterizations, including cell-to-cell variability, are essential for life cycle performance characterization in the second part of the report when cell-aging phenomena are discussed. Due to the composite nature of the positive electrode, the features (or signature) derived from the incremental capacity (IC) of the cell appear rather complex. In this work, the method to index the observed IC peaks is discussed. Being able to index the IC signature in details is critical for analyzing and identifying degradation mechanism later in the cycle aging study.

  7. 40 CFR Appendix II to Part 600 - Sample Fuel Economy Calculations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Sample Fuel Economy Calculations II... FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Pt. 600, App. II Appendix II to Part 600—Sample Fuel Economy Calculations (a) This sample fuel economy calculation is applicable...

  8. 40 CFR Appendix II to Part 1068 - Emission-Related Parameters and Specifications

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Emission-Related Parameters and Specifications II Appendix II to Part 1068 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS GENERAL COMPLIANCE PROVISIONS FOR ENGINE PROGRAMS Pt. 1068, App. II Appendix...

  9. 40 CFR Appendix II to Part 600 - Sample Fuel Economy Calculations

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Sample Fuel Economy Calculations II... FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Pt. 600, App. II Appendix II to Part 600—Sample Fuel Economy Calculations (a) This sample fuel economy calculation is applicable...

  10. 40 CFR Appendix II to Part 600 - Sample Fuel Economy Calculations

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Sample Fuel Economy Calculations II... FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Pt. 600, App. II Appendix II to Part 600—Sample Fuel Economy Calculations (a) This sample fuel economy calculation is applicable...

  11. Topics in Chemical Instrumentation, Cl. Thermoluminescence: Part II. Instrumentation.

    ERIC Educational Resources Information Center

    Manche, Emanuel P.

    1979-01-01

    Presents part two on the use of the detection of thermoluminescence as an analytical tool for the chemistry laboratory and allied science. This part discusses instrumentation used and investigates recent developments in instrumentation for thermoluminescence. (HM)

  12. Topics in Chemical Instrumentation, Cl. Thermoluminescence: Part II. Instrumentation.

    ERIC Educational Resources Information Center

    Manche, Emanuel P.

    1979-01-01

    Presents part two on the use of the detection of thermoluminescence as an analytical tool for the chemistry laboratory and allied science. This part discusses instrumentation used and investigates recent developments in instrumentation for thermoluminescence. (HM)

  13. Electrochemical assay for the determination of nitric oxide metabolites using copper(II) chlorophyllin modified screen printed electrodes.

    PubMed

    Balamurugan, Murugesan; Madasamy, Thangamuthu; Pandiaraj, Manickam; Bhargava, Kalpana; Sethy, Niroj Kumar; Karunakaran, Chandran

    2015-06-01

    This work presents a novel electrochemical assay for the collective measurement of nitric oxide (NO) and its metabolites nitrite (NO2(-)) and nitrate (NO3(-)) in volume miniaturized sample at low cost using copper(II) chlorophyllin (CuCP) modified sensor electrode. Zinc oxide (ZnO) incorporated screen printed carbon electrode (SPCE) was used as a host matrix for the immobilization of CuCP. The morphological changes of the ZnO and CuCP modified electrodes were investigated using scanning electron microscopy. The electrochemical characterization of CuCP-ZnO-SPCE exhibited the characteristic quasi-reversible redox peaks at the potential +0.06 V versus Ag/AgCl. This biosensor electrode showed a wide linear range of response over NO concentrations from 200 nM to 500 μM with a detection limit of 100 nM and sensitivity of 85.4 nA μM(-1). Furthermore, NO2(-) measurement showed linearity of 100 nM to 1mM with a detection limit of 100 nM for NO2(-) and sensitivity of 96.4 nA μM(-1). Then, the concentration of NO3(-) was measured after its enzymatic conversion into NO2(-). Using this assay, the concentrations of NO, NO2(-), and NO3(-) present in human plasma samples before and after beetroot supplement were estimated using suitable membrane coated CuCP-ZnO-SPCE and validated with the standard Griess method.

  14. Coping With the Problems of a Technological Age, Part II.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Secondary Curriculum Development.

    This is another report in a series of programs dealing with the problems of a technological age. It is assumed that teachers will use both parts of this report. Part I deals with the problems of technology and how it affects our lives. It also discusses the energy crisis created, in part, by technology and deals specifically with coal and…

  15. Cadmium (II) and lead (II) transport in a polymer inclusion membrane using tributyl phosphate as mobile carrier and CuFeO(2) as a polarized photo electrode.

    PubMed

    Arous, Omar; Amara, Mourad; Trari, Mohamed; Bouguelia, Aissa; Kerdjoudj, Hacène

    2010-08-15

    In this work, a development of polymeric inclusion membranes for the cations separation is reported. The membrane was made up of cellulose triacetate (CTA) with a tributyl phosphate (TBP) incorporated into the polymer as metal ions carrier. The transport of lead (II) and cadmium (II) ions in two membrane systems polymer inclusion membrane (PIM), PIM coupled with photo-chemical electrode using TBP as carrier and 2-nitro phenyl octyl ether (NPOE) or tris ethylhexyl phosphate (TEHP) as plasticizer have been investigated. The membranes: polymer+plasticizer+carrier were synthesized and characterized by FTIR, X-ray diffraction and scanning electron microscopy (SEM). Transports of lead and cadmium have been studied using these systems and the results were compared to commercial cation exchange membrane (CRA). The obtained results showed that for Pb(2+) ion, the concentrations of the strip phase increases using synthesized membranes. The conduction band of the delafossite CuFeO(2) (-1.25 V(SCE)) yields a thermodynamically M(2+) (=Pb(2+), Cd(2+)) photo electrodeposition and speeds up the diffusion process. In all the cases, the potential of the electrode M/M(2+) in the feed compartment increases until a maximum value, reached at approximately 100 min above which it undergoes a diminution. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Determination of Pd(II) using an antimony film coated on a screen-printed electrode by adsorptive stripping voltammetry.

    PubMed

    Pérez-Ràfols, Clara; Trechera, Pedro; Serrano, Núria; Díaz-Cruz, José Manuel; Ariño, Cristina; Esteban, Miquel

    2017-05-15

    The use of an antimony film coated on a screen-printed carbon electrode (ex-situ SbSPCE) is proposed for the determination of Pd(II) at ppb levels in natural samples by adsorptive stripping voltammetry using dimethylglyoxime as chelating agent. Ex-situ SbSPCE produces a better analytical performance as compared to a commercially sputtered bismuth screen-printed electrode (BispSPE). The detection and quantification limits were 2.7 and 9.0µgL(-1) respectively with a good linear behaviour in the wide examined concentration range (from 1µgL(-1) up to 100.0µgL(-1), R(2)=0.998). The proposed ex-situ SbSPCE showed an excellent repeatability with a relative standard deviation of 0.5% for ten successive measurements and a very good reproducibility (1.6% for three different ex-situ SbSPCE units within series of ten repetitive assays). Moreover, the ex-situ SbSPCE was successfully applied for the determination of low concentration levels of Pd(II) in spiked tap water with a very high reproducibility (0.2%) and providing equivalent results to those achieved by ICP-MS measurements.

  17. Sporting Goods. Part I: Hunting and Fishing Equipment and Part II: Athletic, Marine, and Camping Equipment. A Distributive Education Manual.

    ERIC Educational Resources Information Center

    Day, Bill D., Comp.

    These manuals were prepared to introduce students to the fundamentals of hunting and fishing (Part I) and sports requiring athletic, marine and camping equipment (Part II). The sports salesman is in the position of offering a service to the customer, and he can best do so by understanding the sports and the variety of products which may be sold to…

  18. Determination of trace cobalt(II) by adsorptive stripping voltammetry on disposable microfabricated electrochemical cells with integrated planar metal-film electrodes.

    PubMed

    Kokkinos, Christos; Economou, Anastasios; Koupparis, Michael

    2009-01-15

    This work reports the determination of trace Co(II) by adsorptive stripping voltammetry on disposable three-electrode cells with on-chip metal-film electrodes. The heart of the sensors was a bismuth-film electrode (BiFE) with Ag and Pt planar strips serving as the reference and counter electrodes, respectively. Metals were deposited on a silicon chip by sputtering while the areas of the electrodes were patterned via a metal mask. Co(II) was determined by square wave adsorptive stripping voltammetry (SWAdSV) after complexation with dimethylglyoxime (DMG). The experimental variables (the DMG concentration, the preconcentration potential, the accumulation time and the SW parameters), as well as potential interferences, were investigated. Using the selected conditions, the 3 sigma limit of detection was 0.09 microg l(-1) of Co(II) (for 90s of preconcentration) and the relative standard deviation for Co(II) was 3.8% at the 2 microg l(-1) level (n=8). The method was applied to the determination of Co(II) in a certified river water sample. These mercury-free electrochemical devices present increased scope for field analysis and mu-TAS applications.

  19. Voltammetric analysis of ordnance materials. Part 2: A portable digital voltammeter for use with a silver wire working electrode

    NASA Astrophysics Data System (ADS)

    Fine, D. A.; Reeve, D. A.; Dickus, R. A.

    1984-12-01

    An inexpensive, portable, digital voltammeter has been designed and built at NWC. The instrument is intended for use with a silver wire working electrode. The voltammeter was built in response to a need on the part of Navy facilities for the monitoring of effluent water from the carbon column cleanup process used to remove propyleneglycoldinitrate from Otto fuel waste water. The instrument may also be used for the monitoring of contaminants such as nitroglycerin, dinitrotoluene, trinitrotoluene and nitroguanidine. This report describes in detail the construction, circuitry, software and operational features of the instrument.

  20. 10 CFR Appendix II to Part 1050 - DOE Form 3735.3-Foreign Travel Statement

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false DOE Form 3735.3-Foreign Travel Statement II Appendix II to.... II Appendix II to Part 1050—DOE Form 3735.3—Foreign Travel Statement EC01OC91.041 Statement Concerning Acceptance of Travel or Travel Expenses From a Foreign Government Item 1.This statement is to...

  1. 10 CFR Appendix II to Part 1050 - DOE Form 3735.3-Foreign Travel Statement

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false DOE Form 3735.3-Foreign Travel Statement II Appendix II to.... II Appendix II to Part 1050—DOE Form 3735.3—Foreign Travel Statement EC01OC91.041 Statement Concerning Acceptance of Travel or Travel Expenses From a Foreign Government Item 1.This statement is to...

  2. 10 CFR Appendix II to Part 1050 - DOE Form 3735.3-Foreign Travel Statement

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false DOE Form 3735.3-Foreign Travel Statement II Appendix II to.... II Appendix II to Part 1050—DOE Form 3735.3—Foreign Travel Statement EC01OC91.041 Statement Concerning Acceptance of Travel or Travel Expenses From a Foreign Government Item 1.This statement is to be...

  3. 10 CFR Appendix II to Part 1050 - DOE Form 3735.3-Foreign Travel Statement

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false DOE Form 3735.3-Foreign Travel Statement II Appendix II to.... II Appendix II to Part 1050—DOE Form 3735.3—Foreign Travel Statement EC01OC91.041 Statement Concerning Acceptance of Travel or Travel Expenses From a Foreign Government Item 1. This statement is to...

  4. 10 CFR Appendix II to Part 1050 - DOE Form 3735.3-Foreign Travel Statement

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false DOE Form 3735.3-Foreign Travel Statement II Appendix II to.... II Appendix II to Part 1050—DOE Form 3735.3—Foreign Travel Statement EC01OC91.041 Statement Concerning Acceptance of Travel or Travel Expenses From a Foreign Government Item 1.This statement is to...

  5. Solid-contact Hg(II)-selective electrode based on a carbon-epoxy composite containing a new dithiophosphate-based ionophore.

    PubMed

    Juarez-Gomez, J; Perez-Garcia, F; Ramirez-Silva, M T; Rojas-Hernandez, A; Galan-Vidal, C A; Paez-Hernandez, M E

    2013-09-30

    The experimental results herein concern a novel ion-selective electrode manufactured with an inner solid contact based on a new ligand O,O'-(2,2'-biphenylene)dithiophosphate pentyl (PenDTF). This electrode displays high selectivity toward the Hg(II) ion even in the presence of different divalent ions. The electrode also exhibited a good Nernstian response to Hg(II) (33.7±1.0 mV decade(-1)) over an ample concentration range (5.3×10(-7)-1.0×10(-2) mol L(-1)), with a detection limit of (6.1±1.7)×10(-7) mol L(-1). As a result of design, the electrode can be used for many experiments, simply renewing its contact surface with emery paper, without giving rise to a significant response deviation, exhibiting a variation coefficient of 3%, capable of being tested within the 0-5 pH interval. The electrode was used satisfactorily as indicating electrode during the potentiometric titration of Hg(II) ions with EDTA.

  6. A Conversation with William A. Fowler Part II

    NASA Astrophysics Data System (ADS)

    Greenberg, John

    2005-06-01

    Physicist William A.Fowler initiated an experimental program in nuclear astrophysics after World War II. He recalls here the Steady State versus Big Bang controversy and his celebrated collaboration with Fred Hoyle and Geoffrey and Margaret Burbidge on nucleosynthesis in stars. He also comments on the shift away from nuclear physics in universities to large accelerators and national laboratories.

  7. Layered manganese oxide intergrowth electrodes for rechargeable lithium batteries: Part 2. Substitution with Al

    SciTech Connect

    Patoux, Sebastien; Dolle, Mickael; Doeff, Marca M.

    2004-09-08

    The structural and electrochemical characterization of layered Li{sub x}Al{sub y}Mn{sub 1-y}O{sub 2} compounds prepared from sodium-containing precursors is described. A quaternary phase diagram showing composition ranges for pure P2 and P3 structures and P2/P3 intergrowths obtained in the Na-Al-Mn-O system is presented. Upon ion exchange, these compounds change to O2, O3 or O2/O3 stacking arrangements, respectively. The oxygen array in O3 and spinel structures is similar, and most of the O3 structures convert to spinel rapidly upon electrochemical cycling in lithium cells. This process is delayed somewhat by increased Al substitution, but not completely inhibited. More effective suppression of the phase transformation is observed in O2/O3 intergrowth electrodes. Additionally, the capacity retention upon cycling and the rate behavior of cells containing intergrowth electrodes is superior to those with pure O2 structures.

  8. Reforming Science Education: Part II. Utilizing Kieran Egan's Educational Metatheory

    ERIC Educational Resources Information Center

    Schulz, Roland M.

    2009-01-01

    This paper is the second of two parts and continues the conversation which had called for a shift in the conceptual focus of science education towards philosophy of education, with the requirement to develop a discipline-specific "philosophy" of science education. In Part I, conflicting conceptions of science literacy were identified with…

  9. Mathematics for Junior High School, Volume II (Part 1).

    ERIC Educational Resources Information Center

    Anderson, R. D.; And Others

    This is part one of a two-part SMSG mathematics text for junior high school students. Key ideas emphasized are structure of arithmetic from an algebraic viewpoint, the real number system as a progressing development, and metric and non-metric relations in geometry. Chapter topics include number line and coordinates, equations, scientific notation,…

  10. Mathematics for Junior High School, Volume II (Part 2).

    ERIC Educational Resources Information Center

    Anderson, R. D.; And Others

    This is part two of a two-part SMSG mathematics text for junior high school students. Key ideas emphasized are structure of arithmetic from an algebraic viewpoint, the real number system as a progressing development, and metric and non-metric relations in geometry. Chapter topics include real numbers, similar triangles, variation, non-metric…

  11. Asclepius, Caduceus, and Simurgh as medical symbols; part II. Simurgh.

    PubMed

    Nayernouri, Touraj

    2010-05-01

    In part one of this article I reviewed the history of Asclepius and the Caduceus of Hermes as medical symbols and made a tentative suggestion of using the mythical bird Simurgh as an Iranian symbol of medicine. In this, the second part, I shall describe the evolution of the myth of the Simurgh and discuss the medical relevance of this bird in Iranian history.

  12. Team effort: the nuclear medicine decision making process. Part II.

    PubMed

    Tsuchiyama, S

    1991-06-01

    This two part article examines the nuclear medicine purchase of Baptist Memorial Hospital in Memphis, the largest private hospital in the nation. Part I (May 1991) focused on what their needs were. This concluding installment looks at the committee mechanism itself and the reasoning that went behind their decisions.

  13. Electrochemical detection of Hg (II) ions using EDTA-PANI/SWNTs nanocomposite modified SS electrode

    NASA Astrophysics Data System (ADS)

    Deshmukh, M. A.; Patil, H. K.; Shirsat, M. D.; Ramanavicius, A.

    2017-05-01

    Detection of Hg (II) ions using EDTA modified polyaniline (PANI) and single walled carbon nanotubes (SWNTs) nanocomposite (PANI/SWNTs) was performed electrochemically via cyclic voltammetry (CV) technique. Dodecyl benzene sulphonic next step, PANI/SWNTs nanocomposite was modified acid sodium salt (DBSA) was used as a surfactant during this synthesis to get uniform suspension SWNTs. In the by EDTA solution containing crosslinking agent 1-ethyl-3(3-(dimethylamino) propyl) - carbodiimide (EDC) utilizing dip coating technique. The sensitivity of EDTA modified PANI/SWNTs nanocomposite towards Hg (II) ions was investigated. Differential pulse voltammetry (DPV) technique was applied for the electrochemical detection of Hg (II) ions.

  14. Classroom Demonstrations of Polymer Principles Part II. Polymer Formation.

    ERIC Educational Resources Information Center

    Rodriguez, F.; And Others

    1987-01-01

    This is part two in a series on classroom demonstrations of polymer principles. Described is how large molecules can be assembled from subunits (the process of polymerization). Examples chosen include both linear and branched or cross-linked molecules. (RH)

  15. Internal Auditing in Federal, State, and Local Governments (Part II).

    ERIC Educational Resources Information Center

    Knight, Susan; Wilson, Guy

    1981-01-01

    This second part of an annotated bibliography of reports, books, and journal articles concerned with internal auditing in government contexts reviews the available literature for an understanding of the types of internal audit, methods and practices, and other facets. (FM)

  16. Classroom Demonstrations of Polymer Principles Part II. Polymer Formation.

    ERIC Educational Resources Information Center

    Rodriguez, F.; And Others

    1987-01-01

    This is part two in a series on classroom demonstrations of polymer principles. Described is how large molecules can be assembled from subunits (the process of polymerization). Examples chosen include both linear and branched or cross-linked molecules. (RH)

  17. Designing SoTL Studies--Part II: Practicality

    ERIC Educational Resources Information Center

    Bartsch, Robert A.

    2013-01-01

    This chapter suggests solutions to common practical problems in designing SoTL studies. In addition, the advantages and disadvantages of different types of designs are discussed. [Part I available at EJ1029363.

  18. Predictors of performance on the National Board of Chiropractic Examiners Parts I and II*

    PubMed Central

    McCall, Angela R.; Harvey, Richard D.

    2014-01-01

    Objective The purpose of this study was to examine predictors for success on Parts I and II of the National Board of Chiropractic Examiners (NBCE) written examinations. Methods Two validity studies were conducted to examine the criterion validity of Logan College assessments for Part I and II NBCE scores. Both studies consisted of a longitudinal design to examine the validity of entrance grade point average (GPA), in-program chiropractic course content GPA, and an institutional practice exam on Parts I and II of the NBCE. Results Analyses revealed that Part I GPA and practice exam scores combined accounted for 72% of the variance within Part I NBCE scores. Furthermore, every subtest of the Part I NBCE could be reliably predicted by course performance. In the 2nd study, Part I GPA, Part I NBCE score, and Part II GPA accounted for 75% of the variance within Part II NBCE scores. Conclusions Internal training and educational assessments (eg, course grades and practice exams) proved to be strong determinants of NBCE performance above and beyond initial levels of preparedness, thus validating the impact of the chiropractic curriculum on NBCE test achievement. PMID:24611459

  19. Being prepared: bioterrorism and mass prophylaxis: part II.

    PubMed

    Weant, Kyle A; Bailey, Abby M; Fleishaker, Elise L; Justice, Stephanie B

    2014-01-01

    Although several biological agents have been recognized as presenting a significant threat to public health if used in a bioterrorist attack, those that are of greatest importance are known as the Category A agents: Bacillus anthracis (anthrax); variola major (smallpox); Yersinia pestis (plague); Francisella tularensis (tularemia); ribonucleic acid viruses (hemorrhagic fevers); and Clostridium botulinum (botulism toxin). In the previous issue, Part I of this review focused on the clinical presentation and treatment of anthrax, plague, and tularemia. In this second part of this 2-part review of these agents, the focus is on the clinical presentation and treatment of smallpox, viral hemorrhagic fevers, and botulism toxin. The utilization of mass prophylaxis to limit the morbidity and mortality associated with all these agents is also discussed along with the role emergency care personnel play in its implementation.

  20. Mental Retardation Grants; Part II, Research and Demonstration. Fiscal Year 1968.

    ERIC Educational Resources Information Center

    Department of Health, Education, and Welfare, Washington, DC. Secretary's Committee on Mental Retardation.

    Part II of a two-part publication listing mental retardation grants awarded by the U.S. Department of Health, Education, and Welfare in fiscal year 1968 (July 1, 1967, to June 30, 1968), the text includes grants awarded in the areas of research and demonstration. (Part I covers grants in training and construction.) Grants are arranged according to…

  1. Karst geomorphology: From hydrological functioning to palaeoenvironmental reconstructions. Part II

    NASA Astrophysics Data System (ADS)

    De Waele, Jo; Gutierrez, Francisco; Audra, Philippe

    2015-10-01

    In January 2015, the first part of the special issue on karst, entitled "Karst geomorphology: From hydrological functioning to palaeoenvironmental reconstructions" was published (Geomorphology, Vol. 229). This second part of the special issue comprises seven research papers covering a broad geographical canvas including Japan, Slovenia, France, Spain, Croatia, and Poland-Ukraine. Both issues mainly emanate from the contributions presented in the Karst session of the 8th International Conference of Geomorphology (International Association of Geomorphologists), held in Paris in August 2013, enriched with some invited papers.

  2. Operational strategies for dispatchable combined cycle plants, Part II

    SciTech Connect

    Nolan, J.P.; Landis, F.P.

    1996-11-01

    The Brush Cogeneration Facility is a dual-unit, combined cycle, cogeneration plant, operating in a dual cycling, automatically-dispatchable mode. Part I of this report described the contract, including automatic generation control (AGC) by Public Service Company of Colorado (PSCO), and the operation of Unit One. This part of the report covers the operation of Unit Two. Unit two is still in its operating infancy, but is showing that fuel efficiency and low emissions levels are not incompatible with cycling, load-following service. 1 fig.

  3. Managing risks in professional and clinical performance dilemmas: Part II.

    PubMed

    Schwab, N C; Pohlman, K J

    2000-08-01

    The primary purpose of the second article in this 2-part series is to describe and illustrate the use of an analytical framework that may assist school nurses to approach and resolve the dilemmas they may face in practice. Part I of the article was published in the April issue of this journal. It defined the terms "professional performance issue" and "clinical performance issue" and described a 5-step framework for analyzing practice dilemmas related to clinical and performance issues. In this article, the framework will be applied to a specific case scenario involving unsafe staffing and delegation.

  4. Biomedical research ethics: an Islamic view part II.

    PubMed

    Afifi, Raafat Y

    2007-12-01

    In part I of this article I discussed why Islam rejects secularization and this is not because the ethical principles embedded in Islam's teachings are archaic and out of touch with current realities. In addition, I pointed out the agreement between general broad principles of research ethics and Islamic teachings concerning life; which showed clearly that Islam has addressed the regulation of ethics in research more than 14 centuries ago. In this part, I will address two controversial issues concerning women's rights and age of consent for children as possible research subjects in a Muslim community.

  5. The Need for Ocean Literacy in the Classroom: Part II

    ERIC Educational Resources Information Center

    Schoedinger, Sarah; Cava, Francesca; Jewell, Beth

    2006-01-01

    As mentioned in Part I, certain classroom activities can help students learn about the ocean and empower them to make informed decisions about their impacts on the environment. One such activity focuses on harmful algal blooms (HABs). In this article, the authors include background information on HABs and then present two activities. Activity 1 is…

  6. Searching for the Right Way to Begin Class: Part II

    ERIC Educational Resources Information Center

    Lawry, John D.

    2012-01-01

    Part I, "Searching for the Right Way to Begin Class," described the various iterations of beginning class rituals the author used over the years. Those rituals began with a prayer to the Holy Spirit as was required at the Catholic women's college Marymount in Tarrytown, New York, where he first taught out of graduate school in 1965. That…

  7. Curriculum Guide for Hospitality Education. Part II. Exemplary Project.

    ERIC Educational Resources Information Center

    Kalani, Henry

    This second of a two-part study designed to develop a hospitality education program model for Hawaii's community colleges is based on the primary data gathered in a survey of the hospitality industry characteristics, manpower requirements, and employment demands. (Survey data is reported in volume 1 of the study.) The introductory section of this…

  8. Topics in Finance: Part II--Financial Analysis

    ERIC Educational Resources Information Center

    Laux, Judy

    2010-01-01

    The second article in a series designed to supplement the introductory financial management course, this essay addresses financial statement analysis, including its impact on stock valuation, disclosure, and managerial behavior. [For "Topics in Finance Part I--Introduction and Stockholder Wealth Maximization," see EJ1060345.

  9. Aesthetic Pursuits: Windows, Frames, Words, Images--Part II

    ERIC Educational Resources Information Center

    Burke, Ken

    2005-01-01

    In Part I of this study (Burke, 2005), the author presented the essentials of Image Presentation Theory--IPT--and its application to the analytical explication of various spatial designs in and psychological responses to images, from the illusions of depth in what is referred to as "windows" in cinema theory to the more patterned abstractions of…

  10. Observations on medical device design, Part II: Good practice.

    PubMed

    Alexander, K; Clarkson, J; Bishop, D

    1999-10-01

    Current guidance on design is inadequate. This second article in a two-part series presents a framework for good design practice that attempts to improve designers' awareness of manufacturing and validation issues. Seven design tactics, derived from observations of current industry practice and design literature, seek to encourage good practice and achieve safer, more profitable devices.

  11. DIY Soundcard Based Temperature Logging System. Part II: Applications

    ERIC Educational Resources Information Center

    Nunn, John

    2016-01-01

    This paper demonstrates some simple applications of how temperature logging systems may be used to monitor simple heat experiments, and how the data obtained can be analysed to get some additional insight into the physical processes. [For "DIY Soundcard Based Temperature Logging System. Part I: Design," see EJ1114124.

  12. Laboratory Animal Housing--Parts I and II.

    ERIC Educational Resources Information Center

    Runkle, Robert S.

    1963-01-01

    In recent years, the use of laboratory animals for bio-medical research has shown marked increase. Economic and efficient housing is a necessity. This two part report established guidelines for design and selection of materials for conventional animal housing. Contents include--(1) production and breeding facilities, (2) quarantine facilities, (3)…

  13. Report cards: Part II--Providers rating MCOs.

    PubMed

    Kaplan, J G

    1998-01-01

    Report cards on health plans and on physicians are becoming an increasingly important way of comparing health care quality from the perspective of consumers and the government. In the conclusion of a two-part article, the author suggests another side of the coin: physicians' own rating of health plans to guide their choices in health plan contracting.

  14. Surface anatomy and surface landmarks for thoracic surgery: Part II.

    PubMed

    Smith, Shona E; Darling, Gail E

    2011-05-01

    Surface anatomy is an integral part of a thoracic surgeon's armamentarium to assist with the diagnosis, staging, and treatment of thoracic pathology. As reviewed in this article, the surface landmarks of the lungs, heart, great vessels, and mediastinum are critical for appropriate patient care and should be learned in conjunction with classic anatomy. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Developing a Positive Self-Concept. Part II.

    ERIC Educational Resources Information Center

    Cibrowski, Lee; Slater, Shirley

    This publication supplements an earlier publication, "What Do You Like about Yourself? Developing a Positive Self-Concept" that presented an introduction to self-concept and included activities that could be used with students of all ages. This particular document, divided into two parts, includes additional ideas and activities that relate to…

  16. The Need for Ocean Literacy in the Classroom: Part II

    ERIC Educational Resources Information Center

    Schoedinger, Sarah; Cava, Francesca; Jewell, Beth

    2006-01-01

    As mentioned in Part I, certain classroom activities can help students learn about the ocean and empower them to make informed decisions about their impacts on the environment. One such activity focuses on harmful algal blooms (HABs). In this article, the authors include background information on HABs and then present two activities. Activity 1 is…

  17. Searching for the Right Way to Begin Class: Part II

    ERIC Educational Resources Information Center

    Lawry, John D.

    2012-01-01

    Part I, "Searching for the Right Way to Begin Class," described the various iterations of beginning class rituals the author used over the years. Those rituals began with a prayer to the Holy Spirit as was required at the Catholic women's college Marymount in Tarrytown, New York, where he first taught out of graduate school in 1965. That…

  18. Curriculum Guide for Hospitality Education. Part II. Exemplary Project.

    ERIC Educational Resources Information Center

    Kalani, Henry

    This second of a two-part study designed to develop a hospitality education program model for Hawaii's community colleges is based on the primary data gathered in a survey of the hospitality industry characteristics, manpower requirements, and employment demands. (Survey data is reported in volume 1 of the study.) The introductory section of this…

  19. Brief Internet and NREN Glossary: Part II (M-Z).

    ERIC Educational Resources Information Center

    Machovec, George S.

    1993-01-01

    Presents the second and final part of a selected glossary of terms commonly used in discussions relating to the Internet and the National Research and Education Network (NREN). Highlights include various network names; organizations; acronyms; user interfaces; network research testbeds; various protocols; remote login; and Wide Area Information…

  20. Solar Energy Education. Reader, Part II. Sun story. [Includes glossary

    SciTech Connect

    Not Available

    1981-05-01

    Magazine articles which focus on the subject of solar energy are presented. The booklet prepared is the second of a four part series of the Solar Energy Reader. Excerpts from the magazines include the history of solar energy, mythology and tales, and selected poetry on the sun. A glossary of energy related terms is included. (BCS)

  1. CONTEMPORARY ARABIC READERS--II. ARABIC ESSAYS, PART 1. TEXTS.

    ERIC Educational Resources Information Center

    MCCARUS, ERNEST N.; AND OTHERS

    INTENDED FOR INTERMEDIATE-LEVEL STUDENTS, "PART 1" OF THIS SECOND VOLUME IN THE "CONTEMPORARY ARABIC READERS" SERIES PRESENTS A COLLECTION OF 20 ESSAYS WRITTEN BY OUTSTANDING ARAB LITERARY FIGURES. SUBJECTS RANGE FROM POLITICAL AND RELIGIOUS PHILOSOPHY IN THE ARAB WORLD TO ECONOMIC DEVELOPMENT AND REFORMS IN AGRICULTURE AND THE WRITING SYSTEM. THE…

  2. CONTEMPORARY ARABIC READERS--II. ARABIC ESSAYS, PART 1. TEXTS.

    ERIC Educational Resources Information Center

    MCCARUS, ERNEST N.; AND OTHERS

    INTENDED FOR INTERMEDIATE-LEVEL STUDENTS, "PART 1" OF THIS SECOND VOLUME IN THE "CONTEMPORARY ARABIC READERS" SERIES PRESENTS A COLLECTION OF 20 ESSAYS WRITTEN BY OUTSTANDING ARAB LITERARY FIGURES. SUBJECTS RANGE FROM POLITICAL AND RELIGIOUS PHILOSOPHY IN THE ARAB WORLD TO ECONOMIC DEVELOPMENT AND REFORMS IN AGRICULTURE AND THE WRITING SYSTEM. THE…

  3. Finding Out about Archaeology: Parts I and II.

    ERIC Educational Resources Information Center

    Archaeological Inst. of America, Boston, MA.

    This packet of materials presents selected, descriptive bibliographies for children and young adults. Instructional materials for the use of teachers and parents are also included. Focusing on the subject of archaeology, part 1 of the annotated bibliography presents instructional materials coded for appropriate grade level use. Each entry…

  4. DIY Soundcard Based Temperature Logging System. Part II: Applications

    ERIC Educational Resources Information Center

    Nunn, John

    2016-01-01

    This paper demonstrates some simple applications of how temperature logging systems may be used to monitor simple heat experiments, and how the data obtained can be analysed to get some additional insight into the physical processes. [For "DIY Soundcard Based Temperature Logging System. Part I: Design," see EJ1114124.

  5. Diagnosis and local management of breast cancer: part II.

    PubMed

    Benson, John R

    2011-08-01

    This is the second of a two-part conference report and covers the other main themes of the Second Kyoto Breast Cancer Consensus Conference (KBCCC) including ductal carcinoma in situ, sentinel lymph node biopsy and therapeutic algorithms for local management of breast cancer. Once again, this report emphasizes conclusions from the consensus sessions that were a key feature of the KBCCC.

  6. Laboratory Animal Housing--Parts I and II.

    ERIC Educational Resources Information Center

    Runkle, Robert S.

    1963-01-01

    In recent years, the use of laboratory animals for bio-medical research has shown marked increase. Economic and efficient housing is a necessity. This two part report established guidelines for design and selection of materials for conventional animal housing. Contents include--(1) production and breeding facilities, (2) quarantine facilities, (3)…

  7. Aesthetic Pursuits: Windows, Frames, Words, Images--Part II

    ERIC Educational Resources Information Center

    Burke, Ken

    2005-01-01

    In Part I of this study (Burke, 2005), the author presented the essentials of Image Presentation Theory--IPT--and its application to the analytical explication of various spatial designs in and psychological responses to images, from the illusions of depth in what is referred to as "windows" in cinema theory to the more patterned abstractions of…

  8. Part I. Mechanisms of injury associated with extracorporeal shock wave lithotripsy; Part II. Exsolution of volatiles

    NASA Astrophysics Data System (ADS)

    Howard, Danny Dwayne

    Part I - Shock waves are focused in extracorporeal shock wave lithotripsy (ESWL) machines to strengths sufficient to fracture kidney stones. Substantial side effects-most of them acute-have resulted from this procedure, including injury to soft tissue. The focusing of shock waves through various layers of tissue is a complex process which stimulates many bio-mechano-chemical responses.This thesis presents results of an in vitro study of the initial mechanical stimulus. Planar nitrocellulose membranes of order 10 um thick were used as models of thin tissue structures. Two modes of failure were recorded: Failure due to cavitation collapsing on or near the membranes, and failure induced by altering the structure of shock waves. Tests were done in water at and around F2 to characterize the extent of cavitation damage, and was found to be confined within the focal region, 1.2 cm along the axis of focus.Scattering media were used to simulate the effects of acoustic nonuniformity of tissue and to alter the structure of focusing shock waves. 40 um diameter (average) hollow glass spheres were added to ethylene glycol, glycerine and castor oil to vary the properties of the scattering media. Multiple layer samples of various types of phantom tissue were tested in degassed castor oil to gauge the validity of the scattering media. The scattering media and tissue samples increased the rise time decreased strain rate in a similar fashion. Membranes were damaged by the decreased strain rate and accumulated effects of the altered structure: After about 20 or so shocks immersed in the scattering media and after about 100 shocks behind the tissue samples. The mode of failure was tearing with multiple tears in some cases from about .1 cm to about 3 cm depending of the number of shocks and membrane thickness.Part II - This work examines the exsolution of volatiles-carbon dioxide from water-in a cylindrical test cell under different pressure conditions. Water was supersaturated with

  9. Potentiometric detection of mercury(II) ions using a carbon paste electrode modified with substituted thiourea-functionalized highly ordered nanoporous silica.

    PubMed

    Javanbakht, Mehran; Divsar, Faten; Badiei, Alireza; Ganjali, Mohammad Reza; Norouzi, Parviz; Mohammadi Ziarani, Ghodsi; Chaloosi, Marzieh; Abdi Jahangir, Ali

    2009-06-01

    A potentiometric sensor is reported for the mercury(II) detection, which uses substituted thiourea-functionalized nanoporous silica (FTU-LUS-1) as the sensitive material. Substituted thiourea (FTU) and FTU-LUS-1 were first prepared and then characterized by 1H NMR, 19F NMR, 13C NMR, FTIR, XRD, TG and CNS elemental analysis. The electrodes with FTU-LUS-1 proportion of 10.0 wt% demonstrated very stable potentials. The prepared electrodes exhibit a Nernstian slope of 28.4 +/- 1.0 mV decade(-1) for mercury(II) ion over a wide concentration range of 1.0 x 10(-7) to 1.0 x 10(-1) mol dm(-3). The electrode exhibited a detection limit of 7.0 x 10(-8) mol dm(-3). Moreover, the selectivity coefficient, response time, performance, sensitivity and stability of the modified electrode were investigated. The electrode presented a response time of about 35 s, a high performance and sensitivity in a wide range of cation activities as well as good long term stability (more than 9 months). The method was satisfactory and could also be used to monitor the mercury(II) ion concentration in waste water and fish samples.

  10. Direct electrochemistry and bioelectrocatalysis of a class II non-symbiotic plant haemoglobin immobilised on screen-printed carbon electrodes.

    PubMed

    Chekin, Fereshteh; Leiva, Nélida; Raoof, Jahan Bakhsh; Gorton, Lo; Bülow, Leif

    2010-10-01

    In this study, direct electron transfer (ET) has been achieved between an immobilised non-symbiotic plant haemoglobin class II from Beta vulgaris (nsBvHb2) and three different screen-printed carbon electrodes based on graphite (SPCE), multi-walled carbon nanotubes (MWCNT-SPCE), and single-walled carbon nanotubes (SWCNT-SPCE) without the aid of any electron mediator. The nsBvHb2 modified electrodes were studied with cyclic voltammetry (CV) and also when placed in a wall-jet flow through cell for their electrocatalytic properties for reduction of H(2)O(2). The immobilised nsBvHb2 displayed a couple of stable and well-defined redox peaks with a formal potential (E°') of -33.5 mV (vs. Ag|AgCl|3 M KCl) at pH 7.4. The ET rate constant of nsBvHb2, k(s), was also determined at the surface of the three types of electrodes in phosphate buffer solution pH 7.4, and was found to be 0.50 s(-1) on SPCE, 2.78 s(-1) on MWCNT-SPCE and 4.06 s(-1) on SWCNT-SPCE, respectively. The average surface coverage of electrochemically active nsBvHb2 immobilised on the SPCEs, MWCNT-SPCEs and SWCNT-SPCEs obtained was 2.85 × 10(-10) mol cm(-2), 4.13 × 10(-10) mol cm(-2) and 5.20 × 10(-10) mol cm(-2). During the experiments the immobilised nsBvHb2 was stable and kept its electrochemical and catalytic activities. The nsBvHb2 modified electrodes also displayed an excellent response to the reduction of hydrogen peroxide (H(2)O(2)) with a linear detection range from 1 μM to 1000 μM on the surface of SPCEs, from 0.5 μM to 1000 μM on MWCNT-SPCEs, and from 0.1 μM to 1000 μM on SWCNT-SPCEs. The lower limit of detection was 0.8 μM, 0.4 μM and 0.1 μM at 3σ at the SPCEs, the MWCNT-SPCEs, and the SWCNT-SPCEs, respectively, and the apparent Michaelis-Menten constant, K(M)(app), for the H(2)O(2) sensors was estimated to be 0.32 mM , 0.29 mM and 0.27 mM, respectively.

  11. Sentinel lymph node biopsy and melanoma: 2010 update Part II.

    PubMed

    Stebbins, William G; Garibyan, Lilit; Sober, Arthur J

    2010-05-01

    This article will discuss the evidence for and against the therapeutic efficacy of early removal of potentially affected lymph nodes, morbidity associated with sentinel lymph node biopsy and completion lymphadenectomy, current guidelines regarding patient selection for sentinel lymph node biopsy, and the remaining questions that ongoing clinical trials are attempting to answer. The Sunbelt Melanoma Trial and the Multicenter Selective Lymphadenectomy Trials I and II will be discussed in detail. At the completion of this learning activity, participants should be able to discuss the data regarding early surgical removal of lymph nodes and its effect on the overall survival of melanoma patients, be able to discuss the potential benefits and morbidity associated with complete lymph node dissection, and to summarize the ongoing trials aimed at addressing the question of therapeutic value of early surgical treatment of regional lymph nodes that may contain micrometastases. Copyright 2010 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  12. GSTARS computer models and their applications, Part II: Applications

    USGS Publications Warehouse

    Simoes, F.J.M.; Yang, C.T.

    2008-01-01

    In part 1 of this two-paper series, a brief summary of the basic concepts and theories used in developing the Generalized Stream Tube model for Alluvial River Simulation (GSTARS) computer models was presented. Part 2 provides examples that illustrate some of the capabilities of the GSTARS models and how they can be applied to solve a wide range of river and reservoir sedimentation problems. Laboratory and field case studies are used and the examples show representative applications of the earlier and of the more recent versions of GSTARS. Some of the more recent capabilities implemented in GSTARS3, one of the latest versions of the series, are also discussed here with more detail. ?? 2008 International Research and Training Centre on Erosion and Sedimentation and the World Association for Sedimentation and Erosion Research.

  13. Wideband, low-frequency springless vibration energy harvesters: part II

    NASA Astrophysics Data System (ADS)

    Bendame, Mohamed; Abdel-Rahman, Eihab; Soliman, Mostafa

    2016-11-01

    This paper concludes a two-part investigation of a novel architecture for vibration energy harvesting (VEH), the springless VEH. In this part, we study vertical springless electromagnetic VEHs where the direction of motion is aligned with the gravitational field. Experimental results show the existence of three topologies in the response of vertical springless VEHs; linear, single-impact, and double-impact. A model, encompassing all three topologies, was developed and validated by comparison to experimental results. We found that vertical springless VEHs demonstrate low frequency harvesting (<20 Hz), widebeand harvesting (bandwidths up to \\text{BW}=11.2 Hz), and an optimal output power of P  =  7.52 mW at a base acceleration of 0.6 g. While horizontal springless VEHs typically offer more output power, the single-impact regime of the vertical springless VEHs offers the simultaneous advantages of wider harvesting bandwidths at lower operating frequencies.

  14. Achieving hemostasis in dermatology-Part II: Topical hemostatic agents.

    PubMed

    Glick, Jaimie B; Kaur, Ravneet R; Siegel, Daniel

    2013-07-01

    Bleeding is a common occurrence during any dermatologic surgery that disrupts blood vessels. The complications of excess bleeding can include delayed wound healing, hematoma formation, infection, dehiscence, and necrosis. In part one of this review, we discussed the pre-operative, intra-operative, and post-operative management of patients undergoing dermatologic surgery. In Part two, we discuss traditional and new topical hemostatic agents used to achieve hemostasis in dermatological procedures and surgery. We will evaluate the caustic and non-caustic hemostatic agents as well as hemostatic dressings. The mechanisms of action, side effect profile, and advantages and disadvantages of the topical hemostatic agents are provided. Sources for this article were found searching the English literature in PubMed for the time period 1940 to March 2012. A thorough bibliography search was also performed and key references examined.

  15. Comparison of microstickies measurement methods. Part II, Results and discussion

    Treesearch

    Mahendra R. Doshi; Angeles Blanco; Carlos Negro; Concepcion Monte; Gilles M. Dorris; Carlos C. Castro; Axel Hamann; R. Daniel Haynes; Carl Houtman; Karen Scallon; Hans-Joachim Putz; Hans Johansson; R. A. Venditti; K. Copeland; H.-M. Chang

    2003-01-01

    In part I of the article we discussed sample preparation procedure and described various methods used for the measurement of microstickies. Some of the important features of different methods are highlighted in Table 1. Temperatures used in the measurement methods vary from room temperature in some cases, 45 °C to 65 °C in other cases. Sample size ranges from as low as...

  16. Ada Integrated Environment II Computer Program Development Specification. Part 1.

    DTIC Science & Technology

    1981-12-01

    No. 6, Part 2, July-August 1978. 18. Rochkind, M. J., The Source Code Control System, IEEE Transactions on Software Engineering, SE-i, December 1975...TRACT (Continue an, reere side It noleearel and identfir &Y block number) The Ada Integrated Environment (AIE) consists of a set of software tools...intended to support design, development and maintenance of embedded computer software . A significant portion of an AIE includes software systems and

  17. Underwater Electromagnetic Sensor Networks, Part II: Localization and Network Simulations.

    PubMed

    Zazo, Javier; Macua, Sergio Valcarcel; Zazo, Santiago; Pérez, Marina; Pérez-Álvarez, Iván; Jiménez, Eugenio; Cardona, Laura; Brito, Joaquín Hernández; Quevedo, Eduardo

    2016-12-17

    In the first part of the paper, we modeled and characterized the underwater radio channel in shallowwaters. In the second part,we analyze the application requirements for an underwaterwireless sensor network (U-WSN) operating in the same environment and perform detailed simulations. We consider two localization applications, namely self-localization and navigation aid, and propose algorithms that work well under the specific constraints associated with U-WSN, namely low connectivity, low data rates and high packet loss probability. We propose an algorithm where the sensor nodes collaboratively estimate their unknown positions in the network using a low number of anchor nodes and distance measurements from the underwater channel. Once the network has been self-located, we consider a node estimating its position for underwater navigation communicating with neighboring nodes. We also propose a communication system and simulate the whole electromagnetic U-WSN in the Castalia simulator to evaluate the network performance, including propagation impairments (e.g., noise, interference), radio parameters (e.g., modulation scheme, bandwidth, transmit power), hardware limitations (e.g., clock drift, transmission buffer) and complete MAC and routing protocols. We also explain the changes that have to be done to Castalia in order to perform the simulations. In addition, we propose a parametric model of the communication channel that matches well with the results from the first part of this paper. Finally, we provide simulation results for some illustrative scenarios.

  18. Underwater Electromagnetic Sensor Networks, Part II: Localization and Network Simulations

    PubMed Central

    Zazo, Javier; Valcarcel Macua, Sergio; Zazo, Santiago; Pérez, Marina; Pérez-Álvarez, Iván; Jiménez, Eugenio; Cardona, Laura; Brito, Joaquín Hernández; Quevedo, Eduardo

    2016-01-01

    In the first part of the paper, we modeled and characterized the underwater radio channel in shallow waters. In the second part, we analyze the application requirements for an underwater wireless sensor network (U-WSN) operating in the same environment and perform detailed simulations. We consider two localization applications, namely self-localization and navigation aid, and propose algorithms that work well under the specific constraints associated with U-WSN, namely low connectivity, low data rates and high packet loss probability. We propose an algorithm where the sensor nodes collaboratively estimate their unknown positions in the network using a low number of anchor nodes and distance measurements from the underwater channel. Once the network has been self-located, we consider a node estimating its position for underwater navigation communicating with neighboring nodes. We also propose a communication system and simulate the whole electromagnetic U-WSN in the Castalia simulator to evaluate the network performance, including propagation impairments (e.g., noise, interference), radio parameters (e.g., modulation scheme, bandwidth, transmit power), hardware limitations (e.g., clock drift, transmission buffer) and complete MAC and routing protocols. We also explain the changes that have to be done to Castalia in order to perform the simulations. In addition, we propose a parametric model of the communication channel that matches well with the results from the first part of this paper. Finally, we provide simulation results for some illustrative scenarios. PMID:27999309

  19. Slag Behavior in Gasifiers. Part II: Constitutive Modeling of Slag

    SciTech Connect

    Massoudi, Mehrdad; Wang, Ping

    2013-02-07

    The viscosity of slag and the thermal conductivity of ash deposits are among two of the most important constitutive parameters that need to be studied. The accurate formulation or representations of the (transport) properties of coal present a special challenge of modeling efforts in computational fluid dynamics applications. Studies have indicated that slag viscosity must be within a certain range of temperatures for tapping and the membrane wall to be accessible, for example, between 1,300 °C and 1,500 °C, the viscosity is approximately 25 Pa·s. As the operating temperature decreases, the slag cools and solid crystals begin to form. Since slag behaves as a non-linear fluid, we discuss the constitutive modeling of slag and the important parameters that must be studied. We propose a new constitutive model, where the stress tensor not only has a yield stress part, but it also has a viscous part with a shear rate dependency of the viscosity, along with temperature and concentration dependency, while allowing for the possibility of the normal stress effects. In Part I, we reviewed, identify and discuss the key coal ash properties and the operating conditions impacting slag behavior.

  20. Fourier Transform Infrared Spectroscopy: Part II. Advantages of FT-IR.

    ERIC Educational Resources Information Center

    Perkins, W. D.

    1987-01-01

    This is Part II in a series on Fourier transform infrared spectroscopy (FT-IR). Described are various advantages of FT-IR spectroscopy including energy advantages, wavenumber accuracy, constant resolution, polarization effects, and stepping at grating changes. (RH)

  1. Fourier Transform Infrared Spectroscopy: Part II. Advantages of FT-IR.

    ERIC Educational Resources Information Center

    Perkins, W. D.

    1987-01-01

    This is Part II in a series on Fourier transform infrared spectroscopy (FT-IR). Described are various advantages of FT-IR spectroscopy including energy advantages, wavenumber accuracy, constant resolution, polarization effects, and stepping at grating changes. (RH)

  2. 40 CFR Appendix II to Part 1045 - Duty Cycles for Propulsion Marine Engines

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Duty Cycles for Propulsion Marine...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Pt. 1045, App. II Appendix II to Part 1045—Duty Cycles for Propulsion Marine Engines (a)...

  3. 40 CFR Appendix II to Part 1045 - Duty Cycles for Propulsion Marine Engines

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty Cycles for Propulsion Marine...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Pt. 1045, App. II Appendix II to Part 1045—Duty Cycles for Propulsion Marine Engines (a)...

  4. 40 CFR Appendix II to Part 1045 - Duty Cycles for Propulsion Marine Engines

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Duty Cycles for Propulsion Marine...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Pt. 1045, App. II Appendix II to Part 1045—Duty Cycles for Propulsion Marine Engines (a)...

  5. 40 CFR Appendix II to Part 1045 - Duty Cycles for Propulsion Marine Engines

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Duty Cycles for Propulsion Marine...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Pt. 1045, App. II Appendix II to Part 1045—Duty Cycles for Propulsion Marine Engines (a)...

  6. 31 CFR Appendix II to Part 13 - Form of Bill for Reimbursement

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Form of Bill for Reimbursement II Appendix II to Part 13 Money and Finance: Treasury Office of the Secretary of the Treasury PROCEDURES FOR... Accounting Office at such reasonable times and places as may be mutually agreed upon by said...

  7. 40 CFR Appendix II to Part 1045 - Duty Cycles for Propulsion Marine Engines

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Duty Cycles for Propulsion Marine...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Pt. 1045, App. II Appendix II to Part 1045—Duty Cycles for Propulsion Marine Engines (a)...

  8. 40 CFR Appendix II to Part 266 - Tier I Feed Rate Screening Limits for Total Chlorine

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Tier I Feed Rate Screening Limits for Total Chlorine II Appendix II to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Screening Limits for Total Chlorine Terrain-adjusted effective stack height (m) Noncomplex Terrain Urban...

  9. 40 CFR Appendix II to Part 266 - Tier I Feed Rate Screening Limits for Total Chlorine

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Tier I Feed Rate Screening Limits for Total Chlorine II Appendix II to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Screening Limits for Total Chlorine Terrain-adjusted effective stack height (m) Noncomplex Terrain Urban...

  10. 40 CFR Appendix II to Part 266 - Tier I Feed Rate Screening Limits for Total Chlorine

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Tier I Feed Rate Screening Limits for Total Chlorine II Appendix II to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Screening Limits for Total Chlorine Terrain-adjusted effective stack height (m) Noncomplex Terrain Urban...

  11. 40 CFR Appendix II to Part 266 - Tier I Feed Rate Screening Limits for Total Chlorine

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Tier I Feed Rate Screening Limits for Total Chlorine II Appendix II to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Screening Limits for Total Chlorine Terrain-adjusted effective stack height (m) Noncomplex Terrain Urban...

  12. 40 CFR Appendix II to Part 266 - Tier I Feed Rate Screening Limits for Total Chlorine

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Tier I Feed Rate Screening Limits for Total Chlorine II Appendix II to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Screening Limits for Total Chlorine Terrain-adjusted effective stack height (m) Noncomplex Terrain Urban...

  13. 46 CFR Appendix II to Part 150 - Explanation of Figure 1

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... COMPATIBILITY OF CARGOES Pt. 150, App. II Appendix II to Part 150—Explanation of Figure 1 Definition of a..., the inorganic acids. The cargo groups in the compatibility chart are separated into two categories: 1... certain Reactive Groups. Cargo Groups do not react hazardously with one another. Using the Compatibility...

  14. 46 CFR Appendix II to Part 150 - Explanation of Figure 1

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... COMPATIBILITY OF CARGOES Pt. 150, App. II Appendix II to Part 150—Explanation of Figure 1 Definition of a..., the inorganic acids. The cargo groups in the compatibility chart are separated into two categories: 1... certain Reactive Groups. Cargo Groups do not react hazardously with one another. Using the Compatibility...

  15. 46 CFR Appendix II to Part 150 - Explanation of Figure 1

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... COMPATIBILITY OF CARGOES Pt. 150, App. II Appendix II to Part 150—Explanation of Figure 1 Definition of a..., the inorganic acids. The cargo groups in the compatibility chart are separated into two categories: 1... certain Reactive Groups. Cargo Groups do not react hazardously with one another. Using the Compatibility...

  16. 46 CFR Appendix II to Part 150 - Explanation of Figure 1

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... COMPATIBILITY OF CARGOES Pt. 150, App. II Appendix II to Part 150—Explanation of Figure 1 Definition of a..., the inorganic acids. The cargo groups in the compatibility chart are separated into two categories: 1... certain Reactive Groups. Cargo Groups do not react hazardously with one another. Using the Compatibility...

  17. 40 CFR Appendix II to Part 1042 - Steady-State Duty Cycles

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Steady-State Duty Cycles II Appendix II to Part 1042 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Pt....

  18. 40 CFR Appendix II to Part 258 - List of Hazardous Inorganic and Organic Constituents

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true List of Hazardous Inorganic and Organic Constituents II Appendix II to Part 258 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... of Hazardous Inorganic and Organic Constituents Common name 1 CAS RN 2 Chemical abstracts...

  19. 40 CFR Appendix II to Part 258 - List of Hazardous Inorganic and Organic Constituents

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false List of Hazardous Inorganic and Organic Constituents II Appendix II to Part 258 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... 258—List of Hazardous Inorganic and Organic Constituents Common name 1 CAS RN 2 Chemical...

  20. 40 CFR Appendix II to Part 258 - List of Hazardous Inorganic and Organic Constituents

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false List of Hazardous Inorganic and Organic Constituents II Appendix II to Part 258 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... 258—List of Hazardous Inorganic and Organic Constituents Common name 1 CAS RN 2 Chemical...

  1. 40 CFR Appendix II to Part 258 - List of Hazardous Inorganic and Organic Constituents

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false List of Hazardous Inorganic and Organic Constituents II Appendix II to Part 258 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... 258—List of Hazardous Inorganic and Organic Constituents Common name 1 CAS RN 2 Chemical...

  2. 40 CFR Appendix II to Part 258 - List of Hazardous Inorganic and Organic Constituents

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false List of Hazardous Inorganic and Organic Constituents II Appendix II to Part 258 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... 258—List of Hazardous Inorganic and Organic Constituents Common name 1 CAS RN 2 Chemical...

  3. Electrochemical characterization of poly-beryllon II modified carbon paste electrode and its application to selective determination of pyrocatechol and hydroquinone.

    PubMed

    Zhou, Yuanzhen; Tang, Weimin; Dang, Fangfang; Chai, Shouning; Zhang, Liang

    2014-06-01

    A poly-beryllon II film modified carbon paste electrode (PBL-II/CPE) has been constructed by electropolymerization method. Electrochemical characterization of the PBL-II/CPE was investigated by electrochemical impedance spectroscopy (EIS). The electrochemical behaviors of pyrocatechol (PC) and hydroquinone (HQ) were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) at the PBL-II/CPE in pH 7.0 phosphate buffer solution (PBS). The anodic peak currents were dramatically enhanced about threefold for PC at PBL-II/CPE. In addition, the modified electrode exhibits good selectivity toward selective determination of PC and HQ. By using DPV method, low detection limits of 0.8μM for PC and 1.0μM for HQ were obtained, respectively. Many outstanding advantages, such as wide linear ranges, low detection limits, excellent sensitivity, selectivity and stability confirmed that the PBL-II/CPE has promising analytical performance. Meanwhile, the electrode was successfully used for the determination of PC and HQ in local tap water sample and the results are satisfactory.

  4. Covalent attachment of diphosphine ligands to glassy carbon electrodes via Cu-catalyzed alkyne-azide cycloaddition. Metallation with Ni( ii )

    SciTech Connect

    Das, Atanu K.; Engelhard, Mark H.; Lense, Sheri; Roberts, John A. S.; Bullock, R. Morris

    2015-01-01

    Covalent tethering of a P2N2ligand to a planar, azide-terminated glassy carbon electrode surface was accomplished using a CuI-catalyzed “click” reaction, followed by metallation with NiII.

  5. The museum maze in oral pathology demystifed: part II.

    PubMed

    Patil, Shankargouda; Rao, Roopa S; Ganavi, Bs

    2013-09-01

    Museum technology is perpetually changing due to current requirements and added inventions for our comfort and furbished display of specimens. Hence numerous methods of specimen preservation have been put on trial by diverse people in the medical feld as are the inventions. But only few have caught people's interest and are popularized today. This part provides unique insights into specialized custom-made techniques, evolution of recent advances like plastination and virtual museum that have popularized as visual delights. Plastination gives handy, perennial life-like acrylic specimens, whereas virtual museum takes museum feld to the electronic era making use of computers and virtual environment.

  6. Cancer Chemotherapy: Past, Present, and Future—Part II

    PubMed Central

    Wright, Jane C.

    1984-01-01

    Cancer is of major concern today because of its high mortality. It is estimated that 66 million people in this country will eventually develop cancer; 1983 estimates were 855,000 new cases and 440,000 deaths from cancer. Because of limitations of surgery and radiation therapy in effecting a cure for cancer, chemotherapy has become increasingly important. The developments in the chemical control of cancer in man are encouraging. This two-part paper* covers the historical milestones in the development of the chemical and hormonal control of cancer, present successes with the use of polychemotherapy, and the hopeful trend in research. PMID:6492179

  7. Responsive Persistence Part II. Practices of Postmodern Therapists.

    PubMed

    Sutherland, Olga; Dienhart, Anna; Turner, Jean

    2013-10-01

    This article, a companion to Part I of this series of articles, discusses how therapists informed by social constructionist and postmodern ideas enact persistence in their work with families. Transcripts and video-recordings of therapy interaction facilitated by selected major champions for three postmodern (collaborative) therapies: Michael White (narrative therapy), Harlene Anderson (collaborative language systems approach), and Bill O'Hanlon (solution-oriented therapy) were examined for persistence practices. The article offers a range of possible ways in which postmodern therapists may enact their influence in facilitating generative and helpful conversations with families and remain responsive to clients' preferences and understandings. Implications for family therapy practice, training, and supervision are discussed.

  8. Alkali cold gelation of whey proteins. Part II: Protein concentration.

    PubMed

    Mercadé-Prieto, Ruben; Gunasekaran, Sundaram

    2009-05-19

    The effect of the whey protein isolate (WPI) concentration on the sol-gel-sol transition in alkali cold gelation was investigated at pH 11.6-13 using oscillatory rheometry. The elastic modulus increases quickly with time to reach a local maximum (G'max), followed by a degelation step where the modulus decreases to a minimum value (G'min). Depending on the pH, a second gelation step will occur. At the end of the first gelation step around G'max, the system fulfilled the Winter-Chambon criterion of gelation. The analysis of the maximum moduli with the protein concentration shows that (i) there is a percolation concentration above which an elastic response is observed (approximately 6.8 wt %); (ii) there are two concentration regimes for G''max and G''max above this concentration, where we have considered power-law and percolation equations; (iii) there is a crossover concentration between the two regimes (at approximately 8 wt %) for both G'max and G''max when both moduli are equal, and this value is constant under all conditions tested (G'max=G''max approximately 4 Pa). Therefore, alkali cold gelation is better represented using two concentrations regimes than one, as observed for other biopolymers.

  9. Dynamic spreading of nanofluids on solids part II: modeling.

    PubMed

    Liu, Kuan-Liang; Kondiparty, Kirtiprakash; Nikolov, Alex D; Wasan, Darsh

    2012-11-27

    Recent studies on the spreading phenomena of liquid dispersions of nanoparticles (nanofluids) have revealed that the self-layering and two-dimensional structuring of nanoparticles in the three-phase contact region exert structural disjoining pressure, which drives the spreading of nanofluids by forming a continuous wedge film between the liquid (e.g., oil) and solid surface. Motivated by the practical applications of the phenomenon and experimental results reported in Part I of this two-part series, we thoroughly investigated the spreading dynamics of nanofluids against an oil drop on a solid surface. With the Laplace equation as a starting point, the spreading process is modeled by Navier-Stokes equations through the lubrication approach, which considers the structural disjoining pressure, gravity, and van der Waals force. The temporal interface profile and advancing inner contact line velocity of nanofluidic films are analyzed through varying the effective nanoparticle concentration, the outer contact angle, the effective nanoparticle size, and capillary pressure. It is found that a fast and spontaneous advance of the inner contact line movement can be obtained by increasing the nanoparticle concentration, decreasing the nanoparticle size, and/or decreasing the interfacial tension. Once the nanofluidic film is formed, the advancing inner contact line movement reaches a constant velocity, which is independent of the outer contact angle if the interfacial tension is held constant.

  10. Histologic features of alopecias: part II: scarring alopecias.

    PubMed

    Bernárdez, C; Molina-Ruiz, A M; Requena, L

    2015-05-01

    The diagnosis of disorders of the hair and scalp can generally be made on clinical grounds, but clinical signs are not always diagnostic and in some cases more invasive techniques, such as a biopsy, may be necessary. This 2-part article is a detailed review of the histologic features of the main types of alopecia based on the traditional classification of these disorders into 2 major groups: scarring and nonscarring alopecias. Scarring alopecias are disorders in which the hair follicle is replaced by fibrous scar tissue, a process that leads to permanent hair loss. In nonscarring alopecias, the follicles are preserved and hair growth can resume when the cause of the problem is eliminated. In the second part of this review, we describe the histologic features of the main forms of scarring alopecia. Since a close clinical-pathological correlation is essential for making a correct histopathologic diagnosis of alopecia, we also include a brief description of the clinical features of the principal forms of this disorder.

  11. Active flow control for a NACA-0012 Profile: Part II

    NASA Astrophysics Data System (ADS)

    Oualli, H.; Makadem, M.; Ouchene, H.; Ferfouri, A.; Bouabdallah, A.; Gad-El-Hak, M.

    2016-11-01

    Active flow control is applied to a NACA-0012 profile. The experiments are conducted in a wind tunnel. Using a high-resolution visible-light camera and tomography, flow visualizations are carried out. LES finite-volume 3D code is used to complement the physical experiments. The symmetric wing is clipped into two parts, and those parts extend and retract along the chord according to the same sinusoidal law we optimized last year for the same profile but clipped at an angle of 60 deg, instead of the original 90 deg. The Reynolds number range is extended to 500,000, thus covering the flying regimes of micro-UAVs, UAVs, as well as small aircraft. When the nascent cavity is open and the attack angle is 30 deg, the drag coefficient is increased by 1,300%, as compared to the uncontrolled case. However, when the cavity is covered and Re <=105 , a relatively small frequency, f <= 30 Hz, is required for the drag coefficient to drop to negative values. At the maximum Reynolds number, thrust is generated but only at much higher frequencies, 12 <= f <= 16 kHz.

  12. Collagenolytic (necrobiotic) granulomas: part II--the 'red' granulomas.

    PubMed

    Lynch, Jane M; Barrett, Terry L

    2004-07-01

    A collagenolytic or necrobiotic non-infectious granuloma is one in which a granulomatous infiltrate develops around a central area of altered collagen and elastic fibers. The altered fibers lose their distinct boundaries and exhibit new staining patterns, becoming either more basophilic or eosinophilic. Within the area of altered collagen, there may be deposition of acellular substances such as mucin (blue) or fibrin (red), or there may be neutrophils with nuclear dust (blue), eosinophils (red), or flame figures (red). These color distinctions can be used as a simple algorithm for the diagnosis of collagenolytic granulomas, i.e. 'blue' granulomas vs. 'red' granulomas. Eight diagnoses are included within these two groupings, which are discussed in this two-part article. In the previously published first part, the clinical presentation, pathogenesis and histologic features of the 'blue' collagenolytic granulomas were discussed. These are the lesions of granuloma annulare, Wegener's granulomatosis, and rheumatoid vasculitis. In this second half of the series, the 'red' collagenolytic granulomas are discussed; these are the lesions of necrobiosis lipoidica, necrobiotic xanthogranuloma, rheumatoid nodules, Churg-Strauss syndrome, and eosinophilic cellulitis (Well's Syndrome).

  13. Solar System: Surfing the Edge of Chaos Part II

    NASA Astrophysics Data System (ADS)

    Hayes, Wayne B.; Danforth, C. M.

    2008-05-01

    The orbital positions and masses of the Jovian planets are known only to a few parts in 107. At the 2006 DDA meeting in Halifax, I presented results, recently published in Nature Physics and MNRAS, which demonstrated the existence of both chaotic and near-regular orbits within the current observational error volume. In this talk, joint work with Chris Danforth of the University of Vermont, we present results demonstrating extremely rich structure of Lyapunov times within the uncertainty volume across many two-dimensional slices through initial-condition space. These slices include the Cartesian product of every pair of orbital semi-major axes ap, plus Cartesian products between ap and eccentricity ep for each Jovian planet p. Some of the observed structure is reminiscent of Guzzo's "Web of 3-body resonances", although it is not clear that 3-body resonances are the cause in this case since the structure extends several orders of magnitude below the scale at which Murray + Holman's 3-body resonance theory has been explored. Some of the structure is entirely unlike that seen in Guzzo's Web, and may require further theoretical development to understand. Finally, several "zoom-in” plots, reminiscent of those done for the Mandelbrot set, demonstrate that the structure continues down, at least, to scales of about one part in 109. In all cases, we verify the reliability of our integrations using convergence tests to demonstrate that the picture does not change even when the integration timestep is decreased significantly.

  14. Nanoparticles and the blood coagulation system. Part II: safety concerns.

    PubMed

    Ilinskaya, Anna N; Dobrovolskaia, Marina A

    2013-06-01

    Nanoparticle interactions with the blood coagulation system can be beneficial or adverse depending on the intended use of a nanomaterial. Nanoparticles can be engineered to be procoagulant or to carry coagulation-initiating factors to treat certain disorders. Likewise, they can be designed to be anticoagulant or to carry anticoagulant drugs to intervene in other pathological conditions in which coagulation is a concern. An overview of the coagulation system was given and a discussion of a desirable interface between this system and engineered nanomaterials was assessed in part I, which was published in the May 2013 issue of Nanomedicine. Unwanted pro- and anti-coagulant properties of nanoparticles represent significant concerns in the field of nanomedicine, and often hamper the development and transition into the clinic of many promising engineered nanocarriers. This part will focus on the undesirable effects of engineered nanomaterials on the blood coagulation system. We will discuss the relationship between the physicochemical properties of nanoparticles (e.g., size, charge and hydrophobicity) that determine their negative effects on the blood coagulation system in order to understand how manipulation of these properties can help to overcome unwanted side effects.

  15. Nanoparticles and the blood coagulation system. Part II: safety concerns

    PubMed Central

    Ilinskaya, Anna N; Dobrovolskaia, Marina A

    2014-01-01

    Nanoparticle interactions with the blood coagulation system can be beneficial or adverse depending on the intended use of a nanomaterial. Nanoparticles can be engineered to be procoagulant or to carry coagulation-initiating factors to treat certain disorders. Likewise, they can be designed to be anticoagulant or to carry anticoagulant drugs to intervene in other pathological conditions in which coagulation is a concern. An overview of the coagulation system was given and a discussion of a desirable interface between this system and engineered nanomaterials was assessed in part I, which was published in the May 2013 issue of Nanomedicine. Unwanted pro- and anti-coagulant properties of nanoparticles represent significant concerns in the field of nanomedicine, and often hamper the development and transition into the clinic of many promising engineered nanocarriers. This part will focus on the undesirable effects of engineered nanomaterials on the blood coagulation system. We will discuss the relationship between the physicochemical properties of nanoparticles (e.g., size, charge and hydrophobicity) that determine their negative effects on the blood coagulation system in order to understand how manipulation of these properties can help to overcome unwanted side effects. PMID:23730696

  16. The year's new drugs & biologics 2014 - Part II: trends & challenges.

    PubMed

    Graul, A I; Serebrov, M; Cruces, E; Tracy, M; Dulsat, C

    2015-02-01

    2014 was a year of continued high activity in the pharma and biotech industry, as evidenced in part I of this annual two-part review article published last month in this journal (1). As of December 23, 2014, a total of 55 new chemical and biological entities had reached their first markets worldwide, together with another 29 important new line extensions. Another 19 products were approved for the first time during the year but not yet launched by December 23. Furthermore, during the now-traditional year-end sprint, several regulatory agencies issued last-minute approvals for other compounds that missed the deadline for inclusion in that article, bringing the total of new approvals for the year to a somewhat higher number. In addition to the successful development, registration and launch of new drugs and biologics, there are various other trends and tendencies that serve as indicators of the overall health and status of the industry. These include the pursuit of novel programs designed by regulators to stimulate the development of drugs for diseases that are currently under-treated; the regular and pragmatic culling by companies of their R&D pipelines; and the decision to unify pipelines, portfolios and sales forces through mergers and acquisitions.

  17. Underpotential deposition of tin(II) on a gold disc electrode and determination of tin in a tin plate sample.

    PubMed

    Qiao, Zhiqing; Shang, Wei; Zhang, Xin; Wang, Chunming

    2005-04-01

    This work describes a study of the underpotential deposition (UPD) of Sn2+ on a polycrystalline gold disc electrode using cyclic voltammetry (CV) and chronocoulometry (CC). Sn2+ ions showed well-defined peaks from UPD and UPD stripping (UPD-S) in 1 mol/L HCl solutions, while bulk deposition (BD) and BD stripping (BD-S) of the ions were also observed. The measured UPD shifts, DeltaE(UPD), between the UPD-S and the BD-S peaks were more than 200 mV. The UPD charge and the surface coverage of tin were measured by CC. A new method for determining Sn2+ was therefore developed, based on the excellent electrochemical properties of the Au/Sn UPD system. A plot of the UPD-DPASV (differential pulse anodic stripping voltammetry) signal versus the Sn(II) concentration was obtained for [Sn(II)] of 1.98x10(-7) to 3.64x10(-5) M. The method developed here has been applied to determine the tin in a tin plate sample.

  18. Modified sprint interval training protocols. Part II. Psychological responses.

    PubMed

    Townsend, Logan K; Islam, Hashim; Dunn, Emily; Eys, Mark; Robertson-Wilson, Jennifer; Hazell, Tom J

    2017-04-01

    Sprint-interval training (SIT) is a viable method to improve health and fitness. However, researchers have questioned the utility of SIT because of its strenuous nature. The current study aimed to determine if manipulating the sprint and recovery duration, while maintaining the 1:8 work to rest ratio, could uncover a more favourable SIT protocol. Nine healthy active males (age, 23.3 ± 3.0 years; body mass index, 22.4 ± 2.2 kg·m(-2); maximal oxygen consumption, 48.9 ± 5.3 mL·kg(-1)·min(-1)) participated in 3 experimental running SIT sessions: (i) 30:240 (4 × 30-s efforts, 240-s recovery), (ii) 15:120 (8 × 15-s efforts, 120-s recovery), (iii) 5:40 (24 × 5-s efforts, 40-s recovery), and (iv) a final behavioural choice follow-up session. Affect, intentions, task self-efficacy, enjoyment, and preference were evaluated. Midway through exercise, affect became more positive for 5:40 compared with 30:240 (p < 0.05) and postexercise affect was greater for both 5:40 (p = 0.014) and 15:120 (p = 0.015) compared with 30:240. Participants expressed greater intentions to perform 5:40 3 and 5 times/week compared with 15:120 and 30:240 (p < 0.05). Participants felt more confident in their ability to perform 5:40 (p = 0.001) and 15:120 (p = 0.008) compared with 30:240. The 5:40 session was also rated as more enjoyable than 15:120 (p = 0.025) and 30:240 (p = 0.026). All participants preferred the 5:40 protocol. These data suggest that shorter sprints with more repetitions are perceived as more enjoyable and lead to greater intentions to engage in SIT.

  19. Planar LTCC transformers for high voltage flyback converters: Part II.

    SciTech Connect

    Schofield, Daryl; Schare, Joshua M., Ph.D.; Slama, George; Abel, David

    2009-02-01

    This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

  20. Indoor Air Quality: part II--what it does.

    PubMed

    Pike-Paris, Ann

    2005-01-01

    Newton, MA. A recent report indicated air quality samples taken from several rooms in the town's North High School had elevated CO2 levels of 2,000 parts per million (ppm) (Viser, 2004). State standards set 800 ppm as the optimum reading. Although not an immediate health issue, high CO2 levels are indicative of poor air circulation--clean air comes in but stale air is not vented out. Safety issues arise in the school setting when chemicals or toxic substances are in use and cannot be vented, therefore posing the health risk (Viser, 2004). Poor Indoor Air Quality (IAQ) in schools can result in decreased academic performance and days lost due to illness in the school age population (Environmental Protection Agency [EPA], 2003). As the school nurse at North High School, what would you do?

  1. Theory of edge radiation. Part II: Advanced applications

    NASA Astrophysics Data System (ADS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni; Schneidmiller, Evgeni; Yurkov, Mikhail

    2009-08-01

    In this paper we exploit a formalism to describe edge radiation, which relies on Fourier optics techniques [G. Geloni, V. Kocharyan, E. Saldin, E. Schneidmiller, M. Yurkov, Theory of edge radiation. Part I: foundations and basic applications, submitted for publication]. First, we apply our method to develop an analytical model to describe edge radiation in the presence of a vacuum chamber. Such model is based on the solution of the field equation with a tensor Green's function technique. In particular, explicit calculations for a circular vacuum chamber are reported. Second, we consider the use of edge radiation as a tool for electron-beam diagnostics. We discuss coherent edge radiation, extraction of edge radiation by a mirror, and other issues becoming important at high electron energy and long radiation wavelength. Based on this work we also study the impact of edge radiation on X-ray Free-Electron Laser (XFEL) setups and we discuss recent results.

  2. Solar box-cooker: Part II-analysis and simulation

    SciTech Connect

    Thulasi Das, T.C. ); Karmakar, S. ); Rao, D.P. )

    1994-03-01

    Based on the model proposed in the companion paper (Part I), a method is outlined simulation of the solar box-cookers loaded with one, two, or four vessels. The relative importance of various heat-exchange rates in the cooker were examined. The effect of parameters such as the thickness and size of the absorber plate, emissivity of the vessel, insulation thickness, and cooking time were studied. Cookers of three sizes were simulated to assess their adequacy in cooking. The studies indicate that the black paint on the vessels could be avoided if weathered stainless steel or aluminum vessels are used. The cooker with inner dimensions of 0.6 x 0.6 x 0.1 m[sup 3] was found to be adequate to cook lunch and dinner on a clear day even in the winter months. Experimental studies carried out to obtain the heat-transfer coefficients, required for simulation, are presented.

  3. Cervical spondylotic myelopathy: Part II: clinical and imaging considerations *

    PubMed Central

    Burns, SH; O’Connor, SM; Mior, SA

    1991-01-01

    In this, the second of a two part series, we continue to review the recent literature pertaining to cervical spondylotic myelopathy (CSM). Caused by the compromise of the spinal canal resulting from the superimposition of spondylotic changes upon a congenitally narrowed canal, CSM has a predictable radiographic and clinical presentation. The clinical presentation frequently includes both upper and lower motor neuron signs and symptoms. Careful analysis of the plain film images usually reveals a spinal canal measuring 12 mm or less. Additional imaging modalities confirm the diagnosis. This paper presents the clinical and imaging characteristics underlying CSM and stresses the importance of including CSM in the differential diagnosis of patients complaining of neck and leg dysfunctions. ImagesFigure 1Figure 2Figure 3Figure 4

  4. Nonequilibrium fluctuation theory in electrochemical nucleation. II. Experimental determination of critical fluctuation in silver nucleation onto platinum electrode

    NASA Astrophysics Data System (ADS)

    Tadano, Atsushi; Aogaki, Ryoichi

    1997-04-01

    Following part I, in this paper, the experiments for silver nucleation onto platinum electrode in AgNO3+NaNO3 solution were carried out to compare the theoretical equations with experimental data. The theoretical examination predicted that after double layer charging current a minimum current emerges, accompanied with rapid monolayer nucleus formation. Since the monolayer nuclei prepare the substrates for the following extensive nucleation, the stage when the nuclei are formed is of much importance. From the experiments for double layer charging current, it was decided that the nucleus formation is activated at the final stage of the charging. This result reinforces the theoretical prediction that the monolayer nuclei are formed by the minimum current. Extrapolation of the minimum current to the critical state gave the critical autocorrelation distance and the average critical concentration fluctuation on the completely active surface. The autocorrelation distance was determined as ãcr=7.82×10-4 m at 300 K, which is quite large in comparison with the scale of the fluctuation and in good agreement with the value obtained in nickel pitting dissolution. On the other hand, as discussed in the previous paper, since there is no intense specific adsorption of ions onto the electrode surface, the electrostatic interaction between the ions accelerates the simultaneous adsorption of Ag+ ion and NO3- ion. Therefore, it was concluded that the concentration of the supporting electrolyte NaNO3 also fluctuates with the Ag+ ionic concentration.

  5. Operational Control Procedures for the Activated Sludge Process, Part I - Observations, Part II - Control Tests.

    ERIC Educational Resources Information Center

    West, Alfred W.

    This is the first in a series of documents developed by the National Training and Operational Technology Center describing operational control procedures for the activated sludge process used in wastewater treatment. Part I of this document deals with physical observations which should be performed during each routine control test. Part II…

  6. MONGOLS OF THE TWENTIETH CENTURY, PART II. URALIC AND ALTAIC SERIES, VOLUME 37, PART 2.

    ERIC Educational Resources Information Center

    RUPEN, ROBERT A.

    THIS BIBLIOGRAPHY DIRECTLY SUPPLEMENTS AND IS INTENDED AS AN INTEGRAL PART OF "MONGOLS OF THE TWENTIETH CENTURY, PART I." THE RANGE OF SUBJECT MATTER, HOWEVER, GOES FAR BEYOND THE SPECIFIC CONCERNS OF THE FIRST VOLUME, COVERING GENERAL AND SPECIFIC BIBLIOGRAPHIES, UNSIGNED REPORTS AND DOCUMENTS, ENCYCLOPEDIAS, OFFICIAL HISTORIES,…

  7. A Linear Stochastic Dynamical Model of ENSO. Part II: Analysis.

    NASA Astrophysics Data System (ADS)

    Thompson, C. J.; Battisti, D. S.

    2001-02-01

    In this study the behavior of a linear, intermediate model of ENSO is examined under stochastic forcing. The model was developed in a companion paper (Part I) and is derived from the Zebiak-Cane ENSO model. Four variants of the model are used whose stabilities range from slightly damped to moderately damped. Each model is run as a simulation while being perturbed by noise that is uncorrelated (white) in space and time. The statistics of the model output show the moderately damped models to be more realistic than the slightly damped models. The moderately damped models have power spectra that are quantitatively quite similar to observations, and a seasonal pattern of variance that is qualitatively similar to observations. All models produce ENSOs that are phase locked to the annual cycle, and all display the `spring barrier' characteristic in their autocorrelation patterns, though in the models this `barrier' occurs during the summer and is less intense than in the observations (inclusion of nonlinear effects is shown to partially remedy this deficiency). The more realistic models also show a decadal variability in the lagged autocorrelation pattern that is qualitatively similar to observations.Analysis of the models shows that the greatest part of the variability comes from perturbations that project onto the first singular vector, which then grow rapidly into the ENSO mode. Essentially, the model output represents many instances of the ENSO mode, with random phase and amplitude, stimulated by the noise through the optimal transient growth of the singular vectors.The limit of predictability for each model is calculated and it is shown that the more realistic (moderately damped) models have worse potential predictability (9-15 months) than the deterministic chaotic models that have been studied widely in the literature. The predictability limits are strongly correlated with the stability of the models' ENSO mode-the more highly damped models having much shorter

  8. Repulsive Interactions Induced by Specific Adsorption: Anomalous Step Diffusivity and Inadequacy of Nearest-Neighbor Ising Model (Part II Theory)

    NASA Astrophysics Data System (ADS)

    Ibach, Harald; Giesen, Margret; Al-Shakran, Mohammad; Kibler, Ludwig A.; Jacob, Timo

    2017-05-01

    This is Part II of two closely related papers, where we show that the strong repulsive interaction caused by specifically adsorbed anions leads to a failure of the nearest-neighbor Ising model to describe structures on electrode surfaces. In this part, an analytical form of the step diffusivity is derived in terms of nearest and next-nearest neighbor interactions for steps with a mean direction along < 110 > (the close-packed direction). With the help of a further analytical expression for the diffusivity of steps with < 100 > mean orientation a simple scheme is developed whereby the nearest and next-nearest interaction energies can be extracted from the experimental values for the diffusivity along the < 110 > - and < 100 > -directions. The method is applicable to repulsive and attractive next-nearest neighbor interactions, both for surfaces in vacuum and in contact with an electrolyte. An example is presented in Part I, where we apply our approach to Au(100) in Br--, Cl-- and SO42-containing electrolytes.

  9. Practice improvement, part II: update on patient communication technologies.

    PubMed

    Roett, Michelle A; Coleman, Mary Thoesen

    2013-11-01

    Patient portals (ie, secure web-based services for patient health record access) and secure messaging to health care professionals are gaining popularity slowly. Advantages of web portals include timely communication and instruction, access to appointments and other services, and high patient satisfaction. Limitations include inappropriate use, security considerations, organizational costs, and exclusion of patients who are uncomfortable with or unable to use computers. Attention to the organization's strategic plan and office policies, patient and staff expectations, workflow and communication integration, training, marketing, and enrollment can facilitate optimal use of this technology. Other communication technologies that can enhance patient care include automated voice or text reminders and brief electronic communications. Social media provide another method of patient outreach, but privacy and access are concerns. Incorporating telehealthcare (health care provided via telephone or Internet), providing health coaching, and using interactive health communication applications can improve patient knowledge and clinical outcomes and provide social support. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  10. Imaging of juvenile idiopathic arthritis. Part II: Ultrasonography and MRI

    PubMed Central

    Grochowska, Elżbieta; Gietka, Piotr; Płaza, Mateusz; Pracoń, Grzegorz; Saied, Fadhil; Walentowska-Janowicz, Marta

    2016-01-01

    Juvenile idiopathic arthritis is the most common autoimmune systemic disease of the connective tissue affecting individuals in the developmental age. Radiography, which was described in the first part of this publication, is the standard modality in the assessment of this condition. Ultrasound and magnetic resonance imaging enable early detection of the disease which affects soft tissues, as well as bones. Ultrasound assessment involves: joint cavities, tendon sheaths and bursae for the presence of synovitis, intraand extraarticular fat tissue to visualize signs of inflammation, hyaline cartilage, cartilaginous epiphysis and subchondral bone to detect cysts and erosions, and ligaments, tendons and their entheses for signs of enthesopathies and tendinopathies. Magnetic resonance imaging is indicated in children with juvenile idiopathic arthritis for assessment of inflammation in peripheral joints, tendon sheaths and bursae, bone marrow involvement and identification of inflammatory lesions in whole-body MRI, particularly when the clinical picture is unclear. Also, MRI of the spine and spinal cord is used in order to diagnose synovial joint inflammation, bone marrow edema and spondylodiscitis as well as to assess their activity, location, and complications (spinal canal stenosis, subluxation, e.g. in the atlantoaxial region). This article discusses typical pathological changes seen on ultrasound and magnetic resonance imaging. The role of these two methods for disease monitoring, its identification in the pre-clinical stage and establishing its remission are also highlighted. PMID:27679727

  11. Eponyms in cardiothoracic radiology--part II: vascular.

    PubMed

    Mohammed, Tan-Lucien H; Saettele, Megan R; Saettele, Timothy; Patel, Vikas; Kanne, Jeffrey P

    2014-01-01

    Eponyms serve the purpose of honoring individuals who have made important observations and discoveries. As with other fields of medicine, eponyms are frequently encountered in radiology, particularly in chest radiology. However, inappropriate use of an eponym may lead to potentially dangerous miscommunication. Moreover, an eponym may honor the incorrect person or a person who falls into disrepute. Despite their limitations, eponyms are still widespread in the medical literature. Furthermore, in some circumstances, more than one individual may have contributed to the description or discovery of a particular anatomical structure or disease, whereas in others, an eponym may have been incorrectly applied initially and propagated for years in the medical literature. Nevertheless, radiologic eponyms are a means of honoring those who have made lasting contributions to the field of radiology, and familiarity with these eponyms is critical for proper reporting and accurate communication. In addition, the acquisition of some historical knowledge about those whose names are associated with various structures or pathologic conditions conveys a sense of humanity in the science of medicine. In this second part of a multipart series, the authors discuss a number of chest radiology eponyms as they relate to the pulmonary vasculature, including relevant clinical and imaging features, as well biographic information of the respective eponym׳s namesake.

  12. Simulation of Slag Freeze Layer Formation: Part II: Numerical Model

    NASA Astrophysics Data System (ADS)

    Guevara, Fernando J.; Irons, Gordon A.

    2011-08-01

    The experiments from Part I with CaCl2-H2O solidification in a differentially heated, square cavity were simulated in two dimensions using a control volume technique in a fixed grid. The test conditions and physical properties of the fluid resulted in Prandtl and Rayleigh numbers in the range of 50 and 2.1 × 108, respectively, and the solidification was observed to be planar with dispersed solid particles. In the mathematical model, temperature-dependent viscosity and density functions were employed. To suppress velocities in the solid phase, various models were tested, and a high effective viscosity was found most appropriate. The results compare well with the experiments in terms of solid layer growth, horizontal and vertical velocities, heat transfer coefficients, and temperature distributions. Hydrodynamic boundary layers on the solidified front and on the hot vertical wall tend to be nonsymmetric, as well on the top and bottom adiabatic walls. The high viscosity value imposed on the two-phase zone affects the velocity profile close to the solid front and modifies the heat transfer rate.

  13. Medicine at the crossroads. Part II. Summary of completed project

    SciTech Connect

    1998-05-01

    Medicine at the crossroads (a.k.a. The Future of Medicine) is an 8-part series of one-hour documentaries which examines the scientific and social forces that have shaped the practice of medicine around the world. The series was developed and produced over a five-year period and in eleven countries. Among the major issues examined in the series are the education of medical practitioners and the communication of medical issues. The series also considers the dilemmas of modern medicine, including the treatment of the elderly and the dying, the myth of the quick fix in the face of chronic and incurable diseases such as HIV, and the far-reaching implications of genetic treatments. Finally, the series examines the global progress made in medical research and application, as well as the questions remaining to be answered. These include not only scientific treatment, but accessibility and other critical topics affecting the overall success of medical advances. Medicine at the crossroads is a co-production of Thirteen/WNET and BBC-TV in association with Television Espafiola SA (RTVE) and the Australian Broadcasting Corporation. Stefan Moore of Thirteen/WNET and Martin Freeth of BBC-TV are series producers. George Page is executive in charge of medicine at the crossroads. A list of scholarly advisors and a program synopses is attached.

  14. Practice improvement, part II: trends in employment versus private practice.

    PubMed

    Coleman, Mary Thoesen; Roett, Michelle A

    2013-11-01

    A growing percentage of physicians are selecting employment over solo practice, and fewer family physicians have hospital admission privileges. Results from surveys of recent medical school graduates indicate a high value placed on free time. Factors to consider when choosing a practice opportunity include desire for independence, decision-making authority, work-life balance, administrative responsibilities, financial risk, and access to resources. Compensation models are evolving from the simple fee-for-service model to include metrics that reward panel size, patient access, coordination of care, chronic disease management, achievement of patient-centered medical home status, and supervision of midlevel clinicians. When a practice is sold, tangible personal property and assets in excess of liabilities, patient accounts receivable, office building, and goodwill (ie, expected earnings) determine its value. The sale of a practice includes a broad legal review, addressing billing and coding deficiencies, noncompliant contractual arrangements, and potential litigations as well as ensuring that all employment agreements, leases, service agreements, and contracts are current, have been executed appropriately, and meet regulatory requirements. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  15. Biomimetic sensor for certain catecholamines employing copper(II) complex and silver nanoparticle modified glassy carbon paste electrode.

    PubMed

    Sanghavi, Bankim J; Mobin, Shaikh M; Mathur, Pradeep; Lahiri, Goutam K; Srivastava, Ashwini K

    2013-01-15

    A dimeric Cu(II) complex [Cu(μ(2)-hep)(hep-H)](2)·2ClO(4) (1) containing bidentate (hep-H=2-(2-hydroxyethyl)pyridine) ligand was synthesized and characterized by single crystal X-ray diffraction studies. Each Cu-ion in 1 is in a distorted square pyramidal geometry. Further 1 along with silver nanoparticles (SNPs) have been used as modifier in the construction of a biomimetic sensor (1-SNP-GCPE) for determining certain catecholamines viz., dopamine (DA), levodopa (l-Dopa), epinephrine (EP) and norepinephrine (NE) using cyclic voltammetry, chronocoulometry, electrochemical impedance spectroscopy and adsorptive stripping square wave voltammetry (AdSSWV). Finally, the catalytic properties of the sensor were characterized by chronoamperometry. Employing AdSSWV, the calibration curves showed linear response ranging between 10(-6) and 10(-9)M for all the four analytes with detection limits (S/N=3) of 8.52×10(-10)M, 2.41×10(-9)M, 3.96×10(-10)M and 3.54×10(-10)M for DA, l-Dopa, EP and NE respectively. The lifetime of the biomimetic sensor was 3 months at room temperature. The prepared modified electrode shows several advantages such as simple preparation method, high sensitivity, high stability, ease of preparation and regeneration of the electrode surface by simple polishing along with excellent reproducibility. The method has been applied for the selective and precise analysis of DA, l-Dopa, EP and NE in pharmaceutical formulations, urine and blood serum samples.

  16. Differential pulse anodic stripping voltammetric determination of lead(II) with a 1,4-bis(prop-2'-enyloxy)-9,10-anthraquinone modified carbon paste electrode.

    PubMed

    Mousavi, M F; Rahmani, A; Golabi, S M; Shamsipur, M; Sharghi, H

    2001-08-30

    A sensitive and selective method for the determination of lead(II) with a 1,4-bis(prop-2'-enyloxy)-9,10-anthraquinone (AQ) modified carbon paste electrode has been developed. The method is based on non-electrolytic preconcentration via complex formation with modifier, followed by an accumulation period with a negative potential (-1.5 V), and then by a proper anodic stripping. The analytical performance was evaluated with respect to the quantity of modifier in the paste, concentration of electrolyte solution, preconcentration time, lead(II) concentration, and other variables. A linear calibration graph was obtained in the concentration range 2.00x10(-9)-1.06x10(-5) M Pb(II) (n=21, r=0.9999) with 30 s preconcentration time. The detection limit was found to be 1x10(-9) M. For eight preconcentration/determination cycles, the differential pulse voltammetric response was reproduced with 5.0 and 3.7% relative standard deviations at 2.00x10(-8) and 2.00x10(-6) M Pb(II), respectively. Rapid and convenient renewal of electrode surface allows the use of a single modified electrode surface in multiple analytical determinations over several weeks. Many coexisting metal ions had little or no effect on the determination of lead(II). The developed method was applied to lead determination in waste waters.

  17. Highly sensitive amperometric sensor for micromolar detection of trichloroacetic acid based on multiwalled carbon nanotubes and Fe(II)-phtalocyanine modified glassy carbon electrode.

    PubMed

    Kurd, Masoumeh; Salimi, Abdollah; Hallaj, Rahman

    2013-04-01

    A highly sensitive electrochemical sensor for the detection of trichloroacetic acid (TCA) is developed by subsequent immobilization of phthalocyanine (Pc) and Fe(II) onto multiwalled carbon nanotubes (MWCNTs) modified glassy carbon (GC) electrode. The GC/MWCNTs/Pc/Fe(II) electrode showed a pair of well-defined and nearly reversible redox couple correspondent to (Fe(III)Pc/Fe(II)Pc) with surface-confined characteristics. The surface coverage (Γ) and heterogeneous electron transfer rate constant (ks) of immobilized Fe(II)-Pc were calculated as 1.26×10(-10) mol cm(-2) and 28.13 s(-1), respectively. Excellent electrocatalytic activity of the proposed GC/MWCNTs/Pc/Fe(II) system toward TCA reduction has been indicated and the three consequent irreversible peaks for electroreduction of CCl3COOH to CH3COOH have been clearly seen. The observed chronoamperometric currents are linearly increased with the concentration of TCA at concentration range up to 20mM. Detection limit and sensitivity of the modified electrode were 2.0 μM and 0.10 μA μM(-1) cm(-2), respectively. The applicability of the sensor for TCA detection in real samples was tested. The obtained results suggest that the proposed system can serve as a promising electrochemical platform for TCA detection.

  18. Research Summary No. 36-3, Volume I, Part II. Volume I, Part Two

    NASA Technical Reports Server (NTRS)

    1960-01-01

    The Research Summary is a bimonthly report of supporting research and development conducted at the Jet Propulsion Laboratory. This periodical is issued in three volumes. Volume I contains summaries of the work accomplished by the Space Sciences, Systems, Guidance and Control, and Telecommunications Divisions of the Laboratory. Volume II contains summaries of the work accomplished by the Physical Sciences, Engineering Mechanics, Engineering Facilities, and Propulsion Divisions. All work of a classified nature is contained in Volume Ill.

  19. Studies in Enrollment Trends and Patterns. Part II--Summer Quarter: 1940-1964.

    ERIC Educational Resources Information Center

    Schmid, Calvin F.; Watson, F. Jean

    This is the second part of a report on major facets of institutional change at the University of Washington. Part II is a detailed analysis of Summer Quarter students and covers: class differentials in enrollment trends; trends in undergraduate students by major field and college; trends in graduate and professional students by major field and…

  20. Medical Education: Barefoot Doctors, Health Care, Health Education, Nursing Education, Pharmacy Education, Part II.

    ERIC Educational Resources Information Center

    Parker, Franklin

    1987-01-01

    This is Part II of a two-part annotated bibliography of selected references on medical education in the People's Republic of China. The references date from 1913 to 1982. Most of the references are from the 1960's and 1970's. (RH)

  1. An Occupation and Participation Approach to Reading Intervention (OPARI) Part II: Pilot Clinical Application

    ERIC Educational Resources Information Center

    Grajo, Lenin C.; Candler, Catherine

    2016-01-01

    The Occupation and Participation Approach to Reading Intervention (OPARI) is an intervention approach for children with reading difficulties that emphasizes reading as an important occupation of children. Part I presented the theoretical basis of the OPARI. Part II describes a pilot clinical application of the OPARI. Guided by Schkade and…

  2. An Occupation and Participation Approach to Reading Intervention (OPARI) Part II: Pilot Clinical Application

    ERIC Educational Resources Information Center

    Grajo, Lenin C.; Candler, Catherine

    2016-01-01

    The Occupation and Participation Approach to Reading Intervention (OPARI) is an intervention approach for children with reading difficulties that emphasizes reading as an important occupation of children. Part I presented the theoretical basis of the OPARI. Part II describes a pilot clinical application of the OPARI. Guided by Schkade and…

  3. Why does Bangladesh remain so poor? Part II: eight answers.

    PubMed

    Maloney, C

    1985-01-01

    Bangladeshis of varying background all over the country were asked why they think poverty persists to such an extent in Bangladesh. Their answers provide a new perspective on the situation. The initial response often blames outside and natural causes -- floods, droughts, lack of resources, low demand for the country's exports, or historic exploitation. It is true that Bangladesh has virtually no mineral resources except gas. Yet, the soil, water, and human labor add up to a huge potential. The Third Five Year Plan emphasizes use of the soil, irrigation, tanks, rivers, and human labor. These provide the only hope for reducing poverty a little during the next 5 years. Bangladeshis as well as foreign observers most commonly cite overpopulation as the cause of poverty. Population growth is a cause of present poverty in Bangladesh but is not the only cause of poverty. The Third Five Year Plan goal to reduce annual growth to 1.8% is ambitious, but even if it is achieved the population will double in a few decades. As it would most likely be impossible for Bangladesh to support such numbers and maintain political and economic stability, such growth will have to be prevented. Poverty in Bangladesh is party a result of the long history of low urbanization, weak institutions, spotty and inadequate physical infrastructure, and insufficient entrapreneurship. Other reasons cited as causes of persisting poverty include illiteracy, idleness, class exploitation, the selfishness of individuals, and a lack of trust among people. All of the efforts of the poor themselves, various agencies, and the government, as examined in the 1st part of this discussion, fail to indicate any reason to hope that poverty in Bangladesh can be dramatically reduced any time soon. The Third Five Year Plan foresees a possible reduction of the number of those in poverty by 10%. According to the Plan itself, those in or near poverty comprise 85% of the people. The conditions under which the people of some

  4. Is extreme learning machine feasible? A theoretical assessment (part II).

    PubMed

    Lin, Shaobo; Liu, Xia; Fang, Jian; Xu, Zongben

    2015-01-01

    An extreme learning machine (ELM) can be regarded as a two-stage feed-forward neural network (FNN) learning system that randomly assigns the connections with and within hidden neurons in the first stage and tunes the connections with output neurons in the second stage. Therefore, ELM training is essentially a linear learning problem, which significantly reduces the computational burden. Numerous applications show that such a computation burden reduction does not degrade the generalization capability. It has, however, been open that whether this is true in theory. The aim of this paper is to study the theoretical feasibility of ELM by analyzing the pros and cons of ELM. In the previous part of this topic, we pointed out that via appropriately selected activation functions, ELM does not degrade the generalization capability in the sense of expectation. In this paper, we launch the study in a different direction and show that the randomness of ELM also leads to certain negative consequences. On one hand, we find that the randomness causes an additional uncertainty problem of ELM, both in approximation and learning. On the other hand, we theoretically justify that there also exist activation functions such that the corresponding ELM degrades the generalization capability. In particular, we prove that the generalization capability of ELM with Gaussian kernel is essentially worse than that of FNN with Gaussian kernel. To facilitate the use of ELM, we also provide a remedy to such a degradation. We find that the well-developed coefficient regularization technique can essentially improve the generalization capability. The obtained results reveal the essential characteristic of ELM in a certain sense and give theoretical guidance concerning how to use ELM.

  5. Neuromorphic meets neuromechanics, part II: the role of fusimotor drive

    NASA Astrophysics Data System (ADS)

    Jalaleddini, Kian; Minos Niu, Chuanxin; Chakravarthi Raja, Suraj; Sohn, Won Joon; Loeb, Gerald E.; Sanger, Terence D.; Valero-Cuevas, Francisco J.

    2017-04-01

    Objective. We studied the fundamentals of muscle afferentation by building a Neuro-mechano-morphic system actuating a cadaveric finger. This system is a faithful implementation of the stretch reflex circuitry. It allowed the systematic exploration of the effects of different fusimotor drives to the muscle spindle on the closed-loop stretch reflex response. Approach. As in Part I of this work, sensory neurons conveyed proprioceptive information from muscle spindles (with static and dynamic fusimotor drive) to populations of α-motor neurons (with recruitment and rate coding properties). The motor commands were transformed into tendon forces by a Hill-type muscle model (with activation-contraction dynamics) via brushless DC motors. Two independent afferented muscles emulated the forces of flexor digitorum profundus and the extensor indicis proprius muscles, forming an antagonist pair at the metacarpophalangeal joint of a cadaveric index finger. We measured the physical response to repetitions of bi-directional ramp-and-hold rotational perturbations for 81 combinations of static and dynamic fusimotor drives, across four ramp velocities, and three levels of constant cortical drive to the α-motor neuron pool. Main results. We found that this system produced responses compatible with the physiological literature. Fusimotor and cortical drives had nonlinear effects on the reflex forces. In particular, only cortical drive affected the sensitivity of reflex forces to static fusimotor drive. In contrast, both static fusimotor and cortical drives reduced the sensitivity to dynamic fusimotor drive. Interestingly, realistic signal-dependent motor noise emerged naturally in our system without having been explicitly modeled. Significance. We demonstrate that these fundamental features of spinal afferentation sufficed to produce muscle function. As such, our Neuro-mechano-morphic system is a viable platform to study the spinal mechanisms for healthy muscle function—and its

  6. Fundamentals of Trapped Ion Mobility Spectrometry Part II: Fluid Dynamics

    NASA Astrophysics Data System (ADS)

    Silveira, Joshua A.; Michelmann, Karsten; Ridgeway, Mark E.; Park, Melvin A.

    2016-04-01

    Trapped ion mobility spectrometry (TIMS) is a new high resolution (R up to ~300) separation technique that utilizes an electric field to hold ions stationary against a moving gas. Recently, an analytical model for TIMS was derived and, in part, experimentally verified. A central, but not yet fully explored, component of the model involves the fluid dynamics at work. The present study characterizes the fluid dynamics in TIMS using simulations and ion mobility experiments. Results indicate that subsonic laminar flow develops in the analyzer, with pressure-dependent gas velocities between ~120 and 170 m/s measured at the position of ion elution. One of the key philosophical questions addressed is: how can mobility be measured in a dynamic system wherein the gas is expanding and its velocity is changing? We noted previously that the analytically useful work is primarily done on ions as they traverse the electric field gradient plateau in the analyzer. In the present work, we show that the position-dependent change in gas velocity on the plateau is balanced by a change in pressure and temperature, ultimately resulting in near position-independent drag force. That the drag force, and related variables, are nearly constant allows for the use of relatively simple equations to describe TIMS behavior. Nonetheless, we derive a more comprehensive model, which accounts for the spatial dependence of the flow variables. Experimental resolving power trends were found to be in close agreement with the theoretical dependence of the drag force, thus validating another principal component of TIMS theory.

  7. Stress analysis in oral obturator prostheses, part II: photoelastic imaging

    NASA Astrophysics Data System (ADS)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; da Silva, Emily Vivianne Freitas; Haddad, Marcela Filié; Moreno, Amália; Zahoui, Abbas; dos Santos, Daniela Micheline

    2014-06-01

    In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.

  8. FPGA-accelerated adaptive optics wavefront control part II

    NASA Astrophysics Data System (ADS)

    Mauch, S.; Barth, A.; Reger, J.; Reinlein, C.; Appelfelder, M.; Beckert, E.

    2015-03-01

    We present progressive work that is based on our recently developed rapid control prototyping system (RCP), designed for the implementation of high-performance adaptive optical control algorithms using a continuous de-formable mirror (DM). The RCP system, presented in 2014, is resorting to a Xilinx Kintex-7 Field Programmable Gate Array (FPGA), placed on a self-developed PCIe card, and installed on a high-performance computer that runs a hard real-time Linux operating system. For this purpose, algorithms for the efficient evaluation of data from a Shack-Hartmann wavefront sensor (SHWFS) on an FPGA have been developed. The corresponding analog input and output cards are designed for exploiting the maximum possible performance while not being constrained to a specific DM and control algorithm due to the RCP approach. In this second part of our contribution, we focus on recent results that we achieved with this novel experimental setup. By presenting results which are far superior to the former ones, we further justify the deployment of the RCP system and its required time and resources. We conducted various experiments for revealing the effective performance, i.e. the maximum manageable complexity in the controller design that may be achieved in real-time without performance losses. A detailed analysis of the hidden latencies is carried out, showing that these latencies have been drastically reduced. In addition, a series of concepts relating the evaluation of the wavefront as well as designing and synthesizing a wavefront are thoroughly investigated with the goal to overcome some of the prevalent limitations. Furthermore, principal results regarding the closed-loop performance of the low-speed dynamics of the integrated heater in a DM concept are illustrated in detail; to be combined with the piezo-electric high-speed actuators in the next step

  9. Surface grafted chitosan gels. Part II. Gel formation and characterization.

    PubMed

    Liu, Chao; Thormann, Esben; Claesson, Per M; Tyrode, Eric

    2014-07-29

    Responsive biomaterial hydrogels attract significant attention due to their biocompatibility and degradability. In order to make chitosan based gels, we first graft one layer of chitosan to silica, and then build a chitosan/poly(acrylic acid) multilayer using the layer-by-layer approach. After cross-linking the chitosan present in the polyelectrolyte multilayer, poly(acrylic acid) is partly removed by exposing the multilayer structure to a concentrated carbonate buffer solution at a high pH, leaving a surface-grafted cross-linked gel. Chemical cross-linking enhances the gel stability against detachment and decomposition. The chemical reaction between gluteraldehyde, the cross-linking agent, and chitosan was followed in situ using total internal reflection Raman (TIRR) spectroscopy, which provided a molecular insight into the complex reaction mechanism, as well as the means to quantify the cross-linking density. The amount of poly(acrylic acid) trapped inside the surface grafted films was found to decrease with decreasing cross-linking density, as confirmed in situ using TIRR, and ex situ by Fourier transform infrared (FTIR) measurements on dried films. The responsiveness of the chitosan-based gels with respect to pH changes was probed by quartz crystal microbalance with dissipation (QCM-D) and TIRR. Highly cross-linked gels show a small and fully reversible behavior when the solution pH is switched between pH 2.7 and 5.7. In contrast, low cross-linked gels are more responsive to pH changes, but the response is fully reversible only after the first exposure to the acidic solution, once an internal restructuring of the gel has taken place. Two distinct pKa's for both chitosan and poly(acrylic acid), were determined for the cross-linked structure using TIRR. They are associated with populations of chargeable groups displaying either a bulk like dissociation behavior or forming ionic complexes inside the hydrogel film.

  10. Fundamentals of Trapped Ion Mobility Spectrometry Part II: Fluid Dynamics.

    PubMed

    Silveira, Joshua A; Michelmann, Karsten; Ridgeway, Mark E; Park, Melvin A

    2016-04-01

    Trapped ion mobility spectrometry (TIMS) is a new high resolution (R up to ~300) separation technique that utilizes an electric field to hold ions stationary against a moving gas. Recently, an analytical model for TIMS was derived and, in part, experimentally verified. A central, but not yet fully explored, component of the model involves the fluid dynamics at work. The present study characterizes the fluid dynamics in TIMS using simulations and ion mobility experiments. Results indicate that subsonic laminar flow develops in the analyzer, with pressure-dependent gas velocities between ~120 and 170 m/s measured at the position of ion elution. One of the key philosophical questions addressed is: how can mobility be measured in a dynamic system wherein the gas is expanding and its velocity is changing? We noted previously that the analytically useful work is primarily done on ions as they traverse the electric field gradient plateau in the analyzer. In the present work, we show that the position-dependent change in gas velocity on the plateau is balanced by a change in pressure and temperature, ultimately resulting in near position-independent drag force. That the drag force, and related variables, are nearly constant allows for the use of relatively simple equations to describe TIMS behavior. Nonetheless, we derive a more comprehensive model, which accounts for the spatial dependence of the flow variables. Experimental resolving power trends were found to be in close agreement with the theoretical dependence of the drag force, thus validating another principal component of TIMS theory.

  11. Overactive bladder – 18 years – Part II

    PubMed Central

    Truzzi, Jose Carlos; Gomes, Cristiano Mendes; Bezerra, Carlos A.; Plata, Ivan Mauricio; Campos, Jose; Garrido, Gustavo Luis; Almeida, Fernando G.; Averbeck, Marcio Augusto; Fornari, Alexandre; Salazar, Anibal; Dell’Oro, Arturo; Cintra, Caio; Sacomani, Carlos Alberto Ricetto; Tapia, Juan Pablo; Brambila, Eduardo; Longo, Emilio Miguel; Rocha, Flavio Trigo; Coutinho, Francisco; Favre, Gabriel; Garcia, José Antonio; Castaño, Juan; Reyes, Miguel; Leyton, Rodrigo Eugenio; Ferreira, Ruiter Silva; Duran, Sergio; López, Vanda; Reges, Ricardo

    2016-01-01

    ABSTRACT Traditionally, the treatment of overactive bladder syndrome has been based on the use of oral medications with the purpose of reestablishing the detrusor stability. The recent better understanding of the urothelial physiology fostered conceptual changes, and the oral anticholinergics – pillars of the overactive bladder pharmacotherapy – started to be not only recognized for their properties of inhibiting the detrusor contractile activity, but also their action on the bladder afference, and therefore, on the reduction of the symptoms that constitute the syndrome. Beta-adrenergic agonists, which were recently added to the list of drugs for the treatment of overactive bladder, still wait for a definitive positioning – as either a second-line therapy or an adjuvant to oral anticholinergics. Conservative treatment failure, whether due to unsatisfactory results or the presence of adverse side effects, define it as refractory overactive bladder. In this context, the intravesical injection of botulinum toxin type A emerged as an effective option for the existing gap between the primary measures and more complex procedures such as bladder augmentation. Sacral neuromodulation, described three decades ago, had its indication reinforced in this overactive bladder era. Likewise, the electric stimulation of the tibial nerve is now a minimally invasive alternative to treat those with refractory overactive bladder. The results of the systematic literature review on the oral pharmacological treatment and the treatment of refractory overactive bladder gave rise to this second part of the review article Overactive Bladder – 18 years, prepared during the 1st Latin-American Consultation on Overactive Bladder. PMID:27176185

  12. The intra-uterine device. Part II: technical problems.

    PubMed

    Alexander, I

    1980-10-01

    In discussing the technical problems associated with the IUD, focus is on the basic insertion technique, the technique to use with the various IUDs (Copper 7, Lippes Loop, Copper T models, the Saf-T-coil, and the multiload 250), the timing of the insertion, and removal of the IUD. Bimanual examination of the pelvis must be performed before an IUD is inserted. Prior to starting the insertion, the patient should be given an explanation of what is to be done. As patients are unfamiliar with the appearance of most of the instruments, it is advisable to keep them from view. Having visualized the cervix and fixed the blades of the Cusco speculum in the open position, the cervix can be seized with a single toothed tenaculum or 7 inch Allis forceps. It is generally necessary to steady the cervix with a forcep as it straightens out the canal and uterine flexion. Sounding the uterine cavity will reveal its length and confirm any angulation. On occasion it is impossible to sound the cavity because the internal os is too tight or the endocervical canal has a pinhole external os. Force should be avoided. High fundal placement without perforating the uterus is the objective when inserting any IUD, and this is particularly important with the copper IUDs which depend on a close association of their copper elements to the endometrium. Generally, it is easier to insert a coil towards the end of the period when the cervix is partly dilated and any bleeding that occurs is masked. Insertion following abortion is commonly performed, and encouraging results have been achieved with insertions immediately postpartum. Removal can be done at any time.

  13. Electrocatalytic oxidation of 2-mercaptoethanol using modified glassy carbon electrode by MWCNT in combination with unsymmetrical manganese (II) Schiff base complexes

    SciTech Connect

    Mohebbi, Sajjad Eslami, Saadat

    2015-06-15

    Highlights: • High electocatalytic efficiency and stability of modified hybrid electrode GC/MWCNTs/MnSaloph. • Direct reflection of catalytic activity of manganese complexes on electrocatalytic oxidation of 2-ME. • Decreasing overpotential and increasing catalytic peak current toward oxidation of 2-ME. • Deposition of range of novel substituted N{sub 2}O{sub 2} Saloph complexes of manganese(II) on GCE/MWCNT. • Enhancement of electrocatalytic oxidation activity upon electron donating substitutions on the Saloph. - Abstract: The performance of modified hybrid glassy carbon electrode with composite of carbon nanotubes and manganese complexes for the electrocatalytic oxidation of 2-mercaptoethanol is developed. GC electrode was modified using MWCNT and new N{sub 2}O{sub 2} unsymmetrical tetradentate Schiff base complexes of manganese namely Manganese Saloph complexes 1-5, with general formula Mn[(5-x-4-y-Sal)(5-x′-4-y′-Sal) Ph], where x, x′ = H, Br, NO{sub 2} and y, y′ = H, MeO. Direct immobilization of CNT on the surface of GCE is performed by abrasive immobilization, and then modified by manganese(II) complexes via direct deposition method. These novel modified electrodes clearly demonstrate the necessity of modifying bare carbon electrodes to endow them with the desired behavior and were identified by HRTEM. Also complexes were characterized by elemental analyses, MS, UV–vis and IR spectroscopy. Modified hybrid GC/MWCNT/MnSaloph electrode exhibits strong and stable electrocatalytic activity towards the electrooxidation of 2-mercaptoethanol molecules in comparison with bare glassy carbon electrode with advantages of very low over potential and high catalytic current. Such ability promotes the thiol’s electron transfer reaction. Also, electron withdrawing substituent on the Saloph was enhanced electrocatalytic oxidation activity.

  14. Part I: Microscopic description of liquid He II. Part II: Uniformly approximated WKB method as used for the calculation of phase shifts in heavy-ion collision problems

    SciTech Connect

    Suebka, P.

    1984-01-01

    In Part I, the excitation spectrum of liquid He II is obtained using the two-body potential consists of a hardcore potential plus an outside attractive potential. The sum of two gaussian potential of Khanna and Das which is similar to the Lennard-Jones potential is chosen as the attractive potential. The t-matrix method due to Brueckner and Sawada is adopted with modifications to replace the interaction potential. The spectrum gives the phonon branch and the roton dip which resemble the excitation spectrum for liquid He II. The temperature dependence of the excitation spectrum enters into calculation through the zero-momentum state occupation number. A better approximation of thermodynamic functions is obtained by extending Landau's theory to the situation where the excitation is a function of temperature as well as of momentum. Our thermodynamic calculations also bear qualitative agreement with measurements on He II as expected.

  15. Addressing future challenges for cancer services: part II.

    PubMed

    Maher, Jane; Radford, Gina

    2016-02-01

    Jane Maher & Gina Radford speak to Gemma Westcott, Commissioning Editor Jane Maher has been Macmillan's Chief Medical Officer since 1999 and now shares the role as Joint Chief Medical Officer with general practitioner Rosie Loftus, reflecting the growing need for specialists and generalists to work more effectively together. She has been an National Health Service (NHS) improvement clinical leader for over 10 years and is a Consultant Clinical Oncologist at Mount Vernon Cancer Centre and Hillingdon Hospital where she has worked for more than 20 years, during which she helped develop nonsurgical oncology services in five district general hospitals. She is a senior Clinical Lecturer at University College London and Visiting Professor in Cancer and Supportive Care at the Centre for Complexity Management at the University of Hertfordshire. Jane chaired the Maher Committee for the Department of Health in 1995, led the UK National Audit of Late Effects Pelvic Radiotherapy for the Royal College of Radiologists (RCR) in 2000 and, most recently, chaired the National Cancer Survivorship Initiative Consequences of Treatment work stream. She co-founded one of the first Cancer Support and Information services in the UK, winning the Nye Bevan award in 1992 and there are now more than 60 units based on this model. She is a member of the Older People and Cancer Clinical Advisory Group. She has written more than 100 published articles and is a UK representative for cancer survivorship in Europe and advises on cancer survivorship programs in Denmark and Canada. Gina Radford is Deputy Chief Medical Officer for England, a post she took up in January 2015. Prior to that, she has held a number of roles in public health, at local and regional level. Most recently she was Centre Director for Anglia and Essex for Public Health England, and as a part of that role helped lead nationally on the public health response to Ebola. She was until very recently Chair of one of the NICE public health

  16. PROBABILITY BASED CORROSION CONTROL FOR WASTE TANKS - PART II

    SciTech Connect

    Hoffman, E.; Edwards, T.

    2010-12-09

    As part of an ongoing study to evaluate the discontinuity in the corrosion controls at the SRS tank farm, a study was conducted this year to assess the minimum concentrations below 1 molar nitrate, see Figure 1. Current controls on the tank farm solution chemistry are in place to prevent the initiation and propagation of pitting and stress corrosion cracking in the primary steel waste tanks. The controls are based upon a series of experiments performed with simulated solutions on materials used for construction of the tanks, namely ASTM A537 carbon steel (A537). During FY09, an experimental program was undertaken to investigate the risk associated with reducing the minimum molar nitrite concentration required to confidently inhibit pitting in dilute solutions (i.e., less than 1 molar nitrate). The experimental results and conclusions herein provide a statistical basis to quantify the probability of pitting for the tank wall exposed to various solutions with dilute concentrations of nitrate and nitrite. Understanding the probability for pitting will allow the facility to make tank-specific risk-based decisions for chemistry control. Based on previous electrochemical testing, a statistical test matrix was developed to refine and solidify the application of the statistical mixture/amount model to corrosion of A537 steel. A mixture/amount model was identified based on statistical analysis of recent and historically collected electrochemical data. This model provides a more complex relationship between the nitrate and nitrite concentrations and the probability of pitting than is represented by the model underlying the current chemistry control program, and its use may provide a technical basis for the utilization of less nitrite to inhibit pitting at concentrations below 1 molar nitrate. FY09 results fit within the mixture/amount model, and further refine the nitrate regime in which the model is applicable. The combination of visual observations and cyclic

  17. Nurse staffing in a decentralized organization: part II.

    PubMed

    Althaus, J N; Hardyck, N M; Pierce, P B; Rodgers, M S

    1982-04-01

    It must be emphasized that none of the steps described in this planning process emerged overnight. Rather, they were achieved through a process of evolution, sometimes through trial and error, and always with consultation and participation by many members of the hospital nursing staff. Participation by many in the process of planning for a workable staffing system has been essential to its success. Indeed, creative scheduling by the head nurse is possible because of the way in which the system has been organized. The fact that head nurses are responsible for staffing their own units makes it infinitely easier for them to see what they need to make their units operate effectively and efficiently. Creative scheduling includes the possibility of arranging nurses' hours outside the rigid three-shift schedule used by so many hospitals. Many El Camino nurses now report for work at different hours. In addition, the use of flexible work weeks has proven valuable. Some head nurses now allow for a ten-hour, four-day work week; in emergency staffing situations there have, on occasion, been twelve-hour days. Even as this system evolves, it faces change. Just as the requirements for staff cannot be rigid, so must problem solving be flexible and constantly under review. The fact that El Camino believes in constant monitoring of its system is essential to its success. A key philosophical foundation of decentralization is that it must be subject to change. This is no less true in staffing than in other parts of the decentralization structure. By agreeing that change is constant and necessary and that participation is required at all levels of the staffing planning process, we have constructed the outlines of a system that will work in the future as well as it does in the present. Our system centers around the head nurses. It involves their planning; thus it also involves the support of those members of the nursing staff who can provide essential information. But the decisions

  18. Cardiovascular magnetic resonance physics for clinicians: part II

    PubMed Central

    2012-01-01

    This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described in part I, it briefly discusses further approaches to accelerate image acquisition. It then continues by showing in detail how the contrast behaviour of black blood fast spin echo and bright blood cine gradient echo techniques can be modified by adding rf preparation pulses to derive a number of more specialised pulse sequences. The simplest examples described include T2-weighted oedema imaging, fat suppression and myocardial tagging cine pulse sequences. Two further important derivatives of the gradient echo pulse sequence, obtained by adding preparation pulses, are used in combination with the administration of a gadolinium-based contrast agent for myocardial perfusion imaging and the assessment of myocardial tissue viability using a late gadolinium enhancement (LGE) technique. These two imaging techniques are discussed in more detail, outlining the basic principles of each pulse sequence, the practical steps required to achieve the best results in a clinical setting and, in the case of perfusion, explaining some of the factors that influence current approaches to perfusion image analysis. The key principles of contrast-enhanced magnetic resonance angiography (CE-MRA) are also explained in detail, especially focusing on timing of the acquisition following contrast agent bolus administration, and current approaches to achieving time resolved MRA. Alternative MRA techniques that do not require the use of an endogenous contrast agent are summarised, and the specialised pulse sequence used to image the coronary arteries, using respiratory navigator gating, is described in detail. The article concludes by explaining the principle behind phase contrast imaging techniques

  19. Implementing a predictive modeling program, part II: Use of motivational interviewing in a predictive modeling program.

    PubMed

    Calhoun, Jean; Admire, Kaye S

    2005-01-01

    This is the second article of a two-part series about issues encountered in implementing a predictive modeling program. Part I looked at how to effectively implement a program and discussed helpful hints and lessons learned for case managers who are required to change their approach to patients. In Part II, we discuss the readiness to change model, examine the spirit of motivational interviewing and related techniques, and explore how motivational interviewing is different from more traditional interviewing and assessment methods.

  20. Guidelines for clinical engineering programs--Part I: guidelines for electrical isolation; Part II: performance evaluation of clinical engineering programs.

    PubMed

    Ridgway, M

    1980-01-01

    This series presents guidelines for: electrically isolated inputs and outputs; measuring the performance of hospital biomedical engineering programs; evaluating the risk of electric shock in hospitals; and for isolated power in anesthetizing locations. In Part I, specific recommendations are given for the use of insulated approach, battery-powered monitors in surgery, and for isolation requirements for devices connected to cardiac leads. In Part II, checklists are provided for the self-evaluation of an in-house, biomedical engineering staff. Parts III and IV, in future issues of this Journal, will include discussion of the theoretical electrical hazard potential in reference to the use of isolated power systems. The question of whether isolated power should be required in all anesthetizing locations will be discussed in Part IV.

  1. On Idiosyncratic Systems. Part I. Idiosyncratic Systems. Part II. On Being Creative with Computer Aided Design.

    DTIC Science & Technology

    1977-03-31

    Catholic, good singer, vowel at the end of his name , likes pasta and red wine . Traversing this continuum has the intriguing property of reordering...feeling of transcendence , an aesthetic pleasure , or a good laugh. While one is 1101 Steven Coons, Computer graphics, initrodu ctionu . no less...a t i v - ’ - t , cL l e m s i - i - aesthetics , vol. 10, January 1970, 58—70. ‘.- i : i c~~, I:i tertia t nos ,ri l__liOirt:al ob ts:t,”tsa

  2. Synchrotron X-ray CT characterization of titanium parts fabricated by additive manufacturing. Part II. Defects.

    PubMed

    Scarlett, Nicola Vivienne Yorke; Tyson, Peter; Fraser, Darren; Mayo, Sheridan; Maksimenko, Anton

    2016-07-01

    Synchrotron X-ray tomography (SXRT) has been applied to the study of defects within three-dimensional printed titanium parts. These parts were made using the Arcam EBM(®) (electron beam melting) process which uses powdered titanium alloy, Ti64 (Ti alloy with approximately 6%Al and 4%V) as the feed and an electron beam for the sintering/welding. The experiment was conducted on the Imaging and Medical Beamline of the Australian Synchrotron. The samples represent a selection of complex shapes with a variety of internal morphologies. Inspection via SXRT has revealed a number of defects which may not otherwise have been seen. The location and nature of such defects combined with detailed knowledge of the process conditions can contribute to understanding the interplay between design and manufacturing strategy. This fundamental understanding may subsequently be incorporated into process modelling, prediction of properties and the development of robust methodologies for the production of defect-free parts.

  3. Helping Children Cope with Fears and Stress. Part I: Discussion and Activities. Part II: Facilitator's Guide.

    ERIC Educational Resources Information Center

    Robinson, Edward H.; And Others

    How fears, phobias, anxiety and stress develop in elementary school students and how these students can be assisted in coping with fears and stress are discussed in this book. Part 1, "Discussion and Activities," contains six sections. Section 1 presents an overview of fears, and stress in children. Section 2 presents 12 fear-specific activities…

  4. Factors Related to the Pronunciation of Vowel Clusters. Part II (of 3 Parts).

    ERIC Educational Resources Information Center

    Johnson, Dale D.

    Children's pronunciations of vowel clusters in synthetic words were analyzed in relation to common English words containing the same vowel clusters. Subjects were 436 elementary students of both high and low reading levels from a suburban, an urban, and a rural community. Conclusions of the study, reported in Part 2, were (1) pronunciations more…

  5. The Didactics of Biology. A Selected Bibliography for 1979. Part I [and] Part II.

    ERIC Educational Resources Information Center

    Altmann, Antonin, Ed.; Lipertova, Pavla, Ed.

    Selected articles on various aspects of biology teaching published in 1979 have been annotated in this two-part bibliography. Entries from 18 journals representing 11 different countries are presented according to a topic area classification scheme listed in the table of contents. Countries represented include: Australia; Bulgaria; Czechoslovakia;…

  6. The Didactics of Biology. A Selected Bibliography for 1979. Part I [and] Part II.

    ERIC Educational Resources Information Center

    Altmann, Antonin, Ed.; Lipertova, Pavla, Ed.

    Selected articles on various aspects of biology teaching published in 1979 have been annotated in this two-part bibliography. Entries from 18 journals representing 11 different countries are presented according to a topic area classification scheme listed in the table of contents. Countries represented include: Australia; Bulgaria; Czechoslovakia;…

  7. Ontario Universities Benefits Survey 1994-96. Part I: Benefits Excluding Pensions [and] Part II: Pensions.

    ERIC Educational Resources Information Center

    Council of Ontario Universities, Toronto.

    This report presents data from a survey of Ontario (Canada) universities concerning employment benefits offered in 1994-96. Part 1 covers benefits other than pensions. Tables display the information on particular benefits institution-by-institution including: administration and insurance plans, communication of benefits, proposed changes, life and…

  8. Ontario Universities Benefits Survey, 1993-94, Part I, Benefits Excluding Pensions [and] Part II: Pensions.

    ERIC Educational Resources Information Center

    Council of Senior Administrative Officers--Universities of Ontario, Toronto.

    This report presents data from a survey of Ontario (Canada) universities concerning employment benefits offered in 1993-94. Part I covers benefits other than pensions. Tables display the information on particular benefits institution-by-institution including: administration and insurance plans, communication of benefits, proposed changes,…

  9. Ontario Universities Benefits Survey 1994-96. Part I: Benefits Excluding Pensions [and] Part II: Pensions.

    ERIC Educational Resources Information Center

    Council of Ontario Universities, Toronto.

    This report presents data from a survey of Ontario (Canada) universities concerning employment benefits offered in 1994-96. Part 1 covers benefits other than pensions. Tables display the information on particular benefits institution-by-institution including: administration and insurance plans, communication of benefits, proposed changes, life and…

  10. Research and Development: A Complex Relationship Part I [and] Part II.

    ERIC Educational Resources Information Center

    Pollard, John Douglas Edward

    Part 1 of this document describes the background, format, and early groundwork that went into the development of a test sponsored entirely by private enterprise. The discipline imposed by a financial bottom line imposes special pressures but also offers new opportunities. This private enterprise model is a multi-constructional process where…

  11. Calcium phosphates deposited on titanium electrode surface--part 1: Effect of the electrode polarity and oxide film on the deposited materials.

    PubMed

    Okawa, Seigo; Watanabe, Kouichi; Kanatani, Mitsugu

    2013-01-01

    We report experimental results about the effect of polarity of electrode and anodized titanium oxide film on the deposited materials by electrolysis of an acidic calcium phosphate solution. Mirror-polished titanium and anodized titanium were used as anode or cathode, and a Pt plate was used as a counter electrode. The load voltage was held constant at 20 VDC. No deposited materials were found on the anode surface. On the other hand, dicalcium phosphate dihydrate (DCPD) was deposited on the cathode surface at the beginning of the electrolysis. After the electrolysis time 600 s, the non-stoichiometric hydroxyapatite (HAp) with several hundred nanometers was formed on the specimen surface. Based on X-ray photoelectron spectroscopy data, the anodized oxide film contained both P(5+) and P(3+) ions. This characteristic of the oxide film and the electrolysis conditions were related to the behavior of the deposition of ultra fine HAp with high crystallinity.

  12. A novel and sensitive carbon paste electrode with clinoptilolite nano-particles containing hexadecyltrimethyl ammonium surfactant and dithizone for the voltammetric determination of Sn(II).

    PubMed

    Niknezhadi, Azin; Nezamzadeh-Ejhieh, Alireza

    2017-09-01

    Clinoptilolite nano-particles (CNP) were modified by hexadecyltrimethyl ammonium bromide surfactant (HDTMA) and dithizone (DZ). The modified zeolite was then used for the modification of carbon paste electrode (CPE). The resulted CNP-HDTMA-DZ-CPE was finally used for the voltammetric determination of Sn(II) in aqueous solution. The raw and modified CNP was characterized by SEM-EDX, BET, TG-DTG and FTIR techniques. The best voltammetric response was obtained in 0.1molL(-1) NaNO3+HCl at pH 2.2 as supporting electrolyte. The electrode showed a linear response in the concentration range of 1×10(-8) to 1×10(-2)molL(-1)Sn(II) with LOD about 9×10(-9)molL(-1)Sn(II). The electrode showed good selectivity and applicability for the determination of Sn(II) in real samples such as river water, an steel company wastewater, tomato paste and a canned tuna fish. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Mercury(II) trace detection by a gold nanoparticle-modified glassy carbon electrode using square-wave anodic stripping voltammetry including a chloride desorption step.

    PubMed

    Laffont, Laure; Hezard, Teddy; Gros, Pierre; Heimbürger, Lars-Eric; Sonke, Jeroen E; Behra, Philippe; Evrard, David

    2015-08-15

    Gold nanoparticles (AuNPs) were deposited on a glassy carbon (GC) substrate by constant potential electrolysis and characterized by cyclic voltammetry in H2SO4 and field emission gun scanning electron microscopy (FEG-SEM). The modified AuNPs-GC electrode was used for low Hg(II) concentration detection using a Square Wave Anodic Stripping Voltammetry (SWASV) procedure which included a chloride desorption step. The comparison of the obtained results with our previous work in which no desorption step was used showed that this latter step significantly improved the analytical performances, providing a three time higher sensitivity and a limit of detection of 80pM for 300s preconcentration, as well as a lower average standard deviation. The influence of chloride concentration on the AuNPs-GC electrode response to Hg(II) trace amounts was also studied and its optimal value confirmed to be in the 10(-2)M range. Finally, the AuNPs-GC electrode was used for the determination of Hg(II) in a natural groundwater sample from south of France. By using a preconcentration time of 3000s, a Hg(II) concentration of 19±3pM was found, which compared well with the result obtained by cold vapor atomic fluorescence spectroscopy (22±2pM).

  14. Preconcentration and determination of mercury(II) at a chemically modified electrode containing 3-(2-thioimidazolyl)propyl silica gel.

    PubMed

    Dias Filho, Newton L; do Carmo, Devaney R; Caetano, Laércio; Rosa, André H

    2005-11-01

    A mercury-sensitive chemically modified graphite paste electrode was constructed by incorporating modified silica gel into a conventional graphite paste electrode. The functional group attached to the (3-chloropropyl) silica gel surface was 2-mercaptoimidazole, giving a new product denoted by 3-(2-thioimidazolyl)propyl silica gel, which is able to complex mercury ions. Mercury was chemically adsorbed on the modified graphite paste electrode containing 3-(2-thioimidazolyl)propyl silica (TIPSG GPE) by immersion in a Hg(II) solution, and the resultant surface was characterized by cyclic and differential pulse anodic stripping voltammetry. One cathodic peak at 0.1 V and other anodic peak at 0.34 V were observed on scanning the potential from -0.1 to 0.8 V (0.01 M KNO3; v = 2.0 mV s(-1) vs. Ag/AgCl). The anodic peak at 0.34 V show an excellent sensitivity for Hg(II) ions in the presence of several foreign ions. A calibration graph covering the concentration range from 0.02 to 2 mg L(-1) was obtained. The detection limit was estimated to be 5 microg L(-1). The precision for six determinations of 0.05 and 0.26 mg L(-1) Hg(II) was 3.0 and 2.5% (relative standard deviation), respectively. The method can be used to determine the concentration of mercury(II) in natural waters contaminated by this metal.

  15. Understanding Medicines: Conceptual Analysis of Nurses' Needs for Knowledge and Understanding of Pharmacology (Part I). Understanding Medicines: Extending Pharmacology Education for Dependent and Independent Prescribing (Part II).

    ERIC Educational Resources Information Center

    Leathard, Helen L.

    2001-01-01

    Part I reviews what nurses need to know about the administration and prescription of medicines. Part II addresses drug classifications, actions and effects, and interactions. Also discussed are the challenges pharmacological issues pose for nursing education. (SK)

  16. Direct Experimental Probe of the Ni(II)/Ni(III)/Ni(IV) Redox Evolution in LiNi0.5Mn1.5O4 Electrodes

    DOE PAGES

    Qiao, Ruimin; Wray, L. Andrew; Kim, Jung -Hyun; ...

    2015-11-11

    The LiNi0.5Mn1.5O4 spinel is an appealing cathode material for next generation rechargeable Li-ion batteries due to its high operating voltage of ~4.7 V (vs Li/Li+). Although it is widely believed that the full range of electrochemical cycling involves the redox of Ni(II)/(IV), it has not been experimentally clarified whether Ni(III) exists as the intermediate state or a double-electron transfer takes place. Here, combined with theoretical calculations, we show unambiguous spectroscopic evidence of the Ni(III) state when the LiNi0.5Mn1.5O4 electrode is half charged. This provides a direct verification of single-electron-transfer reactions in LiNi0.5Mn1.5O4 upon cycling, namely, from Ni(II) to Ni(III), thenmore » to Ni(IV). Additionally, by virtue of its surface sensitivity, soft X-ray absorption spectroscopy also reveals the electrochemically inactive Ni2+ and Mn2+ phases on the electrode surface. Our work provides the long-awaited clarification of the single-electron transfer mechanism in LiNi0.5Mn1.5O4 electrodes. Furthermore, the experimental results serve as a benchmark for further spectroscopic characterizations of Ni-based battery electrodes.« less

  17. Simultaneous removal of methylene blue and copper(II) ions by photoelectron catalytic oxidation using stannic oxide modified iron(III) oxide composite electrodes.

    PubMed

    Qi, Jinqiu; Li, Xiaochen; Zheng, Hao; Li, Peiqiang; Wang, Huying

    2015-08-15

    Stannic oxide modified Fe(III) oxide composite electrodes (SnO2/Fe2O3) were synthesized for simultaneously removing methylene blue (MB) and Cu(II) from wastewater using photoelectron catalytic oxidation (PEO). The SnO2/Fe2O3 electrodes were characterized using scanning electron microscopy (SEM), X-ray diffraction (XRD), and photoelectrochemical techniques. The removal of MB and Cu(II) by PEO using the SnO2/Fe2O3 composite electrodes was studied in terms of reaction time, electric current density, and pH of the electrolyte. The kinetics of the reactions were investigated using batch assays. The optimal reaction time, pH, and electric current density of the PEO process were determined to be 30 min, 6.0, and 10 mA/cm(2), respectively. The removal rates of MB from wastewater treated by PEO and electron catalytic oxidation process were 84.87% and 70.64%, respectively, while the recovery rates of Cu(II) were 91.75% and 96.78%, respectively. The results suggest that PEO is an effective method for the simultaneous removal of MB and Cu(II) from wastewater, and the PEO process exhibits a much higher removal rate for MB and Cu(II) compared to the electron catalytic oxidation process. Furthermore, the removal of MB was found to follow the Langmuir-Freundlich-Hinshelwood kinetic model, whereas the removal of Cu(II) fitted well to the first-order reaction model.

  18. Health care technology assessment: implications for modern medical practice. Part II. Decision making on technology adoption.

    PubMed

    Pierce, Read G; Bozic, Kevin J; Hall, Bruce Lee; Breivis, James

    2007-02-01

    Health care technology assessment, the multidisciplinary evaluation of clinical and economic aspects of technology, has come to have an increasingly important role in health policy and clinical decision-making. In Part I--Understanding Technology Adoption and Analyses--this review addressed the difficult challenges posed by assessment and provided a guide to the methodologies used. Part II presents the factors that drive the technology choices made by patients, by individual physicians, by provider groups, and by hospital administrators.

  19. Models and the dynamics of theory-building in physics. Part II-Case studies

    NASA Astrophysics Data System (ADS)

    Emch, Gérard G.

    In Part I, it was argued that models are best explained by considering the strategies from which they issue. A distinction was proposed between two classes of modeling that contribute to theory-building: H-modeling and L-modeling. Case studies are presented in this Part II to illustrate the characteristic features of these modeling strategies; examples are drawn from classical statistical mechanics and quantum physics.

  20. A Study to Determine the Optimal Frequency for Conducting Periodic Dental Examinations, Recruit Needs. Part II.

    DTIC Science & Technology

    1980-06-01

    HEALTH CARE STUDIES DIVISION REPORT #80-004 A STUDY TO DETERMINE THE OPTIMAL FREQUENCY FOR CONDUCTING PERIODIC DENTAL EXAMINATIONS RECRUIT NEEDS (Part...CONDUCTING PERIODIC DENTAL EXAMINATIONS - RECRUIT July 1979 to June 1980 NEEDS PART II G. PERFORMING ORG. REPORT NUMBER 7. AUTHOR(*) 8. CONTRACT OR GRANT...KEY WORDS (Continue an reveree side if neceeary end Identify by block number) Dental ; Recruits; Care needs; Treatment Time; Age; Oral health 2a *srhA&T

  1. Single-pulse driven, large-aperture 2×1 array plasma-electrodes optical switch for SG-II upgrading facility

    NASA Astrophysics Data System (ADS)

    Zhang, Jun; Wu, Dengsheng; Zheng, Jiangang; Zheng, Kuixing; Zhu, Qihua; Zhang, Xiongjun

    2014-12-01

    We demonstrate the design and performance of an optical switch that has been constructed for the SG-II upgrading facility. The device is a longitudinal, potassium di-hydrogen phosphate (KDP), 360 mm×360 mm aperture, and 2×1 array electro-optical switch driven by a 20 kV output switching-voltage pulse generator through two plasma electrodes produced at the rise edge of the switching-voltage pulse. The results show that the temporal responses and the spatial performance of the optical switch fulfill the operation requirements of the SG-II upgrading facility.

  2. Biology--Chemistry--Physics, Students' Guide, A Three-Year Sequence, Parts I and II.

    ERIC Educational Resources Information Center

    Scott, Arthur; And Others

    Parts I and II of the students' guide to the three-year integrated biology, chemistry, and physics course being prepared by the Portland Project Committee are contained in this guide. A committee reviewed and selected material developed by the national course improvement groups--Physical Science Study Committee, Chemical Bond Approach, Chemical…

  3. Student Performance on the NBME Part II Subtest and Subject Examination in Obstetrics-Gynecology.

    ERIC Educational Resources Information Center

    Metheny, William P.; Holzman, Gerald B.

    1988-01-01

    Comparison of the scores of 342 third-year medical students on the National Board of Medical Examiners subject examination and the Part II subtest on obstetrics-gynecology found significantly better performance on the former, suggesting a need to interpret the scores differently. (Author/MSE)

  4. Title II, Part A: Don't Scrap It, Don't Dilute It, Fix It

    ERIC Educational Resources Information Center

    Coggshall, Jane G.

    2015-01-01

    The Issue: Washington is taking a close look at Title II, Part A (Title IIA) of the Elementary and Secondary Education Act (ESEA) as Congress debates reauthorization. The program sends roughly $2.5 billion a year to all states and nearly all districts to "(1) increase student academic achievement through strategies such as improving teacher…

  5. Instructional Climates in Preschool Children Who Are At-Risk. Part II: Perceived Physical Competence

    ERIC Educational Resources Information Center

    Robinson, Leah E.; Rudisill, Mary E.; Goodway, Jacqueline D.

    2009-01-01

    In Part II of this study, we examined the effect of two 9-week instructional climates (low-autonomy [LA] and mastery motivational climate [MMC]) on perceived physical competence (PPC) in preschoolers (N = 117). Participants were randomly assigned to an LA, MMC, or comparison group. PPC was assessed by a pretest, posttest, and retention test with…

  6. Managing the care of health and the cure of disease--Part II: Integration.

    PubMed

    Glouberman, S; Mintzberg, H

    2001-01-01

    The development of appropriate levels of integration in the system of health care and disease cure will require stronger collective cultures and enhanced communication among the key actors. Part II of this paper uses this line of argument to reframe four major issues in this system: coordination of acute cure and of community care, and collaboration in institutions and in the system at large.

  7. Student Performance on the NBME Part II Subtest and Subject Examination in Obstetrics-Gynecology.

    ERIC Educational Resources Information Center

    Metheny, William P.; Holzman, Gerald B.

    1988-01-01

    Comparison of the scores of 342 third-year medical students on the National Board of Medical Examiners subject examination and the Part II subtest on obstetrics-gynecology found significantly better performance on the former, suggesting a need to interpret the scores differently. (Author/MSE)

  8. 48 CFR 15.204-3 - Part II-Contract Clauses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Part II-Contract Clauses. 15.204-3 Section 15.204-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... uniform contract format. An index may be inserted if this section's format is particularly complex. ...

  9. 48 CFR 15.204-3 - Part II-Contract Clauses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Part II-Contract Clauses. 15.204-3 Section 15.204-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... uniform contract format. An index may be inserted if this section's format is particularly complex. ...

  10. Instructional Climates in Preschool Children Who Are At-Risk. Part II: Perceived Physical Competence

    ERIC Educational Resources Information Center

    Robinson, Leah E.; Rudisill, Mary E.; Goodway, Jacqueline D.

    2009-01-01

    In Part II of this study, we examined the effect of two 9-week instructional climates (low-autonomy [LA] and mastery motivational climate [MMC]) on perceived physical competence (PPC) in preschoolers (N = 117). Participants were randomly assigned to an LA, MMC, or comparison group. PPC was assessed by a pretest, posttest, and retention test with…

  11. Thermoelectric Properties of Pristine and Doped Graphene Nanosheets and Graphene Nanoribbons: Part II

    NASA Astrophysics Data System (ADS)

    Muley, Sarang V.; Ravindra, N. M.

    2016-06-01

    In Part II of this study, approaches to improve the thermoelectric figure of merit ( ZT) of graphene nanosheets and nanoribbons is discussed. The presence of vacancies in graphene is found to increase the ZT of zigzag graphene nanoribbons significantly. Graphene can be a promising material with much better thermoelectric performance than conventional thermoelectrics.

  12. Coupled ADCIRC Model Systems Part I: HYCOM/ADCIRC Part II: HLRDHM/SWAN/ADCIRC

    NASA Astrophysics Data System (ADS)

    Kolar, R. L.; Dresback, K. M.; Blain, C. A.; Luettich, R.; Cooten, S. V.; Gourley, J. J.; Hong, Y.; Cambazoglu, M. K.; Szpilka, C.; Nemunaitis, K.; Szpilka, A.

    2010-12-01

    ADCIRC (Advanced CIRCulation) is a 2D/3D hydrodynamic model based on the St. Venant equations subject to the standard Boussinesq approximation; applications over its 20-year history range from predicting the effects of coastal dredging to developing a tidal database to estimating the extent of hurricane storm surge inundation. In order to extend the capabilities of ADCIRC and improve its predictive ability in these and other applications, the development team has been coupling ADCIRC to other models, either dynamically or one-way, depending on the physics of the problem. Herein, we discuss two such coupled systems. In the first, 3D baroclinic ADCIRC is coupled to the regional HYCOM model. The work is motivated by our interest in using an unstructured, high resolution, near-coastal model to capture the complex fluid dynamics that occurs in topographically-challenging regions. Specifically, this presentation will summarize the procedures as applied to the coupled HYCOM/ADCIRC system in the Northern Gulf of Mexico. In the second part of the presentation, 2D ADCIRC is dynamically coupled to the SWAN wave model, and the HLRDHM hydrologic model provides fresh water inflows for major rivers and tributaries. The objective of this work is to generate a more holistic description of coastal flooding due to the combined effects of hurricane storm surge and upland runoff. Furthermore, it addresses NOAA’s call for a “total water level” prediction system. Initially, it is being tested on the Tar-Neuse-Pamlico Sound basin in North Carolina; preliminary results from Hurricane Isabel hindcasts will be shown. Hurricane Isabel significant wave heights (m) and wind vectors (m/s) at 1600 UTC 18 September 2003 for the coastal regions of North Carolina using the coupled HLRDHM/SWAN/ADCIRC system.

  13. The Basket Method for Selecting Balanced Samples. Part II. Applications to Price Estimation.

    DTIC Science & Technology

    1981-12-01

    AD-AI12 949 CLEMSON UNIV SC OEPT OF MATHEMATICAL SCIENCES F/B 12/1 THE BASKET METHOD FOR SELECTING BALANCED SAMPLES. PART 11. APPL-ETC(U) DEC SI K T...1111󈧝 1.4 1.6 MICROCOPY RESOLUTION TEST CHARTNN’( 4~ THE BASKET METHOD FOR SELECTING BALANCED SAMPLES - PART II: APPLICATIONS TO PRICE ESTIMATION * K...for Selecting Balanced Samples Part I: Applications to Price Estimation AB9TRACT The "Basket Method" of sampling, a tool designed to achieve

  14. Uphill transport membrane electrodes

    SciTech Connect

    Uto, M.; Yoshida, H.; Sugawara, M.; Umezawa, Y.

    1986-07-01

    A new membrane electrode was constructed in which carrier-mediated uphill transport of analytes is incorporated. The electrode can boost selectively virtual concentration of specific analytes by uphill transport against their concentration gradient across a built-in liquid membrane into its inner filling solution, whose volume is purposely made very small. Cd(II), UO/sub 2//sup 2 +/, and Cu(II) ion uphill transport membrane electrodes constructed here as illustrative examples utilize three different types of input energies, i.e., complexation, concentration gradient, and redox, respectively, for uphill transport of each analyte. Voltammetric detections were demonstrated for Cd(II) and UO/sub 2//sup 2 +/ ion uphill transport electrodes, and a potentiometric detection for a Cu(II) ion uphill transport membrane electrode is also described in terms of fundamental behaviors and a possible use for a new type of electrochemical sensor.

  15. Flexible retinal electrode array

    DOEpatents

    Okandan, Murat; Wessendorf, Kurt O.; Christenson, Todd R.

    2006-10-24

    An electrode array which has applications for neural stimulation and sensing. The electrode array can include a large number of electrodes each of which is flexibly attached to a common substrate using a plurality of springs to allow the electrodes to move independently. The electrode array can be formed from a combination of bulk and surface micromachining, with electrode tips that can include an electroplated metal (e.g. platinum, iridium, gold or titanium) or a metal oxide (e.g. iridium oxide) for biocompatibility. The electrode array can be used to form a part of a neural prosthesis, and is particularly well adapted for use in an implantable retinal prosthesis where the electrodes can be tailored to provide a uniform gentle contact pressure with optional sensing of this contact pressure at one or more of the electrodes.

  16. Micromachined electrode array

    DOEpatents

    Okandan, Murat; Wessendorf, Kurt O.

    2007-12-11

    An electrode array is disclosed which has applications for neural stimulation and sensing. The electrode array, in certain embodiments, can include a plurality of electrodes each of which is flexibly attached to a common substrate using a plurality of springs to allow the electrodes to move independently. In other embodiments of the electrode array, the electrodes can be fixed to the substrate. The electrode array can be formed from a combination of bulk and surface micromachining, and can include electrode tips having an electroplated metal (e.g. platinum, iridium, gold or titanium) or a metal oxide (e.g. iridium oxide) for biocompatibility. The electrode array can be used to form a part of a neural prosthesis, and is particularly well adapted for use in an implantable retinal prosthesis.

  17. In vitro performance of Class I and II composite restorations: a literature review on nondestructive laboratory trials--part II.

    PubMed

    Dietschi, D; Argente, A; Krejci, I; Mandikos, M

    2013-01-01

    A literature review was conducted on adhesive Class I and II restorations and nondestructive in vitro tests using the PubMed/Medline database for the 1995-2010 period. The first part of this review has presented and critically appraised selected literature dealing with the quality and in vitro behavior of adhesive Class II restorations using photoelasticity, finite element analysis, and microleakage study protocols. This second part reviews additional parameters, which are deformation and fracture resistance to cyclic loading, shrinkage stress and tooth deformation following restoration placement, bond strength (microtensile, tensile, and shear tests), and marginal and internal adaptation. In addition, a "relevance score" has been proposed that aims to classify the different study protocols according, firstly, to the resulting quality, quantity, and consistency of the evidence and then, secondly, to their potential clinical relevance, as estimated by their ability to simulate oral and biomechanical strains. The highest clinical relevance was attributed to marginal and internal adaptation studies, following cyclic loading in a moist environement. However, a combination of in vitro protocols will have an even greater predictive potential and has to be considered as a crucial preclinical research approach with which to investigate the numerous restorative configurations that cannot be efficiently and rapidly tested in vivo.

  18. An electrochemiluminescent biosensor for glucose based on the electrochemiluminescence of luminol on the nafion/glucose oxidase/poly(nickel(II)tetrasulfophthalocyanine)/multi-walled carbon nanotubes modified electrode.

    PubMed

    Qiu, Bin; Lin, Zhenyu; Wang, Jian; Chen, Zhihuang; Chen, Jinhua; Chen, Guonan

    2009-04-15

    A poly(nickel(II) tetrasulfophthalocyanine)/multi-walled carbon nanotubes composite modified electrode (polyNiTSPc/MWNTs) was fabricated by electropolymerization of NiTSPc on MWNTs-modified glassy carbon electrode (GCE). The modified electrode was found to be able to greatly improve the emission of luminol electrochemiluminescence (ECL) in a solution containing hydrogen peroxide. Glucose oxidase (GOD) was immobilized on the surface of polyNiTSPc/MWNTs modified GC electrode by Nafion to establish an ECL glucose sensor. Under the optimum conditions, the linear response range of glucose was 1.0x10(-6) to 1.0x10(-4) mol L(-1) with a detection limit of 8.0x10(-8) mol L(-1) (defined as the concentration that could be detected at the signal-to-noise ratio of 3). The ECL sensor showed an outstanding well reproducibility and long-term stability. The established method has been applied to determine the glucose concentrations in real serum samples with satisfactory results.

  19. Cooperative cathode electrode and in situ deposited copper for subsequent enhanced Cd(II) removal and hydrogen evolution in bioelectrochemical systems.

    PubMed

    Wang, Qiang; Huang, Liping; Pan, Yuzhen; Zhou, Peng; Quan, Xie; Logan, Bruce E; Chen, Hongbo

    2016-01-01

    Bioelectrochemical systems (BESs) were first operated in microbial fuel cell mode for recovering Cu(II), and then shifted to microbial electrolysis cells for Cd(II) reduction on the same cathodes of titanium sheet (TS), nickel foam (NF) or carbon cloth (CC). Cu(II) reduction was similar to all materials (4.79-4.88mg/Lh) whereas CC exhibited the best Cd(II) reduction (5.86±0.25mg/Lh) and hydrogen evolution (0.35±0.07m(3)/m(3)d), followed by TS (5.27±0.43mg/Lh and 0.15±0.02m(3)/m(3)d) and NF (4.96±0.48mg/Lh and 0.80±0.07m(3)/m(3)d). These values were higher than no copper controls by factors of 2.0 and 5.0 (TS), 4.2 and 2.0 (NF), and 1.8 and 7.0 (CC). These results demonstrated cooperative cathode electrode and in situ deposited copper for subsequent enhanced Cd(II) reduction and hydrogen production in BESs, providing an alternative approach for efficiently remediating Cu(II) and Cd(II) co-contamination with simultaneous hydrogen production. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Confirming the validity of Part II of the National Board Dental Examinations: a practice analysis.

    PubMed

    Kramer, Gene A; Neumann, Laura M

    2003-12-01

    Successful completion of Part II of the National Board Dental Examinations is a part of the licensure process for dentists. Good testing practice requires that the content of a high stakes examination like Part II be based on a strong relationship between the content and the judgments of practicing dentists on what is important to their practice of dentistry. In an effort to demonstrate this relationship for Part II, the Joint Commission conducted a practice analysis, which involved a two-dimensional model. The sixty-three Competencies of the New Dentist, developed and promulgated by the American Dental Education Association, were used for one dimension, and the current content specifications were used for the other. A survey of 520 practicing dentists was conducted to determine the importance of each of the competencies for patient care. These dentists were recent graduates of accredited programs and passed Part II three to five years prior to the conduct of the practice analysis. The survey directed the respondents to rate the importance of the competencies on a scale from 1 to 5. Of the 520 in the sample, 244 dentists responded. The reliability index was above 0.90. The importance rating for each competency was translated into the associated number of items. The number of items devoted to each competency was allocated to the current content elements that are related to the knowledge and problem-solving skills that support each competency. The findings specified revisions in the relative number of items dedicated to the various elements in the specifications. These findings indicate that the items on the examination under the current distribution adequately reflected practice. In general, there were relatively small changes in the content specifications. The total number of changes in items was forty-eight, which represents changes in slightly less than 10 percent of the overall number of items.

  1. Part I. The fire properties of polymer clay nanocomposites. Part II. Thermal rearrangement of donor-acceptor substituted cyclopropanes

    NASA Astrophysics Data System (ADS)

    Su, Shengpei

    2003-08-01

    This work consists of two parts. Part I, which includes chapter 1--5, is focused on the fire properties of nanocomposites while part II deals with thermal rearrangement of the donor-acceptor cyclopropanes. In chapter 1 of the first part an introduction to the preparation of polymer-clay nanocomposites is provided along with their application to fire retardancy. Chapter 2 details the exfoliation process of clay using in situ polymerization; the results show that the exfoliation process is related to the monomer, the modified clay and the initiator. Chapter 3 concentrates on the preparation of nanocomposites by melt blending with polymer modified clays. Three different polymer modified clays (PS, PMMA and PBD modified clay) and six polymers (PS, HIPS, ABS, PMMA, PP and PE) are reported. The morphology, thermal stability, fire behavior and mechanical properties were studied. This research shows that the exfoliation process by melt blending is controlled by the types of interactions between the various polymers, the silicate surfaces and the organic modifier. The combination of polar polymer matrix and non-polar polymer modified clay with large d-spacing will be more likely to give the exfoliated nanocomposites. TGA-FTIR results show that the mechanism of degradation of polystyrene is changed in the presence of the clay. In order to better understand the effects of the organic modifier, PS surfactants with five different pendant groups, dimethylhexadecylamine, trimethylamine, dimethylbenzylamine, 1,2-dimethylimidizole and triphenylphosphine, were used and the results show that the degradation depends upon the pendant. Chapter 5 provides some suggestions for future work based upon this work. The synthesis of several new and previously reported donor-acceptor cyclopropanes is reported in part II. The study shows that the facility of the donor-acceptor cyclopropane ring cleavage is strongly influenced by the kind of activating substitutes on the cyclopropane ring, and the

  2. Percutaneous Coronary Intervention or Coronary Artery Bypass Grafting: Intervention in Older Persons with Acute Coronary Syndrome—Part II

    PubMed Central

    Sheridan, Brett C.; Stearns, Sally C.; Massing, Mark W.; Stouffer, George A.; D’Arcy, Laura P.; Carey, Timothy S.

    2009-01-01

    This is Part II of a two-part article on treatment of acute coronary syndrome in the older population. Part I (published in the October issue of Clinical Geriatrics) analyzed the differential utilization of invasive therapies with respect to age and heart disease. Part II summarizes information from the literature on acute coronary syndrome outcomes from invasive treatments (percutaneous coronary interventions or coronary artery bypass grafting) among older persons. PMID:20607092

  3. High selective SiO2-Al2O3 mixed-oxide modified carbon paste electrode for anodic stripping voltammetric determination of Pb(II).

    PubMed

    Ghiaci, M; Rezaei, B; Kalbasi, R J

    2007-08-15

    The main purpose of this study is to develop an inexpensive, simple, selective and especially highly selective modified mixed-oxide carbon paste electrode (CPE) for voltammetric determination of Pb(II). For the preliminary screening purpose, the catalyst was prepared by modification of SiO(2)-Al(2)O(3) mixed-oxide and characterized by TG, CHN elemental analysis and FTIR spectroscopy. Using cyclic voltammetry the electroanalytical characteristics of the catalyst have been determined, and consequently the modified mixed-oxide carbon paste electrode was constructed and applied for determination of Pb(II). The electroanalytical procedure for determination of the Pb(II) comprises two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse anodic stripping voltammetry. During the preconcentration step, Pb(II) was accumulated on the surface of the modifier by the formation of a complex with the nitrogen atoms of the pyridyl groups in the modifier. The peak currents increases linearly with Pb(II) concentration over the range of 2.0 x 10(-9) to 5.2 x 10(-5)mol L(-1) (r(2)=0.9995). The detection limit (three times signal-to-noise) was found to be 1.07 x 10(-9)mol L(-1) Pb(II). The chemical and instrumental parameters have been optimized and the effect of the interferences has been determined. The Proposed method was used for determination of lead ion in the real samples.

  4. Simultaneous determination of Mn(II), Cu(II) and Fe(III) as 2-(5'-bromo-2'-pyridylazo)-5-diethylaminophenol complexes by adsorptive cathodic stripping voltammetry at a carbon paste electrode.

    PubMed

    Ghoneim, Enass M

    2010-07-15

    A simple and precise square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV) method has been described for simultaneous determination of Mn(II), Cu(II) and Fe(III) in water samples using a carbon paste electrode. In 0.1 mol L(-1) acetate buffer (pH 5) containing 50 micromol L(-1) of 2-(5'-bromo-2'-pyridylazo)-5-diethylaminophenol (5-Br-PADAP), Mn(II), Cu(II) and Fe(III) were simultaneously determined as metal-complexes with 5-Br-PADAP following preconcentration onto the carbon paste electrode by adsorptive accumulation at +1.0V (vs. Ag/AgCl/3M KCl). Insignificant interference from various cations (K(+), Na(+), Mg(2+), Ca(2+), Al(3+), Bi(3+), Sb(3+), Se(4+), Zn(2+), Ni(2+), Co(2+), Cd(2+), Pb(2+), V(5+), Ti(4+) and NH(4)(+)), anions (HCO(3)(-), Cl(-), NO(3-), SO(4)(2-) and PO(4)(3-)) and ascorbic acid was noticed. Limits of detection of 0.066, 0.108 and 0.093 microg L(-1) and limits of quantitation of 0.22, 0.36 and 0.31 microg L(-1) Mn(II), Cu(II) and Fe(III), respectively, were achieved by the described method. The described stripping voltammetry method was successfully applied for simultaneous determination of Mn(II), Cu(II) and Fe(III) in ground, tap and bottled natural water samples. Copyright 2010 Elsevier B.V. All rights reserved.

  5. An International Round-Robin Study, Part II: Thermal Diffusivity, Specific Heat and Thermal Conductivity

    SciTech Connect

    Wang, Hsin; Porter, Wallace D; Bottner, Harold; Konig, Jan; Chen, Lidong; Bai, Shengqiang; Tritt, Terry M.; Mayolett, Alex; Senawiratne, Jayantha; Smith, Charlene; Harris, Fred; Gilbert, Partricia; Sharp, J; Lo, Jason; Keinke, Holger; Kiss, Laszlo I.

    2013-01-01

    For bulk thermoelectrics, figure-of-merit, ZT, still needs to improve from the current value of 1.0 - 1.5 to above 2 to be competitive to other alternative technologies. In recent years, the most significant improvements in ZT were mainly due to successful reduction of thermal conductivity. However, thermal conductivity cannot be measured directly at high temperatures. The combined measurements of thermal diffusivity and specific heat and density are required. It has been shown that thermal conductivity is the property with the greatest uncertainty and has a direct influence on the accuracy of the figure of merit. The International Energy Agency (IEA) group under the implementing agreement for Advanced Materials for Transportation (AMT) has conducted two international round-robins since 2009. This paper is Part II of the international round-robin testing of transport properties of bulk bismuth telluride. The main focuses in Part II are on thermal diffusivity, specific heat and thermal conductivity.

  6. Electrocatalytic behaviour of carbon paste electrode modified with iron(II) phthalocyanine (FePc) nanoparticles towards the detection of amitrole.

    PubMed

    Siswana, Msimelelo; Ozoemena, Kenneth I; Nyokong, Tebello

    2006-07-15

    This paper describes the construction of a carbon paste electrode (CPE) impregnated with nanoparticles of iron(II) phthalocyanine (nanoFePc). The new electrode (nanoFePc-CPE) revealed interesting electrocatalytic behaviour towards amitrole; pure catalytic diffusion-controlled process, with high Tafel slope (235 mV/decade) suggesting strong binding of amitrole with nanoFePc catalyst. The effects of catalyst loading, varying pH and electrolytes were studied. The mechanism for the interaction of amitrole with the nanoFePc is proposed to involve the Fe((III))Pc/Fe((II))Pc redox process. Using chronoamperometry (E=+0.42V versus Ag/AgCl) technique, the sensor was reliably employed for amitrole assay at pH 12.0 phosphate buffer (with sodium sulphate as the supporting electrolyte) for up to 12 nM amitrole with excellent sensitivity (ca. 3.44 microA/nM) and low detection limit (3.62+/-0.11 nM, i.e. 0.305 microgL(-1) using the Y(B)+3(sigmaB) criterion and 0.85+/-0.03 nM, i.e. 70 ng/L with the Y(B)+2(sigmaB) criterion) as well as satisfactory amperometric selectivity coefficient (K(amp) approximately equal to 7.4 x 10(-4) for ammonium thiocyanate, a component of many amitrole herbicides, and 3.2 x 10(-3) for asulam pesticide). The surface of the electrode can easily be regenerated by simple polishing on an alumina paper, obtaining a fresh surface ready for use in a new assay. The proposed electrode was successfully applied in the quantification of amitrole in its commercial formulation as well as in tap water samples.

  7. Modeling and technical use of gas evolving electrodes. Part 2: Modeling of gas-evolving electrolyzers with free electrolyte circulation

    NASA Technical Reports Server (NTRS)

    Schleiff, M.; Thiele, W.; Matschiner, H.

    1983-01-01

    In an electrochemical reactor with gas-evolving electrodes, the transporting action of the gas bubbles can be used to move the electrolyte in a cycle flow, when the structure of the flow channels is suitable. For an electrolysis cell with such a circulation system a mathematic model was set up and evaluated. It is shown that in this manner, a rapid flow through the electrode gap can be achieved without additional energy consumption, in addition to a low gas fraction and a low cell voltage. The cell voltage and the attainable cycle spread are investigated as a function of the geometric parameters for their optimum values.

  8. Paleotectonic investigations of the Mississippian System in the United States: Parts I and II

    USGS Publications Warehouse

    Craig, Lawrence C.; Connor, Carol Waite; Others,

    1979-01-01

    This professional paper is the fifth in a series of paleotectonic studies each covering a geologic system in the conterminous United States. Part I provides a region-by-region discussion of data concerning the Mississippian System and an explanation and documentation for the maps and sections contained in part III. Part II of the paper provides a summary of the Mississippian System, presents interregional interpretations permitted by this study, and includes sections on notable features of the system. The maps contained in the separate case as part III may be divided into two groups: (1) a sequence of factual or basic maps that shows, with a minimum of interpretation, the Mississippian System as it occurs today, and (2) interpretive maps that attempt a reasonable reconstruction of the original extent of the system, its tectonics, environment, and geography.

  9. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride...

  10. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride...

  11. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride...

  12. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride...

  13. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride...

  14. The structure and interpretation of cosmology: Part II. The concept of creation in inflation and quantum cosmology

    NASA Astrophysics Data System (ADS)

    McCabe, Gordon

    The purpose of the paper, of which this is part II, is to review, clarify, and critically analyse modern mathematical cosmology. The emphasis is upon mathematical objects and structures, rather than numerical computations. Part II provides a critical analysis of inflationary cosmology and quantum cosmology, with particular attention to the claims made that these theories can explain the creation of the universe.

  15. Thermoelectric Generators for Automotive Waste Heat Recovery Systems Part II: Parametric Evaluation and Topological Studies

    NASA Astrophysics Data System (ADS)

    Kumar, Sumeet; Heister, Stephen D.; Xu, Xianfan; Salvador, James R.; Meisner, Gregory P.

    2013-06-01

    A comprehensive numerical model has been proposed to model thermoelectric generators (TEGs) for automotive waste heat recovery. Details of the model and results from the analysis of General Motors' prototype TEG were described in part I of the study. In part II of this study, parametric evaluations are considered to assess the influence of heat exchanger, geometry, and thermoelectric module configurations to achieve optimization of the baseline model. The computational tool is also adapted to model other topologies such as transverse and circular configurations (hexagonal and cylindrical) maintaining the same volume as the baseline TEG. Performance analysis of these different topologies and parameters is presented and compared with the baseline design.

  16. DEUTERIUM, TRITIUM, AND HELIUM DESORPTION FROM AGED TITANIUM TRITIDES. PART II.

    SciTech Connect

    Shanahan, K; Jeffrey Holder, J

    2006-08-17

    Six new samples of tritium-aged bulk titanium have been examined by thermal desorption and isotope exchange chemistry. The discovery of a lower temperature hydrogen desorption state in these materials, previously reported, has been confirmed in one of the new samples. The helium release of the samples shows the more severe effects obtained from longer aging periods, i.e. higher initial He/M ratios. Several of the more aged samples were spontaneously releasing helium. Part I discussed the new results on the new lower temperature hydrogen desorption state found in one more extensively studied sample. Part II will discuss the hydrogen/helium release behavior of the remaining samples.

  17. Patient safety in procedural dermatology: Part II. Safety related to cosmetic procedures.

    PubMed

    Lolis, Margarita; Dunbar, Scott W; Goldberg, David J; Hansen, Timothy J; MacFarlane, Deborah F

    2015-07-01

    Cosmetic procedures are growing in popularity and are associated with unique risks. Considering potential complications and prioritizing patient safety will help practitioners improve outcomes of elective procedures. In part II of this continuing medical education article, we provide a comprehensive review of patient safety in cosmetic procedures, including medical and legal issues surrounding the supervision and training of physician extenders. Copyright © 2014 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Predicting performance on the Medical Council of Canada Qualifying Exam Part II.

    PubMed

    Woloschuk, Wayne; McLaughlin, Kevin; Wright, Bruce

    2013-01-01

    Being able to predict which residents will likely be unsuccessful on high-stakes exams would allow residency programs to provide early intervention. To determine whether measures of clinical performance in clerkship (in-training evaluation reports) and first year of residency (program director ratings) predict pass-fail performance on the Medical Council of Canada Qualifying Exam Part II (MCCQE Part II). Residency program directors assessed the performance of our medical school graduates (Classes 2004-2007) at the end of the 1st postgraduate year. We subsequently collected clerkship in-training evaluation reports for these graduates. Using a neutral third party and unique codes, an anonymous dataset containing clerkship, residency, and MCCQE Part II performance scores was created for our use. Data were analyzed using descriptive statistics, correlations, receiver operating characteristics, and the Youdin index. Regression was also performed to further study the relationship among the variables. Complete data were available for 78.6% of the graduates. Of these participants, 94% passed the licensing exam on their first attempt. Receiver operating characteristics revealed that the area under the curve for clerkship in-training evaluation reports was 0.67 (p<.05) and 0.66 (p<.05) for residency program directors assessments. Corresponding Youdin indices for in-training evaluation reports and residency program director assessments were 0.30 and 0.23, respectively. Although clerkship in-training evaluation reports and residency program director ratings are significant predictors of pass-fail performance on the MCCQE Part II, the effectiveness of each one to predict pass-fail performance was relatively small. Reasons for these findings are discussed.

  19. Recruitment Early Warning System and Accession Contingency Planning Process. Phase II. Part 1.

    DTIC Science & Technology

    1984-11-01

    RD-A154 613 RECRUITMENT EARLY WARNING SYSTEM AND ACCESSION i/7 CONTINGENCY PLANNING PROCE..(U) ECONOMIC RESEARCH LAB INC RESTON YA L GOLDBERG ET AL...11 TITLE (include Security Classification) Recruitment Early Warning System and Accession Contingency Planning Process Phase II, Part 1 Final Report...GROUP Early Warning System, Forecasting, Manpower Planning LV &V WA&Vm 19. ABSTRACT (Continue on reverse if necessary and identify by block ny.1ber

  20. Alchemical poetry in medieval and early modern Europe: a preliminary survey and synthesis. Part II - Synthesis.

    PubMed

    Kahn, Didier

    2011-03-01

    This article provides a preliminary description of medieval and early modern alchemical poetry composed in Latin and in the principal vernacular languages of western Europe. It aims to distinguish the various genres in which this poetry flourished, and to identify the most representative aspects of each cultural epoch by considering the medieval and early modern periods in turn. Such a distinction (always somewhat artificial) between two broad historical periods may be justified by the appearance of new cultural phenomena that profoundly modified the character of early modern alchemical poetry: the ever-increasing importance of the prisca theologia, the alchemical interpretation of ancient mythology, and the rise of neo-Latin humanist poetry. Although early modern alchemy was marked by the appearance of new doctrines (notably the alchemical spiritus mundi and Paracelsianism), alchemical poetry was only superficially modified by criteria of a scientific nature, which therefore appear to be of lesser importance. This study falls into two parts. Part I provides a descriptive survey of extant poetry, and in Part II the results of the survey are analysed in order to highlight such distinctive features as the function of alchemical poetry, the influence of the book market on its evolution, its doctrinal content, and the question of whether any theory of alchemical poetry ever emerged. Part II is accompanied by an index of the authors and works cited in both parts.

  1. Can focusing on UPDRS Part II make assessments of Parkinson disease progression more efficient?

    PubMed

    Sampaio, Cristina

    2009-03-01

    Harrison et al. have attempted to validate Part II of the Unified Parkinson's Disease Rating Scale (UPDRS II) as a medication-independent measure of disease progression. The authors collected cross-sectional data from a cohort of 888 patients with idiopathic Parkinson disease, and they found a robust association between UPDRS II scores and disease duration. Other variables considered were the patients' levodopa status, age at disease onset, and scores on UPDRS I, II and III. The results suggest that a single UPDRS II measurement might be a good indicator of progression at a given time point, irrespective of the current disease-related circumstances. This concept is attractive in its simplicity and patient-centeredness. However, this evidence came from a single-center, retrospective study, the statistical model was constructed using a nonvalidated surrogate as an independent variable, and no external replication was conducted. Until further confirmation, therefore, Harrison et al.'s proposal can only be considered to be a working hypothesis.

  2. Validity of NBME Parts I and II for the Selection of Residents: The Case of Orthopaedic Surgery.

    ERIC Educational Resources Information Center

    Case, Susan M.

    The predictive validity of scores on the National Board of Medical Examiners (NBME) Part I and Part II examinations for the selection of residents in orthopaedic surgery was investigated. Use of NBME scores has been criticized because of the time lag between taking Part I and entering residency and because Part I content is not directly linked to…

  3. Covalent attachment of diphosphine ligands to glassy carbon electrodes via Cu-catalyzed alkyne-azide cycloaddition. Metallation with Ni(II).

    PubMed

    Das, Atanu K; Engelhard, Mark H; Lense, Sheri; Roberts, John A S; Bullock, R Morris

    2015-07-21

    Covalent tethering of P(Ph)2N(C6H4C≡CH)2 ligands (P(Ph)2N(C6H4C≡CH)2 = 1,5-di-(4-ethynylphenyl)-3,7-diphenyl-1,5-diaza-3,7-diphosphacyclooctane) to planar, azide-terminated glassy carbon electrode surfaces has been accomplished using a Cu(I)-catalyzed alkyne-azide cycloaddition (CuAAC) coupling reaction, using a BH3←P protection-deprotection strategy. Deprotected, surface-confined ligands were metallated using [Ni(II)(MeCN)6](BF4)2. X-ray photoelectron spectroscopic measurements demonstrate that metallation introduced 1.3 equivalents Ni(II) per diphosphine onto the electrode surface. Exposure of the surface to a second diphosphine ligand, P(Ph)2N(Ph)2, resulted in the removal of Ni from the surface. Protection, coupling, deprotection, and metallation conditions were optimized using solution-phase model systems, with benzyl azide as a model for the azide-terminated carbon surface; these reactions generate a [Ni(II)(diphosphine)2](2+) complex.

  4. A novel voltammetric sensor for sensitive detection of mercury(II) ions using glassy carbon electrode modified with graphene-based ion imprinted polymer.

    PubMed

    Ghanei-Motlagh, Masoud; Taher, Mohammad Ali; Heydari, Abolfazl; Ghanei-Motlagh, Reza; Gupta, Vinod K

    2016-06-01

    In this paper, a novel strategy was proposed to prepare ion-imprinted polymer (IIP) on the surface of reduced graphene oxide (RGO). Polymerization was performed using methacrylic acid (MAA) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, 2,2'-((9E,10E)-1,4-dihydroxyanthracene-9,10-diylidene) bis(hydrazine-1-carbothioamide) (DDBHCT) as the chelating agent and ammonium persulfate (APS) as initiator, via surface imprinted technique. The RGO-IIP was characterized by means of Fourier transform infrared spectroscopy (FT-IR), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) and thermogravimetric analysis (TGA). The electrochemical procedure was based on the accumulation of Hg(II) ions at the surface of a modified glassy carbon electrode (GCE) with RGO-IIP. The prepared RGO-IIP sensor has higher voltammetric response compared to the non-imprinted polymer (NIP), traditional IIP and RGO. The RGO-IIP modified electrode exhibited a linear relationship toward Hg(II) concentrations ranging from 0.07 to 80 μg L(-1). The limit of detection (LOD) was found to be 0.02 μg L(-1) (S/N=3), below the guideline value from the World Health Organization (WHO). The applicability of the proposed electrochemical sensor to determination of mercury(II) ions in different water samples was reported.

  5. Voltammetric detection of lead(II) and mercury(II) using a carbon paste electrode modified with thiol self-assembled monolayer on mesoporous silica (SAMMS).

    PubMed

    Yantasee, Wassana; Lin, Yuehe; Zemanian, Thomas S; Fryxell, Glen E

    2003-05-01

    The anodic stripping voltammetry at a carbon paste electrode modified with thiol terminated self-assembled monolayer on mesoporous silica (SH-SAMMS) provides a new sensor for simultaneous detection of lead (Pb2+) and mercury (Hg2+) in aqueous solutions. The overall analysis involved a two-step procedure: an accumulation step at open circuit, followed by medium exchange to a pure electrolyte solution for the stripping analysis. Factors affecting the performance of the SH-SAMMS modified electrodes were investigated, including electrode activation and regeneration, electrode composition, preconcentration time, electrolysis time, and composition of electrolysis and stripping media. The most sensitive and reliable electrode contained 20% SH-SAMMS and 80% carbon paste. The optimal operating conditions were a sequence with a 2 min preconcentration period, then a 60 s electrolysis period of the preconcentrated species in 0.2 M nitric acid, followed by square wave anodic stripping voltammetry from -1.0 V to 0.6 V in 0.2 M nitric acid. The areas of the peak responses were linear with respect to metal ion concentrations in the ranges of 10-1500 ppb Pb2+ and 20-1600 ppb Hg2+. The detection limits for Pb2+ and Hg2+ were 0.5 ppb Pb2+ and 3 ppb Hg2+ after a 20 min preconcentration period.

  6. Application of artificial neural network to simultaneous potentiometric determination of silver(I), mercury(II) and copper(II) ions by an unmodified carbon paste electrode.

    PubMed

    Shamsipur, Mojtaba; Tashkhourian, Javad; Hemmateenejad, Bahram; Sharghi, Hashem

    2004-10-20

    The response characteristics and selectivity coefficients of an unmodified carbon paste electrode (CPEs) towards Ag(+), Cu(2+) and Hg(2+) were evaluated. The electrode was used as an indicator electrode for the simultaneous determination of the three metal ions in their mixtures via potentiometric titration with a standard thiocyanate solution. A three-layered feed-forward artificial neural network (ANN) trained by back-propagation learning algorithm was used to model the complex non-linear relationship between the concentration of silver, copper and mercury in their different mixtures and the potential of solution at different volumes of the added titrant. The network architecture and parameters were optimized to give low prediction errors. The optimized networks were able to precisely predict the concentrations of the three cations in synthetic mixtures.

  7. A Solid-Contact Ion Selective Electrode for Copper(II) Using a Succinimide Derivative as Ionophore

    PubMed Central

    Tutulea-Anastasiu, Mihaela Dana; Wilson, Deivy; del Valle, Manel; Schreiner, Cristina Mihaela; Cretescu, Igor

    2013-01-01

    All-solid-state sensors with polyvinyl chloride (PVC)-based membranes using off-the-shelf N-hydroxysuccinimide (NHS) and succinimide (Succ) ionophores were prepared using DOP (dioctyl phthalate) and NPOE (ortho-nitrophenyloctyl ether) as plasticizers. Good responses were obtained when NHS was used. The potentiometric response of the proposed electrode is independent of pH over the range 2–6. The electrode shows a fast response time of 0.25 s. The electrode exhibits a Super-Nernstian response, with 37.5 mV/decade, with a potentiometric detection limit of 4.4 μM. The proposed sensor revealed good selectivity towards a group of transition metal ions. PMID:23549362

  8. Subseabed disposal program annual report, January-December 1980. Volume II. Appendices (principal investigator progress reports). Part 1

    SciTech Connect

    Hinga, K.R.

    1981-07-01

    Volume II of the sixth annual report describing the progress and evaluating the status of the Subseabed Disposal Program contains the appendices referred to in Volume I, Summary and Status. Because of the length of Volume II, it has been split into two parts for publication purposes. Part 1 contains Appendices A-Q; Part 2 contains Appendices R-MM. Separate abstracts have been prepared for each appendix for inclusion in the Energy Data Base.

  9. Investigation of Cu(II) Binding to Bovine Serum Albumin by Potentiometry with an Ion Selective Electrode

    ERIC Educational Resources Information Center

    Jie Liu

    2004-01-01

    A laboratory project that investigates Cu(II) bind to bovine serum albumin (BSA) in an aqueous solution is developed to assist undergraduate students in gaining better understanding of the interaction of ligands with biological macromolecule. Thus, students are introduced to investigation of Cu(II) binding to BSA by potentiometry with the Cu(II)…

  10. Investigation of Cu(II) Binding to Bovine Serum Albumin by Potentiometry with an Ion Selective Electrode

    ERIC Educational Resources Information Center

    Jie Liu

    2004-01-01

    A laboratory project that investigates Cu(II) bind to bovine serum albumin (BSA) in an aqueous solution is developed to assist undergraduate students in gaining better understanding of the interaction of ligands with biological macromolecule. Thus, students are introduced to investigation of Cu(II) binding to BSA by potentiometry with the Cu(II)…

  11. A Lagrangian variational formulation for nonequilibrium thermodynamics. Part II: Continuum systems

    NASA Astrophysics Data System (ADS)

    Gay-Balmaz, François; Yoshimura, Hiroaki

    2017-01-01

    Part I of this paper introduced a Lagrangian variational formulation for nonequilibrium thermodynamics of discrete systems. This variational formulation extends Hamilton's principle to allow the inclusion of irreversible processes in the dynamics. The irreversibility is encoded into a nonlinear nonholonomic constraint given by the expression of entropy production associated to all the irreversible processes involved. In Part II, we develop this formulation for the case of continuum systems by extending the setting of Part I to infinite dimensional nonholonomic Lagrangian systems. The variational formulation is naturally expressed in the material representation, while its spatial version is obtained via a nonholonomic Lagrangian reduction by symmetry. The theory is illustrated with the examples of a viscous heat conducting fluid and its multicomponent extension including chemical reactions and mass transfer.

  12. Market-Based Coordination of Thermostatically Controlled Loads—Part II: Unknown Parameters and Case Studies

    SciTech Connect

    Li, Sen; Zhang, Wei; Lian, Jianming; Kalsi, Karanjit

    2016-03-01

    This two-part paper considers the coordination of a population of Thermostatically Controlled Loads (TCLs) with unknown parameters to achieve group objectives. The problem involves designing the bidding and market clearing strategy to motivate self-interested users to realize efficient energy allocation subject to a peak power constraint. The companion paper (Part I) formulates the problem and proposes a load coordination framework using the mechanism design approach. To address the unknown parameters, Part II of this paper presents a joint state and parameter estimation framework based on the expectation maximization algorithm. The overall framework is then validated using real-world weather data and price data, and is compared with other approaches in terms of aggregated power response. Simulation results indicate that our coordination framework can effectively improve the efficiency of the power grid operations and reduce power congestion at key times.

  13. Three generations of zirconia: 
From veneered to monolithic. Part II.

    PubMed

    Stawarczyk, Bogna; Keul, Christin; Eichberger, Marlis; Figge, David; Edelhoff, Daniel; Lümkemann, Nina

    2017-01-01

    This article presents the historical development of the different generations of zirconia and their range of indications, from veneered to monolithic zirconia restorations. While Part I concentrated on detailed information about the development of zirconia for dental use and the mechanical and optical properties, Part II deals with the resulting guidelines for working with the relevant generations by summarizing the correct cementation procedure. Furthermore, this part also focuses on translucency measurements for better characterization and understanding of the different materials. The results obtained from measuring light transmission and contrast ratio are compared and discussed in detail, with the aid of clinical photographs. Finally, the reader is given practice-relevant recommendations for different areas of clinical use of the zirconia generations along with advice on how to process them appropriately.

  14. Advances in explosives analysis—part II: photon and neutron methods

    DOE PAGES

    Brown, Kathryn E.; Greenfield, Margo T.; McGrane, Shawn D.; ...

    2015-10-07

    The number and capability of explosives detection and analysis methods have increased dramatically since publication of the Analytical and Bioanalytical Chemistry special issue devoted to Explosives Analysis [Moore DS, Goodpaster JV, Anal Bioanal Chem 395:245–246, 2009]. Here we review and critically evaluate the latest (the past five years) important advances in explosives detection, with details of the improvements over previous methods, and suggest possible avenues towards further advances in, e.g., stand-off distance, detection limit, selectivity, and penetration through camouflage or packaging. Our review consists of two parts. Part I discussed methods based on animals, chemicals (including colorimetry, molecularly imprinted polymers,more » electrochemistry, and immunochemistry), ions (both ion-mobility spectrometry and mass spectrometry), and mechanical devices. In Part II, we review methods based on photons, from very energetic photons including X-rays and gamma rays down to the terahertz range, and neutrons.« less

  15. Advances in explosives analysis—part II: photon and neutron methods

    SciTech Connect

    Brown, Kathryn E.; Greenfield, Margo T.; McGrane, Shawn D.; Moore, David S.

    2015-10-07

    The number and capability of explosives detection and analysis methods have increased dramatically since publication of the Analytical and Bioanalytical Chemistry special issue devoted to Explosives Analysis [Moore DS, Goodpaster JV, Anal Bioanal Chem 395:245–246, 2009]. Here we review and critically evaluate the latest (the past five years) important advances in explosives detection, with details of the improvements over previous methods, and suggest possible avenues towards further advances in, e.g., stand-off distance, detection limit, selectivity, and penetration through camouflage or packaging. Our review consists of two parts. Part I discussed methods based on animals, chemicals (including colorimetry, molecularly imprinted polymers, electrochemistry, and immunochemistry), ions (both ion-mobility spectrometry and mass spectrometry), and mechanical devices. In Part II, we review methods based on photons, from very energetic photons including X-rays and gamma rays down to the terahertz range, and neutrons.

  16. A legacy of struggle: the OSHA ergonomics standard and beyond, Part II.

    PubMed

    Delp, Linda; Mojtahedi, Zahra; Sheikh, Hina; Lemus, Jackie

    2014-11-01

    The OSHA ergonomics standard issued in 2000 was repealed within four months through a Congressional resolution that limits future ergonomics rulemaking. This section continues the conversation initiated in Part I, documenting a legacy of struggle for an ergonomics standard through the voices of eight labor, academic, and government key informants. Part I summarized important components of the standard; described the convergence of labor activism, research, and government action that laid the foundation for a standard; and highlighted the debates that characterized the rulemaking process. Part II explores the anti-regulatory political landscape of the 1990s, as well as the key opponents, power dynamics, and legal maneuvers that led to repeal of the standard. This section also describes the impact of the ergonomics struggle beyond the standard itself and ends with a discussion of creative state-level policy initiatives and coalition approaches to prevent work-related musculoskeletal disorders (WMSDs) in today's sociopolitical context.

  17. PREFACE: Part II of the Proceedings of the 25th International Conference on Low Temperature Physics

    NASA Astrophysics Data System (ADS)

    Kes, Peter; Jochemsen, Reyer

    2009-03-01

    This Issue of Journal of Physics: Conference Series forms Part II of the Proceedings of the 25th International Conference on Low Temperature Physics (LT25) held in Amsterdam, The Netherlands, 6-13 August 2008. Part II contains the papers of short oral and poster presentations. In addition, it provides general information about the LT25 conference, such as a Report from the Organizers, an Activity Report to the IUPAP of the C5 Chairs, an overview of Committees, Sponsors and Exhibitors, and some Conference Statistics. Part I of the Proceedings of LT25 is a special issue of Journal of Physics: Condensed Matter. It contains the majority of the special invited lectures, such as the London Prize Lectures, the IUPAP Young Scientist Award Lectures, the Plenary and Half Plenary and Public Lectures, and the Historical Lectures presented at the conference excursion to Leiden. The JPCM LT25 special issue is available for free for a period of one year from publication (Journal of Physics: Condensed Matter). To ensure the high publication standard mandated by Journal of Physics: Condensed Matter and Journal of Physics: Conference Series, every paper was reviewed by at least one referee before it was accepted for publication. The Editors are indebted to many colleagues for invaluable assistance in the preparation and with the reviewing of the 900 papers appearing in Parts I and II of these Proceedings. In particular, we like to thank Carlo Beenakker, Jeroen van den Brink, Hans Brom, Jos de Jongh, Horst Rogalla, and Fons de Waele. Guest Editors Peter Kes and Reijer Jochemsen Leiden University, The Netherlands Conference logo

  18. Determination of Pb(II) by sequential injection/stripping analysis at all-plastic electrochemical fluidic cells with integrated composite electrodes.

    PubMed

    Kokkinos, Christos; Economou, Anastasios; Goddard, Nicholas G; Fielden, Peter R; Baldock, Sara J

    2016-06-01

    This work reports the development of a sequential injection/stripping analysis method for the determination of trace Pb(II) at injection-moulded electrochemical fluidic cells. Conducting carbon fibre-loaded polystyrene electrodes were integrated within the plastic cells. The flow-through cells were incorporated into a home-made sequential injection analysis (SIA) manifold. Different experimental parameters for the detection of Pb(II) were investigated including the type and concentration of the supporting electrolyte, the conditions of the stripping step, the volume of the sample, the flow rate and the accumulation potential. The LOD for Pb(II) was 0.5μgL(-1), the within-cell % relative standard deviation (n=8) was 3.1% and the between-cell % relative standard deviation (n=5) was 8.9% for 25μgL(-1) Pb(II). The cells were applied to the determination of Pb(II) in tapwater and a phosphate fertilizer sample.

  19. A sensitive, selective and rapid determination of lead(II) ions in real-life samples using an electrochemically reduced graphene oxide-graphite reinforced carbon electrode.

    PubMed

    Hamsawahini, Kunashegaran; Sathishkumar, Palanivel; Ahamad, Rahmalan; Yusoff, Abdull Rahim Mohd

    2015-11-01

    In this study, a sensitive and cost-effective electrochemically reduced graphene oxide (ErGO) on graphite reinforced carbon (GRC) was developed for the detection of lead (Pb(II)) ions present in the real-life samples. A film of graphene oxide (GO) was drop-casted on GRC and their electrochemical properties were investigated using cyclic voltammetry (CV), amperometry and square wave voltammetry (SWV). Factors influencing the detection of Pb(II) ions, such as grades of GRC, constant applied cathodic potential (CACP), concentration of hydrochloric acid and drop-casting drying time were optimised. GO is irreversibly reduced in the range of -0.7 V to -1.6 V vs Ag/AgCl (3 M) in acidic condition. The results showed that the reduction behaviour of GO contributed to the high sensitivity of Pb(II) ions detection even at nanomolar level. The ErGO-GRC showed the detection limit of 0.5 nM and linear range of 3-15 nM in HCl (1 M). The developed electrode has potential to be a good candidate for the determination of Pb(II) ions in different aqueous system. The proposed method gives a good recovery rate of Pb(II) ions in real-life water samples such as tap water and river water. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. On waves in gases. Part II: Interaction of sound with magnetic and internal modes

    NASA Astrophysics Data System (ADS)

    Campos, L. M. B. C.

    1987-04-01

    This work completes a two-part review on waves in gases, of which the first part

    [Rev. Mod. Phys. 58, 117 (1986)]
    dealt with the modern aspects of acoustics of jets, turbulence, and ducts; this second part extends the range of topics from sound to magnetic, internal, and (to a lesser extent) inertial waves, thus considering all four restoring forces (pressure, gravity, and Lorentz and Coriolis forces). The motivations for the study of these waves were outlined in the introduction to Part I. Part II reviews the coupling of acoustic, magnetic, and internal waves, in four stages: in Sec. I dispersion relations are used to study the propagation and radiation of magneto-acoustic-gravity-inertial waves in media for which the wave speeds and scattering scales are constant; in Sec. II the case of linear waves in stratified media, with nonuniform propagation velocity, is then discussed by means of special functions, appearing as exact solutions of second-order problems; in Sec. III the study of linear waves with variable propagation speeds is extended to certain classes of higher-order problems including a discussion of cutoff frequencies, critical levels, partition of energy, mode coupling and conversion, etc; in Sec. IV the preceding studies are extended to damped and nonlinear waves, to include dissipation with variable damping scales and large disturbances in media under nonuniform external forces, such as magnetic flux tubes. The conclusion (Sec. V) sums up both parts of the review, in the sense that it deals with all types of waves in fluids; it mentions a few currently controversial topics, points out some directions for future research, and indicates methods available to address these issues.

  1. Part I - Viscous evolution of point vortex equilibria Part II - Effects of body elasticity on stability of fish motion

    NASA Astrophysics Data System (ADS)

    Jing, Fangxu

    2011-12-01

    Vortex dynamics and solid-fluid interactions are two of the most important and most studied topics in fluid dynamics for their relevance to a wide range of applications from geophysical flows to locomotion in moving fluids. In this work, we investigate two problems in two parts: Part I studies the viscous evolution of point vortex equilibria; Part II studies the effects of body elasticity on the passive stability of submerged bodies. In Part I, we describe the viscous evolution of point vortex configurations that, in the absence of viscosity, are in a state of fixed or relative equilibrium. In particular, we examine four cases, three of them correspond to relative equilibria in the inviscid point vortex model and one corresponds to a fixed equilibrium. Our goal is to elucidate the dominant transient dynamical features of the flow. A multi-Gaussian "core growing" type of model is typically used in high fidelity numerical simulations, but we propose to implement it as a low-order model for the flow field. We show that all four configurations immediately begin to rotate unsteadily. We then examine in detail the qualitative and quantitative evolution of the structures as they evolve, and for each case show the sequence of topological bifurcations that occur both in a fixed reference frame, and in an appropriately chosen rotating reference frame. Comparisons between the cases help to reveal different features of the viscous evolution for short and intermediate time scales of vortex structures. We examine the dynamical evolution of passive particles in the viscously evolving flows and interpret it in relation to the evolving streamline patterns. Although the low-order multi-Gaussian model does not exactly coincide with the Navier-Stokes solution, the two results show remarkable resemblances in many aspects. In Part II, we examine the effects of body geometry and elasticity on the passive stability of motion in a perfect fluid. Our main motivation is to understand the

  2. Electrochemiluminescence of an electrocatalytic action of etimicin on Tris(2,2'-bipyridyl)ruthenium(II) immobilized in Nafion modified carbon paste electrode.

    PubMed

    Zhuang, Yafeng; Zhang, Jintao

    2010-01-01

    A sensitive electrochemiluminescence (ECL) detection of etimicin at Tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3) (2+)]-Nafion modified carbon paste electrodes was developed. The immobilized Ru(bpy)(3) (2+) shows good electrochemical and photochemical activities. Electrochemical and electrochemiluminescence characterizations of the modified carbon electrodes were made by means of cyclic voltammetry and electrochemical impendence spectroscopy. The modified electrode showed an electrocatalytic response to the oxidation of etimicin, producing a sensitized ECL signal. The ECL sensor showed a linear response to etimicin in the range of 8.0-160.0 ng mL(-1) with a detection limit of 6.7 ng mL(-1). This method for etimicin determination possessed good sensitivity and reproducibility with a coefficient of variation of 5.1% (n = 7) at 100 ng mL(-1). The ECL sensor showed good selectivity and long-term stability. Its surface could be renewed quickly and reproducibly by a simple polish step.

  3. Halogen-free ionic liquid as an additive in zinc(II)-selective electrode: surface analyses as correlated to the membrane activity.

    PubMed

    Al-Asousi, Maryam F; Shoukry, Adel F; Bu-Olayan, Abdul Hadi

    2012-05-30

    Two conventional Zn(II) polyvinyl chloride (PVC) membrane electrodes have been prepared and characterized. They were based on dibenzo-24-crown-8 (DBC) as a neutral carrier, dioctyl phthalate (DOP) as a plasticizer, and potassium tetrakis (p-chlorophenyl) borate, KTpClPB or the halogen-free ionic liquid, tetraoctylammonium dodecylbenzene sulfonate [TOA][DBS] as an additive. The use of ionic liquid has been found to enhance the selectivity of the sensor. For each electrode, the surfaces of two membranes were investigated using X-ray photoelectron, ion-scattering spectroscopy and atomic force microscopy. One of the two membranes was conditioned by soaking it for 24 h in a 1.0×10(-3) M Zn(NO(3))(2) solution and the second was soaked in bi-distilled water for the same interval (24 h). Comparing the two surfaces indicated the following: (a) the high selectivity in case of using [TOA][DBS] as an additive is due to the extra mediation caused by the ionic liquid and (b) the working mechanism of the electrode is based on phase equilibrium at the surface of the membrane associated with ion transport through the bulk of the membrane.

  4. Fabrication and Investigation of Nickel-Alkaline Cells. Part 1. Fabrication of Nickel-Hydroxide Electrodes Using Electrochemical Impregnation Techniques

    DTIC Science & Technology

    1975-10-01

    electrodes show capacities as high as 9.5 ampere-hours per cubic inch after these cycles. The alcohol process has been scaled to pilot production, FORM 1473...expel residual nitrogen as ammonia. This procedure must be repeated several * Presently only nickel-cadmium cells are used in Air Force missions; Nickel...hydrates of nickel and cadmium nitrates followed by a heat treatment to decompose the imbibed nitrates to hydroxides(2,3). The final process in all Ni-Cd

  5. Gradation of mechanical properties in gas-diffusion electrode. Part 2: Heterogeneous carbon fiber and damage evolution in cell layers

    NASA Astrophysics Data System (ADS)

    Poornesh, K. K.; Cho, C. D.; Lee, G. B.; Tak, Y. S.

    In PEM fuel cell, gas-diffusion electrode (GDE) plays very significant role in force transmission from bipolar plate to the membrane. This paper investigates the effects of geometrical heterogeneities of gas-diffusion electrode layer (gas-diffusion layer (GDL) and catalyst layer (CL)) on mechanical damage evolution and propagation. We present a structural integrity principle of membrane electrode assembly (MEA) based on the interlayer stress transfer capacity and corresponding cell layer material response. Commonly observable damages such as rupture of hydrophobic coating and breakage of carbon fiber in gas-diffusion layer are attributed to the ductile to brittle phase transition within a single carbon fiber. Effect of material inhomogeneity on change in modulus, hardness, contact stiffness, and electrical contact resistance is also discussed. Fracture statistics of carbon fiber and variations in flexural strength of GDL are studied. The damage propagation in CL is perceived to be influenced by the type of gradation and the vicinity from which crack originates. Cohesive zone model has been proposed based on the traction-separation law to investigate the damage propagation throughout the two interfaces (carbon fiber/CL and CL/membrane).

  6. Study of an Ozone Composing Mechanism derived from the Third Element on Surface of Electrode using Oxygen Gas: Part 2

    NASA Astrophysics Data System (ADS)

    Murai, Akira; Nakajima, Tsuyoshi

    In our third experiment, we changed the density of nitrogen through the addition of heat energy to the anode. A computer simulation confirmed the same phenomenon. Then the copper anode was replaced with an antimony anode. We found that antimony worked better than nitrogen as a third element. Finally, in the fourth experiment, we used an industrial ozone generator including ceramic dielectrics and a titanium expanded metal electrode. A decrease in the temperature of the cooling water led to a proportional increase in ozone. It follows the formula of van't Hoff. After spattering the surface of the electrodes with argon gas and supplying the ozone generator with 99% oxygen, we were able to produce ozone which was more than 20% higher in concentration than primary state ozone under the same conditions. The ozone generator produced ozone in high yield efficiency due to the optimum density of a third element like nitrogen on the surface of the electrodes. Antimony works better than nitrogen does as a third element.

  7. PIC Simulations in Low Energy Part of PIP-II Proton Linac

    SciTech Connect

    Romanov, Gennady

    2014-07-01

    The front end of PIP-II linac is composed of a 30 keV ion source, low energy beam transport line (LEBT), 2.1 MeV radio frequency quadrupole (RFQ), and medium energy beam transport line (MEBT). This configuration is currently being assembled at Fermilab to support a complete systems test. The front end represents the primary technical risk with PIP-II, and so this step will validate the concept and demonstrate that the hardware can meet the specified requirements. SC accelerating cavities right after MEBT require high quality and well defined beam after RFQ to avoid excessive particle losses. In this paper we will present recent progress of beam dynamic study, using CST PIC simulation code, to investigate partial neutralization effect in LEBT, halo and tail formation in RFQ, total emittance growth and beam losses along low energy part of the linac.

  8. PHOTOMETRY OF TYPE II CEPHEID CANDIDATES FROM THE NORTHERN PART OF THE ALL SKY AUTOMATED SURVEY

    SciTech Connect

    Schmidt, Edward G.; Hemen, Brian; Rogalla, Danielle; Thacker-Lynn, Lauren E-mail: bhemen1@bigred.unl.edu E-mail: lthacke1@bigred.unl.edu

    2009-06-15

    We have obtained VR photometry of 282 Cepheid variable star candidates from the northern part of the All Sky Automated Survey (ASAS). These together with data from the ASAS and the Northern Sky Variability Survey (NSVS) were used to redetermine the periods of the stars. We divided the stars into four groups based on location in a plot of mean color, (V-R), versus period. Two of the groups fell within the region of the diagram containing known type II Cepheids and yielded 14 new highly probable type II Cepheids. The properties of the remaining stars in these two groups are discussed but their nature remains uncertain. Unexplained differences exist between the sample of stars studied here and a previous sample drawn from the NSVS by Akerlof et al. This suggests serious biases in the identification of variables in different surveys.

  9. REINFORCEMENT IN CLASSROOM LEARNING. PART II, STUDIES OF REINFORCEMENT IN SIMULATED CLASSROOM SITUATIONS. PART III, IDENTIFICATION OF REINFORCERS OF HUMAN BEHAVIOR.

    ERIC Educational Resources Information Center

    TRAVERS, ROBERT M.W.; AND OTHERS

    REINFORCEMENT CONCEPTS DERIVED LARGELY FROM RESEARCH OF SUBHUMAN SUBJECTS WERE TESTED FOR APPLICABILITY TO HUMAN-LEARNING SITUATIONS SIMILAR TO THOSE THAT OCCUR IN SCHOOLS. A SERIES OF EXPLORATORY STUDIES CONDUCTED IS DESCRIBED IN PART II OF THIS REPORT. IN PART III, TWO EXPERIMENTS CONDUCTED TO DETERMINE THE REINFORCING VALUE OF DIFFERENT STIMULI…

  10. Integration of CdSe/CdSexTe1-x Type-II Heterojunction Nanorods into Hierarchically Porous TiO2 Electrode for Efficient Solar Energy Conversion.

    PubMed

    Lee, Sangheon; Flanagan, Joseph C; Kang, Joonhyeon; Kim, Jinhyun; Shim, Moonsub; Park, Byungwoo

    2015-12-07

    Semiconductor sensitized solar cells, a promising candidate for next-generation photovoltaics, have seen notable progress using 0-D quantum dots as light harvesting materials. Integration of higher-dimensional nanostructures and their multi-composition variants into sensitized solar cells is, however, still not fully investigated despite their unique features potentially beneficial for improving performance. Herein, CdSe/CdSe(x)Te(1-x) type-II heterojunction nanorods are utilized as novel light harvesters for sensitized solar cells for the first time. The CdSe/CdSe(x)Te(1-x) heterojunction-nanorod sensitized solar cell exhibits ~33% improvement in the power conversion efficiency compared to its single-component counterpart, resulting from superior optoelectronic properties of the type-II heterostructure and 1-octanethiol ligands aiding facile electron extraction at the heterojunction nanorod-TiO(2) interface. Additional ~32% enhancement in power conversion efficiency is achieved by introducing percolation channels of large pores in the mesoporous TiO(2) electrode, which allow 1-D sensitizers to infiltrate the entire depth of electrode. These strategies combined together lead to 3.02% power conversion efficiency, which is one of the highest values among sensitized solar cells utilizing 1-D nanostructures as sensitizer materials.

  11. Construction and evaluation of a flow-through cell adapted to a commercial static mercury drop electrode (SMDE) to study the adsorption of Cd(II) and Pb(II) on vermiculite.

    PubMed

    Abate, Gilberto; Lichtig, Jaim; Masini, Jorge C

    2002-09-12

    This paper describes the construction and application of a robust flow-through cell for use with the capillary of a commercial static mercury drop electrode. Linearity of peak current was observed up to 0.50 mumol l(-1) for Cd(II) or Pb(II) in anodic stripping voltammetry experiments performed under continuous flow during the deposition step, using 120 s of deposition time and flow rate of 4.0 ml min(-1). Under these conditions the limits of detection for Cd(II) and Pb(II) were 13 and 17 nmol l(-1), respectively. An analytical throughput of 20 analyses per h was possible using 10 s for cleaning the cell between two samples and including the time needed for the potential scan, which was performed with the flow stopped, using the differential pulse mode for current sampling. The linear dynamic range can be extended up to 5 mumol l(-1) for both cations if the deposition time is decreased to 30 s, a condition in which the sampling throughput is 35 analyses per h. The proposed manifold was used to study the adsorption rates of Cd(II) and Pb(II) onto vermiculite at different pHs, allowing one to perform high sensitivity measurements at high sampling frequency, using low cost instrumentation.

  12. Extraction of Carbon Dioxide and Hydrogen from Seawater By an Electrolytic Cation Exchange Module (E-CEM) Part V: E-CEM Effluent Discharge Composition as aFunction of Electrode Water Composition

    DTIC Science & Technology

    2017-08-01

    Cation Exchange Module (E-CEM) Part V: E-CEM Effluent Discharge Composition as a Function of Electrode Water Composition August 1, 2017 Approved for...Electrolytic Cation Exchange Module (E-CEM) Part V: E-CEM Effluent Discharge Composition as a Function of Electrode Water Composition Heather D. Willauer...Unlimited Unclassified Unlimited 26 Heather D. Willauer (202) 767-2673 Electrolytic Cation Exchange Module (E-CEM) Carbon dioxide Hydrogen Carbon capture A

  13. PA impairment due to HIV infection. Part II: Building a professional support network. Forum.

    PubMed

    Behar, M; Bogstad, J R; Gage, L; James, D A; Mott, J S

    1989-11-01

    Several members of the AAPA's Lesbian and Gay Physician Assistants Caucus who participated in the roundtable PAs and HIV-Antibody Testing: The Need for Guidelines When the Practitioner Is at Risk (1989;13[5]:146-158) met with members of the 12-Step/Caduceus Caucus to begin developing a cooperative effort to assist PAs who test positive for antibodies to the human immunodeficiency virus, and to explore other HIV-associated impairment issues. Part II focuses on concerns of the provider who is HIV-antibody positive as well as ways PA groups can cooperate to raise the profession's conciousness further and recommend guidelines and policy.

  14. A framework for biodynamic feedthrough analysis--part II: validation and application.

    PubMed

    Venrooij, Joost; van Paassen, Marinus M; Mulder, Mark; Abbink, David A; Mulder, Max; van der Helm, Frans C T; Bulthoff, Heinrich H

    2014-09-01

    Biodynamic feedthrough (BDFT) is a complex phenomenon, that has been studied for several decades. However, there is little consensus on how to approach the BDFT problem in terms of definitions, nomenclature, and mathematical descriptions. In this paper, the framework for BDFT analysis, as presented in Part I of this dual publication, is validated and applied. The goal of this framework is twofold. First of all, it provides some common ground between the seemingly large range of different approaches existing in BDFT literature. Secondly, the framework itself allows for gaining new insights into BDFT phenomena. Using recently obtained measurement data, parts of the framework that were not already addressed elsewhere, are validated. As an example of a practical application of the framework, it will be demonstrated how the effects of control device dynamics on BDFT can be understood and accurately predicted. Other ways of employing the framework are illustrated by interpreting the results of three selected studies from the literature using the BDFT framework. The presentation of the BDFT framework is divided into two parts. This paper, Part II, addresses the validation and application of the framework. Part I, which is also published in this journal issue, addresses the theoretical foundations of the framework. The work is presented in two separate papers to allow for a detailed discussion of both the framework's theoretical background and its validation.

  15. Fabrication and Investigation of Nickel-Alkaline Cells. Part 2. Analysis of Ethanolic Metal Nitrate Solutions Used in Fabrication of Nickel Hydroxide Electrodes

    DTIC Science & Technology

    1975-10-01

    Natioal Techucal It Sevice U. S. DEPARTMENT OF COMMERCE . 3S0.9 AFAPL.TR.75-34 Part II FABRICATION AND INVESTIGATION OF NICKEL-ALKALINE CELLS Part II...approved f publication. 1%VD F. PICKETT Project Engineer FOR THE COMANDR ,. Technical Area Manager Copies of this report should not be returned 01l0g, "tar...and D. F. Pickett, Proceedings of the 9th IECEC Conferen San Francisco, CA, Aug 1974, pp. 873-879). In order to control quality of DO , 1473 EDITION

  16. Part I: Sound color in the music of Gyorgy Kurtag, Part II: "Leopard's Path," thirteen visions for chamber ensemble

    NASA Astrophysics Data System (ADS)

    Iachimciuc, Igor

    The dissertation is in two parts, a theoretical study and a musical composition. In Part I the music of Gyorgy Kurtag is analyzed from the point of view of sound color. A brief description of what is understood by the term sound color, and various ways of achieving specific coloristic effects, are presented in the Introduction. An examination of Kurtag's approaches to the domain of sound color occupies the chapters that follow. The musical examples that are analyzed are selected from Kurtag's different compositional periods, showing a certain consistency in sound color techniques, the most important of which are already present in the String Quartet, Op. 1. The compositions selected for analysis are written for different ensembles, but regardless of the instrumentation, certain principles of the formation and organization of sound color remain the same. Rather than relying on extended instrumental techniques, Kurtag creates a large variety of sound colors using traditional means such as pitch material, register, density, rhythm, timbral combinations, dynamics, texture, spatial displacement of the instruments, and the overall musical context. Each sound color unit in Kurtag's music is a separate entity, conceived as a complete microcosm. Sound color units can either be juxtaposed as contrasting elements, forming sound color variations, or superimposed, often resulting in a Klangfarbenmelodie effect. Some of the same gestural figures (objets trouves) appear in different compositions, but with significant coloristic modifications. Thus, the principle of sound color variations is not only a strong organizational tool, but also a characteristic stylistic feature of the music of Gyorgy Kurtag. Part II, Leopard's Path (2010), for flute, clarinet, violin, cello, cimbalom, and piano, is an original composition inspired by the painting of Jesse Allen, a San Francisco based artist. The composition is conceived as a cycle of thirteen short movements. Ten of these movements are

  17. Part I. Inviscid, Swirling Flows and Vortex Breakdown. Part II. a Numerical Investigation of the Lundgren Turbulence Model.

    NASA Astrophysics Data System (ADS)

    Buntine, James Douglas

    Part I. A study of the behaviour of an inviscid, swirling fluid is performed. This flow can be described by the Squire-Long equation if the constraints of time -independence and axisymmetry are invoked. The particular case of flow through a diverging pipe is selected and a study is conducted to determine over what range of parameters (both pipe inlet conditions and geometry) does a (unique) solution exist. The work is performed with a view to understanding how the phenomenon of vortex breakdown develops. Experiments and previous numerical studies have indicated that the flow is sensitive to boundary conditions particularly at the pipe inlet. A "quasi-cylindrical" simplification of the Squire-Long equation is compared with the more complete model and shown to be able to account for most of its behaviour. An advantage of this latter representation is the relatively undetailed description of the flow geometry it requires in order to calculate a solution. "Criticality" or the ability of small disturbances to propagate upstream is related to results of the quasi -cylindrical and axisymmetric flow models. This leads to an examination of claims made by researchers such as Benjamin and Hall concerning the interrelationship between "failure" of the quasi-cylindrical model and the occurrence of a "critical" flow state. Other criteria for predicting the onset of vortex breakdown are considered in the context of the model employed, particularly those of Brown & Lopez and Spall, Gatski & Grosch. Part II. Lundgren (1982) developed an analytical model for homogeneous turbulence based on a collection of contracting spiral vortices each embedded in an axisymmetric strain field. Using asymptotic approximations he was able to deduce the Kolmogorov k^{-5/3} behaviour for inertial scales in the turbulence energy spectrum. Pullin & Saffman have enlarged upon his work to make a number of predictions about the behaviour of turbulence described by the model. This work investigates the

  18. Catalytic hydrogen evolution in cathodic stripping voltammetry on a mercury electrode in the presence of cobalt(II) ion and phenylthiourea or thiourea.

    PubMed

    Spătaru, N; Bănica, F G

    2001-11-01

    The system Co(II)-phenylthiourea (PTU)-borax buffer was investigated by cathodic stripping voltammetry (CSV) at a hanging mercury drop electrode. The results of the voltammetric measurements showed that the presence of both PTU and Co(II) gives rise to a new irreversible peak at about -1.5 V. Based upon our previous results obtained in the study of other sulfur compounds and the sulfide ion itself, the peak was ascribed to the catalytic hydrogen evolution superimposed on the reduction of the coordinated Co(II) ion. The catalyst itself is a Co(II) complex with the sulfide ion produced by the decomposition of the analyte during the deposition step. The influence of PTU and cobalt concentration, accumulation conditions and stripping parameters was investigated and complementary data on thiourea are included. The results showed that the measurement of the catalytic hydrogen evolution peak current can be used as a basis for a simple, accurate and rapid method for the determination of PTU within the concentration range 10-100 nM. The catalytic method is relatively free of interferences and could be a suitable alternative for cases in which the stripping peak due to mercury ion reduction in the accumulated mercury compound is disturbed by some interference.

  19. Assessing and addressing moral distress and ethical climate Part II: neonatal and pediatric perspectives.

    PubMed

    Sauerland, Jeanie; Marotta, Kathleen; Peinemann, Mary Anne; Berndt, Andrea; Robichaux, Catherine

    2015-01-01

    Moral distress remains a pervasive and, at times, contested concept in nursing and other health care disciplines. Ethical climate, the conditions and practices in which ethical situations are identified, discussed, and decided, has been shown to exacerbate or ameliorate perceptions of moral distress. The purpose of this mixed-methods study was to explore perceptions of moral distress, moral residue, and ethical climate among registered nurses working in an academic medical center. Two versions of the Moral Distress Scale in addition to the Hospital Ethical Climate Survey were used, and participants were invited to respond to 2 open-ended questions. Part I reported the findings among nurses working in adult acute and critical care units. Part II presents the results from nurses working in pediatric/neonatal units. Significant differences in findings between the 2 groups are discussed. Subsequent interventions developed are also presented.

  20. Signal classification using global dynamical models, Part II: SONAR data analysis

    NASA Astrophysics Data System (ADS)

    Kremliovsky, Michael; Kadtke, James

    1996-06-01

    In Part I of this paper, we described a numerical method for nonlinear signal detection and classification which made use of techniques borrowed from dynamical systems theory. Here in Part II of the paper, we will describe an example of data analysis using this method, for data consisting of open ocean acoustic (SONAR) recordings of marine mammal transients, supplied from NUWC sources. The purpose here is two-fold: first to give a more operational description of the technique and provide rules-of-thumb for parameter choices; and second to discuss some new issues raised by the analysis of non-ideal (real-world) data sets. The particular data set considered here is quite non-stationary, relatively noisy, is not clearly localized in the background, and as such provides a difficult challenge for most detection/classification schemes.

  1. Pregnancy in women with renal disease. Part II: specific underlying renal conditions.

    PubMed

    Vidaeff, Alex C; Yeomans, Edward R; Ramin, Susan M

    2008-08-01

    The obstetric outcome in women with kidney disease has improved in recent years due to continuous progress in obstetrics and neonatology, as well as better medical management of hypertension and renal disease. However, every pregnancy in these women remains a high-risk pregnancy. When considering the interaction between renal disease and pregnancy, maternal outcomes are related to the initial level of renal dysfunction more than to the specific underlying disease. With regards to fetal outcomes, though, a distinction may exist between renal dysfunction resulting from primary renal disease and that in which renal involvement is part of a systemic disease. In part II of this review, some specific causes of renal failure affecting pregnancy are considered.

  2. Exploring Cancer Therapeutics with Natural Products from African Medicinal Plants, Part II: Alkaloids, Terpenoids and Flavonoids.

    PubMed

    Nwodo, Justina N; Ibezim, Akachukwu; Simoben, Conrad V; Ntie-Kang, Fidele

    2016-01-01

    Cancer stands as second most common cause of disease-related deaths in humans. Resistance of cancer to chemotherapy remains challenging to both scientists and physicians. Medicinal plants are known to contribute significantly to a large population of Africa, which is to a very large extent linked to folkloric claims which is part of their livelihood. In this review paper, the potential of naturally occurring anti-cancer agents from African flora has been explored, with suggested modes of action, where such data is available. Literature search revealed plant-derived compounds from African flora showing anti-cancer and/or cytotoxic activities, which have been tested in vitro and in vivo. This corresponds to 400 compounds (from mildly active to very active) covering various compound classes. However, in this part II, we only discussed the three major compound classes which are: flavonoids, alkaloids and terpenoids.

  3. A US perspective on fast reactor fuel fabrication technology and experience. Part II: Ceramic fuels

    NASA Astrophysics Data System (ADS)

    Burkes, Douglas E.; Fielding, Randall S.; Porter, Douglas L.; Meyer, Mitchell K.; Makenas, Bruce J.

    2009-08-01

    This paper is Part II of a review focusing on the United States experience with oxide, carbide, and nitride fast reactor fuel fabrication. Over 60 years of research in fuel fabrication by government, national laboratories, industry, and academia has culminated in a foundation of research and resulted in significant improvements to the technologies employed to fabricate these fuel types. This part of the review documents the current state of fuel fabrication technologies in the United States for each of these fuel types, some of the challenges faced by previous researchers, and how these were overcome. Knowledge gained from reviewing previous investigations will aid both researchers and policy makers in forming future decisions relating to nuclear fuel fabrication technologies.

  4. Patient variation in veterinary medicine--part II--influence of physiological variables.

    PubMed

    Modric, S; Martinez, M

    2011-06-01

    In veterinary medicine, the characterization of a drug's pharmacokinetic properties is generally based upon data that are derived from studies that employ small groups of young healthy animals, often of a single breed. In Part I of the series, we focused on the potential influence of disease processes, stress, pregnancy and lactation on drug pharmacokinetics. In this Part II of the series, we consider other covariates, such as gender, heritable traits, age, body composition, and circadian rhythms. The impact of these factors with respect to predicting the relationship between dose and drug exposure characteristics within an animal population is illustrated through the use of Monte Carlo simulations. Ultimately, an appreciation of these potential influences will improve the prediction of situations when dose adjustments may be appropriate. © 2010 Blackwell Publishing Ltd.

  5. Transferring diffractive optics from research to commercial applications: Part II - size estimations for selected markets

    NASA Astrophysics Data System (ADS)

    Brunner, Robert

    2014-04-01

    In a series of two contributions, decisive business-related aspects of the current process status to transfer research results on diffractive optical elements (DOEs) into commercial solutions are discussed. In part I, the focus was on the patent landscape. Here, in part II, market estimations concerning DOEs for selected applications are presented, comprising classical spectroscopic gratings, security features on banknotes, DOEs for high-end applications, e.g., for the semiconductor manufacturing market and diffractive intra-ocular lenses. The derived market sizes are referred to the optical elements, itself, rather than to the enabled instruments. The estimated market volumes are mainly addressed to scientifically and technologically oriented optical engineers to serve as a rough classification of the commercial dimensions of DOEs in the different market segments and do not claim to be exhaustive.

  6. Design of site specific radiopharmaceuticals for tumor imaging. (Parts I and II)

    SciTech Connect

    Van Dort, M.E.

    1983-01-01

    Part I. Synthetic methods were developed for the preparation of several iodinated benzoic acid hydrazides as labeling moieties for indirect tagging of carbonyl-containing bio-molecules and potential tumor-imaging agents. Biodistribution studies conducted in mice on the derivatives having the I-125 label ortho to a phenolic OH demonstrated a rapid in vivo deiodination. Part II. The reported high melanin binding affinity of quinoline and other heterocyclic antimalarial drugs led to the development of many analogues of such molecules as potential melanoma-imaging agents. Once such analogue iodochloroquine does exhibit high melanin binding, but has found limited clinical use due to appreciable accumulation in non-target tissues such as the adrenal cortex and inner ear. This project developed a new series of candidate melanoma imaging agents which would be easier to radio-label, could yield higher specific activity product, and which might demonstrate more favorable pharmacokinetic and dosimetric characteristics compared to iodochloroquine.

  7. Investigational drug tracking: phases I-III and NDA submissions--Part II.

    PubMed

    Grant, K L

    1994-10-01

    The author catalogs over 800 investigational drugs/biologicals currently in Phase I, II or III clinical trials or drugs/biologicals submitted to the FDA as new drug applications. Part I of this article appeared in the September issue of Hospital Pharmacy. The list assists in predicting when new drugs will be marketed. The entries include generic/chemical name, investigational drug number, synonyms, trade names, manufacturers, clinical trial status, predicted approval year, indications or drug class, whether the drug has been developed through biotechnology, and references. Entries were gleaned from medical journals, stock market analysis publications, and the Pharmaceutical Manufacturers Association's Medicines in Development Series. The list is alphabetized by the generic/chemical name or investigational drug number and cross-indexed by the trade name and synonyms. The list reflects those drugs which were not FDA approved as of April 15, 1994. Part I concludes with the remaining alphabetical listing by generic/chemical name or investigational drug number.

  8. Signal classification using global dynamical models, Part II: SONAR data analysis

    SciTech Connect

    Kremliovsky, M.; Kadtke, J.

    1996-06-01

    In Part I of this paper, we described a numerical method for nonlinear signal detection and classification which made use of techniques borrowed from dynamical systems theory. Here in Part II of the paper, we will describe an example of data analysis using this method, for data consisting of open ocean acoustic (SONAR) recordings of marine mammal transients, supplied from NUWC sources. The purpose here is two-fold: first to give a more operational description of the technique and provide rules-of-thumb for parameter choices; and second to discuss some new issues raised by the analysis of non-ideal (real-world) data sets. The particular data set considered here is quite non-stationary, relatively noisy, is not clearly localized in the background, and as such provides a difficult challenge for most detection/classification schemes. {copyright} {ital 1996 American Institute of Physics.}

  9. Investigations about Starting Cracks in DC-Casting of 6063-Type Billets Part II: Modelling Results

    NASA Astrophysics Data System (ADS)

    Jensen, E. K.; Schneider, W.

    Influence on starting crack tendency of varying a number of casting parameters has been studied by experiments, Part I (1), and by model calculations, Part II. Both studies point to starting block shape as a most important single factor in controlling starting cracks. By using the thermal model ALSIM-2 in analysing initial experimental results, the variable heat transfer towards the starting block was determined. This made possible a satisfactory model analysis of the starting phase and likewise the formulation of a useful cracking concept. Thus by using calculated and measured liquid pool depth curve in the starting phase of casting as a basis, an effective starting block shape was found. This new shape practically eliminates the starting crack problems in extrusion billets of the AA6063 type alloys.

  10. Caterpillars and moths: Part II. Dermatologic manifestations of encounters with Lepidoptera.

    PubMed

    Hossler, Eric W

    2010-01-01

    Caterpillars and moths (order Lepidoptera) are uncommonly recognized causes of adverse cutaneous reactions, such as localized stings, papular dermatitis, and urticarial wheals. These reactions are typically mild and self-limited; however, in South America, the sting of Lonomia caterpillars can cause a potentially fatal hemorrhagic diathesis related to massive fibrinolysis. In addition, ocular inflammation and prominent arthralgias have been reported to be caused by caterpillar exposures. Therapies for mucocutaneous reactions to Lepidoptera are largely empiric, with the exception of antivenin against Lonomia obliqua envenomation. Part II of this two-part series on caterpillars and moths reviews the varied symptoms caused by Lepidopteran exposures, reviews the differential diagnosis, and discusses appropriate treatment algorithms.

  11. Microarchitectured solid oxide fuel cells with improved energy efficiency (Part II): Fabrication and characterization

    NASA Astrophysics Data System (ADS)

    Yoon, Chan; Liu, Mingfei; Yuan, Dajun; Guo, Rui; Liu, Meilin; Das, Suman

    2015-10-01

    Part I of this study presented a computational model-based approach for enhancing the performance of solid oxide fuel cells (SOFCs) with designed microarchitecture. The performance of such SOFCs was predicted to greatly improve through a systematic computational design and optimization approach. Part II here proves through experimental fabrication and characterization that microarchitectured SOFC performance can be improved as predicted by the model. A real and specific SOFC is chosen, fabricated and characterized to demonstrate the proof-of-concept. Fabrication techniques using sintering and laser ablation are demonstrated. Pore size and geometry are characterized by interferometry-based surface profilometry and scanning electron microscopy. SOFC button cell performance testing including power output performance and electrochemical impedance spectroscopy are performed. The results show that SOFC performance in a microarchitectured cell can be improved over a baseline button cell by 9-17% in current density and by 7-19% in power density.

  12. Mineral resources of parts of the Departments of Antioquia and Caldas, Zone II, Colombia

    USGS Publications Warehouse

    Hall, R.B.; Feininger, Tomas; Barrero, L.; Dario, Rico H.; ,; Alvarez, A.

    1970-01-01

    The mineral resources of an area of 40,000 sq km, principally in the Department of Antioquia, but including small parts of the Departments of Caldas, C6rdoba, Risaralda, and Tolima, were investigated during the period 1964-68. The area is designated Zone II by the Colombian Inventario Minero Nacional(lMN). The geology of approximately 45 percent of this area, or 18,000 sq km, has been mapped by IMN. Zone II has been a gold producer for centuries, and still produces 75 percent of Colombia's gold. Silver is recovered as a byproduct. Ferruginous laterites have been investigated as potential sources of iron ore but are not commercially exploitable. Nickeliferous laterite on serpentinite near Ure in the extreme northwest corner of the Zone is potentially exploitable, although less promising than similar laterites at Cerro Matoso, north of the Zone boundary. Known deposits of mercury, chromium, manganese, and copper are small and have limited economic potentia1. Cement raw materials are important among nonmetallic resources, and four companies are engaged in the manufacture of portland cement. The eastern half of Zone II contains large carbonate rock reserves, but poor accessibility is a handicap to greater development at present. Dolomite near Amalfi is quarried for the glass-making and other industries. Clay saprolite is abundant and widely used in making brick and tiles in backyard kilns. Kaolin of good quality near La Union is used by the ceramic industry. Subbituminous coal beds of Tertiary are an important resource in the western part of the zone and have good potential for greater development. Aggregate materials for construction are varied and abundant. Deposits of sodic feldspar, talc, decorative stone, and silica are exploited on a small scale. Chrysotils asbestos deposits north of Campamento are being developed to supply fiber for Colombia's thriving asbestos-cement industry, which is presently dependent upon imported fiber. Wollastonite and andalusite are

  13. The CCTC Quick-Reacting General War Gaming System (QUICK). Volume IV. Sortie Generation Subsystem. Parts I and II. Program Maintenance Manual. Change 2.

    DTIC Science & Technology

    1980-06-03

    No. Change No. Title Page, Part I 0 215 1 ii 2 216-260 0 iii-viii 2 260.1-260.2 2 ix 0 Title Page, Part II 0 1-1.2 2 ii -iii 2 2 2 iv 1 3 0 v 2 4-b 1 vi...Page ACKNOWLEDGMENT ......................................... ii ABSTRACT .................... ....................... ix 1. GENERAL...260.1 DD Form 1473 ............. . .......... .... .. .............. .. 260.3 Part II 4. PLANOUT MODULE

  14. Seismic risk analysis for General Electric Plutonium Facility, Pleasanton, California. Final report, part II

    SciTech Connect

    Not Available

    1980-06-27

    This report is the second of a two part study addressing the seismic risk or hazard of the special nuclear materials (SNM) facility of the General Electric Vallecitos Nuclear Center at Pleasanton, California. The Part I companion to this report, dated July 31, 1978, presented the seismic hazard at the site that resulted from exposure to earthquakes on the Calaveras, Hayward, San Andreas and, additionally, from smaller unassociated earthquakes that could not be attributed to these specific faults. However, while this study was in progress, certain additional geologic information became available that could be interpreted in terms of the existance of a nearby fault. Although substantial geologic investigations were subsequently deployed, the existance of this postulated fault, called the Verona Fault, remained very controversial. The purpose of the Part II study was to assume the existance of such a capable fault and, under this assumption, to examine the loads that the fault could impose on the SNM facility. This report first reviews the geologic setting with a focus on specifying sufficient geologic parameters to characterize the postulated fault. The report next presents the methodology used to calculate the vibratory ground motion hazard. Because of the complexity of the fault geometry, a slightly different methodology is used here compared to the Part I report. This section ends with the results of the calculation applied to the SNM facility. Finally, the report presents the methodology and results of the rupture hazard calculation.

  15. Experimental Demonstration of Frequency Regulation by Commercial Buildings – Part II: Results and Performance Evaluation

    DOE PAGES

    Vrettos, Evangelos; Kara, Emre Can; MacDonald, Jason; ...

    2016-11-15

    This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. We developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation in Part I. In Part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation,more » and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland Power Market (PJM) very accurately. In addition, we discuss potential effects of frequency regulation on building operation (e.g., increase in energy consumption, oscillations in supply air temperature, and effect on chiller cycling), and provide suggestions for real-world implementation projects. Our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.« less

  16. Experimental Demonstration of Frequency Regulation by Commercial Buildings – Part II: Results and Performance Evaluation

    SciTech Connect

    Vrettos, Evangelos; Kara, Emre Can; MacDonald, Jason; Andersson, Goran; Callaway, Duncan S.

    2016-11-15

    This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. We developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation in Part I. In Part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation, and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland Power Market (PJM) very accurately. In addition, we discuss potential effects of frequency regulation on building operation (e.g., increase in energy consumption, oscillations in supply air temperature, and effect on chiller cycling), and provide suggestions for real-world implementation projects. Our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.

  17. Analysis of Radionuclide Releases from the Fukushima Dai-ichi Nuclear Power Plant Accident Part II

    NASA Astrophysics Data System (ADS)

    Achim, Pascal; Monfort, Marguerite; Le Petit, Gilbert; Gross, Philippe; Douysset, Guilhem; Taffary, Thomas; Blanchard, Xavier; Moulin, Christophe

    2014-03-01

    The present part of the publication (Part II) deals with long range dispersion of radionuclides emitted into the atmosphere during the Fukushima Dai-ichi accident that occurred after the March 11, 2011 tsunami. The first part (Part I) is dedicated to the accident features relying on radionuclide detections performed by monitoring stations of the Comprehensive Nuclear Test Ban Treaty Organization network. In this study, the emissions of the three fission products Cs-137, I-131 and Xe-133 are investigated. Regarding Xe-133, the total release is estimated to be of the order of 6 × 1018 Bq emitted during the explosions of units 1, 2 and 3. The total source term estimated gives a fraction of core inventory of about 8 × 1018 Bq at the time of reactors shutdown. This result suggests that at least 80 % of the core inventory has been released into the atmosphere and indicates a broad meltdown of reactor cores. Total atmospheric releases of Cs-137 and I-131 aerosols are estimated to be 1016 and 1017 Bq, respectively. By neglecting gas/particulate conversion phenomena, the total release of I-131 (gas + aerosol) could be estimated to be 4 × 1017 Bq. Atmospheric transport simulations suggest that the main air emissions have occurred during the events of March 14, 2011 (UTC) and that no major release occurred after March 23. The radioactivity emitted into the atmosphere could represent 10 % of the Chernobyl accident releases for I-131 and Cs-137.

  18. Decontamination effects of low-temperature plasma generated by corona discharge. Part II: new insights.

    PubMed

    Scholtz, V; Julák, J; Kríha, V; Mosinger, J; Kopecká, S

    2007-01-01

    The second part of our paper presents the results of experiments with the decontamination of surfaces by low-temperature plasma generated by corona discharge in air at atmospheric pressure. A simple device is described and the effects of the corona discharge on model microorganisms, viz. the yeast Candida albicans, Gram-negative bacteria Escherichia coli, Enterobacter aerogenes, Neisseria sicca, Stenotrophomonas maltophilia, Gram-positive bacteria Deinococcus radiodurans, Enterococcus faecium, Staphylococcus epidermidis, Streptococcus sanguinis, and vegetative and spore forms of Geobacillus stearothermophilus are discussed. A similar microbicidal effect after about one-minute exposure was observed in all vegetative forms of the microorganisms. Measurement in growth inhibition zones on a semisolid medium was used to determine the dependence of the microbicidal effect on exposure time and the distance between electrodes. Counting of colonies served to assess the microbicidal effect of the discharge on contaminated inert surfaces observable after more than 1 min exposure. Geobacillus stearothermophilus spores were found to have several times lower susceptibility to the action of the discharge and the microbicidal effect was observed only after an 8 min exposure. Reaction with the iodide reagent did not unambiguously demonstrate the difference between ozone and singlet oxygen as presumed active components of the corona. The area distribution of reactive oxygen species was determined; it was found to differ from the Wartburg law depending on exposure time. Qualitative evidence was obtained on the penetration of the reactive oxygen species into the semisolid medium.

  19. An Evaluative Survey Report on ESEA Title II: Fiscal Years 1966-1968. Part I, Analysis and Interpretation. Part II, Tables.

    ERIC Educational Resources Information Center

    Office of Education (DHEW), Washington, DC.

    This report provides benchmark data on the effects that the provision of school library resources, textbooks, and other instructional materials under Title II of the Elementary and Secondary Education Act (ESEA) has had on education in the nation's public and private elementary and secondary schools. The passage of Title II of ESEA set the stage…

  20. A model of neurovascular coupling and the BOLD response PART II.

    PubMed

    Mathias, E J; Plank, M J; David, T

    2017-04-01

    A mathematical model is developed which describes a signalling mechanism of neurovascular coupling with a model of a pyramidal neuron and its corresponding fMRI BOLD response. In the first part of two papers (Part I) we described the integration of the neurovascular coupling unit extended to include a complex neuron model, which includes the important Na/K ATPase pump, with a model that provides a BOLD signal taking its input from the cerebral blood flow and the metabolic rate of oxygen consumption. We showed that this produced a viable signal in terms of initial dip, positive and negative BOLD signals. In this paper (PART II) our model predicts the variations of the BOLD response due to variations in neuronal activity and indicates that the BOLD signal could be used as an initial biomarker for neuronal dysfunction or variations in the perfusion of blood to the cerebral tissue. We have compared the simulated hypoxic BOLD response to experimental BOLD signals observed in the hippocampus during hypoxia showing good agreement. This approach of combined quantitative modelling of neurovascular coupling response and its BOLD response will enable more specific assessment of a brain region.