Market Analysis and Material Evaluation of Coagulants for Reverse Osmosis Water Purification Units
1990-09-28
three identified primary coagulants. Electrocoagulation , an emerging technology, was also discovered as being a relatively new area of research with great...there is yet another avenue the Army needs to explore -- electrocoagulation . 4.3.2 Electrocoagulation | * Electrocoagulation processes utilize an...7). A typical electrocoagulator consists of a combination of a treating chamber, which operates as an electrolytic cell, with a water-inlet and a
Cathodic electrodeposition of ceramic and organoceramic materials. Fundamental aspects.
Zhitomirsky, I
2002-03-29
Electrodeposition of ceramic materials can be performed by electrophoretic (EPD) or electrolytic (ELD) deposition. Electrophoretic deposition is achieved via motion of charged particles towards an electrode under an applied electric field. Electrolytic deposition produces colloidal particles in cathodic reactions for subsequent deposition. Various electrochemical strategies and deposition mechanisms have been developed for electrodeposition of ceramic and organoceramic films, and are discussed in the present article. Electrode-position of ceramic and organoceramic materials includes mass transport, accumulation of particles near the electrode and their coagulation to form a cathodic deposit. Various types of interparticle forces that govern colloidal stability in the absence and presence of processing additives are discussed. Novel theoretical contributions towards an interpretation of particle coagulation near the electrode surface are reviewed. Background information is given on the methods of particle charging, stabilization of colloids in aqueous and non-aqueous media, electrophoretic mobility of ceramic particles and polyelectrolytes, and electrode reactions. This review also covers recent developments in the electrodeposition of ceramic and organoceramic materials.
Zeolite-based hemostat QuikClot releases calcium into blood and promotes blood coagulation in vitro
Li, Jing; Cao, Wei; Lv, Xiao-xing; Jiang, Li; Li, Yue-jun; Li, Wang-zhou; Chen, Shao-zong; Li, Xue-yong
2013-01-01
Aim: To examine the changes in electrolyte concentrations after addition of zeolite-based hemostat QuikClot in blood and the effects of zeolite on blood coagulation in vitro. Methods: Fresh blood was taken from healthy adult volunteers and sheep, and the electrolyte concentrations in blood were measured using a blood electrolyte analyzer. Zeolite Saline Solution (ZSS) was prepared by addition of 2 g zeolite to 0.9% NaCl solution (4, 8, or 16 mL). The electrolytes in ZSS were measured using inductively coupled plasma atomic emission spectroscopy. The prothrombin time (PT) and activated partial thromboplastin time (APTT) of blood were measured using the test tube method. The activated clotting time (ACT) and clotting rate (CR) of blood were measured with Sonoclot Coagulation and Platelet Function Analyzer. Results: Addition of zeolite (50 and 100 mg) in 2 mL human blood significantly increased Ca2+ concentration, while Na+ and K+ concentrations were significantly decreased. Addition of zeolite (50 and 100 mg) in 0.9% NaCl solution (2 mL) caused similar changes in Ca2+ and Na+ concentrations. Si4+ (0.2434 g/L) and Al3+ (0.2575 g/L) were detected in ZSS (2 g/8 mL). Addition of ZSS in sheep blood shortened APTT in a concentration dependent manner, without changing PT. ZSS or aqueous solution of CaCl2 that contained Ca2+ concentration identical to that of ZSS significantly shortened ACT in human blood without significantly changing CR, and the effect of ZSS on ACT was not significantly different from that of CaCl2. Conclusion: Zeolite releases Ca2+ into blood, thus accelerating the intrinsic pathway of blood coagulation and shortening the clot formation time. PMID:23334236
Zeolite-based hemostat QuikClot releases calcium into blood and promotes blood coagulation in vitro.
Li, Jing; Cao, Wei; Lv, Xiao-xing; Jiang, Li; Li, Yue-jun; Li, Wang-zhou; Chen, Shao-zong; Li, Xue-yong
2013-03-01
To examine the changes in electrolyte concentrations after addition of zeolite-based hemostat QuikClot in blood and the effects of zeolite on blood coagulation in vitro. Fresh blood was taken from healthy adult volunteers and sheep, and the electrolyte concentrations in blood were measured using a blood electrolyte analyzer. Zeolite Saline Solution (ZSS) was prepared by addition of 2 g zeolite to 0.9% NaCl solution (4, 8, or 16 mL). The electrolytes in ZSS were measured using inductively coupled plasma atomic emission spectroscopy. The prothrombin time (PT) and activated partial thromboplastin time (APTT) of blood were measured using the test tube method. The activated clotting time (ACT) and clotting rate (CR) of blood were measured with Sonoclot Coagulation and Platelet Function Analyzer. Addition of zeolite (50 and 100 mg) in 2 mL human blood significantly increased Ca(2+) concentration, while Na(+) and K(+) concentrations were significantly decreased. Addition of zeolite (50 and 100 mg) in 0.9% NaCl solution (2 mL) caused similar changes in Ca(2+) and Na(+) concentrations. Si(4+) (0.2434 g/L) and Al(3+) (0.2575 g/L) were detected in ZSS (2 g/8 mL). Addition of ZSS in sheep blood shortened APTT in a concentration dependent manner, without changing PT. ZSS or aqueous solution of CaCl2 that contained Ca(2+) concentration identical to that of ZSS significantly shortened ACT in human blood without significantly changing CR, and the effect of ZSS on ACT was not significantly different from that of CaCl2. Zeolite releases Ca(2+) into blood, thus accelerating the intrinsic pathway of blood coagulation and shortening the clot formation time.
Arakcheev, E N; Brunman, V E; Brunman, M V; Konyashin, A V; Dyachenko, V A; Petkova, A P
Usage of complex automated electrolysis unit for drinking water disinfection and wastewater oxidation and coagulation is scoped, its ecological and energy efficiency is shown. Properties of technological process of anolyte production using membrane electrolysis of brine for water disinfection in municipal pipelines and potassium ferrate production using electrochemical dissolution of iron anode in NaOH solution for usage in purification plants are listed. Construction of modules of industrial prototype for anolyte and ferrate production and applied aspects of automation of complex electrolysis unit are proved. Results of approbation of electrolytic potassium ferrate for drinking water disinfection and wastewater, rain water and environmental water oxidation and coagulation are shown.
Mechanisms for naphthalene removal during electrolytic aeration.
Goel, Ramesh K; Flora, Joseph R V; Ferry, John
2003-02-01
Batch tests were performed to investigate chemical and physical processes that may result during electrolytic aeration of a contaminated aquifer using naphthalene as a model contaminant. Naphthalene degradation of 58-66% took place electrolytically and occurred at the same rates at a pH of 4 and 7. 1,4-naphthoquinone was identified as a product of the electrolysis. Stripping due to gases produced at the electrodes did not result in any naphthalene loss. Hydrogen peroxide (which may be produced at the cathode) did not have any effect on naphthalene, but the addition of ferrous iron (which may be present in aquifers) resulted in 67-99% disappearance of naphthalene. Chlorine (which may be produced from the anodic oxidation of chloride) can effectively degrade naphthalene at pH of 4, but not at a pH of 7. Mono-, di- and poly chloronaphthalenes were identified as oxidation products. Ferric iron coagulation (due to the oxidation of ferrous iron) did not significantly contribute to naphthalene loss. Overall, electrolytic oxidation and chemical oxidation due to the electrolytic by-products formed are significant abiotic processes that could occur and should be accounted for if bioremediation of PAH-contaminated sites via electrolytic aeration is considered. Possible undesirable products such as chlorinated compounds may be formed when significant amounts of chlorides are present.
do Vale-Júnior, Edilson; da Silva, Djalma R; Fajardo, Ana S; Martínez-Huitle, Carlos A
2018-08-01
Peroxi-coagulation (PC) is an interesting new process that has not been widely studied in the literature. This work presents the application of this technology to treat an azo dye synthetic effluent, studying the effect of different parameters including initial pH, current density (j), initial dye concentration and supporting electrolyte. The two former variables significantly affected the colour removal of the wastewater, followed by the initial dye concentration and the kind of electrolyte, in a lesser extent. The optimum operating conditions achieved were initial pH of 3.0, j = 33.3 mA cm -2 , 100 mg L -1 of methyl orange (MO) and Na 2 SO 4 as supporting electrolyte. The performance of PC was also compared to other electrochemical advanced processes, under similar experimental conditions. Results indicate that the kinetic decay of the MO increases in the following order: electrocoagulation (EC) < electrochemical oxidation (EO) with electrogenerated H 2 O 2 < PC < electro-Fenton (EF). This behaviour is given to the high oxidant character of the homogenous OH radicals generated by EF and PC approaches. The EO process with production of H 2 O 2 (EO-H 2 O 2 ) is limited by mass transport and the EC, as a separation method, takes longer times to achieve similar removal results. Energy requirements about 0.06 kWh g COD -1 , 0.09 kWh g COD -1 , 0.7 kWh g COD -1 and 0.1 kWh g COD -1 were achieved for PC, EF, EO-H 2 O 2 and EC, respectively. Degradation intermediates were monitored and carboxylic acids were detected for PC and EF processes, being rapidly removed by the former technology. PC emerges as a promising and competitive alternative for wastewaters depollution, among other oxidative approaches. Copyright © 2018 Elsevier Ltd. All rights reserved.
Optimization of Lyophilized Plasma for Use in Combat Casualties
2013-01-21
SD. (Fib: fibrinogen, FII: Factor II, FV: Factor V, FVII : Factor VII, FVIII: Factor VIII, FIX: Factor IX, FX: Factor X, FXI: Factor XI, FXII...coagulation factor activity. Twenty swine were anesthetized and subjected to a validated model of polytrauma and hemorrhagic shock. They were...to assess inflammatory markers. Major Findings: 50%LP had higher electrolyte concentrations, osmolarity, and increased coagulation factor activity
Organic pollutant removal from edible oil process wastewater using electrocoagulation
NASA Astrophysics Data System (ADS)
Sharma, S.; Can, O. T.; Hammed, M.; Nawarathna, D.; Simsek, H.
2018-03-01
Wastewaters generated from vegetable oil industries contain a high concentration of organic pollutants that are detrimental to the aquatic ecosystem. Electrochemical processes are gaining importance in the treatment of inorganic and resistant organic pollutants in wastewaters. In this study, electrocoagulation (EC) was applied to remove organic pollutants and oil and grease from canola oil wastewater using aluminum (Al) and iron (Fe) electrodes. The application of EC in the wastewater achieved more than 80% removal of organic carbon and nearly 100% removal of suspended solids (SS). The effectiveness of EC is influenced mainly by current density, pH, electrolyte (NaCl), electrode contact time and electrode type. It was observed that Al electrode combination yielded better removal at a lesser time compared to that of Fe electrodes. However, varying current densities had its significance in terms of coagulation time only. Increase in current density achieved decrease in coagulation time. Both Al and Fe could remove between 52-59% of oil and grease from canola oil wastewater
Smith, W Zachary; Harrison, Hannah B; Salhanick, Marc A; Higgins, Russell A; Ortiz, Alfonso; Olson, John D; Schwacha, Martin G; Harrison, Chantal R; Aydelotte, Jayson D; Stewart, Ronald M; Dent, Daniel L
2013-12-01
The evacuated hemothorax has been poorly described because it varies with time, it has been found to be incoagulable, and its potential effect on the coagulation cascade during autotransfusion is largely unknown. This is a prospective descriptive study of adult patients with traumatic chest injury necessitating tube thoracostomy. Pleural and venous samples were analyzed for coagulation, hematology, and electrolytes at 1 to 4 hours after drainage. Pleural samples were also analyzed for their effect on the coagulation cascade via mixing studies. Thirty-four subjects were enrolled with a traumatic hemothorax. The following measured coagulation factors were significantly depleted compared with venous blood: international normalized ratio (>9 vs 1.1) (P < .001) and activated partial thromboplastin time (aPTT) (>180 vs 24.5 seconds) (P < .001). Mixing studies showed a dose-dependent increase in coagulation dilutions through 1:8 (P < .05). An evacuated hemothorax does not vary in composition significantly with time and is incoagulable alone. Mixing studies with hemothorax plasma increased coagulation, raising safety concerns. Copyright © 2013 Elsevier Inc. All rights reserved.
Electrocoagulation in Water Treatment
NASA Astrophysics Data System (ADS)
Liu, Huijuan; Zhao, Xu; Qu, Jiuhui
Electrocoagulation (EC) is an electrochemical method of treating polluted water where sacrificial anodes corrode to release active coagulant precursors (usually aluminum or iron cations) into solution. At the cathode, gas evolves (usually as hydrogen bubbles) accompanying electrolytic reactions. EC needs simple equipments and is designable for virtually any size. It is cost effective and easily operable. Specially, the recent technical improvements combined with a growing need for small-scale water treatment facilities have led to a revaluation of EC. In this chapter, the basic principle of EC was introduced first. Following that, reactions at the electrodes and electrode assignment were reviewed; electrode passivation process and activation method were presented; comparison between electrocoagulation and chemical coagulation was performed; typical design of the EC reactors was also described; and factors affecting electrocoagulation including current density, effect of conductivity, temperature, and pH were introduced in details. Finally, application of EC in water treatment was given in details.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, S.W.; McCormick, J.B.
1984-09-01
Clinical specimens from patients infected with Lassa, Ebola, or Marburg virus may present a serious biohazard to laboratory workers. The authors have examined the effects of heat, alteration of pH, and gamma radiation on these viruses in human blood and on the electrolytes, enzymes, and coagulation factors measured in laboratory tests that are important in the care of an infected patient. Heating serum at 60 degrees C for 1 h reduced high titers of these viruses to noninfectious levels without altering the serum levels of glucose, blood urea nitrogen, and electrolytes. Dilution of blood in 3% acetic acid, diluent formore » a leukocyte count, inactivated all of these viruses. All of the methods tested for viral inactivation markedly altered certain serum proteins, making these methods unsuitable for samples that are to be tested for certain enzyme levels and coagulation factors.« less
Electrochemical removal of tannins from aqueous solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buso, A.; Balbo, L.; Giomo, M.
2000-02-01
The application of electrochemical methods to remove tannins from wastewater was investigated. Gallotannic acid was used as the reference substance. Electrochemical experiments were performed using platinum electrodes. Macroscale potentiostatic or galvanostatic electrolyses were carried out with sodium sulfate or sodium chloride as supporting electrolytes, to analyze direct and indirect oxidation processes. Operating variables such as pH and chloride concentration were considered to determine their influence on the efficiency and energy consumption of the process. The simulation of a pilot plant was carried out with a mathematical model, the parameters of which were determined by fitting of experimental profiles. The resultsmore » of a preliminary investigation on the oxidation-coagulation process using sacrificial electrodes are also reported.« less
Evaluation of the Treatment Process of Landfill Leachate Using the Toxicity Assessment Method
Qiu, Aifeng; Cai, Qiang; Zhao, Yuan; Guo, Yingqing; Zhao, Liqian
2016-01-01
Landfill leachate is composed of a complex composition with strong biological toxicity. The combined treatment process of coagulation and sedimentation, anaerobics, electrolysis, and aerobics was set up to treat landfill leachate. This paper explores the effect of different operational parameters of coagulation and sedimentation tanks and electrolytic cells, while investigating the combined process for the removal efficiency of physicochemical indices after processing the landfill leachate. Meanwhile, a battery of toxicity tests with Vibrio fischeri, zebrafish larvae, and embryos were conducted to evaluate acute toxicity and calculated the toxicity reduction efficiency after each treatment process. The combined treatment process resulted in a 100% removal efficiency of Cu, Cd and Zn, and a 93.50% and an 87.44% removal efficiency of Ni and Cr, respectively. The overall removal efficiency of chemical oxygen demand (COD), ammonium nitrogen (NH4+-N), and total nitrogen (TN) were 93.57%, 97.46% and 73.60%, respectively. In addition, toxicity test results showed that the acute toxicity of landfill leachate had also been reduced significantly: toxicity units (TU) decreased from 84.75 to 12.00 for zebrafish larvae, from 82.64 to 10.55 for zebrafish embryos, and from 3.41 to 0.63 for Vibrio fischeri. The combined treatment process was proved to be an efficient treatment method to remove heavy metals, COD, NH4+-N, and acute bio-toxicity of landfill leachate. PMID:28009808
Evaluation of the Treatment Process of Landfill Leachate Using the Toxicity Assessment Method.
Qiu, Aifeng; Cai, Qiang; Zhao, Yuan; Guo, Yingqing; Zhao, Liqian
2016-12-21
Landfill leachate is composed of a complex composition with strong biological toxicity. The combined treatment process of coagulation and sedimentation, anaerobics, electrolysis, and aerobics was set up to treat landfill leachate. This paper explores the effect of different operational parameters of coagulation and sedimentation tanks and electrolytic cells, while investigating the combined process for the removal efficiency of physicochemical indices after processing the landfill leachate. Meanwhile, a battery of toxicity tests with Vibrio fischeri , zebrafish larvae, and embryos were conducted to evaluate acute toxicity and calculated the toxicity reduction efficiency after each treatment process. The combined treatment process resulted in a 100% removal efficiency of Cu, Cd and Zn, and a 93.50% and an 87.44% removal efficiency of Ni and Cr, respectively. The overall removal efficiency of chemical oxygen demand (COD), ammonium nitrogen (NH₄⁺-N), and total nitrogen (TN) were 93.57%, 97.46% and 73.60%, respectively. In addition, toxicity test results showed that the acute toxicity of landfill leachate had also been reduced significantly: toxicity units (TU) decreased from 84.75 to 12.00 for zebrafish larvae, from 82.64 to 10.55 for zebrafish embryos, and from 3.41 to 0.63 for Vibrio fischeri . The combined treatment process was proved to be an efficient treatment method to remove heavy metals, COD, NH₄⁺-N, and acute bio-toxicity of landfill leachate.
Treatment of oily wastewater of a gas refinery by electrocoagulation using aluminum electrodes.
Saeedi, Mohesn; Khalvati-Fahlyani, Amin
2011-03-01
Oily wastewaters are the most important discharges of gas refineries from an environmental point-of-view. In the present study, treatment of gas refinery oily wastewater by electrocoagulation using aluminum electrodes was investigated. The effects of electrode distance, initial pH, sodium sulfate (Na2SO4) as a supporting electrolyte, polyaluminum chloride dosage as a coagulant aid, and current density on the efficiency of chemical oxygen demand (COD) removal were examined. The results revealed that the COD removal rate increases by applying more current density and polyaluminum chloride and, to a lesser extent, Na2SO4 dosage. The results also showed that 97% COD can be removed at optimum operational conditions. Specific electrical energy consumption could be reduced from 19.48 kWh (kg COD removal)(-1) to 11.057 kWh (kg COD removal)(-1) using Na2SO4 as a supporting electrolyte. Gas chromatographic analysis of raw and treated wastewater also revealed that most normal hydrocarbons (nearly 99%) were removed during the electrocoagulation process.
Bench-to-bedside review: Rhabdomyolysis – an overview for clinicians
Huerta-Alardín, Ana L; Varon, Joseph; Marik, Paul E
2005-01-01
Rhabdomyolysis ranges from an asymptomatic illness with elevation in the creatine kinase level to a life-threatening condition associated with extreme elevations in creatine kinase, electrolyte imbalances, acute renal failure and disseminated intravascular coagulation. Muscular trauma is the most common cause of rhabdomyolysis. Less common causes include muscle enzyme deficiencies, electrolyte abnormalities, infectious causes, drugs, toxins and endocrinopathies. Weakness, myalgia and tea-colored urine are the main clinical manifestations. The most sensitive laboratory finding of muscle injury is an elevated plasma creatine kinase level. The management of patients with rhabdomyolysis includes early vigorous hydration. PMID:15774072
Treatment of dairy effluents by electrocoagulation using aluminium electrodes.
Tchamango, Serge; Nanseu-Njiki, Charles P; Ngameni, Emmanuel; Hadjiev, Dimiter; Darchen, André
2010-01-15
This work sets out to examine the efficiency of an electrolytic treatment: electrocoagulation, applied to dairy effluents. The experiments were carried out using a soluble aluminium anode on artificial wastewater derived from solutions of milk powder. The flocks generated during this treatment were separated by filtration. The analysis of the filtrates showed that the chemical oxygen demand (COD) was reduced by up to 61% while the removal of phosphorus, nitrogen contents, and turbidity were 89, 81 and 100%, respectively. An analogous treatment applied to phosphate and lactose solutions revealed that lactose was not eliminated, a fact that could account for the rather poor lowering of the COD. Compared to the chemical coagulation treatment with aluminium sulphate, the efficiency of the electrocoagulation technique was almost identical. However the wastewaters treated by electrocoagulation differed by the fact that they exhibited a lower conductivity and a neutral pH value (by contrast to the acid nature of the solution treated by the chemical coagulation). This result (low conductivity, neutral pH) tends to show that it may be possible to recycle the treated water for some industrial uses. Moreover, the electrocoagulation process uses fewer reagents: the mass of the aluminium anode dissolved during the treatment is lower compared to the quantity of the aluminium salt used in chemical coagulation. These two observations clearly show that the electrocoagulation technique is more performing. Copyright 2009 Elsevier B.V. All rights reserved.
Wang, Lixin; Yang, Xuezhi; Wang, Qi; Zeng, Yuxuan; Ding, Lei; Jiang, Wei
2017-01-01
The aggregation and deposition of carbon nanotubes (CNTs) determines their transport and fate in natural waters. Therefore, the aggregation kinetics of humic-acid treated multi-walled carbon nanotubes (HA-MWCNTs) was investigated by time-resolved dynamic light scattering in NaCl and CaCl 2 electrolyte solutions. Increased ionic strength induced HA-MWCNT aggregation due to the less negative zeta potential and the reduced electrostatic repulsion. The critical coagulation concentration (CCC) values of HA-MWCNTs were 80mmol/L in NaCl and 1.3mmol/L in CaCl 2 electrolyte, showing that Ca 2+ causes more serious aggregation than Na + . The aggregation behavior of HA-MWCNTs was consistent with Derjaguin-Landau-Verwey-Overbeek theory. The deposition kinetics of HA-MWCNTs was measured by the optical absorbance at 800nm. The critical deposition concentrations for HA-MWCNT in NaCl and CaCl 2 solutions were close to the CCC values, therefore the rate of deposition cannot be increased by changing the ionic strength in the diffusion-limited aggregation regime. The deposition process was correlated to the aggregation since larger aggregates increased gravitational deposition and decreased random Brownian diffusion. HA-MWCNTs hydrodynamic diameters were evaluated at 5, 15 and 25°C. Higher temperature caused faster aggregation due to the reduced electrostatic repulsion and increased random Brownian motion and collision frequency. HA-MWCNTs aggregate faster at higher temperature in either NaCl or CaCl 2 electrolyte due to the decreased electrostatic repulsion and increased random Brownian motion. Our results suggest that CNT aggregation and deposition are two correlated processes governed by the electrolyte, and CNT transport is favored at low ionic strength and low temperature. Copyright © 2016. Published by Elsevier B.V.
Pheochromocytoma presenting with rhabdomyolysis and acute renal failure: a case report.
Celik, Huseyin; Celik, Ozlem; Guldiken, Sibel; Inal, Volkan; Puyan, Fulya Oz; Tugrul, Armagan
2014-02-01
Rhabdomyolysis ranges from an asymptomatic illness with elevated creatine kinase levels to a life-threatening condition associated with extreme elevations in creatine kinase, electrolyte imbalances, acute renal failure, and disseminated intravascular coagulation. The most common causes are crush injury, overexertion, alcohol abuse, certain medicines, and toxic substances. A number of electrolyte abnormalities and endocrinopathies, including hypothyroidism, thyrotoxicosis, diabetic ketoacidosis, nonketotic hyperosmolar state, and hyperaldosteronism, cause rhabdomyolysis. Rhabdomyolysis and acute renal failure are unusual manifestations of pheochromocytoma. There are a few case reports with pheochromocytoma presenting rhabdomyolysis and acute renal failure. Herein, we report a case with pheochromocytoma crisis presenting with rhabdomyolysis and acute renal failure.
Lei, Kin Fong; Chen, Kuan-Hao; Tsui, Po-Hsiang; Tsang, Ngan-Ming
2013-01-01
Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity. PMID:24116099
A new approach using coagulation rate constant for evaluation of turbidity removal
NASA Astrophysics Data System (ADS)
Al-Sameraiy, Mukheled
2017-06-01
Coagulation-flocculation-sedimentation processes for treating three levels of bentonite synthetic turbid water using date seeds (DS) and alum (A) coagulants were investigated in the previous research work. In the current research, the same experimental results were used to adopt a new approach on a basis of using coagulation rate constant as an investigating parameter to identify optimum doses of these coagulants. Moreover, the performance of these coagulants to meet (WHO) turbidity standard was assessed by introducing a new evaluating criterion in terms of critical coagulation rate constant (kc). Coagulation rate constants (k2) were mathematically calculated in second order form of coagulation process for each coagulant. The maximum (k2) values corresponded to doses, which were obviously to be considered as optimum doses. The proposed criterion to assess the performance of coagulation process of these coagulants was based on the mathematical representation of (WHO) turbidity guidelines in second order form of coagulation process stated that (k2) for each coagulant should be ≥ (kc) for each level of synthetic turbid water. For all tested turbid water, DS coagulant could not satisfy it. While, A coagulant could satisfy it. The results obtained in the present research are exactly in agreement with the previous published results in terms of finding optimum doses for each coagulant and assessing their performances. On the whole, it is recommended considering coagulation rate constant to be a new approach as an indicator for investigating optimum doses and critical coagulation rate constant to be a new evaluating criterion to assess coagulants' performance.
Effects of Temperature on Aggregation Kinetics of Graphene Oxide in Aqueous Solutions
NASA Astrophysics Data System (ADS)
Wang, M.; Gao, B.; Tang, D.; Sun, H.; Yin, X.; Yu, C.
2017-12-01
Temperature may play an important role in controlling graphene oxide (GO) stability in aqueous solutions, but it has been overlooked in the literature. In this work, laboratory experiments were conducted to determine the effects of temperature (6, 25, and 40 °C) on GO aggregation kinetics under different combinations of ionic strength, cation type, humic acid (HA) concentration by monitoring GO hydrodynamic radii and attachment efficiencies. The results showed that, without HA, temperature increase promoted GO aggregation in both monovalent (Na+ and K+) and divalent (Ca2+) solutions. This phenomenon might be caused by multiple processes including enhanced collision frequency, enhanced cation dehydration, and reduced electrostatic repulsion. The presence of HA introduced steric repulsion forces that enhanced GO stability and temperature showed different effects GO aggregation kinetics in monovalent and divalent electrolytes. In monovalent electrolytes, cold temperature diminished the steric repulsion of HA-coated GO. As a result, the fastest increasing rate of GO hydrodynamic radius and the smallest critical coagulation concentration value appeared at the lowest temperature (6 °C). Conversely, in divalent electrolyte solutions with HA, high temperate favored GO aggregation, probably because the interactions between Ca2+ and HA increased with temperature resulting in lower HA coating on GO. Findings of this work emphasized the importance of temperature as well as solution chemistry on the stability and fate of GO nanoparticles in aquatic environment.
The future for electrocoagulation as a localised water treatment technology.
Holt, Peter K; Barton, Geoffrey W; Mitchell, Cynthia A
2005-04-01
Electrocoagulation is an electrochemical method of treating polluted water whereby sacrificial anodes corrode to release active coagulant precursors (usually aluminium or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles) at the cathode. Electrocoagulation has a long history as a water treatment technology having been employed to remove a wide range of pollutants. However electrocoagulation has never become accepted as a 'mainstream' water treatment technology. The lack of a systematic approach to electrocoagulation reactor design/operation and the issue of electrode reliability (particularly passivation of the electrodes over time) have limited its implementation. However recent technical improvements combined with a growing need for small-scale decentralised water treatment facilities have led to a re-evaluation of electrocoagulation. Starting with a review of electrocoagulation reactor design/operation, this article examines and identifies a conceptual framework for electrocoagulation that focuses on the interactions between electrochemistry, coagulation and flotation. In addition detailed experimental data are provided from a batch reactor system removing suspended solids together with a mathematical analysis based on the 'white water' model for the dissolved air flotation process. Current density is identified as the key operational parameter influencing which pollutant removal mechanism dominates. The conclusion is drawn that electrocoagulation has a future as a decentralised water treatment technology. A conceptual framework is presented for future research directed towards a more mechanistic understanding of the process.
Bedekar, Priyanka A; Bhalkar, Bhumika N; Patil, Swapnil M; Govindwar, Sanjay P
2016-10-01
Generation of secondary sludge is a major concern of textile dye removal by coagulation process. Combinatorial coagulation-biodegradation treatment system has been found efficient in degradation of coagulated textile dye sludge. Moringa oleifera seed powder (700 mg L -1 ) was able to coagulate textile dyestuff from real textile wastewater with 98 % color removal. Novel consortium-BBA was found to decolorize coagulated dye sludge. Parameters that significantly affect coagulation process were optimized using response surface methodology. The bench-scale stirred tank reactor (50-L capacity) designed with optimized parameters for coagulation process could efficiently remove 98, 89, 78, and 67 % of American Dye Manufacturer's Institute (ADMI) in four repetitive cycles, respectively. Solid-state fermentation composting reactor designed to treat coagulated dye sludge showed 96 % removal of dye within 10 days. Coagulation of dyes from textile wastewater and degradation of coagulated dye sludge were confirmed by Fourier transform infrared spectroscopy (FTIR) analysis. Cell morphology assay, comet assay, and phytotoxicity confirmed the formation of less toxic products after coagulation and degradation mechanism.
Enhancement of Chlorella vulgaris harvesting via the electro-coagulation-flotation (ECF) method.
Wong, Y K; Ho, Y H; Leung, H M; Ho, K C; Yau, Y H; Yung, K K L
2017-04-01
This article explores the potential of using an electro-coagulation-flotation (ECF) harvester to allow flotation of microalgae cells for surface harvesting. A response surface methodology (RSM) model was used to optimize ECF harvesting by adjusting electrode plate material, electrode plate number, charge of the electrodes, electrolyte concentration, and pH value of the culture solution. The result revealed that three aluminum electrode plates (one anode and two cathodes), brine solution (8 g/L), and acidity (pH = 4) of culture solution (optimized ECF harvester) The highest flocculant concentration was measured at 2966 mg/L after 60 min and showed a 79.8 % increase of flocculation concentration. Such results can provide a basis for designing a large-scale microalgae harvester for commercial use in the future.
An updated concept of coagulation with clinical implications.
Romney, Gregory; Glick, Michael
2009-05-01
Over the past century, a series of models have been put forth to explain the coagulation mechanism. The coagulation cascade/waterfall model has gained the most widespread acceptance. This model, however, has problems when it is used in different clinical scenarios. A more recently proposed cell-based model better describes the coagulation process in vivo and provides oral health care professionals (OHCPs) with a better understanding of the clinical implications of providing dental care to patients with potentially increased bleeding tendencies. The authors conducted a literature search using the PubMed database. They searched for key words including "coagulation," "hemostasis," "bleeding," "coagulation factors," "models," "prothrombin time," "activated partial thromboplastin time," "international normalized ratio," "anticoagulation therapy" and "hemophilia" separately and in combination. The coagulation cascade/waterfall model is insufficient to explain coagulation in vivo, predict a patient's bleeding tendency, or correlate clinical outcomes with specific laboratory screening tests such as prothrombin time, activated partial thromboplastin time and international normalized ratio. However, the cell-based model of coagulation that reflects the in vivo process of coagulation provides insight into the clinical ramifications of treating dental patients with specific coagulation factor deficiencies. Understanding the in vivo coagulation process will help OHCPs better predict a patient's bleeding tendency. In addition, applying the theoretical concept of the cell-based model of coagulation to commonly used laboratory screening tests for coagulation and bleeding will result in safer and more appropriate dental care.
Chu, Wen-Hai; Gao, Nai-Yun; Templeton, Michael R; Yin, Da-Qiang
2011-04-01
The formation of disinfection by-products (DBPs), including both nitrogenous disinfection by-products (N-DBPs) and carbonaceous disinfection by-products (C-DBPs), was investigated upon chlorination of water samples following two treatment processes: (i) coagulation-inclined plate sedimentation (IPS)-filtration and (ii) coagulation-dissolved air flotation (DAF)-filtration. The removal of algae, dissolved organic nitrogen (DON), dissolved organic carbon (DOC) and UV(254) by coagulation-DAF-filtration was superior to coagulation-IPS-filtration. On average, 53%, 53% and 31% of DOC, DON and UV(254) were removed by coagulation-DAF-filtration process, which were higher than 47%, 31% and 27% of that by coagulation-IPS-filtration process. Additionally, coagulation-IPS-filtration performed less well at removing the low molecular weight organics than coagulation-DAF-filtration process. The concentrations of chloroform, dichloroacetamide (DCAcAm) and dichloroacetonitrile (DCAN) formed during chlorination after coagulation-DAF-filtration reached their maximum values of 13, 1.5 and 4.7μgL(-1), respectively, and were lower than those after coagulation-IPS-filtration with the maximum detected levels of 17, 2.9 and 6.3μgL(-1). However, the trichloronitromethane (TCNM) concentration after the two processes was similar, suggesting that DON may have less of a contribution to TCNM formation than DCAcAm and DCAN. Copyright © 2011 Elsevier Ltd. All rights reserved.
Gille, Jochen; Sablotzki, Armin; Malcharek, Michael; Raff, Thomas; Mogk, Martin; Parentin, Torsten
2014-12-01
For critically ill patients, the use of regional citrate anticoagulation as part of continuous renal replacement therapy (CRRT) has become increasingly common in recent years. However, there are scarce data on the use of this technique in patients with burns. The aim of this study was to examine the effectiveness, feasibility and complications of regional citrate anticoagulation for CRRT in burn patients, as well as the effects on coagulation and the electrolyte and acid-base balance. This retrospective study included all patients who received renal replacement therapy with citrate anticoagulation to treat acute kidney injury (AKI) between January 1, 2004 and December 31, 2009 at the burn unit of St. Georg Hospital GmbH in Leipzig. During the examination period, 18 patients were treated using CRRT with regional citrate anticoagulation (CVVHDF in the pre-dilution mode). The median patient age was 64 years (49.5; 71), with a median TBSA of 42.5% (33.25; 52.5) and a median ABSI score of 10 (9; 10). The CRRT was initiated on a median of 6 days (4; 8.75) after admission to the hospital and continued for a median duration of 7 days (5; 8). The median dialysis dose was 38.2mlkgBW(-1)h(-1) (31.8; 42.1). The median effective filter operation time was 67h (46; 72). No relevant disorders associated with acid-base balance, electrolytes or coagulation occurred, and there were no bleeding complications. In terms of bleeding risk and electrolyte and acid-base balance, regional citrate anticoagulation may be considered to be an effective, safe and user-friendly procedure for patients with severe burns and AKI. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Zhan, Xiao; Gao, Bao-yu; Liu, Bin; Xu, Chun-hua; Yue, Qin-yan
2010-05-01
Two types of inorganic polymer coagulants, polyferric chloride (PFC) and polyaluminum chloride (PAC), were chosen to treat the Yellow River water. Different dosages were investigated in order to investigate the turbidity, UV24, DOC and permanganate index removal efficiency and their coagulation mechanisms based on the Zeta potentials. The natural organic matter removal by the combination of coagulation and adsorption with powder activated carbon were analyzed based on different coagulant and adsorbent dosages and dosing orders. The effects of combination of coagulation and adsorption on the residual chlorine decay were analyzed. The results showed that the two coagulants had high turbidity removal efficiency ( > 90%). The UV254, DOC, permanganate index removal efficiency were 29.2%, 26.1% and 27.9% respectively for PAC coagulation and were 32.3%, 23.3% and 32.9% respectively for PFC. Electric neutralization played an important role in the PAC coagulation process while both adsorption bridging and electric neutralization performed when PFC was used. The removal percentage of organic matter increased with the increase coagulant and adsorbent. The adsorption after coagulation process gave the better UV254 and DOC removal efficiency than the coagulation after adsorption. The UV254 and DOC removal efficiency were 95.2% and 99.9% for PAC coagulation after adsorption and were 90.1% and 99.9% for PFC coagulation first. But adding powder activated carbon can improve floc settlement performance and maintained persistent disinfection effect.
Mosaddeghi, Mohammad Reza; Pajoum Shariati, Farshid; Vaziri Yazdi, Seyed Ali; Nabi Bidhendi, Gholamreza
2018-06-21
The wastewater produced in a pulp and paper industry is one of the most polluted industrial wastewaters, and therefore its treatment requires complex processes. One of the simple and feasible processes in pulp and paper wastewater treatment is coagulation and flocculation. Overusing a chemical coagulant can produce a large volume of sludge and increase costs and health concerns. Therefore, the use of natural and plant-based coagulants has been recently attracted the attention of researchers. One of the advantages of using Ocimum basilicum as a coagulant is a reduction in the amount of chemical coagulant required. In this study, the effect of basil mucilage has been investigated as a plant-based coagulant together with alum for treatment of paper recycling wastewater. Response surface methodology (RSM) was used to optimize the process of chemical coagulation based on a central composite rotatable design (CCRD). Quadratic models for colour reduction and TSS removal with coefficients of determination of R 2 >96 were obtained using the analysis of variance. Under optimal conditions, removal efficiencies of colour and total suspended solids (TSS) were 85% and 82%, respectively.
Prediction of coagulation and flocculation processes using ANN models and fuzzy regression.
Zangooei, Hossein; Delnavaz, Mohammad; Asadollahfardi, Gholamreza
2016-09-01
Coagulation and flocculation are two main processes used to integrate colloidal particles into larger particles and are two main stages of primary water treatment. Coagulation and flocculation processes are only needed when colloidal particles are a significant part of the total suspended solid fraction. Our objective was to predict turbidity of water after the coagulation and flocculation process while other parameters such as types and concentrations of coagulants, pH, and influent turbidity of raw water were known. We used a multilayer perceptron (MLP), a radial basis function (RBF) of artificial neural networks (ANNs) and various kinds of fuzzy regression analysis to predict turbidity after the coagulation and flocculation processes. The coagulant used in the pilot plant, which was located in water treatment plant, was poly aluminum chloride. We used existing data, including the type and concentrations of coagulant, pH and influent turbidity, of the raw water because these types of data were available from the pilot plant for simulation and data was collected by the Tehran water authority. The results indicated that ANNs had more ability in simulating the coagulation and flocculation process and predicting turbidity removal with different experimental data than did the fuzzy regression analysis, and may have the ability to reduce the number of jar tests, which are time-consuming and expensive. The MLP neural network proved to be the best network compared to the RBF neural network and fuzzy regression analysis in this study. The MLP neural network can predict the effluent turbidity of the coagulation and the flocculation process with a coefficient of determination (R 2 ) of 0.96 and root mean square error of 0.0106.
Sillanpää, Mika; Ncibi, Mohamed Chaker; Matilainen, Anu; Vepsäläinen, Mikko
2018-01-01
Natural organic matter (NOM) is a complex matrix of organic substances produced in (or channeled to) aquatic ecosystems via various biological, geological and hydrological cycles. Such variability is posing a serious challenge to most water treatment technologies, especially the ones designed to treat drinking water supplies. Lately, in addition to the fluctuating composition of NOM, a substantial increase of its concentration in fresh waters, and also municipal wastewater effluents, has been reported worldwide, which justifies the urgent need to develop highly efficient and versatile water treatment processes. Coagulation is among the most applied processes for water and wastewater treatment. The application of coagulation to remove NOM from drinking water supplies has received a great deal of attention from researchers around the world because it was efficient and helped avoiding the formation of disinfection by products (DBPs). Nonetheless, with the increased fluctuation of NOM in water (concentration and composition), the efficiency of conventional coagulation was substantially reduced, hence the need to develop enhanced coagulation processes by optimizing the operating conditions (mainly the amount coagulants and pH), developing more efficient inorganic or organic coagulants, as well as coupling coagulation with other water treatment technologies. In the present review, recent research studies dealing with the application of coagulation for NOM removal from drinking water supplies are presented and compared. In addition, integration schemes combining coagulation and other water treatment processes are presented, including membrane filtration, oxidation, adsorption and others processes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Shin, D H; Shin, W S; Kim, Y H; Han, Myung Ho; Choi, S J
2006-01-01
A combined process consisted of a Moving-Bed Biofilm Reactor (MBBR) and chemical coagulation was investigated for textile wastewater treatment. The pilot scale MBBR system is composed of three MBBRs (anaerobic, aerobic-1 and aerobic-2 in series), each reactor was filled with 20% (v/v) of polyurethane-activated carbon (PU-AC) carrier for biological treatment followed by chemical coagulation with FeCl2. ln the MBBR process, 85% of COD and 70% of color (influent COD = 807.5 mg/L and color = 3,400 PtCo unit) were removed using relatively low MLSS concentration and short hydraulic retention time (HRT = 44 hr). The biologically treated dyeing wastewater was subjected to chemical coagulation. After coagulation with FeCl2, 95% of COD and 97% of color were removed overall. The combined process of MBBR and chemical coagulation has promising potential for dyeing wastewater treatment.
Amuda, O S; Amoo, I A; Ajayi, O O
2006-02-28
This study investigated the effect of coagulation/flocculation treatment process on wastewater of Fumman Beverage Industry, Ibadan, Nigeria. The study also compared different dosages of coagulant, polyelectrolyte (non-ionic polyacrylamide) and different pH values of the coagulation processes. The effect of different dosages of polyelectrolyte in combination with coagulant was also studied. The results reveal that low pH values (3-8), enhance removal efficiency of the contaminants. Percentage removal of 78, 74 and 75 of COD, TSS and TP, respectively, were achieved by the addition of 500 mg/L Fe2(SO4)3.3H2O and 93, 94 and 96% removal of COD, TSS and TP, respectively, were achieved with the addition of 25 mg/L polyelectrolyte to the coagulation process. The volume of sludge produced, when coagulant was used solely, was higher compared to the use of polyelectrolyte combined with Fe2(SO4)3.3H2O. This may be as a result of non-ionic nature of the polyelectrolyte; hence, it does not chemically react with solids of the wastewater. Coagulation/flocculation may be useful as a pre-treatment process for beverage industrial wastewater prior to biological treatment.
Application of alum and chickpea (cicer arietinum) in removing color from leachate
NASA Astrophysics Data System (ADS)
Zin, N. S. M.; Awang, N. H.; Akbar, N. A.
2018-04-01
Dual coagulant has the potential to improve the coagulation process. In leachate treatment coagulation/flocculation can be used as a main treatment method or as a polishing/tertiary treatment step. Application of natural coagulant as coagulant aids able to increase the formation of floc and the removal ability of the coagulation process. This study was focusing on the ability of dual coagulants made from chemical coagulant (Alum) and natural coagulant (Cicer Arietinum (CA)) in removing colour from leachate. Jar test was carried out to investigate the effect of dose and pH on the removal ability of the dual coagulant. The optimum pH and dose for dual coagulant were obtained at pH 6.0 with dose of Alum at 4 g/L and dose of CA at 0.6 g/L with 94% removal of colour. While the optimum removal of colour for single Alum (4 g/L) and single CA (1.4 g/L) were recorded as 88% and 22%, respectively. The removals obtained using single natural and chemical coagulants were not as good as those obtained by dual coagulant. Thus, addition of CA as a coagulant aid for alum, able to increase the removal of color from leachate and has the potential to be applied as a treatment method for leachate.
Effects of water chemistry on arsenic removal from drinking water by electrocoagulation.
Wan, Wei; Pepping, Troy J; Banerji, Tuhin; Chaudhari, Sanjeev; Giammar, Daniel E
2011-01-01
Exposure to arsenic through drinking water poses a threat to human health. Electrocoagulation is a water treatment technology that involves electrolytic oxidation of anode materials and in-situ generation of coagulant. The electrochemical generation of coagulant is an alternative to using chemical coagulants, and the process can also oxidize As(III) to As(V). Batch electrocoagulation experiments were performed in the laboratory using iron electrodes. The experiments quantified the effects of pH, initial arsenic concentration and oxidation state, and concentrations of dissolved phosphate, silica and sulfate on the rate and extent of arsenic removal. The iron generated during electrocoagulation precipitated as lepidocrocite (γ-FeOOH), except when dissolved silica was present, and arsenic was removed by adsorption to the lepidocrocite. Arsenic removal was slower at higher pH. When solutions initially contained As(III), a portion of the As(III) was oxidized to As(V) during electrocoagulation. As(V) removal was faster than As(III) removal. The presence of 1 and 4 mg/L phosphate inhibited arsenic removal, while the presence of 5 and 20 mg/L silica or 10 and 50 mg/L sulfate had no significant effect on arsenic removal. For most conditions examined in this study, over 99.9% arsenic removal efficiency was achieved. Electrocoagulation was also highly effective at removing arsenic from drinking water in field trials conducted in a village in Eastern India. By using operation times long enough to produce sufficient iron oxide for removal of both phosphate and arsenate, the performance of the systems in field trials was not inhibited by high phosphate concentrations. Copyright © 2010 Elsevier Ltd. All rights reserved.
Overview of the coagulation system.
Palta, Sanjeev; Saroa, Richa; Palta, Anshu
2014-09-01
Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms 'coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.
Overview of the coagulation system
Palta, Sanjeev; Saroa, Richa; Palta, Anshu
2014-01-01
Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ‘coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same. PMID:25535411
Analysis and optimization of coagulation and flocculation process
NASA Astrophysics Data System (ADS)
Saritha, V.; Srinivas, N.; Srikanth Vuppala, N. V.
2017-03-01
Natural coagulants have been the focus of research of many investigators through the last decade owing to the problems caused by the chemical coagulants. Optimization of process parameters is vital for the effectiveness of coagulation process. In the present study optimization of parameters like pH, dose of coagulant and mixing speed were studied using natural coagulants sago and chitin in comparison with alum. Jar test apparatus was used to perform the coagulation. The results showed that the removal of turbidity was up to 99 % by both alum and chitin at lower doses of coagulant, i.e., 0.1-0.3 g/L, whereas sago has shown a reduction of 70-100 % at doses of 0.1 and 0.2 g/L. The optimum conditions observed for sago were 6 and 7 whereas chitin was stable at all pH ranges, lower coagulant doses, i.e., 0.1-0.3 g/L and mixing speed—rapid mixing at 100 rpm for 10 min and slow mixing 20 rpm for 20 min. Hence, it can be concluded that sago and chitin can be used for treating water even with large seasonal variation in turbidity.
A Review on Adsorption of Fluoride from Aqueous Solution
Habuda-Stanić, Mirna; Ergović Ravančić, Maja; Flanagan, Andrew
2014-01-01
Fluoride is one of the anionic contaminants which is found in excess in surface or groundwater because of geochemical reactions or anthropogenic activities such as the disposal of industrial wastewaters. Among various methods used for defluoridation of water such as coagulation, precipitation, membrane processes, electrolytic treatment, ion-exchange, the adsorption process is widely used. It offers satisfactory results and seems to be a more attractive method for the removal of fluoride in terms of cost, simplicity of design and operation. Various conventional and non-conventional adsorbents have been assessed for the removal of fluoride from water. In this review, a list of various adsorbents (oxides and hydroxides, biosorbents, geomaterials, carbonaceous materials and industrial products and by-products) and its modifications from literature are surveyed and their adsorption capacities under various conditions are compared. The effect of other impurities on fluoride removal has also been discussed. This survey showed that various adsorbents, especially binary and trimetal oxides and hydroxides, have good potential for the fluoride removal from aquatic environments. PMID:28788194
Management of patients with risk factors
Waldfahrer, Frank
2013-01-01
This review addresses concomitant diseases and risk factors in patients treated for diseases of the ears, nose and throat in outpatient and hospital services. Besides heart disease, lung disease, liver disease and kidney disease, this article also covers disorders of coagulation (including therapy with new oral anticoagulants) and electrolyte imbalance. Special attention is paid to the prophylaxis, diagnosis and treatment of perioperative delirium. It is also intended to help optimise the preparation for surgical procedures and pharmacotherapy during the hospital stay. PMID:24403970
In Vitro Assessment of Nanoparticle Effects on Blood Coagulation.
Potter, Timothy M; Rodriguez, Jamie C; Neun, Barry W; Ilinskaya, Anna N; Cedrone, Edward; Dobrovolskaia, Marina A
2018-01-01
Blood clotting is a complex process which involves both cellular and biochemical components. The key cellular players in the blood clotting process are thrombocytes or platelets. Other cells, including leukocytes and endothelial cells, contribute to clotting by expressing the so-called pro-coagulant activity (PCA) complex on their surface. The biochemical component of blood clotting is represented by the plasma coagulation cascade, which includes plasma proteins also known as coagulation factors. The coordinated interaction between platelets, leukocytes, endothelial cells, and plasma coagulation factors is necessary for maintaining hemostasis and for preventing excessive bleeding. Undesirable activation of all or some of these components may lead to pathological blood coagulation and life-threatening conditions such as consumptive coagulopathy or disseminated intravascular coagulation (DIC). In contrast, unintended inhibition of the coagulation pathways may lead to hemorrhage. Thrombogenicity is the property of a test material to induce blood coagulation by affecting one or more elements of the clotting process. Anticoagulant activity refers to the property of a test material to inhibit coagulation. The tendency to cause platelet aggregation, perturb plasma coagulation, and induce leukocyte PCA can serve as an in vitro measure of a nanomaterial's likelihood to be pro- or anticoagulant in vivo. This chapter describes three procedures for in vitro analyses of platelet aggregation, plasma coagulation time, and activation of leukocyte PCA. Platelet aggregation and plasma coagulation procedures have been described earlier. The revision here includes updated details about nanoparticle sample preparation, selection of nanoparticle concentration for the in vitro study, and updated details about assay controls. The chapter is expanded to describe a method for the leukocyte PCA analysis and case studies demonstrating the performance of these in vitro assays.
Akhunzada, Naveed Zaman; Tariq, Muhammad Bilal; Khan, Saad Akhtar; Sattar, Sidra; Tariq, Wajeeha; Shamim, Muhammad Shahzad; Dogar, Samie Asghar
2018-05-03
Routine preoperative blood testing has become a dogma. The general practice is to order preoperative workup as a knee-jerk response rather than individualize it for each patient. The fact that the bleeding brain tends to swell, which coupled with limited options for proximal control, packing, and overall hemostasis, leads to an overemphasis on the preoperative coagulation profile. This is a retrospective review of the medical records of patients admitted at Aga Khan University Hospital from January 2010 to December 2015 for an elective craniotomy. The hospital registry was used to identify files for review. Data were collected on a predefined proforma. A nationwide survey was performed, and 30 neurosurgery centers were contacted across Pakistan to confirm the practice of preoperative workup. The survey revealed that all centers had a similar practice of preoperative workup. This included complete blood count, serum electrolytes, and coagulation profile, including prothrombin time, activated partial thromboplastin time (aPTT), and international normalized ratio (INR). A total of 1800 files were reviewed. Nine (0.5%) patients were found to have deranged clotting profile without any predictive history of clotting derangement; 56% were male and 44% were female. Median age was 32 years with an interquartile range of 27 years. Median aPTT was (40.8 with 20.8 IQR). Median INR was (1.59 with 0.48 IQR). Median blood loss was (400 with 50 IQR). No significant association between coagulation profile (aPTT, INR) and blood loss was found (P = 0.85, r = -0.07). We conclude that patients without a history of coagulopathy and normal physical examination do not require routine coagulation screening before elective craniotomy. Copyright © 2018 Elsevier Inc. All rights reserved.
Performance of ultrafiltration membrane process combined with coagulation/sedimentation.
Jang, N Y; Watanabe, Y; Minegishi, S
2005-01-01
Effects of coagulation/sedimentation as a pre-treatment on the dead-end ultrafiltration (UF) membrane process were studied in terms of membrane fouling and removal efficiency of natural dissolved organic matter, using Chitose River water. Two types of experiment were carried out. One was a bench scale membrane filtration with jar-test and the other was membrane filtration pilot plant combined with the Jet Mixed Separator (JMS) as a pre-coagulation/sedimentation unit. In the bench scale experiment, the effects of coagulant dosage, pH and membrane operating pressure on the membrane fouling and removal efficiency of natural dissolved organic matter were investigated. In the pilot plant experiment, we also investigated the effect of pre-coagulation/sedimentation on the membrane fouling and the removal efficiency of natural dissolved organic matter. Coagulation/sedimentation prior to membrane filtration process controlled the membrane fouling and increased the removal efficiency of natural dissolved organic matter.
Colloidal Stability in Asymmetric Electrolytes: Modifications of the Schulze-Hardy Rule.
Trefalt, Gregor; Szilagyi, Istvan; Téllez, Gabriel; Borkovec, Michal
2017-02-21
The Schulze-Hardy rule suggests a strong dependence of the critical coagulation concentration (CCC) on the ionic valence. This rule is addressed theoretically and confronted with recent experimental results. The commonly presented derivation of this rule assumes symmetric electrolytes and highly charged particles. Both assumptions are incorrect. Symmetric electrolytes containing multivalent ions are hardly soluble, and experiments are normally carried out with the well-soluble salts of asymmetric electrolytes containing monovalent and multivalent ions. In this situation, however, the behavior is completely different whether the multivalent ions represent the counterions or co-ions. When these ions represent the counterions, meaning that the multivalent ions have the opposite sign than the charge of the particle, they adsorb strongly to the particles. Thereby, they progressively reduce the magnitude of the surface charge with increasing valence. In fact, this dependence of the charge density on the counterion valence is mainly responsible for the decrease of the CCC with the valence. In the co-ion case, where the multivalent ions have the same sign as the charge of the particle, the multivalent ions are repelled from the particles, and the surfaces remain highly charged. In this case, the inverse Schulze-Hardy rule normally applies, whereby the CCC varies inversely proportional to the co-ion valence.
Ding, An; Wang, Jinlong; Lin, Dachao; Tang, Xiaobin; Cheng, Xiaoxiang; Li, Guibai; Ren, Nanqi; Liang, Heng
2017-12-01
Gravity-driven membrane filtration systems are promising for decentralized sewage treatment due to their low energy consumption and low maintenance. However, the low stable permeability/flux is currently limiting their wider application. With the ultimate goal of increasing permeability, the aim of this study was to evaluate the effect of coagulation (in situ coagulation and pre-coagulation) on the performance of a gravity-driven membrane bioreactor (GDMBR) during treatment of synthetic sewage. Results show that in situ coagulation significantly increased permeability (more than two-fold); however, no stabilization of permeability occurred over the whole operation, when non-coagulated and pre-coagulated reactors were compared. The high permeability observed was attributed to the accumulated aluminium floc in the reactor, which prevented formation of fluorescent microbial metabolites (aromatic and tryptophan proteins, as well as fulvic acids), and further avoided membrane pore blocking. In addition, the surface porosity of the fouling layer was improved (from 11.2% to 32.4% for non-coagulated and in situ coagulated reactors). The unstable permeability was possibly associated with lower biological processes within the fouling layer. These might include lower adenosine triphosphate (ATP) content and lower fluorescent metabolites from the extracellular polymeric substances (EPS) caused by the accumulated Al (compared with the control). On the other hand, pre-coagulation improved the level of stable permeability compared with the control (80 versus 40 L/m 2 h bar), mainly because pre-coagulation decreased the EPS content and also maintained high ATP content of the fouling layer. In addition, both coagulation processes reduced the total filtration resistance, mainly the hydraulically reversible resistance and cake layer resistance, which could lower the cleaning frequency. Overall, coagulation could greatly increase the removal efficiency and improve the GDMBR permeability, which would make the process suitable for decentralized wastewater treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ferrate(VI) as a greener oxidant: Electrochemical generation and treatment of phenol.
Sun, Xuhui; Zhang, Qi; Liang, He; Ying, Li; Xiangxu, Meng; Sharma, Virender K
2016-12-05
Ferrate(VI) (Fe(VI)O4(2-), Fe(VI)) is a greener oxidant in the treatment of drinking water and wastewater. The electrochemical synthesis of Fe(VI) may be considered environmentally friendly because it involves one-step process to convert Fe(0) to Fe(VI) without using harmful chemicals. Electrolysis was performed by using a sponge iron as an anode in NaOH solution at different ionic strengths. The cyclic voltammetric (CV) curves showed that the sponge iron had higher electrical activity than the grey cast iron. The optimum current density was 0.054mAcm(-2) in 10M NaOH solution, which is much lower than the electrolyte concentrations used in other electrode materials. A comparison of current efficiency and energy consumption was conducted and is briefly discussed. The generated ferrate solution was applied to degrade phenol in water at two levels (2mgL(-1) and 5mgL(-1)). The maximum removal efficiency was ∼70% and the optimum pH for phenol treatment was 9.0. Experiments on phenol removal using conventional coagulants (ferric chloride (FeCl3) and polyaluminium chloride (PAC)) were performed independently to demonstrate that removal of phenol by Fe(VI) occurred mainly by oxidative transformation. A combination of Fe(VI) and coagulant may be advantageous in enhancing removal efficiency, adjusting pH, and facilitating flocculation. Copyright © 2015 Elsevier B.V. All rights reserved.
Use of combined coagulation-adsorption process as pretreatment of landfill leachate
2013-01-01
Landfill leachate is an important pollution factor resulting from municipal landfill sites. Physical and chemical processes are the better option for pretreatment or full treatment of landfill leachate. This article presents a combination of pre-treatment method (coagulation and adsorption) for leachate collected from municipal solid waste open dumping site. Physico chemical characteristics of stabilized and fresh leachate were examined. Coagulation process was examined by using alum and ferric chloride. A low cost adsorbent, fly ash was used for adsorption studies. Coagulation studies were carried out for fresh and stabilized leachate. Adsorption studies have been conducted for alum pre-treated stabilized leachate. Effect of coagulant dose, adsorbent dose, pH and contact time were carried out. The effective optimum coagulant dosages were 0.6 g/L and 0.7 g/L for alum and ferric chloride respectively for stabilized leachate and incase of fresh leachate 0.8 g/L and 0.6 g/L for alum and ferric chloride respectively. For the alum pretreated stabilized leachate, the maximum COD removal is 28% using fly ash adsorbent with equilibrium time of 210 min and optimum dose of 6 g/L. Overall COD removal efficiency of 82% was obtained by coagulation using alum and adsorption using fly ash for stabilized leachate. The results obtained showed that combined coagulation and adsorption process can be used effectively for stabilized leachate treatment. PMID:23517661
Proteins at the Biomaterial Electrolyte Interface
NASA Astrophysics Data System (ADS)
Tengvall, Pentti
2005-03-01
Proteins adsorb rapidly onto solid and polymeric surfaces because the association process is in the vast majority of cases energetically favourable, i.e. exothermic. The most common exceptions to this rule are hydrophilic interfaces with low net charge and high mobility, e.g. immobilized PEGs. Current research in the research area tries to understand and control unwanted and wanted adsorption by studying the adsorption kinetics, protein surface binding specificity, protein exchange at interfaces, and surface protein repulsion mechanisms. In blood plasma model systems humoral cascade reactions such as surface mediated coagulation and immune complement raise considerable interest due to the immediate association to blood compatibility, and in tissue applications the binding between surfaces and membrane receptors in cells and tissues. Thus, the understanding of interfacial events at the protein level is of large importance in applications such as blood and tissue contacting biomaterials, in vitro medical and biological diagnostics, food industry and in marine anti-fouling technology. Well described consequences of adsorption are a lowered system energy, increased system entropy, irreversible binding, conformational changes, specific surface/protein interactions, and in biomedical materials applications surface opsonization followed by cell-surface interactions and a host tissue response. This lecture will deal with some mechanisms known to be of importance for the adsorption processes, such as the influence of surface chemistry and surface energy, the composition of the protein solution, the Vroman effect, and residence time. Examples will be shown from ellipsometric experiments using different model surfaces in single/few protein solutions, and specific attention be given to blood serum and plasma experiments on coagulation and immune complement at interfaces.
Zhao, Zilong; Dong, Wenyi; Wang, Hongjie; Chen, Guanhan; Tang, Junyi; Wu, Yang
2018-05-15
This research explored the application of electro-Fenton (E-Fenton) technique for the simultaneous decomplexation in blended Cu(II)/Ni(II)-EDTA systems by using iron sacrificing electrodes. Standard discharge (0.3 mg L -1 for Cu and 0.1 mg L -1 for Ni in China) could be achieved after 30 min reaction under the optimum conditions (i.e. initial solution pH of 2.0, H 2 O 2 dosage of 6 mL L -1 h -1 , current density of 20 mA/cm 2 , inter-electrode distance of 2 cm, and sulfate electrolyte concentration of 2000 mg L -1 ). The distinct differences in apparent kinetic rate constants (k app ) and intermediate removal efficiencies corresponding to mere and blended systems indicated the mutual promotion effect toward the decomplexation between Cu(II) and Ni(II). Massive accumulation of Fe(Ⅲ) favored the further removal of Cu(II) and Ni(II) by metal ion substitution. Species distribution results demonstrated that the decomplexation of metal-EDTA in E-Fenton process was mainly contributed to the combination of various reactions, including Fenton reaction together with the anodic oxidation, electro-coagulation (E-coagulation) and electrodeposition. Unlike hypophosphite and citrate, the presence of chlorine ion displayed favorable effects on the removal efficiencies of Cu(II) and Ni(II) at low dosage, but facilitated the ammonia nitrogen (NH 4 + -N) removal only at high dosage. Copyright © 2018 Elsevier B.V. All rights reserved.
Treatment of waste water by coagulation and flocculation using biomaterials
NASA Astrophysics Data System (ADS)
Muruganandam, L.; Saravana Kumar, M. P.; Jena, Amarjit; Gulla, Sudiv; Godhwani, Bhagesh
2017-11-01
The present study deals with the determination of physical and chemical parameters in the treatment process of waste water by flocculation and coagulation processes using natural coagulants and assessing their feasibility for water treatment by comparing the performance with each other and with a synthetic coagulant. Initial studies were done on the synthetic waste water to determine the optimal pH and dosage, the activity of natural coagulant, followed by the real effluent from tannery waste. The raw tannery effluent was bluish-black in colour, mildly basic in nature, with high COD 4000mg/l and turbidity in the range 700NTU, was diluted and dosed with organic coagulants, AloeVera, MoringaOleifera and Cactus (O.ficus-indica). The study observed that coagulant Moringa Oleifera of 15 mg/L dose at 6 pH gave the best reduction efficiencies for major physicochemical parameters followed by Aloe Vera and Cactus under identical conditions. The study reveals that the untreated tannery effluents can be treated with environmental confirmative naturally occurring coagulants.
Coagulation chemistries for silica removal from cooling tower water.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom
2010-02-01
The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants deliveredmore » promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.« less
Kumar, Abhijeet; Nidheesh, P V; Suresh Kumar, M
2018-08-01
Treatment of composite wastewater generating from the industrial estates is a great challenge. The present study examines the applicability of aerated electrocoagulation and modified peroxi-coagulation processes for removing color and COD from composite wastewater. Iron plates were used as anodes and cathodes in both electrochemical processes and experiments were carried out in a working volume of 2 L. Aeration enhanced the efficiency of electrocoagulation process significantly. More than 50% of COD and 60% of color were removed after 1 h of electrocoagulation process operated at pH 3 and applied voltage of 1 V. Efficiency of the modified peroxi-coagulation process was significantly higher than that of aerated electrocoagulation. COD and color removal efficiencies of the modified peroxi-coagulation process were found as 77.7% and 97%, respectively after 1 h of electrolysis operated at 1 V, solution pH 3 and 50 mM hydrogen peroxide addition. This improved efficiency of modified peroxi-coagulation compared to aerated electrocoagulation is mainly due to the attack of in-situ generated hydroxyl radicals. Copyright © 2018 Elsevier Ltd. All rights reserved.
Metcalfe, David; Rockey, Chris; Jefferson, Bruce; Judd, Simon; Jarvis, Peter
2015-12-15
This investigation aimed to compare the disinfection by-product formation potentials (DBPFPs) of three UK surface waters (1 upland reservoir and 2 lowland rivers) with differing characteristics treated by (a) a full scale conventional process and (b) pilot scale processes using a novel suspended ion exchange (SIX) process and inline coagulation (ILCA) followed by ceramic membrane filtration (CMF). Liquid chromatography-organic carbon detection analysis highlighted clear differences between the organic fractions removed by coagulation and suspended ion exchange. Pretreatments which combined SIX and coagulation resulted in significant reductions in dissolved organic carbon (DOC), UV absorbance (UVA), trihalomethane and haloacetic acid formation potential (THMFP, HAAFP), in comparison with the SIX or coagulation process alone. Further experiments showed that in addition to greater overall DOC removal, the processes also reduced the concentration of brominated DBPs and selectively removed organic compounds with high DBPFP. The SIX/ILCA/CMF process resulted in additional removals of DOC, UVA, THMFP, HAAFP and brominated DBPs of 50, 62, 62, 62% and 47% respectively compared with conventional treatment. Copyright © 2015. Published by Elsevier Ltd.
Cardiovascular and systemic effects of gastric dilatation and volvulus in dogs.
Sharp, Claire R; Rozanski, Elizabeth A
2014-09-01
Gastric dilatation and volvulus (GDV) is a common emergency condition in large and giant breed dogs that is associated with high morbidity and mortality. Dogs with GDV classically fulfill the criteria for the systemic inflammatory response syndrome (SIRS) and can go on to develop multiple organ dysfunction syndrome (MODS). Previously reported organ dysfunctions in dogs with GDV include cardiovascular, respiratory, gastrointestinal, coagulation and renal dysfunction. Cardiovascular manifestations of GDV include shock, cardiac arrhythmias and myocardial dysfunction. Respiratory dysfunction is also multifactorial, with contributory factors including decreased respiratory excursion due to gastric dilatation, decreased pulmonary perfusion and aspiration pneumonia. Gastrointestinal dysfunction includes gastric necrosis and post-operative gastrointestinal upset such as regurgitation, vomiting, and ileus. Coagulation dysfunction is another common feature of MODS in dogs with GDV. Disseminated intravascular coagulation can occur, putting them at risk of complications associated with thrombosis in the early hypercoagulable state and hemorrhage in the subsequent hypocoagulable state. Acute kidney injury, acid-base and electrolyte disturbances are also reported in dogs with GDV. Understanding the potential for systemic effects of GDV allows the clinician to monitor patients astutely and detect such complications early, facilitating early intervention to maximize the chance of successful management. Copyright © 2014 Elsevier Inc. All rights reserved.
Alexander, Jonathan T; Hai, Faisal I; Al-Aboud, Turki M
2012-11-30
Trace organic contaminants have become an increasing cause of concern for governments and water authorities as they attempt to respond to the potential challenges posed by climate change by implementing sustainable water cycle management practices. The augmentation of potable water supplies through indirect potable water reuse is one such method currently being employed. Given the uncertainty surrounding the potential human health impacts of prolonged ingestion of trace organic contaminants, it is vital that effective and sustainable treatment methods are utilized. The purpose of this article is to provide a comprehensive literature review of the performance of the chemical coagulation process in removing trace organic contaminants from water. This study evaluated the removal data collated from recent research relating to various trace organic contaminants during the coagulation process. It was observed that there is limited research data relating to the removal of trace organic contaminants using coagulation. The findings of this study suggest that there is a gap in the current research investigating the potential of new types of coagulants and exploring coagulation-based hybrid processes to remove trace organic contaminants from water. The data analysed in this study regarding removal efficiency suggests that, even for the significantly hydrophobic compounds, hydrophobicity is not the sole factor governing removal of trace organic contaminants by coagulation. This has important implications in that the usual practice of screening coagulants based on turbidity (suspended solid) removal proves inadequate in the case of trace organic contaminant removal. Copyright © 2012 Elsevier Ltd. All rights reserved.
Polyferric sulphate: preparation, characterisation and application in coagulation experiments.
Zouboulis, A I; Moussas, P A; Vasilakou, F
2008-07-15
The process of coagulation is a core environmental protection technology, which is mainly used in the water or wastewater treatment facilities. Research is now focused on the development of inorganic pre-polymerised coagulants. A characteristic example is PFS (polyferric sulphate), a relatively new pre-polymerised inorganic coagulant with high cationic charge. In this paper, the role of major parameters, including temperature, types of chemical reagents, ratio r=[OH]/[Fe], rate of base addition in the preparation stages of PFS were investigated. Furthermore, the prepared PFS was characterised based on typical properties, such as the percentage of the polymerised iron present in the compound, z-potential, pH, etc. Moreover, dynamics of coagulation process were examined by means of the Photometric Dispersion Analyzer (PDA). Finally, the coagulation efficiency of PFS in treating kaolin suspension and biologically pre-treated wastewater was evaluated in comparison with the respective conventional coagulant agent. The results indicate that certain parameters, such as the r value, the rate of base addition and the duration and temperature of the polymerisation stage, significantly affected the properties of the PFS. Additionally, the prepared PFS polymerised coagulants exhibit a significantly better coagulation performance than the respective non-polymerised one, i.e. ferric sulphate.
Micro- and mesoscopic process interactions in protein coagulation
NASA Astrophysics Data System (ADS)
San Biagio, P. L.; Martorana, V.; Emanuele, A.; Vaiana, S. M.; Manno, M.; Bulone, D.; Palma-Vittorelli, M. B.; Palma, M. U.
2000-04-01
It has recently been recognized that pathological protein coagulation is responsible for lethal pathologies as diverse as amyloidosis, Alzheimer and TSE. Understanding the coagulation mechanisms is therefore stirring great interest. In previous studies we have shown that on profoundly different systems coagulation is the result of a strong interaction between two processes on different length scales (mesoscopic and microscopic). Here we report experiments on bovine serum albumin (BSA) showing that the overall mechanism is the result of at least 3 distinct and strongly intertwined processes, on both length scales: molecular conformational changes, solution demixing and intermolecular crosslinking. This mechanism involves the statistical mechanics of protein-solvent interaction, its relation to the protein's landscape of configurational free energy and to the solution's thermodynamic stability, and its relation to the topological problem of crosslink-percolation, responsible for coagulation.
Perdigón-Melón, J A; Carbajo, J B; Petre, A L; Rosal, R; García-Calvo, E
2010-09-15
A coupled coagulation-Fenton process was applied for the treatment of cosmetic industry effluents. In a first step, FeSO(4) was used as coagulant and the non-precipitated Fe(2+) remaining in dissolution was used as catalyst in the further Fenton process. In the coagulation process a huge decrease in total organic carbon (TOC) was achieved, but the high concentration of phenol derivatives was not diminished. The decrease in TOC in the coagulation step significantly reduces the amount of H(2)O(2) required in the Fenton process for phenol depletion. The coupled process, using a H(2)O(2) dose of only 2 g l(-1), reduced TOC and total phenol to values lower than 40 and 0.10 mg l(-1), respectively. The short reaction period (less than 15 min) in TOC and phenol degradation bodes well for improving treatment in a continuous regime. The combination of both processes significantly reduced the ecotoxicity of raw effluent and markedly increased its biodegradability, thus allowing easier treatment by the conventional biological units in conventional sewage treatment plants (STPs). Copyright 2010 Elsevier B.V. All rights reserved.
Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J
2010-08-01
The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.
Review of Coagulation Technology for Removal of Arsenic: Case of Chile
2006-01-01
Coagulation technology has been used since 1970 in northern Chile for removing arsenic from drinking-water. This experience suggests that coagulation is an effective technology for the removal of arsenic. It is currently possible to reduce arsenic from 400 μg/L to 10 μg/L at a rate of 500 L/sec, assuming pH, oxidizing and coagulation agents are strictly controlled. The Chilean experience with the removal of arsenic demonstrates that the water matrix dictates the selection of the arsenic-removal process. This paper presents a summary of the process, concepts, and operational considerations for the use of coagulation technology for removal of arsenic in Chile. PMID:17366767
Cosmetic wastewater treatment by coagulation and advanced oxidation processes.
Naumczyk, Jeremi; Bogacki, Jan; Marcinowski, Piotr; Kowalik, Paweł
2014-01-01
In this study, the treatment process of three cosmetic wastewater types has been investigated. Coagulation allowed to achieve chemical oxygen demand (COD) removal of 74.6%, 37.7% and 74.0% for samples A (Al2(SO4)3), B (Brentafloc F3) and C (PAX 16), respectively. The Fenton process proved to be effective as well - COD removal was equal to 75.1%, 44.7% and 68.1%, respectively. Coagulation with FeCl3 and the subsequent photo-Fenton process resulted in the best values of final COD removal equal to 92.4%, 62.8% and 90.2%. In case of the Fenton process, after coagulation these values were equal to 74.9%, 50.1% and 84.8%, while in case of the H2O2/UV process, the obtained COD removal was 83.8%, 36.2% and 80.9%. High value of COD removal in the Fenton process carried out for A and C wastewater samples was caused by a significant contribution of the final neutralization/coagulation. Very small effect of the oxidation reaction in the Fenton process in case of sample A resulting from the presence of antioxidants, 'OH radical scavengers' in the wastewater.
Characteristics of BPA removal from water by PACl-Al13 in coagulation process.
Xiaoying, Ma; Guangming, Zeng; Chang, Zhang; Zisong, Wang; Jian, Yu; Jianbing, Li; Guohe, Huang; Hongliang, Liu
2009-09-15
This paper discussed the coagulation characteristics of BPA with polyaluminum chloride (PACl-Al(13)) as coagulant, examined the impact of coagulation pH, PACl-Al(13) dosage, TOC (total organic carbon) and turbidity on BPA removal, and analyzed the possible dominant mechanisms in water coagulation process. Formation and performance of flocs during coagulation processes were monitored using photometric dispersion analyzer (PDA). When the concentration of humic acid matters and turbidity was low in the solution, the experimental results showed that the removal of BPA experienced increase and subsequently decrease with the PACl-Al(13) dosage increasing. The optimal PACl-Al(13) dosage was found at BPA/PACl-Al(13)=1:2.6(M/M) under our experiment conditions. Results show that the maximum BPA removal efficiency occurred at pH 9.0 due to the adsorption by Al(13) aggregates onto BPA rather than charge neutralization mechanism by polynuclear aluminous salts in the solution. The humic acid matters and kaolin in the solution have significant effect on BPA removal with PACl-Al(13) in the coagulation. The BPA removal will be weakened at high humic matters. The removal rate of BPA increased and subsequently decreased with the turbidity increasing.
Wang, Miaomiao; Meng, Yingjie; Ma, Defang; Wang, Yan; Li, Fengli; Xu, Xing; Xia, Chufan; Gao, Baoyu
2017-05-01
This study investigated the N-nitrosodimethylamine (NDMA) formation potential of various dissolved organic matter (DOM) fractions in biologically treated municipal wastewater by UF fractionation, XAD-8 resin adsorption isolation, and excitation and emission matrix (EEM) fluorescence spectroscopy. Removal of various NDMA precursor fractions was also analyzed to evaluate the efficiency of traditional water treatment processes (coagulation, adsorption, and coagulation-adsorption). Results showed that NDMA were mainly formed by low molecular weight (MW) fractions (<30 kDa) and hydrophilic fractions (HiS) in biologically treated municipal wastewater. Integrated coagulation-adsorption treatments showed the highest reduction capacity for NDMA formation potential (57%), followed by isolated adsorption treatment (50%) and isolated coagulation treatment (28%). The powdered activated carbon (PAC) adsorption process could reduce the high MW precursors (>30 kDa) by 48%, which was higher than other treatments. In contrast, the highest uptake (66%) of low MW precursors (<30 kDa) was achieved by the coagulation-adsorption process. All treatments preferentially removed the hydrophobic acids (HoA) fraction compared to other fractions. Coagulation could remove more fulvic acid-like substances and adsorption could remove more microbial by-products and aromatic proteins.
[Influencing factors and mechanism of arsenic removal during the aluminum coagulation process].
Chen, Gui-Xia; Hu, Cheng-Zhi; Zhu, Ling-Feng; Tong, Hua-Qing
2013-04-01
Aluminum coagulants are widely used in arsenic (As) removal during the drinking water treatment process. Aluminium chloride (AlCl3) and polyaluminium chloride (PACl) which contains high content of Al13 were used as coagulants. The effects of aluminum species, pH, humic acid (HA) and coexisting anions on arsenic removal were investigated. Results showed that AlCl3 and PACl were almost ineffective in As(II) removal while the As(V) removal efficiency reached almost 100%. pH was an important influencing factor on the arsenic removal efficiency, because pH influenced the distribution of aluminum species during the coagulation process. The efficiency of arsenic removal by aluminum coagulants was positively correlated with the content of Al13 species. HA and some coexisting anions showed negative impact on arsenic removal because of the competitive adsorption. The negative influence of HA was more pronounced at low coagulant dosages. PO4(3-) and F(-) showed marked influence during arsenic removal, but there was no obvious influence when SiO3(2-), CO3(2-) and SO4(2-) coexisted. The present study would be helpful to direct arsenic removal by enhanced coagulation during the drinking water treatment.
Torres, Luis G; Belloc, Claudia; Vaca, Mabel; Iturbe, Rosario; Bandala, Erick R
2009-11-01
Wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. The wastewater contained petroleum hydrocarbons, a surfactant, i.e., sodium dodecyl sulfate (SDS) as well as salts, brownish organic matter and other constituents that were lixiviated from the soil during the washing process. The main goal of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and also be disposed at the end of the process properly. A second objective was to study the relationship among the coagulant and flocculant doses and the pH at which the CF process is developed, for systems where methylene blue active substances (MBAS) as well as oil and greases were present. The results for the selection of the right coagulant and flocculant type and dose, the optimum pH value for the CF process and the interactions among the three parameters are detailed along this work. The best coagulant and flocculant were FeCl(3) and Tecnifloc 998 at doses of 4,000 and 1 mg/L, correspondingly at pH of 5. These conditions gave color, turbidity, chemical oxygen demand (COD) and conductivity removals of 99.8, 99.6, 97.1 and 35%, respectively. It was concluded that it is feasible to treat the wastewaters generated in the contaminated soil washing process through CF process, and therefore, wastewaters could be recycled to the washing process or disposed to drainage.
Zhang, Li-Zhu; Chen, Xiao-Dong; Ma, Jun; Yu, Min; Li, Xin
2011-10-01
Phenol was selected as a model compound. Factors, such as Ca2+, tannic acid, dose of kaolinite, dose of manganese dioxide formed in situ and pH, were invested on phenol removal in the process of enhanced coagulation by manganese dioxide formed in situ. Results showed that the addition of Ca2+ is beneficial for phenol removal. In the range of Ca2+ varied from 0 to 1.0 mmol x L(-1), the efficiency of phenol removal was enhanced more than 10%. Tannic acid can enhance phenol removal significantly when they are coexisted in water. As tannic acid was added to 10 mg x L(-1), phenol removal can be increased about 30% and 50% in the process of coagulation by AlCl3 and enhanced coagulation by manganese dioxide formed in situ, respectively. The dose of coagulant can be reduced in the process of enhanced coagulation with the addition of manganese dioxide formed in situ. The point of 1 mg x L(-1) manganese dioxide formed in situ linked with 30 mg x L(-1) AlCl3 can have the same phenol removal efficiency as the addition of 50 mg x L(-1) AlCl3. In the range of pH varied from 5 to 9, phenol can be removed with the high efficiency in the process of enhanced coagulation by manganese dioxide formed in situ. While under the strong acid condition and strong basic condition, phenol has lower removal efficiency.
Reciprocal coupling of coagulation and innate immunity via neutrophil serine proteases.
Massberg, Steffen; Grahl, Lenka; von Bruehl, Marie-Luise; Manukyan, Davit; Pfeiler, Susanne; Goosmann, Christian; Brinkmann, Volker; Lorenz, Michael; Bidzhekov, Kiril; Khandagale, Avinash B; Konrad, Ildiko; Kennerknecht, Elisabeth; Reges, Katja; Holdenrieder, Stefan; Braun, Siegmund; Reinhardt, Christoph; Spannagl, Michael; Preissner, Klaus T; Engelmann, Bernd
2010-08-01
Blood neutrophils provide the first line of defense against pathogens but have also been implicated in thrombotic processes. This dual function of neutrophils could reflect an evolutionarily conserved association between blood coagulation and antimicrobial defense, although the molecular determinants and in vivo significance of this association remain unclear. Here we show that major microbicidal effectors of neutrophils, the serine proteases neutrophil elastase and cathepsin G, together with externalized nucleosomes, promote coagulation and intravascular thrombus growth in vivo. The serine proteases and extracellular nucleosomes enhance tissue factor- and factor XII-dependent coagulation in a process involving local proteolysis of the coagulation suppressor tissue factor pathway inhibitor. During systemic infection, activation of coagulation fosters compartmentalization of bacteria in liver microvessels and reduces bacterial invasion into tissue. In the absence of a pathogen challenge, neutrophil-derived serine proteases and nucleosomes can contribute to large-vessel thrombosis, the main trigger of myocardial infarction and stroke. The ability of coagulation to suppress pathogen dissemination indicates that microvessel thrombosis represents a physiological tool of host defense.
NASA Astrophysics Data System (ADS)
Sun, Zhaonan; Liu, Zheng; Hu, Xiaomin
2017-05-01
The method of treating pharmaceutical wastewater by electro-coagulation with Al/Fe periodically reversing (ECPR) was proposed based on traditional electrochemical method. The principle of ECPR was generalized. Mechanism of ECPR to treat berberine pharmaceutical wastewater was investigated. Treatability and mechanism studies were conducted under laboratory conditions. For berberine wastewater (800 mg/L), decolourization efficiency and COD removal efficiency were highest to 98% and 95% respectively when voltage was 8V, reaction time was 60 min, alternating period was 10 S electrolyte concentration was 0.015 mol/L, stirring speed was 750 rpm, pH value was 3-10 and distance between two plates was 0.6 cm. For removal berberine, flocculation, floatation and oxidation provided 73%, 8% and 18% removal efficiency, which can be inferred by analysing UV-visible absorption spectrum, acidification experiment, EDTA shielding experiment, structure-activity relationship, oxidation and floatation. Meanwhile decolourization and COD removal conformed to apparent pseudo-first order and zero-order kinetics for 200mg/L and 400-1000 mg/L berberine wastewater respectively.
Electromagnetic induction sensor for dynamic testing of coagulation process.
Wang, Zhe; Yu, Yuanhua; Yu, Zhanjiang; Chen, Qimeng
2018-03-01
With the increasing demand for coagulation POCT for patients in the surgery department or the ICU, rapid coagulation testing techniques and methods have drawn widespread attention from scholars and businessmen. This paper proposes the use of electromagnetic induction sensor probe for detection of dynamic process causing changes in the blood viscosity and density before and after coagulation based on the damped vibration principle, in order to evaluate the coagulation status. Utilizing the dynamic principle, the differential equation of vibration system comprising elastic support and electromagnetic induction device is established through sensor dynamic modeling. The structural parameters of elastic support are optimized, and the circular sheet spring is designed. Furthermore, harmonic response analysis and vibration fatigue coupling analysis are performed on the elastic support of the sensor by considering the natural frequency of the system, and the electromagnetic induction sensor testing device is set up. Using the device and coagulation reagent, the standard curve for coagulation POCT is plotted, and the blood sample application in clinical patients is established, which are methodologically compared with the imported POCT coagulation analyzer. The results show that the sensor designed in this paper has a first-order natural frequency of 11.368 Hz, which can withstand 5.295 × 10 2 million times of compressions and rebounds. Its correlation with the results of SONOCLOT analyzer reaches 0.996, and the reproducibility 0.002. The electromagnetic induction coagulation testing sensor designed has good elasticity and anti-fatigue, which can meet the accuracy requirement of clinical detection. This study provides the core technology for developing the electromagnetic induction POCT instrument for dynamic testing of coagulation process.
Ozkan, O; Mihçiokur, H; Azgin, S T; Ozdemir, O
2010-01-01
Wastewater from a medical-waste sterilisation plant (MWSP) contains unique pollutants and requires on-site treatment to prevent contamination of the municipal sewage system and receiving water bodies. Therefore, to meet the prescribed discharge standards and comply with the legal regulations, pre-treatment must be applied to MWSP wastewater. In this study, the capabilities of coagulation-flocculation processes were investigated for MWSP wastewater treatment. Processes using ferric chloride, ferrous sulfate and aluminium sulfate as coagulants were characterised. During the coagulation experiments, seven different coagulant dosages and four different pH values were evaluated to determine the optimum coagulant dosage and pH value. The highest removal efficiency of chemical oxygen demand (COD) was obtained using 300 mg/L of ferric chloride at pH 10. A COD removal of about 60% as well as considerable reductions in the amounts of suspended solids, nitrogen and phosphorus were realised.
Emergent self-similarity of cluster coagulation
NASA Astrophysics Data System (ADS)
Pushkin, Dmtiri O.
A wide variety of nonequilibrium processes, such as coagulation of colloidal particles, aggregation of bacteria into colonies, coalescence of rain drops, bond formation between polymerization sites, and formation of planetesimals, fall under the rubric of cluster coagulation. We predict emergence of self-similar behavior in such systems when they are 'forced' by an external source of the smallest particles. The corresponding self-similar coagulation spectra prove to be power laws. Starting from the classical Smoluchowski coagulation equation, we identify the conditions required for emergence of self-similarity and show that the power-law exponent value for a particular coagulation mechanism depends on the homogeneity index of the corresponding coagulation kernel only. Next, we consider the current wave of mergers of large American banks as an 'unorthodox' application of coagulation theory. We predict that the bank size distribution has propensity to become a power law, and verify our prediction in a statistical study of the available economical data. We conclude this chapter by discussing economically significant phenomenon of capital condensation and predicting emergence of power-law distributions in other economical and social data. Finally, we turn to apparent semblance between cluster coagulation and turbulence and conclude that it is not accidental: both of these processes are instances of nonlinear cascades. This class of processes also includes river network formation models, certain force-chain models in granular mechanics, fragmentation due to collisional cascades, percolation, and growing random networks. We characterize a particular cascade by three indicies and show that the resulting power-law spectrum exponent depends on the indicies values only. The ensuing algebraic formula is remarkable for its simplicity.
Reuteler, Annina; Axiak-Flammer, Shannon; Howard, Judith; Adamik, Katja-Nicole
2017-01-01
To evaluate the effects of a 6% hydroxyethyl starch (130/0.42) solution in either a buffered, electrolyte-balanced (HES-BAL), or a saline (HES-SAL) carrier solution on canine platelet function and whole blood coagulation. Prospective, randomized study. University teaching hospital. Thirty-seven client-owned dogs undergoing general anesthesia for arthroscopy or imaging studies. Dogs received a 15 mL/kg intravenous bolus of HES-SAL (n = 13), HES-BAL (n = 14), or a modified Ringer's solution (n = 10) over 30-40 minutes. Coagulation was analyzed using a Platelet Function Analyzer-100 (closure time [Ct PFA ]), and whole blood thromboelastometry (ROTEM) with extrinsically (ex-tem and fib-tem) and intrinsically (in-tem) activated assays, which assessed clotting time (CT), clot formation time (CFT), maximal clot firmness (MCF), and lysis index (LI). Coagulation samples were assayed prior to fluid administration (T0), and 5 minutes (T1), and 3 hours (T2) following fluid bolus administration, respectively. Both HES solutions resulted in impaired platelet function as indicated by a significant prolongation of Ct PFA at T1 as compared to T0, but which resolved by T2. An IV bolus of Ringer's solution did not alter platelet function. In both HES groups, whole blood coagulation was significantly impaired at T1 as indicated by a significant increase in in-tem CFT, and a significant decrease in ex-tem, in-tem, and fib-tem MCF compared to T0. Furthermore, a significant increase in ex-tem CFT at T1 compared to T0 was found in the HES-SAL group. With the exception of in-tem MCF after HES-BAL, these effects were not present at T2. No significant differences were found in Ct PFA or any ROTEM variable at any time point between HES-SAL and HES-BAL. Administration of a single bolus of 15 mL/kg 6% HES 130/0.42 results in significant but short-lived impairment of canine platelet function and whole blood coagulation, regardless of carrier solution. © Veterinary Emergency and Critical Care Society 2016.
NASA Technical Reports Server (NTRS)
Chokshi, Arati; Tielens, Alexander G. G. M.; Hollenbach, David
1989-01-01
Coagulation is an important mechanism in the growth of interstellar and interplanetary dust particles. The microphysics of the coagulation process was theoretically analyzed as a function of the physical properties of the coagulating grains, i.e., their size, relative velocities, temperature, elastic properties, and the van der Waal interaction. Numerical calculations of collisions between linear chains provide the wave energy in individual particles and the spectrum of the mechanical vibrations set up in colliding particles. Sticking probabilities are then calculated using simple estimates for elastic deformation energies and for the attenuation of the wave energy due to absorption and scattering processes.
Optimum coagulant forecasting by modeling jar test experiments using ANNs
NASA Astrophysics Data System (ADS)
Haghiri, Sadaf; Daghighi, Amin; Moharramzadeh, Sina
2018-01-01
Currently, the proper utilization of water treatment plants and optimizing their use is of particular importance. Coagulation and flocculation in water treatment are the common ways through which the use of coagulants leads to instability of particles and the formation of larger and heavier particles, resulting in improvement of sedimentation and filtration processes. Determination of the optimum dose of such a coagulant is of particular significance. A high dose, in addition to adding costs, can cause the sediment to remain in the filtrate, a dangerous condition according to the standards, while a sub-adequate dose of coagulants can result in the reducing the required quality and acceptable performance of the coagulation process. Although jar tests are used for testing coagulants, such experiments face many constraints with respect to evaluating the results produced by sudden changes in input water because of their significant costs, long time requirements, and complex relationships among the many factors (turbidity, temperature, pH, alkalinity, etc.) that can influence the efficiency of coagulant and test results. Modeling can be used to overcome these limitations; in this research study, an artificial neural network (ANN) multi-layer perceptron (MLP) with one hidden layer has been used for modeling the jar test to determine the dosage level of used coagulant in water treatment processes. The data contained in this research have been obtained from the drinking water treatment plant located in Ardabil province in Iran. To evaluate the performance of the model, the mean squared error (MSE) and correlation coefficient (R2) parameters have been used. The obtained values are within an acceptable range that demonstrates the high accuracy of the models with respect to the estimation of water-quality characteristics and the optimal dosages of coagulants; so using these models will allow operators to not only reduce costs and time taken to perform experimental jar tests but also to predict a proper dosage for coagulant amounts and to project the quality of the output water under real conditions.
Li, Shuocong; Liu, Hong; Gao, Rui; Abdurahman, Abliz; Dai, Juan; Zeng, Feng
2018-06-01
Microplastics are an emerging contaminants of concern in aquatic environments. The aggregation behaviors of microplastics governing their fate and ecological risks in aquatic environments is in need of evaluation. In this study, the aggregation behavior of polystyrene microspheres (micro-PS) in aquatic environments was systematically investigated over a range of monovalent and divalent electrolytes with and without natural organic matter (i.e., Suwannee River humic acid (HA)), at pH 6.0, respectively. The zeta potentials and hydrodynamic diameters of micro-PS were measured and the subsequent aggregation kinetics and attachment efficiencies (α) were calculated. The aggregation kinetics of micro-PS exhibited reaction- and diffusion-limited regimes in the presence of monovalent or divalent electrolytes with distinct critical coagulation concentration (CCC) values, followed the Derjaguin-Landau-Verwey-Overbeek (DLVO) theory. The CCC values of micro-PS were14.9, 13.7, 14.8, 2.95 and 3.20 mM for NaCl, NaNO 3 , KNO 3 , CaCl 2 and BaCl 2 , respectively. As expected, divalent electrolytes (i.e., CaCl 2 and BaCl 2 ) had stronger influence on the aggregation behaviors of micro-PS as compared to monovalent electrolytes (i.e., NaCl, NaNO 3 and KNO 3 ). HA enhanced micro-PS stability and shifted the CCC values to higher electrolyte concentrations for all types of electrolytes. The CCC values of micro-PS were lower than reported carbonaceous nanoparticles CCC values. The CCC[Ca 2+ ]/CCC [Na + ] ratios in the absence and presence of HA at pH 6.0 were proportional to Z -2.34 and Z -2.30 , respectively. These ratios were in accordance with the theoretical Schulze-Hardy rule, which considers that the CCC is proportional to z -6 -z -2 . These results indicate that the stability of micro-PS in the natural aquatic environment and the possibility of significant aqueous transport of micro-PS. Copyright © 2018 Elsevier Ltd. All rights reserved.
Shin, Hyun-Jung; Na, Hyo-Seok; Jeon, Young-Tae; Park, Hee-Pyoung; Nam, Sun-Woo; Hwang, Jung-Won
2017-01-01
Abstract Although endoscopic transurethral resection of the prostate (TURP) is a well-established procedure as a treatment for benign prostatic hyperplasia, its complications remain a concern. Among these, coagulopathy may be caused by the absorption of irrigating fluid. This study aimed to evaluate such phenomenon using a rotational thromboelastometry (ROTEM). A total of 20 patients undergoing TURP participated in this study. A mixture of 2.7% sorbitol–0.54% mannitol solution and 1% ethanol was used as an irrigating fluid, and fluid absorption was measured via the ethanol concentration in expired breath. The effects on coagulation were assessed by pre- and postoperative laboratory blood tests, including hemoglobin, hematocrit, platelet count, international normalized ratio of prothrombin time (PT-INR), activated partial thromboplastin time, electrolyte, and ROTEM. INTEM-clotting time (INTEM-CT) was significantly lengthened by 14% (P = 0.001). INTEM-α-angle was significantly decreased by 3% (P = 0.011). EXTEM-clot formation time was significantly prolonged by 18% (P = 0.008), and EXTEM-maximum clot firmness (EXTEM-MCF) was significantly decreased by 4% (P = 0.010). FIBTEM-MCF was also significantly decreased by 13% (P = 0.015). Moreover, hemoglobin (P < 0.001), hematocrit (P < 0.001), platelet counts (P < 0.001), potassium (P = 0.024), and ionized calcium (P = 0.004) were significantly decreased, while PT-INR (P = 0.001) was significantly increased after surgery. The amount of irrigating fluid absorbed was significantly associated with the weight of resected prostatic tissue (P = 0.001) and change of INTEM-CT (P < 0.001). As shown by the ROTEM analysis, the irrigating fluid absorbed during TURP impaired the blood coagulation cascade by creating a disruption in the coagulation factor activity or by lowering the coagulation factor concentration via dilution. PMID:28079789
Shin, Hyun-Jung; Na, Hyo-Seok; Jeon, Young-Tae; Park, Hee-Pyoung; Nam, Sun-Woo; Hwang, Jung-Won
2017-01-01
Although endoscopic transurethral resection of the prostate (TURP) is a well-established procedure as a treatment for benign prostatic hyperplasia, its complications remain a concern. Among these, coagulopathy may be caused by the absorption of irrigating fluid. This study aimed to evaluate such phenomenon using a rotational thromboelastometry (ROTEM).A total of 20 patients undergoing TURP participated in this study. A mixture of 2.7% sorbitol-0.54% mannitol solution and 1% ethanol was used as an irrigating fluid, and fluid absorption was measured via the ethanol concentration in expired breath. The effects on coagulation were assessed by pre- and postoperative laboratory blood tests, including hemoglobin, hematocrit, platelet count, international normalized ratio of prothrombin time (PT-INR), activated partial thromboplastin time, electrolyte, and ROTEM.INTEM-clotting time (INTEM-CT) was significantly lengthened by 14% (P = 0.001). INTEM-α-angle was significantly decreased by 3% (P = 0.011). EXTEM-clot formation time was significantly prolonged by 18% (P = 0.008), and EXTEM-maximum clot firmness (EXTEM-MCF) was significantly decreased by 4% (P = 0.010). FIBTEM-MCF was also significantly decreased by 13% (P = 0.015). Moreover, hemoglobin (P < 0.001), hematocrit (P < 0.001), platelet counts (P < 0.001), potassium (P = 0.024), and ionized calcium (P = 0.004) were significantly decreased, while PT-INR (P = 0.001) was significantly increased after surgery. The amount of irrigating fluid absorbed was significantly associated with the weight of resected prostatic tissue (P = 0.001) and change of INTEM-CT (P < 0.001).As shown by the ROTEM analysis, the irrigating fluid absorbed during TURP impaired the blood coagulation cascade by creating a disruption in the coagulation factor activity or by lowering the coagulation factor concentration via dilution.
Microalgae removal with Moringa oleifera.
Barrado-Moreno, M M; Beltran-Heredia, J; Martín-Gallardo, J
2016-02-01
Moringa oleifera seed extract was tested for algae (Chlorella, Microcystis, Oocystis and Scenedesmus) removal by Jar-test technique. This coagulant can be used in drinking water treatment. Jar-test has been carried out in order to evaluate the efficiency of this natural coagulant agent inside real surface water matrix. The influence of variables has been studied in this process, including operating parameters such as coagulant dosage, initial algae concentration, pH, agitation time and water matrix. Removal capacity is verified for water with high contamination of algae while the process is not affected by the pH and water matrix. Coagulation process may be modelling through Langmuir and Freundlich adsorption hypothesis, so acceptable r2 coefficients are obtained. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Takeshita, Kenji; Ogata, Takeshi
By the Fukushima nuclear disaster, large amounts of water and sea water polluted mainly with radioactive Cs were generated and the environment around the nuclear site was contaminated by the fallout from the nuclear site. The coagulation settling process using ferric ferrocyanide and an inorganic coagulant and the adsorption process using ferric ferrocyanide granulated by silica binder were applied to the treatment of polluted water. In the coagulation settling process, Cs was removed completely from polluted water and sea water (DF∼104). In the adsorption process, the recovery of trace Cs (10 ppb) in sea water, which was not suitable for the use of zeolite, was attained successfully. Finally, the recovery of Cs from sewage sludge was tested by a combined process with the hydrothermal process using subcritical water and the coagulation settling process using ferric ferrocyanide. 96% of radioactive Cs was recovered successfully from sewage sludge with the radioactivity of 10,000 Bq/kg.
Influential factors of formation kinetics of flocs produced by water treatment coagulants.
Wu, Chunde; Wang, Lin; Hu, Bing; Ye, Jian
2013-05-01
The growth rate and size of floc formation is of great importance in water treatment especially in coagulation process. The floc formation kinetics and the coagulation efficiency of synthetic water were investigated by using an on-line continuous optical photometric dispersion analyze and the analysis of water quality. Experimental conditions such as alum dosage, pH value for coagulation, stirring intensity and initial turbidity were extensively examined. The photometric dispersion analyze results showed that coagulation of kaolin suspensions with two coagulants (alum and polyaluminium chloride) could be taken as a two-phase process: slow and rapid growth periods. Operating conditions with higher coagulant doses, appropriate pH and average shear rate might be particularly advantageous. The rate of overall floc growth was mainly determined by a combination of hydraulic and water quality conditions such as pH and turbidity. The measurement of zeta potential indicates that polyaluminium chloride exhibited higher charge-neutralizing ability than alum and achieved lower turbidities than alum for equivalent Al dosages. Under the same operating conditions, the alum showed a higher grow rate, but with smaller floc size.
Colloids removal from water resources using natural coagulant: Acacia auriculiformis
NASA Astrophysics Data System (ADS)
Abdullah, M.; Roslan, A.; Kamarulzaman, M. F. H.; Erat, M. M.
2017-09-01
All waters, especially surface waters contain dissolved, suspended particles and/or inorganic matter, as well as several biological organisms, such as bacteria, algae or viruses. This material must be removed because it can affect the water quality that can cause turbidity and colour. The objective of this study is to develop water treatment process from Seri Alam (Johor, Malaysia) lake water resources by using natural coagulant Acacia auriculiformis pods through a jar test experiment. Jar test is designed to show the effectiveness of the water treatment. This process is a laboratory procedure that will simulate coagulation/flocculation with several parameters selected namely contact time, coagulant dosage and agitation speed. The most optimum percentage of colloids removal for each parameter is determined at 0.2 g, 90 min and 80 rpm. FESEM (Field-emission Scanning Electron Microscope) observed the small structures of final floc particles for optimum parameter in this study to show that the colloids coagulated the coagulant. All result showed that the Acacia auriculiformis pods can be a very efficient coagulant in removing colloids from water.
NASA Astrophysics Data System (ADS)
Laptev, A. G.; Basharov, M. M.; Farakhova, A. I.
2013-09-01
The process through which small droplets contained in emulsions are physically coagulated on the surface of random packing elements is considered. The theory of turbulent migration of a finely dispersed phase is used for determining the coagulation efficiency. Expressions for calculating coagulation efficiency and turbulent transfer rate are obtained by applying models of a turbulent boundary layer. An example of calculating the enlargement of water droplets in hydrocarbon medium represented by a wide fraction of light hydrocarbons (also known as natural gas liquid) is given. The process flowchart of a system for removing petroleum products from effluent waters discharged from the Kazan TETs-1 cogeneration station is considered. Replacement of the mechanical filter by a thin-layer settler with a coagulator is proposed.
Studies on the treatment of surface water using rajma seeds
NASA Astrophysics Data System (ADS)
Merlin, S. Babitha; Abirami, M.; Kumar, R. Suresh
2018-03-01
Indiscriminate disposal of wastewater with suspended solids have led to higher amount of pollution to the natural water bodies. Turbidity removal becomes an essential part in the water treatment when surface water is used for drinking purpose, this can be achieved by means of coagulation process. Coagulation process is the dosing of a coagulant in water, resulting in the destabilization of negatively charged particles. Commercial coagulants which were widely used can synthesize by-products in turn may pollute the environment and deteriorate the ecosystem at a slow rate. So, now-a-days natural coagulants are used as a potential substitute because it's biodegradable, ecofriendly and non-toxic. In this study, the turbid surface water samples were treated using powdered seeds of Rajma (natural coagulant) followed by variations in dosage, settling time and pH were also studied. From the results obtained, it was found that the Rajma seeds powder achieved 48.80% efficiency for 0.5 g/l of optimum dose at pH 6 for 20 min settling time respectively.
Nishizaki, Naoto; Maiguma, Atsuko; Obinata, Kaoru; Okazaki, Tadaharu; Shimizu, Toshiaki
2016-01-01
Brain hypothermic therapy (BHT) is becoming a frequently used standard of care for perinatal asphyxia. Although cardiovascular side effects, coagulation disorders, renal impairment, electrolyte abnormalities, impaired liver function, opportunistic infections, and skin lesions are well-known adverse effects of BHT in newborns, little information is available on the clinical features of intestinal perforation-related BHT. We herein report a case of therapeutic brain cooling for perinatal asphyxia complicated by localized intestinal perforation. In practice, the neonatologist should be aware that intestinal perforation in an infant with perinatal asphyxia is possible, particularly following BHT.
[Application of improved regional citrate anticoagulation in continuous hemofiltration in children].
Bai, K; Liu, C J; Fu, Y Q; Xu, F
2017-05-04
Objective: To investigate the application of regional citrate anticoagulation with calcium hemofiltration basic solution in continuous hemofiltration in children. Method: The clinical data of 18 patients with citrate anticoagulation in continuous hemofiltration in children, excluding the hepatic failure and septic shock cases, were analyzed retrospectively, from September 2015 to August 2016 in Intensive Care Unit of the Children's Hospital of Chongqing Medical University.The commercial calcium hemofiltration basic solution was used as displacement liquid . The blood gas analysis, electrolyte, four coagulation tests during the treatment and the corresponding relations of quantity of blood flow(QB), quantity of citrate flow(QCi), quantity of sodium bicarbonate flow(QSB), quantity of calcium flow(QCa), quantity of filtered solution flow (Qf) were monitored. Meanwhile, the blood gas analysis, electrolyte, four coagulation tests, useful life of filter, bleeding and clotting events internal and external before, during and after the treatments were monitored, too. And the common complications of citrate anticoagulation, such as hypocalcaemia, metabolic alkalosis, citrate accumulation and hypernatremia were observed. Result: Continuous hemofiltration was applied in 18 patients for 734.5 hours, and the average useful life of filter was (25±11)h.There was no obvious clotting event. There were 168 groups of datum of the blood gas analysis, electrolyte, four coagulation tests during the treatment and the relationships of QB, QCi, QSB, QCa, Qf had been collected. The relationships of the initial parameter settings of QB, QCi, QSB, QCa and Qf were concluded as QCi=1.8×QB, QCa=0.12×QB, QSB=0.01×Qf . There were 150 times(89.3%)of extracorporeal ionized calcium(iCa(E)(2+)) and 162 times(96.4%) of intracorporal ionized calcium(iCa(I)(2+)) reached the anticoagulation target. Although all the comparisons of Na(+) ((136.2±4.1) vs .(138.2±2.4) vs .(138.5±3.9)mmol/L), iCa(2+) ((1.07±0.11) vs .(1.21±0.12) vs .(1.17±0.09)mmol/L), HCO(3)(-) ((22±4) vs .(28±5) vs . (26±4)mmol/L) among before, during and after treatment had significant difference( F =6.414, 18.950, 19.151; P =0.002, 0.000, 0.000). Each mean parameter was within the nearly normal range, except that the HCO(3)(-) increased slightly. High HCO(3)(-) was the most common complications, which happened 87 times (51.8%) during the treatment and 11 cases(37.9%) after the treatment. There was none with refractory hypocalcemia and total ionized calcium(TCa(2+) )/iCa(2+) above 2.5, which hints the accumulation of citrate. Conclusion: The commercialized displacement liquid containing calcium can be used in RCA-CHF in children safely and simply.
Application of low-mixing energy input for the coagulation process.
Vadasarukkai, Yamuna S; Gagnon, Graham A
2015-11-01
Rapid-mixing tanks with mechanical mixers are a common design used in treatment plants. Yet, the role of such rapid-mixing systems on the effectiveness of the coagulation performance is unclear. This study looked at optimizing the direct energy used in the coagulation process for removal of natural dissolved organic matter (DOM). The role of coagulation mixing intensity (G-value) on total organic carbon (TOC) and turbidity removal was examined for the water types with high organic content, with a specific ultraviolet absorbance (SUVA) of at least 2-2.5 units of m(-1) of absorbance per mg/L. A standard jar test using ferric sulfate coagulant was performed to optimize the chemical condition in coagulation for removal of dissolved organics as well as particles. The jar test analysis at an acidic pH (4.5 ± 0.3) required an iron dose <0.3 mM to arrive at an optimal coagulant concentration and resulted in above 75% of TOC removal. The influence of coagulation mixing on TOC and turbidity removal was evaluated at G varying from 0 to 1500 s(-1) at the optimized coagulant dose and pH conditions for enhanced coagulation. In this study, a combined effective removal of TOC and turbidity was achieved at a low-mixing intensity range of 110 s(-1) < G < 450 s(-1). Coagulation operated at G greater than 450 s(-1) showed negligible improvement in TOC removal. Minimizing energy consumption in enhanced coagulation is feasible at the proposed mixing intensity range (i.e., 110 s(-1) < G < 450 s(-1)), without sacrificing the effectiveness of DOM removal by coagulation. These findings represent an opportunity for energy savings for the water industry without sacrificing quality. Copyright © 2015 Elsevier Ltd. All rights reserved.
Effect of adsorbent addition on floc formation and clarification.
Younker, Jessica M; Walsh, Margaret E
2016-07-01
Adding adsorbent into the coagulation process is an emerging treatment solution for targeting hard-to-remove dissolved organic compounds from both drinking water and industrial wastewater. The impact of adding powdered activated carbon (PAC) or organoclay (OC) adsorbents with ferric chloride (FeCl3) coagulant was investigated in terms of potential changes to the coagulated flocs formed with respect to size, structure, and breakage and regrowth properties. The ability of dissolved air flotation (DAF) and sedimentation (SED) clarification processes to remove hybrid adsorbent-coagulant flocs was also evaluated through clarified water quality analysis of samples collected in bench-scale jar test experiments. The jar tests were conducted using both a synthetic fresh water and oily wastewater test water spiked with dissolved aromatic compounds phenol and naphthalene. Results of the study demonstrated that addition of adsorbent reduced the median coagulated floc size by up to 50% but did not affect floc strength or regrowth potential after application of high shear. Experimental results in fresh water demonstrated that sedimentation was more effective than DAF for clarification of both FeCl3-PAC and FeCl3-OC floc aggregates. However, experimental tests performed on the synthetic oily wastewater showed that coagulant-adsorbent floc aggregates were effectively removed with both DAF and sedimentation treatment, with lower residual turbidity achieved in clarified water samples than with coagulation treatment alone. Addition of OC or PAC into the coagulation process resulted in removals of over half, or nearly all of the dissolved aromatics, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.
Amor, Carlos; De Torres-Socías, Estefanía; Peres, José A; Maldonado, Manuel I; Oller, Isabel; Malato, Sixto; Lucas, Marco S
2015-04-09
This work reports the treatment of a mature landfill leachate through the application of chemical-based treatment processes in order to achieve the discharge legal limits into natural water courses. Firstly, the effect of coagulation/flocculation with different chemicals was studied, evaluating the role of different initial pH and chemicals concentration. Afterwards, the efficiency of two different advanced oxidation processes for leachate remediation was assessed. Fenton and solar photo-Fenton processes were applied alone and in combination with a coagulation/flocculation pre-treatment. This physicochemical conditioning step, with 2 g L(-1) of FeCl3 · 6H2O at pH 5, allowed removing 63% of COD, 80% of turbidity and 74% of total polyphenols. Combining the coagulation/flocculation pre-treatment with Fenton reagent, it was possible to reach 89% of COD removal in 96 h. Moreover, coagulation/flocculation combined with solar photo-Fenton revealed higher DOC (75%) reductions than single solar photo-Fenton (54%). In the combined treatment (coagulation/flocculation and solar photo-Fenton), it was reached a DOC reduction of 50% after the chemical oxidation, with 110 kJ L(-1) of accumulated UV energy and a H2O2 consumption of 116 mM. Toxicity and biodegradability assays were performed to evaluate possible variations along the oxidation processes. After the combined treatment, the leachate under study presented non-toxicity but biodegradability increased. Copyright © 2014 Elsevier B.V. All rights reserved.
Rhabdomyolysis. The role of diagnostic and prognostic factors
Keltz, Eran; Khan, Fahmi Yousef; Mann, Gideon
2013-01-01
Summary Rhabdomyolysis, literally meaning the breakdown of muscle tissue, is a common syndrome with many causes, acquired ones such as exertion, trauma, infections, temperature extremes, drugs, toxins, electrolyte and endocrine abnormalities, and congenital ones such as myopathies and connective tissue disorders. All results in a common pathophysiologic pathway which ends with the dispersing of muscle tissue content into the circulation. Rhabdomyolysis has characteristic clinical, laboratory and radiologic features, but does require a high index of suspicion so that the diagnosis would not be missed. The sensitivity and specificity of the various characteristics, as well as clinical guidelines, are discussed in this paper. The syndrome may present with several complications, e.g. arrhythmias, electrolyte abnormalities, acute renal injury, acidosis, volume depletion, compartment syndrome and disseminated intravascular coagulation. The prognosis is highly variable and depends on the underlying etiologies and complications, but is in general considered as good. The milestone of treatment is vigorous fluid resuscitation. Treatment options, in practice and in research, are discussed in the following pages. PMID:24596694
Coagulation of Dust Particles in Argon Plasma of RF Discharge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mankelevich, Yu. A.; Olevanov, M. A.; Pal, A. F.
2008-09-07
The experiments on coagulation of poly-disperse particles with various size distributions injected into the argon plasma of the magnetron radio-frequency discharge are discussed. The experiments were carried out under the conditions similar to those using dusty plasma for technology applications. Within the created theory the threshold behavior of the coagulation process was explained for the first time, the estimation of the critical particle size for onset of a fast coagulation was made, and the analytical calculation of the coagulation rate of dust particles was performed. The proposed coagulation mechanism makes it possible to describe the typical features of coagulation processesmore » observed in experiments and to explain the effects of attraction and coalescence of highly negatively charged microns size particles.« less
Wang, Yili; Guo, Jinlong; Tang, Hongxiao
2002-01-01
Factors of pretreatment coagulation/flocculation units were studied using raw water of low temperature and low turbidity. Aluminum sulfate (AS) and selected polyaluminium chlorides (PACls) were all effective in the DAF process when used under favorable conditions of coagulant addition, coagulation, flocculation and flotation units. Compared with the AS coagulant, PACls, at lower dosage, could give the same effective performance even with shorter coagulation/flocculation time or lower recycle ratio during the treatment of cold water. This is attributed to the higher-charged polymeric Al species, and the lower hydrophilic and more compact flocculated flocs of PACl coagulant. Based on results of pilot experiments, the goal of FRD system can be achieved by combining a DAF heterocoagulation reactor with PACl coagulant (F), an efficient flocculation reactor (R), as well as an economical auto-dosing system (D).
Effects of low temperature on coagulation of kaolinite suspensions.
Xiao, Feng; Ma, Jun; Yi, Peng; Huang, Ju-Chang Howard
2008-06-01
In this study, coagulation of kaolinite suspensions at low temperatures is compared with that at an ambient temperature of 22 degrees C, and the process is examined with regard to the coagulation rate (CR) and chemical aspects of coagulation. Experiments using a photometric dispersion analyzer (PDA) show that coagulation of kaolinite suspensions can be taken as a two-phase process. Low temperature greatly reduces the CR of the first phase but not that of the second one. On the other hand, results show that low temperature did not serve to impede the hydrolysis of aluminum [Al(III)] within 1 min of alum addition. The measurements of electrophoretic mobility (EM) indicate that destabilization of kaolinite particles by hydrolyzed Al species was not hindered by low temperature within 1 min of alum addition. Slow coagulation at low temperature is due to the lowered CR but not the altered chemistry aspect of Al(III). Furthermore, the change in settled turbidity after 20-min flocculation as a function of coagulant dosage was more severe in the cold because of the low CR. Elongating floc-growth time, as observed, was able to counterbalance the retarded CR at low temperature and improve turbidity removal efficiency.
Coagulation pretreatment for ultrafiltration of deinking effluents containing flexographic inks
Bruno Chabot; Gopal A. Krishnagopalan; Said Abubakr
1999-01-01
This study was carried out to determine the potential of coagulation pretreatment with organic or inorganic coagulants to improve ultrafiltration performance during processing of wash deinking effluents containing flexographic inks. Wash filtrate effluents generated from mixtures of old flexographic and offset newspapers and old magazines were pretreated with a...
Malik, Sameena N; Ghosh, Prakash C; Vaidya, Atul N; Waindeskar, Vishal; Das, Sera; Mudliar, Sandeep N
2017-09-01
In this study, the comparative performance of coagulation, ozone, coagulation + ozone + coagulation and potassium ferrate processes to remove chemical oxygen demand (COD), color, and toxicity from a highly polluted textile wastewater were evaluated. Experimental results showed that ferrate alone had no effect on COD, color and toxicity removal. Whereas, in combination with FeSO 4 , it has shown the highest removal efficiency of 96.5%, 83% and 75% for respective parameters at the optimal dose of 40 mgL -1 + 3 ml FeSO 4 (1 M) in comparison with other processes. A seed germination test using seeds of Spinach (Spinacia oleracea) also indicated that ferrate was more effective in removing toxicity from contaminated textile wastewater. Potassium ferrate also produces less sludge with maximum contaminant removal, thereby making the process more economically feasible. Fourier transform infrared spectroscopy (FTIR) analysis also shows the cleavage of the chromophore group and degradation of textile wastewater during chemical and oxidation treatment processes.
Zhang, Liyong; Zhang, Penghui; Wang, Meng; Yang, Kai; Liu, Junliang
2016-09-01
The processes and effects of coagulation-ultrafiltration (C-UF) and coagulation sedimentation-ultrafiltration (CS-UF) process used in the treatment of Dalangdian Reservoir water were compared. The experiment data indicated that 99% of turbidity removal and basically 100% of microorganism and algae removal were achieved in both C-UF and CS-UF process. The organic removal effect of CS-UF? process was slightly better than C-UF process. However, the organic removal effect under different processes was not obvious due to limitation of ultrafiltration membrane aperture. Polyaluminium chloride was taken as a coagulant in water plant. The aluminum ion removal result revealed that coagulant dosage was effectively saved by using membrane technology during megathermal high algae laden period. Within the range of certain reagent concentration and soaking time, air-water backwashing of every filtration cycle of membrane was conducted to effectively reduce membrane pollution. Besides, maintenance cleaning was conducted every 60 min. whether or not restorative cleaning was conducted depends on the pollution extent. After cleaning, recovery of membrane filtration effect was obvious.
Pretreatment of palm oil mill effluent (POME) using Moringa oleifera seeds as natural coagulant.
Bhatia, Subhash; Othman, Zalina; Ahmad, Abdul Latif
2007-06-25
Moringa oleifera seeds, an environmental friendly and natural coagulant are reported for the pretreatment of palm oil mill effluent (POME). In coagulation-flocculation process, the M. oleifera seeds after oil extraction (MOAE) are an effective coagulant with the removal of 95% suspended solids and 52.2% reduction in the chemical oxygen demand (COD). The combination of MOAE with flocculant (NALCO 7751), the suspended solids removal increased to 99.3% and COD reduction was 52.5%. The coagulation-flocculation process at the temperature of 30 degrees C resulted in better suspended solids removal and COD reduction compared to the temperature of 40, 55 and 70 degrees C. The MOAE combined with flocculant (NALCO 7751) reduced the sludge volume index (SVI) to 210mL/g with higher recovery of dry mass of sludge (87.25%) and water (50.3%).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takeshita, K.; Takahashi, H.; Jinbo, Y.
2013-07-01
In the Fukushima Daiichi NPP Accident, large amounts of volatile radioactive nuclides, such as {sup 131}I, {sup 134}Cs and {sup 137}Cs, were released to the atmosphere and huge areas surrounding the nuclear site were contaminated by the radioactive fallout. In this study, a combined process with a hydrothermal process and a coagulation settling process was proposed for the separation of radioactive Cs from contaminated soil and sewage sludge. The coagulation settling operation uses Prussian Blue (Ferric ferrocyanide) and an inorganic coagulant. The recovery of Cs from sewage sludge sampled at Fukushima city (100.000 Bq/kg) and soil at a nearby villagemore » (55.000 Bq/kg), was tested. About 96% of Cs in the sewage sludge was removed successfully by combining simple hydrothermal decomposition and coagulation settling. However, Cs in the soil was not removed sufficiently by the combined process (Cs removal is only 56%). The hydrothermal decomposition with blasting was carried out. The Cs removal from the soil was increased to 85%. When these operations were repeated twice, the Cs recovery was over 90%. The combined process with hydrothermal blasting and coagulation settling is applicable to the removal of Cs from highly contaminated soil.« less
Gang, Dianchen; Clevenger, Thomas E; Banerji, Shankha K
2005-01-01
The impacts of alum coagulation on the distribution of disinfection by-products (DBPs), trihalomethanes (THMs), and haloacetic acids (HAAs) were evaluated under controlled chlorination conditions using four surface waters. Among the nine HAAs found in waters, dihaloacetic acids (X2AAs) have been found to be the dominant species in all of the raw and alum treated waters. Alum coagulation tends to remove more monohaloacetic acids (XAAs) and trihaloacetic acids (X3AAs) precursors than that of dihaloacetic acids (X2AAs). Alum coagulation treated water had a lower HAA9/TTHM ratio compared with that of the raw water. The increase of THM bromine incorporation factors (BIFalpha) value of alum treated water was statistically significant in comparison with the raw water. On average, BIFalpha increased by 54% after the alum coagulation process in these four different waters. This indicated that THM speciations shifted in favor of the more brominated compounds. However, alum coagulation treatment process had less effect on HAA bromi ne incorporation factors (BIFbeta)than it did on BIFalpha. Bromine incorporation factor (BIF) values decreased with time in the THM and HAA formation processes, especially within the first 10 h of the reaction time. This suggested that brominated THMs or HAAs formed faster than the chlorinated species in the initial period.
Removal of arsenic and iron removal from drinking water using coagulation and biological treatment.
Pramanik, Biplob Kumar; Pramanik, Sagor Kumar; Suja, Fatihah
2016-02-01
Effects of biological activated carbon (BAC), biological aerated filter (BAF), alum coagulation and Moringa oleifera coagulation were investigated to remove iron and arsenic contaminants from drinking water. At an initial dose of 5 mg/L, the removal efficiency for arsenic and iron was 63% and 58% respectively using alum, and 47% and 41% respectively using Moringa oleifera. The removal of both contaminants increased with the increase in coagulant dose and decrease in pH. Biological processes were more effective in removing these contaminants than coagulation. Compared to BAF, BAC gave greater removal of both arsenic and iron, removing 85% and 74%, respectively. Longer contact time for both processes could reduce the greater concentration of arsenic and iron contaminants. The addition of coagulation (at 5 mg/L dosage) and a biological process (with 15 or 60 min contact time) could significantly increase removal efficiency, and the maximum removal was observed for the combination of alum and BAC treatment (60 min contact time), with 100% and 98.56% for arsenic and iron respectively. The reduction efficiency of arsenic and iron reduced with the increase in the concentration of dissolved organics in the feedwater due to the adsorption competition between organic molecules and heavy metals.
Sun, Cuizhen; Qiu, Jinwei; Zhang, Zhibin; Marhaba, Taha F; Zhang, Yanhao
2016-10-01
In this paper, flocculating performance and mechanisms of a new composite coagulant, poly-ferric aluminum chloride-polydimethyl diallylammonium chloride (PFAC-PD) with different OH - /(Fe 3+ + Al 3+ ) molar ratios, were investigated for humic acid (HA)-kaolin synthetic wastewater treatment. The impact of OH - /(Fe 3+ + Al 3+ ) molar ratios on the removal efficiencies of turbidity and dissolved organic carbon, specific UV absorbance, coagulation mechanisms and dynamics was explored during the coagulation process using composite coagulants. The coagulation experimental results revealed that the composite coagulants with lower OH - /(Fe 3+ + Al 3+ ) molar ratio exhibited better coagulation efficiency. When OH - /(Fe 3+ + Al 3+ ) molar ratio of the composite coagulant was 1.5, adsorption-bridging played a dominant role in coagulating HA-kaolin synthetic wastewater. The floc growth rate and floc size, increased with increasing OH - /(Fe 3+ + Al 3+ ) molar ratio and the highest peak height of the size distribution was obtained by PFAC-PD with OH - /(Fe 3+ + Al 3+ ) = 1.5. Also, the composite coagulants with higher OH - /(Fe 3+ + Al 3+ ) molar ratio formed more compact flocs, as reflected by the higher fractal dimension value. The flocs coagulated by PFAC-PD with basicity value of 1.0 gave strong strength and good recoverability.
Saxena, Shivendu; Rajoriya, Sunil; Saharan, Virendra Kumar; George, Suja
2018-06-01
In the present study, coagulation followed by cavitation was studied as a pretreatment tool for tannery waste effluent (TWE) with the aim of reducing its COD, TOC, TSS etc. and enhancing its biodegradability to make it suitable for anaerobic digestion. Initially, coagulation was applied to TWE using alum as a coagulant. The residual pH of treated effluent was found to be around pH of 4.5 where maximum COD and TSS reduction was achieved. In order to enhance the efficiency of pretreatment process, coagulated tannery waste effluent (CTWE) was further subjected to hydrodynamic cavitation (HC) and ultrasonication (US). In case of HC, effect of process parameters such as inlet pressure and dilution on the treatment of CTWE was initially investigated. Lower operating pressure (5 bar) was more favorable for the treatment of CTWE using HC in order to enhance the biodegradability index (BI) from 0.14 to 0.57 in 120 min. The CTWE samples when subjected to 50% dilution, HC pretreatment exhibited higher percentage and quantum reduction in TOC and COD. On the other hand, pretreatment of TWE using coagulation followed by US demonstrated that BI of effluent was enhanced from 0.10 to 0.41 in 150 min. Energy efficiency evaluation for all processes at their optimized conditions was done based on the actual amount of COD reduced per unit energy delivered to the system. Coagulation followed by HC for the pretreatment of TWE was found to be six times more energy efficient as compared to coagulation followed by US. Copyright © 2018 Elsevier B.V. All rights reserved.
Teter, David M.; Brady, Patrick V.; Krumhansl, James L.; Khandaker, Nadim R.
2006-11-21
An improved water decontamination process comprising contacting water containing anionic contaminants with an enhanced coagulant to form an enhanced floc, which more efficiently binds anionic species (e.g., arsenate, arsenite, chromate, fluoride, selenate, and borate, and combinations thereof) predominantly through the formation of surface complexes. The enhanced coagulant comprises a trivalent metal cation coagulant (e.g., ferric chloride or aluminum sulfate) mixed with a divalent metal cation modifier (e.g., copper sulfate or zinc sulfate).
Zayas Pérez, Teresa; Geissler, Gunther; Hernandez, Fernando
2007-01-01
The removal of the natural organic matter present in coffee processing wastewater through chemical coagulation-flocculation and advanced oxidation processes (AOP) had been studied. The effectiveness of the removal of natural organic matter using commercial flocculants and UV/H2O2, UV/O3 and UV/H2O2/O3 processes was determined under acidic conditions. For each of these processes, different operational conditions were explored to optimize the treatment efficiency of the coffee wastewater. Coffee wastewater is characterized by a high chemical oxygen demand (COD) and low total suspended solids. The outcomes of coffee wastewater treatment using coagulation-flocculation and photodegradation processes were assessed in terms of reduction of COD, color, and turbidity. It was found that a reduction in COD of 67% could be realized when the coffee wastewater was treated by chemical coagulation-flocculation with lime and coagulant T-1. When coffee wastewater was treated by coagulation-flocculation in combination with UV/H2O2, a COD reduction of 86% was achieved, although only after prolonged UV irradiation. Of the three advanced oxidation processes considered, UV/H2O2, UV/O3 and UV/H2O2/O3, we found that the treatment with UV/H2O2/O3 was the most effective, with an efficiency of color, turbidity and further COD removal of 87%, when applied to the flocculated coffee wastewater.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Zuwei; Zhao, Haibo, E-mail: klinsmannzhb@163.com; Zheng, Chuguang
2015-01-15
This paper proposes a comprehensive framework for accelerating population balance-Monte Carlo (PBMC) simulation of particle coagulation dynamics. By combining Markov jump model, weighted majorant kernel and GPU (graphics processing unit) parallel computing, a significant gain in computational efficiency is achieved. The Markov jump model constructs a coagulation-rule matrix of differentially-weighted simulation particles, so as to capture the time evolution of particle size distribution with low statistical noise over the full size range and as far as possible to reduce the number of time loopings. Here three coagulation rules are highlighted and it is found that constructing appropriate coagulation rule providesmore » a route to attain the compromise between accuracy and cost of PBMC methods. Further, in order to avoid double looping over all simulation particles when considering the two-particle events (typically, particle coagulation), the weighted majorant kernel is introduced to estimate the maximum coagulation rates being used for acceptance–rejection processes by single-looping over all particles, and meanwhile the mean time-step of coagulation event is estimated by summing the coagulation kernels of rejected and accepted particle pairs. The computational load of these fast differentially-weighted PBMC simulations (based on the Markov jump model) is reduced greatly to be proportional to the number of simulation particles in a zero-dimensional system (single cell). Finally, for a spatially inhomogeneous multi-dimensional (multi-cell) simulation, the proposed fast PBMC is performed in each cell, and multiple cells are parallel processed by multi-cores on a GPU that can implement the massively threaded data-parallel tasks to obtain remarkable speedup ratio (comparing with CPU computation, the speedup ratio of GPU parallel computing is as high as 200 in a case of 100 cells with 10 000 simulation particles per cell). These accelerating approaches of PBMC are demonstrated in a physically realistic Brownian coagulation case. The computational accuracy is validated with benchmark solution of discrete-sectional method. The simulation results show that the comprehensive approach can attain very favorable improvement in cost without sacrificing computational accuracy.« less
USDA-ARS?s Scientific Manuscript database
Interaction and coagulation of plant-derived dissolved organic matter (DOM) by metal cations are important biogeochemical processes of organic matter in lake systems. Thus, coagulation and fractionation of plant-derived DOM by di- and tri-valent Ca, Al, and Fe ions were investigated. Metal ion-induc...
Complement Activation Alters Platelet Function
2015-12-01
haemostatic and coagulation properties of platelets. 15. SUBJECT TERMS Platelets, Complement, Trauma, Tissue Damage 16. SECURITY CLASSIFICATION... coagulation , there is mounting evidence that they may also be important in the development and progression of inflammatory processes (Coppinger et al...receptor-ligand interactions and/or through exposure to cytokines including IL-6, other acute-phase reactants, and pro- coagulant factors such as thrombin
Impact of organic polyelectrolytes on coagulation of source-separated black water.
Kozminykh, Pavlo; Heistad, Arve; Ratnaweera, Harsha C; Todt, Daniel
2016-01-01
Household wastewater is originated from common people's activities and has a potential harmful impact on the environment if discharged directly without proper treatment. Toilet wastewater or black water (BW) contains urine, faeces, toilet paper and flushing water and it contains the majority of pollutants obtained from a single household. In this study, the focus was on BW treatment using chemical methods. The main goal of current research was to define the possibility and applicability of conventional coagulants and flocculants in direct chemical treatment of vacuum-collected BW to remove particles, organic matter and phosphorous. After the definition of dosing ranges, based on the equivalent doses in conventional municipal and industrial wastewater treatment data, aluminium and iron coagulants, organic polyelectrolytes (polymers with anionic, neutral and cationic charge with different molecular weights) and their various combinations were tested using the well-known jar-test laboratory method to study aggregation and solid-liquid separation processes in raw BW. The most important process parameter during the coagulation was pH level, dependent on the type and doses of metal salts. Some side processes were found to occur while using iron-based coagulants. Dosing of either single coagulants or single polymers did not give satisfactory results, while a combination of aluminium salts and cationic polymers showed high removal rates in total suspended solids, total chemical oxygen demand and ortho-phosphates, reaching 97.8%, 92% and 98.6%, respectively, with the optimal doses of chemicals. Cationic polymers with the lowest molecular weight and highest charge density were the most efficient in combination with aluminium coagulants.
NASA Astrophysics Data System (ADS)
Li, Na; Hu, Yi; Lu, Yong-Ze; Zeng, Raymond J.; Sheng, Guo-Ping
2016-05-01
To meet the high quality standard of receiving water, the coagulation process using polyferric chloride (PFC) was used to further improve the water quality of effluent from wastewater treatment plants. Uniform design (UD) coupled with response surface methodology (RSM) was adopted to assess the effects of the main influence factors: coagulant dosage, pH and basicity, on the removal of total organic carbon (TOC), NH4+-N and PO43--P. A desirability function approach was used to effectively optimize the coagulation process for the comprehensive removal of TOC, NH4+-N and PO43--P to upgrade the effluent quality in practical application. The optimized operating conditions were: dosage 28 mg/L, pH 8.5 and basicity 0.001. The corresponding removal efficiencies for TOC, NH4+-N and PO43--P were 77.2%, 94.6% and 20.8%, respectively. More importantly, the effluent quality could upgrade to surface water Class V of China through coagulation under optimal region. In addition, grey relational analysis (GRA) prioritized these three factors as: pH > basicity > dosage (for TOC), basicity > dosage > pH (for NH4+-N), pH > dosage > basicity (for PO43--P), which would help identify the most important factor to control the treatment efficiency of various effluent quality indexes by PFC coagulation.
Improving primary treatment of urban wastewater with lime-induced coagulation.
Marani, Dario; Ramadori, Roberto; Braguglia, Camilla Maria
2004-01-01
The enhancement of primary treatment efficiency through the coagulation process may yield several advantages, including lower aeration energy in the subsequent biological unit and higher recovery of biogas from sludge digestion. In this work sewage coagulation with lime was studied at pilot plant level, using degritted sewage from the city of Rome. The work aimed at optimising the operating conditions (coagulant dosage or treatment pH, and mixing conditions in the coagulation and flocculation tanks), in order to maximise the efficiency of suspended Chemical Oxygen Demand (COD) removal and to minimise sludge production. Lime dosage optimisation resulted in an optimal treatment pH of 9. Lime addition up to pH 9 may increase COD removal rate in the primary treatment from typical 30-35% of plain sedimentation up to 55-70%. Within the velocity gradients experimented in this work (314-795 s(-1) for the coagulation tank and 13-46 s(-1) for the flocculation tank), mixing conditions did not significantly affect the lime-enhanced process, which seems to be controlled by slow lime dissolution. Sludge produced in the lime-enhanced process settled and compacted easily, inducing an average 36% decrease in sludge volume with respect to plain settling. However excess sludge was produced, which was not accounted for by the amount of suspended solids removed. This is probably due to incomplete dissolution of lime, which may be partially incorporated in the sludge.
Wong, E A; Shin, G-A
2015-03-01
There has been a growing concern over human exposure to Mycobacterium avium subspecies hominissuis (MAH) through drinking water due to its ubiquitous presence in natural waters and remarkable resistance to both chemical and physical disinfectants in drinking water treatment processes. However, little is known about the effectiveness of physico-chemical water treatment processes to remove MAH. Therefore, we determined the removal of MAH by alum coagulation, flocculation and sedimentation processes in optimized drinking water treatment conditions using standard jar test equipment. Contrary to the prevailing hypothesis, the results of this study show that removal of MAH by coagulation, flocculation and sedimentation processes was only moderate (approx. 0.65 log10) under low turbidity treatment conditions and the removal of MAH was actually lower than that of Escherichia coli (reference bacterium) in all the waters tested. Overall, the results of this study suggested that coagulation, flocculation and sedimentation processes may not be a reliable treatment option for removing MAH, and more efforts to find an effective control measures against MAH should be made to reduce the risk of MAH infection from drinking water. Despite a growing concern over human exposure to Mycobacterium avium subspecies hominissuis (MAH) through drinking water and its remarkable resistance to water disinfectants, little is known about the effectiveness of physico-chemical water treatment processes to remove MAH. Contrary to the prevailing hypothesis, the results of this study suggest that coagulation, flocculation and sedimentation processes may not be a reliable treatment option for MAH removal. As these processes have been the last remaining conventional drinking water treatment processes that might be effective against MAH, more efforts should be urgently made to find an effective control measures against this important waterborne pathogen. © 2014 The Society for Applied Microbiology.
Wang, Ruican; Guo, Shuntang
2016-11-15
This study aims to clarify the roles played by endogenous small molecular components in soymilk coagulation process and the properties of gels. Soymilk samples with decreasing levels of small molecules were prepared by ultrafiltration, to reduce the amount of phytate and salts. CaSO4-induced coagulation process was analyzed using rheological methods. Results showed that removal of free small molecules decreased the activation energy of protein coagulation, resulting in accelerated reaction and increased gel strength. However, too fast a reaction led to the drop in storage modulus (G'). Microscopic observation suggested that accelerated coagulation generated a coarse and non-uniform gel network with large pores. This network could not hold much water, leading to serious syneresis. Endogenous small molecules in soymilk were vital in the fine gel structure. Coagulation rate could be controlled by adjusting the amount of small molecules to obtain tofu products with the optimal texture. Copyright © 2016 Elsevier Ltd. All rights reserved.
Dielectric coagulometry: a new approach to estimate venous thrombosis risk.
Hayashi, Yoshihito; Katsumoto, Yoichi; Omori, Shinji; Yasuda, Akio; Asami, Koji; Kaibara, Makoto; Uchimura, Isao
2010-12-01
We present dielectric coagulometry as a new technique to estimate the risk of venous thrombosis by measuring the permittivity change associated with the blood coagulation process. The method was first tested for a simple system of animal erythrocytes suspended in fibrinogen solution, where the coagulation rate was controlled by changing the amount of thrombin added to the suspension. Second, the method was applied to a more realistic system of human whole blood, and the inherent coagulation process was monitored without artificial acceleration by a coagulation initiator. The time dependence of the permittivity at a frequency around 1 MHz showed a distinct peak at a time that corresponds to the clotting time. Our theoretical modeling revealed that the evolution of heterogeneity and the sedimentation in the system cause the peak of the permittivity.
NASA Astrophysics Data System (ADS)
Shaylinda, M. Z. N.; Hamidi, A. A.; Mohd, N. A.; Ariffin, A.; Irvan, D.; Hazreek, Z. A. M.; Nizam, Z. M.
2018-04-01
In this research, the performance of polyferric chloride and tapioca flour as composite coagulants for partially stabilized leachate was investigated. Response surface methodology (RSM) was used to optimize the coagulation and flocculation process of partially stabilized leachate. Central composite design a standard design tool in RSM was applied to evaluate the interactions and effects of dose and pH. Dose 0.2 g/L Fe and pH 4.71 were the optimum value suggested by RSM. Experimental test based on the optimum condition, resulted in 95.9%, 94.6% and 50.4% of SS, color and COD removals, respectively. The percentage difference recorded between experimental and model responses was <5%. Therefore, it can be concluded that RSM was an appropriate optimization tool for coagulation and flocculation process.
Tan, Liqiang; Tan, Xiaoli; Mei, Huiyang; Ai, Yuejie; Sun, Lu; Zhao, Guixia; Hayat, Tasawar; Alsaedi, Ahmed; Chen, Changlun; Wang, Xiangke
2018-05-01
The coagulation behaviors of humic acid (HA) with Cs + (10-500 mM), Sr 2+ (0.8-10.0 mM) and Eu 3+ (0.01-1.0 mM) at different pH values (2.8, 7.1 and 10.0) were acquired through a dynamic light scattering (DLS) technique combined with spectroscopic analysis and molecular dynamic (MD) simulations. The coagulation rate and the average hydrodynamic diameter (
Probe measurements and numerical model predictions of evolving size distributions in premixed flames
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Filippo, A.; Sgro, L.A.; Lanzuolo, G.
2009-09-15
Particle size distributions (PSDs), measured with a dilution probe and a Differential Mobility Analyzer (DMA), and numerical predictions of these PSDs, based on a model that includes only coagulation or alternatively inception and coagulation, are compared to investigate particle growth processes and possible sampling artifacts in the post-flame region of a C/O = 0.65 premixed laminar ethylene-air flame. Inputs to the numerical model are the PSD measured early in the flame (the initial condition for the aerosol population) and the temperature profile measured along the flame's axial centerline. The measured PSDs are initially unimodal, with a modal mobility diameter ofmore » 2.2 nm, and become bimodal later in the post-flame region. The smaller mode is best predicted with a size-dependent coagulation model, which allows some fraction of the smallest particles to escape collisions without resulting in coalescence or coagulation through the size-dependent coagulation efficiency ({gamma}{sub SD}). Instead, when {gamma} = 1 and the coagulation rate is equal to the collision rate for all particles regardless of their size, the coagulation model significantly under predicts the number concentration of both modes and over predicts the size of the largest particles in the distribution compared to the measured size distributions at various heights above the burner. The coagulation ({gamma}{sub SD}) model alone is unable to reproduce well the larger particle mode (mode II). Combining persistent nucleation with size-dependent coagulation brings the predicted PSDs to within experimental error of the measurements, which seems to suggest that surface growth processes are relatively insignificant in these flames. Shifting measured PSDs a few mm closer to the burner surface, generally adopted to correct for probe perturbations, does not produce a better matching between the experimental and the numerical results. (author)« less
Zhou, Zhiwei; Yang, Yanling; Li, Xing
2015-11-01
Large amounts of drinking water treatment sludge (DWTS) are produced during the flocculation or flotation process. The recycling of DWTS is important for reducing and reclaiming the waste residues from drinking water treatment. To improve the coagulation step of the DWTS recycling process, power ultrasound was used as a pretreatment to disintegrate the DWTS and degrade or inactivate the constituents that are difficult to remove by coagulation. The effects of ultrasound pretreatment on the characteristics of DWTS, including the extent of disintegration, variation in DWTS floc characteristics, and DWTS dewaterability, were investigated. The capacity of the recycling process to remove particulates and organic matter from low-turbidity surface water compared to a control treatment process without DWTS was subsequently evaluated. The coagulation mechanism was further investigated by analyzing the formation, breakage, and re-growth of re-coagulated flocs. Our results indicated that under the low energy density applied (0.03-0.033 W/mL) for less than 15 min at a frequency of 160 kHz, the level of organic solubilization was less elevated, which was evidenced by the lower release of proteins and polysaccharides and lower fluorescence intensities of humic- and protein-like substances. The applied ultrasound conditions had an adverse effect on the dewaterability of the DWTS. Ultrasound pretreatment had no significant impact on the pH or surface charge of the DWTS flocs, whereas particle size decreased slightly and the specific surface area was moderately increased. The pollution removal capacity decreased somewhat for the recycled sonicated DWTS treatment, which was primarily ascribed to organic solubilization rather than variability in the floc characteristics of sonicated DWTS. The main coagulation mechanism was floc sweeping and physical adsorption. The breakage process of the flocs formed by the recycling process displayed distinct irreversibility, and the flocs were stronger and more resistant to breakage compared to those from the control treatment. Copyright © 2015 Elsevier B.V. All rights reserved.
Xue, Runmiao; Donovan, Ariel; Zhang, Haiting; Ma, Yinfa; Adams, Craig; Yang, John; Hua, Bin; Inniss, Enos; Eichholz, Todd; Shi, Honglan
2018-02-01
When adding sufficient chlorine to achieve breakpoint chlorination to source water containing high concentration of ammonia during drinking water treatment, high concentrations of disinfection by-products (DBPs) may form. If N-nitrosamine precursors are present, highly toxic N-nitrosamines, primarily N-nitrosodimethylamine (NDMA), may also form. Removing their precursors before disinfection should be a more effective way to minimize these DBPs formation. In this study, zeolites and activated carbon were examined for ammonia and N-nitrosamine precursor removal when incorporated into drinking water treatment processes. The test results indicate that Mordenite zeolite can remove ammonia and five of seven N-nitrosamine precursors efficiently by single step adsorption test. The practical applicability was evaluated by simulation of typical drinking water treatment processes using six-gang stirring system. The Mordenite zeolite was applied at the steps of lime softening, alum coagulation, and alum coagulation with powdered activated carbon (PAC) sorption. While the lime softening process resulted in poor zeolite performance, alum coagulation did not impact ammonia and N-nitrosamine precursor removal. During alum coagulation, more than 67% ammonia and 70%-100% N-nitrosamine precursors were removed by Mordenite zeolite (except 3-(dimethylaminomethyl)indole (DMAI) and 4-dimethylaminoantipyrine (DMAP)). PAC effectively removed DMAI and DMAP when added during alum coagulation. A combination of the zeolite and PAC selected efficiently removed ammonia and all tested seven N-nitrosamine precursors (dimethylamine (DMA), ethylmethylamine (EMA), diethylamine (DEA), dipropylamine (DPA), trimethylamine (TMA), DMAP, and DMAI) during the alum coagulation process. Copyright © 2017. Published by Elsevier B.V.
McMichael, Maureen
2012-05-01
Hemostasis is an essential protective mechanism that depends on a delicate balance of procoagulant and anticoagulant processes. The waterfall/cascade models of coagulation are useful for understanding several essential steps of coagulation in vitro. These have resulted in the creation of the plasma-based tests used commonly and the ability to identify deficiencies in the extrinsic, intrinsic, and common pathways of coagulation. The model was also essential in elucidating the role of several of the inhibitors of coagulation and is currently used to demonstrate coagulation as it occurs in plasma in a static environment that is devoid of endothelial interactions. The intrinsic pathway originally described by these models does not appear to be essential for in vivo hemostasis but may play a role in pathologic thrombosis. The waterfall/cascade models' lack of cellular elements sets the stage for the cell-based model of coagulation. The cell-based model of blood coagulation, which includes the varied, complicated network of factors necessary for appropriate in vivo coagulation to occur, was the next step in the evolution of our understanding of coagulation. Recently, researchers have focused on real-time, in vivo models of hemostasis and this research reveals unexpected phenomena. Copyright © 2012 Elsevier Inc. All rights reserved.
Ceramic electrolyte coating methods
Seabaugh, Matthew M.; Swartz, Scott L.; Dawson, William J.; McCormick, Buddy E.
2004-10-12
Processes for preparing aqueous suspensions of a nanoscale ceramic electrolyte material such as yttrium-stabilized zirconia. The invention also includes a process for preparing an aqueous coating slurry of a nanoscale ceramic electrolyte material. The invention further includes a process for depositing an aqueous spray coating slurry including a ceramic electrolyte material on pre-sintered, partially sintered, and unsintered ceramic substrates and products made by this process.
Qian, Feiyue; Sun, Xianbo; Liu, Yongdi; Xu, Hongyong
2013-01-01
GAC/O3 (ozonation in the presence of granular activated carbon) combined with enhanced coagulation was employed to process biotreated textile wastewater for possible reuse. The doses of ozone, GAC and coagulant were the variables studied for optimization. The effects of different treatment processes on effluent organic matter (EfOM) characteristics, including biodegradability, hydrophobic and hydrophilic nature, and apparent molecular weight (AMW) distribution were also investigated. Compared with ozonation, GAC/O3 not only presented a higher pre-oxidation efficiency, but also improved the treatability of hydrophobic and high molecular weight compounds by enhanced coagulation. After treatment by GAC/O3 pre-oxidation (0.6 mg O3 x mg(-1) COD and 20 g x L(-1) GAC) and enhanced coagulation (25 mg x L(-1) Al3+ at pH 5.5), the removal efficiencies of chemical oxygen demand (COD), dissolved organic carbon (DOC) and colour were higher than those for coagulation alone by 17.3%, 12.0% and 25.6%, respectively. Residual organic matter consisted mainly of hydrophobic acids and hydrophilic compounds of AMW < 1 kDa, which were colourless and of limited biological availability. The combination of GAC/O3 and enhanced coagulation was proved to be a simple and effective treatment strategy for removing EfOM from biotreated textile wastewater.
Geng, Jinhai; Liu, Gangjun; Chen, Zhongping
2013-01-01
Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d1/e) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening. PMID:23392340
Xu, Xiangqun; Geng, Jinhai; Liu, Gangjun; Chen, Zhongping
2013-08-01
Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d(1/e)) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening.
Genetics Home Reference: prekallikrein deficiency
... a role in a process called the intrinsic coagulation pathway (also called the contact activation pathway). This ... functional plasma kallikrein, which likely impairs the intrinsic coagulation pathway. Researchers suggest that this lack (deficiency) of ...
Yazdanbakhsh, Ahmad Reza; Mohammadi, Amir Sheikh; Alinejad, Abdol Azim; Hassani, Ghasem; Golmohammadi, Sohrab; Mohseni, Seyed Mohsen; Sardar, Mahdieh; Sarsangi, Vali
2016-11-01
The present study evaluates the reduction of antibiotic COD from wastewater by combined coagulation and advanced oxidation processes (AOPS). The reduction of Azithromycin COD by combined coagulation and Fenton-like processes reached a maximum 96.9% at a reaction time of 30 min, dosage of ferric chloride 120 mg/L, dosages of Fe0 and H2O2of 0.36mM/L and 0.38 mM/L, respectively. Also, 97.9% of Clarithromycin COD reduction, was achieved at a reaction time of 30 min, dosage of ferric chloride 120 mg/L, dosages of Fe0 and H2O2 of 0.3 mM/L and 0.3mM/L, respectively. The results of kinetic studies were best fitted to the pseudo first order equation. The results showed a higher rate constant value for combined coagulation and Fenton-like processes [(kap = 0.022 min-1 and half-life time of 31.5 min for Azithromycin) and (kap = 0.023 min-1 and half-life time of 30.1 min for Clarithromycin)].
A comparative analysis of selected wastewater pretreatment processes in food industry
NASA Astrophysics Data System (ADS)
Jaszczyszyn, Katarzyna; Góra, Wojciech; Dymaczewski, Zbysław; Borowiak, Robert
2018-02-01
The article presents a comparative analysis of the classical coagulation with the iron sulphate and adsorption on bentonite for the pretreatment of wastewater in the food industry. As a result of the studies, chemical oxygen demand (COD) and total nitrogen (TN) reduction were found to be comparable in both technologies, and a 29% higher total phosphorus removal efficiency by the coagulation was observed. After the coagulation and adsorption processes, a significant difference between mineral and organic fraction in the sludge was found (49% and 51% for bentonite and 28% and 72% for iron sulphate, respectively).
Sandhwar, Vishal Kumar; Prasad, Basheshwar
2017-12-01
In this work, comparative study between electrochemical processes such as electrocoagulation (EC), peroxi-coagulation (PC) and peroxi-electrocoagulation (PEC) was performed for the removal of phthalic acid (PA) and chemical oxygen demand (COD) from aqueous medium. Initially, acid treatment was studied at various pH (1-3) and temperature (10-55 °C). Subsequently, the supernatant was re-treated by electrochemical processes such as EC, PC and PEC separately. Independent parameters viz. pH, current density (CD), electrolyte concentration (m), electrode gap (g), H 2 O 2 concentration and electrolysis time (t) were optimized by Central Composite Design (CCD) for these electrochemical processes. All three processes were compared based on removal, energy consumption, kinetic analysis, operating cost and sludge characteristics. In this study, PEC process was found more efficient among EC, PC and PEC processes in order to get maximum removal, minimum energy consumption and minimum operating cost. Maximum removal of PA- 68.21%, 74.36%, 82.25% & COD- 64.79%, 68.15%, 75.21% with energy consumption - 120.95, 97.51, 65.68 (kWh/kg COD removed) were attained through EC, PC and PEC processes respectively at their corresponding optimum conditions. Results indicated that PA and COD removals are in order of PEC > PC > EC under optimum conditions. First order kinetic model was found able to describe the degradation kinetics and provided best correlation for the removal rate within the acceptable error range. Copyright © 2017 Elsevier Ltd. All rights reserved.
Imaging of blood plasma coagulation at supported lipid membranes.
Faxälv, Lars; Hume, Jasmin; Kasemo, Bengt; Svedhem, Sofia
2011-12-15
The blood coagulation system relies on lipid membrane constituents to act as regulators of the coagulation process upon vascular trauma, and in particular the 2D configuration of the lipid membranes is known to efficiently catalyze enzymatic activity of blood coagulation factors. This work demonstrates a new application of a recently developed methodology to study blood coagulation at lipid membrane interfaces with the use of imaging technology. Lipid membranes with varied net charges were formed on silica supports by systematically using different combinations of lipids where neutral phosphocholine (PC) lipids were mixed with phospholipids having either positively charged ethylphosphocholine (EPC), or negatively charged phosphatidylserine (PS) headgroups. Coagulation imaging demonstrated that negatively charged SiO(2) and membrane surfaces exposing PS (obtained from liposomes containing 30% of PS) had coagulation times which were significantly shorter than those for plain PC membranes and EPC exposing membrane surfaces (obtained from liposomes containing 30% of EPC). Coagulation times decreased non-linearly with increasing negative surface charge for lipid membranes. A threshold value for shorter coagulation times was observed below a PS content of ∼6%. We conclude that the lipid membranes on solid support studied with the imaging setup as presented in this study offers a flexible and non-expensive solution for coagulation studies at biological membranes. It will be interesting to extend the present study towards examining coagulation on more complex lipid-based model systems. Copyright © 2011 Elsevier Inc. All rights reserved.
Performance of alum and assorted coagulants in turbidity removal of muddy water
NASA Astrophysics Data System (ADS)
Malik, Qasim H.
2018-03-01
Coagulation is a primary and cost effective process in water treatment plants. Under optimum conditions, not only it effectively removes turbidity but also results in reduced sludge volume and subsequently minimizes sludge management costs. Highly turbid water from streams, canals, rivers and rain run offs was run through jar test for turbidity removal. The brown water with 250NTU turbidity when coagulated with alum and assorted coagulants proved that maximum turbidity removal was witnessed using alum dose of 0.25 g/l at ph 6 with a sedimentation time of 30 min.
Removal of Heavy Metals from Solid Wastes Leachates Coagulation-Flocculation Process
NASA Astrophysics Data System (ADS)
Yousefi, Z.; Zazouli, M. A.
The main objectives of present research were to determine heavy metals (Ni, Cd, Cr, Zn and Cu) and COD concentration in raw leachate in Esfahan (Iran) composting plant and to examine the application of coagulation-flocculation process for the treatment of raw leachates. Jar-test experiments were employed in order to determine the optimum conditions (effective dosage and optimum pH) for the removal of COD and heavy metals. Alum (aluminum sulphate) and Ferric chloride were tested as conventional coagulants. Ten times had taken sampling from leachates as standard methods in the composting plant prior to composting process. The results showed that Leachate pH was 4.3-5.9 and the average was 4.98±0.62. The concentration of Leachate pollutants were more than effluent standard limits (Environment protection Agency). And also the results indicated, Cd and Zn with concentration 0.46±0.41 and 5.81±3.69 mg L-1, had minimum and maximum levels, respectively. The results of coagulation and flocculation tests showed that in optimum conditions, the removal efficiency of heavy metals and COD by using alum were 77-91 and 21%, respectively. While removal of heavy metals and COD by ferric chloride were 68-85.5% and 28%, respectively. Also the residues of heavy metals after treatment get to under of standard limits of Iran EPA. The results have indicated optimum pH of two coagulants for leachate treatment was 6.5 and 10 and also effective coagulant dosages were 1400 and 1000 mg L-1 for alum and ferric chloride, respectively. In view of economical, ferric chloride is cost benefit. The physico-chemical process may be used as a useful pretreatment step, especially for fresh leachates.
Effect of fibrinogen on blood coagulation detected by optical coherence tomography.
Xu, Xiangqun; Teng, Xiangshuai
2015-05-21
Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d1/e) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0-8 g L(-1)); and 2) native plasma with commercial Fbg added (0-8 g L(-1)). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels.
NASA Astrophysics Data System (ADS)
Li, P.; Zhang, C. J.; Zhao, T. K.; Zhong, H.
2017-01-01
In this study, anaerobically digested slurries of livestock and poultry manure were pretreated by coagulation-sedimentation using an inorganic polymer coagulant, polyaluminum chloride (PAC). The effect of different PAC dosages on suspended solids (SS) removal and pH in the biogas slurries was assessed to provide reference values for reducing the organic load of biogas slurry in the coagulation-sedimentation process and explore the feasibility of reducing the difficulty in subsequent utilization or processing of biogas slurry. The results showed that for the pig slurry containing approximately 5000 mg/L SS, the removal rate of SS reached up to 81.6% with the coagulant dosage of 0.28 g/L PAC. For the chicken slurry containing approximately 2600 mg/L SS, the removal rate of SS was 30.2% with the coagulant dosage of 0.33 g/L PAC. The removal rate of SS in both slurries of livestock and poultry manure exhibited a downward trend with high PAC dosage. Therefore, there is a need to control the PAC dosage in practical use. The pH changed little in the two types of biogas slurries after treatment with different PAC dosages and both were in line with the standard values specified in the “Standards for Irrigation Water Quality”.
Incorporating radioactive decay into charging and coagulation of multicomponent radioactive aerosols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios
Compositional changes by the decay of radionuclides in radioactive aerosols can influence their charging state, coagulation frequency and size distribution throughout their atmospheric lifetime. The importance of such effects is unknown as they have not been considered in microphysical and global radioactivity transport studies to date. Here, we explore the effects of compositional changes on the charging efficiency and coagulation rates of aerosols using a set of kinetic equations that couple all relevant processes (decay, charging and coagulation) and their evolution over time. Compared to a coupled aggregation-tracer model for the prediction of the radioactive composition of particulates undergoing coagulation,more » our kinetic approach can provide similar results using much less central processing unit time. Altogether with other considerations, our approach is computational efficient enough to allow implementation in 3D atmospheric transport models. The decay of radionuclides and the production of decay products within radioactive aerosols may significantly affect the aerosol charging rates, and either hinder or promote the coagulation of multicomponent radioactive aerosols. Our results suggest that radiological phenomena occurring within radioactive aerosols, as well as subsequent effects on aerosol microphysics, should be considered in regional and global models to more accurately predict radioactivity transport in the atmosphere in case of a nuclear plant accident.« less
Coagulation effectiveness of graphene oxide for the removal of turbidity from raw surface water.
Aboubaraka, Abdelmeguid E; Aboelfetoh, Eman F; Ebeid, El-Zeiny M
2017-08-01
This study presents the performance of graphene oxide (GO) as a coagulant in turbidity removal from naturally and artificially turbid raw surface water. GO is considered an excellent alternative to alum, the more common coagulant used in water treatment processes, to reduce the environmental release of aluminum. Effects of GO dosage, pH, and temperature on its coagulation ability were studied to determine the ideal turbidity removal conditions. The turbidity removal was ≥95% for all levels of turbid raw surface water (20, 100, and 200 NTU) at optimum conditions. The role of alkalinity in inducing turbidity removal by GO coagulation was much more pronounced upon using raw surface water samples compared with that using artificially turbid deionized water samples. Moreover, GO demonstrated high-performance removal of biological contaminants such as algae, heterotrophic bacteria, and fecal coliform bacteria by 99.0%, 98.8% and 96.0%, respectively, at a dosage of 40 mg/L. Concerning the possible environmental release of GO into the treated water following filtration process, there was no residual GO in a wide range of pH values. The outcomes of the study highlight the excellent coagulation performance of GO for the removal of turbidity and biological contaminants from raw surface water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Incorporating radioactive decay into charging and coagulation of multicomponent radioactive aerosols
Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios; ...
2017-09-29
Compositional changes by the decay of radionuclides in radioactive aerosols can influence their charging state, coagulation frequency and size distribution throughout their atmospheric lifetime. The importance of such effects is unknown as they have not been considered in microphysical and global radioactivity transport studies to date. Here, we explore the effects of compositional changes on the charging efficiency and coagulation rates of aerosols using a set of kinetic equations that couple all relevant processes (decay, charging and coagulation) and their evolution over time. Compared to a coupled aggregation-tracer model for the prediction of the radioactive composition of particulates undergoing coagulation,more » our kinetic approach can provide similar results using much less central processing unit time. Altogether with other considerations, our approach is computational efficient enough to allow implementation in 3D atmospheric transport models. The decay of radionuclides and the production of decay products within radioactive aerosols may significantly affect the aerosol charging rates, and either hinder or promote the coagulation of multicomponent radioactive aerosols. Our results suggest that radiological phenomena occurring within radioactive aerosols, as well as subsequent effects on aerosol microphysics, should be considered in regional and global models to more accurately predict radioactivity transport in the atmosphere in case of a nuclear plant accident.« less
Wang, Jiong-Wei; Zhang, Ya-Nan; Sze, Siu Kwan; van de Weg, Sander M; Vernooij, Flora; Schoneveld, Arjan H; Tan, Sock-Hwee; Versteeg, Henri H; Timmers, Leo; Lam, Carolyn S P; de Kleijn, Dominique P V
2017-12-29
Plasma extracellular vesicles (EVs) are lipid membrane vesicles involved in several biological processes including coagulation. Both coagulation and lipid metabolism are strongly associated with cardiovascular events. Lowering very-low- and low-density lipoprotein ((V)LDL) particles via dextran sulphate LDL apheresis also removes coagulation proteins. It remains unknown, however, how coagulation proteins are removed in apheresis. We hypothesize that plasma EVs that contain high levels of coagulation proteins are concomitantly removed with (V)LDL particles by dextran sulphate apheresis. For this, we precipitated (V)LDL particles from human plasma with dextran sulphate and analyzed the abundance of coagulation proteins and EVs in the precipitate. Coagulation pathway proteins, as demonstrated by proteomics and a bead-based immunoassay, were over-represented in the (V)LDL precipitate. In this precipitate, both bilayer EVs and monolayer (V)LDL particles were observed by electron microscopy. Separation of EVs from (V)LDL particles using density gradient centrifugation revealed that almost all coagulation proteins were present in the EVs and not in the (V)LDL particles. These EVs also showed a strong procoagulant activity. Our study suggests that dextran sulphate used in LDL apheresis may remove procoagulant EVs concomitantly with (V)LDL particles, leading to a loss of coagulation proteins from the blood.
Research of combined adsorption-coagulation process in treating petroleum refinery effluent.
Wang, Bing; Shui, Yiyu; Ren, Hongyang; He, Min
2017-02-01
The petroleum refinery industry generates a significant amount of wastewater that contains a high level of organic matter, which calls for effective and costly treatments. In this research, the effectiveness of the petroleum refinery effluent (PRE) treatment with physicochemical process of combined adsorption and coagulation was evaluated. The effects of initial pH, hydraulic condition , and combined sequence of treatment process, different treating reagent types and dosages on the chemical oxygen demand (COD) removal were investigated. Additionally, the elimination efficiency of pollutant wastewater was monitored by gas chromatography-mass spectrometry (GC-MS), and Fourier transformed infrared (FT-IR) spectrophotometer was adopted to describe the structure of the wastewater. Wooden activated carbon was chosen as adsorbent at the dosage of 10 g/L as a primary treatment, and 1500 mg/L polymeric magnesium ferric sulfate was used in coagulation. Results showed that adsorption and subsequent coagulation displayed the best performance when initial pH was 9 at shear rates (G) of G1 = 65 s -1 and G2 = 20 s -1 , which reached maximal removal rate of COD and total organic carbon GC-MS testing result revealed that adsorption was effective in phenols and iso-alkanes removal, whereas coagulation was good at removing esters and n-alkanes.
Polyaluminium chloride as an alternative to alum for the direct filtration of drinking water.
Zarchi, Idit; Friedler, Eran; Rebhun, Menahem
2013-01-01
The efficiency of various polyaluminium chloride coagulants (PACls) was compared to the efficiency of aluminium sulfate (alum) in the coagulation-flocculation process preceding direct filtration in drinking water treatment. The comparative study consisted of two separate yet complementary series of experiments: the first series included short (5-7 h) and long (24 h) filter runs conducted at a pilot filtration plant equipped with large filter columns that simulated full-scale filters. Partially treated surface water from the Sea of Galilee, characterized by very low turbidity (-1 NTU), was used. In the second series of experiments, speciation of aluminium in situ was investigated using the ferron assay method. Results from the pilot-scale study indicate that most PACls were as or more efficient a coagulant as alum for direct filtration of surface water without requiring acid addition for pH adjustment and subsequent base addition for re-stabilizing the water. Consequently, cost analysis of the chemicals needed for the process showed that treatment with PACl would be significantly less costly than treatment with alum. The aluminium speciation experiments revealed that the performance of the coagulant is more influenced by the species present during the coagulation process than those present in the original reagents.
[Effect of UV Light Radiation on the Coagulation of Chlorella and Its Mechanism].
Wang, Wen-dong; Zhang, Ke; Xu, Hong-bin; Liu, Guo-qi
2016-01-15
Considering algae were difficult to be effectively removed in conventional water treatment process, UV radiation was used to enhance the coagulation of algae in this study. The results showed that with the increase of radiation time, the removal rates of both algae and turbidity experienced a decrease after an increase, and reached their maximum values at 50 min. When the dosage of PAC was 5 mg x L(-1), the removal rates of algae and turbidity of the radiated sample were 20.1% and 18% higher than the blank sample, respectively. When pH ranged from 6 to 9, the coagulation efficiency varied little. At pH 8 and with a radiation time of 50 min, the removal rates of algae and turbidity reached 93.5% and 90.6%, respectively. Meanwhile, the Zeta potential reached the maximum, and the algae generated extracellular organic matter, which favored the subsequent coagulation. After radiated for 60 min, the algal cells was destroyed, leading to a release of intracellular organic matter into the solution. Accordingly, the Zeta potential decreased, which had a negative effect on the subsequent coagulation process.
Birjandi, Noushin; Younesi, Habibollah; Bahramifar, Nader; Ghafari, Shahin; Zinatizadeh, Ali Akbar; Sethupathi, Sumathi
2013-01-01
The application of coagulation-flocculation (CF) process for treating the paper-recycling wastewater in jar-test experiment was employed. The purpose of the study was aimed to examine the efficiency of alum and poly aluminum chloride (PACl) in combination with a cationic polyacrylamide (C-PAM) in removal of chemical oxygen demand (COD) and turbidity from paper-recycling wastewater. Optimization of CF process were performed by varying independent parameters (coagulants dosage, flocculants dosage, initial COD and pH) using a central composite design (CCD) under response surface methodology (RSM). Maximum set required 4.5 as pH, 40 mg/L coagulants dosage and 4.5 mg/L flocculants dosage at which gave 92% reduction of turbidity, 97% of COD removal and SVI 80 mL/g. The best coagulant and flocculants were alum and chemfloc 3876 at dose of 41 and 7.52 mg/L, respectively, correspondingly at pH of 6.85. These conditions gave 91.30% COD and 95.82% turbidity removals and 12 mL/g SVI.
Optimizing coagulation-adsorption for haloform and TOC (Total Organic Carbon) reduction
NASA Astrophysics Data System (ADS)
Semmens, M. J.; Hohenstein, G.; Staples, A.; Norgaard, G.; Ayers, K.; Tyson, M. P.
1983-05-01
The removal of organic matter from Mississippi River water by coagulation and softening processes and the influence of operating parameters upon the removal process are examined. Furthermore, since activated carbon is typically employed to reduce organic concentrations, the effectiveness of various pretreatments are evaluated for their impact upon carbon bed life and the product water quality.
Charging and discharging of single colloidal particles at oil/water interfaces
Gao, Peng; Xing, XiaoChen; Li, Ye; Ngai, To; Jin, Fan
2014-01-01
The physical behavior of solid colloids trapped at a fluid-fluid interface remains in itself an open fundamental issue. Here, we show that the gradients of surface tension can induce particles to jet towards the oil/water interface with velocities as high as ≈ 60 mm/s when particle suspensions come in contact with the interface. We hypothesize that rubbing between the particles and oil lead to the spontaneous accumulation of negative charges on the hemisphere of those interfacial particles that contact the oil phase by means of triboelectrification. The charging process is highly dependent on the sliding distances, and gives rise to long-ranged repulsions that protect interfacial particles from coagulating at the interface by the presence of electrolyte. These triboelectric charges, however, are compensated within several hours, which affect the stability of interfacial particles. Importantly, by charging different kinds of colloidal particles using various spreading solvents and dispersion methods, we have demonstrated that charging and discharging of single colloidal particles at oil/water interfaces impacts a broad range of dynamical behavior. PMID:24786477
Manuelian, C L; Visentin, G; Boselli, C; Giangolini, G; Cassandro, M; De Marchi, M
2017-09-01
Milk coagulation and acidity traits are important factors to inform the cheesemaking process. Those traits have been deeply studied in bovine milk, whereas scarce information is available for buffalo milk. However, the dairy industry is interested in a method to determine milk coagulation and acidity features quickly and in a cost-effective manner, which could be provided by Fourier-transform mid-infrared (FT-MIR) spectroscopy. The aim of this study was to evaluate the potential of FT-MIR to predict coagulation and acidity traits of Mediterranean buffalo milk. A total of 654 records from 36 herds located in central Italy with information on milk yield, somatic cell score, milk chemical composition, milk acidity [pH, titratable acidity (TA)], and milk coagulation properties (rennet coagulation time, curd firming time, and curd firmness) were available for statistical analysis. Reference measures of milk acidity and coagulation properties were matched with milk spectral information, and FT-MIR prediction models were built using partial least squares regression. The data set was divided into a calibration set (75%) and a validation set (25%). The capacity of FT-MIR spectroscopy to correctly classify milk samples based on their renneting ability was evaluated by a canonical discriminant analysis. Average values for milk coagulation traits were 13.32 min, 3.24 min, and 39.27 mm for rennet coagulation time, curd firming time, and curd firmness, respectively. Milk acidity traits averaged 6.66 (pH) and 7.22 Soxhlet-Henkel degrees/100 mL (TA). All milk coagulation and acidity traits, except for pH, had high variability (17 to 46%). Prediction models of coagulation traits were moderately to scarcely accurate, whereas the coefficients of determination of external validation were 0.76 and 0.66 for pH and TA, respectively. Canonical discriminant analysis indicated that information on milk coagulating ability is present in the MIR spectra, and the model correctly classified as noncoagulating the 91.57 and 67.86% of milk samples in the calibration and validation sets, respectively. In conclusion, our results can be relevant to the dairy industry to classify buffalo milk samples before processing. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Rakruam, Pharkphum; Wattanachira, Suraphong
2014-03-01
This research was aimed at investigating the reduction of DOM fractions and their trihalomethane formation potential (THMFP) by in-line coagulation with 0.1 μm ceramic membrane filtration. The combination of ceramic membrane filtration with a coagulation process is an alternative technology which can be applied to enhance conventional coagulation processes in the field of water treatment and drinking water production. The Ping River water (high turbidity water) was selected as the raw surface water because it is currently the main raw water source for water supply production in the urban and rural areas of Chiang Mai Province. From the investigation, the results showed that the highest percent reductions of DOC, UV-254, and THMFP (47.6%, 71.0%, and 67.4%, respectively) were achieved from in-line coagulation with ceramic membrane filtration at polyaluminum chloride dosage 40 mg/L. Resin adsorption techniques were employed to characterize the DOM in raw surface water and filtered water. The results showed that the use of a ceramic membrane with in-line coagulation was able to most efficiently reduce the hydrophobic fraction (HPOA) (68.5%), which was then followed by the hydrophilic fraction (HPIA) (49.3%). The greater mass DOC reduction of these two fractions provided the highest THMFP reductions (55.1% and 37.2%, respectively). Furthermore, the in-line coagulation with ceramic membrane filtration was able to reduce the hydrophobic (HPOB) fraction which is characterized by high reactivity toward THM formation. The percent reduction of mass DOC and THMFP of HPOB by in-line coagulation with ceramic membrane filtration was 45.9% and 48.0%, respectively. Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
Arango, O; Trujillo, A J; Castillo, M
2013-04-01
The objective of this study was to evaluate the effect of inulin as a fat replacer on the rheological properties, coagulation kinetics, and syneresis of milk gels. A randomized factorial design, replicated 3 times, with 3 inulin concentrations (0, 3, and 6%), 2 levels of fat (<0.2 and 1.5%), and 3 coagulation temperatures (27, 32, and 37°C) was used. The coagulation process was monitored using near-infrared spectrometry, small amplitude oscillatory rheometry, and visual coagulation indexes. The syneresis was evaluated by volumetric methods. Inulin addition increased the rates of aggregation and curd firming reactions in the casein gels. The observed effect, which was more evident on the aggregation reaction, depended on the concentration of inulin and the coagulation temperature. Addition of 6% inulin reduced the clotting time by approximately 26% and the time at which the gel reached a storage modulus equal to 30 Pa by approximately 36%. The optical parameter R'max, defined as the maximum value of change in light backscatter profile/change in time (where R' = dR/dt), was used to calculate an approximation of the temperature coefficients (Q10) for milk coagulation. Increasing fat concentration induced a consistent increase in all the optical, rheological, and visual parameters studied, although the observed trend was not statistically significant. The addition of inulin at a level of 6% produced a reduction in syneresis and increased the curd yield by approximately 30%. It was concluded that the addition of inulin affects the kinetics of milk coagulation and the cutting time and, therefore, the use of inline sensors such as near-infrared spectrometry may be necessary for optimal process control. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Integrated process for the removal of emulsified oils from effluents in the steel industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benito, J.M.; Rios, G.; Gutierrez, B.
1999-11-01
Emulsified oils contained in aqueous effluents from cold-rolling mills of the steel industry can be effectively removed via an integrated process consisting of a coagulation/flocculation stage followed by ultrafiltration of the resulting aqueous phase. The effects of CaCl{sub 2}, NaOH, and lime on the stability of different industrial effluents were studied in the coagulation experiments. The flocculants tested were inorganic prehydrolyzed aluminum salts and quaternary polyamines. Ultrafiltration of the aqueous phase from the coagulation/flocculation stage was carried out in a stirred cell using Amicon PM30 and XM300 organic membranes. Permeate fluxes were measured for industrial effluents to which the indicatedmore » coagulants and flocculants had been added. Oil concentrations in the permeate were 75% lower than the limits established by all European Union countries. Complete regeneration of the membrane was accomplished with an aqueous solution of a commercial detergent.« less
Continuous process to produce lithium-polymer batteries
Chern, Terry Song-Hsing; Keller, David Gerard; MacFadden, Kenneth Orville
1998-01-01
Solid polymer electrolytes are extruded with active electrode material in a continuous, one-step process to form composite electrolyte-electrodes ready for assembly into battery cells. The composite electrolyte-electrode sheets are extruded onto current collectors to form electrodes. The composite electrodes, as extruded, are electronically and ionically conductive. The composite electrodes can be overcoated with a solid polymer electrolyte, which acts as a separator upon battery assembly. The interface between the solid polymer electrolyte composite electrodes and the solid polymer electrolyte separator has low resistance.
Liburdi, Katia; Emiliani Spinelli, Sara; Benucci, Ilaria; Lombardelli, Claudio; Esti, Marco
2018-01-15
The aim of this study was to develop a bioreactor design for continuous milk coagulation using a biocatalyst composed of immobilized animal and vegetable rennet on aminated magnetic particles, which has been proven to be an appropriate carrier for enzyme immobilization. Calf and vegetable (Cynara cardunculus) rennets were covalently immobilized on CLEA® magnetic supports and the immobilization procedure was optimized in batch mode, by evaluating protein loading, caseinolytic activity and the coagulation properties of skim milk powder and cow's milk. Subsequently the optimal temperature of immobilized coagulant was defined and a technically-friendly enzyme bioreactor was developed in order to carry out a continuous milk coagulation process with the aim of producing soft cheese. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wang, Chengjin; Alpatova, Alla; McPhedran, Kerry N; Gamal El-Din, Mohamed
2015-09-01
This study investigated the application of polyaluminum chloride (PACl) for the treatment of the oil sands process-affected water (OSPW). These coagulants are commonly used in water treatment with the most effective species reported to be Al13. PACl with 83.6% Al13 was synthesized using the slow base titration method and compared with a commercially available PACl in terms of aluminum species distribution, coagulation/flocculation (CF) performance, floc morphology, and contaminant removal. Both coagulants were effective in removing suspended solids, achieving over 96% turbidity removal at all applied coagulant doses (0.5-3.0 mM Al). The removal efficiencies of metals varied among different metals depending on their pKa values with metal cations having pKa values (Fe, Al, Ga, and Ti) below OSPW pH of 6.9-8.1 (dose dependent) being removed by more than 90%, while cations with higher pKa values (K, Na, Ca, Mg and Ni) had removals of less than 40%. Naphthenic acids were not removed due to their low molecular weights, negative charges, and hydrophilic characteristics at the OSPW pH. At the highest applied coagulant dose of 3.0 mM Al, the synthetic PACl reduced Vibrio fischeri inhibition effect to 43.3 ± 3.0% from 49.5 ± 0.4% in raw OSPW. In contrast, no reduction of toxicity was found for OSPW treated with the commercial PACl. Based on water quality and floc analyses, the dominant CF mechanism for particle removal during OSPW treatment was considered to be enmeshment in the precipitates (i.e., sweep flocculation). Overall, the CF using synthesized PACl can be a valuable pretreatment process for OSPW to create wastewater that is more easily treated by downstream processes. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ceramic electrolyte coating and methods
Seabaugh, Matthew M [Columbus, OH; Swartz, Scott L [Columbus, OH; Dawson, William J [Dublin, OH; McCormick, Buddy E [Dublin, OH
2007-08-28
Aqueous coating slurries useful in depositing a dense coating of a ceramic electrolyte material (e.g., yttrium-stabilized zirconia) onto a porous substrate of a ceramic electrode material (e.g., lanthanum strontium manganite or nickel/zirconia) and processes for preparing an aqueous suspension of a ceramic electrolyte material and an aqueous spray coating slurry including a ceramic electrolyte material. The invention also includes processes for depositing an aqueous spray coating slurry including a ceramic electrolyte material onto pre-sintered, partially sintered, and unsintered ceramic substrates and products made by this process.
Electrolytic process for preparing uranium metal
Haas, Paul A.
1990-01-01
An electrolytic process for making uranium from uranium oxide using Cl.sub.2 anode product from an electrolytic cell to react with UO.sub.2 to form uranium chlorides. The chlorides are used in low concentrations in a melt comprising fluorides and chlorides of potassium, sodium and barium in the electrolytic cell. The electrolysis produces Cl.sub.2 at the anode that reacts with UO.sub.2 in the feed reactor to form soluble UCl.sub.4, available for a continuous process in the electrolytic cell, rather than having insoluble UO.sub.2 fouling the cell.
NASA Astrophysics Data System (ADS)
Xiaoxu, SUN; Jin, XU; Xingyu, LI
2017-12-01
In this paper dyeing waste water was simulated by reactive brilliant blue XBR, activated carbon adsorption process, coagulation process and chemical oxidation process were used to treat dyeing waste water. In activated carbon adsorption process and coagulation process, the water absorbance values were measured. The CODcr value of water was determined in Fenton chemical oxidation process. Then, the decolorization rate and COD removal rate were calculated respectively. The results showed that the optimum conditions of activated carbon adsorption process were as follows: pH=2, the dosage of activated carbon was 1.2g/L, the adsorption reaction time was 60 min, and the average decolorization rate of the three parallel experiments was 85.30%. The optimum conditions of coagulation experiment were as follows: pH=8~9, PAC dosage was 70mg/L, stirring time was 20min, standing time was 45min, the average decolorization rate of the three parallel experiments was 74.48%. The optimum conditions for Fenton oxidation were Fe2+ 0.05g/L, H2O2 (30%) 14mL/L, pH=3, reaction time 40min. The average CODcr removal rate was 69.35% in three parallel experiments. It can be seen that in the three methods the activated carbon adsorption treatment of dyeing wastewater was the best one.
Fate of cyanobacteria and their metabolites during water treatment sludge management processes.
Ho, Lionel; Dreyfus, Jennifer; Boyer, Justine; Lowe, Todd; Bustamante, Heriberto; Duker, Phil; Meli, Tass; Newcombe, Gayle
2012-05-01
Cyanobacteria and their metabolites are an issue for water authorities; however, little is known as to the fate of coagulated cyanobacterial-laden sludge during waste management processes in water treatment plants (WTPs). This paper provides information on the cell integrity of Anabaena circinalis and Cylindrospermopsis raciborskii during: laboratory-scale coagulation/sedimentation processes; direct filtration and backwashing procedures; and cyanobacterial-laden sludge management practices. In addition, the metabolites produced by A. circinalis (geosmin and saxitoxins) and C. raciborskii (cylindrospermopsin) were investigated with respect to their release (and possible degradation) during each of the studied processes. Where sedimentation was used, coagulation effectively removed cyanobacteria (and intracellular metabolites) without any considerable exertion on coagulant demand. During direct filtration experiments, cyanobacteria released intracellular metabolites through a stagnation period, suggesting that more frequent backwashing of filters may be required to prevent floc build-up and metabolite release. Cyanobacteria appeared to be protected within the flocs, with minimal damage during backwashing of the filters. Within coagulant sludge, cyanobacteria released intracellular metabolites into the supernatant after 3d, even though cells remained viable up to 7d. This work has improved the understanding of cyanobacterial metabolite risks associated with management of backwash water and sludge and is likely to facilitate improvements at WTPs, including increased monitoring and the application of treatment strategies and operational practices, with respect to cyanobacterial-laden sludge and/or supernatant recycle management. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Chan Moon; Parnichkun, Manukid
2017-11-01
Coagulation is an important process in drinking water treatment to attain acceptable treated water quality. However, the determination of coagulant dosage is still a challenging task for operators, because coagulation is nonlinear and complicated process. Feedback control to achieve the desired treated water quality is difficult due to lengthy process time. In this research, a hybrid of k-means clustering and adaptive neuro-fuzzy inference system ( k-means-ANFIS) is proposed for the settled water turbidity prediction and the optimal coagulant dosage determination using full-scale historical data. To build a well-adaptive model to different process states from influent water, raw water quality data are classified into four clusters according to its properties by a k-means clustering technique. The sub-models are developed individually on the basis of each clustered data set. Results reveal that the sub-models constructed by a hybrid k-means-ANFIS perform better than not only a single ANFIS model, but also seasonal models by artificial neural network (ANN). The finally completed model consisting of sub-models shows more accurate and consistent prediction ability than a single model of ANFIS and a single model of ANN based on all five evaluation indices. Therefore, the hybrid model of k-means-ANFIS can be employed as a robust tool for managing both treated water quality and production costs simultaneously.
Slaughterhouse Wastewater Treatment by Combined Chemical Coagulation and Electrocoagulation Process
Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein
2012-01-01
Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD5 removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater. PMID:22768233
Enhancement of sedimentation and coagulation with static magnetic field
NASA Astrophysics Data System (ADS)
Zieliński, Marcin; Dębowski, Marcin; Hajduk, Anna; Rusanowska, Paulina
2017-11-01
The static magnetic field can be an alternative method for wastewater treatment. It has been proved that this physical factor, accelerates the biochemical processes, catalyzes advanced oxidation, intensifies anaerobic and aerobic processes or reduces swelling of activated sludge. There are also reports proving the positive impact of the static magnetic field on the coagulation and sedimentation, as well as the conditioning and dewatering of sludge. In order to be applied in larger scale the published results should be verified and confirmed. In the studies, the enhancement of sedimentation by the static magnetic field was observed. The best sedimentation was noted in the experiment, where magnetizers were placed on activated sludge bioreactor and secondary settling tank. No effect of the static magnetic field on coagulation with the utilization of PIX 113 was observed. However, the static magnetic field enhanced coagulation with the utilization of PAX-XL9. The results suggest that increased sedimentation of colloids and activated sludge, can in practice mean a reduction in the size of the necessary equipment for sedimentation with an unchanged efficiency of the process.
Slaughterhouse wastewater treatment by combined chemical coagulation and electrocoagulation process.
Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein
2012-01-01
Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD(5) removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.
Han, Qi; Yan, Han; Zhang, Feng; Xue, Nan; Wang, Yan; Chu, Yongbao; Gao, Baoyu
2015-10-30
Due to concerns over health risk of disinfection byproducts (DBPs), removal of trihalomethanes (THMs) precursor from bio-treated wastewater by coagulation and adsorption was investigated in this study. Ultrafiltration (UF) membranes and nonionic resins were applied to fractionate THMs precursor into various molecular weight (MW) fractions and hydrophobic/hydrophilic fractions. Characteristics of coagulated water and adsorbed water were evaluated by the three-dimensional excitation and emission matrix (3DEEM) fluorescence spectroscopy. Results showed that coagulation and adsorption were suitable for removing different hydrophobic/hydrophilic and fluorescent fractions. Coagulation decreased THMs concentration in hydrophobic acids (HoA) fraction from 59 μg/L to 39 μg/L, while the lowest THMs concentration (9 μg/L) in hydrophilic substances (HiS) fraction was obtained in adsorbed water. However, both coagulation and adsorption were ineffective for removing fractions with MW<5 kDa. Although coagulation and adsorption processes could reduce THMs formation, some specific THMs formation potential (STHMFP) in residual dissolved organic matter (DOM) fractions increased in this study. Hydrophobic acid and hydrophilic fractions increased after coagulation treatment, and low MW and hydrophobic fractions increased after adsorption treatment. In addition, active carbon adsorbed more organic matter than coagulant, but brominated disinfection byproducts (Br-DBPs) in adsorbed water turned to the major THMs species after chlorination. Copyright © 2015 Elsevier B.V. All rights reserved.
ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation
Chen, Da; Zhang, Zhen; Ma, Jilong; Wang, Wei
2017-01-01
Miniaturized and rapid blood coagulation assay technologies are critical in many clinical settings. In this paper, we present a ZnO film bulk acoustic resonator for the kinetic analysis of human blood coagulation. The resonator operated in thickness shear resonance mode at 1.4 GHz. When the resonator contacted the liquid environment, the viscous loading effect was considered as the additional resistance and inductance in the equivalent circuits, resulting in a linear relationship with a slope of approximately −217 kHz/cP between the liquid viscosity and the frequency of the resonator. The downshift of the resonant frequency and the viscosity change during the blood coagulation were correlated to monitor the coagulation process. The sigmoidal trend was observed in the frequency response for the blood samples activated by thromboplastin and calcium ions. The coagulation kinetics involving sequential phases of steady reaction, growth and saturation were revealed through the time-dependent frequency profiles. The enzymatic cascade time, the coagulation rate, the coagulation time and the clot degree were provided by fitting the time-frequency curves. The prothrombin times were compared with the results measured by a standard coagulometer and show a good correlation. Thanks to the excellent potential of integration, miniaturization and the availability of direct digital signals, the film bulk acoustic resonator has promising application for both clinical and personal use coagulation testing technologies. PMID:28467374
Improving the Efficiency of Natural Raw Water Pretreatment at Thermal Power Stations
NASA Astrophysics Data System (ADS)
Dremicheva, E. S.
2018-02-01
In the treatment of make-up water for thermal power stations (TPS) and heat networks, raw water from surface water bodies is used. It contains organic and mineral pollutants in the form of particulates or colloids. Coagulation and flocculation are reagent methods for removing these pollutants from water. Chemicals are used to assist in the formation of large structured flakes that are removed easily from water. The Kuibyshev water reservoir was selected as the object of investigation. Basic physical and chemical properties of the raw water are presented. The application of various coagulating agents, their mixtures in different proportions, and flocculating agents for clarifying the Volga water was examined. The required dose of a coagulant or flocculant was determined based on test coagulation of the treated water. Aluminum sulfate and iron (III) chloride were used a coagulant, and Praestol 2500 (nonionic) as a flocculant. A method of enhancement of coagulation and flocculation by injecting air into the treated water is examined. The results of experimental investigation of the effect of water treatment method on water quality indices, such as alkalinity, pH, iron content, suspended material content, and permanganate value, are presented. It is demonstrated that joint use of ironand aluminum containing coagulation agents brings the coagulation conditions closer to the optimum ones. Aeration does not affect the coagulation process. The methods for supplying air to a clarifier are proposed for practical implementation.
Effectiveness and mechanism of potassium ferrate(VI) preoxidation for algae removal by coagulation.
Ma, Jun; Liu, Wei
2002-02-01
Jar tests were conducted to evaluate the effectiveness of potassium ferrate preoxidation on algae removal by coagulation. Laboratory studies demonstrated that pretreatment with potassium ferrate obviously enhanced the algae removal by coagulation with alum [Al2(SO4)3 . 18H2O]. Algae removal efficiency increased remarkably when the water was pretreated with ferrate. A very short time of preoxidation was enough to achieve substantial algae removal efficiency, and the effectiveness was further increased at a prolonged pretreatment time. Pretreatment with ferrate resulted in a reduction of alum dosage required to cause an efficient coagulation for algae removal. The obvious impact of cell architecture by potassium ferrate was found through scanning electron microscopy. Upon oxidation with ferrate. the cells were inactivated and some intracellular and extracelluar components were released into the water, which may be helpful to the coagulation by their bridging effect. Efficient removal of algae by potassium ferrate preoxidation is believed to be a consequence of several process mechanisms. Ferrate preoxidation inactivated algae, induced the formation of coagulant aid, which are the cellular components secreted by algal cells. The coagulation was also improved by increasing particle concentration in water, because of the formation of the intermediate forms of precipitant iron species during preoxidation. In addition, it was also observed that ferrate preoxidation caused algae agglomerate formation before the addition of coagulant, the subsequent application of alum resulted in further coagulation.
Dataset on the cost estimation for spent filter backwash water (SFBW) treatment.
Ebrahimi, Afshin; Mahdavi, Mokhtar; Pirsaheb, Meghdad; Alimohammadi, Fariborz; Mahvi, Amir Hossein
2017-12-01
The dataset presented in this article are related to the research article entitled "Hybrid coagulation-UF processes for spent filter backwash water treatment: a comparison studies for PAFCl and FeCl 3 as a pre-treatment" (Ebrahimi et al., 2017) [1]. This article reports the cost estimation for treating produced spent filter backwash water (SFBW) during water treatment in Isfahan- Iran by various methods including primary sedimentation, coagulation & flocculation, second clarification, ultra filtration (UF) and recirculation of settled SFBW to water treatment plant (WTP) entrance. Coagulation conducted by PAFCl and FeCl 3 as pre polymerized and traditional coagulants. Cost estimation showed that contrary to expectations, the recirculation of settled SFBW to WTP entrance is more expensive than other method and it costs about $ 37,814,817.6. Versus the cheapest option related to separate primary sedimentation, coagulation & flocculation in WTP. This option cost about $ 4,757,200 and $ 950,213 when FeCl3 and PAFCl used as coagulant, respectively.
Sukhin, I A; Khudets'kyĭ, I Iu; Kachan, S H; Bilylovets', O M
2013-01-01
There are adduced the results of experimental operations on mongrel rabbits with dissection and coagulation of the liver and the spleen, using highly temperature coagulation apparatuses of various kinds. There was established, that while application of various highly temperature technologies a typical process occurs, consisting of the heat spreading inside the organ. The temperature raising grade depends on the method and duration of the impact.
Continuous process to produce lithium-polymer batteries
Chern, T.S.H.; Keller, D.G.; MacFadden, K.O.
1998-05-12
Solid polymer electrolytes are extruded with active electrode material in a continuous, one-step process to form composite electrolyte-electrodes ready for assembly into battery cells. The composite electrolyte electrode sheets are extruded onto current collectors to form electrodes. The composite electrodes, as extruded, are electronically and ionically conductive. The composite electrodes can be over coated with a solid polymer electrolyte, which acts as a separator upon battery assembly. The interface between the solid polymer electrolyte composite electrodes and the solid polymer electrolyte separator has low resistance. 1 fig.
Analysis of aggregation of platelets in thrombosis
NASA Astrophysics Data System (ADS)
Ahuja, Suresh
Platelets are key players in thrombus formation by first rolling over collagen bound von Willebrand factor followed by formation of a stable interaction with collagen. The first adhered platelets bind additional platelets until the whole injury is sealed off by a platelet aggregate. The coagulation system stabilizes the formed platelet plug by creating a tight fibrin network, and then wound contraction takes place because of morphological changes in platelets. Coagulation takes place by platelet activation and aggregation mainly through fibrinogen polymerization into fibrin fibers. The process includes multiple factors, such as thrombin, plasmin, and local shear-rate which regulate and control the process. Coagulation can be divided into two pathways: the intrinsic pathway and the extrinsic pathway. The intrinsic pathway is initiated by the exposure of a negatively charged. It is able to activate factor XII, using a complex reaction that includes prekallikrein and high-molecular-weight kininogen as cofactors.. Thrombin is the final enzyme that is needed to convert fibrinogen into fibrin. The extrinsic pathway starts with the exposure of tissue factor to the circulating blood, which is the major initiator of coagulation. There are several feedback loops that reinforce the coagulation cascade, resulting in large amounts of thrombin. It is dependent on the presence of pro-coagulant surfaces of cells expressing negatively charged phospholipids--which include phosphatidylserine (PS)--on their outer membrane. PS-bearing surfaces are able to increase the efficiency of the reactions by concentrating and co-localizing coagulation factors.. Aggregation of platelets are analyzed and compared to adhesion of platelet to erythrocyte and to endothelial cells. This abstract is replacing MAR16-2015-020003.
Riley, Paul W.; Gallea, Benoit; Valcour, Andre
2017-01-01
Background: Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. Methods: The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Results: Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. Conclusions: To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process. PMID:28706751
Riley, Paul W; Gallea, Benoit; Valcour, Andre
2017-01-01
Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process.
NASA Astrophysics Data System (ADS)
Ali Shah, Syed Farman; Shah, Abdul Karim; Mehdi, Ahmad; Memon, Aziza Aftab; Harijan, Khanji; Ali, Zeenat M.
2012-05-01
Textile dye manufacture processes are known as the most polluting chemical processes of industrial sectors of the world. Colored wastewaters along with many polluting agents are troublesome. They are heavily polluted with dyes, textile auxiliaries and chemicals. Current study applies a coupled technology for wastewater treatment. Combined coagulation-adsorption process was utilized for treatment of complex nature effluents of dyes, binder emulsion, pigments and textile chemicals plants at Clariant Pakistan. Cost effective coagulant and adsorbent was selected by using waste material from a power generation unit of Water and Power Development Authority (WAPDA), Pakistan. The treated effluent could be reused. Alum+ Activated Carbon, Ferrous sulfate+ Activated Carbon, Ferric chloride + Activated Carbon. Almost complete decolourization was achieved along with reduction in COD up to 65%. Pre and post treatment, TDS, COD, Turbidity and suspended solids were improved.
Allen, Bruce C.; Andres, Kara L.; Ehresman, David J.; Falvo, Ria; Provencher, Anne; Olsen, Geary W.; Butenhoff, John L.
2017-01-01
Abstract An oral dose study with perfluorooctanesulfonate (PFOS) was undertaken to identify potential associations between serum PFOS and changes in serum clinical chemistry parameters in purpose-bred young adult cynomolgus monkeys (Macaca fascicularis). In this study, control group (n = 6/sex) was sham-dosed with vehicle (0.5% Tween 20 and 5% ethanol in water), low-dose group (n = 6/sex) received 1 single K+PFOS dose (9 mg/kg), and high-dose group (n = 4–6/sex) received 3 separate K+ PFOS doses (11–17.2 mg/kg). Monkeys were given routine checkups and observed carefully for health problems on a daily basis. Scheduled blood samples were drawn from all monkeys prior to, during, and after K+PFOS administration for up to 1 year and they were analyzed for PFOS concentrations and clinical chemistry markers for coagulation, lipids, hepatic, renal, electrolytes, and thyroid-related hormones. No mortality occurred during the study. All the monkeys were healthy, gained weight, and were released back to the colony at the end of the study. The highest serum PFOS achieved was approximately 165 μg/ml. When compared with time-matched controls, administration of K+PFOS to monkeys did not result in any toxicologically meaningful or clinically relevant changes in serum clinical measurements for coagulation, lipids, hepatic, renal, electrolytes, and thyroid-related hormones. A slight reduction in serum cholesterol (primarily the high-density lipoprotein fraction), although not toxicologically significant, was observed. The corresponding lower-bound fifth percentile benchmark concentrations (BMCL1sd) were 74 and 76 μg/ml for male and female monkeys, respectively. Compared to the 2013–2014 geometric mean serum PFOS level of 4.99 ng/ml (0.00499 μg/ml) in US general population reported by CDC NHANES, this represents 4 orders of magnitude for margin of exposure. PMID:28115654
Isidro, J; Llanos, J; Sáez, C; Lobato, J; Cañizares, P; Rodrigo, M A
2018-09-15
This work presents the design and evaluation of a new concept of pre-disinfection treatment that is especially suited for highly polluted surface water and is based on the combination of coagulation-flocculation, lamellar sedimentation and filtration into a single-column unit, in which the interconnection between treatments is an important part of the overall process. The new system, the so-called PREDICO (PRE-DIsinfection Column) system, was built with low-cost consumables from hardware stores (in order to promote in-house construction of the system in poor countries) and was tested with a mixture of 20% raw wastewater and 80% surface water (in order to simulate an extremely bad situation). The results confirmed that the PREDICO system helps to avoid fouling in later electro-disinfection processes and attains a remarkable degree of disinfection (3-4 log units), which supplements the removal of pathogens attained by the electrolytic cell (more than 4 log units). The most important sizing parameters for the PREDICO system are the surface loading rate (SLR) and the hydraulic residence time (HRT); SLR values under 20 cm min -1 and HRT values over 13.6 min in the PREDICO system are suitable to warrant efficient performance of the system. Copyright © 2018 Elsevier Ltd. All rights reserved.
Tamayo, Diana; Hernández, Orville; Muñoz-Cadavid, Cesar; Cano, Luz Elena; González, Angel
2013-01-01
The infectious process starts with an initial contact between pathogen and host. We have previously demonstrated that Paracoccidioides brasiliensis conidia interact with plasma proteins including fibrinogen, which is considered the major component of the coagulation system. In this study, we evaluated the in vitro capacity of P. brasiliensis conidia to aggregate with plasma proteins and compounds involved in the coagulation system. We assessed the aggregation of P. brasiliensis conidia after incubation with human serum or plasma in the presence or absence of anticoagulants, extracellular matrix (ECM) proteins, metabolic and protein inhibitors, monosaccharides and other compounds. Additionally, prothrombin and partial thromboplastin times were determined after the interaction of P. brasiliensis conidia with human plasma. ECM proteins, monosaccharides and human plasma significantly induced P. brasiliensis conidial aggregation; however, anticoagulants and metabolic and protein inhibitors diminished the aggregation process. The extrinsic coagulation pathway was not affected by the interaction between P. brasiliensis conidia and plasma proteins, while the intrinsic pathway was markedly altered. These results indicate that P. brasiliensis conidia interact with proteins involved in the coagulation system. This interaction may play an important role in the initial inflammatory response, as well as fungal disease progression caused by P. brasiliensis dissemination. PMID:23827999
Zhang, Zhenchao
2017-12-01
In this study, a combined process was developed that included micro-electrolysis, Fenton oxidation and coagulation to treat oilfield fracturing wastewater. Micro-electrolysis and Fenton oxidation were applied to reduce chemical oxygen demand (COD) organic load and to enhance organic components gradability, respectively. Orthogonal experiment were employed to investigate the influence factors of micro-electrolysis and Fenton oxidation on COD removal efficiency. For micro-electrolysis, the optimum conditions were: pH, 3; iron-carbon dosage, 50 mg/L; mass ratio of iron-carbon, 2:3; reaction time, 60 min. For Fenton oxidation, a total reaction time of 90 min, a H 2 O 2 dosage of 12 mg/L, with a H 2 O 2 /Fe 2+ mole ratio of 30, pH of 3 were selected to achieve optimum oxidation. The optimum conditions in coagulation process: pH, cationic polyacrylamide dosage, mixing speed and time is 4.3, 2 mg/L, 150 rpm and 30 s, respectively. In the continuous treatment process under optimized conditions, the COD of oily wastewater fell 56.95%, 46.23%, 30.67%, respectively, from last stage and the total COD removal efficiency reached 83.94% (from 4,314 to 693 mg/L). In the overall treatment process under optimized conditions, the COD of oily wastewater was reduced from 4,314 to 637 mg/L, and the COD removal efficiency reached 85.23%. The contribution of each stage is 68.45% (micro-electrolysis), 24.07% (Fenton oxidation), 7.48% (coagulation), respectively. Micro-electrolysis is the uppermost influencing process on COD removal. Compared with the COD removal efficiency of three processes on raw wastewater under optimized conditions: the COD removal efficiency of single micro-electrolysis, single Fenton oxidation, single coagulation is 58.34%, 44.88% and 39.72%, respectively. Experiments proved the effect of combined process is marvelous and the overall water quality of the final effluent could meet the class III national wastewater discharge standard of petrochemical industry of China (GB8978-1996).
Study of coagulation processes of selected humic acids under copper ions influence*
NASA Astrophysics Data System (ADS)
Boguta, Patrycja; Sokolowska, Zofia
2013-04-01
Humic acids have limited sorption capacity and big dose of metal or other mineral component which can be sorbed on humic acids, can cause saturation of negative, surface charge of humic acids leading to destabilization of dissolved humic acids compounds. Destabilisation can be observed as coagulation and floculation proces of humic acids. However there are a lot of mechanisms which causing precipitation of humic acids. Thereby, in order to full description of coagulation process, different methods should be applied. Ordinarily, humic acids coagulation is studied by measurement of absorbance, transmittance or carbon loss in solution. Meanwhile, very significant information is also variation of metal content in soil solution and information whether metal goes to precipitate together with humic acids or stays in dissolved form in solution. So, that, from one side, processes of stronger accumulation of metal can lead to soil degradation and micronutrient deficiency for plants. However, there is also possibility to stay metal in solution in toxic and bioavailable form for plants. Main aim of this paper was to study coagulation process of different humic acids extracted from mucking peats under copper ions influence at adjusted pH to 5. In order to this, four peaty-muck soils were taken from selected places in east part of Poland (meadows and river valleys). These soils differed by humification degree, secondary transformation, density and pH. At next step, humic acids were extracted from soils using sodium hydroxide (NaOH) extractant. After exact purification by washing with HF-HCl mixture and water, humic acids were liofilized. Solutions of humic acids were prepared at concentration 40 mg/dm3 with addition of different amount of copper ions to obtain final concentration of Cu(II) ranged from 0-40mg/dm3. After 24 hours solutions were investigated using measurements of absorbance at 470nm (UV-VIS spectrometer Jasco V-530), measurements of organic carbon in solution (carbon analyzer: Multi NC2000, Analityk Jena) and measurements of copper content in solution (atomic absorption spectrometer: Contraa300, Analityk Jena). On the base of obtained results initial and end point of coagulation was determined for each of humic acids. Results showed that coagulation points differed for different humic acids and it was probably depended on sorption possibilities. Coagulation points determined from UV-VIS measurements overlapped with points from carbon measurement. Loss of carbon during coagulation was almost total but loss of copper in solution during humic acid coagulation was much smaller and did not cover exactly points of carbon precipitation. So that, coagulation of humic acids under copper influence could resulted from both bonding of metal by functional groups and creating complexes and also from increasing ionic strength. Important is that organic carbon went to insoluble form and copper stayed in movable compounds. Such studies and conclusions coming from them, can be very important from ecological side. *This work was partly supported by the National Science Centre in Poland, grant No. UMO-2011/03/N/NZ9/04239.
Removal and Transformation of Estrogens During the Coagulation Process
Estrogenic compounds have been shown to be present in surface waters, leading to concerns over the possible presence of endocrine disrupting compounds in finished drinking waters. Bench-scale studies (jar tests) simulating coagulation were conducted to evaluate the ability of tw...
Leite Júnior, Bruno Ricardo de Castro; Tribst, Alline Artigiani Lima; Cristianini, Marcelo
2015-01-01
This study investigated the effect of high pressure homogenization (HPH) (up to 190 MPa) on porcine pepsin (proteolytic and milk-clotting activities), and the consequences of using the processed enzyme in milk coagulation and gel formation (rheological profile, proteolysis, syneresis, and microstructure). Although the proteolytic activity (PA) was not altered immediately after the HPH process, it reduced during enzyme storage, with a 5% decrease after 60 days of storage for samples obtained with the enzyme processed at 50, 100 and 150 MPa. HPH increased the milk-clotting activity (MCA) of the enzyme processed at 150 MPa, being 15% higher than the MCA of non-processed samples after 60 days of storage. The enzyme processed at 150 MPa produced faster aggregation and a more consistent milk gel (G’ value 92% higher after 90 minutes) when compared with the non-processed enzyme. In addition, the gels produced with the enzyme processed at 150 MPa showed greater syneresis after 40 minutes of coagulation (forming a more compact protein network) and lower porosity (evidenced by confocal microscopy). These effects on the milk gel can be associated with the increment in MCA and reduction in PA caused by the effects of HPH on pepsin during storage. According to the results, HPH stands out as a process capable of changing the proteolytic characteristics of porcine pepsin, with improvements on the milk coagulation step and gel characteristics. Therefore, the porcine pepsin submitted to HPH process can be a suitable alternative for the production of cheese. PMID:25938823
Degradation of black liquor from bioethanol process using coagulation and Fenton-like methods
NASA Astrophysics Data System (ADS)
Muryanto, Muryanto; Sari, Ajeng Arum; Abimanyu, Haznan
2017-01-01
Black liquor is one of the main by-products of the pretreatment process in bioethanol production from oil palm empty fruit bunches. Black liquor wastewater releases black coloured effluent with high chemical oxygen demand (COD) and low dissolved oxygen (DO). It had a distinctive dark coloration, high alkalinity (pH=13), high organic content (COD > 50,000 ppm) and a high solid content (TSS > 5,000 ppm). Lignin destruction can be done by using high oxidation from OH radical system such as advanced oxidation processes (AOPs). Thereafter, the high concentration of COD, color, and TSS can be removed. The general aim of the present investigation was to determine degradation of black liquor wastewater by using a combined coagulation and Fenton-like methods. In this research, we use Poly Aluminum Chloride (PAC) as a coagulant and FeCl3.6H2O and H2O2 for Fenton-like's reagent. The process was conducted in jar test at 200 rpm for 30 minutes and after that slowly mixed for 2 hours and left for sedimentation 24 hours. 50 ml black liquor was added with variation dose of 1-5% PAC, and 10 % Fenton-like reagent. Hydroxyl radical was generated by the Fenton-like's reagent (ratio FeCl3.6H2O : H2O2 was varied). The highest decolorization of black liquor 70 % was obtained under 5% PAC coagulant. The pH of the wastewater was reduced from 13.00 to 8.07 after the addition of the coagulant. The decolorization of original black liquor was approximately 58% through the Fenton-like process. The combination of PAC and Fenton-like reagent has able to enhance the decolorization of black liquor up to 97%.
Kim, Han-Lae; Cho, Jong-Bok; Park, Yong-Jin; Cho, Il-Hyoung
2016-07-02
A pilot-scale study was conducted using the electrocoagulation-electroflotation (EC-EF) process to treat textile dyeing raw wastewater to evaluate treatment performance. The effects of some key factors, such as current density, hydraulic retention time (HRT), and removal of conductivity, total suspended solids (TSS), chemical oxygen demand (COD), and color were investigated. The operating variables were current density of 0-300 A m(-2), HRT of 0-30 min, and a coagulant (anionic polyacrylamide (A-PAM)) dosage of 0-30 mg L(-1). Daphnia magna was used to test acute toxicity in raw and treated wastewater. Under the operating conditions without added coagulant, maxima of 51%, 88%, 84%, and 99% of conductivity, TSS, COD, and color were removed, respectively, with a HRT of 30 min. The coagulant enhanced removal of all wastewater parameters. Removal maxima of 59%, 92%, 94%, and 98% for conductivity, TSS, COD, and color were observed, respectively, with an optimal dosage of 30 mg L(-1) and a shortened HRT of 20 min. The 48 h-LC50 D. magna test showed that the raw wastewater was highly toxic. However, the EC-EF process decreased toxicity of the treated samples significantly, and >70% toxicity reduction was achieved by the EC-EF process with the addition of 15-30 mg L(-1) coagulant, HRT of 20 min, and current density of 150-300 A m(-2). The pilot scale test (0.3 m(3 )h(-1)) shows that the EC-EF process with added coagulant effectively treated textile dyeing wastewater.
Study on Coagulant Dosing Control System of Micro Vortex Water Treatment
NASA Astrophysics Data System (ADS)
Fengping, Hu; Qi, Fan; Wenjie, Hu; Xizhen, He; Hongling, Dai
2018-03-01
In view of the characteristics of nonlinearity, large time delay and multi disturbance in the process of coagulant dosing in water treatment, it is difficult to control the dosage of coagulant. According to the four indexes of raw water quality parameters (raw water flow, turbidity, pH value) and turbidity of sedimentation tank, the micro vortex coagulation dosing control model is constructed based on BP neural network and GA. The forecast results of BP neural network model are ideal, and after the optimization of GA, the prediction accuracy of the model is partly improved. The prediction error of the optimized network is ±0.5 mg/L, and has a better performance than non-optimized network.
A Pontential Agriculture Waste Material as Coagulant Aid: Cassava Peel
NASA Astrophysics Data System (ADS)
Othman, N.; Abd-Rahim, N.-S.; Tuan-Besar, S.-N.-F.; Mohd-Asharuddin, S.; Kumar, V.
2018-02-01
All A large amount of cassava peel waste is generated annually by small and medium scale industries. This has led to a new policy of complete utilization of raw materials so that there will be little or no residue left that could pose pollution problems. Conversion of these by-products into a material that poses an ability to remove toxic pollutant would increase the market value and ultimately benefits the producers. This study investigated the characteristics of cassava peel as a coagulant aid material and optimization process using the cassava peel was explored through coagulation and flocculation. This research had highlighted that the Cassava peels contain sugars in the form of polysaccharides such as starch and holocellulose. The FTIR results revealed that amino acids containing abundant of carboxyl, hydroxyl and amino groups which has significant capabilities in removing pollutants. Whereas analysis by XRF spectrometry indicated that the CP samples contain Fe2O3 and Al2O3 which might contribute to its coagulation ability. The optimum condition allowed Cassava peel and alum removed high turbidity up to 90. This natural coagulant from cassava peel is found to be an alternative coagulant aid to reduce the usage of chemical coagulants
Takahashi, Hidekazu; Haraguchi, Naotsugu; Nishimura, Junichi; Hata, Taishi; Matsuda, Chu; Yamamoto, Hirofumi; Mizushima, Tsunekazu; Mori, Masaki; Doki, Yuichiro; Nakajima, Kiyokazu
2018-06-01
Modern electrosurgical tools have a specific coagulation mode called "soft coagulation". However, soft coagulation has not been widely accepted for surgical operations. To optimize the soft coagulation environment, we developed a novel suction device integrated with an electrosurgical probe, called the "Suction ball coagulator" (SBC). In this study, we aimed to optimize the SBC design with a prototyping process involving a bench test and preclinical study; then, we aimed to demonstrate the feasibility, safety, and potential effectiveness of the SBC for laparoscopic surgery in clinical settings. SBC prototyping was performed with a bench test. Device optimization was performed in a preclinical study with a domestic swine bleeding model. Then, SBC was tested in a clinical setting during 17 clinical laparoscopic colorectal surgeries. In the bench tests, two tip hole sizes and patterns showed a good suction capacity. The preclinical study indicated the best tip shape for accuracy. In clinical use, no device-related adverse event was observed. Moreover, the SBC was feasible for prompt hemostasis and blunt dissections. In addition, SBC could evacuate vapors generated by tissue ablation using electroprobe during laparoscopic surgery. We successfully developed a novel, integrated suction/coagulation probe for hemostasis and commercialized it.
White, Hayden; Bird, Robert; Sosnowski, Kellie; Jones, Mark
2016-06-01
Thrombosis is a complication of many chronic illnesses. Chronic obstructive pulmonary disease (COPD) and diabetes mellitus are common medical conditions frequently associated with a hypercoagulable state. Acidaemia has been shown to reduce coagulation. COPD and diabetes mellitus during acute deterioration can present with a severe acidaemia. The impact of this acidaemia on coagulation is poorly studied. Patients presenting with a diagnosis of diabetic ketoacidosis or type II respiratory failure from COPD and a pH of less than 7.2 were included in our study. A coagulation screen and a thromboelastograph (TEG) were performed on admission and 24 hours later. The mean pH on admission was 7.07 and mean base excess was -16.3. The activated partial thromboplastin time was associated with pH change but remained within the normal range (26-41 s). All other coagulation and TEG parameters failed to show evidence of association (p>0.05). In the two models of non-haemorrhagic acidosis investigated, coagulation was not altered by the changes in pH. More work is needed to understand the complex relationship between factors affecting coagulation in individual disease processes. © 2016 Royal College of Physicians.
Nowak, Sascha; Winter, Martin
2017-03-06
Quantitative electrolyte extraction from lithium ion batteries (LIB) is of great interest for recycling processes. Following the generally valid EU legal guidelines for the recycling of batteries, 50 wt % of a LIB cell has to be recovered, which cannot be achieved without the electrolyte; hence, the electrolyte represents a target component for the recycling of LIBs. Additionally, fluoride or fluorinated compounds, as inevitably present in LIB electrolytes, can hamper or even damage recycling processes in industry and have to be removed from the solid LIB parts, as well. Finally, extraction is a necessary tool for LIB electrolyte aging analysis as well as for post-mortem investigations in general, because a qualitative overview can already be achieved after a few minutes of extraction for well-aged, apparently "dry" LIB cells, where the electrolyte is deeply penetrated or even gellified in the solid battery materials.
[Microcystin safety study during Cyanobacteria removal by pressure enhanced coagulation process].
Jiang, Xin-Yue; Luan, Qing; Cong, Hai-Bing; Xu, Si-Tao; Liu, Yu-Jiao; Zhu, Xue-Yuan
2014-11-01
Pressure enhanced coagulation and sedimentation technique is an effective way for blue algae treatment. It is not clear whether Cyanobacteria balloon rupture will cause Cyanobacteria cells rupture, resulting in high intracellular concentrations of microcystin LR leak into the water, affecting drinking water safety. Therefore, in this study experimental comparative study of pressure and pre-oxidation of water containing Cyanobacteria was carried out to examine the microcystin LR concentration changes and Cyanobacteria removal efficiency. The results showed that microcystin concentration increase was not significant by the pre-treatment with Cyanobacteria water pressure, while the pre-oxidation process caused a significant increase in the concentration of microcystin. After 0.5-0.8 MPa pressure coagulation and sedimentation, removal of Cyanobacteria basically was over 90%, up to 93.5%, while the removal rate by pre-oxidation was low and unstable. Effluent turbidity is also significantly better in the pre-pressure method than the pre-oxidation. The results indicated that pressure enhanced coagulation is a safe and reliable method for Cyanobacteria removal.
Utilization of Drinking Water Treatment Slurry to Produce Aluminum Sulfate Coagulant.
Fouad, Mahmoud M; Razek, Taha M A; Elgendy, Ahmed S
2017-02-01
In Egypt, water treatment consumes about 365 000 tons of aluminum sulfate and produces more than 100 million tons of sludge per year. The common disposal system of sludge in Egypt is to discharge it into natural waterways. Toxicity of aluminum, environmental regulations and costs of chemicals used in water treatment and sludge treatment processes led to an evaluation of coagulant recovery and subsequent reuse. The present work aimed at aluminum recovery from sludge of El-Shiekh Zayd water treatment plant (WTP) to produce aluminum sulfate coagulant. Sludge was characterized and the effect of five variables was tested and the process efficiency was evaluated at different operating conditions. Maximum recovery is 94.2% at acid concentration 1.5 N, sludge weight 5 g, mixing speed 60 rpm, temperature 60 °C and leaching time 40 min. Then optimum conditions were applied to get maximum recovery for aluminum sulfate and compared to commercial coagulant on raw water of El-Shiekh Zayd (WTP).
Mahdavi, Mokhtar; Ebrahimi, Afshin; Azarpira, Hossein; Tashauoei, Hamid Reza; Mahvi, Amir Hossein
2017-12-01
During operation of most water treatment plants, spent filter backwash water (SFBW) is generated, which accounts about 2-10% of the total plant production. By increasing world population and water shortage in many countries, SFBW can be used as a permanent water source until the water treatment plant is working. This data article reports the practical method being used for water reuse from SFBW through different method including pre-sedimentation, coagulation and flocculation, second clarification, ultra filtration (UF) and returned settled SFBW to the beginning of water treatment plant (WTP). Also, two coagulants of polyaluminum ferric chloride (PAFCl) and ferric chloride (FeCl 3 ) were investigated with respect to their performance on treated SFBW quality. Samples were collected from Isfahan's WTP in Iran during spring and summer season. The acquired data indicated that drinkable water can be produced form SFBW by applying hybrid coagulation-UF process (especially when PAFCl used as coagulant).
Multilayered composite proton exchange membrane and a process for manufacturing the same
Santurri, Pasco R; Duvall, James H; Katona, Denise M; Mausar, Joseph T; Decker, Berryinne
2015-05-05
A multilayered membrane for use with fuel cells and related applications. The multilayered membrane includes a carrier film, at least one layer of an undoped conductive polymer electrolyte material applied onto the carrier film, and at least one layer of a conductive polymer electrolyte material applied onto the adjacent layer of polymer electrolyte material. Each layer of conductive polymer electrolyte material is doped with a plurality of nanoparticles. Each layer of undoped electrolyte material and doped electrolyte material may be applied in an alternating configuration, or alternatively, adjacent layers of doped conductive polymer electrolyte material is employed. The process for producing a multilayered composite membrane includes providing a carrier substrate and solution casting a layer of undoped conductive polymer electrolyte material and a layer of conductive polymer electrolyte material doped with nanoparticles in an alternating arrangement or in an arrangement where doped layers are adjacent to one another.
Pinheiro, C T; Ascensão, V R; Reis, M S; Quina, M J; Gando-Ferreira, L M
2017-12-01
Coagulation phenomena can occur in certain types of waste lubricant oils (WLO) during regeneration processes involving alkaline treatments, causing plant shutdowns. In this context, this study addresses the nature of the compounds responsible for the coagulation phenomena after the alkaline treatment. For such, an empirical test was developed to assess the coagulation behaviour of WLO, consisting in the addition of KOH to the WLO followed by heating under stirring conditions. This test was performed on 133 samples and four coagulation classes were identified: A; B1; B2 and C. Moreover, a physicochemical characterization of WLO was carried out regarding viscosity at 40°C, saponification number (SN), total acid number (TAN), surface tension, water content, elemental analysis and functional groups (FTIR). 56 samples of fresh lubricant oils for different applications were also characterized and their properties assessed and compared. Multivariate methods were applied to WLO to discriminate among coagulation classes based on FTIR spectra. It was found that coagulation classes A and B1 exhibit statistically similar patterns for all properties determined. Spectral discriminating analysis did not reveal discriminant peaks for class B1 samples, and the presence of specific additives was pointed as the possible factor underlying the increase in viscosity in this oils. Class B2 presents the absence of additives and oxidation products as differentiating features. In addition, B2 samples showed lower TAN SN, and lower concentration of some elements. Lubricants from gear or hydraulic applications can give rise to this class of WLO. Oils of Class C are mainly composed by synthetic ester type base oils, which hamper regeneration processes using alkaline pretreatments. In future studies, WLO type A and B1 can be classified as a single class. The coagulation phenomena classification becomes A - negative, B - precipitate formation and C - positive. Copyright © 2017 Elsevier B.V. All rights reserved.
Sparks, Rachel; Salskov, Alex H; Chang, Anita S; Wentworth, Kelly L; Gupta, Pritha P; Staiger, Thomas O; Anawalt, Bradley D
2015-01-01
Complete documentation of patient comorbidities in the medical record is important for clinical care, hospital reimbursement, and quality performance measures. We designed a pocket card reminder and brief educational intervention aimed at hospitalists with the goal of improving documentation of 6 common comorbidities present on admission: coagulation abnormalities, metastatic cancer, anemia, fluid and electrolyte abnormalities, malnutrition, and obesity. Two internal medicine inpatient teams led by 10 hospitalist physicians at an academic medical center received the educational intervention and pocket card reminder (n = 520 admissions). Two internal medicine teams led by nonhospitalist physicians served as a control group (n = 590 admissions). Levels of documentation of 6 common comorbidities, expected length of stay, and expected mortality were measured at baseline and during the 9-month study period. The intervention was associated with increased documentation of anemia, fluid and electrolyte abnormalities, malnutrition, and obesity in the intervention group, both compared to baseline and compared to the control group during the study period. The expected length of stay increased in the intervention group during the study period. A simple educational intervention and pocket card reminder were associated with improved documentation and hospital quality measures at an academic medical center.
Mortadi, A; Chahid, El G; Nasrellah, H; Cherkaoui, O; El Moznine, R
2017-09-28
The analysis of the complex permittivity, electrical complex modulus and the hopping conductivity have been employed in order to investigate the impacts of calcium oxide during sludge treatment in textile such as coagulation process. In this context, impedance measurement was performed on five samples, including raw sludge and four compositions containing different amounts of calcium oxide: 2%, 3%, 4% and 5% (w/w). The dielectric spectra of each composition were described by the summation of a power law and a Cole-Cole relaxation model. The relaxation time and the magnitude of the dielectric relaxation obtained from the analysis of dielectric properties showed an increase up to 3% of these parameters with the addition of calcium oxide. Above this critical value, both parameters showed a very small change, suggesting that the aggregation became more stable. In addition, the evolution of the hopping conductivity reached a minimum value at this critical amount (3%). This evolution was well described by a double power law, which allowed us to estimate the optimal amount of the calcium oxide to achieve coagulation process. The analysis of the dielectric properties was found useful in monitoring aggregation processes that occur during the coagulation mechanism in textile sludge.
Anticoagulation by factor Xa inhibitors.
Orfeo, T; Butenas, S; Brummel-Ziedins, K E; Gissel, M; Mann, K G
2010-08-01
Therapeutic agents that regulate blood coagulation are critical to the management of thrombotic disorders, with the selective targeting of factor (F) Xa emerging as a promising approach. To assess anticoagulant strategies targeting FXa. A deterministic computational model of tissue factor (Tf)-initiated thrombin generation and two empirical experimental systems (a synthetic coagulation proteome reconstruction using purified proteins and a whole blood model) were used to evaluate clinically relevant examples of the two available types of FXa-directed anticoagulants [an antithrombin (AT)-dependent agent, fondaparinux, and an AT-independent inhibitor, Rivaroxaban] in experimental regimens relevant to long-term (suppression of new Tf-initiated events) and acute (suppression of ongoing coagulation processes) clinical applications. Computational representations of each anticoagulant's efficacy in suppressing thrombin generation over a range of anticoagulant concentrations in both anticoagulation regimens were validated by results from corresponding empirical reconstructions and were consistent with those recommended for long-term and acute clinical applications, respectively. All three model systems suggested that Rivaroxaban would prove more effective in the suppression of an ongoing coagulation process than fondaparinux, reflecting its much higher reactivity toward the prothrombinase complex. The success of fondaparinux in acute settings in vivo is not explained solely by its properties as an FXa inhibitor. We have reported that FIXa contributes to the long-term capacity of clot-associated catalysts to restart a coagulation process, suggesting that the enhanced anti-FIXa activity of fondaparinux-AT may be critical to its success in acute settings in vivo. © 2010 International Society on Thrombosis and Haemostasis.
NASA Astrophysics Data System (ADS)
Tsai, I.-Chun; Chen, Jen-Ping; Lin, Yi-Chiu; Chung-Kuang Chou, Charles; Chen, Wei-Nai
2015-05-01
A statistical-numerical aerosol parameterization was incorporated into the Community Multiscale Air Quality modeling system to study the coagulation mixing process focusing on a dust storm event that occurred over East Asia. Simulation results show that the coagulation mixing process tends to decrease aerosol mass, surface area, and number concentrations over the dust source areas. Over the downwind oceanic areas, aerosol concentrations generally increased due to enhanced sedimentation as particles became larger upon coagulation. The mixture process can reduce the overall single-scattering albedo by up to 10% as a result of enhanced core with shell absorption by dust and reduction in the number of scattering particles. The enhanced dry deposition speed also altered the vertical distribution. In addition, the ability of aerosol particles to serve as cloud condensation nuclei (CCN) increased from around 107 m-3 to above 109 m-3 over downwind areas because a large amount of mineral dust particles became effective CCN with solute coating, except over the highly polluted areas where multiple collections of hygroscopic particles by dust in effect reduced CCN number. This CCN effect is much stronger for coagulation mixing than by the uptake of sulfuric acid gas on dust, although the nitric acid gas uptake was not investigated. The ability of dust particles to serve as ice nuclei may decrease or increase at low or high subzero temperatures, respectively, due to the switching from deposition nucleation to immersion freezing or haze freezing.
Park, Junwon; Yamashita, Naoyuki; Tanaka, Hiroaki
2018-04-01
We investigated the effects of the addition of two coagulants-polyaluminium chloride (PACl) and chitosan-into the membrane bioreactor (MBR) process on membrane fouling and the removal of pharmaceuticals and personal care products (PPCPs). Their addition at optimized dosages improved the permeability of the membrane by reducing the concentration of soluble microbial products in mixed liquor, the content of inorganic elements, and irreversible fouling of the membrane surface. During long-term operation, the addition of PACl increased removal efficiencies of tetracycline, mefenamic acid, atenolol, furosemide, ketoprofen, and diclofenac by 17-23%. The comparative evaluation using mass balance calculations between coagulation-MBR (with PACl addition) and control-MBR (without PACl addition) showed that enhanced biodegradability played a key role in improving removal efficiencies of some PPCPs in coagulation-MBR. Coagulation-MBR also had higher oxygen uptake rates and specific nitrification rates of microorganisms. Overall, our findings suggest that the combination of MBR with coagulation reduced membrane fouling, lengthening operation period of the membrane, and improved the removal of some PPCPs as a result of enhanced biodegradability. Copyright © 2018 Elsevier Ltd. All rights reserved.
Jia, Lijuan; Shen, Zhemin; Su, Pingru
2016-05-01
Fenton oxidation is a promising water treatment method to degrade organic pollutants. In this study, 30 different organic compounds were selected and their reaction rate constants (k) were determined for the Fenton oxidation process. Gaussian09 and Material Studio software sets were used to carry out calculations and obtain values of 10 different molecular descriptors for each studied compound. Ferric-oxyhydroxide coagulation experiments were conducted to determine the coagulation percentage. Based upon the adsorption capacity, all of the investigated organic compounds were divided into two groups (Group A and Group B). The percentage adsorption of organic compounds in Group A was less than 15% (wt./wt.) and that in the Group B was higher than 15% (wt./wt.). For Group A, removal of the compounds by oxidation was the dominant process while for Group B, removal by both oxidation and coagulation (as a synergistic process) took place. Results showed that the relationship between the rate constants (k values) and the molecular descriptors of Group A was more pronounced than for Group B compounds. For the oxidation-dominated process, EHOMO and Fukui indices (f(0)x, f(-)x, f(+)x) were the most significant factors. The influence of bond order was more significant for the synergistic process of oxidation and coagulation than for the oxidation-dominated process. The influences of all other molecular descriptors on the synergistic process were weaker than on the oxidation-dominated process. Copyright © 2015. Published by Elsevier B.V.
Treatment of wastewater batik by electrochemical coagulation using aluminium (Al) electrodes
NASA Astrophysics Data System (ADS)
Riyanto; Puspitasari, Eny
2018-01-01
Treatmentof wastewater batik by electrocoagulation method using aluminium (Al) electrodes has been done. Electrocoagulation method was chosen for treatment of wastewater batik because it is cheap, easy and efficient waste degradation. This research was conducted using aluminium (Al) electrodes and sodium chloride as an electrolyte solution. The purity of aluminium electrode was analysis using Scanning Electron Microscopy-Energy Dispersive X-ray (SEM-EDX). Electrochemical coagulation has been done using wastewater batik volume 50 mL with variation of time (10, 30, 50, 70, and 90 minutes), variation of voltage (5, 7, 9, 10, and 11 V), and variation of salt addition (0.5; 0.75; 1.00; and 1.25 g). Batik wastewater was analyzed before and after electrocoagulation by Spectrophotometer UV-Vis and the content of Pb was analyzed by Atomic Absorption Spectrophotometer (AAS). The research results show that optimum conditions electrolysis time, voltage and sodium chloride was 90 minutes, 10 V and 1.25 g, respectively. The results of this study showed the longer the electrolysis time, the higher the voltage, and the increasing number of salt added, then the batik waste decreased absorbance, alteration of color from black to clear yellow. The content of Pb in batik waste has decreased from 0.5844 mg/L to 0.1630 mg/L.
NASA Astrophysics Data System (ADS)
Simchen, F.; Rymer, L.-M.; Sieber, M.; Lampke, T.
2017-03-01
Magnesium and its alloys are increasingly in use as lightweight construction materials. However, their inappropriate corrosion and wear resistance often prevent their direct practical use. The plasma electrolytic oxidation (PEO) is a promising, environmentally friendly method to improve the surface characteristics of magnesium materials by the formation of oxide coatings. These PEO layers contain components of the applied electrolyte and can be shifted in their composition by increasing the concentration of the electrolyte constituents. Therefore, in contrast to the use of conventional low concentrated electrolytes, the process results in more stable protective coatings, in which electrolyte species are the dominating constitutes. In the present work, the influence of the composition of highly concentrated alkaline silicate electrolytes with additives of phosphate and glycerol on the quality of PEO layers on the magnesium alloy AZ31 was examined. The effect of ultrasound coupled into the electrolyte bath was also considered. The process was monitored by recording the electrical process variables with a transient recorder and by observation of the discharge phenomena on the sample surface with a camera. The study was conducted on the basis of a design of experiments. The effects of the process parameter variation are considered with regard to the coatings thickness, hardness and corrosion resistance. Information about the statistical significance of the effects of the parameters on the considered properties is obtained by an analysis of variance (ANOVA).
Arimi, Milton M; Zhang, Yongjun; Namango, Saul S; Geißen, Sven-Uwe
2016-03-01
Anaerobic digestion is used to treat effluents with a lot of organics, such as molasses distillery wastewater (MDW) which is the effluent of bioethanol production from molasses. The raw MDW requires a lot of dilution water before biodigestion, while the digested MDW has high level of recalcitrants which are problematic for its discharge. This study investigated ferric coagulation, Fenton, Fenton-like (with ferric ions as catalyst) processes and their combinations on the biodegradability of digested MDW. The Fenton and Fenton-like processes after coagulation increased the MDW biodegradability defined by (BOD5/COD) from 0.07 to (0.4-0.6) and saved 50% of H2O2 consumed in the classic Fenton process. The effluent from coagulation coupled to a Fenton-like process was used as dilution water for the raw MDW before the anaerobic digestion. The process was stable with volumetric loading of approx. 2.7 g COD/L/d. It resulted in increased overall biogas recovery and significantly decreased the demand for the dilution water. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zhou, Zhiwei; Yang, Yanling; Li, Xing; Gao, Wei; Liang, Heng; Li, Guibai
2012-01-01
Drinking water treatment sludge, characterized as accumulated suspended solids and organic and inorganic matter, is produced in large quantities during the coagulation process. The proper disposal, regeneration or reuse of sludge is, therefore, a significant environmental issue. Reused sludge at low temperatures is an alternative method to enhance traditional coagulation efficiency. In the present study, the recycling mass of mixed sludge and properties of raw water (such as pH and turbidity) were systematically investigated to optimize coagulation efficiency. We determined that the appropriate dosage of mixed sludge was 60 mL/L, effective initial turbidity ranges were below 45.0 NTU, and optimal pH for DOMs and turbidity removal was 6.5-7.0 and 8.0, respectively. Furthermore, by comparing the flocs characteristics with and without recycling sludge, we found that floc structures with sludge were more irregular with average size growth to 64.7 microm from 48.1 microm. Recycling sludge was a feasible and successful method for enhancing pollutants removal, and the more irregular flocs structure after recycling might be caused by breakage of reused flocs and incorporation of powdered activated carbon into larger flocs structure. Applied during the coagulation process, recycling sludge could be significant for the treatment of low temperature and micro-polluted source water.
COSMIC DUST AGGREGATION WITH STOCHASTIC CHARGING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matthews, Lorin S.; Hyde, Truell W.; Shotorban, Babak, E-mail: Lorin_Matthews@baylor.edu
2013-10-20
The coagulation of cosmic dust grains is a fundamental process which takes place in astrophysical environments, such as presolar nebulae and circumstellar and protoplanetary disks. Cosmic dust grains can become charged through interaction with their plasma environment or other processes, and the resultant electrostatic force between dust grains can strongly affect their coagulation rate. Since ions and electrons are collected on the surface of the dust grain at random time intervals, the electrical charge of a dust grain experiences stochastic fluctuations. In this study, a set of stochastic differential equations is developed to model these fluctuations over the surface ofmore » an irregularly shaped aggregate. Then, employing the data produced, the influence of the charge fluctuations on the coagulation process and the physical characteristics of the aggregates formed is examined. It is shown that dust with small charges (due to the small size of the dust grains or a tenuous plasma environment) is affected most strongly.« less
CONTROL OF ORGANIC DRINKING WATER QUALITY BY PRECIPITATIVE PROCESSES
Plant and bench studies were conducted on a highly colored surface water using Alum and Polyvalent Aluminum Chloride (PAC1) coagulation to minimize THMPF. Optimum coagulation pH and dose were identified by season for Alum and PAC1 for color, DOC, THMPF and TOXFP removal. Aluminum...
THE EFFECT OF FLUORIDE ON CONVENTIONAL WATER TREATMENT USING ALUMINUM SULFATE
Based on the Information Collection Rule survey results of 600 large utilities, approximately 50% of them fluoridate their water and of those, 15-20% do so at the location of coagulant addition. In this case, the effect of fluoride on the coagulation process, floc properties, coa...
García-Morales, M A; Roa-Morales, G; Barrera-Díaz, C; Balderas-Hernández, P
2012-01-01
In this research, we studied the treatment of wastewater from the soft drink process using oxidation with ozone. A scheme composed of sequential ozonation-peroxide, ozonation-coagulation and coagulation-ozonation treatments to reduce the organic matter from the soft drink process was also used. The samples were taken from the conventional activated sludge treatment of the soft drink process, and the experiments using chemical oxidation with ozone were performed in a laboratory using a reactor through a porous plate glass diffuser with air as a feedstock for the generation of ozone. Once the sample was ozonated, the treatments were evaluated by considering the contact time, leading to greater efficiency in removing colour, turbidity and chemical oxygen demand (COD). The effect of ozonation and coagulant coupled with treatment efficiency was assessed under optimal conditions, and substantial colour and turbidity removal were found (90.52% and 93.33%, respectively). This was accompanied by a 16.78% reduction in COD (initial COD was 3410 mg/L). The absorbance spectra of the oxidised products were compared using UV-VIS spectroscopy to indicate the level of oxidation of the wastewater. We also determined the kinetics of decolouration and the removal of turbidity with the best treatment. The same treatment was applied to the sample taken from the final effluent of the activated sludge system, and a COD removal efficiency of 100% during the first minute of the reaction with ozone was achieved. As a general conclusion, we believe that the coagulant polyaluminum chloride - ozone (PAC- ozone) treatment of wastewater from the manufacturing of soft drinks is the most efficient for removing turbidity and colour and represents an advantageous option to remove these contaminants because their removal was performed in minutes compared to the duration of traditional physical, chemical and biological processes that require hours or days.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abood, Alkhafaji R.; Thi Qar University, Nasiriyah; Bao, Jianguo, E-mail: bjianguo888@126.com
2014-02-15
Highlights: • A novel method of stripping (agitation) was investigated for NH{sub 3}-N removal. • PFS coagulation followed agitation process enhanced the leachate biodegradation. • Nitrification–denitrification achieved by changing operation process in SBR treatment. • A dual filter of carbon-sand is suitable as a polishing treatment of leachate. • Combined treatment success for the complete treatment of non-biodegradable leachate. - Abstract: This study describes the complete treatment of non-biodegradable landfill leachate by combined treatment processes. The processes consist of agitation as a novel stripping method used to overcome the ammonia toxicity regarding aerobic microorganisms. The NH{sub 3}-N removal ratio wasmore » 93.9% obtained at pH 11.5 and a gradient velocity (G) 150 s{sup −1} within a five-hour agitation time. By poly ferric sulphate (PFS) coagulation followed the agitation process; chemical oxygen demand (COD) and biological oxygen demand (BOD{sub 5}) were removed at 70.6% and 49.4%, respectively at an optimum dose of 1200 mg L{sup −1} at pH 5.0. The biodegradable ratio BOD{sub 5}/COD was improved from 0.18 to 0.31 during pretreatment step by agitation and PFS coagulation. Thereafter, the effluent was diluted with sewage at a different ratio before it was subjected to sequencing batch reactor (SBR) treatment. Up to 93.3% BOD{sub 5}, 95.5% COD and 98.1% NH{sub 3}-N removal were achieved by SBR operated under anoxic–aerobic–anoxic conditions. The filtration process was carried out using sand and carbon as a dual filter media as polishing process. The final effluent concentration of COD, BOD{sub 5}, suspended solid (SS), NH{sub 3}-N and total organic carbon (TOC) were 72.4 mg L{sup −1}, 22.8 mg L{sup −1}, 24.2 mg L{sup −1}, 18.4 mg L{sup −1} and 50.8 mg L{sup −1} respectively, which met the discharge standard. The results indicated that a combined process of agitation-coagulation-SBR and filtration effectively eliminated pollutant loading from landfill leachate.« less
Berjano, Enrique J; Burdío, Fernando; Navarro, Ana C; Burdío, José M; Güemes, Antonio; Aldana, Oscar; Ros, Paloma; Sousa, Ramón; Lozano, Ricardo; Tejero, Eloy; de Gregorio, Miguel A
2006-10-01
Current systems for radiofrequency ablation of liver tumors are unable to consistently treat tumors larger than 3 cm in diameter with a single electrode in a single application. One of the strategies for enlarging coagulation zone dimensions is to infuse saline solutions into the tissue through the active electrodes. Nevertheless, the uncontrolled and undirected diffusion of boiling saline into the tissue has been associated with irregular coagulation zones and severe complications, mainly due to reflux of saline along the electrode path. In order to improve the perfusion bipolar ablation method, we hypothesized that the creation of small monopolar coagulation zones adjacent to the bipolar electrodes and previous to the saline infusion would create preferential paths for the saline to concentrate on the targeted coagulation zone. Firstly, we conducted ex vivo experiments in order to characterize the monopolar coagulation zones. We observed that they are practically impermeable to the infused saline. On the basis of this finding, we built theoretical models and conducted computer simulations to assess the feasibility of our hypothesis. Temperature distributions during bipolar ablations with and without previous monopolar coagulation zones were obtained. The results showed that in the case of monopolar coagulation zones the temperature of the tissue took longer to reach 100 degrees C. Since this temperature value is related to rise of impedance, and the time necessary for this process is directly related to the volume of the coagulation zone, our results suggest that monopolar sealing would allow larger coagulation zones to be created. Future experimental studies should confirm this benefit.
[Combined use of active chlorine and coagulants for drinking water purification and disinfection].
Rakhmanin, Iu A; Zholdakova, Z I; Poliakova, E E; Kir'ianova, L F; Miasnikov, I N; Tul'skaia, E A; Artemova, T Z; Ivanova, L V; Dmitrieva, R A; Doskina, T V
2004-01-01
The authors made an experimental study of the efficiency of water purification procedures based on the combined use of active chlorine and coagulants and hygienically evaluated the procedures. The study included the evaluation of water disinfection with various coagulants and active chlorine; the investigation of the processes of production of deleterious organic chlorine compounds; the assessment of the quality of water after its treatment. The coagulants representing aluminum polyoxychloride: RAX-10 (AQUA-AURATE 10) and RAX-18 (AQUA-AURATE 18), and aluminum sulfate, technically pure grade were tested. The treatment of river water with the coagulants RAX-10 and RAX-18, followed by precipitation, filtration, and chlorination under laboratory conditions, was shown to result in water disinfection to the levels complying with the requirements described in SanPiN 2.1.4.1074-01. RAX-18 showed the best disinfecting activity against total and heat-tolerant coliform bacteria, but also to the highly chlorine-resistant microrganisms--the spores of sulfite-reducing Clostridia, phages, and viruses. Since the coagulants have an increased sorptive capacity relative to humus and other organic substances, substitution of primary chlorination for coagulant treatment may induce a reduction in the risk of formation of oncogenically and mutagenically hazardous chlorinated hydrocarbons.
Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju
2015-11-16
Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.
Naceradska, Jana; Pivokonsky, Martin; Pivokonska, Lenka; Baresova, Magdalena; Henderson, Rita K; Zamyadi, Arash; Janda, Vaclav
2017-05-01
The study investigates the effect of permanganate pre-oxidation on the coagulation of peptides/proteins of Microcystis aeruginosa which comprise a major proportion of the organic matter during cyanobacterial bloom decay. Four different permanganate dosages (0.1, 0.2, 0.4 and 0.6 mg KMnO 4 mg -1 DOC) were applied prior to coagulation by ferric sulphate. Moreover, changes in sample characteristics, such as UV 254 , DOC content and molecular weight distribution, after pre-oxidation were monitored. The results showed that permanganate pre-oxidation led to a reduction in coagulant dose, increased organic matter removals by coagulation (by 5-12% depending on permanganate dose), microcystin removal (with reductions of 91-96%) and a shift of the optimum pH range from 4.3 to 6 without to 5.5-7.3 with pre-oxidation. Degradation of organic matter into inorganic carbon and adsorption of organic matter onto hydrous MnO 2 are suggested as the main processes responsible for coagulation improvement. Moreover, permanganate prevented the formation of Fe-peptide/protein complexes that inhibit coagulation at pH about 6.2 without pre-oxidation. The study showed that carefully optimized dosing of permanganate improves cyanobacterial peptide/protein removal, with the benefit of microcystin elimination. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju
2015-11-01
Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.
Apparatus and process for the electrolytic reduction of uranium and plutonium oxides
Poa, David S.; Burris, Leslie; Steunenberg, Robert K.; Tomczuk, Zygmunt
1991-01-01
An apparatus and process for reducing uranium and/or plutonium oxides to produce a solid, high-purity metal. The apparatus is an electrolyte cell consisting of a first container, and a smaller second container within the first container. An electrolyte fills both containers, the level of the electrolyte in the first container being above the top of the second container so that the electrolyte can be circulated between the containers. The anode is positioned in the first container while the cathode is located in the second container. Means are provided for passing an inert gas into the electrolyte near the lower end of the anode to sparge the electrolyte and to remove gases which form on the anode during the reduction operation. Means are also provided for mixing and stirring the electrolyte in the first container to solubilize the metal oxide in the electrolyte and to transport the electrolyte containing dissolved oxide into contact with the cathode in the second container. The cell is operated at a temperature below the melting temperature of the metal product so that the metal forms as a solid on the cathode.
Li, Jiuyi; Zhao, Lei; Qin, Lele; Tian, Xiujun; Wang, Aimin; Zhou, Yanmei; Meng, Liao; Chen, Yong
2016-03-01
Removal of the refractory organic matters in leachate brines generated from nanofiltration unit in two full-scale municipal solid waste landfill leachate treatment plants was investigated by Fenton oxidative-coagulation and ultraviolet photo - Fenton processes in this study. Fenton oxidative-coagulation was performed under the condition of an initial pH of 5.0 and low H2O2/Fe(2+) ratios. After precipitate separation, the remaining organic constituents were further oxidized by photo - Fenton process. For both leachate brines with varying pollution strength, more than 90% COD and TOC reductions were achieved at H2O2/Fe(2+) dosages of 35 mM/8 mM and 90 mM/10 mM, respectively. The effluent COD ranged 120-160 mg/L under the optimal operating conditions, and the biodegradability was increased significantly. Fenton oxidative-coagulation was demonstrated to contribute nearly 70% overall removal of organic matters. In the combined processes, the efficiency of hydrogen peroxide varied from 216 to 228%, which may significantly reduce the operating cost of conventional Fenton method. Six phthalic acid esters and thirteen polycyclic aromatic hydrocarbons were found in leachate brines, and, on the average, around 80% phthalic acid esters and 90% polycyclic aromatic hydrocarbons were removed by the combined treatments. Copyright © 2015 Elsevier Ltd. All rights reserved.
An optical approach for non-invasive blood clot testing
NASA Astrophysics Data System (ADS)
Kalchenko, Vyacheslav; Brill, Alexander; Fine, Ilya; Harmelin, Alon
2007-02-01
Physiological blood coagulation is an essential biological process. Current tests for plasma coagulation (clotting) need to be performed ex vivo and require fresh blood sampling for every test. A recently published work describes a new, noninvasive, in vivo approach to assess blood coagulation status during mechanical occlusion1. For this purpose, we have tested this approach and applied a controlled laser beam to blood micro-vessels of the mouse ear during mechanical occlusion. Standard setup for intravital transillumination videomicroscopy and laser based imaging techniques were used for monitoring the blood clotting process. Temporal mechanical occlusion of blood vessels in the observed area was applied to ensure blood flow cessation. Subsequently, laser irradiation was used to induce vascular micro-injury. Changes in the vessel wall, as well as in the pattern of blood flow, predispose the area to vascular thrombosis, according to the paradigm of Virchow's triad. In our experiments, two elements of Virchow's triad were used to induce the process of clotting in vivo, and to assess it optically. We identified several parameters that can serve as markers of the blood clotting process in vivo. These include changes in light absorption in the area of illumination, as well as changes in the pattern of the red blood cells' micro-movement in the vessels where blood flow is completely arrested. Thus, our results indicate that blood coagulation status can be characterized by non-invasive, in vivo methodologies.
Electrocoagulation efficiency of the tannery effluent treatment using aluminium electrodes.
Espinoza-Quiñones, Fernando R; Fornari, Marilda M T; Módenes, Aparecido N; Palácio, Soraya M; Trigueros, Daniela E G; Borba, Fernando H; Kroumov, Alexander D
2009-01-01
An electro-coagulation laboratory scale system using aluminium plates electrodes was studied for the removal of organic and inorganic pollutants as a by-product from leather finishing industrial process. A fractional factorial 2(3) experimental design was applied in order to obtain optimal values of the system state variables. The electro-coagulation (EC) process efficiency was based on the chemical oxygen demand (COD), turbidity, total suspended solid, total fixed solid, total volatile solid, and chemical element concentration values. Analysis of variance (ANOVA) for final pH, total fixed solid (TFS), turbidity and Ca concentration have confirmed the predicted models by the experimental design within a 95% confidence level. The reactor working conditions close to real effluent pH (7.6) and electrolysis time in the range 30-45 min were enough to achieve the cost effective reduction factors of organic and inorganic pollutants' concentrations. An appreciable improvement in COD removal efficiency was obtained for electro-coagulation treatment. Finally, the technical-economical analysis results have clearly shown that the electro-coagulation method is very promising for industrial application.
Multifrequency acoustics as a probe of mesoscopic blood coagulation dynamics
NASA Astrophysics Data System (ADS)
Ganesan, Adarsh; Rajendran, Gokulnath; Ercole, Ari; Seshia, Ashwin
2016-08-01
Coagulation is a complex enzymatic polymerisation cascade. Disordered coagulation is common in medicine and may be life-threatening yet clinical assays are typically bulky and/or provide an incomplete picture of clot mechanical evolution. We present the adaptation of an in-plane acoustic wave device: quartz crystal microbalance with dissipation at multiple harmonics to determine the time-evolution of mesoscale mechanical properties of clot formation in vitro. This approach is sensitive to changes in surface and bulk clot structure in various models of induced coagulopathy. Furthermore, we are able to show that clot formation at surfaces has different kinetics and mechanical strength to that in the bulk, which may have implications for the design of bioprosthetic materials. The "Multifrequency acoustics" approach thus enables unique capability to portray biological processes concerning blood coagulation.
Mallik, Suman; Prasad, Ramesh; Bhattacharya, Anindita; Sen, Prosenjit
2018-05-10
Natural phosphatidylserine (PS), which contains two chiral centers, enhances blood coagulation. However, the process by which PS enhanced blood coagulation is not completely understood. An efficient and flexible synthetic route has been developed to synthesize all of the possible stereoisomers of PS. In this study, we examined the role of PS chiral centers in modulating the activity of the tissue factor (TF)-factor VIIa coagulation initiation complex. Full length TF was relipidated with phosphatidylcholine, and the synthesized PS isomers were individually used to estimate the procoagulant activity of the TF-FVIIa complex via a FXa generation assay. The results revealed that the initiation complex activity was stereoselective and had increased sensitivity to the configuration of the PS glycerol backbone due to optimal protein-lipid interactions.
Kim, Dong Young; Lim, Younhee; Roy, Basab; Ryu, Young-Gyoon; Lee, Seok-Soo
2014-12-21
Since the early nineties there have been a number of reports on the experimental development of Mg electrolytes based on organo/amide-magnesium chlorides and their transmetalations. However, there are no theoretical papers describing the underlying operating mechanisms of Mg electrolytes, and there is no clear understanding of these mechanisms. We have therefore attempted to clarify the operating mechanisms of Mg electrolytes by studying the characteristics of Mg complexes, solvation, chemical equilibrium, Mg-deposition processes, electrolyte-oxidation processes, and oxidative degradation mechanism of RMgCl-based electrolytes, using ab initio calculations. The formation and solvation energies of Mg complexes highly depend on the characteristics of R groups. Thus, changes in R groups of RMgCl lead to changes in the equilibrium position and the electrochemical reduction and oxidation pathways and energies. We first provide a methodological scheme for calculating Mg reduction potential values in non-aqueous electrolytes and electrochemical windows. We also describe a strategy for designing Mg electrolytes to maximize the electrochemical windows and oxidative stabilities. These results will be useful not only for designing improved Mg electrolytes, but also for developing new electrolytes in the future.
Hibiscus rosa- sinensis leaf extract as coagulant aid in leachate treatment
NASA Astrophysics Data System (ADS)
Awang, Nik Azimatolakma; Aziz, Hamidi Abdul
2012-12-01
Hibiscus rosa- sinensis is a biodegradable material that has remained untested for flocculating properties. The objective of this study is to examine the efficiency of coagulation-flocculation processes for the removal of color, iron (Fe3+), suspended solids, turbidity and ammonia nitrogen(NH3-N), from landfill leachate using 4,000 mg/L alum in conjunction with H. rosa- sinensis leaf extract (HBaqs). Hydroxyl (O-H) and (carboxyl) C=O functional groups along the HBaqs chain help to indulge flocculating efficiency of HBaqs via bridging. The experiments confirm the positive coagulation properties of HBaqs. The Fe3+ removal rate using 4,000 mg/L alum as sole coagulant was approximately 60 %, and increased to 100 % when 4,000 mg/L alum was mixed with 500 mg/L HBaqs. By mixing, 4,000 mg/L alum with 100-500 mg/L HBaqs, 72 % of SS was removed as compared with only 45 % reduction using 4,000 mg/L alum as sole coagulant.
NASA Astrophysics Data System (ADS)
Muryanto, Muryanto; Hanifah, Ummu; Amriani, Feni; Ibadurrahman, Ahmad Faiz; Sari, Ajeng Arum
2017-11-01
High amounts of black liquor are generated from bioethanol production by using oil palm empty fruit bunches. The black liquor is waste from alkaline pretreatment, it contains high amount of an alkaline solution (NaOH). The black liquor wastewater was highly contaminated with organic materials, and quite toxic for aquatic ecosystems if discharged directly into waters. This study aimed to determine ability of Fenton process combined with coagulation to treat black liquor. The addition 5% of polyaluminium chloride (PAC) could decolorized black liquor, degraded lignin, and produced sludge 70.64%, 68.28%, and 2.76 gram, respectively. Decolorization of black liquor was in line with degradation of black liquor because lignin is the main compound in black liquor. SEM images after addition of PAC of 5% indicated fragmentation of structure. Fenton reagent consist of 0.7 M FeSO4+ 3M H2O2 has able to decolorize black liquor, degrade lignin, and produce sludge 51.67% and 25.44%, and 0.44 gram, respectively. It was concluded that black liquor wastewater from bioethanol can be treated by using Fenton process combined with coagulation. However, these methods still need improvement to obtain the higher degradation rate, and coagulation sludge needs further consideration.
Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.
Chen, Da; Song, Shuren; Ma, Jilong; Zhang, Zhen; Wang, Peng; Liu, Weihui; Guo, Qiuquan
2017-05-15
Monitoring blood coagulation is an important issue in the surgeries and the treatment of cardiovascular diseases. In this work, we reported a novel strategy for the blood coagulation monitoring based on a micro-electromechanical film bulk acoustic resonator. The resonator was excited by a lateral electric field and operated under the shear mode with a frequency of 1.9GHz. According to the apparent step-ladder curves of the frequency response to the change of blood viscoelasticity, the coagulation time (prothrombin time) and the coagulation kinetics were measured with the sample consumption of only 1μl. The procoagulant activity of thromboplastin and the anticoagulant effect of heparin on the blood coagulation process were illustrated exemplarily. The measured prothrombin times showed a good linear correlation with R 2 =0.99969 and a consistency with the coefficient of variation less than 5% compared with the commercial coagulometer. The proposed film bulk acoustic sensor, which has the advantages of small size, light weight, low cost, simple operation and little sample consumption, is a promising device for miniaturized, online and automated analytical system for routine diagnostics of hemostatic status and personal health monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.
Gerlach, Trevor J; Bandt, Carsten; Conner, Bobbi; Ball, Ray L
2015-11-01
To establish reference ranges for coagulation parameters in healthy Florida manatees (Trichechus manatus latirostris) and compare results with those for debilitated manatees undergoing treatment at a rehabilitation facility. Prospective study. 29 healthy manatees and 45 debilitated manatees with various diseases. Manatees considered healthy on the basis of results of physical examination, CBC, and serum biochemical analysis underwent coagulation testing including measurement of prothrombin time, partial thromboplastin time, D-dimer concentration, platelet count, and fibrinogen concentration to establish reference ranges. For comparison, a group of manatees undergoing rehabilitation was also tested, and the results were compared. Thromboelastography was also performed on some animals. Values for D-dimer concentration were significantly higher in debilitated versus healthy animals. There was no significant difference for prothrombin time, partial thromboplastin time, platelet count, or fibrinogen concentration between groups. Thromboelastography was performed on 8 healthy animals. Reference ranges were established for various tests of coagulation that may assist clinicians during the initial evaluation and rehabilitation of Florida manatees. Future research to evaluate the effect of specific disease processes on the coagulation cascade is recommended.
NASA Technical Reports Server (NTRS)
Lee, Yunha; Adams, P. J.
2012-01-01
This study develops more computationally efficient versions of the TwO-Moment Aerosol Sectional (TOMAS) microphysics algorithms, collectively called Fast TOMAS. Several methods for speeding up the algorithm were attempted, but only reducing the number of size sections was adopted. Fast TOMAS models, coupled to the GISS GCM II-prime, require a new coagulation algorithm with less restrictive size resolution assumptions but only minor changes in other processes. Fast TOMAS models have been evaluated in a box model against analytical solutions of coagulation and condensation and in a 3-D model against the original TOMAS (TOMAS-30) model. Condensation and coagulation in the Fast TOMAS models agree well with the analytical solution but show slightly more bias than the TOMAS-30 box model. In the 3-D model, errors resulting from decreased size resolution in each process (i.e., emissions, cloud processing wet deposition, microphysics) are quantified in a series of model sensitivity simulations. Errors resulting from lower size resolution in condensation and coagulation, defined as the microphysics error, affect number and mass concentrations by only a few percent. The microphysics error in CN70CN100 (number concentrations of particles larger than 70100 nm diameter), proxies for cloud condensation nuclei, range from 5 to 5 in most regions. The largest errors are associated with decreasing the size resolution in the cloud processing wet deposition calculations, defined as cloud-processing error, and range from 20 to 15 in most regions for CN70CN100 concentrations. Overall, the Fast TOMAS models increase the computational speed by 2 to 3 times with only small numerical errors stemming from condensation and coagulation calculations when compared to TOMAS-30. The faster versions of the TOMAS model allow for the longer, multi-year simulations required to assess aerosol effects on cloud lifetime and precipitation.
Lima, Letícia S M S; De Almeida, Ronei; Quintaes, Bianca R; Bila, Daniele M; Campos, Juacyara C
2017-07-29
This study aimed to evaluate the use of coagulation/flocculation and Fenton processes for the removal of the recalcitrant component, in particular humic substances, from two different leachates generated in the Gericinó and Gramacho landfills in Rio de Janeiro State (Brazil). A coagulation/flocculation process, using FeCl 3 ·6H 2 O as the coagulant, was applied to the two leachate samples. In the case of the leachate from Gericinó landfill, the treatment removed 93% of color, 71% of TOC, 69% of COD, 76% of HS, 73% of humic acids (HA) and 82% of fulvic acids (FA). In addition, there was a 75% reduction in the absorbance at 254 nm, using 3,000 mg L -1 of coagulant. In the case of the leachate from Gramacho landfill, the treatment removed 91% of color, 69% of TOC, 68% of COD, 77% of HS, 75% of HA and 80% of FA. In addition, there was a 70% reduction in the absorbance at 254 nm using the same concentration of coagulant (3,000 mg L -1 ). The Fenton processes, using FeSO 4 ·7H 2 O and H 2 O 2 in a ratio of 1:5, were also applied to the two leachate samples. In the case of the Gericinó leachate, the Fenton treatment removed 95% of color, 75% of TOC, 68% of COD, 82% of HS, 77% of HA and 93% of FA. In addition, there was a 93% reduction in the absorbance at 254 nm. In the case of the Gramacho leachate, the Fenton treatment removed 93% of color, 73% of TOC, 71% of COD, 81% of HS, 76% of HA, 90% of FA, and there was an 84% reduction in the absorbance at 254 nm. The results of humic substances, color, organic matter and aromatic organic matter (absorbance at 254 nm) demonstrate that the coagulation/flocculation and Fenton processes were efficient in the removal of recalcitrant organic matter from landfill leachates.
Influence of micellar calcium and phosphorus on rennet coagulation properties of cows milk.
Malacarne, Massimo; Franceschi, Piero; Formaggioni, Paolo; Sandri, Sandro; Mariani, Primo; Summer, Andrea
2014-05-01
The main requirement for milk processed in most cheese typologies is its rennet coagulation ability. Despite the increasing number of studies, the causes for abnormal coagulation of milk are not fully understood. The aim of this study was to ascertain relationships between milk characteristics and its rennet coagulation ability, focusing on the influence of calcium (Ca) and phosphorus (P). Ca and P are essential constituents of the micelles. Micellar P can be present as part of colloidal calcium phosphate (inorganic-P) or covalently bound to caseins as phosphate groups (casein-P). Eighty one herd milk samples (SCC<400 000 cell/ml) were classified as Optimal (8), Suboptimal (39) Poor (29) and Non-coagulating milk (5), according to their rennet coagulation parameters as assessed by lactodynamographic test. Samples were analysed for their chemical composition (basic composition, protein fractions, minerals and salt equilibria), physicochemical parameters (pH and titratable acidity) and rheological properties. Optimal milk was characterised by the highest contents of major constituents, protein fractions and minerals, lowest content of chloride and highest values of titratable acidity. Non-coagulating milk was characterised by the highest values of pH and the lowest of titratable acidity. At micellar level, Optimal milk showed the highest values of colloidal Ca, casein-P and colloidal Mg (g/100 g casein), while Non-coagulating milk showed the lowest values. Interestingly, there was no statistical difference regarding the content of colloidal inorganic-P (g/100 g casein) between Optimal and Non-coagulating milks. Overall, high mineralisation of the micelle (expressed as g inorganic-P/100 g casein) positively affect its rennetability. However, excessive mineralisation could lead to a reduction of the phosphate groups (g casein-P/100 g casein) available for curd formation.
Bongiovani, Milene Carvalho; Camacho, Franciele Pereira; Nishi, Letícia; Coldebella, Priscila Ferri; Valverde, Karina Cardoso; Vieira, Angélica Marquetotti Salcedo; Bergamasco, Rosângela
2014-01-01
The objective of this study is to investigate the impacts of anionic polymer as a flocculant aid on the coagulation/flocculation performance with a saline solution of Moringa oleifera as a coagulant to provide larger flocs and decrease the time sedimentation. For the tests, raw water was used from Pirapó River Basin (Maringá, Paraná, Brazil). Optimization of coagulation/flocculation tests was initially performed in a jar-test with a dosage of M. oleifera Lam (crude extract--MO, oil-extracted with ethanol--MO (et) and hexane--MO (hex) 1% m/v) as the coagulant that ranged from 10 to 60 mg L(-1) and of the anionic polymer 0.1% as a flocculant aid with a dosage that ranged from 0 to 0.4 mg L(-1). The parameters analysed were colour, turbidity and compounds with absorption in UV254nm. In view of the statistical analysis results, MO (hex) with a dosage of 30 mg L(-1) was chosen as a coagulant for the next tests of coagulation/flocculation. When anionic polymer was used alone (0.0 mg L(-1) of MO (hex)), parameters were not removed and there was no generation of heavy flocs as compared with the combination of MO (hex) with the anionic polymer. Statistical analysis showed that MO (hex) obtained the highest removals of the parameters analysed in lower dosages and no significant increase in parameters removal was observed when the polymer dosage was increased. The efficacy of the coagulant +/- anionic polymer was optimal when 30mg L(-1) of MO (hex) was used as a coagulant and 0.1 mg L(-1) of the anionic polymer was used as a flocculant aid, decreasing the time sedimentation from 1 h to 15 min.
The use of smoke acid as an alternative coagulating agent for natural rubber sheets' production.
Ferreira, Vanda S; Rêgo, Ione N C; Pastore, Floriano; Mandai, Mariana M; Mendes, Leonardo S; Santos, Karin A M; Rubim, Joel C; Suarez, Paulo A Z
2005-03-01
A comparative study of rubber sheets obtained using formic, acetic, and smoke acid as coagulants is shown for latex obtained from native Amazonian trees and also from commercial cultivated trees. The evaluation of both processes of coagulation was carried out by spectroscopic and physical-chemical analysis, showing no differences in the rubber sheets obtained. This new method of rubber sheet preparation was introduced into Amazonian rainforest rubber tapper communities, which are actually producing in large scale. The physical-mechanical properties were similar among a large sheets made by different rubber tapper communities using this new method.
Dust Coagulation in Protoplanetary Accretion Disks
NASA Technical Reports Server (NTRS)
Schmitt, W.; Henning, Th.; Mucha, R.
1996-01-01
The time evolution of dust particles in circumstellar disk-like structures around protostars and young stellar objects is discussed. In particular, we consider the coagulation of grains due to collisional aggregation. The coagulation of the particles is calculated by solving numerically the non-linear Smoluchowski equation. The different physical processes leading to relative velocities between the grains are investigated. The relative velocities may be induced by Brownian motion, turbulence and drift motion. Starting from different regimes which can be identified during the grain growth we also discuss the evolution of dust opacities. These opacities are important for both the derivation of the circumstellar dust mass from submillimeter/millimeter continuum observations and the dynamical behavior of the disks. We present results of our numerical studies of the coagulation of dust grains in a turbulent protoplanetary accretion disk described by a time-dependent one-dimensional (radial) alpha-model. For several periods and disk radii, mass distributions of coagulated grains have been calculated. From these mass spectra, we determined the corresponding Rosseland mean dust opacities. The influence of grain opacity changes due to dust coagulation on the dynamical evolution of a protostellar disk is considered. Significant changes in the thermal structure of the protoplanetary nebula are observed. A 'gap' in the accretion disk forms at the very frontier of the coagulation, i.e., behind the sublimation boundary in the region between 1 and 5 AU.
1986-05-01
METHYL NETHACRYLATE) PROCESSED ON ELECTROLYTICALLY ETCHED TICONIUM A THESIS Presented to the Faculty of The University of Texas Graduate School of...were cast utilizing the manufacturer’s directions for investment, burnout , and casting. Two groups of metal specimens were prepared: 20 for...STRENGTHS OF POLY (METHYL METHACRYLATE) PROCESSED ON ELECTROLYTICALLY ETCHED TICONIUM JOHN EDWARD ZURASKY, M.S. The University of Texas Graduate School
Nasution, M Ansori; Yaakob, Z; Ali, Ehsan; Tasirin, S M; Abdullah, S R S
2011-01-01
Palm oil mill effluent (POME) is highly polluting wastewater generated from the palm oil milling process. Palm oil mill effluent was used as an electrolyte without any additive or pretreatment to perform electrocoagulation (EC) using electricity (direct current) ranging from 2 to 4 volts in the presence of aluminum electrodes with a reactor volume of 20 L. The production of hydrogen gas, removal of chemical oxygen demand (COD), and turbidity as a result of electrocoagulation of POME were determined. The results show that EC can reduce the COD and turbidity of POME by 57 and 62%, respectively, in addition to the 42% hydrogen production. Hydrogen production was also helpful to remove the lighter suspended solids toward the surface. The production of Al(OH)XHO at the aluminum electrode (anode) was responsible for the flocculation-coagulation process of suspended solids followed by sedimentation under gravity. The production of hydrogen gas from POME during EC was also compared with hydrogen gas production by electrolysis of tap water at pH 4 and tap water without pH adjustment under the same conditions. The main advantage of this study is to produce hydrogen gas while treating POME with EC to reduce COD and turbidity effectively. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Abood, Alkhafaji R; Bao, Jianguo; Du, Jiangkun; Zheng, Dan; Luo, Ye
2014-02-01
This study describes the complete treatment of non-biodegradable landfill leachate by combined treatment processes. The processes consist of agitation as a novel stripping method used to overcome the ammonia toxicity regarding aerobic microorganisms. The NH3-N removal ratio was 93.9% obtained at pH 11.5 and a gradient velocity (G) 150 s(-1) within a five-hour agitation time. By poly ferric sulphate (PFS) coagulation followed the agitation process; chemical oxygen demand (COD) and biological oxygen demand (BOD5) were removed at 70.6% and 49.4%, respectively at an optimum dose of 1200 mg L(-1) at pH 5.0. The biodegradable ratio BOD5/COD was improved from 0.18 to 0.31 during pretreatment step by agitation and PFS coagulation. Thereafter, the effluent was diluted with sewage at a different ratio before it was subjected to sequencing batch reactor (SBR) treatment. Up to 93.3% BOD5, 95.5% COD and 98.1% NH3-N removal were achieved by SBR operated under anoxic-aerobic-anoxic conditions. The filtration process was carried out using sand and carbon as a dual filter media as polishing process. The final effluent concentration of COD, BOD5, suspended solid (SS), NH3-N and total organic carbon (TOC) were 72.4 mg L(-1), 22.8 mg L(-1), 24.2 mg L(-1), 18.4 mg L(-1) and 50.8 mg L(-1) respectively, which met the discharge standard. The results indicated that a combined process of agitation-coagulation-SBR and filtration effectively eliminated pollutant loading from landfill leachate. Copyright © 2013 Elsevier Ltd. All rights reserved.
David, J S; Imhoff, E; Parat, S; Augey, L; Geay-Baillat, M-O; Incagnoli, P; Tazarourte, K
2016-11-01
Viscoelastic technics are used for 10 years and include the ROTEM ® and the TEG ® . These devices that exploit the viscoelastic properties of the clotting blood, allow a rapid and global analysis of the haemostatic process taking into account all the process interfering with haemostasis such as inflammation. It has been shown that the use of these technics in clinical situations such as trauma, postpartum haemorrhage, gastrointestinal bleeding or cardiac surgery may reduce the need for blood product, the cost and perhaps may improve the outcome of the patients. Thanks to a rapid identification of the underlying coagulation deficit, these technics facilitate decision-making during acute care and help to guide the treatment, particularly with coagulation factor's concentrate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Coagulation of dust particles in a plasma
NASA Technical Reports Server (NTRS)
Horanyi, M.; Goertz, C. K.
1990-01-01
The electrostatic charge of small dust grains in a plasma in which the temperature varies in time is discussed, pointing out that secondary electron emission might introduce charge separation. If the sign of the charge on small grains is opposite to that on big ones, enhanced coagulation can occur which will affect the size distribution of grains in a plasma. Two scenarios where this process might be relevant are considered: a hot plasma environment with temperature fluctuations and a cold plasma environment with transient heating events. The importance of the enhanced coagulation is uncertain, because the plasma parameters in grain-producing environments such as a molecular cloud or a protoplanetary disk are not known. It is possible, however, that this process is the most efficient mechanism for the growth of grains in the size range of 0.1-500 microns.
Dong, Bingzhi; Gui, Bo; Liu, Junxia; Wang, Zhihong; Tan, Kaiting
2018-06-01
This paper analysed organic foulants in the coagulation-microfiltration process for Taihu Lake treatment. High-performance size-exclusion chromatography (HPSEC) and fluorescence excitation-emission matrices (EEM) were applied to elucidate the influence of characteristics of organics on microfiltration (MF) membrane fouling. Results showed that coagulation pretreatment could extend the operation duration of MF based on the fact that pretreatment could effectively remove macromolecular substances as well as a portion of small molecular weight (MW) organics. The analysis of foulants indicated that organics of strong hydrophobic acids (SHA) and neutral hydrophilic (Neut) fractions (based on hydrophobicity) and medium and small MW components (based on MW distribution) contributed greatly to irreversible fouling. EEM fluorescence analysis of chemical solutions exhibited that aromatic proteins and soluble microbial products were mainly a response to irreversible fouling.
Cui, Xiaochun; Zhou, Dandan; Fan, Wei; Huo, Mingxin; Crittenden, John C; Yu, Zhisen; Ju, Pengfei; Wang, Yang
2016-08-01
Coagulation is a feasible process to reclaim municipal wastewater, however, the role of coagulation in removing effluent organic matter (EfOM) from underutilized wastewater treatment plants (WWTPs) has not been fully explored. We identified the characteristics of the EfOM from a typical underutilized WWTP (i.e., the ratio of actual capacity to design capacity is 50%-70%), and investigated the performance of coagulation on suspended solids (SS) and dissolved organic matter (DOM) removal. The effluent could even satisfy the highest national standard of China (Class 1 A) for WWTP effluent, as evaluated by the traditional parameters such as SS and chemical oxygen demand (COD). However, the DOM in the EfOM we studied contained considerable biomass-associated products (BAPs), which were dominated by proteins with a molecular weight of approximately 150 kDa. In addition, protein also dominated the DOM after coagulation. Fulvic acid and humic-like acid organics were poorly removed by either AlCl3 or polyaluminum chloride (PAC) coagulation, even with a dosage as high as 24 mg Al L(-1). Biodegradability was very poor, as the ratio of biological oxygen demand (BOD5) to COD was less than 0.17. After coagulation the typical BAPs, protein and polysaccharide, remained as high as 1.6 mg L(-1) and 1.2 mg L(-1) respectively. In this study we found coagulation was ineffective for removal of recalcitrant BAPs. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rambe, AM; Pandia, S.; Ginting, MHS; Tambun, R.; Haryanto, B.
2018-02-01
This research is to know the influence of moringa seed as coagulant, pH of liquid waste textile industry (jeans wash), size of moringa seed particles to decrease of turbidity percentage. Measurements were made to Total Suspended Solid, Color Rate and Chemical Oxygen Demand for wastewater textile industry by coagulation - flocculation method. Variables of this study were conducted on dosage of moringa, with particle size 212 mesh. The results showed that moringa seeds as coagulant dose optimum is 1250 mg/L for the textile industry wastewater at pH 7.8. Moringa seed powder is about 212 mesh with a dose of 1250 mg/L can lower the turbidity of 77.77%, Total Suspended Solid amounted to 83.69% and Chemical Oxygen Demand amounted to 75.86%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zou Yu, E-mail: yzou@Princeton.ED; Kavousanakis, Michail E., E-mail: mkavousa@Princeton.ED; Kevrekidis, Ioannis G., E-mail: yannis@Princeton.ED
2010-07-20
The study of particle coagulation and sintering processes is important in a variety of research studies ranging from cell fusion and dust motion to aerosol formation applications. These processes are traditionally simulated using either Monte-Carlo methods or integro-differential equations for particle number density functions. In this paper, we present a computational technique for cases where we believe that accurate closed evolution equations for a finite number of moments of the density function exist in principle, but are not explicitly available. The so-called equation-free computational framework is then employed to numerically obtain the solution of these unavailable closed moment equations bymore » exploiting (through intelligent design of computational experiments) the corresponding fine-scale (here, Monte-Carlo) simulation. We illustrate the use of this method by accelerating the computation of evolving moments of uni- and bivariate particle coagulation and sintering through short simulation bursts of a constant-number Monte-Carlo scheme.« less
Cui, Jinli; Jing, Chuanyong; Che, Dongsheng; Zhang, Jianfeng; Duan, Shuxuan
2015-06-01
Elevated arsenic (As) in groundwater poses a great threat to human health. Coagulation using mono- and poly-Fe salts is becoming one of the most cost-effective processes for groundwater As removal. However, a limitation comes from insufficient understanding of the As removal mechanism from groundwater matrices in the coagulation process, which is critical for groundwater treatment and residual solid disposal. Here, we overcame this hurdle by utilizing microscopic techniques to explore molecular As surface complexes on the freshly formed Fe flocs and compared ferric(III) sulfate (FS) and polyferric sulfate (PFS) performance, and finally provided a practical solution in As-geogenic areas. FS and PFS exhibited a similar As removal efficiency in coagulation and coagulation/filtration in a two-bucket system using 5mg/L Ca(ClO)2. By using the two-bucket system combining coagulation and sand filtration, 500 L of As-safe water (<10 μg/L) was achieved during five treatment cycles by washing the sand layer after each cycle. Fe k-edge X-ray absorption near-edge structure (XANES) and As k-edge extended X-ray absorption fine structure (EXAFS) analysis of the solid residue indicated that As formed a bidentate binuclear complex on ferrihydrite, with no observation of scorodite or poorly-crystalline ferric arsenate. Such a stable surface complex is beneficial for As immobilization in the solid residue, as confirmed by the achievement of much lower leachate As (0.9 μg/L-0.487 mg/L) than the US EPA regulatory limit (5 mg/L). Finally, PFS is superior to FS because of its lower dose, much lower solid residue, and lower cost for As-safe drinking water. Copyright © 2015. Published by Elsevier B.V.
Wang, Dongsheng; Xing, Linan; Xie, Jiankun; Chow, Christopher W K; Xu, Zhizhen; Zhao, Yanmei; Drikas, Mary
2010-09-01
China has a very complex water supply system which relies on many rivers and lakes. As the population and economic development increases, water quality is greatly impacted by anthropogenic processes. This seriously affects the character of the dissolved organic matter (DOM) and imposes operational challenges to the water treatment facilities in terms of process optimization. The aim of this investigation was to compare selected drinking water sources (raw) with different DOM character, and the respective treated waters after coagulation, using simple organic characterization techniques to obtain a better understanding of the impact of source water quality on water treatment. Results from the analyses of selected water samples showed that the dissolved organic carbon (DOC) of polluted waters is generally higher than that of un-polluted waters, but the specific UV absorbance value has the opposite trend. After resolving the high performance size exclusion chromatography (HPSEC) peak components of source waters using peak fitting, the twelve waters studied can be divided into two main groups (micro-polluted and un-polluted) by using cluster analysis. The DOM removal efficiency (treatability) of these waters has been compared using four coagulants. For water sources allocated to the un-polluted group, traditional coagulants (Al(2)(SO(4))(3) and FeCl(3)) achieved better removal. High performance poly aluminum chloride, a new type of composite coagulant, performed very well and more efficiently for polluted waters. After peak fitting the HPSEC chromatogram of each of the treated waters, average removal efficiency of the profiles can be calculated and these correspond well with DOC and UV removal. This provides a convenient tool to assess coagulation removal and coagulant selection. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Wu, Ying; Wang, Jixiao; Ou, Bin; Zhao, Song; Wang, Zhi; Wang, Shichang
2018-02-12
Electrochemical polymerization of aniline is one of the most promising methods to prepare polyaniline (PANI) materials. However, during this process, the electrolyte solution must be replaced after electropolymerization of a certain time because of the generation and the accumulation of the by-products, which have significant effects on the morphology, purity and properties of PANI products. Treatment and recycling of the used electrolyte solution are worthwhile to study to reduce the high treatment cost of the used electrolyte solution containing aniline and its polymerization by-products. Here, the composition of the used electrolyte solution was separated and determined by high performance liquid chromatography coupled with diode array detection (HPLC-DAD) in the range of ultraviolet and visible (UV-Vis) light. The analysis results revealed that the used electrolyte solution consisted of aniline, p-hydroquinone (HQ), p-benzoquinone (BQ), co-oligomers of aniline and p-benzoquinone (CAB) and acid. Then, n-octanol and 2-octanone were selected as extracts to remove HQ, BQ and CAB from the used electrolyte solution. Following that, the recycled electrolyte solution was prepared by adjusting the concentration of aniline and acid of the aqueous phase, and the electrochemical polymerization process was conducted. Finally, the obtained PANI was characterized by scanning electron microscope (SEM) and electrochemical methods. The experimental results clearly demonstrate that the morphology and specific capacitance of PANI produced from the recycled electrolyte solution can be recovered completely. This research paves the way for reusing the used electrolyte solution for aniline electrochemical polymerization.
Wu, Ying; Wang, Jixiao; Ou, Bin; Zhao, Song; Wang, Zhi; Wang, Shichang
2018-01-01
Electrochemical polymerization of aniline is one of the most promising methods to prepare polyaniline (PANI) materials. However, during this process, the electrolyte solution must be replaced after electropolymerization of a certain time because of the generation and the accumulation of the by-products, which have significant effects on the morphology, purity and properties of PANI products. Treatment and recycling of the used electrolyte solution are worthwhile to study to reduce the high treatment cost of the used electrolyte solution containing aniline and its polymerization by-products. Here, the composition of the used electrolyte solution was separated and determined by high performance liquid chromatography coupled with diode array detection (HPLC-DAD) in the range of ultraviolet and visible (UV-Vis) light. The analysis results revealed that the used electrolyte solution consisted of aniline, p-hydroquinone (HQ), p-benzoquinone (BQ), co-oligomers of aniline and p-benzoquinone (CAB) and acid. Then, n-octanol and 2-octanone were selected as extracts to remove HQ, BQ and CAB from the used electrolyte solution. Following that, the recycled electrolyte solution was prepared by adjusting the concentration of aniline and acid of the aqueous phase, and the electrochemical polymerization process was conducted. Finally, the obtained PANI was characterized by scanning electron microscope (SEM) and electrochemical methods. The experimental results clearly demonstrate that the morphology and specific capacitance of PANI produced from the recycled electrolyte solution can be recovered completely. This research paves the way for reusing the used electrolyte solution for aniline electrochemical polymerization. PMID:29439514
NASA Technical Reports Server (NTRS)
Nuth, J. A.; Rietmeijer, F. J. M.; Hallenbeck, S. L.; Withey, P. A.
1999-01-01
Starting with cooling, refractory vapors diluted in significant quantities of H and He there are four processes that most natural systems will undergo: nucleation, growth, annealing, and coagulation. Nucleation is the processes by which the first stable refractory nuclei form in the vapor. These are the seeds onto which the remaining vapors will condense during the growth stage. Solids of any composition will try to arrange themselves into the least energetic configuration, provided that there is sufficient energy available to support such processes as diffusion and the breaking of chemical bonds. There is a significant activation energy associated with the annealing process in refractory solids due to the relatively high energy of the chemical bonds in solids. The grains formed in most cosmochemical systems are extremely small and often tightly coupled to the gas. Because of their small physical cross sections coagulation may be a very slow process unless there is another driving force involved in addition to normal Brownian motion. In what follows we will briefly cover each of these four stages for refractory oxide and metal grains, although in inverse order.
Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E; Boudoux, Caroline
2015-04-01
Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett's esophagus.
Vilaseca, Mercè; López-Grimau, Víctor; Gutiérrez-Bouzán, Carmen
2014-09-12
Moringa oleifera seeds contain about 40% of highly valued oil due to its wide range of applications, from nutritional issues to cosmetics or biodiesel production. The extraction of Moringa oil generates a waste (65%-75% of seeds weight) which contains a water soluble protein able to be used either in drinking water clarification or wastewater treatment. In this paper, the waste of Moringa oleifera extraction was used as coagulant to remove five reactive dyes from synthetic textile effluents. This waste constitutes a natural coagulant which was demonstrated to be effective for the treatment of industrial reactive dyestuff effluents, characterized by alkaline pH, high NaCl content and hydrolyzed dyes. The coagulation yield increased at high NaCl concentration, whereas the pH did not show any significant effect on dye removal. Moringa oleifera showed better results for dye removal than the conventional treatment of coagulation-flocculation with FeCl₃ and polyelectrolyte. Treated water can be reused in new dyeing processes of cotton fabrics with high quality results.
Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline
2015-01-01
Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett’s esophagus. PMID:25909013
Vilaseca, Mercè; López-Grimau, Víctor; Gutiérrez-Bouzán, Carmen
2014-01-01
Moringa oleifera seeds contain about 40% of highly valued oil due to its wide range of applications, from nutritional issues to cosmetics or biodiesel production. The extraction of Moringa oil generates a waste (65%–75% of seeds weight) which contains a water soluble protein able to be used either in drinking water clarification or wastewater treatment. In this paper, the waste of Moringa oleifera extraction was used as coagulant to remove five reactive dyes from synthetic textile effluents. This waste constitutes a natural coagulant which was demonstrated to be effective for the treatment of industrial reactive dyestuff effluents, characterized by alkaline pH, high NaCl content and hydrolyzed dyes. The coagulation yield increased at high NaCl concentration, whereas the pH did not show any significant effect on dye removal. Moringa oleifera showed better results for dye removal than the conventional treatment of coagulation-flocculation with FeCl3 and polyelectrolyte. Treated water can be reused in new dyeing processes of cotton fabrics with high quality results. PMID:28788199
Oliveira, Gislayne Alves; Carissimi, Elvis; Monje-Ramírez, Ignacio; Velasquez-Orta, Sharon B; Rodrigues, Rafael Teixeira; Ledesma, María Teresa Orta
2018-07-01
The removal of nutrients by Scenedesmus sp. in a high-rate algal pond, and subsequent algal separation by coagulation-flocculation or flotation with ozone to recover biomolecules, were evaluated. Cultivation of Scenedesmus sp. in wastewater resulted in complete NH 3 -H removal, plus 93% total nitrogen and 61% orthophosphate removals. Ozone-flotation obtained better water quality results than coagulation-flocculation for most parameters (NH 3 -N, NTK, nitrate and nitrite) except orthophosphate. Ozone-flotation, also produced the highest recovery of lipids, carbohydrates and proteins which were 0.32 ± 0.03, 0.33 ± 0.025 and 0.58 ± 0.014 mg/mg of biomass, respectively. In contrast, there was a low lipid extraction of 0.21 mg of lipids/mg of biomass and 0.12-0.23 mg of protein/mg of biomass in the coagulation-flocculation process. In terms of biomolecule recovery and water quality, ozone showed better results than coagulation-flocculation. Copyright © 2018 Elsevier Ltd. All rights reserved.
Selection of the surface water treatment technology - a full-scale technological investigation.
Pruss, Alina
2015-01-01
A technological investigation was carried out over a period of 2 years to evaluate surface water treatment technology. The study was performed in Poland, in three stages. From November 2011 to July 2012, for the first stage, flow tests with a capacity of 0.1-1.5 m³/h were performed simultaneously in three types of technical installations differing by coagulation modules. The outcome of the first stage was the choice of the technology for further investigation. The second stage was performed between September 2012 and March 2013 on a full-scale water treatment plant. Three large technical installations, operated in parallel, were analysed: coagulation with sludge flotation, micro-sand ballasted coagulation with sedimentation, coagulation with sedimentation and sludge recirculation. The capacity of the installations ranged from 10 to 40 m³/h. The third stage was also performed in a full-scale water treatment plant and was aimed at optimising the selected technology. This article presents the results of the second stage of the full-scale investigation. The critical treatment process, for the analysed water, was the coagulation in an acidic environment (6.5 < pH < 7.0) carried out in a system with rapid mixing, a flocculation chamber, preliminary separation of coagulation products, and removal of residual suspended solids through filtration.
Chuntarut, A; Tientadakul, P; Wongkrajang, P
2016-06-01
The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.
Shen, Feng; Pompano, Rebecca R; Kastrup, Christian J; Ismagilov, Rustem F
2009-10-21
This study shows that environmental confinement strongly affects the activation of nonlinear reaction networks, such as blood coagulation (clotting), by small quantities of activators. Blood coagulation is sensitive to the local concentration of soluble activators, initiating only when the activators surpass a threshold concentration, and therefore is regulated by mass transport phenomena such as flow and diffusion. Here, diffusion was limited by decreasing the size of microfluidic chambers, and it was found that microparticles carrying either the classical stimulus, tissue factor, or a bacterial stimulus, Bacillus cereus, initiated coagulation of human platelet-poor plasma only when confined. A simple analytical argument and numerical model were used to describe the mechanism for this phenomenon: confinement causes diffusible activators to accumulate locally and surpass the threshold concentration. To interpret the results, a dimensionless confinement number, Cn, was used to describe whether a stimulus was confined, and a Damköhler number, Da(2), was used to describe whether a subthreshold stimulus could initiate coagulation. In the context of initiation of coagulation by bacteria, this mechanism can be thought of as "diffusion acting", which is distinct from "diffusion sensing". The ability of confinement and diffusion acting to change the outcome of coagulation suggests that confinement should also regulate other biological "on" and "off" processes that are controlled by thresholds.
Abrams, Charles S.
2012-01-01
Abstract Disseminated intravascular coagulation (DIC) profoundly increases the morbidity and mortality of patients who have sepsis. Both laboratory and clinical research advanced the understanding of the biology and pathophysiology of DIC. This, in turn, gave rise to improved therapies and patient outcomes. Beginning with a stimulus causing disruption of vascular integrity, cytokines and chemokines cause activation of systemic coagulation and inflammation. Seemingly paradoxically, the interplay between coagulation and inflammation also inhibits endogenous anticoagulants, fibrinolytics, and antiinflammatory pathways. The earliest documented and best‐studied microbial cause of DIC is the lipopolysaccharide endotoxin of Gram‐negative bacteria. Extensive microvascular thrombi emerge in the systemic vasculature due to dysregulation of coagulation. The result of this unrestrained, widespread small vessel thromboses multiorgan system failure. Consumption of platelets and coagulation factors during this process can lead to an elevated risk of hemorrhage. The management of these patients with simultaneous hemorrhage and thrombosis is complex and challenging. Definitive treatment of DIC, and attenuation of end‐organ damage, requires control of the inciting cause. Currently, activated protein C is the only approved therapy in the United States for sepsis complicated by DIC. Further research is needed in this area to improve clinical outcomes for patients with sepsis. Clin Trans Sci 2012; Volume 5: 85–92 PMID:22376264
Elastic scattering spectroscopy of coagulated brain tissues
NASA Astrophysics Data System (ADS)
Ateş, Filiz; Tabakoğlu, Haşim Özgür; Bozkulak, Özgüncem; Canpolat, Murat; Gülsoy, Murat
2006-02-01
The goal of this study was to differentiate the parts of lamb brain according to elastic scattering spectroscopy and detect the optical alterations due to coagulation. Cells and tissues are not uniform and have complex structures and shapes. They can be referred to as scattering particles. The process of scattering depends on the light wavelength and on the scattering medium properties; especially on the size and the density of the medium. When elastic scattering spectroscopy (ESS) is employed, the morphological alterations of tissues can be detected using spectral measurements of the elastic scattered light over a wide range of wavelengths. In this study firstly, the slopes of ESS spectra were used to differentiate the parts of lamb brains (brainstem, cerebellum, gray matter, white matter) in vitro in the range of 450 - 750 nm. Secondly, tissues were coagulated at different temperatures (45, 60, and 80 °C) and ESS spectra were taken from native and coagulated tissues. It was observed that as the coagulation temperature increased, the slope of the elastic scattering spectra decreased. Thus, optical properties of tissues were changed with respect to the change in nuclear to cytoplasmic ratio due to the water loss. Results showed that the slopes of ESS spectra in the visible range revealed valuable information about the morphological changes caused by coagulation.
Electrodeposition of magnesium and magnesium/aluminum alloys
Mayer, Anton
1988-01-01
Electrolytes and plating solutions for use in processes for electroplating and electroforming pure magnesium and alloys of aluminum and magnesium and also electrodeposition processes. An electrolyte of this invention is comprised of an alkali metal fluoride or a quaternary ammonium halide, dimethyl magnesium and/or diethyl magnesium, and triethyl aluminum and/or triisobutyl aluminum. An electrolyte may be dissolved in an aromatic hydrocarbon solvent to form a plating solution. The proportions of the component compounds in the electrolyte are varied to produce essentially pure magnesium or magnesium/aluminum alloys having varying selected compositions.
Electrowinning process with electrode compartment to avoid contamination of electrolyte
Poa, Davis S.; Pierce, R. Dean; Mulcahey, Thomas P.; Johnson, Gerald K.
1993-01-01
An electrolytic process and apparatus for reducing calcium oxide in a molten electrolyte of CaCl.sub.2 -CaF.sub.2 with a graphite anode in which particles or other contamination from the anode is restricted by the use of a porous barrier in the form of a basket surrounding the anode which may be removed from the electrolyte to burn the graphite particles, and wherein the calcium oxide feed is introduced to the anode compartment to increase the oxygen ion concentration at the anode.
Electrodeposition of magnesium and magnesium/aluminum alloys
Mayer, A.
1988-01-21
Electrolytes and plating solutions for use in processes for electroplating and electroforming pure magnesium and alloys of aluminum and magnesium and also electrodeposition processes. An electrolyte of this invention is comprised of an alkali metal fluoride or a quaternary ammonium halide, dimethyl magnesium and/or diethyl magnesium, and triethyl aluminum and/or triisobutyl aluminum. An electrolyte may be dissolved in an aromatic hydrocarbon solvent to form a plating solution. The proportions of the component compounds in the electrolyte are varied to produce essentially pure magnesium or magnesium/aluminum alloys having varying selected compositions.
Potable water recovery for spacecraft application by electrolytic pretreatment/air evaporation
NASA Technical Reports Server (NTRS)
Wells, G. W.
1975-01-01
A process for the recovery of potable water from urine using electrolytic pretreatment followed by distillation in a closed-cycle air evaporator has been developed and tested. Both the electrolytic pretreatment unit and the air evaporation unit are six-person, flight-concept prototype, automated units. Significantly extended wick lifetimes have been achieved in the air evaporation unit using electrolytically pretreated, as opposed to chemically pretreated, urine feed. Parametric test data are presented on product water quality, wick life, process power, maintenance requirements, and expendable requirements.
Cheng, Xiaoxiang; Liang, Heng; Ding, An; Zhu, Xuewu; Tang, Xiaobin; Gan, Zhendong; Xing, Jiajian; Wu, Daoji; Li, Guibai
2017-11-01
Coagulation and ozonation have been widely used as pretreatments for ultrafiltration (UF) membrane in drinking water treatment. While beneficial, coagulation or ozonation alone is unable to both efficiently control membrane fouling and product water quality in many cases. Thus, in this study an emerging alternative of ferrous iron/peroxymonosulfate (Fe(II)/PMS), which can act as both an oxidant and a coagulant was employed prior to UF for treatment of natural surface water, and compared with conventional coagulation and ozonation. The results showed that the Fe(II)/PMS-UF system exhibited the best performance for dissolved organic carbon removal, likely due to the dual functions of coagulation and oxidation in the single process. The fluorescent and UV-absorbing organic components were more susceptible to ozonation than Fe(II)/PMS treatment. Fe(II)/PMS and ozonation pretreatments significantly increased the removal efficiency of atrazine, p-chloronitrobenzene and sulfamethazine by 12-76% and 50-94%, respectively, whereas coagulation exerted a minor influence. The Fe(II)/PMS pretreatment also showed the best performance for the reduction of both reversible and irreversible membrane fouling, and the performance was hardly affected by membrane pore size and surface hydrophobicity. In addition, the characterization of hydraulic irreversible organic foulants confirmed its effectiveness. These results demonstrate the potential advantages of applying Fe(II)/PMS as a pretreatment for UF to simultaneously control membrane fouling and improve the permeate quality. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lin, Jr-Lin; Hua, Lap-Cuong; Hung, Shih Kai; Huang, Chihpin
2018-01-01
The cyanobacteria-bloom in raw waters frequently causes an unpredictable chemical dosing of preoxidation and coagulation for an effective removal of algal cells in water treatment plants. This study investigated the effects of preoxidation with NaOCl and ClO 2 on the coagulation-flotation effectiveness in the removal of two commonly blooming cyanobacteria species, Microcystis aeruginosa (MA) and Cylindrospermopsis raciborskii (CR), and their corresponding trihalomethane (THM) formation potential. The results showed that dual dosing with NaOCl plus ClO 2 was more effective in enhancing the deformation of cyanobacterial cells compared to single dosing with NaOCl, especially for CR-rich water. Both preoxidation approaches for CR-rich water effectively reduced the CR cell count with less remained dissolved organic carbon (DOC), which benefited subsequent coagulation-flotation. However, preoxidation led to an adverse release of algogenic organic matter (AOM) in the case of MA-rich water. The release of AOM resulted in a poor removal in MA cells and a large amount of THM formation after oxidation-assisted coagulation-flotation process. The reduction in THM formation potential of CR-rich waters is responsible for effective algae and DOC removal by alum coagulation. It is concluded that the species-specific characteristic of cyanobacteria and their AOM released during chlorination significantly influences the performance of coagulation-flotation for AOM removal and corresponding THM formation. Copyright © 2017. Published by Elsevier B.V.
Shibeko, Alexey M; Panteleev, Mikhail A
2016-05-01
Blood coagulation is a complex biochemical network that plays critical roles in haemostasis (a physiological process that stops bleeding on injury) and thrombosis (pathological vessel occlusion). Both up- and down-regulation of coagulation remain a major challenge for modern medicine, with the ultimate goal to correct haemostasis without causing thrombosis and vice versa. Mathematical/computational modelling is potentially an important tool for understanding blood coagulation disorders and their treatment. It can save a huge amount of time and resources, and provide a valuable alternative or supplement when clinical studies are limited, or not ethical, or technically impossible. This article reviews contemporary state of the art in the modelling of blood coagulation for practical purposes: to reveal the molecular basis of a disease, to understand mechanisms of drug action, to predict pharmacodynamics and drug-drug interactions, to suggest potential drug targets or to improve quality of diagnostics. Different model types and designs used for this are discussed. Functional mechanisms of procoagulant bypassing agents and investigations of coagulation inhibitors were the two particularly popular applications of computational modelling that gave non-trivial results. Yet, like any other tool, modelling has its limitations, mainly determined by insufficient knowledge of the system, uncertainty and unreliability of complex models. We show how to some extent this can be overcome and discuss what can be expected from the mathematical modelling of coagulation in not-so-far future. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Terenji, Albert; Willmann, Stefan; Osterholz, Jens; Hering, Peter; Schwarzmaier, Hans-Joachim
2005-06-01
During heating, the optical properties of biological tissues change with the coagulation state. In this study, we propose a technique, which uses these changes to monitor the coagulation process during laser-induced interstitial thermotherapy (LITT). Untreated and coagulated (water bath, temperatures between 35 degrees C and 90 degrees C for 20 minutes.) samples of bovine liver tissue were examined using a Nd:YAG (lambda = 1064 nm) frequency-domain reflectance spectrometer. We determined the time integrated intensities (I(DC)) and the phase shifts (Phi) of the photon density waves after migration through the tissue. From these measured quantities, the time of flight (TOF) of the photons and the absorption coefficients of the samples were derived using the modified microscopic Beer-Lambert law. The absorption coefficients of the liver samples decreased significantly with the temperature in the range between 50 degrees C and 70 degrees C. At the same time, the TOF of the investigated photos was found increased indicating an increased scattering. The coagulation dynamics could be well described using the Arrhenius formalism with the activation energy of 106 kJ/mol and the frequency factor of 1.59 x 10(13)/second. Frequency-domain reflectance spectroscopy in combination with the modified microscopic Beer-Lambert (MBL) is suitable to measure heat induced changes in the absorption and scattering properties of bovine liver in vitro. The technique may be used to monitor the coagulation dynamics during local thermo-coagulation in vivo. Copyright 2005 Wiley-Liss, Inc.
ANFIS-based modelling for coagulant dosage in drinking water treatment plant: a case study.
Heddam, Salim; Bermad, Abdelmalek; Dechemi, Noureddine
2012-04-01
Coagulation is the most important stage in drinking water treatment processes for the maintenance of acceptable treated water quality and economic plant operation, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, pH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Traditionally, jar tests are used to determine the optimum coagulant dosage. However, this is expensive and time-consuming and does not enable responses to changes in raw water quality in real time. Modelling can be used to overcome these limitations. In this study, an Adaptive Neuro-Fuzzy Inference System (ANFIS) was used for modelling of coagulant dosage in drinking water treatment plant of Boudouaou, Algeria. Six on-line variables of raw water quality including turbidity, conductivity, temperature, dissolved oxygen, ultraviolet absorbance, and the pH of water, and alum dosage were used to build the coagulant dosage model. Two ANFIS-based Neuro-fuzzy systems are presented. The two Neuro-fuzzy systems are: (1) grid partition-based fuzzy inference system (FIS), named ANFIS-GRID, and (2) subtractive clustering based (FIS), named ANFIS-SUB. The low root mean square error and high correlation coefficient values were obtained with ANFIS-SUB method of a first-order Sugeno type inference. This study demonstrates that ANFIS-SUB outperforms ANFIS-GRID due to its simplicity in parameter selection and its fitness in the target problem.
Neurologic manifestations of electrolyte disturbances.
Riggs, Jack E
2002-02-01
Electrolyte disturbances occur commonly and are associated with a variety of characteristic neurologic manifestations involving both the central and peripheral nervous systems. Electrolyte disturbances are essentially always secondary processes. Effective management requires identification and treatment of the underlying primary disorder. Since neurological symptoms of electrolyte disorders are generally functional rather than structural, the neurologic manifestations of electrolyte disturbances are typically reversible. The neurologic manifestations of serum sodium, potassium, calcium, and magnesium disturbances are reviewed.
Process to remove rare earth from IFR electrolyte
Ackerman, John P.; Johnson, Terry R.
1994-01-01
The invention is a process for the removal of rare earths from molten chloride electrolyte salts used in the reprocessing of integrated fast reactor fuel (IFR). The process can be used either continuously during normal operation of the electrorefiner or as a batch process. The process consists of first separating the actinide values from the salt before purification by removal of the rare earths. After replacement of the actinides removed in the first step, the now-purified salt electrolyte has the same uranium and plutonium concentration and ratio as when the salt was removed from the electrorefiner.
Process to remove rare earth from IFR electrolyte
Ackerman, J.P.; Johnson, T.R.
1992-01-01
The invention is a process for the removal of rare earths from molten chloride electrolyte salts used in the reprocessing of integrated fast reactor fuel (IFR). The process can be used either continuously during normal operation of the electrorefiner or as a batch process. The process consists of first separating the actinide values from the salt before purification by removal of the rare earths. After replacement of the actinides removed in the first step, the now-purified salt electrolyte has the same uranium and plutonium concentration and ratio as when the salt was removed from the electrorefiner.
Process to remove rare earth from IFR electrolyte
Ackerman, J.P.; Johnson, T.R.
1994-08-09
The invention is a process for the removal of rare earths from molten chloride electrolyte salts used in the reprocessing of integrated fast reactor fuel (IFR). The process can be used either continuously during normal operation of the electrorefiner or as a batch process. The process consists of first separating the actinide values from the salt before purification by removal of the rare earths. After replacement of the actinides removed in the first step, the now-purified salt electrolyte has the same uranium and plutonium concentration and ratio as when the salt was removed from the electrorefiner. 1 fig.
Coagulation of grains in static and collapsing protostellar clouds
NASA Technical Reports Server (NTRS)
Weidenschilling, S. J.; Ruzmaikina, T. V.
1993-01-01
The wavelength dependence of extinction in the diffuse interstellar medium implies that it is produced by particles of dominant size of approximately 10(exp -5) cm. There is some indication that in the cores of dense molecular clouds, sub-micron grains can coagulate to form larger particles; this process is probably driven by turbulence. The most primitive meteorites (carbonaceous chondrites) are composed of particles with a bimodal size distribution with peaks near 1 micron (matrix) and 1 mm (chondrules). Models for chondrule formation that involve processing of presolar material by chemical reactions or through an accretion shock during infall assume that aggregates of the requisite mass could form before or during collapse. The effectiveness of coagulation during collapse has been disputed; it appears to depend on specific assumptions. The first results of detailed numerical modeling of spatial and temporal variations of particle sizes in presolar clouds, both static and collapsing, is reported in this article.
Pellets valorization of waste biomass harvested by coagulation of freshwater algae.
Cancela, Ángeles; Sánchez, Ángel; Álvarez, Xana; Jiménez, Alejandro; Ortiz, Luis; Valero, Enrique; Varela, Paloma
2016-03-01
There is a comparison of different coagulants: calcium chloride (20, 60, 120 and 180 mg/L); sodium alginate (10 and 20 mg/L) and tannins of Eucalyptus globulus bark (10 and 20 mg/L) in order to make the most of each method. The results show that 20 mg/L of tannin achieved a recovery efficiency of 95.35±1.16, sodium alginate 90.49±0.53 and 84.04±2.29 for calcium chloride. Taking into account the economic side of the coagulants, obtaining tannins is a profitable process. Bark is waste biomass obtained in the forestry process; therefore it does not involve extra costs. Finally, the feasibility of making pellets from harvested algae was studied, and the results suggest that waste biomass pellets may be used as fuel in boilers in a mixture <54% with other waste sources as Eucalyptus g. branches. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jung, Kyung-Won; Ahn, Kyu-Hong
2016-01-01
The present study is focused on the application of recovered coagulant (RC) by acidification from drinking water treatment residuals for both adjusting the initial pH and aiding coagulant in electrocoagulation. To do this, real cotton textile wastewater was used as a target pollutant, and decolorization and chemical oxygen demand (COD) removal efficiency were monitored. A preliminary test indicated that a stainless steel electrode combined with RC significantly accelerated decolorization and COD removal efficiencies, by about 52% and 56%, respectively, even at an operating time of 5 min. A single electrocoagulation system meanwhile requires at least 40 min to attain the similar removal performances. Subsequently, the interactive effect of three independent variables (applied voltage, initial pH, and reaction time) on the response variables (decolorization and COD removal) was evaluated, and these parameters were statistically optimized using the response surface methodology. Analysis of variance showed a high coefficient of determination values (decolorization, R(2) = 0.9925 and COD removal, R(2) = 0.9973) and satisfactory prediction second-order polynomial quadratic regression models. Average decolorization and COD removal of 89.52% and 94.14%, respectively, were achieved, corresponding to 97.8% and 98.1% of the predicted values under statistically optimized conditions. The results suggest that the RC effectively played a dual role of both adjusting the initial pH and aiding coagulant in the electrocoagulation process.
Recovery of mercury from mercury compounds via electrolytic methods
Grossman, Mark W.; George, William A.
1991-01-01
A process for electrolytically recovering mercury from mercury compounds is provided. In one embodiment, Hg is recovered from Hg.sub.2 Cl.sub.2 employing as the electrolyte solution a mixture of HCl and H.sub.2 O. In another embodiment, Hg is electrolytically recovered from HgO wherein the electrolyte solution is comprised of glacial acetic acid and H.sub.2 O. Also provided is an apparatus for producing isotopically enriched mercury compounds in a reactor and then transporting the dissolved compounds into an electrolytic cell where mercury ions are electrolytically reduced and elemental mercury recovered from the mercury compounds.
Recovery of mercury from mercury compounds via electrolytic methods
Grossman, Mark W.; George, William A.
1988-01-01
A process for electrolytically recovering mercury from mercury compounds is provided. In one embodiment, Hg is recovered from Hg.sub.2 Cl.sub.2 employing as the electrolyte solution a mixture of HCl and H.sub.2 O. In another embodiment, Hg is electrolytically recovered from HgO wherein the electrolyte solution is comprised of glacial acetic acid and H.sub.2 O. Also provided is an apparatus for producing isotopically enriched mercury compounds in a reactor and then transporting the dissolved compounds into an electrolytic cell where mercury ions are electrolytically reduced and elemental mercury recovered from the mercury compounds.
Recovery of mercury from mercury compounds via electrolytic methods
Grossman, Mark W.; George, William A.
1989-01-01
A process for electrolytically recovering mercury from mercury compounds is provided. In one embodiment, Hg is recovered from Hg.sub.2 Cl.sub.2 employing as the electrolyte solution a mixture of HCl and H.sub.2 O. In another embodiment, Hg is electrolytically recovered from HgO wherein the electrolyte solution is comprised of glacial acetic acid and H.sub.2 O. Also provided is an apparatus for producing isotopically enriched mercury compounds in a reactor and then transporting the dissolved compounds into an electrolytic cell where mercury ions are electrolytically reduced and elemental mercury recovered from the mercury compounds.
Poulsen, N A; Bertelsen, H P; Jensen, H B; Gustavsson, F; Glantz, M; Månsson, H Lindmark; Andrén, A; Paulsson, M; Bendixen, C; Buitenhuis, A J; Larsen, L B
2013-08-01
Substantial variation in milk coagulation properties has been observed among dairy cows. Consequently, raw milk from individual cows and breeds exhibits distinct coagulation capacities that potentially affect the technological properties and milk processing into cheese. This variation is largely influenced by protein composition, which is in turn affected by underlying genetic polymorphisms in the major milk proteins. In this study, we conducted a large screening on 3 major Scandinavian breeds to resolve the variation in milk coagulation traits and the frequency of milk with impaired coagulation properties (noncoagulation). In total, individual coagulation properties were measured on morning milk collected from 1,299 Danish Holstein (DH), Danish Jersey (DJ), and Swedish Red (SR) cows. The 3 breeds demonstrated notable interbreed differences in coagulation properties, with DJ cows exhibiting superior coagulation compared with the other 2 breeds. In addition, milk samples from 2% of DH and 16% of SR cows were classified as noncoagulating. Furthermore, the cows were genotyped for major genetic variants in the αS1- (CSN1S1), β- (CSN2), and κ-casein (CSN3) genes, revealing distinct differences in variant frequencies among breeds. Allele I of CSN2, which had not formerly been screened in such a high number of cows in these Scandinavian breeds, showed a frequency around 7% in DH and DJ, but was not detected in SR. Genetic polymorphisms were significantly associated with curd firming rate and rennet coagulation time. Thus, CSN1S1 C, CSN2 B, and CSN3 B positively affected milk coagulation, whereas CSN2 A(2), in particular, had a negative effect. In addition to the influence of individual casein genes, the effects of CSN1S1-CSN2-CSN3 composite genotypes were also examined, and revealed strong associations in all breeds, which more or less reflected the single gene results. Overall, milk coagulation is under the influence of additive genetic variation. Optimal milk for future cheese production can be ensured by monitoring the frequency of unfavorable variants and thus preventing an increase in the number of cows producing milk with impaired coagulation. Selective breeding for variants associated with superior milk coagulation can potentially increase raw milk quality and cheese yield in all 3 Scandinavian breeds. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Stable dye-sensitized solar cells based on a gel electrolyte with ethyl cellulose as the gelator
NASA Astrophysics Data System (ADS)
Vasei, Maryam; Tajabadi, Fariba; Jabbari, Ali; Taghavinia, Nima
2015-09-01
A simple gelating process is developed for the conventional acetonitrile-based electrolyte of dye solar cells, based on ethyl cellulose as the gelator. The electrolyte becomes quasi-solid-state upon addition of an ethanolic solution of ethyl cellulose to the conventional acetonitrile-based liquid electrolyte. The photovoltaic conversion efficiency with the new gel electrolyte is only slightly lower than with the liquid electrolyte, e.g., 6.5 % for liquid electrolyte versus 5.9 % for gel electrolyte with 5.8 wt% added ethyl cellulose. Electrolyte gelation has small effect on the ionic diffusion coefficient of iodide, and the devices are remarkably stable for at least 550 h under irradiation at 55 °C.
See, Kimberly A; Liu, Yao-Min; Ha, Yeyoung; Barile, Christopher J; Gewirth, Andrew A
2017-10-18
Magnesium batteries offer an opportunity to use naturally abundant Mg and achieve large volumetric capacities reaching over four times that of conventional Li-based intercalation anodes. High volumetric capacity is enabled by the use of a Mg metal anode in which charge is stored via electrodeposition and stripping processes, however, electrolytes that support efficient Mg electrodeposition and stripping are few and are often prepared from highly reactive compounds. One interesting electrolyte solution that supports Mg deposition and stripping without the use of highly reactive reagents is the magnesium aluminum chloride complex (MACC) electrolyte. The MACC exhibits high Coulombic efficiencies and low deposition overpotentials following an electrolytic conditioning protocol that stabilizes species necessary for such behavior. Here, we discuss the effect of the MgCl 2 and AlCl 3 concentrations on the deposition overpotential, current density, and the conditioning process. Higher concentrations of MACC exhibit enhanced Mg electrodeposition current density and much faster conditioning. An increase in the salt concentrations causes a shift in the complex equilibria involving both cations. The conditioning process is strongly dependent on the concentration suggesting that the electrolyte is activated through a change in speciation of electrolyte complexes and is not simply due to the annihilation of electrolyte impurities. Additionally, the presence of the [Mg 2 (μ-Cl) 3 ·6THF] + in the electrolyte solution is again confirmed through careful analysis of experimental Raman spectra coupled with simulation and direct observation of the complex in sonic spray ionization mass spectrometry. Importantly, we suggest that the ∼210 cm -1 mode commonly observed in the Raman spectra of many Mg electrolytes is indicative of the C 3v symmetric [Mg 2 (μ-Cl) 3 ·6THF] + . The 210 cm -1 mode is present in many electrolytes containing MgCl 2 , so its assignment is of broad interest to the Mg electrolyte community.
Solid oxide fuel cells with bi-layered electrolyte structure
NASA Astrophysics Data System (ADS)
Zhang, Xinge; Robertson, Mark; Decès-Petit, Cyrille; Xie, Yongsong; Hui, Rob; Qu, Wei; Kesler, Olivera; Maric, Radenka; Ghosh, Dave
In this work, we have developed solid oxide fuel cells with a bi-layered electrolyte of 2 μm SSZ and 4 μm SDC using tape casting, screen printing, and co-firing processes. The cell reached power densities of 0.54 W cm -2 at 650 °C and 0.85 W cm -2 at 700 °C, with open circuit voltage (OCV) values larger than 1.02 V. The electrical leaking between anode and cathode through an SDC electrolyte has been blocked in the bi-layered electrolyte structure. However, both the electrolyte resistance (R el) and electrode polarization resistance (R p,a+c) increased in comparison to cells with single-layered SDC electrolytes. The formation of a solid solution of (Ce, Zr)O 2- x during sintering process and the flaws in the bi-layered electrolyte structure seem to be the main causes for the increase in the R el value (0.32 Ω cm 2) at 650 °C, which is almost one order of magnitude higher than the calculated value.
Electrolytic recovery of reactor metal fuel
Miller, W.E.; Tomczuk, Z.
1994-09-20
A new electrolytic process and apparatus are provided using sodium, cerium or a similar metal in alloy or within a sodium beta or beta[double prime]-alumina sodium ion conductor to electrolytically displace each of the spent fuel metals except for cesium and strontium on a selective basis from the electrolyte to an inert metal cathode. Each of the metals can be deposited separately. An electrolytic transfer of spent fuel into the electrolyte includes a sodium or cerium salt in the electrolyte with sodium or cerium alloy being deposited on the cathode during the transfer of the metals from the spent fuel. The cathode with the deposit of sodium or cerium alloy is then shunted to an anode and the reverse transfer is carried out on a selective basis with each metal being deposited separately at the cathode. The result is that the sodium or cerium needed for the process is regenerated in the first step and no additional source of these reactants is required. 2 figs.
Electrolytic recovery of reactor metal fuel
Miller, W.E.; Tomczuk, Z.
1993-02-03
This invention is comprised of a new electrolytic process and apparatus using sodium, cerium or a similar metal in an alloy or within a sodium beta or beta-alumina sodium ion conductor to electrolytically displace each of the spent fuel metals except for Cesium and strontium on a selective basis from the electrolyte to an inert metal cathode. Each of the metals can be deposited separately. An electrolytic transfer of spent fuel into the electrolyte includes a sodium or cerium salt in the electrolyte with sodium or cerium alloy being deposited on the cathode during the transfer of the metals from the spent fuel. The cathode with the deposit of sodium or cerium alloy is then changed to an anode and the reverse transfer is carried out on a selective basis with each metal being deposited separately at the cathode. The result is that the sodium or cerium needed for the process is regenerated in the first step and no additional source of these reactants is required.
Electrolytic recovery of reactor metal fuel
Miller, William E.; Tomczuk, Zygmunt
1994-01-01
A new electrolytic process and apparatus are provided using sodium, cerium or a similar metal in alloy or within a sodium beta or beta"-alumina sodium ion conductor to electrolytically displace each of the spent fuel metals except for cesium and strontium on a selective basis from the electrolyte to an inert metal cathode. Each of the metals can be deposited separately. An electrolytic transfer of spent fuel into the electrolyte includes a sodium or cerium salt in the electrolyte with sodium or cerium alloy being deposited on the cathode during the transfer of the metals from the spent fuel. The cathode with the deposit of sodium or cerium alloy is then chanted to an anode and the reverse transfer is carried out on a selective basis with each metal being deposited separately at the cathode. The result is that the sodium or cerium needed for the process is regenerated in the first step and no additional source of these reactants is required.
Removal of Arsenic from Drinking Water by Adsorption and Coagulation
NASA Astrophysics Data System (ADS)
Zhang, M.; Sugita, H.; Hara, J.; Takahashi, S.
2013-12-01
Removal of arsenic from drinking water has been an important issue worldwide, which has attracted greater attentions in recent years especially for supplying safe drinking water in developing countries. Although many kinds of treatment approaches that are available or applicable both in principle and practice, such as adsorption, coagulation, membrane filtration, ion exchange, biological process, electrocoagulation and so on, the first 2 approaches (i.e., adsorption and coagulation) are most promising due to the low-cost, high-efficiency, simplicity of treating systems, and thus can be practically used in developing countries. In this study, a literature survey on water quality in Bangladesh was performed to understand the ranges of arsenic concentration and pH of groundwater in Bangladesh. A series of tests were then organized and performed to investigate the effects of arsenic concentration, arsenic forms, pH, chemical compositions of the materials used for adsorption and coagulation, particle size distribution and treatment time on quality of treated water. The experimental results obtained in the study illustrated that both adsorption and coagulation can be used to effectively reduce the concentrations of either arsenic (V) or arsenic (III) from the contaminated water. Coagulation of arsenic with a magnesium-based material developed in this study can be very effective to remove arsenic, especially arsenic (V), from contaminated water with a concentration of 10 ppm to an undetectable level of 0.002 ppm by ICP analyses. Compared to arsenic (III), arsenic (V) is easier to be removed. The materials used for adsorption and coagulation in this study can remove arsenic (V) up to 9 mg/g and 6 mg/g, and arsenic (III) up to 4 mg/g and 3 mg/g, respectively, depending on test conditions and compositions of the materials being used. The control of pH during treatment can be a challenging technical issue for developing both adsorbent and coagulant. Keywords: Water Treatment, Arsenic, Adsorption, Coagulation, Drinking Water, Bangladesh
Electrolytic trapping of iodine from process gas streams
Horner, Donald E.; Mailen, James C.; Posey, Franz A.
1977-01-25
A method for removing molecular, inorganic, and organic forms of iodine from process gas streams comprises the electrolytic oxidation of iodine in the presence of cobalt-III ions. The gas stream is passed through the anode compartment of a partitioned electrolytic cell having a nitric acid anolyte containing a catalytic amount of cobalt to cause the oxidation of effluent iodine species to aqueous soluble species.
Does Bicarbonate Correct Coagulation Function Impaired by Acidosis in Swine?
2006-07-01
requires sufficient fibrinogen available in the circulation . At any time, fibrinogen availabil- Fig. 4. Thrombin generation kinetics at baseline (T0... circulation can potentially impact physiologic function. As the precursor in the coagulation process, fibrinogen is primarily involved in maintaining...with different proteins. It is also possible that following acidosis insult, some of the albumin loss from the circulation was compensated for by
Costs of examinations performed in a hospital laboratory in Chile.
Andrade, Germán Lobos; Palma, Carolina Salas
2018-01-01
To determine the total average costs related to laboratory examinations performed in a hospital laboratory in Chile. Retrospective study with data from July 2014 to June 2015. 92 examinations classified in ten groups were selected according to the analysis methodology. The costs were estimated as the sum of direct and indirect laboratory costs and indirect institutional factors. The average values obtained for the costs according to examination group (in USD) were: 1.79 (clinical chemistry), 10.21 (immunoassay techniques), 13.27 (coagulation), 26.06 (high-performance liquid chromatography), 21.2 (immunological), 3.85 (gases and electrolytes), 156.48 (cytogenetic), 1.38 (urine), 4.02 (automated hematological), 4.93 (manual hematological). The value, or service fee, returned to public institutions who perform laboratory services does not adequately reflect the true total average production costs of examinations.
Usage of Neural Network to Predict Aluminium Oxide Layer Thickness
Michal, Peter; Vagaská, Alena; Gombár, Miroslav; Kmec, Ján; Spišák, Emil; Kučerka, Daniel
2015-01-01
This paper shows an influence of chemical composition of used electrolyte, such as amount of sulphuric acid in electrolyte, amount of aluminium cations in electrolyte and amount of oxalic acid in electrolyte, and operating parameters of process of anodic oxidation of aluminium such as the temperature of electrolyte, anodizing time, and voltage applied during anodizing process. The paper shows the influence of those parameters on the resulting thickness of aluminium oxide layer. The impact of these variables is shown by using central composite design of experiment for six factors (amount of sulphuric acid, amount of oxalic acid, amount of aluminium cations, electrolyte temperature, anodizing time, and applied voltage) and by usage of the cubic neural unit with Levenberg-Marquardt algorithm during the results evaluation. The paper also deals with current densities of 1 A·dm−2 and 3 A·dm−2 for creating aluminium oxide layer. PMID:25922850
Usage of neural network to predict aluminium oxide layer thickness.
Michal, Peter; Vagaská, Alena; Gombár, Miroslav; Kmec, Ján; Spišák, Emil; Kučerka, Daniel
2015-01-01
This paper shows an influence of chemical composition of used electrolyte, such as amount of sulphuric acid in electrolyte, amount of aluminium cations in electrolyte and amount of oxalic acid in electrolyte, and operating parameters of process of anodic oxidation of aluminium such as the temperature of electrolyte, anodizing time, and voltage applied during anodizing process. The paper shows the influence of those parameters on the resulting thickness of aluminium oxide layer. The impact of these variables is shown by using central composite design of experiment for six factors (amount of sulphuric acid, amount of oxalic acid, amount of aluminium cations, electrolyte temperature, anodizing time, and applied voltage) and by usage of the cubic neural unit with Levenberg-Marquardt algorithm during the results evaluation. The paper also deals with current densities of 1 A · dm(-2) and 3 A · dm(-2) for creating aluminium oxide layer.
Qi, Jing; Lan, Huachun; Liu, Ruiping; Liu, Huijuan; Qu, Jiuhui
2018-06-15
The coagulation/flocculation/flotation (C/F/F) process is becoming a popular method for algae-laden water treatment. However, the efficiency of flotation is highly dependent on the ability of the preceding coagulation/flocculation process to form flocculated algae flocs. This study aims to improve the Microcystis aeruginosa flotation efficiency from algae cell and organic matter aspects by applying Fe(II)-regulated pretreatment enhanced Al coagulation process. The ability of the C/F/F process to remove cyanobacterial cells can be enhanced from 8% to 99% at a Fe(II) dose of 30 μM. The Al dose needed can be reduced by more than half while achieving successful flotation. The introduced Fe(II) after KMnO 4 can not only realize moderate pre-oxidation of cyanobacterial cells, but also form in-situ Fe(III). The DOC value can also be decreased significantly due to the formation of in-situ Fe(III), which is more efficient in dissolved organic matter (DOM) removal compared with pre-formed Fe(III). In addition, the gradually hydrolyzed in-situ Fe(III) can facilitate the hydrolysis of Al as a dual-coagulant and promote the clustering and cross-linking of Al hydrolyzates, which can enhance the formation of size-controlled algae flocs. Finally, the size-controlled algae flocs can be effectively floated by the bubbles released in the flotation process due to the efficient collision and attachment between flocs and bubbles. Therefore, the efficient flotation of algae cell and organic matter can be realized by the Fe(II) regulated moderate pre-oxidation of M. aeruginosa and formation of size-controlled algae flocs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ellery, Paul E. R.; Maroney, Susan A.; Cooley, Brian C.; Luyendyk, James P.; Zogg, Mark; Weiler, Hartmut
2015-01-01
Tissue factor pathway inhibitor (TFPI) is a critical anticoagulant protein present in endothelium and platelets. Mice lacking TFPI (Tfpi−/−) die in utero from disseminated intravascular coagulation. They are rescued by concomitant tissue factor (TF) deficiency, demonstrating that TFPI modulates TF function in vivo. Recent studies have found TFPI inhibits prothrombinase activity during the initiation of coagulation and limits platelet accumulation during thrombus formation, implicating TFPI in modulating platelet procoagulant activity. To examine whether altered platelet function would compensate for the lack of TFPI and rescue TFPI-null embryonic lethality, Tfpi+/− mice lacking the platelet thrombin receptor, protease activated receptor 4 (PAR4; Par4−/−), or its coreceptor, PAR3, were mated. PAR3 deficiency did not rescue Tfpi−/− embryos, but >40% of expected Tfpi−/−:Par4−/− offspring survived to adulthood. Adult Tfpi−/−:Par4−/− mice did not exhibit overt thrombosis. However, they had focal sterile inflammation with fibrin(ogen) deposition in the liver and elevated plasma thrombin-antithrombin complexes, indicating activation of coagulation at baseline. Tfpi−/−:Par4−/− mice have platelet and fibrin accumulation similar to Par4−/− mice following venous electrolytic injury but were more susceptible than Par4−/− mice to TF-induced pulmonary embolism. In addition, ∼30% of the Tfpi−/−:Par4−/− mice were born with short tails. Tfpi−/−:Par4−/− mice are the first adult mice described that lack TFPI with unaltered TF. They demonstrate that TFPI physiologically modulates thrombin-dependent platelet activation in a manner that is required for successful embryonic development and identify a role for TFPI in dampening intravascular procoagulant stimuli that lead to thrombin generation, even in the absence of thrombin-mediated platelet activation. PMID:25954015
Recovery of mercury from mercury compounds via electrolytic methods
Grossman, M.W.; George, W.A.
1991-06-18
A process for electrolytically recovering mercury from mercury compounds is provided. In one embodiment, Hg is recovered from Hg[sub 2]Cl[sub 2] employing as the electrolyte solution a mixture of HCl and H[sub 2]O. In another embodiment, Hg is electrolytically recovered from HgO wherein the electrolyte solution is comprised of glacial acetic acid and H[sub 2]O. Also provided is an apparatus for producing isotopically enriched mercury compounds in a reactor and then transporting the dissolved compounds into an electrolytic cell where mercury ions are electrolytically reduced and elemental mercury recovered from the mercury compounds. 3 figures.
Recovery of mercury from mercury compounds via electrolytic methods
Grossman, M.W.; George, W.A.
1989-11-07
A process for electrolytically recovering mercury from mercury compounds is provided. In one embodiment, Hg is recovered from Hg[sub 2]Cl[sub 2] employing as the electrolyte solution a mixture of HCl and H[sub 2]O. In another embodiment, Hg is electrolytically recovered from HgO wherein the electrolyte solution is comprised of glacial acetic acid and H[sub 2]O. Also provided is an apparatus for producing isotopically enriched mercury compounds in a reactor and then transporting the dissolved compounds into an electrolytic cell where mercury ions are electrolytically reduced and elemental mercury recovered from the mercury compounds. 3 figs.
Combination of an electrolytic pretreatment unit with secondary water reclamation processes
NASA Technical Reports Server (NTRS)
Wells, G. W.; Bonura, M. S.
1973-01-01
The design and fabrication of a flight concept prototype electrolytic pretreatment unit (EPU) and of a contractor-furnished air evaporation unit (AEU) are described. The integrated EPU and AEU potable water recovery system is referred to as the Electrovap and is capable of processing the urine and flush water of a six-man crew. Results of a five-day performance verification test of the Electrovap system are presented and plans are included for the extended testing of the Electrovap to produce data applicable to the combination of electrolytic pretreatment with most final potable water recovery systems. Plans are also presented for a program to define the design requirements for combining the electrolytic pretreatment unit with a reverse osmosis final processing unit.
Metallization pattern on solid electrolyte or porous support of sodium battery process
Kim, Jin Yong; Li, Guosheng; Lu, Xiaochuan; Sprenkle, Vincent L.; Lemmon, John P.
2016-05-31
A new battery configuration and process are detailed. The battery cell includes a solid electrolyte configured with an engineered metallization layer that distributes sodium across the surface of the electrolyte extending the active area of the cathode in contact with the anode during operation. The metallization layer enhances performance, efficiency, and capacity of sodium batteries at intermediate temperatures at or below about 200.degree. C.
Proteins, Platelets, and Blood Coagulation at Biomaterial Interfaces
Xu, Li-Chong; Bauer, James; Siedlecki, Christopher A.
2015-01-01
Blood coagulation and platelet adhesion remain major impediments to the use of biomaterials in implantable medical devices. There is still significant controversy and question in the field regarding the role that surfaces play in this process. This manuscript addresses this topic area and reports on state of the art in the field. Particular emphasis is placed on the subject of surface engineering and surface measurements that allow for control and observation of surface-mediated biological responses in blood and test solutions. Appropriate use of surface texturing and chemical patterning methodologies allow for reduction of both blood coagulation and platelet adhesion, and new methods of surface interrogation at high resolution allow for measurement of the relevant biological factors. PMID:25448722
[Endothelial microparticles (EMP) in physiology and pathology].
Sierko, Ewa; Sokół, Monika; Wojtukiewicz, Marek Z
2015-08-18
Endothelial microparticles (EMP) are released from endothelial cells (ECs) in the process of activation and/or apoptosis. They harbor adhesive molecules, enzymes, receptors and cytoplasmic structures and express a wide range of various constitutive antigens, typical for ECs, at their surface. Under physiological conditions the concentration of EMP in the blood is clinically insignificant. However, it was reported that under pathological conditions EMP concentration in the blood might slightly increase and contribute to blood coagulation, angiogenesis and inflammation. It has been shown that EMP directly and indirectly contribute to the activation of blood coagulation. Endothelial microparticles directly participate in blood coagulation through their surface tissue factor (TF) - a major initiator of blood coagulation. Furthermore, EMP exhibit procoagulant potential via expression of negatively charged phospholipids at their surface, which may promote assembly of coagulation enzymes (TF/VII, tenases and prothrombinase complexes), leading to thrombus formation. In addition, they provide a binding surface for coagulation factors: IXa, VIII, Va and IIa. Moreover, it is possible that EMP transfer TF from TF-bearing EMP to activated platelets and monocytes by binding them through adhesion molecules. Also, EMP express von Willebrand factor, which may facilitate platelet aggregation. Apart from their procoagulant properties, it was demonstrated that EMP may express adhesive molecules and metalloproteinases (MMP-2, MMP-9) at their surface and release growth factors, which may contribute to angiogenesis. Additionally, surface presence of C3 and C4 - components of the classical pathway - suggests pro-inflammatory properties of these structures. This article contains a summary of available data on the biology and pathophysiology of endothelial microparticles and their potential role in blood coagulation, angiogenesis and inflammation.
Coagulation factor Xa drives tumor cells into apoptosis through BH3-only protein Bim up-regulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borensztajn, Keren S.; Bijlsma, Maarten F.; Groot, Angelique P.
2007-07-15
Coagulation Factor (F)Xa is a serine protease that plays a crucial role during blood coagulation by converting prothrombin into active thrombin. Recently, however, it emerged that besides this role in coagulation, FXa induces intracellular signaling leading to different cellular effects. Here, we show that coagulation factor (F)Xa drives tumor cells of epithelial origin, but not endothelial cells or monocytes, into apoptosis, whereas it even enhances fibroblast survival. FXa signals through the protease activated receptor (PAR)-1 to activate extracellular-signal regulated kinase (ERK) 1/2 and p38. This activation is associated with phosphorylation of the transcription factor CREB, and in tumor cells withmore » up-regulation of the BH3-only pro-apoptotic protein Bim, leading to caspase-3 cleavage, the main hallmark of apoptosis. Transfection of tumor cells with dominant negative forms of CREB or siRNA for either PAR-1, Bim, ERK1 and/or p38 inhibited the pro-apoptotic effect of FXa. In fibroblasts, FXa-induced PAR-1 activation leads to down-regulation of Bim and pre-treatment with PAR-1 or Bim siRNA abolishes proliferation. We thus provide evidence that beyond its role in blood coagulation, FXa plays a key role in cellular processes in which Bim is the central player in determining cell survival.« less
López-Maldonado, E A; Oropeza-Guzman, M T; Jurado-Baizaval, J L; Ochoa-Terán, A
2014-08-30
Based on the polyelectrolyte-contaminant physical and chemical interactions at the molecular level, this article analyzed and discussed the coagulation-flocculation and chemical precipitation processes in order to improve their efficiency. Bench experiments indicate that water pH, polyelectrolyte (PE) dosing strategy and cationic polyelectrolyte addition are key parameters for the stability of metal-PE complexes. The coagulation-flocculation mechanism is proposed based on zeta potential (ζ) measurement as the criteria to define the electrostatic interaction between pollutants and coagulant-flocculant agents. Polyelectrolyte and wastewater dispersions are exposed to an electrophoretic effect to determine ζ. Finally, zeta potential values are compared at pH 9, suggesting the optimum coagulant dose at 162mg/L polydadmac and 67mg/L of flocculant, since a complete removal of TSS and turbidity is achieved. Based on the concentration of heavy metals (0.931mg/L Sn, 0.7mg/L Fe and 0.63mg/L Pb), treated water met the Mexican maximum permissible limits. In addition, the treated water has 45mg O2/L chemical oxygen demand (COD) and 45mg C/L total organic carbon (TOC). The coagulation-flocculation mechanism is proposed taking into account both: zeta potential (ζ)-pH measurement and chemical affinity, as the criteria to define the electrostatic and chemical interaction between pollutants and polyelectrolytes. Copyright © 2014 Elsevier B.V. All rights reserved.
Shen, Feng; Pompano, Rebecca R.; Kastrup, Christian J.; Ismagilov, Rustem F.
2009-01-01
Abstract This study shows that environmental confinement strongly affects the activation of nonlinear reaction networks, such as blood coagulation (clotting), by small quantities of activators. Blood coagulation is sensitive to the local concentration of soluble activators, initiating only when the activators surpass a threshold concentration, and therefore is regulated by mass transport phenomena such as flow and diffusion. Here, diffusion was limited by decreasing the size of microfluidic chambers, and it was found that microparticles carrying either the classical stimulus, tissue factor, or a bacterial stimulus, Bacillus cereus, initiated coagulation of human platelet-poor plasma only when confined. A simple analytical argument and numerical model were used to describe the mechanism for this phenomenon: confinement causes diffusible activators to accumulate locally and surpass the threshold concentration. To interpret the results, a dimensionless confinement number, Cn, was used to describe whether a stimulus was confined, and a Damköhler number, Da2, was used to describe whether a subthreshold stimulus could initiate coagulation. In the context of initiation of coagulation by bacteria, this mechanism can be thought of as “diffusion acting”, which is distinct from “diffusion sensing”. The ability of confinement and diffusion acting to change the outcome of coagulation suggests that confinement should also regulate other biological “on” and “off” processes that are controlled by thresholds. PMID:19843446
Pei, Haiyan; Jin, Yan; Xu, Hangzhou; Ma, Chunxia; Sun, Jiongming; Li, Hongmin
2017-10-19
In this study, low-cost and non-polluting quartz sand was respectively mixed with AlCl 3 , FeCl 3 and PAFC to synergistically remove Microcystis aeruginosa. Results showed that quartz sand could markedly increase the algae removal efficiency and decrease the coagulant doses. The increase of removal efficiency with AlCl 3 and FeCl 3 was only due to the enhancement of floc density by the quartz sand. However, the removal efficiency with PAFC was increased not only by the enhanced floc density, but also by the enlarged floc size. Flocs from 50 mg/L sand addition were larger than that with other sand doses, which was on account of the appropriate enhancement of collision efficiency at this dose. After coagulation, the extracellular organic matter (EOM) and microcystins (MCs) in system with quartz sand was remarkably reduced. That's because quartz sand can enhance the coagulation so as to improve capping the EOM and MCs in flocs during coagulation process. Owing to 200 mg/L quartz sand could damage the cell's membrane during coagulation proces, algal cells in the system lysed two days earlier than with 50 mg/L sand during flocs storage. In addition, cells with PAFC incurred relatively moderate cellular oxidative damage and could remain intact for longer time.
Polymeric electrolytes based on hydrosilyation reactions
Kerr, John Borland [Oakland, CA; Wang, Shanger [Fairfield, CA; Hou, Jun [Painted Post, NY; Sloop, Steven Edward [Berkeley, CA; Han, Yong Bong [Berkeley, CA; Liu, Gao [Oakland, CA
2006-09-05
New polymer electrolytes were prepared by in situ cross-linking of allyl functional polymers based on hydrosilation reaction using a multifunctional silane cross-linker and an organoplatinum catalyst. The new cross-linked electrolytes are insoluble in organic solvent and show much better mechanical strength. In addition, the processability of the polymer electrolyte is maintained since the casting is finished well before the gel formation.
NASA Astrophysics Data System (ADS)
Séquaris, J.-M.; Lewandowski, H.; Vereecken, H.
Organic matter (OM) in soils plays an important role, i.e., in maintaining soil structure or as source of nutrients. OM is mainly adsorbed at the surface of clay minerals and oxides and remains mostly immobile. However, mobile OM in dissolved form (DOM) or associated with water dispersible colloids (WDC) in soil water may influence trans- port of pollutants. The goal of this study is to compare 5 typical German agricultural soils in terms of distribution and quality of OM in the top soil (0-15 cm). The present report focuses on the physicochemical characterization of potential mobile OM so- lutions obtained after physical fractionation of soil materials based on sedimentation after a prolonged shaking in water or electrolyte solutions. Three soil fractions dif- fering in particle size were separated in function of sedimentation time: a colloidal fraction: < 2 ţm; a microaggregate fraction: 2-20 ţm and a sediment fraction: > 20 ţm. The soil electrolyte phase containing the DOM fraction was obtained by a high-speed centrifugation of the colloidal phase. After a water or low electrolyte concentration (« 1 mM Ca2+) extraction, it can be shown that the mobile fraction of OM or OC (organic carbon) is distributed between the colloidal and the electrolyte phases in a concentration ratio range of 10-40 to 1. A less mobile OC fraction is associated with the microaggregate fraction while immobile OC remains adsorbed in the sediment fraction. An increasing OC and total-N content with diminishing particle-size of soil (colloidal and microaggregate fractions) has been confirmed. A higher OC input due to special soil management is sensitively detected in fractions with a greater particle size (sediment fraction). Increasing the Ca2+ concentration up to 10 mM during the water extraction diminishes the DOC concentration by an average factor of 3 while the OC associated with the dispersed colloids (OCWDC) vanished almost completely. Thus, a critical coagulation concentration of about 1-2 mM Ca2+ can be estimated which increases the stability of soil aggregates in water. Different titration, electrokinetic and spectroscopic methods were applied to characterize the colloidal and electrolyte phases. These techniques provide information on the physicochemical heterogeneity of mobile OM from various agricultural soils.
Li 2OHCl crystalline electrolyte for stable metallic lithium anodes
Hood, Zachary D.; Wang, Hui; Samuthira Pandian, Amaresh; ...
2016-01-22
In a classic example of stability from instability, we show that Li 2OHCl solid electrolyte forms a stable solid electrolyte interface (SEI) with metallic lithium anode. The Li 2OHCl solid electrolyte can be readily achieved through simple mixing of air-stable LiOH and LiCl precursors with a mild processing temperature under 400 °C. Additionally, we show that continuous, dense Li 2OHCl membranes can be fabricated at temperatures less than 400 °C, standing in great contrast to current processing temperatures of over 1600 °C for most oxide-based solid electrolytes. The ionic conductivity and Arrhenius activation energy were explored for the LiOH-LiCl systemmore » of crystalline solid electrolytes where Li 2OHCl with increased crystal defects was found to have the highest ionic conductivity and reasonable Arrhenius activation energy. The Li 2OHCl solid electrolyte displays stability against metallic lithium, even in extreme conditions past the melting point of lithium metal. Furthermore, to understand this excellent stability, we show that SEI formation is critical in stabilizing the interface between metallic lithium and the Li 2OHCl solid electrolyte.« less
Heteroaggregation of Silver Nanoparticles with Clay Minerals in Aqueous System
NASA Astrophysics Data System (ADS)
Liu, J.; Burrow, E.; Hwang, Y.; Lenhart, J.
2013-12-01
Nanoparticles are increasingly being used in industrial processes and consumer products that exploit their beneficial properties and improve our daily lives. Nevertheless, they also attract attention when released into natural environment due to their potential for causing adverse effects. The fate and transport of nanoparticles in aqueous systems have been the focus of intense study. However, their interactions with other natural particles have received only limited attention. Clay minerals are ubiquitous in most aquatic systems and their variably charged surfaces can act as deposition sites that can alter the fate and transport of nanoparticles in natural aqueous environments. In this study, we investigated the homoaggregation of silver nanoparticles with different coating layers and their heteroaggregation behavior with clay minerals (illite, kaolinite, montmorillonite) in neutral pH solutions. Silver nanoparticles with a nominal diameter of 80 nm were synthesized with three different surface coating layers: uncoated, citrate-coated and Tween-coated. Illite (IMt-2), kaolinite (KGa-2), and montmorillonite (SWy-2) were purchased from the Clay Mineral Society (Indiana) and pretreated to obtain monocationic (Na-clay) and dicationic (Ca-clay) suspensions before the experiments. The change in hydrodynamic diameter as a function of time was monitored using dynamic light scattering (DLS) measurements in order to evaluate early stage aggregation as a function of electrolyte concentration in both the homo- and heteroaggregation scenarios. A shift in the critical coagulation concentration (CCC) values to lower electrolyte concentrations was observed in binary systems, compared to single silver nanoparticle and clay systems. The results also suggest more rapid aggregation in binary system during the early aggregation stage when compared to the single-particle systems. The behavior of citrate-coated silver nanoparticles was similar to that of the bare particles, while the Tween-coated silver nanoparticles showed high stability in both single and binary systems. There were no significant differences in early stage aggregation kinetics observed inthe Na-clay-nanoparticle or Ca-clay-nanoparticle systems, which suggested that the CCC values of the single Na- or Ca-clay suspensions depend only on the electrolyte concentration, not the original cations on the clay surface. These results provide a basic idea for understanding the heteroaggregation of different silver nanoparticles and clays, which can be utilized in further study of fate and transport of engineered nanoparticles in natural aqueous system.
Aggregation Kinetics of Diesel Soot Nanoparticles in Wet Environments.
Chen, Chengyu; Huang, Weilin
2017-02-21
Soot produced during incomplete combustion consists mainly of carbonaceous nanoparticles (NPs) with severe adverse environmental and health effects, and its environmental fate and transport are largely controlled by aggregation. In this study, we examined the aggregation behavior for diesel soot NPs under aqueous condition in an effort to elucidate the fundamental processes that govern soot particle-particle interactions in wet environments such as rain droplets or surface aquatic systems. The influence of electrolytes and aqueous pH on colloidal stability of these NPs was investigated by measuring their aggregation kinetics in different aqueous solution chemistries. The results showed that the NPs had negatively charged surfaces and exhibited both reaction- and diffusion-limited aggregation regimes with rates depended upon solution chemistry. The aggregation kinetics data were in good agreement with the classic Derjaguin-Landau-Verwey-Overbeek (DLVO) theory. The critical coagulation concentrations (CCC) were quantified and the Hamaker constant was derived for the soot (1.4 × 10 -20 J) using the colloidal chemistry approach. The study indicated that, depending upon local aqueous chemistry, single soot NPs could remain stable against self-aggregation in typical freshwater environments and in neutral cloud droplets but are likely to aggregate under salty (e.g., estuaries) or acidic (e.g., acid rain droplets) aquatic conditions or both.
Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.
Chen, Liming; Chen, Yu
2015-01-01
Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.
Ebrahimi, Afshin; Amin, Mohammad Mehdi; Pourzamani, Hamidreza; Hajizadeh, Yaghoub; Mahvi, Amir Hossein; Mahdavi, Mokhtar; Rad, Mohammad Hassan Rabie
2017-08-01
In this study, the reclamation of clean water from spent filter backwash water (SFBW) was investigated through pilot-scale experiments. The pilot plant consisted of pre-sedimentation, coagulation, flocculation, clarification, and ultrafiltration (UF). Two coagulants of PAFCl and FeCl 3 were investigated with respect to their performance on treated SFBW quality and UF membrane fouling. At the optimum dose of PAFCl and FeCl 3 turbidity removal of 99.6 and 99.4% was attained, respectively. PAFCl resulted in an optimum UV 254 , TOC, and DOC removal of 80, 83.6, and 72.7%, respectively, and FeCl 3 caused the removal of those parameters by 76.7, 80.9, and 65.9%, respectively. PAFCl removed hydrophilic and transphilic constituent better than FeCl 3 , but FeCl 3 had, to some extent, higher affinities to a hydrophobic fraction. It was concluded that PAFCl showed a better coagulation performance in most cases and caused a lower membrane fouling rate compared to FeCl 3 . Finally, the treated SFBW with both coagulant-UF systems met the drinking water standards.
Influence of the Mixing Energy Consumption Affecting Coagulation and Floc Aggregation.
Vadasarukkai, Yamuna S; Gagnon, Graham A
2017-03-21
The operational significance of energy-intensive rapid mixing processes remains unaddressed in coagulation and flocculation of insoluble precipitates (flocs), which play an important role in the removal of impurities from drinking water supplies. In this study, the influence of rapid mixing and associated mixing energy on floc aggregation was examined for a surface water source characterized by a high fraction of aquatic humic matter. Infrared spectral analyses showed that the colloidal complexes resulting from ligand exchange between iron and dissolved natural organic matter (DOM) were not substantially influenced by the mixing energy input. This signified that DOM removal by coagulation can be achieved at lower mixing intensity, thereby reducing energy consumption. In contrast, macroscopic investigations showed the coagulation mixing energy affected floc size distributions during the slow mixing stage in flocculation and, to some extent, their settling characteristics. The results from analysis of floc properties clearly showed that more mixing energy was expended than necessary in coagulation, which is typically designed at a high mixing intensity range of 600-1000 s -1 in treatment plants. The key findings from this study have practical implications to water utilities to strategically meet water quality goals while reducing energy demands.
Ke, Zhigang; Huang, Qing
2016-01-01
Although blood coagulation facilitated by non-thermal plasma has been reported several years ago, the insight to the involved mechanisms is still rather limited. In this work, we report our discovery of a new mechanism for the haem-promoted blood-coagulation caused by non-thermal plasma treatment. The reason for the haem role is due to that its oxidized form, namely, hematin, can promote the dityrosine cross-linking of fibrinogen, the most important coagulation protein, to form a membrane-like layer on the surface of the treated blood with plasma exposure. Both haem and non-thermal-plasma generated hydrogen peroxide are requisite for the cross-linking process. We confirmed that fibrinogen can coordinate with the haem iron to form a protein-haem complex which shows pseudo-peroxidase activity, and in the presence of hydrogen peroxide, the complex can induce the dityrosine formation between fibrinogen molecules, leading to the fibrin network necessary for the blood coagulation. Understanding of such an underlying mechanism can be useful to guide more efficient application of non-thermal plasma in the management of hemostasis, thrombosis and etc. PMID:27229173
Soluble Proteins Form Film by the Treatment of Low Temperature Plasma
NASA Astrophysics Data System (ADS)
Ikehara, Sanae; Sakakita, Hajime; Ishikawa, Kenji; Akimoto, Yoshihiro; Nakanishi, Hayao; Shimizu, Nobuyuki; Hori, Masaru; Ikehara, Yuzuru
2015-09-01
It has been pointed out that low temperature plasma in atmosphere was feasible to use for hemostasis without heat injury. Indeed, earlier studies demonstrated that low temperature plasma played an important role to stimulate platelets to aggregate and turned on the proteolytic activities of coagulation factors, resulting in the acceleration of the natural blood coagulation process. On the other hands, our developed equips could immediately form clots upon the contact with plasma flair, while the histological appearance was different from natural coagulation. Based on these findings in formed clots, we sought to determine if plasma flair supplied by our devices was capable of forming film using a series of soluble proteins Following plasma treatment, films were formed from bovine serum albumin, and the other plasma proteins at physiological concentration. Analysis of trans-electron microscope demonstrated that plasma treatment generated small protein particles and made them fuse to be larger aggregations The combined results demonstrated that plasma are capable of aggregating soluble proteins and that platelets and coagulation factors are not necessary for plasma induced blood coagulation. Supported in part by Grants-in-Aid for Scientific Research on Priority Area (21590454, 24590498, and 24108006 to Y. I.).
Process for electrochemically gasifying coal using electromagnetism
Botts, Thomas E.; Powell, James R.
1987-01-01
A process for electrochemically gasifying coal by establishing a flowing stream of coal particulate slurry, electrolyte and electrode members through a transverse magnetic field that has sufficient strength to polarize the electrode members, thereby causing them to operate in combination with the electrolyte to electrochemically reduce the coal particulate in the slurry. Such electrochemical reduction of the coal produces hydrogen and carbon dioxide at opposite ends of the polarized electrode members. Gas collection means are operated in conjunction with the process to collect the evolved gases as they rise from the slurry and electrolyte solution.
Park, Taejun; Ampunan, Vanvimol; Maeng, Sungkyu; Chung, Eunhyea
2017-01-01
Phosphorus removal has been studied for decades to reduce the environmental impact of phosphorus in natural waterbodies. Slag has been applied for the phosphorus removal by several mechanisms. In this study, sodium hydroxide coating was applied on the slag surface to enhance the efficiency of precipitation-coagulation process. In the batch test, it was found that the capacity of the slag to maintain high pH decreases with increasing its exposure time to the aqueous solution. In the column test, the coarse-grained coated slag showed higher phosphorus removal efficiency than the fine-grained uncoated slag. The coated slag maintained pH higher than uncoated slag and, accordingly, the removal efficiency of phosphorus was higher. Especially, when pH was less than 8, the removal efficiency decreased significantly. However, coated slag provided an excess amount of aluminum and sodium. Thus, a return process to reuse aluminum and sodium as a coagulant was introduced. The return process yields longer lifespan of slag with higher phosphorus removal and lower concentration of cations in the effluent. With the return process, the phosphorus removal efficiency was kept higher than 60% until 150 bed volumes; meanwhile, the efficiency without return process became lower than 60% at 25 bed volumes. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Arsenic removal by coagulation process and the field expanding experiments for Yangzonghai Lake].
Chen, Jing; Zhang, Shu; Yang, Xiang-jun; Huang, Zhang-jie; Wang, Shi-xiong; Wang, Chong; Wei, Qun-yan; Zhang, Gen-lin; Xiao, Jun
2015-01-01
Yangzonghai Lake is the third largest plateau lake in Yunnan province. In June 2008, arsenic contamination was detected in Yangzonghai Lake and the water quality worsens dramatically from standard grade II to worse than grade V. Since Yongzonghai Lake is so large with the area of 31 km2 and the storage capacity of 6.04 x 10(8) m3, those pretreatment operations of the traditional arsenic removal methods, such as pre oxidation, adjusting pH value, are not applicable. In this study, a facile remediation strategy for arsenic removal by coagulation process, in which ferric chloride was directly sprayed into the contaminated water without any pretreatment, was reported. The results showed that the arsenic removal percentage was up to 95.1%-96.7% for 50 L raw water with reagent dosage of 1.62-3.20 mg x L(-1). Furthermore, the pH value of the lake kept constant in the coagulation process, which was beneficial for fish survival. Re-dissolved arsenic from precipitation was not detected in 954 days. The strategy of ferric chloride coagulation were applied to field experiments for lake water with volumes of 1 x 10(4) m3 and 25 x 10(4) m3, in which arsenic was also removed effectively. The reported strategy was of great advantage for simple operation, low cost and ecological safety, therefore it provides a representative example for arsenic contamination treatment of large lake.
De Feo, G; Galasso, M; Landi, R; Donnarumma, A; De Gisi, S
2013-01-01
CAPS is the acronym for chemically assisted primary sedimentation, which consists of adding chemicals to raw urban wastewater to increase the efficacy of coagulation, flocculation and sedimentation. The principal benefits of CAPS are: upgrading of urban wastewater treatment plants; increasing efficacy of primary sedimentation; and the major production of energy from the anaerobic digestion of primary sludge. Metal coagulants are usually used because they are both effective and cheap, but they can cause damage to the biological processes of anaerobic digestion. Generally, biodegradable compounds do not have these drawbacks, but they are comparatively more expensive. Both metal coagulants and biodegradable compounds have preferential and penalizing properties in terms of CAPS application. The problem can be solved by means of a multi-criteria analysis. For this purpose, a series of tests was performed in order to compare the efficacy of several organic and mixed-organic polymers with that of polyaluminium chloride (PACl) under specific conditions. The multi-criteria analysis was carried out coupling the simple additive weighting method with the paired comparison technique as a tool to evaluate the criteria priorities. Five criteria with the following priorities were used: chemical oxygen demand (COD) removal > turbidity, SV60 > coagulant dose, and coagulant cost. The PACl was the best alternative in 70% of the cases. The CAPS process using PACl made it possible to obtain an average COD removal of 68% compared with 38% obtained, on average, with natural sedimentation and 61% obtained, on average, with the best PACl alternatives (cationic polyacrylamide, natural cationic polymer, dicyandiamide resin).
El-Fadel, M; Matar, F; Hashisho, J
2013-05-01
The treatability of high-strength landfill leachate is challenging and relatively limited. This study examines the feasibility of treating high-strength landfill leachate (chemical oxygen demand [COD]: 7,760-11,770 mg/L, biochemical oxygen demand [BOD5]: 2,760-3,569 mg/L, total nitrogen [TN] = 980-1,160 mg/L) using a sequencing batch reactor (SBR) preceded by a coagulation-flocculation process with phosphorus nutritional balance under various mixing and aeration patterns. Simulations were also conducted to define kinetic parameters and COD fractionation. Removal efficiencies reached 89% for BOD5, 60% for COD, and 72% for TN, similar to and better than reported studies, albeit with a relatively lower hydraulic retention time (HRT) and solid retention time (SRT). The coupled experimental and simulation results contribute in filling a gap toward managing high-strength landfill leachate and providing guidelines for corresponding SBR applications. The treatability of high-strength landfill leachate, which is challenging and relatively limited, was demonstrated using a combined coagulation-flocculation with SBR technology and nutrient balance adjustment. The most suitable coagulant, kinetic design parameters, and COD fractionation were defined using coupled experimental and simulation results contributing in filling a gap toward managing high-strength leachate by providing guidelines for corresponding SBR applications and anticipating potential constraints related to the non-biodegradable COD fraction. In this context, while the combined coagulation-flocculation and SBR process improved removal efficiencies, posttreatment may be required for high-strength leachate, depending on discharge standards and ultimate usage of the treated leachate.
Pramanik, Biplob Kumar; Kajol, Annaduzzaman; Suja, Fatihah; Md Zain, Shahrom
2017-03-01
Biological aerated filter (BAF), sand filtration (SF), alum and Moringa oleifera coagulation were investigated as a pre-treatment for reducing the organic and biofouling potential component of an ultrafiltration (UF) membrane in the treatment of lake water. The carbohydrate content was mainly responsible for reversible fouling of the UF membrane compared to protein or dissolved organic carbon (DOC) content. All pre-treatment could effectively reduce these contents and led to improve the UF filterability. Both BAF and SF markedly led to improvement in flux than coagulation processes, and alum gave greater flux than M. oleifera. This was attributed to the effective removal and/or breakdown of high molecular weight (MW) organics by biofilters. BAF led to greater improvement in flux than SF, due to greater breakdown of high MW organics, and this was also confirmed by the attenuated total reflection-Fourier transform infrared spectroscopy analysis. Coagulation processes were ineffective in removing biofouling potential components, whereas both biofilters were very effective as shown by the reduction of low MW organics, biodegradable dissolved organic carbon and assimilable organic carbon contents. This study demonstrated the potential of biological pre-treatments for reducing organic and biofouling potential component and thus improving flux for the UF of lake water treatment.
Liu, Jie; Xu, Shenghua; Sun, Zhiwei
2007-11-06
Our previous studies have shown that the determination of coagulation rate constants by turbidity measurement becomes impossible for a certain operating wavelength (that is, its blind point) because at this wavelength the change in the turbidity of a dispersion completely loses its response to the coagulation process. Therefore, performing the turbidity measurement in the wavelength range near the blind point should be avoided. In this article, we demonstrate that the turbidity measurement of the rate constant for coagulation of a binary dispersion containing particles of two different sizes (heterocoagulation) presents special difficulties because the blind point shifts with not only particle size but also with the component fraction. Some important aspects of the turbidity measurement for the heterocoagulation rate constant are discussed and experimentally tested. It is emphasized that the T-matrix method can be used to correctly evaluate extinction cross sections of doublets formed during the heterocoagulation process, which is the key data determining the rate constant from the turbidity measurement, and choosing the appropriate operating wavelength and component fraction are important to achieving a more accurate rate constant. Finally, a simple scheme in experimentally determining the sensitivity of the turbidity changes with coagulation over a wavelength range is proposed.
Watson, Malcolm Alexander; Tubić, Aleksandra; Agbaba, Jasmina; Nikić, Jasmina; Maletić, Snežana; Molnar Jazić, Jelena; Dalmacija, Božo
2016-07-15
Interactions between arsenic and natural organic matter (NOM) are key limiting factors during the optimisation of drinking water treatment when significant amounts of both must be removed. This work uses Response Surface Methodology (RSM) to investigate how they interact during their simultaneous removal by iron chloride coagulation, using humic acid (HA) as a model NOM substance. Using a three factor Box-Behnken experimental design, As and HA removals were modelled, as well as a combined removal response. ANOVA results showed the significance of the coagulant dose for all three responses. At high initial arsenic concentrations (200μg/l), As removal was significantly hindered by the presence of HA. In contrast, the HA removal response was found to be largely independent of the initial As concentration, with the optimum coagulant dose increasing at increasing HA concentrations. The combined response was similar to the HA removal response, and the interactions evident are most interesting in terms of optimising treatment processes during the preparation of drinking water, highlighting the importance of utilizing RSM for such investigations. The combined response model was successfully validated with two different groundwaters used for drinking water supply in the Republic of Serbia, showing excellent agreement under similar experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.
Modeling of Electrochemical Process for the Treatment of Wastewater Containing Organic Pollutants
NASA Astrophysics Data System (ADS)
Rodrigo, Manuel A.; Cañizares, Pablo; Lobato, Justo; Sáez, Cristina
Electrocoagulation and electrooxidation are promising electrochemical technologies that can be used to remove organic pollutants contained in wastewaters. To make these technologies competitive with the conventional technologies that are in use today, a better understanding of the processes involved must be achieved. In this context, the development of mathematical models that are consistent with the processes occurring in a physical system is a relevant advance, because such models can help to understand what is happening in the treatment process. In turn, a more detailed knowledge of the physical system can be obtained, and tools for a proper design of the processes, or for the analysis of operating problems, are attained. The modeling of these technologies can be carried out using single-variable or multivariable models. Likewise, the position dependence of the model species can be described with different approaches. In this work, a review of the basics of the modeling of these processes and a description of several representative models for electrochemical oxidation and coagulation are carried out. Regarding electrooxidation, two models are described: one which summarizes the pollution of a wastewater in only one model species and that considers a macroscopic approach to formulate the mass balances and other that considers more detailed profile of concentration to describe the time course of pollutants and intermediates through a mixed maximum gradient/macroscopic approach. On the topic of electrochemical coagulation, two different approaches are also described in this work: one that considers the hydrodynamic conditions as the main factor responsible for the electrochemical coagulation processes and the other that considers the chemical interaction of the reagents and the pollutants as the more significant processes in the description of the electrochemical coagulation of organic compounds. In addition, in this work it is also described a multivariable model for the electrodissolution of anodes (first stage in electrocoagulation processes). This later model use a mixed macroscopic/maximum gradient approach to describe the chemical and electrochemical processes and it also assumes that the rates of all processes are very high, and that they can be successfully modeled using pseudoequilibrium approaches.
An alternative process to treat boiler feed water for reuse.
Guirgis, Adel; Ghosh, Jyoti P; Achari, Gopal; Langford, Cooper H; Banerjee, Daliya
2012-09-01
A bench-scale process to treat boiler feed water for reuse in steam generation was developed. Industrial water samples from a steam-assisted gravity drainage plant in northern Alberta, Canada, were obtained and samples characterized. The technology, which consists of coagulation-settling to remove oil/grease and particulates followed by an advanced oxidative treatment, led to clean water samples with negligible organic carbon. Coagulation followed by settling removed most particulates and some insoluble organics. The advanced oxidative treatment removed any remaining color in the samples, decreased the organic content to near-zero, and provided water ready for reuse.
Process to produce lithium-polymer batteries
MacFadden, Kenneth Orville
1998-01-01
A polymer bonded sheet product suitable for use as an electrode in a non-aqueous battery system. A porous electrode sheet is impregnated with a solid polymer electrolyte, so as to diffuse into the pores of the electrode. The composite is allowed to cool, and the electrolyte is entrapped in the porous electrode. The sheet products composed have the solid polymer electrolyte composition diffused into the active electrode material by melt-application of the solid polymer electrolyte composition into the porous electrode material sheet. The solid polymer electrolyte is maintained at a temperature that allows for rapid diffusion into the pores of the electrode. The composite electrolyte-electrode sheets are formed on current collectors and can be coated with solid polymer electrolyte prior to battery assembly. The interface between the solid polymer electrolyte composite electrodes and the solid polymer electrolyte coating has low resistance.
Anode film formation and control
Koski, Oscar; Marschman, Steven C.
1990-01-01
A protective film is created about the anode within a cryolite-based electrolyte during electrolytic production of aluminum from alumina. The film function to minimize corrosion of the anode by the cryolitic electrolyte and thereby extend the life of the anode. Various operating parameters of the electrolytic process are controlled to maintain the protective film about the anode in a protective state throughout the electrolytic reduction of alumina. Such parameters include electrolyte temperature, electrolyte ratio, current density, and Al.sub.2 O.sub.3 concentration. An apparatus is also disclosed to enable identification of the onset of anode corrosion due to disruption of the film to provide real time information regarding the state of the film.
Anode film formation and control
Koski, O.; Marschman, S.C.
1990-05-01
A protective film is created about the anode within a cryolite-based electrolyte during electrolytic production of aluminum from alumina. The film functions to minimize corrosion of the anode by the cryolitic electrolyte and thereby extend the life of the anode. Various operating parameters of the electrolytic process are controlled to maintain the protective film about the anode in a protective state throughout the electrolytic reduction of alumina. Such parameters include electrolyte temperature, electrolyte ratio, current density, and Al[sub 2]O[sub 3] concentration. An apparatus is also disclosed to enable identification of the onset of anode corrosion due to disruption of the film to provide real time information regarding the state of the film. 3 figs.
Anand, S; Mayya, Y S
2015-03-01
The long lived naturally occurring radon progeny species in the atmosphere, namely (210)Pb, (210)Bi and (210)Po, have been used as important tracers for understanding the atmospheric mixing processes and estimating aerosol residence times. Several observations in the past have shown that the activity size distribution of these species peaks at larger particle sizes as compared to the short lived radon progeny species - an effect that has been attributed to the process of coagulation of the background aerosols to which they are attached. To address this issue, a mathematical equation is derived for the activity-size distribution of tracer species by formulating a generalized distribution function for the number of tracer atoms present in coagulating background particles in the presence of radioactive decay and removal. A set of these equations is numerically solved for the progeny chain using Fuchs coagulation kernel combined with a realistic steady-state aerosol size spectrum that includes nucleation, accumulation and coarse mode components. The important findings are: (i) larger shifts in the modal sizes of (210)Pb and (210)Po at higher aerosol concentrations such as that found in certain Asian urban regions (ii) enrichment of tracer specific activity on particles as compared to that predicted by pure attachment laws (iii) sharp decline of daughter-to-parent activity ratios for decreasing particle sizes. The implication of the results to size-fractionated residence time estimation techniques is highlighted. A coagulation corrected graphical approach is presented for estimating the residence times from the size-segregated activity ratios of (210)Bi and (210)Po with respect to (210)Pb. The discrepancy between the residence times predicted by conventional formula and the coagulation corrected approach for specified activity ratios increases at higher atmospheric aerosol number concentrations (>10(10) #/m(3)) for smaller sizes (<1 μm). The results are further discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.
Titania nanotube powders obtained by rapid breakdown anodization in perchloric acid electrolytes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, Saima, E-mail: saima.ali@aalto.fi; Hannula, Simo-Pekka
Titania nanotube (TNT) powders are prepared by rapid break down anodization (RBA) in a 0.1 M perchloric acid (HClO{sub 4}) solution (Process 1), and ethylene glycol (EG) mixture with HClO{sub 4} and water (Process 2). A study of the as-prepared and calcined TNT powders obtained by both processes is implemented to evaluate and compare the morphology, crystal structure, specific surface area, and the composition of the nanotubes. Longer TNTs are formed in Process 1, while comparatively larger pore diameter and wall thickness are obtained for the nanotubes prepared by Process 2. The TNTs obtained by Process 1 are converted tomore » nanorods at 350 °C, while nanotubes obtained by Process 2 preserve tubular morphology till 350 °C. In addition, the TNTs prepared by an aqueous electrolyte have a crystalline structure, whereas the TNTs obtained by Process 2 are amorphous. Samples calcined till 450 °C have XRD peaks from the anatase phase, while the rutile phase appears at 550 °C for the TNTs prepared by both processes. The Raman spectra also show clear anatase peaks for all samples except the as-prepared sample obtained by Process 2, thus supporting the XRD findings. FTIR spectra reveal the presence of O-H groups in the structure for the TNTs obtained by both processes. However, the presence is less prominent for annealed samples. Additionally, TNTs obtained by Process 2 have a carbonaceous impurity present in the structure attributed to the electrolyte used in that process. While a negligible weight loss is typical for TNTs prepared from aqueous electrolytes, a weight loss of 38.6% in the temperature range of 25–600 °C is found for TNTs prepared in EG electrolyte (Process 2). A large specific surface area of 179.2 m{sup 2} g{sup −1} is obtained for TNTs prepared by Process 1, whereas Process 2 produces nanotubes with a lower specific surface area. The difference appears to correspond to the dimensions of the nanotubes obtained by the two processes. - Graphical abstract: Titania nanotube powders prepared by Process 1 and Process 2 have different crystal structure and specific surface area. - Highlights: • Titania nanotube (TNT) powder is prepared in low water organic electrolyte. • Characterization of TNT powders prepared from aqueous and organic electrolyte. • TNTs prepared by Process 1 are crystalline with higher specific surface area. • TNTs obtained by Process 2 have carbonaceous impurities in the structure.« less
Electrolyte Loss Tendencies of Primary Silver-Zinc Cells
NASA Technical Reports Server (NTRS)
Thaller, Lawrence H.; Juvinall, Gordon L.
1997-01-01
Since silver zinc cells are not hermetically sealed, care must be taken to prevent the loss of electrolyte which can result in shorting paths within the battery box. Prelaunch battery processing is important in being able to minimize any problems with expelled electrolyte.
Joh, Dong Woo; Park, Jeong Hwa; Kim, Doyeub; Wachsman, Eric D; Lee, Kang Taek
2017-03-15
A functionally graded Bi 1.6 Er 0.4 O 3 (ESB)/Y 0.16 Zr 0.84 O 1.92 (YSZ) bilayer electrolyte is successfully developed via a cost-effective screen printing process using nanoscale ESB powders on the tape-cast NiO-YSZ anode support. Because of the highly enhanced oxygen incorporation process at the cathode/electrolyte interface, a novel bilayer solid oxide fuel cell (SOFC) yields extremely high power density of ∼2.1 W cm -2 at 700 °C, which is a 2.4 times increase compared to that of the YSZ single electrolyte SOFC.
Wang, Feng; Gao, Baoyu; Yue, Qinyan; Bu, Fan; Shen, Xue
2017-07-01
Effects of ozonation and powdered activated carbon on removal of dissolved organic matter (DOM) and disinfection by-product (DBP) in reservoir water were intensively investigated in this study. Both the formation of carbonaceous DBP (C-DBP) and nitrogenous DBP (N-DBP) as well as their speciation were analyzed. Results exhibited that the addition of powdered activated carbon (PAC) greatly improved the removal of aromatic protein. Trihalomethanes (THMs) and haloacetonitriles (HANs) were the dominant species in C-DBP and N-DBP. The integrated coagulation and PAC processes could remove more than 70% of THMs and 93% of HANs precursors, while only 10.5 and 45% of capture were achieved by the single coagulation. The added ozone lowered the yields of HANs but synchronously increased the more toxic bromine-containing THMs from 78.5 to 128.1 μg/L. Kinetics parameters for THM formation indicated that the precursor creating the THMs fast could be easily removed by both the coagulation and PAC adsorption.
Characterization of Natural Organic Matter by FeCl3 Coagulation
NASA Astrophysics Data System (ADS)
Cahyonugroho, O. H.; Hidayah, E. N.
2018-01-01
Natural organic matter (NOM) is heterogenous mixture of organic compounds that enter the water from various decomposition and metabolic reactions, including animal, plant, domestic and industrial wastes. NOM refers to group of carbon-based compounds that are found in surface water and ground water. The aim of the study is to assess organic matter characteristics in Jagir River as drinking water source and to characterize the organic components that could be removed during coagulation. Coagulation is the common water treatment process can be used to remove NOM with FeCl3 coagulant in various dosage. NOM surrogates, including total organic carbon (TOC), ultraviolet absorbance at 254 nm (UV254) and specific UV absorbance (SUVA) were chosen to assess the organic removal. Results of jar test experiments showed that NOM can be removed about 40% of NOM surrogates with 200 mg/L FeCl3. About 60% removal of total organic fraction, which is mainly humic substances, as detected by size exclusion chromatography (SEC).
NASA Astrophysics Data System (ADS)
Huo, Zhipeng; Wang, Lu; Tao, Li; Ding, Yong; Yi, Jinxin; Alsaedi, Ahmed; Hayat, Tasawar; Dai, Songyuan
2017-08-01
A supramolecular gel electrolyte (Tgel > 100 °C) is formed from N,N‧-1,8-octanediylbis-dodecanamide and iodoacetamide as two-component co-gelator, and introduced into the quasi-solid-state dye-sensitized solar cells (QS-DSSCs). The different morphologies of microscopic network between two-component and single-component gel electrolytes have influence on the diffusion of redox couple in gel electrolytes and further affect the electron kinetic processes in QS-DSSCs. Compared with the single-component gel electrolyte, the two-component gel electrolyte has less compact gel network and weaker steric hindrance effect, which provides more effective charge transport channel for the diffusion of I3/I- redox couple. Meanwhile, the sbnd NH2 groups of iodoacetamide molecules interact with Li+ and I3-, which also accelerate the transport of I3-/I- and decrease in the I3- concentration in the TiO2/electrolyte interface. As a result, nearly a 12% improvement in short-circuit photocurrent density (Jsc) and much higher open circuit potential (Voc) are found in the two-component gel electrolyte based QS-DSSC. Consequently, the QS-DSSC based on the supramolecular gel electrolyte obtains a 17% enhancement in the photoelectric conversion efficiency (7.32%) in comparison with the QS-DSSC based on the single-component gel electrolyte (6.24%). Furthermore, the degradations of these QS-DSSCs are negligible after one sun light soaking with UV cutoff filter at 50 °C for 1000 h.
Dose of Biocoagulant-Mixing Rate Combinations for Optimum Reduction of COD in Wastewater
NASA Astrophysics Data System (ADS)
Patricia, Maria Faustina; Purwono; Budihardjo, Mochamad Arief
2018-02-01
Chemical oxygen demand (COD) in domestic wastewater can be treated using flocculation-coagulation process with addition of Oyster mushroom (Pleurotus ostreatus) in powder form as biocoagulant. The fungal cell wall of Oyster mushroom comprises of chitin that is high polyelectrolyte and can be function as an absorbent of heavy metals in wastewater. The effectiveness of flocculation-coagulation process in treating wastewater depends on dose of coagulant and mixing rate. Therefore, this study aims to determine the best combination of three variation of dose of biocoagulant which are 600 mg/l, 1000 mg/l, and 2000 mg/l and mixing rate which are 100 rpm, 125 rpm, and 150 rpm that give the most reduction of COD in the wastewater. The result indicates that the combination of 1000 mg/l of biocoagulant and 100 rpm of mixing rate were found to be the most optimum combination to treat COD in the wastewater with COD reduction of 47.7%.
Zou, Xiao-Ling
2017-10-01
A combined process of coagulation-catalytic ozonation-anaerobic sequencing batch reactor (ASBR)-SBR was developed at lab scale for treating a real sodium dithionite wastewater with an initial chemical oxygen demand (COD) of 21,760-22,450 mg/L. Catalytic ozonation with the prepared cerium oxide (CeO 2 )/granular activated carbon catalyst significantly enhances wastewater biodegradability and reduces wastewater microtoxicity. The results show that, under the optimum conditions, the removal efficiencies of COD and suspended solids are averagely 99.3% and 95.6%, respectively, and the quality of final effluent can meet the national discharge standard of China. The coagulation and ASBR processes remove a considerable proportion of organic matter, while the SBR plays an important role in post-polish of final effluent. The ecotoxicity of the wastewater is greatly reduced after undergoing the hybrid treatment. This work demonstrates that the hybrid system has the potential to be applied for the advanced treatment of high-strength industrial wastewater.
Kapse, Gaurav; Patoliya, Pruthvi; Samadder, S R
2017-03-01
The huge quantity of effluent generated in coal washing processes contains large amount of suspended and dissolved solids, clay minerals, coal fines and other impurities associated with raw coal. The present system of recirculation of the effluent is found to be ineffective in removing colloidal fines, which is the major part of the impurities present in washery effluent. Hence, there is a need for the assessment of a better technique for an efficient removal of these impurities. This study deals with detailed characterisation of coal washery effluent and fine particles present in it. For efficient removal of impurities, the suitability of biocoag-flocculation process using Moringa oleifera seed biomass as a natural coagulant was examined. Various doses of M. oleifera ranging from 0.2 to 3 mL/L were used in order to determine the optimal conditions. The impact of the variations in pH of the effluent (2-10), contact time (5-30 min), settlement time (5-50 min), temperature (10-50 °C) and the effluent dilution (1:0-1:5) was also assessed to optimise the treatment process. Post treatment analysis was carried out for determination of the different parameters such as pH, conductivity, turbidity, solids and settling velocity. Excellent reduction in turbidity (97.42%) and suspended solids (97.78%) was observed at an optimum dose of M. oleifera seed coagulant of 0.8 mL/L with an optimum contact time of 15 and at 20 min of settling time. In comparison with very few past studies of M. oleifera in the treatment of coal washery effluent with high dose and inadequate removal, this study stands to be a major highlight with low dose and high removal of the impurities. M. oleifera coagulant is considered to be an environment-friendly material, therefore, its application is recommended for simple and efficient treatment of coal washery effluent.
Makene, Vedastus W; Tijani, Jimoh O; Petrik, Leslie F; Pool, Edmund J
2016-08-01
Effective treatment of textile effluent prior to discharge is necessary in order to avert the associated adverse health impacts on human and aquatic life. In the present investigation, coagulation/flocculation processes were evaluated for the effectiveness of the individual treatment. Effectiveness of the treatment was evaluated based on the physicochemical characteristics. The quality of the pre-treated and post-flocculation treated effluent was further evaluated by determination of cytotoxicity and inflammatory activity using RAW264.7 cell cultures. Cytotoxicity was determined using WST-1 assay. Nitric oxide (NO) and interleukin 6 (IL-6) were used as biomarkers of inflammation. NO was determined in cell culture supernatant using the Griess reaction assay. The IL-6 secretion was determined using double antibody sandwich enzyme linked immunoassay (DAS ELISA). Cytotoxicity results show that raw effluent reduced the cell viability significantly (P < 0.001) compared to the negative control. All effluent samples treated by coagulation/flocculation processes at 1 in 100 dilutions had no cytotoxic effects on RAW264.7 cells. The results on inflammatory activities show that the raw effluent and effluent treated with 1.6 g/L of Fe-Mn oxide induced significantly (P < 0.001) higher NO production than the negative control. The inflammatory results further show that the raw effluent induced significantly (P < 0.001) higher production of IL-6 than the negative control. Among the coagulants/flocculants evaluated Al2(SO4)3.14H2O at a dosage of 1.6 g/L was the most effective to remove both toxic and inflammatory pollutants. In conclusion, the inflammatory responses in RAW264.7 cells can be used as sensitive biomarkers for monitoring the effectiveness of coagulation/flocculation processes used for textile effluent treatment.
Modeling dust growth in protoplanetary disks: The breakthrough case
NASA Astrophysics Data System (ADS)
Drążkowska, J.; Windmark, F.; Dullemond, C. P.
2014-07-01
Context. Dust coagulation in protoplanetary disks is one of the initial steps toward planet formation. Simple toy models are often not sufficient to cover the complexity of the coagulation process, and a number of numerical approaches are therefore used, among which integration of the Smoluchowski equation and various versions of the Monte Carlo algorithm are the most popular. Aims: Recent progress in understanding the processes involved in dust coagulation have caused a need for benchmarking and comparison of various physical aspects of the coagulation process. In this paper, we directly compare the Smoluchowski and Monte Carlo approaches to show their advantages and disadvantages. Methods: We focus on the mechanism of planetesimal formation via sweep-up growth, which is a new and important aspect of the current planet formation theory. We use realistic test cases that implement a distribution in dust collision velocities. This allows a single collision between two grains to have a wide range of possible outcomes but also requires a very high numerical accuracy. Results: For most coagulation problems, we find a general agreement between the two approaches. However, for the sweep-up growth driven by the "lucky" breakthrough mechanism, the methods exhibit very different resolution dependencies. With too few mass bins, the Smoluchowski algorithm tends to overestimate the growth rate and the probability of breakthrough. The Monte Carlo method is less dependent on the number of particles in the growth timescale aspect but tends to underestimate the breakthrough chance due to its limited dynamic mass range. Conclusions: We find that the Smoluchowski approach, which is generally better for the breakthrough studies, is sensitive to low mass resolutions in the high-mass, low-number tail that is important in this scenario. To study the low number density features, a new modulation function has to be introduced to the interaction probabilities. As the minimum resolution needed for breakthrough studies depends strongly on setup, verification has to be performed on a case by case basis.
Stabilizing lithium metal using ionic liquids for long-lived batteries
Basile, A.; Bhatt, A. I.; O'Mullane, A. P.
2016-01-01
Suppressing dendrite formation at lithium metal anodes during cycling is critical for the implementation of future lithium metal-based battery technology. Here we report that it can be achieved via the facile process of immersing the electrodes in ionic liquid electrolytes for a period of time before battery assembly. This creates a durable and lithium ion-permeable solid–electrolyte interphase that allows safe charge–discharge cycling of commercially applicable Li|electrolyte|LiFePO4 batteries for 1,000 cycles with Coulombic efficiencies >99.5%. The tailored solid–electrolyte interphase is prepared using a variety of electrolytes based on the N-propyl-N-methylpyrrolidinium bis(fluorosulfonyl)imide room temperature ionic liquid containing lithium salts. The formation is both time- and lithium salt-dependant, showing dynamic morphology changes, which when optimized prevent dendrite formation and consumption of electrolyte during cycling. This work illustrates that a simple, effective and industrially applicable lithium metal pretreatment process results in a commercially viable cycle life for a lithium metal battery. PMID:27292652
Fast formation cycling for lithium ion batteries
An, Seong Jin; Li, Jianlin; Du, Zhijia; ...
2017-01-09
The formation process for lithium ion batteries typically takes several days or more, and it is necessary for providing a stable solid electrolyte interphase on the anode (at low potentials vs. Li/Li +) for preventing irreversible consumption of electrolyte and lithium ions. An analogous layer known as the cathode electrolyte interphase layer forms at the cathode at high potentials vs. Li/Li +. However, several days, or even up to a week, of these processes result in either lower LIB production rates or a prohibitively large size of charging-discharging equipment and space (i.e. excessive capital cost). In this study, a fastmore » and effective electrolyte interphase formation protocol is proposed and compared with an Oak Ridge National Laboratory baseline protocol. Graphite, NMC 532, and 1.2 M LiPF 6 in ethylene carbonate: diethyl carbonate were used as anodes, cathodes, and electrolytes, respectively. Finally, results from electrochemical impedance spectroscopy show the new protocol reduced surface film (electrolyte interphase) resistances, and 1300 aging cycles show an improvement in capacity retention.« less
Olson, J.M.; Carleton, K.L.
1982-06-10
A process of producing silicon includes forming an alloy of copper and silicon and positioning the alloy in a dried, molten salt electrolyte to form a solid anode structure therein. An electrically conductive cathode is placed in the electrolyte for plating silicon thereon. The electrolyte is then purified to remove dissolved oxides. Finally, an electrical potential is applied between the anode and cathode in an amount sufficient to form substantially pure silicon on the cathode in the form of substantially dense, coherent deposits.
Olson, Jerry M.; Carleton, Karen L.
1984-01-01
A process for producing silicon includes forming an alloy of copper and silicon and positioning the alloy in a dried, molten salt electrolyte to form a solid anode structure therein. An electrically conductive cathode is placed in the electrolyte for plating silicon thereon. The electrolyte is then purified to remove dissolved oxides. Finally, an electrical potential is applied between the anode and cathode in an amount sufficient to form substantially pure silicon on the cathode in the form of substantially dense, coherent deposits.
Process to produce lithium-polymer batteries
MacFadden, K.O.
1998-06-30
A polymer bonded sheet product is described suitable for use as an electrode in a non-aqueous battery system. A porous electrode sheet is impregnated with a solid polymer electrolyte, so as to diffuse into the pores of the electrode. The composite is allowed to cool, and the electrolyte is entrapped in the porous electrode. The sheet products composed have the solid polymer electrolyte composition diffused into the active electrode material by melt-application of the solid polymer electrolyte composition into the porous electrode material sheet. The solid polymer electrolyte is maintained at a temperature that allows for rapid diffusion into the pores of the electrode. The composite electrolyte-electrode sheets are formed on current collectors and can be coated with solid polymer electrolyte prior to battery assembly. The interface between the solid polymer electrolyte composite electrodes and the solid polymer electrolyte coating has low resistance. 1 fig.
Advanced electrolyte/additive for lithium-ion batteries with silicon anode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Shuo; He, Meinan; Su, Chi-Cheung
State-of-the-art lithium-ion batteries (LIBs) are based on a lithium transition metal oxide cathode, a graphite anode and a nonaqueous carbonate electrolyte. To further increase the energy and power density of LIBs, silicon anodes have been intensively explored due to their high theoretical capacity, low operation potential, and low cost. However, the main challenges for Si anode are the large volume change during lithiation/delithiation process and the instability of the solid-electrolyte-interphase associated with this process. Recently, significant progress has been achieved via advanced material fabrication technologies and rational electrolyte design in terms of improving the Coulombic efficiency and capacity retention. Inmore » this paper, new developments in advanced electrolyte and additive for LIBs with Si anode were systematically reviewed, and perspectives over future research were suggested.« less
ERIC Educational Resources Information Center
Zoltek, J., Jr.; Melear, E. L.
1978-01-01
Presents the 1978 literature review of wastewater treatment. This review covers: (1) process application; (2) coagulation and solids separation; (3) adsorption; (4) ion exchange; (5) membrane processes; and (6) oxidation processes. A list of 123 references is also presented. (HM)
The Effects of Hypothermia on Fibrinogen Metabolism and Coagulation Function in Swine
2007-01-01
blanket with circulating water at 48C. Fibrinogen synthesis and breakdown were quantified using a 6-hour stable isotope infusion with subsequent gas...tion and sufficient fibrinogen in the circulation . The effects of hypothermia on the coagulation process have been estimated 0026-0495/$ – see front...and released to circulation in 1 hour. Fibrinogen breakdown rate is the total loss of fibrinogen (expressed as milligram per kilogram of body weight
NASA Astrophysics Data System (ADS)
Hozé, Nathanaël; Holcman, David
2012-01-01
We develop a coagulation-fragmentation model to study a system composed of a small number of stochastic objects moving in a confined domain, that can aggregate upon binding to form local clusters of arbitrary sizes. A cluster can also dissociate into two subclusters with a uniform probability. To study the statistics of clusters, we combine a Markov chain analysis with a partition number approach. Interestingly, we obtain explicit formulas for the size and the number of clusters in terms of hypergeometric functions. Finally, we apply our analysis to study the statistical physics of telomeres (ends of chromosomes) clustering in the yeast nucleus and show that the diffusion-coagulation-fragmentation process can predict the organization of telomeres.
Sun, Binbin; Zhang, Yinqing; Chen, Wei; Wang, Kunkun; Zhu, Lingyan
2018-06-22
The impacts of a model globular protein (bovine serum albumin, BSA) on aggregation kinetics of graphene oxide (GO) in aquatic environment were investigated through time-resolved dynamic light scattering at pH 5.5. Aggregation kinetics of GO without BSA as a function of electrolyte concentrations (NaCl, MgCl 2 , and CaCl 2 ) followed the traditional Derjaguin-Landau-Verwey-Overbeek (DLVO) theory, and the critical coagulation concentration (CCC) was 190, 5.41, and 1.61 mM, respectively. As BSA was present, it affected the GO stability in a concentration dependent manner. At fixed electrolyte concentrations below the CCC values, for example 120 mM NaCl, the attachment efficiency of GO increased from 0.08 to 1, then decreased gradually and finally reached up to zero as BSA concentration increased from 0 to 66.5 mg C/L. The low-concentration BSA depressed GO stability mainly due to electrostatic binding between the positively charged lysine groups of BSA and negatively charged groups of GO, as well as double layer compression effect. With the increase of BSA concentration, more and more BSA molecules were adsorbed on GO, leading to strong steric repulsion which finally predominated and stabilized the GO. These results provided significant information about the concentration dependent effects of natural organic matters on GO stability under environmentally relevant conditions.
Cronin, Katherine R; Mangan, Thomas P; Carew, Josephine A
2012-01-01
Constitutive production of blood coagulation proteins by hepatocytes is necessary for hemostasis. Stressful conditions trigger adaptive cellular responses and delay processing of most proteins, potentially affecting plasma levels of proteins secreted exclusively by hepatocytes. We examined the effect of glucose deprivation on expression of coagulation proteins by the human hepatoma cell line, HepG2. Expression of coagulation factor VII, which is required for initiation of blood coagulation, was elevated by glucose deprivation, while expression of other coagulation proteins decreased. Realtime PCR and ELISA demonstrated that the relative percentage expression +/- SD of steady-state F7 mRNA and secreted factor VII antigen were significantly increased (from 100+/-15% to 188+/-27% and 100+/-8.8% to 176.3+/-17.3% respectively, p<0.001) at 24 hr of treatment. The integrated stress response was induced, as indicated by upregulation of transcription factor ATF4 and of additional stress-responsive genes. Small interfering RNAs directed against ATF4 potently reduced basal F7 expression, and prevented F7 upregulation by glucose deprivation. The response of the endogenous F7 gene was replicated in reporter gene assays, which further indicated that ATF4 effects were mediated via interaction with an amino acid response element in the F7 promoter. Our data indicated that glucose deprivation enhanced F7 expression in a mechanism reliant on prior ATF4 upregulation primarily due to increased transcription from the ATF4 gene. Of five coagulation protein genes examined, only F7 was upregulated, suggesting that its functions may be important in a systemic response to glucose deprivation stress.
Cronin, Katherine R.; Mangan, Thomas P.; Carew, Josephine A.
2012-01-01
Background Constitutive production of blood coagulation proteins by hepatocytes is necessary for hemostasis. Stressful conditions trigger adaptive cellular responses and delay processing of most proteins, potentially affecting plasma levels of proteins secreted exclusively by hepatocytes. We examined the effect of glucose deprivation on expression of coagulation proteins by the human hepatoma cell line, HepG2. Methodology/Principal Findings Expression of coagulation factor VII, which is required for initiation of blood coagulation, was elevated by glucose deprivation, while expression of other coagulation proteins decreased. Realtime PCR and ELISA demonstrated that the relative percentage expression +/− SD of steady-state F7 mRNA and secreted factor VII antigen were significantly increased (from 100+/−15% to 188+/−27% and 100+/−8.8% to 176.3+/−17.3% respectively, p<0.001) at 24 hr of treatment. The integrated stress response was induced, as indicated by upregulation of transcription factor ATF4 and of additional stress-responsive genes. Small interfering RNAs directed against ATF4 potently reduced basal F7 expression, and prevented F7 upregulation by glucose deprivation. The response of the endogenous F7 gene was replicated in reporter gene assays, which further indicated that ATF4 effects were mediated via interaction with an amino acid response element in the F7 promoter. Conclusions/Significance Our data indicated that glucose deprivation enhanced F7 expression in a mechanism reliant on prior ATF4 upregulation primarily due to increased transcription from the ATF4 gene. Of five coagulation protein genes examined, only F7 was upregulated, suggesting that its functions may be important in a systemic response to glucose deprivation stress. PMID:22848420
Shirasaki, N; Matsushita, T; Matsui, Y; Marubayashi, T; Murai, K
2016-09-01
We evaluated the removal of enteric adenovirus (AdV) type 40 and poliovirus (PV) type 1 by coagulation, using water samples from 13 water sources for drinking water treatment plants in Japan. The behaviors of two widely accepted enteric virus surrogates, bacteriophages MS2 and φX174, were compared with the behaviors of AdV and PV. Coagulation with polyaluminum chloride (PACl, basicity 1.5) removed AdV and PV from virus-spiked source waters: the infectious AdV and PV removal ratios evaluated by means of a plaque-forming-unit method were 0.1-1.4-log10 and 0.5-2.4-log10, respectively. A nonsulfated high-basicity PACl (basicity 2.1) removed infectious AdV and PV more efficiently than did other commercially available PACls (basicity 1.5-2.1), alum, and ferric chloride. The MS2 removal ratios tended to be larger than those of AdV and PV, partly because of differences in the hydrophobicities of the virus particles and the sensitivity of the virus to the virucidal activity of PACl; the differences in removal ratios were not due to differences in the surface charges of the virus particles. MS2, which was more hydrophobic than the other viruses, was inactivated during coagulation with PACl. Therefore, MS2 does not appear to be an appropriate surrogate for AdV and PV during coagulation. In contrast, because φX174, like AdV and PV, was not inactivated during coagulation, and because the hydrophobicity of φX174 was similar to or somewhat lower than the hydrophobicities of AdV and PV, the φX174 removal ratios tended to be similar to or somewhat smaller than those of the enteric viruses. Therefore, φX174 is a potential conservative surrogate for AdV and PV during coagulation. In summary, the surface hydrophobicity of virus particles and the sensitivity of the virus to the virucidal activity of the coagulant are probably important determinants of the efficiency of virus removal during coagulation. Copyright © 2016 Elsevier B.V. All rights reserved.
Chekli, L; Corjon, E; Tabatabai, S A A; Naidu, G; Tamburic, B; Park, S H; Shon, H K
2017-10-01
During algal bloom periods, operation of seawater reverse osmosis (SWRO) pretreatment processes (e.g. ultrafiltration (UF)) has been hindered due to the high concentration of algal cells and algal organic matter (AOM). The present study evaluated for the first time the performance of titanium salts (i.e. titanium tetrachloride (TiCl 4 ) and polytitanium tetrachloride (PTC)) for the removal of AOM in seawater and results were compared with the conventional FeCl 3 coagulant. Previous studies already demonstrated that titanium salts not only provide a cost-effective alternative to conventional coagulants by producing a valuable by-product but also minimise the environmental impact of sludge production. Results from this study showed that both TiCl 4 and PTC achieved better performance than FeCl 3 in terms of turbidity, UV 254 and dissolved organic carbon (DOC) removal at similar coagulant dose. Liquid chromatography - organic carbon detection (LC-OCD) was used to determine the removal of AOM compounds based on their molecular weight (MW). This investigation revealed that both humic substances and low MW organics were preferentially removed (i.e. up to 93% removal) while all three coagulants showed poorer performance for the removal of high MW biopolymers (i.e. less than 50% removal). The detailed characterization of flocs indicated that both titanium coagulants can grow faster, reach larger size and present a more compact structure, which is highly advantageous for the design of smaller and more compact mixing and sedimentation tanks. Both titanium coagulants also presented a higher ability to withstand shear force, which was related to the higher amount of DOC adsorbed with the aggregated flocs. Finally, TiCl 4 had a better recovery after breakage suggesting that charge neutralization may be the dominant mechanism for this coagulant, while the lower recovery of both PTC and FeCl 3 indicated that sweep flocculation is also a contributing mechanism for the coagulation of AOM. Copyright © 2017 Elsevier Ltd. All rights reserved.
Solid oxide electrochemical cell fabrication process
Dollard, Walter J.; Folser, George R.; Pal, Uday B.; Singhal, Subhash C.
1992-01-01
A method to form an electrochemical cell (12) is characterized by the steps of thermal spraying stabilized zirconia over a doped lanthanum manganite air electrode tube (14) to provide an electrolyte layer (15), coating conductive particles over the electrolyte, pressurizing the outside of the electrolyte layer, feeding halide vapors of yttrium and zirconium to the outside of the electrolyte layer and feeding a source of oxygen to the inside of the electrolyte layer, heating to cause oxygen reaction with the halide vapors to close electrolyte pores if there are any and to form a metal oxide coating on and between the particles and provide a fuel electrode (16).
NASA Astrophysics Data System (ADS)
Son, Hui-Jeong; Song, Rak-Hyun; Lim, Tak-Hyoung; Lee, Seung-Bok; Kim, Sung-Hyun; Shin, Dong-Ryul
The process of vacuum slurry coating for the fabrication of a dense and thin electrolyte film on a porous anode tube is investigated for application in solid oxide fuel cells. 8 mol% yttria stabilized zirconia is coated on an anode tube by vacuum slurry-coating process as a function of pre-sintering temperature of the anode tube, vacuum pressure, slurry concentration, number of coats, and immersion time. A dense electrolyte layer is formed on the anode tube after final sintering at 1400 °C. With decrease in the pre-sintering temperature of the anode tube, the grain size of the coated electrolyte layer increases and the number of surface pores in the coating layer decreases. This is attributed to a reduced difference in the respective shrinkage of the anode tube and the electrolyte layer. The thickness of the coated electrolyte layer increases with the content of solid powder in the slurry, the number of dip-coats, and the immersion time. Although vacuum pressure has no great influence on the electrolyte thickness, higher vacuum produces a denser coating layer, as confirmed by low gas permeability and a reduced number of defects in the coating layer. A single cell with the vacuum slurry coated electrolyte shows a good performance of 620 mW cm -2 (0.7 V) at 750 °C. These experimental results indicate that the vacuum slurry-coating process is an effective method to fabricate a dense thin film on a porous anode support.
Schaer, S; Herrli-Gygi, M; Kosmeas, N; Boschung, H; Steiner, A
2005-09-01
Abomasal emptying plays an important role in the incidence of digestive problems in calves. Our aim was to evaluate the acetaminophen absorption test (APAT) for characterization of the oroduodenal transit (ODT) of liquid meals in unweaned calves. Six healthy, unweaned Simmental x Red Holstein crossbred calves were involved in the project. The study was performed in three blocks at 3, 6 and 9 weeks of the calves' age. Within blocks, APAT was performed twice at an interval of at least 24 h. Once per each block, liquid transit was carried out with non-coagulating electrolyte solution (NES). The second test within a block was performed either while atropine sulphate was administered (block I), or by feeding a coagulating milk replacer (block II), or by administration of NES by ruminal tube (block III). Data were compared within and among blocks. Significant differences of several APAT traits were present for the different types of feeding, the different types of meals, the administration of atropine sulphate and the different ages of the calves. The emptying index T(max)/C(max) was suggested to be a valuable kinetic parameter for the characterization of ODT in these calves. We conclude that APAT represents a valid technique for characterization of ODT of liquid meals in healthy unweaned calves and may be a valuable tool for the evaluation of the reticular groove mechanism, the abomasal emptying and the absorption capacity of the duodenum.
Process for electrochemically gasifying coal
Botts, T.E.; Powell, J.R.
1985-10-25
A process is claimed for electrochemically gasifying coal by establishing a flowing stream of coal particulate slurry, electrolyte and electrode members through a transverse magnetic field that has sufficient strength to polarize the electrode members, thereby causing them to operate in combination with the electrolyte to electrochemically reduce the coal particulate in the slurry. Such electrochemical reduction of the coal produces hydrogen and carbon dioxide at opposite ends of the polarized electrode members. Gas collection means are operated in conjunction with the process to collect the evolved gases as they rise from the slurry and electrolyte solution. 7 figs.
Studies of metals electroprocessing in molten salts
NASA Technical Reports Server (NTRS)
Sadoway, D. R.
1982-01-01
Fluid flow patterns in molten salt electrolytes were observed in order to determine how mass transport affects the morphology of the metal deposit. Studies conducted on the same metal, both in aqueous electrolytes in which coherent solid electrodeposits are produced, as well as in transparent molten salt electrolytes are described. Process variables such as current density and composition of the electrolyte are adjusted to change the morphology of the electrodeposit and, thus, to permit the study of the nature of electrolyte flow in relation to the quality of the electrodeposit.
Electrolyte chemistry control in electrodialysis processing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayes, Thomas D.; Severin, Blaine F.
Methods for controlling electrolyte chemistry in electrodialysis units having an anode and a cathode each in an electrolyte of a selected concentration and a membrane stack disposed therebetween. The membrane stack includes pairs of cationic selective and anionic membranes to segregate increasingly dilute salts streams from concentrated salts stream. Electrolyte chemistry control is via use of at least one of following techniques: a single calcium exclusionary cationic selective membrane at a cathode cell boundary, an exclusionary membrane configured as a hydraulically isolated scavenger cell, a multivalent scavenger co-electrolyte and combinations thereof.
Formation and evolution of anodic TiO2 nanotube embryos
NASA Astrophysics Data System (ADS)
Jin, Rong; Liao, Maoying; Lin, Tong; Zhang, Shaoyu; Shen, Xiaoping; Song, Ye; Zhu, Xufei
2017-06-01
Anodic TiO2 nanotubes (ATNTs) have been widely investigated for decades due to their interesting nanostructures and various applications. However, the formation mechanism of ATNTs still remains unclear. To date, most of researches focus on the tubular structure but neglect the formation process of initial nanotube embryos. Herein, polyethylene glycol (PEG) is added into the traditional electrolyte to moderate the transformation process from compact layer to porous layer. Based on ‘oxygen bubble mould’ and ‘plastic flow model’ theory, the formation and evolution process of nanotube embryo is clarified firstly. Results validate the effect of ‘oxygen bubble mould’ on the formation of nanotube embryo, which has a great effect on regulating the morphology of ATNT arrays. Besides, nanotubes prepared in electrolytes with PEG show shorter tube length with larger diameter than that prepared in traditional electrolytes. The addition of PEG can also effectively avoid the breakdown phenomenon. Highlights Transformation from compact layer into porous layer is observed in PEG electrolyte. The effect of oxygen bubble mould is first demonstrated and observed. The formation process of TiO2 nanotube embryo is described systematically. TiO2 nanotubes prepared in PEG electrolyte show short length and large diameter.
Structural bioinformatics: methods, concepts and applications to blood coagulation proteins.
Villoutreix, Bruno O
2002-06-01
Structural and theoretical analyses of proteins are central to the understanding of complex molecular mechanisms and are fundamental to the drug discovery process. Computational techniques yield useful insights into an ever-wider range of biomolecular systems. Protein three-dimensional structures and molecular functions can be predicted in some circumstances, while experimental structures can be analyzed in depth via such computational approaches. Non-covalent binding of biomolecules can be understood by considering structural, thermodynamic and kinetic issues, and theoretical simulations of such events can be attempted. The central role of electrostatic interactions with regard to protein function, structure and stability has been investigated and some electrostatic properties can be modeled theoretically. Computer methods thus help to prioritize, design, analyze and rationalize biochemical experiments. Cardiovascular diseases and associated blood coagulation disorders are leading causes of death worldwide. Blood coagulation involves more than 30 proteins that interact specifically with various degrees of affinity. Many of these molecules can also bind transiently to phospholipid surfaces. Numerous point mutations in the genes of coagulation proteins and regulators have been identified. Understanding the coagulation cascade, its regulation and the impact of mutations is required for the development of new therapies and diagnostic tools. In this review, we describe concepts and methods pertaining to the field of structural bioinformatics. We provide examples of applications of these approaches to blood coagulation proteins and show that such studies can give insights about molecular mechanisms contributing to cardiovascular disease susceptibility.
NASA Astrophysics Data System (ADS)
Qiao, Xiaoping; Li, Helin; Zhao, Wenzhen; Li, Dejun
The absorption properties of zinc-nickel alloy electrolyte were studied by visible spectrophotometer. The results show that the relationship between the absorbance of the zinc-nickel alloy electrolyte and Ni2+ concentration in the electrolyte obeys Beer's law at 660 nm. In addition, other components except Ni2+ in the zinc-nickel alloy electrolyte such as zinc chloride, ammonium chloride, potassium chloride and boric acid have no obvious effect on the absorbance of zinc-nickel alloy electrolyte. Based on these properties, a new method is developed to determine Ni2+ concentration in zinc-nickel alloy electrolyte. Comparing with other methods, this method is simple, direct and accurate. Moreover, the whole testing process does not consume any reagent and dilution, and after testing, the electrolyte samples can be reused without any pollution to the environment.
Electrocoagulation of Palm Oil Mill Effluent
Agustin, Melissa B.; Sengpracha, Waya P.; Phutdhawong, Weerachai
2008-01-01
Electrocoagulation (EC) is an electrochemical technique which has been employed in the treatment of various kinds of wastewater. In this work the potential use of EC for the treatment of palm oil mill effluent (POME) was investigated. In a laboratory scale, POME from a factory site in Chumporn Province (Thailand) was subjected to EC using aluminum as electrodes and sodium chloride as supporting electrolyte. Results show that EC can reduce the turbidity, acidity, COD, and BOD of the POME as well as some of its heavy metal contents. Phenolic compounds are also removed from the effluent. Recovery techniques were employed in the coagulated fraction and the recovered compounds was analysed for antioxidant activity by DPPH method. The isolate was found to have a moderate antioxidant activity. From this investigation, it can be concluded that EC is an efficient method for the treatment of POME. PMID:19139537
Quality control in the development of coagulation factor concentrates.
Snape, T J
1987-01-01
Limitation of process change is a major factor contributing to assurance of quality in pharmaceutical manufacturing. This is particularly true in the manufacture of coagulation factor concentrates, for which presumptive testing for poorly defined product characteristics is an integral feature of finished product quality control. The development of new or modified preparations requires that this comfortable position be abandoned, and that the effect on finished product characteristics of changes to individual process steps (and components) be assessed. The degree of confidence in the safety and efficacy of the new product will be determined by, amongst other things, the complexity of the process alteration and the extent to which the results of finished product tests can be considered predictive. The introduction of a heat-treatment step for inactivation of potential viral contaminants in coagulation factor concentrates presents a significant challenge in both respects, quite independent of any consideration of assessment of the effectiveness of the viral inactivation step. These interactions are illustrated by some of the problems encountered with terminal dry heat-treatment (72 h. at 80 degrees C) of factor VIII and prothrombin complex concentrates manufactured by the Blood Products Laboratory.
Xie, Qiao-Guang; Taweepreda, Wirach; Musikavong, Charongpun; Suksaroj, Chaisri
2012-01-01
Treatment of waste glycerol, a by-product of the biodiesel production process, can reduce water pollution and bring significant economic benefits for biodiesel facilities. In the present study, hydrochloric acid (HCl) was used as acidification to convert soaps into salts and free fatty acids which were recovered after treatment. The pH value, dosages of polyaluminum chloride (PACl) and dosage of polyacrylamide (PAM) were considered to be the factors that can influence coagulation efficiency. The pH value of waste glycerol was adjusted to a pH range of 3-9. The PACl and PAM added were in the range of 1-6 g/L and 0.005-0.07 g/L. The results showed best coagulation efficiency occurs at pH 4 when dosage of PACl and PAM were 2 and 0.01 g/L. The removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD(5)), total suspended solids (TSS) and soaps were 80, 68, 97 and 100%, respectively. The compositions of organic matters in the treated waste glycerol were glycerol (288 g/L), methanol (3.8 g/L), and other impurities (0.3 g/L).
Removal of iron ore slimes from a highly turbid water by DAF.
Faustino, L M; Braga, A S; Sacchi, G D; Whitaker, W; Reali, M A P; Leal Filho, L S; Daniel, L A
2018-05-30
This paper addresses Dissolved Air Flotation (DAF) process variables, such as the flocculation parameters and the recycle water addition, as well as the pretreatment chemical variables (coagulation conditions), to determine the optimal values for the flotation of iron ore slimes found in a highly turbid water sample from the Gualaxo do Norte River, a tributary of the Doce River Basin in Minas Gerais, Brazil. This work was conducted using a flotatest batch laboratory-scale device to evaluate the effectiveness of DAF for cleaning the water polluted by the Samarco tailings dam leakage and determine the ability of DAF to reduce the water turbidity from 358 NTU to values below 100 NTU, aiming to comply with current legislation. The results showed that the four types of tested coagulants (PAC, ferric chloride, Tanfloc SG and Tanfloc SL) provided adequate conditions for coagulation, flocculation and flotation (in the range of 90-99.6% turbidity reduction). Although the process variables were optimized and low residual turbidity vales were achieved, results revealed that a portion of the flocs settled at the bottom of the flotatest columns, which indicated that the turbidity results represented removal caused by a combination of flotation and sedimentation processes simultaneously.
Low-level lasers: their role in the mechanisms of the stimulation of the reparative processes
NASA Astrophysics Data System (ADS)
Yeliseenko, Vladimir I.
1994-08-01
The transformation of light energy into thermal energy with extremely high temperatures, the evaporation of interstitial and intracellular fluids, and the cytoplasmic proteins coagulation are the most important factors in the mechanism of high-power lasers effect on biological tissues. A set of dystrophic disorders develops in tissues as a result, up to the coagulative necrosis, which lays in the basis of the laser thermal crust at incised edges. With CO2 laser the damage is evident from the first cell layers. Its size is in the linear correlation with exposure time. The Nd:YAG and argon lasers' light penetrates the superficial cell layers without damage practically and realizes in deeper well vascularized tissue layers, the submucous layer of the gastrointestinal hollow organs, in particular. It depends on the closeness of the irradiation spectrum of absorption of hemoglobin and result in blood coagulation in the vascular lumine with formation of the `coagulative laser thrombi.' That explains a wide use of laser irradiation in urgent endoscopy for arresting acute gastrointestinal hemorrhages. For these reasons Nd:YAG laser `contact scalpel' technique with sapphire tips is used for incisions on parenchymatous organs with simultaneous blood coagulation in vessels lumina with good hemostasis and holestasis (hepatobiliar surgery), and for pancreas and thyroid surgery, in gynecology and other surgical areas.
A method for the inline measurement of milk gel firmness using an optical sensor.
Arango, O; Castillo, M
2018-05-01
At present, selection of cutting time during cheesemaking is made based on subjective methods, which has effects on product homogeneity and has prevented complete automation of cheesemaking. In this work, a new method for inline monitoring of curd firmness is presented. The method consisted of developing a model that correlates the backscatter ratio of near infrared light during milk coagulation with the rheological storage modulus. The model was developed through a factorial design with 2 factors: protein concentration (3.4 and 5.1%) and coagulation temperature (30 and 40°C). Each treatment was replicated 3 times; the model was calibrated with the first replicate and validated using the remaining 2 replicates. The coagulation process was simultaneously monitored using an optical sensor and small-amplitude oscillatory rheology. The model was calibrated and successfully validated at the different protein concentrations and coagulation temperatures studied, predicting the evolution of storage modulus during milk coagulation with coefficient of determination values >0.998 and standard error of prediction values <3.4 Pa. The results demonstrated that the proposed method allows inline monitoring of curd firming in cheesemaking and cutting the curd at a proper firmness to each type of cheese. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Power density measurements to optimize AC plasma jet operation in blood coagulation.
Ahmed, Kamal M; Eldeighdye, Shaimaa M; Allam, Tarek M; Hassanin, Walaa F
2018-06-14
In this paper, the plasma power density and corresponding plasma dose of a low-cost air non-thermal plasma jet (ANPJ) device are estimated at different axial distances from the nozzle. This estimation is achieved by measuring the voltage and current at the substrate using diagnostic techniques that can be easily made in laboratory; thin wire and dielectric probe, respectively. This device uses a compressed air as input gas instead of the relatively-expensive, large-sized and heavy weighed tanks of Ar or He gases. The calculated plasma dose is found to be very low and allows the presented device to be used in biomedical applications (especially blood coagulation). While plasma active species and charged-particles are found to be the most effective on blood coagulation formation, both air flow and UV, individually, do not have any effect. Moreover, optimal conditions for accelerating blood coagulation are studied. Results showed that, the power density at the substrate is shown to be decreased with increasing the distance from the nozzle. In addition, both distances from nozzle and air flow rate play an important role in accelerating blood coagulation process. Finally, this device is efficient, small-sized, safe enough, of low cost and, hence, has its chances to be wide spread as a first aid and in ambulance.
Chemical modification of electrolytes for lithium batteries
NASA Astrophysics Data System (ADS)
Afanas'ev, Vladimir N.; Grechin, Aleksandr G.
2002-09-01
Modern approaches to modifying chemically electrolytes for lithium batteries are analysed with the aim of optimising the charge-transfer processes in liquid-phase and solid (polymeric) media. The main regularities of transport properties of lithium electrolyte solutions containing complex (encapsulated) ions in aprotic solvents and polymers are discussed. The prospects for the development of electrolytic solvosystems with the chain (ionotropic) mechanism of conduction with respect to lithium ions are outlined. The bibliography includes 126 references.
NASA Astrophysics Data System (ADS)
Gesing, Adam J.; Das, Subodh K.
2017-02-01
With United States Department of Energy Advanced Research Project Agency funding, experimental proof-of-concept was demonstrated for RE-12TM electrorefining process of extraction of desired amount of Mg from recycled scrap secondary Al molten alloys. The key enabling technology for this process was the selection of the suitable electrolyte composition and operating temperature. The selection was made using the FactSage thermodynamic modeling software and the light metal, molten salt, and oxide thermodynamic databases. Modeling allowed prediction of the chemical equilibria, impurity contents in both anode and cathode products, and in the electrolyte. FactSage also provided data on the physical properties of the electrolyte and the molten metal phases including electrical conductivity and density of the molten phases. Further modeling permitted selection of electrode and cell construction materials chemically compatible with the combination of molten metals and the electrolyte.
Mohamed-Zine, Messaoud-Boureghda; Hamouche, Aksas; Krim, Louhab
2013-12-19
Environmental impact assessment will soon become a compulsory phase in future potable water production projects, in algeria, especially, when alternative treatment processes such sedimentation ,coagulation sand filtration and Desinfection are considered. An impact assessment tool is therefore developed for the environmental evaluation of potable water production. in our study The evaluation method used is the life cycle assessment (LCA) for the determination and evaluation of potential impact of a drink water station ,near algiers (SEAL-Boudouaoua).LCA requires both the identification and quantification of materials and energy used in all stages of the product's life, when the inventory information is acquired, it will then be interpreted into the form of potential impact " eco-indicators 99" towards study areas covered by LCA, using the simapro6 soft ware for water treatment process is necessary to discover the weaknesses in the water treatment process in order for it to be further improved ensuring quality life. The main source shown that for the studied water treatment process, the highest environmental burdens are coagulant preparation (30% for all impacts), mineral resource and ozone layer depletion the repartition of the impacts among the different processes varies in comparison with the other impacts. Mineral resources are mainly consumed during alumine sulfate solution preparation; Ozone layer depletion originates mostly from tetrachloromethane emissions during alumine sulfate production. It should also be noted that, despite the small doses needed, ozone and active Carbone treatment generate significant impacts with a contribution of 10% for most of the impacts.Moreover impacts of energy are used in producing pumps (20-25 GHC) for plant operation and the unitary processes (coagulation, sand filtration decantation) and the most important impacts are localized in the same equipment (40-75 GHC) and we can conclude that:- Pre-treatment, pumping and EDR (EDR: 0.-6 0 kg CO2 eq. /produced m3) are the process-units with higher environmental impacts.- Energy consumption is the main source of impacts on climate change.- Chemicals consumption (e.g. coagulants, oxidants) are the principle cause of impacts on the ozone layer depletion.- Conventional plants: pre-treatment has high GHG emissions due to chemicals consumption.
Sédille-Mostafaie, Nazanin; Engler, Hanna; Lutz, Susanne; Korte, Wolfgang
2013-06-01
Laboratories today face increasing pressure to automate operations due to increasing workloads and the need to reduce expenditure. Few studies to date have focussed on the laboratory automation of preanalytical coagulation specimen processing. In the present study, we examined whether a clinical chemistry automation protocol meets the preanalytical requirements for the analyses of coagulation. During the implementation of laboratory automation, we began to operate a pre- and postanalytical automation system. The preanalytical unit processes blood specimens for chemistry, immunology and coagulation by automated specimen processing. As the production of platelet-poor plasma is highly dependent on optimal centrifugation, we examined specimen handling under different centrifugation conditions in order to produce optimal platelet deficient plasma specimens. To this end, manually processed models centrifuged at 1500 g for 5 and 20 min were compared to an automated centrifugation model at 3000 g for 7 min. For analytical assays that are performed frequently enough to be targets for full automation, Passing-Bablok regression analysis showed close agreement between different centrifugation methods, with a correlation coefficient between 0.98 and 0.99 and a bias between -5% and +6%. For seldom performed assays that do not mandate full automation, the Passing-Bablok regression analysis showed acceptable to poor agreement between different centrifugation methods. A full automation solution is suitable and can be recommended for frequent haemostasis testing.
Raghu, S; Ahmed Basha, C
2007-10-22
This paper examines the use of chemical or electrocoagulation treatment process followed by ion-exchange process of the textile dye effluent. The dye effluent was treated using polymeric coagulant (cationic dye-fixing agent) or electrocoagulation (iron and aluminum electrode) process under various conditions such as various current densities and effect of pH. Efficiencies of COD reduction, colour removal and power consumption were studied for each process. The chemical or electrochemical treatment are indented primarily to remove colour and COD of wastewater while ion exchange is used to further improve the removal efficiency of the colour, COD, Fe concentration, conductivity, alkalinity and total dissolved solids (TDS). From the results chemical coagulation, maximum COD reduction of about 81.3% was obtained at 300 mg/l of coagulant whereas in electrocoagulation process, maximum COD removal of about 92.31% (0.25 A/dm2) was achieved with energy consumption of about 19.29 k Wh/kg of COD and 80% (1A/dm(2)) COD removal was obtained with energy consumption of about 130.095 k Wh/kg of COD at iron and aluminum electrodes, respectively. All the experimental results, throughout the present study, have indicated that chemical or electrocoagulation treatment followed by ion-exchange methods were very effective and were capable of elevating quality of the treated wastewater effluent to the reuse standard of the textile industry.
NASA Astrophysics Data System (ADS)
Sun, M.; Yu, P. F.; Fu, J. X.; Ji, X. Q.; Jiang, T.
2017-08-01
The optimal process parameters and conditions for the treatment of slaughterhouse wastewater by coagulation sedimentation-AF - biological contact oxidation process were studied to solve the problem of high concentration organic wastewater treatment in the production of small and medium sized slaughter plants. The suitable water temperature and the optimum reaction time are determined by the experiment of precipitation to study the effect of filtration rate and reflux ratio on COD and SS in anaerobic biological filter and the effect of biofilm thickness and gas water ratio on NH3-N and COD in biological contact oxidation tank, and results show that the optimum temperature is 16-24°C, reaction time is 20 min in coagulating sedimentation, the optimum filtration rate is 0.6 m/h, and the optimum reflux ratio is 300% in anaerobic biological filter reactor. The most suitable biological film thickness range of 1.8-2.2 mm and the most suitable gas water ratio is 12:1-14:1 in biological contact oxidation pool. In the coupling process of continuous operation for 80 days, the average effluent’s mass concentrations of COD, TP and TN were 15.57 mg/L, 40 mg/L and 0.63 mg/L, the average removal rates were 98.93%, 86.10%, 88.95%, respectively. The coupling process has stable operation effect and good effluent quality, and is suitable for the industrial application.
Nondestructive cell evaluation techniques in SOFC stack manufacturing
NASA Astrophysics Data System (ADS)
Wunderlich, C.
2016-04-01
Independent from the specifics of the application, a cost efficient manufacturing of solid oxide fuel cells (SOFC), its electrolyte membranes and other stack components, leading to reliable long-life stacks is the key for the commercial viability of this fuel cell technology. Tensile and shear stresses are most critical for ceramic components and especially for thin electrolyte membranes as used in SOFC cells. Although stack developers try to reduce tensile stresses acting on the electrolyte by either matching CTE of interconnects and electrolytes or by putting SOFC cells under some pressure - at least during transient operation of SOFC stacks ceramic cells will experience some tensile stresses. Electrolytes are required to have a high Weibull characteristic fracture strength. Practical experiences in stack manufacturing have shown that statistical fracture strength data generated by tests of electrolyte samples give limited information on electrolyte or cell quality. In addition, the cutting process of SOFC electrolytes has a major influence on crack initiation. Typically, any single crack in one the 30 to 80 cells in series connection will lead to a premature stack failure drastically reducing stack service life. Thus, for statistical reasons only 100% defect free SOFC cells must be assembled in stacks. This underlines the need for an automated inspection. So far, only manual processes of visual or mechanical electrolyte inspection are established. Fraunhofer IKTS has qualified the method of optical coherence tomography for an automated high throughput inspection. Alternatives like laser speckle photometry and acoustical methods are still under investigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Ya; Cui, Yan; Zuo, Xiaoxi
2014-10-15
Highlights: • The spent Zn–Mn batteries collected from manufacturers is the target waste. • A facile reclaiming process is presented. • The zinc is reclaimed to valuable electrolytic zinc by electrodepositing method. • The manganese elements are to produce valuable LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} battery material. • The reclamation process features environmental friendliness and saving resource. - Abstract: A process for reclaiming the materials in spent alkaline zinc manganese dioxide (Zn–Mn) batteries collected from the manufacturers to prepare valuable electrolytic zinc and LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} materials is presented. After dismantling battery cans, the iron cans, covers, electric rods, organicmore » separator, label, sealing materials, and electrolyte are separated through the washing, magnetic separation, filtrating, and sieving operations. Then, the powder residues react with H{sub 2}SO{sub 4} (2 mol L{sup −1}) solution to dissolve zinc under a liquid/solid ratio of 3:1 at room temperature, and subsequently, the electrolytic Zn with purity of ⩾99.8% is recovered in an electrolytic cell with a cathode efficiency of ⩾85% under the conditions of 37–40 °C and 300 A m{sup −2}. The most of MnO{sub 2} and a small quantity of electrolytic MnO{sub 2} are recovered from the filtration residue and the electrodeposit on the anode of electrolytic cell, respectively. The recovered manganese oxides are used to synthesize LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} material of lithium-ion battery. The as-synthesized LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} discharges 118.3 mAh g{sup −1} capacity and 4.7 V voltage plateau, which is comparable to the sample synthesized using commercial electrolytic MnO{sub 2}. This process can recover the substances in the spent Zn–Mn batteries and innocuously treat the wastewaters, indicating that it is environmentally acceptable and applicable.« less
2012-01-01
Nanochannel arrays were fabricated by the self-organized multi-electrolyte-step anodic aluminum oxide [AAO] method in this study. The anodization conditions used in the multi-electrolyte-step AAO method included a phosphoric acid solution as the electrolyte and an applied high voltage. There was a change in the phosphoric acid by the oxalic acid solution as the electrolyte and the applied low voltage. This method was used to produce self-organized nanochannel arrays with good regularity and circularity, meaning less power loss and processing time than with the multi-step AAO method. PMID:22333268
Electrolytes for Use in High Energy Lithium-Ion Batteries with Wide Operating Temperature Range
NASA Technical Reports Server (NTRS)
Smart, Marshall C.; Ratnakumar, B. V.; West, W. C.; Whitcanack, L. D.; Huang, C.; Soler, J.; Krause, F. C.
2011-01-01
Objectives of this work are: (1) Develop advanced Li -ion electrolytes that enable cell operation over a wide temperature range (i.e., -30 to +60C). (2) Improve the high temperature stability and lifetime characteristics of wide operating temperature electrolytes. (3) Improve the high voltage stability of these candidate electrolytes systems to enable operation up to 5V with high specific energy cathode materials. (4) Define the performance limitations at low and high temperature extremes, as well as, life limiting processes. (5) Demonstrate the performance of advanced electrolytes in large capacity prototype cells.
Impact of dynamic distribution of floc particles on flocculation effect.
Nan, Jun; He, Weipeng; Song, Xinin; Li, Guibai
2009-01-01
Polyaluminum chloride (PAC) was used as coagulant and suspended particles in kaolin water. Online instruments including turbidimeter and particle counter were used to monitor the flocculation process. An evaluation model for demonstrating the impact on the flocculation effect was established based on the multiple linear regression analysis method. The parameter of the index weight of channels quantitatively described how the variation of floc particle population in different size ranges cause the decrement of turbidity. The study showed that the floc particles in different size ranges contributed differently to the decrease of turbidity and that the index weight of channel could excellently indicate the impact degree of floc particles dynamic distribution on flocculation effect. Therefore, the parameter may significantly benefit the development of coagulation and sedimentation techniques as well as the optimal coagulant selection.
Kaiser, Mohammad Rejaul; Chou, Shulei; Liu, Hua-Kun; Dou, Shi-Xue; Wang, Chunsheng; Wang, Jiazhao
2017-12-01
Electrolytes, which are a key component in electrochemical devices, transport ions between the sulfur/carbon composite cathode and the lithium anode in lithium-sulfur batteries (LSBs). The performance of a LSB mostly depends on the electrolyte due to the dissolution of polysulfides into the electrolyte, along with the formation of a solid-electrolyte interphase. The selection of the electrolyte and its functionality during charging and discharging is intricate and involves multiple reactions and processes. The selection of the proper electrolyte, including solvents and salts, for LSBs strongly depends on its physical and chemical properties, which is heavily controlled by its molecular structure. In this review, the fundamental properties of organic electrolytes for LSBs are presented, and an attempt is made to determine the relationship between the molecular structure and the properties of common organic electrolytes, along with their effects on the LSB performance. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Plutonium recovery from spent reactor fuel by uranium displacement
Ackerman, John P.
1992-01-01
A process for separating uranium values and transuranic values from fission products containing rare earth values when the values are contained together in a molten chloride salt electrolyte. A molten chloride salt electrolyte with a first ratio of plutonium chloride to uranium chloride is contacted with both a solid cathode and an anode having values of uranium and fission products including plutonium. A voltage is applied across the anode and cathode electrolytically to transfer uranium and plutonium from the anode to the electrolyte while uranium values in the electrolyte electrolytically deposit as uranium metal on the solid cathode in an amount equal to the uranium and plutonium transferred from the anode causing the electrolyte to have a second ratio of plutonium chloride to uranium chloride. Then the solid cathode with the uranium metal deposited thereon is removed and molten cadmium having uranium dissolved therein is brought into contact with the electrolyte resulting in chemical transfer of plutonium values from the electrolyte to the molten cadmium and transfer of uranium values from the molten cadmium to the electrolyte until the first ratio of plutonium chloride to uranium chloride is reestablished.
Biomaterials trigger endothelial cell activation when co-incubated with human whole blood.
Herklotz, Manuela; Hanke, Jasmin; Hänsel, Stefanie; Drichel, Juliane; Marx, Monique; Maitz, Manfred F; Werner, Carsten
2016-10-01
Endothelial cell activation resulting from biomaterial contact or biomaterial-induced blood activation may in turn also affect hemostasis and inflammatory processes in the blood. Current in vitro hemocompatibility assays typically ignore these modulating effects of the endothelium. This study describes a co-incubation system of human whole blood, biomaterial and endothelial cells (ECs) that was developed to overcome this limitation. First, human endothelial cells were characterized in terms of their expression of coagulation- and inflammation-relevant markers in response to various activators. Subsequently, their capacity to regulate hemostasis as well as complement and granulocyte activation was monitored in a hemocompatibility assay. After blood contact, quiescent ECs exhibited anticoagulant and anti-inflammatory properties. When they were co-incubated with surfaces exhibiting pro-coagulant or pro-inflammatory characteristics, the ECs down-regulated coagulation but not complement or leukocyte activation. Analysis of intracellular levels of the endothelial activation markers E-selectin and tissue factor showed that co-incubation with model surfaces and blood significantly increased the activation state of ECs. Finally, the coagulation- and inflammation-modulating properties of the ECs were tested after blood/biomaterial exposure. Pre-activation of ECs by biomaterials in the blood induced a pro-coagulant and pro-inflammatory state of the ECs, wherein the pro-coagulant response was higher for biomaterial/blood pre-activated ECs than for TNF-α-pre-activated cells. This work provides evidence that biomaterials, even without directly contacting the endothelium, affect the endothelial activation state with and have consequences for plasmatic and cellular reactions in the blood. Copyright © 2016 Elsevier Ltd. All rights reserved.
Liang, Zhongguan; Liu, Weiqing; Chen, Jun; Hu, Linhua; Dai, Songyuan
2015-01-21
After injection of electrolyte, the internal three-dimensional solid-liquid penetration system of dye-sensitized solar cells (DSCs) can take a period of time to reach "mature" state. This paper studies the changes of microscopic processes of DSCs including TiO2 energy-level movement, localized state distribution, charge accumulation, electron transport, and recombination dynamics, from the beginning of electrolyte injection to the time of reached mature state. The results show that the microscopic dynamics process of DSCs exhibited a time-dependent behavior and achieved maturity ∼12 h after injecting the electrolyte into DSCs. Within 0-12 h, several results were observed: (1) the conduction band edge of TiO2 moved slightly toward negative potential direction; (2) the localized states in the band gap of TiO2 was reduced according to the same distribution law; (3) the transport resistance in TiO2 film increased, and electron transport time was prolonged as the time of maturity went on, which indicated that the electron transport process is impeded gradually; (4) the recombination resistance at the TiO2/electrolyte (EL) interface increases, and electron lifetime gradually extends, therefore, the recombination process is continuously suppressed. Furthermore, results suggest that the parameters of EL/Pt-transparent conductive oxide (TCO) interface including the interfacial capacitance, electron-transfer resistance, and transfer time constant would change with time of maturity, indicating that the EL/Pt-TCO interface is a potential factor affecting the mature process of DSCs.
Physical analysis on laser-induced cerebral damage
NASA Astrophysics Data System (ADS)
Luo, Xiaosen; Liu, Jiangang; Tao, Chunkan; Lan, Xiufeng; Cao, Lingyan; Pan, Weimin; Shen, Zhonghua; Lu, Jian; Ni, Xiaowu
2005-01-01
Experimental investigation on cerebral damage of adult SD rats induced by 532nm CW laser was performed. Tissue heat conductive equation was set up based on two-layered structure model. Finite difference algorithm was utilized to numerically simulate the temperature distribution in the brain tissue. Allowing for tissue response to temperature variation, free boundary model was used to discuss tissue thermal coagulation formation in brain. Experimental observations show that thermal coagulation and necrosis can be caused due to laser light absorption. The result of the calculation shows that the process of the thermal coagulation of the given mode comprises two stages: fast and slow. At the first stage, necrosis domain grows fast. Then necrosis domain growth becomes slower because of the competition between the heat diffusion into the surrounding undamaged tissue and the heat dissipation caused by blood perfusion. At the center of coagulation area no neuron was observed and at the transitional zone few nervous cells were seen by microscope. The research can provide reference data for developing clinical therapy of some kind of encephalic diseases by using 532nm laser, and for making cerebral infarction models in animal experiment.
The Coagulation Profile of End-Stage Liver Disease and Considerations for Intraoperative Management.
Forkin, Katherine T; Colquhoun, Douglas A; Nemergut, Edward C; Huffmyer, Julie L
2018-01-01
The coagulopathy of end-stage liver disease results from a complex derangement in both anticoagulant and procoagulant processes. With even minor insults, cirrhotic patients experience either inappropriate bleeding or clotting, or even both simultaneously. The various phases of liver transplantation along with fluid and blood product administration may contribute to additional disturbances in coagulation. Thus, anesthetic management of patients undergoing liver transplantation to improve hemostasis and avoid inappropriate thrombosis in the perioperative environment can be challenging. To add to this challenge, traditional laboratory tests of coagulation are difficult to interpret in patients with end-stage liver disease. Viscoelastic coagulation tests such as thromboelastography (Haemonetics Corporation, Braintree, MA) and rotational thromboelastometry (TEM International, Munich, Germany) have helped to reduce transfusion of allogeneic blood products, especially fresh frozen plasma, but have also lead to the increased use of fibrinogen-containing products. In general, advancements in surgical techniques and anesthetic management have led to significant reduction in blood transfusion requirements during liver transplantation. Targeted transfusion protocols and pharmacologic prevention of fibrinolysis may further aid in the management of the complex coagulopathy of end-stage liver disease.
Lee, Naery; Seo, Ji Suk; Kim, Jae Ok; Ban, Sang Ja
2017-05-01
Since the 1st Korean national biological reference standard for factor (F)VIII concentrate, established in 2001, has shown declining potency, we conducted this study to replace this standard with a 2nd Korean national biological reference standard for blood coagulation FVIII concentrate. The candidate materials for the 2nd standard were prepared in 8000 vials with 10 IU/ml of target potency, according to the approved manufacturing process of blood coagulation Factor VIII:C Monoclonal Antibody-purified, Freeze-dried Human Blood Coagulation Factor VIII:C. Potency was evaluated by one-stage clotting and chromogenic methods and the stability was confirmed to meet the specifications during a period of 73 months. Since the potencies obtained by the two methods differed significantly (P < 0.015), the values were determined separately according to the geometric means (8.9 and 7.4 IU/vial, respectively). The geometric coefficients of interlaboratory variability were 3.4% and 7.6% by the one-stage clotting and chromogenic assays, respectively. Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Prasad, R Krishna
2009-06-15
The effects of dosage, pH and concentration of salts were investigated for an optimized condition of color removal from the distillery spent wash. The optimization process was analyzed using custom response surface methodology (RSM). The design was employed to derive a statistical model for the effect of parameters studied on removal of color using Moringa oleifera coagulant (MOC). The dosage (20 and 60 ml), pH (7 and 8.5) and concentration of 0.25 M had been found to be the optimum conditions for maximum 56% and 67% color removal using sodium chloride (NaCl) and potassium chloride (KCl) salts respectively. The actual color removal at optimal conditions was found to be 53% and 64% respectively for NaCl and KCl salts which confirms close to RSM results. The effects of storage duration and temperature on MOC studied reveal that coagulation efficiency of MOC kept at room temperature was effective for 3 days and at 4 degrees C it performed coagulation up to 5 days.
Abd Wahid, Muhamad Azhar; Megat Mohd Noor, Megat Johari; Goto, Masafumi; Sugiura, Norio; Othman, Nor'azizi; Zakaria, Zuriati; Ahmad Mohammed, Thamer; Jusoh, Ahmad; Hara, Hirofumi
2017-08-01
The natural coagulant Moringa oleifera lectin (MoL) as cationic protein is a promising candidate in coagulation process of water treatment plant. Introducing the gene encoding MoL into a host, Pichia pastoris, to secrete soluble recombinant protein is assessed in this study. Initial screening using PCR confirmed the insertion of MoL gene, and SDS-PAGE analysis detected the MoL protein at 8 kDa. Cultured optimization showed the highest MoL protein at 520 mg/L was observed at 28 °C for 144 h of culturing by induction in 1% methanol. Approximately, 0.40 mg/mL of recombinant MoL protein showed 95 ± 2% turbidity removal of 1% kaolin suspension. In 0.1% kaolin suspension, the concentration of MoL at 10 μg/mL exhibits the highest turbidity reduction at 68 ± 1%. Thus, recombinant MoL protein from P. pastoris is an effective coagulant for water treatment.
Zeng, Yubin; Yang, Changzhu; Zhang, Jingdong; Pu, Wenhong
2007-08-25
Poly-zinc silicate (PZSS) is a new type of coagulant with cationic polymer synthesized by polysilicic acid and zinc sulfate. It has been used in several sorts of wastewaters treatment, but not used in oily wastewater treatment. In this study, we investigated the coagulation/flocculation of oil and suspended solids in heavy oil wastewater (HOW) by PZSS and anion polyacrylamide (A-PAM). The properties of PZSS cooperated with A-PAM were compared with PAC and PFS in dosages, PAMs amount, settling time, pH value and flocs morphology. The results showed that PZSS was more efficient than PAC and PFS. Under the optimum experimental conditions of coagulation/flocculation (dosage: 100mg/L, A-PAM dosage: 1.0mg/L, settling time time: 40min and pH 6.5-9.5), more than 99% of oil was removed and suspended solid value less than 5mg/L by using PZSS cooperated with A-PAM, which could satisfy the demands of the pre-treatment process for HOW to be reused in the steam boiler or recycled into the injecting well.
Effect of Dust Coagulation Dynamics on the Geometry of Aggregates
NASA Technical Reports Server (NTRS)
Nakamura, R.
1996-01-01
Master equation gives a more fundamental description of stochastic coagulation processes rather than popular Smoluchowski's equation. In order to examine the effect of the dynamics on the geometry of resulting aggregates, we study Master equation with a rigorous Monte Carlo algorithm. It is found that Cluster-Cluster aggregation model is a good approximation of orderly growth and the aggregates have fluffy structures with a fractal dimension approx. 2. A scaling analysis of Smoluchowski's equation also supports this conclusion.
Electrochemistry of the Hall-Heroult Process for Aluminum Smelting.
ERIC Educational Resources Information Center
Haupin, W. E.
1983-01-01
Nearly all aluminum is produced by the electrolysis of alumina dissolved in a molten cryolite-based electrolyte, the Hall-Heroult Process. Various aspects of the procedure are discussed, focusing on electrolyte chemistry, dissolution of alumina, electrode reactions, current efficiency, and cell voltage. Suggestions for graduate study related to…
Ewen, D; Clarke, S L; Smith, J R; Berger, C; Salmon, G; Trevethick, M; Shute, J K
2010-03-01
We recently reported that repair following mechanical wounding of epithelial cell layers in vitro is dependent on fibrin formation and the activity of locally expressed coagulation cascade proteins. Serine proteases of the coagulation cascade are an important group of protease-activated receptor (PAR) activators and PAR-1 to 4 are expressed by the normal bronchial epithelium. We tested the hypothesis that activation of PAR-1 and PAR-2 by coagulation cascade proteases stimulates epithelial repair via effects on fibrin formation. Using mechanically wounded 16HBE 14o(-) epithelial cell layers in culture, we investigated the effect of PAR-1 and PAR-2 agonist peptides, control partially scrambled peptides and PAR-neutralizing antibodies on the rate of repair and fibrin formation. Coagulation factors in culture supernatants were measured by immunoblot. RT-PCR was used to investigate PAR-1, PAR-2 and PGE2 receptor (EP-1 to EP-4) expression in this model and qRT-PCR to quantify responses to wounding. Additionally, we investigated the effect of exogenously added factor Xa (FXa) and neutrophil elastase and the influence of PGE2 and indomethacin on the repair response. PAR-1 and PAR-2 peptide agonists stimulated the rate of repair and enhanced the formation of a fibrin provisional matrix to support the repair process. Conversely, PAR-neutralizing antibodies inhibited repair. Under serum-free culture conditions, 16HBE 14o(-) cells expressed EP-2 and EP-3, but not EP-1 or EP-4, receptors. Wounding induced an increased expression of EP-3 but did not alter EP-2, PAR-1 or PAR-2 expression. In the absence of PAR agonists, there was no evidence for a role for PGE2 in fibrin formation or the repair process. Indomethacin attenuated fibrin formation in wounded cultures only in the presence of the PAR-2 peptide. FXa stimulated epithelial repair while neutrophil elastase reduced the levels of coagulation factors and inhibited repair. Locally expressed serine proteases of the coagulation cascade activate PAR-1 and PAR-2 to enhance fibrin formation and bronchial epithelial repair.
Light emission from organic single crystals operated by electrolyte doping
NASA Astrophysics Data System (ADS)
Matsuki, Keiichiro; Sakanoue, Tomo; Yomogida, Yohei; Hotta, Shu; Takenobu, Taishi
2018-03-01
Light-emitting devices based on electrolytes, such as light-emitting electrochemical cells (LECs) and electric double-layer transistors (EDLTs), are solution-processable devices with a very simple structure. Therefore, it is necessary to apply this device structure into highly fluorescent organic materials for future printed applications. However, owing to compatibility problems between electrolytes and organic crystals, electrolyte-based single-crystal light-emitting devices have not yet been demonstrated. Here, we report on light-emitting devices based on organic single crystals and electrolytes. As the fluorescent materials, α,ω-bis(biphenylyl)terthiophene (BP3T) and 5,6,11,12-tetraphenylnaphthacene (rubrene) single crystals were selected. Using ionic liquids as electrolytes, we observed clear light emission from BP3T LECs and rubrene EDLTs.
NASA Astrophysics Data System (ADS)
Khazaeli, Ali; Vatani, Ali; Tahouni, Nassim; Panjeshahi, Mohammad Hassan
2015-10-01
In flow batteries, electrolyte flow rate plays a crucial role on the minimizing mass transfer polarization which is at the compensation of higher pressure drop. In this work, a two-dimensional numerical method is applied to investigate the effect of electrolyte flow rate on cell voltage, maximum depth of discharge and pressure drop a six-cell stack of VRFB. The results show that during the discharge process, increasing electrolyte flow rate can raise the voltage of each cell up to 50 mV on average. Moreover, the maximum depth of discharge dramatically increases with electrolyte flow rate. On the other hand, the pressure drop also positively correlates with electrolyte flow rate. In order to investigate all these effects simultaneously, average energy and exergy efficiencies are introduced in this study for the transient process of VRFB. These efficiencies give insight into choosing an appropriate strategy for the electrolyte flow rate. Finally, the energy efficiency of electricity storage using VRFB is investigated and compared with other energy storage systems. The results illustrate that this kind of battery has at least 61% storage efficiency based on the second law of thermodynamics, which is considerably higher than that of their counterparts.
Xiong, Zhaokun; Cao, Jinyan; Yang, Dan; Lai, Bo; Yang, Ping
2017-01-01
A coagulation-flocculation as pre-treatment combined with mFe/Cu/O 3 (CF-mFe/Cu/O 3 ) process was developed to degrade the pollutants in automobile coating wastewater (ACW). In coagulation-flocculation (CF) process, high turbidity removal efficiency (97.1%) and low COD removal efficiency (10.5%) were obtained under the optimal conditions using Al 2 (SO 4 ) 3 ·18H 2 O and CaO. The effluent of CF process (ECF) was further disposed by mFe/Cu/O 3 process, and its key operating parameters were optimized by batch experiments. Optimally, COD removal efficiency of ECF obtained by the mFe/Cu/O 3 process (i.e., 87.6% after 30 min treatment) was much higher than those of mFe/Cu alone (8.3%), ozone alone (46.6%), and mFe/Cu/air (6.1%), which confirms the superiority of the mFe/Cu/O 3 process. In addition, the analysis results of UV-vis, excitation-emission matrix (EEM) fluorescence spectra and GC/MS further confirm that the phenol pollutants of ECF had been effectively decomposed or transformed after CF-mFe/Cu/O 3 process treatment. Meanwhile, B/C ratio of ACW increased from 0.19 to 0.56, which suggests the biodegradability was improved significantly. Finally, the operating cost of CF-mFe/Cu/O 3 process was about 1.83 USD t -1 for ACW treatment. Therefore, the combined process is a promising treatment technology for the coating wastewater from automobile manufacturing. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comprehensive reuse of drinking water treatment residuals in coagulation and adsorption processes.
Jung, Kyung-Won; Hwang, Min-Jin; Park, Dae-Seon; Ahn, Kyu-Hong
2016-10-01
While drinking water treatment residuals (DWTRs) inevitably lead to serious problems due to their huge amount of generation and limitation of landfill sites, their unique properties of containing Al or Fe contents make it possible to reuse them as a beneficial material for coagulant recovery and adsorbent. Hence, in the present study, to comprehensively handle and recycle DWTRs, coagulant recovery from DWTRs and reuse of coagulant recovered residuals (CRs) were investigated. In the first step, coagulant recovery from DWTRs was conducted using response surface methodology (RSM) for statistical optimization of independent variables (pH, solid content, and reaction time) on response variable (Al recovery). As a result, a highly acceptable Al recovery of 97.5 ± 0.4% was recorded, which corresponds to 99.5% of the predicted Al recovery. Comparison study of recovered and commercial coagulant from textile wastewater treatment indicated that recovered coagulant has reasonable potential for use in wastewater treatment, in which the performance efficiencies were 68.5 ± 2.1% COD, 97.2 ± 1.9% turbidity, and 64.3 ± 1.0% color removals at 50 mg Al/L. Subsequently, in a similar manner, RSM was also applied to optimize coagulation conditions (Al dosage, initial pH, and reaction time) for the maximization of real cotton textile wastewater treatment in terms of COD, turbidity, and color removal. Overall performance revealed that the initial pH had a remarkable effect on the removal performance compared to the effects of other independent variables. This is mainly due to the transformation of metal species form with increasing or decreasing pH conditions. Finally, a feasibility test of CRs as adsorbent for phosphate adsorption from aqueous solution was conducted. Adsorption equilibrium of phosphate at different temperatures (10-30 °C) and initial levels of pH (3-11) indicated that the main mechanisms of phosphate adsorption onto CRs are endothermic and chemical precipitation; the surfaces are energetically heterogeneous for adsorbing phosphate. Copyright © 2016 Elsevier Ltd. All rights reserved.
Formation of iron metal and grain coagulation in the solar nebula
NASA Technical Reports Server (NTRS)
Nuth, Joseph A., III; Berg, Otto
1994-01-01
The interstellar grain population in the giant molecular cloud from which the sun formed contained little or no iron metal. However, thermal processing of individual interstellar silicates in the solar nebula is likely to result in the formation of a population of very small iron metal grains. If such grains are exposed to even transient magnetic fields, each will become a tiny dipole magnet capable of interacting with other such dipoles over spatial scale orders of magnitude larger than the radii of individual grains. Such interactions will greatly increase the coagulation cross-section for this grain population. Furthermore, the magnetic attraction between two iron dipoles will significantly increase both the collisional sticking coefficient and the strength of the interparticle binding energy for iron aggregates. Formation of iron metal may therefore be a key step in the aggregation of planetesimals in a protoplanetary nebula. Such aggregates may have already been observed in protoplanetary systems. The enhancement in the effective interaction distance between two magnetic dipoles is directly proportional to the strength of the magnetic dipoles and inversely proportional to the relative velocity. It is less sensitive to the reduced mass of the interacting particles (alpha M(exp -1/2)) and almost insensitive to the initial number density of magnetic dipoles (alpha n(sub o)(exp 1/6)). We are in the process of measuring the degree of coagulation in our condensation flow apparatus as a function of applied magnetic field and correlating these results by means of magnetic remanance acquisition measurements on our iron grains with the strength of the magnetic field to which the grains are exposed. Results of our magnetic remanance acquisition measurements and the magnetic-induced coagulation study will be presented as well as an estimate of the importance of such processes near the nebular midplane.
NASA Astrophysics Data System (ADS)
Liu, Q. L.; Fu, C. J.; Chan, S. H.; Pasciak, G.
2011-06-01
In this study, a co-tape casting and co-sintering process has been developed to prepare yttria-stabilized zirconia (YSZ) electrolyte films supported on Ni-YSZ anode substrates in order to substantially reduce the fabrication cost of solid oxide fuel cells (SOFC). Through proper control of the process, the anode/electrolyte bilayer structures with a size of 7.8cm × 7.8cm were achieved with good flatness. Scanning electron microscopy (SEM) observation indicated that the YSZ electrolyte film was about 16 μm in thickness, highly dense, crack free and well-bonded to the anode support. The electrochemical properties of the prepared anode-supported electrolyte film was evaluated in a button cell mode incorporating a (LaSr)MnO3-YSZ composite cathode. With humidified hydrogen as the fuel and stationary air as the oxidant, the cell demonstrated an open-circuit voltage of 1.081 V and a maximum power density of 1.01 W/cm2 at 800°C. The obtained results represent the important progress in the development of anode-supported intermediate temperature SOFC with reduced fabrication cost.
Hu, Chengzhi; Liu, Huijuan; Chen, Guixia; Jefferson, William A; Qu, Jiuhui
2012-06-19
An electrochemically prepared water treatment reagent containing a high concentration of Al(13) polymer and active chlorine (PACC) showed promising potential for the removal of As(III) due to the combined function of oxidation and coagulation. The results indicated that PACC was effective for As(III) removal through oxidation by the active chlorine and subsequent removal of As(V) by coagulation with the Al(13) polymer. The As(III) was oxidized to As(V) by active chlorine in PACC, with a stoichiometric rate of 0.99 mg Cl(2)/mg As(III). The Al(13) polymer was the most active Al species responsible for As(V) removal in PACC. To meet As drinking water standards the stoichiometric weight ratio of Cl(2)/Al within PACC was 0.09 for the treatment of As(III). Considering the process of As(III) oxidation and As(V) coagulation together, the optimal pH conditions for the removal of As by PACC was within the neutral range, which facilitated the reaction of As(III) with active chlorine and favored the formation of Al hydroxide flocs. The presence of humic acid reduced the As(III) removal efficiency of PACC due to its negative influence on subsequent As(V) coagulation, and disinfection byproduct yields were very low in the presence of insufficient or stoichiometric active chlorine.
Fogelson, Aaron L; Tania, Nessy
2005-01-01
A mathematical model of intravascular coagulation is presented; it encompasses the biochemistry of the tissue factor pathway, platelet activation and deposition on the subendothelium, and flow- and diffusion-mediated transport of coagulation proteins and platelets. Simulation experiments carried out with the model indicate the predominant role played by the physical processes of platelet deposition and flow-mediated removal of enzymes in inhibiting coagulation in the vicinity of vascular injury. Sufficiently rapid production of factors IXa and Xa by the TF:VIIa complex can overcome this inhibition and lead to formation of significant amounts of the tenase complex on the surface of activated platelets and, as a consequence, to substantial thrombin production. Chemical inhibitors are seen to play almost no (TFPI) or little (AT-III and APC) role in determining whether substantial thrombin production will occur. The role of APC is limited by the necessity for diffusion of thrombin from the site of injury to nearby endothelial cells to form the thrombomodulin-thrombin complex and for diffusion in the reverse direction of the APC made by this complex. TFPI plays an insignificant part in inhibiting the TF:VIIa complex under the conditions studied whether its action involves sequential binding of TFPI to Xa and then TFPI:Xa to TF:VIIa, or direct binding of TFPI to Xa already bound to the TF:VIIa complex. Copyright 2005 S. Karger AG, Basel.
Alavi, Mehrosadat; Totonchi, Alireza; Okhovat, Mohammad Ali; Motazedian, Motahareh; Rezaei, Peyman; Atefi, Mohammad
2014-12-01
In recent years, a wide variety of research has been carried out in the field of novel technologies to stop severe bleeding. In several studies, coagulation properties of minerals such as zeolite, bentonite and halloysite have been proven. In this study, the effect of a new impregnated sterile gauze containing bentonite and halloysite minerals was studied on blood coagulation and wound healing rate in male Wistar rats. Initially, impregnated sterile gauze was prepared from the mixture of bentonite and halloysite minerals and petroleum jelly (Vaseline). Then, the effect of gauze was studied on the blood coagulation time and wound healing process in 40 Wistar rats. SPSS software was used for data analysis and P values less than 0.05 were considered significant. The coagulation time of 81.10 ± 2.532 s in the control group and 33.00 ± 1.214 s in the study group (bentonite-halloysite treated) were reported (P < 0.0005). Time for complete wound healing in the group, which is treated with impregnated sterile pads, was calculated approximately from 10 to 12 days. However, in the control group, there was no complete wound healing (P < 0.0005). According to the results of the present study, topical application of the bentonite-halloysite impregnated sterile gauze significantly decreases the clotting time and increase the wound healing rate.
di Stasio, Stefano; Konstandopoulos, Athanasios G; Kostoglou, Margaritis
2002-03-01
The agglomeration kinetics of growing soot generated in a diffusion atmospheric flame are here studied in situ by light scattering technique to infer cluster morphology and size (fractal dimension D(f) and radius of gyration R(g)). SEM analysis is used as a standard reference to obtain primary particle size D(P) at different residence times. The number N(P) of primary particles per aggregate and the number concentration n(A) of clusters are evaluated on the basis of the measured angular patterns of the scattered light intensity. The major finding is that the kinetics of the coagulation process that yields to the formation of chain-like aggregates by soot primary particles (size 10 to 40 nm) can be described with a constant coagulation kernel beta(c,exp)=2.37x10(-9) cm3/s (coagulation constant tau(c) approximately = 0.28 ms). This result is in nice accord with the Smoluchowski coagulation equation in the free molecular regime, and, vice versa, it is in contrast with previous studies conducted by invasive (ex situ) techniques, which claimed the evidence in flames of coagulation rates much larger than the kinetic theory predictions. Thereafter, a number of numerical simulations is implemented to compare with the experimental results on primary particle growth rate and on the process of aggregate reshaping that is observed by light scattering at later residence times. The restructuring process is conjectured to occur, for not well understood reasons, as a direct consequence of the atomic rearrangement in the solid phase carbon due to the prolonged residence time within the flame. Thus, on one side, it is shown that the numerical simulations of primary size history compare well with the values of primary size from SEM experiment with a growth rate constant of primary diameter about 1 nm/s. On the other side, the evolution of aggregate morphology is found to be predictable by the numerical simulations when the onset of a first-order "thermal" restructuring mechanism is assumed to occur in the flame at about 20 ms residence time leading to aggregates with an asymptotic fractal dimension D(f,infinity) approximately = 2.5.
Solid electrolyte material manufacturable by polymer processing methods
Singh, Mohit; Gur, Ilan; Eitouni, Hany Basam; Balsara, Nitash Pervez
2012-09-18
The present invention relates generally to electrolyte materials. According to an embodiment, the present invention provides for a solid polymer electrolyte material that is ionically conductive, mechanically robust, and can be formed into desirable shapes using conventional polymer processing methods. An exemplary polymer electrolyte material has an elastic modulus in excess of 1.times.10.sup.6 Pa at 90 degrees C. and is characterized by an ionic conductivity of at least 1.times.10.sup.-5 Scm-1 at 90 degrees C. An exemplary material can be characterized by a two domain or three domain material system. An exemplary material can include material components made of diblock polymers or triblock polymers. Many uses are contemplated for the solid polymer electrolyte materials. For example, the present invention can be applied to improve Li-based batteries by means of enabling higher energy density, better thermal and environmental stability, lower rates of self-discharge, enhanced safety, lower manufacturing costs, and novel form factors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hui; Chen, Yan; Hood, Zachary D.
All-solid-state sodium batteries, using abundant sodium resources and solid electrolyte, hold much promise for safe, low cost, large-scale energy storage. To realize the practical applications of all solid Na-ion batteries at ambient temperature, the solid electrolytes are required to have high ionic conductivity, chemical stability, and ideally, easy preparation. Ceramic electrolytes show higher ionic conductivity than polymers, but they often require extremely stringent synthesis conditions, either high sintering temperature above 1000 C or long-time, low-energy ball milling. Herein, we report a new synthesis route for Na 3SbS 4, a novel Na superionic conductor that needs much lower processing temperature belowmore » 200 C and easy operation. This new solid electrolyte exhibits a remarkable ionic conductivity of 1.05 mS cm -1 at 25 °C and is chemically stable under ambient atmosphere. In conclusion, this synthesis process provides unique insight into the current state-of-the-art solid electrolyte preparation and opens new possibilities for the design of similar materials.« less
Purely electronic mechanism of electrolyte gating of indium tin oxide thin films
Leng, X.; Bozovic, I.; Bollinger, A. T.
2016-08-10
Epitaxial indium tin oxide films have been grown on both LaAlO 3 and yttria-stabilized zirconia substrates using RF magnetron sputtering. Electrolyte gating causes a large change in the film resistance that occurs immediately after the gate voltage is applied, and shows no hysteresis during the charging/discharging processes. When two devices are patterned next to one another and the first one gated through an electrolyte, the second one shows no changes in conductance, in contrast to what happens in materials (like tungsten oxide) susceptible to ionic electromigration and intercalation. These findings indicate that electrolyte gating in indium tin oxide triggers amore » pure electronic process (electron depletion or accumulation, depending on the polarity of the gate voltage), with no electrochemical reactions involved. Electron accumulation occurs in a very thin layer near the film surface, which becomes highly conductive. These results contribute to our understanding of the electrolyte gating mechanism in complex oxides and may be relevant for applications of electric double layer transistor devices.« less
NASA Astrophysics Data System (ADS)
de la Torre-Gamarra, Carmen; Appetecchi, Giovanni Battista; Ulissi, Ulderico; Varzi, Alberto; Varez, Alejandro; Passerini, Stefano
2018-04-01
Ceramic electrolytes are prepared through sintering processes which are carried out at high temperatures and require prolonged operating times, resulting unwelcome in industrial applications. We report a physicochemical characterization on hybrid, sodium conducting, electrolyte systems obtained by coating NASICON ceramic powders with the N-butyl-N-methylpyrrolidinium bis(trifluoromethanesulfonyl)imide ionic liquid. The goal is to realize a ceramic-IL interface with improved sodium mobility, aiming to obtain a solid electrolyte with high ion transport properties but avoiding sintering thermal treatment. The purpose of the present work, however, is showing how simply combining NASICON powder and Py14TFSI does not lead to any synergic effect on the resulting hybrid electrolyte, evidencing that an average functionalization of the ceramic powder surface and/or ionic liquid is needed. Also, the processing conditions for preparing the hybrid samples are found to affect their ion transport properties.
InGaN/GaN quantum dots as optical probes for the electric field at the GaN/electrolyte interface
NASA Astrophysics Data System (ADS)
Teubert, J.; Koslowski, S.; Lippert, S.; Schäfer, M.; Wallys, J.; Dimitrakopulos, G.; Kehagias, Th.; Komninou, Ph.; Das, A.; Monroy, E.; Eickhoff, M.
2013-08-01
We investigated the electric-field dependence of the photoluminescence-emission properties of InGaN/GaN quantum dot multilayers in contact with an electrolyte. Controlled variations of the surface potential were achieved by the application of external electric fields using the electrolytic Schottky contact and by variation of the solution's pH value. Prior to characterization, a selective electrochemical passivation process was required to suppress leakage currents. The quantum dot luminescence is strongly affected by surface potential variations, i.e., it increases exponentially with cathodic bias and acidic pH values. The results cannot be explained by a modification of intra-dot polarization induced electric fields via the quantum confined Stark effect but are attributed to the suppression/enhancement of non-radiative recombination processes, i.e., mainly hole transfer into the electrolyte. The results establish a link between the photoluminescence intensity and the magnitude of electric fields at the semiconductor/electrolyte interface.
Phosphatidylserine in atherosclerosis.
Darabi, Maryam; Kontush, Anatol
2016-08-01
It is now widely acknowledged that phosphatidylserine is a multifunctional bioactive lipid. In this review, we focus on the function of phosphatidylserine in modulating cholesterol metabolism, influencing inflammatory response and regulating coagulation system, and discuss promising phosphatidylserine-based therapeutic approaches and detection techniques in atherosclerosis. Phosphatidylserine has been suggested to play important roles in physiological processes, such as apoptosis, inflammation, and coagulation. Recent data demonstrate atheroprotective potential of phosphatidylserine, reflecting its capacity to inhibit inflammation, modulate coagulation, and enhance HDL functionality. Furthermore, modern lipidomic approaches have enabled the investigation of phosphatidylserine properties relevant to the lipid-based drug delivery and development of reconstituted HDL. Studies of phosphatidylserine in relation to atherosclerosis represent an area of opportunity. Additional research elucidating mechanisms underlying experimentally observed atheroprotective effects of phosphatidylserine is required to fully explore therapeutic potential of this naturally occurring phospholipid in cardiovascular disease.
Momeni, Meysam Mohammad; Kahforoushan, Davood; Abbasi, Farhang; Ghanbarian, Saeid
2018-04-01
One of the most important solid-liquid separation processes is coagulation and flocculation that is extensively used in the primary treatment of industrial wastewater. The biopolymers, because of biodegradable properties and low cost have been used as coagulants. In this study, chitosan as a natural coagulant of choice, was modified by (3-chloro 2-hydroxypropyl)trimethylammonium chloride and was used to remove the color and turbidity of industrial wastewater. To evaluate the effect of pH, settling time, the initial turbidity of wastewater, the amount of coagulant, and the concentration of dye (Melanoidin) were chosen to study their effects on removal of wastewater color and turbidity. The experiments were done in a batch system by using a jar test. To achieve the optimum conditions for the removal of color and turbidity, the response surface methodology (RSM) experimental design method was used. The results obtained from experiments showed that the optimum conditions for the removal of color were as: pH = 3, concentration of dye = 1000 mg/L, settling time = 78.93 min, and dose of coagulant = 3 g/L. The maximum color removal in these conditions was predicted 82.78% by the RSM model. The optimal conditions for the removal of turbidity of the waste water were as: pH = 5.66, initial turbidity = 60 NTU, settling time = 105 min, and amount of coagulant = 3 g/L. The maximum turbidity removal in these circumstances was predicted 94.19% by the model. The experimental results obtained in optimum conditions for removal of color and turbidity were 76.20% and 90.14%, respectively, indicating the high accuracy of the prediction model. Copyright © 2018 Elsevier Ltd. All rights reserved.
Treatment of landfill leachate using a combined stripping, Fenton, SBR, and coagulation process.
Guo, Jin-Song; Abbas, Abdulhussain A; Chen, You-Peng; Liu, Zhi-Ping; Fang, Fang; Chen, Peng
2010-06-15
The leachate from Changshengqiao landfill (Chongqing, China) was characterized and submitted to a combined process of air stripping, Fenton, sequencing batch reactor (SBR), and coagulation. Optimum operating conditions for each process were identified. The performance of the treatment was assessed by monitoring the removal of organic matter (COD and BOD(5)) and ammonia nitrogen (NH(3)-N). It has been confirmed that air stripping (at pH 11.0 and aeration time 18h) effectively removed 96.6% of the ammonia. The Fenton process was investigated under optimum conditions (pH 3.0, FeSO(4).7H(2)O of 20 g l(-1) and H(2)O(2) of 20 ml l(-1)), COD removal of up to 60.8% was achieved. Biodegradability (BOD(5)/COD ratio) increased from 0.18 to 0.38. Thereafter the Fenton effluent was mixed with sewage at dilutions to a ratio of 1:3 before it was subjected to the SBR reactor; under the optimum aeration time of 20 h, up to 82.8% BOD(5) removal and 83.1% COD removal were achieved. The optimum coagulant (Fe(2)(SO(4))(3)) was a dosage of 800 mg l(-1) at pH of 5.0, which reduced COD to an amount of 280 mg l(-1). These combined processes were successfully employed and very effectively decreased pollutant loading. Crown Copyright 2010. Published by Elsevier B.V. All rights reserved.
Ying, Diwen; Peng, Juan; Xu, Xinyan; Li, Kan; Wang, Yalin; Jia, Jinping
2012-08-30
A comparative study of treating mature landfill leachate with various treatment processes was conducted to investigate whether the method of combined processes of internal micro-electrolysis (IME) without aeration and IME with full aeration in one reactor was an efficient treatment for mature landfill leachate. A specifically designed novel sequencing batch internal micro-electrolysis reactor (SIME) with the latest automation technology was employed in the experiment. Experimental data showed that combined processes obtained a high COD removal efficiency of 73.7 ± 1.3%, which was 15.2% and 24.8% higher than that of the IME with and without aeration, respectively. The SIME reactor also exhibited a COD removal efficiency of 86.1 ± 3.8% to mature landfill leachate in the continuous operation, which is much higher (p<0.05) than that of conventional treatments of electrolysis (22.8-47.0%), coagulation-sedimentation (18.5-22.2%), and the Fenton process (19.9-40.2%), respectively. The innovative concept behind this excellent performance is a combination effect of reductive and oxidative processes of the IME, and the integration electro-coagulation. Optimal operating parameters, including the initial pH, Fe/C mass ratio, air flow rate, and addition of H(2)O(2), were optimized. All results show that the SIME reactor is a promising and efficient technology in treating mature landfill leachate. Copyright © 2012 Elsevier B.V. All rights reserved.
Chon, Kangmin; Cho, Jaeweon; Kim, Seung Joon; Jang, Am
2014-12-01
A pilot study was conducted to assess the performance of a municipal wastewater reclamation plant consisting of a combined coagulation-disk filtration (CC-DF) process, microfiltration (MF) and reverse osmosis (RO) membranes, in terms of the removal of water contaminants and changes in characteristics of effluent organic matter (EfOM). The CC-DF and MF membranes were not effective for the removal of dissolved water contaminants. However, they could partially reduce the turbidity associated with the cake layer formation by particulate materials on the membrane surfaces. Furthermore, most of water contaminants were completely removed by the RO membranes. Although the CC-DF process could remove approximately 20% of turbidity, the aluminium concentrations considerably increased after the CC-DF process due to the residual coagulants complexed with both carboxylic acid and alcohol functional groups of EfOM. Those aluminium-EfOM complexes had a lower negative charge and higher molecular weight (>0.1 μm pore size of the MF membranes) compared to non-complexed EfOM. These results indicate that the control of the formation of the aluminium-EfOM complexes should be considered as a key step to use the CC-DF process as a pre-treatment of the MF and RO membranes for mitigation of membrane fouling in the tested pilot plant. Copyright © 2014 Elsevier Ltd. All rights reserved.
Yong, Zi Jun; Bashir, Mohammed J K; Ng, Choon Aun; Sethupathi, Sumathi; Lim, Jun-Wei
2018-01-01
The increase in landfill leachate generation is due to the increase of municipal solid waste (MSW) as global development continues. Landfill leachate has constantly been the most challenging issue in MSW management as it contains high amount of organic and inorganic compounds that might cause pollution to water resources. Biologically treated landfill leachate often fails to fulfill the regulatory discharge standards. Thus, to prevent environmental pollution, many landfill leachate treatment plants involve multiple stages treatment process. The Papan Landfill in Perak, Malaysia currently has no proper leachate treatment system. In the current study, sequential treatment via sequencing batch reactor (SBR) followed by coagulation was used to treat chemical oxygen demand (COD), ammoniacal nitrogen (NH 3 -N), total suspended solids (TSS), and colour from raw landfill leachate. SBR optimum aeration rate, L/min, optimal pH and dosage (g/L) of Alum for coagulation as a post-treatment were determined. The two-step sequential treatment by SBR followed by coagulation (Alum) achieved a removal efficiency of 84.89%, 94.25%, 91.82% and 85.81% for COD, NH 3 -N, TSS and colour, respectively. Moreover, the two-stage treatment process achieved 95.0% 95.0%, 95.3%, 100.0%, 87.2%, 62.9%, 50.0%, 41.3%, 41.2, 34.8, and 22.9 removals of Cadmium, Lead, Copper, Selenium, Barium, Iron, Silver, Nickel, Zinc, Arsenic, and Manganese, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mancini, Giuseppe; Panzica, Michele; Fino, Debora; Cappello, Simone; Yakimov, Michail M; Luciano, Antonella
2017-12-01
In the present study, chemical oxygen demand (COD) removal by coagulation and packed-columns of both fresh and bioregenerated granular activated carbon (GAC) is reported as a feasible treatment for saline and oily wastewaters (slops) generated from marine oil tankers cleaning. The use of Ferric chloride (FeCl 3 ), Aluminium sulphate (Al 2 (SO 4 ) 3 ) and Polyaluminum chloride (Al 2 (OH 3 )Cl 3 ) was evaluated in the pre-treatment by coagulation of a real slop, after a de-oiling phase in a tank skimmer Comparison of coagulation process indicated that Polyaluminum chloride and Aluminium sulphate operate equally well (20-30% of COD removal) when applied at their optimal dose (40 and 90 mg/l respectively) but the latter should be preferred in order to significantly control the sludge production. The results from the column filtration tests indicated the feasibility of using the selected GAC (Filtrasorb 400 -Calgon Carbon Corporation) to achieve the respect of the discharge limits in the slops treatment with a carbon usage rate in the range 0.1-0.3 kg/m 3 of treated effluent. Moreover, biological regeneration through Alcalinovorax borkumensis SK2 was proved to be a cost-effective procedure since the reuse of spent GAC through such regeneration process for further treatment could still achieve approximately 90% of the initial sorption capacity, reducing then costs for the use of new sorbents and also the need for waste disposal. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhou, Zhiwei; Yang, Yanling; Li, Xing; Ji, Siyang; Zhang, Hao; Wang, Shuai; Zeng, Qingping; Han, Xinghang
2016-01-01
To clarify the role of solubilized organics derived from drinking water treatment sludge (DWTS) in the elimination of natural organic matter (NOM) in the DWTS recycling process, a probe sonoreactor at a frequency of 25 kHz was used to solubilize the organics at varied specific energies. The coagulation behavior related to NOM removal in recycling the sonicated DWTS with and without solubilized organics was evaluated, and the effect on organic fractionations in coagulated water was determined. The study results could provide useful implications in designing DWTS recycling processes that avoid the enrichment of organic matter. Our results indicate that DWTS was disrupted through a low release of soluble chemical oxygen demand (SCOD) and proteins, which could deteriorate the coagulated water quality under the specific energy of 37.87-1212.1 kW h/kg TS. The optimal coagulation behavior for NOM removal was achieved by recycling the sonicated DWTS without solubilized organics at 151.5 kW h/kg TS specific energy. Recycling the sonicated DWTS could increase the enrichment potential of weakly hydrophobic acid, hydrophilic matter, and <3 kDa fractions; the enrichment risks could be reduced by discharging the solubilized organics. Fluorescent characteristic analysis indicated that when recycling the sonicated DWTS without solubilized organics, the removal of humic-like substances was limited, whereas removal of protein-like substances was enhanced, lowering the enrichment potential of protein-like substances. Copyright © 2015. Published by Elsevier B.V.
Ganapathy, Swapna; van Eck, Ernst R H; Kentgens, Arno P M; Mulder, Fokko M; Wagemaker, Marnix
2011-12-23
The power density of lithium-ion batteries requires the fast transfer of ions between the electrode and electrolyte. The achievable power density is directly related to the spontaneous equilibrium exchange of charged lithium ions across the electrolyte/electrode interface. Direct and unique characterization of this charge-transfer process is very difficult if not impossible, and consequently little is known about the solid/liquid ion transfer in lithium-ion-battery materials. Herein we report the direct observation by solid-state NMR spectroscopy of continuous lithium-ion exchange between the promising nanosized anatase TiO(2) electrode material and the electrolyte. Our results reveal that the energy barrier to charge transfer across the electrode/electrolyte interface is equal to or greater than the barrier to lithium-ion diffusion through the solid anatase matrix. The composition of the electrolyte and in turn the solid/electrolyte interface (SEI) has a significant effect on the electrolyte/electrode lithium-ion exchange; this suggests potential improvements in the power of batteries by optimizing the electrolyte composition. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ELECTROLYTIC SEPARATION PROCESS AND APPARATUS
McLain, M.E. Jr.; Roberts, M.W.
1962-03-01
A method is given for dissolving stainless steel-c lad fuel elements in dilute acids such as half normal sulfuric acid. The fuel element is made the anode in a Y-shaped electrolytic cell which has a flowing mercury cathode; the stainless steel elements are entrained in the mercury and stripped therefrom by a continuous process. (AEC)
Process for electrolytically preparing uranium metal
Haas, Paul A.
1989-01-01
A process for making uranium metal from uranium oxide by first fluorinating uranium oxide to form uranium tetrafluoride and next electrolytically reducing the uranium tetrafluoride with a carbon anode to form uranium metal and CF.sub.4. The CF.sub.4 is reused in the fluorination reaction rather than being disposed of as a hazardous waste.
Electrically conductive anodized aluminum coatings
NASA Technical Reports Server (NTRS)
Alwitt, Robert S. (Inventor); Liu, Yanming (Inventor)
2001-01-01
A process for producing anodized aluminum with enhanced electrical conductivity, comprising anodic oxidation of aluminum alloy substrate, electrolytic deposition of a small amount of metal into the pores of the anodized aluminum, and electrolytic anodic deposition of an electrically conductive oxide, including manganese dioxide, into the pores containing the metal deposit; and the product produced by the process.
Process for electrolytically preparing uranium metal
Haas, Paul A.
1989-08-01
A process for making uranium metal from uranium oxide by first fluorinating uranium oxide to form uranium tetrafluoride and next electrolytically reducing the uranium tetrafluoride with a carbon anode to form uranium metal and CF.sub.4. The CF.sub.4 is reused in the fluorination reaction rather than being disposed of as a hazardous waste.
Marobhe, N J; Dalhammar, G; Gunaratna, K R
2007-06-01
The coagulating properties of aqueous crude extracts and purified proteins of Vigna unguiculata and Parkinsonia aculeata seeds, which are traditional water coagulants in rural areas of Tanzania, were studied. The coagulation activity assays were done using one millilitre (ml) of kaolin water samples. Coagulating proteins were purified in two-step ion exchange chromatography. The properties of coagulant protein were compared with Moringa oleifera. Coagulating components eluted by 0.6 M NaCl in both coagulants are cationic proteins that have the molecular mass of about 6 kDa, which is very similar to that of M. oleifera. The proteins of V. unguiculata and P. aculeata eluted by 0.3 M NaCl also harbour coagulation activity but proteins eluted with 0.6 M NaCl have higher activity. The dosage for coagulation using purified proteins of both coagulants is about 5 to 10 times lower than that of crude seed extracts. The optimum floc settling time of water treated by crude seed extracts and purified proteins ranged between two and two and half hours. Coagulating proteins of both coagulants eluted by 0.6 M NaCl are thermoresistant and retained coagulation activity of 87% to 92% after boiling for two hours at 80 degrees C and one hour at 95 degrees C. Thermotolerant proteins of V. unguiculata eluted by 0.6 M NaCl and P. aculeata have wider pH range of 5.5 to 8.5 for coagulation activity than those of M. oleifera proteins. The present investigation reveals the possibility of using purified natural coagulants for water treatment to produce safe drinking water.
Electrolytic pretreatment unit gaseous effluent conditioning
NASA Technical Reports Server (NTRS)
Colombo, G. V.; Putnam, D. F.
1976-01-01
The electrolytic pretreatment of urine is an advanced process that eliminates the need for handling and storing the highly corrosive chemicals that are normally used in water reclamation systems. The electrolytic pretreatment process also converts the organic materials in urine to gases (N2 and O2) that can be used to replenish those lost to space by leakage, venting, and air lock operations. The electrolytic process is more than a pretreatment, since it decreases the urine solids content by approximately one third, thus reducing the load and eventual solids storage requirements of the urine processing system. The evolved gases from the pretreatment step cannot, however, be returned directly to the atmosphere of a spacecraft without first removing several impurities including hydrogen, chlorine, and certain organic compounds. A treatment concept was developed that would decrease the impurities in the gas stream that emanates from an electrolysis unit to levels sufficiently low to allow the conditioned gas stream to be safely discharged to a spacecraft atmosphere. Two methods were experimentally demonstrated that can accomplish the desired cleanup. The bases of the two methods are, repectively: (1) raw urine scrubbing and (2) silica gel sorption.
Zhu, Guocheng; Wang, Chuang; Dong, Xingwei
2017-06-01
Landfill leachate contains a variety of organic matters, some of which can be excited and emit fluorescence signal. In order to degrade these organic matters, the pretreatment of the leachate is needed, which can improve the degradation performance of post-treatment process. Coagulation-flocculation is one of the important pretreatment processes to treat landfill leachate. Assessing the chemical compositions of landfill leachate is helpful in the understanding of their sources and fates as well as the mechanistic behaviors in the water environment. The present work aimed to use fluorescence excitation-emission matrix spectroscopy (EEMs) to characterize the chemical fractions of landfill leachate dissolved organic matter (DOM) in conjunction with parallel factor analysis (PARAFAC). Results showed that the DOM of landfill leachate tested in this study was identified resulting from microbial input, which included five typical characteristic peaks and four kinds of PARAFAC fractions. These fractions were mainly composed of hydrophobic macromolecule humic acid-like (HM-HA), hydrophilic intermediate molecular fulvic acid-like (HIM-FA), and hydrophilic small molecule protein-like substances (HSM-PS). HM-HA and HIM-FA were found to be easier to remove than HSM-PS. Further research on HSM-PS removal by coagulation-flocculation still needs to be improved.
Rochael, Natalia Cadaxo; Lima, Luize Gonçalves; de Oliveira, Sandra Maria Pereira; Barcinski, Marcello André; Saraiva, Elvira Maria; Monteiro, Robson Queiroz; Pinto-da-Silva, Lucia Helena
2013-01-01
Leishmania parasites expose phosphatidylserine (PS) on their surface, a process that has been associated with regulation of host's immune responses. In this study we demonstrate that PS exposure by metacyclic promastigotes of Leishmania amazonensis favours blood coagulation. L. amazonensis accelerates in vitro coagulation of human plasma. In addition, L. amazonensis supports the assembly of the prothrombinase complex, thus promoting thrombin formation. This process was reversed by annexin V which blocks PS binding sites. During blood meal, Lutzomyia longipalpis sandfly inject saliva in the bite site, which has a series of pharmacologically active compounds that inhibit blood coagulation. Since saliva and parasites are co-injected in the host during natural transmission, we evaluated the anticoagulant properties of sandfly saliva in counteracting the procoagulant activity of L. amazonensis . Lu. longipalpis saliva reverses plasma clotting promoted by promastigotes. It also inhibits thrombin formation by the prothrombinase complex assembled either in phosphatidylcholine (PC)/PS vesicles or in L. amazonensis . Sandfly saliva inhibits factor X activation by the intrinsic tenase complex assembled on PC/PS vesicles and blocks factor Xa catalytic activity. Altogether our results show that metacyclic promastigotes of L. amazonensis are procoagulant due to PS exposure. Notably, this effect is efficiently counteracted by sandfly saliva. PMID:24037188
Xing, Zi-Peng; Sun, De-Zhi
2009-09-15
Attempts were made in this study to examine the combined polyferric sulfate (PFS) coagulation, Fenton and sedimentation process for treatment of non-degradable antibiotic fermentation wastewater. The experimental results indicated that 66.6% of color and 72.4% of chemical oxygen demand (COD) were removed under the optimum conditions of PFS dosage 200mg/L and pH 4.0. In addition, optimal parameters of Fenton process were determined to be 150 mg/L of H(2)O(2) dosage, 120 mg/L of FeSO(4) and 1h of reaction time. When Fenton treated effluent was controlled at pH 7.0, the pollutants could be further removed by sedimentation process. The overall color, COD and suspended solids (SS) removal reached 97.3%, 96.9% and 86.7% under selected conditions, respectively. Thus this study might offer an effective way for wastewater treatment of antibiotics manufacturer and pharmaceutical industry.
Plutonium recovery from spent reactor fuel by uranium displacement
Ackerman, J.P.
1992-03-17
A process is described for separating uranium values and transuranic values from fission products containing rare earth values when the values are contained together in a molten chloride salt electrolyte. A molten chloride salt electrolyte with a first ratio of plutonium chloride to uranium chloride is contacted with both a solid cathode and an anode having values of uranium and fission products including plutonium. A voltage is applied across the anode and cathode electrolytically to transfer uranium and plutonium from the anode to the electrolyte while uranium values in the electrolyte electrolytically deposit as uranium metal on the solid cathode in an amount equal to the uranium and plutonium transferred from the anode causing the electrolyte to have a second ratio of plutonium chloride to uranium chloride. Then the solid cathode with the uranium metal deposited thereon is removed and molten cadmium having uranium dissolved therein is brought into contact with the electrolyte resulting in chemical transfer of plutonium values from the electrolyte to the molten cadmium and transfer of uranium values from the molten cadmium to the electrolyte until the first ratio of plutonium chloride to uranium chloride is reestablished.
Preventing Corrosion by Controlling Cathodic Reaction Kinetics
2016-03-25
electrochemical reaction rates of processes that drive corrosion, e.g. the oxygen reduction reaction (ORR). To this end, we have used reactive...elements on the kinetics of oxygen reduction reaction catalyzed on titanium oxide in order to develop new approaches for controlling galvanic corrosion... consumption of anions in reactions with metal cations can deplete the electrolyte. However, in the atmospheric electrolyte, the electrolyte
NASA Astrophysics Data System (ADS)
Vickraman, P.; Gopukumar, S.
2017-07-01
The PVC/PVdF-co-HFP composite polymer electrolyte membranes (CPEMs) by varying blend ratios 1:1, 1:2, and 2:1 with fixed content of Al2O3, TiO2 and SiO2 having soaked in 0.5 M LiPF6 in EC/DEC (1:1) v/v) have been prepared by phase inversion. CPEMs of higher ionic conductivity (not dependent on electrolyte uptake as observed in our study) ASA4 (3.61×10-4 Scm-1), TSA3 (1.53×10-4 Scm-1), and SSA3 (4.81×10-4 Scm-1) have been only chosen for XRD, DSC, SEM and electrochemical studies. In XRD, crystalline peaks (phases) of PVdF have been noted with/without change in intensity as well as FWHM which correspond to type of filler interaction with host matrix. In DSC, it is observed that shifts in baseline, melting endotherms, and area under the endotherms indicating the thermal hist ory of PVC (Tg = 82 ° C) and melting of VdF crystallites varied with nature of the filler dispersoid. In SEM, the coagulated fibrils of the polymer coiled with the sponge like structure has been mapped. The charge/discharge studies are carried out on these CPEMs at C/10 rate in the voltage range 2.8 V - 4.2 V, and it is noted that the TSA3 showed better cycling performance with good capacity retention i.e., 50 cycles with 66% capacity retention than ASA4 of 28 cycles with 65% and SSA3 of 5 cycles with 56%. In the present study Coulombic efficiency is concerned only for first cycle and it is noted that the TSA3 showed 71% than 66% and 62% respectively for SSA3 and ASA4.
Method and system for the removal of oxides of nitrogen and sulfur from combustion processes
Walsh, John V.
1987-12-15
A process for removing oxide contaminants from combustion gas, and employing a solid electrolyte reactor, includes: (a) flowing the combustion gas into a zone containing a solid electrolyte and applying a voltage and at elevated temperature to thereby separate oxygen via the solid electrolyte, (b) removing oxygen from that zone in a first stream and removing hot effluent gas from that zone in a second stream, the effluent gas containing contaminant, (c) and pre-heating the combustion gas flowing to that zone by passing it in heat exchange relation with the hot effluent gas.
van Hengel, Ingmar A J; Riool, Martijn; Fratila-Apachitei, Lidy E; Witte-Bouma, Janneke; Farrell, Eric; Zadpoor, Amir A; Zaat, Sebastian A J; Apachitei, Iulian
2017-08-01
Additively manufactured Ti-6Al-4V implants were biofunctionalized using plasma electrolytic oxidation. At various time points during this process scanning electron microscopy imaging was performed to analyze the surface morphology (van Hengel et al., 2017) [1]. This data shows the changes in surface morphology during plasma electrolytic oxidation. Data presented in this article are related to the research article "Selective laser melting porous metallic implants with immobilized silver nanoparticles kill and prevent biofilm formation by methicillin-resistant Staphylococcus aureus" (van Hengel et al., 2017) [1].
Otaki, Yoichi; Ebana, Yusuke; Yoshikawa, Shunji; Isobe, Mitsuaki
2016-09-01
Intravascular thrombus formation causes various cardiovascular diseases. To monitor coagulation is important for screening native status, prevention from bleeding and maintaining it within its therapeutic range. The prothrombin time and the activated partial thromboplastin time are widely used for assessment and recognized as the conventional methods. Prothrombin time methods employ enhancement of coagulation with thromboplastin. Since the laboratory data depend on the production lot and/or the manufacturer, the accurate methods are required for evaluation. Rotational thromboelastometry (ROTEM) is a method based on detection of the change in resistance to rotational movement during blood clotting, while dielectric blood coagulometry (DBCM) is a novel method for assessment of clotting by measuring the change of electrical permittivity. These methods are thus based on the technology for observation of different physical phenomena. The aim of this study was to compare parameters such as the clotting time obtained by ROTEM and DBCM to evaluate their clinical usefulness. ROTEM and DBCM parameters were measured in 128 patients. The ROTEM clotting time showed a significant positive correlation with the DBCM coagulation time (R=0.707, p<0.001). Comparison of the DBCM coagulation time between patients with and without anticoagulant therapy (including novel oral anticoagulants) revealed a significant difference (43.8±11.9min in the anticoagulant group vs 29.4±8.3min in the control group, p<0.001). Evaluation of coagulation was equivalent with DBCM and ROTEM. The present study suggested that DBCM, a novel method for measuring blood clotting, could provide the detail assessment for the status of anticoagulant therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.
Functionalization of single-walled carbon nanotubes regulates their effect on hemostasis
NASA Astrophysics Data System (ADS)
Sokolov, A. V.; Aseychev, A. V.; Kostevich, V. A.; Gusev, A. A.; Gusev, S. A.; Vlasova, I. I.
2011-04-01
Applications of single-walled carbon nanotubes (SWNTs) in medical field imply the use of drug-coupled carbon nanotubes as well as carbon nanotubes functionalized with different chemical groups that change nanotube surface properties and interactions between nanotubes and cells. Covalent attachment of polyethylene glycol (PEG) to carboxylated single-walled carbon nanotubes (c-SWNT) is known to prevent the nanotubes from interaction with macrophages. Here we characterized nanotube's ability to stimulate coagulation processes in platelet-poor plasma (PPP), and evaluated the effect of SWNTs on platelet aggregation in platelet-rich plasma (PRP). Our study showed that PEG-SWNT did not affect the rate of clotting in PPP, while c-SWNT shortened the clot formation time five times compared to the control PPP. Since c-SWNT failed to accelerate coagulation in plasma lacking coagulation factor XI, it may be suggested that c-SWNT affects the contact activation pathway. In PRP, platelets responded to both SWNT types with irreversible aggregation, as evidenced by changes in the aggregate mean radius. However, the rate of aggregation induced by c-SWNT was two times higher than it was with PEG-SWNT. Cytological analysis also showed that c-SWNT was two times more efficient when compared to PEG-SWNT in aggregating platelets in PRP. Taken together, our results show that functionalization of nanoparticles can diminish their negative influence on blood cells. As seen from our data, modification of c-SWNT with PEG, when only a one percent of carbon atoms is bound to polymer (70 wt %), decreased the nanotube-induced coagulation in PRP and repelled the accelerating effect on the coagulation in PPP. Thus, when functionalized SWNTs are used for administration into bloodstream of laboratory animals, their possible pro-coagulant and pro-aggregating properties must be taken into account.
Zhang, Ying; Zhang, Ning; Zhao, Peng; Niu, Zhiguang
2018-03-01
The characteristics of dissolved organic matter (DOM) and bromide ion concentration have a significant influence on the formation of disinfection by-products (DBPs). In order to identify the main DBP precursors, DOM was divided into five fractions based on molecular weight (MW), trihalomethane formation potential and haloacetic acid formation potential were determined for fractions, and the change in contents of different fractions and total DBPs during treatment processes (pre-chlorination, coagulation, sand filtration, disinfection) were studied. Moreover, the relationship between bromide concentration and DBP generation characteristics in processes was also analyzed. The results showed that the main DBP precursors were the fraction with MW <1kDa and fraction with MW 3-10kDa, and the DBP's generation ability of lower molecular weight DOM (<10kDa) was higher than that of higher molecular weight DOM. During different processes, pre-chlorination and disinfection had limited effect on removing organics but could alter the MW distribution, and coagulation and filtration could effectively remove organics with higher MW. For DBPs, trihalomethanes (THMs) were mainly generated in pre-chlorination and disinfection, while haloacetic acids (HAAs) were mostly generated during pre-chlorination; coagulation and sand filtration had little effect on THMs but resulted in a slight removal of HAAs. In addition, the results of ANOVA tests suggested that molecular sizes and treatment processes have significant influence on DBP formation. With increasing bromide concentration, the brominated DBPs significantly increased, but the bromine incorporation factor in the processes was basically consistent at each concentration. Copyright © 2017. Published by Elsevier B.V.
Exploring electrolyte preference of vanadium nitride supercapacitor electrodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Bo; Chen, Zhaohui; Lu, Gang
Highlights: • Hierarchical VN nanostructures were prepared on graphite foam. • Electrolyte preference of VN supercapacitor electrodes was explored. • VN showed better capacitive property in organic and alkaline electrolytes than LiCl. - Abstract: Vanadium nitride hierarchical nanostructures were prepared through an ammonia annealing procedure utilizing vanadium pentoxide nanostructures grown on graphite foam. The electrochemical properties of hierarchical vanadium nitride was tested in aqueous and organic electrolytes. As a result, the vanadium nitride showed better capacitive energy storage property in organic and alkaline electrolytes. This work provides insight into the charge storage process of vanadium nitride and our findings canmore » shed light on other transition metal nitride-based electrochemical energy storage systems.« less
Accumulation of Contaminants in the Distribution System.
Removal of arsenic from water using iron-related processes including coagulation with iron salts, iron removal with oxidation/filtration, and specific iron resins is established. These processes are effective because iron solids including minerals and chemical floc have strong ad...
Administration of tissue plasminogen activator without coagulation results in a Chinese population.
Qin, Xiaoming; Zhao, Songyao; Yin, Liujie; Dou, Hailing; Chen, Jie; Wang, Yifan; Li, Mingzhe; Chen, Ruifang; Fu, Jing; Liu, Wei; Liu, Xin; Yang, Gaiqing; Wang, Runqing; Jia, Xinzhou; Bu, Shufang; Ma, Dongpu; Wang, Baoyu; Li, Shize
2018-03-01
Routine coagulation test before intravenous tissue plasminogen activator (tPA) use increases the door to needle time (DNT). We sought to evaluate the safety of tPA use without coagulation results and its impact on prognosis. In our stroke registry, tPA was delivered with coagulation results from December 2015 to April 2016 and without coagulation results from May 2016 to December 2016. Differences of demographics, clinical characteristic, and prognosis between these two groups were analyzed. In addition, logistic regression analysis was conducted to identify predictors for DNT of over 60 min. A total of 201 stroke patients were included in the final analysis. Of these, 81 patients received tPA with coagulation results and 120 patients without coagulation results. Only one (0.8%) patient with abnormal coagulation results met the exclusion criteria of tPA use in patients without coagulation results. The difference of DNT between groups with (mean, 61.7 min) and without (mean, 41.9 min) coagulation results was significant (P = 0.00). The group without coagulation results had a higher rate of favorable 90-day outcome (74.2 vs 70.4%) and lower rates of symptomatic intracranial hemorrhage/nonintracranial hemorrhage (4.9 and 22.2% vs 1.7 and 19.2%) than the group with coagulation results did; these differences were not statistically significant. In multivariate analysis, only tPA use with coagulation results was the predictor for DNT of over 60 min (P = 0.0030, OR = 2.44, 95% CI 1.28-4.65). The present study suggests that tPA could be delivered safely without coagulation results in patients without suspected coagulopathy, and avoiding coagulation tests reduces significantly the DNT interval.
2013-01-01
Environmental impact assessment will soon become a compulsory phase in future potable water production projects, in algeria, especially, when alternative treatment processes such sedimentation ,coagulation sand filtration and Desinfection are considered. An impact assessment tool is therefore developed for the environmental evaluation of potable water production. in our study The evaluation method used is the life cycle assessment (LCA) for the determination and evaluation of potential impact of a drink water station ,near algiers (SEAL-Boudouaoua). LCA requires both the identification and quantification of materials and energy used in all stages of the product’s life, when the inventory information is acquired, it will then be interpreted into the form of potential impact “ eco-indicators 99” towards study areas covered by LCA, using the simapro6 soft ware for water treatment process is necessary to discover the weaknesses in the water treatment process in order for it to be further improved ensuring quality life. The main source shown that for the studied water treatment process, the highest environmental burdens are coagulant preparation (30% for all impacts), mineral resource and ozone layer depletion the repartition of the impacts among the different processes varies in comparison with the other impacts. Mineral resources are mainly consumed during alumine sulfate solution preparation; Ozone layer depletion originates mostly from tetrachloromethane emissions during alumine sulfate production. It should also be noted that, despite the small doses needed, ozone and active Carbone treatment generate significant impacts with a contribution of 10% for most of the impacts. Moreover impacts of energy are used in producing pumps (20-25 GHC) for plant operation and the unitary processes (coagulation, sand filtration decantation) and the most important impacts are localized in the same equipment (40-75 GHC) and we can conclude that: – Pre-treatment, pumping and EDR (EDR: 0.-6 0 kg CO2 eq. /produced m3) are the process-units with higher environmental impacts. – Energy consumption is the main source of impacts on climate change. – Chemicals consumption (e.g. coagulants, oxidants) are the principle cause of impacts on the ozone layer depletion. – Conventional plants: pre-treatment has high GHG emissions due to chemicals consumption. PMID:24355378
Health effects of desalinated water: Role of electrolyte disturbance in cancer development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nriagu, Jerome, E-mail: jnriagu@umich.edu
This review contends that “healthy” water in terms of electrolyte balance is as important as “pure” water in promoting public health. It considers the growing use of desalination (demineralization) technologies in drinking water treatment which often results in tap water with very low concentrations of sodium, potassium, magnesium and calcium. Ingestion of such water can lead to electrolyte abnormalities marked by hyponatremia, hypokalemia, hypomagnesemia and hypocalcemia which are among the most common and recognizable features in cancer patients. The causal relationships between exposure to demineralized water and malignancies are poorly understood. This review highlights some of the epidemiological and inmore » vivo evidence that link dysregulated electrolyte metabolism with carcinogenesis and the development of cancer hallmarks. It discusses how ingestion of demineralized water can have a procarcinogenic effect through mediating some of the critical pathways and processes in the cancer microenvironment such as angiogenesis, genomic instability, resistance to programmed cell death, sustained proliferative signaling, cell immortalization and tumorigenic inflammation. Evidence that hypoosmotic stress-response processes can upregulate a number of potential oncogenes is well supported by a number studies. In view of the rising production and consumption of demineralized water in most parts of the world, there is a strong need for further research on the biological importance and protean roles of electrolyte abnormalities in promoting, antagonizing or otherwise enabling the development of cancer. The countries of the Gulf Cooperative Council (GCC) where most people consume desalinated water would be a logical place to start this research. - Highlights: • Ingestion of low-mineral waters disrupts electrolyte homeostasis and cellular processes. • Electrolyte imbalance can affect the tumor microenvironment and many stages of tumorigenesis. • Electrolyte disturbance is frequently encountered in patients with malignancies. • Desalinated water consumption and cancer rates are rising in Persian Gulf countries “Balanced water” can be as important as balanced diet in safeguarding our health.« less
Spectroscopic investigation of plasma electrolytic borocarburizing on q235 low-carbon steel
NASA Astrophysics Data System (ADS)
Liu, Run; Wang, Bin; Wu, Jie; Xue, Wenbin; Jin, Xiaoyue; Du, Jiancheng; Hua, Ming
2014-12-01
A plasma electrolytic borocarburizing process (PEB/C) in borax electrolyte with glycerin additive was employed to fabricate a hardening layer on Q235 low-carbon steel. Optical emission spectroscopy (OES) was utilized to investigate the spectroscopy characteristics of plasma discharge around the steel during PEB/C process. Some plasma parameters were calculated in terms of OES. The electron temperature and electron concentration in plasma discharge zone is about 3000-12,000 K and 2 × 1022 m-3-1.4 × 1023 m-3. The atomic ionization degrees of iron, carbon and boron are 10-16-10-3, and 10-23-10-6, 10-19-10-4, respectively, which depend on discharge time. The surface morphology and cross-sectional microstructure of PEB/C hardening layer were observed, and the electrolyte decomposition and plasma discharge behaviors were discussed.
Magsonic™ Carbothermal Technology Compared with the Electrolytic and Pidgeon Processes
NASA Astrophysics Data System (ADS)
Prentice, Leon H.; Haque, Nawshad
A broad technology comparison of carbothermal magnesium production with present technologies has not been previously presented. In this paper a comparative analysis of CSIRO's MagSonic™ process is made with the electrolytic and Pidgeon processes. The comparison covers energy intensity (GJ/tonne Mg), labor intensity (person-hours/tonne Mg), capital intensity (USD/tonne annual Mg installed capacity), and Global Warming Potential (GWP, tonnes CO2-equivalent/tonne Mg). Carbothermal technology is advantageous on all measures except capital intensity (where it is roughly twice the capital cost of a similarly-sized Pidgeon plant). Carbothermal and electrolytic production can have comparatively low environmental impacts, with typical emissions one-sixth those of the Pidgeon process. Despite recent progress, the Pidgeon process depends upon abundant energy and labor combined with few environmental constraints. Pressure is expected to increase on environmental constraints and labor and energy costs over the coming decade. Carbothermal reduction technology appears to be competitive for future production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mikhailovich, S.M.
Subcutaneous introduction of polonium to dogs brings about development of radiation sickness with appearance of haemorrhagic syndrome, which is characterized by disturbed process of blood coagulation, thrombocytopenia, decreased prothrombin value of the blood, increased permeability of capillaries. The clinical picture of the usually developed affection corresponds to the well known symptomatology, described in literature. Indicators of the haemorrhagic syndrome (blood coagulation, prothrombin value, permeabillty and stability of capillaries) appear in animals earlier than the clinical manifestations of this syndrome. (tr-auth)
Kang, Yoo Goo; Martin, Douglas J.; Marquez, Jose; Lewis, Jessica H.; Bontempo, Franklin A.; Shaw, Byers W.; Starzl, Thomas E.; Winter, Peter M.
2010-01-01
The blood coagulation system of 66 consecutive patients undergoing consecutive liver transplantations was monitored by thrombelastograph and analytic coagulation profile. A poor preoperative coagulation state, decrease in levels of coagulation factors, progressive fibrinolysis, and whole blood clot lysis were observed during the preanhepatic and anhepatic stages of surgery. A further general decrease in coagulation factors and platelets, activation of fibrinolysis, and abrupt decrease in levels of factors V and VIII occurred before and with reperfusion of the homograft. Recovery of blood coagulability began 30–60 min after reperfusion of the graft liver, and coagulability had returned toward baseline values 2 hr after reperfusion. A positive correlation was shown between the variables of thrombelastography and those of the coagulation profile. Thrombelastography was shown to be a reliable and rapid monitoring system. Its use was associated with a 33% reduction of blood and fluid infusion volume, whereas blood coagulability was maintained without an increase in the number of blood product donors. PMID:3896028
Study on electrochemically deposited Mg metal
NASA Astrophysics Data System (ADS)
Matsui, Masaki
An electrodeposition process of magnesium metal from Grignard reagent based electrolyte was studied by comparing with lithium. The electrodeposition of magnesium was performed at various current densities. The obtained magnesium deposits did not show dendritic morphologies while all the lithium deposits showed dendritic products. Two different crystal growth modes in the electrodeposition process of magnesium metal were confirmed by an observation using scanning electron micro scope (SEM) and a crystallographic analysis using X-ray diffraction (XRD). An electrochemical study of the deposition/dissolution process of the magnesium showed a remarkable dependency of the overpotential of magnesium deposition on the electrolyte concentration compared with lithium. This result suggests that the dependency of the overpotential on the electrolyte concentration prevent the locally concentrated current resulting to form very uniform deposits.
Evolution of phospholipid contents during the production of quark cheese from buttermilk.
Ferreiro, T; Martínez, S; Gayoso, L; Rodríguez-Otero, J L
2016-06-01
We report the evolution of phosphatidylethanolamine (PE), phosphatidylinositol (PI), phosphatidylcholine (PC), phosphatidylserine (PS), and sphingomyelin (SM) contents during the production of quark cheese from buttermilk by successive ultrafiltration concentration, enrichment with cream, concurrent homogenization and pasteurization, fermentative coagulation, and separation of quark from whey by further ultrafiltration. Buttermilk is richer than milk itself in phospholipids that afford desirable functional and technological properties, and is widely used in dairy products. To investigate how phospholipid content is affected by end-product production processes such as ultrafiltration, homogenization, pasteurization or coagulation, we measured the phospholipids at several stages of each of 5 industrial-scale quark cheese production runs. In each run, 10,000L of buttermilk was concentrated to half volume by ultrafiltration, enriched with cream, homogenized, pasteurized, inoculated with lactic acid bacteria, incubated to coagulation, and once more concentrated to half volume by ultrafiltration. Phospholipid contents were determined by HPLC with evaporative light scattering detection in the starting buttermilk, concentrated buttermilk, ultrafiltrate, cream-enriched concentrated buttermilk (both before and after concurrent homogenization and pasteurization), coagulate, and quark, and also in the rinsings obtained when the ultrafiltration equipment was washed following initial concentration. The average phospholipid content of buttermilk was approximately 5 times that of milk, and the phospholipid content of buttermilk fat 26 to 29 times that of milk fat. Although phospholipids did not cross ultrafiltration membranes, significant losses occurred during ultrafiltration (due to retention on the membranes) and during the homogenization and pasteurization process. During coagulation, however, phospholipid content rose, presumably as a consequence of the proliferation of the inoculated lactic acid bacteria. In spite of these changes in total phospholipid content, the relative proportions of the phospholipids studied remain fairly stable throughout quark production (PE>PC>SM>PS>PI) and similar to those found in the milk of the region, except that SM content was lower than in milk. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Titania nanotube powders obtained by rapid breakdown anodization in perchloric acid electrolytes
NASA Astrophysics Data System (ADS)
Ali, Saima; Hannula, Simo-Pekka
2017-05-01
Titania nanotube (TNT) powders are prepared by rapid break down anodization (RBA) in a 0.1 M perchloric acid (HClO4) solution (Process 1), and ethylene glycol (EG) mixture with HClO4 and water (Process 2). A study of the as-prepared and calcined TNT powders obtained by both processes is implemented to evaluate and compare the morphology, crystal structure, specific surface area, and the composition of the nanotubes. Longer TNTs are formed in Process 1, while comparatively larger pore diameter and wall thickness are obtained for the nanotubes prepared by Process 2. The TNTs obtained by Process 1 are converted to nanorods at 350 °C, while nanotubes obtained by Process 2 preserve tubular morphology till 350 °C. In addition, the TNTs prepared by an aqueous electrolyte have a crystalline structure, whereas the TNTs obtained by Process 2 are amorphous. Samples calcined till 450 °C have XRD peaks from the anatase phase, while the rutile phase appears at 550 °C for the TNTs prepared by both processes. The Raman spectra also show clear anatase peaks for all samples except the as-prepared sample obtained by Process 2, thus supporting the XRD findings. FTIR spectra reveal the presence of O-H groups in the structure for the TNTs obtained by both processes. However, the presence is less prominent for annealed samples. Additionally, TNTs obtained by Process 2 have a carbonaceous impurity present in the structure attributed to the electrolyte used in that process. While a negligible weight loss is typical for TNTs prepared from aqueous electrolytes, a weight loss of 38.6% in the temperature range of 25-600 °C is found for TNTs prepared in EG electrolyte (Process 2). A large specific surface area of 179.2 m2 g-1 is obtained for TNTs prepared by Process 1, whereas Process 2 produces nanotubes with a lower specific surface area. The difference appears to correspond to the dimensions of the nanotubes obtained by the two processes.
Polymer Electrolyte Through Enzyme Catalysis for High Performance Lithium-Ion Batteries
1998-10-16
by block number) FIELD GROUP SUB-GROUP Polymer Electrolyte, Solid State, Enzyme Catalysis, Lithium - Ion Battery , Sol Gel, High Conductivity 19...excellent candidates for lithium - ion battery development. Furthermore, the processes used to achieve the final product yield very good mechanical properties...Objectives This research was initiated to investigate synthesis of improved polymer electrolytes for lithium - ion battery applications. The overall
Blood coagulation status of small-for-dates and postmature infants.
Perlman, M; Dvilansky, A
1975-01-01
In a prospective study of blood coagulation status in small-for-dates and postmature infants there was often evidence of intravascular coagulation. Abnormal coagulation findings correlated with the degree of growth retardation and with the degree of postmaturity. Macroscopical placental infarction and neonatal polycythaemia were associated with coagulation abnormalities; asphyxia, however, was not. Intravascular coagulation may be an additional hazard to small-for-dates and postmature infants. PMID:1170815
Wang, Xiaomeng; Li, Minghui; Song, Xiaojie; Chen, Zhihao; Wu, Bingdang; Zhang, Shujuan
2016-09-06
The nontoxicity of titanium (Ti) and the potential to produce valuable photocatalysts from the final coagulated sludge constitute the main advantages of Ti-based coagulants over conventional ones. However, the low effluent pH and the too-fast hydrolysis limit the wide application of Ti-salt coagulants. Prehydrolysis, to some extent, is helpful to improve the coagulation performance of Ti-salt coagulants. However, the prehydrolyzed polytitanium chloride (PTC) still suffers from narrow applicable dose/pH range. A novel and efficient Ti-based coagulant, denoted as titanium xerogel coagulant (TXC), was successfully prepared by the sol-gel method with TiCl4 as the precursor and acetylacetone as a modifying agent. Compared with TiCl4, a PTC, and a commercial polyferric sulfate, the resulting TXC possessed a larger floc size, better settling property, and wider applicable coagulant dose/pH range. Moreover, the effluent pH after TXC coagulation was not significantly reduced, avoiding the corrosion problem sometimes caused by the low effluent pH. TXC exhibited good coagulation performance for several real wastewaters, especially for the wastewaters of low turbidity. These results demonstrate that gelation was a more effective strategy than prehydrolysis to overcome the inherent weaknesses of Ti salts as a type of promising coagulants.
NASA Astrophysics Data System (ADS)
Dong, Siqun; Zhao, Dianli
2018-01-01
This paper studies the subcritical, near-critical and supercritical asymptotic behavior of a reversible random coagulation-fragmentation polymerization process as N → ∞, with the number of distinct ways to form a k-clusters from k units satisfying f(k) =(1 + o (1)) cr-ke-kαk-β, where 0 < α < 1 and β > 0. When the cluster size is small, its distribution is proved to converge to the Gaussian distribution. For the medium clusters, its distribution will converge to Poisson distribution in supercritical stage, and no large clusters exist in this stage. Furthermore, the largest length of polymers of size N is of order ln N in the subcritical stage under α ⩽ 1 / 2.
The use of waterworks sludge for the treatment of vegetable oil refinery industry wastewater.
Basibuyuk, M; Kalat, D G
2004-03-01
Water treatment works using coagulation/flocculation in the process stream will generate a waste sludge. This sludge is termed as ferric, alum, or lime sludge based on which coagulant was primarily used. The works in Adana, Turkey uses ferric chloride. The potential for using this sludge for the treatment of vegetable oil refinery industry wastewater by coagulation has been investigated. The sludge acted as a coagulant and excellent oil and grease, COD and TSS removal efficiencies were obtained. The optimum conditions were a pH of 6 and a sludge dose of 1100 mg SS l(-1). The efficiency of sludge was also compared with alum and ferric chloride for the vegetable oil refinery wastewater. At doses of 1300-1900 mg SS l(-1), the sludge was as effective as ferric chloride and alum at removing oil and grease, COD, and TSS. In addition, various combinations of ferric chloride and waterworks sludge were also examined. Under the condition of 12.5 mg l(-1) fresh ferric chloride and 1000 mg SS l(-1) sludge dose, 99% oil and grease 99% TSS and 83% COD removal efficiencies were obtained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kotalczyk, G., E-mail: Gregor.Kotalczyk@uni-due.de; Kruis, F.E.
Monte Carlo simulations based on weighted simulation particles can solve a variety of population balance problems and allow thus to formulate a solution-framework for many chemical engineering processes. This study presents a novel concept for the calculation of coagulation rates of weighted Monte Carlo particles by introducing a family of transformations to non-weighted Monte Carlo particles. The tuning of the accuracy (named ‘stochastic resolution’ in this paper) of those transformations allows the construction of a constant-number coagulation scheme. Furthermore, a parallel algorithm for the inclusion of newly formed Monte Carlo particles due to nucleation is presented in the scope ofmore » a constant-number scheme: the low-weight merging. This technique is found to create significantly less statistical simulation noise than the conventional technique (named ‘random removal’ in this paper). Both concepts are combined into a single GPU-based simulation method which is validated by comparison with the discrete-sectional simulation technique. Two test models describing a constant-rate nucleation coupled to a simultaneous coagulation in 1) the free-molecular regime or 2) the continuum regime are simulated for this purpose.« less
Zhao, Y X; Shon, H K; Phuntsho, S; Gao, B Y
2014-02-15
This study is the first attempt to investigate the effect of total hardness and ionic strength on coagulation performance and the floc characteristics of titanium tetrachloride (TiCl4). Membrane fouling under different total hardness and ionic strength conditions was also evaluated during a coagulation-ultrafiltration (C-UF) hybrid process. Coagulation experiments were performed with two simulated waters, using humic acid (HA, high molecular weight) and fulvic acid (FA, relatively low molecular weight), respectively, as model natural organic matter (NOM). Results show that both particle and organic matter removal can be enhanced by increasing total hardness and ionic strength. Floc characteristics were significantly influenced by total hardness and ionic strength and were improved in terms of floc size, growth rate, strength, recoverability and compactness. The results of the UF tests show that the pre-coagulation with TiCl4 significantly improves the membrane permeate fluxes. Under different total hardness and ionic strength conditions, the membrane permeate flux varied according to both NOM and floc characteristics. The increase in total hardness and ionic strength improved the membrane permeate flux in the case of HA simulated water treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Patil, Ravikumar V.; Praveen, D.; Damle, R.
2018-05-01
Development of lithium ion batteries employing solid polymer electrolytes as electrolyte material has led to efficient energy storage and usage in many portable devices. However, due to a few drawbacks like lower ionic conductivity of solid polymer electrolytes (SPEs), studies on SPEs for improvement in conductivity still have a good scope. In the present paper, we report the conductivity studies of a new SPE with low molecular weight poly ethylene glycol (PEG) as host polymer in which a salt with larger anion Lithium trifluro methane sulphonate (LTMS). XRD studies have revealed that the salt completely dissociates in the polymer giving a good stable electrolyte at lower salt concentration. Conductivity of the SPEs has been studied as a function of temperature and we reiterate that the conductivity is a thermally activated process and follows Arrhenius type behavior.
Bi-Sr-Ca-Cu-O and Pb-Bi-Sr-Ca-Cu-O superconductor films via an electrodeposition process
NASA Astrophysics Data System (ADS)
Maxfield, M.; Eckhardt, H.; Iqbal, Z.; Reidinger, F.; Baughman, R. H.
1989-05-01
A novel electrochemical process has been developed for the formation of superconducting films. Using this process, superconducting films of Bi2Sr2Ca1Cu2O8 and (Pb,Bi)2Sr2Ca1Cu2O8 have been formed. The process consists of simultaneously depositing the metallic constituents of the superconductor from a single electrolyte, and thermally oxidizing the resulting precursors film to form the superconducting phase. Application of -4 to -5 V vs Ag/Ag(+) to a conductive cathode substrate which is immersed in an electrolyte containing salts of all of the metals reduces the metal cations, causing then to deposit on the cathode as a metallic film precursor. Precursor films having desired stoichiometries were obtained by regulating the electrolyte bath composition.
USDA-ARS?s Scientific Manuscript database
This month’s Processing column will continue the theme of “How Is It Processed?” The column will focus on tofu, which is sometimes called “the cheese of Asia.” It is a nutritious, protein-rich bean curd made by coagulating soy milk. There are many different types of tofu, and they are processed in a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wetering, F. M. J. H. van de; Nijdam, S.; Beckers, J.
2016-07-25
In this letter, we present scanning electron microscopy (SEM) results that confirm in a direct way our earlier explanation of an abrupt coagulation event as the cause for the void hiccup. In a recent paper, we reported on the fast and interrupted expansion of voids in a reactive dusty argon–acetylene plasma. The voids appeared one after the other, each showing a peculiar, though reproducible, behavior of successive periods of fast expansion, abrupt contraction, and continued expansion. The abrupt contraction was termed “hiccup” and was related to collective coagulation of a new generation of nanoparticles growing in the void using relativelymore » indirect methods: electron density measurements and optical emission spectroscopy. In this letter, we present conclusive evidence using SEM of particles collected at different moments in time spanning several growth cycles, which enables us to follow the nanoparticle formation process in great detail.« less
Removal of sodium lauryl sulphate by coagulation/flocculation with Moringa oleifera seed extract.
Beltrán-Heredia, J; Sánchez-Martín, J
2009-05-30
Among other natural flocculant/coagulant agents, Moringa oleifera seed extract ability to remove an anionic surfactant has been evaluated and it has been found to be very interesting. Sodium lauryl sulphate was removed from aqueous solutions up to 80% through coagulation/flocculation process. pH and temperature were found to be not very important factors in removal efficiency. Freundlich (F), Frumkin-Fowler-Guggenheim (FFG) and Gu-Zhu (GZ) models were used to adjust experimental data in a solid-liquid adsorption hypothesis. Last one resulted to be the most accurate one. Several data fit parameters were determined, as Freundlich order, which was found to be 1.66, Flory-Huggins interaction parameter from FFG model, which was found to be 4.87; and limiting Moringa surfactant adsorption capacity from GZ model, which was found to be 2.13 x 10(-3)mol/g.
NASA Astrophysics Data System (ADS)
Tiandho, Y.; Aldila, H.; Mustari; Megiyo; Afriani, F.
2018-05-01
Bangka Belitung Islands is the largest tin producer in Indonesia. The high activity of tin mining caused the environmental damage which had an impact on the emergence of clean water crisis in some areas in this province. In this paper, a simple water quality improvement method based on wasted cockle shell was developed. Based on x-ray diffraction analysis it is known that calcination of cockle shell powder at 700°C will decompose the powder into calcium oxide compound. The addition of calcined cockle shell powder into acidic water from Merawang Sub-district will increase the pH of water through the process of forming hydroxide groups in the water. The calcined cockle shell powder can also coagulate pollutants in some polluted water from Koba Sub-district. The coagulation results were analyzed using SEM/EDS.
Examination of coagulant additives on qualitative composition of selected thermal waters
NASA Astrophysics Data System (ADS)
Łukasiewicz, Ewelina; Rząsa, Mariusz
2017-10-01
On the territory of Poland occur rich deposits of thermal waters. Although the utilisation of these waters is continuously extending, Poland is not exploiting their full geothermal potential due to high investment costs. Thermal waters industry in Poland to date indicates operations within mainly balneology as well as recreation objectives. Higher temperature values of these waters foster a washout in the surrounding rocks resulting in a high concentration of diluted substances which must be often removed. The following study investigates thermal waters from three intakes for which coagulation processes were conducted. Research clearly shows that coagulant additives not impact on the qualitative composition of thermal water, what is very important according to medicinal properties of water. The study results may be further applied as a valuable piece of information for further exploitation in balneology or within the heating sector and other installations.
Curcumin, hemostasis, thrombosis, and coagulation.
Keihanian, Faeze; Saeidinia, Amin; Bagheri, Ramin Khameneh; Johnston, Thomas P; Sahebkar, Amirhossein
2018-06-01
Atherothrombotic cardiovascular disease is a major cause of mortality throughout the world. Platelet activation and aggregation play a central role in hemostasis and thrombosis. Herbal medicines have been traditionally used in the management of cardiovascular disease and can help in modifying its progression, particularly in hemostasis and the coagulation process, as well as altering platelet function tests and some coagulation parameters. Curcumin is a polyphenol derived from the Curcuma longa plant and has been used extensively in complementary and alternative medicine, as it is nontoxic and safe with various therapeutic properties. Modern scientific research has demonstrated its anti-inflammatory, antioxidant, anti-carcinogenic, antithrombotic, and cardiovascular protective effects. The present study reviewed previous studies in the literature, which support the positive activity of curcumin in hemostasis, anticoagulation, and fibrinolysis. We also presented molecular mechanisms associated with the antiplatelet and anticoagulant activities of curcumin and potential implications for the treatment of cardiovascular disease. © 2017 Wiley Periodicals, Inc.
Mesoscopic Modeling of Blood Clotting: Coagulation Cascade and Platelets Adhesion
NASA Astrophysics Data System (ADS)
Yazdani, Alireza; Li, Zhen; Karniadakis, George
2015-11-01
The process of clot formation and growth at a site on a blood vessel wall involve a number of multi-scale simultaneous processes including: multiple chemical reactions in the coagulation cascade, species transport and flow. To model these processes we have incorporated advection-diffusion-reaction (ADR) of multiple species into an extended version of Dissipative Particle Dynamics (DPD) method which is considered as a coarse-grained Molecular Dynamics method. At the continuum level this is equivalent to the Navier-Stokes equation plus one advection-diffusion equation for each specie. The chemistry of clot formation is now understood to be determined by mechanisms involving reactions among many species in dilute solution, where reaction rate constants and species diffusion coefficients in plasma are known. The role of blood particulates, i.e. red cells and platelets, in the clotting process is studied by including them separately and together in the simulations. An agonist-induced platelet activation mechanism is presented, while platelets adhesive dynamics based on a stochastic bond formation/dissociation process is included in the model.
Assessing blood coagulation status with laser speckle rheology
Tripathi, Markandey M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.
2014-01-01
We have developed and investigated a novel optical approach, Laser Speckle Rheology (LSR), to evaluate a patient’s coagulation status by measuring the viscoelastic properties of blood during coagulation. In LSR, a blood sample is illuminated with laser light and temporal speckle intensity fluctuations are measured using a high-speed CMOS camera. During blood coagulation, changes in the viscoelastic properties of the clot restrict Brownian displacements of light scattering centers within the sample, altering the rate of speckle intensity fluctuations. As a result, blood coagulation status can be measured by relating the time scale of speckle intensity fluctuations with clinically relevant coagulation metrics including clotting time and fibrinogen content. Our results report a close correlation between coagulation metrics measured using LSR and conventional coagulation results of activated partial thromboplastin time, prothrombin time and functional fibrinogen levels, creating the unique opportunity to evaluate a patient’s coagulation status in real-time at the point of care. PMID:24688816
Applying the cell-based coagulation model in the management of critical bleeding.
Ho, K M; Pavey, W
2017-03-01
The cell-based coagulation model was proposed 15 years ago, yet has not been applied commonly in the management of critical bleeding. Nevertheless, this alternative model may better explain the physiological basis of current coagulation management during critical bleeding. In this article we describe the limitations of the traditional coagulation protein cascade and standard coagulation tests, and explain the potential advantages of applying the cell-based model in current coagulation management strategies. The cell-based coagulation model builds on the traditional coagulation model and explains many recent clinical observations and research findings related to critical bleeding unexplained by the traditional model, including the encouraging results of using empirical 1:1:1 fresh frozen plasma:platelets:red blood cells transfusion strategy, and the use of viscoelastic and platelet function tests in patients with critical bleeding. From a practical perspective, applying the cell-based coagulation model also explains why new direct oral anticoagulants are effective systemic anticoagulants even without affecting activated partial thromboplastin time or the International Normalized Ratio in a dose-related fashion. The cell-based coagulation model represents the most cohesive scientific framework on which we can understand and manage coagulation during critical bleeding.
Dalvand, Arash; Gholibegloo, Elham; Ganjali, Mohammad Reza; Golchinpoor, Najmeh; Khazaei, Mohammad; Kamani, Hossein; Hosseini, Sara Sadat; Mahvi, Amir Hossein
2016-08-01
In this study, the efficiency of Moringa stenopetala seed extract was compared with alum and M. stenopetala-alum hybrid coagulant to remove Direct Red 23 azo dye from textile wastewater. The effects of parameters such as pH, coagulant dose, type of salt used for the extraction of coagulant and initial dye concentration on dye removal efficiency were investigated. Moreover, the existing functional groups on the structure of M. stenopetala coagulant (MSC) were determined by Fourier transform infrared spectroscopy, and the morphology of sludge produced by MSC, alum, and hybrid coagulant was characterized by scanning electron microscopy. Ninhydrin test was also used to determine the quantity of primary amines in the MSC and Moringa oleifera coagulant (MOC). According to the results, with increasing the coagulant dose and decreasing the initial dye concentration, dye removal efficiency has increased. The maximum dye removal of 98.5, 98.2, and 98.3 % were obtained by using 240, 120, and 80 mg/L MSC, alum and hybrid coagulant at pH 7, respectively. The results also showed MSC was much more effective than MOC for dye removal. The volume of sludge produced by MSC was one fourth and half of those produced by alum and hybrid coagulant, respectively. Based on the results, hybrid coagulant was the most efficient coagulant for direct dye removal from colored wastewater.
NASA Astrophysics Data System (ADS)
Subramania, A.; Kalyana Sundaram, N. T.; Sukumar, N.
A micro-porous polymer electrolyte based on PVA was obtained from PVA-PVC based polymer blend film by a novel preferential polymer dissolution technique. The ionic conductivity of micro-porous polymer electrolyte increases with increase in the removal of PVC content. Finally, the effect of variation of lithium salt concentration is studied for micro-porous polymer electrolyte of high ionic conductivity composition. The ionic conductivity of the micro-porous polymer electrolyte is measured in the temperature range of 301-351 K. It is observed that a 2 M LiClO 4 solution of micro-porous polymer electrolyte has high ionic conductivity of 1.5055 × 10 -3 S cm -1 at ambient temperature. Complexation and surface morphology of the micro-porous polymer electrolytes are studied by X-ray diffraction and SEM analysis. TG/DTA analysis informs that the micro-porous polymer electrolyte is thermally stable upto 277.9 °C. Chronoamperommetry and linear sweep voltammetry studies were made to find out lithium transference number and stability of micro-porous polymer electrolyte membrane, respectively. Cyclic voltammetry study was performed for carbon/micro-porous polymer electrolyte/LiMn 2O 4 cell to reveal the compatibility and electrochemical stability between electrode materials.
Removal of cyanobacteria and cyanotoxins through drinking water treatment-full-scale studies?
This presentation covers the control of intact cyanobacterial cells through particulate removal processes such as coagulation, sedimentation and filtration. The control of cyanobacterial toxins through oxidation and adsorption processes including, but not limited to, chlorine, oz...
Facile and scalable fabrication of polymer-ceramic composite electrolyte with high ceramic loadings
NASA Astrophysics Data System (ADS)
Pandian, Amaresh Samuthira; Chen, X. Chelsea; Chen, Jihua; Lokitz, Bradley S.; Ruther, Rose E.; Yang, Guang; Lou, Kun; Nanda, Jagjit; Delnick, Frank M.; Dudney, Nancy J.
2018-06-01
Solid state electrolytes are a promising alternative to flammable liquid electrolytes for high-energy lithium battery applications. In this work polymer-ceramic composite electrolyte membrane with high ceramic loading (greater than 60 vol%) is fabricated using a model polymer electrolyte poly(ethylene oxide) + lithium trifluoromethane sulfonate and a lithium-conducting ceramic powder. The effects of processing methods, choice of plasticizer and varying composition on ionic conductivity of the composite electrolyte are thoroughly investigated. The physical, structural and thermal properties of the composites are exhaustively characterized. We demonstrate that aqueous spray coating followed by hot pressing is a scalable and inexpensive technique to obtain composite membranes that are amazingly dense and uniform. The ionic conductivity of composites fabricated using this protocol is at least one order of magnitude higher than those made by dry milling and solution casting. The introduction of tetraethylene glycol dimethyl ether further increases the ionic conductivity. The composite electrolyte's interfacial compatibility with metallic lithium and good cyclability is verified by constructing lithium symmetrical cells. A remarkable Li+ transference number of 0.79 is discovered for the composite electrolyte.
Martini, Wenjun Z; Rodriguez, Cassandra M; Deguzman, Rodolfo; Guerra, Jessica B; Martin, Angela K; Pusateri, Anthony E; Cap, Andrew P; Dubick, Michael A
2016-05-01
Ibuprofen is commonly used by warfighters in the deployed environment. This study investigated its dose effects on in vitro coagulation in human and pig blood. Blood samples were collected from 6 normal volunteers and 6 healthy pigs and processed to make platelet-adjusted samples (100 × 10(3)/μL, common transfusion trigger in trauma). Ibuprofen was added to the samples at concentrations of 0 μg/mL (control), the concentration from the highest recommended oral dose (163 μg/mL, 1×), and 2×, 4×, 8×, 10×, 12×, 16×, and 20×. Platelet aggregation by Chrono-Log aggregometer and coagulation by rotational thrombelastogram (Rotem) were assessed at 15 minutes after the addition of ibuprofen. A robust inhibition of ibuprofen on arachidonic acid-induced platelet aggregation was observed at all doses tested in human or pig blood. Collagen-stimulated platelet aggregation was inhibited starting at 1× in human blood and 4× in pig blood. Rotem measurements were similarly compromised in pig and human blood starting at 16×, except clot formation time was prolonged at 1× in human blood (all p < 0.05). Ibuprofen inhibited platelet aggregation at recommended doses, and compromised coagulation at higher doses. Human blood was more sensitive to ibuprofen inhibition. Further effort is needed to investigate ibuprofen dose responses on coagulation in vivo. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
NASA Astrophysics Data System (ADS)
Faridah; Fachraniah; Arifien; Sari, C. M.
2018-03-01
Papain enzyme and carboxyl methyl cellulosa was used in tofu production as coagulant and thickener. Papain enzyme is a protease enzyme that can break proteins. Papain enzymeuseful as coagulant to replace acid and base coagulant. The goal of this study is to observe papain enzyme as coagulant and carboxyl methyl cellulose as thickener to increase characteristic of tofu. Tofu is from soy milk has been pasteurized at 70 °C with the addition of papain enzyme and carboxyl methly cellulose. The concenration of papain enzyme is varied such as 200, 400, 800, and 1000 ppm. After Temperature reachs at 90 °C, carboxyl methyl cellulosa is added in soy milk to produce tofu. This study focuses on introducing papain enzyme as coagulant as well as investigating its potential in improving tofu making process productivity. Further the present work attempts to determine the synergistic effect of combining CMC/enzyme in tofu characteristic. This research was conducted with soy milk pasteurized at 70 °C with increasing papain enzyme. Protein from tofu was determined by using Spectrophotometer UV-VIS Shimadzu UV-1800 type. The highest protein concentration of the papain enzyme was found in 1000 ppm with CMC concentration of 0.6% w/v and based on organoleptic tests that the adding CMC and enzyme papain does not effect the taste, smell, texture and color of tofu. The taste of tofu produced is similar to the taste of tofu in the market.
Meriç, Süreyya; De Nicola, Elena; Iaccarino, Mario; Gallo, Marialuisa; Di Gennaro, Annamaria; Morrone, Gaetano; Warnau, Michel; Belgiorno, Vincenzo; Pagano, Giovanni
2005-10-01
This study was designed to investigate the composition and the toxicity of leather tanning wastewater and conditioned sludge collected at the leather tanning wastewater treatment plant (CODISO) located in Solofra, Avellino (Southern Italy). Samples were analyzed for their conventional parameters (COD, TSS, chromium and ammonia) and for metal content. Effluent samples included raw wastewater, and samples collected following coagulation/flocculation process and biological treatment. A set of toxicity endpoints were tested using sea urchin and marine microalgal bioassays by evaluating acute embryotoxicity, developmental defects, changes in sperm fertilization success and transmissible damage from sperm to the offspring, and changes in algal growth rate. Dose-related toxicity to sea urchin embryogenesis and sperm fertilization success was exerted by effluent or sludge samples according to the following rank: conditioned sludge > coagulated effluent > or = raw influent > effluent from biological treatment. Offspring quality was not affected by sperm exposure to any wastewater or to sludge samples. Algal growth was inhibited by raw or coagulated effluent to a similar extent and, again, the effluent from the biological treatment resulted in a decreased toxicity. The results suggest that coagulated effluent and conditioned sludge result in higher toxicity than raw influent in sea urchin embryos and sperm, whereas the biological wastewater treatment of coagulated effluent, in both sea urchins and algae, cause a substantial improvement of wastewater quality. Hence a final biological wastewater treatment should be operated to minimize any environmental damage from tannery wastewater.
Treatment of Wastewater From Car Washes Using Natural Coagulation and Filtration System
NASA Astrophysics Data System (ADS)
Al-Gheethi, A. A.; Mohamed, R. M. S. R.; Rahman, M. A. A.; Johari, M. R.; Kassim, A. H. M.
2016-07-01
Wastewater generated from carwash is one of the main wastewater resources, which contribute effectively in the increasing of environmental contamination due to the chemical characteristics of the car wastes. The present work aimed to develop an integrated treatment system for carwash wastewater based on coagulation and flocculation using Moringa oleifera and Ferrous Sulphate (FeSO4.7H2O) as well as natural filtration system. The carwash wastewater samples were collected from carwash station located at Parit Raja, Johor, Malaysia. The treatment system of car wash wastewater was designed in the lab scale in four stages included, aeration, coagulation and flocculation, sedimentation and filtration. The coagulation and flocculation unit was carried out using different dosage (35, 70, 105 and 140 mg L-1) of M. oleifera and FeSO4.7H2O, respectively. The efficiency of the integrated treatment system to treat carwash wastewater and to meet Environmental Quality Act (EQA 1974) was evaluated based on the analysis of pH, dissolved oxygen (DO), chemical oxygen demand (COD) and turbidity (NTU). The integrated treatment system was efficient for treatment of raw carwash wastewater. The treated carwash wastewaters meet EQA 1974 regulation 2009 (Standards A) in the term of pH and DO while, turbidity and COD reduced in the wastewater to meet Standards B. The integrated treatment system designed here with natural coagulant (M. oleifera) and filtration unit were effective for primary treatment of carwash wastewater before the final disposal or to be reused again for carwash process.
Factor XI and XII as antithrombotic targets.
Müller, Felicitas; Gailani, David; Renné, Thomas
2011-09-01
Arterial and venous thrombosis are major causes of morbidity and mortality, and the incidence of thromboembolic diseases increases as a population ages. Thrombi are formed by activated platelets and fibrin. The latter is a product of the plasma coagulation system. Currently available anticoagulants such as heparins, vitamin K antagonists and inhibitors of thrombin or factor Xa target enzymes of the coagulation cascade that are critical for fibrin formation. However, fibrin is also necessary for terminating blood loss at sites of vascular injury. As a result, anticoagulants currently in clinical use increase the risk of bleeding, partially offsetting the benefits of reduced thrombosis. This review focuses on new targets for anticoagulation that are associated with minimal or no therapy-associated increased bleeding. Data from experimental models using mice and clinical studies of patients with hereditary deficiencies of coagulation factors XI or XII have shown that both of these clotting factors are important for thrombosis, while having minor or no apparent roles in processes that terminate blood loss (hemostasis). Hereditary deficiency of factor XII (Hageman factor) or factor XI, plasma proteases that initiate the intrinsic pathway of coagulation, impairs thrombus formation and provides protection from vascular occlusive events, while having a minimal impact on hemostasis. As the factor XII-factor XI pathway contributes to thrombus formation to a greater extent than to normal hemostasis, pharmacological inhibition of these coagulation factors may offer the exciting possibility of anticoagulation therapies with minimal or no bleeding risk.
NASA Astrophysics Data System (ADS)
Brunk, Brett Kenneth
1997-11-01
Pollutant and particle transport in estuaries is affected by a multitude of physical, chemical and biological processes. In this research the importance of equilibrium sorption and turbulent coagulation were studied. Sorption in estuaries was modeled using phenanthrene, bacterial extracellular polymer and kaolinite clay as surrogates for a hydrophobic organic pollutant, dissolved organic matter and inorganic suspended sediment, respectively. Experiments over a range of estuarine salinities showed that ionic strength had the largest effect on the extent of sorption, while the effect of extracellular polymer coatings on the mineral surfaces was insignificant. Further calculations using typical estuarine suspended sediment concentrations indicated that equilibrium sorption could not fully account for the solid/solution phase distribution of hydrophobic organic compounds in the estuarine water column. For particles that are small compared to the length scales of turbulence, the rate of coagulation is related to the dynamics of the smallest turbulent eddies since they have the highest shear rate. Experimental and theoretical effort focused on determining the coagulation rate of spherical particles in isotropic turbulence. A pair diffusion approximation valid for rapidly fluctuating flows was used to calculate the rate of coagulation in a randomly varying isotropic linear flow field. Dynamic simulations of particle coagulation in Gaussian turbulence were computed over a range of representative values of particle-particle interactions (i.e, hydrodynamic interactions and van der Waals attraction) and total strain (i.e., the product of the strain rate and its time scale). The computed coagulation rates for isotropic turbulence differed from analytical approximations valid at large and small total strain. As expected, particle interactions were found to be significant. Experimental measurements of coagulation in grid-generated turbulence were obtained by measuring the loss of singlet particles from an initially monodisperse suspension as a function of turbulence intensity. Model predictions based on the particle Hamaker constant and spatial distribution of turbulence in the reactor agreed well with the experiments without the use of any fitting parameters. The close agreement of simulations and observations indicate the numerical model has successfully captured the relevant physics that governs the aggregation of colloidal particles in turbulent flows. This work is the first successful description of turbulent coagulation. Given the ubiquity of turbulent suspensions in engineered and natural systems, the ability to quantitatively describe particle behavior under these conditions is expected to have considerable utility.
Michael, I; Panagi, A; Ioannou, L A; Frontistis, Z; Fatta-Kassinos, D
2014-09-01
This study investigated the application of a solar-driven advanced oxidation process (solar Fenton) combined with previous coagulation/flocculation, for the treatment of olive mill wastewater (OMW) at a pilot scale. Pre-treatment by coagulation/flocculation using FeSO4·7H2O (6.67 g L(-1)) as the coagulant, and an anionic polyelectrolyte (FLOCAN 23, 0.287 g L(-1)) as the flocculant, was performed to remove the solid content of the OMW. The solar Fenton experiments were carried out in a compound parabolic collector pilot plant, in the presence of varying doses of H2O2 and Fe(2+). The optimization of the oxidation process, using reagents at low concentrations ([Fe(2+)] = 0.08 g L(-1); [H2O2] = 1 g L(-1)), led to a high COD removal (87%), while the polyphenolic fraction, which is responsible for the biorecalcitrant and/or toxic properties of OMW, was eliminated. A kinetic study using a modified pseudo first-order kinetic model was performed in order to determine the reaction rate constants. This work evidences also the potential use of the solar Fenton process at the inherent pH of the OMW, yielding only a slightly lower COD removal (81%) compared to that obtained under acidic conditions. Moreover, the results demonstrated the capacity of the applied advanced process to reduce the initial OMW toxicity against the examined plant species (Sorghum saccharatum, Lepidium sativum, Sinapis alba), and the water flea Daphnia magna. The OMW treated samples displayed a varying toxicity profile for each type of organism and plant examined in this study, a fact that can potentially be attributed to the varying oxidation products formed during the process applied. Finally, the overall cost of solar Fenton oxidation for the treatment of 50 m(3) of OMW per day was estimated to be 2.11 € m(-3). Copyright © 2014 Elsevier Ltd. All rights reserved.
Advances in the electrodeposition of aluminum from ionic liquid based electrolytes
NASA Astrophysics Data System (ADS)
Leadbetter, Kirt C.
Aluminum plating is of considerable technical and economic interest because it provides an eco-friendly substitute for cadmium coatings used on many military systems. However, cadmium has been determined to be a significant environmental safety and occupational health (ESOH) hazard because of its toxicity and carcinogenic nature. Furthermore, the cost of treating and disposing of generated wastes, which often contain cyanide, is costly and is becoming prohibitive in the face of increasingly stringent regulatory standards. The non-toxic alternative aluminum is equivalent or superior in performance to cadmium. In addition, it could serve to provide an alternative to hexavalent chromium coatings used on military systems for similar reasons to that of cadmium. Aluminum is a beneficial alternative in that it demonstrates self-healing corrosion resistance in the form of a tightly-bound, impervious oxide layer. A successfully plated layer would be serviceable over a wider temperature range, 925 °F for aluminum compared to 450 oF for cadmium. In addition, an aluminum layer can be anodized to make it non-conducting and colorable. In consideration of the plating process, aluminum cannot be deposited from aqueous solutions because of its reduction potential. Therefore, nonaqueous electrolytes are required for deposition. Currently, aluminum can be electrodeposited in nonaqueous processes that use hazardous chemicals such as toluene and pyrophoric aluminum alkyls. Electrodeposition from ionic liquids provides the potential for a safer method that could be easily scaled up for industrial application. The plating process could be performed at a lower temperature and higher current density than other commercially available aluminum electrodeposition processes; thus a reduced process cost could be possible. The current ionic liquid based electrolytes are more expensive; however production on a larger scale and a long electrolyte lifetime are associated with a reduction in price. Advancements of this nonaqueous aluminum plating process have the potential to lead to a novel and competitive commercial aluminum deposition process. In this investigation aluminum electrodeposition from ionic liquid based electrolytes onto steel, copper and magnesium substrates without conversion coatings or strike layers was evaluated in six different ionic liquid based electrolytes in two technical setups. Three of which are commercially available aluminum plating electrolytes, three of which, discussed in literature were created on site by research personnel in the laboratory. The three commercially available electrolytes were: 1-Butyl-3-methylimidazolium chloride ([BMIm]Cl) * 1.5 AlCl3 with proprietary additives from IoLiTec, 1-Ethyl-3-methylimidazolium chloride ([EMIm]Cl) * 1.5 AlCl3 with proprietary additives from IoLiTec, and BasionicsTM AL-02, an aluminum plating electrolyte containing [EMIm]Cl * 1.5 AlCl3 with additives from BASF. The three electrolytes created on site were based on the 1-ethyl-3-methylimidazolium chloride ionic liquid with added 1.5 AlCl3 and one with added sodium dodecyl sulfate. Small scale plating tests in a 25-mL plating cell were conducted to provide a comparative analysis of the six different electrolytes considered. From these investigations, two were chosen to be evaluated in a larger 1-liter plating cell; designed and constructed to provide a more realistic evaluation of plating parameters with selected electrolytes to better portray industrial electroplating conditions. The effect of current density (10-40 mA/cm 2), temperature (30-90° Celsius) and plating bath agitation on current efficiency, corrosion resistance by the ASTM B117 method, adhesion, microstructure, and chemical composition (evaluated with energy-dispersive x-ray spectroscopy) of the plated Al-layer was explored in both the 25-mL and 1-L plating cell investigations. In addition development of pre- and post-treatment processes for the metal substrates was attempted. While previous investigations focused on one or two of these topics, this research seeks to investigate all discussed phenomena and characteristics. Additionally, there is little research that reports on the adhesion performance of aluminum coatings from ionic liquids. Also, corrosion investigations are limited to all but a few publications. So too, the deposition of aluminum in a larger, more realistic plating cell has never been thoroughly investigated. This is key if a practical application of the technology is ever to be realized. In sum, correlations were drawn between electrolyte, current density, temperature and bath agitation with quality and characteristic of electrodeposited aluminum layers. The overriding goal to create an acceptably competitive aluminum coating process to replace cadmium and compete with other commercial aluminum deposition processes was not successful. Competitiveness was evaluated as per the discussed characteristics and so also, by a comparison to physical samples created in a more realistic plating cell to AlumiPlate aluminum coatings.
Zhang, Shiguo; Ikoma, Ai; Li, Zhe; Ueno, Kazuhide; Ma, Xiaofeng; Dokko, Kaoru; Watanabe, Masayoshi
2016-10-04
Lithium-sulfur (Li-S) batteries are a promising energy-storage technology owing to their high theoretical capacity and energy density. However, their practical application remains a challenge because of the serve shuttle effect caused by the dissolution of polysulfides in common organic electrolytes. Polysulfide-insoluble electrolytes, such as solvate ionic liquids (ILs), have recently emerged as alternative candidates and shown great potential in suppressing the shuttle effect and improving the cycle stability of Li-S batteries. Redox electrochemical reactions in polysulfide-insoluble electrolytes occur via a solid-state process at the interphase between the electrolyte and the composite cathode; therefore, creating an appropriate interface between sulfur and a carbon support is of great importance. Nevertheless, the porous carbon supports established for conventional organic electrolytes may not be suitable for polysulfide-insoluble electrolytes. In this work, we investigated the effect of the porous structure of carbon materials on the Li-S battery performance in polysulfide-insoluble electrolytes using solvate ILs as a model electrolyte. We determined that the pore volume (rather than the surface area) exerts a major influence on the discharge capacity of S composite cathodes. In particular, inverse opal carbons with three-dimensionally ordered interconnected macropores and a large pore volume deliver the highest discharge capacity. The battery performance in both polysulfide-soluble electrolytes and solvate ILs was used to study the effect of electrolytes. We propose a plausible mechanism to explain the different porous structure requirements in polysulfide-soluble and polysulfide-insoluble electrolytes.
Stabilizing electrochemical interfaces in viscoelastic liquid electrolytes
2018-01-01
Electrodeposition is a widely practiced method for creating metal, colloidal, and polymer coatings on conductive substrates. In the Newtonian liquid electrolytes typically used, the process is fundamentally unstable. The underlying instabilities have been linked to failure of microcircuits, dendrite formation on battery electrodes, and overlimiting conductance in ion-selective membranes. We report that viscoelastic electrolytes composed of semidilute solutions of very high–molecular weight neutral polymers suppress these instabilities by multiple mechanisms. The voltage window ΔV in which a liquid electrolyte can operate free of electroconvective instabilities is shown to be markedly extended in viscoelastic electrolytes and is a power-law function, ΔV : η1/4, of electrolyte viscosity, η. This power-law relation is replicated in the resistance to ion transport at liquid/solid interfaces. We discuss consequences of our observations and show that viscoelastic electrolytes enable stable electrodeposition of many metals, with the most profound effects observed for reactive metals, such as sodium and lithium. This finding is of contemporary interest for high-energy electrochemical energy storage. PMID:29582017
Electrolytic decontamination of conductive materials
NASA Astrophysics Data System (ADS)
Campbell, George M.; Nelson, Timothy O.; Parker, John L.; Getty, Richard H.; Hergert, Tom R.; Lindahl, Kirk A.; Peppers, Larry G.
1994-10-01
Using the electrolytic method, we have demonstrated removal of Pu and Am from contaminated conductive material. At EG and G /Rocky Flats, we electrolytically decontaminated stainless steel. Results from this work show removal of fixed contamination, including the following geometries: planar, large radius, bolt holes, glove ports, and protruding studs. More specifically, fixed contamination was reduced from levels ranging from greater than 1 000 000 counts per minute (cpm) down to levels ranging from 1500 to 250 cpm using the electrolytic method. More recently, the electrolytic work has continued at Los Alamos National Laboratory as a joint project with EG and G/Rocky Flats. Impressively, electrolytic decontamination of Pu /Am from U surfaces (10 sq cm per side) shows decreases in swipable contamination from 500 000-1 500 000 disintegrations per minute (dpm) down to 0-2 dpm. Moreover, the solid waste product of the electrolytic method is reduced in volume by more than 50 times compared with the liquid waste produced by the previous U decontamination method -- a hot concentrated acid spray leach process.
Micellar Electrolytes in Organic Electrochemical Transistors
NASA Astrophysics Data System (ADS)
Cicoira, Fabio; Giuseppe, Tarabella; Nanda, Gaurav; Iannotta, Salvatore; Santato, Clara
2012-02-01
Organic electrochemical transistors (OECTs) are promising for applications in sensing and bioelectronics. OECTs consist of a conducting polymer film (transistor channel) in contact with an electrolyte. A gate electrode immersed in the electrolyte controls the doping/dedoping level of the conducting polymer. OECTs can be operated in aqueous electrolytes, making possible the implementation of organic electronic materials at the interface with biology. The inherent signal amplification of OECTs has the potential to yield sensors with low detection limits and high sensitivity. In this talk we will present recent studies on OECTs using ionic surfactants (such as hexadecyl-trimethyl-ammonium bromide) as electrolytes. As the conducting polymer we used PEDOT:PSS, i.e. (Poly,3-4 ethylenedioxythiopene) doped with Poly(styrene sulphonate). Interestingly, ionic surfactant electrolytes result in large transistor current modulation, especially beyond the critical micellar concentration (CMC). Since micelles play a primary role in biological processes and drug-delivery systems, the use for micellar electrolytes opens new exciting opportunities for the use of OECTs in bioelectronics.
An air-stable Na 3SbS 4 superionic conductor prepared by a rapid and economic synthetic procedure
Wang, Hui; Chen, Yan; Hood, Zachary D.; ...
2016-01-01
All-solid-state sodium batteries, using abundant sodium resources and solid electrolyte, hold much promise for safe, low cost, large-scale energy storage. To realize the practical applications of all solid Na-ion batteries at ambient temperature, the solid electrolytes are required to have high ionic conductivity, chemical stability, and ideally, easy preparation. Ceramic electrolytes show higher ionic conductivity than polymers, but they often require extremely stringent synthesis conditions, either high sintering temperature above 1000 C or long-time, low-energy ball milling. Herein, we report a new synthesis route for Na 3SbS 4, a novel Na superionic conductor that needs much lower processing temperature belowmore » 200 C and easy operation. This new solid electrolyte exhibits a remarkable ionic conductivity of 1.05 mS cm -1 at 25 °C and is chemically stable under ambient atmosphere. In conclusion, this synthesis process provides unique insight into the current state-of-the-art solid electrolyte preparation and opens new possibilities for the design of similar materials.« less
Steel refining with an electrochemical cell
Blander, M.; Cook, G.M.
1988-05-17
Apparatus is described for processing a metallic fluid containing iron oxide, container for a molten metal including an electrically conductive refractory disposed for contact with the molten metal which contains iron oxide, an electrolyte in the form of a basic slag on top of the molten metal, an electrode in the container in contact with the slag electrically separated from the refractory, and means for establishing a voltage across the refractory and the electrode to reduce iron oxide to iron at the surface of the refractory in contact with the iron oxide containing fluid. A process is disclosed for refining an iron product containing not more than about 10% by weight oxygen and not more than about 10% by weight sulfur, comprising providing an electrolyte of a slag containing one or more of calcium oxide, magnesium oxide, silica or alumina, providing a cathode of the iron product in contact with the electrolyte, providing an anode in contact with the electrolyte electrically separated from the cathode, and operating an electrochemical cell formed by the anode, the cathode and the electrolyte to separate oxygen or sulfur present in the iron product therefrom. 2 figs.
Steel refining with an electrochemical cell
Blander, M.; Cook, G.M.
1985-05-21
Disclosed is an apparatus for processing a metallic fluid containing iron oxide, container for a molten metal including an electrically conductive refractory disposed for contact with the molten metal which contains iron oxide, an electrolyte in the form of a basic slag on top of the molten metal, an electrode in the container in contact with the slag electrically separated from the refractory, and means for establishing a voltage across the refractory and the electrode to reduce iron oxide to iron at the surface of the refractory in contact with the iron oxide containing fluid. A process is disclosed for refining an iron product containing not more than about 10% by weight sulfur, comprising providing an electrolyte of a slag containing one or more of calcium oxide, magnesium oxide, silica or alumina, providing a cathode of the iron product in contact with the electrolyte, providing an anode in contact with the electrolyte electrically separated from the cathode, and operating an electrochemical cell formed by the anode, the cathode and the electrolyte to separate oxygen or sulfur present in the iron product therefrom.
Steel refining with an electrochemical cell
Blander, Milton; Cook, Glenn M.
1988-01-01
Apparatus for processing a metallic fluid containing iron oxide, container for a molten metal including an electrically conductive refractory disposed for contact with the molten metal which contains iron oxide, an electrolyte in the form of a basic slag on top of the molten metal, an electrode in the container in contact with the slag electrically separated from the refractory, and means for establishing a voltage across the refractory and the electrode to reduce iron oxide to iron at the surface of the refractory in contact with the iron oxide containing fluid. A process is disclosed for refining an iron product containing not more than about 10% by weight oxygen and not more than about 10% by weight sulfur, comprising providing an electrolyte of a slag containing one or more of calcium oxide, magnesium oxide, silica or alumina, providing a cathode of the iron product in contact with the electrolyte, providing an anode in contact with the electrolyte electrically separated from the cathode, and operating an electrochemical cell formed by the anode, the cathode and the electrolyte to separate oxygen or sulfur present in the iron product therefrom.
Refractory lining for electrochemical cell
Blander, Milton; Cook, Glenn M.
1987-01-01
Apparatus for processing a metallic fluid containing iron oxide, container for a molten metal including an electrically conductive refractory disposed for contact with the molten metal which contains iron oxide, an electrolyte in the form of a basic slag on top of the molten metal, an electrode in the container in contcat with the slag electrically separated from the refractory, and means for establishing a voltage across the refractory and the electrode to reduce iron oxide to iron at the surface of the refractory in contact with the iron oxide containing fluid. A process is disclosed for refining an iron product containing not more than about 10% by weight oxygen and not more than about 10% by weight sulfur, comprising providing an electrolyte of a slag containing one or more of calcium oxide, magnesium oxide, silica or alumina, providing a cathode of the iron product in contact with the electrolyte, providing an anode in contact with the electrolyte electrically separated from the cathode, and operating an electrochemical cell formed by the anode, the cathode and the electrolyte to separate oxygen or sulfur present in the iron product therefrom.
Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds.
Okuda, T; Baes, A U; Nishijima, W; Okada, M
2001-03-01
This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC tap water formed insoluble matters. This formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each molecule of the active coagulation component in MOC-SC-PC and form a net-like structure. The coagulation mechanism of MOC-SC-PC seemed to be an enmeshment of Kaolin by the insoluble matters with the net-like structure. In case of Ca2+ ion (bivalent cations), at least 0.2 mM was necessary for coagulation at 0.3 mgC l-1 dose of MOC-SC-PC. Other coagulation mechanisms like compression of double layer, interparticle bridging or charge neutralization were not responsible for the coagulation by MOC-SC-PC.
ELECTROCHEMICAL DECONTAMINATION AND RECOVERY OF URANIUM VALUES
McLaren, J.A.; Goode, J.H.
1958-05-13
An electrochemical process is described for separating uranium from fission products. The method comprises subjecting the mass of uranium to anodic dissolution in an electrolytic cell containing aqueous alkali bicarbonate solution as its electrolyte, thereby promoting a settling from the solution of a solid sludge from about the electrodes and separating the resulting electrolyte solution containing the anodically dissolved uranium from the sludge which contains the rare earth fission products.
Solvothermal synthesis of gallium-indium-zinc-oxide nanoparticles for electrolyte-gated transistors.
Santos, Lídia; Nunes, Daniela; Calmeiro, Tomás; Branquinho, Rita; Salgueiro, Daniela; Barquinha, Pedro; Pereira, Luís; Martins, Rodrigo; Fortunato, Elvira
2015-01-14
Solution-processed field-effect transistors are strategic building blocks when considering low-cost sustainable flexible electronics. Nevertheless, some challenges (e.g., processing temperature, reliability, reproducibility in large areas, and cost effectiveness) are requirements that must be surpassed in order to achieve high-performance transistors. The present work reports electrolyte-gated transistors using as channel layer gallium-indium-zinc-oxide nanoparticles produced by solvothermal synthesis combined with a solid-state electrolyte based on aqueous dispersions of vinyl acetate stabilized with cellulose derivatives, acrylic acid ester in styrene and lithium perchlorate. The devices fabricated using this approach display a ION/IOFF up to 1 × 10(6), threshold voltage (VTh) of 0.3-1.9 V, and mobility up to 1 cm(2)/(V s), as a function of gallium-indium-zinc-oxide ink formulation and two different annealing temperatures. These results validates the usage of electrolyte-gated transistors as a viable and promising alternative for nanoparticle based semiconductor devices as the electrolyte improves the interface and promotes a more efficient step coverage of the channel layer, reducing the operating voltage when compared with conventional dielectrics gating. Moreover, it is shown that by controlling the applied gate potential, the operation mechanism of the electrolyte-gated transistors can be modified from electric double layer to electrochemical doping.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhaoying; Zhang, Yanyan; Liu, Bingwen
The in situ molecular characterization of reaction intermediates and products at electrode-electrolyte interfaces is central to mechanistic studies of complex electrochemical processes, yet a great challenge. The coupling of electrochemistry (EC) and mass spectrometry (MS) has seen rapid development and found broad applicability in tackling challenges in analytical and bioanalytical chemistry. However, few truly in situ and real-time EC-MS studies have been reported at electrode-electrolyte interfaces. An innovative EC-MS coupling method named in situ liquid secondary ion mass spectrometry (SIMS) was recently developed by combining SIMS with a vacuum compatible microfluidic electrochemical device. Using this novel capability we report themore » first in situ elucidation of the electro-oxidation mechanism of a biologically significant organic compound, ascorbic acid (AA), at the electrode-electrolyte interface. The short-lived radical intermediate was successfully captured, which had not been detected directly before. Moreover, we demonstrated the power of this new technique in real-time monitoring of the formation and dynamic evolution of electrical double layers at the electrode-electrolyte interface. This work suggests further promising applications of in situ liquid SIMS in studying more complex chemical and biological events at the electrode-electrolyte interface.« less
Eberhart, James G.; Battles, James E.
1980-01-01
Electrochemical cell components such as interelectrode separators, retaining screens and current collectors are contacted with lithium tetrachloroaluminate prior to contact with molten electrolytic salt to improve electrolyte wetting. The LiAlCl.sub.4 can be applied in powdered, molten or solution form but, since this material has a lower melting point than the electrolytic salt used in high-temperature cells, the powdered LiAlCl.sub.4 forms a molten flux prior to contact by the molten electrolyte when both materials are initially provided in solid form. Components of materials such as boron nitride and other materials which are difficult to wet with molten salts are advantageously treated by this process.
Operating a redox flow battery with a negative electrolyte imbalance
Pham, Quoc; Chang, On; Durairaj, Sumitha
2015-03-31
Loss of flow battery electrode catalyst layers during self-discharge or charge reversal may be prevented by establishing and maintaining a negative electrolyte imbalance during at least parts of a flow battery's operation. Negative imbalance may be established and/or maintained actively, passively or both. Actively establishing a negative imbalance may involve detecting an imbalance that is less negative than a desired threshold, and processing one or both electrolytes until the imbalance reaches a desired negative level. Negative imbalance may be effectively established and maintained passively within a cell by constructing a cell with a negative electrode chamber that is larger than the cell's positive electrode chamber, thereby providing a larger quantity of negative electrolyte for reaction with positive electrolyte.
Yap, R K L; Whittaker, M; Diao, M; Stuetz, R M; Jefferson, B; Bulmus, V; Peirson, W L; Nguyen, A V; Henderson, R K
2014-09-15
Dissolved air flotation (DAF), an effective treatment method for clarifying algae/cyanobacteria-laden water, is highly dependent on coagulation-flocculation. Treatment of algae can be problematic due to unpredictable coagulant demand during blooms. To eliminate the need for coagulation-flocculation, the use of commercial polymers or surfactants to alter bubble charge in DAF has shown potential, termed the PosiDAF process. When using surfactants, poor removal was obtained but good bubble adherence was observed. Conversely, when using polymers, effective cell removal was obtained, attributed to polymer bridging, but polymers did not adhere well to the bubble surface, resulting in a cationic clarified effluent that was indicative of high polymer concentrations. In order to combine the attributes of both polymers (bridging ability) and surfactants (hydrophobicity), in this study, a commercially-available cationic polymer, poly(dimethylaminoethyl methacrylate) (polyDMAEMA), was functionalised with hydrophobic pendant groups of various carbon chain lengths to improve adherence of polymer to a bubble surface. Its performance in PosiDAF was contrasted against commercially-available poly(diallyl dimethyl ammonium chloride) (polyDADMAC). All synthesised polymers used for bubble surface modification were found to produce positively charged bubbles. When applying these cationic micro-bubbles in PosiDAF, in the absence of coagulation-flocculation, cell removals in excess of 90% were obtained, reaching a maximum of 99% cell removal and thus demonstrating process viability. Of the synthesised polymers, the polymer containing the largest hydrophobic functionality resulted in highly anionic treated effluent, suggesting stronger adherence of polymers to bubble surfaces and reduced residual polymer concentrations. Copyright © 2014 Elsevier Ltd. All rights reserved.
Xu, Jie; Zhao, Yanxia; Gao, Baoyu; Han, Songlin; Zhao, Qian; Liu, Xiaoli
2018-04-01
Cyanobacterial bloom causes the release of algal organic matter (AOM), which inevitably affects the treatment processes of natural organic matter (NOM). This study works on treating micro-polluted surface water (SW) by emerging coagulant, namely titanium sulfate (Ti(SO 4 ) 2 ), followed by Low Pressure Ultrafiltration (LPUF) technology. In particular, we explored the respective influence of extracellular organic matter (EOM) and intracellular organic matter (IOM) on synergetic EOM-NOM/IOM-NOM removal, functional mechanisms and subsequent filtration performance. Results show that the IOM inclusion in surface water body facilitated synergic IOM-NOM composite pollutants removal by Ti(SO 4 ) 2 , wherein loosely-aggregated flocs were produced, resulting in floc cake layer with rich porosity and permeability during LPUF. On the contrary, the surface water invaded by EOM pollutants increased Ti(SO 4 ) 2 coagulation burden, with substantially deteriorated both UV 254 -represented and dissolved organic matter (DOC) removal. Corresponded with the weak Ti(SO 4 ) 2 coagulation for EOM-NOM removal was the resultant serious membrane fouling during LPUF procedure, wherein dense cake layer was formed due to the compact structure of flocs. Although the IOM enhanced NOM removal with reduced Ti(SO 4 ) 2 dose and yielded mitigated membrane fouling, larger percentage of irreversible fouling was seen than NOM and EOM-NOM cases, which was most likely due to the substances with small molecular weight, such as microcystin, adhering in membrane pores. This research would provide theoretical basis for dose selection and process design during AOM-NOM water treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.
Cheng, Xiaoxiang; Liang, Heng; Ding, An; Tang, Xiaobin; Liu, Bin; Zhu, Xuewu; Gan, Zhendong; Wu, Daoji; Li, Guibai
2017-04-15
Ferrous iron/peroxymonosulfate (Fe(II)/PMS) oxidation was employed as a pretreatment method for ultrafiltration process to control membrane fouling caused by natural organic matter, including humic acid (HA), sodium alginate (SA), bovine serum albumin (BSA), and their mixture (HA-SA-BSA). To evaluate the mechanism of fouling mitigation, the effects of Fe(II)/PMS pretreatment on the characteristics of feed water were examined. The degradation of atrazine (ATZ) was also investigated and the species of generated radicals were preliminarily determined. Under the test exposure (15 and 50 μM), Fe(II)/PMS pretreatment effectively mitigated membrane fouling caused by HA, SA and HA-SA-BSA mixture, and the performance improved with the increase of Fe(II) or PMS dose; whereas aggravated BSA fouling at lower doses and fouling alleviation was observed only at a higher dose (50/50 μΜ). The fouling mitigation was mainly attributed to the effective reduction of organic loadings by coagulation with in-situ formed Fe(III). Its performance was comparable or even slightly higher than single coagulation with Fe(III), most likely due to the oxidation by Fe(II)/PMS process. Fe(II)/PMS oxidation showed better performance in reducing DOC and UV 254 , fluorescence intensities of fluorescent components and UV-absorbing compounds than single coagulation. In addition, Fe(II)/PMS pretreatment was efficient in ATZ degradation due to the generation of sulfate and hydroxyl radicals, whereas coagulation was ineffective to remove it. Copyright © 2017 Elsevier Ltd. All rights reserved.
Variations in toxicity of semi-coking wastewater treatment processes and their toxicity prediction.
Ma, Xiaoyan; Wang, Xiaochang; Liu, Yongjun; Gao, Jian; Wang, Yongkun
2017-04-01
Chemical analyses and bioassays using Vibrio fischeri and Daphnia magna were conducted to evaluate comprehensively the variation of biotoxicity caused by contaminants in wastewater from a semi-coking wastewater treatment plant (WWTP). Pretreatment units (including an oil-water separator, a phenols extraction tower, an ammonia stripping tower, and a regulation tank) followed by treatment units (including anaerobic-oxic treatment units, coagulation-sedimentation treatment units, and an active carbon adsorption column) were employed in the semi-coking WWTP. Five benzenes, 11 phenols, and five polycyclic aromatic hydrocarbons (PAHs) were investigated as the dominant contaminants in semi-coking wastewater. Because of residual extractant, the phenols extraction process increased acute toxicity to V. fischeri and immobilization and lethal toxicity to D. magna. The acute toxicity of pretreated wastewater to V. fischeri was still higher than that of raw semi-coking wastewater, even though 90.0% of benzenes, 94.8% of phenols, and 81.0% of PAHs were removed. After wastewater pretreatment, phenols and PAHs were mainly removed by anaerobic-oxic and coagulation-sedimentation treatment processes respectively, and a subsequent active carbon adsorption process further reduced the concentrations of all target chemicals to below detection limits. An effective biotoxicity reduction was found during the coagulation-sedimentation and active carbon adsorption treatment processes. The concentration addition model can be applied for toxicity prediction of wastewater from the semi-coking WWTP. The deviation between the measured and predicted toxicity results may result from the effects of compounds not detectable by instrumental analyses, the synergistic effect of detected contaminants, or possible transformation products. Copyright © 2016. Published by Elsevier Inc.
Magnetic Resonance Mediated Radio Frequency Coagulation for Vascular Repair
NASA Astrophysics Data System (ADS)
Zhao, Ming
Purpose. Magnetic Resonance Mediated Radiofrequency Coagulation employs the RF heating effect of MRI scanning to coagulate biomaterials for repair of vascular defects. Coagulation of a protein biomaterial by MR-induced RF heating is a novel means to effect repair of defects such as aneurysms or arteriovenous malformations. Our novel method is to coagulate a thermosetting material (such as egg white, which can be used for investigating heat coagulation behavior and MR relaxation properties) delivered endovascularly by catheter and coagulated by RF-induced heating of an intracatheter resonant wire antenna in the scanner. Methods. Experiments were performed on a Siemens 1.5 T MRI scanner and a Bruker 14T NMR spectrometer. Egg white was brought to equilibrium at seven temperatures (20, 30, 40, 50, 60, 70 and 37 °C) in sequence. Measurement of the water spin-lattice relaxation time Ti, spin-spin relaxation time T2, spin-lattice relaxation time in the rotating frame T1p, or full width at half maximum of the MT spectrum were performed at each temperature. Relaxation parameters of raw egg white and egg white after coagulation at 70 °C were measured in the scanner at 20 °C to determine optimum inversion time, echo time and offset frequency for good image contrast between coagulated and uncoagulated protein. Finally, coagulation of egg white within a glass aneurysm phantom by RF heating in the scanner was performed to demonstrate the MR coagulation methodology and the ability to achieve image contrast between coagulated and uncoagulated biomaterial. Results. Water T2, T1p and MT gave the most definitive indication of the change from uncoagulated at low temperature to fully coagulated at 60 °C, while water T1 showed only the expected gradual increase with temperature, and no response to coagulation. MT weighted imaging is expected to be the optimum method to establish the coagulation condition of the biomaterial.
Coagulation monitoring based on blood elastic measurement using optical coherence tomography
NASA Astrophysics Data System (ADS)
Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping
2017-02-01
Blood coagulation monitoring is important to diagnose hematological diseases and cardiovascular diseases and to predict the risk of bleeding and excessive clotting. In this study, we developed a system to dynamically monitor blood coagulation and quantitatively determine the coagulation function by blood elastic measurement. When blood forms a clot from a liquid, ultrasonic force induces a shear wave, which is detected by optical coherence tomography (OCT). The coagulation of porcine whole blood recalcified by calcium chloride is assessed using the metrics of reaction time, clot formation kinetics and maximum shear modulus. The OCE system can noninvasively monitor the blood coagulation and quantitatively determine the coagulation function.
NASA Astrophysics Data System (ADS)
Rogov, A. B.; Shayapov, V. R.
2017-02-01
In this paper, the influence of cationic electrolytes composition on electrical and optical responses of plasma electrolytic oxidation process of A1050 aluminum alloy under alternating polarization is considered. The electrolytes consist of 0.1 M boric acid with addition of one of the following hydroxides: LiOH, NaOH, KOH, tetraethylammonium hydroxide, Ca(OH)2 up to pH value 9.2. Coatings microstructure, elemental and phase compositions were studied by SEM, EDS and XRD. It was shown that the hysteresis of anodic current-voltage curve (specific feature of "Soft sparking" PEO) was clear observed in the presence of sodium and potassium cations. It was found that composition of microdischarges plasma is also affected by the nature of the cations. It was shown that there are a number of reciprocal processes, which take place under anodic and cathodic polarization.
NASA Astrophysics Data System (ADS)
Tripathi, Markandey M.; Tshikudi, Diane M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.
2016-02-01
Impaired blood coagulation is often associated with increased postoperative mortality and morbidity in cardiovascular patients. The capability for blood coagulation profiling rapidly at the bedside will enable the timely detection of coagulation defects and open the opportunity for tailoring therapy to correct specific coagulation deficits Optical Thromboelastography (OTEG), is an optical approach to quantify blood coagulation status within minutes using a few drops of whole blood. The goal of the current study is to evaluate the diagnostic accuracy of OTEG for rapid coagulation profiling in patients. In OTEG, temporal laser speckle intensity fluctuations from a drop of clotting blood are measured using a CMOS camera. To quantify coagulation status, the speckle intensity autocorrelation function is measured, the mean square displacement of scattering particles is extracted, and viscoelastic modulus (G), during coagulation is measured via the generalized Stokes-Einstein relation. By quantifying time-resolved changes in G, the coagulation parameters, reaction time (R), clot progression time (K), clot progression rate (Angle), and maximum clot strength (MA) are derived. In this study, the above coagulation parameters were measured using OTEG in 269 patients and compared with standard mechanical Thromboelastography (TEG). Our results showed a strong correlation between OTEG and TEG measurements for all parameters: R-time (R=0.80, p<0.001), clotting time (R=0.78, p<0.001), Angle (R=0.58, p<0.001), and MA (R=0.60, p<0.001). These results demonstrate the unique capability of OTEG for rapid quantification of blood coagulation status to potentially improve clinical capability for identifying impaired coagulation in cardiovascular patients at the point of care.
Ohba, Tomonori
2014-02-24
An understanding of the structure and behavior of electrolyte solutions in nanoenvironements is crucial not only for a wide variety of applications, but also for the development of physical, chemical, and biological processes. We demonstrate the structure and stability of electrolyte in carbon nanotubes using hybrid reverse Monte Carlo simulations of X-ray diffraction patterns. Hydrogen bonds between water are adequately formed in carbon nanotubes, although some hydrogen bonds are restricted by the interfaces of carbon nanotubes. The hydrogen bonding network of water in electrolyte in the carbon nanotubes is further weakened. On the other hand, formation of the ion hydration shell is significantly enhanced in the electrolyte in the carbon nanotubes in comparison to ion hydration in bulk electrolyte. The significant hydrogen bond and hydration shell formation are a result of gaining stability in the hydrophobic nanoenvironment. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Keller, Marlou; Appetecchi, Giovanni Battista; Kim, Guk-Tae; Sharova, Varvara; Schneider, Meike; Schuhmacher, Jörg; Roters, Andreas; Passerini, Stefano
2017-06-01
The preparation of hybrid ceramic-polymer electrolytes, consisting of 70 wt% of Li+ cation conducting Li7La3Zr2O12 (LLZO) and 30 wt% of P(EO)15LiTFSI polymer electrolyte, through a solvent-free procedure is reported. The LLZO-P(EO)15LiTFSI hybrid electrolytes exhibit remarkable improvement in terms of flexibility and processability with respect to pure LLZO ceramic electrolytes. The physicochemical and electrochemical investigation shows the effect of LLZO annealing, resulting in ion conduction gain. However, slow charge transfer at the ceramic-polymer interface is also observed especially at higher temperatures. Nevertheless, improved compatibility with lithium metal anodes and good Li stripping/plating behavior are exhibited by the LLZO-P(EO)15LiTFSI hybrid electrolytes with respect to P(EO)15LiTFSI.
Conversion of Carbon Dioxide into Ethanol by Electrochemical Synthesis Method Using Cu-Zn Electrode
NASA Astrophysics Data System (ADS)
Riyanto; Ramadan, S.; Fariduddin, S.; Aminudin, A. R.; Hayatri, A. K.
2018-01-01
Research on conversion of carbon dioxide into ethanol has been done. The conversion process is carried out in a sodium bicarbonate electrolyte solution in an electrochemical synthesis reactor. As cathode was used Cu-Zn, while as anode carbon was utilized. Variations of voltage, concentration of sodium bicarbonate electrolyte solution and time of electrolysis were performed to determine the optimum conditions to convert carbon dioxide into ethanol. Sample of the electrochemical synthesis process was analyzed by gas chromatography. From the result, it is found that the optimum conditions of the electrochemical synthesis process of carbon dioxide conversion into ethanol are voltage, concentration of sodium bicarbonate electrolyte solution and time of electrolysis are 3 volts, 0.4 M and 90 minutes with the ethanol concentration of 10.44%.
Köhler, Stephan J; Lavonen, Elin; Keucken, Alexander; Schmitt-Kopplin, Philippe; Spanjer, Tom; Persson, Kenneth
2016-02-01
Rising organic matter concentrations in surface waters in many Nordic countries require current drinking water treatment processes to be adapted. Accordingly, the use of a novel nanofiltration (NF) membrane was studied during a nine month period in pilot scale at a large drinking water treatment plant in Stockholm, Sweden. A chemically resistant hollow-fibre NF membrane was fed with full scale process water from a rapid sand filter after aluminum sulfate coagulation. The combined coagulation and NF process removed more than 90% of the incoming lake water dissolved organic carbon (DOC) (8.7 mg C L(-1)), and 96% of the absorbance at 254 nm (A254) (0.28 cm(-1) incoming absorbance). Including granulated active carbon GAC) filter, the complete pilot plant treatment process we observed decreases in DOC concentration (8.7-0.5 mg C L(-1)), SUVA (3.1-1.7 mg(-1) L m(-1)), and the average nominal molecular mass (670-440 Da). Meanwhile, water hardness was practically unaffected (<20% reduction). Humic substances (HS) and biopolymers were almost completely eliminated (6510-140 and 260 to 10 μg C L(-1) respectively) and low molecular weight (LMW) neutrals decreased substantially (880-190 μg C L(-1)). Differential excitation emission matrices (EEMs), which illustrate the removal of fluorescing organic matter (FDOM) over a range of excitation and emission wavelengths, demonstrate that coagulation removed 35 ± 2% of protein-like material and 65 ± 2% of longer emission wavelength, humic-like FDOM. The subsequent NF treatment was somewhat less selective but still preferentially targeted humic-like FDOM (83 ± 1%) to a larger extent than protein-like material (66 ± 3%). The high selectivity of organic matter during coagulation compared to NF separation was confirmed from analyses with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS), and liquid chromatography with organic carbon detection (LC-OCD), as coagulation exclusively targeted oxidized organic matter components while NF removed both chemically reduced and oxidized components. DOC removal and change in DOC character in the GAC filters showed marked differences with slower saturation and more pronounced shifts in DOC character using NF as pre-treatment. Fluorescence derived parameters showed a similar decrease over time of GAC performance for the first 150 days but also indicated ongoing change of DOM character in the post NF GAC filtrate over time even after LC-OCD indicated steady state with respect to outgoing carbon. During our trial iron concentrations were low (<30 ppb) and thus A254 could be directly related to the concentration of HS (R(2) = 0.9). The fluorescence derived freshness index (β:α) proved to be an excellent variable for estimating the fraction of HS present in all samples. Given the recommended limit of 4 mg L(-1) for chemical oxygen demand (COD) for Swedish drinking water, coagulation will need to be supplemented with one or more treatment steps irrespective whether climate change will lead to drier or wetter conditions in order to maintain sufficient DOC removal with the current increasing concentrations in raw waters. Copyright © 2015 Elsevier Ltd. All rights reserved.
Analytical solutions for coagulation and condensation kinetics of composite particles
NASA Astrophysics Data System (ADS)
Piskunov, Vladimir N.
2013-04-01
The processes of composite particles formation consisting of a mixture of different materials are essential for many practical problems: for analysis of the consequences of accidental releases in atmosphere; for simulation of precipitation formation in clouds; for description of multi-phase processes in chemical reactors and industrial facilities. Computer codes developed for numerical simulation of these processes require optimization of computational methods and verification of numerical programs. Kinetic equations of composite particle formation are given in this work in a concise form (impurity integrated). Coagulation, condensation and external sources associated with nucleation are taken into account. Analytical solutions were obtained in a number of model cases. The general laws for fraction redistribution of impurities were defined. The results can be applied to develop numerical algorithms considerably reducing the simulation effort, as well as to verify the numerical programs for calculation of the formation kinetics of composite particles in the problems of practical importance.
Gumińska, Jolanta; Kłos, Marcin
2015-01-01
Filtration efficiency in a conventional water treatment system was analyzed in the context of pre-hydrolyzed coagulant overdosing. Two commercial coagulants of different aluminum speciation were tested. A study was carried out at a water treatment plant supplied with raw water of variable quality. The lack of stability of water quality caused many problems with maintaining the optimal coagulant dose. The achieved results show that the type of coagulant had a very strong influence on the effectiveness of filtration resulting from the application of an improper coagulant dose. The overdosing of high basicity coagulant (PAC85) caused a significant increase of fine particles in the outflow from the sedimentation tanks, which could not be retained in the filter bed due to high surface charge and the small size of hydrolysis products. When using a coagulant of lower basicity (PAC70), it was much easier to control the dose of coagulant and to adjust it to the changing water quality.
Chemical coagulation of combined sewer overflow: heavy metal removal and treatment optimization.
El Samrani, A G; Lartiges, B S; Villiéras, F
2008-02-01
The coagulation of combined sewer overflow (CSO) was investigated by jar-testing with two commercial coagulants, a ferric chloride solution (CLARFER) and a polyaluminium chloride (WAC HB). CSO samples were collected as a function of time during various wet-weather events from the inlet of Boudonville retention basin, Nancy, France. Jar-tests showed that an efficient turbidity removal can be achieved with both coagulants, though lower optimum dosages and higher re-stabilization concentrations were obtained with the aluminum-based coagulant. Optimum turbidity removal also yielded effective heavy metal elimination. However, the evolution with coagulant dosage of Cu, Zn, Pb, Cr, soluble and suspended solids contents followed various patterns. The removal behaviors can be explained by a selective aggregation of heavy metal carriers present in CSO and a specific interaction between hydrolyzed coagulant species and soluble metals. Stoichiometric relationships were established between optimal coagulant concentration, range of optimal dosing, and CSO conductivity, thus providing useful guidelines to adjust the coagulant demand during the course of CSO events.
Rapid, cool sintering of wet processed yttria-stabilized zirconia ceramic electrolyte thin films.
Park, Jun-Sik; Kim, Dug-Joong; Chung, Wan-Ho; Lim, Yonghyun; Kim, Hak-Sung; Kim, Young-Beom
2017-09-29
Here we report a photonic annealing process for yttria-stabilized zirconia films, which are one of the most well-known solid-state electrolytes for solid oxide fuel cells (SOFCs). Precursor films were coated using a wet-chemical method with a simple metal-organic precursor solution and directly annealed at standard pressure and temperature by two cycles of xenon flash lamp irradiation. The residual organics were almost completely decomposed in the first pre-annealing step, and the fluorite crystalline phases and good ionic conductivity were developed during the second annealing step. These films showed properties comparable to those of thermally annealed films. This process is much faster than conventional annealing processes (e.g. halogen furnaces); a few seconds compared to tens of hours, respectively. The significance of this work includes the treatment of solid-state electrolyte oxides for SOFCs and the demonstration of the feasibility of other oxide components for solid-state energy devices.
Ultra-thin solid oxide fuel cells: Materials and devices
NASA Astrophysics Data System (ADS)
Kerman, Kian
Solid oxide fuel cells are electrochemical energy conversion devices utilizing solid electrolytes transporting O2- that typically operate in the 800 -- 1000 °C temperature range due to the large activation barrier for ionic transport. Reducing electrolyte thickness or increasing ionic conductivity can enable lower temperature operation for both stationary and portable applications. This thesis is focused on the fabrication of free standing ultrathin (<100 nm) oxide membranes of prototypical O 2- conducting electrolytes, namely Y2O3-doped ZrO2 and Gd2O3-doped CeO2. Fabrication of such membranes requires an understanding of thin plate mechanics coupled with controllable thin film deposition processes. Integration of free standing membranes into proof-of-concept fuel cell devices necessitates ideal electrode assemblies as well as creative processing schemes to experimentally test devices in a high temperature dual environment chamber. We present a simple elastic model to determine stable buckling configurations for free standing oxide membranes. This guides the experimental methodology for Y 2O3-doped ZrO2 film processing, which enables tunable internal stress in the films. Using these criteria, we fabricate robust Y2O3-doped ZrO2 membranes on Si and composite polymeric substrates by semiconductor and micro-machining processes, respectively. Fuel cell devices integrating these membranes with metallic electrodes are demonstrated to operate in the 300 -- 500 °C range, exhibiting record performance at such temperatures. A model combining physical transport of electronic carriers in an insulating film and electrochemical aspects of transport is developed to determine the limits of performance enhancement expected via electrolyte thickness reduction. Free standing oxide heterostructures, i.e. electrolyte membrane and oxide electrodes, are demonstrated. Lastly, using Y2O3-doped ZrO2 and Gd2O 3-doped CeO2, novel electrolyte fabrication schemes are explored to develop oxide alloys and nanoscale compositionally graded membranes that are thermomechanically robust and provide added interfacial functionality. The work in this thesis advances experimental state-of-the-art with respect to solid oxide fuel cell operation temperature, provides fundamental boundaries expected for ultrathin electrolytes, develops the ability to integrate highly dissimilar material (such as oxide-polymer) heterostructures, and introduces nanoscale compositionally graded electrolyte membranes that can lead to monolithic materials having multiple functionalities.
Ma, Ya; Cui, Yan; Zuo, Xiaoxi; Huang, Shanna; Hu, Keshui; Xiao, Xin; Nan, Junmin
2014-10-01
A process for reclaiming the materials in spent alkaline zinc manganese dioxide (Zn-Mn) batteries collected from the manufacturers to prepare valuable electrolytic zinc and LiNi0.5Mn1.5O4 materials is presented. After dismantling battery cans, the iron cans, covers, electric rods, organic separator, label, sealing materials, and electrolyte are separated through the washing, magnetic separation, filtrating, and sieving operations. Then, the powder residues react with H2SO4 (2 mol L(-1)) solution to dissolve zinc under a liquid/solid ratio of 3:1 at room temperature, and subsequently, the electrolytic Zn with purity of ⩾99.8% is recovered in an electrolytic cell with a cathode efficiency of ⩾85% under the conditions of 37-40°C and 300 A m(-2). The most of MnO2 and a small quantity of electrolytic MnO2 are recovered from the filtration residue and the electrodeposit on the anode of electrolytic cell, respectively. The recovered manganese oxides are used to synthesize LiNi0.5Mn1.5O4 material of lithium-ion battery. The as-synthesized LiNi0.5Mn1.5O4 discharges 118.3 mAh g(-1) capacity and 4.7 V voltage plateau, which is comparable to the sample synthesized using commercial electrolytic MnO2. This process can recover the substances in the spent Zn-Mn batteries and innocuously treat the wastewaters, indicating that it is environmentally acceptable and applicable. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Smart, M. C.; Ratnakumar, B. V.; West, W. C.; Brandon, E. J.
2011-01-01
Objectives and Approach: (1) Develop advanced Li ]ion electrolytes that enable cell operation over a wide temperature range (i.e., -60 to +60 C). Improve the high temperature stability and lifetime characteristics of wide operating temperature electrolytes. (2) Define the performance limitations at low and high temperature extremes, as well as, life limiting processes. (3) Demonstrate the performance of advanced electrolytes in large capacity prototype cells.
Solid colloidal optical wavelength filter
Alvarez, Joseph L.
1992-01-01
A solid colloidal optical wavelength filter includes a suspension of spheal particles dispersed in a coagulable medium such as a setting plastic. The filter is formed by suspending spherical particles in a coagulable medium; agitating the particles and coagulable medium to produce an emulsion of particles suspended in the coagulable medium; and allowing the coagulable medium and suspended emulsion of particles to cool.