Sample records for electromagnetic compatibility emc

  1. Statistical EMC: A new dimension electromagnetic compatibility of digital electronic systems

    NASA Astrophysics Data System (ADS)

    Tsaliovich, Anatoly

    Electromagnetic compatibility compliance test results are used as a database for addressing three classes of electromagnetic-compatibility (EMC) related problems: statistical EMC profiles of digital electronic systems, the effect of equipment-under-test (EUT) parameters on the electromagnetic emission characteristics, and EMC measurement specifics. Open area test site (OATS) and absorber line shielded room (AR) results are compared for equipment-under-test highest radiated emissions. The suggested statistical evaluation methodology can be utilized to correlate the results of different EMC test techniques, characterize the EMC performance of electronic systems and components, and develop recommendations for electronic product optimal EMC design.

  2. Manager's Role in Electromagnetic Interference (EMI) Control

    NASA Technical Reports Server (NTRS)

    Sargent, Noel B.; Lewis, Catherine C.

    2013-01-01

    This presentation captures the essence of electromagnetic compatibility (EMC) engineering from a project manager's perspective. It explains the basics of EMC and the benefits to the project of early incorporation of EMC best practices. The EMC requirement products during a project life cycle are identified, along with the requirement verification methods that should be utilized. The goal of the presentation is to raise awareness and simplify the mystique surrounding electromagnetic compatibility for managers that have little or no electromagnetics background

  3. EMC analysis of MOS-1

    NASA Astrophysics Data System (ADS)

    Ishizawa, Y.; Abe, K.; Shirako, G.; Takai, T.; Kato, H.

    The electromagnetic compatibility (EMC) control method, system EMC analysis method, and system test method which have been applied to test the components of the MOS-1 satellite are described. The merits and demerits of the problem solving, specification, and system approaches to EMC control are summarized, and the data requirements of the SEMCAP (specification and electromagnetic compatibility analysis program) computer program for verifying the EMI safety margin of the components are sumamrized. Examples of EMC design are mentioned, and the EMC design process and selection method for EMC critical points are shown along with sample EMC test results.

  4. 77 FR 16925 - Medical Devices; Neurological Devices; Classification of the Near Infrared Brain Hematoma Detector

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-23

    ... Mitigation measures Excessive laser power Electrical safety and electromagnetic compatibility (EMC... should validate electromagnetic compatibility (EMC), electrical safety, and battery characteristics; (4...

  5. Morgantown People Mover Electromagnetic Compatibility Program

    DOT National Transportation Integrated Search

    1980-09-01

    Electromagnetic Compatibility (EMC) of a transit system is the absence of interference between all parts of the system, and between the system and the community which it serves. This report documents the EMC experience obtained during the design and ...

  6. Integrated Advanced Microwave Sounding Unit-A (AMSU-A. Engineering Report: Electromagnetic Interface (EMI)/Electromagnetic Radiation (EMR) and Electromagnetic Compatibility (EMC), for the METSAT/METOP AMSU-A1

    NASA Technical Reports Server (NTRS)

    Valdez, A.

    1999-01-01

    This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Electromagnetic Interference (EMI), Electromagnetic Susceptibility, and Electromagnetic Compatibility (EMC) qualification test for the Meteorological Satellite (METSAT) and the Meteorological Operation Platform (METOP) projects. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/5D. This document describes the EMI/EMC test performed by Aerojet and it is presented in the following manner: Section-1 contains introductory material and a brief summary of the test results. Section 2 contains more detailed descriptions of the test plan, test procedure, and test results for each type of EMI/EMC test conducted. Section 3 contains supplementary information that includes test data sheets, plots, and calculations collected during the qualification testing.

  7. International Symposium on Electromagnetic Compatibility, 25th, Arlington, VA, August 23-25, 1983, Symposium Record

    NASA Astrophysics Data System (ADS)

    Subjects related to electromagnetic compatibility (EMC) analysis are discussed, taking into account forcing terms of line equations for externally excited transmission lines, E-fields over ground, electromagnetic near fields as a function of electrical size, a program for experimental verification of EMC analysis models, random susceptability of an IC 7400 TTL NAND gate, and a comparison of IEMCAP and SEMCAP. Other topics explored are concerned with EMC measurements, spectrum management, the electromagnetic pulse (EMP), a Navy EMC program, measurement systems, filters, EMC design, electromagnetic vulnerability (EMV) assessment of weapon systems, FCC rules and regulations, shielding, and electromagnetic interference (EMI) in communication systems. Attention is also given to nonsinusoidal functions in radar and communications, transients/electrostatic discharge, open field testing, cables and connectors, interference effects of induced and conducted earth current at dc and ELF, test cells, and cable coupling.

  8. Aircraft electromagnetic compatibility

    NASA Technical Reports Server (NTRS)

    Clarke, Clifton A.; Larsen, William E.

    1987-01-01

    Illustrated are aircraft architecture, electromagnetic interference environments, electromagnetic compatibility protection techniques, program specifications, tasks, and verification and validation procedures. The environment of 400 Hz power, electrical transients, and radio frequency fields are portrayed and related to thresholds of avionics electronics. Five layers of protection for avionics are defined. Recognition is given to some present day electromagnetic compatibility weaknesses and issues which serve to reemphasize the importance of EMC verification of equipment and parts, and their ultimate EMC validation on the aircraft. Proven standards of grounding, bonding, shielding, wiring, and packaging are laid out to help provide a foundation for a comprehensive approach to successful future aircraft design and an understanding of cost effective EMC in an aircraft setting.

  9. Test plan/procedure for the checkout of the USA cable communications test configuration for the electromagnetic compatibility (EMC) tests

    NASA Technical Reports Server (NTRS)

    Perry, J. C.

    1975-01-01

    A series of electromagnetic compatibility (EMC) tests were conducted in May, 1975 in the Soviet Union. The purpose of the EMC tests was to determine the effects of the operating environment of the Soviet aircraft, Soyuz, upon the electrical performance of the USA's cable communications equipment located in Soyuz. The test procedures necessary to check out the cable communications test configuration in preparation for the EMC tests are presented.

  10. Overview on the standardization in the field of electromagnetic compatibility

    NASA Astrophysics Data System (ADS)

    Goldberg, Georges

    1989-04-01

    Standardization in the domain of electromagnetic compatibility (EMC) is discussed, with specific reference to the standards of the International Electrotechnical Commission, the Comite International Special des Perturbations Radioelectriques, and the Comite Europeen de Normalisation Electrotechnique. EMC fields considered include radiocommunications, telecommunications, biological effects, and data transmission. Standards are presented for such electromagnetic disturbances as low-frequency, high-frequency, conduction, and radiation phenomena.

  11. C3I system modification and EMC (electromagnetic compatibility) methodology, volume 1

    NASA Astrophysics Data System (ADS)

    Wilson, J. L.; Jolly, M. B.

    1984-01-01

    A methodology (i.e., consistent set of procedures) for assessing the electromagnetic compatibility (EMC) of RF subsystem modifications on C3I aircraft was generated during this study (Volume 1). An IEMCAP (Intrasystem Electromagnetic Compatibility Analysis Program) database for the E-3A (AWACS) C3I aircraft RF subsystem was extracted to support the design of the EMC assessment methodology (Volume 2). Mock modifications were performed on the E-3A database to assess, using a preliminary form of the methodology, the resulting EMC impact. Application of the preliminary assessment methodology to modifications in the E-3A database served to fine tune the form of a final assessment methodology. The resulting final assessment methodology is documented in this report in conjunction with the overall study goals, procedures, and database. It is recommended that a similar EMC assessment methodology be developed for the power subsystem within C3I aircraft. It is further recommended that future EMC assessment methodologies be developed around expert systems (i.e., computer intelligent agents) to control both the excruciating detail and user requirement for transparency.

  12. Development of Design Standards and Guidelines for Electromagnetic Compatibility and Lightning Protection for Spacecraft Utilizing Composite Materials

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Preliminary design guidelines necessary to assure electromagnetic compatibility (EMC) of spacecraft using composite materials, are presented. A database of electrical properties of composite materials which may have an effect on EMC is established. The guidelines concentrate on the composites that are conductive but may require enhancement to be adequate for EMC purposes. These composites are represented by graphite reinforced polymers. Methods for determining adequate conductivity levels for various EMC purposes are defined, along with the methods of design which increase conductivity of composite materials and joints to adequate levels.

  13. Electromagnetic compatibility of PLC adapters for in-home/domestic networks

    NASA Astrophysics Data System (ADS)

    Potisk, Lukas; Hallon, Jozef; Orgon, Milos; Fujdiak, Radek

    2018-01-01

    The use of programable logic controllers (PLC) technology in electrical networks 230 V causes electromagnetic radiation that interferes with other electrical equipment connected to the network [1-4]. Therefore, this article describes the issues of electromagnetic compatibility (EMC) of new PLC adapters used in IP broadband services in a multi-user environment. The measurements of disturbing electromagnetic field originated in PLC adapters were made in a certified laboratory EMC (laboratory of electromagnetic compatibility) in the Institute of Electrical Engineering at Faculty of Electrical Engineering and Information Technology of the Slovak University of Technology in Bratislava. The measured spectra of the radiated electromagnetic field will be compared with the results obtained when testing older PLC modems [5].

  14. Automation of electromagnetic compatability (EMC) test facilities

    NASA Technical Reports Server (NTRS)

    Harrison, C. A.

    1986-01-01

    Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.

  15. UMTA Rail Transit EMI/EMC Program : An Overview and Summary

    DOT National Transportation Integrated Search

    1987-02-01

    This report gives a history of the UMTA Rail Transit Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMC) program, together with a listing of significant achievements over the life of the program. This is the lead volume of a nine...

  16. Electromagnetic Compatibility Testing of Implantable Neurostimulators Exposed to Metal Detectors

    PubMed Central

    Seidman, Seth J; Kainz, Wolfgang; Casamento, Jon; Witters, Donald

    2010-01-01

    This paper presents results of electromagnetic compatibility (EMC) testing of three implantable neurostimulators exposed to the magnetic fields emitted from several walk-through and hand-held metal detectors. The motivation behind this testing comes from numerous adverse event reports involving active implantable medical devices (AIMDs) and security systems that have been received by the Food and Drug Administration (FDA). EMC testing was performed using three neurostimulators exposed to the emissions from 12 walk-through metal detectors (WTMDs) and 32 hand-held metal detectors (HHMDs). Emission measurements were performed on all HHMDs and WTMDs and summary data is presented. Results from the EMC testing indicate possible electromagnetic interference (EMI) between one of the neurostimulators and one WTMD and indicate that EMI between the three neurostimulators and HHMDs is unlikely. The results suggest that worst case situations for EMC testing are hard to predict and testing all major medical device modes and setting parameters are necessary to understand and characterize the EMC of AIMDs. PMID:20448818

  17. Test operations procedure (TOP) 1-2-512 electromagnetic compatibility tests

    NASA Astrophysics Data System (ADS)

    1995-05-01

    This TOP provides guidance for the planning, execution, and reporting of grounding and bonding and electromagnetic compatibility (EMC) tests of electrical, electronic, and electrochemical equipment, subsystems, and systems.

  18. Electromagnetic Compatibility (EMC) in Microelectronics.

    DTIC Science & Technology

    1983-02-01

    Fault Tree Analysis", System Saftey Symposium, June 8-9, 1965, Seattle: The Boeing Company . 12. Fussell, J.B., "Fault Tree Analysis-Concepts and...procedure for assessing EMC in microelectronics and for applying DD, 1473 EOiTO OP I, NOV6 IS OESOL.ETE UNCLASSIFIED SECURITY CLASSIFICATION OF THIS...CRITERIA 2.1 Background 2 2.2 The Probabilistic Nature of EMC 2 2.3 The Probabilistic Approach 5 2.4 The Compatibility Factor 6 3 APPLYING PROBABILISTIC

  19. Basic EMC (Electromagnetic Compatibility) Technology Advancement for C3 Systems - Model Revision for IEMCAP (Intrasystem Electromagnetic Compatibility Analysis Program).

    DTIC Science & Technology

    1984-10-01

    8217:- . . . .:- . . . * *. . - . . -’" - *. - . " . * - -A REFERENCES [1] J. L. Bogdanor , et. al., Intrasystem Electromagnetic Compatibility Analy- sis Program, Technical Report, RADC-TR-74...286, Vol. IV A, Rome Air -.- Development Center, Griffiss AFB, NY, November 1982. [30] J0 B. Bogdanor , M. D. Siegel, G. L. Weinstock, Intra-Vehicle

  20. JTIDS electromagnetic compatibility in the 960-1215 MHz band

    NASA Astrophysics Data System (ADS)

    Lokuta, Robert S.

    1992-01-01

    The Joint Tactical Information Distribution System (JTIDS) operates in the 960-1215 MHz frequency band. This band is allocated world-wide on a primary basis for aeronautical radio navigation. JTIDS was designed to be electromagnetically compatible with the Air Traffic Control systems that operate in this band. Over the past 15 years, extensive bench tests, flight tests, and analyses were conducted to assess the electromagnetic compatibility (EMC) of JTIDS in the 960-1215 MHz band. This report summarizes the results and conclusions of these efforts, presents some supporting data and provides specific guidance for the operation of JTIDS within the National Air Space. Guidance and recommendations are also provided to assist in the definition and scope of a JTIDS EMC test and analysis effort.

  1. Electromagnetic Compatibility Design of the Computer Circuits

    NASA Astrophysics Data System (ADS)

    Zitai, Hong

    2018-02-01

    Computers and the Internet have gradually penetrated into every aspect of people’s daily work. But with the improvement of electronic equipment as well as electrical system, the electromagnetic environment becomes much more complex. Electromagnetic interference has become an important factor to hinder the normal operation of electronic equipment. In order to analyse the computer circuit compatible with the electromagnetic compatibility, this paper starts from the computer electromagnetic and the conception of electromagnetic compatibility. And then, through the analysis of the main circuit and system of computer electromagnetic compatibility problems, we can design the computer circuits in term of electromagnetic compatibility. Finally, the basic contents and methods of EMC test are expounded in order to ensure the electromagnetic compatibility of equipment.

  2. Guidelines for Electromagnetic Interference Testing of Power Plant Equipment: Revision 3 to TR-102323

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Cunningham and J. Shank

    2004-11-01

    To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I&C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner.

  3. Electromagnetic Compatibility between Marine Automatic Identification and Public Correspondence Systems in the Maritime Mobile VHF Band.

    DOT National Transportation Integrated Search

    2000-04-01

    The Coast Guard funded the National Telecommunications and Information Administration : (NTIA) to perform electromagnetic compatibility (EMC) tests between an ITU-R M. 825-3 : (Characteristics Of a Transponder System Using Digital Selective Calling T...

  4. EMC (Electromagnetic Compatibility) System Test and Analysis Interface.

    DTIC Science & Technology

    1983-05-01

    D- R136 64 EMC (ELECTROARGNETIC COMPATIBILITY) SYSTEM TEST AND V ANALYSIS INTE FACE(J) BOEING CO SEATTLE WA E F BALL ET AL MAY 93 RRDC-TR-83-121...RADC-TR-83- 121 Final Tedical Report May 1963 EMC SYSTEM TEST AND ANAL YSIS INTERFACE_ The Boeing Company E. F. Ball, L. Knutson and B. L...Carlson *. . APPROVE FOR PUBLIC REESEk DIS TRIBUTION ULMTED D IS -ELECTE ,... DEC 20 1983 >- D" c: ROME AIR DEVELOPMENT CENTER * Air Force Systems Command

  5. Testing for EMC (electromagnetic compatibility) in the clinical environment.

    PubMed

    Paperman, D; David, Y; Martinez, M

    1996-01-01

    Testing for electromagnetic compatibility (EMC) in the clinical environment introduces a host of complex conditions not normally encountered under laboratory conditions. In the clinical environment, various radio-frequency (RF) sources of electromagnetic interference (EMI) may be present throughout the entire spectrum of interest. Isolating and analyzing the impact from the sources of interference to medical devices involves a multidisciplinary approach based on training in, and knowledge of, the following: operation of medical devices and their susceptibility to EMI; RF propagation modalities and interaction theory; spectrum analysis systems and techniques (preferably with signature analysis capabilities) and calibrated antennas; the investigation methodology of suspected EMC problems, and testing protocols and standards. Using combinations of standard test procedures adapted for the clinical environment with personnel that have an understanding of radio-frequency behavior increases the probability of controlling, proactively, EMI in the clinical environment, thus providing for a safe and more effective patient care environment.

  6. Magnetic Cleanliness Program Under Control of Electromagnetic Compatibility for the SELENE (Kaguya) Spacecraft

    NASA Astrophysics Data System (ADS)

    Matsushima, Masaki; Tsunakawa, Hideo; Iijima, Yu-Ichi; Nakazawa, Satoru; Matsuoka, Ayako; Ikegami, Shingo; Ishikawa, Tomoaki; Shibuya, Hidetoshi; Shimizu, Hisayoshi; Takahashi, Futoshi

    2010-07-01

    To achieve the scientific objectives related to the lunar magnetic field measurements in a polar orbit at an altitude of 100 km, strict electromagnetic compatibility (EMC) requirements were applied to all components and subsystems of the SELENE (Kaguya) spacecraft. The magnetic cleanliness program was defined as one of the EMC control procedures, and magnetic tests were carried out for most of the engineering and flight models. The EMC performance of all components was systematically controlled and examined through a series of EMC tests. As a result, the Kaguya spacecraft was made to be very clean, magnetically. Hence reliable scientific data related to the magnetic field around the Moon were obtained by the LMAG (Lunar MAGnetometer) and the PACE (Plasma energy Angle and Composition Experiment) onboard the Kaguya spacecraft. These data have been available for lunar science use since November 2009.

  7. International Symposium on Electromagnetic Compatibility, Wakefield, MA, August 20-22, 1985, Record

    NASA Astrophysics Data System (ADS)

    Various papers on electromagnetic compatibility are presented. The general topics addressed include: EMI transient/impulsive disturbances, electromagnetic shielding, antennas and propagation, measurement technology, anechoic chamber/open site measurements, communications systems, electrostatic discahrge, cables/transmission lines. Also considered are: elecromagnetic environments, antennas, electromagnetic pulse, nonlinear effect, computer/data transmission systems, EMI standards and requirements, enclosures/TEM cells, systems EMC, and test site measurements.

  8. Primary experimental study on safety of deep brain stimulation in RF electromagnetic field.

    PubMed

    Jun, Xu; Luming, Li; Hongwei, Hao

    2009-01-01

    With the rapid growth of clinical application of Deep Brain Stimulation, its safety and functional concern in the electromagnetic field, another pollution becoming much more serious, has become more and more significant. Meanwhile, the measuring standards on Electromagnetic Compatibility (EMC) for DBS are still incomplete. Particularly, the knowledge of the electromagnetic field induced signals on the implanted lead is ignorant while some informal reports some side effects. This paper briefly surmised the status of EMC standards on implantable medical devices. Based on the EMC experiments of DBS device we developed, two experiments for measuring the induced voltage of the deep brain stimulator in RF electromagnetic field were reported. The measured data showed that the induced voltage in some frequency was prominent, for example over 2V. As a primary research, we think these results would be significant to cause researcher to pay more attention to the EMC safety problem and biological effects of the induced voltage in deep brain stimulation and other implantable devices.

  9. The Ships Below-Decks Electromagnetic Compatibility (EMC) Program. A compilation of Papers Presented at the 1987 IEEE International Symposium on EMC

    DTIC Science & Technology

    1987-09-30

    were producing below-deck environ - such that after 24 hours the performance loss ranged mental levels exceeding the "normal" environmental from 13 to...SGA performance environmental EMI testing in the electromagnetically measurements b- made in the laboratory. However, it quiet laboratory environments ... Environmentally Sealed SGAs.................................... 1-1 Need for Long Term SGA Performance Evaluation .................... 1-2 Performance

  10. Electromagnetic Compatibility for the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Scully, Robert C.

    2004-01-01

    This slide presentation reviews the Space Shuttle electromagnetic compatibility (EMC). It includes an overview of the design of the shuttle with the areas that are of concern for the electromagnetic compatibility. It includes discussion of classical electromagnetic interference (EMI) and the work performed to control the electromagnetic interference. Another area of interest is electrostatic charging and the threat of electrostatic discharge and the attempts to reduce damage to the Shuttle from these possible hazards. The issue of electrical bonding is als reviewed. Lastly the presentation reviews the work performed to protect the shuttle from lightning, both in flight and on the ground.

  11. Reverberant Microwave Propagation

    DTIC Science & Technology

    2008-10-01

    HERO Hazards of Electromagnetic Radiation to Ordnance HP Hewlett Packard HWD Half-Wave Dipole IEC International Electrotechnical Commission IEE...composite panels used in new ship design; Hazards of Electromagnetic Radiation to Ordnance ( HERO ) analyses; and digital wireless system performance...Electro-Explosive Device EMC Electromagnetic Compatibility ft Foot (feet) GHz Gigahertz HERO Hazards of Electromagnetic

  12. Electromagnetic environmental criteria for US Army missile systems - EMC, EMR, EMI, EMP, ESD, and lightning

    NASA Astrophysics Data System (ADS)

    Ponds, Charles D.; Knaur, James A.

    1988-01-01

    This paper presents the design and test requirements in developing an electromagnetic compatibility missile system. Environmental levels are presented for electromagnetic radiation hazards, electromagnetic radiation operational, electrostatic discharge, lightning, and electromagnetic pulse (nuclear). Testing techniques and facility capabilities are presented for research and development testing of missile systems.

  13. Shuttle Communications and Tracking, Avionics, and Electromagnetic Compatibility

    NASA Technical Reports Server (NTRS)

    deSilva, K.; Hwu, Shian; Kindt, Kaylene; Kroll, Quin; Nuss, Ray; Romero, Denise; Schuler, Diana; Sham, Catherine; Scully, Robert

    2011-01-01

    By definition, electromagnetic compatibility (EMC) is the capability of components, sub-systems, and systems, to operate in their intended electromagnetic environment, within an established margin of safety, and at design levels of performance. Practice of the discipline itself incorporates knowledge of various aspects of applied physics, materials science, and engineering across the board, and includes control and mitigation of undesirable electromagnetic interaction between intentional and unintentional emitters and receivers of radio frequency energy, both within and external to the vehicle; identification and control of the hazards of non-ionizing electromagnetic radiation to personnel, ordnance, and fuels and propellants; and vehicle and system protection from the direct and indirect effects of lightning and various other forms of electrostatic discharge (ESD) threats, such as triboelectrification and plasma charging. EMC is extremely complex and far-reaching, affecting in some degree every aspect of the vehicle s design and operation. The most successful efforts incorporate EMC design features and techniques throughout design and fabrication of the vehicle s structure and components, as well as appropriate operational considerations with regard to electromagnetic threats in the operational environment, from the beginning of the design effort to the end of the life cycle of the manufactured product. This approach yields the highest design performance with the lowest cost and schedule impact.

  14. EMC (Electromagnetic Compatibility) Standards Handbook. Revision 4,

    DTIC Science & Technology

    1982-11-01

    report was prepared by the lIT Research Institute as part of AF Project 649E under Contract F-19628-80-C-0042 with the Electronic Systems Division of...the Air Pbrce Systems Command in support of the DoD Electromagnetic Compatibility Analysis Center, Annapolis, Maryland. This report has been reviewed...3-1 "JVDE Organizations .. .0 . . . . . . . . . . . . . . . . . . . . . 3 1 VDE Testing Station

  15. IEEE 1990 International Symposium on Electromagnetic Compatibility, Washington, DC, Aug. 21-23, 1990, Record

    NASA Astrophysics Data System (ADS)

    The present conference discusses topics in EM shielding effectiveness, system-level EMC, EMP effects, circuit-level EMI testing, EMI control, analysis techniques for system-level EMC, EMP protective measures, EMI test methods, electrostatic-discharge testing, printed circuit-board design for EMC, and EM environment effects. Also discussed are EMI measurement procedures, EM spectrum-management issues for the 21st century, antenna and propagation effects on EMI testing, EMI control in cables, socioeconomic aspects of EMC, systemwide EMI controls, and EM radiation and coupling.

  16. Electromagnetic Compatibility Analysis Group VA-H3

    NASA Technical Reports Server (NTRS)

    Armanda, Carlos A.

    2008-01-01

    During the eight weeks working at NASA, I was fortunate enough to work with the Expendable Launch Vehicle's (ELV) Electromagnetic Compatibility (EMC) Team, who is responsible for the evaluation and analysis of any EMI risk an ELV mission might face. This group of people concern themselves with practically any form of electromagnetic interference that may risk the safety of a rocket, a mission, or even people. Taking this into consideration, the group investigates natural forms of interference, such as lightning, to manmade interferences, such as antennas.

  17. Electromagnetic Compatibility (EMC) for Integration and Use of Near Field Communication (NFC) in Aircraft

    NASA Astrophysics Data System (ADS)

    Nalbantoglu, Cemal; Kiehl, Thorsten; God, Ralf; Stadtler, Thiemo; Kebel, Robert; Bienert, Renke

    2016-05-01

    For portable electronic devices (PEDs), e.g. smartphones or tablets, near field communication (NFC) enables easy and convenient man-machine interaction by simply tapping a PED to a tangible NFC user interface. Usage of NFC technology in the air transport system is supposed to facilitate travel processes and self-services for passengers and to support digital interaction with other participating stakeholders. One of the potential obstacles to benefit from NFC technology in the aircraft cabin is the lack of an explicit qualification guideline for electromagnetic compatibility (EMC) testing. In this paper, we propose a methodology for EMC testing and for characterizing NFC devices and their emissions according to aircraft industry standards (RTCA DO-160, DO-294, DO-307 and EUROCAE ED- 130). A potential back-door coupling scenario of radiated NFC emissions and possible effects to nearby aircraft wiring are discussed. A potential front-door- coupling effect on NAV/COM equipment is not investigated in this paper.

  18. Automatic EMC test system

    NASA Astrophysics Data System (ADS)

    Kasai, R.; Abe, T.; Sano, T.

    Automated electromagnetic compatibility (EMC) tests for spacecraft hardware are described. EMC tests are divided into three categories: compensating measurement and calibration errors, comparison of test results with specification, and fine-frequency searching using predictive interference analysis. The automated system features an RF receiver and transmitter, a control system, and antennas. Trials are run with conducted and radiated emissions and conducted and radiated susceptibility over a frequency range of 0.1-40 GHz with narrow, broad and random broad band noise. The system meets military specifications 1541, 461, and 462.

  19. Small Diameter Bomb Increment II (SDB II)

    DTIC Science & Technology

    2013-12-01

    in 2013: Electromagnetic Environments and Effects and Hazards of Electromagnetic Radiation to Ordnance . Reliability Growth Testing started in June...unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 SDB II December 2013 SAR April 16, 2014 17:24:29...Framework EMC - Electromagnetic Compatibility EMI - Electromagnetic Interference GESP - GIG Enterprise Service Profiles GIG - Global Information Grid i.e

  20. Investigation of Electromagnetic Signatures of a FPGA Using an APREL EM-ISIGHT System

    DTIC Science & Technology

    2015-12-01

    unprofessional workmanship in the bonding process. Focused ion beam (FIB) images often consist of some type of etch and/or deposition of material from/to...characteristics of conducted emissions." Electromagnetic Compatibility, 2008. EMC 2008. IEEE International Symposium (2008): 1-4. Montanari, Ivan

  1. System Guidelines for EMC Safety-Critical Circuits: Design, Selection, and Margin Demonstration

    NASA Technical Reports Server (NTRS)

    Lawton, R. M.

    1996-01-01

    Demonstration of safety margins for critical points (circuits) has traditionally been required since it first became a part of systems-level Electromagnetic Compatibility (EMC) requirements of MIL-E-6051C. The goal of this document is to present cost-effective guidelines for ensuring adequate Electromagnetic Effects (EME) safety margins on spacecraft critical circuits. It is for the use of NASA and other government agencies and their contractors to prevent loss of life, loss of spacecraft, or unacceptable degradation. This document provides practical definition and treatment guidance to contain costs within affordable limits.

  2. Potential Damage to Flight Hardware from MIL-STD-462 CS02 Setup

    NASA Technical Reports Server (NTRS)

    Harris, Patrick K.; Block, Nathan F.

    2002-01-01

    The MIL-STD-462 CS02 conducted susceptibility test setup, performed during electromagnetic compatibility (EMC) testing, consists of an audio transformer with the secondary used as an inductor and a large capacitor. Together, these two components form an L-type low-pass filter to minimize the injected test signal input into the power source. Some flight hardware power input configurations are not compatible with this setup and break into oscillation when powered up. This can damage flight hardware and caused a catastrophic failure to an item tested in the Goddard Space Flight Center (GSFC) Large EMC Test Facility.

  3. Suppression of radiating harmonics Electro-Impulse Deicing (EIDI) systems

    NASA Astrophysics Data System (ADS)

    Zieve, Peter; Ng, James; Fiedberg, Robert

    1991-10-01

    The electromagnetic compatibility (EMC) of two different configurations of electromagnetic deicing systems is discussed. Both Electro-Impulse Deicing (EIDI) and Eddy Current Repulsion Deicing Strip (EDS) are investigated. With EIDI, rigid coils are mounted behind the wing; while with EDS, the impulse coils are built thin and flexible with printed circuit board technology. An important consideration in the certification of electromagnetic impulse deicing systems is electromagnetic compatibility (EMC). When the capacitor bank discharges, a large current pulse travels down a transmission line to the coil. The coil is one source of radiation. Another source is the cabling and connections to the coil. In work conducted for the FAA in 1988, it was found that excessive electromagnetic emissions resulted from the operation of a Low Voltage Electro-Impulse Deicer (LVEID) in conjunction with a composite wing. The goal of this project was to investigate and develop techniques for controlling emissions without the benefit of shielding. In this study it was determined that both EIDI and EDS could be brought within the RTCA/DO-160B standards through proper shielding and termination of the pulse power cable. An alternative topology of EDS with the impulse coil on the wing exterior surface did not meet the standard.

  4. Space and Missile Systems Center Standard: Test Requirements for Ground Systems

    DTIC Science & Technology

    2013-09-30

    Human Exposure to Radio Frequency Electromagnetic Fields , 3kHz to...5] Federal Code of Regulations FCC Part 15 Federal Code of Regulations, Title 47: Telecommunication, Part 15– Radio Frequency Devices 2.3 Non...DT&E Development test and evaluation EMC Electromagnetic compatibility FAT Factory acceptance test FCA Functional configuration audit FCC

  5. Feasibility results of an electromagnetic compatibility test protocol to evaluate medical devices to radio frequency identification exposure

    PubMed Central

    2014-01-01

    Background The use of radio frequency identification (RFID) systems in healthcare is increasing, and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have demonstrated that RFID systems can interfere with medical devices; however, the majority of past studies relied on time-consuming and burdensome test schemes based on ad hoc test methods applied to individual RFID systems. Methods This paper presents the results of using an RFID simulator that allows for faster evaluation of RFID-medical device EMC against a library of RFID test signals at various field strengths. Results The results of these tests demonstrate the feasibility and adequacy of simulator testing and can be used to support its incorporation into applicable consensus standards. Conclusions This work can aid the medical device community in better assessing the risks associated with medical device exposure to RFID. PMID:25086451

  6. Feasibility results of an electromagnetic compatibility test protocol to evaluate medical devices to radio frequency identification exposure.

    PubMed

    Seidman, Seth J; Bekdash, Omar; Guag, Joshua; Mehryar, Maryam; Booth, Paul; Frisch, Paul

    2014-08-03

    The use of radio frequency identification (RFID) systems in healthcare is increasing, and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have demonstrated that RFID systems can interfere with medical devices; however, the majority of past studies relied on time-consuming and burdensome test schemes based on ad hoc test methods applied to individual RFID systems. This paper presents the results of using an RFID simulator that allows for faster evaluation of RFID-medical device EMC against a library of RFID test signals at various field strengths. The results of these tests demonstrate the feasibility and adequacy of simulator testing and can be used to support its incorporation into applicable consensus standards. This work can aid the medical device community in better assessing the risks associated with medical device exposure to RFID.

  7. Experimental investigations and guidelines for PCB design for a fuel injection ECU to meet automotive environmental, EMI/EMC and ESD standards

    NASA Astrophysics Data System (ADS)

    Kalyankar-Narwade, Supriya; Kumar, C. Ramesh; Patil, Sanjay A.

    2017-11-01

    Engine Management ECU plays a vital role in controlling different important features related to the engine performance. ECU is an embedded system which includes hardware and firmware platform for control logics. However, it is necessary to verify its smooth performance by its functionality testing in the Electromagnetic environment for approval. If these requirements are not known at earlier stages, then ECU may not fulfil functional requirements during required automotive electronic test standards. Hence, focusing on EMS ECU, this paper highlights hardware, layout and software guidelines for solving problems related with Electromagnetic Interference (EMI) to comply ISO 7637, CISPR 25 standard, Electromagnetic Compatibility (EMC) to comply ISO 11452-4,5 standard, Electrostatic Discharge (ESD) to comply ISO 10605 standard and Environmental Testing to comply standards as per IEC standards. This paper specifies initially the importance, need and guidelines for reducing the EMI effect on PCB i.e. making ECU more electromagnetically compatible as per automotive standards. The guidelines are useful for the designers to avoid pitfalls at the later stage. After mentioned modifications in the paper, ECU successfully passed the requirements for all standard tests.

  8. Development of automated electromagnetic compatibility test facilities at Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    Harrison, Cecil A.

    1986-01-01

    The efforts to automate the electromagentic compatibility (EMC) test facilites at Marshall Flight Center were examined. A battery of nine standard tests is to be integrated by means of a desktop computer-controller in order to provide near real-time data assessment, store the data acquired during testing on flexible disk, and provide computer production of the certification report.

  9. 20 kHz main inverter unit. [for space station power supplies

    NASA Technical Reports Server (NTRS)

    Hussey, S.

    1989-01-01

    A proof-of-concept main inverter unit has demonstrated the operation of a pulse-width-modulated parallel resonant power stage topology as a 20-kHz ac power source driver, showing simple output regulation, parallel operation, power sharing and short-circuit operation. The use of a two-stage dc input filter controls the electromagnetic compatibility (EMC) characteristics of the dc power bus, and the use of an ac harmonic trap controls the EMC characteristics of the 20-kHz ac power bus.

  10. Computational Electromagnetics Application to Small Geometric Anomalies and Associated Ucertainty Evaluation

    DTIC Science & Technology

    2010-02-28

    implemented a fast method to enable the statistical characterization of electromagnetic interference and compatibility (EMI/EMC) phenomena on electrically...higher accuracy is needed, e.g., to compute higher moment statistics . To address this problem, we have developed adaptive stochastic collocation methods ...SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) AF OFFICE OF SCIENTIFIC RESEARCH 875 N. RANDOLPH ST. ROOM 3112 ARLINGTON VA 22203 UA

  11. Wireless Coexistence and EMC of Bluetooth and 802.11b Devices in Controlled Laboratory Settings

    PubMed Central

    Seidman, Seth; Kainz, Wolfgang; Ruggera, Paul; Mendoza, Gonzalo

    2011-01-01

    This paper presents experimental testing that has been performed on wireless communication devices as victims of electromagnetic interference (EMI). Wireless victims included universal serial bus (USB) network adapters and personal digital assistants (PDAs) equipped with IEEE 802.11b and Bluetooth technologies. The experimental data in this paper was gathered in an anechoic chamber and a gigahertz transverse electromagnetic (GTEM) cell to ensure reliable and repeatable results. This testing includes: Electromagnetic compatibility (EMC) testing performed in accordance with IEC 60601-1-2, an in-band sweep of EMC testing, and coexistence testing. The tests in this study show that a Bluetooth communication was able to coexist with other Bluetooth devices with no decrease in throughput and no communication breakdowns. However, testing revealed a significant decrease in throughput and increase in communication breakdowns when an 802.11b source is near an 802.11b victim. In a hospital setting decreased throughput and communication breakdowns can cause wireless medical devices to fail. It is therefore vital to have an understanding of the effect EMI can have on wireless communication devices. PMID:22043254

  12. Wireless Coexistence and EMC of Bluetooth and 802.11b Devices in Controlled Laboratory Settings.

    PubMed

    Seidman, Seth; Kainz, Wolfgang; Ruggera, Paul; Mendoza, Gonzalo

    2011-01-01

    This paper presents experimental testing that has been performed on wireless communication devices as victims of electromagnetic interference (EMI). Wireless victims included universal serial bus (USB) network adapters and personal digital assistants (PDAs) equipped with IEEE 802.11b and Bluetooth technologies. The experimental data in this paper was gathered in an anechoic chamber and a gigahertz transverse electromagnetic (GTEM) cell to ensure reliable and repeatable results. This testing includes: Electromagnetic compatibility (EMC) testing performed in accordance with IEC 60601-1-2, an in-band sweep of EMC testing, and coexistence testing. The tests in this study show that a Bluetooth communication was able to coexist with other Bluetooth devices with no decrease in throughput and no communication breakdowns. However, testing revealed a significant decrease in throughput and increase in communication breakdowns when an 802.11b source is near an 802.11b victim. In a hospital setting decreased throughput and communication breakdowns can cause wireless medical devices to fail. It is therefore vital to have an understanding of the effect EMI can have on wireless communication devices.

  13. Electromagnetic compatibility (EMC) assurance of automotive signal/data transmission for vehicle transportation systems.

    DOT National Transportation Integrated Search

    2012-03-31

    This report is the final report of the Center for Transportation & Materials Engineering (CTME) research project funded by the grant (Grant Number: G00000245). The report is submitted to Director of CTME for partial fulfillment for the deliverables o...

  14. EMC Testing on the Integrated Science Instrument Module (ISIM) - A Summary of the EMC Test Campaign for the Science Payload of the James Webb Space Telescope (JWST)

    NASA Technical Reports Server (NTRS)

    McCloskey, John

    2016-01-01

    This paper describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft/observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.

  15. Military Handbook. Grounding, Bonding, and Shielding for Electronic Equipments and Facilities. Volume 2. Applications

    DTIC Science & Technology

    1987-12-29

    EMC, San Francisco CA, 16-18 July 1974, 76-84. 1-13. E. R. Uhlig, "Developmnent of Criteria for Protection ef NIKE -X Power Plant and Facilities...Interference Reduction and Electronic Compatibility, Armour Research Foundation of Illinois Institute of Technology (now IITRI), Chicago IL, October...Measuring Systems Susceptibility," Proceedings of the Eighth Tri-Service Conference on Electromagnetic Compatibility, Armour Research Foundation of

  16. Technical Basis for Electromagnetic Compatibility Regulatory Guidance Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ewing, Paul D.; Korsah, Kofi; Harrison, Thomas J.

    2016-03-01

    The objective of this report is to serve as the technical basis document for the next, planned revision of this RG that highlights and provides the rationale for the recommended changes. The structure of this document follows and summarizes the several assessment activities undertaken during the course of this project to evaluate new and updated electromagnetic compatibility (EMC) standards, testing methods and limits, and relevant technology developments being incorporated into plant activities that may have EMI/RFI implications, as well as other specific issues, including impacts of electrostatic discharge (ESD) on safety equipment and impacts on increased usage of wireless devicesmore » in nuclear power plants.« less

  17. Basic EMC Technology Advancement for C3 Systems - Model Revision for IEMCAP. Volume 5

    DTIC Science & Technology

    1984-10-01

    important asset. 126 REFERENCES [1] J. L. Bogdanor , et. al., Inttasystem Electromagnetic Compatibility Analy- sis Program, Technical Report, RADC-TR-74...Method of Moments, Technical Report, RADC-TR-82-286, Vol. IV A, Rome Air Development Center, Griffiss AFB, NY, November 1982. [30] J. B. Bogdanor , M. D

  18. EMC Test Challenges for NASAs James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    McCloskey, John

    2016-01-01

    This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.

  19. EMC Test Challenges for NASA's James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    McCloskey, John

    2016-01-01

    This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.

  20. Developments in the application of the geometrical theory of diffraction and computer graphics to aircraft inter-antenna coupling analysis

    NASA Astrophysics Data System (ADS)

    Bogusz, Michael

    1993-01-01

    The need for a systematic methodology for the analysis of aircraft electromagnetic compatibility (EMC) problems is examined. The available computer aids used in aircraft EMC analysis are assessed and a theoretical basis is established for the complex algorithms which identify and quantify electromagnetic interactions. An overview is presented of one particularly well established aircraft antenna to antenna EMC analysis code, the Aircraft Inter-Antenna Propagation with Graphics (AAPG) Version 07 software. The specific new algorithms created to compute cone geodesics and their associated path losses and to graph the physical coupling path are discussed. These algorithms are validated against basic principles. Loss computations apply the uniform geometrical theory of diffraction and are subsequently compared to measurement data. The increased modelling and analysis capabilities of the newly developed AAPG Version 09 are compared to those of Version 07. Several models of real aircraft, namely the Electronic Systems Trainer Challenger, are generated and provided as a basis for this preliminary comparative assessment. Issues such as software reliability, algorithm stability, and quality of hardcopy output are also discussed.

  1. Lecture Series on Electromagnetic Interference and Electromagnetic Compatibility Presented on 10-11 June 1991 in Kjeller, Norway, 13-14 June 1991 in Konigswinter, Germany and 17-18 June 1991 in Lisbon, Portugal.

    DTIC Science & Technology

    1991-06-01

    assessing EMC characteristics of EM systems in a lecture on "Measuremazzenvironments and testing".The various test en - vronments available will be described...severe in a dual-diversity system gains at least 10 dB in SNR relative to a maritime situation where salt water corrosion has for many non-diversity...environment having great significance for NATO systems are: (a) electromagnetic interference (EMT) arising from both natural and man-made sources; (b

  2. Electromagnetic compatibility (EMC) standard test chamber upgrade requirements for spacecraft design verification tests

    NASA Technical Reports Server (NTRS)

    Dyer, Edward F.

    1992-01-01

    In view of the serious performance deficiencies inherent in conventional modular and welded shielding EMC test enclosures, in which multipath reflections and resonant standing waves can damage flight hardware during RF susceptibility tests, NASA-Goddard has undertaken the modification of a 20 x 24 ft modular-shielded enclosure through installation of steel panels to which ferrite tiles will be mounted with epoxy. The internally reflected RF energy will thereby be absorbed, and exterior power-line noise will be reduced. Isolation of power-line filters and control of 60-Hz ground connections will also be undertaken in the course of upgrading.

  3. System Guidelines for EMC Safety-Critical Circuits: Design, Selection, and Margin Demonstration

    NASA Technical Reports Server (NTRS)

    Lawton, R. M.

    1996-01-01

    Demonstration of required safety margins on critical electrical/electronic circuits in large complex systems has become an implementation and cost problem. These margins are the difference between the activation level of the circuit and the electrical noise on the circuit in the actual operating environment. This document discusses the origin of the requirement and gives a detailed process flow for the identification of the system electromagnetic compatibility (EMC) critical circuit list. The process flow discusses the roles of engineering disciplines such as systems engineering, safety, and EMC. Design and analysis guidelines are provided to assist the designer in assuring the system design has a high probability of meeting the margin requirements. Examples of approaches used on actual programs (Skylab and Space Shuttle Solid Rocket Booster) are provided to show how variations of the approach can be used successfully.

  4. Correlating the EMC analysis and testing methods for space systems in MIL-STD-1541A

    NASA Technical Reports Server (NTRS)

    Perez, Reinaldo J.

    1990-01-01

    A study was conducted to improve the correlation between the electromagnetic compatibility (EMC) analysis models stated in MIL-STD-1541A and the suggested testing methods used for space systems. The test and analysis methods outlined in MIL-STD-1541A are described, and a comparative assessment of testing and analysis techniques as they relate to several EMC areas is presented. Suggestions on present analysis and test methods are introduced to harmonize and bring the analysis and testing tools in MIL-STD-1541A into closer agreement. It is suggested that test procedures in MIL-STD-1541A must be improved by providing alternatives to the present use of shielded enclosures as the primary site for such tests. In addition, the alternate use of anechoic chambers and open field test sites must be considered.

  5. EMC system test performance on Spacelab

    NASA Astrophysics Data System (ADS)

    Schwan, F.

    1982-07-01

    Electromagnetic compatibility testing of the Spacelab engineering model is discussed. Documentation, test procedures (including data monitoring and test configuration set up) and performance assessment approach are described. Equipment was assembled into selected representative flight configurations. The physical and functional interfaces between the subsystems were demonstrated within the integration and test sequence which culminated in the flyable configuration Long Module plus one Pallet.

  6. IEEE 1988 International Symposium on Electromagnetic Compatibility, Seattle, WA, Aug. 2-4, 1988, Record

    NASA Astrophysics Data System (ADS)

    Various papers on electromagnetic compatibility are presented. Some of the optics considered include: field-to-wire coupling 1 to 18 GHz, SHF/EHF field-to-wire coupling model, numerical method for the analysis of coupling to thin wire structures, spread-spectrum system with an adaptive array for combating interference, technique to select the optimum modulation indices for suppression of undesired signals for simultaneous range and data operations, development of a MHz RF leak detector technique for aircraft harness surveillance, and performance of standard aperture shielding techniques at microwave frequncies. Also discussed are: spectrum efficiency of spread-spectrum systems, control of power supply ripple produced sidebands in microwave transistor amplifiers, an intership SATCOM versus radar electromagnetic interference prediction model, considerations in the design of a broadband E-field sensing system, unique bonding methods for spacecraft, and review of EMC practice for launch vehicle systems.

  7. Information Security due to Electromagnetic Environments

    NASA Astrophysics Data System (ADS)

    Sekiguchi, Hidenori; Seto, Shinji

    Generally, active electronic devices emit slightly unintentional electromagnetic noise. From long ago, electromagnetic emission levels have been regulated from the aspect of electromagnetic compatibility (EMC). Also, it has been known the electromagnetic emissions have been generated from the ON/OFF of signals in the device. Recently, it becomes a topic of conversation on the information security that the ON/OFF on a desired signal in the device can be reproduced or guessed by receiving the electromagnetic emission. For an example, a display image on a personal computer (PC) can be reconstructed by receiving and analyzing the electromagnetic emission. In sum, this fact makes known information leakage due to electromagnetic emission. “TEMPEST" that has been known as a code name originated in the U. S. Department of Defense is to prevent the information leakage caused by electromagnetic emissions. This paper reports the brief summary of the information security due to electromagnetic emissions from information technology equipments.

  8. Summary of the electromagnetic compatibility evaluation of the proposed satellite power system

    NASA Technical Reports Server (NTRS)

    Morrison, E. L., Jr.; Grant, W. B.; Davis, K. C.

    1980-01-01

    The effects of the proposed solar power satellite (SPS) operations on electronic equipment and systems by fundamental, harmonic, and intermodulation component emissions from the orbital station; and the fundamental, harmonic, and structural intermodulation emissions from the rectenna site were evaluated. The coupling and affects interactions affecting a wide spectrum of electronic equipment are considered. The primary EMC tasking areas are each discussed separately.

  9. Electromagnetic Noise Interference and Compatibility

    DTIC Science & Technology

    1975-11-01

    RADIO INTERFERENCE by C.Fengler 7 LES CHARGES ELECTROSTATIQUES ET LES PERTURBATIONS QU’ELLES ENTRAINENT DANS LES LIAISONS RADIOELECTRIQUES par...PAR LA TRANSMISSION DANS UN SYSTFJE INTEGRE AEROPORTE par r,.David et M.Vanneizel 31 Not available at time of priating Reference DIGITAL DATA...TRANSMISSION IN AIRCRAFT: EMC-PROBLEMS AND POSSIBLE SOLUTIONS by R.Rode 32 GENERATIONS El EFFETS DES TENSIONS PARASITES DE CONDUCTION ET DE RAVONNEMENT ENTRE

  10. Development of models simulating operation of elements of radio devices, for solving problems of ensuring electromagnetic compatibility of radio electronic means

    NASA Astrophysics Data System (ADS)

    Glotov, V. V.; Ostroumov, I. V.; Romashchenko, M. A.

    2018-05-01

    To study the effect of phase-shift signals parameters on EMC of REM, a generalized signal generation model in a radio transmitter was developed which allows obtaining digital representations of phase-shift signals, which are a continuous pulse in the time domain and on the frequency axis with different signal element envelope shapes.

  11. Comparative analyses of different variants of standard ground for automatic control systems of technical processes of oil and gas production

    NASA Astrophysics Data System (ADS)

    Gromakov, E. I.; Gazizov, A. T.; Lukin, V. P.; Chimrov, A. V.

    2017-01-01

    The paper analyses efficiency (interference resistance) of standard TT, TN, IT networks in control links of automatic control systems (ACS) of technical processes (TP) of oil and gas production. Electromagnetic compatibility (EMC) is a standard term used to describe the interference in grounding circuits. Improved EMC of ACS TP can significantly reduce risks and costs of malfunction of equipment that could have serious consequences. It has been proved that an IT network is the best type of grounds for protection of ACS TP in real life conditions. It allows reducing the interference down to the level that is stated in standards of oil and gas companies.

  12. Electromagnetic Interference/Compatibility (EMI/EMC) Control Test and Measurement Facility: User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Scully, Robert C.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the EMI/EMC Test Facility. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  13. A Real-Time Knowledge Based Expert System For Diagnostic Problem Solving

    NASA Astrophysics Data System (ADS)

    Esteva, Juan C.; Reynolds, Robert G.

    1986-03-01

    This paper is a preliminary report of a real-time expert system which is concerned with the detection and diagnosis of electrical deviations in on-board vehicle-based electrical systems. The target systems are being tested at radio frequencies to evaluate their capability to be operated at designed levels of efficiency in an electromagnetic environment. The measurement of this capability is known as ElectroMagnetic Compatibility (EMC). The Intelligent Deviation Diagnosis (IDD) system consists of two basic modules the Automatic Data Acquisition Module (ADAM) and the Diagnosis System (DS). In this paper only the diagnosis system is described.

  14. Potential Damage to Flight Hardware from MIL-STD-462 CS02 Setup

    NASA Technical Reports Server (NTRS)

    Harris, Patrick K.; Block, Nathan F.

    2003-01-01

    The MIL-STD-462 CS02 conducted susceptibility test setup includes an audio transformer, with the secondary used as an inductor, and a large capacitor. Together, these two components form an L-type low-pass filter to minimize the injected test signal input into the power source. Some flight hardware power input configurations are not compatible with this setup and break into oscillation when powered up. This, in turn, can damage flight hardware. Such an oscillation resulted in the catastrophic failure of an item tested in the Goddard Space Flight Center (GSFC) Large electromagnetic compatibility (EMC) Test Facility.

  15. Radiated EMC immunity investigation of common recognition identification platform for medical applications

    NASA Astrophysics Data System (ADS)

    Miranda, Jorge; Cabral, Jorge; Ravelo, Blaise; Wagner, Stefan; Pedersen, Christian F.; Memon, Mukhtiar; Mathiesen, Morten

    2015-01-01

    An innovative e-healthcare platform named common recognition and identification platform (CRIP) was developed and tested as part of the CareStore project. CareStore and CRIP aims at delivering accurate and safe disease management by minimising human operator errors in hospitals and care facilities. To support this, the CRIP platform features fingerprint biometrics and near field communication (NFC) for user identification; and Bluetooth communication support for a range of telemedicine medical devices adhering to the IEEE 11073 standard. The aim of this study was to evaluate the electromagnetic compatibility (EMC) immunity of the CRIP platform in order to validate it for medical application use. The first prototype of CRIP was demonstrated to operate as expected by showing the user identification function feasibility, both via NFC and biometric, and by detection of Bluetooth devices via radio frequency (RF) scanning. The NFC module works in the 13.56 MHz band and the Bluetooth module work in the 2.4 GHz band, according to the IEEE 802.15.1 standard. The standard test qualification of the CRIP was performed based on the radiated EMC immunity with respect to the EN 61000-4-3 standard. The immunity tests were conducted under industrial EMC compliance with electric field aggression, with levels up to 10 V/m in both horizontal and vertical polarisations when the test antenna and the CRIP were placed at a distance of 3 m. It was found that the CRIP device complies with the European electromagnetic (EM) radiation immunity requirements.

  16. Basic EMC (Electromagnetic Compatibility) Technology Advancement for C3 Systems. Volume 1B. Demodulation Radio Frequency Interference Effects in Operational Amplifier Circuits.

    DTIC Science & Technology

    1985-02-01

    Then it follows that H2 (fl,-f 2) (-flf Thus, the total amplitude of the intermodulation signal at fre- quency fAF is given by6 V = V +I mA2 III(fl 1-f...RFI suppression in the manner described. 229 . * . ... ..... 4 -*.-., ,e ’ - ."..~ REFERENCES 1. G. Kaplan , "Computer Aided Design," IEEE Spectrum, Vol

  17. Numerical analysis of electromagnetic cascades in emulsion chambers

    NASA Technical Reports Server (NTRS)

    Plyasheshnikov, A. V.; Vorobyev, K. V.

    1985-01-01

    A new calculational scheme of the Monte Carlo method assigned for the investigation of the development of high and extremely high energy electromagnetic cascades (EMC) in the matter was elaborated. The scheme was applied to the analysis of angular and radial distributions of EMC electrons in the atmosphere. By means of this scheme the EMC development in dense medium is investigated and some preliminary data are presented on the behavior of EMC in emulsion chambers. The results of more detailed theoretical analysis of the EMC development in emulsion chambers are discussed.

  18. Measurement technology of RF interference current in high current system

    NASA Astrophysics Data System (ADS)

    Zhao, Zhihua; Li, Jianxuan; Zhang, Xiangming; Zhang, Lei

    2018-06-01

    Current probe is a detection method commonly used in electromagnetic compatibility. With the development of power electronics technology, the power level of power conversion devices is constantly increasing, and the power current of the electric energy conversion device in the electromagnetic launch system can reach 10kA. Current probe conventionally used in EMC (electromagnetic compatibility) detection cannot meet the test requirements on high current system due to the magnetic saturation problem. The conventional high current sensor is also not suitable for the RF (Radio Frequency) interference current measurement in high current power device due to the high noise level in the output of active amplifier. In this paper, a passive flexible current probe based on Rogowski coil and matching resistance is proposed that can withstand high current and has low noise level, to solve the measurement problems of interference current in high current power converter. And both differential mode and common mode current detection can be easily carried out with the proposed probe because of the probe's flexible structure.

  19. Penetration of High Intensity Radiated Fields (HIRF) Into General Aviation Aircraft

    NASA Technical Reports Server (NTRS)

    Balanis, Constantine A.; Birtcher, Craig R.; Georgakopoulos, Stavros V.; Panaretos, Anastasios H.

    2004-01-01

    The ability to design and achieve electromagnetic compatibility is becoming more challenging with the rapid development of new electronic products and technologies. The importance of electromagnetic interference (EMI) and electromagnetic compatibility (EMC) issues stems from the fact that the ambient electromagnetic environment has become very hostile; that is, it increases both in density and intensity, while the current trend in technology suggests the number of electronic devices increases in homes, businesses, factories, and transportation vehicles. Furthermore, the operating frequency of products coming into the market continuously increases. While cell phone technology has exceeded 1 GHz and Bluetooth operates at 2.4 GHz, products involving satellite communications operate near 10 GHz and automobile radar systems involve frequencies above 40 GHz. The concern about higher frequencies is that they correspond to smaller wavelengths, therefore electromagnetic waves are able to penetrate equipment enclosure through apertures or even small cracks more easily. In addition, electronic circuits have become small in size, and they are usually placed on motherboards or housed in boxes in very close proximity. Cosite interference and coupling in all electrical and electronic circuit assemblies are two essential issues that have to be examined in every design.

  20. Electromagnetic Compatibility (EMC) Requirements for Military and Commercial Equipment

    DTIC Science & Technology

    2009-09-01

    Commercial off-the shelf (COTS) use also provides access to what has become a much larger industrial base. With these goals in mind, the Secretary of...Band (110 – 300 GHz) 10–1 mm Microwave data links, radio astronomy , amateur radio, remote sensing, advanced weapons systems 12 Radiated EMI...to what has become a much larger industrial base. With these goals in mind, the Secretary of Defense issued a directive in June 1994 requiring the

  1. Active System for Electromagnetic Perturbation Monitoring in Vehicles

    NASA Astrophysics Data System (ADS)

    Matoi, Adrian Marian; Helerea, Elena

    Nowadays electromagnetic environment is rapidly expanding in frequency domain and wireless services extend in terms of covered area. European electromagnetic compatibility regulations refer to limit values regarding emissions, as well as procedures for determining susceptibility of the vehicle. Approval procedure for a series of cars is based on determining emissions/immunity level for a few vehicles picked randomly from the entire series, supposing that entire vehicle series is compliant. During immunity assessment, the vehicle is not subjected to real perturbation sources, but exposed to electric/magnetic fields generated by laboratory equipment. Since current approach takes into account only partially real situation regarding perturbation sources, this paper proposes an active system for determining electromagnetic parameters of vehicle's environment, that implements a logical diagram for measurement, satisfying the imposed requirements. This new and original solution is useful for EMC assessment of hybrid and electrical vehicles.

  2. Analysis of Waves in Space Plasma (WISP) near field simulation and experiment

    NASA Technical Reports Server (NTRS)

    Richie, James E.

    1992-01-01

    The WISP payload scheduler for a 1995 space transportation system (shuttle flight) will include a large power transmitter on board at a wide range of frequencies. The levels of electromagnetic interference/electromagnetic compatibility (EMI/EMC) must be addressed to insure the safety of the shuttle crew. This report is concerned with the simulation and experimental verification of EMI/EMC for the WISP payload in the shuttle cargo bay. The simulations have been carried out using the method of moments for both thin wires and patches to stimulate closed solids. Data obtained from simulation is compared with experimental results. An investigation of the accuracy of the modeling approach is also included. The report begins with a description of the WISP experiment. A description of the model used to simulate the cargo bay follows. The results of the simulation are compared to experimental data on the input impedance of the WISP antenna with the cargo bay present. A discussion of the methods used to verify the accuracy of the model is shown to illustrate appropriate methods for obtaining this information. Finally, suggestions for future work are provided.

  3. EMC design for actuators in the FAST reflector

    NASA Astrophysics Data System (ADS)

    Zhang, Hai-Yan; Wu, Ming-Chang; Yue, You-Ling; Gan, Heng-Qian; Hu, Hao; Huang, Shi-Jie

    2018-04-01

    An active reflector is one of the three main innovations incorporated in the Five-hundred-meter Aperture Spherical radio Telescope (FAST). The deformation of such a huge spherically shaped reflector into different transient parabolic shapes is achieved by using 2225 hydraulic actuators which change the position of the 2225 nodes through the connected down tied cables. For each different tracking process of the telescope, more than 1/3 of these 2225 actuators must be in operation to tune the parabolic aperture accurately and meet the surface error restriction. This means that some of these actuators are inevitably located within the main beam of the receiver, and Electromagnetic Interference (EMI) from the actuators must be mitigated to ensure the scientific output of the telescope. Based on the threshold level of interference detrimental to radio astronomy described in ITU-R Recommendation RA.769 and EMI measurements, the shielding efficiency (SE) requirement for each actuator is set to be 80 dB in the frequency range from 70 MHz to 3 GHz. Therefore, Electromagnetic Compatibility (EMC) was taken into account in the actuator design by measures such as power line filters, optical fibers, shielding enclosures and other structural measures. In 2015, all the actuators had been installed at the FAST site. Till now, no apparent EMI from the actuators has been detected by the receiver, which demonstrates the effectiveness of these EMC measures.

  4. Analysis of waveguides containing EMCs (electromagnetic conductors) or PEMCs (perfect electromagnetic conductors)

    NASA Astrophysics Data System (ADS)

    Prudêncio, Filipa R.; Matos, Sérgio A.; Paiva, Carlos R.

    2014-11-01

    The concept of a perfect electromagnetic conductor (PEMC) was introduced to generalize and unify two well-known and apparently disjoint concepts in electromagnetics: the perfect electric conductor (PEC) and the perfect magnetic conductor (PMC). Although the PEMC has proven a fertile tool in electromagnetic analyses dealing with new and complex boundaries, its corresponding definition as a medium has, nevertheless, raised several problems. In fact, according to its initial 3D definition, the PEMC cannot be considered a unique and well-defined medium: it leads to extraneous fields without physical meaning. By using a previously published generalization of a PEMC that regards this concept both as a boundary and as a medium - which was dubbed an MIM (Minkowskian isotropic medium) and acts, in practice, as an actual electromagnetic conductor (EMC) - it is herein presented a straightforward analysis of waveguides containing PEMCs that readily and systematically follows from the general framework of waveguides containing EMCs.

  5. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Test Report, Electromagnetic Interference (EMI)/Electromagnetic Radiation(EMR) and Electromagnetic Capability (EMC) for the EOS/AMSU-A1

    NASA Technical Reports Server (NTRS)

    Paliwoda, L.

    1998-01-01

    This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Earth Observing System (EOS) Project, assembly part number 1356008-1, serial number 202, Electromagnetic Interference (EMI) and Electromagnetic Susceptibility (EMC) qualification test. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/8B, dated 10 September 1998. Aerojet intends that the presentation and submittal of this document, prepared in accordance with the objectives established by the aforementioned Test Plan/Procedure, document number AE-26151/8B, will satisfy the data requirement with respect to the AMSU-A/EOS instrument operational compliance of the EMI/EMC test requirement. Test for the AMSU-A/EOS instrument have been completed and all the requirements per General Interface Requirement Document (GIRD), GSFC 422-11-12-01, for EOS Common Spacecraft/Instruments, paragraph 10.11, were met with the exceptions of the test methods CE03, RE01, and RE02, as described in this document.

  6. Characteristics of the wire biconical antenna used for EMC measurements

    NASA Astrophysics Data System (ADS)

    Austin, Brian A.; Fourie, Andre P. C.

    1991-08-01

    The characteristics of a wire biconical antenna that determine its antenna factor were computed by using the method of moments code NEC-2. A fairly extensive validation exercise was conducted from which a suitable computer model was derived. The input impedance, gain, and radiation patterns of the antenna were computed for special cases where the biconical antenna is used above a conducting ground plane for open-field EMC (electromagnetic compatibility) testing. The effects of height above the ground plane and polarization of the antenna on these parameters were found and the antenna factor was corrected for them. The current distribution along the antenna elements was also examined, and it was found that significant pattern distortion can occur at some frequencies when a horizontal wire biconical antenna is used close to the ground. These results will allow this broadband antenna to be used with confidence in applications where previously only resonant dipoles were specified.

  7. Definition and test of the electromagnetic immunity of UAS for first responders

    NASA Astrophysics Data System (ADS)

    Adami, C.; Chmel, S.; Jöster, M.; Pusch, T.; Suhrke, M.

    2015-11-01

    Recent technological developments considerably lowered the barrier for unmanned aerial systems (UAS) to be employed in a variety of usage scenarios, comprising live video transmission from otherwise inaccessible vantage points. As an example, in the French-German ANCHORS project several UAS guided by swarm intelligence provide aerial views and environmental data of a disaster site while deploying an ad-hoc communication network for first responders. Since being able to operate in harsh environmental conditions is a key feature, the immunity of the UAS against radio frequency (RF) exposure has been studied. Conventional Electromagnetic Compatibility (EMC) applied to commercial and industrial electronics is not sufficient since UAS are airborne and can as such move beyond the bounds within which RF exposure is usually limited by regulatory measures. Therefore, the EMC requirements have been complemented by a set of specific RF test frequencies and parameters where strong sources are expected to interfere in the example project test case of an inland port environment. While no essential malfunctions could be observed up to field strengths of 30 V m-1, a sophisticated, more exhaustive approach for testing against potential sources of interference in key scenarios of UAS usage should be derived from our present findings.

  8. Basic EMC (Electromagnetic Compatibility) Technology Advancement for C3 Systems, Macromodeling of Digital Circuits. Volume 2B.

    DTIC Science & Technology

    1984-04-01

    dependent source to multiply a ramp by a unit sinusoid. Using this method, data could be extracted from a single run to show the magnitude of the...IHPUT VOLTAGE SOURCES VAC 1 0 0V VAl 2 0 0V VA2 3 0 0V VA3 4 0 PULSE(OV 3V ONSD 2NSR 2NSF 198NSPW) VB0 5 0 OV VB1 6 0 OV VB2 7 0 CV VB3 8 0 PULSE

  9. Basic EMC (Electromagnetic compatibility) technology advancement for C3 (Command, control, and communications) systems. Volume 6

    NASA Astrophysics Data System (ADS)

    Weiner, D.; Paul, C. R.; Whalen, J.

    1985-04-01

    This research effort was devoted to eliminating some of the basic technological gaps in the two important areas of: (1) electromagnetic effects (EM) on microelectronic circuits and (2) EM coupling and testing. The results are presented in fourteen reports which have been organized into six volumes. The reports are briefly summarized in this volume. In addition, an experiment is described which was performed to demonstrate the feasibility of applying several of the results to a problem involving electromagnetic interference. Specifically, experimental results are provided for the randomness associated with: (1) crosstalk in cable harnesses and (2) demodulation of amplitude modulated (AM) signals in operational amplifiers. These results are combined to predict candidate probability density functions (pdf's) for the amplitude of an AM interfering signal required to turn on a light emitting diode. The candidate pdf's are shown to be statistically consistent with measured data.

  10. Electromagnetic Compatibility of Devices on Hybrid Electromagnetic Components

    NASA Astrophysics Data System (ADS)

    Konesev, S. G.; Khazieva, R. T.; Kirillov, R. V.; Gainutdinov, I. Z.; Kondratyev, E. Y.

    2018-01-01

    There is a general tendency to reduce the weight and dimensions, the consumption of conductive and electrical insulating materials, increase the reliability and energy efficiency of electrical devices. In recent years, designers have been actively developing devices based on hybrid electromagnetic components (HEMC) such as inductive-capacitive converters (ICC), voltages pulse generators (VPG), secondary power supplies (SPS), capacitive storage devices (CSD), induction heating systems (IHS). Sources of power supplies of similar electrical devices contain, as a rule, links of increased frequency and function in key (pulse) modes, which leads to an increase in electromagnetic interference (EMI). Nonlinear and periodic (impulse) loads, non-sinusoidal (pulsation) of the electromotive force and nonlinearity of the internal parameters of the source and input circuits of consumers distort the shape of the input voltage lead to an increase in thermal losses from the higher harmonic currents, aging of the insulation, increase in the weight of the power supply filter units, resonance at higher harmonics. The most important task is to analyze the operation of electrotechnical devices based on HEMC from the point of view of creating EMIs and assessing their electromagnetic compatibility (EMC) with power supply systems (PSS). The article presents the results of research on the operation of an IHS, the operation principle of a secondary power supply source of which is based on the operation of a half-bridge autonomous inverter, the switching circuit of which is made in the form of a HEMC, called the «multifunctional integrated electromagnetic component»" (MIEC).

  11. Hardware Demonstration: Radiated Emissions as a Function of Common Mode Current

    NASA Technical Reports Server (NTRS)

    Mc Closkey, John; Roberts, Jen

    2016-01-01

    This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.

  12. 1998 Conference on Precision Electromagnetic Measurements Digest. Proceedings.

    NASA Astrophysics Data System (ADS)

    Nelson, T. L.

    The following topics were dealt with: fundamental constants; caesium standards; AC-DC transfer; impedance measurement; length measurement; units; statistics; cryogenic resonators; time transfer; QED; resistance scaling and bridges; mass measurement; atomic fountains and clocks; single electron transport; Newtonian constant of gravitation; stabilised lasers and frequency measurements; cryogenic current comparators; optical frequency standards; high voltage devices and systems; international compatibility; magnetic measurement; precision power measurement; high resolution spectroscopy; DC transport standards; waveform acquisition and analysis; ion trap standards; optical metrology; quantised Hall effect; Josephson array comparisons; signal generation and measurement; Avogadro constant; microwave networks; wideband power standards; antennas, fields and EMC; quantum-based standards.

  13. Design Guidelines for Shielding Effectiveness, Current Carrying Capability, and the Enhancement of Conductivity of Composite Materials

    NASA Technical Reports Server (NTRS)

    Evans, R. W.

    1997-01-01

    These guidelines address the electrical properties of composite materials which may have an effect on electromagnetic compatibility (EMC). The main topics of the guidelines include the electrical shielding, fault current return, and lightning protection capabilities of graphite reinforced polymers, since they are somewhat conductive but may require enhancement to be adequate for EMC purposes. Shielding effectiveness depends heavily upon the conductivity of the material. Graphite epoxy can provide useful shielding against RF signals, but it is approximately 1,000 times more resistive than good conductive metals. The reduced shielding effectiveness is significant but is still useful in many cases. The primary concern is with gaps and seams in the material just as it is with metal. Current carrying capability of graphite epoxy is adequate for dissipation static charges, but fault currents through graphite epoxy may cause fire at the shorting contact and at joints. The effect of lightning on selected graphite epoxy material and mating surfaces is described, and protection methods are reviewed.

  14. Preparation and characterization of TiO2 coated Fe nanofibers for electromagnetic wave absorber.

    PubMed

    Jang, Dae-Hwan; Song, Hanbok; Lee, Young-In; Lee, Kun-Jae; Kim, Ki Hyeon; Oh, Sung-Tag; Lee, Sang-Kwan; Choa, Yong-Ho

    2011-01-01

    Recently, electromagnetic interference (EMI) and electromagnetic compatibility (EMC) have become serious problems due to the growth of electronic device and next generation telecommunication. It is necessary to develop new electromagnetic wave absorbing material to overcome the limitation of electromagnetic wave shielding materials. The EMI attenuation is normally related to magnetic loss and dielectric loss. Therefore, magnetic material coating dielectric materials are required in this reason. In this study, TiO2 coated Fe nanofibers were prepared to improve their properties for electromagnetic wave absorption. Poly(vinylpyrrolidone) (PVP) and Iron (III) nitrate nonahydrate (Fe(NO3)3 x 9H2O) were used as starting materials for the synthesis of Fe oxide nanofibers. Fe oxide nanofibers were prepared by electrospinning in an electric field and heat treatment. TiO2 layer was coated on the surface of Fe oxide nanofibers using sol-gel process. After the reduction of TiO2 coated Fe oxide nanofibers, Fe nanofibers with a TiO2 coating layer of about 10 nm were successfully obtained. The morphology and structure of fibers were characterized by SEM, TEM, and XRD. In addition, the absorption properties of TiO2 coated Fe nanofibers were measured by network analyzer.

  15. FDTD simulation of field performance in reverberation chamber excited by two excitation antennas

    NASA Astrophysics Data System (ADS)

    Wang, Song; Wu, Zhan-cheng; Cui, Yao-zhong

    2013-03-01

    The excitation source is one of the critical items that determine the electromagnetic fields in a reverberation chamber (RC). In order to optimize the electromagnetic fields performance, a new method of exciting RC with two antennas is proposed based on theoretical analysis. The full 3D simulation of RC is carried out by the finite difference time domain (FDTD) method on two excitation conditions of one antenna and two antennas. The broadband response of RC is obtained by fast Fourier transformation (FFT) after only one simulation. Numerical data show that the field uniformity in the test space is improved on the condition of two transmitting antennas while the normalized electric fields decreased slightly compared to the one antenna condition. It is straightforward to recognize that two antennas excitation can reduce the demands on power amplifier as the total input power is split among the two antennas, and consequently the cost of electromagnetic compatibility (EMC) test in large-scale RC can be reduced.

  16. Basic EMC (Electromagnetic compatibility) technology advancement for C3 systems. Volume 4D: Modeling crosstalk in balanced twisted pairs

    NASA Astrophysics Data System (ADS)

    Koopman, D. A.; Paul, C. R.

    1984-08-01

    Electrical devices (computers, radar systems, communication radios, etc.) are interconnected by wires on most present systems. Electromagnetic fields produced by the excitation of these wires will cause unintentional coupling of signals onto nearby wires. This undesired electromagnetic coupling is termed crosstalk. It is important to be able to determine whether these crosstalk signals will cause the devices at the ends of the wires to malfunction. Wires are often grouped together in cable bundles or harnesses. The close proximity of wires in these bundles enhances the possibility that the crosstalk levels will be sufficiently large to cause malfunctions. The ability to predict crosstalk levels and the means to control crosstalk when it causes a problem are important to optimum system design. It interference of this type is allowed to surface during final system tests, a costly and time consuming retrofit of the wiring or the addition of filters and other interference control measures may be required.

  17. Electromagnetic code for naval applications

    NASA Astrophysics Data System (ADS)

    Crescimbeni, F.; Bessi, F.; Chiti, S.

    1988-12-01

    The use of an increasing number of electronic apparatus became vital to meet the high performance required for military Navy applications. Thus the number of antennas to be mounted on shipboard greatly increased. As a consequence of the high antenna density, of the complexity of the shipboard environment and of the powers used for communication and radar systems, the EMC (Electro-Magnetic Compatibility) problem is playing a leading role in the design of the topside of a ship. The Italian Navy has acquired a numerical code for the antenna siting and design. This code, together with experimental data measured at the Italian Navy test range facility, allows for the evaluation of optimal sitings for antenna systems on shipboard, and the prediction of their performances in the actual environment. The structure of this code, named Programma Elettromagnetico per Applicazioni Navali, (Electromagnetic Code for Naval Applications) is discussed, together with its capabilities and applications. Also the results obtained in some examples are presented and compared with the measurements.

  18. Adhoc electromagnetic compatibility testing of non-implantable medical devices and radio frequency identification

    PubMed Central

    2013-01-01

    Background The use of radiofrequency identification (RFID) in healthcare is increasing and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have documented that RFID can interfere with medical devices. The majority of past studies have concentrated on implantable medical devices such as implantable pacemakers and implantable cardioverter defibrillators (ICDs). This study examined EMC between RFID systems and non-implantable medical devices. Methods Medical devices were exposed to 19 different RFID readers and one RFID active tag. The RFID systems used covered 5 different frequency bands: 125–134 kHz (low frequency (LF)); 13.56 MHz (high frequency (HF)); 433 MHz; 915 MHz (ultra high frequency (UHF])) and 2.4 GHz. We tested three syringe pumps, three infusion pumps, four automatic external defibrillators (AEDs), and one ventilator. The testing procedure is modified from American National Standards Institute (ANSI) C63.18, Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Radiated Electromagnetic Immunity of Medical Devices to Specific Radio-Frequency Transmitters. Results For syringe pumps, we observed electromagnetic interference (EMI) during 13 of 60 experiments (22%) at a maximum distance of 59 cm. For infusion pumps, we observed EMI during 10 of 60 experiments (17%) at a maximum distance of 136 cm. For AEDs, we observed EMI during 18 of 75 experiments (24%) at a maximum distance of 51 cm. The majority of the EMI observed was classified as probably clinically significant or left the device inoperable. No EMI was observed for all medical devices tested during exposure to 433 MHz (two readers, one active tag) or 2.4 GHz RFID (two readers). Conclusion Testing confirms that RFID has the ability to interfere with critical medical equipment. Hospital staff should be aware of the potential for medical device EMI caused by RFID systems and should be encouraged to perform on-site RF immunity tests prior to RFID system deployment or prior to placing new medical devices in an RFID environment. The methods presented in this paper are time-consuming and burdensome and suggest the need for standard test methods for assessing the immunity of medical devices to RFID systems. PMID:23845013

  19. Adhoc electromagnetic compatibility testing of non-implantable medical devices and radio frequency identification.

    PubMed

    Seidman, Seth J; Guag, Joshua W

    2013-07-11

    The use of radiofrequency identification (RFID) in healthcare is increasing and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have documented that RFID can interfere with medical devices. The majority of past studies have concentrated on implantable medical devices such as implantable pacemakers and implantable cardioverter defibrillators (ICDs). This study examined EMC between RFID systems and non-implantable medical devices. Medical devices were exposed to 19 different RFID readers and one RFID active tag. The RFID systems used covered 5 different frequency bands: 125-134 kHz (low frequency (LF)); 13.56 MHz (high frequency (HF)); 433 MHz; 915 MHz (ultra high frequency (UHF])) and 2.4 GHz. We tested three syringe pumps, three infusion pumps, four automatic external defibrillators (AEDs), and one ventilator. The testing procedure is modified from American National Standards Institute (ANSI) C63.18, Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Radiated Electromagnetic Immunity of Medical Devices to Specific Radio-Frequency Transmitters. For syringe pumps, we observed electromagnetic interference (EMI) during 13 of 60 experiments (22%) at a maximum distance of 59 cm. For infusion pumps, we observed EMI during 10 of 60 experiments (17%) at a maximum distance of 136 cm. For AEDs, we observed EMI during 18 of 75 experiments (24%) at a maximum distance of 51 cm. The majority of the EMI observed was classified as probably clinically significant or left the device inoperable. No EMI was observed for all medical devices tested during exposure to 433 MHz (two readers, one active tag) or 2.4 GHz RFID (two readers). Testing confirms that RFID has the ability to interfere with critical medical equipment. Hospital staff should be aware of the potential for medical device EMI caused by RFID systems and should be encouraged to perform on-site RF immunity tests prior to RFID system deployment or prior to placing new medical devices in an RFID environment. The methods presented in this paper are time-consuming and burdensome and suggest the need for standard test methods for assessing the immunity of medical devices to RFID systems.

  20. Electromagnetic compatibility of implantable neurostimulators to RFID emitters

    PubMed Central

    2011-01-01

    Background The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. Methods Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz Results The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. Conclusions The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters. PMID:21658266

  1. Electromagnetic compatibility of implantable neurostimulators to RFID emitters.

    PubMed

    Pantchenko, Oxana S; Seidman, Seth J; Guag, Joshua W; Witters, Donald M; Sponberg, Curt L

    2011-06-09

    The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz. The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  2. Assessment of risks of EMI for personal medical electronic devices (PMEDs) from emissions of millimeter-wave security screening systems

    NASA Astrophysics Data System (ADS)

    Witters, Donald; Bassen, Howard; Guag, Joshua; Addissie, Bisrat; LaSorte, Nickolas; Rafai, Hazem

    2013-06-01

    This paper describes research and testing of a representative group of high priority body worn and implantable personal medical electronic devices (PMEDs) for exposure to millimeter wave (MMW) advanced imaging technology (AIT) security systems used at airports. The sample PMEDs included in this study were implantable cardiac pacemakers, ICDs, neurostimulators and insulin pumps. These PMEDs are designed and tested for susceptibility to electromagnetic interference (EMI) under the present standards for medical device electromagnetic compatibility (EMC). However, the present standards for medical equipment do not address exposure to the much higher frequency fields that are emitted by MMW security systems. Initial AIT emissions measurements were performed to assess the PMED and passenger exposures. Testing protocols were developed and testing methods were tailored to the type of PMED. In addition, a novel exposure simulation system was developed to allow controlled EMC testing without the need of the MMW AIT system. Methodology, test results, and analysis are presented, along with an assessment of the human exposure and risks for PMED users. The results on this study reveal no effects on the medical devices from the exposure to the MMW security system. Furthermore, the human exposure measurements and analysis showed levels well below applicable standard, and the risks for PMED users and others we assessed to be very low. These findings apply to the types of PMEDs used in the study though these findings might suggest that the risks for other, similar PMEDs would likely be similar.

  3. EMC Aspects of Turbulence Heating ObserveR (THOR) Spacecraft

    NASA Astrophysics Data System (ADS)

    Soucek, J.; Ahlen, L.; Bale, S.; Bonnell, J.; Boudin, N.; Brienza, D.; Carr, C.; Cipriani, F.; Escoubet, C. P.; Fazakerley, A.; Gehler, M.; Genot, V.; Hilgers, A.; Hanock, B.; Jannet, G.; Junge, A.; Khotyaintsev, Y.; De Keyser, J.; Kucharek, H.; Lan, R.; Lavraud, B.; Leblanc, F.; Magnes, W.; Mansour, M.; Marcucci, M. F.; Nakamura, R.; Nemecek, Z.; Owen, C.; Phal, Y.; Retino, A.; Rodgers, D.; Safrankova, J.; Sahraoui, F.; Vainio, R.; Wimmer-Schweingruber, R.; Steinhagen, J.; Vaivads, A.; Wielders, A.; Zaslavsky, A.

    2016-05-01

    Turbulence Heating ObserveR (THOR) is a spacecraft mission dedicated to the study of plasma turbulence in near-Earth space. The mission is currently under study for implementation as a part of ESA Cosmic Vision program. THOR will involve a single spinning spacecraft equipped with state of the art instruments capable of sensitive measurements of electromagnetic fields and plasma particles. The sensitive electric and magnetic field measurements require that the spacecraft- generated emissions are restricted and strictly controlled; therefore a comprehensive EMC program has been put in place already during the study phase. The THOR study team and a dedicated EMC working group are formulating the mission EMC requirements already in the earliest phase of the project to avoid later delays and cost increases related to EMC. This article introduces the THOR mission and reviews the current state of its EMC requirements.

  4. Performance of thin-film ferroelectric capacitors for EMC decoupling.

    PubMed

    Li, Huadong; Subramanyam, Guru

    2008-12-01

    This paper studied the effects of thin-film ferroelectrics as decoupling capacitors for electromagnetic compatibility applications. The impedance and insertion loss of PZT capacitors were measured and compared with the results from commercial off-the-shelf capacitors. An equivalent circuit model was extracted from the experimental results, and a considerable series resistance was found to exist in ferroelectric capacitors. This resistance gives rise to the observed performance difference around series resonance between ferroelectric PZT capacitors and normal capacitors. Measurements on paraelectric (Ba,Sr)TiO(3)-based integrated varactors do not show this significant resistance. Some analyses were made to investigate the mechanisms, and it was found that it can be due to the hysteresis in the ferroelectric thin films.

  5. Absorber for microwave investigation in the open space

    NASA Astrophysics Data System (ADS)

    Kubacki, Roman; Smólski, Bogusław; Głuszewski, Wojciech; Przesmycki, Rafał; Rudyk, Karol

    2017-04-01

    In some circumstances there is a need to realize the Electromagnetic Compatibility (EMC) investigation not in the specialized anechoic chamber but in the open space. Typical absorbers used in anechoic chamber to reduce the reflected rays from walls and floor, such as ferrite plates and graphite cones, are not suitable in the open space. In the work the investigation of the flexible absorbing material intended to the liquidation of the radiation reflected from the ground has been presented. As an absorbing material the metallic-glass with graphite was elaborated. This material was additionally exposed to the ionizing radiation in the dose of 100 kGy in the radioactive gamma source. The permittivity, permeability as well as the shielding properties have been analyzed.

  6. Electromagnetic Compatibility Testing Studies

    NASA Technical Reports Server (NTRS)

    Trost, Thomas F.; Mitra, Atindra K.

    1996-01-01

    This report discusses the results on analytical models and measurement and simulation of statistical properties from a study of microwave reverberation (mode-stirred) chambers performed at Texas Tech University. Two analytical models of power transfer vs. frequency in a chamber, one for antenna-to-antenna transfer and the other for antenna to D-dot sensor, were experimentally validated in our chamber. Two examples are presented of the measurement and calculation of chamber Q, one for each of the models. Measurements of EM power density validate a theoretical probability distribution on and away from the chamber walls and also yield a distribution with larger standard deviation at frequencies below the range of validity of the theory. Measurements of EM power density at pairs of points which validate a theoretical spatial correlation function on the chamber walls and also yield a correlation function with larger correlation length, R(sub corr), at frequencies below the range of validity of the theory. A numerical simulation, employing a rectangular cavity with a moving wall shows agreement with the measurements. The determination that the lowest frequency at which the theoretical spatial correlation function is valid in our chamber is considerably higher than the lowest frequency recommended by current guidelines for utilizing reverberation chambers in EMC testing. Two suggestions have been made for future studies related to EMC testing.

  7. Space processing applications payload equipment study. Volume 2B: Payload interface analysis (power/thermal/electromagnetic compatibility)

    NASA Technical Reports Server (NTRS)

    Hammel, R. L. (Editor); Smith, A. G. (Editor)

    1974-01-01

    As a part of the task of performing preliminary engineering analysis of modular payload subelement/host vehicle interfaces, a subsystem interface analysis was performed to establish the integrity of the modular approach to the equipment design and integration. Salient areas that were selected for analysis were power and power conditioning, heat rejection and electromagnetic capability (EMC). The equipment and load profiles for twelve representative experiments were identified. Two of the twelve experiments were chosen as being representative of the group and have been described in greater detail to illustrate the evaluations used in the analysis. The shuttle orbiter will provide electrical power from its three fuel cells in support of the orbiter and the Spacelab operations. One of the three shuttle orbiter fuel cells will be dedicated to the Spacelab electrical power requirements during normal shuttle operation. This power supplies the Spacelab subsystems and the excess will be available to the payload. The current Spacelab sybsystem requirements result in a payload allocation of 4.0 to 4.8 kW average (24 hour/day) and 9.0 kW peak for 15 minutes.

  8. EMC tests on the RITA Ion Propulsion Assembly for the ARTEMIS satellite

    NASA Astrophysics Data System (ADS)

    Mueller, H.; Kukies, R.; Bassner, H.

    1992-07-01

    Objectives and results of EMC tests performed on the RITA Ion Propulsion Assembly to demonstrate its compatibility with the requirements of ARTEMIS are discussed. The tested configuration included the RIT 10 thruster, neutralizer, RF generator, power supply and control unit, and electrical ground support equipment. Test results show that the RIT 10 thruster fulfils the EMC requirements for radiated emission in the critical frequency ranges (L/S/KU bands). The emitted E- and H-fields are not expected to disturb the satellite electronics, and no special shielding or other measures to protect the antennas are needed.

  9. Evaluation of Electromagnetic Fields in a Hospital for Safe Use of Electronic Medical Equipment.

    PubMed

    Ishida, Kai; Fujioka, Tomomi; Endo, Tetsuo; Hosokawa, Ren; Fujisaki, Tetsushi; Yoshino, Ryoji; Hirose, Minoru

    2016-03-01

    Establishment of electromagnetic compatibility is important in use of electronic medical equipment in hospitals. To evaluate the electromagnetic environment, the electric field intensity induced by electromagnetic radiation in broadcasting spectra coming from outside the hospital was measured in a new hospital building before any patients visited the hospital and 6 months after the opening of the hospital. Various incoming radio waves were detected on the upper floors, with no significant difference in measured levels before and after opening of the hospital. There were no cellphone terminal signals before the hospital opened, but these signals were strongly detected at 6 months thereafter. Cellphone base stations signals were strongly detected on the upper floors, but there were no signals at most locations in the basement and in the center of the building on the lower floors. A maximum electrical intensity of 0.28 V/m from cellphone base stations (2.1 GHz) was detected at the south end of the 2nd floor before the hospital opened. This value is lower than the EMC marginal value for general electronic medical equipment specified in IEC 60601-1-2 (3 V/m). Therefore, electromagnetic interference with electronic medical equipment is unlikely in this situation. However, cellphone terminal signals were frequently detected in non-base station signal areas. This is a concern, and understanding signal strength from cellphone base stations at a hospital is important for promotion of greater safety.

  10. Radiated Emissions from a Remote-Controlled Airplane-Measured in a Reverberation Chamber

    NASA Technical Reports Server (NTRS)

    Ely, Jay J.; Koppen, Sandra V.; Nguyen, Truong X.; Dudley, Kenneth L.; Szatkowski, George N.; Quach, Cuong C.; Vazquez, Sixto L.; Mielnik, John J.; Hogge, Edward F.; Hill, Boyd L.; hide

    2011-01-01

    A full-vehicle, subscale all-electric model airplane was tested for radiated emissions, using a reverberation chamber. The mission of the NASA model airplane is to test in-flight airframe damage diagnosis and battery prognosis algorithms, and provide experimental data for other aviation safety research. Subscale model airplanes are economical experimental tools, but assembling their systems from hobbyist and low-cost components may lead to unforseen electromagnetic compatibility problems. This report provides a guide for accommodating the on-board radio systems, so that all model airplane systems may be operated during radiated emission testing. Radiated emission data are provided for on-board systems being operated separately and together, so that potential interferors can be isolated and mitigated. The report concludes with recommendations for EMI/EMC best practices for subscale model airplanes and airships used for research.

  11. Automating the deconfliction of jamming and spectrum management

    NASA Astrophysics Data System (ADS)

    Segner, Samuel M.

    1988-12-01

    Powerful airborne and ground based jammers are being fielded by all services and nations as part of their intelligence/electronic warfare (I/EW) combat capability. For their survivability, these I/EW systems operate far from the FLOT; this creates rather large denial areas to friendly forces when they jam. Manual coordination between IE/W managers and spectrum managers is not practical to take on targets of opportunities or track the intended enemy victims when these victims counter by frequency maneuvers. Two possible architectures, one centralized, the other decentralized, are explored as is the applicability of the electromagnetic compatibility (EMC) software developed for the U.S. Army Automatic Tactical Frequency Engineering System (ATFES) pilot program. The proposed approach is to apply the principles of the Joint Commanders EW Staff (JCEWS). The initial simplified software to demonstrate the computer aided coordination at VHF is explained.

  12. Galileo environmental test and analysis program summary

    NASA Technical Reports Server (NTRS)

    Hoffman, A. R.

    1991-01-01

    This paper presents an overview of the Galileo Project's environmental test and analysis program during the spacecraft development phase - October 1978 through launch in October 1989. After describing the top-level objectives of the program, summaries of-the approach, requirements, and margins are provided. Examples of assembly- and system-level test results are given for both the pre-1986 (direct mission) testing and the post-1986 (Venus-Earth-Earth gravity assist mission) testing, including dynamic, thermal, electromagnetic compatibility (EMC), and magnetic. The approaches and results for verifying by analysis that the requirements of certain environments (e.g., radiation, micrometeoroids, and single event upsets) are satisfied are presented. The environmental program implemented on Galileo satisfied the spirit and intent of the requirements imposed by the Project during the spacecraft's development. The lessons learned from the Galileo environmental program are discussed in this paper.

  13. Instrumentation and test methods of an automated radiated susceptibility system

    NASA Astrophysics Data System (ADS)

    Howard, M. W.; Deere, J.

    1983-09-01

    The instrumentation and test methods of an automated electromagnetic compatibility (EMC) system for performing radiated susceptibility tests from 14 kHz to 1000 MHz is described. Particular emphasis is given to the effectiveness of the system in the evaluation of electronic circuits for susceptibility to RF radiation. The system consists of a centralized data acquisition/control unit which interfaces with the equipment under test (EUT), the RF isolated field probes, and RF amplifier ALC output; four broadband linear RF amplifiers; and a frequency synthesizer with drive level increments in steps of 0.1 dB. Centralized control of the susceptibility test system is provided by a desktop computer. It is found that the system can reduce the execution time of RF susceptibility tests by as much as 70 percent. A block diagram of the system is provided.

  14. Current status and performance of the BESIII electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Fang, Jian; Wang, Zhigang

    2012-12-01

    The design and construction of the BESIII electromagnetic calorimeter is introduced briefly. Radiation dose of CsI(Tl) crystals is monitored and history graph of integral dose of crystals is showed. LED-fiber system is used for monitoring the EMC light output, and large decrease of light output of several crystals is discussed. BESIII electromagnetic calorimeter works very well and its performance reach the design value.

  15. Electrical Grounding Architecture for Unmanned Spacecraft

    NASA Technical Reports Server (NTRS)

    1998-01-01

    This handbook is approved for use by NASA Headquarters and all NASA Centers and is intended to provide a common framework for consistent practices across NASA programs. This handbook was developed to describe electrical grounding design architecture options for unmanned spacecraft. This handbook is written for spacecraft system engineers, power engineers, and electromagnetic compatibility (EMC) engineers. Spacecraft grounding architecture is a system-level decision which must be established at the earliest point in spacecraft design. All other grounding design must be coordinated with and be consistent with the system-level architecture. This handbook assumes that there is no one single 'correct' design for spacecraft grounding architecture. There have been many successful satellite and spacecraft programs from NASA, using a variety of grounding architectures with different levels of complexity. However, some design principles learned over the years apply to all types of spacecraft development. This handbook summarizes those principles to help guide spacecraft grounding architecture design for NASA and others.

  16. Application of nomographs for analysis and prediction of receiver spurious response EMI

    NASA Astrophysics Data System (ADS)

    Heather, F. W.

    1985-07-01

    Spurious response EMI for the front end of a superheterodyne receiver follows a simple mathematic formula; however, the application of the formula to predict test frequencies produces more data than can be evaluated. An analysis technique has been developed to graphically depict all receiver spurious responses usig a nomograph and to permit selection of optimum test frequencies. The discussion includes the math model used to simulate a superheterodyne receiver, the implementation of the model in the computer program, the approach to test frequency selection, interpretation of the nomographs, analysis and prediction of receiver spurious response EMI from the nomographs, and application of the nomographs. In addition, figures are provided of sample applications. This EMI analysis and prediction technique greatly improves the Electromagnetic Compatibility (EMC) test engineer's ability to visualize the scope of receiver spurious response EMI testing and optimize test frequency selection.

  17. The Electromagnetic Compatibility (EMC) Design Challenge for Scientific Spacecraft Powered by a Stirling Power Converter

    NASA Technical Reports Server (NTRS)

    Sargent, Noel B.

    2001-01-01

    A 55 We free-piston Stirling Technology Demonstration Convertor (TDC) has been tested as part of an evaluation to determine its feasibility as a means for significantly reducing the amount of radioactive material required compared to Radioisotope Thermoelectric Generators (RTGs) to support long-term space science missions. Measurements were made to quantify the low frequency magnetic and electric fields radiated from the Stirling's 80 Hertz (Hz) linear alternator and control electronics in order to determine the magnitude of reduction that will be required to protect sensitive field sensors aboard some science missions. One identified "Solar Probe" mission requires a 100 dB reduction in the low frequency magnetic field over typical military standard design limits, to protect its plasma wave sensor. This paper discusses the electromagnetic interference (EMI) control options relative to the physical design impacts for this power system, composed of 3 basic electrical elements. They are (1) the Stirling Power Convertor with its linear alternator, (2) the power switching and control electronics to convert the 90 V, 80 Hz alternator output to DC for the use of the spacecraft, and (3) the interconnecting wiring including any instrumentation to monitor and control items 1 and 2.

  18. Track propagation methods for the correlation of charged tracks with clusters in the calorimeter of the bar PANDA experiment

    NASA Astrophysics Data System (ADS)

    Nasawasd, T.; Simantathammakul, T.; Herold, C.; Stockmanns, T.; Ritman, J.; Kobdaj, C.

    2018-02-01

    To classify clusters of hits in the electromagnetic calorimeter (EMC) of bar PANDA (antiProton ANnihilation at DArmstadt), one has to match these EMC clusters with tracks of charged particles reconstructed from hits in the tracking system. Therefore the tracks are propagated to the surface of the EMC and associated with EMC clusters which are nearby and below a cut parameter. In this work, we propose a helix propagator to extrapolate the track from the Straw Tube Tracker (STT) to the inner surface of the EMC instead of the GEANE propagator which is already embedded within the PandaRoot computational framework. The results for both propagation methods show a similar quality, with a 30% gain in CPU time when using the helix propagator. We use Monte-Carlo truth information to compare the particle ID of the EMC clusters with the ID of the extrapolated points, thus deciding upon the correctness of the matches. By varying the cut parameter as a function of transverse momentum and particle type, our simulations show that the purity can be increased by 3-5% compared to the default value which is a constant cut in the bar PANDA simulation framework PandaRoot.

  19. Characterization of Different Cable Ferrite Materials to Reduce the Electromagnetic Noise in the 2–150 kHz Frequency Range

    PubMed Central

    Suarez, Adrian; Victoria, Jorge; Alcarria, Antonio; Torres, Jose; Martinez, Pedro A.; Muetsch, Steffen

    2018-01-01

    The gap of standardization for conducted and field coupled electromagnetic interferences (EMI) in the 2–150 kHz frequency range can lead to Electromagnetic Compatibility (EMC) problems. This is caused by power systems such as Pulse Width Modulation (PWM) controlled rectifiers, photovoltaic inverters or charging battery units in electric vehicles. This is a very important frequency spectral due to interferences generated in a wide range of devices and, specifically, communication problems in the new technologies and devices incorporated to the traditional grid to convert it into a Smart Grid. Consequently, it is necessary to provide new solutions to attenuate this kind of interference, which involves finding new materials that are able to filter the electromagnetic noise. This contribution is focused on characterizing the performance of a novel material based on nanocrystalline and comparing it to most common material compositions such as MnZn and NiZn. This research is carried out from the point of view of the manufacturing process, magnetic properties and EMI suppression ability. This last item is carried out through two analysis procedures: a theoretical method by determining the attenuation ratio by measuring impedance parameter and proposing a new empirical technique based on measuring directly the insertion loss parameter. Therefore, the main aim of this characterization process is to determine the performance of nanocrystalline compared to traditional cable ferrite compositions to reduce the interferences in this controversial frequency range. From the results obtained, it is possible to deduce that nanocrystalline cable ferrite provides the best performance to filter the electromagnetic noise in the 2–150 kHz frequency range. PMID:29360754

  20. Characterization of Different Cable Ferrite Materials to Reduce the Electromagnetic Noise in the 2-150 kHz Frequency Range.

    PubMed

    Suarez, Adrian; Victoria, Jorge; Alcarria, Antonio; Torres, Jose; Martinez, Pedro A; Martos, Julio; Soret, Jesus; Garcia-Olcina, Raimundo; Muetsch, Steffen

    2018-01-23

    The gap of standardization for conducted and field coupled electromagnetic interferences (EMI) in the 2-150 kHz frequency range can lead to Electromagnetic Compatibility (EMC) problems. This is caused by power systems such as Pulse Width Modulation (PWM) controlled rectifiers, photovoltaic inverters or charging battery units in electric vehicles. This is a very important frequency spectral due to interferences generated in a wide range of devices and, specifically, communication problems in the new technologies and devices incorporated to the traditional grid to convert it into a Smart Grid. Consequently, it is necessary to provide new solutions to attenuate this kind of interference, which involves finding new materials that are able to filter the electromagnetic noise. This contribution is focused on characterizing the performance of a novel material based on nanocrystalline and comparing it to most common material compositions such as MnZn and NiZn. This research is carried out from the point of view of the manufacturing process, magnetic properties and EMI suppression ability. This last item is carried out through two analysis procedures: a theoretical method by determining the attenuation ratio by measuring impedance parameter and proposing a new empirical technique based on measuring directly the insertion loss parameter. Therefore, the main aim of this characterization process is to determine the performance of nanocrystalline compared to traditional cable ferrite compositions to reduce the interferences in this controversial frequency range. From the results obtained, it is possible to deduce that nanocrystalline cable ferrite provides the best performance to filter the electromagnetic noise in the 2-150 kHz frequency range.

  1. Elimination of Potential Electrical Stress During EMC (CS01) Testing

    NASA Technical Reports Server (NTRS)

    Erickson, Kenneth P.; Whittlesey, Albert C.; Vorperian, Vatche

    2006-01-01

    This viewgraph presentation reviews possible ways to eliminate electrical stress during Electromagneticic Compatibility (EMC) testing. The presentation reviews tests that have had problems due to electrical stress. On December 5, 1995 Cassini Radar instrument failed a functional test in preparation for EMC conducted susceptibility (CSO 1 ) testing. The instrument power supply did not turn on as required, and failure occurred prior to injection of CS test stimulus. A investigation of the failure was conducted. A PSPICE simulation of Cassini Radar 30V line using the EMC test setup was performed; the result of the simulation was an oscillation on the 30V input of the power supply. In another case: on December 28, 1999 an oscillation occurred on the input power line of the SlRTF Infrared Array Camera (IRAC) while preparing to perform CSOI testing, Resulted in damage to flight hardware. Subsequent to failure, JPL provided GSFC history and corrective action from Cassini Radar CSOI test failure GSFC implemented the same corrective action as JPL, except that the value of the resistor connected across the isolation transformer primary winding is 2.5 ohms instead of 50 ohms. Three recommendations are made: (1) Make EMC test community aware of the problem and potential solutions by presenting papers at major environmental test conferences (2) Include warnings and safeguards in EMC test requirements and procedures (3) Try to convince EMC test equipment suppliers to design a CSOl test fixture similar to fixture shown in the diagram

  2. Final Results for the GRC Supporting Technology Development Project for the 110-Watt Stirling Radioisotope Generator (SRG110)

    NASA Technical Reports Server (NTRS)

    Schreiber, Jeffrey G.; Thieme, Lanny G.

    2007-01-01

    From 1999 to 2006, the NASA Glenn Research Center (GRC) supported the development of a high-efficiency, nominal 110-We Stirling Radioisotope Generator (SRG110) for potential use on NASA missions, including deep space missions, Mars rovers, and lunar applications. Lockheed Martin (LM) was the system integrator for the SRG110, under contract to the Department of Energy (DOE). Infinia Corporation (formerly Stirling Technology Company) developed the Stirling convertor, first as a contractor to DOE and then under subcontract to LM. The SRG110 development has been redirected, and recent program changes have been made to significantly increase the specific power of the generator. System development of an Advanced Stirling Radioisotope Generator (ASRG) has now begun, using a lightweight, advanced convertor from Sunpower, Inc. This paper summarizes the results of the supporting technology effort that GRC completed for the SRG110. GRC tasks included convertor extended-duration testing in air and thermal vacuum environments, heater head life assessment, materials studies, permanent magnet aging characterization, linear alternator evaluations, structural dynamics testing, electromagnetic interference (EMI) and electromagnetic compatibility (EMC) characterization, organic materials evaluations, reliability studies, and development of an end-to-end system dynamic model. Related efforts are now continuing in many of these areas to support ASRG development.

  3. Final Results for the GRC Supporting Technology Development Project for the 110-Watt Stirling Radioisotope Generator (SRG110)

    NASA Technical Reports Server (NTRS)

    Schreiber, Jeffrey G.; Thieme, Lanny G.

    2007-01-01

    From 1999-2006, the NASA Glenn Research Center (GRC) supported the development of a high-efficiency, nominal 110-We Stirling Radioisotope Generator (SRG110) for potential use on NASA missions, including deep space missions, Mars rovers, and lunar applications. Lockheed Martin (LM) was the system integrator for the SRG110, under contract to the Department of Energy (DOE). Infinia Corporation (formerly Stirling Technology Company) developed the Stirling convertor, first as a contractor to DOE and then under subcontract to LM. The SRG110 development has been redirected, and recent program changes have been made to significantly increase the specific power of the generator. System development of an Advanced Stirling Radioisotope Generator (ASRG) has now begun, using a lightweight, advanced convertor from Sunpower, Inc. This paper summarizes the results of the supporting technology effort that GRC completed for the SRG110. GRC tasks included convertor extended-duration testing in air and thermal vacuum environments, heater head life assessment, materials studies, permanent magnet aging characterization, linear alternator evaluations, structural dynamics testing, electromagnetic interference (EMI) and electromagnetic compatibility (EMC) characterization, organic materials evaluations, reliability studies, and development of an end-to-end system dynamic model. Related efforts are now continuing in many of these areas to support ASRG development.

  4. Overview of the Orion Vibroacoustic Test Capability at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Hughes, William O.; Hozman, Aron D.; McNelis, Mark E.; Otten, Kim D.

    2008-01-01

    In order to support the environmental test needs for our new Orion and Constellation program, NASA is developing unique world-class test facilities. To optimize this testing of spaceflight hardware while minimizing transportation issues, a one-stop, under one roof test capability is being developed at the Space Power Facility at the NASA Glenn Research Center's Plum Brook Station. This facility will provide the capability to perform the following environmental testing: (1) reverberation acoustic testing, (2) mechanical base-shake sine testing, (3) modal testing, (4) thermal-vacuum testing, and (5) EMI/EMC (electromagnetic interference and compatibility) testing. An overview of this test capability will be provided in this presentation, with special focus on the two new vibroacoustic test facilities currently being designed and built, the Reverberant Acoustic Test Facility (RATF) and the Mechanical Vibration Facility (MVF). Testing of the engineering developmental hardware and qualification hardware of the Orion (Crew Exploration Vehicle) will commence shortly after the facilities are commissioned.

  5. Testing of Unmanned Ground Vehicle (UGV) Systems

    DTIC Science & Technology

    2009-02-12

    Emissions - Intra-system EMC TOP 1-2-51253 TOP 1-2-51154 TOP 2-2-61355 Determines whether the item tested meets the electromagnetic radiation ...effects, static electricity, and lightning criteria and the maximum electromagnetic radiation environment to which the test item may be exposed...Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39-18 2-2-540 Testing of Unmanned Ground Vehicle (UGV) Systems 5c. PROGRAM ELEMENT NUMBER 5d

  6. 21 CFR 874.3305 - Wireless air-conduction hearing aid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...-amplifying device, intended to compensate for impaired hearing that incorporates wireless technology in its...: (1) Appropriate analysis/testing should validate electro magnetic compatibility (EMC) and safety of... technology functions; and (3) Labeling should specify appropriate instructions, warnings, and information...

  7. Simple Statistical Model to Quantify Maximum Expected EMC in Spacecraft and Avionics Boxes

    NASA Technical Reports Server (NTRS)

    Trout, Dawn H.; Bremner, Paul

    2014-01-01

    This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. Test and model data correlation is shown. In addition, this presentation shows application of the power balance and extention of this method to predict the variance and maximum exptected mean of the E-field data. This is valuable for large scale evaluations of transmission inside cavities.

  8. EMC Test Report: StangSat - CubeSat Program

    NASA Technical Reports Server (NTRS)

    Carmody, Lynne M.; Aragona, Peter S.

    2013-01-01

    This report documents the Electromagnetic Interference E M I testing performed on the StangSat; the unit under test (UUT). Testing was per the requirements of MIL STD-461F. The UUT was characterized and passed the radiated emissions (RE102 limit for Spacecraft) testing.

  9. A Measurement of Neutral B Mixing using Di-Lepton Events with the BaBar Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gunawardane, Naveen

    This thesis reports on a measurement of the neutral B meson mixing parameter, Δm d, at the BABAR experiment and the work carried out on the electromagnetic calorimeter (EMC) data acquisition (DAQ) system and simulation software.

  10. Aircraft Electromagnetic Compatibility.

    DTIC Science & Technology

    1987-06-01

    Human Exposure to Radio Frequency Electromagnetic Fields , 300 KiloHertz to 100 GigaHertz." 6. ARINC 429-8, "Digital Information Transfer System (DITS...142 V EXECUTIVE SUMMARY The Aircraft Electromagnetic Compatibility guidelines document deals with electromagnetic compatibility in a... electromagnetic interference paths (figure EI. TYPE PATH 400 Hz Electrostatic MagneticCharge Electric Field Transients 5 R d t Coupling 150/i 300o Wire

  11. Overview and comparative study of GPR international standards and guidelines - COST Action TU1208

    NASA Astrophysics Data System (ADS)

    Pajewski, Lara; Marciniak, Marian; Benedetto, Andrea; Tosti, Fabio

    2016-04-01

    Ground Penetrating Radar (GPR) can be effectively used for non-destructive testing of composite structures and diagnostics affecting the whole life-cycle of civil engineering works. Nevertheless, few recognised international standards exist in this field and inhomogeneous recommendations are present in different countries. Moreover, the levels of knowledge, awareness and experience regarding the use of GPR in civil engineering vary strongly across different European areas. The COST Action TU1208 is working hard on leveraging these differences, by sharing and disseminating knowledge and experience, as well as by developing guidelines and protocols for a safe and effective use of GPR in civil engineering. GPR users need to know which is the best way to conduct GPR measurements and what the quality level for the results should be. The TU1208 guidelines will ensure a higher efficiency and quality of GPR services and they will constitute a scientific basis for the introduction of European Standards on the application of GPR in civil engineering. The aim of this contribution is to present an in-depth overview and critical analysis of the existing GPR international and national standards and guidelines. The main documents considered in our work are listed and briefly described in the following. Three standards are provided by the American Society for Testing and Materials (ASTM), to guide the GPR use for subsurface investigation, evaluation of asphalt-covered concrete bridge decks, and determination of pavement-layer thickness: 1. ASTM D6432-11, Standard Guide for Using the Surface Ground Penetrating Radar Method for Subsurface Investigation, ASTM International, West Conshohocken, PA, 2011, www.astm.org, DOI: 10.1520/D6432-11. 2. ASTM D6087-08, Standard Test Method for Evaluating Asphalt-Covered Concrete Bridge Decks Using Ground Penetrating Radar, ASTM International, West Conshohocken, PA, 2008, www.astm.org, DOI: 10.1520/D6087-08. 3. ASTM D4748-10, Standard Test Method for Determining the Thickness of Bound Pavement Layers Using Short-Pulse Radar, ASTM International, West Conshohocken, PA, 2010, www.astm.org, DOI: 10.1520/D4748-10. Further ASTM standards exist, not focused on GPR but including useful information (details are not provided here, for brevity reasons). There are no standards in Europe, instead, guiding the GPR use for subsurface prospecting and regulating the numerous applications of this non-destructive technique. The following Radio and Telecommunications Terminal Equipment (R&TTE) directive applies to GPR equipment and allows the placing of a GPR product on the European (EU) market for sale: Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999, on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity. Official Journal of the European Union, L 91, 7.4.1999, open access on ec.europa.eu. This document will be repealed, since 13 June 2016, by the following R&TTE directive: Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014, on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment, repealing Directive 1999/5/EC. Official Journal of the European Union, L 153, 22.5.2014, open access on ec.europa. Although conformance to the R&TTE directive allows the placing of a GPR product on the market for sale, it does not give authority for its use. In order to use the equipment, in the majority of EU member countries, a license is required. The license is controlled and issued by the radio administration in each of the member countries. The Electronic Communications Committee (ECC) of the European Conference of Postal and Telecommunications Administrations (CEPT) considers and develops policies on electronic communications activities in European context, taking account of European and international legislations and regulations. There are 48 European countries involved in the CEPT, which cooperate to regulate posts, radio spectrum and communications networks in Europe. The ECC agreed to the decision ECC/DEC/(06)08, specifically referred to GPR and Wall Penetrating Radar (WPR) systems: ECC Decision of 1 December 2006 on the conditions for use of the radio spectrum by Ground- and Wall- Probing Radar (GPR/WPR) imaging systems, 14 December 2006, open access on www.cept.org. This is not legally binding on member countries. It is currently implemented by 25 and partly implemented by 2 of the 48 administrations; 5 further administration are considering and studying the decision. Outside Europe, different approaches exist, ranging from very formal technical approval and licensing conditions to no specific rules. A series of standards and codes, introduced by the European Telecommunications Standards Institute (ETSI), regulate the GPR use and its emissions of electromagnetic radiation in Europe: 1. ETSI EN 301 489-1 v1.9.2, Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements, Sept. 2011, open access on www.etsi.org, Ref. DEN/ERM-EMC-230-32, 45 pp. [7]. This document is a Harmonized European Standard. 2. ETSI EN 301 489-32 v1.1.1, Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 32: Specific conditions for Ground and Wall Probing Radar applications, Sept. 2009, open access on www.etsi.org, Ref. DEN/ERM-EMC-230-32, 12 pp. [8]. This document is currently (May 2015) a Candidate Harmonized European Standard (Telecommunication Series). 3. ETSI EN 302/066-1 v1.2.1, Electromagnetic compatibility and Radio spectrum Matters (ERM); Ground- and Wall- Probing Radar applications (GPR/WPR) imaging systems; Part 1: Technical characteristics and test methods, Dec. 2007, open access on www.etsi.org, Ref. REN/ERM-TG31A-0113-1, 25 pp. [9]. This document is a Harmonized European Standard (Telecommunications series). 4. ETSI EN 302/066-2 v1.2.1, Electromagnetic compatibility and Radio spectrum Matters (ERM); Ground- and Wall- Probing Radar applications (GPR/WPR) imaging systems; Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive, Dec. 2007, open access on www.etsi.org, Ref. REN/ERM-TG31A-0113-2, 12 pp. [10]. This document is a Harmonized European Standard (Telecommunications series). 5. ETSI EG 202 730 v1.1.1, Electromagnetic compatibility and Radio spectrum Matters (ERM); Code of Practice in respect of the control, use and application of Ground Probing Radar (GPR) and Wall Probing Radar (WPR) systems and equipment, Sept. 2009, open access on www.etsi.org, Ref. DEG/ERM-TGUWB-010, 11 pp. [11]. This document is currently (May 2015) an ETSI guide. Few National GPR Guidelines and Standards exist in Europe. In France, the National standard NF S 70-003, Parts 1-3, is concerned with the use of GPR to detect buried utilities. Still in France, Cerema/Ifsttar produced protocols for road inspection. In Germany, the DGZfP e.V. (German Society for Non-Destructive Testing) published a fact sheet called "Merkblatt B10" on the radar method for non-destructive testing in civil engineering (2008). Still in Germany, there is a BASt (Federal Highway Administration) instruction sheet on the use of GPR to gain inventory data of road structure (2003). In Poland, the national regulation of September 24, 1998 (Dz.U. Nr 126 poz. 839) cites 'georadar testing' as a method to investigate the soil structure. In Scandinavia, recommendations for guidelines were developed during the MARA NORD Project (2010-2012) on the use of GPR in asphalt air voids content measurements, in road construction quality control, in bridge deck surveys, in road rehabilitation projects and in site investigations. Acknowledgement This work stems from the research activities of COST (European COoperation in Science and Technology) Action TU1208 "Civil engineering applications of Ground Penetrating Radar." The Authors thank COST (www.cost.eu) for funding the Action TU1208 (www.GPRadar.eu). Part of this work was carried out during the Short-Term Scientific Mission STSM-TU1208-24656 "Comparative study of GPR international standards and guidelines" (Dr Lara Pajewski, Italy, visiting Prof Marian Marciniak, Poland).

  12. 49 CFR 238.425 - Electrical system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...

  13. 49 CFR 238.425 - Electrical system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...

  14. 49 CFR 238.425 - Electrical system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...

  15. 49 CFR 238.225 - Electrical system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...

  16. 49 CFR 238.425 - Electrical system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...

  17. 49 CFR 238.225 - Electrical system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...

  18. 49 CFR 238.225 - Electrical system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...

  19. 49 CFR 238.225 - Electrical system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...

  20. 49 CFR 238.225 - Electrical system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...

  1. 49 CFR 238.425 - Electrical system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...

  2. Bilateral comparison on electric field measurements between TÜBİTAK UME and SASO NMCC

    NASA Astrophysics Data System (ADS)

    Aslan, Çağlar; Alrobaish, Abdullah M.; Şen, Osman

    2017-01-01

    Electromagnetic (EM) probes are widely utilized in the measurement of EM fields for non-ionizing radiation, electromagnetic compatibility (EMC) testing and other applications in the frequency range 5 Hz-60 GHz. They must be calibrated by National Metrology Institutes (NMIs) or accredited calibration laboratories in accordance with international standards such as IEEE 1309. The existing NMIs or emerging NMIs should refer to the international comparison measurements in order to assure the quality of their measurement results. Therefore, the electric field comparison measurements organized by TUBITAK UME were performed between TUBITAK UME and SASO NMCC at the 100 Hz, 1 kHz, 10 MHz, 100 MHz, 1 GHz, 10 GHz and 18 GHz frequencies in order to obtain the correction factors of the electric field probes. The comparison measurements were carried out in accordance with the Technical Protocol prepared by TUBITAK UME. The measurements started in October 2017 and were completed in January 2017. There was good agreement found for the correction factors. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. 78 FR 14013 - Medical Devices; Exemption From Premarket Notification; Class II Devices; Wheelchair Elevator

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-04

    ...: General Requirements for Safety-- Collateral Standard: Electromagnetic Compatibility--Requirements and... electromagnetic compatibility and electrical safety. Firms are now exempt from 510(k) requirements for vertical... Equipment--Part 1-2: General Requirements for Safety--Collateral Standard: Electromagnetic Compatibility...

  4. 75 FR 32943 - Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... basic safety and essential performance--Collateral standard: Electromagnetic compatibility--Requirements... standard: Electromagnetic compatibility--Requirements and tests 5-34 5-53 IEC 60601-1-2 Third edition 2007... for basic safety and essential performance--Collateral standard: Electromagnetic compatibility...

  5. EMC Enhanced Constant ’Z’ Modulator.

    DTIC Science & Technology

    1984-06-01

    TUTHILL, Colonel, USAF Chief, Relilability & Compatibility Division FOR THE COMMANDER: JOHN A. RITZ Acting Chief, Plans Office 0 * - If your address...supply bypasses. 3.2.6 System Testing Breadboard system tests resulted in the replacement of the HP5082-3340 shunt mounted PIN diodes due to a carrer life

  6. Nonlinear system analysis in bipolar integrated circuits

    NASA Astrophysics Data System (ADS)

    Fang, T. F.; Whalen, J. J.

    1980-01-01

    Since analog bipolar integrated circuits (IC's) have become important components in modern communication systems, the study of the Radio Frequency Interference (RFI) effects in bipolar IC amplifiers is an important subject for electromagnetic compatibility (EMC) engineering. The investigation has focused on using the nonlinear circuit analysis program (NCAP) to predict RF demodulation effects in broadband bipolar IC amplifiers. The audio frequency (AF) voltage at the IC amplifier output terminal caused by an amplitude modulated (AM) RF signal at the IC amplifier input terminal was calculated and compared to measured values. Two broadband IC amplifiers were investigated: (1) a cascode circuit using a CA3026 dual differential pair; (2) a unity gain voltage follower circuit using a micro A741 operational amplifier (op amp). Before using NCAP for RFI analysis, the model parameters for each bipolar junction transistor (BJT) in the integrated circuit were determined. Probe measurement techniques, manufacturer's data, and other researcher's data were used to obtain the required NCAP BJT model parameter values. An important contribution included in this effort is a complete set of NCAP BJT model parameters for most of the transistor types used in linear IC's.

  7. Lunar Atmosphere and Dust Environment Explorer Integration and Test

    NASA Technical Reports Server (NTRS)

    Wright, Michael R.; McCormick, John L.

    2010-01-01

    The Lunar Atmosphere and Dust Environment Explorer (LADEE) is a NASA collaborative flight project to explore the lunar exosphere. It is being developed through a unique partnership between NASA's Ames Research Center (ARC) and Goddard Space Flight Center (GSFC). Each center brings its own experience and flight systems heritage to the task of integrating and testing the LADEE subsystems, instruments, and spacecraft. As an "in-house" flight project being implemented at low-cost and moderate risk, LADEE relies on single-string subsystems and protoflight hardware to accomplish its mission. Integration and test (l&T) of the LADEE spacecraft with the instruments will be performed at GSFC, and includes assembly, integration, functional testing, and flight qualification and acceptance testing. Due to the nature of the LADEE mission, l&T requirements include strict contamination control measures and instrument calibration procedures. Environmental testing will include electromagnetic compatibility (EMC), vibro-acoustic testing, and thermal-balance/vacuum. Upon successful completion of spacecraft l&T, LADEE will be launched from NASA's Wallops Flight Facility. Launch of the LADEE spacecraft is currently scheduled for December 2012.

  8. 78 FR 28733 - Medical Devices; General Hospital and Personal Use Monitoring Devices; Classification of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-16

    ... Toxicology Testing. Labeling (dose limits). Electromagnetic incompatibility........ Electromagnetic... analysis and nonclinical testing must validate electromagnetic compatibility performance, wireless... electromagnetic compatibility performance, wireless performance, and electrical safety; and (4) Labeling must...

  9. EMC and power quality standards for 20-kHz power distribution

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.

    1987-01-01

    The Space Station Power Distribution System has been baselined as a sinusoidal single phase, 440 VRMS system. This system has certain unique characteristics directly affecting its application. In particular, existing systematic description and control documents were modified to reflect the high operating frequency. This paper will discuss amendments made on Mil STD 704 (Electrical Power Characteristics), and Mil STD 461-B (Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference). In some cases these amendments reflect changes of several orders of magnitude. Implications and impacts of these changes are discussed.

  10. Maintaining Stability During a Conducted-Ripple EMC Test

    NASA Technical Reports Server (NTRS)

    Vorperian, Vatche

    2007-01-01

    An improved technique, and electronic circuitry to implement the technique, have been developed for a military-standard electromagnetic-compatibility (EMC) test in which one analyzes susceptibility to low-frequency ripple conducted into the equipment under test via a DC power line. In the traditional technique for performing the particular test, the ripple is coupled onto the DC power line via a transformer. Depending upon some design details of the equipment under test, the inductance of the transformer can contribute a degree of instability that results in an oscillation of amplitude large enough to destroy the equipment. It is usually possible to suppress the oscillation by connecting a damping resistor to the primary terminals of the ripple-injection transformer. However, it is important to emphasize the usually in the preceding sentence: sometimes, the resistive damping becomes insufficient to suppress destructive oscillation. In addition, undesirably, the resistor contributes to power dissipation and power demand, and thereby also necessitates the use of a larger ripple voltage amplifier. Yet another disadvantage of the transformer-coupling technique is that the transformer introduces low-frequency distortion of the injected ripple voltage. The improved technique makes it possible to inject ripple with very low distortion at low frequency, without inducing oscillation. In this technique, a transformer is not used: Instead, power is fed to the equipment under test via series power field-effect transistors (FETs) controlled by a summing operational amplifier. One of the inputs to the amplifier controls the DC component of the power-line voltage; the other input, generated by an external oscillator, controls the ripple component. The circuitry for implementing this technique includes panel displays, an internal power supply for the operational amplifier and panel displays, and amplitude controls for the DC and ripple powerline voltage components.

  11. Electronic systems failures and anomalies attributed to electromagnetic interference

    NASA Technical Reports Server (NTRS)

    Leach, R. D. (Editor); Alexander, M. B. (Editor)

    1995-01-01

    The effects of electromagnetic interference can be very detrimental to electronic systems utilized in space missions. Assuring that subsystems and systems are electrically compatible is an important engineering function necessary to assure mission success. This reference publication will acquaint the reader with spacecraft electronic systems failures and anomalies caused by electromagnetic interference and will show the importance of electromagnetic compatibility activities in conjunction with space flight programs. It is also hoped that the report will illustrate that evolving electronic systems are increasingly sensitive to electromagnetic interference and that NASA personnel must continue to diligently pursue electromagnetic compatibility on space flight systems.

  12. 78 FR 1162 - Cardiovascular Devices; Reclassification of External Cardiac Compressor

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-08

    ... safety and electromagnetic compatibility; For devices containing software, software verification... electromagnetic compatibility; For devices containing software, software verification, validation, and hazard... electrical components, appropriate analysis and testing must validate electrical safety and electromagnetic...

  13. 78 FR 35173 - Physical Medicine Devices; Reclassification of Stair-Climbing Wheelchairs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-12

    .... Electromagnetic interference: The device may interfere with the operation of other electrical devices or be... electromagnetic compatibility testing as well as characterization of speed/acceleration, battery longevity, and... electrical safety and electromagnetic compatibility of the device. Performance testing must demonstrate...

  14. 78 FR 14015 - Medical Devices; Exemption From Premarket Notification; Class II Devices; Powered Patient Transport

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-04

    ... for Safety--Collateral Standard: Electromagnetic Compatibility--Requirements and Tests,'' and ASME A18.1 ``Safety Standard for Platform Lifts and Stairway Chair Lifts'') must validate electromagnetic...: Electromagnetic Compatibility--Requirements and Tests,'' and ASME A18.1 ``Safety Standard for Platform Lifts and...

  15. Antenna Measurements: Test & Analysis of the Radiated Emissions from the NASA/Orion Spacecraft - Parachute System Simulator

    NASA Technical Reports Server (NTRS)

    Norgard, John D.

    2012-01-01

    For future NASA Manned Space Exploration of the Moon and Mars, a blunt body capsule, called the Orion Crew Exploration Vehicle (CEV), composed of a Crew Module (CM) and a Service Module (SM), with a parachute decent assembly is planned for reentry back to Earth. A Capsule Parachute Assembly System (CPAS) is being developed for preliminary parachute drop tests at the Yuma Proving Ground (YPG) to simulate high-speed reentry to Earth from beyond Low-Earth-Orbit (LEO) and to provide measurements of landing parameters and parachute loads. The avionics systems on CPAS also provide mission critical firing events to deploy, reef, and release the parachutes in three stages (extraction, drogues, mains) using mortars and pressure cartridge assemblies. In addition, a Mid-Air Delivery System (MDS) is used to separate the capsule from the sled that is used to eject the capsule from the back of the drop plane. Also, high-speed and high-definition cameras in a Video Camera System (VCS) are used to film the drop plane extraction and parachute landing events. To verify Electromagnetic Compatibility (EMC) of the CPAS system from unintentional radiation, Electromagnetic Interference (EMI) measurements are being made inside a semi-anechoic chamber at NASA/JSC at 1m from the electronic components of the CPAS system. In addition, EMI measurements of the integrated CPAS system are being made inside a hanger at YPG. These near-field B-Dot probe measurements on the surface of a parachute simulator (DART) are being extrapolated outward to the 1m standard distance for comparison to the MIL-STD radiated emissions limit.

  16. The Forward Endcap of the Electromagnetic Calorimeter for the PANDA Detector at FAIR

    NASA Astrophysics Data System (ADS)

    Albrecht, Malte; PANDA Collaboration

    2015-02-01

    The versatile 4π-detector PANDA will be built at the Facility for Antiproton and Ion Research (FAIR), an accelerator complex, currently under construction near Darmstadt, Germany. A cooled antiproton beam in a momentum range of 1.5 - 15GeV/c will be provided by the High Energy Storage Ring (HESR). All measurements at PANDA rely on an excellent performance of the detector with respect to tracking, particle identification and energy measurement. The electromagnetic calorimeter (EMC) of the PANDA detector will be equipped with 15744 PbWO4 crystals (PWO-II), which will be operated at a temperature of - 25° C in order to increase the light output. The design of the forward endcap of the EMC has been finalized. The crystals will be read out with Large Area Avalanche Photo Diodes (LAAPDs) in the outer regions and with Vacuum Photo Tetrodes (VPTTs) in the innermost part. Production of photosensor units utilizing charge integrating preamplifiers has begun. A prototype comprised of 216 PbWO4 crystals has been built and tested at various accelerators (CERN SPS, ELSA/Bonn, MAMI/Mainz), where the crystals have been exposed to electron and photon beams of 25MeV up to 15GeV. The results of these test measurements regarding the energy and position resolution are presented.

  17. NASA Applications for Computational Electromagnetic Analysis

    NASA Technical Reports Server (NTRS)

    Lewis, Catherine C.; Trout, Dawn H.; Krome, Mark E.; Perry, Thomas A.

    2011-01-01

    Computational Electromagnetic Software is used by NASA to analyze the compatibility of systems too large or too complex for testing. Recent advances in software packages and computer capabilities have made it possible to determine the effects of a transmitter inside a launch vehicle fairing, better analyze the environment threats, and perform on-orbit replacements with assured electromagnetic compatibility.

  18. Canonical Statistical Model for Maximum Expected Immission of Wire Conductor in an Aperture Enclosure

    NASA Technical Reports Server (NTRS)

    Bremner, Paul G.; Vazquez, Gabriel; Christiano, Daniel J.; Trout, Dawn H.

    2016-01-01

    Prediction of the maximum expected electromagnetic pick-up of conductors inside a realistic shielding enclosure is an important canonical problem for system-level EMC design of space craft, launch vehicles, aircraft and automobiles. This paper introduces a simple statistical power balance model for prediction of the maximum expected current in a wire conductor inside an aperture enclosure. It calculates both the statistical mean and variance of the immission from the physical design parameters of the problem. Familiar probability density functions can then be used to predict the maximum expected immission for deign purposes. The statistical power balance model requires minimal EMC design information and solves orders of magnitude faster than existing numerical models, making it ultimately viable for scaled-up, full system-level modeling. Both experimental test results and full wave simulation results are used to validate the foundational model.

  19. Missile telemetry systems for flight tests and EMC tests on EED's

    NASA Astrophysics Data System (ADS)

    Freymann, D.

    1985-06-01

    This paper describes telemetry systems developed for use in the 'Roland', 'MLRS AT2' and 'Kormoran' missiles. The main design effort required to obtain a high performance of telemetry data acquisition and transmission under extreme environmental conditions are discussed, along with test results. Considered are different types of PCM telemetry systems where the data is either transmitted directly to the ground via an RF or fiber optic link or stored in an onboard solid-state memory. The safety of EEDs in the presence of unwanted electromagnetic fields or currents is very important in weapon-systems. Therefore another type of telemetry system is reported here allowing the measurement of extremely small DC- and RF-currents induced on EEDs during EMC ground-tests. These telemetry signals are transmitted via fiber optics, to avoid additional coupling. Finally, there is a brief commentary on the future design philosophy of missile telemetry systems.

  20. Pulsed magnetic field excitation sensitivity of match-type electric blasting caps

    NASA Astrophysics Data System (ADS)

    Parson, Jonathan; Dickens, James; Walter, John; Neuber, Andreas A.

    2010-10-01

    This paper presents a study on energy deposition and electromagnetic compatibility of match-type electroexplosive devices (EEDs), which recently have found more usage in pulsed power environments with high electromagnetic interference (EMI) background. The sensitivity of these devices makes them dangerous to intended and unintended radiation produced by devices commonly used in pulsed power environments. Match-type EEDs have been found to be susceptible to such low levels of energy (7-8 mJ) that safe operation of these EEDs is vital when in use near devices that produce high levels of pulsed EMI. The scope of this paper is to provide an investigation that incorporates results of similar studies to provide detonation characteristics of these EEDs. The three topics included in this study are sensitivity testing, modeling of the thermodynamic heat propagation, and electromagnetic compatibility from pulsed electromagnetic radiation. The thermodynamic joule heating of the primary explosive has been modeled by a solution to the 1D heat equation. A simple pulsed generator, Marx generator with an inductive load, was used for the electromagnetic compatibility assessment of the coupled field between the pulse generator and shorted EED. The results of the electromagnetic compatibility assessment relate the resistive, inductive, and capacitive components of the pulse generator to the area of the shorted EED.

  1. Pulsed magnetic field excitation sensitivity of match-type electric blasting caps.

    PubMed

    Parson, Jonathan; Dickens, James; Walter, John; Neuber, Andreas A

    2010-10-01

    This paper presents a study on energy deposition and electromagnetic compatibility of match-type electroexplosive devices (EEDs), which recently have found more usage in pulsed power environments with high electromagnetic interference (EMI) background. The sensitivity of these devices makes them dangerous to intended and unintended radiation produced by devices commonly used in pulsed power environments. Match-type EEDs have been found to be susceptible to such low levels of energy (7-8 mJ) that safe operation of these EEDs is vital when in use near devices that produce high levels of pulsed EMI. The scope of this paper is to provide an investigation that incorporates results of similar studies to provide detonation characteristics of these EEDs. The three topics included in this study are sensitivity testing, modeling of the thermodynamic heat propagation, and electromagnetic compatibility from pulsed electromagnetic radiation. The thermodynamic joule heating of the primary explosive has been modeled by a solution to the 1D heat equation. A simple pulsed generator, Marx generator with an inductive load, was used for the electromagnetic compatibility assessment of the coupled field between the pulse generator and shorted EED. The results of the electromagnetic compatibility assessment relate the resistive, inductive, and capacitive components of the pulse generator to the area of the shorted EED.

  2. High temperature superconductors applications in telecommunications

    NASA Technical Reports Server (NTRS)

    Kumar, A. Anil; Li, Jiang; Zhang, Ming Fang

    1995-01-01

    The purpose of this paper is twofold: (1) to discuss high temperature superconductors with specific reference to their employment in telecommunications applications; and (2) to discuss a few of the limitations of the normally employed two-fluid model. While the debate on the actual usage of high temperature superconductors in the design of electronic and telecommunications devices - obvious advantages versus practical difficulties - needs to be settled in the near future, it is of great interest to investigate the parameters and the assumptions that will be employed in such designs. This paper deals with the issue of providing the microwave design engineer with performance data for such superconducting waveguides. The values of conductivity and surface resistance, which are the primary determining factors of a waveguide performance, are computed based on the two-fluid model. A comparison between two models - a theoretical one in terms of microscopic parameters (termed Model A) and an experimental fit in terms of macroscopic parameters (termed Model B) - shows the limitations and the resulting ambiguities of the two-fluid model at high frequencies and at temperatures close to the transition temperature. The validity of the two-fluid model is then discussed. Our preliminary results show that the electrical transport description in the normal and superconducting phases as they are formulated in the two-fluid model needs to be modified to incorporate the new and special features of high temperature superconductors. Parameters describing the waveguide performance - conductivity, surface resistance and attenuation constant - will be computed. Potential applications in communications networks and large scale integrated circuits will be discussed. Some of the ongoing work will be reported. In particular, a brief proposal is made to investigate of the effects of electromagnetic interference and the concomitant notion of electromagnetic compatibility (EMI/EMC) of high T(sub c) superconductors.

  3. High temperature superconductors applications in telecommunications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, A.A.; Li, J.; Zhang, M.F.

    1994-12-31

    The purpose of this paper is twofold: to discuss high temperature superconductors with specific reference to their employment in telecommunications applications; and to discuss a few of the limitations of the normally employed two-fluid model. While the debate on the actual usage of high temperature superconductors in the design of electronic and telecommunications devices-obvious advantages versus practical difficulties-needs to be settled in the near future, it is of great interest to investigate the parameters and the assumptions that will be employed in such designs. This paper deals with the issue of providing the microwave design engineer with performance data formore » such superconducting waveguides. The values of conductivity and surface resistance, which are the primary determining factors of a waveguide performance, are computed based on the two-fluid model. A comparison between two models-a theoretical one in terms of microscopic parameters (termed Model A) and an experimental fit in terms of macroscopic parameters (termed Model B)-shows the limitations and the resulting ambiguities of the two-fluid model at high frequencies and at temperatures close to the transition temperature. The validity of the two-fluid model is then discussed. Our preliminary results show that the electrical transport description in the normal and superconducting phases as they are formulated in the two-fluid model needs to be modified to incorporate the new and special features of high temperature superconductors. Parameters describing the waveguide performance-conductivity, surface resistance and attenuation constant-will be computed. Potential applications in communications networks and large scale integrated circuits will be discussed. Some of the ongoing work will be reported. In particular, a brief proposal is made to investigate of the effects of electromagnetic interference and the concomitant notion of electromagnetic compatibility (EMI/EMC) of high T{sub c} superconductors.« less

  4. Electromagnetic Spectrum Test and Evaluation Process

    DTIC Science & Technology

    2010-01-01

    HERO , hazards of electromagnetic radiation to ordnance ; HERP, hazards of electromagnetic radiation to personnel; HERF, hazards of electromagnetic ... electromagnetic pulse (EMP); electronic protection; electrostatic dis- charge (ESD); hazards of electromagnetic radi- ation to personnel (HERP), ordnance ...including ordnance containing electrically initiated devices, to be mutually compatible in their intended

  5. Electromagnetic compatibility test report for the tethered satellite data acquisition and control assembly

    NASA Astrophysics Data System (ADS)

    Hoskins, Douglas; Snead, Robert

    1988-05-01

    This report details the results of an electromagnetic compatibility test on the SCI Systems Data Acquisition and Control Assembly (DACA). This assembly is an electronic processor which controls the central communication link from the Tethered Satellite System (TSS) to the Space Transportation System Orbiter Space Shuttle.

  6. 76 FR 44489 - Medical Devices; Neurological Devices; Classification of Repetitive Transcranial Magnetic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-26

    ...; Hazards caused by electromagnetic interference and electrostatic discharge hazards; and Hearing loss. FDA... electromagnetic Electromagnetic compatibility. interference and electrostatic discharge hazards. Labeling. Hearing...

  7. Intrasystem Electromagnetic Compatibility Analysis Program. Volume 1. User’s Manual Engineering Section

    DTIC Science & Technology

    1974-12-01

    AD-A008 526 INTRASYSTEM ELECTROMAGNETIC COMPATI- BILITY ANALYSIS PROGRAM. VOLUME I. USER’S MANUAL ENGINEERING SECTION J. L. Bogdanor , et al McDonnell...e) 8 CONTRACT OR GRANT NUMBERfs) J.L. Bogdanor F30602-72-C-0277 R.A. Pearlman M.D. Siegel PERFORMING ORGANIZATION NAME AND ADDRESS I0 PROGRAM ELEMENT...June 1968. 14. J. L. Bogdanor , M. D. Siegel, G. L. Weinstock, "Intra-Vehicle Electromagnetic Compatibility Analysis," AFAL-TR-71-155, July 1971. 15

  8. Vegetation Use for Resolving Electromagnetic Compatibility and Ecology Issues

    NASA Astrophysics Data System (ADS)

    Zvezdina, M. Yu; Shokova, Yu A.; Cherckesova, L. V.; Golovko, T. M.; Cherskaya, A. A.

    2017-05-01

    The wide spread of Information and Communication Technologies and the development of Internet-enabled mobile applications have aggravated electromagnetic compatibility and ecology problems. Inability to excite electromagnetic field of a desired structure and strength with traditional approaches actualizes additional actions, including providing diffraction on propagation path, to resolve these issues. Diffraction on a stand-alone obstacle along the propagation path and the one on set of obstacles near receive antenna location can be considered as the additional actions in ultrashort band. The accomplished studies have shown that one the most effective means to lower electromagnetic field strength is to shield the receive antenna with vegetation from jamming radio equipment. Moreover, vegetation resolves electromagnetic ecology issues, for the energy flux density can be lowered by about two orders of magnitude.

  9. Study on the electromagnetic radiation characteristics of discharging excimer laser system

    NASA Astrophysics Data System (ADS)

    Zhao, Duliang; Liang, Xu; Fang, Xiaodong; Wang, Qingsheng

    2016-10-01

    Excimer laser in condition of high voltage, large current and fast discharge will produce strong electromagnetic pulse radiation and electromagnetic interference on the around electrical equipment. The research on characteristics and distribution of excimer laser electromagnetic radiation could provide important basis for electromagnetic shielding and suppressing electromagnetic interference, and further improving the electromagnetic compatibility of system. Firstly, electromagnetic radiation source is analyzed according to the working principle of excimer laser. The key test points of the electromagnetic radiation, hydrogen thyratron, main discharge circuit and laser outlet, are determined by the mechanical structure and the theory of electromagnetic radiation. Secondly, characteristics of electromagnetic field were tested using a near field probe on the key positions of the vertical direction at 20, 50, and 80 cm, respectively. The main radiation frequencies and the radiation field characteristics in the near field are obtained. The experimental results show that the main radiation frequencies distribute in 47, 65, and 130 MHz for electric field and the main radiation frequencies distribute in 34, 100, and 165 MHz for magnetic field. The intensity of electromagnetic field decreases rapidly with the increase of test distance. The higher the frequency increases, the faster the amplitude attenuate. Finally, several electromagnetic interference suppression measurement methods are proposed from the perspective of electromagnetic compatibility according to the test results.

  10. Investigation of the vibration and EMC characteristics of miniature Stirling electric coolers for space applications

    NASA Astrophysics Data System (ADS)

    Kondratjev, V.; Gostilo, V.; Owens, anb A.

    2017-08-01

    We present the results of an investigation into the detrimental effects that electromechanical coolers can have on the spectral performance of compact, large volume HPGe spectrometers for space applications. Both mechanical vibration and electromagnetic pickup effects were considered, as well as a comparative assessment between three miniature Stirling cycle coolers—two Ricor model K508 coolers and one Thales model RM3 cooler. In spite of the limited number of coolers tested, the following conclusions can be made. There are significant differences in the vibration characteristics not only between the various types of cooler but also between coolers of the same type. It was also found that compared to the noise induced by mechanical vibrations, electromagnetic interference emanating from the embedded controllers does not significantly impact the energy resolution of detectors.

  11. High Speed Link Radiated Emission Reduction

    NASA Astrophysics Data System (ADS)

    Bisognin, P.; Pelissou, P.; Cissou, R.; Giniaux, M.; Vargas, O.

    2016-05-01

    To control the radiated emission of high-speed link and associated unit, the current approach is to implement overall harness shielding on cables bundles. This method is very efficient in the HF/ VHF (high frequency/ very high frequency) and UHF (ultra-high frequency) ranges when the overall harness shielding is properly bonded on EMC back-shell. Unfortunately, with the increasing frequency, the associated half wavelength matches with the size of Sub-D connector that is the case for the L band. Therefore, the unit connectors become the main source of interference emission. For the L-band and S-band, the current technology of EMC back-shell leaves thin aperture matched with the L band half wavelength and therefore, the shielding effectiveness is drastically reduced. In addition, overall harness shielding means significant increases of the harness mass.Airbus D&S Toulouse and Elancourt investigated a new solution to avoid the need of overall harness shielding. The objective is to procure EM (Electro-Magnetic) clean unit connected to cables bundles free of any overall harness shielding. The proposed solution is to implement EMC common mode filtering on signal interfaces directly on unit PCB as close as possible the unit connector.Airbus D&S Elancourt designed and manufactured eight mock-ups of LVDS (Low Voltage Differential Signaling) interface PCBs' with different solutions of filtering. After verification of the signal integrity, three mock-ups were retained (RC filter and two common mode choke coil) in addition to the reference one (without EMC filter).Airbus D&S Toulouse manufactured associated LVDS cable bundles and integrated the RX (Receiver) and TX (Transmitter) LVDS boards in shielded boxes.Then Airbus D&S performed radiated emission measurement of the LVDS links subassemblies (e.g. RX and TX boxes linked by LVDS cables) according to the standard test method. This paper presents the different tested solutions and main conclusions on the feasibility of such approach.

  12. Electromagnetic inhibition of high frequency thermal bonding machine

    NASA Astrophysics Data System (ADS)

    He, Hong; Zhang, Qing-qing; Li, Hang; Zhang, Da-jian; Hou, Ming-feng; Zhu, Xian-wei

    2011-12-01

    The traditional high frequency thermal bonding machine had serious radiation problems at dominant frequency, two times frequency and three times frequency. Combining with its working principle, the problems of electromagnetic compatibility were studied, three following measures were adopted: 1.At the head part of the high frequency thermal bonding machine, resonant circuit attenuator was designed. The notch groove and reaction field can make the radiation being undermined or absorbed; 2.The electromagnetic radiation shielding was made for the high frequency copper power feeder; 3.Redesigned the high-frequency oscillator circuit to reduce the output of harmonic oscillator. The test results showed that these measures can make the output according with the national standard of electromagnetic compatibility (GB4824-2004-2A), the problems of electromagnetic radiation leakage can be solved, and good social, environmental and economic benefits would be brought.

  13. Thermal Expansion Behavior of Hot-Pressed Engineered Matrices

    NASA Technical Reports Server (NTRS)

    Raj, S. V.

    2016-01-01

    Advanced engineered matrix composites (EMCs) require that the coefficient of thermal expansion (CTE) of the engineered matrix (EM) matches those of the fiber reinforcements as closely as possible in order to reduce thermal compatibility strains during heating and cooling of the composites. The present paper proposes a general concept for designing suitable matrices for long fiber reinforced composites using a rule of mixtures (ROM) approach to minimize the global differences in the thermal expansion mismatches between the fibers and the engineered matrix. Proof-of-concept studies were conducted to demonstrate the validity of the concept.

  14. 21 CFR 890.3930 - Wheelchair elevator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... for Safety—Collateral Standard: Electromagnetic Compatibility—Requirements and Tests,” and ASME A18.1 “Safety Standard for Platform Lifts and Stairway Chair Lifts”) must validate electromagnetic compatibility...

  15. 21 CFR 890.3930 - Wheelchair elevator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... for Safety—Collateral Standard: Electromagnetic Compatibility—Requirements and Tests,” and ASME A18.1 “Safety Standard for Platform Lifts and Stairway Chair Lifts”) must validate electromagnetic compatibility...

  16. The Influence of Modulated Signal Risetime in Flight Electronics Radiated Immunity Testing with a Mode-Stirred Chamber

    NASA Technical Reports Server (NTRS)

    Ely, Jay J.; Nguyen, Truong X.; Scearce, Stephen A.

    2000-01-01

    For electromagnetic immunity testing of an electronic system, it is desirable to demonstrate its functional integrity when exposed to the full range and intensity of environmental electromagnetic threats that may be encountered over its operational life. As part of this, it is necessary to show proper system operation when exposed to representative threat signal modulations. Modulated signal transition time is easily overlooked, but can be highly significant to system susceptibility. Radiated electromagnetic field immunity testing is increasingly being performed in Mode Stirred Chambers. Because the peak field vs. time relationship is affected by the operation of a reverberating room, it is important to understand how the room may influence any input signal modulation characteristics. This paper will provide insight into the field intensity vs. time relationship within the test environment of a mode stirred chamber. An understanding of this relationship is important to EMC engineers in determining what input signal modulation characteristics will be transferred to the equipment under test. References will be given for the development of this topic, and experimental data will be presented

  17. 21 CFR 890.5150 - Powered patient transport.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Standard: Electromagnetic Compatibility—Requirements and Tests,” and ASME A18.1 “Safety Standard for Platform Lifts and Stairway Chair Lifts”) must validate electromagnetic compatibility and electrical safety...

  18. 21 CFR 890.5150 - Powered patient transport.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Standard: Electromagnetic Compatibility—Requirements and Tests,” and ASME A18.1 “Safety Standard for Platform Lifts and Stairway Chair Lifts”) must validate electromagnetic compatibility and electrical safety...

  19. Feasibility and systems definition study for microwave multi-application payload (MMAP)

    NASA Technical Reports Server (NTRS)

    Horton, J. B.; Allen, C. C.; Massaro, M. J.; Zemany, J. L.; Murrell, J. W.; Stanhouse, R. W.; Condon, G. P.; Stone, R. F.

    1977-01-01

    There were three Shuttle/Spacelab experiments: adaptive multibeam phased array antenna (AMPA) experiment, electromagnetic environment experiment (EEE), and millimeter wave communications experiment (MWCE). Work on the AMPA experiment was completed. Results included are definition of operating modes, sequence of operation, radii of operation about several ground stations, signal format, foot prints of typical orbits and preliminary definition of ground and user terminals. Definition of the MOD I EEE included conceptual hardware designs, spacelab interfaces, preliminary data handling methods, experiment tests and verification, and EMC studies. The MWCE was defined conceptually for a steerable high gain antenna.

  20. Advanced Composite Aircraft Electromagnetic Design and Synthesis

    DTIC Science & Technology

    1980-05-01

    Naval Air Systems Command, July 1978. 9. J.L. Bogdanor , R.A. Pearlman, and M.D. Siegel, Intrasystem Electromagnetic Compatibility Analysis Program...F30602-72-C-0277, RADC-TR-74-342, December 1974. 11. J.L. Bogdanor , R.A. Pearlman, and M.D. Siegel, Intrasystem Electromagnetic Comptibility Analysis

  1. Morphological and electrical properties of epoxy-based composites reinforced with exfoliated graphite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamberti, Patrizia; Spinelli, Giovanni, E-mail: gspinelli@unisa.it; Tucci, Vincenzo

    An experimental study has been carried out to prepare and characterize epoxy/amine-based composites filled with different percentages of partially exfoliated graphite (i.e. pEG) particles having an exfoliation degree of 56% in order to analyze the effect of the filler amounts on the electrical properties of the resulting nanocomposites. Moreover, in order to fully investigate the direct relationship between the physical properties of the employed filler and the results of the electrical characterization, a structural and morphological characterization of the pEG samples is carried out by means of various type of analysis such as X-ray diffraction patterns, micro-Raman and Scanning Electronmore » Microscopy (SEM) images. The DC electrical characterization reveals a percolation thresholds (EPT) that falls in the range [2–3] wt% and an electrical conductivity of about 0.66 S/m at the highest filler loading (6.5 wt%). From the analysis of the percolative curve it is possible to derive the percolation law parameters and in particular the critical exponent t, whose value (i.e. 1.2) reflects an effective 2D organization of the percolating structure consistent with the type of filler used (2-dimensional). Finally, an extensive analysis concerning the electrical properties in the frequency domain has been carried out in order to evaluate the effectiveness of pEG-loaded composites in terms of electromagnetic interference compatibility (EMC) and their applicability as radar absorbers materials (RAMs).« less

  2. The Effect of Epoxy Molding Compound Floor Life to Reliability Performance and mold ability for QFN Package

    NASA Astrophysics Data System (ADS)

    Peanpunga, Udom; Ugsornrat, Kessararat; Thorlor, Panakamol; Sumithpibul, Chalermsak

    2017-09-01

    This research studied about an epoxy molding compound (EMC) floor life to reliability performance of integrated circuit (IC) package. Molding is the process for protecting the die of IC package form mechanical and chemical reaction from external environment by shaping EMC. From normal manufacturing process, the EMC is stored in the frozen at 5oC and left at around room temperature for aging time or floor life before molding process. The EMC floor life effect to its properties and reliability performance of IC package. Therefore, this work interested in varied the floor life of EMC before molding process to analyze properties of EMC such as spiral flow length, gelation time, and viscosity. In experiment, the floor life of EMC was varied to check the effect of its property to reliability performance. The EMC floor life were varied from 0 hours to 60 hours with a step of 12 hours and observed wire sweep, incomplete EMC, and delamination inside the packages for 3x3, 5x5 and 8x8 mm2 of QFN packages. The evaluation showed about clearly effect of EMC floor life to IC packaging reliability. EMC floor life is not any concern for EMC property, moldabilty, and reliability from 0 hours to 48 hours for molding process of 3x3,5x5 and 8x8 mm2 QFN packaging manufacturing

  3. Marshall Space Flight Center Electromagnetic Compatibility Design and Interference Control (MEDIC) handbook

    NASA Astrophysics Data System (ADS)

    Clark, T. L.; McCollum, M. B.; Trout, D. H.; Javor, K.

    1995-06-01

    The purpose of the MEDIC Handbook is to provide practical and helpful information in the design of electrical equipment for electromagnetic compatibility (EMS). Included is the definition of electromagnetic interference (EMI) terms and units as well as an explanation of the basic EMI interactions. An overview of typical NASA EMI test requirements and associated test setups is given. General design techniques to minimize the risk of EMI and EMI suppression techniques at the board and equipment interface levels are presented. The Handbook contains specific EMI test compliance design techniques and retrofit fixes for noncompliant equipment. Also presented are special tests that are useful in the design process or in instances of specification noncompliance.

  4. Marshall Space Flight Center Electromagnetic Compatibility Design and Interference Control (MEDIC) handbook

    NASA Technical Reports Server (NTRS)

    Clark, T. L.; Mccollum, M. B.; Trout, D. H.; Javor, K.

    1995-01-01

    The purpose of the MEDIC Handbook is to provide practical and helpful information in the design of electrical equipment for electromagnetic compatibility (EMS). Included is the definition of electromagnetic interference (EMI) terms and units as well as an explanation of the basic EMI interactions. An overview of typical NASA EMI test requirements and associated test setups is given. General design techniques to minimize the risk of EMI and EMI suppression techniques at the board and equipment interface levels are presented. The Handbook contains specific EMI test compliance design techniques and retrofit fixes for noncompliant equipment. Also presented are special tests that are useful in the design process or in instances of specification noncompliance.

  5. Hearing aid-compatible mobile handsets, petition of American National Standards Committee C63 (EMC) ANSO ASC C63 (TM). Final rule.

    PubMed

    2008-05-07

    The Federal Communications Commission (Commission) adopts various proposals to amend its hearing aid compatibility policies and requirements pertaining to wireless services, including modifications and other requirements along the framework proposed in a consensus plan (Joint Consensus Plan) developed jointly by industry and representatives for the deaf and hard of hearing community. The Commission anticipates that these rule changes, taken together and largely supported by manufacturers, service providers, and consumers with hearing loss, will meet statutory obligations to ensure reasonable access to telephone service by persons with impaired hearing. These requirements are intended to benefit wireless users in the deaf and hard of hearing community, including the most disadvantaged who are more likely to rely on telecoil-equipped hearing aids, as well as to ensure that these consumers have a variety of handsets available to them, including handsets with innovative features.

  6. Cost and Savings Estimates the Air Force Used to Decide Against Relocating the Electromagnetic Compatibility Analysis Center from Annapolis, Maryland, to Duluth, Minnesota.

    DTIC Science & Technology

    1983-03-09

    that maximize electromagnetic compatibility potential. -- Providing direct assistance on an reimbursable basis to DOD and other Government agencies on...value, we estimated that reimburs - able real estate expenses would average about $6,458 rather than $4,260 included in the Air Force estimate. When the...of estimated reimbursement was assumed to be necessary to encourage the relocation of more professional employees and increase their estimated

  7. Inductive Interference in Rapid Transit Signaling Systems. Volume 3. Data and Test Results.

    DOT National Transportation Integrated Search

    1986-11-01

    This report presents comparative inductive interference data obtained from four U.S. rapid transit systems employing chopper propulsion control, as part of the Rail Transit Electromagnetic Interference/Electromagnetic Compatibility program conducted ...

  8. The prognostic value of visually assessing enamel microcracks: Do debonding and adhesive removal contribute to their increase?

    PubMed

    Dumbryte, Irma; Jonavicius, Tomas; Linkeviciene, Laura; Linkevicius, Tomas; Peciuliene, Vytaute; Malinauskas, Mangirdas

    2016-05-01

    To find a correlation between the severity of enamel microcracks (EMCs) and their increase during debonding and residual adhesive removal (RAR). Following their examination with scanning electron microscopy (SEM), 90 extracted human premolars were divided into three groups of 30: group 1, teeth having pronounced EMCs (visible with the naked eye under normal room illumination); group 2, teeth showing weak EMCs (not apparent under normal room illumination but visible by SEM); and group 3, a control group. EMCs have been classified into weak and pronounced, based on their visibility. Metal brackets (MB) and ceramic brackets (CB), 15 of each type, were bonded to all the teeth from groups 1 and 2. Debonding was performed with pliers, followed by RAR. The location, length, and width of the longest EMCs were measured using SEM before and after debonding. The mean overall width (Woverall) was higher for pronounced EMCs before and after debonding CB (P < .05), and after the removal of MB. Pronounced EMCs showed greater length values using both types of brackets. After debonding, the increase in Woverall of pronounced EMCs was 0.57 µm with MB (P < .05) and 0.30 µm with CB; for weak EMCs, - 0.32 µm with MB and 0.30 µm with CB. Although the teeth having pronounced EMCs showed higher width and length values, this did not predispose to greater EMCs increase after debonding MB and CB followed by RAR.

  9. Inductive interference in rapid transit signaling systems. volume 2. suggested test procedures.

    DOT National Transportation Integrated Search

    1987-03-31

    These suggested test procedures have been prepared in order to develop standard methods of analysis and testing to quantify and resolve issues of electromagnetic compatibility in rail transit operations. Electromagnetic interference, generated by rai...

  10. Efficient replication of the novel human betacoronavirus EMC on primary human epithelium highlights its zoonotic potential.

    PubMed

    Kindler, Eveline; Jónsdóttir, Hulda R; Muth, Doreen; Hamming, Ole J; Hartmann, Rune; Rodriguez, Regulo; Geffers, Robert; Fouchier, Ron A M; Drosten, Christian; Müller, Marcel A; Dijkman, Ronald; Thiel, Volker

    2013-02-19

    The recent emergence of a novel human coronavirus (HCoV-EMC) in the Middle East raised considerable concerns, as it is associated with severe acute pneumonia, renal failure, and fatal outcome and thus resembles the clinical presentation of severe acute respiratory syndrome (SARS) observed in 2002 and 2003. Like SARS-CoV, HCoV-EMC is of zoonotic origin and closely related to bat coronaviruses. The human airway epithelium (HAE) represents the entry point and primary target tissue for respiratory viruses and is highly relevant for assessing the zoonotic potential of emerging respiratory viruses, such as HCoV-EMC. Here, we show that pseudostratified HAE cultures derived from different donors are highly permissive to HCoV-EMC infection, and by using reverse transcription (RT)-PCR and RNAseq data, we experimentally determined the identity of seven HCoV-EMC subgenomic mRNAs. Although the HAE cells were readily responsive to type I and type III interferon (IFN), we observed neither a pronounced inflammatory cytokine nor any detectable IFN responses following HCoV-EMC, SARS-CoV, or HCoV-229E infection, suggesting that innate immune evasion mechanisms and putative IFN antagonists of HCoV-EMC are operational in the new host. Importantly, however, we demonstrate that both type I and type III IFN can efficiently reduce HCoV-EMC replication in HAE cultures, providing a possible treatment option in cases of suspected HCoV-EMC infection. IMPORTANCE A novel human coronavirus, HCoV-EMC, has recently been described to be associated with severe respiratory tract infection and fatalities, similar to severe acute respiratory syndrome (SARS) observed during the 2002-2003 epidemic. Closely related coronaviruses replicate in bats, suggesting that, like SARS-CoV, HCoV-EMC is of zoonotic origin. Since the animal reservoir and circumstances of zoonotic transmission are yet elusive, it is critically important to assess potential species barriers of HCoV-EMC infection. An important first barrier against invading respiratory pathogens is the epithelium, representing the entry point and primary target tissue of respiratory viruses. We show that human bronchial epithelia are highly susceptible to HCoV-EMC infection. Furthermore, HCoV-EMC, like other coronaviruses, evades innate immune recognition, reflected by the lack of interferon and minimal inflammatory cytokine expression following infection. Importantly, type I and type III interferon treatment can efficiently reduce HCoV-EMC replication in the human airway epithelium, providing a possible avenue for treatment of emerging virus infections.

  11. Expression of hypoxia-inducible 2 (HIG2) protein in uterine cancer.

    PubMed

    Nishimura, S; Tsuda, H; Nomura, H; Kataoka, F; Chiyoda, T; Tanaka, H; Tanaka, K; Susumu, N; Aoki, D

    2011-01-01

    For both cervical cancer (UCC) and endometrial cancer (EMC) there are no effective prognostic markers. In this study, we evaluated HIG2 protein expression in 332 uterine cancers (186 UCCs and 146 EMCs) and examined the relationship between HIG2 protein expression and clinical factors, including prognosis. Totally, HIG2 expression was detected in 58% of UCC and 66% of EMC. However, there was no significant relationship between HIG2 expression and age, clinical stage and histology in either UCC or EMC. In addition, HIG2 protein expression was not related to prognosis of UCC or EMC. The positivity rate of HIG2 protein was 56% and 61% in early-stage UCC and EMC, respectively and 67% in non-squamous cell carcinoma of UCC. The positivity rate of HIG2 protein was high even in early-stage UCC and EMC

  12. Development of the Electromagnetic Continuous Casting Technology for of Magnesium Alloys

    NASA Astrophysics Data System (ADS)

    Park, Joon-Pyo; Kim, Myoung-Gyun; Kim, Jong-Ho; Lee, Gyu-Chang

    Currently, magnesium billets produced by ingot casting or direct chill casting process, result in low-quality surfaces and low productivity, Continuous casting technology to solve these problem has not only high-quality surface billets with fine-grained and homogeneous microstructure but also cost down. The latent heat of fusion per weight (J/g) of magnesium is similar to other metals, however, considering the heat emitted to the mold surface during continuous casting in meniscus region and converting it to the latent heat of fusion per volume, magnesium will be rapidly solidified in the mold during continuous casting, which induces subsequent surface defect formation. In this study, electromagnetic casting and stirring (EMC and EMS) techniques are proposed to control solidification process conveniently by compensating the low latent heat of solidification by volume and to fabricate magnesium billet with high-quality surface. This technique was extended to large scale billets up to 300 mm diameter and continuous casting was successfully conducted. Then magnesium billet was used for the fabrication of prototype automobile pulley.

  13. Development of Simulated Disturbing Source for Isolation Switch

    NASA Astrophysics Data System (ADS)

    Cheng, Lin; Liu, Xiang; Deng, Xiaoping; Pan, Zhezhe; Zhou, Hang; Zhu, Yong

    2018-01-01

    In order to simulate the substation in the actual scene of the harsh electromagnetic environment, and then research on electromagnetic compatibility testing of electronic instrument transformer, On the basis of the original isolation switch as a harassment source of the electronic instrument transformer electromagnetic compatibility test system, an isolated switch simulation source system was developed, to promote the standardization of the original test. In this paper, the circuit breaker is used to control the opening and closing of the gap arc to simulate the operating of isolating switch, and the isolation switch simulation harassment source system is designed accordingly. Comparison with the actual test results of the isolating switch, it is proved that the system can meet the test requirements, and the simulation harassment source system has good stability and high reliability.

  14. Epithelial-myoepithelial carcinoma with myoepithelial anaplasia: report of a case with cytologic findings of a rare variant.

    PubMed

    Suzuki, Takashi; Murata, Shin-ichi; Yamaguchi, Hiroshi; Shimizu, Yoshihiko; Shimizu, Michio

    2010-01-01

    Epithelial-myoepithelial carcinoma (EMC) is usually a low grade malignancy with rare mortality. Rare aggressive variants of EMC, dedifferentiated EMC and EMC with myoepithelial anaplasia have been reported. An 81-year-old man presented with EMC of the parotid gland showing the classical type at the time of initial presentation and a high grade type with myoepithelial anaplasia at recurrence after 10 years. We compared the histologic and cytologic findings of the initial and recurrent tumors. Aspiration cytology of the initial tumor was typical of classical EMC, represented by a biphasic pattern composed of sheetlike and tubular clusters. In contrast, cytologic specimens of the recurrent tumor, which had a focally biphasic pattern similar to that of the initial tumor, also had many isolated or discohesive piled-up clusters of spindle and polygonal cells with nuclear atypia. The cytologic findings of the recurrent tumor were consistent with a rare variant of EMC with myoepithelial anaplasia. To the best of our knowledge, this is the first report of the cytologic finding of an EMC with myoepithelial anaplasia.

  15. Elastic memory composites (EMC) for deployable industrial and commercial applications

    NASA Astrophysics Data System (ADS)

    Arzberger, Steven C.; Tupper, Michael L.; Lake, Mark S.; Barrett, Rory; Mallick, Kaushik; Hazelton, Craig; Francis, William; Keller, Phillip N.; Campbell, Douglas; Feucht, Sara; Codell, Dana; Wintergerst, Joe; Adams, Larry; Mallioux, Joe; Denis, Rob; White, Karen; Long, Mark; Munshi, Naseem A.; Gall, Ken

    2005-05-01

    The use of smart materials and multifunctional components has the potential to provide enhanced performance, improved economics, and reduced safety concerns for applications ranging from outer space to subterranean. Elastic Memory Composite (EMC) materials, based on shape memory polymers and used to produce multifunctional components and structures, are being developed and qualified for commercial use as deployable components and structures. EMC materials are similar to traditional fiber-reinforced composites except for the use of a thermoset shape memory resin that enables much higher packaging strains than traditional composites without damage to the fibers or the resin. This unique capability is being exploited in the development of very efficient EMC structural components for deployable spacecraft systems as well as capability enhancing components for use in other industries. The present paper is intended primarily to describe the transition of EMC materials as smart structure technologies into viable industrial and commercial products. Specifically, the paper discusses: 1) TEMBO EMC materials for deployable space/aerospace systems, 2) TEMBO EMC resins for terrestrial applications, 3) future generation EMC materials.

  16. Efficient Replication of the Novel Human Betacoronavirus EMC on Primary Human Epithelium Highlights Its Zoonotic Potential

    PubMed Central

    Kindler, Eveline; Jónsdóttir, Hulda R.; Muth, Doreen; Hamming, Ole J.; Hartmann, Rune; Rodriguez, Regulo; Geffers, Robert; Fouchier, Ron A. M.; Drosten, Christian; Müller, Marcel A.; Dijkman, Ronald; Thiel, Volker

    2013-01-01

    ABSTRACT The recent emergence of a novel human coronavirus (HCoV-EMC) in the Middle East raised considerable concerns, as it is associated with severe acute pneumonia, renal failure, and fatal outcome and thus resembles the clinical presentation of severe acute respiratory syndrome (SARS) observed in 2002 and 2003. Like SARS-CoV, HCoV-EMC is of zoonotic origin and closely related to bat coronaviruses. The human airway epithelium (HAE) represents the entry point and primary target tissue for respiratory viruses and is highly relevant for assessing the zoonotic potential of emerging respiratory viruses, such as HCoV-EMC. Here, we show that pseudostratified HAE cultures derived from different donors are highly permissive to HCoV-EMC infection, and by using reverse transcription (RT)-PCR and RNAseq data, we experimentally determined the identity of seven HCoV-EMC subgenomic mRNAs. Although the HAE cells were readily responsive to type I and type III interferon (IFN), we observed neither a pronounced inflammatory cytokine nor any detectable IFN responses following HCoV-EMC, SARS-CoV, or HCoV-229E infection, suggesting that innate immune evasion mechanisms and putative IFN antagonists of HCoV-EMC are operational in the new host. Importantly, however, we demonstrate that both type I and type III IFN can efficiently reduce HCoV-EMC replication in HAE cultures, providing a possible treatment option in cases of suspected HCoV-EMC infection. PMID:23422412

  17. Advanced Stirling Convertor Durability Testing: Plans and Interim Results

    NASA Technical Reports Server (NTRS)

    Meer, David W.; Oriti, Salvatore M.

    2012-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. In support of this program, GRC has been involved in testing Stirling convertors, including the Advanced Stirling Convertor (ASC), for use in the ASRG. This testing includes electromagnetic interference/compatibility (EMI/EMC), structural dynamics, advanced materials, organics, and unattended extended operation. The purpose of the durability tests is to experimentally demonstrate the margins in the ASC design. Due to the high value of the hardware, previous ASC tests focused on establishing baseline performance of the convertors within the nominal operating conditions. The durability tests present the first planned extension of the operating conditions into regions beyond those intended to meet the product spec, where the possibility exists of lateral contact, overstroke, or over-temperature events. These tests are not intended to cause damage that would shorten the life of the convertors, so they can transition into extended operation at the conclusion of the tests. This paper describes the four tests included in the durability test sequence: 1) start/stop cycling, 2) exposure to constant acceleration in the lateral and axial directions, 3) random vibration at increased piston amplitude to induce contact events, and 4) overstroke testing to simulate potential failures during processing or during the mission life where contact events could occur. The paper also summarizes the analysis and simulation used to predict the results of each of these tests.

  18. Management of the JWST MIRI pFM environmental and performance verification test campaign

    NASA Astrophysics Data System (ADS)

    Eccleston, Paul; Glasse, Alistair; Grundy, Timothy; Detre, Örs Hunor; O'Sullivan, Brian; Shaughnessy, Bryan; Sykes, Jon; Thatcher, John; Walker, Helen; Wells, Martyn; Wright, Gillian; Wright, David

    2012-09-01

    The Mid-Infrared Instrument (MIRI) is one of four scientific instruments on the James Webb Space Telescope (JWST) observatory, scheduled for launch in 2018. It will provide unique capabilities to probe the distant or deeply dust-enshrouded regions of the Universe, investigating the history of star and planet formation from the earliest universe to the present day. To enable this the instrument optical module must be cooled below 7K, presenting specific challenges for the environmental testing and calibration activities. The assembly, integration and verification (AIV) activities for the proto-flight model (pFM) instrument ran from March 2010 to May 2012 at RAL where the instrument has been put through a full suite of environmental and performance tests with a non-conventional single cryo-test approach. In this paper we present an overview of the testing conducted on the MIRI pFM including ambient alignment testing, vibration testing, gravity release testing, cryogenic performance and calibration testing, functional testing at ambient and operational temperatures, thermal balance tests, and Electro-Magnetic Compatibility (EMC) testing. We discuss how tests were planned and managed to ensure that the whole AIV process remained on schedule and give an insight into the lessons learned from this process. We also show how the process of requirement verification for this complex system was managed and documented. We describe how the risks associated with a single long duration test at operating temperature were controlled so that the complete suite of environmental tests could be used to build up a full picture of instrument compliance.

  19. Progress in the Development of the Lead Tungstate Crystals for EM-Calorimetry in High-Energy Physics

    NASA Astrophysics Data System (ADS)

    Novotny, R. W.; Brinkmann, K.-T.; Borisevich, A.; Dormenev, V.; Houzvicka, J.; Korjik, M.; Zaunick, H.-G.

    2017-11-01

    Even at present time there is a strong interest and demand for high quality lead tungstate crystals (PbWO4, PWO) for electromagnetic (EM) calorimetry. PWO is implemented into the EM calorimeter of the CMS-ECAL detector at LHC [1] and required for the completion of the PANDA EMC [2] and various ongoing detector projects at Jefferson Lab. The successful mass production of PWO using the Czochralski method was stopped after bankruptcy of the Bogoroditsk Technical Chemical Plant (BTCP) in Russia as major producer so far. The Shanghai Institute of Ceramics, Chinese Academy of Science (China) was considered as an alternative producer using the modified Bridgman method. The company CRYTUR (Turnov, Czech Republic) with good experience in the development and production of different types of inorganic oxide crystals has restarted at the end of 2014 the development of lead tungstate for mass production based on the Czochralski method. An impressive progress was achieved since then. The growing technology was optimized to produce full size samples with the quality meeting the PANDA-EMC specifications for PWO-II. We will present a detailed progress report on the research program in collaboration with groups at Orsay and JLab. The full size crystals will be characterized with respect to optical performance, light yield, kinetics and radiation hardness.

  20. Intrasystem Analysis Program (IAP) code summaries

    NASA Astrophysics Data System (ADS)

    Dobmeier, J. J.; Drozd, A. L. S.; Surace, J. A.

    1983-05-01

    This report contains detailed descriptions and capabilities of the codes that comprise the Intrasystem Analysis Program. The four codes are: Intrasystem Electromagnetic Compatibility Analysis Program (IEMCAP), General Electromagnetic Model for the Analysis of Complex Systems (GEMACS), Nonlinear Circuit Analysis Program (NCAP), and Wire Coupling Prediction Models (WIRE). IEMCAP is used for computer-aided evaluation of electromagnetic compatibility (ECM) at all stages of an Air Force system's life cycle, applicable to aircraft, space/missile, and ground-based systems. GEMACS utilizes a Method of Moments (MOM) formalism with the Electric Field Integral Equation (EFIE) for the solution of electromagnetic radiation and scattering problems. The code employs both full matrix decomposition and Banded Matrix Iteration solution techniques and is expressly designed for large problems. NCAP is a circuit analysis code which uses the Volterra approach to solve for the transfer functions and node voltage of weakly nonlinear circuits. The Wire Programs deal with the Application of Multiconductor Transmission Line Theory to the Prediction of Cable Coupling for specific classes of problems.

  1. Electromagnetic interference assessment of an ion drive electric propulsion system

    NASA Technical Reports Server (NTRS)

    Whittlesey, A. C.

    1979-01-01

    The electromagnetic interference (EMI) form elements of an ion drive electric propulsion system was analyzed, and the effects of EMI interaction with a typical interplanetary spacecraft engineering and scientific subsystems were predicted. SEMCAP, a computerized electromagnetic compatibility assessment code, was used to analyze the impact of EMI noise sources on 65 engineering/telemetry circuits and 48 plasma wave and planetary radio astronomy channels measuring over the range of 100 Hz to 40 MHz in a spacecraft of the Voyager type; manual methods were used to evaluate electrostatics, magnetics, and communications effects. Results indicate that some conducted and radiated spectra are in excess of electromagnetic compatibility specification limits; direct design changes may be required for filtering and shielding of thrust system elements. The worst source of broadband radiated noise appears to be the power processor. The magnetic field necessary to thruster operation is equivalent to about 18 amp-sq m per amp of beam current at right angles to the axis caused by the neutralizer/plume loop.

  2. On magnetoelectric coupling at equilibrium in continua with microstructure

    NASA Astrophysics Data System (ADS)

    Romeo, Maurizio

    2017-10-01

    A theory of micromorphic continua, applied to electromagnetic solids, is exploited to study magnetoelectric effects at equilibrium. Microcurrents are modeled by the microgyration tensor of stationary micromotions, compatibly with the balance equations for null microdeformation. The equilibrium of the continuum subject to electric and magnetic fields is reformulated accounting for electric multipoles which are related to microdeformation by evolution equations. Polarization and magnetization are derived for uniform fields under the micropolar reduction in terms of microstrain and octupole structural parameters. Nonlinear dependance on the electromagnetic fields is evidenced, compatibly with known theoretical and experimental results on magnetoelectric coupling.

  3. Moisture content of wood for interior use...Douglas-fir and robusta eucalyptus samples studied

    Treesearch

    R. Sidney Boone

    1967-01-01

    Panels of Douglas-fir and robusta eucalyptus blocks showed little seasonal variation in Equilibrium Moisture Content (EMC) of wood at 19 indoor locations on Oahu, Hawaii. Differences in EMC between locations were more variable. Minimum EMC at nonair-conditioned locations was 10 percent;at air-conditioned locations. 8 percent. Maximum EMC at nonairconditioned locations...

  4. Design of portable electric and magnetic field generators

    NASA Astrophysics Data System (ADS)

    Stewart, M. G.; Siew, W. H.; Campbell, L. C.; Stewart, M. G.; Siew, W. H.

    2000-11-01

    Electric and magnetic field generators capable of producing high-amplitude output are not readily available. This presents difficulties for electromagnetic compatibility testing of new measurement systems where these systems are intended to operate in a particularly hostile electromagnetic environment. A portable electric and a portable magnetic field generator having high pulsed field output are described in this paper. The output of these generators were determined using an electromagnetic-compatible measurement system. These generators allow immunity testing in the laboratory of electronic systems to very high electrical fields, as well as for functional verification of the electronic systems on site. In the longer term, the basic design of the magnetic field generator may be developed as the generator to provide the damped sinusoid magnetic field specified in IEC 61000-4-10, which is adopted in BS EN 61000-4-10.

  5. Avionics System Design for High Energy Fields

    DTIC Science & Technology

    1988-07-01

    this report describes design practices which will lead to reducc electromagnetic susceptibility of avionics systems in high energy fields . A second...nuclear reactions. Tn most cases the radiation which causes electromagnetic interference Is completely harmless to humans . Many techniqteq are used in...variety of electromagnetic compatibility problems. 1,e fIrst use EMCad to preeict the field strength from a discharge. Next, we usc’e r. a second

  6. Next generation sequencing of extraskeletal myxoid chondrosarcoma.

    PubMed

    Davis, Elizabeth J; Wu, Yi-Mi; Robinson, Dan; Schuetze, Scott M; Baker, Laurence H; Athanikar, Jyoti; Cao, Xuhong; Kunju, Lakshmi P; Chinnaiyan, Arul M; Chugh, Rashmi

    2017-03-28

    Extraskeletal myxoid chondrosarcoma (EMC) is an indolent translocation-associated soft tissue sarcoma with a high propensity for metastases. Using a clinical sequencing approach, we genomically profiled patients with metastatic EMC to elucidate the molecular biology and identify potentially actionable mutations. We also evaluated potential predictive factors of benefit to sunitinib, a multi-targeted tyrosine kinase inhibitor with reported activity in a subset of EMC patients. Between January 31, 2012 and April 15, 2016, six patients with EMC participated in the clinical sequencing research study. High quality DNA and RNA was isolated and matched normal samples underwent comprehensive next generation sequencing (whole or OncoSeq capture exome of tumor and normal, tumor PolyA+ and capture transcriptome). The expression levels of sunitinib targeted-kinases were measured by transcriptome sequencing for KDR, PDGFRA/B, KIT, RET, FLT1, and FLT4. The previously reported EWSR1-NR4A3 translocation was identified in all patient tumors; however, other recurring genomic abnormalities were not detected. RET expression was significantly greater in patients with EMC relative to other types of sarcomas except for liposarcoma (p<0.0002). The folate receptor was overexpressed in two patients. Our study demonstrated that similar to other translocation-associated sarcomas, the mutational profile of metastatic EMC is limited beyond the pathognomonic translocation. The clinical significance of RET expression in EMC should be explored. Additional pre-clinical investigations of EMC may help elucidate molecular mechanisms contributing to EMC tumorigenesis that could be translated to the clinical setting.

  7. Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.

    PubMed

    Yu, Ningbo; Gassert, Roger; Riener, Robert

    2011-07-01

    Robotic and mechatronic devices that work compatibly with magnetic resonance imaging (MRI) are applied in diagnostic MRI, image-guided surgery, neurorehabilitation and neuroscience. MRI-compatible mechatronic systems must address the challenges imposed by the scanner's electromagnetic fields. We have developed objective quantitative evaluation criteria for device characteristics needed to formulate design guidelines that ensure MRI-compatibility based on safety, device functionality and image quality. The mutual interferences between an MRI system and mechatronic devices working in its vicinity are modeled and tested. For each interference, the involved components are listed, and a numerical measure for "MRI-compatibility" is proposed. These interferences are categorized into an MRI-compatibility matrix, with each element representing possible interactions between one part of the mechatronic system and one component of the electromagnetic fields. Based on this formulation, design principles for MRI-compatible mechatronic systems are proposed. Furthermore, test methods are developed to examine whether a mechatronic device indeed works without interferences within an MRI system. Finally, the proposed MRI-compatibility criteria and design guidelines have been applied to an actual design process that has been validated by the test procedures. Objective and quantitative MRI-compatibility measures for mechatronic and robotic devices have been established. Applying the proposed design principles, potential problems in safety, device functionality and image quality can be considered in the design phase to ensure that the mechatronic system will fulfill the MRI-compatibility criteria. New guidelines and test procedures for MRI instrument compatibility provide a rational basis for design and evaluation of mechatronic devices in various MRI applications. Designers can apply these criteria and use the tests, so that MRI-compatibility results can accrue to build an experiential database.

  8. [Stimulation of mouse encephalomyocarditis virus reproduction by non-multiplying poliomyelitis virus in several transplantable tissue culture lines].

    PubMed

    Maslova, S V; Shirman, G A; Gavrilovskaia, I N

    1977-01-01

    Reproduction of mouse encephalomyocarditis virus (EMC) was studied in 5 continuous primate cell lines: HeLa, Fl, Detroit-6, P/7, and MIO inoculated with guanidine-dependent variant of poliomyelitis virus in the absence of guanidine. Poliomyelitis virus stimulated EMC virus reproduction in all cell lines under study. This stimulation effect was studied at length in HeLa and MIO cells. In HeLa cells, stimulation was observed at a low and moderate multiplicity of infection of EMC virus but not at a high (100 PEU/cell) multiplicity. Also, when EMC virus reproduction was stimulated, a shortening of the latent period of its multiplication cycle, an increase in the number of antigen-containing cells and the number of infectious centers were observed. In MIO cells, stimulation was found to occur both with low and high doses of EMC virus but not to be accompanied by a shortening in the latent period of EMC reproduction cycle, or any increase in the antigen-containing cells or number of infectious centers. In both cell types upon mixed infection the synthesis of virus-specific RNA's of EMC virus was enhanced. It is suggested that the stimulating effect of poliomyelitis virus is realized in HeLa and MIO cells at different stages of EMC virus reproduction.

  9. Encapsulation of ethylhexyl methoxycinnamate, a light-sensitive UV filter, in lipid nanoparticles.

    PubMed

    Durand, L; Habran, N; Henschel, V; Amighi, K

    2010-01-01

    The aim of this study was to encapsulate ethylhexyl methoxycinnamate (EMC), a commonly used UVB filter, in a solid lipid matrix in order to obtain microparticles and then nanoparticles to reduce its photo-instability under UV light exposure. Glyceryl behenate, rice bran wax and ozokerite were investigated for encapsulating EMC. The suspensions of nanoparticles contained 70% encapsulated EMC (relative to the lipid mass). The absorbance level at 310 nm of suspensions containing nanoparticles was more than twice that of those containing microparticles. So, decreasing the size of particles improved the efficiency of light protection, regardless of the lipid material used. Moreover, free EMC presented a 30% loss of its efficiency after 2 h of irradiation, whereas the three NLC formulations showed a loss of absorbency between 10% and 21%. The in vitro cutaneous penetration test did not show a higher potential penetration for EMC contained in nanosuspensions compared to free EMC.

  10. Micro-patterning of resin-bonded NdFeB magnet for a fully integrated electromagnetic actuator

    NASA Astrophysics Data System (ADS)

    Tao, Kai; Wu, Jin; Kottapalli, Ajay Giri Prakash; Chen, Di; Yang, Zhuoqing; Ding, Guifu; Lye, Sun Woh; Miao, Jianmin

    2017-12-01

    This paper reports a fully-integrated, batch-fabricated electromagnetic actuator which features micro-patterned NdFeB magnets. The entire actuator is fabricated through MEMS-compatible laminated surface micromachining technology, eliminating the requirement for further component assembly processes. The fabrication strategy allowed the entire volume of the actuator to be reduced to a small size of 2.5 × 2.5 × 2 mm3, which is one of the smallest NdFeB-based electromagnetic actuators demonstrated to date. The magnetic properties of NdFeB thin films are further investigated and optimized using different types of lithographically-defined micromolds. By altering the direction of the input current, actuating displacements of approximately ±10 μm are achieved during both the attraction and the repulsion operations. This work demonstrates the viability and compatibility of using polymer-bonded magnets for magnetic MEMS applications.

  11. Military applications of emission and susceptibility data

    NASA Astrophysics Data System (ADS)

    Kohlbacher, Howard; Walker, William

    A basic design consideration for new military communications-electronics (C-E) equipment is that it be electromagnetically compatible with the environment in which it will operate. A military standard (MIL-STD-461B) describes the design requirements for the control of the unintentional electromagnetic emission and susceptibility characteristics of electronic equipment and subsystems designed or procured by the US Department of Defense. For new systems which fail the test standards of MIL-STD-461B with regard to radiated susceptibility (RSO3) or radiated emissions (RE02), a decision must be made to fix the new system or to field it without a fix. A procedure to aid in the decision process is outlined. The minimum separation distances required between a failed test system and other C-E equipment in its environment to avoid interference are determined. If this distance is operationally acceptable, the failed unit may be considered to be operationally compatible with its electromagnetic environment.

  12. Cross-reactive antibodies in convalescent SARS patients' sera against the emerging novel human coronavirus EMC (2012) by both immunofluorescent and neutralizing antibody tests.

    PubMed

    Chan, Kwok-Hung; Chan, Jasper Fuk-Woo; Tse, Herman; Chen, Honglin; Lau, Candy Choi-Yi; Cai, Jian-Piao; Tsang, Alan Ka-Lun; Xiao, Xincai; To, Kelvin Kai-Wang; Lau, Susanna Kar-Pui; Woo, Patrick Chiu-Yat; Zheng, Bo-Jiang; Wang, Ming; Yuen, Kwok-Yung

    2013-08-01

    A severe acute respiratory syndrome (SARS)-like disease due to a novel betacoronavirus, human coronavirus EMC (HCoV-EMC), has emerged recently. HCoV-EMC is phylogenetically closely related to Tylonycteris-bat-coronavirus-HKU4 and Pipistrellus-bat-coronavirus-HKU5 in Hong Kong. We conducted a seroprevalence study on archived sera from 94 game-food animal handlers at a wild life market, 28 SARS patients, and 152 healthy blood donors in Southern China to assess the zoonotic potential and evidence for intrusion of HCoV-EMC and related viruses into humans. Anti-HCoV-EMC and anti-SARS-CoV antibodies were detected using screening indirect immunofluorescence (IF) and confirmatory neutralizing antibody tests. Two (2.1%) animal handlers had IF antibody titer of ≥ 1:20 against both HCoV-EMC and SARS-CoV with neutralizing antibody titer of <1:10. No blood donor had antibody against either virus. Surprisingly, 17/28 (60.7%) of SARS patients had significant IF antibody titers with 7/28 (25%) having anti-HCoV-EMC neutralizing antibodies at low titers which significantly correlated with that of HCoV-OC43. Bioinformatics analysis demonstrated a significant B-cell epitope overlapping the heptad repeat-2 region of Spike protein. Virulence of SARS-CoV over other betacoronaviruses may boost cross-reactive neutralizing antibodies against other betacoronaviruses. Convalescent SARS sera may contain cross-reactive antibodies against other betacoronaviruses and confound seroprevalence study for HCoV-EMC. Copyright © 2013 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  13. Achieving EMC Emissions Compliance for an Aeronautics Power Line Communications System

    NASA Astrophysics Data System (ADS)

    Dominiak, S.; Vos, G.; ter Meer, T.; Widmer, H.

    2012-05-01

    Transmitting data over the power distribution network - Power Line Communications (PLC) -provides an interesting solution to reducing the weight and complexity of wiring networks in commercial aircraft. One of the potential roadblocks for the introduction of this technology is achieving EMC emissions compliance. In this article an overview of the EMC conducted and radiated emissions testing for PLC- enabled aeronautics equipment is presented. Anomalies resulting from chamber resonances leading to discrepancies between the conducted emissions tests and the measured radiated emissions are identified and described. Measurements made according to the current version of the civil aeronautical EMC standard, EUROCAE ED-14F (RTCA DO-160F), show that PLC equipment can achieve full EMC emissions compliance.

  14. Electronic media communication with friends from 2002 to 2006 and links to face-to-face contacts in adolescence: an HBSC study in 31 European and North American countries and regions.

    PubMed

    Kuntsche, Emmanuel; Simons-Morton, Bruce; ter Bogt, Tom; Queija, Inmaculada Sánchez; Tinoco, Victoria Muñoz; Gaspar de Matos, Margarida; Santinello, Massimo; Lenzi, Michela

    2009-09-01

    Because the potential for electronic media communication (EMC) has increased greatly, it is of interest to describe trends in EMC between adolescents and their friends and to investigate whether EMC facilitate or supersede face-to-face contacts among peers. Answers of 275,571 adolescents concerning contacting friends by means of the phone, text messages, and the internet (i. e. EMC), the number of close friends, and the number of afternoons and evenings per week spent out with friends were analysed by means of chi(2)-tests and multiple regression. In 2006, between more than one third (11-year olds) and nearly two thirds (15-year olds) communicated electronically with their friends daily or nearly daily. From 2002 to 2006, EMC increased in almost all participating countries. Particularly high increases were found in Eastern Europe. Across countries, the higher the frequency of EMC the higher the number of afternoons and evenings spent with friends. The results are surprisingly consistent across the 31 countries and suggest that EMC among adolescents facilitate rather than supersede face-to-face peer contacts.

  15. Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview

    PubMed Central

    Taffoni, Fabrizio; Formica, Domenico; Saccomandi, Paola; Di Pino, Giovanni; Schena, Emiliano

    2013-01-01

    During last decades, Magnetic Resonance (MR)—compatible sensors based on different techniques have been developed due to growing demand for application in medicine. There are several technological solutions to design MR-compatible sensors, among them, the one based on optical fibers presents several attractive features. The high elasticity and small size allow designing miniaturized fiber optic sensors (FOS) with metrological characteristics (e.g., accuracy, sensitivity, zero drift, and frequency response) adequate for most common medical applications; the immunity from electromagnetic interference and the absence of electrical connection to the patient make FOS suitable to be used in high electromagnetic field and intrinsically safer than conventional technologies. These two features further heightened the potential role of FOS in medicine making them especially attractive for application in MRI. This paper provides an overview of MR-compatible FOS, focusing on the sensors employed for measuring physical parameters in medicine (i.e., temperature, force, torque, strain, and position). The working principles of the most promising FOS are reviewed in terms of their relevant advantages and disadvantages, together with their applications in medicine. PMID:24145918

  16. Evaluation of a Commercially Available Single Building EMCS (Energy Monitoring Control System).

    DTIC Science & Technology

    1985-02-01

    Available Single Building EMCS K i,,n vir Sanchey. John Franchi and Karlin Canfield S -,or isored by Naval Material Cor it iand February. 1985 LU...BUILDING EMCS (SBEMCS), (Final) by Ivan Sanchez and John Franchi TR-914 29 pp illus February 1985 Unclassified 1. EMCS 2. Energy conservation I. Z0371-O1...Ivan Sanchez, John Franchi and Karlin Canfield 9 PERFORMING ORGANIZAT.ON NAME AND ADDRESS 𔃺 PROGRAM ELEMENT PROJECT, TASKAREA & WORK UNIIT NUMBERS

  17. EMC effect in the Drell-Yan process at COMPASS

    NASA Astrophysics Data System (ADS)

    Mitrofanov, Evgenii

    2018-04-01

    The EMC effect or a modification of parton distributions in bound nucleons as compared to free ones, has been extensively studied during the last 30 years but its full understanding is still lacking. The COMPASS experiment at CERN will provide new results on the EMC effect, originating from the Drell-Yan process and studied in the 190 GeV=c π- beam scattering on the ammonia and tungsten targets. The present understanding of the EMC effect and experimental possibilities of COMPASS in this context are discussed.

  18. Theoretical Basis for Anomalous Heat and ^4He in Deuterium-Metal Systems

    NASA Astrophysics Data System (ADS)

    Chubb, Scott; Chubb, Talbot

    2000-03-01

    Because electromagnetic (E.M.) forces have infinite range, reactions exist in which the degrees of freedom associated with nuclear- and atomic- scales are coupled. Although such non-separable reactions are possible in conventional D+D fusion, they rarely occur because the relevant E.M.-induced reaction (D+Darrow ^4He) violates the rules of energy-momentum conservation (EMC) at-a-point, except when a high momentum (HM) gamma ray is emitted. When D^+ and ^4He^+^+ occupy ion band states with low concentration, however, different forms of E.M. coupling become possible in which EMC is violated locally but conserved globally and D+Darrow ^4He reactions occur without HM particles(http: //www.aps.org/meet/CENT99/BAPS/abs/S9500.html). Using a generalized KKR-Multiple-Scattering theory, we have formulated Generalized Kadanoff-Baym Equations ( D.C. Langreth and J.W. Wilkins, Phys. Rev. B 6), 3189 (1972). that describe the associated non-local heat and ^4He release from the resulting coupling between nuclear interactions, D^+ and ^4He^+^+ ion band states, and electrons.

  19. National Centers for Environmental Prediction

    Science.gov Websites

    Organization Search Enter text Search Navigation Bar End Cap Search EMC Go Branches Global Climate and Weather / VISION | About EMC EMC > GLOBAL BRANCH > GFS > HOME Home Implementations Documentation References Products Model Guidance Performance Developers VLab GLOBAL FORECAST SYSTEM Global Data

  20. Enamel microcracks in terms of orthodontic treatment: A novel method for their detection and evaluation.

    PubMed

    Dumbryte, Irma; Linkeviciene, Laura; Linkevicius, Tomas; Malinauskas, Mangirdas

    2017-07-26

    The study aimed at introducing current available techniques for enamel microcracks (EMCs) detection, and presenting a method for direct quantitative analysis of an individual EMC. Measurements of the detailed EMCs characteristics (location, length, and width) were taken from the reconstructed images of the buccal tooth surface (teeth extracted from two age groups of patients) employing a scanning electron microscopy (SEM) and our derived formulas before and after ceramic brackets removal. Measured parameters of EMCs for younger age group were 2.41 µm (width), 3.68 mm (length) before and 2.73 µm, 3.90 mm after debonding; for older -4.03 µm, 4.35 mm before and 4.80 µm, 4.37 mm after brackets removal. Following debonding EMCs increased for both groups, however the changes in width and length were statistically insignificant. Regardless of the age group, proposed method enabled precise detection of the same EMC before and after debonding, and quantitative examination of its characteristics.

  1. Primary extraskeletal myxoid chondrosarcoma of the vulva.

    PubMed

    Sawada, Morio; Tochigi, Naobumi; Sasajima, Yuko; Hasegawa, Tadashi; Kasamatsu, Takahiro; Kitawaki, Jo

    2011-11-01

    Primary extraskeletal myxoid chondrosarcoma (EMC) of the vulva is extremely rare. There is little available information about the biological behavior and treatment strategy for primary EMC of the vulva. We report a rare case of primary EMC of the vulva treated surgically. A 24-year-old Japanese woman had demonstrated a small and elastic mass of the vulva and underwent enucleation of the mass at a previous hospital, but a definitive histopathological diagnosis was not obtained. Therefore, the patient was referred to our hospital for further evaluation and treatment. We histopathologically diagnosed the tumor as primary EMC of the vulva and performed vulvectomy with vulvoperineal reconstruction. Microscopic examination of the resected specimens demonstrated residual tumor nodules of EMC. However, there were no viable tumor cells at the surgical margin. Approximately two years after wide local excision was performed, the patient is doing well and there is no apparent recurrence of EMC. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.

  2. Detection and Tracking of Moving Targets Behind Cluttered Environments Using Compressive Sensing

    NASA Astrophysics Data System (ADS)

    Dang, Vinh Quang

    Detection and tracking of moving targets (target's motion, vibration, etc.) in cluttered environments have been receiving much attention in numerous applications, such as disaster search-and-rescue, law enforcement, urban warfare, etc. One of the popular techniques is the use of stepped frequency continuous wave radar due to its low cost and complexity. However, the stepped frequency radar suffers from long data acquisition time. This dissertation focuses on detection and tracking of moving targets and vibration rates of stationary targets behind cluttered medium such as wall using stepped frequency radar enhanced by compressive sensing. The application of compressive sensing enables the reconstruction of the target space using fewer random frequencies, which decreases the acquisition time. Hardware-accelerated parallelization on GPU is investigated for the Orthogonal Matching Pursuit reconstruction algorithm. For simulation purpose, two hybrid methods have been developed to calculate the scattered fields from the targets through the wall approaching the antenna system, and to convert the incoming fields into voltage signals at terminals of the receive antenna. The first method is developed based on the plane wave spectrum approach for calculating the scattered fields of targets behind the wall. The method uses Fast Multiple Method (FMM) to calculate scattered fields on a particular source plane, decomposes them into plane wave components, and propagates the plane wave spectrum through the wall by integrating wall transmission coefficients before constructing the fields on a desired observation plane. The second method allows one to calculate the complex output voltage at terminals of a receiving antenna which fully takes into account the antenna effects. This method adopts the concept of complex antenna factor in Electromagnetic Compatibility (EMC) community for its calculation.

  3. RHETT2/EPDM Hall Thruster Propulsion System Electromagnetic Compatibility Evaluation

    NASA Technical Reports Server (NTRS)

    Sarmiento, Charles J.; Sankovic, John M.; Freitas, Joseph; Lynn, Peter R.

    1997-01-01

    Electromagnetic compatibility measurements were obtained as part of the Electric Propulsion Demonstration Module (EPDM) flight qualification program. Tests were conducted on a Hall thruster system operating at a nominal 66O W discharge power. Measurements of conducted and radiated susceptibility and emissions were obtained and referenced to MEL-STD-461 C. The power processor showed some conducted susceptibility below 4 kHz for the magnet current and discharge voltage. Radiated susceptibility testing yielded a null result. Conducted emissions showed slight violations of the specified limit for MIL-461C CE03. Radiated emissions exceeded the RE02 standard at low frequencies, below 300 MHz, by up to 40 dB RV/m/MHz.

  4. Measurement of the EMC effect in the deuteron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Griffioen, Keith A.; Arrington, John R.; Christy, M. Eric

    2015-07-21

    We have determined the structure function ratiomore » $$R^d_{\\rm EMC}=F_2^d/(F_2^n+F_2^p)$$ from recently published $$F_2^n/F_2^d$$ data taken by the BONuS experiment using CLAS at Jefferson Lab. This ratio deviates from unity, with a slope $$dR_{\\rm EMC}^{d}/dx= -0.10\\pm 0.05$$ in the range of Bjorken $x$ from 0.35 to 0.7, for invariant mass $W>1.4$ GeV and $Q^2>1$ GeV$^2$. The observed EMC effect for these kinematics is consistent with conventional nuclear physics models that include off-shell corrections, as well as with empirical analyses that find the EMC effect proportional to the probability of short-range nucleon-nucleon correlations.« less

  5. Cell host response to infection with novel human coronavirus EMC predicts potential antivirals and important differences with SARS coronavirus.

    PubMed

    Josset, Laurence; Menachery, Vineet D; Gralinski, Lisa E; Agnihothram, Sudhakar; Sova, Pavel; Carter, Victoria S; Yount, Boyd L; Graham, Rachel L; Baric, Ralph S; Katze, Michael G

    2013-04-30

    A novel human coronavirus (HCoV-EMC) was recently identified in the Middle East as the causative agent of a severe acute respiratory syndrome (SARS) resembling the illness caused by SARS coronavirus (SARS-CoV). Although derived from the CoV family, the two viruses are genetically distinct and do not use the same receptor. Here, we investigated whether HCoV-EMC and SARS-CoV induce similar or distinct host responses after infection of a human lung epithelial cell line. HCoV-EMC was able to replicate as efficiently as SARS-CoV in Calu-3 cells and similarly induced minimal transcriptomic changes before 12 h postinfection. Later in infection, HCoV-EMC induced a massive dysregulation of the host transcriptome, to a much greater extent than SARS-CoV. Both viruses induced a similar activation of pattern recognition receptors and the interleukin 17 (IL-17) pathway, but HCoV-EMC specifically down-regulated the expression of several genes within the antigen presentation pathway, including both type I and II major histocompatibility complex (MHC) genes. This could have an important impact on the ability of the host to mount an adaptive host response. A unique set of 207 genes was dysregulated early and permanently throughout infection with HCoV-EMC, and was used in a computational screen to predict potential antiviral compounds, including kinase inhibitors and glucocorticoids. Overall, HCoV-EMC and SARS-CoV elicit distinct host gene expression responses, which might impact in vivo pathogenesis and could orient therapeutic strategies against that emergent virus. Identification of a novel coronavirus causing fatal respiratory infection in humans raises concerns about a possible widespread outbreak of severe respiratory infection similar to the one caused by SARS-CoV. Using a human lung epithelial cell line and global transcriptomic profiling, we identified differences in the host response between HCoV-EMC and SARS-CoV. This enables rapid assessment of viral properties and the ability to anticipate possible differences in human clinical responses to HCoV-EMC and SARS-CoV. We used this information to predict potential effective drugs against HCoV-EMC, a method that could be more generally used to identify candidate therapeutics in future disease outbreaks. These data will help to generate hypotheses and make rapid advancements in characterizing this new virus.

  6. Novel Methods for Electromagnetic Simulation and Design

    DTIC Science & Technology

    2016-08-03

    The resulting discretized integral equations are compatible with fast multipoleaccelerated solvers and will form the basis for high fidelity...expansion”) which are high-order, efficient and easy to use on arbitrarily triangulated surfaces. The resulting discretized integral equations are...created a user interface compatible with both low and high order discretizations , and implemented the generalized Debye approach of [4]. The

  7. An Attempt to Compare EMCS with TOXLINE.

    ERIC Educational Resources Information Center

    Lorent, Jean-Pierre; Schirner, Hedi

    1978-01-01

    Sixteen queries, performed on the two systems, resulted in 247 unique relevant references from EMCS and 559 from TOXLINE. The overlap varied considerably, from 6 to 50 percent. It is remarkable that TOXLINE, with nine subfiles specially compiled for toxicology, can be supplemented by EMCS, which in the present study delivered 31 percent of all the…

  8. Interactive color-graphics interface for energy-monitoring and -control systems. Final report, October 1979-September 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canfield, K.J.

    1984-05-01

    An EMCS (Energy Monitoring and Control System) can be described as a system that automatically takes care of routine operation of equipment and provides centralized reporting and override capabilities. Equipment controlled by an EMCS would be heating, ventilating, and air conditioning (HVAC) equipment, air compressors, and small package boiler units. The EMCS would obtain raw information (data) from sensors associated with the equipment and massage the data into useful information. The information obtained from the sensors plus additional information available to the EMCS would be used to control the equipment. The information would also be available to the operator inmore » the form of reports or in response to operator commands for specific information. EMCS are computerized systems that control and monitor energy consuming and producing equipment at Naval facilities. The larger systems have been installed with color-graphics cathode ray tube operator consoles to provide better information to the personnel operating these systems. This report summarizes the work done on defining an adequate operator console and recommends changes to the existing EMCS Guide Specifications.« less

  9. Effecting aging time of epoxy molding compound to molding process for integrated circuit packaging

    NASA Astrophysics Data System (ADS)

    Tachapitunsuk, Jirayu; Ugsornrat, Kessararat; Srisuwitthanon, Warayoot; Thonglor, Panakamon

    2017-09-01

    This research studied about effecting aging time of epoxy molding compound (EMC) that effect to reliability performance of integrated circuit (IC) package in molding process. Molding process is so important of IC packaging process for protecting IC chip (or die) from temperature and humidity environment using encapsulated EMC. For general molding process, EMC are stored in the frozen at 5°C and left at room temperature at 25 °C for aging time on self before molding of die onto lead frame is 24 hours. The aging time effect to reliability performance of IC package due to different temperature and humidity inside the package. In experiment, aging time of EMC were varied from 0 to 24 hours for molding process of SOIC-8L packages. For analysis, these packages were tested by x-ray and scanning acoustic microscope to analyze properties of EMC with an aging time and also analyzed delamination, internal void, and wire sweep inside the packages with different aging time. The results revealed that different aging time of EMC effect to properties and reliability performance of molding process.

  10. Novel device for creating continuous curvilinear capsulorhexis.

    PubMed

    Soylak, Mustafa

    2016-01-01

    The purpose of this paper is to develop a novel capsulorhexis system. Mechatronics Laboratory, University of Erciyes and Kayseri Maya Eye Hospital. A 3D model was created and simulations were conducted to develop a new device which was designed, fabricated and tested for continuous curvilinear capsulorhexis (CCC). The name of this system is the electro-mechanical capsulorhexis system (EMCS). The 3D model was created by using a commercial design software and a 3D printer was used to fabricate the EMCS Finite element analysis and geometrical relation tests of the EMCS for different sized lenses were performed. The results show that the EMCS is a perfect solution for capsulorhexis surgeries, without mechanical or geometrical problems. The EMCS can open the anterior lens capsule more easily and effectively than manual CCC applications and needs less experience.

  11. Intrasystem Electromagnetic Compatibility Analysis Program. Volume 2. User’s Manual Usage Section

    DTIC Science & Technology

    1974-12-01

    AD-A008 527 INTRASYSTEM ELECTROMAGNETIC COMPATI- BILITY ANALYSIS PROGRAM. VOLUME II.USER’S MANUAL USAGE SECTION J. L. Bogdanor , et al McDonnell...NUMBERVolume II - User’s Manual Usage Section None 7. AUTHOR(&) 8. CONTRACT OR GRANT NUMBER(s) J.L. Bogdanor F30602-72-C-0277 R.A. Pearlman M.D. Siegel

  12. International trends in electronic media communication among 11- to 15-year-olds in 30 countries from 2002 to 2010: association with ease of communication with friends of the opposite sex.

    PubMed

    Boniel-Nissim, Meyran; Lenzi, Michela; Zsiros, Emese; de Matos, Margarida Gaspar; Gommans, Rob; Harel-Fisch, Yossi; Djalovski, Amir; van der Sluijs, Winfried

    2015-04-01

    Electronic media has become a central part of the lives of adolescents. Therefore, this study examines trends in adolescent electronic media communication (EMC) and its relationship with ease of communication with friends of the opposite sex, from 2002 to 10 in 30 European and North American regions. Data from the HBSC study were collected using self-report questionnaires from 11-, 13- and 15-year-old participants (N = 404 523). EMC use has grown over the years in most of these regions and increases with age. Even though Internet usage is often blamed for its negative effects on teenagers' social interactions in the physical world, in this study EMC was found to predict ease of communication with friends. Especially, the more they use EMC, the easier they find it to talk with friends of the opposite sex. Although these findings suggest that EMC reinforces communication, the interaction between year (2002-2006-2010) and EMC usage was not significant. This finding contradicts research that suggests that EMC contributes to loneliness and isolation, and supports other studies that present electronic media as a powerful tool for helping to connect people. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  13. Electromagnetic compatibility and safety design of a patient compliance-free, inductive implant charger.

    PubMed

    Theodoridis, Michael P; Mollov, Stefan V

    2014-10-01

    This article presents the design of a domestic, radiofrequency induction charger for implants toward compliance with the Federal Communications Commission safety and electromagnetic compatibility regulations. The suggested arrangement does not impose any patient compliance requirements other than the use of a designated bed for night sleep, and therefore can find a domestic use. The method can be applied to a number of applications; a rechargeable pacemaker is considered as a case study. The presented work has proven that it is possible to realize a fully compliant inductive charging system with minimal patient interaction, and has generated important information for consideration by the designers of inductive charging systems. Experimental results have verified the validity of the theoretical findings.

  14. Hidden momentum and the Abraham-Minkowski debate

    NASA Astrophysics Data System (ADS)

    Saldanha, Pablo L.; Filho, J. S. Oliveira

    2017-04-01

    We use an extended version of electrodynamics, which admits the existence of magnetic charges and currents, to discuss how different models for electric and magnetic dipoles do or do not carry hidden momentum under the influence of external electromagnetic fields. Based on that, we discuss how the models adopted for the electric and magnetic dipoles from the particles that compose a material medium influence the expression for the electromagnetic part of the light momentum in the medium. We show that Abraham expression is compatible with electric dipoles formed by electric charges and magnetic dipoles formed by magnetic charges, while Minkowski expression is compatible with electric dipoles formed by magnetic currents and magnetic dipoles formed by electric currents. The expression ɛ0E ×B , on the other hand, is shown to be compatible with electric dipoles formed by electric charges and magnetic dipoles formed by electric currents, which are much more natural models. So this expression has an interesting interpretation in the Abraham-Minkowski debate about the momentum of light in a medium: It is the expression compatible with the nonexistence of magnetic charges. We also provide a simple justification of why Abraham and Minkowski momenta can be associated with the kinetic and canonical momentum of light, respectively.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Kee Sung; Rajput, Nav Nidhi; Persson, Kristin A.

    Ferrocene (Fc) and N-(ferrocenylmethyl)-N,N-dimethyl-N-ethylammonium bistrifluoromethyl-sulfonimide (Fc1N112-TFSI) were dissolved in carbonate solvents and self-diffusion coefficients (D) of solutes and solvents were measured by {sup 1}H and {sup 19}F pulsed field gradient nuclear magnetic resonance (NMR) spectroscopy. The organic solvents were propylene carbonate (PC), ethyl methyl carbonate (EMC), and a ternary mixture that also includes ethylene carbonate (EC). Results from NMR studies over the temperature range of 0–50 °C and for various concentrations (0.25–1.7 M) of Fc1N112-TFSI are compared to values of D simulated with classical molecular dynamics (MD). The measured self-diffusion coefficients gradually decreased as the Fc1N112-TFSI concentration increased in allmore » solvents. Since TFSI{sup −} has fluoromethyl groups (CF{sub 3}), D{sub TFSI} could be measured separately and the values found are larger than those for D{sub Fc1N112} in all samples measured. The EC, PC, and EMC have the same D in the neat solvent mixture and when Fc is dissolved in EC/PC/EMC at a concentration of 0.2 M, probably due to the interactions between common carbonyl structures within EC, PC, and EMC. A difference in D (D{sub PC} < D{sub EC} < D{sub EMC}), and both a higher E{sub a} for translational motion and higher effective viscosity for PC in the mixture containing Fc1N112-TFSI reflect the interaction between PC and Fc1N112{sup +}, which is a relatively stronger interaction than that between Fc1N112{sup +} and other solvent species. In the EC/PC/EMC solution that is saturated with Fc1N112-TFSI, we find that D{sub PC} = D{sub EC} = D{sub EMC} and Fc1N112{sup +} and all components of the EC/PC/EMC solution have the same E{sub a} for translational motion, while the ratio D{sub EC/PC/EMC}/D{sub Fc1N112} is approximately 3. These results reflect the lack of available free volume for independent diffusion in the saturated solution. The Fc1N112{sup +} transference numbers lie around 0.4 and increase slightly as the temperature is increased in the PC and EMC solvents. The trends observed for D from simulations are in good agreement with experimental results and provide molecular level understanding of the solvation structure of Fc1N112-TFSI dissolved in EC/PC/EMC.« less

  16. Flight Hardware Packaging Design for Stringent EMC Radiated Emission Requirements

    NASA Technical Reports Server (NTRS)

    Lortz, Charlene L.; Huang, Chi-Chien N.; Ravich, Joshua A.; Steiner, Carl N.

    2013-01-01

    This packaging design approach can help heritage hardware meet a flight project's stringent EMC radiated emissions requirement. The approach requires only minor modifications to a hardware's chassis and mainly concentrates on its connector interfaces. The solution is to raise the surface area where the connector is mounted by a few millimeters using a pedestal, and then wrapping with conductive tape from the cable backshell down to the surface-mounted connector. This design approach has been applied to JPL flight project subsystems. The EMC radiated emissions requirements for flight projects can vary from benign to mission critical. If the project's EMC requirements are stringent, the best approach to meet EMC requirements would be to design an EMC control program for the project early on and implement EMC design techniques starting with the circuit board layout. This is the ideal scenario for hardware that is built from scratch. Implementation of EMC radiated emissions mitigation techniques can mature as the design progresses, with minimal impact to the design cycle. The real challenge exists for hardware that is planned to be flown following a built-to-print approach, in which heritage hardware from a past project with a different set of requirements is expected to perform satisfactorily for a new project. With acceptance of heritage, the design would already be established (circuit board layout and components have already been pre-determined), and hence any radiated emissions mitigation techniques would only be applicable at the packaging level. The key is to take a heritage design with its known radiated emissions spectrum and repackage, or modify its chassis design so that it would have a better chance of meeting the new project s radiated emissions requirements.

  17. Cell Host Response to Infection with Novel Human Coronavirus EMC Predicts Potential Antivirals and Important Differences with SARS Coronavirus

    PubMed Central

    Josset, Laurence; Menachery, Vineet D.; Gralinski, Lisa E.; Agnihothram, Sudhakar; Sova, Pavel; Carter, Victoria S.; Yount, Boyd L.; Graham, Rachel L.; Baric, Ralph S.; Katze, Michael G.

    2013-01-01

    ABSTRACT A novel human coronavirus (HCoV-EMC) was recently identified in the Middle East as the causative agent of a severe acute respiratory syndrome (SARS) resembling the illness caused by SARS coronavirus (SARS-CoV). Although derived from the CoV family, the two viruses are genetically distinct and do not use the same receptor. Here, we investigated whether HCoV-EMC and SARS-CoV induce similar or distinct host responses after infection of a human lung epithelial cell line. HCoV-EMC was able to replicate as efficiently as SARS-CoV in Calu-3 cells and similarly induced minimal transcriptomic changes before 12 h postinfection. Later in infection, HCoV-EMC induced a massive dysregulation of the host transcriptome, to a much greater extent than SARS-CoV. Both viruses induced a similar activation of pattern recognition receptors and the interleukin 17 (IL-17) pathway, but HCoV-EMC specifically down-regulated the expression of several genes within the antigen presentation pathway, including both type I and II major histocompatibility complex (MHC) genes. This could have an important impact on the ability of the host to mount an adaptive host response. A unique set of 207 genes was dysregulated early and permanently throughout infection with HCoV-EMC, and was used in a computational screen to predict potential antiviral compounds, including kinase inhibitors and glucocorticoids. Overall, HCoV-EMC and SARS-CoV elicit distinct host gene expression responses, which might impact in vivo pathogenesis and could orient therapeutic strategies against that emergent virus. PMID:23631916

  18. Comparison of Commercial Electromagnetic Interface Test Techniques to NASA Electromagnetic Interference Test Techniques

    NASA Astrophysics Data System (ADS)

    Smith, V.

    2000-11-01

    This report documents the development of analytical techniques required for interpreting and comparing space systems electromagnetic interference test data with commercial electromagnetic interference test data using NASA Specification SSP 30237A "Space Systems Electromagnetic Emission and Susceptibility Requirements for Electromagnetic Compatibility." The PSpice computer simulation results and the laboratory measurements for the test setups under study compare well. The study results, however, indicate that the transfer function required to translate test results of one setup to another is highly dependent on cables and their actual layout in the test setup. Since cables are equipment specific and are not specified in the test standards, developing a transfer function that would cover all cable types (random, twisted, or coaxial), sizes (gauge number and length), and layouts (distance from the ground plane) is not practical.

  19. Comparison of Commercial Electromagnetic Interface Test Techniques to NASA Electromagnetic Interference Test Techniques

    NASA Technical Reports Server (NTRS)

    Smith, V.; Minor, J. L. (Technical Monitor)

    2000-01-01

    This report documents the development of analytical techniques required for interpreting and comparing space systems electromagnetic interference test data with commercial electromagnetic interference test data using NASA Specification SSP 30237A "Space Systems Electromagnetic Emission and Susceptibility Requirements for Electromagnetic Compatibility." The PSpice computer simulation results and the laboratory measurements for the test setups under study compare well. The study results, however, indicate that the transfer function required to translate test results of one setup to another is highly dependent on cables and their actual layout in the test setup. Since cables are equipment specific and are not specified in the test standards, developing a transfer function that would cover all cable types (random, twisted, or coaxial), sizes (gauge number and length), and layouts (distance from the ground plane) is not practical.

  20. Electromagnetic Compatibility in the Defense Systems of Future Years

    DTIC Science & Technology

    2002-06-01

    Technology activities. Its mission is to conduct and promote cooperative research and information exchange . The objective is to support the development...testing CLEARANCE PRODUCTION AND IN-SERVICE SUPPORT Modelling in support of conceptual design (structure & installation design) EMH Design guides for the... marketed by Advanced Electromagnetics [6-1]. Transmission Line Matrix Method The link between field theory and circuit theory, the major theories on

  1. National Centers for Environmental Prediction

    Science.gov Websites

    Skip Navigation Links www.nws.noaa.gov NOAA logo - Click to go to the NOAA homepage National Weather Service NWS logo - Click to go to the NWS homepage EMC Logo Navigation Bar Left Cap Home News Publications EMC Facebook Contact EMC Webmaster logo image for USA dot gov website. USA dot gov is the U.S

  2. Epithelial-myoepithelial carcinoma metastasis to the thoracic spine.

    PubMed

    Goodwin, C Rory; Khattab, Mohamed H; Sankey, Eric W; Crane, Genevieve M; McCarthy, Edward F; Sciubba, Daniel M

    2016-02-01

    Epithelial-myoepithelial carcinoma (EMC) is a very rare salivary gland malignancy accounting for less than 1% of salivary gland tumors, and classically arises from the parotid gland in females. Spinal cord compression caused by EMC metastasized from the parotid gland has only been described once in the literature to our knowledge. We report the first case of a patient with parotid EMC spinal metastasis undergoing a gross total resection with instrumented fusion. This case illustrates that an en bloc resection with a planned transgression through the spinal canal may be a reasonable option for EMC metastasized to the spine. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. ESA hardware for plant research on the International Space Station

    NASA Astrophysics Data System (ADS)

    Brinckmann, E.

    The long awaited launch of the European Modular Cultivation System (EMCS) will provide a platform on which long-term and shorter experiments with plants will be performed on the International Space Station (ISS). EMCS is equipped with two centrifuge rotors (600 mm diameter), which can be used for in-flight 1 g controls and for studies with acceleration levels from 0.001 g to 2.0 g. Several experiments are in preparation investigating gravity relating to gene expression, gravisensing and phototropism of Arabidopsis thaliana and lentil roots. The experiment-specific hardware provides growth chambers for seedlings and whole A. thaliana plants and is connected to the EMCS Life Support System. Besides in-flight video observation, the experiments will be evaluated post-flight by means of fixed or frozen material. EMCS will have for the first time the possibility to fix samples on the rotating centrifuge, allowing a detailed analysis of the process of gravisensing. About two years after the EMCS launch, ESA's Biolab will be launched in the European "Columbus" Module. In a similar way as in EMCS, Biolab will accommodate experiments with plant seedlings and automatic fixation processes on the centrifuge. The hardware concepts for these experiments are presented in this communication.

  4. New Developments in Spaceflight Hardware for Plant Research

    NASA Astrophysics Data System (ADS)

    Brinckmann, E.

    The long awaited launch of the European Modular Cultivation System (EMCS) will provide a platform to perform long term and shorter experiments with plants on the International Space Station (ISS). EMCS is equipped with two centrifuge rotors (600 mm diameter), which can be used for flight 1xg controls and for studies with accelerations from 0.001xg to 2.0xg. Several experiments are in preparation, investigating gravity related gene expressions, gravisensing and phototropism of Arabidopsis thaliana, fern spores and lentil rots. The experiment specific hardware provides growth chambers for seedlings and whole A. thaliana plants, connected to the EMCS Life Support System. Besides video observation, the experiments will be evaluated on ground by means of fixed or frozen material. EMCS will have for the first time the possibility to fix samples on the rotating centrifuge, allowing a detailed analysis of the process of gravisensing. Two years after EMCS, ESA's BIOLAB will be launched in the European "Columbus" Module. In a similar way as in EMCS, BIOLAB accommodates experiments with plant seedlings and automatic fixation processes on the centrifuge. The hardware concepts for these experiments will be presented in this communication.

  5. Dynamically Movable Exhausting Emc Sealing System

    DOEpatents

    Barringer, Dennis R.; Seminaro, Edward J.; Toffler, Harold M.

    2003-12-09

    A docking apparatus for printed circuit boards including a cassette housing, having a housing base, a housing cover and a housing wall, wherein the housing base and the housing wall are disposed relative to each other so as to define a housing cavity for containing a printed circuit card and wherein the housing wall includes a cable opening disposed so as to be communicated with the housing cavity, a housing bezel, disposed relative to the cassette housing so as to be associated with the cable opening, the housing bezel includes an outer bezel having a first plurality of openings and an inner bezel having a second plurality of apertures, the inner bezel in electrical communication with the printed circuit card, wherein said housing bezel is removable, and an EMC gasket disposed between the outer and inner bezels of said housing bezel, the EMC gasket configured to provide a removable EMC seal proximate the cable opening while still allowing airflow through the first and second plurality of apertures having the EMC gasket therebetween. A docking apparatus for printed circuit boards including a cassette housing, having a housing base, a housing cover and a housing wall, wherein the housing base and the housing wall are disposed relative to each other so as to define a housing cavity for containing a printed circuit card and wherein the housing wall includes a cable opening disposed so as to be communicated with the housing cavity, a housing bezel, disposed relative to the cassette housing so as to be associated with the cable opening, the housing bezel includes an outer bezel having a first plurality of openings and an inner bezel having a second plurality of apertures, the inner bezel in electrical communication with the printed circuit card, wherein said housing bezel is removable, and an EMC gasket disposed between the outer and inner bezels of said housing bezel, the EMC gasket configured to provide a removable EMC seal proximate the cable opening while still allowing airflow through the first and second plurality of apertures having the EMC gasket therebetween.

  6. Compatibility of the Radio Frequency Mass Gauge with Graphite-Epoxy Composite Tanks

    NASA Technical Reports Server (NTRS)

    Zimmerli, G. A.; Mueller, C. H.

    2015-01-01

    The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552/IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 - 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98%. Together, these results suggested that a tank constructed from graphite/epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 less than Q less than 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

  7. Compatibility of the Radio Frequency Mass Gauge with Composite Tanks

    NASA Technical Reports Server (NTRS)

    Zimmerli, Greg; Mueller, Carl

    2015-01-01

    The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98. Together, these results suggested that a tank constructed from graphite-epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 Q 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

  8. Lithium-Ion Electrolytes with Improved Safety Tolerance to High Voltage Systems

    NASA Technical Reports Server (NTRS)

    Smart, Marshall C. (Inventor); Prakash, Surya G. (Inventor); Bugga, Ratnakumar V. (Inventor); Krause, Frederick C. (Inventor)

    2015-01-01

    The invention discloses various embodiments of electrolytes for use in lithium-ion batteries, the electrolytes having improved safety and the ability to operate with high capacity anodes and high voltage cathodes. In one embodiment there is provided an electrolyte for use in a lithium-ion battery comprising an anode and a high voltage cathode. The electrolyte has a mixture of a cyclic carbonate of ethylene carbonate (EC) or mono-fluoroethylene carbonate (FEC) co-solvent, ethyl methyl carbonate (EMC), a flame retardant additive, a lithium salt, and an electrolyte additive that improves compatibility and performance of the lithium-ion battery with a high voltage cathode. The lithium-ion battery is charged to a voltage in a range of from about 2.0 V (Volts) to about 5.0 V (Volts).

  9. Antenna Measurements: Test & Analysis of the Radiated Emissions/Immunity of the NASA/Orion Spacecraft Dart Parachute Simulator & Prototype Capsule - The Crew Exploration Vehicle

    NASA Technical Reports Server (NTRS)

    Norgard, John D.

    2012-01-01

    For future NASA Manned Space Exploration of the Moon and Mars, a blunt body capsule, called the Orion Crew Exploration Vehicle (CEV), composed of a Crew Module (CM) and a Service Module (SM), with a parachute decent assembly is planned for reentry back to Earth. A Capsule Parachute Assembly System (CPAS) is being developed for preliminary prototype parachute drop tests at the Yuma Proving Ground (YPG) to simulate high-speed reentry to Earth from beyond Low-Earth-Orbit (LEO) and to provide measurements of position, velocity, acceleration, attitude, temperature, pressure, humidity, and parachute loads. The primary and secondary (backup) avionics systems on CPAS also provide mission critical firing events to deploy, reef, and release the parachutes in three stages (extraction, drogues, mains) using mortars and pressure cartridge assemblies. In addition, a Mid-Air Delivery System (MDS) is used to separate the capsule from the sled that is used to eject the capsule from the back of the drop plane. Also, high-speed and high-definition cameras in a Video Camera System (VCS) are used to film the drop plane extraction and parachute landing events. Intentional and unintentional radiation emitted from and received by antennas and electronic devices on/in the CEV capsule, the MDS sled, and the VCS system are being tested for radiated emissions/immunity (susceptibility) (RE/RS). To verify Electromagnetic Compatibility (EMC) of the Orion capsule, Electromagnetic Interference (EMI) measurements are being made inside a semi-anechoic chamber at NASA/JSC on the components of the CPAS system. Measurements are made at 1m from the components-under-test (CUT). In addition, EMI measurements of the integrated CEV system are being made inside a hanger at YPG. These measurements are made in a complete circle, at 30? angles or less, around the Orion Capsule, the spacecraft system under-test (SUT). Near-field B-Dot probe measurements on the surface of the Orion capsule are being extrapolated outward to the 1m standard distance for comparison to the MIL-STD radiated emissions limit, and far-field hybrid antenna measurements at 3m are being extrapolated inward to the 1m distance for similar comparisons.

  10. Radiated radiofrequency immunity testing of automated external defibrillators - modifications of applicable standards are needed

    PubMed Central

    2011-01-01

    Background We studied the worst-case radiated radiofrequency (RF) susceptibility of automated external defibrillators (AEDs) based on the electromagnetic compatibility (EMC) requirements of a current standard for cardiac defibrillators, IEC 60601-2-4. Square wave modulation was used to mimic cardiac physiological frequencies of 1 - 3 Hz. Deviations from the IEC standard were a lower frequency limit of 30 MHz to explore frequencies where the patient-connected leads could resonate. Also testing up to 20 V/m was performed. We tested AEDs with ventricular fibrillation (V-Fib) and normal sinus rhythm signals on the patient leads to enable testing for false negatives (inappropriate "no shock advised" by the AED). Methods We performed radiated exposures in a 10 meter anechoic chamber using two broadband antennas to generate E fields in the 30 - 2500 MHz frequency range at 1% frequency steps. An AED patient simulator was housed in a shielded box and delivered normal and fibrillation waveforms to the AED's patient leads. We developed a technique to screen ECG waveforms stored in each AED for electromagnetic interference at all frequencies without waiting for the long cycle times between analyses (normally 20 to over 200 s). Results Five of the seven AEDs tested were susceptible to RF interference, primarily at frequencies below 80 MHz. Some induced errors could cause AEDs to malfunction and effectively inhibit operator prompts to deliver a shock to a patient experiencing lethal fibrillation. Failures occurred in some AEDs exposed to E fields between 3 V/m and 20 V/m, in the 38 - 50 MHz range. These occurred when the patient simulator was delivering a V-Fib waveform to the AED. Also, we found it is not possible to test modern battery-only-operated AEDs for EMI using a patient simulator if the IEC 60601-2-4 defibrillator standard's simulated patient load is used. Conclusions AEDs experienced potentially life-threatening false-negative failures from radiated RF, primarily below the lower frequency limit of present AED standards. Field strengths causing failures were at levels as low as 3 V/m at frequencies below 80 MHz where resonance of the patient leads and the AED input circuitry occurred. This plus problems with the standard's' prescribed patient load make changes to the standard necessary. PMID:21801368

  11. Radiated radiofrequency immunity testing of automated external defibrillators--modifications of applicable standards are needed.

    PubMed

    Umberger, Ken; Bassen, Howard I

    2011-07-29

    We studied the worst-case radiated radiofrequency (RF) susceptibility of automated external defibrillators (AEDs) based on the electromagnetic compatibility (EMC) requirements of a current standard for cardiac defibrillators, IEC 60601-2-4. Square wave modulation was used to mimic cardiac physiological frequencies of 1-3 Hz. Deviations from the IEC standard were a lower frequency limit of 30 MHz to explore frequencies where the patient-connected leads could resonate. Also testing up to 20 V/m was performed. We tested AEDs with ventricular fibrillation (V-Fib) and normal sinus rhythm signals on the patient leads to enable testing for false negatives (inappropriate "no shock advised" by the AED). We performed radiated exposures in a 10 meter anechoic chamber using two broadband antennas to generate E fields in the 30-2500 MHz frequency range at 1% frequency steps. An AED patient simulator was housed in a shielded box and delivered normal and fibrillation waveforms to the AED's patient leads. We developed a technique to screen ECG waveforms stored in each AED for electromagnetic interference at all frequencies without waiting for the long cycle times between analyses (normally 20 to over 200 s). Five of the seven AEDs tested were susceptible to RF interference, primarily at frequencies below 80 MHz. Some induced errors could cause AEDs to malfunction and effectively inhibit operator prompts to deliver a shock to a patient experiencing lethal fibrillation. Failures occurred in some AEDs exposed to E fields between 3 V/m and 20 V/m, in the 38 - 50 MHz range. These occurred when the patient simulator was delivering a V-Fib waveform to the AED. Also, we found it is not possible to test modern battery-only-operated AEDs for EMI using a patient simulator if the IEC 60601-2-4 defibrillator standard's simulated patient load is used. AEDs experienced potentially life-threatening false-negative failures from radiated RF, primarily below the lower frequency limit of present AED standards. Field strengths causing failures were at levels as low as 3 V/m at frequencies below 80 MHz where resonance of the patient leads and the AED input circuitry occurred. This plus problems with the standard's' prescribed patient load make changes to the standard necessary.

  12. Enhanced methane production via repeated batch bioaugmentation pattern of enriched microbial consortia.

    PubMed

    Yang, Zhiman; Guo, Rongbo; Xu, Xiaohui; Wang, Lin; Dai, Meng

    2016-09-01

    Using batch and repeated batch cultivations, this study investigated the effects of bioaugmentation with enriched microbial consortia (named as EMC) on methane production from effluents of hydrogen-producing stage of potato slurry, as well as on the indigenous bacterial community. The results demonstrated that the improved methane production and shift of the indigenous bacterial community structure were dependent on the EMC/sludge ratio and bioaugmentation patterns. The methane yield and production rate in repeated batch bioaugmentation pattern of EMC were, respectively, average 15% and 10% higher than in one-time bioaugmentation pattern of EMC. DNA-sequencing approach showed that the enhanced methane production in the repeated batch bioaugmentation pattern of EMC mainly resulted from the enriched iron-reducing bacteria and the persistence of the introduced Syntrophomonas, which led to a rapid degradation of individual VFAs to methane. The findings contributed to understanding the correlation between the bioaugmentation of microbial consortia, community shift, and methane production. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. 55. E.M.C., photographer July 3, 1936 HUMBOLDT COUNTY, SECTION J, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    55. E.M.C., photographer July 3, 1936 HUMBOLDT COUNTY, SECTION J, HIGHWAY 1. 1-HUM-I-J #80, BITUMULS PORTION OF EXPERIMENTAL SECTION, E.M.C, 7-3-36. BACK READS: C/PROCESSING STABILIZING BITUMULS WITH BLADE AFTER BEING PROCESSED WITH SPRING TOOTH HARROW. Stamped office copy. - Redwood National & State Parks Roads, California coast from Crescent City to Trinidad, Crescent City, Del Norte County, CA

  14. Determination of first flush criteria using dynamic EMCs (event mean concentrations) on highway stormwater runoff.

    PubMed

    Kim, L H; Jeong, S M; Ko, S O

    2007-01-01

    Recently the Ministry of Environment in Korea has developed the total maximum daily load program in accordance with the target pollutant and its concentration goal on four major large rivers. Since the program is largely related to regional development, nonpoint source control is both important and topical. Of the various nonpoint sources, highways are stormwater intensive land uses since they are impervious and have high pollutant mass emissions from vehicular activity. The event mean concentration (EMC) is useful in estimating the loadings to receiving water bodies. However, the EMC does not provide information on the time varying changes in pollutant concentration or mass emissions, which are often important for best management practice development, or understanding shock loads. Therefore, in this study a new concept, the dynamic EMC determination method, will be introduced to clearly verify the relationship between EMC and the first flush effect. Three monitoring sites in Daejeon metropolitan city areas were equipped with an automatic rainfall gauge and a flow meter for accumulating the data such as rainfall and runoff flow. The dynamic EMC method was applied to more than 17 events, and the improved first flush criteria were determined on the ranges of storm duration and accumulated rainfall.

  15. Are prediction models for Lynch syndrome valid for probands with endometrial cancer?

    PubMed

    Backes, Floor J; Hampel, Heather; Backes, Katherine A; Vaccarello, Luis; Lewandowski, George; Bell, Jeffrey A; Reid, Gary C; Copeland, Larry J; Fowler, Jeffrey M; Cohn, David E

    2009-01-01

    Currently, three prediction models are used to predict a patient's risk of having Lynch syndrome (LS). These models have been validated in probands with colorectal cancer (CRC), but not in probands presenting with endometrial cancer (EMC). Thus, the aim was to determine the performance of these prediction models in women with LS presenting with EMC. Probands with EMC and LS were identified. Personal and family history was entered into three prediction models, PREMM(1,2), MMRpro, and MMRpredict. Probabilities of mutations in the mismatch repair genes were recorded. Accurate prediction was defined as a model predicting at least a 5% chance of a proband carrying a mutation. From 562 patients prospectively enrolled in a clinical trial of patients with EMC, 13 (2.2%) were shown to have LS. Nine patients had a mutation in MSH6, three in MSH2, and one in MLH1. MMRpro predicted that 3 of 9 patients with an MSH6, 3 of 3 with an MSH2, and 1 of 1 patient with an MLH1 mutation could have LS. For MMRpredict, EMC coded as "proximal CRC" predicted 5 of 5, and as "distal CRC" three of five. PREMM(1,2) predicted that 4 of 4 with an MLH1 or MSH2 could have LS. Prediction of LS in probands presenting with EMC using current models for probands with CRC works reasonably well. Further studies are needed to develop models that include questions specific to patients with EMC with a greater age range, as well as placing increased emphasis on prediction of LS in probands with MSH6 mutations.

  16. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > NOAH > IMPLEMENTATION SCHEDULLE Home Operational Products Experimental Data Verification Model Configuration Implementation Schedule Collaborators Documentation FAQ Code

  17. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > GEFS > IMPLEMENTATION SCHEDULLE Home Operational Products Experimental Data Verification Model Configuration Implementation Schedule Collaborators Documentation FAQ Code

  18. EMC Test Report Electrodynamic Dust Shield

    NASA Technical Reports Server (NTRS)

    Carmody, Lynne M.; Boyette, Carl B.

    2014-01-01

    This report documents the Electromagnetic Interference E M I evaluation performed on the Electrodynamic Dust Shield (EDS) which is part of the MISSE-X System under the Electrostatics and Surface Physics Laboratory at Kennedy Space Center. Measurements are performed to document the emissions environment associated with the EDS units. The purpose of this report is to collect all information needed to reproduce the testing performed on the Electrodynamic Dust Shield units, document data gathered during testing, and present the results. This document presents information unique to the measurements performed on the Bioculture Express Rack payload; using test methods prepared to meet SSP 30238 requirements. It includes the information necessary to satisfy the needs of the customer per work order number 1037104. The information presented herein should only be used to meet the requirements for which it was prepared.

  19. Cause and Prevention of Explosions Involving DC Casting of Aluminum Sheet Ingot

    NASA Astrophysics Data System (ADS)

    Richter, Ray T.; Ekenes, J. Martin

    The casting of aluminum alloy sheet ingot and T-bar presents the potential for some of the most volatile situations that can occur in DC (direct chill) and EMC (Electromagnetic) casting processes. Aluminum Association explosion incident data from over 300 explosions spanning a twenty-year period were reviewed and analyzed looking for common factors and repetitive reasons for explosions. Analysis of explosions occurring during the three stages of sheet ingot casting, `start of cast', `steady state' and `end of cast', were examined and prioritized. Case studies illustrate the need for understanding both technical and non-technical factors contributing to explosions involving molten metal. This paper identifies the major causes of explosions involving DC casting of aluminum alloy sheet ingot and makes recommendations for how to prevent the recurrence of such events and minimize the risk of injury.

  20. 46 CFR 161.002-1 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Number 3260: Flame Radiation Detectors for Automatic Fire Alarm Signaling, September, 1994—161.002-4(b.... IEC 533, Electromagnetic Compatibility of Electrical and Electronic Installations in Ships, 1977—161...

  1. A study of the applicability/compatibility of inertial energy storage systems to future space missions

    NASA Technical Reports Server (NTRS)

    Weldon, W. F.

    1980-01-01

    The applicability/compatibility of inertial energy storage systems like the homopolar generator (HPG) and the compensated pulsed alternator (CPA) to future space missions is explored. Areas of CPA and HPG design requiring development for space applications are identified. The manner in which acceptance parameters of the CPA and HPG scale with operating parameters of the machines are explored and the types of electrical loads which are compatible with the CPA and HPG are examined. Potential applications including the magnetoplasmadynamic (MPD) thruster, pulsed data transmission, laser ranging, welding and electromagnetic space launch are discussed.

  2. Genomic Characterization of a Newly Discovered Coronavirus Associated with Acute Respiratory Distress Syndrome in Humans

    PubMed Central

    van Boheemen, Sander; de Graaf, Miranda; Lauber, Chris; Bestebroer, Theo M.; Raj, V. Stalin; Zaki, Ali Moh; Osterhaus, Albert D. M. E.; Haagmans, Bart L.; Gorbalenya, Alexander E.; Snijder, Eric J.; Fouchier, Ron A. M.

    2012-01-01

    ABSTRACT A novel human coronavirus (HCoV-EMC/2012) was isolated from a man with acute pneumonia and renal failure in June 2012. This report describes the complete genome sequence, genome organization, and expression strategy of HCoV-EMC/2012 and its relation with known coronaviruses. The genome contains 30,119 nucleotides and contains at least 10 predicted open reading frames, 9 of which are predicted to be expressed from a nested set of seven subgenomic mRNAs. Phylogenetic analysis of the replicase gene of coronaviruses with completely sequenced genomes showed that HCoV-EMC/2012 is most closely related to Tylonycteris bat coronavirus HKU4 (BtCoV-HKU4) and Pipistrellus bat coronavirus HKU5 (BtCoV-HKU5), which prototype two species in lineage C of the genus Betacoronavirus. In accordance with the guidelines of the International Committee on Taxonomy of Viruses, and in view of the 75% and 77% amino acid sequence identity in 7 conserved replicase domains with BtCoV-HKU4 and BtCoV-HKU5, respectively, we propose that HCoV-EMC/2012 prototypes a novel species in the genus Betacoronavirus. HCoV-EMC/2012 may be most closely related to a coronavirus detected in Pipistrellus pipistrellus in The Netherlands, but because only a short sequence from the most conserved part of the RNA-dependent RNA polymerase-encoding region of the genome was reported for this bat virus, its genetic distance from HCoV-EMC remains uncertain. HCoV-EMC/2012 is the sixth coronavirus known to infect humans and the first human virus within betacoronavirus lineage C. PMID:23170002

  3. Status of Emergency Contraceptives in Europe One Year after the European Medicines Agency's Recommendation to Switch Ulipristal Acetate to Non-Prescription Status.

    PubMed

    Italia, Salvatore; Brand, Helmut

    2016-01-01

    In November 2014, the European Medicines Agency (EMA) recommended switching the emergency contraceptive (EMC) ulipristal acetate to non-prescription status. This study's objective is to assess the current legal status of the two EMCs ulipristal acetate and levonorgestrel in Europe and to report on the development of sales figures for EMCs since they were made freely available. Health authorities were contacted in autumn 2015 and asked about the current status of EMCs and whether the sales figures had changed after a switch to non-prescription status. Additionally, data on consumption were collected in 18 German community pharmacies. As of November 2015, most countries in the European Union (EU) have followed the EMA recommendation. Hungary kept the prescription-only status. In Malta, EMC drugs are not authorized. Germany and Croatia switched levonorgestrel to non-prescription status as well. Of the EU candidate and European Free Trade Association countries, ulipristal acetate is available without prescription in Norway and Bosnia and Herzegovina only. Several countries reported an increase in EMC sales since the switch. An EMA recommendation can strongly contribute to the harmonization of a drug's legal status in the EU. In most European countries, ulipristal acetate and/or levonorgestrel are now freely available. © 2016 The Author(s) Published by S. Karger AG, Basel.

  4. Comparison of maternal and fetal complications in elective and emergency cesarean section: a systematic review and meta-analysis.

    PubMed

    Yang, Xiao-Jing; Sun, Shan-Shan

    2017-09-01

    Though the same types of complication were found in both elective cesarean section (ElCS) and emergence cesarean section (EmCS), the aim of this study is to compare the rates of maternal and fetal morbidity and mortality between ElCS and EmCS. Full-text articles involved in the maternal and fetal complications and outcomes of ElCS and EmCS were searched in multiple database. Review Manager 5.0 was adopted for meta-analysis, sensitivity analysis, and bias analysis. Funnel plots and Egger's tests were also applied with STATA 10.0 software to assess possible publication bias. Totally nine articles were included in this study. Among these articles, seven, three, and four studies were involved in the maternal complication, fetal complication, and fetal outcomes, respectively. The combined analyses showed that both rates of maternal complication and fetal complication in EmCS were higher than those in ElCS. The rates of infection, fever, UTI (urinary tract infection), wound dehiscence, DIC (disseminated intravascular coagulation), and reoperation of postpartum women with EmCS were much higher than those with ElCS. Larger infant mortality rate of EmCS was also observed. Emergency cesarean sections showed significantly more maternal and fetal complications and mortality than elective cesarean sections in this study. Certain plans should be worked out by obstetric practitioners to avoid the post-operative complications.

  5. Ester-Based Electrolytes for Low-Temperature Li-Ion Cells

    NASA Technical Reports Server (NTRS)

    Smart, Marshall; Bugga, Ratnakumar

    2005-01-01

    Electrolytes comprising LiPF6 dissolved at a concentration of 1.0 M in five different solvent mixtures of alkyl carbonates have been found to afford improved performance in rechargeable lithium-ion electrochemical cells at temperatures as low as -70 C. These and other electrolytes have been investigated in continuing research directed toward extending the lower limit of practical operating temperatures of Li-ion cells. This research at earlier stages, and the underlying physical and chemical principles, were reported in numerous previous NASA Tech Briefs articles, the most recent being Low-EC-Content Electrolytes for Low-Temperature Li-Ion Cells (NPO-30226), NASA Tech Briefs, Vol. 27, No. 1 (January 2003), page 46. The ingredients of the present solvent mixtures are ethylene carbonate (EC), ethyl methyl carbonate (EMC), methyl butyrate (MB), methyl propionate (MP), ethyl propionate (EP), ethyl butyrate (EB), and ethyl valerate (EV). In terms of volume proportions of these ingredients, the present solvent mixtures are 1EC + 1EMC + 8MB, 1EC + 1EMC + 8EB, 1EC + 1EMC + 8MP, 1EC + 1EMC + 8EV, and 1EC + 9EMC. These electrolytes were placed in Liion cells containing carbon anodes and LiNi0.8Co0.2O2 cathodes, and the low-temperature electrical performances of the cells were measured. The cells containing the MB and MP mixtures performed best.

  6. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > NOAH > PEOPLE Home Operational Products Experimental Data Verification / Development Contacts Change Log Events Calendar Events People Numerical Forecast Systems Coming Soon. NOAA

  7. Sorption Isotherm of Southern Yellow Pine-High Density Polyethylene Composites.

    PubMed

    Liu, Feihong; Han, Guangping; Cheng, Wanli; Wu, Qinglin

    2015-01-20

    Temperature and relative humidity (RH) are two major external factors, which affect equilibrium moisture content (EMC) of wood-plastic composites (WPCs). In this study, the effect of different durability treatments on sorption and desorption isotherms of southern yellow pine (SYP)-high density polyethylene (HDPE) composites was investigated. All samples were equilibriumed at 20 °C and various RHs including 16%, 33%, 45%, 66%, 75%, 85%, 93%, and100%. EMCs obtained from desorption and absorption for different WPC samples were compared with Nelson's sorption isotherm model predictions using the same temperature and humidity conditions. The results indicated that the amount of moisture absorbed increased with the increases in RH at 20 °C. All samples showed sorption hysteresis at a fixed RH. Small difference between EMC data of WPC samples containing different amount of ultraviolet (UV) stabilizers were observed. Similar results were observed among the samples containing different amount of zinc borate (ZB). The experimental data of EMCs at various RHs fit to the Nelson's sorption isotherm model well. The Nelson's model can be used to predicate EMCs of WPCs under different RH environmental conditions.

  8. Developing energy and momentum conceptual survey (EMCS) with four-tier diagnostic test items

    NASA Astrophysics Data System (ADS)

    Afif, Nur Faadhilah; Nugraha, Muhammad Gina; Samsudin, Achmad

    2017-05-01

    Students' conceptions of work and energy are important to support the learning process in the classroom. For that reason, a diagnostic test instrument is needed to diagnose students' conception of work and energy. As a result, the researcher decided to develop Energy and Momentum Conceptual Survey (EMCS) instrument test into four-tier test diagnostic items. The purpose of this research is organized as the first step of four-tier test-formatted EMCS development as one of diagnostic test instruments on work and Energy. The research method used the 4D model (Defining, Designing, Developing and Disseminating). The instrument developed has been tested to 39 students in one of Senior High Schools. The resulting research showed that four-tier test-formatted EMCS is able to diagnose students' conception level of work and energy concept. It can be concluded that the development of four-tier test-formatted EMCS is one of potential diagnostic test instruments that able to obtain the category of students who understand concepts, misconceptions and do not understand about Work and Energy concept at all.

  9. Sorption Isotherm of Southern Yellow Pine—High Density Polyethylene Composites

    PubMed Central

    Liu, Feihong; Han, Guangping; Cheng, Wanli; Wu, Qinglin

    2015-01-01

    Temperature and relative humidity (RH) are two major external factors, which affect equilibrium moisture content (EMC) of wood-plastic composites (WPCs). In this study, the effect of different durability treatments on sorption and desorption isotherms of southern yellow pine (SYP)-high density polyethylene (HDPE) composites was investigated. All samples were equilibriumed at 20 °C and various RHs including 16%, 33%, 45%, 66%, 75%, 85%, 93%, and100%. EMCs obtained from desorption and absorption for different WPC samples were compared with Nelson’s sorption isotherm model predictions using the same temperature and humidity conditions. The results indicated that the amount of moisture absorbed increased with the increases in RH at 20 °C. All samples showed sorption hysteresis at a fixed RH. Small difference between EMC data of WPC samples containing different amount of ultraviolet (UV) stabilizers were observed. Similar results were observed among the samples containing different amount of zinc borate (ZB). The experimental data of EMCs at various RHs fit to the Nelson’s sorption isotherm model well. The Nelson’s model can be used to predicate EMCs of WPCs under different RH environmental conditions. PMID:28787943

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pramanik, Souvik, E-mail: souvick.in@gmail.com; Ghosh, Subir, E-mail: subir_ghosh2@rediffmail.com; Pal, Probir, E-mail: probirkumarpal@rediffmail.com

    In the present paper, dynamics of generalized charged particles are studied in the presence of external electromagnetic interactions. This particular extension of the free relativistic particle model lives in Non-Commutative κ-Minkowski space–time, compatible with Doubly Special Relativity, that is motivated to describe Quantum Gravity effects. Furthermore we have also considered the electromagnetic field to be dynamical and have derived the modified forms of Lienard–Wiechert like potentials for these extended charged particle models. In all the above cases we exploit the new and extended form of κ-Minkowski algebra where electromagnetic effects are incorporated in the lowest order, in the Dirac frameworkmore » of Hamiltonian constraint analysis.« less

  11. Experimental and analytical evaluation of ion thruster/spacecraft interactions

    NASA Technical Reports Server (NTRS)

    Carruth, M. R., Jr. (Editor)

    1981-01-01

    Studies were conducted to both identify the environment produced by ion thrusters and to assess the interaction of this environment on a typical spacecraft and typical science instruments. Spacecraft charging and the charge exchange that accompanies it is discussed in detail. Electromagnetic interference was characterized for ion engines. The electromagnetic compatibility of ion thrusters with spacecraft instruments was determined. The effects of ion thruster plumes on spacecraft were studied with particular emphasis on external surface currents.

  12. A literature review of transmission effectiveness and electromagnetic compatibility in home telemedicine environments to evaluate safety and security.

    PubMed

    Carranza, Noemí; Ramos, Victoria; Lizana, Francisca G; García, Jorge; del Pozo, Alejando; Monteagudo, José Luis

    2010-09-01

    The objective of this study was to determine already reported cases of transmission/reception failure and interferences to evaluate the safety and security of the new mobile home telemedicine systems. The literature published in the last 10 years (1998-2009) has been reviewed, by searching in several databases. Searches on transmission effectiveness and electromagnetic compatibility were made manually through journals, conference proceedings, and also the healthcare technology assessment agencies' Web pages. Search strategies developed through electronic databases and manual search identified a total of 886 references, with 44 finally being included in the results. They have been divided by technology in the transmission/reception effectiveness studies, and according to the type of medical device in the case of electromagnetic interferences studies. The study reveals that there are numerous publications on telemedicine and home-monitoring systems using wireless networks. However, literature on effectiveness in terms of connectivity and transmission problems and electromagnetic interferences is limited. From the collected studies, it can be concluded that there are transmission failures, low-coverage areas, errors in the transmission of packets, and so on. Moreover, cases of serious interferences in medical instruments have also been reported. These facts highlight the lack of studies and specific recommendations to be followed in the implementation of biomonitoring systems in domestic environments using wireless networks.

  13. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > RAP, HRRR > Home Operational Products Experimental Data Verification Model Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post

  14. Lossy chaotic electromagnetic reverberation chambers: Universal statistical behavior of the vectorial field

    NASA Astrophysics Data System (ADS)

    Gros, J.-B.; Kuhl, U.; Legrand, O.; Mortessagne, F.

    2016-03-01

    The effective Hamiltonian formalism is extended to vectorial electromagnetic waves in order to describe statistical properties of the field in reverberation chambers. The latter are commonly used in electromagnetic compatibility tests. As a first step, the distribution of wave intensities in chaotic systems with varying opening in the weak coupling limit for scalar quantum waves is derived by means of random matrix theory. In this limit the only parameters are the modal overlap and the number of open channels. Using the extended effective Hamiltonian, we describe the intensity statistics of the vectorial electromagnetic eigenmodes of lossy reverberation chambers. Finally, the typical quantity of interest in such chambers, namely, the distribution of the electromagnetic response, is discussed. By determining the distribution of the phase rigidity, describing the coupling to the environment, using random matrix numerical data, we find good agreement between the theoretical prediction and numerical calculations of the response.

  15. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > NOAH > HOME Home Operational Products Experimental Data Verification Model PAGE LOGO NCEP HOME NWS LOGO NOAA HOME NOAA HOME Disclaimer for this non-operational web page

  16. [A rare tumor of the parapharyngeal space: myxoid chondrosarcoma].

    PubMed

    Bahri, I; Boudawara, T; Sellami, A; Khabir, A; Ghorgel, M; Drira, M; Daoud, J; Jlidi, R

    2002-01-01

    Extrasqueletal myxoid chondrosarcoma (EMC) is an uncommon soft tissue malignant tumor, locally aggressive with a high incidence of distant metastasis. It has distinctive clinical, immunophenotypic, cytogenetic and ultrastructural features. Most EMC are associated with the translocation t(9;22) (q22;q12). Their occurrence in the parapharyngeal space is extremely rare. Our objective is to discuss the difficulties of the histological diagnosis of EMC and to describe its immunophenotypic, cytogenetic features and clinical behavior. We report a case of a 67 years old woman who presented with a five months history of dysphagia. The oral examination found a mass displacing the posterior and left walls of the pharynx. Surgical resection of the tumor was undertaken. The pathologic examination concluded to the diagnosis of an EMC of the left parapharygeal space. Now, the patient is receiving an adjuvant radiotherapy.

  17. Increased levels of inflammatory cytokines in the female reproductive tract are associated with altered expression of proteases, mucosal barrier proteins, and an influx of HIV-susceptible target cells.

    PubMed

    Arnold, Kelly B; Burgener, Adam; Birse, Kenzie; Romas, Laura; Dunphy, Laura J; Shahabi, Kamnoosh; Abou, Max; Westmacott, Garrett R; McCorrister, Stuart; Kwatampora, Jessie; Nyanga, Billy; Kimani, Joshua; Masson, Lindi; Liebenberg, Lenine J; Abdool Karim, Salim S; Passmore, Jo-Ann S; Lauffenburger, Douglas A; Kaul, Rupert; McKinnon, Lyle R

    2016-01-01

    Elevated inflammatory cytokines (EMCs) at mucosal surfaces have been associated with HIV susceptibility, but the underlying mechanisms remain unclear. We characterized the soluble mucosal proteome associated with elevated cytokine expression in the female reproductive tract. A scoring system was devised based on the elevation (upper quartile) of at least three of seven inflammatory cytokines in cervicovaginal lavage. Using this score, HIV-uninfected Kenyan women were classified as either having EMC (n=28) or not (n=68). Of 455 proteins quantified in proteomic analyses, 53 were associated with EMC (5% false discovery rate threshold). EMCs were associated with proteases, cell motility, and actin cytoskeletal pathways, whereas protease inhibitor, epidermal cell differentiation, and cornified envelope pathways were decreased. Multivariate analysis identified an optimal signature of 16 proteins that distinguished the EMC group with 88% accuracy. Three proteins in this signature were neutrophil-associated proteases that correlated with many cytokines, especially GM-CSF (granulocyte-macrophage colony-stimulating factor), IL-1β (interleukin-1β), MIP-3α (macrophage inflammatory protein-3α), IL-17, and IL-8. Gene set enrichment analyses implicated activated immune cells; we verified experimentally that EMC women had an increased frequency of endocervical CD4(+) T cells. These data reveal strong linkages between mucosal cytokines, barrier function, proteases, and immune cell movement, and propose these as potential mechanisms that increase risk of HIV acquisition.

  18. Music and the brain - design of an MEG compatible piano.

    PubMed

    Chacon-Castano, Julian; Rathbone, Daniel R; Hoffman, Rachel; Heng Yang; Pantazis, Dimitrios; Yang, Jason; Hornberger, Erik; Hanumara, Nevan C

    2017-07-01

    Magnetoencephalography (MEG) neuroimaging has been used to study subjects' responses when listening to music, but research into the effects of playing music has been limited by the lack of MEG compatible instruments that can operate in a magnetically shielded environment without creating electromagnetic interference. This paper describes the design and preliminary testing of an MEG compatible piano keyboard with 25 full size keys that employs a novel 3-state optical encoder design and electronics to provide realistic velocity-controlled volume modulation. This instrument will allow researchers to study musical performance on a finer timescale than fMRI and enable a range of MEG studies.

  19. Diffusional Motion of Redox Centers in Carbonate Electrolytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Kee Sung; Rajput, Nav Nidhi; Wei, Xiaoliang

    2014-09-14

    Ferrocene (Fc) and N-(ferrocenylmethyl)-N,N-dimethyl-N-ethylammonium bistrifluoromethyl-sulfonimide (Fc1N112-TFSI) were dissolved in carbonate solvents and self diffusion coefficents (D) of solutes and solvents were measured by 1H and 19F pulsed field gradient (PFG) nuclear magnetic resonance (NMR) spectroscopy. The organic solvents were propylene carbonate (PC), ethyl methyl carbonate (EMC) and a ternary mixture that also includes ethylene carbonate (EC). Results from NMR studies over the temperature range of 0-50 °C and for various concentrations (0.25 - 1.7 M) of Fc1N112-TFSI are compared to values of D simulated with classical molecular dynamics (MD). The measured self-diffusion coefficients gradually decreased as the Fc1N112-TFSI concentration increasedmore » in all solvents. Since the peaks for the two ions (Fc1N212 and TFSI) are separated in one-dimensional NMR spectra, separate diffusion coefficients could be measured and DTFSI is larger than DFc1N112 in all samples measured. The EC, PC and EMC have the same D in the neat solvent mixture and when Fc is dissolved in EC/PC/EMC at a concentration of 0.2 M, probably due to the interactions between common carbonyl structures within EC, PC and EMC. A difference in D (DPC < DEC < DEMC), and both a higher Ea for translational motion and higher effective viscosity for PC in the mixture containing Fc1N112-TFSI reflect the interaction between PC and Fc1N112+, which is a relatively stronger interaction than that between Fc1N112+ and other solvent species. In the EC/PC/EMC solution that is saturated with Fc1N112-TFSI, we find that DPC = DEC = DEMC and Fc1N112+ and all components of the EC/PC/EMC solution have the same Ea for translational motion, while the ratio DEC/PC/EMC/DFc1N112+ is approximately 3. These results reflect the lack of available free volume for independent diffusion in the saturated solution. The Fc1N112+ transference numbers lie around 0.4 and increases slightly as the temperature is increased in the PC and EMC solvents. The trends observed for D from simulations are in good agreement with experimental results and provide molecular level understanding of the solvation structure of Fc1N112-TFSI dissolved in EC/PC/EMC.« less

  20. In-harbor and at-sea electromagnetic compatibility survey for maritime satellite L-band shipboard terminal

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Geostationary maritime satellites, one over the Pacific and one over the Atlantic Ocean, are planned to make available high-speed communications and navigation (position determination) services to ships at sea. A shipboard satellite terminal, operating within the authorized maritime L-band, 1636.5 to 1645.0 MHz, will allow ships to pass voice, teletype, facsimile, and data messages to shore communication facilities with a high degree of reliability. The shore-to-ship link will also operate in the maritime L-band from 1535.0 to 1543.5 MHz. A significant number or maritime/commercial ships are expected to be equipped with an L-band satellite terminal by the year 1980, and so consequently, there is an interest in determining electromagnetic compatibility between the proposed L-band shipboard terminal and existing, on-board, shipboard communications/electronics and electrical systems, as well as determining the influence of shore-based interference sources. The shipboard electromagnetic interference survey described was conducted on-board the United States Line's American Leader class (15,690 tons) commercial container ship, the "American Alliance" from June 16 to 20, 1974. Details of the test plan and measurements are given.

  1. Design, development, and clinical evaluation of the electronic mobility cane for vision rehabilitation.

    PubMed

    Bhatlawande, Shripad; Mahadevappa, Manjunatha; Mukherjee, Jayanta; Biswas, Mukul; Das, Debabrata; Gupta, Somedeb

    2014-11-01

    This paper proposes a new electronic mobility cane (EMC) for providing obstacle detection and way-finding assistance to the visually impaired people. The main feature of this cane is that it constructs the logical map of the surrounding environment to deduce the priority information. It provides a simplified representation of the surrounding environment without causing any information overload. It conveys this priority information to the subject by using intuitive vibration, audio or voice feedback. The other novel features of the EMC are staircase detection and nonformal distance scaling scheme. It also provides information about the floor status. It consists of a low power embedded system with ultrasonic sensors and safety indicators. The EMC was subjected to series of clinical evaluations in order to verify its design and to assess its ability to assist the subjects in their daily-life mobility. Clinical evaluations were performed with 16 totally blind and four low vision subjects. All subjects walked controlled and the real-world test environments with the EMC and the traditional white cane. The evaluation results and significant scores of subjective measurements have shown the usefulness of the EMC in vision rehabilitation services.

  2. Estimation of limit strains in disk-type flywheels made of a compliant elastomeric matrix composite undergoing radial creep

    NASA Astrophysics Data System (ADS)

    Portnov, G. G.; Bakis, Ch. E.

    2000-01-01

    Fiber reinforced elastomeric matrix composites (EMCs) offer several potential advantages for construction of rotors for flywheel energy storage systems. One potential advantage, for safety considerations, is the existence of maximum stresses near the outside radius of thick circumferentially wound EMC disks, which could lead to a desirable self-arresting failure mode at ultimate speeds. Certain unidirectionally reinforced EMCs, however, have been noted to creep readily under the influence of stress transverse to the fibers. In this paper, stress redistribution in a spinning thick disk made of a circumferentially filament wound EMC material on a small rigid hub has been analyzed with the assumption of total radial stress relaxation due to radial creep. It is shown that, following complete relaxation, the circumferential strains and stresses are maximized at the outside radius of the disk. Importantly, the radial tensile strains are three times greater than the circumferential strains at any given radius. Therefore, a unidirectional EMC material system that can safely endure transverse tensile creep strains of at least three times the elastic longitudinal strain capacity of the same material is likely to maintain the theoretically safe failure mode despite complete radial stress relaxation.

  3. EMCS Experiment Container for the Plant Gravity Perception Experiment

    NASA Image and Video Library

    2018-02-08

    iss054e037079 (Feb. 8, 2018) --- Plant Gravity Perception experiment in a centrifuge on a European Modular Cultivation System (EMCS) Experiment Container (EC) to test the gravity-sensing ability of plants in microgravity.

  4. UAVEMI Project: Numerical and Experimental EM Immunity Assessment of UAV for HIRF and Lightning Indirect Effects

    NASA Astrophysics Data System (ADS)

    Garcia, Salvador G.; Silvia, Ferran; Escot, David; Pascual, Enrique; Pantoja, Mario F.; Riu, Pere; Anon, Manuel; Alvarez, Jesus; Cabello, M.; Pous, Marc; Fernandez, Sergio; Trallero, Rafael; Poyatos, David; Nuno, Luis

    2016-05-01

    The UAVEMI project, funded by the Spanish Ministry of Economy and Competitiveness, gathers a consortium formed by several research and development institutions and one industrial partner. The main goal is to develop innovative experimental and numerical approaches for the assessment of the electromagnetic compatibility of unmanned air vehicles, under high intensity radiated fields, lightning indirect effects and non-nuclear electromagnetic pulses. This contribution describes the capabilities currently being developed under the project.

  5. Digital I and C system upgrade integration technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, H. W.; Shih, C.; Wang, J. R.

    2012-07-01

    This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digitalmore » Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A solid review can assure the quality of the digital I and C system replacement. (authors)« less

  6. Water quality of an urban wet detention pond in Madison, Wisconsin, 1987-88

    USGS Publications Warehouse

    House, L.B.; Waschbusch, R.J.; Hughes, P.E.

    1993-01-01

    A 5,670-sq m wet detention pond was monitored by the U.S. Geological Survey to determine its effect on the water quality of urban runoff. The pond has a drainage area of 0.96-sq km, composed primarily of single-family residential land use. Event-mean concentrations (EMC) were determined from samples collected for sediment, nutrients, and selected metals at the pond's inflow and outflow sites. EMC samples were collected for 64 runoff events during the study period from February 1987 to April 1988. Storm precipitation ranged from 1 to 51 mm during these events. Inflow and outflow EMC and constituent loads were compared to determine the trap efficiency of the pond. Trap efficiency varied considerably among water-quality constituents. In general, the detention pond decreased the EMC of sampled constituents at the outlet compared to the inlet. The median decrease in EMC for suspended solids was 88 percent, 60 percent for total chemical oxygen demand (COD), 43 percent for total phosphorus, 38 percent for total Kjeldahl nitrogen, 65 percent for total nitrite plus nitrate, and 71 percent for total lead. A notable exception to the general decrease in EMC is for chloride. The EMC for chloride was generally higher in outflow from the pond than in the inflow. This is attributed to an unmonitored influx of chloride to the pond during the winter that subsequently was flushed out during monitored runoff events. The total study-period loads of most constituents were less leaving the pond than the loads entering it. This decrease is attributed to the constituents transported on suspended sediment being deposited in the pond. The decrease in total load of suspended solids was 88 percent, 62 percent for total COD, 58 percent for total phosphorus, 46 percent for total Kjeldahl nitrogen, 62 percent for total nitrite plus nitrate, 97 percent for total copper, and 93 percent for total lead. (USGS)

  7. EMCS EC Connector Inspection Imagery

    NASA Image and Video Library

    2018-02-02

    iss054e026863 (Feb. 2, 2018) --- The Plant Gravity Perception experiment in a centrifuge before its second run on the European Modular Cultivation System (EMCS) Experiment Container (EC) to test the gravity-sensing ability of plants in microgravity.

  8. --No Title--

    Science.gov Websites

    2008073000 2008072900 2008072800 Background information bias reduction = ( | domain-averaged ensemble mean bias | - | domain-averaged bias-corrected ensemble mean bias | / | domain-averaged bias-corrected ensemble mean bias | NAEFS Products | NAEFS | EMC Ensemble Products EMC | NCEP | National Weather Service

  9. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > NAM > EXPERIMENTAL DATA Home NAM Operational Products HIRESW Operational Products Operational Forecast Graphics Experimental Forecast Graphics Verification and Diagnostics Model PARALLEL/EXPERIMENTAL MODEL FORECAST GRAPHICS OPERATIONAL VERIFICATION / DIAGNOSTICS PARALLEL VERIFICATION

  10. Primary extraskeletal myxoid chondrosarcoma in cerebellum: A case report with literature review.

    PubMed

    Qin, You; Zhang, Hai-Bo; Ke, Chang-Shu; Huang, Jing; Wu, Bian; Wan, Chao; Yang, Chen-Su; Yang, Kun-Yu

    2017-11-01

    Extraskeletal myxoid chondrosarcoma (EMC) is a rare malignant neoplasm of which intracranial EMC is the rarest. We present an unusual case report of a 41-year-old woman who was sent to the emergency department for a sudden headache and other symptoms related to increased intracranial pressure. Emergent CT revealed an occupying lesion in the left cerebellum with surrounding edema. A complete surgical excision of the lesion through a transcortical approach was performed. After the operation, this patient received adjuvant radiotherapy and temozolomide treatment. Pathology diagnosis was an intracranial EMC. The patient survives with no tumor recurrence as of the last follow-up. Progression-free survival exceeded 20 months. We have reviewed the literature and here summarize the diagnosis and treatment options for intracranial EMC. Diagnosis and treatment options of this rare disease are discussed. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  11. Plant growth using EMCS hardware on the ISS.

    PubMed

    Iversen, Tor-Henning; Fossum, Knut R; Svare, Hakon; Johnsson, Anders; Schiller, Peter

    2002-07-01

    Under separate contracts with ESA (FUMO and ERM Study) and as a link in the development of the European Modular Cultivation System's (EMCS) functionality and biocompatibility, plant studies have been performed at The Plant Biocentre in Trondheim, Norway. The main goal was to test whether the breadboards containing the major components planned for use in the EMCS would be optimal for space experiments with plant material. The test plans and the experimental set-up for the verification of biocompatibility and biological functionality included the use of a few model plant species including cress (Lepidium sativum L.) and Arabidopsis thaliana. The plants were tested at different developmental levels of morphological and physiological complexity (illumination, life support, humidity control, water supply, observation, short- and long-term plant growth experiments and contamination prevention). Results from the tests show that the EMCS concept is useful for long duration plant growth on the ISS.

  12. [Study on the characteristics of combined sewer overflow from the high density residential area in Shanghai].

    PubMed

    Li, He; Li, Tian

    2006-08-01

    The urban non-point pollution has become main pollution resource of urban water bodies of Shanghai. Character of combined sewer overflow from watershed SA in Shanghai was studied, and the correlation of influence factors to the EMCs of overflows was discussed. It is found that the EMCs of COD, BOD, SS, NH3-N, TN, TP are 614 mg/L, 208.5 mg/L, 684 mg/L, 17.6 mg/L, 29.8 mg/L, 3.0 mg/L respectively, and the values obtained herein are much higher than the documented data from other countries. From the probability plot of the EMCs, it is found that the BOD has the best fitness for lognormal distribution; and correlation between the EMCs of COD, SS and the ratio of antecedent dry weather time to rain duration is quite good.

  13. Pollutant concentrations and pollution loads in stormwater runoff from different land uses in Chongqing.

    PubMed

    Wang, Shumin; He, Qiang; Ai, Hainan; Wang, Zhentao; Zhang, Qianqian

    2013-03-01

    To investigate the distribution of pollutant concentrations and pollution loads in stormwater runoff in Chongqing, six typical land use types were selected and studied from August 2009 to September 2011. Statistical analysis on the distribution of pollutant concentrations in all water samples shows that pollutant concentrations fluctuate greatly in rainfall-runoff, and the concentrations of the same pollutant also vary greatly in different rainfall events. In addition, it indicates that the event mean concentrations (EMCs) of total suspended solids (TSS) and chemical oxygen demand (COD) from urban traffic roads (UTR) are significantly higher than those from residential roads (RR), commercial areas (CA), concrete roofs (CR), tile roofs (TRoof), and campus catchment areas (CCA); and the EMCs of total phosphorus (TP) and NH3-N from UTR and CA are 2.35-5 and 3 times of the class-II standard values specified in the Environmental Quality Standards for Surface Water (GB 3838-2002). The EMCs of Fe, Pb and Cd are also much higher than the class-III standard values. The analysis of pollution load producing coefficients (PLPC) reveals that the main pollution source of TSS, COD and TP is UTR. The analysis of correlations between rainfall factors and EMCs/PLPC indicates that rainfall duration is correlated with EMCs/PLPC of TSS for TRoof and TP for UTR, while rainfall intensity is correlated with EMCs/PLPC of TP for both CR and CCA. The results of this study provide a reference for better management of non-point source pollution in urban regions.

  14. EMC HWRF Weekly Meeting Homepage

    Science.gov Websites

    structure using idealized HWRF simulations with GFS and MYJ PBL schemes by Jun Zhang (HRD/AOML) NOAA- MoES Zhan Zhang(EMC) (NOTE: Links open presentations in a new window) Please e-mail comments, questions, or

  15. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > Mesoscale Modeling > PEOPLE Home Mission Models R & D Collaborators Documentation Change Log People Calendar References Verification/Diagnostics Tropical & Extratropical Cyclone Tracks & Verification Implementation Info FAQ Disclaimer More Info MESOSCALE MODELING PEOPLE

  16. Mars Surface Habitability Options

    NASA Technical Reports Server (NTRS)

    Howe, A. Scott; Simon, Matthew; Smitherman, David; Howard, Robert; Toups, Larry; Hoffman, Stephen J.

    2015-01-01

    This paper reports on current habitability concepts for an Evolvable Mars Campaign (EMC) prepared by the NASA Human Spaceflight Architecture Team (HAT). For many years NASA has investigated alternative human Mars missions, examining different mission objectives, trajectories, vehicles, and technologies; the combinations of which have been referred to as reference missions or architectures. At the highest levels, decisions regarding the timing and objectives for a human mission to Mars continue to evolve while at the lowest levels, applicable technologies continue to advance. This results in an on-going need for assessments of alternative system designs such as the habitat, a significant element in any human Mars mission scenario, to provide meaningful design sensitivity characterizations to assist decision-makers regarding timing, objectives, and technologies. As a subset of the Evolvable Mars Campaign activities, the habitability team builds upon results from past studies and recommends options for Mars surface habitability compatible with updated technologies.

  17. EMCS Experiment Container Replacement

    NASA Image and Video Library

    2018-01-26

    iss054e023800 (Jan. 26, 2018) --- NASA astronaut Joe Acaba placing an Experiment Container (EC) on the European Modular Cultivation System (EMCS) for the the first run of the Plant Gravity Perception experiment to test the gravity-sensing ability of plants in microgravity.

  18. EMCS Experiment Container Replacement

    NASA Image and Video Library

    2018-01-26

    iss054e023776 (Jan. 26, 2018) --- NASA astronaut Joe Acaba removing an Experiment Container (EC) on the European Modular Cultivation System (EMCS) for the the first run of the Plant Gravity Perception experiment to test the gravity-sensing ability of plants in microgravity.

  19. EMC: Mission Statement

    Science.gov Websites

    EMC: Mission Statement Mesoscale Modeling Branch Mission Statement The Mesoscale Modeling Branch , advanced numerical techniques applied to mesoscale modeling problems, parameterization of mesoscale new observing systems. The Mesoscale Modeling Branch publishes research results in various media for

  20. National Centers for Environmental Prediction

    Science.gov Websites

    Organization Search Enter text Search Navigation Bar End Cap Search EMC Go Branches Global Climate and Weather / VISION | About EMC Click on a model logo to go to its home page RTOFS Global RTOFS Global RTOFS Atlantic

  1. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > NAM > Home NAM Operational Products HIRESW Operational Products Operational Forecast Graphics Experimental Forecast Graphics Verification and Diagnostics Model Configuration Collaborators Documentation and Code FAQ Operational Change Log Parallel Experiment Change Log Contacts

  2. Energy Management Control Systems: Tools for Energy Savings and Environmental Protection

    NASA Technical Reports Server (NTRS)

    Zsebik, Albin; Zala, Laszlo F.

    2002-01-01

    The change in the price of energy has encouraged the increase of energy efficiency. This report will discuss a tool to promote energy efficiency in intelligent buildings, energy management control systems (EMCS). In addition to the online control of energy production, supply, and consumption, the function of the EMCS is to support short- and long-term planning of the system operation as well as to collect, store, and regularly evaluate operation data. The strategies behind planning and implementing the EMCS as well as the manipulating the resulting data are discussed in this report.

  3. EMI / EMC Design for Class D Payloads (Resource Prospector / NIRVSS)

    NASA Technical Reports Server (NTRS)

    Forgione, Josh; Benton, Joshua Eric; Thompson, Sarah; Colaprete, Anthony

    2015-01-01

    EMI/EMC techniques are applied to a Class D instrument (NIRVSS) to achieve low noise performance and reduce risk of EMI/EMC testing failures and/or issues during system integration and test. Basic techniques are not terribly expensive or complex, but do require close coordination between electrical and mechanical staff early in the design process. Low-cost methods to test subsystems on the bench without renting an EMI chamber are discussed. This method was applied to the NIRVSS instrument and achieved improvements up to 59dB on conducted emissions measurements between hardware revisions.

  4. Use of Additives to Improve Performance of Methyl Butyrate-Based Lithium-Ion Electrolytes

    NASA Technical Reports Server (NTRS)

    Smart, Marshall C.; Bugga, Ratnakumar V.

    2011-01-01

    This work addresses the need for robust rechargeable batteries that can operate well over a wide temperature range. To this end, a number of electrolyte formulations have been developed that incorporate the use of electrolyte additives to improve the high-temperature resilience, low-temperature power capability, and life characteristics of methyl butyrate-based electrolyte solutions. These electrolyte additives include mono-fluoroethylene carbonate (FEC), lithium oxalate, vinylene carbonate (VC), and lithium bis(oxalato)borate (LiBOB), which have been shown to result in improved high-temperature resilience of all carbonate-based electrolytes. Improved performance has been demonstrated of Li-ion cells with methyl butyrate-based electrolytes, including 1.20M LiPF6 in EC+EMC+MB (20:20:60 v/v %); 1.20M LiPF6 in EC+EMC+MB (20:20:60 v/v %) + 2% FEC; 1.20M LiPF6 in EC+EMC+MB (20:20:60 v/v %) + 4% FEC; 1.20M LiPF6 in EC+EMC+MB (20:20:60 v/v %) + lithium oxalate; 1.20M LiPF6 in EC+EMC+MB (20:20:60 v/v %) + 2% VC; and 1.20M LiPF6 in EC+EMC+MB (20:20:60 v/v %) + 0.10M LiBOB. These electrolytes have been shown to improve performance in MCMB-LiNiCoO2 and graphite-LiNi1/3Co1/3Mn1/3O2 experimental Li-ion cells. A number of LiPF6-based mixed carbonate electrolyte formulations have been developed that contain ester co-solvents, which have been optimized for operation at low temperature, while still providing reasonable performance at high temperature. For example, a number of ester co-solvents were investigated, including methyl propionate (MP), ethyl propionate (EP), methyl butyrate (MB), ethyl butyrate (EB), propyl butyrate (PB), and butyl butyrate (BB) in multi-component electrolytes of the following composition: 1.0M LiPF6 in ethylene carbonate (EC) + ethyl methyl carbonate (EMC) + X (20:60:20 v/v %) [where X = ester co-solvent]. ["Optimized Car bon ate and Ester-Based Li-Ion Electrolytes", NASA Tech Briefs, Vol. 32, No. 4 (April 2008), p. 56.] Focusing upon improved rate capability at low temperatures (i.e., 20 to 40 C), this approach was optimized further, resulting in the development of 1.20M LiPF6 in EC+EMC+MP (20:20:60 v/v %) and 1.20M LiPF6 in EC+EMC+EB (20:20:60 v/v %), which were demonstrated to operate well over a wide temperature range in MCMB-LiNiCoAlO2 and Li4Ti5O12(-)LiNiCoAlO2 prototype cells.

  5. EMC: Verification

    Science.gov Websites

    , GFS, RAP, HRRR, HIRESW, SREF mean, International Global Models, HPC analysis Precipitation Skill Scores : 1995-Present NAM, GFS, NAM CONUS nest, International Models EMC Forecast Verfication Stats: NAM ) Real Time Verification of NCEP Operational Models against observations Real Time Verification of NCEP

  6. SiRen: Leveraging Similar Regions for Efficient and Accurate Variant Calling

    DTIC Science & Technology

    2015-05-30

    Cloudera, EMC2, Ericsson, Facebook, Guavus, HP, Huawei, Informatica , Intel, Microsoft, NetApp, Pivotal, Samsung, Schlumberger, Splunk, Virdata and VMware...EMC2, Ericsson, Facebook, Guavus, HP, Huawei, Informatica , Intel, Microsoft, NetApp, Pivotal, Samsung, Schlumberger, Splunk, Virdata and VMware

  7. Endometrial cells on Pap tests: ideal reporting is more complex than just finding the right age.

    PubMed

    Fischer, Gabor; Haddad, Maha; Cormier, Karen

    2017-07-01

    The age for reporting normal endometrial cells (EMCs) on Pap tests was changed to ≥ 45 years in the latest Bethesda update (2014). This recommendation is solely based on age with no consensus on optimal reporting guidelines. Pap tests with EMCs for women ≥40 years were retrieved from our Laboratory Information System (LIS). Patient age, last menstrual period (LMP) and available follow-up histology were recorded. Follow-up diagnoses were categorized as: no significant pathology, benign, hyperplasia ± atypia, or malignant. The Fisher's exact test was used to assess the association between categorical variables, p < .05 (two-sided test) was considered significant. Of the 352 cases with EMCs, 155 had surgical follow-up. They showed no malignancy in the 89 women between 40-49 years, compared with five malignancies in the 66 women 50+ years (p = .016). The number of cases with significant pathology (hyperplasia and malignant) was 4 (40-49 years) vs. 11 (50+ years) (p = 0.029). The LMP was inconsistently provided (57%) and women identified as postmenopausal on requisition comprised all the malignancies and half the hyperplasias. Combined effort by pathologists and clinicians necessitates determining the best standardized clinicopathologic guidelines to report EMCs and appropriate follow-up. Increasing the required age to ≥50 years would provide more optimal patient management; however, there are other considerations beyond age. Reporting EMCs in postmenopausal women is a reasonable alternative requiring consistent and accurate recording of LMP. Improving provided information for pathologists, determining reporting requirements for EMCs and standardizing clinical follow-up should be a multidisciplinary effort. Diagn. Cytopathol. 2017;45:587-591. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. The examination of the spread of the leachates coming out of a solid waste disposal area on the ground with geophysical and geochemical methods (Sivas, Turkey)

    NASA Astrophysics Data System (ADS)

    Özel, Sevda; Yılmaz, Ali; Emin Candansayar, M.

    2017-03-01

    This study has been conducted in the irregular solid waste disposal area in the city of Sivas. The pollution spread formed by the leachates coming out of the disposal area has been examined with geophysical and geochemical works in this study. For this reason, the spread of the leachate pollution expanding in different geological units at both sides of a creek on the ground has been examined. For this purpose, the pollution spread has been examined with the methods of Direct Current Resistivity (DCR) and Electromagnetic Conductivity (EMC) and soil analyses. In the DCR method, 2D inversion of each sounding-profile datum measured alongside the lines parallel to each other and 3D inversion of the data measured in all the lines have been used in the interpretations. Apparent conductivity map has been attained from EMC measurements. The results of heavy metal analyses in the soil samples taken alongside the Haçin Creek have been assessed with the Spider diagram method. It has been determined that the flow of the leachate from geophysical models is in a SE direction and towards Kızılırmak and it continues vertically deeper than 4 m. In addition, it has been understood that the flow direction of the leachate is inspected by the geological structures. It has been understood from the geochemical results that the pollution in the soil stems from the leachate. In this way, it has been observed that the underground and surface water resources in the territory are under the threat of the pollution occurring due to the leachate.

  9. The development of optimal on-premise Electronic Message Center (EMC) lighting levels and sign lighting measurement techniques.

    DOT National Transportation Integrated Search

    2013-02-01

    Research conducted recently for the United States Sign Council Foundation found no consensus in the research : literature or the practices of the commercial electronic message center (EMC) industry on lighting measurement : or appropriate lighting le...

  10. National Centers for Environmental Prediction

    Science.gov Websites

    Statistics Observational Data Processing Data Assimilation Monsoon Desk Model Transition Seminars Seminar ) of the Environmental Modeling Center (EMC) conducts a program of research and development in support Climate Prediction (NCWCP) 5830 University Research Court College Park, MD 20740 Page Author: EMC

  11. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > GEFS > COLLABORATORS Home Operational Products Experimental Data ENSEMBLE FORECAST SYSTEM MSC NAEFS Products CPC NAEFS Experimental 8 to 14 Day Temperature Guidance CPC NAEFS Experimental 8 to 14 Day Precip Guidance NOAA / National Weather Service National Centers for

  12. Direct-coupled microcomputer-based building emulator for building energy management and control systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lam, H.N.

    1999-07-01

    In this paper, the development and implementation of a direct-coupled building emulator for a building energy management and control system (EMCS) is presented. The building emulator consists of a microcomputer and a computer model of an air-conditioning system implemented in a modular dynamic simulation software package for direct-coupling to an EMCS, without using analog-to-digital and digital-to-analog converters. The building emulator can be used to simulate in real time the behavior of the air-conditioning system under a given operating environment and subject to a given usage pattern. Software modules for data communication, graphical display, dynamic data exchange, and synchronization of simulationmore » outputs with real time have been developed to achieve direct digital data transfer between the building emulator and a commercial EMCS. Based on the tests conducted, the validity of the building emulator has been established and the proportional-plus-integral control function of the EMCS assessed.« less

  13. Using spread spectrum for AMR magnetic sensor

    NASA Astrophysics Data System (ADS)

    Vala, David

    2016-09-01

    This contribution describe invention of Magnetometer with protection against detection by electronic counter- measure (ECM) registered by Czech patent office as patent no. 305322.1 Magnetic sensors are often part of dual use or security instruments and equipment. For this purpose is very interesting to build sensor with is hidden against electronic countermeasure. In this case is very important level and behavior of electromagnetic noise produced by sensor. And also electromagnetic compatibility of electronic devices is the area which significant grows nowadays too. As the consequence of this growth there is a continuous process of making more strict standards focused on electromagnetic radiation of electronic devices. Sensors technology begins to be a part of these issues due sensors bandwidth increasing and approaching to frequency of radio communication band. Nowadays microcontrollers and similar digital circuits are integrated into sensors devices and it brings new sources of electromagnetic radiation in modern smart sensors.

  14. Strike action electromagnetic machine for immersion of rod elements into ground

    NASA Astrophysics Data System (ADS)

    Usanov, K. M.; Volgin, A. V.; Chetverikov, E. A.; Kargin, V. A.; Moiseev, A. P.; Ivanova, Z. I.

    2017-10-01

    During construction, survey work, and drilling shallow wells by striking, operations associated with dipping and removing the rod elements are the most common. At the same time relatively long, with small diameter, elements, in which the ratio of length to diameter l/d is 100 or more, constitute a significant proportion. At present, the application of power pulse linear electromagnetic motors to drive drum machines is recognized to be highly effective. However, the mechanical method of transmission of shocks does not allow dipping long longitudinally unstable core elements. In this case, mechanical energy must be transferred from the motor to the rod through its side surface. The design of the strike action electromagnetic machine with a through axial channel for non-mechanical end striking of the pile of long, longitudinally unstable metal rods is proposed. Electromagnetic striking machine for non-mechanical end striking rod elements provides operations characterized by ecological compatibility, safety and high quality.

  15. Magnetic field generated by lightning protection system

    NASA Astrophysics Data System (ADS)

    Geri, A.; Veca, G. M.

    1988-04-01

    A lightning protection system for today's civil buildings must be electromagnetically compatible with the electronic equipment present in the building. This paper highlights a mathematic model which analyzes the electromagnetic effects in the environment in which the lightning protection system is. This model is developed by means of finite elements of an electrical circuit where each element is represented by a double pole circuit according to the trapezoidal algorithm developed using the finite difference method. It is thus possible to analyze the electromagnetic phenomena associated with the transient effects created by the lightning stroke even for a high-intensity current. Referring to an elementary system comprised of an air terminal, a down conductor, and a ground terminal, numerical results are here laid out.

  16. Electromagnetic Compatibility Assessment of CCD Detector Acquisition Chains not Synchronized

    NASA Astrophysics Data System (ADS)

    Nicoletto, M.; Boschetti, D.; Ciancetta, E.; Maiorano, E.; Stagnaro, L.

    2016-05-01

    Euclid is a space observatory managed by the European Space Agency; it is the second medium class mission (see Figure 1) in the frame of Cosmic Vision 2015-2025 program.In the frame of this project, the electromagnetic interference between two different and not synchronized Charge Coupled Device (CCD) (see Figure 2) acquisition chains has been evaluated. The key parameter used for this assessment is the electromagnetic noise induced on each other. Taking into account the specificity of the issue, radiation coupling at relative low frequency and in near field conditions, classical approach based on simulations and testing on qualification model cannot be directly applied. Based on that, it has been decided to investigate the issue by test in an incremental way.

  17. Cryogenic scanning tunneling microscope with a magnetic coarse approach

    NASA Astrophysics Data System (ADS)

    Davydov, D. N.; Deltour, R.; Horii, N.; Timofeev, V. A.; Grokholski, A. S.

    1993-11-01

    A compact, rigid, and reliable cryogenic scanning tunneling microscope (CSTM) with a vertical electromagnetic coarse approach system was developed. This device can be used for topographic and local tunneling spectroscopy studies at liquid nitrogen and helium temperatures. Minimal step sizes of 28 nm for the electromagnetic translation device were achieved. The additional possibility of a coarse approach operation in the inertial slip-stick mode, without electromagnets, was successfully tested, making this STM compatible with external magnetic fields. A simple technique for characterizing the STM rigidity has been developed. Preliminary data, taken with this instrument are presented, demonstrating the achievement, at liquid helium temperature, of atomic resolution for topographic studies, and also the possibility of measuring simultaneously superconducting energy gap spectra.

  18. An isogeometric boundary element method for electromagnetic scattering with compatible B-spline discretizations

    NASA Astrophysics Data System (ADS)

    Simpson, R. N.; Liu, Z.; Vázquez, R.; Evans, J. A.

    2018-06-01

    We outline the construction of compatible B-splines on 3D surfaces that satisfy the continuity requirements for electromagnetic scattering analysis with the boundary element method (method of moments). Our approach makes use of Non-Uniform Rational B-splines to represent model geometry and compatible B-splines to approximate the surface current, and adopts the isogeometric concept in which the basis for analysis is taken directly from CAD (geometry) data. The approach allows for high-order approximations and crucially provides a direct link with CAD data structures that allows for efficient design workflows. After outlining the construction of div- and curl-conforming B-splines defined over 3D surfaces we describe their use with the electric and magnetic field integral equations using a Galerkin formulation. We use Bézier extraction to accelerate the computation of NURBS and B-spline terms and employ H-matrices to provide accelerated computations and memory reduction for the dense matrices that result from the boundary integral discretization. The method is verified using the well known Mie scattering problem posed over a perfectly electrically conducting sphere and the classic NASA almond problem. Finally, we demonstrate the ability of the approach to handle models with complex geometry directly from CAD without mesh generation.

  19. Instrument interface description for NOAA 2000 instruments with European morning spacecraft and/or NOAA-OPQ spacecraft

    NASA Technical Reports Server (NTRS)

    1993-01-01

    The purpose is to describe at a high level the common interface provisions and constraints placed on the NOAA-2000 instruments and the interfacing spacecraft elements in the following areas: electrical interface, mechanical interface, thermal interface, magnetic interface, electromagnetic compatibility, structural/mechanical environmental interface, contamination control, and the ionizing radiation environment. The requirements reflect the fact that these instruments must be compatible with a number of different polar orbiting satellite vehicles including the NOAA-OPQ satellites and the EUMETSAT METOP satellites.

  20. National Centers for Environmental Prediction

    Science.gov Websites

    Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post / VISION | About EMC EMC > Mesoscale Modeling > Home Mission Models R & D Collaborators Cyclone Tracks & Verification Implementation Info FAQ Disclaimer More Info MESOSCALE MODELING NOAA

  1. An Integrated Approach to Environmental Education: A Case Study

    ERIC Educational Resources Information Center

    du Preez, Nicolaas P.; Mohr-Swart, Maryna

    2004-01-01

    In 1994, the Executive Management Committee (EMC) of Technikon Pretoria took a strategic decision to develop educational programmes in environmental management and sustainable development. The EMC also decided to integrate these programmes with the development and implementation of an environmental management policy for Technikon Pretoria. This…

  2. EMCS Modules/Intelligent Time Clock (ITC).

    DTIC Science & Technology

    1980-09-01

    scale, smaller activities where a large EMCS would not be economically feasible, have had to look elsewhere to achieve their conservation goals. In this...DAEN- MPU . Washington DC: ERADCOM Tech Supp Dir. (DELSD-L) Ft. Monmouth, NJ: Engr District (Memphis) Library. Memphis TN: Natick (’en (Kwvoh flu

  3. National Centers for Environmental Prediction

    Science.gov Websites

    / VISION | About EMC EMC > GEFS > OPERATIONAL PRODUCTS Home Operational Products Experimental Data Global Ensemble products posted by the GEFS model team are experimental analysis and forecast products , and you will find them listed under the "Experimental Data" section of our web site. The

  4. Light-assisted drying (LAD) of small volume biologics: a comparison of two IR light sources

    NASA Astrophysics Data System (ADS)

    Young, Madison A.; Van Vorst, Matthew; Elliott, Gloria D.; Trammell, Susan R.

    2016-03-01

    Protein therapeutics have been developed to treat diseases ranging from arthritis and psoriasis to cancer. A challenge in the development of protein-based drugs is maintaining the protein in the folded state during processing and storage. We are developing a novel processing method, light-assisted drying (LAD), to dehydrate proteins suspended in a sugar (trehalose) solution for storage at supra-zero temperatures. Our technique selectively heats the water in small volume samples using near-IR light to speed dehydration which prevents sugar crystallization that can damage embedded proteins. In this study, we compare the end moisture content (EMC) as a function of processing time of samples dried with two different light sources, Nd:YAG (1064 nm) and Thulium fiber (1850 nm) lasers. EMC is the ratio of water to dry weight in a sample and the lower the EMC the higher the possible storage temperature. LAD with the 1064 and 1850 nm lasers yielded 78% and 65% lower EMC, respectively, than standard air-drying. After 40 minutes of LAD with 1064 and 1850 nm sources, EMCs of 0.27+/-.27 and 0.15+/-.05 gH2O/gDryWeight were reached, which are near the desired value of 0.10 gH2O/gDryWeight that enables storage in a glassy state without refrigeration. LAD is a promising new technique for the preparation of biologics for anhydrous preservation.

  5. Evaluation of the Eclipse eMC algorithm for bolus electron conformal therapy using a standard verification dataset.

    PubMed

    Carver, Robert L; Sprunger, Conrad P; Hogstrom, Kenneth R; Popple, Richard A; Antolak, John A

    2016-05-08

    The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent com-mercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC-calculated electron dose distributions for bolus ECT have been compared to previously measured TLD-dose points throughout patient-based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and < 0.2% statistical uncertainties. The accuracy of the dose calculations using moderate smoothing and no smooth-ing were evaluated. Dose differences (eMC-calculated less measured dose) were evaluated in terms of absolute dose difference, where 100% equals the given dose, as well as distance to agreement (DTA). Dose calculations were also evaluated for calculation speed. Results from the eMC for the retromolar trigone phantom using 1% statistical uncertainty without smoothing showed calculated dose at 89% (41/46) of the measured TLD-dose points was within 3% dose difference or 3 mm DTA of the measured value. The average dose difference was -0.21%, and the net standard deviation was 2.32%. Differences as large as 3.7% occurred immediately distal to the mandible bone. Results for the nose phantom, using 1% statistical uncertainty without smoothing, showed calculated dose at 93% (53/57) of the measured TLD-dose points within 3% dose difference or 3 mm DTA. The average dose difference was 1.08%, and the net standard deviation was 3.17%. Differences as large as 10% occurred lateral to the nasal air cavities. Including smoothing had insignificant effects on the accuracy of the retromolar trigone phantom calculations, but reduced the accuracy of the nose phantom calculations in the high-gradient dose areas. Dose calculation times with 1% statistical uncertainty for the retromolar trigone and nose treatment plans were 30 s and 24 s, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high-gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.

  6. Effects of Aperture Size on Q factor and Shielding Effectiveness of a Cubic Resonator

    NASA Astrophysics Data System (ADS)

    Parr, Stefan; Chromy, Stephan; Dickmann, Stefan; Schaarschmidt, Martin

    2017-09-01

    The EMC properties of a cubic metallic shield are highly affected by its resonances. At the resonant frequencies, the shielding effectiveness (SE) collapses, which results in high field strengths inside the cavity. This can cause failure or even breakdown of electronic devices inside the shield. The resonant behaviour is mainly determined by the quality or Q factor of the shield. In this paper, the effects of the aperture size on the Q factor and the SE of an electrically large, cubic shield are analysed. At first, a method is developed in order to determine the Q factor based on the resonance behaviour of the shield in time domain. Only the first resonance of the shield is considered therefore. The results are evaluated for different aperture diameters and compared with theory for the Q factor. The dominant coupling mechanism of electromagnetic energy into the shield is thus identified. Then the effect of aperture size on the SE is analysed. The excitation of resonances is very probable if the interfering signal is an ultrawideband (UWB) pulse, which constitutes a typical intentional electromagnetic interference (IEMI) scenario. Therefore, the relation between aperture size and SE is analysed using the theory of the transient SE for a broadband signal with a constant spectral density distribution. The results show, that a worst case aperture size exists, where the SE has its minimum.

  7. Measurement and optimization of the light collection uniformity in strongly tapered PWO crystals of the PANDA detector

    NASA Astrophysics Data System (ADS)

    Diehl, Stefan; Bremer, Daniel; Brinkmann, Kai-Thomas; Dormenev, Valery; Eissner, Tobias; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg; PANDA Collaboration

    2017-06-01

    The uniformity of the light collection is a crucial parameter for detectors based on inorganic scintillation crystals to guarantee a response proportional to the deposited energy. Especially in case of tapered crystals, like they are widely used to realize a 4π geometry of electromagnetic calorimeters (EMC) in high energy physics experiments, a strong non-uniformity is introduced by an additional focusing of the scintillation light due to the tapered geometry. The paper will discuss the determination and the reduction of the non-uniformity in strongly tapered lead tungstate crystals as used for the construction of the electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research (FAIR). Among different concepts for an uniformization a single de-polished lateral side face provided the optimum result with a remaining non-uniformity below 5% in good agreement with similar studies for the CMS ECAL at LHC. The impact on the achievable energy resolution in the energy regime of photons below 800 MeV is discussed in detail in comparison to GEANT4 simulations. The comparison of the response of two arrays with polished and de-polished crystals, respectively, shows in the latter case a significant improvement of the constant term of the parametrization of the energy resolution down to 0.5% accompanied by only very slight increase of the statistical term.

  8. National Centers for Environmental Prediction

    Science.gov Websites

    Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post / VISION | About EMC EMC > Mesoscale Modeling > IMPLEMENTATION INFO Home Mission Models R & D ; Extratropical Cyclone Tracks & Verification Implementation Info FAQ Disclaimer More Info MESOSCALE MODELING

  9. National Centers for Environmental Prediction

    Science.gov Websites

    Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post / VISION | About EMC EMC > Mesoscale Modeling > Home Mission Models R & D Collaborators Cyclone Tracks & Verification Implementation Info FAQ Disclaimer More Info MESOSCALE MODELING JUMP TO

  10. National Centers for Environmental Prediction

    Science.gov Websites

    Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post / VISION | About EMC EMC > Mesoscale Modeling > MODELS Home Mission Models R & D Collaborators Cyclone Tracks & Verification Implementation Info FAQ Disclaimer More Info MESOSCALE MODELING SREF

  11. National Centers for Environmental Prediction

    Science.gov Websites

    Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post / VISION | About EMC EMC > Mesoscale Modeling > CALENDAR Home Mission Models R & D Collaborators Cyclone Tracks & Verification Implementation Info FAQ Disclaimer More Info MESOSCALE MODELING CALENDAR

  12. National Centers for Environmental Prediction

    Science.gov Websites

    Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post / VISION | About EMC EMC > Mesoscale Modeling > R & D Home Mission Models R & D Collaborators Cyclone Tracks & Verification Implementation Info FAQ Disclaimer More Info MESOSCALE MODELING Air

  13. OBSERVATIONAL DATA PROCESSING AT NCEP

    Science.gov Websites

    operations, but also for research and study. 2. The various NCEP networks access the observational data base Statistics Observational Data Processing Data Assimilation Monsoon Desk Model Transition Seminars Seminar / VISION | About EMC Observational Data Processing at NCEP Dennis Keyser - NOAA/NWS/NCEP/EMC (Last Revised

  14. 75 FR 43555 - Hewlett Packard; Hewlett Packard-Enterprise Business Services Formerly Known as Electronic Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-26

    ... Workers From Sun Microsystems, Inc., Dell Computer Corp., EMC Corp., EMC Corp. Total, Cisco Systems Capital Corporation, Microsoft Corp., Symantec Corp., Xerox Corp., Vmware, Inc., Sun Microsystems Federal... known as Electronic Data Systems, including on- site leased workers from Sun Microsystems, Inc., Dell...

  15. 75 FR 63509 - Hewlett Packard, Hewlett Packard-Enterprise Business Services, Formerly Known as Electronic Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-15

    ... Workers From Sun Microsystems, Inc., Dell Computer Corp., EMC Corp., EMC Corp. Total, Cisco Systems Capital Corporation, Microsoft Corp., Symantec Corp., Xerox Corp., VMWare, Inc., Sun Microsystems Federal...-- Services, formerly known as Electronic Data Systems, including on- site leased workers from Sun...

  16. Electromagnetic Compatibility Testing of a Dedicated Short-Range Communication (DSRC) System That Conforms to the Japanese Standard.

    DOT National Transportation Integrated Search

    1998-11-01

    Dedicated short-range communication (DSRC) systems, designed to enhance the efficiency of highway travel, have been proposed for operation in the 5850- to 5925-MHz band. The successful operation of these communication systems depends upon their compa...

  17. NCEP Operational HWRF Forecasting System

    Science.gov Websites

    NOAA logo - Click to go to the NOAA homepage EMC Hurricane Team NWS logo - Click to go to the NWS © 2018 | NOAA * NWS * NCEP * EMC * Hurricane Project Team DISCLAIMER: THIS INFORMATION IS PROVIDED AS GUIDANCE. IT REQUIRES INTERPRETATION BY HURRICANE SPECIALISTS AND SHOULD NOT BE CONSIDERED AS A FINAL

  18. National Centers for Environmental Prediction

    Science.gov Websites

    Mailing Lists There are two listservs for the MTT group: announce and discuss To join the listservs go here: Announce - https://lstsrv.ncep.noaa.gov/mailman/listinfo/ncep.list.emc_porting-announce Discuss - https://lstsrv.ncep.noaa.gov/mailman/listinfo/ncep.list.emc_porting-discuss To email the lists: Announce

  19. NCEP SST Analysis

    Science.gov Websites

    Branches Global Climate & Weather Modeling Mesoscale Modeling Marine Modeling and Analysis Contact EMC Weather Service NWS logo - Click to go to the NWS homepage Environmental Modeling Center Home News Organization Search Go Search Polar Go MMAB SST Analysis Main page About MMAB Our Mission Our Personnel EMC

  20. EMC: Air Quality Forecast Home page

    Science.gov Websites

    archive NAM Verification Meteorology Error Time Series EMC NAM Spatial Maps Real Time Mesoscale Analysis Precipitation verification NAQFC VERIFICATION CMAQ Ozone & PM Error Time Series AOD Error Time Series HYSPLIT Smoke forecasts vs GASP satellite Dust and Smoke Error Time Series HYSPLIT WCOSS Upgrade (July

  1. Equilibrium Moisture Content of Common Fine Fuels in Southeastern Forests

    Treesearch

    W.H. Blackmarr

    1971-01-01

    Nine different kinds of forest litter found in ground fuel complexes of southeastern forests were subjected to step-wise changes in relative humidity to determine their equilibrium moisture content (EMC) at different levels of relative humidity. The adsorption and desorption EMC curves for these fuels exhibited the typical hysteresis loop...

  2. Effects of Solvent Composition on Liquid Range, Glass Transition, and Conductivity of Electrolytes of a (Li, Cs)PF 6 Salt in EC-PC-EMC Solvents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Michael S.; Li, Qiuyan; Li, Xing

    Electrolytes of 1 M LiPF 6 (lithium hexafluorophosphate) and 0.05 M CsPF 6 (cesium hexafluorophosphate) in EC-PC-EMC (ethylene carbonate-propylene carbonate-ethyl methyl carbonate) solvents of varying solvent compositions were studied for the effects of solvent composition on the lower limit of liquid range, viscosity (as reflected by the glass transition temperature), and electrolytic conductivity. In addition, a ternary phase diagram of EC-PC-EMC was constructed and crystallization temperatures of EC and EMC were calculated to assist the interpretation and understanding of the change of liquid range with solvent composition. A function based on Vogel-Fulcher-Tammann equation was fitted to the conductivity data inmore » their entirety and plotted as conductivity surfaces in solvent composition space for more direct and clear comparisons and discussions. Changes of viscosity and dielectric constant of the solvents with their composition, in relation to those of the solvent components, were found to be underlying many of the processes studied.« less

  3. 78 FR 27117 - General and Plastic Surgery Devices: Reclassification of Ultraviolet Lamps for Tanning...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-09

    ... sunlamp products are mechanically safe to prevent user injury. Mechanical safety testing, such as cyclic... off) are in proper working order. This requirement would mitigate increased skin cancer risk from... that sunlamp products are electrically safe and electromagnetically compatible in their intended use...

  4. Goldstone radio spectrum protection. [deep space network

    NASA Technical Reports Server (NTRS)

    Gaudian, B. A.; Cushman, R. B.

    1980-01-01

    Potential electromagnetic interference to the Goldstone tracking receivers due to neighboring military installations is discussed. Coordination of the military and NASA Goldstone activities in the Mojave Desert area is seen to be an effective method to protect the Goldstone radio spectrum while maintaining compatible operations for the military and Goldstone.

  5. Storm runoff quality and pollutant loading from commercial, residential, and industrial catchments in the tropic.

    PubMed

    Chow, M F; Yusop, Z; Shirazi, S M

    2013-10-01

    Information on the pollution level and the influence of hydrologic regime on the stormwater pollutant loading in tropical urban areas are still scarce. More local data are still required because rainfall and runoff generation processes in tropical environment are very different from the temperate regions. This study investigated the extent of urban runoff pollution in residential, commercial, and industrial catchments in the south of Peninsular Malaysia. Stormwater samples and flow rate data were collected from 51 storm events. Samples were analyzed for total suspended solids, 5-day biochemical oxygen demand, chemical oxygen demand, oil and grease (O&G), nitrate nitrogen (NO3-N), nitrite nitrogen, ammonia nitrogen, soluble reactive phosphorus, total phosphorus (TP), and zinc (Zn). It was found that the event mean concentrations (EMCs) of pollutants varied greatly between storm characteristics and land uses. The results revealed that site EMCs for residential catchment were lower than the published data but higher for the commercial and industrial catchments. All rainfall variables were negatively correlated with EMCs of most pollutants except for antecedent dry days (ADD). This study reinforced the earlier findings on the importance of ADD for causing greater EMC values with exceptions for O&G, NO3-N, TP, and Zn. In contrast, the pollutant loadings are influenced primarily by rainfall depth, mean intensity, and max 5-min intensity in all the three catchments. Overall, ADD is an important variable in multiple linear regression models for predicting the EMC values in the tropical urban catchments.

  6. Poster - Thur Eve - 45: Commissioning of the Varian ECLIPSE eMC algorithm for clinical electron treatment planning.

    PubMed

    Serban, M; Ruo, R; Sarfehnia, A; Parker, W; Evans, M

    2012-07-01

    Fast electron Monte Carlo systems have been developed commercially, and implemented for clinical practice in radiation therapy clinics. In this work the Varian eMC (electron Monte Carlo) algorithm was commissioned for clinical electron beams of energies between 6 MeV and 20 MeV. Beam outputs, PDDs and profiles were measured for 29 regular and irregular cutouts using the IC-10 (Wellhöfer) ionization chamber. Detailed percentage depth dose comparisons showed that the agreement between measurement and eMC for different characteristic points on the PDD are generally less than 1 mm and always less than 2 mm, with the eMC calculated values being lower than the measured values. Of the 145 measured output factors, 19 cases fail a ±2% agreement but only 8 cases fail a ±3% agreement between calculation and measurement. Comparison of central axis dose distributions for two electron energies (9, and 20 MeV) for a 10 × 10 cm 2 field, centrally shielded with Pb of width 0 cm (open), 1, 2 and 3 cm, shows agreement to within 3% except near the surface. Comparison of central axis dose distributions for 9 MeV in heterogeneous phantoms including bone and lung inserts showed agreement of 1 mm and 3 mm respectively with measured TLD data. The overall agreement between measurement and eMC calculation has enabled us to begin implementing this calculation model for clinical use. © 2012 American Association of Physicists in Medicine.

  7. Error mapping controller: a closed loop neuroprosthesis controlled by artificial neural networks.

    PubMed

    Pedrocchi, Alessandra; Ferrante, Simona; De Momi, Elena; Ferrigno, Giancarlo

    2006-10-09

    The design of an optimal neuroprostheses controller and its clinical use presents several challenges. First, the physiological system is characterized by highly inter-subjects varying properties and also by non stationary behaviour with time, due to conditioning level and fatigue. Secondly, the easiness to use in routine clinical practice requires experienced operators. Therefore, feedback controllers, avoiding long setting procedures, are required. The error mapping controller (EMC) here proposed uses artificial neural networks (ANNs) both for the design of an inverse model and of a feedback controller. A neuromuscular model is used to validate the performance of the controllers in simulations. The EMC performance is compared to a Proportional Integral Derivative (PID) included in an anti wind-up scheme (called PIDAW) and to a controller with an ANN as inverse model and a PID in the feedback loop (NEUROPID). In addition tests on the EMC robustness in response to variations of the Plant parameters and to mechanical disturbances are carried out. The EMC shows improvements with respect to the other controllers in tracking accuracy, capability to prolong exercise managing fatigue, robustness to parameter variations and resistance to mechanical disturbances. Different from the other controllers, the EMC is capable of balancing between tracking accuracy and mapping of fatigue during the exercise. In this way, it avoids overstressing muscles and allows a considerable prolongation of the movement. The collection of the training sets does not require any particular experimental setting and can be introduced in routine clinical practice.

  8. Error mapping controller: a closed loop neuroprosthesis controlled by artificial neural networks

    PubMed Central

    Pedrocchi, Alessandra; Ferrante, Simona; De Momi, Elena; Ferrigno, Giancarlo

    2006-01-01

    Background The design of an optimal neuroprostheses controller and its clinical use presents several challenges. First, the physiological system is characterized by highly inter-subjects varying properties and also by non stationary behaviour with time, due to conditioning level and fatigue. Secondly, the easiness to use in routine clinical practice requires experienced operators. Therefore, feedback controllers, avoiding long setting procedures, are required. Methods The error mapping controller (EMC) here proposed uses artificial neural networks (ANNs) both for the design of an inverse model and of a feedback controller. A neuromuscular model is used to validate the performance of the controllers in simulations. The EMC performance is compared to a Proportional Integral Derivative (PID) included in an anti wind-up scheme (called PIDAW) and to a controller with an ANN as inverse model and a PID in the feedback loop (NEUROPID). In addition tests on the EMC robustness in response to variations of the Plant parameters and to mechanical disturbances are carried out. Results The EMC shows improvements with respect to the other controllers in tracking accuracy, capability to prolong exercise managing fatigue, robustness to parameter variations and resistance to mechanical disturbances. Conclusion Different from the other controllers, the EMC is capable of balancing between tracking accuracy and mapping of fatigue during the exercise. In this way, it avoids overstressing muscles and allows a considerable prolongation of the movement. The collection of the training sets does not require any particular experimental setting and can be introduced in routine clinical practice. PMID:17029636

  9. Plane-wave scattering by self-complementary metasurfaces in terms of electromagnetic duality and Babinet's principle

    NASA Astrophysics Data System (ADS)

    Nakata, Yosuke; Urade, Yoshiro; Nakanishi, Toshihiro; Kitano, Masao

    2013-11-01

    We investigate theoretically electromagnetic plane-wave scattering by self-complementary metasurfaces. By using Babinet's principle extended to metasurfaces with resistive elements, we show that the frequency-independent transmission and reflection are realized for normal incidence of a circularly polarized plane wave onto a self-complementary metasurface, even if there is diffraction. Next, we consider two special classes of self-complementary metasurfaces. We show that self-complementary metasurfaces with rotational symmetry can act as coherent perfect absorbers, and those with translational symmetry compatible with their self-complementarity can split the incident power equally, even for oblique incidences.

  10. Designing Collaborative Developmental Standards by Refactoring of the Earth Science Models, Libraries, Workflows and Frameworks.

    NASA Astrophysics Data System (ADS)

    Mirvis, E.; Iredell, M.

    2015-12-01

    The operational (OPS) NOAA National Centers for Environmental Prediction (NCEP) suite, traditionally, consist of a large set of multi- scale HPC models, workflows, scripts, tools and utilities, which are very much depending on the variety of the additional components. Namely, this suite utilizes a unique collection of the in-house developed 20+ shared libraries (NCEPLIBS), certain versions of the 3-rd party libraries (like netcdf, HDF, ESMF, jasper, xml etc.), HPC workflow tool within dedicated (sometimes even vendors' customized) HPC system homogeneous environment. This domain and site specific, accompanied with NCEP's product- driven large scale real-time data operations complicates NCEP collaborative development tremendously by reducing chances to replicate this OPS environment anywhere else. The NOAA/NCEP's Environmental Modeling Center (EMC) missions to develop and improve numerical weather, climate, hydrological and ocean prediction through the partnership with the research community. Realizing said difficulties, lately, EMC has been taken an innovative approach to improve flexibility of the HPC environment by building the elements and a foundation for NCEP OPS functionally equivalent environment (FEE), which can be used to ease the external interface constructs as well. Aiming to reduce turnaround time of the community code enhancements via Research-to-Operations (R2O) cycle, EMC developed and deployed several project sub-set standards that already paved the road to NCEP OPS implementation standards. In this topic we will discuss the EMC FEE for O2R requirements and approaches in collaborative standardization, including NCEPLIBS FEE and models code version control paired with the models' derived customized HPC modules and FEE footprints. We will share NCEP/EMC experience and potential in the refactoring of EMC development processes, legacy codes and in securing model source code quality standards by using combination of the Eclipse IDE, integrated with the reverse engineering tools/APIs. We will also inform on collaborative efforts in the restructuring of the NOAA Environmental Modeling System (NEMS) - the multi- model and coupling framework, and transitioning FEE verification methodology.

  11. Ground Testing of the EMCS Seed Cassette for Biocompatibility with the Tardigrade, Hypsibius dujardini

    NASA Technical Reports Server (NTRS)

    Reinsch, Sigrid; Myers, Zachary Alan; DeSimone, Julia Carol; Freeman, John L.; Steele, Marianne K.; Sun, Gwo-Shing; Heathcote, David

    2014-01-01

    The European Modular Cultivation System, EMCS, was developed by ESA for plant experiments. We performed ground testing to determine whether ARC EMCS seed cassettes could be adapted for use with tardigrades for future spaceflight experiments. Tardigrades (water bears) are small invertebrates that enter the tun state in response to desiccation or other environmental stresses. Tardigrade tuns have suspended metabolism and have been shown to be survive exposure to space vacuum, high pressure, temperature and other stresses. For spaceflight experiments using the EMCS, the organisms ideally must be able to survive desiccation and storage in the cassette at ambient temperature for several weeks prior to the initiation of the experiment by the infusion of water to the cassette during spaceflight. The ability of tardigrades to survive extremes by entering the tun state make them ideal candidates for growth experiments in the EMCS cassettes. The growth substratum in the cassettes is a gridded polyether sulfone (PES) membrane. A blotter beneath the PES membrane contains dried growth medium. The goals of our study were to (1) determine whether tardigrades survive and reproduce on PES membranes, (2) develop a consistent method for dehydration of the tardigrades with high recovery rates upon rehydration, (3) to determine an appropriate food source for the tardigrades that can also be dehydrated/rehydrated and (4) successful mock rehydration experiment in cassettes with appropriate food source. We present results that show successful multigenerational growth of tardigrades on PES membranes with a variety of wet food sources. We have successfully performed a mock rehydration with tardigrades and at least one candidate food, protonema of the moss Polytrichum, that supports multigenerational growth and whose spores germinate quickly enough to match tardigrade feeding patterns post rehydration. Our results indicate that experiments on the ISS using the tardigrade, Hypsibius dujardini and other similar species could successfully be performed in the flight verified hardware of the EMCS seed cassettes.

  12. TSA suppresses miR-106b-93-25 cluster expression through downregulation of MYC and inhibits proliferation and induces apoptosis in human EMC.

    PubMed

    Zhao, Zhi-Ning; Bai, Jiu-Xu; Zhou, Qiang; Yan, Bo; Qin, Wei-Wei; Jia, Lin-Tao; Meng, Yan-Ling; Jin, Bo-Quan; Yao, Li-Bo; Wang, Tao; Yang, An-Gang

    2012-01-01

    Histone deacetylase (HDAC) inhibitors are emerging as a novel class of anti-tumor agents and have manifested the ability to decrease proliferation and increase apoptosis in different cancer cells. A significant number of genes have been identified as potential effectors responsible for the anti-tumor function of HDAC inhibitor. However, the molecular mechanisms of these HDAC inhibitors in this process remain largely undefined. In the current study, we searched for microRNAs (miRs) that were affected by HDAC inhibitor trichostatin (TSA) and investigated their effects in endometrial cancer (EMC) cells. Our data showed that TSA significantly inhibited the growth of EMC cells and induced their apoptosis. Among the miRNAs that altered in the presence of TSA, the miR-106b-93-25 cluster, together with its host gene MCM7, were obviously down-regulated in EMC cells. p21 and BIM, which were identified as target genes of miR-106b-93-25 cluster, increased in TSA treated tumor cells and were responsible for cell cycle arrest and apoptosis. We further identified MYC as a regulator of miR-106b-93-25 cluster and demonstrated its down-regulation in the presence of TSA resulted in the reduction of miR-106b-93-25 cluster and up-regulation of p21 and BIM. More important, we found miR-106b-93-25 cluster was up-regulated in clinical EMC samples in association with the overexpression of MCM7 and MYC and the down-regulation of p21 and BIM. Thus our studies strongly indicated TSA inhibited EMC cell growth and induced cell apoptosis and cell cycle arrest at least partially through the down-regulation of the miR-106b-93-25 cluster and up-regulation of it's target genes p21 and BIM via MYC.

  13. SU-F-T-74: Experimental Validation of Monaco Electron Monte Carlo Dose Calculation for Small Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varadhan; Way, S; Arentsen, L

    2016-06-15

    Purpose: To verify experimentally the accuracy of Monaco (Elekta) electron Monte Carlo (eMC) algorithm to calculate small field size depth doses, monitor units and isodose distributions. Methods: Beam modeling of eMC algorithm was performed for electron energies of 6, 9, 12 15 and 18 Mev for a Elekta Infinity Linac and all available ( 6, 10, 14 20 and 25 cone) applicator sizes. Electron cutouts of incrementally smaller field sizes (20, 40, 60 and 80% blocked from open cone) were fabricated. Dose calculation was performed using a grid size smaller than one-tenth of the R{sub 80–20} electron distal falloff distancemore » and number of particle histories was set at 500,000 per cm{sup 2}. Percent depth dose scans and beam profiles at dmax, d{sub 90} and d{sub 80} depths were measured for each cutout and energy with Wellhoffer (IBA) Blue Phantom{sup 2} scanning system and compared against eMC calculated doses. Results: The measured dose and output factors of incrementally reduced cutout sizes (to 3cm diameter) agreed with eMC calculated doses within ± 2.5%. The profile comparisons at dmax, d{sub 90} and d{sub 80} depths and percent depth doses at reduced field sizes agreed within 2.5% or 2mm. Conclusion: Our results indicate that the Monaco eMC algorithm can accurately predict depth doses, isodose distributions, and monitor units in homogeneous water phantom for field sizes as small as 3.0 cm diameter for energies in the 6 to 18 MeV range at 100 cm SSD. Consequently, the old rule of thumb to approximate limiting cutout size for an electron field determined by the lateral scatter equilibrium (E (MeV)/2.5 in centimeters of water) does not apply to Monaco eMC algorithm.« less

  14. Physics For Dummies

    NASA Astrophysics Data System (ADS)

    Holzner, Steve; Ph., D.

    2005-11-01

    The fun and easy way to understand the basic principles of physics How does gravity work? What does e=mc2 really mean? And what's a charm quark? Physics For Dummies answers these questions and more, explaining the basics of physical science and its importance in our everyday lives in a simple, clear, and entertaining fashion. Whether readers are taking a class, helping kids with homework, or are simply interested in how the world works, this plain-English guide gives them the knowledge they need to understand basic physics. Through real-world examples and problems, it covers such key topics as motion, energy, and waves (sound, light, wave-particle); solids, liquids, and gases; thermodynamics; electromagnetism; relativity; atomic and nuclear structures; and the Big Bang and stars. Steven Holzner, PhD (Ithaca, NY), is the author of more than 40 books and a former contributing editor at PC Magazine. He has been on the faculty of MIT and taught Physics 101 and 102 at Cornell for over ten years.

  15. Bio-soliton model that predicts non-thermal electromagnetic frequency bands, that either stabilize or destabilize living cells.

    PubMed

    Geesink, J H; Meijer, D K F

    2017-01-01

    Solitons, as self-reinforcing solitary waves, interact with complex biological phenomena such as cellular self-organization. A soliton model is able to describe a spectrum of electromagnetism modalities that can be applied to understand the physical principles of biological effects in living cells, as caused by endogenous and exogenous electromagnetic fields and is compatible with quantum coherence. A bio-soliton model is proposed, that enables to predict which eigen-frequencies of non-thermal electromagnetic waves are life-sustaining and which are, in contrast, detrimental for living cells. The particular effects are exerted by a range of electromagnetic wave eigen-frequencies of one-tenth of a Hertz till Peta Hertz that show a pattern of 12 bands, and can be positioned on an acoustic reference frequency scale. The model was substantiated by a meta-analysis of 240 published articles of biological electromagnetic experiments, in which a spectrum of non-thermal electromagnetic waves were exposed to living cells and intact organisms. These data support the concept of coherent quantized electromagnetic states in living organisms and the theories of Fröhlich, Davydov and Pang. It is envisioned that a rational control of shape by soliton-waves and related to a morphogenetic field and parametric resonance provides positional information and cues to regulate organism-wide systems properties like anatomy, control of reproduction and repair.

  16. Human coronavirus EMC does not require the SARS-coronavirus receptor and maintains broad replicative capability in mammalian cell lines.

    PubMed

    Müller, Marcel A; Raj, V Stalin; Muth, Doreen; Meyer, Benjamin; Kallies, Stephan; Smits, Saskia L; Wollny, Robert; Bestebroer, Theo M; Specht, Sabine; Suliman, Tasnim; Zimmermann, Katrin; Binger, Tabea; Eckerle, Isabella; Tschapka, Marco; Zaki, Ali M; Osterhaus, Albert D M E; Fouchier, Ron A M; Haagmans, Bart L; Drosten, Christian

    2012-12-11

    A new human coronavirus (hCoV-EMC) has emerged very recently in the Middle East. The clinical presentation resembled that of the severe acute respiratory syndrome (SARS) as encountered during the epidemic in 2002/2003. In both cases, acute renal failure was observed in humans. HCoV-EMC is a member of the same virus genus as SARS-CoV but constitutes a sister species. Here we investigated whether it might utilize angiotensin-converting enzyme 2 (ACE2), the SARS-CoV receptor. Knowledge of the receptor is highly critical because the restriction of the SARS receptor to deep compartments of the human respiratory tract limited the spread of SARS. In baby hamster kidney (BHK) cells, lentiviral transduction of human ACE2 (hACE2) conferred permissiveness and replication for SARS-CoV but not for hCoV-EMC. Monkey and human kidney cells (LLC-MK2, Vero, and 769-P) and swine kidney cells were permissive for both viruses, but only SARS-CoV infection could be blocked by anti-hACE2 antibody and could be neutralized by preincubation of virus with soluble ACE2. Our data show that ACE2 is neither necessary nor sufficient for hCoV-EMC replication. Moreover, hCoV-EMC, but not SARS-CoV, replicated in cell lines from Rousettus, Rhinolophus, Pipistrellus, Myotis, and Carollia bats, representing four major chiropteran families from both suborders. As human CoV normally cannot replicate in bat cells from different families, this suggests that hCoV-EMC might use a receptor molecule that is conserved in bats, pigs, and humans, implicating a low barrier against cross-host transmission. IMPORTANCE A new human coronavirus (hCoV) emerged recently in the Middle East. The disease resembled SARS (severe acute respiratory syndrome), causing a fatal epidemic in 2002/2003. Coronaviruses have a reservoir in bats and because this novel virus is related to SARS-CoV, we investigated whether it might replicate in bat cells and use the same receptor (angiotensin-converting enzyme 2 [ACE2]). This knowledge is highly critical, because the SARS-CoV receptor influenced pathology, and its localization in the deep respiratory tract is thought to have restricted the transmissibility of SARS. Our data show that hCoV-EMC does not need the SARS-CoV receptor to infect human cells. Moreover, the virus is capable of infecting human, pig, and bat cells. This is remarkable, as human CoVs normally cannot replicate in bat cells as a consequence of host adaptation. Our results implicate that the new virus might use a receptor that is conserved between bats, pigs and humans suggesting a low barrier against cross-host transmission.

  17. Fuel Injection Strategy for a Next Generation Pulse Detonation Engine

    DTIC Science & Technology

    2006-06-01

    at 45°C CE Approved EMC EMC Directive 89/336/EEC; EN 61326-1 Emissions and Immunity Safety Low Voltage Directive 73/23/EEC; EN 61010 -1...Operating Humidity 0–90% Nonoperating Humidity 0–100% CDRH Class IIIb IEC Class 3B From www.mellesgriot.com 47 SILICON OPTICAL SENSOR Model

  18. Teaching E=mc2: An Exploration of Some Issues.

    ERIC Educational Resources Information Center

    Baierlein, Ralph

    1991-01-01

    A discussion of what E=mc2 means and other issues associated with the equation are presented. The differences between matter, mass, and energy, a derivation of the equation, the history of the word mass and examples of how it is used, misconceptions surrounding the equation, and a discussion of uranium fission are included. (KR)

  19. Selective wave-transmitting electromagnetic absorber through composite metasurface

    NASA Astrophysics Data System (ADS)

    Sun, Zhiwei; Zhao, Junming; Zhu, Bo; Jiang, Tian; Feng, Yijun

    2017-11-01

    Selective wave-transmitting absorbers which have one or more narrow transmission bands inside a wide absorption band are often demanded in wireless communication and radome applications for reducing the coupling between different systems, improving anti-jamming capability, and reducing antennas' radar cross section. Here we propose a feasible method that utilizing composite of two metasurfaces with different polarization dependent characteristics, one works as electromagnetic polarization rotator and the other as a wideband polarization dependent electromagnetic wave absorber. The polarization rotator produces a cross polarization output in the wave-transmitting band, while preserves the polarization of the incidence outside the band. The metasurface absorber works for certain linear polarization with a much wider absorption band covering the wave-transmitting frequency. When combining these two metasurfaces properly, the whole structure behaves as a wideband absorber with a certain frequency transmission window. The proposal may be applied in radome designs to reduce the radar cross section of antenna or improving the electromagnetic compatibility in communication devices.

  20. Avionics system design for high energy fields: A guide for the designer and airworthiness specialist

    NASA Technical Reports Server (NTRS)

    Mcconnell, Roger A.

    1987-01-01

    Because of the significant differences in transient susceptibility, the use of digital electronics in flight critical systems, and the reduced shielding effects of composite materials, there is a definite need to define pracitices which will minimize electromagnetic susceptibility, to investigate the operational environment, and to develop appropriate testing methods for flight critical systems. The design practices which will lead to reduced electromagnetic susceptibility of avionics systems in high energy fields is described. The levels of emission that can be anticipated from generic digital devices. It is assumed that as data processing equipment becomes an ever larger part of the avionics package, the construction methods of the data processing industry will increasingly carry over into aircraft. In Appendix 1 tentative revisions to RTCA DO-160B, Environmental Conditions and Test Procedures for Airborne Equipment, are presented. These revisions are intended to safeguard flight critical systems from the effects of high energy electromagnetic fields. A very extensive and useful bibliography on both electromagnetic compatibility and avionics issues is included.

  1. Results of 2007 test beam of AMS-02 Electromagnetic Calorimeter

    NASA Astrophysics Data System (ADS)

    di Falco, Stefano

    2010-01-01

    The AMS-02 experiment will be delivered by the Space Shuttle Discovery to the ISS in summer 2010. The main goals of the experiment are search for antimatter and dark matter, high precision measurement of charged cosmic ray spectra and fluxes and study of gamma rays, in the GeV to TeV energy range. In AMS-02 the Electromagnetic Calorimeter (ECAL) is required to measure e+,e- and gamma energy and to discriminate electromagnetic showers from hadronic cascades. ECAL is based on a lead/scintillating fiber sandwich, providing a 3D imaging reconstruction of the showers. The electronics equipping the detector has low power consumption, low noise, large dynamic range readout and full double redundancy. The calorimeter successfully got through several space qualification tests concerning the mechanical and thermal stability, the electromagnetic compatibility and radiation hardness. The ECAL Flight Model was calibrated during Summer 2007 in a test beam at CERN, using 6-250 GeV electron and proton beams: angular and energy resolutions, obtained from these data, are reported.

  2. Intrasystem Analysis Program (IAP) Code Summaries.

    DTIC Science & Technology

    1983-05-01

    I - Ue’s Manual Engineering Section," RADC-TR-74-342, AD# A008526, December 1974. - 3. L. Bogdanor , R. A. Pearl--n, and M. .. Siegel, "Intrasystem...Electromagnetic Compatibility Analysis Program, Volume II - User’s Manual Usage Section," RADC-TR-74-342, AD# A008527, December 1974. i * J. L. Bogdanor

  3. [Role of an educational-and-methodological complex in the optimization of teaching at the stage of additional professional education of physicians in the specialty "anesthesiology and reanimatology"].

    PubMed

    Buniatian, A A; Sizova, Zh M; Vyzhigina, M A; Shikh, E V

    2010-01-01

    An educational-and-methodological complex (EMC) in the specialty 'Anesthesiology and Reanimatology", which promotes manageability, flexibility, and dynamism of an educational process, is of great importance in solving the problem in the systematization of knowledge and its best learning by physicians at a stage of additional professional education (APE). EMC is a set of educational-and-methodological materials required to organize and hold an educational process for the advanced training of anesthesiologists and resuscitation specialists at the stage of APE. EMC includes a syllabus for training in the area "Anesthesiology and Reanimatology" by the appropriate training pattern (certification cycles, topical advanced training cycles); a work program for training in the specialty "Anesthesiology and Reanimatology"; a work curriculums for training in allied specialties (surgery, traumatology and orthopedics, obstetrics and gynecology, and pediatrics); work programs on basic disciplines (pharmacology, normal and pathological physiology, normal anatomy, chemistry and biology); working programs on the area "Public health care and health care service", guidelines for the teacher; educational-and-methodological materials for the student; and quiz programs. The main point of EMC in the specialty "Anesthesiology and Reanimatology" is a work program. Thus, educational-and-methodological and teaching materials included into the EMC in the specialty 'Anesthesiology and Reanimatology" should envisage the logically successive exposition of a teaching material, the use of currently available methods and educational facilities, which facilitates the optimization of training of anesthesiologists and resuscitation specialists at the stage of APE.

  4. Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images.

    PubMed

    Shahriari, Navid; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak

    2015-11-01

    Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces the mortality rate. Therefore, suspicious lesions are tested for diagnosis by performing needle biopsy. In this paper, we have presented a novel computed tomography (CT)-compatible needle insertion device (NID). The NID is used to steer a flexible needle (φ0.55 mm) with a bevel at the tip in biological tissue. CT images and an electromagnetic (EM) tracking system are used in two separate scenarios to track the needle tip in three-dimensional space during the procedure. Our system uses a control algorithm to steer the needle through a combination of insertion and minimal number of rotations. Noise analysis of CT images has demonstrated the compatibility of the device. The results for three experimental cases (case 1: open-loop control, case 2: closed-loop control using EM tracking system and case 3: closed-loop control using CT images) are presented. Each experimental case is performed five times, and average targeting errors are 2.86 ± 1.14, 1.11 ± 0.14 and 1.94 ± 0.63 mm for case 1, case 2 and case 3, respectively. The achieved results show that our device is CT-compatible and it is able to steer a bevel-tipped needle toward a target. We are able to use intermittent CT images and EM tracking data to control the needle path in a closed-loop manner. These results are promising and suggest that it is possible to accurately target the lesions in real clinical procedures in the future.

  5. Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data.

    PubMed

    Shahriari, Navid; Heerink, Wout; van Katwijk, Tim; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak

    2017-07-01

    Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a straight path. In this work, we present a CT-compatible robotic system, which can both position the needle at the puncture point and also insert and rotate the needle. The robot has a remote-center-of-motion arm which is achieved through a parallel mechanism. A new needle steering scheme is also developed where CT images are fused with electromagnetic (EM) sensor data using an unscented Kalman filter. The data fusion allows us to steer the needle using the real-time EM tracker data. The robot design and the steering scheme are validated using three experimental cases. Experimental Case I and II evaluate the accuracy and CT-compatibility of the robot arm, respectively. In experimental Case III, the needle is steered towards 5 real targets embedded in an anthropomorphic gelatin phantom of the thorax. The mean targeting error for the 5 experiments is 1.78 ± 0.70 mm. The proposed robotic system is shown to be CT-compatible with low targeting error. Small nodule size and large needle diameter are two risk factors that can lead to complications in lung biopsy. Our results suggest that nodules larger than 5 mm in diameter can be targeted using our method which may result in lower complication rate. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Investigation of Historic Equilibrium Moisture Content Data from the Forest Products Laboratory

    Treesearch

    Samuel V. Glass; Samuel L. Zelinka; Jay A. Johnson

    2014-01-01

    The Forest Products Laboratory (FPL) has provided equilibrium moisture content (EMC) values of wood for given temperature and relative humidity (RH) conditions in various forms over the course of its history, primarily for practical purposes related to drying lumber and controlling moisture content. The FPL EMC data have been widely cited and reprinted, not only in...

  7. Frequent electronic media communication with friends is associated with higher adolescent substance use.

    PubMed

    Gommans, Rob; Stevens, Gonneke W J M; Finne, Emily; Cillessen, Antonius H N; Boniel-Nissim, Meyran; ter Bogt, Tom F M

    2015-02-01

    This study investigated the unique associations between electronic media communication (EMC) with friends and adolescent substance use (tobacco, alcohol, and cannabis), over and beyond the associations of face-to-face (FTF) interactions with friends and the average level of classroom substance use. Drawn from the cross-national 2009/2010 Health Behaviour in School-aged Children (HBSC) study in The Netherlands, 5,642 Dutch adolescents (Mage = 14.29) reported on their substance use, EMC, and FTF interactions. Two-level multilevel analyses (participants nested within classrooms) were run. Electronic media communication was positively associated with adolescent substance use, though significantly more strongly with alcohol (β = 0.15, SEβ = 0.02) than with tobacco (β = 0.05, SEβ = 0.02, t (5,180) = 3.33, p < 0.001) or cannabis use (β = 0.06, SEβ = 0.02, t (5,160) = 2.79, p < 0.01). Further, EMC strengthened several positive associations of FTF interactions and average classroom substance use with adolescent substance use. Electronic media communication was uniquely associated with substance use, predominantly with alcohol use. Thus, adolescents' EMC and other online behaviors should not be left unnoticed in substance use research and prevention programs.

  8. Exploring Sea Quark EMC Effect and Anti-Shadowing Through Drell-Yan at SeaQuest / Fermilab E906

    NASA Astrophysics Data System (ADS)

    Dannowitz, Bryan; Fermilab E906 / SeaQuest Collaboration

    2015-04-01

    Fermilab E906/SeaQuest is a fixed-target experiment that uses the 120 GeV Main Injector proton beam. SeaQuest will extract sea anti-quark structure of the proton by detecting dimuon pairs created by Drell-Yan and measuring the cross-section ratios for LH2, LD2, C, Fe, and W targets. The European Muon Collaboration (EMC) discovered that the momentum distribution of quarks in a free nucleon becomes modified when bound within a nucleus. In studying the EMC Effect, an anti-shadowing feature has been observed in DIS and pion-induced DY measurements in the 0 . 1

  9. Chemistry of green encapsulating molding compounds at interfaces with other materials in electronic devices

    NASA Astrophysics Data System (ADS)

    Scandurra, A.; Zafarana, R.; Tenya, Y.; Pignataro, S.

    2004-07-01

    The interface chemistry between encapsulating epoxy phenolic molding compound (EMC) containing phosphorous based organic flame retardant (the so called "green materials") and copper oxide-hydroxide and aluminum oxide-hydroxide surfaces have been studied in comparison with "conventional" EMC containing bromine and antimony as flame retardant. These green materials are designed to reduce the presence of toxic elements in the electronic packages and, consequently, in the environment. For the study were used a Scanning Acoustic Microscopy for delamination measurements, a dynamometer for the pull strength measurements and an ESCA spectrometer for chemical analysis of the interface. The general behavior of the green compound in terms of delamination, adhesion, and corrosion is found better or at least comparable than that of the conventional EMC.

  10. Multipole-Based Cable Braid Electromagnetic Penetration Model: Electric Penetration Case

    DOE PAGES

    Campione, Salvatore; Warne, Larry K.; Langston, William L.; ...

    2017-07-11

    In this paper, we investigate the electric penetration case of the first principles multipole-based cable braid electromagnetic penetration model reported in the Progress in Electromagnetics Research B 66, 63–89 (2016). We first analyze the case of a 1-D array of wires: this is a problem which is interesting on its own, and we report its modeling based on a multipole-conformal mapping expansion and extension by means of Laplace solutions in bipolar coordinates. We then compare the elastance (inverse of capacitance) results from our first principles cable braid electromagnetic penetration model to that obtained using the multipole-conformal mapping bipolar solution. Thesemore » results are found in a good agreement up to a radius to half spacing ratio of 0.6, demonstrating a robustness needed for many commercial cables. We then analyze realistic cable implementations without dielectrics and compare the results from our first principles braid electromagnetic penetration model to the semiempirical results reported by Kley in the IEEE Transactions on Electromagnetic Compatibility 35, 1–9 (1993). Finally, although we find results on the same order of magnitude of Kley's results, the full dependence on the actual cable geometry is accounted for only in our proposed multipole model which, in addition, enables us to treat perturbations from those commercial cables measured.« less

  11. Multipole-Based Cable Braid Electromagnetic Penetration Model: Electric Penetration Case

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campione, Salvatore; Warne, Larry K.; Langston, William L.

    In this paper, we investigate the electric penetration case of the first principles multipole-based cable braid electromagnetic penetration model reported in the Progress in Electromagnetics Research B 66, 63–89 (2016). We first analyze the case of a 1-D array of wires: this is a problem which is interesting on its own, and we report its modeling based on a multipole-conformal mapping expansion and extension by means of Laplace solutions in bipolar coordinates. We then compare the elastance (inverse of capacitance) results from our first principles cable braid electromagnetic penetration model to that obtained using the multipole-conformal mapping bipolar solution. Thesemore » results are found in a good agreement up to a radius to half spacing ratio of 0.6, demonstrating a robustness needed for many commercial cables. We then analyze realistic cable implementations without dielectrics and compare the results from our first principles braid electromagnetic penetration model to the semiempirical results reported by Kley in the IEEE Transactions on Electromagnetic Compatibility 35, 1–9 (1993). Finally, although we find results on the same order of magnitude of Kley's results, the full dependence on the actual cable geometry is accounted for only in our proposed multipole model which, in addition, enables us to treat perturbations from those commercial cables measured.« less

  12. Electromagnetic and thermal properties of three-dimensional printed multilayered nano-carbon/poly(lactic) acid structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paddubskaya, A.; Center for Physical Sciences and Technology, A. Goštauto 11, LT-01108 Vilnius; Valynets, N.

    A new type of light-weight material produced by 3D printing consisting of nano-carbon doped polymer layer followed by a dielectric polymer layer is proposed. We performed temperature dependent characterization and measured the electromagnetic (EM) response of the samples in the GHz and THz range. The temperature dependent structural characteristics, crystallization, and melting were observed to be strongly affected by the presence and the number of nano-carbon doped layers in the sandwich structure. The electromagnetic measurements show a great potential of such a type of periodic material for electromagnetic compatibility applications in microwave frequency range. Sandwich structures containing only two nano-carbonmore » layers already become not transparent to the microwaves, giving an electromagnetic interference shielding efficiency at the level of 8–15 dB. A sandwich consisting of one nano-carbon doped and one polymer layer is opaque for THz radiation, because of 80% of absorption. These studies serve as a basis for design and realization of specific optimal geometries of meta-surface type with the 3D printing technique, in order to reach a high level of electromagnetic interference shielding performance for real world EM cloaking and EM ecology applications.« less

  13. Investigation of space stable thermal control coating properties

    NASA Technical Reports Server (NTRS)

    Mookherji, T.

    1971-01-01

    A capability to study the nuclear magnetic resonance of spacecraft thermal control coating has been built utilizing an electromagnet and V-series and Wl-series electronics. The electronics associated with the electromagnet had to be modified to make it compatible with the resonance measuring system. Resonance measurements have been performed on ZnO, Zn2TiO4 and FEP Teflon. The failure to observe resonance in ZnO and Zn2TiO4 has been theoretically explained. The linewidth and second moment measurements on ultraviolet irradiated FEP Teflon showed that there was no measurable degradation of the material due to short term irradiation.

  14. Assessing the MR compatibility of dental retainer wires at 7 Tesla.

    PubMed

    Wezel, Joep; Kooij, Bert Jan; Webb, Andrew G

    2014-10-01

    To determine the MR compatibility of common dental retainer wires at 7 Tesla in terms of potential RF heating and magnetic susceptibility effects. Electromagnetic simulations and experimental results were compared for dental retainer wires placed in tissue-mimicking phantoms. Simulations were then performed for a human model with wire in place. Finally, image quality was assessed for different scanning protocols and wires. Simulations and experimental data in phantoms agreed well, with the length of the wire correlating to maximum heating in phantoms being approximately 47 mm. Even in this case, no substantial heating occurs when scanning within the specific absorption rate (SAR) guidelines for the head. Image distortions from the most ferromagnetic dental wire were not significant for any brain region. Dental retainer wires appear to be MR compatible at 7 Tesla. Copyright © 2013 Wiley Periodicals, Inc.

  15. Advanced Patient Data Replication and Recovery

    DTIC Science & Technology

    2010-10-01

    Patient Data Protection (APDAPT) Eisenhower Medical Center (EMC) is attempting to lower the risk of losing patient data, as well as the risk...includes radiological images. EMC has made a multi-million dollar investment in the digitization of patient data; the Electronic Medical Record (EMR...storage and retrieval of the patient chart or EMR. The EMR is comprised of patient vital signs, nurse notes, medications administered, doctors

  16. Randomized controlled study of early medication change for non-improvers to antidepressant therapy in major depression--The EMC trial.

    PubMed

    Tadić, André; Wachtlin, Daniel; Berger, Mathias; Braus, Dieter F; van Calker, Dietrich; Dahmen, Norbert; Dreimüller, Nadine; Engel, Alice; Gorbulev, Stanislav; Helmreich, Isabella; Kaiser, Anne-Katrin; Kronfeld, Kai; Schlicht, Konrad F; Tüscher, Oliver; Wagner, Stefanie; Hiemke, Christoph; Lieb, Klaus

    2016-04-01

    Patients with Major Depressive Disorder (MDD) and no improvement after two weeks of antidepressant pharmacotherapy have a high risk of treatment failure. The aim of the study was to determine whether an early medication change (EMC) strategy is superior to a guideline-based treatment in MDD patients without improvement after two weeks of antidepressant pharmacotherapy. Eight-hundred-and-eighty-nine patients with MDD were enrolled, 879 patients received the SSRI escitalopram. Of those, 192 patients had no improvement, defined as a reduction of < 20% on the Hamilton Depression Rating Scale (HAMD-17) after 14 days of treatment, and were randomly assigned to open treatment with the EMC strategy (n = 97; venlafaxine XR for study days 15-56; in case of sustained non-improvement on day 28, lithium augmentation for days 29-56) or TAU (n = 95; escitalopram continuation; non-responders on day 28 were switched to venlafaxine XR for four weeks, i.e. days 29-56). The primary outcome was remission (HAMD-17 ≤ 7) after 8 weeks of treatment as assessed by blinded raters. Remission rates were 24% for EMC and 16% for TAU, which was not significantly different (p = 0.2056). Sensitivity analyses for the primary and secondary effectiveness endpoints consistently showed favorable results for patients randomized to EMC. The results confirm data from post-hoc analyses of clinical trials showing that early non-improvement identifies patients who likely need alternate interventions. However, the herein used two-step switch/augmentation strategy for this risk group was not more effective than the control intervention. Alternate strategies and other design aspects are discussed in order to support researchers addressing the same research question. Copyright © 2016 Elsevier B.V. and ECNP. All rights reserved.

  17. The Light-Velocity Postulate: The Essential Difference between the Theories of Lorentz-Poincare and Einstein

    ERIC Educational Resources Information Center

    Abiko, Seiya

    2005-01-01

    Einstein, who had already developed the light-quantum theory, knew the inadequacy of Maxwell's theory in the microscopic sphere. Therefore, in writing his paper on special relativity, he had to set up the light-velocity postulate independently of the relativity postulate in order to make the electromagnetic foundation of physics compatible with…

  18. Automatic control in multidrive electrotechnical complexes with semiconductor converters

    NASA Astrophysics Data System (ADS)

    Vasilev, B. U.; Mardashov, D. V.

    2017-01-01

    The frequency convertor and the automatic control system, which can be used in the multi-drive electromechanical system with a few induction motions, are considered. The paper presents the structure of existing modern multi-drive electric drives inverters, namely, electric drives with a total frequency converter and few electric motions, and an electric drive, in which the converter is used for power supply and control of the independent frequency. It was shown that such technical solutions of frequency converters possess a number of drawbacks. The drawbacks are given. It was shown that the control of technological processes using the electric drive of this structure may be provided under very limited conditions, as the energy efficiency and the level of electromagnetic compatibility of electric drives is low. The authors proposed using a multi-inverter structure with an active rectifier in multidrive electric drives with induction motors frequency converters. The application of such frequency converter may solve the problem of electromagnetic compatibility, namely, consumption of sinusoidal currents from the network and the maintenance of a sinusoidal voltage and energy compatibility, namely, consumption of practically active energy from the network. Also, the paper proposes the use of the automatic control system, which by means of a multi-inverter frequency converter provides separate control of drive machines and flexible regulation of technological processes. The authors present oscillograms, which confirm the described characteristics of the developed electrical drive. The possible subsequent ways to improve the multi-motor drives are also described.

  19. Evaluation of Information Leakage from Cryptographic Hardware via Common-Mode Current

    NASA Astrophysics Data System (ADS)

    Hayashi, Yu-Ichi; Homma, Naofumi; Mizuki, Takaaki; Sugawara, Takeshi; Kayano, Yoshiki; Aoki, Takafumi; Minegishi, Shigeki; Satoh, Akashi; Sone, Hideaki; Inoue, Hiroshi

    This paper presents a possibility of Electromagnetic (EM) analysis against cryptographic modules outside their security boundaries. The mechanism behind the information leakage is explained from the view point of Electromagnetic Compatibility: electric fluctuation released from cryptographic modules can conduct to peripheral circuits based on ground bounce, resulting in radiation. We demonstrate the consequence of the mechanism through experiments where the ISO/IEC standard block cipher AES (Advanced Encryption Standard) is implemented on an FPGA board and EM radiations from power and communication cables are measured. Correlation Electromagnetic Analysis (CEMA) is conducted in order to evaluate the information leakage. The experimental results show that secret keys are revealed even though there are various disturbing factors such as voltage regulators and AC/DC converters between the target module and the measurement points. We also discuss information-suppression techniques as electrical-level countermeasures against such CEMAs.

  20. Electromagnetic characterization of strontium ferrite powders in series 2000, SU8 polymer

    NASA Astrophysics Data System (ADS)

    Sholiyi, Olusegun; Williams, John

    2014-12-01

    In this article, electromagnetic characterization of strontium hexaferrite powders and composites with SU8 was carried out to determine their compatibility with micro and millimeter wave fabrications. The structures of both powders and their composites were scanned with electron microscope to produce the SEM images. Two powder sizes (0.8-1.0 μm and 3-6 μm), were mixed with SU8, spin cast and patterned on wafer, and then characterized using energy dispersive x-ray spectrometry, ferromagnetic resonance (FMR) and vibrating sample magnetometry. In this investigation, FMRs of the samples were determined at 60 GHz while their complex permittivity and permeability were determined using rectangular waveguide method of characterization between 26.5 and 40 GHz frequency range. The results obtained show no adverse effects on the electromagnetic properties of the composites except some slight shift in the resonant frequencies due to anisotropic field of the samples.

  1. Mechanical modeling for magnetorheological elastomer isolators based on constitutive equations and electromagnetic analysis

    NASA Astrophysics Data System (ADS)

    Wang, Qi; Dong, Xufeng; Li, Luyu; Ou, Jinping

    2018-06-01

    As constitutive models are too complicated and existing mechanical models lack universality, these models are beyond satisfaction for magnetorheological elastomer (MRE) devices. In this article, a novel universal method is proposed to build concise mechanical models. Constitutive model and electromagnetic analysis were applied in this method to ensure universality, while a series of derivations and simplifications were carried out to obtain a concise formulation. To illustrate the proposed modeling method, a conical MRE isolator was introduced. Its basic mechanical equations were built based on equilibrium, deformation compatibility, constitutive equations and electromagnetic analysis. An iteration model and a highly efficient differential equation editor based model were then derived to solve the basic mechanical equations. The final simplified mechanical equations were obtained by re-fitting the simulations with a novel optimal algorithm. In the end, verification test of the isolator has proved the accuracy of the derived mechanical model and the modeling method.

  2. Magnetoplasma sheath waves on a conducting tether in the ionosphere with applications to EMI propagation on large space structures

    NASA Technical Reports Server (NTRS)

    Balmain, K. G.; James, H. G.; Bantin, C. C.

    1991-01-01

    A recent space experiment confirmed sheath-wave propagation of a kilometer-long insulated wire in the ionosphere, oriented parallel to the Earth's magnetic field. This space tether experiment, Oedipus-A, showed a sheath-wave passband up to about 2 MHz and a phase velocity somewhat slower than the velocity of light in a vacuum, and also demonstrated both ease of wave excitation and low attenuation. The evidence suggests that, on any large structure in low Earth orbit, transient or continuous wave electromagnetic interference, once generated, could propagate over the structure via sheath waves, producing unwanted signal levels much higher than in the absence of the ambient plasma medium. Consequently, there is a need for a review of both electromagnetic interference/electromagnetic compatibility standards and ground test procedures as they apply to large structures in low Earth orbit.

  3. Respiratory and intraperitoneal infection of mice with encephalomyocarditis virus: effect of sublethal x-irradiation on host resistance and survival

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bogaerts, W.J.C.; Durville-vanderoord, B.J.

    1975-01-01

    The relationships governing host resistance to viral infection were evaluated in mice following respiratory or peritoneal infection with three strains of encephalomyocarditis (EMC) virus, which were antigenically similar but differed in virulence. Host resistance to each strain was evaluated by determining the mean lethal dose LD50, and the mean infectious dose ID50. The contribution of non-specific resistance to the overall defense of the host was assessed in mice that had received 450 R of x irradiation prior to viral infection. Experimental results indicate that host capacity to resist respiratory infection exceeds that for peritoneal infection for the three EMC strains.more » It is concluded that respiratory inoculation of virus affords better immunization against EMC virus infection than does peritoneal infection. (Author) (GRA)« less

  4. Warpage of QFN Package in Post Mold Cure Process of integrated circuit packaging

    NASA Astrophysics Data System (ADS)

    Sriwithoon, Nattha; Ugsornrat, Kessararat; Srisuwitthanon, Warayoot; Thonglor, Panakamon

    2017-09-01

    This research studied about warpage of QFN package in post mold cure process of integrated circuit (IC) packages using pre-plated (PPF) leadframe. For IC package, epoxy molding compound (EMC) are molded by cross linking of compound stiffness but incomplete crosslinked network and leading the fully cured thermoset by post mold cure (PMC) process. The cure temperature of PMC can change microstructure of EMC in term of stress inside the package and effect to warpage of the package due to coefficient of thermal expansion (CTE) between EMC and leadframe. In experiment, cure temperatures were varied to check the effect of internal stress due to different cure temperature after completed post mold cure for TDFN 2×3 8L. The cure temperature were varied with 180 °C, 170 °C, 160 °C, and 150°C with cure time 4 and 6 hours, respectively. For analysis, the TDFN 2×3 8L packages were analyzed the warpage by thickness gauge and scanning acoustic microscope (SAM) after take the test samples out from the oven cure. The results confirmed that effect of different CTE between EMC and leadframe due to different cure temperature resulting to warpage of the TDFN 2×3 8L packages.

  5. [First flush effects of storm events of Baoxiang River in Lake Dianchi Watershed].

    PubMed

    Guo, Huai-Cheng; Xiang, Nan; Zhou, Feng; Wang, Yong-Hua; Li, Fa-Rong; Zhu, Xiang; Mao, Guo-Zhu; Yu, Shu-Xia; Li, Na; Sheng, Hu; Yang, Yong-Hui; He, Cheng-Jie; Wang, Cui-Yu

    2013-04-01

    To understand riverine process of non-point source effectively, first flush effects of storm events were investigated at Baoxiang River of Lake Dianchi Watershed. Three sampling stations were selected along Baoxiang River for observing the flow rate and pollutant concentrations of the first three storm events from June 2009 to August 2009. Net discharged volume, net discharged loading, and net event mean concentration (EMC(n)) were proposed with their calculation methods. According to the analysis of three storm events at three stations, the following results colcd be extracted: (1) the larger the percent of impervious land and population density were, the higher EMC(n) of TSS, TN, TP, permanganate index and their cumulative curves [M(V)] were along the river; (2) TSS, TP loadings as well as their M (V) were positively correlated to the storm intensity, while TN and permanganate index loadings were consistent with the total rainfall of each storm event, where the percent of NO3(-) -N in total nitrogen decreased gradually when the number of storm events increased; (3) compared to tradition EMC, EMC(n) was proven to be a better indicator to accurately uncover and magnify the differences in first flush effects of storm events among different stations or storm events.

  6. Comparison of the treatment performance of hybrid constructed wetlands treating stormwater runoff.

    PubMed

    Choi, J Y; Maniquiz-Redillas, M C; Hong, J S; Lee, S Y; Kim, L H

    2015-01-01

    This study was conducted to compare the treatment performance of two hybrid constructed wetlands (CWs) in treating stormwater runoff. The hybrid CWs were composed of a combination of free water surface (FWS) and horizontal subsurface flow (HSSF) CWs. Based on the results, strong correlation exists between potential runoff impacts and stormwater characteristics; however, the low correlations also suggest that not only the monitored parameters contribute to stormwater event mean concentrations (EMC) of pollutants, but other factors should also be considered as well. In the hydraulic and treatment performance of the hybrid CWs, a small surface area to catchment area (SA/CA) ratio, receiving a high concentration of influent EMC, will find it hard to achieve great removal efficiency; also a large SA/CA ratio, receiving low concentration of influent EMC, will find it hard to achieve great removal efficiency. With this, SA/CA ratio and influent characteristics such as EMC or load should be considered among the design factors of CWs. The performance data of the two CWs were used to consider the most cost-effective design of a hybrid CW. The optimum facility capacity (ratio of total runoff volume to storage volume) that is applicable for a target volume reduction and removal efficiency was provided in this study.

  7. Influences of rainfall variables and antecedent discharge on urban effluent concentrations and loads in wet weather.

    PubMed

    Xu, Zuxin; Xiong, Lijun; Li, Huaizheng; Liao, Zhengliang; Yin, Hailong; Wu, Jun; Xu, Jin; Chen, Hao

    2017-04-01

    For storm drainages inappropriately connected with sewage, wet weather discharge is a major factor that adversely affects receiving waters. A study of the wet weather influences of rainfall-discharge variables on storm drainages connected with sewage was conducted in the downtown Shanghai area (374 ha). Two indicators, event mean concentration (EMC) and event pollutant load per unit area (EPL), were used to describe the pollution discharge during 20 rain events. The study showed that the total rainfall and discharge volume were important factors that affect the EMCs and EPLs of the chemical oxygen demand, total phosphorus, and especially those of NH 4 + -N. The pollutant concentrations at the beginning of the discharge and the discharge period were also major factors that influence the EMCs of these three pollutants. Regression relationships between the rainfall-discharge variables and discharge volume/ EPLs (R 2 = 0.824-0.981) were stronger than the relationships between the rainfall-discharge variables and EMCs. These regression equations can be considered reliable in the system, with a relative validation error of less than ±10% for the discharge volume, and less than ±20% for the EPLs. The results presented in this paper provide guidance for effectively controlling pollution in similar storm drainages.

  8. Poynting Theorem, Relativistic Transformation of Total Energy-Momentum and Electromagnetic Energy-Momentum Tensor

    NASA Astrophysics Data System (ADS)

    Kholmetskii, Alexander; Missevitch, Oleg; Yarman, Tolga

    2016-02-01

    We address to the Poynting theorem for the bound (velocity-dependent) electromagnetic field, and demonstrate that the standard expressions for the electromagnetic energy flux and related field momentum, in general, come into the contradiction with the relativistic transformation of four-vector of total energy-momentum. We show that this inconsistency stems from the incorrect application of Poynting theorem to a system of discrete point-like charges, when the terms of self-interaction in the product {\\varvec{j}} \\cdot {\\varvec{E}} (where the current density {\\varvec{j}} and bound electric field {\\varvec{E}} are generated by the same source charge) are exogenously omitted. Implementing a transformation of the Poynting theorem to the form, where the terms of self-interaction are eliminated via Maxwell equations and vector calculus in a mathematically rigorous way (Kholmetskii et al., Phys Scr 83:055406, 2011), we obtained a novel expression for field momentum, which is fully compatible with the Lorentz transformation for total energy-momentum. The results obtained are discussed along with the novel expression for the electromagnetic energy-momentum tensor.

  9. Large-scale magnetic fields, non-Gaussianity, and gravitational waves from inflation

    NASA Astrophysics Data System (ADS)

    Bamba, Kazuharu

    2017-12-01

    We explore the generation of large-scale magnetic fields in the so-called moduli inflation. The hypercharge electromagnetic fields couple to not only a scalar field but also a pseudoscalar one, so that the conformal invariance of the hypercharge electromagnetic fields can be broken. We explicitly analyze the strength of the magnetic fields on the Hubble horizon scale at the present time, the local non-Gaussianity of the curvature perturbations originating from the massive gauge fields, and the tensor-to-scalar ratio of the density perturbations. As a consequence, we find that the local non-Gaussianity and the tensor-to-scalar ratio are compatible with the recent Planck results.

  10. Nonlinear System Analysis in Bipolar Integrated Circuits.

    DTIC Science & Technology

    1980-01-01

    H2 (fl,f 6), H2 (f2,f4), and H2 (f3,f4) are all equal, Equation (7-8) can be written as v M(t) = mA2 H2 (fl’-f 2) cos[27(f ,-f2)t] (7-9) The AF...and R. A. AMADORI: Micro- wave Interference Effect in Bipolar Transistors, IEEE Trans. EMC, Vol. EMC-17, pp. 216-219, November 1975. 55. KAPLAN , G

  11. Characterization of Stormwater Runoff from a Light Rail Transit Area.

    PubMed

    Sajjad, Raja Umer; Kim, Kyoung Jin; Memon, Sheeraz; Sukhbaatar, Chinzorig; Paule, Ma Cristina; Lee, Bum-Yeon; Lee, Chang-Hee

    2015-09-01

    The monitoring of stormwater runoff from Light Rail Transit (LRT) facilities is insufficient in many regions around the world. In this study, runoff quality and quantity were monitored during operational and non-operational LRT phases during 2010-2013. The event mean concentration (EMC) of pollutants showed little statistical variability during both phases. The antecedent dry day (ADD) showed a strong to moderate positive correlation with most pollutant EMCs during the non-operational phase. The existence and magnitude of the first flush from LRT runoff was found to be similar to those from other transportation land uses. The comparison of LRT runoff data with an adjacent road bridge site showed that the pollutant EMC and unit load were 2 to 9 times higher from the road bridge. It was suggested that LRT automated operation and the elevated track makes this transportation mode a viable option for the management of non-point source pollution.

  12. Suppression of Type-II Diabetes with Dyslipidemia and Nephropathy by Peels of Musa cavendish Fruit.

    PubMed

    Navghare, Vijay; Dhawale, Shashikant

    2016-10-01

    Musa cavendish, peels has local and traditional use to promote wound healing, hyperglycemia, ulceration etc. The present work investigated the lipid lowering; nephroprotective and glucose lowering properties of ethanolic extract of peels of Musa cavendish (EMC) in alloxan-induced diabetic rats. The EMC 250, 500 and 1000 mg/kg/day and the vehicle were administered orally to alloxan-induced diabetic rats (n = 6) for 3 weeks. Changes in plasma glucose, lipid profile along with kidney function before and after treatment with EMC were recorded. The ethanolic extract of peels of Musa cavendish reduced blood glucose, serum triglyceride, cholesterol, LDL cholesterol and creatinine levels and improvement in body weight, liver glycogen, serum HDL cholesterol, serum albumin and total protein level when compared with untreated rats. Musa cavendish has lipid lowering, nephroprotective and antidiabetic property by regulating glucose uptake in the liver and muscles by restoring the intracellular energy balance.

  13. Entry, Descent, and Landing Performance for a Mid-Lift-to-Drag Ratio Vehicle at Mars

    NASA Technical Reports Server (NTRS)

    Johnson, Breanna J.; Braden, Ellen M.; Sostaric, Ronald R.; Cerimele, Christopher J.; Lu, Ping

    2018-01-01

    In an effort to mature the design of the Mid-Lift-to-Drag ratio Rigid Vehicle (MRV) candidate of the NASA Evolvable Mars Campaign (EMC) architecture study, end-to-end six-degree-of-freedom (6DOF) simulations are needed to ensure a successful entry, descent, and landing (EDL) design. The EMC study is assessing different vehicle and mission architectures to determine which candidate would be best to deliver a 20 metric ton payload to the surface of Mars. Due to the large mass payload and the relatively low atmospheric density of Mars, all candidates of the EMC study propose to use Supersonic Retro-Propulsion (SRP) throughout the descent and landing phase, as opposed to parachutes, in order to decelerate to a subsonic touchdown. This paper presents a 6DOF entry-to-landing performance and controllability study with sensitivities to dispersions, particularly in the powered descent and landing phases.

  14. Plant Stem and Leaf Movements in Microgravity. Preliminary Results from a Study Using the EMCS Hardware on the ISS

    NASA Astrophysics Data System (ADS)

    Johnsson, Anders; Bokn Solheim, Bjarte Gees; Henning Iversen, Tor

    2008-06-01

    In the 72 days long MULTIGEN-1 experiment movements of Arabidopsis thaliana were recorded using the European Modular Cultivation System, EMCS. One main goal in the experiment was to study possible oscillatory movements of plant parts in weightlessness and under acceleration pulses on centrifuge rotors. Recording was made by video sampling of the plants in cultivation chambers every 5 min. The camera + mirror set-up in the EMCS was developed by alternating the mirror positions to get 'stereoscopic' 2D pictures so that 3D-movements could be constructed. Studies of rhythmic, helical movements of shoots as well as of rhythmic movements of leaves are discussed. It is concluded that gravity amplifies self-sustained circumnutations. Also gravitropical reactions of leaves were successfully documented. The results are of importance, for example in the discussion since Charles Darwin's days on the influence of gravity on circumnutations.

  15. Shuttle mission simulator baseline definition report, volume 2

    NASA Technical Reports Server (NTRS)

    Dahlberg, A. W.; Small, D. E.

    1973-01-01

    The baseline definition report for the space shuttle mission simulator is presented. The subjects discussed are: (1) the general configurations, (2) motion base crew station, (3) instructor operator station complex, (4) display devices, (5) electromagnetic compatibility, (6) external interface equipment, (7) data conversion equipment, (8) fixed base crew station equipment, and (9) computer complex. Block diagrams of the supporting subsystems are provided.

  16. Time-domain near-field/near-field transform with PWS operations

    NASA Astrophysics Data System (ADS)

    Ravelo, B.; Liu, Y.; Slama, J. Ben Hadj

    2011-03-01

    This article deals with the development of computation method dedicated to the extraction of the transient EM-near-field at certain distance from the given 2D data for the baseband application up to GHz. As described in the methodological analysis, it is based on the use of fft combined with the plane wave spectrum (PWS) operation. In order to verify the efficiency of the introduced method, a radiating source formed by the combination of electric dipoles excited by a short duration transient pulse current with a spectrum bandwidth of about 5 GHz is considered. It was shown that compared to the direct calculation, one gets the same behaviors of magnetic near-field components Hx, Hy and Hz with the presented extraction method, in the planes placed at {3 mm, 8 mm, 13 mm} of the initial reference plane. To confirm the relevance of the proposed transform, validation with a standard commercial tool was performed. In future, we envisage to exploit the proposed computation method to predict the transient electromagnetic (EM) field emissions notably in the microwave electronic devices for the EMC applications.

  17. Results of sub-analysis of a phase 2 study on trabectedin treatment for extraskeletal myxoid chondrosarcoma and mesenchymal chondrosarcoma.

    PubMed

    Morioka, Hideo; Takahashi, Shunji; Araki, Nobuhito; Sugiura, Hideshi; Ueda, Takafumi; Takahashi, Mitsuru; Yonemoto, Tsukasa; Hiraga, Hiroaki; Hiruma, Toru; Kunisada, Toshiyuki; Matsumine, Akihiko; Susa, Michiro; Nakayama, Robert; Nishimoto, Kazumasa; Kikuta, Kazutaka; Horiuchi, Keisuke; Kawai, Akira

    2016-07-14

    Trabectedin is reported to be particularly effective against translocation-related sarcoma. Recently, a randomized phase 2 study in patients with translocation-related sarcomas unresponsive or intolerable to standard chemotherapy was conducted, which showed clinical benefit of trabectedin compared with best supportive care (BSC). Extraskeletal myxoid chondrosarcoma (EMCS) and Mesenchymal chondrosarcoma (MCS) are very rare malignant soft tissue sarcomas, and are associated with translocations resulting in fusion genes. In addition, the previous in vivo data showed that trabectedin affect tumor necrosis and reduction in vascularization in a xenograft model of a human high-grade chondrosarcoma. The aim of the present analysis was to clarify the efficacy of trabectedin for EMCS and MCS subjects in the randomized phase 2 study. Five subjects with EMCS and MCS received trabectedin treatment in the randomized phase 2 study. Three MCS subjects were allocated to the BSC group. Objective response and progression-free survival (PFS) were assessed according to the Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1 by central radiology imaging review. The median follow-up time of the randomized phase 2 study was 22.7 months, and one subject with MCS was still receiving trabectedin treatment at the final data cutoff. The median PFS was 12.5 months (95 % CI: 7.4-not reached) in the trabectedin group, while 1.0 months (95 % CI: 0.3-1.0 months) in MCS subjects of the BSC group. The six-month progression-free rate was 100 % in the trabectedin group. One subject with MCS showed partial response, and the others in the trabectedin group showed stable disease. Overall survival of EMCS and MCS subjects was 26.4 months (range, 10.4-26.4 months) in the trabectedin group. At the final data cutoff, two of five subjects were still alive. This sub-analysis shows that trabectedin is effective for patients with EMCS and MCS compared with BSC. The efficacy results were better than previously reported data of TRS. These facts suggest that trabectedin become an important choice of treatment for patients with advanced EMCS or MCS who failed or were intolerable to standard chemotherapy. The randomized phase 2 study is registered with the Japan Pharmaceutical Information Center, number JapicCTI-121850 (May 31, 2012).

  18. Electromagnetic Extended Finite Elements for High-Fidelity Multimaterial Problems LDRD Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siefert, Christopher; Bochev, Pavel Blagoveston; Kramer, Richard Michael Jack

    Surface effects are critical to the accurate simulation of electromagnetics (EM) as current tends to concentrate near material surfaces. Sandia EM applications, which include exploding bridge wires for detonator design, electromagnetic launch of flyer plates for material testing and gun design, lightning blast-through for weapon safety, electromagnetic armor, and magnetic flux compression generators, all require accurate resolution of surface effects. These applications operate in a large deformation regime, where body-fitted meshes are impractical and multimaterial elements are the only feasible option. State-of-the-art methods use various mixture models to approximate the multi-physics of these elements. The empirical nature of these modelsmore » can significantly compromise the accuracy of the simulation in this very important surface region. We propose to substantially improve the predictive capability of electromagnetic simulations by removing the need for empirical mixture models at material surfaces. We do this by developing an eXtended Finite Element Method (XFEM) and an associated Conformal Decomposition Finite Element Method (CDFEM) which satisfy the physically required compatibility conditions at material interfaces. We demonstrate the effectiveness of these methods for diffusion and diffusion-like problems on node, edge and face elements in 2D and 3D. We also present preliminary work on h -hierarchical elements and remap algorithms.« less

  19. Energy Monitoring and Control Systems Operator Training - Recommended Qualifications, Staffing, Job Description, and Training Requirements for EMCS Operators.

    DTIC Science & Technology

    1982-06-01

    start/stop chiller optimization , and demand limiting were added. The system monitors a 7,000 ton chiller plant and controls 74 air handlers. The EMCS does...Modify analog limits. g. Adjust setpoints of selected controllers. h. Select manual or automatic control modes. i. Enable and disable individual points...or event schedules and controller setpoints ; make nonscheduled starts and stops of equipment or disable field panels when required for routine

  20. Development and Application of Compatible Discretizations of Maxwell's Equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, D; Koning, J; Rieben, R

    We present the development and application of compatible finite element discretizations of electromagnetics problems derived from the time dependent, full wave Maxwell equations. We review the H(curl)-conforming finite element method, using the concepts and notations of differential forms as a theoretical framework. We chose this approach because it can handle complex geometries, it is free of spurious modes, it is numerically stable without the need for filtering or artificial diffusion, it correctly models the discontinuity of fields across material boundaries, and it can be very high order. Higher-order H(curl) and H(div) conforming basis functions are not unique and we havemore » designed an extensible C++ framework that supports a variety of specific instantiations of these such as standard interpolatory bases, spectral bases, hierarchical bases, and semi-orthogonal bases. Virtually any electromagnetics problem that can be cast in the language of differential forms can be solved using our framework. For time dependent problems a method-of-lines scheme is used where the Galerkin method reduces the PDE to a semi-discrete system of ODE's, which are then integrated in time using finite difference methods. For time integration of wave equations we employ the unconditionally stable implicit Newmark-Beta method, as well as the high order energy conserving explicit Maxwell Symplectic method; for diffusion equations, we employ a generalized Crank-Nicholson method. We conclude with computational examples from resonant cavity problems, time-dependent wave propagation problems, and transient eddy current problems, all obtained using the authors massively parallel computational electromagnetics code EMSolve.« less

  1. Analysis and predictive models of stormwater runoff volumes, loads, and pollutant concentrations from watersheds in the Twin Cities metropolitan area, Minnesota, USA.

    PubMed

    Brezonik, Patrick L; Stadelmann, Teresa H

    2002-04-01

    Urban nonpoint source pollution is a significant contributor to water quality degradation. Watershed planners need to be able to estimate nonpoint source loads to lakes and streams if they are to plan effective management strategies. To meet this need for the twin cities metropolitan area, a large database of urban and suburban runoff data was compiled. Stormwater runoff loads and concentrations of 10 common constituents (six N and P forms, TSS, VSS, COD, Pb) were characterized, and effects of season and land use were analyzed. Relationships between runoff variables and storm and watershed characteristics were examined. The best regression equation to predict runoff volume for rain events was based on rainfall amount, drainage area, and percent impervious area (R2 = 0.78). Median event-mean concentrations (EMCs) tended to be higher in snowmelt runoff than in rainfall runoff, and significant seasonal differences were found in yields (kg/ha) and EMCs for most constituents. Simple correlations between explanatory variables and stormwater loads and EMCs were weak. Rainfall amount and intensity and drainage area were the most important variables in multiple linear regression models to predict event loads, but uncertainty was high in models developed with the pooled data set. The most accurate models for EMCs generally were found when sites were grouped according to common land use and size.

  2. Primary epithelial-myoepithelial carcinoma of the lung: A case report demonstrating high-grade transformation-like changes.

    PubMed

    Tajima, Shogo; Aki, Michihiko; Yajima, Kiyoshige; Takahashi, Tsuyoshi; Neyatani, Hiroshi; Koda, Kenji

    2015-07-01

    Primary salivary gland-type tumors of the lung are rare; among them, epithelial-myoepithelial carcinomas (EMC) represent a minor histological subtype. The present case documents an EMC that occluded the B8 segment of the left lung in a 72-year-old woman. Macroscopically, the tumor was well-demarcated; however, microscopic examination demonstrated that it had infiltrated the lung parenchyma. The majority of the tumor mass was composed of a myoepithelial overgrowth in conjunction with conventional bilayered ductal structures comprising epithelial and myoepithelial cells. At the advancing edge of the tumor, the myoepithelial overgrowth was observed to be gradually transitioning to a higher-grade component, which demonstrated venous invasion. The Ki-67 labeling index was reduced compared with high-grade transformation (HGT) of salivary gland EMC; p53 was sparsely observed on immunostaining. However, cyclin D1, which is reported to be overexpressed in certain subtypes of salivary gland carcinomas with HGT, was overexpressed in the higher-grade component of the tumor, indicating a potential HGT initiation. The surgical margin was tumor free, and no recurrence has been observed for 4 months. A thorough follow-up is required considering the HGT-like changes and venous invasion of the tumor. Additional studies are required to elucidate the characteristics of pulmonary EMC, with an emphasis on detecting HGT or HGT-like changes.

  3. Evolutionary modification of mesenchyme cells in sand dollars in the transition from indirect to direct development.

    PubMed

    Yajima, Mamiko

    2007-01-01

    Peronella japonica, an intermediate type of direct-developing sand dollar, forms an abbreviated pluteus, followed by metamorphosis within 3 days without feeding. In this species, ingression of mesenchyme cells starts before hatching and continues until gastrulation, but no typical secondary mesenchyme cells (SMCs) migrate from the tip of the archenteron. Here, I investigated the cell lineage of mesenchyme cells through metamorphosis in P. japonica and found that mesenchyme cells migrating before hatching (early mesenchyme cells [EMCs]) were exclusively derived from micromeres and became larval skeletogenic cells, whereas cells migrating after hatching (late mesenchyme cells [LMCs]) appeared to contain several nonskeletogenic cells. Thus, it is likely that EMCs are homologous to primary mesenchyme cells (PMCs) and LMCs are similar to the SMCs of typical indirect developers, suggesting that heterochrony in the timing of mesenchyme cell ingression may have occurred in this species. EMCs disappeared after metamorphosis and LMCs were involved in adult skeletogenesis. Embryos from which micromeres were removed at the 16-cell stage formed armless plutei that went on to form adult skeletons and resulted in juveniles with normal morphology. These results suggest that in P. japonica, LMCs form adult skeletal elements, whereas EMCs are specialized for larval spicule formation. The occurrence of evolutionary modifications in mesenchyme cells in the transition from indirect to direct development of sand dollars is discussed.

  4. Managing for the next big thing. Interview by Paul Hemp.

    PubMed

    Ruettgers, M

    2001-01-01

    In this HBR interview, CEO Michael Ruettgers speaks in detail about the managerial practices that have allowed EMC to anticipate and exploit disruptive technologies, market opportunities, and business models ahead of its competitors. He recounts how the company repeatedly ventured into untested markets, ultimately transforming itself from a struggling maker of minicomputer memory boards into a data storage powerhouse and one of the most successful companies of the past decade. The company has achieved sustained and nearly unrivaled revenue, profit, and shareprice growth through a number of means. Emphasizing timing and speed, Ruettgers says, is critical. That's meant staggering products rather than developing them sequentially and avoiding the excessive refinements that slow time to market. Indeed, a sense of urgency, Ruettgers explains, has been critical to EMC's success. Processes such as quarterly goal setting and monthly forecasting meetings help maintain a sense of urgency and allow managers to get early glimpses of changes in the market. So does an environment in which personal accountability is stressed and the corporate focus is single-minded. Perhaps most important, the company has procedures to glean insights from customers. Intensive forums involving EMC engineers and leading-edge customers, who typically push for unconventional solutions to their problems, often yield new product features. Similarly, a customer service system that includes real-time monitoring of product use enables EMC to understand customer needs firsthand.

  5. Ground Testing of the EMCS Seed Cassette for Biocompatibility with the Cellular Slime Mold, Dictyostelium Discoideum

    NASA Technical Reports Server (NTRS)

    Hanely, Julia C.; Reinsch, Sigrid; Myers, Zachary A.; Freeman, John; Steele, Marianne K.; Sun, Gwo-Shing; Heathcote, David G.

    2014-01-01

    The European Modular Cultivation System, EMCS, was developed by ESA for plant experiments. To expand the use of flight verified hardware for various model organisms, we performed ground experiments to determine whether ARC EMCS Seed Cassettes could be adapted for use with cellular slime mold for future space flight experiments. Dictyostelium is a cellular slime mold that can exist both as a single-celled independent organism and as a part of a multicellular colony which functions as a unit (pseudoplasmodium). Under certain stress conditions, individual amoebae will aggregate to form multicellular structures. Developmental pathways are very similar to those found in Eukaryotic organisms, making this a uniquely interesting organism for use in genetic studies. Dictyostelium has been used as a genetic model organism for prior space flight experiments. Due to the formation of spores that are resistant to unfavorable conditions such as desiccation, Dictyostelium is also a good candidate for use in the EMCS Seed Cassettes. The growth substratum in the cassettes is a gridded polyether sulfone (PES) membrane. A blotter beneath the PES membranes contains dried growth medium. The goals of this study were to (1) verify that Dictyostelium are capable of normal growth and development on PES membranes, (2) develop a method for dehydration of Dictyostelium spores with successful recovery and development after rehydration, and (3) successful mock rehydration experiments in cassettes. Our results show normal developmental progression in two strains of Dictyostelium discoideum on PES membranes with a bacterial food source. We have successfully performed a mock rehydration of spores with developmental progression from aggregation to slug formation, and production of morphologically normal spores within 9 days of rehydration. Our results indicate that experiments on the ISS using the slime mold, Dictyostelium discoideum could potentially be performed in the flight verified hardware of the EMCS ARC Seed Cassettes.

  6. [Total pollution features of urban runoff outlet for urban river].

    PubMed

    Luo, Hong-Bing; Luo, Lin; Huang, Gu; He, Qiang; Liu, Ping

    2009-11-01

    The urban stormwater runoff discharged to urban river, especially to rainfall source river, cannot be ignored. In this study, the Futian River watershed in Shenzhen city in a typical southern city of China is taken as the research object. In order to guide the pollution control for urban river, the eighteen rainfall events were monitored, and the total pollution features of the urban runoff outlet for this urban river were analyzed and discussed by using the process of pollutographs, the identifying to first flush, event mean concentration (EMC), etc. Results show that the concentrations of COD, SS, TN, TP and BOD5 are ten times more than the grade V of the environmental quality standards for surface water during the runoff time; the pollution caused by heavy metals (Cr, Ge, Cu, Hg and As) in runoff at a typical rainfall event is serious; the average and range of pollutant concentration at this runoff outlet in study area are evidently higher than at Shapingba in Chongqing city of China and at Silerwood in Canada, but are lower than at Shilipu in Wuhan city of China. The first flushes of COD, SS, BOD5, especially COD and SS, are evident, but the TN and TP are not. The average EMC of COD, TN, TP and BOD5 are 224.14, 571.15, 5.223, 2.04, 143.5 mg/L, respectively. To some extent, the EMC of COD is about two times of the value of the near cities, Macao and Zhuhai. The EMC of TN and TP are obviously higher than Beijing, Guangzhou and Shanghai. To compared with foreign counties, the EMC of the study area in Shenzhen is obviously much higher than the cities of Korean, USA and Canada. So the total pollution caused by the urban surface runoff in study area is serious and necessary to be treated.

  7. Effects of long-term estrogen replacement therapy on bone turnover in periarticular tibial osteophytes in surgically postmenopausal cynomolgus monkeys

    PubMed Central

    Olson, Erik J.; Lindgren, Bruce R.; Carlson, Cathy S.

    2008-01-01

    The aims of the present study were to assess the effects of long-term estrogen replacement therapy (ERT) on size and indices of bone turnover in periarticular osteophytes in ovariectomized cynomolgus monkeys and to compare dynamic indices of bone turnover in osteophyte bone with those of subchondral bone (SCB) and epiphyseal/metaphyseal cancellous (EMC) bone. One hundred sixty-five adult female cynomolgus macaques were bilaterally ovariectomized and randomly divided into three age- and weight-matched treatment groups for a 36-month treatment period. Group 1 (OVX control) received no treatment, Group 2 (SPE) received soy phytoestrogens, and Group 3 (ERT) received conjugated equine estrogens in the diet; all monkeys were labeled with calcein before necropsy. A midcoronal, plastic-embedded section of the right proximal tibia from 20 randomly selected animals per treatment group was examined histologically. Forty-nine of the sections (OVX control, n=16; SPE, n=16; ERT, n=17) contained lateral abaxial osteophytes, and static and dynamic histomorphometry measurements were taken from osteophyte bone, SCB from the lateral tibial plateau, and EMC bone. Data were analyzed using the ANOVA and Kruskal-Wallis test, correlation and regression methods, and the Friedman and Wilcoxon signed rank test. There was no significant effect of long-term ERT on osteophyte area or on any static or dynamic histomorphometry parameters. The bone volume, trabecular number, and trabecular thickness in osteophyte bone were considerably higher than in EMC bone; whereas, trabecular separation was considerably lower in osteophyte bone. In all three treatment groups, BS/BV was significantly lower in osteophyte bone vs. EMC bone and significantly higher in osteophyte bone vs. lateral SCB. We conclude that osteophyte area and static and dynamic histomorphometry parameters within periarticular tibial osteophytes in ovariectomized cynomolgus monkeys are not significantly influenced by long-term ERT, but that site differences in static and dynamic bone histomorphometry parameters exist, particularly between EMC and osteophyte bone. PMID:18291743

  8. Effects of long-term estrogen replacement therapy on bone turnover in periarticular tibial osteophytes in surgically postmenopausal cynomolgus monkeys.

    PubMed

    Olson, Erik J; Lindgren, Bruce R; Carlson, Cathy S

    2008-05-01

    The aims of the present study were to assess the effects of long-term estrogen replacement therapy (ERT) on size and indices of bone turnover in periarticular osteophytes in ovariectomized cynomolgus monkeys and to compare dynamic indices of bone turnover in osteophyte bone with those of subchondral bone (SCB) and epiphyseal/metaphyseal cancellous (EMC) bone. One hundred sixty-five adult female cynomolgus macaques were bilaterally ovariectomized and randomly divided into three age- and weight-matched treatment groups for a 36-month treatment period. Group 1 (OVX control) received no treatment, Group 2 (SPE) received soy phytoestrogens, and Group 3 (ERT) received conjugated equine estrogens in the diet; all monkeys were labeled with calcein before necropsy. A midcoronal, plastic-embedded section of the right proximal tibia from 20 randomly selected animals per treatment group was examined histologically. Forty-nine of the sections (OVX control, n=16; SPE, n=16; ERT, n=17) contained lateral abaxial osteophytes, and static and dynamic histomorphometry measurements were taken from osteophyte bone, SCB from the lateral tibial plateau, and EMC bone. Data were analyzed using the ANOVA and Kruskal-Wallis test, correlation and regression methods, and the Friedman and Wilcoxon signed rank test. There was no significant effect of long-term ERT on osteophyte area or on any static or dynamic histomorphometry parameters. The bone volume, trabecular number, and trabecular thickness in osteophyte bone were considerably higher than in EMC bone; whereas, trabecular separation was considerably lower in osteophyte bone. In all three treatment groups, BS/BV was significantly lower in osteophyte bone vs. EMC bone and significantly higher in osteophyte bone vs. lateral SCB. We conclude that osteophyte area and static and dynamic histomorphometry parameters within periarticular tibial osteophytes in ovariectomized cynomolgus monkeys are not significantly influenced by long-term ERT, but that site differences in static and dynamic bone histomorphometry parameters exist, particularly between EMC and osteophyte bone.

  9. EMP and HPM Suppression Techniques

    DTIC Science & Technology

    1997-03-10

    34 IEEE International Electromagnetic Compatibility Symposium, Anaheim, California (1993). 6 Jerry Behling. 7 Karen Shrier . 8 Dutcher, Clinton...York (1972). II-A-3-16 II-R REFERENCES SELECTED BIBLIOGRAPHY [I] Hyatt, H. M.; Shrier , K. P., "Electrical Overstress Pulse Protection Material...EI-11(2) (1976). [19] Böhm, David , "Quantum Theory," Prentice-Hall, New Jersey (1951). [20] Dutcher, Clinton, "Vector Space Quantum Formalism

  10. An Improved High-Sensitivity Airborne Transient Electromagnetic Sensor for Deep Penetration

    PubMed Central

    Chen, Shudong; Guo, Shuxu; Wang, Haofeng; He, Miao; Liu, Xiaoyan; Qiu, Yu; Zhang, Shuang; Yuan, Zhiwen; Zhang, Haiyang; Fang, Dong; Zhu, Jun

    2017-01-01

    The investigation depth of transient electromagnetic sensors can be effectively increased by reducing the system noise, which is mainly composed of sensor internal noise, electromagnetic interference (EMI), and environmental noise, etc. A high-sensitivity airborne transient electromagnetic (AEM) sensor with low sensor internal noise and good shielding effectiveness is of great importance for deep penetration. In this article, the design and optimization of such an AEM sensor is described in detail. To reduce sensor internal noise, a noise model with both a damping resistor and a preamplifier is established and analyzed. The results indicate that a sensor with a large diameter, low resonant frequency, and low sampling rate will have lower sensor internal noise. To improve the electromagnetic compatibility of the sensor, an electromagnetic shielding model for a central-tapped coil is established and discussed in detail. Previous studies have shown that unclosed shields with multiple layers and center grounding can effectively suppress EMI and eddy currents. According to these studies, an improved differential AEM sensor is constructed with a diameter, resultant effective area, resonant frequency, and normalized equivalent input noise of 1.1 m, 114 m2, 35.6 kHz, and 13.3 nV/m2, respectively. The accuracy of the noise model and the shielding effectiveness of the sensor have been verified experimentally. The results show a good agreement between calculated and measured results for the sensor internal noise. Additionally, over 20 dB shielding effectiveness is achieved in a complex electromagnetic environment. All of these results show a great improvement in sensor internal noise and shielding effectiveness. PMID:28106718

  11. Vehicle Fault Diagnose Based on Smart Sensor

    NASA Astrophysics Data System (ADS)

    Zhining, Li; Peng, Wang; Jianmin, Mei; Jianwei, Li; Fei, Teng

    In the vehicle's traditional fault diagnose system, we usually use a computer system with a A/D card and with many sensors connected to it. The disadvantage of this system is that these sensor can hardly be shared with control system and other systems, there are too many connect lines and the electro magnetic compatibility(EMC) will be affected. In this paper, smart speed sensor, smart acoustic press sensor, smart oil press sensor, smart acceleration sensor and smart order tracking sensor were designed to solve this problem. With the CAN BUS these smart sensors, fault diagnose computer and other computer could be connected together to establish a network system which can monitor and control the vehicle's diesel and other system without any duplicate sensor. The hard and soft ware of the smart sensor system was introduced, the oil press, vibration and acoustic signal are resampled by constant angle increment to eliminate the influence of the rotate speed. After the resample, the signal in every working cycle could be averaged in angle domain and do other analysis like order spectrum.

  12. Understanding reverberating chambers as an alternative facility for EMC testing

    NASA Astrophysics Data System (ADS)

    Ma, M. T.

    A relatively new facility called a reverberating chamber designed for EMC testing is described. The purpose is to create a statistically uniform electric field inside a metal enclosure for testing radiated susceptibility or immunity of equipment. Design criteria in terms of the number of cavity modes, mode density, and composite quality factor are presented in details in order to understand the physical insight and to enhance interpretations of measurement results. Recent experimental data are included to illustrate the underlying principle.

  13. Prospects for Finite-Difference Time-Domain (FDTD) Computational Electrodynamics

    NASA Astrophysics Data System (ADS)

    Taflove, Allen

    2002-08-01

    FDTD is the most powerful numerical solution of Maxwell's equations for structures having internal details. Relative to moment-method and finite-element techniques, FDTD can accurately model such problems with 100-times more field unknowns and with nonlinear and/or time-variable parameters. Hundreds of FDTD theory and applications papers are published each year. Currently, there are at least 18 commercial FDTD software packages for solving problems in: defense (especially vulnerability to electromagnetic pulse and high-power microwaves); design of antennas and microwave devices/circuits; electromagnetic compatibility; bioelectromagnetics (especially assessment of cellphone-generated RF absorption in human tissues); signal integrity in computer interconnects; and design of micro-photonic devices (especially photonic bandgap waveguides, microcavities; and lasers). This paper explores emerging prospects for FDTD computational electromagnetics brought about by continuing advances in computer capabilities and FDTD algorithms. We conclude that advances already in place point toward the usage by 2015 of ultralarge-scale (up to 1E11 field unknowns) FDTD electromagnetic wave models covering the frequency range from about 0.1 Hz to 1E17 Hz. We expect that this will yield significant benefits for our society in areas as diverse as computing, telecommunications, defense, and public health and safety.

  14. Highway runoff quality models for the protection of environmentally sensitive areas

    NASA Astrophysics Data System (ADS)

    Trenouth, William R.; Gharabaghi, Bahram

    2016-11-01

    This paper presents novel highway runoff quality models using artificial neural networks (ANN) which take into account site-specific highway traffic and seasonal storm event meteorological factors to predict the event mean concentration (EMC) statistics and mean daily unit area load (MDUAL) statistics of common highway pollutants for the design of roadside ditch treatment systems (RDTS) to protect sensitive receiving environs. A dataset of 940 monitored highway runoff events from fourteen sites located in five countries (Canada, USA, Australia, New Zealand, and China) was compiled and used to develop ANN models for the prediction of highway runoff suspended solids (TSS) seasonal EMC statistical distribution parameters, as well as the MDUAL statistics for four different heavy metal species (Cu, Zn, Cr and Pb). TSS EMCs are needed to estimate the minimum required removal efficiency of the RDTS needed in order to improve highway runoff quality to meet applicable standards and MDUALs are needed to calculate the minimum required capacity of the RDTS to ensure performance longevity.

  15. Power processor for a 30cm ion thruster

    NASA Technical Reports Server (NTRS)

    Biess, J. J.; Inouye, L. Y.

    1974-01-01

    A thermal vacuum power processor for the NASA Lewis 30cm Mercury Ion Engine was designed, fabricated and tested to determine compliance with electrical specifications. The power processor breadboard used the silicon controlled rectifier (SCR) series resonant inverter as the basic power stage to process all the power to an ion engine. The power processor includes a digital interface unit to process all input commands and internal telemetry signals so that operation is compatible with a central computer system. The breadboard was tested in a thermal vacuum environment. Integration tests were performed with the ion engine and demonstrate operational compatibility and reliable operation without any component failures. Electromagnetic interference data were also recorded on the design to provide information on the interaction with total spacecraft.

  16. Shadows of rotating five-dimensional charged EMCS black holes

    NASA Astrophysics Data System (ADS)

    Amir, Muhammed; Singh, Balendra Pratap; Ghosh, Sushant G.

    2018-05-01

    Higher-dimensional theories admit astrophysical objects like supermassive black holes, which are rather different from standard ones, and their gravitational lensing features deviate from general relativity. It is well known that a black hole shadow is a dark region due to the falling geodesics of photons into the black hole and, if detected, a black hole shadow could be used to determine which theory of gravity is consistent with observations. Measurements of the shadow sizes around the black holes can help to evaluate various parameters of the black hole metric. We study the shapes of the shadow cast by the rotating five-dimensional charged Einstein-Maxwell-Chern-Simons (EMCS) black holes, which is characterized by four parameters, i.e., mass, two spins, and charge, in which the spin parameters are set equal. We integrate the null geodesic equations and derive an analytical formula for the shadow of the five-dimensional EMCS black hole, in turn, to show that size of black hole shadow is affected due to charge as well as spin. The shadow is a dark zone covered by a deformed circle, and the size of the shadow decreases with an increase in the charge q when compared with the five-dimensional Myers-Perry black hole. Interestingly, the distortion increases with charge q. The effect of these parameters on the shape and size of the naked singularity shadow of the five-dimensional EMCS black hole is also discussed.

  17. Interface Modification of Bernal- and Rhombohedral-Stacked Trilayer-Graphene/Metal Electrode on Resistive Switching of Silver Electrochemical Metallization Cells.

    PubMed

    Wang, Jer-Chyi; Chan, Ya-Ting; Chen, Wei-Fan; Wu, Ming-Chung; Lai, Chao-Sung

    2017-10-25

    Bernal- and rhombohedral-stacked trilayer graphene (B- and r-TLG) on nickel (Ni) and iridium (Ir) films acting as bottom electrodes (BEs) of silver electrochemical metallization cells (Ag-EMCs) have been investigated in this study. Prior to the fabrication of the EMC devices, Raman mapping and atomic force microscopy are applied to identify the B- and r-TLG sheets, with the latter revealing a significant D peak and a rough surface for the Ir film. The Ag-EMCs with the stacked BE of r-TLG on the Ir film show a conductive mechanism of Schottky emission at the positive top electrode bias for both high- and low-resistance states that can be examined by the resistance change with the device area and are modulated by pulse bias operation. Thus, an effective electron barrier height of 0.262 eV at the r-TLG and Ir interface is obtained because of the conspicuous energy gap of r-TLG on the Ir film and the van der Waals (vdW) gap between the r-TLG and Ir contact metal. With the use of Ni instead of Ir contact metal, the Ag-EMCs with TLG BE demonstrate +0.3 V/-0.75 V operation voltages, more than 10 4 s data retention at 115 °C and 250 times endurance testing, making the TLG sheets suitable for low-power nonvolatile memory applications on flexible substrates.

  18. Evaluation of Bluetooth as a replacement for cables in intensive care and surgery.

    PubMed

    Wallin, Mats K E B; Wajntraub, Samson

    2004-03-01

    In today's intensive care and surgery, a great number of cables are attached to patients. These cables can make the care and nursing of the patient difficult. Replacing them with wireless communications technology would facilitate patient care. Bluetooth is a modern radio technology developed specifically to replace cables between different pieces of communications equipment. In this study we sought to determine whether Bluetooth is a suitable replacement for cables in intensive care and during surgery with respect to electromagnetic compatibility. The following questions were addressed: Does Bluetooth interfere with medical equipment? And does the medical equipment decrease the quality of the Bluetooth communication? A Bluetooth link, simulating a patient monitoring system, was constructed with two laptops. The prototype was then used in laboratory and clinical tests according to American standards at the Karolinska Hospital in Stockholm. The tests, which included 44 different pieces of medical equipment, indicated that Bluetooth does not cause any interference. The tests also showed that the hospital environment does not affect the Bluetooth communication negatively. Bluetooth, a new radio technology transmitting at 2.4 GHz, was tested in a clinical setting. The study showed that a single Bluetooth link was robust and electromagnetically compatible with the tested electronic medical devices.

  19. EMC effect: Past, Present, and Future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fomin, Nadia

    2015-09-01

    Since the discovery of the EMC effect over 30 years ago, it has been of great theoretical interest and studied in several experimental measurements. No unified picture arose to explain the underlying cause of per nucleon structure function modification in nuclei. Precise measurements on light nuclei from JLab’s 6 GeV era revitalized this research by showing that traditional A or density dependent models of this nuclear modification do not work. The measurements will be reviewed, discussed and preliminary data on heavy targets from JLab’s E03-103 will be presented.

  20. On the deduction of chemical reaction pathways from measurements of time series of concentrations.

    PubMed

    Samoilov, Michael; Arkin, Adam; Ross, John

    2001-03-01

    We discuss the deduction of reaction pathways in complex chemical systems from measurements of time series of chemical concentrations of reacting species. First we review a technique called correlation metric construction (CMC) and show the construction of a reaction pathway from measurements on a part of glycolysis. Then we present two new improved methods for the analysis of time series of concentrations, entropy metric construction (EMC), and entropy reduction method (ERM), and illustrate (EMC) with calculations on a model reaction system. (c) 2001 American Institute of Physics.

  1. Open-field test site

    NASA Astrophysics Data System (ADS)

    Gyoda, Koichi; Shinozuka, Takashi

    1995-06-01

    An open-field test site with measurement equipment, a turn table, antenna positioners, and measurement auxiliary equipment was remodelled at the CRL north-site. This paper introduces the configuration, specifications and characteristics of this new open-field test site. Measured 3-m and 10-m site attenuations are in good agreement with theoretical values, and this means that this site is suitable for using 3-m and 10-m method EMI/EMC measurements. The site is expected to be effective for antenna measurement, antenna calibration, and studies on EMI/EMC measurement methods.

  2. Assessment of Stirling Technology Has Provided Critical Data Leading Toward Flight Readiness of the Stirling Converter

    NASA Technical Reports Server (NTRS)

    Thieme, Lanny G.

    2001-01-01

    The NASA Glenn Research Center is supporting the development of a Stirling converter with the Department of Energy (DOE, Germantown, Maryland) for an advanced Stirling Radioisotope Power System (SRPS) to provide spacecraft onboard electric power for NASA space science missions. A key technology assessment completed by Glenn and DOE has led to the SRPS being identified as a high-efficiency power source for such deep space missions as the Europa Orbiter and the Solar Probe. In addition, the Stirling system is now being considered for unmanned Mars rovers, especially where mission profiles may exclude the use of photovoltaic power systems, such as exploration at high Martian latitudes or for missions of long duration. The SRPS efficiency of over 20 percent will reduce the required amount of radioisotope by more than a factor of 3 in comparison to current radioisotope thermoelectric generators. This significantly reduces radioisotope cost, radiological inventory, and system cost, and it provides efficient use of scarce radioisotope resources. In support of this technology assessment, Glenn conducted a series of independent evaluations and tests to determine the technology readiness of a 55-We Stirling converter developed by Stirling Technology Company (Kennewick, Washington) and DOE. Key areas evaluated by Glenn included: 1) Radiation tolerance of materials; 2) Random vibration testing of the Stirling converter in Glenn's Structural Dynamics Lab to simulate operation in the launch environment; 3) Electromagnetic interference and compatibility (EMI/EMC) of the converter operating in Glenn's EMI lab; Independent failure modes, effects, and criticality analysis, and life and reliability 4. Independent failure modes, effects, and criticality analysis, and life and reliability assessment; and 5) SRPS cost estimate. The data from these evaluations were presented to NASA Headquarters and the Jet Propulsion Laboratory mission office by a joint industry/Government team consisting of DOE, Glenn, and Lockheed Martin Astronautics. This team concluded that there are no technical reasons that would rule out using the Stirling converter for deep space missions. As a direct result of the successful testing at Glenn, the DOE/Stirling Technology Company 55-We Stirling converter has been baselined for the SRPS. Glenn is now continuing an in-house project to assist in developing the Stirling converter for readiness for space qualification and mission implementation. As part of this effort, the Stirling converter will be further characterized under launch environment random vibration testing, methods to reduce converter EMI will be developed, and an independent performance verification will be completed. Converter life assessment and permanent magnet aging characterization tasks are also underway. Substitute organic materials for the linear alternator and piston bearing coatings for use in a high-radiation environment have been identified and have now been incorporated in Stirling converters built by Stirling Technology Company for Glenn. Electromagnetic and thermal finite element analyses for the alternator are also being conducted.

  3. Unusual characteristics of electromagnetic waves excited by cometary newborn ions with large perpendicular energies

    NASA Technical Reports Server (NTRS)

    Brinca, A. L.; Tsurutani, B. T.

    1987-01-01

    The characteristics of electromagnetic waves excited by cometary newborn ions with large perpendicular energies are examined using a model of solar wind permeated by dilute drifting ring distributions of electrons and oxygen ions with finite thermal spreads. The model has parameters compatible with the ICE observations at the Giacobini-Zinner comet. It is shown that cometary newborn ions with large perpendicular energies can excite a wave mode with rest frame frequencies in the order of the heavy ion cyclotron frequency, Omega(i), and unusual propagation characteristics at small obliquity angles. For parallel propagation, the mode is left-hand circularly polarized, might be unstable in a frequency range containing Omega(i), and moves in the direction of the newborn ion drift along the static magnetic field.

  4. Different styles of postseismic deformation after the 2013 M7.7 Balochistan earthquake in Pakistan and the 2010 M7.2 El Mayor-Cucapah earthquake in Mexico

    NASA Astrophysics Data System (ADS)

    Fielding, E. J.; Yague-Martinez, N.; Motagh, M.; Gonzalez-Ortega, J. A.; Huang, M. H.; Burgmann, R.; Freed, A. M.; Samsonov, S. V.

    2014-12-01

    We study postseismic deformation after the Mw 7.7 earthquake in the Balochistan region of western Pakistan on 24 September 2013 and the Mw 7.2 El Mayor-Cucapah (EMC) earthquake in Baja California of northern Mexico on 4 April 2010. Pakistan InSAR measurements from the German TerraSAR-X (TSX) and Canadian RADARSAT-2 (RS2) satellites include TSX narrow stripmap beams on a descending track, RS2 wide strip modes, and TSX wide-swath ScanSAR images on an ascending track, specially acquired with interferometric alignment of ScanSAR bursts. For the EMC earthquake, InSAR includes Envisat, ALOS, and RS2 satellites and NASA/JPL UAVSAR airborne InSAR, with piece-wise time coverage. Plate Boundary Observatory acquires continuous GPS data and others collect campaign GPS. Interferograms show significant afterslip on both main ruptures in the first weeks and months, not masked by the atmospheric effects. Balochistan shallow afterslip reaches at least 10 cm in 2-4 months in the same area as the largest coseismic slip, but less near the aftershock activity. Rapid afterslip was observed primarily at the ends of the EMC mainshock rupture where the strike changes, with magnitudes up to 30 cm. Large variations of tropospheric water vapor complicate measurement of small long-wavelength deformation so we do time series analysis. We expect viscoelastic relaxation after these two strike-slip earthquakes to differ due to completely opposite tectonic settings: EMC earthquake in the Salton Trough rift and fast-moving strike-slip system, where crust and lithosphere are thin and hot with very shallow asthenosphere, and Balochistan earthquake in the shortening Makran accretional prism with much slower strike-slip deformation rates and cold and thick lithosphere of the subducting Arabian plate directly beneath it, so asthenosphere is much deeper. Studies have found rapid and large viscoelastic relaxation for the EMC quake, but we don't expect measurable relaxation in the Balochistan area in the first year, based on preliminary modeling. These very different lithospheric configurations have strong implications for transfer of stress and future earthquake risk.

  5. Development of Biocompatibility Procedures for Assessment of Plant Growth in Ground Test Hardware for the EMCS

    NASA Technical Reports Server (NTRS)

    Bowman, R. N.; Steele, M. K.; Sun, S. (Technical Monitor)

    2002-01-01

    The European Modular Cultivation System (EMCS) is an European Space Agency-developed facility designed to support plant research in microgravity on the IS NASA is responsible for providing US specific hardware to use within the EMCS. In preparation for flight, research will be developed and tested at Ames Research Center in the EMCS ground test hardware, the Experiment Reference Module (ERM) In order to determine the acceptability of the ERM for such purposes, biocompatibility tests will be performed to determine that the hardware functions as intended and successfully supports the' growth of plants. In this report, we describe the development of procedures and the collection of baseline data against which to compare ERM function, e.g. biocompatibility testing. A simple and robust system was developed to grow whole Arabidopsis thaliana plants within the confined volumes characteristic of spaceflight hardware. Our system for growing plants eliminated the necessity of a water/nutrient delivery system and allowed for quantifiable assessment of individual plants, as well as entire population dynamics. To insure uniform germination, seeds were started in small straw segments and transplanted into modified scintillation vials. Seedlings were selected prior to transplantation to decrease genetic variability. Plants were grown for a total of 24 days in standard laboratory plant growth chambers under controlled conditions. Sequential digital still images were taken on a daily basis. Analysis of these images allowed for the quantification of even minute environmental effect, on growth dynamics whole plants. The data collected provide reliable growth curves against which to compare plants grown in the ERM.

  6. Use of phosphoranimines to reduce organic carbonate content in Li-ion battery electrolytes

    DOE PAGES

    Dufek, Eric J.; Klaehn, John R.; McNally, Joshua S.; ...

    2016-05-09

    In this study, the use of phosphoranimines (PAs), a class of linear, monomeric phosphazenes, as electrolytes for Li-ion battery applications has been investigated as a route to improve safety and stability for Li-ion batteries. Of the potential PAs for use in battery applications, this work focuses on the initial synthetic preparation and analysis of N-trimethylsilyl-P,P-bis((2-methoxyethoxy)ethoxy)-P-ethylphosphoranimine (PA-5). PA-5 has high LiPF6 solubility in excess of 2 M, high thermal stability with a melting point below -80°C and high thermal stability as a neat compound to at least 250°C. As part of electrolyte blends, the inclusion of PA-5 shifts the onset ofmore » thermal degradation by close to 40°C at 35% loading and by 20°C at a 10% loading, improves the low temperature performance of the electrolyte, and when used as a primary solvent leads to increases in the flash point (by 20°C) when compared to more traditional EC:EMC blends. Cycling capabilities of full-coin cells with graphite negative electrodes and Li 1+w[Ni 0.5Mn 0.3Co 0.2] 1-wO 2 positive electrodes using PA-5:EC:EMC electrolyte blends are comparable with the performance seen for traditional EC:EMC blends. Analysis of the impact of the use of additives such as vinylene carbonate in PA-5:EC:EMC blended electrolyte results in enhanced capacity retention and improved coulombic efficiency.« less

  7. Impact of Non-Uniformity in Light Collection on the Energy Resolution of the PANDA Electromagnetic Calorimeter at Photon Energies Below 1 GeV

    NASA Astrophysics Data System (ADS)

    Diehl, Stefan; Brinkmann, Kai-Thomas; Drexler, Peter; Dormenev, Valery; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg; PANDA-Collaboration

    2017-11-01

    The electromagnetic calorimeter (EMC) of the PANDA detector at the future FAIR facility comprises more than 15,000 lead tungstate (PWO) crystals. The barrel part will consist of 11 crystal geometries with different degree of tapering, which causes a non-uniformity in light collection as an interplay between the focusing and the internal absorption of the light. For the most tapered crystals the detected light is enhanced by 40%, if the scintillation process is created in the front part of the crystal. Due to the shower development and its fluctuations the non-uniformity leads to a reduction of the energy resolution. To reduce this effect, one lateral crystal side face has been de-polished to a roughness of 0.3 μm. Measurements confirm an increase of the light yield in the rear part of the crystal. In contrast, only a slight decrease can be observed in the front part. The overall non-uniformity is significantly reduced below 5%. This paper will discuss the experimental studies based on GEANT4 and optical simulations to understand the impact of a de-polished side face on the light collection. For consequences on the future performance, a 3×3 sub-array of de-polished crystals was directly studied using a tagged photon beam in the energy range from 50 MeV up to 800 MeV, respectively, performed at the tagged photon facility at MAMI, Mainz. The comparison to an array composed of polished crystals confirms a significant improvement of the constant term of the energy resolution from above 2 % down to 0.5 % and only a small increase of the statistical term. The results can be reproduced in GEANT4 simulations.

  8. Estimation of the interference coupling into cables within electrically large multiroom structures

    NASA Astrophysics Data System (ADS)

    Keghie, J.; Kanyou Nana, R.; Schetelig, B.; Potthast, S.; Dickmann, S.

    2010-10-01

    Communication cables are used to transfer data between components of a system. As a part of the EMC analysis of complex systems, it is necessary to determine which level of interference can be expected at the input of connected devices due to the coupling into the irradiated cable. For electrically large systems consisting of several rooms with cables connecting components located in different rooms, an estimation of the coupled disturbances inside cables using commercial field computation software is often not feasible without several restrictions. In many cases, this is related to the non-availability of computing memory and processing power needed for the computation. In this paper, we are going to show that, starting from a topological analysis of the entire system, weak coupling paths within the system can be can be identified. By neglecting these coupling paths and using the transmission line approach, the original system will be simplified so that a simpler estimation is possible. Using the example of a system which is composed of two rooms, multiple apertures, and a network cable located in both chambers, it is shown that an estimation of the coupled disturbances due to external electromagnetic sources is feasible with this approach. Starting from an incident electromagnetic field, we determine transfer functions describing the coupling means (apertures, cables). Using these transfer functions and the knowledge of the weak coupling paths above, a decision is taken regarding the means for paths that can be neglected during the estimation. The estimation of the coupling into the cable is then made while taking only paths with strong coupling into account. The remaining part of the wiring harness in areas with weak coupling is represented by its input impedance. A comparison with the original network shows a good agreement.

  9. High speed data transmission coaxial-cable in the space communication system

    NASA Astrophysics Data System (ADS)

    Su, Haohang; Huang, Jing

    2018-01-01

    An effective method is proved based on the scattering parameter of high speed 8-core coaxial-cable measured by vector network analyzer, and the semi-physical simulation is made to receive the eye diagram at different data transmission rate. The result can be apply to analysis decay and distortion of the signal through the coaxial-cable at high frequency, and can extensively design for electromagnetic compatibility of high-speed data transmission system.

  10. High-voltage compatible, full-depleted CCD

    DOEpatents

    Holland, Stephen Edward

    2007-09-18

    A charge coupled device for detecting electromagnetic and particle radiation is described. The device includes a high-resistivity semiconductor substrate, buried channel regions, gate electrode circuitry, and amplifier circuitry. For good spatial resolution and high performance, especially when operated at high voltages with full or nearly full depletion of the substrate, the device can also include a guard ring positioned near channel regions, a biased channel stop, and a biased polysilicon electrode over the channel stop.

  11. Engineering Design Handbook. Electromagnetic Compatibility

    DTIC Science & Technology

    1977-03-01

    sliding action between turns. For more effective shielding, it may be covered with one or more layers of woven metal braid . The hose must be used in...shield. Details on this structure are given in Military Standards MS 51010 and 51011. In addition, flexible metal hoses of both braided and solid...signal cables. Flexible conduits for high- and low-voltage shield- ing usually consist of flexible metal hoses over which are wound one or more

  12. Northeast Artificial Intelligence Consortium (NAIC). Volume 12. Computer Architecture for Very Large Knowledge Bases

    DTIC Science & Technology

    1990-12-01

    data rate to the electronics would be much lower on the average and the data much "richer" in information. Intelligent use of...system bottleneck, a high data rate should be provided by I/O systems. 2. machines with intelligent storage management specially designed for logic...management information processing, surveillance sensors, intelligence data collection and handling, solid state sciences, electromagnetics, and propagation, and electronic reliability/maintainability and compatibility.

  13. Spectrum Management and Electromagnetic Compatibility Issues in the Department of Defense

    DTIC Science & Technology

    1991-01-01

    Interference JEWC Joint Electronic Warfare Center JRFL Joint Restricted Frequency List JSMS Joint Spectrum Management System JT&E Joint Test and Evaluation JTAC...Joint Restricted Frequency List (JRFL) is essentially a list of frequencies prohibited from use by ECM units. Creation and maintenance of the JRFL to...sponsored by CECOM, developed a prototype that primarily acted as an analysis of the restricted frequency list as a predecessor to DECON. Presently the Army

  14. EMC problems on board the remote sensing and communications satellites equipped with electric propulsions

    NASA Astrophysics Data System (ADS)

    Plokhikh, A.; Vazhenin, N.; Soganova, G.

    Wide application of electric propulsions (EP) as attitude control and orbit correction thrusters for a numerous class of satellites (remote sensing and communications satellites including) imposes new problems before the developers in meeting the electromagnetic compatibility requirements on board these satellites. This is connected with the fact that any EP is a source of interference broad-band emission reaching, as a rule, frequency ranges used by on-board radio systems designed for remote sensing and communications. In this case, reliable joint operation should be secured for the highly sensitive on -board radio receiving systems and sensors of remote sensing systems on one hand and EP on the other. In view of this, analysis is rather actual for the influence of EP interference emission upon the parameters and characteristics of modern remote sensing and communications systems. Procedures and results of typical operating characteristics calculation for the radio systems with the presence of operating EP on board are discussed in the paper on the basis of systematic approach with the following characteristics being among them: signal-to-noise ratio, range, data transmission rate, error probability, etc. EP effect is taken into account by the statistical analysis for the results of joint influence of valid signal and interference produced by EP upon the quality indices of communication systems and paths of the sensors being the parts of remote sensing systems. Test data for the measured EP interference characteristics were used for qualitative assessments. All necessary measurements were made by authors on the basis of the test procedure developed by them for assessing self- em ission of EP under ground conditions that may be used as a base for the certification of such measurements. Analysis was made on the basis of test data obtained and calculation procedures developed by authors for the EP influence upon the qualitative characteristics of remote sensing and communications radio systems that revealed the presence of destructive effect resulting in substantial decrease in maximum range and data transmission rate, as well as reduction of sensitivity for the sensors of remote sensing systems. Recommendations are given on the basis of analysis made for the optimization of radio systems and calibration of their sensors at a presence of electric propulsions on board the satellites.

  15. The Effects of Simulated Weightlessness on Susceptibility to Viral and Bacterial Infections Using a Murine Model

    NASA Technical Reports Server (NTRS)

    Gould, C. L.

    1985-01-01

    Certain immunological responses may be compromised as a result of changes in environmental conditions, such as the physiological adaptation to and from the weightlessness which occurs during space flight and recovery. A murine antiorthostatic model was developed to simulate weightlessness. Using this model, the proposed study will determine if differences in susceptibility to viral and bacterial infections exist among mice suspended in an antiorthostatic orientation to simulate weightlessness, mice suspended in an orthostatic orientation to provide a stressful situation without the condition of weightlessness simulation, and non-suspended control mice. Inbred mouse strains which are resistant to the diabetogenic effects of the D variant of encephalomyocarditis virus (EMC-D) and the lethal effects of Salmonella typhimurium will be evaluated. Glucose tolerance tests will be performed on all EMC-D-infected and non-infected control groups. The incidence of EMC-D-induced diabetes and the percentage survival of S. typhimurium-infected animals will be determined in each group. An additional study will determine the effects of simulated weightlessness on murine responses to exogenous interferon.

  16. EMC effect for light nuclei: New results from Jefferson Lab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aji Daniel

    High energy lepton scattering has been the primary tool for mapping out the quark distributions of nucleons and nuclei. Measurements of deep inelastic scattering in nuclei show that the quark distributions in heavy nuclei are not simply the sum of the quark distributions of the constituent proton and neutron, as one might expect for a weakly bound system. This modification of the quark distributions in nuclei is known as the EMC effect. I will discuss the results from Jefferson Lab (JLab) experiment E03-103, a precise measurement of the EMC effect in few-body nuclei with emphasis on the large x region.more » Data from the light nuclei suggests that the nuclear dependence of the high x quark distribution may depend on the nucleon's local environment, rather than being a purely bulk effect. In addition, I will also discuss about a future experiment at the upgraded 12 GeV Jefferson Lab facility which will further investigate the role of the local nuclear environment and the influence of detailed nuclear structure to the modification of quark distributions.« less

  17. Transport simulations of linear plasma generators with the B2.5-Eirene and EMC3-Eirene codes

    DOE PAGES

    Rapp, Juergen; Owen, Larry W.; Bonnin, X.; ...

    2014-12-20

    Linear plasma generators are cost effective facilities to simulate divertor plasma conditions of present and future fusion reactors. For this research, the codes B2.5-Eirene and EMC3-Eirene were extensively used for design studies of the planned Material Plasma Exposure eXperiment (MPEX). Effects on the target plasma of the gas fueling and pumping locations, heating power, device length, magnetic configuration and transport model were studied with B2.5-Eirene. Effects of tilted or vertical targets were calculated with EMC3-Eirene and showed that spreading the incident flux over a larger area leads to lower density, higher temperature and off-axis profile peaking in front of themore » target. In conclusion, the simulations indicate that with sufficient heating power MPEX can reach target plasma conditions that are similar to those expected in the ITER divertor. B2.5-Eirene simulations of the MAGPIE experiment have been carried out in order to establish an additional benchmark with experimental data from a linear device with helicon wave heating.« less

  18. Muscle contraction and the elasticity-mediated crosstalk effect

    NASA Astrophysics Data System (ADS)

    Dharan, Nadiv; Farago, Oded

    2013-05-01

    Cooperative action of molecular motors is essential for many cellular processes. One possible regulator of motor coordination is the elasticity-mediated crosstalk (EMC) coupling between myosin II motors whose origin is the tensile stress that they collectively generate in actin filaments. Here, we use a statistical mechanical analysis to investigate the influence of the EMC effect on the sarcomere — the basic contractile unit of skeletal muscles. We demonstrate that the EMC effect leads to an increase in the attachment probability of motors located near the end of the sarcomere while simultaneously decreasing the attachment probability of the motors in the central part. Such a polarized attachment probability would impair the motors' ability to cooperate efficiently. Interestingly, this undesired phenomenon becomes significant only when the system size exceeds that of the sarcomere in skeletal muscles, which provides an explanation for the remarkable lack of sarcomere variability in vertebrates. Another phenomenon that we investigate is the recently observed increase in the duty ratio of the motors with the tension in muscle. We reveal that the celebrated Hill's equation for muscle contraction is very closely related to this observation.

  19. Liquid-Metal-Fed Pulsed Electromagnetic Thrusters For In-Space Propulsion

    NASA Technical Reports Server (NTRS)

    Markusic, T. E.

    2004-01-01

    We describe three pulsed electromagnetic thruster concepts, which span four orders of magnitude in power processing capability (100 W to >100 kW), for in-space propulsion applications. The primary motivation for using a pulsed system is to is to enable high (instantaneous) power operation, which provides high acceleration efficiency, while using considerably less (continuous) power from the spacecraft power system. Unfortunately, conventional pulsed thrusters require failure-prone electrical switches and gas-puff valves. The series of thrusters described here directly address this problem, through the use of liquid metal propellant, by either eliminating both components or providing less taxing operational requirements, thus yielding a path toward both efficient and reliable pulsed electromagnetic thrusters. The emphasis of this paper is to conceptually describe each of the thruster concepts; however, initial test results with gallium propellant in one thruster geometry are presented. These tests reveal that a greater understanding of gallium material compatibility, contamination, and wetting behavior will be necessary before a completely functional thruster can be developed. Initial experimental results aimed at providing insight into these issues are presented.

  20. Electromagnetic potentials basis for energy density and power flux

    NASA Astrophysics Data System (ADS)

    Puthoff, H. E.

    2016-09-01

    In rounding out the education of students in advanced courses in applied electromagnetics it is incumbent on us as mentors to raise issues that encourage appreciation of certain subtle aspects that are often overlooked during first exposure to the field. One of these has to do with the interplay between fields and potentials, with the latter often seen as just a convenient mathematical artifice useful in solving Maxwell’s equations. Nonetheless, to those practiced in application it is well understood that various alternatives in the use of fields and potentials are available within electromagnetic (EM) theory for the definitions of energy density, momentum transfer, EM stress-energy tensor, and so forth. Although the various options are all compatible with the basic equations of electrodynamics (e.g., Maxwell’s equations, Lorentz force law, gauge invariance), nonetheless certain alternative formulations lend themselves to being seen as preferable to others with regard to the transparency of their application to physical problems of interest. Here we argue for the transparency of an energy density/power flux option based on the EM potentials alone.

  1. First Search for the EMC Effect and Nuclear Shadowing in Neutrino Nucleus Deep Inelastic Scattering at MINERvA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mousseau, Joel A.

    2015-01-01

    Decades of research in electron-nucleus deep inelastic scattering (DIS) have provided a clear picture of nuclear physics at high momentum transfer. While these effects have been clearly demonstrated by experiment, the theoretical explanation of their origin in some kinematic regions has been lacking. Particularly, the effects in the intermediate regions of Bjorken-x, anti-shadowing and the EMC effect have no universally accepted quantum mechanical explanation. In addition, these effects have not been measured systematically with neutrino-nucleus deep inelastic scattering, due to experiments lacking multiple heavy targets.

  2. Motionless phase stepping in X-ray phase contrast imaging with a compact source

    PubMed Central

    Miao, Houxun; Chen, Lei; Bennett, Eric E.; Adamo, Nick M.; Gomella, Andrew A.; DeLuca, Alexa M.; Patel, Ajay; Morgan, Nicole Y.; Wen, Han

    2013-01-01

    X-ray phase contrast imaging offers a way to visualize the internal structures of an object without the need to deposit significant radiation, and thereby alleviate the main concern in X-ray diagnostic imaging procedures today. Grating-based differential phase contrast imaging techniques are compatible with compact X-ray sources, which is a key requirement for the majority of clinical X-ray modalities. However, these methods are substantially limited by the need for mechanical phase stepping. We describe an electromagnetic phase-stepping method that eliminates mechanical motion, thus removing the constraints in speed, accuracy, and flexibility. The method is broadly applicable to both projection and tomography imaging modes. The transition from mechanical to electromagnetic scanning should greatly facilitate the translation of X-ray phase contrast techniques into mainstream applications. PMID:24218599

  3. Air Force Space Command. Space and Missile Systems Center Standard. Electromagnetic Compatibility Requirements for Space Equipment and Systems

    DTIC Science & Technology

    2008-06-13

    technology developments. 2. This new-issue SMC standard comprises the text of The Aerospace Corporation report number TOR-2005( 8583 )-1. 3...issues of the documents are the current versions. 1. Aerospace Report No. TOR-2005( 8583 )-2, Electrical Power Systems, Direct Current, Space Vehicle...Design Requirements, The Aerospace Corp., 13 January 2005. 2. Aerospace Report No. TR-2004( 8583 )-1 (proposed MIL-STD-1540E), Test Requirements for

  4. Determining Tactical Usage Of Non-Lethal Weapons For Fixed Site Security Of U.S. Embassies

    DTIC Science & Technology

    2017-06-01

    Nigeria, including a bombing of the UN headquarters building in Abuja in 2011 (Mshelizza, 2011). Figure 2 shows a map of Nigeria, and Figure 3 shows a...radiofrequency countermeasures; electro-magnetic ( EM ) compatibility and deception; EM hardening, interference, intrusion, and jamming; electronic masking...Boko Haram claim U.N. bombing . Reuters. Retrieved from http://www.reuters.com/article/us-nigeria- bombing -claim- idUSTRE77S3ZO20110829 Nance, R. E

  5. Microstructural Characterization of Polymers with Positrons

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.

    1997-01-01

    Positrons provide a versatile probe for monitoring microstructural features of molecular solids. In this paper, we report on positron lifetime measurements in two different types of polymers. The first group comprises polyacrylates processed on earth and in space. The second group includes fully-compatible and totally-incompatible Semi-Interpenetrating polymer networks of thermosetting and thermoplastic polyimides. On the basis of lifetime measurements, it is concluded that free volumes are a direct reflection of physical/electromagnetic properties of the host polymers.

  6. Advanced Computational Methods for Study of Electromagnetic Compatibility

    DTIC Science & Technology

    2011-03-31

    following result establishes the super-algebraic convergence of Gper ,Lk to Gperk : Theorem 2.1 (Bruno, Shipman, Turc, Venakides) If k is not a Wood...Gperk (x,x ′)− Gper ,Lk (x,x ′)| ≤ CL 1 2 −p. Figure 7 demonstrates the excellent accuracies arising from use of Theorem 2.1. Separable variables...representations of non-adjacent interactions. In order to further accelerate the evaluation of Gper ,Lk , we derive Taylor series expansions of quantities Gk

  7. Department of the Air Force Supporting Data for Fiscal Year 1992/1993 Budget Estimates Submitted to Congress February 1991: Descriptive Summaries, Research, Development, Test and Evaluation

    DTIC Science & Technology

    1991-02-01

    of selected heat shield materials in a plasma arc. - (U) Identify technology requirements for rapid characterization of the geophysical parameters of...NY; Analytical Systems Engineering Corporation, Burlington, MA; Earth Technology Corporation, Seattle, WA; and the Electromagnetic Compatibility...and 1800 nautical miles . The radar system will provide surveillance coverage of the east and west approaches to North America. C. (U) JUSTIFICATION

  8. Modern wireless telecommunication technologies and their electromagnetic compatibility with life-supporting equipment.

    PubMed

    Wallin, Mats K E B; Marve, Therese; Hakansson, Peter K

    2005-11-01

    Hospitals rely on pagers and ordinary telephones to reach staff members in emergency situations. New telecommunication technologies such as General Packet Radio Service (GPRS), the third generation mobile phone system Universal Mobile Telecommunications System (UMTS), and Wireless Local Area Network (WLAN) might be able to replace hospital pagers if they are electromagnetically compatible with medical devices. In this study, we sought to determine if GPRS, UMTS (Wideband Code Division Multiple Access-Frequency Division Duplex [WCDMA FDD]), and WLAN (IEEE 802.11b) transmitted signals interfere with life-supporting equipment in the intensive care and operating room environment. According to United States standard, ANSI C63.18-1997, laboratory tests were performed on 76 medical devices. In addition, clinical tests during 11 operations and 100 h of intensive care were performed. UMTS and WLAN signals caused little interference. Devices using these technologies can be used safely in critical care areas and during operations, but direct contact between medical devices and wireless communication devices ought to be avoided. In the case of GPRS, at a distance of 50 cm, it caused an older infusion pump to alarm and stop infusing; the pump had to be reset. Also, 10 cases of interference with device displays occurred. GPRS can be used safely at a distance of 1 m. Terminals/cellular phones using these technologies should be allowed without restriction in public areas because the risk of interference is minimal.

  9. Electromagnetic Design and Performance of a Conical Microwave Blackbody Target for Radiometer Calibration

    NASA Astrophysics Data System (ADS)

    Houtz, Derek A.; Emery, William; Gu, Dazhen; Jacob, Karl; Murk, Axel; Walker, David K.; Wylde, Richard J.

    2017-08-01

    A conical cavity has been designed and fabricated for use as a broadband passive microwave calibration source, or blackbody, at the National Institute of Standards and Technology. The blackbody will be used as a national primary standard for brightness temperature and will allow for the prelaunch calibration of spaceborne radiometers and calibration of ground-based systems to provide traceability among radiometric data. The conical geometry provides performance independent of polarization, minimizing reflections, and standing waves, thus having a high microwave emissivity. The conical blackbody has advantages over typical pyramidal array geometries, including reduced temperature gradients and excellent broadband electromagnetic performance over more than a frequency decade. The blackbody is designed for use between 18 and 230 GHz, at temperatures between 80 and 350 K, and is vacuum compatible. To approximate theoretical blackbody behavior, the design maximizes emissivity and thus minimizes reflectivity. A newly developed microwave absorber is demonstrated that uses cryogenically compatible, thermally conductive two-part epoxy with magnetic carbonyl iron (CBI) powder loading. We measured the complex permittivity and permeability properties for different CBI-loading percentages; the conical absorber is then designed and optimized with geometric optics and finite-element modeling, and finally, the reflectivity of the resulting fabricated structure is measured. We demonstrated normal incidence reflectivity considerably below -40 dB at all relevant remote sensing frequencies.

  10. The Electronic Medication Complete Communication (EMC2) Study: Rationale and Methods for a Randomized Controlled Trial of a Strategy to Promote Medication Safety in Ambulatory Care

    PubMed Central

    Bailey, Stacy Cooper; Paasche-Orlow, Michael K.; Adams, William G.; Brokenshire, Samantha A.; Hickson, Ryan P.; Oramasionwu, Christine U.; Curtis, Laura M.; Kwasny, Mary J.; Wolf, Michael S.

    2016-01-01

    Background Adverse drug events (ADEs) affect millions of patients annually and place a significant burden on the healthcare system. The Food and Drug Administration (FDA) has developed patient safety information for high-risk medications that pose serious public health concerns. However, there are currently few assurances that patients receive this information or are able to identify or respond correctly to ADEs. Objective To compare the effectiveness of the Electronic Medication Complete Communication (EMC2) Strategy to promote safe medication use and reporting of ADEs in comparison to usual care. Methods The automated EMC2 Strategy consists of: 1) provider alerts to counsel patients on medication risks, 2) the delivery of patient-friendly medication information via the electronic health record, and 3) an automated telephone assessment to identify potential medication concerns or ADEs. The study will take place in two community health centers in Chicago, IL. Adult, English or Spanish-speaking patients (N=1,200) who have been prescribed a high-risk medication will be enrolled and randomized to the intervention arm or usual care based upon practice location. The primary outcomes of the study are medication knowledge, proper medication use, and reporting of ADEs; these will be measured at baseline, 4 weeks, and three months. Intervention fidelity as well as barriers and costs of implementation will be evaluated. Conclusions The EMC2 Strategy automates a patient-friendly risk communication and surveillance process to promote safe medication use while minimizing clinic burden. This trial seeks to evaluate the effectiveness and feasibility of this strategy in comparison to usual care. PMID:27777127

  11. Estimating risks for water-quality exceedances of total-copper from highway and urban runoff under predevelopment and current conditions with the Stochastic Empirical Loading and Dilution Model (SELDM)

    USGS Publications Warehouse

    Granato, Gregory E.; Jones, Susan C.; Dunn, Christopher N.; Van Weele, Brian

    2017-01-01

    The stochastic empirical loading and dilution model (SELDM) was used to demonstrate methods for estimating risks for water-quality exceedances of event-mean concentrations (EMCs) of total-copper. Monte Carlo methods were used to simulate stormflow, total-hardness, suspended-sediment, and total-copper EMCs as stochastic variables. These simulations were done for the Charles River Basin upstream of Interstate 495 in Bellingham, Massachusetts. The hydrology and water quality of this site were simulated with SELDM by using data from nearby, hydrologically similar sites. Three simulations were done to assess the potential effects of the highway on receiving-water quality with and without highway-runoff treatment by a structural best-management practice (BMP). In the low-development scenario, total copper in the receiving stream was simulated by using a sediment transport curve, sediment chemistry, and sediment-water partition coefficients. In this scenario, neither the highway runoff nor the BMP effluent caused concentration exceedances in the receiving stream that exceed the once in three-year threshold (about 0.54 percent). In the second scenario, without the highway, runoff from the large urban areas in the basin caused exceedances in the receiving stream in 2.24 percent of runoff events. In the third scenario, which included the effects of the urban runoff, neither the highway runoff nor the BMP effluent increased the percentage of exceedances in the receiving stream. Comparison of the simulated geometric mean EMCs with data collected at a downstream monitoring site indicates that these simulated values are within the 95-percent confidence interval of the geometric mean of the measured EMCs.

  12. Performance of two commercial electron beam algorithms over regions close to the lung-mediastinum interface, against Monte Carlo simulation and point dosimetry in virtual and anthropomorphic phantoms.

    PubMed

    Ojala, J; Hyödynmaa, S; Barańczyk, R; Góra, E; Waligórski, M P R

    2014-03-01

    Electron radiotherapy is applied to treat the chest wall close to the mediastinum. The performance of the GGPB and eMC algorithms implemented in the Varian Eclipse treatment planning system (TPS) was studied in this region for 9 and 16 MeV beams, against Monte Carlo (MC) simulations, point dosimetry in a water phantom and dose distributions calculated in virtual phantoms. For the 16 MeV beam, the accuracy of these algorithms was also compared over the lung-mediastinum interface region of an anthropomorphic phantom, against MC calculations and thermoluminescence dosimetry (TLD). In the phantom with a lung-equivalent slab the results were generally congruent, the eMC results for the 9 MeV beam slightly overestimating the lung dose, and the GGPB results for the 16 MeV beam underestimating the lung dose. Over the lung-mediastinum interface, for 9 and 16 MeV beams, the GGPB code underestimated the lung dose and overestimated the dose in water close to the lung, compared to the congruent eMC and MC results. In the anthropomorphic phantom, results of TLD measurements and MC and eMC calculations agreed, while the GGPB code underestimated the lung dose. Good agreement between TLD measurements and MC calculations attests to the accuracy of "full" MC simulations as a reference for benchmarking TPS codes. Application of the GGPB code in chest wall radiotherapy may result in significant underestimation of the lung dose and overestimation of dose to the mediastinum, affecting plan optimization over volumes close to the lung-mediastinum interface, such as the lung or heart. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. The electronic medication complete communication (EMC2) study: Rationale and methods for a randomized controlled trial of a strategy to promote medication safety in ambulatory care.

    PubMed

    Bailey, Stacy Cooper; Paasche-Orlow, Michael K; Adams, William G; Brokenshire, Samantha A; Hickson, Ryan P; Oramasionwu, Christine U; Curtis, Laura M; Kwasny, Mary J; Wolf, Michael S

    2016-11-01

    Adverse drug events (ADEs) affect millions of patients annually and place a significant burden on the healthcare system. The Food and Drug Administration (FDA) has developed patient safety information for high-risk medications that pose serious public health concerns. However, there are currently few assurances that patients receive this information or are able to identify or respond correctly to ADEs. To evaluate the effectiveness of the Electronic Medication Complete Communication (EMC 2 ) Strategy to promote safe medication use and reporting of ADEs in comparison to usual care. The automated EMC 2 Strategy consists of: 1) provider alerts to counsel patients on medication risks, 2) the delivery of patient-friendly medication information via the electronic health record, and 3) an automated telephone assessment to identify potential medication concerns or ADEs. The study will take place in two community health centers in Chicago, IL. Adult, English or Spanish-speaking patients (N=1200) who have been prescribed a high-risk medication will be enrolled and randomized to the intervention arm or usual care based upon practice location. The primary outcomes of the study are medication knowledge, proper medication use, and reporting of ADEs; these will be measured at baseline, 4weeks, and three months. Intervention fidelity as well as barriers and costs of implementation will be evaluated. The EMC 2 Strategy automates a patient-friendly risk communication and surveillance process to promote safe medication use while minimizing clinic burden. This trial seeks to evaluate the effectiveness and feasibility of this strategy in comparison to usual care. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. [Output characteristics of rainfall runoff phosphorus pollution from a typical small watershed in Yimeng mountainous area].

    PubMed

    Yu, Xing-xiu; Li, Zhen-wei; Liu, Qian-jin; Jing, Guang-hua

    2012-08-01

    Relationships between phosphorus pollutant concentrations and precipitation-runoff were analyzed by monitoring pollutant losses at outlets of the Menglianggu watershed in 2010. A typical small watershed was selected to examine the runoff and quality parameters such as total phosphorus (TP), particle phosphorus (PP), dissolve phosphorus (DP) and dissolve inorganic phosphorus (DIP) in rainfall-runoff of 10 rainfall events. Precipitation was above 2 mm for all the 10 rainfall events. The results showed that the peak of phosphorus concentrations occurred before the peak of water flows, whereas change processes of the phosphorus fluxes were consistent with that of the water flows and the phosphorus flux also have a strong linear relationship with the water flows. The minimums of the phosphorus concentrations in every 10 natural rainfall events have small differences with each other, but the maximum and EMCs of the phosphorus concentrations have significant differences with each rainfall event. This was mainly influenced by the precipitation, maximum rainfall intensity and mean rainfall intensity (EMCs) and was less influenced by rainfall duration. DP and TP were mainly composed of DIP and PP, respectively. There were no significant correlations between DIP/DP dynamic changes and rainfall characteristics, whereas significant correlations between PP/TP dynamic changes and maximum rainfall intensity were detected. The production of DIP, DP, AND TP were mainly influenced by the direct runoff (DR) and base flow (BF). The EMCs of DIP, DP, TP and the variations of DIP/DP were all found to have significant polynomial relationships with DR/TR., but the dynamic changes of PP/ TP and the EMCS of PP were less influenced by the DR/TR.

  15. Personalized objects can optimize the diagnosis of EMCS in the assessment of functional object use in the CRS-R: a double blind, randomized clinical trial.

    PubMed

    Sun, Yuxiao; Wang, Jianan; Heine, Lizette; Huang, Wangshan; Wang, Jing; Hu, Nantu; Hu, Xiaohua; Fang, Xiaohui; Huang, Supeng; Laureys, Steven; Di, Haibo

    2018-04-12

    Behavioral assessment has been acted as the gold standard for the diagnosis of disorders of consciousness (DOC) patients. The item "Functional Object Use" in the motor function sub-scale in the Coma Recovery Scale-Revised (CRS-R) is a key item in differentiating between minimally conscious state (MCS) and emergence from MCS (EMCS). However, previous studies suggested that certain specific stimuli, especially something self-relevant can affect DOC patients' scores of behavioral assessment scale. So, we attempted to find out if personalized objects can improve the diagnosis of EMCS in the assessment of Functional Object Use by comparing the use of patients' favorite objects and other common objects in MCS patients. Twenty-one post-comatose patients diagnosed as MCS were prospectively included. The item "Functional Object Use" was assessed by using personalized objects (e.g., cigarette, paper) and non-personalized objects, which were presented in a random order. The rest assessments were performed following the standard protocol of the CRS-R. The differences between functional uses of the two types of objects were analyzed by the McNemar test. The incidence of Functional Object Use was significantly higher using personalized objects than non-personalized objects in the CRS-R. Five out of the 21 MCS studied patients, who were assessed with non-personalized objects, were re-diagnosed as EMCS with personalized objects (χ 2  = 5, df = 1, p < 0.05). Personalized objects employed here seem to be more effective to elicit patients' responses as compared to non-personalized objects during the assessment of Functional Object Use in DOC patients. Clinical Trials.gov: NCT02988206 ; Date of registration: 2016/12/12.

  16. fMRI-Compatible Electromagnetic Haptic Interface.

    PubMed

    Riener, R; Villgrattner, T; Kleiser, R; Nef, T; Kollias, S

    2005-01-01

    A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.

  17. Evaluation of the SEI using a multilayer spectroscopic ellipsometry model

    DOE PAGES

    Dufek, Eric J.

    2014-08-28

    A multilayer spectroscopic ellipsometry (SE) model has been developed to characterize SEI formation. The model, which consists of two Cauchy layers, is constructed with an inner layer meant to model primarily inorganic compounds adjacent to an electrode and an outer layer which mirrors polymeric, organic constituents on the exterior of the SEI. Comparison of 1:1 EC:EMC and 1:4 EC:EMC with 1.0 M LiPF₆ shows distinct differences in the two modeled layers. The data suggest that the thickness of both layers change over a wide potential range. These changes have been linked with other reports on the growth of the SEI.

  18. A boy asked his Mom about energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mutolo, Paul F.; Muller, David; O'Dea, James

    Representing the Energy Materials Center (EMC), this document is one of the entries in the Ten Hundred and One Word Challenge. As part of the challenge, the 46 Energy Frontier Research Centers were invited to represent their science in images, cartoons, photos, words and original paintings, but any descriptions or words could only use the 1000 most commonly used words in the English language, with the addition of one word important to each of the EFRCs and the mission of DOE energy. The mission of EMC is advancing the science of energy conversion and storage by understanding and exploiting fundamentalmore » properties of active materials and their interfaces.« less

  19. Electronically tunable phase locked loop oscillator

    NASA Astrophysics Data System (ADS)

    Balasis, M.; Davis, M. R.; Jackson, C. R.

    1982-02-01

    This report describes the design and development of a low noise, high power, variable oscillator incorporating a high 'Q' electronically tunable resonator as the frequency determining element. The VCO provides improved EMC performance in phase locked synthesizers which are a part of communications equipments. The oscillator combines a low noise VMOS transistor with the selectivity and out-of-band attenuation of a coaxial resonator to provide superior EMC performance. Several oscillator designs were examined and the basis for the final configuration is presented. Oscillator noise is discussed and models for analysis are explained. A brass board model was constructed and tested and the technical results are presented.

  20. Seasonal variation of fecal indicator bacteria in storm events within the US stormwater database.

    PubMed

    Pan, Xubin; Jones, Kim D

    2012-01-01

    Bacteria are one of the major causes of surface water impairments in the USA. Over the past several years, best management practices, including detention basins, manufactured devices, grass swales, filters and bioretention cells have been used to remove bacteria and other pollutants from stormwater runoff. However, there are data gaps in the comprehensive studies of bacteria concentrations in stormwater runoff. In this paper, the event mean concentration (EMC) of fecal indicator bacteria (Enterococcus, Escherichia coli, fecal Streptococcus group bacteria, and fecal coliform) across the USA was retrieved from the international stormwater best management practices database to analyze the seasonal variations of inflow and outflow event mean concentrations and removal efficiencies. The Kruskal-Wallis test was employed to determine the seasonal variations of bacteria indicator concentrations and removals, and the two-sample Kolmogorov-Smirnov test was used for comparing different seasonal outcomes. The results indicate that all the inflow EMC of FIB in stormwater runoff is above the water quality criteria. The seasonal differences of fecal Streptococcus group bacteria and fecal coliform are significant. Summer has the potential to increase the bacteria EMC and illustrate the seasonal differences.

  1. Implementation of the 3D edge plasma code EMC3-EIRENE on NSTX

    DOE PAGES

    Lore, J. D.; Canik, J. M.; Feng, Y.; ...

    2012-05-09

    The 3D edge transport code EMC3-EIRENE has been applied for the first time to the NSTX spherical tokamak. A new disconnected double null grid has been developed to allow the simulation of plasma where the radial separation of the inner and outer separatrix is less than characteristic widths (e.g. heat flux width) at the midplane. Modelling results are presented for both an axisymmetric case and a case where 3D magnetic field is applied in an n = 3 configuration. In the vacuum approximation, the perturbed field consists of a wide region of destroyed flux surfaces and helical lobes which aremore » a mixture of long and short connection length field lines formed by the separatrix manifolds. This structure is reflected in coupled 3D plasma fluid (EMC3) and kinetic neutral particle (EIRENE) simulations. The helical lobes extending inside of the unperturbed separatrix are filled in by hot plasma from the core. The intersection of the lobes with the divertor results in a striated flux footprint pattern on the target plates. As a result, profiles of divertor heat and particle fluxes are compared with experimental data, and possible sources of discrepancy are discussed.« less

  2. Development of an EMC3-EIRENE Synthetic Imaging Diagnostic

    NASA Astrophysics Data System (ADS)

    Meyer, William; Allen, Steve; Samuell, Cameron; Lore, Jeremy

    2017-10-01

    2D and 3D flow measurements are critical for validating numerical codes such as EMC3-EIRENE. Toroidal symmetry assumptions preclude tomographic reconstruction of 3D flows from single camera views. In addition, the resolution of the grids utilized in numerical code models can easily surpass the resolution of physical camera diagnostic geometries. For these reasons we have developed a Synthetic Imaging Diagnostic capability for forward projection comparisons of EMC3-EIRENE model solutions with the line integrated images from the Doppler Coherence Imaging diagnostic on DIII-D. The forward projection matrix is 2.8 Mpixel by 6.4 Mcells for the non-axisymmetric case we present. For flow comparisons, both simple line integral, and field aligned component matrices must be calculated. The calculation of these matrices is a massive embarrassingly parallel problem and performed with a custom dispatcher that allows processing platforms to join mid-problem as they become available, or drop out if resources are needed for higher priority tasks. The matrices are handled using standard sparse matrix techniques. Prepared by LLNL under Contract DE-AC52-07NA27344. This material is based upon work supported by the U.S. DOE, Office of Science, Office of Fusion Energy Sciences. LLNL-ABS-734800.

  3. Modulation of Intraplate Deformation in Arizona due to Far-Reaching Postseismic Relaxation Following Plate Boundary Earthquakes

    NASA Astrophysics Data System (ADS)

    Kreemer, C.; Broermann, J.; Bennett, R. A.; Blewitt, G.

    2016-12-01

    The Basin and Range of southern Arizona is mostly devoid of active faults and seismicity, although M7+ earthquakes are known to have occurred in the Quaternary. Before the 2010 Mw=7.2 El-Mayor Cucapah (EMC) earthquake, we found from GPS data 2 mm/yr of extension across this region. After the EMC, we find that the extension across southern Arizona has been reduced to near-zero; this is part of a widespread change in the region's post-EMC deformation field that can be explained by viscoelastic relaxation of the lower crust and upper mantle. If the relaxation after the EMC is so wide-spread, similar affects must have occurred after other previous large earthquakes such that the deformation field is probably ever-changing, slowly. This transient deformation field obscures any long-term deformation and makes it difficult to assess the driving forces responsible for the deformation. To model the transient deformation we consider that the observed GPS-time-series record postseismic relaxation from the most recent large earthquakes: 1992 Landers, 1999 Hector Mine, 2009 Gulf of California, 2010 EMC, and 2012 Gulf of California. The postseismic model assumes an elastic upper crust to a depth of 15 km, a Maxwell visco-elastic lower crust at 15-30 km, a Burger's body rheology for the lithospheric mantle at 30-60 km, and an asthenosphere below 60 km. A best fitting viscosity was found by a random search over the parameter space of the three viscous layers and minimizing the misfit between the corrected time series and a least squares model that includes intercept, velocity, offsets at times of earthquakes and equipment offsets and annual and semi-annual terms. The overall best fitting viscosity for the lower crust 1019.9 Pa-s, lithospheric mantle 1019.6 Pa-s, and asthenospheric mantle 1018.8 Pa-s. Both the mantle viscosities are treated as Burger rheologies with a Kelvin Voigt element 1/10 of the Maxwell element. These viscosities predict very small present-day velocity gradients associated with relaxation from pre-1992 events. We will use the corrected GPS velocity field to explore the driving sources behind the velocity field; i.e., plate motion and spatial variation in gravitational potential energy.

  4. Simulação de ejeções de massa coronal

    NASA Astrophysics Data System (ADS)

    Corsini, M. A.; Silva, A. V. R.

    2003-08-01

    Ejeções de massa coronal (EMC) são bolhas gigantes de gás permeadas por campos magnéticos que são ejetadas do Sol durante um período de várias horas. Caso estas ejeções atinjam a Terra, geralmente, causam uma série de distúrbios às comunicações de longa distância e navegação, além de danos a satélites e transformadores. Portanto, é desejável que sejamos capazes de prever quando estas ejeções atingirão a Terra. Para tanto, é necessário um bom entendimento dos mecanismos causadores das ejeções e, principalmente, de como se dá a propagação das EMC e sua interação com o vento solar que permeia o meio interplanetário. Nesse sentido foi desenvolvido um programa computacional para resolver as equações MHD (Magneto-Hidro-Dinâmica) que regem a evolução das EMC. Primeiramente foram estabelecidas as condições necessárias para descrever o vento solar, no estado estacionário, que permeia todo o meio interplanetário. Num primeiro momento, resolveu-se o sistema de equações para o caso do vento isotérmico, conhecida como a solução de Parker, a fim de testarmos o modelo. Então, foi considerado o caso do vento solar com temperatura variável no meio interplanetário. Este resultado foi utilizado como a base de nosso sistema em seu instante inicial. Posteriormente foram feitas as considerações necessárias para descrever a propagação da Ejeção de Massa Coronal. As EMC foram simuladas como um aumento de densidade e temperatura local na coroa solar. A órbita e a posição da Terra foram incluídas no sistema. Os dados gerados possibilitaram uma análise da evolução da EMC pelo meio interplanetário até encontrar-se com a Terra. Os perfis de densidade e temperatura a 1 Unidade Astronômica são comparados com os dados de satélites reportados na literatura.

  5. Microstructural Characterization of Polymers by Positron Lifetime Spectroscopy

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.

    1996-01-01

    Positrons provide a versatile probe for monitoring microstructural features of molecular solids. In this paper, we report on positron lifetime measurements in two different types of polymers. The first group comprises polyacrylates processed on earth and in space. The second group includes fully-compatible and totally-incompatible Semi-Interpenetrating polymer networks of thermosetting and thermoplastic polyimides. On the basis of lifetime measurements, it is concluded that free volumes are a direct reflection of physical/electromagnetic properties of the host polymers.

  6. Electromagnetic deformable mirror for space applications

    NASA Astrophysics Data System (ADS)

    Kuiper, S.; Doelman, N.; Overtoom, T.; Nieuwkoop, E.; Russchenberg, T.; van Riel, M.; Wildschut, J.; Baeten, M.; Spruit, H.; Brinkers, S.; Human, J.

    2017-09-01

    To increase the collecting power and to improve the angular imaging resolution, space telescopes are evolving towards larger primary mirrors. The aerial density of the telescope mirrors needs to be kept low, however, to be compatible with the launch requirements. A light-weight (primary) mirror will introduce additional optical aberrations to the system. These may be caused by for instance manufacturing errors, gravity release and thermo-elastic effects. Active Optics (AO) is a key candidate technology to correct for the resultant wave front aberrations [1].

  7. Hearing Aid–Related Standards and Test Systems

    PubMed Central

    Ravn, Gert; Preves, David

    2015-01-01

    Many documents describe standardized methods and standard equipment requirements in the field of audiology and hearing aids. These standards will ensure a uniform level and a high quality of both the methods and equipment used in audiological work. The standards create the basis for measuring performance in a reproducible manner and independent from how and when and by whom parameters have been measured. This article explains, and focuses on, relevant acoustic and electromagnetic compatibility parameters and describes several test systems available. PMID:27516709

  8. A Broadband Micro-Machined Far-Infrared Absorber

    NASA Technical Reports Server (NTRS)

    Wollack, E. J.; Datesman, A. M.; Jhabvala, C. A.; Miller, K. H.; Quijada, M. A.

    2016-01-01

    The experimental investigation of a broadband far-infrared meta-material absorber is described. The observed absorptance is greater than 0.95 from 1 to 20 terahertz (300-15 microns) over a temperature range spanning 5-300 degrees Kelvin. The meta-material, realized from an array of tapers approximately 100 microns in length, is largely insensitive to the detailed geometry of these elements and is cryogenically compatible with silicon-based micro-machined technologies. The electromagnetic response is in general agreement with a physically motivated transmission line model.

  9. Data acquisition, processing and firing aid software for multichannel EMP simulation

    NASA Astrophysics Data System (ADS)

    Eumurian, Gregoire; Arbaud, Bruno

    1986-08-01

    Electromagnetic compatibility testing yields a large quantity of data for systematic analysis. An automated data acquisition system has been developed. It is based on standard EMP instrumentation which allows a pre-established program to be followed whilst orientating the measurements according to the results obtained. The system is controlled by a computer running interactive programs (multitask windows, scrollable menus, mouse, etc.) which handle the measurement channels, files, displays and process data in addition to providing an aid to firing.

  10. Electromagnetic radiation and behavioural response of ticks: an experimental test.

    PubMed

    Vargová, Blažena; Majláth, Igor; Kurimský, Juraj; Cimbala, Roman; Kosterec, Michal; Tryjanowski, Piotr; Jankowiak, Łukasz; Raši, Tomáš; Majláthová, Viktória

    2018-05-01

    Factors associated with the increased usage of electronic devices, wireless technologies and mobile phones nowadays are present in increasing amounts in our environment. All living organisms are constantly affected by electromagnetic radiation which causes serious environmental pollution. The distribution and density of ticks in natural habitats is influenced by a complex of abiotic and biotic factors. Exposure to radio-frequency electromagnetic field (RF-EMF) constitutes a potential cause altering the presence and distribution of ticks in the environment. Our main objective was to determine the affinity of Dermacentor reticulatus ticks towards RF-EMF exposure. Originally designed and constructed radiation-shielded tube (RST) test was used to test the affinity of ticks under controlled laboratory conditions. All test were performed in an electromagnetic compatibility laboratory in an anechoic chamber. Ticks were irradiated using a Double-Ridged Waveguide Horn Antenna to RF-EMF at 900 and 5000 MHz, 0 MHz was used as control. The RF-EMF exposure to 900 MHz induced a higher concentration of ticks on irradiated arm of RST as opposed to the RF-EMF at 5000 MHz, which caused an escape of ticks to the shielded arm. This study represents the first experimental evidence of RF-EMF preference in D. reticulatus. The projection of obtained results to the natural environment could help assess the risk of tick borne diseases and could be a tool of preventive medicine.

  11. Immunity of medical electrical equipment to radiated RF disturbances

    NASA Astrophysics Data System (ADS)

    Mocha, Jan; Wójcik, Dariusz; Surma, Maciej

    2018-04-01

    Immunity of medical equipment to radiated radio frequency (RF) electromagnetic (EM) fields is a priority issue owing to the functions that the equipment is intended to perform. This is reflected in increasingly stringent normative requirements that medical electrical equipment has to conform to. A new version of the standard concerning electromagnetic compatibility of medical electrical equipment IEC 60601-1-2:2014 has recently been published. The paper discusses major changes introduced in this edition of the standard. The changes comprise more rigorous immunity requirements for medical equipment as regards radiated RF EM fields and a new requirement for testing the immunity of medical electrical equipment to disturbances coming from digital radio communication systems. Further on, the paper presents two typical designs of the input block: involving a multi-level filtering and amplification circuit and including a solution which integrates an input amplifier and an analog-to-digital converter in one circuit. Regardless of the applied solution, presence of electromagnetic disturbances in the input block leads to demodulation of the disturbance signal envelope. The article elaborates on mechanisms of amplitude detection occurring in such cases. Electromagnetic interferences penetration from the amplifier's input to the output is also described in the paper. If the aforementioned phenomena are taken into account, engineers will be able to develop a more conscious approach towards the issue of immunity to RF EM fields in the process of designing input circuits in medical electrical equipment.

  12. Project MANTIS: A MANTle Induction Simulator for coupling geodynamic and electromagnetic modeling

    NASA Astrophysics Data System (ADS)

    Weiss, C. J.

    2009-12-01

    A key component to testing geodynamic hypotheses resulting from the 3D mantle convection simulations is the ability to easily translate the predicted physiochemical state to the model space relevant for an independent geophysical observation, such as earth's seismic, geodetic or electromagnetic response. In this contribution a new parallel code for simulating low-frequency, global-scale electromagnetic induction phenomena is introduced that has the same Earth discretization as the popular CitcomS mantle convection code. Hence, projection of the CitcomS model into the model space of electrical conductivity is greatly simplified, and focuses solely on the node-to-node, physics-based relationship between these Earth parameters without the need for "upscaling", "downscaling", averaging or harmonizing with some other model basis such as spherical harmonics. Preliminary performance tests of the MANTIS code on shared and distributed memory parallel compute platforms shows favorable scaling (>70% efficiency) for up to 500 processors. As with CitcomS, an OpenDX visualization widget (VISMAN) is also provided for 3D rendering and interactive interrogation of model results. Details of the MANTIS code will be briefly discussed here, focusing on compatibility with CitcomS modeling, as will be preliminary results in which the electromagnetic response of a CitcomS model is evaluated. VISMAN rendering of electrical tomography-derived electrical conductivity model overlain by an a 1x1 deg crustal conductivity map. Grey scale represents the log_10 magnitude of conductivity [S/m]. Arrows are horiztonal components of a hypothetical magnetospheric source field used to electromagnetically excite the conductivity model.

  13. High-Density Signal Interface Electromagnetic Radiation Prediction for Electromagnetic Compatibility Evaluation.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halligan, Matthew

    Radiated power calculation approaches for practical scenarios of incomplete high- density interface characterization information and incomplete incident power information are presented. The suggested approaches build upon a method that characterizes power losses through the definition of power loss constant matrices. Potential radiated power estimates include using total power loss information, partial radiated power loss information, worst case analysis, and statistical bounding analysis. A method is also proposed to calculate radiated power when incident power information is not fully known for non-periodic signals at the interface. Incident data signals are modeled from a two-state Markov chain where bit state probabilities aremore » derived. The total spectrum for windowed signals is postulated as the superposition of spectra from individual pulses in a data sequence. Statistical bounding methods are proposed as a basis for the radiated power calculation due to the statistical calculation complexity to find a radiated power probability density function.« less

  14. Structurally Integrated Antenna Concepts for HALE UAVs

    NASA Technical Reports Server (NTRS)

    Cravey, Robin L.; Vedeler, Erik; Goins, Larry; Young, W. Robert; Lawrence, Roland W.

    2006-01-01

    This technical memorandum describes work done in support of the Multifunctional Structures and Materials Team under the Vehicle Systems Program's ITAS (Integrated Tailored Aero Structures) Project during FY 2005. The Electromagnetics and Sensors Branch (ESB) developed three ultra lightweight antenna concepts compatible with HALE UAVs (High Altitude Long Endurance Unmanned Aerial Vehicles). ESB also developed antenna elements that minimize the interaction between elements and the vehicle to minimize the impact of wing flexure on the EM (electromagnetic) performance of the integrated array. In addition, computer models were developed to perform phase correction for antenna arrays whose elements are moving relative to each other due to wing deformations expected in HALE vehicle concepts. Development of lightweight, conformal or structurally integrated antenna elements and compensating for the impact of a lightweight, flexible structure on a large antenna array are important steps in the realization of HALE UAVs for microwave applications such as passive remote sensing and communications.

  15. Time-domain system for identification of the natural resonant frequencies of aircraft relevant to electromagnetic compatibility testing

    NASA Astrophysics Data System (ADS)

    Adams, J. W.; Ondrejka, A. R.; Medley, H. W.

    1987-11-01

    A method of measuring the natural resonant frequencies of a structure is described. The measurement involves irradiating this structure, in this case a helicopter, with an impulsive electromagnetic (EM) field and receiving the echo reflected from the helicopter. Resonances are identified by using a mathematical algorithm based on Prony's method to operate on the digitized reflected signal. The measurement system consists of special TEM horns, pulse generators, a time-domain system, and Prony's algorithm. The frequency range covered is 5 megahertz to 250 megahertz. This range is determined by antenna and circuit characteristics. The measurement system is demonstrated, and measured data from several different helicopters are presented in different forms. These different forms are needed to determine which of the resonant frequencies are real and which are false. The false frequencies are byproducts of Prony's algorithm.

  16. Analysis of complex environment effect on near-field emission

    NASA Astrophysics Data System (ADS)

    Ravelo, B.; Lalléchère, S.; Bonnet, P.; Paladian, F.

    2014-10-01

    The article is dealing with uncertainty analyses of radiofrequency circuits electromagnetic compatibility emission based on the near-field/near-field (NF/NF) transform combined with stochastic approach. By using 2D data corresponding to electromagnetic (EM) field (X=E or H) scanned in the observation plane placed at the position z0 above the circuit under test (CUT), the X field map was extracted. Then, uncertainty analyses were assessed via the statistical moments from X component. In addition, stochastic collocation based was considered and calculations were applied to planar EM NF radiated by the CUTs as Wilkinson power divider and a microstrip line operating at GHz levels. After Matlab implementation, the mean and standard deviation were assessed. The present study illustrates how the variations of environmental parameters may impact EM fields. The NF uncertainty methodology can be applied to any physical parameter effects in complex environment and useful for printed circuit board (PCBs) design guideline.

  17. A methodology to enhance electromagnetic compatibility in joint military operations

    NASA Astrophysics Data System (ADS)

    Buckellew, William R.

    The development and validation of an improved methodology to identify, characterize, and prioritize potential joint EMI (electromagnetic interference) interactions and identify and develop solutions to reduce the effects of the interference are discussed. The methodology identifies potential EMI problems using results from field operations, historical data bases, and analytical modeling. Operational expertise, engineering analysis, and testing are used to characterize and prioritize the potential EMI problems. Results can be used to resolve potential EMI during the development and acquisition of new systems and to develop engineering fixes and operational workarounds for systems already employed. The analytic modeling portion of the methodology is a predictive process that uses progressive refinement of the analysis and the operational electronic environment to eliminate noninterfering equipment pairs, defer further analysis on pairs lacking operational significance, and resolve the remaining EMI problems. Tests are conducted on equipment pairs to ensure that the analytical models provide a realistic description of the predicted interference.

  18. Fiber Optic System Test Results In A Tactical Military Aircraft

    NASA Astrophysics Data System (ADS)

    Uhlhorn, Roger W.; Greenwell, Roger A.

    1980-09-01

    The YAV-8B Electromagnetic Immunity and Flight-Test Program was established to evaluate the susceptibility of wire and optical fiber signal transmission lines to electromagnetic interference when these lines are installed in a graphite/epoxy composite wing and to demonstrate the flightworthiness of fiber optics interconnects in the vertical/ short takeoff and landing aircraft environment. In response, two fiber optic systems were designed, fabricated, and flight tested by McDonnell Aircraft Co. (MCAIR), a division of the McDonnell Douglas Corporation, on the two YAV-8B V/STOL flight test aircraft. The program successfully demonstrated that fiber optics are compatible with the attack aircraft environment. As a result, the full scale development AV-8B will incorporate fiber optics in a point-to-point data link. We describe here the fiber optic systems designs, test equipment development, cabling and connection requirements, fabrication and installation experience, and flight test program results.

  19. Space Earthquake Perturbation Simulation (SEPS) an application based on Geant4 tools to model and simulate the interaction between the Earthquake and the particle trapped on the Van Allen belt

    NASA Astrophysics Data System (ADS)

    Ambroglini, Filippo; Jerome Burger, William; Battiston, Roberto; Vitale, Vincenzo; Zhang, Yu

    2014-05-01

    During last decades, few space experiments revealed anomalous bursts of charged particles, mainly electrons with energy larger than few MeV. A possible source of these bursts are the low-frequency seismo-electromagnetic emissions, which can cause the precipitation of the electrons from the lower boundary of their inner belt. Studies of these bursts reported also a short-term pre-seismic excess. Starting from simulation tools traditionally used on high energy physics we developed a dedicated application SEPS (Space Perturbation Earthquake Simulation), based on the Geant4 tool and PLANETOCOSMICS program, able to model and simulate the electromagnetic interaction between the earthquake and the particles trapped in the inner Van Allen belt. With SEPS one can study the transport of particles trapped in the Van Allen belts through the Earth's magnetic field also taking into account possible interactions with the Earth's atmosphere. SEPS provides the possibility of: testing different models of interaction between electromagnetic waves and trapped particles, defining the mechanism of interaction as also shaping the area in which this takes place,assessing the effects of perturbations in the magnetic field on the particles path, performing back-tracking analysis and also modelling the interaction with electric fields. SEPS is in advanced development stage, so that it could be already exploited to test in details the results of correlation analysis between particle bursts and earthquakes based on NOAA and SAMPEX data. The test was performed both with a full simulation analysis, (tracing from the position of the earthquake and going to see if there were paths compatible with the burst revealed) and with a back-tracking analysis (tracing from the burst detection point and checking the compatibility with the position of associated earthquake).

  20. Comparison of Metal-Backed Free-Space and Open-Ended Coaxial Probe Techniques for the Dielectric Characterization of Aeronautical Composites †

    PubMed Central

    López-Rodríguez, Patricia; Escot-Bocanegra, David; Poyatos-Martínez, David; Weinmann, Frank

    2016-01-01

    The trend in the last few decades is that current unmanned aerial vehicles are completely made of composite materials rather than metallic, such as carbon-fiber or fiberglass composites. From the electromagnetic point of view, this fact forces engineers and scientists to assess how these materials may affect their radar response or their electronics in terms of electromagnetic compatibility. In order to evaluate this, electromagnetic characterization of different composite materials has become a need. Several techniques exist to perform this characterization, all of them based on the utilization of different sensors for measuring different parameters. In this paper, an implementation of the metal-backed free-space technique, based on the employment of antenna probes, is utilized for the characterization of composite materials that belong to an actual drone. Their extracted properties are compared with those given by a commercial solution, an open-ended coaxial probe (OECP). The discrepancies found between both techniques along with a further evaluation of the methodologies, including measurements with a split-cavity resonator, conclude that the implemented free-space technique provides more reliable results for this kind of composites than the OECP technique. PMID:27347966

  1. Blackhole formula and example relativity

    NASA Astrophysics Data System (ADS)

    Shin, Philip

    Black hole formula 1) Second dimension (x,y) f(x)=y Energy E=m*c2 2) Third dimension (x,y,z) really x=y=z Black hole formula Root(c2)=c=Root(E/m) As mass go the velocity of light, mass become black hole so there are energy as multiply by mass. Example relativity When E=m*c2 1) Root(c2)=c=Root(E/m) 2) 3*c*Root(c2)=3*c*Root(E/m)=3*c2 From 1) to 2) as an example, As velocity is faster, mass increased. It means when velocity is increased, sec(time) is slower, and m(distance) is increased. The number is good to study physics.

  2. Radio-frequency energy quantification in magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Alon, Leeor

    Mapping of radio frequency (RF) energy deposition has been challenging for 50+ years, especially, when scanning patients in the magnetic resonance imaging (MRI) environment. As result, electromagnetic simulation software is often used for estimating the specific absorption rate (SAR), the rate of RF energy deposition in tissue. The thesis work presents challenges associated with aligning information provided by electromagnetic simulation and MRI experiments. As result of the limitations of simulations, experimental methods for the quantification of SAR were established. A system for quantification of the total RF energy deposition was developed for parallel transmit MRI (a system that uses multiple antennas to excite and image the body). The system is capable of monitoring and predicting channel-by-channel RF energy deposition, whole body SAR and capable of tracking potential hardware failures that occur in the transmit chain and may cause the deposition of excessive energy into patients. Similarly, we demonstrated that local RF power deposition can be mapped and predicted for parallel transmit systems based on a series of MRI temperature mapping acquisitions. Resulting from the work, we developed tools for optimal reconstruction temperature maps from MRI acquisitions. The tools developed for temperature mapping paved the way for utilizing MRI as a diagnostic tool for evaluation of RF/microwave emitting device safety. Quantification of the RF energy was demonstrated for both MRI compatible and non-MRI-compatible devices (such as cell phones), while having the advantage of being noninvasive, of providing millimeter resolution and high accuracy.

  3. A proto-type design of a real-tissue phantom for the validation of deformation algorithms and 4D dose calculations

    NASA Astrophysics Data System (ADS)

    Szegedi, M.; Rassiah-Szegedi, P.; Fullerton, G.; Wang, B.; Salter, B.

    2010-07-01

    The purpose of this study is to design a real-tissue phantom for use in the validation of deformation algorithms. A phantom motion controller that runs sinusoidal and non-regular patient-based breathing pattern, via a piston, was applied to porcine liver tissue. It was regulated to simulate movement ranges similar to recorded implanted liver markers from patients. 4D CT was applied to analyze deformation. The suitability of various markers in the liver and the position reproducibility of markers and of reference points were studied. The similarity of marker motion pattern in the liver phantom and in real patients was evaluated. The viability of the phantom over time and its use with electro-magnetic tracking devices were also assessed. High contrast markers, such as carbon markers, implanted in the porcine liver produced less image artifacts on CT and were well visualized compared to metallic ones. The repositionability of markers was within a measurement accuracy of ±2 mm. Similar anatomical patient motions were reproducible up to elongations of 3 cm for a time period of at least 90 min. The phantom is compatible with electro-magnetic tracking devices and 4D CT. The phantom motion is reproducible and simulates realistic patient motion and deformation. The ability to carry out voxel-based tracking allows for the evaluation of deformation algorithms in a controlled environment with recorded patient traces. The phantom is compatible with all therapy devices clinically encountered in our department.

  4. Novel electro-optical coupling technique for magnetic resonance-compatible positron emission tomography detectors.

    PubMed

    Olcott, Peter D; Peng, Hao; Levin, Craig S

    2009-01-01

    A new magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL) diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  5. The magnitude of variability produced by methods used to estimate annual stormwater contaminant loads for highly urbanised catchments.

    PubMed

    Beck, H J; Birch, G F

    2013-06-01

    Stormwater contaminant loading estimates using event mean concentration (EMC), rainfall/runoff relationship calculations and computer modelling (Model of Urban Stormwater Infrastructure Conceptualisation--MUSIC) demonstrated high variability in common methods of water quality assessment. Predictions of metal, nutrient and total suspended solid loadings for three highly urbanised catchments in Sydney estuary, Australia, varied greatly within and amongst methods tested. EMC and rainfall/runoff relationship calculations produced similar estimates (within 1 SD) in a statistically significant number of trials; however, considerable variability within estimates (∼50 and ∼25 % relative standard deviation, respectively) questions the reliability of these methods. Likewise, upper and lower default inputs in a commonly used loading model (MUSIC) produced an extensive range of loading estimates (3.8-8.3 times above and 2.6-4.1 times below typical default inputs, respectively). Default and calibrated MUSIC simulations produced loading estimates that agreed with EMC and rainfall/runoff calculations in some trials (4-10 from 18); however, they were not frequent enough to statistically infer that these methods produced the same results. Great variance within and amongst mean annual loads estimated by common methods of water quality assessment has important ramifications for water quality managers requiring accurate estimates of the quantities and nature of contaminants requiring treatment.

  6. Ground-based studies of tropisms in hardware developed for the European Modular Cultivation System (EMCS)

    NASA Astrophysics Data System (ADS)

    Correll, Melanie J.; Edelmann, Richard E.; Hangarter, Roger P.; Mullen, Jack L.; Kiss, John Z.

    Phototropism and gravitropism play key roles in the oriented growth of roots in flowering plants. In blue or white light, roots exhibit negative phototropism, but red light induces positive phototropism in Arabidopsis roots. The blue-light response is controlled by the phototropins while the red-light response is mediated by the phytochrome family of photoreceptors. In order to better characterize root phototropism, we plan to perform experiments in microgravity so that this tropism can be more effectively studied without the interactions with the gravity response. Our experiments are to be performed on the European Modular Cultivation System (EMCS), which provides an incubator, lighting system, and high resolution video that are on a centrifuge palette. These experiments will be performed at μg, 1g (control) and fractional g-levels. In order to ensure success of this mission on the International Space Station, we have been conducting ground-based studies on growth, phototropism, and gravitropism in experimental unique equipment (EUE) that was designed for our experiments with Arabidopsis seedlings. Currently, the EMCS and our EUE are scheduled for launch on space shuttle mission STS-121. This project should provide insight into how the blue- and red-light signaling systems interact with each other and with the gravisensing system.

  7. Hydration behaviour of food grains and modelling their moisture pick up as per Peleg's equation: Part I. Cereals.

    PubMed

    Vasudeva, Singh; Vishwanathan, K H; Aswathanarayana, K N; Indhudhara Swamy, Y M

    2010-01-01

    Cereals and millets generally hydrate at a moderate rate and their hydration behaviour differs in native and in processed state. The study was on the hydration of paddy, milled rice, parboiled rice, wheat, millets and equilibrium moisture content (EMC) on soaking at room temperature. Paddy hydrated very slowly, hydration rate was slow in brown rice but fast in milled rice and highest in waxy rice. In most of the rice varieties, maximum absorption occurred at the end of 30 min. In wheat hydration rate was slow and its EMC was highest (43%). Maize grits of big size hydrated slowly compared to small grits. In coarse cereals EMC varied from 28 to 38%. Foxtail millet hydration was slow whereas that of finger millet was fast. The data were tested on the Peleg's equation, which gave a reasonable fit to experimental data. Peleg's constants k1 and k2 were calculated for the above grains and their hydration behaviour has been predicted. The model fitted very well to milled rice hydration data where the coefficient of variance ranged from 0.9982 to 0.9995. With exception in some millet the hydration data fitted well with the Peleg's equation. Generalized equations have been formulated for prediction of moisture content of cereals and millets.

  8. Effect of storage temperatures and humidity on proximate composition, peroxide value and iodine value of raw cashew nuts.

    PubMed

    Ajith, Sabna; Pramod, S; Prabha Kumari, C; Potty, V P

    2015-07-01

    The equilibrium moisture content (EMC) of raw cashew nuts (RCN) were determined using the standard static gravimetric method at 30 °C, 40 °C and 50 °C for relative humidity (RH) ranging from 43 to 90 %. The proximate composition analysis, peroxide value and iodine value of RCN were assessed at this equilibrium stage. The RCN kept under the humidity of 86 and 90 percentage at all studied temperatures developed mold growth within 24-48 h of time. The better storage condition assessed for raw cashew nut is 67 % of RH at 30 °C and the values obtained for EMC, proximate composition analysis, peroxide value and iodine value are within the same range as observed with harvested RCN. Highlights • Raw cashew nut storage condition identified • It was analysed with different temperature (30 (°)C, 40 (°)C and 50 (°)C) and relative humidity (43 %-90 %) • Better storage condition for raw cashew nut is in 67 % of RH at 30 (°)C • In this condition the EMC was 8.11 % as within the range of moisture in harvested RCN.

  9. An age-related change in susceptibility of rat brain to encephalomyocarditis virus infection

    PubMed Central

    IKEGAMI, HISASHI; TAKEDA, MAKIO; DOI, KUNIO

    1997-01-01

    Rats were inoculated intraperitoneally (i.p.) or intracerebrally (i.c.) with 1 × 104 plaque forming units (PFU)/animal of the D variant of encephalomyocarditis virus (EMC-D) at 2, 4, 7, 14, 28 or 56 days of age for virological and histopathological examination. In the i.p.-inoculation study, neither viral replication nor lesions were detected in the animals inoculated at 28 and 56 days of age. In the animals inoculated when younger than 14 days of age, lesions were restricted to the brain although viral replication was detected in the brain, heart and pancreas. The brain lesions were characterized by acute meningoencephalitis with neuronal necrosis in the cerebral cortex, hippocampus and thalamus, and viral RNA was detected in degenerated and/or intact neurons. In the i.c.-inoculation study, similar age-related changes in susceptibility of rat brain to EMC-D infection were observed, but a minor difference was that viral replication and lesions were still detected in the hippocampus of some animals inoculated at 28 days of age. These results suggest that an age-related decrease in the susceptibility of rat brain to EMC virus infection may reflect an age-related change in the susceptibility of neurons themselves as well as in maturation of the immune system. PMID:9203984

  10. Characterization of silica particles modified with γ-methacryloxypropyltrimethoxysilane

    NASA Astrophysics Data System (ADS)

    Jiang, Jun; Wang, Wang; Shen, Haiying; Wang, Jiamin; Cao, Jinzhen

    2017-03-01

    The surface of hydrophilic silica particles was modified with different concentrations (2, 4, 6, 8 and 10%) of γ-methacryloxypropyltrimethoxysilane (MPTS). The hydrophobicity and hygroscopicity of unmodified and modified silica were investigated through water contact angle (WCA) tests and dynamic vapor sorption (DVS) method, respectively. The results showed that the surface properties of silica were closely related with the MPTS concentration. Within the range of MPTS concentration applied, 8% MPTS modified silica showed the least aggregation. With the increasing MPTS concentration, the WCAs on modified silica film increased correspondingly, and finally exceeded 90° at 6% and 8% concentrations. The equilibrium moisture contents (EMCs) of modified silica also decreased with the increasing MPTS concentration. The improvement on hydrophobicity can be correlated with the reduction of residual hydroxyl groups (-OH) on modified silica. The self-condensation of MPTS began to occur at concentrations higher than 4%, especially at 8%. Owing to this effect, the modified silica with 8% MPTS showed a slightly higher EMC than 6% MPTS within low relative humidity (RH) range up to 40%. At a higher RH ranging from 40 to 90%, 8% group showed the lowest EMCs because of its highest hydrophobicity and low specific surface area. A mechanism concerning the MPTS modification of silica was also proposed in this study based on the research results.

  11. Lithium ion solvation and diffusion in bulk organic electrolytes from first-principles and classical reactive molecular dynamics.

    PubMed

    Ong, Mitchell T; Verners, Osvalds; Draeger, Erik W; van Duin, Adri C T; Lordi, Vincenzo; Pask, John E

    2015-01-29

    Lithium-ion battery performance is strongly influenced by the ionic conductivity of the electrolyte, which depends on the speed at which Li ions migrate across the cell and relates to their solvation structure. The choice of solvent can greatly impact both the solvation and diffusivity of Li ions. In this work, we used first-principles molecular dynamics to examine the solvation and diffusion of Li ions in the bulk organic solvents ethylene carbonate (EC), ethyl methyl carbonate (EMC), and a mixture of EC and EMC. We found that Li ions are solvated by either carbonyl or ether oxygen atoms of the solvents and sometimes by the PF6(-) anion. Li(+) prefers a tetrahedrally coordinated first solvation shell regardless of which species are involved, with the specific preferred solvation structure dependent on the organic solvent. In addition, we calculated Li diffusion coefficients in each electrolyte, finding slightly larger diffusivities in the linear carbonate EMC compared to the cyclic carbonate EC. The magnitude of the diffusion coefficient correlates with the strength of Li(+) solvation. Corresponding analysis for the PF6(-) anion shows greater diffusivity associated with a weakly bound, poorly defined first solvation shell. These results can be used to aid in the design of new electrolytes to improve Li-ion battery performance.

  12. Comparing deep neural network and other machine learning algorithms for stroke prediction in a large-scale population-based electronic medical claims database.

    PubMed

    Chen-Ying Hung; Wei-Chen Chen; Po-Tsun Lai; Ching-Heng Lin; Chi-Chun Lee

    2017-07-01

    Electronic medical claims (EMCs) can be used to accurately predict the occurrence of a variety of diseases, which can contribute to precise medical interventions. While there is a growing interest in the application of machine learning (ML) techniques to address clinical problems, the use of deep-learning in healthcare have just gained attention recently. Deep learning, such as deep neural network (DNN), has achieved impressive results in the areas of speech recognition, computer vision, and natural language processing in recent years. However, deep learning is often difficult to comprehend due to the complexities in its framework. Furthermore, this method has not yet been demonstrated to achieve a better performance comparing to other conventional ML algorithms in disease prediction tasks using EMCs. In this study, we utilize a large population-based EMC database of around 800,000 patients to compare DNN with three other ML approaches for predicting 5-year stroke occurrence. The result shows that DNN and gradient boosting decision tree (GBDT) can result in similarly high prediction accuracies that are better compared to logistic regression (LR) and support vector machine (SVM) approaches. Meanwhile, DNN achieves optimal results by using lesser amounts of patient data when comparing to GBDT method.

  13. Neutron observables from inclusive lepton scattering on nuclei

    NASA Astrophysics Data System (ADS)

    Rinat, A. S.; Taragin, M. F.

    2010-07-01

    We analyze new data from Thomas Jefferson National Accelerator Facility (JLab) for inclusive electron scattering on various targets. Computed and measured total inclusive cross sections in the range 0.3≲x≲0.95 show reasonable agreement on a logarithmic scale for all targets. However, closer inspection of the quasielastic components reveals serious discrepancies. European Muon Collaboration (EMC) ratios with conceivably smaller systematic errors fare the same. As a consequence, the new data do not enable the extraction of the magnetic form factor GMn and the structure function F2n of the neutron, although the application of exactly the same analysis to older data had been successful. We incorporate in the above analysis older CLAS Collaboration data on F22H. Removal of some scattered points from those makes it appear possible to obtain the desired neutron information. We compare our results with others from alternative sources. Special attention is paid to the A=3 isodoublet cross sections and EMC ratios. Present data exist only for He3, but the available input in combination with charge symmetry enables computations for H3. Their average is the computed isoscalar part and is compared with the empirical modification of He3 EMC ratios toward a fictitious A=3 isosinglet.

  14. Multigen-2 Pre-Flight Testing: Science Testing Unit (STU) and Stowage Conditions

    NASA Astrophysics Data System (ADS)

    Kittang, A.-I.; Kvaloy, B.; Berg, C.; Rakvaag, G.; Iversen, T.-H.

    2008-06-01

    The Multigen-2 experiment Science Testing Unit (STU) proved to be a useful tool in optimizing experiment environment settings for cultivation of Arabidopsis thaliana (Col-0) in the European Modular Cultivation System (EMCS). By using the EMCS Experiment Reference Model (ERM); light, temperature and air flow regimes for optimal growth could be tested. Healthy seedlings were obtained using the STU#2 and STU#3 in the EMCS ERM. It was concluded that the Experiment Container Development Kit (ECDK) is unsuitable for the Multigen-2 testing due to limitation in the ECDK temperature control. The results from the stowage condition tests showed that the selected growth medium (agar) can be used after 3 months at +4°C. The seeds show a germination rate of ≥80% after sterilisation and stowed for 5 months. The Multigen-2 plant samples will be fixed in RNA later and stored at - 80 °C. Three methods with different RNA isolation kits showed that the Qiagen kit (#74904) gave the highest amount and the best quality of Total RNA from RNA Later and frozen samples. The amount of plant material from one cultivation chamber gives two RNA isolations. Each of the isolations gives Total RNA sufficient for at least two microarray analyses.

  15. Explanatory model of emotional-cognitive variables in school mathematics performance: a longitudinal study in primary school.

    PubMed

    Cerda, Gamal; Pérez, Carlos; Navarro, José I; Aguilar, Manuel; Casas, José A; Aragón, Estíbaliz

    2015-01-01

    This study tested a structural model of cognitive-emotional explanatory variables to explain performance in mathematics. The predictor variables assessed were related to students' level of development of early mathematical competencies (EMCs), specifically, relational and numerical competencies, predisposition toward mathematics, and the level of logical intelligence in a population of primary school Chilean students (n = 634). This longitudinal study also included the academic performance of the students during a period of 4 years as a variable. The sampled students were initially assessed by means of an Early Numeracy Test, and, subsequently, they were administered a Likert-type scale to measure their predisposition toward mathematics (EPMAT) and a basic test of logical intelligence. The results of these tests were used to analyse the interaction of all the aforementioned variables by means of a structural equations model. This combined interaction model was able to predict 64.3% of the variability of observed performance. Preschool students' performance in EMCs was a strong predictor for achievement in mathematics for students between 8 and 11 years of age. Therefore, this paper highlights the importance of EMCs and the modulating role of predisposition toward mathematics. Also, this paper discusses the educational role of these findings, as well as possible ways to improve negative predispositions toward mathematical tasks in the school domain.

  16. SU-E-T-344: Validation and Clinical Experience of Eclipse Electron Monte Carlo Algorithm (EMC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokharel, S; Rana, S

    2014-06-01

    Purpose: The purpose of this study is to validate Eclipse Electron Monte Carlo (Algorithm for routine clinical uses. Methods: The PTW inhomogeneity phantom (T40037) with different combination of heterogeneous slabs has been CT-scanned with Philips Brilliance 16 slice scanner. The phantom contains blocks of Rando Alderson materials mimicking lung, Polystyrene (Tissue), PTFE (Bone) and PMAA. The phantom has 30×30×2.5 cm base plate with 2cm recesses to insert inhomogeneity. The detector systems used in this study are diode, tlds and Gafchromic EBT2 films. The diode and tlds were included in CT scans. The CT sets are transferred to Eclipse treatment planningmore » system. Several plans have been created with Eclipse Monte Carlo (EMC) algorithm 11.0.21. Measurements have been carried out in Varian TrueBeam machine for energy from 6–22mev. Results: The measured and calculated doses agreed very well for tissue like media. The agreement was reasonably okay for the presence of lung inhomogeneity. The point dose agreement was within 3.5% and Gamma passing rate at 3%/3mm was greater than 93% except for 6Mev(85%). The disagreement can reach as high as 10% in the presence of bone inhomogeneity. This is due to eclipse reporting dose to the medium as opposed to the dose to the water as in conventional calculation engines. Conclusion: Care must be taken when using Varian Eclipse EMC algorithm for dose calculation for routine clinical uses. The algorithm dose not report dose to water in which most of the clinical experiences are based on rather it just reports dose to medium directly. In the presence of inhomogeneity such as bone, the dose discrepancy can be as high as 10% or even more depending on the location of normalization point or volume. As Radiation oncology as an empirical science, care must be taken before using EMC reported monitor units for clinical uses.« less

  17. A comparative study of the grain-size distribution of surface dust and stormwater runoff quality on typical urban roads and roofs in Beijing, China.

    PubMed

    Shen, Zhenyao; Liu, Jin; Aini, Guzhanuer; Gong, Yongwei

    2016-02-01

    The deposition of pollutants on impervious surfaces is a serious problem associated with rapid urbanization, which results in non-point-source pollution. Characterizing the build-up and wash-off processes of pollutants in urban catchments is essential for urban planners. In this paper, the spatial variation and particle-size distributions of five heavy metals and two nutrients in surface dust were analyzed, and the runoff water first-flush effect (FF30) and event-mean concentrations (EMCs) of 10 common constituents were characterized. The relationships between runoff variables and stormwater characteristics were examined from three typical urban impervious surfaces in Beijing, China. Dust on road surfaces with smaller grain sizes had higher pollutant concentrations, whereas concentrations of Mn, Zn, Fe, and TP in roof surface dust increased with grain size. Particles with grain sizes of 38-74 and 125-300 μm contributed most to the total pollutant load in roads, while particles with the smallest grain sizes (<38 μm) contributed most on roofs (23.46-41.71 %). Event-mean concentrations (EMCs) and FF30 values for most runoff pollutants tended to be higher on roofs than on roads. The maximum intensity (I max) and the antecedent dry days (ADD) were critical parameters for EMCs in roads, while ADD was the only dominant parameter for EMCs on our studied roof. The rainfall intensity (RI) and maximum intensity (I max) were found to be the parameters with the strongest correlation to the first-flush effect on both roads and roofs. Significant correlations of total suspended solids (TSS) concentration in runoff with grain-size fractions of surface dust indicated that coarser particles (74-300 μm) are most likely to contribute to the solid-phase pollutants, and finer particles (<38 μm) are likely the main source of dissolved pollutants.

  18. Key factors affecting urban runoff pollution under cold climatic conditions

    NASA Astrophysics Data System (ADS)

    Valtanen, Marjo; Sillanpää, Nora; Setälä, Heikki

    2015-10-01

    Urban runoff contains various pollutants and has the potential of deteriorating the quality of aquatic ecosystems. In this study our objective is to shed light on the factors that control the runoff water quality in urbanized catchments. The effects of runoff event characteristics, land use type and catchment imperviousness on event mass loads (EML) and event mean concentrations (EMC) were studied during warm and cold periods in three study catchments (6.1, 6.5 and 12.6 ha in size) in the city of Lahti, Finland. Runoff and rainfall were measured continuously for two years at each catchment. Runoff samples were taken for total nutrients (tot-P and tot-N), total suspended solids (TSS), heavy metals (Zn, Cr, Al, Co, Ni, Cu, Pb, Mn) and total organic carbon (TOC). Stepwise multiple linear regression analysis (SMLR) was used to identify general relationships between the following variables: event water quality, runoff event characteristics and catchment characteristics. In general, the studied variables explained 50-90% of the EMLs but only 30-60% of the EMCs, with runoff duration having an important role in most of the SMLR models. Mean runoff intensity or peak flow was also often included in the runoff quality models. Yet, the importance (being the first, second or third best) and role (negative or positive impact) of the explanatory variables varied between the cold and warm period. Land use type often explained cold period concentrations, but imperviousness alone explained EMCs weakly. As for EMLs, the influence of imperviousness and/or land use was season and pollutant dependent. The study suggests that pollutant loads can be - throughout the year - adequately predicted by runoff characteristics given that seasonal differences are taken into account. Although pollutant concentrations were sensitive to variation in seasonal and catchment conditions as well, the accurate estimation of EMCs would require a more complete set of explanatory factors than used in this study.

  19. Quality of care for patients with type 2 diabetes mellitus in the Netherlands and the United States: a comparison of two quality improvement programs.

    PubMed

    Valk, Gerlof D; Renders, Carry M; Kriegsman, Didi M W; Newton, Katherine M; Twisk, Jos W R; van Eijk, Jacques Th M; van der Wal, Gerrit; Wagner, Edward H

    2004-08-01

    To assess differences in diabetes care and patient outcomes by comparing two multifaceted quality improvement programs in two different countries, and to increase knowledge of effective elements of such programs. Primary care in the ExtraMural Clinic (EMC) of the Department of General Practice of the Vrije Universiteit in Amsterdam, the Netherlands, and the Group Health Cooperative (GHC), a group-model health maintenance organization (HMO) in western Washington State in the United States. Data were collected from 1992 to 1997. In this observational study two diabetes cohorts in which a quality improvement program was implemented were compared. Both programs included a medical record system, clinical practice guidelines, physician educational meetings, audit, and feedback. Only the Dutch program (EMC) included guidelines on the structure of diabetes care and a recall system. Only the GHC program included educational outreach visits, formation of multidisciplinary teams, and patient self-management support. Included were 379 EMC patients, and 2,119 GHC patients with type 2 diabetes mellitus. Main process outcomes were: annual number of diabetes visits, and number of HbA1c and blood lipid measurements. Main patient outcomes were HbA1c and blood lipid levels. Multilevel analysis was used to adjust for dependency between repeated observations within one patient and for clustering of patients within general practices. In the EMC process outcomes and glycemic control improved more than at GHC, however, GHC had better baseline measures. There were no differences between programs on blood lipid control. During follow-up, intensification of pharmacotherapy was noted at both sites. Differences noted between programs were in line with differences in diabetes guidelines. Following implementation of guidelines and organizational improvement efforts, change occurred primarily in the process outcomes, rather than in the patient outcomes. Although much effort was put into improving process and patient outcomes, both complex programs still showed only moderate effects.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carver, R; Popple, R; Benhabib, S

    Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10{sup 9}),more » resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT.« less

Top