Sample records for electron gun system

  1. Carbon Nanotube Electron Gun

    NASA Technical Reports Server (NTRS)

    Ribaya, Bryan P. (Inventor); Nguyen, Cattien V. (Inventor)

    2013-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  2. Carbon nanotube electron gun

    NASA Technical Reports Server (NTRS)

    Nguyen, Cattien V. (Inventor); Ribaya, Bryan P. (Inventor)

    2010-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  3. An electrostatically and a magnetically confined electron gun lens system

    NASA Technical Reports Server (NTRS)

    Bernius, Mark T.; Man, Kin F.; Chutjian, Ara

    1988-01-01

    Focal properties, electron trajectory calculations, and geometries are given for two electron 'gun' lens systems that have a variety of applications in, for example, electron-neutral and electron-ion scattering experiments. One nine-lens system utilizes only electrostatic confinement and is capable of focusing electrons onto a fixed target with extremely small divergence angles, over a range of final energies 1-790 eV. The second gun lens system is a simpler three-lens system suitable for use in a uniform, solenoidal magnetic field. While the focusing properties of such a magnetically confined lens systenm are simpler to deal with, the system does illustrate features of electron extraction and Brillouin flow that have not been suitably emphasized in the literature.

  4. Magnetron Electron Gun,

    DTIC Science & Technology

    1980-05-23

    ULMAGNETRON ELECTRON GUN . (U) .Ay G0 A L GOLOENBERG, T B PANKRATOVA UNCLASSIFIED FTD..In(RS)T41896-?9 4 __ ihD - -111113 MICROCOPY RESOLUTION TEST...CHART NATIONAL BUREAU OF STANDARD 1961 A -_"D-I-D ,RS)T-18q6-79 v FOREIGN TECHNOLOGY DIVISION MAGNETRON ELECTRON GUN by A. L. Gol’denberg, T. B...VISION. WP.AP6. OHIO. FTD -ID(RS)T-1396-79 Date z.-.:a’,-lq -,o • 110ewm /A Is a, -D r.l MAGNETRON ELECTRON GUN A. L. Gol’denberg, T. B. Pankratova and M

  5. Unbalanced field RF electron gun

    DOEpatents

    Hofler, Alicia

    2013-11-12

    A design for an RF electron gun having a gun cavity utilizing an unbalanced electric field arrangement. Essentially, the electric field in the first (partial) cell has higher field strength than the electric field in the second (full) cell of the electron gun. The accompanying method discloses the use of the unbalanced field arrangement in the operation of an RF electron gun in order to accelerate an electron beam.

  6. Note: Design of transverse electron gun for electron beam based reactive evaporation system.

    PubMed

    Maiti, Namita; Barve, U D; Bhatia, M S; Das, A K

    2011-05-01

    In this paper design of a 10 kV, 10 kW transverse electron gun, suitable for reactive evaporation, supported by simulation and modeling, is presented. Simulation of the electron beam trajectory helps in locating the emergence aperture after 90° bend and also in designing the crucible on which the beam is finally incident after 270° bend. The dimension of emergence aperture plays a vital role in designing the differential pumping system between the gun chamber and the substrate chamber. Experimental validation is done for beam trajectory by piercing a stainless steel plate at 90° position which is kept above the crucible.

  7. Simulations of Gaussian electron guns for RHIC electron lens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, A.

    Simulations of two versions of the electron gun for RHIC electron lens are presented. The electron guns have to generate an electron beam with Gaussian radial profile of the electron beam density. To achieve the Gaussian electron emission profile on the cathode we used a combination of the gun electrodes and shaping of the cathode surface. Dependence of electron gun performance parameters on the geometry of electrodes and the margins for electrodes positioning are presented.

  8. Development of plasma cathode electron guns

    NASA Astrophysics Data System (ADS)

    Oks, Efim M.; Schanin, Peter M.

    1999-05-01

    The status of experimental research and ongoing development of plasma cathode electron guns in recent years is reviewed, including some novel upgrades and applications to various technological fields. The attractiveness of this kind of e-gun is due to its capability of creating high current, broad or focused beams, both in pulsed and steady-state modes of operation. An important characteristic of the plasma cathode electron gun is the absence of a thermionic cathode, a feature which leads to long lifetime and reliable operation even in the presence of aggressive background gas media and at fore-vacuum gas pressure ranges such as achieved by mechanical pumps. Depending on the required beam parameters, different kinds of plasma discharge systems can be used in plasma cathode electron guns, such as vacuum arcs, constricted gaseous arcs, hollow cathode glows, and two kinds of discharges in crossed E×B fields: Penning and magnetron. At the present time, plasma cathode electron guns provide beams with transverse dimension from fractional millimeter up to about one meter, beam current from microamperes to kiloamperes, beam current density up to about 100 A/cm2, pulse duration from nanoseconds to dc, and electron energy from several keV to hundreds of keV. Applications include electron beam melting and welding, surface treatment, plasma chemistry, radiation technologies, laser pumping, microwave generation, and more.

  9. ECR ion source with electron gun

    DOEpatents

    Xie, Z.Q.; Lyneis, C.M.

    1993-10-26

    An Advanced Electron Cyclotron Resonance ion source having an electron gun for introducing electrons into the plasma chamber of the ion source is described. The ion source has a injection enclosure and a plasma chamber tank. The plasma chamber is defined by a plurality of longitudinal magnets. The electron gun injects electrons axially into the plasma chamber such that ionization within the plasma chamber occurs in the presence of the additional electrons produced by the electron gun. The electron gun has a cathode for emitting electrons therefrom which is heated by current supplied from an AC power supply while bias potential is provided by a bias power supply. A concentric inner conductor and outer conductor carry heating current to a carbon chuck and carbon pusher which hold the cathode in place and also heat the cathode. In the Advanced Electron Cyclotron Resonance ion source, the electron gun replaces the conventional first stage used in prior electron cyclotron resonance ion generators. 5 figures.

  10. Wisconsin SRF Electron Gun Commissioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisognano, Joseph J.; Bissen, M.; Bosch, R.

    The University of Wisconsin has completed fabrication and commissioning of a low frequency (199.6 MHz) superconducting electron gun based on a quarter wave resonator (QWR) cavity. Its concept was optimized to be the source for a CW free electron laser facility. The gun design includes active tuning and a high temperature superconducting solenoid. We will report on the status of the Wisconsin SRF electron gun program, including commissioning experience and first beam measurements.

  11. Self-bunching electron guns

    NASA Astrophysics Data System (ADS)

    Mako, Frederick M.; Len, L. K.

    1999-05-01

    We report on three electron gun projects that are aimed at power tube and injector applications. The purpose of the work is to develop robust electron guns which produce self-bunched, high-current-density beams. We have demonstrated, in a microwave cavity, self-bunching, cold electron emission, long life, and tolerance to contamination. The cold process is based on secondary electron emission. FMT has studied using simulation codes the resonant bunching process which gives rise to high current densities (0.01-5 kA/cm2), high charge bunches (up to 500 nC/bunch), and short pulses (1-100 ps) for frequencies from 1 to 12 GHz. The beam pulse width is nominally ˜5% of the rf period. The first project is the L-Band Micro-Pulse Gun (MPG). Measurements show ˜40 ps long micro-bunches at ˜20 A/cm2 without contamination due to air exposure. Lifetime testing has been carried out for about 18 months operating at 1.25 GHz for almost 24 hours per day at a repetition rate of 300 Hz and 5 μs-long macro-pulses. Approximately 5.8×1013 micro-bunches or 62,000 coulombs have passed through this gun and it is still working fine. The second project, the S-Band MPG, is now operational. It is functioning at a frequency of 2.85 GHz, a repetition rate of 30 Hz, with a 2 μs-long macro-pulse. It produces about 45 A in the macro-pulse. The third project is a 34.2 GHz frequency-multiplied source driven by an X-Band MPG. A point design was performed at an rf output power of 150 MW at 34.2 GHz. The resulting system efficiency is 53% and the gain is 60 dB. The system efficiency includes the input cavity efficiency, input driver efficiency (a 50 MW klystron at 11.4 GHz), output cavity efficiency, and the post-acceleration efficiency.

  12. ECR ion source with electron gun

    DOEpatents

    Xie, Zu Q.; Lyneis, Claude M.

    1993-01-01

    An Advanced Electron Cyclotron Resonance ion source (10) having an electron gun (52) for introducing electrons into the plasma chamber (18) of the ion source (10). The ion source (10) has a injection enclosure (12) and a plasma chamber tank (14). The plasma chamber (18) is defined by a plurality of longitudinal magnets (16). The electron gun (52) injects electrons axially into the plasma chamber (18) such that ionization within the plasma chamber (18) occurs in the presence of the additional electrons produced by the electron gun (52). The electron gun (52) has a cathode (116) for emitting electrons therefrom which is heated by current supplied from an AC power supply (96) while bias potential is provided by a bias power supply (118). A concentric inner conductor (60) and Outer conductor (62) carry heating current to a carbon chuck (104) and carbon pusher (114) Which hold the cathode (116) in place and also heat the cathode (16). In the Advanced Electron Cyclotron Resonance ion source (10), the electron gun (52) replaces the conventional first stage used in prior art electron cyclotron resonance ion generators.

  13. Superconducting 112 MHz QWR electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belomestnykh, S.; Ben-Zvi, I.; Boulware, C.H.

    Brookhaven National Laboratory and Niowave, Inc. have designed and fabricated a superconducting 112 MHz quarter-wave resonator (QWR) electron gun. The first cold test of the QWR cryomodule has been completed at Niowave. The paper describes the cryomodule design, presents the cold test results, and outline plans to upgrade the cryomodule. Future experiments include studies of different photocathodes and use for the coherent electron cooling proof-of-principle experiment. Two cathode stalk options, one for multi-alkali photocathodes and the other one for a diamond-amplified photocathode, are discussed. A quarter-wave resonator concept of superconducting RF (SRF) electron gun was proposed at BNL for electronmore » cooling hadron beams in RHIC. QWRs can be made sufficiently compact even at low RF frequencies (long wavelengths). The long wavelength allows to produce long electron bunches, thus minimizing space charge effects and enabling high bunch charge. Also, such guns should be suitable for experiments requiring high average current electron beams. A 112 MHz QWR gun was designed, fabricated, and cold-tested in collaboration between BNL and Niowave. This is the lowest frequency SRF gun ever tested successfully. In this paper we describe the gun design and fabrication, present the cold test results, and outline our plans. This gun will also serve as a prototype for a future SRF gun to be used for coherent electron cooling of hadrons in eRHIC.« less

  14. RF Guns for Generation of Polarized Electron Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J.E.; Brachmann, A.; Dowell, D.H.

    2005-11-09

    Several accelerators, including the SLC, JLAB, Mainz, Bates/MIT, and Bonn have successfully operated for medium and high energy physics experiments using polarized electron beams generated by dc-biased guns employing GaAs photocathodes. Since these guns have all used a bias on the order of 100 kV, the longitudinal emittance of the extracted bunch is rather poor. Downstream rf bunching systems increase the transverse emittance. An rf gun with a GaAs photocathode would eliminate the need for separate rf bunchers, resulting in a simpler injection system. In addition, the thermal emittance of GaAs-type cathodes is significantly lower than for other photocathode materials.more » The environmental requirements for operating activated GaAs photocathodes cannot be met by rf guns as currently designed and operated. These requirements, including limits on vacuum and electron back bombardment, are discussed in some detail. Modifications to actual and proposed rf gun designs that would allow these requirements to be met are presented.« less

  15. Ultra high vacuum test setup for electron gun

    NASA Astrophysics Data System (ADS)

    Pandiyar, M. L.; Prasad, M.; Jain, S. K.; Kumar, R.; Hannurkar, P. R.

    2008-05-01

    Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and vapour pressure of cathode surface material at high temperature studies will further help in design and development of high power electron gun The UHV electron gun test setup consists of Turbo Molecular Pump (TMP), Sputter Ion Pump (SIP), pressure gauge, high voltage and cathode power supplies, current measurement device, solenoid magnet and its power supply, residual gas analyser etc. The ultimate vacuum less than 2×10-9 mbar was achieved. This paper describes the UHV test setup for electron gun testing.

  16. A novel electron gun for inline MRI-linac configurations.

    PubMed

    Constantin, Dragoş E; Holloway, Lois; Keall, Paul J; Fahrig, Rebecca

    2014-02-01

    This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Simple electron gun geometry modifications of a Varian 600 C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600 C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ± 15 cm along the axis of the 0.5 T magnet without capture

  17. A novel electron gun for inline MRI-linac configurations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constantin, Dragoş E., E-mail: dragos.constantin@varian.com; Fahrig, Rebecca; Holloway, Lois

    2014-02-15

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered andmore » solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0

  18. A novel electron gun for inline MRI-linac configurations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constantin, Dragoş E., E-mail: dragos.constantin@varian.com; Fahrig, Rebecca; Holloway, Lois

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered andmore » solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0

  19. ELECTRON GUN

    DOEpatents

    Christofilos, N.C.; Ehlers, K.W.

    1960-04-01

    A pulsed electron gun capable of delivering pulses at voltages of the order of 1 mv and currents of the order of 100 amperes is described. The principal novelty resides in a transformer construction which is disposed in the same vacuum housing as the electron source and accelerating electrode structure of the gun to supply the accelerating potential thereto. The transformer is provided by a plurality of magnetic cores disposed in circumferentially spaced relation and having a plurality of primary windings each inductively coupled to a different one of the cores, and a helical secondary winding which is disposed coaxially of the cores and passes therethrough in circumferential succession. Additional novelty resides in the disposition of the electron source cathode filament input leads interiorly of the transformer secondary winding which is hollow, as well as in the employment of a half-wave filament supply which is synchronously operated with the transformer supply such that the transformer is pulsed during the zero current portions of the half-wave cycle.

  20. Analysis of magnetically immersed electron guns with non-adiabatic fields.

    PubMed

    Pikin, Alexander; Alessi, James G; Beebe, Edward N; Raparia, Deepak; Ritter, John

    2016-11-01

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams with high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map, different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. The tests' results of a non-adiabatic electron gun with modified magnetic field are presented.

  1. Numerical modelling of the CEBAF electron gun with EGUN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Philippe Liger; Geoffrey Krafft

    1990-09-10

    The electron source used in the injector for the CEBAF accelerator is a Hermosa electron gun with a 2 mm diameter cathode and a control electrode. It produces a 100 keV electron beam to be focused on the first of two apertures which comprise an emittance filter. A normalized emittance of less than {pi} mm mrad at 1.2 mA is set by the requirements of the final beam from the CEBAF linac, since downstream of the filter, a system of two choppers and a third aperture removes 5/6 of the current. In addition, for RF test purposes a higher currentmore » of about 5 mA is needed, possibly at higher emittance. This paper presents a way of calculating the characteristics of the CEBAF electron gun with the gun design code EGUN, and the accuracy of the results is discussed. The transverse shape of the beam delivered by the gun has been observed, and its current measured. A halo around the beam has been seen, and the calculations can reproduce this effect.« less

  2. Analysis of magnetically immersed electron guns with non-adiabatic fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, Alexander; Alessi, James G.; Beebe, Edward N.

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams withmore » high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. In conclusion, the tests results of non-adiabatic electron gun with modified magnetic field are presented.« less

  3. Analysis of magnetically immersed electron guns with non-adiabatic fields

    DOE PAGES

    Pikin, Alexander; Alessi, James G.; Beebe, Edward N.; ...

    2016-11-08

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams withmore » high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. In conclusion, the tests results of non-adiabatic electron gun with modified magnetic field are presented.« less

  4. Toward a terahertz-driven electron gun

    PubMed Central

    Huang, W. Ronny; Nanni, Emilio A.; Ravi, Koustuban; Hong, Kyung-Han; Fallahi, Arya; Wong, Liang Jie; Keathley, Phillip D.; Zapata, Luis E.; Kärtner, Franz X.

    2015-01-01

    Femtosecond electron bunches with keV energies and eV energy spread are needed by condensed matter physicists to resolve state transitions in carbon nanotubes, molecular structures, organic salts, and charge density wave materials. These semirelativistic electron sources are not only of interest for ultrafast electron diffraction, but also for electron energy-loss spectroscopy and as a seed for x-ray FELs. Thus far, the output energy spread (hence pulse duration) of ultrafast electron guns has been limited by the achievable electric field at the surface of the emitter, which is 10 MV/m for DC guns and 200 MV/m for RF guns. A single-cycle THz electron gun provides a unique opportunity to not only achieve GV/m surface electric fields but also with relatively low THz pulse energies, since a single-cycle transform-limited waveform is the most efficient way to achieve intense electric fields. Here, electron bunches of 50 fC from a flat copper photocathode are accelerated from rest to tens of eV by a microjoule THz pulse with peak electric field of 72 MV/m at 1 kHz repetition rate. We show that scaling to the readily-available GV/m THz field regime would translate to monoenergetic electron beams of ~100 keV. PMID:26486697

  5. Note: O-ring stack system for electron gun alignment.

    PubMed

    Park, In-Yong; Cho, Boklae; Han, Cheolsu; Shin, Seungmin; Lee, Dongjun; Ahn, Sang Jung

    2015-01-01

    We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignment and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.

  6. Model for intensity calculation in electron guns

    NASA Astrophysics Data System (ADS)

    Doyen, O.; De Conto, J. M.; Garnier, J. P.; Lefort, M.; Richard, N.

    2007-04-01

    The calculation of the current in an electron gun structure is one of the main investigations involved in the electron gun physics understanding. In particular, various simulation codes exist but often present some important discrepancies with experiments. Moreover, those differences cannot be reduced because of the lack of physical information in these codes. We present a simple physical three-dimensional model, valid for all kinds of gun geometries. This model presents a better precision than all the other simulation codes and models encountered and allows the real understanding of the electron gun physics. It is based only on the calculation of the Laplace electric field at the cathode, the use of the classical Child-Langmuir's current density, and a geometrical correction to this law. Finally, the intensity versus voltage characteristic curve can be precisely described with only a few physical parameters. Indeed, we have showed that only the shape of the electric field at the cathode without beam, and a distance of an equivalent infinite planar diode gap, govern mainly the electron gun current generation.

  7. Note: O-ring stack system for electron gun alignment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, In-Yong; Cho, Boklae; Han, Cheolsu

    We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignmentmore » and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.« less

  8. Simulating Pressure Profiles for the Free-Electron Laser Photoemission Gun Using Molflow+

    NASA Astrophysics Data System (ADS)

    Song, Diego; Hernandez-Garcia, Carlos

    2012-10-01

    The Jefferson Lab Free Electron Laser (FEL) generates tunable laser light by passing a relativistic electron beam generated in a high-voltage DC electron gun with a semiconducting photocathode through a magnetic undulator. The electron gun is in stringent vacuum conditions in order to guarantee photocathode longevity. Considering an upgrade of the electron gun, this project consists of simulating pressure profiles to determine if the novel design meets the electron gun vacuum requirements. The method of simulation employs the software Molflow+, developed by R. Kersevan at the Organisation Europ'eene pour la Recherche Nucl'eaire (CERN), which uses the test-particle Monte Carlo method to simulate molecular flows in 3D structures. Pressure is obtained along specified chamber axes. Results are then compared to measured pressure values from the existing gun for validation. Outgassing rates, surface area, and pressure were found to be proportionally related. The simulations indicate that the upgrade gun vacuum chamber requires more pumping compared to its predecessor, while it holds similar vacuum conditions. The ability to simulate pressure profiles through tools like Molflow+, allows researchers to optimize vacuum systems during the engineering process.

  9. Electron guns and collectors developed at INP for electron cooling devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharapa, A.N.; Shemyakin, A.V.

    1997-09-01

    Institute of Nuclear Physics (INP) has a rich experience in designing electron guns and collectors for electron cooling devices. This paper is a review of the experience of several INP research groups in this field. Some results obtained at INP for systems without a guiding magnetic field are also discussed.

  10. Inverse photoelectron spectrometer with magnetically focused electron gun

    NASA Technical Reports Server (NTRS)

    Krainsky, Isay L.

    1991-01-01

    An inverse photoelectron spectrometer is described which is based on the design of a magnetically focused low energy electron gun. The magnetic lens extends its field over a relatively large segment of the electron trajectory, which could provide a better focusing effect on a high-current-density low-velocity electron beam, providing the magnetic field in the vicinity of the target is reduced sufficiently to preserve the collinearity of the beam. In order to prove the concept, ray tracing is conducted using the Herrmannsfeldt program for solving electron trajectories in electrostatic and magnetostatic focusing systems. The program allows the calculation of the angles of the electron trajectories with the z axis, at the target location. The results of the ray-tracing procedure conducted for this gun are discussed. Some of the advantages of the magnetic focusing are also discussed.

  11. Performance of a carbon nanotube field emission electron gun

    NASA Astrophysics Data System (ADS)

    Getty, Stephanie A.; King, Todd T.; Bis, Rachael A.; Jones, Hollis H.; Herrero, Federico; Lynch, Bernard A.; Roman, Patrick; Mahaffy, Paul

    2007-04-01

    A cold cathode field emission electron gun (e-gun) based on a patterned carbon nanotube (CNT) film has been fabricated for use in a miniaturized reflectron time-of-flight mass spectrometer (RTOF MS), with future applications in other charged particle spectrometers, and performance of the CNT e-gun has been evaluated. A thermionic electron gun has also been fabricated and evaluated in parallel and its performance is used as a benchmark in the evaluation of our CNT e-gun. Implications for future improvements and integration into the RTOF MS are discussed.

  12. Development program on a cold cathode electron gun

    NASA Technical Reports Server (NTRS)

    Spindt, C. A.

    1979-01-01

    A prototype electron gun with a field emitter cathode capable of producing 95 mA in a 1/4 mm diameter beam at 12 kV was produced. Achievement of this goal required supporting studies in cathode fabrication, cathode performance, gun design, cathode mounting and gun fabrication. A series of empirical investigations advanced fabrication technology: More stable emitters were produced and multiple cone failure caused by chain reaction discharges were reduced. The cathode is capable of producing well over 95 mA, but a substantial collector development effort was required to demonstrate emission levels in the 100 mA region. Space charge problems made these levels difficult to achieve. Recommendations are made for future process and materials investigation. Electron gun designs were modeled and tested. A pair of two-electrode gun structures were fabricated and tested; one gun was delivered to NASA. Cathodes were pretested up to 100 mA at SRI and delivered to NASA for test in the gun structure.

  13. Theoretical investigation of the microwave electron gun

    NASA Astrophysics Data System (ADS)

    Gao, J.

    1990-12-01

    In this article the microwave electron gun (rf gun) is investigated theoretically in a general way. After a brief review of the sources of emittance growth in a cavity, the optimization criteria are given and optimized electric field distributions on the axes of the cavities are found, from which cavities for a rf gun can be designed.

  14. Low-energy plasma-cathode electron gun with a perforated emission electrode

    NASA Astrophysics Data System (ADS)

    Burdovitsin, Victor; Kazakov, Andrey; Medovnik, Alexander; Oks, Efim; Tyunkov, Andrey

    2017-11-01

    We describe research of influence of the geometric parameters of perforated electrode on emission parameters of a plasma cathode electron gun generating continuous electron beams at gas pressure 5-6 Pa. It is shown, that the emission current increases with increasing the hole diameters and decreasing the thickness of the perforated emission electrode. Plasma-cathode gun with perforated electron can provide electron extraction with an efficiency of up to 72 %. It is shown, that the current-voltage characteristic of the electron gun with a perforated emission electrode differs from that of similar guns with fine mesh grid electrode. The plasma-cathode electron gun with perforated emission electrode is used for electron beam welding and sintering.

  15. Modeling electron beam parameters and plasma interface position in an anode plasma electron gun with hydrogen atmosphere

    NASA Astrophysics Data System (ADS)

    Krauze, A.; Virbulis, J.; Kravtsov, A.

    2018-05-01

    A beam glow discharge based electron gun can be applied as heater for silicon crystal growth systems in which silicon rods are pulled from melt. Impacts of high-energy charged particles cause wear and tear of the gun and generate an additional source of silicon contamination. A steady-state model for electron beam formation has been developed to model the electron gun and optimize its design. Description of the model and first simulation results are presented. It has been shown that the model can simulate dimensions of particle impact areas on the cathode and anode, but further improvements of the model are needed to correctly simulate electron trajectory distribution in the beam and the beam current dependence on the applied gas pressure.

  16. Plasma-anode electron gun

    NASA Astrophysics Data System (ADS)

    Santoru, Joseph; Schumacher, Robert W.; Gregoire, Daniel J.

    1994-11-01

    The plasma-anode electron gun (PAG) is an electron source in which the thermionic cathode is replaced with a cold, secondary-electron-emitting electrode. Electron emission is stimulated by bombarding the cathode with high-energy ions. Ions are injected into the high-voltage gap through a gridded structure from a plasma source (gas pressure less than or equal to 50 mTorr) that is embedded in the anode electrode. The gridded structure serves as both a cathode for the plasma discharge and as an anode for the PAG. The beam current is modulated at near ground potential by modulating the plasma source, eliminating the need for a high-voltage modulator system. During laboratory tests, the PAG has demonstrated square-wave, 17-microsecond-long beam pulses at 100 kV and 10 A, and it has operated stably at 70 kV and 2.5 A for 210 microsecond pulse lengths without gap closure.

  17. High-perveance W-band Sheet-beam Electron Gun Design

    DTIC Science & Technology

    2008-04-01

    APR 2008 2. REPORT TYPE 3. DATES COVERED 00-00-2008 to 00-00-2008 4. TITLE AND SUBTITLE High -perveance W- band Sheet-beam Electron Gun Design 5a...8-98) Prescribed by ANSI Std Z39-18 10.1: High -perveance W- band Sheet-beam Electron Gun Design Khanh T. Nguyen1, John Pasour, Edward L. Wright1...effects due to cathode temperature are also included in the simulation. Keywords: Sheet beam; W- band ; electron gun; high perveance; amplifiers

  18. Thermal analysis of electron gun for travelling wave tubes

    NASA Astrophysics Data System (ADS)

    Bhat, K. S.; Sreedevi, K.; Ravi, M.

    2006-11-01

    Thermal analysis of a pierce type electron gun using the FEM software ANSYS and its experimental validation are presented in this paper. Thermal analysis of the electron gun structure has been carried out to find out the effect of heater power on steady state temperature and warm-up time. The thermal drain of the supporting structure has also been analyzed for different materials. These results were experimentally verified in an electron gun. The experimental results closely match the ANSYS results.

  19. rf traveling-wave electron gun for photoinjectors

    NASA Astrophysics Data System (ADS)

    Schaer, Mattia; Citterio, Alessandro; Craievich, Paolo; Reiche, Sven; Stingelin, Lukas; Zennaro, Riccardo

    2016-07-01

    The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL) machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least) double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  20. A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kutsaev, Sergey; Agustsson, R.; Hartzell, J

    A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power testsmore » of the cathode assembly of the new gun.« less

  1. Compact Electron Gun Based on Secondary Emission Through Ionic Bombardment

    PubMed Central

    Diop, Babacar; Bonnet, Jean; Schmid, Thomas; Mohamed, Ajmal

    2011-01-01

    We present a new compact electron gun based on the secondary emission through ionic bombardment principle. The driving parameters to develop such a gun are to obtain a quite small electron gun for an in-flight instrument performing Electron Beam Fluorescence measurements (EBF) on board of a reentry vehicle in the upper atmosphere. These measurements are useful to characterize the gas flow around the vehicle in terms of gas chemical composition, temperatures and velocity of the flow which usually presents thermo-chemical non-equilibrium. Such an instrument can also be employed to characterize the upper atmosphere if placed on another carrier like a balloon. In ground facilities, it appears as a more practical tool to characterize flows in wind tunnel studies or as an alternative to complex electron guns in industrial processes requiring an electron beam. We describe in this paper the gun which has been developed as well as its different features which have been characterized in the laboratory. PMID:22163896

  2. Back-bombardment compensation in microwave thermionic electron guns

    NASA Astrophysics Data System (ADS)

    Kowalczyk, Jeremy M. D.; Madey, John M. J.

    2014-12-01

    The development of capable, reliable, and cost-effective compact electron beam sources remains a long-standing objective of the efforts to develop the accelerator systems needed for on-site research and industrial applications ranging from electron beam welding to high performance x-ray and gamma ray light sources for element-resolved microanalysis and national security. The need in these applications for simplicity, reliability, and low cost has emphasized solutions compatible with the use of the long established and commercially available pulsed microwave rf sources and L-, S- or X-band linear accelerators. Thermionic microwave electron guns have proven to be one successful approach to the development of the electron sources for these systems providing high macropulse average current beams with picosecond pulse lengths and good emittance out to macropulse lengths of 4-5 microseconds. But longer macropulse lengths are now needed for use in inverse-Compton x-ray sources and other emerging applications. We describe in this paper our approach to extending the usable macropulse current and pulse length of these guns through the use of thermal diffusion to compensate for the increase in cathode surface temperature due to back-bombardment.

  3. Finite element analyses of a linear-accelerator electron gun

    NASA Astrophysics Data System (ADS)

    Iqbal, M.; Wasy, A.; Islam, G. U.; Zhou, Z.

    2014-02-01

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

  4. Finite element analyses of a linear-accelerator electron gun.

    PubMed

    Iqbal, M; Wasy, A; Islam, G U; Zhou, Z

    2014-02-01

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

  5. Design and development of a 40 kV pierce electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharjee, D.; Tiwari, R.; Jayaprakash, D., E-mail: dhruva.bhattacharjee@gmail.com

    A 40 kV electron gun is designed and developed using the Pierce configuration for the focusing electrode. Simulations were carried out using CST Particle Studio. The Gun is a thermionic type electron gun with indirect heating of the LaB6 cathode. The gun is capable of delivering a beam current of more than 500 mA at 40 kV with a beam size of less than 5 mm. The cathode assembly consists of cups and heat shields made out of Tantalum and Rhenium sheets. The cathode assembly and the electron gun was fabricated, assembled and tested on test bench for cathode conditioning,more » HV conditioning and beam characterization. This paper presents the gun design, particle simulations study, testing of the gun on test bench. (author)« less

  6. Electron gun jitter effects on beam bunching

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, M. S.; Iqbal, M., E-mail: muniqbal.chep@pu.edu.pk; Centre for High Energy Physics, University of the Punjab, Lahore 45590

    For routine operation of Beijing Electron Positron Collider II (BEPCII) linac, many factors may affect the beam bunching process directly or indirectly. We present the measurements and analyses of the gun timing jitter, gun high voltage jitter, and beam energy at the exit of the standard acceleration section of the linac quantitatively. Almost 80 mV and more than 200 ps of gun high voltage and time jitters have ever been measured, respectively. It was analyzed that the gun timing jitter produced severe effects on beam energy than the gun high voltage jitter, if the timing jitter exceeded 100 ps whichmore » eventually deteriorates both the beam performance and the injection rate to the storage ring.« less

  7. Secondary emission electron gun using external primaries

    DOEpatents

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY

    2009-10-13

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  8. Secondary emission electron gun using external primaries

    DOEpatents

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY; Kewisch, Jorg [Wading River, NY; Chang, Xiangyun [Middle Island, NY

    2007-06-05

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  9. Fabrication of compact electron gun for 6 MeV X-ray source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghodke, S.R.; Barnwal, Rajesh; Kumar, Mahendra, E-mail: ghodke_barc@yahoo.co.in

    The 6 MeV X-Ray source for container cargo scanning application has been designed and developed by the Accelerator and Pulse Power Division, BARC, Mumbai. This compact linac has been designed as a mobile system, to be mounted on a moving container. In linac-based cargo-scanning system, to work electron gun on a movable container, it has to be robust. Electron gun is to work at 10{sup -7} mbar vacuum and 2000 degree Celsius temperature. An effort is made to engineer the gun assembly to make it more robust and aligned. The linac acts as the source of X-rays, which fall onmore » the cargo and are then detected by the detector system. Many components are indigenously developed like grid, insulating ring, Tungsten filament and filament guide, which are made from alumina ceramic and Tantalum which is to work at 1500 degree Celsius. Filament connector is made from Invar to reduce heat loss and to make rigid connection. It was CNC machined and wire cut by EDM. Invar and Copper electrode feed through is shrink fitted with the help of liquid Nitrogen. Shrink fit tolerances of 15 micrometer are achieved by jig boring machining processes. Tantalum cup for LaB6 cathode and heat shield are made from die and punch mechanism. For alignment of electron emitter with beam axis this Tantalum cup is a crucial component. Electron gun is assembled and aligned its components with the help of precision jigs. The whole assembly was Helium leak tested by MSLD up to 4 x 10{sup -10} mbar.l/s vacuum, no leak was found. This paper will describe the machining, Tantalum cup forming, ceramic components development, heat shields, ceramic feed through etc of electron gun. (author)« less

  10. A Robust High Current Density Electron Gun

    NASA Astrophysics Data System (ADS)

    Mako, F.; Peter, W.; Shiloh, J.; Len, L. K.

    1996-11-01

    Proof-of-principle experiments are proposed to validate a new concept for a robust, high-current density Pierce electron gun (RPG) for use in klystrons and high brightness electron sources for accelerators. This rugged, long-life electron gun avoids the difficulties associated with plasma cathodes, thermionic emitters, and field emission cathodes. The RPG concept employs the emission of secondary electrons in a transmission mode as opposed to the conventional mode of reflection, i.e., electrons exit from the back face of a thin negative electron affinity (NEA) material, and in the same direction as the incident beam. Current amplification through one stage of a NEA material could be over 50 times. The amplification is accomplished in one or more stages consisting of one primary emitter and one or more secondary emitters. The primary emitter is a low current density robust emitter (e.g., thoriated tungsten). The secondary emitters are thin NEA electrodes which emit secondary electrons in the same direction as the incident beam. Specific application is targeted for a klystron gun to be used by SLAC with a cold cathode at 30-40 amps/cm^2 output from the secondary emission stage, a ~2 μs pulse length, and ~200 pulses/second.

  11. A 120kV IGBT modulator for driving a pierce electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Earley, L. M.; Brown, R. W.; Carlson, R. L.

    2004-01-01

    An IGBT modulator has been developed to drive a 120 kV, 23 A Pierce electron gun. The modulator is capable of producing pulses up to 10 {mu}s in width at repetition rates up to 10Hz with no active reset. The pulse rise time on the electron gun will be approximately 2 {mu}s and the remaining 8 {mu}s of flattop is tuned to have a ripple of less than 1 percent rms. The modulator technology was developed from a previous 50 kV prototype. The modulator consists of six boards, each with one EUPEC IGBT that drives a single common step-up transformermore » wound on METGLAS 2605SC cores. The six transformer cores share a common bi-filar output secondary winding. The modulator uses a fiber optic trigger system and has a high voltage cable output with an epoxy receptacle on the oil end and a ceramic receptacle on the vacuum end. The 120 kV electron gun was manufactured by MDS Co. and will be used to generate sheet electron beams from the standard pencil beam produced by the Pierce electron gun.« less

  12. The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

    NASA Astrophysics Data System (ADS)

    Cornish, S.; Khachan, J.

    2016-02-01

    A new and simple type of electron gun is presented. Unlike conventional electron guns, which require a heated filament or extractor, accelerator and focusing electrodes, this gun uses the collimated electron microchannels of an inertial electrostatic confinement (IEC) discharge to achieve the same outcome. A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge. Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode. This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid. The internal operating pressure range of the gun is 35-190 mTorr. A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential. The chamber was operated at pressures of 4-12 mTorr. The measured current produced by the gun was 0.1-3 mA (0.2-14 mA corrected measurement) for discharge currents of 1-45 mA and discharge voltages of 0.5-12 kV. The collimated electron beam emerges from the aperture into the vacuum chamber. The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun. This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required.

  13. Investigation on the optimal magnetic field of a cusp electron gun for a W-band gyro-TWA

    NASA Astrophysics Data System (ADS)

    Zhang, Liang; He, Wenlong; Donaldson, Craig R.; Cross, Adrian W.

    2018-05-01

    High efficiency and broadband operation of a gyrotron traveling wave amplifier (gyro-TWA) require a high-quality electron beam with low-velocity spreads. The beam velocity spreads are mainly due to the differences of the electric and magnetic fields that the electrons withstand the electron gun. This paper investigates the possibility to decouple the design of electron gun geometry and the magnet system while still achieving optimal results, through a case study of designing a cusp electron gun for a W-band gyro-TWA. A global multiple-objective optimization routing was used to optimize the electron gun geometry for different predefined magnetic field profiles individually. Their results were compared and the properties of the required magnetic field profile are summarized.

  14. Low Emittance Guns for the ILC Polarized Electron Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressedmore » by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of {>=}200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while {>=}500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns.« less

  15. Low Emittance Guns for the ILC Polarized Electron Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressedmore » by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of {ge}200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while {ge}500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns.« less

  16. The Experimental Study of Novel Pseudospark Hollow Cathode Plasma Electron Gun

    NASA Astrophysics Data System (ADS)

    Gu, Xiaowei; Meng, Lin; Sun, Yiqin; Yu, Xinhua

    2008-11-01

    The high-power microwave devices with plasma-filled have unique properties. One of the major problems associated with plasma-filled microwave sources is that ions from the plasma drift toward the gun regions of the tube. This bombardment is particularly dangerous for the gun, where high-energy ion impacts can damage the cathode surface and degrade its electron emission capabilities. One of the techniques investigated to mitigate this issue is to replace the material cathode with plasma cathode. Now, we study the novel electron gun (E-gun) that can be suitable for high power microwave device applications, adopting two forms of discharge channel, 1: a single hole channel, the structure can produce a solid electron beam; 2: porous holes channel, the structure can generate multiple electronic injection which is similar to the annular electron beam.

  17. Note: Characteristic beam parameter for the line electron gun.

    PubMed

    Iqbal, M; Islam, G U; Zhou, Z; Chi, Y

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm(2) at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm(2)), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  18. Note: Characteristic beam parameter for the line electron gun

    NASA Astrophysics Data System (ADS)

    Iqbal, M.; Islam, G. U.; Zhou, Z.; Chi, Y.

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm2 at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm2), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  19. Finite element analyses of a linear-accelerator electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iqbal, M., E-mail: muniqbal.chep@pu.edu.pk, E-mail: muniqbal@ihep.ac.cn; Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049; Wasy, A.

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gunmore » is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.« less

  20. NASCAP simulation of laboratory charging tests using multiple electron guns

    NASA Technical Reports Server (NTRS)

    Mandell, M. J.; Katz, I.; Parks, D. E.

    1981-01-01

    NASCAP calculations have been performed simulating exposure of a spacecraft-like model to multiple electron guns. The results agree well with experiment. It is found that magnetic field effects are fairly small, but substantial differential charging can result from electron gun placement. Conditions for surface flashover are readily achieved.

  1. Note: Characteristic beam parameter for the line electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iqbal, M.; Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049; Islam, G. U.

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm{sup 2} at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm{sup 2}), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  2. Theory and simulation of backbombardment in single-cell thermionic-cathode electron guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edelen, J.  P.; Biedron, S.  G.; Harris, J.  R.

    This paper presents a comparison between simulation results and a first principles analytical model of electron back-bombardment developed at Colorado State University for single-cell, thermionic-cathode rf guns. While most previous work on back-bombardment has been specific to particular accelerator systems, this work is generalized to a wide variety of guns within the applicable parameter space. The merits and limits of the analytic model will be discussed. This paper identifies the three fundamental parameters that drive the back-bombardment process, and demonstrates relative accuracy in calculating the predicted back-bombardment power of a single-cell thermionic gun.

  3. Theory and simulation of backbombardment in single-cell thermionic-cathode electron guns

    DOE PAGES

    Edelen, J.  P.; Biedron, S.  G.; Harris, J.  R.; ...

    2015-04-01

    This paper presents a comparison between simulation results and a first principles analytical model of electron back-bombardment developed at Colorado State University for single-cell, thermionic-cathode rf guns. While most previous work on back-bombardment has been specific to particular accelerator systems, this work is generalized to a wide variety of guns within the applicable parameter space. The merits and limits of the analytic model will be discussed. This paper identifies the three fundamental parameters that drive the back-bombardment process, and demonstrates relative accuracy in calculating the predicted back-bombardment power of a single-cell thermionic gun.

  4. Profiling of back-scattered electrons in opposed magnetic field of a Twin Electron Beam Gun

    NASA Astrophysics Data System (ADS)

    Sethi, S.; Gupta, Anchal; Dileep Kumar, V.; Mukherjee, Jaya; Gantayet, L. M.

    2012-11-01

    Electron gun is extensively used in material processing, physical vapour deposition and atomic vapour based laser processes. In these processes where the electron beam is incident on the substrate, a significant fraction of electron beam gets back-scattered from the target surface. The trajectory of this back scattered electron beam depends on the magnetic field in the vicinity. The fraction of back-scattered depends on the atomic number of the target metal and can be as high as ~40% of the incident beam current. These back-scattered electrons can cause undesired hot spots and also affect the overall process. Hence, the study of the trajectory of these back-scattered electrons is important. This paper provides the details of experimentally mapped back-scattered electrons of a 2×20kW Twin Electron Beam Gun (TEBG) in opposed magnetic field i.e. with these guns placed at 180° to each other.

  5. An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

    NASA Astrophysics Data System (ADS)

    Schröder, Benjamin; Sivis, Murat; Bormann, Reiner; Schäfer, Sascha; Ropers, Claus

    2015-12-01

    We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

  6. An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schröder, Benjamin; Sivis, Murat; Bormann, Reiner

    We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

  7. Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source.

    PubMed

    Pikin, A; Beebe, E N; Raparia, D

    2013-03-01

    Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current up to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 ÷ 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 ÷ 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.

  8. Developments in electron gun simulation

    NASA Astrophysics Data System (ADS)

    Herrmannsfeldt, W. B.

    1997-01-01

    This paper will discuss the developments in the electron gun simulation programs that are based on EGUN and its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications on EGN2 of this evolution will be discussed. Some examples and a review of the capabilities of the EGUN family will be described.

  9. Electron gun using carbon-nanofiber field emitter.

    PubMed

    Sakai, Y; Haga, A; Sugita, S; Kita, S; Tanaka, S-I; Okuyama, F; Kobayashi, N

    2007-01-01

    An electron gun constructed using carbon-nanofiber (CNF) emitters and an electrostatic Einzel lens system has been characterized for the development of a high-resolution x-ray source. The CNFs used were grown on tungsten and palladium tips by plasma-enhanced chemical-vapor deposition. Electron beams with the energies of 10electron beam extracted from the CNFs was estimated to be D<50 microm in diameter. Superior performance was realized by using CNFs with larger fiber radii (100-500 nm) grown sparsely on the metal tips, which were installed in a holder at the short length L=0.5 mm.

  10. A cusp electron gun for millimeter wave gyrodevices

    NASA Astrophysics Data System (ADS)

    Donaldson, C. R.; He, W.; Cross, A. W.; Li, F.; Phelps, A. D. R.; Zhang, L.; Ronald, K.; Robertson, C. W.; Whyte, C. G.; Young, A. R.

    2010-04-01

    The experimental results of a thermionic cusp electron gun, to drive millimeter and submillimeter wave harmonic gyrodevices, are reported in this paper. Using a "smooth" magnetic field reversal formed by two coils this gun generated an annular-shaped, axis-encircling electron beam with 1.5 A current, and an adjustable velocity ratio α of up to 1.56 at a beam voltage of 40 kV. The beam cross-sectional shape and transported beam current were measured by a witness plate technique and Faraday cup, respectively. These measured results were found to be in excellent agreement with the simulated results using the three-dimensional code MAGIC.

  11. Solid-state pulse modulator using Marx generator for a medical linac electron-gun

    NASA Astrophysics Data System (ADS)

    Lim, Heuijin; Hyeok Jeong, Dong; Lee, Manwoo; Lee, Mujin; Yi, Jungyu; Yang, Kwangmo; Ro, Sung Chae

    2016-04-01

    A medical linac is used for the cancer treatment and consists of an accelerating column, waveguide components, a magnetron, an electron-gun, a pulse modulator, and an irradiation system. The pulse modulator based on hydrogen thyratron-switched pulse-forming network is commonly used in linac. As the improvement of the high power semiconductors in switching speed, voltage rating, and current rating, an insulated gate bipolar transistor has become the more popular device used for pulsed power systems. We propose a solid-state pulse modulator to generator high voltage by multi-stacked storage-switch stages based on the Marx generator. The advantage of our modulator comes from the use of two semiconductors to control charging and discharging of the storage capacitor at each stage and it allows to generate the pulse with various amplitudes, widths, and shapes. In addition, a gate driver for two semiconductors is designed to reduce the control channels and to protect the circuits. It is developed for providing the pulsed power to a medical linac electron-gun that requires 25 kV and 1 A as the first application. In order to improve the power efficiency and achieve the compactness modulator, a capacitor charging power supply, a Marx pulse generator, and an electron-gun heater isolated transformer are constructed and integrated. This technology is also being developed to extend the high power pulsed system with > 1 MW and also other applications such as a plasma immersed ion implantation and a micro pulse electrostatic precipitator which especially require variable pulse shape and high repetition rate > 1 kHz. The paper describes the design features and the construction of this solid-state pulse modulator. Also shown are the performance results into the linac electron-gun.

  12. Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, A.; Beebe, E. N.; Raparia, D.

    Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current upmore » to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 Division-Sign 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 Division-Sign 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.« less

  13. Beam Dynamics Simulation of Photocathode RF Electron Gun at the PBP-CMU Linac Laboratory

    NASA Astrophysics Data System (ADS)

    Buakor, K.; Rimjaem, S.

    2017-09-01

    Photocathode radio-frequency (RF) electron guns are widely used at many particle accelerator laboratories due to high quality of produced electron beams. By using a short-pulse laser to induce the photoemission process, the electrons are emitted with low energy spread. Moreover, the photocathode RF guns are not suffered from the electron back bombardment effect, which can cause the limited electron current and accelerated energy. In this research, we aim to develop the photocathode RF gun for the linac-based THz radiation source. Its design is based on the existing gun at the PBP-CMU Linac Laboratory. The gun consists of a one and a half cell S-band standing-wave RF cavities with a maximum electric field of about 60 MV/m at the centre of the full cell. We study the beam dynamics of electrons traveling through the electromagnetic field inside the RF gun by using the particle tracking program ASTRA. The laser properties i.e. transverse size and injecting phase are optimized to obtain low transverse emittance. In addition, the solenoid magnet is applied for beam focusing and emittance compensation. The proper solenoid magnetic field is then investigated to find the optimum value for proper emittance conservation condition.

  14. Design and construction of a DC high-brightness laser driven electron gun

    NASA Astrophysics Data System (ADS)

    Zhao, K.; Geng, R. L.; Wang, L. F.; Zhang, B. C.; Yu, J.; Wang, T.; Wu, G. F.; Song, J. H.; Chen, J. E.

    1996-02-01

    A DC high-brightness laser driven photoemissive electron gun is being developed at Peking University, in order to produce 50-100 ps electron bunches of high quality. The gun consists of a photocathode preparation chamber and a DC acceleration cavity. Different ways of fabricating photocathodes, such as chemical vapor deposition, ion beam implantation and ion beam enhanced deposition, can be adopted. The acceleration gap is designed with the aid of simulation codes EGUN and POISSON. The laser system is a mode-locked Nd-YAG oscillator proceeded by an amplifier at 10 Hz repetition rate, which can deliver three different wavelengths (1064/532/266 nm). The combination of a superconducting cavity with the photocathode preparation chamber is also discussed in this paper.

  15. Design and development of line type modulators for high impedance electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixit, Kavita P.; Tillu, Abhijit; Chavan, Ramchandra

    Conventional line type modulators are routinely used for powering pulsed power microwave devices such as magnetrons and klystrons used for radar, medical and scientific applications. The load impedance (operating point) is fairly well defined in these cases, and makes the design of the discharging circuit of the modulator straight forward. This paper describes the Line type modulators that have been developed and being routinely used for powering the Triode Electron Gun of industrial electron linacs. The beam parameters of such guns are user defined and the pulse current varies from few mA to 800mA (typ). The beam energies requirement variesmore » from 40 keV to 80 keV. Hence the impedance offered by the electron gun to the power source (modulator) is not well defined. The load capacitance which is inclusive of the various stray capacitances along with the intrinsic gun capacitance is ∼ 200-400 pF. This capacitance, which depends on the configuration, shunts the load and makes the effective load highly capacitive with the resistive part varying over a wide range. The paper describes the design and development of conventional line type modulators for powering Electron gun load of the type described above. (author)« less

  16. Development of a novel thermionic RF electron gun applied on a compact THz-FEL facility

    NASA Astrophysics Data System (ADS)

    Hu, T. N.; Pei, Y. J.; Qin, B.; Liu, K. F.; Feng, G. Y.

    2018-04-01

    The current requirements from civil and commercial applications lead to the development of compact free-electron laser (FEL)-based terahertz (THz) radiation sources. A picosecond electron gun plays an important role in an FEL-THz facility and attracts significant attention, as machine performance is very sensitive to initial conditions. A novel thermionic gun with an external cathode (EC) and two independently tunable cavities (ITCs) has been found to be a promising alternative to conventional electron sources due to its remarkable characteristics, and correspondingly an FEL injector can achieve a balance between a compact layout and high brightness benefitting from the velocity bunching properties and RF focusing effects in the EC-ITC gun. Nevertheless, the EC-ITC gun has not been extensively examined as part of the FEL injector in the past years. In this regard, to fill this gap, a development focusing on the experimental setup of an FEL injector based on an EC-ITC gun is described in detail. Before assembly, dynamic beam simulations were performed to investigate the optimal mounting position for the Linac associated with the focusing coils, and a suitable radio-frequency (RF) system was established based on a power coupling design and allocation. The testing bench proved to be fully functional through basic experiments using typical diagnostic approaches for estimating primary parameters. Associated with dynamic beam calculations, a performance evaluation for an EC-ITC gun was established while providing indirect testing results for an FEL injector.

  17. Generation of Low-Energy High-Current Electron Beams in Plasma-Anode Electron Guns

    NASA Astrophysics Data System (ADS)

    Ozur, G. E.; Proskurovsky, D. I.

    2018-01-01

    This paper is a review of studies on the generation of low-energy high-current electron beams in electron guns with a plasma anode and an explosive-emission cathode. The problems related to the initiation of explosive electron emission under plasma and the formation and transport of high-current electron beams in plasma-filled systems are discussed consecutively. Considerable attention is given to the nonstationary effects that occur in the space charge layers of plasma. Emphasis is also placed on the problem of providing a uniform energy density distribution over the beam cross section, which is of critical importance in using electron beams of this type for surface treatment of materials. Examples of facilities based on low-energy high-current electron beam sources are presented and their applications in materials science and practice are discussed.

  18. A pulsed electron gun for the Plane Wave Transformer Linac

    NASA Astrophysics Data System (ADS)

    Mahadevan, S.; Gandhi, M. L.; Nandedkar, R. V.

    2003-01-01

    A pulsed diode electron gun delivering 500 mA current at 40 kV is described. The gun geometry is optimized using the Electron Trajectory Program EGUN at higher scaling factors by choosing the closest converging starting surface. The effect of an annular gap between cathode and focusing electrode on beam behaviour is compensated by using a suitable focusing electrode. The estimated perveance is 0.065 μperv and the normalized emittance is within 5 π mm mrad. The variation in current density at the cathode has been limited to within 10% across the face of the cathode. Salient features of the pulsed power supply and an insight of its interconnection with the gun are presented. The current measured at the Faraday cup is in agreement with the designed perveance.

  19. Progress Toward a Gigawatt-Class Annular Beam Klystron with a Thermionic Electron Gun

    NASA Astrophysics Data System (ADS)

    Fazio, M.; Carlsten, B.; Farnham, J.; Habiger, K.; Haynes, W.; Myers, J.; Nelson, E.; Smith, J.; Arfin, B.; Haase, A.

    2002-08-01

    In an effort to reach the gigawatt power level in the microsecond pulse length regime Los Alamos, in collaboration with SLAC, is developing an annular beam klystron (ABK) with a thermionic electron gun. We hope to address the causes of pulse shortening in very high peak power tubes by building a "hard-vacuum" tube in the 10-10 Torr range with a thermionic electron gun producing a constant impedance electron-beam. The ABK has been designed to operate at 5 Hz pulse repetition frequency to allow for RF conditioning. The electron gun has a magnetron injection gun configuration and uses a dispenser cathode running at 1100 degC to produce a 4 kA electron beam at 800 kV. The cathode is designed to run in the temperature-limited mode to help maintain beam stability in the gun. The beam-stick consisting of the electron gun, an input cavity, an idler cavity, and drift tube, and the collector has been designed collaboratively, fabricated at SLAC, then shipped to Los Alamos for testing. On the test stand at Los Alamos a low voltage emission test was performed, but unfortunately as we prepared for high voltage testing a problem with the cathode heater was encountered that prevented the cathode from reaching a high enough temperature for electron emission. A post-mortem examination will be done shortly to determine the exact cause of the heater failure. The RF design has been proceeding and is almost complete. The output cavity presents a challenging design problem in trying to efficiently extract energy from the low impedance beam while maintaining a gap voltage low enough to avoid breakdown and a Q high enough to maintain mode purity. In the next iteration, the ABK will have a new cathode assembly installed along with the remainder of the RF circuit. This paper will discuss the electron gun and the design of the RF circuit along with a report on the status of the work.

  20. Development program on a Spindt cold-cathode electron gun

    NASA Technical Reports Server (NTRS)

    Spindt, C. A.

    1982-01-01

    A thin film field emission cathode (TFFEC) array and a cold cathode electron gun based on the emitter were developed. A microwave tube gun that uses the thin film field emission cathode as an electron source is produced. State-of-the-art cathodes were fabricated and tested. The tip-packing density of the arrays were increased thereby increasing the cathode's current density capability. The TFFEC is based on the well known field emission effect and was conceived to exploit the advantages of that phenomenon while minimizing the difficulties associated with conventional field emission structures, e.g. limited life and high voltage requirements. Field emission follows the Fowler-Nordheim equation.

  1. A compact electron gun for time-resolved electron diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, Matthew S.; Lane, Paul D.; Wann, Derek A., E-mail: derek.wann@york.ac.uk

    A novel compact time-resolved electron diffractometer has been built with the primary goal of studying the ultrafast molecular dynamics of photoexcited gas-phase molecules. Here, we discuss the design of the electron gun, which is triggered by a Ti:Sapphire laser, before detailing a series of calibration experiments relating to the electron-beam properties. As a further test of the apparatus, initial diffraction patterns have been collected for thin, polycrystalline platinum samples, which have been shown to match theoretical patterns. The data collected demonstrate the focusing effects of the magnetic lens on the electron beam, and how this relates to the spatial resolutionmore » of the diffraction pattern.« less

  2. Electron emission and plasma generation in a modulator electron gun using ferroelectric cathode

    NASA Astrophysics Data System (ADS)

    Chen, Shutao; Zheng, Shuxin; Zhu, Ziqiu; Dong, Xianlin; Tang, Chuanxiang

    2006-10-01

    Strong electron emission and dense plasma generation have been observed in a modulator electron gun with a Ba 0.67Sr 0.33TiO 3 ferroelectric cathode. Parameter of the modulator electron gun and lifetime of the ferroelectric cathode were investigated. It was shown that electron emission from Ba 0.67Sr 0.33TiO 3 cathode with a positive triggering pulse is a sort of plasma emission. Electrons were emitted by the co-effect of surface plasma and non-compensated negative polarization charges at the surface of the ferroelectric. The element analyses of the graphite collector after emission process was performed to show the ingredient of the plasma consist of Ba, Ti and Cu heavy cations of the ceramic compound and electrode. It was demonstrated the validity of the Child-Langmuir law by introducing the decrease of vacuum gap and increase of emission area caused by the expansion of the surface plasma.

  3. Quantum efficiency temporal response and lifetime of a GaAs cathode in SRF electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.

    2010-05-23

    RF electron guns with a strained super lattice GaAs cathode can generate polarized electron beam of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface. In a normal conducting RF gun, the extremely high vaccum required by these cathodes can not be met. We report on an experiment with a superconducting SRF gun, which can maintain a vacuum of nearly 10-12 torr because of cryo-pumping at the temperature of 4.2K. With conventional activation, we obtained a QE of 3% at 532 nm, with lifetime of nearly 3 days in themore » preparation chamber. We plan to use this cathode in a 1.3 GHz 1/2 cell SRF gun to study its performance. In addition, we studied the multipacting at the location of cathode. A new model based on the Forkker-Planck equation which can estimate the bunch length of the electron beam is discussed in this paper. Future particle accelerators such as eRHIC and ILC require high brightness, high current polarized electrons Recently, using a superlattice crystal, the maximum polarization of 95% was reached. Activation with Cs,O lowers the electron affinity and makes it energetically possible for all the electrons excited in to the conduction band and reach the surface to escape into the vacuum. Presently the polarized electron sources are based on DC gun, such as that at the CEBAF at Jlab. In these devices, the life time of the cathode is extended due to the reduced back bombardment in their UHV conditions. However, the low accelerating gradient of the DC guns lead to poor longitudinal emittance. The higher accelerating gradient of the RF gun generates low emittance beams. Superconducting RF guns combine the excellent vacuum conditions of the DC guns with the higher accelerating gradients of the RF guns and provide potentially a long lived cathode with very low transverse and longitudinal emittance. In our work at BNL, we successfully activated the GaAs. The quantum efficient is 3% at 532 nm and is

  4. Development of a high power electron beam welding gun with replaceable high voltage feed-through insulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saha, T.K; Mascarenhas, M.; Kandaswamy, E., E-mail: tanmay@barc.gov.in

    Ceramic to metal sealed feed-through insulators are commonly used in electron beam welding gun. The above feed-through insulators are susceptible to failure, as the brazing joints in them are not always very strong. Failure in one of these feed-through could render the complete gun unusable. This problem has already been faced in BARC, which led to the development of the electron gun with replaceable feed through insulators. A 24 kW Electron Beam Welding (EBW) gun with indigenous designed replaceable insulators is fabricated in BARC. Emphasis during the design of the gun had been to reduce the use of imported componentsmore » to zero. This paper describes the design and fabrication of this gun and reports various simulations and tests performed. Beam trajectory of the gun is numerically computed and presented. Weld passes were carried out on stainless steel plates show satisfactory penetrations. (author)« less

  5. A compact high current pulsed electron gun with subnanosecond electron pulse widths

    NASA Technical Reports Server (NTRS)

    Khakoo, M. A.; Srivastava, S. K.

    1984-01-01

    A magnetically-collimated, double-pulsed electron gun capable of generating electron pulses with a peak instantaneous current of approximately 70 microamps and a temporal width of 0.35 ns (FWHM) has been developed. Calibration is accomplished by measuring the lifetime of the well known 2(1P)-to-1(1S) transition in helium (58.4nm) at a near-threshold electron-impact energy by use of the delayed-coincidence technique.

  6. Design of spherical electron gun for ultra high frequency, CW power inductive output tube

    NASA Astrophysics Data System (ADS)

    Kaushik, Meenu; Joshi, L. M.

    2016-03-01

    Inductive Output Tube (IOT) is an amplifier that usually operates in UHF range. It is an electron tube whose basic structure is similar to conventional vacuum devices. This device is widely used in broadcast applications but is now being explored for scientific applications also specifically, particle accelerators and fusion plasma heating purposes. The paper describes the design approach of a spherical gridded electron gun of a 500 MHz, 100 kW CW power IOT. The electron gun structure has been simulated and optimized for operating voltage and current of 40kV and 3.5 A respectively. The electromagnetic analysis of this spherical electron gun has been carried out in CST and TRAK codes.

  7. Accurate electron gun-positioning mechanism for electron beam-mapping of large cross-section magnetic surfaces

    NASA Astrophysics Data System (ADS)

    Anderson, F. S. B.; Middleton, F.; Colchin, R. J.; Million, D.

    1989-04-01

    A method of accurately supporting and positioning an electron source inside a large cross-sectional area magnetic field which provides very low electron beam occlusion is reported. The application of electrical discharge machining to the fabrication of a 1-m truss support structure has provided an extremely long, rigid and mechanically strong electron gun support. Reproducible electron gun positioning to within 1 mm has been achieved at any location within a 1×0.6-m2 area. The extremely thin sections of the support truss (≤1.5 mm) have kept the electron beam occlusion to less than 3 mm. The support and drive mechanism have been designed and fabricated at the University of Wisconsin for application to the mapping of the magnetic surface structure of the Advanced Toroidal Facility torsatron1 at the Oak Ridge National Laboratory.

  8. Electron bunch structure in energy recovery linac with high-voltage dc photoelectron gun

    NASA Astrophysics Data System (ADS)

    Saveliev, Y. M.; Jackson, F.; Jones, J. K.; McKenzie, J. W.

    2016-09-01

    The internal structure of electron bunches generated in an injector line with a dc photoelectron gun is investigated. Experiments were conducted on the ALICE (accelerators and lasers in combined experiments) energy recovery linac at Daresbury Laboratory. At a relatively low dc gun voltage of 230 kV, the bunch normally consisted of two beamlets with different electron energies, as well as transverse and longitudinal characteristics. The beamlets are formed at the head and the tail of the bunch. At a higher gun voltage of 325 kV, the beam substructure is much less pronounced and could be observed only at nonoptimal injector settings. Experiments and computer simulations demonstrated that the bunch structure develops during the initial beam acceleration in the superconducting rf booster cavity and can be alleviated either by increasing the gun voltage to the highest possible level or by controlling the beam acceleration from the gun voltage in the first accelerating structure.

  9. Design of indirectly heated thoriated tungsten cathode based strip electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maiti, Namita; Thakur, K.B.; Patil, D.S.

    Design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270 degree bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten. The solid cathode design has been suitably done to achieve required electron beam cross section. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to reduce the non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments shows that the modified design achieves one tomore » one correspondence of the solid cathode length and the electron beam length. (author)« less

  10. The design of an electron gun switchable between immersed and Brillouin flowa)

    NASA Astrophysics Data System (ADS)

    Becker, R.; Kester, O.

    2012-02-01

    An electron gun, which can be switched from immersed flow to Brillouin flow during operation, may have advantages for charge breeders as well as for electron beam ion sources and traps (EBISTs). For EBISTs this allows to change the current density according to the repetition frequency and charge state, for charge breeders and EBISTs a lower current density in immersed flow provides higher acceptance for injected ions, while the higher current density in Brillouin flow results in shorter breeding times and a lower emittance for the extracted beam. Therefore, we have designed such a gun for an EBIS with 5 T central magnetic field and without the use of iron and moving the gun. The gun was placed in the axial fringing field of the 5 T solenoid in such a position that a gate valve can be placed between the gun and the cryostat to allow for simple maintenance. The field at the cathode surface turned out to be only 0.05 T, which is not enough to focus 50 A/cm2 at a few kV. However, if a small normal conducting solenoid is placed over the vacuum tube in position of the gun, a field of 0.1 T may be obtained. With this the use of LaB6 as cathode material results in a magnetic compression of 44 and therewith in a focused current density in the trap region of more than 2000 A/cm2. By reversing the current in the gun solenoid the cathode field can easily compensated to zero. By proper design of the electrodes and the compression region, the gun will be able to deliver a beam in Brillouin flow. While this is interesting by itself - remember the "super-compression" reported on CRYEBIS-I - any magnetic field between zero and the value for immersed flow will result in an electron beam with a wide range of adjustable high current densities. The design tools used have been INTMAG(C) for the calculation of magnetic fields, EGN2(C) for the simulation of the gun and ANALYSE(C) for detailed analysis of the results (for more information see www.egun-igun.com).

  11. The design of an electron gun switchable between immersed and Brillouin flow.

    PubMed

    Becker, R; Kester, O

    2012-02-01

    An electron gun, which can be switched from immersed flow to Brillouin flow during operation, may have advantages for charge breeders as well as for electron beam ion sources and traps (EBISTs). For EBISTs this allows to change the current density according to the repetition frequency and charge state, for charge breeders and EBISTs a lower current density in immersed flow provides higher acceptance for injected ions, while the higher current density in Brillouin flow results in shorter breeding times and a lower emittance for the extracted beam. Therefore, we have designed such a gun for an EBIS with 5 T central magnetic field and without the use of iron and moving the gun. The gun was placed in the axial fringing field of the 5 T solenoid in such a position that a gate valve can be placed between the gun and the cryostat to allow for simple maintenance. The field at the cathode surface turned out to be only 0.05 T, which is not enough to focus 50 A∕cm(2) at a few kV. However, if a small normal conducting solenoid is placed over the vacuum tube in position of the gun, a field of 0.1 T may be obtained. With this the use of LaB(6) as cathode material results in a magnetic compression of 44 and therewith in a focused current density in the trap region of more than 2000 A∕cm(2). By reversing the current in the gun solenoid the cathode field can easily compensated to zero. By proper design of the electrodes and the compression region, the gun will be able to deliver a beam in Brillouin flow. While this is interesting by itself--remember the "super-compression" reported on CRYEBIS-I--any magnetic field between zero and the value for immersed flow will result in an electron beam with a wide range of adjustable high current densities. The design tools used have been INTMAG(C) for the calculation of magnetic fields, EGN2(C) for the simulation of the gun and ANALYSE(C) for detailed analysis of the results (for more information see www.egun-igun.com).

  12. Note: design and development of improved indirectly heated cathode based strip electron gun.

    PubMed

    Maiti, Namita; Bade, Abhijeet; Tembhare, G U; Patil, D S; Dasgupta, K

    2015-02-01

    An improved design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten, which acts as an improved source of electron at lower temperature. So, high power operation is possible without affecting structural integrity of the electron gun. The design issues are addressed based on the uniformity of temperature on the solid cathode and the single long filament based design. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to tailor the non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments have been carried out and it is seen that the modified design achieves one to one correspondence of the solid cathode length and the electron beam length.

  13. Note: Design and development of improved indirectly heated cathode based strip electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maiti, Namita; Patil, D. S.; Dasgupta, K.

    An improved design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten, which acts as an improved source of electron at lower temperature. So, high power operation is possible without affecting structural integrity of the electron gun. The design issues are addressed based on the uniformity of temperature on the solid cathode and the single long filament based design. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to tailor themore » non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments have been carried out and it is seen that the modified design achieves one to one correspondence of the solid cathode length and the electron beam length.« less

  14. Low-cost electron-gun pulser for table-top maser experiments

    NASA Astrophysics Data System (ADS)

    Grinberg, V.; Jerby, E.; Shahadi, A.

    1995-04-01

    A simple 10 kV electron-gun pulser for small-scale maser experiments is presented. This low-cost pulser has operated successfully in various table-top cyclotron-resonance maser (CRM) and free-electron maser (FEM) experiments. It consists of a low-voltage capacitor bank, an SCR control circuit and a transformer bank (car ignition coils) connected directly to the e-gun. The pulser produces a current of 3 A at 10 kV voltage in a Gaussian like shape of 1 ms pulse width. The voltage sweep during the pulse provides a useful tool to locate resonances of CRM and FEM interactions. Analytical expressions for the pulser design and experimental measurements are presented.

  15. An ultrafast electron microscope gun driven by two-photon photoemission from a nanotip cathode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bormann, Reiner; Strauch, Stefanie; Schäfer, Sascha, E-mail: schaefer@ph4.physik.uni-goettingen.de

    We experimentally and numerically investigate the performance of an advanced ultrafast electron source, based on two-photon photoemission from a tungsten needle cathode incorporated in an electron microscope gun geometry. Emission properties are characterized as a function of the electrostatic gun settings, and operating conditions leading to laser-triggered electron beams of very low emittance (below 20 nm mrad) are identified. The results highlight the excellent suitability of optically driven nano-cathodes for the further development of ultrafast transmission electron microscopy.

  16. Performance of an electron gun for a high-brightness X-ray generator.

    PubMed

    Sugimura, Takashi; Ohsawa, Satoshi; Ikeda, Mitsuo

    2008-05-01

    A prototype thermionic electron gun for a high-brightness X-ray generator has been developed. Its extraction voltage and design current are 60 kV and 100 mA (DC), respectively. The X-ray generator aims towards a maximum brilliance of 60 kW mm(-2). The beam sizes at the rotating anticathode must therefore be within 1.0 mm x 0.1 mm and a small beam emittance is required. The fabricated electron gun optimizes an aperture grid and a Whenelt electrode. The performance of the prototype electron gun measured using pulsed-beam tests is as follows: maximum beam current, 85.7 mA; beam focus size at the rotating anticathode, 0.79 mm x 0.13 mm. In DC beam tests, FWHM beam sizes were measured to be 0.65 mm x 0.08 mm at the rotating anticathode with a beam current of 45 mA. The beam current recently reached approximately 60 mA with some thermal problems.

  17. Electron beam gun with kinematic coupling for high power RF vacuum devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borchard, Philipp

    An electron beam gun for a high power RF vacuum device has components joined by a fixed kinematic coupling to provide both precise alignment and high voltage electrical insulation of the components. The kinematic coupling has high strength ceramic elements directly bonded to one or more non-ductile rigid metal components using a high temperature active metal brazing alloy. The ceramic elements have a convex surface that mates with concave grooves in another one of the components. The kinematic coupling, for example, may join a cathode assembly and/or a beam shaping focus electrode to a gun stem, which is preferably composedmore » of ceramic. The electron beam gun may be part of a high power RF vacuum device such as, for example, a gyrotron, klystron, or magnetron.« less

  18. High Impulse Gun Airborne Demonstration. GAU-13/A Weapon, Feed System, Gun Drive and Electronic Controls.

    DTIC Science & Technology

    1981-05-01

    made to provide mounting bosses for the closed loop conveyor chute . Ten small round bosses were welded onto the housing to provide this support...became necessary to depart from previous closed loop feeder designs . The original feed system consisted of a series of conveyor elements in a flexible...The flexible chuting has been replaced with rigid chuting forming a loop around the gun housing. This design affords the maximum stiffness and hence

  19. Thermocathode radio-frequency gun for the Budker Institute of Nuclear Physics free-electron laser

    NASA Astrophysics Data System (ADS)

    Volkov, V.; Getmanov, Ya.; Kenjebulatov, E.; Kolobanov, E.; Krutikhin, S.; Kurkin, G.; Ovchar, V.; Petrov, V. M.; Sedlyarov, I.

    2016-12-01

    A radio-frequency (RF) gun for a race-track microtron-recuperator injector driving the free-electron laser (FEL) (Budker Institute of Nuclear Physics) is being tested at a special stand. Electron bunches of the RF gun have an energy of up to 300 keV and a repetition rate of up to 90 MHz. The average electro-beam current can reach 100 mA in the continuous operation regime. The advantages of the new injector are as follows: long lifetime of the cathode for high average beam current; simple scheme of longitudinal beam bunching, which does not require an additional bunching resonator in the injector; absence of dark-current contamination of the injector beam; and comfortable RF gun operation due to the absence of a high potential of 300 kV at the cathode control circuits. In this study we describe the RF gun design, present the main characteristics of the injector with the RF gun, and give the results of testing.

  20. High-voltage testing of a 500-kV dc photocathode electron gun.

    PubMed

    Nagai, Ryoji; Hajima, Ryoichi; Nishimori, Nobuyuki; Muto, Toshiya; Yamamoto, Masahiro; Honda, Yosuke; Miyajima, Tsukasa; Iijima, Hokuto; Kuriki, Masao; Kuwahara, Makoto; Okumi, Shoji; Nakanishi, Tsutomu

    2010-03-01

    A high-voltage dc photocathode electron gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The dc photocathode electron gun is designed for future light sources based on energy-recovery linac and consists of a Cockcroft-Walton generator, a segmented cylindrical ceramic insulator, guard-ring electrodes, a support-rod electrode, a vacuum chamber, and a pressurized insulating gas tank. The segmented cylindrical ceramic insulator and the guard-ring electrodes were utilized to prevent any damage to the insulator from electrons emitted by the support-rod electrode.

  1. Advanced Laser Technologies for High-brightness Photocathode Electron Gun

    NASA Astrophysics Data System (ADS)

    Tomizawa, Hiromitsu

    A laser-excited photocathode RF gun is one of the most reliable high-brightness electron beam sources for XFELs. Several 3D laser shaping methods have been developed as ideal photocathode illumination sources at SPring-8 since 2001. To suppress the emittance growth caused by nonlinear space-charge forces, the 3D cylindrical UV-pulse was optimized spatially as a flattop and temporally as squarely stacked chirped pulses. This shaping system is a serial combination of a deformable mirror that adaptively shapes the spatial profile with a genetic algorithm and a UV-pulse stacker that consists of four birefringent α-BBO crystal rods for temporal shaping. Using this 3D-shaped pulse, a normalized emittance of 1.4 π mm mrad was obtained in 2006. Utilizing laser's Z-polarization, Schottky-effect-gated photocathode gun was proposed in 2006. The cathode work functions are reduced by a laser-induced Schottky effect. As a result of focusing a radially polarized laser pulse with a hollow lens in vacuum, the Z-field (Z-polarization) is generated at the cathode.

  2. Self aligning electron beam gun having enhanced thermal and mechanical stability

    DOEpatents

    Scarpetti, Jr., Raymond D.; Parkison, Clarence D.; Switzer, Vernon A.; Lee, Young J.; Sawyer, William C.

    1995-01-01

    A compact, high power electron gun having enhanced thermal and mechanical stability which incorporates a mechanically coupled, self aligning structure for the anode and cathode. The enhanced stability, and reduced need for realignment of the cathode to the anode and downstream optics during operation are achieved by use of a common support structure for the cathode and anode which requires no adjustment screws or spacers. The electron gun of the present invention also incorporates a modular design for the cathode, in which the electron emitter, its support structure, and the hardware required to attach the emitter assembly to the rest of the gun are a single element. This modular design makes replacement of the emitter simpler and requires no realignment after a new emitter has been installed. Compactness and a reduction in the possibility of high voltage breakdown are achieved by shielding the "triple point" where the electrode, insulator, and vacuum meet. The use of electric discharge machining (EDM) for fabricating the emitter allows for the accurate machining of the emitter into intricate shapes without encountering the normal stresses developed by standard emitter fabrication techniques.

  3. Self aligning electron beam gun having enhanced thermal and mechanical stability

    DOEpatents

    Scarpetti, R.D. Jr.; Parkison, C.D.; Switzer, V.A.; Lee, Y.J.; Sawyer, W.C.

    1995-05-16

    A compact, high power electron gun is disclosed having enhanced thermal and mechanical stability which incorporates a mechanically coupled, self aligning structure for the anode and cathode. The enhanced stability, and reduced need for realignment of the cathode to the anode and downstream optics during operation are achieved by use of a common support structure for the cathode and anode which requires no adjustment screws or spacers. The electron gun of the present invention also incorporates a modular design for the cathode, in which the electron emitter, its support structure, and the hardware required to attach the emitter assembly to the rest of the gun are a single element. This modular design makes replacement of the emitter simpler and requires no realignment after a new emitter has been installed. Compactness and a reduction in the possibility of high voltage breakdown are achieved by shielding the ``triple point`` where the electrode, insulator, and vacuum meet. The use of electric discharge machining (EDM) for fabricating the emitter allows for the accurate machining of the emitter into intricate shapes without encountering the normal stresses developed by standard emitter fabrication techniques. 12 Figs.

  4. Optimization of a triode-type cusp electron gun for a W-band gyro-TWA

    NASA Astrophysics Data System (ADS)

    Zhang, Liang; Donaldson, Craig R.; He, Wenlong

    2018-04-01

    A triode-type cusp electron gun was optimized through numerical simulations for a W-band gyrotron traveling wave amplifier. An additional electrode in front of the cathode could switch the electron beam on and off instantly when its electric potential is properly biased. An optimal electron beam of current 1.7 A and a velocity ratio (alpha) of 1.12 with an alpha spread of ˜10.7% was achieved when the triode gun was operated at 40 kV.

  5. Performance of an electron gun for a high-brightness X-ray generator

    PubMed Central

    Sugimura, Takashi; Ohsawa, Satoshi; Ikeda, Mitsuo

    2008-01-01

    A prototype thermionic electron gun for a high-brightness X-ray generator has been developed. Its extraction voltage and design current are 60 kV and 100 mA (DC), respectively. The X-ray generator aims towards a maximum brilliance of 60 kW mm−2. The beam sizes at the rotating anticathode must therefore be within 1.0 mm × 0.1 mm and a small beam emittance is required. The fabricated electron gun optimizes an aperture grid and a Whenelt electrode. The performance of the prototype electron gun measured using pulsed-beam tests is as follows: maximum beam current, 85.7 mA; beam focus size at the rotating anticathode, 0.79 mm × 0.13 mm. In DC beam tests, FWHM beam sizes were measured to be 0.65 mm × 0.08 mm at the rotating anticathode with a beam current of 45 mA. The beam current recently reached ∼60 mA with some thermal problems. PMID:18421153

  6. Cerenkov Radiator Driven by a Superconducting RF Electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poole, B R; Harris, J R

    2011-03-07

    The Naval Postgraduate School (NPS), Niowave, Inc., and Boeing have recently demonstrated operation of the first superconducting RF electron gun based on a quarter wave resonator structure. In preliminary tests, this gun has produced 10 ps long bunches with charge in excess of 78 pC, and with beam energy up to 396 keV. Initial testing occurred at Niowave's Lansing, MI facility, but the gun and diagnostic beam line are planned for installation in California in the near future. The design of the diagnostic beam line is conducive to the addition of a Cerenkov radiator without interfering with other beam linemore » operations. Design and simulations of a Cerenkov radiator, consisting of a dielectric lined waveguide will be presented. The dispersion relation for the structure is determined and the beam interaction is studied using numerical simulations. The characteristics of the microwave radiation produced in both the short and long bunch regimes will be presented.« less

  7. Note: Simulation and test of a strip source electron gun.

    PubMed

    Iqbal, Munawar; Islam, G U; Misbah, I; Iqbal, O; Zhou, Z

    2014-06-01

    We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm(2), respectively, that corresponds to power density of 11.5 kW/cm(2), at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive. Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.

  8. Study of beam transverse properties of a thermionic electron gun for application to a compact THz free electron laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Tongning, E-mail: TongningHu@hust.edu.cn, E-mail: yjpei@ustc.edu.cn; Qin, Bin; Tan, Ping

    A novel thermionic electron gun adopted for use in a high power THz free electron laser (FEL) is proposed in this paper. By optimization of the structural and radiofrequency (RF) parameters, the physical design of the gun is performed using dynamic calculations. Velocity bunching is used to minimize the bunch's energy spread, and the dynamic calculation results indicate that high quality beams can be provided. The transverse properties of the beams generated by the gun are also analyzed. The novel RF focusing effects of the resonance cavity are investigated precisely and are used to establish emittance compensation, which enables themore » injector length to be reduced. In addition, the causes of the extrema of the beam radius and the normalized transverse emittance are analyzed and interpreted, respectively, and slice simulations are performed to illustrate how the RF focusing varies along the bunch length and to determine the effects of that variation on the emittance compensation. Finally, by observation of the variations of the beam properties in the drift tube behind the electron gun, prospective assembly scenarios for the complete THz-FEL injector are discussed, and a joint-debugging process for the injector is implemented.« less

  9. Investigations and Applications of Field- and Photo-emitted Electron Beams from a Radio Frequency Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panuganti, SriHarsha

    Production of quality electron bunches using e cient ways of generation is a crucial aspect of accelerator technology. Radio frequency electron guns are widely used to generate and rapidly accelerate electron beams to relativistic energies. In the current work, we primarily study the charge generation processes of photoemission and eld emission inside an RF gun installed at Fermilab's High Brightness Electron Source Laboratory (HBESL). Speci cally, we study and characterize second-order nonlinear photoemission from a Cesium Telluride (Cs 2Te) semiconductor photocathode, and eld emission from carbon based cathodes including diamond eld emission array (DFEA) and carbon nanotube (CNT) cathodes locatedmore » in the RF gun's cavity. Finally, we discuss the application experiments conducted at the facility to produce soft x-rays via inverse Compton scattering (ICS), and to generate uniformly lled ellipsoidal bunches and temporally shaped electron beams from the Cs 2Te photocathode.« less

  10. Survey of SRF guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belomestnykh, S.

    Developing Superconducting RF (SRF) electron guns is an active field with several laboratories working on different gun designs. While the first guns were based on elliptic cavity geometries, Quarter Wave Resonator (QWR) option is gaining popularity. QWRs are especially well suited for producing beams with high charge per bunch. In this talk we will describe recent progress in developing both types of SRF guns. SRF guns made excellent progress in the last two years. Several guns generated beams and one, at HZDR, injected beam into an accelerator. By accomplishing this, HZDR/ELBE gun demonstrated feasibility of the SRF gun concept withmore » a normal-conducting Cs{sub 2}Te cathode. The cathode demonstrated very good performance with the lifetime of {approx}1 year. However, for high average current/high bunch charge operation CsK{sub 2}Sb is preferred as it needs green lasers, unlike UV laser for the Cs{sub 2}Te, which makes it easier to build laser/optics systems. Other high QE photocathodes are being developed for SRF guns, most notably diamond-amplified photocathode. Several QWR guns are under development with one producing beam already. They are very promising for high bunch charge operation. The field is very active and we should expect more good results soon.« less

  11. High voltage threshold for stable operation in a dc electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Masahiro, E-mail: masahiro@post.kek.jp; Nishimori, Nobuyuki, E-mail: n-nishim@tagen.tohoku.ac.jp

    We report clear observation of a high voltage (HV) threshold for stable operation in a dc electron gun. The HV hold-off time without any discharge is longer than many hours for operation below the threshold, while it is roughly 10 min above the threshold. The HV threshold corresponds to the minimum voltage where discharge ceases. The threshold increases with the number of discharges during HV conditioning of the gun. Above the threshold, the amount of gas desorption per discharge increases linearly with the voltage difference from the threshold. The present experimental observations can be explained by an avalanche discharge modelmore » based on the interplay between electron stimulated desorption (ESD) from the anode surface and subsequent secondary electron emission from the cathode by the impact of ionic components of the ESD molecules or atoms.« less

  12. Developments in the electron gun simulation program, EGUN

    NASA Astrophysics Data System (ADS)

    Herrmannsfeldt, W. B.

    1994-11-01

    This paper discusses the developments in the electron gun simulation programs that are based on EGUN with its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications of this evolution on EGN2 are discussed. Some examples and a review of the capabilities of the EGUN family are described.

  13. Developments in the electron gun simulation program, EGUN

    NASA Astrophysics Data System (ADS)

    Herrmannsfeldt, W. B.

    1995-07-01

    This paper discusses the developments in the electron gun simulation programs that are based on EGUN with its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications of this evolution on EGN2 are discussed. Some examples and a review of the capabilities of the EGUN family are described.

  14. Use of vacuum arc plasma guns for a metal puff Z-pinch system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rousskikh, A. G.; Zhigalin, A. S.; Oreshkin, V. I.

    The performance of a metal puff Z-pinch system has been studied experimentally. In this type of system, the initial cylindrical shell 4 cm in diameter was produced by ten plasma guns. Each gun initiates a vacuum arc operating between magnesium electrodes. The net current of the guns was 80 kA. The arc-produced plasma shell was compressed by using a 450-kA, 450-ns driver, and as a result, a plasma column 0.3 cm in diameter was formed. The electron temperature of the plasma reached 400 eV at an average ion concentration of 1.85 {center_dot} 10{sup 18} cm{sup -3}. The power of themore » Mg K-line radiation emitted by the plasma for 15-30 ns was 300 MW/cm.« less

  15. Simulated Performance of the Wisconsin Superconducting Electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R.A. Bosch, K.J. Kleman, R.A. Legg

    2012-07-01

    The Wisconsin superconducting electron gun is modeled with multiparticle tracking simulations using the ASTRA and GPT codes. To specify the construction of the emittance-compensation solenoid, we studied the dependence of the output bunch's emittance upon the solenoid's strength and field errors. We also evaluated the dependence of the output bunch's emittance upon the bunch's initial emittance and the size of the laser spot on the photocathode. The results suggest that a 200-pC bunch with an emittance of about one mm-mrad can be produced for a free-electron laser.

  16. Note: Simulation and test of a strip source electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iqbal, Munawar, E-mail: muniqbal.chep@pu.edu.pk; Institute of High Energy Physics, Chinese Acedemy of Sciences, Beijing 100049; Islam, G. U.

    We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm{sup 2}, respectively, that corresponds to power density of 11.5 kW/cm{sup 2}, at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive.more » Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.« less

  17. A high-current electron gun for the electron beam ion trap at the National Superconducting Cyclotron Laboratory.

    PubMed

    Schwarz, S; Baumann, T M; Kittimanapun, K; Lapierre, A; Snyder, A

    2014-02-01

    The Electron Beam Ion Trap (EBIT) in NSCL's reaccelerator ReA uses continuous ion injection and accumulation. In order to maximize capture efficiency and minimize breeding time into high charge states, the EBIT requires a high-current/high current-density electron beam. A new electron gun insert based on a concave Ba-dispenser cathode has been designed and built to increase the current transmitted through the EBIT's superconducting magnet. With the new insert, stable EBIT operating conditions with 0.8 A of electron beam have been established. The design of the electron gun is presented together with calculated and measured perveance data. In order to assess the experimental compression of the electron beam, a pinhole CCD camera has been set up to measure the electron beam radius. The camera observes X-rays emitted from highly charged ions, excited by the electron beam. Initial tests with this camera setup will be presented. They indicate that a current density of 640 A/cm(2) has been reached when the EBIT magnet was operated at 4 T.

  18. A high-current electron gun for the electron beam ion trap at the National Superconducting Cyclotron Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwarz, S., E-mail: schwarz@nscl.msu.edu; Baumann, T. M.; Kittimanapun, K.

    The Electron Beam Ion Trap (EBIT) in NSCL’s reaccelerator ReA uses continuous ion injection and accumulation. In order to maximize capture efficiency and minimize breeding time into high charge states, the EBIT requires a high-current/high current-density electron beam. A new electron gun insert based on a concave Ba-dispenser cathode has been designed and built to increase the current transmitted through the EBIT’s superconducting magnet. With the new insert, stable EBIT operating conditions with 0.8 A of electron beam have been established. The design of the electron gun is presented together with calculated and measured perveance data. In order to assessmore » the experimental compression of the electron beam, a pinhole CCD camera has been set up to measure the electron beam radius. The camera observes X-rays emitted from highly charged ions, excited by the electron beam. Initial tests with this camera setup will be presented. They indicate that a current density of 640 A/cm{sup 2} has been reached when the EBIT magnet was operated at 4 T.« less

  19. Construction and Test of a Novel Superconducting RF Electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisognano, Joseph J.

    The University of Wisconsin-Madison has completed installation of a superconducting electron gun. Its concept was optimized to be the source for a CW free electron laser facility with multiple megahertz repetition rate end stations. This VHF superconducting configuration holds the promise of the highest performance for CW injectors. Initial commissioning efforts show that the cavity can achieve gradients of 35 MV/m at the cathode position. With the cathode inserted CW operation has been achieved at 20 MV/m with good control of microphonics, negligible dark current, and Q0 > 3×109 at 4 K. Bunch charges of ~100 pC have been delivered,more » and first simple beam measurements made. These preliminary results are very encouraging for production of 100s pC bunches with millimeter-milliradian or smaller normalized emittances. Plans are in place to carry out more definitive studies to establish the full capabilities. However, since the grant was not renewed, the electron gun is currently mothballed, and without supplemental fund the opportunity for further work will be lost.« less

  20. High-current electron gun with a planar magnetron integrated with an explosive-emission cathode

    NASA Astrophysics Data System (ADS)

    Kiziridi, P. P.; Ozur, G. E.

    2017-05-01

    A new high-current electron gun with plasma anode and explosive-emission cathode integrated with planar pulsed powered magnetron is described. Five hundred twelve copper wires 1 mm in diameter and 15 mm in height serve as emitters. These emitters are installed on stainless steel disc (substrate) with 3-mm distance between them. Magnetron discharge plasma provides increased ion density on the periphery of plasma anode formed by high-current Penning discharge ignited within several milliseconds after starting of the magnetron discharge. The increased on the periphery ion density improves the uniformity of high-current electron beam produced in such an electron gun.

  1. A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

    NASA Astrophysics Data System (ADS)

    Kumar, N.; Lamba, R. P.; Hossain, A. M.; Pal, U. N.; Phelps, A. D. R.; Prakash, R.

    2017-11-01

    The experimental study of a tapered, multi-gap, multi-aperture pseudospark-sourced electron gun based X-band plasma assisted slow wave oscillator is presented. The designed electron gun is based on the pseudospark discharge concept and has been used to generate a high current density and high energy electron beam simultaneously. The distribution of apertures has been arranged such that the field penetration potency inside the backspace of the hollow-cathode is different while passing through the tapered gap region. This leads to non-concurrent ignition of the discharge through all the channels which is, in general, quite challenging in the case of multi-aperture plasma cathode electron gun geometries. Multiple and successive hollow cathode phases are reported from this electron gun geometry, which have been confirmed using simulations. This geometry also has led to the achievement of ˜71% fill factor inside the slow wave oscillator for an electron beam of energy of 20 keV and a beam current density in the range of 115-190 A/cm2 at a working argon gas pressure of 18 Pa. The oscillator has generated broadband microwave output in the frequency range of 10-11.7 GHz with a peak power of ˜10 kW for ˜50 ns.

  2. Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy.

    PubMed

    Whelan, Brendan; Holloway, Lois; Constantin, Dragos; Oborn, Brad; Bazalova-Carter, Magdalena; Fahrig, Rebecca; Keall, Paul

    2016-11-01

    MRI-linac therapy is a rapidly growing field, and requires that conventional linear accelerators are operated with the fringe field of MRI magnets. One of the most sensitive accelerator components is the electron gun, which serves as the source of the beam. The purpose of this work was to develop a validated finite element model (FEM) model of a clinical triode (or gridded) electron gun, based on accurate geometric and electrical measurements, and to characterize the performance of this gun in magnetic fields. The geometry of a Varian electron gun was measured using 3D laser scanning and digital calipers. The electric potentials and emission current of these guns were measured directly from six dose matched true beam linacs for the 6X, 10X, and 15X modes of operation. Based on these measurements, a finite element model (FEM) of the gun was developed using the commercial software opera/scala. The performance of the FEM model in magnetic fields was characterized using parallel fields ranging from 0 to 200 G in the in-line direction, and 0-35 G in the perpendicular direction. The FEM model matched the average measured emission current to within 5% across all three modes of operation. Different high voltage settings are used for the different modes; the 6X, 10X, and 15X modes have an average high voltage setting of 15, 10, and 11 kV. Due to these differences, different operating modes show different sensitivities in magnetic fields. For in line fields, the first current loss occurs at 40, 20, and 30 G for each mode. This is a much greater sensitivity than has previously been observed. For perpendicular fields, first beam loss occurred at 8, 5, and 5 G and total beam loss at 27, 22, and 20 G. A validated FEM model of a clinical triode electron gun has been developed based on accurate geometric and electrical measurements. Three different operating modes were simulated, with a maximum mean error of 5%. This gun shows greater sensitivity to in-line magnetic fields than

  3. Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy

    PubMed Central

    Whelan, Brendan; Holloway, Lois; Constantin, Dragos; Oborn, Brad; Bazalova-Carter, Magdalena; Fahrig, Rebecca; Keall, Paul

    2016-01-01

    Purpose: MRI-linac therapy is a rapidly growing field, and requires that conventional linear accelerators are operated with the fringe field of MRI magnets. One of the most sensitive accelerator components is the electron gun, which serves as the source of the beam. The purpose of this work was to develop a validated finite element model (FEM) model of a clinical triode (or gridded) electron gun, based on accurate geometric and electrical measurements, and to characterize the performance of this gun in magnetic fields. Methods: The geometry of a Varian electron gun was measured using 3D laser scanning and digital calipers. The electric potentials and emission current of these guns were measured directly from six dose matched true beam linacs for the 6X, 10X, and 15X modes of operation. Based on these measurements, a finite element model (FEM) of the gun was developed using the commercial software opera/scala. The performance of the FEM model in magnetic fields was characterized using parallel fields ranging from 0 to 200 G in the in-line direction, and 0–35 G in the perpendicular direction. Results: The FEM model matched the average measured emission current to within 5% across all three modes of operation. Different high voltage settings are used for the different modes; the 6X, 10X, and 15X modes have an average high voltage setting of 15, 10, and 11 kV. Due to these differences, different operating modes show different sensitivities in magnetic fields. For in line fields, the first current loss occurs at 40, 20, and 30 G for each mode. This is a much greater sensitivity than has previously been observed. For perpendicular fields, first beam loss occurred at 8, 5, and 5 G and total beam loss at 27, 22, and 20 G. Conclusions: A validated FEM model of a clinical triode electron gun has been developed based on accurate geometric and electrical measurements. Three different operating modes were simulated, with a maximum mean error of 5%. This gun shows greater

  4. Mechanical design and fabrication of the VHF-gun, the Berkeley normal-conducting continuous-wave high-brightness electron source

    NASA Astrophysics Data System (ADS)

    Wells, R. P.; Ghiorso, W.; Staples, J.; Huang, T. M.; Sannibale, F.; Kramasz, T. D.

    2016-02-01

    A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. The basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.

  5. Mechanical design and fabrication of the VHF-gun, the Berkeley normal-conducting continuous-wave high-brightness electron source.

    PubMed

    Wells, R P; Ghiorso, W; Staples, J; Huang, T M; Sannibale, F; Kramasz, T D

    2016-02-01

    A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. The basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.

  6. Design of spherical electron gun for ultra high frequency, CW power inductive output tube

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaushik, Meenu, E-mail: mkceeri@gmail.com; Joshi, L. M., E-mail: lmj1953@gmail.com; Academy of Scientific and Innovative Research

    Inductive Output Tube (IOT) is an amplifier that usually operates in UHF range. It is an electron tube whose basic structure is similar to conventional vacuum devices. This device is widely used in broadcast applications but is now being explored for scientific applications also specifically, particle accelerators and fusion plasma heating purposes. The paper describes the design approach of a spherical gridded electron gun of a 500 MHz, 100 kW CW power IOT. The electron gun structure has been simulated and optimized for operating voltage and current of 40kV and 3.5 A respectively. The electromagnetic analysis of this spherical electron gunmore » has been carried out in CST and TRAK codes.« less

  7. Study on the steady operating state of a micro-pulse electron gun.

    PubMed

    Kui, Zhou; Xiangyang, Lu; Shengwen, Quan; Jifei, Zhao; Xing, Luo; Ziqin, Yang

    2014-09-01

    Micro-pulse electron gun (MPG) employs the basic concept of multipacting to produce high-current and short-pulse electron beams from a radio-frequency (RF) cavity. The concept of MPG has been proposed for more than two decades. However, the unstable operating state of MPG vastly obstructs its practical applications. This paper presents a study on the steady operating state of a micro-pulse electron gun with theory and experiments. The requirements for the steady operating state are proposed through the analysis of the interaction between the RF cavity and the beam load. Accordingly, a MPG cavity with the frequency of 2856 MHz has been designed, constructed, and tested. Some primary experiments have been finished. Both the unstable and stable operating states of the MPG have been observed. The stable output beam current has been detected at about 3.8 mA. Further experimental study is under way now.

  8. 46th Annual Gun and Missile Systems Conference and Exhibition

    DTIC Science & Technology

    2011-09-01

    Grade Sensors Through Use of Accelerated Aging Principles Mr. Scott Gift 11657 Modeling of the Autofrettage Processes of a Gun Barrel Mr. Sudhir...Emissions Measured on the Outer Portion of a Composite Barrel Ms. Rushie Ghimire GUN & MISSILE SYSTEMS ADDITIONAL AUTHORS GUN & MISSILE SYSTEMS...X 3BCT 2BCT X 1BCT TACP COLT • BLUFOR scout squad engaged by enemy infantry and are overwhelmed by heavy machine gun fire 100m to their northwest

  9. Water gun vs air gun: A comparison

    USGS Publications Warehouse

    Hutchinson, D.R.; Detrick, R. S.

    1984-01-01

    The water gun is a relatively new marine seismic sound source that produces an acoustic signal by an implosive rather than explosive mechanism. A comparison of the source characteristics of two different-sized water guns with those of conventional air guns shows the the water gun signature is cleaner and much shorter than that of a comparable-sized air gun: about 60-100 milliseconds (ms) for an 80-in3. (1.31-liter (I)) water gun compared with several hundred ms for an 80-in3. (1.31-1) air gun. The source spectra of water guns are richer in high frequencies (>200 Hz) than are those of air guns, but they also have less energy than those of air guns at low frequencies. A comparison between water gun and air gun reflection profiles in both shallow (Long Island Sound)-and deep (western Bermuda Rise)-water settings suggests that the water gun offers a good compromise between very high resolution, limited penetration systems (e.g. 3.5-kHz profilers and sparkers) and the large volume air guns and tuned air gun arrays generally used where significant penetration is required. ?? 1984 D. Reidel Publishing Company.

  10. Study on the steady operating state of a micro-pulse electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kui, Zhou; Xing, Luo; Institute of Applied Electronics, Chinese Academy of Engineering Physics, Mianyang 621900

    Micro-pulse electron gun (MPG) employs the basic concept of multipacting to produce high-current and short-pulse electron beams from a radio-frequency (RF) cavity. The concept of MPG has been proposed for more than two decades. However, the unstable operating state of MPG vastly obstructs its practical applications. This paper presents a study on the steady operating state of a micro-pulse electron gun with theory and experiments. The requirements for the steady operating state are proposed through the analysis of the interaction between the RF cavity and the beam load. Accordingly, a MPG cavity with the frequency of 2856 MHz has been designed,more » constructed, and tested. Some primary experiments have been finished. Both the unstable and stable operating states of the MPG have been observed. The stable output beam current has been detected at about 3.8 mA. Further experimental study is under way now.« less

  11. Modular Low-Heater-Power Cathode/Electron Gun Assembly for Microwave and Millimeter Wave Traveling Wave Tubes

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.

    2000-01-01

    A low-cost, low-mass, electrically efficient, modular cathode/electron gun assembly has been developed by FDE Inc. of Beaverton, Oregon, under a Small Business Innovation Research (SBIR) contract with the NASA Glenn Research Center at Lewis Field. This new assembly offers significant improvements in the design and manufacture of microwave and millimeter wave traveling-wave tubes (TWT's) used for radar and communications. It incorporates a novel, low-heater-power, reduced size and mass, high-performance barium dispenser type thermionic cathode and provides for easy integration of the cathode into a large variety of conventional TWT circuits. Among the applications are TWT's for Earth-orbiting communication satellites and for deep space communications, where future missions will require smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. A particularly important TWT application is in the microwave power module (a hybrid microwave/millimeter wave amplifier consisting of a low-noise solid-state driver, a small TWT, and an electronic power conditioner integrated into a single compact package), where electrical efficiency and thermal loading are critical factors and lower cost is needed for successful commercialization. The design and fabrication are based on practices used in producing cathode ray tubes (CRT's), which is one of the most competitive and efficient manufacturing operations in the world today. The approach used in the design and manufacture of thermionic cathodes and electron guns for CRT's has been optimized for fully automated production, standardization of parts, and minimization of costs. It is applicable to the production of similar components for microwave tubes, with the additional benefits of low mass and significantly lower cathode heater power (less than half that of dispenser cathodes presently used in TWT s). Modular cathode/electron gun assembly. The modular

  12. Youth, Guns, and the Juvenile Justice System. Research Report.

    ERIC Educational Resources Information Center

    Butts, Jeffrey; Coggeshall, Mark; Gouvis, Caterina; Mears, Daniel; Travis, Jeremy; Waul, Michelle; White, Ruth

    This report documents trends in youth gun violence and the response within the justice system, noting the growing variety of data resources available to investigate the effect of new gun laws on youth, communities, and public safety. The first section reviews recent trends, examining the major wave of gun violence in the United States during the…

  13. The design of electron and ion guns, beams, and collectors

    NASA Astrophysics Data System (ADS)

    Becker, Reinard; Herrmannsfeldt, William B.

    2004-01-01

    The well known `SLAC Electron Trajectory Program' (EGUN) has been ported to PCs and has been developed into a family of programs for the design and the optimization of particle optics devices including electron and ion guns, beam transport sections and collectors. We will discuss the application of these tools for the design and the optimization of the essential parts of EBIS/T devices. The discussion will include conditions in which restrictions in the reliability of simulations may occur due to the mathematical modeling and how to overcome them.

  14. Experimental investigation of electron guns for THz microwave vacuum amplifiers

    NASA Astrophysics Data System (ADS)

    Burtsev, A. A.; Grigor'ev, Yu. A.; Navrotsky, I. A.; Rogovin, V. I.; Sakhadzhi, G. V.; Shumikhin, K. V.

    2016-05-01

    Single-sheet and multiple beam electron emitters based on thermionic minicathodes for terahertz traveling-wave tubes have been studied. Data are presented for impregnated blade thermionic cathode with dimensions 0.1 × 0.7 mm and a maximum current density of 114 A/cm2 in a pulsed mode. A variant of the five-beam electron gun with 0.25-mm-diameter cylindrical minicathodes in cells of a control grid is proposed that provides a current density of 85.5 A/cm2 at a grid potential of 900-1000 V.

  15. Electron beam simulation from gun to collector: Towards a complete solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mertzig, R., E-mail: robert.mertzig@cern.ch; Shornikov, A., E-mail: robert.mertzig@cern.ch; Wenander, F.

    An electron-beam simulation technique for high-resolution complete EBIS/T modelling is presented. The technique was benchmarked on the high compression HEC{sup 2} test-stand with an electron beam current, current density and energy of 10 A, 10 kA/cm{sup 2} and 49.2 keV, and on the immersed electron beam at REXEBIS for electron beam characteristics of 0.4 A, 200 A/cm{sup 2} and 4.5 keV. In both Brillouin-like and immersed beams the electron-beam radius varies from several millimeters at the gun, through some hundreds of micrometers in the ionization region to a few centimeters at the collector over a total length of several meters.more » We report on our approach for finding optimal meshing parameters, based on the local beam properties such as magnetic field-strength, electron energy and beam radius. This approach combined with dividing the problem domain into sub-domains, and subsequent splicing of the local solutions allowed us to simulate the beam propagation in EBISes from the gun to the collector using a conventional PC in about 24–36 h. Brillouin-like electron beams propagated through the complete EBIS were used to analyze the beam behavior within the collector region. We checked whether elastically reflected paraxial electrons from a Brillouin-like beam will escape from the collector region and add to the loss current. We have also studied the power deposition profiles as function of applied potentials using two electrode geometries for a Brillouin-like beam including the effects of backscattered electrons.« less

  16. Ion tracking in photocathode rf guns

    NASA Astrophysics Data System (ADS)

    Lewellen, John W.

    2002-02-01

    Projected next-generation linac-based light sources, such as PERL or the TESLA free-electron laser, generally assume, as essential components of their injector complexes, long-pulse photocathode rf electron guns. These guns, due to their design rf pulse durations of many milliseconds to continuous wave, may be more susceptible to ion bombardment damage of their cathodes than conventional rf guns, which typically use rf pulses of microsecond duration. This paper explores this possibility in terms of ion propagation within the gun, and presents a basis for future study of the subject.

  17. Off-axis beam dynamics in rf-gun-based electron photoinjectors

    DOE PAGES

    Huang, R.; Mitchell, Chad; Papadopoulos, C.; ...

    2016-11-22

    The need to operate an rf-gun-based electron photoinjector with a beam emitted away from the cathode center can occur under various circumstances. First, in some cases the cathode can be affected by ion back-bombardment that progressively reduces the quantum efficiency (QE) in its center, making off-axis operation mandatory; second, in some cases the drive laser intensity can be sufficiently high to generate QE depletion in the cathode area illuminated by the laser, forcing off-axis operation; last, in cathodes with nonuniform QE distribution it could be convenient to operate off axis to exploit a better QE. However, operation in this modemore » may lead to growth of the projected transverse beam emittances due to correlations between the transverse and longitudinal degrees of freedom that are introduced within the gun and downstream rf cavities. A strategy is described to mitigate this emittance growth by allowing the beam to propagate along a carefully tuned off-axis trajectory in downstream rf cavities to remove the time-dependent rf kicks introduced in the gun. Along this trajectory, short range wakefields do not degrade the emittance, and long range wakefields degrade the emittance for very high repetition rate only.« less

  18. Off-axis beam dynamics in rf-gun-based electron photoinjectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, R.; Mitchell, Chad; Papadopoulos, C.

    The need to operate an rf-gun-based electron photoinjector with a beam emitted away from the cathode center can occur under various circumstances. First, in some cases the cathode can be affected by ion back-bombardment that progressively reduces the quantum efficiency (QE) in its center, making off-axis operation mandatory; second, in some cases the drive laser intensity can be sufficiently high to generate QE depletion in the cathode area illuminated by the laser, forcing off-axis operation; last, in cathodes with nonuniform QE distribution it could be convenient to operate off axis to exploit a better QE. However, operation in this modemore » may lead to growth of the projected transverse beam emittances due to correlations between the transverse and longitudinal degrees of freedom that are introduced within the gun and downstream rf cavities. A strategy is described to mitigate this emittance growth by allowing the beam to propagate along a carefully tuned off-axis trajectory in downstream rf cavities to remove the time-dependent rf kicks introduced in the gun. Along this trajectory, short range wakefields do not degrade the emittance, and long range wakefields degrade the emittance for very high repetition rate only.« less

  19. Testing a GaAs cathode in SRF gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Kewisch, J.; Ben-Zvi, I.

    RF electron guns with a strained superlattice GaAs cathode are expected to generate polarized electron beams of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface and lower cathode temperature. We plan to install a bulk GaAs:Cs in a SRF gun to evaluate the performance of both the gun and the cathode in this environment. The status of this project is: In our 1.3 GHz 1/2 cell SRF gun, the vacuum can be maintained at nearly 10{sup -12} Torr because of cryo-pumping at 2K. With conventional activation of bulk GaAs,more » we obtained a QE of 10% at 532 nm, with lifetime of more than 3 days in the preparation chamber and have shown that it can survive in transport from the preparation chamber to the gun. The beam line has been assembled and we are exploring the best conditions for baking the cathode under vacuum. We report here the progress of our test of the GaAs cathode in the SRF gun. Future particle accelerators, such as eRHIC and the ILC require high-brightness, high-current polarized electrons. Strained superlattice GaAs:Cs has been shown to be an efficient cathode for producing polarized electrons. Activation of GaAs with Cs,O(F) lowers the electron affinity and makes it energetically possible for all the electrons, excited into the conduction band that drift or diffuse to the emission surface, to escape into the vacuum. Presently, all operating polarized electron sources, such as the CEBAF, are DC guns. In these devices, the excellent ultra-high vacuum extends the lifetime of the cathode. However, the low field gradient on the photocathode's emission surface of the DC guns limits the beam quality. The higher accelerating gradients, possible in the RF guns, generate a far better beam. Until recently, most RF guns operated at room temperature, limiting the vacuum to {approx}10{sup -9} Torr. This destroys the GaAs's NEA surface. The SRF guns combine the excellent vacuum conditions of DC guns and the

  20. TU-H-BRA-03: Performance of a Clinical Gridded Electron Gun in Magnetic Fields: Implications for MRI-Linac Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whelan, B; Keall, P; Bazalova-Carter, M

    Purpose: Recent advances towards MRI Linac radiotherapy have motivated a wide range of studies characterizing electromagnetic interactions between the two devices. One of the most sensitive components is the linac electron gun. To data, only non gridded (diode) guns have been investigated however, most linac vendors utilize gridded (triode) guns, which enable efficient and robust beam gating. The purpose of this study was to develop a realistic model of a gridded gun used clinically, and to characterize its performance in magnetic fields. Methods: The gridded electron gun used on Varian high energy machines was measured using 3D laser scanning quotedmore » as accurate to 0.1mm. Based on the scane, a detailed CAD mode was developed. From this, key geometry was extracted and a FEM model was developed (Opera/SCALA). Next, the high voltage (HV), grid voltage, and emission current were read from six dose matched TrueBeam linacs for the 6X, 10X and 15X photon modes (0 B-field). The mean values were used to represent each mode, which was simulated I constant magnetic fields from 0–200G in-line, and 0–35G perpendicular. Results: Experimentally measured HV, grid voltage, and emission current from 6X, 10X and 15X modes were respectively: 15±.03kV, 10±.08kV, 11±.03kV; 93±7V, 41±3V, and 70±6V; 327±27mA, 129±10mA, and 214±19mA. The error in simulated emission current of each mode was 3%,6%, and 3%. For in-line fields, 50% beam loss occurred at 114, 96, and 97G; for perpendicular; at 12, 13 and 14G. Sensitivity for a given geometry is primarily determined by HV setting. Conclusion: Future MRI-Linac systems will almost certainly use gridded guns. We present the first model of a clinical gridded gun, and match the experimental emission current to within 6% across three different operating modes. This clinical gun shows increased sensitivity to magnetic fields than previous work,and different modes show different sensitivity.« less

  1. Magneto-Optic Kerr Effect in a Magnetized Electron Gun

    NASA Astrophysics Data System (ADS)

    Hardy, Benjamin; Grames, Joseph; CenterInjectors; Sources Team

    2016-09-01

    Magnetized electron sources have the potential to improve ion beam cooling efficiency. At the Gun Test Stand at Jefferson Lab, a solenoid magnet will be installed adjacent to the photogun to magnetize the electron beam. Due to the photocathode operating in a vacuum chamber, measuring and monitoring the magnetic field at the beam source location with conventional probes is impractical. The Magneto-Optical Kerr Effect (MOKE) describes the change on polarized light by reflection from a magnetized surface. The reflection from the surface may alter the polarization direction, ellipticity, or intensity, and depends linearly upon the surface magnetization of the sample. By replacing the photocathode with a magnetized sample and reflecting polarized light from the sample surface, the magnetic field at the beam source is inferred. A controlled MOKE system has been assembled to test the magnetic field. Calibration of the solenoid magnet is performed by comparing the MOKE signal with magnetic field measurements. The apparatus will provide a description of the field at electron beam source. The report summarizes the method and results of controlled tests and calibration of the MOKE sample with the solenoid magnet field measurements. This work is supported by the National Science Foundation, Research Experience for Undergraduates Award 1359026 and the Department of Energy, Laboratory Directed Research and Development Contract DE-AC05-06OR23177.

  2. Design, Fabrication and Testing of a Satellite Electron Beam System.

    DTIC Science & Technology

    1980-05-16

    Oide , ft necessar and fdernuhv b blockr ... mber) Desiqn, Development, Fabrication and Test of Electron Beam System for use in a Satellite Vehicle. DD...1.6 Dscription oF SP:BS The SPIBS instrument was a two centimeter diameter ion source using Xenon gas as the expellant, having a hollow cathode with an...fully tested using dummy guns. Special gun opening tests using real guns were employed in vacuum tests to determine that there was no cathode poison

  3. Development of 50kV air-core transformer for electron gun static power source of 3MeV DC accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewangan, S.; Bakhtsingh, R.I.; Rajan, R.N.

    A 3 MeV, 10 mA DC Electron Beam Accelerator based on the capacitively coupled parallel-fed voltage multiplier in 6 kg/cm{sup 2} SF{sub 6} gas environment is under commissioning at Electron Beam Centre, Kharghar, Navi Mumbai. Electron Gun is situated at -3 MV terminal which requires a constant power for its anode and filament. Gun power source has been derived by suitably coupling the ac components present in the HV Multiplier column. An aircore step down transformer rated for 50kV/600V/120kHz floating at 3 MV to extract the required power for electron gun from high voltage column has been developed. The transformermore » has been operated for 7 kW, 1 MeV of electron beam in 6 kg/cm{sup 2} nitrogen gas environment. The paper describes briefly about the design aspects and test results. (author)« less

  4. 46th Annual Gun and Missile Systems Conference and Exhibition. Volume 3 - Thursday

    DTIC Science & Technology

    2011-09-01

    Grade Sensors Through Use of Accelerated Aging Principles Mr. Scott Gift 11657 Modeling of the Autofrettage Processes of a Gun Barrel Mr. Sudhir...Emissions Measured on the Outer Portion of a Composite Barrel Ms. Rushie Ghimire GUN & MISSILE SYSTEMS ADDITIONAL AUTHORS GUN & MISSILE SYSTEMS...Transportation – Loading – Gun Fire to Barrel Exit – After Barrel Exit • Passing: Fuze safety devices remain safe; safe for disposal or safe for

  5. A new design of indirectly heated cathode based strip type electron gun.

    PubMed

    Maiti, Namita; Lijeesh, K; Barve, U D; Quadri, Nishad; Tembhare, G U; Mukherjee, S; Thakur, K B; Das, A K

    2013-08-01

    A new design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The design issue addressed is the uniformity of temperature on the solid cathode using (a) a multi-segmented filament with variable height as the primary heat source and (b) trapezoidal shaped single long filament as the primary heat source. The proposed design in this paper is based on computer simulation and validated by extensive experimentations. The design emphasis is on maintaining uniform temperature on the solid cathode. The designed multi-segment filament and the single long filament provide a temperature uniformity on the solid cathode of about 250 K and 110 K, respectively. The better temperature uniformity inspite of the thermal expansion, in case of a single long filament tightly clamped at two ends, has been possible due to shaping of the single filament with a number of constituent sections such that the thermal expansion of different sections forming the actual filament takes care of not only the mechanical stability but also does not affect the emitting surface of the filament. Experiments show that the modified design achieves a one to one correspondence of the solid cathode length and the electron beam length emitted from the solid cathode.

  6. A high-compression electron gun for C6+ production: concept, simulations and mechanical design

    NASA Astrophysics Data System (ADS)

    Mertzig, Robert; Breitenfeldt, M.; Mathot, S.; Pitters, J.; Shornikov, A.; Wenander, F.

    2017-07-01

    In this paper we report on simulations and the mechanical design of a high-compression electron gun for an Electron Beam Ion Source (EBIS) dedicated for production of high intensity and high repetition rate pulses of bare carbon ions for injection into linac-based hadron therapy facilities. The gun is presently under construction at CERN to be retrofitted into the TwinEBIS test bench for experimental studies. We describe the design constraints, show results of numeric simulations and report on the mechanical design featuring several novel ideas. The reported design makes use of combined-function units with reduced number of mechanical joints that were carefully controlled and tuned during the manufacturing phase. The simulations addressed a wide range of topics including the influence of thermal effects, focusing optics, symmetry-breaking misalignments and injection into a full 5 T field.

  7. Diagnostic for a high-repetition rate electron photo-gun and first measurements

    NASA Astrophysics Data System (ADS)

    Filippetto, D.; Doolittle, L.; Huang, G.; Norum, E.; Portmann, G.; Qian, H.; Sannibale, F.

    2015-05-01

    The APEX electron source at LBNL combines the high-repetition-rate with the high beam brightness typical of photoguns, delivering low emittance electron pulses at MHz frequency. Proving the high beam quality of the beam is an essential step for the success of the experiment, opening the doors of the high average power to brightness-hungry applications as X-Ray FELs, MHz ultrafast electron diffraction etc.. As first step, a complete characterization of the beam parameters is foreseen at the Gun beam energy of 750 keV. Diagnostics for low and high current measurements have been installed and tested, and measurements of cathode lifetime and thermal emittance in a RF environment with mA current performed. The recent installation of a double slit system, a deflecting cavity and a high precision spectrometer, allow the exploration of the full 6D phase space. Here we discuss the present layout of the machine and future upgrades, showing the latest results at low and high repetition rate, together with the tools and techniques used.

  8. Nonadiabatic Electron-Optical System of a Technological Gyrotron

    NASA Astrophysics Data System (ADS)

    Goldenberg, A. L.; Glyavin, M. Yu.; Leshcheva, K. A.; Manuilov, V. N.

    2017-10-01

    We consider a new version of the nonadiabatic system for the formation of a helical electron beam in a gyrotron, in which electrons acquire initial oscillatory velocities when a rectilinear beam is injected at an angle to the magnetic field. In such an electron gun, the influence of thermal electron velocities and roughness of the emitting surface can be decreased, as compared with the conventional electron-optical systems of gyrotrons. This makes it possible to increase significantly the system efficiency. The main factors affecting the quality of the formed beam are considered.

  9. Application of electron beam equipment based on a plasma cathode gun in additive technology

    NASA Astrophysics Data System (ADS)

    Galchenko, N. K.; Kolesnikova, K. A.; Semenov, G. V.; Rau, A. G.; Raskoshniy, S. Y.; Bezzubko, A. V.; Dampilon, B. V.; Sorokova, S. N.

    2016-11-01

    The paper discusses the application of electron beam equipment based on a plasma cathode gun for three-dimensional surface modification of metals and alloys. The effect of substrate surface preparation on the adhesion strength of gas thermal coatings has been investigated.

  10. Portable Electron-Beam Free-Form Fabrication System

    NASA Technical Reports Server (NTRS)

    Watson, J. Kevin; Petersen, Daniel D.; Taminger, Karen M.; Hafley, Robert A.

    2005-01-01

    A portable electron-beam free-form fabrication (EB F3) system, now undergoing development, is intended to afford a capability for manufacturing metal parts in nearly net sizes and shapes. Although the development effort is oriented toward the eventual use of systems like this one to supply spare metal parts aboard spacecraft in flight, the basic system design could also be adapted to terrestrial applications in which there are requirements to supply spare parts on demand at locations remote from warehouses and conventional manufacturing facilities. Prior systems that have been considered for satisfying the same requirements (including prior free-form fabrication systems) are not easily portable because of their bulk and massive size. The mechanical properties of the components that such systems produce are often inferior to the mechanical properties of the corresponding original, conventionally fabricated components. In addition, the prior systems are not efficient in the utilization of energy and of feedstock. In contrast, the present developmental system is designed to be sufficiently compact and lightweight to be easily portable, to utilize both energy and material more efficiently, and to produce components that have mechanical properties approximating those of the corresponding original components. The developmental EB F3 system will include a vacuum chamber and associated vacuum pumps, an electron-beam gun and an associated power supply, a multiaxis positioning subsystem, a precise wire feeder, and an instrumentation system for monitoring and control. The electron-beam gun, positioning subsystem, and wire feeder will be located inside the vacuum chamber (see figure). The electron beam gun and the wire feeder will be mounted in fixed positions inside the domed upper portion of the vacuum chamber. The positioning subsystem and ports for the vacuum pumps will be located on a base that could be dropped down to provide full access to the interior of the chamber

  11. An X-Band Gun Test Area at SLAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C.; Adolphsen, C.; Chu, T.S.

    The X-Band Test Area (XTA) is being assembled in the NLCTA tunnel at SLAC to serve as a test facility for new RF guns. The first gun to be tested will be an upgraded version of the 5.6 cell, 200 MV/m peak field X-band gun designed at SLAC in 2003 for the Compton Scattering experiment run in ASTA. This new version includes some features implemented in 2006 on the LCLS gun such as racetrack couplers, increased mode separation and elliptical irises. These upgrades were developed in collaboration with LLNL since the same gun will be used in an injector formore » a LLNL Gamma-ray Source. Our beamline includes an X-band acceleration section which takes the electron beam up to 100 MeV and an electron beam measurement station. Other X-Band guns such as the UCLA Hybrid gun will be characterized at our facility.« less

  12. Gun ownership and social gun culture

    PubMed Central

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-01-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. PMID:26124073

  13. Conceptual Design for CLIC Gun Pulser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Tao

    The Compact Linear Collider (CLIC) is a proposed future electron-positron collider, designed to perform collisions at energies from 0.5 to 5 TeV, with a nominal design optimized for 3 TeV (Dannheim, 2012). The Drive Beam Accelerator consists of a thermionic DC gun, bunching section and an accelerating section. The thermionic gun needs deliver a long (~143us) pulse of current into the buncher. A pulser is needed to drive grid of the gun to generate a stable current output. This report explores the requirements of the gun pulser and potential solutions to regulate grid current.

  14. Parallel 3D Finite Element Numerical Modelling of DC Electron Guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prudencio, E.; Candel, A.; Ge, L.

    2008-02-04

    In this paper we present Gun3P, a parallel 3D finite element application that the Advanced Computations Department at the Stanford Linear Accelerator Center is developing for the analysis of beam formation in DC guns and beam transport in klystrons. Gun3P is targeted specially to complex geometries that cannot be described by 2D models and cannot be easily handled by finite difference discretizations. Its parallel capability allows simulations with more accuracy and less processing time than packages currently available. We present simulation results for the L-band Sheet Beam Klystron DC gun, in which case Gun3P is able to reduce simulation timemore » from days to some hours.« less

  15. Where the guns come from: the gun industry and gun commerce.

    PubMed

    Wintemute, Garen J

    2002-01-01

    Under federal law, it is illegal for youth under age 18 to purchase rifles or shotguns, and for those under age 21 to purchase handguns. However, fatality and injury statistics clearly show that guns are finding their way into young people's hands. Many of these youth obtain guns through illegal gun markets. This article focuses on how guns in the United States are manufactured, marketed, and sold. The article shows how the legal and illegal gun markets are intimately connected and make guns easily accessible to youth. Although the domestic gun manufacturing industry is relatively small and has experienced declining sales in recent years, it has significant political clout and a large market for its products, and has engaged in aggressive marketing to youth. Lax oversight of licensed firearms dealers, combined with little or no regulation of private sales between gun owners, mean that guns can quickly moved from the legal gun market into the illegal market, where they can be acquired by young people. Certain guns, especially inexpensive, poorly made small handguns, are particularly attractive to criminals and youth. The author observes that several policy innovations--including increased regulation of licensed firearms dealers, intensified screening of prospective buyers, regulation of private sales, gun licensing and registration, and bans on some types of weapons--hold promise for decreasing the flow of guns into the hands of youth.

  16. Cathode performance during two beam operation of the high current high polarization electron gun for eRHIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahman, O.; Ben-Zvi, I.; Degen, C.

    Two electron beams from two activated bulk GaAs photocathodes were successfully combined during the recent beam test of the High Current High Polarization Electron gun for eRHIC. The beam test took place in Stangenes Industries in Palo Alto, CA, where the cathodes were placed in diagonally opposite locations inside the high voltage shroud. No significant cross talking between the cathodes was found for the pertinent vacuum and low average current operation, which is very promising towards combining multiple beams for higher average current. This paper describes the cathode preparation, transport and cathode performance in the gun for the combining test,more » including the QE and lifetimes of the photocathodes at various steps of the experiment.« less

  17. Gun ownership and social gun culture.

    PubMed

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-06-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Remote liquid target loading system for LANL two-stage gas gun

    NASA Astrophysics Data System (ADS)

    Gibson, L. L.; Bartram, B.; Dattelbaum, D. M.; Sheffield, S. A.; Stahl, D. B.

    2009-06-01

    A Remote Liquid Loading System (RLLS) was designed to load high hazard liquid materials into targets for gas-gun driven impact experiments. These high hazard liquids tend to react with confining materials in a short period of time, degrading target assemblies and potentially building up pressure through the evolution of gas in the reactions. Therefore, the ability to load a gas gun target in place immediately prior to firing the gun, provides the most stable and reliable target fielding approach. We present the design and evaluation of a RLLS built for the LANL two-stage gas gun. Targets for the gun are made of PMMA and assembled to form a liquid containment cell with a volume of approximately 25 cc. The compatibility of materials was a major consideration in the design of the system, particularly for its use with highly concentrated hydrogen peroxide. Teflon and 304-stainless steel were the two most compatible materials with the materials to be tested. Teflon valves and tubing, as well as stainless steel tubing, were used to handle the liquid, along with a stainless steel reservoir. Preliminary testing was done to ensure proper flow rate and safety. The system has been used to successfully load 97.5 percent hydrogen peroxide into a target cell just prior to a successful multiple magnetic gauge experiment. TV cameras on the target verified the bubble-free filling operation.

  19. A gas-loading system for LANL two-stage gas guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gibson, Lloyd Lee; Bartram, Brian Douglas; Dattelbaum, Dana Mcgraw

    A novel gas loading system was designed for the specific application of remotely loading high purity gases into targets for gas-gun driven plate impact experiments. The high purity gases are loaded into well-defined target configurations to obtain Hugoniot states in the gas phase at greater than ambient pressures.The small volume of the gas samples is challenging, as slight changing in the ambient temperature result in measurable pressure changes. Therefore, the ability to load a gas gun target and continually monitor the sample pressure prior to firing provides the most stable and reliable target fielding approach. We present the design andmore » evaluation of a gas loading system built for the LANL 50 mm bore two-stage light gas gun. Targets for the gun are made of 6061 Al or OFHC Cu, and assembled to form a gas containment cell with a volume of approximately 1.38 cc. The compatibility of materials was a major consideration in the design of the system, particularly for its use with corrosive gases. Piping and valves are stainless steel with wetted seals made from Kalrez® and Teflon®. Preliminary testing was completed to ensure proper flow rate and that the proper safety controls were in place. The system has been used to successfully load Ar, Kr, Xe, and anhydrous ammonia with purities of up to 99.999 percent. The design of the system and example data from the plate impact experiments will be shown.« less

  20. A gas-loading system for LANL two-stage gas guns

    NASA Astrophysics Data System (ADS)

    Gibson, L. L.; Bartram, B. D.; Dattelbaum, D. M.; Lang, J. M.; Morris, J. S.

    2017-01-01

    A novel gas loading system was designed for the specific application of remotely loading high purity gases into targets for gas-gun driven plate impact experiments. The high purity gases are loaded into well-defined target configurations to obtain Hugoniot states in the gas phase at greater than ambient pressures. The small volume of the gas samples is challenging, as slight changing in the ambient temperature result in measurable pressure changes. Therefore, the ability to load a gas gun target and continually monitor the sample pressure prior to firing provides the most stable and reliable target fielding approach. We present the design and evaluation of a gas loading system built for the LANL 50 mm bore two-stage light gas gun. Targets for the gun are made of 6061 Al or OFHC Cu, and assembled to form a gas containment cell with a volume of approximately 1.38 cc. The compatibility of materials was a major consideration in the design of the system, particularly for its use with corrosive gases. Piping and valves are stainless steel with wetted seals made from Kalrez® and Teflon®. Preliminary testing was completed to ensure proper flow rate and that the proper safety controls were in place. The system has been used to successfully load Ar, Kr, Xe, and anhydrous ammonia with purities of up to 99.999 percent. The design of the system and example data from the plate impact experiments will be shown.

  1. Design of a 300-kV gas environmental transmission electron microscope equipped with a cold field emission gun.

    PubMed

    Isakozawa, Shigeto; Nagaoki, Isao; Watabe, Akira; Nagakubo, Yasuhira; Saito, Nobuhiro; Matsumoto, Hiroaki; Zhang, Xiao Feng; Taniguchi, Yoshifumi; Baba, Norio

    2016-08-01

    A new in situ environmental transmission electron microscope (ETEM) was developed based on a 300 kV TEM with a cold field emission gun (CFEG). Particular caution was taken in the ETEM design to assure uncompromised imaging and analytical performance of the TEM. Because of the improved pumping system between the gun and column, the vacuum of CFEG was largely improved and the probe current was sufficiently stabilized to operate without tip flashing for 2-3 h or longer. A high brightness of 2.5 × 10(9) A/cm(2) sr was measured at 300 kV, verifying the high quality of the CFEG electron beam. A specially designed gas injection-heating holder was used in the in situ TEM study at elevated temperatures with or without gas around the TEM specimen. Using this holder in a 10 Pa gas atmosphere and specimen temperatures up to 1000°C, high-resolution ETEM performance and analysis were achieved. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Large Bore Powder Gun Qualification (U)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rabern, Donald A.; Valdiviez, Robert

    A Large Bore Powder Gun (LBPG) is being designed to enable experimentalists to characterize material behavior outside the capabilities of the NNSS JASPER and LANL TA-55 PF-4 guns. The combination of these three guns will create a capability to conduct impact experiments over a wide range of pressures and shock profiles. The Large Bore Powder Gun will be fielded at the Nevada National Security Site (NNSS) U1a Complex. The Complex is nearly 1000 ft below ground with dedicated drifts for testing, instrumentation, and post-shot entombment. To ensure the reliability, safety, and performance of the LBPG, a qualification plan has beenmore » established and documented here. Requirements for the LBPG have been established and documented in WE-14-TR-0065 U A, Large Bore Powder Gun Customer Requirements. The document includes the requirements for the physics experiments, the gun and confinement systems, and operations at NNSS. A detailed description of the requirements is established in that document and is referred to and quoted throughout this document. Two Gun and Confinement Systems will be fielded. The Prototype Gun will be used primarily to characterize the gun and confinement performance and be the primary platform for qualification actions. This gun will also be used to investigate and qualify target and diagnostic modifications through the life of the program (U1a.104 Drift). An identical gun, the Physics Gun, will be fielded for confirmatory and Pu experiments (U1a.102D Drift). Both guns will be qualified for operation. The Gun and Confinement System design will be qualified through analysis, inspection, and testing using the Prototype Gun for the majority of process. The Physics Gun will be qualified through inspection and a limited number of qualification tests to ensure performance and behavior equivalent to the Prototype gun. Figure 1.1 shows the partial configuration of U1a and the locations of the Prototype and Physics Gun/Confinement Systems.« less

  3. Multiobjective optimizations of a novel cryocooled dc gun based ultrafast electron diffraction beam line

    NASA Astrophysics Data System (ADS)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan

    2016-09-01

    We present the results of multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line utilizing a 225 kV dc gun with a novel cryocooled photocathode system and buncher cavity. Optimizations of the transverse projected emittance as a function of bunch charge are presented and discussed in terms of the scaling laws derived in the charge saturation limit. Additionally, optimization of the transverse coherence length as a function of final rms bunch length at the sample location have been performed for three different sample radii: 50, 100, and 200 μ m , for two final bunch charges: 1 05 electrons (16 fC) and 1 06 electrons (160 fC). Example optimal solutions are analyzed, and the effects of disordered induced heating estimated. In particular, a relative coherence length of Lc ,x/σx=0.27 nm /μ m was obtained for a final bunch charge of 1 05 electrons and final bunch length of σt≈100 fs . For a final charge of 1 06 electrons the cryogun produces Lc ,x/σx≈0.1 nm /μ m for σt≈100 - 200 fs and σx≥50 μ m . These results demonstrate the viability of using genetic algorithms in the design and operation of ultrafast electron diffraction beam lines.

  4. Beam energy spread in FERMI@elettra gun and linac induced by intrabeam scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zholents, Alexander A; Zholents, Alexander A; Zolotorev, Max S.

    Intrabeam scattering (IBS) of electrons in the pre-cathode area in the electron guns know in the literature as Boersh effect is responsible for a growth of the electron beam energy spread there. Albeit most visible within the electron gun where the electron beam density is large and the energy spread is small, the IBS acts all along the entire electron beam pass through the Linac. In this report we calculate the energy spread induced by IBS in the FERMI@elettra electron gun.

  5. Optimizing RF gun cavity geometry within an automated injector design system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alicia Hofler ,Pavel Evtushenko

    2011-03-28

    RF guns play an integral role in the success of several light sources around the world, and properly designed and optimized cw superconducting RF (SRF) guns can provide a path to higher average brightness. As the need for these guns grows, it is important to have automated optimization software tools that vary the geometry of the gun cavity as part of the injector design process. This will allow designers to improve existing designs for present installations, extend the utility of these guns to other applications, and develop new designs. An evolutionary algorithm (EA) based system can provide this capability becausemore » EAs can search in parallel a large parameter space (often non-linear) and in a relatively short time identify promising regions of the space for more careful consideration. The injector designer can then evaluate more cavity design parameters during the injector optimization process against the beam performance requirements of the injector. This paper will describe an extension to the APISA software that allows the cavity geometry to be modified as part of the injector optimization and provide examples of its application to existing RF and SRF gun designs.« less

  6. Femtosecond-laser-driven photoelectron-gun for time-resolved cathodoluminescence measurement of GaN.

    PubMed

    Onuma, T; Kagamitani, Y; Hazu, K; Ishiguro, T; Fukuda, T; Chichibu, S F

    2012-04-01

    A rear-excitation femtosecond-laser-driven photoelectron gun (PE-gun) is developed for measuring time-resolved cathodoluminescence (TRCL) spectrum of wide bandgap materials and structures such as semiconductors and phosphors. The maximum quantum efficiency of a 20-nm-thick Au photocathode excited using a frequency-tripled Al(2)O(3):Ti laser under a rear-excitation configuration is 3.6×10(-6), which is a reasonable value for a PE-gun. When the distance between the front edge of the PE-gun and the observation point is 10 mm, the narrowest electron-beam (e-beam) diameter is 19 μm, which corresponds to one tenth of the laser-beam diameter and is comparable to the initial e-beam diameter of a typical W hair-pin filament of thermionic electron-gun. From the results of TRCL measurements on the freestanding GaN grown by the ammonothermal method and a GaN homoepitaxial film grown by metalorganic vapor phase epitaxy, overall response time for the present TRCL system is estimated to be 8 ps. The value is the same as that of time-resolved photoluminescence measurement using the same excitation laser pulses, meaning that the time-resolution is simply limited by the streak-camera, not by the PE-gun performance. The result of numerical simulation on the temporal e-beam broadening caused by the space-charge-effect suggests that the present PE-gun can be used as a pulsed e-beam source for spatio-time-resolved cathodoluminescence, when equipped in a scanning electron microscope. © 2012 American Institute of Physics

  7. Femtosecond-laser-driven photoelectron-gun for time-resolved cathodoluminescence measurement of GaN

    NASA Astrophysics Data System (ADS)

    Onuma, T.; Kagamitani, Y.; Hazu, K.; Ishiguro, T.; Fukuda, T.; Chichibu, S. F.

    2012-04-01

    A rear-excitation femtosecond-laser-driven photoelectron gun (PE-gun) is developed for measuring time-resolved cathodoluminescence (TRCL) spectrum of wide bandgap materials and structures such as semiconductors and phosphors. The maximum quantum efficiency of a 20-nm-thick Au photocathode excited using a frequency-tripled Al2O3:Ti laser under a rear-excitation configuration is 3.6×10-6, which is a reasonable value for a PE-gun. When the distance between the front edge of the PE-gun and the observation point is 10 mm, the narrowest electron-beam (e-beam) diameter is 19 μm, which corresponds to one tenth of the laser-beam diameter and is comparable to the initial e-beam diameter of a typical W hair-pin filament of thermionic electron-gun. From the results of TRCL measurements on the freestanding GaN grown by the ammonothermal method and a GaN homoepitaxial film grown by metalorganic vapor phase epitaxy, overall response time for the present TRCL system is estimated to be 8 ps. The value is the same as that of time-resolved photoluminescence measurement using the same excitation laser pulses, meaning that the time-resolution is simply limited by the streak-camera, not by the PE-gun performance. The result of numerical simulation on the temporal e-beam broadening caused by the space-charge-effect suggests that the present PE-gun can be used as a pulsed e-beam source for spatio-time-resolved cathodoluminescence, when equipped in a scanning electron microscope.

  8. The Use of a Solid State Analog Television Transmitter as a Superconducting Electron Gun Power Amplifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.G. Kulpin, K.J. Kleman, R.A. Legg

    2012-07-01

    A solid state analog television transmitter designed for 200 MHz operation is being commissioned as a radio frequency power amplifier on the Wisconsin superconducting electron gun cavity. The amplifier consists of three separate radio frequency power combiner cabinets and one monitor and control cabinet. The transmitter employs rugged field effect transistors built into one kilowatt drawers that are individually hot swappable at maximum continuous power output. The total combined power of the transmitter system is 33 kW at 200 MHz, output through a standard coaxial transmission line. A low level radio frequency system is employed to digitally synthesize the 200more » MHz signal and precisely control amplitude and phase.« less

  9. Novel radio-frequency gun structures for ultrafast relativistic electron diffraction.

    PubMed

    Musumeci, P; Faillace, L; Fukasawa, A; Moody, J T; O'Shea, B; Rosenzweig, J B; Scoby, C M

    2009-08-01

    Radio-frequency (RF) photoinjector-based relativistic ultrafast electron diffraction (UED) is a promising new technique that has the potential to probe structural changes at the atomic scale with sub-100 fs temporal resolution in a single shot. We analyze the limitations on the temporal and spatial resolution of this technique considering the operating parameters of a standard 1.6 cell RF gun (which is the RF photoinjector used for the first experimental tests of relativistic UED at Stanford Linear Accelerator Center; University of California, Los Angeles; Brookhaven National Laboratory), and study the possibility of employing novel RF structures to circumvent some of these limits.

  10. Simulation of electron beam formation and transport in a gas-filled electron-optical system with a plasma emitter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grishkov, A. A.; Kornilov, S. Yu., E-mail: kornilovsy@gmail.com; Rempe, N. G.

    2016-07-15

    The results of computer simulations of the electron-optical system of an electron gun with a plasma emitter are presented. The simulations are performed using the KOBRA3-INP, XOOPIC, and ANSYS codes. The results describe the electron beam formation and transport. The electron trajectories are analyzed. The mechanisms of gas influence on the energy inhomogeneity of the beam and its current in the regions of beam primary formation, acceleration, and transport are described. Recommendations for optimizing the electron-optical system with a plasma emitter are presented.

  11. Modification of anisotropic plasma diffusion via auxiliary electrons emitted by a carbon nanotubes-based electron gun in an electron cyclotron resonance ion source.

    PubMed

    Malferrari, L; Odorici, F; Veronese, G P; Rizzoli, R; Mascali, D; Celona, L; Gammino, S; Castro, G; Miracoli, R; Serafino, T

    2012-02-01

    The diffusion mechanism in magnetized plasmas is a largely debated issue. A short circuit model was proposed by Simon, assuming fluxes of lost particles along the axial (electrons) and radial (ions) directions which can be compensated, to preserve the quasi-neutrality, by currents flowing throughout the conducting plasma chamber walls. We hereby propose a new method to modify Simon's currents via electrons injected by a carbon nanotubes-based electron gun. We found this improves the source performances, increasing the output current for several charge states. The method is especially sensitive to the pumping frequency. Output currents for given charge states, at different auxiliary electron currents, will be reported in the paper and the influence of the frequency tuning on the compensation mechanism will be discussed.

  12. Gun Control, Gun Ownership, and Suicide Prevention.

    ERIC Educational Resources Information Center

    Lester, David

    1988-01-01

    Explored relationship between the extent of gun ownership and the strictness of gun control laws to suicide and homicide rates in the nine major geographic regions of the United States. Found gun ownership, rather than the strictness of gun control laws, was the strongest correlate of the rates of suicide and homicide by guns. (Author)

  13. High quality single shot ultrafast MeV electron diffraction from a photocathode radio-frequency gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Feichao; Liu, Shengguang; Zhu, Pengfei

    2014-08-15

    A compact ultrafast electron diffractometer, consisting of an s-band 1.6 cell photocathode radio-frequency gun, a multi-function changeable sample chamber, and a sensitive relativistic electron detector, was built at Shanghai Jiao Tong University. High-quality single-shot transmission electron diffraction patterns have been recorded by scattering 2.5 MeV electrons off single crystalline gold and polycrystalline aluminum samples. The high quality diffraction pattern indicates an excellent spatial resolution, with the ratio of the diffraction ring radius over the ring rms width beyond 10. The electron pulse width is estimated to be about 300 fs. The high temporal and spatial resolution may open new opportunities inmore » various areas of sciences.« less

  14. High quality single shot ultrafast MeV electron diffraction from a photocathode radio-frequency gun.

    PubMed

    Fu, Feichao; Liu, Shengguang; Zhu, Pengfei; Xiang, Dao; Zhang, Jie; Cao, Jianming

    2014-08-01

    A compact ultrafast electron diffractometer, consisting of an s-band 1.6 cell photocathode radio-frequency gun, a multi-function changeable sample chamber, and a sensitive relativistic electron detector, was built at Shanghai Jiao Tong University. High-quality single-shot transmission electron diffraction patterns have been recorded by scattering 2.5 MeV electrons off single crystalline gold and polycrystalline aluminum samples. The high quality diffraction pattern indicates an excellent spatial resolution, with the ratio of the diffraction ring radius over the ring rms width beyond 10. The electron pulse width is estimated to be about 300 fs. The high temporal and spatial resolution may open new opportunities in various areas of sciences.

  15. Public Support for Gun Violence Prevention Policies Among Gun Owners and Non-Gun Owners in 2017.

    PubMed

    Barry, Colleen L; Webster, Daniel W; Stone, Elizabeth; Crifasi, Cassandra K; Vernick, Jon S; McGinty, Emma E

    2018-07-01

    To compare public support for 24 different gun policies between gun owners and non-gun owners in 2017. We fielded a national public opinion survey in January 2017 using an online panel to measure US adults' support for 24 gun policies. We compared support among gun owners and non-gun owners. For 23 of the 24 policies examined, most respondents supported restricting or regulating gun ownership. Only 8 of 24 policies had greater than a 10-point support gap between gun owners and non-gun owners. Policies with high public support and minimal support gaps by gun ownership status included universal background checks, greater accountability for licensed gun dealers unable to account for their inventory, higher safety training standards for concealed carry permit holders, improved reporting of records related to mental illness for background checks, gun prohibitions for persons subject to temporary domestic violence restraining orders, and gun violence restraining orders. Public Health Implications. Although there are important areas where Americans disagree on guns, large majorities of both gun owners and non-gun owners strongly support measures to strengthen US gun laws.

  16. A new evaluation method of electron optical performance of high beam current probe forming systems.

    PubMed

    Fujita, Shin; Shimoyama, Hiroshi

    2005-10-01

    A new numerical simulation method is presented for the electron optical property analysis of probe forming systems with point cathode guns such as cold field emitters and the Schottky emitters. It has long been recognized that the gun aberrations are important parameters to be considered since the intrinsically high brightness of the point cathode gun is reduced due to its spherical aberration. The simulation method can evaluate the 'threshold beam current I(th)' above which the apparent brightness starts to decrease from the intrinsic value. It is found that the threshold depends on the 'electron gun focal length' as well as on the spherical aberration of the gun. Formulas are presented to estimate the brightness reduction as a function of the beam current. The gun brightness reduction must be included when the probe property (the relation between the beam current l(b) and the probe size on the sample, d) of the entire electron optical column is evaluated. Formulas that explicitly consider the gun aberrations into account are presented. It is shown that the probe property curve consists of three segments in the order of increasing beam current: (i) the constant probe size region, (ii) the brightness limited region where the probe size increases as d approximately I(b)(3/8), and (iii) the angular current intensity limited region in which the beam size increases rapidly as d approximately I(b)(3/2). Some strategies are suggested to increase the threshold beam current and to extend the effective beam current range of the point cathode gun into micro ampere regime.

  17. Adaptive electron beam shaping using a photoemission gun and spatial light modulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxson, Jared; Lee, Hyeri; Bartnik, Adam C.

    The need for precisely defined beam shapes in photoelectron sources has been well established. In this paper, we use a spatial light modulator and simple shaping algorithm to create arbitrary, detailed transverse laser shapes with high fidelity. We transmit this shaped laser to the photocathode of a high voltage dc gun. Using beam currents where space charge is negligible, and using an imaging solenoid and fluorescent viewscreen, we show that the resultant beam shape preserves these detailed features with similar fidelity. Next, instead of transmitting a shaped laser profile, we use an active feedback on the unshaped electron beam imagemore » to create equally accurate and detailed shapes. We demonstrate that this electron beam feedback has the added advantage of correcting for electron optical aberrations, yielding shapes without skew. The method may serve to provide precisely defined electron beams for low current target experiments, space-charge dominated beam commissioning, as well as for online adaptive correction of photocathode quantum efficiency degradation.« less

  18. Adaptive electron beam shaping using a photoemission gun and spatial light modulator

    NASA Astrophysics Data System (ADS)

    Maxson, Jared; Lee, Hyeri; Bartnik, Adam C.; Kiefer, Jacob; Bazarov, Ivan

    2015-02-01

    The need for precisely defined beam shapes in photoelectron sources has been well established. In this paper, we use a spatial light modulator and simple shaping algorithm to create arbitrary, detailed transverse laser shapes with high fidelity. We transmit this shaped laser to the photocathode of a high voltage dc gun. Using beam currents where space charge is negligible, and using an imaging solenoid and fluorescent viewscreen, we show that the resultant beam shape preserves these detailed features with similar fidelity. Next, instead of transmitting a shaped laser profile, we use an active feedback on the unshaped electron beam image to create equally accurate and detailed shapes. We demonstrate that this electron beam feedback has the added advantage of correcting for electron optical aberrations, yielding shapes without skew. The method may serve to provide precisely defined electron beams for low current target experiments, space-charge dominated beam commissioning, as well as for online adaptive correction of photocathode quantum efficiency degradation.

  19. Adaptive electron beam shaping using a photoemission gun and spatial light modulator

    DOE PAGES

    Maxson, Jared; Lee, Hyeri; Bartnik, Adam C.; ...

    2015-02-01

    The need for precisely defined beam shapes in photoelectron sources has been well established. In this paper, we use a spatial light modulator and simple shaping algorithm to create arbitrary, detailed transverse laser shapes with high fidelity. We transmit this shaped laser to the photocathode of a high voltage dc gun. Using beam currents where space charge is negligible, and using an imaging solenoid and fluorescent viewscreen, we show that the resultant beam shape preserves these detailed features with similar fidelity. Next, instead of transmitting a shaped laser profile, we use an active feedback on the unshaped electron beam imagemore » to create equally accurate and detailed shapes. We demonstrate that this electron beam feedback has the added advantage of correcting for electron optical aberrations, yielding shapes without skew. The method may serve to provide precisely defined electron beams for low current target experiments, space-charge dominated beam commissioning, as well as for online adaptive correction of photocathode quantum efficiency degradation.« less

  20. DC High Voltage Conditioning of Photoemission Guns at Jefferson Lab FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez-Garcia, C.; Benson, S. V.; Biallas, G.

    2009-08-04

    DC high voltage photoemission electron guns with GaAs photocathodes have been used to produce polarized electron beams for nuclear physics experiments for about 3 decades with great success. In the late 1990s, Jefferson Lab adopted this gun technology for a free electron laser (FEL), but to assist with high bunch charge operation, considerably higher bias voltage is required compared to the photoguns used at the Jefferson Lab Continuous Electron Beam Accelerator Facility. The FEL gun has been conditioned above 400 kV several times, albeit encountering non-trivial challenges with ceramic insulators and field emission from electrodes. Recently, high voltage processing withmore » krypton gas was employed to process very stubborn field emitters. This work presents a summary of the high voltage techniques used to high voltage condition the Jefferson Lab FEL photoemission gun.« less

  1. Whose guns are stolen? The epidemiology of Gun theft victims.

    PubMed

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2017-12-01

    Gun theft is an important source of guns used by criminals. Yet no empirical work has focused on the characteristics of gun owners that distinguish those who have had their guns stolen from those who have not. In this study, we examine the demographics and behavioral characteristics of gun owners who report having had a gun stolen. Data come from a nationally representative probability-based online survey conducted in April 2015, with a linked follow-up survey in November 2015 that asked gun owners about any theft of their guns in the past 5 years. Of 1,604 gun-owning respondents, 2.4% (95% CI 1.6,3.6) reported that one or more guns had been stolen, with a mean number of guns stolen per theft of 1.5 (95% CI 1.0,2.0]. Risk factors for having a gun stolen were owning 6 or more guns, owning guns for protection, carrying a gun in the past month, storing guns unsafely, and living in the South region of the United States. The South accounts for 37% of US households, 43% of gun owners, and two-thirds of all gun thefts. We estimate that there are approximately 250,000 gun theft incidents per year, with about 380,000 guns stolen. We find that certain types of gun owners-who own many guns, who carry guns, and who do not store guns safely-are at higher risk to have their guns stolen. Tracing data show that states in the South are exporters of crime guns used in other states. Our survey results find that the majority of guns stolen in the US come from the South.

  2. Systems and methods for coating conduit interior surfaces utilizing a thermal spray gun with extension arm

    DOEpatents

    Moore, Karen A.; Zatorski, Raymond A.

    2005-07-12

    Systems and methods for applying a coating to an interior surface of a conduit. In one embodiment, a spray gun configured to apply a coating is attached to an extension arm which may be inserted into the bore of a pipe. The spray gun may be a thermal spray gun adapted to apply a powder coating. An evacuation system may be used to provide a volume area of reduced air pressure for drawing overspray out of the pipe interior during coating. The extension arm as well as the spray gun may be cooled to maintain a consistent temperature in the system, allowing for more consistent coating.

  3. Improved DC Gun and Insulator Assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neubauer, Michael

    Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diametermore » ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.« less

  4. Keeping Naval Guns Ready

    DTIC Science & Technology

    2016-03-01

    Keeping Naval Guns Ready David L. Rogers Rogers is the Deputy Department Head, Systems Integration Department, Naval Surface Warfare Center Indian...maritime routes and the global economy. This protection depends on keeping these forward naval ships ready, par- ticularly their guns and ammunition...the weapons of choice for counter- ing a multitude of threats. That gun readiness is assured with responsive technical support. It is done fast, and

  5. Self-contained hot-hollow cathode gun source assembly

    DOEpatents

    Zeren, Joseph D.

    1986-01-01

    A self-contained hot-hollow cathode gun source assembly for use in a vacuum chamber includes a crucible block having a hot-hollow cathode gun mounted underneath and providing a hole for the magnetic deflection of the ion/electron beam into a crucible on top the block.

  6. Self-contained hot-hollow cathode gun source assembly

    DOEpatents

    Zeren, J.D.

    1984-08-01

    A self-contained hot-hollow cathode gun source assembly for use in a vacuum chamber includes a crucible block having a hot-hollow cathode gun mounted underneath and providing a hole for the magnetic deflection of the ion/electron beam into a crucible on top the block.

  7. Characterization of the C-2W Plasma Guns

    NASA Astrophysics Data System (ADS)

    Dubois, Ami; Sokolov, Vladimir; Korepanov, Sergey; Osin, Dima; Player, Gabriel; TAE Team

    2017-10-01

    Previous use of coaxial arc discharge plasma guns on the C-2U device exhibited great success in plasma stabilization and improved confinement. On the C-2W experiment, arc discharge plasma guns will again be used to facilitate the electrical connection between the plasma core and the divertor electrodes in order to maintain the electrode edge biasing and induce E x B shear to control plasma rotation. Each plasma gun contains an internal solenoid used to shape the plasma stream. Characterization of electron density (ne) , electron temperature (Te) , floating potential (Vf) , and total plasma flux in an arc discharge lasting 6 ms without the internal solenoid are presented. A Langmuir probe located 27 cm axially outside of the plasma gun anode measures a bell-like radial ne profile with peak ne 1018 m-3 and Te 2 - 10 eV. Observed spectral lines of impurity ions provide an estimate of Te, and Balmer series line ratios of the main ion component are used to evaluate ne at both the probe location and near the plasma gun anode. A calorimeter measures the plasma flux to be constant and equivalent to 1 kA.

  8. Spindt cold cathode electron gun development program

    NASA Technical Reports Server (NTRS)

    Spindt, C. A.

    1983-01-01

    A thin film field emission cathode array and an electron gun based on this emitter array are summarized. Fabricating state of the art cathodes for testing at NASA and NRL, advancing the fabrication technology, developing wedge shaped emitters, and performing emission tests are covered. An anistropic dry etching process (reactive ion beam etching) developed that leads to increasing the packing density of the emitter tips to about 5 x 10 to the 6th power/square cm. Tests with small arrays of emitter tips having about 10 tips has demonstrated current densities of over 100 A/sq cm. Several times using cathodes having a packing density of 1.25 x 10 to the 6th power tips/sq cm. Indications are that the higher packing density achievable with the dry etch process may extend this capability to the 500 A/sq cm range and beyond. The wedge emitter geometry was developed and shown to produce emission. This geometry can (in principle) extend the current density capability of the cathodes beyond the 500 A/sq cm level. An emission microscope was built and tested for use with the cathodes.

  9. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties

    PubMed Central

    Swanson, Jeffrey W.; Easter, Michele M.; Robertson, Allison G.; Swartz, Marvin S.; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-01-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. PMID:27269024

  10. Effect of RF Gradient upon the Performance of the Wisconsin SRF Electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosch, Robert; Legg, Robert A.

    2013-12-01

    The performance of the Wisconsin 200-MHz SRF electron gun is simulated for several values of the RF gradient. Bunches with charge of 200 pC are modeled for the case where emittance compensation is completed during post-acceleration to 85 MeV in a TESLA module. We first perform simulations in which the initial bunch radius is optimal for the design gradient of 41 MV/m. We then optimize the radius as a function of RF gradient to improve the performance for low gradients.

  11. Integrated numerical modeling of a laser gun injector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, H.; Benson, S.; Bisognano, J.

    1993-06-01

    CEBAF is planning to incorporate a laser gun injector into the linac front end as a high-charge cw source for a high-power free electron laser and nuclear physics. This injector consists of a DC laser gun, a buncher, a cryounit and a chicane. The performance of the injector is predicted based on integrated numerical modeling using POISSON, SUPERFISH and PARMELA. The point-by-point method incorporated into PARMELA by McDonald is chosen for space charge treatment. The concept of ``conditioning for final bunching`` is employed to vary several crucial parameters of the system for achieving highest peak current while maintaining low emittancemore » and low energy spread. Extensive parameter variation studies show that the design will perform beyond the specifications for FEL operations aimed at industrial applications and fundamental scientific research. The calculation also shows that the injector will perform as an extremely bright cw electron source.« less

  12. Gun Play

    ERIC Educational Resources Information Center

    Mechling, Jay

    2008-01-01

    Biology and the particular gun culture of the United States come together to explain the persistent and powerful attraction of American boys to both real guns and toy guns. The 1990s saw adults begin to conflate "the gun problem" with "the boy problem," sparking attempts (largely failed) to banish toy guns from homes and…

  13. Advanced Gun System (AGS) Dynamic Characterization: Modal Test and Analysis, High-Frequency Analysis.

    DTIC Science & Technology

    1999-12-01

    frequency data (to 10 kHz) in the AGS test. 3.2 High-Frequency Damping Determination by Wavelet Transform. The continuous wavelet transform (CWT...ARMY RESEARCH LABORATORY MmOSm Hi Advanced Gun System ( AGS ) Dynamic Characterization: Modal Test and Analysis, High-Frequency Analysis by Morris...this report when it is no longer needed. Do not return it to the originator. ERRATA SHEET re: ARL-TR-2138 "Advanced Gun System ( AGS ) Dynamic

  14. Initial Beam Dynamics Simulations of a High-Average-Current Field-Emission Electron Source in a Superconducting RadioFrequency Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohsen, O.; Gonin, I.; Kephart, R.

    High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to formmore » $$\\sim$$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.« less

  15. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties.

    PubMed

    Swanson, Jeffrey W; Easter, Michele M; Robertson, Allison G; Swartz, Marvin S; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-06-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. Project HOPE—The People-to-People Health Foundation, Inc.

  16. Plasma-filled diode based on the coaxial gun

    NASA Astrophysics Data System (ADS)

    Zherlitsyn, A. A.; Kovalchuk, B. M.; Pedin, N. N.

    2012-10-01

    The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of ≥1 MeV at the current of ≈100 kA was obtained in the experiments with a plasma-filled diode. The energy of ≈5 kJ with the peak power of ≥100 GW dissipated in the diode.

  17. Plasma-filled diode based on the coaxial gun.

    PubMed

    Zherlitsyn, A A; Kovalchuk, B M; Pedin, N N

    2012-10-01

    The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of ≥1 MeV at the current of ≈100 kA was obtained in the experiments with a plasma-filled diode. The energy of ≈5 kJ with the peak power of ≥100 GW dissipated in the diode.

  18. Gridded thermionic gun and integral superconducting ballistic bunch compression cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schultheiss, Thomas

    Electron-Ion colliders such as the Medium energy Electron Ion Collider (MEIC) being developed by JLAB require high current electrons with low energy spread for electron cooling of the collider ring. Accelerator techniques for improving bunch charge, average current, emittance, and energy spread are required for Energy Recovery Linacs (ERLs) and Circulator Rings (CR) for next generation colliders for nuclear physics experiments. Example candidates include thermionic-cathode electron guns with RF accelerating structures. Thermionic cathodes are known to produce high currents and have excellent lifetime. The success of the IR and THz Free-Electron Laser (FEL) designed and installed by Advanced Energy Systemsmore » at the Fritz Haber Institute (FHI) of the Max Planck Society in Berlin [1,2] demonstrates that gridded thermionic cathodes and rf systems be considered for next generation collider technology. In Phase 1 Advanced Energy Systems (AES) developed and analyzed a design concept using a superconducting cavity pair and gridded thermionic cathode. Analysis included Beam Dynamics and thermal analysis to show that a design of this type is feasible. The latest design goals for the MEIC electron cooler were for electron bunches of 420 pC at a frequency of 952.6 MHz with a magnetic field on the cathode of 2kG. This field magnetizes the beam imparting angular momentum that provides for helical motion of the electrons in the cooling solenoid. The helical motion increases the interaction time and improves the cooling efficiency. A coil positioned around the cathode providing 2kG field was developed. Beam dynamics simulations were run to develop the particle dynamics near the cathode and grid. Lloyd Young added capability to Tstep to include space charge effects between two plates and include image charge effects from the grid. He also added new pepper-pot geometry capability to account for honeycomb grids. These additions were used to develop the beam dynamics for this

  19. Geometries and focal properties of two electron-lens systems useful in low-energy electron or ion scattering

    NASA Technical Reports Server (NTRS)

    Chutjian, A.

    1979-01-01

    Geometries and focal properties are given for two types of electron-lens system commonly needed in electron scattering. One is an electron gun that focuses electrons from a thermionic emitter onto a fixed point (target) over a wide range of final energies. The other is an electron analyzer system that focuses scattered electrons of variable energy onto a fixed position (e.g., the entrance plane of an analyzer) at fixed energy with a zero final beam angle. Analyzer-system focusing properties are given for superelastically, elastically, and inelastically scattered electrons. Computer calculations incorporating recent accurate tube-lens focal properties are used to compute lens voltages, locations and diameters of all pupils and windows, filling factors, and asymptotic rays throughout each lens system. Focus voltages as a function of electron energy and energy change are given, and limits of operation of each system discussed. Both lens systems have been in routine use for several years, and good agreement has been consistently found between calculated and operating lens voltages.

  20. Toroid Joining Gun. [thermoplastic welding system using induction heating

    NASA Technical Reports Server (NTRS)

    Buckley, J. D.; Fox, R. L.; Swaim, R J.

    1985-01-01

    The Toroid Joining Gun is a low cost, self-contained, portable low powered (100-400 watts) thermoplastic welding system developed at Langley Research Center for joining plastic and composite parts using an induction heating technique. The device developed for use in the fabrication of large space sructures (LSST Program) can be used in any atmosphere or in a vacuum. Components can be joined in situ, whether on earth or on a space platform. The expanded application of this welding gun is in the joining of thermoplastic composites, thermosetting composites, metals, and combinations of these materials. Its low-power requirements, light weight, rapid response, low cost, portability, and effective joining make it a candidate for solving many varied and unique bonding tasks.

  1. Gun Shows and Gun Violence: Fatally Flawed Study Yields Misleading Results

    PubMed Central

    Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A.

    2010-01-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled “The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas” outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors’ prior research. The study should not be used as evidence in formulating gun policy. PMID:20724672

  2. Gun shows and gun violence: fatally flawed study yields misleading results.

    PubMed

    Wintemute, Garen J; Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A

    2010-10-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled "The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas" outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors' prior research. The study should not be used as evidence in formulating gun policy.

  3. Encyclopedia of Gun Control and Gun Rights.

    ERIC Educational Resources Information Center

    Utter, Glenn H.

    This reference volume provides information on gun control and gun rights, including resources on the debate surrounding the Second Amendment and individuals and organizations focused on gun issues, along with statutes, court cases, events, and publications surrounding this current topic. Highlighted are the important organizations and their…

  4. WE-G-17A-08: Electron Gun Operation for in Line MRI-Linac Configurations: An Assessment of Beam Fidelity and Recovery Techniques for Different SIDs and Magnetic Field Strengths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whelan, B; Keall, P; Ingham Institute, Liverpool, Aus

    Purpose: To test the functionality of medical electron guns within the fringe field of a purpose built superconducting MRI magnet, and to test different recovery techniques for a variety of imaging field strengths and SIDs. Methods: Three different electron guns were simulated using Finite Element Modelling; a standard diode gun, a standard triode gun, and a novel diode gun designed to operate within parallel magnetic fields. The approximate working regime of each gun was established by assessing exit current in constant magnetic fields of varying strength and defining ‘working’ as less than 10% change in injection current. Next, the 1.0Tmore » MRI magnet was simulated within Comsol Multiphysics. The coil currents in this model were also scaled to produce field strengths of .5, 1, 1.5 and 3T. Various magnetic shield configurations were simulated, varying the SID from 800 to 1300mm. The average magnetic field within the gun region was assessed together with the distortion in the imaging volume - greater than 150uT distortion was considered unacceptable. Results: The conventional guns functioned in fields of less than 7.5mT. Conversely, the redesigned diode required fields greater than .1T to function correctly. Magnetic shielding was feasible for SIDS of greater than 1000mm for field strengths of .5T and 1T, and 1100mm for 1.5 and 3.0T. Beyond these limits shielding resulted in unacceptable MRI distortion. In contrast, the redesigned diode could perform acceptably for SIDs of less than 812, 896, 931, and 974mm for imaging strengths of 0.5, 1.0, 1.5, 3.0T. Conclusions: For in-line MRIlinac configurations where the electron gun is operating in low field regions, shielding is a straight forward option. However, as magnetic field strength increases and the SID is reduced, shielding results in too great a distortion in the MRI and redesigning the electron optics is the preferable solution. The authors would like to acknowledge funding from the National Health and

  5. Planning Support for Maintenance and Overhaul of Gun Weapon Systems

    DTIC Science & Technology

    1981-05-01

    13 (shielded twin) gun mounts are targeted to receive ORDALTs 9335 and 9409. Sixty-seven ship hulls are involved in the program, for a total of 147...gun mounts (excluding four training mounts ). Seventy-three Mod 0 and seventy-four Mod 13 gun mounts are included in the program, for an estimated total ...of gun mounts included in the GWSIP. Each mount will receive one amplifier ORDALT, for a. a total of 147, and two upgraded oscillating assemblies

  6. Electron gun for a multiple beam klystron with magnetic compression of the electron beams

    DOEpatents

    Ives, R. Lawrence; Tran, Hien T; Bui, Thuc; Attarian, Adam; Tallis, William; David, John; Forstall, Virginia; Andujar, Cynthia; Blach, Noah T; Brown, David B; Gadson, Sean E; Kiley, Erin M; Read, Michael

    2013-10-01

    A multi-beam electron gun provides a plurality N of cathode assemblies comprising a cathode, anode, and focus electrode, each cathode assembly having a local cathode axis and also a central cathode point defined by the intersection of the local cathode axis with the emitting surface of the cathode. Each cathode is arranged with its central point positioned in a plane orthogonal to a device central axis, with each cathode central point an equal distance from the device axis and with an included angle of 360/N between each cathode central point. The local axis of each cathode has a cathode divergence angle with respect to the central axis which is set such that the diverging magnetic field from a solenoidal coil is less than 5 degrees with respect to the projection of the local cathode axis onto a cathode reference plane formed by the device axis and the central cathode point, and the local axis of each cathode is also set such that the angle formed between the cathode reference plane and the local cathode axis results in minimum spiraling in the path of the electron beams in a homogenous magnetic field region of the solenoidal field generator.

  7. Experimental investigation of a 1 kA/cm² sheet beam plasma cathode electron gun.

    PubMed

    Kumar, Niraj; Pal, Udit Narayan; Pal, Dharmendra Kumar; Prajesh, Rahul; Prakash, Ram

    2015-01-01

    In this paper, a cold cathode based sheet-beam plasma cathode electron gun is reported with achieved sheet-beam current density ∼1 kA/cm(2) from pseudospark based argon plasma for pulse length of ∼200 ns in a single shot experiment. For the qualitative assessment of the sheet-beam, an arrangement of three isolated metallic-sheets is proposed. The actual shape and size of the sheet-electron-beam are obtained through a non-conventional method by proposing a dielectric charging technique and scanning electron microscope based imaging. As distinct from the earlier developed sheet beam sources, the generated sheet-beam has been propagated more than 190 mm distance in a drift space region maintaining sheet structure without assistance of any external magnetic field.

  8. Design and development of indirectly heated solid cathode for strip type electron gun.

    PubMed

    Maiti, Namita; Mukherjee, S; Kumar, Bhunesh; Barve, U D; Suryawanshi, V B; Das, A K

    2010-01-01

    Design analysis of a high power indirectly heated solid cathode (for a 200 kW, 45 kV, and 270 degrees bent strip type electron gun) has been presented. The design approach consists of simulation followed by extensive experimentation with different cathode configurations. The preferred cathode is of trapezoidal section (8 x 4 x 2 mm(3)) with an emitting area of 110 x 4 mm(2) made up of tantalum operating at about 2500 K. The solid cathode at the operating temperature of 2500 K generated a well defined electron beam. Electromagnetic and thermomechanical simulation is used to optimize the shape of the beam. Thermal modeling has also been used to analyze the temperature and stress distribution on the electrodes. The simulation results are validated by experimental measurement.

  9. Beam characterisation of the KIRAMS electron microbeam system.

    PubMed

    Sun, G M; Kim, E H; Song, K B; Jang, M

    2006-01-01

    An electron microbeam system has been installed at the Korea Institute of Radiological and Medical Sciences (KIRAMS) for use in radiation biology studies. The electron beam is produced from a commercial electron gun, and the beam size is defined by a 5 microm diameter pinhole. Beam energy can be varied in the range of 1-100 keV, covering a range of linear energy transfer from 0.4 to 12.1 keV microm-1. The micrometer-sized electron beam selectively irradiates cells cultured in a Mylar-bottomed dish. The positioning of target cells one by one onto the beam exit is automated, as is beam shooting. The electron beam entering the target cells has been calibrated using a Passivated Implanted Planar Silicon (PIPS) detector. This paper describes the KIRAMS microbeam cell irradiation system and its beam characteristics.

  10. Electron beam deflection control system of a welding and surface modification installation

    NASA Astrophysics Data System (ADS)

    Koleva, E.; Dzharov, V.; Gerasimov, V.; Tsvetkov, K.; Mladenov, G.

    2018-03-01

    In the present work, we examined the patterns of the electron beam motion when controlling the transverse with respect to the axis of the beam homogeneous magnetic field created by the coils of the deflection system the electron gun. During electron beam processes, the beam motion is determined the process type (welding, surface modification, etc.), the technological mode, the design dimensions of the electron gun and the shape of the processed samples. The electron beam motion is defined by the cumulative action of two cosine-like control signals generated by a functional generator. The signal control is related to changing the amplitudes, frequencies and phases (phase differences) of the generated voltages. We realized the motion control by applying a graphical user interface developed by us and an Arduino Uno programmable microcontroller. The signals generated were calibrated using experimental data from the available functional generator. The free and precise motion on arbitrary trajectories determines the possible applications of an electron beam process to carrying out various scientific research tasks in material processing.

  11. State Gun Law Environment and Youth Gun Carrying in the United States.

    PubMed

    Xuan, Ziming; Hemenway, David

    2015-11-01

    Gun violence and injuries pose a substantial threat to children and youth in the United States. Existing evidence points to the need for interventions and policies for keeping guns out of the hands of children and youth. (1) To examine the association between state gun law environment and youth gun carrying in the United States, and (2) to determine whether adult gun ownership mediates this association. This was a repeated cross-sectional observational study design with 3 years of data on youth gun carrying from US states. The Youth Risk Behavior Survey comprises data of representative samples of students in grades 9 to 12 from biennial years of 2007, 2009, and 2011. We hypothesized that states with more restrictive gun laws have lower rates of youth gun carrying, and this association is mediated by adult gun ownership. State gun law environment as measured by state gun law score. Youth gun carrying was defined as having carried a gun on at least 1 day during the 30 days before the survey. In the fully adjusted model, a 10-point increase in the state gun law score, which represented a more restrictive gun law environment, was associated with a 9% decrease in the odds of youth gun carrying (adjusted odds ratio [AOR], 0.91 [95% CI, 0.86-0.96]). Adult gun ownership mediated the association between state gun law score and youth gun carrying (AOR, 0.94 [ 95% CI, 0.86-1.01], with 29% attenuation of the regression coefficient from -0.09 to -0.07 based on bootstrap resampling). More restrictive overall gun control policies are associated with a reduced likelihood of youth gun carrying. These findings are relevant to gun policy debates about the critical importance of strengthening overall gun law environment to prevent youth gun carrying.

  12. Gun threats against and self-defense gun use by California adolescents.

    PubMed

    Hemenway, David; Miller, Matthew

    2004-04-01

    To assess hostile gun use against and self-defense gun use by adolescents. We use random-digit-dial telephone survey data collected from approximately 5800 California adolescents, aged 12 through 17 years, between November 1, 2000, and October 31, 2001. The prevalence and correlates of reported hostile gun use against and self-defense gun use by adolescents, as well as qualitative information about these 2 types of gun uses. Correlates include age, sex, ethnicity, smoking, alcoholic binge drinking, threatening others, parents knowing their adolescent's whereabouts in the afternoon after school, attending school, area urbanization and poverty level, and living in a household with a gun. Approximately 4% of the adolescents reported ever having been threatened with a gun; only 0.3% reported using a gun in self-defense. Boys, smokers, adolescents who threatened others, and adolescents whose parents knew little about their whereabouts in the afternoon after school were more likely to report being threatened with a gun. Most episodes of self-defense gun use seem to be hostile interactions between adolescents with weapons. Far more California adolescents are threatened with a gun than use a gun in self-defense. Self-defense gun use is rare; many of the reported self-defense gun uses seem to be armed confrontations.

  13. RF Design of the LCLS Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C

    Final dimensions for the LCLS RF gun are described. This gun, referred to as the LCLS gun, is a modified version of the UCLA/BNL/SLAC 1.6 cell S-Band RF gun [1], referred to as the prototype gun. The changes include a larger mode separation (15 MHz for the LCLS gun vs. 3.5 MHz for the prototype gun), a larger radius at the iris between the 2 cells, a reduced surface field on the curvature of the iris between the two cells, Z power coupling, increased cooling channels for operation at 120 Hz, dual rf feed, deformation tuning of the full cell,more » and field probes in both cells. Temporal shaping of the klystron pulse, to reduce the average power dissipated in the gun, has also been adopted. By increasing the mode separation, the amplitude of the 0-mode electric field on the cathode decreases from 10% of the peak on axis field for the prototype gun to less than 3% for the LCLS gun for the steady state fields. Beam performance is improved as shown by the PARMELA simulations. The gun should be designed to accept a future load lock system. Modifications follow the recommendations of our RF review committee [2]. Files and reference documents are compiled in Section IV.« less

  14. A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes.

    PubMed

    Kumar, Niraj; Pal, Dharmendra Kumar; Jadon, Arvind Singh; Pal, Udit Narayan; Rahaman, Hasibur; Prakash, Ram

    2016-03-01

    In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electron beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.

  15. Two-stage plasma gun based on a gas discharge with a self-heating hollow emitter.

    PubMed

    Vizir, A V; Tyunkov, A V; Shandrikov, M V; Oks, E M

    2010-02-01

    The paper presents the results of tests of a new compact two-stage bulk gas plasma gun. The plasma gun is based on a nonself-sustained gas discharge with an electron emitter based on a discharge with a self-heating hollow cathode. The operating characteristics of the plasma gun are investigated. The discharge system makes it possible to produce uniform and stable gas plasma in the dc mode with a plasma density up to 3x10(9) cm(-3) at an operating gas pressure in the vacuum chamber of less than 2x10(-2) Pa. The device features high power efficiency, design simplicity, and compactness.

  16. Method for Designing Electronic Assemblies without Potting for Gun Launched Applications Through the Use of Additive Manufacturing

    DTIC Science & Technology

    2016-12-01

    easily would be preferred. Many studies have been conducted to model the effects of potting materials on PCBs and their components: two such studies ...catch (SCAT) gun Guidance electronics On -board recorder (OBR) Precision guided munition (PGM) 16. SECURITY CLASSIFICATION OF: 17... On -board Recorder 2 Initial Method - Modeling Assumptions 2 Initial Method - Parts, Instances, and Simplifications in the Model 3 Initial Method

  17. Electron gun with a transmission photocathode for the Joint Institute for Nuclear Research photoinjector

    NASA Astrophysics Data System (ADS)

    Balalykin, N. I.; Minashkin, V. F.; Nozdrin, M. A.; Shirkov, G. D.; Zelenogorskii, V. V.; Gacheva, E. I.; Potemkin, A. K.; Huran, J.

    2017-10-01

    Photocathode electron guns are key to the generation of high-quality electron bunches, which are currently the primary source of electrons for linear electron accelerators. The photogun test bench built at the Joint Institute for Nuclear Research (JINR) is currently being used to further develop the hollow (backside irradiated) photocathode concept. A major achievement was the replacement of the hollow photocathode by a technologically more feasible transmission photocathode made from a metal mesh that serves as a substrate for films of various photomaterials. A number of thin-film cathodes on quartz glass substrates are fabricated by photolithography. The vectorial photoeffect (related to the surface-normal component of the wave electric field) is observed and found to significantly affect the quantum efficiency. The dependence of the quantum efficiency of diamond-like carbon photocathodes on the manufacturing technology is investigated. The Rutherford backscattering and elastic recoil detection techniques are combined to carry out an elemental analysis of the films. An estimate of the emittance of a 400 pC electron beam is obtained using the cross-section method.

  18. Dynamic optical modulation of an electron beam on a photocathode RF gun: Toward intensity-modulated radiation therapy (IMRT)

    NASA Astrophysics Data System (ADS)

    Kondoh, Takafumi; Kashima, Hiroaki; Yang, Jinfeng; Yoshida, Yoichi; Tagawa, Seiichi

    2008-10-01

    In intensity-modulated radiation therapy (IMRT), the aim is to deliver reduced doses of radiation to normal tissue. As a step toward IMRT, we examined dynamic optical modulation of an electron beam produced by a photocathode RF gun. Images on photomasks were transferred onto a photocathode by relay imaging. The resulting beam was controlled by a remote mirror. The modulated electron beam maintained its shape on acceleration, had a fine spatial resolution, and could be moved dynamically by optical methods.

  19. Magnetic induction system for two-stage gun projectile velocity measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moody, R L; Konrad, C H

    1984-05-01

    A magnetic induction technique for measuring projectile velocities has been implemented on Sandia's two-stage light gas gun. The system has been designed to allow for projectile velocity measurements to an accuracy of approx. 0.2 percent. The velocity system has been successfully tested in a velocity range of 3.5 km/s to 6.5 km/s.

  20. Investigating the link between gun possession and gun assault.

    PubMed

    Branas, Charles C; Richmond, Therese S; Culhane, Dennis P; Ten Have, Thomas R; Wiebe, Douglas J

    2009-11-01

    We investigated the possible relationship between being shot in an assault and possession of a gun at the time. We enrolled 677 case participants that had been shot in an assault and 684 population-based control participants within Philadelphia, PA, from 2003 to 2006. We adjusted odds ratios for confounding variables. After adjustment, individuals in possession of a gun were 4.46 (P < .05) times more likely to be shot in an assault than those not in possession. Among gun assaults where the victim had at least some chance to resist, this adjusted odds ratio increased to 5.45 (P < .05). On average, guns did not protect those who possessed them from being shot in an assault. Although successful defensive gun uses occur each year, the probability of success may be low for civilian gun users in urban areas. Such users should reconsider their possession of guns or, at least, understand that regular possession necessitates careful safety countermeasures.

  1. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    NASA Astrophysics Data System (ADS)

    Rimjaem, S.; Kusoljariyakul, K.; Thongbai, C.

    2014-02-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012©. RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance.

  2. The electric rail gun for space propulsion

    NASA Technical Reports Server (NTRS)

    Bauer, D. P.; Barber, J. P.; Vahlberg, C. J.

    1981-01-01

    An analytic feasibility investigation of an electric propulsion concept for space application is described. In this concept, quasistatic thrust due to inertial reaction to repetitively accelerated pellets by an electric rail gun is used to propel a spacecraft. The study encompasses the major subsystems required in an electric rail gun propulsion system. The mass, performance, and configuration of each subsystem are described. Based on an analytic model of the system mass and performance, the electric rail gun mission performance as a reusable orbital transfer vehicle (OTV) is analyzed and compared to a 30 cm ion thruster system (BIMOD) and a chemical propulsion system (IUS) for payloads with masses of 1150 kg and 2300 kg. For system power levels in the range from 25 kW(e) to 100 kW(e) an electric rail gun OTV is more attractive than a BIMOD system for low Earth orbit to geosynchronous orbit transfer durations in the range from 20 to 120 days.

  3. Pediatric eye injuries due to nonpowder guns in the United States, 2002-2012.

    PubMed

    Lee, Rachel; Fredrick, Douglas

    2015-04-01

    To identify epidemiologic trends in nonpowder gun-related pediatric eye injuries and to determine factors associated with severe injury requiring hospital admission. US emergency department data on pediatric eye injuries between 2002 and 2012 were reviewed using the National Electronic Injury Surveillance System. Literature review was conducted to determine trends in visual outcomes after treatment and use of eye protection. In 2012 roughly 3,161 children were treated in US emergency departments for nonpowder gun-related eye injuries. Since 2010 rates of severe nonpowder gun pediatric eye injury have increased by over 500% (P = 0.039). Specifically, while rates of hospital admission due to paintball gun eye injury have dropped precipitously (P = 0.0077), rates of admissions for air gun eye injuries have increased by over 600% since 2010 (P = 0.033). Children sustaining eye injury due to air guns are more likely to be diagnosed and admitted with foreign body or ocular puncture injury. Roughly 28% of documented cases of airsoft or BB gun-related injury had visual acuity worse than 20/50 after initial treatment. Over 98% of injuries occurred without eye protection. Air guns are rising in popularity and now account for the majority of pediatric eye injuries requiring hospital admissions. These eye injuries occur without ocular protection and may lead to permanent eye injury. Increasing regulations for eye protection, sales, and usage of air guns are needed to prevent serious pediatric eye injuries. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  4. A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Niraj; Pal, Udit Narayan; Prakash, Ram

    In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electronmore » beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.« less

  5. Long-Life/Low-Power Ion-Gun Cathode

    NASA Technical Reports Server (NTRS)

    Fitzgerald, D. J.

    1982-01-01

    New cathode has form of hollow tube through which gas enters region of high electron density, produced by electric discharge with auxiliary electrode referred to as "keeper." Ion-gun cathode emits electrons that bombard gas in chamber. Ions accelerated out of source are used to dope semiconductor material.

  6. Gun Safety

    MedlinePlus

    Many U.S. households have guns, but they can cause harm if not handled properly. Here are some things you can do to keep yourself and ... safe: Teach children that they shouldn't touch guns and that if they see a gun, to ...

  7. Compression of high-density 0.16 pC electron bunches through high field gradients for ultrafast single shot electron diffraction: The Compact RF Gun

    PubMed Central

    Daoud, Hazem; Floettmann, Klaus; Dwayne Miller, R. J.

    2017-01-01

    We present an RF gun design for single shot ultrafast electron diffraction experiments that can produce sub-100 fs high-charge electron bunches in the 130 keV energy range. Our simulations show that our proposed half-cell RF cavity is capable of producing 137 keV, 27 fs rms (60 fs FWHM), 106 electron bunches with an rms spot size of 276 μm and a transverse coherence length of 2.0 nm. The required operation power is 9.2 kW, significantly lower than conventional rf cavity designs and a key design feature. This electron source further relies on high electric field gradients at the cathode to simultaneously accelerate and compress the electron bunch to open up new space-time resolution domains for atomically resolved dynamics. PMID:28428973

  8. The progress of funnelling gun high voltage condition and beam test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Ben-Zvi, I.; Gassner, D. M.

    A prototype of a high average current polarized electron funneling gun as an eRHIC injector has been built at BNL. The gun was assembled and tested at Stangenes Incorporated. Two beams were generated from two GaAs photocathodes and combined by a switched combiner field. We observed the combined beams on a YAG crystal and measured the photocurrent by a Faraday cup. The gun has been shipped to Stony Brook University and is being tested there. In this paper we will describe the major components of the gun and recent beam test results. High voltage conditioning is discussed as well.

  9. Electron gun controlled smart structure

    DOEpatents

    Martin, Jeffrey W.; Main, John Alan; Redmond, James M.; Henson, Tammy D.; Watson, Robert D.

    2001-01-01

    Disclosed is a method and system for actively controlling the shape of a sheet of electroactive material; the system comprising: one or more electrodes attached to the frontside of the electroactive sheet; a charged particle generator, disposed so as to direct a beam of charged particles (e.g. electrons) onto the electrode; a conductive substrate attached to the backside of the sheet; and a power supply electrically connected to the conductive substrate; whereby the sheet changes its shape in response to an electric field created across the sheet by an accumulation of electric charge within the electrode(s), relative to a potential applied to the conductive substrate. Use of multiple electrodes distributed across on the frontside ensures a uniform distribution of the charge with a single point of e-beam incidence, thereby greatly simplifying the beam scanning algorithm and raster control electronics, and reducing the problems associated with "blooming". By placing a distribution of electrodes over the front surface of a piezoelectric film (or other electroactive material), this arrangement enables improved control over the distribution of surface electric charges (e.g. electrons) by creating uniform (and possibly different) charge distributions within each individual electrode. Removal or deposition of net electric charge can be affected by controlling the secondary electron yield through manipulation of the backside electric potential with the power supply. The system can be used for actively controlling the shape of space-based deployable optics, such as adaptive mirrors and inflatable antennae.

  10. Preliminary design of Viking Armored Gun System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gogolewski, R.P.; Cunningham, B.J.

    We have completed the preliminary design of our third lightweight armored fighting vehicle -- the Viking Armored Gun System (AGS). The AGS vehicle features a two-man crew, the Ares 75mm Universal Turret System, and the John Deere 4026R Rotary Engine. In the spirit of our earlier AFV designs, our primary concern is to provide the AGS with sufficient firepower and survivability while utilizing off-the-shelf'' sub-systems and components in order to reduce developmental time and acquisition cost. We still envision that prototypic vehicles could be built within a thirty (30) month developmental/demonstration program. We still believe that vehicles of this classmore » should be built and tested soon to assess their full tactical, operational, and strategic utilities.« less

  11. Numerical investigation of a laser gun injector at CEBAF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byung Yunn; Charles Sinclair; David Neuffer

    1993-08-23

    A laser gun injector is being developed based on the superconducting rf technologies established at CEBAF. This injector will serve as a high charge cw source for a high power free electron laser. It consists of a dc laser gun, a buncher, a cryounit and a chicane. Its space-charge-dominated performance has been thoroughly investigated using the time-consuming but more appropriate point-by-point space charge calculation method in PARMELA. The notion of ``conditioning for final bunching'' will be introduced. This concept has been built into the code and has greatly facilitated the optimization of the whole system to achieve the highest possiblemore » peak current while maintaining low emittance and low energy spread. Extensive parameter variation studies have shown that the design will perform better than the specifications.« less

  12. The Gun Dispute.

    ERIC Educational Resources Information Center

    Spitzer, Robert J.

    1999-01-01

    Explores the debate over gun ownership and gun control in the United States, focusing on the historic place of guns in U.S. society. The current national mood is more receptive than ever to restricting and regulating adolescent access to guns in light of recent school shootings. (SLD)

  13. Experimental investigation of a 1 kA/cm{sup 2} sheet beam plasma cathode electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Niraj, E-mail: niraj.ceeri@gmail.com; Narayan Pal, Udit; Prajesh, Rahul

    In this paper, a cold cathode based sheet-beam plasma cathode electron gun is reported with achieved sheet-beam current density ∼1 kA/cm{sup 2} from pseudospark based argon plasma for pulse length of ∼200 ns in a single shot experiment. For the qualitative assessment of the sheet-beam, an arrangement of three isolated metallic-sheets is proposed. The actual shape and size of the sheet-electron-beam are obtained through a non-conventional method by proposing a dielectric charging technique and scanning electron microscope based imaging. As distinct from the earlier developed sheet beam sources, the generated sheet-beam has been propagated more than 190 mm distance inmore » a drift space region maintaining sheet structure without assistance of any external magnetic field.« less

  14. Gun Safety (For Kids)

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Gun Safety KidsHealth / For Kids / Gun Safety What's in ... from guns outside the home. If You Have Guns in Your Home If your parents keep guns ...

  15. Observation of a variable sub-THz radiation driven by a low energy electron beam from a thermionic rf electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smirnov, A. V.; Agustsson, R.; Berg, W. J.

    We report observations of an intense sub-THz radiation extracted from a ~3 MeV electron beam with a flat transverse profile propagating between two parallel oversized copper gratings with side openings. Low-loss radiation outcoupling is accomplished using a horn antenna and a miniature permanent magnet separating sub-THz and electron beams. A tabletop experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet with a movable beam scraper producing sub-mm microbunches. The radiated energy of tens of micro-Joules per radio frequency macropulse is demonstrated. The frequency of the radiation peak was generated and tunedmore » across two frequency ranges: (476–584) GHz with 7% instantaneous spectrum bandwidth, and (311–334) GHz with 38% instantaneous bandwidth. In this study, the prototype setup features a robust compact source of variable frequency, narrow bandwidth sub-THz pulses.« less

  16. Observation of a variable sub-THz radiation driven by a low energy electron beam from a thermionic rf electron gun

    DOE PAGES

    Smirnov, A. V.; Agustsson, R.; Berg, W. J.; ...

    2015-09-29

    We report observations of an intense sub-THz radiation extracted from a ~3 MeV electron beam with a flat transverse profile propagating between two parallel oversized copper gratings with side openings. Low-loss radiation outcoupling is accomplished using a horn antenna and a miniature permanent magnet separating sub-THz and electron beams. A tabletop experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet with a movable beam scraper producing sub-mm microbunches. The radiated energy of tens of micro-Joules per radio frequency macropulse is demonstrated. The frequency of the radiation peak was generated and tunedmore » across two frequency ranges: (476–584) GHz with 7% instantaneous spectrum bandwidth, and (311–334) GHz with 38% instantaneous bandwidth. In this study, the prototype setup features a robust compact source of variable frequency, narrow bandwidth sub-THz pulses.« less

  17. Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    Southard, Adrian E.; Getty, Stephanie A.; Feng, Steven; Glavin, Daniel P.; Auciello, Orlando; Sumant, Anirudha

    2012-01-01

    Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and

  18. Interior of southeast gun chamber (labeled "Gun Turret No. Two), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior of southeast gun chamber (labeled "Gun Turret No. Two), showing gun mounting pad, wall rings, small niche, and opening to outside - U.S. Naval Base, Pearl Harbor, Battery Adair, Princeton Place, Pearl City, Honolulu County, HI

  19. Electrostatic focusing of directly heated linear filament gun using EGUN

    NASA Astrophysics Data System (ADS)

    Iqbal, Munawar; Lodhi, M. A. K.; Majeed, Zahid; Batani, Dimitri

    2011-06-01

    This paper presents the optimization of a line source rectangular electron gun using electrostatic focusing. We optimized the gun by shaping the configuration of its electrodes in order to achieve the desired focusing characteristics, namely maximum focusing distance and minimum beam spread. The optimization has been carried out using the software EGUN. We have also simplified the gun design using only one focusing electrode at the same potential as that of the cathode and by avoiding magnetic focusing field, separate focusing electrodes and additional power supply, thus minimizing the cost without any loss in its accuracy and efficient performance. This gun with the optimum configuration was used in actual experiment and the results of the simulation were compared with the experimental measurements.

  20. A description of the new 3D electron gun and collector modeling tool: MICHELLE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petillo, J.; Mondelli, A.; Krueger, W.

    1999-07-01

    A new 3D finite element gun and collector modeling code is under development at SAIC in collaboration with industrial partners and national laboratories. This development program has been designed specifically to address the shortcomings of current simulation and modeling tools. In particular, although there are 3D gun codes that exist today, their ability to address fine scale features is somewhat limited in 3D due to disparate length scales of certain classes of devices. Additionally, features like advanced emission rules, including thermionic Child's law and comprehensive secondary emission models also need attention. The program specifically targets problems classes including gridded-guns, sheet-beammore » guns, multi-beam devices, and anisotropic collectors. The presentation will provide an overview of the program objectives, the approach to be taken by the development team, and a status of the project.« less

  1. Robe Development for Electrical Conductivity Analysis in an Electron Gun Produced Helium Plasma

    NASA Technical Reports Server (NTRS)

    Bragg-Sitton, Shannon M.; Bitteker, Leo; Rodgers, Stephen L. (Technical Monitor)

    2002-01-01

    The use of magnetohydrodynamic (MHD) power conversion systems, potentially coupled with a fission power source, is currently being investigated as a driver for an advanced propulsion system, such as a plasma thruster. The efficiency of a MHD generator is strongly dependent on the electrical conductivity of the fluid that passes through the generator; power density increases as fluid conductivity increases. Although traditional MHD flows depend on thermal ionization to enhance the electrical conductivity, ionization due to nuclear interactions may achieve a comparable or improved conductivity enhancement while avoiding many of the limitations inherent to thermal ionization. Calculations suggest that nuclear-enhanced electrical conductivity increases as the neutron flux increases; conductivity of pure He-3 greater than 10 mho/m may be achievable if exposed to a flux greater than 10(exp 12) neutrons/cm2/s.) However, this remains to be demonstrated experimentally. An experimental facility has been constructed at the Propulsion Research Center at the NASA Marshall Space Flight Center, using helium as the test fluid. High energy electrons will be used to simulate the effects of neutron-induced ionization of helium gas to produce a plasma. These experiments will be focused on diagnosis of the plasma in a virtually static system; results will be applied to future tests with a MHD system. Initial experiments will utilize a 50 keV electron gun that can operate at up to a current of 200 micro A. Spreading the electron beam over a four inch diameter window results in an electron flux of 1.5x 10(exp 13) e/sq cm/s. The equivalent neutron flux that would produce the same ionization fraction in helium is 1x10(exp 12) n/sq cm/s. Experiments will simulate the neutron generated plasma modeled by Bitteker, which takes into account the products of thermal neutron absorption in He-3, and includes various ion species in estimating the conductivity of the resulting plasma. Several

  2. Engineering design of the PLX- α coaxial gun

    NASA Astrophysics Data System (ADS)

    Cruz, Edward; Brockington, Samuel; Case, Andrew; Luna, Marco; Witherspoon, Douglas; Langendorf, Samuel

    2016-10-01

    We describe the engineering and technical aspects of the coaxial gun designed for the 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion. Each coaxial gun incorporates a fast, dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. Alpha1 and Alpha2 guns are compared, with emphasis on the improvements on Alpha2, which include a faster more robust gas valve, an improved electrode contour, a custom 600- μF, 5-kV pfn, and a set of six inline sparkgap switches operated in parallel. The switch and pfn configurations are mounted directly to the back of the gun, and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. We will provide a detailed overview of the design choices made for the PLX- α coaxial gun. This work supported by the ARPA-E ALPHA Program.

  3. Characterization of a Carbon Nanotube Field Emission Electron Gun for the VAPoR Miniaturized Pyrolysis-Time-of-Flight Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    Getty, Stephanie; Li, Mary; Costen, Nicholas; Hess, Larry; Feng, Steve; King, Todd; Brinckerhoff, William; Mahaffy, Paul; Glavin, Daniel

    2009-01-01

    We are developing the VAPoR (Volatile Analysis by Pyrolysis of Regolith) instrument towards studying soil composition, volatiles, and trapped noble gases in the polar regions of the Moon. VAPOR will ingest a soil sample and conduct analysis by pyrolysis and time-of-flight mass spectrometry (ToF-MS). Here, we describe miniaturization efforts within this development, including a carbon nanotube (CNT) field emission electron gun that is under consideration for use as the electron impact ionization source for the ToF-MS.

  4. A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators.

    PubMed

    Constantin, Dragoş E; Fahrig, Rebecca; Keall, Paul J

    2011-07-01

    Using magnetic resonance imaging (MRI) for real-time guidance during radiotherapy is an active area of research and development. One aspect of the problem is the influence of the MRI scanner, modeled here as an external magnetic field, on the medical linear accelerator (linac) components. The present work characterizes the behavior of two medical linac electron guns with external magnetic fields for in-line and perpendicular orientations of the linac with respect to the MRI scanner. Two electron guns, Litton L-2087 and Varian VTC6364, are considered as representative models for this study. Emphasis was placed on the in-line design approach in which case the MRI scanner and the linac axes of symmetry coincide and assumes no magnetic shielding of the linac. For the in-line case, the magnetic field from a 0.5 T open MRI (GE Signa SP) magnet with a 60 cm gap between its poles was computed and used in full three dimensional (3D) space charge simulations, whereas for the perpendicular case the magnetic field was constant. For the in-line configuration, it is shown that the electron beam is not deflected from the axis of symmetry of the gun and the primary beam current does not vanish even at very high values of the magnetic field, e.g., 0.16 T. As the field strength increases, the primary beam current has an initial plateau of constant value after which its value decreases to a minimum corresponding to a field strength of approximately 0.06 T. After the minimum is reached, the current starts to increase slowly. For the case when the beam current computation is performed at the beam waist position the initial plateau ends at 0.016 T for Litton L-2087 and at 0.012 T for Varian VTC6364. The minimum value of the primary beam current is 27.5% of the initial value for Litton L-2087 and 22.9% of the initial value for Varian VTC6364. The minimum current is reached at 0.06 and 0.062 T for Litton L-2087 and Varian VTC6364, respectively. At 0.16 T the beam current increases to 40

  5. A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constantin, Dragos E.; Fahrig, Rebecca; Keall, Paul J.

    Purpose: Using magnetic resonance imaging (MRI) for real-time guidance during radiotherapy is an active area of research and development. One aspect of the problem is the influence of the MRI scanner, modeled here as an external magnetic field, on the medical linear accelerator (linac) components. The present work characterizes the behavior of two medical linac electron guns with external magnetic fields for in-line and perpendicular orientations of the linac with respect to the MRI scanner. Methods: Two electron guns, Litton L-2087 and Varian VTC6364, are considered as representative models for this study. Emphasis was placed on the in-line design approachmore » in which case the MRI scanner and the linac axes of symmetry coincide and assumes no magnetic shielding of the linac. For the in-line case, the magnetic field from a 0.5 T open MRI (GE Signa SP) magnet with a 60 cm gap between its poles was computed and used in full three dimensional (3D) space charge simulations, whereas for the perpendicular case the magnetic field was constant. Results: For the in-line configuration, it is shown that the electron beam is not deflected from the axis of symmetry of the gun and the primary beam current does not vanish even at very high values of the magnetic field, e.g., 0.16 T. As the field strength increases, the primary beam current has an initial plateau of constant value after which its value decreases to a minimum corresponding to a field strength of approximately 0.06 T. After the minimum is reached, the current starts to increase slowly. For the case when the beam current computation is performed at the beam waist position the initial plateau ends at 0.016 T for Litton L-2087 and at 0.012 T for Varian VTC6364. The minimum value of the primary beam current is 27.5% of the initial value for Litton L-2087 and 22.9% of the initial value for Varian VTC6364. The minimum current is reached at 0.06 and 0.062 T for Litton L-2087 and Varian VTC6364, respectively. At 0.16 T

  6. A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators

    PubMed Central

    Constantin, Dragoş E.; Fahrig, Rebecca; Keall, Paul J.

    2011-01-01

    Purpose: Using magnetic resonance imaging (MRI) for real-time guidance during radiotherapy is an active area of research and development. One aspect of the problem is the influence of the MRI scanner, modeled here as an external magnetic field, on the medical linear accelerator (linac) components. The present work characterizes the behavior of two medical linac electron guns with external magnetic fields for in-line and perpendicular orientations of the linac with respect to the MRI scanner. Methods: Two electron guns, Litton L-2087 and Varian VTC6364, are considered as representative models for this study. Emphasis was placed on the in-line design approach in which case the MRI scanner and the linac axes of symmetry coincide and assumes no magnetic shielding of the linac. For the in-line case, the magnetic field from a 0.5 T open MRI (GE Signa SP) magnet with a 60 cm gap between its poles was computed and used in full three dimensional (3D) space charge simulations, whereas for the perpendicular case the magnetic field was constant. Results: For the in-line configuration, it is shown that the electron beam is not deflected from the axis of symmetry of the gun and the primary beam current does not vanish even at very high values of the magnetic field, e.g., 0.16 T. As the field strength increases, the primary beam current has an initial plateau of constant value after which its value decreases to a minimum corresponding to a field strength of approximately 0.06 T. After the minimum is reached, the current starts to increase slowly. For the case when the beam current computation is performed at the beam waist position the initial plateau ends at 0.016 T for Litton L-2087 and at 0.012 T for Varian VTC6364. The minimum value of the primary beam current is 27.5% of the initial value for Litton L-2087 and 22.9% of the initial value for Varian VTC6364. The minimum current is reached at 0.06 and 0.062 T for Litton L-2087 and Varian VTC6364, respectively. At 0.16 T the

  7. Temporal association between federal gun laws and the diversion of guns to criminals in Milwaukee.

    PubMed

    Webster, Daniel W; Vernick, Jon S; Bulzacchelli, Maria T; Vittes, Katherine A

    2012-02-01

    The practices of licensed gun dealers can threaten the safety of urban residents by facilitating the diversion of guns to criminals. In 2003, changes to federal law shielded gun dealers from the release of gun trace data and provided other protections to gun dealers. The 14-month period during which the dealer did not sell junk guns was associated with a 68% reduction in the diversion of guns to criminals within a year of sale by the dealer and a 43% increase in guns diverted to criminals following sales by other dealers. The laws were associated with a 203% increase in the number of guns diverted to criminals within a year of sale by the gun store, which was the focus of this study. Policies which affect gun dealer accountability appeared to influence the diversion of guns to criminals.

  8. Identification and modeling of the electrohydraulic systems of the main gun of a main battle tank

    NASA Astrophysics Data System (ADS)

    Campos, Luiz C. A.; Menegaldo, Luciano L.

    2012-11-01

    The black-box mathematical models of the electrohydraulic systems responsible for driving the two degrees of freedom (elevation and azimuth) of the main gun of a main battle tank (MBT) were identified. Such systems respond to gunner's inputs while acquiring and tracking targets. Identification experiments were designed to collect simultaneous data from two inertial measurement units (IMU) installed at the gunner's handle (input) and at the center of rotation of the turret (output), for the identification of the azimuth system. For the elevation system, IMUs were installed at the gunner's handle (input) and at the breech of the gun (output). Linear accelerations and angular rates were collected for both input and output. Several black-box model architectures were investigated. As a result, nonlinear autoregressive with exogenous variables (NARX) second order model and nonlinear finite impulse response (NFIR) fourth order model, demonstrate to best fit the experimental data, with low computational costs. The derived models are being employed in a broader research, aiming to reproduce such systems in a laboratory virtual main gun simulator.

  9. Subcaliber Guns

    DTIC Science & Technology

    1988-06-16

    310-6 11. TITLE (Include Security Classification) "SUBCALIBER GUNS " 12. PERSONAL AUTHOR(S) 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT...necessary and identify by block number) FIELD GROUP SUB-GROUP 4Large caliber weapons, .,Subcaliber guns (" J-) Parent weapons.; Small caliber weapons’y...19, ABSTRACT (Continue on reverse if necessary and identify by block number) Provides procedures for determining the suitability of subcaliber guns

  10. Effects of Exposure to Gun Violence in Movies on Children's Interest in Real Guns.

    PubMed

    Dillon, Kelly P; Bushman, Brad J

    2017-11-01

    More US children die by accidental gun use than children in other developed countries. One factor that can influence children's interest in guns is exposure to media containing guns. To test whether children who see a movie containing guns will handle a real gun longer and will pull the trigger more times than children who see the same movie not containing guns. One hundred four children aged 8 to 12 years recruited through advertisements were randomly assigned in pairs to watch a 20-minute PG-rated movie containing or not containing guns in a university laboratory. Children then played with toys and games in a room for 20 minutes while being video recorded. A cabinet in the room contained a real (disabled) gun with a sensor counting trigger pulls. Recordings were coded for the time spent holding the gun and in aggressive play. Data were collected from July 15, 2015, through January 1, 2016, and analyzed using generalized estimating equations (Tweedie log-link for time spent holding the gun; Poisson log-link for pulling the trigger). The 2 main outcomes were time spent holding the gun and the number of trigger pulls. Control variables included sex, age, trait aggressiveness, exposure to violent media, interest in guns, and number of guns at home. Among the 104 study participants (62 boys [59.6%] and 42 girls [40.4%]; mean (SD) age, 9.9 [1.5] years), the adjusted median number of trigger pulls among children who saw the movie containing guns was 2.8 (interquartile range [IQR], 0.2-2.8) compared with 0.01 (IQR, 0.01-0.2) among children who saw the movie not containing guns (adjusted odds ratio, 22.3; 95% CI, 6.0-83.4; P < .001). The adjusted median number of seconds spent holding the gun among children who saw a movie containing guns was 53.1 (IQR, 35.5-53.1) compared with 11.1 (IQR, 10.7-16.7) among children who saw the movie not containing guns (adjusted odds ratio, 3.0; 95% CI, 0.9-9.9; P = .07). Qualitative analyses on 4 pairs from each condition found

  11. Gun Theft and Crime.

    PubMed

    Cook, Philip J

    2018-06-01

    Some law enforcement officials and other observers have asserted that theft is the primary source of guns to crime. In fact, the role of theft in supplying the guns used in robbery, assault, and murder is unknown, and current evidence provides little guidance about whether an effective program to reduce gun theft would reduce gun violence. The current article analyzes publicly available national data on gun theft together with a unique data set for Chicago. The results tend to support a conclusion that stolen guns play only a minor role in crime. First, publicly available data are used to calculate that thefts are only about 1% of all gun transactions nationwide. Second, an analysis of original data from Chicago demonstrates that less than 3% of crime guns recovered by the police have been reported stolen to the Chicago Police Department (CPD). If a gun is reported stolen, there is a 20% chance that it will be recovered, usually in conjunction with an arrest for illegal carrying. Less than half of those picked up with a stolen gun have a criminal record that includes violent offenses. Third, results from surveys of convicted criminals, both nationally and in Chicago, suggest that it is rare for respondents to have stolen the gun used in their most recent crime. The data on which these results are based have various shortcomings. A research agenda is proposed that would provide more certainty about the role of theft.

  12. Electron Gun and Collector Design for 94 GHz Gyro-amplifiers.

    NASA Astrophysics Data System (ADS)

    Nguyen, K.; Danly, B.; Levush, B.; Blank, M.; True, D.; Felch, K.; Borchard, P.

    1997-05-01

    The electrical design of the magnetron injection gun and collector for high average power TE_01 gyro-amplifiers has recently been completed using the EGUN(W.B. Herrmannsfeldt, AIP Conf. Proc. 177, pp. 45-58, 1988.) and DEMEOS(R. True, AIP Conf. Proc. 297, pp. 493-499, 1993.) codes. The gun employs an optimized double-anode geometry and a radical cathode cone angle of 500 to achieve superior beam optics that are relatively insensitive to electrode misalignments and field errors. Perpendicular velocity spread of 1.6% at an perpendicular to axial velocity ratio of 1.52 is obtained for a 6 A, 65 kV beam. The 1.28" diameter collector, which also serves as the output waveguide, has an average power density of < 350 W/cm^2 for a 59 kW average power beam. Details will be presented at the conference.

  13. Guns and Violence. Current Controversies.

    ERIC Educational Resources Information Center

    Kim, Henny H., Ed.

    This book focuses on gun violence and gun control, presenting both sides of arguments about firearms ownership and gun control. Each of five chapters poses a question about gun control and provides answers for both sides of the question. The following essays are included: (1) "Gun Violence Is Becoming an Epidemic" (Bob Herbert); (2) "Gun Violence…

  14. The 20 kilovolt rocket borne electron accelerator. [equipment specifications

    NASA Technical Reports Server (NTRS)

    Harrison, R.

    1973-01-01

    The accelerator system is a preprogrammed multi-voltage system capable of operating at a current level of 1/2 ampere at the 20 kilovolt level. The five major functional areas which comprise this system are: (1) Silver zinc battery packs; (2) the electron gun assembly; (3) gun control and opening circuits; (4) the telemetry conditioning section; and (5) the power conversion section.

  15. Bunch compression efficiency of the femtosecond electron source at Chiang Mai University

    NASA Astrophysics Data System (ADS)

    Thongbai, C.; Kusoljariyakul, K.; Saisut, J.

    2011-07-01

    A femtosecond electron source has been developed at the Plasma and Beam Physics Research Facility (PBP), Chiang Mai University (CMU), Thailand. Ultra-short electron bunches can be produced with a bunch compression system consisting of a thermionic cathode RF-gun, an alpha-magnet as a magnetic bunch compressor, and a linear accelerator as a post acceleration section. To obtain effective bunch compression, it is crucial to provide a proper longitudinal phase-space distribution at the gun exit matched to the subsequent beam transport system. Via beam dynamics calculations and experiments, we investigate the bunch compression efficiency for various RF-gun fields. The particle distribution at the RF-gun exit will be tracked numerically through the alpha-magnet and beam transport. Details of the study and results leading to an optimum condition for our system will be presented.

  16. Reduction of Gun Erosion and Correlation of Gun Erosion Measurements

    NASA Technical Reports Server (NTRS)

    Bogdanoff, Dave; Wercinski, Paul (Technical Monitor)

    1997-01-01

    Gun barrel erosion is serious problem with two-stage light gas guns. Excessive barrel erosion can lead to poor or failed launches and frequent barrel changes, with the corresponding down time. Also, excessive barrel erosion can limit the maximum velocity obtainable by loading down the hydrogen working gas with eroded barrel material. Guided by a CFD code, the operating conditions of the Ames 0.5-inch gun were modified to reduce barrel erosion. The changes implemented included: (1) reduction in the piston mass, powder mass and hydrogen fill pressure; and (2) reduction in pump tube volume, while maintaining hydrogen mass. The latter change was found, in particular, to greatly reduce barrel erosion. For muzzle velocity ranges of 6.1 - 6.9 km/sec, the barrel erosion was reduced by a factor of 10. Even for the higher muzzle velocity range of 7.0 - 8.2 km/sec, the barrel erosion was reduced by a factor of 4. Gun erosion data from the Ames 0.5-inch, 1.0-inch, and 1.5-inch guns operated over a wide variety of launch conditions was examined and it was found that this data could be correlated using four different parameters: normalized powder charge energy, normalized hydrogen energy density, normalized pump tube volume and barrel diameter. The development of the correlation and the steps used to collapse the experimental data are presented. Over a certain parameter range in the correlation developed, the barrel erosion per shot is found to increase very rapidly. The correlation should prove useful in the selection of gun operating conditions and the design of new guns. Representative shapes of eroded gun barrels are also presented.

  17. Multiobjective optimization design of an rf gun based electron diffraction beam line

    NASA Astrophysics Data System (ADS)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan; Maxson, Jared

    2017-03-01

    Multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line comprised of a 100 MV /m 1.6-cell normal conducting rf (NCRF) gun, as well as a nine-cell 2 π /3 bunching cavity placed between two solenoids, have been performed. These include optimization of the normalized transverse emittance as a function of bunch charge, as well as optimization of the transverse coherence length as a function of the rms bunch length of the beam at the sample location for a fixed charge of 1 06 electrons. Analysis of the resulting solutions is discussed in terms of the relevant scaling laws, and a detailed description of one of the resulting solutions from the coherence length optimizations is given. For a charge of 1 06 electrons and final beam sizes of σx≥25 μ m and σt≈5 fs , we found a relative coherence length of Lc ,x/σx≈0.07 using direct optimization of the coherence length. Additionally, based on optimizations of the emittance as a function of final bunch length, we estimate the relative coherence length for bunch lengths of 30 and 100 fs to be roughly 0.1 and 0.2 nm /μ m , respectively. Finally, using the scaling of the optimal emittance with bunch charge, for a charge of 1 05 electrons, we estimate relative coherence lengths of 0.3, 0.5, and 0.92 nm /μ m for final bunch lengths of 5, 30 and 100 fs, respectively.

  18. Gun Sales. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Minimal federal regulations on firearm sales have facilitated the proliferation of guns, gun owners, and gun dealers in the United States. This fact sheet offers data on the growing number of firearm dealers, the relative ease of obtaining and keeping a license to sell guns from the Federal Bureau of Alcohol, Tobacco, and Firearms, the lack of…

  19. Numerical modeling of materials processing applications of a pulsed cold cathode electron gun

    NASA Astrophysics Data System (ADS)

    Etcheverry, J. I.; Martínez, O. E.; Mingolo, N.

    1998-04-01

    A numerical study of the application of a pulsed cold cathode electron gun to materials processing is performed. A simple semiempirical model of the discharge is used, together with backscattering and energy deposition profiles obtained by a Monte Carlo technique, in order to evaluate the energy source term inside the material. The numerical computation of the heat equation with the calculated source term is performed in order to obtain useful information on melting and vaporization thresholds, melted radius and depth, and on the dependence of these variables on processing parameters such as operating pressure, initial voltage of the discharge and cathode-sample distance. Numerical results for stainless steel are presented, which demonstrate the need for several modifications of the experimental design in order to achieve a better efficiency.

  20. Engineering design of the PLX- α coaxial gun

    NASA Astrophysics Data System (ADS)

    Cruz, E.; Brockington, S.; Case, A.; Luna, M.; Witherspoon, F. D.; Thio, Y. C. Francis; PLX-α Team

    2017-10-01

    We describe the engineering and technical improvements, as well as provide a detailed overview of the design choices, of the latest PLX- α coaxial gun designed for the 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion. Each coaxial gun incorporates a fast, dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The evolution of the latest Alpha gun is presented with emphasis on its upgraded performance. Changes include a faster more robust gas valve, better-quality ceramic insulator material and enhancements to overall design layout. These changes result in a gun with increased repeatability, reduced potential failure modes, improved fault tolerance and better than expected efficiency. A custom 600- μF, 5-kV pfn and a set of six inline sparkgap switches operated in parallel are mounted directly to the back of the gun, and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  1. Temperature Controller System for Gas Gun Targets

    NASA Astrophysics Data System (ADS)

    Bucholtz, Scott; Sheffield, Stephen

    2005-07-01

    A temperature controller system capable of heating and cooling gas gun targets over the range -75 C to +200 C was designed and tested. The system uses cold nitrogen gas from a liquid nitrogen Dewar for cooling and compressed air for heating. Two gas flow heaters control the gas temperature for both heating and cooling. One heater controls the temperature of the target mounting plate and the other the temperature of a copper tubing coil surrounding the target. Each heater is separately adjustable, so the target material will achieve a uniform temperature throughout its volume. A magnetic gauge with integrated thermocouples was developed to measure the internal temperature of the target. Using this system shock experiments, including equation-of-state measurements and shock initiation of high explosives, can be performed over a range of initial temperatures. Successful tests were completed on Teflon samples. This work was supported by the NNSA Enhanced Surveillance Campaign through contract DE-ACO4-01AL66850.

  2. Temperature Controller System for Gas Gun Targets

    NASA Astrophysics Data System (ADS)

    Bucholtz, S. M.; Gehr, R. J.; Rupp, T. D.; Sheffield, S. A.; Robbins, D. L.

    2006-07-01

    A temperature controller system capable of heating and cooling gas gun targets over the range -75°C to +120°C was designed and tested. The system uses cold nitrogen gas from a liquid nitrogen Dewar for cooling and compressed air for heating. Two gas flow heaters control the gas temperature for both heating and cooling. One heater controls the temperature of the target mounting plate and the other the temperature of a copper tubing coil surrounding the target. Each heater is separately adjustable, so the target material will achieve a uniform temperature throughout its volume. A magnetic gauge membrane with integrated thermocouples was developed to measure the internal temperature of the target. Using this system, multiple magnetic gauge shock experiments, including equation-of-state measurements and shock initiation of high explosives, can be performed over a range of initial temperatures. Successful heating and cooling tests were completed on Teflon samples.

  3. Racism, gun ownership and gun control: biased attitudes in US whites may influence policy decisions.

    PubMed

    O'Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites' paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions.

  4. Design of a Rail Gun System for Mitigating Disruptions in Fusion Reactors

    NASA Astrophysics Data System (ADS)

    Lay, Wei-Siang

    Magnetic fusion devices, such as the tokamak, that carry a large amount of current to generate the plasma confining magnetic fields have the potential to lose magnetic stability control. This can lead to a major plasma disruption, which can cause most of the stored plasma energy to be lost to localized regions on the walls, causing severe damage. This is the most important issue for the $20B ITER device (International Thermonuclear Experimental Reactor) that is under construction in France. By injecting radiative materials deep into the plasma, the plasma energy could be dispersed more evenly on the vessel surface thus mitigating the harmful consequences of a disruption. Methods currently planned for ITER rely on the slow expansion of gases to propel the radiative payloads, and they also need to be located far away from the reactor vessel, which further slows down the response time of the system. Rail guns are being developed for aerospace applications, such as for mass transfer from the surface of the moon and asteroids to low earth orbit. A miniatured version of this aerospace technology seems to be particularly well suited to meet the fast time response needs of an ITER disruption mitigation system. Mounting this device close to the reactor vessel is also possible, which substantially increases its performance because the stray magnetic fields near the vessel walls could be used to augment the rail gun generated magnetic fields. In this thesis, the potential viability on Rail Gun based DMS is studied to investigate its projected fast time response capability by design, fabrication, and experiment of an NSTX-U sized rail gun system. Material and geometry based tests are used to find the most suitable armature design for this system for which the desirable attributes are high specific stiffness and high electrical conductivity. With the best material in these studies being aluminum 7075, the experimental Electromagnetic Particle Injector (EPI) system has propelled

  5. Bolt-on source of spin-polarized electrons for inverse photoemission

    NASA Astrophysics Data System (ADS)

    Schedin, Fredrik; Warburton, Ranald; Thornton, Geoff

    1998-06-01

    We have developed a portable spin-polarized electron gun which can be bolted on to an ultrahigh vacuum chamber. The gun has been successfully operated with an electron gun to target distance of about 150 mm. This allows accommodation of other surface science equipment in the same vacuum system. The spin-polarized electrons are obtained via photoemission from a negative electron affinity GaAs(001) surface with circularly polarized light. A transversely polarized beam is achieved with a 90° electrostatic deflector. A set of two three-element electrostatic tube lenses are employed to transport and to focus the electrons onto a target. The measured transmission through the electron optics is >70% for electron energies in the range 7-20 eV. This is achieved by using large diameter electron transport lenses. The energy resolution of the electron beam is measured to be better than 0.27 eV and the polarization is determined to be 25±5%.

  6. A THz Spectroscopy System Based on Coherent Radiation from Ultrashort Electron Bunches

    NASA Astrophysics Data System (ADS)

    Saisut, J.; Rimjaem, S.; Thongbai, C.

    2018-05-01

    A spectroscopy system will be discussed for coherent THz transition radiation emitted from short electron bunches, which are generated from a system consisting of an RF gun with a thermionic cathode, an alpha-magnet as a magnetic bunch compressor, and a linear accelerator for post-acceleration. The THz radiation is generated as backward transition radiation when electron bunches pass through an aluminum foil. The emitted THz transition radiation, which is coherent at wavelengths equal to and longer than the electron bunch length, is coupled to a Michelson interferometer. The performance of the spectroscopy system employing a Michelson interferometer is discussed. The radiation power spectra under different conditions are presented. As an example, the optical constant of a silicon wafer can be obtained using the dispersive Fourier transform spectroscopy (DFTS) technique.

  7. A Biomechanical Assessment of Hand/Arm Force with Pneumatic Nail Gun Actuation Systems.

    PubMed

    Lowe, Brian D; Albers, James; Hudock, Stephen D

    2014-09-01

    A biomechanical model is presented, and combined with measurements of tip press force, to estimate total user hand force associated with two pneumatic nail gun trigger systems. The contact actuation trigger (CAT) can fire a nail when the user holds the trigger depressed first and then "bumps" the nail gun tip against the workpiece. With a full sequential actuation trigger (SAT) the user must press the tip against the workpiece prior to activating the trigger. The SAT is demonstrably safer in reducing traumatic injury risk, but increases the duration (and magnitude) of tip force exertion. Time integrated (cumulative) hand force was calculated for a single user from measurements of the tip contact force with the workpiece and transfer time between nails as inputs to a static model of the nail gun and workpiece in two nailing task orientations. The model shows the hand force dependence upon the orientation of the workpiece in addition to the trigger system. Based on standard time allowances from work measurement systems (i.e. Methods-Time Measurement - 1) it is proposed that efficient application of hand force with the SAT in maintaining tip contact can reduce force exertion attributable to the sequential actuation trigger to 2-8% (horizontal nailing) and 9-20% (vertical nailing) of the total hand/arm force. The present model is useful for considering differences in cumulative hand/arm force exposure between the SAT and CAT systems and may explain the appeal of the CAT trigger in reducing the user's perception of muscular effort.

  8. A Biomechanical Assessment of Hand/Arm Force with Pneumatic Nail Gun Actuation Systems

    PubMed Central

    Lowe, Brian D.; Albers, James; Hudock, Stephen D.

    2015-01-01

    A biomechanical model is presented, and combined with measurements of tip press force, to estimate total user hand force associated with two pneumatic nail gun trigger systems. The contact actuation trigger (CAT) can fire a nail when the user holds the trigger depressed first and then “bumps” the nail gun tip against the workpiece. With a full sequential actuation trigger (SAT) the user must press the tip against the workpiece prior to activating the trigger. The SAT is demonstrably safer in reducing traumatic injury risk, but increases the duration (and magnitude) of tip force exertion. Time integrated (cumulative) hand force was calculated for a single user from measurements of the tip contact force with the workpiece and transfer time between nails as inputs to a static model of the nail gun and workpiece in two nailing task orientations. The model shows the hand force dependence upon the orientation of the workpiece in addition to the trigger system. Based on standard time allowances from work measurement systems (i.e. Methods-Time Measurement - 1) it is proposed that efficient application of hand force with the SAT in maintaining tip contact can reduce force exertion attributable to the sequential actuation trigger to 2–8% (horizontal nailing) and 9–20% (vertical nailing) of the total hand/arm force. The present model is useful for considering differences in cumulative hand/arm force exposure between the SAT and CAT systems and may explain the appeal of the CAT trigger in reducing the user’s perception of muscular effort. PMID:26321780

  9. Women and Guns. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Many gun manufacturers market guns to women claiming a gun can provide protection. Statistics provided in this fact sheet indicate gun ownership may provide a false sense of security that can be fatal, since the greatest threat to a woman comes from the people and guns within her own home. Contrary to "typical" scenarios created by advertisers,…

  10. Development of spray guns for the application of rigid foam insulation

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1993-01-01

    The paper describes the activities initiated to improve the existing spray gun system used for spraying insulating foam on the External Tank of the Space Shuttle, due to the quality variations of the applied foam noted in the past. Consideration is given to the two tasks of the project: (1) investigations of possible improvements, as an interim measure, to the spray gun currently used to apply the large acreage spray-on-foam insulation and the evaluation of other commercial equipment; and (2) the design and fabrication of a new automatic spray gun. The design and operation of the currently used Binks 43 PA spray gun are described together with several new breadboard spray guns designed and fabricated and the testing procedures developed. These new guns include the Modular Automatic Foam spray gun, the Ball Valve spray gun, and the Tapered Plug Valve (TPV) gun. As a result of tests, the TPV spray gun is recommended to replace the currently used automatic spray gun.

  11. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    NASA Astrophysics Data System (ADS)

    Chen, Teng; Elias, Luis R.

    1995-02-01

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations.

  12. High resolution ceramic gun for projection CRT

    NASA Astrophysics Data System (ADS)

    Muchi, T.; Tagami, S.; Saito, T.

    1995-08-01

    A ceramic resistor with high-resistivity and a low thermal coefficient has been developed. The use of this ceramic material as a cylindrical electrode realizes an electrostatic lens with low spherical aberration. A ceramic electron gun based on a new concept has been developed for high resolution projection CRTs.

  13. Gun Possession among American Youth: A Discovery-Based Approach to Understand Gun Violence

    PubMed Central

    Ruggles, Kelly V.; Rajan, Sonali

    2014-01-01

    Objective To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions’ Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Results Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001–2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association “fingerprint” to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Conclusions Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described. PMID:25372864

  14. Gun possession among American youth: a discovery-based approach to understand gun violence.

    PubMed

    Ruggles, Kelly V; Rajan, Sonali

    2014-01-01

    To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions' Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001-2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association "fingerprint" to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described.

  15. Racism, Gun Ownership and Gun Control: Biased Attitudes in US Whites May Influence Policy Decisions

    PubMed Central

    O’Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Objective Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. Method The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. Results After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Conclusions Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites’ paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions. PMID:24204867

  16. Effects of a Gun Dealer's Change in Sales Practices on the Supply of Guns to Criminals

    PubMed Central

    Vernick, Jon S.; Bulzacchelli, Maria T.

    2006-01-01

    Licensed gun dealers are a major conduit for gun trafficking. Prior to May 1999, a single gun store sold more than half of the guns recovered from criminals in Milwaukee, WI, shortly following retail sale. On May 10, 1999, the store stopped selling small, inexpensive handguns popular with criminals, often called “Saturday night specials.” The purpose of this study was to estimate the effect of this gun store's changed sales practices on criminals' acquisition of new guns. We used an interrupted time-series design with comparisons to test for changes in the number of guns that police recovered from criminals within a year of retail sale following the gun dealer's new sales policy. The dealer's changed sales policy was associated with a 96% decrease in recently sold, small, inexpensive handguns use in crime in Milwaukee, a 73% decrease in crime guns recently sold by this dealer, and a 44% decrease in the flow of all new, trafficked guns to criminals in Milwaukee. The findings demonstrate the substantial impact that a single gun store's sales practices can have on the supply of new guns to criminals. Proposed anti-gun-trafficking efforts in other cities could benefit from targeting problem retail outlets. PMID:16937085

  17. First test of BNL electron beam ion source with high current density electron beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, Alexander, E-mail: pikin@bnl.gov; Alessi, James G., E-mail: pikin@bnl.gov; Beebe, Edward N., E-mail: pikin@bnl.gov

    A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm{sup 2} and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, themore » EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given.« less

  18. THz and Sub-THz Capabilities of a Table-Top Radiation Source Driven by an RF Thermionic Electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smirnov, Alexei V.; Agustsson, R.; Boucher, S.

    Design features and experimental results are presented for a sub-mm wave source [1] based on APS RF thermionic electron gun. The setup includes compact alpha-magnet, quadrupoles, sub-mm-wave radiators, and THz optics. The sub-THz radiator is a planar, oversized structure with gratings. Source upgrade for generation frequencies above 1 THz is discussed. The THz radiator will use a short-period undulator having 1 T field amplitude, ~20 cm length, and integrated with a low-loss oversized waveguide. Both radiators are integrated with a miniature horn antenna and a small ~90°-degree in-vacuum bending magnet. The electron beamline is designed to operate different modes includingmore » conversion to a flat beam interacting efficiently with the radiator. The source can be used for cancer diagnostics, surface defectoscopy, and non-destructive testing. Sub-THz experiment demonstrated a good potential of a robust, table-top system for generation of a narrow bandwidth THz radiation. This setup can be considered as a prototype of a compact, laser-free, flexible source capable of generation of long trains of Sub-THz and THz pulses with repetition rates not available with laser-driven sources.« less

  19. Commissioning Results of the 2nd 3.5 Cell SRF Gun for ELBE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, A; Freitag, M; Murcek, Petr

    As in 2007 the first 3.5 cell superconducting radio frequency (SRF) gun was taken into operation, it turned out that the specified performance has not been achieved. However, to demonstrate the full potential of this new type of electron source, a second and slightly modified SRF gun II was built in collaboration with Thomas Jefferson National Accelerator Facility (TJNAF). We will report on commissioning and first results of the new gun, which includes in particular the characterization of the most important RF properties as well as their comparison with previous vertical test results.

  20. Focussed ion beam thin sample microanalysis using a field emission gun electron probe microanalyser

    NASA Astrophysics Data System (ADS)

    Kubo, Y.

    2018-01-01

    Field emission gun electron probe microanalysis (FEG-EPMA) in conjunction with wavelength-dispersive X-ray spectrometry using a low acceleration voltage (V acc) allows elemental analysis with sub-micrometre lateral spatial resolution (SR). However, this degree of SR does not necessarily meet the requirements associated with increasingly miniaturised devices. Another challenge related to performing FEG-EPMA with a low V acc is that the accuracy of quantitative analyses is adversely affected, primarily because low energy X-ray lines such as the L- and M-lines must be employed and due to the potential of line interference. One promising means of obtaining high SR with FEG-EPMA is to use thin samples together with high V acc values. This mini-review covers the basic principles of thin-sample FEG-EPMA and describes an application of this technique to the analysis of optical fibres. Outstanding issues related to this technique that must be addressed are also discussed, which include the potential for electron beam damage during analysis of insulating materials and the development of methods to use thin samples for quantitative analysis.

  1. Performance of a first generation X-band photoelectron rf gun

    DOE PAGES

    Limborg-Deprey, C.; Adolphsen, C.; McCormick, D.; ...

    2016-05-04

    Building more compact accelerators to deliver high brightness electron beams for the generation of high flux, highly coherent radiation is a priority for the photon science community. A relatively straightforward reduction in footprint can be achieved by using high-gradient X-band (11.4 GHz) rf technology. To this end, an X-band injector consisting of a 5.5 cell rf gun and a 1-m long linac has been commissioned at SLAC. It delivers an 85 MeV electron beam with peak brightness somewhat better than that achieved in S-band photoinjectors, such as the one developed for the Linac Coherent Light Source (LCLS). The X-band rfmore » gun operates with up to a 200 MV/m peak field on the cathode, and has been used to produce bunches of a few pC to 1.2 nC in charge. Notably, bunch lengths as short as 120 fs rms have been measured for charges of 5 pC (~3×10 7 electrons), and normalized transverse emittances as small as 0.22 mm-mrad have been measured for this same charge level. Bunch lengths as short as 400 (250) fs rms have been achieved for electron bunches of 100 (20) pC with transverse normalized emittances of 0.7 (0.35) mm-mrad. As a result, we report on the performance and the lessons learned from the operation and optimization of this first generation X-band gun.« less

  2. Performance of a first generation X-band photoelectron rf gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C.; Adolphsen, C.; McCormick, D.

    Building more compact accelerators to deliver high brightness electron beams for the generation of high flux, highly coherent radiation is a priority for the photon science community. A relatively straightforward reduction in footprint can be achieved by using high-gradient X-band (11.4 GHz) rf technology. To this end, an X-band injector consisting of a 5.5 cell rf gun and a 1-m long linac has been commissioned at SLAC. It delivers an 85 MeV electron beam with peak brightness somewhat better than that achieved in S-band photoinjectors, such as the one developed for the Linac Coherent Light Source (LCLS). The X-band rfmore » gun operates with up to a 200 MV/m peak field on the cathode, and has been used to produce bunches of a few pC to 1.2 nC in charge. Notably, bunch lengths as short as 120 fs rms have been measured for charges of 5 pC (~3×10 7 electrons), and normalized transverse emittances as small as 0.22 mm-mrad have been measured for this same charge level. Bunch lengths as short as 400 (250) fs rms have been achieved for electron bunches of 100 (20) pC with transverse normalized emittances of 0.7 (0.35) mm-mrad. As a result, we report on the performance and the lessons learned from the operation and optimization of this first generation X-band gun.« less

  3. Gun shows across a multistate American gun market: observational evidence of the effects of regulatory policies.

    PubMed

    Wintemute, Garen J

    2007-06-01

    To describe gun shows and assess the impact of increased regulation on characteristics linked to their importance as sources of guns used in crime. Cross-sectional, observational. Data were collected at a structured sample of 28 gun shows in California, which regulates these events and prohibits undocumented private party gun sales; and in Arizona, Nevada, Texas and Florida-all leading sources of California's crime guns--where these restrictions do not exist. Size of shows, measured by numbers of gun vendors and people in attendance; number and nature of guns for sale by gun vendors; measures of private party gun sales and illegal surrogate ("straw") gun purchases. Shows in comparison states were larger, but the number of attendees per gun vendor was higher in California. None of these differences was statistically significant. Armed attendees were more common in other states (median 5.7%, interquartile range (IQR) 3.9-10.0%) than in California (median 1.1%, IQR 0.5-2.2%), p = 0.0007. Thirty percent of gun vendors both in California and elsewhere were identifiable as licensed firearm retailers. There were few differences in the types or numbers of guns offered for sale; vendors elsewhere were more likely to sell assault weapons (34.9% and 13.3%, respectively; p = 0.001). Straw purchases were more common in the comparison states (rate ratio 6.6 (95% CI 0.9 to 49.1), p = 0.06). California's regulatory policies were associated with a decreased incidence of anonymous, undocumented gun sales and illegal straw purchases at gun shows. No significant adverse effects of these policies were observed.

  4. High voltage breakdown phenomena in RF window, electron gun and RF cavities in 250 kW CW C band Klystron and their preventive measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamba, O.S.; Badola, Richa; Baloda, Suman

    The paper describes voltage break down phenomenon and preventive measures in components of 250 KW CW, C band Klystron under development at CEERI Pilani. The Klystron operates at a beam voltage of 50 kV and delivers 250 kW RF power at 5 GHz frequency. The Klystron consists of several key components and regions, which are subject to high electrical stress. The most important regions of electrical breakdown are electron gun, the RF ceramic window and output cavity gap area. In the critical components voltage breakdown considered at design stage by proper gap and other techniques. All these problems discussed, asmore » well as solution to alleviate this problem. The electron gun consists basically of cathode, BFE and anode. The cathode is operated at a voltage of 50 kV. In order to maintain the voltage standoff between cathode and anode a high voltage alumina seal and RF window have been designed developed and successfully used in the tube. (author)« less

  5. Upgrade possibilities for continuous wave rf electron guns based on room-temperature very high frequency technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sannibale, F.; Filippetto, D.; Johnson, M.

    The past decade was characterized by an increasing scientific demand for extending towards higher repetition rates (MHz class and beyond) the performance of already operating lower repetition rate accelerator-based instruments such as x-ray free electron lasers (FELs) and ultrafast electron diffraction (UED) and microscopy (UEM) instruments. Such a need stimulated a worldwide spread of a vibrant R & D activity targeting the development of high-brightness electron sources capable of operating at these challenging rates. Among the different technologies pursued, rf guns based on room-temperature structures resonating in the very high frequency (VHF) range (30-300 MHz) and operating in continuous wavemore » successfully demonstrated in the past few years the targeted brightness and reliability. Nonetheless, recently proposed upgrades for x-ray FELs and the always brightness-frontier applications such as UED and UEM are now requiring a further step forward in terms of beam brightness in electron sources. Here, we present a few possible upgrade paths that would allow one to extend, in a relatively simple and cost-effective way, the performance of the present VHF technology to the required new goals.« less

  6. Upgrade possibilities for continuous wave rf electron guns based on room-temperature very high frequency technology

    DOE PAGES

    Sannibale, F.; Filippetto, D.; Johnson, M.; ...

    2017-11-27

    The past decade was characterized by an increasing scientific demand for extending towards higher repetition rates (MHz class and beyond) the performance of already operating lower repetition rate accelerator-based instruments such as x-ray free electron lasers (FELs) and ultrafast electron diffraction (UED) and microscopy (UEM) instruments. Such a need stimulated a worldwide spread of a vibrant R & D activity targeting the development of high-brightness electron sources capable of operating at these challenging rates. Among the different technologies pursued, rf guns based on room-temperature structures resonating in the very high frequency (VHF) range (30-300 MHz) and operating in continuous wavemore » successfully demonstrated in the past few years the targeted brightness and reliability. Nonetheless, recently proposed upgrades for x-ray FELs and the always brightness-frontier applications such as UED and UEM are now requiring a further step forward in terms of beam brightness in electron sources. Here, we present a few possible upgrade paths that would allow one to extend, in a relatively simple and cost-effective way, the performance of the present VHF technology to the required new goals.« less

  7. Coaxial-gun design and testing for the PLX- α Project

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. Douglas; Brockington, Samuel; Case, Andrew; Cruz, Edward; Luna, Marco; Langendorf, Samuel

    2016-10-01

    We describe the Alpha coaxial gun designed for a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). The guns operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The latest design iteration incorporates a faster more robust gas valve, an improved electrode contour, a custom 600- μF, 5-kV pfn, and six inline sparkgap switches operated in parallel. The switch and pfn are mounted directly to the back of the gun and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. We provide a brief overview of the design choices, the projected performance over the parameter ranges mentioned above, and experimental results from testing of the PLX- α coaxial gun. This work supported by the ARPA-E ALPHA Program.

  8. Direct morphological comparison of vacuum plasma sprayed and detonation gun sprayed hydroxyapatite coatings for orthopaedic applications.

    PubMed

    Gledhill, H C; Turner, I G; Doyle, C

    1999-02-01

    Hydroxyapatite coatings on titanium substrates were produced using two thermal spray techniques vacuum plasma spraying and detonation gun spraying. X-ray diffraction was used to compare crystallinity and residual stresses in the coatings. Porosity was measured using optical microscopy in conjunction with an image analysis system. Scanning electron microscopy and surface roughness measurements were used to characterise the surface morphologies of the coatings. The vacuum plasma sprayed coatings were found to have a lower residual stress, a higher crystallinity and a higher level of porosity than the detonation gun coatings. It is concluded that consideration needs to be given to the significance of such variations within the clinical context.

  9. Gun carrying by high school students in Boston, MA: does overestimation of peer gun carrying matter?

    PubMed

    Hemenway, David; Vriniotis, Mary; Johnson, Renee M; Miller, Matthew; Azrael, Deborah

    2011-10-01

    This paper investigates: (1) whether high school students overestimate gun carrying by their peers, and (2) whether those students who overestimate peer gun carrying are more likely to carry firearms. Data come from a randomly sampled survey conducted in 2008 of over 1,700 high school students in Boston, MA. Over 5% of students reported carrying a gun, 9% of boys and 2% of girls. Students substantially overestimated the percentage of their peers who carried guns; the likelihood that a respondent carried a gun was strongly associated with their perception of the level of peer gun carrying. Most respondents believed it was easier for other youth to obtain guns than it was for them. Social marketing campaigns designed to lower young people's perceptions about the prevalence of peer gun carrying may be a promising strategy for reducing actual gun carrying among youth. Copyright © 2010 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  10. Goods for Guns--the use of a gun buyback as an injury prevention/community education tool.

    PubMed

    McGuire, Margaret; Manno, Mariann; Rook, Allison; Maranda, Louise; Renaud, Elizabeth; DeRoss, Anthony; Hirsh, Michael

    2011-11-01

    US children aged between 5 years and 14 years have a rate of gun-related homicide 17 times higher and a rate of gun-related suicide and unintentional firearm injury 10 times higher than other developed countries. Gun buyback programs have been criticized as ineffective interventions in decreasing violence. The Injury Free Coalition for Kids-Worcester (IFCK-W) Goods for Guns buyback is a multipronged approach to address these concerns and to reduce the number of firearms in the community. The IFCK-W buyback program is funded by corporate sponsors, grants, and individual donations. Citizens are instructed to transport guns, ammunition, and weapons safely to police headquarters on two Saturdays in December. Participants are guaranteed anonymity by the District Attorney's office and receive gift certificates for operable guns. Trained volunteers administer an anonymous survey to willing participants. Individuals who disclose having unsafely stored guns remaining at home receive educational counseling and trigger locks. Guns and ammunition are destroyed at a later time in a gun crushing ceremony. Since 2002, 1,861 guns (444 rifle/shotgun, 738 pistol/revolver, and 679 automatic/semiautomatic) have been collected at a cost of $99,250 (average, $53/gun). Seven hundred ten people have surrendered firearms, 534 surveys have been administered, and ≈ 75 trigger locks have been distributed per year. IFCK-W Goods for Guns is a relatively inexpensive injury prevention model program that removes unwanted firearms from homes, raises community awareness about gun safety, and provides high-risk individuals with trigger locks and educational counseling.

  11. Simplified pipe gun

    NASA Astrophysics Data System (ADS)

    Sørensen, H.; Nordskov, A.; Sass, B.; Visler, T.

    1987-12-01

    A simplified version of a deuterium pellet gun based on the pipe gun principle is described. The pipe gun is made from a continuous tube of stainless steel and gas is fed in from the muzzle end only. It is indicated that the pellet length is determined by the temperature gradient along the barrel right outside the freezing cell. Velocities of around 1000 m/s with a scatter of ±2% are obtained with a propellant gas pressure of 40 bar.

  12. Gun shows across a multistate American gun market: observational evidence of the effects of regulatory policies

    PubMed Central

    Wintemute, Garen J

    2007-01-01

    Objective To describe gun shows and assess the impact of increased regulation on characteristics linked to their importance as sources of guns used in crime. Design Cross‐sectional, observational. Subjects Data were collected at a structured sample of 28 gun shows in California, which regulates these events and prohibits undocumented private party gun sales; and in Arizona, Nevada, Texas and Florida—all leading sources of California's crime guns—where these restrictions do not exist. Main outcome measures Size of shows, measured by numbers of gun vendors and people in attendance; number and nature of guns for sale by gun vendors; measures of private party gun sales and illegal surrogate (“straw”) gun purchases. Results Shows in comparison states were larger, but the number of attendees per gun vendor was higher in California. None of these differences was statistically significant. Armed attendees were more common in other states (median 5.7%, interquartile range (IQR) 3.9–10.0%) than in California (median 1.1%, IQR 0.5–2.2%), p = 0.0007. Thirty percent of gun vendors both in California and elsewhere were identifiable as licensed firearm retailers. There were few differences in the types or numbers of guns offered for sale; vendors elsewhere were more likely to sell assault weapons (34.9% and 13.3%, respectively; p = 0.001). Straw purchases were more common in the comparison states (rate ratio 6.6 (95% CI 0.9 to 49.1), p = 0.06). Conclusions California's regulatory policies were associated with a decreased incidence of anonymous, undocumented gun sales and illegal straw purchases at gun shows. No significant adverse effects of these policies were observed. PMID:17567968

  13. Gun Attitudes and Fear of Crime.

    ERIC Educational Resources Information Center

    Heath, Linda; Weeks, Kyle; Murphy, Marie Mackay

    1997-01-01

    Using three studies, examined the relationship between attitudes toward guns and fear of crime. Findings indicate a connection between fear of crime and attitudes toward guns: people higher in fear of crime favored gun control. Results also established a relationship between stereotypical beliefs about gun victims and support for gun control. (RJM)

  14. The case for moderate gun control.

    PubMed

    DeGrazia, David

    2014-03-01

    In addressing the shape of appropriate gun policy, this essay assumes for the sake of discussion that there is a legal and moral right to private gun ownership. My thesis is that, against the background of this right, the most defensible policy approach in the United States would feature moderate gun control. The first section summarizes the American gun control status quo and characterizes what I call "moderate gun control." The next section states and rebuts six leading arguments against this general approach to gun policy. The section that follows presents a positive case for moderate gun control that emphasizes safety in the home and society as well as rights whose enforcement entails some limits or qualifications on the right to bear arms. A final section shows how the recommended gun regulations address legitimate purposes, rather than imposing arbitrary restrictions on gun rights, and offers concluding reflections.

  15. Magnetron injection gun for a broadband gyrotron backward-wave oscillator

    NASA Astrophysics Data System (ADS)

    Yuan, C. P.; Chang, T. H.; Chen, N. C.; Yeh, Y. S.

    2009-07-01

    The magnetron injection gun is capable of generating relativistic electron beam with high velocity ratio and low velocity spread for a gyrotron backward-wave oscillator (gyro-BWO). However, the velocity ratio (α) varies drastically against both the magnetic field and the beam voltage, which significantly limits the tuning bandwidth of a gyro-BWO. This study remedies this drawback by adding a variable trim field to adjust the magnetic compression ratio when changing the operating conditions. Theoretical results obtained by employing a two-dimensional electron gun code (EGUN) demonstrate a constant velocity ratio of 1.5 with a low axial velocity spread of 6% from 3.4-4.8 Tesla. These results are compared with a three-dimensional particle-tracing code (computer simulation technology, CST). The underlying physics for constant α will be discussed in depth.

  16. Gun violence in Americans' social network during their lifetime.

    PubMed

    Kalesan, Bindu; Weinberg, Janice; Galea, Sandro

    2016-12-01

    The overall burden of gun violence death and injury in the US is now well understood. However, no study has shown the extent to which gun violence is associated with the individual lives of Americans. We used fatal and non-fatal gun injury rates in 2013 from Centers for Disease Control and Prevention's Web-based Injury Statistics Query and Reporting System (WISQARS) and generally accepted estimates about the size of an American's social network to determine the likelihood that any given person will know someone in their personal social network who is a victim of gun violence during their lifetime. We derived estimates in the overall population and among racial/ethnic groups and by gun-injury intent. The likelihood of knowing a gun violence victim within any given personal network over a lifetime is 99.85% (99.8% to 99.9%). The likelihood among non-Hispanic white, black, Hispanic and other race Americans were 97.1%, 99.9%, 99.5% and 88.9% respectively. Nearly all Americans of all racial/ethnic groups are likely to know a victim of gun violence in their social network during their lifetime. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. BEAM DYNAMICS SIMULATIONS FOR A DC GUN BASED INJECTOR FOR PERL.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ZHOU,F.; BEN-ZVI,I.; WANG,X.J.

    2001-06-18

    The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL) is considering an upgrade based on the Photoinjected Energy Recovering Linac (PERL). The various injector schemes for this machine are being extensively investigated at BNL. One of the possible options is photocathode DC gun. The schematic layout of a PERL DC gun based injector and its preliminary beam dynamics are presented in this paper. The transverse and longitudinal emittance of photo-electron beam were optimized for a DC field 500 kV.

  18. Non-Uniform Cathode Emission Studies of a MIG Gun

    NASA Astrophysics Data System (ADS)

    Marchewka, C. D.; Shapiro, M. A.; Sirigiri, J. R.; Temkin, R. J.

    2004-11-01

    We present the initial results of the modeling of the effect of emission non-uniformity in 96 kV, 40 A Magnetron Injection Gun (MIG) of a 1.5 MW 110 GHz gyrotron using a 3D gun simulation code. The azimuthal emission nonuniformity can lead to increased mode competition and an overall decreased efficiency of the device [1]. The electron beam is modeled from the cathode to a downstream position where the velocity spread saturates using the AMAZE 3D suite of codes. After bench marking the results of the 3D code with 2D codes such as TRAK2D and EGUN, the emitter was modified to simulate asymmetric emission from the cathode to gain an understanding into the effects of inhomogeneous beam current density on the velocity spread and pitch factor of the electron beam. [1] G. S. Nusinovich, A.N. Vlasov, M. Botton, T. M. Antonsen, Jr., S. Cauffman, K. Felch, ``Effect of the azimuthal inhomogeneity of electron emission on gyrotron operation,'' Phys. Plasmas, vol. 8, no. 7, pp. 3473-3479, 2001

  19. The PLX- α Plasma Guns: Progress and Plans

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. D.; Brockington, S.; Case, A.; Cruz, E.; Luna, M.; Thio, Y. C. Francis; LANL PLX-α Team

    2017-10-01

    The ALPHA coaxial plasma guns are being developed to support a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). Seven complete guns have been delivered to LANL with 6 guns currently undergoing simultaneous test firings on PLX. The guns are designed to operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured coaxial gap to suppress the blow-by instability. Optimizing parameter scans performed at HyperV have achieved : 4 mg at >50 km/s and length of 10 cm. Peak axial density 30 cm from the muzzle is 2 ×1016 cm-3. We will provide an overview of the experimental results, along with plans for further improvements in reliability, maintainability, fabricability, and plasma jet performance, with the latter focused on further improvements in the fast gas valve and the ignitors. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  20. Cusp Guns for Helical-Waveguide Gyro-TWTs of a High-Gain High-Power W-Band Amplifier Cascade

    NASA Astrophysics Data System (ADS)

    Manuilov, V. N.; Samsonov, S. V.; Mishakin, S. V.; Klimov, A. V.; Leshcheva, K. A.

    2018-02-01

    The evaluation, design, and simulations of two different electron guns generating the beams for W-band second cyclotron harmonic gyro-TWTs forming a high-gain powerful amplifier cascade are presented. The optimum configurations of the systems creating nearly axis-encircling electron beams having velocity pitch-factor up to 1.5, voltage/current of 40 kV/0.5 A, and 100 kV/13 A with acceptable velocity spreads have been found and are presented.

  1. Coaxial Plasma Gun Development for the ARPA-E PLX- α Project

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. Douglas; Case, Andrew; Brockington, Samuel

    2015-11-01

    We describe the renewed effort to design and build coaxial plasma guns appropriate for a scaling study of spherically imploding plasma liners as a standoff magneto-inertial-fusion driver under the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. HyperV joins LANL, UAH, UNM, BNL, and Tech-X to develop, build, operate and analyze a 60 plasma gun experiment using the existing PLX facility at LANL. The guns will be designed to operate over a scaling range of operating parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 1016 -1017 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each gun is planned to incorporate contoured gaps, fast dense gas injection and triggering, and innovative integral sparkgap switching and pfn configurations to reduce inductance, cost, and complexity, and to increase efficiency and system reliability. We will describe the overall design approach for the guns and pulsed power systems. This work supported by the ARPA-E ALPHA Program.

  2. Commissioning of the 112 MHz SRF Gun and 500 MHz bunching cavities for the CeC PoP Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belomestnykh, S.; Ben-Zvi, I.; Brutus, J. C.

    The Coherent electron Cooling Proof-of-Principle (CeC PoP) experiment at BNL includes a short electron linac. During Phase 1, a 112 MHz superconducting RF photo-emission gun and two 500 MHz normal conducting bunching cavities were installed and are under commissioning. The paper describes the Phase1 linac layout and presents commissioning results for the cavities and associated RF, cryogenic and other sub-systems

  3. The NSCL electron beam ion trap for the reacceleration of rare isotopes coming to life: first extraction tests with a high-current electron gun.

    PubMed

    Schwarz, S; Bollen, G; Johnson, M; Kester, O; Kostin, M; Ottarson, J; Portillo, M; Wilson, C; López-Urrutia, J R Crespo; Dilling, J

    2010-02-01

    NSCL is currently constructing the ReA3 reaccelerator, which will accelerate rare isotopes obtained from gas stopping of fast-fragment beams to energies of up to 3 MeV/u for uranium and higher for lighter ions. A high-current charge breeder, based on an electron beam ion trap (EBIT), has been chosen as the first step in the acceleration process, as it has the potential to efficiently produce highly charged ions in a single charge state. These ions are fed into a compact linear accelerator consisting of a radio frequency quadrupole structure and superconducting cavities. The NSCL EBIT has been fully designed with most of the parts constructed. The design concept of the EBIT and results from initial commissioning tests of the electron gun and collector with a temporary 0.4 T magnet are presented.

  4. Direct launch using the electric rail gun

    NASA Technical Reports Server (NTRS)

    Barber, J. P.

    1983-01-01

    The concept explored involves using a large single stage electric rail gun to achieve orbital velocities. Exit aerodynamics, launch package design and size, interior ballistics, system and component sizing and design concepts are treated. Technology development status and development requirements are identified and described. The expense of placing payloads in Earth orbit using conventional chemical rockets is considerable. Chemical rockets are very inefficient in converting chemical energy into payload kinetic energy. A rocket motor is relatively expensive and is usually expended on each launch. In addition specialized and expensive forms of fuel are required. Gun launching payloads directly to orbit from the Earth's surface is a possible alternative. Guns are much more energy efficient than rockets. The high capital cost of the gun installation can be recovered by reusing it over and over again. Finally, relatively inexpensive fuel and large quantities of energy are readily available to a fixed installation on the Earth's surface.

  5. Gun Violence Following Inpatient Psychiatric Treatment: Offense Characteristics, Sources of Guns, and Number of Victims.

    PubMed

    Kivisto, Aaron J

    2017-10-01

    This study presents data on the relative contribution to gun violence by people with a history of inpatient psychiatric treatment and on federal efforts to deter presumptively dangerous persons from obtaining firearms, information useful for analyzing the potential public health benefits of gun policies targeting people with serious mental illness. The study also estimates the reduction in gun violence victims that would be expected if individuals with a previous psychiatric hospitalization were prohibited from purchasing firearms. Data from 838 violent gun offenders from a nationally representative sample of state prison inmates were analyzed. Those with and without a history of psychiatric hospitalization were compared on a range of offense characteristics, including relationship to the victim, number of victims, location of the offense, and source of firearms. Inmates with a history of hospitalization constituted 12% of all violent gun offenders and accounted for 13% of the sample's victims. They were less likely than those without a previous hospitalization to victimize strangers (odds ratio=.52) and were no more likely to commit gun violence in public or to have multiple victims. Among those with previous hospitalizations, 78% obtained guns from sources not subject to federal background checks. Of the total 1,041 victims of gun violence, only 3% were victimized by participants with a history of hospitalization who obtained guns from currently regulated sources. Prohibiting all individuals with a history of psychiatric hospitalization from purchasing firearms, absent expanded background checks, was estimated to reduce the number of gun violence victims by only 3%.

  6. From gun politics to self-defense politics: a feminist critique of the great gun debate.

    PubMed

    Carlson, Jennifer D

    2014-03-01

    This article calls attention to a problematic binary produced by public debates surrounding gun rights and gun control-namely, that women must choose armed self-protection or no self-protection at all. I argue that both anti- and pro-gun discourses, drawing on and reproducing race and class privileges, use assumptions about women's physical inferiority to further their agendas. I highlight how both sides have used guns as the proxy for self-defense and conclude by calling for a shift in public discourse to focus on the broader question of the right to self-defense rather than the narrower question of gun rights.

  7. Unusual Case of Suicide With a Modified Trap Gun.

    PubMed

    Vadysinghe, Amal; Dassanayake, Prasanna; Wickramasinghe, Medhani

    2017-06-01

    Trap gun is an illegal, locally manufactured gun with a basic trip system used to hunt wild animals. The body of a 28-year-old man was found in the jungle in supine position with both legs apart. A trap gun was between the legs pointing toward the cranial side of the body. It had 2 free wires that were not connected together. There was no evidence of foul play.The body had a single-entry wound (2.5-cm diameter) in the anterior chest, with blackening, burning, and tattooing. Six metal particles and nylon clothing material were embedded into soft tissue. No exit wound was found. Toxicology analysis reported an alcohol level of 72 mg/dL. The cause of death was multiple shrapnel injury to the chest at close to intermediate range by a single discharge from a trap gun. Circumstance was concluded as suicide.Ballistic and firearm experts opined that an illegal, manually operated, battery-powered ignition device was used to ignite the gun powder. We report the first case of suicide by a modified trap gun in literature.

  8. The life cycle of crime guns: a description based on guns recovered from young people in California.

    PubMed

    Wintemute, Garen J; Romero, Michael P; Wright, Mona A; Grassel, Kevin M

    2004-06-01

    We describe the life cycle of crime guns recovered from young people-the movement of those guns from manufacture to criminal use-and identify associations between the characteristics of those guns and their possessors, purchasers, sellers, and places of origin. This is a cross-sectional study of data from gun ownership tracing records compiled by the Bureau of Alcohol, Tobacco, Firearms and Explosives for 2,121 crime guns recovered in California from persons younger than 25 years and traced in 1999. Purchaser and seller data for handguns were updated when possible by linking to California handgun sales records. The 2,121 traced guns were recovered from 1,717 young people. Guns recovered from persons aged 21 to 24 years were most frequently also purchased by persons aged 21 to 24 years; those recovered from persons younger than 18 years were most often purchased by persons aged 45 years or older. Small-caliber handguns made up 41.0% of handguns recovered from persons younger than 18 years but 25.2% of handguns recovered from persons aged 21 to 24 years. The median time from sale to recovery (commonly called time to crime) for all guns was 6.4 years (interquartile range 2.7 to 12.4 years). A time to crime of less than 3 years, suggesting deliberate gun trafficking, was observed for 17.3% of guns recovered from persons younger than 18 years but 34.6% of guns recovered from persons aged 21 to 24 years. Ten retailers who sold 10 or more traced guns accounted for 13.1% of all guns traced to a retailer. Handguns whose purchaser and possessor were the same person were more likely than others to be large-caliber semiautomatic pistols (29.3% and 11.7%, respectively); their median time to crime was 0.2 years (69 days). Analysis of crime-gun ownership traces reveals patterns that may help refine gun violence prevention efforts and render them more effective.

  9. Modeling internal ballistics of gas combustion guns.

    PubMed

    Schorge, Volker; Grossjohann, Rico; Schönekess, Holger C; Herbst, Jörg; Bockholdt, Britta; Ekkernkamp, Axel; Frank, Matthias

    2016-05-01

    Potato guns are popular homemade guns which work on the principle of gas combustion. They are usually constructed for recreational rather than criminal purposes. Yet some serious injuries and fatalities due to these guns are reported. As information on the internal ballistics of homemade gas combustion-powered guns is scarce, it is the aim of this work to provide an experimental model of the internal ballistics of these devices and to investigate their basic physical parameters. A gas combustion gun was constructed with a steel tube as the main component. Gas/air mixtures of acetylene, hydrogen, and ethylene were used as propellants for discharging a 46-mm caliber test projectile. Gas pressure in the combustion chamber was captured with a piezoelectric pressure sensor. Projectile velocity was measured with a ballistic speed measurement system. The maximum gas pressure, the maximum rate of pressure rise, the time parameters of the pressure curve, and the velocity and path of the projectile through the barrel as a function of time were determined according to the pressure-time curve. The maximum gas pressure was measured to be between 1.4 bar (ethylene) and 4.5 bar (acetylene). The highest maximum rate of pressure rise was determined for hydrogen at (dp/dt)max = 607 bar/s. The muzzle energy was calculated to be between 67 J (ethylene) and 204 J (acetylene). To conclude, this work provides basic information on the internal ballistics of homemade gas combustion guns. The risk of injury to the operator or bystanders is high, because accidental explosions of the gun due to the high-pressure rise during combustion of the gas/air mixture may occur.

  10. 77 FR 37834 - Revocation of Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-25

    ... Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns Not Intended for Use... compliance than our existing regulations pertaining to caps intended for use with toy guns and toy guns not... regulations pertaining to caps intended for use with toy guns and toy guns not intended for use with caps...

  11. High current polarized electron source for future eRHIC

    NASA Astrophysics Data System (ADS)

    Wang, Erdong

    2018-05-01

    The high current and high bunch charge polarized electron source is essential for cost reduction of Linac-Ring (L-R) eRHIC. In the baseline design, electron beam from multiple guns (probably 4-8) will be combined using deflection plates or accumulate ring. Each gun aims to deliver electron beam with 10 mA average current and 5.3 nC bunch charge. With total 50 mA and 5.3 nC electron beam, this beam combining design could use for generating positron too. The gun has been designed, fabricated and expected to start commissioning by the mid of this year. In this paper, we will present the DC gun design parameters and beam combine schemes. Also, we will describe the details of gun design and the strategies to demonstrate high current high charge polarized electron beam from this source.

  12. NPS Gas Gun for Planar Impact Studies

    NASA Astrophysics Data System (ADS)

    Cheong Ho, Chien; Hixson, Robert

    2009-11-01

    The Naval Postgraduate School (NPS) commissioned a Gas Gun for shock wave studies on 9^th October 2009, by performing the first experiment. The Gas Gun is the key element of NPS Shock Wave Research Program within the Physics Department, where well-characterized planar impacts are essential for obtaining high quality data, to characterize a solid material. This first experiment was very successful, and returned key data on the quality of the impact conditions created. The Gas Gun is designed by SANDIA NATIONAL LABORATORIES, and the NPS spent twelve months fabricating the components of the Gas Gun and six months assembling the Gas Gun. Three inch projectile are launched at velocities up to 0.5 km/s, creating high pressure and temperature states that can be used to characterize the fundamental response of relevant materials to dynamic loading. The projectile is launched from a `wrap around' gas breech where helium gas is pressurized to relatively low pressure. This gas is used to accelerate the projectile down a 3m barrel. Upon impact, the speed of the projectile and the flatness of the impact is measured, via a stepped circular pin array circuit. The next stage of development for the Gas Gun is to integrate a Velocity Interferometer System for Any Reflector (VISAR). The VISAR sees all the waves that flow through the target plate as a result of the impact. This is a key diagnostic for determining material properties under dynamic loading conditions.

  13. Effects of undercover police stings of gun dealers on the supply of new guns to criminals

    PubMed Central

    Webster, D W; Bulzacchelli, M T; Zeoli, A M; Vernick, J S

    2006-01-01

    Objective To assess the effects of undercover police stings and lawsuits against gun dealers suspected of facilitating illegal gun sales in three US cities (Chicago, Detroit, Gary) on the flow of new firearms to criminals. Methods An interrupted time series design and negative binomial regression analyses were used to test for temporal change in the recovery of guns used in crimes within one year of retail sale in both intervention and comparison cities. Results The stings were associated with an abrupt 46.4% reduction in the flow of new guns to criminals in Chicago (95% confidence interval, −58.6% to −30.5%), and with a gradual reduction in new crime guns recovered in Detroit. There was no significant change associated with the stings in Gary, and no change in comparison cities that was coincident with the stings in Chicago and Detroit. Conclusions The announcement of police stings and lawsuits against suspect gun dealers appeared to have reduced the supply of new guns to criminals in Chicago significantly, and may have contributed to beneficial effects in Detroit. Given the important role that gun stores play in supplying guns to criminals in the US, further efforts of this type are warranted and should be evaluated. PMID:16887943

  14. Gun trauma and ophthalmic outcomes.

    PubMed

    Chopra, N; Gervasio, K A; Kalosza, B; Wu, A Y

    2018-04-01

    PurposeThis retrospective cohort study assesses the visual outcomes of patients who survive gunshot wounds to the head.MethodsThe Elmhurst City Hospital Trauma Registry and Mount Sinai Data Warehouse were queried for gun trauma resulting in ocular injury over a 16-year period. Thirty-one patients over 16 years of age were found who suffered a gunshot wound to the head and resultant ocular trauma: orbital fracture, ruptured globe, foreign body, or optic nerve injury. Gun types included all firearms and air guns. Nine patients were excluded due to incorrect coding or unavailable charts. Statistical analysis was performed using a simple bivariate analysis (χ 2 ).ResultsOf the 915 victims of gun trauma to the head, 27 (3.0%) sustained ocular injuries. Of the 22 patients whose records were accessible, 18 survived. Eight of the 18 surviving patients (44%) suffered long-term visual damage, defined as permanent loss of vision in at least one eye to the level of counting fingers or worse. Neither location of injury (P=0.243), nor type of gun used (P=0.296), nor cause of gun trauma (P=0.348) predicted visual loss outcome. The Glasgow Coma Scale eye response score on arrival to the hospital also did not predict visual loss outcome (P=0.793).ConclusionThere has been a dearth of research into gun trauma and even less research on the visual outcomes following gun trauma. Our study finds that survivors of gun trauma to the head suffer long-term visual damage 44% of the time after injury.

  15. Preventing Clogging In A Vacuum Plasma Spray Gun

    NASA Technical Reports Server (NTRS)

    Krotz, Phillip D.; Daniel, Ronald L., Jr.; Davis, William M.

    1994-01-01

    Modification of powder-injection ports enables lengthy, high-temperature deposition operations. Graphite inserts prevent clogging of ports through which copper powder injected into vacuum plasma spray (VPS) gun. Graphite liners eliminate need to spend production time refurbishing VPS gun, reducing cost of production and increasing productivity. Concept also applied to other material systems used for net-shape fabrication via VPS.

  16. Simulations of S-band RF gun with RF beam control

    NASA Astrophysics Data System (ADS)

    Barnyakov, A. M.; Levichev, A. E.; Maltseva, M. V.; Nikiforov, D. A.

    2017-08-01

    The RF gun with RF control is discussed. It is based on the RF triode and two kinds of the cavities. The first cavity is a coaxial cavity with cathode-grid assembly where beam bunches are formed, the second one is an accelerating cavity. The features of such a gun are the following: bunched and relativistic beams in the output of the injector, absence of the back bombarding electrons, low energy spread and short length of the bunches. The scheme of the injector is shown. The electromagnetic field simulation and longitudinal beam dynamics are presented. The possible using of the injector is discussed.

  17. Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agustsson, R.; Boucher, S.; Finn, O.

    A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. Themore » system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.« less

  18. Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

    DOE PAGES

    Agustsson, R.; Boucher, S.; Finn, O.; ...

    2015-01-01

    A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. Themore » system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.« less

  19. Loaded: Gun involvement among opioid users.

    PubMed

    Stein, Michael D; Kenney, Shannon R; Anderson, Bradley J; Bailey, Genie L

    2018-06-01

    Despite ample research examining how alcohol use relates to gun involvement, little is known about the relationship between opioids and gun involvement. In the current study, we examined correlates of gun possession, accessibility, and related behaviors in an opioid dependent sample. Between October 2016 and April 2017, we surveyed persons entering a brief, inpatient opioid detoxification (n = 386) and 51 contemporaneous persons seeking alcohol detoxification at the same facility in Massachusetts and recorded their lifetime experiences with gun involvement. Participants averaged 33 years of age, 74% were male, 83% were White, and 64% had a history of incarceration. Opioid users had significantly higher rates of gun involvement than persons in alcohol detoxification; for example, 31.3% (vs. 3.9%) had carried a gun for protection, 45.1% (vs. 25.5%) had been threatened with a gun, and 13.8% (vs. 2.0%) had shot at another person. Among persons misusing opioids, male and non-White respondents, and those with a history of incarceration or poorer self-control reported greater gun involvement. Opioid users, both men and women, lead gun-involved lives. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Nonfatal Gun Use in Intimate Partner Violence: A Systematic Review of the Literature.

    PubMed

    Sorenson, Susan B; Schut, Rebecca A

    2016-09-14

    Guns figure prominently in the homicide of women by an intimate partner. Less is known, however, about their nonfatal use against an intimate partner. Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we searched eight electronic databases and identified 10 original research articles that reported the prevalence of the nonfatal use of firearms against an intimate partner. Results indicate that (1) there is relatively little research on the subject of intimate partners' nonfatal gun use against women. (2) The number of U.S. women alive today who have had an intimate partner use a gun against them is substantial: About 4.5 million have had an intimate partner threaten them with a gun and nearly 1 million have been shot or shot at by an intimate partner. Whether nonfatal gun use is limited to the extreme form of abuse (battering) or whether it occurs in the context of situational violence remains to be seen. Regardless, when it comes to the likely psychological impact, it may be a distinction without a difference; because guns can be lethal quickly and with relatively little effort, displaying or threatening with a gun can create a context known as coercive control, which facilitates chronic and escalating abuse. Implications for policy, practice, and research are discussed, all of which include expanding an implicit focus on homicide to include an intimate partner's nonfatal use of a gun. © The Author(s) 2016.

  1. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  2. Revisiting Pneumatic Nail Gun Trigger Recommendations.

    PubMed

    Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-03-01

    Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.

  3. Current transmission and nonlinear effects in un-gated thermionic cathode RF guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edelen, J. P.; Harris, J. R.

    Un-gated thermionic cathode RF guns are well known as a robust source of electrons for many accelerator applications. These sources are in principle scalable to high currents without degradation of the transverse emittance due to control grids but they are also known for being limited by back-bombardment. While back-bombardment presents a significant limitation, there is still a lack of general understanding on how emission over the whole RF period will affect the nature of the beams produced from these guns. In order to improve our understanding of how these guns can be used in general we develop analytical models thatmore » predict the transmission efficiency as a function of the design parameters, study how bunch compression and emission enhancement caused by Schottky barrier lowering affect the output current profile in the gun, and study the onset of space-charge limited effects and the resultant virtual cathode formation leading to a modulation in the output current distribution.« less

  4. Children, Youth, and Gun Violence.

    ERIC Educational Resources Information Center

    Behrman, Richard E., Ed.

    2002-01-01

    This collection of articles summarizes knowledge and research about how gun violence affects children and youth and discusses which policies hold promise for reducing youth gun violence. The papers are: (1) "Statement of Purpose" (Richard E. Behrman); "Children, Youth, and Gun Violence: Analysis and Recommendations" (Kathleen…

  5. X-Band RF Gun Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlieks, Arnold; Dolgashev, Valery; Tantawi, Sami

    In support of the MEGa-ray program at LLNL and the High Gradient research program at SLAC, a new X-band multi-cell RF gun is being developed. This gun, similar to earlier guns developed at SLAC for Compton X-ray source program, will be a standing wave structure made of 5.5 cells operating in the pi mode with copper cathode. This gun was designed following criteria used to build SLAC X-band high gradient accelerating structures. It is anticipated that this gun will operate with surface electric fields on the cathode of 200 MeV/m with low breakdown rate. RF will be coupled into themore » structure through a final cell with symmetric duel feeds and with a shape optimized to minimize quadrupole field components. In addition, geometry changes to the original gun, operated with Compton X-ray source, will include a wider RF mode separation, reduced surface electric and magnetic fields.« less

  6. Waves generated in the vicinity of an argon plasma gun in the ionosphere

    NASA Technical Reports Server (NTRS)

    Cahill, L. J., Jr.; Arnoldy, R. L.; Lysak, R. L.; Peria, W.; Lynch, K. A.

    1993-01-01

    Wave and particle observations were made in the close vicinity of an argon plasma gun carned to over 600 km altitude on a sounding rocket. The gun was carned on a subpayload, separated from the main payload early in the flight. Twelve-second argon ion ejections were energized alternately with a peak energy of 100 or 200 eV. They produced waves, with multiple harmonics, in the range of ion cyclotron waves, 10 to 1000 Hz at rocket altitudes. Many of these waves could not be identified as corresponding to the cyclotron frequencies of any of the ions, argon or ambient, known to be present. In addition, the wave frequencies were observed to rise and fall and to change abruptly during a 12-s gun operation. The wave amplitudes, near a few hundred Hertz, were of the order of O. 1 V/m. Some of the waves may be ion-ion hybrid waves. Changes in ion populations were observed at the main payload and at the subpayload during gun operations. A gun-related, field-aligned, electron population also appeared.

  7. Waves generated in the vicinity of an argon plasma gun in the ionosphere

    NASA Astrophysics Data System (ADS)

    Cahill, L. J., Jr.; Arnoldy, R. L.; Lysak, R. L.; Peria, W.; Lynch, K. A.

    1993-06-01

    Wave and particle observations were made in the close vicinity of an argon plasma gun carned to over 600 km altitude on a sounding rocket. The gun was carned on a subpayload, separated from the main payload early in the flight. Twelve-second argon ion ejections were energized alternately with a peak energy of 100 or 200 eV. They produced waves, with multiple harmonics, in the range of ion cyclotron waves, 10 to 1000 Hz at rocket altitudes. Many of these waves could not be identified as corresponding to the cyclotron frequencies of any of the ions, argon or ambient, known to be present. In addition, the wave frequencies were observed to rise and fall and to change abruptly during a 12-s gun operation. The wave amplitudes, near a few hundred Hertz, were of the order of O. 1 V/m. Some of the waves may be ion-ion hybrid waves. Changes in ion populations were observed at the main payload and at the subpayload during gun operations. A gun-related, field-aligned, electron population also appeared.

  8. Photocathode Optimization for a Dynamic Transmission Electron Microscope: Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ellis, P; Flom, Z; Heinselman, K

    2011-08-04

    The Dynamic Transmission Electron Microscope (DTEM) team at Harvey Mudd College has been sponsored by LLNL to design and build a test setup for optimizing the performance of the DTEM's electron source. Unlike a traditional TEM, the DTEM achieves much faster exposure times by using photoemission from a photocathode to produce electrons for imaging. The DTEM team's work is motivated by the need to improve the coherence and current density of the electron cloud produced by the electron gun in order to increase the image resolution and contrast achievable by DTEM. The photoemission test setup is nearly complete and themore » team will soon complete baseline tests of electron gun performance. The photoemission laser and high voltage power supply have been repaired; the optics path for relaying the laser to the photocathode has been finalized, assembled, and aligned; the internal setup of the vacuum chamber has been finalized and mostly implemented; and system control, synchronization, and data acquisition has been implemented in LabVIEW. Immediate future work includes determining a consistent alignment procedure to place the laser waist on the photocathode, and taking baseline performance measurements of the tantalum photocathode. Future research will examine the performance of the electron gun as a function of the photoemission laser profile, the photocathode material, and the geometry and voltages of the accelerating and focusing components in the electron gun. This report presents the team's progress and outlines the work that remains.« less

  9. Preventing gun injuries in children.

    PubMed

    Crossen, Eric J; Lewis, Brenna; Hoffman, Benjamin D

    2015-02-01

    Firearms are involved in the injury and death of a large number of children each year from both intentional and unintentional causes. Gun ownership in homes with children is common, and pediatricians should incorporate evidence-based means to discuss firearms and protect children from gun-related injuries and violence. Safe storage of guns, including unloaded guns locked and stored separately from ammunition, can decrease risks to children, and effective tools are available that pediatricians can use in clinical settings to help decrease children's access to firearms. Furthermore, several community-based interventions led by pediatricians have effectively reduced firearm-related injury risks to children. Educational programs that focus on children's behavior around guns have not proven effective. © American Academy of Pediatrics, 2015. All rights reserved.

  10. Gun violence trends in movies.

    PubMed

    Bushman, Brad J; Jamieson, Patrick E; Weitz, Ilana; Romer, Daniel

    2013-12-01

    Many scientific studies have shown that the mere presence of guns can increase aggression, an effect dubbed the "weapons effect." The current research examines a potential source of the weapons effect: guns depicted in top-selling films. Trained coders identified the presence of violence in each 5-minute film segment for one-half of the top 30 films since 1950 and the presence of guns in violent segments since 1985, the first full year the PG-13 rating (age 13+) was used. PG-13-rated films are among the top-selling films and are especially attractive to youth. Results found that violence in films has more than doubled since 1950, and gun violence in PG-13-rated films has more than tripled since 1985. When the PG-13 rating was introduced, these films contained about as much gun violence as G (general audiences) and PG (parental guidance suggested for young children) films. Since 2009, PG-13-rated films have contained as much or more violence as R-rated films (age 17+) films. Even if youth do not use guns, these findings suggest that they are exposed to increasing gun violence in top-selling films. By including guns in violent scenes, film producers may be strengthening the weapons effect and providing youth with scripts for using guns. These findings are concerning because many scientific studies have shown that violent films can increase aggression. Violent films are also now easily accessible to youth (e.g., on the Internet and cable). This research suggests that the presence of weapons in films might amplify the effects of violent films on aggression.

  11. Homemade battery-operated multi-barreled muzzle-loading gun.

    PubMed

    Ramiah, R; Thirunavukkarasu, G

    2003-11-01

    In a recent shootout by a terrorist group against a law enforcement agency, some unusual firearms were seized. On examination, these firearms were found to be homemade, battery-operated, multi-barreled muzzle-loading guns, analogous to a repeater. Reference to battery-operated firearms is rather scanty in the literature. Hence, the unique design features, electrical circuit, and the operation system of these unusual guns are described.

  12. Guns at College.

    ERIC Educational Resources Information Center

    Miller, Matthew; Hemenway, David; Wechsler, Henry

    1999-01-01

    Surveyed undergraduate students nationwide concerning firearm possession. About 3.5% possessed working firearms. Students with guns were more likely to be male, White, or Native American; binge drink; live off-campus; and live with a spouse or significant other. Students with guns were more likely to engage in activities that put themselves and…

  13. A gasdynamic gun driven by gaseous detonation

    NASA Astrophysics Data System (ADS)

    Li, Jinping; Chen, Hong; Zhang, Shizhong; Zhang, Xiaoyuan; Yu, Hongru

    2016-01-01

    A gasdynamic gun driven by gaseous detonation was developed to address the disadvantages of the insufficient driving capability of high-pressure gas and the constraints of gunpowder. The performance of this gasdynamic gun was investigated through experiments and numerical simulations. Much more powerful launching capability was achieved by this gun relative to a conventional high-pressure gas gun, owing to the use of the chemical energy of the driver gas. To achieve the same launching condition, the initial pressure required for this gun was an order of magnitude lower than that for a gun driven by high-pressure H2. Because of the presence of the detonation, however, a more complex internal ballistic process of this gun was observed. Acceleration of projectiles for this gun was accompanied by a series of impulse loads, in contrast with the smooth acceleration for a conventional one, which indicates that this gun should be used conditionally. The practical feasibility of this gun was verified by experiments. The experiments demonstrated the convenience of taking advantage of the techniques developed for detonation-driven shock tubes and tunnels.

  14. Teen Suicide and Guns

    MedlinePlus

    ... Text Size Email Print Share Teen Suicide and Guns Page Content Article Body Protect Your Teenager Many ... American teenagers commit suicide every day. Does a gun in the home increase the chance of suicide? ...

  15. Vacuum vapor deposition gun assembly

    DOEpatents

    Zeren, Joseph D.

    1985-01-01

    A vapor deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, a hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  16. Methods for coating conduit interior surfaces utilizing a thermal spray gun with extension arm

    DOEpatents

    Moore, Karen A.; Zatorski, Raymond A.

    2007-10-02

    Systems and methods for applying a coating to an interior surface of a conduit. In one embodiment, a spray gun configured to apply a coating is attached to an extension arm which may be inserted into the bore of a pipe. The spray gun may be a thermal spray gun adapted to apply a powder coating. An evacuation system may be used to provide a volume area of reduced air pressure for drawing overspray out of the pipe interior during coating. The extension arm as well as the spray gun may be cooled to maintain a consistent temperature in the system, allowing for more consistent coating.

  17. 78 FR 66840 - Revocation of Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ... Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns Not Intended for Use... regulations pertaining to caps intended for use with toy guns refer to obsolete equipment, but the ASTM F963... revokes the existing regulations pertaining to caps intended for use with toy guns and toy guns not...

  18. Compact pulse transformer for 85 kV, 3.5 μs electron gun anode of compact X-ray cargo scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patel, R.; Sharma, D.K.; Dixit, K.

    Design of compact and reliable 85kV HV pulse transformer for electron gun anode pulsing is a major concern, when size and space are constraints. This paper describes design procedures and optimization of various parameters like HV insulation, step up ratio, rise time and flat top of Pulse transformer, operating with input from a 10 stage PFN of 50 ohm impedance and charged at 14kV. The transformer should deliver rated output voltage of negative polarity 85kV, 3 to 4μs pulse width, less than 2μs rise time and flat top within 10% across an electron gun load, equivalent to a parallel combinationmore » of 10kΩ and 200pF load at a PRF of 250 Hz. Since the Cargo Scanner has to operate on movable carrier, this transformer is designed to operate even in the inclined positions. This transformer has given voltage step up, rise time and flat top of 13.75, 1.5 μs and 4.5% respectively for a 10kΩ and 200pF load at 250Hz PRF and also demonstrated operation in 90{sup °} tilted transformer positions. An effort has been put to achieve maintenance free Pulse transformer by providing effective sealing in the transformer tank to stop breathing action. Also, special flexing walls of transformer tank accommodate for small changes in volume of oil due to temperature variations. (author)« less

  19. Simulation and Characterization of a Miniaturized Scanning Electron Microscope

    NASA Technical Reports Server (NTRS)

    Gaskin, Jessica A.; Jerman, Gregory A.; Medley, Stephanie; Gregory, Don; Abbott, Terry O.; Sampson, Allen R.

    2011-01-01

    A miniaturized Scanning Electron Microscope (mSEM) for in-situ lunar investigations is being developed at NASA Marshall Space Flight Center with colleagues from the University of Alabama in Huntsville (UAH), Advanced Research Systems (ARS), the University of Tennessee in Knoxville (UTK) and Case Western Reserve University (CWRU). This effort focuses on the characterization of individual components of the mSEM and simulation of the complete system. SEMs can provide information on the size, shape, morphology and chemical composition of lunar regolith. Understanding these basic properties will allow us to better estimate the challenges associated with In-Situ Resource Utilization and to improve our basic science knowledge of the lunar surface (either precluding the need for sample return or allowing differentiation of unique samples to be returned to Earth.) The main components of the mSEM prototype includes: a cold field emission electron gun (CFEG), focusing lens, deflection/scanning system and backscatter electron detector. Of these, the electron gun development is of particular importance as it dictates much of the design of the remaining components. A CFEG was chosen for use with the lunar mSEM as its emission does not depend on heating of the tungsten emitter (lower power), it offers a long operation lifetime, is orders of magnitude brighter than tungsten hairpin guns, has a small source size and exhibits low beam energy spread.

  20. Compression-Ignition Sensitivity Studies of Liquid Propellants for Guns

    DTIC Science & Technology

    1979-07-01

    a -- h f m1 Report No. PCRL-F’.-75-004 July 1979 COMPRESSION-I=NITION SDNSITrI"Y STUDIES j? LIQUID PROPELLAhTS rOR GUNS Contract No. DAXK10-78-C-0315...Rmpression- qnition nsitivit 24AU7ud1ies,ś of Liquid Pr ielants or Guns # It) M~oehe BenReuven E6ad Martin ýumme rfielId - AAK10-78-C-0315/J 9...levels and pressurization rates comparable to .’iose of liquid propellant gun (LPG) systems, particularly during the start-up phase o-f the ballistic cycle

  1. Hot hollow cathode gun assembly

    DOEpatents

    Zeren, J.D.

    1983-11-22

    A hot hollow cathode deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, the hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  2. Measurement of groove features and dimensions of the vertical test cathode and the choke joint of the superconducting electron gun cavity of the Energy Recovery LINAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hammons, L.; Ke, M.

    2011-10-13

    with the vertical test cathode, the geometry of these grooves was altered, presenting the possibility that multipacting may, in fact, be occurring in this area and contributing to the low gradients that have been observed in the fine-grain cavity. Therefore, the Survey and Alignment group in C-AD engaged in measurements of the cavity joint, shown in Figure 2 and the cathode weldment, shown in Figure 3 for the purpose of characterizing the grooves in both the cavity and the vertical test cathode and comparing the dimensions of the cathode with those of the prints supplied by Advanced Energy Systems (AES), the original designer and manufacturer of both the test cathode and the electron gun cavity, in preparation to have a new one manufactured. The goal was to ensure that the articles as built matched the design prints in preparation for manufacturing a new vertical test cathode. This report describes the data collected by the Survey group in these efforts. The endeavor was challenging for the group given the millimeter-scale dimensions of the grooves and the requirement for high precision.« less

  3. Automatic targeting of plasma spray gun

    DOEpatents

    Abbatiello, Leonard A.; Neal, Richard E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is provided. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun.

  4. The synthesis method for design of electron flow sources

    NASA Astrophysics Data System (ADS)

    Alexahin, Yu I.; Molodozhenzev, A. Yu

    1997-01-01

    The synthesis method to design a relativistic magnetically - focused beam source is described in this paper. It allows to find a shape of electrodes necessary to produce laminar space charge flows. Electron guns with shielded cathodes designed with this method were analyzed using the EGUN code. The obtained results have shown the coincidence of the synthesis and analysis calculations [1]. This method of electron gun calculation may be applied for immersed electron flows - of interest for the EBIS electron gun design.

  5. 46th Annual Gun and Missile Systems Conference and Exhibition. Volume 2. Wednesday

    DTIC Science & Technology

    2011-09-01

    military/systems/munitions/images/ Page 7 Designing for Operational Challenges  Gun hardening – Multiple charges • Angular acceleration variation ...The industrial base overestimated readiness at SDD start – Analysis/models were naive • Impulsive loads — pressure variation — SOM under impulse...Manufacture and Producibility Branch, US Army Armament Research, Development and Engineering Center • Alan Sweet and William Goldberg , Packaging Division

  6. Are "goods for guns" good for the community? An update of a community gun buyback program.

    PubMed

    Green, Jonathan; Damle, Rachelle N; Kasper, Rebecca E; Violano, Pina; Manno, Mariann; Nazarey, Pradeep P; Aidlen, Jeremy T; Hirsh, Michael P

    2017-08-01

    Gun violence remains a leading cause of death in the United States. Community gun buyback programs provide an opportunity to dispose of extraneous firearms. The purpose of this study was to understand the demographics, motivation, child access to firearms, and household mental illness of buyback participants in hopes of improving the program's effectiveness. A 2015 Injury Free Coalition for Kids gun buyback program which collaborated with local police departments was studied. We administered a 23-item questionnaire survey to gun buyback participants assessing demographic characteristics, motivation for relinquishing firearms, child firearm accessibility, and mental illness/domestic violence history. A total of 186 individuals from Central/Western Massachusetts turned in 339 weapons. Participants received between US $25 and US $75 in gift cards dependent on what type of gun was turned in, with an average cost of $41/gun. A total of 109 (59%) participants completed the survey. Respondents were mostly white (99%), men (90%) and first-time participants in the program (85.2%). Among survey respondents, 54% turned in firearms "for safety reasons." Respondents reported no longer needing/wanting their weapons (47%) and approximately one in eight participants were concerned the firearm(s) were accessible to children. Most respondents (87%) felt the program encouraged neighborhood awareness of firearm safety. Three of every five participants reported that guns still remained in their homes; additionally, 21% where children could potentially access them and 14% with a history of mental illness/suicide/domestic violence in the home. Gun buybacks can provide a low-cost means of removing unwanted firearms from the community. Most participants felt their homes were safer after turning in the firearm(s). In homes still possessing guns, emphasis on secure gun storage should continue, increasing the safety of children and families. The results of this survey also provided new

  7. Characterizing and Optimizing Photocathode Laser Distributions for Ultra-low Emittance Electron Beam Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, F.; Bohler, D.; Ding, Y.

    2015-12-07

    Photocathode RF gun has been widely used for generation of high-brightness electron beams for many different applications. We found that the drive laser distributions in such RF guns play important roles in minimizing the electron beam emittance. Characterizing the laser distributions with measurable parameters and optimizing beam emittance versus the laser distribution parameters in both spatial and temporal directions are highly desired for high-brightness electron beam operation. In this paper, we report systematic measurements and simulations of emittance dependence on the measurable parameters represented for spatial and temporal laser distributions at the photocathode RF gun systems of Linac Coherent Lightmore » Source. The tolerable parameter ranges for photocathode drive laser distributions in both directions are presented for ultra-low emittance beam operations.« less

  8. Glue Guns: Aiming for Safety

    ERIC Educational Resources Information Center

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  9. Electron Source based on Superconducting RF

    NASA Astrophysics Data System (ADS)

    Xin, Tianmu

    High-bunch-charge photoemission electron-sources operating in a Continuous Wave (CW) mode can provide high peak current as well as the high average current which are required for many advanced applications of accelerators facilities, for example, electron coolers for hadron beams, electron-ion colliders, and Free-Electron Lasers (FELs). Superconducting Radio Frequency (SRF) has many advantages over other electron-injector technologies, especially when it is working in CW mode as it offers higher repetition rate. An 112 MHz SRF electron photo-injector (gun) was developed at Brookhaven National Laboratory (BNL) to produce high-brightness and high-bunch-charge bunches for electron cooling experiments. The gun utilizes a Quarter-Wave Resonator (QWR) geometry for a compact structure and improved electron beam dynamics. The detailed RF design of the cavity, fundamental coupler and cathode stalk are presented in this work. A GPU accelerated code was written to improve the speed of simulation of multipacting, an important hurdle the SRF structure has to overcome in various locations. The injector utilizes high Quantum Efficiency (QE) multi-alkali photocathodes (K2CsSb) for generating electrons. The cathode fabrication system and procedure are also included in the thesis. Beam dynamic simulation of the injector was done with the code ASTRA. To find the optimized parameters of the cavities and beam optics, the author wrote a genetic algorithm Python script to search for the best solution in this high-dimensional parameter space. The gun was successfully commissioned and produced world record bunch charge and average current in an SRF photo-injector.

  10. "Is there a gun in the home?" Assessing the risks of gun ownership in older adults.

    PubMed

    Pinholt, Ellen M; Mitchell, Joshua D; Butler, Jane H; Kumar, Harjinder

    2014-06-01

    An important ethical and safety concern that geriatricians, primary care providers, and home health professionals need to address is gun ownership by elderly adults. Those aged 65 and older now have the highest rate of gun ownership in America, and they also have a high prevalence of depression and suicide. Dementia can add additional layers of risk. Even older gun owners who are otherwise intellectually intact may benefit from information about gun safety with the increasing numbers of children being cared for by grandparents. Health professionals should ask patients, "Is there a gun in the home?" in the clinic and during home visits. Healthcare professionals must have knowledge and skills to address safe gun ownership in elderly adults. The 5 L's (Locked, Loaded, Little children, feeling Low, Learned owner) will assist professionals in addressing all aspects of safe ownership. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  11. Electron linear accelerator system for natural rubber vulcanization

    NASA Astrophysics Data System (ADS)

    Rimjaem, S.; Kongmon, E.; Rhodes, M. W.; Saisut, J.; Thongbai, C.

    2017-09-01

    Development of an electron accelerator system, beam diagnostic instruments, an irradiation apparatus and electron beam processing methodology for natural rubber vulcanization is underway at the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The project is carried out with the aims to improve the qualities of natural rubber products. The system consists of a DC thermionic electron gun, 5-cell standing-wave radio-frequency (RF) linear accelerator (linac) with side-coupling cavities and an electron beam irradiation apparatus. This system is used to produce electron beams with an adjustable energy between 0.5 and 4 MeV and a pulse current of 10-100 mA at a pulse repetition rate of 20-400 Hz. An average absorbed dose between 160 and 640 Gy is expected to be archived for 4 MeV electron beam when the accelerator is operated at 400 Hz. The research activities focus firstly on assembling of the accelerator system, study on accelerator properties and electron beam dynamic simulations. The resonant frequency of the RF linac in π/2 operating mode is 2996.82 MHz for the operating temperature of 35 °C. The beam dynamic simulations were conducted by using the code ASTRA. Simulation results suggest that electron beams with an average energy of 4.002 MeV can be obtained when the linac accelerating gradient is 41.7 MV/m. The rms transverse beam size and normalized rms transverse emittance at the linac exit are 0.91 mm and 10.48 π mm·mrad, respectively. This information can then be used as the input data for Monte Carlo simulations to estimate the electron beam penetration depth and dose distribution in the natural rubber latex. The study results from this research will be used to define optimal conditions for natural rubber vulcanization with different electron beam energies and doses. This is very useful for development of future practical industrial accelerator units.

  12. Gun muzzle blast and flash

    NASA Astrophysics Data System (ADS)

    Klingenberg, Guenter; Heimerl, Joseph M.

    A repository of fundamental experimental and analytical data concerning the complex phenomena associated with gun-muzzle blast and flash effects is presented, proceeding from gun muzzle signatures to modern gun-propulsion concepts, interior and transitional ballistics, and characterizations of blast-wave research and muzzle flash. Data are presented in support of a novel hypothesis which explains the ignition of secondary flash and elucidates the means for its suppression. Both chemical and mechanical (often competing) methods of flash suppression are treated. The historical work of Kesslau and Ladenburg is noted, together with French, British, Japanese and American research efforts and current techniques of experimental characterization for gun muzzle phenomena.

  13. Implementation of glider guns in the light-sensitive Belousov-Zhabotinsky medium.

    PubMed

    de Lacy Costello, Ben; Toth, Rita; Stone, Christopher; Adamatzky, Andrew; Bull, Larry

    2009-02-01

    In cellular automata models a glider gun is an oscillating pattern of nonquiescent states that periodically emits traveling localizations (gliders). The glider streams can be combined to construct functionally complete systems of logical gates and thus realize universal computation. The glider gun is the only means of ensuring the negation operation without additional external input and therefore is an essential component of a collision-based computing circuit. We demonstrate the existence of glider-gun-like structures in both experimental and numerical studies of an excitable chemical system-the light-sensitive Belousov-Zhabotinsky reaction. These discoveries could provide the basis for future designs of collision-based reaction-diffusion computers.

  14. Los Alamos Guns Take Aim at Material's Mysteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byers, Mark; Moore, David; Dimarino, Steve

    Los Alamos National Laboratory scientists and technicians conduct thousands of experiments a year, delving into the fundamental nature of everything from supernovas to subatomic particles. One set of instruments used to better understand the fundamental nature of various materials are 10 scientific gun systems that fire various projectiles at high-tech targets to create enormous velocities, pressures, and temperatures - and using laser, x-ray, and other diagnostics - explore the very nature of metals and other materials. The hundreds of gun-based experiments conducted every year at the Laboratory require a highly-skilled staff of scientists and technicians, and has given rise tomore » a special organization called the "gun working group" to foster open communications, cooperation, problem-solving, and a healthy safety culture.« less

  15. Los Alamos Guns Take Aim at Material's Mysteries

    ScienceCinema

    Byers, Mark; Moore, David; Dimarino, Steve

    2018-05-30

    Los Alamos National Laboratory scientists and technicians conduct thousands of experiments a year, delving into the fundamental nature of everything from supernovas to subatomic particles. One set of instruments used to better understand the fundamental nature of various materials are 10 scientific gun systems that fire various projectiles at high-tech targets to create enormous velocities, pressures, and temperatures - and using laser, x-ray, and other diagnostics - explore the very nature of metals and other materials. The hundreds of gun-based experiments conducted every year at the Laboratory require a highly-skilled staff of scientists and technicians, and has given rise to a special organization called the "gun working group" to foster open communications, cooperation, problem-solving, and a healthy safety culture.

  16. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, J. R.; Carmichael, J. R.; Gebhart, T. E.

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze themore » dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet

  17. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Combs, S. K.; Reed, J. R.; Lyttle, M. S.

    2016-01-01

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze themore » dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet

  18. Gun Violence Restraining Orders: Alternative or Adjunct to Mental Health-Based Restrictions on Firearms?

    PubMed

    Frattaroli, Shannon; McGinty, Emma E; Barnhorst, Amy; Greenberg, Sheldon

    2015-06-01

    The gun violence restraining order (GVRO) is a new tool for preventing gun violence. Unlike traditional approaches to prohibiting gun purchase and possession, which rely on a high threshold (adjudication by criminal justice or mental health systems) before intervening, the GVRO allows family members and intimate partners who observe a relative's dangerous behavior and believe it may be a precursor to violence to request a GVRO through the civil justice system. Once issued by the court, a GVRO authorizes law enforcement to remove any guns in the respondent's possession and prohibits the respondent from purchasing new guns. In September 2014, California's governor signed AB1014 into law, making California the first U.S. state to enact a GVRO law. This article describes the GVRO and the rationale behind the concept, considers case examples to assess the potential impact of the GVRO as a strategy for preventing gun violence, and reviews the content of the California law. Copyright © 2015 John Wiley & Sons, Ltd.

  19. High-quality imaging in environmental scanning electron microscopy--optimizing the pressure limiting system and the secondary electron detection of a commercially available ESEM.

    PubMed

    Fitzek, H; Schroettner, H; Wagner, J; Hofer, F; Rattenberger, J

    2016-04-01

    In environmental scanning electron microscopy applications in the kPa regime are of increasing interest for the investigation of wet and biological samples, because neither sample preparation nor extensive cooling are necessary. Unfortunately, the applications are limited by poor image quality. In this work the image quality at high pressures of a FEI Quanta 600 (field emission gun) and a FEI Quanta 200 (thermionic gun) is greatly improved by optimizing the pressure limiting system and the secondary electron (SE) detection system. The scattering of the primary electron beam strongly increases with pressure and thus the image quality vanishes. The key to high-image quality at high pressures is to reduce scattering as far as possible while maintaining ideal operation conditions for the SE-detector. The amount of scattering is reduced by reducing both the additional stagnation gas thickness (aSGT) and the environmental distance (ED). A new aperture holder is presented that significantly reduces the aSGT while maintaining the same field-of-view (FOV) as the original design. With this aperture holder it is also possible to make the aSGT even smaller at the expense of a smaller FOV. A new blade-shaped SE-detector is presented yielding better image quality than usual flat SE-detectors. The electrode of the new SE detector is positioned on the sample table, which allows the SE-detector to operate at ideal conditions regardless of pressure and ED. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  20. Gas gun dynamics

    NASA Astrophysics Data System (ADS)

    Denny, Mark

    2013-09-01

    The mechanics and thermodynamics of one- and two-stage gas guns are developed. Very high projectile muzzle speed can be obtained by the two-stage version. The physics of simple gas guns, such as air rifles, is accessible to undergraduates and the same level of presentation is used here to understand more complex designs. Numerical solutions to the equations of motion are shown, along with insightful analytic approximations.

  1. Laser High-Speed Photography System Used To Take Pictures Of The Attitudes Of Flying Projectile At The Muzzle Of Heavy Calibre Gun

    NASA Astrophysics Data System (ADS)

    Yuren, Wang; Fang, Shao; Weiping, Sun; Xioujuan, Li; Suning, Tian; Hongyan, Li

    1989-06-01

    When a heavy-calibre gun is fired and a projectite is flying near the gun muzzle, velocity of the projectile is very high and firing process is accompanying with strong muzzle flash. So taking the picture of the attitudes of flying projectile at the gun muzzle is very difficult. "YDS speed Photography System" developed by our group can take the framing pictures of the attitudes of the projectile and prevent them from flash confusing at the muzzle. Since framing depends on sequential pulse of the laser and the width of the putse is very narrow, therefore the exposure time is very short and photos of high-velocity flying body taken are very clear. This paper Introduces configuration and operation principle of "YDS laser High-speed Photography System" and the fuctions of the devices in this system In addition, some experimental results are briefly introduced.

  2. Cost Estimate for Gun Liner Emplacement

    DTIC Science & Technology

    2011-08-01

    material. The M2 machine gun has a Stellite 21 liner that covers only about one-half of the barrel length. It has been successful in reducing the...Michael R. M2 Machine Gun Barrel Wear with SLAP Ammunition. To be published in Journal of Materials and Manufacturing Processes. 8. Miller, Mark D...case in point is the use of a Stellite 21 liner in the M2 0.50-cal machine gun . However, liners have generally been difficult to place into gun tubes

  3. Alignment Fixtures For Vacuum-Plasma-Spray Gun

    NASA Technical Reports Server (NTRS)

    Woodford, William H.; Mckechnie, Timothy N.; Power, Christopher A.; Daniel, Ronald L., Jr.

    1993-01-01

    Fixtures for alignment of vacuum-plasma-spray guns built. Each fixture designed to fit specific gun and holds small, battery-powered laser on centerline of gun. Laser beam projects small red dot where centerline intersects surface of workpiece to be sprayed. After laser beam positioned on surface of workpiece, fixture removed from gun and spraying proceeds.

  4. Advances in light-gas gun technology

    NASA Technical Reports Server (NTRS)

    Cowan, P. L.; Murphy, J. R.

    1968-01-01

    Constant-area accelerator used with light-gas guns increases the velocity of accelerating projectiles. A disposable accelerator on the muzzle of the gun uses the energy and momentum of a primary projectile, launched by the gun, to achieve high velocities of a light secondary projectile accelerated from rest in the accelerator.

  5. The electron-optical system of the LIU-2 induction accelerator

    NASA Astrophysics Data System (ADS)

    Kuznetsov, G. I.; Batazova, M. A.

    2014-09-01

    The electron-optical system (EOS) of an induction accelerator for generation of an electron beam with an energy of 2 MeV, a current of 2 kA, an impulse duration of 2 × 10-7 s, and a geometric output emittance not exceeding the thermal value of it is described. The EOS consists of two parts. The first part is a diode gun with a perveance of 2 × 10-6 A/B3/2 and a cathode-anode voltage of 1 MeV. The second part is an accelerating tube with uniform distribution of the same accelerating voltage. A beam is transported at a distance of about 4 m from the cathode and focused on a spot with a diameter of about 1 mm. The compliance tests results of the linear-induction accelerator precisely conform to the calculated design parameters.

  6. S3 targets monitoring with an electron gun

    NASA Astrophysics Data System (ADS)

    Kallunkathariyil, J.; Stodel, Ch.; Marry, C.; Frémont, G.; Bastin, B.; Piot, J.; Clément, E.; Le Moal, S.; Morel, V.; Thomas, J.-C.; Kamalou, O.; Spitaëls, C.; Savajols, H.; Vostinar, M.; Pellemoine, F.; Mittig, W.

    2018-05-01

    The monitoring of targets under irradiation was investigated using a 20 keV electron beam. An integrated and automated electron beam deflection was developed allowing a monitoring over the whole surface of target materials. Thus, local defects could be identified on-line during an experiment performed at GANIL involving different materials irradiated with a focused krypton beam at 10.5 MeV/u. Performances of this target monitoring system are presented in this paper.

  7. Association Between Substance Use and Gun-Related Behaviors

    PubMed Central

    Chen, Danhong; Wu, Li-Tzy

    2016-01-01

    Gun-related violence is a public health concern. This study synthesizes findings on associations between substance use and gun-related behaviors. Searches through PubMed, Embase, and PsycINFO located 66 studies published in English between 1992 and 2014. Most studies found a significant bivariate association between substance use and increased odds of gun-related behaviors. However, their association after adjustment was mixed, which could be attributed to a number of factors such as variations in definitions of substance use and gun activity, study design, sample demographics, and the specific covariates considered. Fewer studies identified a significant association between substance use and gun access/possession than other gun activities. The significant association between nonsubstance covariates (e.g., demographic covariates and other behavioral risk factors) and gun-related behaviors might have moderated the association between substance use and gun activities. Particularly, the strength of association between substance use and gun activities tended to reduce appreciably or to become nonsignificant after adjustment for mental disorders. Some studies indicated a positive association between the frequency of substance use and the odds of engaging in gun-related behaviors. Overall, the results suggest a need to consider substance use in research and prevention programs for gun-related violence. PMID:26769722

  8. Nail-Gun Injuries to the Hand

    PubMed Central

    Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.

    2008-01-01

    Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574

  9. Automated pinhole-aperture diagnostic for the current profiling of TWT electron beams

    NASA Astrophysics Data System (ADS)

    Wei, Yu-Xiang; Huang, Ming-Guang; Liu, Shu-Qing; Liu, Jin-Yue; Hao, Bao-Liang; Du, Chao-Hai; Liu, Pu-Kun

    2013-02-01

    The measurement system reported here is intended for use in determining the current density distribution of electron beams from Pierce guns for use in TWTs. The system was designed to automatically scan the cross section of the electron beam and collect the high-resolution data with a Faraday cup probe mounted on a multistage manipulator using the LabVIEW program. A 0.06 mm thick molybdenum plate with a pinhole and a Faraday cup mounted as a probe assembly was employed to sample the electron beam current with 0.5 µm space resolution. The thermal analysis of the probe with pulse beam heating was discussed. A 0.45 µP electron gun with the expected minimum beam radius 0.42 mm was measured and the three-dimensional current density distribution, beam envelope and phase space were presented.

  10. The Status of Normal Conducting RF (NCRF) Guns, a Summary of the ERL2005 Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, D.H.; /SLAC; Lewellen, J.W.

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20 to 23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrated upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433MHz was demonstrated at 25%DFmore » in 1992, while the CW and much improved version is currently being constructed at 700MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.« less

  11. The status of normal conducting RF (NCRF) guns; a summary of the ERL2005 Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.H. Dowell; J.W. Lewellen; D. Nguyen

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20 to 23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrated upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433MHz was demonstrated at 25%DFmore » in 1992, while the CW and much improved version is currently being constructed at 700MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.« less

  12. The status of normal conducting RF (NCRF) guns, a summary of the ERL2005 workshop

    NASA Astrophysics Data System (ADS)

    Dowell, David H.; Lewellen, John W.; Nguyen, Dinh; Rimmer, Robert

    2006-02-01

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20-23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrating upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433 MHz was demonstrated at 25%DF in 1992, while the CW and much improved version is currently being constructed at 700 MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE-free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.

  13. Remotely controlled spray gun

    NASA Technical Reports Server (NTRS)

    Cunningham, William C. (Inventor)

    1987-01-01

    A remotely controlled spray gun is described in which a nozzle and orifice plate are held in precise axial alignment by an alignment member, which in turn is held in alignment with the general outlet of the spray gun by insert. By this arrangement, the precise repeatability of spray patterns is insured.

  14. Interpreting the empirical evidence on illegal gun market dynamics.

    PubMed

    Braga, Anthony A; Wintemute, Garen J; Pierce, Glenn L; Cook, Philip J; Ridgeway, Greg

    2012-10-01

    Thousands of Americans are killed by gunfire each year, and hundreds of thousands more are injured or threatened with guns in robberies and assaults. The burden of gun violence in urban areas is particularly high. Critics suggest that the results of firearm trace data and gun trafficking investigation studies cannot be used to understand the illegal supply of guns to criminals and, therefore, that regulatory and enforcement efforts designed to disrupt illegal firearms markets are futile in addressing criminal access to firearms. In this paper, we present new data to address three key arguments used by skeptics to undermine research on illegal gun market dynamics. We find that criminals rely upon a diverse set of illegal diversion pathways to acquire guns, gun traffickers usually divert small numbers of guns, newer guns are diverted through close-to-retail diversions from legal firearms commerce, and that a diverse set of gun trafficking indicators are needed to identify and shut down gun trafficking pathways.

  15. Construction and characterization of the fringe field monochromator for a field emission gun

    PubMed

    Mook; Kruit

    2000-04-01

    Although some microscopes have shown stabilities sufficient to attain below 0.1 eV spectral resolution in high-resolution electron energy loss spectroscopy, the intrinsic energy width of the high brightness source (0.3-0.6 eV) has been limiting the resolution. To lower the energy width of the source to 50 meV without unnecessary loss of brightness, a monochromator has been designed consisting of a short (4 mm) fringe field Wien filter and a 150 nm energy selection slit (nanoslit) both to be incorporated in the gun area of the microscope. A prototype has been built and tested in an ultra-high-vacuum setup (10(-9) mbar). The monochromator, operating on a Schottky field emission gun, showed stable and reproducible operation. The nanoslits did not contaminate and the structure remained stable. By measuring the current through the slit structure a direct image of the beam in the monochromator could be attained and the monochromator could be aligned without the use of a microscope. Good dispersed imaging conditions were found indicating an ultimate resolution of 55 meV. A Mark II fringe field monochromator (FFM) was designed and constructed compatible with the cold tungsten field emitter of the VG scanning transmission microscope. The monochromator was incorporated in the gun area of the microscope at IBM T.J. Watson research center, New York. The monochromator was aligned on 100 kV and the energy distribution measured using the monochromator displayed a below 50 meV filtering capability. The retarding Wien filter spectrometer was used to show a 61 meV EELS system resolution. The FFM is shown to be a monochromator which can be aligned without the use of the electron microscope. This makes it directly applicable for scanning transmission microscopy and low-voltage scanning electron microscopy, where it can lower the resolution loss which is caused by chromatic blur of the spot.

  16. Evaluation of Needle Gun and Abrasive Blasting Technologies in Bridge Paint Removal Practices.

    PubMed

    Randall, Paul M; Kranz, Paul B; Sonntag, Mary L; Stadelmaier, James E

    1998-03-01

    This paper reviews the results of a U.S. Environmental Protection Agency (EPA) study that assessed needle gun technology as an alternative to conventional abrasive blasting technology to remove lead-based paint from steel bridges in western New York State. The study analyzed the operational and logistical aspects as they relate to worker health and safety, environmental protection, hazardous waste generation, and costs as compared to those arising from conventional abrasive blasting. In this 1992 EPA study, the costs and the product quality aspects favored conventional abrasive blasting over the needle gun technology for removing lead paint. However, abrasive blasting exposed workers to airborne lead levels that exceeded Permissible Exposure Limits (PELs) as established by the Occupational Safety and Health Administration (OSHA), as well as emitting high levels of lead-contaminated dusts and debris into the environment. It was estimated that more than 500 lbs of lead-contaminated spent abrasives and paint waste were released into the environment during paint removal operations. The needle gun system reduced (up to 97.5%) the generation of hazardous waste and the airborne concentrations (up to 99%) of respirable dusts and lead-containing particulates generated during paint removal operations. However, labor costs for the needle gun were three times higher than those for abrasive blasting primarily because of slower production rates that necessitated more operating personnel. The higher labor costs of the needle gun are partially offset by the increased costs associated with the expendable abrasive blast media and hazardous waste disposal. In the EPA study, the productivity of the needle gun system was 12.2 ft 2 /hr vs. 147.5 ft 2 /hr for abrasive blasting. A post blast was needed for the needle gun system to meet surface preparation specifications. When factoring in the costs of full containment structures to meet OSHA's 1993 Lead Exposure in Construction regulation

  17. Community gun safety in Central Pennsylvania.

    PubMed

    Wargo, Christina; Erdman, Deborah A; Smith, Jill Gray; Widom, Kenneth; Reardon, Judith

    2013-01-01

    Firearm-related injuries are a public health issue in the United States. In rural Pennsylvania, it is a familiar way of life to have a gun or guns in the home. Safety behaviors along with gun storage in the home, specifically where there are young children (aged 6 years and younger), are a concern for this level I regional resource center in rural Pennsylvania. Head Start families were surveyed regarding gun safety habits before and after safety educational activities. A noteworthy number of families reported changing behaviors regarding better safety habits for storing and use of firearms in the home postsurvey.

  18. Correlates of Gun Involvement and Aggressiveness among Adolescents.

    ERIC Educational Resources Information Center

    Ding, Cody S.; Nelsen, Edward A.; Lassonde, Cynthia T.

    2002-01-01

    Investigated adolescents' aggressiveness in relation to their experiences, beliefs, and attitudes concerning gun use, also noting family composition, relationships with parents, and emotionality as correlates of gun involvement and aggression. Student surveys indicated links between gun ownership and recreational use, beliefs about gun use, and…

  19. Gun Violence, mental health, and Connecticut physicians.

    PubMed

    Dodds, Peter R; Anderson, Caitlyn O; Dodds, Jon H

    2014-01-01

    While there is a public perception that gun violence is associated with mental illness we present evidence that it is a complex public health problem which defies simple characterizations and solutions. Only a small percentage of individuals with mental illness are at risk for extreme violence and they account for only a small percentage of gun-related homicides. Individuals who are at risk for gun violence are difficult to identify and successfully treat. The incidence, and perhaps the demographics, of gun violence vary substantially from state to state. We make a case for Connecticut physicians to study gun violence at the state level. We recommend that Connecticut physicians promote and expand upon the American Academy of Pediatrics' recommendation for creating a "safe home environment. "We suggest that guns be secured in all homes in which there are children. In addition we suggest that guns be voluntarily removed from homes in which there are individuals with a history of violence, threats of violence, depression, drug and/or alcohol abuse, and individuals with major mental illnesses who are not cooperating with therapy.

  20. Is There a Gun in the House? Gun Safety in the Home.

    ERIC Educational Resources Information Center

    Keller, Rosanne

    Written in a conversational style with illustrations, this booklet from a series of home literacy readers is directed at the Alaskan environment where guns are a way of life, used for food and defense from animals. But more than 10% of the 1,300 U.S. deaths from gun accidents occur in Alaska, and more than 70%, at home. Nearly half the victims are…

  1. STREAK CAMERA MEASUREMENTS OF THE APS PC GUN DRIVE LASER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooling, J. C.; Lumpkin, A. H.

    We report recent pulse-duration measurements of the APS PC Gun drive laser at both second harmonic and fourth harmonic wavelengths. The drive laser is a Nd:Glass-based chirped pulsed amplifier (CPA) operating at an IR wavelength of 1053 nm, twice frequency-doubled to obtain UV output for the gun. A Hamamatsu C5680 streak camera and an M5675 synchroscan unit are used for these measurements; the synchroscan unit is tuned to 119 MHz, the 24th subharmonic of the linac s-band operating frequency. Calibration is accomplished both electronically and optically. Electronic calibration utilizes a programmable delay line in the 119 MHz rf path. Themore » optical delay uses an etalon with known spacing between reflecting surfaces and is coated for the visible, SH wavelength. IR pulse duration is monitored with an autocorrelator. Fitting the streak camera image projected profiles with Gaussians, UV rms pulse durations are found to vary from 2.1 ps to 3.5 ps as the IR varies from 2.2 ps to 5.2 ps.« less

  2. Association Between Substance Use and Gun-Related Behaviors.

    PubMed

    Chen, Danhong; Wu, Li-Tzy

    2016-01-01

    Gun-related violence is a public health concern. This study synthesizes findings on associations between substance use and gun-related behaviors. Searches through PubMed, Embase, and PsycINFO located 66 studies published in English between 1992 and 2014. Most studies found a significant bivariate association between substance use and increased odds of gun-related behaviors. However, their association after adjustment was mixed, which could be attributed to a number of factors such as variations in definitions of substance use and gun activity, study design, sample demographics, and the specific covariates considered. Fewer studies identified a significant association between substance use and gun access/possession than other gun activities. The significant association between nonsubstance covariates (e.g., demographic covariates and other behavioral risk factors) and gun-related behaviors might have moderated the association between substance use and gun activities. Particularly, the strength of association between substance use and gun activities tended to reduce appreciably or to become nonsignificant after adjustment for mental disorders. Some studies indicated a positive association between the frequency of substance use and the odds of engaging in gun-related behaviors. Overall, the results suggest a need to consider substance use in research and prevention programs for gun-related violence. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Trends in BB/pellet gun injuries in children and teenagers in the United States, 1985-99.

    PubMed

    Nguyen, M H; Annest, J L; Mercy, J A; Ryan, G W; Fingerhut, L A

    2002-09-01

    To characterize national trends in non-fatal BB/pellet gun related injury rates for persons aged 19 years or younger in relation to trends in non-fatal and fatal firearm related injury rates and discuss these trends in light of injury prevention and violence prevention efforts. The National Electronic Injury Surveillance System (NEISS) includes approximately 100 hospitals with at least six beds that provide emergency services. These hospitals comprise a stratified probability sample of all US hospitals with emergency departments. The National Vital Statistics System (NVSS) is a complete census of all death certificates filed by states and is compiled annually. National data on BB/pellet gun related injuries and injury rates were examined along with fatal and non-fatal firearm related injuries and injury rates. Non-fatal injury data for all BB/pellet gun related injury cases from 1985 through 1999, and firearm related injury cases from 1993 through 1999 were obtained from hospital emergency department records using the NEISS. Firearm related deaths from 1985 through 1999 were obtained from the NVSS. BB/pellet gun related injury rates increased from age 3 years to a peak at age 13 years and declined thereafter. In contrast, firearm related injury and death rates increased gradually until age 13 and then increased sharply until age 18 years. For persons aged 19 years and younger, BB/pellet gun related injury rates increased from the late 1980s until the early 1990s and then declined until 1999; these injury rates per 100 000 population were 24.0 in 1988, 32.8 in 1992, and 18.3 in 1999. This trend was similar to those for fatal and non-fatal firearm related injury rates per 100 000 which were 4.5 in 1985, 7.8 in 1993, and 4.3 in 1999 (fatal) and 38.6 in 1993 and 16.3 in 1999 (non-fatal). In 1999, an estimated 14 313 (95% confidence interval (CI) 12 025 to 16 601) cases with non-fatal BB/pellet gun injuries and an estimated 12 748 (95% CI 7881-17 615) cases with non

  4. Nail gun injuries among construction workers.

    PubMed

    Dement, John M; Lipscomb, Hester; Li, Leiming; Epling, Carol; Desai, Tejas

    2003-05-01

    Pneumatic nail guns greatly increase worker productivity and are extensively used in wood frame building construction, with especially high use in residential construction. One surveillance report of nail gun injuries in Washington State has been published; however, other literature consists largely of case reports and case series in trauma journals. The major objective of the current study was to investigate the occurrence of nail gun-associated injuries among construction workers and to identify preventable work-related factors associated with these injuries. Nail gun-related injuries occurring among a cohort of 13,347 carpenters in Ohio who worked union hours during the time period January 1, 1994, until September 30, 1997, were identified by matching the cohort with workers' compensation claims made to the Ohio Bureau of Workers' Compensation. We also analyzed workers' compensation claims for North Carolina Home Builders Association members for the period July 1996-November 1999 to identify nail gun-related injuries. Analyses included stratified analyses of claims by nature and body part injured, calculation of nail gun injury rates, and analyses of free text descriptions of injuries. Overall, nail gun injuries were responsible for 3.9 percent of workers' compensation claims with 8.3 percent to 25.5 percent of claims involving paid lost work time. The overall rate of nail gun injuries (cases per 200,000 work hours) was 0.33 in North Carolina and 0.26 in Ohio, reflecting the greater concentration of wood frame construction workers in the North Carolina population studied. Higher rates of injury were observed for carpenters in North Carolina and among residential carpenters in Ohio. The predominant body part injured was the hands/fingers, with 80 to 89 percent of injuries being nail punctures. Analyses of free text information for puncture injuries found approximately 70 percent of injuries to occur during the framing/sheathing stage of construction. Our data

  5. Accelerated Electron-Beam Formation with a High Capture Coefficient in a Parallel Coupled Accelerating Structure

    NASA Astrophysics Data System (ADS)

    Chernousov, Yu. D.; Shebolaev, I. V.; Ikryanov, I. M.

    2018-01-01

    An electron beam with a high (close to 100%) coefficient of electron capture into the regime of acceleration has been obtained in a linear electron accelerator based on a parallel coupled slow-wave structure, electron gun with microwave-controlled injection current, and permanent-magnet beam-focusing system. The high capture coefficient was due to the properties of the accelerating structure, beam-focusing system, and electron-injection system. Main characteristics of the proposed systems are presented.

  6. Brief use of a specific gun in a violent game does not affect attitudes towards that gun

    PubMed Central

    Engelhardt, Christopher R.; Bartholow, Bruce D.

    2016-01-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates (N = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures. PMID:28018611

  7. Brief use of a specific gun in a violent game does not affect attitudes towards that gun.

    PubMed

    Hilgard, Joseph; Engelhardt, Christopher R; Bartholow, Bruce D

    2016-11-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates ( N  = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures.

  8. Guns on Campus: The Architecture and Momentum of State Policy Action

    ERIC Educational Resources Information Center

    Morse, Andrew; Sisneros, Lauren; Perez, Zeke; Sponsler, Brian A.

    2016-01-01

    "Guns on Campus: The Architecture and Momentum of State Policy Action" offers a detailed summary of state legislative action and higher education system policy decisions that have occurred in two specific categories: (1) States that have permitted or are seeking to permit guns on campus; and (2) States that have prohibited or are seeking…

  9. Failure Surfaces for the Design of Ceramic-Lined Gun Tubes

    DTIC Science & Technology

    2004-12-01

    density than steel making them attractive candidates as gun tube liners . A new design approach is necessary to address the large variability in strength...systems. Having established the failure criterion for the ceramic liner as the Weibull probability of failure, the need for a suitable failure...Report AMMRC SP-82-1, Materials Technology Laboratory, Watertown, Massachusetts, 1982. 7 R. Katz, Ceramic Gun Barrel Liners : Retrospect and Prospect

  10. Implementing Domestic Violence Gun Confiscation Policy in Rural and Urban Communities: Assessing the Perceived Risk, Benefits, and Barriers.

    PubMed

    Lynch, Kellie R; Logan, T K

    2017-07-01

    The purpose of this study was to gain a deeper understanding of why communities differing in culture and resources are willing and able to implement gun confiscation as part of a protective order in the absence of a uniform statewide gun law. Specifically, the perceived risk of intimate partner homicide and gun violence, effectiveness of implementing gun confiscation, and the barriers to implementing gun confiscation were assessed. Interviews were conducted with key community professionals ( N = 133) who worked in victim services and the justice system in one urban community and four rural, under-resourced communities. Analyses revealed that professionals in the rural communities viewed the risk of intimate partner homicide and gun violence as lower, and the process of implementing gun confiscation as less effective than professionals in the urban community. In addition, urban justice system professionals, in comparison with all other professionals, reported fewer barriers to enforcing the gun confiscation police and were more likely to downplay law enforcement limitations in the community. The results have implications for developing more effective regional strategies in states that lack domestic violence gun laws as a means to increase a community's ability to enforce gun policies and initiatives.

  11. On Intelligent Design and Planning Method of Process Route Based on Gun Breech Machining Process

    NASA Astrophysics Data System (ADS)

    Hongzhi, Zhao; Jian, Zhang

    2018-03-01

    The paper states an approach of intelligent design and planning of process route based on gun breech machining process, against several problems, such as complex machining process of gun breech, tedious route design and long period of its traditional unmanageable process route. Based on gun breech machining process, intelligent design and planning system of process route are developed by virtue of DEST and VC++. The system includes two functional modules--process route intelligent design and its planning. The process route intelligent design module, through the analysis of gun breech machining process, summarizes breech process knowledge so as to complete the design of knowledge base and inference engine. And then gun breech process route intelligently output. On the basis of intelligent route design module, the final process route is made, edited and managed in the process route planning module.

  12. GUN4-Porphyrin Complexes Bind the ChlH/GUN5 Subunit of Mg-Chelatase and Promote Chlorophyll Biosynthesis in Arabidopsis[W

    PubMed Central

    Adhikari, Neil D.; Froehlich, John E.; Strand, Deserah D.; Buck, Stephanie M.; Kramer, David M.; Larkin, Robert M.

    2011-01-01

    The GENOMES UNCOUPLED4 (GUN4) protein stimulates chlorophyll biosynthesis by activating Mg-chelatase, the enzyme that commits protoporphyrin IX to chlorophyll biosynthesis. This stimulation depends on GUN4 binding the ChlH subunit of Mg-chelatase and the porphyrin substrate and product of Mg-chelatase. After binding porphyrins, GUN4 associates more stably with chloroplast membranes and was proposed to promote interactions between ChlH and chloroplast membranes—the site of Mg-chelatase activity. GUN4 was also proposed to attenuate the production of reactive oxygen species (ROS) by binding and shielding light-exposed porphyrins from collisions with O2. To test these proposals, we first engineered Arabidopsis thaliana plants that express only porphyrin binding–deficient forms of GUN4. Using these transgenic plants and particular mutants, we found that the porphyrin binding activity of GUN4 and Mg-chelatase contribute to the accumulation of chlorophyll, GUN4, and Mg-chelatase subunits. Also, we found that the porphyrin binding activity of GUN4 and Mg-chelatase affect the associations of GUN4 and ChlH with chloroplast membranes and have various effects on the expression of ROS-inducible genes. Based on our findings, we conclude that ChlH and GUN4 use distinct mechanisms to associate with chloroplast membranes and that mutant alleles of GUN4 and Mg-chelatase genes cause sensitivity to intense light by a mechanism that is potentially complex. PMID:21467578

  13. Feasibility and acceptability of interventions to delay gun access in VA mental health settings.

    PubMed

    Walters, Heather; Kulkarni, Madhur; Forman, Jane; Roeder, Kathryn; Travis, Jamie; Valenstein, Marcia

    2012-01-01

    The majority of VA patient suicides are completed with firearms. Interventions that delay patients' gun access during high-risk periods may reduce suicide, but may not be acceptable to VA stakeholders or may be challenging to implement. Using qualitative methods, stakeholders' perceptions about gun safety and interventions to delay gun access during high-risk periods were explored. Ten focus groups and four individual interviews were conducted with key stakeholders, including VA mental health patients, mental health clinicians, family members and VA facility leaders (N=60). Transcripts were consensus-coded by two independent coders, and structured summaries were developed and reviewed using a consensus process. All stakeholder groups indicated that VA health system providers had a role in increasing patient safety and emphasized the need for providers to address gun access with their at-risk patients. However, VA mental health patients and clinicians reported limited discussion regarding gun access in VA mental health settings during routine care. Most, although not all, patients and clinicians indicated that routine screening for gun access was acceptable, with several noting that it was more acceptable for mental health patients. Most participants suggested that family and friends be involved in reducing gun access, but expressed concerns about potential family member safety. Participants generally found distribution of trigger locks acceptable, but were skeptical about its effectiveness. Involving Veteran Service Organizations or other individuals in temporarily holding guns during high-risk periods was acceptable to many participants but only with numerous caveats. Patients, clinicians and family members consider the VA health system to have a legitimate role in addressing gun safety. Several measures to delay gun access during high-risk periods for suicide were seen as acceptable and feasible if implemented thoughtfully. Published by Elsevier Inc.

  14. Background Checks for all Gun Buyers and Gun Violence Restraining Orders: State Efforts to Keep Guns from High-Risk Persons.

    PubMed

    Vernick, Jon S; Alcorn, Ted; Horwitz, Joshua

    2017-03-01

    There were more than 36,000 firearm-related deaths in the U.S. in 2015. Under federal law, a background check is required only for gun purchases from licensed dealers. Research suggests that some persons prohibited from owning a gun turn to private sellers, including those identified online, to attempt to obtain a firearm. State-level approaches to make it more difficult for high-risk persons to purchase or possess firearms include universal background check (UBC) and gun violence restraining order (GVRO) laws. UBC laws, on the books in 18 states as of the end of 2016, can reduce both homicide and suicide rates. After Colorado adopted a UBC law in 2013, the number of background checks conducted by private sellers for sales occurring at places other than gun shows steadily increased. GVRO laws give law enforcement and families the authority to petition a court to temporarily remove firearms from an individual who presents a danger to himself or others during times of crisis, regardless of whether that person has been diagnosed with a mental illness. California enacted a GVRO law in 2014. Data are emerging to suggest the effectiveness of GVRO-type laws at averting suicides and providing an entryway to services.

  15. Cusp-Gun Sixth-Harmonic Slotted Gyrotron

    NASA Astrophysics Data System (ADS)

    Stutzman, R. C.; McDermott, D. B.; Hirata Luhmann, Y., Jr.; Gallagher, D. A.; Spencer, T. A.

    2000-10-01

    A high-harmonic slotted gyrotron has been constructed at UC Davis to be driven by a 70 kV, 3.5 A, axis-encircling electron beam from a Northrop Grumman Cusp gun. The 94 GHz, slotted sixth-harmonic gyrotron is predicted to generate 50 kW with an efficiency of 20%. Using the profile of the adiabatic field reversal from the UC Davis superconducting test-magnet, EGUN simulations predict that an axis-encircling electron beam will be generated with an axial velocity spread of Δ v_z/v_z=10% for the desired velocity ratio of α =v_z/v_z=1.5. The design will also be presented for an 8th-harmonic W-band gyrotron whose magnetic field can be supplied by a lightweight permanent magnet.

  16. NASA Researcher with a Coaxial Plasma Gun

    NASA Image and Video Library

    1962-06-21

    Researcher Charles Michels operates a coaxial plasma gun rig in Cell SW-13 of the Engine Research Building at the National Aeronautics and Space Administration (NASA) Lewis Research Center. From 1962 to 1967 NASA Lewis investigated coaxial plasma guns powered by conventional capacitor banks. The studies were part of a larger effort to identify electromagnetic accelerators for space propulsion. NASA worked with General Dynamics, General Electric, General Motors, and Republic Aviation on the project. NASA Lewis conducted a research program to determine which factors influenced the coaxial gun’s efficiency and analyze the acceleration process. The system had not previously been used for propulsion applications. The single-shot gun’s fast gas valve and capacitor banks with variable-delay ignition source permitted the evaluation of gun performance under controllable propellant quantity and distribution conditions. The coaxial plasma gun was the most basic type of electromagnetic accelerator. It included a charged capacitor in series with a pair of coaxial electrodes. An electrical breakdown occurred when gas was admitted to the inter-electrode region. The gas instantly became a good conductor and formed a conducting sheet that separated the magnetic field from the open region beyond. The highly-conducting gas was basically expelled by the force of the magnetic pressure. This type of thruster could operate at the high instantaneous power levels without decreasing its average power level.

  17. Commercialization of an S-band standing-wave electron accelerator for industrial applications

    NASA Astrophysics Data System (ADS)

    Moon, Jin-Hyeok; Kwak, Gyeong-Il; Han, Jae-Ik; Lee, Gyu-Baek; Jeon, Seong-Hwan; Kim, Jae-Young; Hwang, Cheol-Bin; Lee, Gi-Yong; Kim, Young-Man; Park, Sung-Ju

    2016-09-01

    An electron accelerator system has been developed for use in industrial, as well as possible medical, applications. Based on our experiences achieved during prototype system development and various electron beam acceleration tests, we have built a stable and compact system for sales purposes. We have integrated a self-developed accelerating cavity, an E-gun pulse driver, a radio-frequency (RF) power system, a vacuum system, a cooling system, etc. into a frame with a size of 1800 × 1000 × 1500 mm3. The accelerating structure is a side-coupled standing-wave type operating in the π/2 mode (tuned to~3 GHz). The RF power is provided by using a magnetron driven by a solid-state modulator. The electron gun is a triode type with a dispenser cathode (diameter of 11 mm). The system is capable of delivering a maximum 900-W average electron beam power with tight focusing at the target. Until now, we have performed various electron beam tests and X-ray beam tests after having built the system, have completed the beam assessment for commercializations, and have been preparing full-fledged sales activity. This article reports on our system development processes and on some of our early test results for commercializations.

  18. Extended suicide using an atypical stud gun.

    PubMed

    Hagemeier, L; Schyma, C; Madea, B

    2009-08-10

    Suicides with stud guns are uncommon, but are well documented in the literature. On rare occasions, stud guns are also used as a homicide weapon. This case report describes an extended suicide in which a husband killed his wife and their two dogs, which lived on the property. The husband then committed suicide with a shot from the stud gun into his skull. He was a 70-year-old pensioner, a retired butcher, who was found by his son. He was lying in a supine position on a carpet in the living room, with the stud gun stuck in his skull. During autopsy, high concentrations of an antihistamine were found in the blood of each corpse; this drug is used as a soporific. In contrast to the literature, which mainly describes powder deposits due to the use of conventional stud guns, in this case a stud gun was used in which the expanding gases and powder escaped together with the central bolt at the front of the device; powder drains were not involved. Detailed findings of the autopsy are given with reference to this type of stud gun.

  19. Ready, Fire, Aim: The College Campus Gun Fight

    ERIC Educational Resources Information Center

    Birnbaum, Robert

    2013-01-01

    The question of whether guns should be permitted on college and university campuses in the United States reflects the tension between two competing perspectives. America has both a robust gun culture and an equally robust (if less well known) gun-control culture. The gun culture is as American as apple pie: There may be as many as 300 million…

  20. In Situ observation of dark current emission in a high gradient rf photocathode gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shao, Jiahang; Shi, Jiaru; Antipov, Sergey P.

    Undesirable electron field emission (also known as dark current) in high gradient rf photocathode guns deteriorates the quality of the photoemission current and limits the operational gradient. To improve the understanding of dark current emission, a high-resolution (~100 μm) dark current imaging experiment has been performed in an L-band photocathode gun operating at ~100 MV/m of surface gradient. Scattered strong emission areas with high current have been observed on the cathode. The field enhancement factor β of selected regions on the cathode has been measured. Finally, the postexaminations with scanning electron microscopy and white light interferometry reveal the origins ofmore » ~75% strong emission areas overlap with the spots where rf breakdown has occurred.« less

  1. In Situ observation of dark current emission in a high gradient rf photocathode gun

    DOE PAGES

    Shao, Jiahang; Shi, Jiaru; Antipov, Sergey P.; ...

    2016-08-15

    Undesirable electron field emission (also known as dark current) in high gradient rf photocathode guns deteriorates the quality of the photoemission current and limits the operational gradient. To improve the understanding of dark current emission, a high-resolution (~100 μm) dark current imaging experiment has been performed in an L-band photocathode gun operating at ~100 MV/m of surface gradient. Scattered strong emission areas with high current have been observed on the cathode. The field enhancement factor β of selected regions on the cathode has been measured. Finally, the postexaminations with scanning electron microscopy and white light interferometry reveal the origins ofmore » ~75% strong emission areas overlap with the spots where rf breakdown has occurred.« less

  2. Higher-order mode rf guns

    NASA Astrophysics Data System (ADS)

    Lewellen, John W.

    2001-04-01

    Traditional photocathode rf gun design is based around the use of TM0,1,0-mode cavities. This is typically done in the interest of obtaining the highest possible gradient per unit supplied rf power and for historical reasons. In a multicell, aperture-coupled photoinjector, however, the gun as a whole is produced from strongly coupled cavities oscillating in a π mode. This design requires very careful preparation and tuning, as the field balance and resonant frequencies are easily disturbed. Side-coupled designs are often avoided because of the dipole modes introduced into the cavity fields. This paper proposes the use of a single higher-order mode rf cavity in order to generate the desired on-axis fields. It is shown that the field experienced by a beam in a higher-order mode rf gun is initially very similar to traditional 1.5- or 2.5-cell π-mode gun fields, and projected performance in terms of beam quality is also comparable. The new design has the advantages of much greater ease of fabrication, immunity from coupled-cell effects, and simpler tuning procedures. Because of the gun geometry, the possibility also exists for improved temperature stabilization and cooling for high duty-cycle applications.

  3. Electron beam machining using rotating and shaped beam power distribution

    DOEpatents

    Elmer, John W.; O'Brien, Dennis W.

    1996-01-01

    An apparatus and method for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: 1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and 2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1000 .mu.m (1 mm or larger), compared to the 250 .mu.m diameter of laser drilling.

  4. Cobalt-Base Alloy Gun Barrel Study

    DTIC Science & Technology

    2014-07-01

    Cobalt-Base Alloy Gun Barrel Study by William S. de Rosset and Jonathan S. Montgomery ARL-RP-0491 July 2014 A reprint...21005-5069 ARL-RP-0491 July 2014 Cobalt-Base Alloy Gun Barrel Study William S. de Rosset and Jonathan S. Montgomery Weapons and Materials... Gun Barrel Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) William S. de Rosset and Jonathan S. Montgomery

  5. Non-invasive timing of gas gun projectiles with light detection and ranging

    NASA Astrophysics Data System (ADS)

    Goodwin, P. M.; Bartram, B. D.; Gibson, L. L.; Wu, M.; Dattelbaum, D. M.

    2014-05-01

    We have developed a Light Detection and Ranging (LIDAR) diagnostic to track the position of a projectile inside of a gas gun launch tube in real-time. This capability permits the generation of precisely timed trigger pulses useful for triggering high-latency diagnostics such as a flash lamp-pumped laser. An initial feasibility test was performed using a 72 mm bore diameter single-stage gas gun routinely used for dynamic research at Los Alamos. A 655 nm pulsed diode laser operating at a pulse repetition rate of 100 kHz was used to interrogate the position of the moving projectile in real-time. The position of the projectile in the gun barrel was tracked over a distance of ~ 3 meters prior to impact. The position record showed that the projectile moved at a velocity of 489 m/s prior to impacting the target. This velocity was in good agreement with independent measurements of the projectile velocity by photon Doppler velocimetry and timing of the passage of the projectile through optical marker beams positioned at the muzzle of the gun. The time-to-amplitude conversion electronics used enable the LIDAR data to be processed in real-time to generate trigger pulses at preset separations between the projectile and target.

  6. Arc-driven rail gun research

    NASA Technical Reports Server (NTRS)

    Ray, P. K.

    1984-01-01

    The equations describing the performance of an inductively-driven rail gun are analyzed numerically. Friction between the projectile and rails is included through an empirical formulation. The equations are applied to the experiment of Rashleigh and Marshall to obtain an estimate of energy distribution in rail guns as a function of time. The effect of frictional heat dissipation on the bore of the gun is calculated. The mechanism of plasma and projectile acceleration in a dc rail gun is described from a microscopic point of view through the establishment of the Hall field. The plasma conductivity is shown to be a tensor indicating that there is a small component of current parallel to the direction of acceleration. The plasma characteristics are evaluated as a function of plasma mass through a simple fluid mechanical analysis of the plasma. By equating the energy dissipated in the plasma with the radiation heat loss, the properties of the plasma are determined.

  7. Trends in BB/pellet gun injuries in children and teenagers in the United States, 1985–99

    PubMed Central

    Nguyen, M; Annest, J; Mercy, J; Ryan, G; Fingerhut, L

    2002-01-01

    Objective: To characterize national trends in non-fatal BB/pellet gun related injury rates for persons aged 19 years or younger in relation to trends in non-fatal and fatal firearm related injury rates and discuss these trends in light of injury prevention and violence prevention efforts. Setting: The National Electronic Injury Surveillance System (NEISS) includes approximately 100 hospitals with at least six beds that provide emergency services. These hospitals comprise a stratified probability sample of all US hospitals with emergency departments. The National Vital Statistics System (NVSS) is a complete census of all death certificates filed by states and is compiled annually. Methods: National data on BB/pellet gun related injuries and injury rates were examined along with fatal and non-fatal firearm related injuries and injury rates. Non-fatal injury data for all BB/pellet gun related injury cases from 1985 through 1999, and firearm related injury cases from 1993 through 1999 were obtained from hospital emergency department records using the NEISS. Firearm related deaths from 1985 through 1999 were obtained from the NVSS. Results: BB/pellet gun related injury rates increased from age 3 years to a peak at age 13 years and declined thereafter. In contrast, firearm related injury and death rates increased gradually until age 13 and then increased sharply until age 18 years. For persons aged 19 years and younger, BB/pellet gun related injury rates increased from the late 1980s until the early 1990s and then declined until 1999; these injury rates per 100 000 population were 24.0 in 1988, 32.8 in 1992, and 18.3 in 1999. This trend was similar to those for fatal and non-fatal firearm related injury rates per 100 000 which were 4.5 in 1985, 7.8 in 1993, and 4.3 in 1999 (fatal) and 38.6 in 1993 and 16.3 in 1999 (non-fatal). In 1999, an estimated 14 313 (95% confidence interval (CI) 12 025 to 16 601) cases with non-fatal BB/pellet gun injuries and an estimated 12 748

  8. Gun ownership and firearm-related deaths.

    PubMed

    Bangalore, Sripal; Messerli, Franz H

    2013-10-01

    A variety of claims about possible associations between gun ownership rates, mental illness burden, and the risk of firearm-related deaths have been put forward. However, systematic data on this issue among various countries remain scant. Our objective was to assess whether the popular notion "guns make a nation safer" has any merits. Data on gun ownership were obtained from the Small Arms Survey, and for firearm-related deaths from a European detailed mortality database (World Health Organization), the National Center for Health Statistics, and others. Crime rate was used as an indicator of safety of the nation and was obtained from the United Nations Surveys of Crime Trends. Age-standardized disability-adjusted life-year rates due to major depressive disorder per 100,000 inhabitants with data obtained from the World Health Organization database were used as a putative indicator for mental illness burden in a given country. Among the 27 developed countries, there was a significant positive correlation between guns per capita per country and the rate of firearm-related deaths (r = 0.80; P <.0001). In addition, there was a positive correlation (r = 0.52; P = .005) between mental illness burden in a country and firearm-related deaths. However, there was no significant correlation (P = .10) between guns per capita per country and crime rate (r = .33), or between mental illness and crime rate (r = 0.32; P = .11). In a linear regression model with firearm-related deaths as the dependent variable with gun ownership and mental illness as independent covariates, gun ownership was a significant predictor (P <.0001) of firearm-related deaths, whereas mental illness was of borderline significance (P = .05) only. The number of guns per capita per country was a strong and independent predictor of firearm-related death in a given country, whereas the predictive power of the mental illness burden was of borderline significance in a multivariable model. Regardless of exact

  9. Mole gun injury.

    PubMed

    Pistré, V; Rezzouk, J

    2013-09-01

    A mole gun is a weapon, which is used to trap and kill moles. This report provides an overview of the state of knowledge of mole gun injuries, comparable to blast injuries caused by fireworks, explosive or gunshot. Over a 2-year period, the authors reported their experience with ten hand injuries caused by mole gun. Radial side of the hand was often concerned, particularly the thumb. The authors explain their choices in the management of such lesions. Surgery was performed primarily and a large debridement currently seemed to offer the best outcome for the patient. Blast, crush, burns and lacerations may explain the higher rate of amputation to the digits. A long period of physiotherapy, specifically of the hand, was needed before the patient could return to work. This ballistic hand trauma encountered by surgeons requires knowledge and understanding of these injuries. It should be in accordance with firearms law because of severe injuries encountered and possible lethal wounds. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  10. ANALYTICAL MODELING OF ELECTRON BACK-BOMBARDMENT INDUCED CURRENT INCREASE IN UN-GATED THERMIONIC CATHODE RF GUNS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edelen, J. P.; Sun, Y.; Harris, J. R.

    In this paper we derive analytical expressions for the output current of an un-gated thermionic cathode RF gun in the presence of back-bombardment heating. We provide a brief overview of back-bombardment theory and discuss comparisons between the analytical back-bombardment predictions and simulation models. We then derive an expression for the output current as a function of the RF repetition rate and discuss relationships between back-bombardment, fieldenhancement, and output current. We discuss in detail the relevant approximations and then provide predictions about how the output current should vary as a function of repetition rate for some given system configurations.

  11. Improved Orifice Plate for Spray Gun

    NASA Technical Reports Server (NTRS)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  12. Unintentional Gun Deaths among Children. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Children are at risk of being killed or injured by a gun if their parents own a gun because many guns obtained for self-defense are kept loaded and within reach of children. This brief fact sheet presents statistical information relating to accidental deaths involving young people and firearms. Safety measures are suggested for preventing…

  13. RF Design of a High Average Beam-Power SRF Electron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sipahi, Nihan; Biedron, Sandra; Gonin, Ivan

    2016-06-01

    There is a significant interest in developing high-average power electron sources, particularly in the area of electron sources integrated with Superconducting Radio Frequency (SRF) systems. For these systems, the electron gun and cathode parts are critical components for stable intensity and high-average powers. In this initial design study, we will present the design of a 9-cell accelerator cavity having a frequency of 1.3 GHz and the corresponding field optimization studies.

  14. Gun Launch System: efficient and low-cost means of research and real-time monitoring

    NASA Astrophysics Data System (ADS)

    Degtyarev, Alexander; Ventskovsky, Oleg; Korostelev, Oleg; Yakovenko, Peter; Kanevsky, Valery; Tselinko, Alexander

    2005-08-01

    The Gun Launch System with a reusable sub-orbital launch vehicle as a central element is proposed by a consortium of several Ukrainian high-tech companies as an effective, fast-response and low-cost means of research and real-time monitoring. The system is described in details, with the emphasis on its most important advantages. Multiple applications of the system are presented, including ones for the purposes of microgravity research; chemical, bacteriological and radiation monitoring and research of atmosphere and ionosphere; operational monitoring of natural and man-made disasters, as well as for some other areas of great practical interest. The current level of the system development is given, and the way ahead towards full system's implementation is prescribed.

  15. Frequency of Guns in the Households of High School Seniors*

    PubMed Central

    Coker, Ann L.; Bush, Heather M.; Follingstad, Diane R.; Brancato, Candace J.

    2017-01-01

    BACKGROUND In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. METHODS In this cohort study of 3006 high school seniors from 24 schools, we examined the frequency of household guns ownership. RESULTS About 65% reported having at least 1 gun in their household. White males were more likely to have a gun and to have more guns than other demographically characterized groups. After adjustment for race and sex, those of higher income, who lived in suburban or rural areas, identified as being exclusively attracted to the opposite sex, and in a romantic relationship, were more likely to have a gun in their household. Having a gun was not associated with increasing symptoms of depression or current poor physical or mental health. CONCLUSIONS Whereas we cannot determine gun types or reasons for having a gun, this research indicates that high school seniors are aware of and may have access to guns for use other than their intended purpose. Household gun ownership among students at higher risk for violence may pose safety challenges for communities and schools. PMID:28147456

  16. Frequency of Guns in the Households of High School Seniors.

    PubMed

    Coker, Ann L; Bush, Heather M; Follingstad, Diane R; Brancato, Candace J

    2017-03-01

    In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. In this cohort study of 3006 high school seniors from 24 schools, we examined the frequency of household guns ownership. About 65% reported having at least 1 gun in their household. White males were more likely to have a gun and to have more guns than other demographically characterized groups. After adjustment for race and sex, those of higher income, who lived in suburban or rural areas, identified as being exclusively attracted to the opposite sex, and in a romantic relationship, were more likely to have a gun in their household. Having a gun was not associated with increasing symptoms of depression or current poor physical or mental health. Whereas we cannot determine gun types or reasons for having a gun, this research indicates that high school seniors are aware of and may have access to guns for use other than their intended purpose. Household gun ownership among students at higher risk for violence may pose safety challenges for communities and schools. © 2017, American School Health Association.

  17. Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments.

    PubMed

    Ii, Toru; Gi, Keii; Umezawa, Toshiyuki; Asai, Tomohiko; Inomoto, Michiaki; Ono, Yasushi

    2012-08-01

    We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

  18. "Gun-shooting hearing loss": A pilot study.

    PubMed

    Sataloff, Joseph; Hawkshaw, Mary J; Sataloff, Robert T

    2010-01-01

    Gun-shooting deafness is the common terminology applied to sensorineural hearing loss caused by shooting firearms. Many characteristics of gun-shooting hearing loss have been proposed, but they have not been defined clearly or established conclusively. We studied 37 users of recreational firearms to obtain pilot data to help determine if it is true that right-handed gun shooters develop more hearing loss in the left ear and vice versa, whether everyone who frequently shoots guns develops sensorineural hearing loss, and whether significant hearing loss is typically prevented by wearing commercially available ear protectors while shooting.

  19. Control of the Helicity Content of a Gun-Generated Spheromak by Incorporating a Conducting Shell into a Magnetized Coaxial Plasma Gun

    NASA Astrophysics Data System (ADS)

    Matsumoto, Tadafumi; Sekiguchi, Jun'ichi; Asai, Tomohiko

    In the formation of magnetized plasmoid by a magnetized coaxial plasma gun (MCPG), the magnetic helicity content of the generated plasmoid is one of the critical parameters. Typically, the bias coil to generate a poloidal flux is mounted either on the outer electrode or inside the inner electrode. However, most of the flux generated in the conventional method spreads even radially outside of the formation region. Thus, only a fraction of the total magnetic flux is actually exploited for helicity generation in the plasmoid. In the proposed system, the plasma gun incorporates a copper shell mounted on the outer electrode. By changing the rise time of the discharge bias coil current and the geometrical structure of the shell, the magnetic field structure and its time evolution can be controlled. The effect of the copper shell has been numerically simulated for the actual gun structure, and experimentally confirmed. This may increase the magnetic helicity content results, through increased poloidal magnetic field.

  20. Patterns of gun deaths across US counties 1999-2013.

    PubMed

    Kalesan, Bindu; Galea, Sandro

    2017-05-01

    We examined the socio-demographic distribution of gun deaths across 3143 counties in 50 United States' states to understand the spatial patterns and correlates of high and low gun deaths. We used aggregate counts of gun deaths and population in all counties from 1999 to 2013 from the Centers for Disease Control and Prevention's Wide-ranging Online Data for Epidemiologic Research (WONDER). We characterized four levels of gun violence, as distinct levels of gun death rates of relatively safe, unsafe, violent, and extremely violent counties, based on quartiles of 15-year county-specific gun death rates per 100,000 and used negative binomial regression models allowing clustering by state to calculate incidence rate ratios and 95% confidence intervals (95% CIs). Most states had at least one violent or extremely violent county. Extremely violent gun counties were mostly rural, poor, predominantly minority, had high unemployment rate and homicide rate. Overall, homicide rate was significantly associated with gun deaths (incidence rate ratios = 1.08, 95% CI = 1.06-1.09). In relatively safe counties, this risk was 1.09 (95% CI = 1.05-1.13) and in extremely violent gun counties was 1.03 (95% CI = 1.03-1.04). There are broad differences in gun death rates across the United States representing different levels of gun death rates in each state with distinct socio-demographic profiles. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Transverse profile of the electron beam for the RHIC electron lenses

    DOE PAGES

    Gu, X.; Altinbas, Z.; Costanzo, M.; ...

    2015-07-10

    To compensate for the beam-beam effects from the proton-proton interactions at the two interaction points IP6 and IP8 in the Relativistic Heavy Ion Collider (RHIC), we are constructing two electron lenses (e-lenses) that we plan to install in the interaction region IR10. Before installing them, the electron gun, collector, instrumentation were tested and the electron beam properties were qualified on an electron lens test bench. We will present the test results and discuss our measurement of the electron beam current and of the electron gun perveance. We achieved a maximum current of 1 A with 5 kV energy for bothmore » the pulsed- and the DC-beam (which is a long turn-by-turn pulse beam). We measured beam transverse profiles with an Yttrium Aluminum Garnet (YAG) screen and pinhole detector, and compared those to simulated beam profiles. Measurements of the pulsed electron beam stability were obtained by measuring the modulator voltage.« less

  2. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    PubMed Central

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  3. Acute alcohol consumption, alcohol outlets, and gun suicide.

    PubMed

    Branas, Charles C; Richmond, Therese S; Ten Have, Thomas R; Wiebe, Douglas J

    2011-01-01

    A case-control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed.

  4. Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

    NASA Astrophysics Data System (ADS)

    Zhao, Jifei; Lu, Xiangyang; Zhou, Kui; Yang, Ziqin; Yang, Deyu; Luo, Xing; Tan, Weiwei; Yang, Yujia

    2016-06-01

    As an important electron source, Micro-Pulse electron Gun (MPG) which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR), Free Electron Laser (FEL). The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY) curve was introduced. The self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC) effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.

  5. Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Jifei; Lu, Xiangyang, E-mail: xylu@pku.edu.cn; Yang, Ziqin

    As an important electron source, Micro-Pulse electron Gun (MPG) which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR), Free Electron Laser (FEL). The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY) curve was introduced. Themore » self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC) effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.« less

  6. Numerical Simulation of a Double-anode Magnetron Injection Gun for 110 GHz, 1 MW Gyrotron

    NASA Astrophysics Data System (ADS)

    Singh, Udaybir; Kumar, Nitin; Purohit, L. P.; Sinha, Ashok K.

    2010-07-01

    A 40 A double-anode magnetron injection gun for a 1 MW, 110 GHz gyrotron has been designed. The preliminary design has been obtained by using some trade-off equations. The electron beam analysis has been performed by using the commercially available code EGUN and the in-house developed code MIGANS. The operating mode of the gyrotron is TE22,6 and it is operated in the fundamental harmonic. The electron beam with a low transverse velocity spread ( δ {β_{ bot max }} = 2.26% ) and the transverse-to-axial velocity ratio of the electron beam (α) = 1.37 is obtained. The simulated results of the MIG obtained with the EGUN code have been validated with another trajectory code TRAK. The results on the design output parameters obtained by both the codes are in good agreement. The sensitivity analysis has been carried out by changing the different gun parameters to decide the fabrication tolerance.

  7. Separating Batterers and Guns: A Review and Analysis of Gun Removal Laws in 50 States

    ERIC Educational Resources Information Center

    Frattaroli, Shannon; Vernick, Jon S.

    2006-01-01

    Firearms play an important role in lethal domestic violence incidents. The authors review state laws regarding two policies to separate batterers from firearms: laws authorizing police to remove firearms when responding to a domestic violence complaint ("police gun removal laws") and laws authorizing courts to order guns removed from batterers…

  8. Spot-Welding Gun Is Easy To Use

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E.; Nguyen, Francis H.

    1991-01-01

    Electrical-resistance spot-welding gun designed to produce more welds per unit time by decreasing technician's effort and fatigue. Vacuum cups on frame secure welding gun to workpiece while compressed air drives welding tip against workpiece to make spot resistance weld. When weld completed, vacuum in frame cups released so frame and gun moved to position of next spot weld.

  9. Injector for the University of Maryland Electron Ring (UMER)

    NASA Astrophysics Data System (ADS)

    Kehne, D.; Godlove, T.; Haldemann, P.; Bernal, S.; Guharay, S.; Kishek, R.; Li, Y.; O'Shea, P.; Reiser, M.; Yun, V.; Zou, Y.; Haber, I.

    2001-05-01

    The electron beam injector constructed by FM technologies for the University of Maryland Electron Ring (UMER) program is described. The program will use an electron beam to model space-charge-dominated ion beams in a recirculating linac for heavy ion inertial fusion, as well as for high-current muon colliders. The injector consists of a 10 keV, 100 mA electron gun with 50-100 nsec pulse width and a repetition rate of 120 Hz. The e-gun system includes a 6-mask, rotatable aperture plate, a Rogowski current monitor, an ion pump, and a gate valve. The injector beamline consists of a solenoid, a five-quadrupole matching section, two diagnostic chambers, and a fast current monitor. An independent diagnostic chamber also built for UMER will be used to measure horizontal and vertical emittance, current, energy, energy spread, and the evolution of the beam envelope and profile along the injector beamline.

  10. A Low Velocity 0.30-cal. Gun System

    DTIC Science & Technology

    2015-02-01

    control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) February 2015 2. REPORT TYPE Final 3. DATES COVERED...298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 iii Contents List of Figures iv List of Tables iv 1. Introduction 1 2. Approach 4 3...the speed of sound in air. It is exceedingly difficult to get precise velocity control of gun-fired FSPs in this velocity regime using a

  11. NASA-Ames vertical gun

    NASA Technical Reports Server (NTRS)

    Schultz, P. H.

    1984-01-01

    A national facility, the NASA-Ames vertical gun range (AVGR) has an excellent reputation for revealing fundamental aspects of impact cratering that provide important constraints for planetary processes. The current logistics in accessing the AVGR, some of the past and ongoing experimental programs and their relevance, and the future role of this facility in planetary studies are reviewed. Publications resulting from experiments with the gun (1979 to 1984) are listed as well as the researchers and subjects studied.

  12. Electron beam observation opportunity

    NASA Astrophysics Data System (ADS)

    Raitt, John; Banks, Peter

    Ionospheric researchers will have the opportunity to conduct coordinated radio, radar, and optical observations in conjunction with other space-based electron beam experiments as part of the upcoming Cooperative High-Altitude Rocket Gun Experiments (CHARGE) 3 rocket flight in November 1988 at White Sands Missile Range (WSMR, White Sands, N.Mex.). The flight will be particularly interesting because of the high power planned for the electron gun (3.5 kV at 5 A), which is based, in part, on technology developments planned for the successful Excede series of rockets.CHARGE 3 is the third in a series of U.S. flights made in collaboration with investigators from Utah State University (Logan), Stanford University (Stanford, Calif.), the Institute for Space and Astronautical Sciences (Sendai, Japan), and the University of Michigan (Ann Arbor). The general objectives for CHARGE 3 are fourfold: to study vehicle charging and diagnosecontributory effects at higher beam currents and energy,to study ELF/VLF wave generation and propagation from dc and modulated electron beams,to diagnose beam propagation remotely by studying E region ionization and optical excitation, andto investigate voltage and current distribution in an electrically tethered space vehicle system at higher beam currents.

  13. Space Charge Effect in the Sheet and Solid Electron Beam

    NASA Astrophysics Data System (ADS)

    Song, Ho Young; Kim, Hyoung Suk; Ahn, Saeyoung

    1998-11-01

    We analyze the space charge effect of two different types of electron beam ; sheet and solid electron beam. Electron gun simulations are carried out using shadow and control grids for high and low perveance. Rectangular and cylindrical geometries are used for sheet and solid electron beam in planar and disk type cathode. The E-gun code is used to study the limiting current and space charge loading in each geometries.

  14. Generation of magneto-immersed electron beams

    NASA Astrophysics Data System (ADS)

    Pikin, A.; Raparia, D.

    2018-05-01

    There are many applications of electron beams in accelerator facilities: for electron coolers, electron lenses, and electron beam ion sources (EBIS) to mention a few. Most of these applications require magnetic compression of the electron beam to reduce the beam radius with the goal of either matching the circulating ion beam (electron lenses and electron coolers) or increasing the ionization capability for the production of highly charged ions (EBIS). The magnetic compression of the electron beam comes at a cost of increasing share of the transverse component of energy and therefore increased angles of the electron trajectories to the longitudinal axis. Considering the effect of the magnetic mirror, it is highly desirable to produce a laminar electron beam in the electron gun. The analysis of electron guns with different configurations is given in this paper with emphasis on generating laminar electron beams.

  15. Electron beam machining using rotating and shaped beam power distribution

    DOEpatents

    Elmer, J.W.; O`Brien, D.W.

    1996-07-09

    An apparatus and method are disclosed for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: (1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and (2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1,000 {micro}m (1 mm or larger), compared to the 250 {micro}m diameter of laser drilling. 5 figs.

  16. Sequential injection gas guns for accelerating projectiles

    DOEpatents

    Lacy, Jeffrey M [Idaho Falls, ID; Chu, Henry S [Idaho Falls, ID; Novascone, Stephen R [Idaho Falls, ID

    2011-11-15

    Gas guns and methods for accelerating projectiles through such gas guns are described. More particularly, gas guns having a first injection port located proximate a breech end of a barrel and a second injection port located longitudinally between the first injection port and a muzzle end of the barrel are described. Additionally, modular gas guns that include a plurality of modules are described, wherein each module may include a barrel segment having one or more longitudinally spaced injection ports. Also, methods of accelerating a projectile through a gas gun, such as injecting a first pressurized gas into a barrel through a first injection port to accelerate the projectile and propel the projectile down the barrel past a second injection port and injecting a second pressurized gas into the barrel through the second injection port after passage of the projectile and to further accelerate the projectile are described.

  17. Toroid Joining Gun For Fittings And Couplings

    NASA Technical Reports Server (NTRS)

    Fox, Robert L.; Swaim, Robert J.; Johnson, Samuel D.; Buckley, John D.; Copeland, Carl E.; Coultrip, Robert H.; Johnston, David F.; Phillips, William M.

    1992-01-01

    Hand-held gun used to join metal heat-to-shrink couplings. Uses magnetic induction (eddy currents) to produce heat in metal coupling, and thermocouple to measure temperature and signals end of process. Gun, called "toroid joining gun" concentrates high levels of heat in localized areas. Reconfigured for use on metal heat-to-shrink fitting and coupling applications. Provides rapid heating, operates on low power, lightweight and portable. Safe for use around aircraft fuel and has no detrimental effects on surrounding surfaces or objects. Reliable in any environment and under all weather conditions. Gun logical device for taking full advantage of capabilities of new metal heat-to-shrink couplings and fittings.

  18. Gun Concerns Personal for Duncan

    ERIC Educational Resources Information Center

    McNeil, Michele

    2013-01-01

    As U.S. Secretary of Education Arne Duncan works with other Obama administration officials on policy responses to the shootings at a Connecticut elementary school, he brings a personal and professional history that has acquainted him with the impact of gun violence. As schools chief in Chicago from 2001 to 2008, he was affected by the gun deaths…

  19. Demonstration of cathode emittance dominated high bunch charge beams in a DC gun-based photoinjector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gulliford, Colwyn, E-mail: cg248@cornell.edu; Bartnik, Adam, E-mail: acb20@cornell.edu; Bazarov, Ivan

    We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (≥100 pC) beams produced in the DC gun-based Cornell energy recovery linac photoinjector. In particular, we show that the cathode thermal and core beam emittances dominate the final 95% and core emittances measured at 9–9.5 MeV. Additionally, we demonstrate excellent agreement between optimized 3D space charge simulations and measurement, and show that the quality of the transverse laser distribution limits the optimal simulated and measured emittances. These results, previously thought achievable only with RF guns, demonstrate that DC gun based photoinjectors are capable of deliveringmore » beams with sufficient single bunch charge and beam quality suitable for many current and next generation accelerator projects such as Energy Recovery Linacs and Free Electron Lasers.« less

  20. Injection of a coaxial-gun-produced magnetized plasma into a background helicon plasma

    NASA Astrophysics Data System (ADS)

    Zhang, Yue; Lynn, Alan; Gilmore, Mark; Hsu, Scott

    2014-10-01

    A compact coaxial plasma gun is employed for experimental investigation of plasma bubble relaxation into a lower density background plasma. Experiments are being conducted in the linear device HelCat at UNM. The gun is powered by a 120-uF ignitron-switched capacitor bank, which is operated in a range of 5 to 10 kV and 100 kA. Multiple diagnostics are employed to investigate the plasma relaxation process. Magnetized argon plasma bubbles with velocities 1.2Cs, densities 1020 m-3 and electron temperature 13eV have been achieved. The background helicon plasma has density 1013 m-3, magnetic field from 200 to 500 Gauss and electron temperature 1eV. Several distinct operational regimes with qualitatively different dynamics are identified by fast CCD camera images. Additionally a B-dot probe array has been employed to measure the spatial toroidal and poloidal magnetic flux evolution to identify plasma bubble configurations. Experimental data and analysis will be presented.

  1. Gun Safety Management with Patients at Risk for Suicide

    ERIC Educational Resources Information Center

    Simon, Robert I.

    2007-01-01

    Guns in the home are associated with a five-fold increase in suicide. All patients at risk for suicide must be asked if guns are available at home or easily accessible elsewhere, or if they have intent to buy or purchase a gun. Gun safety management requires a collaborative team approach including the clinician, patient, and designated person…

  2. Design of a high-bunch-charge 112-MHz superconducting RF photoemission electron source

    NASA Astrophysics Data System (ADS)

    Xin, T.; Brutus, J. C.; Belomestnykh, Sergey A.; Ben-Zvi, I.; Boulware, C. H.; Grimm, T. L.; Hayes, T.; Litvinenko, Vladimir N.; Mernick, K.; Narayan, G.; Orfin, P.; Pinayev, I.; Rao, T.; Severino, F.; Skaritka, J.; Smith, K.; Than, R.; Tuozzolo, J.; Wang, E.; Xiao, B.; Xie, H.; Zaltsman, A.

    2016-09-01

    High-bunch-charge photoemission electron-sources operating in a continuous wave (CW) mode are required for many advanced applications of particle accelerators, such as electron coolers for hadron beams, electron-ion colliders, and free-electron lasers. Superconducting RF (SRF) has several advantages over other electron-gun technologies in CW mode as it offers higher acceleration rate and potentially can generate higher bunch charges and average beam currents. A 112 MHz SRF electron photoinjector (gun) was developed at Brookhaven National Laboratory to produce high-brightness and high-bunch-charge bunches for the coherent electron cooling proof-of-principle experiment. The gun utilizes a quarter-wave resonator geometry for assuring beam dynamics and uses high quantum efficiency multi-alkali photocathodes for generating electrons.

  3. Law Enforcement and Gun Retailers as Partners for Safely Storing Guns to Prevent Suicide: A Study in 8 Mountain West States.

    PubMed

    Runyan, Carol W; Brooks-Russell, Ashley; Brandspigel, Sara; Betz, Marian; Tung, Gregory; Novins, Douglas; Agans, Robert

    2017-11-01

    To examine the extent to which law enforcement agencies (LEAs) and gun retailers are willing to offer voluntary, temporary storage as a part of an overall suicide prevention effort. We invited all LEAs and gun retailers in 8 US states to respond to questionnaires asking about their willingness to offer temporary gun storage and their recommendations to gun owners about safe storage. We collected data in 2016 from 448 LEAs and 95 retailers (response rates of 53% and 25%, respectively). Three quarters of LEAs (74.8%; 95% confidence interval [CI] = 72.1, 77.5) indicated they already provided temporary storage compared with 47.6% (95% CI = 39.2, 56.0) of retailers. LEAs were most willing to provide storage when a gun owner was concerned about the mental health of a family member. Retailers were more receptive than were LEAs to providing storage when visitors were coming or for people wanting storage while traveling. Both groups recommended locking devices within the home, but LEAs were slightly more favorable to storing guns away from the home. Law enforcement agencies and gun retailers are important resources for families concerned about suicide.

  4. An overview of beam diagnostic and control systems for 50 MeV AREAL Linac

    NASA Astrophysics Data System (ADS)

    Sargsyan, A. A.; Amatuni, G. A.; Sahakyan, V. V.; Zanyan, G. S.; Martirosyan, N. W.; Vardanyan, V. V.; Grigoryan, B. A.

    2017-03-01

    Advanced Research Electron Accelerator Laboratory (AREAL) is an electron linear accelerator project with a laser driven RF gun being constructed at CANDLE Synchrotron Research Institute. After the successful operation of the gun section at 5 MeV, a program of facility energy enhancement up to 50 MeV is launched. In this paper the current status of existing diagnostic and control systems, as well as the results of electron beam parameter measurements are presented. The approaches of intended diagnostic and control systems for the upgrade program are also described.

  5. Stimulated Electron Desorption Studies from Microwave Vacuum Electronics / High Power Microwave Materials

    DTIC Science & Technology

    2010-02-11

    purchase a new gun. Mr. Mike Ackeret ( Transfer Engineering Inc.) Transfer Engineering’s expertise in specialty UHV work and machining propelled...modifications they helped design for the test stand. With UNLV guidance, Transfer Engineering designed and built the original UNLV SEE Test Stand...Staib electron gun, an isolated beam drift tube, a hexanode delay line with a chevron microchannel plate (MCP) stack, an isolated grid, an isolated

  6. Utility of indices of gun availability in the community.

    PubMed

    Shenassa, Edmond D; Daskalakis, Constantine; Buka, Stephen L

    2006-01-01

    To estimate the degree to which the proportion of homicides and suicides committed with a gun is associated with reported availability of firearms across Chicago neighbourhoods. Data were collected as part of the Project on Human Development in Chicago Neighborhoods (PHDCN), a combined neighbourhood and individual level study of the city of Chicago. The study used data from 837 PHDCN participants between the ages of 17 and 22, residing in 170 different neighbourhoods. Gun availability was measured via participant reports on whether they had carried a gun and whether they perceived gun access to be easy in their community. Data on suicides and homicides were obtained from the Chicago Department of Health. A 10% change in the proportion of homicides committed by a gun in a neighbourhood was associated with a 20% increase in both the odds of reported gun access and reported gun carrying (p=0.002 and 0.048, respectively). The proportion of firearm related suicides was not associated with either of those self reported measures. The proportion of firearm related homicides, but not the proportion of firearm related suicides, is a useful predictor of gun availability across small areas such as neighbourhoods.

  7. TiN coated aluminum electrodes for DC high voltage electron guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mamun, Md Abdullah A.; Elmustafa, Abdelmageed A.; Taus, Rhys

    Preparing electrodes made of metals like stainless steel, for use inside DC high voltage electron guns, is a labor-intensive and time-consuming process. In this paper, the authors report the exceptional high voltage performance of aluminum electrodes coated with hard titanium nitride (TiN). The aluminum electrodes were comparatively easy to manufacture and required only hours of mechanical polishing using silicon carbide paper, prior to coating with TiN by a commercial vendor. The high voltage performance of three TiN-coated aluminum electrodes, before and after gas conditioning with helium, was compared to that of bare aluminum electrodes, and electrodes manufactured from titanium alloymore » (Ti-6AI-4V). Following gas conditioning, each TiN-coated aluminum electrode reached -225 kV bias voltage while generating less than 100 pA of field emission (<10 pA) using a 40 mm cathode/anode gap, corresponding to field strength of 13.7 MV/m. Smaller gaps were studied to evaluate electrode performance at higher field strength with the best performing TiN-coated aluminum electrode reaching ~22.5 MV/m with field emission less than 100 pA. These results were comparable to those obtained from our best-performing electrodes manufactured from stainless steel, titanium alloy and niobium, as reported in references cited below. The TiN coating provided a very smooth surface and with mechanical properties of the coating (hardness and modulus) superior to those of stainless steel, titanium-alloy, and niobium electrodes. These features likely contributed to the improved high voltage performance of the TiN-coated aluminum electrodes.« less

  8. TiN coated aluminum electrodes for DC high voltage electron guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mamun, Md Abdullah A.; Elmustafa, Abdelmageed A., E-mail: aelmusta@odu.edu; Taus, Rhys

    Preparing electrodes made of metals like stainless steel, for use inside DC high voltage electron guns, is a labor-intensive and time-consuming process. In this paper, the authors report the exceptional high voltage performance of aluminum electrodes coated with hard titanium nitride (TiN). The aluminum electrodes were comparatively easy to manufacture and required only hours of mechanical polishing using silicon carbide paper, prior to coating with TiN by a commercial vendor. The high voltage performance of three TiN-coated aluminum electrodes, before and after gas conditioning with helium, was compared to that of bare aluminum electrodes, and electrodes manufactured from titanium alloymore » (Ti-6Al-4V). Following gas conditioning, each TiN-coated aluminum electrode reached −225 kV bias voltage while generating less than 100 pA of field emission (<10 pA) using a 40 mm cathode/anode gap, corresponding to field strength of 13.7 MV/m. Smaller gaps were studied to evaluate electrode performance at higher field strength with the best performing TiN-coated aluminum electrode reaching ∼22.5 MV/m with field emission less than 100 pA. These results were comparable to those obtained from our best-performing electrodes manufactured from stainless steel, titanium alloy and niobium, as reported in references cited below. The TiN coating provided a very smooth surface and with mechanical properties of the coating (hardness and modulus) superior to those of stainless steel, titanium-alloy, and niobium electrodes. These features likely contributed to the improved high voltage performance of the TiN-coated aluminum electrodes.« less

  9. TiN coated aluminum electrodes for DC high voltage electron guns

    DOE PAGES

    Mamun, Md Abdullah A.; Elmustafa, Abdelmageed A.; Taus, Rhys; ...

    2015-05-01

    Preparing electrodes made of metals like stainless steel, for use inside DC high voltage electron guns, is a labor-intensive and time-consuming process. In this paper, the authors report the exceptional high voltage performance of aluminum electrodes coated with hard titanium nitride (TiN). The aluminum electrodes were comparatively easy to manufacture and required only hours of mechanical polishing using silicon carbide paper, prior to coating with TiN by a commercial vendor. The high voltage performance of three TiN-coated aluminum electrodes, before and after gas conditioning with helium, was compared to that of bare aluminum electrodes, and electrodes manufactured from titanium alloymore » (Ti-6AI-4V). Following gas conditioning, each TiN-coated aluminum electrode reached -225 kV bias voltage while generating less than 100 pA of field emission (<10 pA) using a 40 mm cathode/anode gap, corresponding to field strength of 13.7 MV/m. Smaller gaps were studied to evaluate electrode performance at higher field strength with the best performing TiN-coated aluminum electrode reaching ~22.5 MV/m with field emission less than 100 pA. These results were comparable to those obtained from our best-performing electrodes manufactured from stainless steel, titanium alloy and niobium, as reported in references cited below. The TiN coating provided a very smooth surface and with mechanical properties of the coating (hardness and modulus) superior to those of stainless steel, titanium-alloy, and niobium electrodes. These features likely contributed to the improved high voltage performance of the TiN-coated aluminum electrodes.« less

  10. Gun buyback programs: a venue to eliminate unwanted guns in the community.

    PubMed

    Violano, Pina; Driscoll, Cassandra; Chaudhary, Neil K; Schuster, Kevin M; Davis, Kimberly A; Borer, Esther; Winters, Jane K; Hirsh, Michael P

    2014-09-01

    The United States has a high rate of death due to firearms, and gun buyback programs may mitigate these high death rates. Understanding the demographics, motivation, and geographic region of participants may improve program efficacy. Three Injury Free Coalition for Kids gun buyback programs, in collaboration with the local police, were studied: Phoenix, Arizona; Worcester, Massachusetts; and New Haven, Connecticut. Participants were defined as those who relinquished a firearm. A self-administered, anonymous, paper survey elicited information from participants regarding demographic data, formal training on the use of the firearm, how the firearm was acquired, potential child access, knowledge of others injured by a firearm, whether the firearm was stored unlocked, factors motivating the surrender of the firearm, and other factors. Survey results were entered into a composite database and analyzed for differences in location, race, sex, and other factors. Participants (n = 301) were predominantly male (73.5%), white (80.9%), and older than 55 years (59.0%). They lived an average of 19.0 miles from the event by zip codes and had an average median household income of $65,731. More than half (54.5%) did not purchase the firearm, acquiring it through inheritance, gift, or random find. Most (74.8%) had previous firearms training and were relinquishing for safety reasons (68.3%). Those relinquishing firearms for safety reasons were less likely to have purchased the firearm (odds ratio [OR], 2.46, p <0.05), less likely to have any formal training (OR, 5.92; p < 0.01), and less likely to keep the firearm locked (OR, 3.50; p < 0.01). Women were less likely to have purchased the firearm (OR, 0.50; p < 0.05). Fifty-three percent of those turning in firearms reported having at least one more firearm at home; designated themselves to be white, compared with all other groups combined (OR, 2.55; p < 0.05); more likely to report locking the firearm (OR, 0.11; p < 0.001); more

  11. Physicians Asking Patients About Guns: Promoting Patient Safety, Respecting Patient Rights.

    PubMed

    Parent, Brendan

    2016-10-01

    Recent debate on whether physicians should discuss gun ownership with their patients has centered on determining whether gun injuries are an issue of health or safety, and on protecting patient privacy. Yet, physicians' duties span personal health, public health, and safety spheres, and they often must address private patient matters. To prioritize gun safety and reduce gun injuries, the primary policy-driving question should be: will physician counseling on gun ownership effectively reduce gun-related injuries without interfering with the physician's other treatment obligations or compromising the physician-patient relationship? Existing data on physician-initiated conversations with patients about guns support a positive prevention effect. However, it is critical that physician-initiated discussions of safe gun practices are not motivated by, nor convey, disapproval of gun ownership. To be ethical, respectful, and efficient, the conversation should be standard between primary care providers and all of their patients (not limited to patient subsets); questions and education should be limited to topics of gun-ownership risks and storage practices; and the conversation must be framed without bias against gun ownership.

  12. Development program on a cold cathode electron gun

    NASA Technical Reports Server (NTRS)

    Spindt, C. A.; Holland, C. E.

    1985-01-01

    During this phase of the cathode development program, SRI improved the multiple electron beam exposure system used to print hole patterns for the cathode arrays, studied anisotropic etch processes, conducted cathode investigations using an emission microscope, reviewed possible alternate materials for cathode fabrication, studied cathode storage techniques, conducted high power operation experiments, and demonstrated high-current-density operation with small arrays of tips.

  13. Should gun safety be taught in schools? Perspectives of teachers.

    PubMed

    Obeng, Cecilia

    2010-08-01

    Gun-related injuries and deaths among children occur at disproportionately high rates in the United States. Children who live in homes with guns are the most likely victims. This study describes teachers' views on whether gun safety should be taught to children in the preschool and elementary years. A total of 150 survey questionnaires were distributed to public and private school teachers in preschools and elementary schools in 2 counties of a Midwestern state. In total, 62% of the 102 respondents indicated that they favored the teaching of gun safety, while 13% disapproved and 25% had no opinion. Overall, 28.4% of the respondents supported the teaching of gun safety in grades pre-K (pre-kindergarten) through first grade. About 54% indicated that police or trained military personnel should do the teaching of this subject in schools, while 6.9% suggested that teachers should do the teaching. With a majority of the teachers in favor of teaching gun safety in the schools, a larger study should be conducted that explores the introduction of gun safety into the curriculum in preschool through grade 6. Such a study should evaluate the efficacy of teaching gun safety as a measure to prevent gun violence and injuries involving guns.

  14. Evaluations of carbon nanotube field emitters for electron microscopy

    NASA Astrophysics Data System (ADS)

    Nakahara, Hitoshi; Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi

    2009-11-01

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I- V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6×109 A/m 2 sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  15. Actuated Recoil Absorbing Mounting System for use with an Underwater Gun

    DTIC Science & Technology

    1998-03-31

    fire supercavitating bullets, requires that 20 the new projectile launchers be tested. The firing of projectile 21 launchers involving a high...of projectile launcher 12 includes an underwater gun 15 that fires supercavitating bullets underwater and has a high 16 discharge energy. However

  16. Radiation Damage From Mono-energetic Electrons Up to 200 keV On Biological Systems

    NASA Astrophysics Data System (ADS)

    Prilepskiy, Yuriy

    2006-03-01

    The electron gun of the CEBAF machine at Jefferson lab (Newport News, VA) is capable of delivering electrons with energies up to 200 keV with a resolution of about 10-5. This 1.5 GHz beam permits to generate cellular radiation damage within minutes. We have performed irradiation of cancer cells with different energies and different currents to investigate their biological responses. This study will permit to address the physical processes involved in the RBE and LET at a level that supersedes current data listed in the literature by orders of magnitude. We will discuss the experimental setup and results of the first stage of data collected with this novel system. This research is part of a global program to provide detailed information for the understanding of radiation based cancer treatments.

  17. Design of a high-bunch-charge 112-MHz superconducting RF photoemission electron source

    DOE PAGES

    Xin, T.; Brutus, J. C.; Belomestnykh, Sergey A.; ...

    2016-09-01

    High-bunch-charge photoemission electron-sources operating in a continuous wave (CW) mode are required for many advanced applications of particle accelerators, such as electron coolers for hadron beams, electron-ion colliders, and free-electron lasers (FELs). Superconducting RF (SRF) has several advantages over other electron-gun technologies in CW mode as it offers higher acceleration rate and potentially can generate higher bunch charges and average beam currents. A 112 MHz SRF electron photoinjector (gun) was developed at Brookhaven National Laboratory (BNL) to produce high-brightness and high-bunch-charge bunches for the Coherent electron Cooling Proof-of-Principle (CeC PoP) experiment. Lastly, the gun utilizes a quarter-wave resonator (QWR) geometrymore » for assuring beam dynamics, and uses high quantum efficiency (QE) multi-alkali photocathodes for generating electrons.« less

  18. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing techniquemore » commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.« less

  19. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    DOE PAGES

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; ...

    2017-09-11

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing techniquemore » commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.« less

  20. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    NASA Astrophysics Data System (ADS)

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; Wang, Y.; Poelker, M.

    2017-09-01

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (˜11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.

  1. Experiments and Demonstrations with Soldering Guns.

    ERIC Educational Resources Information Center

    Henry, Dennis C.; Danielson, Sarah A.

    1993-01-01

    Discusses the essential electrical characteristics of a particular model of soldering gun. Presents four classroom demonstrations that utilize the soldering gun to test the following geometrics of wire loops as electromagnets: (1) the original tip; (2) a single circular loop; (3) a Helmholtz coil; and (4) the solenoid. (MDH)

  2. Utility of indices of gun availability in the community

    PubMed Central

    Shenassa, Edmond D; Daskalakis, Constantine; Buka, Stephen L

    2006-01-01

    Objective To estimate the degree to which the proportion of homicides and suicides committed with a gun is associated with reported availability of firearms across Chicago neighbourhoods. Methods Data were collected as part of the Project on Human Development in Chicago Neighborhoods (PHDCN), a combined neighbourhood and individual level study of the city of Chicago. The study used data from 837 PHDCN participants between the ages of 17 and 22, residing in 170 different neighbourhoods. Gun availability was measured via participant reports on whether they had carried a gun and whether they perceived gun access to be easy in their community. Data on suicides and homicides were obtained from the Chicago Department of Health. Results A 10% change in the proportion of homicides committed by a gun in a neighbourhood was associated with a 20% increase in both the odds of reported gun access and reported gun carrying (p = 0.002 and 0.048, respectively). The proportion of firearm related suicides was not associated with either of those self reported measures. Conclusions The proportion of firearm related homicides, but not the proportion of firearm related suicides, is a useful predictor of gun availability across small areas such as neighbourhoods. PMID:16401610

  3. Strong gun laws are not enough: the need for improved enforcement of secondhand gun transfer laws in Massachusetts.

    PubMed

    Braga, Anthony A; Hureau, David M

    2015-10-01

    Research suggests that an overwhelming majority of crime guns were transferred by private sellers before recovery by law enforcement. Unfortunately, most states do not regulate these transactions. This study examines whether analyses of state-level private transfer data could be used to develop interventions to reduce the supply of handguns to violent criminals. Traced Boston crime handguns first sold at Massachusetts license dealers were matched to state secondhand gun transfer data. Logistic regression and descriptive statistics were used to analyze the characteristics of recovered crime guns and in-state primary and secondary market transaction patterns. For crime handguns with records of secondary market transactions in Massachusetts, many rapidly move from private transfer to recovery by the police. Unfortunately, important transaction data on the in-state sources of nearly 63% of recovered handguns were not readily available to law enforcement agencies. Data on private transfers of guns could be used to prevent violent injuries by reducing criminal access. However, the passage of strong private transfer gun laws needs to be accompanied by investments in the vigorous enforcement of reporting requirements. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Rail damage in a solid-armature rail gun. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brassard, T.; Homan, C.G.

    1987-12-01

    Plasma-arc-drive rail guns operate by forming a high-temperature plasma behind the projectile using a thin metal fuze. These systems achieve the highest projectile velocities (about 12 km /sec), since the driving force includes a substantial plasma pressure as well as the electromagnetic or Lorentz force. Unfortunately, severe rail damage occurs primarily from the intense temperatures generated by the plasma arc and the wiping motion of the armature itself. The solid-armature gun replaces the plasma armature with a conducting metal armature. Since the plasma arcing is reduced or eliminated, the projectiles are accelerated mainly by the Lorentz force. Thus, solid armaturemore » rail guns operate at lower projectile velocities. The important tradeoff is that there is a substantial reduction in rail damage for metal armature projectiles. The elimination of the plasma force limits projectile velocities in the metal-armature rail guns. A more-subtle limit is the speed at which the commutation process can take place. Although the latter limit is still not well understood, experimental evidence indicates a commutation limit may occur near 6 to 7 km/sec. This velocity limit is still attractive for Army tactical missions for rail guns. The actual rail damage occurring with two types of metal armatures, wire brush contactors and monolithic metal contactors, and new developments in barrel technology, such as superconducting augmentation, are presented in this report.« less

  5. Gun Carrying by High School Students in Boston, MA: Does Overestimation of Peer Gun Carrying Matter?

    ERIC Educational Resources Information Center

    Hemenway, David; Vriniotis, Mary; Johnson, Renee M.; Miller, Matthew; Azrael, Deborah

    2011-01-01

    This paper investigates: (1) whether high school students overestimate gun carrying by their peers, and (2) whether those students who overestimate peer gun carrying are more likely to carry firearms. Data come from a randomly sampled survey conducted in 2008 of over 1700 high school students in Boston, MA. Over 5% of students reported carrying a…

  6. Not an 'iron pipeline', but many capillaries: regulating passive transactions in Los Angeles' secondary, illegal gun market.

    PubMed

    Chesnut, Kelsie Y; Barragan, Melissa; Gravel, Jason; Pifer, Natalie A; Reiter, Keramet; Sherman, Nicole; Tita, George E

    2017-08-01

    California has strict firearm-related laws and is exceptional in its regulation of firearms retailers. Though evidence suggests that these laws can reduce illegal access to guns, high levels of gun violence persist in Los Angeles (LA), California. This research seeks to describe the sources of guns accessed by active offenders in LA, California and reports offenders' motivations for obtaining guns. Los Angeles County Jail (LACJ) system (four facilities). Random sampling from a screened pool of eligible participants was used to conduct qualitative semistructured interviews with 140 incarcerated gun offenders in one of four (LACJ) facilities. Researchers collected data on firearm acquisition, experiences related to gun violence, and other topics, using a validated survey instrument. Grounded theory guided the collection and analysis of data. Respondents reported possession of 77 specific guns (79.2% handguns) collectively. Social networks facilitate access to illegal guns; the majority of interviewees acquired their illegal guns through a social connection (85.7%) versus an outside broker/unregulated retailer (8.5%). Most guns were obtained through illegal purchase (n=51) or gift (n=15). A quarter of gun purchasers report engaging in a passive transaction, or one initiated by another party. Passive gun buyers were motivated by concerns for personal safety and/or economic opportunity. In LA's illegal gun market, where existing social relationships facilitate access to guns across a diffuse network, individuals, influenced by both fear and economic opportunity, have frequent opportunities to illegally possess firearms through passive transactions. Gun policies should better target and minimise these transactions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Research on vibration characteristics of gun barrel based on contact model

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Zhou, Qizheng; Yue, Pengfei

    2017-04-01

    In order to study vibration characteristics of the gun barrel under the action of moving projectile, the gun barrel is simplified to cross sectional cantilever beam such as Euler. Considering contact conditions of inertia effect and projectile with the gun barrel, the equation of lateral vibration of the gun barrel is established under the projectile-gun coupling effect; the modal analysis method is used to give the analytic solutions of equation series. The effect of the motion parameters the projectile on the vibration of gun barrel is discussed, and characteristics of vibration of gun barrel are further studied under two conditions of repeating and projectile with mass eccentricity. The research results show that reasonable control of the acceleration of the projectile in the gun bore, and reduction of projectile mass eccentricity can help reduce the muzzle vibration at the gun firing. The research results can provide reference for overall design of the gun, and the modeling and analysis method used in the paper can be promoted for the solution of vibration of other related projects under the moving excitation.

  8. Ultrafast electron microscopy in materials science, biology, and chemistry

    NASA Astrophysics Data System (ADS)

    King, Wayne E.; Campbell, Geoffrey H.; Frank, Alan; Reed, Bryan; Schmerge, John F.; Siwick, Bradley J.; Stuart, Brent C.; Weber, Peter M.

    2005-06-01

    The use of pump-probe experiments to study complex transient events has been an area of significant interest in materials science, biology, and chemistry. While the emphasis has been on laser pump with laser probe and laser pump with x-ray probe experiments, there is a significant and growing interest in using electrons as probes. Early experiments used electrons for gas-phase diffraction of photostimulated chemical reactions. More recently, scientists are beginning to explore phenomena in the solid state such as phase transformations, twinning, solid-state chemical reactions, radiation damage, and shock propagation. This review focuses on the emerging area of ultrafast electron microscopy (UEM), which comprises ultrafast electron diffraction (UED) and dynamic transmission electron microscopy (DTEM). The topics that are treated include the following: (1) The physics of electrons as an ultrafast probe. This encompasses the propagation dynamics of the electrons (space-charge effect, Child's law, Boersch effect) and extends to relativistic effects. (2) The anatomy of UED and DTEM instruments. This includes discussions of the photoactivated electron gun (also known as photogun or photoelectron gun) at conventional energies (60-200 keV) and extends to MeV beams generated by rf guns. Another critical aspect of the systems is the electron detector. Charge-coupled device cameras and microchannel-plate-based cameras are compared and contrasted. The effect of various physical phenomena on detective quantum efficiency is discussed. (3) Practical aspects of operation. This includes determination of time zero, measurement of pulse-length, and strategies for pulse compression. (4) Current and potential applications in materials science, biology, and chemistry. UEM has the potential to make a significant impact in future science and technology. Understanding of reaction pathways of complex transient phenomena in materials science, biology, and chemistry will provide fundamental

  9. Construction of a 1 MeV Electron Accelerator for High Precision Beta Decay Studies

    NASA Astrophysics Data System (ADS)

    Longfellow, Brenden

    2014-09-01

    Beta decay energy calibration for detectors is typically established using conversion sources. However, the calibration points from conversion sources are not evenly distributed over the beta energy spectrum and the foil backing of the conversion sources produces perturbations in the calibration spectrum. To improve this, an external, tunable electron beam coupled by a magnetic field can be used to calibrate the detector. The 1 MeV electron accelerator in development at Triangle Universities Nuclear Laboratory (TUNL) utilizes a pelletron charging system. The electron gun shoots 104 electrons per second with an energy range of 50 keV to 1 MeV and is pulsed at a 10 kHz rate with a few ns width. The magnetic field in the spectrometer is 1 T and guiding fields of 0.01 to 0.05 T for the electron gun are used to produce a range of pitch angles. This accelerator can be used to calibrate detectors evenly over its energy range and determine the detector response over a range of pitch angles. Beta decay energy calibration for detectors is typically established using conversion sources. However, the calibration points from conversion sources are not evenly distributed over the beta energy spectrum and the foil backing of the conversion sources produces perturbations in the calibration spectrum. To improve this, an external, tunable electron beam coupled by a magnetic field can be used to calibrate the detector. The 1 MeV electron accelerator in development at Triangle Universities Nuclear Laboratory (TUNL) utilizes a pelletron charging system. The electron gun shoots 104 electrons per second with an energy range of 50 keV to 1 MeV and is pulsed at a 10 kHz rate with a few ns width. The magnetic field in the spectrometer is 1 T and guiding fields of 0.01 to 0.05 T for the electron gun are used to produce a range of pitch angles. This accelerator can be used to calibrate detectors evenly over its energy range and determine the detector response over a range of pitch angles

  10. The 3"/50 Gun. NAVPERS 10110.

    ERIC Educational Resources Information Center

    Bureau of Naval Personnel, Washington, DC.

    The document has been designed to provide enlisted men assigned to the 3"/50 gun with a self-study, on-the-job-training source for shipboard use. The material covered includes general description and operation, functions of various components, disassembly and reassembly, maintenance, and operational casualties of the 3"/50 gun. Detailed…

  11. Design of a LaB 6 gun using EGN2 and INTMAG

    NASA Astrophysics Data System (ADS)

    Becker, R.; Herrmannsfeldt, W. B.

    1990-12-01

    In order to launch a high-density electron beam to be focused in the 5 T superconducting solenoid of the Frankfurt EBIS [R. Becker et al., Nucl. Instr. and Meth. B24 (1987) 838], an electron gun has been designed, with a 0.5 mm diameter LaB 6 cathode (FEI Comp., Beaverton, USA) in a 70 mm diameter electrode geometry. The emitting surface is placed in the axial fringing field of the solenoid, modified by an axial shielding disk and a bucking coil, to provide either immersed flow or Brillouin flow conditions for the focused beam. Since the cathode diameter is small as compared to the electrodes, a new feature of EGN2 [W.B. Herrmannsfeldt, SLAC-331 (1988)] had to be used in order to have a sufficient number of meshes along the emitting surface. By starting a field line in the large geometry, a curved Neumann boundary is found for a subdivided part of the gun, which represents the influence of the larger part. EGN2 writes the coordinates of this field line on a file, which can be used by POLYGON [R. Becker, Nucl. Instr. and Meth. B42 (1989) 162] (a boundary setup program for EGN2) to define a curved Neumann boundary. By this procedure, it becomes possible to get a reliable simulation of the emission properties of a small cathode in large gun electrodes. The magnetostatic field calculations have been performed with INTMAG [R. Becker, Nucl. Instr. and Meth. B42 (1989) 303], which is a new program of the boundary element method type. Due to the integration calculus, the results do not need smoothing or "Maxwellisation" for the use in EGN2, where the off-axis fields are evaluated by radial expansion. INTMAG provides an output file, which is suitably formatted to be read in by EGN2. The gun design is based on space-charge-limited emission, but no Pierce-type electrode has been provided in the vicinity of the cathode; instead a Wehnelt electrode on negative bias with respect to the cathode is used to create the correct Pierce-type equipotential in free space, ending on the

  12. Accidental Bolt Gun Injury to Femur - A Case Report.

    PubMed

    Kattimani, Ravi Prasad; Shetty, Sanath; Mirza, Humayun

    2016-01-01

    Bolt gun or slaughterer's guns are used in meat industry for "humane killing" of animals. Injuries caused by bolt gun are rare, reported exclusively from central European countries. We report a case of 28 year old male, who accidentally shot himself with a bolt gun to his right thigh. A 28 years old male presented to our Accident and Emergency department after accidental injury to his right thigh with bolt gun. He had an entry wound measuring 2 cm in length and 1 cm in breadth over anterior aspect of lower one third of thigh at lower and sustained Grade II compound fracture of right femur shaft at distal one third. The wound was treated with multiple debridements, negative pressure wound therapy and intravenous antibiotics based on culture and sensitivity. Bolt gun or slaughterer's guns are weapons used in meat industry for slaughtering animals. Wounds inflicted by bolt guns have specific morphological feature, distinctive from wounds made by other kinds of hand firearms. Most of the time wound will be infected at presentation. Lesions caused by these weapons are likely to have a more serious character than is to be expected from the size of the entrance wound. The mainstay of treatment is liberal wound exploration, multiple debridement's and intra venous antibiotics based on culture reports to treat infection and prevent morbidity.

  13. Optimization of a two stage light gas gun. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Rynearson, R. J.; Rand, J. L.

    1972-01-01

    Performance characteristics of the Texas A&M University light gas gun are presented along with a review of basic gun theory and popular prediction methods. A computer routine based on the simple isentropic compression method is discussed. Results from over 60 test shots are given which demonstrate an increase in gun muzzle velocity from 9.100 ft/sec. to 19,000 ft/sec. The data gathered indicated the Texas A&M light gas gun more closely resembles an isentropic compression gun rather than a shock compression gun.

  14. Implications of Gun Launch to Space for Nanosatellite Architectures

    NASA Technical Reports Server (NTRS)

    Palmer, Miles R.

    1995-01-01

    Engineering and economic scaling factors for gun launch to space (GLTS) systems are compared to conventional rocket launch systems. It is argued that GLTS might reduce the cost of small satellite development and launch in the mid to far term, thereby inducing a shift away from large centralized geosynchronous communications satellites to small proliferated low earth orbit systems.

  15. The research progress of perforating gun inner wall blind hole machining method

    NASA Astrophysics Data System (ADS)

    Wang, Zhe; Shen, Hongbing

    2018-04-01

    Blind hole processing method has been a concerned technical problem in oil, electronics, aviation and other fields. This paper introduces different methods for blind hole machining, focus on machining method for perforating gun inner wall blind hole processing. Besides, the advantages and disadvantages of different methods are also discussed, and the development trend of blind hole processing were introduced significantly.

  16. Characteristics of a gun exchange program, and an assessment of potential benefits

    PubMed Central

    Romero, M.; Wintemute, G.; Vernick, J.

    1998-01-01

    Objectives—To describe a gun exchange program and assess potential benefits for participants and host communities. Methods—Mail survey of participants in a Sacramento, California gun exchange program, August 1993; the response rate was 79%. Comparative data were obtained from nationwide polls of gun owners. Results—Most (62%) respondents were men; 40% were more than 55 years old; none was less than 25. Concern that children might find and use the gun was the most frequently cited reason for participating (46% of respondents). Of 141 firearms exchanged, 72% were handguns; 23% of respondents indicated that the guns they turned in were not in working order. Of respondents who owned a gun at the time of the program (rather than those who owned no guns and turned in a gun owned by someone else), 41% owned no guns after participating; the prevalence of handgun ownership declined from 79% to 32%. Those who continued to own guns were as likely as gun owners nationwide to keep a gun loaded in the house (odds ratio (OR) 0.9, 95% confidence interval (CI) 0.4 to 1.7) or to carry a gun with them (OR 1.5, 95% CI 0.6 to 3.8). Conclusions—Gun exchange programs may reduce risk for firearm violence among some participants, but a number of factors limit their overall benefits to host communities. PMID:9788092

  17. A titanium hydride gun for plasma injection into the T2-reversed field pinch device

    NASA Astrophysics Data System (ADS)

    Voronin, A. V.; Hellblom, K. G.

    1999-02-01

    A study of a plasma gun (modified Bostic type) with titanium hydride electrodes has been carried out. The total number of released hydrogen atoms was in the range 1016-1018 and the maximum plasma flow velocity was 2.5×105 m s-1. The ion density near the gun edge reached 1.8×1020 m-3 and the electron temperature was around 40 eV as estimated from probe measurements. No species other than hydrogen or titanium were seen in the plasma line radiation. The plasma injector was successfully used for gas pre-ionization in the Extrap T2 reversed-field pinch device (ohmic heating toroidal experiment (OHTE)).

  18. Handgun waiting periods reduce gun deaths

    PubMed Central

    Luca, Michael; Malhotra, Deepak

    2017-01-01

    Handgun waiting periods are laws that impose a delay between the initiation of a purchase and final acquisition of a firearm. We show that waiting periods, which create a “cooling off” period among buyers, significantly reduce the incidence of gun violence. We estimate the impact of waiting periods on gun deaths, exploiting all changes to state-level policies in the Unites States since 1970. We find that waiting periods reduce gun homicides by roughly 17%. We provide further support for the causal impact of waiting periods on homicides by exploiting a natural experiment resulting from a federal law in 1994 that imposed a temporary waiting period on a subset of states. PMID:29078268

  19. High voltage studies of inverted-geometry ceramic insulators for a 350 kV DC polarized electron gun

    DOE PAGES

    Hernandez-Garcia, C.; Poelker, M.; Hansknecht, J.

    2016-02-01

    Jefferson Lab is constructing a 350 kV direct current high voltage photoemission gun employing a compact inverted-geometry insulator. This photogun will produce polarized electron beams at an injector test facility intended for low energy nuclear physics experiments, and to assist the development of new technology for the Continuous Electron Beam Accelerator Facility. A photogun operating at 350kV bias voltage reduces the complexity of the injector design, by eliminating the need for a graded-beta radio frequency “capture” section employed to boost lower voltage beams to relativistic speed. However, reliable photogun operation at 350 kV necessitates solving serious high voltage problems relatedmore » to breakdown and field emission. This study focuses on developing effective methods to avoid breakdown at the interface between the insulator and the commercial high voltage cable that connects the photogun to the high voltage power supply. Three types of inverted insulators were tested, in combination with two electrode configurations. Our results indicate that tailoring the conductivity of the insulator material, and/or adding a cathode triple-junction screening electrode, effectively serves to increase the hold-off voltage from 300kV to more than 375kV. In conclusion, electrostatic field maps suggest these configurations serve to produce a more uniform potential gradient across the insulator.« less

  20. High voltage studies of inverted-geometry ceramic insulators for a 350 kV DC polarized electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez-Garcia, C.; Poelker, M.; Hansknecht, J.

    Jefferson Lab is constructing a 350 kV direct current high voltage photoemission gun employing a compact inverted-geometry insulator. This photogun will produce polarized electron beams at an injector test facility intended for low energy nuclear physics experiments, and to assist the development of new technology for the Continuous Electron Beam Accelerator Facility. A photogun operating at 350kV bias voltage reduces the complexity of the injector design, by eliminating the need for a graded-beta radio frequency “capture” section employed to boost lower voltage beams to relativistic speed. However, reliable photogun operation at 350 kV necessitates solving serious high voltage problems relatedmore » to breakdown and field emission. This study focuses on developing effective methods to avoid breakdown at the interface between the insulator and the commercial high voltage cable that connects the photogun to the high voltage power supply. Three types of inverted insulators were tested, in combination with two electrode configurations. Our results indicate that tailoring the conductivity of the insulator material, and/or adding a cathode triple-junction screening electrode, effectively serves to increase the hold-off voltage from 300kV to more than 375kV. In conclusion, electrostatic field maps suggest these configurations serve to produce a more uniform potential gradient across the insulator.« less

  1. An ultrastructural study of sporidium formation during infection of a rhabditid nematode by large gun cells of Haptoglossa heteromorpha.

    PubMed

    Glockling, S L; Beakes, G W

    2000-10-01

    Recently fired gun cells of Haptoglossa heteromorpha, an aplanosporic nematode parasite, were examined ultrastructurally. The everted tubes of the fired cells had penetrated the cuticle of a nematode, and infective sporidia were developing inside the host body. The nematode cuticle was penetrated by the narrow, walled part of the tube below the needle chamber. The lower unwalled part of the tube tail formed the sporidium. The developing sporidium had a multilayered fibrous outer coating and the plasma membrane was separated from the wall in places. Sporidia contained biphasic membrane-bound vesicles that had been generated by the Golgi dictyosome during gun cell development. Immediately following gun cell firing, the nuclear envelope of the sporidium nucleus was not apparent, and the sporidium nucleus contained clusters of electron-dense particles concentrated in the nucleolar region. We compare the structures and organelles found in the mature gun cell with those in the fired cell and attempt to identify the membranous layers around the sporidium. Copyright 2000 Academic Press.

  2. Youth Homicide and Guns. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Young Americans are killed with guns at rates far higher than young people in other countries and than older Americans, with young, urban African-American males being most at risk. This fact sheet presents data on gun-related homicides among teenagers in the United States. The high rate of youth homicide in the United States is unique in the…

  3. Law enforcement officers' opinions about gun locks: anchors on life jackets?

    PubMed Central

    Coyne-Beasley, T; Johnson, R

    2001-01-01

    Objectives—One way law enforcement officers support firearm safety is by promoting the use of gun locks. This investigation examined law enforcement officers' willingness to use gun locks on their own guns, as well as their opinions regarding gun locks in general. Setting—Law enforcement officers from an urban agency in the southern region of the United States. Methods—Free keyed cable gun locks were distributed to all law enforcement officers in one agency who wanted one, and then an anonymous questionnaire survey was conducted about their subsequent use of, and attitudes toward, these devices. Results—About half of the 207 officers collected gun locks (n=103). Nearly three quarters (73%) completed and returned the questionnaire. Two thirds reported that they were not using the gun lock they collected (65%), and over half disagreed that gun lock use should be required (56%). Very few cited any actual or potential technical problems with the device. An important reason given for non-use of gun locks related to being able to access the weapon quickly in case of an emergency. Conclusions—The findings highlight the need for further investigation into law enforcement officers' attitudes toward gun locks, the degree to which their attitudes affect their firearm safety counseling, and the need to develop a gun safety device that can be disengaged quickly. PMID:11565984

  4. ONEGUN: an interior ballistics code for closed breech guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reis, G.E.

    1982-07-01

    This program computes the gun and projectile motion and the gas thermodynamic properties (the internal ballistics) of a closed breech gun. Heat losses and friction losses are taken into account. A dual grain charge can be used. The inputs required are the usual propellant characteristics (density, impetus, gamma, burn rate coefficient and exponent, grain geometry, covolume and isochoric flame temperature). The gun characteristics (chamber volume and length, rifle twist rate, bore diameter, gun weight and start pressure) and the projectile characteristics (projectile weight, radius of gyration and start pressure). The output consists of the motion (displacement, velocity, and acceleration) ofmore » both the projectile and the recoiling gun and the gas pressures and temperature, all as a function of time.« less

  5. Gun utopias? Firearm access and ownership in Israel and Switzerland

    PubMed Central

    Rosenbaum, Janet

    2011-01-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim that mass-casualty events are mitigated and deterred with three policies: (1) permissive gun laws, (2) widespread gun ownership, (3) encouragement of armed civilians who can intercept shooters, and cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source material. Swiss and Israeli laws limit firearm ownership and require permit renewal 14 times annually. ICVS analysis finds that the US has more firearms per capita and per household than either country. Switzerland and Israel curtail off-duty soldiers firearm access to prevent firearm deaths. Suicide among soldiers decreased by 40% after the Israeli armys 2006 reforms. Compared with the US, Switzerland and Israel have lower gun ownership and stricter gun laws, and their policies discourage personal gun ownership. PMID:22089893

  6. Gun utopias? Firearm access and ownership in Israel and Switzerland.

    PubMed

    Rosenbaum, Janet E

    2012-02-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim mass-casualty events are mitigated and deterred with three policies: (a) permissive gun laws, (b) widespread gun ownership, (c) and encouragement of armed civilians who can intercept shooters. They cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source material. Swiss and Israeli laws limit firearm ownership and require permit renewal one to four times annually. ICVS analysis finds the United States has more firearms per capita and per household than either country. Switzerland and Israel curtail off-duty soldiers' firearm access to prevent firearm deaths. Suicide among soldiers decreased by 40 per cent after the Israeli army's 2006 reforms. Compared with the United States, Switzerland and Israel have lower gun ownership and stricter gun laws, and their policies discourage personal gun ownership.

  7. Measurements of line-averaged electron density of pulsed plasmas using a He-Ne laser interferometer in a magnetized coaxial plasma gun device

    NASA Astrophysics Data System (ADS)

    Iwamoto, D.; Sakuma, I.; Kitagawa, Y.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    In next step of fusion devices such as ITER, lifetime of plasma-facing materials (PFMs) is strongly affected by transient heat and particle loads during type I edge localized modes (ELMs) and disruption. To clarify damage characteristics of the PFMs, transient heat and particle loads have been simulated by using a plasma gun device. We have performed simulation experiments by using a magnetized coaxial plasma gun (MCPG) device at University of Hyogo. The line-averaged electron density measured by a He-Ne interferometer is 2x10^21 m-3 in a drift tube. The plasma velocity measured by a time of flight technique and ion Doppler spectrometer was 70 km/s, corresponding to the ion energy of 100 eV for helium. Thus, the ion flux density is 1.4x10^26 m-2s-1. On the other hand, the MCPG is connected to a target chamber for material irradiation experiments. It is important to measure plasma parameters in front of target materials in the target chamber. In particular, a vapor cloud layer in front of the target material produced by the pulsed plasma irradiation has to be characterized in order to understand surface damage of PFMs under ELM-like plasma bombardment. In the conference, preliminary results of application of the He-Ne laser interferometer for the above experiment will be shown.

  8. Spectrometer gun

    DOEpatents

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  9. Reducing Energy Degradation Due to Back-bombardment Effect with Modulated RF Input in S-band Thermionic RF Gun

    NASA Astrophysics Data System (ADS)

    Kii, Toshiteru; Nakai, Yoko; Fukui, Toshio; Zen, Heishun; Kusukame, Kohichi; Okawachi, Norihito; Nakano, Masatsugu; Masuda, Kai; Ohgaki, Hideaki; Yoshikawa, Kiyoshi; Yamazaki, Tetsuo

    2007-01-01

    Energy degradation due to back-bombardment effect is quite serious to produce high-brightness electron beam with long macro-pulse with thermionic rf gun. To avoid the back-bombardment problem, a laser photo cathode is used at many FEL facilities, but usually it costs high and not easy to operate. Thus we have studied long pulse operation of the rf gun with thermionic cathode, which is inexpensive and easy to operate compared to the photocathode rf gun. In this work, to reduce the energy degradation, we controlled input rf power amplitude by controlling pulse forming network of the power modulator for klystron. We have successfully increased the pulse duration up to 4 μs by increasing the rf power from 7.8 MW to 8.5 MW during the macro pulse.

  10. Specifying the role of exposure to violence and violent behavior on initiation of gun carrying: a longitudinal test of three models of youth gun carrying.

    PubMed

    Spano, Richard; Pridemore, William Alex; Bolland, John

    2012-01-01

    Two waves of longitudinal data from 1,049 African American youth living in extreme poverty are used to examine the impact of exposure to violence (Time 1) and violent behavior (Time 1) on first time gun carrying (Time 2). Multivariate logistic regression results indicate that (a) violent behavior (Time 1) increased the likelihood of initiation of gun carrying (Time 2) by 76% after controlling for exposure to violence at Time 1, which is consistent with the stepping stone model of youth gun carrying, and (b) youth who were both exposed to violence at Time 1 and engaged in violent behavior at Time 1 were more than 2.5 times more likely to initiate gun carrying at Time 2 compared to youth who had neither of these characteristics, which supports the cumulative risk model of youth gun carrying. The authors discuss the implications of these findings in clarifying the role of violence in the community on youth gun carrying and the primary prevention of youth gun violence.

  11. Mass Shootings, Mental Illness, and Gun Control.

    PubMed

    Philpott-Jones, Sean

    2018-03-01

    In the wake of the Stoneman Douglas School shooting, Republican and Democratic leaders-like the American electorate they represent-remain sharply divided in their responses to gun violence. They are united in their condemnation of these mass shootings, but they disagree about whether stricter or looser gun control laws are the answer. Those on the right side of the political aisle suggest that the issue is one of mental illness rather than gun control. Conversely, those who are more liberal or progressive in their political learnings are quick to condemn attempts to reframe the issue of mass shootings as a mental health problem. Both sides are wrong. Mass shootings are indeed partially a mental health problem, albeit one poorly addressed by our current laws and policies. But the solution to mass shootings also needs to consider strategies that may reduce gun violence in general. © 2018 The Hastings Center.

  12. Spectrometer gun

    DOEpatents

    Waechter, D.A.; Wolf, M.A.; Umbarger, C.J.

    1981-11-03

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun is described that includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  13. Handgun waiting periods reduce gun deaths.

    PubMed

    Luca, Michael; Malhotra, Deepak; Poliquin, Christopher

    2017-11-14

    Handgun waiting periods are laws that impose a delay between the initiation of a purchase and final acquisition of a firearm. We show that waiting periods, which create a "cooling off" period among buyers, significantly reduce the incidence of gun violence. We estimate the impact of waiting periods on gun deaths, exploiting all changes to state-level policies in the Unites States since 1970. We find that waiting periods reduce gun homicides by roughly 17%. We provide further support for the causal impact of waiting periods on homicides by exploiting a natural experiment resulting from a federal law in 1994 that imposed a temporary waiting period on a subset of states. Copyright © 2017 the Author(s). Published by PNAS.

  14. Oregon's Gun Relief Program for Adjudicated Mentally Ill Persons: The Psychiatric Security Review Board.

    PubMed

    Britton, Juliet; Bloom, Joseph D

    2015-06-01

    This article describes the State of Oregon's implementation of two programs designed to comply with federal gun laws regarding reporting individuals who have received mental health adjudications in criminal and civil courts. One mandate requires that states submit names of adjudicated individuals to the National Instant Criminal Background Check System (NICS) while the second requires that the state establish a qualifying gun restoration program for those disqualified from gun ownership. In 2009, Oregon's Legislature developed an administrative approach to gun restoration and assigned the responsibility for conducting these hearing to the Oregon Psychiatric Security Review Board (PSRB). The PSRB is a state administrative board that has existed since 1977 and has been primarily focused on the supervision and treatment of adult and juvenile insanity acquittees. The gun restoration program began in 2010, but to date has only received three completed petitions requesting restoration of firearm rights. The article concludes with a discussion that surmises why very few of the Oregonians who are listed in NICS have submitted petitions for relief. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Computer simulation of electron flow in linear-beam microwave tubes

    NASA Astrophysics Data System (ADS)

    Kumar, Lalit

    1990-12-01

    The computer simulation of electron flow in linear-beam microwave tubes, such as a travelling-wave tube (TWT) and klystron, is used for designing and optimising the electron gun and collector and for analysing the large-signal beam-wave interaction phenomenon. Major aspects of simulation of electron flow in static and rf fields present in such tubes are discussed. Some advancements made in this respect and results obtained from computer programs developed by the research group at CEERI for a gridded electron gun, depressed collector, and large-signal analysis of TWT and klystron are presented.

  16. First beam commissioning at BNL ERL SRF Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, W.; Altinbas, Z.; Belomestnykh, S.

    The 704 MHz SRF gun successfully generated the first photoemission beam in November of 2014. The configurations of the test and the sub-systems are described.The latest results of SRF commissioning, including the cavity performance, cathode QE measurements, beam current/energy measurements, are presented in the paper.

  17. Influence of pellet seating on the external ballistic parameters of spring-piston air guns.

    PubMed

    Werner, Ronald; Schultz, Benno; Frank, Matthias

    2016-09-01

    In firearm examiners' and forensic specialists' casework as well as in air gun proof testing, reliable measurement of the weapon's muzzle velocity is indispensable. While there are standardized and generally accepted procedures for testing the performance of air guns, the method of seating the diabolo pellets deeper into the breech of break barrel spring-piston air guns has not found its way into standardized test procedures. The influence of pellet seating on the external ballistic parameters was investigated using ten different break barrel spring-piston air guns. Test shots were performed with the diabolo pellets seated 2 mm deeper into the breech using a pellet seater. The results were then compared to reference shots with conventionally loaded diabolo pellets. Projectile velocity was measured with a high-precision redundant ballistic speed measurement system. In eight out of ten weapons, the muzzle energy increased significantly when the pellet seater was used. The average increase in kinetic energy was 31 % (range 9-96 %). To conclude, seating the pellet even slightly deeper into the breech of spring-piston air guns might significantly alter the muzzle energy. Therefore, it is strongly recommended that this effect is taken into account when accurate and reliable measurements of air gun muzzle velocity are necessary.

  18. Performance of low-voltage STEM/TEM with delta corrector and cold field emission gun.

    PubMed

    Sasaki, Takeo; Sawada, Hidetaka; Hosokawa, Fumio; Kohno, Yuji; Tomita, Takeshi; Kaneyama, Toshikatsu; Kondo, Yukihito; Kimoto, Koji; Sato, Yuta; Suenaga, Kazu

    2010-08-01

    To reduce radiation damage caused by the electron beam and to obtain high-contrast images of specimens, we have developed a highly stabilized transmission electron microscope equipped with a cold field emission gun and spherical aberration correctors for image- and probe-forming systems, which operates at lower acceleration voltages than conventional transmission electron microscopes. A delta-type aberration corrector is designed to simultaneously compensate for third-order spherical aberration and fifth-order 6-fold astigmatism. Both were successfully compensated in both scanning transmission electron microscopy (STEM) and transmission electron microscopy (TEM) modes in the range 30-60 kV. The Fourier transforms of raw high-angle annular dark field (HAADF) images of a Si[110] sample revealed spots corresponding to lattice spacings of 111 and 96 pm at 30 and 60 kV, respectively, and those of raw TEM images of an amorphous Ge film with gold particles showed spots corresponding to spacings of 91 and 79 pm at 30 and 60 kV, respectively. Er@C(82)-doped single-walled carbon nanotubes, which are carbon-based samples, were successfully observed by HAADF-STEM imaging with an atomic-level resolution.

  19. Contoured-gap coaxial guns for imploding plasma liner experiments

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. D.; Case, A.; Brockington, S.; Cassibry, J. T.; Hsu, S. C.

    2014-10-01

    Arrays of supersonic, high momentum flux plasma jets can be used as standoff compression drivers for generating spherically imploding plasma liners for driving magneto-inertial fusion, hence the name plasma-jet-driven MIF (PJMIF). HyperV developed linear plasma jets for the Plasma Liner Experiment (PLX) at LANL where two guns were successfully tested. Further development at HyperV resulted in achieving the PLX goal of 8000 μg at 50 km/s. Prior work on contoured-gap coaxial guns demonstrated an approach to control the blowby instability and achieved substantial performance improvements. For future plasma liner experiments we propose to use contoured-gap coaxial guns with small Minirailgun injectors. We will describe such a gun for a 60-gun plasma liner experiment. Discussion topics will include impurity control, plasma jet symmetry and topology (esp. related to uniformity and compactness), velocity capability, and techniques planned for achieving gun efficiency of >50% using tailored impedance matched pulse forming networks. Mach2 and UAH SPH code simulations will be included. Work supported by US DOE DE-FG02-05ER54810.

  20. National attitudes concerning gun carrying in the United States

    PubMed Central

    Hemenway, D; Azrael, D; Miller, M

    2001-01-01

    Objectives—To determine public attitudes in the United States concerning gun carrying. Setting—In the past 15 years, many state legislatures have passed laws making it easier for United States citizens to carry concealed firearms, not only on the street but into various locations, including churches and government buildings. Methods—National random digit dial telephone surveys conducted in 1996 and 1999 asked questions concerning the public's feelings of safety as more people in their community carry firearms, and whether, in the language of the question, respondents believe "regular" citizens should be allowed to carry guns into public or government buildings. Results—Americans feel less safe rather than more safe as more people in their community begin to carry guns. By margins of at least nine to one, Americans do not believe that "regular" citizens should be allowed to bring their guns into restaurants, college campuses, sports stadiums, bars, hospitals, or government buildings. Conclusions—The public believes that increased gun carrying by others reduces rather than increases their safety. Overwhelmingly, the public believes that in many venues gun carrying should be prohibited. PMID:11770652