NASA Astrophysics Data System (ADS)
Alexander, Andrew William
Within the field of medical physics, Monte Carlo radiation transport simulations are considered to be the most accurate method for the determination of dose distributions in patients. The McGill Monte Carlo treatment planning system (MMCTP), provides a flexible software environment to integrate Monte Carlo simulations with current and new treatment modalities. A developing treatment modality called energy and intensity modulated electron radiotherapy (MERT) is a promising modality, which has the fundamental capabilities to enhance the dosimetry of superficial targets. An objective of this work is to advance the research and development of MERT with the end goal of clinical use. To this end, we present the MMCTP system with an integrated toolkit for MERT planning and delivery of MERT fields. Delivery is achieved using an automated "few leaf electron collimator" (FLEC) and a controller. Aside from the MERT planning toolkit, the MMCTP system required numerous add-ons to perform the complex task of large-scale autonomous Monte Carlo simulations. The first was a DICOM import filter, followed by the implementation of DOSXYZnrc as a dose calculation engine and by logic methods for submitting and updating the status of Monte Carlo simulations. Within this work we validated the MMCTP system with a head and neck Monte Carlo recalculation study performed by a medical dosimetrist. The impact of MMCTP lies in the fact that it allows for systematic and platform independent large-scale Monte Carlo dose calculations for different treatment sites and treatment modalities. In addition to the MERT planning tools, various optimization algorithms were created external to MMCTP. The algorithms produced MERT treatment plans based on dose volume constraints that employ Monte Carlo pre-generated patient-specific kernels. The Monte Carlo kernels are generated from patient-specific Monte Carlo dose distributions within MMCTP. The structure of the MERT planning toolkit software and optimization algorithms are demonstrated. We investigated the clinical significance of MERT on spinal irradiation, breast boost irradiation, and a head and neck sarcoma cancer site using several parameters to analyze the treatment plans. Finally, we investigated the idea of mixed beam photon and electron treatment planning. Photon optimization treatment planning tools were included within the MERT planning toolkit for the purpose of mixed beam optimization. In conclusion, this thesis work has resulted in the development of an advanced framework for photon and electron Monte Carlo treatment planning studies and the development of an inverse planning system for photon, electron or mixed beam radiotherapy (MBRT). The justification and validation of this work is found within the results of the planning studies, which have demonstrated dosimetric advantages to using MERT or MBRT in comparison to clinical treatment alternatives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eldib, A; Al-Azhar University Cairo; Jin, L
2014-06-01
Purpose: Modulated electron radiotherapy (MERT) has the potential to achieve better treatment outcome for shallow tumors such as those of breast and scalp. In a separate study with scalp lesions, MERT was compared to volumetric modulated arc therapy. Our results showed a reduction in the dose reaching the brain with MERT. However dose calculation accuracy and delivery efficiency challenges remain. Thus in the current study we proceed to add more cases to demonstrate MERT beneficial outcome and its delivery accuracy using an electron specific multileaf collimator (eMLC). Methods: We have used the MCBEAM code for treatment head simulation and formore » generating phase space files to be used as radiation source input for our Monte Carlo based treatment planning system (MC TPS). MCPLAN code is used for calculation of patient specific dose deposition coefficient and for final MERT plan dose calculation. An in-house developed optimization code is used for the optimization process. MERT plans were generated for real patients and head and neck phantom. Film was used for dosimetric verification. The film was cut following the contour of the curved phantom surface and then sealed with black masking tape. In the measurement, the sealed film packet was sandwiched between two adjacent slabs of the head and neck phantom. The measured 2D dose distribution was then compared with calculations. Results: The eMLC allows effective treatment of scalps with multi-lesions spreading around the patient head, which was usually difficult to plan or very time consuming with conventional applicators. MERT continues to show better reduction in the brain dose. The dosimetric measurements showed slight discrepancy, which was attributed to the film setup. Conclusion: MERT can improve treatment plan quality for patients with scalp cancers. Our in-house MC TPS is capable of performing treatment planning and accurate dose calculation for MERT using the eMLC.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Q.
In memory of the significant contribution of Dr. Jacques Ovadia to electron beam techniques, this session will review recent, advanced techniques which are reinvigorating the science of electron beam radiation therapy. Recent research efforts in improving both the applicability and quality of the electron beam therapy will be discussed, including modulated electron beam radiotherapy (MERT) and dynamic electron arc radiotherapy (DEAR). Learning Objectives: To learn about recent advances in electron beam therapy, including modulated electron beam therapy and dynamic electron arc therapy (DEAR). Put recent advances in the context of work that Dr. Ovadia pursued during his career in medicalmore » physics.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, L; Fan, J; Eldib, A
Purpose: Treating nose skin with an electron beam is of a substantial challenge due to uneven nose surfaces and tissue heterogeneity, and consequently could have a great uncertainty of dose accuracy on the target. This work explored the method using Monte Carlo (MC)-based energy and intensity modulated electron radiotherapy (MERT), which would be delivered with a photon MLC in a standard medical linac (Artiste). Methods: The traditional treatment on the nose skin involves the usage of a bolus, often with a single energy electron beam. This work avoided using the bolus, and utilized mixed energies of electron beams. An in-housemore » developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. A clinical case of the nose skin, which was previously treated with a single 9 MeV electron beam, was replanned with the MERT method. The resultant dose distributions were compared with the plan previously clinically used. The dose volume histogram of the MERT plan is calculated to examine the coverage of the planning target volume (PTV) and critical structure doses. Results: The target coverage and conformality in the MERT plan are improved as compared to the conventional plan. The MERT can provide more sufficient target coverage and less normal tissue dose underneath the nose skin. Conclusion: Compared to the conventional treatment technique, using MERT for the nose skin treatment has shown the dosimetric advantages in the PTV coverage and conformality. In addition, this technique eliminates the necessity of the cutout and bolus, which makes the treatment more efficient and accurate.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller, S; Joosten, A; Fix, MK
Purpose: To estimate the dosimetric potential of mixed beam radiotherapy (MBRT) by using a single process optimizing the shape and weight of photon and electron apertures simultaneously based on Monte Carlo beamlet dose distributions. Methods: A simulated annealing based direct aperture optimization capable to perform simultaneous optimization was developed to generate treatment plans for MERT, photon-IMRT and MBRT. Both photon and electron apertures are collimated with the photon-MLC and are delivered in a segmented manner. For dosimetric comparison and for investigating the dependency on the number of apertures, photon-IMRT, MERT and MBRT plans were generated for an academic case consistingmore » of a water phantom containing two shallow PTVs differing in the maximal depth of 5 and 7 cm, respectively and two OARs in distal and lateral direction to the PTVs. Results: For the superficial PTV, the dose homogeneity (V95%–V107%) and the mean dose (in percent of the prescribed dose) to the distal and the lateral OARs of the MBRT plan (94.9%, 16.9%, 17.8%) are superior or comparable to those for the MERT (74%, 18.4%, 15.4%) and the photon-IMRT plan (89.4%, 20.8%, 24.7%). For the enlarged PTV, the dosimetric superiority of MBRT compared to MERT and photon-IMRT is even more pronounced. Furthermore, an MBRT plan with 12 electron and 10 photon apertures lead to an objective function value 38% lower than that of a photon-IMRT plan with 40 apertures. Conclusion: The results of simultaneous optimization for MBRT are promising with regards to further OAR sparing and improved dose coverage to the PTV compared to photon-IMRT and MERT. Especially superficial targets with deeper subparts (>5 cm) could substantially benefit. Moreover, MBRT seems to be a possible solution of two downsides of photon-IMRT, namely the extended low dose bath and the requirement of numerous apertures. This work was supported by Varian Medical Systems. This work was supported by Varian Medical Systems.« less
NASA Astrophysics Data System (ADS)
Salguero, Francisco Javier; Arráns, Rafael; Atriana Palma, Bianey; Leal, Antonio
2010-03-01
The purpose of this paper is to assess the feasibility of delivering intensity- and energy-modulated electron radiation treatment (MERT) by a photon multileaf collimator (xMLC) and to evaluate the improvements obtained in shallow head and neck (HN) tumors. Four HN patient cases covering different clinical situations were planned by MERT, which used an in-house treatment planning system that utilized Monte Carlo dose calculation. The cases included one oronasal, two parotid and one middle ear tumors. The resulting dose-volume histograms were compared with those obtained from conventional photon and electron treatment techniques in our clinic, which included IMRT, electron beam and mixed beams, most of them using fixed-thickness bolus. Experimental verification was performed with plane-parallel ionization chambers for absolute dose verification, and a PTW ionization chamber array and radiochromic film for relative dosimetry. A MC-based treatment planning system for target with compromised volumes in depth and laterally has been validated. A quality assurance protocol for individual MERT plans was launched. Relative MC dose distributions showed a high agreement with film measurements and absolute ion chamber dose measurements performed at a reference point agreed with MC calculations within 2% in all cases. Clinically acceptable PTV coverage and organ-at-risk sparing were achieved by using the proposed MERT approach. MERT treatment plans, based on delivery of intensity-modulated electron beam using the xMLC, for superficial head and neck tumors, demonstrated comparable or improved PTV dose homogeneity with significantly lower dose to normal tissues. The clinical implementation of this technique will be able to offer a viable alternative for the treatment of shallow head and neck tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, L; Eldib, A; Li, J
Purpose: Uneven nose surfaces and air cavities underneath and the use of bolus present complexity and dose uncertainty when using a single electron energy beam to plan treatments of nose skin with a pencil beam-based planning system. This work demonstrates more accurate dose calculation and more optimal planning using energy and intensity modulated electron radiotherapy (MERT) delivered with a pMLC. Methods: An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reducemore » the scatter-caused penumbra, a short SSD (61 cm) was used. Our previous work demonstrates good agreement in percentage depth dose and off-axis dose between calculations and film measurement for various field sizes. A MERT plan was generated for treating the nose skin using a patient geometry and a dose volume histogram (DVH) was obtained. The work also shows the comparison of 2D dose distributions between a clinically used conventional single electron energy plan and the MERT plan. Results: The MERT plan resulted in improved target dose coverage as compared to the conventional plan, which demonstrated a target dose deficit at the field edge. The conventional plan showed higher dose normal tissue irradiation underneath the nose skin while the MERT plan resulted in improved conformity and thus reduces normal tissue dose. Conclusion: This preliminary work illustrates that MC-based MERT planning is a promising technique in treating nose skin, not only providing more accurate dose calculation, but also offering an improved target dose coverage and conformity. In addition, this technique may eliminate the necessity of bolus, which often produces dose delivery uncertainty due to the air gaps that may exist between the bolus and skin.« less
Simultaneous optimization of photons and electrons for mixed beam radiotherapy
NASA Astrophysics Data System (ADS)
Mueller, S.; Fix, M. K.; Joosten, A.; Henzen, D.; Frei, D.; Volken, W.; Kueng, R.; Aebersold, D. M.; Stampanoni, M. F. M.; Manser, P.
2017-07-01
The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct aperture optimization (DAO) is implemented to perform simultaneous optimization of photon and electron apertures, both shaped with the photon multileaf collimator (pMLC). Validated beam models are used as input for Monte Carlo dose calculations. Consideration of photon pMLC transmission during DAO and a weight re-optimization of the apertures after deliverable dose calculation are utilized to efficiently reduce the differences between optimized and deliverable dose distributions. The TPP for MBRT is evaluated for an academic situation with a superficial and an enlarged PTV in the depth, a left chest wall case including the internal mammary chain and a squamous cell carcinoma case. Deliverable dose distributions of MBRT plans are compared to those of modulated electron radiotherapy (MERT), photon IMRT and if available to those of clinical VMAT plans. The generated MBRT plans dosimetrically outperform the MERT, photon IMRT and VMAT plans for all investigated situations. For the clinical cases of the left chest wall and the squamous cell carcinoma, the MBRT plans cover the PTV similarly or more homogeneously than the VMAT plans, while OARs are spared considerably better with average reductions of the mean dose to parallel OARs and D 2% to serial OARs by 54% and 26%, respectively. Moreover, the low dose bath expressed as V 10% to normal tissue is substantially reduced by up to 45% compared to the VMAT plans. A TPP for MBRT including simultaneous optimization is successfully implemented and the dosimetric superiority of MBRT plans over MERT, photon IMRT and VMAT plans is demonstrated for academic and clinical situations including superficial targets with and without deep-seated part.
Simultaneous optimization of photons and electrons for mixed beam radiotherapy.
Mueller, S; Fix, M K; Joosten, A; Henzen, D; Frei, D; Volken, W; Kueng, R; Aebersold, D M; Stampanoni, M F M; Manser, P
2017-06-26
The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct aperture optimization (DAO) is implemented to perform simultaneous optimization of photon and electron apertures, both shaped with the photon multileaf collimator (pMLC). Validated beam models are used as input for Monte Carlo dose calculations. Consideration of photon pMLC transmission during DAO and a weight re-optimization of the apertures after deliverable dose calculation are utilized to efficiently reduce the differences between optimized and deliverable dose distributions. The TPP for MBRT is evaluated for an academic situation with a superficial and an enlarged PTV in the depth, a left chest wall case including the internal mammary chain and a squamous cell carcinoma case. Deliverable dose distributions of MBRT plans are compared to those of modulated electron radiotherapy (MERT), photon IMRT and if available to those of clinical VMAT plans. The generated MBRT plans dosimetrically outperform the MERT, photon IMRT and VMAT plans for all investigated situations. For the clinical cases of the left chest wall and the squamous cell carcinoma, the MBRT plans cover the PTV similarly or more homogeneously than the VMAT plans, while OARs are spared considerably better with average reductions of the mean dose to parallel OARs and D 2% to serial OARs by 54% and 26%, respectively. Moreover, the low dose bath expressed as V 10% to normal tissue is substantially reduced by up to 45% compared to the VMAT plans. A TPP for MBRT including simultaneous optimization is successfully implemented and the dosimetric superiority of MBRT plans over MERT, photon IMRT and VMAT plans is demonstrated for academic and clinical situations including superficial targets with and without deep-seated part.
Jin, Lihui; Eldib, Ahmed; Li, Jinsheng; Emam, Ismail; Fan, Jiajin; Wang, Lu; Ma, C-M
2014-01-06
The dosimetric advantage of modulated electron radiotherapy (MERT) has been explored by many investigators and is considered to be an advanced radiation therapy technique in the utilization of electrons. A computer-controlled electron multileaf collimator (MLC) prototype, newly designed to be added onto a Varian linac to deliver MERT, was investigated both experimentally and by Monte Carlo simulations. Four different electron energies, 6, 9, 12, and 15 MeV, were employed for this investigation. To ensure that this device was capable of delivering the electron beams properly, measurements were performed to examine the electron MLC (eMLC) leaf leakage and to determine the appropriate jaw positioning for an eMLC-shaped field in order to eliminate a secondary radiation peak that could otherwise appear outside of an intended radiation field in the case of inappropriate jaw positioning due to insufficient radiation blockage from the jaws. Phase space data were obtained by Monte Carlo (MC) simulation and recorded at the plane just above the jaws for each of the energies (6, 9, 12, and 15 MeV). As an input source, phase space data were used in MC dose calculations for various sizes of the eMLC shaped field (10 × 10 cm2, 3.4 × 3.4 cm2, and 2 × 2 cm2) with respect to a water phantom at source-to-surface distance (SSD) = 94 cm, while the jaws, eMLC leaves, and some accessories associated with the eMLC assembly as well were modeled as modifiers in the calculations. The calculated results were then compared with measurements from a water scanning system. The results showed that jaw settings with 5 mm margins beyond the field shaped by the eMLC were appropriate to eliminate the secondary radiation peak while not widening the beam penumbra; the eMLC leaf leakage measurements ranged from 0.3% to 1.8% for different energies based on in-phantom measurements, which should be quite acceptable for MERT. Comparisons between MC dose calculations and measurements showed agreement within 1%/1 mm based on percentage depth doses (PDDs) and off-axis dose profiles for a range of field sizes for each of the electron energies. Our current work has demonstrated that the eMLC and other relevant components in the linac were correctly modeled and simulated via our in-house MC codes, and the eMLC is capable of accurately delivering electron beams for various eMLC-shaped field sizes with appropriate jaw settings. In the next stage, patient-specific verification with a full MERT plan should be performed.
Eldib, Ahmed; Li, Jinsheng; Emam, Ismail; Fan, Jiajin; Wang, Lu; Ma, C‐M
2014-01-01
The dosimetric advantage of modulated electron radiotherapy (MERT) has been explored by many investigators and is considered to be an advanced radiation therapy technique in the utilization of electrons. A computer‐controlled electron multileaf collimator (MLC) prototype, newly designed to be added onto a Varian linac to deliver MERT, was investigated both experimentally and by Monte Carlo simulations. Four different electron energies, 6, 9, 12, and 15 MeV, were employed for this investigation. To ensure that this device was capable of delivering the electron beams properly, measurements were performed to examine the electron MLC (eMLC) leaf leakage and to determine the appropriate jaw positioning for an eMLC‐shaped field in order to eliminate a secondary radiation peak that could otherwise appear outside of an intended radiation field in the case of inappropriate jaw positioning due to insufficient radiation blockage from the jaws. Phase space data were obtained by Monte Carlo (MC) simulation and recorded at the plane just above the jaws for each of the energies (6, 9, 12, and 15 MeV). As an input source, phase space data were used in MC dose calculations for various sizes of the eMLC shaped field (10×10 cm2, 3.4×3.4 cm2, and 2×2 cm2) with respect to a water phantom at source‐to‐surface distance (SSD)=94cm, while the jaws, eMLC leaves, and some accessories associated with the eMLC assembly as well were modeled as modifiers in the calculations. The calculated results were then compared with measurements from a water scanning system. The results showed that jaw settings with 5 mm margins beyond the field shaped by the eMLC were appropriate to eliminate the secondary radiation peak while not widening the beam penumbra; the eMLC leaf leakage measurements ranged from 0.3% to 1.8% for different energies based on in‐phantom measurements, which should be quite acceptable for MERT. Comparisons between MC dose calculations and measurements showed agreement within 1%/1mm based on percentage depth doses (PDDs) and off‐axis dose profiles for a range of field sizes for each of the electron energies. Our current work has demonstrated that the eMLC and other relevant components in the linac were correctly modeled and simulated via our in‐house MC codes, and the eMLC is capable of accurately delivering electron beams for various eMLC‐shaped field sizes with appropriate jaw settings. In the next stage, patient‐specific verification with a full MERT plan should be performed. PACS number: 87.55.ne PMID:24423848
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Yizhou, E-mail: yizhou.zhao@dal.ca; Moran, Kathryn; Yewondwossen, Mammo
Three-dimensional (3D) printing is suitable for the fabrication of complex radiotherapy bolus. Although investigated from dosimetric and feasibility standpoints, there are few reports to date of its use for actual patient treatment. This study illustrates the versatile applications of 3D printing in clinical radiation oncology through a selection of patient cases, namely, to create bolus for photon and modulated electron radiotherapy (MERT), as well as applicators for surface high-dose rate (HDR) brachytherapy. Photon boluses were 3D-printed to treat a recurrent squamous cell carcinoma (SCC) of the nasal septum and a basal cell carcinoma (BCC) of the posterior pinna. For amore » patient with a mycosis fungoides involving the upper face, a 3D-printed MERT bolus was used. To treat an SCC of the nose, a 3D-printed applicator for surface brachytherapy was made. The structures' fit to the anatomy and the radiotherapy treatment plans were assessed. Based on the treatment planning computed tomography (CT), the size of the largest air gap at the interface of the 3D-printed structure was 3 mm for the SCC of the nasal septum, 3 mm for the BCC of the pinna, 2 mm for the mycosis fungoides of the face, and 2 mm for the SCC of the nose. Acceptable treatment plans were obtained for the SCC of the nasal septum (95% isodose to 99.8% of planning target volume [PTV]), the BCC of the pinna (95% isodose to 97.7% of PTV), and the mycosis fungoides of the face (90% isodose to 92.5% of PTV). For the latter, compared with a plan with a uniform thickness bolus, the one featuring the MERT bolus achieved relative sparing of all the organs at risk (OARs) distal to the target volume, while maintaining similar target volume coverage. The surface brachytherapy plan for the SCC of the nose had adequate coverage (95% isodose to 95.6% of clinical target volume [CTV]), but a relatively high dose to the left eye, owing to its proximity to the tumor. 3D printing can be implemented effectively in the clinical setting to create highly conformal bolus for photon and MERT, as well as applicators for surface brachytherapy.« less
Clinical applications of 3-dimensional printing in radiation therapy.
Zhao, Yizhou; Moran, Kathryn; Yewondwossen, Mammo; Allan, James; Clarke, Scott; Rajaraman, Murali; Wilke, Derek; Joseph, Paul; Robar, James L
2017-01-01
Three-dimensional (3D) printing is suitable for the fabrication of complex radiotherapy bolus. Although investigated from dosimetric and feasibility standpoints, there are few reports to date of its use for actual patient treatment. This study illustrates the versatile applications of 3D printing in clinical radiation oncology through a selection of patient cases, namely, to create bolus for photon and modulated electron radiotherapy (MERT), as well as applicators for surface high-dose rate (HDR) brachytherapy. Photon boluses were 3D-printed to treat a recurrent squamous cell carcinoma (SCC) of the nasal septum and a basal cell carcinoma (BCC) of the posterior pinna. For a patient with a mycosis fungoides involving the upper face, a 3D-printed MERT bolus was used. To treat an SCC of the nose, a 3D-printed applicator for surface brachytherapy was made. The structures' fit to the anatomy and the radiotherapy treatment plans were assessed. Based on the treatment planning computed tomography (CT), the size of the largest air gap at the interface of the 3D-printed structure was 3 mm for the SCC of the nasal septum, 3 mm for the BCC of the pinna, 2 mm for the mycosis fungoides of the face, and 2 mm for the SCC of the nose. Acceptable treatment plans were obtained for the SCC of the nasal septum (95% isodose to 99.8% of planning target volume [PTV]), the BCC of the pinna (95% isodose to 97.7% of PTV), and the mycosis fungoides of the face (90% isodose to 92.5% of PTV). For the latter, compared with a plan with a uniform thickness bolus, the one featuring the MERT bolus achieved relative sparing of all the organs at risk (OARs) distal to the target volume, while maintaining similar target volume coverage. The surface brachytherapy plan for the SCC of the nose had adequate coverage (95% isodose to 95.6% of clinical target volume [CTV]), but a relatively high dose to the left eye, owing to its proximity to the tumor. 3D printing can be implemented effectively in the clinical setting to create highly conformal bolus for photon and MERT, as well as applicators for surface brachytherapy. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
SU-D-213-06: Dosimetry of Modulated Electron Radiation Therapy Using Fricke Gel Dosimeter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gawad, M Abdel; Elgohary, M; Hassaan, M
Purpose: Modulated electron radiation therapy (MERT) has been proposed as an effective modality for treatment of superficial targets. MERT utilizes multiple beams of different energies which are intensity modulated to deliver optimized dose distribution. Energy independent dosimeters are thus needed for quantitative evaluations of MERT dose distributions and measurements of absolute doses delivered to patients. Thus in the current work we study the feasibility of Fricke gel dosimeters in MERT dosimetry. Methods: Batches of radiation sensitive Fricke gel is fabricated and poured into polymethyl methacrylate cuvettes. The samples were irradiated in solid water phantom and a thick layer of bolusmore » was used as a buildup. A spectrophotometer system was used for measuring the color changes (the absorbance) before and after irradiation and then we calculate net absorbance. We constructed calibration curves to relate the measured absorbance in terms of absorbed dose for all available electron energies. Dosimetric measurements were performed for mixed electron beam delivery and we also performed measurement for segmented field delivery with the dosimeter placed at the junction of two adjacent electron beams of different energies. Dose measured by our gel dosimetry is compared to that calculation from our precise treatment planning system. We also initiated a Monte Carlo study to evaluate the water equivalence of our dosimeters. MCBEAM and MCSIM codes were used for treatment head simulation and phantom dose calculation. PDDs and profiles were calculated for electron beams incident on a phantom designed with 1cm slab of Fricke gel. Results: The calibration curves showed no observed energy dependence with all studied electron beam energies. Good agreement was obtained between dose calculated and that obtained by gel dosimetry. Monte Carlo results illustrated the tissue equivalency of our Gel dosimeters. Conclusion: Fricke Gel dosimeters represent a good option for the dosimetric quality assurance prior to MERT application.« less
Electron beam collimation with a photon MLC for standard electron treatments
NASA Astrophysics Data System (ADS)
Mueller, S.; Fix, M. K.; Henzen, D.; Frei, D.; Frauchiger, D.; Loessl, K.; Stampanoni, M. F. M.; Manser, P.
2018-01-01
Standard electron treatments are currently still performed using standard or molded patient-specific cut-outs placed in the electron applicator. Replacing cut-outs and electron applicators with a photon multileaf collimator (pMLC) for electron beam collimation would make standard electron treatments more efficient and would facilitate advanced treatment techniques like modulated electron radiotherapy (MERT) and mixed beam radiotherapy (MBRT). In this work, a multiple source Monte Carlo beam model for pMLC shaped electron beams commissioned at a source-to-surface distance (SSD) of 70 cm is extended for SSDs of up to 100 cm and validated for several Varian treatment units with field sizes typically used for standard electron treatments. Measurements and dose calculations agree generally within 3% of the maximal dose or 2 mm distance to agreement. To evaluate the dosimetric consequences of using pMLC collimated electron beams for standard electron treatments, pMLC-based and cut-out-based treatment plans are created for a left and a right breast boost, a sternum, a testis and a parotid gland case. The treatment plans consist of a single electron field, either alone (1E) or in combination with two 3D conformal tangential photon fields (1E2X). For each case, a pMLC plan with similar treatment plan quality in terms of dose homogeneity to the target and absolute mean dose values to the organs at risk (OARs) compared to a cut-out plan is found. The absolute mean dose to an OAR is slightly increased for pMLC-based compared to cut-out-based 1E plans if the OAR is located laterally close to the target with respect to beam direction, or if a 6 MeV electron beam is used at an extended SSD. In conclusion, treatment plans using cut-out collimation can be replaced by plans of similar treatment plan quality using pMLC collimation with accurately calculated dose distributions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Connell, T; Papaconstadopoulos, P; Alexander, A
2014-08-15
Modulated electron radiation therapy (MERT) offers the potential to improve healthy tissue sparing through increased dose conformity. Challenges remain, however, in accurate beamlet dose calculation, plan optimization, collimation method and delivery accuracy. In this work, we investigate the accuracy and efficiency of an end-to-end MERT plan and automated-delivery workflow for the electron boost portion of a previously treated whole breast irradiation case. Dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification,more » using an automated motorized tertiary collimator. The automated delivery, which covered 4 electron energies, 196 subfields and 6183 total MU was completed in 25.8 minutes, including 6.2 minutes of beam-on time with the remainder of the delivery time spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. The delivery time could be reduced by 5.3 minutes with minor electron collimator modifications and the beam-on time could be reduced by and estimated factor of 2–3 through redesign of the scattering foils. Comparison of the planned and delivered film dose gave 3%/3 mm gamma pass rates of 62.1, 99.8, 97.8, 98.3, and 98.7 percent for the 9, 12, 16, 20 MeV, and combined energy deliveries respectively. Good results were also seen in the delivery verification performed with a MapCHECK 2 device. The results showed that accurate and efficient MERT delivery is possible with current technologies.« less
Davis, P R; Rickards, A C; Ollerton, J E
2007-12-01
To determine the optimal composition o f the pre-hospital medical response team (MERT) and the value of pre-hospital critical care interventions in a military setting, and specifically to determine both the benefit of including a doctor in the pre-hospital response team and the relevance of the time and distance to definitive care. A comprehensive review of the literature incorporating a range of electronic search engines and hand searches of key journals. There was no level 1 evidence on which to base conclusions. The 15 most relevant articles were analysed in detail. There was one randomized controlled trial (level 2 evidence) that supports the inclusion of a doctor on MERT. Several cohort studies were identified that analysed the benefits of specific critical care interventions in the pre-hospital setting. A doctor with critical care skills deployed on the MERT is associated with improved survival in victims of major trauma. Specific critical care interventions including emergency endotracheal intubation and ventilation, and intercostal drainage are associated with improved survival and functional recovery in certain patients. These benefits appear to be more easily demonstrated for the rural and remote setting than for the urban setting.
Wang, Yi; Li, Dongxun; Wang, Yan; Li, Kewei; Ye, Changyun
2016-01-19
Vibrio parahaemolyticus and Vibrio vulnificus are two marine seafood-borne pathogens causing severe illnesses in humans and aquatic animals. In this study, a recently developed novel multiple endonuclease restriction real-time loop-mediated isothermal amplification technology (MERT-LAMP) were successfully developed and evaluated for simultaneous detection of V. parahaemolyticus and V. vulnificus strains in only a single reaction. Two MERT-LAMP primer sets were designed to specifically target toxR gene of V. parahaemolyticus and rpoS gene of V. vulnificus. The MERT-LAMP reactions were conducted at 62 °C, and the positive results were produced in as short as 19 min with the genomic DNA templates extracted from the V. parahaemolyticus and V. vulnificus strains. The two target pathogens present in the same sample could be simultaneously detected and correctly differentiated based on distinct fluorescence curves in a real-time format. The sensitivity of MERT-LAMP assay was 250 fg and 125 fg DNA per reaction with genomic templates of V. parahaemolyticus and V. vulnificus strains, which was in conformity with conventional LAMP detection. Compared with PCR-based techniques, the MERT-LAMP technology was 100- and 10-fold more sensitive than that of PCR and qPCR methods. Moreover, the limit of detection of MERT-LAMP approach for V. parahaemolyticus isolates and V. vulnificus isolates detection in artificially-contaminated oyster samples was 92 CFU and 83 CFU per reaction. In conclusion, the MERT-LAMP assay presented here was a rapid, specific, and sensitive tool for the detection of V. parahaemolyticus and V. vulnificus, and could be adopted for simultaneous screening of V. parahaemolyticus and V. vulnificus in a wide variety of samples.
Partial wave analysis for folded differential cross sections
NASA Astrophysics Data System (ADS)
Machacek, J. R.; McEachran, R. P.
2018-03-01
The value of modified effective range theory (MERT) and the connection between differential cross sections and phase shifts in low-energy electron scattering has long been recognized. Recent experimental techniques involving magnetically confined beams have introduced the concept of folded differential cross sections (FDCS) where the forward (θ ≤ π/2) and backward scattered (θ ≥ π/2) projectiles are unresolved, that is the value measured at the angle θ is the sum of the signal for particles scattered into the angles θ and π - θ. We have developed an alternative approach to MERT in order to analyse low-energy folded differential cross sections for positrons and electrons. This results in a simplified expression for the FDCS when it is expressed in terms of partial waves and thereby enables one to extract the first few phase shifts from a fit to an experimental FDCS at low energies. Thus, this method predicts forward and backward angle scattering (0 to π) using only experimental FDCS data and can be used to determine the total elastic cross section solely from experimental results at low-energy, which are limited in angular range.
A 'mixed reality' simulator concept for future Medical Emergency Response Team training.
Stone, Robert J; Guest, R; Mahoney, P; Lamb, D; Gibson, C
2017-08-01
The UK Defence Medical Service's Pre-Hospital Emergency Care (PHEC) capability includes rapid-deployment Medical Emergency Response Teams (MERTs) comprising tri-service trauma consultants, paramedics and specialised nurses, all of whom are qualified to administer emergency care under extreme conditions to improve the survival prospects of combat casualties. The pre-deployment training of MERT personnel is designed to foster individual knowledge, skills and abilities in PHEC and in small team performance and cohesion in 'mission-specific' contexts. Until now, the provision of airborne pre-deployment MERT training had been dependent on either the availability of an operational aircraft (eg, the CH-47 Chinook helicopter) or access to one of only two ground-based facsimiles of the Chinook 's rear cargo/passenger cabin. Although MERT training has high priority, there will always be competition with other military taskings for access to helicopter assets (and for other platforms in other branches of the Armed Forces). This paper describes the development of an inexpensive, reconfigurable and transportable MERT training concept based on 'mixed reality' technologies-in effect the 'blending' of real-world objects of training relevance with virtual reality reconstructions of operational contexts. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
SU-E-T-593: Outcomes and Toxicities From a Clinical Trial of APBI Using MERT+IMRT with the Same XMLC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jimenez-Ortega, E.; Ureba, A.; Barbeiro, A.R.
2015-06-15
Purpose: We present the results from a clinical trial of accelerated partial breast irradiation (APBI), using mixed modulated photon and electron beams (MERT+IMRT) with the same photon multileaf collimator (xMLC). Methods: Seven patients were enrolled in the first year of the APBI clinical trial. Patients were selected following the conditions included in the NSABP B-39/RTOG 0413 protocol. The targets and clinically relevant normal structures were contoured on the CT images following this protocol for APBI-EBRT. All treatments were delivered using combined modulated electron and photon beams by means of the same xMLC installed in a SIEMENS Primus linac, with amore » reduced SSD equal to 60 cm for electron beams. The plans were performed with a treatment planning system based on full Monte Carlo simulations, called CARMEN, developed by our group. Simultaneously, an alternative IMRT plan was calculated with the commercial TPS PINNACLE v8.0m (Philips), and both plans were compared. An ad-hoc breast phantom with semi-spherical geometry called NAOMI was designed for a specific QA protocol. Patients received a total dose of 38.5 Gy, delivered in 10 fractions over 5 consecutive days, with a twice-a-day hypofractionated schema.Follow-up visits during 2.5 years on average were repeated at 1 month post-treatment, every 3 months for the first year, and every 6 months for the second year. Toxicity was scored according to National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0). Results: This APBI technique achieved high loco-regional control rates and showed low acute toxicity (grade 1 of CTCAE) and no toxicities from first month onwards. Photographic assessment of cosmesis showed skin excellent results. Conclusion: The clinical results achieved with MERT+IMRT by using the same xMLC are comparable or even better than those obtained with other APBI techniques, thanks to a software solution without any additional equipment or specific device.« less
ERIC Educational Resources Information Center
Cullinan, Paul A.; Merrifield, Philip R.
This document is the final report of the Model Educational Research Training (MERT) program, a graduate program of the New York University School of Education. MERT trains urban school staff in skills necessary to identify problems, design valid research projects, and apply research results. The long-term objective is the training of small groups…
Applicability of modified effective-range theory to positron-atom and positron-molecule scattering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Idziaszek, Zbigniew; Karwasz, Grzegorz; Instytut Fizyki, Uniwersytet Mikolaja Kopernika, 87-100 Torun
2006-06-15
We analyze low-energy scattering of positrons on Ar atoms and N{sub 2} molecules using the modified effective-range theory (MERT) developed by O'Malley, et al. [J. Math. Phys. 2, 491 (1961)]. We use the formulation of MERT based on exact solutions of the Schroedinger equation with polarization potential rather than low-energy expansions of phase shifts into momentum series. We show that MERT describes the experimental data well, provided that effective-range expansion is performed both for s- and p-wave scattering, which dominate in the considered regime of positron energies (0.4-2 eV). We estimate the values of the s-wave scattering length and themore » effective range for e{sup +}-Ar and e{sup +}-N{sub 2} collisions.« less
Wang, Yi; Wang, Yan; Luo, Lijuan; Liu, Dongxin; Luo, Xia; Xu, Yanmei; Hu, Shoukui; Niu, Lina; Xu, Jianguo; Ye, Changyun
2015-01-01
Shigella and Salmonella are frequently isolated from various food samples and can cause human gastroenteritis. Here, a novel multiple endonuclease restriction real-time loop-mediated isothermal amplification technology (MERT-LAMP) were successfully established and validated for simultaneous detection of Shigella strains and Salmonella strains in only a single reaction. Two sets of MERT-LAMP primers for 2 kinds of pathogens were designed from ipaH gene of Shigella spp. and invA gene of Salmonella spp., respectively. Under the constant condition at 63°C, the positive results were yielded in as short as 12 min with the genomic DNA extracted from the 19 Shigella strains and 14 Salmonella strains, and the target pathogens present in a sample could be simultaneously identified based on distinct fluorescence curves in real-time format. Accordingly, the multiplex detection assay significantly reduced effort, materials and reagents used, and amplification and differentiation were conducted at the same time, obviating the use of postdetection procedures. The analytical sensitivity of MERT-LAMP was found to be 62.5 and 125 fg DNA/reaction with genomic templates of Shigella strains and Salmonella strains, which was consist with normal LAMP assay, and at least 10- and 100-fold more sensitive than that of qPCR and conventional PCR approaches. The limit of detection of MERT-LAMP for Shigella strains and Salmonella strains detection in artificially contaminated milk samples was 5.8 and 6.4 CFU per vessel. In conclusion, the MERT-LAMP methodology described here demonstrated a potential and valuable means for simultaneous screening of Shigella and Salmonella in a wide variety of samples. PMID:26697000
Dollarhide, Adrian W; Rutledge, Thomas; Weinger, Matthew B; Dresselhaus, Timothy R
2008-04-01
To determine the feasibility of capturing self-reported medication events using a handheld computer-based Medication Event Reporting Tool (MERT). Handheld computers operating the MERT software application were deployed among volunteer physician (n = 185) and nurse (n = 119) participants on the medical wards of four university-affiliated teaching hospitals. Participants were encouraged to complete confidential reports on the handheld computers for medication events observed during the study period. Demographic variables including age, gender, education level, and clinical experience were recorded for all participants. Each MERT report included details on the provider, location, timing and type of medication event recorded. Over the course of 2,311 days of clinician participation, 76 events were reported; the median time for report completion was 231 seconds. The average event reporting rate for all participants was 0.033 reports per clinician shift. Nurses had a significantly higher reporting rate compared to physicians (0.045 vs 0.026 reports/shift, p = .02). Subgroup analysis revealed that attending physicians reported events more frequently than resident physicians (0.042 vs 0.021 reports/shift, p = .03), and at a rate similar to that of nurses (p = .80). Only 5% of MERT medication events were reported to require increased monitoring or treatment. A handheld-based event reporting tool is a feasible method to record medication events in inpatient hospital care units. Handheld reporting tools may hold promise to augment existing hospital reporting systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
EMAM, M; Eldib, A; Lin, M
2014-06-01
Purpose: An in-house Monte Carlo based treatment planning system (MC TPS) has been developed for modulated electron radiation therapy (MERT). Our preliminary MERT planning experience called for a more user friendly graphical user interface. The current work aimed to design graphical windows and tools to facilitate the contouring and planning process. Methods: Our In-house GUI MC TPS is built on a set of EGS4 user codes namely MCPLAN and MCBEAM in addition to an in-house optimization code, which was named as MCOPTIM. Patient virtual phantom is constructed using the tomographic images in DICOM format exported from clinical treatment planning systemsmore » (TPS). Treatment target volumes and critical structures were usually contoured on clinical TPS and then sent as a structure set file. In our GUI program we developed a visualization tool to allow the planner to visualize the DICOM images and delineate the various structures. We implemented an option in our code for automatic contouring of the patient body and lungs. We also created an interface window displaying a three dimensional representation of the target and also showing a graphical representation of the treatment beams. Results: The new GUI features helped streamline the planning process. The implemented contouring option eliminated the need for performing this step on clinical TPS. The auto detection option for contouring the outer patient body and lungs was tested on patient CTs and it was shown to be accurate as compared to that of clinical TPS. The three dimensional representation of the target and the beams allows better selection of the gantry, collimator and couch angles. Conclusion: An in-house GUI program has been developed for more efficient MERT planning. The application of aiding tools implemented in the program is time saving and gives better control of the planning process.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ureba, A.; Salguero, F. J.; Barbeiro, A. R.
Purpose: The authors present a hybrid direct multileaf collimator (MLC) aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical practice. Methods: The planning system (called CARMEN) is a full MC-TPS, controlled through aMATLAB interface, which is based on the sequencing of a novel map, called “biophysical” map, which is generated from enhanced image data of patients to achieve a set of segments actually deliverable. In order to reducemore » the required computation time, the conventional fluence map has been replaced by the biophysical map which is sequenced to provide direct apertures that will later be weighted by means of an optimization algorithm based on linear programming. A ray-casting algorithm throughout the patient CT assembles information about the found structures, the mass thickness crossed, as well as PET values. Data are recorded to generate a biophysical map for each gantry angle. These maps are the input files for a home-made sequencer developed to take into account the interactions of photons and electrons with the MLC. For each linac (Axesse of Elekta and Primus of Siemens) and energy beam studied (6, 9, 12, 15 MeV and 6 MV), phase space files were simulated with the EGSnrc/BEAMnrc code. The dose calculation in patient was carried out with the BEAMDOSE code. This code is a modified version of EGSnrc/DOSXYZnrc able to calculate the beamlet dose in order to combine them with different weights during the optimization process. Results: Three complex radiotherapy treatments were selected to check the reliability of CARMEN in situations where the MC calculation can offer an added value: A head-and-neck case (Case I) with three targets delineated on PET/CT images and a demanding dose-escalation; a partial breast irradiation case (Case II) solved with photon and electron modulated beams (IMRT + MERT); and a prostatic bed case (Case III) with a pronounced concave-shaped PTV by using volumetric modulated arc therapy. In the three cases, the required target prescription doses and constraints on organs at risk were fulfilled in a short enough time to allow routine clinical implementation. The quality assurance protocol followed to check CARMEN system showed a high agreement with the experimental measurements. Conclusions: A Monte Carlo treatment planning model exclusively based on maps performed from patient imaging data has been presented. The sequencing of these maps allows obtaining deliverable apertures which are weighted for modulation under a linear programming formulation. The model is able to solve complex radiotherapy treatments with high accuracy in an efficient computation time.« less
Ureba, A; Salguero, F J; Barbeiro, A R; Jimenez-Ortega, E; Baeza, J A; Miras, H; Linares, R; Perucha, M; Leal, A
2014-08-01
The authors present a hybrid direct multileaf collimator (MLC) aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical practice. The planning system (called CARMEN) is a full MC-TPS, controlled through aMATLAB interface, which is based on the sequencing of a novel map, called "biophysical" map, which is generated from enhanced image data of patients to achieve a set of segments actually deliverable. In order to reduce the required computation time, the conventional fluence map has been replaced by the biophysical map which is sequenced to provide direct apertures that will later be weighted by means of an optimization algorithm based on linear programming. A ray-casting algorithm throughout the patient CT assembles information about the found structures, the mass thickness crossed, as well as PET values. Data are recorded to generate a biophysical map for each gantry angle. These maps are the input files for a home-made sequencer developed to take into account the interactions of photons and electrons with the MLC. For each linac (Axesse of Elekta and Primus of Siemens) and energy beam studied (6, 9, 12, 15 MeV and 6 MV), phase space files were simulated with the EGSnrc/BEAMnrc code. The dose calculation in patient was carried out with the BEAMDOSE code. This code is a modified version of EGSnrc/DOSXYZnrc able to calculate the beamlet dose in order to combine them with different weights during the optimization process. Three complex radiotherapy treatments were selected to check the reliability of CARMEN in situations where the MC calculation can offer an added value: A head-and-neck case (Case I) with three targets delineated on PET/CT images and a demanding dose-escalation; a partial breast irradiation case (Case II) solved with photon and electron modulated beams (IMRT + MERT); and a prostatic bed case (Case III) with a pronounced concave-shaped PTV by using volumetric modulated arc therapy. In the three cases, the required target prescription doses and constraints on organs at risk were fulfilled in a short enough time to allow routine clinical implementation. The quality assurance protocol followed to check CARMEN system showed a high agreement with the experimental measurements. A Monte Carlo treatment planning model exclusively based on maps performed from patient imaging data has been presented. The sequencing of these maps allows obtaining deliverable apertures which are weighted for modulation under a linear programming formulation. The model is able to solve complex radiotherapy treatments with high accuracy in an efficient computation time.
Overexpression of a bacterial mercury transporter MerT in Arabidopsis enhances mercury tolerance.
Xu, Sheng; Sun, Bin; Wang, Rong; He, Jia; Xia, Bing; Xue, Yong; Wang, Ren
2017-08-19
The phytoremediation by using of green plants in the removal of environmental pollutant is an environment friendly, green technology that is cost effective and energetically inexpensive. By using Agrobacterium-mediated gene transfer, we generated transgenic Arabidopsis plants ectopically expressing mercuric transport protein gene (merT) from Pseudomonas alcaligenes. Compared with wild-type (WT) plants, overexpressing PamerT in Arabidopsis enhanced the tolerance to HgCl 2 . Further results showed that the enhanced total activities or corresponding transcripts of antioxidant enzymes, including superoxide dismutase (SOD), catalase (CAT) and guaiacol peroxidase (POD) were observed in transgenic Arabidopsis under HgCl 2 stress. These results were confirmed by the alleviation of oxidative damage, as indicated by the decrease of thiobarbituric acid reactive substances (TBARS) contents and reactive oxygen species (ROS) accumulation. In addition, localization analysis of PaMerT in Arabidopsis protoplast showed that it is likely to be associated with vacuole. In all, PamerT increased mercury (Hg) tolerance in transgenic Arabidopsis, and decreased production of Hg-induced ROS, thereby protecting plants from oxidative damage. The present study has provided further evidence that bacterial MerT plays an important role in the plant tolerance to HgCl 2 and in reducing the production of ROS induced by HgCl 2 . Copyright © 2017 Elsevier Inc. All rights reserved.
The HRSC on Mars Express: Mert Davies' Involvement in a Novel Planetary Cartography Experiment
NASA Astrophysics Data System (ADS)
Oberst, J.; Waehlisch, M.; Giese, B.; Scholten, F.; Hoffmann, H.; Jaumann, R.; Neukum, G.
2002-12-01
Mert Davies was a team member of the HRSC (High Resolution Stereo Camera) imaging experiment (PI: Gerhard Neukum) on ESA's Mars Express mission. This pushbroom camera is equipped with 9 forward- and backward-looking CCD lines, 5184 samples each, mounted in parallel, perpendicular to the spacecraft velocity vector. Flight image data with resolutions of up to 10m/pix (from an altitude of 250 km) will be acquired line by line as the spacecraft moves. This acquisition strategy will result in 9 separate almost completely overlapping image strips, each of them having more than 27,000 image lines, typically. [HRSC is also equipped with a superresolution channel for imaging of selected targets at up to 2.3 m/pixel]. The combined operation of the nadir and off-nadir CCD lines (+18.9°, 0°, -18.9°) gives HRSC a triple-stereo capability for precision mapping of surface topography and for modelling of spacecraft orbit- and camera pointing errors. The goals of the camera are to obtain accurate control point networks, Digital Elevation Models (DEMs) in Mars-fixed coordinates, and color orthoimages at global (100% of the surface will be covered with resolutions better than 30m/pixel) and local scales. With his long experience in all aspects of planetary geodesy and cartography, Mert Davies was involved in the preparations of this novel Mars imaging experiment which included: (a) development of a ground data system for the analysis of triple-stereo images, (b) camera testing during airborne imaging campaigns, (c) re-analysis of the Mars control point network, and generation of global topographic orthoimage maps on the basis of MOC images and MOLA data, (d) definition of the quadrangle scheme for a new topographic image map series 1:200K, (e) simulation of synthetic HRSC imaging sequences and their photogrammetric analysis. Mars Express is scheduled for launch in May of 2003. We miss Mert very much!
Medical emergency announcements on cruise ships: an audit of outcome.
Taylor, Christopher James
2015-01-01
Public address announcements are an effective way of alerting staff on cruise ships to life -threatening medical emergencies on-board, but should only be used when truly necessary. An audit to investigate the outcome following this method of activating the medical emergency response team (MERT) suggested system flaws. A new elementary first aid training programme for the crew was then developed, emphasising patient assessment and the correct determination of appropriate levels of response. Following fleet-wide implementation, post-intervention audits were performed on two other company ships to evaluate the impact of the new approach. Data from all MERT activations initiated by public address announcement were prospectively collected during the audit periods, including subsequent means of transfer to the ship's medical centre and duration of medical intervention as indicators of clinical severity. After changing the training programme the overall rate of public announcements for medical emergencies fell by 43%. The proportion of patients requiring transfer by stretcher increased from 5% to 33%, whilst the proportion of patients requiring ≥ 4 h of medical intervention increased from 5% to 44%. The audits suggest that the new training programme may have improved the first aid responders' decision-making as there were fewer inappropriate emergency announcements over the public address system. However, two-thirds of all MERT activations were still for patients either well enough to walk or only needing a wheelchair for subsequent transfer, indicating ongoing opportunity for improvement.
NASA Technical Reports Server (NTRS)
Doschek, G. A.; Feldman, U.; Cowan, R. D.
1981-01-01
The paper examines high-resolution solar flare iron line spectra recorded between 1.82 and 1.97 A by a spectrometer flown by the Naval Research Laboratory on an Air Force spacecraft launched on 1979 February 24. The emission line spectrum is due to inner-shell transitions in the ions Fe XX-Fe XXV. Using theoretical spectra and calculations of line intensities obtained by methods discussed by Merts, Cowan, and Magee (1976), electron temperatures as a function of time for two large class X flares are derived. These temperatures are deduced from intensities of lines of Fe XXII, Fe XXIII, and Fe XXIV. The determination of the differential emission measure between about 12-million and 20-million K using these temperatures is considered. The possibility of determining electron densities in flare and tokamak plasmas using the inner-shell spectra of Fe XXI and Fe XX is discussed.
NASA Astrophysics Data System (ADS)
Schmidt, Susan; Schneider, Johannes; Thomas, Klimach; Stephan, Mertes; Ludwig, Schenk; Udo, Kästner; Frank, Stratmann; Joachim, Curtius; Piotr, Kupiszewski; Ernest, Weingartner; Emanuel, Hammer; Paul, Vochezer; Martin, Schnaiter; Stephan, Borrmann
2014-05-01
In the framework of the DFG (deutsche Forschungsgemeinschaft)-funded research unit INUIT (Ice Nuclei research UnIT) a field campaign at the High Alpine Research Station Jungfraujoch (JFJ, Swiss Alps, Sphinx Laboratory, 3580 m asl; 7°59'2''E, 46°32'53''N) took place in January/February 2013 (INUIT-JFJ 2013). The goal of the measurements was to investigate the chemical composition of ice particle residues (IPR) in ambient air as well as the background aerosol particles. Previous investigations conducted at the JFJ showed that particles consisting of mineral components dominate the ice particle residue number (Kamphus et al., 2008) but also particles consisting of black carbon were found to be enriched in IPR (Mertes et al., 2007; Cozic et al., 2008). Cziczo et al. find out that lead as well is a good ice nucleus and was measured in IPR at previous measurements at the JFJ. During INUIT-JFJ 2013, the IPR were sampled out of mixed-phase clouds by an Ice-CVI (Ice Counterflow Virtual Impactor, Mertes et al., 2007) and an ISI (Ice Selective Inlet, Kupiszewski et al., 2013) and analyzed by the single particle mass spectrometer ALABAMA (Aircraft-based Laser Ablation Aerosol Mass Spectrometer; Brands et al., 2011). Additionally, the ALABAMA was connected to a total aerosol-inlet to investigate the chemical composition of background aerosol particles. During 217 hours of background aerosol measurements we analyzed more than 27000 aerosol particles, which consisted mainly of pure organic components or organics mixed with ammonium, metals or mineral components. During six cloud events with approximately 63 h measurement time we detected 162 IPR sampled by the Ice-CVI. The main part of these IPR were also composed of organic material mixed with other chemical compounds. Additionally, we found particles which consisted of mineral components (approximately 23 %). Sampling mixed-phase cloud through the ISI we measured during four cloud events 34 ice residues in approximately 30 h measurement time. The main part of the chemical compounds of these IPR were also organic material mixed with metals or with mineral compounds. We also found a smaller part of particles which consisted of pure mineral components (about 48 %). Lead was also found in the IPR measured behind Ice-CVI (~14 %) as well as in the background aerosol (~0.04 %). Black carbon particles were only found in the background aerosol. Because of the topography of the JFJ, air masses can reach the station only from the northwestern or southeastern direction (Hammer et al., 2013). Back trajectory calculations show that during our measurements the air masses were dominated mainly by long-distance transport from North America over Great Britain and France. This may explain the lower abundance of mineral dust in the ice residues compared to the previous studies. Brands, M., Kamphus, M., Böttger, T., Schneider, J., Drewnick, F., Roth, A., Curtius, J., Voigt, C., Borbon, A., Beekmann, M., Bourdon, A., Perrin, T. and Borrmann, S. (2011) Aerosol Sci. Technol., 45, 46-64. Cozic, J., Mertes, S., Verheggen, B., Cziczo, D. J., Gallavardin, S. J., Walter, S., Baltensperger, U. and Weingartner, E. (2008) J. Geophys. Res.-Atmos., 113, D15209. Cziczo, D. J., Stetzer. O., Worringen, A., Ebert, M., Weinbruch, S., Kamphus, M., Gallavardin, S. J., Curtius, J., Borrmann, S., Froyd, K. D., Mertes, S., Möhler, O., Lohmann, U. (2009) Nature Geoscience, 2, 333-336 Hammer, E., Bukowiecki, N., Gysel, M., Jurányi, Z., Hoyle, C. R., Vogt, R., Baltensperger, U. and Weingartner, E. (2013) Atmos. Chem. Phys. Discuss., 13, 20419-20462 Kamphus, M., Ettner-Mahl, M., Klimach, T., Drewnick, F, Keller, L., Cziczo, D. J., Mertes, S., Borrmann, S. and Curtius1, J. (2010) Atmos. Chem. Phys., 10, 8077-8095. Kupiszewski, P., Weingartner, E., Färber, R., Gysel, M., Hammer, E., Fuchs, C., Baltensperger, U., Vochezer, P., Schnaiter, M., Linke, C., Toprak, E., Mertes, S., Schneider, J., Schmidt, S. (2013) European Aerosol Conference, Prague. Mertes, S., Verheggen, B., Walter,S., Connolly,P., Ebert, M., Schneider, J., Bower, K. N., Cozic, J., Weinbruch, S., Baltensperger, U. and Weingartner, E. (2007) Aerosol Sci. Technol., 41, 848-864.
Theory, simulation and experiments for precise deflection control of radiotherapy electron beams.
Figueroa, R; Leiva, J; Moncada, R; Rojas, L; Santibáñez, M; Valente, M; Velásquez, J; Young, H; Zelada, G; Yáñez, R; Guillen, Y
2018-03-08
Conventional radiotherapy is mainly applied by linear accelerators. Although linear accelerators provide dual (electron/photon) radiation beam modalities, both of them are intrinsically produced by a megavoltage electron current. Modern radiotherapy treatment techniques are based on suitable devices inserted or attached to conventional linear accelerators. Thus, precise control of delivered beam becomes a main key issue. This work presents an integral description of electron beam deflection control as required for novel radiotherapy technique based on convergent photon beam production. Theoretical and Monte Carlo approaches were initially used for designing and optimizing device´s components. Then, dedicated instrumentation was developed for experimental verification of electron beam deflection due to the designed magnets. Both Monte Carlo simulations and experimental results support the reliability of electrodynamics models used to predict megavoltage electron beam control. Copyright © 2018 Elsevier Ltd. All rights reserved.
Recent advances in radiation cancer therapy
NASA Astrophysics Data System (ADS)
Ma, C.-M. Charlie
2007-03-01
This paper presents the recent advances in radiation therapy techniques for the treatment of cancer. Significant improvement has been made in imaging techniques such as CT, MRI, MRS, PET, ultrasound, etc. that have brought marked advances in tumor target and critical structure delineation for treatment planning and patient setup and target localization for accurate dose delivery in radiation therapy of cancer. Recent developments of novel treatment modalities including intensity-modulated x-ray therapy (IMXT), energy- and intensity modulated electron therapy (MERT) and intensity modulated proton therapy (IMPT) together with the use of advanced image guidance have enabled precise dose delivery for dose escalation and hypofractionation studies that may result in better local control and quality of life. Particle acceleration using laser-induced plasmas has great potential for new cost-effective radiation sources that may have a great impact on the management of cancer using radiation therapy.
Barnard, E B G; Moy, R J; Kehoe, A D; Bebarta, V S; Smith, J E
2015-06-01
Intraosseous (IO) drug infusion has been reported to have similar pharmacokinetics to intravenous (IV) infusion. In military and civilian trauma, the IO route is often used to obtain rapid and reliable parenteral access for drug administration. Only a few case reports have described the use of IO infusion to administer drugs for rapid sequence induction of anaesthesia (RSI). We aimed to assess the feasibility of the administration of RSI drugs via an IO catheter in a prospective observational study. A prospective observational study was undertaken at a combat hospital in Afghanistan. A validated data form was used to record the use of IO drugs for RSI by the prehospital, physician-led Medical Emergency Response Team (MERT), and by inhospital physicians. Data were captured between January and May 2012 by interview with MERT physicians and inhospital physicians directly after RSI. The primary outcome measure was the success rate of first-pass intubation with direct laryngoscopy. 34 trauma patients (29 MERT and 5 inhospital) underwent RSI with IO drug administration. The median age was 24 years and median injury severity score 25; all were male. The predominant mechanism of injury was blast (n=24), followed by penetrating (n=6), blunt (n=3) and burn (n=1). First-pass intubation success rate was 97% (95% CI 91% to 100%). A Cormack-Lehane grade 1 view, by direct laryngoscopy, was obtained at first look in 91% (95% CI 81% to 100%) of patients. In this prospective, observational study, IO drug administration was successfully used for trauma RSI, with a comparable first pass intubation success than published studies describing the IV route. RCDM/Res/Audit/1036/12/0162. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Mert Davies: Pioneer in the Use of Spacecraft to Map Earth and Mars
NASA Astrophysics Data System (ADS)
Murray, B.; Augenstein, B.
2002-12-01
Mert Davies was one of the founding employees of the RAND Corporation in 1946, and continued that relationship until his death in 2001. He began his involvement in satellite imaging at Rand as one of about 100 researchers in Project Feedback in 1954, provided the basis for the initial US military space program. In 1957, in response to the Soviet launch of Sputnik, Mert and a small group of Rand cohorts proposed a family of recoverable reconnaissance satellites featuring spin stabilized cameras, for which he later received a patent. This work, now declassified, was for a short time considered as a basis for the Corona, America's first reconnaissance satellite Corona, although ultimately alternative technologies were employed. In addition he was looking beyond Earth quite early and in May, 1958 published an analysis of a lunar mapping satellite. The 1957 work at Rand spurred considerations of space-based geodesy and mapping. These and other early contributions were recognized in 1999 by the National Reconnaissance Office which honored him as one of the founders of national reconnaissance. He was so enthused by the opportunity developing in the mid 1960?s to explore photographically the planets that he changed careers and joined the Television Team of the Mariner probes being developed to flyby Mars in 1969 (Mariner's 6&7). His abilities and accomplishments there led directly to central roles later in the Mariner 9 Mars Orbiter mission (1971-72) as well as Mariner 10 to Mercury (1973-75) and Voyagers 1&2 (1979-89) These early flights to Mars represented unprecedented technical challenges, especially to radio communications. As a consequence, analog television systems, like that carried on the Ranger impact probe in 1964-65 or film readout technology like that used on Lunar Orbiter in 1965-66 to send back high-resolution images from the Moon were not feasible from planetary distances. In order to exploit the remarkable communication potential of the DSN, JPL-based television teams invented the world?s first digital television cameras using primitive slow-scan vidicon sensors in order to overcome the 200-fold greater distance to Mars. Spacecraft mapping and geodesy was initiated by the dual flybys Mariner 6 and 7 of 1969, each carrying a moderately high resolution optical system, but one plagued by the geometric limitations of a vidicon sensor necessarily using imprecise electro-optical imaging internally. He understood clearly that the number of resolution elements on the Mariner 6/7 cameras were too small for good photogrammetric solutions. Each picture contained only 70,000 resolution elements compared to a standard aerial photograph with about a third of a billion of comparable elements. Despite such limitations, Mert was able to exploit especially the far encounter imaging from Mariners 6/7 to create the first Mars surface control net based on topographic features, and to solve for the position of the rotational pole. Under his leadership, the Mariner 9 orbiter mission greatly expanded that coverage, providing the evolving basis of USGS Mars mapping practically until the present. Furthermore, Mert, in conjunction with Harold Masursky and Gerard de Vaucoleurs, established the topocentric reference point for the prime meridian on Mars as the small crater Airy-O, which thus occupies a role analogous to that of Greenwich, England for the Earth. He was to play that historic prime meridian role for nearly all the solid bodies in the Solar System over the ensuing decades as well as a continuing role on the IAU committee that named officially the surface features of Mercury, Venus, Mars, and the satellites of Jupiter, Saturn, Uranus.
Applicability of Topaz Composites to Electron Dosimetry
NASA Astrophysics Data System (ADS)
Bomfim, K. S.; Souza, D. N.
2010-11-01
Thermoluminescent dosimetric topaz properties have been investigated and the results have shown that this mineral presents characteristics of a good dosimeter mainly in doses evaluation in radiotherapy with photons beams in radiotherapy. Typical applications of thermoluminescent dosimeters in radiotherapy are: in vivo dosimetry on patients (either as a routine quality assurance procedure or for dose monitoring in special cases); verification of treatment techniques; dosimetry audits; and comparisons among hospitals. The mean aim of this work was to evaluate the efficiency of topaz-Teflon pellets as thermoluminescent dosimeters in high-energy electron beams used to radiotherapy. Topaz-Teflon pellets were used as TLD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tomar, Vikas
Irradiations and post characterization experiments were performed first on Zr samples. This step will help understand the effect of the 2.5% alloying elements on the behavior of Zircaloy-4 (PWR cladding material) when compared to pure Zr. Irradiation flux measurements and sample temperature calibrations were performed at different energies prior to the irradiation experiments. Irradiations were performed with two different energy regimes1: non-displacment energies and displacement energies. Time was also dedicated to optimize transmission electron microscopy (TEM) sample preparation conditions via electropolishing technique. This step is crucial to prepare TEM samples for the in-situ TEM/irradiation experiments (Year 2). In addition, Zircaloy-4more » samples are being prepared for irradiation, and a setup is built by one of our collaborators (Dr. Mert Efe) to prepare ultrafine (UF) and nanocrystalline (NC) Zircaloy-4 samples for comparison with the commercial Zircaloy-4 samples.« less
Jan, Arif Tasleem; Azam, Mudsser; Choi, Inho; Ali, Arif; Haq, Qazi Mohd. Rizwanul
2016-01-01
Mercury, which is ubiquitous and recalcitrant to biodegradation processes, threatens human health by escaping to the environment via various natural and anthropogenic activities. Non-biodegradability of mercury pollutants has necessitated the development and implementation of economic alternatives with promising potential to remove metals from the environment. Enhancement of microbial based remediation strategies through genetic engineering approaches provides one such alternative with a promising future. In this study, bacterial isolates inhabiting polluted sites were screened for tolerance to varying concentrations of mercuric chloride. Following identification, several Pseudomonas and Klebsiella species were found to exhibit the highest tolerance to both organic and inorganic mercury. Screened bacterial isolates were examined for their genetic make-up in terms of the presence of genes (merP and merT) involved in the transport of mercury across the membrane either alone or in combination to deal with the toxic mercury. Gene sequence analysis revealed that the merP gene showed 86–99% homology, while the merT gene showed >98% homology with previously reported sequences. By exploring the genes involved in imparting metal resistance to bacteria, this study will serve to highlight the credentials that are particularly advantageous for their practical application to remediation of mercury from the environment. PMID:26887227
Boiling heat transfer to LN2 and LH2 - Influence of surface orientation and reduced body forces
NASA Technical Reports Server (NTRS)
Merte, H., Jr.; Oker, E.; Littles, J. W.
1973-01-01
The quantitative determination of the influence of heater surface orientation and gravity on nucleate pool boiling of liquid nitrogen and liquid hydrogen is described. A transient calorimeter technique, well suited for obtaining pool boiling data under reduced gravity and used earlier by Clark and Merte (1963), was employed after being adapted to flat a surface whose orientation could be varied. The obtained determination results are reviewed.
Partial breast radiotherapy with simple teletherapy techniques.
Fekete, Gábor; Újhidy, Dóra; Együd, Zsófia; Kiscsatári, Laura; Marosi, Gusztáv; Kahán, Zsuzsanna; Varga, Zoltán
2015-01-01
A prospective pilot study of partial breast irradiation (PBI) with conventional vs hypofractionated schedules was set out. The study aimed to determine efficacy, acute and late side effects, and the preference of photon vs electron irradiation based on individual features. Patients were enrolled according to internationally accepted guidelines on PBI. Conformal radiotherapy plans were generated with both photon and electron beams, and the preferred technique based on dose homogeneity and the radiation exposure of healthy tissues was applied. For electron dose verification, a special phantom was constructed. Patients were randomized for fractionation schedules of 25 × 2 vs 13 × 3Gy. Skin and breast changes were registered at the time of and ≥1 year after the completion of radiotherapy. Dose homogeneity was better with photons. If the tumor bed was located in the inner quadrants, electron beam gave superior results regarding conformity and sparing of organ at risk (OAR). If the tumor was situated in the lateral quadrants, conformity was better with photons. A depth of the tumor bed ≥3.0cm predicted the superiority of photon irradiation (odds ratio [OR] = 23.6, 95% CI: 5.2 to 107.5, p < 0.001) with >90% sensitivity and specificity. After a median follow-up of 39 months, among 72 irradiated cases, 1 local relapse out of the tumor bed was detected. Acute radiodermatitis of grade I to II, hyperpigmentation, and telangiectasia developed ≥1 year after radiotherapy, exclusively after electron beam radiotherapy. The choice of electrons or photons for PBI should be based on tumor bed location; the used methods are efficient and feasible. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
1987-08-05
03824 Dr. Ronald Breslow Columbia University Departmont of Cemistry New York, NY 10027 Dr. James P. Colmen Department of Cmistry Stanford University...of Massachusetts Amherst, MA 01003 Dr. Harden M. McConnell Stanford Univesity Department of Cemistry Stanford, CA 94305 Dr. Kristin lowtmn Mertes...Institute of Technology Cambridge, MA 02139 Dr. J. H. Richards California Institute of Technology Division of Cemistry and Ch e.cal Engineering
Maarouf, Mohammad; Schleicher, Ursula; Schmachtenberg, Axel; Ammon, Jürgen
2002-06-01
Aim of this study was to evaluate the advantages of electron beam irradiation compared to kilovoltage X-ray therapy in the treatment of keloids. Furthermore, the risk of developing malignancy following keloid radiotherapy was assessed. An automatic water phantom was used to evaluate the dose distribution in tissue. Furthermore, a series of measurements was done on the patients using thermoluminescence dosimeters (TLD) to estimate the doses absorbed by the organs at risk. We also report our clinical experience with electron beam radiation of 134 keloids following surgical excision. Electron beam irradiation offers a high control rate (84%) with minimal side effects for keloids. Electron irradiation provides better dose distribution in tissue, and therefore less radiation burden to the organs at risk. After a mean follow-up period of 7.2 years, no severe side effects or malignancies were observed after keloid radiotherapy. Electron radiation therapy is superior to kilovoltage irradiation for treating keloids due to better dose distribution in tissue. In agreement with the literature, no cases of malignancy were observed after keloid irradiation.
Formal Methods for Biological Systems: Languages, Algorithms, and Applications
2016-09-01
Moura. The yices SMT solver. Tool paper at http://yices.csl.sri.com/tool-paper. pdf, 2:2, 2006. 1.2 [80] Volker Ellenrieder, Martin E Fernandez Zapico...Oncology, 32(3):128–131, 2010. 6 [82] Mert Erkan, Simone Hausmann, Christoph W Michalski, Alexander A Fingerle, Martin Dobritz, Jörg Kleeff, and...data. In International Conference on Computer Aided Verification, pages 544–560. Springer, 2015. 1.1 [91] Martin Fränzle, Holger Hermanns, and Tino
Impact of the AF Milcon (Military Construction) Funding Shortfall Alternatives and Recommendations.
1988-04-01
mix of NM and CM reqg.: eMertEs Theoretically, in an unconstrained funding environr-r.t, tne annual Milcon request would include the sum of all W and... market fall of 19 October 1987, and the record decline in the strength of the dollar. Furthermore, in a press conference 22 October 1987, President...APPENDIX APPENDIX A: MILCON ALLOCATION STATEGY EXCERPT FROM CORONA SOUTH CONFERENCE, (19:1-8) APPEND!:. B: PICTC)RIAL rODEL OF PROPOSED CHANGE TO
Military Review. Volume 58, Number 9
1978-09-01
broad panty w1th the modest military capab11it1es of the nation’s more substantial neighbors (most particularly Argentma). ~ Unswerv1ng allegiance to...than panty w1th Argentina m the Platma Basm or pro1ectmg much m the way of mfluence to other port1ons of the con- tment On the world stage...secunty affatrs Regionally, Brazil’s secunty posture was relatively mert. atmed only at the mamtenance of broad panty m capacity and mfluence wtth 1ts
Cisplatin-tethered gold nanospheres for multimodal chemo-radiotherapy of glioblastoma
NASA Astrophysics Data System (ADS)
Setua, Sonali; Ouberai, Myriam; Piccirillo, Sara G.; Watts, Colin; Welland, Mark
2014-08-01
Glioblastoma multiforme (GBM) remains the most aggressive and challenging brain tumour to treat. We report the first successful chemo-radiotherapy on patient derived treatment resistant GBM cells using a cisplatin-tethered gold nanosphere. After intracellular uptake, the nanosphere effects DNA damage which initiates caspase-mediated apoptosis in those cells. In the presence of radiation, both gold and platinum of cisplatin, serve as high atomic number radiosensitizers leading to the emission of ionizing photoelectrons and Auger electrons. This resulted in enhanced synergy between cisplatin and radiotherapy mediated cytotoxicity, and photo/Auger electron mediated radiosensitisation leading to complete ablation of the tumour cells in an in vitro model system. This study demonstrates the potential of designed nanoparticles to target aggressive cancers in the patient derived cell lines providing a platform to move towards treatment strategies.Glioblastoma multiforme (GBM) remains the most aggressive and challenging brain tumour to treat. We report the first successful chemo-radiotherapy on patient derived treatment resistant GBM cells using a cisplatin-tethered gold nanosphere. After intracellular uptake, the nanosphere effects DNA damage which initiates caspase-mediated apoptosis in those cells. In the presence of radiation, both gold and platinum of cisplatin, serve as high atomic number radiosensitizers leading to the emission of ionizing photoelectrons and Auger electrons. This resulted in enhanced synergy between cisplatin and radiotherapy mediated cytotoxicity, and photo/Auger electron mediated radiosensitisation leading to complete ablation of the tumour cells in an in vitro model system. This study demonstrates the potential of designed nanoparticles to target aggressive cancers in the patient derived cell lines providing a platform to move towards treatment strategies. Electronic supplementary information (ESI) available: Additional figures. See DOI: 10.1039/c4nr03693j
Considerations of MCNP Monte Carlo code to be used as a radiotherapy treatment planning tool.
Juste, B; Miro, R; Gallardo, S; Verdu, G; Santos, A
2005-01-01
The present work has simulated the photon and electron transport in a Theratron 780® (MDS Nordion)60Co radiotherapy unit, using the Monte Carlo transport code, MCNP (Monte Carlo N-Particle). This project explains mainly the different methodologies carried out to speedup calculations in order to apply this code efficiently in radiotherapy treatment planning.
Review on heavy ion radiotherapy facilities and related ion sources (invited)a)
NASA Astrophysics Data System (ADS)
Kitagawa, A.; Fujita, T.; Muramatsu, M.; Biri, S.; Drentje, A. G.
2010-02-01
Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four facilities for heavy ion radiotherapy in operation, and several new facilities are under construction or being planned. The most common requests for ion sources are a long lifetime and good stability and reproducibility. Sufficient intensity has been achieved by electron cyclotron resonance ion sources at the present facilities.
Covington, James A.; Wedlake, Linda; Andreyev, Jervoise; Ouaret, Nathalie; Thomas, Matthew G.; Nwokolo, Chuka U.; Bardhan, Karna D.; Arasaradnam, Ramesh P.
2012-01-01
It is well known that the electronic nose can be used to identify differences between human health and disease for a range of disorders. We present a pilot study to investigate if the electronic nose and a newer technology, FAIMS (Field Asymmetric Ion Mobility Spectrometry), can be used to identify and help inform the treatment pathway for patients receiving pelvic radiotherapy, which frequently causes gastrointestinal side-effects, severe in some. From a larger group, 23 radiotherapy patients were selected where half had the highest levels of toxicity and the others the lowest. Stool samples were obtained before and four weeks after radiotherapy and the volatiles and gases emitted analysed by both methods; these chemicals are products of fermentation caused by gut microflora. Principal component analysis of the electronic nose data and wavelet transform followed by Fisher discriminant analysis of FAIMS data indicated that it was possible to separate patients after treatment by their toxicity levels. More interestingly, differences were also identified in their pre-treatment samples. We believe these patterns arise from differences in gut microflora where some combinations of bacteria result to give this olfactory signature. In the future our approach may result in a technique that will help identify patients at “high risk” even before radiation treatment is started. PMID:23201982
Evaluating 99mTc Auger electrons for targeted tumor radiotherapy by computational methods.
Tavares, Adriana Alexandre S; Tavares, João Manuel R S
2010-07-01
Technetium-99m (99mTc) has been widely used as an imaging agent but only recently has been considered for therapeutic applications. This study aims to analyze the potential use of 99mTc Auger electrons for targeted tumor radiotherapy by evaluating the DNA damage and its probability of correct repair and by studying the cellular kinetics, following 99mTc Auger electron irradiation in comparison to iodine-131 (131I) beta minus particles and astatine-211 (211At) alpha particle irradiation. Computational models were used to estimate the yield of DNA damage (fast Monte Carlo damage algorithm), the probability of correct repair (Monte Carlo excision repair algorithm), and cell kinetic effects (virtual cell radiobiology algorithm) after irradiation with the selected particles. The results obtained with the algorithms used suggested that 99mTc CKMMX (all M-shell Coster-Kroning--CK--and super-CK transitions) electrons and Auger MXY (all M-shell Auger transitions) have a therapeutic potential comparable to high linear energy transfer 211At alpha particles and higher than 131I beta minus particles. All the other 99mTc electrons had a therapeutic potential similar to 131I beta minus particles. 99mTc CKMMX electrons and Auger MXY presented a higher probability to induce apoptosis than 131I beta minus particles and a probability similar to 211At alpha particles. Based on the results here, 99mTc CKMMX electrons and Auger MXY are useful electrons for targeted tumor radiotherapy.
Zeinali-Rafsanjani, B; Faghihi, R; Mosleh-Shirazi, M A; Saeedi-Moghadam, M; Jalli, R; Sina, S
2018-01-01
MRI-only treatment planning (TP) can be advantageous in paediatric radiotherapy. However, electron density extraction is necessary for dose calculation. Normally, after bone segmentation, a bulk density is assigned. However, the variation of bone bulk density in patients makes the creation of pseudo CTs challenging. This study aims to assess the effects of bone density variations in children on radiation attenuation and dose calculation for MRI-only TP. Bone contents of <15-year-old children were calculated, and substituted in the Oak Ridge National Laboratory paediatric phantoms. The percentage depth dose and beam profile of 150 kVp and 6 MV photon and 6 MeV electron beams were then calculated using Xcom, MCNPX (Monte Carlo N-particle version X) and ORLN phantoms. Using 150 kVp X-rays, the difference in attenuation coefficient was almost 5% between an 11-year-old child and a newborn, and ~8% between an adult and a newborn. With megavoltage radiation, the differences were smaller but still important. For an 18 MV photon beam, the difference of radiation attenuation between an 11-year-old child and a newborn was 4% and ~7.4% between an adult and a newborn. For 6 MeV electrons, dose differences were observed up to the 2 cm depth. The percentage depth dose difference between 1 and 10-year-olds was 18.5%, and between 10 and 15-year-olds was 24%. The results suggest that for MRI-only TP of photon- or electron-beam radiotherapy, the bone densities of each age group should be defined separately for accurate dose calculation. Advances in knowledge: This study highlights the need for more age-specific determination of bone electron density for accurate dose calculations in paediatric MRI-only radiotherapy TP.
[Radiotherapy of squamous cell carcinomas of the tongue--a statistical review].
Kubo, K; Furukawa, S; Fuchihata, H; Nakamura, M; Shimizutani, K; Nishiyama, K; Ikeda, H; Masaki, N
1989-01-01
The cases of 36 patients referred for radiotherapy of the tongue after an excisional biopsy or after an inadequate excision of the tongue cancer have been reviewed. In 32 patients treated by radiotherapy, the actuarial survival rate at five years was 86%, and the local rate control, was 82%. The local control rate for those treated by interstitial radiotherapy (Int. RT) was successful in 12 out of 13 cases, and the rates for those treated by external radiotherapy (Ext. RT) followed by Int. RT, or by the intraoral cone technique with electron beams (Elec.), or by Ext. RT, or by Elec. followed by Int. RT, or by no additional therapy were 7 out of 9, 4 out of 5, 2 out of 4, 1 out of 1, and 2 out of 4, respectively. For such cases of cancer, subsequent interstitial radiotherapy is advisable to maintain local control.
Calvo, F A; Santos, M; Azinovic, I
1998-01-01
Intraoperative radiotherapy is a technique that can be integrated into multidisciplinary treatment strategies in oncology. A radiation boost delivered with high energy electron beams can intensify locoregional antitumor therapy in patients undergoing cancer surgery. Intraoperative radiotherapy can increase the therapeutic index of the conventional combination of surgery and radiotherapy by improving the precision of radiation dose location, while decreasing the normal tissue damage in mobile structures and enhancing the biological effect of radiation when combined with surgical debulking. Intraoperative radiotherapy has been extensively investigated in clinical oncology in the last 15 years. Commercially available linear accelerators require minimal changes to be suitable for intraoperative radiotherapy. Its successful implementation in clinical protocols depends on the support given by the single institutions and on a clinical research-oriented mentality. Tumors where intraoperative radiotherapy as a treatment component has shown promising rates of local control include locally advanced rectal, gastric and gynecologic cancer, bone and soft tissue sarcoma. Intraoperative radiotherapy can be applied to brain tumors, head and neck cancer, NSCLC and pancreatic carcinoma.
[Description and histology identification of several algae of Sargassum sp].
Dong, Yan; Li, Yushan; Cui, Zheng; Zhang, Zhicheng; Liu, Dongchun; Wang, Chunyang
2002-04-01
This paper reported the description characters and microscopical identification of seven kinds of algae of Sargassum sp., Sargassum pallidum (Tum.) C. Ag., S. fusiforme (Harv.) Setch., S. horneri (Tum.) C. Ag., S. hemiphyllum (Turh.) C. Ag., S. thunbergii (Mert.) O'Kuntze, S. polycystum C. Ag. and S. kjellmanianum Yendo. The results revealed that there were clear differences in the description characters and microscopical identification of the seven kinds of algae of Sargassum sp. These studies provided a scientific basis for distinguishing crude drug of algae, developing and making use of alga natural resources of Sargassum sp.
SU-E-J-198: Out-Of-Field Dose and Surface Dose Measurements of MRI-Guided Cobalt-60 Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamb, J; Agazaryan, N; Cao, M
2015-06-15
Purpose: To measure quantities of dosimetric interest in an MRI-guided cobalt radiotherapy machine that was recently introduced to clinical use. Methods: Out-of-field dose due to photon scatter and leakage was measured using an ion chamber and solid water slabs mimicking a human body. Surface dose was measured by irradiating stacks of radiochromic film and extrapolating to zero thickness. Electron out-of-field dose was characterized using solid water slabs and radiochromic film. Results: For some phantom geometries, up to 50% of Dmax was observed up to 10 cm laterally from the edge of the beam. The maximum penetration was between 1 andmore » 2 mm in solid water, indicating an electron energy not greater than approximately 0.4 MeV. Out-of-field dose from photon scatter measured at 1 cm depth in solid water was found to fall to less than 10% of Dmax at a distance of 1.2 cm from the edge of a 10.5 × 10.5 cm field, and less that 1% of Dmax at a distance of 10 cm from field edge. Surface dose was measured to be 8% of Dmax. Conclusion: Surface dose and out-of-field dose from the MRIguided cobalt radiotherapy machine was measured and found to be within acceptable limits. Electron out-of-field dose, an effect unique to MRI-guided radiotherapy and presumed to arise from low-energy electrons trapped by the Lorentz force, was quantified. Dr. Low is a member of the scientific advisory board of ViewRay, Inc.« less
Radiotherapy Improvements by Using Au Nanoparticles.
Torrisi, Lorenzo
2015-01-01
Au nanoparticles can be prepared inside biological solutions and incorporated in special molecules for their transport through blood, drugs and proteins up to the tumour sites or directly injected in their volume when it is possible. The Au nanoparticles are biocompatible and can be accepted locally in the organism also at relatively high concentrations. The use of Au nanoparticles injected in the tumour site enhances significantly the effective atomic number of the medium, depending on the used concentration, and consequently the proton and electron energy loss and the X-ray absorption coefficient determining an increment of the local absorbed dose during radiotherapy. Traditional radiotherapy using electrons, X-rays and gamma rays, and innovative protontherapy can benefit the increment of the effective atomic number of the tissue in the presence of Au-nanoparticles embedded in the tumour volume with an adaptive up-take procedure. This method decreases the dose released to the healthy tissues permitting a better cantering of the irradiated targets and shielding the healthy tissue placed behind the tumour. The presented theoretical study approach permits to evaluate an enhancement of the radiotherapy dose of the order of 1 % using 60 MeV protons, of the order of 10% using 6 MeV electrons and of the order of 100 % using 100 keV X-ray photons. Here, we also disccused for patents relaed to the topic.
Precision radiotherapy for cancer of the pancreas: technique and results. [Photons and electrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dobelbower, R.R. Jr.; Borgelt, B.B.; Strubler, K.A.
1980-09-01
Forty patients with locally extensive, unresectable adenocarcinoma of the pancreas received precision high dose (PHD) radiation therapy with a 45 MeV betatron. PHD radiotherapy was generally well tolerated. During treatment, only 7 patients experienced significant nausea, vomiting, diarrhea or anorexia. Late gastrointestinal radiation reactions were observed in 7 patients. Twelve patients received adjuvant chemotherapy. The projected survival of patients with unresectable pancreatic cancer treated with PHD radiotherapy is comparable to that of patients with resectable disease operated on for cure. The projected one year survival rate is 49%.
NASA Astrophysics Data System (ADS)
Barón-Aznar, C.; Moreno-Jiménez, S.; Celis, M. A.; Lárraga-Gutiérrez, J. M.; Ballesteros-Zebadúa, P.
2008-08-01
Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScansoftware, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed.
Juste, B; Miro, R; Gallardo, S; Santos, A; Verdu, G
2006-01-01
The present work has simulated the photon and electron transport in a Theratron 780 (MDS Nordion) (60)Co radiotherapy unit, using the Monte Carlo transport code, MCNP (Monte Carlo N-Particle), version 5. In order to become computationally more efficient in view of taking part in the practical field of radiotherapy treatment planning, this work is focused mainly on the analysis of dose results and on the required computing time of different tallies applied in the model to speed up calculations.
Updates on clinical studies of selenium supplementation in radiotherapy
2014-01-01
To establish guidelines for the selenium supplementation in radiotherapy we assessed the benefits and risks of selenium supplementation in radiotherapy. Clinical studies on the use of selenium in radiotherapy were searched in the PubMed electronic database in January 2013. Sixteen clinical studies were identified among the 167 articles selected in the initial search. Ten articles were observational studies, and the other 6 articles reported studies on the effects of selenium supplementation in patients with cancer who underwent radiotherapy. The studies were conducted worldwide including European, American and Asian countries between 1987 and 2012. Plasma, serum or whole blood selenium levels were common parameters used to assess the effects of radiotherapy and the selenium supplementation status. Selenium supplementation improved the general conditions of the patients, improved their quality of life and reduced the side effects of radiotherapy. At the dose of selenium used in these studies (200–500 μg/day), selenium supplementation did not reduce the effectiveness of radiotherapy, and no toxicities were reported. Selenium supplementation may offer specific benefits for several types of cancer patients who undergo radiotherapy. Because high-dose selenium and long-term supplementation may be unsafe due to selenium toxicity, more evidence-based information and additional research are needed to ensure the therapeutic benefits of selenium supplementation. PMID:24885670
Design of 6 MeV X-band electron linac for dual-head gantry radiotherapy system
NASA Astrophysics Data System (ADS)
Shin, Seung-wook; Lee, Seung-Hyun; Lee, Jong-Chul; Kim, Huisu; Ha, Donghyup; Ghergherehchi, Mitra; Chai, Jongseo; Lee, Byung-no; Chae, Moonsik
2017-12-01
A compact 6 MeV electron linac is being developed at Sungkyunkwan University, in collaboration with the Korea atomic energy research institute (KAERI). The linac will be used as an X-ray source for a dual-head gantry radiotherapy system. X-band technology has been employed to satisfy the size requirement of the dual-head gantry radiotherapy machine. Among the several options available, we selected a pi/2-mode, standing-wave, side-coupled cavity. This choice of radiofrequency (RF) cavity design is intended to enhance the shunt impedance of each cavity in the linac. An optimum structure of the RF cavity with a high-performance design was determined by applying a genetic algorithm during the optimization procedure. This paper describes the detailed design process for a single normal RF cavity and the entire structure, including the RF power coupler and coupling cavity, as well as the beam dynamics results.
Two Hour Evaluation and Referral Model for Shorter Turnaround Times in the emergency department.
Burke, John A; Greenslade, Jaimi; Chabrowska, Jadwiga; Greenslade, Katherine; Jones, Sally; Montana, Jacqueline; Bell, Anthony; O'Connor, Alan
2017-06-01
The objective of this study was to assess the implementation of a novel ED model of care, which combines clinical streaming, team-based assessment and early senior consultation to reduce length of stay. A pre-post-intervention study was used to compare ED performance following an extensive clinical redesign programme. Clinical teams and work sequences were reconfigured to promote the role of the staff specialist, with a focus on earlier decisions regarding disposition. Primary outcome measures were ED length of stay and National Emergency Access Target (NEAT) compliance. Secondary outcomes included referral and workup times, wait times by triage category, ambulance offload times, ward discharges and unit transfers within 24 h of admission, representation within 48 h, and Medical Emergency Response Team (MERT) calls within 24 h of admission. Two seasonally matched 26 week intervals were compared with adjustment for demographics, triage category and arrival by ambulance. Overall, there was an 18.4% rise in NEAT performance (95% confidence interval (CI): 17.7-19.1) while ED length of stay decreased by a total of 86.8 min (95% CI: 83.6-90.1). Time series analysis did not suggest any preexisting trends to explain these results. The average time to referral decreased by 74.7 min (95% CI: 69.8-79.6) and waiting times decreased across all triage categories. Rates of MERT activation and unplanned representation were unchanged. A facilitated team leader role for senior doctors can help to reduce length of stay by via early disposition, without significant risks to the patient. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Analysis of regional radiotherapy dosimetry audit data and recommendations for future audits
Palmer, A; Mzenda, B; Kearton, J; Wills, R
2011-01-01
Objectives Regional interdepartmental dosimetry audits within the UK provide basic assurances of the dosimetric accuracy of radiotherapy treatments. Methods This work reviews several years of audit results from the South East Central audit group including megavoltage (MV) and kilovoltage (kV) photons, electrons and iodine-125 seeds. Results Apart from some minor systematic errors that were resolved, the results of all audits have been within protocol tolerances, confirming the long-term stability and agreement of basic radiation dosimetric parameters between centres in the audit region. There is some evidence of improvement in radiation dosimetry with the adoption of newer codes of practice. Conclusion The value of current audit methods and the limitations of peer-to-peer auditing is discussed, particularly the influence of the audit schedule on the results obtained, where no “gold standard” exists. Recommendations are made for future audits, including an essential requirement to maintain the monitoring of basic fundamental dosimetry, such as MV photon and electron output, but audits must also be developed to include new treatment technologies such as image-guided radiotherapy and address the most common sources of error in radiotherapy. PMID:21159805
A voxel-based mouse for internal dose calculations using Monte Carlo simulations (MCNP).
Bitar, A; Lisbona, A; Thedrez, P; Sai Maurel, C; Le Forestier, D; Barbet, J; Bardies, M
2007-02-21
Murine models are useful for targeted radiotherapy pre-clinical experiments. These models can help to assess the potential interest of new radiopharmaceuticals. In this study, we developed a voxel-based mouse for dosimetric estimates. A female nude mouse (30 g) was frozen and cut into slices. High-resolution digital photographs were taken directly on the frozen block after each section. Images were segmented manually. Monoenergetic photon or electron sources were simulated using the MCNP4c2 Monte Carlo code for each source organ, in order to give tables of S-factors (in Gy Bq-1 s-1) for all target organs. Results obtained from monoenergetic particles were then used to generate S-factors for several radionuclides of potential interest in targeted radiotherapy. Thirteen source and 25 target regions were considered in this study. For each source region, 16 photon and 16 electron energies were simulated. Absorbed fractions, specific absorbed fractions and S-factors were calculated for 16 radionuclides of interest for targeted radiotherapy. The results obtained generally agree well with data published previously. For electron energies ranging from 0.1 to 2.5 MeV, the self-absorbed fraction varies from 0.98 to 0.376 for the liver, and from 0.89 to 0.04 for the thyroid. Electrons cannot be considered as 'non-penetrating' radiation for energies above 0.5 MeV for mouse organs. This observation can be generalized to radionuclides: for example, the beta self-absorbed fraction for the thyroid was 0.616 for I-131; absorbed fractions for Y-90 for left kidney-to-left kidney and for left kidney-to-spleen were 0.486 and 0.058, respectively. Our voxel-based mouse allowed us to generate a dosimetric database for use in preclinical targeted radiotherapy experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baron-Aznar, C.; Moreno-Jimenez, S.; Celis, M. A.
2008-08-11
Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScan(c) software, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed.
Bibliographic Index of Soviet Military Books, 1960-1969.
1985-10-17
Televideniye v Voyennykh Tselyakh) Moscow, DOSAAF, 1960. 93p. 29000 1r35k. 60-06175 S1511. Middel’dorf, E . Manual on Tactics. (Rukovodstvo Po Taktike) F...Gegeshidze, A. (B)S1307 . Fomin, N. S1655 Gel’fond, G.M. S1500 Fomin, V . S3179 Gel’mert, G. S3209 Fonareva, B.E. S0596 Genkina, D. S1302 . Forverk, E . S1633...S1702 Mordvinov, V . S3100 Mezhelaytlsa, E . S0958 Mordvinov, V.S. S2924, S2946, Middel’dorf, E . S1511 S2968, S3020, S3049, S3050, Mikeladze, M.G. (B)S0984
1951-08-01
and Seques- trene AA at a pH of 5 (with sodium hydroxide). Breeze, one of the agents used, is a commer- cial synthetic detergent com^Pte with addi...9,299] D E I ll s w 1 Ü Mert 12 50 134 47 229 657 68 322 1,110 34 138 335 87 415 1,720 92 442 1,700 69 278 1,180 399...Continued BRA88 (1025) STAINLESS STEEL (38) STAINLESS STEEL (45) .1 IS 5 II .1 OH II IS a 8 S Si Si r it IS a m 8 2 .1 a o
Role of particle radiotherapy in the management of head and neck cancer.
Laramore, George E
2009-05-01
Modern imaging techniques and powerful computers allow a radiation oncologist to design treatments delivering higher doses of radiation than previously possible. Dose distributions imposed by the physics of 'standard' photon and electron beams limit further dose escalation. Hadron radiotherapy offers advantages in either dose distribution and/or improved radiobiology that may significantly improve the treatment of certain head and neck malignancies. Clinical studies support the effectiveness of fast-neutron radiotherapy in the treatment of major and minor salivary gland tumors. Data show highly favorable outcomes with proton radiotherapy for skull-base malignancies and tumors near highly critical normal tissues compared with that expected with standard radiotherapy. Heavy-ion radiotherapy clinical studies are mainly being conducted with fully stripped carbon ions, and limited data seem to indicate a possible improvement over proton radiotherapy for the same subset of radioresistant tumors where neutrons show a benefit over photons. Fast-neutron radiotherapy has different radiobiological properties compared with standard radiotherapy but similar depth dose distributions. Its role in the treatment of head and neck cancer is currently limited to salivary gland malignancies and certain radioresistant tumors such as sarcomas. Protons have the same radiobiological properties as standard radiotherapy beams but more optimal depth dose distributions, making it particularly advantageous when treating tumors adjacent to highly critical structures. Heavy ions combine the radiobiological properties of fast neutrons with the physical dose distributions of protons, and preliminary data indicate their utility for radioresistant tumors adjacent to highly critical structures.
MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zou, W; Swann, B; Siderits, R
2014-06-15
Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carriedmore » out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice.« less
In vivo dosimetry in UK external beam radiotherapy: current and future usage.
MacDougall, Niall D; Graveling, Michael; Hansen, Vibeke N; Brownsword, Kevin; Morgan, Andrew
2017-04-01
Towards Safer Radiotherapy recommended that radiotherapy (RT) centres should have protocols in place for in vivo dosimetry (IVD) monitoring at the beginning of patient treatment courses (Donaldson S. Towards safer radiotherapy. R Coll Radiol 2008). This report determines IVD implementation in the UK in 2014, the methods used and makes recommendations on future use. Evidence from peer-reviewed journals was used in conjunction with the first survey of UK RT centre IVD practice since the publication of Towards Safer Radiotherapy. In March 2014, profession-specific questionnaires were sent to radiographer, clinical oncologist and physics staff groups in each of the 66 UK RT centres. Response rates from each group were 74%, 45% and 74%, respectively. 73% of RT centres indicated that they performed IVD. Diodes are the most popular IVD device. Thermoluminescent dosimeter (TLD) is still in use in a number of centres but not as a sole modality, being used in conjunction with diodes and/or electronic portal imaging device (EPID). The use of EPID dosimetry is increasing and is considered of most potential value for both geometric and dosimetric verification. Owing to technological advances, such as electronic data transfer, independent monitor unit checking and daily image-guided radiotherapy, the overall risk of adverse treatment events in RT has been substantially reduced. However, the use of IVD may prevent a serious radiation incident. Point dose IVD is not considered suited to the requirements of verifying advanced RT techniques, leaving EPID dosimetry as the current modality likely to be developed as a future standard. Advances in knowledge: An updated perspective on UK IVD use and provision of professional guidelines for future implementation.
In vivo dosimetry in UK external beam radiotherapy: current and future usage
Graveling, Michael; Hansen, Vibeke N; Brownsword, Kevin; Morgan, Andrew
2017-01-01
Objective: Towards Safer Radiotherapy recommended that radiotherapy (RT) centres should have protocols in place for in vivo dosimetry (IVD) monitoring at the beginning of patient treatment courses (Donaldson S. Towards safer radiotherapy. R Coll Radiol 2008). This report determines IVD implementation in the UK in 2014, the methods used and makes recommendations on future use. Methods: Evidence from peer-reviewed journals was used in conjunction with the first survey of UK RT centre IVD practice since the publication of Towards Safer Radiotherapy. In March 2014, profession-specific questionnaires were sent to radiographer, clinical oncologist and physics staff groups in each of the 66 UK RT centres. Results: Response rates from each group were 74%, 45% and 74%, respectively. 73% of RT centres indicated that they performed IVD. Diodes are the most popular IVD device. Thermoluminescent dosimeter (TLD) is still in use in a number of centres but not as a sole modality, being used in conjunction with diodes and/or electronic portal imaging device (EPID). The use of EPID dosimetry is increasing and is considered of most potential value for both geometric and dosimetric verification. Conclusion: Owing to technological advances, such as electronic data transfer, independent monitor unit checking and daily image-guided radiotherapy, the overall risk of adverse treatment events in RT has been substantially reduced. However, the use of IVD may prevent a serious radiation incident. Point dose IVD is not considered suited to the requirements of verifying advanced RT techniques, leaving EPID dosimetry as the current modality likely to be developed as a future standard. Advances in knowledge: An updated perspective on UK IVD use and provision of professional guidelines for future implementation. PMID:28205452
A dose optimization method for electron radiotherapy using randomized aperture beams
NASA Astrophysics Data System (ADS)
Engel, Konrad; Gauer, Tobias
2009-09-01
The present paper describes the entire optimization process of creating a radiotherapy treatment plan for advanced electron irradiation. Special emphasis is devoted to the selection of beam incidence angles and beam energies as well as to the choice of appropriate subfields generated by a refined version of intensity segmentation and a novel random aperture approach. The algorithms have been implemented in a stand-alone programme using dose calculations from a commercial treatment planning system. For this study, the treatment planning system Pinnacle from Philips has been used and connected to the optimization programme using an ASCII interface. Dose calculations in Pinnacle were performed by Monte Carlo simulations for a remote-controlled electron multileaf collimator (MLC) from Euromechanics. As a result, treatment plans for breast cancer patients could be significantly improved when using randomly generated aperture beams. The combination of beams generated through segmentation and randomization achieved the best results in terms of target coverage and sparing of critical organs. The treatment plans could be further improved by use of a field reduction algorithm. Without a relevant loss in dose distribution, the total number of MLC fields and monitor units could be reduced by up to 20%. In conclusion, using randomized aperture beams is a promising new approach in radiotherapy and exhibits potential for further improvements in dose optimization through a combination of randomized electron and photon aperture beams.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baeza, J.A.; Ureba, A.; Jimenez-Ortega, E.
Purpose: Although there exist several radiotherapy research platforms, such as: CERR, the most widely used and referenced; SlicerRT, which allows treatment plan comparison from various sources; and MMCTP, a full MCTP system; it is still needed a full MCTP toolset that provides users complete control of calculation grids, interpolation methods and filters in order to “fairly” compare results from different TPSs, supporting verification with experimental measurements. Methods: This work presents CARMEN, a MatLab-based platform including multicore and GPGPU accelerated functions for loading RT data; designing treatment plans; and evaluating dose matrices and experimental data.CARMEN supports anatomic and functional imaging inmore » DICOM format, as well as RTSTRUCT, RTPLAN and RTDOSE. Besides, it contains numerous tools to accomplish the MCTP process, managing egs4phant and phase space files.CARMEN planning mode assist in designing IMRT, VMAT and MERT treatments via both inverse and direct optimization. The evaluation mode contains a comprehensive toolset (e.g. 2D/3D gamma evaluation, difference matrices, profiles, DVH, etc.) to compare datasets from commercial TPS, MC simulations (i.e. 3ddose) and radiochromic film in a user-controlled manner. Results: CARMEN has been validated against commercial RTPs and well-established evaluation tools, showing coherent behavior of its multiple algorithms. Furthermore, CARMEN platform has been used to generate competitive complex treatment that has been published in comparative studies. Conclusion: A new research oriented MCTP platform with a customized validation toolset has been presented. Despite of being coded with a high-level programming language, CARMEN is agile due to the use of parallel algorithms. The wide-spread use of MatLab provides straightforward access to CARMEN’s algorithms to most researchers. Similarly, our platform can benefit from the MatLab community scientific developments as filters, registration algorithms etc. Finally, CARMEN arises the importance of grid and filtering control in treatment plan comparison.« less
WE-G-BRD-09: Novel MRI Compatible Electron Accelerator for MRI-Linac Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whelan, B; Keall, P; Gierman, S
Purpose: MRI guided radiotherapy is a rapidly growing field; however current linacs are not designed to operate in MRI fringe fields. As such, current MRI- Linac systems require magnetic shielding, impairing MR image quality and system flexibility. Here, we present a bespoke electron accelerator concept with robust operation in in-line magnetic fields. Methods: For in-line MRI-Linac systems, electron gun performance is the major constraint on accelerator performance. To overcome this, we propose placing a cathode directly within the first accelerating cavity. Such a configuration is used extensively in high energy particle physics, but not previously for radiotherapy. Benchmarked computational modellingmore » (CST, Darmstadt, Germany) was employed to design and assess a 5.5 cell side coupled accelerator with a temperature limited thermionic cathode in the first accelerating cell. This simulation was coupled to magnetic fields from a 1T MRI model to assess robustness in magnetic fields for Source to Isocenter Distance between 1 and 2 meters. Performance was compared to a conventional electron gun based system in the same magnetic field. Results: A temperature limited cathode (work function 1.8eV, temperature 1245K, emission constant 60A/K/cm{sup 2}) will emit a mean current density of 24mA/mm{sup 2} (Richardson’s Law). We modeled a circular cathode with radius 2mm and mean current 300mA. Capture efficiency of the device was 43%, resulting in target current of 130 mA. The electron beam had a FWHM of 0.2mm, and mean energy of 5.9MeV (interquartile spread of 0.1MeV). Such an electron beam is suitable for radiotherapy, comparing favourably to conventional systems. This model was robust to operation the MRI fringe field, with a maximum current loss of 6% compared to 85% for the conventional system. Conclusion: The bespoke electron accelerator is robust to operation in in-line magnetic fields. This will enable MRI-Linacs with no accelerator magnetic shielding, and minimise painstaking optimisation of the MRI fringe field. This work was supported by US (NIH) and Australian (NHMRC & Cancer Institute NSW) government research funding. In addition, I would like to thank cancer institute NSW and the Ingham Institute for scholarship support.« less
SU-E-T-25: Real Time Simulator for Designing Electron Dual Scattering Foil Systems.
Carver, R; Hogstrom, K; Price, M; Leblanc, J; Harris, G
2012-06-01
To create a user friendly, accurate, real time computer simulator to facilitate the design of dual foil scattering systems for electron beams on radiotherapy accelerators. The simulator should allow for a relatively quick, initial design that can be refined and verified with subsequent Monte Carlo (MC) calculations and measurements. The simulator consists of an analytical algorithm for calculating electron fluence and a graphical user interface (GUI) C++ program. The algorithm predicts electron fluence using Fermi-Eyges multiple Coulomb scattering theory with a refined Moliere formalism for scattering powers. The simulator also estimates central-axis x-ray dose contamination from the dual foil system. Once the geometry of the beamline is specified, the simulator allows the user to continuously vary primary scattering foil material and thickness, secondary scattering foil material and Gaussian shape (thickness and sigma), and beam energy. The beam profile and x-ray contamination are displayed in real time. The simulator was tuned by comparison of off-axis electron fluence profiles with those calculated using EGSnrc MC. Over the energy range 7-20 MeV and using present foils on the Elekta radiotherapy accelerator, the simulator profiles agreed to within 2% of MC profiles from within 20 cm of the central axis. The x-ray contamination predictions matched measured data to within 0.6%. The calculation time was approximately 100 ms using a single processor, which allows for real-time variation of foil parameters using sliding bars. A real time dual scattering foil system simulator has been developed. The tool has been useful in a project to redesign an electron dual scattering foil system for one of our radiotherapy accelerators. The simulator has also been useful as an instructional tool for our medical physics graduate students. © 2012 American Association of Physicists in Medicine.
Full Geant4 and FLUKA simulations of an e-LINAC for its use in particle detectors performance tests
NASA Astrophysics Data System (ADS)
Alpat, B.; Pilicer, E.; Servoli, L.; Menichelli, M.; Tucceri, P.; Italiani, M.; Buono, E.; Di Capua, F.
2012-03-01
In this work we present the results of full Geant4 and FLUKA simulations and comparison with dosimetry data of an electron LINAC of St. Maria Hospital located in Terni, Italy. The facility is being used primarily for radiotherapy and the goal of the present study is the detailed investigation of electron beam parameters to evaluate the possibility to use the e-LINAC (during time slots when it is not used for radiotherapy) to test the performance of detector systems, in particular those designed to operate in space. The critical beam parameters are electron energy, profile and flux available at the surface of device to be tested. The present work aims to extract these parameters from dosimetry calibration data available at the e-LINAC. The electron energy ranges from 4 MeV to 20 MeV. The dose measurements have been performed by using an Advanced Markus Chamber which has a small sensitive volume.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hickling, S; El Naqa, I
Purpose: Previous work has demonstrated the detectability of acoustic waves induced following the irradiation of high density metals with radiotherapy linac photon beams. This work demonstrates the ability to experimentally detect such acoustic signals following both photon and electron irradiation in a more radiotherapy relevant material. The relationship between induced acoustic signal properties in water and the deposited dose distribution is explored, and the feasibility of exploiting such signals for radiotherapy dosimetry is demonstrated. Methods: Acoustic waves were experimentally induced in a water tank via the thermoacoustic effect following a single pulse of photon or electron irradiation produced by amore » clinical linac. An immersion ultrasound transducer was used to detect these acoustic waves in water and signals were read out on an oscilloscope. Results: Peaks and troughs in the detected acoustic signals were found to correspond to the location of gradients in the deposited dose distribution following both photon and electron irradiation. Signal amplitude was linearly related to the dose per pulse deposited by photon or electron beams at the depth of detection. Flattening filter free beams induced large acoustic signals, and signal amplitude decreased with depth after the depth of maximum dose. Varying the field size resulted in a temporal shift of the acoustic signal peaks and a change in the detected signal frequency. Conclusion: Acoustic waves can be detected in a water tank following irradiation by linac photon and electron beams with basic electronics, and have characteristics related to the deposited dose distribution. The physical location of dose gradients and the amount of dose deposited can be inferred from the location and magnitude of acoustic signal peaks. Thus, the detection of induced acoustic waves could be applied to photon and electron water tank and in vivo dosimetry. This work was supported in part by CIHR grants MOP-114910 and MOP-136774. S.H. acknowledges support by the NSERC CREATE Medical Physics Research Training Network grant 432290.« less
Schaeken, B; Cuypers, R; Lelie, S; Schroeyers, W; Schreurs, S; Janssens, H; Verellen, D
2011-04-01
A measurement procedure based on alanine/electron paramagnetic resonance (EPR) dosimetry was implemented successfully providing simple, stable, and accurate dose-to-water (D(w)) measurements. The correspondence between alanine and ionization chamber measurements in reference conditions was excellent. Alanine/EMR dosimetry might be a valuable alternative to thermoluminescent (TLD) and ionization chamber based measuring procedures in radiotherapy audits. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Madrid, Cristhian C; de Pauli Paglioni, Mariana; Line, Sergio R; Vasconcelos, Karina G; Brandão, Thaís Bianca; Lopes, Marcio A; Santos-Silva, Alan Roger; De Goes, Mario Fernando
2017-01-01
To analyze macroscopic, microscopic, and ultrastructural aspects of enamel from head-and-neck cancer patients submitted to radiotherapy. Twenty sound extracted permanent molars were used and divided into 2 groups. The experimental group consisted of 10 molars from head-and-neck cancer patients submitted to radiotherapy with total doses that ranged from 50 to 70 Gy. Ten molars from patients who did not receive radiotherapy were matched with experimental-group samples by anatomic tooth group and comprised the control group. To perform a macroscopic analysis, standardized photos of different enamel faces were taken with a camera. Teeth were subjected to longitudinal cuts and hand polished to a final thickness of 0.1 mm. Enamel was analyzed under polarized light microscopy, and optical retardation values of birefringence were calculated in cervical, cusp, and occlusal pit areas. Subsequently, the same enamel areas were analyzed by scanning electron microscopy. Data from optical retardation values were statistically analyzed by 2-way ANOVA and Fisher's test (α < 0.05). No macroscopic differences were observed between the irradiated and control groups. Polarized light microscopy analysis revealed that cervical enamel exhibited darker areas characterized by discrete birefringence patterns compared to the control enamel. Optical retardation values were only significantly different in the cervical enamel of the irradiated and control groups (p < 0.0001). Scanning electron microscopy analysis revealed more evident interprismatic spaces in the cervical and outer cusp enamel of irradiated samples. Head-and-neck radiotherapy reduced optical retardation values of birefringence in cervical enamel, and the interprismatic spaces became more evident. © 2017 S. Karger AG, Basel.
Piermattei, Angelo; Kang, Shengwei; Xiao, Mingyong; Tang, Bin; Liao, Xiongfei; Xin, Xin; Grusio, Mattia
2018-01-01
High conformal techniques such as intensity-modulated radiation therapy and volumetric-modulated arc therapy are widely used in overloaded radiotherapy departments. In vivo dosimetric screening is essential in this environment to avoid important dosimetric errors. This work examines the feasibility of introducing in vivo dosimetry (IVD) checks in a radiotherapy routine. The causes of dosimetric disagreements between delivered and planned treatments were identified and corrected during the course of treatment. The efficiency of the corrections performed and the added workload needed for the entire procedure were evaluated. The IVD procedure was based on an electronic portal imaging device. A total of 3682 IVD tests were performed for 147 patients who underwent head and neck, abdomen, pelvis, breast, and thorax radiotherapy treatments. Two types of indices were evaluated and used to determine if the IVD tests were within tolerance levels: the ratio R between the reconstructed and planned isocentre doses and a transit dosimetry based on the γ-analysis of the electronic portal images. The causes of test outside tolerance level were investigated and corrected and IVD test was repeated during subsequent fraction. The time needed for each step of the IVD procedure was registered. Pelvis, abdomen, and head and neck treatments had 10% of tests out of tolerance whereas breast and thorax treatments accounted for up to 25%. The patient setup was the main cause of 90% of the IVD tests out of tolerance and the remaining 10% was due to patient morphological changes. An average time of 42 min per day was sufficient to monitor a daily workload of 60 patients in treatment. This work shows that IVD performed with an electronic portal imaging device is feasible in an overloaded department and enables the timely realignment of the treatment quality indices in order to achieve a patient’s final treatment compliant with the one prescribed. PMID:29432473
SU-E-T-238: Monte Carlo Estimation of Cerenkov Dose for Photo-Dynamic Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chibani, O; Price, R; Ma, C
Purpose: Estimation of Cerenkov dose from high-energy megavoltage photon and electron beams in tissue and its impact on the radiosensitization using Protoporphyrine IX (PpIX) for tumor targeting enhancement in radiotherapy. Methods: The GEPTS Monte Carlo code is used to generate dose distributions from 18MV Varian photon beam and generic high-energy (45-MV) photon and (45-MeV) electron beams in a voxel-based tissueequivalent phantom. In addition to calculating the ionization dose, the code scores Cerenkov energy released in the wavelength range 375–425 nm corresponding to the pick of the PpIX absorption spectrum (Fig. 1) using the Frank-Tamm formula. Results: The simulations shows thatmore » the produced Cerenkov dose suitable for activating PpIX is 4000 to 5500 times lower than the overall radiation dose for all considered beams (18MV, 45 MV and 45 MeV). These results were contradictory to the recent experimental studies by Axelsson et al. (Med. Phys. 38 (2011) p 4127), where Cerenkov dose was reported to be only two orders of magnitude lower than the radiation dose. Note that our simulation results can be corroborated by a simple model where the Frank and Tamm formula is applied for electrons with 2 MeV/cm stopping power generating Cerenkov photons in the 375–425 nm range and assuming these photons have less than 1mm penetration in tissue. Conclusion: The Cerenkov dose generated by high-energy photon and electron beams may produce minimal clinical effect in comparison with the photon fluence (or dose) commonly used for photo-dynamic therapy. At the present time, it is unclear whether Cerenkov radiation is a significant contributor to the recently observed tumor regression for patients receiving radiotherapy and PpIX versus patients receiving radiotherapy only. The ongoing study will include animal experimentation and investigation of dose rate effects on PpIX response.« less
The 1998 Australian external beam radiotherapy survey and IAEA/WHO TLD postal dose quality audit.
Huntley, R; Izewska, J
2000-03-01
The results of an updated Australian survey of external beam radiotherapy centres are presented. Most of the centres provided most of the requested information. The relative caseloads of various linear accelerator photon and electron beams have not changed significantly since the previous survey in 1995. The mean age of Australian LINACs is 7.1 years and that of other radiotherapy machines is 14.7 years. Every Australian radiotherapy centre participated in a special run of the IAEA/WHO TLD postal dose quality audit program, which was provided for Australian centres by the IAEA and WHO in May 1998. The dose quoted by the centres was in nearly every case within 1.5% of the dose assessed by the IAEA. This is within the combined standard uncertainty of the IAEA TLD service (1.8%). The results confirm the accuracy and precision of radiotherapy dosimetry in Australia and the adequate dissemination of the Australian standards from ARL (now ARPANSA) to the centres. The Australian standards have recently been shown to agree with those of other countries to within 0.25% by comparison with the BIPM.
Yang, Min; Ma, Bo; Shao, Hanshuang; Clark, Amanda M; Wells, Alan
2016-07-07
Metastatic progression of breast cancer involves phenotypic plasticity of the carcinoma cells moving between epithelial and mesenchymal behaviors. During metastatic seeding and dormancy, even highly aggressive carcinoma cells take on an E-cadherin-positive epithelial phenotype that is absent from the emergent, lethal metastatic outgrowths. These phenotypes are linked to the metastatic microenvironment, though the specific cells and induction signals are still to be deciphered. Recent evidence suggests that macrophages impact tumor progression, and may alter the balance between cancer cell EMT and MErT in the metastatic microenvironment. Here we explore the role of M1/M2 macrophages in epithelial-mesenchymal plasticity of breast cancer cells by coculturing epithelial and mesenchymal cells lines with macrophages. We found that after polarizing the THP-1 human monocyte cell line, the M1 and M2-types were stable and maintained when co-cultured with breast cancer cells. Surprisingly, M2 macrophages may conferred a growth advantage to the epithelial MCF-7 cells, with these cells being driven to a partial mesenchymal phenotypic as indicated by spindle morphology. Notably, E-cadherin protein expression is significantly decreased in MCF-7 cells co-cultured with M2 macrophages. M0 and M1 macrophages had no effect on the MCF-7 epithelial phenotype. However, the M1 macrophages impacted the highly aggressive mesenchymal-like MDA-MB-231 breast cancer cells to take on a quiescent, epithelial phenotype with re-expression of E-cadherin. The M2 macrophages if anything exacerbated the mesenchymal phenotype of the MDA-MB-231 cells. Our findings demonstrate M2 macrophages might impart outgrowth and M1 macrophages may contribute to dormancy behaviors in metastatic breast cancer cells. Thus EMT and MErT are regulated by selected macrophage phenotype in the liver metastatic microenvironment. These results indicate macrophage could be a potential therapeutic target for limiting death due to malignant metastases in breast cancer.
Guenzi, Marina; Bonzano, Elisabetta; Corvò, Renzo; Merolla, Francesca; Pastorino, Alice; Cavagnetto, Francesca; Garelli, Stefania; Cutolo, Carlo Alberto; Friedman, Daniele; Belgioia, Liliana
2018-01-01
To evaluate local recurrence (LR) in women with early breast cancer (BC) who underwent intraoperative radiation therapy with electrons particles (IORT-E) or adjuvant hypofractionated external radiotherapy (HYPOFX). We retrospectively analyzed 470 patients with early BC treated at our center from September 2009 to December 2012. 235 women were treated with breast-conserving surgery and immediate IORT-E (21 Gy/1 fraction) while 235 patients underwent wide excision followed by hypofractionated whole-breast irradiation. Radiotherapy modality was chosen according to an individualized decision based on tumor features, stage, technical feasibility, age, and acceptance to be enrolled in the IORT-E group. After a median follow-up of 6 years, we observed 8 (3.4%) and 1 (0.42%) LR in the IORT-E and in the HYPOFX group ( p = 0.02), respectively. The two groups differed in the prevalence of clinical characteristics ( p < 0.05): age, tumor size, surgical margins, receptors, ki67, and histology. 4 and 1 woman in the IORT-E and HYPOFX group died of BC, respectively ( p = 0.167). OS and DFS hazard ratio [HR] were 2.14 (95% IC, 1.10-4.15) and 2.09 (95% IC, 1.17-3.73), respectively. Our comparison showed that IORT-E and HYPOFX are two effective radiotherapy modalities after conservative surgery in early BC. However, at 6 years a significant higher rate of LR occurred in patients submitted to IORT-E with respect to HYPOFX. This finding may be correlated to some subsets of patients who, depending on the biological characteristics of the BC, may be less suitable to IORT-E.
Irreversible electron attachment--a key to DNA damage by solvated electrons in aqueous solution.
Westphal, K; Wiczk, J; Miloch, J; Kciuk, G; Bobrowski, K; Rak, J
2015-11-07
The TYT and TXT trimeric oligonucleotides, where X stands for a native nucleobase, T (thymine), C (cytosine), A (adenine), or G (guanine), and Y indicates a brominated analogue of the former, were irradiated with ionizing radiation generated by a (60)Co source in aqueous solutions containing Tris as a hydroxyl radical scavenger. In the past, these oligomers were bombarded with low energy electrons under an ultra-high vacuum and significant damage to TXT trimers was observed. However, in aqueous solution, hydrated electrons do not produce serious damage to TXT trimers although the employed radiation dose exceeded many times the doses used in radiotherapy. Thus, our studies demonstrate unequivocally that hydrated electrons, which are the major form of electrons generated during radiotherapy, are a negligible factor in damage to native DNA. It was also demonstrated that all the studied brominated nucleobases have a potential to sensitize DNA under hypoxic conditions. Strand breaks, abasic sites and the products of hydroxyl radical attachment to nucleobases have been identified by HPLC and LC-MS methods. Although all the bromonucleobases lead to DNA damage under the experimental conditions of the present work, bromopyrimidines seem to be the radiosensitizers of choice since they lead to more strand breaks than bromopurines.
Allgower, C E; Schreuder, A N; Farr, J B; Mascia, A E
2007-03-01
Protons beams deliver targeted radiation doses with greater precision than is possible with electrons or megavoltage X-ray photons, but to retain this advantage, patient positioning systems at proton clinics must meet tighter accuracy requirements. For this and other reasons, robots were incorporated into the treatment room systems at MPRI. The Midwest Proton Radiotherapy Institute (MPRI) is the first radiotherapy facility in the United States to use commercial robots with six degrees of freedom for patient positioning, rather than a traditional bed with four degrees of freedom. This paper outlines the ways in which robots are used at MPRI and attempts to distil insights from the experience of treating over 200 radiotherapy patients with a robotic system from February 2004 to late 2006. The system has performed well, and with great reliability, but there is room for future improvement, especially in ease of use and in reducing the time to get patients into position. Copyright 2006 John Wiley & Sons, Ltd.
Carl, Jesper; Lund, Bente; Larsen, Erik Hoejkjaer; Nielsen, Jane
2006-02-01
A new method for localization of the prostate during external beam radiotherapy is presented. The method is based on insertion of a thermo-expandable Ni-Ti stent. The stent is originally developed for treatment of bladder outlet obstruction caused by benign hyperplasia. The radiological properties of the stent are used for precise prostate localization during treatment using electronic portal images. Patients referred for intended curative radiotherapy and having a length of their prostatic urethra in the range from 25 to 65 mm were included. Pairs of isocentric orthogonal portal images were used to determine the 3D position at eight different treatment sessions for each patient. Fourteen patients were enrolled in the study. The data obtained demonstrated that the stent position was representative of the prostate location. The stent may also improve delineation of the prostate GTV, and prevent obstruction of bladder outlet during treatment. Precision in localization of the stent was less than 1 mm. Random errors in stent position were left-right 1.6 mm, cranial-caudal 2.2 mm and anterior-posterior 3.2 mm. In four of 14 patients a dislocation of the stent to the bladder occurred. Dislocation only occurred in patients with length of prostatic urethra less than 40 mm. A new method for radiological high precision localization of the prostate during radiotherapy is presented. The method is based on insertion of a standard Ni-Ti thermo-expandable stent, designed for treatment of benign prostate hyperplasia.
Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses.
Love, P A; Lewis, D G; Al-Affan, I A; Smith, C W
1998-05-01
The Monte Carlo codes EGS4 and MCNP have been compared when calculating radiotherapy depth doses in water. The aims of the work were to study (i) the differences between calculated depth doses in water for a range of monoenergetic photon energies and (ii) the relative efficiency of the two codes for different electron transport energy cut-offs. The depth doses from the two codes agree with each other within the statistical uncertainties of the calculations (1-2%). The relative depth doses also agree with data tabulated in the British Journal of Radiology Supplement 25. A discrepancy in the dose build-up region may by attributed to the different electron transport algorithims used by EGS4 and MCNP. This discrepancy is considerably reduced when the improved electron transport routines are used in the latest (4B) version of MCNP. Timing calculations show that EGS4 is at least 50% faster than MCNP for the geometries used in the simulations.
Energy response of glass bead TLDs irradiated with radiation therapy beams
NASA Astrophysics Data System (ADS)
Jafari, S. M.; Jordan, T. J.; Hussein, M.; Bradley, D. A.; Clark, C. H.; Nisbet, A.; Spyrou, N. M.
2014-11-01
Glass beads are a novel TL dosimeter in radiotherapy. An important characteristic of TL dosimeters is their energy response, especially when intended for use in radiotherapy applications over a wide range of energies (typically from X-rays generated at 80 kVp up to 25 MV photon and MeV electron beams). In this paper, the energy response of glass beads (Mill Hill, Japan) is investigated for their TL response to kV X-rays from an orthovoltage radiotherapy unit and also for MV photon and MeV electron beams from a medical linear accelerator. The experimental findings show that for photon and electron beams, the TL response of this particular glass bead, normalised to unity for 6 MV X-rays (TPR20/10=0.670), decreases to 0.96±0.02 for 15 MV X-rays (TPR20/10=0.761) and to 0.95±0.01 for 20 MeV electron beams (R50,D=8.35 cm). This compares favourably with other TLD materials such as LiF and also alanine dosimeters that are readout with an EPR system. For kV X-rays, the response increases to 4.52±0.05 for 80 kV X-rays (HVL=2.4 mm Al) which approaches 3 times that of LiF TLDs and 5 times that of alanine. In conclusion, the particular glass beads, when used as a dosimeter material, show a relatively small energy dependence over the megavoltage range of clinically relevant radiation qualities, being clearly advantageous for accurate dosimetry. Conversely, the energy response is significant for photon beam energies covering the kV range. In both circumstances, in dosimetric evaluations the energy response needs to be taken into account.
Low-Energy Electrons Emitted in Ion Collisions with Thin Foils
NASA Astrophysics Data System (ADS)
Kraemer, Michael; Kozhuharov, Christophor; Durante, Marco; Hagmann, Siegbert; Kraft, Gerhard; Lineva, Natallia
The realistic description of radiation damage after charged particle passage is an ongoing issue for both radiotherapy as well as space applications. In both areas of applied radiological science, living as well as nonliving matter is exposed to ionizing radiation, and it is of vital interest to predict the responses of structures like cells, detectors or electronic devices. In ion beam radiotherapy, for example, the Local Effect Model (LEM) is being used to calculate radiobiological effects with so far unprecedented versatility. This has been shown in the GSI radiotherapy pilot project and consequently this model has become the "industry standard" for treatment planning in subsequent commercial ion radiotherapy sites. The model has also been extended to nonliving matter, i.e. to describe the response of solid state detectors such as TLDs and films. A prerequisite for this model (and possibly similar ones) is the proper description of microscopic track structure and energy deposition. In particular, the area at a very low distance (¡20 nm) from the ion path needs special attention due to the locally very high dose and the rather limited experimental evidence for the shape of the dose distribution. The dose distribution at low distances is inevitably associated with the creation and transport of low-energy (sub-keV) electrons. While some data, elementary cross sections as well as dose distributions, exist for gaseous media, i.e. under single collision conditions, experimental data for the condensed phase are scarce. We have, therefore, launched a project aimed at systematic research of the energy and angular distributions of low-energy (sub-keV) electrons emitted from solids. These investigations com-prise creation as well as transport of low-energy electrons under multiple collision conditions and hence require accounting for the properties of the target, both bulk and surface, i.e. for the inherent inhomogeneity of the thickness and for the surface roughness. To this end, electron spectra were measured from collisions of 3.6 and 11.4 MeV/u carbon ions impinging on thin (4 to 40ug/cm**2) C, Ni, Ag, and Au targets. The results were compared with simple conventional theories as well as with dedicated TRAX Monte Carlo simulations taking transport through the material into account. We will discuss the importance of the projectile electrons as well as the instantaneous charge state of the projectile within the target material. These investigations were complemented with protons in comparison with singly charged H3 molecules as projectiles. The fact that the ratio of the cross sections for electron production is not unity and slightly increases with the electron energy supports the emphasis that we put on the importance of the projectile electrons and on the knowledge of the instantaneous charge state. The spectra further exhibit two structures that belong to the KLL-Auger lines of carbon and oxygen. The C-line originates from the target surface and from the adsorbed carbon; the O-line originates entirely from the adsorbed oxygen molecules. It appears that the line structure can be explained by the back-diffusion of the Auger electrons.
NASA Astrophysics Data System (ADS)
Jechel, Christopher Alexander
In radiotherapy planning, computed tomography (CT) images are used to quantify the electron density of tissues and provide spatial anatomical information. Treatment planning systems use these data to calculate the expected spatial distribution of absorbed dose in a patient. CT imaging is complicated by the presence of metal implants which cause increased image noise, produce artifacts throughout the image and can exceed the available range of CT number values within the implant, perturbing electron density estimates in the image. Furthermore, current dose calculation algorithms do not accurately model radiation transport at metal-tissue interfaces. Combined, these issues adversely affect the accuracy of dose calculations in the vicinity of metal implants. As the number of patients with orthopedic and dental implants grows, so does the need to deliver safe and effective radiotherapy treatments in the presence of implants. The Medical Physics group at the Cancer Centre of Southeastern Ontario and Queen's University has developed a Cobalt-60 CT system that is relatively insensitive to metal artifacts due to the high energy, nearly monoenergetic Cobalt-60 photon beam. Kilovoltage CT (kVCT) images, including images corrected using a commercial metal artifact reduction tool, were compared to Cobalt-60 CT images throughout the treatment planning process, from initial imaging through to dose calculation. An effective metal artifact reduction algorithm was also implemented for the Cobalt-60 CT system. Electron density maps derived from the same kVCT and Cobalt-60 CT images indicated the impact of image artifacts on estimates of photon attenuation for treatment planning applications. Measurements showed that truncation of CT number data in kVCT images produced significant mischaracterization of the electron density of metals. Dose measurements downstream of metal inserts in a water phantom were compared to dose data calculated using CT images from kVCT and Cobalt-60 systems with and without artifact correction. The superior accuracy of electron density data derived from Cobalt-60 images compared to kVCT images produced calculated dose with far better agreement with measured results. These results indicated that dose calculation errors from metal image artifacts are primarily due to misrepresentation of electron density within metals rather than artifacts surrounding the implants.
External audits of electron beams using mailed TLD dosimetry: preliminary results.
Gomola, I; Van Dam, J; Isern-Verdum, J; Verstraete, J; Reymen, R; Dutreix, A; Davis, B; Huyskens, D
2001-02-01
A feasibility study has been performed to investigate the possibility of using mailed thermoluminescence dosimetry (TLD) for external audits of clinical electron beams in Europe. In the frame of the EC Network Project for Quality Assurance in Radiotherapy, instruction sheets and mailing procedures have been defined for mailed TLD dosimetry using the dedicated holder developed by a panel of experts of the International Atomic Energy Agency (IAEA). Three hundred and thirty electron beam set-ups have been checked in the reference centres and some local centres of the EC Network Project and in addition through the centres participating to the EORTC Radiotherapy Group trial 22922. The mean ratio of measured dose to stated dose is 0.2% and the standard deviation of measured dose to stated dose is 3.2%. In seven beam set-ups, deviations greater than 10% were observed (max. 66%), showing the usefulness of these checks. The results of this feasibility study (instruction sheets, mailing procedures, holder) are presently endorsed by the EQUAL-ESTRO structure in order to offer in the future to all ESTRO members the possibility to request external audits of clinical electron beams.
NASA Astrophysics Data System (ADS)
Shih, Tian-Yu; Yen, Tsung-Hsien; Liu, Yan-Lin; Luzhbin, Dmytro; Wu, Jay
2017-11-01
The advantage of electron beam radiotherapy is that the absorbed dose rapidly decreases with the increasing depth, which can prevent damage to deeper organs and tissues. Accurately evaluating the absorbed dose in the superficial tumor is imperative. This study assessed the characteristics of electron beams by using the N-isopropyl-acrylamide (n-NIPAM) gel dosimeter. The n-NIPAM gel was composed of 6% gelatin, 5% monomer, and 2.5% cross-linker with 5 mM tetrakis (hydroxymethyl) phosphonium chloride for deoxygenation. The gel was irradiated with 6-, 9-, and 12-MeV electron beams with dose rates of 100-600 MU/min, respectively. The energy dependence and dose rate dependence were assessed. The beam profiles and percentage depth doses were measured and compared with the results of the Gafchromic film and ionization chamber. The linearity of the n-NIPAM gel under 6-, 9-, and 12-MeV electrons was larger than 0.990 with 2% variation in sensitivity. The sensitivity of the gel under 100-600 MU/min showed 5% variations. The energy and dose rate dependence can be negligible. The beam profiles and percentage depth doses measured by the n-NIPAM gel matched well with the results of the ionization chamber and film. This study reveals the possibility of using the n-NIPAM gel dosimeter for electron beam measurements in clinical radiotherapy.
Meesat, Ridthee; Belmouaddine, Hakim; Allard, Jean-François; Tanguay-Renaud, Catherine; Lemay, Rosalie; Brastaviceanu, Tiberius; Tremblay, Luc; Paquette, Benoit; Wagner, J Richard; Jay-Gerin, Jean-Paul; Lepage, Martin; Huels, Michael A; Houde, Daniel
2012-09-18
Since the invention of cancer radiotherapy, its primary goal has been to maximize lethal radiation doses to the tumor volume while keeping the dose to surrounding healthy tissues at zero. Sadly, conventional radiation sources (γ or X rays, electrons) used for decades, including multiple or modulated beams, inevitably deposit the majority of their dose in front or behind the tumor, thus damaging healthy tissue and causing secondary cancers years after treatment. Even the most recent pioneering advances in costly proton or carbon ion therapies can not completely avoid dose buildup in front of the tumor volume. Here we show that this ultimate goal of radiotherapy is yet within our reach: Using intense ultra-short infrared laser pulses we can now deposit a very large energy dose at unprecedented microscopic dose rates (up to 10(11) Gy/s) deep inside an adjustable, well-controlled macroscopic volume, without any dose deposit in front or behind the target volume. Our infrared laser pulses produce high density avalanches of low energy electrons via laser filamentation, a phenomenon that results in a spatial energy density and temporal dose rate that both exceed by orders of magnitude any values previously reported even for the most intense clinical radiotherapy systems. Moreover, we show that (i) the type of final damage and its mechanisms in aqueous media, at the molecular and biomolecular level, is comparable to that of conventional ionizing radiation, and (ii) at the tumor tissue level in an animal cancer model, the laser irradiation method shows clear therapeutic benefits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rotstein, S.; Lax, I.; Svane, G.
1990-01-01
The relative electron density of lung tissue was measured from computer tomography (CT) slices in 33 breast cancer patients treated by various techniques of adjuvant radiotherapy. The measurements were made before radiotherapy, 3 months and 9 months after completion of radiation therapy. The changes in lung densities at 3 months and 9 months were compared to radiation induced radiological (CT) findings. In addition, subjective symptoms such as cough and dyspnoea were assessed before and after radiotherapy. It was observed that the mean of the relative electron density of lung tissue varied from 0.25 when the whole lung was considered tomore » 0.17 when only the anterior lateral quarter of the lung was taken into account. In patients with positive radiological (CT) findings the mean lung density of the anterior lateral quarter increased 2.1 times 3 months after radiotherapy and was still increased 1.6 times 6 months later. For those patients without findings, in the CT pictures the corresponding values were 1.2 and 1.1, respectively. The standard deviation of the pixel values within the anterior lateral quarter of the lung increased 3.8 times and 3.2 times at 3 months and 9 months, respectively, in the former group, as opposed to 1.2 and 1.1 in the latter group. Thirteen patients had an increase in either cough or dyspnoea as observed 3 months after completion of radiotherapy. In eleven patients these symptoms persisted 6 months later. No significant correlation was found between radiological findings and subjective symptoms. However, when three different treatment techniques were compared among 29 patients the highest rate of radiological findings was observed in patients in which the largest lung volumes received the target dose. A tendency towards an increased rate of subjective symptoms was also found in this group.« less
Norrgård, F S; Sipilä, P M; Kulmala, J A; Minn, H R
1998-06-01
Dose characteristics of a stereotactic radiotherapy unit based on a standard Varian Clinac 4/100 4 MV linear accelerator, in-house-built Lipowitz collimators and the SMART stereotactic radiotherapy treatment planning software have been determined. Beam collimation is constituted from the standard collimators of the linear accelerator and a tertiary collimation consisting of a replaceable divergent Lipowitz collimator. Four collimators with isocentre diameters of 15, 25, 35 and 45 mm, respectively, were constructed. Beam characteristics were measured in air, acrylic or water with ionization chamber, photon diode, electron diode, diamond detector and film. Monte Carlo simulation was also applied. The radiation leakage under the collimators was less than 1% at 50 mm depth in water. Specific beam characteristics for each collimator were imported to SMART and dose planning with five non-coplanar converging 140 degrees arcs separated by 36 degrees angles was performed for treatment of a RANDO phantom. Dose verification was made with TLD and radiochromic film. The in-house-built collimators were found to be suitable for stereotactic radiotherapy and patient treatments with this system are in progress.
Electronic brachytherapy—current status and future directions
2015-01-01
In the past decade, electronic brachytherapy (EB) has emerged as an attractive modality for the treatment of skin lesions and intraoperative partial breast irradiation, as well as finding wider applications in intracavitary and interstitial sites. These miniature X-ray sources, which operate at low kilovoltage energies (<100 kV), have reduced shielding requirements and inherent portability, therefore can be used outside the traditional realms of the radiotherapy department. However, steep dose gradients and increased sensitivity to inhomogeneities challenge accurate dosimetry. Secondly, ease of use does not mitigate the need for close involvement by medical physics experts and consultant oncologists. Finally, further studies are needed to relate the more heterogeneous dose distributions to clinical outcomes. With these provisos, the practical convenience of EB strongly suggests that it will become an established option for selected patients, not only in radiotherapy departments but also in a range of operating theatres and clinics around the world. PMID:25748070
A neutron track etch detector for electron linear accelerators in radiotherapy
Vukovic, Branko; Faj, Dario; Poje, Marina; Varga, Maja; Radolic, Vanja; Miklavcic, Igor; Ivkovic, Ana; Planinic, Josip
2010-01-01
Background Electron linear accelerators in medical radiotherapy have replaced cobalt and caesium sources of radiation. However, medical accelerators with photon energies over 10 MeV generate undesired fast neutron contamination in a therapeutic X-ray photon beam. Photons with energies above 10 MeV can interact with the atomic nucleus of a high-Z material, of which the target and the head of an accelerator consist, and lead to the neutron ejection. Results and conclusions. Our neutron dosimeter, composed of the LR-115 track etch detector and boron foil BN-1 converter, was calibrated on thermal neutrons generated in the nuclear reactor of the Josef Stefan Institute (Slovenia), and applied to dosimetry of undesirable neutrons in photon radiotherapy by the linear accelerator 15 MV Siemens Mevatron. Having considered a high dependence of a cross-section between neutron and boron on neutron energy, and broad neutron spectrum in a photon beam, as well as outside the entrance door to maze of the Mevatron, we developed a method for determining the effective neutron detector response. A neutron dose rate in the photon beam was measured to be 1.96 Sv/h. Outside the Mevatron room the neutron dose rate was 0.62 μSv/h. PACS: 87.52. Ga; 87.53.St; 29.40.Wk. PMID:22933893
An implementation of discrete electron transport models for gold in the Geant4 simulation toolkit
NASA Astrophysics Data System (ADS)
Sakata, D.; Incerti, S.; Bordage, M. C.; Lampe, N.; Okada, S.; Emfietzoglou, D.; Kyriakou, I.; Murakami, K.; Sasaki, T.; Tran, H.; Guatelli, S.; Ivantchenko, V. N.
2016-12-01
Gold nanoparticle (GNP) boosted radiation therapy can enhance the biological effectiveness of radiation treatments by increasing the quantity of direct and indirect radiation-induced cellular damage. As the physical effects of GNP boosted radiotherapy occur across energy scales that descend down to 10 eV, Monte Carlo simulations require discrete physics models down to these very low energies in order to avoid underestimating the absorbed dose and secondary particle generation. Discrete physics models for electron transportation down to 10 eV have been implemented within the Geant4-DNA low energy extension of Geant4. Such models allow the investigation of GNP effects at the nanoscale. At low energies, the new models have better agreement with experimental data on the backscattering coefficient, and they show similar performance for transmission coefficient data as the Livermore and Penelope models already implemented in Geant4. These new models are applicable in simulations focussed towards estimating the relative biological effectiveness of radiation in GNP boosted radiotherapy applications with photon and electron radiation sources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kinsella, T.J.; DeLuca, A.M.; Barnes, M.
1991-04-01
Radiation injury to peripheral nerve is a dose-limiting toxicity in the clinical application of intraoperative radiotherapy, particularly for pelvic and retroperitoneal tumors. Intraoperative radiotherapy-related peripheral neuropathy in humans receiving doses of 20-25 Gy is manifested as a mixed motor-sensory deficit beginning 6-9 months following treatment. In a previous experimental study of intraoperative radiotherapy-related neuropathy of the lumbro-sacral plexus, an approximate inverse linear relationship was reported between the intraoperative dose (20-75 Gy range) and the time to onset of hind limb paresis (1-12 mos following intraoperative radiotherapy). The principal histological lesion in irradiated nerve was loss of large nerve fibers andmore » perineural fibrosis without significant vascular injury. Similar histological changes in irradiated nerves were found in humans. To assess peripheral nerve injury to lower doses of intraoperative radiotherapy in this same large animal model, groups of four adult American Foxhounds received doses of 10, 15, or 20 Gy to the right lumbro-sacral plexus and sciatic nerve using 9 MeV electrons. The left lumbro-sacral plexus and sciatic nerve were excluded from the intraoperative field to allow each animal to serve as its own control. Following treatment, a complete neurological exam, electromyogram, and nerve conduction studies were performed monthly for 1 year. Monthly neurological exams were performed in years 2 and 3 whereas electromyogram and nerve conduction studies were performed every 3 months during this follow-up period. With follow-up of greater than or equal to 42 months, no dog receiving 10 or 15 Gy IORT shows any clinical or laboratory evidence of peripheral nerve injury. However, all four dogs receiving 20 Gy developed right hind limb paresis at 8, 9, 9, and 12 mos following intraoperative radiotherapy.« less
NASA Astrophysics Data System (ADS)
Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko
2017-02-01
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were ⩽3 mm and ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases. This work was partly presented at the 58th Annual meeting of American Association of Physicists in Medicine.
Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko
2017-02-21
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were ⩽3 mm and ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases.
Methods and computer readable medium for improved radiotherapy dosimetry planning
Wessol, Daniel E.; Frandsen, Michael W.; Wheeler, Floyd J.; Nigg, David W.
2005-11-15
Methods and computer readable media are disclosed for ultimately developing a dosimetry plan for a treatment volume irradiated during radiation therapy with a radiation source concentrated internally within a patient or incident from an external beam. The dosimetry plan is available in near "real-time" because of the novel geometric model construction of the treatment volume which in turn allows for rapid calculations to be performed for simulated movements of particles along particle tracks therethrough. The particles are exemplary representations of alpha, beta or gamma emissions emanating from an internal radiation source during various radiotherapies, such as brachytherapy or targeted radionuclide therapy, or they are exemplary representations of high-energy photons, electrons, protons or other ionizing particles incident on the treatment volume from an external source. In a preferred embodiment, a medical image of a treatment volume irradiated during radiotherapy having a plurality of pixels of information is obtained.
Momm, Felix; Jooss, David; Xander, Carola J; Adebahr, Sonja; Duncker-Rohr, Viola; Heinemann, Felix; Kirste, Simon; Messmer, Marc-Benjamin; Grosu, Anca-Ligia; Becker, Gerhild
2011-11-01
In the context of quality assurance, increasing demands are placed on the whole radiotherapy treatment process. The patients directly concerned generally do not realize most aspects of the quality assurance program (e.g., additional safety checks) during their daily therapy. It was the aim of this study to systematically ask patients about potential improvements during the course of radiotherapy treatment from their own perspective. In the defined time span (1 month), 624 radiotherapy patients (600 questionnaires were returned, 96.2%) were interviewed using a questionnaire newly developed to inquire about several aspects of their treatment. Furthermore, they were asked for their specific needs and suggestions for improvements that could be made during the course of radiotherapy treatment. Overall, the patients were satisfied with the course of their radiotherapy treatment and with patient care. As an example, about 90% agreed with the statement: "My first contact with the radiation oncology unit proceeded with kindness and competence so that I was given the impression that I will be well cared for in this clinic." Considering the organization of the course of radiotherapy, a large majority of patients attached great value to set appointments for the therapy fractions. A main point of criticism was waiting times or delays caused by servicing or machine failures. Small, low cost improvements as music in the therapy room were considered as important as expensive measures (e.g., daylight in the therapy room). The patients emphasized the importance of staff friendliness. The situation of radiotherapy patients was, in general, satisfactory. Future improvements can be mainly expected from smooth organisation of both planning and treatment which can be achieved by electronic scheduling systems. Many results of the survey could be easily implemented in daily practice. In matters of organization radiation oncology with its complex procedures can be used as a model for other clinical departments.
Efficacy and Interaction of Antioxidant Supplements as Adjuvant Therapy in Cancer Treatment
Yasueda, Asuka; Urushima, Hayato; Ito, Toshinori
2015-01-01
Oxidative stress is a key component in carcinogenesis. Although radiation produces reactive oxygen species, some anticancer agents such as alkylating agents, platinum and antitumor antibiotics exert cytotoxicity by generating free radicals. Nonenzymatic exogenous antioxidants such as vitamins, minerals, and polyphenols can quench ROS activity. However, whether antioxidants alter antitumor effects during radiotherapy and some types of chemotherapy remains unclear. In the present study, we reviewed antioxidants as an adjuvant therapy for cancer patients during chemotherapy or radiotherapy. Electronic literature searches were performed to select all randomized controlled clinical trials (RCTs) in which antioxidants were administered to cancer patients along with chemotherapy or radiotherapy. Articles or abstracts written in English were included. In total, 399 reports received primary screening. Duplicated articles and those meeting the exclusion criteria (not RCT, not human, and no oral administration) were excluded. Finally, 49 reports matching the inclusion criteria were included. It was difficult to determine whether antioxidants affect treatment outcomes or whether antioxidants ameliorate adverse effects induced by chemotherapy and radiotherapy. It is desirable to use an evidence-based method to select supplements best suited to cancer patients. Although there are many opinions about risks or benefits of antioxidant supplementation, we could mostly conclude that the harm caused by antioxidant supplementation remains unclear for patients during cancer therapy, except for smokers undergoing radiotherapy. PMID:26503419
Darvish, L; Ghorbani, M; Teshnizi, S Hosseini; Roozbeh, N; Seif, F; Bayatiani, M Reza; Knaup, C; Amraee, A
2018-05-14
Radiotherapy can often lead to thyroid dysfunction. Some studies demonstrated that treatment of breast cancer by RT can expose thyroid gland to high doses of radiation. The aim of this systematic review is to evaluate consideration of thyroid gland as an organ at risk. In this systematic review and meta-analysis to select initial studies, a comprehensive search by two independent reviewers was performed. Electronical databases following: Web of Science, Google Scholar, Scopus, PubMed, Elsevier, Embase, ProQuest and Persian databases such as Iranmedex, Magiran, and SID were searched. All searches were restricted to English language between 1985 and 2017. A random effect meta-analysis is applied to estimate pooled effect size across initial studies. Funnel plot with Egger's test is used to assess potential publication bias. Totally, five studies (478 samples) were included in meta-analysis. The meta-analyses of result showed that thyroid gland is affected by radiotherapy significantly and the TSH increased after radiotherapy (z = 2.68, P = 0.007). The pooled estimate of difference mean for TSH was 0.90 (95% CI 0.24, 1.55). In studies among patients with breast cancer RT, hypothyroidism was reported more than other thyroid disorders. There was not showed possibility publication bias among studies (P > 0.05). This study demonstrated that thyroid gland is affected by radiotherapy significantly and the TSH increased after radiotherapy. Protecting thyroid gland during radiation and follow-up of patients with breast cancer RT are suggested for the assessment of thyroid gland dysfunction.
A Radiobiological Analysis of Multicenter Data for Postoperative Keloid Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flickinger, John C., E-mail: flickingerjc@upmc.ed
2011-03-15
Purpose: To identify factors significantly affecting recurrence rates after postoperative external beam radiotherapy (XRT) of keloids, and to delineate any radiation dose response and effects of radiation dose per fraction. Methods and Materials: A comprehensive literature review was performed to compile a database of 2,515 resected keloids (36.9% earlobe). Postoperative XRT was 45- to 100-kV X-rays in 27.0% or 120- to 250-kV X-rays in 11.1%, Co-60 in 1.9%, Sr-90 in 4.7%, 1.5- to 9-MeV electrons in 26.5%, and no XRT in 28.8%. In the 1,791 irradiated patients, the median radiation parameters were as follows: total dose, 15 Gy (range, 6-30more » Gy); dose per fraction, 5.0 Gy (range, 2-15 Gy); fractions, 3 (range, 1-10); and time, 7 days (range, 0-33 days). Results: Multivariate stepwise logistic regression correlated decreased keloid recurrence with earlobe location (p = 1.98E-10; odds ratio, 0.34), biologically effective dose (p = 1.01E-27), and treatment with electron beam or Co-60 vs. other techniques (p = 0.0014; odds ratio, 0.72). Different radiobiological models calculated values of {alpha}/{beta} = 1.12 to 2.86 (mean, 2.08) and time (repopulation) correction factors for biologically effective dose from 0.98 to 2.13 Gy per day (mean, 1.34) starting 10 days after surgery. Different models (with {alpha}/{beta} = 2.08) predicted that doses needed for 90% and 95% control with 3 fractions of postoperative electron beam were 16.0 to 16.2 Gy and 18.3 to 19.2 Gy, respectively, in less than 10 days for earlobe keloids and 21.5 to 22.2 Gy and 23.4 to 24.8 Gy, respectively, in less than 10 days for other sites. Conclusions: Postoperative keloid radiotherapy requires moderately high doses and optimal technique to be effective. The relatively low {alpha}/{beta} ratio indicates that radiotherapy with a limited number of fractions and high doses per fraction is the best strategy.« less
Chetty, Indrin J; Curran, Bruce; Cygler, Joanna E; DeMarco, John J; Ezzell, Gary; Faddegon, Bruce A; Kawrakow, Iwan; Keall, Paul J; Liu, Helen; Ma, C M Charlie; Rogers, D W O; Seuntjens, Jan; Sheikh-Bagheri, Daryoush; Siebers, Jeffrey V
2007-12-01
The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its proven accuracy and the potential for improved dose distributions to influence treatment outcomes, the long calculation times previously associated with MC simulation rendered this method impractical for routine clinical treatment planning. However, the development of faster codes optimized for radiotherapy calculations and improvements in computer processor technology have substantially reduced calculation times to, in some instances, within minutes on a single processor. These advances have motivated several major treatment planning system vendors to embark upon the path of MC techniques. Several commercial vendors have already released or are currently in the process of releasing MC algorithms for photon and/or electron beam treatment planning. Consequently, the accessibility and use of MC treatment planning algorithms may well become widespread in the radiotherapy community. With MC simulation, dose is computed stochastically using first principles; this method is therefore quite different from conventional dose algorithms. Issues such as statistical uncertainties, the use of variance reduction techniques, the ability to account for geometric details in the accelerator treatment head simulation, and other features, are all unique components of a MC treatment planning algorithm. Successful implementation by the clinical physicist of such a system will require an understanding of the basic principles of MC techniques. The purpose of this report, while providing education and review on the use of MC simulation in radiotherapy planning, is to set out, for both users and developers, the salient issues associated with clinical implementation and experimental verification of MC dose algorithms. As the MC method is an emerging technology, this report is not meant to be prescriptive. Rather, it is intended as a preliminary report to review the tenets of the MC method and to provide the framework upon which to build a comprehensive program for commissioning and routine quality assurance of MC-based treatment planning systems.
National survey of perspectives of palliative radiation therapy: role, barriers, and needs.
McCloskey, Susan A; Tao, May Lin; Rose, Christopher M; Fink, Arlene; Amadeo, Alessandra M
2007-01-01
Despite growth of palliative care programs and evidence on the effectiveness of radiotherapy in palliating cancer symptoms, radiotherapy is probably underused in this setting. Radiation and medical oncologists and palliative medicine specialists were surveyed regarding the perceived role of palliative radiotherapy and barriers to its use. The survey was sent electronically to all physician members of the American Society for Therapeutic Radiology and Oncology (ASTRO) and the American Academy of Hospice and Palliative Medicine (AAHPM) and a random sample of American Society of Clinical Oncology (ASCO) members, with known e-mail addresses. Response rates were 27%, 14% and 26% for ASTRO, ASCO, and AAHPM respondents, respectively. Although most felt radiotherapy is an effective and important option for palliation of some common cancer symptoms, referrals for such therapy may be declining. Most agreed that radiation oncologists should be more involved in palliative care; however, multiple barriers were identified, such as poor reimbursement, emotional burden of care, insufficient training/knowledge, and the sense of unwillingness of others to share delivery of such services. Although multiple barriers limit optimal integration, most agree that there should be greater national and professional society efforts to promote the advancement of radiation oncology in the area of palliative care.
Richardson, Susan; Garcia-Ramirez, Jose; Lu, Wei; Myerson, Robert J; Parikh, Parag
2012-11-01
To present design aspects and acceptance tests performed for clinical implementation of electronic brachytherapy treatment of early stage rectal adenocarcinoma. A dosimetric comparison is made between the historically used Philips RT-50 unit and the newly developed Axxent(®) Model S700 electronic brachytherapy source manufactured by Xoft (iCad, Inc.). Two proctoscope cones were manufactured by ElectroSurgical Instruments (ESI). Two custom surface applicators were manufactured by Xoft and were designed to fit and interlock with the proctoscope cones from ESI. Dose rates, half value layers (HVL), and percentage depth dose (PDD) measurements were made with the Xoft system and compared to historical RT-50 data. A description of the patient treatment approach and exposure rates during the procedure is also provided. The electronic brachytherapy system has a lower surface dose rate than the RT-50. The dose rate to water on the surface from the Xoft system is approximately 2.1 Gy∕min while the RT-50 is 10-12 Gy∕min. However, treatment times with Xoft are still reasonable. The HVLs and PDDs between the two systems were comparable resulting in similar doses to the target and to regions beyond the target. The exposure rate levels around a patient treatment were acceptable. The standard uncertainty in the dose rate to water on the surface is approximately ±5.2%. The Philips RT-50 unit is an out-of-date radiotherapy machine that is no longer manufactured with limited replacement parts. The use of a custom-designed proctoscope and Xoft surface applicators allows delivery of a well-established treatment with the ease of a modern radiotherapy device. While the dose rate is lower with the use of Xoft, the treatment times are still reasonable. Additionally, personnel may stand farther away from the Xoft radiation source, thus potentially reducing radiation exposure to the operator and other personnel.
Intraoperative radiotherapy in combined treatment of sinonasal malignant tumors
NASA Astrophysics Data System (ADS)
Novikov, V. A.; Gribova, O. V.; Vasiljev, R. V.; Choynzonov, E. L.; Shtin, V. I.; Shiianova, A. A.; Surkova, P. V.; Starceva, Zh. A.; Shilova, O. G.
2017-09-01
Obvious advantage of IORT (intraoperative radiotherapy) is that the radiation source is delivered directly to the bed of the tumor during surgery, thus avoiding the negative impact on the skin, subcutaneous tissue and reducing the risk of fibrosis. Sinonasal tumors—a convenient object for intraoperative radiotherapy application (surface location, relatively small size tumors, good operational access). The surface location and comparatively small size of neoplasms, good operational access provide an efficient and accurate transfer of the electron beam to the postoperative cavity to increase the irradiation dose in the areas of the most probable recurrence, which makes the tumors of this localization a convenient object for the use of the intraoperative radiation therapy. The treatment was conducted using a mobile compact betatron (MIB-6E), 10-12 Gy single dose. IORT session extends surgery period by 30 min. There were no pathological clinical and laboratory reactions on IORT in the early postoperative period. Carrying out the procedure is possible in various standard operating rooms. It does not require special security measures for the patients and the staff. IORT with the help of electron beam allows avoiding post-radiation reactions and achieving a 5-year—disease-free survival of 66% of the patients. IORT session is possible through a minimal incision during organ preservation surgeries. Evident economic feasibility provides the prospects of applying IORT in the clinical practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kastrati, Labinot, E-mail: labinotkastrati82@gmail.com; Nafezi, Gazmend, E-mail: gazmend-nafezi@hotmail.com; Shehi, Gëzim, E-mail: gezimshehi@yahoo.com
2016-03-25
The Ionising irradiations used mostly in the treatment of tumoral diseases are: X, γ, β and e irradiations. The discussion will be about radiations, produced in accelerators, with photon energy 6 MV and 15 MV and electron energy from 5 MeV to 15 MeV. Due to the differences between γ and β radiations, their absorbtion in living tissues will be different. It is important to know, the absorption performance before and after the electronic equilibrium. For these purposes, we’ve use the function of dose gradient, for irradiations γ and β. It represents the velocity of dose change as a function of depthmore » in tissue. From skin to maximum dose value, the increase of G-function is more accentuated for γ-rays than for β-particles, while after that the G-function decreasing is less sharp for γ-rays, while for β-particles, it is almost promptly. This fact allow us to use in radiotherapy, not only γ-rays but β-particles, too. The lasts, represents, a much more efficient tool, especially in terms of radiation protection, of health adjacent tissues and organs. Finally, we’ll to discus, about the advantages in terms of radiation protection of both, γ-rays and β-particles used in radiotherapy.« less
Alves, G G; Kinoshita, A; Oliveira, H F de; Guimarães, F S; Amaral, L L; Baffa, O
2015-07-01
Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.
Yukihara, E G; Mardirossian, G; Mirzasadeghi, M; Guduru, S; Ahmad, S
2008-01-01
This article investigates the performance of Al2O3: C optically stimulated luminescence dosimeters (OSLDs) for application in radiotherapy. Central-axis depth dose curves and optically stimulated luminescence (OSL) responses were obtained in a water phantom for 6 and 18 MV photons, and for 6, 9, 12, 16, and 20 MeV electron beams from a Varian 21EX linear accelerator. Single OSL measurements could be repeated with a precision of 0.7% (one standard deviation) and the differences between absorbed doses measured with OSLDs and an ionization chamber were within +/- 1% for photon beams. Similar results were obtained for electron beams in the low-gradient region after correction for a 1.9% photon-to-electron bias. The distance-to-agreement values were of the order of 0.5-1.0 mm for electrons in high dose gradient regions. Additional investigations also demonstrated that the OSL response dependence on dose rate, field size, and irradiation temperature is less than 1% in the conditions of the present study. Regarding the beam energy/quality dependence, the relative response of the OSLD for 18 MV was (0.51 +/- 0.48)% of the response for the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam was in average 1.9% higher, but this result requires further confirmation. The relative response did not seem to vary with electron energy at dmax within the experimental uncertainties (0.5% in average) and, therefore, a fixed correction factor of 1.9% eliminated the energy dependence in our experimental conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yukihara, E. G.; Mardirossian, G.; Mirzasadeghi, M.
This article investigates the performance of Al{sub 2}O{sub 3}:C optically stimulated luminescence dosimeters (OSLDs) for application in radiotherapy. Central-axis depth dose curves and optically stimulated luminescence (OSL) responses were obtained in a water phantom for 6 and 18 MV photons, and for 6, 9, 12, 16, and 20 MeV electron beams from a Varian 21EX linear accelerator. Single OSL measurements could be repeated with a precision of 0.7% (one standard deviation) and the differences between absorbed doses measured with OSLDs and an ionization chamber were within {+-}1% for photon beams. Similar results were obtained for electron beams in the low-gradientmore » region after correction for a 1.9% photon-to-electron bias. The distance-to-agreement values were of the order of 0.5-1.0 mm for electrons in high dose gradient regions. Additional investigations also demonstrated that the OSL response dependence on dose rate, field size, and irradiation temperature is less than 1% in the conditions of the present study. Regarding the beam energy/quality dependence, the relative response of the OSLD for 18 MV was (0.51{+-}0.48)% of the response for the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam was in average 1.9% higher, but this result requires further confirmation. The relative response did not seem to vary with electron energy at d{sub max} within the experimental uncertainties (0.5% in average) and, therefore, a fixed correction factor of 1.9% eliminated the energy dependence in our experimental conditions.« less
Yohannes, Indra; Kolditz, Daniel; Langner, Oliver; Kalender, Willi A
2012-03-07
Tissue- and water-equivalent materials (TEMs) are widely used in quality assurance and calibration procedures, both in radiodiagnostics and radiotherapy. In radiotherapy, particularly, the TEMs are often used for computed tomography (CT) number calibration in treatment planning systems. However, currently available TEMs may not be very accurate in the determination of the calibration curves due to their limitation in mimicking radiation characteristics of the corresponding real tissues in both low- and high-energy ranges. Therefore, we are proposing a new formulation of TEMs using a stoichiometric analysis method to obtain TEMs for the calibration purposes. We combined the stoichiometric calibration and the basic data method to compose base materials to develop TEMs matching standard real tissues from ICRU Report 44 and 46. First, the CT numbers of six materials with known elemental compositions were measured to get constants for the stoichiometric calibration. The results of the stoichiometric calibration were used together with the basic data method to formulate new TEMs. These new TEMs were scanned to validate their CT numbers. The electron density and the stopping power calibration curves were also generated. The absolute differences of the measured CT numbers of the new TEMs were less than 4 HU for the soft tissues and less than 22 HU for the bone compared to the ICRU real tissues. Furthermore, the calculated relative electron density and electron and proton stopping powers of the new TEMs differed by less than 2% from the corresponding ICRU real tissues. The new TEMs which were formulated using the proposed technique increase the simplicity of the calibration process and preserve the accuracy of the stoichiometric calibration simultaneously.
Kilovoltage energy imaging with a radiotherapy linac with a continuously variable energy range.
Roberts, D A; Hansen, V N; Thompson, M G; Poludniowski, G; Niven, A; Seco, J; Evans, P M
2012-03-01
In this paper, the effect on image quality of significantly reducing the primary electron energy of a radiotherapy accelerator is investigated using a novel waveguide test piece. The waveguide contains a novel variable coupling device (rotovane), allowing for a wide continuously variable energy range of between 1.4 and 9 MeV suitable for both imaging and therapy. Imaging at linac accelerating potentials close to 1 MV was investigated experimentally and via Monte Carlo simulations. An imaging beam line was designed, and planar and cone beam computed tomography images were obtained to enable qualitative and quantitative comparisons with kilovoltage and megavoltage imaging systems. The imaging beam had an electron energy of 1.4 MeV, which was incident on a water cooled electron window consisting of stainless steel, a 5 mm carbon electron absorber and 2.5 mm aluminium filtration. Images were acquired with an amorphous silicon detector sensitive to diagnostic x-ray energies. The x-ray beam had an average energy of 220 keV and half value layer of 5.9 mm of copper. Cone beam CT images with the same contrast to noise ratio as a gantry mounted kilovoltage imaging system were obtained with doses as low as 2 cGy. This dose is equivalent to a single 6 MV portal image. While 12 times higher than a 100 kVp CBCT system (Elekta XVI), this dose is 140 times lower than a 6 MV cone beam imaging system and 6 times lower than previously published LowZ imaging beams operating at higher (4-5 MeV) energies. The novel coupling device provides for a wide range of electron energies that are suitable for kilovoltage quality imaging and therapy. The imaging system provides high contrast images from the therapy portal at low dose, approaching that of gantry mounted kilovoltage x-ray systems. Additionally, the system provides low dose imaging directly from the therapy portal, potentially allowing for target tracking during radiotherapy treatment. There is the scope with such a tuneable system for further energy reduction and subsequent improvement in image quality.
Characterisation and novel applications of glass beads as dosimeters in radiotherapy
NASA Astrophysics Data System (ADS)
Jafari, Shakardokht
The intent of external beam radiotherapy is to deliver as high a radiation dose as possible to tumour volume whilst minimizing the dose to surrounding normal tissues. Recent development of techniques such as intensity modulated radiation therapy (IMRT) and stereotactic ablative body radiotherapy (SABR) aim to extend this capability. The main feature of these techniques is to use beams which often contain small fields and very steep dose gradients. These present several dosimetric challenges including loss of charge particle equilibrium (CPE), partial occlusion of the direct-beam source and steep fall-off in dose in the penumbra. Dosimeters which are small in size relative to the radiation field dimensions are recommended for such conditions. The particular glass beads studied herein have several potentially favourable physical characteristics; they are small in size (1 to 3 mm diameter), chemically inert, inexpensive, readily available and reusable. The dosimetric characterisation of glass beads has been obtained by irradiating them in various radiotherapy beams of kilo-voltage and mega-voltage photons, megavoltage electrons, protons and carbon ions. They exhibit minimal fading compared with commercial LiF thermo-luminescent (TL) dosimeters, have high TL light transparency, high sensitivity and a large dynamic dose range that remains linear from 1 cGy to 100 Gy They have also been shown to be independent of dose rate and beam incidence angle, as well as having a low variation in response with energy over a range of megavoltage photon and electron beams. The latter characteristic is of importance, where spectral changes may occur as a function of field size and off axis location and for the use of dosimeters in postal audit situations where each institution may have slightly different quality index (QI) for their respective photon energies thus ensuring that the calibration is still valid. These properties suggest their practical use as TL dosimeters for radiotherapy dosimetry. Investigations have been performed to evaluate the feasibility of using glass beads in treatment plan verification, small field radiation dosimetry and postal dosimetry audit.
Mah, Li-Jeen; Orlowski, Christian; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C
2011-01-01
There is an intense interest in the development of radiopharmaceuticals for cancer therapy. In particular, radiopharmaceuticals which involve targeting radionuclides specifically to cancer cells with the use of monoclonal antibodies (radioimmunotherapy) or peptides (targeted radiotherapy) are being widely investigated. For example, the ultra-short range Auger electron-emitting isotopes, which are discussed in this review, are being considered in the context of DNAtargeted radiotherapy. The efficient quantitative evaluation of the levels of damage caused by such potential radiopharmaceuticals is required for assessment of therapeutic efficacy and determination of relevant doses for successful treatment. The DNA double-strand break surrogate marker, γH2AX, has emerged as a useful biomonitor of damage and thus effectiveness of treatment, offering a highly specific and sensitive means of assessment. This review will cover the potential applications of γH2AX in nuclear medicine, in particular radionuclide therapy.
Freitas Soares, Eveline; Zago Naves, Lucas; Bertolazzo Correr, Américo; Costa, Ana Rosa; Consani, Simonides; Soares, Carlos José; Garcia-Godoy, Franklin; Correr-Sobrinho, Lourenço
2016-12-01
To investigate the effect of radiotherapy, doxycycline and adhesive systems on the microtensile bond strength (μTBS) of the dentin-composite interface. 60 human third molars were sectioned to expose middle dentin surface and distributed according to: (1) adhesive system (Adper Scotchbond MP and Clearfil SE Bond) applied, (2) application or not of doxycycline, and (3) submission to 60 Gy total radiation (2 Gy daily doses, 5 days/week for 6 weeks) before restoration procedure (RtRes); after restoration procedure (ResRt) or not submitted to radiotherapy (Control group). Specimens were tested for μTBS and mode of failure were evaluated under optical microscopy. The bonding interface was evaluated with a scanning electron microscope (SEM). Data was submitted to three-way ANOVA and Tukey's test (α= 0.05). There was no significant difference between the μTBS (MPa) of Adper Scotchbond MP (25.5±11.1) and Clearfil SE (27.6±9.1). Control (30.5±10.9) and ResRt (29.2±10.4) presented μTBS significantly higher than RtRes (23.1±7.2). Doxycycline (21.7±7.6) significantly reduced μTBS compared to groups without doxycycline application (33.6±8.6). Dentin cohesive failure mode was predominant for RtRes and mixed failure mode for ResRt. Mixed and adhesive failures were frequently observed in control groups. SEM showed adhesive penetration in dentin tubules in all groups, regardless of the radiotherapy and the application of doxycycline. The radiotherapy before composite restoration procedure decreased the μTBS. No statistical difference was observed between the adhesive systems. The doxycycline reduced μTBS regardless of the other conditions. Composite restoration procedure should be done before radiotherapy, regardless of the adhesive system used.
Ten-year results of quality assurance in radiotherapy chart round.
Taghavi Bayat, Bardia; Gill, Suki; Siva, Shankar; Tai, Keen Hun; Joon, Michael Lim; Foroudi, Farshad
2013-04-23
The Royal Australian and New Zealand College of Radiologists (RANZCR) initiated a unique instrument to audit the quality of patient notes and radiotherapy prescriptions. We present our experience collected over ten years from the use of the RANZCR audit instrument. In this study, the results of data collected prospectively from January 1999 to June 2009 through the audit instrument were assessed. Radiotherapy chart rounds were held weekly in the uro-oncology tumour stream and real time feedback was provided. Electronic medical records were retrospectively assessed in September 2009 to see if any omissions were subsequently corrected. In total 2597 patients were audited. One hundred and thirty seven (5%) patients had one hundred and ninety nine omissions in documentation or radiotherapy prescription. In 79% of chart rounds no omissions were found at all, in 12% of chart rounds one omission was found and in 9% of chart rounds two or more omissions were found. Out of 199 omissions, 95% were of record keeping and 2% were omissions in the treatment prescription. Of omissions, 152 (76%) were unfiled investigation results of which 77 (51%) were subsequently corrected. Real-time audit with feedback is an effective tool in assessing the standards of radiotherapy documentation in our department, and also probably contributed to the high level of attentiveness. A large proportion of omissions were investigation results, which highlights the need for an improved system of retrieval of investigation results in the radiation oncology department.
Water versus DNA: New insights into proton track-structure modeling in radiobiology and radiotherapy
Champion, Christophe; Quinto, Michele A.; Monti, Juan M.; ...
2015-09-25
Water is a common surrogate of DNA for modelling the charged particle-induced ionizing processes in living tissue exposed to radiations. The present study aims at scrutinizing the validity of this approximation and then revealing new insights into proton-induced energy transfers by a comparative analysis between water and realistic biological medium. In this context, a self-consistent quantum mechanical modelling of the ionization and electron capture processes is reported within the continuum distorted wave-eikonal initial state framework for both isolated water molecules and DNA components impacted by proton beams. Their respective probability of occurrence-expressed in terms of total cross sections-as well asmore » their energetic signature (potential and kinetic) are assessed in order to clearly emphasize the differences existing between realistic building blocks of living matter and the controverted water-medium surrogate. Thus the consequences in radiobiology and radiotherapy will be discussed in particular in view of treatment planning refinement aiming at better radiotherapy strategies.« less
NASA Astrophysics Data System (ADS)
Jeon, Hosang; Nam, Jiho; Lee, Jayoung; Park, Dahl; Baek, Cheol-Ha; Kim, Wontaek; Ki, Yongkan; Kim, Dongwon
2015-06-01
Accurate dose delivery is crucial to the success of modern radiotherapy. To evaluate the dose actually delivered to patients, in-vivo dosimetry (IVD) is generally performed during radiotherapy to measure the entrance doses. In IVD, a build-up device should be placed on top of an in-vivo dosimeter to satisfy the electron equilibrium condition. However, a build-up device made of tissue-equivalent material or metal may perturb dose delivery to a patient, and requires an additional laborious and time-consuming process. We developed a novel IVD method using a look-up table of conversion ratios instead of a build-up device. We validated this method through a monte-carlo simulation and 31 clinical trials. The mean error of clinical IVD is 3.17% (standard deviation: 2.58%), which is comparable to that of conventional IVD methods. Moreover, the required time was greatly reduced so that the efficiency of IVD could be improved for both patients and therapists.
Champion, C; Quinto, M A; Monti, J M; Galassi, M E; Weck, P F; Fojón, O A; Hanssen, J; Rivarola, R D
2015-10-21
Water is a common surrogate of DNA for modelling the charged particle-induced ionizing processes in living tissue exposed to radiations. The present study aims at scrutinizing the validity of this approximation and then revealing new insights into proton-induced energy transfers by a comparative analysis between water and realistic biological medium. In this context, a self-consistent quantum mechanical modelling of the ionization and electron capture processes is reported within the continuum distorted wave-eikonal initial state framework for both isolated water molecules and DNA components impacted by proton beams. Their respective probability of occurrence-expressed in terms of total cross sections-as well as their energetic signature (potential and kinetic) are assessed in order to clearly emphasize the differences existing between realistic building blocks of living matter and the controverted water-medium surrogate. Consequences in radiobiology and radiotherapy will be discussed in particular in view of treatment planning refinement aiming at better radiotherapy strategies.
Zhang, Chen; Zhao, Kuaile; Bu, Wenbo; Ni, Dalong; Liu, Yanyan; Feng, Jingwei; Shi, Jianlin
2015-02-02
Strong oxygen dependence and limited penetration depth are the two major challenges facing the clinical application of photodynamic therapy (PDT). In contrast, ionizing radiation is too penetrative and often leads to inefficient radiotherapy (RT) in the clinic because of the lack of effective energy accumulation in the tumor region. Inspired by the complementary advantages of PDT and RT, we present herein the integration of a scintillator and a semiconductor as an ionizing-radiation-induced PDT agent, achieving synchronous radiotherapy and depth-insensitive PDT with diminished oxygen dependence. In the core-shell Ce(III)-doped LiYF4@SiO2@ZnO structure, the downconverted ultraviolet fluorescence from the Ce(III)-doped LiYF4 nanoscintillator under ionizing irradiation enables the generation of electron-hole (e(-)-h(+)) pairs in ZnO nanoparticles, giving rise to the formation of biotoxic hydroxyl radicals. This process is analogous to a type I PDT process for enhanced antitumor therapeutic efficacy. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Sempau, Josep; Wilderman, Scott J.; Bielajew, Alex F.
2000-08-01
A new Monte Carlo (MC) algorithm, the `dose planning method' (DPM), and its associated computer program for simulating the transport of electrons and photons in radiotherapy class problems employing primary electron beams, is presented. DPM is intended to be a high-accuracy MC alternative to the current generation of treatment planning codes which rely on analytical algorithms based on an approximate solution of the photon/electron Boltzmann transport equation. For primary electron beams, DPM is capable of computing 3D dose distributions (in 1 mm3 voxels) which agree to within 1% in dose maximum with widely used and exhaustively benchmarked general-purpose public-domain MC codes in only a fraction of the CPU time. A representative problem, the simulation of 1 million 10 MeV electrons impinging upon a water phantom of 1283 voxels of 1 mm on a side, can be performed by DPM in roughly 3 min on a modern desktop workstation. DPM achieves this performance by employing transport mechanics and electron multiple scattering distribution functions which have been derived to permit long transport steps (of the order of 5 mm) which can cross heterogeneity boundaries. The underlying algorithm is a `mixed' class simulation scheme, with differential cross sections for hard inelastic collisions and bremsstrahlung events described in an approximate manner to simplify their sampling. The continuous energy loss approximation is employed for energy losses below some predefined thresholds, and photon transport (including Compton, photoelectric absorption and pair production) is simulated in an analogue manner. The δ-scattering method (Woodcock tracking) is adopted to minimize the computational costs of transporting photons across voxels.
Characterization of the Exradin W1 scintillator for use in radiotherapy.
Carrasco, P; Jornet, N; Jordi, O; Lizondo, M; Latorre-Musoll, A; Eudaldo, T; Ruiz, A; Ribas, M
2015-01-01
To evaluate the main characteristics of the Exradin W1 scintillator as a dosimeter and to estimate measurement uncertainties when used in radiotherapy. We studied the calibration procedure, energy and modality dependence, short-term repeatability, dose-response linearity, angular dependence, temperature dependence, time to reach thermal equilibrium, dose-rate dependence, water-equivalent depth of the effective measurement point, and long-term stability. An uncertainty budget was derived for relative and absolute dose measurements in photon and electron beams. Exradin W1 showed a temperature dependence of -0.225% °C(-1). The loss of sensitivity with accumulated dose decreased with use. The sensitivity of Exradin W1 was energy independent for high-energy photon and electron beams. All remaining dependencies of Exradin W1 were around or below 0.5%, leading to an uncertainty budget of about 1%. When a dual channel electrometer with automatic trigger was not used, timing effects became significant, increasing uncertainties by one order of magnitude. The Exradin W1 response is energy independent for high energy x-rays and electron beams, and only one calibration coefficient is needed. A temperature correction factor should be applied to keep uncertainties around 2% for absolute dose measurements and around 1% for relative measurements in high-energy photon and electron beams. The Exradin W1 scintillator is an excellent alternative to detectors such as diodes for relative dose measurements.
Oshima, T; Aoyama, Y; Shimozato, T; Sawaki, M; Imai, T; Ito, Y; Obata, Y; Tabushi, K
2009-06-07
Intraoperative electron beam radiotherapy (IOERT) is a technique in which a single-fraction high dose is intraoperatively delivered to subclinical tumour cells using an electron beam after breast-conserving surgery. In IOERT, an attenuation plate consisting of a pair of metal disks is commonly used to protect the normal tissues posterior to the breast. However, the dose in front of the plate is affected by backscatter, resulting in an unpredictable delivered dose to the tumour cells. In this study, an experimental attenuation plate, termed a shielding plate, was designed using Monte Carlo simulation, which significantly diminished the electron beam without introducing any backscatter radiation. The plate's performance was verified by measurements. It was made of two layers, a first layer (source side) of polymethyl methacrylate (PMMA) and a second layer of copper, which was selected from among other metals (aluminium, copper and lead) after testing for shielding capability and the range and magnitude of backscatter. The optimal thicknesses of the PMMA (0.71 cm) and copper (0.3 cm) layers were determined by changing their thicknesses during simulations. On the basis of these results, a shielding plate was prototyped and depth doses with and without the plate were measured by radiophotoluminescence glass dosimeters using a conventional stationary linear accelerator and a mobile linear accelerator dedicated for IOERT. The trial shielding plate functioned as intended, indicating its applicability in clinical practice.
Proton therapy detector studies under the experience gained at the CATANA facility
NASA Astrophysics Data System (ADS)
Cuttone, G.; Cirrone, G. A. P.; Di Rosa, F.; Lojacono, P. A.; Lo Nigro, S.; Marino, C.; Mongelli, V.; Patti, I. V.; Pittera, S.; Raffaele, L.; Russo, G.; Sabini, M. G.; Salamone, V.; Valastro, L. M.
2007-10-01
Proton therapy represents the most promising radiotherapy technique for external tumor treatments. At Laboratori Nazionali del Sud of the Istituto Nazionale di Fisica Nucleare (INFN-LNS), Catania (I), a proton therapy facility is active since March 2002 and 140 patients, mainly affected by choroidal and iris melanoma, have been successfully treated. Proton beams are characterized by higher dose gradients and linear energy transfer with respect to the conventional photon and electron beams, commonly used in medical centers for radiotherapy.In this paper, we report the experience gained in the characterization of different dosimetric systems, studied and/or developed during the last ten years in our proton therapy facility.
MCNP simulation of a Theratron 780 radiotherapy unit.
Miró, R; Soler, J; Gallardo, S; Campayo, J M; Díez, S; Verdú, G
2005-01-01
A Theratron 780 (MDS Nordion) 60Co radiotherapy unit has been simulated with the Monte Carlo code MCNP. The unit has been realistically modelled: the cylindrical source capsule and its housing, the rectangular collimator system, both the primary and secondary jaws and the air gaps between the components. Different collimator openings, ranging from 5 x 5 cm2 to 20 x 20 cm2 (narrow and broad beams) at a source-surface distance equal to 80 cm have been used during the study. In the present work, we have calculated spectra as a function of field size. A study of the variation of the electron contamination of the 60Co beam has also been performed.
Radiotherapy Planning using MRI
Schmidt, Maria A; Payne, Geoffrey S
2016-01-01
The use of Magnetic Resonance Imaging (MRI) in Radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimised, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT. PMID:26509844
Richardson, Richard B; Harper, Mary-Ellen
2016-04-19
It has been more than 60 years since the discovery of the oxygen effect that empirically demonstrates the direct association between cell radiosensitivity and oxygen tension, important parameters in radiotherapy. Yet the mechanisms underlying this principal tenet of radiobiology are poorly understood. Better understanding of the oxygen effect may explain difficulty in eliminating hypoxic tumor cells, a major cause of regrowth after therapy. Our analysis utilizes the Howard-Flanders and Alper formula, which describes the relationship of radiosensitivity with oxygen tension. Here, we assign and qualitatively assess the relative contributions of two important mechanisms. The first mechanism involves the emission of reactive oxygen species from the mitochondrial electron transport chain, which increases with oxygen tension. The second mechanism is related to an energy and repair deficit, which increases with hypoxia. Following a radiation exposure, the uncoupling of the oxidative phosphorylation system (proton leak) in mitochondria lowers the emission of reactive oxygen species which has implications for fractionated radiotherapy, particularly of hypoxic tumors. Our analysis shows that, in oxygenated tumor and normal cells, mitochondria, rather than the nucleus, are the primary loci of radiotherapy effects, especially for low linear energy transfer radiation. Therefore, the oxygen effect can be explained by radiation-induced effects in mitochondria that generate reactive oxygen species, which in turn indirectly target nuclear DNA.
Automated detection of a prostate Ni-Ti stent in electronic portal images.
Carl, Jesper; Nielsen, Henning; Nielsen, Jane; Lund, Bente; Larsen, Erik Hoejkjaer
2006-12-01
Planning target volumes (PTV) in fractionated radiotherapy still have to be outlined with wide margins to the clinical target volume due to uncertainties arising from daily shift of the prostate position. A recently proposed new method of visualization of the prostate is based on insertion of a thermo-expandable Ni-Ti stent. The current study proposes a new detection algorithm for automated detection of the Ni-Ti stent in electronic portal images. The algorithm is based on the Ni-Ti stent having a cylindrical shape with a fixed diameter, which was used as the basis for an automated detection algorithm. The automated method uses enhancement of lines combined with a grayscale morphology operation that looks for enhanced pixels separated with a distance similar to the diameter of the stent. The images in this study are all from prostate cancer patients treated with radiotherapy in a previous study. Images of a stent inserted in a humanoid phantom demonstrated a localization accuracy of 0.4-0.7 mm which equals the pixel size in the image. The automated detection of the stent was compared to manual detection in 71 pairs of orthogonal images taken in nine patients. The algorithm was successful in 67 of 71 pairs of images. The method is fast, has a high success rate, good accuracy, and has a potential for unsupervised localization of the prostate before radiotherapy, which would enable automated repositioning before treatment and allow for the use of very tight PTV margins.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lemanski, Claire; Azria, David; Thezenas, Simon
2006-04-01
Purpose: The standard radiotherapy (RT) of breast cancer consists of 50 Gy external beam RT (EBRT) to the whole breast followed by an electron boost of 10-16 Gy to the tumor bed, but this has several cosmetic disadvantages. Intraoperative radiotherapy (IORT) could be an alternative to overcome these. Methods and Materials: We evaluated 50 women with early breast cancer operated on in a dedicated IORT facility. Median dose of 10 Gy was delivered using 9-MeV electron beams. All patients received postoperative EBRT (50 Gy in 2 Gy fractions). Late toxicity and cosmetic results were assessed independently by two physicians accordingmore » to the Common Terminology Criteria for Adverse Event v3.0 grading system and the European Organization for Research and Treatment of Cancer questionnaires. Results: After a median follow-up of 9.1 years (range, 5-15 years), two local recurrences were observed within the primary tumor bed. At the time of analysis, 45 patients are alive with (n = 1) or without disease. Among the 42 disease-free remaining patients, 6 experienced Grade 2 late subcutaneous fibrosis within the boost area. Overall, the scores indicated a very good quality of life and cosmesis was good to excellent in the evaluated patients. Conclusion: Our results confirm that IORT given as a boost after breast-conserving surgery is a reliable alternative to conventional postoperative fractionated boost radiation.« less
Khan, Muhammad; Lin, Jie; Liao, Guixiang; Li, Rong; Wang, Baiyao; Xie, Guozhu; Zheng, Jieling; Yuan, Yawei
2017-07-01
Whole brain radiotherapy has been a standard treatment of brain metastases. Stereotactic radiosurgery provides more focal and aggressive radiation and normal tissue sparing but worse local and distant control. This meta-analysis was performed to assess and compare the effectiveness of whole brain radiotherapy alone, stereotactic radiosurgery alone, and their combination in the treatment of brain metastases based on randomized controlled trial studies. Electronic databases (PubMed, MEDLINE, Embase, and Cochrane Library) were searched to identify randomized controlled trial studies that compared treatment outcome of whole brain radiotherapy and stereotactic radiosurgery. This meta-analysis was performed using the Review Manager (RevMan) software (version 5.2) that is provided by the Cochrane Collaboration. The data used were hazard ratios with 95% confidence intervals calculated for time-to-event data extracted from survival curves and local tumor control rate curves. Odds ratio with 95% confidence intervals were calculated for dichotomous data, while mean differences with 95% confidence intervals were calculated for continuous data. Fixed-effects or random-effects models were adopted according to heterogeneity. Five studies (n = 763) were included in this meta-analysis meeting the inclusion criteria. All the included studies were randomized controlled trials. The sample size ranged from 27 to 331. In total 202 (26%) patients with whole brain radiotherapy alone, 196 (26%) patients receiving stereotactic radiosurgery alone, and 365 (48%) patients were in whole brain radiotherapy plus stereotactic radiosurgery group. No significant survival benefit was observed for any treatment approach; hazard ratio was 1.19 (95% confidence interval: 0.96-1.43, p = 0.12) based on three randomized controlled trials for whole brain radiotherapy only compared to whole brain radiotherapy plus stereotactic radiosurgery and hazard ratio was 1.03 (95% confidence interval: 0.82-1.29, p = 0.81) for stereotactic radiosurgery only compared to combined approach. Local control was best achieved when whole brain radiotherapy was combined with stereotactic radiosurgery. Hazard ratio 2.05 (95% confidence interval: 1.36-3.09, p = 0.0006) and hazard ratio 1.84 (95% confidence interval: 1.26-2.70, p = 0.002) were obtained from comparing whole brain radiotherapy only and stereotactic radiosurgery only to whole brain radiotherapy + stereotactic radiosurgery, respectively. No difference in adverse events for treatment difference; odds ratio 1.16 (95% confidence interval: 0.77-1.76, p = 0.48) and odds ratio 0.92 (95% confidence interval: 0.59-1.42, p = 71) for whole brain radiotherapy + stereotactic radiosurgery versus whole brain radiotherapy only and whole brain radiotherapy + stereotactic radiosurgery versus stereotactic radiosurgery only, respectively. Adding stereotactic radiosurgery to whole brain radiotherapy provides better local control as compared to whole brain radiotherapy only and stereotactic radiosurgery only with no difference in radiation related toxicities.
Gill, S; Younie, S; Rolfo, A; Thomas, J; Siva, S; Fox, C; Kron, T; Phillips, D; Tai, K H; Foroudi, F
2012-10-01
To compare the treatment time and cost of prostate cancer fiducial marker image-guided radiotherapy (IGRT) using orthogonal kilovoltage imaging (KVI) and automated couch shifts and orthogonal electronic portal imaging (EPI) and manual couch shifts. IGRT treatment delivery times were recorded automatically on either unit. Costing was calculated from real costs derived from the implementation of a new radiotherapy centre. To derive cost per minute for EPI and KVI units the total annual setting up and running costs were divided by the total annual working time. The cost per IGRT fraction was calculated by multiplying the cost per minute by the duration of treatment. A sensitivity analysis was conducted to test the robustness of our analysis. Treatment times without couch shift were compared. Time data were analysed for 8648 fractions, 6057 from KVI treatment and 2591 from EPI treatment from a total of 294 patients. The median time for KVI treatment was 6.0 min (interquartile range 5.1-7.4 min) and for EPI treatment it was 10.0 min (interquartile range 8.3-11.8 min) (P value < 0.0001). The cost per fraction for KVI was A$258.79 and for EPI was A$345.50. The cost saving per fraction for KVI varied between A$66.09 and A$101.64 by sensitivity analysis. In patients where no couch shift was made, the median treatment delivery time for EPI was 8.8 min and for KVI was 5.1 min. Treatment time is less on KVI units compared with EPI units. This is probably due to automation of couch shift and faster evaluation of imaging on KVI units. Annual running costs greatly outweigh initial setting up costs and therefore the cost per fraction was less with KVI, despite higher initial costs. The selection of appropriate IGRT equipment can make IGRT practical within radiotherapy departments. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
An investigation on some of the tumor treatment cases using x-rays and electron beams
NASA Astrophysics Data System (ADS)
Ucar, Burcu; Yigitoglu, Ibrahim; Arslan Kabalay, Ipek; Altiparmak, Duygu; Kilicaslan, Sinem
2015-07-01
In this work, we discussed some of the applications which X-rays and electron beam used in radiotherapy for tumor treatments. This study has been performed at Radiation Oncology Department, Medicine Faculty in Gaziosmanpasa University by using the VARIAN CLINICA DHX linear accelerator which is operated in the range of 6 MeV - 15 MeV. Processes for the treatments that X-rays used for pancreas, bladder and prostate tumors and the processes that the electron beam used for some of the derm tumors are studied. Effects of X-rays and electron beams to treatments process are examined and the obtained results are presented comparatively.
Value of the use of a combination of photons and electrons in radiotherapy (in French)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gharbi, H.E.A.; Rietsch, J.
1973-01-01
The modification of the distribution of the dose delivered in an electron beam by its addition to a photon beam is studied for three cases: electron beams of 10 to 30 MeV, x-ray beams produced by the same accelerator with gamma beams from /sup 60/Co, and thicknesses of 10 to 20 cm. The results showed that the dose distributions obtained in the combination of the two beams varies according to the energy (particularly the electron energy) and according to the contribution of the different beams and the geometric comparison of the irradiated region. The graphs presented show the relative contributionmore » or each beam. (JSR)« less
Uses of megavoltage digital tomosynthesis in radiotherapy
NASA Astrophysics Data System (ADS)
Sarkar, Vikren
With the advent of intensity modulated radiotherapy, radiation treatment plans are becoming more conformal to the tumor with the decreasing margins. It is therefore of prime importance that the patient be positioned correctly prior to treatment. Therefore, image guided treatment is necessary for intensity modulated radiotherapy plans to be implemented successfully. Current advanced imaging devices require costly hardware and software upgrade, and radiation imaging solutions, such as cone beam computed tomography, may introduce extra radiation dose to the patient in order to acquire better quality images. Thus, there is a need to extend current existing imaging device ability and functions while reducing cost and radiation dose. Existing electronic portal imaging devices can be used to generate computed tomography-like tomograms through projection images acquired over a small angle using the technique of cone-beam digital tomosynthesis. Since it uses a fraction of the images required for computed tomography reconstruction, use of this technique correspondingly delivers only a fraction of the imaging dose to the patient. Furthermore, cone-beam digital tomosynthesis can be offered as a software-only solution as long as a portal imaging device is available. In this study, the feasibility of performing digital tomosynthesis using individually-acquired megavoltage images from a charge coupled device-based electronic portal imaging device was investigated. Three digital tomosynthesis reconstruction algorithms, the shift-and-add, filtered back-projection, and simultaneous algebraic reconstruction technique, were compared considering the final image quality and radiation dose during imaging. A software platform, DART, was created using a combination of the Matlab and C++ languages. The platform allows for the registration of a reference Cone Beam Digital Tomosynthesis (CBDT) image against a daily acquired set to determine how to shift the patient prior to treatment. Finally, the software was extended to investigate if the digital tomosynthesis dataset could be used in an adaptive radiotherapy regimen through the use of the Pinnacle treatment planning software to recalculate dose delivered. The feasibility study showed that the megavoltage CBDT visually agreed with corresponding megavoltage computed tomography images. The comparative study showed that the best compromise between imaging quality and imaging dose is obtained when 11 projection images, acquired over an imaging angle of 40°, are used with the filtered back-projection algorithm. DART was successfully used to register reference and daily image sets to within 1 mm in-plane and 2.5 mm out of plane. The DART platform was also effectively used to generate updated files that the Pinnacle treatment planning system used to calculate updated dose in a rigidly shifted patient. These doses were then used to calculate a cumulative dose distribution that could be used by a physician as reference to decide when the treatment plan should be updated. In conclusion, this study showed that a software solution is possible to extend existing electronic portal imaging devices to function as cone-beam digital tomosynthesis devices and achieve daily requirement for image guided intensity modulated radiotherapy treatments. The DART platform also has the potential to be used as a part of adaptive radiotherapy solution.
Hypothyroidism After Radiotherapy for Nasopharyngeal Cancer Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Y.-H.; Wang, H-M.; Taipei Chang Gung Head and Neck Oncology Group, Chang Gung Memorial Hospital, Taoyuan, Taiwan
Purpose: The aim of this study was to determine the long-term incidence and possible predictive factors for posttreatment hypothyroidism in nasopharyngeal carcinoma (NPC) patients after radiotherapy. Methods and Materials: Four hundred and eight sequential NPC patients who had received regular annual thyroid hormone surveys prospectively after radiotherapy were included in this study. Median patient age was 47.3 years, and 286 patients were male. Thyroid function was prospectively evaluated by measuring thyroid-stimulating hormone (TSH) and serum free thyroxine (FT4) levels. Low FT4 levels indicated clinical hypothyroidism in this study. Results: With a median follow-up of 4.3 years (range, 0.54-19.7 years), themore » incidence of low FT4 level was 5.3%, 9.0%, and 19.1% at 3, 5, and 10 years after radiotherapy, respectively. Hypothyroidism was more common with early T stage (p = 0.044), female sex (p = 0.037), and three-dimensional conformal therapy with the altered fractionation technique (p = 0.005) after univariate analysis. N stage, chemotherapy, reirradiation, and neck electron boost did not affect the incidence of hypothyroidism. Younger age and conformal therapy were significant factors that determined clinical hypothyroidism after multivariate analysis. Overall, patients presented with a low FT4 level about 1 year after presenting with an elevated TSH level. Conclusion: Among our study group of NPC patients, 19.1% experienced clinical hypothyroidism by 10 years after treatment. Younger age and conformal therapy increased the risk of hypothyroidism. We suggest routine evaluation of thyroid function in NPC patients after radiotherapy. The impact of pituitary injury should be also considered.« less
A new methodological approach for PET implementation in radiotherapy treatment planning.
Bellan, Elena; Ferretti, Alice; Capirci, Carlo; Grassetto, Gaia; Gava, Marcello; Chondrogiannis, Sotirios; Virdis, Graziella; Marzola, Maria Cristina; Massaro, Arianna; Rubello, Domenico; Nibale, Otello
2012-05-01
In this paper, a new methodological approach to using PET information in radiotherapy treatment planning has been discussed. Computed tomography (CT) represents the primary modality to plan personalized radiation treatment, because it provides the basic electron density map for correct dose calculation. If PET scanning is also performed it is typically coregistered with the CT study. This operation can be executed automatically by a hybrid PET/CT scanner or, if the PET and CT imaging sets have been acquired through different equipment, by a dedicated module of the radiotherapy treatment planning system. Both approaches have some disadvantages: in the first case, the bore of a PET/CT system generally used in clinical practice often does not allow the use of certain bulky devices for patient immobilization in radiotherapy, whereas in the second case the result could be affected by limitations in window/level visualization of two different image modalities, and the displayed PET volumes can appear not to be related to the actual uptake into the patient. To overcome these problems, at our centre a specific procedure has been studied and tested in 30 patients, allowing good results of precision in the target contouring to be obtained. The process consists of segmentation of the biological target volume by a dedicated PET/CT console and its export to a dedicated radiotherapy system, where an image registration between the CT images acquired by the PET/CT scanner and a large-bore CT is performed. The planning target volume is contoured only on the large-bore CT and is used for virtual simulation, to individuate permanent skin markers on the patient.
Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers
NASA Astrophysics Data System (ADS)
Restuccia, Nancy; Torrisi, Lorenzo
2018-01-01
The synthesis of Au and Ag nanoparticles (NP) though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM) measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials) and in vivo (in mice), were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.
Monte Carlo treatment planning for molecular targeted radiotherapy within the MINERVA system
NASA Astrophysics Data System (ADS)
Lehmann, Joerg; Hartmann Siantar, Christine; Wessol, Daniel E.; Wemple, Charles A.; Nigg, David; Cogliati, Josh; Daly, Tom; Descalle, Marie-Anne; Flickinger, Terry; Pletcher, David; DeNardo, Gerald
2005-03-01
The aim of this project is to extend accurate and patient-specific treatment planning to new treatment modalities, such as molecular targeted radiation therapy, incorporating previously crafted and proven Monte Carlo and deterministic computation methods. A flexible software environment is being created that allows planning radiation treatment for these new modalities and combining different forms of radiation treatment with consideration of biological effects. The system uses common input interfaces, medical image sets for definition of patient geometry and dose reporting protocols. Previously, the Idaho National Engineering and Environmental Laboratory (INEEL), Montana State University (MSU) and Lawrence Livermore National Laboratory (LLNL) had accrued experience in the development and application of Monte Carlo based, three-dimensional, computational dosimetry and treatment planning tools for radiotherapy in several specialized areas. In particular, INEEL and MSU have developed computational dosimetry systems for neutron radiotherapy and neutron capture therapy, while LLNL has developed the PEREGRINE computational system for external beam photon-electron therapy. Building on that experience, the INEEL and MSU are developing the MINERVA (modality inclusive environment for radiotherapeutic variable analysis) software system as a general framework for computational dosimetry and treatment planning for a variety of emerging forms of radiotherapy. In collaboration with this development, LLNL has extended its PEREGRINE code to accommodate internal sources for molecular targeted radiotherapy (MTR), and has interfaced it with the plugin architecture of MINERVA. Results from the extended PEREGRINE code have been compared to published data from other codes, and found to be in general agreement (EGS4—2%, MCNP—10%) (Descalle et al 2003 Cancer Biother. Radiopharm. 18 71-9). The code is currently being benchmarked against experimental data. The interpatient variability of the drug pharmacokinetics in MTR can only be properly accounted for by image-based, patient-specific treatment planning, as has been common in external beam radiation therapy for many years. MINERVA offers 3D Monte Carlo-based MTR treatment planning as its first integrated operational capability. The new MINERVA system will ultimately incorporate capabilities for a comprehensive list of radiation therapies. In progress are modules for external beam photon-electron therapy and boron neutron capture therapy (BNCT). Brachytherapy and proton therapy are planned. Through the open application programming interface (API), other groups can add their own modules and share them with the community.
Magnetic field effects on the energy deposition spectra of MV photon radiation.
Kirkby, C; Stanescu, T; Fallone, B G
2009-01-21
Several groups worldwide have proposed various concepts for improving megavoltage (MV) radiotherapy that involve irradiating patients in the presence of a magnetic field-either for image guidance in the case of hybrid radiotherapy-MRI machines or for purposes of introducing tighter control over dose distributions. The presence of a magnetic field alters the trajectory of charged particles between interactions with the medium and thus has the potential to alter energy deposition patterns within a sub-cellular target volume. In this work, we use the MC radiation transport code PENELOPE with appropriate algorithms invoked to incorporate magnetic field deflections to investigate electron energy fluence in the presence of a uniform magnetic field and the energy deposition spectra within a 10 microm water sphere as a function of magnetic field strength. The simulations suggest only very minor changes to the electron fluence even for extremely strong magnetic fields. Further, calculations of the dose-averaged lineal energy indicate that a magnetic field strength of at least 70 T is required before beam quality will change by more than 2%.
NASA Astrophysics Data System (ADS)
Perrot, Y.; Degoul, F.; Auzeloux, P.; Bonnet, M.; Cachin, F.; Chezal, J. M.; Donnarieix, D.; Labarre, P.; Moins, N.; Papon, J.; Rbah-Vidal, L.; Vidal, A.; Miot-Noirault, E.; Maigne, L.
2014-05-01
The GATE Monte Carlo simulation platform based on the Geant4 toolkit is under constant improvement for dosimetric calculations. In this study, we explore its use for the dosimetry of the preclinical targeted radiotherapy of melanoma using a new specific melanin-targeting radiotracer labeled with iodine 131. Calculated absorbed fractions and S values for spheres and murine models (digital and CT-scan-based mouse phantoms) are compared between GATE and EGSnrc Monte Carlo codes considering monoenergetic electrons and the detailed energy spectrum of iodine 131. The behavior of Geant4 standard and low energy models is also tested. Following the different authors’ guidelines concerning the parameterization of electron physics models, this study demonstrates an agreement of 1.2% and 1.5% with EGSnrc, respectively, for the calculation of S values for small spheres and mouse phantoms. S values calculated with GATE are then used to compute the dose distribution in organs of interest using the activity distribution in mouse phantoms. This study gives the dosimetric data required for the translation of the new treatment to the clinic.
Brown, Paul D; Kline, Robert W; Petersen, Ivy A; Haddock, Michael G
2004-01-01
The treatment of the inguinal lymph nodes with radiotherapy is strongly influenced by the body habitus of the patient. The effect of 7 radiotherapy techniques on femoral head doses was studied. Three female patients of differing body habitus (ectomorph, mesomorph, endomorph) were selected. Radiation fields included the pelvis and contiguous inguinal regions and were representative of fields used in the treatment of cancers of the lower pelvis. Seven treatment techniques were compared. In the ectomorph and mesomorph, normal tissue complication probability (NTCP) for the femoral heads was lowest with use of anteroposterior (AP) and modified posteroanterior (PA) field with inguinal electron field supplements (technique 1). In the endomorph, NTCP was lowest with use of AP and modified PA field without electron field supplements (technique 2) or a 4-field approach (technique 6). Technique 1 for ectomorphs and mesomorphs and techniques 2 and 6 for endomorphs were optimal techniques for providing relatively homogeneous dose distributions within the target area while minimizing the dose to the femoral heads.
Improving the therapeutic ratio of craniospinal irradiation in medulloblastoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maor, M.H.; Fields, R.S.; Hogstrom, K.R.
1985-04-01
Radiation therapy delivered to the entire cerebrospinal axis is indicated for a number of pediatric brain tumors, especially medulloblastoma. Improved radiotherapy techniques have changed the near fatal prognosis for children with medulloblastoma to a 50%, 5-year survival. Nevertheless, the treatment results in substantial acute toxicity, and many survivors have serious sequelae. Refinements in radiotherapy technique, however, can improve the therapeutic ratio of the treatment by lowering its side effects. In the last year children who required craniospinal irradiation at M.D. Anderson Hospital were treated with 6 MV photons to the brain and primary tumor and with 15-17 MeV electrons tomore » the spinal canal. The elective dose to the whole brain was 30 Gy in 17 fractions and 30 Gy in 20 fractions to the spine. The primary tumor received an additional 20-25 Gy. An electron-beam dose distribution was drawn on a computerized tomography (CT) reconstructed sagittal plane. The treatment was well tolerated in the first five patients. It is projected that the current technique will cause fewer late effects and improve the tolerance to chemotherapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reft, C; Lu, Z; Noonan, J
2015-06-15
Purpose: An innovative small high intensity electron beams with energies from 6 to 12 MeV is being developed at Argonne National Laboratory to deliver an absorbed dose via a catheter to small malignant and nonmalignant lesions. This study reports on the initial dosimetric characteristics of this electron beam. These include output calibration, percent depth dose, beam profiles and leakage through the catheter. Methods: To simulate the narrow electron beam, the Argonne Wakefield Accelerator is used to produce high energy electron beams. The electron beam from the accelerator is monitored by measuring the current through a transmission coil while the beammore » shape is observed with a fluorescent screen. The dosimetry properties of the electron beam transmitting through bone and tissue-like materials are measured with nanodot optically stimulated luminescent dosimeters and EDR radiographic film. The 6 MV photon beam from a Varian True beam linac is used to calibrate both the OSLDs and the film. Results: The beam characteristics of the 12 MeV beam were measured. The properties of the small diameter, 5 mm, beam differs from that of broad clinical electron beams from radiotherapy linacs. Due to the lack of scatter from the narrow beam, the maximum dose is at the surface and the depth of the 50% depth dose is 35 mm compared to 51 mm for a clinical 12 MeV. The widths of the 90% isodose measured at the surface and depths of 2, 6, 12, and 16 mm varied from 6.6 to 8.8 mm while the widths of the FWHM isodose varied from 7.8 to 25.5 mm. Conclusion: Initial beam measurements show favorable dosimetric properties for its use in treating either small surface or internal lesions, particularly to deliver radiation at the time of surgery to maximize the dose to the lesion and spare normal tissue.« less
A novel electron accelerator for MRI-Linac radiotherapy.
Whelan, Brendan; Gierman, Stephen; Holloway, Lois; Schmerge, John; Keall, Paul; Fahrig, Rebecca
2016-03-01
MRI guided radiotherapy is a rapidly growing field; however, current electron accelerators are not designed to operate in the magnetic fringe fields of MRI scanners. As such, current MRI-Linac systems require magnetic shielding, which can degrade MR image quality and limit system flexibility. The purpose of this work was to develop and test a novel medical electron accelerator concept which is inherently robust to operation within magnetic fields for in-line MRI-Linac systems. Computational simulations were utilized to model the accelerator, including the thermionic emission process, the electromagnetic fields within the accelerating structure, and resulting particle trajectories through these fields. The spatial and energy characteristics of the electron beam were quantified at the accelerator target and compared to published data for conventional accelerators. The model was then coupled to the fields from a simulated 1 T superconducting magnet and solved for cathode to isocenter distances between 1.0 and 2.4 m; the impact on the electron beam was quantified. For the zero field solution, the average current at the target was 146.3 mA, with a median energy of 5.8 MeV (interquartile spread of 0.1 MeV), and a spot size diameter of 1.5 mm full-width-tenth-maximum. Such an electron beam is suitable for therapy, comparing favorably to published data for conventional systems. The simulated accelerator showed increased robustness to operation in in-line magnetic fields, with a maximum current loss of 3% compared to 85% for a conventional system in the same magnetic fields. Computational simulations suggest that replacing conventional DC electron sources with a RF based source could be used to develop medical electron accelerators which are robust to operation in in-line magnetic fields. This would enable the development of MRI-Linac systems with no magnetic shielding around the Linac and reduce the requirements for optimization of magnetic fringe field, simplify design of the high-field magnet, and increase system flexibility.
A novel electron accelerator for MRI-Linac radiotherapy
Whelan, Brendan; Gierman, Stephen; Holloway, Lois; Schmerge, John; Keall, Paul; Fahrig, Rebecca
2016-01-01
Purpose: MRI guided radiotherapy is a rapidly growing field; however, current electron accelerators are not designed to operate in the magnetic fringe fields of MRI scanners. As such, current MRI-Linac systems require magnetic shielding, which can degrade MR image quality and limit system flexibility. The purpose of this work was to develop and test a novel medical electron accelerator concept which is inherently robust to operation within magnetic fields for in-line MRI-Linac systems. Methods: Computational simulations were utilized to model the accelerator, including the thermionic emission process, the electromagnetic fields within the accelerating structure, and resulting particle trajectories through these fields. The spatial and energy characteristics of the electron beam were quantified at the accelerator target and compared to published data for conventional accelerators. The model was then coupled to the fields from a simulated 1 T superconducting magnet and solved for cathode to isocenter distances between 1.0 and 2.4 m; the impact on the electron beam was quantified. Results: For the zero field solution, the average current at the target was 146.3 mA, with a median energy of 5.8 MeV (interquartile spread of 0.1 MeV), and a spot size diameter of 1.5 mm full-width-tenth-maximum. Such an electron beam is suitable for therapy, comparing favorably to published data for conventional systems. The simulated accelerator showed increased robustness to operation in in-line magnetic fields, with a maximum current loss of 3% compared to 85% for a conventional system in the same magnetic fields. Conclusions: Computational simulations suggest that replacing conventional DC electron sources with a RF based source could be used to develop medical electron accelerators which are robust to operation in in-line magnetic fields. This would enable the development of MRI-Linac systems with no magnetic shielding around the Linac and reduce the requirements for optimization of magnetic fringe field, simplify design of the high-field magnet, and increase system flexibility. PMID:26936713
Use of electronic portal imaging devices for electron treatment verification.
Kairn, T; Aland, T; Crowe, S B; Trapp, J V
2016-03-01
This study aims to help broaden the use of electronic portal imaging devices (EPIDs) for pre-treatment patient positioning verification, from photon-beam radiotherapy to photon- and electron-beam radiotherapy, by proposing and testing a method for acquiring clinically-useful EPID images of patient anatomy using electron beams, with a view to enabling and encouraging further research in this area. EPID images used in this study were acquired using all available beams from a linac configured to deliver electron beams with nominal energies of 6, 9, 12, 16 and 20 MeV, as well as photon beams with nominal energies of 6 and 10 MV. A widely-available heterogeneous, approximately-humanoid, thorax phantom was used, to provide an indication of the contrast and noise produced when imaging different types of tissue with comparatively realistic thicknesses. The acquired images were automatically calibrated, corrected for the effects of variations in the sensitivity of individual photodiodes, using a flood field image. For electron beam imaging, flood field EPID calibration images were acquired with and without the placement of blocks of water-equivalent plastic (with thicknesses approximately equal to the practical range of electrons in the plastic) placed upstream of the EPID, to filter out the primary electron beam, leaving only the bremsstrahlung photon signal. While the electron beam images acquired using a standard (unfiltered) flood field calibration were observed to be noisy and difficult to interpret, the electron beam images acquired using the filtered flood field calibration showed tissues and bony anatomy with levels of contrast and noise that were similar to the contrast and noise levels seen in the clinically acceptable photon beam EPID images. The best electron beam imaging results (highest contrast, signal-to-noise and contrast-to-noise ratios) were achieved when the images were acquired using the higher energy electron beams (16 and 20 MeV) when the EPID was calibrated using an intermediate (12 MeV) electron beam energy. These results demonstrate the feasibility of acquiring clinically-useful EPID images of patient anatomy using electron beams and suggest important avenues for future investigation, thus enabling and encouraging further research in this area. There is manifest potential for the EPID imaging method proposed in this work to lead to the clinical use of electron beam imaging for geometric verification of electron treatments in the future.
Kortylewicz, Zbigniew P.; Kimura, Yu; Inoue, Kotaro; Mack, Elizabeth; Baranowska-Kortylewicz, Janina
2012-01-01
Targeted molecular radiotherapy opens unprecedented opportunities to eradicate cancer cells with minimal irradiation of normal tissues. Described in this study are radioactive cycloSaligenyl monophosphates designed to deliver lethal doses of radiation to cancer cells. These compounds can be radiolabeled with SPECT- and PET-compatible radionuclides as well as radionuclides suitable for Auger electron therapies. This characteristic provides an avenue for the personalized and comprehensive treatment strategy that comprises diagnostic imaging to identify sites of disease, followed by the targeted molecular radiotherapy based on the imaging results. The developed radiosynthetic methods produce no-carrier-added products with high radiochemical yield and purity. The interaction of these compounds with their target, butyrylcholinesterase, depends on the stereochemistry around the P atom. IC50 values are in the nM range. In vitro studies indicate that radiation doses delivered to the cell nucleus are sufficient to kill cells of several difficult to treat malignancies including glioblastoma, and ovarian and colorectal cancers. PMID:22339166
A radiation-tolerant electronic readout system for portal imaging
NASA Astrophysics Data System (ADS)
Östling, J.; Brahme, A.; Danielsson, M.; Iacobaeus, C.; Peskov, V.
2004-06-01
A new electronic portal imaging device, EPID, is under development at the Karolinska Institutet and the Royal Institute of Technology. Due to considerable demands on radiation tolerance in the radiotherapy environment, a dedicated electronic readout system has been designed. The most interesting aspect of the readout system is that it allows to read out ˜1000 pixels in parallel, with all electronics placed outside the radiation beam—making the detector more radiation resistant. In this work we are presenting the function of a small prototype (6×100 pixels) of the electronic readout board that has been tested. Tests were made with continuous X-rays (10-60 keV) and with α particles. The results show that, without using an optimised gas mixture and with an early prototype only, the electronic readout system still works very well.
The appearance and effects of metallic implants in CT images.
Kairn, T; Crowe, S B; Fogg, P; Trapp, J V
2013-06-01
The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging artefacts that may occur within the implants themselves. This study examines CT images of a set of simple metallic objects, immersed in water, in order to evaluate reliability and variability of CT numbers (Hounsfield units, HUs) within medical implants. Model implants with a range of sizes (heights from 2.2 to 49.6 mm), electron densities (from 2.3 to 7.7 times the electron density of water) and effective atomic numbers (from 3.9 to 9.0 times the effective atomic number of water in a CT X-ray beam) were created by stacking metal coins from several currencies. These 'implants' were CT scanned within a large (31.0 cm across) and a small (12.8 cm across) water phantom. Resulting HU values are as much as 50 % lower than the result of extrapolating standard electron density calibration data (obtained for tissue and bone densities) up to the metal densities and there is a 6 % difference between the results obtained by scanning with 120 and 140 kVp tube potentials. Profiles through the implants show localised cupping artefacts, within the implants, as well as a gradual decline in HU outside the implants that can cause the implants' sizes to be over estimated by 1.3-9.0 mm. These effects are exacerbated when the implants are scanned in the small phantom or at the side of the large phantom, due to reduced pre-hardening of the X-ray beam in these configurations. These results demonstrate the necessity of over-riding the densities of metallic implants, as well as their artefacts in tissue, in order to obtain accurate radiotherapy dose calculations.
Raaijmakers, A J E; Raaymakers, B W; Lagendijk, J J W
2008-02-21
Several institutes are currently working on the development of a radiotherapy treatment system with online MR imaging (MRI) modality. The main difference between their designs is the magnetic field strength of the MRI system. While we have chosen a 1.5 Tesla (T) magnetic field strength, the Cross Cancer Institute in Edmonton will be using a 0.2 T MRI scanner and the company Viewray aims to use 0.3 T. The magnetic field strength will affect the severity of magnetic field dose effects, such as the electron return effect (ERE): considerable dose increase at tissue air boundaries due to returning electrons. This paper has investigated how the ERE dose increase depends on the magnetic field strength. Therefore, four situations where the ERE occurs have been simulated: ERE at the distal side of the beam, the lateral ERE, ERE in cylindrical air cavities and ERE in the lungs. The magnetic field comparison values were 0.2, 0.75, 1.5 and 3 T. Results show that, in general, magnetic field dose effects are reduced at lower magnetic field strengths. At the distal side, the ERE dose increase is largest for B = 0.75 T and depends on the irradiation field size for B = 0.2 T. The lateral ERE is strongest for B = 3 T but shows no effect for B = 0.2 T. Around cylindrical air cavities, dose inhomogeneities disappear if the radius of the cavity becomes small relative to the in-air radius of the secondary electron trajectories. At larger cavities (r > 1 cm), dose inhomogeneities exist for all magnetic field strengths. In water-lung-water phantoms, the ERE dose increase takes place at the water-lung transition and the dose decreases at the lung-water transition, but these effects are minimal for B = 0.2 T. These results will contribute to evaluating the trade-off between magnetic field dose effects and image quality of MR-guided radiotherapy systems.
van den Blink, Qurrat U; Garcez, Kate; Henson, Caroline C; Davidson, Susan E; Higham, Claire E
2018-04-23
Pelvic radiotherapy is a treatment delivered to an estimated 150,000 to 300,000 people annually across high-income countries. Fractures due to normal stresses on weakened bone due to radiotherapy are termed insufficiency fractures. Pelvic radiotherapy-related interruption of the blood supply to the hip is termed avascular necrosis and is another recognised complication. The reported incidences of insufficiency fractures are 2.7% to 89% and risk of developing avascular necrosis is 0.5%. These complications lead to significant morbidity in terms of pain, immobility and consequently risk of infections, pressure sores and mortality. To assess the effects of pharmacological interventions for preventing insufficiency fractures and avascular necrosis in adults over 18 years of age undergoing pelvic radiotherapy. We performed electronic literature searches in the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase and DARE to 19 April 2017. We also searched trial registries. Further relevant studies were identified through handsearching of citation lists of included studies. Randomised controlled trials (RCTs) or non RCTs with concurrent comparison groups including quasi-RCTs, cluster RCTs, prospective cohort studies and case series of 30 or more participants were screened. We included studies assessing the effect of pharmacological interventions in adults over 18 years of age undergoing radical pelvic radiotherapy as part of anticancer treatment for a primary pelvic malignancy. We excluded studies involving radiotherapy for bone metastases. We assessed use of pharmacological interventions at any stage before or during pelvic radiotherapy. Interventions included calcium or vitamin D (or both) supplementation, bisphosphonates, selective oestrogen receptor modulators, hormone replacement therapy (oestrogen or testosterone), denosumab and calcitonin. Two review authors independently assessed trial quality and extracted data. We contacted study authors to obtain missing data. Data were to be pooled using the random-effects model if study comparisons were similar, otherwise results were to be reported narratively. We included two RCTs (1167 participants). The first RCT compared zoledronic acid with placebo in 96 men undergoing pelvic radiotherapy for non-metastatic prostate cancer.The second RCT had four treatment arms, two of which evaluated zoledronic acid plus adjuvant androgen suppression compared with androgen suppression only in 1071 men undergoing pelvic radiotherapy for non-metastatic prostate cancer.Both studies were at a moderate to high risk of bias and all evidence was judged to be of very low certainty.The studies provided no evidence on the primary outcomes of the review and provided limited data in relation to secondary outcomes, such that meta-analyses were not possible. Both studies focused on interventions to improve bone health in relation to androgen deprivation rather than radiation-related insufficiency fractures and avascular necrosis. Few fractures were described in each study and those described were not specific to insufficiency fractures secondary to radiotherapy. Both studies reported that zoledronic acid in addition to androgen deprivation and pelvic radiotherapy led to improvements in BMD; however, the changes in BMD were measured and reported differently. There was no available evidence regarding adverse effects. The evidence relating to interventions to prevent insufficiency fractures and avascular necrosis associated with pelvic radiotherapy in adults is of very low certainty. This review highlights the need for prospective clinical trials using interventions prior to and during radiotherapy to prevent radiation-related bone morbidity, insufficiency fractures and avascular necrosis. Future trials could involve prospective assessment of bone health including BMD and bone turnover markers prior to pelvic radiotherapy. The interventions for investigation could begin as radiotherapy commences and remain ongoing for 12 to 24 months. Bone turnover markers and BMD could be used as surrogate markers for bone health in addition to radiographic imaging to report on presence of insufficiency fractures and development of avascular necrosis. Clinical assessments and patient reported outcomes would help to identify any associated adverse effects of treatment and quality of life outcomes.
NASA Astrophysics Data System (ADS)
Kumar, Gokula; Norhafizah, I.; Shazril, I.; Nursyatina, AR; Aziz, MZ Abdul; Zin, Hafiz M.; Zakir, MK; Norjayadi; Norliza, AS; Ismail, A.; Khairun, N.
2017-05-01
This case report describes a complex radical 3D-Conformal Radiotherapy treatment planning, dosimetric issues and outcome of definitive treatment of un-resectable carcinoma of the vulvar in a 42-year old lady. The patient presented with large fungating mass of the vulva which was biopsy confirmed as Keratinizing Squamous Cell Carcinoma. Further staging investigation revealed locally advanced disease (T4), with bilateral inguinal lymph nodes involvement. There is no systemic metastasis or intra-pelvic nodes. The patient was seen by Gynae-Oncology team and the disease was deemed un-resectable without significant morbidity. She was treated to a total dose of 64.8Gy in 36 fractions over 7 weeks with concurrent weekly Cisplatinum in 2 phases. 3D-Conformal radiotherapy technique using the modified segmental boost technique (MSBT, large PA and small AP photon fields with inguinal electron matching) was used. TLD chips were used for in-vivo dose verification in phase 1 and 2 of the treatment. At completion of planned radiotherapy, patient had a complete clinical response, grade 2-3 skin toxicity, grade 2 rectal toxicity, and grade 2 dysuria Vulval Squamous Cell Carcinomas are very radiosensitive tumours and the skills of the treating Radiation Oncologist, Dosimetrists, Physicist, Radiation Therapist and also nurses is of foremost importance is ensuring good clinical outcomes.
NASA Astrophysics Data System (ADS)
Lee, Choonik; Jung, Jae Won; Pelletier, Christopher; Pyakuryal, Anil; Lamart, Stephanie; Kim, Jong Oh; Lee, Choonsik
2015-03-01
Organ dose estimation for retrospective epidemiological studies of late effects in radiotherapy patients involves two challenges: radiological images to represent patient anatomy are not usually available for patient cohorts who were treated years ago, and efficient dose reconstruction methods for large-scale patient cohorts are not well established. In the current study, we developed methods to reconstruct organ doses for radiotherapy patients by using a series of computational human phantoms coupled with a commercial treatment planning system (TPS) and a radiotherapy-dedicated Monte Carlo transport code, and performed illustrative dose calculations. First, we developed methods to convert the anatomy and organ contours of the pediatric and adult hybrid computational phantom series to Digital Imaging and Communications in Medicine (DICOM)-image and DICOM-structure files, respectively. The resulting DICOM files were imported to a commercial TPS for simulating radiotherapy and dose calculation for in-field organs. The conversion process was validated by comparing electron densities relative to water and organ volumes between the hybrid phantoms and the DICOM files imported in TPS, which showed agreements within 0.1 and 2%, respectively. Second, we developed a procedure to transfer DICOM-RT files generated from the TPS directly to a Monte Carlo transport code, x-ray Voxel Monte Carlo (XVMC) for more accurate dose calculations. Third, to illustrate the performance of the established methods, we simulated a whole brain treatment for the 10 year-old male phantom and a prostate treatment for the adult male phantom. Radiation doses to selected organs were calculated using the TPS and XVMC, and compared to each other. Organ average doses from the two methods matched within 7%, whereas maximum and minimum point doses differed up to 45%. The dosimetry methods and procedures established in this study will be useful for the reconstruction of organ dose to support retrospective epidemiological studies of late effects in radiotherapy patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brualla, Lorenzo, E-mail: lorenzo.brualla@uni-due.de; Zaragoza, Francisco J.; Sempau, Josep
Purpose: External beam radiotherapy is the only conservative curative approach for Stage I non-Hodgkin lymphomas of the conjunctiva. The target volume is geometrically complex because it includes the eyeball and lid conjunctiva. Furthermore, the target volume is adjacent to radiosensitive structures, including the lens, lacrimal glands, cornea, retina, and papilla. The radiotherapy planning and optimization requires accurate calculation of the dose in these anatomical structures that are much smaller than the structures traditionally considered in radiotherapy. Neither conventional treatment planning systems nor dosimetric measurements can reliably determine the dose distribution in these small irradiated volumes. Methods and Materials: The Montemore » Carlo simulations of a Varian Clinac 2100 C/D and human eye were performed using the PENELOPE and PENEASYLINAC codes. Dose distributions and dose volume histograms were calculated for the bulbar conjunctiva, cornea, lens, retina, papilla, lacrimal gland, and anterior and posterior hemispheres. Results: The simulated results allow choosing the most adequate treatment setup configuration, which is an electron beam energy of 6 MeV with additional bolus and collimation by a cerrobend block with a central cylindrical hole of 3.0 cm diameter and central cylindrical rod of 1.0 cm diameter. Conclusions: Monte Carlo simulation is a useful method to calculate the minute dose distribution in ocular tissue and to optimize the electron irradiation technique in highly critical structures. Using a voxelized eye phantom based on patient computed tomography images, the dose distribution can be estimated with a standard statistical uncertainty of less than 2.4% in 3 min using a computing cluster with 30 cores, which makes this planning technique clinically relevant.« less
Present and Future of Hadrontherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amaldi, Ugo; Department of Physics, University of Milano-Bicocca, Milan; Braccini, Saverio
2006-04-07
In the developed countries every 10 million inhabitants about 20'000 oncological patients are irradiated every year with high-energy photons (called X-rays by radiotherapists) produced by electron linacs. This is the so called 'conventional' radiotherapy. Hadrontherapy is a novel technique of radiotherapy which instead of X-rays employs beams of charged hadrons, protons and carbon ions in particular. Due to their physical and radiobiological properties, they allow to obtain a more conformal treatment than X-rays, sparing better the surrounding healthy tissues with a subsequent larger control rate. By now about 40,000 patients have been treated worldwide with protons and 15 hospital basedmore » centres are either running or under construction. Carbon ion beams deliver the dose as precisely as protons and are characterized by a larger biological effectiveness than X-rays and protons. They are therefore particularly suited to treat radio resistant tumours, as proven by the clinical studies performed on about 2300 patients in HIMAC (Chiba, Japan) and on about 250 patients at GSI (Darmstadt, Germany). A second Japanese hospital based centre is now running in Hyogo and two are under construction in Europe, in Heidelberg (Germany) and Pave (Italy). A large diffusion of hadrontherapy is foreseen in the near future but a much larger diffusion, possibly comparable with the one of electron linacs in conventional radiotherapy, will be achieved only if much compact and cheap accelerators and dose delivery systems will be conceived and constructed. In this framework, the acceleration of protons based on laser plasma techniques represents a very interesting and challenging possibility.« less
Oertel, Susanne; Niethammer, Andreas G; Krempien, Robert; Roeder, Falk; Eble, Michael J; Baer, Claudia; Huber, Peter E; Kulozik, Andreas; Waag, Karl-Ludwig; Treiber, Martina; Debus, Juergen
2006-01-01
Intraoperative electron-beam radiotherapy (IOERT) has been applied for local dose escalation in over 1,400 patients in Heidelberg since 1991. Among these were 30 children, in 18 of whom IOERT was employed in radiation treatment with external-beam radiotherapy (EBRT) on account of incomplete resection. We address the question whether IOERT is able to compensate for microscopic or macroscopic tumor residue if employed in the overall radiation regimen. The data of the aforementioned 18 children were analyzed with regard to local recurrence, overall survival, and complication rates. All children suffered from either sarcomas or neuroblastomas. In all children, IOERT was employed for local dose escalation after or before EBRT. After a median follow-up of 60.5 months, 15 of the treated children are alive. One local failure has been observed. Six children show clinically significant late morbidity, including the loss of a treated limb (Radiation Therapy Oncology Group Grade 4 [RTOG 4]), a severe nerve lesion (RTOG 3), an orthopedic complication (RTOG 2), a ureteral stenosis (not clinically significant), and a kidney hypotrophy (not clinically significant). In 1 child a fracture due to radionecrosis (RTOG 4) was diagnosed; however, in the follow-up, local tumor relapse was diagnosed as another possible reason for the fracture. Regarding the low incidence of local failure, IOERT seems to be able to compensate incomplete tumor resection in childhood sarcoma and neuroblastoma patients. The incidence of late morbidity is low enough to justify the employment of IOERT as part of the radiation treatment regimen for pediatric patients.
NASA Astrophysics Data System (ADS)
Marrale, Maurizio; Longo, Anna; Russo, Giorgio; Casarino, Carlo; Candiano, Giuliana; Gallo, Salvatore; Carlino, Antonio; Brai, Maria
2015-09-01
In this work a comparison between the response of alanine and Markus ionization chamber was carried out for measurements of the output factors (OF) of electron beams produced by a linear accelerator used for Intra-Operative Radiation Therapy (IORT). Output factors (OF) for conventional high-energy electron beams are normally measured using ionization chamber according to international dosimetry protocols. However, the electron beams used in IORT have characteristics of dose per pulse, energy spectrum and angular distribution quite different from beams usually used in external radiotherapy, so the direct application of international dosimetry protocols may introduce additional uncertainties in dosimetric determinations. The high dose per pulse could lead to an inaccuracy in dose measurements with ionization chamber, due to overestimation of ks recombination factor. Furthermore, the electron fields obtained with IORT-dedicated applicators have a wider energy spectrum and a wider angular distribution than the conventional fields, due to the presence of electrons scattered by the applicator's wall. For this reason, a dosimetry system should be characterized by a minimum dependence from the beam energy and from angle of incidence of electrons. This become particularly critical for small and bevelled applicators. All of these reasons lead to investigate the use of detectors different from the ionization chamber for measuring the OFs. Furthermore, the complete characterization of the radiation field could be accomplished also by the use of Monte Carlo simulations which allows to obtain detailed information on dose distributions. In this work we compare the output factors obtained by means of alanine dosimeters and Markus ionization chamber. The comparison is completed by the Monte Carlo calculations of OFs determined through the use of the Geant4 application "iort _ therapy" . The results are characterized by a good agreement of response of alanine pellets and Markus ionization chamber and Monte Carlo results (within about 3%) for both flat and bevelled applicators.
NASA Astrophysics Data System (ADS)
Smith, Clare L.; Ankers, Elizabeth; Best, Stephen P.; Gagliardi, Frank; Katahira, Kai; Tsunei, Yseu; Tominaga, Takahiro; Geso, Moshi
2017-12-01
The suitability of IRGANOX®1076 in paraffin wax as a near-tissue equivalent radiation dosimeter was investigated for various radiotherapy beam types; kV and MV X-rays, electrons and protons over clinically-relevant doses (2 -20 Gy). The radical formed upon exposure to ionising radiations was measured by Electron Paramagnetic Resonance (EPR) spectroscopy, and the single peak signal obtained for solid solutions of IRGANOX®1076 in wax is attributed to the phenoxyl radical obtained by net loss of H•. Irradiation of solid IRGANOX®1076 gives a doublet consistent with the formation of the phenol cation radical, obtained by electron loss. Solid solutions of IRGANOX®1076 in paraffin wax give a linear dose response for all types of radiations examined, which was energy independent for MV, electron and proton beams, and energy-dependent for kV X-ray irradiation. Reliable dose measurements were obtained with exposures as low as 2 Gy, and comparisons with alanine wax-pellets containing the same amount of dosimeter material (w/w) gave similar responses for all beam types investigated. Post-irradiation measurements (up to 77 days for proton irradiation for samples stored in the dark and at room temperature) indicate good signal stability with minimal signal fading (between 1.6 to 3.8%). Relative to alanine dosimeters, solid solutions of IRGANOX®1076 in wax give EPR signals with better sensitivity at low dose and do not significantly change with the orientation of the sample. Solid solutions of IRGANOX®1076 are ideal for applications in radiotherapy dosimetry for X-rays and charged particles, as IRGANOX®1076 is relatively cheap, can easily and reproducibly prepared in wax and be moulded to different shapes.
Dosimetry of Al2O3 optically stimulated luminescent dosimeter at high energy photons and electrons
NASA Astrophysics Data System (ADS)
Yusof, M. F. Mohd; Joohari, N. A.; Abdullah, R.; Shukor, N. S. Abd; Kadir, A. B. Abd; Isa, N. Mohd
2018-01-01
The linearity of Al2O3 OSL dosimeters (OSLD) were evaluated for dosimetry works in clinical photons and electrons. The measurements were made at a reference depth of Zref according to IAEA TRS 398:2000 codes of practice at 6 and 10 MV photons and 6 and 9 MeV electrons. The measured dose was compared to the thermoluminescence dosimeters (TLD) and ionization chamber commonly used for dosimetry works for higher energy photons and electrons. The results showed that the measured dose in OSL dosimeters were in good agreement with the reported by the ionization chamber in both high energy photons and electrons. A reproducibility test also reported excellent consistency of readings with the OSL at similar energy levels. The overall results confirmed the suitability of OSL dosimeters for dosimetry works involving high energy photons and electrons in radiotherapy.
Zecchin, Massimo; Severgnini, Mara; Fiorentino, Alba; Malavasi, Vincenzo Livio; Menegotti, Loris; Alongi, Filippo; Catanzariti, Domenico; Jereczek-Fossa, Barbara Alicja; Stasi, Michele; Russi, Elvio; Boriani, Giuseppe
2018-03-15
The management of patients with a cardiac implanted electronic device (CIED) receiving radiotherapy (RT) is challenging and requires a structured multidisciplinary approach. A consensus document is presented as a result of a multidisciplinary working group involving cardiac electrophysiologists, radiation oncologists and physicists in order to stratify the risk of patients with CIED requiring RT and approaching RT sessions appropriately. When high radiation doses and beam energy higher than 6MV are used, CIED malfunctions can occur during treatment. In our document, we reviewed the different types of RT and CIED behavior in the presence of ionizing radiations and electromagnetic interferences, from the cardiologist's, radiation oncologist's and medical physicist's point of view. We also reviewed in vitro and in vivo literature data and other national published guidelines on this issue so far. On the basis of literature data and consensus of experts, a detailed approach based on risk stratification and appropriate management of RT patients with CIEDs is suggested, with important implications for clinical practice. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Sabater, S; Montero, A; López Fernández, T; González Ferrer, J J; Arenas, M
2018-05-23
There is an increasing number of patients with cardiac implantable electronic devices (CIED), either pacemakers or defibrillators, who are receiving a course of radiotherapy. Several guidelines have been published by national societies, but no Spanish national guidelines for management of these patients have been published. More importantly, national clinical practice regarding these patients is not standardised. Members of the Spanish Breast Cancer Radiation Oncology Group (GEORM in Spanish) were surveyed through an online questionnaire on behalf of the Spanish radiation oncology departments. Only 39.3% of the Spanish radiation oncology departments have policies aimed at CIED carrier patients. Regardless of that, 96.4% of those who responded to the survey refer these patients to their Cardiology department before the start of the course of radiotherapy, and 17.8% of respondents said to manipulate the CIED without any cardiology department direction. A wide range of responses was obtained related to concepts such as "distance from the irradiation field to the CIED" or "safe accumulated doses". Our results demonstrate the need for national guidelines for CIED patients and the need to promote educational activities addressed to standardise clinical management of these patients in the radiation oncology departments.
ORANGE: a Monte Carlo dose engine for radiotherapy.
van der Zee, W; Hogenbirk, A; van der Marck, S C
2005-02-21
This study presents data for the verification of ORANGE, a fast MCNP-based dose engine for radiotherapy treatment planning. In order to verify the new algorithm, it has been benchmarked against DOSXYZ and against measurements. For the benchmarking, first calculations have been done using the ICCR-XIII benchmark. Next, calculations have been done with DOSXYZ and ORANGE in five different phantoms (one homogeneous, two with bone equivalent inserts and two with lung equivalent inserts). The calculations have been done with two mono-energetic photon beams (2 MeV and 6 MeV) and two mono-energetic electron beams (10 MeV and 20 MeV). Comparison of the calculated data (from DOSXYZ and ORANGE) against measurements was possible for a realistic 10 MV photon beam and a realistic 15 MeV electron beam in a homogeneous phantom only. For the comparison of the calculated dose distributions and dose distributions against measurements, the concept of the confidence limit (CL) has been used. This concept reduces the difference between two data sets to a single number, which gives the deviation for 90% of the dose distributions. Using this concept, it was found that ORANGE was always within the statistical bandwidth with DOSXYZ and the measurements. The ICCR-XIII benchmark showed that ORANGE is seven times faster than DOSXYZ, a result comparable with other accelerated Monte Carlo dose systems when no variance reduction is used. As shown for XVMC, using variance reduction techniques has the potential for further acceleration. Using modern computer hardware, this brings the total calculation time for a dose distribution with 1.5% (statistical) accuracy within the clinical range (less then 10 min). This means that ORANGE can be a candidate for a dose engine in radiotherapy treatment planning.
The exchange of radiotherapy data as part of an electronic patient-referral system.
Lomax, A; Grossmann, M; Cozzi, L; Tercier, P A; Boehringer, T; Schneider, U; Logean, M; Volken, W; Ratib, O; Miralbell, R
2000-07-15
To describe the implementation and use of an electronic patient-referral system as an aid to the efficient referral of patients to a remote and specialized treatment center. A system for the exchange of radiotherapy data between different commercial planning systems and a specially developed planning system for proton therapy has been developed through the use of the PAPYRUS diagnostic image standard as an intermediate format. To ensure the cooperation of the different TPS manufacturers, the number of data sets defined for transfer has been restricted to the three core data sets of CT, VOIs, and three-dimensional dose distributions. As a complement to the exchange of data, network-wide application-sharing (video-conferencing) technologies have been adopted to provide methods for the interactive discussion and assessment of treatments plans with one or more partner clinics. Through the use of evaluation plans based on the exchanged data, referring clinics can accurately assess the advantages offered by proton therapy on a patient-by-patient basis, while the practicality or otherwise of the proposed treatments can simultaneously be assessed by the proton therapy center. Such a system, along with the interactive capabilities provided by video-conferencing methods, has been found to be an efficient solution to the problem of patient assessment and selection at a specialized treatment center, and is a necessary first step toward the full electronic integration of such centers with their remotely situated referral centers.
Laschinsky, Lydia; Baumann, Michael; Beyreuther, Elke; Enghardt, Wolfgang; Kaluza, Malte; Karsch, Leonhard; Lessmann, Elisabeth; Naumburger, Doreen; Nicolai, Maria; Richter, Christian; Sauerbrey, Roland; Schlenvoigt, Hans-Peter; Pawelke, Jörg
2012-01-01
The notable progress in laser particle acceleration technology promises potential medical application in cancer therapy through compact and cost effective laser devices that are suitable for already existing clinics. Previously, consequences on the radiobiological response by laser driven particle beams characterised by an ultra high peak dose rate have to be investigated. Therefore, tumour and non-malignant cells were irradiated with pulsed laser accelerated electrons at the JETI facility for the comparison with continuous electrons of a conventional therapy LINAC. Dose response curves were measured for the biological endpoints clonogenic survival and residual DNA double strand breaks. The overall results show no significant differences in radiobiological response for in vitro cell experiments between laser accelerated pulsed and clinical used electron beams. These first systematic in vitro cell response studies with precise dosimetry to laser driven electron beams represent a first step toward the long term aim of the application of laser accelerated particles in radiotherapy.
Amols, Howard I
2008-11-01
New technologies such as intensity modulated and image guided radiation therapy, computer controlled linear accelerators, record and verify systems, electronic charts, and digital imaging have revolutionized radiation therapy over the past 10-15 y. Quality assurance (QA) as historically practiced and as recommended in reports such as American Association of Physicists in Medicine Task Groups 40 and 53 needs to be updated to address the increasing complexity and computerization of radiotherapy equipment, and the increased quantity of data defining a treatment plan and treatment delivery. While new technology has reduced the probability of many types of medical events, seeing new types of errors caused by improper use of new technology, communication failures between computers, corrupted or erroneous computer data files, and "software bugs" are now being seen. The increased use of computed tomography, magnetic resonance, and positron emission tomography imaging has become routine for many types of radiotherapy treatment planning, and QA for imaging modalities is beyond the expertise of most radiotherapy physicists. Errors in radiotherapy rarely result solely from hardware failures. More commonly they are a combination of computer and human errors. The increased use of radiosurgery, hypofractionation, more complex intensity modulated treatment plans, image guided radiation therapy, and increasing financial pressures to treat more patients in less time will continue to fuel this reliance on high technology and complex computer software. Clinical practitioners and regulatory agencies are beginning to realize that QA for new technologies is a major challenge and poses dangers different in nature than what are historically familiar.
Shakespeare, Thomas P
2015-11-18
Positron emission tomography (PET) imaging is routinely used in many cancer types, although is not yet a standard modality for prostate carcinoma. Prostate-specific membrane antigen (PSMA) PET is a promising new modality for staging prostate cancer, with recent studies showing potential advantages over traditional computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine bone scan imaging. However, the impact of PSMA PET on the decision-making of radiation oncologists and outcomes after radiotherapy is yet to be determined. Our aim was to determine the impact of PSMA PET on a radiation oncologist's clinical practice. Patients in a radiation oncology clinic who underwent PSMA PET were prospectively recorded in an electronic oncology record. Patient demographics, outcomes of imaging, and impact on decision-making were evaluated. Fifty-four patients underwent PSMA PET between January and May 2015. The major reasons for undergoing PET included staging before definitive (14.8%) or post-prostatectomy (33.3%) radiotherapy, and investigation of PSA failures following definitive (16.7%) or post-prostatectomy (33.3%) radiotherapy. In 46.3% of patients PSMA was positive after negative traditional imaging, in 9.3% PSMA was positive after equivocal imaging, and in 13.0% PSMA was negative after equivocal imaging. PSMA PET changed radiotherapy management in 46.3% of cases, and hormone therapy in 33.3% of patients, with an overall change in decision-making in 53.7% of patients. PSMA PET has the potential to significantly alter the decision-making of radiation oncologists, and may become a valuable imaging tool in the future.
Kohli, Kirpal; Liu, Jeff; Schellenberg, Devin; Karvat, Anand; Parameswaran, Ash; Grewal, Parvind; Thomas, Steven
2014-10-14
In radiotherapy, temporary translocations of the internal organs and tumor induced by respiratory and cardiac activities can undesirably lead to significantly lower radiation dose on the targeted tumor but more harmful radiation on surrounding healthy tissues. Respiratory and cardiac gated radiotherapy offers a potential solution for the treatment of tumors located in the upper thorax. The present study focuses on the design and development of simultaneous acquisition of respiratory and cardiac signal using electrical impedance technology for use in dual gated radiotherapy. An electronic circuitry was developed for monitoring the bio-impedance change due to respiratory and cardiac motions and extracting the cardiogenic ECG signal. The system was analyzed in terms of reliability of signal acquisition, time delay, and functionality in a high energy radiation environment. The resulting signal of the system developed was also compared with the output of the commercially available Real-time Position Management™ (RPM) system in both time and frequency domains. The results demonstrate that the bioimpedance-based method can potentially provide reliable tracking of respiratory and cardiac motion in humans, alternative to currently available methods. When compared with the RPM system, the impedance-based system developed in the present study shows similar output pattern but different sensitivities in monitoring different respiratory rates. The tracking of cardiac motion was more susceptible to interference from other sources than respiratory motion but also provided synchronous output compared with the ECG signal extracted. The proposed hardware-based implementation was observed to have a worst-case time delay of approximately 33 ms for respiratory monitoring and 45 ms for cardiac monitoring. No significant effect on the functionality of the system was observed when it was tested in a radiation environment with the electrode lead wires directly exposed to high-energy X-Rays. The developed system capable of rendering quality signals for tracking both respiratory and cardiac motions can potentially provide a solution for simultaneous dual-gated radiotherapy.
Zelefsky, Michael J.; Lee, W. Robert; Zietman, Anthony; Khalid, Najma; Crozier, Cheryl; Owen, Jean; Wilson, J. Frank
2012-01-01
Purpose To test the feasibility of using proposed quality indicators to assess radiotherapy quality in prostate cancer management based on a 2007 stratified random survey of treating academic and non-academic US institutions. Methods and Materials 414 patients with clinically localized prostate cancer treated with external beam radiotherapy (EBRT) or brachytherapy were selected from 45 institutions. Indicators used as specific measurable clinical performance measures to represent surrogates for quality of radiotherapy delivery included established measures, such as the use of prescription doses ≥75 Gy for intermediate- and high-risk EBRT patients and androgen-deprivation therapy (ADT) in conjunction with EBRT for patients with high-risk disease, and emerging measures, including daily target localization (image-guidance) to correct for organ motion for EBRT patients. Results 167 patients (47%) were treated with 6 MV photons, 31 (9%) were treated with 10 MV, 65 (18%) received 15 MV, and the remaining 90 (26%) 16–23 MV. For intermediate- plus high-risk patients (n=181), 78% were treated to ≥75 Gy. Among favorable-risk patients, 72% were treated to ≥75 Gy. Among high-risk EBRT patients, 60 (87%) were treated with ADT in conjunction with EBRT and 13% (n=9) with radiotherapy alone. Among low- and intermediate-risk patients, 10% and 42%, respectively, were treated with ADT plus EBRT. For 24% of EBRT patients (85/354), weekly electronic portal imaging was obtained as verification films without daily target localization and the remaining 76% were treated with daily localization of the target using various methods. Conclusions Adherence to defined quality indicators was observed in a majority of patients. ≈90% of high-risk patients are treated with ADT plus EBRT and ≈80% of intermediate- and high-risk patients receive prescription doses >=75 Gy, consistent with the published results of randomized trials. PMID:23471563
Zelefsky, Michael J; Lee, W Robert; Zietman, Anthony; Khalid, Najma; Crozier, Cheryl; Owen, Jean; Wilson, J Frank
2013-01-01
To test the feasibility of using proposed quality indicators to assess radiotherapy quality in prostate cancer management based on a 2007 stratified random survey of treating academic and non-academic US institutions. 414 patients with clinically localized prostate cancer treated with external beam radiotherapy (EBRT) or brachytherapy were selected from 45 institutions. Indicators used as specific measurable clinical performance measures to represent surrogates for quality of radiotherapy delivery included established measures, such as the use of prescription doses ≥75 Gy for intermediate- and high-risk EBRT patients and androgen-deprivation therapy (ADT) in conjunction with EBRT for patients with high-risk disease, and emerging measures, including daily target localization (image-guidance) to correct for organ motion for EBRT patients. 167 patients (47%) were treated with 6 MV photons, 31 (9%) were treated with 10 MV, 65 (18%) received 15 MV, and the remaining 90 (26%) 16-23 MV. For intermediate- plus high-risk patients (n=181), 78% were treated to ≥75 Gy. Among favorable-risk patients, 72% were treated to ≥75 Gy. Among high-risk EBRT patients, 60 (87%) were treated with ADT in conjunction with EBRT and 13% (n=9) with radiotherapy alone. Among low- and intermediate-risk patients, 10% and 42%, respectively, were treated with ADT plus EBRT. For 24% of EBRT patients (85/354), weekly electronic portal imaging was obtained as verification films without daily target localization and the remaining 76% were treated with daily localization of the target using various methods. Adherence to defined quality indicators was observed in a majority of patients. ≈90% of high-risk patients are treated with ADT plus EBRT and ≈80% of intermediate- and high-risk patients receive prescription doses >=75 Gy, consistent with the published results of randomized trials.
Healy, B J; van der Merwe, D; Christaki, K E; Meghzifene, A
2017-02-01
Medical linear accelerators (linacs) and cobalt-60 machines are both mature technologies for external beam radiotherapy. A comparison is made between these two technologies in terms of infrastructure and maintenance, dosimetry, shielding requirements, staffing, costs, security, patient throughput and clinical use. Infrastructure and maintenance are more demanding for linacs due to the complex electric componentry. In dosimetry, a higher beam energy, modulated dose rate and smaller focal spot size mean that it is easier to create an optimised treatment with a linac for conformal dose coverage of the tumour while sparing healthy organs at risk. In shielding, the requirements for a concrete bunker are similar for cobalt-60 machines and linacs but extra shielding and protection from neutrons are required for linacs. Staffing levels can be higher for linacs and more staff training is required for linacs. Life cycle costs are higher for linacs, especially multi-energy linacs. Security is more complex for cobalt-60 machines because of the high activity radioactive source. Patient throughput can be affected by source decay for cobalt-60 machines but poor maintenance and breakdowns can severely affect patient throughput for linacs. In clinical use, more complex treatment techniques are easier to achieve with linacs, and the availability of electron beams on high-energy linacs can be useful for certain treatments. In summary, there is no simple answer to the question of the choice of either cobalt-60 machines or linacs for radiotherapy in low- and middle-income countries. In fact a radiotherapy department with a combination of technologies, including orthovoltage X-ray units, may be an option. Local needs, conditions and resources will have to be factored into any decision on technology taking into account the characteristics of both forms of teletherapy, with the primary goal being the sustainability of the radiotherapy service over the useful lifetime of the equipment. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Sensitivity analysis for dose deposition in radiotherapy via a Fokker–Planck model
Barnard, Richard C.; Frank, Martin; Krycki, Kai
2016-02-09
In this paper, we study the sensitivities of electron dose calculations with respect to stopping power and transport coefficients. We focus on the application to radiotherapy simulations. We use a Fokker–Planck approximation to the Boltzmann transport equation. Equations for the sensitivities are derived by the adjoint method. The Fokker–Planck equation and its adjoint are solved numerically in slab geometry using the spherical harmonics expansion (P N) and an Harten-Lax-van Leer finite volume method. Our method is verified by comparison to finite difference approximations of the sensitivities. Finally, we present numerical results of the sensitivities for the normalized average dose depositionmore » depth with respect to the stopping power and the transport coefficients, demonstrating the increase in relative sensitivities as beam energy decreases. In conclusion, this in turn gives estimates on the uncertainty in the normalized average deposition depth, which we present.« less
Real-time detection of fast and thermal neutrons in radiotherapy with CMOS sensors.
Arbor, Nicolas; Higueret, Stephane; Elazhar, Halima; Combe, Rodolphe; Meyer, Philippe; Dehaynin, Nicolas; Taupin, Florence; Husson, Daniel
2017-03-07
The peripheral dose distribution is a growing concern for the improvement of new external radiation modalities. Secondary particles, especially photo-neutrons produced by the accelerator, irradiate the patient more than tens of centimeters away from the tumor volume. However the out-of-field dose is still not estimated accurately by the treatment planning softwares. This study demonstrates the possibility of using a specially designed CMOS sensor for fast and thermal neutron monitoring in radiotherapy. The 14 microns-thick sensitive layer and the integrated electronic chain of the CMOS are particularly suitable for real-time measurements in γ/n mixed fields. An experimental field size dependency of the fast neutron production rate, supported by Monte Carlo simulations and CR-39 data, has been observed. This dependency points out the potential benefits of a real-time monitoring of fast and thermal neutron during beam intensity modulated radiation therapies.
AutoLock: a semiautomated system for radiotherapy treatment plan quality control
Lowe, Matthew; Hardy, Mark J.; Boylan, Christopher J.; Whitehurst, Philip; Rowbottom, Carl G.
2015-01-01
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock. PACS number: 87.55.Qr PMID:26103498
AutoLock: a semiautomated system for radiotherapy treatment plan quality control.
Dewhurst, Joseph M; Lowe, Matthew; Hardy, Mark J; Boylan, Christopher J; Whitehurst, Philip; Rowbottom, Carl G
2015-05-08
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock.
MAESTRO: Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology
NASA Astrophysics Data System (ADS)
Barthe, Jean; Hugon, Régis; Nicolai, Jean Philippe
2007-12-01
The integrated project MAESTRO (Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology) under contract with the European Commission in life sciences FP6 (LSHC-CT-2004-503564), concerns innovative research to develop and validate in clinical conditions, advanced methods and equipment needed in cancer treatment for new modalities in high-conformal external radiotherapy using electrons, photons and protons beams of high energy.
NASA Astrophysics Data System (ADS)
Alawiah, A.; Intan, A. M.; Bauk, S.; Abdul-Rashid, H. A.; Yusoff, Z.; Mokhtar, M. R.; Wan Abdullah, W. S.; Mat Sharif, K. A.; Mahdiraji, G. A.; Mahamd Adikan, F. R.; Tamchek, N.; Noor, N. M.; Bradley, D. A.
2013-05-01
Thermoluminescence (TL) flat optical fibers (FF) have been proposed as radiation sensor in medical dosimetry for both diagnostic and radiotherapy applications. A flat optical fiber with nominal dimensions of (3.226 × 3.417 × 0.980) mm3 contains pure silica SiO2 was selected for this research. The FF was annealed at 400°C for 1 h before irradiated. Kinetic parameters and dosimetric glow curve of TL response were studied in FF with respect to electron irradiation of 6 MeV, 15 MeV and 21 MeV using linear accelerator (LINAC) in the dose range of 2.0-10.0 Gy. The TL response was read using a TLD reader Harshaw Model 3500. The Time-Temperature-Profile (TTP) of the reader used includes; initial preheat temperature of 80°C, maximum readout temperature is 400°C and the heating rate of 30°Cs-1. The proposed FF shows excellent linear radiation response behavior within the clinical relevant dose range for all of these energies, good reproducibility, independence of radiation energy, independence of dose rate and exhibits a very low thermal fading. From these results, the proposed FF can be used as radiation dosimeter and favorably compares with the widely used of LiF:MgTi dosimeter in medical radiotherapy application.
Dosimetric evaluation of the effect of dental implants in head and neck radiotherapy.
Ozen, Julide; Dirican, Bahar; Oysul, Kaan; Beyzadeoglu, Murat; Ucok, Ozlem; Beydemir, Bedri
2005-06-01
The aim of the study was to examine the dose enhancement from scattered radiation at bone-dental implant interfaces during simulated head and neck radiotherapy. Four cylindrical titanium dental implants with 3 different sizes and lengths were implanted into a human mandible in 4 different positions. Ionization measurements for 6 MV X, 25 MV X, and Co-60 gamma rays were done. Thermoluminescent dosimeter (TLD 100 ) chips were used to measure radiation dose enhancement due to the scattered electrons from titanium and electronic disequilibrium at the tissue-metal interface. The results showed that for Co-60, there is a 21% maximum increase in dose to alveolar mandibular bone at the close proximity to the titanium. For 6-MV x-rays the dose enhancement increase was almost the same or slightly lower than for Co-60, while for 25-MV high-energy x-rays, dose enhancement was lower than that of others. This increase in dose enhancement fell off rapidly and became insignificant at 2 mm from the interface. Total dose that may lead to osteoradionecrosis risk of the mandible is slightly but not significantly affected by the scattered dose of the dental implants of lower jaw in the radiation field exposed to 3 different radiation beams.
Laser-generated bismuth nanoparticles for applications in imaging and radiotherapy
NASA Astrophysics Data System (ADS)
Torrisi, L.; Silipigni, L.; Restuccia, N.; Cuzzocrea, S.; Cutroneo, M.; Barreca, F.; Fazio, B.; Di Marco, G.; Guglielmino, S.
2018-08-01
Bismuth nanoparticles were obtained by laser ablation in water and characterized by using different physical techniques. Their shape, estimated by SEM measurements, was approximately spherical with an average diameter of about 25 nm, and a solution concentration of about 0.8 mg/ml was prepared. The formation of pure Bi nanoparticles was also confirmed by micro-Raman spectra which showed the characteristic first order Raman modes of rhombohedral bismuth. The presence of this phase was also supported by the XRD pattern. The EDX analysis indicated that the as-prepared nanoparticles contained Bi metallic element. The high Z of the nanoparticles in the solution shows effects of surface plasmon resonance in the near ultraviolet and visible regions, high mass absorption coefficient for X-ray interaction and high electronic and nuclear stopping powers for electron and ion beams. Such biocompatible solution can be injected in living systems, such as mice, in order to study the presence of uptake in different organs with high contrast spatial localization in the tissues where Bi nanoparticles are confined. The results indicate that Bi nanoparticles can be employed as high contrast medium for high resolution imaging in biological systems as well as target for exposition to ionizing radiation during radiotherapy or to visible light during hyperthermia of diseased cells.
Small field measurements with a novel silicon position sensitive diode array.
Manolopoulos, S; Wojnecki, C; Hugtenburg, R; Jaafar Sidek, M A; Chalmers, G; Heyes, G; Green, S
2009-02-07
DOSI, a novel dosimeter based on position sensitive detectors for particle physics experiments, was used for relative clinical dosimetry measurements in small radiotherapy fields. The device is capable of dynamic measurements in real time and provides sub-millimetre spatial resolution. The basic beam data for a stereotactic radiotherapy collimator system (BrainLAB) using 6 MV photons were measured and compared with the corresponding data acquired with a small diamond detector and a PinPoint ionization chamber. All measurements showed an excellent agreement between DOSI and the diamond detector. There was an increasing discrepancy between the relative output factors (ROF) measured with DOSI and those measured with the ionization chamber with decreasing field size, specifically for collimators with a diameter smaller than 15 mm. The percentage depth doses (PDD) were in agreement to better than 1% for all depths. The agreement on off-axis ratios (OAR) was better than 3% for all collimators, whereas the agreement on relative output factors (ROF) was at the 1% level. DOSI's fast read-out electronics made it possible for all measurements to be recorded within 45 min including time to change collimators. This should reduce the overall time for commissioning and QA measurements, an important factor especially for busy radiotherapy departments.
de Barros da Cunha, Sandra Ribeiro; Fonseca, Felipe Paiva; Ramos, Pedro Augusto Minorin Mendes; Haddad, Cecília Maria Kalil; Fregnani, Eduardo Rodrigues; Aranha, Ana Cecília Corrêa
2017-08-01
To evaluate the effects of three different radiotherapy doses (20, 40, and 70Gy) on the microhardness, superficial morphology, and mineral content (based on Ca and P values) of three different depths of human enamel (cervical, middle, and occlusal). Thirty-four third molars were cut, separated, and prepared. Microhardness samples (n=30) were embedded in acrylic resin and then polished, and depths were delimited. Microhardness tests were performed on cervical, middle, and occlusal enamel pre- and post-radiotherapy with a load of 50g for 30s. For the scanning electron microscopy (SEM) analysis (n=4) and energy dispersive X-ray spectroscopy (EDS) (n=12), samples were fixed in a 3% glutaraldehyde solution, washed in 0.1M cacodylate solution, and dehydrated in crescent concentrations of ethanol. Microhardness data were tested for significant differences using a two-way analysis of variance (ANOVA) and Tukey's test (p<0.05), while SEM and EDS were evaluated qualitatively. The results showed a decrease in microhardness values only in the cervical enamel, regardless of the radiation dose used; no morphological or mineral change was observed. Radiotherapy can affect the microhardness values of only cervical enamel without compromising the morphological or mineral (Ca and P) content at any depth. Copyright © 2017 Elsevier Ltd. All rights reserved.
Koetsenruijter, K. W. J.; Swan, K.; Bogaardt, H.
2016-01-01
Introduction. Patients with head and neck cancer suffer from various impairments due to the primary illness, as well as secondary consequences of the oncological treatment. This systematic review describes the effects of radiotherapy and/or chemotherapy on the functions of the upper aerodigestive tract in patients with head and neck cancer. Methods. A systematic literature search was performed by two independent reviewers using the electronic databases PubMed and Embase. All dates up to May 2016 were included. Results. Of the 947 abstracts, sixty articles met the inclusion criteria and described one or more aspects of the sequelae of radiotherapy and/or chemotherapy. Forty studies described swallowing-related problems, 24 described voice-related problems, seven described trismus, and 25 studies described general quality of life. Only 14 articles reported that speech pathologists conducted the interventions, of which only six articles described in detail what the interventions involved. Conclusion. In general, voice quality improved following intervention, whereas quality of life, dysphagia, and oral intake deteriorated during and after treatment. However, as a consequence of the diversity in treatment protocols and patient characteristics, the conclusions of most studies cannot be easily generalised. Further research on the effects of oncological interventions on the upper aerodigestive tract is needed. PMID:27722170
NASA Astrophysics Data System (ADS)
Tang, Xiaoli; Lin, Tong; Jiang, Steve
2009-09-01
We propose a novel approach for potential online treatment verification using cine EPID (electronic portal imaging device) images for hypofractionated lung radiotherapy based on a machine learning algorithm. Hypofractionated radiotherapy requires high precision. It is essential to effectively monitor the target to ensure that the tumor is within the beam aperture. We modeled the treatment verification problem as a two-class classification problem and applied an artificial neural network (ANN) to classify the cine EPID images acquired during the treatment into corresponding classes—with the tumor inside or outside of the beam aperture. Training samples were generated for the ANN using digitally reconstructed radiographs (DRRs) with artificially added shifts in the tumor location—to simulate cine EPID images with different tumor locations. Principal component analysis (PCA) was used to reduce the dimensionality of the training samples and cine EPID images acquired during the treatment. The proposed treatment verification algorithm was tested on five hypofractionated lung patients in a retrospective fashion. On average, our proposed algorithm achieved a 98.0% classification accuracy, a 97.6% recall rate and a 99.7% precision rate. This work was first presented at the Seventh International Conference on Machine Learning and Applications, San Diego, CA, USA, 11-13 December 2008.
Electron Density Calibration for Radiotherapy Treatment Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herrera-Martinez, F.; Rodriguez-Villafuerte, M.; Martinez-Davalos, A.
2006-09-08
Computed tomography (CT) images are used as basic input data for most modern radiosurgery treatment planning systems (TPS). CT data not only provide anatomic information to delineate target volumes, but also allow the introduction of corrections for tissue inhomogeneities into dose calculations during the treatment planning procedure. These corrections involve the determination of a relationship between tissue electron density ({rho}e) and their corresponding Hounsfield Units (HU). In this work, an elemental analysis of different commercial tissue equivalent materials using Scanning Electron Microscopy was carried out to characterize their chemical composition. The tissue equivalent materials were chosen to ensure a largemore » range of {rho}e to be included in the CT scanner calibration. A phantom was designed and constructed with these materials to simulate the size of a human head.« less
Implementation of an intraoperative electron radiotherapy in vivo dosimetry program.
López-Tarjuelo, Juan; Morillo-Macías, Virginia; Bouché-Babiloni, Ana; Boldó-Roda, Enrique; Lozoya-Albacar, Rafael; Ferrer-Albiach, Carlos
2016-03-15
Intraoperative electron radiotherapy (IOERT) is a highly selective radiotherapy technique which aims to treat restricted anatomic volumes during oncological surgery and is now the subject of intense re-evaluation. In vivo dosimetry has been recommended for IOERT and has been identified as a risk-reduction intervention in the context of an IOERT risk analysis. Despite reports of fruitful experiences, information about in vivo dosimetry in intraoperative radiotherapy is somewhat scarce. Therefore, the aim of this paper is to report our experience in developing a program of in vivo dosimetry for IOERT, from both multidisciplinary and practical approaches, in a consistent patient series. We also report several current weaknesses. Reinforced TN-502RDM-H mobile metal oxide semiconductor field effect transistors (MOSFETs) and Gafchromic MD-55-2 films were used as a redundant in vivo treatment verification system with an Elekta Precise fixed linear accelerator for calibrations and treatments. In vivo dosimetry was performed in 45 patients in cases involving primary tumors or relapses. The most frequent primary tumors were breast (37 %) and colorectal (29 %), and local recurrences among relapses was 83 %. We made 50 attempts to measure with MOSFETs and 48 attempts to measure with films in the treatment zones. The surgical team placed both detectors with supervision from the radiation oncologist and following their instructions. The program was considered an overall success by the different professionals involved. The absorbed doses measured with MOSFETs and films were 93.8 ± 6.7 % and 97.9 ± 9.0 % (mean ± SD) respectively using a scale in which 90 % is the prescribed dose and 100 % is the maximum absorbed dose delivered by the beam. However, in 10 % of cases we experienced dosimetric problems due to detector misalignment, a situation which might be avoided with additional checks. The useful MOSFET lifetime length and the film sterilization procedure should also be controlled. It is feasible to establish an in vivo dosimetry program for a wide set of locations treated with IOERT using a multidisciplinary approach according to the skills of the professionals present and the detectors used; oncological surgeons' commitment is key to success in this context. Films are more unstable and show higher uncertainty than MOSFETs but are cheaper and are useful and convenient if real-time treatment monitoring is not necessary.
El Shafie, Rami A; Bougatf, Nina; Sprave, Tanja; Weber, Dorothea; Oetzel, Dieter; Machmer, Timo; Huber, Peter E; Debus, Jürgen
2018-01-01
Background The increasing role of consumer electronics and Web-enabled mobile devices in the medical sector opens up promising possibilities for integrating novel technical solutions into therapy and patient support for oncologic illnesses. A recent survey carried out at Heidelberg University Hospital suggested a high acceptance among patients for an additional approach to patient care during radiotherapy based on patient-reported outcomes by a dedicated mobile app. Objective The aim of this trial (OPTIMISE-1: Oncologic Therapy Support Via Means of a Dedicated Mobile App – A Prospective Feasibility Evaluation) is to prospectively evaluate the feasibility of employing a mobile app for the systematic support of radiooncological patients throughout the course of their radiotherapy by monitoring symptoms and patient performance, and facilitating the background-exchange of relevant information between patient and physician. Methods The present single-center, prospective, exploratory trial, conducted at Heidelberg University Hospital, assesses the feasibility of integrating an app-based approach into patient-care during radiotherapy. Patients undergoing curative radiotherapy for thoracic or pelvic tumors will be surveyed regarding general performance, treatment-related quality of life (QoL) and symptoms, and their need to personally consult a physician by means of a mobile app during treatment. The primary endpoint of feasibility will be reached when 80% of the patients have successfully answered 80% of their respective questions scheduled for each treatment day. Furthermore, treatment-related patient satisfaction and health-related QoL is assessed by the Patient Satisfaction Questionnaire Short Form (PSQ-18) and the European Organization for Research and Treatment of Cancer (EORTC) questionnaires at the beginning (baseline) and end of radiotherapy, and at the first follow-up. Results This trial will recruit 50 patients over a period of 12 months. Follow-up will be completed after 18 months, and publication of results is planned at 24 months after trial initiation. Conclusions This study will serve as a basis for future studies aiming to exploit the constant innovation in mobile medical appliances and integrate novel patient-centered concepts into patient care in the context of radiotherapy. Trial Registration ClinicalTrials.gov NCT03168048; https://clinicaltrials.gov/ct2/show/NCT03168048 (Archived at WebCite http://www.webcitation.org/6wtWGgi0X) PMID:29510971
Monte Carlo based electron treatment planning and cutout output factor calculations
NASA Astrophysics Data System (ADS)
Mitrou, Ellis
Electron radiotherapy (RT) offers a number of advantages over photons. The high surface dose, combined with a rapid dose fall-off beyond the target volume presents a net increase in tumor control probability and decreases the normal tissue complication for superficial tumors. Electron treatments are normally delivered clinically without previously calculated dose distributions due to the complexity of the electron transport involved and greater error in planning accuracy. This research uses Monte Carlo (MC) methods to model clinical electron beams in order to accurately calculate electron beam dose distributions in patients as well as calculate cutout output factors, reducing the need for a clinical measurement. The present work is incorporated into a research MC calculation system: McGill Monte Carlo Treatment Planning (MMCTP) system. Measurements of PDDs, profiles and output factors in addition to 2D GAFCHROMICRTM EBT2 film measurements in heterogeneous phantoms were obtained to commission the electron beam model. The use of MC for electron TP will provide more accurate treatments and yield greater knowledge of the electron dose distribution within the patient. The calculation of output factors could invoke a clinical time saving of up to 1 hour per patient.
Real-time simulator for designing electron dual scattering foil systems.
Carver, Robert L; Hogstrom, Kenneth R; Price, Michael J; LeBlanc, Justin D; Pitcher, Garrett M
2014-11-08
The purpose of this work was to develop a user friendly, accurate, real-time com- puter simulator to facilitate the design of dual foil scattering systems for electron beams on radiotherapy accelerators. The simulator allows for a relatively quick, initial design that can be refined and verified with subsequent Monte Carlo (MC) calculations and measurements. The simulator also is a powerful educational tool. The simulator consists of an analytical algorithm for calculating electron fluence and X-ray dose and a graphical user interface (GUI) C++ program. The algorithm predicts electron fluence using Fermi-Eyges multiple Coulomb scattering theory with the reduced Gaussian formalism for scattering powers. The simulator also estimates central-axis and off-axis X-ray dose arising from the dual foil system. Once the geometry of the accelerator is specified, the simulator allows the user to continuously vary primary scattering foil material and thickness, secondary scat- tering foil material and Gaussian shape (thickness and sigma), and beam energy. The off-axis electron relative fluence or total dose profile and central-axis X-ray dose contamination are computed and displayed in real time. The simulator was validated by comparison of off-axis electron relative fluence and X-ray percent dose profiles with those calculated using EGSnrc MC. Over the energy range 7-20 MeV, using present foils on an Elekta radiotherapy accelerator, the simulator was able to reproduce MC profiles to within 2% out to 20 cm from the central axis. The central-axis X-ray percent dose predictions matched measured data to within 0.5%. The calculation time was approximately 100 ms using a single Intel 2.93 GHz processor, which allows for real-time variation of foil geometrical parameters using slider bars. This work demonstrates how the user-friendly GUI and real-time nature of the simulator make it an effective educational tool for gaining a better understanding of the effects that various system parameters have on a relative dose profile. This work also demonstrates a method for using the simulator as a design tool for creating custom dual scattering foil systems in the clinical range of beam energies (6-20 MeV).
Saito, Masatoshi
2009-08-01
Dual-energy computed tomography (DECT) has the potential for measuring electron density distribution in a human body to predict the range of particle beams for treatment planning in proton or heavy-ion radiotherapy. However, thus far, a practical dual-energy method that can be used to precisely determine electron density for treatment planning in particle radiotherapy has not been developed. In this article, another DECT technique involving a balanced filter method using a conventional x-ray tube is described. For the spectral optimization of DECT using balanced filters, the author calculates beam-hardening error and air kerma required to achieve a desired noise level in electron density and effective atomic number images of a cylindrical water phantom with 50 cm diameter. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. The optimized parameters were applied to cases with different phantom diameters ranging from 5 to 50 cm for the calculations. The author predicts that the optimal combination of tube voltages would be 80 and 140 kV with Tb/Hf and Bi/Mo filter pairs for the 50-cm-diameter water phantom. When a single phantom calibration at a diameter of 25 cm was employed to cover all phantom sizes, maximum absolute beam-hardening errors were 0.3% and 0.03% for electron density and effective atomic number, respectively, over a range of diameters of the water phantom. The beam-hardening errors were 1/10 or less as compared to those obtained by conventional DECT, although the dose was twice that of the conventional DECT case. From the viewpoint of beam hardening and the tube-loading efficiency, the present DECT using balanced filters would be significantly more effective in measuring the electron density than the conventional DECT. Nevertheless, further developments of low-exposure imaging technology should be necessary as well as x-ray tubes with higher outputs to apply DECT coupled with the balanced filter method for clinical use.
Shahid, Negin; Craig, Timothy; Westerland, Mary; Ashworth, Allison; Ang, Michelle; D'Souza, David; Sankreacha, Raxa; Fyles, Anthony; Milosevic, Michael; Kong, Iwa
2018-04-19
To recognize the practice of radiotherapy for management of cervical cancer in Ontario, Canada, and to use the results of the survey to harmonize and standardize practice across the province. An electronic survey (SurveyMonkey) was sent to all 14 provincial cancer centers by Cancer Care Ontario Gynecology Community of Practice (CoP) in 2013. The survey included 72 questions in four different categories: general/demographic, pretreatment assessment, external beam radiotherapy (EBRT), and brachytherapy (BT). Ten of 14 centers treated cervical cancer patients and had a dedicated BT suite. All 10 centers had a peer review process for quality assurance. EBRT technique was a 4-field box in eight of 10 centers. The dose/fractionation for pelvic EBRT was 45-50 Gy in 1.8-2 Gy/fraction in all but one center. Nine of 10 centers used high-dose-rate BT. Only one center offered interstitial BT. For treatment planning, two centers used CT and MRI, five centers used CT, and three centers used orthogonal x-rays. Groupe Européen de Curiethérapie and the European Society for Radiotherapy & Oncology guidelines were used in four of seven of the centers for target volume delineation and in five of seven centers for organs at risk dose constraints. All but one center prescribed and reported dose to Point A. The survey identified areas where practice varied across the province. Gynecology CoP used this information to identify priorities for practice change and implemented several strategies to harmonize the care of women with cervical cancer. This highlights the value of interdisciplinary, grass-roots initiatives such as CoPs to standardize practice in a practical manner that directly benefits patients. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic.
Kroutilķková, Daniela; Novotný, Josef; Judas, Libor
2003-02-01
The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of +/-3% are considered acceptable for both basic and advanced mode of the audit. There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres.
Kimyon, Gunsu; Turan, Taner; Basaran, Derman; Turkmen, Osman; Karalok, Alper; Tasci, Tolga; Tulunay, Gokhan; Kose, Mehmet Faruk
2017-02-01
The aim of this study was to evaluate the treatment options and post-brain involvement survival (PBIS) of patients with isolated brain involvement from endometrial cancer (EC). The literature electronic search was conducted from 1972 to May 2016 to identify articles about isolated (without extracranial metastases) brain involvement from EC at recurrence and the initial diagnosis. Forty-eight articles were found. After comprehensive evaluation of case series and case reports, the study included 49 cases. The median age of the patients at initial diagnosis was 57 years (range, 40-77 years). Poor differentiation was determined in 36 (73.5%) patients. Thirty-five (71.4%) patients had a single brain lesion. Lesion was found in the supratentorial part of the brain in 33 (67.3%) patients. Median PBIS for all cohorts was 13 months (range, 0.25-118 months) with 2-year PBIS of 52% and 5-year PBIS of 37%. Age, tumor type, grade, disease-free interval, diagnosis time of brain lesion, localization, and number of brain lesion were not predictive of PBIS. Two-year PBIS was 77% in patients who underwent surgical resection and radiotherapy, whereas it was 19% in the surgical resection-only group, and 20% in the primary radiotherapy-only group (Ps = 0.003 and 0.001, respectively). Chemotherapy was not associated with improved PBIS. Although neuroinvasion from EC appears mostly with a disseminated disease, there is a considerable amount of patients with isolated brain involvement who would have a higher chance of curability. Surgery with radiotherapy is the rational current management option, and this improves the survival for isolated brain involvement from EC.
The impact of introducing intensity modulated radiotherapy into routine clinical practice.
Miles, Elizabeth A; Clark, Catharine H; Urbano, M Teresa Guerrero; Bidmead, Margaret; Dearnaley, David P; Harrington, Kevin J; A'Hern, Roger; Nutting, Christopher M
2005-12-01
Intensity modulated radiotherapy (IMRT) at the Royal Marsden Hospital London was introduced in July 2001. Treatment delivery was dynamic using a single-phase technique. Concerns were raised regarding increased clinical workload due to introduction of new technology. The potential increased use of resources was assessed. IMRT patient selection was within guidelines of clinical trials and included patients undergoing prostate plus pelvic lymph node (PPN) irradiation and head and neck cancer (HNC) treatment. Patient planning, quality assurance and treatment times were collected for an initial IMRT patient group. A comparative group of patients with advanced HNC undergoing two- or three-phase conventional radiotherapy, requiring matched photon and electron fields, were also timed. The median overall total planning time for IMRT was greater for HNC patients compared to the PPN cohort. For HNC the overall IMRT planning time was significantly longer than for conventional. The median treatment time for conventional two- or three-phase HNC treatments, encompassing similar volumes to those treated with IMRT, was greater than that for the IMRT HNC patient cohort. A reduction in radiographer man hours per patient of 4.8h was recorded whereas physics time was increased by 4.9h per patient. IMRT currently increases overall planning time. Additional clinician input is required for target volume localisation. Physics time is increased, a significant component of this being patient specific QA. Radiographer time is decreased. For HNC a single phase IMRT treatment has proven to be more efficient than a multiple phase conventional treatment. IMRT has been integrated smoothly and efficiently into the existing treatment working day. This preliminary study suggests that IMRT could be a routine treatment with efficient use of current radiotherapy resources.
Intraoperative Radiotherapy for Parotid Cancer: A Single-Institution Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeidan, Youssef H., E-mail: youssefzaidan@gmail.com; Shiue, Kevin; Weed, Daniel
2012-04-01
Purpose: Our practice policy has been to provide intraoperative radiotherapy (IORT) at resection to patients with head-and-neck malignancies considered to be at high risk of recurrence. The purpose of the present study was to review our experience with the use of IORT for primary or recurrent cancer of the parotid gland. Methods and Materials: Between 1982 and 2007, 96 patients were treated with gross total resection and IORT for primary or recurrent cancer of the parotid gland. The median age was 62.9 years (range, 14.3-88.1). Of the 96 patients, 33 had previously undergone external beam radiotherapy as a component ofmore » definitive therapy. Also, 34 patients had positive margins after surgery, and 40 had perineural invasion. IORT was administered as a single fraction of 15 or 20 Gy with 4-6-MeV electrons. The median follow-up period was 5.6 years. Results: Only 1 patient experienced local recurrence, 19 developed regional recurrence, and 12 distant recurrence. The recurrence-free survival rate at 1, 3, and 5 years was 82.0%, 68.5%, and 65.2%, respectively. The 1-, 3-, and 5-year overall survival rate after surgery and IORT was 88.4%, 66.1%, and 56.2%, respectively. No perioperative fatalities occurred. Complications developed in 26 patients and included vascular complications in 7, trismus in 6, fistulas in 4, radiation osteonecrosis in 4, flap necrosis in 2, wound dehiscence in 2, and neuropathy in 1. Of these 26 patients, 12 had recurrent disease, and 8 had undergone external beam radiotherapy before IORT. Conclusions: IORT results in effective local disease control at acceptable levels of toxicity and should be considered for patients with primary or recurrent cancer of the parotid gland.« less
Morris, K
2017-06-01
The dose of radiotherapy is often verified by measuring the dose of radiation at specific points within a phantom. The presence of high-density implant materials such as titanium, however, may cause complications both during calculation and delivery of the dose. Numerous studies have reported photon/electron backscatter and alteration of the dose by high-density implants, but we know of no evidence of a dosimetry phantom that incorporates high density implants or fixtures. The aim of the study was to design and manufacture a tissue-equivalent head phantom for use in verification of the dose in radiotherapy using a combination of traditional laboratory materials and techniques and 3-dimensional technology that can incorporate titanium maxillofacial devices. Digital designs were used together with Mimics® 18.0 (Materialise NV) and FreeForm® software. DICOM data were downloaded and manipulated into the final pieces of the phantom mould. Three-dimensional digital objects were converted into STL files and exported for additional stereolithography. Phantoms were constructed in four stages: material testing and selection, design of a 3-dimensional mould, manufacture of implants, and final fabrication of the phantom using traditional laboratory techniques. Three tissue-equivalent materials were found and used to successfully manufacture a suitable phantom with interchangeable sections that contained three versions of titanium maxillofacial implants. Maxillofacial and other materials can be used to successfully construct a head phantom with interchangeable titanium implant sections for use in verification of doses of radiotherapy. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
WE-B-BRD-00: MRI for Radiation Oncology
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptivemore » QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.« less
SU-F-T-479: Estimation of the Accuracy in Respiratory-Gated Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurosawa, T; Miyakawa, S; Sato, M
Purpose: Irregular respiratory patterns affects dose outputs in respiratorygated radiotherapy and there is no commercially available quality assurance (QA) system for it. We designed and developed a patient specific QA system for respiratory-gated radiotherapy to estimate irradiated output. Methods: Our in-house QA system for gating was composed of a personal computer with the USB-FSIO electronic circuit connecting to the linear accelerator (ONCOR-K, Toshiba Medical Systems). The linac implements a respiratory gating system (AZ-733V, Anzai Medical). During the beam was on, 4.2 V square-wave pulses were continually sent to the system. Our system can receive and count the pulses. At first,more » our system and an oscilloscope were compared to check the performance of our system. Next, basic estimation models were generated when ionization-chamber measurements were performed in gating using regular sinusoidal wave patterns (2.0, 2.5, 4.0, 8.0, 15 sec/cycle). During gated irradiation with the regular patterns, the number of the pulses per one gating window was measured using our system. Correlation between the number of the pulses per one gating and dose per the gating window were assessed to generate the estimation model. Finally, two irregular respiratory patterns were created and the accuracy of the estimation was evaluated. Results: Compared to the oscilloscope, our system worked similarly. The basic models were generated with the accuracy within 0.1%. The results of the gated irradiations with two irregular respiratory patterns show good agreement within 0.4% estimation accuracy. Conclusion: Our developed system shows good estimation for even irregular respiration patterns. The system would be a useful tool to verify the output for respiratory-gated radiotherapy.« less
Shaw, Stephanie M; Flowers, Heather; O'Sullivan, Brian; Hope, Andrew; Liu, Louis W C; Martino, Rosemary
2015-04-01
Patients undergoing radiotherapy for head and neck cancer (HNC) often experience malnutrition and dehydration during treatment. As a result, some centres place PEG tubes prophylactically (pPEG) to prevent these negative consequences. However, recent research has suggested that pPEG use may negatively affect swallowing physiology, function and/or quality of life, especially in the long term. The purpose of this study was to systematically review the literature on pPEG use in HNC patients undergoing radiotherapy and to determine its impact on swallowing-related outcomes. The following electronic databases were searched for all relevant primary research published through February 24, 2014: AMED, CINAHL, the Cochrane Library, Embase, Healthstar, Medline, and PsycINFO. Main search terms included HNC, radiotherapy, deglutition disorders, feeding tube(s), and prophylactic or elective. References for all accepted papers were hand searched to identify additional relevant research. Methodological quality was assessed using Cochrane's Risk of Bias. At all levels, two blinded raters provided judgments. Discrepancies were resolved by consensus. The search retrieved 181 unique citations. Twenty studies met our inclusion criteria. Quality assessment revealed that all studies were at risk for bias due to non-randomized sampling and unreported or inadequate blinding. Ten studies demonstrated selection bias with significant baseline differences between pPEG patients and controls. Results regarding the frequency and severity of dysphagia and swallowing-related outcomes were varied and inconclusive. The impact of pPEG use on swallowing and swallowing-related outcomes remains unclear. Well-controlled, randomized trials are needed to determine if pPEG places patients at greater risk for developing long-term dysphagia.
SU-E-T-279: A Novel Electron-Beam Combined with Magnetic Field Application for Radiotherapy.
Alezra, D; Nardi, E; Koren, S; Bragilovski, D; Orion, I
2012-06-01
The new beam and delivery system consists of an electron accelerator and a system of magnets (one or more). Introducing a transverse magnetic field in and near the tumor, causes the electrons to spiral in this region, thereby producing an effective peak in the depth dose distribution, within the tumor volume. Although the basic idea is not new, we suggest here for the first time, a viable as well as a workable, magnetic field configuration, which in addition to focusing the beam does not interfere with its propagation to the target. The electron accelerator: can be a linear accelerator or any other type electron accelerator, capable of producing different electron energies for different depths and dose absorption accumulation. The Field size can be as small as a pencil beam and as big as any of the other standard field sizes that are used in radiotherapy. The scatter filter can be used or removed. The dose rate accumulation can be as higher as possible.The magnets are able to produce magnetic fields. The order, direction, width, place, shape and number of the magnetic fields define the shape and the Percentage Depth Dose (PDD) curve of the electron beam. Prototypes were successfully tested by means of computer simulation, using:COMSOL-Multiphsics for magnetic fields calculations. FLUKA package, for electron beam MC simulation. Our results suggest that by using an electron beam at different energies, combined with magnetic fields, we could modify the delivered dose. This is caused by manipulating the electron motion via the Lorentz force. The applied magnetic field, will focus the electron beam at a given depth and deposit the energy in a given volume and depth, where otherwise the electron energy will have spread deeper. The direction and magnitude of the magnetic fields will prevent the scattering of the electron beam and its absorption in remote volumes. In practice, we get a pseudo Bragg peak depth dose distribution, applying a relatively low cost system. The therapeutic efficiency induced by the system is of similar efficiency as the ion beam therapy techniques. Our novel concept demonstrates treatment that is almost similar to proton therapy and in some parameters even better performance.Unlike the current high-energy electron therapy, our system's beam deposit almost all of its energy on its target, with a low amount of radiation deposited in tissues from the surface of the skin to the front of tumor, and almost no "exit dose" beyond the tumor. This property will enables to hit tumors with higher, potentially more effective radiation doses, while being considerably less expensive. © 2012 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ibanez-Rosello, B; Bautista-Ballesteros, J; Bonaque, J
2016-06-15
Purpose: Total Skin Electron Irradiation (TSEI) is a radiotherapy treatment which involves irradiating the entire body surface as homogeneously as possible. It is composed of an extensive multi-step technique in which quality management requires high consumption of resources and a fluid communication between the involved staff, necessary to improve the safety of treatment. The TG-100 proposes a new perspective of quality management in radiotherapy, presenting a systematic method of risk analysis throughout the global flow of the stages through the patient. The purpose of this work has been to apply TG-100 approach to the TSEI procedure in our institution. Methods:more » A multidisciplinary team specifically targeting TSEI procedure was formed, that met regularly and jointly developed the process map (PM), following TG-100 guidelines of the AAPM. This PM is a visual representation of the temporal flow of steps through the patient since start until the end of his stay in the radiotherapy service. Results: This is the first stage of the full risk analysis, which is being carried out in the center. The PM provides an overview of the process and facilitates the understanding of the team members who will participate in the subsequent analysis. Currently, the team is implementing the analysis of failure modes and effects (FMEA). The failure modes of each of the steps have been identified and assessors are assigning a value of severity (S), frequency of occurrence (O) and lack of detection (D) individually. To our knowledge, this is the first PM made for the TSEI. The developed PM can be useful for those centers that intend to implement the TSEI technique. Conclusion: The PM of TSEI technique has been established, as the first stage of full risk analysis, performed in a reference center in this treatment.« less
SU-E-T-223: Computed Radiography Dose Measurements of External Radiotherapy Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aberle, C; Kapsch, R
2015-06-15
Purpose: To obtain quantitative, two-dimensional dose measurements of external radiotherapy beams with a computed radiography (CR) system and to derive volume correction factors for ionization chambers in small fields. Methods: A commercial Kodak ACR2000i CR system with Kodak Flexible Phosphor Screen HR storage foils was used. Suitable measurement conditions and procedures were established. Several corrections were derived, including image fading, length-scale corrections and long-term stability corrections. Dose calibration curves were obtained for cobalt, 4 MV, 8 MV and 25 MV photons, and for 10 MeV, 15 MeV and 18 MeV electrons in a water phantom. Inherent measurement inhomogeneities were studiedmore » as well as directional dependence of the response. Finally, 2D scans with ionization chambers were directly compared to CR measurements, and volume correction factors were derived. Results: Dose calibration curves (0.01 Gy to 7 Gy) were obtained for multiple photon and electron beam qualities. For each beam quality, the calibration curves can be described by a single fit equation over the whole dose range. The energy dependence of the dose response was determined. The length scale on the images was adjusted scan-by-scan, typically by 2 percent horizontally and by 3 percent vertically. The remaining inhomogeneities after the system’s standard calibration procedure were corrected for. After correction, the homogeneity is on the order of a few percent. The storage foils can be rotated by up to 30 degrees without a significant effect on the measured signal. First results on the determination of volume correction factors were obtained. Conclusion: With CR, quantitative, two-dimensional dose measurements with a high spatial resolution (sub-mm) can be obtained over a large dose range. In order to make use of these advantages, several calibrations, corrections and supporting measurements are needed. This work was funded by the European Metrology Research Programme (EMRP) project HLT09 MetrExtRT Metrology for Radiotherapy using Complex Radiation Fields.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oborn, B; Ge, Y; Hardcastle, N
Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: 9 clinical lung plans were recalculated using Monte Carlo methods and external inline (parallel to the beam direction) magnetic fields of 0.5 T, 1.0 T and 3 T were included. Three plans were 6MV 3D-CRT and six were 6MV IMRT. The GTV’s ranged from 0.8 cc to 73 cc, while the PTV ranged from 1 cc to 180 cc. Results: The inline magnetic field has a moderatemore » impact in lung dose distributions by reducing the lateral scatter of secondary electrons and causing a small local dose increase. Superposition of multiple small beams acts to superimpose the small dose increases and can lead to significant dose enhancements, especially when the GTV is low density. Two plans with very small, low mean density GTV’s (<1 cc, ρ(mean)<0.35g/cc) showed uniform increases of 16% and 23% at 1 T throughout the PTV. Three plans with moderate mean density PTV’s (3–13 cc, ρ(mean)=0.58–0.67 g/cc) showed 6% mean dose enhancement at 1 T in the PTV, however not uniform throughout the GTV/PTV. Replanning would benefit these cases. The remaining 5 plans had large dense GTV’s (∼ 1 g/cc) and so only a minimal (<2%) enhancement was seen. In general the mean dose enhancement at 0.5 T was 60% less than 1 T, while 5–50% higher at 3 T. Conclusions: A paradigm shift in the efficacy of small lung tumor radiotherapy is predicted with future inline MRI-linac systems. This will be achieved by carefully taking advantage of the reduction of lateral electronic disequilibrium withing lung tissue that is induced naturally inside strong inline magnetic fields.« less
Temporal stability of music perception and appraisal scores of adult cochlear implant recipients.
Gfeller, Kate; Jiang, Dingfeng; Oleson, Jacob J; Driscoll, Virginia; Knutson, John F
2010-01-01
An extensive body of literature indicates that cochlear implants (CIs) are effective in supporting speech perception of persons with severe to profound hearing losses who do not benefit to any great extent from conventional hearing aids. Adult CI recipients tend to show significant improvement in speech perception within 3 mo following implantation as a result of mere experience. Furthermore, CI recipients continue to show modest improvement as long as 5yr postimplantation. In contrast, data taken from single testing protocols of music perception and appraisal indicate that CIs are less than ideal in transmitting important structural features of music, such as pitch, melody, and timbre. However, there is presently little information documenting changes in music perception or appraisal over extended time as a result of mere experience. This study examined two basic questions: (1) Do adult CI recipients show significant improvement in perceptual acuity or appraisal of specific music listening tasks when tested in two consecutive years? (2) If there are tasks for which CI recipients show significant improvement with time, are there particular demographic variables that predict those CI recipients most likely to show improvement with extended CI use? A longitudinal cohort study. Implant recipients return annually for visits to the clinic. The study included 209 adult cochlear implant recipients with at least 9 mo implant experience before their first year measurement. Outcomes were measured on the patient's annual visit in two consecutive years. Paired t-tests were used to test for significant improvement from one year to the next. Those variables demonstrating significant improvement were subjected to regression analyses performed to detect the demographic variables useful in predicting said improvement. There were no significant differences in music perception outcomes as a function of type of device or processing strategy used. Only familiar melody recognition (FMR) and recognition of melody excerpts with lyrics (MERT-L) showed significant improvement from one year to the next. After controlling for the baseline value, hearing aid use, months of use, music listening habits after implantation, and formal musical training in elementary school were significant predictors of FMR improvement. Bilateral CI use, formal musical training in high school and beyond, and a measure of sequential cognitive processing were significant predictors of MERT-L improvement. These adult CI recipients as a result of mere experience demonstrated fairly consistent music perception and appraisal on measures gathered in two consecutive years. Gains made tend to be modest, and can be associated with characteristics such as use of hearing aids, listening experiences, or bilateral use (in the case of lyrics). These results have implications for counseling of CI recipients with regard to realistic expectations and strategies for enhancing music perception and enjoyment.
Platoni, Kalliopi; Diamantopoulos, Stefanos; Dilvoi, Maria; Delinikolas, Panagiotis; Kypraiou, Efrosyni; Efstathopoulos, Efstathios; Kouloulias, Vassilis
2018-01-01
Kaposi's sarcoma (KS) is a systemic neoplastic disease that can present cutaneous symptoms and is usually treated with a systematic approach due to its extent. Due to its radiosensitivity, radiotherapy is considered one of its main treatments, for palliation and local control of the skin and mucosal lesions. The aim of this paper was to report the first case of KS treated by hemi-body electron irradiation protocol in Greece. A fractionated 40 Gy hemi-body electron irradiation was prescribed to a 60-year-old male patient with KS at his legs. Dose uniformity was verified on a daily basis by thermoluminescence dosimetry (TLD). The treatment resulted to complete clinical response. Limited irradiation-derived side effects appeared. This is the first case ever to be treated with hemi-body electron irradiation protocol in Greece. To the best of our knowledge, this is also the first time that a single field hemi-body electron beam irradiation at a total skin electron beam (TSEB)-like configuration is reported to be used for KS.
Optimisation of 12 MeV electron beam simulation using variance reduction technique
NASA Astrophysics Data System (ADS)
Jayamani, J.; Termizi, N. A. S. Mohd; Kamarulzaman, F. N. Mohd; Aziz, M. Z. Abdul
2017-05-01
Monte Carlo (MC) simulation for electron beam radiotherapy consumes a long computation time. An algorithm called variance reduction technique (VRT) in MC was implemented to speed up this duration. This work focused on optimisation of VRT parameter which refers to electron range rejection and particle history. EGSnrc MC source code was used to simulate (BEAMnrc code) and validate (DOSXYZnrc code) the Siemens Primus linear accelerator model with the non-VRT parameter. The validated MC model simulation was repeated by applying VRT parameter (electron range rejection) that controlled by global electron cut-off energy 1,2 and 5 MeV using 20 × 107 particle history. 5 MeV range rejection generated the fastest MC simulation with 50% reduction in computation time compared to non-VRT simulation. Thus, 5 MeV electron range rejection utilized in particle history analysis ranged from 7.5 × 107 to 20 × 107. In this study, 5 MeV electron cut-off with 10 × 107 particle history, the simulation was four times faster than non-VRT calculation with 1% deviation. Proper understanding and use of VRT can significantly reduce MC electron beam calculation duration at the same time preserving its accuracy.
Chemical Consequences of Radioactive Decay and their Biological Implications.
DeJesus, Onofre T
2017-11-10
The chemical effects of radioactive decay arise from (1) transmutation, (2) formation of charged daughter nuclei, (3) recoil of the daughter nuclei, (4) electron "shakeoff" phenomenon and (5) vacancy cascade in decays via electron capture and internal conversion. This review aims to reiterate what has been known for a long time regarding the chemical consequences of radioactive decay and gives a historical perspective to the observations that led to their elucidation. The energetics of the recoil process in each decay mode is discussed in relation to the chemical bond between the decaying nucleus and the parent molecule. Special attention is given to the biological effects of the Auger process following decay by electron capture and internal conversion because of their possible utility in internal radiotherapy. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
In vivo dosimetry in external beam radiotherapy.
Mijnheer, Ben; Beddar, Sam; Izewska, Joanna; Reft, Chester
2013-07-01
In vivo dosimetry (IVD) is in use in external beam radiotherapy (EBRT) to detect major errors, to assess clinically relevant differences between planned and delivered dose, to record dose received by individual patients, and to fulfill legal requirements. After discussing briefly the main characteristics of the most commonly applied IVD systems, the clinical experience of IVD during EBRT will be summarized. Advancement of the traditional aspects of in vivo dosimetry as well as the development of currently available and newly emerging noninterventional technologies are required for large-scale implementation of IVD in EBRT. These new technologies include the development of electronic portal imaging devices for 2D and 3D patient dosimetry during advanced treatment techniques, such as IMRT and VMAT, and the use of IVD in proton and ion radiotherapy by measuring the decay of radiation-induced radionuclides. In the final analysis, we will show in this Vision 20∕20 paper that in addition to regulatory compliance and reimbursement issues, the rationale for in vivo measurements is to provide an accurate and independent verification of the overall treatment procedure. It will enable the identification of potential errors in dose calculation, data transfer, dose delivery, patient setup, and changes in patient anatomy. It is the authors' opinion that all treatments with curative intent should be verified through in vivo dose measurements in combination with pretreatment checks.
Tamaki, Tomoaki; Ohno, Tatsuya; Kiyohara, Hiroki; Noda, Shin-ei; Ohkubo, Yu; Ando, Ken; Wakatsuki, Masaru; Kato, Shingo; Kamada, Tadashi; Nakano, Takashi
2013-04-05
Recurrences of cervical cancer after definitive radiotherapy often occur at common iliac or para-aortic lymph nodes as marginal lymph node recurrences. Patients with these recurrences have a chance of long-term survival by optimal re-treatment with radiotherapy. However, the re-irradiation often overlaps the initial and the secondary radiotherapy fields and can result in increased normal tissue toxicities in the bowels or the stomach. Carbon-ion radiotherapy, a form of particle beam radiotherapy using accelerated carbon ions, offers more conformal and sharp dose distribution than X-ray radiotherapy. Therefore, this approach enables the delivery of high radiation doses to the target while sparing its surrounding normal tissues. Marginal lymph node recurrences in common iliac lymph nodes after radiotherapy were treated successfully by carbon-ion radiotherapy in two patients. These two patients were initially treated with a combination of external beam radiotherapy and intracavitary and interstitial brachytherapy. However, the diseases recurred in the lymph nodes near the border of the initial radiotherapy fields after 22 months and 23 months. Because re-irradiation with X-ray radiotherapy may deliver high doses to a section of the bowels, carbon-ion radiotherapy was selected to treat the lymph node recurrences. A total dose of 48 Gy (RBE) in 12 fractions over 3 weeks was given to the lymph node recurrences, and the tumors disappeared completely with no severe acute toxicities. The two patients showed no evidence of disease for 75 months and 63 months after the initial radiotherapy and for 50 months and 37 months after the carbon-ion radiotherapy, respectively. No severe late adverse effects are observed in these patients. The two presented cases suggest that the highly conformal dose distribution of carbon-ion radiotherapy may be beneficial in the treatment of marginal lymph node recurrences after radiotherapy. In addition, the higher biological effect of carbon-ion radiotherapy and its superior dose distribution may provide more effective tumor control in treatment for re-irradiation of the marginal recurrences in radiation resistant tumors other than cervical cancer.
2014-06-01
BEAMnrc Monte Carlo (MC) codes were used to simulate 50- 150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a...performed on water-only geometry and water with segmented prostheses ( steel and Ti) geometries with 100MeV and 150MeV beams...8 Results: 100MeV PDD 5cm behind steel /Ti heterogeneity was 51% less than in the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapoor, R; Palta, J; Hagan, M
Purpose: This Web-based Radiotherapy Incident Reporting and Analysis System (RIRAS) is a tool to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: VA’s National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and good-catch data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. This VA-Intranet based software design has made use of dataset taxonomies and data dictionaries defined in AAPM/ASTRO reports on error reporting. We used proven industrial and medicalmore » event reporting techniques to avoid several common problems faced in effective data collection such as incomplete data due to data entry fatigue by the reporters, missing data due to data difficult to obtain or not familiar to most reporters, missing reports due to fear of reprisal etc. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The analysis reports with corrective, learning actions are shared with the reporter/facility and made public to the community (after deidentification) as part of the learning process. Results: Till date 50 incident/good catches have been reported in RIRAS and we have completed analysis on 100% of these reports. This is done due to the fact that each reported incidents is investigated and a complete analysis/patient-safety-work-product report is generated by radiation oncology domain-experts. Conclusions Because of the completeness of the data, the system has enabled us to analyze process steps and track trends of major errors which in the future will lead to implementing system wide process improvement steps and safe standard operating procedures for each radiotherapy treatment modality/technique and fulfills our goal of “Effecting Quality While Treating Safely”. RIRAS developed and copyrighted by TSG Innovations Inc.« less
Balosso, Jacques
2017-01-01
Background During the past decades, in radiotherapy, the dose distributions were calculated using density correction methods with pencil beam as type ‘a’ algorithm. The objectives of this study are to assess and evaluate the impact of dose distribution shift on the predicted secondary cancer risk (SCR), using modern advanced dose calculation algorithms, point kernel, as type ‘b’, which consider change in lateral electrons transport. Methods Clinical examples of pediatric cranio-spinal irradiation patients were evaluated. For each case, two radiotherapy treatment plans with were generated using the same prescribed dose to the target resulting in different number of monitor units (MUs) per field. The dose distributions were calculated, respectively, using both algorithms types. A gamma index (γ) analysis was used to compare dose distribution in the lung. The organ equivalent dose (OED) has been calculated with three different models, the linear, the linear-exponential and the plateau dose response curves. The excess absolute risk ratio (EAR) was also evaluated as (EAR = OED type ‘b’ / OED type ‘a’). Results The γ analysis results indicated an acceptable dose distribution agreement of 95% with 3%/3 mm. Although, the γ-maps displayed dose displacement >1 mm around the healthy lungs. Compared to type ‘a’, the OED values from type ‘b’ dose distributions’ were about 8% to 16% higher, leading to an EAR ratio >1, ranged from 1.08 to 1.13 depending on SCR models. Conclusions The shift of dose calculation in radiotherapy, according to the algorithm, can significantly influence the SCR prediction and the plan optimization, since OEDs are calculated from DVH for a specific treatment. The agreement between dose distribution and SCR prediction depends on dose response models and epidemiological data. In addition, the γ passing rates of 3%/3 mm does not translate the difference, up to 15%, in the predictions of SCR resulting from alternative algorithms. Considering that modern algorithms are more accurate, showing more precisely the dose distributions, but that the prediction of absolute SCR is still very imprecise, only the EAR ratio could be used to rank radiotherapy plans. PMID:28811995
Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film
NASA Astrophysics Data System (ADS)
Gamble, Lisa M.; Farrell, Thomas J.; Jones, Glenn W.; Hayward, Joseph E.
2003-04-01
Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions.
Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film.
Gamble, Lisa M; Farrell, Thomas J; Jones, Glenn W; Hayward, Joseph E
2003-04-07
Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions.
Chang, Meng-Ya; Shiau, Ai-Li; Chen, Yu-Hung; Chang, Chih-Jui; Chen, Helen H-W; Wu, Chao-Liang
2008-07-01
High atomic number material, such as gold, may be used in conjunction with radiation to provide dose enhancement in tumors. In the current study, we investigated the dose-enhancing effect and apoptotic potential of gold nanoparticles in combination with single-dose clinical electron beams on B16F10 melanoma tumor-bearing mice. We revealed that the accumulation of gold nanoparticles was detected inside B16F10 culture cells after 18 h of incubation, and moreover, the gold nanoparticles were shown to be colocalized with endoplasmic reticulum and Golgi apparatus in cells. Furthermore, gold nanoparticles radiosensitized melanoma cells in the colony formation assay (P = 0.02). Using a B16F10 tumor-bearing mouse model, we further demonstrated that gold nanoparticles in conjunction with ionizing radiation significantly retarded tumor growth and prolonged survival compared to the radiation alone controls (P < 0.05). Importantly, an increase of apoptotic signals was detected inside tumors in the combined treatment group (P < 0.05). Knowing that radiation-induced apoptosis has been considered a determinant of tumor responses to radiation therapy, and the length of tumor regrowth delay correlated with the extent of apoptosis after single-dose radiotherapy, these results may suggest the clinical potential of gold nanoparticles in improving the outcome of melanoma radiotherapy.
PTW-diamond detector: dose rate and particle type dependence.
Fidanzio, A; Azario, L; Miceli, R; Russo, A; Piermattei, A
2000-11-01
In this paper the suitability of a PTW natural diamond detector (DD) for relative and reference dosimetry of photon and electron beams, with dose per pulse between 0.068 mGy and 0.472 mGy, was studied and the results were compared with those obtained by a stereotactic silicon detector (SFD). The results show that, in the range of the examined dose per pulse the DD sensitivity changes up to 1.8% while the SFD sensitivity changes up to 4.5%. The fitting parameter, delta, used to correct the dose per pulse dependence of solid state detectors, was delta = 0.993 +/- 0.002 and delta = 1.025 +/- 0.002 for the diamond detector and for the silicon diode, respectively. The delta values were found to be independent of particle type of two conventional beams (a 10 MV x-ray beam and a 21 MeV electron beam). So if delta is determined for a radiotherapy beam, it can be used to correct relative dosimetry for other conventional radiotherapy beams. Moreover the diamond detector shows a calibration factor which is independent of beam quality and particle type, so an empirical dosimetric formalism is proposed here to obtain the reference dosimetry. This formalism is based on a dose-to-water calibration factor and on an empirical coefficient, that takes into account the reading dependence on the dose per pulse.
Blake, S J; McNamara, A L; Vial, P; Holloway, L; Kuncic, Z
2014-11-21
A Monte Carlo model of a novel electronic portal imaging device (EPID) has been developed using Geant4 and its performance for imaging and dosimetry applications in radiotherapy has been characterised. The EPID geometry is based on a physical prototype under ongoing investigation and comprises an array of plastic scintillating fibres in place of the metal plate/phosphor screen in standard EPIDs. Geometrical and optical transport parameters were varied to investigate their impact on imaging and dosimetry performance. Detection efficiency was most sensitive to variations in fibre length, achieving a peak value of 36% at 50 mm using 400 keV x-rays for the lengths considered. Increases in efficiency for longer fibres were partially offset by reductions in sensitivity. Removing the extra-mural absorber surrounding individual fibres severely decreased the modulation transfer function (MTF), highlighting its importance in maximising spatial resolution. Field size response and relative dose profile simulations demonstrated a water-equivalent dose response and thus the prototype's suitability for dosimetry applications. Element-to-element mismatch between scintillating fibres and underlying photodiode pixels resulted in a reduced MTF for high spatial frequencies and quasi-periodic variations in dose profile response. This effect is eliminated when fibres are precisely matched to underlying pixels. Simulations strongly suggest that with further optimisation, this prototype EPID may be capable of simultaneous imaging and dosimetry in radiotherapy.
Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields
NASA Astrophysics Data System (ADS)
McNiven, Andrea L.
The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the computed tomography dose index (CTDI), a concept normally used in diagnostic radiology. This involved experimental determination of the fan beam thickness using the ion chambers to acquire fan beam profiles and extrapolation to a 'zero-size' detector. In conclusion, improvements have been made in the accuracy of small field dosimetry measurements in stereotactic radiotherapy and helical tomotherapy. This was completed through introduction of an original technique involving micro-CT imaging for sensitive volume determination and potentially ion chamber calibration coefficients, the use of appropriate Monte Carlo derived correction factors for RDF measurement, and the exploitation of the partial volume effect for helical tomotherapy fan beam dosimetry. With improved dosimetry for a wide range of challenging small x-ray field situations, it is expected that the patient's radiation safety will be maintained, and that clinical trials will adopt calibration protocols specialized for modern radiotherapy with small fields or beamlets. Keywords. radiation therapy, ionization chambers, small field dosimetry, stereotactic radiotherapy, helical tomotherapy, micro-CT.
Thilmann, C; Adamietz, I A; Ramm, U; Mose, S; Saran, F; Böttcher, H D
1996-05-01
Silicone-coated polyamide wound dressing is frequently used for the supportive treatment in patients with radiation induced skin lesions. The use of this kind of dressing during radiotherapy with high energy beams shifts the dose built-up effect towards the skin surface. Thus the dose delivered to the skin increases. The present work quantifies changes of the skin dose by a commercial silicon-coated polyamide wound dressing. The dependence on the beam quality and on different treatment techniques is investigated. Measurements were performed with photon (60Co, 6 MV, 42 MV) and electron (7 MeV, 20 MeV, 40 MeV) beams using thin LiF thermoluminescence dosimeters (TLD) in a perspex phantom. The beams were directed perpendicularly to the phantom surface. For 60Co and 6 MV photon beams the skin dose was evaluated in vivo at different beam arrangements and at a given reference dose. For 60Co, 6 MV and 42 MV photon beams wound dressing caused a dose increase on the surface of the perspex phantom by a factor of 1.65, 1.39 and 1.33 respectively. Using oblique or rotational techniques for 60Co and 6 MV photon irradiation the wound dressing increased the skin dose but less compared to perpendicular beam direction. For electron beams the skin dose is relatively high (from 84% to 92%) and an increase by a dressing has no clinical relevance (factor 1.03 to 1.05). The silicone-coated polyamide wound dressing causes no relevant skin dose increase during radiation treatment with electron beams and can be left on the skin during irradiation. During radiation treatment with photon beams like 60Co and 6 MV the protective procedure should be adapted to skin changes, in case of strong skin reactions a removal during the time of irradiation should be considered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harron, Elizabeth, E-mail: elizabeth.harron@nuh.nhs.uk; Lewis, Joanne
2012-07-01
The aim of this study was to compare the dose to organs at risk (OARs) from different craniospinal radiotherapy treatment approaches available at the Northern Centre for Cancer Care (NCCC), with a particular emphasis on sparing the bowel. Method: Treatment plans were produced for a pediatric medulloblastoma patient with inflammatory bowel disease using 3D conformal 6-MV photons (3DCP), combined 3D 6-MV photons and 18-MeV electrons (3DPE), and helical photon TomoTherapy (HT). The 3DPE plan was a modification of the standard 3DCP technique, using electrons to treat the spine inferior to the level of the diaphragm. The plans were compared inmore » terms of the dose-volume data to OARs and the nontumor integral dose. Results: The 3DPE plan was found to give the lowest dose to the bowel and the lowest nontumor integral dose of the 3 techniques. However, the coverage of the spine planning target volume (PTV) was least homogeneous using this technique, with only 74.6% of the PTV covered by 95% of the prescribed dose. HT was able to achieve the best coverage of the PTVs (99.0% of the whole-brain PTV and 93.1% of the spine PTV received 95% of the prescribed dose), but delivered a significantly higher integral dose. HT was able to spare the heart, thyroid, and eyes better than the linac-based techniques, but other OARs received a higher dose. Conclusions: Use of electrons was the best method for reducing the dose to the bowel and the integral dose, at the expense of compromised spine PTV coverage. For some patients, HT may be a viable method of improving dose homogeneity and reducing selected OAR doses.« less
Sim, Cpc; Soong, Y L; Pang, Epp; Lim, C; Walker, G D; Manton, D J; Reynolds, E C; Wee, Jts
2018-06-01
To evaluate changes in xerostomia status, salivary characteristics and gland volumes 2 years following radiotherapy in nasopharyngeal carcinoma patients. Xerostomia scores, salivary flow rates, pH and buffering capacity were measured at pre-radiotherapy, mid-radiotherapy, 2 weeks, 3 months and 2 years post-radiotherapy. Salivary gland volumes and their correlation with radiation dose were also assessed. Mean radiation dose to oral cavity, parotid and submandibular glands (SMG) was 44.5, 65.0 and 38.6 Gy respectively. Parotid and SMG volumes decreased 33% at 3 months post-radiotherapy; volumes at 2 years post-radiotherapy were 84% and 51% of pre-radiotherapy levels, respectively. Correlations were observed between parotid gland volume per cent reduction and its radiation dose and between resting salivary flow rate reduction and post-radiotherapy/pre-radiotherapy SMG volume ratio. Salivary flow rates and resting saliva pH remained significantly low at 2 years post-radiotherapy (both flow rates, P = 0.001; resting saliva pH, P = 0.005). Similarly, xerostomia scores remained significantly higher compared with pre-radiotherapy levels. Submandibular gland volumetric shrinkage persisted 2 years after radiotherapy. Xerostomia scores remained significantly higher, and salivary flow rates and resting saliva pH remained significantly lower, suggesting that study participants were still at risk for hyposalivation-related oral diseases. © 2018 Australian Dental Association.
Superficial Dosimetry Imaging of Čerenkov Emission in Electron Beam Radiotherapy of Phantoms
Zhang, Rongxiao; Fox, Colleen J.; Glaser, Adam K.; Gladstone, David J.; Pogue, Brian W.
2014-01-01
Čerenkov emission is generated from ionizing radiation in tissue above 264keV energy. This study presents the first examination of this optical emission as a surrogate for the absorbed superficial dose. Čerenkov emission was imaged from the surface of flat tissue phantoms irradiated with electrons, using a range of field sizes from 6cm×6cm to 20cm×20cm, incident angles from 0 to 50 degrees, and energies from 6 to 18 MeV. The Čerenkov images were compared with estimated superficial dose in phantoms from direct diode measurements, as well as calculations by Monte Carlo and the treatment planning system. Intensity images showed outstanding linear agreement (R2=0.97) with reference data of the known dose for energies from 6MeV to 18MeV. When orthogonal delivery was done, the in-plane and cross-plane dose distribution comparisons indicated very little difference (±2~4% differences) between the different methods of estimation as compared to Čerenkov light imaging. For an incident angle 50 degrees, the Čerenkov images and Monte Carlo simulation show excellent agreement with the diode data, but the treatment planning system (TPS) had at a larger error (OPT=±1~2%, Diode=±2~3%, TPS=±6~8% differences) as would be expected. The sampling depth of superficial dosimetry based on Čerenkov radiation has been simulated in layered skin model, showing the potential of sampling depth tuning by spectral filtering. Taken together, these measurements and simulations indicate that Čerenkov emission imaging might provide a valuable way to superficial dosimetry imaging from incident radiotherapy beams of electrons. PMID:23880473
Kubo, Nobuteru; Saitoh, Jun-Ichi; Shimada, Hirofumi; Shirai, Katsuyuki; Kawamura, Hidemasa; Ohno, Tatsuya; Nakano, Takashi
2016-09-01
The present study compared the dose-volume histograms of patients with Stage IIIA non-small cell lung cancer (NSCLC) treated with carbon ion radiotherapy with those of patients treated with X-ray radiotherapy. Patients with Stage IIIA NSCLC (n = 10 patients for each approach) were enrolled. Both radiotherapy plans were calculated with the same targets and organs at risk on the same CT. The treatment plan for the prophylactic lymph node and primary tumor (PTV1) delivered 40 Gy for X-ray radiotherapy and 40 Gy (relative biological effectiveness; RBE) for carbon ion radiotherapy. The total doses for the primary tumor and clinically positive lymph nodes (PTV2) were 60 Gy for X-ray radiotherapy and 60 Gy (RBE) for carbon ion radiotherapy. The homogeneity indexes for PTV1 and PTV2 were superior for carbon ion radiotherapy in comparison with X-ray radiotherapy (PTV1, 0.57 vs 0.65, P = 0.009; PTV2, 0.07 vs 0.16, P = 0.005). The normal lung mean dose, V5, V10 and V20 for carbon ion radiotherapy were 7.7 Gy (RBE), 21.4%, 19.7% and 17.0%, respectively, whereas the corresponding doses for X-ray radiotherapy were 11.9 Gy, 34.9%, 26.6% and 20.8%, respectively. Maximum spinal cord dose, esophageal maximum dose and V50, and bone V10, V30 and V50 were lower with carbon ion radiotherapy than with X-ray radiotherapy. The present study indicates that carbon ion radiotherapy provides a more homogeneous target dose and a lower dose to organs at risk than X-ray radiotherapy for Stage IIIA non-small cell lung cancer. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
SU-E-J-200: Operation of An Electron Accelerator On An Integrated MR-Linac System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harasimowicz, J; Roberts, D; Shinton, I
2015-06-15
Purpose: An integrated MRI guided radiotherapy system poses a challenge of operating a linear accelerator in the presence of a magnetic field as the magnetic force acting on the electrons could Result in radiation source displacement and subsequent reduction of dose output. It was the purpose of this work to test the performance of a linac in the presence of a 1.5T MRI system. Methods: The first experimental MRI guided radiotherapy system at UMC-Utrecht consisting of an Elekta linac rotating around a 1.5T Magnex magnet was examined. A passive magnetic shield was simulated, designed and installed to reduce the influencemore » of the MRI magnet stray field on the electron beamline. The B field inside the shield was measured as a function of gantry angle and measurements of dose rate constancy upon gantry rotation were performed. Results: The magnitude of the magnetic field on the electron beam path without the shield was as high as 70G. It varied by up to 15G with gantry rotation due to the presence of metal beams in the bunker floor which resulted in dose output drop of up to 70% at certain gantry angles. With the prototype shield, field magnitude was reduced to well below 0.5G everywhere along the electron beam path. Field variation with gantry rotation was decreased to below 0.2G and enabled dose output of the linac to be recovered at all gantry angles. The homogeneity of the field inside the MRI magnet has not been compromised. Conclusion: It was demonstrated that the influence of the 1.5T magnet and the bunker design on the linac operation has been minimised. The performance will be further improved on the Elekta Atlantic system which incorporates a newly developed and optimised Philips magnet design and bunker construction. J Harasimowicz, D Roberts, I Shinton and S Sund are employed by Elekta Limited Crawley, H Wang and M Zhong are employed by Elekta Beijing Medical Systems Co. Ltd., J Overweg is employed by Philips Technologie GmbH Forschungslaboratorien.« less
Stereotactic body radiotherapy for lung cancer: how much does it really cost?
Lievens, Yolande; Obyn, Caroline; Mertens, Anne-Sophie; Van Halewyck, Dries; Hulstaert, Frank
2015-03-01
Despite the lack of randomized evidence, stereotactic body radiotherapy (SBRT) is being accepted as superior to conventional radiotherapy for patients with T1-2N0 non-small-cell lung cancer in the periphery of the lung and unfit or unwilling to undergo surgery. To introduce SBRT in a system of coverage with evidence development, a correct financing had to be determined. A time-driven activity-based costing model for radiotherapy was developed. Resource cost calculation of all radiotherapy treatments, standard and innovative, was conducted in 10 Belgian radiotherapy centers in the second half of 2012. The average cost of lung SBRT across the 10 centers (6221&OV0556;) is in the range of the average costs of standard fractionated 3D-conformal radiotherapy (5919&OV0556;) and intensity-modulated radiotherapy (7379&OV0556;) for lung cancer. Hypofractionated 3D-conformal radiotherapy and intensity-modulated radiotherapy schemes are less costly (3993&OV0556; respectively 4730&OV0556;). The SBRT cost increases with the number of fractions and is highly dependent of personnel and equipment use. SBRT cost varies more by centre than conventional radiotherapy cost, reflecting different technologies, stages in the learning curve and a lack of clear guidance in this field. Time-driven activity-based costing of radiotherapy is feasible in a multicentre setup, resulting in real-life resource costs that can form the basis for correct reimbursement schemes, supporting an early yet controlled introduction of innovative radiotherapy techniques in clinical practice.
Olbrant, Edgar; Frank, Martin
2010-12-01
In this paper, we study a deterministic method for particle transport in biological tissues. The method is specifically developed for dose calculations in cancer therapy and for radiological imaging. Generalized Fokker-Planck (GFP) theory [Leakeas and Larsen, Nucl. Sci. Eng. 137 (2001), pp. 236-250] has been developed to improve the Fokker-Planck (FP) equation in cases where scattering is forward-peaked and where there is a sufficient amount of large-angle scattering. We compare grid-based numerical solutions to FP and GFP in realistic medical applications. First, electron dose calculations in heterogeneous parts of the human body are performed. Therefore, accurate electron scattering cross sections are included and their incorporation into our model is extensively described. Second, we solve GFP approximations of the radiative transport equation to investigate reflectance and transmittance of light in biological tissues. All results are compared with either Monte Carlo or discrete-ordinates transport solutions.
NASA Astrophysics Data System (ADS)
Bailey, M.; Shipley, D. R.; Manning, J. W.
2015-02-01
Empirical fits are developed for depth-compensated wall- and cavity-replacement perturbations in the PTW Roos 34001 and IBA / Scanditronix NACP-02 parallel-plate ionisation chambers, for electron beam qualities from 4 to 22 MeV for depths up to approximately 1.1 × R50,D. These are based on calculations using the Monte Carlo radiation transport code EGSnrc and its user codes with a full simulation of the linac treatment head modelled using BEAMnrc. These fits are used with calculated restricted stopping-power ratios between air and water to match measured depth-dose distributions in water from an Elekta Synergy clinical linear accelerator at the UK National Physical Laboratory. Results compare well with those from recent publications and from the IPEM 2003 electron beam radiotherapy Code of Practice.
Bahreyni Toossi, Mohammad Taghi; Momennezhad, Mehdi; Hashemi, Seyed Mohammad
2012-01-01
Aim Exact knowledge of dosimetric parameters is an essential pre-requisite of an effective treatment in radiotherapy. In order to fulfill this consideration, different techniques have been used, one of which is Monte Carlo simulation. Materials and methods This study used the MCNP-4Cb to simulate electron beams from Neptun 10 PC medical linear accelerator. Output factors for 6, 8 and 10 MeV electrons applied to eleven different conventional fields were both measured and calculated. Results The measurements were carried out by a Wellhofler-Scanditronix dose scanning system. Our findings revealed that output factors acquired by MCNP-4C simulation and the corresponding values obtained by direct measurements are in a very good agreement. Conclusion In general, very good consistency of simulated and measured results is a good proof that the goal of this work has been accomplished. PMID:24377010
Ji, Fanceng; Nie, Peihe; Yi, Fuxia; Zhang, Limin
2015-01-01
Although the placement of esophageal self-expandable stents (SES) can effectively relieve dysphagia after radiotherapy in patients with esophageal cancer (EC), it may induce severe esophageal complications. This article reports a case of emergency endotracheal intubation in an EC patient who suddenly developed severe dyspnea two months after SES placement. Electronic bronchoscopy of the patient's airway confirmed the diagnosis of esophagotracheal fistula, tracheal stenosis and tracheal rupture. Endotracheal intubation was successfully performed under the guidance of electronic bronchoscopy. Dyspnea due to tracheal stenosis was relieved effectively by inserting the tracheal catheter to a proper place under the guidance of electronic bronchoscopy. Bronchoscopic examination is strongly recommended in EC patients who are highly suspected as having airway stenosis associated with esophageal stenting, for which endotracheal intubation under the guidance of bronchoscopy is suggested.
Bertorelle, Franck; Russier-Antoine, Isabelle; Calin, Nathalie; Comby-Zerbino, Clothilde; Bensalah-Ledoux, Amina; Guy, Stephan; Dugourd, Philippe; Brevet, Pierre-François; Sanader, Željka; Krstić, Marjan; Bonačić-Koutecký, Vlasta; Antoine, Rodolphe
2017-05-04
We report facile synthesis of the Au 10 (SG) 10 nanoclusters, where SG stands for glutathione, found to be promising as a new class of radiosensitizers for cancer radiotherapy. The homoleptic catenane structure with two Au 5 SG 5 interconnected rings, among different isomer structures, gives the best agreement between theoretical and experimental optical spectra and XRD patterns. This catenane structure exhibits a centrosymmetry-broken structure, resulting in enhanced second harmonic response and new characteristic circular dichroism signals in the spectral region of 250-400 nm. This is the first determination of the nonlinear optical properties of a ligated cluster with an equal Au-to-ligand ratio, thus without a metallic core and therefore zero confined electrons. Insight into the nonlinear and chiroptical efficiencies arising from interplay between structural and electronic properties is provided by the TD-DFT approach.
Comparisons between MCNP, EGS4 and experiment for clinical electron beams.
Jeraj, R; Keall, P J; Ostwald, P M
1999-03-01
Understanding the limitations of Monte Carlo codes is essential in order to avoid systematic errors in simulations, and to suggest further improvement of the codes. MCNP and EGS4, Monte Carlo codes commonly used in medical physics, were compared and evaluated against electron depth dose data and experimental backscatter results obtained using clinical radiotherapy beams. Different physical models and algorithms used in the codes give significantly different depth dose curves and electron backscattering factors. The default version of MCNP calculates electron depth dose curves which are too penetrating. The MCNP results agree better with experiment if the ITS-style energy-indexing algorithm is used. EGS4 underpredicts electron backscattering for high-Z materials. The results slightly improve if optimal PRESTA-I parameters are used. MCNP simulates backscattering well even for high-Z materials. To conclude the comparison, a timing study was performed. EGS4 is generally faster than MCNP and use of a large number of scoring voxels dramatically slows down the MCNP calculation. However, use of a large number of geometry voxels in MCNP only slightly affects the speed of the calculation.
NASA Astrophysics Data System (ADS)
Yazdani, Mohammad Reza; Setayeshi, Saeed; Arabalibeik, Hossein; Akbari, Mohammad Esmaeil
2017-05-01
Intraoperative electron radiation therapy (IOERT), which uses electron beams for irradiating the target directly during the surgery, has the advantage of delivering a homogeneous dose to a controlled layer of tissue. Since the dose falls off quickly below the target thickness, the underlying normal tissues are spared. In selecting the appropriate electron energy, the accuracy of the target tissue thickness measurement is critical. In contrast to other procedures applied in IOERT, the routine measurement method is considered to be completely traditional and approximate. In this work, a novel mechanism is proposed for measuring the target tissue thickness with an acceptable level of accuracy. An electronic system has been designed and manufactured with the capability of measuring the tissue thickness based on the recorded electron density under the target. The results indicated the possibility of thickness measurement with a maximum error of 2 mm for 91.35% of data. Aside from system limitation in estimating the thickness of 5 mm phantom, for 88.94% of data, maximum error is 1 mm.
2015-09-01
used to simulate 50- 150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of...and water with segmented prostheses ( steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel /Ti heterogeneity...in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the
Radiosensitization of Hypoxic Tumor Cells by Depletion of Intracellular Glutathione
NASA Astrophysics Data System (ADS)
Bump, Edward A.; Yu, Ning Y.; Brown, J. Martin
1982-08-01
Depletion of glutathione in Chinese hamster ovary cells in vitro by diethyl maleate resulted in enhancement of the effect of x-rays on cell survival under hypoxic conditions but not under oxygenated conditions. Hypoxic EMT6 tumor cells were similarly sensitized in vivo. The action of diethyl maleate is synergistic with the effect of the electron-affinic radiosensitizer misonidazole, suggesting that the effectiveness of misonidazole in cancer radiotherapy may be improved by combining it with drugs that deplete intracellular glutathione.
2002-08-01
treatment of mice with 92.5 MBq (2.5 mCi) of ..In-DTPA-hEGF in five divided weekly doses. * Cumulative Radioactivity in Source Compartment (,s, Bq x...equiv- nalization of the radiopharmaceutical resulted in selective alent to a human dose of 14,208 MBq /m 2) can be safely and enhanced cytotoxicity in... be construed as an official Department of the Army position, policy or decision unless so designated by other documentation. " ROIForm Approved
Radiosensitization of hypoxic tumor cells by depletion of intracellular glutathione
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bump, E.A.; Yu, N.Y.; Brown, J.M.
1982-08-06
Depletion of glutathione in Chinese hamster ovary cells in vitro by diethyl maleate resulted in enhancement of the effect of x-rays on cell survival under hypoxic conditions but not under oxygenated conditions. Hypoxic EMT6 tumor cells were similarly sensitized in vivo. The action of diethyl maleate is synergistic with the effect of the electron-affinic radiosensitizer misonidazole, suggesting that the effectiveness of misonidazole in cancer radiotherapy may be improved by combining it with drugs that deplete intracellular glutathione.
El Shafie, Rami A; Bougatf, Nina; Sprave, Tanja; Weber, Dorothea; Oetzel, Dieter; Machmer, Timo; Huber, Peter E; Debus, Jürgen; Nicolay, Nils H
2018-03-06
The increasing role of consumer electronics and Web-enabled mobile devices in the medical sector opens up promising possibilities for integrating novel technical solutions into therapy and patient support for oncologic illnesses. A recent survey carried out at Heidelberg University Hospital suggested a high acceptance among patients for an additional approach to patient care during radiotherapy based on patient-reported outcomes by a dedicated mobile app. The aim of this trial (OPTIMISE-1: Oncologic Therapy Support Via Means of a Dedicated Mobile App - A Prospective Feasibility Evaluation) is to prospectively evaluate the feasibility of employing a mobile app for the systematic support of radiooncological patients throughout the course of their radiotherapy by monitoring symptoms and patient performance, and facilitating the background-exchange of relevant information between patient and physician. The present single-center, prospective, exploratory trial, conducted at Heidelberg University Hospital, assesses the feasibility of integrating an app-based approach into patient-care during radiotherapy. Patients undergoing curative radiotherapy for thoracic or pelvic tumors will be surveyed regarding general performance, treatment-related quality of life (QoL) and symptoms, and their need to personally consult a physician by means of a mobile app during treatment. The primary endpoint of feasibility will be reached when 80% of the patients have successfully answered 80% of their respective questions scheduled for each treatment day. Furthermore, treatment-related patient satisfaction and health-related QoL is assessed by the Patient Satisfaction Questionnaire Short Form (PSQ-18) and the European Organization for Research and Treatment of Cancer (EORTC) questionnaires at the beginning (baseline) and end of radiotherapy, and at the first follow-up. This trial will recruit 50 patients over a period of 12 months. Follow-up will be completed after 18 months, and publication of results is planned at 24 months after trial initiation. This study will serve as a basis for future studies aiming to exploit the constant innovation in mobile medical appliances and integrate novel patient-centered concepts into patient care in the context of radiotherapy. ClinicalTrials.gov NCT03168048; https://clinicaltrials.gov/ct2/show/NCT03168048 (Archived at WebCite http://www.webcitation.org/6wtWGgi0X). ©Rami A El Shafie, Nina Bougatf, Tanja Sprave, Dorothea Weber, Dieter Oetzel, Timo Machmer, Peter E Huber, Jürgen Debus, Nils H Nicolay. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 06.03.2018.
Lam, J; Cook, T; Foster, S; Poon, R; Milross, C; Sundaresan, P
2015-08-01
Radiotherapy utilisation is likely affected by multiple factors pertaining to radiotherapy access. Radiotherapy is an integral component of breast-conserving treatment (BCT) for early breast cancer. We aimed to determine if stepwise improvements in radiotherapy access in regional Australia affected the uptake of BCT and thus radiotherapy. Breast cancer operations in the Central Coast of New South Wales between January 2010 and March 2014 for T1-2N0-1M0 invasive or in situ (≤5 cm) disease in female patients eligible for BCT were examined. BCT uptake was calculated for three 1 year periods: period 1 (local radiotherapy available at cost to user or out of area radiotherapy with travel cost and inconvenience); period 2 (as per period 1 + publicly funded transport and radiotherapy at out of area facilities at no cost to user); period 3 (as per period 1 + publicly funded local radiotherapy at no cost to user). In total, 574 cases met eligibility criteria. BCT declined with increasing distance to publicly funded radiotherapy (P = 0.035). BCT rates for periods 1, 2 and 3 were 63% (113/180), 61% (105/173) and 71% (156/221). There were no statistically significant differences in BCT between periods 1 and 2 in the whole cohort or within age, histology or tumour size subgroups. Overall, there was a 9% increase in BCT in the whole cohort in period 3 compared with periods 1 and 2 (P = 0.031). This increase was statistically significant for women over 70 years (19% increase, P = 0.034), for women with ductal carcinoma in situ (25% increase, P = 0.013) and for women with primary tumours that were ≤10 mm (21% increase, P = 0.016). Improving the affordability of radiotherapy through publicly funded transport and radiotherapy at out of area facilities did not improve BCT uptake in a region where radiotherapy was locally available, albeit at cost to the user. Improving both affordability and convenience through the provision of local publicly funded radiotherapy increased BCT uptake. Service availability and affordability have long been recognised as important determinants of radiotherapy access. Our findings suggest that inconvenience may also influence radiotherapy utilisation. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Very Early Salvage Radiotherapy Improves Distant Metastasis-Free Survival.
Abugharib, Ahmed; Jackson, William C; Tumati, Vasu; Dess, Robert T; Lee, Jae Y; Zhao, Shuang G; Soliman, Moaaz; Zumsteg, Zachary S; Mehra, Rohit; Feng, Felix Y; Morgan, Todd M; Desai, Neil; Spratt, Daniel E
2017-03-01
Early salvage radiotherapy following radical prostatectomy for prostate cancer is commonly advocated in place of adjuvant radiotherapy. We aimed to determine the optimal definition of early salvage radiotherapy. We performed a multi-institutional retrospective study of 657 men who underwent salvage radiotherapy between 1986 and 2013. Two comparisons were made to determine the optimal definition of early salvage radiotherapy, including 1) the time from radical prostatectomy to salvage radiotherapy (less than 9, 9 to 21, 22 to 47 or greater than 48 months) and 2) the level of detectable pre-salvage radiotherapy prostate specific antigen (0.01 to 0.2, greater than 0.2 to 0.5 or greater than 0.5 ng/ml). Outcomes included freedom from salvage androgen deprivation therapy, and biochemical relapse-free, distant metastases-free and prostate cancer specific survival. Median followup was 9.8 years. Time from radical prostatectomy to salvage radiotherapy did not correlate with 10-year biochemical relapse-free survival rates (R 2 = 0.18). Increasing pre-salvage radiotherapy prostate specific antigen strongly correlated with biochemical relapse-free survival (R 2 = 0.91). Increasing detectable pre-salvage radiotherapy prostate specific antigen (0.01 to 0.2, greater than 0.2 to 0.5 and greater than 0.5 ng/ml) predicted worse 10-year biochemical relapse-free survival (62%, 44% and 27%), freedom from salvage androgen deprivation therapy (77%, 66% and 49%), distant metastases-free survival (86%, 79% and 66%, each p <0.001) and prostate cancer specific survival (93%, 89% and 80%, respectively, p = 0.001). On multivariable analysis early salvage radiotherapy (prostate specific antigen greater than 0.2 to 0.5 ng/ml) was associated with a twofold increase in biochemical failure, use of salvage androgen deprivation therapy and distant metastases compared to very early salvage radiotherapy (prostate specific antigen 0.01 to 0.2 ng/ml). The duration from radical prostatectomy to salvage radiotherapy is not independently prognostic for outcomes after salvage radiotherapy and it should not be used to define early salvage radiotherapy. Grouping all patients with pre-salvage radiotherapy prostate specific antigen 0.5 ng/ml or less may be inadequate to define early salvage radiotherapy and it has a relevant impact on ongoing and future clinical trials. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schembri, V.; Heijmen, B. J. M.
2007-06-15
Introduction and Purpose: Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al{sub 2}O{sub 3}:C) for dosimetry in therapeutic photon and electron beams. Materials and Methods: The OSL films consist of a polystyrene sheet, with a top layer of a mixture of single crystals of Al{sub 2}O{sub 3}:C, ground into a powder, and a polyester base. The total thickness of the films is 0.3 mm. Measurements have been performed in a water equivalent phantom, using 4, 6,more » 10, and 18 MV photon beams, and 6-22 MeV electron beams. The studies include assessment of the film response (acquired OSL signal/delivered dose) on delivered dose (linearity), dose rate (1-6 Gy/min), beam quality, field size and depth (6 MV, ranges 4x4-30x30 cm{sup 2}, d{sub max}-35 cm). Doses have been derived from ionization chamber measurements. OSL films have also been compared with conventional x-ray and GafChromic films for dosimetry outside the high dose area, with a high proportion of low dose scattered photons. In total, 787 OSL films have been irradiated. Results: Overall, the OSL response for electron beams was 3.6% lower than for photon beams. Differences between the various electron beam energies were not significant. The 6 and 18 MV photon beams differed in response by 4%. No response dependencies on dose rate were observed. For the 6 MV beam, the field size and depth dependencies of the OSL response were within {+-}2.5%. The observed inter-film response variation for films irradiated with the same dose varied from 1% to 3.2% (1 SD), depending on the measurement day. At a depth of 20 cm, 5 cm outside the 20x20 cm{sup 2} 6 and 18 MV beams, an over response of 17% was observed. In contrast to GafChromic and conventional x-ray films, the response of the Al{sub 2}O{sub 3}:C films is linear in the clinically relevant dose range 0-200 cGy. Conclusions: Measurement of the OSL signal of irradiated films containing Al{sub 2}O{sub 3}:C is a promising technique for film dosimetry in radiotherapy with no or small response variations with dose rate, beam quality, field size and depth, and a linear response from 0 to 200 cGy.« less
Adams, William M; Bjorling, Dale E; McAnulty, Jonathan E; Green, Eric M; Forrest, Lisa J; Vail, David M
2005-09-15
To compare long-term results of radiotherapy alone versus radiotherapy followed by exenteration of the nasal cavity in dogs with malignant intranasal neoplasia. Retrospective study. 53 dogs with malignant intranasal neoplasia. All dogs underwent radiotherapy consisting of administration of 10 fractions of 4.2 Gy each on consecutive weekdays. For dogs in the surgery group (n=13), follow-up computed tomography was performed, and dogs were scheduled for surgery if persistent or recurrent tumor was seen. Perioperative complications for dogs that underwent surgery included hemorrhage requiring transfusion (2 dogs) and subcutaneous emphysema (8). Rhinitis and osteomyelitis-osteonecrosis occurred significantly more frequently in dogs in the radiotherapy and surgery group (9 and 4 dogs, respectively) than in dogs in the radiotherapy-only group (4 and 3 dogs, respectively). Two- and 3-year survival rates were 44% and 24%, respectively, for dogs in the radiotherapy group and 69% and 58%, respectively, for dogs in the surgery group. Overall median survival time for dogs in the radiotherapy and surgery group (477 months) was significantly longer than time for dogs in the radiotherapy-only group (19.7 months). Results suggest that exenteration of the nasal cavity significantly prolongs survival time in dogs with intranasal neoplasia that have undergone radiotherapy. Exenteration after radiotherapy may increase the risk of chronic complications.
Kann, Benjamin H; Park, Henry S; Lester-Coll, Nataniel H; Yeboa, Debra N; Benitez, Viviana; Khan, Atif J; Bindra, Ranjit S; Marks, Asher M; Roberts, Kenneth B
2016-12-01
Postoperative radiotherapy to the craniospinal axis is standard-of-care for pediatric medulloblastoma but is associated with long-term morbidity, particularly in young children. With the advent of modern adjuvant chemotherapy strategies, postoperative radiotherapy deferral has gained acceptance in children younger than 3 years, although it remains controversial in older children. To analyze recent postoperative radiotherapy national treatment patterns and implications for overall survival in patients with medulloblastoma ages 3 to 8 years. Using the National Cancer Data Base, patients ages 3 to 8 years diagnosed as having histologically confirmed medulloblastoma in 2004 to 2012, without distant metastases, who underwent surgery and adjuvant chemotherapy with or without postoperative radiotherapy at facilities nationwide accredited by the Commission on Cancer were identified. Patients were designated as having "postoperative radiotherapy upfront" if they received radiotherapy within 90 days of surgery or "postoperative radiotherapy deferred" otherwise. Factors associated with postoperative radiotherapy deferral were identified using multivariable logistic regression. Overall survival (OS) was compared using Kaplan-Meier analysis with log-rank tests and multivariable Cox regression. Statistical tests were 2-sided. Postoperative radiotherapy utilization and overall survival. Among 816 patients, 123 (15.1%) had postoperative radiotherapy deferred, and 693 (84.9%) had postoperative radiotherapy upfront; 36.8% of 3-year-olds and 4.1% of 8-year-olds had postoperative radiotherapy deferred (P < .001). On multivariable logistic regression, variables associated with postoperative radiotherapy deferral were age (odds ratio [OR], 0.57 per year; 95% CI, 0.49-0.67 per year) and year of diagnosis (OR, 1.18 per year; 95% CI, 1.08-1.29 per year). On survival analysis, with median follow-up of 4.8 years, OS was improved for those receiving postoperative radiotherapy upfront vs postoperative radiotherapy deferred (5-year OS: 82.0% vs 63.4%; P < .001). On multivariable analysis, variables associated with poorer OS were postoperative radiotherapy deferral (hazards ratio [HR], 1.95; 95% CI, 1.15-3.31); stage M1-3 disease (HR, 1.86; 95% CI, 1.10-3.16), and low facility volume (HR, 1.75; 95% CI, 1.04-2.94). Our national database analysis reveals a higher-than-expected and increasing rate of postoperative radiotherapy deferral in children with medulloblastoma ages 3 to 8 years. The analysis suggests that postoperative radiotherapy deferral is associated with worse survival in this age group, even in the modern era of chemotherapy.
Nakamura, Katsumasa; Konishi, Kenta; Komatsu, Tetsuya; Sasaki, Tomonari; Shikama, Naoto
2018-05-01
In high-income countries, the number of radiotherapy machine per population reaches a sufficient level. However, the patterns of infrastructure of radiotherapy in high-income countries are not well known. Among 29 high-income countries with gross national income of $25,000 or more per capita, we selected 23 countries whose total number of newly diagnosed cancer patients in 2012 was reported in the Organisation for Economic Co-operation and Development Health Statistics 2017. The numbers of radiotherapy centers and teletherapy machines in each of these 23 countries were collected using the Dictionary of Radiotherapy Centers database. The number of cancer patients per teletherapy machine was 452.35-1398.22 (median 711.66) with a three-fold variation, whereas the number of cancer patients per radiotherapy center varied even more widely, from 826.16 to 5159.86 (median 2259.83) with a six-fold variation. The average number of teletherapy machines per radiotherapy center also ranged widely, from 1.24 to 8.29 (median 3.11) with a seven-fold variation. The number of teletherapy machines in each country was almost proportional to that of cancer patients, and the number of teletherapy machines per radiotherapy center was inversely related to the number of radiotherapy centers per cancer patients. The number of teletherapy machines per radiotherapy center in Japan was 1.24, the most fragmented among the high-income countries. The percentage of large radiotherapy centers having three or more teletherapy machines in Japan was the smallest among 23 high-income countries. Optimization of the radiotherapy infrastructure in Japan should be carefully considered.
Chen, Wen-jun; Zhang, Xi; Wu, Cong-cong; Zhang, Chao-ying; Sun, Shuang-shuang; Wu, Jian
2017-01-01
Background There are no consistent agreements on whether radiotherapy after breast-conserving surgery (BCS) could provide local control and survival benefit for older patients with early breast cancer or breast ductal carcinoma in situ (DCIS). The present study aimed to evaluate the efficacy of radiotherapy after BCS in older patients with early breast cancer or DCIS. Results Radiotherapy could reduce the risk of local relapse in older patients with early breast cancer. The 5-year AR of local relapse was 2.2% and 6.2% for radiotherapy and non-radiotherapy group, respectively, with low 5-year ARD of 4.0% and high NNT of 25. The 10-year AR of local relapse was 5.3% and 10.5% for radiotherapy and non-radiotherapy group, respectively, with the 10-year ARD of 5.2% and NNT of 20. However, radiotherapy could not improve survival benefits, including overall survival, cancer-specific survival, breast-cancer-specific survival, and distant relapse. Moreover, radiotherapy could reduce the risk of ipsilateral breast events in older patients with DCIS. Materials and Methods PubMed and Embase database were searched for relevant studies. Hazard ratios (HRs), risk ratios (RRs), absolute risk (AR), absolute risk difference (ARD), and number needed to treat (NNT) were used as effect measures to evaluate the efficacy of radiotherapy in older patients. Conclusions Our study indicates that radiotherapy could slightly reduce the risk of local relapse in older patients with favorable early breast cancer. However, radiotherapy cannot translate into significant survival benefits. PMID:28415667
Barriers to radiotherapy access at the University College Hospital in Ibadan, Nigeria.
Anakwenze, Chidinma P; Ntekim, Atara; Trock, Bruce; Uwadiae, Iyobosa B; Page, Brandi R
2017-08-01
Nigeria has the biggest gap between radiotherapy availability and need, with one machine per 19.4 million people, compared to one machine per 250,000 people in high-income countries. This study aims to identify its patient-level barriers to radiotherapy access. This was a cross sectional study consisting of patient questionnaires ( n = 50) conducted in January 2016 to assess patient demographics, types of cancers seen, barriers to receiving radiotherapy, health beliefs and practices, and factors leading to treatment delay. Eighty percent of patients could not afford radiotherapy without financial assistance and only 6% of the patients had federal insurance, which did not cover radiotherapy services. Of the patients who had completed radiotherapy treatment, 91.3% had experienced treatment delay or often cancellation due to healthcare worker strike, power failure, machine breakdown, or prolonged wait time. The timeliness of a patient's radiotherapy care correlated with their employment status and distance from radiotherapy center ( p < 0.05). Barriers to care at a radiotherapy center in a low- and middle-income country (LMIC) have previously not been well characterized. These findings can be used to inform efforts to expand the availability of radiotherapy and improve current treatment capacity in Nigeria and in other LMICs.
A GPU OpenCL based cross-platform Monte Carlo dose calculation engine (goMC)
NASA Astrophysics Data System (ADS)
Tian, Zhen; Shi, Feng; Folkerts, Michael; Qin, Nan; Jiang, Steve B.; Jia, Xun
2015-09-01
Monte Carlo (MC) simulation has been recognized as the most accurate dose calculation method for radiotherapy. However, the extremely long computation time impedes its clinical application. Recently, a lot of effort has been made to realize fast MC dose calculation on graphic processing units (GPUs). However, most of the GPU-based MC dose engines have been developed under NVidia’s CUDA environment. This limits the code portability to other platforms, hindering the introduction of GPU-based MC simulations to clinical practice. The objective of this paper is to develop a GPU OpenCL based cross-platform MC dose engine named goMC with coupled photon-electron simulation for external photon and electron radiotherapy in the MeV energy range. Compared to our previously developed GPU-based MC code named gDPM (Jia et al 2012 Phys. Med. Biol. 57 7783-97), goMC has two major differences. First, it was developed under the OpenCL environment for high code portability and hence could be run not only on different GPU cards but also on CPU platforms. Second, we adopted the electron transport model used in EGSnrc MC package and PENELOPE’s random hinge method in our new dose engine, instead of the dose planning method employed in gDPM. Dose distributions were calculated for a 15 MeV electron beam and a 6 MV photon beam in a homogenous water phantom, a water-bone-lung-water slab phantom and a half-slab phantom. Satisfactory agreement between the two MC dose engines goMC and gDPM was observed in all cases. The average dose differences in the regions that received a dose higher than 10% of the maximum dose were 0.48-0.53% for the electron beam cases and 0.15-0.17% for the photon beam cases. In terms of efficiency, goMC was ~4-16% slower than gDPM when running on the same NVidia TITAN card for all the cases we tested, due to both the different electron transport models and the different development environments. The code portability of our new dose engine goMC was validated by successfully running it on a variety of different computing devices including an NVidia GPU card, two AMD GPU cards and an Intel CPU processor. Computational efficiency among these platforms was compared.
A GPU OpenCL based cross-platform Monte Carlo dose calculation engine (goMC).
Tian, Zhen; Shi, Feng; Folkerts, Michael; Qin, Nan; Jiang, Steve B; Jia, Xun
2015-10-07
Monte Carlo (MC) simulation has been recognized as the most accurate dose calculation method for radiotherapy. However, the extremely long computation time impedes its clinical application. Recently, a lot of effort has been made to realize fast MC dose calculation on graphic processing units (GPUs). However, most of the GPU-based MC dose engines have been developed under NVidia's CUDA environment. This limits the code portability to other platforms, hindering the introduction of GPU-based MC simulations to clinical practice. The objective of this paper is to develop a GPU OpenCL based cross-platform MC dose engine named goMC with coupled photon-electron simulation for external photon and electron radiotherapy in the MeV energy range. Compared to our previously developed GPU-based MC code named gDPM (Jia et al 2012 Phys. Med. Biol. 57 7783-97), goMC has two major differences. First, it was developed under the OpenCL environment for high code portability and hence could be run not only on different GPU cards but also on CPU platforms. Second, we adopted the electron transport model used in EGSnrc MC package and PENELOPE's random hinge method in our new dose engine, instead of the dose planning method employed in gDPM. Dose distributions were calculated for a 15 MeV electron beam and a 6 MV photon beam in a homogenous water phantom, a water-bone-lung-water slab phantom and a half-slab phantom. Satisfactory agreement between the two MC dose engines goMC and gDPM was observed in all cases. The average dose differences in the regions that received a dose higher than 10% of the maximum dose were 0.48-0.53% for the electron beam cases and 0.15-0.17% for the photon beam cases. In terms of efficiency, goMC was ~4-16% slower than gDPM when running on the same NVidia TITAN card for all the cases we tested, due to both the different electron transport models and the different development environments. The code portability of our new dose engine goMC was validated by successfully running it on a variety of different computing devices including an NVidia GPU card, two AMD GPU cards and an Intel CPU processor. Computational efficiency among these platforms was compared.
Cancer Deaths due to Lack of Universal Access to Radiotherapy in the Brazilian Public Health System.
Mendez, L C; Moraes, F Y; Fernandes, G Dos S; Weltman, E
2018-01-01
Radiotherapy plays a fundamental role in the treatment of cancer. Currently, the Brazilian public health system cannot match the national radiotherapy demand and many patients requiring radiotherapy are never exposed to this treatment. This study estimated the number of preventable deaths in the public health system if access to radiotherapy was universal. Incidence rates for the year 2016 provided by Instituto Nacional de Cancer were used in this analysis. The number of untreated patients requiring radiotherapy was obtained through the difference between the total number of patients requiring radiotherapy and the total amount of delivered radiotherapy treatments in the public health system. The number of deaths for the three most common cancers in each gender due to radiotherapy shortage was calculated. Initially, the total number of patients per cancer type was divided in stages using Brazilian epidemiological data. Subsequently, previously published tree arm diagrams were used to define the rate of patients requiring radiotherapy in each specific clinical setting. Finally, the clinical benefit of radiotherapy in overall survival was extracted from studies with level 1 evidence. Over 596 000 cancer cases were expected in Brazil in 2016. The public health system covers more than 75% of the Brazilian population and an estimated 111 432 patients who required radiotherapy in 2016 did not receive this treatment. Breast, colorectal and cervix cancers are the most frequent malignant tumours in women and prostate, lung and colorectal in men. The number of deaths due to a radiotherapy shortage in the year 2016 for these types of cancer were: (i) breast: 1011 deaths in 10 years; (ii) cervix: 2006 deaths in 2 years; (iii) lung: 1206 deaths in 2 years; (iv) prostate, intermediate risk: 562 deaths in 13 years; high risk: 298 deaths in 10 years; (v) colorectal: 0 deaths, as radiotherapy has no proven benefit in overall survival. Thousands of cancer patients requiring radiotherapy do not have access to this treatment in the Brazilian public health system. The shortage of radiotherapy has a significant detrimental effect on cancer survival; over 5000 deaths would probably be prevented in the most common cancer types if radiotherapy access was universal. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Post-radiotherapy hypothyroidism in dogs treated for thyroid carcinomas.
Amores-Fuster, I; Cripps, P; Blackwood, L
2017-03-01
Hypothyroidism is a common adverse event after head and neck radiotherapy in human medicine, but uncommonly reported in canine patients. Records of 21 dogs with histologically or cytologically confirmed thyroid carcinoma receiving definitive or hypofractionated radiotherapy were reviewed. Nine cases received 48 Gy in 12 fractions, 10 received 36 Gy in 4 fractions and 2 received 32 Gy in 4 fractions. Seventeen cases had radiotherapy in a post-operative setting. Ten cases developed hypothyroidism (47.6%) after radiotherapy. The development of hypothyroidism was not associated with the radiotherapy protocol used. Median time to diagnosis of hypothyroidism was 6 months (range, 1-13 months). Hypothyroidism is a common side effect following radiotherapy for thyroid carcinomas. Monitoring of thyroid function following radiotherapy is recommended. No specific risk factors have been identified. © 2015 John Wiley & Sons Ltd.
Biology of high single doses of IORT: RBE, 5 R's, and other biological aspects.
Herskind, Carsten; Ma, Lin; Liu, Qi; Zhang, Bo; Schneider, Frank; Veldwijk, Marlon R; Wenz, Frederik
2017-01-19
Intraoperative radiotherapy differs from conventional, fractionated radiotherapy in several aspects that may influence its biological effect. The radiation quality influences the relative biologic effectiveness (RBE), and the role of the five R's of radiotherapy (reassortment, repair, reoxygenation, repopulation, radiosensitivity) is different. Furthermore, putative special biological effects and the small volume receiving a high single dose may be important. The present review focuses on RBE, repair, and repopulation, and gives an overview of the other factors that potentially contribute to the efficacy. The increased RBE should be taken into account for low-energy X-rays while evidence of RBE < 1 for high-energy electrons at higher doses is presented. Various evidence supports a hypothesis that saturation of the primary DNA double-strand break (DSB) repair mechanisms leads to increasing use of an error-prone backup repair system leading to genomic instability that may contribute to inactivate tumour cells at high single doses. Furthermore, the elimination of repopulation of residual tumour cells in the tumour bed implies that some patients are likely to have very few residual tumour cells which may be cured even by low doses to the tumour bed. The highly localised dose distribution of IORT has the potential to inactivate tumour cells while sparing normal tissue by minimising the volume exposed to high doses. Whether special effects of high single doses also contribute to the efficacy will require further experimental and clinical studies.
Hu, Pengcheng; Cheng, Dengfeng; Huang, Tao; Banizs, Anna B; Xiao, Jie; Liu, Guobing; Chen, Quan; Wang, Yuenan; He, Jiang; Shi, Hongcheng
2017-09-06
Radiation therapy of liver cancer is limited by low tolerance of the liver to radiation. Radiosensitizers can effectively reduce the required radiation dose. AGuIX nanoparticles are small, multifunctional gadolinium-based nanoparticles that can carry radioisotopes or fluorescent markers for single-photon emission computed tomography (SPECT), positron emission tomography (PET), fluorescence imaging, and even multimodality imaging. In addition, due to the high atomic number of gadolinium, it can also serve as a tumor radiation sensitizer. It is critical to define the biodistribution and pharmacokinetics of these gadolinium-based nanoparticles to quantitate the magnitude and duration of their retention within the tumor microenvironment during radiotherapy. Therefore, in this study, we successfully labeled AGuIX with 64 Cu through the convenient built-in chelator. The biodistribution studies indicated that the radiotracer 64 Cu-AGuIX accumulates to high levels in the HepG2 xenograft of nude mice, suggesting that it would be a potential theranostic nanoprobe for image-guided radiotherapy in HCC. We also used a transmission electron microscope to confirm AGuIX uptake in the HepG2 cells. In radiation therapy studies, a decrease in 18 F-FDG uptake was observed in the xenografts of the nude mice irradiated with AGuIX, which was injected 1 h before. These results provide proof-of-concept that AGuIX can be used as a theranostic radiosensitizer for PET imaging to guide radiotherapy for liver cancer.
NASA Astrophysics Data System (ADS)
Hu, Pengcheng; Cheng, Dengfeng; Huang, Tao; Banizs, Anna B.; Xiao, Jie; Liu, Guobing; Chen, Quan; Wang, Yuenan; He, Jiang; Shi, Hongcheng
2017-09-01
Radiation therapy of liver cancer is limited by low tolerance of the liver to radiation. Radiosensitizers can effectively reduce the required radiation dose. AGuIX nanoparticles are small, multifunctional gadolinium-based nanoparticles that can carry radioisotopes or fluorescent markers for single-photon emission computed tomography (SPECT), positron emission tomography (PET), fluorescence imaging, and even multimodality imaging. In addition, due to the high atomic number of gadolinium, it can also serve as a tumor radiation sensitizer. It is critical to define the biodistribution and pharmacokinetics of these gadolinium-based nanoparticles to quantitate the magnitude and duration of their retention within the tumor microenvironment during radiotherapy. Therefore, in this study, we successfully labeled AGuIX with 64Cu through the convenient built-in chelator. The biodistribution studies indicated that the radiotracer 64Cu-AGuIX accumulates to high levels in the HepG2 xenograft of nude mice, suggesting that it would be a potential theranostic nanoprobe for image-guided radiotherapy in HCC. We also used a transmission electron microscope to confirm AGuIX uptake in the HepG2 cells. In radiation therapy studies, a decrease in 18F-FDG uptake was observed in the xenografts of the nude mice irradiated with AGuIX, which was injected 1 h before. These results provide proof-of-concept that AGuIX can be used as a theranostic radiosensitizer for PET imaging to guide radiotherapy for liver cancer.
Kumar, A Sathish; Singh, I Rabi Raja; Sharma, S D; Ravindran, B Paul
2015-01-01
The main objective of this study was to investigate the characteristics of metal oxide semiconductor field effect transistor (MOSFET) dosimeter for kilovoltage (kV) X-ray beams in order to perform the in vivo dosimetry during image guidance in radiotherapy. The performance characteristics of high sensitivity MOSFET dosimeters were investigated for 80, 90, 100, 110, 120, and 125 kV X-ray beams used for imaging in radiotherapy. This study was performed using Clinac 2100 C/D medical electron linear accelerator with on-board imaging and kV cone beam computed tomography system. The characteristics studied in this work include energy dependence, angular dependence, and linearity. The X-ray beam outputs were measured as per American Association of Physicists in Medicine (AAPM) TG 61 recommendations using PTW parallel plate (PP) ionization chamber, which was calibrated in terms of air kerma (Nk) by the National Standard Laboratory. The MOSFET dosimeters were calibrated against the PP ionization chamber for all the kV X-ray beams and the calibration coefficient was found to be 0.11 cGy/mV with a standard deviation of about ±1%. The response of MOSFET was found to be energy independent for the kV X-ray energies used in this study. The response of the MOSFET dosimeter was also found independent of angle of incidence for the gantry angles in the range of 0° to 360° in-air as well as at 3 cm depth in tissue equivalent phantom.
Wang, Yang; Fang, Jian; Nie, Jun; Dai, Ling; Hu, Weiheng; Zhang, Jie; Ma, Xiangjuan; Han, Jindi; Chen, Xiaoling; Tian, Guangming; Wu, Di; Han, Sen; Long, Jieran
2016-08-20
Radiotherapy combined with chemotherapy or molecular targeted therapy remains the standard of treatment for brain metastases from non-small cell lung cancer (NSCLC). The aim of this study is to determine if the deferral of brain radiotherapy impacts patient outcomes. Between May 2003 and December 2015, a total of 198 patients with brain metastases from NSCLC who received both brain radiotherapy and systemic therapy (chemotherapy or targeted therapy) were identified. The rate of grade 3-4 adverse reactions related to chemotherapy and radiotherapy had no significant difference between two groups. 127 patients received concurrent brain radiotherapy and systemic therapy, and 71 patients received deferred brain radiotherapy after at least two cycles of chemotherapy or targeted therapy. Disease specific-graded prognostic assessment was similar in early radiotherapy group and deferred radiotherapy group. Median overall survival (OS) was longer in early radiotherapy group compared to deferred radiotherapy group (17.9 months vs 12.6 months; P=0.038). Progression free survival (PFS) was also improved in patients receiving early radiotherapy compared to those receiving deferred radiotherapy (4.0 months vs 3.0 months; P<0.01). Receiving tyrosine kinase inhibitor (TKI) therapy after the diagnosis of brain metastases as any line therapy improved the OS (20.0 months vs 10.7 months; P<0.01), whereas receiving TKI as first line therapy did not (17.9 months vs 15.2 months; P=0.289). Our study suggests that the use of deferred brain radiotherapy may resulted in inferior OS in patients with NSCLC who develop brain metastases. A prospective multi-central randomized study is imminently needed.
Radiotherapy access in Belgium: How far are we from evidence-based utilisation?
Lievens, Y; De Schutter, H; Stellamans, K; Rosskamp, M; Van Eycken, L
2017-10-01
Underutilisation of radiotherapy has been observed worldwide. To evaluate the current situation in Belgium, optimal utilisation proportions (OUPs) adopted from the European SocieTy for Radiotherapy and Oncology - Health Economics in Radiation Oncology (ESTRO-HERO) project were compared to actual utilisation proportions (AUPs) and with radiotherapy advised during the multidisciplinary cancer team (MDT) meetings. In addition, the impact of independent variables was analysed. AUPs and advised radiotherapy were calculated overall and by cancer type for 110,810 unique cancer diagnoses in 2009-2010. Radiotherapy utilisation was derived from reimbursement data and distinguished between palliative and curative intent external beam radiotherapy (EBRT) and/or brachytherapy (BT). Sensitivity analyses regarding the influence of the follow-up period, the survival length and patient's age were performed. Advised radiotherapy was calculated based on broad treatment categories as reported at MDT meetings. The overall AUP of 37% (39% including BT) was lower than the OUP of 53%, but in line with advised radiotherapy (35%). Large variations by tumour type were observed: in some tumours (e.g. lung and prostate cancer) AUP was considerably lower than OUP, whereas in others there was reasonable concordance (e.g. breast and rectal cancer). Overall, 84% of treatments started within 9 months following diagnosis. Survival time influenced AUP in a cancer type-dependent way. Elderly patients received less radiotherapy. Although the actually delivered radiotherapy in Belgium aligns well to MDT advices, it is lower than the evidence-based optimum. Further analysis of potential barriers is needed for radiotherapy forecasting and planning, and in order to promote adequate access to radiotherapy. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhu, Jingyi; Zhao, Lingzhou; Cheng, Yongjun; Xiong, Zhijuan; Tang, Yueqin; Shen, Mingwu; Zhao, Jinhua; Shi, Xiangyang
2015-10-01
We report the synthesis, characterization, and utilization of radioactive 131I-labeled multifunctional dendrimers for targeted single-photon emission computed tomography (SPECT) imaging and radiotherapy of tumors. In this study, amine-terminated poly(amidoamine) dendrimers of generation 5 (G5.NH2) were sequentially modified with 3-(4'-hydroxyphenyl)propionic acid-OSu (HPAO) and folic acid (FA) linked with polyethylene glycol (PEG), followed by acetylation modification of the dendrimer remaining surface amines and labeling of radioactive iodine-131 (131I). The generated multifunctional 131I-G5.NHAc-HPAO-PEG-FA dendrimers were characterized via different methods. We show that prior to 131I labeling, the G5.NHAc-HPAO-PEG-FA dendrimers conjugated with approximately 9.4 HPAO moieties per dendrimer are noncytotoxic at a concentration up to 20 μM and are able to target cancer cells overexpressing FA receptors (FAR), thanks to the modified FA ligands. In the presence of a phenol group, radioactive 131I is able to be efficiently labeled onto the dendrimer platform with good stability and high radiochemical purity, and render the platform with an ability for targeted SPECT imaging and radiotherapy of an FAR-overexpressing xenografted tumor model in vivo. The designed strategy to use the facile dendrimer nanotechnology may be extended to develop various radioactive theranostic nanoplatforms for targeted SPECT imaging and radiotherapy of different types of cancer.We report the synthesis, characterization, and utilization of radioactive 131I-labeled multifunctional dendrimers for targeted single-photon emission computed tomography (SPECT) imaging and radiotherapy of tumors. In this study, amine-terminated poly(amidoamine) dendrimers of generation 5 (G5.NH2) were sequentially modified with 3-(4'-hydroxyphenyl)propionic acid-OSu (HPAO) and folic acid (FA) linked with polyethylene glycol (PEG), followed by acetylation modification of the dendrimer remaining surface amines and labeling of radioactive iodine-131 (131I). The generated multifunctional 131I-G5.NHAc-HPAO-PEG-FA dendrimers were characterized via different methods. We show that prior to 131I labeling, the G5.NHAc-HPAO-PEG-FA dendrimers conjugated with approximately 9.4 HPAO moieties per dendrimer are noncytotoxic at a concentration up to 20 μM and are able to target cancer cells overexpressing FA receptors (FAR), thanks to the modified FA ligands. In the presence of a phenol group, radioactive 131I is able to be efficiently labeled onto the dendrimer platform with good stability and high radiochemical purity, and render the platform with an ability for targeted SPECT imaging and radiotherapy of an FAR-overexpressing xenografted tumor model in vivo. The designed strategy to use the facile dendrimer nanotechnology may be extended to develop various radioactive theranostic nanoplatforms for targeted SPECT imaging and radiotherapy of different types of cancer. Electronic supplementary information (ESI) available: Part of the experimental details and additional experimental results. See DOI: 10.1039/c5nr05585g
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batumalai, Vikneswary, E-mail: vikneswary.batumalai@sswahs.nsw.gov.au; South Western Clinical School, University of New South Wales, Sydney, New South Wales; Quinn, Alexandra
Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying breast size in breast radiotherapy. Planning computed tomography (CT) data sets of 30 breast cancer patients were utilised to simulate the dose received by various organs from a megavoltage computed tomography (MV-CT), megavoltage electronic portal image (MV-EPI) and megavoltage cone-beam computed tomography (MV-CBCT). Themore » mean dose to organs adjacent to the target volume (contralateral breast, lungs, spinal cord and heart) were analysed. Pearson correlation analysis was performed to determine the relationship between imaging dose and primary breast volume and the lifetime attributable risk (LAR) of induced secondary cancer was calculated for the contralateral breast. The highest contralateral breast mean dose was from the MV-CBCT (1.79 Gy), followed by MV-EPI (0.22 Gy) and MV-CT (0.11 Gy). A similar trend was found for all organs at risk (OAR) analysed. The primary breast volume inversely correlated with the contralateral breast dose for all three imaging modalities. As the primary breast volume increases, the likelihood of a patient developing a radiation-induced secondary cancer to the contralateral breast decreases. MV-CBCT showed a stronger relationship between breast size and LAR of developing a radiation-induced contralateral breast cancer in comparison with the MV-CT and MV-EPI. For breast patients, imaging dose to OAR depends on imaging modality and treated breast size. When considering the use of imaging during breast radiotherapy, the patient's breast size and contralateral breast dose should be taken into account.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, I-Chow, E-mail: ihsu@radonc.ucsf.ed; Bae, Kyounghwa; Shinohara, Katsuto
2010-11-01
Purpose: To estimate the rate of late Grade 3 or greater genitourinary (GU) and gastrointestinal (GI) adverse events (AEs) after treatment with external beam radiotherapy and prostate high-dose-rate (HDR) brachytherapy. Methods and Materials: Each participating institution submitted computed tomography-based HDR brachytherapy dosimetry data electronically for credentialing and for each study patient. Patients with locally confined Stage T1c-T3b prostate cancer were eligible for the present study. All patients were treated with 45 Gy in 25 fractions using external beam radiotherapy and one HDR implant delivering 19 Gy in two fractions. All AEs were graded according to the Common Terminology Criteria formore » Adverse Events, version 3.0. Late GU/GI AEs were defined as those occurring >9 months from the start of the protocol treatment, in patients with {>=}18 months of potential follow-up. Results: A total of 129 patients from 14 institutions were enrolled in the present study. Of the 129 patients, 125 were eligible, and AE data were available for 112 patients at analysis. The pretreatment characteristics of the patients were as follows: Stage T1c-T2c, 91%; Stage T3a-T3b, 9%; prostate-specific antigen level {<=}10 ng/mL, 70%; prostate-specific antigen level >10 but {<=}20 ng/mL, 30%; and Gleason score 2-6, 10%; Gleason score 7, 72%; and Gleason score 8-10, 18%. At a median follow-up of 29.6 months, three acute and four late Grade 3 GU/GI AEs were reported. The estimated rate of late Grade 3-5 GU and GI AEs at 18 months was 2.56%. Conclusion: This is the first prospective, multi-institutional trial of computed tomography-based HDR brachytherapy and external beam radiotherapy. The technique and doses used in the present study resulted in acceptable levels of AEs.« less
Bai, Yanxia; Yan, Liying; Zhang, Shaoqiang; Shao, Yuan; Yao, Xiaobao; Li, Honghui; Zhao, Ruimin; Zhao, Qian; Zhang, Pengfei; Yang, Qi
2014-09-01
To observe the short-term and long-term curative effect of the xenogenic acellular dermal matrix membrane (or joint muscle flap transfer) application used in the 82 cases postoperative tissue shortage repair that after the head neck carcinoma resection. To held the 82 cases head neck carcinoma postoperative mucosa shortage repaired after resection by the xenogenic acellular dermal matrix membrane (or joint muscle flap transfer), 65 cases mucosa shortage wound be directly covered by the repair membrane and the other 17 cases mucosa shortage wound be repaired by the tranfered muscle tissue flap with the repair membrane covered; 53 cases underwent additional postoperative radiotherapy between 2-4 weeks and follow-up in 1, 3, 6, 12, 18, 24, 30, 36, 48, 60 months and observed the operation site repair process through the electronic laryngoscope, observed the patients respiration, swallow, phonation function. Seventy-seven cases patients operation incision reached I phase healing standard, another 5 cases patients operation incision reached II phase healing standard because of the wound infection and fully-recovered through the local wound drainage,dressing process. All the patients tracheal cannula,the stomach tube be extubated successfully and without the local cicatricial constriction occurred. Seventy-eight cases follow up period reached 1 year including 53 cases who underwent postoperative radiotherapy, 49 cases follow up period reached 3 years including 32 cases who underwent postoperative radiotherapy, 14 cases follow up period reached 5 years including 12 cases who underwent postoperative radiotherapy. The patients with static local lesions discovered no reaction such as exclusion, allergy. The application of xenogenic acellular dermal matrix membrane (or joint muscle flap transfer used in in the postoperative tissue shortage repair that after the head neck carcinoma resection have several advantage such as comparatively easily implementation, operation safety edge enough,well preserved organ function, comparatively low incidence about the laryngeal stenosis, the short-term and long-term repair effect are all exact.
Cosmetic outcome 1-5 years after breast conservative surgery, irradiation and systemic therapy.
Kelemen, Gyöngyi; Varga, Zoltán; Lázár, György; Thurzó, László; Kahán, Zsuzsanna
2012-04-01
The late side-effects of the local therapy of early breast cancer depend on many patient- and therapy-related parameters. We aimed at investigating the factors that influence the cosmetic and functional outcomes among our breast cancer patients after breast-conserving surgery and conformal radiotherapy, with or without adjuvant systemic therapy. A study was made of the association of the cosmetic outcome after a median follow-up time of 2.4 years and the clinical data on 198 patients extracted from a prospectively compiled database. Breast tenderness occurred more frequently among patients ≤50 years old (p < 0.05). Long-term side effects were related to radiotherapy-related factors the most, while no effect of the systemic therapy could be detected. The risk of hyperpigmentation, breast edema and breast fibrosis increased by 18%, 23% and 7%, respectively for every 100 cm(3) increase in the irradiated breast volume, while that of breast edema and breast fibrosis increased by 21% and 12%, respectively for every 10 cm(3) increase in the boost volume. Patients who received a photon boost were significantly more likely to develop breast edema and fibrosis than those who received electrons (p < 0.005). Dose inhomogeneity was related to the volume of the irradiated breast (p = 0.037). Dyspigmentation developed more often among patients older than 50 years, while smoking favoured both dyspigmentation and teleangiectasia. Breast edema was related to dyspigmentation (p = 0.003), fibrosis (p < 0.001) and breast asymmetry (p = 0.032), whereas none of these abnormalities were associated with teleangiectasia. Body image changes were more frequent at a younger age (p < 0.005), while the need to change clothing habits occurred more often at an older age (p < 0.05). Radiotherapy-related parameters appear to exert the greatest effect on the overall cosmetic outcome after breast-conserving surgery and postoperative radiotherapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
St Aubin, J., E-mail: joel.st.aubin@albertahealthservices.ca; Keyvanloo, A.; Fallone, B. G.
Purpose: The advent of magnetic resonance imaging (MRI) guided radiotherapy systems demands the incorporation of the magnetic field into dose calculation algorithms of treatment planning systems. This is due to the fact that the Lorentz force of the magnetic field perturbs the path of the relativistic electrons, hence altering the dose deposited by them. Building on the previous work, the authors have developed a discontinuous finite element space-angle treatment of the linear Boltzmann transport equation to accurately account for the effects of magnetic fields on radiotherapy doses. Methods: The authors present a detailed description of their new formalism and comparemore » its accuracy to GEANT4 Monte Carlo calculations for magnetic fields parallel and perpendicular to the radiation beam at field strengths of 0.5 and 3 T for an inhomogeneous 3D slab geometry phantom comprising water, bone, and air or lung. The accuracy of the authors’ new formalism was determined using a gamma analysis with a 2%/2 mm criterion. Results: Greater than 98.9% of all points analyzed passed the 2%/2 mm gamma criterion for the field strengths and orientations tested. The authors have benchmarked their new formalism against Monte Carlo in a challenging radiation transport problem with a high density material (bone) directly adjacent to a very low density material (dry air at STP) where the effects of the magnetic field dominate collisions. Conclusions: A discontinuous finite element space-angle approach has been proven to be an accurate method for solving the linear Boltzmann transport equation with magnetic fields for cases relevant to MRI guided radiotherapy. The authors have validated the accuracy of this novel technique against GEANT4, even in cases of strong magnetic field strengths and low density air.« less
The feasibility of using Microsoft Kinect v2 sensors during radiotherapy delivery.
Edmunds, David M; Bashforth, Sophie E; Tahavori, Fatemeh; Wells, Kevin; Donovan, Ellen M
2016-11-08
Consumer-grade distance sensors, such as the Microsoft Kinect devices (v1 and v2), have been investigated for use as marker-free motion monitoring systems for radiotherapy. The radiotherapy delivery environment is challenging for such sen-sors because of the proximity to electromagnetic interference (EMI) from the pulse forming network which fires the magnetron and electron gun of a linear accelerator (linac) during radiation delivery, as well as the requirement to operate them from the control area. This work investigated whether using Kinect v2 sensors as motion monitors was feasible during radiation delivery. Three sensors were used each with a 12 m USB 3.0 active cable which replaced the supplied 3 m USB 3.0 cable. Distance output data from the Kinect v2 sensors was recorded under four condi-tions of linac operation: (i) powered up only, (ii) pulse forming network operating with no radiation, (iii) pulse repetition frequency varied between 6 Hz and 400 Hz, (iv) dose rate varied between 50 and 1450 monitor units (MU) per minute. A solid water block was used as an object and imaged when static, moved in a set of steps from 0.6 m to 2.0 m from the sensor and moving dynamically in two sinusoidal-like trajectories. Few additional image artifacts were observed and there was no impact on the tracking of the motion patterns (root mean squared accuracy of 1.4 and 1.1mm, respectively). The sensors' distance accuracy varied by 2.0 to 3.8 mm (1.2 to 1.4 mm post distance calibration) across the range measured; the precision was 1 mm. There was minimal effect from the EMI on the distance calibration data: 0 mm or 1 mm reported distance change (2 mm maximum change at one position). Kinect v2 sensors operated with 12 m USB 3.0 active cables appear robust to the radiotherapy treatment environment. © 2016 The Authors.
NASA Astrophysics Data System (ADS)
Gustafsson, C.; Nordström, F.; Persson, E.; Brynolfsson, J.; Olsson, L. E.
2017-04-01
Dosimetric errors in a magnetic resonance imaging (MRI) only radiotherapy workflow may be caused by system specific geometric distortion from MRI. The aim of this study was to evaluate the impact on planned dose distribution and delineated structures for prostate patients, originating from this distortion. A method was developed, in which computer tomography (CT) images were distorted using the MRI distortion field. The displacement map for an optimized MRI treatment planning sequence was measured using a dedicated phantom in a 3 T MRI system. To simulate the distortion aspects of a synthetic CT (electron density derived from MR images), the displacement map was applied to CT images, referred to as distorted CT images. A volumetric modulated arc prostate treatment plan was applied to the original CT and the distorted CT, creating a reference and a distorted CT dose distribution. By applying the inverse of the displacement map to the distorted CT dose distribution, a dose distribution in the same geometry as the original CT images was created. For 10 prostate cancer patients, the dose difference between the reference dose distribution and inverse distorted CT dose distribution was analyzed in isodose level bins. The mean magnitude of the geometric distortion was 1.97 mm for the radial distance of 200-250 mm from isocenter. The mean percentage dose differences for all isodose level bins, were ⩽0.02% and the radiotherapy structure mean volume deviations were <0.2%. The method developed can quantify the dosimetric effects of MRI system specific distortion in a prostate MRI only radiotherapy workflow, separated from dosimetric effects originating from synthetic CT generation. No clinically relevant dose difference or structure deformation was found when 3D distortion correction and high acquisition bandwidth was used. The method could be used for any MRI sequence together with any anatomy of interest.
Gustafsson, C; Nordström, F; Persson, E; Brynolfsson, J; Olsson, L E
2017-04-21
Dosimetric errors in a magnetic resonance imaging (MRI) only radiotherapy workflow may be caused by system specific geometric distortion from MRI. The aim of this study was to evaluate the impact on planned dose distribution and delineated structures for prostate patients, originating from this distortion. A method was developed, in which computer tomography (CT) images were distorted using the MRI distortion field. The displacement map for an optimized MRI treatment planning sequence was measured using a dedicated phantom in a 3 T MRI system. To simulate the distortion aspects of a synthetic CT (electron density derived from MR images), the displacement map was applied to CT images, referred to as distorted CT images. A volumetric modulated arc prostate treatment plan was applied to the original CT and the distorted CT, creating a reference and a distorted CT dose distribution. By applying the inverse of the displacement map to the distorted CT dose distribution, a dose distribution in the same geometry as the original CT images was created. For 10 prostate cancer patients, the dose difference between the reference dose distribution and inverse distorted CT dose distribution was analyzed in isodose level bins. The mean magnitude of the geometric distortion was 1.97 mm for the radial distance of 200-250 mm from isocenter. The mean percentage dose differences for all isodose level bins, were ⩽0.02% and the radiotherapy structure mean volume deviations were <0.2%. The method developed can quantify the dosimetric effects of MRI system specific distortion in a prostate MRI only radiotherapy workflow, separated from dosimetric effects originating from synthetic CT generation. No clinically relevant dose difference or structure deformation was found when 3D distortion correction and high acquisition bandwidth was used. The method could be used for any MRI sequence together with any anatomy of interest.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, F.Q; Chen, Z; Nath, R
Purpose: To investigate the current status of clinical usage of cochlear implant (CI) and other bionic devices (BD) in the brain and head and neck regions (BH and N) and their management in patients during radiotherapy to ensure patient health and safety as well as optimum radiation delivery. Methods: Literature review was performed with both CIs and radiotherapy and their variants as keywords in PubMed, INSPEC and other sources. The focus was on CIs during radiotherapy, but it also included other BDs in BHȦN, such as auditory brainstem implant, bionic retinal implant, and hearing aids, among others. Results: Interactions betweenmore » CIs and radiation may cause CIs malfunction. The presence of CIs may also cause suboptimum dose distribution if a treatment plan was not well designed. A few studies were performed for the hearing functions of CIs under irradiations of 4 MV and 6 MV x-rays. However, x-rays with higher energies (10 to 18 MV) broadly used in radiotherapy have not been explored. These higher energetic beams are more damaging to electronics due to strong penetrating power and also due to neutrons generated in the treatment process. Modern CIs are designed with more and more complicated integrated circuits, which may be more susceptible to radiation damage and malfunction. Therefore, careful management is important for safety and treatment outcomes. Conclusion: Although AAPM TG-34, TG-63, and TG-203 (update of TG-34, not published yet) reports may be referenced for management of CIs and other BDs in the brain and H and N regions, a site- and device-specified guideline should be developed for CIs and other BDs. Additional evaluation of CI functions under clinically relevant set-ups should also be performed to provide clinicians with better knowledge in clinical decision making.« less
Gao, Li; Hu, Yuejian; Wang, Yuxia; Jiang, Wenxin; He, Zhiyan; Zhu, Cailian; Ma, Rui; Huang, Zhengwei
2015-09-01
The aim of this article was to study the variation in oral microflora of the subgingival plaque during and after radiotherapy. During and after radiotherapy, microbial samples were collected at seven time points (early stage, medium stage, and later stage of radiotherapy, and 1 month, 3 months, 6 months, and 1 year after radiotherapy) in three subjects for a total of 21 samples. Polymerase chain reaction (PCR) amplification was carried out on the 16S rDNA hypervariable V1-V3 region, and then the PCR products were determined by high-throughput pyrosequencing. The rarefaction curve indicating the richness of the microflora demonstrated that the number of operational taxonomic units (OTUs) was in decline from the early stage of radiotherapy to the time point 1 month after radiotherapy and then trended upward. The Shannon diversity index declined during radiotherapy (ranging from 4.59 to 3.73), and generally rose after radiotherapy, with the lowest value of 3.5 (1 month after radiotherapy) and highest value of 4.75 (6 months after radiotherapy). A total of 120 genera were found; five genera (Actinomyces, Veillonella, Prevotella, Streptococcus, Campylobacter) were found in all subjects across all time points. The richness and diversity of oral ecology decreased with increased radiation dose, and it was gradually restored with time. Copyright © 2015 Elsevier Ltd. All rights reserved.
Adjuvant radiotherapy after breast conserving surgery - a comparative effectiveness research study.
Corradini, Stefanie; Niyazi, Maximilian; Niemoeller, Olivier M; Li, Minglun; Roeder, Falk; Eckel, Renate; Schubert-Fritschle, Gabriele; Scheithauer, Heike R; Harbeck, Nadia; Engel, Jutta; Belka, Claus
2015-01-01
The purpose of this retrospective outcome study was to validate the effectiveness of postoperative radiotherapy in breast conserving therapy (BCT) and to evaluate possible causes for omission of radiotherapy after breast conserving surgery (BCS) in a non-trial population. Data were provided by the population-based Munich Cancer Registry. The study included epidemiological data of 30.811 patients diagnosed with breast cancer from 1998 to 2012. The effect of omitting radiotherapy was analysed using Kaplan-Meier-estimates and Cox proportional hazard regression. Variables predicting omission of radiotherapy were analysed using multivariate logistic regression. Use of postoperative radiotherapy after BCS was associated with significant improvements in local control and survival. 10-year loco-regional recurrence-free-survival was 90.8% with postoperative radiotherapy vs. 77.6% with surgery alone (p<0.001). 10-year overall survival rates were 55.2% with surgery alone vs. 82.2% following postoperative radiotherapy (p<0.001). Variables predicting omission of postoperative radiotherapy included advanced age (women ⩾80 years; OR: 0.082; 95% CI: 0.071-0.094, p<0.001). This study shows a decrease in local control and a survival disadvantage if postoperative radiotherapy after breast conserving surgery is omitted in an unselected cohort of primary breast cancer patients. Due to its epidemiological nature, it cannot answer the question in whom postoperative radiotherapy can be safely omitted. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Matsumine, Akihiko; Tsujii, Masaya; Nakamura, Tomoki; Asanuma, Kunihiro; Matsubara, Takao; Kakimoto, Takuya; Yada, Yuki; Takada, Akinori; Ii, Noriko; Nomoto, Yoshihito; Sudo, Akihiro
2016-08-12
When a soft tissue sarcoma (STS) is located at the distal part of an extremity and involves the tendon, a wide excision usually causes severe functional disability. We therefore developed a minimally invasive surgical technique using intraoperative electron-beam radiotherapy (IOERT) to reduce the incidence of post-operative functional disability in patients with peri-/intra-tendinous STS. We assessed the clinical outcomes of the novel minimally invasive surgery. The study population included five patients who received treatment for distal extremity STSs. After elevating the tumor mass, including the tendon and nerve from the tumor bed with a wide margin, a lead board was inserted beneath the tumor mass to shield the normal tissue. IOERT (25-50 Gy) was then applied, and the tumor excised with care taken to maintain the continuity of the tendon. In a desmoid patient, local recurrence was observed outside the irradiated field. No cases of neuropathy or bone necrosis were observed. The mean limb function score was excellent in all patients. None of the high-grade sarcoma patients had local recurrence or distant metastasis. Although the current study is only a pilot study with a small number of patients, it shows that this minimally invasive procedure has the potential to become a standard treatment option for selected patients. H17-250 (registered 2 November 2005) and H25-250 (modified from H17-250, registered 5 December 2013).
Antolak, J A; Cundiff, J H; Ha, C S
1998-01-01
The purpose of this report is to discuss the utilization of thermoluminescent dosimetry (TLD) in total skin electron beam (TSEB) radiotherapy to: (a) compare patient dose distributions for similar techniques on different machines, (b) confirm beam calibration and monitor unit calculations, (c) provide data for making clinical decisions, and (d) study reasons for variations in individual dose readings. We report dosimetric results for 72 cases of mycosis fungoides, using similar irradiation techniques on two different linear accelerators. All patients were treated using a modified Stanford 6-field technique. In vivo TLD was done on all patients, and the data for all patients treated on both machines was collected into a database for analysis. Means and standard deviations (SDs) were computed for all locations. Scatter plots of doses vs. height, weight, and obesity index were generated, and correlation coefficients with these variables were computed. The TLD results show that our current TSEB implementation is dosimetrically equivalent to the previous implementation, and that our beam calibration technique and monitor unit calculation is accurate. Correlations with obesity index were significant at several sites. Individual TLD results allow us to customize the boost treatment for each patient, in addition to revealing patient positioning problems and/or systematic variations in dose caused by patient variability. The data agree well with previously published TLD results for similar TSEB techniques. TLD is an important part of the treatment planning and quality assurance programs for TSEB, and routine use of TLD measurements for TSEB is recommended.
Randomised trial of personalised computer based information for cancer patients
Jones, Ray; Pearson, Janne; McGregor, Sandra; Cawsey, Alison J; Barrett, Ann; Craig, Neil; Atkinson, Jacqueline M; Gilmour, W Harper; McEwen, Jim
1999-01-01
Objective To compare the use and effect of a computer based information system for cancer patients that is personalised using each patient's medical record with a system providing only general information and with information provided in booklets. Design Randomised trial with three groups. Data collected at start of radiotherapy, one week later (when information provided), three weeks later, and three months later. Participants 525 patients started radical radiotherapy; 438 completed follow up. Interventions Two groups were offered information via computer (personalised or general information, or both) with open access to computer thereafter; the third group was offered a selection of information booklets. Outcomes Patients' views and preferences, use of computer and information, and psychological status; doctors' perceptions; cost of interventions. Results More patients offered the personalised information said that they had learnt something new, thought the information was relevant, used the computer again, and showed their computer printouts to others. There were no major differences in doctors' perceptions of patients. More of the general computer group were anxious at three months. With an electronic patient record system, in the long run the personalised information system would cost no more than the general system. Full access to booklets cost twice as much as the general system. Conclusions Patients preferred computer systems that provided information from their medical records to systems that just provided general information. This has implications for the design and implementation of electronic patient record systems and reliance on general sources of patient information. PMID:10550090
Breast Cancer Patients’ Experience of External-Beam Radiotherapy
Schnur, Julie B.; Ouellette, Suzanne C.; Bovbjerg, Dana H.; Montgomery, Guy H.
2013-01-01
Radiotherapy is a critical component of treatment for the majority of women with breast cancer, particularly those who receive breast conserving surgery. Although medically beneficial, radiotherapy can take a physical and psychological toll on patients. However, little is known about the specific thoughts and feelings experienced by women undergoing breast cancer radiotherapy. Therefore, the study aim was to use qualitative research methods to develop an understanding of these thoughts and feelings based on 180 diary entries, completed during radiotherapy by 15 women with Stage 0-III breast cancer. Thematic analysis identified four primary participant concerns: (a) a preoccupation with time; (b) fantasies (both optimistic and pessimistic) about life following radiotherapy; (c) the toll their side-effect experience takes on their self-esteem; and (d) feeling mystified by radiotherapy. These themes are consistent with previous literature on illness and identity. These findings have implications for the treatment and care of women undergoing breast cancer radiotherapy. PMID:19380502
Outcome analysis of salvage radiotherapy for occult cervical cancer found after simple hysterectomy.
Koh, Hyeon Kang; Jeon, Wan; Kim, Hak Jae; Wu, Hong-Gyun; Kim, Kyubo; Chie, Eui Kyu; Ha, Sung W
2013-12-01
The objective was to analyze the outcomes of the patients, who received salvage radiotherapy for incidentally discovered cervical cancer following simple hysterectomy, and to identify the influence of intracavitary radiotherapy on treatment outcomes. Data from 117 patients with occult cervical cancer who underwent simple hysterectomy followed by salvage radiotherapy from September 1979 to November 2010 were collected. All the patients received external beam radiotherapy with (n = 45) or without (n = 72) intracavitary radiotherapy. Local control, disease-free survival, overall survival and treatment-related toxicity were investigated. The median follow-up time was 75 months. The 5- and 10-year local control/disease-free survival/overall survival rates were 93/87/87% and 90/84/83%, respectively. Among 98 patients who had no residual disease and negative resection margin on surgical specimens, 32 (33%) received intracavitary radiotherapy and 66 (67%) did not. There were no differences in patient and tumor characteristics between patients treated with and without intracavitary radiotherapy. The 5-year local control rate for the non-intracavitary radiotherapy group was 93 versus 94% for the intracavitary radiotherapy group (P = 0.564); the disease-free survival rate was 88 versus 94% (P = 0.894); the overall survival rate was 95 versus 85% (P = 0.106), respectively. Among all patients, there were 5% of Grade 3 or higher late toxicities. Patients with occult invasive cervical cancer discovered following simple hysterectomy could be treated safely and effectively with salvage radiotherapy. For patients with no residual disease and negative resection margin, intracavitary radiotherapy could be omitted.
Demand for radiotherapy in Spain.
Rodríguez, A; Borrás, J M; López-Torrecilla, J; Algara, M; Palacios-Eito, A; Gómez-Caamaño, A; Olay, L; Lara, P C
2017-02-01
Assessing the demand for radiotherapy in Spain based on existing evidence to estimate the human resources and equipment needed so that every person in Spain has access to high-quality radiotherapy when they need it. We used data from the European Cancer Observatory on the estimated incidence of cancer in Spain in 2012, along with the evidence-based indications for radiotherapy developed by the Australian CCORE project, to obtain an optimal radiotherapy utilisation proportion (OUP) for each tumour. About 50.5 % of new cancers in Spain require radiotherapy at least once over the course of the disease. Additional demand for these services comes from reradiation therapy and non-melanoma skin cancer. Approximately, 25-30 % of cancer patients with an indication for radiotherapy do not receive it due to factors that include access, patient preference, familiarity with the treatment among physicians, and especially resource shortages, all of which contribute to its underutilisation. Radiotherapy is underused in Spain. The increasing incidence of cancer expected over the next decade and the greater frequency of reradiations necessitate the incorporation of radiotherapy demand into need-based calculations for cancer services planning.
Combinations of Radiotherapy and Immunotherapy for Melanoma: A Review of Clinical Outcomes
Barker, Christopher A.; Postow, Michael A.
2015-01-01
Radiotherapy has long played a role in the management of melanoma. Recent advances have also demonstrated the efficacy of immunotherapy in the treatment of melanoma. Preclinical data suggest a biologic interaction between radiotherapy and immunotherapy. Several clinical studies corroborate these findings. This review will summarize the outcomes of studies reporting on patients with melanoma treated with a combination of radiotherapy and immunotherapy. Vaccine therapies often use irradiated melanoma cells, and may be enhanced by radiotherapy. The cytokines interferon-alpha and interleukin-2 have been combined with radiotherapy in several small studies, with some evidence suggesting increased toxicity and/or efficacy. Ipilimumab, a monoclonal antibody which blocks cytotoxic T-lymphocyte antigen-4, has been combined with radiotherapy in several notable case studies and series. Finally, pilot studies of adoptive cell transfer have suggested radiotherapy may improve the efficacy of treatment. The review will demonstrate that the combination of radiotherapy and immunotherapy has been reported in several notable case studies, series and clinical trials. These clinical results suggest interaction and the need for further study. PMID:24661650
Brushed permanent magnet DC MLC motor operation in an external magnetic field.
Yun, J; St Aubin, J; Rathee, S; Fallone, B G
2010-05-01
Linac-MR systems for real-time image-guided radiotherapy will utilize the multileaf collimators (MLCs) to perform conformal radiotherapy and tumor tracking. The MLCs would be exposed to the external fringe magnetic fields of the linac-MR hybrid systems. Therefore, an experimental investigation of the effect of an external magnetic field on the brushed permanent magnet DC motors used in some MLC systems was performed. The changes in motor speed and current were measured for varying external magnetic field strengths up to 2000 G generated by an EEV electromagnet. These changes in motor characteristics were measured for three orientations of the motor in the external magnetic field, mimicking changes in motor orientations due to installation and/or collimator rotations. In addition, the functionality of the associated magnetic motor encoder was tested. The tested motors are used with the Varian 120 leaf Millennium MLC (Maxon Motor half leaf and full leaf motors) and the Varian 52 leaf MKII MLC (MicroMo Electronics leaf motor) including a carriage motor (MicroMo Electronics). In most cases, the magnetic encoder of the motors failed prior to any damage to the gearbox or the permanent magnet motor itself. This sets an upper limit of the external magnetic field strength on the motor function. The measured limits of the external magnetic fields were found to vary by the motor type. The leaf motor used with a Varian 52 leaf MKII MLC system tolerated up to 450 +/- 10 G. The carriage motor tolerated up to 2000 +/- 10 G field. The motors used with the Varian 120 leaf Millennium MLC system were found to tolerate a maximum of 600 +/- 10 G. The current Varian MLC system motors can be used for real-time image-guided radiotherapy coupled to a linac-MR system, provided the fringe magnetic fields at their locations are below the determined tolerance levels. With the fringe magnetic fields of linac-MR systems expected to be larger than the tolerance levels determined, some form of magnetic shielding would be required.
NASA Astrophysics Data System (ADS)
Zhou, Min; Zhao, Jun; Tian, Mei; Song, Shaoli; Zhang, Rui; Gupta, Sanjay; Tan, Dongfeng; Shen, Haifa; Ferrari, Mauro; Li, Chun
2015-11-01
Tumor Initiating Cells (TICs) are resistant to radiotherapy and chemotherapy, and are believed to be responsible for tumor recurrence and metastasis. Combination therapies can overcome the limitation of conventional cancer treatments, and have demonstrated promising application in the clinic. Here, we show that dual modality radiotherapy (RT) and photothermal therapy (PTT) mediated by a single compartment nanosystem copper-64-labeled copper sulfide nanoparticles ([64Cu]CuS NPs) could suppress breast tumor metastasis through eradication of TICs. Positron electron tomography (PET) imaging and biodistribution studies showed that more than 90% of [64Cu]CuS NPs was retained in subcutaneously grown BT474 breast tumor 24 h after intratumoral (i.t.) injection, indicating the NPs are suitable for the combination therapy. Combined RT/PTT therapy resulted in significant tumor growth delay in the subcutaneous BT474 breast cancer model. Moreover, RT/PTT treatment significantly prolonged the survival of mice bearing orthotopic 4T1 breast tumors compared to no treatment, RT alone, or PTT alone. The RT/PTT combination therapy significantly reduced the number of tumor nodules in the lung and the formation of tumor mammospheres from treated 4T1 tumors. No obvious side effects of the CuS NPs were noted in the treated mice in a pilot toxicity study. Taken together, our data support the feasibility of a therapeutic approach for the suppression of tumor metastasis through localized RT/PTT therapy.Tumor Initiating Cells (TICs) are resistant to radiotherapy and chemotherapy, and are believed to be responsible for tumor recurrence and metastasis. Combination therapies can overcome the limitation of conventional cancer treatments, and have demonstrated promising application in the clinic. Here, we show that dual modality radiotherapy (RT) and photothermal therapy (PTT) mediated by a single compartment nanosystem copper-64-labeled copper sulfide nanoparticles ([64Cu]CuS NPs) could suppress breast tumor metastasis through eradication of TICs. Positron electron tomography (PET) imaging and biodistribution studies showed that more than 90% of [64Cu]CuS NPs was retained in subcutaneously grown BT474 breast tumor 24 h after intratumoral (i.t.) injection, indicating the NPs are suitable for the combination therapy. Combined RT/PTT therapy resulted in significant tumor growth delay in the subcutaneous BT474 breast cancer model. Moreover, RT/PTT treatment significantly prolonged the survival of mice bearing orthotopic 4T1 breast tumors compared to no treatment, RT alone, or PTT alone. The RT/PTT combination therapy significantly reduced the number of tumor nodules in the lung and the formation of tumor mammospheres from treated 4T1 tumors. No obvious side effects of the CuS NPs were noted in the treated mice in a pilot toxicity study. Taken together, our data support the feasibility of a therapeutic approach for the suppression of tumor metastasis through localized RT/PTT therapy. Electronic supplementary information (ESI) available: Details of methods used for radiolabeling efficiency and stability of 64Cu-labeled CuS NPs. See DOI: 10.1039/c5nr04587h
A cosmetic evaluation of breast cancer treatment: A randomized study of radiotherapy boost technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vass, Sylvie; Bairati, Isabelle
2005-08-01
Purpose: To compare cosmetic results of two different radiotherapy (RT) boost techniques used in the treatment of breast cancer after whole breast radiotherapy and to identify factors affecting cosmetic outcomes. Methods and Materials: Between 1996 and 1998, 142 patients with Stage I and II breast cancer were treated with breast conservative surgery and adjuvant RT. Patients were then randomly assigned to receive a boost dose of 15 Gy delivered to the tumor bed either by iridium 192, or a combination of photons and electrons. Cosmetic evaluations were done on a 6-month basis, with a final evaluation at 36 months aftermore » RT. The evaluations were done using a panel of global and specific subjective scores, a digitized scoring system using the breast retraction assessment (BRA) measurement, and a patient's self-assessment evaluation. As cosmetic results were graded according to severity, the comparison of boost techniques was done using the ordinal logistic regression model. Adjusted odds ratios (OR) and their 95% confidence intervals (CI) are presented. Results: At 36 months of follow-up, there was no significant difference between the two groups with respect to the global subjective cosmetic outcome (OR = 1.40; 95%CI = 0.69-2.85, p = 0.35). Good to excellent scores were observed in 65% of implant patients and 62% of photon/electron patients. At 24 months and beyond, telangiectasia was more severe in the implant group with an OR of 9.64 (95%CI = 4.05-22.92, p < 0.0001) at 36 months. The only variable associated with a worse global cosmetic outcome was the presence of concomitant chemotherapy (OR = 3.87; 95%CI = 1.74-8.62). The BRA value once adjusted for age, concomitant chemotherapy, and boost volume showed a positive association with the boost technique. The BRA value was significantly greater in the implant group (p 0.03). There was no difference in the patient's final self-assessment score between the two groups. Three variables were statistically associated with an adverse self-evaluation: an inferior quadrant tumor localization, postoperative hematoma, and concomitant chemotherapy. Conclusions: Although this trial showed that at 36 months of follow-up, there were no significant differences in the overall global cosmetic scores between the implant boost group and the photon/electron boost group, telangiectasia was more severe and the BRA value was greater in the implant group.« less
The role of intraoperative radiotherapy in solid tumors.
Skandarajah, A R; Lynch, A C; Mackay, J R; Ngan, S; Heriot, A G
2009-03-01
Combined multimodality therapy is becoming standard treatment for many solid tumors, but the role of intraoperative radiotherapy in the management of solid tumors remains uncertain. The aim is to review the indication, application, and outcomes of intraoperative radiotherapy in the management of nongynecological solid tumors. A literature search was performed using Medline, Embase, Ovid, and Cochrane database for studies between 1965 and 2008 assessing intraoperative radiotherapy, using the keywords "intraoperative radiotherapy," "colorectal cancer," "breast cancer," "gastric cancer," "pancreatic cancer," "soft tissue tumor," and "surgery." Only publications in English with available abstracts and regarding adult humans were included, and the evidence was critically evaluated. Our search retrieved 864 publications. After exclusion of nonclinical papers, duplicated papers and exclusion of brachytherapy papers, 77 papers were suitable to assess the current role of intraoperative radiotherapy. The clinical application and evidence base of intraoperative radiotherapy for each cancer is presented. Current studies in all common cancers show an additional benefit in local recurrence rates when intraoperative radiotherapy is included in the multimodal treatment. However, intraoperative radiotherapy may not improve overall survival and has significant morbidity depending on the site of the tumor. Intraoperative radiotherapy does have a role in the multidisciplinary management of solid tumors, but further studies are required to more precisely determine the extent of benefit.
Melatonin prevents possible radiotherapy-induced thyroid injury.
Arıcıgil, Mitat; Dündar, Mehmet Akif; Yücel, Abitter; Eryılmaz, Mehmet Akif; Aktan, Meryem; Alan, Mehmet Akif; Fındık, Sıdıka; Kılınç, İbrahim
2017-12-01
We aimed to investigate the protective effect of melatonin in radiotherapy-induced thyroid gland injury in an experimental rat model. Thirty-two rats were divided into four groups: the control group, melatonin treatment group, radiotherapy group and melatonin plus radiotherapy group. The neck region of each rat was defined by simulation and radiated with 2 Gray (Gy) per min with 6-MV photon beams, for a total dose of 18 Gy. Melatonin was administered at a dose of 50 mg/kg through intraperitoneal injection, 15 min prior to radiation exposure. Thirty days after the beginning of the study, rats were decapitated and analyses of blood and thyroid tissue were performed. Tumor necrosis factor-α (TNF-α), interleukin-1 beta (IL-1β), thiobarbituric acid reactive substances (TBARS) and nitric oxide (NO) levels in the radiotherapy group were significantly higher than those in the melatonin plus radiotherapy group (p < .05), whereas interleukin-10 (IL-10) and glutathione (GSH) values were higher in the melatonin plus radiotherapy group (p < .05). The infiltration of inflammatory cells and percentage of apoptosis in the radiotherapy group were significantly higher than those in the melatonin plus radiotherapy group (p < .05). Melatonin helped protect thyroid gland structure against the undesired cytotoxic effects of radiotherapy in rats.
Radiation therapy for people with cancer: what do written information materials tell them?
Smith, S K; Yan, B; Milross, C; Dhillon, H M
2016-07-01
This study aimed to compare and contrast the contents of different types of written patient information about radiotherapy, namely (1) hospital radiotherapy departments vs. cancer control organisations and (2) generic vs. tumour-specific materials. A coding framework, informed by existing patients' information needs literature, was developed and applied to 54 radiotherapy information resources. The framework comprised 12 broad themes; cancer diagnosis, general information about radiotherapy, treatment planning, daily treatment, side effects, self-care management, external radiotherapy, internal radiotherapy, impact on daily activities, post-treatment, psychosocial health and other content, such as a glossary. Materials produced by cancer organisations contained significantly more information than hospital resources on diagnosis, general radiotherapy information, internal radiotherapy and psychosocial health. However, hospital materials provided more information about treatment planning, daily treatment and the impact on daily activities. Compared to generic materials, tumour-specific resources were superior in providing information about diagnosis, daily treatment, side effects, post-treatment and psychosocial health. Information about internal radiotherapy, prognosis and chronic side effects were poorly covered by most resources. Collectively, hospital and cancer organisation resources complement each other in meeting patients' information needs. Identifying ways to consolidate different information sources could help comprehensively address patients' medical and psychosocial information needs about radiotherapy. © 2015 John Wiley & Sons Ltd.
Genome-wide transcription responses to synchrotron microbeam radiotherapy.
Sprung, Carl N; Yang, Yuqing; Forrester, Helen B; Li, Jason; Zaitseva, Marina; Cann, Leonie; Restall, Tina; Anderson, Robin L; Crosbie, Jeffrey C; Rogers, Peter A W
2012-10-01
The majority of cancer patients achieve benefit from radiotherapy. A significant limitation of radiotherapy is its relatively low therapeutic index, defined as the maximum radiation dose that causes acceptable normal tissue damage to the minimum dose required to achieve tumor control. Recently, a new radiotherapy modality using synchrotron-generated X-ray microbeam radiotherapy has been demonstrated in animal models to ablate tumors with concurrent sparing of normal tissue. Very little work has been undertaken into the cellular and molecular mechanisms that differentiate microbeam radiotherapy from broad beam. The purpose of this study was to investigate and compare the whole genome transcriptional response of in vivo microbeam radiotherapy versus broad beam irradiated tumors. We hypothesized that gene expression changes after microbeam radiotherapy are different from those seen after broad beam. We found that in EMT6.5 tumors at 4-48 h postirradiation, microbeam radiotherapy differentially regulates a number of genes, including major histocompatibility complex (MHC) class II antigen gene family members, and other immunity-related genes including Ciita, Ifng, Cxcl1, Cxcl9, Indo and Ubd when compared to broad beam. Our findings demonstrate molecular differences in the tumor response to microbeam versus broad beam irradiation and these differences provide insight into the underlying mechanisms of microbeam radiotherapy and broad beam.
Ma, Jin-lu; Jin, Long; Li, Yao-Dong; He, Chen-chen; Guo, Xi-jing; Liu, Rui; Yang, Yun-Yi; Han, Su-xia
2014-01-01
Radiation therapy is one of the standard therapeutic modalities for esophageal cancer, achieving its main antitumor efficacy through DNA damage. However, accumulating evidence shows that radiotherapy can substantially alter the tumor microenvironment, particularly with respect to its effects on immune cells. We hypothesized that the immune response elicited by radiotherapy may be as important as the radiation itself for successful treatment. More specifically, immunomodulatory cytokines may enhance the effectiveness of radiotherapy. To investigate this hypothesis, we measured changes in the serum interferon-gamma (IFN- γ ) and interleukin-2 (IL-2) concentrations during radiotherapy and compared these modifications with outcomes. We found that serum concentrations of IL-2 and IFN- γ were positively associated with local response to radiotherapy in esophageal cancer. More generally, the intensity of the radiotherapy-elicited immune response was positively associated with local response to radiotherapy in esophageal cancer. Changes in serum IL-2 and IFN- γ concentrations were further associated with increased risks of acute hematologic toxicity and acute organ toxicity of the esophagus, lung, and skin. These results suggest that deciphering the mechanisms of radiotherapy-elicited immune response may help in the development of therapeutic interventions that would enhance the efficacy of radiotherapy and convert some ineffective responses to effective responses.
Increased skin and mucosal toxicity in the combination of vemurafenib with radiation therapy.
Merten, Ricarda; Hecht, Markus; Haderlein, Marlen; Distel, Luitpold; Fietkau, Rainer; Heinzerling, Lucie; Semrau, Sabine
2014-11-01
Palliative radiotherapy is often required for patients with metastatic malignant melanoma in the case of bone or brain metastases. Since BRAF inhibitor therapy is highly efficient in V600-mutated melanomas, there is hesitation to stop it during radiotherapy. Consequently, radiotherapy under simultaneous vemurafenib treatment is frequently needed. We report the case of a patient receiving palliative radiotherapy of spinal bone metastases before and during vemurafenib therapy. The skin reactions were quantitatively scored using computer-assisted digital image evaluation. Radiotherapy without vemurafenib was tolerated very well, whereas radiotherapy under simultaneous vemurafenib treatment resulted in accentuated skin reactions. Furthermore, the patient developed dysphagia and had to be hospitalized for parenteral nutrition. In the quantitative analysis, there was a twofold increase in pigmentation and erythema of the irradiated skin area of the thoracic spine when vemurafenib was combined with radiotherapy compared with radiotherapy treatment alone. This is the first reported case of a patient showing no complications during radiotherapy without vemurafenib but remarkable skin and mucosal toxicity under concurrent vemurafenib therapy. Thus, a genetically conditioned individually elevated radiosensitivity can definitely be excluded. Compared with other reported cases, radiosensitization was not limited to the skin, but also affected the esophageal mucosa. Vemurafenib is a strong radiosensitizer. Patients receiving radiotherapy under simultaneous vemurafenib treatment should be monitored very closely.
Temporal Stability of Music Perception and Appraisal Scores of Adult Cochlear Implant Recipients
Gfeller, Kate; Jiang, Dingfeng; Oleson, Jacob; Driscoll, Virginia; Knutson, John F.
2010-01-01
Background An extensive body of literature indicates that cochlear implants are effective in supporting speech perception of persons with severe to profound hearing losses who do not benefit to any great extent from conventional hearing aids. Adult CI recipients tend to show significant improvement in speech perception within 3 months following implantation as a result of mere experience. Furthermore, CI recipients continue to show modest improvement as long as 5 years post implantation. In contrast, data taken from single testing protocols of music perception and appraisal indicate that CIs are less than ideal in transmitting important structural features of music, such as pitch, melody and timbre. However, there is presently little information documenting changes in music perception or appraisal over extended time as a result of mere experience. Purpose This study examined two basic questions: 1) Do adult CI recipients show significant improvement in perceptual acuity or appraisal of specific music listening tasks when tested in two consecutive years? 2) If there are tasks for which CI recipients show significant improvement with time, are there particular demographic variables that predict those CI recipients most likely to show improvement with extended CI use? Research Design A longitudinal cohort study. Implant recipients return annually for visits to the clinic. Study Sample The study included 209 adult cochlear implant recipients with at least 9 months implant experience before their first year measurement. Data collection and analysis Outcomes were measured on the patient’s annual visit in two consecutive years. Paired t-tests were used to test for significant improvement from one year to the next. Those variables demonstrating significant improvement were subjected to regression analyses performed to detect the demographic variables useful in predicting said improvement. Results There were no significant differences in music perception outcomes as a function of type of device or processing strategy used. Only familiar melody recognition (FMR) and recognition of melody excerpts with lyrics (MERT-L) showed significant improvement from one year to the next. After controlling for the baseline value, hearing aid use, months of use, music listening habits after implantation and formal musical training in elementary school were significant predictors of FMR improvement. Bilateral CI use, formal musical training in high school and beyond, and a measure of sequential cognitive processing were significant predictors of MERT-L improvement. Conclusions These adult CI recipients as a result of mere experience demonstrated fairly consistent music perception and appraisal on measures gathered in two consecutive years. Gains made tend to be modest, and can be associated with characteristics such as use of hearing aids, listening experiences, or bilateral use (in the case of lyrics). These results have implications for counseling of CI recipients with regard to realistic expectations and strategies for enhancing music perception and enjoyment. PMID:20085197
Smith, Benjamin D; Smith, Grace L; Roberts, Kenneth B; Buchholz, Thomas A
2009-08-01
In 2007, Medicare implemented the Physician Quality Reporting Initiative (PQRI), which provides financial incentives to physicians who report their performance on certain quality measures. PQRI measure #74 recommends radiotherapy for patients treated with conservative surgery (CS) for invasive breast cancer. As a first step in evaluating the potential impact of this measure, we assessed baseline use of radiotherapy among women diagnosed with invasive breast cancer before implementation of PQRI. Using the SEER-Medicare data set, we identified women aged 66-70 diagnosed with invasive breast cancer and treated with CS between 2000 and 2002. Treatment with radiotherapy was determined using SEER and claims data. Multivariate logistic regression tested whether receipt of radiotherapy varied significantly across clinical, pathologic, and treatment covariates. Of 3,674 patients, 94% (3,445) received radiotherapy. In adjusted analysis, the presence of comorbid illness (odds ratio [OR] 1.69; 95% confidence interval [CI], 1.19-2.42) and unmarried marital status were associated with omission of radiotherapy (OR 1.65; 95% CI, 1.22-2.20). In contrast, receipt of chemotherapy was protective against omission of radiotherapy (OR 0.25; 95% CI, 0.16-0.38). Race and geographic region did not correlate with radiotherapy utilization. Utilization of radiotherapy following CS was high for patients treated before institution of PQRI, suggesting that at most 6% of patients could benefit from measure #74. Further research is needed to determine whether institution of PQRI will affect radiotherapy utilization.
Role of radiotherapy fractionation in head and neck cancers (MARCH): an updated meta-analysis
Lacas, Benjamin; Bourhis, Jean; Overgaard, Jens; Zhang, Qiang; Gregoire, Vincent; Nankivell, Matthew; Zackrisson, Bjorn; Szutkowski, Zbigniew; Suwiński, Rafał; Poulsen, Michael; O’Sullivan, Brian; Corvo, Renzo; Laskar, Sarbani Ghosh; Fallai, Carlo; Yamazaki, Hideya; Dobrowsky, Werner; Cho, Kwan Ho; Garden, Adam S; Langendijk, Johannes A; Viegas, Celia Maria Pais; Hay, John; Lotayef, Mohamed; Parmar, Mahesh K B; Auperin, Anne; van Herpen, Carla; Maingon, Philippe; Trotti, Andy M; Grau, Cai; Pignon, Jean-Pierre; Blanchard, Pierre
2017-01-01
Summary Background The Meta-Analysis of Radiotherapy in squamous cell Carcinomas of Head and neck (MARCH) showed that altered fractionation radiotherapy is associated with improved overall and progression-free survival compared with conventional radiotherapy, with hyperfractionated radiotherapy showing the greatest benefit. This update aims to confirm and explain the superiority of hyperfractionated radiotherapy over other altered fractionation radiotherapy regimens and to assess the benefit of altered fractionation within the context of concomitant chemotherapy with the inclusion of new trials. Methods For this updated meta-analysis, we searched bibliography databases, trials registries, and meeting proceedings for published or unpublished randomised trials done between Jan 1, 2009, and July 15, 2015, comparing primary or postoperative conventional fractionation radiotherapy versus altered fractionation radiotherapy (comparison 1) or conventional fractionation radiotherapy plus concomitant chemotherapy versus altered fractionation radiotherapy alone (comparison 2). Eligible trials had to start randomisation on or after Jan 1, 1970, and completed accrual before Dec 31, 2010; had to have been randomised in a way that precluded prior knowledge of treatment assignment; and had to include patients with non-metastatic squamous cell carcinoma of the oral cavity, oropharynx, hypopharynx, or larynx undergoing first-line curative treatment. Trials including a non-conventional radiotherapy control group, investigating hypofractionated radiotherapy, or including mostly nasopharyngeal carcinomas were excluded. Trials were grouped in three types of altered fractionation: hyperfractionated, moderately accelerated, and very accelerated. Individual patient data were collected and combined with a fixed-effects model based on the intention-to-treat principle. The primary endpoint was overall survival. Findings Comparison 1 (conventional fractionation radiotherapy vs altered fractionation radiotherapy) included 33 trials and 11 423 patients. Altered fractionation radiotherapy was associated with a significant benefit on overall survival (hazard ratio [HR] 0·94, 95% CI 0·90–0·98; p=0·0033), with an absolute difference at 5 years of 3·1% (95% CI 1·3–4·9) and at 10 years of 1·2% (−0·8 to 3·2). We found a significant interaction (p=0·051) between type of fractionation and treatment effect, the overall survival benefit being restricted to the hyperfractionated group (HR 0·83, 0·74–0·92), with absolute differences at 5 years of 8·1% (3·4 to 12·8) and at 10 years of 3·9% (−0·6 to 8·4). Comparison 2 (conventional fractionation radiotherapy plus concomitant chemotherapy versus altered fractionation radiotherapy alone) included five trials and 986 patients. Overall survival was significantly worse with altered fractionation radiotherapy compared with concomitant chemoradiotherapy (HR 1·22, 1·05–1·42; p=0·0098), with absolute differences at 5 years of −5·8% (−11·9 to 0·3) and at 10 years of −5·1% (−13·0 to 2·8). Interpretation This update confirms, with more patients and a longer follow-up than the first version of MARCH, that hyperfractionated radiotherapy is, along with concomitant chemoradiotherapy, a standard of care for the treatment of locally advanced head and neck squamous cell cancers. The comparison between hyperfractionated radiotherapy and concomitant chemoradiotherapy remains to be specifically tested. PMID:28757375
Trend in and Correlates of Undergoing Radiotherapy in Taiwanese Cancer Patients' Last Month of Life.
Hung, Yen-Ni; Cheng, Skye Hung-Chun; Liu, Tsang-Wu; Chang, Wen-Cheng; Chen, Jen-Shi; Tang, Siew Tzuh
2016-09-01
A significant proportion of cancer patients at end of life (EOL) undergo radiotherapy, but this evidence is not from nationwide population-based studies. The aims of this population-based study were to investigate the trend in undergoing radiotherapy among Taiwanese cancer patients' last month of life (EOL radiotherapy) in 2001-2010 and to identify factors associated with EOL radiotherapy. This was a population-based retrospective cohort study analyzing data from Taiwan's national death registry, cancer registry, and National Health Insurance claims for EOL radiotherapy using multilevel generalized linear mixed modeling. Participants were Taiwanese cancer patients (N = 339,546) who died in 2001-2010. Overall, 8.59% (7.97%-9.85%) of patients underwent EOL radiotherapy with a decreasing trend over time. Correlates of EOL radiotherapy included male gender, younger age, residing in less urbanized areas, diagnosis of lung cancer, metastatic disease, death within two years of diagnosis, and without comorbidities. Cancer patients were more likely to undergo EOL radiotherapy if they received primary care from medical oncologists and pediatricians, in a nonprofit, teaching hospital with a larger case volume of terminally ill cancer patients, and greater EOL care intensity. Approximately one-tenth of Taiwanese cancer patients underwent EOL radiotherapy with a decreasing trend over time. Undergoing EOL radiotherapy was associated with demographics, disease characteristics, physician specialty, and primary hospital's characteristics and EOL care practice patterns. Clinical and financial interventions should target hospitals/physicians that tend to aggressively treat at-risk cancer patients at EOL to carefully evaluate the appropriateness and effectiveness of using EOL radiotherapy. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Ryken, Timothy C; Parney, Ian; Buatti, John; Kalkanis, Steven N; Olson, Jeffrey J
2015-12-01
(1) What is the optimal role of external beam radiotherapy in the management of adult patients with newly diagnosed low-grade glioma (LGG) in terms of improving outcome (i.e., survival, complications, seizure control or other reported outcomes of interest)? (2) Which radiation strategies (dose, timing, fractionation, stereotactic radiation, brachytherapy, chemotherapy) improve outcomes compared to standard external beam radiation therapy in the initial management of low grade gliomas in adults? (3) Do specific factors (e.g., age, volume, extent of resection, genetic subtype) identify subgroups with better outcomes following radiation therapy than the general population of adults with newly diagnosed low-grade gliomas? These recommendations apply to adults with newly diagnosed diffuse LGG. OUTCOMES IN ADULT PATIENTS WITH NEWLY DIAGNOSED LOW GRADE GLIOMA TREATED WITH RADIOTHERAPY: Level I Radiotherapy is recommended in the management of newly diagnosed low-grade glioma in adults to prolong progression free survival, irrespective of extent of resection. Level II Radiotherapy is recommended in the management of newly diagnosed low grade glioma in adults as an equivalent alternative to observation in preserving cognitive function, irrespective of extent of resection. Level III Radiotherapy is recommended in the management of newly diagnosed low grade glioma in adults to improve seizure control in patients with epilepsy and subtotal resection. Level III Radiotherapy is recommended in the management of newly diagnosed low-grade glioma in adults to prolong overall survival in patients with subtotal resection. Level III Consideration of the risk of radiation induced morbidity, including cognitive decline, imaging abnormalities, metabolic dysfunction and malignant transformation, is recommended when the delivery of radiotherapy is selected in the management of newly diagnosed low-grade glioma in adults. STRATEGIES OF RADIOTHERAPY IN ADULT PATIENTS WITH NEWLY DIAGNOSED LOW GRADE GLIOMA: Level I Lower dose radiotherapy is recommended as an equivalent alternative to higher dose immediate postoperative radiotherapy (45-50.4 vs. 59.4-64.8 Gy) in the management of newly diagnosed low-grade glioma in adults with reduced toxicity. Level III Delaying radiotherapy until recurrence or progression is recommended as an equivalent alternative to immediate postoperative radiotherapy in the management of newly diagnosed low-grade glioma in adults but may result in shorter time to progression. Level III The addition of chemotherapy to radiotherapy is not recommended over whole brain radiotherapy alone in the management of low-grade glioma, as it provides no additional survival benefit. Level III Limited-field radiotherapy is recommended over whole brain radiotherapy in the management of low-grade glioma. Level III Either stereotactic radiosurgery or brachytherapy are recommended as acceptable alternatives to external radiotherapy in selected patients. PROGNOSTIC FACTORS IN ADULT PATIENTS WITH NEWLY DIAGNOSED LOW GRADE GLIOMA TREATED WITH RADIOTHERAPY: Level II It is recommended that age greater than 40 years, astrocytic pathology, diameter greater than 6 cm, tumor crossing the midline and preoperative neurological deficit be considered as negative prognostic indicators when predicting overall survival in adult low grade glioma patients treated with radiotherapy. Level II It is recommended that smaller tumor size, extent of surgical resection and higher mini-mental status exam be considered as positive prognostic indicators when predicting overall survival and progression free survival in patients in adult low grade glioma patients treated with radiotherapy. Level III It is recommended that seizures at presentation, presence of oligodendroglial histological component and 1p19q deletion (along with additional relevant factors-see Table 1) be considered as positive prognostic indicators when predicting response to radiotherapy in adults with low grade gliomas. Level III It is recommended that increasing age, decreasing performance status, decreasing cognition, presence of astrocytic histological component (along with additional relevant factors (see Tables 1, 2) be considered as negative prognostic indicators when predicting response to radiotherapy.
Radiotherapy of rectal cancer in elderly patients: Real-world data assessment in a decade.
Diao, Peng; Langrand-Escure, Julien; Garcia, Max-Adrien; Espenel, Sophie; Rehailia-Blanchard, Amel; de Lavigerie, Blandine; Vial, Nicolas; de Laroche, Guy; Vallard, Alexis; Magné, Nicolas
2018-06-01
There is paucity of data on the efficacy and toxicity of radiotherapy in rectal cancer (RC) elderly patients. The objective was to identify management strategies and resulting outcomes in RC patients ≥70 years undergoing radiotherapy. A retrospective study included consecutive RC patients ≥70 years undergoing rectal radiotherapy. From 2004-2015, 340 RC patients underwent pre-operative (n = 238; 70%), post-operative (n = 41, 12%), or exclusive (n = 61, 18%) radiotherapy, with a median age of 78.5 years old (range: 70-96). Radiotherapy protocols were tailored, with 54 different radiotherapy programs (alteration of the total dose, and/or fractionation, and/or volume). Median follow-up was 27.1 months. Acute and late grade 3-4 radio-induced toxicities were reported in 3.5% and 0.9% of patients. Metastatic setting (OR = 6.60, CI95% 1.47-46.03, p = 0.02), exclusive radiotherapy (OR = 5.08, CI95% 1.48-18.21, p = 0.009), and intensity-modulated radiotherapy (OR = 6.42, CI95% 1.31-24.73, p = 0.01) were associated with grade ≥3 acute toxicities in univariate analysis. Exclusive radiotherapy (OR = 9.79, CI95% 2.49-43.18, p = 0.001) and intensity-modulated radiotherapy (OR = 12.62, CI95% 2.05-71.26, p = 0.003) were independent predictive factors of grade ≥3 acute toxicities in multivariate analysis. A complete pathological response was achieved in 12 out of 221 pre-operative patients (5.4%). Age, tumor stage, and surgery were independent predictive factors of survival in multivariate analysis. At end of follow-up, 7.1% of patients experienced local relapse. Radiotherapy for RC in elderly patients appeared safe and manageable, perhaps due to the tailoring of radiotherapy protocols. Tailored management resulted in acceptable rate of local tumor control. Copyright © 2018 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Oral mucosal melanoma treated with carbon ion radiotherapy: a case report.
Musha, Atsushi; Saitoh, Jun-Ichi; Shirai, Katsuyuki; Yokoo, Satoshi; Ohno, Tatsuya; Nakano, Takashi
2016-10-18
Oral mucosal melanoma is a rare disease with a relatively poor prognosis. Carbon ion radiotherapy has been shown to be effective against radiotherapy-resistant tumors owing to its excellent dose concentration and high biological effect. Our patient was a 66-year-old Japanese man with oral mucosal melanoma of his right maxillary gingiva (T4aN0M0). He received carbon ion radiotherapy at 57.6 Gy (relative biological effectiveness) in 16 fractions for 4 weeks. Concomitant chemotherapy (dacarbazine + nimustine + vincristine) was administered at the same time as carbon ion radiotherapy initiation. Two courses of adjuvant chemotherapy were given after carbon ion radiotherapy. Although he experienced grade 2 acute oral mucositis, his symptoms improved within a few weeks of undergoing carbon ion radiotherapy. He was alive at the time of reporting, 35 months after treatment, without any recurrence. Late toxicity has not been observed. Carbon ion radiotherapy for oral mucosal melanoma resulted in a good local effect.
Lung Cancer: Posttreatment Imaging: Radiation Therapy and Imaging Findings.
Benveniste, Marcelo F; Welsh, James; Viswanathan, Chitra; Shroff, Girish S; Betancourt Cuellar, Sonia L; Carter, Brett W; Marom, Edith M
2018-05-01
In this review, we discuss the different radiation delivery techniques available to treat non-small cell lung cancer, typical radiologic manifestations of conventional radiotherapy, and different patterns of lung injury and temporal evolution of the newer radiotherapy techniques. More sophisticated techniques include intensity-modulated radiotherapy, stereotactic body radiotherapy, proton therapy, and respiration-correlated computed tomography or 4-dimensional computed tomography for radiotherapy planning. Knowledge of the radiation treatment plan and technique, the completion date of radiotherapy, and the temporal evolution of radiation-induced lung injury is important to identify expected manifestations of radiation-induced lung injury and differentiate them from tumor recurrence or infection. Published by Elsevier Inc.
Recent Advances in Image-Guided Radiotherapy for Head and Neck Carcinoma
Nath, Sameer K.; Simpson, Daniel R.; Rose, Brent S.; Sandhu, Ajay P.
2009-01-01
Radiotherapy has a well-established role in the management of head and neck cancers. Over the past decade, a variety of new imaging modalities have been incorporated into the radiotherapy planning and delivery process. These technologies are collectively referred to as image-guided radiotherapy and may lead to significant gains in tumor control and radiation side effect profiles. In the following review, these techniques as they are applied to head and neck cancer patients are described, and clinical studies analyzing their use in target delineation, patient positioning, and adaptive radiotherapy are highlighted. Finally, we conclude with a brief discussion of potential areas of further radiotherapy advancement. PMID:19644564
Preece, David; Allan, Alfred; Becerra, Rodrigo
2016-01-01
To examine the neuropsychological outcomes for an adult patient, 2 years after receiving microsurgery and conventional radiotherapy for a recurrent craniopharyngioma; and the impact of a further intervention, stereotactic radiotherapy, on this level of neuropsychological functioning. JD, a 30 year old male whose recurrent craniopharyngioma had 2 years earlier been treated with two operations and conventional radiotherapy. JD was assessed (using standardized clinical tests) before and after a course of stereotactic radiotherapy. Prior to stereotactic radiotherapy (and 2 years after microsurgery and conventional radiotherapy) JD's IQ was intact, but considerable impairments were present in executive functioning, memory, theory of mind and processing speed. Fifteen months after stereotactic radiotherapy, all neuropsychological domains remained largely static or improved, supporting the utility of this treatment option in the neuropsychological domain. However, deficits in executive functioning, memory and processing speed remained. These findings suggest that, even after multiple treatments, substantial cognitive impairments can be present in an adult patient with a recurrent craniopharyngioma. This profile of deficits underlines the inadequacy of relying purely on IQ as a marker for cognitive health in this population and emphasizes the need to include neuropsychological impairments as a focus of rehabilitation with these patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sponseller, Patricia, E-mail: sponselp@uw.edu; Department of Radiation Oncology, University of Washington Medical Center, Seattle, WA; Paravathaneni, Upendra
2013-07-01
The purpose of this report is to communicate a technique to match an electron field to the dose distribution of an Intensity-Modulated Radiation Therapy (IMRT) plan. A patient with multiple areas of squamous cell carcinoma over the scalp was treated using 60 Gy in 2.0-Gy fractions to the entire scalp and first echelon nodes with multiple 6-MV photon fields. To deliver an adequate dose to the scalp, a custom 1.0-cm bolus helmet was fashioned using a solid piece of aquaplast. Along with the IMRT scalp treatment, a left zygoma area was treated with electrons matching the anterior border of themore » IMRT dose distribution. The border was matched by creating a left lateral field with the multileaf collimator shaped to the IMRT dose distribution. The result indicated an adequate dose to the skin match between the IMRT plan and the electron field. Results were confirmed using optically stimulated luminescence placed at the skin match area, so that the dose matched the prescription within 10%.« less
1999-08-01
of 11ln-DTPA-hEGF in a compartment and a rate of elimination corresponding to the radioactive decay of the radionuclide, indium-1Il. = A0 /A, where I...on the growth rate of MDA-MB-468 or MCF-7 (1.5 X 104 EGFR/cell) cells was determined following treatment in vitro with 11 In-DTPA- hEGF, unlabelled...the nucleus within 24 hours. Chromatin contained 10% of internalized radioactivity. The growth rate of MDA-MB-468 cells was decreased 3-fold by
Feasibility of dual-energy computed tomography in radiation therapy planning
NASA Astrophysics Data System (ADS)
Sheen, Heesoon; Shin, Han-Back; Cho, Sungkoo; Cho, Junsang; Han, Youngyih
2017-12-01
In this study, the noise level, effective atomic number ( Z eff), accuracy of the computed tomography (CT) number, and the CT number to the relative electron density EDconversion curve were estimated for virtual monochromatic energy and polychromatic energy. These values were compared to the theoretically predicted values to investigate the feasibility of the use of dual-energy CT in routine radiation therapy planning. The accuracies of the parameters were within the range of acceptability. These results can serve as a stepping stone toward the routine use of dual-energy CT in radiotherapy planning.
Heuser, Michael; Samiei, Massoud; Shah, Ragesh; Lutters, Gerd; Bodis, Stephan
2015-01-01
Abstract Globally, new cancer cases will rise by 57% within the next two decades, with the majority in the low- and middle-income countries (LMICs). Consequently, a steep increase of about 40% in cancer deaths is expected there, mainly because of lack of treatment facilities, especially radiotherapy. Radiotherapy is required for more than 50% of patients, but the capital cost for equipment often deters establishment of such facilities in LMICs. Presently, of the 139 LMICs, 55 do not even have a radiotherapy facility, whereas the remaining 84 have a deficit of 61.4% of their required radiotherapy units. Networking between centers could enhance the effectiveness and reach of existing radiotherapy in LMICs. A teleradiotherapy network could enable centers to share and optimally utilize their resources, both infrastructure and staffing. This could be in the form of a three-tier radiotherapy service consisting of primary, secondary, and tertiary radiotherapy centers interlinked through a network. The concept has been adopted in some LMICs and could also be used as a “service provider model,” thereby reducing the investments to set up such a network. Teleradiotherapy networks could be a part of the multipronged approach to address the enormous gap in radiotherapy services in a cost-effective manner and to support better accessibility to radiotherapy facilities, especially for LMICs. PMID:25763906
Marangoni-Lopes, L; Rodrigues, L P; Mendonça, R H; Nobre-Dos Santos, M
2016-12-01
We aimed to perform a longitudinal investigation of the effects of radiotherapy on salivary flow rate, pH, buffering capacity, and protein composition of saliva and on the quality of life of children with Hodgkin disease. Ten children (6-16-year-old) with Hodgkin disease and 10 matched healthy children were investigated. Stimulated and non-stimulated saliva samples were collected at baseline, after 1080 and 2160cGy of radiation, and 1, 2, and 3 months post-radiotherapy. The salivary flow rate was expressed as mL/min. Buffer capacity was determined by titration. Amylase activity, immunoglobulin A, mucin, and lactoferrin concentrations were determined by ELISA. Quality of life was assessed by Quality of Life - Head and Neck module 35 questionnaire. We found that radiotherapy caused hyposalivation at 1080cGy and 1 month after radiotherapy and reduced buffering capacity at 2160cGy. Mucin concentration and amylase activity in non-stimulated saliva increased 1 month after radiotherapy. Lactoferrin concentration increased during and after radiotherapy. Immunoglobulin A concentration increased at 1080cGy, 1 and 2 months, for non-stimulated saliva and at 2160cGy and 1 month for stimulated saliva. Children reported more pain after radiotherapy and more xerostomia during radiotherapy. We concluded that the radiotherapy protocol affected the children's salivary properties and children's quality of life. Copyright © 2016 Elsevier Ltd. All rights reserved.
The med AUSTRON/OGRO patterns of care study on radiotherapy indications in Austria.
Mock, Ulrike; Mayer, Ramona; Potter, Richard; Jäger, Robert; Vutuc, Christian; Eiter, Helmut; Hammer, Josef; Hawliczek, Robert; Hirn, Brigitte; Knocke-Abulesz, Tomas-Henrik; Kogelnik, Hans-Dieter; Lukas, Peter; Nechville, Elisabeth; Pakisch, Brigitte; Papauschek, Michael; Ing Raunik, Wolfgang; Rhomberg, Walter; Sabitzer, Hubert; Schratter-Sehn, Annemarie; Sedlmayer, Felix; Wedrich, Irene; Auberger, Thomas
2004-12-01
In Austria a national survey was conducted by Med AUSTRON/Osterreichische Gesellschaft for Radio--Onkologie, Radiobiologie und Medizinische Radiophysik (OGRO) in order to estimate the indications, patient numbers and radiotherapy treatment planning procedures and performances at all Austrian radiotherapy institutes. Results were correlated with incidence rates (Austrian cancer registry) to determine patterns of radiotherapy practice in Austria. At 12 radiotherapy departments of Austria data of all patients receiving irradiation within a 3 months (2002/2003) period were assessed. On the basis of a questionnaire number of treated patients, indications, and parameters of disease (stage, histology) and treatment modalities were evaluated. Results were analysed with regard to different tumour groups, according to academic and non academic hospitals, and correlated with epidemiological data on cancer incidence. In total, 3783 patients were registered within this period. According to the different tumour entities percentages of patients receiving radiotherapy within initial treatment varied from 3% to 90 % (e.g. brain tumours: 77%, breast cancer: 90%, prostate cancer: 35%). The most frequent indications to radiotherapy per radiotherapy department were breast cancer (range 22%-35%; mean 26%), urological tumours (range 6%-27%; mean 12%) and bone metastases (mean 10%, range 3%-17%). In Austria breast cancer, urological tumours and bone metastases are representing the most common indications to radiotherapy. Among the different departments variations in indications to radiotherapy were observed. Our study is the first evaluation of radiotherapeutic management in Austria.
Datta, Niloy Ranjan; Heuser, Michael; Samiei, Massoud; Shah, Ragesh; Lutters, Gerd; Bodis, Stephan
2015-07-01
Globally, new cancer cases will rise by 57% within the next two decades, with the majority in the low- and middle-income countries (LMICs). Consequently, a steep increase of about 40% in cancer deaths is expected there, mainly because of lack of treatment facilities, especially radiotherapy. Radiotherapy is required for more than 50% of patients, but the capital cost for equipment often deters establishment of such facilities in LMICs. Presently, of the 139 LMICs, 55 do not even have a radiotherapy facility, whereas the remaining 84 have a deficit of 61.4% of their required radiotherapy units. Networking between centers could enhance the effectiveness and reach of existing radiotherapy in LMICs. A teleradiotherapy network could enable centers to share and optimally utilize their resources, both infrastructure and staffing. This could be in the form of a three-tier radiotherapy service consisting of primary, secondary, and tertiary radiotherapy centers interlinked through a network. The concept has been adopted in some LMICs and could also be used as a "service provider model," thereby reducing the investments to set up such a network. Teleradiotherapy networks could be a part of the multipronged approach to address the enormous gap in radiotherapy services in a cost-effective manner and to support better accessibility to radiotherapy facilities, especially for LMICs.
Surace, Laura; Lysenko, Veronika; Fontana, Andrea Orlando; Cecconi, Virginia; Janssen, Hans; Bicvic, Antonela; Okoniewski, Michal; Pruschy, Martin; Dummer, Reinhard; Neefjes, Jacques; Knuth, Alexander; Gupta, Anurag; van den Broek, Maries
2015-04-21
Radiotherapy induces DNA damage and cell death, but recent data suggest that concomitant immune stimulation is an integral part of the therapeutic action of ionizing radiation. It is poorly understood how radiotherapy supports tumor-specific immunity. Here we report that radiotherapy induced tumor cell death and transiently activated complement both in murine and human tumors. The local production of pro-inflammatory anaphylatoxins C3a and C5a was crucial to the tumor response to radiotherapy and concomitant stimulation of tumor-specific immunity. Dexamethasone, a drug frequently given during radiotherapy, limited complement activation and the anti-tumor effects of the immune system. Overall, our findings indicate that anaphylatoxins are key players in radiotherapy-induced tumor-specific immunity and the ensuing clinical responses. Copyright © 2015 Elsevier Inc. All rights reserved.
Caminero Cueva, Maria Jesús; Señaris González, Blanca; Llorente Pendás, José Luis; Gorriz Gil, Carmen; López Llames, Aurora; Alonso Pantiga, Ramón; Suárez Nieto, Carlos
2007-01-01
We analyzed the functional outcome and self-evaluation of the voice of patients with T1 glottic carcinoma treated with endoscopic laser surgery and radiotherapy. We performed an objective voice evaluation, as well as a physical, emotional and functional well being assessment of 19 patients treated with laser surgery and 18 patients treated with radiotherapy. Voice quality is affected both by surgery and radiotherapy. Voice parameters only show differences in the maximum phonation time between both treatments. Results in the Voice Handicap Index show that radiotherapy has less effect on patient voice quality perception. There is a reduced impact on the patient’s perception of voice quality after radiotherapy, despite there being no significant differences in vocal quality between radiotherapy and laser cordectomy. PMID:17999074
Adaptive Radiation for Lung Cancer
Gomez, Daniel R.; Chang, Joe Y.
2011-01-01
The challenges of lung cancer radiotherapy are intra/inter-fraction tumor/organ anatomy/motion changes and the need to spare surrounding critical structures. Evolving radiotherapy technologies, such as four-dimensional (4D) image-based motion management, daily on-board imaging and adaptive radiotherapy based on volumetric images over the course of radiotherapy, have enabled us to deliver higher dose to target while minimizing normal tissue toxicities. The image-guided radiotherapy adapted to changes of motion and anatomy has made the radiotherapy more precise and allowed ablative dose delivered to the target using novel treatment approaches such as intensity-modulated radiation therapy, stereotactic body radiation therapy, and proton therapy in lung cancer, techniques used to be considered very sensitive to motion change. Future clinical trials using real time tracking and biological adaptive radiotherapy based on functional images are proposed. PMID:20814539
Reirradiation for recurrent head and neck cancers using charged particle or photon radiotherapy.
Yamazaki, Hideya; Demizu, Yusuke; Okimoto, Tomoaki; Ogita, Mikio; Himei, Kengo; Nakamura, Satoaki; Suzuki, Gen; Yoshida, Ken; Kotsuma, Tadayuki; Yoshioka, Yasuo; Oh, Ryoongjin
2017-07-01
To examine the outcomes of reirradiation for recurrent head and neck cancers using different modalities. This retrospective study included 26 patients who received charged particle radiotherapy (CP) and 150 who received photon radiotherapy (117 CyberKnife radiotherapy [CK] and 36 intensity-modulated radiotherapy [IMRT]). Inverse probability of treatment weighting (IPTW) involving propensity scores was used to reduce background selection bias. Higher prescribed doses were used in CP than photon radiotherapy. The 1‑year overall survival (OS) rates were 67.9% for CP and 54.1% for photon radiotherapy (p = 0.15; 55% for CK and 51% for IMRT). In multivariate Cox regression, the significant prognostic factors for better survival were nasopharyngeal cancer, higher prescribed dose, and lower tumor volume. IPTW showed a statistically significant difference between CP and photon radiotherapy (p = 0.04). The local control rates for patients treated with CP and photon radiotherapy at 1 year were 66.9% (range 46.3-87.5%) and 67.1% (range 58.3-75.9%), respectively. A total of 48 patients (27%) experienced toxicity grade ≥3 (24% in the photon radiotherapy group and 46% in the CP group), including 17 patients with grade 5 toxicity. Multivariate analysis revealed that younger age and a larger planning target volume (PTV) were significant risk factors for grade 3 or worse toxicity. CP provided superior survival outcome compared to photon radiotherapy. Tumor volume, primary site (nasopharyngeal), and prescribed dose were identified as survival factors. Younger patients with a larger PTV experienced toxicity grade ≥3.
Noh, O Kyu; Lee, Sang-wook; Yoon, Sang Min; Kim, Sung Bae; Kim, Sang Yoon; Kim, Chang Jin; Jo, Kyung Ja; Choi, Eun Kyung; Song, Si Yeol; Kim, Jong Hoon; Ahn, Seung Do
2011-02-01
The role of elective nodal irradiation (ENI) in radiotherapy for esthesioneuroblastoma (ENB) has not been clearly defined. We analyzed treatment outcomes of patients with ENB and the frequency of cervical nodal failure in the absence of ENI. Between August 1996 and December 2007, we consulted with 19 patients with ENB regarding radiotherapy. Initial treatment consisted of surgery alone in 2 patients; surgery and postoperative radiotherapy in 4; surgery and adjuvant chemotherapy in 1; surgery, postoperative radiotherapy, and chemotherapy in 3; and chemotherapy followed by radiotherapy or concurrent chemoradiotherapy in 5. Five patients did not receive planned radiotherapy because of disease progression. Including 2 patients who received salvage radiotherapy, 14 patients were treated with radiotherapy. Elective nodal irradiation was performed in 4 patients with high-risk factors, including 3 with cervical lymph node metastasis at presentation. Fourteen patients were analyzable, with a median follow-up of 27 months (range, 7-64 months). The overall 3-year survival rate was 73.4%. Local failure occurred in 3 patients (21.4%), regional cervical failure in 3 (21.4%), and distant failure in 2 (14.3%). No cervical nodal failure occurred in patients treated with combined systemic chemotherapy regardless of ENI. Three cervical failures occurred in the 4 patients treated with ENI or neck dissection (75%), none of whom received systemic chemotherapy. ENI during radiotherapy for ENB seems to play a limited role in preventing cervical nodal failure. Omitting ENI may be an option if patients are treated with a combination of radiotherapy and chemotherapy. Copyright © 2011 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oborn, B. M., E-mail: brad.oborn@gmail.com; Ge, Y.; Hardcastle, N.
2016-01-15
Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: A total of eight clinical lung tumor cases were recalculated using Monte Carlo methods, and external magnetic fields of 0.5, 1.0, and 3 T were included to observe the impact on dose to the planning target volume (PTV) and gross tumor volume (GTV). Three plans were 6 MV 3D-CRT plans while 6 were 6 MV IMRT. The GTV’s ranged from 0.8 to 16 cm{sup 3}, whilemore » the PTV’s ranged from 1 to 59 cm{sup 3}. In addition, the dose changes in a 30 cm diameter cylindrical water phantom were investigated for small beams. The central 20 cm of this phantom contained either water or lung density insert. Results: For single beams, an inline magnetic field of 1 T has a small impact in lung dose distributions by reducing the lateral scatter of secondary electrons, resulting in a small dose increase along the beam. Superposition of multiple small beams leads to significant dose enhancements. Clinically, this process occurs in the lung tissue typically surrounding the GTV, resulting in increases to the D{sub 98%} (PTV). Two isolated tumors with very small PTVs (3 and 6 cm{sup 3}) showed increases in D{sub 98%} of 23% and 22%. Larger PTVs of 13, 26, and 59 cm{sup 3} had increases of 9%, 6%, and 4%, describing a natural fall-off in enhancement with increasing PTV size. However, three PTVs bounded to the lung wall showed no significant increase, due to lack of dose enhancement in the denser PTV volume. In general, at 0.5 T, the GTV mean dose enhancement is around 60% lower than that at 1 T, while at 3 T, it is 5%–60% higher than 1 T. Conclusions: Monte Carlo methods have described significant and predictable dose enhancement effects in small lung tumor plans for 6 MV radiotherapy when an external inline magnetic field is included. Results of this study indicate that future clinical inline MRI-guided radiotherapy systems will be able to deliver a dosimetrically superior treatment to small (PTV < 15 cm{sup 3}), isolated lung tumors over non-MRI-Linac systems. This increased efficacy coincides with the reimbursement in the United States of lung CT screening and the likely rapid growth in the number of patients with small lung tumors to be treated with radiotherapy.« less
NASA Astrophysics Data System (ADS)
De Saint-Hubert, Marijke; Verellen, Dirk; Poels, Kenneth; Crijns, Wouter; Magliona, Federica; Depuydt, Tom; Vanhavere, Filip; Struelens, Lara
2017-07-01
Medulloblastoma treatment involves irradiation of the entire central nervous system, i.e. craniospinal irradiation (CSI). This is associated with the significant exposure of large volumes of healthy tissue and there is growing concern regarding treatment-associated side effects. The current study compares out-of-field organ doses in children receiving CSI through 3D-conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT), helical tomotherapy (HT) and an electron-based technique, and includes radiation doses resulting from imaging performed during treatment. An extensive phantom study is performed, using an anthropomorphic phantom corresponding to a five year old child, in which organ absorbed doses are measured using thermoluminescent detectors. Additionally, the study evaluates and explores tools for calculating out-of-field patient doses using the treatment planning system (TPS) and analytical models. In our study, 3D-CRT resulted in very high doses to a limited number of organs, while it was able to spare organs such as the lungs and breast when compared to IMRT and HT. Both IMRT and HT spread the dose over more organs and were able to spare the heart, thyroid, bladder, uterus and testes when compared to 3D-CRT. The electron-based technique considerably decreased the out-of-field doses in deep-seated organs but could not avoid nearby out-of-field organs such as the lungs, ribs, adrenals, kidneys and uterus. The daily imaging dose is small compared to the treatment dose burden. The TPS error for out-of-field doses was most pronounced for organs further away from the target; nevertheless, no systematic underestimation was observed for any of the studied TPS systems. Finally, analytical modeling was most optimal for 3D-CRT although the number of organs that could be modeled was limited. To conclude, none of the techniques studied was capable of sparing all organs from out-of-field doses. Nevertheless, the electron-based technique showed the most promise for out-of-field organ dose reduction during CSI when compared to photon techniques.
Sikora, K.
1994-01-01
The use of radiotherapy in treating breast cancer has meant that many women are able to avoid mastectomy, which is both physically and psychologically damaging. The side effects of radiotherapy, however, are given little attention. Many women have developed brachial plexus injury after radiotherapy for breast cancer, often resulting in severe pain and loss of use of the arm. There is no effective treatment for this injury and little help can be offered. In addition, many of the women did not require radiotherapy of nodal areas. A pressure group has been formed to support these women, to establish the right to compensation, and to ensure that radiotherapy regimens given to future patients will not damage the brachial plexus. Images p188-a PMID:8312773
Radiotherapy fiber dosimeter probes based on silver-only coated hollow glass waveguides
NASA Astrophysics Data System (ADS)
Darafsheh, Arash; Melzer, Jeffrey E.; Harrington, James A.; Kassaee, Alireza; Finlay, Jarod C.
2018-01-01
Manifestation of Čerenkov radiation as a contaminating signal is a significant issue in radiation therapy dose measurement by fiber-coupled scintillator dosimeters. To enhance the scintillation signal transmission while minimizing Čerenkov radiation contamination, we designed a fiber probe using a silver-only coated hollow waveguide (HWG). The HWG with scintillator inserted in its tip, embedded in tissue-mimicking phantoms, was irradiated with clinical electron and photon beams generated by a medical linear accelerator. Optical spectra of the irradiated tip were taken using a fiber spectrometer, and the signal was deconvolved with a linear fitting algorithm. The resultant decomposed spectra of the scintillator with and without Čerenkov correction were in agreement with measurements performed by a standard electron diode and ion chamber for electron and photon beam dosimetry, respectively, indicating the minimal effect of Čerenkov contamination in the HWG-based dosimeter. Furthermore, compared with a silver/dielectric-coated HWG fiber dosimeter design, we observed higher signal transmission in the design based on the use of silver-only HWG.
NASA Astrophysics Data System (ADS)
Michaud, M.; Bazin, M.; Sanche, L.
2013-03-01
Radiopharmaceuticals emitting Auger electrons are often injected into patients undergoing cancer treatment with targeted radionuclide therapy (TRT). In this type of radiotherapy, the radiation source is radial and most of the emitted primary particles are low-energy electrons (LEEs) having kinetic energies distributed mostly from zero to a few hundred electron volts with very short ranges in biological media. These LEEs generate a high density of energy deposits and clustered damage, thus offering a relative biological effectiveness comparable to that of alpha particles. In this paper, we present a simple model and corresponding measurements to assess the energy deposited near the site of the radiopharmaceuticals in TRT. As an example, a calculation is performed for the decay of a single 125I radionuclide surrounded by a 1-nm-radius spherical shell of cytosine molecules using the energy spectrum of LEEs emitted by 125I along with their stopping cross sections between 0 and 18 eV. The dose absorbed by the cytosine shell, which occupies a volume of 4 nm3, is extremely high. It amounts to 79 kGy per decay of which 3%, 39%, and 58% is attributed to vibrational excitations, electronic excitations, and ionization processes, respectively.
Sakata, Dousatsu; Kyriakou, Ioanna; Okada, Shogo; Tran, Hoang N; Lampe, Nathanael; Guatelli, Susanna; Bordage, Marie-Claude; Ivanchenko, Vladimir; Murakami, Koichi; Sasaki, Takashi; Emfietzoglou, Dimitris; Incerti, Sebastien
2018-05-01
Gold nanoparticles (GNPs) are known to enhance the absorbed dose in their vicinity following photon-based irradiation. To investigate the therapeutic effectiveness of GNPs, previous Monte Carlo simulation studies have explored GNP dose enhancement using mostly condensed-history models. However, in general, such models are suitable for macroscopic volumes and for electron energies above a few hundred electron volts. We have recently developed, for the Geant4-DNA extension of the Geant4 Monte Carlo simulation toolkit, discrete physics models for electron transport in gold which include the description of the full atomic de-excitation cascade. These models allow event-by-event simulation of electron tracks in gold down to 10 eV. The present work describes how such specialized physics models impact simulation-based studies on GNP-radioenhancement in a context of x-ray radiotherapy. The new discrete physics models are compared to the Geant4 Penelope and Livermore condensed-history models, which are being widely used for simulation-based NP radioenhancement studies. An ad hoc Geant4 simulation application has been developed to calculate the absorbed dose in liquid water around a GNP and its radioenhancement, caused by secondary particles emitted from the GNP itself, when irradiated with a monoenergetic electron beam. The effect of the new physics models is also quantified in the calculation of secondary particle spectra, when originating in the GNP and when exiting from it. The new physics models show similar backscattering coefficients with the existing Geant4 Livermore and Penelope models in large volumes for 100 keV incident electrons. However, in submicron sized volumes, only the discrete models describe the high backscattering that should still be present around GNPs at these length scales. Sizeable differences (mostly above a factor of 2) are also found in the radial distribution of absorbed dose and secondary particles between the new and the existing Geant4 models. The degree to which these differences are due to intrinsic limitations of the condensed-history models or to differences in the underling scattering cross sections requires further investigation. Improved physics models for gold are necessary to better model the impact of GNPs in radiotherapy via Monte Carlo simulations. We implemented discrete electron transport models for gold in Geant4 that is applicable down to 10 eV including the modeling of the full de-excitation cascade. It is demonstrated that the new model has a significant positive impact on particle transport simulations in gold volumes with submicron dimensions compared to the existing Livermore and Penelope condensed-history models of Geant4. © 2018 American Association of Physicists in Medicine.
Liénard, Aurore; Delevallez, France; Razavi, Darius; Gibon, Anne-Sophie; Libert, Yves; Delvaux, Nicole; Marchal, Serge; Etienne, Anne-Marie; Bragard, Isabelle; Reynaert, Christine; Slachmuylder, Jean-Louis; Durieux, Jean-François; Farvacques, Christine; Scalliet, Pierre; Van Houtte, Paul; Coucke, Philippe; Merckaert, Isabelle
2016-05-01
The aim of this study was to assess the efficacy of a 38-h communication skills training program designed for multidisciplinary radiotherapy teams. Four radiotherapy teams were randomly assigned to a training program or to a waiting list. Assessments were scheduled at baseline (T1) and then after the training was completed or four months later (T2), respectively. Communication around radiotherapy delivery was assessed based on audio recordings of the first and last radiotherapy sessions in order to assess team members' communication skills and the expression of concerns by breast cancer patients (analyzed with content analysis software LaComm). 198 radiotherapy sessions were recorded. During the first radiotherapy sessions, members of the trained teams exhibited more assessment skills (p=0.048), provided more setting information (p<0.001), and used more social words (p=0.019) compared to the members of the untrained teams. During the last radiotherapy session, members of the trained teams used more assessment skills (p=0.004) and patients interacting with members of the trained teams expressed more sadness words (p=0.023). Training of multidisciplinary teams has the potential to transfer skills that affect the short exchanges that take place around radiotherapy delivery. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Zecchin, Massimo; Artico, Jessica; Morea, Gaetano; Severgnini, Mara; Bianco, Elisabetta; De Luca, Antonio; Fantasia, Anna Zorzin; Salvatore, Luca; Milan, Vittorino; Lucarelli, Matteo; Dissegna, Roberta; Cannatà, Antonio; Sinagra, Gianfranco
2018-04-01
During radiotherapy, in patients with implantable cardioverter-defibrillators (ICDs) malfunctions are considered more likely if doses more than 2 Gy reach the ICD site; however, most malfunctions occur with high-energy (>10 MV) radiations, and the risk is less defined using 6-MV linear accelerators. The purpose of the study is to experimentally evaluate the occurrence of malfunctions in ICDs radiated with a 6-MV linear accelerator at increasing photon doses. Thirty-two ICDs from all manufacturers (31 explanted and one demo) were evaluated; all devices with a sufficient battery charge underwent multiple radiations with a 6-MV photon beam reaching a cumulative dose at ICD site of 0.5, 1, 2, 3, 5 and 10 Gy and interrogated after every session. All antitachycardia therapies were left enabled; two ICDs were connected to a rhythm simulator (one simulating a complete atrioventricular block without ventricular activity) and visually monitored by external ECG and the ICD programmer during radiation. Thirteen ICDs were excluded before radiation because of battery depletion; after radiation up to the cumulative dose at the cardiac implantable electronic device site of 10 Gy, in the remaining 19 devices, programmation and battery charge remained unchanged and no switch to safety mode was observed; oversensing, pacing inhibition or inappropriate antitachycardia therapy were neither recorded nor visually observed during radiation. With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.
Chen, Jenny Ling-Yu; Cheng, Jason Chia-Hsien; Kuo, Sung-Hsin; Chan, Hsing-Min; Huang, Yu-Sen; Chen, Yu-Hsuan
2013-01-01
Since December 2009, after breast-conserving surgery for Stage 0–I cancer of the left breast, 21 women with relatively pendulous breasts underwent computed tomography prone and supine simulations. The adjuvant radiotherapy was 50 Gy in 25 fractions to the left breast alone. Four plans—conventional wedged tangents and forward intensity-modulated radiotherapy (fIMRT) in supine and prone positions—were generated. fIMRT generated better homogeneity in both positions. Prone position centralized the breast tissue by gravity and also shortened the breast width which led to better conformity in both planning techniques. Prone fIMRT significantly reduced doses to left lung, Level I and Level II axilla. The mean cardiac doses did not differ between positions. Among the four plans, prone fIMRT produced the best target dosimetry and normal organ sparing. In subgroup analysis, patients with absolute breast depth > 7 cm in the prone position or breast depth difference > 3 cm between positions had significant cardiac sparing with prone fIMRT. Sixteen patients with significant cardiac sparing in prone position were treated using prone fIMRT and the others using supine fIMRT. All patients received a supine electron tumor bed boost of 10 Gy in 5 fractions. No patients developed Grade 2 or worse acute or late toxicities. There was no difference in the number of segments or beams, monitor units, treatment time, or positioning reproducibility between prone and supine positions. At a median follow-up time of 26.8 months, no locoregional or distant recurrence or death was noted. PMID:23504450
Ding, George X; Alaei, Parham; Curran, Bruce; Flynn, Ryan; Gossman, Michael; Mackie, T Rock; Miften, Moyed; Morin, Richard; Xu, X George; Zhu, Timothy C
2018-05-01
With radiotherapy having entered the era of image guidance, or image-guided radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning and target localization. The imaging dose delivered may result in excessive dose to sensitive organs and potentially increase the chance of secondary cancers and, therefore, needs to be managed. This task group was charged with: a) providing an overview on imaging dose, including megavoltage electronic portal imaging (MV EPI), kilovoltage digital radiography (kV DR), Tomotherapy MV-CT, megavoltage cone-beam CT (MV-CBCT) and kilovoltage cone-beam CT (kV-CBCT), and b) providing general guidelines for commissioning dose calculation methods and managing imaging dose to patients. We briefly review the dose to radiotherapy (RT) patients resulting from different image guidance procedures and list typical organ doses resulting from MV and kV image acquisition procedures. We provide recommendations for managing the imaging dose, including different methods for its calculation, and techniques for reducing it. The recommended threshold beyond which imaging dose should be considered in the treatment planning process is 5% of the therapeutic target dose. Although the imaging dose resulting from current kV acquisition procedures is generally below this threshold, the ALARA principle should always be applied in practice. Medical physicists should make radiation oncologists aware of the imaging doses delivered to patients under their care. Balancing ALARA with the requirement for effective target localization requires that imaging dose be managed based on the consideration of weighing risks and benefits to the patient. © 2018 American Association of Physicists in Medicine.
SU-F-T-507: Modeling Cerenkov Emissions From Medical Linear Accelerators: A Monte Carlo Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrock, Z; Oldham, M; Adamson, J
2016-06-15
Purpose: Cerenkov emissions are a natural byproduct of MV radiotherapy but are typically ignored as inconsequential. However, Cerenkov photons may be useful for activation of drugs such as psoralen. Here, we investigate Cerenkov radiation from common radiotherapy beams using Monte Carlo simulations. Methods: GAMOS, a GEANT4-based framework for Monte Carlo simulations, was used to model 6 and 18MV photon beams from a Varian medical linac. Simulations were run to track Cerenkov production from these beams when irradiating a 50cm radius sphere of water. Electron contamination was neglected. 2 million primary photon histories were run for each energy, and values scoredmore » included integral dose and total track length of Cerenkov photons between 100 and 400 nm wavelength. By lowering process energy thresholds, simulations included low energy Bremsstrahlung photons to ensure comprehensive evaluation of UV production in the medium. Results: For the same number of primary photons, UV Cerenkov production for 18MV was greater than 6MV by a factor of 3.72 as determined by total track length. The total integral dose was a factor of 2.31 greater for the 18MV beam. Bremsstrahlung photons were a negligibly small component of photons in the wavelength range of interest, comprising 0.02% of such photons. Conclusion: Cerenkov emissions in water are 1.6x greater for 18MV than 6MV for the same integral dose. Future work will expand the analysis to include optical properties of tissues, and to investigate strategies to maximize Cerenkov emission per unit dose for MV radiotherapy.« less
Dedicated magnetic resonance imaging in the radiotherapy clinic.
Karlsson, Mikael; Karlsson, Magnus G; Nyholm, Tufve; Amies, Christopher; Zackrisson, Björn
2009-06-01
To introduce a novel technology arrangement in an integrated environment and outline the logistics model needed to incorporate dedicated magnetic resonance (MR) imaging in the radiotherapy workflow. An initial attempt was made to analyze the value and feasibility of MR-only imaging compared to computed tomography (CT) imaging, testing the assumption that MR is a better choice for target and healthy tissue delineation in radiotherapy. A 1.5-T MR unit with a 70-cm-bore size was installed close to a linear accelerator, and a special trolley was developed for transporting patients who were fixated in advance between the MR unit and the accelerator. New MR-based workflow procedures were developed and evaluated. MR-only treatment planning has been facilitated, thus avoiding all registration errors between CT and MR scans, but several new aspects of MR imaging must be considered. Electron density information must be obtained by other methods. Generation of digitally reconstructed radiographs (DRR) for x-ray setup verification is not straight forward, and reliable corrections of geometrical distortions must be applied. The feasibility of MR imaging virtual simulation has been demonstrated, but a key challenge to overcome is correct determination of the skeleton, which is often needed for the traditional approach of beam modeling. The trolley solution allows for a highly precise setup for soft tissue tumors without the invasive handling of radiopaque markers. The new logistics model with an integrated MR unit is efficient and will allow for improved tumor definition and geometrical precision without a significant loss of dosimetric accuracy. The most significant development needed is improved bone imaging.
Masoud Rahbari, Reza; Winkley, Lauren; Hill, Jacques; Tahir, Abdul Rahim Mohammed; McKay, Michael; Last, Andrew; Shakespeare, Thomas P; Dwyer, Patrick
2016-06-01
Oropharyngeal squamous cell carcinoma (OPSCC) incidence has increased over the past two decades largely because of an increase in human papilloma virus (HPV)-related OPSCC. We report here outcomes of definitive radiation therapy for OPSCC with simultaneous integrated boost intensity-modulated radiotherapy (IMRT) in a regional Australian cancer centre. We retrospectively reviewed electronic medical records (EMR) of all patients treated with IMRT for head and neck cancer. We included patients who received a curative intent IMRT for OPSCC (2010-2014). Of 61 patients, 80% were men, and the median age was 57 years. Ninety percent of our patients received concurrent systemic therapy, and 68% were p16 positive. The median radiotherapy dose received was 70 Gy in 35 fractions. The median follow up for surviving patients was 22 months. Twenty-four month actuarial data show that the loco-regional recurrence free, metastasis-free MFS, cancer-specific (CaSS) and overall survival percentages were 98.3%, 92.6%, 91% and 90.3%, respectively. We did not observe grades 4 or 5 acute or late toxicities, and 10 patients (16.2%) exhibited persistent grade 3 toxicity 6 months after completing the treatment. The results from curative IMRTs for OPSCC delivered in a regional cancer centre are comparable with results published by tertiary referral centres. A long-term follow up of this patient cohort will continue for further analyses and comparisons with tertiary centres. © 2016 The Royal Australian and New Zealand College of Radiologists.
Kumar, A. Sathish; Singh, I. Rabi Raja; Sharma, S. D.; Ravindran, B. Paul
2015-01-01
The main objective of this study was to investigate the characteristics of metal oxide semiconductor field effect transistor (MOSFET) dosimeter for kilovoltage (kV) X-ray beams in order to perform the in vivo dosimetry during image guidance in radiotherapy. The performance characteristics of high sensitivity MOSFET dosimeters were investigated for 80, 90, 100, 110, 120, and 125 kV X-ray beams used for imaging in radiotherapy. This study was performed using Clinac 2100 C/D medical electron linear accelerator with on-board imaging and kV cone beam computed tomography system. The characteristics studied in this work include energy dependence, angular dependence, and linearity. The X-ray beam outputs were measured as per American Association of Physicists in Medicine (AAPM) TG 61 recommendations using PTW parallel plate (PP) ionization chamber, which was calibrated in terms of air kerma (Nk) by the National Standard Laboratory. The MOSFET dosimeters were calibrated against the PP ionization chamber for all the kV X-ray beams and the calibration coefficient was found to be 0.11 cGy/mV with a standard deviation of about ±1%. The response of MOSFET was found to be energy independent for the kV X-ray energies used in this study. The response of the MOSFET dosimeter was also found independent of angle of incidence for the gantry angles in the range of 0° to 360° in-air as well as at 3 cm depth in tissue equivalent phantom. PMID:26500397
Lo Torto, Federico; Relucenti, Michela; Familiari, Giuseppe; Vaia, Nicola; Casella, Donato; Matassa, Roberto; Miglietta, Selenia; Marinozzi, Franco; Bini, Fabiano; Fratoddi, Ilaria; Sciubba, Fabio; Cassese, Raffaele; Tombolini, Vincenzo; Ribuffo, Diego
2018-05-17
The pathogenic mechanism underlying capsular contracture is still unknown. It is certainly a multifactorial process, resulting from human body reaction, biofilm activation, bacteremic seeding, or silicone exposure. The scope of the present article is to investigate the effect of hypofractionated radiotherapy protocol (2.66 Gy × 16 sessions) both on silicone and polyurethane breast implants. Silicone implants and polyurethane underwent irradiation according to a hypofractionated radiotherapy protocol for the treatment of breast cancer. After irradiation implant shells underwent mechanical, chemical, and microstructural evaluation by means of tensile testing, infrared spectra in attenuated total reflectance mode, nuclear magnetic resonance, and field emission scanning electron microscopy. At superficial analysis, irradiated silicone samples show several visible secondary and tertiary blebs. Polyurethane implants showed an open cell structure, which closely resembles a sponge. Morphological observation of struts from treated polyurethane sample shows a more compact structure, with significantly shorter and thicker struts compared with untreated sample. The infrared spectra in attenuated total reflectance mode spectra of irradiated and control samples were compared either for silicon and polyurethane samples. In the case of silicone-based membranes, treated and control specimens showed similar bands, with little differences in the treated one. Nuclear magnetic resonance spectra on the fraction soluble in CDCl3 support these observations. Tensile tests on silicone samples showed a softer behavior of the treated ones. Tensile tests on Polyurethane samples showed no significant differences. Polyurethane implants seem to be more resistant to radiotherapy damage, whereas silicone prosthesis showed more structural, mechanical, and chemical modifications.
Alabdoaburas, Mohamad M; Mege, Jean-Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Atilla; de Vathaire, Florent; Lefkopoulos, Dimitri; Diallo, Ibrahima
2015-11-08
The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.
Alabdoaburas, Mohamad M.; Mege, Jean‐Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Attila; de Vathaire, Florent; Lefkopoulos, Dimitri
2015-01-01
The purpose of this work was to experimentally investigate the out‐of‐field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off‐axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD‐700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel‐plane ionization chamber measurements. Also, out‐of‐field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12–15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10×10cm2 applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10×10cm2 applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out‐of‐field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long‐term effects. PACS number(s): 87.53.Bn, 87.56.bd, 87.56.J‐ PMID:26699572
2013-01-01
Purpose To evaluate the efficacy of low-dose radiotherapy in painful gonarthritis. Methods We assessed the medical records of 1037 patients with painful gonarthritis who had undergone low-dose radiotherapy between 1981 and 2008. The subjective patient perception of the response to irradiation as graded immediately or up to two months after the completion of a radiotherapy series was evaluated and correlated with age, gender, radiological grading and the duration of symptoms before radiotherapy. Moreover, we performed a mail survey to obtain additional long-term follow-up information and received one hundred and six evaluable questionnaires. Results We assessed 1659 series of radiotherapy in 1037 patients. In 79.3% of the cases the patients experienced a slight, marked or complete pain relief immediately or up to two months after the completion of radiotherapy. Gender, age and the duration of pain before radiotherapy did not have a significant influence on the response to irradiation. In contrast, severe signs of osteoarthritis were associated with more effective pain relief. In more than 50% of the patients who reported a positive response to irradiation a sustained period of symptomatic improvement was observed. Conclusions Our results confirm that low-dose radiotherapy is an effective treatment for painful osteoarthritis of the knee. In contrast to an earlier retrospective study, severe signs of osteoarthritis constituted a positive prognostic factor for the response to irradiation. A randomized trial is urgently required to compare radiotherapy with other treatment modalities. PMID:23369282
Seizure control following radiotherapy in patients with diffuse gliomas: a retrospective study
Rudà, Roberta; Magliola, Umberto; Bertero, Luca; Trevisan, Elisa; Bosa, Chiara; Mantovani, Cristina; Ricardi, Umberto; Castiglione, Anna; Monagheddu, Chiara; Soffietti, Riccardo
2013-01-01
Background Little information is available regarding the effect of conventional radiotherapy on glioma-related seizures. Methods In this retrospective study, we analyzed the seizure response and outcome following conventional radiotherapy in a cohort of 43 patients with glioma (33 grade II, 10 grade III) and medically intractable epilepsy. Results At 3 months after radiotherapy, seizure reduction was significant (≥50% reduction of frequency compared with baseline) in 31/43 patients (72%) of the whole series and in 25/33 patients (76%) with grade II gliomas, whereas at 12 months seizure reduction was significant in 26/34 (76%) and in 19/25 (76%) patients, respectively. Seizure reduction was observed more often among patients displaying an objective tumor response on MRI, but patients with no change on MRI also had a significant seizure reduction. Seizure freedom (Engel class I) was achieved at 12 months in 32% of all patients and in 38% of patients with grade II tumors. Timing of radiotherapy and duration of seizures prior to radiotherapy were significantly associated with seizure reduction. Conclusions This study showed that a high proportion of patients with medically intractable epilepsy from diffuse gliomas derive a significant and durable benefit from radiotherapy in terms of epilepsy control and that this positive effect is not strictly associated with tumor shrinkage as shown on MRI. Radiotherapy at tumor progression seems as effective as early radiotherapy after surgery. Prospective studies must confirm and better characterize the response to radiotherapy. PMID:23897633
Jang, Hyunsoo; Baek, Jong Geun; Jo, Sunmi
2015-01-01
Tolerance of the anal canal tends to be ignored in patients with cervical cancer undergoing whole pelvic radiotherapy. However, patients with hemorrhoids may be troubled with low radiation dose. We tried to analyze the dose-volume statistics of the anal canal in patients undergoing whole pelvic radiotherapy. The records of 31 patients with cervical cancer who received definite or postoperative radiotherapy at one institution were reviewed. Acute anal symptoms, such as anal pain and bleeding, were evaluated from radiotherapy start to 1 month after radiotherapy completion. Various clinical and dosimetric factors were analyzed to characterize relations with acute anal complications. The anal verge was located an average of 1.2 cm (range -0.6~3.9) below the lower border of the ischial tuberosity and an average of 2.7 cm (range -0.6~5.7) behind the sacral promontory level. The presence of hemorrhoids before radiotherapy was found to be significantly associated with acute radiation-induced anal symptoms (p = 0.001), and the mean induction dose for anal symptoms was 36.9 Gy. No patient without hemorrhoids developed an anal symptom during radiotherapy. Dosimetric analyses of V30 and V40 showed marginal correlations with anal symptoms (p = 0.07). The present study suggests a relation between acute anal symptoms following radiotherapy and acute hemorrhoid aggravation. Furthermore, the location of the anal verge was found to be variable, and consequently doses administered to the anal canal also varied substantially. Our results caution careful radiation treatment planning for whole pelvic radiotherapy, and that proper clinical management be afforded patients with hemorrhoids during radiotherapy.
Hill, Amanda; Kiss, Nicole; Hodgson, Belinda; Crowe, Timothy C; Walsh, Adam D
2011-02-01
Patients with gastrointestinal cancers are susceptible to nutritional deterioration which may be compounded by radiotherapy treatment toxicities. This study aimed to determine whether nutritional status at radiotherapy commencement or changes in nutritional status throughout radiotherapy were associated with treatment toxicity and outcomes in gastrointestinal cancer patients. Seventy-three gastrointestinal cancer patients receiving curative radiotherapy underwent medical record audits assessing body weight, radiotherapy toxicity, unplanned treatment breaks or hospital admissions and completion of prescribed treatment/s. Nutritional status was assessed in a subset of patients (n = 11) using the Patient-Generated Subjective Global Assessment tool. Seventy-five percent of patients lost weight throughout radiotherapy. Weight loss was significantly greater in patients experiencing unplanned radiotherapy breaks (-3.1% vs -1.6%, p < 0.05) and in patients not completing prescribed chemotherapy (-3.3% vs -1.6%, p < 0.05). Toxicity severity was strongly correlated with Patient-Generated Subjective Global Assessment score (rho = 0.839, p < 0.001) and was increased in patients experiencing unplanned admissions compared to those without admission (42.1% vs 9.3% with grade 3 toxicity respectively, p < 0.001). Deterioration in nutritional status during radiotherapy (as measured by weight loss) may be associated with poorer short-term treatment outcomes in gastrointestinal cancer patients. Patient numbers were too small to definitively determine the effect of nutritional status at radiotherapy commencement or changes in nutritional status throughout radiotherapy (defined by PG-SGA) on treatment outcomes. Further research is required to investigate this in larger, longer-term studies. Copyright © 2010. Published by Elsevier Ltd.
Contribution of FDOPA PET to radiotherapy planning for advanced glioma
NASA Astrophysics Data System (ADS)
Dowson, Nicholas; Fay, Michael; Thomas, Paul; Jeffree, Rosalind; McDowall, Robert; Winter, Craig; Coulthard, Alan; Smith, Jye; Gal, Yaniv; Bourgeat, Pierrick; Salvado, Olivier; Crozier, Stuart; Rose, Stephen
2014-03-01
Despite radical treatment with surgery, radiotherapy and chemotherapy, advanced gliomas recur within months. Geographic misses in radiotherapy planning may play a role in this seemingly ineluctable recurrence. Planning is typically performed on post-contrast MRIs, which are known to underreport tumour volume relative to FDOPA PET scans. FDOPA PET fused with contrast enhanced MRI has demonstrated greater sensitivity and specificity than MRI alone. One sign of potential misses would be differences between gross target volumes (GTVs) defined using MRI alone and when fused with PET. This work examined whether such a discrepancy may occur. Materials and Methods: For six patients, a 75 minute PET scan using 3,4-dihydroxy-6-18F-fluoro-L-phynel-alanine (18F-FDOPA) was taken within 2 days of gadolinium enhanced MRI scans. In addition to standard radiotherapy planning by an experienced radiotherapy oncologist, a second gross target volume (GTV) was defined by an experienced nuclear medicine specialist for fused PET and MRI, while blinded to the radiotherapy plans. The volumes from standard radiotherapy planning were compared to the PET defined GTV. Results: The comparison indicated radiotherapy planning would change in several cases if FDOPA PET data was available. PET-defined contours were external to 95% prescribed dose for several patients. However, due to the radiotherapy margins, the discrepancies were relatively small in size and all received a dose of 50 Gray or more. Conclusions: Given the limited size of the discrepancies it is uncertain that geographic misses played a major role in patient outcome. Even so, the existence of discrepancies indicates that FDOPA PET could assist in better defining margins when planning radiotherapy for advanced glioma, which could be important for highly conformal radiotherapy plans.
Cardiac Side-effects From Breast Cancer Radiotherapy.
Taylor, C W; Kirby, A M
2015-11-01
Breast cancer radiotherapy reduces the risk of cancer recurrence and death. However, it usually involves some radiation exposure of the heart and analyses of randomised trials have shown that it can increase the risk of heart disease. Estimates of the absolute risks of radiation-related heart disease are needed to help oncologists plan each individual woman's treatment. The risk for an individual woman varies according to her estimated cardiac radiation dose and her background risk of ischaemic heart disease in the absence of radiotherapy. When it is known, this risk can then be compared with the absolute benefit of the radiotherapy. At present, many UK cancer centres are already giving radiotherapy with mean heart doses of less than 3 Gy and for most women the benefits of the radiotherapy will probably far outweigh the risks. Technical approaches to minimising heart dose in breast cancer radiotherapy include optimisation of beam angles, use of multileaf collimator shielding, intensity-modulated radiotherapy, treatment in a prone position, treatment in deep inspiration (including the use of breath-hold and gating techniques), proton therapy and partial breast irradiation. The multileaf collimator is suitable for many women with upper pole left breast cancers, but for women with central or lower pole cancers, breath-holding techniques are now recommended in national UK guidelines. Ongoing work aims to identify ways of irradiating pan-regional lymph nodes that are effective, involve minimal exposure of organs at risk and are feasible to plan, deliver and verify. These will probably include wide tangent-based field-in-field intensity-modulated radiotherapy or arc radiotherapy techniques in combination with deep inspiratory breath-hold, and proton beam irradiation for women who have a high predicted heart dose from intensity-modulated radiotherapy. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Palta, Manisha; Palta, Priya; Bhavsar, Nrupen A; Horton, Janet K; Blitzblau, Rachel C
2015-01-15
The Cancer and Leukemia Group B (CALGB) 9343 randomized phase 3 trial established lumpectomy and adjuvant therapy with tamoxifen alone, rather than both radiotherapy and tamoxifen, as a reasonable treatment course for women aged >70 years with clinical stage I (AJCC 7th edition), estrogen receptor-positive breast cancer. An analysis of the Surveillance, Epidemiology, and End Results (SEER) registry was undertaken to assess practice patterns before and after the publication of this landmark study. The SEER database from 2000 to 2009 was used to identify 40,583 women aged ≥70 years who were treated with breast-conserving surgery for clinical stage I, estrogen receptor-positive and/or progesterone receptor-positive breast cancer. The percentage of patients receiving radiotherapy and the type of radiotherapy delivered was assessed over time. Administration of radiotherapy was further assessed across age groups; SEER cohort; and tumor size, grade, and laterality. Approximately 68.6% of patients treated between 2000 and 2004 compared with 61.7% of patients who were treated between 2005 and 2009 received some form of adjuvant radiotherapy (P < .001). Coinciding with a decline in the use of external beam radiotherapy, there was an increase in the use of implant radiotherapy from 1.4% between 2000 and 2004 to 6.2% between 2005 to 2009 (P < .001). There were significant reductions in the frequency of radiotherapy delivery over time across age groups, tumor size, and tumor grade and regardless of laterality (P < .001 for all). Randomized phase 3 data support the omission of adjuvant radiotherapy in elderly women with early-stage breast cancer. Analysis of practice patterns before and after the publication of these data indicates a significant decline in radiotherapy use; however, nearly two-thirds of women continue to receive adjuvant radiotherapy. © 2014 American Cancer Society.
Cost-effectiveness of modern radiotherapy techniques in locally advanced pancreatic cancer.
Murphy, James D; Chang, Daniel T; Abelson, Jon; Daly, Megan E; Yeung, Heidi N; Nelson, Lorene M; Koong, Albert C
2012-02-15
Radiotherapy may improve the outcome of patients with pancreatic cancer but at an increased cost. In this study, the authors evaluated the cost-effectiveness of modern radiotherapy techniques in the treatment of locally advanced pancreatic cancer. A Markov decision-analytic model was constructed to compare the cost-effectiveness of 4 treatment regimens: gemcitabine alone, gemcitabine plus conventional radiotherapy, gemcitabine plus intensity-modulated radiotherapy (IMRT); and gemcitabine with stereotactic body radiotherapy (SBRT). Patients transitioned between the following 5 health states: stable disease, local progression, distant failure, local and distant failure, and death. Health utility tolls were assessed for radiotherapy and chemotherapy treatments and for radiation toxicity. SBRT increased life expectancy by 0.20 quality-adjusted life years (QALY) at an increased cost of $13,700 compared with gemcitabine alone (incremental cost-effectiveness ratio [ICER] = $69,500 per QALY). SBRT was more effective and less costly than conventional radiotherapy and IMRT. An analysis that excluded SBRT demonstrated that conventional radiotherapy had an ICER of $126,800 per QALY compared with gemcitabine alone, and IMRT had an ICER of $1,584,100 per QALY compared with conventional radiotherapy. A probabilistic sensitivity analysis demonstrated that the probability of cost-effectiveness at a willingness to pay of $50,000 per QALY was 78% for gemcitabine alone, 21% for SBRT, 1.4% for conventional radiotherapy, and 0.01% for IMRT. At a willingness to pay of $200,000 per QALY, the probability of cost-effectiveness was 73% for SBRT, 20% for conventional radiotherapy, 7% for gemcitabine alone, and 0.7% for IMRT. The current results indicated that IMRT in locally advanced pancreatic cancer exceeds what society considers cost-effective. In contrast, combining gemcitabine with SBRT increased clinical effectiveness beyond that of gemcitabine alone at a cost potentially acceptable by today's standards. Copyright © 2011 American Cancer Society.
Effectiveness of Radiotherapy for Elderly Patients With Glioblastoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Jacob; Tsai, Ya-Yu; Chinnaiyan, Prakash
Purpose: Radiotherapy plays a central role in the definitive treatment of glioblastoma. However, the optimal management of elderly patients with glioblastoma remains controversial, as the relative benefit in this patient population is unclear. To better understand the role that radiation plays in the treatment of glioblastoma in the elderly, we analyzed factors influencing patient survival using a large population-based registry. Methods and Materials: A total of 2,836 patients more than 70 years of age diagnosed with glioblastoma between 1993 and 2005 were identified from the Surveillance, Epidemiology, and End Results (SEER) registry. Demographic and clinical variables used in the analysismore » included gender, ethnicity, tumor size, age at diagnosis, surgery, and radiotherapy. Cancer-specific survival and overall survival were evaluated using the Kaplan-Meier method. Univariate and multivariate analysis were performed using Cox regression. Results: Radiotherapy was administered in 64% of these patients, and surgery was performed in 68%. Among 2,836 patients, 46% received surgery and radiotherapy, 22% underwent surgery only, 18% underwent radiotherapy only, and 14% did not undergo either treatment. The median survival for patients who underwent surgery and radiotherapy was 8 months. The median survival for patients who underwent radiotherapy only was 4 months, and for patients who underwent surgery only was 3 months. Those who received neither surgery nor radiotherapy had a median survival of 2 months (p < 0.001). Multivariate analysis showed that radiotherapy significantly improved cancer-specific survival (hazard ratio [HR], 0.43, 95% confidence interval [CI] 0.38-0.49) after adjusting for surgery, tumor size, gender, ethnicity, and age at diagnosis. Other factors associated with Cancer-specific survival included surgery, tumor size, age at diagnosis, and ethnicity. Analysis using overall survival as the endpoint yielded very similar results. Conclusions: Elderly patients with glioblastoma who underwent radiotherapy had improved cancer-specific survival and overall survival compared to patients who did not receive radiotherapy.« less
[Radiotherapy in cancers of the oesophagus, the gastric cardia and the stomach].
Créhange, G; Huguet, F; Quero, L; N'Guyen, T V; Mirabel, X; Lacornerie, T
2016-09-01
Localized oesophageal and gastric cancers have a poor prognosis. In oesophageal cancer, external radiotherapy combined with concomitant chemotherapy is accepted as part of the therapeutic armamentarium in a curative intent in the preoperative setting for resectable tumours; or without surgery in inoperable patients or non-resectable tumours due to wide local and/or regional extension. Data from the literature show conflicting results with no clinical evidence in favour of either a unique dose protocol or consensual target volume definition in the setting of exclusive chemoradiation. In the preoperative setting, chemoradiotherapy has become the standard in oesophageal cancer, even though there is no evidence that surgery may be beneficial in locally advanced tumours that respond to radiotherapy and chemotherapy. The main cause of failure after exclusive chemoradiotherapy in oesophageal cancer is locoregional relapse suggesting that doses and volumes usually considered may be inadequate. In gastric cancer, radiotherapy may be indicated postoperatively in patients with resected tumours that include less than D2 lymph node dissection or in the absence of perioperative chemotherapy. Preoperative chemoradiotherapy in gastric cancers is still under investigation. The evolving techniques of external radiotherapy, such as image-guided radiotherapy (IMRT) and volumetric modulated arctherapy (VMAT) have reduced the volume of lung and heart exposed to radiation, which seems to have diminished radiotherapy-related morbi-mortality rates. Given this, quality assurance for radiotherapy and protocols for radiotherapy delivery must be better standardized. This article on the indications for radiotherapy and the techniques used in oesophageal and gastric cancers is included in a special issue dedicated to national recommendations from the French society of radiation oncology (SFRO) on radiotherapy indications, planning, dose prescription, and techniques of radiotherapy delivery. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Radiotherapy with or without chemotherapy in muscle-invasive bladder cancer.
James, Nicholas D; Hussain, Syed A; Hall, Emma; Jenkins, Peter; Tremlett, Jean; Rawlings, Christine; Crundwell, Malcolm; Sizer, Bruce; Sreenivasan, Thiagarajan; Hendron, Carey; Lewis, Rebecca; Waters, Rachel; Huddart, Robert A
2012-04-19
Radiotherapy is an alternative to cystectomy in patients with muscle-invasive bladder cancer. In other disease sites, synchronous chemoradiotherapy has been associated with increased local control and improved survival, as compared with radiotherapy alone. In this multicenter, phase 3 trial, we randomly assigned 360 patients with muscle-invasive bladder cancer to undergo radiotherapy with or without synchronous chemotherapy. The regimen consisted of fluorouracil (500 mg per square meter of body-surface area per day) during fractions 1 to 5 and 16 to 20 of radiotherapy and mitomycin C (12 mg per square meter) on day 1. Patients were also randomly assigned to undergo either whole-bladder radiotherapy or modified-volume radiotherapy (in which the volume of bladder receiving full-dose radiotherapy was reduced) in a partial 2-by-2 factorial design (results not reported here). The primary end point was survival free of locoregional disease. Secondary end points included overall survival and toxic effects. At 2 years, rates of locoregional disease-free survival were 67% (95% confidence interval [CI], 59 to 74) in the chemoradiotherapy group and 54% (95% CI, 46 to 62) in the radiotherapy group. With a median follow-up of 69.9 months, the hazard ratio in the chemoradiotherapy group was 0.68 (95% CI, 0.48 to 0.96; P=0.03). Five-year rates of overall survival were 48% (95% CI, 40 to 55) in the chemoradiotherapy group and 35% (95% CI, 28 to 43) in the radiotherapy group (hazard ratio, 0.82; 95% CI, 0.63 to 1.09; P=0.16). Grade 3 or 4 adverse events were slightly more common in the chemoradiotherapy group than in the radiotherapy group during treatment (36.0% vs. 27.5%, P=0.07) but not during follow-up (8.3% vs. 15.7%, P=0.07). Synchronous chemotherapy with fluorouracil and mitomycin C combined with radiotherapy significantly improved locoregional control of bladder cancer, as compared with radiotherapy alone, with no significant increase in adverse events. (Funded by Cancer Research U.K.; BC2001 Current Controlled Trials number, ISRCTN68324339.).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onal, Cem, E-mail: hcemonal@hotmail.com; Arslan, Gungor; Dolek, Yemliha
2016-01-01
The aim of this study is to evaluate the incidental testicular doses during prostate radiation therapy with intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) at different energies. Dosimetric data of 15 patients with intermediate-risk prostate cancer who were treated with radiotherapy were analyzed. The prescribed dose was 78 Gy in 39 fractions. Dosimetric analysis compared testicular doses generated by 7-field intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy with a single arc at 6, 10, and 15 MV energy levels. Testicular doses calculated from the treatment planning system and doses measured from the detectors were analyzed. Mean testicular doses from themore » intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy per fraction calculated in the treatment planning system were 16.3 ± 10.3 cGy vs 21.5 ± 11.2 cGy (p = 0.03) at 6 MV, 13.4 ± 10.4 cGy vs 17.8 ± 10.7 cGy (p = 0.04) at 10 MV, and 10.6 ± 8.5 cGy vs 14.5 ± 8.6 cGy (p = 0.03) at 15 MV, respectively. Mean scattered testicular doses in the phantom measurements were 99.5 ± 17.2 cGy, 118.7 ± 16.4 cGy, and 193.9 ± 14.5 cGy at 6, 10, and 15 MV, respectively, in the intensity-modulated radiotherapy plans. In the volumetric-modulated arc radiotherapy plans, corresponding testicular doses per course were 90.4 ± 16.3 cGy, 103.6 ± 16.4 cGy, and 139.3 ± 14.6 cGy at 6, 10, and 15 MV, respectively. In conclusions, this study was the first to measure the incidental testicular doses by intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy plans at different energy levels during prostate-only irradiation. Higher photon energy and volumetric-modulated arc radiotherapy plans resulted in higher incidental testicular doses compared with lower photon energy and intensity-modulated radiotherapy plans.« less
Lin, Zhixiong; Wu, Vincent Wing-Cheung; Lin, Jing; Feng, Huiting; Chen, Longhua
2011-01-01
Radiation-induced thyroid disorders have been reported in radiotherapy of head and neck cancers. This study evaluated the radiation-induced damages to thyroid gland in patients with nasopharyngeal carcinoma (NPC). Forty-five patients with NPC treated by radiotherapy underwent baseline thyroid hormones (free triiodothyronine, free thyroxine [fT4], and thyrotropin [TSH]) examination and CT scan before radiotherapy. The volume of the thyroid gland was calculated by delineating the structure in the corresponding CT slices using the radiotherapy treatment planning system. The thyroid doses were estimated using the treatment planning system. Subsequent CT scans were conducted at 6, 12, and 18 months after radiotherapy, whereas the hormone levels were assessed at 3, 6, 12, and 18 months after radiotherapy. Trend lines of the volume and hormone level changes against time were plotted. The relationship between the dose and the change of thyroid volume and hormone levels were evaluated using the Pearson correlation test. An average of 20% thyroid volume reduction in the first 6 months and a further 8% shrinkage at 12 months after radiotherapy were observed. The volume reduction was dependent on the mean thyroid doses at 6, 12, and 18 months after radiotherapy (r = -0.399, -0.472, and -0.417, respectively). Serum free triiodothyronine and fT4 levels showed mild changes of <2.5% at 6 months, started to drop by 8.8% and 11.3%, respectively, at 12 months, and became stable at 18 months. The mean serum TSH level increased mildly at 6 months after radiotherapy and more steeply after 18 months. At 18 months after radiotherapy, 12 patients had primary hypothyroidism with an elevated serum TSH, in which 4 of them also presented with low serum fT4. There was a significant difference (p = 0.014) in the mean thyroid doses between patients with hypothyroidism and normal thyroid function. Radiotherapy for patients with NPC caused radiation-induced changes of the thyroid gland. The shrinkage of the gland was greatest in the first 6 months after radiotherapy, whereas the serum fT4 and TSH levels changed at 12 months. Radiation-induced changes were dependent on the mean dose to the gland. Therefore, measures to reduce the thyroid dose in radiotherapy should be considered.
Defining Action Levels for In Vivo Dosimetry in Intraoperative Electron Radiotherapy.
López-Tarjuelo, Juan; Morillo-Macías, Virginia; Bouché-Babiloni, Ana; Ferrer-Albiach, Carlos; Santos-Serra, Agustín
2016-06-01
In vivo dosimetry is recommended in intraoperative electron radiotherapy (IOERT). To perform real-time treatment monitoring, action levels (ALs) have to be calculated. Empirical approaches based on observation of samples have been reported previously, however, our aim is to present a predictive model for calculating ALs and to verify their validity with our experimental data. We considered the range of absorbed doses delivered to our detector by means of the percentage depth dose for the electron beams used. Then, we calculated the absorbed dose histograms and convoluted them with detector responses to obtain probability density functions in order to find ALs as certain probability levels. Our in vivo dosimeters were reinforced TN-502RDM-H mobile metal-oxide-semiconductor field-effect transistors (MOSFETs). Our experimental data came from 30 measurements carried out in patients undergoing IOERT for rectal, breast, sarcoma, and pancreas cancers, among others. The prescribed dose to the tumor bed was 90%, and the maximum absorbed dose was 100%. The theoretical mean absorbed dose was 90.3% and the measured mean was 93.9%. Associated confidence intervals at P = .05 were 89.2% and 91.4% and 91.6% and 96.4%, respectively. With regard to individual comparisons between the model and the experiment, 37% of MOSFET measurements lay outside particular ranges defined by the derived ALs. Calculated confidence intervals at P = .05 ranged from 8.6% to 14.7%. The model can describe global results successfully but cannot match all the experimental data reported. In terms of accuracy, this suggests an eventual underestimation of tumor bed bleeding or detector alignment. In terms of precision, it will be necessary to reduce positioning uncertainties for a wide set of location and treatment postures, and more precise detectors will be required. Planning and imaging tools currently under development will play a fundamental role. © The Author(s) 2015.
WE-G-BRA-04: Common Errors and Deficiencies in Radiation Oncology Practice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kry, S; Dromgoole, L; Alvarez, P
Purpose: Dosimetric errors in radiotherapy dose delivery lead to suboptimal treatments and outcomes. This work reviews the frequency and severity of dosimetric and programmatic errors identified by on-site audits performed by the IROC Houston QA center. Methods: IROC Houston on-site audits evaluate absolute beam calibration, relative dosimetry data compared to the treatment planning system data, and processes such as machine QA. Audits conducted from 2000-present were abstracted for recommendations, including type of recommendation and magnitude of error when applicable. Dosimetric recommendations corresponded to absolute dose errors >3% and relative dosimetry errors >2%. On-site audits of 1020 accelerators at 409 institutionsmore » were reviewed. Results: A total of 1280 recommendations were made (average 3.1/institution). The most common recommendation was for inadequate QA procedures per TG-40 and/or TG-142 (82% of institutions) with the most commonly noted deficiency being x-ray and electron off-axis constancy versus gantry angle. Dosimetrically, the most common errors in relative dosimetry were in small-field output factors (59% of institutions), wedge factors (33% of institutions), off-axis factors (21% of institutions), and photon PDD (18% of institutions). Errors in calibration were also problematic: 20% of institutions had an error in electron beam calibration, 8% had an error in photon beam calibration, and 7% had an error in brachytherapy source calibration. Almost all types of data reviewed included errors up to 7% although 20 institutions had errors in excess of 10%, and 5 had errors in excess of 20%. The frequency of electron calibration errors decreased significantly with time, but all other errors show non-significant changes. Conclusion: There are many common and often serious errors made during the establishment and maintenance of a radiotherapy program that can be identified through independent peer review. Physicists should be cautious, particularly in areas highlighted herein that show a tendency for errors.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warkentin, H; Bubric, K; Giovannetti, H
2016-06-15
Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment.more » A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document or procedure into clinical use, associated risks can be identified and mitigated before patient care and clinical workflow are impacted.« less
[Task sharing with radiotherapy technicians in image-guided radiotherapy].
Diaz, O; Lorchel, F; Revault, C; Mornex, F
2013-10-01
The development of accelerators with on-board imaging systems now allows better target volumes reset at the time of irradiation (image-guided radiotherapy [IGRT]). However, these technological advances in the control of repositioning led to a multiplication of tasks for each actor in radiotherapy and increase the time available for the treatment, whether for radiotherapy technicians or radiation oncologists. As there is currently no explicit regulatory framework governing the use of IGRT, some institutional experiments show that a transfer is possible between radiation oncologists and radiotherapy technicians for on-line verification of image positioning. Initial training for every technical and drafting procedures within institutions will improve audit quality by reducing interindividual variability. Copyright © 2013. Published by Elsevier SAS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joseph, Ackeem; Herrera, David; Hijal, Tarek
We describe a method for predicting waiting times in radiation oncology. Machine learning is a powerful predictive modelling tool that benefits from large, potentially complex, datasets. The essence of machine learning is to predict future outcomes by learning from previous experience. The patient waiting experience remains one of the most vexing challenges facing healthcare. Waiting time uncertainty can cause patients, who are already sick and in pain, to worry about when they will receive the care they need. In radiation oncology, patients typically experience three types of waiting: Waiting at home for their treatment plan to be prepared Waiting inmore » the waiting room for daily radiotherapy Waiting in the waiting room to see a physician in consultation or follow-up These waiting periods are difficult for staff to predict and only rough estimates are typically provided, based on personal experience. In the present era of electronic health records, waiting times need not be so uncertain. At our centre, we have incorporated the electronic treatment records of all previously-treated patients into our machine learning model. We found that the Random Forest Regression model provides the best predictions for daily radiotherapy treatment waiting times (type 2). Using this model, we achieved a median residual (actual minus predicted value) of 0.25 minutes and a standard deviation residual of 6.5 minutes. The main features that generated the best fit model (from most to least significant) are: Allocated time, median past duration, fraction number and the number of treatment fields.« less
NASA Astrophysics Data System (ADS)
Giulietti, Antonio
2017-05-01
Radiation therapy of tumors progresses continuously and so do devices, sharing a global market of about $ 4 billions, growing at an annual rate exceeding 5%. Most of the progress involves tumor targeting, multi-beam irradiation, reduction of damage on healthy tissues and critical organs, dose fractioning. This fast-evolving scenario is the moving benchmark for the progress of the laser-based accelerators towards clinical uses. As for electrons, both energy and dose requested by radiotherapy are available with plasma accelerators driven by lasers in the power range of tens of TW but several issues have still to be faced before getting a prototype device for clinical tests. They include capability of varying electron energy, stability of the process, reliability for medical users. On the other side hadron therapy, presently applied to a small fraction of cases but within an exponential growth, is a primary option for the future. With such a strong motivation, research on laser-based proton/ion acceleration has been supported in the last decade in order to get performances suitable to clinical standards. None of these performances has been achieved so far with laser techniques. In the meantime a rich crop of data have been obtained in radiobiological experiments performed with beams of particles produced with laser techniques. It is quite significant however that most of the experiments have been performed moving bio samples to laser labs, rather moving laser equipment to bio labs or clinical contexts. This give us the measure that laser community cannot so far provide practical devices usable by non-laser people.
NASA Astrophysics Data System (ADS)
Andreasen, Daniel; Edmund, Jens M.; Zografos, Vasileios; Menze, Bjoern H.; Van Leemput, Koen
2016-03-01
In radiotherapy treatment planning that is only based on magnetic resonance imaging (MRI), the electron density information usually obtained from computed tomography (CT) must be derived from the MRI by synthesizing a so-called pseudo CT (pCT). This is a non-trivial task since MRI intensities are neither uniquely nor quantitatively related to electron density. Typical approaches involve either a classification or regression model requiring specialized MRI sequences to solve intensity ambiguities, or an atlas-based model necessitating multiple registrations between atlases and subject scans. In this work, we explore a machine learning approach for creating a pCT of the pelvic region from conventional MRI sequences without using atlases. We use a random forest provided with information about local texture, edges and spatial features derived from the MRI. This helps to solve intensity ambiguities. Furthermore, we use the concept of auto-context by sequentially training a number of classification forests to create and improve context features, which are finally used to train a regression forest for pCT prediction. We evaluate the pCT quality in terms of the voxel-wise error and the radiologic accuracy as measured by water-equivalent path lengths. We compare the performance of our method against two baseline pCT strategies, which either set all MRI voxels in the subject equal to the CT value of water, or in addition transfer the bone volume from the real CT. We show an improved performance compared to both baseline pCTs suggesting that our method may be useful for MRI-only radiotherapy.
Song, Yanbo; Zhang, Miao; Gan, Lu; Chen, Xiaopin; Zhang, Tao; Yue, Ning J; Goyal, Sharad; Haffty, Bruce; Ren, Guosheng
2016-05-31
Electronic tissue compensation (eComp) is an external beam planning technique allowing user to manually generate dynamic beam fluence to produce more uniform or modulated dose distribution. In this study, we compared the effectiveness between conventional three-dimensional conformal radiotherapy (3DCRT) and eComp for whole breast irradiation. 3DCRT and eComp planning techniques were used to generate treatment plans for 60 whole breast patients, respectively. The planning goal was to cover 95% of the planning target volume (PTV) with 95% of the prescription dose while minimizing doses to lung, heart, and skin. Comparing to 3DCRT plans, on the average, eComp treatment planning process was about 7 minutes longer, but resulted in lower lung V20Gy, lower mean skin dose, with similar heart dose. The benefits were more pronounced for larger breast patients. Statistical analyses were performed between critical organ doses and patient anatomic features, i.e., central lung distance (CLD), maximal heart distance (MHD), maximal heart length (MHL) and breast separation (BS) to explore any correlations and planning method selection. It was found that to keep the lung V20Gy lower than 20% and mean skin dose lower than 85% of the prescription dose, eComp was the preferred method for patients with more than 2.3 cm CLD or larger than 22.5 cm BS. The study results may be useful in providing a handy criterion in clinical practice allowing us to easily choose between different planning techniques to satisfy the planning goal with minimal increase in complexity and cost.
Makurat, Samanta; Chomicz-Mańka, Lidia; Rak, Janusz
2016-08-18
Although 5-bromo-2'-deoxyuridine (5BrdU) possesses significant radiosensitizing power in vitro, clinical studies do not confirm any advantages of radiotherapy employing 5BrdU. This situation calls for a continuous search for efficient radiosensitizers. Using the proposed mechanism of radiosensitization by 5BrdU, we propose a series of 5-substituted uracils, XYU, that should undergo efficient dissociative electron attachment. The DFT-calculated thermodynamic and kinetic data concerning the XYU degradations induced by electron addition suggests that some of the scrutinized derivatives have much better characteristics than 5BrdU itself. Synthesis of these promising candidates for radiosensitizers, followed by studies of their radiosensitizing properties in DNA context, and ultimately in cancer cells, are further steps to confirm their potential applicability in anticancer treatment. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Beddar, A. S.; Tailor, R. C.
2004-04-01
A new approach to intraoperative radiation therapy led to the development of mobile linear electron accelerators that provide lower electron energy beams than the usual conventional accelerators commonly encountered in radiotherapy. Such mobile electron accelerators produce electron beams that have nominal energies of 4, 6, 9 and 12 MeV. This work compares the absorbed dose output calibrations using both the AAPM TG-51 and TG-21 dose calibration protocols for two types of ion chambers: a plane-parallel (PP) ionization chamber and a cylindrical ionization chamber. Our results indicate that the use of a 'Markus' PP chamber causes 2 3% overestimation in dose output determination if accredited dosimetry-calibration laboratory based chamber factors \\big(N_{{\\rm D},{\\rm w}}^{{}^{60}{\\rm Co}}, N_x\\big) are used. However, if the ionization chamber factors are derived using a cross-comparison at a high-energy electron beam, then a good agreement is obtained (within 1%) with a calibrated cylindrical chamber over the entire energy range down to 4 MeV. Furthermore, even though the TG-51 does not recommend using cylindrical chambers at the low energies, our results show that the cylindrical chamber has a good agreement with the PP chamber not only at 6 MeV but also down to 4 MeV electron beams.
Olschewski, Thomas; Seegenschmiedt, Michael Heinrich
2006-11-01
This patterns-of-care study was performed to define the current clinical experience with radiotherapy of Langerhans' cell histiocytosis in adults in Germany and to define open questions resulting from this study. A standardized questionnaire was sent to 198 German radiotherapy institutions. Data about patient characteristics, stage of disease, practice and fractionation of radiotherapy, outcome of therapy, etc. were systematically evaluated. 123 of 198 institutions answered the complete questionnaire (62.1%). Only 23 of the 123 institutions (18.7%) reported experience with radiotherapy of Langerhans' cell histiocytosis of adults. 18 institutions with 98 patients were evaluable. The majority of patients (72 of 98) was treated on a linear accelerator. The median single dose of radiotherapy was 2 Gy, while the median total dose was 24 Gy. 81 of 89 evaluable patients (91%) reached a local control of the treated lesion(s), 69 of those had a complete remission. Eight of 89 patients (9%) developed an in-field recurrence. 87.8% of patients experienced no acute and 97% of patients no late side effects of radiotherapy. Clinical experience with radiotherapy of Langerhans' cell histiocytosis in adults in Germany is still very limited. Nevertheless, the clinical results-with high remission and local control rates-confirm the effectiveness of radiotherapy in the multidisciplinary treatment of this disease. Due to the small number of patients in this study despite higher incidence rates, the knowledge of this disease has to be multiplied in Germany. Future patients should be systematically included into a prospective radiotherapy registry.
Winter, René M; Leibfarth, Sara; Schmidt, Holger; Zwirner, Kerstin; Mönnich, David; Welz, Stefan; Schwenzer, Nina F; la Fougère, Christian; Nikolaou, Konstantin; Gatidis, Sergios; Zips, Daniel; Thorwarth, Daniela
2018-05-07
Functional PET/MRI has great potential to improve radiotherapy planning (RTP). However, data integration requires imaging with radiotherapy-specific patient positioning. Here, we investigated the feasibility and image quality of radiotherapy-customized PET/MRI in head-and-neck cancer (HNC) patients using a dedicated hardware setup. Ten HNC patients were examined with simultaneous PET/MRI before treatment, with radiotherapy and diagnostic scan setup, respectively. We tested feasibility of radiotherapy-specific patient positioning and compared the image quality between both setups by pairwise image analysis of 18 F-FDG-PET, T1/T2-weighted and diffusion-weighted MRI. For image quality assessment, similarity measures including average symmetric surface distance (ASSD) of PET and MR-based tumor contours, MR signal-to-noise ratio (SNR) and mean apparent diffusion coefficient (ADC) value were used. PET/MRI in radiotherapy position was feasible - all patients were successfully examined. ASSD (median/range) of PET and MR contours was 0.6 (0.4-1.2) and 0.9 (0.5-1.3) mm, respectively. For T2-weighted MRI, a reduced SNR of -26.2% (-39.0--11.7) was observed with radiotherapy setup. No significant difference in mean ADC was found. Simultaneous PET/MRI in HNC patients using radiotherapy positioning aids is clinically feasible. Though SNR was reduced, the image quality obtained with a radiotherapy setup meets RTP requirements and the data can thus be used for personalized RTP. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.
... most common types of cancer treatment are surgery, radiotherapy, and chemotherapy. Treatment is aimed at removing the ... vital organs, such as the liver or brain. Radiotherapy Radiotherapy uses radiation to damage cancer cells so ...
A Kindler syndrome-associated squamous cell carcinoma treated with radiotherapy.
Caldeira, Ademar; Trinca, William Correia; Flores, Thais Pires; Costa, Andrea Barleze; Brito, Claudio de Sá; Weigert, Karen Loureiro; Matos, Maryana Schwartzhaupt; Nicolini, Carmela; Obst, Fernando Mariano
2016-01-01
Kindler syndrome1, 2 is a genetic disorder mainly characterized by increased skin fragility and photosensitivity,3, 4 making the use of treatments based on radiation difficult or even prohibited. Thus, cases reporting Kindler syndrome patients treated with radiotherapy are rare. In this study, we report clinical outcomes and care provided for a rare case of a Kindler syndrome patient submitted to radiotherapy. Diagnosed with squamous cell carcinoma involving the buccal mucosa, the patient was exclusively treated with radiotherapy, with 70 Gy delivered on the PTV with the Volumetric Modulated Arc technique. The patient's reaction regarding control of the lesion is relevant compared to patients not affected by the syndrome. We noticed acute reactions of the skin and buccal mucosa after few radiotherapy sessions, followed by a fast reduction in the tumor volume. The efficacy of radiotherapy along with multidisciplinary actions allowed treatment continuity, leading to a complete control of the lesion and life quality improvement and showed that the use of radiotherapy on Kindler syndrome patients is possible.
Radiotherapy for breast cancer: The predictable consequences of an unmet need.
Rodin, Danielle; Knaul, Felicia M; Lui, Tracey Y; Gospodarowicz, Mary
2016-10-01
Radiotherapy has had a transformative impact on the treatment of breast cancer, but is unavailable to the majority of breast cancer patients in low- and middle-income countries. In these settings, where many women present with advanced disease at an age when they are often the primary caregiver for their families, the lack of access to radiotherapy is particularly devastating. Until recently, this disparity has been largely neglected in the medical literature and it had been difficult to convince governments, industry, and policymakers of the importance of investing in radiotherapy, as well as broader cancer control strategies, in low-resource settings. The Lancet Radiotherapy Commission report published in 2015 challenged many assumptions about the affordability of radiotherapy treatment. Data from the Commission is presented here to support radiotherapy investment for breast cancer and discuss how the morbidity and premature mortality among adult women caused by breast cancer has a huge detrimental effect on both the health sector and the economy. Copyright © 2016. Published by Elsevier Ltd.
SU-F-R-01: Preclinical Radioimmunogenomics Study to Design Personalized Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdollahi, H
2016-06-15
Purpose: Radiogenomics is an active area of research to find clinical correlation between genomics and radiotherapy outcomes. In this era, many different biological issues should be taken into account. In this study we aimed to introduce “Radioimmunogenomics” as a new approach to study immunogetics issue regard to radiotherapy induced clinical manifestations. Methods: We studied different immunological pathways and signaling molecules which underling radiation response of normal and malignant tissues. In the other hand, we found many genes and proteins are responsible to radiation effects on biological tissues. We defined a theoretical framework to correlate these genes with radiotherapy outcomes asmore » TCP and NTCP biological dose tools. Results: Our theoretical results showed, high-throughput immunogenomics biomarkers can be correlated with radiotherapy outcomes. Genes regarding to inflammation, apoptosis, repair molecules and many other immunological markers can be defined as radioimmune markers to predict radiotherapy response. Conclusion: Radioimmunogenomics can be used as a new personalized radiotherapy research area to enhance treatment outcome as well as quality of life.« less
Radiotherapy in Gorlin Syndrome: Can It Be Safe and Effective in Adult Patients?
Baker, Sarah; Joseph, Kurian; Tai, Patricia
2016-01-01
Gorlin syndrome, also known as nevoid basal cell carcinoma syndrome, is a rare autosomal dominant disorder with multiple manifestations including early onset of cutaneous basal cell carcinomas (BCCs). Radiotherapy has traditionally been contraindicated due to reports of BCC induction. We describe here a patient treated successfully with radiotherapy with no tumour induction at 57 months of follow-up. A comprehensive literature review of radiotherapy outcomes in patients with Gorlin syndrome suggests radiotherapy may be a feasible treatment option for adult patients with treatment refractory lesions or surgical contraindication. © The Author(s) 2015.
Langrand-Escure, J; de Crevoisier, R; Llagostera, C; Créhange, G; Delaroche, G; Lafond, C; Bonin, C; Bideault, F; Sargos, P; Belhomme, S; Pasquier, D; Latorzeff, I; Supiot, S; Hennequin, C
2018-04-01
Considering recent phase III trials results, moderate hypofractionated radiotherapy can be considered as a standard treatment for low and intermediate risk prostate cancer management. This assessment call for a framework allowing homogeneous and reproducible practices in the different centers using this radiotherapy schedule. The French Genito-Urinary Group (GETUG) provides here recommendations for daily practice of moderate hypofractionated radiotherapy for prostate cancer, with indications, dose, fractionation, pre-treatment planning, volume of interest delineation (target volume and organs at risk) and margins, dose constraints and radiotherapy techniques. Copyright © 2018. Published by Elsevier SAS.
Omission of Breast Radiotherapy in Low-risk Luminal A Breast Cancer: Impact on Health Care Costs.
Han, K; Yap, M L; Yong, J H E; Mittmann, N; Hoch, J S; Fyles, A W; Warde, P; Gutierrez, E; Lymberiou, T; Foxcroft, S; Liu, F F
2016-09-01
The economic burden of cancer care is substantial, including steep increases in costs for breast cancer management. There is mounting evidence that women age ≥ 60 years with grade I/II T1N0 luminal A (ER/PR+, HER2- and Ki67 ≤ 13%) breast cancer have such low local recurrence rates that adjuvant breast radiotherapy might offer limited value. We aimed to determine the total savings to a publicly funded health care system should omission of radiotherapy become standard of care for these patients. The number of women aged ≥ 60 years who received adjuvant radiotherapy for T1N0 ER+ HER2- breast cancer in Ontario was obtained from the provincial cancer agency. The cost of adjuvant breast radiotherapy was estimated through activity-based costing from a public payer perspective. The total saving was calculated by multiplying the estimated number of luminal A cases that received radiotherapy by the cost of radiotherapy minus Ki-67 testing. In 2010, 748 women age ≥ 60 years underwent surgery for pT1N0 ER+ HER2- breast cancer; 539 (72%) underwent adjuvant radiotherapy, of whom 329 were estimated to be grade I/II luminal A subtype. The cost of adjuvant breast radiotherapy per case was estimated at $6135.85; the cost of Ki-67 at $114.71. This translated into an annual saving of about $2.0million if radiotherapy was omitted for all low-risk luminal A breast cancer patients in Ontario and $5.1million across Canada. There will be significant savings to the health care system should omission of radiotherapy become standard practice for women with low-risk luminal A breast cancer. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Yahya, Noorazrul; Roslan, Nurhaziqah
2018-01-08
As about 50% of cancer patients may require radiotherapy, the demand of radiotherapy as the main treatment to treat cancer is likely to rise due to rising cancer incidence. This study aims to quantify the radiotherapy demand in countries in Southeast Asia (SEA) in 2025 and 2035 using evidence-based optimal radiotherapy fractions. SEA country-specific cancer incidence by tumor site for 2015, 2025 and 2035 was extracted from the GLOBOCAN database. We utilized the optimal radiotherapy utilization rate model by Wong et al. (2016) to calculate the optimal number of fractions for all tumor sites in each SEA country. The available machines (LINAC & Co-60) were extracted from the IAEA's Directory of Radiotherapy Centres (DIRAC) from which the number of available fractions was calculated. The incidence of cancers in SEA countries are expected to be 1.1 mil cases (2025) and 1.4 mil (2035) compared to 0.9 mil (2015). The number of radiotherapy fractions needed in 2025 and 2035 are 11.1 and 14.1 mil, respectively, compared to 7.6 mil in 2015. In 2015, the radiotherapy fulfillment rate (RFR; required fractions/available fractions) varied between countries with Brunei, Singapore and Malaysia are highest (RFR > 1.0 - available fractions > required fractions), whereas Cambodia, Indonesia, Laos, Myanmar, Philippines, Timor-Leste and Vietnam have RFR < 0.5. RFR is correlated to GDP per capita (ρ = 0.73, P = 0.01). To allow RFR ≥1 in 2025 and 2035, another 866 and 1177 machines are required, respectively. The number are lower if longer running hours are implemented. With the optimal number of radiotherapy fractions, estimation for number of machines required can be obtained which will guide acquisition of machines in SEA countries. RFR is low with access varied based on the economic status. © 2018 John Wiley & Sons Australia, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rades, Dirk; Department of Radiation Oncology, University Medical Center Hamburg-Eppendorf, Hamburg; Stoehr, Monika
2008-03-15
Purpose: Stage IV head and neck cancer patients carry a poor prognosis. Clear understanding of prognostic factors can help to optimize care for the individual patient. This study investigated 11 potential prognostic factors including pre-radiotherapy hemoglobin level and interruptions during radiotherapy for overall survival (OS), metastases-free survival (MFS), and locoregional control (LC) after radiochemotherapy. Methods and Materials: Eleven factors were investigated in 153 patients receiving radiochemotherapy for Stage IV squamous cell head and neck cancer: age, gender, Karnofsky performance score (KPS), tumor site, grading, T stage, N stage, pre-radiotherapy hemoglobin level, surgery, chemotherapy type, and interruptions during radiotherapy >1 week.more » Results: On multivariate analysis, improved OS was associated with KPS 90-100 (relative risk [RR], 2.36; 95% confidence interval [CI], 1.20-4.93; p = .012), hemoglobin {>=}12 g/dL (RR, 1.88; 95% CI, 1.01-3.53; p = .048), and no radiotherapy interruptions (RR, 2.59; 95% CI, 1.15-5.78; p = .021). Improved LC was significantly associated with lower T stage (RR, 2.17; 95% CI, 1.16-4.63; p = .013), hemoglobin {>=}12 g/dL (RR, 4.12; 95% CI, 1.92-9.09; p < .001), surgery (RR, 2.67; 95% CI, 1.28-5.88; p = .008), and no radiotherapy interruptions (RR, 3.32; 95% CI, 1.26-8.79; p = .015). Improved MFS was associated with KPS 90-100 (RR, 3.41; 95% CI, 1.46-8.85; p = .012). Conclusions: Significant predictors for outcome in Stage IV head and neck cancer were performance status, stage, surgery, pre-radiotherapy hemoglobin level, and interruptions during radiotherapy >1 week. It appears important to avoid anemia and radiotherapy interruptions to achieve the best treatment results.« less
The Benefits of Providing External Beam Radiotherapy in Low- and Middle-income Countries.
Yap, M L; Hanna, T P; Shafiq, J; Ferlay, J; Bray, F; Delaney, G P; Barton, M
2017-02-01
More than half of all cancer diagnoses worldwide occur in low- and middle-income countries (LMICs) and the incidence is projected to rise substantially within the next 20 years. Radiotherapy is a vital, cost-effective treatment for cancer; yet there is currently a huge deficit in radiotherapy services within these countries. The aim of this study was to estimate the potential outcome benefits if external beam radiotherapy was provided to all patients requiring such treatment in LMICs, according to the current evidence-based guidelines. Projected estimates of these benefits were calculated to 2035, obtained by applying the previously published Collaboration for Cancer Outcomes, Research and Evaluation (CCORE) demand and outcome benefit estimates to cancer incidence and projection data from the GLOBOCAN 2012 data. The estimated optimal radiotherapy utilisation rate for all LMICs was 50%. There were about 4.0 million cancer patients in LMICs who required radiotherapy in 2012. This number is projected to increase by 78% by 2035, a far steeper increase than the 38% increase expected in high-income countries. National radiotherapy benefits varied widely, and were influenced by case mix. The 5 year population local control and survival benefits for all LMICs, if radiotherapy was delivered according to guidelines, were estimated to be 9.6% and 4.4%, respectively, compared with no radiotherapy use. This equates to about 1.3 million patients who would derive a local control benefit in 2035, whereas over 615 000 patients would derive a survival benefit if the demand for radiotherapy in LMICs was met. The potential outcome benefits were found to be higher in LMICs. These results further highlight the urgent need to reduce the gap between the supply of, and demand for, radiotherapy in LMICs. We must attempt to address this 'silent crisis' as a matter of priority and the approach must consider the complex societal challenges unique to LMICs. Copyright © 2016 The Royal College of Radiologists. All rights reserved.
Datta, Niloy R; Rogers, Susanne; Ordóñez, Silvia Gómez; Puric, Emsad; Bodis, Stephan
2016-01-01
A systematic review and meta-analysis was conducted to evaluate the outcome of controlled clinical trials in head and neck cancers (HNCs) using hyperthermia and radiotherapy versus radiotherapy alone. A total of 498 abstracts were screened from four databases and hand searched as per the PRISMA guidelines. Only two-arm studies treating HNCs with either radiotherapy alone, or hyperthermia and radiotherapy without concurrent chemotherapy or surgery were considered. The evaluated end point was complete response (CR). Following a detailed screening of the titles, abstracts and full text papers, six articles fulfilling the above eligibility criteria were considered. In total 451 clinical cases from six studies were included in the meta-analysis. Five of six trials were randomised. The overall CR with radiotherapy alone was 39.6% (92/232) and varied between 31.3% and 46.9% across the six trials. With thermoradiotherapy, the overall CR reported was 62.5% (137/219), (range 33.9-83.3%). The odds ratio was 2.92 (95% CI: 1.58-5.42, p = 0.001); the risk ratio was 1.61 (95% CI: 1.32-1.97, p < 0.0001) and the risk difference was 0.25 (95% CI: 0.12-0.39, p < 0.0001), all in favour of combined treatment with hyperthermia and radiotherapy over radiotherapy alone. Acute and late grade III/IV toxicities were reported to be similar in both the groups. Hyperthermia along with radiotherapy enhances the likelihood of CR in HNCs by around 25% compared to radiotherapy alone with no significant additional acute and late morbidities. This level I evidence should justify the integration of hyperthermia into the multimodality therapy of HNCs.
Thomas, Francis; Holly, Jeff M P; Persad, Rajendra; Bahl, Amit; Perks, Claire M
2011-08-01
To assess the influence of epigallocatechin-3-gallate (EGCG) on the efficacy of ionizing radiation on prostate cancer cells because of the increased use of dietary interventions, especially by patients with prostate cancer. Radiotherapy is used to treat localized prostate cancer. Some people consume green tea (EGCG) as a chemopreventive agent against prostate cancer. Green tea can act as an antioxidant and induce superoxide dismutase enzymes, which could scavenge the free oxygen radicals generated by radiotherapy. Prostate cancer cell line DU145 cells were treated with EGCG or radiotherapy, or both. Cell death was assessed using trypan blue cell counting, and apoptosis was confirmed by assessing poly (adenosine phosphate ribose) polymerase cleavage. The antioxidant potential was assessed using Western immunoblotting for manganese superoxide dismutase and copper zinc superoxide dismutase enzymes. Radiotherapy was delivered using a linear accelerator. Cell cycle analysis was performed using flow cytometry. Radiotherapy at 3.5 Gy induced a 5.9-fold increase in apoptosis of DU145 cells. Subapoptotic doses of EGCG (1.5-7.5 μM) significantly reduced ionizing radiation-induced apoptosis (P < .001), with the inhibitory effect of EGCG on ionizing radiation being most effective when added 30 minutes before radiotherapy (P < .001). In addition, when radiotherapy and EGCG were used together, an approximate 1.5-fold increase in manganese superoxide dismutase levels was seen compared with the control and a 2-fold increase compared with radiotherapy alone. Radiotherapy is effective in inducing apoptosis in DU145 cells, but its effect was significantly reduced in the presence of EGCG, and this was associated with an increase in the induction of manganese superoxide dismutase. Copyright © 2011 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pradier, Olivier; Christiansen, Hans; Schmidberger, Heinz
Purpose: To evaluate the efficacy of an adjuvant radiotherapy after transoral laser microsurgery for advanced squamous cell carcinoma of the head and neck and to show that a less invasive surgery with organ preservation in combination with radiotherapy is an alternative to a radical treatment. Patients and Methods: Between 1987 and 2000, 208 patients with advanced squamous cell carcinoma of the head and neck were treated with postoperative radiotherapy after surgical CO{sub 2} laser resection. Primary sites included oral cavity, 38; oropharynx, 88; larynx, 36; hypopharynx, 46. Disease stages were as follows: Stage III, 40 patients; Stage IV, 168 patients.more » Before 1994, the treatment consisted of a split-course radiotherapy with carboplatinum (Treatment A). After 1994, the patients received a conventional radiotherapy (Treatment B). Results: Patients had 5-year locoregional control and disease-specific survival (DSS) rates of 68% and 48%, respectively. The 5-year DSS was 70% and 44% for Stages III and IV, respectively (p = 0.00127). Patients treated with a hemoglobin level greater or equal to 13.5 g/dL before radiotherapy had a 5-year DSS of 55% as compared with 39% for patients treated with a hemoglobin level greater than 13.5 g/dL (p = 0.0054). Conclusion: In this series of patients with advanced head-and-neck tumors, transoral laser surgery in combination with adjuvant radiotherapy resulted in locoregional control and DSS rates similar to those reported for radical surgery followed by radiotherapy. Treatment B has clearly been superior to Treatment A. A further improvement of our treatment regimen might be expected by the combination of adjuvant radiotherapy with concomitant platinum-based chemotherapy.« less
Radiotherapy for ductal carcinoma in situ and risk of second non-breast cancers.
Withrow, Diana R; Morton, Lindsay M; Curtis, Rochelle E; Schonfeld, Sara J; Berrington de González, Amy
2017-11-01
Radiotherapy for ductal carcinoma (DCIS) is increasing, but the risks and benefits of the treatment remain uncertain. We aimed to investigate the relationship between radiotherapy for DCIS and risk of second non-breast cancers in a large US cohort. We conducted a retrospective cohort study of 52,556 women in 12 U.S. population-based cancer registries diagnosed with first primary DCIS during 1992-2008 at age 25-79 years. We estimated relative risks (RRs), attributable risks (AR), and excess absolute risks (EAR) of second non-breast cancers associated with radiotherapy using Poisson regression adjusted for age at year of diagnosis, grade, hormonal therapy (yes/no or unknown), and time since diagnosis. Approximately half of the women (46.3%) received radiotherapy. Radiotherapy was associated with an increased risk of all second non-breast cancers combined [RR 1.17, 95% confidence interval (CI) 1.08-1.28] and all in-field, radiation-related second cancers combined (RR 1.37, 95% CI 1.15-1.63), driven by second lung cancers (RR 1.33, 95% CI 1.10-1.60) and non-CLL leukemia (RR 1.71, 95% CI 1.02-2.86). The estimated cumulative excess risk of all second non-breast cancers was 0.8% by 15 years after DCIS diagnosis. Radiotherapy was associated with an increased risk of second non-breast cancers. The specific excess of cancers at sites likely in/near the radiotherapy field suggests the findings are unlikely due exclusively to confounding, but further research into factors related to receipt of radiotherapy is needed. Our risk estimates can be used to help assess the balance of the risks and benefits of radiotherapy for DCIS and to inform clinical practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiinoki, T; Hanazawa, H; Shibuya, K
Purpose: The respirato ry gating system combined the TrueBeam and a new real-time tumor-tracking radiotherapy system (RTRT) was installed. The RTRT system consists of two x-ray tubes and color image intensifiers. Using fluoroscopic images, the fiducial marker which was implanted near the tumor was tracked and was used as the internal surrogate for respiratory gating. The purposes of this study was to develop the verification technique of the respiratory gating with the new RTRT using cine electronic portal image device images (EPIDs) of TrueBeam and log files of the RTRT. Methods: A patient who underwent respiratory gated SBRT of themore » lung using the RTRT were enrolled in this study. For a patient, the log files of three-dimensional coordinate of fiducial marker used as an internal surrogate were acquired using the RTRT. Simultaneously, the cine EPIDs were acquired during respiratory gated radiotherapy. The data acquisition was performed for one field at five sessions during the course of SBRT. The residual motion errors were calculated using the log files (E{sub log}). The fiducial marker used as an internal surrogate into the cine EPIDs was automatically extracted by in-house software based on the template-matching algorithm. The differences between the the marker positions of cine EPIDs and digitally reconstructed radiograph were calculated (E{sub EPID}). Results: Marker detection on EPID using in-house software was influenced by low image contrast. For one field during the course of SBRT, the respiratory gating using the RTRT showed the mean ± S.D. of 95{sup th} percentile E{sub EPID} were 1.3 ± 0.3 mm,1.1 ± 0.5 mm,and those of E{sub log} were 1.5 ± 0.2 mm, 1.1 ± 0.2 mm in LR and SI directions, respectively. Conclusion: We have developed the verification method of respiratory gating combined TrueBeam and new real-time tumor-tracking radiotherapy system using EPIDs and log files.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bekelman, Justin E., E-mail: bekelman@uphs.upenn.edu; Deye, James A.; Vikram, Bhadrasain
2012-07-01
Purpose: In the context of national calls for reorganizing cancer clinical trials, the National Cancer Institute sponsored a 2-day workshop to examine challenges and opportunities for optimizing radiotherapy quality assurance (QA) in clinical trial design. Methods and Materials: Participants reviewed the current processes of clinical trial QA and noted the QA challenges presented by advanced technologies. The lessons learned from the radiotherapy QA programs of recent trials were discussed in detail. Four potential opportunities for optimizing radiotherapy QA were explored, including the use of normal tissue toxicity and tumor control metrics, biomarkers of radiation toxicity, new radiotherapy modalities such asmore » proton beam therapy, and the international harmonization of clinical trial QA. Results: Four recommendations were made: (1) to develop a tiered (and more efficient) system for radiotherapy QA and tailor the intensity of QA to the clinical trial objectives (tiers include general credentialing, trial-specific credentialing, and individual case review); (2) to establish a case QA repository; (3) to develop an evidence base for clinical trial QA and introduce innovative prospective trial designs to evaluate radiotherapy QA in clinical trials; and (4) to explore the feasibility of consolidating clinical trial QA in the United States. Conclusion: Radiotherapy QA can affect clinical trial accrual, cost, outcomes, and generalizability. To achieve maximum benefit, QA programs must become more efficient and evidence-based.« less
Children Undergoing Radiotherapy: Swedish Parents’ Experiences and Suggestions for Improvement
Mullaney, Tara; Nilsson, Kristina; Wickart-Johansson, Gun; Svärd, Anna-Maja; Nyholm, Tufve; Lindh, Jack; Lindh, Viveca
2015-01-01
Approximately 300 children, from 0 to 18 years old, are diagnosed with cancer in Sweden every year. Of these children, 80–90 of them undergo radiotherapy treatment for their cancer. Although radiotherapy is an encounter with advanced technology, few studies have investigated the child’s and the parent’s view of the procedure. As part of an ongoing multicenter study aimed to improve patient preparation and the care environment in pediatric radiotherapy, this article reports the findings from interviews with parents at baseline. The aim of the present study was twofold: to describe parents’ experience when their child undergoes radiotherapy treatment, and to report parents’ suggestions for improvements during radiotherapy for their children. Sixteen mothers and sixteen fathers of children between 2–16 years old with various cancer diagnoses were interviewed. Data were analyzed using content analysis. The findings showed that cancer and treatment turns people’s lives upside down, affecting the entire family. Further, the parents experience the child’s suffering and must cope with intense feelings. Radiotherapy treatment includes preparation by skilled and empathetic staff. The parents gradually find that they can deal with the process; and lastly, parents have suggestions for improvements during the radiotherapy treatment. An overarching theme emerged: that despair gradually turns to a sense of security, with a sustained focus on and close interaction with the child. In conclusion, an extreme burden was experienced around the start of radiotherapy, though parents gradually coped with the process. PMID:26509449
Bekelman, Justin E; Deye, James A; Vikram, Bhadrasain; Bentzen, Soren M; Bruner, Deborah; Curran, Walter J; Dignam, James; Efstathiou, Jason A; FitzGerald, T J; Hurkmans, Coen; Ibbott, Geoffrey S; Lee, J Jack; Merchant, Thomas E; Michalski, Jeff; Palta, Jatinder R; Simon, Richard; Ten Haken, Randal K; Timmerman, Robert; Tunis, Sean; Coleman, C Norman; Purdy, James
2012-07-01
In the context of national calls for reorganizing cancer clinical trials, the National Cancer Institute sponsored a 2-day workshop to examine challenges and opportunities for optimizing radiotherapy quality assurance (QA) in clinical trial design. Participants reviewed the current processes of clinical trial QA and noted the QA challenges presented by advanced technologies. The lessons learned from the radiotherapy QA programs of recent trials were discussed in detail. Four potential opportunities for optimizing radiotherapy QA were explored, including the use of normal tissue toxicity and tumor control metrics, biomarkers of radiation toxicity, new radiotherapy modalities such as proton beam therapy, and the international harmonization of clinical trial QA. Four recommendations were made: (1) to develop a tiered (and more efficient) system for radiotherapy QA and tailor the intensity of QA to the clinical trial objectives (tiers include general credentialing, trial-specific credentialing, and individual case review); (2) to establish a case QA repository; (3) to develop an evidence base for clinical trial QA and introduce innovative prospective trial designs to evaluate radiotherapy QA in clinical trials; and (4) to explore the feasibility of consolidating clinical trial QA in the United States. Radiotherapy QA can affect clinical trial accrual, cost, outcomes, and generalizability. To achieve maximum benefit, QA programs must become more efficient and evidence-based. Copyright © 2012 Elsevier Inc. All rights reserved.
Ohkubo, Yu; Saito, Yoshihiro; Ushijima, Hiroki; Onishi, Masahiro; Kazumoto, Tomoko; Saitoh, Jun-Ichi; Kubota, Nobuko; Kobayashi, Hirofumi; Maseki, Nobuo; Nishimura, Yu; Kurosumi, Masafumi
2017-07-01
This study aimed to assess the long-term outcomes of radiotherapy in patients with localized gastric mucosa-associated lymphoid tissue (MALT) lymphoma. Twenty-seven patients with Stage I gastric MALT lymphoma were treated with radiotherapy from 1999 to 2010. The median age was 65 years (range: 31-84). Fifteen patients were Helicobacter pylori-negative. Thirteen patients were treated with definitive radiotherapy alone. The other 14 patients who had refractory or residual disease following a prior treatment received salvage radiotherapy. The median dose of the radiotherapy was 30 Gy in 20 fractions (range: 30-39.5 Gy). The median follow-up period was 121 months (range: 8-176 months). The 5- and 10-year overall survival rates for all patients were 92% and 87%, respectively. No patients died from MALT lymphoma. Three patients died of other diseases at 8, 33 and 74 months after radiotherapy (myocardial infarction, pneumonia and hepatocellular carcinoma, respectively). No cases of local recurrence were observed during the follow-up period. There were no serious late gastric, liver or kidney complications during a median follow-up period of over 10 years. Two patients remain alive with distant metastases: a lung metastasis and an abdominal lymph node metastasis at 104 months and 21 months after radiotherapy, respectively. Excellent long-term local control was observed in patients with localized gastric MALT lymphoma after radiotherapy. However, lifelong follow-up should be conducted to detect cases of late recurrence, especially distant metastases. © Oxford University Press 2017.
Loos, G; Moreau, J; Miroir, J; Benhaïm, C; Biau, J; Caillé, C; Bellière, A; Lapeyre, M
2013-10-01
The various image-guided radiotherapy techniques raise the question of how to achieve the control of patient positioning before irradiation session and sharing of tasks between radiation oncologists and radiotherapy technicians. We have put in place procedures and operating methods to make a partial delegation of tasks to radiotherapy technicians and secure the process in three situations: control by orthogonal kV imaging (kV-kV) of bony landmarks, control by kV-kV imaging of intraprostatic fiducial goldmarkers and control by cone beam CT (CBCT) imaging for prostate cancer. Significant medical overtime is required to control these three IGRT techniques. Because of their competence in imaging, these daily controls can be delegated to radiotherapy technicians. However, to secure the process, initial training and regular evaluation are essential. The analysis of the comparison of the use of kV/kV on bone structures allowed us to achieve a partial delegation of control to radiotherapy technicians. Controlling the positioning of the prostate through the use and automatic registration of fiducial goldmarkers allows better tracking of the prostate and can be easily delegated to radiotherapy technicians. The analysis of the use of daily cone beam CT for patients treated with intensity modulated irradiation is underway, and a comparison of practices between radiotherapy technicians and radiation oncologists is ongoing to know if a partial delegation of this control is possible. Copyright © 2013. Published by Elsevier SAS.
Paragangliomas: presentation and management by radiotherapy at the Prince of Wales Hospital.
Smee, Robert I; Jayasekara, Jayana; Williams, Janet R; Hanna, Claire
2015-04-01
Paragangliomas are commonly treated with surgery, while radiotherapy is reserved for those that are inoperable or have relapsed. However, this retrospective study aims to determine whether radiotherapy is a viable initial treatment for paragangliomas. Of 73 tumours researched, 44 were diagnosed and treated from January 1967 to December 2012 at the Radiation Oncology Department at the Prince of Wales Hospital and thus were eligible for analysis. Median follow-up time was 3.5 years with a range of 1 to 40 years. Thirty-four tumours were treated with radiotherapy only, and 10 tumours were treated with both surgical resection and radiotherapy. Local control and cause-specific survival were the primary end points measured. Five-year local control rate for the population of 44 lesions was 89%; it was 100% in the group treated by radiotherapy alone, but only 50% in the group treated by surgery followed by radiotherapy, with radiation used for salvage. The difference in control rates between these two subset groups was found to be statistically significant (P < 0.001). Cause-specific survival rates for this eligible population at 5 and 10 years were 98% and 90%, respectively. After initial radiotherapy, 4 patients had improved cranial nerve function, there was clinical improvement in tinnitus, and one new cranial nerve deficit developed where a high dose was used. Radiotherapy has high local control rates and few complications. The local control and complication rates compare favourably to surgery. © 2014 The Royal Australian and New Zealand College of Radiologists.
Shaverdian, Narek; Lisberg, Aaron E; Bornazyan, Krikor; Veruttipong, Darlene; Goldman, Jonathan W; Formenti, Silvia C; Garon, Edward B; Lee, Percy
2017-07-01
Preclinical studies have found radiotherapy enhances antitumour immune responses. We aimed to assess disease control and pulmonary toxicity in patients who previously received radiotherapy for non-small-cell lung cancer (NSCLC) before receiving pembrolizumab. We assessed patients with advanced NSCLC treated on the phase 1 KEYNOTE-001 trial at a single institution (University of California, Los Angeles, CA, USA). Patients were aged 18 years or older, had an Eastern Cooperative Oncology Group performance status of 1 or less, had adequate organ function, and no history of pneumonitis. Patients received pembrolizumab at a dose of either 2 mg/kg of bodyweight or 10 mg/kg every 3 weeks, or 10 mg/kg every 2 weeks, until disease progression, unacceptable toxicity, or other protocol-defined reasons for discontinuation. Disease response and pulmonary toxicity were prospectively assessed by Immune-related Response Criteria and Common Terminology Criteria for Adverse Events version 4.0. The primary objective of the KEYNOTE-001 trial was to assess the safety, side-effect profile, and antitumour activity of pembrolizumab. For our secondary analysis, patients were divided into subgroups to compare patients who previously received radiotherapy with patients who had not. Our primary objective was to determine whether previous radiotherapy affected progression-free survival, overall survival, and pulmonary toxicity in the intention-to-treat population. The KEYNOTE-001 trial was registered with ClinicalTrials.gov, number NCT01295827. Between May 22, 2012, and July 11, 2014, 98 patients were enrolled and received their first cycle of pembrolizumab. One patient was lost to follow-up. 42 (43%) of 97 patients had previously received any radiotherapy for the treatment of NSCLC before the first cycle of pembrolizumab. 38 (39%) of 97 patients received extracranial radiotherapy and 24 (25%) of 97 patients received thoracic radiotherapy. Median follow-up for surviving patients was 32·5 months (IQR 29·8-34·1). Progression-free survival with pembrolizumab was significantly longer in patients who previously received any radiotherapy than in patients without previous radiotherapy (hazard ratio [HR] 0·56 [95% CI 0·34-0·91], p=0·019; median progression-free survival 4·4 months [95% CI 2·1-8·6] vs 2·1 months [1·6-2·3]) and for patients who previously received extracranial radiotherapy compared with those without previous extracranial radiotherapy (HR 0·50 [0·30-0·84], p=0·0084; median progression-free survival 6·3 months [95% CI 2·1-10·4] vs 2·0 months [1·8-2·1]). Overall survival with pembrolizumab was significantly longer in patients who previously received any radiotherapy than in patients without previous radiotherapy (HR 0·58 [95% CI 0·36-0·94], p=0·026; median overall survival 10·7 months [95% CI 6·5-18·9] vs 5·3 months [2·7-7·7]) and for patients who previously received extracranial radiotherapy compared with those without previous extracranial radiotherapy (0·59 [95% CI 0·36-0·96], p=0·034; median overall survival 11·6 months [95% CI 6·5-20·5] vs 5·3 months [3·0-8·5]). 15 (63%) of 24 patients who had previously received thoracic radiotherapy had any recorded pulmonary toxicity versus 29 (40%) of 73 patients with no previous thoracic radiotherapy. Three (13%) patients with previous thoracic radiotherapy had treatment-related pulmonary toxicity compared with one (1%) of those without; frequency of grade 3 or worse treatment-related pulmonary toxicities was similar (one patient in each group). Our data suggest that previous treatment with radiotherapy in patients with advanced NSCLC results in longer progression-free survival and overall survival with pembrolizumab treatment than that seen in patients who did not have previous radiotherapy, with an acceptable safety profile. Further clinical trials investigating this combination are needed to determine the optimal treatment strategy for patients with advanced NSCLC. US National Institutes of Health. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sci-Thur PM – Colourful Interactions: Highlights 05: Opal–the Oncology Patient Application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joseph, Ackeem; Herrera, David; Kildea, John
We describe Opal (Oncology portal and application), the mobile phone app and patient portal that we have developed and are deploying for Radiation Oncology patients at our cancer centre. Opal is a novel tool to empower patients with their own personal medical data, including appointment schedules, consultation notes, test results, radiotherapy treatment planning information and wait time management. Furthermore, due to its integration with our electronic medical record and treatment planning database, Opal will allow us to collect patient reported outcomes from consenting patients and link them directly with dose volume histograms and other treatment data.
Shielding and Radiation Protection in Ion Beam Therapy Facilities
NASA Astrophysics Data System (ADS)
Wroe, Andrew J.; Rightnar, Steven
Radiation protection is a key aspect of any radiotherapy (RT) department and is made even more complex in ion beam therapy (IBT) by the large facility size, secondary particle spectra and intricate installation of these centers. In IBT, large and complex radiation producing devices are used and made available to the public for treatment. It is thus the responsibility of the facility to put in place measures to protect not only the patient but also the general public, occupationally and nonoccupationally exposed personnel working within the facility, and electronics installed within the department to ensure maximum safety while delivering maximum up-time.
Robatjazi, Mostafa; Baghani, Hamid Reza; Mahdavic, Seied Rabi; Felici, Giuseppe
2018-05-01
A shielding disk is used for IOERT procedures to absorb radiation behind the target and protect underlying healthy tissues. Setup variation of shielding disk can affect the corresponding in-vivo dose distribution. In this study, the changes of dosimetric parameters due to the disk setup variations is evaluated using EGSnrc Monte Carlo (MC) code. The results can help treatment team to decide about the level of accuracy in the setup procedure and delivered dose to the target volume during IOERT. Copyright © 2018 Elsevier Ltd. All rights reserved.
Intraoperative radiotherapy using a mobile electron LINAC: a retroperitoneal sarcoma case.
Beddar, A Sam; Krishnan, Sunil
2005-01-01
The advent of mobile LINACs for use in intraoperative radiation therapy (IORT) promises to make IORT more accessible than before and easier to deliver to patients undergoing surgery. Although mobile IORT systems have been available since 1999, few treatment centers currently use them. Here, we present the case of a typical patient undergoing IORT for retroperitoneal sarcoma to show how easy these mobile systems are to use and how adaptable they are within the operating room (OR) environment. We also discuss the roles and coordination of multidisciplinary team members during IORT and the feasibility of using mobile LINACs for IORT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joseph, A.; Seuntjens, J.; Parker, W.
We describe development of automated, web-based, electronic health record (EHR) auditing software for use within our paperless radiation oncology clinic. By facilitating access to multiple databases within the clinic, each patient's EHR is audited prior to treatment, regularly during treatment, and post treatment. Anomalies such as missing documentation, non-compliant workflow and treatment parameters that differ significantly from the norm may be monitored, flagged and brought to the attention of clinicians. By determining historical trends using existing patient data and by comparing new patient data with the historical, we expect our software to provide a measurable improvement in the quality ofmore » radiotherapy at our centre.« less
Ethylene-vinyl acetate foam as a new lung substitute in radiotherapy.
Marqués, Enrique; Mancha, Pedro J
2018-04-01
The purpose of this study was to evaluate ethylene-vinyl acetate (EVA) foam as a new lung substitute in radiotherapy and to study its physical and dosimetric characteristics. We calculated the ideal vinyl acetate (VA) content of EVA foam sheets to mimic the physical and dosimetric characteristics of the ICRU lung tissue. We also computed the water-to-medium mass collision stopping power ratios, mass attenuation coefficients, CT numbers, effective atomic numbers and electron densities for: ICRU lung tissue, the RANDO commercial phantom, scaled WATER and EVA foam sheets with varying VA contents in a range between the minimum and maximum values supplied by the manufacturer. For all these substitutes, we simulated percent depth-dose curves with EGSnrc Monte Carlo (MC PDDs) in a water-lung substitute-water slab phantom expressed as dose-to-medium and dose-to-water for 3 × 3- and 10 × 10-cm 2 field sizes. PDD for the 10 × 10-cm 2 field size was also calculated with the MultiGrid Superposition algorithm (MGS PDD) for a relative electron density to water ratio of 0.26. The latter was compared with the MC PDDs in dose-to-water for scaled WATER and EVA foam sheets with the VA content that was most similar to the calculated ideal content that is physically achievable in practice. We calculated an ideal VA content of 55%; however, the maximum physically achievable content with current manufacturing techniques is 40%. The physical characteristics of the EVA foam sheets with a VA content of 40% (EVA40) are very close to those of the ICRU lung reference. The physical densities of the EVA40 foam sheets ranged from 0.030 to 0.965 g/cm 3 , almost covering the entire physical density range of the inflated/deflated lung (0.260-1.050 g/cm 3 ). Its mass attenuation coefficient at the effective energy of a 6-MV photon beam agrees within 0.8% of the ICRU reference value, and its CT number agrees within 6 HU. The effective atomic number for EVA40 varies by less than 0.42 of the ICRU value, and its effective electron density is within 0.9%. PDDs expressed in dose-to-medium and dose-to-water agree with the ICRU curve within 2% in all regions. PDDs calculated with both MC and MGS were within 1.5%. The EVA40 is an excellent cork-like lung substitute for radiotherapy applications. From a sole material used in footwear, it is possible to obtain a lung substitute that mimics the physical and dosimetric characteristics of ICRU lung tissue even better than the RANDO commercial phantom. © 2018 American Association of Physicists in Medicine.
Harata, Naoki; Yoshida, Katsuya; Oota, Sayako; Fujii, Hayahiko; Isogai, Jun; Yoshimura, Ryoichi
2016-01-01
We retrospectively investigated changes of (18)F-fluorodeocyglucose ((18)F-FDG) uptake in the spinal cord, inside and outside the radiation fields, in patients with esophageal cancer before and after conventional dose radiotherapy. A total of 17 consecutive patients with esophageal cancer (16 males, one female; age 50-83 years, mean 67.0 years), who underwent conventional dose radiotherapy and (18)F-FDG PET/CT before and 5.1 months (range 1.6-8.6 months) after the radiotherapy, were retrospectively evaluated. Sixteen patients had esophageal cancer and one patient had esophageal metastasis from thyroid cancer. Mean standardized uptake values (SUVmean) of the cervical, thoracic (inside and outside the radiation fields) and lumbar spinal cord were measured. SUVmean of the thoracic spinal cord inside the radiation field was decreased significantly after radiotherapy compared to those before radiotherapy (p < 0.001). SUVmean of the cervical spinal cord showed the same trend but it was not statistically significant (p = 0.051). SUVmean of the thoracic spinal cord outside the radiation field and the lumbar spinal cord did not differ significantly before and after the radiotherapy (p = 0.146 and p = 0.701, respectively). The results suggest that glucose metabolism of the spinal cord is decreased in esophageal cancer patients after conventional dose radiotherapy.
Quality of radiotherapy services in post-Soviet countries: An IAEA survey.
Rosenblatt, Eduardo; Fidarova, Elena; Ghosh, Sunita; Zubizarreta, Eduardo; Unterkirhere, Olga; Semikoz, Natalia; Sinaika, Valery; Kim, Viktor; Karamyan, Nerses; Isayev, Isa; Akbarov, Kamal; Lomidze, Darejan; Bondareva, Oksana; Tuzlucov, Piotr; Zardodkhonova, Manzura; Tkachev, Sergey; Kislyakova, Marina; Alimov, Jamshid; Pidlubna, Tetiana; Barton, Michael; Mackillop, William
2018-04-25
The quality of radiotherapy services in post-Soviet countries has not yet been studied following a formal methodology. The IAEA conducted a survey using two sets of validated radiation oncology quality indicators (ROIs). Eleven post-Soviet countries were assessed. A coordinator was designated for each country and acted as the liaison between the country and the IAEA. The methodology was a one-time cross-sectional survey using a 58-question tool in Russian. The questionnaire was based on two validated sets of ROIs: for radiotherapy centres, the indicators proposed by Cionini et al., and for data at the country level, the Australasian ROIs. The overall response ratio was 66.3%, but for the Russian Federation, it was 24%. Data were updated on radiotherapy infrastructure and equipment. 256 radiotherapy centres are operating 275 linear accelerators and 337 Cobalt-60 units. 61% of teletherapy machines are older than ten years. Analysis of ROIs revealed significant differences between these countries and radiotherapy practices in the West. Naming, task profile and education programmes of radiotherapy professionals are different than in the West. Most countries need modernization of their radiotherapy infrastructure coupled with adequate staffing numbers and updated education programmes focusing on evidence-based medicine, quality, and safety. Copyright © 2018 Elsevier B.V. All rights reserved.
Bedini, Nice; Cicchetti, Alessandro; Palorini, Federica; Magnani, Tiziana; Zuco, Valentina; Pennati, Marzia; Campi, Elisa; Allavena, Paola; Pesce, Samantha; Villa, Sergio; Avuzzi, Barbara; Morlino, Sara; Visentin, Maria Emanuela; Zaffaroni, Nadia; Valdagni, Riccardo
2018-01-01
A recent “hot topic” in prostate cancer radiotherapy is the observed association between acute/late rectal toxicity and the presence of abdominal surgery before radiotherapy. The exact mechanism is unclear. Our working hypothesis was that a previous surgery may influence plasma level of inflammatory molecules and this might result in enhanced radiosensitivity. We here present results on the feasibility of monitoring the expression of inflammatory molecules during radiotherapy. Plasma levels of a panel of soluble mediators associated with the inflammatory response were measured in prostate cancer patients undergoing radical radiotherapy. We measured 3 cytokines (IL-1b, IL-6, and TNF alpha), 2 chemokines (CCL2 and CXCL8), and the long pentraxin PTX3. 20 patients were enrolled in this feasibility evaluation. All patients were treated with IMRT at 78 Gy. 3/20 patients reported grade 2 acute rectal toxicity, while 4/20 were scored as grade 2 late toxicity. CCL2 was the most interesting marker showing significant increase during and after radiotherapy. CCL2 levels at radiotherapy end could be modelled using linear regression including basal CCL2, age, surgery, hypertension, and use of anticoagulants. The 4 patients with late toxicity had CCL2 values at radiotherapy end above the median value. This trial is registered with ISRCTN64979094. PMID:29682101
Bedini, Nice; Cicchetti, Alessandro; Palorini, Federica; Magnani, Tiziana; Zuco, Valentina; Pennati, Marzia; Campi, Elisa; Allavena, Paola; Pesce, Samantha; Villa, Sergio; Avuzzi, Barbara; Morlino, Sara; Visentin, Maria Emanuela; Zaffaroni, Nadia; Rancati, Tiziana; Valdagni, Riccardo
2018-01-01
A recent "hot topic" in prostate cancer radiotherapy is the observed association between acute/late rectal toxicity and the presence of abdominal surgery before radiotherapy. The exact mechanism is unclear. Our working hypothesis was that a previous surgery may influence plasma level of inflammatory molecules and this might result in enhanced radiosensitivity. We here present results on the feasibility of monitoring the expression of inflammatory molecules during radiotherapy. Plasma levels of a panel of soluble mediators associated with the inflammatory response were measured in prostate cancer patients undergoing radical radiotherapy. We measured 3 cytokines (IL-1b, IL-6, and TNF alpha), 2 chemokines (CCL2 and CXCL8), and the long pentraxin PTX3. 20 patients were enrolled in this feasibility evaluation. All patients were treated with IMRT at 78 Gy. 3/20 patients reported grade 2 acute rectal toxicity, while 4/20 were scored as grade 2 late toxicity. CCL2 was the most interesting marker showing significant increase during and after radiotherapy. CCL2 levels at radiotherapy end could be modelled using linear regression including basal CCL2, age, surgery, hypertension, and use of anticoagulants. The 4 patients with late toxicity had CCL2 values at radiotherapy end above the median value. This trial is registered with ISRCTN64979094.
Impact of immunotherapy among patients with melanoma brain metastases managed with radiotherapy.
Stokes, William A; Binder, David C; Jones, Bernard L; Oweida, Ayman J; Liu, Arthur K; Rusthoven, Chad G; Karam, Sana D
2017-12-15
Patients with melanoma brain metastases (MBM) have been excluded from trials evaluating immunotherapy in melanoma. As such, immunotherapy's role in MBM is poorly understood, particularly in combination with radiotherapy. The National Cancer Database was queried for patients with MBM receiving brain radiotherapy. They were classified according to immunotherapy receipt. Multivariate Cox regression was performed to identify factors associated with survival. Among 1287 patients, 185 received immunotherapy. Factors associated with improved survival included younger age, academic facility, lower extracranial disease burden, stereotactic radiotherapy, chemotherapy, and immunotherapy. Adding immunotherapy to radiotherapy for MBM is associated with improved survival. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Lee, Junghoon; Carass, Aaron; Jog, Amod; Zhao, Can; Prince, Jerry L.
2017-02-01
Accurate CT synthesis, sometimes called electron density estimation, from MRI is crucial for successful MRI-based radiotherapy planning and dose computation. Existing CT synthesis methods are able to synthesize normal tissues but are unable to accurately synthesize abnormal tissues (i.e., tumor), thus providing a suboptimal solution. We propose a multiatlas- based hybrid synthesis approach that combines multi-atlas registration and patch-based synthesis to accurately synthesize both normal and abnormal tissues. Multi-parametric atlas MR images are registered to the target MR images by multi-channel deformable registration, from which the atlas CT images are deformed and fused by locally-weighted averaging using a structural similarity measure (SSIM). Synthetic MR images are also computed from the registered atlas MRIs by using the same weights used for the CT synthesis; these are compared to the target patient MRIs allowing for the assessment of the CT synthesis fidelity. Poor synthesis regions are automatically detected based on the fidelity measure and refined by a patch-based synthesis. The proposed approach was tested on brain cancer patient data, and showed a noticeable improvement for the tumor region.
A new radiotherapy surface dose detector:the MOSFET.
Butson, M J; Rozenfeld, A; Mathur, J N; Carolan, M; Wong, T P; Metcalfe, P E
1996-05-01
Radiotherapy x-ray and electron beam surface doses are accurately measurable by use of a MOS-FET detector system. The MOSFET (Metal Oxide Semiconductor Field Effect Transistor) is approximately 200-microns in diameter and consists of a 0.5-microns Al electrode on top of a 1-microns SiO2 and 300-microns Si substrate. Results for % surface dose were within +/- 2% compared to the Attix chamber and within +/- 3% of TLD extrapolation results for normally incident beams. Detectors were compared using different energies, field size, and beam modifying devices such as block trays and wedges. Percentage surface dose for 10 x 10-cm and 40 x 40-cm field size for 6-MV x rays at 100-cm SSD using the MOSFET were 16% and 42% of maximum, respectively. Factors such as its small size, immediate retrieval of results, high accuracy attainable from low applied doses, and as the MOSFET records its dose history make it a suitable in vivo dosimeter where surface and skin doses need to be determined. This can be achieved within part of the first fraction of dose (i.e., only 10 cGy is required.)
Usefulness of image morphing techniques in cancer treatment by conformal radiotherapy
NASA Astrophysics Data System (ADS)
Atoui, Hussein; Sarrut, David; Miguet, Serge
2004-05-01
Conformal radiotherapy is a cancer treatment technique, that targets high-energy X-rays to tumors with minimal exposure to surrounding healthy tissues. Irradiation ballistics is calculated based on an initial 3D Computerized Tomography (CT) scan. At every treatment session, the random positioning of the patient, compared to the reference position defined by the initial 3D CT scan, can generate treatment inaccuracies. Positioning errors potentially predispose to dangerous exposure to healthy tissues as well as insufficient irradiation to the tumor. A proposed solution would be the use of portal images generated by Electronic Portal Imaging Devices (EPID). Portal images (PI) allow a comparison with reference images retained by physicians, namely Digitally Reconstructed Radiographs (DRRs). At present, physicians must estimate patient positional errors by visual inspection. However, this may be inaccurate and consumes time. The automation of this task has been the subject of many researches. Unfortunately, the intensive use of DRRs and the high computing time required have prevented real time implementation. We are currently investigating a new method for DRR generation that calculates intermediate DRRs by 2D deformation of previously computed DRRs. We approach this investigation with the use of a morphing-based technique named mesh warping.
135La as an Auger-electron emitter for targeted internal radiotherapy
NASA Astrophysics Data System (ADS)
Fonslet, J.; Lee, B. Q.; Tran, T. A.; Siragusa, M.; Jensen, M.; Kibédi, T.; E Stuchbery, A.; Severin, G. W.
2018-01-01
135La has favorable nuclear and chemical properties for Auger-based targeted internal radiotherapy. Here we present detailed investigations of the production, emissions, and dosimetry related to 135La therapy. 135La was produced by 16.5 MeV proton irradiation of metallic natBa on a medical cyclotron, and was isolated and purified by trap-and-release on weak cation-exchange resin. The average production rate was 407 ± 19 MBq µA-1 (saturation activity), and the radionuclidic purity was 98% at 20 h post irradiation. Chemical separation recovered > 98 % of the 135La with an effective molar activity of 70 ± 20 GBq µmol-1. To better assess cellular and organ dosimetry of this nuclide, we have calculated the x-ray and Auger emission spectra using a Monte Carlo model accounting for effects of multiple vacancies during the Auger cascade. The generated Auger spectrum was used to calculate cellular S-factors. 135La was produced with high specific activity, reactivity, radionuclidic purity, and yield. The emission spectrum and the dosimetry are favorable for internal radionuclide therapy.
Enhancement of radiation cytotoxicity by gold nanoparticles in MCF-7 breast cancer cell lines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosli, Nur Shafawati binti; Rahman, Azhar Abdul; Aziz, Azlan Abdul
2015-04-24
Therapy combined with metallic nanoparticles is a new way to treat cancer, in which gold nanoparticles (AuNPs) are injected through intravenous administration and bound to tumor sites. Radiotherapy aims to deliver a high therapeutic dose of ionizing radiation to the tumor without exceeding normal tissue tolerance. The use of AuNPs which is a high-atomic-number (Z) material in radiotherapy will provide a high probability for photon interaction by photoelectric effect. These provide advantages in terms of radiation dose enhancement. The high linear energy transfer and short range of photoelectric interaction products (photoelectrons, characteristic x-rays, Auger electrons) produce localized dose enhancement ofmore » the tumor. In this work, breast cancer cell lines (MCF-7) are seeded in the 96-well plate and were treated with 13 nm AuNPs before they were irradiated with 6 MV and 10 MV photon beam from a medical linear accelerator at various radiation doses. To validate the enhanced killing effect, both with and without AuNPs MCF-7 cells is irradiated simultaneously. By comparison, the results show that AuNPs significantly enhance cancer killing.« less
Lee, Junghoon; Carass, Aaron; Jog, Amod; Zhao, Can; Prince, Jerry L
2017-02-01
Accurate CT synthesis, sometimes called electron density estimation, from MRI is crucial for successful MRI-based radiotherapy planning and dose computation. Existing CT synthesis methods are able to synthesize normal tissues but are unable to accurately synthesize abnormal tissues (i.e., tumor), thus providing a suboptimal solution. We propose a multi-atlas-based hybrid synthesis approach that combines multi-atlas registration and patch-based synthesis to accurately synthesize both normal and abnormal tissues. Multi-parametric atlas MR images are registered to the target MR images by multi-channel deformable registration, from which the atlas CT images are deformed and fused by locally-weighted averaging using a structural similarity measure (SSIM). Synthetic MR images are also computed from the registered atlas MRIs by using the same weights used for the CT synthesis; these are compared to the target patient MRIs allowing for the assessment of the CT synthesis fidelity. Poor synthesis regions are automatically detected based on the fidelity measure and refined by a patch-based synthesis. The proposed approach was tested on brain cancer patient data, and showed a noticeable improvement for the tumor region.
Mohammadi, Narmin; Seyednejad, Farshad; Oskoee, Parnian Alizadeh; Savadi Oskoee, Siavash; Ebrahimi Chaharom, Mohammad Esmaeil
2008-01-01
Salivary glands are very susceptible to radiation and any disturbances in their function are detrimental to the hard tissues in the oral cavity. The aim of this study was to evaluate posterior class V dental caries in patients with head and neck cancers undergoing radiotherapy. In this study, twenty seven patients undergoing conventional radiotherapy were included. Class V dental caries of posterior teeth in these patients were evaluated in three intervals: before treatment, 3 weeks after the initiation of the treatment, and at the end of the treatment. Differences of mean caries activity between intervals were evaluated using paired sample t-test. There were no class V decays prior to radiotherapy. Mean percentage of class V caries three weeks after radiotherapy and at the end of radiotherapy were 28.42% ± 14.41 and 67.05% ± 19.02, respectively. There were statistically signifi-cant differences in mean values among three stages (P = 0.00025). The results of the present study re-vealed that radiotherapy in patients with head and neck cancers causes class V dental caries on posteri-or teeth.
Zahoor, T; Dawson, R; Sen, M; Makura, Z
2017-06-01
The choices made by patients offered treatment for early laryngeal cancer with radiotherapy or transoral laser resection were reviewed. A prospective review was conducted of all patients diagnosed and treated for early laryngeal carcinoma from December 2002 to September 2009 at the Leeds Teaching Hospitals NHS Trust. A total of 209 patients with tumour stage T1 or T2 laryngeal cancer were treated; each new patient suitable for radiotherapy or transoral laser resection was seen jointly by the clinical (radiation) oncologist and head and neck surgeon, and offered the choice of treatment. Of the patients, 47.4 per cent were given a choice between radiotherapy and transoral laser resection; 51.2 per cent were advised to have radiotherapy, and there were no records for the remaining 1.4 per cent. From those given the choice, 59.6 per cent chose transoral laser resection (p < 0.02 (t-test)) and 35.4 per cent chose radiotherapy. When given the choice, a statistically significant majority of patients choose transoral laser resection rather than radiotherapy.
Silver nanoparticles: a novel radiation sensitizer for glioma?
NASA Astrophysics Data System (ADS)
Liu, Peidang; Huang, Zhihai; Chen, Zhongwen; Xu, Ruizhi; Wu, Hao; Zang, Fengchao; Wang, Cailian; Gu, Ning
2013-11-01
Malignant gliomas are the most common primary intracranial tumors with a dismal prognosis. Previous investigations by our group demonstrated the radiosensitizing effect of silver nanoparticles (AgNPs) on glioma cells in vitro. The goal of the present study was to evaluate the efficacy of intratumoral administration of AgNPs in combination with a single dose of ionizing radiation at clinically relevant MV energies for the treatment of C6 glioma-bearing rats. AgNPs (10 or 20 μg/10 μl) were stereotactically administered on day 8 after tumor implantation. One day after AgNP injection, rats bearing glioma received 10 Gy radiation. The mean survival times were 100.5 and 98 days, the corresponding percent increase in life spans was 513.2% and 497.7%, and the cure rates were 41.7 and 38.5% at 200 days for the 10 and 20 μg AgNPs and radiation combination groups, respectively. In contrast, the mean survival times for irradiated controls, 10 and 20 μg AgNPs alone, and untreated controls were 24.5, 16.1, 19.4, and 16.4 days, respectively. Furthermore, a cooperative antiproliferative and proapoptotic effect was obtained when gliomas were treated with AgNPs followed by radiotherapy. Our results showed the therapeutic efficacy of AgNPs in combination with radiotherapy without apparent systemic toxicity, suggesting the clinical potential of AgNPs in improving the outcome of malignant glioma radiotherapy.Malignant gliomas are the most common primary intracranial tumors with a dismal prognosis. Previous investigations by our group demonstrated the radiosensitizing effect of silver nanoparticles (AgNPs) on glioma cells in vitro. The goal of the present study was to evaluate the efficacy of intratumoral administration of AgNPs in combination with a single dose of ionizing radiation at clinically relevant MV energies for the treatment of C6 glioma-bearing rats. AgNPs (10 or 20 μg/10 μl) were stereotactically administered on day 8 after tumor implantation. One day after AgNP injection, rats bearing glioma received 10 Gy radiation. The mean survival times were 100.5 and 98 days, the corresponding percent increase in life spans was 513.2% and 497.7%, and the cure rates were 41.7 and 38.5% at 200 days for the 10 and 20 μg AgNPs and radiation combination groups, respectively. In contrast, the mean survival times for irradiated controls, 10 and 20 μg AgNPs alone, and untreated controls were 24.5, 16.1, 19.4, and 16.4 days, respectively. Furthermore, a cooperative antiproliferative and proapoptotic effect was obtained when gliomas were treated with AgNPs followed by radiotherapy. Our results showed the therapeutic efficacy of AgNPs in combination with radiotherapy without apparent systemic toxicity, suggesting the clinical potential of AgNPs in improving the outcome of malignant glioma radiotherapy. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr01351k
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bahar, N; Roberts, K; Stabile, F
Purpose: Medical intervention following a major, unplanned radiation event can elevate the human whole body exposure LD50 from 3 to 7 Gy. On a large scale, intervention cannot be achieved effectively without accurate and efficient triage. Current methods of retrospective biodosimetry are restricted in capability and applicability; published human data is limited. We aim to further develop, validate, and optimize an automated field-deployable in vivo electron paramagnetic resonance (EPR) instrument that can fill this need. Methods: Ionizing radiation creates highly-stable, carbonate-based free radicals within tooth enamel. Using a process similar to nuclear magnetic resonance, EPR directly measures the presence ofmore » radiation-induced free radicals. We performed baseline EPR measurements on one of the upper central incisors of total body irradiation (TBI) and head and neck (H&N) radiotherapy patients before their first treatment. Additional measurements were performed between subsequent fractions to examine the EPR response with increasing radiation dose. Independent dosimetry measurements were performed with optically-stimulated luminescent dosimeters (OSLDs) and diodes to more accurately establish the relationship between EPR signal and delivered radiation dose. Results: 36 EPR measurements were performed over the course of four months on two TBI and four H & N radiotherapy patients. We observe a linear increase in EPR signal with increasing dose across the entirety of the tested range. A linear least squares-weighted fit of delivered dose versus measured signal amplitude yields an adjusted R-square of 0.966. The standard error of inverse prediction (SEIP) is 1.77 Gy. For doses up to 7 Gy, the range most relevant to triage, we calculate an SEIP of 1.29 Gy. Conclusion: EPR spectroscopy provides a promising method of retrospective, non-invasive, in vivo biodosimetry. Our preliminary data show an excellent correlation between predicted signal amplitude and delivered dose. With further development, a robust means of predicting delivered radiation dose from EPR measurements is expected. This project was funded by the Biomedical Advanced Research and Development Authority (BARDA) within the U.S. Department of Health and Human Services subcontracted through the Geisel School of Medicine at Dartmouth and by the Dartmouth Physically-Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR) Pilot Program.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazalova, M; Qu, B; Palma, B
2014-06-15
Purpose: To develop a tool for treatment planning optimization for fast radiotherapy delivered with very high-energy electron beams (VHEE) and to compare VHEE plans to state-of-the-art plans for challenging pelvis and H'N cases. Methods: Treatment planning for radiotherapy delivered with VHEE scanning pencil beams was performed by integrating EGSnrc Monte Carlo (MC) dose calculations with spot scanning optimization run in a research version of RayStation. A Matlab GUI for MC beamlet generation was developed, in which treatment parameters such as the pencil beam size and spacing, energy and number of beams can be selected. Treatment planning study for H'N andmore » pelvis cases was performed and the effect of treatment parameters on the delivered dose distributions was evaluated and compared to the clinical treatment plans. The pelvis case with a 691cm3 PTV was treated with 2-arc 15MV VMAT and the H'N case with four PTVs with total volume of 531cm3 was treated with 4-arc 6MV VMAT. Results: Most studied VHEE plans outperformed VMAT plans. The best pelvis 80MeV VHEE plan with 25 beams resulted in 12% body dose sparing and 8% sparing to the bowel and right femur compared to the VMAT plan. The 100MeV plan was superior to the 150MeV plan. Mixing 100 and 150MeV improved dose sparing to the bladder by 7% compared to either plan. Plans with 16 and 36 beams did not significantly affect the dose distributions compared to 25 beam plans. The best H'N 100MeV VHEE plan decreased mean doses to the brainstem, chiasm, and both globes by 10-42% compared to the VMAT plan. Conclusion: The pelvis and H'N cases suggested that sixteen 100MeV beams might be sufficient specifications of a novel VHEE treatment machine. However, optimum machine parameters will be determined with the presented VHEE treatment-planning tool for a large number of clinical cases. BW Loo and P Maxim received research support from RaySearch Laboratories. E Hynning and B Hardemark are employees of RaySearch Laboratories.« less
Commercial glass beads as TLDs in radiotherapy produced by different manufacturers
NASA Astrophysics Data System (ADS)
Jafari, S. M.; Bates, N. M.; Jupp, T.; Abdul Sani, S. F.; Nisbet, A.; Bradley, D. A.
2017-08-01
While commercial jewellery glass beads offer the basis of novel radiotherapy TL dosimetry (Jafari et al. 2014a,b,c, 2015a,b), detailed study of TL variation is required for the products from various manufacturers. Investigation is made for glass beads from four manufacturers from four countries: China (Rocaille), Japan (Mill Hill), Indonesia (TOHO™) and Czech Republic (Czech). Sample composition was determined using an energy-dispersive X-ray unit coupled to a scanning electron microscope. Values of mass attenuation coefficient, μ/ρ, as a function of photon energy were then calculated for photons of energy 1 keV to 10 MeV, using the National Institute of Standards and Technology XCOM program. Radiation and energy response were determined using X-rays generated at accelerating potentials from 80 kVp to 6 MV (TPR20/10=0.670). All bead types showed TL to be linear with dose (R2>0.999). Glow curve dosimetric peaks reached a maximum value at 300 °C for the Toho and 290 °C for the Czech and Mill Hill products but was between 200-250 °C for the Rocaille product. Radiation sensitivity following mass normalisation varied within an order of magnitude; Toho samples showed the greatest and Rocaille the least sensitivity. For the Toho, Czech, Rocaille and Mill Hill samples the energy responses at 80 kVp were 5.0, 4.0, 3.6 and 3.3 times that obtained at 6 MV. All four glass bead types offer potential use as TL dosimeters over doses commonly applied in radiotherapy. Energy response variation was <1% at 6 MV but significant variation was found for photon beam energies covering the kV range; careful characterisation is required if use at this range is intended.
Radiation techniques used in patients with breast cancer: Results of a survey in Spain
Algara, Manuel; Arenas, Meritxell; De las Peñas Eloisa Bayo, Dolores; Muñoz, Julia; Carceller, José Antonio; Salinas, Juan; Moreno, Ferran; Martínez, Francisco; González, Ezequiel; Montero, Ángel
2012-01-01
Aim To evaluate the resources and techniques used in the irradiation of patients with breast cancer after lumpectomy or mastectomy and the status of implementation of new techniques and therapeutic schedules in our country. Background The demand for cancer care has increased among the Spanish population, as long as cancer treatment innovations have proliferated. Radiation therapy in breast cancer has evolved exponentially in recent years with the implementation of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, image guided radiotherapy and hypofractionation. Material and Methods An original survey questionnaire was sent to institutions participating in the SEOR-Mama group (GEORM). In total, the standards of practice in 969 patients with breast cancer after surgery were evaluated. Results The response rate was 70% (28/40 centers). In 98.5% of cases 3D conformal treatment was used. All the institutions employed CT-based planning treatment. Boost was performed in 56.4% of patients: electrons in 59.8%, photons in 23.7% and HDR brachytherapy in 8.8%. Fractionation was standard in 93.1% of patients. Supine position was the most frequent. Only 3 centers used prone position. The common organs of risk delimited were: homolateral lung (80.8%) and heart (80.8%). In 84% histograms were used. An 80.8% of the centers used isocentric technique. In 62.5% asymmetric fields were employed. CTV was delimited in 46.2%, PTV in 65% and both in 38.5%. A 65% of the centers checked with portal films. IMRT and hypofractionation were used in 1% and in 5.5% respectively. Conclusion In most of centers, 3D conformal treatment and CT-based planning treatment were used. IMRT and hypofractionation are currently poorly implemented in Spain. PMID:24377012
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beltran, Chris; Herman, Michael G.; Davis, Brian J.
2008-01-01
Purpose: To determine planning target volume (PTV) margins for prostate radiotherapy based on the internal margin (IM) (intrafractional motion) and the setup margin (SM) (interfractional motion) for four daily localization methods: skin marks (tattoo), pelvic bony anatomy (bone), intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. Methods and Materials: Forty prostate cancer patients were treated with external radiotherapy according to an online localization protocol using four intraprostatic gold seeds and electronic portal images (EPIs). Daily localization and treatment EPIs were obtained. These data allowed inter- and intrafractional analysis of prostate motion. The SM for the fourmore » daily localization methods and the IM were determined. Results: A total of 1532 fractions were analyzed. Tattoo localization requires a SM of 6.8 mm left-right (LR), 7.2 mm inferior-superior (IS), and 9.8 mm anterior-posterior (AP). Bone localization requires 3.1, 8.9, and 10.7 mm, respectively. The 5-mm threshold localization requires 4.0, 3.9, and 3.7 mm. No threshold localization requires 3.4, 3.2, and 3.2 mm. The intrafractional prostate motion requires an IM of 2.4 mm LR, 3.4 mm IS and AP. The PTV margin using the 5-mm threshold, including interobserver uncertainty, IM, and SM, is 4.8 mm LR, 5.4 mm IS, and 5.2 mm AP. Conclusions: Localization based on EPI with implanted gold seeds allows a large PTV margin reduction when compared with tattoo localization. Except for the LR direction, bony anatomy localization does not decrease the margins compared with tattoo localization. Intrafractional prostate motion is a limiting factor on margin reduction.« less
Physical interactions of charged particles for radiotherapy and space applications.
Zeitlin, Cary
2012-11-01
In this paper, the basic physics by which energetic charged particles deposit energy in matter is reviewed. Energetic charged particles are used for radiotherapy and are encountered in spaceflight, where they pose a health risk to astronauts. They interact with matter through nuclear and electromagnetic forces. Deposition of energy occurs mostly along the trajectory of the incoming particle, but depending on the type of incident particle and its energy, there is some nonzero probability for energy deposition relatively far from the nominal trajectory, either due to long-ranged knock-on electrons (sometimes called delta rays) or from the products of nuclear fragmentation, including neutrons. In the therapy setting, dose localization is of paramount importance, and the deposition of energy outside nominal treatment volumes complicates planning and increases the risk of secondary cancers as well as noncancer effects in normal tissue. Statistical effects are also important and will be discussed. In contrast to radiation therapy patients, astronauts in space receive comparatively small whole-body radiation doses from energetic charged particles and associated secondary radiation. A unique aspect of space radiation exposures is the high-energy heavy-ion component of the dose. This is not present in terrestrial exposures except in carbon-ion radiotherapy. Designers of space missions must limit exposures to keep risk within acceptable limits. These limits are, at present, defined for low-Earth orbit, but not for deep-space missions outside the geomagnetosphere. Most of the uncertainty in risk assessment for such missions comes from the lack of understanding of the biological effectiveness of the heavy-ion component, with a smaller component due to uncertainties in transport physics and dosimetry. These same uncertainties are also critical in the therapy setting.
Diegeler, Sebastian; Hellweg, Christine E
2017-01-01
Ionizing radiation can affect the immune system in many ways. Depending on the situation, the whole body or parts of the body can be acutely or chronically exposed to different radiation qualities. In tumor radiotherapy, a fractionated exposure of the tumor (and surrounding tissues) is applied to kill the tumor cells. Currently, mostly photons, and also electrons, neutrons, protons, and heavier particles such as carbon ions, are used in radiotherapy. Tumor elimination can be supported by an effective immune response. In recent years, much progress has been achieved in the understanding of basic interactions between the irradiated tumor and the immune system. Here, direct and indirect effects of radiation on immune cells have to be considered. Lymphocytes for example are known to be highly radiosensitive. One important factor in indirect interactions is the radiation-induced bystander effect which can be initiated in unexposed cells by expression of cytokines of the irradiated cells and by direct exchange of molecules via gap junctions. In this review, we summarize the current knowledge about the indirect effects observed after exposure to different radiation qualities. The different immune cell populations important for the tumor immune response are natural killer cells, dendritic cells, and CD8+ cytotoxic T-cells. In vitro and in vivo studies have revealed the modulation of their functions due to ionizing radiation exposure of tumor cells. After radiation exposure, cytokines are produced by exposed tumor and immune cells and a modulated expression profile has also been observed in bystander immune cells. Release of damage-associated molecular patterns by irradiated tumor cells is another factor in immune activation. In conclusion, both immune-activating and -suppressing effects can occur. Enhancing or inhibiting these effects, respectively, could contribute to modified tumor cell killing after radiotherapy.
Saito, Tetsuo; Matsuyama, Tomohiko; Toya, Ryo; Fukugawa, Yoshiyuki; Toyofuku, Takamasa; Semba, Akiko; Oya, Natsuo
2014-01-01
We evaluated the effects of respiratory gating on treatment accuracy in lung cancer patients undergoing lung stereotactic body radiotherapy by using electronic portal imaging device (EPID) images. Our study population consisted of 30 lung cancer patients treated with stereotactic body radiotherapy (48 Gy/4 fractions/4 to 9 days). Of these, 14 were treated with- (group A) and 16 without gating (group B); typically the patients whose tumors showed three-dimensional respiratory motion ≧5 mm were selected for gating. Tumor respiratory motion was estimated using four-dimensional computed tomography images acquired during treatment simulation. Tumor position variability during all treatment sessions was assessed by measuring the standard deviation (SD) and range of tumor displacement on EPID images. The two groups were compared for tumor respiratory motion and position variability using the Mann-Whitney U test. The median three-dimensional tumor motion during simulation was greater in group A than group B (9 mm, range 3-30 mm vs. 2 mm, range 0-4 mm; p<0.001). In groups A and B the median SD of the tumor position was 1.1 mm and 0.9 mm in the craniocaudal- (p = 0.24) and 0.7 mm and 0.6 mm in the mediolateral direction (p = 0.89), respectively. The median range of the tumor position was 4.0 mm and 3.0 mm in the craniocaudal- (p = 0.21) and 2.0 mm and 1.5 mm in the mediolateral direction (p = 0.20), respectively. Although patients treated with respiratory gating exhibited greater respiratory tumor motion during treatment simulation, tumor position variability in the EPID images was low and comparable to patients treated without gating. This demonstrates the benefit of respiratory gating.
Brink, Carsten; Lorenzen, Ebbe L; Krogh, Simon Long; Westberg, Jonas; Berg, Martin; Jensen, Ingelise; Thomsen, Mette Skovhus; Yates, Esben Svitzer; Offersen, Birgitte Vrou
2018-01-01
The current study evaluates the data quality achievable using a national data bank for reporting radiotherapy parameters relative to the classical manual reporting method of selected parameters. The data comparison is based on 1522 Danish patients of the DBCG hypo trial with data stored in the Danish national radiotherapy data bank. In line with standard DBCG trial practice selected parameters were also reported manually to the DBCG database. Categorical variables are compared using contingency tables, and comparison of continuous parameters is presented in scatter plots. For categorical variables 25 differences between the data bank and manual values were located. Of these 23 were related to mistakes in the manual reported value whilst the remaining two were a wrong classification in the data bank. The wrong classification in the data bank was related to lack of dose information, since the two patients had been treated with an electron boost based on a manual calculation, thus data was not exported to the data bank, and this was not detected prior to comparison with the manual data. For a few database fields in the manual data an ambiguity of the parameter definition of the specific field is seen in the data. This was not the case for the data bank, which extract all data consistently. In terms of data quality the data bank is superior to manually reported values. However, there is a need to allocate resources for checking the validity of the available data as well as ensuring that all relevant data is present. The data bank contains more detailed information, and thus facilitates research related to the actual dose distribution in the patients.
Merchant, S; O'Connor, M; Halkett, G
2017-03-01
Radiation therapists (RTs) plan and deliver radiotherapy treatment for patients diagnosed with cancer. They need to communicate regularly with their patients and may have a role to play in reducing patient anxiety and distress. The objectives were to explore how the environment of radiotherapy departments supports or inhibits communication generally and information giving and supportive care provision in particular. An ethnographic approach was used to gather rich descriptive data through observations and interviews conducted in two Australian radiotherapy centres. Time, space and a technology driven culture was found to negatively affect the quality of interaction that occurred between RTs and their patients. This research has shown design/modification of spaces is needed in the radiotherapy environment to reflect a patient care centred culture and to enhance opportunities for RTs to provide supportive care for their patients. © 2015 John Wiley & Sons Ltd.
Radiotherapy in patients with connective tissue diseases.
Giaj-Levra, Niccolò; Sciascia, Savino; Fiorentino, Alba; Fersino, Sergio; Mazzola, Rosario; Ricchetti, Francesco; Roccatello, Dario; Alongi, Filippo
2016-03-01
The decision to offer radiotherapy in patients with connective tissue diseases continues to be challenging. Radiotherapy might trigger the onset of connective tissue diseases by increasing the expression of self-antigens, diminishing regulatory T-cell activity, and activating effectors of innate immunity (dendritic cells) through Toll-like receptor-dependent mechanisms, all of which could potentially lead to breaks of immune tolerance. This potential risk has raised some debate among radiation oncologists about whether patients with connective tissue diseases can tolerate radiation as well as people without connective tissue diseases. Because the number of patients with cancer and connective tissue diseases needing radiotherapy will probably increase due to improvements in medical treatment and longer life expectancy, the issue of interactions between radiotherapy and connective tissue diseases needs to be clearer. In this Review, we discuss available data and evidence for patients with connective tissue diseases treated with radiotherapy. Copyright © 2016 Elsevier Ltd. All rights reserved.
Visualization of complex DNA double-strand breaks in a tumor treated with carbon ion radiotherapy
Oike, Takahiro; Niimi, Atsuko; Okonogi, Noriyuki; Murata, Kazutoshi; Matsumura, Akihiko; Noda, Shin-Ei; Kobayashi, Daijiro; Iwanaga, Mototaro; Tsuchida, Keisuke; Kanai, Tatsuaki; Ohno, Tatsuya; Shibata, Atsushi; Nakano, Takashi
2016-01-01
Carbon ion radiotherapy shows great potential as a cure for X-ray-resistant tumors. Basic research suggests that the strong cell-killing effect induced by carbon ions is based on their ability to cause complex DNA double-strand breaks (DSBs). However, evidence supporting the formation of complex DSBs in actual patients is lacking. Here, we used advanced high-resolution microscopy with deconvolution to show that complex DSBs are formed in a human tumor clinically treated with carbon ion radiotherapy, but not in a tumor treated with X-ray radiotherapy. Furthermore, analysis using a physics model suggested that the complexity of radiotherapy-induced DSBs is related to linear energy transfer, which is much higher for carbon ion beams than for X-rays. Visualization of complex DSBs in clinical specimens will help us to understand the anti-tumor effects of carbon ion radiotherapy. PMID:26925533
Mahdavi, Hoda; Jabbari, Keyvan; Roayaei, Mahnaz
2016-01-01
Delivering radiotherapy to the postmastectomy chest wall can be achieved using matched electron fields. Surgical defects of the chest wall change the dose distribution of electrons. In this study, the improvement of dose homogeneity using simple, nonconformal techniques of thermoplastic bolus application on a defect is evaluated. The proposed phantom design improves the capability of film dosimetry for obtaining dose profiles of a patient's anatomical condition. A modeled electron field of a patient with a postmastectomy inward surgical defect was planned. High energy electrons were delivered to the phantom in various settings, including no bolus, a bolus that filled the inward defect (PB0), a uniform thickness bolus of 5 mm (PB1), and two 5 mm boluses (PB2). A reduction of mean doses at the base of the defect was observed by any bolus application. PB0 increased the dose at central parts of the defect, reduced hot areas at the base of steep edges, and reduced dose to the lung and heart. Thermoplastic boluses that compensate a defect (PB0) increased the homogeneity of dose in a fixed depth from the surface; adversely, PB2 increased the dose heterogeneity. This study shows that it is practical to investigate dose homogeneity profiles inside a target volume for various techniques of electron therapy. PMID:27051169
Carl, Jesper; Sander, Lotte
2015-06-01
To report results from the five-year follow-up on a previously reported study using image-guided radiotherapy (IGRT) of localized or locally advanced prostate cancer (PC) and a removable prostate stent as fiducial. Patients with local or locally advanced PC were treated using five-field 3D conformal radiotherapy (3DRT). The clinical target volumes (CTV) were treated to 78 Gy in 39 fractions using daily on-line image guidance (IG). Late genito-urinary (GU) and gastro-intestinal (GI) toxicities were scored using the radiotherapy oncology group (RTOG) score and the common toxicity score of adverse events (CTC) score. Urinary symptoms were also scored using the international prostate symptom score (IPSS). Median observation time was 5.4 year. Sixty-two of the 90 patients from the original study cohort were eligible for toxicity assessment. Overall survival, cancer-specific survival and biochemical freedom from failure were 85%, 96% and 80%, respectively at five years after radiotherapy. Late toxicity GU and GI RTOG scores≥2 were 5% and 0%. Comparing pre- and post-radiotherapy IPSS scores indicate that development in urinary symptoms after radiotherapy may be complex. Prostate image-guided radiotherapy using a prostate stent demonstrated survival data comparable with recently published data. GU and GI toxicities at five-year follow-up were low and comparable to the lowest toxicity rates reported. These findings support that the precision of the prostate stent technique is at least as good as other techniques. IPSS revealed a complex development in urinary symptoms after radiotherapy.
Chow, E; Hird, A; Zhang, Liying; Sinclair, E; Danjoux, C; Barnes, E; Tsao, M; Barbera, L; Wong, Shun; Vieth, R
2009-05-01
To examine the effect of radiotherapy for bone metastases on urinary markers of osteoclast activity. Patients with radiological evidence of bone metastases planned for palliative radiotherapy were eligible for the study. A urine specimen was collected before and 1 month after radiotherapy to assess levels of calcium, creatinine, magnesium, phosphate, N-telopeptide and pyridinoline. The Brief Pain Inventory was completed in person at baseline and by telephone follow-up at 1 month after radiotherapy. Patients were classified as responders (complete or partial pain response) or non-responders (stable or progressive pain) to radiotherapy based on the International Bone Metastases Consensus Criteria for end point measurements. Absolute values of urine markers were compared between responders and non-responders, or between responders and patients with progression. Our study population consisted of 74 men and 51 women. A single 8 Gy or 20 Gy in five daily fractions were commonly employed. At the 1 month follow-up, all Brief Pain Inventory functional interference scores showed a highly significant decrease from baseline (P<0.01). From our study population, 58 (64%) were classified as responders and 57 (46%) as non-responders to radiotherapy. We compared the urinary markers between the responders and the non-responders. There were no statistically significant differences between the two groups either in terms of baseline markers or in terms of month 1 follow-up markers. There was no significant change from baseline to the 1 month follow-up in responders or in non-responders to radiotherapy. Baseline levels of urinary markers could not predict which patient would benefit from palliative radiotherapy.
Graham, P H; Graham, J L
2009-12-01
Proscription of antiperspirant or deodorant use during adjuvant breast radiotherapy is common. The investigators were seeking an information base to facilitate design of an appropriate controlled trial of the use of deodorants during radiotherapy. The first component consisted of a survey of women after adjuvant breast radiotherapy seeking information about routine deodorant use and potential concern if deodorants were not permitted during radiotherapy. The second component comprised a literature search for any existing controlled evidence regarding harm from deodorant use during radiotherapy. Four hundred fourteen women completed surveys. Two hundred eighty recalled advice against deodorants. Two hundred ninety-nine women routinely used deodorants, 70% of whom used roll-on products. Forty-five continued deodorant use during radiation, 20 of these despite recalling advice not to wear a deodorant. Of the 233 women who routinely wore a deodorant but abstained during radiotherapy, 19% expressed a lot of concern about body odour and 45% were slightly concerned. Three controlled studies totalling 310 patients report specific deodorants versus no deodorant use which did not show statistically significantly increased skin reactions, but had only a small subset with axillary irradiation. The proscription of deodorant use during radiotherapy is of unproven benefit and causes body odour concern to the majority of women who are usual deodorant users. The next most appropriate trial would compare use of the usual deodorant versus no deodorant, would encompass a significant number of women with radiotherapy to the axilla or application of deodorant to irradiated skin areas, and include endpoints other than skin reaction alone.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodriguez-Fernandez, Luis
2010-09-10
Although the developments of particle accelerators are devoted to basic study of matter constituents, since the beginning these machines have been applied with different purposes in many areas also. Today particle accelerators are essential instruments for science and technology. This work presents an overview of the main application for direct particle irradiation with accelerator in material science, biology and medicine. They are used for material synthesis by ion implantation and charged particle irradiation; to make coatings and micromachining; to characterize broad kind of samples by ion beam analysis techniques; as mass spectrometers for atomic isotopes determination. In biomedicine the acceleratorsmore » are applied for the study of effects by charged particles on cells. In medicine the radiotherapy by electron irradiation is widely used, while hadrontherapy is still under development. Also, they are necessary for short life radioisotopes production required in radiodiagnostic.« less
Shirai, Katsuyuki; Kawashima, Motohiro; Saitoh, Jun-Ichi; Abe, Takanori; Fukata, Kyohei; Shigeta, Yuka; Irie, Daisuke; Shiba, Shintaro; Okano, Naoko; Ohno, Tatsuya; Nakano, Takashi
2017-01-01
The safety and efficacy of carbon-ion radiotherapy for advanced non-small cell lung cancer have not been established. We evaluated the clinical outcomes and dose-volume histogram parameters of carbon-ion radiotherapy compared with photon therapy in T2b-4N0M0 non-small cell lung cancer. Twenty-three patients were treated with carbon-ion radiotherapy between May 2011 and December 2015. Seven, 14, and 2 patients had T2b, T3, and T4, respectively. The median age was 78 (range, 53-91) years, with 22 male patients. There were 12 adenocarcinomas, 8 squamous cell carcinomas, 1 non-small cell lung carcinoma, and 2 clinically diagnosed lung cancers. Eleven patients were operable, and 12 patients were inoperable. Most patients (91%) were treated with carbon-ion radiotherapy of 60.0 Gy relative biological effectiveness (RBE) in 4 fractions or 64.0 Gy (RBE) in 16 fractions. Local control and overall survival rates were calculated. Dose-volume histogram parameters of normal lung and tumor coverages were compared between carbon-ion radiotherapy and photon therapies, including three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT). The median follow-up of surviving patients was 25 months. Three patients experienced local recurrence, and the 2-year local control rate was 81%. During follow-up, 5 patients died of lung cancer, and 1 died of intercurrent disease. The 2-year overall survival rate was 70%. Operable patients had a better overall survival rate compared with inoperable patients (100% vs. 43%; P = 0.04). There was no grade ≥2 radiation pneumonitis. In dose-volume histogram analysis, carbon-ion radiotherapy had a significantly lower dose to normal lung and greater tumor coverage compared with photon therapies. Carbon-ion radiotherapy was effectively and safely performed for T2b-4N0M0 non-small cell lung cancer, and the dose distribution was superior compared with those for photon therapies. A Japanese multi-institutional study is ongoing to prospectively evaluate these patients and establish the use of carbon-ion radiotherapy.
Dissociative Electron Attachment in the condensed phase: sample morphology and bio-molecules
NASA Astrophysics Data System (ADS)
Bass, A. D.
2001-10-01
Recent electron impact experiments on condensed plasmid DNA have shown low energy electrons to be remarkably effective in causing damage and reveal that electron-scattering phenomena, such as transient anion formation and their decay via dissociative electron attachment, play a central role in this process. Such experiments may prompt a revision of our understanding of the mutagenic effects of radiation and have significant implications for both radiotherapy and radio-protection. These results can be better understood by investigating electron scattering with the various functional constituents of DNA in condensed environments. Recent work, to be presented here, has focused on electron attachment processes in condensed DNA bases and sugar-like analogues of the DNA backbone, as evidenced by the desorption of fragment anions. Despite this progress, a complete understanding of these processes requires parallel study of simpler `model' systems, which allow the characteristic condensed-phase phenomena modulating electron-scattering to be identified. Factors affecting anion formation and DEA can been classed as either intrinsic (affecting the properties of the resonance) or extrinsic (modifying the energy of electrons before attachment and/or the reactions of fragments, post-dissociation). In this talk we will present new results in which the extrinsic factors of porosity and phase of a sample are probed via the desorption of anionic fragments from either the pure film or from probe molecules condensed upon its surface. We show that anion desorption and hence our ability to observe DEA process, is highly sensitive to sample morphology and phase, a property which can be exploited to study the morphology of the film itself.
Enhancing the effect of 4MeV electron beam using gold nanoparticles in breast cancer cells.
Mehrnia, Somayeh Sadat; Hashemi, Bijan; Mowla, Seyed Javad; Arbabi, Azim
2017-03-01
Gold nanoparticles (GNPs) have been applied as radiosensitizer in radiotherapy. Limited reports have shown that GNPs may be effective as a dose enhancer agent for electron radiation therapy. Some Monte Carlo Simulation studies have shown that selecting suitable size of GNPs and electron energies are critical for effective dose enhancement. The aim of this study was to assess possible radiosensitization effect of GNPs on cancer cell treated with 4MeV electron beams. Approximately 10nm GNPs were synthesized and characterized by electron microscope and dynamic light scattering. MCF-7 and MDA-MB-231 breast cancer cells were used and their viability was measured by MTT assay. Radiosensitization effect of GNPs under 4MeV electron beams was measured by clonogenic assay. The result showed a concentration dependent uptake of GNPs without reducing cell viability at concentrations ≤50mg/L. Incubation of cancer cells with GNPs caused a significant decrease in their viability following exposure to electron beams as well as a decrease in their survival fraction when compared to control. The sensitizer enhancement ratio (SER) by electron beams in MCF-7 cells was 1.43 and 1.40 in presence of 25 and 50mg/L GNPs, respectively. For MDA-MB-231 cells, it was 1.62 in presence of 25mg/L GNPs. Our data demonstrated the significant dose enhancement of the GNPs in combination with 4MeV electron beams that could be applicable for the treatment of superficial tumors and intra operative radiation therapy. Copyright © 2017. Published by Elsevier Ltd.
Deterioration of duodenal lymphangiectasia after radiotherapy for gastric MALT lymphoma
Iwamuro, Masaya; Tanaka, Takehiro; Kanzaki, Hiromitsu; Kawano, Seiji; Kawahara, Yoshiro; Iwasaki, Yoshiaki; Okada, Hiroyuki
2017-01-01
A 68-year-old Japanese woman underwent radiotherapy for gastric lymphoma. Although lymphangiectasia was sparsely observed in the second portion of the duodenum before radiotherapy, the number of pinpoint white spots obviously increased after the treatment. Although the duodenal lymphangiectasia gradually progressed, the patient had no features of protein-losing enteropathy. This case highlights the importance of endoscopic observation of the duodenum after irradiation to the abdomen as radiotherapy may secondarily cause intestinal lymphangiectasia. PMID:28798810
2014-09-01
Predictive Imaging Biomarker of Response to Stereotactic Ablative Radiotherapy ( SABR ) for Early Lung Cancer PRINCIPAL INVESTIGATOR: Billy W...CONTRACT NUMBER Response to Stereotactic Ablative Radiotherapy ( SABR ) for Early Lung Cancer 5b. GRANT NUMBER W81XWH-12-1-0236 5c...NOTES 14. ABSTRACT Purpose and scope: Stereotactic ablative radiotherapy ( SABR ) has become a new standard of care for early stage lung
2016-09-01
Radiotherapy ( SABR ) for Early Lung Cancer PRINCIPAL INVESTIGATOR: Billy W. Loo, Jr., M.D., Ph.D CONTRACTING ORGANIZATION: Leland Stanford Junior University...CONTRACT NUMBER W81XWH-12-1-0236 Response to Stereotactic Ablative Radiotherapy ( SABR ) for Early Lung Cancer 5b. GRANT NUMBER 5c. PROGRAM...Distribution Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Purpose and scope: Stereotactic ablative radiotherapy ( SABR ) has become a new standard
The role of radiotherapy in the management of POEMS syndrome.
Suh, Yang-Gun; Kim, Young-Suk; Suh, Chang-Ok; Kim, Yu Ri; Cheong, June-Won; Kim, Jin Seok; Cho, Jaeho
2014-11-28
POEMS syndrome is a paraneoplastic syndrome caused by an underlying plasma cell proliferative disease. In this study, we examined the treatment outcomes and role of radiotherapy in the management of POEMS syndrome. In total, 33 patients diagnosed with POEMS syndrome were analyzed. These patients presented with osteosclerotic myeloma (OSM, n = 13), Castleman's disease (CD, n = 4), OSM with CD (n = 10), and vascular endothelial growth factor elevation without gross lesions (VEGFe, n = 6), respectively. The patients were treated by radiotherapy alone (n = 4), chemotherapy alone (n = 16), or a combination thereof (n = 9). The clinical response rates of radiotherapy, chemotherapy, and radiotherapy plus chemotherapy were 75%, 69%, and 89%, respectively. In addition, the hematologic response rates were 50%, 69%, and 71%, respectively. Among the six patients with limited multiple lesions who underwent radiotherapy, the clinical symptoms were improved in five patients after radiotherapy. The median progression-free survival (PFS) was 51 months, and the median overall survival (OS) was 65 months. In univariate analysis, the administration of chemotherapy was significantly associated with better PFS (p = 0.007) and OS (p = 0.020). In contrast, underlying VEGFe was a significant factor worsening PFS (p = 0.035) and OS (p = 0.008). Radiotherapy produces a reliable clinical response and is effective in improving POEMS-associated symptoms that are refractory to chemotherapy in selected patients with clustered or limited multiple lesions that can be covered by single radiation field.
Adaptive radiotherapy for head and neck cancers: Fact or fallacy to improve therapeutic ratio?
Li, Y Q; Tan, J S H; Wee, J T S; Chua, M L K
2018-04-23
Modern standards of precision radiotherapy, primarily driven by the technological advances of intensity modulation and image guidance, have led to increased versatility in radiotherapy planning and delivery. The ability to shape doses around critical normal organs, while simultaneously "painting" boost doses to the tumor have translated to substantial therapeutic gains in head and neck cancer patients. Recently, dose adaptation (or adaptive radiotherapy) has been proposed as a novel concept to enhance the therapeutic ratio of head and neck radiotherapy, facilitated in part by the onset of molecular and functional imaging. These contemporary imaging techniques have enabled visualisation of the spatial molecular architecture of the tumor. Daily cone-beam imaging, besides improving treatment accuracy, offers another unique angle to explore radiomics - a novel high throughput feature extraction and selection workflow, for adapting radiotherapy based on real-time tumor changes. Here, we review the existing evidence of molecular and functional imaging in head and neck cancers, as well as the current application of adaptive radiotherapy in the treatment of this tumor type. We propose that adaptive radiotherapy can be further exploited through a systematic application of molecular and functional imaging, including radiomics, at the different phases of planning and treatment. Copyright © 2018 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Nightingale, Chandylen L; Curbow, Barbara A; Wingard, John R; Pereira, Deidre B; Carnaby, Giselle D
2017-01-01
Objective The purpose of this pilot study was to (1) obtain preliminary data on changes in burden and quality of life in head and neck cancer caregivers during and shortly following patient radiotherapy, (2) assess the relationship between perceived social support and burden as well as perceived social support and quality of life in caregivers during radiotherapy, and (3) identify preferences for sources of support among caregivers during radiotherapy. Methods Caregivers completed burden and quality of life instruments at the start of patient radiotherapy (T1), 5 weeks into radiotherapy (T2), and 1 month post-radiotherapy (T3) and instruments for perceived social support and support preferences at T2 only. Results Caregivers showed a trend toward increased burden and worsened quality of life for the majority of subscales at T2 or T3 than at T1. Caregivers reported significantly lower esteem and significantly greater disruption at T2 than at T1 and significantly worse health at T3 than at T2. Higher perceived social support was typically associated with lower burden and higher quality of life at T2. Spouses/partners were the most commonly preferred source of support. Discussion These pilot findings suggest that caregivers experience psychosocial impairments during and shortly after patient radiotherapy, but more research using larger samples is warranted. PMID:27068111
Changes in biophysical properties of the skin following radiotherapy for breast cancer.
Hu, Stephen Chu-Sung; Hou, Ming-Feng; Luo, Kuei-Hau; Chuang, Hung-Yi; Wei, Shu-Yi; Chen, Gwo-Shing; Chiang, Wenchang; Huang, Chih-Jen
2014-12-01
Acute radiation dermatitis is a common adverse effect in patients undergoing radiotherapy for breast cancer. However, the effects of radiotherapy on biophysical properties of the skin have rarely been investigated. In this prospective cohort study, we seek to determine the effects of radiotherapy for breast cancer on skin biophysical parameters. We measured various skin biophysical parameters (skin hydration, pH, sebum level, pigmentation, and blood flow) in 144 breast cancer patients by non-invasive techniques before and after radiotherapy. The measurements were simultaneously performed on the irradiated breast and the corresponding contralateral unirradiated breast for comparison. Following radiotherapy, the irradiated breast showed a significant decrease in skin hydration, increase in skin pH, increase in pigmentation, and increase in cutaneous blood flow. The contralateral unirradiated breast showed a slight increase in pigmentation but no significant changes in any of the other biophysical parameters after radiotherapy. No significant associations were found between patient characteristics (diabetes mellitus, hypertension, type of surgery, chemotherapy, hormone therapy) and changes in skin biophysical parameters following radiotherapy. In conclusion, radiation therapy for breast cancer induces measurable and significant changes in biophysical properties of the skin including hydration, pH, pigmentation, and blood flow. These findings give us a greater understanding of the effects of ionizing radiation on skin physiology, and provide non-invasive and objective methods to assess radiation dermatitis. © 2014 Japanese Dermatological Association.
Hamming-Vrieze, Olga; Navran, Arash; Al-Mamgani, Abrahim; Vogel, Wouter V
2018-06-04
In recent years, the possibility of adapting radiotherapy to changes in biological tissue parameters has emerged. It is hypothesized that early identification of radio-resistant parts of the tumor during treatment provides the possibility to adjust the radiotherapy plan to improve outcome. The aim of this systematic literature review was to evaluate the current state of the art of biological PET-guided adaptive radiotherapy, focusing on dose escalation to radio-resistant tumor. A structured literature search was done to select clinical trials including patients with head and neck cancer of the oral cavity, oropharynx, hypopharynx or larynx, with a PET performed during treatment used to develop biological adaptive radiotherapy by i) delineation of sub-volumes suitable for adaptive re-planning, ii) in silico adaptive treatment planning or iii) treatment of patients with PET based dose escalated adaptive radiotherapy. Nineteen articles were selected, 12 articles analyzing molecular imaging signal during treatment and 7 articles focused on biological adaptive treatment planning, of which two were clinical trials. Studied biological pathways include metabolism (FDG), hypoxia (MISO, FAZA and HX4) and proliferation (FLT). In the development of biological dose adaptation in radiotherapy for head-neck tumors, many aspects of the procedure remain ambiguous. Patient selection, tracer selection for detection of the radio-resistant sub-volumes, timing of adaptive radiotherapy, workflow and treatment planning aspects are discussed in a clinical context.
Bekelman, Justin E.; Deye, James A.; Vikram, Bhadrasain; Bentzen, Soren M.; Bruner, Deborah; Curran, Walter J.; Dignam, James; Efstathiou, Jason A.; FitzGerald, T. J.; Hurkmans, Coen; Ibbott, Geoffrey S.; Lee, J. Jack; Merchant, Timothy E.; Michalski, Jeff; Palta, Jatinder R.; Simon, Richard; Ten Haken, Randal K.; Timmerman, Robert; Tunis, Sean; Coleman, C. Norman; Purdy, James
2012-01-01
Background In the context of national calls for reorganizing cancer clinical trials, the National Cancer Institute (NCI) sponsored a two day workshop to examine the challenges and opportunities for optimizing radiotherapy quality assurance (QA) in clinical trial design. Methods Participants reviewed the current processes of clinical trial QA and noted the QA challenges presented by advanced technologies. Lessons learned from the radiotherapy QA programs of recent trials were discussed in detail. Four potential opportunities for optimizing radiotherapy QA were explored, including the use of normal tissue toxicity and tumor control metrics, biomarkers of radiation toxicity, new radiotherapy modalities like proton beam therapy, and the international harmonization of clinical trial QA. Results Four recommendations were made: 1) Develop a tiered (and more efficient) system for radiotherapy QA and tailor intensity of QA to clinical trial objectives. Tiers include (i) general credentialing, (ii) trial specific credentialing, and (iii) individual case review; 2) Establish a case QA repository; 3) Develop an evidence base for clinical trial QA and introduce innovative prospective trial designs to evaluate radiotherapy QA in clinical trials; and 4) Explore the feasibility of consolidating clinical trial QA in the United States. Conclusion Radiotherapy QA may impact clinical trial accrual, cost, outcomes and generalizability. To achieve maximum benefit, QA programs must become more efficient and evidence-based. PMID:22425219
Montgomery, Guy H; Sucala, Madalina; Dillon, Matthew J; Schnur, Julie B
2017-10-01
Radiotherapy is a common and effective treatment for women with breast cancer. However, radiotherapy has also been shown to adversely affect patients' emotional well-being. Currently, few mind-body interventions are designed to improve patients' quality of life during radiotherapy. One intervention which has demonstrated clinical efficacy in the breast cancer radiotherapy setting is Cognitive-Behavioral Therapy plus Hypnosis. The goal of this study was to investigate the impact of Cognitive-Behavioral Therapy plus Hypnosis on emotional distress in women with breast cancer undergoing radiotherapy. One hundred patients were randomly assigned to either the Cognitive-Behavioral Therapy plus Hypnosis (n = 50) or Attention Control (n = 50) group. Results revealed significant benefits of Cognitive-Behavioral Therapy plus Hypnosis on emotional distress at the mid-point (d = 0.54), the conclusion (d = 0.64), and 4 weeks following the conclusion (d = 0.65) of radiotherapy (all ps < 0.05). In summary, results support further study of Cognitive-Behavioral Therapy plus Hypnosis as an evidence-based intervention to reduce emotional distress in women with breast cancer. Cognitive-Behavioral Therapy plus Hypnosis has the benefits of being brief, noninvasive, lacking side-effects, and producing beneficial effects which last beyond the conclusion of radiotherapy. Given these strengths, we propose that Cognitive-Behavioral Therapy plus Hypnosis is a strong candidate for greater dissemination and implementation in cancer populations.
Male breast cancer: 20-year survival data for post-mastectomy radiotherapy.
Eggemann, Holm; Ignatov, Atanas; Stabenow, Roland; von Minckwitz, Gunter; Röhl, Friedrich Wilhelm; Hass, Peter; Costa, Serban-Dan
2013-08-01
The goal of this population-based study was to determine the impact of post-mastectomy radiation therapy on long-term overall survival (OS) of male patients with breast cancer. We investigated 20-year OS rates of 664 patients diagnosed with primary stage I-III breast cancer in former East Germany between 1970 and 1989. Patients had a radical mastectomy with axillary lymph node dissection without systemic adjuvant therapy. Median follow-up time was 26.2 years (range 19-38 years). 52.4% of the patients had post-mastectomy radiotherapy. Radiotherapy showed different effects in each stage group after 20 years. Whereas there was an OS trend for radiotherapy to harm patients with stage I disease (hazard ratio (HR) 1.45; 95% confidence interval (CI) 0.98-2.15; p = 0.065), radiotherapy showed no benefit in patients with stage II disease (HR 0.82; 95% CI 0.62-1.1; p = 0.15). There was a significant survival benefit for patients with stage III disease receiving radiotherapy (HR 0.60; 95% CI 0.41-0.88; p = 0.008). Post-mastectomy radiotherapy is associated with longer OS in male patients with stage III breast cancer. Male breast cancer patients at stages I and II do not seem to benefit from radiotherapy, but obsolete irradiation techniques might explain adverse long-term effects in earlier stages.
Oedema-based model for diffuse low-grade gliomas: application to clinical cases under radiotherapy.
Badoual, M; Gerin, C; Deroulers, C; Grammaticos, B; Llitjos, J-F; Oppenheim, C; Varlet, P; Pallud, J
2014-08-01
Diffuse low-grade gliomas are characterized by slow growth. Despite appropriate treatment, they change inexorably into more aggressive forms, jeopardizing the patient's life. Optimizing treatments, for example with the use of mathematical modelling, could help to prevent tumour regrowth and anaplastic transformation. Here, we present a model of the effect of radiotherapy on such tumours. Our objective is to explain observed delay of tumour regrowth following radiotherapy and to predict its duration. We have used a migration-proliferation model complemented by an equation describing appearance and draining of oedema. The model has been applied to clinical data of tumour radius over time, for a population of 28 patients. We were able to show that draining of oedema accounts for regrowth delay after radiotherapy and have been able to fit the clinical data in a robust way. The model predicts strong correlation between high proliferation coefficient and low progression-free gain of lifetime, due to radiotherapy among the patients, in agreement with clinical studies. We argue that, with reasonable assumptions, it is possible to predict (precision ~20%) regrowth delay after radiotherapy and the gain of lifetime due to radiotherapy. Our oedema-based model provides an early estimation of individual duration of tumour response to radiotherapy and thus, opens the door to the possibility of personalized medicine. © 2014 John Wiley & Sons Ltd.
Significance of Cox-2 expression in rectal cancers with or without preoperative radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pachkoria, Ketevan; Zhang Hong; Adell, Gunnar
2005-11-01
Purpose: Radiotherapy has reduced local recurrence of rectal cancers, but the result is not satisfactory. Further biologic factors are needed to identify patients for more effective radiotherapy. Our aims were to investigate the relationship of cyclooxygenase-2 (Cox-2) expression to radiotherapy, and clinicopathologic/biologic variables in rectal cancers with or without radiotherapy. Methods and Materials: Cox-2 expression was immunohistochemically examined in distal normal mucosa (n = 28), in adjacent normal mucosa (n = 107), in primary cancer (n = 138), lymph node metastasis (n = 30), and biopsy (n = 85). The patients participated in a rectal cancer trial of preoperative radiotherapy.more » Results: Cox-2 expression was increased in primary tumor compared with normal mucosa (p < 0.0001), but there was no significant change between primary tumor and metastasis. Cox-2 positivity was or tended to be related to more p53 and Ki-67 expression, and less apoptosis (p {<=} 0.05). In Cox-2-negative cases of either biopsy (p = 0.01) or surgical samples (p = 0.02), radiotherapy was related to less frequency of local recurrence, but this was not the case in Cox-2-positive cases. Conclusion: Cox-2 expression seemed to be an early event involved in rectal cancer development. Radiotherapy might reduce a rate of local recurrence in the patients with Cox-2 weakly stained tumors, but not in those with Cox-2 strongly stained tumors.« less
[Current status and potential perspectives in classical radiotherapy technology].
Dabić-Stanković, Kata M; Stanković, Jovan B; Radosević-Jelić, Ljiljana M
2004-01-01
After purchase of radiotherapy equipment in 2003, classic radiation therapy in Serbia will reach the highest world level. In order to define the highest standards in radiation technology, we analyzed the current status and potential perspectives of radiation therapy. An analysis of present situation in the USA, assumed as the most developed in the world, was done. Available data, collected in the last 3 years (equipment assortment, therapy modalities, workload and manpower) for 284 radiotherapy centers, out of potential 2050, were analyzed. Results were presented as crude percentage and matched to point current status. The analysis showed that CLINAC accelerators are the most popular (82.7%), as well as, ADAC (43.7%) and Focus (CMS) (27.4%) systems for therapy planning. Movement towards virtual simulation is evident (59.3%), although classic "simulation" is not fully eliminated from the radiotherapy chain. The most popular brachytherapy afterloader is Microselectron HDR (71%). About 64.4% centers use IMPAC communication/verification/record system that seems more open than Varis. All centers practice modern radiotherapy modalities and techniques (CPRT, IMRT, SRS/SRT, TBI, IORT, IVBHRT, HDR BHRT, etc.). CT and MRI availability is out of question, but PET is available in 3% of centers, however this percentage is rapidly growing. Up to 350 new patients per year are treated by one accelerator (about 35 pts. a day). Centers are relatively small and utilize 2-3 accelerators on average. Average FTE staffing norm is 4 radiation oncologists, 2-3 medical radiotherapy physicists, about 3 certified medical dosimetrists and about 6 radiotherapy technologists. In the past 5 years relative stagnation in classic radiotherapy has been observed. In spite of substantial investments in technology and consequent improvements, as well as wide introduction of computers in radiotherapy, radiotherapy results have not changed significantly. Vendor developement strategies do not point that this trend will change in the next 5 years. On the other hand, wide introduction of the PET in each radiotherapy chain ring (diagnostics, planning, follow-up), could improve results (local and regional control, as well as quality of patients' life).
Lundh, O; Rechatin, C; Faure, J; Ben-Ismaïl, A; Lim, J; De Wagter, C; De Neve, W; Malka, V
2012-06-01
To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research. © 2012 American Association of Physicists in Medicine.
López-Tarjuelo, Juan; Bouché-Babiloni, Ana; Morillo-Macías, Virginia; Santos-Serra, Agustín; Ferrer-Albiach, Carlos
2017-01-01
To estimate angular response deviation of MOSFETs in the realm of intraoperative electron radiotherapy (IOERT), review their energy dependence, and propose unambiguous names for detector rotations. MOSFETs have been used in IOERT. Movement of the detector, namely rotations, can spoil results. We propose yaw, pitch, and roll to name the three possible rotations in space, as these unequivocally name aircraft rotations. Reinforced mobile MOSFETs (model TN-502RDM-H) and an Elekta Precise linear accelerator were used. Two detectors were placed in air for the angular response study and the whole set of five detectors was calibrated as usual to evaluate energy dependence. The maximum readout was obtained with a roll of 90° and 4 MeV. With regard to pitch movement, a substantial drop in readout was achieved at 90°. Significant overresponse was measured at 315° with 4 MeV and at 45° with 15 MeV. Energy response is not different for the following groups of energies: 4, 6, and 9 MeV; and 12 MeV, 15 MeV, and 18 MeV. Our proposal to name MOSFET rotations solves the problem of defining sensor orientations. Angular response could explain lower than expected results when the tip of the detector is lifted due to inadvertent movements. MOSFETs energy response is independent of several energies and differs by a maximum of 3.4% when dependent. This can limit dosimetry errors and makes it possible to calibrate the detectors only once for each group of energies, which saves time and optimizes lifespan of MOSFETs.
Preliminary results of an in-beam PET prototype for proton therapy
NASA Astrophysics Data System (ADS)
Attanasi, F.; Belcari, N.; Camarda, M.; Cirrone, G. A. P.; Cuttone, G.; Del Guerra, A.; Di Rosa, F.; Lanconelli, N.; Rosso, V.; Russo, G.; Vecchio, S.
2008-06-01
Proton therapy can overcome the limitations of conventional radiotherapy due to the more selective energy deposition in depth and to the increased biological effectiveness. Verification of the delivered dose is desirable, but the complete stopping of the protons in patient prevents the application of electronic portal imaging methods that are used in conventional radiotherapy During proton therapy β + emitters like 11C, 15O, 10C are generated in irradiated tissues by nuclear reactions. The measurement of the spatial distribution of this activity, immediately after patient irradiation, can lead to information on the effective delivered dose. First, results of a feasibility study of an in-beam PET for proton therapy are reported. The prototype is based on two planar heads with an active area of about 5×5 cm 2. Each head is made up of a position sensitive photomultiplier coupled to a square matrix of same size of LYSO scintillating crystals (2×2×18 mm 3 pixel dimensions). Four signals from each head are acquired through a dedicated electronic board that performs signal amplification and digitization. A 3D reconstruction of the activity distribution is calculated using an expectation maximization algorithm. To characterize the PET prototype, the detection efficiency and the spatial resolution were measured using a point-like radioactive source. The validation of the prototype was performed using 62 MeV protons at the CATANA beam line of INFN LNS and PMMA phantoms. Using the full energy proton beam and various range shifters, a good correlation between the position of the activity distal edge and the thickness of the beam range shifter was found along the axial direction.
Ojala, J; Hyödynmaa, S; Barańczyk, R; Góra, E; Waligórski, M P R
2014-03-01
Electron radiotherapy is applied to treat the chest wall close to the mediastinum. The performance of the GGPB and eMC algorithms implemented in the Varian Eclipse treatment planning system (TPS) was studied in this region for 9 and 16 MeV beams, against Monte Carlo (MC) simulations, point dosimetry in a water phantom and dose distributions calculated in virtual phantoms. For the 16 MeV beam, the accuracy of these algorithms was also compared over the lung-mediastinum interface region of an anthropomorphic phantom, against MC calculations and thermoluminescence dosimetry (TLD). In the phantom with a lung-equivalent slab the results were generally congruent, the eMC results for the 9 MeV beam slightly overestimating the lung dose, and the GGPB results for the 16 MeV beam underestimating the lung dose. Over the lung-mediastinum interface, for 9 and 16 MeV beams, the GGPB code underestimated the lung dose and overestimated the dose in water close to the lung, compared to the congruent eMC and MC results. In the anthropomorphic phantom, results of TLD measurements and MC and eMC calculations agreed, while the GGPB code underestimated the lung dose. Good agreement between TLD measurements and MC calculations attests to the accuracy of "full" MC simulations as a reference for benchmarking TPS codes. Application of the GGPB code in chest wall radiotherapy may result in significant underestimation of the lung dose and overestimation of dose to the mediastinum, affecting plan optimization over volumes close to the lung-mediastinum interface, such as the lung or heart. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Target coverage in image-guided stereotactic body radiotherapy of liver tumors.
Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M
2007-05-01
To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kimple, Randall J.; Klauber-DeMore, Nancy; Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, NC
2011-02-01
Purpose: Determine cosmetic outcome and toxicity profile of intraoperative radiation delivered before tumor excision for patients with early-stage breast cancer. Methods and Materials: Patients age 48 or older with ultrasound-visible invasive ductal cancers <3 cm and clinically negative lymph nodes were eligible for treatment on this institutional review board-approved Phase II clinical trial. Treatment planning ultrasound was used to select an electron energy and cone size sufficient to cover the tumor plus a 1.5- to 2.0-cm circumferential margin laterally and a 1-cm-deep margin with the 90% isodose line. The dose was prescribed to a nominal 15 Gy and delivered usingmore » a Mobetron electron irradiator before tumor excision by segmental mastectomy. Physician- and patient-assessed cosmetic outcome and patient satisfaction were determined by questionnaire. Results: From March 2003 to July 2007, 71 patients were treated with intraoperative radiation therapy. Of those, 56 patients were evaluable, with a median follow-up of 3.1 years (minimum 1 year). Physician and patient assessment of cosmesis was 'good or excellent' (Radiation Therapy Oncology Group cosmesis scale) in 45/56 (80%) and 32/42 (76%) of all patients, respectively. Eleven patients who received additional whole breast radiation had similar rates of good or excellent cosmesis: 40/48 (83%) and 29/36 (81%), respectively). Grade 1 or 2 acute toxicities were seen in 4/71 (6%) patients. No Grade 3 or 4 toxicities or serious adverse events have been seen. Conclusion: Intraoperative radiotherapy delivered to an in situ tumor is feasible with acceptable acute tolerance. Patient and physician assessment of the cosmetic outcome is good to excellent.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Y; Gan, L; Chen, X
Purpose: To explore the correlations between anatomic features and dose-volumetric parameters in 3DCRT and eComp whole breast irradiation and identify the feasibility of anatomic parameters to predict the planning method selection. Methods: We compared the effectiveness between conventional three-dimensional conformal radiotherapy (3DCRT) and electronic tissue compensation (eComp) for whole breast irradiation. 3DCRT and eComp planning techniques were used to generate treatment plans for 60 whole breast patients, respectively. The planning goal was to cover 95% of the planning target volume (PTV) with 95% of the prescription dose while minimizing dose to lung, heart, and skin. Statistical analyses were performed betweenmore » critical organ doses and patient anatomic features, i.e., central lung distance (CLD), maximal heart distance (MHD), maximal heart length (MHL) and breast separation (BS). Results: Comparing to 3DCRT plans, on the average, eComp treatment planning process was about 7 minutes longer, but resulted in lower lung V20Gy, lower mean skin dose, with similar heart dose. The benefits were more pronounced for larger breast patients. To keep the lung V20Gy lower than 20% and mean skin dose lower than 85% of the prescription dose, eComp was the preferred method for patients with more than 2.3 cm CLD or larger than 22.5 cm BS. Conclusion: The study results may be useful in providing a handy criterion in clinical practice allowing us to easily choose between different planning techniques to satisfy the planning goal with minimal increase in complexity and cost. This study was supported by National Natural Science Foundation of China (NO. 31420103915) and Chongqing Health and Family Planning Commission Project (2015MSXM012).« less
2013-01-01
Background The Montpellier cancer institute phase II trial started in 2004 and evaluated the feasibility of intraoperative radiotherapy (IORT) technique given as a sole radiation treatment for patients with an excellent prognostic and very low recurrence risk. Methods Forty-two patients were included between 2004 and 2007. Inclusion criteria were patients ≥ 65 years old, T0-T1, N0, ductal invasive unifocal carcinoma, free-margin > 2 mm. IORT was delivered using dedicated linear accelerator. One fraction of 21 Gy was prescribed and specified at the 90% isodose using electrons. In vivo dosimetry was performed for all patients. Primary end-point was the quality index. Secondary endpoints were quality of life, local recurrences, cosmetic results, specific and overall survival. Results At inclusion, median age was 72 years (range, 66–80). Median tumor diameter was 10 mm. All patients received the total prescribed dose. No acute grade 3 toxicities were observed. Late cosmetic results were good at 5 years despite the poor agreement of accuracy assessment between patients and physicians. Four patients (9.5%) experienced a local failure and underwent salvage mastectomy. The 5 year-disease free survival is 92.7% (range 79.1−97.6). All patients are still alive with a median follow-up of 72 months (range 66–74). Conclusion Our results confirm with a long-term follow-up that exclusive partial breast IORT is feasible for early-breast cancer in selected patients. IORT provides good late cosmetics results and should be considered as a safe and very comfortable “one-step” treatment procedure. Nevertheless, patient assessments are essential for long-term quality results. PMID:23902825
Lenarczyk, Radoslaw; Potpara, Tatjana S; Haugaa, Kristina H; Deharo, Jean-Claude; Hernandez-Madrid, Antonio; Del Carmen Exposito Pineda, Maria; Kiliszek, Marek; Dagres, Nikolaos
2017-09-01
The aim of this European Heart Rhythm Association (EHRA) survey was to evaluate clinical practice regarding cardio-oncologic patients, with special focus on patients with cardiac implantable electronic devices (CIEDs) planned for anticancer radiotherapy (RT), among members of the EHRA electrophysiology research network. Of the 36 responding centres, 89% managed patients who were diagnosed or treated oncologically, and this diagnosis affected 1-5% of cardiovascular patients in majority of centres (57%). The main side effects of anticancer therapy in patients treated by cardiologists were thromboembolic complications and left ventricular dysfunction (both reported as 'frequent' by 43% of the centres). The main agents associated with complications were anthracyclines, RT, and monoclonal antibodies. Echocardiography was the most common method of screening for cardiovascular complications (93%), and 10% of the centres did not routinely screen for treatment-induced cardiotoxicity. Opinions on the safe radiation dose, methods of device shielding, and risk calculation prior to RT in CIED patients differed among centres. Precaution measures in high-risk CIED patients were very heterogeneous among centres. Our survey has shown that the awareness of cardiac consequences of anticancer therapy is high, despite relatively low proportion of patients treated oncologically among all cardiovascular patients. There is a consensus of which screening methods should be used for cardiotoxicity of anticancer treatment, but the apprehension of screening necessity is low. Methods of risk assessment and safety measures in CIED patients undergoing RT are very heterogeneous among the European centres, underscoring the need for standardization of the approach to cardio-oncologic patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.
Datta, Niloy Ranjan; Khan, Shaka; Marder, Dietmar; Zwahlen, Daniel; Bodis, Stephan
2016-09-01
The purpose of this study was to evaluate the present status of radiotherapy infrastructure and human resources in Switzerland and compute projections for 2020. The European Society of Therapeutic Radiation Oncology "Quantification of Radiation Therapy Infrastructure and Staffing" guidelines (ESTRO-QUARTS) and those of the International Atomic Energy Agency (IAEA) were applied to estimate the requirements for teleradiotherapy (TRT) units, radiation oncologists (RO), medical physicists (MP) and radiotherapy technologists (RTT). The databases used for computation of the present gap and additional requirements are (a) Global Cancer Incidence, Mortality and Prevalence (GLOBOCAN) for cancer incidence (b) the Directory of Radiotherapy Centres (DIRAC) of the IAEA for existing TRT units (c) human resources from the recent ESTRO "Health Economics in Radiation Oncology" (HERO) survey and (d) radiotherapy utilization (RTU) rates for each tumour site, published by the Ingham Institute for Applied Medical Research (IIAMR). In 2015, 30,999 of 45,903 cancer patients would have required radiotherapy. By 2020, this will have increased to 34,041 of 50,427 cancer patients. Switzerland presently has an adequate number of TRTs, but a deficit of 57 ROs, 14 MPs and 36 RTTs. By 2020, an additional 7 TRTs, 72 ROs, 22 MPs and 66 RTTs will be required. In addition, a realistic dynamic model for calculation of staff requirements due to anticipated changes in future radiotherapy practices has been proposed. This model could be tailor-made and individualized for any radiotherapy centre. A 9.8 % increase in radiotherapy requirements is expected for cancer patients over the next 5 years. The present study should assist the stakeholders and health planners in designing an appropriate strategy for meeting future radiotherapy needs for Switzerland.
Prognostic Factors Affecting Locally Recurrent Rectal Cancer and Clinical Significance of Hemoglobin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rades, Dirk; Kuhn, Hildegard; Schultze, Juergen
2008-03-15
Purpose: To investigate potential prognostic factors, including hemoglobin levels before and during radiotherapy, for associations with survival and local control in patients with unirradiated locally recurrent rectal cancer. Patients and Methods: Ten potential prognostic factors were investigated in 94 patients receiving radiotherapy for recurrent rectal cancer: age ({<=}68 vs. {>=}69 years), gender, Eastern Cooperative Oncology Group performance status (0-1 vs. 2-3), American Joint Committee on Cancer (AJCC) stage ({<=}II vs. III vs. IV), grading (G1-2 vs. G3), surgery, administration of chemotherapy, radiation dose (equivalent dose in 2-Gy fractions: {<=}50 vs. >50 Gy), and hemoglobin levels before (<12 vs. {>=}12 g/dL)more » and during (majority of levels: <12 vs. {>=}12 g/dL) radiotherapy. Multivariate analyses were performed, including hemoglobin levels, either before or during radiotherapy (not both) because these are confounding variables. Results: Improved survival was associated with better performance status (p < 0.001), lower AJCC stage (p = 0.023), surgery (p = 0.011), chemotherapy (p = 0.003), and hemoglobin levels {>=}12 g/dL both before (p = 0.031) and during (p < 0.001) radiotherapy. On multivariate analyses, performance status, AJCC stage, and hemoglobin levels during radiotherapy maintained significance. Improved local control was associated with better performance status (p = 0.040), lower AJCC stage (p = 0.010), lower grading (p = 0.012), surgery (p < 0.001), chemotherapy (p < 0.001), and hemoglobin levels {>=}12 g/dL before (p < 0.001) and during (p < 0.001) radiotherapy. On multivariate analyses, chemotherapy, grading, and hemoglobin levels before and during radiotherapy remained significant. Subgroup analyses of the patients having surgery demonstrated the extent of resection to be significantly associated with local control (p = 0.011) but not with survival (p = 0.45). Conclusion: Predictors for outcome in patients who received radiotherapy for locally recurrent rectal cancer were performance status, AJCC stage, chemotherapy, surgery, extent of resection, histologic grading, and hemoglobin levels both before and during radiotherapy.« less
Stoker, Sharon D; Wildeman, Maarten A; Fles, Renske; Indrasari, Sagung R; Herdini, Camelia; Wildeman, Pieter L; van Diessen, Judi N A; Tjokronagoro, Maesadji; Tan, I Bing
2014-01-01
Nasopharyngeal carcinoma (NPC) has a high incidence in Indonesia. Previous study in Yogyakarta revealed a complete response of 29% and a median overall survival of less than 2 years. These poor treatment outcome are influenced by the long diagnose-to-treatment interval to radiotherapy (DTI) and the extended overall treatment time of radiotherapy (OTT). This study reveals insight why the OTT and DTI are prolonged. All patients treated with curative intent radiotherapy for NPC between July 2011 until October 2012 were included. During radiotherapy a daily diary was kept, containing information on DTI, missed radiotherapy days, the reason for missing and length of OTT. Sixty-eight patients were included. The median DTI was 106 days (95% CI: 98-170). Fifty-nine patients (87%) finished the treatment. The median OTT for radiotherapy was 57 days (95% CI: 57-65). The main reason for missing days was an inoperative radiotherapy machine (36%). Other reasons were patient's poor condition (21%), public holidays (14%), adjustment of the radiation field (7%), power blackout (3%), inoperative treatment planning system (2%) and patient related reasons (9%). Patient's insurance type was correlated to DTI in disadvantage for poor people. Yogyakarta has a lack of sufficient radiotherapy units which causes a delay of 3-4 months, besides the OTT is extended by 10-12 days. This influences treatment outcome to a great extend. The best solution would be creating sufficient radiotherapy units and better management in health care for poor patients. The growing economy in Indonesia will expectantly in time enable these solutions, but in the meantime solutions are needed. Solutions can consist of radiation outside office hours, better maintenance of the facilities and more effort from patient, doctor and nurse to finish treatment in time. These results are valuable when improving cancer care in low and middle income countries.
Vyas, Purvi; Thakar, A B; Baghel, M S; Sisodia, Arvind; Deole, Yogesh
2010-10-01
Cancer is the most dreadful disease affecting mankind. The available treatments such as chemotherapy and radiotherapy have cytotoxic effects, which are hazardous to the normal cells of the patient, causing many unnecessary effects. This further leads to complications of the therapy, impaired health, and deterioration of quality of life, resulting in mandatory stoppage of the treatment. In the present study, the efficacy of an Ayurvedic formulation, Rasayana Avaleha, has been evaluated as an adjuvant medication to modern radiotherapy and chemotherapy. A total of 36 cancer patients were registered in this trial and were divided into two groups, group A and group B. In group A, the patients were treated with radiotherapy and chemotherapy along with adjuvant Rasayana Avaleha (RT + CT + RA), while in group B only radiotherapy and chemotherapy (RT + CT) were given, as the control group. After assessing the results, it was observed that Rasayana Avaleha gave better results in controlling the adverse effect of chemotherapy and radiotherapy in comparison with the control group. Therefore, Rasayana Avaleha has proved to be an effective adjuvant therapy in protecting patients from the adverse effects of chemotherapy and radiotherapy.
Radiation-induced heart disease in lung cancer radiotherapy
Ming, Xin; Feng, Yuanming; Yang, Chengwen; Wang, Wei; Wang, Ping; Deng, Jun
2016-01-01
Abstract Background: Radiation-induced heart disease (RIHD), which affects the patients’ prognosis with both acute and late side effects, has been published extensively in the radiotherapy of breast cancer, lymphoma and other benign diseases. Studies on RIHD in lung cancer radiotherapy, however, are less extensive and clear even though the patients with lung cancer are delivered with higher doses to the heart during radiation treatment. Methods: In this article, after extensive literature search and analysis, we reviewed the current evidence on RIHD in lung cancer patients after their radiation treatments and investigated the potential risk factors for RIHD as compared to other types of cancers. Result: Cardiac toxicity has been found highly relevant in lung cancer radiotherapy. So far, the crude incidence of cardiac complications in the lung cancer patients after radiotherapy has been up to 33%. Conclusion: The dose to the heart, the lobar location of tumor, the treatment modality, the history of heart and pulmonary disease and smoking were considered as potential risk factors for RIHD in lung cancer radiotherapy. As treatment techniques improve over the time with better prognosis for lung cancer survivors, an improved prediction model can be established to further reduce the cardiac toxicity in lung cancer radiotherapy. PMID:27741117
Radiation-induced heart disease in lung cancer radiotherapy: A dosimetric update.
Ming, Xin; Feng, Yuanming; Yang, Chengwen; Wang, Wei; Wang, Ping; Deng, Jun
2016-10-01
Radiation-induced heart disease (RIHD), which affects the patients' prognosis with both acute and late side effects, has been published extensively in the radiotherapy of breast cancer, lymphoma and other benign diseases. Studies on RIHD in lung cancer radiotherapy, however, are less extensive and clear even though the patients with lung cancer are delivered with higher doses to the heart during radiation treatment. In this article, after extensive literature search and analysis, we reviewed the current evidence on RIHD in lung cancer patients after their radiation treatments and investigated the potential risk factors for RIHD as compared to other types of cancers. Cardiac toxicity has been found highly relevant in lung cancer radiotherapy. So far, the crude incidence of cardiac complications in the lung cancer patients after radiotherapy has been up to 33%. The dose to the heart, the lobar location of tumor, the treatment modality, the history of heart and pulmonary disease and smoking were considered as potential risk factors for RIHD in lung cancer radiotherapy. As treatment techniques improve over the time with better prognosis for lung cancer survivors, an improved prediction model can be established to further reduce the cardiac toxicity in lung cancer radiotherapy.
Recent advances in intensity modulated radiotherapy and proton therapy for esophageal cancer.
Xi, Mian; Lin, Steven H
2017-07-01
Radiotherapy is an important component of the standard of care for esophageal cancer. In the past decades, significant improvements in the planning and delivery of radiation techniques have led to better dose conformity to the target volume and improved normal tissue sparing. Areas covered: This review focuses on the advances in radiotherapy techniques and summarizes the availably dosimetric and clinical outcomes of intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, proton therapy, and four-dimensional radiotherapy for esophageal cancer, and discusses the challenges and future development of proton therapy. Expert commentary: Although three-dimensional conformal radiotherapy is the standard radiotherapy technique in esophageal cancer, the retrospectively comparative studies strongly suggest that the dosimetric advantage of IMRT over three-dimensional conformal radiotherapy can translate into improved clinical outcomes, despite the lack of prospective randomized evidence. As a novel form of conventional IMRT technique, volumetric modulated arc therapy can produce equivalent or superior dosimetric quality with significantly higher treatment efficiency in esophageal cancer. Compared with photon therapy, proton therapy has the potential to achieve further clinical improvement due to their physical properties; however, prospective clinical data, long-term results, and cost-effectiveness are needed.
Polf, Jerimy C.; Bronk, Lawrence F.; Driessen, Wouter H. P.; Arap, Wadih; Pasqualini, Renata; Gillin, Michael
2011-01-01
The development and use of sensitizing agents to improve the effectiveness of radiotherapy have long been sought to improve our ability to treat cancer. In this letter, we have studied the relative biological effectiveness of proton beam radiotherapy on prostate tumor cells with and without internalized gold nanoparticles. The effectiveness of proton radiotherapy for the killing of prostate tumor cells was increased by approximately 15%–20% for those cells containing internalized gold nanoparticles. PMID:21915155
The development of stereotactic body radiotherapy in the past decade: a global perspective.
Lo, Simon S; Slotman, Ben J; Lock, Michael; Nagata, Yasushi; Guckenberger, Matthias; Siva, Shankar; Foote, Matthew; Tan, Daniel; Teh, Bin S; Mayr, Nina A; Chang, Eric L; Timmerman, Robert D; Sahgal, Arjun
2015-09-04
In the past 10 years, there has been an exponential increase in the incorporation of stereotactic body radiotherapy, also known as stereotactic ablative radiotherapy, into the armamentarium against various types of cancer in different settings worldwide. In this article in the 10th year anniversary issue of Future Oncology, representatives from the USA, Canada, Japan, Germany, The Netherlands, Australia and Singapore will provide individual perspectives of the development of stereotactic body radiotherapy in their respective countries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moser, Elizabeth C.; Kluin-Nelemans, Hanneke C.; Carde, Patrice
2006-11-15
Purpose: Whether salvage therapy in patients with advanced aggressive non-Hodgkin's lymphoma (NHL) in partial remission (PR) should consist of radiotherapy or autologous stem-cell transplantation (ASCT) is debatable. We evaluated the impact of radiotherapy on outcome in PR patients treated in four successive European Organization for Research and Treatment of Cancer trials for aggressive NHL. Patients and Methods: Records of 974 patients (1980-1999) were reviewed regarding initial response, final outcome, and type and timing of salvage treatment. After 8 cycles of doxorubicin-based chemotherapy, 227 NHL patients were in PR and treated: 114 received involved field radiotherapy, 16 ASCT, 93 second-line chemotherapy,more » and 4 were operated. Overall survival (OS) and progression-free survival (PFS) after radiotherapy were estimated (Kaplan-Meier method) and compared with other treatments (log-rank). Impact on survival was evaluated by multivariate analysis (Cox proportional hazards model). Results: The median PFS in PR patients was 4.2 years and 48% remained progression-free at 5 years. Half of the PR patients converted to a complete remission. After conversion, survival was comparable to patients directly in complete remission. Radiotherapy resulted in better OS and PFS compared with other treatments, especially in patients with low to intermediate International Prognostic Index score, bulky disease, or nodal disease only. Correction by multivariate analysis for prognostic factors such as stage, bulky disease, and number of extranodal locations showed that radiotherapy was clearly the most significant factor affecting both OS and PFS. Conclusion: This retrospective analysis demonstrates that radiotherapy can be effective for patients in PR after fully dosed chemotherapy; assessment in a randomized trial (radiotherapy vs. ASCT) is justified.« less
Jereczek-Fossa, Barbara Alicja; Colangione, Sarah Pia; Fodor, Cristiana; Russo, Stefania; Cambria, Raffaella; Zerini, Dario; Bonora, Maria; Cecconi, Agnese; Vischioni, Barbara; Vavassori, Andrea; Matei, Deliu Victor; Bottero, Danilo; Brescia, Antonio; Musi, Gennaro; Mazzoleni, Federica; Orsi, Franco; Bonomo, Guido; De Cobelli, Ottavio; Orecchia, Roberto
2015-08-01
The purpose of the study was to evaluate the feasibility of irradiation after prostatectomy in the presence of asymptomatic pelvic lymphocele. The inclusion criteria for this study were: (1) patients referred for postoperative (adjuvant or salvage) intensity modulated radiotherapy (IMRT; 66-69 Gy in 30 fractions); (2) detection of postoperative pelvic lymphocele at the simulation computed tomography [CT] scan; (3) no clinical symptoms; and (4) written informed consent. Radiotherapy toxicity and occurrence of symptoms or complications of lymphocele were analyzed. Dosimetric data (IMRT plans) and the modification of lymphocele volume during radiotherapy (cone beam CT [CBCT] scan) were evaluated. Between January 2011 and July 2013, in 30 of 308 patients (10%) treated with radiotherapy after prostatectomy, pelvic lymphocele was detected on the simulation CT. The median lymphocele volume was 47 cm(3) (range, 6-467.3 cm(3)). Lymphocele was not included in planning target volume (PTV) in 8 cases (27%). Maximum dose to lymphocele was 57 Gy (range, 5.7-73.3 Gy). Radiotherapy was well tolerated. In all but 2 patients, lymphoceles remained asymptomatic. Lymphocele drainage-because of symptom occurrence-had to be performed in 2 patients during IMRT and in one patient, 7 weeks after IMRT. CBCT at the end of IMRT showed reduction in lymphocele volume and position compared with the initial data (median reduction of 37%), more pronounced in lymphoceles included in PTV. Radiotherapy after prostatectomy in the presence of pelvic asymptomatic lymphocele is feasible with acceptable acute and late toxicity. The volume of lymphoceles decreased during radiotherapy and this phenomenon might require intermediate radiotherapy plan evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.
Jacobs, Maria; Boersma, Liesbeth; Dekker, Andre; Swart, Rachelle; Lambin, Philippe; de Ruysscher, Dirk; Verhaegen, Frank; Stultiens, Joost; Ramaekers, Bram; van Merode, Frits
2017-11-01
To analyse how often innovations in healthcare are evaluated regarding output, especially in radiotherapy. Output was defined as either survival, toxicity, safety, service, efficiency or cost-effectiveness. A systematic literature review was conducted, using three search strategies: (1) innovations in general healthcare; (2) radiotherapy-specific innovations, i.e. organizational innovations and general implementation of innovations; (3) innovations per tumour group/radiotherapy technique. Scientific levels were classified according to the system used in European Society for Medical Oncology guidelines. Finally, we calculated the percentage of implemented innovations in Dutch radiotherapy centres for which we found evidence regarding output in the literature review. Only 94/1072 unique articles matched the inclusion criteria. Significant results on patient outcome, service or safety were reported in 65% of papers, which rose to 76% if confined to radiotherapy reviews. A significant technological improvement was identified in 26%, cost-effectiveness in 10% and costs/efficiency in 36% of the papers. The scientific level of organizational innovations was lower than that of clinical papers. Dutch radiotherapy treatment innovations were adequately evaluated on outcome data before implementation in clinical routine in a minimum of 64-92% of cases. Only few studies report on output when considering innovations in general, but radiotherapy reviews give a reasonably good insight into innovation output effects, with a higher level of evidence. In Dutch radiotherapy centres only small improvements are possible regarding evaluation of treatment innovations before implementation. Advances in knowledge: This study is the first of its kind measuring how innovations are evaluated in scientific literature, before implementation in clinical practice.
Windsor, Phyllis M; Nicol, Kathleen F; Potter, Joan
2004-08-01
Advice to rest and take things easy if patients become fatigued during radiotherapy may be detrimental. Aerobic walking improves physical functioning and has been an intervention for chemotherapy-related fatigue. A prospective, randomized, controlled trial was performed to determine whether aerobic exercise would reduce the incidence of fatigue and prevent deterioration in physical functioning during radiotherapy for localized prostate carcinoma. Sixty-six men were randomized before they received radical radiotherapy for localized prostate carcinoma, with 33 men randomized to an exercise group and 33 men randomized to a control group. Outcome measures were fatigue and distance walked in a modified shuttle test before and after radiotherapy. There were no significant between group differences noted with regard to fatigue scores at baseline (P = 0.55) or after 4 weeks of radiotherapy (P = 0.18). Men in the control group had significant increases in fatigue scores from baseline to the end of radiotherapy (P = 0.013), with no significant increases observed in the exercise group (P = 0.203). A nonsignificant reduction (2.4%) in shuttle test distance at the end of radiotherapy was observed in the control group; however, in the exercise group, there was a significant increase (13.2%) in distance walked (P = 0.0003). Men who followed advice to rest and take things easy if they became fatigued demonstrated a slight deterioration in physical functioning and a significant increase in fatigue at the end of radiotherapy. Home-based, moderate-intensity walking produced a significant improvement in physical functioning with no significant increase in fatigue. Improved physical functioning may be necessary to combat radiation fatigue.
Intensity-Modulated Radiotherapy for Cervical Lymph Node Metastases From Unknown Primary Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madani, Indira; Vakaet, Luc; Bonte, Katrien
2008-07-15
Purpose: To compare the effectiveness of intensity-modulated radiotherapy (IMRT) and conventional (two-dimensional) radiotherapy in the treatment of cervical lymph node metastases from unknown primary cancer (UPC). Methods and Materials: Between February 2003 and September 2006, 23 patients with UPC of squamous cell carcinoma were treated with IMRT. Extended putative mucosal and bilateral nodal sites were irradiated to a median dose of 66 Gy. In 19 patients, IMRT was performed after lymph node dissection, and in 4 patients primary radiotherapy was given. The conventional radiotherapy group (historical control group) comprised 18 patients treated to a median dose of 66 Gy betweenmore » August 1994 and October 2003. Results: Twenty patients completed treatment. As compared with conventional radiotherapy, the incidence of Grade 3 acute dysphagia was significantly lower in the IMRT group (4.5% vs. 50%, p = 0.003). By 6 months, Grade 3 xerostomia was detected in 11.8% patients in the IMRT group vs. 53.4% in the historical control group (p = 0.03). No Grade 3 dysphagia or skin fibrosis was observed after IMRT but these were noted after conventional radiotherapy (26.7%, p = 0.01) and 26.7%, p = 0.03) respectively). With median follow-up of living patients of 17 months, there was no emergence of primary cancer. One patient had persistent nodal disease and another had nodal relapse at 5 months. Distant metastases were detected in 4 patients. The 2-year overall survival and distant disease-free probability after IMRT did not differ significantly from those for conventional radiotherapy (74.8% vs. 61.1% and 76.3% vs. 68.4%, respectively). Conclusions: Use of IMRT for UPC resulted in lower toxicity than conventional radiotherapy, and was similar in efficacy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choe, Kevin S.; Jani, Ashesh B.; Liauw, Stanley L., E-mail: sliauw@radonc.uchicago.ed
Purpose: To characterize the bleeding toxicity associated with external beam radiotherapy for prostate cancer patients receiving anticoagulation (AC) therapy. Methods and Materials: The study cohort consisted of 568 patients with adenocarcinoma of the prostate who were treated with definitive external beam radiotherapy. Of these men, 79 were receiving AC therapy with either warfarin or clopidogrel. All patients were treated with three-dimensional conformal radiotherapy or intensity-modulated radiotherapy. Bleeding complications were recorded during treatment and subsequent follow-up visits. Results: With a median follow-up of 48 months, the 4-year actuarial risk of Grade 3 or worse bleeding toxicity was 15.5% for those receivingmore » AC therapy compared with 3.6% among those not receiving AC (p < .0001). On multivariate analysis, AC therapy was the only significant factor associated with Grade 3 or worse bleeding (p < .0001). For patients taking AC therapy, the crude rate of bleeding was 39.2%. Multivariate analysis within the AC group demonstrated that a higher radiotherapy dose (p = .0408), intensity-modulated radiotherapy (p = 0.0136), and previous transurethral resection of the prostate (p = .0001) were associated with Grade 2 or worse bleeding toxicity. Androgen deprivation therapy was protective against bleeding, with borderline significance (p = 0.0599). Dose-volume histogram analysis revealed that Grade 3 or worse bleeding was minimized if the percentage of the rectum receiving >=70 Gy was <10% or the rectum receiving >=50 Gy was <50%. Conclusion: Patients taking AC therapy have a substantial risk of bleeding toxicity from external beam radiotherapy. In this setting, dose escalation or intensity-modulated radiotherapy should be used judiciously. With adherence to strict dose-volume histogram criteria and minimizing hotspots, the risk of severe bleeding might be reduced.« less
How to use PET/CT in the evaluation of response to radiotherapy.
Decazes, Pierre; Thureau, Sébastien; Dubray, Bernard; Vera, Pierre
2018-06-01
Radiotherapy is a major treatment modality for many cancers. Tumor response after radiotherapy determines the subsequent steps of the patient's management (surveillance, adjuvant or salvage treatment and palliative care). Tumor response assessed during radiotherapy offers a promising opportunity to adapt the treatment plan to reduced or increased target volume, to specifically target sub-volumes with relevant biological characteristics (metabolism, hypoxia, proliferation, etc.) and to further spare the organs at risk. In addition to its role in the diagnosis and the initial staging, Positron Emission Tomography combined with a Computed Tomography (PET/CT) provides functional information and is therefore attractive to evaluate tumor response. The aim of this paper is to review the published data addressing PET/CT as an evaluation tool in irradiated tumors. Reports on PET/CT acquired at various times (during radiotherapy, after initial (chemo-) radiotherapy, after definitive radiotherapy and during posttreatment follow-up) in solid tumors (lung, head-and-neck, cervix, esophagus, prostate and rectum) were collected and reviewed. Various tracers and technical aspects are also discussed. 18F-FDG PET/CT has a well-established role in clinical routine after definitive chemo-radiotherapy for locally advanced head-and-neck cancers. 18F-choline PET/CT is indicated in prostate cancer patients with biochemical failure. 18F-FDG PET/CT is optional in many other circumstances and the clinical benefits of assessing tumor response with PET/CT remain a field of very active research. The combination of PET with Magnetic Resonance Imaging (PET/MRI) may prove to be valuable in irradiated rectal and cervix cancers. Tumor response can be evaluated by PET/CT with clinical consequences in multiple situations, notably in head and neck and prostate cancers, after radiotherapy. Further clinical evaluation for most cancers is still needed, possibly in association to MRI.
Risk of ischemic heart disease in women after radiotherapy for breast cancer.
Darby, Sarah C; Ewertz, Marianne; McGale, Paul; Bennet, Anna M; Blom-Goldman, Ulla; Brønnum, Dorthe; Correa, Candace; Cutter, David; Gagliardi, Giovanna; Gigante, Bruna; Jensen, Maj-Britt; Nisbet, Andrew; Peto, Richard; Rahimi, Kazem; Taylor, Carolyn; Hall, Per
2013-03-14
Radiotherapy for breast cancer often involves some incidental exposure of the heart to ionizing radiation. The effect of this exposure on the subsequent risk of ischemic heart disease is uncertain. We conducted a population-based case-control study of major coronary events (i.e., myocardial infarction, coronary revascularization, or death from ischemic heart disease) in 2168 women who underwent radiotherapy for breast cancer between 1958 and 2001 in Sweden and Denmark; the study included 963 women with major coronary events and 1205 controls. Individual patient information was obtained from hospital records. For each woman, the mean radiation doses to the whole heart and to the left anterior descending coronary artery were estimated from her radiotherapy chart. The overall average of the mean doses to the whole heart was 4.9 Gy (range, 0.03 to 27.72). Rates of major coronary events increased linearly with the mean dose to the heart by 7.4% per gray (95% confidence interval, 2.9 to 14.5; P<0.001), with no apparent threshold. The increase started within the first 5 years after radiotherapy and continued into the third decade after radiotherapy. The proportional increase in the rate of major coronary events per gray was similar in women with and women without cardiac risk factors at the time of radiotherapy. Exposure of the heart to ionizing radiation during radiotherapy for breast cancer increases the subsequent rate of ischemic heart disease. The increase is proportional to the mean dose to the heart, begins within a few years after exposure, and continues for at least 20 years. Women with preexisting cardiac risk factors have greater absolute increases in risk from radiotherapy than other women. (Funded by Cancer Research UK and others.).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Macchia, Gabriella, E-mail: gmacchia@rm.unicatt.i; Cilla, Savino M.P.; Ferrandina, Gabriella
2010-04-15
Purpose: To determine the maximum tolerated dose of short-course radiotherapy (intensity-modulated radiotherapy technique) to the upper two thirds of the vagina in endometrial cancers with low risk of local recurrence. Patients and Methods: A Phase I clinical trial was performed. Eligible patients had low-risk resected primary endometrial adenocarcinomas. Radiotherapy was delivered in 5 fractions over 1 week. The planning target volume was the clinical target volume plus 5 mm. The clinical target volume was defined as the upper two thirds of the vagina as evidenced at CT simulation by a vaginal radio-opaque device. The planning target volume was irradiated bymore » a seven-field intensity-modulated radiotherapy technique, planned by the Plato Sunrise inverse planning system. A first cohort of 6 patients received 25 Gy (5-Gy fractions), and a subsequent cohort received 30 Gy (6-Gy fractions). The Common Toxicity Criteria scale, version 3.0, was used to score toxicity. Results: Twelve patients with endometrial cancer were enrolled. Median age was 58 years (range, 49-74 years). Pathologic stage was IB (83.3%) and IC (16.7%). Median tumor size was 30 mm (range, 15-50 mm). All patients completed the prescribed radiotherapy. No patient experienced a dose-limiting toxicity at the first level, and the radiotherapy dose was escalated from 25 to 30 Gy. No patients at the second dose level experienced dose-limiting toxicity. The most common Grade 2 toxicity was gastrointestinal, which was tolerable and manageable. Conclusions: The maximum tolerated dose of short-course radiotherapy was 30 Gy at 6 Gy per fraction. On the basis of this result, we are conducting a Phase II study with radiotherapy delivered at 30 Gy.« less
Cui, Yi; Li, Bailiang; Pollom, Erqi Liu; Horst, Kathleen; Li, Ruijiang
2018-06-19
Breast cancer is a heterogeneous disease and not all patients respond equally to adjuvant radiotherapy. Predictive biomarkers are needed to select patients who will benefit from the treatment and spare others the toxicity and burden of radiation. We first trained and tested an intrinsic radiosensitivity gene signature to predict local recurrence after radiotherapy in three cohorts of 948 patients. Next, we developed an antigen processing and presentation-based immune signature by maximizing the treatment interaction effect in 129 patients. To test their predictive value, we matched patients treated with or without radiotherapy in an independent validation cohort for clinicopathologic factors including age, ER status, HER2 status, stage, hormone-therapy, chemotherapy, and surgery. Disease specific survival (DSS) was the primary endpoint. Our validation cohort consisted of 1,439 patients. After matching and stratification by the radiosensitivity signature, patients who received radiotherapy had better DSS than patients who did not in the radiation-sensitive group (hazard ratio [HR]=0.68, P=0.059, n=322), while a reverse trend was observed in the radiation-resistant group (HR=1.53, P=0.059, n=202). Similarly, patients treated with radiotherapy had significantly better DSS in the immuneeffective group (HR=0.46, P=0.0076, n=180), with no difference in DSS in the immunedefective group (HR=1.27, P=0.16, n=348). Both signatures were predictive of radiotherapy benefit (P interaction =0.007 and 0.005). Integration of radiosensitivity and immune signatures further stratified patients into three groups with differential outcomes for those treated with or without radiotherapy (P interaction =0.003). The proposed signatures have the potential to select patients who are most likely to benefit from radiotherapy. Copyright ©2018, American Association for Cancer Research.
History of the development of radiotherapy in Latin America.
Pinillos, Luis; Pinto, Joseph A; Sarria, Gustavo
2017-01-01
Radiotherapy was the first nonsurgical treatment for malignant tumours and represents one of the oldest disciplines of oncology. In Latin America, as in many parts of the world, the history of modern oncology begins with the implementation of radiation therapy facilities. The development of radiotherapy in Latin America was possible thanks to the seminal work of radiation oncologists in different countries. As a large territory, there is a need to implement modern facilities and equipment, but unfortunately there are disparities in the access and quality of radiotherapy services across Latin America and even within individual countries. In this review, we describe the history, challenges and success in the implementation of radiotherapy and the frustration caused by the lack of facilities in several Latin American countries.
Comparison of measured electron energy spectra for six matched, radiotherapy accelerators.
McLaughlin, David J; Hogstrom, Kenneth R; Neck, Daniel W; Gibbons, John P
2018-05-01
This study compares energy spectra of the multiple electron beams of individual radiotherapy machines, as well as the sets of spectra across multiple matched machines. Also, energy spectrum metrics are compared with central-axis percent depth-dose (PDD) metrics. A lightweight, permanent magnet spectrometer was used to measure energy spectra for seven electron beams (7-20 MeV) on six matched Elekta Infinity accelerators with the MLCi2 treatment head. PDD measurements in the distal falloff region provided R 50 and R 80-20 metrics in Plastic Water ® , which correlated with energy spectrum metrics, peak mean energy (PME) and full-width at half maximum (FWHM). Visual inspection of energy spectra and their metrics showed whether beams on single machines were properly tuned, i.e., FWHM is expected to increase and peak height decrease monotonically with increased PME. Also, PME spacings are expected to be approximately equal for 7-13 MeV beams (0.5-cm R 90 spacing) and for 13-16 MeV beams (1.0-cm R 90 spacing). Most machines failed these expectations, presumably due to tolerances for initial beam matching (0.05 cm in R 90 ; 0.10 cm in R 80-20 ) and ongoing quality assurance (0.2 cm in R 50 ). Also, comparison of energy spectra or metrics for a single beam energy (six machines) showed outlying spectra. These variations in energy spectra provided ample data spread for correlating PME and FWHM with PDD metrics. Least-squares fits showed that R 50 and R 80-20 varied linearly and supralinearly with PME, respectively; however, both suggested a secondary dependence on FWHM. Hence, PME and FWHM could serve as surrogates for R 50 and R 80-20 for beam tuning by the accelerator engineer, possibly being more sensitive (e.g., 0.1 cm in R 80-20 corresponded to 2.0 MeV in FWHM). Results of this study suggest a lightweight, permanent magnet spectrometer could be a useful beam-tuning instrument for the accelerator engineer to (a) match electron beams prior to beam commissioning, (b) tune electron beams for the duration of their clinical use, and (c) provide estimates of PDD metrics following machine maintenance. However, a real-time version of the spectrometer is needed to be practical. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Monte Carlo dose distribution calculation at nuclear level for Auger-emitting radionuclide energies.
Di Maria, S; Belchior, A; Romanets, Y; Paulo, A; Vaz, P
2018-05-01
The distribution of radiopharmaceuticals in tumor cells represents a fundamental aspect for a successful molecular targeted radiotherapy. It was largely demonstrated at microscopic level that only a fraction of cells in tumoral tissues incorporate the radiolabel. In addition, the distribution of the radionuclides at sub-cellular level, namely inside each nucleus, should also be investigated for accurate dosimetry estimation. The most used method to perform cellular dosimetry is the MIRD one, where S-values are able to estimate cellular absorbed doses for several electron energies, nucleus diameters, and considering homogeneous source distributions. However the radionuclide distribution inside nuclei can be also highly non-homogeneous. The aim of this study is to show in what extent a non-accurate cellular dosimetry could lead to misinterpretations of surviving cell fraction vs dose relationship; in this context, a dosimetric case study with 99m Tc is also presented. The state-of-art MCNP6 Monte Carlo simulation was used in order to model cell structures both in MIRD geometry (MG) and MIRD modified geometries (MMG), where also entire mitotic chromosome volumes were considered (each structure was modeled as liquid water material). In order to simulate a wide energy range of Auger emitting radionuclides, four mono energetic electron emissions were considered, namely 213eV, 6keV, 11keV and 20keV. A dosimetric calculation for 99m Tc undergoing inhomogeneous nuclear internalization was also performed. After a successful validation step between MIRD and our computed S-values for three Auger-emitting radionuclides ( 99m Tc, 125 I and 64 Cu), absorbed dose results showed that the standard MG could differ from the MMG from one to three orders of magnitude. These results were also confirmed by considering the 99m Tc spectrum emission (Auger and internal conversion electrons). Moreover, considering an inhomogeneous radionuclide distribution, the average electron energy that maximizes the absorbed dose was found to be different for MG and MMG. The modeling of realistic radionuclide localization inside cells, including a inhomogeneous nuclear distribution, revealed that i) a strong bias in surviving cell fraction vs dose relationships (taking to different radiobiological models) can arise; ii) the alternative models might contribute to a more accurate prediction of the radiobiological effects inherent to more specific molecular targeted radiotherapy strategies. Copyright © 2018 Elsevier Ltd. All rights reserved.
Survey on deep learning for radiotherapy.
Meyer, Philippe; Noblet, Vincent; Mazzara, Christophe; Lallement, Alex
2018-07-01
More than 50% of cancer patients are treated with radiotherapy, either exclusively or in combination with other methods. The planning and delivery of radiotherapy treatment is a complex process, but can now be greatly facilitated by artificial intelligence technology. Deep learning is the fastest-growing field in artificial intelligence and has been successfully used in recent years in many domains, including medicine. In this article, we first explain the concept of deep learning, addressing it in the broader context of machine learning. The most common network architectures are presented, with a more specific focus on convolutional neural networks. We then present a review of the published works on deep learning methods that can be applied to radiotherapy, which are classified into seven categories related to the patient workflow, and can provide some insights of potential future applications. We have attempted to make this paper accessible to both radiotherapy and deep learning communities, and hope that it will inspire new collaborations between these two communities to develop dedicated radiotherapy applications. Copyright © 2018 Elsevier Ltd. All rights reserved.
[Description of latest generation equipment in external radiotherapy].
Pellejero, S; Lozares, S; Mañeru, F
2009-01-01
Both the planning systems and the form of administering radiotherapy have changed radically since the introduction of 3D planning. At present treatment planning based on computerised axial tomography (CAT) images is standard practice in radiotherapy services. In recent years lineal accelerators for medical use have incorporated technology capable of administering intensity modulated radiation beams (IMRT). With this mode distributions of conformed doses are generated that adjust to the three dimensional form of the white volume, providing appropriate coverage and a lower dose to nearby risk organs. The use of IMRT is rapidly spreading amongst radiotherapy centres throughout the world. This growing use of IMRT has focused attention on the need for greater control of the geometric uncertainties in positioning the patient and control of internal movements. To this end, both flat and volumetric image systems have been incorporated into the treatment equipment, making image-guided radiotherapy (IGRT) possible. This article offers a brief description of the latest advances included in the planning and administration of radiotherapy treatment.
The launch of the first UK charity devoted to radiotherapy: ACORRN -- Action Radiotherapy.
Price, P
2011-01-01
The Academic Clinical Oncology and Radiobiology Research Network (ACORRN) was set up to support research and development in radiotherapy in the UK. This innovative networking initiative was launched initially by the National Cancer Research Institute in 2005 to harness the power of the radiation research base in the UK. Through an interactive website a co-ordinated network of multidisciplinary radiation researchers has been established. The network has developed to a stage where it can be self-funding and dedicated to improving radiotherapy for cancer. A patient interactive section and extended support for service development will ensure that anyone treated in the UK will have immediate access to the best knowledge in the country. This provides a solution for cost-effectiveness and future improvement of cancer care and is seen as a new model to support healthcare development and delivery. The charity ACORRN - Action Radiotherapy aims to support radiotherapy research and development and was launched in the House of Lords in July 2010.
Radiotherapy-induced hypopituitarism in nasopharyngeal carcinoma: the tip of an iceberg.
Ipekci, S H; Cakir, M; Kiyici, A; Koc, O; Artac, M
2015-07-01
Radiation-induced hypopituitarism is an important late complication of cranial radiotherapy in children and adults. The purpose of this cross-sectional study was to evaluate the effects of radiotherapy on pituitary function in adult nasopharyngeal carcinoma patients. Pituitary function was evaluated in 30 patients after cranial radiotherapy for nasopharyngeal carcinoma. Somatotroph and corticotroph axes were assessed by insulin tolerance test while gonadotroph and thyroid axes were evaluated by basal pituitary and end organ hormone levels at 10-133 months after radiotherapy. At least one hormonal disorder was observed in 28 (93%) patients after radiotherapy. 26 (87%) patients had one or more anterior pituitary hormone deficiencies. The rates of pituitary hormone deficiencies were 77% for growth hormone, followed by adrenocorticotropic hormone (73%), thyroid-stimulating hormone (27%) and gonadotropins (7%). Hyperprolactinemia was present in 13 (43%) patients. Radiation-induced hypopituitarism is more common than expected in patients with nasopharyngeal carcinoma. © Georg Thieme Verlag KG Stuttgart · New York.
DeCruze, B; Guthrie, D
1999-01-01
Poor prognosis (poorly differentiated and/or deep myometrial invasion) Stage I endometrial cancer can have a relapse rate as high as 50%. Traditionally, most clinical oncologists treat these patients with external beam radiotherapy after surgery but there is no evidence to show that this improves survival. The retrospective study looks at the results of not giving external beam radiotherapy in 25 consecutive patients and compares the results with a group of 13 consecutive patients who did have such treatment. The two groups were comparable with regard to age, degree of differentiation and degree of invasion. Survival was comparable in the two groups. There is no evidence of any obvious decrease in survival from withholding external beam radiotherapy, but this was not a prospective randomized controlled trial. This study illustrates that it is essential that the Medical Research Council ASTEC trial should be supported because this will determine the true place of external beam radiotherapy in such patients.
Caroline, Brammer; Sundus, Yahya; Dawn, Dawson; Carol, Glaister; Susan, Merrick
2016-12-01
The aim of this feasibility study is to define the resource effectiveness of cetuximab vs cisplatin given concomitantly with radiotherapy for squamous cell carcinoma within a National Health Service clinical oncology unit. 20 patients with Stage 3 or 4 head and neck squamous cell cancers were randomized to receive either cetuximab with radiotherapy (ERT) or cisplatin with radiotherapy concurrent with external beam radiotherapy 70 Gy in 35 fractions on a 1 : 1 basis over a 12-month duration. The study compared the resource utilization of ERT vs cisplatin with radiotherapy taking into account drug costs, clinical management and the costs of managing treatment-related toxicity from first fraction of radiotherapy to 6 months after the completion of therapy. Outcome measures were quality of life (recorded at the entry, end of radiotherapy, 6 weeks post treatment and 6 months post treatment), admissions to hospital, delays to radiotherapy, locoregional control and survival. Total drug costs including cost of nutritional supplements for patients treated with cetuximab were £7407.45 compared with £3959.07 for patients treated with cisplatin. Unscheduled admissions for toxicity management were significantly more common in the ERT arm. Healthcare personnel spent significantly more time delivering unscheduled outpatient care for patients receiving cisplatin than for those receiving cetuximab (p = 0.01). No significant difference in the quality of life was suggested at baseline, 6 weeks and 6 months. The mean time to removal of percutaneous gastrostomy (PEG) after completion of radiotherapy was 49.7 weeks in the cisplatin arm and 18.5 weeks in the cetuximab arm (p = 0.04). There was a statistically significant difference in patient-reported use of PEG between the cisplatin and cetuximab arms at 6 months following completion of treatment (p = 0.04). At 21 months, overall survival was 80% in the cisplatin arm vs 50% in the cetuximab (p = 0.332), with disease-free survival being 80% in the cisplatin arm vs 40% in the cetuximab (p = 0.097). Cetuximab is still more expensive in simple drug cost terms than cisplatin when delivered with radiotherapy taking into account costs of drugs for toxicity management and nutritional supplements but other resource implications such as inpatient admission, time spent delivering unscheduled care and cost of additional investigations to manage toxicity for patients treated with cisplatin significantly reduce differential. The study suggested significant differences in patient-reported PEG use at 6 months and in time to PEG removal in favour of the cetuximab arm. Advances in knowledge: There is paucity of randomized data on cost analysis for cisplatin vs cetuximab radiotherapy; this trial informs on the cost analysis between the two approaches.
Pont, Luis Parra; Marcelli, Stefano; Robustillo, Manuel; Song, Dajiang; Grandes, Daniel; Martin, Marcos; Iglesias, Israel; Aso, Jorge; Laloumet, Iñaki; Díaz, Antonio J
2017-10-01
The effects of postoperative radiotherapy on free flap-based breast reconstruction are still controversial. Poor outcomes, breast distortion, and fat necrosis have been traditionally documented. The aim of this study was to evaluate whether adjuvant radiotherapy affects the quality of life, satisfaction, and cosmetic result in patients undergoing immediate breast reconstruction with autologous free flap. Between January of 2013 and December of 2016, 230 patients underwent mastectomy with immediate free flap reconstruction at the authors' institution. Patients were divided into two groups depending on whether they received postmastectomy radiotherapy. Quality of life measured with the BREAST-Q questionnaire, self-reported aesthetic outcomes, and general satisfaction were assessed and compared. Fat necrosis of the flap and its severity were also analyzed as the main surgical outcomes. Mean follow-up time after reconstruction was 23 months (range, 6 to 48 months). No significant difference in quality of life or satisfaction scores were found between patients that underwent postmastectomy radiotherapy and patients who did not receive adjuvant radiotherapy. There were no significant differences in rates of fat necrosis between the groups (11.1 percent versus 13.76 percent; p = 0.75). Postmastectomy radiotherapy in patients undergoing immediate breast reconstruction with free flaps does not seem to affect quality of life, satisfaction with the outcome, or the cosmetic result as perceived by the patients. The potential need for postoperative radiotherapy should not hinder women from the benefits of autologous immediate breast reconstruction. Therapeutic, III.
Najafi, Shamsolmolok; Koujan, Soraiya Ebrahimpour; Manifar, Soheila; Kharazifard, Mohammad Javad; Kidi, Saba
2017-01-01
Objectives: About two-thirds of cancer patients undergo radiotherapy. Oral mucositis represents a major complication of radiotherapy, causing morbidity and mortality and decreasing the quality of life of patients. This study aimed to assess the preventive effect of Glycyrrhiza aqueous extract on oral mucositis in cancer patients under head and neck radiotherapy. Materials and Methods: In this double-blind clinical trial, 37 head and neck cancer patients were divided into intervention (n=19) group receiving Glycyrrhiza aqueous extract and control (n=18) group receiving placebo. Patients in the test group used Glycyrrhiza aqueous extract topically twice a day from the first day of starting radiotherapy until the end of the second week. Patients were examined in the first day of radiotherapy for any type of wound before treatment and those with oral ulcers before radiotherapy were excluded from the study. The grade of mucositis was determined using the classification by the World Health Organization. ANCOVA was performed to assess any difference between the two groups with regard to oral mucosal irritation and wound size after the intervention while controlling for the covariates such as sex and age. Results: Significant differences were found in the maximum grade of mucositis and oral mucosal irritation between the intervention and control groups (P<0.001). Conclusions: This study showed that aqueous extract of Glycyrrhiza can be effective for decreasing the severity of oral mucositis in head and neck cancer patients undergoing radiotherapy. PMID:29296112
Fitchett, Russell C; Aldus, Edward J; Fitchett, Lucy R; Cross, Jane
2018-06-08
This review aims to explore, appraise and synthesise the existing evidence of the meaning that head and neck cancer (HNC) patients assign to the experience of receiving curative radiotherapy. Qualitative evidence synthesis was undertaken using meta-ethnography. Published literature was identified using seven databases: AMED, ASSIA, CINAHL, EMBASE, MEDLINE, PubMed and PsycINFO. Databases were searched from January 2005 to April 2017. The strategy was supplemented by grey literature and citation searches. Out of 1403 titles, 57 abstracts and 35 full texts were screened. Ultimately, 8 studies were eligible for inclusion. The evidence base was moderate to strong in quality. Most of the studies showed that HNC patients undergoing radiotherapy have unmet needs. Four related concepts were identified: the disruption to life that the disease and radiotherapy treatment cause; patients' feelings of isolation; the need for patients to make sense of their situation; and the waiting and uncertainty that radiotherapy creates. The current literature suggests that both head and neck cancer and radiotherapy cause disruption in patients' lives. Radiotherapy causes many unpleasant side effects, and in this difficult treatment period, HNC patients feel isolated, uncertain and in need of coping strategies. Therapy radiographers are ideally placed to offer a supportive relationship. By having a deeper understanding of patients' lived experience, radiographers may form stronger relationships and more effectively help patients through their radiotherapy. This article is protected by copyright. All rights reserved.
Zhu, Guiqin; Dong, Yanbin; He, Xueming; Zhao, Ping; Yang, Aixing; Zhou, Rubing; Ma, Jianhua; Xie, Zhong; Song, Xue-Jun
2016-01-01
Radiotherapy is one of the major clinical approaches for treatment of bone cancer pain. Activation of cAMP-PKA signaling pathway plays important roles in bone cancer pain. Here, we examined the effects of radiotherapy on bone cancer pain and accompanying abnormal activation of cAMP-PKA signaling. Female Sprague-Dawley rats were used and received tumor cell implantation (TCI) in rat tibia (TCI cancer pain model). Some of the rats that previously received TCI treatment were treated with X-ray radiation (radiotherapy). Thermal hyperalgesia and mechanical allodynia were measured and used for evaluating level of pain caused by TCI treatment. PKA mRNA expression in dorsal root ganglion (DRG) was detected by RT-PCR. Concentrations of cAMP, IL-1β, and TNF-α as well as PKA activity in DRG and the spinal cord were measured by ELISA. The results showed that radiotherapy significantly suppressed TCI-induced thermal hyperalgesia and mechanical allodynia. The level of PKA mRNA in DRG, cAMP concentration and PKA activity in DRG and in the spinal cord, and concentrations of IL-1β and TNF-α in the spinal cord were significantly reduced by radiotherapy. In addition, radiotherapy also reduced TCI-induced bone loss. These findings suggest that radiotherapy may suppress bone cancer pain through inhibition of activation of cAMP-PKA signaling pathway in DRG and the spinal cord.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakraborty, Santam, E-mail: drsantam@gmail.com; Ghoshal, Sushmita; Patil, Vijay Maruti
2011-08-01
Purpose: To describe the results of conformal radiotherapy in advanced juvenile nasopharyngeal angiofibroma in a tertiary care institution. Methods and Materials: Retrospective chart review was conducted for 8 patients treated with conformal radiotherapy between 2006 and 2009. The median follow-up was 17 months. All patients had Stage IIIB disease with intracranial extension. Radiotherapy was considered as treatment because patients were deemed inoperable owing to extensive intracranial/intraorbital extension or proximity to optic nerve. All but 1 patient were treated with intensity-modulated radiotherapy using seven coplanar fields. Median (range) dose prescribed was 39.6 (30-46) Gy. Actuarial analysis of local control and descriptivemore » analysis of toxicity profile was conducted. Results: Despite the large and complex target volume (median planning target volume, 292 cm{sup 3}), intensity-modulated radiotherapy achieved conformal dose distributions (median van't Reit index, 0.66). Significant sparing of the surrounding organs at risk was obtained. No significant Grade 3/4 toxicities were experienced during or after treatment. Actual local control at 2 years was 87.5%. One patient died 1 month after radiotherapy secondary to massive epistaxis. The remaining 7 patients had progressive resolution of disease and were symptom-free at last follow-up. Persistent rhinitis was the only significant toxicity, seen in 1 patient. Conclusions: Conformal radiotherapy results in good local control with minimal acute and late side effects in juvenile nasopharyngeal angiofibromas, even in the presence of advanced disease.« less
Choi, Won Hoon
2016-01-01
Radiotherapy, which is one of three major cancer treatment methods in modern medicine, has continued to develop for a long period, more than a century. The development of radiotherapy means allowing the administration of higher doses to tumors to improve tumor control rates while minimizing the radiation doses absorbed by surrounding normal tissues through which radiation passes for administration to tumors, thereby reducing or removing the incidence of side effects. Such development of radiotherapy was accomplished by the development of clinical radiation oncology, the development of computers and machine engineering, the introduction of cutting-edge imaging technology, a deepened understanding of biological studies on the effects of radiation on human bodies, and the development of quality assurance (QA) programs in medical physics. The development of radiotherapy over the last two decades has been quite dazzling. Due to continuous improvements in cancer treatment, the average five-year survival rate of cancer patients has been close to 70%. The increases in cancer patients’ complete cure rates and survival periods are making patients’ quality of life during or after treatment a vitally important issue. Radiotherapy is implemented in approximately 1/3 to 2/3s of all cancer patients; and has improved the quality of life of cancer patients in the present age. Over the last century, as a noninvasive treatment, radiotherapy has unceasingly enhanced complete tumor cure rates and the side effects of radiotherapy have been gradually decreasing, resulting in a tremendous improvement in the quality of life of cancer patients. PMID:26908993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abouaf, Lucie; Girard, Nicolas; Claude Bernard University, Lyon
2012-03-01
Purpose: Radiotherapy has shown its efficacy in controlling optic nerve sheath meningiomas (ONSM) tumor growth while allowing visual acuity to improve or stabilize. However, radiation-induced toxicity may ultimately jeopardize the functional benefit. The purpose of this study was to identify predictive factors of poor visual outcome in patients receiving radiotherapy for ONSM. Methods and Materials: We conducted an extensive analysis of 10 patients with ONSM with regard to clinical, radiologic, and dosimetric aspects. All patients were treated with conformal radiotherapy and subsequently underwent biannual neuroophthalmologic and imaging assessments. Pretreatment and posttreatment values of visual acuity and visual field were comparedmore » with Wilcoxon's signed rank test. Results: Visual acuity values significantly improved after radiotherapy. After a median follow-up time of 51 months, 6 patients had improved visual acuity, 4 patients had improved visual field, 1 patient was in stable condition, and 1 patient had deteriorated visual acuity and visual field. Tumor control rate was 100% at magnetic resonance imaging assessment. Visual acuity deterioration after radiotherapy was related to radiation-induced retinopathy in 2 patients and radiation-induced mature cataract in 1 patient. Study of radiotherapy parameters showed that the mean eye dose was significantly higher in those 3 patients who had deteriorated vision. Conclusions: Our study confirms that radiotherapy is efficient in treating ONSM. Long-term visual outcome may be compromised by radiation-induced side effects. Mean eye dose has to be considered as a limiting constraint in treatment planning.« less
Bladder filling variation during conformal radiotherapy for rectal cancer
NASA Astrophysics Data System (ADS)
Sithamparam, S.; Ahmad, R.; Sabarudin, A.; Othman, Z.; Ismail, M.
2017-05-01
Conformal radiotherapy for rectal cancer is associated with small bowel toxicity mainly diarrhea. Treating patients with a full bladder is one of the practical solutions to reduce small bowel toxicity. Previous studies on prostate and cervix cancer patients revealed that maintaining consistent bladder volume throughout radiotherapy treatment is challenging. The aim of this study was to measure bladder volume variation throughout radiotherapy treatment. This study also measured the association between bladder volume changes and diarrhea. Twenty two rectal cancer patients were recruited prospectively. Patients were planned for treatment with full bladder following departmental bladder filling protocol and the planning bladder volume was measured during CT-simulation. During radiotherapy, the bladder volume was measured weekly using cone-beam computed tomography (CBCT) and compared to planning bladder volume. Incidence and severity of diarrhea were recorded during the weekly patient review. There was a negative time trend for bladder volume throughout five weeks treatment. The mean bladder volume decreased 18 % from 123 mL (SD 54 mL) during CT-simulation to 101 mL (SD 71 mL) on the 5th week of radiotherapy, but the decrease is not statistically significant. However, there was a large variation of bladder volume within each patient during treatment. This study showed an association between changes of bladder volume and diarrhea (P = 0.045). In conclusion bladder volume reduced throughout radiotherapy treatment for conformal radiotherapy for rectal cancer and there was a large variation of bladder volume within patients.
Small field electron beam dosimetry using MOSFET detector.
Amin, Md Nurul; Heaton, Robert; Norrlinger, Bern; Islam, Mohammad K
2010-10-04
The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small field electron beam dosimetry. Since modern radiotherapy departments are becoming filmless in favor of electronic imaging, an alternate and readily available clinical dosimeter needs to be explored. We have studied the performance of MOSFET as a relative dosimeter in small field electron beams. The reproducibility, linearity and sensitivity of a high-sensitivity microMOSFET were investigated for clinical electron beams. In addition, the percent depth doses, output factors and profiles have been measured in a water tank with MOSFET and compared with those measured by an ion chamber for a range of field sizes from 1 cm diameter to 10 cm × 10 cm for 6, 12, 16 and 20 MeV beams. Similar comparative measurements were also per-formed with MOSFET and films in solid water phantom. The MOSFET sensitivity was found to be practically constant over the range of field sizes investigated. The dose response was found to be linear and reproducible (within ± 1% for 100 cGy). An excellent agreement was observed among the central axis depth dose curves measured using MOSFET, film and ion chamber. The output factors measured with MOSFET for small fields agreed to within 3% with those measured by film dosimetry. Overall results indicate that MOSFET can be utilized to perform dosimetry for small field electron beam.
Severe skin reaction secondary to concomitant radiotherapy plus cetuximab
Berger, Bernhard; Belka, Claus
2008-01-01
The therapeutic use of monoclonal antibodies against the epidermal growth factor receptor (EGFR) is specifically associated with dermatologic reactions of variable severity. Recent evidence suggests superiority of the EGFR inhibitor (EGFRI) cetuximab plus radiotherapy compared to radiotherapy alone in patients with squamous cell carcinoma of the head and neck. Although not documented in a study population, several reports indicate a possible overlap between radiation dermatitis and the EGFRI-induced skin rash. We here present a case of severe skin reaction secondary to the addition of cetuximab to radiotherapy. PMID:18226196
Design and Shielding of Radiotherapy Treatment Facilities; IPEM Report 75, 2nd Edition
NASA Astrophysics Data System (ADS)
Horton, Patrick; Eaton, David
2017-07-01
Design and Shielding of Radiotherapy Treatment Facilities provides readers with a single point of reference for protection advice to the construction and modification of radiotherapy facilities. The book assembles a faculty of national and international experts on all modalities including megavoltage and kilovoltage photons, brachytherapy and high-energy particles, and on conventional and Monte Carlo shielding calculations. This book is a comprehensive reference for qualified experts and radiation-shielding designers in radiation physics and also useful to anyone involved in the design of radiotherapy facilities.
Adenocarcinoma of the ethmoid following radiotherapy for bilateral retinoblastoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowe, L.D.; Lane, R.; Snow, J.B. Jr.
1980-01-01
Adenocarcinoma of the ethmoid sinus is rare, representing only 4 to 8% of malignancies of the paranasal sinuses. An extraordinary case of papillary adenocarcinoma of the ethmoid sinus arising 30 years following high-dose radiotherapy for bilateral retinoblastoma is presented. Second fatal mesenchymal and epithelial primaries have been described in 8.5% of patients with bilateral retinoblastomas previously treated with radiotherapy; however, papillary adenocarcinoma arising within the paranasal sinuses has not been reported. Aggressive treatment including partial maxillectomy, radical pansinusectomy, radical neck dissection followed by regional radiotherapy and systemic chemotherapy failed to prevent the development of fatal hepatic metastases. The high incidencemore » of second fatal primary neoplasms in patients with bilateral retinoblastomas receiving radiation suggests an innate susceptibility that may add to the risk of radiotherapy.« less
MA, JIN-AN; LI, XUEZHEN; ZOU, WEN; ZHOU, YAN
2013-01-01
Radiotherapy is an effective treatment for nasopharyngeal carcinoma (NPC). A number of thyroid dysfunctions are induced by damage resulting from the relatively high doses of radiation administered to the thyroid and pituitary gland during radiotherapy. Hypothyroidism constitutes the most frequent type of thyroid dysfunction induced by NPC radiotherapy, while hyperthyroidism, particularly Grave’s disease, is extremely rare. The present study describes the case of a 40-year-old male who presented with Grave’s disease 2 years after receiving radiotherapy for the treatment of NPC. The patient exhibited swelling of the eyes, an increased appetite, decreased levels of thyroid-stimulating hormone, increased levels of triiodothyronine (T3) and thyroxine (T4) demonstrated by the examination of thyroid function and enlargement of the bilateral intraocular rectus revealed by CT scan. The patient’s symptoms were ameliorated following treatment with propylthiouracil and propranolol for 1 month, and the levels of T3 and T4 were restored to normal. The pathophysiological mechanism of radiotherapy-induced hyperthyroidism has yet to be elucidated. Hyperthyroidism is often neglected as several of its clinical manifestations are similar to other complications observed during and following cancer treatment. Therefore, it is necessary to monitor thyroid function following head and neck radiotherapy. PMID:23946792
Ma, Jin-An; Li, Xuezhen; Zou, Wen; Zhou, Yan
2013-07-01
Radiotherapy is an effective treatment for nasopharyngeal carcinoma (NPC). A number of thyroid dysfunctions are induced by damage resulting from the relatively high doses of radiation administered to the thyroid and pituitary gland during radiotherapy. Hypothyroidism constitutes the most frequent type of thyroid dysfunction induced by NPC radiotherapy, while hyperthyroidism, particularly Grave's disease, is extremely rare. The present study describes the case of a 40-year-old male who presented with Grave's disease 2 years after receiving radiotherapy for the treatment of NPC. The patient exhibited swelling of the eyes, an increased appetite, decreased levels of thyroid-stimulating hormone, increased levels of triiodothyronine (T3) and thyroxine (T4) demonstrated by the examination of thyroid function and enlargement of the bilateral intraocular rectus revealed by CT scan. The patient's symptoms were ameliorated following treatment with propylthiouracil and propranolol for 1 month, and the levels of T3 and T4 were restored to normal. The pathophysiological mechanism of radiotherapy-induced hyperthyroidism has yet to be elucidated. Hyperthyroidism is often neglected as several of its clinical manifestations are similar to other complications observed during and following cancer treatment. Therefore, it is necessary to monitor thyroid function following head and neck radiotherapy.
The desire to survive: the adaptation process of adult cancer patients undergoing radiotherapy.
Chao, Yu Huan; Wang, Shou-Yu; Hsu, Tsui Hua; Wang, Kai Wei K
2015-01-01
Radiotherapy is one of the primary treatment strategies for cancer. However, patients not only deal with the side-effects of radiotherapy, but they must also endure the psychological distress caused by cancer. This study explores how cancer patients adapt to the treatment process when receiving radiotherapy. This study used a grounded theory approach, and eight in-depth interviews were conducted with newly diagnosed cancer patients who received radiotherapy as a primary treatment. The core category that emerged from this study was "the desire to survive". The categories and subcategories that emerged from the data include facing unknown situations (e.g. searching for relevant information and decision-making considerations, and listening to healthcare professionals' suggestions), experiencing the pain of treatment (e.g. tolerating side-effects, tolerating inconvenience during the treatment, accepting support during the treatment, and adjusting lifestyles), and chances to extend life (e.g. accepting fate, determination to undergo the treatment, and adjusting negative emotions). The study results provide a better understanding of the experiences of cancer patients undergoing radiotherapy. Healthcare professionals should provide effective medical management for side-effects and psychological support to cancer patients during the journey of radiotherapy. © 2014 The Authors. Japan Journal of Nursing Science © 2014 Japan Academy of Nursing Science.
Zeguers, Maaike; de Haes, Hanneke C J M; Zandbelt, Linda C; Ter Hoeven, Claartje L; Franssen, Sanne J; Geijsen, Debbie D; Koning, Caro C E; Smets, Ellen M A
2012-01-01
To establish 1) further psychometric properties of the information preference for radiotherapy patients scale (IPRP); 2) what information new radiotherapy patients want to receive; 3) which patients have a lower information need. Eligible patients (n = 159; response rate 54%) of 15 radiation oncologists completed the IPRP and provided background characteristics before their first radiotherapy consultation. Exclusion criteria were: age <18 years, having undergone radiotherapy before, unable to read and write Dutch, cognitive problems or a brain tumor. Reliability (Cronbach's alpha 0.84-0.97) and concurrent validity (r from .39 to .57, p < 0.001) of the subscales of the IPRP were good. New radiotherapy patients want extensive information about their disease, treatment, procedures, side effects, and prognosis (mean scores between 4.1 and 4.4 on a scale from 1 to 5) but less information about psychosocial issues (mean = 3.4). Patients who are older and male, have lung or rectal cancer, more difficulty understanding and a higher trait anxiety level, need less information. The IPRP can reliably and validly address information needs of patients undergoing radiation treatment. Most new radiotherapy patients want much information. Yet, information giving should be tailored according to their background, understanding and anxiety. Copyright © 2012 Elsevier Inc. All rights reserved.
The significance of size change of soft tissue sarcoma during preoperative radiotherapy.
Miki, Y; Ngan, S; Clark, J C M; Akiyama, T; Choong, P F M
2010-07-01
To assess the significance of change in tumour size during preoperative radiotherapy in patients with soft tissue sarcoma (STS). A retrospective review of 91 cases with STS was performed. Inclusion criteria were localised extremity and truncal STS with measurable disease, older than 18 years, treated with preoperative radiotherapy and wide local excision, in the period between January 1966 and December 2005. Patients with head and neck STS, or who received neoadjuvant chemotherapy were excluded. A difference in excess of 10% of the greatest tumour diameter of the pre-radiotherapy and the post-radiotherapy MRI scans was considered as change in tumour size. Increase in tumour size was noted in 28 patients (31%) (Group 1). No change or decrease in size was observed in 63 patients (Group 2). There were no significance differences in local control or overall survival rates between the 2 groups. The estimated overall actuarial local recurrence free, event-free and overall survival rates were 90.5%, 64.4%, 62.9% in Group 1, and 85.7%, 60.8%, 68.9% in Group 2 respectively. Increase in tumour size during preoperative radiotherapy for soft tissue sarcoma does not seem to associate with inferior local tumour control or compromise survival. Lack of reduction in tumour size is not necessarily a sign of lack of response to preoperative radiotherapy.
Sahai, Puja; Kumar, Senthil
2017-08-01
This review aims to summarize the currently available evidence for the role of external radiotherapy and brachytherapy in the management of cholangiocarcinoma. High locoregional disease recurrence rates after surgical resection alone for both the extrahepatic cholangiocarcinoma (EHCC) and intrahepatic cholangiocarcinoma (IHCC) provide a rationale for using adjuvant radiotherapy with chemotherapy. We performed a literature search related to radiotherapy in cholangiocarcinoma published between 2000 and 2016. The role of radiation is discussed in the adjuvant, neoadjuvant, definitive and the palliative setting. Evidence from Phase II trials have demonstrated efficacy of adjuvant chemoradiation in combination with chemotherapy in EHCC. Locally advanced cholangiocarcinoma may be treated with neoadjuvant chemoradiotherapy. In the case of downsizing, assessment for resection may be considered. Brachytherapy offers dose escalation after external radiotherapy. Selected unresectable cases of cholangiocarcinoma may be considered for stereotactic body radiation therapy with neoadjuvant and/or concurrent chemotherapy. Liver transplantation is a treatment option in selected patients with EHCC and IHCC after neoadjuvant chemoradiation. Stenting in combination with palliative external radiotherapy and/or brachytherapy provides improved stent patency and survival. Newer advanced radiation techniques provide a scope for achieving better disease control with reduced morbidity. Effective multimodality treatment incorporating radiotherapy is the way forward for improving survival in patients with cholangiocarcinoma.
Villa, S; Bertoni, F; Bossi, A; Caraffini, B; Corbella, F; Di Lorenzo, I; Italia, C; Leoni, M; Nava, S; Sarti, E; Vavassori, V; Villa, E; Palazzi, M
1998-01-01
We report the results of a survey performed in 1994 by the AIRO-Lombardia Cooperative Group, on the clinical patterns of radiation treatment for prostatic carcinoma in Lombardy, Italy, involving all radiotherapy centers serving an overall local population of about 8,800,000 people. A questionnaire was sent to all 13 radiotherapy centers throughout Lombardy, asking for demographic and treatment details concerning the local population of patients with a localized (T1-4, N0-1, M0) carcinoma of the prostate treated with radiotherapy; 12 centers responded, making the basis for the present report. Analysis of collected data showed that in Lombardy: a) approximately 400 patients per year are irradiated for a localized carcinoma of the prostate, accounting for less than 30% of the total expected number of patients with this disease presentation; b) a complete staging (with PSA, transrectal ultrasonography, abdomino-pelvic CT or MRI scan and total-body bone scan) is performed in over 95% of patients before initiating radiotherapy; c) significant differences exist between radiotherapy centers as regards treatment planning and delivery. An urgent need exists for implementing procedures aimed at standardizing radiotherapy procedures within Lombardy.
Wong, Kee H; Panek, Rafal; Bhide, Shreerang A; Nutting, Christopher M; Harrington, Kevin J; Newbold, Katie L
2017-03-01
Head and neck cancer (HNC) is a challenging tumour site for radiotherapy delivery owing to its complex anatomy and proximity to organs at risk (OARs) such as the spinal cord and optic apparatus. Despite significant advances in radiotherapy planning techniques, radiation-induced morbidities remain substantial. Further improvement would require high-quality imaging and tailored radiotherapy based on intratreatment response. For these reasons, the use of MRI in radiotherapy planning for HNC is rapidly gaining popularity. MRI provides superior soft-tissue contrast in comparison with CT, allowing better definition of the tumour and OARs. The lack of additional radiation exposure is another attractive feature for intratreatment monitoring. In addition, advanced MRI techniques such as diffusion-weighted, dynamic contrast-enhanced and intrinsic susceptibility-weighted MRI techniques are capable of characterizing tumour biology further by providing quantitative functional parameters such as tissue cellularity, vascular permeability/perfusion and hypoxia. These functional parameters are known to have radiobiological relevance, which potentially could guide treatment adaptation based on their changes prior to or during radiotherapy. In this article, we first present an overview of the applications of anatomical MRI sequences in head and neck radiotherapy, followed by the potentials and limitations of functional MRI sequences in personalizing therapy.
Geng, Lidan; Wu, Rong; Hu, He; Zhao, Yu; Fan, Lingli; Zhao, Zhenhua; Liao, Dongbiao; Li, Musheng; Xiang, Miao; Ma, Ying; Du, Xiaobo
2018-05-01
Esophageal fistula is a serious and common complication of radiotherapy for esophageal cancer. Therefore, early diagnosis and treatment is necessary. Because of side effect of barium esophagography, it cannot be used to screening esophageal fistula during radiotherapy. Meglumine diatrizoate is an ionic contrast agent, its adverse reactions were rarely seen when it was used in the body cavity. The purpose of this trial is identified the sensitivity and specificity of oral meglumine diatrizoate in an esophagogram for screening esophageal fistula during radiotherapy. This trial was a prospective, multicenter, diagnostic clinical trial. A total of 105 patients with esophageal cancer will swallowed meglumine diatrizoate and underwent a radiographic examination weekly during radiotherapy, medical personnel observed the esophageal lesions to determine whether an esophageal fistula formed. If an esophageal fistula was observed, esophagofiberoscopy and/or computer tomography was used to further confirm the diagnosis. And the sensitivity and specificity of meglumine diatrizoate should be calculated for screening esophageal fistula during radiotherapy. To our knowledge, this study protocol is the first to identify the sensitivity and specificity of oral meglumine diatrizoate in an esophagogram for screening esophageal fistula during radiotherapy. If oral meglumine diatrizoate can be used to screening esophageal fistula, more patients will benefit from early detection and treatment.
Walker, Michael J.; Zhou, Cong; Backen, Alison; Pernemalm, Maria; Williamson, Andrew J.K.; Priest, Lynsey J.C.; Koh, Pek; Faivre-Finn, Corinne; Blackhall, Fiona H.; Dive, Caroline; Whetton, Anthony D.
2015-01-01
Lung cancer is the most frequent cause of cancer-related death world-wide. Radiotherapy alone or in conjunction with chemotherapy is the standard treatment for locally advanced non-small cell lung cancer (NSCLC). Currently there is no predictive marker with clinical utility to guide treatment decisions in NSCLC patients undergoing radiotherapy. Identification of such markers would allow treatment options to be considered for more effective therapy. To enable the identification of appropriate protein biomarkers, plasma samples were collected from patients with non-small cell lung cancer before and during radiotherapy for longitudinal comparison following a protocol that carries sufficient power for effective discovery proteomics. Plasma samples from patients pre- and during radiotherapy who had survived > 18 mo were compared to the same time points from patients who survived < 14 mo using an 8 channel isobaric tagging tandem mass spectrometry discovery proteomics platform. Over 650 proteins were detected and relatively quantified. Proteins which showed a change during radiotherapy were selected for validation using an orthogonal antibody-based approach. Two of these proteins were verified in a separate patient cohort: values of CRP and LRG1 combined gave a highly significant indication of extended survival post one week of radiotherapy treatment. PMID:26425690
Radiotherapy-induced hearing loss in patients with laryngeal and hypopharyngeal carcinomas.
Gudelj, Goran; Trotić, Robert; Herceg, Tonko; Parazajder, Domagoj; Vagić, Davor; Geber, Goran
2014-09-01
The purpose of this study was to investigate a hypothesized correlation of development of a sensorineural hearing loss and radiotherapy in patients with laryngeal and hypopharyngeal carcinoma. This prospective study included a total of 50 patients, which after strict exclusion critera (audiologic problems before RT primary tumors of the auditory system, spread of the primary tumor to any part of the auditory system) resulted in 23 analyzed patients, ranging between 50 and 76 years of age, with a mean age of 60. Audiometry measuring frequency-specific thresholds was performed in three time points: one month before radiotherapy, one and six months after radiotherapy. A significant statistical difference in hearing tresholds after radiotherapy was found in 6 out of 23 patients. An obvious tendency towards hearing loss without statistical significance at 250 and 4000 Hz was found for a whole tested population (p < or = 0.3 with Bonferroni correction). Observed tendency towards hearing loss after radiotherapy of laryngeal carcinoma was related to side of the tumor and less severe when chemotherapy was not added as adjuvant therapy. These results should help to decrease a rate of hearing loss by careful planing of ear protection, by using observed frequencies as relevant markers of hearing loss and by reconsidering adjuvant chemoterapy during radiotherapy of laryngeal carcinoma.
A systematic overview of radiation therapy effects in oesophageal cancer.
Ask, Anders; Albertsson, Maria; Järhult, Johannes; Cavallin-Ståhl, Eva
2003-01-01
A systematic review of radiation therapy trials in several tumour types was performed by The Swedish Council of Technology Assessment in Health Care (SBU). The procedures for evaluation of the scientific literature are described separately (Acta Oncol 2003; 42: 357-365). This synthesis of the literature on radiation therapy for oesophageal cancer is based on data from 42 randomized trials and 2 meta-analyses. A total of 44 scientific articles are included, involving 5 772 patients. The conclusions reached can be summarized as follows: There is fairly strong evidence that preoperative radiotherapy does not improve the survival in patients with potentially resectable oesophageal cancer. There is moderate evidence that preoperative chemo-radiotherapy has no beneficial impact on the survival of patients with potentially resectable oesophageal cancer. There is no scientific evidence that postoperative radiotherapy improves survival in patients with resectable oesophageal cancer. The documentation is, however, poor, consisting of only three randomized trials. There is fairly strong evidence that concomitant (but not sequential) chemo-radiotherapy gives significantly better survival rate than radiotherapy alone in inoperable oesophageal cancer. The results of the reported clinical trials are, however, conflicting, and no solid conclusion can be drawn. Hyperfractionated radiotherapy has been compared with conventionally fractionated radiotherapy in two randomized studies with conflicting results and no firm conclusion can be drawn.
Ohba, Hisateru; Narumi, Masakazu; Hosokawa, Yoichiro; Aoki, Masahiko
2010-01-01
The aim of this study was to measure and compare the geographical inequalities in radiotherapy health resources between the Hokkaido-Tohoku and Tokyo districts of Japan. The numbers of radiotherapy facilities, radiologists, and radiological technologists were used to represent radiotherapy health resources. The target areas were 11 prefectures in the Hokkaido-Tohoku and Tokyo districts. The Gini coefficient (GC) was used to measure inequalities in health resources in relation to the population and area of each secondary medical care zone. Correlation analysis was performed to clarify the relation between the GC and the all-cancer mortality rate per 100,000 people. The mean population and area GCs of Yamagata Prefecture were the smallest, whereas the mean population GC of Tokyo and the mean area GC of Hokkaido were the largest. The mean GCs of radiotherapy facilities and radiological technologists were higher in the Tokyo district than in the Hokkaido-Tohoku district. No significant correlation was found between GC and cancer mortality. Geographical inequalities in radiotherapy health resources tended to be larger in the Tokyo district than in the Hokkaido-Tohoku district. It is expected that the radiotherapy system will be substantially improved by the Basic Plan to Promote Cancer Control Programs.
Panek, Rafal; Bhide, Shreerang A; Nutting, Christopher M; Harrington, Kevin J; Newbold, Katie L
2017-01-01
Head and neck cancer (HNC) is a challenging tumour site for radiotherapy delivery owing to its complex anatomy and proximity to organs at risk (OARs) such as the spinal cord and optic apparatus. Despite significant advances in radiotherapy planning techniques, radiation-induced morbidities remain substantial. Further improvement would require high-quality imaging and tailored radiotherapy based on intratreatment response. For these reasons, the use of MRI in radiotherapy planning for HNC is rapidly gaining popularity. MRI provides superior soft-tissue contrast in comparison with CT, allowing better definition of the tumour and OARs. The lack of additional radiation exposure is another attractive feature for intratreatment monitoring. In addition, advanced MRI techniques such as diffusion-weighted, dynamic contrast-enhanced and intrinsic susceptibility-weighted MRI techniques are capable of characterizing tumour biology further by providing quantitative functional parameters such as tissue cellularity, vascular permeability/perfusion and hypoxia. These functional parameters are known to have radiobiological relevance, which potentially could guide treatment adaptation based on their changes prior to or during radiotherapy. In this article, we first present an overview of the applications of anatomical MRI sequences in head and neck radiotherapy, followed by the potentials and limitations of functional MRI sequences in personalizing therapy. PMID:28256151
Correa, Candace; Duane, Frances K.; Aznar, Marianne C.; Anderson, Stewart J.; Bergh, Jonas; Dodwell, David; Ewertz, Marianne; Gray, Richard; Jagsi, Reshma; Pierce, Lori; Pritchard, Kathleen I.; Swain, Sandra; Wang, Zhe; Wang, Yaochen; Whelan, Tim; Peto, Richard; McGale, Paul
2017-01-01
Purpose Radiotherapy reduces the absolute risk of breast cancer mortality by a few percentage points in suitable women but can cause a second cancer or heart disease decades later. We estimated the absolute long-term risks of modern breast cancer radiotherapy. Methods First, a systematic literature review was performed of lung and heart doses in breast cancer regimens published during 2010 to 2015. Second, individual patient data meta-analyses of 40,781 women randomly assigned to breast cancer radiotherapy versus no radiotherapy in 75 trials yielded rate ratios (RRs) for second primary cancers and cause-specific mortality and excess RRs (ERRs) per Gy for incident lung cancer and cardiac mortality. Smoking status was unavailable. Third, the lung or heart ERRs per Gy in the trials and the 2010 to 2015 doses were combined and applied to current smoker and nonsmoker lung cancer and cardiac mortality rates in population-based data. Results Average doses from 647 regimens published during 2010 to 2015 were 5.7 Gy for whole lung and 4.4 Gy for whole heart. The median year of irradiation was 2010 (interquartile range [IQR], 2008 to 2011). Meta-analyses yielded lung cancer incidence ≥ 10 years after radiotherapy RR of 2.10 (95% CI, 1.48 to 2.98; P < .001) on the basis of 134 cancers, indicating 0.11 (95% CI, 0.05 to 0.20) ERR per Gy whole-lung dose. For cardiac mortality, RR was 1.30 (95% CI, 1.15 to 1.46; P < .001) on the basis of 1,253 cardiac deaths. Detailed analyses indicated 0.04 (95% CI, 0.02 to 0.06) ERR per Gy whole-heart dose. Estimated absolute risks from modern radiotherapy were as follows: lung cancer, approximately 4% for long-term continuing smokers and 0.3% for nonsmokers; and cardiac mortality, approximately 1% for smokers and 0.3% for nonsmokers. Conclusion For long-term smokers, the absolute risks of modern radiotherapy may outweigh the benefits, yet for most nonsmokers (and ex-smokers), the benefits of radiotherapy far outweigh the risks. Hence, smoking can determine the net effect of radiotherapy on mortality, but smoking cessation substantially reduces radiotherapy risk. PMID:28319436
Sebag-Montefiore, David; Stephens, Richard J; Steele, Robert; Monson, John; Grieve, Robert; Khanna, Subhash; Quirke, Phil; Couture, Jean; de Metz, Catherine; Myint, Arthur Sun; Bessell, Eric; Griffiths, Gareth; Thompson, Lindsay C; Parmar, Mahesh
2009-01-01
Summary Background Preoperative or postoperative radiotherapy reduces the risk of local recurrence in patients with operable rectal cancer. However, improvements in surgery and histopathological assessment mean that the role of radiotherapy needs to be reassessed. We compared short-course preoperative radiotherapy versus initial surgery with selective postoperative chemoradiotherapy. Methods We undertook a randomised trial in 80 centres in four countries. 1350 patients with operable adenocarcinoma of the rectum were randomly assigned, by a minimisation procedure, to short-course preoperative radiotherapy (25 Gy in five fractions; n=674) or to initial surgery with selective postoperative chemoradiotherapy (45 Gy in 25 fractions with concurrent 5-fluorouracil) restricted to patients with involvement of the circumferential resection margin (n=676). The primary outcome measure was local recurrence. Analysis was by intention to treat. This study is registered, number ISRCTN 28785842. Findings At the time of analysis, which included all participants, 330 patients had died (157 preoperative radiotherapy group vs 173 selective postoperative chemoradiotherapy), and median follow-up of surviving patients was 4 years. 99 patients had developed local recurrence (27 preoperative radiotherapy vs 72 selective postoperative chemoradiotherapy). We noted a reduction of 61% in the relative risk of local recurrence for patients receiving preoperative radiotherapy (hazard ratio [HR] 0·39, 95% CI 0·27–0·58, p<0·0001), and an absolute difference at 3 years of 6·2% (95% CI 5·3–7·1) (4·4% preoperative radiotherapy vs 10·6% selective postoperative chemoradiotherapy). We recorded a relative improvement in disease-free survival of 24% for patients receiving preoperative radiotherapy (HR 0·76, 95% CI 0·62–0·94, p=0·013), and an absolute difference at 3 years of 6·0% (95% CI 5·3–6·8) (77·5% vs 71·5%). Overall survival did not differ between the groups (HR 0·91, 95% CI 0·73–1·13, p=0·40). Interpretation Taken with results from other randomised trials, our findings provide convincing and consistent evidence that short-course preoperative radiotherapy is an effective treatment for patients with operable rectal cancer. Funding Medical Research Council (UK) and the National Cancer Institute of Canada. PMID:19269519
Taylor, Carolyn; Correa, Candace; Duane, Frances K; Aznar, Marianne C; Anderson, Stewart J; Bergh, Jonas; Dodwell, David; Ewertz, Marianne; Gray, Richard; Jagsi, Reshma; Pierce, Lori; Pritchard, Kathleen I; Swain, Sandra; Wang, Zhe; Wang, Yaochen; Whelan, Tim; Peto, Richard; McGale, Paul
2017-05-20
Purpose Radiotherapy reduces the absolute risk of breast cancer mortality by a few percentage points in suitable women but can cause a second cancer or heart disease decades later. We estimated the absolute long-term risks of modern breast cancer radiotherapy. Methods First, a systematic literature review was performed of lung and heart doses in breast cancer regimens published during 2010 to 2015. Second, individual patient data meta-analyses of 40,781 women randomly assigned to breast cancer radiotherapy versus no radiotherapy in 75 trials yielded rate ratios (RRs) for second primary cancers and cause-specific mortality and excess RRs (ERRs) per Gy for incident lung cancer and cardiac mortality. Smoking status was unavailable. Third, the lung or heart ERRs per Gy in the trials and the 2010 to 2015 doses were combined and applied to current smoker and nonsmoker lung cancer and cardiac mortality rates in population-based data. Results Average doses from 647 regimens published during 2010 to 2015 were 5.7 Gy for whole lung and 4.4 Gy for whole heart. The median year of irradiation was 2010 (interquartile range [IQR], 2008 to 2011). Meta-analyses yielded lung cancer incidence ≥ 10 years after radiotherapy RR of 2.10 (95% CI, 1.48 to 2.98; P < .001) on the basis of 134 cancers, indicating 0.11 (95% CI, 0.05 to 0.20) ERR per Gy whole-lung dose. For cardiac mortality, RR was 1.30 (95% CI, 1.15 to 1.46; P < .001) on the basis of 1,253 cardiac deaths. Detailed analyses indicated 0.04 (95% CI, 0.02 to 0.06) ERR per Gy whole-heart dose. Estimated absolute risks from modern radiotherapy were as follows: lung cancer, approximately 4% for long-term continuing smokers and 0.3% for nonsmokers; and cardiac mortality, approximately 1% for smokers and 0.3% for nonsmokers. Conclusion For long-term smokers, the absolute risks of modern radiotherapy may outweigh the benefits, yet for most nonsmokers (and ex-smokers), the benefits of radiotherapy far outweigh the risks. Hence, smoking can determine the net effect of radiotherapy on mortality, but smoking cessation substantially reduces radiotherapy risk.
Liu, Yue-E; Lin, Qiang; Meng, Fan-Jie; Chen, Xue-Ji; Ren, Xiao-Cang; Cao, Bin; Wang, Na; Zong, Jie; Peng, Yu; Ku, Ya-Jun; Chen, Yan
2013-08-11
Increasing the radiotherapy dose can result in improved local control for non-small-cell lung cancer (NSCLC) and can thereby improve survival. Accelerated hypofractionated radiotherapy can expose tumors to a high dose of radiation in a short period of time, but the optimal treatment regimen remains unclear. The purpose of this study was to evaluate the feasibility of utilizing high-dose accelerated hypofractionated three-dimensional conformal radiotherapy (at 3 Gy/fraction) with concurrent vinorelbine (NVB) and carboplatin (CBP) chemotherapy for the treatment of local advanced NSCLC. Untreated patients with unresectable stage IIIA/IIIB NSCLC or patients with a recurrence of NSCLC received accelerated hypofractionated three-dimensional conformal radiotherapy. The total dose was greater than or equal to 60 Gy. The accelerated hypofractionated radiotherapy was conducted once daily at 3 Gy/fraction with 5 fractions per week, and the radiotherapy was completed in 5 weeks. In addition to radiotherapy, the patients also received at least 1 cycle of a concurrent two-drug chemotherapy regimen of NVB and CBP. A total of 26 patients (19 previously untreated cases and 7 cases of recurrent disease) received 60Gy-75Gy radiotherapy with concurrent chemotherapy. All of the patients underwent evaluations for toxicity and preliminary therapeutic efficacy. There were no treatment-related deaths within the entire patient group. The major acute adverse reactions were radiation esophagitis (88.5%) and radiation pneumonitis (42.3%). The percentages of grade III acute radiation esophagitis and grade III radiation pneumonitis were 15.4% and 7.7%, respectively. Hematological toxicities were common and did not significantly affect the implementation of chemoradiotherapy after supportive treatment. Two patients received high dose of 75 Gy had grade III late esophageal toxicity, and none had grade IV and above. Grade III and above late lung toxicity did not occur. High-dose accelerated hypofractionated three-dimensional conformal radiotherapy with a dose of 60 Gy or greater with concurrent NVB and CBP chemotherapy might be feasible. However esophagus toxicity needs special attention. A phase I trial is recommended to obtain the maximum tolerated radiation dose of accelerated hypofractionated radiotherapy with concurrent chemotherapy.
2013-01-01
Background Increasing the radiotherapy dose can result in improved local control for non-small-cell lung cancer (NSCLC) and can thereby improve survival. Accelerated hypofractionated radiotherapy can expose tumors to a high dose of radiation in a short period of time, but the optimal treatment regimen remains unclear. The purpose of this study was to evaluate the feasibility of utilizing high-dose accelerated hypofractionated three-dimensional conformal radiotherapy (at 3 Gy/fraction) with concurrent vinorelbine (NVB) and carboplatin (CBP) chemotherapy for the treatment of local advanced NSCLC. Methods Untreated patients with unresectable stage IIIA/IIIB NSCLC or patients with a recurrence of NSCLC received accelerated hypofractionated three-dimensional conformal radiotherapy. The total dose was greater than or equal to 60 Gy. The accelerated hypofractionated radiotherapy was conducted once daily at 3 Gy/fraction with 5 fractions per week, and the radiotherapy was completed in 5 weeks. In addition to radiotherapy, the patients also received at least 1 cycle of a concurrent two-drug chemotherapy regimen of NVB and CBP. Results A total of 26 patients (19 previously untreated cases and 7 cases of recurrent disease) received 60Gy-75Gy radiotherapy with concurrent chemotherapy. All of the patients underwent evaluations for toxicity and preliminary therapeutic efficacy. There were no treatment-related deaths within the entire patient group. The major acute adverse reactions were radiation esophagitis (88.5%) and radiation pneumonitis (42.3%). The percentages of grade III acute radiation esophagitis and grade III radiation pneumonitis were 15.4% and 7.7%, respectively. Hematological toxicities were common and did not significantly affect the implementation of chemoradiotherapy after supportive treatment. Two patients received high dose of 75 Gy had grade III late esophageal toxicity, and none had grade IV and above. Grade III and above late lung toxicity did not occur. Conclusion High-dose accelerated hypofractionated three-dimensional conformal radiotherapy with a dose of 60 Gy or greater with concurrent NVB and CBP chemotherapy might be feasible. However esophagus toxicity needs special attention. A phase I trial is recommended to obtain the maximum tolerated radiation dose of accelerated hypofractionated radiotherapy with concurrent chemotherapy. PMID:23937855
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mehta, Minesh P.; Tsao, May N.; Whelan, Timothy J.
2005-09-01
Purpose: To systematically review the evidence for the use of stereotactic radiosurgery in adult patients with brain metastases. Methods: Key clinical questions to be addressed in this evidence-based review were identified. Outcomes considered were overall survival, quality of life or symptom control, brain tumor control or response and toxicity. MEDLINE (1990-2004 June Week 2), CANCERLIT (1990-2003), CINAHL (1990-2004 June Week 2), EMBASE (1990-2004 Week 25), and the Cochrane library (2004 issue 2) databases were searched using OVID. In addition, the Physician Data Query clinical trials database, the proceedings of the American Society of Clinical Oncology (ASCO) (1997-2004), ASTRO (1997-2004), andmore » the European Society of Therapeutic Radiology and Oncology (ESTRO) (1997-2003) were searched. Data from the literature search were reviewed and tabulated. This process included an assessment of the level of evidence. Results: For patients with newly diagnosed brain metastases, managed with whole-brain radiotherapy alone vs. whole-brain radiotherapy and radiosurgery boost, there were three randomized controlled trials, zero prospective studies, and seven retrospective series (which satisfied inclusion criteria). For patients with up to three (<4 cm) newly diagnosed brain metastases (and in one study up to four brain metastases), radiosurgery boost with whole-brain radiotherapy significantly improves local brain control rates as compared with whole-brain radiotherapy alone (Level I-III evidence). In one large randomized trial, survival benefit with whole-brain radiotherapy was observed in patients with single brain metastasis. In this trial, an overall increased ability to taper down on steroid dose and an improvement in Karnofsky performance status was seen in patients who were treated with radiosurgery boost as compared with patients treated with whole-brain radiotherapy alone. However, Level I evidence regarding overall quality of life outcomes using a validated instrument has not been reported. All randomized trials showed improved local control with the addition of radiosurgery to whole-brain radiotherapy. For patients with multiple brain metastases, there is no overall survival benefit with the use of radiosurgery boost to whole-brain radiotherapy (Level I-III evidence). Radiosurgery boost is associated with a small risk of early or late toxicity. In patients treated with radiosurgery alone (withholding whole-brain radiotherapy) as initial treatment, there were 2 randomized trials, 2 prospective cohort studies, and 16 retrospective series. There is Level I to Level III evidence that the use of radiosurgery alone does not alter survival as compared to the use of whole-brain radiotherapy. However, there is Level I to Level III evidence that omission of whole-brain radiotherapy results in poorer intracranial disease control, both local and distant (defined as remaining brain, outside the radiosurgery field). Quality of life outcomes have not been adequately reported. Radiosurgery is associated with a small risk of early or late toxicity. Radiosurgery as salvage for patients with brain metastases was reported in zero randomized trials, one prospective study, and seven retrospective series. Conclusions: Based on Level I-III evidence, for selected patients with small (up to 4 cm) brain metastases (up to three in number and four in one randomized trial), the addition of radiosurgery boost to whole-brain radiotherapy improves brain control as compared with whole-brain radiotherapy alone. In patients with a single brain metastasis, radiosurgery boost with whole-brain radiotherapy improves survival. There is a small risk of toxicity associated with radiosurgery boost as compared with whole-brain radiotherapy alone. In selected patients treated with radiosurgery alone for newly diagnosed brain metastases, overall survival is not altered. However, local and distant brain control is significantly poorer with omission of upfront whole-brain radiotherapy (Level I-III evidence). Whether neurocognition or quality of life outcomes are different between initial radiosurgery alone vs. whole-brain radiotherapy (with or without radiosurgery boost) is unknown, because this has not been adequately tested. There was no statistically significant difference in overall toxicity between those treated with radiosurgery alone vs. whole-brain radiotherapy and radiosurgery boost based on an interim report from one randomized study. There is insufficient evidence as to the clinical benefit/risks radiosurgery used in the setting of recurrent or progressive brain metastases, although radiographic responses are well-documented.« less
Zhong, Q Z; Wang, Z; Tang, Y; Rong, Q L; Wang, S L; Jin, J; Wang, W H; Liu, Y P; Song, Y W; Fang, H; Chen, B; Qi, S N; Li, N; Tang, Y; Zhang, J H; Li, Y X
2017-04-23
Objective: To evaluate the prognostic value of sequencing of adjuvant radiotherapy and chemotherapy following breast-conserving surgery for patients with breast cancer. Methods: A total of 1 154 patients withT1-2N0-3M0 breast cancer retrospectively reviewed. All patients received sequential radiotherapy and chemotherapy following breast-conserving surgery. Among them, 603 patients received radiotherapy first and 551 patients received chemotherapy first. Log-rank tests were used to determine significance of disease-free survival (DFS) and overall survival (OS) rates in the Kaplan-Meier curve. Results: The 5-year DFS and OS rates for all patients were 93.0% and 97.8%. The 5-year OS rate was 98.6% in the radiotherapy first group and 96.4% in the chemotherapy first group ( P =0.191), and the corresponding DFS rate was 92.7% and 93.2% ( P =0.430), respectively. Among the patients with Luminal A subtype, the 5-year OS rate was 99.6% in the radiotherapy first group and 97.8% in the chemotherapy first group ( P =0.789). Among the patients with Luminal B subtype, the 5-year OS rate was 94.2% and 96.0%, respectively ( P =0.680). Among the patients with triple negative breast cancer, the 5-year OS rate was 100% and 90.9%, respectively, with statistically significant differences ( P =0.019). Among the patients with HER-2 positive breast cancer, The 5-year DFS rate was 80.1% and 100%, respectively ( P =0.045). Conclusions: The OS and DFS rates in the chemotherapy first group are not significantly different from those of radiotherapy first group after breast-conserving surgery. Patients with HER-2 positive breast cancer in chemotherapy first group have a much higher DFS rate than that of radiotherapy first group, whereas patients with triple negative breast cancer in radiotherapy first group have a better OS rate than that of chemotherapy first group. Further research is warranted to investigate the benefit of different molecular types in different sequencing of radiotherapy and chemotherapy after breast-conserving surgery.
Radiotherapy demand and activity in England 2006-2020.
Round, C E; Williams, M V; Mee, T; Kirkby, N F; Cooper, T; Hoskin, P; Jena, R
2013-09-01
This paper compares the predictions of radiotherapy demand for England from the Malthus model with those from the earlier National Radiotherapy Advisory Group (NRAG) model, from the international literature and also with observed radiotherapy usage in England as a whole as recorded in the English radiotherapy dataset (RTDS). We reviewed the evidence base for radiotherapy for each type and stage of cancer using national and international guidelines, meta-analyses, systematic reviews and key clinical trials. Twenty-two decision trees were constructed and radiotherapy demand was calculated using English cancer incidence data for 2007, 2008 and 2009, accurate to the Primary Care Trust (PCT) level (population 91,500-1,282,384). The stage at presentation was obtained from English cancer registry data. In predictive mode, the model can take account of changes in cancer incidence as the population grows and ages. The Malthus model indicates reduced indications for radiotherapy, principally for lung cancer and rarer tumours. Our estimate of the proportion of patients who should receive radiotherapy at some stage of their illness is 40.6%. This is lower than previous estimates of about 50%. Nevertheless, the overall estimate of demand in terms of attendances is similar for the NRAG and Malthus models. The latter models that 48,827 attendances should have been delivered per million population in 2011. National data from RTDS show 32,071 attendances per million in 2011. A 50% increase in activity would be required to match estimated demand. This underprovision extends across all cancers and represents reduced access and the use of dose fractionation at odds with international norms of evidence-based practice. By 2016, demand is predicted to grow to about 55,206 attendances per million and by 2020 to 60,057. Services have increased their activity by 14% between 2006 and 2011, but estimated demand has increased by 11%. Access remains low and English radiotherapy dose fractionation still does not comply with international evidence-based practice. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishii, M.A.; Kimura, M.; Inokuti, M.
1990-12-01
A comparative study of electron degradation spectra and yields for various species in gaseous and solid H{sub 2}O is carred out by using the rigorous Spencer-Fano theory and the continuous-slowing-down approximation (CSDA). As input we use cross-section data given by Hayashi (in {ital Atomic} {ital and} {ital Molecular} {ital Data} {ital for} {ital Radiotherapy}, Proceedings of an IAEA Advisory Group Meeting, Vienna, June 1988, Report No. IAEA-TECDOC-506 (International Atomic Energy Agency, Vienna, 1989), p. 193) for the gas and by Michaud and Sanche (Phys. Rev. 36, 4672 (1987)) for the solid. Vibrational excitation is the dominant mechanism of the slowingmore » down of the electron in both gas and solid phases at intermediate energies of 8--2 eV. Rotational excitation for the gas and phonon excitation for the solid, which share the same origin of dynamics, are the second important mechanism. The general trends of the electron degradation spectra are similar in the two phases. However, details of the spectra differ notably from one another. Because the energy dependence of some of the cross sections is complex, the CSDA fails to reproduce even a local average of the Spencer-Fano degradation spectrum, and gives yields of various products appreciably different from those evaluated from the Spencer-Fano degradation spectrum.« less