Agoro, Oscar O; Kibira, Sarah W; Freeman, Jenny V; Fraser, Hamish S F
2018-06-01
Electronic pharmacovigilance reporting systems are being implemented in many developing countries in an effort to improve reporting rates. This study sought to establish the factors that acted as barriers to the success of an electronic pharmacovigilance reporting system in Kenya 3 years after its implementation. Factors that could act as barriers to using electronic reporting systems were identified in a review of literature and then used to develop a survey questionnaire that was administered to pharmacists working in government hospitals in 6 counties in Kenya. The survey was completed by 103 out of the 115 targeted pharmacists (89.5%) and included free-text comments. The key factors identified as barriers were: unavailable, unreliable, or expensive Internet access; challenges associated with a hybrid system of paper and electronic reporting tools; and system usability issues. Coordination challenges at the national pharmacovigilance center and changes in the structure of health management in the country also had an impact on the success of the electronic reporting system. Different personal, organizational, infrastructural, and reporting system factors affect the success of electronic reporting systems in different ways, depending on the context. Context-specific formative evaluations are useful in establishing the performance of electronic reporting systems to identify problems and ensure that they achieve the desired objectives. While several factors hindered the optimal use of the electronic pharmacovigilance reporting system in Kenya, all were considered modifiable. Effort should be directed toward tackling the identified issues in order to facilitate use and improve pharmacovigilance reporting rates.
NASA Technical Reports Server (NTRS)
Tuey, Richard C.; Lane, Robert; Hart, Susan V.
1995-01-01
The NASA Scientific and Technical Information Office was assigned the responsibility to continue with the expansion of the NASAwide networked electronic duplicating effort by including the Goddard Space Flight Center (GSFC) as an additional node to the existing configuration of networked electronic duplicating systems within NASA. The subject of this report is the evaluation of a networked electronic duplicating system which meets the duplicating requirements and expands electronic publishing capabilities without increasing current operating costs. This report continues the evaluation reported in 'NASA Electronic Publishing System - Electronic Printing and Duplicating Evaluation Report' (NASA TM-106242) and 'NASA Electronic Publishing System - Stage 1 Evaluation Report' (NASA TM-106510). This report differs from the previous reports through the inclusion of an external networked desktop editing, archival, and publishing functionality which did not exist with the previous networked electronic duplicating system. Additionally, a two-phase approach to the evaluation was undertaken; the first was a paper study justifying a 90-day, on-site evaluation, and the second phase was to validate, during the 90-day evaluation, the cost benefits and productivity increases that could be achieved in an operational mode. A benchmark of the functionality of the networked electronic publishing system and external networked desktop editing, archival, and publishing system was performed under a simulated daily production environment. This report can be used to guide others in determining the most cost effective duplicating/publishing alternative through the use of cost/benefit analysis and return on investment techniques. A treatise on the use of these techniques can be found by referring to 'NASA Electronic Publishing System -Cost/Benefit Methodology' (NASA TM-106662).
Toprani, Amita; Madsen, Ann; Das, Tara; Gambatese, Melissa; Greene, Carolyn; Begier, Elizabeth
2014-01-01
New York City (NYC) mandates reporting of all abortion procedures. These reports enable tracking of abortion incidence and underpin programs, policy, and research. Since January 2011, the majority of abortion facilities must report electronically. We conducted an evaluation of NYC's abortion reporting system and its transition to electronic reporting. We summarize the evaluation methodology and results and draw lessons relevant to other vital statistics and public health reporting systems. The evaluation followed Centers for Disease Control and Prevention guidelines for evaluating public health surveillance systems. We interviewed key stakeholders and conducted a data provider survey. In addition, we compared the system's abortion counts with external estimates and calculated the proportion of missing and invalid values for each variable on the report form. Finally, we assessed the process for changing the report form and estimated system costs. NYC Health Department's Bureau of Vital Statistics. Usefulness, simplicity, flexibility, data quality, acceptability, sensitivity, timeliness, and stability of the abortion reporting system. Ninety-five percent of abortion data providers considered abortion reporting important; 52% requested training regarding the report form. Thirty percent reported problems with electronic biometric fingerprint certification, and 18% reported problems with the electronic system's stability. Estimated system sensitivity was 88%. Of 17 variables, education and ancestry had more than 5% missing values in 2010. Changing the electronic reporting module was costly and time-consuming. System operating costs were estimated at $80 136 to $89 057 annually. The NYC abortion reporting system is sensitive and provides high-quality data, but opportunities for improvement include facilitating biometric certification, increasing electronic platform stability, and conducting ongoing outreach and training for data providers. This evaluation will help data users determine the degree of confidence that should be placed on abortion data. In addition, the evaluation results are applicable to other vital statistics reporting and surveillance systems.
This procedure describes how to apply for and obtain approval of electronic reporting systems used to receive electronic documents in lieu of paper where the report is made pursuant to requirements or authority codified in CFR 40.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-18
... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0021] Proposed Information Collection (VA Loan Electronic Reporting Interface (VALERI) System) Activity: Comment Request AGENCY: Veterans... techniques or the use of other forms of information technology. Title: VA Loan Electronic Reporting Interface...
Stiltner, G.J.
1990-01-01
In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25% less than costs of printing the reports prepared by conventional methods. Because the largest report workload in the offices conducting water resources investigations is preparation of Water-Resources Investigations Reports, Open-File Reports, and annual State Data Reports, the pilot studies only involved these projects. (USGS)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-04
... Electronics Manufacturing and the Petroleum and Natural Gas Systems Categories of the Greenhouse Gas Reporting...: Technical Revisions to the Electronics Manufacturing and the Petroleum and Natural Gas Systems Categories of... to the Electronics Manufacturing and the Petroleum and Natural Gas Systems Categories of the...
Ahmadi, Maryam; Ghazisaeidi, Marjan; Bashiri, Azadeh
2015-03-18
In order to better designing of electronic health record system in Iran, integration of health information systems based on a common language must be done to interpret and exchange this information with this system is required. This study provides a conceptual model of radiology reporting system using unified modeling language. The proposed model can solve the problem of integration this information system with the electronic health record system. By using this model and design its service based, easily connect to electronic health record in Iran and facilitate transfer radiology report data. This is a cross-sectional study that was conducted in 2013. The study population was 22 experts that working at the Imaging Center in Imam Khomeini Hospital in Tehran and the sample was accorded with the community. Research tool was a questionnaire that prepared by the researcher to determine the information requirements. Content validity and test-retest method was used to measure validity and reliability of questioner respectively. Data analyzed with average index, using SPSS. Also Visual Paradigm software was used to design a conceptual model. Based on the requirements assessment of experts and related texts, administrative, demographic and clinical data and radiological examination results and if the anesthesia procedure performed, anesthesia data suggested as minimum data set for radiology report and based it class diagram designed. Also by identifying radiology reporting system process, use case was drawn. According to the application of radiology reports in electronic health record system for diagnosing and managing of clinical problem of the patient, with providing the conceptual Model for radiology reporting system; in order to systematically design it, the problem of data sharing between these systems and electronic health records system would eliminate.
Matsumura, Yasushi; Hattori, Atsushi; Manabe, Shiro; Takahashi, Daiyo; Yamamoto, Yuichiro; Murata, Taizo; Nakagawa, Akito; Mihara, Naoki; Takeda, Toshihiro
2017-01-01
To improve the efficiency of clinical research, we developed a system to integrate electronic medical records (EMRs) and the electronic data capture system (EDC). EDC is divided into case report form (CRF) reporter and CDMS with CRF receiver with data communication using the operational data model (ODM). The CRF reporter is incorporated into the EMR to share data witth the EMR. In the data transcription type, doctors enter data using a progress note template, which are transmitted to the reporter template. It then generates the ODM. In the direct record type, reporter templates open from the progress note and generate narrative text to make record in the progress note. The configuration files for a study are delivered from the contents server to minimize the setup. This system has been used for 15 clinical studies including 3 clinical trials. This system can save labor and financial costs in clinical research.
Cross-Media Electronic Reporting Rule
Cross-Media Electronic Reporting Regulation (CROMERR) sets performance-based, technology-neutral standards for systems that states, tribes, and local governments use to receive electronic reports from facilities they regulate under EPA-authorized programs.
78 FR 35936 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-14
... Reporting System (PQRS) and Electronic Prescribing (eRx) Incentive Program Under the Paperwork Reduction Act... Collection: Evaluation of the Physician Quality Reporting System (PQRS) and Electronic Prescribing (eRx) Incentive Program; Use: The Physician Quality Reporting System (PQRS) was first implemented in 2007 as an...
An examination of safety reports involving electronic flight bags and portable electronic devices
DOT National Transportation Integrated Search
2014-06-01
The purpose of this research was to develop a better understanding of safety considerations with the use of Electronic Flight Bags (EFBs) and Portable Electronic Devices (PEDs) by examining safety reports from Aviation Safety Reporting System (ASRS),...
Lawpoolsri, Saranath; Khamsiriwatchara, Amnat; Liulark, Wongwat; Taweeseneepitch, Komchaluch; Sangvichean, Aumnuyphan; Thongprarong, Wiraporn; Kaewkungwal, Jaranit; Singhasivanon, Pratap
2014-05-12
School absenteeism is a common source of data used in syndromic surveillance, which can eventually be used for early outbreak detection. However, the absenteeism reporting system in most schools, especially in developing countries, relies on a paper-based method that limits its use for disease surveillance or outbreak detection. The objective of this study was to develop an electronic real-time reporting system on school absenteeism for syndromic surveillance. An electronic (Web-based) school absenteeism reporting system was developed to embed it within the normal routine process of absenteeism reporting. This electronic system allowed teachers to update students' attendance status via mobile tablets. The data from all classes and schools were then automatically sent to a centralized database for further analysis and presentation, and for monitoring temporal and spatial patterns of absent students. In addition, the system also had a disease investigation module, which provided a link between absenteeism data from schools and local health centers, to investigate causes of fever among sick students. The electronic school absenteeism reporting system was implemented in 7 primary schools in Bangkok, Thailand, with total participation of approximately 5000 students. During May-October 2012 (first semester), the percentage of absentees varied between 1% and 10%. The peak of school absenteeism (sick leave) was observed between July and September 2012, which coincided with the peak of dengue cases in children aged 6-12 years being reported to the disease surveillance system. The timeliness of a reporting system is a critical function in any surveillance system. Web-based application and mobile technology can potentially enhance the use of school absenteeism data for syndromic surveillance and outbreak detection. This study presents the factors that determine the implementation success of this reporting system.
Visual Support System for Report Distinctiveness Evaluation
NASA Astrophysics Data System (ADS)
Sunayama, Wataru; Kawaguchi, Toshiaki
In recent years, as the Internet has grown, electronic reports have come to be used in educational organizations such as universities. Though reports written by hand must be evaluated by hand except for stereotype descriptions or numerical answers, electronic reports can be rated by computer. There are two major criteria in rating reports, correctness and distinctiveness. Correctness is rated by absolute criteria and distinctiveness is rated by relative criteria. Relative evaluation is difficult because raters should memorize all contents of submitted reports to provide objective rates. In addition, electronic data are easily copied or exchanged by students. This paper presents a report evaluation support system with which raters can compare each report and give objective rates for distinctiveness. This system evaluates each report by objective similarity criteria and visualizes them in a two-dimensional interface as the calculated distinctiveness order. Experimental results show the system is valid and effective for estimating associations between reports.
Electronic Systems for Spacecraft Vehicles: Required EDA Tools
NASA Technical Reports Server (NTRS)
Bachnak, Rafic
1999-01-01
The continuous increase in complexity of electronic systems is making the design and manufacturing of such systems more challenging than ever before. As a result, designers are finding it impossible to design efficient systems without the use of sophisticated Electronic Design Automation (EDA) tools. These tools offer integrated simulation of the electrical, mechanical, and manufacturing functions and lead to a correct by design methodology. This report identifies the EDA tools that would be needed to design, analyze, simulate, and evaluate electronic systems for spacecraft vehicles. In addition, the report presents recommendations to enhance the current JSC electronic design capabilities. This includes cost information and a discussion as to the impact, both positive and negative, of implementing the recommendations.
75 FR 8296 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-24
... Service Title: Electronic Animal Disease Reporting System. OMB Control Number: 0583-0139. Summary of..., establishments that slaughter meat, poultry, exotic animals, and rabbits are required to maintain certain records...'s electronic Animal Disease Reporting System (eADRS), establishments report (by shift) slaughter...
A strategy for electronic dissemination of NASA Langley technical publications
NASA Technical Reports Server (NTRS)
Roper, Donna G.; Mccaskill, Mary K.; Holland, Scott D.; Walsh, Joanne L.; Nelson, Michael L.; Adkins, Susan L.; Ambur, Manjula Y.; Campbell, Bryan A.
1994-01-01
To demonstrate NASA Langley Research Center's relevance and to transfer technology to external customers in a timely and efficient manner, Langley has formed a working group to study and recommend a course of action for the electronic dissemination of technical reports (EDTR). The working group identified electronic report requirements (e.g., accessibility, file format, search requirements) of customers in U.S. industry through numerous site visits and personal contacts. Internal surveys were also used to determine commonalities in document preparation methods. From these surveys, a set of requirements for an electronic dissemination system was developed. Two candidate systems were identified and evaluated against the set of requirements: the Full-Text Electronic Documents System (FEDS), which is a full-text retrieval system based on the commercial document management package Interleaf, and the Langley Technical Report Server (LTRS), which is a Langley-developed system based on the publicly available World Wide Web (WWW) software system. Factors that led to the selection of LTRS as the vehicle for electronic dissemination included searching and viewing capability, current system operability, and client software availability for multiple platforms at no cost to industry. This report includes the survey results, evaluations, a description of the LTRS architecture, recommended policy statement, and suggestions for future implementations.
Implementing and Improving Automated Electronic Tumor Molecular Profiling
Staggs, David B.; Hackett, Lauren; Haberman, Erich; Tod, Mike; Levy, Mia; Warner, Jeremy
2016-01-01
Oncology practice increasingly requires the use of molecular profiling of tumors to inform the use of targeted therapeutics. However, many oncologists use third-party laboratories to perform tumor genomic testing, and these laboratories may not have electronic interfaces with the provider’s electronic medical record (EMR) system. The resultant reporting mechanisms, such as plain-paper faxing, can reduce report fidelity, slow down reporting procedures for a physician’s practice, and make reports less accessible. Vanderbilt University Medical Center and its genomic laboratory testing partner have collaborated to create an automated electronic reporting system that incorporates genetic testing results directly into the clinical EMR. This system was iteratively tested, and causes of failure were discovered and addressed. Most errors were attributable to data entry or typographical errors that made reports unable to be linked to the correct patient in the EMR. By providing direct feedback to providers, we were able to significantly decrease the rate of transmission errors (from 6.29% to 3.84%; P < .001). The results and lessons of 1 year of using the system and transmitting 832 tumor genomic testing reports are reported. PMID:26813927
30 CFR 210.54 - Must I submit this royalty report electronically?
Code of Federal Regulations, 2010 CFR
2010-07-01
... with which either party may contract. (2) Web-based reporting—Reporters/payors may enter report data directly or upload files using the MMS electronic web form located at http://www.mrmreports.net. The... generated from a reporter's system application. (c) Refer to our electronic reporting guidelines in the MMS...
NASA Technical Reports Server (NTRS)
Tuey, Richard C.; Collins, Mary; Caswell, Pamela; Haynes, Bob; Nelson, Michael L.; Holm, Jeanne; Buquo, Lynn; Tingle, Annette; Cooper, Bill; Stiltner, Roy
1996-01-01
This evaluation report contains an introduction, seven chapters, and five appendices. The Introduction describes the purpose, conceptual frame work, functional description, and technical report server of the STI Electronic Document Distribution (EDD) project. Chapter 1 documents the results of the prototype STI EDD in actual operation. Chapter 2 documents each NASA center's post processing publication processes. Chapter 3 documents each center's STI software, hardware, and communications configurations. Chapter 7 documents STI EDD policy, practices, and procedures. The appendices, which arc contained in Part 2 of this document, consist of (1) STI EDD Project Plan, (2) Team members, (3) Phasing Schedules, (4) Accessing On-line Reports, and (5) Creating an HTML File and Setting Up an xTRS. In summary, Stage 4 of the NASAwide Electronic Publishing System is the final phase of its implementation through the prototyping and gradual integration of each NASA center's electronic printing systems, desktop publishing systems, and technical report servers to be able to provide to NASA's engineers, researchers, scientists, and external users the widest practicable and appropriate dissemination of information concerning its activities and the result thereof to their work stations.
NASA Technical Reports Server (NTRS)
Tuey, Richard C.; Collins, Mary; Caswell, Pamela; Haynes, Bob; Nelson, Michael L.; Holm, Jeanne; Buquo, Lynn; Tingle, Annette; Cooper, Bill; Stiltner, Roy
1996-01-01
This evaluation report contains an introduction, seven chapters, and five appendices. The Introduction describes the purpose, conceptual framework, functional description, and technical report server of the Scientific and Technical Information (STI) Electronic Document Distribution (EDD) project. Chapter 1 documents the results of the prototype STI EDD in actual operation. Chapter 2 documents each NASA center's post processing publication processes. Chapter 3 documents each center's STI software, hardware. and communications configurations. Chapter 7 documents STI EDD policy, practices, and procedures. The appendices consist of (A) the STI EDD Project Plan, (B) Team members, (C) Phasing Schedules, (D) Accessing On-line Reports, and (E) Creating an HTML File and Setting Up an xTRS. In summary, Stage 4 of the NASAwide Electronic Publishing System is the final phase of its implementation through the prototyping and gradual integration of each NASA center's electronic printing systems, desk top publishing systems, and technical report servers, to be able to provide to NASA's engineers, researchers, scientists, and external users, the widest practicable and appropriate dissemination of information concerning its activities and the result thereof to their work stations.
77 FR 60108 - Atlantic Highly Migratory Species; Electronic Dealer Reporting System Workshop
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-02
... reporting system will allow dealers to submit Atlantic sharks, swordfish, and BAYS tuna data on a more real-time basis and more efficiently, and will reduce duplicative data submissions from different regions... are open to any interested parties. DATES: Training workshops for the new electronic dealer system...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-25
... Information and Regulatory Affairs, Office of Management and Budget, Attn: VA Desk Officer; 725 17th St. NW....'' SUPPLEMENTARY INFORMATION: Title: VA Loan Electronic Reporting Interface (VALERI) System. OMB Control Number... information submitted through the VALERI system to perform supplemental servicing, determination on...
Southwest Electronic One-Stop Shopping (EOSS) : field operational test : final evaluation report
DOT National Transportation Integrated Search
1999-06-01
This report presents an evaluation of the Southwest Electronic One-Stop Shopping System (EOSS) Operational Test. The system consisted of a PC-based software application that enabled interstate carriers to identify required commercial vehicle credenti...
78 FR 46005 - NPDES Electronic Reporting Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-30
... reports, and enforcement responses is provided (i.e., electronic rather than paper-based), it does not... is proposing a regulation that would require electronic reporting for current paper-based NPDES....regulations.gov Web site is an ``anonymous access'' system, which means EPA will not know your identity or...
Shah, Gulzar H; Leider, Jonathon P; Castrucci, Brian C; Williams, Karmen S; Luo, Huabin
2016-01-01
Assessing local health departments' (LHDs') informatics capacities is important, especially within the context of broader, systems-level health reform. We assessed a nationally representative sample of LHDs' adoption of information systems and the factors associated with adoption and implementation by examining electronic health records, health information exchange, immunization registry, electronic disease reporting system, and electronic laboratory reporting. We used data from the National Association of County and City Health Officials' 2013 National Profile of LHDs. We performed descriptive statistics and multinomial logistic regression for the five implementation-oriented outcome variables of interest, with three levels of implementation (implemented, plan to implement, and no activity). Independent variables included infrastructural and financial capacity and other characteristics associated with informatics capacity. Of 505 LHDs that responded to the survey, 69 (13.5%) had implemented health information exchanges, 122 (22.2%) had implemented electronic health records, 245 (47.5%) had implemented electronic laboratory reporting, 368 (73.0%) had implemented an electronic disease reporting system, and 416 (83.8%) had implemented an immunization registry. LHD characteristics associated with health informatics adoption included provision of greater number of clinical services, greater per capita public health expenditures, health information systems specialists on staff, larger population size, decentralized governance system, one or more local boards of health, metropolitan jurisdiction, and top executive with more years in the job. Many LHDs lack health informatics capacity, particularly in smaller, rural jurisdictions. Cross-jurisdictional sharing, investment in public health informatics infrastructure, and additional training may help address these shortfalls.
International Border Electronic Clearance -- IBEX : evaluation report
DOT National Transportation Integrated Search
1998-07-01
The International Border Electronic Crossing (IBEX) system implemented in this operational test was intended to demonstrate the integration of electronic information systems and technologies aimed at facilitating the safe, efficient movement of goods...
Review of Safety Reports Involving Electronic Flight Bags.
DOT National Transportation Integrated Search
2010-04-01
Safety events in which Electronic Flight Bags (EFBs) were a factor are reviewed. Relevant reports were obtained from the public Aviation Safety Reporting System (ASRS) database and the National Transportation Safety Board (NTSB) accident report datab...
2012-11-15
This final rule with comment period revises the Medicare hospital outpatient prospective payment system (OPPS) and the Medicare ambulatory surgical center (ASC) payment system for CY 2013 to implement applicable statutory requirements and changes arising from our continuing experience with these systems. In this final rule with comment period, we describe the changes to the amounts and factors used to determine the payment rates for Medicare services paid under the OPPS and those paid under the ASC payment system. In addition, this final rule with comment period updates and refines the requirements for the Hospital Outpatient Quality Reporting (OQR) Program, the ASC Quality Reporting (ASCQR) Program, and the Inpatient Rehabilitation Facility (IRF) Quality Reporting Program. We are continuing the electronic reporting pilot for the Electronic Health Record (EHR) Incentive Program, and revising the various regulations governing Quality Improvement Organizations (QIOs), including the secure transmittal of electronic medical information, beneficiary complaint resolution and notification processes, and technical changes. The technical changes to the QIO regulations reflect CMS' commitment to the general principles of the President's Executive Order on Regulatory Reform, Executive Order 13563 (January 18, 2011).
ERIC Educational Resources Information Center
Management and Information System for Occupational Education, Winchester, MA.
The reporting booklet is required for the Census Data System (CDS) of the Management Information System for Occupational Education (MISOE); it contains the reporting forms which collect data that describe program structure and job-entry skill outcomes expected of program completors in the individual occupational education area of electronics.…
Harle, Christopher A; Listhaus, Alyson; Covarrubias, Constanza M; Schmidt, Siegfried Of; Mackey, Sean; Carek, Peter J; Fillingim, Roger B; Hurley, Robert W
2016-01-01
In this case report, the authors describe the implementation of a system for collecting patient-reported outcomes and integrating results in an electronic health record. The objective was to identify lessons learned in overcoming barriers to collecting and integrating patient-reported outcomes in an electronic health record. The authors analyzed qualitative data in 42 documents collected from system development meetings, written feedback from users, and clinical observations with practice staff, providers, and patients. Guided by the Unified Theory on the Adoption and Use of Information Technology, 5 emergent themes were identified. Two barriers emerged: (i) uncertain clinical benefit and (ii) time, work flow, and effort constraints. Three facilitators emerged: (iii) process automation, (iv) usable system interfaces, and (v) collecting patient-reported outcomes for the right patient at the right time. For electronic health record-integrated patient-reported outcomes to succeed as useful clinical tools, system designers must ensure the clinical relevance of the information being collected while minimizing provider, staff, and patient burden. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Critical issues in an electronic documentation system.
Weir, Charlene R; Nebeker, Jonathan R
2007-10-11
The Veterans Health Administration (VHA), of the U.S. Department of Veteran Affairs has instituted a medical record (EMR) that includes electronic documentation of all narrative components of the medical record. To support clinicians using the system, multiple efforts have been instituted to ease the creation of narrative reports. Although electronic documentation is easier to read and improves access to information, it also may create new and additional hazards for users. This study is the first step in a series of studies to evaluate the issues surrounding the creation and use of electronic documentation. Eighty-eight providers across multiple clinical roles were interviewed in 10 primary care sites in the VA system. Interviews were tape-recorded, transcribed and qualitatively analyzed for themes. In addition, specific questions were asked about perceived harm due to electronic documentation practices. Five themes relating to difficulties with electronic documentation were identified: 1) information overload; 2) hidden information; 3) lack of trust; 4) communication; 5) decision-making. Three providers reported that they knew of an incident where current documentation practices had caused patient harm and over 75% of respondents reported significant mis-trust of the system.
Electronic clinical safety reporting system: a benefits evaluation.
Elliott, Pamela; Martin, Desmond; Neville, Doreen
2014-06-11
Eastern Health, a large health care organization in Newfoundland and Labrador (NL), started a staged implementation of an electronic occurrence reporting system (used interchangeably with "clinical safety reporting system") in 2008, completing Phase One in 2009. The electronic clinical safety reporting system (CSRS) was designed to replace a paper-based system. The CSRS involves reporting on occurrences such as falls, safety/security issues, medication errors, treatment and procedural mishaps, medical equipment malfunctions, and close calls. The electronic system was purchased from a vendor in the United Kingdom that had implemented the system in the United Kingdom and other places, such as British Columbia. The main objective of the new system was to improve the reporting process with the goal of improving clinical safety. The project was funded jointly by Eastern Health and Canada Health Infoway. The objectives of the evaluation were to: (1) assess the CSRS on achieving its stated objectives (particularly, the benefits realized and lessons learned), and (2) identify contributions, if any, that can be made to the emerging field of electronic clinical safety reporting. The evaluation involved mixed methods, including extensive stakeholder participation, pre/post comparative study design, and triangulation of data where possible. The data were collected from several sources, such as project documentation, occurrence reporting records, stakeholder workshops, surveys, focus groups, and key informant interviews. The findings provided evidence that frontline staff and managers support the CSRS, identifying both benefits and areas for improvement. Many benefits were realized, such as increases in the number of occurrences reported, in occurrences reported within 48 hours, in occurrences reported by staff other than registered nurses, in close calls reported, and improved timelines for notification. There was also user satisfaction with the tool regarding ease of use, accessibility, and consistency. The implementation process encountered challenges related to customizing the software and the development of the classification system for coding occurrences. This impacted on the ability of the managers to close-out files in a timely fashion. The issues that were identified, and suggestions for improvements to the form itself, were shared with the Project Team as soon as they were noted. Changes were made to the system before the rollout. There were many benefits realized from the new system that can contribute to improved clinical safety. The participants preferred the electronic system over the paper-based system. The lessons learned during the implementation process resulted in recommendations that informed the rollout of the system in Eastern Health, and in other health care organizations in the province of Newfoundland and Labrador. This study also informed the evaluation of other health organizations in the province, which was completed in 2013.
The new Electronic Grants Management System of the Space Telescope Science Institute
NASA Astrophysics Data System (ADS)
Beaser, R.; Wagner, E.
1999-12-01
The Space Telescope Science Institute has developed a new web-based Grants Management System which will be implemented at grantee institutions in the Spring of 2000. The system will feature on-line preparation and submission of budgets for all programs as well as e-mail notifications to Principal Investigators (PIs) and Authorizing Officials (AOs) of all Awards and Amendments. PDF versions of the documents will be available on the ST ScI web site. In addition, all financial and performance reports will be submitted via the web and grantees will be notified electronically of due and overdue reports. All administrative requests such as budget revisions, requests to extend the grant period, etc., will be submitted electronically to ST ScI. Detailed grant status information will be on-line and a variety of proposal and grant reports will be available to PIs and AOs. The system will also permit electronic routing of budgets and financial reports through the grantee institution.
Ndira, S P; Rosenberger, K D; Wetter, T
2008-01-01
To assess if electronic health record systems in developing countries can improve on timeliness, availability and accuracy of routine health reports and staff satisfaction after introducing the electronic system, compared to the paper-based alternative. The research was conducted with hospital staff of Tororo District Hospital in Uganda. A comparative intervention study with qualitative and quantitative methods was used to compare the paper-based (pre-test) to the electronic system (post-test) focusing on accuracy, availability and timeliness of monthly routine reports about mothers visiting the hospital; and staff satisfaction with the electronic system as outcome measures. Timeliness: pre-test 13 of 19 months delivered to the district timely, delivery dates for six months could not be established; post-test 100%. pre-test 79% of reports were present at the district health office; post-test 100%. Accuracy: pre-test 73.2% of selected reports could be independently confirmed as correct; post-test 71.2%. Difficulties were encountered in finding enough mothers through direct follow up to inquire on accuracy of information recorded about them. Staff interviews showed that the electronic system is appreciated by the majority of the hospital staff. Remaining obstacles include staff workload, power shortages, network breakdowns and parallel data entry (paper-based and electronic). While timeliness and availability improved, improvement of accuracy could not be established. Better approaches to ascertaining accuracy have to be devised, e.g. evaluation of intended use. For success, organizational, managerial and social challenges must be addressed beyond technical aspects.
Personal Electronic Devices and Their Interference with Aircraft Systems
NASA Technical Reports Server (NTRS)
Ross, Elden; Ely, Jay J. (Technical Monitor)
2001-01-01
A compilation of data on personal electronic devices (PEDs) attributed to having created anomalies with aircraft systems. Charts and tables display 14 years of incidents reported by pilots to the Aviation Safety Reporting System (ASRS). Affected systems, incident severity, sources of anomaly detection, and the most frequently identified PEDs are some of the more significant data. Several reports contain incidents of aircraft off course when all systems indicated on course and of critical events that occurred during landings and takeoffs. Additionally, PEDs that should receive priority in testing are identified.
EPA NetDMR CROMERR System Checklist
The Network Disharge Monitoring Report (NetDMR) electronic reporting system is used for the receipt of discharge monitoring reports (DMRs) under the National Pollutant Discharge Elimination System (NPDES) program,
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-15
... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0021] Agency Information Collection (VA Loan Electronic Reporting Interface (VALERI) System) Activity Under OMB Review AGENCY: Veterans Benefits... Administration (VBA), Department of Veterans Affairs, will submit the collection of information abstracted below...
11 CFR 104.18 - Electronic filing of reports (2 U.S.C. 432(d) and 434(a)(11)).
Code of Federal Regulations, 2012 CFR
2012-01-01
... specifications and can be read by the Commission's computer system. Each report submitted in an electronic format... 11 Federal Elections 1 2012-01-01 2012-01-01 false Electronic filing of reports (2 U.S.C. 432(d) and 434(a)(11)). 104.18 Section 104.18 Federal Elections FEDERAL ELECTION COMMISSION GENERAL REPORTS...
11 CFR 104.18 - Electronic filing of reports (2 U.S.C. 432(d) and 434(a)(11)).
Code of Federal Regulations, 2011 CFR
2011-01-01
... specifications and can be read by the Commission's computer system. Each report submitted in an electronic format... 11 Federal Elections 1 2011-01-01 2011-01-01 false Electronic filing of reports (2 U.S.C. 432(d) and 434(a)(11)). 104.18 Section 104.18 Federal Elections FEDERAL ELECTION COMMISSION GENERAL REPORTS...
11 CFR 104.18 - Electronic filing of reports (2 U.S.C. 432(d) and 434(a)(11)).
Code of Federal Regulations, 2013 CFR
2013-01-01
... specifications and can be read by the Commission's computer system. Each report submitted in an electronic format... 11 Federal Elections 1 2013-01-01 2012-01-01 true Electronic filing of reports (2 U.S.C. 432(d) and 434(a)(11)). 104.18 Section 104.18 Federal Elections FEDERAL ELECTION COMMISSION GENERAL REPORTS...
11 CFR 104.18 - Electronic filing of reports (2 U.S.C. 432(d) and 434(a)(11)).
Code of Federal Regulations, 2014 CFR
2014-01-01
... specifications and can be read by the Commission's computer system. Each report submitted in an electronic format... 11 Federal Elections 1 2014-01-01 2014-01-01 false Electronic filing of reports (2 U.S.C. 432(d) and 434(a)(11)). 104.18 Section 104.18 Federal Elections FEDERAL ELECTION COMMISSION GENERAL REPORTS...
30 CFR 1210.104 - Must I submit these production reports electronically?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (EDI)—The direct computer-to-computer interchange of data using standards set forth by the X12 American... be generated from a reporter's system application. (c) Refer to our electronic reporting guidelines...
Final NPDES Electronic Reporting Rule Fact Sheet
Fact sheet explaining the National Pollution Discharge Elimination System (NPDES) Electronic Reporting Rule. The fact sheet provides information on the purpose of the rule, benefits and implementation.
Electron spin polarization by isospin ordering in correlated two-layer quantum Hall systems.
Tiemann, L; Wegscheider, W; Hauser, M
2015-05-01
Enhancement of the electron spin polarization in a correlated two-layer, two-dimensional electron system at a total Landau level filling factor of 1 is reported. Using resistively detected nuclear magnetic resonance, we demonstrate that the electron spin polarization of two closely spaced two-dimensional electron systems becomes maximized when interlayer Coulomb correlations establish spontaneous isospin ferromagnetic order. This correlation-driven polarization dominates over the spin polarizations of competing single-layer fractional quantum Hall states under electron density imbalances.
Zbrozek, Arthur; Hebert, Joy; Gogates, Gregory; Thorell, Rod; Dell, Christopher; Molsen, Elizabeth; Craig, Gretchen; Grice, Kenneth; Kern, Scottie; Hines, Sheldon
2013-06-01
Outcomes research literature has many examples of high-quality, reliable patient-reported outcome (PRO) data entered directly by electronic means, ePRO, compared to data entered from original results on paper. Clinical trial managers are increasingly using ePRO data collection for PRO-based end points. Regulatory review dictates the rules to follow with ePRO data collection for medical label claims. A critical component for regulatory compliance is evidence of the validation of these electronic data collection systems. Validation of electronic systems is a process versus a focused activity that finishes at a single point in time. Eight steps need to be described and undertaken to qualify the validation of the data collection software in its target environment: requirements definition, design, coding, testing, tracing, user acceptance testing, installation and configuration, and decommissioning. These elements are consistent with recent regulatory guidance for systems validation. This report was written to explain how the validation process works for sponsors, trial teams, and other users of electronic data collection devices responsible for verifying the quality of the data entered into relational databases from such devices. It is a guide on the requirements and documentation needed from a data collection systems provider to demonstrate systems validation. It is a practical source of information for study teams to ensure that ePRO providers are using system validation and implementation processes that will ensure the systems and services: operate reliably when in practical use; produce accurate and complete data and data files; support management control and comply with any existing regulations. Furthermore, this short report will increase user understanding of the requirements for a technology review leading to more informed and balanced recommendations or decisions on electronic data collection methods. Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
DOT National Transportation Integrated Search
1998-05-01
The report examines the potential for developing electronic toll collection systems in Brazil. This is Volume III and it is 'Task-Recommendations and Final Report'. The report is made up of the following subtasks: (1) Issue Recommended Installation S...
BPM System for Electron Cooling in the Fermilab Recycler Ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joireman, Paul W.; Cai, Jerry; Chase, Brian E.
2004-11-10
We report a VXI based system used to acquire and process BPM data for the electron cooling system in the Fermilab Recycler ring. The BPM system supports acquisition of data from 19 BPM locations in five different sections of the electron cooling apparatus. Beam positions for both electrons and anti-protons can be detected simultaneously with a resolution of {+-}50 {mu}m. We calibrate the system independently for each beam type at each BPM location. We describe the system components, signal processing and modes of operation used in support of the electron-cooling project and present experimental results of system performance for themore » developmental electron cooling installation at Fermilab.« less
[Electronic poison information management system].
Kabata, Piotr; Waldman, Wojciech; Kaletha, Krystian; Sein Anand, Jacek
2013-01-01
We describe deployment of electronic toxicological information database in poison control center of Pomeranian Center of Toxicology. System was based on Google Apps technology, by Google Inc., using electronic, web-based forms and data tables. During first 6 months from system deployment, we used it to archive 1471 poisoning cases, prepare monthly poisoning reports and facilitate statistical analysis of data. Electronic database usage made Poison Center work much easier.
ERIC Educational Resources Information Center
Keenan, Thomas P.
Fifty gifted teenagers from across Canada, who were taught the Honeywell MULTICS "mail" and "forum" systems, were allowed free reign on an electronic communication system for several months. This paper reports on the students' use of the system, and on some of the interesting and unusual events which occurred during the course…
Advanced Clinical Decision Support for Vaccine Adverse Event Detection and Reporting.
Baker, Meghan A; Kaelber, David C; Bar-Shain, David S; Moro, Pedro L; Zambarano, Bob; Mazza, Megan; Garcia, Crystal; Henry, Adam; Platt, Richard; Klompas, Michael
2015-09-15
Reporting of adverse events (AEs) following vaccination can help identify rare or unexpected complications of immunizations and aid in characterizing potential vaccine safety signals. We developed an open-source, generalizable clinical decision support system called Electronic Support for Public Health-Vaccine Adverse Event Reporting System (ESP-VAERS) to assist clinicians with AE detection and reporting. ESP-VAERS monitors patients' electronic health records for new diagnoses, changes in laboratory values, and new allergies following vaccinations. When suggestive events are found, ESP-VAERS sends the patient's clinician a secure electronic message with an invitation to affirm or refute the message, add comments, and submit an automated, prepopulated electronic report to VAERS. High-probability AEs are reported automatically if the clinician does not respond. We implemented ESP-VAERS in December 2012 throughout the MetroHealth System, an integrated healthcare system in Ohio. We queried the VAERS database to determine MetroHealth's baseline reporting rates from January 2009 to March 2012 and then assessed changes in reporting rates with ESP-VAERS. In the 8 months following implementation, 91 622 vaccinations were given. ESP-VAERS sent 1385 messages to responsible clinicians describing potential AEs. Clinicians opened 1304 (94.2%) messages, responded to 209 (15.1%), and confirmed 16 for transmission to VAERS. An additional 16 high-probability AEs were sent automatically. Reported events included seizure, pleural effusion, and lymphocytopenia. The odds of a VAERS report submission during the implementation period were 30.2 (95% confidence interval, 9.52-95.5) times greater than the odds during the comparable preimplementation period. An open-source, electronic health record-based clinical decision support system can increase AE detection and reporting rates in VAERS. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
2008-01-30
Energy Fusion Cell, and allocations include $110 million for oil pipeline exclusion zones—which aim to prevent illegal tapping and sabotage of...sectors in Iraq. This quarter SIGIR highlights two of these programs: the electronic funds transfer ( EFT ) system and U.S. advisory support provided to...the Iraq Stock Exchange. eleCTroniC funds Transfer SIGIR noted last quarter that Iraq finally acti- vated an electronic funds transfer ( EFT ) system
2008-01-30
Cell, and allocations include $110 million for oil pipeline exclusion zones—which aim to prevent illegal tapping and sabotage of pipelines—$51...This quarter SIGIR highlights two of these programs: the electronic funds transfer ( EFT ) system and U.S. advisory support provided to the Iraq Stock...Exchange. eleCTroniC funds Transfer SIGIR noted last quarter that Iraq finally acti- vated an electronic funds transfer ( EFT ) system. The United
Antonacci, Anthony C; Lam, Steven; Lavarias, Valentina; Homel, Peter; Eavey, Roland D
2008-12-01
To study the profile of incidents affecting quality outcomes after surgery by developing a usable operating room and perioperative clinical incident report database and a functional electronic classification, triage, and reporting system. Previously, incident reports after surgery were handled on an individual, episodic basis, which limited the ability to perceive actuarial patterns and meaningfully improve outcomes. Clinical incident reports were experientially generated in the second largest health care system in New York City. Data were entered into a functional classification system organized into 16 categories, and weekly triage meetings were held to electronically review and report summaries on 40 to 60 incident reports per week. System development and deployment reviewed 1041 reports after 19,693 operative procedures. During the next 4 years, 3819 additional reports were generated from 83,988 operative procedures and were reported electronically to the appropriate departments. Number of incident reports generated annually. A significant decrease in volume-adjusted clinical incident reports occurred (from 53 to 39 reports per 1000 procedures) from 2001 to 2005 (P < .001). Reductions in incident reports were observed for ambulatory conversions (74% reduction), wasted implants (65%), skin breakdown (64%), complications in the operating room (42%), laparoscopic conversions (32%), and cancellations (23%) as a result of data-focused process and clinical interventions. Six of 16 categories of incident reports accounted for more than 88% of all incident reports. These data suggest that effective review, communication, and summary feedback of clinical incident reports can produce a statistically significant decrease in adverse outcomes.
NASA Electronic Library System (NELS) optimization
NASA Technical Reports Server (NTRS)
Pribyl, William L.
1993-01-01
This is a compilation of NELS (NASA Electronic Library System) Optimization progress/problem, interim, and final reports for all phases. The NELS database was examined, particularly in the memory, disk contention, and CPU, to discover bottlenecks. Methods to increase the speed of NELS code were investigated. The tasks included restructuring the existing code to interact with others more effectively. An error reporting code to help detect and remove bugs in the NELS was added. Report writing tools were recommended to integrate with the ASV3 system. The Oracle database management system and tools were to be installed on a Sun workstation, intended for demonstration purposes.
Simultaneous real-time data collection methods
NASA Technical Reports Server (NTRS)
Klincsek, Thomas
1992-01-01
This paper describes the development of electronic test equipment which executes, supervises, and reports on various tests. This validation process uses computers to analyze test results and report conclusions. The test equipment consists of an electronics component and the data collection and reporting unit. The PC software, display screens, and real-time data-base are described. Pass-fail procedures and data replay are discussed. The OS2 operating system and Presentation Manager user interface system were used to create a highly interactive automated system. The system outputs are hardcopy printouts and MS DOS format files which may be used as input for other PC programs.
Software Intensive Systems Cost and Schedule Estimation
2013-06-13
Radio communication systems RTE Electronic navigation systems RTE Space vehicle electronic tracking systems RTE Sonar systems RTE...MONITORING AGENCY NAME(S) AND ADDRESS(ES) DASD (SE), DoD, AIRFORCE 10. SPONSOR/MONITOR’S ACRONYM(S) 11 . SPONSOR/MONITOR’S REPORT NUMBER(S) 12... 11 3.2.2 SEER‐SEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
McElroy, Robert Dennis
From the 1991 until 2008 the Canberra Hybrid K-Edge Densitometer systems were provided with ICB-NIM (Integrated Control Bus – Nuclear Instrument Module) acquisition electronics. Newer electronics modules, such as the Lynx, were not supported under the VMS based operating system. The LYNX module was provided as the standard acquisition electronics following the release of the Windows based CHKED software. This report compares the electronics dead-time, gain shifts, detector resolution and measurement performance of the HKED system operated with the two types of acquisition modules. The comparison was performed using measurements obtained with the ORNL HKED system. The original intent ofmore » this study was to take advantage of both the timing and energy outputs from the HPGE detector to acquire data with both sets of electronics in parallel. Although this approach has been applied successfully with other systems, in this case we found the timing output produced a significant amount of noise such that a comparison between the electronics would be invalid. So the comparative measurements were performed sequentially. The ICB-NIM data was acquired over the course of 12 months with 255 measurements while the LYNX data was acquired over a period of 10 months with 75 measurements. To simplify the comparison, all data used in this study was acquired using the Canberra CHKED (V1.0) software package. The performance analysis was based primarily on the peak locations, peak widths and concentration values reported by the CHKED software. The raw spectra from the XRF measurements were also examined to extract additional 109Cd peak location and width data for the hybrid measurements (the standard hybrid report template does not report these values).« less
Effect of electronic report writing on the quality of nursing report recording
Heidarizadeh, Khadijeh; Rassouli, Maryam; Manoochehri, Houman; Tafreshi, Mansoureh Zagheri; Ghorbanpour, Reza Kashef
2017-01-01
Background and Aim Recording performed nursery actions is one of the main chores of nurses. The findings have shown that recorded reports are not qualitatively valid. Since electronic reports can be regarded as a base to write reports, this study aims at determining the effect of utilizing electronic nursing reports on the quality of the records. Methods This quasi-experimental study was conducted with the aim of applying an electronic system of nursing recording in the heart department of Shahid Rahimi Medical Center, Lorestan University of Medical Science. The samples were nursing reports on the hospitalized patients in the heart department, the basis of complete enumeration (census) during the fall of 2014. The subjects were sixteen employed nurses. To do the study, the software of nursing records was set based on the Clinical Care Classification system (CCC). The research’s tool was the checklist of the Standards of Nursing Documentation. Results The findings indicated that before and after the intervention, the amount of reports’ adaption with the written standards, respectively, was (21.8%) and (71.3%), and the most complete recording was medicine status (58%) and (100%). The worst complete recording before the intervention, acute changes was (99.1%) and nursing processes was (78%) and after, the medicine status, intake and output status and patient’s education (100%); while the nursing report structure was regarded in all cases (100%). The results showed that there is a significant difference in the quality of reporting before and after using CCC (p<0.001). Conclusions Since the necessary parameters for recording a standard report do exist in electronic reporting (CCC), from one point, nurses are reminded to record the necessary parts and from the other point, the system does not allow the user to shut it down unless the necessary parameters are recorded. For this reason, the quality of recorded reports with electronic reporting improves. PMID:29238481
NASA Technical Reports Server (NTRS)
Dawe, R. H.; Arnett, J. C.
1974-01-01
Electronic packaging and cabling activities performed in support of the Thermoelectric Outer Planets Spacecraft (TOPS) Advanced Systems Technology (AST) project are detailed. It describes new electronic compartment, electronic assembly, and module concepts, and a new high-density, planar interconnection technique called discrete multilayer (DML). Development and qualification of high density cabling techniques, using small gage wire and microminiature connectors, are also reported.
This Economic Analysis (EA) quantifies the costs and savings of the proposed NPDES Electronic Reporting Rule, while acknowledging many of the qualitative benefits that will result from its implementation.
Potential of spark ignition engine, electronic engine and transmission control : final report
DOT National Transportation Integrated Search
1980-03-01
This report identifies, evaluates, and documents the characteristics and functions of significant electronic engine and powertrain control systems. Important considerations in the assessment are the powertrain variables controlled, the technology uti...
Sauer, Vernon B.
2002-01-01
Surface-water computation methods and procedures are described in this report to provide standards from which a completely automated electronic processing system can be developed. To the greatest extent possible, the traditional U. S. Geological Survey (USGS) methodology and standards for streamflow data collection and analysis have been incorporated into these standards. Although USGS methodology and standards are the basis for this report, the report is applicable to other organizations doing similar work. The proposed electronic processing system allows field measurement data, including data stored on automatic field recording devices and data recorded by the field hydrographer (a person who collects streamflow and other surface-water data) in electronic field notebooks, to be input easily and automatically. A user of the electronic processing system easily can monitor the incoming data and verify and edit the data, if necessary. Input of the computational procedures, rating curves, shift requirements, and other special methods are interactive processes between the user and the electronic processing system, with much of this processing being automatic. Special computation procedures are provided for complex stations such as velocity-index, slope, control structures, and unsteady-flow models, such as the Branch-Network Dynamic Flow Model (BRANCH). Navigation paths are designed to lead the user through the computational steps for each type of gaging station (stage-only, stagedischarge, velocity-index, slope, rate-of-change in stage, reservoir, tide, structure, and hydraulic model stations). The proposed electronic processing system emphasizes the use of interactive graphics to provide good visual tools for unit values editing, rating curve and shift analysis, hydrograph comparisons, data-estimation procedures, data review, and other needs. Documentation, review, finalization, and publication of records are provided for with the electronic processing system, as well as archiving, quality assurance, and quality control.
Real-time measurement and monitoring of absorbed dose for electron beams
NASA Astrophysics Data System (ADS)
Korenev, Sergey; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon
2004-09-01
The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators.
Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh
2016-04-01
Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. to determine the minimum data set of echocardiography reporting system to exchange with Iran's electronic health record (EHR) system. First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients' records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. The highest degree of consensus was found for the following MDSs: patient's name and family name (5), accepting doctor's name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran's electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider.
TRANSMIT system evaluation : final report
DOT National Transportation Integrated Search
1998-06-30
This report presents the evaluation results of TRANSCOMs System for Managing Incidents and Traffic (TRANSMIT). The TRANSMIT system utilizes Electronic Toll and Traffic Management (ETTM) equipment, which is compatible with the E-Z Pass system, for ...
Mei, Yi You; Marquard, Jenna; Jacelon, Cynthia; DeFeo, Audrey L
2013-11-01
Patient falls are the leading cause of unintentional injury and death among older adults. In 2000, falls resulted in over 10,300 elderly deaths, costing the United States approximately $179 million in incidence and medical costs. Furthermore, non-fatal injuries caused by falls cost the United States $19 billion annually. Health information technology (IT) applications, specifically electronic falls reporting systems, can aid quality improvement efforts to prevent patient falls. Yet, long-term residential care facilities (LTRCFs) often do not have the financial resources to implement health IT, and workers in these settings are often not ready to adopt such systems. Additionally, most health IT evaluations are conducted in large acute-care settings, so LTRCF administrators currently lack evidence to support the value of health IT. In this paper, we detail the development of a novel, easy-to-use system to facilitate electronic patient falls reporting within a LTRCF using off-the-shelf technology that can be inexpensively implemented in a wide variety of settings. We report the results of four complimentary system evaluation measures that take into consideration varied organizational stakeholders' perspectives: (1) System-level benefits and costs, (2) system usability, via scenario-based use cases, (3) a holistic assessment of users' physical, cognitive, and marcoergonomic (work system) challenges in using the system, and (4) user technology acceptance. We report the viability of collecting and analyzing data specific to each evaluation measure and detail the relative merits of each measure in judging whether the system is acceptable to each stakeholder. The electronic falls reporting system was successfully implemented, with 100% reporting at 3-months post-implementation. The system-level benefits and costs approach showed that the electronic system required no initial investment costs aside from personnel costs and significant benefits accrued from user time savings. The usability analysis revealed several fixable design flaws and demonstrated the importance of scenario-based user training. The technology acceptance model showed that users perceived the reporting system to be useful and easy to use, even more so after implementation. Finally, the holistic human factors evaluation identified challenges encountered when nurses used the system as a part of their daily work, guiding further system redesign. The four-pronged evaluation framework accounted for varied stakeholder perspectives and goals and is a highly scalable framework that can be easily applied to health IT implementations in other LTRCFs. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Electronic systems failures and anomalies attributed to electromagnetic interference
NASA Technical Reports Server (NTRS)
Leach, R. D. (Editor); Alexander, M. B. (Editor)
1995-01-01
The effects of electromagnetic interference can be very detrimental to electronic systems utilized in space missions. Assuring that subsystems and systems are electrically compatible is an important engineering function necessary to assure mission success. This reference publication will acquaint the reader with spacecraft electronic systems failures and anomalies caused by electromagnetic interference and will show the importance of electromagnetic compatibility activities in conjunction with space flight programs. It is also hoped that the report will illustrate that evolving electronic systems are increasingly sensitive to electromagnetic interference and that NASA personnel must continue to diligently pursue electromagnetic compatibility on space flight systems.
10 CFR 61.80 - Maintenance of records, reports, and transfers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... receipt and disposal of radioactive waste in an electronic recordkeeping system. (1) The manifest... RADIOACTIVE WASTE Records, Reports, Tests, and Inspections § 61.80 Maintenance of records, reports, and.... The record may also be stored in electronic media with the capability for producing legible, accurate...
49 CFR 171.16 - Detailed hazardous materials incident reports.
Code of Federal Regulations, 2014 CFR
2014-10-01
... quantity of hazardous waste; (3) A specification cargo tank with a capacity of 1,000 gallons or greater..., DC 20590-0001, or an electronic Hazardous Material Incident Report to the Information System Manager..., submit a written or electronic copy of the Hazardous Materials Incident Report to the FAA Security Field...
49 CFR 171.16 - Detailed hazardous materials incident reports.
Code of Federal Regulations, 2012 CFR
2012-10-01
... quantity of hazardous waste; (3) A specification cargo tank with a capacity of 1,000 gallons or greater..., DC 20590-0001, or an electronic Hazardous Material Incident Report to the Information System Manager..., submit a written or electronic copy of the Hazardous Materials Incident Report to the FAA Security Field...
49 CFR 171.16 - Detailed hazardous materials incident reports.
Code of Federal Regulations, 2013 CFR
2013-10-01
... quantity of hazardous waste; (3) A specification cargo tank with a capacity of 1,000 gallons or greater..., DC 20590-0001, or an electronic Hazardous Material Incident Report to the Information System Manager..., submit a written or electronic copy of the Hazardous Materials Incident Report to the FAA Security Field...
47 CFR 27.20 - Digital television transition education reports.
Code of Federal Regulations, 2013 CFR
2013-10-01
... filed electronically using the Commission's Electronic Comment File System (ECFS), the “Document Type...—the licensee holding such authorization must file a report with the Commission indicating whether, in... April-June quarter of 2008, the licensee must file its first report by July 10, 2008. Each quarterly...
47 CFR 27.20 - Digital television transition education reports.
Code of Federal Regulations, 2012 CFR
2012-10-01
... filed electronically using the Commission's Electronic Comment File System (ECFS), the “Document Type...—the licensee holding such authorization must file a report with the Commission indicating whether, in... April-June quarter of 2008, the licensee must file its first report by July 10, 2008. Each quarterly...
12 CFR 620.10 - Preparing the quarterly report.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 620.10 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM DISCLOSURE TO SHAREHOLDERS... must: (1) Prepare and send, to the Farm Credit Administration, an electronic copy of its quarterly...) Publish a copy of its quarterly report on its Web site when it electronically sends the report to the Farm...
[Implementation of a form for adverse effect notification: results for the 1st year].
Pérez Blanco, Verónica; Rubio Gómez, Isabel; Alarcón Gascueña, Piedad; Mateos Rubio, José; Herradón Cano, Matilde; Delgado García, Amadeo
2009-02-01
To describe the introduction of an incident monitoring system by electronic reporting in the Complejo Hospitalario de Toledo (CHT) and to analyse the initial results. CHT is a public hospital with 750 beds, 59 for critical patients, an ambulatory surgery unit and three outpatient clinics. Access to the electronic reporting system is on the main screen of the hospital intranet. The reporting system is voluntary and confidential. It was introduced at the same time as setting up website on clinical safety and the provision of specific training on the subject. A total of 62 reports were received on the electronic system over a period of 12 months (December 2006 to December 2007), of which 74.5% were reported by nursing staff. The service from where it was reported most often was Geriatrics (43.1%). Most of the incidents were classified by the notifiers themselves as "no injury" (64.7%) and as "avoidable" 92.2%. A total of 56.9% were related to care. Some reports led to the issuing of three documents of recommendations by the Quality Unit and the Pharmacy Department. Most of the notifications were incidents related to care and were reported by nurses. The reporting system can complement other tools in promoting a clinical safety culture and defining the risk profile of a health organisation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leigh, Richard J.
2012-09-01
The Electronic Maintenance Report forms allow Local Maintenance Providers (LMP) and other program staff to enter maintenance information into a simple and secure system. This document describes the features and information required to complete the Maintenance Report forms. It is expected that all Corrective Maintenance Reports from LMPs will be submitted electronically into the SLD Portal. As an exception (e.g., when access to the SLD Portal is unavailable), Maintenance Reports can be submitted via a secure Adobe PDF form available through the Sustainability Manager assigned to each country.
Mutic, Sasa; Brame, R Scott; Oddiraju, Swetha; Parikh, Parag; Westfall, Melisa A; Hopkins, Merilee L; Medina, Angel D; Danieley, Jonathan C; Michalski, Jeff M; El Naqa, Issam M; Low, Daniel A; Wu, Bin
2010-09-01
The value of near-miss and error reporting processes in many industries is well appreciated and typically can be supported with data that have been collected over time. While it is generally accepted that such processes are important in the radiation therapy (RT) setting, studies analyzing the effects of organized reporting and process improvement systems on operation and patient safety in individual clinics remain scarce. The purpose of this work is to report on the design and long-term use of an electronic reporting system in a RT department and compare it to the paper-based reporting system it replaced. A specifically designed web-based system was designed for reporting of individual events in RT and clinically implemented in 2007. An event was defined as any occurrence that could have, or had, resulted in a deviation in the delivery of patient care. The aim of the system was to support process improvement in patient care and safety. The reporting tool was designed so individual events could be quickly and easily reported without disrupting clinical work. This was very important because the system use was voluntary. The spectrum of reported deviations extended from minor workflow issues (e.g., scheduling) to errors in treatment delivery. Reports were categorized based on functional area, type, and severity of an event. The events were processed and analyzed by a formal process improvement group that used the data and the statistics collected through the web-based tool for guidance in reengineering clinical processes. The reporting trends for the first 24 months with the electronic system were compared to the events that were reported in the same clinic with a paper-based system over a seven-year period. The reporting system and the process improvement structure resulted in increased event reporting, improved event communication, and improved identification of clinical areas which needed process and safety improvements. The reported data were also useful for the evaluation of corrective measures and recognition of ineffective measures and efforts. The electronic system was relatively well accepted by personnel and resulted in minimal disruption of clinical work. Event reporting in the quarters with the fewest number of reported events, though voluntary, was almost four times greater than the most events reported in any one quarter with the paper-based system and remained consistent from the inception of the process through the date of this report. However, the acceptance was not universal, validating the need for improved education regarding reporting processes and systematic approaches to reporting culture development. Specially designed electronic event reporting systems in a radiotherapy setting can provide valuable data for process and patient safety improvement and are more effective reporting mechanisms than paper-based systems. Additional work is needed to develop methods that can more effectively utilize reported data for process improvement, including the development of standardized event taxonomy and a classification system for RT.
Timeliness of notification systems for infectious diseases: A systematic literature review.
Swaan, Corien; van den Broek, Anouk; Kretzschmar, Mirjam; Richardus, Jan Hendrik
2018-01-01
Timely notification of infectious diseases is crucial for prompt response by public health services. Adequate notification systems facilitate timely notification. A systematic literature review was performed to assess outcomes of studies on notification timeliness and to determine which aspects of notification systems are associated with timely notification. Articles reviewing timeliness of notifications published between 2000 and 2017 were searched in Pubmed and Scopus. Using a standardized notification chain, timeliness of reporting system for each article was defined as either sufficient (≥ 80% notifications in time), partly sufficient (≥ 50-80%), or insufficient (< 50%) according to the article's predefined timeframe, a standardized timeframe for all articles, and a disease specific timeframe. Electronic notification systems were compared with conventional methods (postal mail, fax, telephone, email) and mobile phone reporting. 48 articles were identified. In almost one third of the studies with a predefined timeframe (39), timeliness of notification systems was either sufficient or insufficient (11/39, 28% and 12/39, 31% resp.). Applying the standardized timeframe (45 studies) revealed similar outcomes (13/45, 29%, sufficient notification timeframe, vs 15/45, 33%, insufficient). The disease specific timeframe was not met by any study. Systems involving reporting by laboratories most often complied sufficiently with predefined or standardized timeframes. Outcomes were not related to electronic, conventional notification systems or mobile phone reporting. Electronic systems were faster in comparative studies (10/13); this hardly resulted in sufficient timeliness, neither according to predefined nor to standardized timeframes. A minority of notification systems meets either predefined, standardized or disease specific timeframes. Systems including laboratory reporting are associated with timely notification. Electronic systems reduce reporting delay, but implementation needs considerable effort to comply with notification timeframes. During outbreak threats, patient, doctors and laboratory testing delays need to be reduced to achieve timely detection and notification. Public health authorities should incorporate procedures for this in their preparedness plans.
Holch, P; Warrington, L; Bamforth, L C A; Keding, A; Ziegler, L E; Absolom, K; Hector, C; Harley, C; Johnson, O; Hall, G; Morris, C; Velikova, G
2017-09-01
Significant adverse events (AE) during cancer therapy disrupt treatment and escalate to emergency admissions. Approaches to improve the timeliness and accuracy of AE reporting may improve safety and reduce health service costs. Reporting AE via patient reported outcomes (PROs), can improve clinician-patient communication and making data available to clinicians in 'real-time' using electronic PROs (ePROs) could potentially transform clinical practice by providing easily accessible records to guide treatment decisions. This manuscript describes the development of eRAPID (electronic patient self-Reporting of Adverse-events: Patient Information and aDvice) is a National Institute for Health Research-funded programme, a system for patients to self-report and manage AE online during and after cancer treatment. A multidisciplinary team of IT experts, staff and patients developed using agile principles a secure web application interface (QStore) between an existing online questionnaire builder (QTool) displaying real-time ePRO data to clinicians in the electronic patient record at Leeds Teaching Hospitals NHS Trust. Hierarchical algorithms were developed corresponding to Common Terminology Criteria for Adverse Events grading using the QTool question dependency function. Patient advocates (N = 9), patients (N = 13), and staff (N = 19) usability tested the system reporting combinations of AE. The eRAPID system allows patients to report AE from home on PC, tablet or any web enabled device securely during treatment. The system generates immediate self-management advice for low or moderate AE and for severe AE advice to contact the hospital immediately. Clinicians can view patient AE data in the electronic patient record and receive email notifications when patients report severe AE. Evaluation of the system in a randomised controlled trial in breast, gynaecological and colorectal cancer patients undergoing systemic therapy is currently underway. To adapt eRAPID for different treatment groups, pilot studies are being undertaken with patients receiving pelvic radiotherapy and upper gastrointestinal surgery. ISRCTN88520246. © The Author 2017. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOT National Transportation Integrated Search
2005-12-02
In 1998, ITS America established a Blue Ribbon Panel on electronic commerce to study the convergence of transportation and electronic payment systems. Panel members included senior managers from government, toll agencies, motor carrier industry, and ...
Cost/benefit analysis of electronic license plates
DOT National Transportation Integrated Search
2008-06-01
The objective of this report is to determine whether electronic vehicle recognition systems (EVR) or automatic license plate recognition systems (ALPR) would be beneficial to the Arizona Department of Transportation (AZDOT). EVR uses radio frequency ...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 232.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7003 Procedures. (a) The accepted electronic form for...
48 CFR 232.7001 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 232.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7001 Definitions. Electronic form and payment request...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 232.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7003 Procedures. (a) The accepted electronic form for...
48 CFR 232.7001 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 232.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7001 Definitions. Electronic form and payment request...
48 CFR 232.7001 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 232.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7001 Definitions. Electronic form and payment request...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 232.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7003 Procedures. (a) The accepted electronic form for...
48 CFR 232.7001 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 232.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7001 Definitions. Electronic form and payment request...
48 CFR 232.7001 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 232.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7001 Definitions. Electronic form and payment request...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 232.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7003 Procedures. (a) The accepted electronic form for...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 232.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7003 Procedures. (a) The accepted electronic form for...
Clothing hanger injuries: pediatric head and neck traumas in the United States, 2002-2012.
Walls, Andrew; Pierce, Matthew; Wang, Hongkun; Harley, Earl H
2014-02-01
To discuss pediatric clothing hanger injuries and review the National Electronic Injury Surveillance System to elucidate frequency and promote increased public awareness among pediatric otolaryngologists. Cross-sectional analysis of a national database. National Electronic Injury Surveillance System Database. A retrospective review of the National Electronic Injury Surveillance System provided a nationally weighted sampling estimate of 394 pediatric incident reports involving clothing hangers. Each incident report was analyzed for impalement, facial laceration, and contusion injuries to the mouth, face, and head. In addition, hospital disposition and location of the described incident were also obtained. Upon review of the National Electronic Injury Surveillance System, incident rates of pediatric oral impalement (95% confidence interval [CI], 0.10-0.41), facial laceration (95% CI, 0.22-0.41), and facial abrasion injuries (95% CI, 0.15-0.44) frequently involved the metal clothing hanger design. In addition, most of the reported injuries occurred within the home and involved lacerations to the oral cavity. This is the first multiyear, nationally representative study to analyze clothing hanger injuries in the pediatric population. We demonstrate that these injuries occur more frequently than the medical literature currently reports and also elucidate that children are more likely to obtain laceration injuries by metal clothing hangers within the home. Furthermore, we provide a recommendation for standardization of the National Electronic Injury Surveillance System such that product safety analysis may occur and reduce further pediatric incidents.
Interconnection of electronic medical record with clinical data management system by CDISC ODM.
Matsumura, Yasushi; Hattori, Atsushi; Manabe, Shiro; Takeda, Toshihiro; Takahashi, Daiyo; Yamamoto, Yuichiro; Murata, Taizo; Mihara, Naoki
2014-01-01
EDC system has been used in the field of clinical research. The current EDC system does not connect with electronic medical record system (EMR), thus a medical staff has to transcribe the data in EMR to EDC system manually. This redundant process causes not only inefficiency but also human error. We developed an EDC system cooperating with EMR, in which the data required for a clinical research form (CRF) is transcribed automatically from EMR to electronic CRF (eCRF) and is sent via network. We call this system as "eCRF reporter". The interface module of eCRF reporter can retrieves the data in EMR database including patient biography data, laboratory test data, prescription data and data entered by template in progress notes. The eCRF reporter also enables users to enter data directly to eCRF. The eCRF reporter generates CDISC ODM file and PDF which is a translated form of Clinical data in ODM. After storing eCRF in EMR, it is transferred via VPN to a clinical data management system (CDMS) which can receive the eCRF files and parse ODM. We started some clinical research by using this system. This system is expected to promote clinical research efficiency and strictness.
A summary of the research program in the broad field of electronics
NASA Technical Reports Server (NTRS)
1972-01-01
Summary reports of research projects covering solid state materials, semiconductors and devices, quantum electronics, plasmas, applied electromagnetics, electrical engineering systems to include control communication, computer and power systems, biomedical engineering and mathematical biosciences.
Assessment of Safety Standards for Automotive Electronic Control Systems
DOT National Transportation Integrated Search
2016-06-01
This report summarizes the results of a study that assessed and compared six industry and government safety standards relevant to the safety and reliability of automotive electronic control systems. These standards include ISO 26262 (Road Vehicles - ...
Review of safety reports involving electronic flight bags
DOT National Transportation Integrated Search
2009-04-27
Electronic Flight Bags (EFBs) are a relatively new device used by pilots. Even so, 37 safety-related events involving EFBs were identified from the public online Aviation Safety Reporting System (ASRS) database as of June 2008. In addition, two accid...
Audit of radiology communication systems for critical, urgent, and unexpected significant findings.
Duncan, K A; Drinkwater, K J; Dugar, N; Howlett, D C
2016-03-01
To determine the compliance of UK radiology departments and trusts/healthcare organisations with National Patient Safety Agency and Royal College of Radiologist's published guidance on the communication of critical, urgent, and unexpected significant radiological findings. A questionnaire was sent to all UK radiology department audit leads asking for details of their current departmental policy regarding the issuing of alerts; use of automated electronic alert systems; methods of notification of clinicians of critical, urgent, and unexpected significant radiological findings; monitoring of results receipt; and examples of the more common types of serious pathologies for which alerts were issued. One hundred and fifty-four of 229 departments (67%) responded. Eighty-eight percent indicated that they had a policy in place for the communication of critical, urgent, and unexpected significant radiological findings. Only 34% had an automated electronic alert system in place and only 17% had a facility for service-wide electronic tracking of radiology reports. In only 11 departments with an electronic acknowledgement system was someone regularly monitoring the read rate. There is wide variation in practice across the UK with regard to the communication and monitoring of reports with many departments/trusts not fully compliant with published UK guidance. Despite the widespread use of electronic systems, only a minority of departments/trusts have and use electronic tracking to ensure reports have been read and acted upon. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Perez, Raymond P; Finnigan, Shanda; Patel, Krupa; Whitney, Shanell; Forrest, Annemarie
2016-12-15
Use of electronic clinical trial portals has increased in recent years to assist with sponsor-investigator communication, safety reporting, and clinical trial management. Electronic portals can help reduce time and costs associated with processing paperwork and add security measures; however, there is a lack of information on clinical trial investigative staff's perceived challenges and benefits of using portals. The Clinical Trials Transformation Initiative (CTTI) sought to (1) identify challenges to investigator receipt and management of investigational new drug (IND) safety reports at oncologic investigative sites and coordinating centers and (2) facilitate adoption of best practices for communicating and managing IND safety reports using electronic portals. CTTI, a public-private partnership to improve the conduct of clinical trials, distributed surveys and conducted interviews in an opinion-gathering effort to record investigator and research staff views on electronic portals in the context of the new safety reporting requirements described in the US Food and Drug Administration's final rule (Code of Federal Regulations Title 21 Section 312). The project focused on receipt, management, and review of safety reports as opposed to the reporting of adverse events. The top challenge investigators and staff identified in using individual sponsor portals was remembering several complex individual passwords to access each site. Also, certain tasks are time-consuming (eg, downloading reports) due to slow sites or difficulties associated with particular operating systems or software. To improve user experiences, respondents suggested that portals function independently of browsers and operating systems, have intuitive interfaces with easy navigation, and incorporate additional features that would allow users to filter, search, and batch safety reports. Results indicate that an ideal system for sharing expedited IND safety information is through a central portal used by all sponsors. Until this is feasible, electronic reporting portals should at least have consistent functionality. CTTI has issued recommendations to improve the quality and use of electronic portals. ©Raymond P Perez, Shanda Finnigan, Krupa Patel, Shanell Whitney, Annemarie Forrest. Originally published in JMIR Cancer (http://cancer.jmir.org), 15.12.2016.
Some performance tests of a microarea AES. [Auger Electron Spectroscopy
NASA Technical Reports Server (NTRS)
Todd, G.; Poppa, H.
1978-01-01
An Auger electron spectroscopy (AES) system which has a submicron analysis capability is described. The system provides secondary electron imaging, as well as micro- and macro-area AES. The resolution of the secondary electron image of an oxidized Al contact pad on a charge-coupled device chip indicates a primary beam size of about 1000 A. For Auger mapping, a useful resolution of about 4000 A is reported
Electronic availability of microgravity experiments safety and integration requirements documents
NASA Technical Reports Server (NTRS)
Hogan, Jean M.
1995-01-01
This follow-on to NASA Contractor Report 195447, Microgravity Experiments Safety and Integration Requirements Document Tree, provides the details for accessing the systems that contain the official, electronic versions of the documents initially researched in NASA Contractor Report 195447. The data in this report serves as a valuable information source for the NASA Lewis Research Center Project Documentation Center (PDC), as well as for all developers of space experiments. The PDC has acquired the hardware, software, ID's, and passwords necessary to access most of these systems and is now able to provide customers with current document information as well as immediate delivery of available documents in either electronic or hard copy format.
DOT National Transportation Integrated Search
2005-07-29
In 1998, ITS America established a Blue Ribbon Panel on electronic commerce to study the convergence of transportation and electronic payment systems. Panel members included senior managers from government, toll agencies, motor carrier industry, and ...
Hexavalent Chrome Free Coatings for Electronics Applications: Joint Test Report
NASA Technical Reports Server (NTRS)
Rothgeb, Matt; Kessel, Kurt
2013-01-01
The overall objective of the Hexavalent Chrome Free Coatings for Electronics Applications project is to evaluate and test pretreatments not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders.
Barger, Diana; Leleux, Olivier; Conte, Valérie; Sapparrart, Vincent; Gapillout, Marie; Crespel, Isabelle; Erramouspe, Marie; Delveaux, Sandrine; Dabis, Francois; Bonnet, Fabrice
2018-06-07
Effective antiretroviral therapy has greatly reduced HIV-related morbidity and mortality, dramatically changing the demographics of the population of people living with HIV. The majority of people living with HIV in France are well cared for insofar as their HIV infection is concerned but remain at risk for age-associated comorbidities. Their long-term, potentially complex, and growing care needs make the routine, longitudinal assessment of health-related quality of life and other patient-reported outcomes of relevance in the current treatment era. We aim to describe the development of a Web-based electronic patient-reported outcomes system for people living with HIV linked to the ANRS CO3 Aquitaine cohort's data capture and visualization system (ARPEGE) and designed to facilitate the electronic collection of patient-reported data and ultimately promote better patient-physician communication and quality of care (both patient satisfaction and health outcomes). Participants who meet the eligibility criteria will be invited to engage with the Web-based electronic patient-reported outcomes system and provided with the information necessary to create a personal patient account. They will then be able to access the electronic patient-reported outcomes system and complete a set of standardized validated questionnaires covering health-related quality of life (World Health Organization's Quality of Life Instrument in HIV infection, named WHOQOL-HIV BREF) and other patient-reported outcomes. The information provided via questionnaires will ultimately be presented in a summary format for clinicians, together with the patient's HIV care history. The prototype of the Web-based electronic patient-reported outcome system will be finalized and the first 2 formative research phases of the study (prototyping and usability testing) will be conducted from December 2017 to May 2018. We describe the sequential processes planned to ensure that the proposed electronic patient-reported outcome system is ready for formal pilot testing, referred to herein as phases 1a and 1b. We also describe the planned pilot-testing designed to evaluate the acceptability and use of the system from the patient's perspective (phase 2). As the underlying information technology solution, ARPEGE, has being developed in-house, should the feasibility study presented here yield promising results, the panel of services provided via the proposed portal could ultimately be expanded and used to experiment with health-promoting interventions in aging people living with HIV in hospital-based care or adapted for use in other patient populations. ClinicalTrials.gov NCT03296202; https://clinicaltrials.gov/ct2/show/NCT03296202 (Archived by WebCite at http://www.webcitation.org/6zgOBArps). RR1-10.2196/9439. ©Diana Barger, Olivier Leleux, Valérie Conte, Vincent Sapparrart, Marie Gapillout, Isabelle Crespel, Marie Erramouspe, Sandrine Delveaux, Francois Dabis, Fabrice Bonnet. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 07.06.2018.
Automatic Thesaurus Generation for an Electronic Community System.
ERIC Educational Resources Information Center
Chen, Hsinchun; And Others
1995-01-01
This research reports an algorithmic approach to the automatic generation of thesauri for electronic community systems. The techniques used include term filtering, automatic indexing, and cluster analysis. The Worm Community System, used by molecular biologists studying the nematode worm C. elegans, was used as the testbed for this research.…
Weintraub, Ari Y; Deutsch, Ellen S; Hales, Roberta L; Buchanan, Newton A; Rock, Whitney L; Rehman, Mohamed A
2017-06-01
Learning to use a new electronic anesthesia information management system can be challenging. Documenting anesthetic events, medication administration, and airway management in an unfamiliar system while simultaneously caring for a patient with the vigilance required for safe anesthesia can be distracting and risky. This technical report describes a vendor-agnostic approach to training using a high-technology manikin in a simulated clinical scenario. Training was feasible and valued by participants but required a combination of electronic and manual components. Further exploration may reveal simulated patient care training that provides the greatest benefit to participants as well as feedback to inform electronic health record improvements.
Differences between Subjective Balanced Occlusion and Measurements Reported With T-Scan III
Lila-Krasniqi, Zana; Shala, Kujtim; Krasniqi, Teuta Pustina; Bicaj, Teuta; Ahmedi, Enis; Dula, Linda; Dragusha, Arlinda Tmava; Guguvcevski, Ljuben
2017-01-01
BACKGROUND: The aetiology of Temporomandibular disorder is multifactorial, and numerous studies have addressed that occlusion may be of great importance in the pathogenesis of Temporomandibular disorder. AIM: The aim of this study is to determine if any direct relationship exists between balanced occlusion and Temporomandibular disorder and to evaluate the differences between subjective balanced occlusion and measurements reported with T-scan III electronic system. MATERIAL AND METHODS: A total of 54 subjects were divided into three groups, selection based on anamnesis-responded to a Fonseca questionnaire and clinical measurements analysed with electronic system T-scan III. In the I study group were participants with fixed dentures with prosthetic ceramic restorations. In the II study group were symptomatic participants with TMD. In the third control group were healthy participants with full arch dentition that completed a subjective questionnaire that documented the absence of jaw pain, joint noise, locking and subjects without a history of TMD. The occlusal balance was reported subjectively through Fonseca questionnaire and compared with occlusion analysed with electronic system T-scan III. RESULTS: For attributive data were used percentage of the structure. Differences in P < 0.05 were considered significant. After distributing attributive data of occlusal balance subjectively reported and compared with measurements analysed with electronic system T-scan III were found significant difference P < 0.001 in all three groups. CONCLUSION: In our study, it was concluded that there were statistically significant differences of balanced occlusion in all three groups. Also it was concluded that subjective data are not exact with measurements reported with electronic device T-scan III. PMID:28932311
Rorie, David A; Flynn, Robert W V; Grieve, Kerr; Doney, Alexander; Mackenzie, Isla; MacDonald, Thomas M; Rogers, Amy
2017-09-01
Researchers in clinical and pharmacoepidemiology fields have adopted information technology (IT) and electronic data capture, but these remain underused despite the benefits. This review discusses electronic case report forms and electronic data capture, specifically within pharmacoepidemiology and clinical research. The review used PubMed and the Institute of Electrical and Electronic Engineers library. Search terms used were agreed by the authors and documented. PubMed is medical and health based, whereas Institute of Electrical and Electronic Engineers is technology based. The review focuses on electronic case report forms and electronic data capture, but briefly considers other relevant topics; consent, ethics and security. There were 1126 papers found using the search terms. Manual filtering and reviewing of abstracts further condensed this number to 136 relevant manuscripts. The papers were further categorized: 17 contained study data; 40 observational data; 27 anecdotal data; 47 covering methodology or design of systems; one case study; one literature review; two feasibility studies; and one cost analysis. Electronic case report forms, electronic data capture and IT in general are viewed with enthusiasm and are seen as a cost-effective means of improving research efficiency, educating participants and improving trial recruitment, provided concerns about how data will be protected from misuse can be addressed. Clear operational guidelines and best practises are key for healthcare providers, and researchers adopting IT, and further work is needed on improving integration of new technologies with current systems. A robust method of evaluation for technical innovation is required. © 2017 The Authors. British Journal of Clinical Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.
Flynn, Robert W. V.; Grieve, Kerr; Doney, Alexander; Mackenzie, Isla; MacDonald, Thomas M.; Rogers, Amy
2017-01-01
Aims Researchers in clinical and pharmacoepidemiology fields have adopted information technology (IT) and electronic data capture, but these remain underused despite the benefits. This review discusses electronic case report forms and electronic data capture, specifically within pharmacoepidemiology and clinical research. Methods The review used PubMed and the Institute of Electrical and Electronic Engineers library. Search terms used were agreed by the authors and documented. PubMed is medical and health based, whereas Institute of Electrical and Electronic Engineers is technology based. The review focuses on electronic case report forms and electronic data capture, but briefly considers other relevant topics; consent, ethics and security. Results There were 1126 papers found using the search terms. Manual filtering and reviewing of abstracts further condensed this number to 136 relevant manuscripts. The papers were further categorized: 17 contained study data; 40 observational data; 27 anecdotal data; 47 covering methodology or design of systems; one case study; one literature review; two feasibility studies; and one cost analysis. Conclusion Electronic case report forms, electronic data capture and IT in general are viewed with enthusiasm and are seen as a cost‐effective means of improving research efficiency, educating participants and improving trial recruitment, provided concerns about how data will be protected from misuse can be addressed. Clear operational guidelines and best practises are key for healthcare providers, and researchers adopting IT, and further work is needed on improving integration of new technologies with current systems. A robust method of evaluation for technical innovation is required. PMID:28276585
Sujansky, Walter V; Overhage, J Marc; Chang, Sophia; Frohlich, Jonah; Faus, Samuel A
2009-01-01
Electronic laboratory interfaces can significantly increase the value of ambulatory electronic health record (EHR) systems by providing laboratory result data automatically and in a computable form. However, many ambulatory EHRs cannot implement electronic laboratory interfaces despite the existence of messaging standards, such as Health Level 7, version 2 (HL7). Among several barriers to implementing laboratory interfaces is the extensive optionality within the HL7 message standard. This paper describes the rationale for and development of an HL7 implementation guide that seeks to eliminate most of the optionality inherent in HL7, but retain the information content required for reporting outpatient laboratory results. A work group of heterogeneous stakeholders developed the implementation guide based on a set of design principles that emphasized parsimony, practical requirements, and near-term adoption. The resulting implementation guide contains 93% fewer optional data elements than HL7. This guide was successfully implemented by 15 organizations during an initial testing phase and has been approved by the HL7 standards body as an implementation guide for outpatient laboratory reporting. Further testing is required to determine whether widespread adoption of the implementation guide by laboratories and EHR systems can facilitate the implementation of electronic laboratory interfaces.
Electronic Self-report Assessment--Cancer (ESRA-C): Working towards an integrated survey system.
Karras, Bryant T; Wolpin, Seth; Lober, William B; Bush, Nigel; Fann, Jesse R; Berry, Donna L
2006-01-01
The Clinical Informatics Research Group and Biobehavioral Nursing and Health Systems at the University of Washington are working with interdisciplinary teams to improve patient care and tracking of patient-reported symptoms and outcomes by creating an extensible web-based survey and intervention platform. The findings and cumulative experience from these processes have led to incremental improvements and variations in each new implementation of the platform. This paper presents progress in the first year of a three-year NIH study entitled Electronic Self Report Assessment--Cancer (ESRA-C). The project's goals are to enhance and evaluate the web-based computerized patient self-reporting and assessment system at the Seattle Cancer Care Alliance. Preliminary work and lessons learned in the modification of the platform and enhancements to the system will be described.
Electronic toll collection interoperability study in Brazil. Task 1 : data collection
DOT National Transportation Integrated Search
1998-05-01
The report, conducted by Parsons Bricknerhoff International, was funded by the U.S. Trade and Development Agency. The report examines the potential for developing electronic toll collection systems in Brazil. This is volume I and it is Task 1, the da...
Parl, Fritz F; O'Leary, Mandy F; Kaiser, Allen B; Paulett, John M; Statnikova, Kristina; Shultz, Edward K
2010-03-01
Current practices of reporting critical laboratory values make it challenging to measure and assess the timeliness of receipt by the treating physician as required by The Joint Commission's 2008 National Patient Safety Goals. A multidisciplinary team of laboratorians, clinicians, and information technology experts developed an electronic ALERTS system that reports critical values via the laboratory and hospital information systems to alphanumeric pagers of clinicians and ensures failsafe notification, instant documentation, automatic tracking, escalation, and reporting of critical value alerts. A method for automated acknowledgment of message receipt was incorporated into the system design. The ALERTS system has been applied to inpatients and eliminated approximately 9000 phone calls a year made by medical technologists. Although a small number of phone calls were still made as a result of pages not acknowledged by clinicians within 10 min, they were made by telephone operators, who either contacted the same physician who was initially paged by the automated system or identified and contacted alternate physicians or the patient's nurse. Overall, documentation of physician acknowledgment of receipt in the electronic medical record increased to 95% of critical values over 9 months, while the median time decreased to <3 min. We improved laboratory efficiency and physician communication by developing an electronic system for reporting of critical values that is in compliance with The Joint Commission's goals.
NASA Tech Briefs, May 1998. Volume 22, No. 5
NASA Technical Reports Server (NTRS)
1998-01-01
Topics include: special coverage on advanced composites, plastics and metals, electronic components and circuits, electronic systems, physical sciences, computer software, mechanics, machinery/automation, manufacturing/fabrication book and reports, and a special section of Electronics Tech Briefs.
Gluskin, Rebecca Tave; Mavinkurve, Maushumi; Varma, Jay K
2014-03-01
For nearly a decade, interest groups, from politicians to economists to physicians, have touted digitization of the nation's health information. One frequently mentioned benefit is the transmission of information electronically from laboratories to public health personnel, allowing them to rapidly analyze and act on these data. Switching from paper to electronic laboratory reports (ELRs) was thought to solve many public health surveillance issues, including workload, accuracy, and timeliness. However, barriers remain for both laboratories and public health agencies to realize the full benefits of ELRs. The New York City experience highlights several successes and challenges of electronic reporting and is supported by peer-reviewed literature. Lessons learned from ELR systems will benefit efforts to standardize electronic medical records reporting to health departments.
Architecture of a prehospital emergency patient care report system (PEPRS).
Majeed, Raphael W; Stöhr, Mark R; Röhrig, Rainer
2013-01-01
In recent years, prehospital emergency care adapted to the technology shift towards tablet computers and mobile computing. In particular, electronic patient care report (e-PCR) systems gained considerable attention and adoption in prehospital emergency medicine [1]. On the other hand, hospital information systems are already widely adopted. Yet, there is no universal solution for integrating prehospital emergency reports into electronic medical records of hospital information systems. Previous projects either relied on proprietary viewing workstations or examined and transferred only data for specific diseases (e.g. stroke patients[2]). Using requirements engineering and a three step software engineering approach, this project presents a generic architecture for integrating prehospital emergency care reports into hospital information systems. Aim of this project is to describe a generic architecture which can be used to implement data transfer and integration of pre hospital emergency care reports to hospital information systems. In summary, the prototype was able to integrate data in a standardized manner. The devised methods can be used design generic software for prehospital to hospital data integration.
NASA Technical Reports Server (NTRS)
Ambur, Manjula Y.; Adams, David L.; Trinidad, P. Paul
1997-01-01
NASA Langley Technical Library has been involved in developing systems for full-text information delivery of NACA/NASA technical reports since 1991. This paper will describe the two prototypes it has developed and the present production system configuration. The prototype systems are a NACA CD-ROM of thirty-three classic paper NACA reports and a network-based Full-text Electronic Reports Documents System (FEDS) constructed from both paper and electronic formats of NACA and NASA reports. The production system is the DigiDoc System (DIGItal Documents) presently being developed based on the experiences gained from the two prototypes. DigiDoc configuration integrates the on-line catalog database World Wide Web interface and PDF technology to provide a powerful and flexible search and retrieval system. It describes in detail significant achievements and lessons learned in terms of data conversion, storage technologies, full-text searching and retrieval, and image databases. The conclusions from the experiences of digitization and full- text access and future plans for DigiDoc system implementation are discussed.
Evaluation of minimum drinking age laws using the national electronic injury surveillance system
DOT National Transportation Integrated Search
1982-01-01
The report analyzes driver injury data collected by the National Electronic Injury Surveillance System (NEISS) from October 1978 through December 1980. Nighttime driver injury rates in States with lower legal drinking age (18-19 years old) were compa...
ERIC Educational Resources Information Center
Losh, Charles
The Electronics Industries Foundation was awarded a project to develop national entry-level standards and a certification system. Ten specialties were included: automotive electronics, avionics, biomedical electronics, business machines, consumer products electronics, general electronics, industrial electronics, instrumentation, microcomputer, and…
Nurses' perceptions of the impact of electronic health records on work and patient outcomes.
Kossman, Susan P; Scheidenhelm, Sandra L
2008-01-01
This study addresses community hospital nurses' use of electronic health records and views of the impact of such records on job performance and patient outcomes. Questionnaire, interview, and observation data from 46 nurses in medical-surgical and intensive care units at two community hospitals were analyzed. Nurses preferred electronic health records to paper charts and were comfortable with technology. They reported use of electronic health records enhanced nursing work through increased information access, improved organization and efficiency, and helpful alert screens. They thought use of the records hindered nursing work through impaired critical thinking, decreased interdisciplinary communication, and a high demand on work time (73% reported spending at least half their shift using the records). They thought use of electronic health records enabled them to provide safer care but decreased the quality of care. Administrative implications include involving bedside nurses in system choice, streamlining processes, developing guidelines for consistent documentation quality and location, increasing system speed, choosing hardware that encourages bedside use, and improving system information technology support.
Central Federal Lands Division data collection packages : final report.
DOT National Transportation Integrated Search
2011-03-31
The purpose of this research study was to develop a proof of concept, prototype electronic data-collection and reporting system to facilitate the completion of Emergency Relief for Federally Owned (ERFO) Roads Damage Site Reports (DSR). The system wo...
NASA Electronic Publishing System: Cost/benefit Methodology
NASA Technical Reports Server (NTRS)
Tuey, Richard C.
1994-01-01
The NASA Scientific and Technical Information Office was assigned the responsibility to examine the benefits of the utilization of electronic printing and duplicating systems throughout NASA Installations and Headquarters. The subject of this report is the documentation of the methodology used in justifying the acquisition of the most cost beneficial solution for the printing and duplicating requirements of a duplicating facility that is contemplating the acquisition of an electronic printing and duplicating system. Four alternatives are presented with each alternative costed out with its associated benefits. The methodology goes a step further than just a cost benefit analysis through its comparison of risks associated with each alternative, sensitivity to number of impressions and productivity gains on the selected alternative and finally the return on investment for the selected alternative. The report can be used in conjunction with the two earlier reports, NASA-TM-106242 and TM-106510 in guiding others in determining the cost effective duplicating alternative.
Hata, S; Miyazaki, S; Gondo, T; Kawamoto, K; Horii, N; Sato, K; Furukawa, H; Kudo, H; Miyazaki, H; Murayama, M
2017-04-01
This paper reports the preliminary results of a new in-situ three-dimensional (3D) imaging system for observing plastic deformation behavior in a transmission electron microscope (TEM) as a directly relevant development of the recently reported straining-and-tomography holder [Sato K et al. (2015) Development of a novel straining holder for transmission electron microscopy compatible with single tilt-axis electron tomography. Microsc. 64: 369-375]. We designed an integrated system using the holder and newly developed straining and image-acquisition software and then developed an experimental procedure for in-situ straining and time-resolved electron tomography (ET) data acquisition. The software for image acquisition and 3D visualization was developed based on the commercially available ET software TEMographyTM. We achieved time-resolved 3D visualization of nanometer-scale plastic deformation behavior in a Pb-Sn alloy sample, thus demonstrating the capability of this system for potential applications in materials science. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Southwest electronic one-stop shopping, motor carrier test report
DOT National Transportation Integrated Search
1997-12-22
The Electronic One-Stop System (EOSS) used in this credential test was designed to replace current normal credentialling procedures with a personal computer-based electronic method that allows users to prepare, apply for, and obtain certain types of ...
Southwest electronic one-stop shopping, state agency test report
DOT National Transportation Integrated Search
1997-12-22
The Electronic One-Stop System (EOSS) used in this credential test was designed to replace current normal credentialling procedures with a personal computer-based electronic method that allows users to prepare, apply for, and obtain certain types of ...
DOT National Transportation Integrated Search
1995-05-01
This report describes the research program being conducted at the Volpe National Transportation Systems Center on the development of electronic aeronautical charts. The design of electronic aeronautical navigation charts raises many interrelated huma...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2012 CFR
2012-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2011 CFR
2011-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2014 CFR
2014-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2013 CFR
2013-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2010 CFR
2010-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
NASA Tech Briefs, November 1997. Volume 21, No. 11
NASA Technical Reports Server (NTRS)
1997-01-01
Topics covered include: Test and Measurement; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Software; Mechanics; Machinery/Automation; Books and Reports..
Jensen, Roxanne E; Rothrock, Nan E; DeWitt, Esi M; Spiegel, Brennan; Tucker, Carole A; Crane, Heidi M; Forrest, Christopher B; Patrick, Donald L; Fredericksen, Rob; Shulman, Lisa M; Cella, David; Crane, Paul K
2015-02-01
Patient-reported outcomes (PROs) are gaining recognition as key measures for improving the quality of patient care in clinical care settings. Three factors have made the implementation of PROs in clinical care more feasible: increased use of modern measurement methods in PRO design and validation, rapid progression of technology (eg, touchscreen tablets, Internet accessibility, and electronic health records), and greater demand for measurement and monitoring of PROs by regulators, payers, accreditors, and professional organizations. As electronic PRO collection and reporting capabilities have improved, the challenges of collecting PRO data have changed. To update information on PRO adoption considerations in clinical care, highlighting electronic and technical advances with respect to measure selection, clinical workflow, data infrastructure, and outcomes reporting. Five practical case studies across diverse health care settings and patient populations are used to explore how implementation barriers were addressed to promote the successful integration of PRO collection into the clinical workflow. The case studies address selecting and reporting of relevant content, workflow integration, previsit screening, effective evaluation, and electronic health record integration. These case studies exemplify elements of well-designed electronic systems, including response automation, tailoring of item selection and reporting algorithms, flexibility of collection location, and integration with patient health care data elements. They also highlight emerging logistical barriers in this area, such as the need for specialized technological and methodological expertise, and design limitations of current electronic data capture systems.
Tweya, Hannock; Feldacker, Caryl; Ben-Smith, Anne; Harries, Anthony D; Komatsu, Ryuichi; Jahn, Andreas; Phiri, Sam; Tassie, Jean-Michel
2012-07-20
Routine monitoring of patients on antiretroviral therapy (ART) is crucial for measuring program success and accurate drug forecasting. However, compiling data from patient registers to measure retention in ART is labour-intensive. To address this challenge, we conducted a pilot study in Malawi to assess whether patient ART retention could be determined using pharmacy records as compared to estimates of retention based on standardized paper- or electronic based cohort reports. Twelve ART facilities were included in the study: six used paper-based registers and six used electronic data systems. One ART facility implemented an electronic data system in quarter three and was included as a paper-based system facility in quarter two only. Routine patient retention cohort reports, paper or electronic, were collected from facilities for both quarter two [April-June] and quarter three [July-September], 2010. Pharmacy stock data were also collected from the 12 ART facilities over the same period. Numbers of ART continuation bottles recorded on pharmacy stock cards at the beginning and end of each quarter were documented. These pharmacy data were used to calculate the total bottles dispensed to patients in each quarter with intent to estimate the number of patients retained on ART. Information for time required to determine ART retention was gathered through interviews with clinicians tasked with compiling the data. Among ART clinics with paper-based systems, three of six facilities in quarter two and four of five facilities in quarter three had similar numbers of patients retained on ART comparing cohort reports to pharmacy stock records. In ART clinics with electronic systems, five of six facilities in quarter two and five of seven facilities in quarter three had similar numbers of patients retained on ART when comparing retention numbers from electronically generated cohort reports to pharmacy stock records. Among paper-based facilities, an average of 13 4 hours was needed to calculate patient retention for cohort reporting using patient registers as compared to 2.25 hours using pharmacy stock cards. The numbers of patients retained on ART as estimated using pharmacy stock records were largely similar to estimates based on either paper registers or electronic data system. Furthermore, less time and staff effort was needed to estimate ART patient retention using pharmacy stock records versus paper-based registers. Reinforcing ARV stock management may improve the precision of estimates.
Report details eRx challenges and provides suggestions for increased adoption.
2004-07-01
A new report by the eHealth Initiative (http://www.ehealthinitiative.org) looks at electronic prescribing, or "eRx," and discusses its benefits, challenges to adoption, and movements toward adoption. Released in April 2004, the 154-page report--Electronic Prescribing: Toward Maximum Value and Rapid Adoption--also highlights recommendations for the optimal design of an eRx system.
Giovanni, Mazza G; Shenvi, Rohit; Battles, Marcie; Orthner, Helmuth F
2008-11-06
The eMonitor is a component of the ePatient system; a prototype system used by emergency medical services (EMS) personnel in the field to record and transmits electronic patient care report (ePCR) information interactively. The eMonitor component allows each Mobile Data Terminal (MDT) on an unreliable Cisco MobileIP wireless network to securely send and received XML messages used to update patient information to and from the MDT before, during and after the transport of a patient.
DOT National Transportation Integrated Search
1998-05-01
This report, conducted by Parsons Bricknerhoff International, was funded by the U.S. Trade and Development Agency. The report examines the potential for developing electronic toll collection systems in Brazil. This is Volume II and it contains "Task ...
U.S. Central Command Headquarters’ Use of the Government Purchase Card
2011-01-25
required the coordinator to document training sessions. During our review, the squadron was developing a new electronic system to support the...approving officials and cardholders. 2. Establish a plan to ensure that the new electronic Government Purchase Card Tracking system is completed...tickets,” invoices, shipping/packing documents or receiving reports, or electronic purchase confirmations are acceptable) for each purchase and other
Electronic recording and reporting system for tuberculosis in China: experience and opportunities
Huang, Fei; Cheng, ShiMing; Du, Xin; Chen, Wei; Scano, Fabio; Falzon, Dennis; Wang, Lixia
2014-01-01
Tuberculosis (TB) surveillance in China is organized through a nationwide network of about 3200 hospitals and health facilities. In 2005, an electronic Tuberculosis Information Management System (TBIMS) started to be phased in to replace paper recording. The TBIMS collects key information on TB cases notified in TB care facilities, and exchanges real-time data with the Infectious Disease Reporting System, which covers the country’s 37 notifiable diseases. The system is accessible to authorized users at every level of the TB network through a password-protected website. By 2009 the TBIMS achieved nationwide coverage. Completeness of data on patient bacteriological end points improved remarkably over time. Data on about a million active TB cases, including drug-resistant TB, are included each year. The sheer scale of the data handling and the intricate functions that the China TBIMS performs makes it stand apart from the electronic information systems for TB adopted in other countries. PMID:24326537
Fermi arcs vs. fermi pockets in electron-doped perovskite iridates
He, Junfeng; Hafiz, H.; Mion, Thomas R.; ...
2015-02-23
We report on an angle resolved photoemission (ARPES) study of bulk electron-doped perovskite iridate, (Sr 1-xLa x)₃Ir₂O₇. Fermi surface pockets are observed with a total electron count in keeping with that expected from La substitution. Depending on the energy and polarization of the incident photons, these pockets show up in the form of disconnected “Fermi arcs”, reminiscent of those reported recently in surface electron-doped Sr₂IrO₄. Our observed spectral variation is consistent with the coexistence of an electronic supermodulation with structural distortion in the system.
Mega-electron-volt ultrafast electron diffraction at SLAC National Accelerator Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weathersby, S. P.; Brown, G.; Chase, T. F.
Ultrafast electron probes are powerful tools, complementary to x-ray free-electron lasers, used to study structural dynamics in material, chemical, and biological sciences. High brightness, relativistic electron beams with femtosecond pulse duration can resolve details of the dynamic processes on atomic time and length scales. SLAC National Accelerator Laboratory recently launched the Ultrafast Electron Diffraction (UED) and microscopy Initiative aiming at developing the next generation ultrafast electron scattering instruments. As the first stage of the Initiative, a mega-electron-volt (MeV) UED system has been constructed and commissioned to serve ultrafast science experiments and instrumentation development. The system operates at 120-Hz repetition ratemore » with outstanding performance. In this paper, we report on the SLAC MeV UED system and its performance, including the reciprocal space resolution, temporal resolution, and machine stability.« less
Mega-electron-volt ultrafast electron diffraction at SLAC National Accelerator Laboratory.
Weathersby, S P; Brown, G; Centurion, M; Chase, T F; Coffee, R; Corbett, J; Eichner, J P; Frisch, J C; Fry, A R; Gühr, M; Hartmann, N; Hast, C; Hettel, R; Jobe, R K; Jongewaard, E N; Lewandowski, J R; Li, R K; Lindenberg, A M; Makasyuk, I; May, J E; McCormick, D; Nguyen, M N; Reid, A H; Shen, X; Sokolowski-Tinten, K; Vecchione, T; Vetter, S L; Wu, J; Yang, J; Dürr, H A; Wang, X J
2015-07-01
Ultrafast electron probes are powerful tools, complementary to x-ray free-electron lasers, used to study structural dynamics in material, chemical, and biological sciences. High brightness, relativistic electron beams with femtosecond pulse duration can resolve details of the dynamic processes on atomic time and length scales. SLAC National Accelerator Laboratory recently launched the Ultrafast Electron Diffraction (UED) and microscopy Initiative aiming at developing the next generation ultrafast electron scattering instruments. As the first stage of the Initiative, a mega-electron-volt (MeV) UED system has been constructed and commissioned to serve ultrafast science experiments and instrumentation development. The system operates at 120-Hz repetition rate with outstanding performance. In this paper, we report on the SLAC MeV UED system and its performance, including the reciprocal space resolution, temporal resolution, and machine stability.
NASA Tech Briefs, July 1999. Volume 23, No. 7
NASA Technical Reports Server (NTRS)
1999-01-01
Topics: Test and Measurement; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Software; Mechanics; Machinery/Automation; Bio-Medical; Books and Reports; Semiconductors/ICs.
NASA Tech Briefs, January 1998. Volume 22, No. 1
NASA Technical Reports Server (NTRS)
1998-01-01
Topics: Sensors/Data Acquisition; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Software; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Life Sciences; Books and Reports.
NASA Tech Briefs, January 1997. Volume 21, No. 1
NASA Technical Reports Server (NTRS)
1997-01-01
Topics: Sensors; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Books and Reports.
Electronic Equipment Maintenance Training (EEMT) System: System Definition Phase.
ERIC Educational Resources Information Center
Pine, S. M.; And Others
The second in a series of four reports on the Electronic Equipment Maintenance Training (EEMT) project, this document summarizes the system definition phase of the EEMT program. The purpose of this phase of the project was to define a comprehensive set of functions and training requirements that the EEMT must satisfy within the training mission of…
Natural occupation numbers in two-electron quantum rings.
Tognetti, Vincent; Loos, Pierre-François
2016-02-07
Natural orbitals (NOs) are central constituents for evaluating correlation energies through efficient approximations. Here, we report the closed-form expression of the NOs of two-electron quantum rings, which are prototypical finite-extension systems and new starting points for the development of exchange-correlation functionals in density functional theory. We also show that the natural occupation numbers for these two-electron paradigms are in general non-vanishing and follow the same power law decay as atomic and molecular two-electron systems.
Natural occupation numbers in two-electron quantum rings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tognetti, Vincent, E-mail: vincent.tognetti@univ-rouen.fr; Loos, Pierre-François
2016-02-07
Natural orbitals (NOs) are central constituents for evaluating correlation energies through efficient approximations. Here, we report the closed-form expression of the NOs of two-electron quantum rings, which are prototypical finite-extension systems and new starting points for the development of exchange-correlation functionals in density functional theory. We also show that the natural occupation numbers for these two-electron paradigms are in general non-vanishing and follow the same power law decay as atomic and molecular two-electron systems.
Identifying Effectiveness Criteria for Internet Payment Systems.
ERIC Educational Resources Information Center
Shon, Tae-Hwan; Swatman, Paula M. C.
1998-01-01
Examines Internet payment systems (IPS): third-party, card, secure Web server, electronic token, financial electronic data interchange (EDI), and micropayment based. Reports the results of a Delphi survey of experts identifying and classifying IPS effectiveness criteria and classifying types of IPS providers. Includes the survey invitation letter…
Lim, Eugene Y; Lee, Chiang; Cai, Weidong; Feng, Dagan; Fulham, Michael
2007-01-01
Medical practice is characterized by a high degree of heterogeneity in collaborative and cooperative patient care. Fast and effective communication between medical practitioners can improve patient care. In medical imaging, the fast delivery of medical reports to referring medical practitioners is a major component of cooperative patient care. Recently, mobile phones have been actively deployed in telemedicine applications. The mobile phone is an ideal medium to achieve faster delivery of reports to the referring medical practitioners. In this study, we developed an electronic medical report delivery system from a medical imaging department to the mobile phones of the referring doctors. The system extracts a text summary of medical report and a screen capture of diagnostic medical image in JPEG format, which are transmitted to 3G GSM mobile phones.
Adnan, Mehnaz; Peterkin, Donald; Lopez, Liza; Mackereth, Graham
2017-02-01
Electronic reporting of Influenza-like illness (eILI) from primary care was implemented and evaluated in three general medical practices in New Zealand during May to September 2015. To measure the uptake of eILI and to identify the system's strength and limitations. Analysis of transactional data from the eILI system; comparative study of influenza-like illness cases reported using manual methods and eILI; questionnaire administered to clinical and operational stakeholders. Over the study period 66% of total ILI cases were reported using eILI. Reporting timeliness improved significantly compared to manual reporting with an average of 24 minutes from submission by the clinician to processing in the national database. Users found the system to be user-friendly. eILI assists clinicians to report ILI cases to public health authorities within a stipulated time period and is associated with faster, more reliable and improved information transfer.
78 FR 8536 - Privacy Act of 1974; Report of New System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-06
... operating system. Any electronic or hard copies of financial- related records containing PII at CMS and... SYSTEM: None. Dated: January 10, 2013. Michelle Snyder, Deputy Chief Operating Officer, Centers for... 1974; Report of New System of Records AGENCY: Department of Health and Human Services (HHS), Centers...
Electronic prescribing in pediatrics: toward safer and more effective medication management.
Johnson, Kevin B; Lehmann, Christoph U
2013-04-01
This technical report discusses recent advances in electronic prescribing (e-prescribing) systems, including the evidence base supporting their limitations and potential benefits. Specifically, this report acknowledges that there are limited but positive pediatric data supporting the role of e-prescribing in mitigating medication errors, improving communication with dispensing pharmacists, and improving medication adherence. On the basis of these data and on the basis of federal statutes that provide incentives for the use of e-prescribing systems, the American Academy of Pediatrics recommends the adoption of e-prescribing systems with pediatric functionality. This report supports the accompanying policy statement from the American Academy of Pediatrics recommending the adoption of e-prescribing by pediatric health care providers.
NASA Tech Briefs, December 1997. Volume 21, No. 12
NASA Technical Reports Server (NTRS)
1997-01-01
Topics: Design and Analysis Software; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Software; Mechanics; Manufacturing/Fabrication; Mathematics and Information Sciences; Books and Reports.
32 CFR 989.35 - Reporting requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... documents electronically. Public review comments should be required in writing, rather than by electronic... measures will be tracked at bases and MAJCOMs through an appropriate environmental management system. (b...
32 CFR 989.35 - Reporting requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... documents electronically. Public review comments should be required in writing, rather than by electronic... measures will be tracked at bases and MAJCOMs through an appropriate environmental management system. (b...
32 CFR 989.35 - Reporting requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... documents electronically. Public review comments should be required in writing, rather than by electronic... measures will be tracked at bases and MAJCOMs through an appropriate environmental management system. (b...
32 CFR 989.35 - Reporting requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... documents electronically. Public review comments should be required in writing, rather than by electronic... measures will be tracked at bases and MAJCOMs through an appropriate environmental management system. (b...
32 CFR 989.35 - Reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... documents electronically. Public review comments should be required in writing, rather than by electronic... measures will be tracked at bases and MAJCOMs through an appropriate environmental management system. (b...
NASA Tech Briefs, September 1994. Volume 18, No. 9
NASA Technical Reports Server (NTRS)
1994-01-01
Topics: Sensors; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences; Books and Reports.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Electronics Manufacturinglg I Table I-17 to Subpart I of Part 98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Electronics... for Electronics Manufacturinglg For each stack system for which you use the “stack test method” to...
NxStage dialysis system-associated thrombocytopenia: a report of two cases.
Sekkarie, Mohamed; Waldron, Michelle; Reynolds, Texas
2016-01-01
Thrombocytopenia in hemodialysis patients has recently been reported to be commonly caused by electron-beam sterilization of dialysis filters. We report the occurrence of thrombocytopenia in the first two patients of a newly established home hemodialysis program. The 2 patients switched from conventional hemodialysis using polysulfone electron-beam sterilized dialyzers to a NxStage system, which uses gamma sterilized polyehersulfone dialyzers incorporated into a drop-in cartridge. The thrombocytopenia resolved after return to conventional dialysis in both patients and recurred upon rechallenge in the patient who opted to retry NxStage. This is the first report of thrombocytopenia with the NxStage system according to the authorsâ knowledge. Dialysis-associated thrombocytopenia pathophysiology and clinical significance are not well understood and warrant additional investigations.
LASER Tech Briefs, Winter 1994. Volume 2, No. 1
NASA Technical Reports Server (NTRS)
Schnirring, Bill (Editor)
1994-01-01
Topics include: Electronic Components and Circuits. Electronic Systems, Physical Sciences, Materials, Computer Programs, Mechanics, Machinery, Fabrication Technology, Mathematics and Information Sciences, Life Sciences, and Books and reports
NASA Tech Briefs, September 2000. Volume 24, No. 9
NASA Technical Reports Server (NTRS)
2000-01-01
Topics include: Sensors; Test and Measurement; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Bio-Medical; semiconductors/ICs; Books and Reports.
NASA Tech Briefs, December 1994. Volume 18, No. 12
NASA Technical Reports Server (NTRS)
1994-01-01
Topics: Test and Measurement; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, January 1995. Volume 19, No. 1
NASA Technical Reports Server (NTRS)
1995-01-01
Topics include: Sensors; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, June 1996. Volume 20, No. 6
NASA Technical Reports Server (NTRS)
1996-01-01
Topics: New Computer Hardware; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences;Books and Reports.
ERIC Educational Resources Information Center
Rigney, J. W.; And Others
This report describes the Generalized Maintenance Trainer-Simulator (GMTS), an instructional system designed to give electronics students intensive troubleshooting practice in a simulated hands-on training environment, and reports on a field evaluation of the GMTS applied to systems level troubleshooting in radio communications. The GMTS can be…
Asynchronous automated electronic laboratory result notifications: a systematic review.
Slovis, Benjamin H; Nahass, Thomas A; Salmasian, Hojjat; Kuperman, Gilad; Vawdrey, David K
2017-11-01
To systematically review the literature pertaining to asynchronous automated electronic notifications of laboratory results to clinicians. PubMed, Web of Science, and the Cochrane Collaboration were queried for studies pertaining to automated electronic notifications of laboratory results. A title review was performed on the primary results, with a further abstract review and full review to produce the final set of included articles. The full review included 34 articles, representing 19 institutions. Of these, 19 reported implementation and design of systems, 11 reported quasi-experimental studies, 3 reported a randomized controlled trial, and 1 was a meta-analysis. Twenty-seven articles included alerts of critical results, while 5 focused on urgent notifications and 2 on elective notifications. There was considerable variability in clinical setting, system implementation, and results presented. Several asynchronous automated electronic notification systems for laboratory results have been evaluated, most from >10 years ago. Further research on the effect of notifications on clinicians as well as the use of modern electronic health records and new methods of notification is warranted to determine their effects on workflow and clinical outcomes. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Factors Affecting Educational Innovation with in Class Electronic Response Systems
ERIC Educational Resources Information Center
Freeman, Mark; Bell, Amani; Comerton-Forde, Carole; Pickering, Joanne; Blayney, Paul
2007-01-01
This paper reports the use of Rogers' diffusion of innovation perspective to understand the factors affecting educational innovation decisions, specifically in regard to in class electronic response systems. Despite decreasing costs and four decades of research showing strong student support, academic adoption is limited. Using data collected from…
ERIC Educational Resources Information Center
Ferguson, Douglas K.; And Others
1987-01-01
Describes five research projects that are setting up electronic information delivery systems to serve rural areas in the Pacific Northwest. The technologies being evaluated include simultaneous remote searching, facsimile transmissions, bit map image transmissions, and a combination of optical character recognition equipment and television…
Behavioral-Progress Monitoring Using the Electronic Daily Behavioral Report Card (e-DBRC) System
ERIC Educational Resources Information Center
Burke, Mack D.; Vannest, Kimberly J.
2008-01-01
In this article, the authors present an overview of a Web-based electronic system for behavioral-progress monitoring. Behavioral-progress monitoring is necessary to evaluate responsiveness to behavioral interventions, the effects of positive behavioral support, and the attainment of individualized education program goals and objectives. The…
Using Electronic Response Systems in Economics Classes
ERIC Educational Resources Information Center
Ghosh, Sucharita; Renna, Francesco
2009-01-01
College instructors and students participated in a pilot project at the University of Akron to enhance student learning through the use of a common teaching pedagogy, peer instruction. The teaching pedagogy was supported by the use of technology, an electronic personal response system, which recorded student responses. The authors report their…
Jang, Hye Jung; Choi, Young Deuk; Kim, Nam Hyun
2017-04-01
This paper describes an evaluation study on the effectiveness of developing an in-hospital medical device safety information reporting system for managing safety information, including adverse incident data related to medical devices, following the enactment of the Medical Device Act in Korea. Medical device safety information reports were analyzed for 190 cases that took place prior to the application of a medical device safety information reporting system and during a period when the reporting system was used. Also, questionnaires were used to measure the effectiveness of the medical device safety information reporting system. The analysis was based on the questionnaire responses of 15 reporters who submitted reports in both the pre- and post-reporting system periods. Sixty-two reports were submitted in paper form, but after the system was set up, this number more than doubled to 128 reports in electronic form. In terms of itemized reporting, a total of 45 items were reported. Before the system was used, 23 items had been reported, but this increased to 32 items after the system was put to use. All survey variables of satisfaction received a mean of over 3 points, while positive attitude , potential benefits , and positive benefits all exceeded 4 points, each receiving 4.20, 4.20, and 4.13, respectively. Among the variables, time-consuming and decision-making had the lowest mean values, each receiving 3.53. Satisfaction was found to be high for system quality and user satisfaction , but relatively low for time-consuming and decision-making . We were able to verify that effective reporting and monitoring of adverse incidents and the safety of medical devices can be implemented through the establishment of an in-hospital medical device safety information reporting system that can enhance patient safety and medical device risk management.
Kroon Van Diest, Ashley M; Ramsey, Rachelle; Aylward, Brandon; Kroner, John W; Sullivan, Stephanie M; Nause, Katie; Allen, Janelle R; Chamberlin, Leigh A; Slater, Shalonda; Hommel, Kevin; LeCates, Susan L; Kabbouche, Marielle A; O'Brien, Hope L; Kacperski, Joanne; Hershey, Andrew D; Powers, Scott W
2016-07-01
The purpose of this investigation was to examine treatment adherence to medication and lifestyle recommendations among pediatric migraine patients using electronic monitoring systems. Nonadherence to medical treatment is a significant public health concern, and can result in poorer treatment outcomes, decreased cost-effectiveness of medical care, and increased morbidity. No studies have systematically examined adherence to medication and lifestyle recommendations in adolescents with migraine outside of a clinical trial. Participants included 56 adolescents ages 11-17 who were presenting for clinical care. All were diagnosed with migraine with or without aura or chronic migraine and had at least 4 headache days per month. Medication adherence was objectively measured using electronic monitoring systems (Medication Event Monitoring Systems technology) and daily, prospective self-report via personal electronic devices. Adherence to lifestyle recommendations of regular exercise, eating, and fluid intake were also assessed using daily self-report on personal electronic devices. Electronic monitoring indicates that adolescents adhere to their medication 75% of the time, which was significantly higher than self-reported rates of medication adherence (64%). Use of electronic monitoring of medication detected rates of adherence that were significantly higher for participants taking once daily medication (85%) versus participants taking twice daily medication (59%). Average reported adherence to lifestyle recommendations of consistent noncaffeinated fluid intake (M = 5 cups per day) was below recommended levels of a minimum of 8 cups per day. Participants on average also reported skipping 1 meal per week despite recommendations of consistently eating three meals per day. Results suggest that intervention focused on adherence to preventive treatments (such as medication) and lifestyle recommendations may provide more optimal outcomes for children and adolescents with migraine and their families. Once daily dosing of medication may be preferred to twice daily medication for increased medication adherence among children and adolescents. © 2016 American Headache Society.
Automatic electronic fish tracking system
NASA Technical Reports Server (NTRS)
Osborne, P. W.; Hoffman, E.; Merriner, J. V.; Richards, C. E.; Lovelady, R. W.
1976-01-01
A newly developed electronic fish tracking system to automatically monitor the movements and migratory habits of fish is reported. The system is aimed particularly at studies of effects on fish life of industrial facilities which use rivers or lakes to dump their effluents. Location of fish is acquired by means of acoustic links from the fish to underwater Listening Stations, and by radio links which relay tracking information to a shore-based Data Base. Fish over 4 inches long may be tracked over a 5 x 5 mile area. The electronic fish tracking system provides the marine scientist with electronics which permit studies that were not practical in the past and which are cost-effective compared to manual methods.
Peterfreund, Robert A; Driscoll, William D; Walsh, John L; Subramanian, Aparna; Anupama, Shaji; Weaver, Melissa; Morris, Theresa; Arnholz, Sarah; Zheng, Hui; Pierce, Eric T; Spring, Stephen F
2011-05-01
Efforts to assure high-quality, safe, clinical care depend upon capturing information about near-miss and adverse outcome events. Inconsistent or unreliable information capture, especially for infrequent events, compromises attempts to analyze events in quantitative terms, understand their implications, and assess corrective efforts. To enhance reporting, we developed a secure, electronic, mandatory system for reporting quality assurance data linked to our electronic anesthesia record. We used the capabilities of our anesthesia information management system (AIMS) in conjunction with internally developed, secure, intranet-based, Web application software. The application is implemented with a backend allowing robust data storage, retrieval, data analysis, and reporting capabilities. We customized a feature within the AIMS software to create a hard stop in the documentation workflow before the end of anesthesia care time stamp for every case. The software forces the anesthesia provider to access the separate quality assurance data collection program, which provides a checklist for targeted clinical events and a free text option. After completing the event collection program, the software automatically returns the clinician to the AIMS to finalize the anesthesia record. The number of events captured by the departmental quality assurance office increased by 92% (95% confidence interval [CI] 60.4%-130%) after system implementation. The major contributor to this increase was the new electronic system. This increase has been sustained over the initial 12 full months after implementation. Under our reporting criteria, the overall rate of clinical events reported by any method was 471 events out of 55,382 cases or 0.85% (95% CI 0.78% to 0.93%). The new system collected 67% of these events (95% confidence interval 63%-71%). We demonstrate the implementation in an academic anesthesia department of a secure clinical event reporting system linked to an AIMS. The system enforces entry of quality assurance information (either no clinical event or notification of a clinical event). System implementation resulted in capturing nearly twice the number of events at a relatively steady case load. © 2011 International Anesthesia Research Society
iES - An Intelligent Electronic Sales Platform
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanton, V L; Korbe III, W; Gao, J G
Current e-commerce systems support online shopping based on electronic product catalogs. The major issues associated with catalog-based commerce systems are: difficulty in distinguishing one retailer from another, complex navigation with confusing links, and a lack of personalized service. This paper reports an intelligent solution to address these issues. Our solution will provide a more personalized sales experience through the use of a transaction-based knowledge model that includes both the rules used for reasoning as well as the corresponding actions. Based on this solution, we have developed an intelligent electronic sales platform that is supported by a framework which provides themore » desired personalization as well as extensibility and customization capabilities. This paper reports our design and development of this system and application examples.« less
An X Window system for statlab results reporting.
Barrows, R. C.; Allen, B.; Fink, D. J.
1993-01-01
We have developed a system that receives "stat" results encoded in Health Level Seven from the Laboratory Information System, prints a report in destination Intensive Care Units (ICUs), and captures the data for review in a custom spreadsheet format at color X-terminals located in ICUs. Available services include a reference nomogram plot of arterial blood gas data, printed summaries, automated access to the Clinical Information System and a Medline database, electronic mail, a simulated electronic calculator, and general news and information. Security mechanisms include an audit trail of user activities on the system. Noteworthy technical aspects and non-technical factors impacting success are discussed. Images Figure 2 Figure 3 PMID:8130490
NASA Tech Briefs, November 1998. Volume 22, No. 11
NASA Technical Reports Server (NTRS)
1998-01-01
Topics include: special coverage sections on test and measurement and sections on electronic components and circuits, electronic systems, software, materials, mechanics, machinery/automation, physical sciences, information sciences, book and reports, and special sections of Electronics Tech Briefs amd Rapid Product Development Tech Briefs.
NASA Tech Briefs, March 1996. Volume 20, No. 3
NASA Technical Reports Server (NTRS)
1996-01-01
Topics: Computer-Aided Design and Engineering; Electronic Components and Cicuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information; Books and Reports.
NASA Tech Briefs, September 1996. Volume 20, No. 9
NASA Technical Reports Server (NTRS)
1996-01-01
Topics: Data Acquisition and Analysis; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Books and Reports.
NASA Tech Briefs, August 1993. Volume 17, No. 8
NASA Technical Reports Server (NTRS)
1993-01-01
Topics include: Computer Graphics; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, September 1993. Volume 17, No. 9
NASA Technical Reports Server (NTRS)
1993-01-01
Topics include: Microelectronics; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, January 1994. Volume 18, No. 1
NASA Technical Reports Server (NTRS)
1994-01-01
Topics include: Communications Technology; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, November 1994. Volume 18, No. 11
NASA Technical Reports Server (NTRS)
1994-01-01
Topics: Advanced Manufacturing; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
Thermal Performance Benchmarking: Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moreno, Gilbert
2016-04-08
The goal for this project is to thoroughly characterize the performance of state-of-the-art (SOA) automotive power electronics and electric motor thermal management systems. Information obtained from these studies will be used to: Evaluate advantages and disadvantages of different thermal management strategies; establish baseline metrics for the thermal management systems; identify methods of improvement to advance the SOA; increase the publicly available information related to automotive traction-drive thermal management systems; help guide future electric drive technologies (EDT) research and development (R&D) efforts. The performance results combined with component efficiency and heat generation information obtained by Oak Ridge National Laboratory (ORNL) maymore » then be used to determine the operating temperatures for the EDT components under drive-cycle conditions. In FY15, the 2012 Nissan LEAF power electronics and electric motor thermal management systems were benchmarked. Testing of the 2014 Honda Accord Hybrid power electronics thermal management system started in FY15; however, due to time constraints it was not possible to include results for this system in this report. The focus of this project is to benchmark the thermal aspects of the systems. ORNL's benchmarking of electric and hybrid electric vehicle technology reports provide detailed descriptions of the electrical and packaging aspects of these automotive systems.« less
Oral, Bulent; Cullen, Regina M; Diaz, Danny L; Hod, Eldad A; Kratz, Alexander
2015-01-01
Downtimes of the laboratory information system (LIS) or its interface to the electronic medical record (EMR) disrupt the reporting of laboratory results. Traditionally, laboratories have relied on paper-based or phone-based reporting methods during these events. We developed a novel downtime procedure that combines advance placement of orders by clinicians for planned downtimes, the printing of laboratory results from instruments, and scanning of the instrument printouts into our EMR. The new procedure allows the analysis of samples from planned phlebotomies with no delays, even during LIS downtimes. It also enables the electronic reporting of all clinically urgent results during downtimes, including intensive care and emergency department samples, thereby largely avoiding paper- and phone-based communication of laboratory results. With the capabilities of EMRs and LISs rapidly evolving, information technology (IT) teams, laboratories, and clinicians need to collaborate closely, review their systems' capabilities, and design innovative ways to apply all available IT functions to optimize patient care during downtimes. Copyright© by the American Society for Clinical Pathology.
Kim, Min-Hye; Park, Chang-Han; Kim, Duk-In; Kim, Kyung-Mook; Kim, Hui-Kyu; Lim, Kyu-Hyoung; Song, Woo-Jung; Lee, Sang-Min; Kim, Sae-Hoon; Kwon, Hyouk-Soo; Park, Heung-Woo; Yoon, Chang-Jin; Cho, Sang-Heon; Min, Kyung-Up; Kim, You-Young; Chang, Yoon-Seok
2012-03-01
Contrast-media (CM) hypersensitivity is a well-known adverse drug reaction. Surveillance of adverse drug reactions usually depends on spontaneous reports. However, the rate of spontaneous reports is low. Recent progress in information technology enables the electronic search on signals of adverse drug reactions from electronic medical recording (EMR) systems. To analyze the incidence and clinical characteristics of CM hypersensitivity using an EMR-based surveillance system. The surveillance system used signals from standardized terms within the international classification of nursing practice terms that can indicate symptoms of CM hypersensitivity and from the order codes for procedures that used contrast media, antihistamine, and epinephrine. The search strategy was validated by allergists comparing the electronic search strategy versus manually reviewing medical charts over one month. The main study covered for one year period. Detection rate of the electronic search method was 0.9% (7/759), while that of the manual search method was 0.8% (6/759). EMR-based electronic search method was highly efficient: reduced the charts that needed to be reviewed by 96% (28/759). The sensitivity of electronic screening was 66.7%, specificity was 99.6%, and the negative predictive value was 99.7%. CM hypersensitivity reactions were noted in 266 among 12,483 cases (2.1%). Urticaria was the most frequent symptom (74.4%). CT was the most frequent procedure (3.6%) that induced CM hypersensitivity. A surveillance system using EMR may be a useful tool in the study of drug hypersensitivity epidemiology and may be used in an adverse drug reaction alarm system and as a clinical, decision making support system. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Fajardo, Geroncio C.; Posid, Joseph; Papagiotas, Stephen; Lowe, Luis
2015-01-01
There have been periodic electronic news media reports of potential bioterrorism-related incidents involving unknown substances (often referred to as “white powder”) since the 2001 intentional dissemination of Bacillus anthracis through the US Postal System. This study reviewed the number of unknown “white powder” incidents reported online by the electronic news media and compared them with unknown “white powder” incidents reported to the US Centers for Disease Control and Prevention (CDC) and the US Federal Bureau of Investigation (FBI) during a two-year period from June 1, 2009 and May 31, 2011. Results identified 297 electronic news media reports, 538 CDC reports, and 384 FBI reports of unknown “white powder.” This study showed different unknown “white powder” incidents captured by each of the three sources. However, the authors could not determine the public health implications of this discordance. PMID:25420771
Accuracy of parent-reported measles-containing vaccination status of children with measles.
Liu, G; Liao, Z; Xu, X; Liang, Y; Xiong, Y; Ni, J
2017-03-01
The validity of parent-reported measles-containing vaccination history in children with measles has not been assessed. This study evaluated the accuracy of parental recall of measles-containing vaccination histories in Shenzhen, China. A retrospective study was performed to compare the data from the electronic records with parental recall. The electronic records were regarded as accurate data about the children's measles-containing vaccination status. We collected data from the National Notifiable Diseases Surveillance System and the Immunization Program Information Management System in Shenzhen city, China. Between 2009 and 2014, there were 163 children with measles who had electronic vaccination records; the vaccination status of these cases was reported by the parents in the field epidemiological investigation. We validated parental recall with electronic records. The agreement between parental recall and electronic records was 78.7%. The kappa value was 0.57. The parent-reported measles-containing vaccination rate was higher than the electronic record (48.5% vs 41.7%, χ 2 = 53.64, P < 0.001). The true positive rate for parental recall was 82.4%, and the true negative rate was 75.8%. The positive predictive value was 70.9%, and the negative predictive value was 76.6%. In children with measles, parental recall slightly overestimated the measles vaccination rate, and the vaccination status recalled by parents was in moderate agreement with the electronic record. Copyright © 2016 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
CREM monitoring: a wireless RF application
NASA Astrophysics Data System (ADS)
Valencia, J. D.; Burghard, B. J.; Skorpik, J. R.; Silvers, K. L.; Schwartz, M. J.
2005-05-01
Recent security lapses within the Department of Energy laboratories prompted the establishment and implementation of additional procedures and training for operations involving classified removable electronic media (CREM) storage. In addition, the definition of CREM has been expanded and the number of CREM has increased significantly. Procedures now require that all CREM be inventoried and accounted for on a weekly basis. Weekly inventories consist of a physical comparison of each item against the reportable inventory listing. Securing and accounting for CREM is a continuous challenge for existing security systems. To address this challenge, an innovative framework, encompassing a suite of technologies, has been developed by Pacific Northwest National Laboratory (PNNL) to monitor, track, and locate CREM in safes, vaults, and storage areas. This Automated Removable Media Observation and Reporting (ARMOR)framework, described in this paper, is an extension of an existing PNNL program, SecureSafe. The key attributes of systems built around the ARMOR framework include improved accountability, reduced risk of human error, improved accuracy and timeliness of inventory data, and reduced costs. ARMOR solutions require each CREM to be tagged with a unique electronically readable ID code. Inventory data is collected from tagged CREM at regular intervals and upon detection of an access event. Automated inventory collection and report generation eliminates the need for hand-written inventory sheets and allows electronic transfer of the collected inventory data to a modern electronic reporting system. An electronic log of CREM access events is maintained, providing enhanced accountability for daily/weekly checks, routine audits, and follow-up investigations.
Evaluation of Electronic Registering Fareboxes
DOT National Transportation Integrated Search
1984-01-01
This report presents the findings of an evaluation of electronic registering fareboxes in use at four transit systems: Dallas Transit, Phoenix Transit, Southeastern Pennsylvania Transportation Authority, and the Metropolitan Suburban Bus Authority of...
NASA Tech Briefs, August 1997. Volume 21, No. 8
NASA Technical Reports Server (NTRS)
1997-01-01
Topics:Graphics and Simulation; Mechanical Components; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Software; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Books and Reports.
NASA Tech Briefs, June 1994. Volume 18, No. 6
NASA Technical Reports Server (NTRS)
1994-01-01
Topics covered include: Microelectronics; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, August 1994. Volume 18, No. 8
NASA Technical Reports Server (NTRS)
1994-01-01
Topics covered include: Computer Hardware; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, October 1996. Volume 20, No. 10
NASA Technical Reports Server (NTRS)
1996-01-01
Topics covered include: Sensors; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, June 1997. Volume 21, No. 6
NASA Technical Reports Server (NTRS)
1997-01-01
Topics include: Computer Hardware and Peripherals; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Books and Reports.
NASA Tech Briefs, November 1999. Volume 23, No. 11
NASA Technical Reports Server (NTRS)
1999-01-01
Topics covered include: Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Materials; Computer Programs; Mechanics; Machinery/Automation; Physical Sciences; Mathematics and Information Sciences; Books and Reports.
12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.
Code of Federal Regulations, 2010 CFR
2010-01-01
... consumer learns of the loss or theft; and extends the time periods for reporting unauthorized transfers or... 12 Banks and Banking 2 2010-01-01 2010-01-01 false Electronic fund transfer service provider not... GOVERNORS OF THE FEDERAL RESERVE SYSTEM ELECTRONIC FUND TRANSFERS (REGULATION E) § 205.14 Electronic fund...
12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.
Code of Federal Regulations, 2013 CFR
2013-01-01
... consumer learns of the loss or theft; and extends the time periods for reporting unauthorized transfers or... 12 Banks and Banking 2 2013-01-01 2013-01-01 false Electronic fund transfer service provider not... GOVERNORS OF THE FEDERAL RESERVE SYSTEM ELECTRONIC FUND TRANSFERS (REGULATION E) § 205.14 Electronic fund...
12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.
Code of Federal Regulations, 2014 CFR
2014-01-01
... consumer learns of the loss or theft; and extends the time periods for reporting unauthorized transfers or... 12 Banks and Banking 2 2014-01-01 2014-01-01 false Electronic fund transfer service provider not... GOVERNORS OF THE FEDERAL RESERVE SYSTEM ELECTRONIC FUND TRANSFERS (REGULATION E) § 205.14 Electronic fund...
12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.
Code of Federal Regulations, 2011 CFR
2011-01-01
... consumer learns of the loss or theft; and extends the time periods for reporting unauthorized transfers or... 12 Banks and Banking 2 2011-01-01 2011-01-01 false Electronic fund transfer service provider not... GOVERNORS OF THE FEDERAL RESERVE SYSTEM ELECTRONIC FUND TRANSFERS (REGULATION E) § 205.14 Electronic fund...
12 CFR 205.14 - Electronic fund transfer service provider not holding consumer's account.
Code of Federal Regulations, 2012 CFR
2012-01-01
... consumer learns of the loss or theft; and extends the time periods for reporting unauthorized transfers or... 12 Banks and Banking 2 2012-01-01 2012-01-01 false Electronic fund transfer service provider not... GOVERNORS OF THE FEDERAL RESERVE SYSTEM ELECTRONIC FUND TRANSFERS (REGULATION E) § 205.14 Electronic fund...
41 CFR 102-33.400 - How must we report to FAIRS?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION PERSONAL PROPERTY 33-MANAGEMENT OF... System (fairs) § 102-33.400 How must we report to FAIRS? You must report to FAIRS electronically through a secure Web interface to the FAIRS application on the Internet. For information on becoming a FAIRS...
Ashley, Laura; Jones, Helen; Forman, David; Newsham, Alex; Brown, Julia; Downing, Amy; Velikova, Galina; Wright, Penny
2011-10-26
Cancer survivors can face significant physical and psychosocial challenges; there is a need to identify and predict which survivors experience what sorts of difficulties. As highlighted in the UK National Cancer Survivorship Initiative, routine post-diagnostic collection of patient reported outcome measures (PROMs) is required; to be most informative, PROMs must be linked and analysed with patients' diagnostic and treatment information. We have designed and built a potentially cost-efficient UK-scalable electronic system for collecting PROMs via the internet, at regular post-diagnostic time-points, for linking these data with patients' clinical data in cancer registries, and for electronically managing the associated patient monitoring and communications; the electronic Patient-reported Outcomes from Cancer Survivors (ePOCS) system. This study aims to test the feasibility of the ePOCS system, by running it for 2 years in two Yorkshire NHS Trusts, and using the Northern and Yorkshire Cancer Registry and Information Service. Non-metastatic breast, colorectal and prostate cancer patients (largest survivor groups), within 6 months post-diagnosis, will be recruited from hospitals in the Yorkshire Cancer Network. Participants will be asked to complete PROMS, assessing a range of health-related quality-of-life outcomes, at three time-points up to 15 months post-diagnosis, and subsequently to provide opinion on the ePOCS system via a feedback questionnaire. Feasibility will be examined primarily in terms of patient recruitment and retention rates, the representativeness of participating patients, the quantity and quality of collected PROMs data, patients' feedback, the success and reliability of the underpinning informatics, and the system running costs. If sufficient data are generated during system testing, these will be analysed to assess the health-related quality-of-life outcomes reported by patients, and to explore if and how they relate to disease, treatment and/or individual differences characteristics. There is currently no system in the UK for collecting PROMs online and linking these with patients' clinical data in cancer registries. If feasible, ePOCS has potential to provide an affordable UK-scalable technical platform to facilitate and support longitudinal cohort research, and improve understanding of cancer survivors' experiences. Comprehensive understanding of survivorship difficulties is vital to inform the development and provision of supportive services and interventions.
Electronics Worksite Training Project. Final Report.
ERIC Educational Resources Information Center
Hata, David M.; Morris, Richard D.
The Oregon Electronics Worksite Training Program created a system for delivering vocational education and training to individuals employed within the electronics and manufacturing industry in the Portland metropolitan area. The approach selected by Portland Community College was to use interactive video instructional materials in a self-study,…
Cucina, Russell J; Bokser, Seth J; Carter, Jonathan T; McLaren, Kevin M; Blum, Michael S
2007-10-11
We report the development and implementation of an electronic inpatient physician documentation system using off-the-shelf components, rapidly and at low cost. Within 9 months of deployment, over half of physician notes were electronic, and within 20 months, paper physician notes were eliminated. Our results suggest institutions can prioritize conversion to inpatient electronic physician documentation without waiting for development of sophisticated software packages or large capital investments.
Sujansky, Walter; Wilson, Tom
2015-04-01
This report describes a grant-funded project to explore the use of DIRECT secure messaging for the electronic delivery of laboratory test results to outpatient physicians and electronic health record systems. The project seeks to leverage the inherent attributes of DIRECT secure messaging and electronic provider directories to overcome certain barriers to the delivery of lab test results in the outpatient setting. The described system enables laboratories that generate test results as HL7 messages to deliver these results as structured or unstructured documents attached to DIRECT secure messages. The system automatically analyzes generated HL7 messages and consults an electronic provider directory to determine the appropriate DIRECT address and delivery format for each indicated recipient. The system also enables lab results delivered to providers as structured attachments to be consumed by HL7 interface engines and incorporated into electronic health record systems. Lab results delivered as unstructured attachments may be printed or incorporated into patient records as PDF files. The system receives and logs acknowledgement messages to document the status of each transmitted lab result, and a graphical interface allows searching and review of this logged information. The described system is a fully implemented prototype that has been tested in a laboratory setting. Although this approach is promising, further work is required to pilot test the system in production settings with clinical laboratories and outpatient provider organizations. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Tech Briefs, February 1997. Volume 2, No. 2
NASA Technical Reports Server (NTRS)
1997-01-01
Topics include: Test and Measurement; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, November 1996. Volume 20, No. 11
NASA Technical Reports Server (NTRS)
1996-01-01
Topics covered: Video and Imaging; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, December 1996. Volume 20, No. 12
NASA Technical Reports Server (NTRS)
1996-01-01
Topics: Design and Analysis Software; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, May 1996. Volume 20, No. 5
NASA Technical Reports Server (NTRS)
1996-01-01
Topics include: Video and Imaging;Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, October 1993. Volume 17, No. 10
NASA Technical Reports Server (NTRS)
1993-01-01
Topics include: Sensors; esign and Engineering; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication technology; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, May 1994. Volume 18, No. 5
NASA Technical Reports Server (NTRS)
1994-01-01
Topics covered include: Robotics/Automation; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, February 1994. Volume 18, No. 2
NASA Technical Reports Server (NTRS)
1994-01-01
Topics covered include: Test and Measurement; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, July 1996. Volume 20, No. 7
NASA Technical Reports Server (NTRS)
1996-01-01
Topics covered include: Mechanical Components; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, January 2000. Volume 24, No. 1
NASA Technical Reports Server (NTRS)
2000-01-01
Topics include: Data Acquisition; Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Bio-Medical; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Information Sciences; Books and reports.
Diagnostic report acquisition unit for the Mayo/IBM PACS project
NASA Astrophysics Data System (ADS)
Brooks, Everett G.; Rothman, Melvyn L.
1991-07-01
The Mayo Clinic and IBM Rochester have jointly developed a picture archive and control system (PACS) for use with Mayo's MRI and Neuro-CT imaging modalities. One of the challenges of developing a useful PACS involves integrating the diagnostic reports with the electronic images so they can be displayed simultaneously. By the time a diagnostic report is generated for a particular case, its images have already been captured and archived by the PACS. To integrate the report with the images, the authors have developed an IBM Personal System/2 computer (PS/2) based diagnostic report acquisition unit (RAU). A typed copy of the report is transmitted via facsimile to the RAU where it is stacked electronically with other reports that have been sent previously but not yet processed. By processing these reports at the RAU, the information they contain is integrated with the image database and a copy of the report is archived electronically on an IBM Application System/400 computer (AS/400). When a user requests a set of images for viewing, the report is automatically integrated with the image data. By using a hot key, the user can toggle on/off the report on the display screen. This report describes process, hardware, and software employed to integrate the diagnostic report information into the PACS, including how the report images are captured, transmitted, and entered into the AS/400 database. Also described is how the archived reports and their associated medical images are located and merged for retrieval and display. The methods used to detect and process error conditions are also discussed.
Two-dimensional electron gas in monolayer InN quantum wells
Pan, Wei; Dimakis, Emmanouil; Wang, George T.; ...
2014-11-24
We report in this letter experimental results that confirm the two-dimensional nature of the electron systems in monolayer InN quantum wells embedded in GaN barriers. The electron density and mobility of the two-dimensional electron system (2DES) in these InN quantum wells are 5×10 15 cm -2 and 420 cm 2 /Vs, respectively. Moreover, the diagonal resistance of the 2DES shows virtually no temperature dependence in a wide temperature range, indicating the topological nature of the 2DES.
Jensen, Roxanne E.; Rothrock, Nan E.; DeWitt, Esi Morgan; Spiegel, Brennan; Tucker, Carole A.; Crane, Heidi M.; Forrest, Christopher B.; Patrick, Donald L.; Fredericksen, Rob; Shulman, Lisa M.; Cella, David; Crane, Paul K.
2016-01-01
Background Patient-reported outcomes (PROs) are gaining recognition as key measures for improving the quality of patient care in clinical care settings. Three factors have made the implementation of PROs in clinical care more feasible: increased use of modern measurement methods in PRO design and validation, rapid progression of technology (e.g., touch screen tablets, Internet accessibility, and electronic health records (EHRs)), and greater demand for measurement and monitoring of PROs by regulators, payers, accreditors, and professional organizations. As electronic PRO collection and reporting capabilities have improved, the challenges of collecting PRO data have changed. Objectives To update information on PRO adoption considerations in clinical care, highlighting electronic and technical advances with respect to measure selection, clinical workflow, data infrastructure, and outcomes reporting. Methods Five practical case studies across diverse healthcare settings and patient populations are used to explore how implementation barriers were addressed to promote the successful integration of PRO collection into the clinical workflow. The case studies address selecting and reporting of relevant content, workflow integration, pre-visit screening, effective evaluation, and EHR integration. Conclusions These case studies exemplify elements of well-designed electronic systems, including response automation, tailoring of item selection and reporting algorithms, flexibility of collection location, and integration with patient health care data elements. They also highlight emerging logistical barriers in this area, such as the need for specialized technological and methodological expertise, and design limitations of current electronic data capture systems. PMID:25588135
DOT National Transportation Integrated Search
2003-02-01
This report summarizes the findings and recommendations of the utilization and operational analysis of the electronic toll collection (ETC) - FasTrak - system on the seven state-owned bridges in the Bay Area. At present, there are a total of 68 toll ...
Comprehensive Field Test and Evaluation of an Electronic Signpost AVM System. Volume I. Test Results
DOT National Transportation Integrated Search
1977-08-01
The report covers the activities of Phase I which involved the installation and test of a HI3 AVM System in Philadelphia, Pennsylvania, during the winter of 1976-1977. A summary report on all systems tested is Experiments on four different techniques...
NASA Astrophysics Data System (ADS)
Hoskins, Douglas; Snead, Robert
1988-05-01
This report details the results of an electromagnetic compatibility test on the SCI Systems Data Acquisition and Control Assembly (DACA). This assembly is an electronic processor which controls the central communication link from the Tethered Satellite System (TSS) to the Space Transportation System Orbiter Space Shuttle.
49 CFR 585.86 - Reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PHASE-IN REPORTING REQUIREMENTS Electronic Stability Control System Phase-In Reporting Requirements § 585.86 Reporting requirements. (a) General reporting..., or, at the manufacturer's option, for the current production year. A new manufacturer that has not...
49 CFR 585.86 - Reporting requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PHASE-IN REPORTING REQUIREMENTS Electronic Stability Control System Phase-In Reporting Requirements § 585.86 Reporting requirements. (a) General reporting..., or, at the manufacturer's option, for the current production year. A new manufacturer that has not...
NASA Tech Briefs, April 1997. Volume 21, No. 4
NASA Technical Reports Server (NTRS)
1997-01-01
Topics covered include: Video and Imaging; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, December 1993. Volume 17, No. 12
NASA Technical Reports Server (NTRS)
1993-01-01
Topics covered include: High-Performance Computing; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, April 2000. Volume 24, No. 4
NASA Technical Reports Server (NTRS)
2000-01-01
Topics covered include: Imaging/Video/Display Technology; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Bio-Medical; Test and Measurement; Mathematics and Information Sciences; Books and Reports.
NASA Tech Briefs, October 1997. Volume 21, No. 10
NASA Technical Reports Server (NTRS)
1997-01-01
Topics covered include: Sensors/Imaging; Mechanical Components; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Software; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, April 1994. Volume 18, No. 4
NASA Technical Reports Server (NTRS)
1994-01-01
Topics covered: Advanced Composites and Plastics; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, March 1994. Volume 18, No. 3
NASA Technical Reports Server (NTRS)
1994-01-01
Topics include: Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, August 1996. Volume 20, No. 8
NASA Technical Reports Server (NTRS)
1996-01-01
Topics covered include: Graphics and Simulation; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, March 2000. Volume 24, No. 3
NASA Technical Reports Server (NTRS)
2000-01-01
Topics include: Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, March 1997. Volume 21, No. 3
NASA Technical Reports Server (NTRS)
1997-01-01
Topics: Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
2016-06-23
The Food and Drug Administration (FDA) is announcing the availability of its FDA Adverse Event Reporting System (FAERS) Regional Implementation Specifications for the International Conference on Harmonisation (ICH) E2B(R3) Specification. FDA is making this technical specifications document available to assist interested parties in electronically submitting individual case safety reports (ICSRs) (and ICSR attachments) to the Center for Drug Evaluation and Research (CDER) and the Center for Biologics Evaluation and Research (CBER). This document, entitled "FDA Regional Implementation Specifications for ICH E2B(R3) Implementation: Postmarket Submission of Individual Case Safety Reports (ICSRs) for Drugs and Biologics, Excluding Vaccines" supplements the "E2B(R3) Electronic Transmission of Individual Case Safety Reports (ICSRs) Implementation Guide--Data Elements and Message Specification" final guidance for industry and describes FDA's technical approach for receiving ICSRs, for incorporating regionally controlled terminology, and for adding region-specific data elements when reporting to FAERS.
2013-09-27
Electronic reporting of laboratory results to public health agencies can improve public health surveillance for reportable diseases and conditions by making reporting more timely and complete. Since 2010, CDC has provided funding to 57 state, local, and territorial health departments through the Epidemiology and Laboratory Capacity for Infectious Diseases cooperative agreement to assist with improving electronic laboratory reporting (ELR) from clinical and public health laboratories to public health agencies. As part of this agreement, CDC and state and large local health departments are collaborating to monitor ELR implementation in the United States by developing data from each jurisdiction regarding total reporting laboratories, laboratories sending ELR by disease category and message format, and the number of ELR laboratory reports compared with the total number of laboratory reports. At the end of July 2013, 54 of the 57 jurisdictions were receiving at least some laboratory reports through ELR, and approximately 62% of 20 million laboratory reports were being received electronically, compared with 54% in 2012. Continued progress will require collaboration between clinical laboratories, laboratory information management system (LIMS) vendors, and public health agencies.
Enhanced Learning through Electronic Communities: A Research Review.
ERIC Educational Resources Information Center
Burgstahler, Sheryl; Swift, Catherine
This report, in support of the project "Enhanced Learning through Electronic Communities," investigated successful practices of electronic communities. A literature review was conducted and a survey was sent to 15 system operators of networks that had a community-based focus with ancillary educational components and networks that focused primarily…
SpecialNet. A National Computer-Based Communications Network.
ERIC Educational Resources Information Center
Morin, Alfred J.
1986-01-01
"SpecialNet," a computer-based communications network for educators at all administrative levels, has been established and is managed by National Systems Management, Inc. Users can send and receive electronic mail, share information on electronic bulletin boards, participate in electronic conferences, and send reports and other documents to each…
Research Reports: 1983 NASA/ASEE Summer Faculty Fellowship Program
NASA Technical Reports Server (NTRS)
Karr, G. R.; Dozier, J. B.; Osborn, L.; Freeman, M.
1983-01-01
Thirty-five technical reports contain results of investigations in information and electronic systems; materials and processing; systems dynamics; structures and propulsion; and space sciences. Ecology at KSC, satellite de-spin, and the X-ray source monitor were also studied.
L a A l O3 / S r T i O3 -A Tale of Two Magnetisms
NASA Astrophysics Data System (ADS)
Pai, Yun-Yi; Tylan-Tyler, Anthony; Irvin, Patrick; Levy, Jeremy
Ten years since the first report of magnetism by Brinkman et al., a unified picture of magnetism at the two-dimensional electron system (2DES) between LaAlO3 / SrTiO3 is still lacking. The understanding is further hindered by the complex interplay of magnetism and many other aspects of this system: multi-band superconductivity, quantum paraelectricity, multiferroicity, to name but a few. We argue that the reported magnetic signatures in this system can come from two principal origins: (1) a ferromagnetic long-range order resulting from local magnetic moments mediated by itinerant electrons, and (2) metamagnetic phenomena associated with electron pairing without superconductivity. Finally, we discuss possible experimental tests of this framework. We gratefully acknowledge financial support from NSF (DMR-1124131, DMR-1609519) and ONR N00014-15-1-2847.
Nanographenes as electron-deficient cores of donor-acceptor systems.
Liu, Yu-Min; Hou, Hao; Zhou, Yan-Zhen; Zhao, Xin-Jing; Tang, Chun; Tan, Yuan-Zhi; Müllen, Klaus
2018-05-15
Conjugation of nanographenes (NGs) with electro-active molecules can establish donor-acceptor π-systems in which the former generally serve as the electron-donating moieties due to their electronic-rich nature. In contrast, here we report a series of reversed donor-acceptor structures are obtained by C-N coupling of electron-deficient perchlorinated NGs with electron-rich anilines. Selective amination at the vertexes of the NGs is unambiguously shown through X-ray crystallography. By varying the donating ability of the anilino groups, the optical and assembly properties of donor-acceptor NGs can be finely modulated. The electron-deficient concave core of the resulting conjugates can host electron-rich guest molecules by intermolecular donor-acceptor interactions and gives rise to charge-transfer supramolecular architectures.
Rapid Implementation of Inpatient Electronic Physician Documentation at an Academic Hospital
Hahn, J.S.; Bernstein, J.A.; McKenzie, R.B.; King, B.J.; Longhurst, C.A.
2012-01-01
Electronic physician documentation is an essential element of a complete electronic medical record (EMR). At Lucile Packard Children’s Hospital, a teaching hospital affiliated with Stanford University, we implemented an inpatient electronic documentation system for physicians over a 12-month period. Using an EMR-based free-text editor coupled with automated import of system data elements, we were able to achieve voluntary, widespread adoption of the electronic documentation process. When given the choice between electronic versus dictated report creation, the vast majority of users preferred the electronic method. In addition to increasing the legibility and accessibility of clinical notes, we also decreased the volume of dictated notes and scanning of handwritten notes, which provides the opportunity for cost savings to the institution. PMID:23620718
77 FR 44592 - Atlantic Highly Migratory Species; Electronic Dealer Reporting System Workshop
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-30
... reporting system will allow dealers to submit Atlantic sharks, swordfish, and BAYS tuna data on a more real... to give sufficient time for dealers to adjust to implementation of the new system and the additional... HMS. In order to give sufficient time for dealers to adjust to implementation of the new system and...
Interference Cancellation System Design Using GNU Radio
2015-12-01
ARL-TR-7546 ● DEC 2015 US Army Research Laboratory Interference Cancellation System Design Using GNU Radio by Jan Paolo...Interference Cancellation System Design Using GNU Radio by Jan Paolo Acosta Sensors and Electron Devices Directorate, ARL...REPORT DATE (DD-MM-YYYY) December 2015 2. REPORT TYPE Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Interference Cancellation System
Jensen, Roxanne E; Snyder, Claire F; Basch, Ethan; Frank, Lori; Wu, Albert W
2016-11-01
In recent years, patient-reported outcomes have become increasingly collected and integrated into electronic health records. However, there are few cross-cutting recommendations and limited guidance available in this rapidly developing research area. Our goal is to report key findings from a 2013 Patient-Centered Outcomes Research Institute workshop on this topic and a summary of actions that followed from the workshop, and present resulting recommendations that address patient, clinical and research/quality improvement barriers to regular use. These findings provide actionable guidance across research and practice settings to promote and sustain widespread adoption of patient-reported outcomes across patient populations, healthcare settings and electronic health record systems.
E-Business Reporting: Towards a Global Standard for Financial Reporting Systems Using XBRL
ERIC Educational Resources Information Center
Long, Margaret J.
2013-01-01
Reporting systems can provide transparency into financial markets necessary for a sustainable, prosperous global economy. The most widely used global platform for exchanging electronic information about companies to regulatory bodies is XBRL. Standards for this platform are in the process of becoming legally harmonized, but not all countries are…
12 CFR 620.4 - Preparing and providing the annual report.
Code of Federal Regulations, 2010 CFR
2010-01-01
....4 Section 620.4 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM DISCLOSURE TO... institution of the Farm Credit System must: (1) Prepare and send to the Farm Credit Administration an... copy of its annual report on its Web site when it sends the report electronically to the Farm Credit...
NASA Tech Briefs, July 1994. Volume 18, No. 7
NASA Technical Reports Server (NTRS)
1994-01-01
Topics covered include: Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports
NASA Tech Briefs, May 1997. Volume 21, No. 5
NASA Technical Reports Server (NTRS)
1997-01-01
Topics covered include: Advanced Composites, Plastics and Metals; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
NASA Tech Briefs, April 1996. Volume 20, No. 4
NASA Technical Reports Server (NTRS)
1996-01-01
Topics covered include: Advanced Composites and Plastics; Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information; Books and Reports.
NASA Tech Briefs, October 1994. Volume 18, No. 10
NASA Technical Reports Server (NTRS)
1994-01-01
Topics: Data Acquisition and Analysis; Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences; Books and Reports
Precision Attitude Determination System (PADS) design and analysis. Two-axis gimbal star tracker
NASA Technical Reports Server (NTRS)
1973-01-01
Development of the Precision Attitude Determination System (PADS) focused chiefly on the two-axis gimballed star tracker and electronics design improved from that of Precision Pointing Control System (PPCS), and application of the improved tracker for PADS at geosynchronous altitude. System design, system analysis, software design, and hardware design activities are reported. The system design encompasses the PADS configuration, system performance characteristics, component design summaries, and interface considerations. The PADS design and performance analysis includes error analysis, performance analysis via attitude determination simulation, and star tracker servo design analysis. The design of the star tracker and electronics are discussed. Sensor electronics schematics are included. A detailed characterization of the application software algorithms and computer requirements is provided.
1983-08-01
Maccagno, and A. Miller, "Interaction of Acoustic Waves and Ferroelastic Domain Walls," Ferroelectrics (to be published). 3. J. A. Armstrong , et al...34 Preprint (November 1982). Also: Published in Electronics Letters, 18.A 999 (11 November 1982). 3513 S.A. Newton, J.E. Bowers, G. Kotler , Litton Systems, and
Effects of vibration on the readability of an electronic flight instrument display
NASA Astrophysics Data System (ADS)
Viveash, Jacqueline P.; Cable, A. N.; King, S. K.; Stott, J. R.; Wright, R.
1993-12-01
An in-flight icing incident involving a BAe advanced turboprop (ATP) aircraft led to severe vibration of the airframe and a loss of aerodynamic control. During the period of vibration the pilot reported a specific pattern of image break up on the electronic flight instrument system (EFIS). Three experiments to investigate this visual effect are reported.
The Association between Students' Use of an Electronic Voting System and their Learning Outcomes
ERIC Educational Resources Information Center
Kennedy, G. E.; Cutts, Q. I.
2005-01-01
This paper reports on the use of an electronic voting system (EVS) in a first-year computing science subject. Previous investigations suggest that students' use of an EVS would be positively associated with their learning outcomes. However, no research has established this relationship empirically. This study sought to establish whether there was…
Using Computer Conferencing and Electronic Mail to Facilitate Group Projects.
ERIC Educational Resources Information Center
Anderson, Margaret D.
1996-01-01
Reports on the use of electronic mail and an electronic conferencing system to conduct group projects in three educational psychology courses at the State University of New York College at Cortland. Course design is explained and group project design is described, including assignments and oral presentations during regular class sessions.…
Healthcare Students' Perceptions of Electronic Feedback through GradeMark®
ERIC Educational Resources Information Center
Watkins, Diane; Dummer, Paul; Hawthorne, Kamila; Cousins, Judy; Emmett, Catherine; Johnson, Mike
2014-01-01
This paper reports on the findings from a study undertaken to explore students' perceptions of the timeliness, accessibility, consistency, and quality of feedback and grading received electronically. The system used was GradeMark®, an electronic tool available through the plagiarism software provider, Turnitin®. 296 students from the Schools of…
Doctors' use of electronic medical records systems in hospitals: cross sectional survey
Lærum, Hallvard; Ellingsen, Gunnar; Faxvaag, Arild
2001-01-01
Objectives To compare the use of three electronic medical records systems by doctors in Norwegian hospitals for general clinical tasks. Design Cross sectional questionnaire survey. Semistructured telephone interviews with key staff in information technology in each hospital for details of local implementation of the systems. Setting 32 hospital units in 19 Norwegian hospitals with electronic medical records systems. Participants 227 (72%) of 314 hospital doctors responded, equally distributed between the three electronic medical records systems. Main outcome measures Proportion of respondents who used the electronic system, calculated for each of 23 tasks; difference in proportions of users of different systems when functionality of systems was similar. Results Most tasks listed in the questionnaire (15/23) were generally covered with implemented functions in the electronic medical records systems. However, the systems were used for only 2-7 of the tasks, mainly associated with reading patient data. Respondents showed significant differences in frequency of use of the different systems for four tasks for which the systems offered equivalent functionality. The respondents scored highly in computer literacy (72.2/100), and computer use showed no correlation with respondents' age, sex, or work position. User satisfaction scores were generally positive (67.2/100), with some difference between the systems. Conclusions Doctors used electronic medical records systems for far fewer tasks than the systems supported. What is already known on this topicElectronic information systems in health care have not undergone systematic evaluation, and few comparisons between electronic medical records systems have been madeGiven the information intensive nature of clinical work, electronic medical records systems should be of help to doctors for most clinical tasksWhat this study addsDoctors in Norwegian hospitals reported a low level of use of all electronic medical records systemsThe systems were mainly used for reading patient data, and doctors used the systems for less than half of the tasks for which the systems were functionalAnalyses of actual use of electronic medical records provide more information than user satisfaction or functionality of such records systems PMID:11739222
Fajardo, Geroncio C; Posid, Joseph; Papagiotas, Stephen; Lowe, Luis
2015-01-01
There have been periodic electronic news media reports of potential bioterrorism-related incidents involving unknown substances (often referred to as "white powder") since the 2001 intentional dissemination of Bacillus anthracis through the U.S. Postal System. This study reviewed the number of unknown "white powder" incidents reported online by the electronic news media and compared them with unknown "white powder" incidents reported to the U.S. Centers for Disease Control and Prevention (CDC) and the U.S. Federal Bureau of Investigation (FBI) during a 2-year period from June 1, 2009 and May 31, 2011. Results identified 297 electronic news media reports, 538 CDC reports, and 384 FBI reports of unknown "white powder." This study showed different unknown "white powder" incidents captured by each of the three sources. However, the authors could not determine the public health implications of this discordance. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
NASA Tech Briefs, July 1995. Volume 19, No. 7
NASA Technical Reports Server (NTRS)
1995-01-01
Topics include: mechanical components, electronic components and circuits, electronic systems, physical sciences, materials, computer programs, mechanics, machinery, manufacturing/fabrication, mathematics and information sciences, book and reports, and a special section of Federal laboratory computing Tech Briefs.
NASA Tech Briefs, June 1995. Volume 19, No. 6
NASA Technical Reports Server (NTRS)
1995-01-01
Topics include: communications technology, electronic components and circuits, electronic systems, physical sciences, materials, computer programs, mechanics, machinery, manufacturing/fabrication, mathematics and information sciences, life sciences, books and reports, a special section of laser Tech Briefs.
A 20-liter test stand with gas purification for liquid argon research
Li, Y.; Thorn, C.; Tang, W.; ...
2016-06-06
Here, we describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). Moreover, this system utilizes a simple, cost-effective gas argon (GAr) purification to achieve high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. Finally, a gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.
A 20-liter test stand with gas purification for liquid argon research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Y.; Thorn, C.; Tang, W.
Here, we describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). Moreover, this system utilizes a simple, cost-effective gas argon (GAr) purification to achieve high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. Finally, a gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-30
... except infant formula and dietary supplements. Other mandatory reporting systems exist for problems with infant formula and dietary supplements. Submissions to the Reportable Food electronic portal provide...
Bruins, Marjan J; Ruijs, Gijs J H M; Wolfhagen, Maurice J H M; Bloembergen, Peter; Aarts, Jos E C M
2011-03-30
Clinicians view the accuracy of test results and the turnaround time as the two most important service aspects of the clinical microbiology laboratory. Because of the time needed for the culturing of infectious agents, final hardcopy culture results will often be available too late to have a significant impact on early antimicrobial therapy decisions, vital in infectious disease management. The clinical microbiologist therefore reports to the clinician clinically relevant preliminary results at any moment during the diagnostic process, mostly by telephone. Telephone reporting is error prone, however. Electronic reporting of culture results instead of reporting on paper may shorten the turnaround time and may ensure correct communication of results. The purpose of this study was to assess the impact of the implementation of electronic reporting of final microbiology results on medical decision making. In a pre- and post-interview study using a semi-structured design we asked medical specialists in our hospital about their use and appreciation of clinical microbiology results reporting before and after the implementation of an electronic reporting system. Electronic reporting was highly appreciated by all interviewed clinicians. Major advantages were reduction of hardcopy handling and the possibility to review results in relation to other patient data. Use and meaning of microbiology reports differ significantly between medical specialties. Most clinicians need preliminary results for therapy decisions quickly. Therefore, after the implementation of electronic reporting, telephone consultation between clinician and microbiologist remained the key means of communication. Overall, electronic reporting increased the workflow efficiency of the medical specialists, but did not have an impact on their decision-making. © 2011 Bruins et al; licensee BioMed Central Ltd.
Usability Testing of a National Substance Use Screening Tool Embedded in Electronic Health Records.
Press, Anne; DeStio, Catherine; McCullagh, Lauren; Kapoor, Sandeep; Morley, Jeanne; Conigliaro, Joseph
2016-07-08
Screening, brief intervention, and referral to treatment (SBIRT) is currently being implemented into health systems nationally via paper and electronic methods. The purpose of this study was to evaluate the integration of an electronic SBIRT tool into an existing paper-based SBIRT clinical workflow in a patient-centered medical home. Usability testing was conducted in an academic ambulatory clinic. Two rounds of usability testing were done with medical office assistants (MOAs) using a paper and electronic version of the SBIRT tool, with two and four participants, respectively. Qualitative and quantitative data was analyzed to determine the impact of both tools on clinical workflow. A second round of usability testing was done with the revised electronic version and compared with the first version. Personal workflow barriers cited in the first round of testing were that the electronic health record (EHR) tool was disruptive to patient's visits. In Round 2 of testing, MOAs reported favoring the electronic version due to improved layout and the inclusion of an alert system embedded in the EHR. For example, using the system usability scale (SUS), MOAs reported a grade "1" for the statement, "I would like to use this system frequently" during the first round of testing but a "5" during the second round of analysis. The importance of testing usability of various mediums of tools used in health care screening is highlighted by the findings of this study. In the first round of testing, the electronic tool was reported as less user friendly, being difficult to navigate, and time consuming. Many issues faced in the first generation of the tool were improved in the second generation after usability was evaluated. This study demonstrates how usability testing of an electronic SBRIT tool can help to identify challenges that can impact clinical workflow. However, a limitation of this study was the small sample size of MOAs that participated. The results may have been biased to Northwell Health workers' perceptions of the SBIRT tool and their specific clinical workflow.
ERIC Educational Resources Information Center
California Univ., Oakland. Div. of Library Automation.
This report on options for developing the University of California (UC) MELVYL online library system discusses the system in relationship to the current environment, including national and network information resources, electronic publishing, campus libraries, and changing user expectations; and places the growth of the MELVYL system in the…
Evidence for electronic health record systems in physical therapy.
Vreeman, Daniel J; Taggard, Samuel L; Rhine, Michael D; Worrell, Teddy W
2006-03-01
With increasing pressures to better manage clinical information, we investigated the role of electronic health record (EHR) systems in physical therapist practice through a critical review of the literature. We reviewed studies that met our predefined criteria after independent review by 3 authors. The investigators in all of the reviewed studies reported benefits, including improved reporting, operational efficiency, interdepartmental communication, data accuracy, and capability for future research. In 7 studies, the investigators reported barriers, including challenges with behavior modification, equipment inadequacy, and training. The investigators in all studies reported key success factors, including end-user participation, adequate training, workflow analysis, and data standardization. This review suggests that EHRs have potential benefits for physical therapists. The authors formed the following recommendations based on the studies' themes: (1) incorporate workflow analysis into system design and implementation; (2) include end users, especially clinicians, in system development; (3) devote significant resources for training; (4) plan and test carefully to ensure adequate software and hardware performance; and (5) commit to data standards.
NASA Astrophysics Data System (ADS)
Dizhur, E.; Voronovskii, A.; Kostyleva, I.; Kotel'nikov, I.; Zaitsev-Zotov, S.
2011-12-01
We report the results of our recent experimental studies concerned with electron systems of lower dimensionality the conductivity of which may be toggled between metallic and insulating regime appliing high pressure. The objects under present study include: a) tunneling through Shottky barrier into two-dimension (2D) electron system formed in the δ-doped layer in GaAs under hydrostatic pressure up to 3 GPa in a cylinder-piston cell; b) quasi-one-dimension (1D) `insulator' crystals NbS3 which obtain metallic conductivity type at pressures above 5.5 GPa in `toroid' anvils.
NASA Technical Reports Server (NTRS)
Cooper, D. M.
1979-01-01
Electronic transition moments of seven C2 singlet and triplet band systems in the 0.2-1.2 micron spectral region were measured. The measurements were made in emission behind incident shock waves in C2H2-argon mixtures. Narrow bandpass radiometers were used to obtain absolute measurements of shock-excited C2 radiation from which absolute electronic transition moments are derived by a synthetic spectrum analysis. New results are reported for the Ballik-Ramsay, Phillips, Swan, Deslandres-d'Azambuja, Fox-Herzberg, Mulliken, and Freymark systems.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-08
... matching to meet the reporting required by 7 CFR 210.17(g). The form is an intrinsic part of the accounting system currently being used by the subject programs to ensure proper reimbursement as well as to... reporting system and 100 percent of the information is collected through electronic means. The instructions...
NASA Technical Reports Server (NTRS)
Tuey, Richard C.; Moore, Fred W.; Ryan, Christine A.
1995-01-01
The report is presented in four sections: The Introduction describes the duplicating configuration under evaluation and the Background contains a chronological description of the evaluation segmented by phases 1 and 2. This section includes the evaluation schedule, printing and duplicating requirements, storage and communication requirements, electronic publishing system configuration, existing processes and proposed processes, billing rates, costs and productivity analysis, and the return on investment based upon the data gathered to date. The third section contains the phase 1 comparative cost and productivity analysis. This analysis demonstrated that LaRC should proceed with a 90-day evaluation of the DocuTech and follow with a phase 2 cycle to actually demonstrate that the proposed system would meet the needs of LaRC's printing and duplicating requirements, benchmark results, cost comparisons, benchmark observations, and recommendations. These are documented after the recommendations.
NASA Astrophysics Data System (ADS)
Meier, E.; Biedron, S. G.; LeBlanc, G.; Morgan, M. J.
2011-03-01
This paper reports the results of an advanced algorithm for the optimization of electron beam parameters in Free Electron Laser (FEL) Linacs. In the novel approach presented in this paper, the system uses state of the art developments in video games to mimic an operator's decisions to perform an optimization task when no prior knowledge, other than constraints on the actuators is available. The system was tested for the simultaneous optimization of the energy spread and the transmission of the Australian Synchrotron Linac. The proposed system successfully increased the transmission of the machine from 90% to 97% and decreased the energy spread of the beam from 1.04% to 0.91%. Results of a control experiment performed at the new FERMI@Elettra FEL is also reported, suggesting the adaptability of the scheme for beam-based control.
Ashley, L; Jones, H; Thomas, J; Forman, D; Newsham, A; Morris, E; Johnson, O; Velikova, G; Wright, P
2011-01-01
Background: Understanding the psychosocial challenges of cancer survivorship, and identifying which patients experience ongoing difficulties, is a key priority. The ePOCS (electronic patient-reported outcomes from cancer survivors) project aims to develop and evaluate a cost-efficient, UK-scalable electronic system for collecting patient-reported outcome measures (PROMs), at regular post-diagnostic timepoints, and linking these with clinical data in cancer registries. Methods: A multidisciplinary team developed the system using agile methods. Design entailed process mapping the system's constituent parts, data flows and involved human activities, and undertaking usability testing. Informatics specialists built new technical components, including a web-based questionnaire tool and tracking database, and established component-connecting data flows. Development challenges were overcome, including patient usability and data linkage and security. Results: We have developed a system in which PROMs are completed online, using a secure questionnaire administration tool, accessed via a public-facing website, and the responses are linked and stored with clinical registry data. Patient monitoring and communications are semiautomated via a tracker database, and patient correspondence is primarily Email-based. The system is currently honed for clinician-led hospital-based patient recruitment. Conclusions: A feasibility test study is underway. Although there are possible challenges to sustaining and scaling up ePOCS, the system has potential to support UK epidemiological PROMs collection and clinical data linkage. PMID:22048035
Public Health Surveillance and Meaningful Use Regulations: A Crisis of Opportunity
Sundwall, David N.
2012-01-01
The Health Information Technology for Economic and Clinical Health Act is intended to enhance reimbursement of health care providers for meaningful use of electronic health records systems. This presents both opportunities and challenges for public health departments. To earn incentive payments, clinical providers must exchange specified types of data with the public health system, such as immunization and syndromic surveillance data and notifiable disease reporting. However, a crisis looms because public health’s information technology systems largely lack the capabilities to accept the types of data proposed for exchange. Cloud computing may be a solution for public health information systems. Through shared computing resources, public health departments could reap the benefits of electronic reporting within federal funding constraints. PMID:22390523
Public health surveillance and meaningful use regulations: a crisis of opportunity.
Lenert, Leslie; Sundwall, David N
2012-03-01
The Health Information Technology for Economic and Clinical Health Act is intended to enhance reimbursement of health care providers for meaningful use of electronic health records systems. This presents both opportunities and challenges for public health departments. To earn incentive payments, clinical providers must exchange specified types of data with the public health system, such as immunization and syndromic surveillance data and notifiable disease reporting. However, a crisis looms because public health's information technology systems largely lack the capabilities to accept the types of data proposed for exchange. Cloud computing may be a solution for public health information systems. Through shared computing resources, public health departments could reap the benefits of electronic reporting within federal funding constraints.
Jensen, Roxanne E; Snyder, Claire F; Basch, Ethan; Frank, Lori; Wu, Albert W
2016-01-01
In recent years, patient-reported outcomes have become increasingly collected and integrated into electronic health records. However, there are few cross-cutting recommendations and limited guidance available in this rapidly developing research area. Our goal is to report key findings from a 2013 Patient-Centered Outcomes Research Institute workshop on this topic and a summary of actions that followed from the workshop, and present resulting recommendations that address patient, clinical and research/quality improvement barriers to regular use. These findings provide actionable guidance across research and practice settings to promote and sustain widespread adoption of patient-reported outcomes across patient populations, healthcare settings and electronic health record systems. PMID:27586855
NASA Tech Briefs, July 2000. Volume 24, No. 7
NASA Technical Reports Server (NTRS)
2000-01-01
Topics covered include: Data Acquisition; Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Test and Measurement; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.
Joint Services Electronics Program.
1988-02-29
REPORT DOCUMENTATION PAG6E I a lb. RESTRICTIVE MARKINGS ~CI~LAI U4ll- iL --- ’ ,, J,,-.,, , 3 DISTRIBUTION / AVAILABILITY OF REPORT Approved for public...Proximity Gettering with Mega-Electron-Volt-Carbon Implantation 4 GaAs Probing: Surface Properties to 3 -D Field Mapping 8 Miniaturized of Josephson Logic...Materials Studies 21 HFD. 3 . Basic Techniques for Electromagnetic Scattering and Radiation 23 Transmission Line Systems for Millimeter/Submillimeter
ERIC Educational Resources Information Center
Tawfik, M.; Sancristobal, E.; Martin, S.; Gil, R.; Diaz, G.; Colmenar, A.; Peire, J.; Castro, M.; Nilsson, K.; Zackrisson, J.; Hakansson, L.; Gustavsson, I.
2013-01-01
This paper reports on a state-of-the-art remote laboratory project called Virtual Instrument Systems in Reality (VISIR). VISIR allows wiring and measuring of electronic circuits remotely on a virtual workbench that replicates physical circuit breadboards. The wiring mechanism is developed by means of a relay switching matrix connected to a PCI…
Field Programmable Gate Array Control of Power Systems in Graduate Student Laboratories
2008-03-01
NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited FIELD PROGRAMMABLE...REPORT TYPE AND DATES COVERED Master’s Thesis 4. TITLE AND SUBTITLE Field Programmable Gate Array Control of Power Systems in Graduate Student...Electronics curriculum track is the development of a design center that explores Field Programmable Gate Array (FPGA) control of power electronics
ERIC Educational Resources Information Center
Rastorfer, Darl
2011-01-01
From February 2008 through April 2011, School Health Connection, a program of the Louisiana Public Health Institute, developed an electronic health information management system for newly established school-based health centers in Greater New Orleans. School Health Connection was established as part of a broader effort to restore community health…
Surveys of research in the Chemistry Division, Argonne National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grazis, B.M.
1992-01-01
Research reports are presented on reactive intermediates in condensed phase (radiation chemistry, photochemistry), electron transfer and energy conversion, photosynthesis and solar energy conversion, metal cluster chemistry, chemical dynamics in gas phase, photoionization-photoelectrons, characterization and reactivity of coal and coal macerals, premium coal sample program, chemical separations, heavy elements coordination chemistry, heavy elements photophysics/photochemistry, f-electron interactions, radiation chemistry of high-level wastes (gas generation in waste tanks), ultrafast molecular electronic devices, and nuclear medicine. Separate abstracts have been prepared. Accelerator activites and computer system/network services are also reported.
Surveys of research in the Chemistry Division, Argonne National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grazis, B.M.
1992-11-01
Research reports are presented on reactive intermediates in condensed phase (radiation chemistry, photochemistry), electron transfer and energy conversion, photosynthesis and solar energy conversion, metal cluster chemistry, chemical dynamics in gas phase, photoionization-photoelectrons, characterization and reactivity of coal and coal macerals, premium coal sample program, chemical separations, heavy elements coordination chemistry, heavy elements photophysics/photochemistry, f-electron interactions, radiation chemistry of high-level wastes (gas generation in waste tanks), ultrafast molecular electronic devices, and nuclear medicine. Separate abstracts have been prepared. Accelerator activites and computer system/network services are also reported.
[Computer-aided Diagnosis and New Electronic Stethoscope].
Huang, Mei; Liu, Hongying; Pi, Xitian; Ao, Yilu; Wang, Zi
2017-05-30
Auscultation is an important method in early-diagnosis of cardiovascular disease and respiratory system disease. This paper presents a computer-aided diagnosis of new electronic auscultation system. It has developed an electronic stethoscope based on condenser microphone and the relevant intelligent analysis software. It has implemented many functions that combined with Bluetooth, OLED, SD card storage technologies, such as real-time heart and lung sounds auscultation in three modes, recording and playback, auscultation volume control, wireless transmission. The intelligent analysis software based on PC computer utilizes C# programming language and adopts SQL Server as the background database. It has realized play and waveform display of the auscultation sound. By calculating the heart rate, extracting the characteristic parameters of T1, T2, T12, T11, it can analyze whether the heart sound is normal, and then generate diagnosis report. Finally the auscultation sound and diagnosis report can be sent to mailbox of other doctors, which can carry out remote diagnosis. The whole system has features of fully function, high portability, good user experience, and it is beneficial to promote the use of electronic stethoscope in the hospital, at the same time, the system can also be applied to auscultate teaching and other occasions.
Development and Evaluation of an Adaptive Computerized Training System (ACTS). R&D Report 78-1.
ERIC Educational Resources Information Center
Knerr, Bruce W.; Nawrocki, Leon H.
This report describes the development of a computer based system designed to train electronic troubleshooting procedures. The ACTS uses artificial intelligence techniques to develop models of student and expert troubleshooting behavior as they solve a series of troubleshooting problems on the system. Comparisons of the student and expert models…
Electronic Equipment Proposal to Improve the Photovoltaic Systems Efficiency
NASA Astrophysics Data System (ADS)
Flores-Mena, J. E.; Juárez Morán, L. A.; Díaz Reyes, J.
2011-05-01
This paper reports a new technique proposal to improve the photovoltaic systems. It was made to design and implement an electronic system that will detect, capture, and transfer the maximum power of the photovoltaic (PV) panel to optimize the supplied power of a solar panel. The electronic system works on base technical proposal of electrical sweeping of electric characteristics using capacitive impedance. The maximum power is transformed and the solar panel energy is sent to an automotive battery. This electronic system reduces the energy lost originated when the solar radiation level decreases or the PV panel temperature is increased. This electronic system tracks, captures, and stores the PV module's maximum power into a capacitor. After, a higher voltage level step-up circuit was designed to increase the voltage of the PV module's maximum power and then its current can be sent to a battery. The experimental results show that the developed electronic system has 95% efficiency. The measurement was made to 50 W, the electronic system works rightly with solar radiation rate from 100 to 1,000 W m - 2 and the PV panel temperature rate changed from 1 to 75°C. The main advantage of this electronic system compared with conventional methods is the elimination of microprocessors, computers, and sophisticated numerical approximations, and it does not need any small electrical signals to track the maximum power. The proposed method is simple, fast, and it is also cheaper.
Commercialization of an S-band standing-wave electron accelerator for industrial applications
NASA Astrophysics Data System (ADS)
Moon, Jin-Hyeok; Kwak, Gyeong-Il; Han, Jae-Ik; Lee, Gyu-Baek; Jeon, Seong-Hwan; Kim, Jae-Young; Hwang, Cheol-Bin; Lee, Gi-Yong; Kim, Young-Man; Park, Sung-Ju
2016-09-01
An electron accelerator system has been developed for use in industrial, as well as possible medical, applications. Based on our experiences achieved during prototype system development and various electron beam acceleration tests, we have built a stable and compact system for sales purposes. We have integrated a self-developed accelerating cavity, an E-gun pulse driver, a radio-frequency (RF) power system, a vacuum system, a cooling system, etc. into a frame with a size of 1800 × 1000 × 1500 mm3. The accelerating structure is a side-coupled standing-wave type operating in the π/2 mode (tuned to~3 GHz). The RF power is provided by using a magnetron driven by a solid-state modulator. The electron gun is a triode type with a dispenser cathode (diameter of 11 mm). The system is capable of delivering a maximum 900-W average electron beam power with tight focusing at the target. Until now, we have performed various electron beam tests and X-ray beam tests after having built the system, have completed the beam assessment for commercializations, and have been preparing full-fledged sales activity. This article reports on our system development processes and on some of our early test results for commercializations.
Analyzing Electronic Question/Answer Services: Framework and Evaluations of Selected Services.
ERIC Educational Resources Information Center
White, Marilyn Domas, Ed.
This report develops an analytical framework based on systems analysis for evaluating electronic question/answer or AskA services operated by a wide range of types of organizations, including libraries. Version 1.0 of this framework was applied in June 1999 to a selective sample of 11 electronic question/answer services, which cover a range of…
Multipurpose panel, phase 1, study report. [display utilizing multiplexing and digital techniques
NASA Technical Reports Server (NTRS)
Parkin, W.
1975-01-01
The feasibility of a multipurpose panel which provides a programmable electronic display for changeable panel nomenclature, multiplexes similar indicator display signals to the signal display, and demultiplexes command signals is examined. Topics discussed include: electronic display technology, miniaturized electronic and memory devices, and data management systems which employ digital address and multiplexing.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-10
... Effectiveness of Electronic Stability Control Systems for Cars and LTVs AGENCY: National Highway Traffic Safety... effectiveness of electronic stability control (ESC) for passenger cars and LTVs (light trucks and vans). Safety... probability that a vehicle would be involved in a fatal crash. For passenger cars, the reductions are 5...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 1 2010-07-01 2010-07-01 false How does a state, tribe, or local... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL CROSS-MEDIA ELECTRONIC REPORTING Electronic... state, tribe, or local government that does not have an existing electronic document receiving system...
Collective relaxation processes in atoms, molecules and clusters
NASA Astrophysics Data System (ADS)
Kolorenč, Přemysl; Averbukh, Vitali; Feifel, Raimund; Eland, John
2016-04-01
Electron correlation is an essential driver of a variety of relaxation processes in excited atomic and molecular systems. These are phenomena which often lead to autoionization typically involving two-electron transitions, such as the well-known Auger effect. However, electron correlation can give rise also to higher-order processes characterized by multi-electron transitions. Basic examples include simultaneous two-electron emission upon recombination of an inner-shell vacancy (double Auger decay) or collective decay of two holes with emission of a single electron. First reports of this class of processes date back to the 1960s, but their investigation intensified only recently with the advent of free-electron lasers. High fluxes of high-energy photons induce multiple excitation or ionization of a system on the femtosecond timescale and under such conditions the importance of multi-electron processes increases significantly. We present an overview of experimental and theoretical works on selected multi-electron relaxation phenomena in systems of different complexity, going from double Auger decay in atoms and small molecules to collective interatomic autoionization processes in nanoscale samples.
Allsop, Matthew J; Kite, Suzanne; McDermott, Sarah; Penn, Naomi; Millares-Martin, Pablo; Bennett, Michael I
2016-01-01
Background: The need to improve coordination of care at end of life has driven electronic palliative care coordination systems implementation across the United Kingdom and internationally. No approaches for evaluating electronic palliative care coordination systems use in practice have been developed. Aim: This study outlines and applies an evaluation framework for examining how and when electronic documentation of advance care planning is occurring in end of life care services. Design: A pragmatic, formative process evaluation approach was adopted. The evaluation drew on the Project Review and Objective Evaluation methodology to guide the evaluation framework design, focusing on clinical processes. Setting/participants: Data were extracted from electronic palliative care coordination systems for 82 of 108 general practices across a large UK city. All deaths (n = 1229) recorded on electronic palliative care coordination systems between April 2014 and March 2015 were included to determine the proportion of all deaths recorded, median number of days prior to death that key information was recorded and observations about routine data use. Results: The evaluation identified 26.8% of all deaths recorded on electronic palliative care coordination systems. The median number of days to death was calculated for initiation of an electronic palliative care coordination systems record (31 days), recording a patient’s preferred place of death (8 days) and entry of Do Not Attempt Cardiopulmonary Resuscitation decisions (34 days). Where preferred and actual place of death was documented, these were matching for 75% of patients. Anomalies were identified in coding used during data entry on electronic palliative care coordination systems. Conclusion: This study reports the first methodology for evaluating how and when electronic palliative care coordination systems documentation is occurring. It raises questions about what can be drawn from routine data collected through electronic palliative care coordination systems and outlines considerations for future evaluation. Future evaluations should consider work processes of health professionals using electronic palliative care coordination systems. PMID:27507636
Allsop, Matthew J; Kite, Suzanne; McDermott, Sarah; Penn, Naomi; Millares-Martin, Pablo; Bennett, Michael I
2017-05-01
The need to improve coordination of care at end of life has driven electronic palliative care coordination systems implementation across the United Kingdom and internationally. No approaches for evaluating electronic palliative care coordination systems use in practice have been developed. This study outlines and applies an evaluation framework for examining how and when electronic documentation of advance care planning is occurring in end of life care services. A pragmatic, formative process evaluation approach was adopted. The evaluation drew on the Project Review and Objective Evaluation methodology to guide the evaluation framework design, focusing on clinical processes. Data were extracted from electronic palliative care coordination systems for 82 of 108 general practices across a large UK city. All deaths ( n = 1229) recorded on electronic palliative care coordination systems between April 2014 and March 2015 were included to determine the proportion of all deaths recorded, median number of days prior to death that key information was recorded and observations about routine data use. The evaluation identified 26.8% of all deaths recorded on electronic palliative care coordination systems. The median number of days to death was calculated for initiation of an electronic palliative care coordination systems record (31 days), recording a patient's preferred place of death (8 days) and entry of Do Not Attempt Cardiopulmonary Resuscitation decisions (34 days). Where preferred and actual place of death was documented, these were matching for 75% of patients. Anomalies were identified in coding used during data entry on electronic palliative care coordination systems. This study reports the first methodology for evaluating how and when electronic palliative care coordination systems documentation is occurring. It raises questions about what can be drawn from routine data collected through electronic palliative care coordination systems and outlines considerations for future evaluation. Future evaluations should consider work processes of health professionals using electronic palliative care coordination systems.
Stretchable inorganic nanomembrane electronics for healthcare devices
NASA Astrophysics Data System (ADS)
Kim, Dae-Hyeong; Son, Donghee; Kim, Jaemin
2015-05-01
Flexible or stretchable electronic devices for healthcare technologies have attracted much attention in terms of usefulness to assist doctors in their operating rooms and to monitor patients' physical conditions for a long period of time. Each device to monitor the patients' physiological signals real-time, such as strain, pressure, temperature, and humidity, etc. has been reported recently. However, their limitations are found in acquisition of various physiological signals simultaneously because all the functions are not assembled in one skin-like electronic system. Here, we describe a skin-like, multi-functional healthcare system, which includes single crystalline silicon nanomembrane based sensors, nanoparticle-integrated non-volatile memory modules, electro-resistive thermal actuators, and drug delivery. Smart prosthetics coupled with therapeutic electronic system would provide new approaches to personalized healthcare.
Design and development of an IBM/VM menu system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cazzola, D.J.
1992-10-01
This report describes a full screen menu system developed using IBM's Interactive System Productivity Facility (ISPF) and the REXX programming language. The software was developed for the 2800 IBM/VM Electrical Computer Aided Design (ECAD) system. The system was developed to deliver electronic drawing definitions to a corporate drawing release system. Although this report documents the status of the menu system when it was retired, the methodologies used and the requirements defined are very applicable to replacement systems.
NASA Astrophysics Data System (ADS)
Boháček, K.; Kozlová, M.; Nejdl, J.; Chaulagain, U.; Horný, V.; Krůs, M.; Ta Phuoc, K.
2018-03-01
The generation of stable electron beams produced by the laser wakefield acceleration mechanism with a few-terawatt laser system (600 mJ, 50 fs) in a supersonic synthetic air jet is reported and the requirements necessary to build such a stable electron source are experimentally investigated in conditions near the bubble regime threshold. The resulting electron beams have stable energies of (17.4 ± 1.1) MeV and an energy spread of (13.5 ± 1.5) MeV (FWHM), which has been achieved by optimizing the properties of the supersonic gas jet target for the given laser system. Due to the availability of few-terawatt laser systems in many laboratories around the world these stable electron beams open possibilities for applications of this type of particle source.
Flight control electronics reliability/maintenance study
NASA Technical Reports Server (NTRS)
Dade, W. W.; Edwards, R. H.; Katt, G. T.; Mcclellan, K. L.; Shomber, H. A.
1977-01-01
Collection and analysis of data are reported that concern the reliability and maintenance experience of flight control system electronics currently in use on passenger carrying jet aircraft. Two airlines B-747 airplane fleets were analyzed to assess the component reliability, system functional reliability, and achieved availability of the CAT II configuration flight control system. Also assessed were the costs generated by this system in the categories of spare equipment, schedule irregularity, and line and shop maintenance. The results indicate that although there is a marked difference in the geographic location and route pattern between the airlines studied, there is a close similarity in the reliability and the maintenance costs associated with the flight control electronics.
Electronic recording and reporting system for tuberculosis in China: experience and opportunities.
Huang, Fei; Cheng, ShiMing; Du, Xin; Chen, Wei; Scano, Fabio; Falzon, Dennis; Wang, Lixia
2014-01-01
Tuberculosis (TB) surveillance in China is organized through a nationwide network of about 3200 hospitals and health facilities. In 2005, an electronic Tuberculosis Information Management System (TBIMS) started to be phased in to replace paper recording. The TBIMS collects key information on TB cases notified in TB care facilities, and exchanges real-time data with the Infectious Disease Reporting System, which covers the country's 37 notifiable diseases. The system is accessible to authorized users at every level of the TB network through a password-protected website. By 2009 the TBIMS achieved nationwide coverage. Completeness of data on patient bacteriological end points improved remarkably over time. Data on about a million active TB cases, including drug-resistant TB, are included each year. The sheer scale of the data handling and the intricate functions that the China TBIMS performs makes it stand apart from the electronic information systems for TB adopted in other countries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagen, K.G.
1975-06-01
The report describes the development status of a heart assist system driven by a nuclear fueled, electronically controlled vapor cycle engine termed the tidal regenerator engine (TRE). The TRE pressurization (typically from 5-160 psia) is controlled by a torque motor coupled to a displacer. The electrical power for the sensor, electronic logic and actuator is provided by a thermoelectric module interposed between the engine superheater and boiler. The TRE is direct coupled to an assist blood pump which also acts as a blood-cooled heat exchanger, pressure-volume transformer and sensor for the electronic logic. Engine efficiencies in excess of 14% havemore » been demonstrated. Efficiency values as high as 13% have been achieved to date.« less
ERIC Educational Resources Information Center
Shalvoy, Mary Lee
1985-01-01
Describes range of options and features in gradebook programs and reviews most popular and readily available software for organizing, calculating, and updating grades: Master Grades, EA Gradebook, Gradeaid, Grader, Graphic Gradebook, Classic Plus Gradekeeping System, Records, Gradecalc, Grade Master, Report Card, Electronic Gradebook for…
Final Report Program Plan for Search and Rescue Electronics Alerting and Locating System
DOT National Transportation Integrated Search
1974-02-01
This study investigates the requirements that exist for electronic devices for alerting and locating distress incidents and presents a plan for acquiring an adequate capability. Data are provided that bound the problem. Possible alternatives are exam...
LASER Tech Briefs, September 1993. Volume 1, No. 1
NASA Technical Reports Server (NTRS)
Schnirring, Bill (Editor)
1993-01-01
This edition of LASER Tech briefs contains a feature on photonics. The other topics include: Electronic Components and Circuits. Electronic Systems, Physical Sciences, Materials, Computer Programs, Mechanics, Machinery, Fabrication Technology, Mathematics and Information Sciences, Life Sciences and books and reports.
NASA Tech Briefs, December 1995. Volume 19, No. 12
NASA Technical Reports Server (NTRS)
1995-01-01
Topics include: a special focus section on Bio/Medical technology, electronic components and circuits, electronic systems, physical sciences, materials, computer programs, mechanics, machinery, manufacturing/fabrication, mathematics and information sciences, book and reports, and a special section on Laser Tech Briefs.
Automated Reporting of Trainee Metrics Using Electronic Clinical Systems.
Levin, Jonathan C; Hron, Jonathan
2017-06-01
The Accreditation Council for Graduate Medical Education has called for increased emphasis on reporting objective performance measures to trainees and programs. However, reporting of objective measures, including clinical volume, is largely omitted from training programs. To use automated electronic medical systems at a tertiary pediatric care hospital to create a dashboard that reports objective trainee and program metrics, including clinical volume and diagnoses in a pediatrics residency. We queried an enterprise data warehouse that aggregates data daily from multiple hospital systems to identify patient encounters during which senior pediatrics residents at Boston Children's Hospital had entered documentation over a 9-month period. From this query, we created a filterable dashboard to display clinical volume and diagnosis data by individual resident and in aggregate. A total of 44 of 45 senior residents (98%) in the program were included in analysis. We identified 12 198 patient encounters during which a senior pediatrics resident had entered documentation; these included a median of 332 inpatient encounters per resident, 122 emergency department encounters, and 84 outpatient encounters. The most common diagnoses stratified by clinical site were: inpatient - dehydration (median = 61); emergency department - long-term/current drug therapy (median = 16); and outpatient - encounter for immunization (median = 48). We used electronic health record systems to generate performance dashboards for trainees in a pediatrics residency across different sites of care with reported volume by diagnosis. Our dashboards provide feedback to program leadership regarding individual and aggregate trainee experience and allow individual trainees to compare their clinical exposure to peers.
Adverse drug event reporting systems: a systematic review
Peddie, David; Wickham, Maeve E.; Badke, Katherin; Small, Serena S.; Doyle‐Waters, Mary M.; Balka, Ellen; Hohl, Corinne M.
2016-01-01
Aim Adverse drug events (ADEs) are harmful and unintended consequences of medications. Their reporting is essential for drug safety monitoring and research, but it has not been standardized internationally. Our aim was to synthesize information about the type and variety of data collected within ADE reporting systems. Methods We developed a systematic search strategy, applied it to four electronic databases, and completed an electronic grey literature search. Two authors reviewed titles and abstracts, and all eligible full‐texts. We extracted data using a standardized form, and discussed disagreements until reaching consensus. We synthesized data by collapsing data elements, eliminating duplicate fields and identifying relationships between reporting concepts and data fields using visual analysis software. Results We identified 108 ADE reporting systems containing 1782 unique data fields. We mapped them to 33 reporting concepts describing patient information, the ADE, concomitant and suspect drugs, and the reporter. While reporting concepts were fairly consistent, we found variability in data fields and corresponding response options. Few systems clarified the terminology used, and many used multiple drug and disease dictionaries such as the Medical Dictionary for Regulatory Activities (MedDRA). Conclusion We found substantial variability in the data fields used to report ADEs, limiting the comparability of ADE data collected using different reporting systems, and undermining efforts to aggregate data across cohorts. The development of a common standardized data set that can be evaluated with regard to data quality, comparability and reporting rates is likely to optimize ADE data and drug safety surveillance. PMID:27016266
Adverse drug event reporting systems: a systematic review.
Bailey, Chantelle; Peddie, David; Wickham, Maeve E; Badke, Katherin; Small, Serena S; Doyle-Waters, Mary M; Balka, Ellen; Hohl, Corinne M
2016-07-01
Adverse drug events (ADEs) are harmful and unintended consequences of medications. Their reporting is essential for drug safety monitoring and research, but it has not been standardized internationally. Our aim was to synthesize information about the type and variety of data collected within ADE reporting systems. We developed a systematic search strategy, applied it to four electronic databases, and completed an electronic grey literature search. Two authors reviewed titles and abstracts, and all eligible full-texts. We extracted data using a standardized form, and discussed disagreements until reaching consensus. We synthesized data by collapsing data elements, eliminating duplicate fields and identifying relationships between reporting concepts and data fields using visual analysis software. We identified 108 ADE reporting systems containing 1782 unique data fields. We mapped them to 33 reporting concepts describing patient information, the ADE, concomitant and suspect drugs, and the reporter. While reporting concepts were fairly consistent, we found variability in data fields and corresponding response options. Few systems clarified the terminology used, and many used multiple drug and disease dictionaries such as the Medical Dictionary for Regulatory Activities (MedDRA). We found substantial variability in the data fields used to report ADEs, limiting the comparability of ADE data collected using different reporting systems, and undermining efforts to aggregate data across cohorts. The development of a common standardized data set that can be evaluated with regard to data quality, comparability and reporting rates is likely to optimize ADE data and drug safety surveillance. © 2016 The British Pharmacological Society.
Nayor, Jennifer; Borges, Lawrence F; Goryachev, Sergey; Gainer, Vivian S; Saltzman, John R
2018-07-01
ADR is a widely used colonoscopy quality indicator. Calculation of ADR is labor-intensive and cumbersome using current electronic medical databases. Natural language processing (NLP) is a method used to extract meaning from unstructured or free text data. (1) To develop and validate an accurate automated process for calculation of adenoma detection rate (ADR) and serrated polyp detection rate (SDR) on data stored in widely used electronic health record systems, specifically Epic electronic health record system, Provation ® endoscopy reporting system, and Sunquest PowerPath pathology reporting system. Screening colonoscopies performed between June 2010 and August 2015 were identified using the Provation ® reporting tool. An NLP pipeline was developed to identify adenomas and sessile serrated polyps (SSPs) on pathology reports corresponding to these colonoscopy reports. The pipeline was validated using a manual search. Precision, recall, and effectiveness of the natural language processing pipeline were calculated. ADR and SDR were then calculated. We identified 8032 screening colonoscopies that were linked to 3821 pathology reports (47.6%). The NLP pipeline had an accuracy of 100% for adenomas and 100% for SSPs. Mean total ADR was 29.3% (range 14.7-53.3%); mean male ADR was 35.7% (range 19.7-62.9%); and mean female ADR was 24.9% (range 9.1-51.0%). Mean total SDR was 4.0% (0-9.6%). We developed and validated an NLP pipeline that accurately and automatically calculates ADRs and SDRs using data stored in Epic, Provation ® and Sunquest PowerPath. This NLP pipeline can be used to evaluate colonoscopy quality parameters at both individual and practice levels.
Blaya, J A; Shin, S S; Yale, G; Suarez, C; Asencios, L; Contreras, C; Rodriguez, P; Kim, J; Cegielski, P; Fraser, H S F
2010-08-01
To evaluate the impact of the e-Chasqui laboratory information system in reducing reporting errors compared to the current paper system. Cluster randomized controlled trial in 76 health centers (HCs) between 2004 and 2008. Baseline data were collected every 4 months for 12 months. HCs were then randomly assigned to intervention (e-Chasqui) or control (paper). Further data were collected for the same months the following year. Comparisons were made between intervention and control HCs, and before and after the intervention. Intervention HCs had respectively 82% and 87% fewer errors in reporting results for drug susceptibility tests (2.1% vs. 11.9%, P = 0.001, OR 0.17, 95%CI 0.09-0.31) and cultures (2.0% vs. 15.1%, P < 0.001, OR 0.13, 95%CI 0.07-0.24), than control HCs. Preventing missing results through online viewing accounted for at least 72% of all errors. e-Chasqui users sent on average three electronic error reports per week to the laboratories. e-Chasqui reduced the number of missing laboratory results at point-of-care health centers. Clinical users confirmed viewing electronic results not available on paper. Reporting errors to the laboratory using e-Chasqui promoted continuous quality improvement. The e-Chasqui laboratory information system is an important part of laboratory infrastructure improvements to support multidrug-resistant tuberculosis care in Peru.
Electronic inhomogeneity in a Kondo lattice
Bauer, E. D.; Yang, Yi-feng; Capan, C.; Urbano, R. R.; Miclea, C. F.; Sakai, H.; Ronning, F.; Graf, M. J.; Balatsky, A. V.; Movshovich, R.; Bianchi, A. D.; Reyes, A. P.; Kuhns, P. L.; Thompson, J. D.; Fisk, Z.
2011-01-01
Inhomogeneous electronic states resulting from entangled spin, charge, and lattice degrees of freedom are hallmarks of strongly correlated electron materials; such behavior has been observed in many classes of d-electron materials, including the high-Tc copper-oxide superconductors, manganites, and most recently the iron–pnictide superconductors. The complexity generated by competing phases in these materials constitutes a considerable theoretical challenge—one that still defies a complete description. Here, we report a manifestation of electronic inhomogeneity in a strongly correlated f-electron system, using CeCoIn5 as an example. A thermodynamic analysis of its superconductivity, combined with nuclear quadrupole resonance measurements, shows that nonmagnetic impurities (Y, La, Yb, Th, Hg, and Sn) locally suppress unconventional superconductivity, generating an inhomogeneous electronic “Swiss cheese” due to disrupted periodicity of the Kondo lattice. Our analysis may be generalized to include related systems, suggesting that electronic inhomogeneity should be considered broadly in Kondo lattice materials.
Test results: Halon 1301 versus water sprinkler fire protection for essential electronic equipment
NASA Astrophysics Data System (ADS)
Reichelt, E. F.; Walker, J. L.; Vickers, R. N.; Kwan, A. J.
1982-07-01
This report describes results of testing two contending extinguishants, Halon 1301 and water, for fire protection of essential electronic equipment. A series of controlled fires in a facility housing an operational electronic data processing system sought to establish immediate and long term effects of exposure of sensitive electronic equipment and stored data to fire extinguishment atmospheres. Test results lead to the conclusion that Halon 1301 is superior to water as an extinguishant for fires occurring in essential electronic equipment installations.
An electromechanical material testing system for in situ electron microscopy and applications.
Zhu, Yong; Espinosa, Horacio D
2005-10-11
We report the development of a material testing system for in situ electron microscopy (EM) mechanical testing of nanostructures. The testing system consists of an actuator and a load sensor fabricated by means of surface micromachining. This previously undescribed nanoscale material testing system makes possible continuous observation of the specimen deformation and failure with subnanometer resolution, while simultaneously measuring the applied load electronically with nanonewton resolution. This achievement was made possible by the integration of electromechanical and thermomechanical components based on microelectromechanical system technology. The system capabilities are demonstrated by the in situ EM testing of free-standing polysilicon films, metallic nanowires, and carbon nanotubes. In particular, a previously undescribed real-time instrumented in situ transmission EM observation of carbon nanotubes failure under tensile load is presented here.
Prognostics for Electronics Components of Avionics Systems
NASA Technical Reports Server (NTRS)
Celaya, Jose R.; Saha, Bhaskar; Wysocki, Philip F.; Goebel, Kai F.
2009-01-01
Electronics components have and increasingly critical role in avionics systems and for the development of future aircraft systems. Prognostics of such components is becoming a very important research filed as a result of the need to provide aircraft systems with system level health management. This paper reports on a prognostics application for electronics components of avionics systems, in particular, its application to the Isolated Gate Bipolar Transistor (IGBT). The remaining useful life prediction for the IGBT is based on the particle filter framework, leveraging data from an accelerated aging tests on IGBTs. The accelerated aging test provided thermal-electrical overstress by applying thermal cycling to the device. In-situ state monitoring, including measurements of the steady-state voltages and currents, electrical transients, and thermal transients are recorded and used as potential precursors of failure.
Energy Transformation in Molecular Electronic Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasha, Michael
1999-05-17
This laboratory has developed many new ideas and methods in the electronic spectroscopy of molecules. This report covers the contract period 1993-1995. A number of the projects were completed in 1996, and those papers are included in the report. The DOE contract was terminated at the end of 1995 owing to a reorganizational change eliminating nationally the projects under the Office of Health and Environmental Research, U. S. Department of Energy.
RLE progress report no. 133, 1 January - 31 December 1990
NASA Technical Reports Server (NTRS)
Allen, Jonathan; Kleppner, Daniel; Ziegler, Mary J. (Editor); Passero, Barbara (Editor)
1990-01-01
Activities of the Research Laboratory of Electronics at MIT are summarized. NASA-sponsored research in the area of synthetic aperture radar image interpretation and simulation is described. Other government-sponsored and industry-sponsored studies are also described which address the following topics: microwave and millimeter wave integrated circuits, high-speed integrated circuit interconnects, Instrument Landing System/Microwave Landing System frequency management assessment, and superconducting electronics.
MIT Lincoln Laboratory 2011 Facts
2011-01-01
currently valid OMB control number. 1. REPORT DATE 2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4. TITLE AND SUBTITLE MIT Lincoln...primary mission areas—space control ; air and missile defense; communication systems; intelligence, surveillance, and reconnaissance systems; advanced...electronics; tactical systems; homeland protection and chemical and biological defense; cyber security; and air traffic control . Two of the
Radio-frequency flexible and stretchable electronics: the need, challenges and opportunities
NASA Astrophysics Data System (ADS)
Jung, Yei Hwan; Seo, Jung-Hun; Zhang, Huilong; Lee, Juhwan; Cho, Sang June; Chang, Tzu-Hsuan; Ma, Zhenqiang
2017-05-01
Successful integration of ultrathin flexible or stretchable systems with new applications, such as medical devices and biodegradable electronics, have intrigued many researchers and industries around the globe to seek materials and processes to create high-performance, non-invasive and cost-effective electronics to match those of state-of-the-art devices. Nevertheless, the crucial concept of transmitting data or power wirelessly for such unconventional devices has been difficult to realize due to limitations of radio-frequency (RF) electronics in individual components that form a wireless circuitry, such as antenna, transmission line, active devices, passive devices etc. To overcome such challenges, these components must be developed in a step-by-step manner, as each component faces a number of different challenges in ultrathin formats. Here, we report on materials and design considerations for fabricating flexible and stretchable electronics systems that operate in the microwave level. High-speed flexible active devices, including cost effective Si-based strained MOSFETs, GaAs-based HBTs and GaN-based HEMTs, performing at multi-gigahertz frequencies are presented. Furthermore, flexible or stretchable passive devices, including capacitors, inductors and transmission lines that are vital parts of a microwave circuitry are also demonstrated. We also present unique applications using the presented flexible or stretchable RF components, including wearable RF electronics and biodegradable RF electronics, which were impossible to achieve using conventional rigid, wafer-based technology. Further opportunities like implantable systems exist utilizing such ultrathin RF components, which are discussed in this report as well.
Mims electron-nuclear double resonance in LiYF4:Ce3+ crystal
NASA Astrophysics Data System (ADS)
Gafurov, M.; Mamin, G.; Kurkin, I.; Orlinskii, S.
2018-05-01
We report the observation of the pulsed electron-nuclear double resonance (ENDOR) spectra from 19F and 7Li nuclei on impurity Ce3+ ions in LiYF4 crystal. The resolved structure from the nearby and remote nuclei in spectra is observed. The outcome shows that LiYF4:Ce3+ system can be exploited as a convenient matrix for performing spin manipulations and adjusting quantum computation protocols while ENDOR technique is usable for the investigation of electron-nuclear interaction with all the nuclei of the system.
FY2012 Advanced Power Electronics and Electric Motors Annual Progress Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, Susan A.
The Advanced Power Electronics and Electric Motors (APEEM) program within the DOE Vehicle Technologies Office (VTO) provides support and guidance for many cutting-edge automotive technologies now under development. Research is focused on developing revolutionary new power electronics (PE), electric motor (EM), thermal management, and traction drive system technologies that will leapfrog current on-the-road technologies. The research and development is also aimed at achieving a greater understanding of and improvements in the way the various new components of tomorrow's automobiles will function as a unified system to improve fuel efficiency.
NASA Tech Briefs, October 1998. Volume 22, No. 10
NASA Technical Reports Server (NTRS)
1998-01-01
Topics include: special coverage sections on sensors/imaging and mechanical technology, and sections on electronic components and circuits, electronic systems, software, materials, machinery/automation, manufacturing/fabrication, physical sciences, information sciences, book and reports, and a special section of Photonics Tech Briefs.
Design and development of an IBM/VM menu system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cazzola, D.J.
1992-10-01
This report describes a full screen menu system developed using IBM`s Interactive System Productivity Facility (ISPF) and the REXX programming language. The software was developed for the 2800 IBM/VM Electrical Computer Aided Design (ECAD) system. The system was developed to deliver electronic drawing definitions to a corporate drawing release system. Although this report documents the status of the menu system when it was retired, the methodologies used and the requirements defined are very applicable to replacement systems.
NASA Tech Briefs, March 1998. Volume 22, No. 3
NASA Technical Reports Server (NTRS)
1998-01-01
Topics include: special coverage of computer aided design and engineering, electronic components and circuits, electronic systems, physical sciences, materials, computer software, special coverage on mechanical technology, machinery/automation, manufacturing/fabrication, mathematics and information sciences, book and reports, and a special section of Electronics Tech Briefs. Profiles of the exhibitors at the National Design Engineering show are also included in this issue.
Black, Corri; Tagiyeva-Milne, Nara; Helms, Peter; Moir, Dorothy
2015-10-01
A systematic review of the literature published in English over 10 years was undertaken in order to describe the use of electronic healthcare data in the identification of potential adverse drug reactions (ADRs) in children. MEDLINE and EMBASE were searched using MESH headings and text words. Titles, keywords and abstracts were checked for age <18 years, potential ADRs and electronic healthcare data. Information extracted included age, data source, pharmacovigilance method, medicines and ADRs. Studies were quality assessed. From 14 804 titles, 314 had a full text review and 71 were included in the final review. Fifty were published in North America, 10 in Scandinavia. Study size ranged from less than 1000 children to more than 10 million. Sixty per cent of studies used data from one source. Comparative observational studies were most commonly reported (66.2%) with 15% using passive surveillance. Electronic healthcare data set linkage and the quality of the data source were poorly reported. ADRs were classified using the International Classification of Disease (ICD10). Multi-system reactions were most commonly studied, followed by central nervous system and mental and behavioural disorders. Vaccines were most frequently prescribed followed by corticosteroids, general anaesthetics and antidepressants. Routine electronic healthcare records were increasingly reported to be used for pharmacovigilance in children. This growing and important health protection activity could be enhanced by consistent reporting of studies to improve the identification, interpretation and generalizability of the evidence base. © 2015 The British Pharmacological Society.
Filatov, Michael; Liu, Fang; Kim, Kwang S.; ...
2016-12-22
Here, the spin-restricted ensemble-referenced Kohn-Sham (REKS) method is based on an ensemble representation of the density and is capable of correctly describing the non-dynamic electron correlation stemming from (near-)degeneracy of several electronic configurations. The existing REKS methodology describes systems with two electrons in two fractionally occupied orbitals. In this work, the REKS methodology is extended to treat systems with four fractionally occupied orbitals accommodating four electrons and self-consistent implementation of the REKS(4,4) method with simultaneous optimization of the orbitals and their fractional occupation numbers is reported. The new method is applied to a number of molecular systems where simultaneous dissociationmore » of several chemical bonds takes place, as well as to the singlet ground states of organic tetraradicals 2,4-didehydrometaxylylene and 1,4,6,9-spiro[4.4]nonatetrayl.« less
NASA Astrophysics Data System (ADS)
Yeh, Shu-Hao; Engel, Gregory S.; Kais, Sabre
Recently it has been suggested that the long-lived coherences in some photosynthetic pigment-protein systems, such as the Fenna-Matthews-Olson complex, could be attributed to the mixing of the pigments' electronic and vibrational degrees of freedom. In order to verify whether this is the case and to understand its underlying mechanism, a theoretical model capable of including both the electronic excitations and intramolecular vibrational modes of the pigments is necessary. Our model simultaneously considers the electronic and vibrational degrees of freedom, treating the system-environment interactions non-perturbatively by implementing the hierarchical equations of motion approach. Here we report the simulated two-dimensional electronic spectra of vibronically coupled molecular dimers to demonstrate how the electronic coherence lifetimes can be extended by borrowing the lifetime from the vibrational coherences. Funded by Qatar National Research Fund and Qatar Environment and Energy Research Institute.
Observation of the quantum Hall effect in δ-doped SrTiO3
Matsubara, Y.; Takahashi, K. S.; Bahramy, M. S.; Kozuka, Y.; Maryenko, D.; Falson, J.; Tsukazaki, A.; Tokura, Y.; Kawasaki, M.
2016-01-01
The quantum Hall effect is a macroscopic quantum phenomenon in a two-dimensional electron system. The two-dimensional electron system in SrTiO3 has sparked a great deal of interest, mainly because of the strong electron correlation effects expected from the 3d orbitals. Here we report the observation of the quantum Hall effect in a dilute La-doped SrTiO3-two-dimensional electron system, fabricated by metal organic molecular-beam epitaxy. The quantized Hall plateaus are found to be solely stemming from the low Landau levels with even integer-filling factors, ν=4 and 6 without any contribution from odd ν's. For ν=4, the corresponding plateau disappears on decreasing the carrier density. Such peculiar behaviours are proposed to be due to the crossing between the Landau levels originating from the two subbands composed of d orbitals with different effective masses. Our findings pave a way to explore unprecedented quantum phenomena in d-electron systems. PMID:27228903
41 CFR 102-192.100 - How do we submit our annual mail management report to GSA?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION... annual reports using the GSA web-based Electronic Performance Support Tool (EPST). Agency mail managers...
James, Matthew T; Hobson, Charles E; Darmon, Michael; Mohan, Sumit; Hudson, Darren; Goldstein, Stuart L; Ronco, Claudio; Kellum, John A; Bagshaw, Sean M
2016-01-01
Electronic medical records and clinical information systems are increasingly used in hospitals and can be leveraged to improve recognition and care for acute kidney injury. This Acute Dialysis Quality Initiative (ADQI) workgroup was convened to develop consensus around principles for the design of automated AKI detection systems to produce real-time AKI alerts using electronic systems. AKI alerts were recognized by the workgroup as an opportunity to prompt earlier clinical evaluation, further testing and ultimately intervention, rather than as a diagnostic label. Workgroup members agreed with designing AKI alert systems to align with the existing KDIGO classification system, but recommended future work to further refine the appropriateness of AKI alerts and to link these alerts to actionable recommendations for AKI care. The consensus statements developed in this review can be used as a roadmap for development of future electronic applications for automated detection and reporting of AKI.
Commissioning and Early Operation Experience of the NSLS-II Storage Ring RF System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, F.; Rose, J.; Cupolo, J.
2015-05-03
The National Synchrotron Light Source II (NSLS-II) is a 3 GeV electron X-ray user facility commissioned in 2014. The storage ring RF system, essential for replenishing energy loss per turn of the electrons, consists of digital low level RF controllers, 310 kW CW klystron transmitters, CESR-B type superconducting cavities, as well as a supporting cryogenic system. Here we will report on RF commissioning and early operation experience of the system for beam current up to 200mA.
Interactive Voice/Web Response System in clinical research
Ruikar, Vrishabhsagar
2016-01-01
Emerging technologies in computer and telecommunication industry has eased the access to computer through telephone. An Interactive Voice/Web Response System (IxRS) is one of the user friendly systems for end users, with complex and tailored programs at its backend. The backend programs are specially tailored for easy understanding of users. Clinical research industry has experienced revolution in methodologies of data capture with time. Different systems have evolved toward emerging modern technologies and tools in couple of decades from past, for example, Electronic Data Capture, IxRS, electronic patient reported outcomes, etc. PMID:26952178
Interactive Voice/Web Response System in clinical research.
Ruikar, Vrishabhsagar
2016-01-01
Emerging technologies in computer and telecommunication industry has eased the access to computer through telephone. An Interactive Voice/Web Response System (IxRS) is one of the user friendly systems for end users, with complex and tailored programs at its backend. The backend programs are specially tailored for easy understanding of users. Clinical research industry has experienced revolution in methodologies of data capture with time. Different systems have evolved toward emerging modern technologies and tools in couple of decades from past, for example, Electronic Data Capture, IxRS, electronic patient reported outcomes, etc.
DOT National Transportation Integrated Search
1999-07-01
This report presents an examination of the process used in preparing electronic credentials for commercial vehicle operations in Kentucky Maryland, and Virginia. It describes the experience of using the Commercial Vehicle Information Systems & Networ...
Intense positron beam as a source for production of electron-positron plasma
NASA Astrophysics Data System (ADS)
Stoneking, M. R.; Horn-Stanja, J.; Stenson, E. V.; Pedersen, T. Sunn; Saitoh, H.; Hergenhahn, U.; Niemann, H.; Paschkowski, N.; Hugenschmidt, C.; Piochacz, C.
2016-10-01
We aim to produce magnetically confined, short Debye length electron-positron plasma and test predicted properties for such systems. A first challenge is obtaining large numbers of positrons; a table-top experiment (system size 5 cm) with a temperature less than 5 eV requires about 1010 positrons to have more than 10 Debye lengths in the system. The NEPOMUC facility at the FRM II research reactor in Germany is one of the world's most intense positron sources. We report on characterization (using a retarding field energy analyzer with magnetic field gradient) of the NEPOMUC beam as delivered to the open beam port at various beam energies and in both the re-moderated and primary beam configurations in order to design optimal trapping (and accumulation) schemes for production of electron-positron plasma. The intensity of the re-moderated (primary) beam is in the range 2 -3 x 107 /s (1 - 5 x 108 /s). The re-moderated beam is currently the most promising for direct injection and confinement experiments; it has a parallel energy spread of 15 - 35% and the transverse energy spread is 6 - 15% of the parallel energy. We report on the implications for injection and trapping in a dipole magnetic field as well as plans for beam development, in situ re-moderation, and accumulation. We also report results demonstrating a difference in phosphor luminescent response to low energy positrons versus electrons.
Fault-Tolerant VLSI Design Assessments for Advanced Avionics Department. Literature Review. Phase 1
1982-02-05
negative sense. Another facet of the literature review is to acquaint the researchers with the immense literature base for electronic technology applicable ...Riley, "Special Report: Semiconductor Memories are Tested Over Data-Storage Application ", Electronics, vol. 46, August 19. G. Luecke, J. P. Mize and W...Design and Evaluation of Self-Checking Systems", Report Submitted to the Mathematical and Information Science Division of the Office of Naval
Observation of orbital order in the half-filled 4 f Gd compound
Jang, H.; Kang, B. Y.; Cho, B. K.; ...
2016-11-18
Half-filled electron systems, even with the maximized spin angular moment, have been given little attention because of their zero-orbital angular moment according to Hund’s rule. Nevertheless, there are several measurements that show evidence of a nonzero orbital moment as well as spin-orbit coupling. Here we report for the first time the orbital order in a half-filled 4f-electron system GdB 4, using the resonant soft x-ray scattering at Gd M 4,5-edges. Furthermore, we discovered that the development of this orbital order is strongly coupled with the antiferromagnetic spin order. Lastly, these results clearly demonstrate that even in half-filled electron systems themore » orbital angular moment can be an important parameter to describe material properties, and may provide significant opportunities for tailoring new correlated electron systems.« less
Observation of orbital order in the half-filled 4 f Gd compound
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jang, H.; Kang, B. Y.; Cho, B. K.
Half-filled electron systems, even with the maximized spin angular moment, have been given little attention because of their zero-orbital angular moment according to Hund’s rule. Nevertheless, there are several measurements that show evidence of a nonzero orbital moment as well as spin-orbit coupling. Here we report for the first time the orbital order in a half-filled 4f-electron system GdB 4, using the resonant soft x-ray scattering at Gd M 4,5-edges. Furthermore, we discovered that the development of this orbital order is strongly coupled with the antiferromagnetic spin order. Lastly, these results clearly demonstrate that even in half-filled electron systems themore » orbital angular moment can be an important parameter to describe material properties, and may provide significant opportunities for tailoring new correlated electron systems.« less
Data Quality Monitoring System for New GEM Muon Detectors for the CMS Experiment Upgrade
NASA Astrophysics Data System (ADS)
King, Robert; CMS Muon Group Team
2017-01-01
The Gas Electron Multiplier (GEM) detectors are novel detectors designed to improve the muon trigger and tracking performance in CMS experiment for the high luminosity upgrade of the LHC. Partial installation of GEM detectors is planned during the 2016-2017 technical stop. Before the GEM system is installed underground, its data acquisition (DAQ) electronics must be thoroughly tested. The DAQ system includes several commercial and custom-built electronic boards running custom firmware. The front-end electronics are radiation-hard and communicate via optical fibers. The data quality monitoring (DQM) software framework has been designed to provide online verification of the integrity of the data produced by the detector electronics, and to promptly identify potential hardware or firmware malfunctions in the system. Local hits reconstruction and clustering algorithms allow quality control of the data produced by each GEM chamber. Once the new detectors are installed, the DQM will monitor the stability and performance of the system during normal data-taking operations. We discuss the design of the DQM system, the software being developed to read out and process the detector data, and the methods used to identify and report hardware and firmware malfunctions of the system.
2014-12-10
AFRL-OSR-VA-TR-2014-0359 Fundamental Materials Studies for Advanced High Power Microwave and Terahertz John Booske UNIVERSITY OF WISCONSIN SYSTEM...12-2014 Final Technical Performance Report October 1, 2011 - September 30, 2014 Fundamental Materials Studies for Advanced High Power Microwave and...emission-barrier scandate cathodes and identify related, alternative cathode materials systems for advanced vacuum electronic cathodes for high power THz
Dixon, Brian E; McGowan, Julie J; Grannis, Shaun J
2011-01-01
There is increasing interest in leveraging electronic health data across disparate sources for a variety of uses. A fallacy often held by data consumers is that clinical data quality is homogeneous across sources. We examined one attribute of data quality, completeness, in the context of electronic laboratory reporting of notifiable disease information. We evaluated 7.5 million laboratory reports from clinical information systems for their completeness with respect to data needed for public health reporting processes. We also examined the impact of health information exchange (HIE) enhancement methods that attempt to improve completeness. The laboratory data were heterogeneous in their completeness. Fields identifying the patient and test results were usually complete. Fields containing patient demographics, patient contact information, and provider contact information were suboptimal. Data processed by the HIE were often more complete, suggesting that HIEs can support improvements to existing public health reporting processes.
Laboratory and Field Testing of NYCTA Power Frequency Track Circuits
DOT National Transportation Integrated Search
1986-02-01
This report addresses the possible electromagnetic interference between the electronic AC propulsion control systems and the signaling and train control systems. The potential exists for AC-drive propulsion systems to cause EMI that can adversely aff...
Duregger, Katharina; Hayn, Dieter; Nitzlnader, Michael; Kropf, Martin; Falgenhauer, Markus; Ladenstein, Ruth; Schreier, Günter
2016-01-01
Electronic Patient Reported Outcomes (ePRO) gathered using telemonitoring solutions might be a valuable source of information in rare cancer research. The objective of this paper was to develop a concept and implement a prototype for introducing ePRO into the existing neuroblastoma research network by applying Near Field Communication and mobile technology. For physicians, an application was developed for registering patients within the research network and providing patients with an ID card and a PIN for authentication when transmitting telemonitoring data to the Electronic Data Capture system OpenClinica. For patients, a previously developed telemonitoring system was extended by a Simple Object Access Protocol (SOAP) interface for transmitting nine different health parameters and toxicities. The concept was fully implemented on the front-end side. The developed application for physicians was prototypically implemented and the mobile application of the telemonitoring system was successfully connected to OpenClinica. Future work will focus on the implementation of the back-end features.
Electronic medical record in cardiology: a 10-year Italian experience.
Carpeggiani, Clara; Macerata, Alberto; Morales, Maria Aurora
2015-08-01
the aim of this study was to report a ten years experience in the electronic medical record (EMR) use. An estimated 80% of healthcare transactions are still paper-based. an EMR system was built at the end of 1998 in an Italian tertiary care center to achieve total integration among different human and instrumental sources, eliminating paper-based medical records. Physicians and nurses who used EMR system reported their opinions. In particular the hospital activity supported electronically, regarding 4,911 adult patients hospitalized in the 2004- 2008 period, was examined. the final EMR product integrated multimedia document (text, images, signals). EMR presented for the most part advantages and was well adopted by the personnel. Appropriateness evaluation was also possible for some procedures. Some disadvantages were encountered, such as start-up costs, long time required to learn how to use the tool, little to no standardization between systems and the EMR technology. the EMR is a strategic goal for clinical system integration to allow a better health care quality. The advantages of the EMR overcome the disadvantages, yielding a positive return on investment to health care organization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winter, T.G.; Alston, S.G.
The research program of Winter and Alston addresses the fundamental processes of electron transfer, ionization, and excitation in ion-atom, ion-ion, and ion-molecule collisions. Attention is focussed on one- and two-electron systems and, more recently, quasi-one-electron systems whose electron-target-core interaction can be accurately modeled by one-electron potentials. The basic computational approaches can then be taken with few, if any, approximations, and the underlying collisional mechanisms can be more clearly revealed. Winter has focussed on intermediate collision energies (e.g., proton energies for p-He{sup +} collisions on the order of 100 kilo-electron volts), in which many electron states are strongly coupled during themore » collision and a coupled-state approach, such as a coupled-Sturmian-pseudostate approach, is appropriate. Alston has concentrated on higher collision energies (million electron-volt energies), or asymmetric collision systems, for which the coupling of the projectile is weaker with, however, many more target states being coupled together so that high-order perturbation theory is essential. Several calculations by Winter and Alston are described, as set forth in the original proposal.« less
Radiation studies of optical and electronic components used in astronomical satellite studies
NASA Technical Reports Server (NTRS)
Becher, J.; Kernell, R. L.
1981-01-01
The synchronous orbit of the IUE carries the satellite through Earth's outer electron belt. A 40 mCi Sr90 source was used to simulate these electrons. A 5 mCi source of Co60 was used to simulate bremmstrahlung. A 10 MeV electron Linac and a 1.7 MeV electron Van de Graaf wer used to investigate the energy dependence of radiation effects and to perform radiations at a high flux rate. A 100 MeV proton cyclotron was used to simulate cosmic rays. Results are presented for three instrument systems of the IUE and measurements for specific components are reported. The three instrument systems were the ultraviolet converter, the fine error sensor (FES), and the SEC vidicon camera tube. The components were optical glasses, electronic components, silicon photodiodes, and UV window materials.
PREVAIL-EPL alpha tool electron optics subsystem
NASA Astrophysics Data System (ADS)
Pfeiffer, Hans C.; Dhaliwal, Rajinder S.; Golladay, Steven D.; Doran, Samuel K.; Gordon, Michael S.; Kendall, Rodney A.; Lieberman, Jon E.; Pinckney, David J.; Quickle, Robert J.; Robinson, Christopher F.; Rockrohr, James D.; Stickel, Werner; Tressler, Eileen V.
2001-08-01
The IBM/Nikon alliance is continuing pursuit of an EPL stepper alpha tool based on the PREVAIL technology. This paper provides a status report of the alliance activity with particular focus on the Electron Optical Subsystem developed at IBM. We have previously reported on design features of the PREVAIL alpha system. The new state-of-the-art e-beam lithography concepts have since been reduced to practice and turned into functional building blocks of a production level lithography tool. The electron optical alpha tool subsystem has been designed, build, assembled and tested at IBM's Semiconductor Research and Development Center (SRDC) in East Fishkill, New York. After demonstrating subsystem functionality, the electron optical column and all associated control electronics hardware and software have been shipped during January 2001 to Nikon's facility in Kumagaya, Japan, for integration into the Nikon commercial e-beam stepper alpha tool. Early pre-shipment results obtained with this electron optical subsystem are presented.
Three axis electronic flight motion simulator real time control system design and implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Zhiyuan; Miao, Zhonghua, E-mail: zhonghua-miao@163.com; Wang, Xiaohua
2014-12-15
A three axis electronic flight motion simulator is reported in this paper including the modelling, the controller design as well as the hardware implementation. This flight motion simulator could be used for inertial navigation test and high precision inertial navigation system with good dynamic and static performances. A real time control system is designed, several control system implementation problems were solved including time unification with parallel port interrupt, high speed finding-zero method of rotary inductosyn, zero-crossing management with continuous rotary, etc. Tests were carried out to show the effectiveness of the proposed real time control system.
Three axis electronic flight motion simulator real time control system design and implementation.
Gao, Zhiyuan; Miao, Zhonghua; Wang, Xuyong; Wang, Xiaohua
2014-12-01
A three axis electronic flight motion simulator is reported in this paper including the modelling, the controller design as well as the hardware implementation. This flight motion simulator could be used for inertial navigation test and high precision inertial navigation system with good dynamic and static performances. A real time control system is designed, several control system implementation problems were solved including time unification with parallel port interrupt, high speed finding-zero method of rotary inductosyn, zero-crossing management with continuous rotary, etc. Tests were carried out to show the effectiveness of the proposed real time control system.
SEMIANNUAL REPORT TO THE ATOMIC ENERGY COMMISSION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobson, L.O. ed.
Progress is reported in the following studies: carbohydrate metabolism in human erythrocytes; the development of a system of electron therapy employing a linear electron accelerator and an electromagnetic beann deflector; the capacity of progesterone to inhibit the sodium-retaining influence of aldosterone and desoxycorticosterone; use of tritium-labeled cholesterol in measuring the lability of cholesterol in human atherosclerotic plaques; the capacity of a number of steroid hormone metabelites to provoke fever in man; the failure of human placental tissue homogenates to convent progesterone to estrogens; and tracer studies on enzyme requirements for the incorporation of cytidine triphosphate into ribonucleic acid in amore » mammalian system. (L.H.)« less
DiBiase, Lauren; Fangman, Mary T.; Fleischauer, Aaron T.; Waller, Anna E.; MacDonald, Pia D. M.
2013-01-01
Objectives. We assessed the timeliness, accuracy, and cost of a new electronic disease surveillance system at the local health department level. We describe practices associated with lower cost and better surveillance timeliness and accuracy. Methods. Interviews conducted May through August 2010 with local health department (LHD) staff at a simple random sample of 30 of 100 North Carolina counties provided information on surveillance practices and costs; we used surveillance system data to calculate timeliness and accuracy. We identified LHDs with best timeliness and accuracy and used these categories to compare surveillance practices and costs. Results. Local health departments in the top tertiles for surveillance timeliness and accuracy had a lower cost per case reported than LHDs with lower timeliness and accuracy ($71 and $124 per case reported, respectively; P = .03). Best surveillance practices fell into 2 domains: efficient use of the electronic surveillance system and use of surveillance data for local evaluation and program management. Conclusions. Timely and accurate surveillance can be achieved in the setting of restricted funding experienced by many LHDs. Adopting best surveillance practices may improve both efficiency and public health outcomes. PMID:24134385
Improving Patient Safety With the Military Electronic Health Record
2005-01-01
Consolidated Health Informatics (CHI) project, one of the 24 electronic government ( eGov ) Internet- based technology initiatives supporting the president’s...United States Department of Defense (DoD) has transformed health care delivery in its use of information technology to automate patient data...use throughout the Federal Government . The importance of standards in EHR systems was further recognized in an IOM report, which stated, “Electronic
NASA Astrophysics Data System (ADS)
Nakamura, S.; Endo, M.; Yamamoto, H.; Isshiki, T.; Kimura, N.; Aoki, H.; Nojima, T.; Otani, S.; Kunii, S.
2006-12-01
We report unusual evolution of the conduction-electron state in the localized f electron system CexLa1-xB6 from normal electron state to heavy Fermi liquid (FL) state through local FL and non-FL states with increasing Ce concentration and/or with increasing magnetic field. The effective mass of quasiparticle or the coefficient A of T2 term of resistivity is found to increase divergently near the boundary between FL state and non-FL state. The features of the non-FL state are also different from those of the typical non-FL systems previously observed or theoretically predicted.
NASA Tech Briefs, June 1998. Volume 22, No. 6
NASA Technical Reports Server (NTRS)
1998-01-01
Topics include: special coverage on computer hardware and peripherals, electronic components and circuits, electronic systems, software, materials, mechanics, machinery/automation, manufacturing, physical sciences, information sciences, book and reports, and a special section of Photonics Tech Briefs. and a second special section of Motion Control Tech Briefs
DOT National Transportation Integrated Search
1997-12-01
A prototype miniature electronic cone penetrometer system is developed for road and highway design and construction control. The equipment is implemented in front of the Research Vehicle for Geotechnical In Situ testing and Support (REVEGITS). A cali...
NASA Tech Briefs, October 1999. Volume 23, No. 10
NASA Technical Reports Server (NTRS)
1999-01-01
Topics include: special coverage section on data acquisition and sensors and sections on electronic components and systems, software, materials, mechanics, machinery/automation, manufacturing/fabrication, bio-medical, physical sciences, information sciences, book and reports, and special section of Electronics Tech Briefs and Motion Control Tech briefs
40 CFR 1068.501 - How do I report emission-related defects?
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Electronic control units, aftertreatment devices, fuel-metering components, EGR-system components, crankcase...) AIR POLLUTION CONTROLS GENERAL COMPLIANCE PROVISIONS FOR HIGHWAY, STATIONARY, AND NONROAD PROGRAMS Reporting Defects and Recalling Engines/Equipment § 1068.501 How do I report emission-related defects? This...
40 CFR 1068.501 - How do I report emission-related defects?
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Electronic control units, aftertreatment devices, fuel-metering components, EGR-system components, crankcase...) AIR POLLUTION CONTROLS GENERAL COMPLIANCE PROVISIONS FOR HIGHWAY, STATIONARY, AND NONROAD PROGRAMS Reporting Defects and Recalling Engines/Equipment § 1068.501 How do I report emission-related defects? This...
40 CFR 1068.501 - How do I report emission-related defects?
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Electronic control units, aftertreatment devices, fuel-metering components, EGR-system components, crankcase...) AIR POLLUTION CONTROLS GENERAL COMPLIANCE PROVISIONS FOR HIGHWAY, STATIONARY, AND NONROAD PROGRAMS Reporting Defects and Recalling Engines/Equipment § 1068.501 How do I report emission-related defects? This...
Electronic document distribution: Design of the anonymous FTP Langley Technical Report Server
NASA Technical Reports Server (NTRS)
Nelson, Michael L.; Gottlich, Gretchen L.
1994-01-01
An experimental electronic dissemination project, the Langley Technical Report Server (LTRS), has been undertaken to determine the feasibility of delivering Langley technical reports directly to the desktops of researchers worldwide. During the first six months, over 4700 accesses occurred and over 2400 technical reports were distributed. This usage indicates the high level of interest that researchers have in performing literature searches and retrieving technical reports at their desktops. The initial system was developed with existing resources and technology. The reports are stored as files on an inexpensive UNIX workstation and are accessible over the Internet. This project will serve as a foundation for ongoing projects at other NASA centers that will allow for greater access to NASA technical reports.
Detecting Lyme disease using antibody-functionalized carbon nanotubes
NASA Astrophysics Data System (ADS)
Dailey, Jennifer; Lerner, Mitchell; Goldsmith, Brett; Brisson, Dustin; Johnson, A. T. Charlie
2011-03-01
We combine antibodies for Lyme flagellar protein with carbon nanotube transistors to create an electronic sensor capable of definitive detection of Lyme disease. Over 35,000 cases of Lyme disease are reported in the United States each year, of which more than 23 percent are originally misdiagnosed. Rational design of the coupling of the biological system to the electronic system gives us a flexible sensor platform which we can apply to several biological systems. By coupling these antibodies to carbon nanotubes in particular, we allow for fast, sensitive, highly selective, electronic detection. Unlike antibody or biomarker detection, bacterial protein detection leads to positive identification of both early and late stage bacterial infections, and is easily expandable to environmental monitoring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report contains papers on the following topics: NREN Security Issues: Policies and Technologies; Layer Wars: Protect the Internet with Network Layer Security; Electronic Commission Management; Workflow 2000 - Electronic Document Authorization in Practice; Security Issues of a UNIX PEM Implementation; Implementing Privacy Enhanced Mail on VMS; Distributed Public Key Certificate Management; Protecting the Integrity of Privacy-enhanced Electronic Mail; Practical Authorization in Large Heterogeneous Distributed Systems; Security Issues in the Truffles File System; Issues surrounding the use of Cryptographic Algorithms and Smart Card Applications; Smart Card Augmentation of Kerberos; and An Overview of the Advanced Smart Card Access Control System.more » Selected papers were processed separately for inclusion in the Energy Science and Technology Database.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ling, Hao; Hamilton, Mark F.; Bhalla, Rajan
2013-09-30
Offshore wind energy is a valuable resource that can provide a significant boost to the US renewable energy portfolio. A current constraint to the development of offshore wind farms is the potential for interference to be caused by large wind farms on existing electronic and acoustical equipment such as radar and sonar systems for surveillance, navigation and communications. The US Department of Energy funded this study as an objective assessment of possible interference to various types of equipment operating in the marine environment where offshore wind farms could be installed. The objective of this project was to conduct a baselinemore » evaluation of electromagnetic and acoustical challenges to sea surface, subsurface and airborne electronic systems presented by offshore wind farms. To accomplish this goal, the following tasks were carried out: (1) survey electronic systems that can potentially be impacted by large offshore wind farms, and identify impact assessment studies and research and development activities both within and outside the US, (2) engage key stakeholders to identify their possible concerns and operating requirements, (3) conduct first-principle modeling on the interactions of electromagnetic signals with, and the radiation of underwater acoustic signals from, offshore wind farms to evaluate the effect of such interactions on electronic systems, and (4) provide impact assessments, recommend mitigation methods, prioritize future research directions, and disseminate project findings. This report provides a detailed description of the methodologies used to carry out the study, key findings of the study, and a list of recommendations derived based the findings.« less
76 FR 16002 - Records Schedules; Availability and Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-22
... personnel directories, and on duty and promotion date reports. 15. Department of Justice, Office of the... and system documentation of an electronic information system used to monitor staff productivity and...
Observations of the ratio of low-energy cosmic-ray positrons and electrons during solar quiet times
NASA Technical Reports Server (NTRS)
Hurford, G. J.; Mewaldt, R. A.; Stone, E. C.; Vogt, R. E.
1974-01-01
Simultaneous observations of the quiet-time interplanetary positron and electron spectra between 0.16 and 1.6 MeV are reported. The measurements were made in selected time intervals between October 1, 1972 and February 1, 1973 with the Caltech Electron/Isotope Spectrometer on the IMP-7 satellite. The detector system consists of a stack of 11 silicon surface-barrier detectors surrounded by a plastic scintillator anti-coincidence cup. The method of e+ identification and possible background effects are discussed and upper limits to the 0.16 to 1.6 MeV quiet-time positron flux are reported. During this period positrons amounted to less than 20% of the total 0.16 to 1.6 MeV electron flux.
Hospital Adoption of Health Information Technology to Support Public Health Infrastructure.
Walker, Daniel M; Diana, Mark L
2016-01-01
Health information technology (IT) has the potential to improve the nation's public health infrastructure. In support of this belief, meaningful use incentives include criteria for hospitals to electronically report to immunization registries, as well as to public health agencies for reportable laboratory results and syndromic surveillance. Electronic reporting can facilitate faster and more appropriate public health response. However, it remains unclear the extent that hospitals have adopted IT for public health efforts. To examine hospital adoption of IT for public health and to compare hospitals capable of using and not using public health IT. Cross-sectional design with data from the 2012 American Hospital Association annual survey matched with data from the 2013 American Hospital Association Information Technology Supplement. Multivariate logistic regression was used to compare hospital characteristics. Inverse probability weights were applied to adjust for selection bias because of survey nonresponse. All acute care general hospitals in the United States that matched across the surveys and had complete data available were included in the analytic sample. Three separate outcome measures were used: whether the hospital could electronically report to immunization registries, whether the hospital could send electronic laboratory results, and whether the hospital can participate in syndromic surveillance. A total of 2841 hospitals met the inclusion criteria. Weighted results show that of these hospitals, 62.7% can electronically submit to immunization registries, 56.6% can electronically report laboratory results, and 54.4% can electronically report syndromic surveillance. Adjusted and weighted results from the multivariate analyses show that small, rural hospitals and hospitals without electronic health record systems lag in the adoption of public health IT capabilities. While a majority of hospitals are using public health IT, the infrastructure still has significant room for growth. Differences in hospitals' adoption of public health IT may exacerbate existing health disparities.
Use of electronic monitoring in clinical nursing research.
Ailinger, Rita L; Black, Patricia L; Lima-Garcia, Natalie
2008-05-01
In the past decade, the introduction of electronic monitoring systems for monitoring medication adherence has contributed to the dialog about what works and what does not work in monitoring adherence. The purpose of this article is to describe the use of the Medication Event Monitoring System (MEMS) in a study of patients receiving isoniazid for latent tuberculosis infection. Three case examples from the study illustrate the data that are obtained from the electronic device compared to self-reports and point to the disparities that may occur in electronic monitoring. The strengths and limitations of using the MEMS and ethical issues in utilizing this technology are discussed. Nurses need to be aware of these challenges when using electronic measuring devices to monitor medication adherence in clinical nursing practice and research.
A variational Monte Carlo study of different spin configurations of electron-hole bilayer
NASA Astrophysics Data System (ADS)
Sharma, Rajesh O.; Saini, L. K.; Bahuguna, Bhagwati Prasad
2018-05-01
We report quantum Monte Carlo results for mass-asymmetric electron-hole bilayer (EHBL) system with different-different spin configurations. Particularly, we apply a variational Monte Carlo method to estimate the ground-state energy, condensate fraction and pair-correlations function at fixed density rs = 5 and interlayer distance d = 1 a.u. We find that spin-configuration of EHBL system, which consists of only up-electrons in one layer and down-holes in other i.e. ferromagnetic arrangement within layers and anti-ferromagnetic across the layers, is more stable than the other spin-configurations considered in this study.
Victor, Napoleon John; Gana, Janardhanan; Muraleedharan, Kannoth Manheri
2015-10-12
This report introduces N-methylpyrrolidone hydroperoxide (NMPOOH)/base as an excellent reagent system for hydroxy-directed syn selective epoxidation of electron-deficient olefins, characterized by high diastereoselectivity, short reaction times and remarkable chemoselectivity, especially in presence of oxidatively labile nitrogen or sulfur atoms. NMPOOH also proves efficient in the oxidation of electron-deficient aromatic aldehydes, in the removal of oxazolidinone chiral auxiliary, and in the functionalization of alkenes and alkynes, showing wide application potential. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
FY2011 Advanced Power Electronics and Electric Motors Annual Progress Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, Susan A.
The Advanced Power Electronics and Electric Motors (APEEM) program within the DOE Vehicle Technologies Program (VTP) provides support and guidance for many cutting-edge automotive technologies now under development. Research is focused on developing revolutionary new power electronics (PE), electric motor (EM), thermal management, and traction drive system technologies that will leapfrog current on-the-road technologies. The research and development (R&D) is also aimed at achieving a greater understanding of and improvements in the way the various new components of tomorrow’s automobiles will function as a unified system to improve fuel efficiency.
Definition phase study of the grand tour missions
NASA Technical Reports Server (NTRS)
Simpson, J. A.; Meyer, P.
1972-01-01
The research to define an energetic particle experiment for the OPTGT-MJS missions is reported. The studies reported include: (1) the use of silicon dectectors for low energy, low flux level measurements in the presence of RTG radiation and trapped electrons, (2) high energy proton damage of lithium-drifted and surface barrier silicon detectors, (3) the gas Cerenkov counter, (4) systems for detection of trapped high-energy protons in the presence of trapped electrons, and (5) reliability and redundancy.
Hochgesang, Mindy; Zamudio-Haas, Sophia; Moran, Lissa; Nhampossa, Leopoldo; Packel, Laura; Leslie, Hannah; Richards, Janise; Shade, Starley B
2017-01-01
The rapid scale-up of HIV care and treatment in resource-limited countries requires concurrent, rapid development of health information systems to support quality service delivery. Mozambique, a country with an 11.5% prevalence of HIV, has developed nation-wide patient monitoring systems (PMS) with standardized reporting tools, utilized by all HIV treatment providers in paper or electronic form. Evaluation of the initial implementation of PMS can inform and strengthen future development as the country moves towards a harmonized, sustainable health information system. This assessment was conducted in order to 1) characterize data collection and reporting processes and PMS resources available and 2) provide evidence-based recommendations for harmonization and sustainability of PMS. This baseline assessment of PMS was conducted with eight non-governmental organizations that supported the Ministry of Health to provide 90% of HIV care and treatment in Mozambique. The study team conducted structured and semi-structured surveys at 18 health facilities located in all 11 provinces. Seventy-nine staff were interviewed. Deductive a priori analytic categories guided analysis. Health facilities have implemented paper and electronic monitoring systems with varying success. Where in use, robust electronic PMS facilitate facility-level reporting of required indicators; improve ability to identify patients lost to follow-up; and support facility and patient management. Challenges to implementation of monitoring systems include a lack of national guidelines and norms for patient level HIS, variable system implementation and functionality, and limited human and infrastructure resources to maximize system functionality and information use. This initial assessment supports the need for national guidelines to harmonize, expand, and strengthen HIV-related health information systems. Recommendations may benefit other countries with similar epidemiologic and resource-constrained environments seeking to improve PMS implementation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Electronic structure investigation of neutral titanium oxide molecules TixOy
NASA Astrophysics Data System (ADS)
Jeong, K. S.; Chang, Ch; Sedlmayr, E.; Sülzle, D.
2000-09-01
Electronic and structural properties of energetically low-lying isomers of isolated TixOy (x = 1-6, y = 1-12) molecular systems have been investigated by density functional theoretical methods. A variety of stationary points are thoroughly characterized. We report total cluster energies, equilibrium geometries and harmonic vibrational wavenumbers.
NASA Technical Reports Server (NTRS)
1995-01-01
This issue contains articles with a special focus on Computer-Aided design and engineering amd a research report on the Ames Research Center. Other subjects in this issue are: Electronic Components and Circuits, Electronic Systems, Physical Sciences, Materials, Computer Programs, Mechanics, Machinery, Manufacturing/Fabrication, Mathematics and Information Sciences and Life Sciences
NASA Tech Briefs, October 2000. Volume 24, No. 10
NASA Technical Reports Server (NTRS)
2000-01-01
Topics include: special coverage sections on CAD, CAE, and PDM, and, Composites and Plastics, and sections on electronic components and systems, software, test and measurement, mechanics, manufacturing/fabrication, physical sciences, information sciences, book and reports, and special sections of Electronics Tech Briefs and Motion Control Tech Briefs
Correlating electronic and vibrational motions in charge transfer systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khalil, Munira
2014-06-27
The goal of this research program was to measure coupled electronic and nuclear motions during photoinduced charge transfer processes in transition metal complexes by developing and using novel femtosecond spectroscopies. The scientific highlights and the resulting scientific publications from the DOE supported work are outlined in the technical report.
... on Vital and Health Statistics Annual Reports Health Survey Research Methods Conference Reports from the National Medical Care Utilization and Expenditure Survey Clearinghouse on Health Indexes Statistical Notes for Health ...
75 FR 72737 - Proposed Generic Communications Reporting for Decommissioning Funding Status Reports
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-26
... methods, changing existing methods (for example, changing the terms of contractual obligations or the face... and Management System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Web site, http...
NASA Astrophysics Data System (ADS)
Green, M. A.; Maddern, T.; Brunger, M. J.; Campbell, L.; Cartwright, D. C.; Newell, W. R.; Teubner, P. J. O.
2002-09-01
We report differential cross sections (DCSs) for electron impact excitation of the sum (c1Σ u- + A'3 Δ u + A3 Σ u+) of the three states that constitute the Herzberg pseudocontinuum in O2. These DCSs were measured at seven incident electron energies in the range 9-20 eV and over the scattered electron angular range 10-90°. We note that this represents a far more detailed study than has hitherto previously been reported. In their review on electron-diatomic molecule scattering systems, Brunger and Buckman (Brunger M J and Buckman S J 2002 Phys. Rep. 357 215) clearly identified gaps in our knowledge for electron impact excitation of the Herzberg electronic states. The present study rectifies this situation and, additionally, seeks to stimulate theoreticians to extend their existing integral cross section calculations, for the c1 Σ u-, A'3 Δ u and A3 Σ u+ states, to the DCS-level.
McKaig, Donald; Collins, Christine; Elsaid, Khaled A
2014-09-01
A study was conducted to evaluate the impact of a reengineered approach to electronic error reporting at a 719-bed multidisciplinary urban medical center. The main outcome of interest was the monthly reported medication errors during the preimplementation (20 months) and postimplementation (26 months) phases. An interrupted time series analysis was used to describe baseline errors, immediate change following implementation of the current electronic error-reporting system (e-ERS), and trend of error reporting during postimplementation. Errors were categorized according to severity using the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP) Medication Error Index classifications. Reported errors were further analyzed by reporter and error site. During preimplementation, the monthly reported errors mean was 40.0 (95% confidence interval [CI]: 36.3-43.7). Immediately following e-ERS implementation, monthly reported errors significantly increased by 19.4 errors (95% CI: 8.4-30.5). The change in slope of reported errors trend was estimated at 0.76 (95% CI: 0.07-1.22). Near misses and no-patient-harm errors accounted for 90% of all errors, while errors that caused increased patient monitoring or temporary harm accounted for 9% and 1%, respectively. Nurses were the most frequent reporters, while physicians were more likely to report high-severity errors. Medical care units accounted for approximately half of all reported errors. Following the intervention, there was a significant increase in reporting of prevented errors and errors that reached the patient with no resultant harm. This improvement in reporting was sustained for 26 months and has contributed to designing and implementing quality improvement initiatives to enhance the safety of the medication use process.
The spectrum of the TiCl molecule in the 4200 A region
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, J.G.; Davis, S.P.
1989-09-01
A detailed study of the TiCl spectrum between 4095 and 4200 A was made, and the presence of at least four electronic systems is reported. The wavelengths, wavenumbers, intensities, degradations, and characteristics of the observed band heads in the TiCl spectrum are listed. The J values and the intensities and wavelengths are given for the P and R branches of the four electronic systems. 5 refs.
Surveillance for human Salmonella infections in the United States.
Swaminathan, Bala; Barrett, Timothy J; Fields, Patricia
2006-01-01
Surveillance for human Salmonella infections plays a critical role in understanding and controlling foodborne illness due to Salmonella. Along with its public health partners, the Centers for Disease Control and Prevention (CDC) has several surveillance systems that collect information on Salmonella infections in the United States. The National Salmonella Surveillance System, begun in 1962, receives reports of laboratory-confirmed Salmonella infections through state public health laboratories. Salmonella outbreaks are reported by state and local health departments through the Foodborne Disease Outbreak Reporting System, which became a Web-based, electronic system (eFORS) in 2001. PulseNet facilitates the detection of clusters of Salmonella infections through standardized molecular subtyping (DNA "fingerprinting") of isolates and maintenance of "fingerprint" databases. The National Antimicrobial Resistance Monitoring System for Enteric Bacteria (NARMS) monitors antimicrobial resistance in Salmonella by susceptibility testing of every 20th Salmonella isolate received by state and local public health laboratories. FootNet is an active surveillance system that monitors Salmonella infections in sentinel areas, providing population-based estimates of infection rates. Efforts are underway to electronically link all of the Salmonella surveillance systems at CDC to facilitate optimum use of available data and minimize duplication.
Management of laboratory data and information exchange in the electronic health record.
Wilkerson, Myra L; Henricks, Walter H; Castellani, William J; Whitsitt, Mark S; Sinard, John H
2015-03-01
In the era of the electronic health record, the success of laboratories and pathologists will depend on effective presentation and management of laboratory information, including test orders and results, and effective exchange of data between the laboratory information system and the electronic health record. In this third paper of a series that explores empowerment of pathology in the era of the electronic health record, we review key elements of managing laboratory information within the electronic health record and examine functional issues pertinent to pathologists and laboratories in the exchange of laboratory information between electronic health records and both anatomic and clinical pathology laboratory information systems. Issues with electronic order-entry and results-reporting interfaces are described, and considerations for setting up these interfaces are detailed in tables. The role of the laboratory medical director as mandated by the Clinical Laboratory Improvement Amendments of 1988 and the impacts of discordance between laboratory results and their display in the electronic health record are also discussed.
Implementing an overdose education and naloxone distribution program in a health system.
Devries, Jennifer; Rafie, Sally; Polston, Gregory
To design and implement a health system-wide program increasing provision of take-home naloxone in patients at risk for opioid overdose, with the downstream aim of reducing fatalities. The program includes health care professional education and guidelines, development, and dissemination of patient education materials, electronic health record changes to promote naloxone prescriptions, and availability of naloxone in pharmacies. Academic health system, San Diego, California. University of California, San Diego Health (UCSDH), offers both inpatient and outpatient primary care and specialty services with 563 beds spanning 2 hospitals and 6 pharmacies. UCSDH is part of the University of California health system, and it serves as the county's safety net hospital. In January 2016, a multisite academic health system initiated a system-wide overdose education and naloxone distribution program to prevent opioid overdose and opioid overdose-related deaths. An interdisciplinary, interdepartmental team came together to develop and implement the program. To strengthen institutional support, naloxone prescribing guidelines were developed and approved for the health system. Education on naloxone for physicians, pharmacists, and nurses was provided through departmental trainings, bulletins, and e-mail notifications. Alerts in the electronic health record and preset naloxone orders facilitated co-prescribing of naloxone with opioid prescriptions. Electronic health record reports captured naloxone prescriptions ordered. Summary reports on the electronic health record measured naloxone reminder alerts and response rates. Since the start of the program, the health system has trained 252 physicians, pharmacists, and nurses in overdose education and take-home naloxone. There has been an increase in the number of prescriptions for naloxone from a baseline of 4.5 per month to an average of 46 per month during the 3 months following full implementation of the program including implementation of electronic health record alerts. Initiating and implementing an overdose education and naloxone distribution program is feasible in an academic health system. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Unified messaging solution for biosurveillance and disease surveillance.
Abellera, John P; Srinivasan, Arunkumar; Danos, C Scott; McNabb, Scott; Rhodes, Barry
2007-10-11
Biosurveillance and disease surveillance systems serve different purposes. However, the richness and quality of an existing data stream and infrastructure used in biosurveillance may prove beneficial for any state-based electronic disease surveillance system, especially if an electronic laboratory data feed does not exist between a hospital and state-based system. The use of an Enterprise Application Integration(EAI) engine, such as the BioSense Integrator,will be necessary to map heterogeneous messages into standard representations, then validate and route them [1] to a disparate system. This poster illustrates the use of an existing BioSense Integrator in order to create a unified message to support the exchange of electronic lab messages necessary for reportable disease notification. An evaluation of the infrastructure for data messaging will be examined and presented, along with a cost and benefit analysis between hospital and state-based system.
Dibble, Elizabeth H; Swenson, David W; Cobb, Cynthia; Paul, Timothy J; Karn, Andrew E; Portelli, David C; Movson, Jonathan S
2017-04-01
The goal of this project was to create a system that was easy for radiologists to use and that could reliably identify, communicate, and track communication of important but non-urgent radiology findings to providers and patients. Prior to 2012, our workflow for communicating important non-urgent diagnostic imaging results was cumbersome, rarely used by our radiologists, and resulted in delays in report turnaround time. In 2012, we developed a new system to communicate important non-urgent findings (the RADiology CATegorization 3 (RADCAT-3) system) that was easy for radiologists to use and documented communication of results in the electronic medical record. To evaluate the performance of the new system, we reviewed our radiology reports before (June 2011-June 2012) and after (June 2012-June 2014) the implementation of the new system to compare utilization by the radiologists and success in communicating these findings. During the 12 months prior to implementation, 250 radiology reports (0.06 % of all reports) entered our workflow for communicating important non-urgent findings. One-hundred percent were successfully communicated. During the 24 months after implementation, 13,158 radiology reports (1.4 % of all reports) entered our new RADCAT-3 workflow (3995 (0.8 % of all reports) during year 1 and 9163 (1.9 % of all reports) during year 2). 99.7 % of those reports were successfully communicated. We created a reliable system to ensure communication of important but non-urgent findings with providers and/or patients and to document that communication in the electronic medical record. The rapid adoption of the new system by radiologists suggests that they found it easy to use and had confidence in its integrity. This system has the potential to improve patient care by improving the likelihood of appropriate follow-up for important non-urgent findings that could become life threatening.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 232.7002 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7002 Policy. (a)(1) Contractors shall submit payment requests...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 232.7002 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7002 Policy. (a)(1) Contractors shall submit payment requests...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 232.7002 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7002 Policy. (a) Contractors shall submit payment requests and...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 232.7002 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7002 Policy. (a) Contractors shall submit payment requests and...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 232.7002 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7002 Policy. (a)(1) Contractors shall submit payment requests...
A Business Case for Electronic Commerce
1990-09-01
Electronic Commerce . This report presents the results of that examination. Based upon an examination of 16 key documents, we estimate that DoD could realize direct and indirect cost savings of almost $1.2 billion over a 10-year period by replacing these manually processed documents with their electronic equivalents. To achieve those savings, DoD would need to make investments totaling approximately $80 million in new systems and procedures. (Author)
Smith, Besa; Chu, Laura K; Smith, Tyler C; Amoroso, Paul J; Boyko, Edward J; Hooper, Tomoko I; Gackstetter, Gary D; Ryan, Margaret AK
2008-01-01
Background Self-reported medical history data are frequently used in epidemiological studies. Self-reported diagnoses may differ from medical record diagnoses due to poor patient-clinician communication, self-diagnosis in the absence of a satisfactory explanation for symptoms, or the "health literacy" of the patient. Methods The US Department of Defense military health system offers a unique opportunity to evaluate electronic medical records with near complete ascertainment while on active duty. This study compared 38 self-reported medical conditions to electronic medical record data in a large population-based US military cohort. The objective of this study was to better understand challenges and strengths in self-reporting of medical conditions. Results Using positive and negative agreement statistics for less-prevalent conditions, near-perfect negative agreement and moderate positive agreement were found for the 38 diagnoses. Conclusion This report highlights the challenges of using self-reported medical data and electronic medical records data, but illustrates that agreement between the two data sources increases with increased surveillance period of medical records. Self-reported medical data may be sufficient for ruling out history of a particular condition whereas prevalence studies may be best served by using an objective measure of medical conditions found in electronic healthcare records. Defining medical conditions from multiple sources in large, long-term prospective cohorts will reinforce the value of the study, particularly during the initial years when prevalence for many conditions may still be low. PMID:18644098
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagen, K.G.
1974-08-01
The report describes the development status of a heart assist system driven by a nuclear fueled, electronically controlled vapor cycle engine termed the tidal regenerator engine (TRE). The TRE pressurization (typically from 5-160 psia) is controlled by a torque motor coupled to a displacer. The electrical power for the sensor, electronic logic and actuator is provided by a thermoelectric module interposed between the engine superheater and boiler. The TRE is directly coupled to an assist blood pump which also acts as a blood-cooled heat exchanger, pressure-volume transformer and sensor for the electronic logic. Engine efficiencies in excess of 10 percentmore » have been demonstrated. A binary version of the engine with twice the potential efficiency is being investigated. Efficiency values as high as 13 percent have been achieved to date. (GRA)« less
Chemical modulation of electronic structure at the excited state
NASA Astrophysics Data System (ADS)
Li, F.; Song, C.; Gu, Y. D.; Saleem, M. S.; Pan, F.
2017-12-01
Spin-polarized electronic structures are the cornerstone of spintronics, and have thus attracted a significant amount of interest; in particular, researchers are looking into how to modulate the electronic structure to enable multifunctional spintronics applications, especially in half-metallic systems. However, the control of the spin polarization has only been predicted in limited two-dimensional systems with spin-polarized Dirac structures and is difficult to achieve experimentally. Here, we report the modulation of the electronic structure in the light-induced excited state in a typical half-metal, L a1 /2S r1 /2Mn O3 -δ . According to the spin-transport measurements, there appears a light-induced increase in magnetoresistance due to the enhanced spin scattering, which is closely associated with the excited spin polarization. Strikingly, the light-induced variation can be enhanced via alcohol processing and reduced by oxygen annealing. X-ray photoelectron spectroscopy measurements show that in the chemical process, a redox reaction occurs with a change in the valence of Mn. Furthermore, first-principles calculations reveal that the change in the valence of Mn alters the electronic structure and consequently modulates the spin polarization in the excited state. Our findings thus report a chemically tunable electronic structure, demonstrating interesting physics and the potential for multifunctional applications and ultrafast spintronics.
Jiang, Tao; Yu, Ping
2015-01-01
This study aims to identify the benefits of using electronic health records (EHR) for client safety in residential aged care (RAC) homes. The aged care accreditation reports published between 27 April 2011 and 3 December 2013 were downloaded and analysed. It could be seen from these reports that only 1,031(37.45%) RAC homes in Australia had adopted an EHR system by 2013. 13 RAC homes failed one or more accreditation standards. Only one of these was using an EHR system and this one met the accreditation standards on information systems. Our study provides empirical evidence to suggest that adopting and using EHR can be one of the effective organisational mechanisms to meeting accreditation standards in RAC homes.
NASA Astrophysics Data System (ADS)
Joo, Taiha; Albrecht, A. C.
1993-06-01
Time-resolved degenerate four-wave mixing (TRDFWM) for an electronically resonant system in a phase-matching configuration that measures population decay is reported. Because the spectral width of input light exceeds the vibrational Bohr frequency of a strong Raman active mode, the vibrational coherence produces strong oscillations in the TRDFWM signal together with the usual population decay from the excited electronic state. The data are analyzed in terms of a four-level system: ground and excited electronic states each split by a vibrational quantum of a Raman active mode. Absolute frequencies and their dephasing times of the vibrational modes at ≈590 cm -1 are obtained for the excited as well as the ground electronic state. The vibrational dephasing rate in the excited electronic state is about an order of magnitude faster than that in the ground state, the origin of which is speculated upon.
The evaluation of a web-based incident reporting system.
Kuo, Ya-Hui; Lee, Ting-Ting; Mills, Mary Etta; Lin, Kuan-Chia
2012-07-01
A Web-based reporting system is essential to report incident events anonymously and confidentially. The purpose of this study was to evaluate a Web-based reporting system in Taiwan. User satisfaction and impact of system use were evaluated through a survey answered by 249 nurses. Incident events reported in paper and electronic systems were collected for comparison purposes. Study variables included system user satisfaction, willingness to report, number of reports, severity of the events, and efficiency of the reporting process. Results revealed that senior nurses were less willing to report events, nurses on internal medicine units had higher satisfaction than others, and lowest satisfaction was related to the time it took to file a report. In addition, the Web-based reporting system was used more often than the paper system. The percentages of events reported were significantly higher in the Web-based system in laboratory, environment/device, and incidents occurring in other units, whereas the proportions of reports involving bedsores and dislocation of endotracheal tubes were decreased. Finally, moderate injury event reporting decreased, whereas minor or minimal injury event reporting increased. The study recommends that the data entry process be simplified and the network system be improved to increase user satisfaction and reporting rates.
Lamar, William L.; Goerlitz, Donald F.; Law, LeRoy M.
1965-01-01
Pesticides, in minute quantities, may affect the regimen of streams, and because they may concentrate in sediments, aquatic organisms, and edible aquatic foods, their detection and their measurement in the parts-per-trillion range are considered essential. In 1964 the U.S. Geological Survey at Menlo Park, Calif., began research on methods for monitoring pesticides in water. Two systems were selected--electron-capture gas chromatography and microcoulometric-titration gas chromatography. Studies on these systems are now in progress. This report provides current information on the development and application of an electron-capture gas chromatographic procedure. This method is a convenient and extremely sensitive procedure for the detection and measurement of organic pesticides having high electron affinities, notably the chlorinated organic pesticides. The electron-affinity detector is extremely sensitive to these substances but it is not as sensitive to many other compounds. By this method, the chlorinated organic pesticide may be determined on a sample of convenient size in concentrations as low as the parts-per-trillion range. To insure greater accuracy in the identifications, the pesticides reported were separated and identified by their retention times on two different types of gas chromatographic columns.
Garcia, Macarena C; Garrett, Nedra Y; Singletary, Vivian; Brown, Sheereen; Hennessy-Burt, Tamara; Haney, Gillian; Link, Kimberly; Tripp, Jennifer; Mac Kenzie, William R; Yoon, Paula
2017-12-07
State and local public health agencies collect and use surveillance data to identify outbreaks, track cases, investigate causes, and implement measures to protect the public-s health through various surveillance systems and data exchange practices. The purpose of this assessment was to better understand current practices at state and local public health agencies for collecting, managing, processing, reporting, and exchanging notifiable disease surveillance information. Over an 18-month period (January 2014-June 2015), we evaluated the process of data exchange between surveillance systems, reporting burdens, and challenges within 3 states (California, Idaho, and Massachusetts) that were using 3 different reporting systems. All 3 states use a combination of paper-based and electronic information systems for managing and exchanging data on reportable conditions within the state. The flow of data from local jurisdictions to the state health departments varies considerably. When state and local information systems are not interoperable, manual duplicative data entry and other work-arounds are often required. The results of the assessment show the complexity of disease reporting at the state and local levels and the multiple systems, processes, and resources engaged in preparing, processing, and transmitting data that limit interoperability and decrease efficiency. Through this structured assessment, the Centers for Disease Control and Prevention (CDC) has a better understanding of the complexities for surveillance of using commercial off-the-shelf data systems (California and Massachusetts), and CDC-developed National Electronic Disease Surveillance System Base System. More efficient data exchange and use of data will help facilitate interoperability between National Notifiable Diseases Surveillance Systems.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-25
... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Parts 219 and 252 [DFARS Case... System AGENCY: Defense Acquisition Regulations System, Department of Defense (DoD). ACTION: Interim rule... Supplement (DFARS) to conform to the Federal Acquisition Regulation (FAR) by providing Department of Defense...
... on Vital and Health Statistics Annual Reports Health Survey Research Methods Conference Reports from the National Medical Care Utilization and Expenditure Survey Clearinghouse on Health Indexes Statistical Notes for Health ...
Advance traffic control warning systems for maintenance operations : final report.
DOT National Transportation Integrated Search
1976-07-01
The report discusses the effect of certain variables defined by sign size, height of installation and legend on the driver responses as measured by speed, conflict and queuing parameters. Effects of electronically actuated, directional flashing signs...
Safety and fitness electronic records system (SAFER) : master test plan
DOT National Transportation Integrated Search
2000-01-01
This report contains highway design informaiton that will help accomodate the needs and capability of older road users. Specifically, it contains the recommendaitons section of a larger report titled: Older Driver Highway Design Handbook (FHWA-RD-97-...
Commercial Vehicle Architecture Systems Study, Volume II: Task Reports
DOT National Transportation Integrated Search
1993-10-01
WEIGH-IN-MOTION OR WIM, DRIVER PERFORMANCE MONITORING, ELECTRONIC DATA INTERCHANGE OR EDI, COMMERCIAL VEHICLE OPERATIONS OR CVO : THIS REPORT DETAILS PROGRESS TO DATE ON A SET OF TASKS BEING PERFORMED BY SANDIA NATIONAL LABORATORIES (SNL) FOR THE ...
Near-Infrared Plasmon-Assisted Water Oxidation.
Nishijima, Yoshiaki; Ueno, Kosei; Kotake, Yuki; Murakoshi, Kei; Inoue, Haruo; Misawa, Hiroaki
2012-05-17
We report the stoichiometric evolution of oxygen via water oxidation by irradiating a plasmon-enhanced photocurrent generation system with near-infrared light (λ: 1000 nm), in which gold nanostructures were arrayed on the surface of TiO2 electrode. It is considered that multiple electron holes generated by plasmon-induced charge excitation led to the effective recovery of water oxidation after the electron transfer from gold to TiO2. The proposed system containing a gold nanostructured TiO2 electrode may be a promising artificial photosynthetic system using near-infrared light.
Large-Scale Production of Carbon Nanotubes Using the Jefferson Lab Free Electron Laser
NASA Technical Reports Server (NTRS)
Holloway, Brian C.
2003-01-01
We report on our interdisciplinary program to use the Free Electron Laser (FEL) at the Thomas Jefferson National Accelerator Facility (J-Lab) for high-volume pulsed laser vaporization synthesis of carbon nanotubes. Based in part on the funding of from this project, a novel nanotube production system was designed, tested, and patented. Using this new system nanotube production rates over 100 times faster than conventional laser systems were achieved. Analysis of the material produced shows that it is of as high a quality as the standard laser-based materials.
Numerical studies of the topological Chern numbers in two dimensional electron system
NASA Astrophysics Data System (ADS)
Sheng, Donna
2004-03-01
I will report on the numerical results of the exact calculation of the topological Chern numbers in fractional and bilayer quantum Hall systems[1]. I will show that following the evolution of the Chern numbers as a function of the disorder strength and/or layer separations, various quantum phase transitions as well as the characteristic transport properties of the phases, can be determined. The hidden topological ordering in other two dimensional electron systems will also be discussed. 1. D. N. Sheng et. al., Phys. Rev. Lett. 90, 256802 (2003).
DOT National Transportation Integrated Search
2004-12-06
These are the appendices for the report describing the findings of the US DOT-sponsored evaluation of the Orlando (Florida) ORANGES multi-modal Field Operational Test (FOT); the report includes: a background description of the ORANGES FOT; the Evalua...
DOT National Transportation Integrated Search
2004-12-06
This report describes the findings of the US DOT-sponsored evaluation of the Orlando (Florida) ORANGES multi-modal Field Operational Test (FOT); the report includes: a background description of the ORANGES FOT; the Evaluation Strategy and Plan, which...
Biswas, Abul Kalam; Barik, Sunirmal; Das, Amitava; Ganguly, Bishwajit
2016-06-01
We have reported a number of new metal-free organic dyes (2-6) that have cyclic asymmetric benzotripyrrole derivatives as donor groups with peripheral nitrogen atoms in the ring, fluorine and thiophene groups as π-spacers, and a cyanoacrylic acid acceptor group. Density functional theory (DFT) and time-dependent DFT (TD-DFT) calculations were employed to examine the influence of the position of the donor nitrogen atom and π-conjugation on solar cell performance. The calculated electron-injection driving force (ΔG inject), electron-regeneration driving force (ΔG regen), light-harvesting efficiency (LHE), dipole moment (μ normal), and number of electrons transferred (∆q) indicate that dyes 3, 4, and 6 have significantly higher efficiencies than reference dye 1, which exhibits high efficiency. We also extended our comparison to some other reported dyes, 7-9, which have a donor nitrogen atom in the middle of the ring system. The computed results suggest that dye 6 possesses a higher incident photon to current conversion efficiency (IPCE) than reported dyes 7-9. Thus, the use of donor groups with peripheral nitrogen atoms appears to lead to more efficient dyes than those in which the nitrogen atom is present in the middle of the donor ring system. Graphical Abstract The locations of the nitrogen atoms in the donor groups in the designed dye molecules have an important influence on DSSC efficiency.
The SPARC_LAB femtosecond synchronization for electron and photon pulsed beams
NASA Astrophysics Data System (ADS)
Bellaveglia, M.; Gallo, A.; Piersanti, L.; Pompili, R.; Gatti, G.; Anania, M. P.; Petrarca, M.; Villa, F.; Chiadroni, E.; Biagioni, A.; Mostacci, A.
2015-05-01
The SPARC LAB complex hosts a 150 MeV electron photo-injector equipped with an undulator for FEL production (SPARC) together with a high power TW laser (FLAME). Recently the synchronization system reached the performance of < 100 fsRMS relative jitter between lasers, electron beam and RF accelerating fields. This matches the requirements for next future experiments: (i) the production of X-rays by means of Thomson scattering (first collisions achieved in 2014) and (ii) the particle driven PWFA experiment by means of multiple electron bunches. We report about the measurements taken during the machine operation using BAMs (Bunch Arrival Monitors) and EOS (Electro-Optical Sampling) system. A new R and D activity concerning the LWFA using the external injection of electron bunches in a plasma generated by the FLAME laser pulse is under design. The upgrade of the synchronization system is under way to guarantee the < 30 fs RMS jitter required specification. It foresees the transition from electrical to optical architecture that mainly affects the reference signal distribution and the time of arrival detection performances. The new system architecture is presented together with the related experimental data.
Resist characteristics with direct-write electron beam and SCALPEL exposure system
NASA Astrophysics Data System (ADS)
Sato, Mitsuru; Omori, Katsumi; Ishikawa, Kiyoshi; Nakayama, Toshimasa; Novembre, Anthony E.; Ocola, Leonidas E.
1999-06-01
High acceleration voltage electron beam exposure is one of the possible candidates for post-optical lithography. The use of electrons, instead of photons, avoids optical related problems such as the standing wave issues. However, resists must conform to certain needs for the SCALPEL system, such as exposure in a vacuum chamber with 100kv electron beams. Taking into account the challenging requirements of high resolution, high sensitivity, low bake dependency and no outgassing, TOK has been able to develop resists to meet most of the SCALPEL system needs. However, due to the nature of chemical amplification and the PEB dependency, as is the case with DUV resist which varies for different features, we must recommend different resist for multiple features such as dense lines, isolated lines and contact holes. TOK has designed an electron beam negative resist, EN-009, which demonstrate 100nm pattern resolution. The dose to print on the SCALPEL system is 5.0(mu) C/cm2. The electron beam positive resist, EP-004M, has been designed for line and space patterns. The dose to print on the SCALPEL system is 8.25(mu) C/cm2. The processing conditions are standard, using 0.26N developer. These are the lowest exposure energies reported to date for similar resolution on this exposure tools.
Imaging Electron Spectrometer (IES) Electron Preprocessor (EPP) Design
NASA Technical Reports Server (NTRS)
Fennell, J. F.; Osborn, J. V.; Christensen, John L. (Technical Monitor)
2001-01-01
The Aerospace Corporation developed the Electron PreProcessor (EPP) to support the Imaging Electron Spectrometer (IES) that is part of the RAPID experiment on the ESA/NASA CLUSTER mission. The purpose of the EPP is to collect raw data from the IES and perform processing and data compression on it before transferring it to the RAPID microprocessor system for formatting and transmission to the CLUSTER satellite data system. The report provides a short history of the RAPID and CLUSTER programs and describes the EPP design. Four EPP units were fabricated, tested, and delivered for the original CLUSTER program. These were destroyed during a launch failure. Four more EPP units were delivered for the CLUSTER II program. These were successfully launched and are operating nominally on orbit.
Automated Transformation of CDISC ODM to OpenClinica.
Gessner, Sophia; Storck, Michael; Hegselmann, Stefan; Dugas, Martin; Soto-Rey, Iñaki
2017-01-01
Due to the increasing use of electronic data capture systems for clinical research, the interest in saving resources by automatically generating and reusing case report forms in clinical studies is growing. OpenClinica, an open-source electronic data capture system enables the reuse of metadata in its own Excel import template, hampering the reuse of metadata defined in other standard formats. One of these standard formats is the Operational Data Model for metadata, administrative and clinical data in clinical studies. This work suggests a mapping from Operational Data Model to OpenClinica and describes the implementation of a converter to automatically generate OpenClinica conform case report forms based upon metadata in the Operational Data Model.
Heinrich, J; Putzar, H; Seidenschnur, G
1977-01-01
Report about an electronic data processing system for obstetrics and perinatology. The developed data document design and data flowchart are shown. The continuously accumulated data allowed everytime a detailed interpretation record. For all clinical treated patients the computer printed out a final obstetrical report (physician report). By means of this simple system there is an improvement of the information and the typewriting work of medical staff has been reduced. Cost and work-expenditure for this system are limited in relation to our earlier hand made procedure.
48 CFR 204.604 - Responsibilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 204.604 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Contract Reporting 204.604 Responsibilities. (1) The... in the associated Government contract file instead of including a paper copy of the electronically...
48 CFR 204.604 - Responsibilities.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 204.604 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Contract Reporting 204.604 Responsibilities. (1) The... in the associated Government contract file instead of including a paper copy of the electronically...
48 CFR 204.604 - Responsibilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 204.604 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Contract Reporting 204.604 Responsibilities. (1) The... in the associated Government contract file instead of including a paper copy of the electronically...
48 CFR 204.604 - Responsibilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 204.604 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Contract Reporting 204.604 Responsibilities. (1) The... in the associated Government contract file instead of including a paper copy of the electronically...
48 CFR 204.604 - Responsibilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 204.604 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Contract Reporting 204.604 Responsibilities. (1) The... in the associated Government contract file instead of including a paper copy of the electronically...
48 CFR 232.7004 - Contract clause.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clause. (a) Except as provided in 232...
48 CFR 232.7004 - Contract clauses.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clauses. (a) Except as provided in 232...
48 CFR 232.7000 - Scope of subpart.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 232.7000 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7000 Scope of subpart. This subpart prescribes policies...
48 CFR 232.7000 - Scope of subpart.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 232.7000 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7000 Scope of subpart. This subpart prescribes policies...
48 CFR 232.7000 - Scope of subpart.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 232.7000 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7000 Scope of subpart. This subpart prescribes policies...
48 CFR 232.7004 - Contract clause.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clause. (a) Except as provided in 232...
48 CFR 232.7000 - Scope of subpart.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 232.7000 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7000 Scope of subpart. This subpart prescribes policies...
48 CFR 232.7000 - Scope of subpart.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 232.7000 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7000 Scope of subpart. This subpart prescribes policies...
Evaluation of Embedded System Component Utilized in Delivery Integrated Design Project Course
NASA Astrophysics Data System (ADS)
Junid, Syed Abdul Mutalib Al; Hussaini, Yusnira; Nazmie Osman, Fairul; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul
2018-03-01
This paper reports the evaluation of the embedded system component utilized in delivering the integrated electronic engineering design project course. The evaluation is conducted based on the report project submitted as to fulfil the assessment criteria for the integrated electronic engineering design project course named; engineering system design. Six projects were assessed in this evaluation. The evaluation covers the type of controller, programming language and the number of embedded component utilization as well. From the evaluation, the C-programming based language is the best solution preferred by the students which provide them flexibility in the programming. Moreover, the Analog to Digital converter is intensively used in the projects which include sensors in their proposed design. As a conclusion, in delivering the integrated design project course, the knowledge over the embedded system solution is very important since the high density of the knowledge acquired in accomplishing the project assigned.
MIT Lincoln Laboratory 2010 Facts
2010-03-01
currently valid OMB control number. 1. REPORT DATE 2010 2. REPORT TYPE 3. DATES COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE MIT Lincoln...space control ; air and missile defense; communications and information technology; intelligence, surveillance, and reconnaissance systems...advanced electronics; tactical systems; homeland protection and biological/chemical defense; and air traffic control . Two of the Laboratory’s principal
EMC (Electromagnetic Compatibility) Standards Handbook. Revision 4,
1982-11-01
report was prepared by the lIT Research Institute as part of AF Project 649E under Contract F-19628-80-C-0042 with the Electronic Systems Division of...the Air Pbrce Systems Command in support of the DoD Electromagnetic Compatibility Analysis Center, Annapolis, Maryland. This report has been reviewed...3-1 "JVDE Organizations .. .0 . . . . . . . . . . . . . . . . . . . . . 3 1 VDE Testing Station
Wysham, Nicholas G; Abernethy, Amy P; Cox, Christopher E
2014-10-01
Prediction models in critical illness are generally limited to short-term mortality and uncommonly include patient-centered outcomes. Current outcome prediction tools are also insensitive to individual context or evolution in healthcare practice, potentially limiting their value over time. Improved prognostication of patient-centered outcomes in critical illness could enhance decision-making quality in the ICU. Patient-reported outcomes have emerged as precise methodological measures of patient-centered variables and have been successfully employed using diverse platforms and technologies, enhancing the value of research in critical illness survivorship and in direct patient care. The learning health system is an emerging ideal characterized by integration of multiple data sources into a smart and interconnected health information technology infrastructure with the goal of rapidly optimizing patient care. We propose a vision of a smart, interconnected learning health system with integrated electronic patient-reported outcomes to optimize patient-centered care, including critical care outcome prediction. A learning health system infrastructure integrating electronic patient-reported outcomes may aid in the management of critical illness-associated conditions and yield tools to improve prognostication of patient-centered outcomes in critical illness.
Automated pinhole-aperture diagnostic for the current profiling of TWT electron beams
NASA Astrophysics Data System (ADS)
Wei, Yu-Xiang; Huang, Ming-Guang; Liu, Shu-Qing; Liu, Jin-Yue; Hao, Bao-Liang; Du, Chao-Hai; Liu, Pu-Kun
2013-02-01
The measurement system reported here is intended for use in determining the current density distribution of electron beams from Pierce guns for use in TWTs. The system was designed to automatically scan the cross section of the electron beam and collect the high-resolution data with a Faraday cup probe mounted on a multistage manipulator using the LabVIEW program. A 0.06 mm thick molybdenum plate with a pinhole and a Faraday cup mounted as a probe assembly was employed to sample the electron beam current with 0.5 µm space resolution. The thermal analysis of the probe with pulse beam heating was discussed. A 0.45 µP electron gun with the expected minimum beam radius 0.42 mm was measured and the three-dimensional current density distribution, beam envelope and phase space were presented.
NASA Technical Reports Server (NTRS)
Johnson, Paul W.
2008-01-01
ePORT (electronic Project Online Risk Tool) provides a systematic approach to using an electronic database program to manage a program/project risk management processes. This presentation will briefly cover the standard risk management procedures, then thoroughly cover NASA's Risk Management tool called ePORT. This electronic Project Online Risk Tool (ePORT) is a web-based risk management program that provides a common framework to capture and manage risks, independent of a programs/projects size and budget. It is used to thoroughly cover the risk management paradigm providing standardized evaluation criterion for common management reporting, ePORT improves Product Line, Center and Corporate Management insight, simplifies program/project manager reporting, and maintains an archive of data for historical reference.
Anti-Idling Battery for Truck Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keith Kelly
2011-09-30
In accordance to the Assistance Agreement DE-EE0001036, the objective of this project was to develop an advanced high voltage lithium-ion battery for use in an all-electric HVAC system for Class-7-8 heavy duty trucks. This system will help heavy duty truck drivers meet the tough new anti-idling laws being implemented by over 23 states. Quallion will be partnering with a major OEM supplier of HVAC systems to develop this system. The major OEM supplier will provide Quallion the necessary interface requirements and HVAC hardware to ensure successful testing of the all-electric system. At the end of the program, Quallion will delivermore » test data on three (3) batteries as well as test data for the prototype HVAC system. The objectives of the program are: (1) Battery Development - Objective 1 - Define battery and electronics specifications in preparation for building the prototype module. (Completed - summary included in report) and Objective 2 - Establish a functional prototype battery and characterize three batteries in-house. (Completed - photos and data included in report); (2) HVAC Development - Objective 1 - Collaborate with manufacturers to define HVAC components, layout, and electronics in preparation for establishing the prototype system. (Completed - photos and data included in report) and Objective 2 - Acquire components for three functional prototypes for use by Quallion. (Completed - photos and data included in report).« less
User-interactive electronic skin for instantaneous pressure visualization
NASA Astrophysics Data System (ADS)
Wang, Chuan; Hwang, David; Yu, Zhibin; Takei, Kuniharu; Park, Junwoo; Chen, Teresa; Ma, Biwu; Javey, Ali
2013-10-01
Electronic skin (e-skin) presents a network of mechanically flexible sensors that can conformally wrap irregular surfaces and spatially map and quantify various stimuli. Previous works on e-skin have focused on the optimization of pressure sensors interfaced with an electronic readout, whereas user interfaces based on a human-readable output were not explored. Here, we report the first user-interactive e-skin that not only spatially maps the applied pressure but also provides an instantaneous visual response through a built-in active-matrix organic light-emitting diode display with red, green and blue pixels. In this system, organic light-emitting diodes (OLEDs) are turned on locally where the surface is touched, and the intensity of the emitted light quantifies the magnitude of the applied pressure. This work represents a system-on-plastic demonstration where three distinct electronic components—thin-film transistor, pressure sensor and OLED arrays—are monolithically integrated over large areas on a single plastic substrate. The reported e-skin may find a wide range of applications in interactive input/control devices, smart wallpapers, robotics and medical/health monitoring devices.
User-interactive electronic skin for instantaneous pressure visualization.
Wang, Chuan; Hwang, David; Yu, Zhibin; Takei, Kuniharu; Park, Junwoo; Chen, Teresa; Ma, Biwu; Javey, Ali
2013-10-01
Electronic skin (e-skin) presents a network of mechanically flexible sensors that can conformally wrap irregular surfaces and spatially map and quantify various stimuli. Previous works on e-skin have focused on the optimization of pressure sensors interfaced with an electronic readout, whereas user interfaces based on a human-readable output were not explored. Here, we report the first user-interactive e-skin that not only spatially maps the applied pressure but also provides an instantaneous visual response through a built-in active-matrix organic light-emitting diode display with red, green and blue pixels. In this system, organic light-emitting diodes (OLEDs) are turned on locally where the surface is touched, and the intensity of the emitted light quantifies the magnitude of the applied pressure. This work represents a system-on-plastic demonstration where three distinct electronic components--thin-film transistor, pressure sensor and OLED arrays--are monolithically integrated over large areas on a single plastic substrate. The reported e-skin may find a wide range of applications in interactive input/control devices, smart wallpapers, robotics and medical/health monitoring devices.
Fukuda, Kenjiro; Someya, Takao
2017-07-01
Printed electronics enable the fabrication of large-scale, low-cost electronic devices and systems, and thus offer significant possibilities in terms of developing new electronics/optics applications in various fields. Almost all electronic applications require information processing using logic circuits. Hence, realizing the high-speed operation of logic circuits is also important for printed devices. This report summarizes recent progress in the development of printed thin-film transistors (TFTs) and integrated circuits in terms of materials, printing technologies, and applications. The first part of this report gives an overview of the development of functional inks such as semiconductors, electrodes, and dielectrics. The second part discusses high-resolution printing technologies and strategies to enable high-resolution patterning. The main focus of this report is on obtaining printed electrodes with high-resolution patterning and the electrical performance of printed TFTs using such printed electrodes. In the final part, some applications of printed electronics are introduced to exemplify their potential. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Local 2D-2D tunneling in high mobility electron systems
NASA Astrophysics Data System (ADS)
Pelliccione, Matthew; Sciambi, Adam; Bartel, John; Goldhaber-Gordon, David; Pfeiffer, Loren; West, Ken; Lilly, Michael; Bank, Seth; Gossard, Arthur
2012-02-01
Many scanning probe techniques have been utilized in recent years to measure local properties of high mobility two-dimensional (2D) electron systems in GaAs. However, most techniques lack the ability to tunnel into the buried 2D system and measure local spectroscopic information. We report scanning gate measurements on a bilayer GaAs/AlGaAs heterostructure that allows for a local modulation of tunneling between two 2D electron layers. We call this technique Virtual Scanning Tunneling Microscopy (VSTM) [1,2] as the influence of the scanning gate is analogous to an STM tip, except at a GaAs/AlGaAs interface instead of a surface. We will discuss the spectroscopic capabilities of the technique, and show preliminary results of measurements on a high mobility 2D electron system.[1] A. Sciambi, M. Pelliccione et al., Appl. Phys. Lett. 97, 132103 (2010).[2] A. Sciambi, M. Pelliccione et al., Phys. Rev. B 84, 085301 (2011).
Brazovskii, Serguei; Brun, Christophe; Wang, Zhao-Zhong; Monceau, Pierre
2012-03-02
We report on scanning-tunneling microscopy experiments in a charge-density wave (CDW) system allowing visually capturing and studying in detail the individual solitons corresponding to the self-trapping of just one electron. This "Amplitude Soliton" is marked by vanishing of the CDW amplitude and by the π shift of its phase. It might be the realization of the spinon--the long-sought particle (along with the holon) in the study of science of strongly correlated electronic systems. As a distinct feature we also observe one-dimensional Friedel oscillations superimposed on the CDW which develop independently of solitons.
NASA Astrophysics Data System (ADS)
Koestner, Stefan
2009-09-01
With the increasing size and degree of complexity of today's experiments in high energy physics the required amount of work and complexity to integrate a complete subdetector into an experiment control system is often underestimated. We report here on the layered software structure and protocols used by the LHCb experiment to control its detectors and readout boards. The experiment control system of LHCb is based on the commercial SCADA system PVSS II. Readout boards which are outside the radiation area are accessed via embedded credit card sized PCs which are connected to a large local area network. The SPECS protocol is used for control of the front end electronics. Finite state machines are introduced to facilitate the control of a large number of electronic devices and to model the whole experiment at the level of an expert system.
Electronic integrated disease surveillance system and pathogen asset control system.
Wahl, Tom G; Burdakov, Aleksey V; Oukharov, Andrey O; Zhilokov, Azamat K
2012-06-20
Electronic Integrated Disease Surveillance System (EIDSS) has been used to strengthen and support monitoring and prevention of dangerous diseases within One Health concept by integrating veterinary and human surveillance, passive and active approaches, case-based records including disease-specific clinical data based on standardised case definitions and aggregated data, laboratory data including sample tracking linked to each case and event with test results and epidemiological investigations. Information was collected and shared in secure way by different means: through the distributed nodes which are continuously synchronised amongst each other, through the web service, through the handheld devices. Electronic Integrated Disease Surveillance System provided near real time information flow that has been then disseminated to the appropriate organisations in a timely manner. It has been used for comprehensive analysis and visualisation capabilities including real time mapping of case events as these unfold enhancing decision making. Electronic Integrated Disease Surveillance System facilitated countries to comply with the IHR 2005 requirements through a data transfer module reporting diseases electronically to the World Health Organisation (WHO) data center as well as establish authorised data exchange with other electronic system using Open Architecture approach. Pathogen Asset Control System (PACS) has been used for accounting, management and control of biological agent stocks. Information on samples and strains of any kind throughout their entire lifecycle has been tracked in a comprehensive and flexible solution PACS.Both systems have been used in a combination and individually. Electronic Integrated Disease Surveillance System and PACS are currently deployed in the Republics of Kazakhstan, Georgia and Azerbaijan as a part of the Cooperative Biological Engagement Program (CBEP) sponsored by the US Defense Threat Reduction Agency (DTRA).
Innovative technologies in course Electrical engineering and electronics
NASA Astrophysics Data System (ADS)
Kuznetsov, E. V.; Kiselev, V. I.; Kulikova, E. A.
2017-11-01
Department of Electrical Engineering and Nondestructive Testing, NRU “MPEI”, has been working on development Electronic Learning Resources (ELRs) in course Electrical Engineering and Electronics for several years. This work have been focused on education intensification and effectiveness while training bachelors in nonelectrical specializations including students from Thermal and Atomic Power Engineering Institute. The developed ELRs are united in a tutorial module consisting of three parts (Electrical Circuits, Electrical Machines, Basics of Electronics): electronic textbook and workbook (ETW); virtual laboratory sessions (VLS); training sessions (ETS); personal tasks (PT); testing system that contains electronic tests in all course subjects and built-in verification of a student’s work results in ETW, VLS, ETS, PT. The report presents samples of different ELRs in html format and MathCAD, MatLAB Simulink applications, copyrighted programs in Java2, Delphi, VB6, C++. The report also contains the experience description, advantages and disadvantages of the new technologies. It is mentioned that ELRs provide new opportunities in course studying.
SU-E-T-524: Web-Based Radiation Oncology Incident Reporting and Learning System (ROIRLS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapoor, R; Palta, J; Hagan, M
Purpose: Describe a Web-based Radiation Oncology Incident Reporting and Learning system that has the potential to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: The VA National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and near miss data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. Software used for this program is deployed on the VAs intranet as a Website. All data entry forms (adverse event or near missmore » reports, work product reports) utilize standard causal, RT process step taxonomies and data dictionaries defined in AAPM and ASTRO reports on error reporting (AAPM Work Group Report on Prevention of Errors and ASTROs safety is no accident report). All reported incidents are investigated by the radiation oncology domain experts. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The operational workflow is similar to that of the Aviation Safety Reporting System. This system is also synergistic with ROSIS and SAFRON. Results: The ROIRLS facilitates the collection of data that help in tracking adverse events and near misses and develop new interventions to prevent such incidents. The ROIRLS electronic infrastructure is fully integrated with each registered facility profile data thus minimizing key strokes and multiple entries by the event reporters. Conclusions: OIRLS is expected to improve the quality and safety of a broad spectrum of radiation therapy patients treated in the VA and fulfills our goal of Effecting Quality While Treating Safely The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations Inc. and is deployed on the VA intranet as a Website. The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations Inc. and is deployed on the VA intranet as a Website.« less
Patient Compliance With Electronic Patient Reported Outcomes Following Shoulder Arthroscopy.
Makhni, Eric C; Higgins, John D; Hamamoto, Jason T; Cole, Brian J; Romeo, Anthony A; Verma, Nikhil N
2017-11-01
To determine the patient compliance in completing electronically administered patient-reported outcome (PRO) scores following shoulder arthroscopy, and to determine if dedicated research assistants improve patient compliance. Patients undergoing arthroscopic shoulder surgery from January 1, 2014, to December 31, 2014, were prospectively enrolled into an electronic data collection system with retrospective review of compliance data. A total of 143 patients were included in this study; 406 patients were excluded (for any or all of the following reasons, such as incomplete follow-up, inaccessibility to the order sets, and inability to complete the order sets). All patients were assigned an order set of PROs through an electronic reporting system, with order sets to be completed prior to surgery, as well as 6 and 12 months postoperatively. Compliance rates of form completion were documented. Patients who underwent arthroscopic anterior and/or posterior stabilization were excluded. The average age of the patients was 53.1 years, ranging from 20 to 83. Compliance of form completion was highest preoperatively (76%), and then dropped subsequently at 6 months postoperatively (57%) and 12 months postoperatively (45%). Use of research assistants improved compliance by approximately 20% at each time point. No differences were found according to patient gender and age group. Of those completing forms, a majority completed forms at home or elsewhere prior to returning to the office for the clinic visit. Electronic administration of PRO may decrease the amount of time required in the office setting for PRO completion by patients. This may be mutually beneficial to providers and patients. It is unclear if an electronic system improves patient compliance in voluntary completion PRO. Compliance rates at final follow-up remain a concern if data are to be used for establishing quality or outcome metrics. Level IV, case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
DOT National Transportation Integrated Search
2009-03-20
International Electronic Machines Corporation (IEM) has developed and is now marketing a state-of-the-art Wheel Inspection System Environment (WISE). WISE provides wheel profile and dimensional measurements, i.e. rim thickness, flange height, flange ...
48 CFR 232.7004 - Contract clause.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clause. Except as provided in 232.7002(a...
48 CFR 232.7004 - Contract clause.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clause. Except as provided in 232.7002(a...
Power Electronics Thermal Management Research: Annual Progress Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moreno, Gilberto
The objective for this project is to develop thermal management strategies to enable efficient and high-temperature wide-bandgap (WBG)-based power electronic systems (e.g., emerging inverter and DC-DC converter). Reliable WBG devices are capable of operating at elevated temperatures (≥ 175 °Celsius). However, packaging WBG devices within an automotive inverter and operating them at higher junction temperatures will expose other system components (e.g., capacitors and electrical boards) to temperatures that may exceed their safe operating limits. This creates challenges for thermal management and reliability. In this project, system-level thermal analyses are conducted to determine the effect of elevated device temperatures on invertermore » components. Thermal modeling work is then conducted to evaluate various thermal management strategies that will enable the use of highly efficient WBG devices with automotive power electronic systems.« less
NASA Technical Reports Server (NTRS)
1992-01-01
The NASA Marshall Space Flight Center Annual Report is presented. A description of research and development projects is included. Topics covered include: space science; space systems; transportation systems; astronomy and astrophysics; earth sciences; solar terrestrial physics; microgravity science; diagnostic and inspection system; information, electronic, and optical systems; materials and manufacturing; propulsion; and structures and dynamics.
The High Tech Road to Making an Oral Report.
ERIC Educational Resources Information Center
Wirths, Claudine G.; Bowman-Kruhm, Mary
Using the "3 R's of Reporting" (Research, Reinforce, Rehearse) provides the process secondary students need to overcome their fear of making oral presentations. Much of this anxiety can be reduced by teaching students to use electronic supports for the research, preparation, and delivery of oral reports. Online bulletin board systems,…
Monitoring Shuttle Burns and Rocket Launches with GPS
NASA Astrophysics Data System (ADS)
Coster, A. J.; Bhatt, A.; O'Hanlon, B.; Rideout, W.
2009-12-01
We report on different GPS analysis techniques that can be used to examine the effects of rocket exhaust on the upper atmosphere. GPS observations of artificially produced electron density holes created by chemical releases from Space Shuttle Orbital Maneuvering System (OMS) engine burns will be discussed. The percentage drop in total electron content (TEC) and the temporal and spatial scales observed in the electron density hole for different Shuttle burn experiments will be compared. We will also report on observations of TEC depletions associated with Titan rocket launches on 8 April 2003 and on 19 October 2005. Finally we will discuss the use of GPS measurements of precipitable water vapor from time periods before, during, and after Shuttle burns.
Sohlberg, Karl; Bazargan, Gloria; Angelo, Joseph P; Lee, Choongkeun
2017-01-01
Herein we report a study of the switchable [3]rotaxane reported by Huang et al. (Appl Phys Lett 85(22):5391-5393, 1) that can be mounted to a surface to form a nanomechanical, linear, molecular motor. We demonstrate the application of semiempirical electronic structure theory to predict the average and instantaneous force generated by redox-induced ring shuttling. Detailed analysis of the geometric and electronic structure of the system reveals technical considerations essential to success of the approach. The force is found to be in the 100-200 pN range, consistent with published experimental estimates. Graphical Abstract A single surface-mounted switchable rotaxane.
Technology for large space systems: A bibliography with indexes (supplement 07)
NASA Technical Reports Server (NTRS)
1983-01-01
This bibliography lists 366 reports, articles and other documents introduced into the NASA scientific and technical information system between January 1, 1982 and June 30, 1982. Subject matter is grouped according to systems, interactive analysis and design, structural concepts, control systems, electronics, advanced materials, assembly concepts, propulsion, solar power satellite systems, and flight experiments.
Aagaard, Lise; Stenver, Doris Irene; Hansen, Ebba Holme
2008-10-01
To explore the organisational structure and processes of the Danish and Australian spontaneous ADR reporting systems with a view to how information is generated about new ADRs. The Danish and Australian spontaneous ADR reporting systems. Qualitative analyses of documentary material, descriptive interviews with key informants, and observations were made. We analysed the organisational structure of the Danish and Australian ADR reporting systems with respect to structures and processes, including information flow and exchange of ADR data. The analysis was made based on Scott's adapted version of Leavitt's diamond model, with the components: goals/tasks, social structure, technology and participants, within a surrounding environment. The main differences between the systems were: (1) PARTICIPANTS: Outsourcing of ADR assessments to the pharmaceutical companies complicates maintenance of scientific skills within the Danish Medicines Agency (DKMA), as it leaves the handling of spontaneous ADR reports purely administrative within the DKMA, and the knowledge creation process remains with the pharmaceutical companies, while in Australia senior scientific staff work with evaluation of the ADR report; (2) Goals/tasks: In Denmark, resources are targeted at evaluating Periodic Safety Update Reports (PSUR) submitted by the companies, while the resources in Australia are focused on single case assessment resulting in faster and more proactive medicine surveillance; (3) Social structure: Discussions between scientific staff about ADRs take place in Australia, while the Danish system primarily focuses on entering and forwarding ADR data to the relevant pharmaceutical companies; (4) Technology: The Danish system exchanges ADR data electronically with pharmaceutical companies and the other EU countries, while Australia does not have a system for electronic exchange of ADR data; and (5) ENVIRONMENT: The Danish ADR system is embedded in the routines of cooperation within European pharmacovigilance network while the Australian system is acting alone, although they communicate with other systems. The two systems differ with regard to reporting requirements, report handling, resources being spent and information exchange with the environment. In Denmark, learning about ADRs primarily takes place in the safety divisions of the pharmaceutical companies and the authorities have no control over the knowledge creation process. In Australia, more learning and control of the knowledge is present than in Denmark.
Two-dimensional Electronic Double-Quantum Coherence Spectroscopy
Kim, Jeongho; Mukamel, Shaul
2009-01-01
CONSPECTUS The theory of electronic structure of many-electron systems like molecules is extraordinarily complicated. A lot can be learned by considering how electron density is distributed, on average, in the average field of the other electrons in the system. That is, mean field theory. However, to describe quantitatively chemical bonds, reactions, and spectroscopy requires consideration of the way that electrons avoid each other by the way they move; this is called electron correlation (or in physics, the many-body problem for fermions). While great progress has been made in theory, there is a need for incisive experimental tests that can be undertaken for large molecular systems in the condensed phase. Here we report a two-dimensional (2D) optical coherent spectroscopy that correlates the double excited electronic states to constituent single excited states. The technique, termed two-dimensional double-coherence spectroscopy (2D-DQCS), makes use of multiple, time-ordered ultrashort coherent optical pulses to create double- and single-quantum coherences over time intervals between the pulses. The resulting two-dimensional electronic spectrum maps the energy correlation between the first excited state and two-photon allowed double-quantum states. The principle of the experiment is that when the energy of the double-quantum state, viewed in simple models as a double HOMO to LUMO excitation, equals twice that of a single excitation, then no signal is radiated. However, electron-electron interactions—a combination of exchange interactions and electron correlation—in real systems generates a signal that reveals precisely how the energy of the double-quantum resonance differs from twice the single-quantum resonance. The energy shift measured in this experiment reveals how the second excitation is perturbed by both the presence of the first excitation and the way that the other electrons in the system have responded to the presence of that first excitation. We compare a series of organic dye molecules and find that the energy offset for adding a second electronic excitation to the system relative to the first excitation is on the order of tens of milli-electronvolts, and it depends quite sensitively on molecular geometry. These results demonstrate the effectiveness of 2D-DQCS for elucidating quantitative information about electron-electron interactions, many-electron wavefunctions, and electron correlation in electronic excited states and excitons. PMID:19552412
Report #17-P-0029, November 7, 2016. Ineffective project oversight could cause project delays that prolong the EPA's ability to provide emergency responders with data about hazardous waste shipped between generators’ sites and waste management facilities.
DOT National Transportation Integrated Search
1999-01-01
The electronic cone penetrometer is a popular in situ investigation tool for site characterization. This research report describes the application of this proven concept of the cone penetration test (CPT) to highway design and construction control by...
Molecular diodes based on conjugated diblock co-oligomers.
Ng, Man-Kit; Lee, Dong-Chan; Yu, Luping
2002-10-09
This report describes synthesis and characterization of a molecular diode based upon a diblock conjugated oligomer system. This system consists of two conjugated blocks with opposite electronic demand. The molecular structure exhibits a built-in electronic asymmetry, much like a semiconductor p-n junction. Electrical measurements by scanning tunneling spectroscopy (STS) clearly revealed a pronounced rectifying effect. Definitive proof for the molecular nature of the rectifying effect in this conjugated diblock molecule is provided by control experiments with a structurally similar reference compound.
Quiet Clean Short-haul Experimental Engine (QCSEE) over-the-wing control system design report
NASA Technical Reports Server (NTRS)
1977-01-01
A control system incorporating a digital electronic control was designed for the over-the-wing engine. The digital electronic control serves as the primary controlling element for engine fuel flow and core compressor stator position. It also includes data monitoring capability, a unique failure indication and corrective action feature, and optional provisions for operating with a new type of servovalve designed to operate in response to a digital-type signal and to fail with its output device hydraulically locked into position.
Harle, Christopher A.; Lipori, Gloria; Hurley, Robert W.
2016-01-01
Introduction: Advances in health policy, research, and information technology have converged to increase the electronic collection and use of patient-reported outcomes (PROs). Therefore, it is important to share lessons learned in implementing PROs in research information systems. Case Description: The purpose of this case study is to describe a novel information system for electronic PROs and lessons learned in implementing that system to support research in an academic health center. The system incorporates freely available and commercial software and involves clinical and research workflows that support the collection, transformation, and research use of PRO data. The software and processes that comprise the system serve three main functions, (i) collecting electronic PROs in clinical care, (ii) integrating PRO data with non-patient generated clinical data, and (iii) disseminating data to researchers through the institution’s research informatics infrastructure, including the i2b2 (Informatics for Integrating Biology and the Bedside) system. Strategies: Our successful design and implementation was driven by three overarching strategies. First, we selected and implemented multiple interfaced technologies to support PRO collection, management, and research use. Second, we aimed to use standardized approaches to measuring PROs, sending PROs between systems, and disseminating PROs. Finally, we focused on using technologies and processes that aligned with existing clinical research information management strategies within our organization. Conclusion: These experiences and lessons may help future implementers and researchers enhance the scale and sustainable use of systems for research use of PROs. PMID:27563683
Harle, Christopher A; Lipori, Gloria; Hurley, Robert W
2016-01-01
Advances in health policy, research, and information technology have converged to increase the electronic collection and use of patient-reported outcomes (PROs). Therefore, it is important to share lessons learned in implementing PROs in research information systems. The purpose of this case study is to describe a novel information system for electronic PROs and lessons learned in implementing that system to support research in an academic health center. The system incorporates freely available and commercial software and involves clinical and research workflows that support the collection, transformation, and research use of PRO data. The software and processes that comprise the system serve three main functions, (i) collecting electronic PROs in clinical care, (ii) integrating PRO data with non-patient generated clinical data, and (iii) disseminating data to researchers through the institution's research informatics infrastructure, including the i2b2 (Informatics for Integrating Biology and the Bedside) system. Our successful design and implementation was driven by three overarching strategies. First, we selected and implemented multiple interfaced technologies to support PRO collection, management, and research use. Second, we aimed to use standardized approaches to measuring PROs, sending PROs between systems, and disseminating PROs. Finally, we focused on using technologies and processes that aligned with existing clinical research information management strategies within our organization. These experiences and lessons may help future implementers and researchers enhance the scale and sustainable use of systems for research use of PROs.
Management of waste electrical and electronic equipment in Romania: A mini-review.
Ciocoiu, Carmen Nadia; Colesca, Sofia Elena; Rudăreanu, Costin; Popescu, Maria-Loredana
2016-02-01
Around the world there are growing concerns for waste electrical and electronic equipment. This is motivated by the harmful effects of waste electrical and electronic equipment on the environment, but also by the perspectives of materials recovery. Differences between countries regarding waste electrical and electronic equipment management are notable in the European Union. Romania is among the countries that have made significant efforts to comply with European Union regulations, but failed reaching the collection target. The article presents a mini review of the waste electrical and electronic equipment management system in Romania, based on legislation and policy documents, statistical data, research studies and reports published by national and international organisations. The article debates subjects like legislative framework, the electrical and electronic equipment Romanian market, the waste electrical and electronic equipment collection system, waste electrical and electronic equipment processing and waste electrical and electronic equipment behaviour. The recast of the European directive brings new challenges to national authorities and to other stakeholders involved in the waste electrical and electronic equipment management. Considering the fact that Romania has managed a collection rate of roughly 1 kg capita(-1) in the last years, the new higher collection targets established by the waste electrical and electronic equipment Directive offer a serious challenge for the management system. Therefore, another aim of the article is to highlight the positive and negative aspects in the Romanian waste electrical and electronic equipment field, in order to identify the flows that should be corrected and the opportunities that could help improve this system to the point of meeting the European standards imposed by the European Directive. © The Author(s) 2015.
Navigational Heads-Up Display: Will a Shipboard Augmented Electronic Navigation System Sink or Swim?
2015-03-01
of Management and Budget, Paperwork Reduction Project (0704-0188) Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank) I 2. REPORT DATE I 3. REPORT...empirical results demonstrate the viability of using such a system in an operation environment and support a need for further research and development...empirical results demonstrate the viability of using such a system in an operation environment and support a need for further research and development
Technology for large space systems: A bibliography with indexes (supplement 11)
NASA Technical Reports Server (NTRS)
1985-01-01
This bibliography contains 539 abstracts of reports, articles and other documents introduced into the NASA scientific and technical information system between January 1, 1984 and December 31, 1984. Abstracts are arranged in the following categories: systems; analysis and design techniques; structural concepts; structural and thermal analysis; structural dynamics and control; electronics; advanced materials; assembly concepts; propulsion; and miscellaneous. Subject, personal author, corporate source, contract number, report number, and accession number indexes are listed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anastasi, A.; Basti, A.; Bedeschi, F.
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be providedmore » by the laser and the stability of the calibration system components.« less
Evaluating acceptance of an electronic data management system at a tertiary care institution.
Young, Wendy; Klima, George; Isaac, Winston
2011-01-01
This research reports on satisfaction with the introduction of an electronic document management system in a tertiary hospital environment. A buffet of training and familiarization options were offered: one-on-one training, open house, drop-in, e-learning, classroom training, and self-study. It was found that professions differ in their pattern of satisfaction with training and they also differ in their satisfaction with both the usefulness and the ease of use of the system. Satisfaction among administrators was highest and that among nurses lowest. There was an association between attendance at the open house event and satisfaction with the system.
Apollo experience report: Electronic systems test program accomplishments and results
NASA Technical Reports Server (NTRS)
Ohnesorge, T. E.
1972-01-01
A chronological record is presented of the Electronic Systems Test Program from its conception in May 1963 to December 1969. The original concept of the program, which was primarily a spacecraft/Manned Space Flight Network communications system compatibility and performance evaluation, is described. The evolution of these concepts to include various levels of test detail, as well as systems level design verification testing, is discussed. Actual implementation of these concepts is presented, and the facility to support the program is described. Test results are given, and significant contributions to the lunar landing mission are underlined. Plans for modifying the facility and the concepts, based on Apollo experience, are proposed.
75 FR 27182 - Energy Conservation Program: Web-Based Compliance and Certification Management System
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-14
... Conservation Program: Web-Based Compliance and Certification Management System AGENCY: Office of Energy... certification reports to the Department of Energy (DOE) through an electronic Web-based tool, the Compliance and... following means: 1. Compliance and Certification Management System (CCMS)--via the Web portal: http...
ERIC Educational Resources Information Center
Brady, Melanie; Seli, Helena; Rosenthal, Jane
2013-01-01
Recent research suggests that clickers (electronic feedback devices) influence metacognition. This article reports qualitative findings from a quasi-experimental study comparing clickers and low technology polling. We sought to establish how clickers influence metacognition and whether differences exist in how each response system influences…
ERIC Educational Resources Information Center
May, Donald M.; And Others
The minicomputer-based Computerized Diagnostic and Decision Training (CDDT) system described combines the principles of artificial intelligence, decision theory, and adaptive computer assisted instruction for training in electronic troubleshooting. The system incorporates an adaptive computer program which learns the student's diagnostic and…
Operation Of The X-29A Digital Flight-Control System
NASA Technical Reports Server (NTRS)
Chacon, Vince; Mcbride, David
1990-01-01
Report reviews program of testing and evaluation of digital flight-control system for X-29A airplane, with emphasis on operation during tests. Topics include design of system, special electronic testing equipment designed to aid in daily operations, and aspects of testing, including detection of faults.
Active pharmacovigilance in China: recent development and future perspectives.
Li, Xinling; Li, Haona; Deng, Jianxiong; Zhu, Feng; Liu, Ying; Chen, Wenge; Yue, Zhihua; Ren, Xuequn; Xia, Jielai
2018-04-10
The effectiveness of active pharmacovigilance depends on the specific methods adopted and the work patterns put into place. Over the past few years, much attention has been paid to the importance of implementing such systems in China. However, less has been done to evaluate the state of implementation and future needs of such systems. This paper reviews China's recent approaches to active pharmacovigilance by examining: (1) information collected from scientific articles and the websites of the China Food and Drug Administration and the China National Center for Adverse Drug Reaction Monitoring, (2) information available on China's spontaneous reporting systems (SRS) and active pharmacovigilance system, and (3) annual reports and internal reports on this subject. Areas that improved most meaningfully for China's active pharmacovigilance in recent years appear to include: (1) quicker reporting and more intelligent scanning methods for adverse drug reactions (ADRs), (2) the use of pharmacovigilance approaches to mine electronic hospital records, and (3) the development of integrated systems including the China Hospital Pharmacovigilance System and China Sentinel Hospital Alliance Program. Not only has the national online SRS system provided a platform for passive pharmacovigilance, it has also become an important platform for various explorations of active pharmacovigilance in China. Quick reporting and intelligent scanning of ADRs, facilitated by automated ADR detection based on electronic hospital records, have accelerated to capabilities for active pharmacovigilance. The outcomes of the programs, such as the China Hospital Pharmacovigilance System and China Sentinel Hospital Alliance Program, usher in a new era for China's active pharmacovigilance. These are particularly important to bridge the information system of sentinel hospitals and ADR research centers, but gaps remain. Thus, much work needs to be done before a high-level active pharmacovigilance system is sufficiently mature to ensure drug safety in the country.
Hennenfent, Andrew; DelVento, Vito; Davies-Cole, John; Johnson-Clarke, Fern
2017-03-01
To enhance the early detection of emerging infectious diseases and bioterrorism events using companion animal-based surveillance. Washington, DC, small animal veterinary facilities (n=17) were surveyed to determine interest in conducting infectious disease surveillance. Using these results, an electronic-based online reporting system was developed and launched in August 2015 to monitor rates of canine influenza, canine leptospirosis, antibiotic resistant infections, canine parvovirus, and syndromic disease trends. Nine of the 10 facilities that responded expressed interest conducting surveillance. In September 2015, 17 canine parvovirus cases were reported. In response, a campaign encouraging regular veterinary preventative care was launched and featured on local media platforms. Additionally, during the system's first year of operation it detected 5 canine leptospirosis cases and 2 antibiotic resistant infections. No canine influenza cases were reported and syndromic surveillance compliance varied, peaking during National Special Security Events. Small animal veterinarians and the general public are interested in companion animal disease surveillance. The system described can serve as a model for establishing similar systems to monitor disease trends of public health importance in pet populations and enhance biosurveillance capabilities. Copyright © 2017 Elsevier B.V. All rights reserved.
1974-01-01
also makes the Government vulner- able to upward price pressures by the selected supplier and induces design stagnation. % • The potential benefit of...following modifications: 1. It should specifically permit consideration of changes that are of benefit to the contractor and not detrimen- tal to...vali- dated by experience, that competition throughout the electronic-system life-cycle process will, on the whole, yield great benefits in
Guffey, Patrick; Szolnoki, Judit; Caldwell, James; Polaner, David
2011-07-01
Current incident reporting systems encourage retrospective reporting of morbidity and mortality and have low participation rates. A near miss is an event that did not cause patient harm, but had the potential to. By tracking and analyzing near misses, systems improvements can be targeted appropriately, and future errors may be prevented. An electronic, web based, secure, anonymous reporting system for anesthesiologists was designed and instituted at The Children's Hospital, Denver. This portal was compared to an existing hospital incident reporting system. A total of 150 incidents were reported in the first 3 months of operation, compared to four entered in the same time period 1 year ago. An anesthesia-specific anonymous near-miss reporting system, which eases and facilitates data entry and can prospectively identify processes and practices that place patients at risk, was implemented at a large, academic, freestanding children's hospital. This resulted in a dramatic increase in reported events and provided data to target and drive quality and process improvement. © 2011 Blackwell Publishing Ltd.
Biomaterials-Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, Meredith; Bettinger, Christopher J.
2012-01-01
Advanced polymeric biomaterials continue to serve as a cornerstone of new medical technologies and therapies. The vast majority of these materials, both natural and synthetic, interact with biological matter without direct electronic communication. However, biological systems have evolved to synthesize and employ naturally-derived materials for the generation and modulation of electrical potentials, voltage gradients, and ion flows. Bioelectric phenomena can be interpreted as potent signaling cues for intra- and inter-cellular communication. These cues can serve as a gateway to link synthetic devices with biological systems. This progress report will provide an update on advances in the application of electronically active biomaterials for use in organic electronics and bio-interfaces. Specific focus will be granted to the use of natural and synthetic biological materials as integral components in technologies such as thin film electronics, in vitro cell culture models, and implantable medical devices. Future perspectives and emerging challenges will also be highlighted. PMID:23184740
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shadangi, Asit Ku., E-mail: asitshad@iopb.res.in; Rout, G. C., E-mail: gcr@iopb.res.in
2015-05-15
We report here a microscopic model study of ultrasonic attenuation in f-electron systems based on Periodic Anderson Model in which Coulomb interaction is considered within a mean-field approximation for a weak interaction. The Phonon is coupled to the conduction band and f-electrons. The phonon Green's function is calculated by Zubarev's technique of the Green's function method. The temperature dependent ultrasonic attenuation co-efficient is calculated from the imaginary part of the phonon self-energy in the dynamic and long wave length limit. The f-electron occupation number is calculated self-consistently in paramagnetic limit of Coulomb interaction. The effect of the Coulomb interaction onmore » ultrasonic attenuation is studied by varying the phonon coupling parameters to the conduction and f-electrons, hybridization strength, the position of f-level and the Coulomb interaction Strength. Results are discussed on the basis of experimental results.« less
Electronic and Vibrational Coherence in Charge-Transfer Reactions
NASA Astrophysics Data System (ADS)
Scherer, Norbert
1996-03-01
The ultrafast dynamics associated with optically-induced intervalence charge-transfer reactions in solution and protein environments are reported. These studies include the Fe^(II)-Fe^(III) MMCT complex Prussian blue and the mixed valence dimer (CN)_5Ru^(II)CNRuRu^(III)(NH_3)_5. The protein systems include blue copper proteins and the bacterial photosynthetic reaction center. The experimental approaches include photon echo, wavelength-resolved pump-probe and anisotropy measurements performed with 12-16fs duration optical pulses. Complicated time-domain waveforms reflect the several different p[rocesses and time scales for relaxation of coherences (both electronic and vibrational) and populations within these systems. The photon echo and anisotropy results probe electronic coherence and dephasing prior to back electron transfer. Wavelength-resolved pump-probe results reveal vibrational modes coupled to the CT-coordinate as well as formation of new product states or vibrational cooling in the ground state following back electron transfer.
Code of Federal Regulations, 2011 CFR
2011-01-01
... home computer systems of an employee; or (4) Whether the information is active or inactive. (k) Record... (e.g., e-mail, databases, spreadsheets, PowerPoint presentations, electronic reporting systems... information is stored or located, including network servers, desktop or laptop computers and handheld...
Elastic electron scattering by ethyl vinyl ether
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khakoo, M. A.; Hong, L.; Kim, B.
2010-02-15
We report measured and calculated results for elastic scattering of low-energy electrons by ethyl vinyl ether (ethoxyethene), a prototype system for studying indirect dissociative attachment processes that may play a role in DNA damage. The integral cross section displays the expected {pi}{sup *} shape resonance. The agreement between the calculated and measured cross sections is generally good.
JPRS Report, Science & Technology, Europe & Latin America
1987-08-12
there is significant international interest in this today. Going beyond the original applications the thermoluminescent dosimeters ( TLD ) developed...manufacturing; --Applications in the health and teaching sectors; —Correspondence management; -- Electronic mail. The competitive advantages of the multimedia...objective of the MOSES project is to make the multimedia electronic documentation system much more powerful than its paper counterpart. To achieve
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-30
... submitted electronically on a weekly basis through a NMFS-approved electronic reporting system by the dealer... metric tons (mt) dressed weight (dw) (149,914 lb dw) of non-blacknose SCS quota from the Atlantic region... lb dw), the Atlantic hammerhead shark management group quota is 27.1 metric tons (mt) dressed weight...
ERIC Educational Resources Information Center
Filinger, Ronald H.; Hall, Paul W.
Because large scale individualized learning systems place excessive demands on conventional means of producing audiovisual software, electronic image generation has been investigated as an alternative. A prototype, experimental device, Scanimate-500, was designed and built by the Computer Image Corporation. It uses photographic, television, and…
NASA Tech Briefs, May 1995. Volume 19, No. 5
NASA Technical Reports Server (NTRS)
1995-01-01
This issue features an resource report on Jet Propulsion Laboratory and a special focus on advanced composites and plastics. It also contains articles on electronic components and circuits, electronic systems, physical sciences, computer programs, mechanics, machinery, manufacturing and fabrication, mathematics and information sciences, and life sciences. This issue also contains a supplement on federal laboratory test and measurements.
Laboratory Information Management System Chain of Custody: Reliability and Security
Tomlinson, J. J.; Elliott-Smith, W.; Radosta, T.
2006-01-01
A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of automation and of data reliability can vary, and FDA- and EPA-compliant electronic signatures and system security are rare. PMID:17671623
SPAD electronics for high-speed quantum communications
NASA Astrophysics Data System (ADS)
Bienfang, Joshua C.; Restelli, Alessandro; Migdall, Alan
2011-01-01
We discuss high-speed electronics that support the use of single-photon avalanche diodes (SPADs) in gigahertz singlephoton communications systems. For InGaAs/InP SPADs, recent work has demonstrated reduced afterpulsing and count rates approaching 500 MHz can be achieved with gigahertz periodic-gating techniques designed to minimize the total avalanche charge to less than 100 fC. We investigate afterpulsing in this regime and establish a connection to observations using more conventional techniques. For Si SPADs, we report the benefits of improved timing electronics that enhance the temporal resolution of Si SPADs used in a free-space quantum key distribution (QKD) system operating in the GHz regime. We establish that the effects of count-rate fluctuations induced by daytime turbulent scintillation are significantly reduced, benefitting the performance of the QKD system.
1993-10-01
Concern about wandering patients and infant abduction on the part of hospitals has sparked renewed interest in Electronic Article Surveillance (EAS) systems. Such systems had their origins in department stores and libraries where they are almost universally used. They also have applications in hospitals for preventing the theft of supplies and equipment. A number of companies provide EAS products for the health care field. How do you select the system that is best for your needs? "Talk to users. Pick out a number of profit and non-profit hospitals to get their views," advises Ted Algaier, vice president, marketing and sales, Innovative Control Systems, Inc., Waukesha, WI. "Examine the history of the company or vendor to determine if it understands the health care market and find out if the product really works." In this report, we'll review a number of EAS systems currently on the market, and present information on how they work, how effective they are, and costs involved. Also included are comments from users who have installed such systems.
Lacson, Ronilda; O'Connor, Stacy D; Sahni, V Anik; Roy, Christopher; Dalal, Anuj; Desai, Sonali; Khorasani, Ramin
2016-07-01
Optimal critical test result communication is a Joint Commission national patient safety goal and requires documentation of closed-loop communication among care providers in the medical record. Electronic alert notification systems can facilitate an auditable process for creating alerts for transmission and acknowledgement of critical test results. We evaluated the impact of a patient safety initiative with an alert notification system on reducing critical results lacking documented communication, and assessed potential overuse of the alerting system for communicating results. We implemented an alert notification system-Alert Notification of Critical Results (ANCR)-in January 2010. We reviewed radiology reports finalised in 2009-2014 which lacked documented communication between the radiologist and another care provider, and assessed the impact of ANCR on the proportion of such reports with critical findings, using trend analysis over 10 semiannual time periods. To evaluate potential overuse of ANCR, we assessed the proportion of reports with non-critical results among provider-communicated reports. The proportion of reports with critical results among reports without documented communication decreased significantly over 4 years (2009-2014) from 0.19 to 0.05 (p<0.0001, Cochran-Armitage trend test). The proportion of provider-communicated reports with non-critical results remained unchanged over time before and after ANCR implementation (0.20 to 0.15, p=0.45, Cochran-Armitage trend test). A patient safety initiative with an alert notification system reduced the proportion of critical results among reports lacking documented communication between care providers. We observed no change in documented communication of non-critical results, suggesting the system did not promote overuse. Future studies are needed to evaluate whether such systems prevent subsequent patient harm. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
A front-end readout Detector Board for the OpenPET electronics system
NASA Astrophysics Data System (ADS)
Choong, W.-S.; Abu-Nimeh, F.; Moses, W. W.; Peng, Q.; Vu, C. Q.; Wu, J.-Y.
2015-08-01
We present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is ``time stamped'' by a time-to-digital converter (TDC) implemented inside the FPGA . This digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.
A front-end readout Detector Board for the OpenPET electronics system
Choong, W. -S.; Abu-Nimeh, F.; Moses, W. W.; ...
2015-08-12
Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, whichmore » allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.« less
NASA Astrophysics Data System (ADS)
Kim, Jung Rae
Bioelectrochemical system such as microbial fuel cells (MFCs) and microbial electrolysis cell are an emerging technology which converts biodegradable organic matter to electrical energy or hydrogen using a biofilm on the electrode as the biocatalyst. It has recently been shown that waste-to-energy technology based on MFC can treat organic contaminant in domestic or industrial wastewater and simultaneously produce electricity. The maximum power density increased up to 1kW/m3 based on reactor volume. Bioelectrochemical systems may reduce the energy consumption for wastewater treatment by replacing energy intensive aeration of present treatment systems, while generate electrical energy from waste. In addition, the biomass production in MFCs has been reported to be 10-50% of conventional wastewater treatment, leading to reduce environmental impact and disposal costs. Various electrochemically active bacteria metabolize biodegradable organic compounds then discharge electrons to an extracellular electron acceptor for bacterial respiration. These bacteria also transfer electrons to electrodes by direct electron transfer, electron mediators or shuttles, and electrically conductive nanowires. Investigation of bacterial electron transport mechanisms may improve understanding of the biomaterial involved and metabolic pathways as well as improving power from MFCs. Biofuel cell systems require interdisciplinary research ranging from electrochemistry, microbiology, material science and surface chemistry to engineering such as reactor design, operation and modelling. Collaboration within each study and integration of systems might increase the performance and feasibility of BES process for sustainable energy.
Carrell, David S.; Halgrim, Scott; Tran, Diem-Thy; Buist, Diana S. M.; Chubak, Jessica; Chapman, Wendy W.; Savova, Guergana
2014-01-01
The increasing availability of electronic health records (EHRs) creates opportunities for automated extraction of information from clinical text. We hypothesized that natural language processing (NLP) could substantially reduce the burden of manual abstraction in studies examining outcomes, like cancer recurrence, that are documented in unstructured clinical text, such as progress notes, radiology reports, and pathology reports. We developed an NLP-based system using open-source software to process electronic clinical notes from 1995 to 2012 for women with early-stage incident breast cancers to identify whether and when recurrences were diagnosed. We developed and evaluated the system using clinical notes from 1,472 patients receiving EHR-documented care in an integrated health care system in the Pacific Northwest. A separate study provided the patient-level reference standard for recurrence status and date. The NLP-based system correctly identified 92% of recurrences and estimated diagnosis dates within 30 days for 88% of these. Specificity was 96%. The NLP-based system overlooked 5 of 65 recurrences, 4 because electronic documents were unavailable. The NLP-based system identified 5 other recurrences incorrectly classified as nonrecurrent in the reference standard. If used in similar cohorts, NLP could reduce by 90% the number of EHR charts abstracted to identify confirmed breast cancer recurrence cases at a rate comparable to traditional abstraction. PMID:24488511
Electronic intermodal supply chain manifest field operational test evaluation draft final report
DOT National Transportation Integrated Search
2002-12-01
This report presents the results of a 2.5 year freight ITS evaluation of an air cargo security and logistics system which was deployed at OHare and JFK international airports. In September 1999, the Federal Highway Administration (FHWA) and the Fe...
77 FR 6803 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-09
... report, ``Hidden Tragedy: Underreporting of Workplace Injuries and Illnesses,'' indicating ``that work....'' Based in part on the report's results, Congress allocated funds for NIOSH to conduct a follow-up study using NIOSH's occupational supplement to the National Electronic Injury Surveillance System (NEISS-Work...
ERIC Educational Resources Information Center
Hermes, James
2003-01-01
Describes the Student and Visitor Exchange Information System (SEVIS). SEVIS legislation requires institutions to report electronically foreign students' identities and addresses, as well as visa and other information. Reports on updates to the legislation that are being enacted as a result of the September 11, 2001 terrorist attacks. Includes…
40 CFR 1068.501 - How do I report emission-related defects?
Code of Federal Regulations, 2011 CFR
2011-07-01
...) AIR POLLUTION CONTROLS GENERAL COMPLIANCE PROVISIONS FOR ENGINE PROGRAMS Reporting Defects and... components or systems containing the following components: (i) Electronic control units, aftertreatment... control information labels. Note however, that § 1068.101(a)(1) prohibits the sale of engines/equipment...
Hans, Parminder K; Gray, Carolyn Steele; Gill, Ashlinder; Tiessen, James
2018-03-01
Aim This qualitative study investigates how the Electronic Patient-Reported Outcome (ePRO) mobile application and portal system, designed to capture patient-reported measures to support self-management, affected primary care provider workflows. The Canadian health system is facing an ageing population that is living with chronic disease. Disruptive innovations like mobile health technologies can help to support health system transformation needed to better meet the multifaceted needs of the complex care patient. However, there are challenges with implementing these technologies in primary care settings, in particular the effect on primary care provider workflows. Over a six-week period interdisciplinary primary care providers (n=6) and their complex care patients (n=12), used the ePRO mobile application and portal to collaboratively goal-set, manage care plans, and support self-management using patient-reported measures. Secondary thematic analysis of focus groups, training sessions, and issue tracker reports captured user experiences at a Toronto area Family Health Team from October 2014 to January 2015. Findings Key issues raised by providers included: liability concerns associated with remote monitoring, increased documentation activities due to a lack of interoperability between the app and the electronic patient record, increased provider anxiety with regard to the potential for the app to disrupt and infringe upon appointment time, and increased demands for patient engagement. Primary care providers reported the app helped to focus care plans and to begin a collaborative conversation on goal-setting. However, throughout our investigation we found a high level of provider resistance evidenced by consistent attempts to shift the app towards fitting with existing workflows rather than adapting much of their behaviour. As health systems seek innovative and disruptive models to better serve this complex patient population, provider change resistance will need to be addressed. New models and technologies cannot be disruptive in an environment that is resisting change.
Single-chip microprocessor that communicates directly using light.
Sun, Chen; Wade, Mark T; Lee, Yunsup; Orcutt, Jason S; Alloatti, Luca; Georgas, Michael S; Waterman, Andrew S; Shainline, Jeffrey M; Avizienis, Rimas R; Lin, Sen; Moss, Benjamin R; Kumar, Rajesh; Pavanello, Fabio; Atabaki, Amir H; Cook, Henry M; Ou, Albert J; Leu, Jonathan C; Chen, Yu-Hsin; Asanović, Krste; Ram, Rajeev J; Popović, Miloš A; Stojanović, Vladimir M
2015-12-24
Data transport across short electrical wires is limited by both bandwidth and power density, which creates a performance bottleneck for semiconductor microchips in modern computer systems--from mobile phones to large-scale data centres. These limitations can be overcome by using optical communications based on chip-scale electronic-photonic systems enabled by silicon-based nanophotonic devices. However, combining electronics and photonics on the same chip has proved challenging, owing to microchip manufacturing conflicts between electronics and photonics. Consequently, current electronic-photonic chips are limited to niche manufacturing processes and include only a few optical devices alongside simple circuits. Here we report an electronic-photonic system on a single chip integrating over 70 million transistors and 850 photonic components that work together to provide logic, memory, and interconnect functions. This system is a realization of a microprocessor that uses on-chip photonic devices to directly communicate with other chips using light. To integrate electronics and photonics at the scale of a microprocessor chip, we adopt a 'zero-change' approach to the integration of photonics. Instead of developing a custom process to enable the fabrication of photonics, which would complicate or eliminate the possibility of integration with state-of-the-art transistors at large scale and at high yield, we design optical devices using a standard microelectronics foundry process that is used for modern microprocessors. This demonstration could represent the beginning of an era of chip-scale electronic-photonic systems with the potential to transform computing system architectures, enabling more powerful computers, from network infrastructure to data centres and supercomputers.