Sample records for electronically cleansed 3d

  1. Assessment of post-contamination treatments affecting different bonding stages to dentin

    PubMed Central

    Elkassas, Dina; Arafa, Abla

    2016-01-01

    Objectives: To assess the effect of cleansing treatments following saliva and blood contamination at different bonding stages to dentin. Materials and Methods: Labial surfaces of 168 permanent maxillary central incisors were ground flat exposing superficial dentin. Specimens were divided into: uncontaminated control (A), contamination after etching (B), contamination after adhesive application (C), contamination after adhesive polymerization (D). Groups were further subdivided according to cleansing treatments into: rinsing (B1, C1, D1), re-etching (B2, D3), sodium hypochlorite application (B3), ethyl alcohol application (C2), acetone application (C3), rinsing and rebonding (D2), re-etching and rebonding (D4). Composite microcylinders were bonded to treated substrates and shear loaded micro-shear bond strength (μSBS) until failure and treated surfaces were examined with scanning electron microscope. Debonded surfaces were classified as adhesive, cohesive or mixed failure. The data were analyzed using one-way ANOVA and Tukey's post hoc test. Results: The μSBS values were ranked as follow; Group B: A > B3 > B2 > B1 > B, Group C: A > C3 > C2 > C1 > C, Group D: A > D4 > D1 = D2 ≥ D3. Debonded surfaces showed adhesive failure in Group B while cohesive failure in Groups C and D. Conclusions: Cleansing treatments differ according to bonding step; re-etching then rebonding suggested if etched substrate or polymerized adhesive were contaminated while acetone application decontaminated affected unpolymerized adhesive. PMID:27403048

  2. Standardization of skin cleansing in vivo: part I. Development of an Automated Cleansing Device (ACiD).

    PubMed

    Sonsmann, F K; Strunk, M; Gediga, K; John, C; Schliemann, S; Seyfarth, F; Elsner, P; Diepgen, T L; Kutz, G; John, S M

    2014-05-01

    To date, there are no legally binding requirements concerning product testing in cosmetics. This leads to various manufacturer-specific test methods and absent transparent information on skin cleansing products. A standardized in vivo test procedure for assessment of cleansing efficacy and corresponding barrier impairment by the cleaning process is needed, especially in the occupational context where repeated hand washing procedures may be performed at short intervals. For the standardization of the cleansing procedure, an Automated Cleansing Device (ACiD) was designed and evaluated. Different smooth washing surfaces of the equipment for ACiD (incl. goat hair, felt, felt covered with nitrile caps) were evaluated regarding their skin compatibility. ACiD allows an automated, fully standardized skin washing procedure. Felt covered with nitrile as washing surface of the rotating washing units leads to a homogenous cleansing result and does not cause detectable skin irritation, neither clinically nor as assessed by skin bioengineering methods (transepidermal water loss, chromametry). Automated Cleansing Device may be useful for standardized evaluation of the cleansing effectiveness and parallel assessment of the corresponding irritancy potential of industrial skin cleansers. This will allow objectifying efficacy and safety of industrial skin cleansers, thus enabling market transparency and facilitating rational choice of products. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Systems and methods for data quality control and cleansing

    DOEpatents

    Wenzel, Michael; Boettcher, Andrew; Drees, Kirk; Kummer, James

    2016-05-31

    A method for detecting and cleansing suspect building automation system data is shown and described. The method includes using processing electronics to automatically determine which of a plurality of error detectors and which of a plurality of data cleansers to use with building automation system data. The method further includes using processing electronics to automatically detect errors in the data and cleanse the data using a subset of the error detectors and a subset of the cleansers.

  4. Informatics in Radiology: Dual-Energy Electronic Cleansing for Fecal-Tagging CT Colonography

    PubMed Central

    Kim, Se Hyung; Lee, June-Goo; Yoshida, Hiroyuki

    2013-01-01

    Electronic cleansing (EC) is an emerging technique for the removal of tagged fecal materials at fecal-tagging computed tomographic (CT) colonography. However, existing EC methods may generate various types of artifacts that severely impair the quality of the cleansed CT colonographic images. Dual-energy fecal-tagging CT colonography is regarded as a next-generation imaging modality. EC that makes use of dual-energy fecal-tagging CT colonographic images promises to be effective in reducing cleansing artifacts by means of applying the material decomposition capability of dual-energy CT. The dual-energy index (DEI), which is calculated from the relative change in the attenuation values of a material at two different photon energies, is a reliable and effective indicator for differentiating tagged fecal materials from various types of tissues on fecal-tagging CT colonographic images. A DEI-based dual-energy EC scheme uses the DEI to help differentiate the colonic lumen—including the luminal air, tagged fecal materials, and air-tagging mixture—from the colonic soft-tissue structures, and then segments the entire colonic lumen for cleansing of the tagged fecal materials. As a result, dual-energy EC can help identify partial-volume effects in the air-tagging mixture and inhomogeneous tagging in residual fecal materials, the major causes of EC artifacts. This technique has the potential to significantly improve the quality of EC and promises to provide images of a cleansed colon that are free of the artifacts commonly observed with conventional single-energy EC methods. © RSNA, 2013 PMID:23479680

  5. A 25% tannic acid solution as a root canal irrigant cleanser: a scanning electron microscope study.

    PubMed

    Bitter, N C

    1989-03-01

    A scanning electron microscope was used to evaluate the cleansing properties of a 25% tannic acid solution on the dentinal surface in the pulp chamber of endodontically prepared teeth. This was compared with the amorphous smear layer of the canal with the use of hydrogen peroxide and sodium hypochlorite solution as an irrigant. The tannic acid solution removed the smear layer more effectively than the regular cleansing agent.

  6. Effect of saliva contamination and cleansing solutions on the bond strengths of self-etch adhesives to dentin.

    PubMed

    Sheikh, Huma; Heymann, Harald O; Swift, Edward J; Ziemiecki, Thomas L; Ritter, André V

    2010-12-01

    This study determined the effect of saliva contamination and cleansing solutions on microtensile bond strengths of self-etch adhesives to dentin. Seventy-five human molars were ground flat to expose mid-coronal dentin and randomly assigned to five groups (N = 15): no contamination, saliva contamination without cleansing, saliva and cleansing with water, saliva and cleansing with 2% chlorhexidine, and saliva and cleansing with 5% sodium hypochlorite. One-third of the specimens in each group of 15 were bonded with Adper Prompt L-Pop (all-in-one self-etch adhesive; 3M ESPE, St. Paul, MN, USA), one-third with Adper Easy Bond (all-in-one self-etch adhesive; 3M ESPE), and one-third with Clearfil SE Bond (self-etch primer system; Kuraray America, New York, NY, USA). Specimens were restored with composite and processed for microtensile bond strength testing (5-6 rods/tooth). Mean bond strengths ranged from 17.3 MPa for Adper Prompt L-Pop after water cleansing to 69.3 MPa for Clearfil SE Bond after water cleansing. For all three adhesives, there was no statistically significant difference in bond strengths between the saliva contaminated group, the cleansing groups, and the no contamination groups. Neither saliva nor the cleansing solutions adversely affected bond strengths of the self-etch adhesive systems. © 2010, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2010, WILEY PERIODICALS, INC.

  7. Cleanliness in the Root Canal System: An Scanning Electron Microscopic Evaluation of Manual and Automated Instrumentation using 4% Sodium Hypochlorite and EDTA (Glyde File Prep)―An in vitro Study

    PubMed Central

    Meshram, GK

    2010-01-01

    ABSTRACT Aim : To assess the cleaning efficacy of manual and automated instrumentation using 4% sodium hypochlorite singly and in combination with Glyde file Prep as root canal irrigant. Methodology : The study utilized 40 extracted human permanent premolars with single, straight and fully formed root. The teeth were then divided into four groups of ten each, Group I and II were prepared by manual instruments with 4% sodium hypochlorite used as irrigant singly [Group I] or in combination with Glyde file prep. Group III and IV were prepared by automated instruments at 250 rpm with 4% sodium hypochlorite as irrigant singly [Group III] and in combination with glyde file prep [Group IV] automated instrumentation. After completion of the root canal preparation the canal, teeth were prepared for SEM examination. These photomicrographs were qualitatively evaluated using criteria. Overall cleanliness, presence or absence of the smear layer, presence or absence of the debris, patency of the opening of dentinal tubules. Results : When comparing the cleansing efficacy of manual and automated instrumentation using 4% sodium hypochlorite better cleansing was there with manual instrumentation. When comparing the cleansing efficacy of manual and automated instrumentation using combination regime cleansing is better with automated instrumentation. When comparing the cleansing efficacy of manual instrumentation using 4% sodium hypochlorite singly and in combination with EDTA, the combination regime led to better cleansing. When comparing the cleansing efficacy of automated instrumentation using 4% sodium hypochlorite singly and in combination regime lead to better cleansing. Conclusion : Neither of instrumentation technique, nor irrigating regimes were capable of providing a completely clean canal. Automated instrumentation with a combination of sodium hypochlorite & EDTA resulted the best cleansing efficacy. PMID:27616839

  8. Impact of 4.0% chlorhexidine cord cleansing on the bacteriologic profile of the newborn umbilical stump in rural Sylhet District, Bangladesh: a community-based, cluster-randomized trial.

    PubMed

    Mullany, Luke C; Saha, Samir K; Shah, Rasheduzzaman; Islam, Mohammad Shahidul; Rahman, Mostafiz; Islam, Maksuda; Talukder, Radwanur Rahman; El Arifeen, Shams; Darmstadt, Gary L; Baqui, Abdullah H

    2012-05-01

    Randomized trials from South Asia indicate umbilical cord chlorhexidine cleansing reduces mortality and omphalitis. No community-based data are available on bacteriological profile of the cord, early neonatal colonization dynamics, or impact of cord cleansing on colonizing organisms. Such data could clarify the design of scaled chlorhexidine interventions. Umbilical swabs were collected at home (days 1, 3, 6) after birth from infants participating in a trial of 3 cord-care regimens (no chlorhexidine, single cleansing, multiple cleansing) in Sylhet, Bangladesh. Overall and organism-specific positivity rates were estimated by cord-care regimen and by day of collection. Between September 2008 and October 2009, 1923 infants contributed 5234 umbilical swabs. Positivity rate was high (4057 of 5234, 77.5%) and varied substantially across groups. Immediate (day 1) reductions in cord colonization were observed in single- (prevalence rate ratio = 0.75, 95% confidence interval: 0.70-0.81) and multiple- (prevalence rate ratio = 0.71, 95% confidence interval: 0.66-0.77) cleansing groups. Reductions persisted and increased in magnitude through day 6 only if babies received multiple applications. On days 1, 3, and 6, respectively, multiple cleansing consistently reduced invasive organisms such as Escherichia coli (49%, 64%, and 42% lower), Klebsiella pneumoniae (46%, 53%, and 33% lower), and Staphylococcus aureus (34%, 84%, and 85% lower). Cord cleansing with 4.0% chlorhexidine immediately after birth reduces overall and organism-specific colonization of the stump. Reductions are greater and sustained longer with daily cleansing through the first week of life, suggesting that programs promoting chlorhexidine cleansing should favor multiple over single applications.

  9. Scalable, High-performance 3D Imaging Software Platform: System Architecture and Application to Virtual Colonoscopy

    PubMed Central

    Yoshida, Hiroyuki; Wu, Yin; Cai, Wenli; Brett, Bevin

    2013-01-01

    One of the key challenges in three-dimensional (3D) medical imaging is to enable the fast turn-around time, which is often required for interactive or real-time response. This inevitably requires not only high computational power but also high memory bandwidth due to the massive amount of data that need to be processed. In this work, we have developed a software platform that is designed to support high-performance 3D medical image processing for a wide range of applications using increasingly available and affordable commodity computing systems: multi-core, clusters, and cloud computing systems. To achieve scalable, high-performance computing, our platform (1) employs size-adaptive, distributable block volumes as a core data structure for efficient parallelization of a wide range of 3D image processing algorithms; (2) supports task scheduling for efficient load distribution and balancing; and (3) consists of a layered parallel software libraries that allow a wide range of medical applications to share the same functionalities. We evaluated the performance of our platform by applying it to an electronic cleansing system in virtual colonoscopy, with initial experimental results showing a 10 times performance improvement on an 8-core workstation over the original sequential implementation of the system. PMID:23366803

  10. Low-dose dual-energy electronic cleansing for fecal-tagging CT Colonography

    NASA Astrophysics Data System (ADS)

    Cai, Wenli; Zhang, Da; Lee, June-Goo; Yoshida, Hiroyuki

    2013-03-01

    Dual-energy electronic cleansing (DE-EC) provides a promising means for cleansing the tagged fecal materials in fecaltagging CT colonography (CTC). However, the increased radiation dose due to the double exposures in dual-energy CTC (DE-CTC) scanning is a major limitation for the use of DE-EC in clinical practice. The purpose of this study was to develop and evaluate a low-dose DE-EC scheme in fecal-tagging DE-CTC. In this study, a custom-made anthropomorphic colon phantom, which was filled with simulated tagged materials by non-ionic iodinated contrast agent (Omnipaque iohexol, GE Healthcare), was scanned by a dual-source CT scanner (SOMATON Definition Flash, Siemens Healthcare) at two photon energies: 80 kVp and 140 kVp with nine different tube current settings ranging from 12 to 74 mAs for 140 kVp, and then reconstructed by soft-tissue reconstruction kernel (B30f). The DE-CTC images were subjected to a low-dose DE-EC scheme. First, our image-space DE-CTC denoising filter was applied for reduction of image noise. Then, the noise-reduced images were processed by a virtual lumen tagging method for reduction of partial volume effect and tagging inhomogeneity. The results were compared with the registered CTC images of native phantom without fillings. Preliminary results showed that our low-dose DE-EC scheme achieved the cleansing ratios, defined by the proportion of the cleansed voxels in the tagging mask, between 93.18% (12 mAs) and 96.62% (74 mAs). Also, the soft-tissue preservation ratios, defined by the proportion of the persevered voxels in the soft-tissue mask, were maintained in the range between 94.67% and 96.41%.

  11. Electronic cleansing for CT colonography using spectral-driven iterative reconstruction

    NASA Astrophysics Data System (ADS)

    Nasirudin, Radin A.; Näppi, Janne J.; Hironaka, Toru; Tachibana, Rie; Yoshida, Hiroyuki

    2017-03-01

    Dual-energy computed tomography is used increasingly in CT colonography (CTC). The combination of computer-aided detection (CADe) and dual-energy CTC (DE-CTC) has high clinical value, because it can detect clinically significant colonic lesions automatically at higher accuracy than does conventional single-energy CTC. While CADe has demonstrated its ability to detect small polyps, its performance is highly dependent on several factors, including the quality of CTC images and electronic cleansing (EC) of the images. The presence of artifacts such as beam hardening and image noise in ultra-low-dose CTC can produce incorrectly cleansed colon images that severely degrade the detection performance of CTC for small polyps. Also, CADe methods are very dependent on the quality of input images and the information about different tissues in the colon. In this work, we developed a novel method to calculate EC images using spectral information from DE-CTC data. First, the ultra-low dose dual-energy projection data obtained from a CT scanner are decomposed into two materials, soft tissue and the orally administered fecal-tagging contrast agent, to detect the location and intensity of the contrast agent. Next, the images are iteratively reconstructed while gradually removing the presence of tagged materials from the images. Our preliminary qualitative results show that the method can cleanse the contrast agent and tagged materials correctly from DE-CTC images without affecting the appearance of surrounding tissue.

  12. [Comparison of the cleansing effect of two micromotor-driven endodontic hand pieces. I. Comparison ot the cleansing effect of the two handpieces].

    PubMed

    Bartha, K; Rocca, J P

    1993-11-01

    The aim of the study was to assess the cleansing-effect of two endodontic handpieces (Excalibur, W & H; MM 1400 Micro Méga) in root canals that were previously manually prepared, and treated with chlor-(Neomagnol) and citric acid containing solutions. The analyses were performed by scanning electron microscope (SEM). The elimination of the Smear Layer (SL) with Neomagnol was not successful with either of the two handpieces. The cleansing of the Superficial Debris (SD) with Neomagnol activated by MM 1400 was significantly more effective in the apical (p < 0.05) and in the middle (p < 0.01) third of the root-canal, than by Excalibur. In contrast, SL was better eliminated by Excalibur using citric acid, significant differences--when compared with MM 1400--could be seen in the middle third (p < 0.05) of the root-canal. The handpieces seem to have their own specific characteristics: thus MM 1400 was better in eliminating the SD (used with Neomagnol), while Excalibur was superior in eliminating the SL (used with citric acid).

  13. "Embodiment as procedures: Physical cleansing changes goal priming effects": Correction to Dong and Lee (2017).

    PubMed

    2017-06-01

    Reports an error in "Embodiment as procedures: Physical cleansing changes goal priming effects" by Ping Dong and Spike W. S. Lee ( Journal of Experimental Psychology: General , 2017[Apr], Vol 146[4], 592-605). In the article, the following F-value and p-values in the Results section of Experiment 3 were set incorrectly: The p -value p =.925 should be p =.922. The F - and p -values F (1, 201)=.011, p =.916 should be F (1, 201) .014, p = .906. (The following abstract of the original article appeared in record 2017-14922-010.) Physical cleansing reduces the influence of numerous psychological experiences, such as guilt from immoral behavior, dissonance from free choice, and good/bad luck from winning/losing. How do these domain-general effects occur? We propose an integrative account of cleansing as an embodied procedure of psychological separation. By separating physical traces from a physical target object (e.g., detaching dirt from hands), cleansing serves as the embodied grounding for the separation of psychological traces from a psychological target object (e.g., dissociating prior experience from the present self). This account predicts that cleansing reduces the accessibility of psychological traces and their consequences for judgments and behaviors. Testing these in the context of goal priming, we find that wiping one's hands (vs. not) decreases the mental accessibility (Experiment 1), behavioral expression (Experiment 2), and judged importance (Experiments 3-4) of previously primed goals (e.g., achievement, saving, fitness). But if a goal is primed after cleansing, its importance gets amplified instead (Experiment 3). Based on the logic of moderation-of-process, an alternative manipulation that psychologically separates a primed goal from the present self produces the same effects, but critically, the effects vanish once people wipe their hands clean (Experiment 4), consistent with the notion that cleansing functions as an embodied procedure of psychological separation. These findings have implications for the flexibility of goal pursuit. More broadly, our procedural perspective generates novel predictions about the scope and mechanisms of cleansing effects and may help integrate embodied and related phenomena. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. Unfinished Business: The Sons of Iraq and Political Reconciliation

    DTIC Science & Technology

    2010-03-25

    out in the National Strategy for Victory in Iraq. 3 of sectarian cleansing in Baghdad, population centric tactics by CF, and increased... cleansed neighborhoods of one sect or the other as the two sides vied for power. Shia families in Sunni dominated areas packed up as many belongings...and Selected Neighborhoods18 8 The Shia controlled government reinforced JAM’s ethnic cleansing operations through a denial of essential

  15. Analysis of dispersive interactions at polymer/TiAlN interfaces by means of dynamic force spectroscopy.

    PubMed

    Wiesing, M; de Los Arcos, T; Gebhard, M; Devi, A; Grundmeier, G

    2017-12-20

    The structural and electronic origins of the interactions between polycarbonate and sputter deposited TiAlN were analysed using a combined electron and force spectroscopic approach. Interaction forces were measured by means of dynamic force spectroscopy and the surface polarizability was analysed by X-ray photoelectron valence band spectroscopy. It could be shown that the adhesive interactions between polycarbonate and TiAlN are governed by van der Waals forces. Different surface cleansing and oxidizing treatments were investigated and the effect of the surface chemistry on the force interactions was analysed. Intense surface oxidation resulted in a decreased adhesion force by a factor of two due to the formation of a 2 nm thick Ti 0.21 Al 0.45 O surface oxide layer. The origin of the residual adhesion forces caused by the mixed Ti 0.21 Al 0.45 O surface oxide was clarified by considering the non-retarded Hamaker coefficients as calculated by Lifshitz theory, based on optical data from Reflection Electron Energy Loss Spectroscopy. This disclosed increased dispersion forces of Ti 0.21 Al 0.45 O due to the presence of Ti(iv) ions and related Ti 3d band optical transitions.

  16. Evaluation of mild skin cleansers.

    PubMed

    Wortzman, M S

    1991-01-01

    Each person makes the decision of how best to care for his or her own skin. Among the prime concerns, especially for facial skin, is the type of dirt, debris, or make-up to be removed. In most cases, all products do an adequate job in the removal of dirt; if not, the washing techniques can be modified to accomplish the task at hand. What cannot be controlled are the adverse side effects inherent in the use of that product. These adverse properties include damages to the barrier function of the skin; increased susceptibility to environmental sources of irritation and sensitization; frank irritation responses, such as erythema and edema; and reduction of the cosmetic qualities of the skin, such as degree of moisture and smoothness. Part of the problem is that most of these changes are subtle, occurring slowly over time. Often, the association of these problems with the use of a particular facial cleansing regimen is overlooked. The typical woman uses as many as 10 to 15 facial cosmetic and cleansing products each day, making the identification of a problem even more difficult. It is important to identify the risks associated with individual products and with product categories in general. Although the identification of a safe group of products to use for facial cleansing is desirable, the results of this investigation indicate that there are no simple answers. It has been assumed that because moisturizing cream formulations are routinely safe and mild in general use, a cleansing product in the same general form would share these attributes. We can see from the results in Table 2 and Figures 2, 3, 5, 7, and 9 that cleansing creams are not uniformly superior to cleansing bars in the key attributes that are used to evaluate mildness. In each evaluation there were individual cleansing creams that demonstrated statistically weaker performance than did cleansing bars in general. As a group, cleansing creams did well in the cosmetic categories of dryness and texture but surprisingly poorly in such indicators of clinical safety as erythema and TEWL. Further evaluation of the components of the facial-washing regimens proposed by the manufacturers of many of the cleansing-cream products involved the direct comparison of a cleansing cream against that same product used with an alcohol-based toning product. In all cases, the addition of alcohol-based products to the cleaning protocol reduced the cosmetic and clinical safety of the regimen (see Table 2 and Figures 3, 5, 7, and 9).(ABSTRACT TRUNCATED AT 400 WORDS)

  17. Atmospheric Hydroxyl Radical Production from Electronically Excited NO2 and H2O

    NASA Astrophysics Data System (ADS)

    Li, Shuping; Matthews, Jamie; Sinha, Amitabha

    2008-03-01

    Hydroxyl radicals are often called the “detergent” of the atmosphere because they control the atmosphere’s capacity to cleanse itself of pollutants. Here, we show that the reaction of electronically excited nitrogen dioxide with water can be an important source of tropospheric hydroxyl radicals. Using measured rate data, along with available solar flux and atmospheric mixing ratios, we demonstrate that the tropospheric hydroxyl contribution from this source can be a substantial fraction (50%) of that from the traditional O(1D) + H2O reaction in the boundary-layer region for high solar zenith angles. Inclusion of this chemistry is expected to affect modeling of urban air quality, where the interactions of sunlight with emitted NOx species, volatile organic compounds, and hydroxyl radicals are central in determining the rate of ozone formation.

  18. Atmospheric hydroxyl radical production from electronically excited NO2 and H2O.

    PubMed

    Li, Shuping; Matthews, Jamie; Sinha, Amitabha

    2008-03-21

    Hydroxyl radicals are often called the "detergent" of the atmosphere because they control the atmosphere's capacity to cleanse itself of pollutants. Here, we show that the reaction of electronically excited nitrogen dioxide with water can be an important source of tropospheric hydroxyl radicals. Using measured rate data, along with available solar flux and atmospheric mixing ratios, we demonstrate that the tropospheric hydroxyl contribution from this source can be a substantial fraction (50%) of that from the traditional O(1D) + H2O reaction in the boundary-layer region for high solar zenith angles. Inclusion of this chemistry is expected to affect modeling of urban air quality, where the interactions of sunlight with emitted NOx species, volatile organic compounds, and hydroxyl radicals are central in determining the rate of ozone formation.

  19. Vaginal preparation with antiseptic solution before cesarean section for preventing postoperative infections.

    PubMed

    Haas, David M; Morgan, Sarah; Contreras, Karenrose

    2014-12-21

    Cesarean delivery is one of the most common surgical procedures performed by obstetricians. Infectious morbidity after cesarean delivery can have a tremendous impact on the postpartum woman's return to normal function and her ability to care for her baby. Despite the widespread use of prophylactic antibiotics, postoperative infectious morbidity still complicates cesarean deliveries. To determine if cleansing the vagina with an antiseptic solution before a cesarean delivery decreases the risk of maternal infectious morbidities, including endometritis and wound complications. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (10 December 2014). We included randomized and quasi-randomized trials assessing the impact of vaginal cleansing immediately before cesarean delivery with any type of antiseptic solution versus a placebo solution/standard of care on post-cesarean infectious morbidity. We independently assessed eligibility and quality of the studies. Seven trials randomizing 2816 women (2635 analyzed) evaluated the effects of vaginal cleansing (all with povidone-iodine) on post-cesarean infectious morbidity. The risk of bias was generally low, with the quality of most of the studies being high. Vaginal preparation immediately before cesarean delivery significantly reduced the incidence of post-cesarean endometritis from 8.3% in control groups to 4.3% in vaginal cleansing groups (average risk ratio (RR) 0.45, 95% confidence interval (CI) 0.25 to 0.81, seven trials, 2635 women). The risk reduction was particularly strong for women who were already in labor at the time of the cesarean delivery (7.4% in the vaginal cleansing group versus 13.0% in the control group; RR 0.56, 95% CI 0.34 to 0.95, three trials, 523 women) and for women with ruptured membranes (4.3% in the vaginal cleansing group versus 17.9% in the control group; RR 0.24, 95% CI 0.10 to 0.55, three trials, 272 women). No other outcomes realized statistically significant differences between the vaginal cleansing and control groups. No adverse effects were reported with the povidone-iodine vaginal cleansing.The quality of the evidence using GRADE was low for post-cesarean endometritis, moderate for postoperative fever, and low for wound infection. Vaginal preparation with povidone-iodine solution immediately before cesarean delivery reduces the risk of postoperative endometritis. This benefit is particularly realized for women undergoing cesarean delivery, who are already in labor or who have ruptured membranes. As a simple, generally inexpensive intervention, providers should consider implementing preoperative vaginal cleansing with povidone-iodine before performing cesarean deliveries.

  20. Surface characteristics of clinically used dental implant screws

    NASA Astrophysics Data System (ADS)

    Han, Myung-Ju; Choe, Han-Cheol; Chung, Chae-Heon

    2005-12-01

    Surface alteration of implant screws after function may be associated with mechanicalffailure. This type of metal fatigue appears to be the most common cause of structural failure. The purpose of this study was to evaluate surface alteration of implant screws after function through an examination of used and unused implant screws via scanning electron microscopy (SEM). In this study, abutment screws (Steri-oss, 3i, USA), gold retaining screws (3i, USA), and titanium retaining screws (3i, USA) were retrieved from patients, New, unused abutment, and retaining screws were prepared for a control group. Each of the old, used screws was retrieved with a screwdriver. The retrieved implant complex of a Steri-oss system was also prepared for this study. SEM investigation and energy dispersive spectroscopy (EDS) analysis of the abutment and retaining screws were then performed, as well as SEM investigation of a cross-sectioned sample of the retrieved implant complex in the case of new, unused implant screws, as-manufactured circumferential grooves were regularly examined and screw threads were sharply maintained. Before ultrasonic cleansing of old, used implant screws, there was a large amount of debris accumulation and corrosion products. After ultrasonic cleansing of old, used implant screws, circumferential grooves were examined were found to be randomly deepened and scratching increased. Also, dull screw fhreads were observed. More surface alterations after function were observed in titanium screws than in gold screws. Furthermore, more surface alteration was observed when the screws were retrieved with a driver than without a driver. These surface alterations after function may result in screw instability. Regular cleansing and exchange of screws is therefore recommended. We also recommend the use of gold screws over titanium screws, and careful manipulation of the driver.

  1. Automated virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Hunt, Gordon W.; Hemler, Paul F.; Vining, David J.

    1997-05-01

    Virtual colonscopy (VC) is a minimally invasive alternative to conventional fiberoptic endoscopy for colorectal cancer screening. The VC technique involves bowel cleansing, gas distension of the colon, spiral computed tomography (CT) scanning of a patient's abdomen and pelvis, and visual analysis of multiplanar 2D and 3D images created from the spiral CT data. Despite the ability of interactive computer graphics to assist a physician in visualizing 3D models of the colon, a correct diagnosis hinges upon a physician's ability to properly identify small and sometimes subtle polyps or masses within hundreds of multiplanar and 3D images. Human visual analysis is time-consuming, tedious, and often prone to error of interpretation.We have addressed the problem of visual analysis by creating a software system that automatically highlights potential lesions in the 2D and 3D images in order to expedite a physician's interpretation of the colon data.

  2. Performance evaluation of multi-material electronic cleansing for ultra-low-dose dual-energy CT colonography

    NASA Astrophysics Data System (ADS)

    Tachibana, Rie; Kohlhase, Naja; Näppi, Janne J.; Hironaka, Toru; Ota, Junko; Ishida, Takayuki; Regge, Daniele; Yoshida, Hiroyuki

    2016-03-01

    Accurate electronic cleansing (EC) for CT colonography (CTC) enables the visualization of the entire colonic surface without residual materials. In this study, we evaluated the accuracy of a novel multi-material electronic cleansing (MUMA-EC) scheme for non-cathartic ultra-low-dose dual-energy CTC (DE-CTC). The MUMA-EC performs a wateriodine material decomposition of the DE-CTC images and calculates virtual monochromatic images at multiple energies, after which a random forest classifier is used to label the images into the regions of lumen air, soft tissue, fecal tagging, and two types of partial-volume boundaries based on image-based features. After the labeling, materials other than soft tissue are subtracted from the CTC images. For pilot evaluation, 384 volumes of interest (VOIs), which represented sources of subtraction artifacts observed in current EC schemes, were sampled from 32 ultra-low-dose DE-CTC scans. The voxels in the VOIs were labeled manually to serve as a reference standard. The metric for EC accuracy was the mean overlap ratio between the labels of the reference standard and the labels generated by the MUMA-EC, a dualenergy EC (DE-EC), and a single-energy EC (SE-EC) scheme. Statistically significant differences were observed between the performance of the MUMA/DE-EC and the SE-EC methods (p<0.001). Visual assessment confirmed that the MUMA-EC generated less subtraction artifacts than did DE-EC and SE-EC. Our MUMA-EC scheme yielded superior performance over conventional SE-EC scheme in identifying and minimizing subtraction artifacts on noncathartic ultra-low-dose DE-CTC images.

  3. Bowel preparation for colonoscopy with magnesium sulphate and low-volume polyethylene glycol.

    PubMed

    Tepeš, Bojan; Mlakar, Dominika N; Metličar, Tanja

    2014-06-01

    Patient compliance with bowel cleansing procedures represents one of the most objectionable aspects of colonoscopy. Adverse reactions to the purgative may result in failure to complete the preparation, inadequate visualization of the colon, polyp and even carcinoma miss rate and unwillingness to attend a follow-up colonoscopy. The primary objective of the study was to evaluate the effectiveness of bowel cleansing with magnesium sulphate and low-volume polyethylene glycol (PEG) with electrolytes. The second objective was to evaluate whether bowel cleansing was better in participants scheduled for morning colonoscopies or afternoon colonoscopies. Magnesium sulphate mineral water (2 l) and 2 l of low-volume PEG and electrolytes solution were used as our bowel cleansing protocol. A total of 13 914 participants, who participated in the Slovenian colorectal cancer screening programme in the period between 2009 and 2011, were included. Excellent bowel preparation was achieved in 11 484 (82.61%) participants; 1894 (13.62%) participants had good bowel preparation, 439 (3.16%) participants had fair bowel preparation and 85 (0.61%) participants had poor bowel preparation. Better results were achieved in the afternoon colonoscopies and in younger participant groups (P<0.001). No serious side effects of bowel cleansing were reported. This is the first study to use magnesium sulphate mineral water and PEG plus electrolytes for bowel cleansing. We found excellent bowel cleansing in 82.61% participants and in more participants if colonoscopy was performed in the afternoon.

  4. Characterisation of faecal protease activity in irritable bowel syndrome with diarrhoea: origin and effect of gut transit.

    PubMed

    Tooth, David; Garsed, Klara; Singh, Gulzar; Marciani, Luca; Lam, Ching; Fordham, Imogen; Fields, Annie; Banwait, Rawinder; Lingaya, Melanie; Layfield, Robert; Hastings, Maggie; Whorwell, Peter; Spiller, Robin

    2014-05-01

    Faecal serine proteases (FSPs) may play a role in irritable bowel syndrome with diarrhoea (IBS-D), but their origin is unclear. We aimed to structurally characterise them and define the impact of colonic cleansing and transit time. Faecal samples were obtained from 30 healthy volunteers (HV) and 79 patients with IBS-D participating in a trial of ondansetron versus placebo. Colonic transit was measured using radio-opaque markers. Samples were also obtained from 24 HV before and after colonic cleansing with the osmotic laxative MoviPrep. FSPs were purified from faecal extracts using benzamidine-Sepharose affinity chromatography. SDS-PAGE profiled components were identified using trypsinolysis and tandem mass spectrometry. Functional protease activity in faecal extracts was measured using a colorimetric assay based on the proteolysis of azo-casein. Protein analysis identified the most abundant FSPs as being of human origin and probably derived from pancreatic juice. Functional assays showed increased faecal protease (FP) and amylase in patients with IBS-D compared with HV. Those with higher amylase had significantly higher FP and greater anxiety. FP activity correlated negatively with whole gut transit in patients with IBS-D (Spearman r=-0.32, p=0.005) and HV (r=-0.55, p=0.014). Colon cleansing caused a significant rise in FP activity in HV from a baseline of median (IQR) 253 (140-426) to 1031 (435-2296), levels similar to those seen in patients with IBS-D. FSP activity correlated positively with days/week with urgency. The most abundant FSPs are of human origin. Rapid transit through the colon and/or decreased (possibly bacterial) proteolytic degradation increases their faecal concentration and could contribute to visceral hypersensitivity in patients with IBS-D. NCT00745004.

  5. A prospective audit of the efficacy, safety, and acceptability of low-volume polyethylene glycol (2 L) versus standard volume polyethylene glycol (4 L) versus magnesium citrate plus stimulant laxative as bowel preparation for colonoscopy.

    PubMed

    Kelly, Nicholas Michael; Rodgers, Colin; Patterson, Neil; Jacob, Sudheer George; Mainie, Inder

    2012-08-01

    High-quality video colonoscopy requires adequate preparation of the bowel to ensure both adequate procedure completion rates and polyp detection rates. We sought to examine our practice to determine which bowel preparation cleansed most effectively in our patients. A prospective audit of the efficacy, safety, and acceptability of low-volume polyethylene glycol (2-L Moviprep; Norgine Pharmaceuticals) versus standard volume polyethylene glycol (4-L KleanPrep; Norgine Pharmaceuticals) versus magnesium citrate (Citramag; Sanochemia UK Ltd.) plus stimulant laxative as bowel preparation for colonoscopy. District General Hospital. Patients attending for day case colonoscopy. Not applicable. Overall cleansing grades of preparations used: patient compliance, taste, and acceptability. A prospective audit of patient experience of taking bowel preparation and blinded colonic scoring assessment of bowel cleansing of each of the tested regimes. A total of 258 (female,138; 53.5%) patients were recruited, 91 in the KleanPrep group (F:45, 49.5%), 86 patients in the Moviprep group (female, 45; 52.3%), and 81 in the Senna/Citramag group (female, 44; 54.3%). Significantly more patients were unable to take the prescribed dose of KleanPrep when compared with the other 2 regimes (19.6%; P<0.0001 vs. Moviprep; P<0.0001 vs. Senna/Citramag). A total of 45.65% of patients reported KleanPrep as tasting unpleasant. This was significantly more than both Moviprep (10.47%; P=0.008) and Senna/Citramag (9.88%; P<0.0001). The overall cleansing efficacy across the 3 groups (those with grades A or B) was 73.9%, 74.5%, and 86.5% for KleanPrep, Moviprep, and Senna/Citramag, respectively. In this series Senna/Citramag proved significantly better at bowel cleansing than KleanPrep (P<0.05) and it showed a trend toward better cleansing when compared with Moviprep (P=0.08). Nonrandomized trial. Split-dosing regime for morning and afternoon lists may have confounded results. In summary, low-volume PEG (Moviprep) and Senna/Citramag combination were better tolerated than large volume PEG with Senna/Citramag providing superior mucosal cleansing.

  6. MiraLAX-Gatorade Bowel Prep vs. GoLytely Prior to Screening Colonoscopy: An Endoscopic Database Study in a Community Hospital

    PubMed Central

    Shieh, Frederick K.; Gunaratnam, Naresh; Mohamud, Sagal O.; Schoenfeld, Philip

    2012-01-01

    Background Polyethylene Glycol-3350 without electrolytes (MiraLAX®; Schering-Plough Healthcare Products Inc.) + a carbohydrate-electrolyte solution (Gatorade; PepsiCo Inc.) + bisacodyl is frequently used for bowel cleansing, although limited data quantifies its efficacy and safety. No prior studies have assessed this in a community setting or with PM-only dosing, which is still used frequently. Aim To compare the frequency of excellent/good/fair/poor bowel cleansing with PM-only dosing of MiraLAX®-Gatorade-bisacodyl vs. 4L GoLytely®. Methods This is a retrospective endoscopic database analysis of ≥ 50 year old average-risk individuals with a normal screening colonoscopy at a community hospital and ambulatory endoscopy center. Data was extracted for the last four months when 4L GoLytely® was the preferred bowel purgative and the first 4 months when 238g MiraLAX® in 64 ounces Gatorade and four 5-mg bisacodyl tablets became the preferred purgative. All patients used PM-only dosing of bowel purgative. Results 778 subjects [GoLytely® (n=395) vs. MiraLAX® + Gatorade + bisacodyl (n=383)] were identified. Patients who took the MiraLAX® bowel preparation were more likely to achieve an excellent/good bowel cleansing compared to patients taking the GoLytely® preparation (93.3% vs. 89.3%, respectively; p = 0.048). However, when only ASA Class I patients are studied, there was no difference in frequency of excellent/good bowel cleansing (91.1% vs 93.6%, respectively; p = 0.498). No serious adverse events were identified. An excellent/good bowel cleansing was strongly associated with a recommendation for repeat colonoscopy in 10 years compared to patients with a fair cleansing [OR = 28.01; 95% CI: 13.96-56.19]. Conclusions The MiraLAX® + Gatorade + bisacodyl combination produces similar rates of excellent/good bowel cleansing as compared to GoLytely® in most average-risk individuals undergoing colonoscopy for CRC screening in a community setting. PMID:23060223

  7. Indirect latex glove contamination and its inhibitory effect on vinyl polysiloxane polymerization.

    PubMed

    Kimoto, Katsuhiko; Tanaka, Kinya; Toyoda, Minoru; Ochiai, Kent T

    2005-05-01

    The inhibitory effect of indirect latex contamination on the polymerization of vinyl polysiloxane (VPS) impression material has been previously reported. However, the transfer of specific elements that cause inhibition has not been confirmed, nor has the removal of such contaminants been reported. This study examined the surfaces of materials commonly used in restorative procedures that were contaminated by indirect latex glove contact and then evaluated for inhibition of polymerization of VPS. The effect of selected cleansing procedures was then studied. Four experimental groups (n = 8) were prepared: (1) clean vinyl gloves (control), (2) clean gingival retraction cords (control), (3) contaminated vinyl gloves, and (4) contaminated gingival retraction cord. Microscopic evaluation of the appearance and the characterization of surface particulate contamination were performed for each. Three cleansing protocols were then evaluated for efficacy in cleaning vinyl glove surfaces contaminated by latex contact (n = 10): (1) brushing with water, (2) brushing with soap/rinsing with water, (3) cleansing with rubbing alcohol. The subsequent degree of VPS polymerization inhibition was evaluated subjectively. A chi-square test was used for data analysis (alpha=.05). Particulate sulfur elements and sulfur-chloride compounds were present on the contaminated substrates. None of the 3 cleansing procedures eliminated polymerization inhibition (P =.33). Residual elemental sulfur remained on all tested surfaces. Particulate sulfur and sulfur-chloride compounds were identified as the particulate contamination that resulted in polymerization inhibition of the tested VPS dental impression material. Removal of these contaminants from the tested vinyl gloves and gingival retraction cord was not possible with the 3 cleansing protocols tested in this study.

  8. The Bali STD/AIDS study: association between vaginal hygiene practices and STDs among sex workers.

    PubMed

    Reed, B D; Ford, K; Wirawan, D N

    2001-02-01

    To assess the association between genital cleansing practices and the prevalence of sexually transmitted diseases and of sexual health knowledge among female sex workers in Bali, Indonesia. Low priced commercial sex workers (CSWs) participated in the Bali STD/AIDS Study, a 3 year educational project evaluating the effect of education on the subsequent use of condoms and the prevalence of STDs and AIDS. Structured interviews, genital evaluation, laboratory evaluation for STDs, and treatment were performed. Vaginal cleansing characteristics including frequency, type, and reasons for use, were evaluated. Associations between these characteristics and the presence of bacterial and viral genital infections were assessed. Of 625 female sex workers evaluated between May and July 1998, 99.1% used substances, such as soap and toothpaste, to clean the vagina at least daily, with 69.3% performing this after each intercourse. The women using such cleansers after each client did not differ from those using them once or less daily in education, AIDS and condom use knowledge, time working as a CSW, or number of clients in the previous day. However, they were younger than those using vaginal cleansers daily or less, and reported lower condom usage in the past week. Several genital symptoms, such as discoloured discharge and odour, were reported less by women with the highest frequency of vaginal cleanser use. Prevalence of genital infections in this population of women was substantial, with bacterial infections more prevalent than viral infections. Infections were not associated with the type of cleanser used, using a genital cleanser on the day of examination, or using a cleanser after each client versus daily or less, except for candida colonisation, which was more prevalent in women cleansing after each client (OR=1.87, 95% CI 1.21, 2.90). However, symptomatic candida vulvovaginitis (positive culture plus presence of symptoms) was not associated with the prevalence of genital cleansing. Women using genital cleansing in part for "infection avoidance" (39.7%) were more likely to have heard of STDs and AIDS, but were less knowledgeable about these infections, compared with women not citing this reason for genital cleansing. Commercial sex workers in low priced brothels in Bali have a high rate of genital infections, with lower rates of viral compared with bacterial infections. Genital cleansers, on a daily or after each intercourse schedule, are used routinely. Although genital cleansing after each intercourse was associated with fewer genital symptoms, the prevalence of STDs did not differ significantly based on this frequency, and the women's knowledge of STDs and AIDS was less than that of women cleansing less often. The effect of genital cleansing in general on STD and AIDS prevalence could not be assessed in this population owing to the lack of a non-cleansing cohort. Further study to elucidate the effect of vaginal cleansing practices on STD prevalence and resistance is needed.

  9. 3% Amuchina is as effective as the 50% concentration in the prevention of exit-site infection in children on chronic peritoneal dialysis.

    PubMed

    Grosman, Mònica D; Mosquera, Vanesa M; Hernandez, Maria G; Agostini, Silvana; Adragna, Marta; Sojo, Ernesto T

    2005-01-01

    In a previous communication, we demonstrated that, in the prevention of exit-site infection (ESI) in children, the cleansing agent 50% Amuchina (electrolytic chloroxidizer. Amuchina SpA, Genoa, Italy) is more effective than 10% povidone iodine and as effective as 4% chlorhexidine, but with fewer adverse secondary effects. In the present study, we assessed, in an Argentine pediatric population, whether Amuchina 3% is as effective as Amuchina 50% in preventing ESI in children on chronic peritoneal dialysis. In an open-label, single-center prospective study, 27 children (mean age: 7.2 years; range: 1.7-17 years) used 3% Amuchina as a cleansing agent for the daily care of a healthy exit site. Of the 27 children, 14 were switched from 50% Amuchina to 3% Amuchina, and 13 were using the 3% Amuchina for the first time. The control group consisted of 18 patients who had previously used 50% Amuchina as a cleansing agent. We followed the recommendations of the International Society for Peritoneal Dialysis with regard to exit-site care, which include keeping the cleansing agent out of the sinus and rinsing the exit site with sterile water. Amuchina was used from the first post-implantation care of the exit site. No adverse secondary effects were seen with the use of Amuchina at either concentration. Patients using 3% Amuchina presented an ESI rate similar to that of patients using Amuchina 50%. The cost of 3% Amuchina was significantly lower than that of the 50% concentration, and it was even lower than the cost for 10% povidone iodine or 4% chlorhexidine. Although more research trials are needed to assess the efficacy of 3% Amuchina, we conclude that 3% Amuchina is the best and most cost-effective cleansing agent for the daily care of a healthy exit site in children on chronic peritoneal dialysis.

  10. A robust sebum, oil, and particulate pollution model for assessing cleansing efficacy of human skin.

    PubMed

    Peterson, G; Rapaka, S; Koski, N; Kearney, M; Ortblad, K; Tadlock, L

    2017-06-01

    With increasing concerns over the rise of atmospheric particulate pollution globally and its impact on systemic health and skin ageing, we have developed a pollution model to mimic particulate matter trapped in sebum and oils creating a robust (difficult to remove) surrogate for dirty, polluted skin. To evaluate the cleansing efficacy/protective effect of a sonic brush vs. manual cleansing against particulate pollution (trapped in grease/oil typical of human sebum). The pollution model (Sebollution; sebum pollution model; SPM) consists of atmospheric particulate matter/pollution combined with grease/oils typical of human sebum. Twenty subjects between the ages of 18-65 were enrolled in a single-centre, cleansing study comparisons between the sonic cleansing brush (normal speed) compared to manual cleansing. Equal amount of SPM was applied to the centre of each cheek (left and right). Method of cleansing (sonic vs. manual) was randomized to the side of the face (left or right) for each subject. Each side was cleansed for five-seconds using the sonic cleansing device with sensitive brush head or manually, using equal amounts of water and a gel cleanser. Photographs (VISIA-CR, Canfield Imaging, NJ, USA) were taken at baseline (before application of the SPM), after application of SPM (pre-cleansing), and following cleansing. Image analysis (ImageJ, NIH, Bethesda, MD, USA) was used to quantify colour intensity (amount of particulate pollutants on the skin) using a scale of 0 to 255 (0 = all black pixels; 255 = all white pixels). Differences between the baseline and post-cleansing values (pixels) are reported as the amount of SPM remaining following each method of cleansing. Using a robust cleansing protocol to assess removal of pollutants (SPM; atmospheric particulate matter trapped in grease/oil), the sonic brush removed significantly more SPM than manual cleansing (P < 0.001). While extreme in colour, this pollution method easily allows assessment of efficacy through image analysis. © 2016 The Authors. International Journal of Cosmetic Science published by John Wiley & Sons Ltd on behalf of Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  11. Deep multi-spectral ensemble learning for electronic cleansing in dual-energy CT colonography

    NASA Astrophysics Data System (ADS)

    Tachibana, Rie; Näppi, Janne J.; Hironaka, Toru; Kim, Se Hyung; Yoshida, Hiroyuki

    2017-03-01

    We developed a novel electronic cleansing (EC) method for dual-energy CT colonography (DE-CTC) based on an ensemble deep convolution neural network (DCNN) and multi-spectral multi-slice image patches. In the method, an ensemble DCNN is used to classify each voxel of a DE-CTC image volume into five classes: luminal air, soft tissue, tagged fecal materials, and partial-volume boundaries between air and tagging and those between soft tissue and tagging. Each DCNN acts as a voxel classifier, where an input image patch centered at the voxel is generated as input to the DCNNs. An image patch has three channels that are mapped from a region-of-interest containing the image plane of the voxel and the two adjacent image planes. Six different types of spectral input image datasets were derived using two dual-energy CT images, two virtual monochromatic images, and two material images. An ensemble DCNN was constructed by use of a meta-classifier that combines the output of multiple DCNNs, each of which was trained with a different type of multi-spectral image patches. The electronically cleansed CTC images were calculated by removal of regions classified as other than soft tissue, followed by a colon surface reconstruction. For pilot evaluation, 359 volumes of interest (VOIs) representing sources of subtraction artifacts observed in current EC schemes were sampled from 30 clinical CTC cases. Preliminary results showed that the ensemble DCNN can yield high accuracy in labeling of the VOIs, indicating that deep learning of multi-spectral EC with multi-slice imaging could accurately remove residual fecal materials from CTC images without generating major EC artifacts.

  12. Comparative evaluation of enamel abrasivity by toothbrush and velcro: An in vitro scanning electron microscope study

    PubMed Central

    Ojha, Saroj Kumar; Javdekar, Sadashiv Bhaskar; Dhir, Sangeeta

    2015-01-01

    Context: Plaque control has been shown to be pivotal in maintaining the optimal periodontal health. Mechanical plaque control is the most popular option for establishing the optimal oral health. Toothbrushes have been the novel tool for mechanical cleansing. However, the abrasive potential of the toothbrushes on the enamel surface is an area in gray. Aims: The aim of this in vitro study is to evaluate the abrasivity of the toothbrush versus the velcro fasteners. Materials and Methods: The mounted teeth of both the groups were subjected to abrasion test, and the tooth surfaces were observed for the possible abrasions from the oscillating strokes (toothbrush) and frictional contacts (hook and loop velcro) and examined under the scanning electron microscope. Results: Comparative assessment of both velcro (hook and loop) and toothbrush bristles did not reveal any evidence of abrasion on the tooth specimens. Conclusions: Veclro fasteners are safe and qualitatively at par to the manual toothbrush for their efficacy and efficiency in teeth cleansing PMID:26229264

  13. Half doses of PEG-ES and senna vs. high-dose senna for bowel cleansing before colonoscopy: a randomized, investigator-blinded trial.

    PubMed

    Amato, Arnaldo; Radaelli, Franco; Paggi, Silvia; Terruzzi, Vittorio

    2010-03-01

    Patients' compliance with and tolerance of large-volume polyethylene glycol electrolyte solution (PEG-ES) have prompted continuous investigation with alternative forms of cleansing. High-dose senna is superior to PEG-ES for the quality of bowel cleansing, patient compliance, and tolerance, but its acceptance may be influenced by the incidence of abdominal pain. We hypothesized that a combination of half doses of PEG-ES and senna could minimize the incidence of abdominal pain without affecting the quality of bowel preparation. This randomized, investigator-blinded trial has been conducted on consecutive outpatients scheduled for elective colonoscopy at a single community-based hospital. Patients were randomly assigned to receive either 12 tablets of 12 mg senna and 2 l of PEG-ES (half-dose group, HDG) or 24 tablets of senna divided in two doses (senna group, SG) the day before colonoscopy. The main outcome measures were the quality of colon cleansing (Aronchick scoring scale) and the incidence of preparation-related abdominal pain. Secondary outcome measures were patients' compliance with the cleansing regimen, overall tolerability, prevalence of predefined side effects, and quality of right colon cleansing. A total of 296 patients were enrolled (HDG=151 and SG=145). Overall cleansing was excellent to good in 90.1 and 88.3% patients in HDG and SG, respectively (P=0.62). Preparation-related moderate-to-severe abdominal pain was reported by 6% patients in HDG and 15.2% in SG (P=0.009). No significant differences were observed for secondary outcomes. The regimen combining half doses of PEG-ES and senna provides high-quality bowel preparation and acceptable patient tolerance, with less abdominal pain compared with high-dose senna.

  14. Washing the guilt away: effects of personal versus vicarious cleansing on guilty feelings and prosocial behavior

    PubMed Central

    Xu, Hanyi; Bègue, Laurent; Bushman, Brad J.

    2014-01-01

    For centuries people have washed away their guilt by washing their hands. Do people need to wash their own hands, or is it enough to watch other people wash their hands? To induce guilt, we had participants write about a past wrong they had committed. Next, they washed their hands, watched a washing-hands video, or watched a typing-hands video. After the study was over, participants could help a Ph.D. student complete her dissertation by taking some questionnaires home and returning them within 3 weeks. Results showed that guilt and helping behavior were lowest among participants who washed their hands, followed by participants who watched a washing-hands video, followed by participants who watched a typing-hands video. Guilt mediated the effects of cleansing on helping. These findings suggest that washing one’s own hands, or even watching someone else wash their hands, can wash away one’s guilt and lead to less helpful behavior. PMID:24616686

  15. Nursing Care Hour Standards Study. Part 1. Section B. Patient Classification System Model Development

    DTIC Science & Technology

    1981-09-01

    Measurement/Adult El FI~ [El 1:11] II PIES Form 326e (OT) 1 Novembeti 1978 A-3 sfti= 237 Saline IrrigatioD (Gastric)W uli il 111 Enema: Cleansing Mi...U lIED Dilatation and -Curettage/Assisting Physician ii) El Do~ EI M.1 L or Evacuation Vaginal /Pelvic Examinrations/Assisting Physician ElU L. IE l2...ADMINISTRATION: Oral -QB E ED EE ElE Suppositories Rectal/ Vaginal 1E El El El I ElD Topical MI~II iE Sublingual III ol El El El DIAGNOSTIC TESTS: Bone

  16. Small bowel preparations for capsule endoscopy with mannitol and simethicone: a prospective, randomized, clinical trial.

    PubMed

    Chen, Hong-bin; Huang, Yue; Chen, Su-yu; Song, Hui-wen; Li, Xiao-lin; Dai, Dong-lin; Xie, Jia-tia; He, Song; Zhao, Yuan-yuan; Huang, Chun; Zhang, Sheng-jun; Yang, Lin-na

    2011-04-01

    There is no consensus concerning small bowel preparation before capsule endoscopy (CE). This study evaluated the effects of 4 regimens on small bowel cleansing and diagnostic yield. Patients were randomly divided into 4 groups. Group A consumed a clear liquid diet after lunch on the day before CE, followed by overnight fasting. Group B took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In group C, the same regimen was taken at 20:00 hours on the day before and at 05:00 hours on the day of CE. In group D, in addition to the group C regimen, 20 mL oral simethicone was taken 30 minutes before CE. Two hundred patients were prospectively enrolled, and 7 were excluded from the final analysis because of incomplete small bowel transit. No significant difference was noted among the 4 groups for small bowel transit time. Bowel preparation in group D was significantly better than for the other regimens for overall cleansing of the proximal small bowel, and showed improved overall cleansing of the distal small bowel when compared with 10-hours overnight fasting. Pathological lesions of the proximal and distal small bowel were, respectively, achieved in 82 and 74 patients, mostly distributed in group D. Small bowel preparation that involves split-dose oral mannitol plus single-dose simethicone for CE can improve mucosal visualization and subsequent diagnostic yield when compared with 10-hours overnight fasting.

  17. Oropharyngeal cleansing with 0.2% chlorhexidine for prevention of nosocomial pneumonia in critically ill patients: an open-label randomized trial with 0.01% potassium permanganate as control.

    PubMed

    Panchabhai, Tanmay S; Dangayach, Neha S; Krishnan, Anand; Kothari, Vatsal M; Karnad, Dilip R

    2009-05-01

    Oral cleansing with chlorhexidine decreases the incidence of nosocomial pneumonia in patients after cardiac surgery. However, evidence of its benefit in ICU patients is conflicting. Patients admitted to the ICU of an Indian tertiary care teaching hospital were randomized to twice-daily oropharyngeal cleansing with 0.2% chlorhexidine or 0.01% potassium permanganate (control) solution. Effects on the incidence of nosocomial pneumonia during ICU stay (primary outcome) and length of ICU stay and in-hospital mortality (secondary outcomes) were studied. Five hundred twelve patients were randomized to either the chlorhexidine group (n = 250) or the control group (n = 262). Of the 471 subjects who completed the protocol, nosocomial pneumonia developed in 16 of 224 subjects (7.1%) in the chlorhexidine group and 19 of 247 subjects (7.7%) in the control group (p = 0.82; relative risk, 0.93; 95% confidence interval, 0.49 to 1.76); intention-to-treat analysis of 21 patients in whom the cleansing protocol was not followed revealed similar results. There was no significant difference between the study and control groups in the median day of development of pneumonia (5.0 days: interquartile range [IQR], 3.0 to 7.7 vs 5.0 days: IQR, 3.0 to 6.0, respectively), median ICU stay (5.0 days: IQR, 3.0 to 8.0 vs 6.0 days: IQR, 3.0 to 8.0, respectively), and mortality (34.8% vs 28.3%, respectively). On subgroup analysis, there was no significant difference in the primary and secondary outcomes in patients on mechanical ventilation, tracheal intubation, and coma (Glasgow coma scale

  18. Comparison between different colon cleansing products for screening colonoscopy. A noninferiority trial in population-based screening programs in Italy.

    PubMed

    Zorzi, Manuel; Valiante, Flavio; Germanà, Bastianello; Baldassarre, Gianluca; Coria, Bartolomea; Rinaldi, Michela; Heras Salvat, Helena; Carta, Alessandra; Bortoluzzi, Francesco; Cervellin, Erica; Polo, Maria Luisa; Bulighin, Gianmarco; Azzurro, Maurizio; Di Piramo, Daniele; Turrin, Anna; Monica, Fabio

    2016-03-01

    The high volume and poor palatability of 4 L of polyethylene glycol (PEG)-based bowel cleansing preparation required before a colonoscopy represent a major obstacle for patients. The aim of this study was to compare two low volume PEG-based preparations with standard 4 L PEG in individuals with a positive fecal immunochemical test (FIT) within organized screening programs in Italy. A total of 3660 patients with a positive FIT result were randomized to receive, in a split-dose regimen, 4 L PEG or 2 L PEG plus ascorbate (PEG-A) or 2 L PEG with citrate and simethicone plus bisacodyl (PEG-CS). The noninferiority of the low volume preparations vs. 4 L PEG was tested through the difference in proportions of adequate cleansing. A total of 2802 patients were included in the study. Adequate bowel cleansing was achieved in 868 of 926 cases (93.7 %) in the 4 L PEG group, in 872 out of 911 cases in the PEG-A group (95.7 %, difference in proportions  + 1.9 %, 95 % confidence interval [CI]  - 0.1 to 3.9), and in 862 out of 921 cases in the PEG-CS group (93.6 %, difference in proportions  - 0.2 %, 95 %CI  - 2.4 to 2.0). Bowel cleansing was adequate in 95.5 % of cases when the preparation-to-colonoscopy interval was between 120 and 239 minutes, whereas it dropped to 83.3 % with longer intervals. Better cleansing was observed in patients with regular bowel movements (95.6 %) compared with those with diarrhea (92.4 %) or constipation (90.8 %). Low volume PEG-based preparations administered in a split-dose regimen guarantee noninferior bowel cleansing compared with 4 L PEG. Constipated patients require a personalized preparation. EudraCT 2012 - 003958 - 82. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Dual-energy index value of luminal air in fecal-tagging computed tomography colonography: findings and impact on electronic cleansing.

    PubMed

    Cai, Wenli; Zhang, Da; Lee, June-Goo; Shirai, Yu; Kim, Se Hyung; Yoshida, Hiroyuki

    2013-01-01

    The purpose of our study was to measure the dual-energy index (DEI) value of colonic luminal air in both phantom and clinical fecal-tagging dual-energy computed tomography (CT) colonography (DE-CTC) images and to demonstrate its impact on dual-energy electronic cleansing. For the phantom study, a custom-ordered colon phantom was scanned by a dual-energy CT scanner (SOMATON Definition Flash; Siemens Healthcare, Forchheim, Germany) at two photon energies: 80 and 140 kVp. Before imaging, the phantom was filled with a 300-mL mixture of simulated fecal materials tagged by a nonionic iodinated contrast agent at three contrast concentrations: 20, 40, and 60 mg/mL. Ten regions-of-interest (ROIs) were randomly placed in each of the colonic luminal air, abdominal fat, bony structure, and tagged material in each scan. For the clinical study, 22 DE-CTC (80 and 140 kVp) patient cases were collected, who underwent a low-fiber, low-residue diet bowel preparation and orally administered iodine-based fecal tagging. Twenty ROIs were randomly placed in each of the colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material in each scan. For each ROI, the mean CT values in both 80- and 140-kVp images were measured, and then its DEI was calculated. In the phantom study, the mean DEI values of luminal air were 0.270, 0.298, 0.386, and 0.402 for the four groups of tagging conditions: no tagged material and tagged with three groups of contrast concentrations at 20, 40, and 60 mg/mL. In the clinical study, the mean DEI values were 0.341, -0.012, -0.002, and 0.188 for colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material, respectively. In our study, we observed that the DEI values of colonic luminal air in DE-CTC images (>0.10) were substantially higher than the theoretical value of 0.0063. In addition, the observed DEI values of colonic luminal air were significantly higher than those of soft tissue. These findings have an important impact on electronic cleansing: it may provide an effective means of differentiating colonic soft-tissue structures from the air-tagging mixture caused by the partial volume effect and thus of minimizing the cleansing artifacts.

  20. Prolonged toxicity from Kambo cleansing ritual.

    PubMed

    Li, Kai; Horng, Howard; Lynch, Kara; Smollin, Craig G

    2018-04-02

    Kambo cleanse is a purification, cleansing ritual traditionally performed by South American shaman to confer luck and health to hunters. We report a patient who presented to the emergency department with prolonged symptoms of vomiting, flushing, facial swelling, altered mental status, and agitation requiring chemical restraints, 22 h after a Kambo cleanse. The patient was found with four small, circular, superficial burns to the ankle at the site where the resin was introduced. The cleanse consists of rubbing resin obtained from the secretions of the giant leaf frog (Phyllomedusa bicolor) into superficial wounds to produce intense gastrointestinal symptoms followed by a sensation of increased stamina and strength. The cleanse is now being increasingly performed in Europe and USA.

  1. Vaginal Cleansing Before Cesarean Delivery: A Systematic Review and Meta-analysis.

    PubMed

    Caissutti, Claudia; Saccone, Gabriele; Zullo, Fabrizio; Quist-Nelson, Johanna; Felder, Laura; Ciardulli, Andrea; Berghella, Vincenzo

    2017-09-01

    To assess the efficacy of vaginal cleansing before cesarean delivery in reducing postoperative endometritis. MEDLINE, Ovid, EMBASE, Scopus, Clinicaltrials.gov, and Cochrane Library were searched from their inception to January 2017. Selection criteria included all randomized controlled trials comparing vaginal cleansing (ie, intervention group) with a control group (ie, either placebo or no intervention) in women undergoing cesarean delivery. Any method of vaginal cleansing with any type of antiseptic solution was included. The primary outcome was the incidence of endometritis. Meta-analysis was performed using the random-effects model of DerSimonian and Laird to produce summary treatment effects in terms of relative risk (RR) with 95% CI. Sixteen trials (4,837 women) on vaginal cleansing immediately before cesarean delivery were identified as relevant and included in the review. In most of the included studies, 10% povidone-iodine was used as an intervention. The most common way to perform the vaginal cleansing was the use of a sponge stick for approximately 30 seconds. Women who received vaginal cleansing before cesarean delivery had a significantly lower incidence of endometritis (4.5% compared with 8.8%; RR 0.52, 95% CI 0.37-0.72; 15 studies, 4,726 participants) and of postoperative fever (9.4% compared with 14.9%; RR 0.65, 95% CI 0.50-0.86; 11 studies, 4,098 participants) compared with the control group. In the planned subgroup analyses, the reduction in the incidence of endometritis with vaginal cleansing was limited to women in labor before cesarean delivery (8.1% compared with 13.8%; RR 0.52, 95% CI 0.28-0.97; four studies, 440 participants) or those with ruptured membranes (4.3% compared with 20.1%; RR 0.23, 95% CI 0.10-0.52; three studies, 272 participants). Vaginal cleansing immediately before cesarean delivery in women in labor and in women with ruptured membranes reduces the risk of postoperative endometritis. Because it is generally inexpensive and a simple intervention, we recommend preoperative vaginal preparation before cesarean delivery in these women with sponge stick preparation of povidone-iodine 10% for at least 30 seconds. More data are needed to assess whether this intervention may be also useful for cesarean deliveries performed in women not in labor and for those without ruptured membranes. PROSPERO International prospective register of systematic reviews, https://www.crd.york.ac.uk/PROSPERO/, CRD42017054843.

  2. Baby Shampoo Versus Povidone-Iodine or Isopropyl Alcohol in Reducing Eyelid Skin Bacterial Load.

    PubMed

    Garcia, Giancarlo A; Nguyen, Christine V; Yonkers, Marc A; Tao, Jeremiah P

    Baby shampoo is used as an alternative surgical skin preparation, but the evidence supporting its use is scarce with no descriptions of efficacy in the periocular region. The authors compare the efficacy of baby shampoo, povidone-iodine (PI, Betadine) and isopropyl alcohol (IA) in reducing eyelid skin bacterial load. Prospective, randomized, comparative, and interventional trial. Bacterial load on adult, human eyelid skin was quantitated before and after cleansing with 1) dilute baby shampoo, 2) 10% PI, or 3) 70% IA. Paired skin swabs were collected from a 1 cm area of the upper eyelid of subjects before and after a standardized surgical scrub technique. Samples were cultured on 5% sheep blood agar for 24 hours. The number of colony forming units (CFU) was assessed and bacterial load per square centimeter of eyelid skin was quantified. Baseline and postcleansing samples were assessed from 42 eyelids of 42 subjects (n = 14 for each of baby shampoo, PI, and IA). Before cleansing, similar amounts of bacterial flora were grown from all specimens (median log CFU/cm = 2.04 before baby shampoo, 2.01 before PI, 2.11 before IA; p > 0.05). All 3 cleansing agents significantly reduced the bacterial load (p < 0.01 for each). There was no statistically significant difference in postcleansing bacterial load between the 3 cleansing agents (median log CFU/cm = 0.48 after baby shampoo, 0.39 after PI, 0.59 after IA; p > 0.05). Change from baseline in bacterial load was statistically similar for all 3 agents (median reduction in log CFU/cm = 1.28 with baby shampoo, 1.57 with PI, 1.40 with IA; p > 0.05). These corresponded to bacterial load reductions of 96.3%, 96.6%, and 98.4% for baby shampoo, PI, and IA, respectively. Baby shampoo achieved comparable diminution in eyelid skin bacterial load to PI or IA. These data suggest baby shampoo may be an effective preoperative cleansing agent.

  3. Oral purgative and simethicone before small bowel capsule endoscopy

    PubMed Central

    Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José

    2013-01-01

    AIM: To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. METHODS: Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. RESULTS: There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered to have poor small bowel cleansing (P = 0.417), with significant fluid or debris such that the examination was unreliable. The proportion of patients with a significant amount of bubbles was 50% in Group A, 27.8% in Group B and 15.8% in Group C (P = 0.065). This was significantly lower in Group C when compared to Group A (P = 0.026). The mean GET was 27.8 min for Group A, 27.2 min for Group B and 40.7 min for Group C (P = 0.381). The mean SBTT was 256.4 min for Group A, 256.1 min for Group B and 258.1 min for Group C (P = 0.998). Regarding to the rate of complete examinations, the capsule reached the cecum in 20 patients (100%) in Group A, 16 patients (88.9%) in Group B and 17 patients (89.5%) in Group C (P = 0.312). A definite diagnosis based on relevant small bowel endoscopic lesions was established in 60% of the patients in Group A (12 patients), 44.4% in Group B (8 patients) and 57.8% in Group C (11 patients) (P = 0.587). CONCLUSION: Preparation with 2 L of PEG before small bowel capsule endoscopy (SBCE) may improve small bowel cleansing and the quality of visualization. Simethicone may further reduce intraluminal bubbles. No significant differences were found regarding GET, SBTT and the proportion of complete exploration or diagnostic yield among the three different cleansing protocols. PMID:23424190

  4. Oral purgative and simethicone before small bowel capsule endoscopy.

    PubMed

    Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José

    2013-02-16

    To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered to have poor small bowel cleansing (P = 0.417), with significant fluid or debris such that the examination was unreliable. The proportion of patients with a significant amount of bubbles was 50% in Group A, 27.8% in Group B and 15.8% in Group C (P = 0.065). This was significantly lower in Group C when compared to Group A (P = 0.026). The mean GET was 27.8 min for Group A, 27.2 min for Group B and 40.7 min for Group C (P = 0.381). The mean SBTT was 256.4 min for Group A, 256.1 min for Group B and 258.1 min for Group C (P = 0.998). Regarding to the rate of complete examinations, the capsule reached the cecum in 20 patients (100%) in Group A, 16 patients (88.9%) in Group B and 17 patients (89.5%) in Group C (P = 0.312). A definite diagnosis based on relevant small bowel endoscopic lesions was established in 60% of the patients in Group A (12 patients), 44.4% in Group B (8 patients) and 57.8% in Group C (11 patients) (P = 0.587). Preparation with 2 L of PEG before small bowel capsule endoscopy (SBCE) may improve small bowel cleansing and the quality of visualization. Simethicone may further reduce intraluminal bubbles. No significant differences were found regarding GET, SBTT and the proportion of complete exploration or diagnostic yield among the three different cleansing protocols.

  5. Method for modeling post-mortem biometric 3D fingerprints

    NASA Astrophysics Data System (ADS)

    Rajeev, Srijith; Shreyas, Kamath K. M.; Agaian, Sos S.

    2016-05-01

    Despite the advancements of fingerprint recognition in 2-D and 3-D domain, authenticating deformed/post-mortem fingerprints continue to be an important challenge. Prior cleansing and reconditioning of the deceased finger is required before acquisition of the fingerprint. The victim's finger needs to be precisely and carefully operated by a medium to record the fingerprint impression. This process may damage the structure of the finger, which subsequently leads to higher false rejection rates. This paper proposes a non-invasive method to perform 3-D deformed/post-mortem finger modeling, which produces a 2-D rolled equivalent fingerprint for automated verification. The presented novel modeling method involves masking, filtering, and unrolling. Computer simulations were conducted on finger models with different depth variations obtained from Flashscan3D LLC. Results illustrate that the modeling scheme provides a viable 2-D fingerprint of deformed models for automated verification. The quality and adaptability of the obtained unrolled 2-D fingerprints were analyzed using NIST fingerprint software. Eventually, the presented method could be extended to other biometric traits such as palm, foot, tongue etc. for security and administrative applications.

  6. Vaginal preparation with antiseptic solution before cesarean section for preventing postoperative infections.

    PubMed

    Haas, David M; Morgan, Sarah; Contreras, Karenrose

    2014-09-09

    Cesarean delivery is one of the most common surgical procedures performed by obstetricians. Infectious morbidity after cesarean delivery can have a tremendous impact on the postpartum woman's return to normal function and her ability to care for her baby. Despite the widespread use of prophylactic antibiotics, postoperative infectious morbidity still complicates cesarean deliveries. To determine if cleansing the vagina with an antiseptic solution before a cesarean delivery decreases the risk of maternal infectious morbidities, including endometritis and wound complications. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (21 July 2014). We included randomized and quasi-randomized trials assessing the impact of vaginal cleansing immediately before cesarean delivery with any type of antiseptic solution versus a placebo solution/standard of care on post-cesarean infectious morbidity. We independently assessed eligibility and quality of the studies. Five trials randomizing 1946 women (1766 analyzed) evaluated the effects of vaginal cleansing (all with povidone-iodine) on post-cesarean infectious morbidity. The risk of bias was generally low, with the quality of most of the studies being high. Vaginal preparation immediately before cesarean delivery significantly reduced the incidence of post-cesarean endometritis from 7.2% in control groups to 3.6% in vaginal cleansing groups (average risk ratio (RR) 0.39, 95% confidence interval (CI) 0.16 to 0.97, five trials, 1766 women). The risk reduction was particularly strong for women with ruptured membranes (1.4% in the vaginal cleansing group versus 15.4% in the control group; RR 0.13, 95% CI 0.02 to 0.66, two trials, 148 women). No other outcomes realized statistically significant differences between the vaginal cleansing and control groups. No adverse effects were reported with the povidone-iodine vaginal cleansing.The quality of the evidence using GRADE was low for post-cesarean endometritis, moderate for postoperative fever, and low for wound infection. Vaginal preparation with povidone-iodine solution immediately before cesarean delivery reduces the risk of postoperative endometritis. This benefit is particularly realized for women undergoing cesarean delivery with ruptured membranes. As a simple, generally inexpensive intervention, providers should consider implementing preoperative vaginal cleansing with povidone-iodine before performing cesarean deliveries.

  7. Evidence-based recommendations for bowel cleansing before colonoscopy in children: a report from a national working group.

    PubMed

    Turner, D; Levine, A; Weiss, B; Hirsh, A; Shamir, R; Shaoul, R; Berkowitz, D; Bujanover, Y; Cohen, S; Eshach-Adiv, O; Jamal, Gera; Kori, M; Lerner, A; On, A; Rachman, L; Rosenbach, Y; Shamaly, H; Shteyer, E; Silbermintz, A; Yerushalmi, B

    2010-12-01

    There are no current recommendations for bowel cleansing before colonoscopy in children. The Israeli Society of Pediatric Gastroenterology and Nutrition (ISPGAN) established an iterative working group to formulate evidence-based guidelines for bowel cleansing in children prior to colonoscopy. Data were collected by systematic review of the literature and via a national-based survey of all endoscopy units in Israel. Based on the strength of evidence, the Committee reached consensus on six recommended protocols in children. Guidelines were finalized after an open audit of ISPGAN members. Data on 900 colonoscopies per year were accrued, which represents all annual pediatric colonoscopies performed in Israel. Based on the literature review, the national survey, and the open audit, several age-stratified pediatric cleansing protocols were proposed: two PEG-ELS protocols (polyethylene-glycol with electrolyte solution); Picolax-based protocol (sodium picosulphate with magnesium citrate); sodium phosphate protocol (only in children over the age of 12 years who are at low risk for renal damage); stimulant laxative-based protocol (e. g. bisacodyl); and a PEG 3350-based protocol. A population-based analysis estimated that the acute toxicity rate of oral sodium phosphate is at most 3/7320 colonoscopies (0.041 %). Recommendations on diet and enema use are provided in relation to each proposed protocol. There is no ideal bowel cleansing regimen and, thus, various protocols are in use. We propose several evidence-based protocols to optimize bowel cleansing in children prior to colonoscopy and minimize adverse events. © Georg Thieme Verlag KG Stuttgart · New York.

  8. High- versus low-volume polyethylene glycol plus laxative versus sennosides for colonoscopy preparation in children.

    PubMed

    Kierkus, Jaroslaw; Horvath, Andrea; Szychta, Monika; Woynarowski, Marek; Wegner, Agnieszka; Wiernicka, Anna; Dadalski, Maciej; Teisseyre, Mikolaj; Dziechciarz, Piotr

    2013-08-01

    Many protocols of bowel preparation are available for use in children; however, none of them is commonly accepted. The aim of the study was to evaluate the efficacy and acceptability of high-volume polyethylene glycol (PEG) versus low-volume PEG combined with bisacodyl (BPEG) versus sennosides for colonoscopy preparation in children. Participants ages 10 to 18 years were randomly assigned to receive either PEG 60 or PEG 30 mL kg⁻¹ day⁻¹ plus oral bisacodyl 10 to 15 mg/day or sennosides 2 mg kg⁻¹ day⁻¹ for 2 days. A blinded assessment of bowel cleansing was made by the endoscopist according to the Aronchick and Ottawa scales. Patient acceptability was evaluated with the visual-analog scale. Analysis was done on an available case analysis basis. Of 240 patients enrolled in the study 234 patients were available for analysis of the efficacy of colon cleansing. There were no significant differences found among the 3 groups for the proportions of participants with excellent/good (PEG: 35/79, BPEG: 26/79, sennosides 25/76) and poor/inadequate (PEG: 20/79, BPEG: 28/79, sennosides 28/76) bowel preparation evaluated with the Aronchick scale and for the mean Ottawa total score (PEG: 5.47 ± 3.63, BPEG: 6.22 ± 3.3, sennosides: 6.18 ± 3.53). Acceptability of bowel cleansing protocol was similar in all of the groups (P = 0.8). All 3 cleansing methods showed similar efficacy and tolerability; however, none of them was satisfactory.

  9. Simethicone improves bowel cleansing with low-volume polyethylene glycol: a multicenter randomized trial.

    PubMed

    Zhang, Shenghong; Zheng, Danping; Wang, Jinping; Wu, Jianwei; Lei, Pingguang; Luo, Qi; Wang, Liping; Zhang, Beiping; Wang, Hong; Cui, Yi; Chen, Minhu

    2018-04-01

     For bowel preparation, using a reduced volume of polyethylene glycol (PEG) solution without influencing its effectiveness would be preferable. While simethicone shows great potential as an adjunctive agent, data on its use are limited. We aimed to clarify whether simethicone added to low-volume PEG solution improved bowel cleansing. PATIENTS AND METHODS : Consecutive adult patients registered for colonoscopy were recruited from seven medical centers in South China between 15 April and 15 July 2015 and prospectively randomized into two groups: 2 L PEG (conventional group) and 2 L PEG plus simethicone (simethicone group). The primary endpoint was the effectiveness of bowel cleansing according to the Boston Bowel Preparation Scale (BBPS). Secondary endpoints included cecal intubation time, adenoma detection rate (ADR), patient safety and compliance, and adverse events. RESULTS : We included 290 and 289 patients in the conventional and simethicone groups, respectively, for analysis. The proportion with acceptable bowel cleansing (BBPS ≥ 6) was significantly higher in the simethicone group than in the conventional group (88.2 % vs. 76.6 %; P  < 0.001). The mean (SD) BBPS score was significantly lower in the conventional group (6.5 [1.8] vs. 7.3 [1.7]; P  < 0.001), as was the bubble score (2.5 [0.7] vs. 2.8 [0.5]; P  < 0.001). The average cecal intubation time was significantly shorter in the simethicone group (6.3 [3.1] vs. 7.5 [5.1] minutes; P  < 0.001). The ADR in the right colon was higher in the simethicone group than in the conventional group (16.6 % vs. 10.3 %; P  = 0.03). Safety and compliance, including the taste, smell, and dosage of PEG, were similar for both groups.  Simethicone added to low-volume PEG solution improves bowel-cleansing efficacy, with similar safety and compliance, shorter cecal intubation time, and higher ADR. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Colon Cleansing: Is It Helpful or Harmful?

    MedlinePlus

    ... https://naturalmedicines.therapeuticresearch.com. Accessed March 31, 2018. Detoxes and cleanses. National Center for Complementary and Integrative Health. https://nccih.nih.gov/health/detoxes-cleanses. Accessed March 29, 2018. Mishori R, et ...

  11. Effectiveness of Preanalytic Practices on Contamination and Diagnostic Accuracy of Urine Cultures: a Laboratory Medicine Best Practices Systematic Review and Meta-analysis

    PubMed Central

    Franek, Jacob; Leibach, Elizabeth K.; Weissfeld, Alice S.; Kraft, Colleen S.; Sautter, Robert L.; Baselski, Vickie; Rodahl, Debra; Peterson, Edward J.; Cornish, Nancy E.

    2015-01-01

    SUMMARY Background. Urinary tract infection (UTI) in the United States is the most common bacterial infection, and urine cultures often make up the largest portion of workload for a hospital-based microbiology laboratory. Appropriately managing the factors affecting the preanalytic phase of urine culture contributes significantly to the generation of meaningful culture results that ultimately affect patient diagnosis and management. Urine culture contamination can be reduced with proper techniques for urine collection, preservation, storage, and transport, the major factors affecting the preanalytic phase of urine culture. Objectives. The purposes of this review were to identify and evaluate preanalytic practices associated with urine specimens and to assess their impact on the accuracy of urine culture microbiology. Specific practices included collection methods for men, women, and children; preservation of urine samples in boric acid solutions; and the effect of refrigeration on stored urine. Practice efficacy and effectiveness were measured by two parameters: reduction of urine culture contamination and increased accuracy of patient diagnosis. The CDC Laboratory Medicine Best Practices (LMBP) initiative's systematic review method for assessment of quality improvement (QI) practices was employed. Results were then translated into evidence-based practice guidelines. Search strategy. A search of three electronic bibliographic databases (PubMed, SCOPUS, and CINAHL), as well as hand searching of bibliographies from relevant information sources, for English-language articles published between 1965 and 2014 was conducted. Selection criteria. The search contained the following medical subject headings and key text words: urinary tract infections, UTI, urine/analysis, urine/microbiology, urinalysis, specimen handling, preservation, biological, preservation, boric acid, boric acid/borate, refrigeration, storage, time factors, transportation, transport time, time delay, time factor, timing, urine specimen collection, catheters, indwelling, urinary reservoirs, continent, urinary catheterization, intermittent urethral catheterization, clean voided, midstream, Foley, suprapubic, bacteriological techniques, and microbiological techniques. Main results. Both boric acid and refrigeration adequately preserved urine specimens prior to their processing for up to 24 h. Urine held at room temperature for more than 4 h showed overgrowth of both clinically significant and contaminating microorganisms. The overall strength of this body of evidence, however, was rated as low. For urine specimens collected from women, there was no difference in rates of contamination for midstream urine specimens collected with or without cleansing. The overall strength of this evidence was rated as high. The levels of diagnostic accuracy of midstream urine collection with or without cleansing were similar, although the overall strength of this evidence was rated as low. For urine specimens collected from men, there was a reduction in contamination in favor of midstream clean-catch over first-void specimen collection. The strength of this evidence was rated as high. Only one study compared midstream collection with cleansing to midstream collection without cleansing. Results showed no difference in contamination between the two methods of collection. However, imprecision was due largely to the small event size. The diagnostic accuracy of midstream urine collection from men compared to straight catheterization or suprapubic aspiration was high. However, the overall strength of this body of evidence was rated as low. For urine specimens collected from children and infants, the evidence comparing contamination rates for midstream urine collection with cleansing, midstream collection without cleansing, sterile urine bag collection, and diaper collection pointed to larger reductions in the odds of contamination in favor of midstream collection with cleansing over the other methods of collection. This body of evidence was rated as high. The accuracy of diagnosis of urinary tract infection from midstream clean-catch urine specimens, sterile urine bag specimens, or diaper specimens compared to straight catheterization or suprapubic aspiration was varied. Authors' conclusions. No recommendation for or against is made for delayed processing of urine stored at room temperature, refrigerated, or preserved in boric acid. This does not preclude the use of refrigeration or chemical preservatives in clinical practice. It does indicate, however, that more systematic studies evaluating the utility of these measures are needed. If noninvasive collection is being considered for women, midstream collection with cleansing is recommended, but no recommendation for or against is made for midstream collection without cleansing. If noninvasive collection is being considered for men, midstream collection with cleansing is recommended and collection of first-void urine is not recommended. No recommendation for or against is made for collection of midstream urine without cleansing. If noninvasive collection is being considered for children, midstream collection with cleansing is recommended and collection in sterile urine bags, from diapers, or midstream without cleansing is not recommended. Whether midstream collection with cleansing can be routinely used in place of catheterization or suprapubic aspiration is unclear. The data suggest that midstream collection with cleansing is accurate for the diagnosis of urinary tract infections in infants and children and has higher average accuracy than sterile urine bag collection (data for diaper collection were lacking); however, the overall strength of evidence was low, as multivariate modeling could not be performed, and thus no recommendation for or against can be made. PMID:26598386

  12. High-dose senna compared with conventional PEG-ES lavage as bowel preparation for elective colonoscopy: a prospective, randomized, investigator-blinded trial.

    PubMed

    Radaelli, Franco; Meucci, Gianmichele; Imperiali, Gianni; Spinzi, Giancarlo; Strocchi, Enrico; Terruzzi, Vittorio; Minoli, Giorgio

    2005-12-01

    To compare the efficacy and patient acceptance of an oral high dose of senna to conventional polyethylene glycol-electrolyte lavage solution (PEG-ES) in adults undergoing elective colonoscopy. Consecutive outpatients referred for elective colonoscopy were prospectively randomly assigned to receive, the day before the procedure, either 24 tablets of 12 mg senna, divided into two doses at 1 p.m. and 9 p.m. (senna group, n=191), or standard 4-L PEG-ES (PEG-ES group, n=92). The overall quality of colon cleansing (primary outcome measure) and cleansing in the right colon were evaluated using the Aronchick scoring scale (1=excellent to 4=inadequate) by the investigator/endoscopist who was blinded to the treatment assignment. Patient acceptance and the safety of the preparation were assessed by a nurse, using a structured questionnaire covering compliance with the dosing, overall tolerance of the preparation (1=none or mild discomfort to 4=severely distressing), and adverse events. The quality of colon cleansing, overall tolerance of the preparation, and compliance were significantly better with senna; overall cleansing was excellent or good in 90.6% of patients in the senna group and in 79.7% in the PEG-ES group (p= 0.003). The percentage of procedures rescheduled because of insufficient colon cleansing was 7.3% in the PEG-ES group and 2.6% in the senna group (p=0.035). Multivariate logistic regression modeling showed the PEG-ES preparation as negative independent predictor of unsuccessful bowel cleansing. The incidence of adverse reactions was similar in the two groups; patients who received senna experienced significantly less nausea and vomiting, but more abdominal pain. An oral high dose of senna is a valid alternative to standard PEG-ES for outpatient colonoscopy preparation.

  13. Threats to Moral Identity: Testing the Effects of Incentives and Consequences of One’s Actions on Moral Cleansing

    PubMed Central

    Harkrider, Lauren N.; Tamborski, Michael A.; Wang, Xiaoqian; Brown, Ryan P.; Mumford, Michael D.; Connelly, Shane; Devenport, Lynn D.

    2015-01-01

    Individuals engage in moral cleansing, a compensatory process to reaffirm one’s moral identity, when one’s moral self-concept is threatened. However, too much moral cleansing can license individuals to engage in future unethical acts. This study examined the effects of incentives and consequences of one’s actions on cheating behavior and moral cleansing. Results found that incentives and consequences interacted such that unethical thoughts were especially threatening, resulting in more moral cleansing, when large incentives to cheat were present and cheating explicitly harmed others. Implications are discussed in terms of ethics training, using incentives as motivators, and the depersonalized norms of science. PMID:26085781

  14. Cosmetic Cleansing Oil Absorption by Soft Contact Lenses in Dry and Wet Conditions.

    PubMed

    Tsukiyama, Junko; Miyamoto, Yuko; Kodama, Aya; Fukuda, Masahiko; Shimomura, Yoshikazu

    2017-09-01

    Previous reports showed that cosmetic cleansing oil for removing makeup, which contains mineral oil and surfactant, can deform some silicone hydrogel contact lenses (SHCLs) when applied directly to the lenses, although plasma-coated SHCLs (lotrafilcon A and B) were not affected. In the present study, we investigated hydrogel lenses and SHCLs in both wet and dry conditions. Several brands of hydrogel and SHCLs were immersed in a cleansing oil solution containing Sudan Black B for 5 min under wet and dry conditions. The lenses under the wet condition were simply picked up from the saline, whereas those under the dry condition were blotted with paper wipes. After immersing, the excess solution remaining on the lenses was removed by finger rubbing with a multipurpose solution. The lenses were then examined using a stereomicroscope, and their mean brightness was measured and compared. The cosmetic cleansing oil was not absorbed by the hydrogel lenses under wet or dry conditions. However, four of seven brands of SHCLs absorbed the cosmetic cleansing oil under both conditions (dry and wet), whereas asmofilcon A absorbed it only under the dry condition. Lotrafilcon B and delefilcon A did not absorb cleansing oil even under the dry condition. Hydrogel lenses resist cosmetic cleansing oil. However, SHCLs have different degrees of resistance depending on the lens material. Some SHCLs absorbed cosmetic cleansing oil more under dry conditions than under wet conditions.

  15. A feasibility study on laxative-free bowel preparation for virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Liang, Zhengrong; Chen, Dongqing; Wax, Mark; Lakare, Sarang; Li, Lihong; Anderson, Joseph; Kaufman, Arie; Harrington, Donald

    2005-04-01

    Objective: To investigate the feasibility of laxative-free bowel preparation to relieve the patient stress in colon cleansing for virtual colonoscopy. Materials and Methods: Three different bowel-preparation protocols were investigated by 60 study cases from 35 healthy male volunteers. All the protocols utilize low-residue diet for two days and differ in diet for the third day - the day just prior to image acquisition in the fourth day morning. Protocol Diet-1 utilizes fluid or liquid diet in the third day, Diet-2 utilizes a food kit, and Diet-3 remains the low-residue diet. Oral contrast of barium sulfate (2.1%, 250 ml) was added respectively to the dinner in the second day and the three meals in the third day. Two doses of MD-Gastroview (60 ml) were ingested each in the evening of the third day and in the morning before image acquisition. Images were acquired by a single-slice detector spiral CT (computed tomography) scanner with 5 mm collimation, 1 mm reconstruction, 1.5-2.0:1.0 pitch, 100-150 mA, and 120 kVp after the colons were inflated by CO2. The contrasted colonic residue materials were electronically removed from the CT images by specialized computer-segmentation algorithms. Results: By assumptions that the healthy young volunteers have no polyp and the image resolution is approximately 4 mm, a successful electronic cleansing is defined as "no more than five false positives and no removal of a colon fold part greater than 4 mm" for each study case. The successful rate is 100% for protocol Diet-1, 77% for Diet-2 and 57% for Diet-3. Conclusion: A laxative-free bowel preparation is feasible for virtual colonoscopy.

  16. Cleansing lotion containing tamarind fruit pulp extract. II. Study of cumulative irritation effects in human.

    PubMed

    Maenthaisong, Ratree; Viyoch, Jarupa; Chaiyakunapruk, Nathorn; Warnnissorn, Prateep

    2007-09-01

    Cleansing lotion containing extract of tamarind fruit pulp was developed to provide skin a lighter effect. Skin irritation may occur due to keratolytic effect of alpha-hydroxyl acids (AHA) in the tamarind fruit pulp extract. To assess the cumulative irritation effect of cleansing lotion containing tamarind fruit extract with 2% (w/w) tartaric acid on human skin compared with placebo product and de-ionized water. The study design was a single-blinded, randomized side of arm, and controlled study. Three samples, including test product, placebo product, and de-ionized water, were repeatedly applied on the inner forearm of 15 healthy females (aged 28.3 +/- 3.1 years) for 30 min daily for 5 days under semi-occlusive patch. Skin irritation was measured by using visual scoring and instruments such as Tewameter and Mexameter. All measurements were done before application of samples every day from day 1 until day 5. Final measurements were done after the last application for 3 days (day 8). The results obtained from the visual scoring scale indicated no irritation signs and symptoms of test product. Mean differences of transepidermal water loss and erythema values between test product and de-ionized water and between test and placebo products were not statistically significant (P > 0.05). These findings indicate a preliminary safety evidence of our developed cleansing lotion containing the natural AHAs and can be used as cumulative evidence for supporting the future home use study of this product in human.

  17. A new low-volume isosmotic polyethylene glycol solution plus bisacodyl versus split-dose 4 L polyethylene glycol for bowel cleansing prior to colonoscopy: a randomised controlled trial.

    PubMed

    Cesaro, Paola; Hassan, Cesare; Spada, Cristiano; Petruzziello, Lucio; Vitale, Giovanna; Costamagna, Guido

    2013-01-01

    4-L polyethylene glycol preparations are effective for colon cleansing before colonoscopy. However, large volume and unpleasant taste reduce tolerability and acceptability limiting patient compliance. A new isosmotic low-volume polyethylene glycol preparation with citrates and simethicone plus bisacodyl has been developed to improve patient compliance and tolerability. To compare the efficacy of 2 different regimens of preparation vs a split-dose of polyethylene glycol solution. In this randomised, blinded, comparative study, 153 patients were allocated to 3 arms. Arm 1 (n=52) received bisacodyl and 2-L polyethylene glycol with citrates and simethicone the day before the procedure. Arm 2 (n=50) received bisacodyl the day before and 2-L polyethylene glycol with citrates and simethicone on the day of colonoscopy. Control group (n=51) received a split-dose of 4-L polyethylene glycol. Cleansing was evaluated according to Ottawa scale. The mean Ottawa score was not different in the 3 groups. Excellent cleansing was observed more frequently in arm 2 (70%) than in controls (49%) (p<0.05). No serious adverse events were observed in the 3 regimens. The willingness to repeat the same bowel preparation was superior in arms 1 and 2 than in controls (p<0.001). New low-volume preparations seem to be as effective as the split 4-L polyethylene glycol regimen, showing a better tolerability and acceptability. Copyright © 2012. Published by Elsevier Ltd.

  18. Preparation before colonoscopy: a randomized controlled trial comparing different regimes.

    PubMed

    Jansen, Sita V; Goedhard, Jelle G; Winkens, Bjorn; van Deursen, Cees Th B M

    2011-10-01

    A good bowel preparation is essential for optimal visualization of the large intestine. Several preparations with a difference in composition and volume are available. We compared five methods for bowel cleansing quality and patients' acceptability. Adult ambulatory outpatients scheduled for elective colonoscopy were randomized to receive 4-l polyethylene glycol (PEG) solution (Klean-prep), 2-l PEG solution+ascorbic acid (Moviprep), or a sodium phosphate (NaP) solution, Phosphoral. Patients with the PEG solutions were also randomized to receive simethicone (Aeropax), to investigate whether this improves the bowel cleansing efficacy. Before colonoscopy patients completed a questionnaire about the acceptability and tolerability of the preparation. Endoscopists blinded to the type of preparation gave a bowel cleansing score. Data were available for 461 patients. 2-l PEG+ascorbic acid was noninferior to 4-l PEG in bowel cleansing quality of rectosigmoid and colon. NaP was noninferior to 4-l PEG in bowel cleansing quality of rectosigmoid but inferior for the whole colon. Compliance was significantly less in the group with 4-l PEG compared with the 2-l PEG and NaP group. No difference was found for abdominal cramps. Taste was significantly better in the 2-l PEG group. Simethicone did not improve the bowel cleansing quality. 2-l PEG+ascorbic acid was noninferior to the 4-l PEG solution in bowel cleansing quality and was better in taste and compliance. NaP was inferior to 4-l PEG in bowel cleansing quality. Addition of simethicone gave no improvement.

  19. Effect of bowel cleansing on colonic transit in constipation due to slow transit or evacuation disorder.

    PubMed

    Sloots, C E J; Felt-Bersma, R J F

    2002-02-01

    Colon transit time measurement with radio-opaque markers is a method of studying the passage of luminal contents throughout the colon. Overall colonic transit time (CTT), as well as segmental transit times [right (RTT), left (LTT) and rectosigmoid (RSTT)], can be calculated. We hypothesize that CTT is influenced by faecal impaction when the rectum is emptied infrequently. The aim of this study is to investigate the effect of bowel cleansing on colonic transit time in patients with chronic constipation. In 25 women (age 41 years; range 20-65 years) with constipation according to Thompson criteria, CTT measurement was performed in an unprepared situation and repeated after cleansing with 4 L of Klean-Prepreg. Ten healthy female volunteers (age 41 years; range 27-57 years) were used as controls. In constipated patients, CTT decreased from a median 70 h (range 10-130 h) to 48 h (5-94 h) in the cleansed state (P < 0.001). A shortening of transit time was found in all three segments. In 10 patients with slow transit (ST) (CTT > 86 h), CTT decreased from 110 h (range 94-130) to 86 (38-94) (P < 0.001). Five of the 10 patients with ST before bowel cleansing had a CTT below 86 h after cleansing. In female controls, uncleansed CTT and RSTT shortened from 39 h (23 to 62) and 17 h (8-29) to 29 h (17-48) and 10 h (0-20) after bowel cleansing (P=0.058 and P=0.046). Colonic intraluminal contents have a substantial effect on colonic transit. In female controls, bowel cleansing shortened rectosigmoid transit. Women with constipation had faster transit in the cleansed state, however, the distribution of markers was not altered. Despite the effect of bowel cleansing on CTT, it seems unnecessary to prepare the bowel in clinical practice because the differentiation of patients between slow transit constipation and outlet obstruction is not changed. However, because in an infrequent defecation pattern, the influence of faecal impaction is considerable, CTT should be applied with care for critical clinical decisions in the treatment of constipation.

  20. Change in the nose areas in children with mouth breathing after nasal cleansing and massage.

    PubMed

    Melo, Ana Carolina Cardoso de; Gomes, Adriana de Oliveira Camargo; Cunha, Daniele Andrade da; Lima, Sandro Júnior Henrique; Lima, Wigna Rayssa Pereira; Cunha, Renata Andrade da; Silva, Hilton Justino da

    2016-01-01

    To analyze the changes occurred in the nasal cavity geometry, before and after nasal cleansing, through nasal aeration and acoustic rhinometry in children with oral breathing. Twenty children aged four to 12 years were included in the study. The gathering of participants was conducted at the Multifunctional Laboratory of the Speech Pathology Department of the Federal University of Pernambuco - UFPE. The following procedures were conducted: Identification Index of Signs and Symptoms of Oral Breathing; marking of nasal expiratory airflow using the graded mirror of Altmann, and examination of the Nasal Geometry by Acoustic Rhinometry. The same procedures were performed after nasal massage and cleansing with saline solution. Significant change was observed in the areas with respect to the nasal airflow on both sides after nasal cleansing and massage. As for nasal geometry, measured by acoustic rhinometry, comparison between the nostrils showed that the effect of cleansing and massage was discrete. Nasal aeration measures showed sensitivity to the cleansing and massage technique and measures of nasal geometry confirmed its effect on respiratory physiology.

  1. Standardized system for quantifying residual dirt on medical appliances cleansed in hospital washers--disinfectors: dirt detection by different methods.

    PubMed

    Sigler, K; Gásková, D; Chládková, K; Knebl, R; Wimmer, T; Vacata, V; Gebel, J

    2003-01-01

    An easy-to construct, easy-to-operate standardized system was developed for determining the residual biological contamination of surgical instruments, endoscopes and other medical appliances subjected to hospital cleansing and/or disinfection. It consists of standard-sized pieces of glass, metal or endoscope plastic--dirt carriers--either bare or enclosed in truncated Eppendorf caps to simulate hard-to-access conditions. The surface of the carriers is covered with model dirt simulating biological contamination and the carriers are then affixed to sturdy metal holders. Conventional model dirt were found to peel or flake off the carrier surface, lowering the precision of residual soil determination. A newly developed model dirt consisting of liver mash, lactose and sunflower oil and exhibiting low tendency to peel off surfaces was therefore used. The whole setup was subjected to chemical or enzymic cleansing programs at elevated temperature in hospital washer-disinfectors of two types, and the residual dirt after cleansing was determined by three methods. The method using toxicant-doped dirt that quenches the luminescence of an indicator bacterium Photobacterium phosphoreum gave satisfactory data under laboratory conditions but with hospital-washed samples it exhibited excessive fluctuations caused by bacterium--dirt interactions and by physical influences. Both other methods gave better results but displayed some process sensitivity. The luciferin-luciferase-based ATP bioluminescence assay sometimes gave low or even negative dirt level values and showed a low effect of reduced dirt accessibility on cleansing of metal carriers. The Bradford protein assay showed about equal cleansing efficiency for both easily and poorly accessible carriers after enzymic cleansing. Our system can be used for determining low levels of residual contamination of medical appliances after cleansing/disinfection and assessing the efficiency of commercial washer-disinfectors; its efficiency can be further increased by using a cleansing process-insensitive method for soil detection and quantification.

  2. Catheter port cleansing techniques and the entry of povidone-iodine into the epidural space.

    PubMed

    Paice, J A; DuPen, A; Schwertz, D

    1999-04-01

    To determine whether three epidural catheter port cleansing techniques used to apply a povidone-iodine solution differed with respect to the introduction of this solution through the epidural catheter. Experimental. Laboratory. Five DuPen (Davol, Cranston, RI) epidural catheters. Five DuPen epidural catheters each were cleansed twice with (a) a commercially available 10% povidone-iodine swabstick, (b) a commercially available pledget impregnated with 10% povidone-iodine, and (c) a gauze pad saturated with 10% povidone-iodine. The order of cleansing was randomized. Each solution was used to clean the port for 30 seconds, and the port was allowed to dry for 30 seconds, similar to the technique used in the clinical setting. After cleaning the catheter port, water was injected through the catheter, and the solution from the tip of the catheter was analyzed using absorbance spectrophotometry. Cleansing techniques, presence of povidone-iodine in catheter. A statistically significant difference existed between the three cleansing techniques, with the pledget yielding the lowest values of povidone-iodine contamination of the epidural catheter (Freidman test, p = 0.02). Use of pledgets allowed the least amount of povidone-iodine to enter the epidural catheter as compared with the swabsticks or gauze pads. Commercially available pledgets used to cleanse catheter injection ports may limit the introduction of 10% povidone-iodine into the epidural or intrathecal space.

  3. Systematic review and meta-analysis of colon cleansing preparations in patients with inflammatory bowel disease

    PubMed Central

    Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N

    2017-01-01

    AIM To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. METHODS Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. RESULTS Out of 439 citations, 4 trials fulfilled our inclusion criteria (n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). CONCLUSION In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population. PMID:28932092

  4. Systematic review and meta-analysis of colon cleansing preparations in patients with inflammatory bowel disease.

    PubMed

    Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N

    2017-08-28

    To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. Out of 439 citations, 4 trials fulfilled our inclusion criteria ( n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population.

  5. 21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... represented only as soap. (b) Products intended for cleansing the human body and which are not “soap” as set... for use in cleansing the body. 701.20 Section 701.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS COSMETIC LABELING Labeling of Specific...

  6. 21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... represented only as soap. (b) Products intended for cleansing the human body and which are not “soap” as set... use in cleansing the body. 701.20 Section 701.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS COSMETIC LABELING Labeling of Specific...

  7. Spacecraft utensil/hand cleansing fixture

    NASA Technical Reports Server (NTRS)

    Jonkoniec, T. G.

    1978-01-01

    A fixture which provides a means for a crewman to perform, in zero gravity, laboratory utensil/tool cleansing and personal hygiene functions such as handwashing, shaving, body wash, and teeth brushing is described. A prototype unit developed incorporating design improvements resulting from breadboard tests in a one gravity and zero gravity environment demonstrated the capability of performing the different cleansing functions.

  8. Efficacy of prokinetic agents in improving bowel preparation for colonoscopy.

    PubMed

    Mishima, Yuko; Amano, Yuji; Okita, Koichi; Takahashi, Yoshiko; Moriyama, Nobuyuki; Ishimura, Norihisa; Furuta, Kenji; Ishihara, Shunji; Adachi, Kyoichi; Kinoshita, Yoshikazu

    2008-01-01

    Colonoscopy plays an important role in the diagnosis and treatment of gastrointestinal illness in both Western countries and Japan. However, preparative bowel cleansing for colonoscopy is frequently troublesome for elderly and/or constipated patients, since they must drink larger volumes of lavage solution for adequate cleansing. We investigated the use of prokinetic agents for improving the efficacy and tolerability of bowel cleansing prior to colonoscopy. 613 patients were divided into two groups according to oral lavage solution used (polyethylene glycol or magnesium citrate), and were further randomized to receive either vehicle (100 ml water) alone, vehicle with 5 mg mosapride citrate, or vehicle with 50 mg itopride hydrochloride 30 min before administration of lavage solution. Experimental parameters included bowel cleansing quality, times to first defecation and completion of bowel cleansing, and incidence of uncomfortable abdominal symptoms during colonoscopy preparation. Administration of mosapride citrate or itopride hydrochloride prior to oral lavage solution did not significantly improve bowel cleansing quality. However, statistically significantly fewer uncomfortable abdominal symptoms were found in patients who received mosapride citrate or itopride hydrochloride versus vehicle alone. Prokinetic agents effectively decreased the incidence of uncomfortable abdominal symptoms experienced during colonoscopy preparation. Copyright 2008 S. Karger AG, Basel.

  9. Impact of the Quality of Bowel Cleansing on the Efficacy of Colonic Cancer Screening: A Prospective, Randomized, Blinded Study

    PubMed Central

    2015-01-01

    Objectives Efficacy of two low volume bowel cleansing preparations, polyethylene glycol plus ascorbate (PEG+Asc) and sodium picosulfate/magnesium citrate (NaPic/MgCit), were compared for polyp and adenoma detection rate (PDR and ADR) and overall cleansing ability. Primary endpoint was PDR (the number of patients with ≥1 polypoid or flat lesion recorded by the colonoscopist). Methods Diagnostic, surveillance or screening colonoscopy patients were enrolled into this investigator-blinded, multi-center Phase IV study and randomized 1:1 to receive PEG+Asc (administered the evening before and the morning of colonoscopy, per label) or NaPic/MgCit (administered in the morning and afternoon the day before colonoscopy, per label). The blinded colonoscopist documented any lesion and assessed cleansing quality (Harefield Cleansing Scale). Results Of 394 patients who completed the study, 393 (PEG+Asc, N=200; NaPic/MgCit, N=193) had a colonoscopy. Overall PDR for PEG+Asc versus NaPic/MgCit was 51.5% versus 44.0%, p=0.139. PDR and ADR on the right side of the bowel were significantly higher with PEG+Asc versus NaPic/MgCit (PDR: 56[28.0%] versus 32[16.6%], p=0.007; ADR: 42[21.0%] versus 23[11.9%], p=0.015), as was detection of flat lesions (43[21.5%] versus 25[13.0%], p=0.025). Cleansing quality was better with PEG+Asc than NaPic/MgCit (98.5% versus 57.5% considered successful cleansing). Overall, there were 132 treatment-emergent adverse events (93 versus 39 for PEG+Asc and NaPic/MgCit, respectively). These were mainly mild abdominal symptoms, all of which were reported for higher proportions of patients in the PEG+Asc than NaPic/MgCit group. Twice as many patients in the NaPic/MgCit versus the PEG+Asc group reported tolerance of cleansing solution as ‘very good’. Conclusions Compared with NaPic/MgCit, PEG+Asc may be more efficacious for overall cleansing ability, and subsequent detection of right-sided and flat lesions. This is likely attributable to the different administration schedules of the two bowel cleansing preparations, which may positively impact the detection and prevention of colorectal cancer, thereby improving mortality rates. Trial Registration ClinicalTrials.gov NCT01689792. PMID:25950434

  10. Changes in anthropometric measurements, body composition, blood pressure, lipid profile, and testosterone in patients participating in a low-energy dietary intervention

    PubMed Central

    Balliett, Mary; Burke, Jeanmarie R.

    2013-01-01

    Objective The purpose of this study was to describe changes in anthropometric measurements, body composition, blood pressure, lipid profile, and testosterone following a low–energy-density dietary intervention plus regimented supplementation program. Methods The study design was a pre-post intervention design without a control group. Normal participants were recruited from the faculty, staff, students, and community members from a chiropractic college to participate in a 21-day weight loss program. All participants (n = 49; 36 women, 13 men; 31 ± 10.3 years of age) received freshly prepared mostly vegan meals (breakfast, lunch, and dinner) that included 1200 to 1400 daily calories (5020.8 to 5857.6 J) for the women and 1600 to 1800 (6694.4 to 7531.2 J) daily calories for the men. Nutritional supplements containing enzymes that were intended to facilitate digestion, reduce cholesterol levels, increase metabolic rate, and mediate inflammatory processes were consumed 30 minutes before each meal. The regimented supplementation program included once-daily supplementation with a green drink that contained alfalfa, wheatgrass, apple cider vinegar, and fulvic acid throughout the study period. A cleanse supplementation containing magnesium, chia, flaxseed, lemon, camu camu, cat's claw, bentonite clay, tumeric, pau d'arco, chanca piedra, stevia, zeolite clay, slippery elm, garlic, ginger, peppermint, aloe, citrus bioflavonoids, and fulvic acid was added before each meal during week 2. During week 3, the cleanse supplementation was replaced with probiotic and prebiotic supplementation. Results Multiple paired t tests detected clinically meaningful reductions in weight (− 8.7 ± 5.54 lb) (− 3.9 ± 2.5 kg), total cholesterol (− 30.0 ± 29.77 mg/dL), and low-density lipoprotein cholesterol (− 21.0 ± 25.20 mg/dL) (P < .05). There was a pre-post intervention increase in testosterone for men (111.0 ± 121.13 ng/dL, P < .05). Conclusions Weight loss and improvements in total cholesterol and low-density lipoprotein cholesterol levels occurred after a low–energy-density dietary intervention plus regimented supplementation program. PMID:23997718

  11. Changes in anthropometric measurements, body composition, blood pressure, lipid profile, and testosterone in patients participating in a low-energy dietary intervention.

    PubMed

    Balliett, Mary; Burke, Jeanmarie R

    2013-03-01

    The purpose of this study was to describe changes in anthropometric measurements, body composition, blood pressure, lipid profile, and testosterone following a low-energy-density dietary intervention plus regimented supplementation program. The study design was a pre-post intervention design without a control group. Normal participants were recruited from the faculty, staff, students, and community members from a chiropractic college to participate in a 21-day weight loss program. All participants (n = 49; 36 women, 13 men; 31 ± 10.3 years of age) received freshly prepared mostly vegan meals (breakfast, lunch, and dinner) that included 1200 to 1400 daily calories (5020.8 to 5857.6 J) for the women and 1600 to 1800 (6694.4 to 7531.2 J) daily calories for the men. Nutritional supplements containing enzymes that were intended to facilitate digestion, reduce cholesterol levels, increase metabolic rate, and mediate inflammatory processes were consumed 30 minutes before each meal. The regimented supplementation program included once-daily supplementation with a green drink that contained alfalfa, wheatgrass, apple cider vinegar, and fulvic acid throughout the study period. A cleanse supplementation containing magnesium, chia, flaxseed, lemon, camu camu, cat's claw, bentonite clay, tumeric, pau d'arco, chanca piedra, stevia, zeolite clay, slippery elm, garlic, ginger, peppermint, aloe, citrus bioflavonoids, and fulvic acid was added before each meal during week 2. During week 3, the cleanse supplementation was replaced with probiotic and prebiotic supplementation. Multiple paired t tests detected clinically meaningful reductions in weight (- 8.7 ± 5.54 lb) (- 3.9 ± 2.5 kg), total cholesterol (- 30.0 ± 29.77 mg/dL), and low-density lipoprotein cholesterol (- 21.0 ± 25.20 mg/dL) (P < .05). There was a pre-post intervention increase in testosterone for men (111.0 ± 121.13 ng/dL, P < .05). Weight loss and improvements in total cholesterol and low-density lipoprotein cholesterol levels occurred after a low-energy-density dietary intervention plus regimented supplementation program.

  12. A System Approach to Navy Medical Education and Training. Appendix 35. Competency Curriculum for Urology Assistant.

    DTIC Science & Technology

    1974-08-31

    urinary diversion b. Remove temporary/j ermanent collection appliance c. Perform basic sto-A care d. Cleanse /examine cc’Alection device prior to...of micturition d. Determine the type/degree/duration of urethral, vaginal , wound, other urinary outlet discharges e. Determine location/site and...related o. Determine if problem is vaginal /gynacologic p. Determine if problem is scrotal related PERFORMANCE OBJECTIVE (Stimulus) When assigned to

  13. 40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...

  14. 40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...

  15. 40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...

  16. 40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...

  17. 40 CFR 799.9530 - TSCA in vitro mammalian cell gene mutation test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) The test should be designed to have a predetermined sensitivity and power. The number of cells... cleansed of pre-existing mutant cells. (D) Metabolic activation. Cells shall be exposed to the test...=/− test, colony sizing should be performed on at least one of the test cultures (the highest positive...

  18. EVALUATION OF OCULAR PROSTHESIS BIOFILM AND ANOPHTHALMIC CAVITY CONTAMINATION AFTER USE OF THREE CLEANSING SOLUTIONS

    PubMed Central

    Paranhos, Regina Márcia Zuccolotto Felippe; Batalhão, Carlos Henrique; Semprini, Marisa; Regalo, Simone Cecílio Hallak; Ito, Izabel Yoko; de Mattos, Maria da Glória Chiarello

    2007-01-01

    In addition to an initial socket discomfort, ocular prosthesis (OP) installation may allow the adherence of fungi and/or bacteria due to the superficial characteristics of the prosthesis’ material, use of inadequate cleansing solutions and methods, or because the void located between the internal portion of the prosthesis and the anophthalmic cavity (AC) mucosa. Objective: The aim of this study was to evaluate OP biofilm formation and the level of contamination of the internal portion of the OP and the AC in 24 patients. Material and Methods: Material was collected from the AC at the beginning of the study and 15 days after cleansing of the OP with 3 cleansing solutions: a neutral liquid soap, a multiuse solution for contact lens (Complete) and 0.12% chlorhexidine (Periogard). The collected materials were sowed in Petri dishes containing selective media for aerobic and facultative microorganisms, specifically staphylococci (Hipersalt agar with egg yolk), aerobic microorganisms (Brain Heart Infusion Blood Agar), streptococci (Mitis salivarius Agar), gram-negative bacilli (MacConkey Agar) and yeasts (Chromagar CandidaTM), incubated at 35°C or 37°C and the number of colony forming units were counted. Data were analyzed statistically by ANOVA, Friedman’s test and Spearman’s correlation. Results: Aerobic microorganisms, gram-negative bacilli and S. aureus were found in the OP biofilm and in the AC. There was statistically significant difference (p<0.05) between the number of microorganisms before and after the use of the cleansing solutions. Conclusion: There was positive correlation with respect to the microorganisms present in the OP biofilm and AC for the 4 proposed treatments, indicating that the decrease of OP contamination leads to AC contamination as well. PMID:19089097

  19. Cytomegalovirus survival and transferability and the effectiveness of common hand-washing agents against cytomegalovirus on live human hands.

    PubMed

    Stowell, Jennifer D; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L; Dollard, Sheila C; Bialek, Stephanie R; Cannon, Michael J; Schmid, D Scott

    2014-01-01

    Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 10(5) infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands.

  20. Cytomegalovirus Survival and Transferability and the Effectiveness of Common Hand-Washing Agents against Cytomegalovirus on Live Human Hands

    PubMed Central

    Stowell, Jennifer D.; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L.; Dollard, Sheila C.; Bialek, Stephanie R.; Cannon, Michael J.

    2014-01-01

    Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 105 infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands. PMID:24185855

  1. The Search for Legitimacy: Interventions Under the Responsibility to Protect

    DTIC Science & Technology

    2012-03-22

    the international community bears a responsibility to take action to protect civilians from mass murder, ethnic cleansing , or genocide irrespective...or large scale ‘ethnic cleansing ’ actual or apprehended, whether carried out by killing, forced expulsion, acts of terror or rape.24 The ICISS...temptation to identify as a ground for military intervention human rights violations falling short of outright killing or ethnic cleansing ”26 and did

  2. Essentials of Hair Care often Neglected: Hair Cleansing

    PubMed Central

    Draelos, Zoe D

    2010-01-01

    Why does the selection of hair cleansing products and conditioners seem complex? Why are there clear, opalescent, green, blue, glittery, cheap, expensive, thick, thin, fragrant, and unscented varieties of shampoos and conditioners? Why the whole cleansing process cannot be simplified by using the same bar soap used on the body for the hair? Does the shampoo selected really make a difference? What can a conditioner accomplish? PMID:21188020

  3. The long-term use of soap does not affect the pH-maintenance mechanism of human skin.

    PubMed

    Takagi, Y; Kaneda, K; Miyaki, M; Matsuo, K; Kawada, H; Hosokawa, H

    2015-05-01

    The pH at the surface of healthy human skin is around 5. Cleansing the skin with soap increases the pH of the skin, which then returns to a more acidic pH within a few hours. However, the effects of skin cleansing with soap over a long time on the pH regulatory system is still unclear. We compared the pH of the skin between users of a soap-based cleanser and of a mild-acidic cleanser prior to and following the cleansing. This study had two groups of subjects, one group who had used a soap-based cleanser for more than 5 years and the other group who had used a mild-acidic cleanser for more than 5 years. The pH on the inner forearm of each subject was measured prior to and for 6 h after cleansing with a soap bar. There were no differences between the pH of the skin these two groups prior to cleansing, immediately after cleansing or in the pH recovery rate for 6 h. These results suggest that long-term continuous use of a soap-based cleanser does not affect the pH-maintaining mechanism of human skin. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. [Colonic lavage prior to colonoscopy: comparable outcomes of two polyethylene-glycol preparations and a sodium-phosphate solution].

    PubMed

    Felt-Bersma, R J; Kooyman, G; Kuipers, E J

    2004-01-24

    Comparison of three cleansing solutions for bowel preparation prior to colonoscopy. Prospective, randomized. 140 outpatients referred for colonoscopy were randomized into three groups for cleansing with 4 litres PEG 4000, 4 litres PEG 3350 or with 90 ml sodium phosphate with an additional 2.5 litres of fluid. Between cleansing and colonoscopy, patients filled in a questionnaire concerning taste, abdominal cramps and tolerance to the procedure. Blinded to the type of cleansing the endoscopist scored the effects on the colon and rectosigmoid, and made the endoscopic diagnosis. All data were available for 127 of the 140 patients (50 men, 77 women), mean age 51 years (range 18-96). Comparison between the three groups showed no statistically significant difference in the opinion of the patients concerning taste, abdominal cramps and tolerance of lavage. The endoscopist's scoring of total colon cleansing showed a small reduction in colon cleanliness when using sodium phosphate compared to PEG 3350 (p = 0.03). No differences were found between the two PEG solutions. Combining both PEG solutions and comparing them with the sodium-phosphate solution showed fewer abdominal cramps (p = 0.07) with sodium phosphate and a cleaner colon with PEG (p = 0.07). Women complained slightly more of abdominal cramps and were slightly less tolerant of the procedure than men. Previous colonic surgery did not influence the results. Patients with diverticula were older, but no other effect of cleansing was found. The three preparations are comparable in their cleansing effect and tolerance by the patient.

  5. Systematic review and meta-analysis: Sodium picosulphate with magnesium citrate as bowel preparation for colonoscopy

    PubMed Central

    Munsterman, Isabelle D; Eskes, Anne M; Maaskant, Jolanda M; van der Hulst, René

    2016-01-01

    Background An effective and tolerable bowel preparation is important to secure quality of colonoscopies. It remains unclear if sodium picosulphate with magnesium citrate (SPMC), which is considered a tolerable bowel preparation agent, is also an effective alternative for polyethylene glycol (PEG) and sodium phosphate (NaP). Aim The aim of this article is to compare effectiveness of SPMC to PEG and NaP through assessment of quality of bowel cleansing measured by validated tools. Methods We searched electronic databases up to January 2015. Only randomised controlled trials (RCTs) were included. Two authors independently performed selection of studies, risk of bias assessment and data extraction. Results Thirteen RCTs were included, with overall good quality, but large heterogeneity. SPMC had slightly better quality of bowel cleansing than PEG (pooled RR 1.06; 95% CI 1.02 to 1.11). In most trials SPMC was significantly better tolerated than PEG. There were no significant differences in effectiveness or tolerability between SPMC and NaP. Side effects were similar between agents, except for dizziness (pooled RR 1.71; 95% CI 1.32 to 2.21 in favour of PEG vs. SPMC) and vomiting (pooled RR 0.35; 95% CI 0.13 to 0.95 in favour of single-dose SPMC vs. split-dose). Conclusions SPMC is equally effective to NaP and little superior to PEG in terms of bowel cleansing. SPMC preparations were better tolerated than PEG preparations. SPMC may be considered as standard bowel preparation for colonoscopy. PMID:29163958

  6. A dual-action, low-volume bowel cleanser administered the day before colonoscopy: results from the SEE CLEAR II study.

    PubMed

    Katz, Philip O; Rex, Douglas K; Epstein, Michael; Grandhi, Nav K; Vanner, Stephen; Hookey, Lawrence C; Alderfer, Vivian; Joseph, Raymond E

    2013-03-01

    Optimal bowel preparation is vital for the efficacy and safety of colonoscopy. The inconvenience, discomfort, required consumption of large volumes of product, and potential adverse effects associated with some bowel preparations deter patients from colonoscopy and may provide inadequate cleansing. A dual-action, non-phosphate, natural orange-flavored, low-volume preparation containing sodium picosulfate and magnesium citrate (P/MC) is currently being reviewed for bowel cleansing. This was a phase 3, randomized, multicenter, assessor-blinded, prespecified non-inferiority, head-to-head study to investigate the efficacy, safety, and tolerability of day-before administration of P/MC vs. 2L polyethylene glycol solution and two 5-mg bisacodyl tablets (2L PEG-3350 and bisacodyl tablets (HalfLytely and Bisacodyl Tablets Bowel Prep Kit)) in adult patients preparing for colonoscopy (SEE CLEAR II Study). The primary objective of the study was to demonstrate the non-inferiority of P/MC to 2L PEG-3350 and bisacodyl tablets in overall colon cleansing using a modified Aronchick scale. In addition, efficacy in the ascending, mid (transverse and descending), and recto-sigmoid segments of colon was evaluated using a modified Ottawa scale. Patient acceptability and tolerability of the bowel preparations were assessed via a standard questionnaire. Safety was assessed based on the monitoring of adverse events (AEs) and meaningful findings on clinical evaluations including physical examinations, vital sign measurements, and electrocardiograms (ECGs). A total of 603 patients were randomized to receive either P/MC (n = 300) or 2L PEG-3350 and bisacodyl tablets (n = 303). Based on the Aronchick scale, successful overall cleansing was similar in patients receiving P/MC (83.0%) and patients receiving 2L PEG-3350 and bisacodyl tablets (79.7%). P/MC demonstrated non-inferiority to 2L PEG-3350 and bisacodyl tablets in overall cleansing of the colon, as measured by the Aronchick scale. Similarly, the efficacy of P/MC, as measured by the Ottawa scale, was non-inferior to 2L PEG-3350 and bisacodyl tablets in cleansing the ascending, mid, and recto-sigmoid segments of the colon. Patient-reported acceptability and tolerability for each item examined on the questionnaire was significantly greater for P/MC compared with 2L PEG-3350 and bisacodyl tablets (P<0.0001).Treatment-emergent AEs related to the bowel preparation reported by 1% of patients receiving P/MC or 2L PEG-3350 and bisacodyl tablets were nausea (3.0% vs. 4.3%), vomiting (1.4% vs. 2.0%), and headache (2.7% vs. 1.7%). No clinically meaningful changes were noted in either treatment arm in data collected from physical examinations, vital sign measurements, and ECGs. When administered as a day-before dose, the bowel cleansing effects of P/MC were non-inferior compared with 2L PEG-3350 and bisacodyl tablets using the clinician-rated Aronchick and Ottawa scales. Treatment acceptability was significantly more favorable in patients receiving P/MC than in patients receiving 2L PEG-3350 and bisacodyl tablets.

  7. Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy.

    PubMed

    Valiante, Flavio; Bellumat, Angelo; De Bona, Manuela; De Boni, Michele

    2013-09-07

    To compare the bowel cleansing efficacy, tolerability and acceptability of split 2-L polyethylene glycol (PEG)-citrate-simethicone (PEG-CS) plus bisacodyl (BIS) vs 4-L PEG for fecal occult blood test-positive screening colonoscopy. This was a randomised, observer-blind comparative study. Two hundred and sixty-four subjects underwent screening colonoscopy (mean age 62.5 ± 7.4 years, male 61.7%). The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations. BIS plus PEG-CS: 3 tablets of 5-mg BIS at 16:00, PEG-CS 1-L at 19:00 and 1-L at 7:00, 4-L PEG: 3-L at 17:00, and 1-L at 7:00. Colonoscopy was carried out after 11:00, at least 3 h after the completion of bowel preparation. Bowel cleansing was evaluated using the Harefield Cleansing Scale. Bowel preparation was successful for 92.8% of subjects in the PEG-CS group and for 92.1% of subjects in the 4-L PEG (RR = 1.01; 95%CI: 0.94-1.08). BIS + PEG-CS was better tolerated than 4-L PEG. A greater rate of patients in the BIS + PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group. Subjects in the BIS + PEG-CS group rated the prep as good or satisfactory in 90.6% as compared to 77% in the 4-L PEG (P = 0.003). Subjects receiving BIS + PEG-CS stated they fully adhered to instructions drinking all the 2-L solution in 97.1% compared with 87.3% in the 4-L PEG (P = 0.003). BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split 4-L PEG for screening colonoscopy. This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy.

  8. [Cleansing effect of two micromotor-driven endodontic handpieces.II. Effect of various rinsing solutions on the cleansing effect of the handpieces].

    PubMed

    Bartha, K; Rocca, J P

    1993-12-01

    The cleansing effectivity of citric acid solution was significantly better than that of Neomagnol both with respect to the removal of the Smear Layer (SL) and to the number of visible dentinal tubular orifices, however a complete elimination of the SL could not be obtained. Neomagnol seemed to be more effective in the removal of superficial debris and tissue-remnants.

  9. A study to define a set of requirements for cleansing agents for use in the Space Station whole body shower

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The objective of this research is to define a set of requirements for a whole body cleansing agent to be used in the Space Station Whole Body Shower System. In addition, cleansing agent candidates are to be identified that are likely to satisfy requirements defined in the first part of the study. It is understood that the main reason for having a Whole Body Shower is to satisfy the physiological, psychological and social needs of the crew throughout the duration of duty in the Space Station. The cleansing agent must also be compatible with the vortex water/gas separator and the water reclamation system. To accomplish these goals the study was divided into six tasks.

  10. Tagging-based, electronically cleansed CT colonography: evaluation of patient comfort and image readability.

    PubMed

    Zalis, Michael E; Perumpillichira, James J; Magee, Cordula; Kohlberg, Gavriel; Hahn, Peter F

    2006-04-01

    To prospectively compare the homogeneity, adequacy, and patient acceptance of nonionic iodine-based regimens with those of a barium-based regimen for computed tomographic (CT) colonography with electronic subtraction cleansing. After institutional review board approval and informed consent were obtained, 68 subjects (41 men (60%) men, 27 (40%) women; mean age, 60 years +/- 6 [standard deviation]) with average or moderate risk factors for development of colorectal carcinoma were recruited and placed into three study groups. Group 1 (n = 25) ingested 150-mL aliquots of 2% barium sulfate suspension with meals and snacks for 48 hours prior to imaging, without other diet modification or a cathartic. Group 2 (n = 21) ingested 10-mL aliquots of nonionic iodinated contrast material (iopromide) with a concentration of 300 mg per milliliter with meals and snacks for 2 days before imaging, without diet modification or a cathartic. Group 3 (n = 22) ingested nonionic iodinated contrast material (iohexol) with a concentration of 300 mg per milliliter with meals and snacks for 2 days before imaging and ingested 34 g of magnesium citrate the evening prior to imaging. CT colonography was also performed on 10 control subjects who ingested polyethylene glycol electrolyte solution prior to imaging. Subjective and numerical measures of bowel preparation quality, homogeneity, and patient comfort among the noncathartic and cathartic cohorts were compared with nonparametric analysis of variance, the Fisher exact test, and the F test, as appropriate. The study was HIPAA compliant. Study subjects who received tagging preparations reported significantly improved discomfort scores when compared with those of the control subjects (P < .05, each comparison). There was no significant difference in discomfort scores among groups 1, 2, and 3. For each reader, scores of subtracted image readability were highest for group 3. Dichotomized rates of preparation "success" were also greatest for group 3. In this series, the patient discomfort scores were significantly improved with tagging preparations for CT colonography. Nonionic iodinated contrast material in conjunction with a hyperosmotic laxative (magnesium citrate) was associated with the best subjective and numerical indices of readability. (c) RSNA, 2006.

  11. Washing away your sins will set your mind free: physical cleansing modulates the effect of threatened morality on executive control.

    PubMed

    Kalanthroff, Eyal; Aslan, Chen; Dar, Reuven

    2017-01-01

    The effect of threatened morality on negative emotions and on altruistic behaviour has been shown to diminish following physical cleansing (hand-washing). We hypothesised that threatened morality will broadly impair the executive control system, and that physical cleansing will moderate this detrimental effect. Thirty-seven participants were asked to write about an immoral deed they had committed, whereupon half of them were allowed to wipe their hands. Three executive control tasks-Stroop, stop-signal, and object interference-were then administered to all participants. Participants who had not wiped their hands, but not those who did, demonstrated impaired performance, compared to hand-washing controls, in all three tasks. We conclude that threatened morality has a detrimental effect on executive control, specifically on conflict monitoring and response inhibition, and that physical cleansing "frees" this system, counteracting the detrimental effects of morality threats. We discuss possible implications for obsessive-compulsive disorder, which is characterised by deficient executive control and in which both threatened morality and physical cleansing are central concerns.

  12. Polyethylene glycol 3350 based colon cleaning protocol: 2 d vs 4 d head to head comparison.

    PubMed

    Elitsur, Rotem; Butcher, Lisa; Vicki, Lund; Elitsur, Yoram

    2013-04-16

    To compare between 2 and 4 d colon cleansing protocols. Children who were scheduled for colonoscopy procedure (2010-2012) for various medical reasons, were recruited from the pediatric gastroenterology clinic at Marshall University School of Medicine, Huntington, WV. Exclusion criteria were patients who were allergic to the medication used in the protocols [polyethylene glycol (PEG) 3350, Bisacodyl], or children with metabolic or renal diseases. Two PEG 3350 protocols for 4 d (A) and 2 d (B) were prescribed as previously described. A questionnaire describing the volume of PEG consumed, clinical data, and side effects were recorded. Colon preparation was graded by two observers according to previously described method. Rate of adequate colon preparation. A total of 78 patients were considered for final calculation (group A: 40, group B: 38). Age and stool consistency at the last day was comparable in both groups, but the number of stools/day was significantly higher in group B (P = 0.001). Adequate colon preparation was reached in 57.5% (A) and 73.6% (B), respectively (P = 0.206). Side effects were minimal and comparable in both groups. There was no difference in children's age, stool characteristics, or side effects between the children with adequate or inadequate colon preparation. Correlation and agreement between observers was excellent (Pearson correlation = 0.972, kappa = 1.0). No difference between protocols was observed, but the 2 d protocol was superior for its shorter time. Direct comparison between different colon cleansing protocols is crucial in order to establish the "gold standard" protocol for children.

  13. A critical evaluation and a search for the ideal colonoscopic preparation.

    PubMed

    Arora, Manish; Senadhi, Viplove; Arora, Deepika; Weinstock, Joyce; Dubin, Ethan; Okolo, Patrick I; Dutta, Sudhir K

    2013-04-01

    The aim of this study was to evaluate the efficacy of various bowel preparations in accomplishing colonic cleansing for optimal mucosal visualization during colonoscopy. The study included a cohort of 980 patients who underwent colonoscopy at our endoscopy center within the last 3 years. All of the study patients were subdivided into four groups. Each group included 245 patients, all receiving a different type of bowel preparation. The bowel preparations used in this study included: magnesium citrate (Group I), a combination of oral sodium phosphate (fleets) and powder PEG-3350 (Group II), powder polyethylene glycol-3350 (PEG-3350 powder for Group III), and oral sodium phosphate (fleets for Group IV). A Colon Prep Score (CPS) was devised to compare the quality of the different bowel preparations used. The colonoscopy results from all of these patients were tabulated and analyzed statistically and expressed as mean ± 1 standard deviation. Statistical analysis was performed using a one way ANOVA with Holm-Sidak method for intergroup analysis. Group I patients received magnesium citrate and had a mean CPS ± 1 SD of 3.11 ± 0.91. Group II patients (fleets and powder PEG-3350 combination) achieved a CPS of 3.37 ± 1.16. The patients in Group III (powder PEG-3350) actually showed the highest mean CPS of 3.44 ± 1.12. Group IV patients who used oral sodium phosphate alone reached a mean CPS of 3.23 ± 1.01. Group III patients (powder PEG-3350 only) demonstrated a statistically higher CPS (P<0.0006) in colon cleansing as compared to Group I patients (magnesium citrate). Similarly, Group II patients (oral sodium phosphate and powder PEG-3350 combination) also showed improved colon cleansing statistically (P<0.006) as compared to Group I patients (magnesium citrate). Overall, all four colon preparations achieved an average CPS greater than 3.0 indicating clinically adequate colonic cleansing. However, powder PEG-3350 alone and in combination with oral sodium phosphate was observed to be statistically superior to magnesium citrate, when used for colon preparation for colonoscopy. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  14. Paraneoplastic Syndromes

    MedlinePlus

    ... cortisone or prednisone, high-dose intravenous immunoglobulin, or irradiation. Plasmapheresis, a process that cleanses antibodies from the ... cortisone or prednisone, high-dose intravenous immunoglobulin, or irradiation. Plasmapheresis, a process that cleanses antibodies from the ...

  15. Spatial Data from Transportation Studies and Surveys | Transportation

    Science.gov Websites

    transportation studies and surveys, submit an application for approval to connect to a restricted secure portal environment. For a list of studies and surveys, see cleansed data. Application Process For accessing spatial data, learn about the application and approval process. If you'd like to apply to access the spatial

  16. Addition of senna improves quality of colonoscopy preparation with magnesium citrate.

    PubMed

    Vradelis, Stergios; Kalaitzakis, Evangelos; Sharifi, Yalda; Buchel, Otto; Keshav, Satish; Chapman, Roger W; Braden, Barbara

    2009-04-14

    To prospectively investigate the effectiveness and patient's tolerance of two low-cost bowel cleansing preparation protocols based on magnesium citrate only or the combination of magnesium citrate and senna. A total of 342 patients who were referred for colonoscopy underwent a colon cleansing protocol with magnesium citrate alone (n = 160) or magnesium citrate and senna granules (n = 182). The colonoscopist rated the overall efficacy of colon cleansing using an established score on a 4-point scale. Patients were questioned before undergoing colonoscopy for side effects and symptoms during bowel preparation. The percentage of procedures rescheduled because of insufficient colon cleansing was 7% in the magnesium citrate group and 4% in the magnesium citrate/senna group (P = 0.44). Adequate visualization of the colonic mucosa was rated superior under the citramag/senna regimen (P = 0.004). Both regimens were well tolerated, and did not significantly differ in the occurrence of nausea, bloating or headache. However, abdominal cramps were observed more often under the senna protocol (29.2%) compared to the magnesium citrate only protocol (9.9%, P < 0.0003). The addition of senna to the bowel preparation protocol with magnesium citrate significantly improves the cleansing outcome.

  17. Addition of senna improves quality of colonoscopy preparation with magnesium citrate

    PubMed Central

    Vradelis, Stergios; Kalaitzakis, Evangelos; Sharifi, Yalda; Buchel, Otto; Keshav, Satish; Chapman, Roger W; Braden, Barbara

    2009-01-01

    AIM: To prospectively investigate the effectiveness and patient’s tolerance of two low-cost bowel cleansing preparation protocols based on magnesium citrate only or the combination of magnesium citrate and senna. METHODS: A total of 342 patients who were referred for colonoscopy underwent a colon cleansing protocol with magnesium citrate alone (n = 160) or magnesium citrate and senna granules (n = 182). The colonoscopist rated the overall efficacy of colon cleansing using an established score on a 4-point scale. Patients were questioned before undergoing colonoscopy for side effects and symptoms during bowel preparation. RESULTS: The percentage of procedures rescheduled because of insufficient colon cleansing was 7% in the magnesium citrate group and 4% in the magnesium citrate/senna group (P = 0.44). Adequate visualization of the colonic mucosa was rated superior under the citramag/senna regimen (P = 0.004). Both regimens were well tolerated, and did not significantly differ in the occurrence of nausea, bloating or headache. However, abdominal cramps were observed more often under the senna protocol (29.2%) compared to the magnesium citrate only protocol (9.9%, P < 0.0003). CONCLUSION: The addition of senna to the bowel preparation protocol with magnesium citrate significantly improves the cleansing outcome. PMID:19360920

  18. The Effect of Four Commonly used Root Canal Irrigants on the Removal of Smear Layer: An In-vitro Scanning Electron Microscope Study.

    PubMed

    Kumar, Pawan; Prasad, Narayana; Darawade, Ashish; Bhagat, Shresht Kumar; Narayana, Narayana; Darawade, Pradyma

    2015-09-01

    The objective of this study was to compare the efficiency of four commonly used chemicals in their ability to remove smear layer after instrumentation using scanning electron microscope (SEM). Seventy-five extracted single canaled teeth of roots ranging 10-12 mm in length were used for the study. Teeth were divided into 4 study groups and 1 control group of 15 teeth each. Standard access to the pulp chambers were performed with diamond burs. The lengths of the teeth were determined by the introduction of a size 15 K-file into the root canal until the tip reached the apical foramen. The working length for preparation of the canal is set 0.5 mm shorter than the measurement. Irrigation was performed using 2 ml of irrigant for every instrument change and finally rinsed using 5 ml of the respective solutions. The roots were then split with a chisel and hammer. One-half of each tooth was selected and prepared for SEM examination. After assembly on coded stubs, the specimens were placed in a vacuum chamber and sputter-coated with a 300 Å gold layer. The specimens were then analyzed using a Philips SEM XL 30. The dentinal wall of the cervical, middle and apical thirds was observed at magnifications of up to ×1000 for the presence/absence of smear layer and visualization of the entrance to dentinal tubules. Photomicrographs (×1000) of these areas on each of the coronal, middle and apical thirds were made Data were analyzed using Kruskal-Wallis test and Mann-Whitney U test. SEM study done on these prepared teeth with the popularly used four chemicals, namely, 3% NaOCl (Group A), 3% NaOCl followed by 17% ethylene diamine-tetra-acetic acid (Group B), 0.2% chlorhexidine (Group C) and 3% NaOCl followed by MTAD (Group D), with distilled water (Group E) which is used as control, revealed that NaOCl showed statistically significant, better cleansing effect than distilled water. Chlorhexidine and NaOCl showed equal kind of efficacy but were statistically significant, with lower efficacy than MTAD. It may be concluded that MTAD appears to be the most effective solution compared to the rest. The study demonstrated that MTAD as a final rinse after the entire instrumentation with 3% NaOCl as irrigant provided the best cleansing in all parts of the root canal system. The smear layer has been shown to hinder the penetration of intracanal disinfectants and sealers into dentinal tubules and has the potential of compromising the seal of the root filling. Degradation of the smear layer after treatment may contribute to leakage and reinfection of the root canal space. Removal of the smear layer reduced the penetration of bacteria through the root canal system after root filling.

  19. Polyethylene glycol 3350 based colon cleaning protocol: 2 d vs 4 d head to head comparison

    PubMed Central

    Elitsur, Rotem; Butcher, Lisa; Vicki, Lund; Elitsur, Yoram

    2013-01-01

    AIM: To compare between 2 and 4 d colon cleansing protocols. METHODS: Children who were scheduled for colonoscopy procedure (2010-2012) for various medical reasons, were recruited from the pediatric gastroenterology clinic at Marshall University School of Medicine, Huntington, WV. Exclusion criteria were patients who were allergic to the medication used in the protocols [polyethylene glycol (PEG) 3350, Bisacodyl], or children with metabolic or renal diseases. Two PEG 3350 protocols for 4 d (A) and 2 d (B) were prescribed as previously described. A questionnaire describing the volume of PEG consumed, clinical data, and side effects were recorded. Colon preparation was graded by two observers according to previously described method. Main outcome measurements: Rate of adequate colon preparation. RESULTS: A total of 78 patients were considered for final calculation (group A: 40, group B: 38). Age and stool consistency at the last day was comparable in both groups, but the number of stools/day was significantly higher in group B (P = 0.001). Adequate colon preparation was reached in 57.5% (A) and 73.6% (B), respectively (P = 0.206). Side effects were minimal and comparable in both groups. There was no difference in children’s age, stool characteristics, or side effects between the children with adequate or inadequate colon preparation. Correlation and agreement between observers was excellent (Pearson correlation = 0.972, kappa = 1.0). CONCLUSION: No difference between protocols was observed, but the 2 d protocol was superior for its shorter time. Direct comparison between different colon cleansing protocols is crucial in order to establish the “gold standard” protocol for children. PMID:23596539

  20. Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy

    PubMed Central

    Valiante, Flavio; Bellumat, Angelo; De Bona, Manuela; De Boni, Michele

    2013-01-01

    AIM: To compare the bowel cleansing efficacy, tolerability and acceptability of split 2-L polyethylene glycol (PEG)-citrate-simethicone (PEG-CS) plus bisacodyl (BIS) vs 4-L PEG for fecal occult blood test-positive screening colonoscopy. METHODS: This was a randomised, observer-blind comparative study. Two hundred and sixty-four subjects underwent screening colonoscopy (mean age 62.5 ± 7.4 years, male 61.7%). The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations. Interventions: BIS plus PEG-CS: 3 tablets of 5-mg BIS at 16:00, PEG-CS 1-L at 19:00 and 1-L at 7:00, 4-L PEG: 3-L at 17:00, and 1-L at 7:00. Colonoscopy was carried out after 11:00, at least 3 h after the completion of bowel preparation. Bowel cleansing was evaluated using the Harefield Cleansing Scale. RESULTS: Bowel preparation was successful for 92.8% of subjects in the PEG-CS group and for 92.1% of subjects in the 4-L PEG (RR = 1.01; 95%CI: 0.94-1.08). BIS + PEG-CS was better tolerated than 4-L PEG. A greater rate of patients in the BIS + PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group. Subjects in the BIS + PEG-CS group rated the prep as good or satisfactory in 90.6% as compared to 77% in the 4-L PEG (P = 0.003). Subjects receiving BIS + PEG-CS stated they fully adhered to instructions drinking all the 2-L solution in 97.1% compared with 87.3% in the 4-L PEG (P = 0.003). CONCLUSION: BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split 4-L PEG for screening colonoscopy. This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy. PMID:24023492

  1. The effect of denture cleansing solutions on the retention of pink locator attachments after multiple pulls: an in vitro study.

    PubMed

    You, Wenguang; Masri, Radi; Romberg, Elaine; Driscoll, Carl F; You, Tao

    2011-08-01

    The effect of denture cleansing solutions and multiple pulls on the retention of pink Locator patrices was studied. Five groups of pink Locator attachments (3.0 lb. Light Retention replacement patrix attachments; five in each group) were soaked for the equivalent of 6 months of clinical use in the following solutions: water (control), Efferdent, Polident Overnight, 6.15% sodium hypochlorite (NaOCL, 1:10 dilution), and Listerine mouthwash. A universal testing machine set at a 2 in/min crosshead speed was used to perform 548 pulls (548 cycles of insertion and removal). The reduction in load to dislodgement (retention) after the initial pull and the final pull and the percent reduction in retention after 6 months were compared between the groups using a one-way ANOVA followed by Tukey's Honestly Significant Difference (HSD) Test (α= 0.05). Denture cleansing solutions significantly reduced the retentive values of pink Locator attachments after the initial pull (F = 17.435, p < 0.0001). The retentive values of Efferdent, Listerine, Polident Overnight, and water were significantly higher than the retentive value of the attachments soaked in NaOCl. After 6 months of simulated use (548 pulls), the four denture cleansing solutions had significant effects on the retentive values of pink Locator attachments (F = 5.855, p = 0.003). The retentive values for attachments soaked in NaOCl (7.29 ± 1.0 N) were significantly lower than those of attachments soaked in Listerine (15.82 ± 4.7 N) and in Polident Overnight (14.41 ± 3.6 N). These cleansing solutions also had a significant effect on the percentage of retention lost (F = 3.271, p = 0.032). The loss of retention in attachments soaked in Listerine (29 ± 9%) was significantly lower than attachments soaked in water (53 ± 12%). The loss of retention in attachments soaked in Efferdent was 49 ± 9%; in Polident Overnight, 34 ± 18%; and in NaOCl, 42 ± 11%. There was no significant difference in the percentage of retention loss between water, Efferdent, NaOCl, and Polident Overnight. There was also no significant difference in the percentage of retention loss between Efferdent, NaOCl, Polident Overnight, and Listerine. NaOCl significantly decreased the retentive value of Locators. Therefore, it should not be routinely recommended for use as a denture cleanser. Listerine significantly increased the retention of the Locator attachments; however, it is premature to recommend Listerine for use as a denture cleanser. © 2011 by The American College of Prosthodontists.

  2. Budget-impact model for colonoscopy cost calculation and comparison between 2 litre PEG+ASC and sodium picosulphate with magnesium citrate or sodium phosphate oral bowel cleansing agents.

    PubMed

    Gruss, H-J; Cockett, A; Leicester, R J

    2012-01-01

    With the availability of several bowel cleansing agents, physicians and hospitals performing colonoscopies will often base their choice of cleansing agent purely on acquisition cost. Therefore, an easy to use budget impact model has been developed and established as a tool to compare total colon preparation costs between different established bowel cleansing agents. The model was programmed in Excel and designed as a questionnaire evaluating information on treatment costs for a range of established bowel cleansing products. The sum of costs is based on National Health Service reference costs for bowel cleansing products. Estimations are made for savings achievable when using a 2-litre polyethylene glycol with ascorbate components solution (PEG+ASC) in place of other bowel cleansing solutions. Test data were entered into the model to confirm validity and sensitivity. The model was then applied to a set of audit cost data from a major hospital colonoscopy unit in the UK. Descriptive analysis of the test data showed that the main cost drivers in the colonoscopy process are the procedure costs and costs for bed days rather than drug acquisition costs, irrespective of the cleansing agent. Audit data from a colonoscopy unit in the UK confirmed the finding with a saving of £107,000 per year in favour of PEG+ASC when compared to sodium picosulphate with magnesium citrate solution (NaPic+MgCit). For every patient group the model calculated overall cost savings. This was irrespective of the higher drug expenditure associated with the use of PEG+ASC for bowel preparation. Savings were mainly realized through reduced costs for repeat colonoscopy procedures and associated costs, such as inpatient length of stay. The budget impact model demonstrated that the primary cost driver was the procedure cost for colonoscopy. Savings can be realized through the use of PEG+ASC despite higher drug acquisition costs relative to the comparator products. From a global hospital funding perspective, the acquisition costs of bowel preparations should not be used as the primary reason to select the preferred treatment agent, but should be part of the consideration, with an emphasis on the clinical outcome.

  3. Randomized controlled trial of 3 days fasting and oral senna, combined with mannitol and simethicone, before capsule endoscopy.

    PubMed

    Chen, Hong-Bin; Lian-Xiang, Peng; Yue, Huang; Chun, Huang; Shu-Ping, Xiao; Rong-Pang, Lin; Xiao-Zong, Wang; Xiao-Lin, Li

    2017-10-01

    The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ = 22.470, P = .000; χ = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ = 12.390, P = .000, χ = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ = 0.678, P = .509). Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine.

  4. Stool consistency and stool frequency are excellent clinical markers for adequate colon preparation after polyethylene glycol 3350 cleansing protocol: a prospective clinical study in children.

    PubMed

    Safder, Shaista; Demintieva, Yulia; Rewalt, Mary; Elitsur, Yoram

    2008-12-01

    Colon preparation for a colonoscopy in children is a difficult task because of the unpalatable taste and large volume of cleansing solution that needs to be consumed to ensure a clean colon. Consequently, an unprepared colon frequently occurs in routine practices, which causes early termination and a repeated procedure. (1) To assess the effectiveness of polyethylene glycol solution (PEG 3350) in preparing the colon of children scheduled for a colonoscopy and (2) to investigate clinical markers associated with an adequate colon preparation before a colonoscopy. A total of 167 children scheduled for a colonoscopy. In a prospective study, children scheduled for a colonoscopy were given PEG 3350 solution (1.5 g/kg per day, up to 100 g/d) over a 4-day preparation period. Each day, a simple questionnaire that documents the amount of liquid consumed, adverse effects, and the number and consistency of stool was completed by the parents. After a colonoscopy procedure, the colon preparation was assigned a number grade. The data were later assessed and were compared to determine the association between the grade of cleansing and the frequency and/or consistency of stool during preparation. Colon preparation was completed in 149 children, 133 of whom were adequately prepared. Inadequate preparation was found in 16 children; the procedure was terminated prematurely in 2 of these patients because of unacceptable conditions. No significant adverse effects were noted. A number of >or=5 stools/d, and liquid stool consistency in the last 2 days of preparation were associated with adequate colon preparation. PEG 3350 solution is safe, efficacious, and tolerable for children. Stool frequency and consistency in the last 2 days of preparation were excellent markers (positive predictive value 91%-95%), which predict an adequately clean colon before a colonoscopy in children.

  5. Genital region cleansing wipes: Effects on urine culture contamination.

    PubMed

    Selek, Mehmet Burak; Bektöre, Bayhan; Sezer, Ogün; Kula Atik, Tuğba; Baylan, Orhan; Özyurt, Mustafa

    2017-01-30

    Urine culture is the gold standard test for revealing the microbial agent causing urinary tract infection (UTI). Culture results are affected by sampling techniques; improper sampling leads to contamination of urine and thus contamination of the culture with urogenital flora. We aimed to evaluate the effect of urogenital cleansing, performed with chlorhexidine-containing genital region cleansing wipes (GRCW) on contamination rates. A total of 2,665 patients with UTI-related complaints and with urine culture requests from various outpatient clinics were enrolled in the study. Of the patients, 1,609 in the experimental group used GRCW before sampling, while 1,046 in the control group did not use any wipes. The contamination rate in the experimental group patients was 7.7%, while it was 15.8% in the control group. Contamination rates were significantly higher in the control group than in the experimental group for both women and men. Contamination rates for children and adults were also significantly lower in the experimental group than in the control group. Our study, conducted in a large population, showed that the use of chlorhexidine-containing cleansing wipes significantly reduced urine culture contamination rates in both genders, in both child and adult age groups. Using GRCW, collection of urine after urogenital area cleansing will decrease the contamination problem.

  6. The Promise and the Peril of the Responsibility to Protect

    DTIC Science & Technology

    2012-02-21

    ORGANIZATION NAME(S) AND ADDRESS(ES) AND ADDRESS(ES) 8 . PERFORMING ORGANIZATION REPORT NUMBER Colonel (Retired) Allen D. Raymond U.S. Army...protect populations from genocide , war crimes, ethnic cleansing and crimes against humanity. Serious differences in how sovereign governments and...rebellion as a case study of the use of force under the auspices of The Responsibility to Protect. 15. SUBJECT TERMS Genocide , War Crimes, Ethnic

  7. Treatment of Biofouling in Internal Seawater Systems - Phase 2

    DTIC Science & Technology

    2007-11-01

    Denture Cleansing Tablets. Issue Date: Feb 2006. Reckitt Benckiser 12 In the first instance, in July 2006, mussels were transferred directly to an...Denture Cleansing Tablets (Reckit Benckiser , West Ryde) Chemical composition11: Potassium peroxymonosulfate 10-30% Sodium carbonate ᝺% Citric

  8. Optimise inlet condition and design parameters of a new sewer overflow screening device using numerical model.

    PubMed

    Aziz, M A; Imteaz, M A; Huda, Nazmul; Naser, J

    2014-01-01

    After heavy rainfall, sewer overflow spills to receiving water bodies cause serious concern for the environment, aesthetics and public health. To overcome these problems this study investigated a new self-cleansing sewer overflow screening device. The device has a sewer overflow chamber, a rectangular tank and a slotted ogee weir to capture the gross pollutants. To design an efficient screening device a numerical computational fluid dynamic (CFD) model was used. A plausibility check of the CFD model was done using a one-dimensional analytical model. Results showed that an inlet parallel to the weir ensured better self-cleansing than an inlet perpendicular to the weir. Perforations should be at the bottom of the weir to get increased velocity and shear stress to create a favourable self-cleaning effect of the screening device. Increasing inlet length from 0.3 to 1.5 m reduced wave reflection up to 10%, which increased flow uniformity downstream and improved self-cleansing effect. The orientation of the ogee weir with the rectangular tank was found most uniform with a 1:3 (horizontal:vertical) slope. These results will help to maximise functional efficiency of the new sewer overflow screening device. Otherwise it would be too expensive to alter after installation and at times difficult to customise accordingly to existing urban drainage systems.

  9. Efficacy and safety of sodium phosphate for colon cleansing in type 2 diabetes mellitus.

    PubMed

    Ozturk, Nevin Akcaer; Gokturk, Huseyin Savas; Demir, Mehmet; Unler, Gulhan Kanat; Gur, Gurden; Yilmaz, Ugur

    2010-11-01

    The need for colonoscopy is common among diabetic patients. However, there are no standards per se for bowel preparation in patients with type 2 diabetes. In this study, we evaluated the efficacy, safety, and tolerability of sodium phosphate (NaP), and the quality of bowel cleansing in relation to glycemic control and late complications. A total of 50 consecutive type 2 diabetic patients and 50 non-diabetic patients underwent bowel preparation by NaP. Fasting blood glucose, sodium (Na), potassium (K), calcium (Ca), phosphorus (P), magnesium, and creatinine levels were measured on the procedure day. Patients were given a tolerability questionnaire regarding symptoms. With regard to bowel preparation quality, optimal bowel cleansing was achieved in 35 (70%) diabetic and 47 (94%) non-diabetic patients (P = 0.002). Abdominal pain or discomfort during and an hour after the procedure was similar in both groups (P >0.05). The changes in Na, K, Ca, P and creatinine levels after NaP use did not reach statistical significance between the groups (P >0.05). In the diabetic patients, there was a significant correlation between the quality of bowel cleansing and mean age, duration of diabetes mellitus, level of hemoglobin A1c (HbA1c), fasting blood glucose level, and diabetic late complications (P <0.05). These data suggest that NaP is safe and tolerable in diabetic patients, but the quality of bowel cleansing is worse than in non-diabetic patients. These observations support the concept that the quality of bowel cleansing in those with type 2 diabetes is closely related to the duration and regulation of the disease and the presence of late complications.

  10. Impact of 4.0% chlorhexidine cleansing of the umbilical cord on mortality and omphalitis among newborns of Sylhet, Bangladesh: design of a community-based cluster randomized trial.

    PubMed

    Mullany, Luke C; El Arifeen, Shams; Winch, Peter J; Shah, Rasheduzzaman; Mannan, Ishtiaq; Rahman, Syed M; Rahman, Mohammad R; Darmstadt, Gary L; Ahmed, Saifuddin; Santosham, Mathuram; Black, Robert E; Baqui, Abdullah H

    2009-10-21

    The World Health Organization recommends dry cord care for newborns but this recommendation may not be optimal in low resource settings where most births take place in an unclean environment and infections account for up to half of neonatal deaths. A previous trial in Nepal indicated that umbilical cord cleansing with 4.0% chlorhexidine could substantially reduce mortality and omphalitis risk, but policy changes await additional community-based data. The Projahnmo Chlorhexidine study was a three-year, cluster-randomized, community-based trial to assess the impact of three cord care regimens on neonatal mortality and omphalitis. Women were recruited mid-pregnancy, received a basic package of maternal and neonatal health promotion messages, and were followed to pregnancy outcome. Newborns were visited at home by local village-based workers whose areas were randomized to either 1) single- or 2) 7-day cord cleansing with 4.0% chlorhexidine, or 3) promotion of dry cord care as recommended by WHO. All mothers received basic messages regarding hand-washing, clean cord cutting, and avoidance of harmful home-base applications to the cord. Death within 28 days and omphalitis were the primary outcomes; these were monitored directly through home visits by community health workers on days 1, 3, 6, 9, 15, and 28 after birth. Due to report in early 2010, the Projahnmo Chlorhexidine Study examines the impact of multiple or single chlorhexidine cleansing of the cord on neonatal mortality and omphalitis among newborns of rural Sylhet District, Bangladesh. The results of this trial will be interpreted in conjunction with a similarly designed trial previously conducted in Nepal, and will have implications for policy guidelines for optimal cord care of newborns in low resource settings in Asia. ClinicalTrials.gov (NCT00434408).

  11. The Moral Virtue of Authenticity: How Inauthenticity Produces Feelings of Immorality and Impurity.

    PubMed

    Gino, Francesca; Kouchaki, Maryam; Galinsky, Adam D

    2015-07-01

    The five experiments reported here demonstrate that authenticity is directly linked to morality. We found that experiencing inauthenticity, compared with authenticity, consistently led participants to feel more immoral and impure. This link from inauthenticity to feeling immoral produced an increased desire among participants to cleanse themselves and to engage in moral compensation by behaving prosocially. We established the role that impurity played in these effects through mediation and moderation. We found that inauthenticity-induced cleansing and compensatory helping were driven by heightened feelings of impurity rather than by the psychological discomfort of dissonance. Similarly, physically cleansing oneself eliminated the relationship between inauthenticity and prosocial compensation. Finally, we obtained additional evidence for discriminant validity: The observed effects on desire for cleansing were not driven by general negative experiences (i.e., failing a test) but were unique to experiences of inauthenticity. Our results establish that authenticity is a moral state--that being true to thine own self is experienced as a form of virtue. © The Author(s) 2015.

  12. Safety assessment of enzyme-containing personal cleansing products: exposure characterization and development of IgE antibody to enzymes after a 6-month use test.

    PubMed

    Kelling, C K; Bartolo, R G; Ertel, K D; Smith, L A; Watson, D D; Sarlo, K

    1998-02-01

    Enzyme-containing personal cleansing products were being considered for the consumer market. Although enzymes have been marketed safely for many years as ingredients in laundry products, their use in a personal cleansing application represented a new type of exposure for consumers that was not supported by the historical safety data. An exposure assessment and additional safety data would be needed before marketing to ensure consumer safety. The work in this paper was designed to evaluate the potential for inhalation exposure to the enzyme during use of this new product while showering. Then a clinical trial was conducted to determine whether or not the level, duration, and routes of exposure encountered during use of this product would induce a Type I sensitization response to the enzyme. Exposure was assessed during normal showering activities by collecting air samples with both high volume and personal samplers and quantitating enzyme levels with an ELISA. To assess the potential for sensitization, panelists were asked to use a prototype protease-containing bar product for all personal cleansing tasks and to keep a use diary reporting any associated symptoms. Physical and dermatologic examinations and skin prick tests with enzyme were conducted before the test commenced and at 2-month intervals. Exposure assessment results showed that airborne enzyme levels were primarily dependent on the concentration of the enzyme in the personal cleansing product. Mean values for total airborne enzyme protein ranged from 5.7 to 11.8 ng/m3 when enzyme concentration, time of use, and measurement technique remained constant. After 6 months of at-home product use, four of 61 test subjects using the enzyme-containing bar had positive skin prick test responses when tested with the enzyme. The skin prick test data were supplemented with serologic analyses, which detected IgE specific for the protease enzyme. None of these subjects showed any clinical symptoms indicative of allergic reaction. The ability of enzymes to induce development of allergic antibodies in this study led to the conclusion that this prototype enzyme-containing personal cleansing bar would represent an inappropriate use of enzymes in a consumer product application. The likelihood of both induction of an immunologic response and subsequent elicitation of allergy symptoms in a small but significant fraction of the user population was high. This finding resulted in the decision to halt further development of this prototype.

  13. Vaginal Practices among Women at High Risk of HIV Infection in Uganda and Tanzania: Recorded Behaviour from a Daily Pictorial Diary

    PubMed Central

    Francis, Suzanna C.; Baisley, Kathy; Lees, Shelley S.; Andrew, Bahati; Zalwango, Flavia; Seeley, Janet; Vandepitte, Judith; Ao, Trong T.; van de Wijgert, Janneke; Watson-Jones, Deborah; Kapiga, Saidi; Grosskurth, Heiner; Hayes, Richard J.

    2013-01-01

    Background Intravaginal practices (IVP) are highly prevalent in sub-Saharan African and have been implicated as risk factors for HIV acquisition. However, types of IVP vary between populations, and detailed information on IVP among women at risk for HIV in different populations is needed. We investigated IVP among women who practice transactional sex in two populations: semi-urban, facility workers in Tanzania who engage in opportunistic sex work; and urban, self-identified sex workers and bar workers in Uganda. The aim of the study was to describe and compare IVP using a daily pictorial diary. Methodology/Principal Findings Two hundred women were recruited from a HIV prevention intervention feasibility study in Kampala, Uganda and in North-West Tanzania. Women were given diaries to record IVP daily for six weeks. Baseline data showed that Ugandan participants had more lifetime partners and transactional sex than Tanzanian participants. Results from the diary showed that 96% of Tanzanian participants and 100% of Ugandan participants reported intravaginal cleansing during the six week study period. The most common types of cleansing were with water only or water and soap. In both countries, intravaginal insertion (e.g. with herbs) was less common than cleansing, but insertion was practiced by more participants in Uganda (46%) than in Tanzania (10%). In Uganda, participants also reported more frequent sex, and more insertion related to sex. In both populations, cleansing was more often reported on days with reported sex and during menstruation, and in Uganda, when participants experienced vaginal discomfort. Participants were more likely to cleanse after sex if they reported no condom use. Conclusions While intravaginal cleansing was commonly practiced in both cohorts, there was higher frequency of cleansing and insertion in Uganda. Differences in IVP were likely to reflect differences in sexual behaviour between populations, and may warrant different approaches to interventions targeting IVP. Vaginal practices among women at high risk in Uganda and Tanzania: recorded behaviour from a daily pictorial diary. PMID:23555618

  14. National Policy and the Post-Systemic Navy

    DTIC Science & Technology

    2013-01-01

    average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed...5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7...various kinds of good works , ranging from helping stop ethnic cleansing in Kosovo to assisting victims of tsunamis in Indonesia and Japan, not to

  15. Laboratory investigation of the efficacy of holmium:YAG laser irradiation in removing intracanal debris

    NASA Astrophysics Data System (ADS)

    Nuebler-Moritz, Michael; Gutknecht, Norbert; Sailer, Hermann F.; Hering, Peter; Prettl, Wilhelm

    1997-05-01

    Current endodontic therapy involves debridement and disinfection of the root canal by means of mechanical instrumentation and chemical irrigation. However, several studies have shown that these techniques fail to achieve complete cleansing. Recently, lasers have been suggested for use within root canals. This study was conducted to determine the efficacy of Holmium:YAG laser irradiation in removing intracanal debris and smear layer. Root canal surfaces of freshly-extracted human teeth were exposed to pulsed Ho:YAG laser radiation. Subsequently, laser induced structural changes were investigated using scanning electron microscopy. Temperature measurements during irradiation were performed by means of thermocouples. The result of this survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment modalities. However, limitations exist with regard to circumscribed and well-quantified irradiation of root canal surfaces, due to the lack of perpendicular delivery of the laser beam. Additional studies will be required to develop suitable optical transmission systems, in order to achieve complete cleansing and to avoid damage to the periradicular tissues, respectively.

  16. Studies of contamination of three broiler breeder houses with Salmonella enteritidis before and after cleansing and disinfection.

    PubMed

    Davies, R H; Wray, C

    1996-01-01

    Three broiler breeder houses on three different sites were sampled before and after cleansing and disinfection. None of the farms achieved total elimination of Salmonella enteritidis from the poultry house environment but substantial improvements were seen when errors in the cleansing and disinfection protocol in the first house had been corrected. Fundamental errors such as over-dilution and inconsistent application of disinfectants were observed despite supervision of the process by technical advisors. In each of the three poultry units failure to eliminate a mouse population that was infected with S. enteritidis was likely to be the most important hazard for the next flock.

  17. [Comparative Study on Bowel Preparation Efficacy of Ascorbic Acid Containing Polyethylene Glycol by Adding Either Simethicone or 1 L of Water in Health Medical Examination Patients: A Prospective Randomized Controlled Study].

    PubMed

    Yeo, Se Hwan; Kwak, Jae Hoon; Kim, Yeo Un; Kwon, Tae Ho; Park, Jeong Bae; Park, Jun Hyung; Lee, Yong Kook; Lim, Yun Jeong; Yang, Chang Heon

    2016-04-25

    There are no studies that looked into the bubble eliminating efficacy of polyethylene glycol with ascorbic acid (PEGA), which has been one of the shortcomings of polyethylene glycol (PEG). In this study, we compared newly introduced PEGA regimen by adding either simethicone or 1 L of water. A prospective randomized controlled study was carried out at Dongguk Universtiy Gyeongju Hospital from July 2014 to September 2014. A total of 90 patients were randomly assigned to 3 groups; PEGA group (n=30) which served as control, simethicone addition group (n=30) to which simethicone 400 mg was additionally prescribed, and water addition group (n=30) to whom additional 1 L of water was given. Cleansing effectiveness, gas elimination efficacy, side effects, and patient satisfaction were compared between the groups. PEGA group demonstrated the highest cleansing effectiveness, but there was no statistically significant difference among the groups. Simethicone addition group showed significantly lesser amount of bubbles than the other groups (2.57±2.05 vs. 1.10±1.83 vs. 2.60±2.84, p=0.017). The rates of side effects in each group were 20.00% vs. 16.77% vs. 53.33%. Water addition group had significantly more side effects than the PEGA group and the simethicone addition group (p=0.003). The patient satisfaction score of each group was 3.37±0.85 vs. 3.73±0.74 vs. 3.20±0.66 with simethicone addition group showing significantly higher satisfaction than water addition group (p=0.020). PEGA bowel preparation agent showed satisfactory bowel cleansing despite the decrease in dosage, and addition of simethicone resulted in better bubble elimination.

  18. Condoms, Lubricants and Rectal Cleansing: Practices Associated with Heterosexual Penile-Anal Intercourse Amongst Participants in an HIV Prevention Trial in South Africa, Uganda and Zimbabwe

    PubMed Central

    Hartmann, Miriam; Montgomery, Elizabeth T.; Colvin, Christopher J.; Mensch, Barbara; van der Straten, Ariane

    2015-01-01

    We investigated condom and lubricant use, rectal cleansing and rectal gel use for penile-anal intercourse (PAI), during in-depth interviews with women from South Africa, Uganda and Zimbabwe who formerly participated in VOICE, a five-arm HIV prevention trial of two antiretroviral tablets and a vaginal gel. Few studies have addressed practices related to PAI among women; existing data from Africa on condom and lubricant use for PAI, as well as preparatory practices of PAI such as rectal cleansing, are limited to men who have sex with men. Women demonstrated a lack of awareness of HIV transmission risks of PAI and none of the participants reported using condom-compatible lubricants for PAI. Participants described a variety of preparatory rectal cleansing practices. Some participants disclosed rectal use of the vaginal study gel. Understanding practices related to PAI in Africa is critical to microbicide development, as these practices are likely to influence the acceptability, feasibility, and use of both vaginal and rectal microbicide products. PMID:26126586

  19. Bacterial vaginosis and vaginal yeast, but not vaginal cleansing, increase HIV-1 acquisition in African women.

    PubMed

    van de Wijgert, Janneke H H M; Morrison, Charles S; Cornelisse, Peter G A; Munjoma, Marshall; Moncada, Jeanne; Awio, Peter; Wang, Jing; Van der Pol, Barbara; Chipato, Tsungai; Salata, Robert A; Padian, Nancy S

    2008-06-01

    To evaluate interrelationships between bacterial vaginosis (BV), vaginal yeast, vaginal practices (cleansing and drying/tightening), mucosal inflammation, and HIV acquisition. A multicenter, prospective, observational cohort study was conducted, enrolling 4531 HIV-negative women aged 18 to 35 years attending family planning clinics in Zimbabwe and Uganda. Participants were tested for HIV and reproductive tract infections and were interviewed about vaginal practices every 3 months for 15 to 24 months. BV was measured by Gram stain Nugent scoring, vaginal yeast by wet mount, and mucosal inflammation by white blood cells on Gram stain. HIV incidence was 4.12 and 1.53 per 100 woman-years of follow-up in Zimbabwe and Uganda, respectively (a total of 213 incident infections). Women with BV or vaginal yeast were more likely to acquire HIV, especially if the condition was present at the same visit as the new HIV infection and the visit preceding it (hazard ratio [HR] = 2.50, 95% confidence interval [CI]: 1.68 to 3.72 and HR = 2.97, 95% CI: 1.67 to 5.28 for BV and yeast, respectively). These relationships did not seem to be mediated by mucosal inflammation. Vaginal drying/tightening was associated with HIV acquisition in univariate (HR = 1.49, 95% CI: 1.03 to 2.15) but not multivariate models. Vaginal cleansing was not associated with HIV acquisition. BV and yeast may contribute more to the HIV epidemic than previously thought.

  20. Design Concepts for Zero-G Whole Body Cleansing on ISS Alpha. Part 2; Individual Design Project; Degree awarded by International Space Univ., 1997

    NASA Technical Reports Server (NTRS)

    Mohanty, Susmita

    2001-01-01

    This document was originally published in 1997 as a International Space University Master of Space Studies student's project. While the specifics may be a little dated, the results gleaned are still relevant and valid. Johnson Space Center is now abuzz with preparations for the International Space Station. The work on the various systems for the U.S. Habitation Module will begin in 1998. As a prelude, the Flight Crew Support Division perceived the need to take a closer, more critical took at planning the Whole Body Cleansing function for ISS. This report is an endeavour to retrieve all data available on whole body cleansing mechanisms used, past and present, by the Russians and the Americans, analyze it and create design concepts for products/product systems for zero-g whole body cleansing on ISS Alpha, for typical duration of about 90 days. This report takes a close look at the Skylab collapsible shower, the Mir shower/sauna, the full body cleansing methods currently in use onboard the Space Shuttle and Mir and at the Whole Body Shower designed and tested for Space Station Freedom. It attempts to "listen" carefully to what the Mir astronauts (Norm Thagard, Shannon Lucid and John Blaha) have to say about their personal hygiene experiences during their recent stays on Mir. The findings in the report call for a change in paradigm. What is good for Earth conditions is not necessarily good for Zero-g! It concludes that a shower is not a good idea for the ISS. The final concept that is proposed reflects very strongly what the Mir astronauts would like to have and to use onboard a station like the ISS, The report concludes with directions of how to take the "idea" further and realize it in the form of a product system for Whole Body Cleansing onboard the ISS.

  1. A Prospective Randomized Controlled Trial of AJG522 versus Standard PEG + E as Bowel Preparation for Colonoscopy

    PubMed Central

    Sagawa, Toshihiko; Tomizawa, Taku; Mizuide, Masafumi; Yasuoka, Hidetoshi; Shimoyama, Yasuyuki; Kakizaki, Satoru; Kawamura, Osamu; Kusano, Motoyasu; Yamada, Masanobu

    2015-01-01

    Polyethylene glycol- (PEG-) based bowel preparations for colonoscopies are often poorly tolerated due to the large volumes of fluid intake required. We compared low-volume “modified” PEG + ascorbic acid (AJG522) with standard PEG with electrolytes (PEG + E) in addition to a stimulant laxative and an agent to improve bowel function for the bowel cleansing before colonoscopy to evaluate its efficacy, safety, and acceptability. Outpatients scheduled to undergo colonoscopy were randomized to receive either AJG522 or PEG + E. Bowel cleansing conditions were assessed via macroscopic fecal findings by blinded and independent investigators. A survey of the patients' feedback regarding the preparation was conducted by questionnaire. Successful cleansing was achieved in all cases, except for 4 cases in the PEG + E group, at 3 hours after taking the preparation. The fecal properties were significantly clearer in the AJG522 group than in the PEG + E group at 2 hours after taking each preparation (P = 0.013). Although the total liquid volume of the bowel preparation was not reduced, the AJG522 preparation could significantly reduce the required volume of the preparation (P < 0.0001). Moreover, the patients in the AJG522 group had better acceptability (P = 0.010). There were no significant differences in the safety profiles between groups (UMIN000013892). PMID:25688357

  2. Randomized controlled trial of 3 days fasting and oral senna, combined with mannitol and simethicone, before capsule endoscopy

    PubMed Central

    Chen, Hong-bin; Lian-xiang, Peng; Yue, Huang; Chun, Huang; Shu-ping, Xiao; Rong-pang, Lin; Xiao-zong, Wang; Xiao-lin, Li

    2017-01-01

    Abstract Background and Study Aims: The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. Patients and Methods: One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Results: Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ2 = 22.470, P = .000; χ2 = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ2 = 12.390, P = .000, χ2 = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ2 = 0.678, P = .509). Conclusions: Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine. PMID:29069003

  3. Development of CAD prototype system for Crohn's disease

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Kitasaka, Takayuki; Furukawa, Kazuhiro; Watanabe, Osamu; Ando, Takafumi; Goto, Hidemi; Mori, Kensaku

    2010-03-01

    The purpose of this paper is to present a CAD prototype system for Crohn's disease. Crohn's disease causes inflammation or ulcers of the gastrointestinal tract. The number of patients of Crohn's disease is increasing in Japan. Symptoms of Crohn's disease include intestinal stenosis, longitudinal ulcers, and fistulae. Optical endoscope cannot pass through intestinal stenosis in some cases. We propose a new CAD system using abdominal fecal tagging CT images for efficient diagnosis of Crohn's disease. The system displays virtual unfolded (VU), virtual endoscopic, curved planar reconstruction, multi planar reconstruction, and outside views of both small and large intestines. To generate the VU views, we employ a small and large intestines extraction method followed by a simple electronic cleansing method. The intestine extraction is based on the region growing process, which uses a characteristic that tagged fluid neighbor air in the intestine. The electronic cleansing enables observation of intestinal wall under tagged fluid. We change the height of the VU views according to the perimeter of the intestine. In addition, we developed a method to enhance the longitudinal ulcer on views of the system. We enhance concave parts on the intestinal wall, which are caused by the longitudinal ulcer, based on local intensity structure analysis. We examined the small and the large intestines of eleven CT images by the proposed system. The VU views enabled efficient observation of the intestinal wall. The height change of the VU views helps finding intestinal stenosis on the VU views. The concave region enhancement made longitudinal ulcers clear on the views.

  4. A randomized, blinded, prospective trial to compare the safety and efficacy of three bowel-cleansing solutions for colonoscopy (HSG-01*).

    PubMed

    Ell, C; Fischbach, W; Keller, R; Dehe, M; Mayer, G; Schneider, B; Albrecht, U; Schuette, W

    2003-04-01

    There are conflicting data regarding the optimal bowel preparation for colonoscopy. This study was carried out to compare the efficacy, safety, and tolerability of three widely used bowel lavage solutions: the standard polyethylene glycol-electrolyte solution based on the GoLytely formulation (PEG-EL1; Klean-Prep); a sulphate-free PEG-EL solution based on the NuLytely formulation (PEG-EL2, Endofalk); and a sodium phosphate preparation (NaP, Fleet Phospho-Soda). A total of 185 consecutive patients scheduled for elective colonoscopy were prospectively randomly assigned to undergo pre-colonoscopic bowel cleansing with either 4 l of PEG-EL1 (n=64), 3 l of PEG-EL2 (n=59), or 90 ml of NaP (n=62). The quality of preparatory colonic cleansing for each segment from the rectum to the ascending colon was scored on a five-level rating scale (1, very good to 5, very poor) by endoscopists who were blinded with regard to the type of preparation used. The primary outcome measure for the comparison of treatments was the "worst" score in any of the rated bowel segments. Safety and tolerability were evaluated by means of a symptom questionnaire completed by each patient immediately before the procedure. Of the 185 patients who were randomly assigned to one of the three treatments, 175 underwent colonoscopy and 173 were evaluable with regard to efficacy - 59, 54, and 60 patients treated with PEG-EL1, PEG-EL2, and NaP, respectively. The treatment groups were comparable with regard to the baseline characteristics. PEG-EL1 was statistically significantly superior to the other treatments in relation to the "worst cleansing" score ( P

  5. Design of a unit to produce hot distilled water for the same power consumption as a water heater

    NASA Technical Reports Server (NTRS)

    Bambenek, R. A.; Nuccio, P. P.

    1973-01-01

    Unit recovers 97% of water contained in pretreated waste water. Some factors are: cleansing agent prevents fouling of heat transfer surface by highly concentrated waste; absence of dynamic seals reduces required purge gas flow rate; and recycle loop maintains constant flushing process to carry cleansing agent across evaporation surface.

  6. Transportation Secure Data Center | NREL

    Science.gov Websites

    Data Center The Transportation Secure Data Center (TSDC) provides free access to detailed transportation data from a variety of travel surveys and studies. Data include global positioning system (GPS demographics. Learn more about the TSDC. Cleansed Data by State and Region Use the map to access cleansed data

  7. Randomised clinical trial: low-volume bowel preparation for colonoscopy - a comparison between two different PEG-based formulations.

    PubMed

    Repici, A; Cestari, R; Annese, V; Biscaglia, G; Vitetta, E; Minelli, L; Trallori, G; Orselli, S; Andriulli, A; Hassan, C

    2012-10-01

    Low-volume bowel preparations with polyethylene glycol (PEG) have been shown to provide an equivalent cleansing with improved tolerability as compared with standard PEG bowel preparation for colonoscopy. A new iso-osmotic sulphate-free formulation of PEG-Citrate-Simethicone (PEG-CS) in combination with bisacodyl has been recently developed. To compare the quality of bowel cleansing with PEG-CS with bisacodyl vs. PEG-Ascorbate (PEG-ASC) in adult out-patients undergoing colonoscopy. Randomised, observer-blind, parallel group study in adult out-patients undergoing colonoscopy in five Italian centres. Both preparations were taken the evening before the procedure. Subjects were instructed to take 2-4 tablets of 5 mg bisacodyl at 16:00 hours and 2 L of PEG-CS at 20:00 hours or 2 L of PEG-ASC plus 1 L of additional water the day before colonoscopy. Bowel cleansing was evaluated according to the Boston Bowel Preparation Scale (≥6 scores were considered as 'clinical success'), and mucosal visibility according to a 3-point scale. Tolerability, acceptability and compliance were also evaluated. Four hundred and eight patients were randomly allocated to PEG-CS and bisacodyl (n = 204, male patient 48%, mean age 59.1 years) or PEG-ASC (n = 204, male patient 51%, age 59.4 years). In the planned per-protocol analysis, the rate of successful preparation was 79.1% following PEG-CS with bisacodyl, and 70% following PEG-ASC (P < 0.05). Mucosal visibility was evaluated as optimal in 56.1% in the PEG-CS and bisacodyl and 46.3% in the PEG-ASC group (P < 0.05). There were no serious adverse events (AE) in each of the two experimental groups. Two subjects in the PEG-ASC group discontinued the study because of AE. Polyethylene glycol-Citrate-Simethicone in combination with bisacodyl was more effective for bowel cleansing than PEG-ASC for out-patient colonoscopy. Tolerability, safety, acceptability and compliance of the two low-volume bowel preparations were similar. © 2012 Blackwell Publishing Ltd.

  8. Developing New Methods for Microsampling and Sm/Nd Dating of Zoned Garnet

    NASA Astrophysics Data System (ADS)

    Pollington, A. D.; Baxter, E. F.

    2007-12-01

    Garnets provide one of the Earth Science community's most useful tools for studying rates, duration and timing of crustal processes. In this study we describe new techniques for fine sampling of multiple growth zones of garnet and Sm/Nd dating of each individual zone. We test these techniques on large (>5cm) garnets from a shear zone in the Tauern Window of Austria where we seek to quantify the growth history of garnet in a manner similar to dating tree rings. Microsampling permits a more precise quantification of duration, episodicity and kinetics of metamorphic reactions. Past studies of garnet growth duration - based on core and rim garnet ages - have been limited by sampling methods for extracting discrete, and accurate, growth zones. Modeling of radial growth symmetry in garnet shows that previous studies may underestimate garnet growth duration by as much as 50%. We are able to dramatically improve microsampling by using microdrilling guided by chemical maps of the garnet composition. This provides much improved precision and accuracy in sampling. By using chemical mapping of the garnet we can be sure that we are correctly sampling narrow (~500 micron wide) growth (i.e. age) zones rather than smearing and averaging multiple growth zones together. In principle, tens of growth zones (and ages) spanning the entire interval of garnet growth may be sampled and resolved. Microdrilled domains, the results of which are an ultrafine powder, are drilled and collected in water. Due to the adverse geochronological effect of unavoidable micro-inclusions in garnet, we have tested several partial dissolution techniques to cleanse the garnet of inclusions and yield higher 147Sm/144Nd and hence, more precise ages. Analysis of a finely crushed bulk Tauern Window garnet sample after HF/HClO3 cleansing indicates that 147Sm/144Nd at least as high as 0.89 is attainable in this particular sample, but cleansing efforts on microdrilled powders have thus far failed to yield such high ratios suggesting that the powders respond in unexpectedly different ways to our standard garnet cleansing procedures. Preliminary Sm/Nd age analysis of bulk garnet confirms a ~25Ma age for garnet growth. Progress in our inclusion cleansing procedures on microdrilled powders will be reported.

  9. Colon cleansing protocol in children: research conditions vs. clinical practice.

    PubMed

    Elitsur, Yoram; Balfaqih, Yaslam; Preston, Deborah

    2018-04-01

     Colon preparation rates are the limiting factor for a successful diagnostic colonoscopy in children. Different colon cleansing protocols have been published for use in children. Unfortunately, the applicability of those published research protocols has not been formally evaluated in routine clinical practice. We investigated the success rate of our previously published colon cleansing protocol as utilized in our clinical practice.  This was a retrospective study. In the clinical practice, the colon cleansing protocol included PEG-3350 at a dose of 2 g/kg/day plus Dulcolax (Bisacodyl, Boehringer Ingelheim, TX USA) 5 mg/day for 2 days. Adequate colon preparation was graded between 1 - 5, as previously described, and grade ≥ 4.0 was considered an adequate preparation. Patients were instructed to complete a questionnaire that included PEG-3350 dose, number of stools per day, consistency of each stool, and side effects (vomiting, abdominal pain). Clinical and endoscopic results were compared between the protocol under research conditions and routine practice.  The success rate of the colon preparation in our clinical practice was similar to the results observed under our research protocol (75 % vs. 73.6 %). Moreover, the total number of stools, stool consistency, and the intubation rate of the terminal ileum were also similar. We concluded, that in our experience, the colon cleansing protocol used under research conditions was effective and appropriate for use in routine clinical practice.  We recommend testing each new protocol under the routine conditions of clinical practice to confirm its applicability for general practitioners.

  10. Modelling lake-water photochemistry: three-decade assessment of the steady-state concentration of photoreactive transients (·OH, CO3(-·) and (3)CDOM(∗)) in the surface water of polymictic Lake Peipsi (Estonia/Russia).

    PubMed

    Minella, Marco; De Laurentiis, Elisa; Buhvestova, Olga; Haldna, Marina; Kangur, Külli; Maurino, Valter; Minero, Claudio; Vione, Davide

    2013-03-01

    Over the last 3-4 decades, Lake Peipsi water (sampling site A, middle part of the lake, and site B, northern part) has experienced a statistically significant increase of bicarbonate, pH, chemical oxygen demand, nitrate (and nitrite in site B), due to combination of climate change and eutrophication. By photochemical modelling, we predicted a statistically significant decrease of radicals ·OH and CO3(-·) (site A, by 45% and 35%, respectively) and an increase of triplet states of chromophoric dissolved organic matter ((3)CDOM(∗); site B, by ∼25%). These species are involved in pollutant degradation, but formation of harmful by-products is more likely with (3)CDOM(∗) than with ·OH. Therefore, the photochemical self-cleansing ability of Lake Peipsi probably decreased with time, due to combined effects of climate change and eutrophication. In different environments (e.g. Lake Maggiore, NW Italy), ecosystem restoration policies had the additional advantage of enhancing sunlight-driven detoxification, suggesting that photochemical self-cleansing would be positively correlated with lake water quality. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. 21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Detergent substances, other than soap, intended... Ingredients § 701.20 Detergent substances, other than soap, intended for use in cleansing the body. (a) In its definition of the term cosmetic, the Federal Food, Drug, and Cosmetic Act specifically excludes soap. The...

  12. 21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Detergent substances, other than soap, intended... Ingredients § 701.20 Detergent substances, other than soap, intended for use in cleansing the body. (a) In its definition of the term cosmetic, the Federal Food, Drug, and Cosmetic Act specifically excludes soap. The...

  13. 21 CFR 701.20 - Detergent substances, other than soap, intended for use in cleansing the body.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Detergent substances, other than soap, intended... Ingredients § 701.20 Detergent substances, other than soap, intended for use in cleansing the body. (a) In its definition of the term cosmetic, the Federal Food, Drug, and Cosmetic Act specifically excludes soap. The...

  14. Why Does the “Sinner” Act Prosocially? The Mediating Role of Guilt and the Moderating Role of Moral Identity in Motivating Moral Cleansing

    PubMed Central

    Ding, Wan; Xie, Ruibo; Sun, Binghai; Li, Weijian; Wang, Duo; Zhen, Rui

    2016-01-01

    Numerous studies have found that people tend to commit prosocial acts subsequent to previous immoral acts, as a response to the latter. This phenomenon is called moral cleansing or moral compensation. However, the specific mechanism how previous immoral acts motivate moral compensatory behaviors is still not fully understood. This study aimed to examine the roles of guilt and moral identity in the relation between previous immoral acts and subsequent prosocial behaviors to clarify the mechanism. Based on the extant research, the current study proposed a moderated mediation model to illustrate the process of moral cleansing. Specifically, a previous immoral act motivates guilt, which further leads to subsequent prosocial behaviors, while moral identity facilitates this process. The participants were primed by a recalling task (immoral act vs. a neutral event). The results support the hypothesized model and provide a framework that explains moral cleansing by integrating the roles of guilt and moral identity. These findings highlight the dynamic nature of people’s morality with regard to how people adapt moral behaviors to protect their moral self-image. PMID:27660617

  15. Behavior of pathogenic bacteria in the oyster, Crassostrea commercialis, during depuration, re-laying, and storage.

    PubMed Central

    Son, N T; Fleet, G H

    1980-01-01

    Oysters (Crassostrea commercials) harvested from major cultivation areas within the state of New South Wales, Australia, were commonly contaminated with low levels of the food-poisoning organisms Bacillus cereus, Clostridium perfringens, and Vibrio parahaemolyticus. Salmonella was found in oysters on only one occasion. These bacteria were cleansed from oysters during oyster purification by re-laying in a non-polluted waterway. Oysters were laboratory contaminated to levels in excess 1,000 cells per g with either B. cereus, C. perfringens, V. parahaemolyticus, Salmonella typhimurium, or S. senftenberg. These species were cleansed from such oysters during purification in a laboratory depuration unit that used ultraviolet light for sterilizing the depuration water. Escherichia coli was also cleansed from oysters under the same re-laying or depuration conditions so that its measurement alone could be used to indicate the cleansing of the above pathogenic species. The levels of these bacteria were also measured during the storage of oysters under conditions that occur during marketing. While B. cereus counts remained relatively stable during storage, the Salmonella spp. gradually decreased in numbers and C. perfringens rapidly died off. V. parahaemolyticus counts increased slightly during the first 4 days of storage, after which decreases occurred. PMID:6257164

  16. Behavior of pathogenic bacteria in the oyster, Crassostrea commercialis, during depuration, re-laying, and storage.

    PubMed

    Son, N T; Fleet, G H

    1980-12-01

    Oysters (Crassostrea commercials) harvested from major cultivation areas within the state of New South Wales, Australia, were commonly contaminated with low levels of the food-poisoning organisms Bacillus cereus, Clostridium perfringens, and Vibrio parahaemolyticus. Salmonella was found in oysters on only one occasion. These bacteria were cleansed from oysters during oyster purification by re-laying in a non-polluted waterway. Oysters were laboratory contaminated to levels in excess 1,000 cells per g with either B. cereus, C. perfringens, V. parahaemolyticus, Salmonella typhimurium, or S. senftenberg. These species were cleansed from such oysters during purification in a laboratory depuration unit that used ultraviolet light for sterilizing the depuration water. Escherichia coli was also cleansed from oysters under the same re-laying or depuration conditions so that its measurement alone could be used to indicate the cleansing of the above pathogenic species. The levels of these bacteria were also measured during the storage of oysters under conditions that occur during marketing. While B. cereus counts remained relatively stable during storage, the Salmonella spp. gradually decreased in numbers and C. perfringens rapidly died off. V. parahaemolyticus counts increased slightly during the first 4 days of storage, after which decreases occurred.

  17. A new fractional order derivative based active contour model for colon wall segmentation

    NASA Astrophysics Data System (ADS)

    Chen, Bo; Li, Lihong C.; Wang, Huafeng; Wei, Xinzhou; Huang, Shan; Chen, Wensheng; Liang, Zhengrong

    2018-02-01

    Segmentation of colon wall plays an important role in advancing computed tomographic colonography (CTC) toward a screening modality. Due to the low contrast of CT attenuation around colon wall, accurate segmentation of the boundary of both inner and outer wall is very challenging. In this paper, based on the geodesic active contour model, we develop a new model for colon wall segmentation. First, tagged materials in CTC images were automatically removed via a partial volume (PV) based electronic colon cleansing (ECC) strategy. We then present a new fractional order derivative based active contour model to segment the volumetric colon wall from the cleansed CTC images. In this model, the regionbased Chan-Vese model is incorporated as an energy term to the whole model so that not only edge/gradient information but also region/volume information is taken into account in the segmentation process. Furthermore, a fractional order differentiation derivative energy term is also developed in the new model to preserve the low frequency information and improve the noise immunity of the new segmentation model. The proposed colon wall segmentation approach was validated on 16 patient CTC scans. Experimental results indicate that the present scheme is very promising towards automatically segmenting colon wall, thus facilitating computer aided detection of initial colonic polyp candidates via CTC.

  18. Prerequisites of Colonoscopy

    PubMed Central

    Hong, Kyong Hee

    2014-01-01

    Colonoscopy is a widely accepted method for the evaluation of the colon and terminal ileum. Its diagnostic accuracy and therapeutic safety are influenced by prerequisites, including modulation of medication and bowel cleansing. Appropriate choices of sedative medication and bowel-cleansing regimen, together with diet modification, should be made based on the patient's underlying disease, age, and medication intake. Moreover, effective methods for patient education regarding bowel preparation should be considered. PMID:25133119

  19. The use of chlorhexidine to reduce maternal and neonatal mortality and morbidity in low-resource settings

    PubMed Central

    McClure, Elizabeth M; Goldenberg, Robert L; Brandes, Neal; Darmstadt, Gary L; Wright, Linda L

    2009-01-01

    Of the 4 million neonatal deaths and 500,000 maternal deaths that occur annually worldwide, almost 99% are in developing countries and one-third are associated with infections. Implementation of proven interventions and targeted research on a select number of promising high-impact preventative and curative interventions are essential to achieve Millennium Development Goals for reduction of child and maternal mortality. Feasible, simple, low-cost interventions have the potential to significantly reduce the mortality and severe morbidity associated with infection in these settings. Studies of chlorhexidine in developing countries have focused on three primary uses: 1) intrapartum vaginal and neonatal wiping, 2) neonatal wiping alone, and 3) umbilical cord cleansing. A study of vaginal wiping and neonatal skin cleansing with chlorhexidine, conducted in Malawi in the 1990s suggested that chlorhexidine has potential to reduce neonatal infectious morbidity and mortality. A recent trial of cord cleansing conducted in Nepal also demonstrated benefit. Although studies have shown promise, widespread acceptance and implementation of chlorhexidine use has not yet occurred. This paper is derived in part from data presented at a conference on the use of chlorhexidine in developing countries and reviews the available evidence related to chlorhexidine use to reduce mortality and severe morbidity due to infections in mothers and neonates in low-resource settings. It also summarizes issues related to programmatic implementation. PMID:17399714

  20. Adjuncts to colonic cleansing before colonoscopy.

    PubMed

    Park, Sanghoon; Lim, Yun Jeong

    2014-03-21

    Pre-procedural cleansing of the bowel can maximize the effectiveness and efficiency of colonoscopy. Yet, efficacy of the current gold standard colonic preparation method - high-volume oral administration of purgative agents 12-24 h prior to the procedure - is limited by several factors, such as patient compliance (due to poor palatability and inconvenience of the dosing regimen) and risks of complications (due to drug interactions or intolerance). Attempts to resolve these limitations have included providing adjunctive agents and methods to promote the colonic cleansing ability of the principal purgative agent, with the aim of lessening unpleasant side effects (such as bloating) and reducing the large ingested volume requirement. Several promising adjunctive agents are bisacodyl, magnesium citrate, senna, simethicone, metoclopramide, and prokinetics, and each are being investigated for their potential. This review provides an up to date summary of the reported investigations into the potencies and weaknesses of the key adjuncts currently being applied in clinic as supplements to the traditional bowel preparation agents. While the comparative analysis of these adjuncts showed that no single agent or method has yet achieved the goal of completely overcoming the limitations of the current gold standard preparation method, they at least provide endoscopists with an array of alternatives to help improve the suboptimal efficacy of the main cleansing solutions when used alone. To aid in this clinical endeavor, a subjective grade was assigned to each adjunct to indicate its practical value. In addition, the systematic review of the currently available agents and methods provides insight into the features of each that may be overcome or exploited to create novel drugs and strategies that may become adopted as effective bowel cleansing adjuncts or alternatives.

  1. Adjuncts to colonic cleansing before colonoscopy

    PubMed Central

    Park, Sanghoon; Lim, Yun Jeong

    2014-01-01

    Pre-procedural cleansing of the bowel can maximize the effectiveness and efficiency of colonoscopy. Yet, efficacy of the current gold standard colonic preparation method - high-volume oral administration of purgative agents 12-24 h prior to the procedure - is limited by several factors, such as patient compliance (due to poor palatability and inconvenience of the dosing regimen) and risks of complications (due to drug interactions or intolerance). Attempts to resolve these limitations have included providing adjunctive agents and methods to promote the colonic cleansing ability of the principal purgative agent, with the aim of lessening unpleasant side effects (such as bloating) and reducing the large ingested volume requirement. Several promising adjunctive agents are bisacodyl, magnesium citrate, senna, simethicone, metoclopramide, and prokinetics, and each are being investigated for their potential. This review provides an up to date summary of the reported investigations into the potencies and weaknesses of the key adjuncts currently being applied in clinic as supplements to the traditional bowel preparation agents. While the comparative analysis of these adjuncts showed that no single agent or method has yet achieved the goal of completely overcoming the limitations of the current gold standard preparation method, they at least provide endoscopists with an array of alternatives to help improve the suboptimal efficacy of the main cleansing solutions when used alone. To aid in this clinical endeavor, a subjective grade was assigned to each adjunct to indicate its practical value. In addition, the systematic review of the currently available agents and methods provides insight into the features of each that may be overcome or exploited to create novel drugs and strategies that may become adopted as effective bowel cleansing adjuncts or alternatives. PMID:24659864

  2. Polyethylene glycol plus simethicone in small-bowel preparation for capsule endoscopy.

    PubMed

    Spada, Cristiano; Riccioni, Maria E; Familiari, Pietro; Spera, Gianluca; Pirozzi, Giuseppe A; Marchese, Michele; Bizzotto, Alessandra; Ingrosso, Marcello; Costamagna, Guido

    2010-05-01

    Small-bowel contents can hamper the quality of video-capsule endoscopy (VCE). No standardized protocol has been proposed and overnight fasting remains the proposed preparation for VCE. The aim was to evaluate the effects of 2 regimens of bowel preparation on small intestine cleansing, diagnostic yield and capsule transit times. This is a prospective, randomized, blinded, and controlled study. Sixty patients referred for VCE were randomized into 2 groups. Group A ingested 2l of a polyethylene glycol and simethicone solution 16h before VCE. Group B were instructed to consume a fibre-free diet and allowed to consume clear liquids the day before VCE. The small-bowel cleansing was graded as "complete" if the entire wall was assessable, "incomplete" if more than 50% of the wall was visible, and "insufficient" if less than 50% of the wall was visible. In group A, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 42%, 39% and 19% of cases respectively. In group B, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 43%, 33% and 24% of cases respectively. No significant differences were observed between the two groups, regarding small-bowel cleansing level (p=0.65). No differences were also observed in the diagnostic yield (48.2%, 13.8% and 38% vs 65.5%, 6.9% and 27.6% of positive, suspicious and no findings respectively, in groups A and B [p=0.39]) and small-bowel transit times (mean 288min and 299 min in groups A and B respectively [p=0.70]). The results of the present study do not support the use of 2l of a polyethylene glycol and simethicone solution before VCE. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. 21 CFR 200.50 - Ophthalmic preparations and dispensers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... intended for ophthalmic use, including preparations for cleansing the eyes, should be sterile. It is... use in the eye. (2) The Food and Drug Administration concludes that all such preparations, if they are... applicable to ophthalmic preparations that are regulated as medical devices. (3) The containers of ophthalmic...

  4. Explanations for Child Sexual Abuse Given by Convicted Offenders in Malawi: No Evidence for "HIV Cleansing"

    ERIC Educational Resources Information Center

    Mtibo, Charles; Kennedy, Neil; Umar, Eric

    2011-01-01

    Objective: A commonly cited, but unproven reason given for the rise in reported cases of child sexual abuse in Sub-Saharan Africa is the "HIV cleansing myth"--the belief that an HIV infected individual can be cured by having sex with a child virgin. The purpose of this study was to explore in Malawi the reasons given by convicted sex…

  5. In vivo cleansing efficacy of biodegradable exfoliating beads assessed by skin bioengineering techniques.

    PubMed

    Kitsongsermthon, J; Duangweang, K; Kreepoke, J; Tansirikongkol, A

    2017-11-01

    The plastic microbeads, used in many cleansers, will be banned in cosmetic and personal care products within 2017 since they are non-degradable and can disturb the living organisms in water reservoirs. Various choices of biodegradable beads are commercially available, but their efficacy has not been proven yet. This study aimed to compare the cleansing efficacy in dirt and sebum removal aspects of three types of exfoliating beads. The gel scrubs with polyethylene (PE) beads, mannan beads or wax beads, were formulated and evaluated for their stability. The in vivo evaluation was done in 38 healthy volunteers and the skin irritation, efficacy for dirt and sebum removal were measured by Mexameter ® , Colorimeter ® , and Sebumeter ® , respectively. The selected gel scrubs did not cause an irritation in any volunteers. The differences in dirt residues between before and after scrubbing were not statistically significant among three gel scrubs and the similar result was also reported in the sebum removal study. All gel scrubs demonstrated the comparable cleansing efficacy in term of dirt and sebum removal. Thus, mannan beads and wax beads may be replaced non-biodegradable PE beads to achieve the similar cleansing effect. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Lubiprostone plus PEG electrolytes versus placebo plus PEG electrolytes for outpatient colonoscopy preparation: a randomized, double-blind placebo-controlled trial.

    PubMed

    Sofi, Aijaz A; Nawras, Ali T; Pai, Chetan; Samuels, Qiana; Silverman, Ann L

    2015-01-01

    Bowel preparation using large volume of polyethylene glycol (PEG) solutions is often poorly tolerated. Therefore, there are ongoing efforts to develop an alternative bowel cleansing regimen that should be equally effective and better tolerated. The aim of this study was to assess the efficacy of lubiprostone (versus placebo) plus PEG as a bowel cleansing preparation for colonoscopy. Our study was a randomized, double-blind placebo-controlled design. Patients scheduled for screening colonoscopy were randomized 1:1 to lubiprostone (group 1) or placebo (group 2) plus 1 gallon of PEG. The primary endpoints were patient's tolerability and endoscopist's evaluation of the preparation quality. The secondary endpoint was to determine any reduction in the amount of PEG consumed in the lubiprostone group compared with the placebo group. One hundred twenty-three patients completed the study and were included in the analysis. There was no difference in overall cleanliness. The volume of PEG was similar in both the groups. The volume of PEG approached significance as a predictor of improved score for both the groups (P = 0.054). Lubiprostone plus PEG was similar to placebo plus PEG in colon cleansing and volume of PEG consumed. The volume of PEG consumed showed a trend toward improving the quality of the colon cleansing.

  7. Cleansing technique using high-velocity steam-air micromist jet spray.

    PubMed

    Fukuda, Koichi; Ishihara, Masayuki; Murakami, Kaoru; Nakamura, Shingo; Sato, Yoko; Kuwabara, Masahiro; Fujita, Masanori; Kiyosawa, Tomoharu; Yokoe, Hidetaka

    2017-10-01

    Application of a high-velocity steam-air micromist jet spray (HVS-AMJS; micromist average diameter: 2.4 μm) for cleansing the skin is proposed. Low-pressure steam is mixed with compressed air (pH 6.5) in a nozzle, and then sprayed at a pressure of ≦0.25 MPa and a velocity of ≧0.34 m/s on the skin or surface of material located approximately 5-10 cm from the nozzle. The temperature on the sprayed surface and water flow rate could be controlled between 42 °C and 46 °C and at approximately 50 mL/min, respectively. Compared with ultrasonic cleansing with tap water and rubbing with only tap water, the HVS-AMJS successfully removed fluorescent lotion covering pieces of wood and significantly reduced both the number of coliforms and the total viable counts on pieces of wood and gauze. Furthermore, the HVS-AMJS effectively removed oily ink from the skin of hairless rats, and temporarily elevated the skin temperature and blood flow, indicating massage effects. The striking characteristics of this cleansing technique using HVS-AMJS are not only its ability to remove microbes and residue without using any chemicals or detergents but also its massage effects.

  8. Self-expanding metallic stents drainage for acute proximal colon obstruction

    PubMed Central

    Yao, Li-Qin; Zhong, Yun-Shi; Xu, Mei-Dong; Xu, Jian-Min; Zhou, Ping-Hong; Cai, Xian-Li

    2011-01-01

    AIM: To clarify the usefulness of the self-expanding metallic stents (SEMS) in the management of acute proximal colon obstruction due to colon carcinoma before curative surgery. METHODS: Eighty-one colon (proximal to spleen flex) carcinoma patients (47 males and 34 females, aged 18-94 years, mean = 66.2 years) treated between September 2004 and June 2010 for acute colon obstruction were enrolled to this study, and their clinical and radiological features were reviewed. After a cleaning enema was administered, urgent colonoscopy was performed. Subsequently, endoscopic decompression using SEMS placement was attempted. RESULTS: Endoscopic decompression using SEMS placement was technically successful in 78 (96.3%) of 81 patients. Three patients’ symptoms could not be relieved after SEMS placement and emergent operation was performed 1 d later. The site of obstruction was transverse colon in 18 patients, the hepatic flex in 42, and the ascending colon in 21. Following adequate cleansing of the colon, patients’ abdominal girth was decreased from 88 ± 3 cm before drainage to 72 ± 6 cm 7 d later, and one-stage surgery after 8 ± 1 d (range, 7-10 d) was performed. No anastomotic leakage or postoperative stenosis occurred after operation. CONCLUSION: SEMS placement is effective and safe in the management of acute proximal colon obstruction due to colon carcinoma, and is considered as a bridged method before curative surgery. PMID:21876623

  9. Perforation and mortality after cleansing enema for acute constipation are not rare but are preventable.

    PubMed

    Niv, Galia; Grinberg, Tamar; Dickman, Ram; Wasserberg, Nir; Niv, Yaron

    2013-01-01

    Constipation is a common complaint, frequently treated with cleansing enema. Enemas can be very effective but may cause serious adverse events, such as perforation or metabolic derangement. Our aim was to evaluate the outcome of the use of cleansing enema for acute constipation and to assess adverse events within 30 days of therapy. We performed a two-phase study: an initial retrospective and descriptive study in 2010, followed by a prospective study after intervention, in 2011. According to the results of the first phase we established guidelines for the treatment of constipation in the Emergency Department and then used these in the second phase. There were 269 and 286 cases of severe constipation in the first and second periods of the study, respectively. In the first study period, only Fleet® Enema was used, and in the second, this was changed to Easy Go enema (free of sodium phosphate). There was a 19.2% decrease in the total use of enema, in the second period of the study (P < 0.0001). Adverse events and especially, the perforation rate and the 30-day mortality in patients with constipation decreased significantly in the second phase: 3 (1.4%) versus 0 (P = 0.0001) and 8 (3.9%) versus 2 (0.7%) (P = 0.0001), for perforation and death in the first and second period of the study, respectively. Enema for the treatment of acute constipation is not without adverse events, especially in the elderly, and should be applied carefully. Perforation, hyperphosphatemia (after Fleet Enema), and sepsis may cause death in up to 4% of cases. Guidelines for the treatment of acute constipation and for enema administration are urgently needed.

  10. Perforation and mortality after cleansing enema for acute constipation are not rare but are preventable

    PubMed Central

    Niv, Galia; Grinberg, Tamar; Dickman, Ram; Wasserberg, Nir; Niv, Yaron

    2013-01-01

    Objectives Constipation is a common complaint, frequently treated with cleansing enema. Enemas can be very effective but may cause serious adverse events, such as perforation or metabolic derangement. Our aim was to evaluate the outcome of the use of cleansing enema for acute constipation and to assess adverse events within 30 days of therapy. Methods We performed a two-phase study: an initial retrospective and descriptive study in 2010, followed by a prospective study after intervention, in 2011. According to the results of the first phase we established guidelines for the treatment of constipation in the Emergency Department and then used these in the second phase. Results There were 269 and 286 cases of severe constipation in the first and second periods of the study, respectively. In the first study period, only Fleet® Enema was used, and in the second, this was changed to Easy Go enema (free of sodium phosphate). There was a 19.2% decrease in the total use of enema, in the second period of the study (P < 0.0001). Adverse events and especially, the perforation rate and the 30-day mortality in patients with constipation decreased significantly in the second phase: 3 (1.4%) versus 0 (P = 0.0001) and 8 (3.9%) versus 2 (0.7%) (P = 0.0001), for perforation and death in the first and second period of the study, respectively. Conclusion Enema for the treatment of acute constipation is not without adverse events, especially in the elderly, and should be applied carefully. Perforation, hyperphosphatemia (after Fleet Enema), and sepsis may cause death in up to 4% of cases. Guidelines for the treatment of acute constipation and for enema administration are urgently needed. PMID:23658492

  11. Actinide-contaminated Skin: Comparing Decontamination Efficacy of Water, Cleansing Gels, and DTPA Gels.

    PubMed

    Tazrart, A; Bolzinger, M A; Lamart, S; Coudert, S; Angulo, J F; Jandard, V; Briançon, S; Griffiths, N M

    2018-07-01

    Skin contamination by alpha-emitting actinides is a risk to workers during nuclear fuel production and reactor decommissioning. Also, the list of items for potential use in radiological dispersal devices includes plutonium and americium. The actinide chemical form is important and solvents such as tributyl phosphate, used to extract plutonium, can influence plutonium behavior. This study investigated skin fixation and efficacy of decontamination products for these actinide forms using viable pig skin in the Franz cell diffusion system. Commonly used or recommended decontamination products such as water, cleansing gel, diethylenetriamine pentaacetic acid, or octadentate hydroxypyridinone compound 3,4,3-LI(1,2-HOPO), as well as diethylenetriamine pentaacetic acid hydrogel formulations, were tested after a 2-h contact time with the contaminant. Analysis of skin samples demonstrated that more plutonium nitrate is bound to skin as compared to plutonium-tributyl phosphate, and fixation of americium to skin was also significant. The data show that for plutonium-tributyl phosphate all the products are effective ranging from 80 to 90% removal of this contaminant. This may be associated with damage to the skin by this complex and suggests a mechanical/wash-out action rather than chelation. For removal of americium and plutonium, both Trait Rouge cleansing gel and diethylenetriamine pentaacetic acid are better than water, and diethylenetriamine pentaacetic acid hydrogel is better than Osmogel. The different treatments, however, did not significantly affect the activity in deeper skin layers, which suggests a need for further improvement of decontamination procedures. The new diethylenetriamine pentaacetic acid hydrogel preparation was effective in removing americium, plutonium, and plutonium-tributyl phosphate from skin; such a formulation offers advantages and thus merits further assessment.

  12. Water Purification Systems

    NASA Technical Reports Server (NTRS)

    1992-01-01

    A water purification/recycling system developed by Photo-Catalytics, Inc. (PCI) for NASA is commercially available. The system cleanses and recycles water, using a "photo-catalysis" process in which light or radiant energy sparks a chemical reaction. Chemically stable semiconductor powders are added to organically polluted water. The powder absorbs ultraviolet light, and pollutants are oxidized and converted to carbon dioxide. Potential markets for the system include research and pharmaceutical manufacturing applications, as well as microchip manufacture and wastewater cleansing.

  13. Hyper-hydration: a new perspective on wound cleansing, debridement and healing.

    PubMed

    2016-06-01

    In a recent symposium organised by Hartmann, the involvement of moisture and hydration in healing was re-evaluated and the use of hyper-hydration in promoting healing was examined. The distinction between hyperhydration and maceration was also discussed. Clinical studies were presented to give an overview of the clinical evidence to how Hydro-Responsive Wound Dressings can aid in healing via cleansing, debridement and desloughing of several wound types.

  14. Evaluation of a cleanser for petroleum-contaminated skin.

    PubMed

    Phieffer, Laura S; Banks, David M; Bosse, Michael J; Meyer, Martha H; Meyer, Ralph A; Smith, Kevin

    2003-12-01

    Extremity injuries contaminated with petroleum products pose clinical dilemmas. This project was designed to evaluate the efficacy of a dioctyl sulfosuccinate (DS) solution for cleansing petroleum-contaminated skin. One hundred Sprague-Dawley rats were subjected to a contamination protocol followed by a cleansing procedure. Four petroleum contaminants and five cleansing solutions were selected. The protocol consisted of shaving, initial punch biopsy, contamination, precleansing punch biopsy, standardized scrub protocol, and postcleansing punch biopsy. Biopsy samples were analyzed for petroleum residue using fluorometry. The 10% DS solution had the highest reduction of crude oil, grease, and tar: 99.6 +/- 0.4% (mean +/- SD) contaminant reduction for crude oil, 99.8 +/- 0.2% for grease, and 99.8 +/- 0.2% for tar. The other cleansers showed less efficacy (p < 0.05). Concentrated DS appears to be significantly more effective at cleaning petroleum products from skin than the commonly chosen surgical and commercial cleansers.

  15. Spacecraft utensil/hand cleansing fixture. [for space shuttles

    NASA Technical Reports Server (NTRS)

    Rosener, A. A.; Jonkoniec, T. G.; Wilson, D. A.; Schulz, J. R.

    1975-01-01

    A system concept for an inflight utensil/hand cleansing fixture is described which includes the following features: (1) capability for efficient cleansing and rinsing of utensils or hands, and (2) provision for general waste fluid disposal. The design concept provides for the capability of functioning for a 30 day shuttle mission containing seven occupants/users. The long range goal is to provide a functioning system capable of operating for missions of at least 120 days. The fixture is a self-contained unit that can be installed in the standard water interface requirements. Service to the unit is a single source of unheated potable water and water is discharged from the unit into a single return waste connection. In addition, the design includes provisions for the intake and discharge of purge air and the discharge of evolved gases. Both the air and the gases are filtered or processed in the assembly before releasing them into the habitability area.

  16. Depth Acuity Methodology for Electronic 3D Displays: eJames (eJ)

    DTIC Science & Technology

    2016-07-01

    AFRL-RH-WP-TR-2016-0060 Depth Acuity Methodology for Electronic 3D Displays: eJames (eJ) Eric L. Heft, John McIntire...AND SUBTITLE Depth Acuity Methodology for Electronic 3D Displays: eJames (eJ) 5a. CONTRACT NUMBER FA8650-08-D-6801-0050 5b. GRANT NUMBER...of 3D electronic displays: one active-eyewear Stereo 3D (S3D) and two non-eyewear full parallax Field-of-Light Display (FoLD) systems. The two FoLD

  17. Contamination of blood cultures during venepuncture: fact or myth?

    PubMed Central

    Shahar, E.; Wohl-Gottesman, B. S.; Shenkman, L.

    1990-01-01

    Contamination of blood cultures is believed to occur mainly during the venepuncture procedure. Consequently, meticulous preparation of the venepuncture site is widely recommended. To determine whether the contamination rate is indeed affected by the quality of the antiseptic procedure at the venepuncture site, 181 paired cultures were collected from 176 patients during a 6-month period after either strict antiseptic cleansing of skin with alcohol followed by povidone-iodine, or after brief disinfection with alcohol alone. The contamination rate was not influenced by the antiseptic procedure, and corresponded to the accepted percentage reported in most other studies. Eight false positive cultures (4.4%) were obtained after strict antisepsis of the skin and 6 (3.3%) after short simple cleansing with alcohol (P = 0.39). Our results suggest that contamination of blood cultures may not be related to the venepuncture procedure--regardless of the antiseptic technique used--but may be due to later stages of laboratory handling and processing of the specimens. Review of the literature has provided further indirect evidence to support this conclusion. PMID:2084653

  18. Confronting Resurgent Russia: U.S. Air Force Global Strike Contributions to National Deterrent Strategy

    DTIC Science & Technology

    2010-04-01

    options at his disposal to back up other efforts. The global strike capabilities outlined in this paper are not particularly palatable . They would...against Serbia as part of operation Allied Force. During the air war over the ethnic cleansing of Albanian Muslims in Kosovo, the coalition forces...convince the Serb leader, Slobodan Milosevic, to end the cleansing by his troops. The top Air Force leader in Europe believed that the lack of

  19. Resolving Kirkuk: Lessons Learned from Settlements of Earlier Ethno-Territorial Conflicts

    DTIC Science & Technology

    2012-01-01

    interests, the Federation feared that the loss of Brčko would be seen as rewarding Serb-inflicted ethnic cleansing . The status of Brčko was thus a...governance arrangements for Mostar began with institutionalization of the status quo, which reflected ethnic cleansing during the war. The starting point...both made significant commitments that made the GFA palatable to both Unionists and Republicans. In Brčko, the international supervisor was given

  20. [The myth of virgin cleansing: Latest news on an archaic magico-religious practice].

    PubMed

    Charlier, P; Bou Abdallah, F; Brun, L; Hoang-Oppermann, V; Deo, S; Mostefai-Dulac, Y; Mamzer, M-F; Hervé, C

    2018-03-01

    In the medical anthropology section of the Nanterre Hospital (France) for migrants and refugees, three cases were recorded of "virgin cleansing" in sub-Saharan African countries. These consisted of sexual assaults (2 instances of rape and 1 of sexual interference) on sexually immature females (young girls) by patients with sexually transmitted infections (mainly HIV, syphilis) hoping they might thereby be cured. These particularly atrocious hetero-aggressive sexual practices based on magical arguments are unfortunately universal and are not limited to a specific culture. At the medical anthropology level, the belief in cleansing by virgins is based on the notion that the patient is dirty and impure. In the same way that emetics and/or laxatives are prescribed in the case of intestinal disorders (to "eliminate" the disease), some subjects use diuretics for urinary abnormalities or, literally, "clean vaginas (or anuses)" to purge their own miasma. The rising tide of population migrations (some of whom carry chronic infections), refugee camps, prolonged incarcerations, etc., makes observations of such phenomena increasingly frequent. Belief in cleansing by virgins (and the fatal consequences thereof) will be difficult to eradicate. The education of populations and health professionals should promote absolute respect for the body of children, and, more generally, of others, particularly since at this time of increasingly marked migratory flows, this problem sadly risks becoming widespread. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Efficacy of prokinetics with a split-dose of polyethylene glycol in bowel preparation for morning colonoscopy: a randomized controlled trial.

    PubMed

    Kim, Hyoung Jun; Kim, Tae Oh; Shin, Bong Chul; Woo, Jae Gon; Seo, Eun Hee; Joo, Hee Rin; Heo, Nae-Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo; Shin, Jin-Yong; Lee, Nae Young

    2012-01-01

    Currently, a split-dose of polyethylene glycol (PEG) is the mainstay of bowel preparation due to its tolerability, bowel-cleansing action, and safety. However, bowel preparation with PEG is suboptimal because residual fluid reduces the polyp detection rate and requires a more thorough colon inspection. The aim of our study was to demonstrate the efficacy of a sufficient dose of prokinetics on bowel cleansing together with split-dose PEG. A prospective endoscopist-blinded study was conducted. Patients were randomly allocated to two groups: prokinetic with split-dose PEG or split-dose PEG alone. A prokinetic [100 mg itopride (Itomed)], was administered twice simultaneously with each split-dose of PEG. Bowel-cleansing efficacy was measured by endoscopists using the Ottawa scale and the segmental fluidity scale score. Each participant completed a bowel preparation survey. Mean scores from the Ottawa scale, segmental fluid scale, and rate of poor preparation were compared between both groups. Patients in the prokinetics with split-dose PEG group showed significantly lower total Ottawa and segmental fluid scores compared with patients in the split-dose of PEG alone group. A sufficient dose of prokinetics with a split-dose of PEG showed efficacy in bowel cleansing for morning colonoscopy, largely due to the reduction in colonic fluid. Copyright © 2012 S. Karger AG, Basel.

  2. Quality analysis, miceller behavior, and environmental impact of some laundry detergents available in Bangladesh.

    PubMed

    Nur-E-Alam, M; Islam, M Monirul; Islam, M Nazrul; Rima, Farhana Rahman; Islam, M Nurul

    2016-03-01

    The cleansing efficiencies of laundry detergents depend on composition and variation of ingredients such as surfactants, phosphate, and co-builders. Among these ingredients, surfactants and phosphate are considered as hazardous materials. Knowledge on compositions and micellar behavior is very useful for understanding their cleansing efficiencies and environmental impact. With this view, composition, critical micelle concentration, and dissolved oxygen level in aqueous solution of some laundry detergents available in Bangladesh such as keya, Wheel Power White, Tibet, Surf Excel, and Chaka were determined. Surfactant and phosphate were found to be maximum in Surf Excel and Wheel Power White, respectively, while both of the ingredients were found to be minimum in Tibet. The critical micelle concentration decreased with increasing surfactant content. The amount of laundry detergents required for efficient cleansing was found to be minimum for Surf Excel and maximum for Chaka; however, cleansing cost was the highest for Surf Excel and the lowest for Tibet. The maximum amount of surfactants and phosphate was discharged by Surf Excel and Wheel Power White, respectively, while discharges of both of the ingredients were minimum for Tibet. The maximum decrease of dissolved oxygen level was caused by Surf Excel and the minimum by Tibet. Therefore, it can be concluded that Tibet is cost-effective and environment friendly, whereas Surf Excel and Wheel Power White are expensive and pose a threat to water environment.

  3. Safety, effectiveness and comparability of professional skin cleansers.

    PubMed

    Terhaer, Flora K; Bock, Meike; Fartasch, Manigé; Gabard, Bernard; Elsner, Peter; Kleesz, Peter; Landeck, Lilla; Pohrt, Ute; Seyfarth, Florian; Schliemann, Sibylle; Diepgen, Thomas L; Zagrodnik, Fred; John, Swen Malte

    2010-10-01

    There are no widely-accepted methodical specifications with which to objectify cleansing effectiveness and skin compatibility of occuptional skin cleansing products in Europe. Therefore the German Social Insurance Agency (DGUV) initiated a study with the goal to evaluate such products in view of the potency and the safety of hand cleansers. A market analysis was a part of the project. The product descriptions and safety data sheets of 120 products (5-20/manufacturer) of 11 manufacturers were evaluated between 02/2008 and 04/2008. The manufacturers used mainly ingredients of low irritancy. The declaration of the applied ingredients was in the majority of the cases correctly labeled according to the INCI Declaration. Although there was documentation of skin tolerability for most products, the manufacturers used widely differing tests of skin compatibility. Evidences for cleansing effectiveness were not declared or have not been provided. One manufacturer even promised medical effects of its products. There was no uniform general classification of products making it difficult to identify characteristics of cleansers and choose between them. Presently, there are no commonly accepted criteria to classify products in view of cleansing effectiveness und skin compatibility. Generally accepted criteria and test methods are needed for the evaluation of hand cleansers in order to provide the possibility of transparency and comparability. © The Authors • Journal compilation © Blackwell Verlag GmbH, Berlin.

  4. Bowel cleansing before colonoscopy: Balancing efficacy, safety, cost and patient tolerance

    PubMed Central

    Harrison, Nicole M; Hjelkrem, Michael C

    2016-01-01

    Effective colorectal cancer screening relies on reliable colonoscopy findings which are themselves dependent on adequate bowel cleansing. Research has consistently demonstrated that inadequate bowel preparation adversely affects the adenoma detection rate and leads gastroenterologists to recommend earlier follow up than is consistent with published guidelines. Poor preparation affects as many as 30% of colonoscopies and contributes to an increased cost of colonoscopies. Patient tolerability is strongly affected by the preparation chosen and manner in which it is administered. Poor tolerability is, in turn, associated with lower quality bowel preparations. Recently, several new developments in both agents being used for bowel preparation and in the timing of administration have brought endoscopists closer to achieving the goal of effective, reliable, safe, and tolerable regimens. Historically, large volume preparations given in a single dose were administered to patients in order to achieve adequate bowel cleansing. These were poorly tolerated, and the unpleasant taste of and significant side effects produced by these large volume regimens contributed significantly to patients’ inability to reliably complete the preparation and to a reluctance to repeat the procedure. Smaller volumes, including preparations that are administered as tablets to be consumed with water, given as split doses have significantly improved both the patient experience and efficacy, and an appreciation of the importance of the preparation to colonoscopy interval have produced additional cleansing. PMID:26788258

  5. Use of Electronic Loggers to Measure Changes in the Rates of Hand Washing with Soap in Low-Income Urban Households in India

    PubMed Central

    Wright, Richard L.; Zillmer, Ruediger; Biran, Adam; Hall, Peter; Sidibe, Myriam

    2015-01-01

    We evaluated the utility of electronic loggers to measure the effects of a simple intervention designed to influence the rates of hand washing with soap within enclosed toilets and bathrooms in low-income urban households in Kerala, India. 58 households were given three items with embedded electronic loggers for a period of 2-5 days. Two logged soaps tracked hand and body washing in the bathroom. The third logged item was a water vessel used for flushing the toilet and for post-defecation anal cleansing; this served as a marker of toilet use. In addition, 28 households in a Soap by toilet arm were given an additional logged soap, to be kept by the toilet, and used for hand washing. Compared with the Soap in bathroom arm, the loggers in the Soap by toilet households recorded 73% greater daily use of soaps designated for hand washing (t(36)=2.92, p<0.01) and 172% greater use within 2 minutes of the use of the water vessel (t(36)=3.51, p = 0.001). We conclude that the loggers were capable of detecting changes in the rates of hand washing with soap and changes in hand washing with soap after use of the toilet. Further adoption of logger technologies would enable more insightful studies of hand washing within urban environments. PMID:26101886

  6. Use of Electronic Loggers to Measure Changes in the Rates of Hand Washing with Soap in Low-Income Urban Households in India.

    PubMed

    Wright, Richard L; Zillmer, Ruediger; Biran, Adam; Hall, Peter; Sidibe, Myriam

    2015-01-01

    We evaluated the utility of electronic loggers to measure the effects of a simple intervention designed to influence the rates of hand washing with soap within enclosed toilets and bathrooms in low-income urban households in Kerala, India. 58 households were given three items with embedded electronic loggers for a period of 2-5 days. Two logged soaps tracked hand and body washing in the bathroom. The third logged item was a water vessel used for flushing the toilet and for post-defecation anal cleansing; this served as a marker of toilet use. In addition, 28 households in a Soap by toilet arm were given an additional logged soap, to be kept by the toilet, and used for hand washing. Compared with the Soap in bathroom arm, the loggers in the Soap by toilet households recorded 73% greater daily use of soaps designated for hand washing (t(36)=2.92, p<0.01) and 172% greater use within 2 minutes of the use of the water vessel (t(36)=3.51, p = 0.001). We conclude that the loggers were capable of detecting changes in the rates of hand washing with soap and changes in hand washing with soap after use of the toilet. Further adoption of logger technologies would enable more insightful studies of hand washing within urban environments.

  7. Small bowel cleansing for capsule endoscopy in paediatric patients: a prospective randomized single-blind study.

    PubMed

    Oliva, Salvatore; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Ferrari, Federica; Civitelli, Fortunata; Pagliaro, Giuseppe; Di Nardo, Giovanni

    2014-01-01

    Small bowel cleansing by capsule endoscopy has never been addressed in children. Randomized controlled trial to evaluate the effect of five bowel preparation regimens on the mucosal visibility surface (as percentage of visualized surface area). Group A: a clear liquid diet for 12 h on the day before; Group B: high volume polyethylene glycol (50 mL/kg, up to 2Lt/die); Group C: low volume polyethylene glycol (25 mL/kg up to 1Lt/die); Group D: 20 mL (376 mg) of oral simethicone; Group E: 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone. Overall, 198 patients (53% male, median age 13 years) were enrolled. Preparation regimen visualization scores were 14.1 ± 4.2, 18.9 ± 5.1, 17.8 ± 5.5, 14.9 ± 4.8 and 20.9 ± 4.6 in groups A, B, C, D and E, respectively (P < 0.01). Positive findings were found in 172 cases (87%), but no significant differences were observed in the diagnostic yield and tolerability. Interobserver agreement, k = 0.89 (95% CI 0.83 ± 0.71). This is the first report in children that supports the use of 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone as the preparation of choice for capsule endoscopy. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  8. Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linguraru, Marius George; Panjwani, Neil; Fletcher, Joel G.

    2011-12-15

    Purpose: To evaluate the performance of a computer-aided detection (CAD) system for detecting colonic polyps at noncathartic computed tomography colonography (CTC) in conjunction with an automated image-based colon cleansing algorithm. Methods: An automated colon cleansing algorithm was designed to detect and subtract tagged-stool, accounting for heterogeneity and poor tagging, to be used in conjunction with a colon CAD system. The method is locally adaptive and combines intensity, shape, and texture analysis with probabilistic optimization. CTC data from cathartic-free bowel preparation were acquired for testing and training the parameters. Patients underwent various colonic preparations with barium or Gastroview in divided dosesmore » over 48 h before scanning. No laxatives were administered and no dietary modifications were required. Cases were selected from a polyp-enriched cohort and included scans in which at least 90% of the solid stool was visually estimated to be tagged and each colonic segment was distended in either the prone or supine view. The CAD system was run comparatively with and without the stool subtraction algorithm. Results: The dataset comprised 38 CTC scans from prone and/or supine scans of 19 patients containing 44 polyps larger than 10 mm (22 unique polyps, if matched between prone and supine scans). The results are robust on fine details around folds, thin-stool linings on the colonic wall, near polyps and in large fluid/stool pools. The sensitivity of the CAD system is 70.5% per polyp at a rate of 5.75 false positives/scan without using the stool subtraction module. This detection improved significantly (p = 0.009) after automated colon cleansing on cathartic-free data to 86.4% true positive rate at 5.75 false positives/scan. Conclusions: An automated image-based colon cleansing algorithm designed to overcome the challenges of the noncathartic colon significantly improves the sensitivity of colon CAD by approximately 15%.« less

  9. Widow cleansing and inheritance among the Luo in Kenya: the need for additional women-centred HIV prevention options

    PubMed Central

    Perry, Brian; Oluoch, Lennah; Agot, Kawango; Taylor, Jamilah; Onyango, Jacob; Ouma, Lilian; Otieno, Caroline; Wong, Christina; Corneli, Amy

    2014-01-01

    Introduction The customs of widow cleansing and widow inheritance are practiced in several communities throughout sub-Saharan Africa. In the Nyanza Province of Kenya, according to tradition, Luo widows are expected to engage in sexual intercourse with a “cleanser,” without the use of a condom, in order to remove the impurity ascribed to her after her husband's death. Luo couples, including widows, are also expected to engage in sex preceding specific agricultural activities, building homes, funerals, weddings, and other significant cultural and social events. Widows who are inherited for the purpose of fulfilling cultural obligation have a higher prevalence of HIV than those who remain un-inherited or are inherited for the purpose of companionship. Methods As part of a larger descriptive qualitative study to inform study procedures for FEM-PrEP, an HIV prevention pre-exposure prophylaxis clinical trial, we conducted 15 semi-structured interviews (SSIs) with widows, 15 SSIs with inheritors, and four focus group discussions with widows in the Bondo and Rarieda districts in Nyanza Province to explore the HIV risk context within widow cleansing and inheritance practices. Thematic qualitative analysis was used to analyze the data. Results The majority of widows reported in the demographic questionnaire being inherited, and most widows in the SSIs described participating in the cleansing ritual. We identified two main themes related to HIV prevention within the context of widow cleansing and inheritance: 1) widows must balance limiting their risk for HIV infection with meeting cultural expectations and ensuring that their livelihood needs are met, and 2) sexual abstinence undermines cultural expectations in widowhood while the use of condoms is deemed inappropriate in fulfilling culturally prescribed sexual rituals, and is often beyond the widow's ability to negotiate. Conclusions Women-controlled HIV prevention methods such as antiretroviral-based oral pre-exposure prophylaxis, vaginal gels, and vaginal rings are needed for HIV-negative widows who engage in sexual rituals related to widowhood. PMID:24973041

  10. Widow cleansing and inheritance among the Luo in Kenya: the need for additional women-centred HIV prevention options.

    PubMed

    Perry, Brian; Oluoch, Lennah; Agot, Kawango; Taylor, Jamilah; Onyango, Jacob; Ouma, Lilian; Otieno, Caroline; Wong, Christina; Corneli, Amy

    2014-01-01

    The customs of widow cleansing and widow inheritance are practiced in several communities throughout sub-Saharan Africa. In the Nyanza Province of Kenya, according to tradition, Luo widows are expected to engage in sexual intercourse with a "cleanser," without the use of a condom, in order to remove the impurity ascribed to her after her husband's death. Luo couples, including widows, are also expected to engage in sex preceding specific agricultural activities, building homes, funerals, weddings, and other significant cultural and social events. Widows who are inherited for the purpose of fulfilling cultural obligation have a higher prevalence of HIV than those who remain un-inherited or are inherited for the purpose of companionship. As part of a larger descriptive qualitative study to inform study procedures for FEM-PrEP, an HIV prevention pre-exposure prophylaxis clinical trial, we conducted 15 semi-structured interviews (SSIs) with widows, 15 SSIs with inheritors, and four focus group discussions with widows in the Bondo and Rarieda districts in Nyanza Province to explore the HIV risk context within widow cleansing and inheritance practices. Thematic qualitative analysis was used to analyze the data. The majority of widows reported in the demographic questionnaire being inherited, and most widows in the SSIs described participating in the cleansing ritual. We identified two main themes related to HIV prevention within the context of widow cleansing and inheritance: 1) widows must balance limiting their risk for HIV infection with meeting cultural expectations and ensuring that their livelihood needs are met, and 2) sexual abstinence undermines cultural expectations in widowhood while the use of condoms is deemed inappropriate in fulfilling culturally prescribed sexual rituals, and is often beyond the widow's ability to negotiate. Women-controlled HIV prevention methods such as antiretroviral-based oral pre-exposure prophylaxis, vaginal gels, and vaginal rings are needed for HIV-negative widows who engage in sexual rituals related to widowhood.

  11. Bending the Spear: The Campaign Against the Lord’s Resistance Army

    DTIC Science & Technology

    2017-12-01

    cleansing rituals alone. When people were killed, he purified them by himself.65 New members had to undertake rites of passage to be cleansed of witchcraft...of faith in his spiritual powers , and so would abduct UPDA soldiers and force them into the LRA when he encountered them away from their units.70...against Kony. Kony wanted to start an Acholi war. He wanted a Luo republic, wanted it to go to the Nile. People turned against him. When they said

  12. Potassium permanganate cleansing is an effective sanitary method for the reduction of bacterial bioload on raw Coriandrum sativum.

    PubMed

    Subramanya, Supram Hosuru; Pai, Vasudha; Bairy, Indira; Nayak, Niranjan; Gokhale, Shishir; Sathian, Brijesh

    2018-02-13

    Raw vegetables including flowers, leaves, stems, and roots are important carriers of food borne pathogens. We evaluated the bacteriological contamination of unwashed coriander leaves, and effectiveness of cleansing with 0.1% potassium permanganate solution as decontamination method. Significant bacterial contamination including pathogens like Salmonella species and Aeromonas species were isolated from unwashed coriander leaves. Decontamination with 0.1% potassium permanganate was found to be more effective than three steps wash with sterile water.

  13. 3D Printing of Plant Golgi Stacks from Their Electron Tomographic Models.

    PubMed

    Mai, Keith Ka Ki; Kang, Madison J; Kang, Byung-Ho

    2017-01-01

    Three-dimensional (3D) printing is an effective tool for preparing tangible 3D models from computer visualizations to assist in scientific research and education. With the recent popularization of 3D printing processes, it is now possible for individual laboratories to convert their scientific data into a physical form suitable for presentation or teaching purposes. Electron tomography is an electron microscopy method by which 3D structures of subcellular organelles or macromolecular complexes are determined at nanometer-level resolutions. Electron tomography analyses have revealed the convoluted membrane architectures of Golgi stacks, chloroplasts, and mitochondria. But the intricacy of their 3D organizations is difficult to grasp from tomographic models illustrated on computer screens. Despite the rapid development of 3D printing technologies, production of organelle models based on experimental data with 3D printing has rarely been documented. In this chapter, we present a simple guide to creating 3D prints of electron tomographic models of plant Golgi stacks using the two most accessible 3D printing technologies.

  14. Morality and soap in engineers and social scientists: the Macbeth effect interacts with professions.

    PubMed

    Schaefer, Michael

    2017-11-07

    Several studies demonstrate that physical cleansing is actually efficacious to cope with threatened morality, thus demonstrating that physical and moral purity are psychologically interwoven. This so-called Macbeth effect has been explained, for example, by the conceptual metaphor theory that suggests an embodiment of the moral purity metaphor. Recent research draws attention to individual differences when using conceptual metaphors. The present study shows that the moral purity link interacts with different professions. Engineering and social science students were asked to hand copy a text in which the protagonist behaved in an immoral way (or in a moral way, control condition). Subsequently, they had to rate cleansing and other products. Both groups of participants showed higher ratings for cleansing products when hand copying the unethical story, but this Macbeth effect was significantly stronger for the group of engineering students. The results demonstrate that the Macbeth effect interacts with individual differences of the chosen profession. The outcome is discussed in terms of recent theories on individual differences in disgust sensitivity.

  15. Use of a verbal electronic audio reminder with a patient hand hygiene bundle to increase independent patient hand hygiene practices of older adults in an acute care setting.

    PubMed

    Knighton, Shanina C; Dolansky, Mary; Donskey, Curtis; Warner, Camille; Rai, Herleen; Higgins, Patricia A

    2018-06-01

    We hypothesized that the addition of a novel verbal electronic audio reminder to an educational patient hand hygiene bundle would increase performance of self-managed patient hand hygiene. We conducted a 2-group comparative effectiveness study randomly assigning participants to patient hand hygiene bundle 1 (n = 41), which included a video, a handout, and a personalized verbal electronic audio reminder (EAR) that prompted hand cleansing at 3 meal times, or patient hand hygiene bundle 2 (n = 34), which included the identical video and handout, but not the EAR. The primary outcome was alcohol-based hand sanitizer use based on weighing bottles of hand sanitizer. Participants that received the EAR averaged significantly more use of hand sanitizer product over the 3 days of the study (mean ± SD, 29.97 ± 17.13 g) than participants with no EAR (mean ± SD, 10.88 ± 9.27 g; t 73  = 5.822; P ≤ .001). The addition of a novel verbal EAR to a patient hand hygiene bundle resulted in a significant increase in patient hand hygiene performance. Our results suggest that simple audio technology can be used to improve patient self-management of hand hygiene. Future research is needed to determine if the technology can be used to promote other healthy behaviors, reduce infections, and improve patient-centered care without increasing the workload of health care workers. Published by Elsevier Inc.

  16. Intravaginal and Menstrual Practices among Women Working in Food and Recreational Facilities in Mwanza, Tanzania: Implications for Microbicide Trials

    PubMed Central

    Desmond, Nicola; Chiduo, Betty; Medard, Lemmy; Lees, Shelley S.; Vallely, Andrew; Francis, Suzanna C.; Ross, David A.; Hayes, Richard J.

    2010-01-01

    Intravaginal and menstrual practices may potentially influence results of trials of microbicides for HIV prevention through effects on the vaginal environment and on adherence to microbicide and placebo products. As part of the feasibility study for the Microbicides Development Programme Phase 3 trial of a vaginal microbicide in Mwanza, a variety of quantitative and qualitative methods were used to describe these practices, associations with behaviour and underlying social norms among women working in food and recreational facilities. Intravaginal cleansing by inserting fingers and either water alone or soap and water was thought necessary to remove “uchafu” (dirt), referring to vaginal secretions, including menstrual blood and post-coital discharge. Vaginal cleansing was carried out within 2 hours after 45% of sex acts. Sexual enhancement practices were less common. Intravaginal and menstrual practices and associated behaviours and demographic factors should be measured and monitored throughout microbicide trials to enable analyses of their impacts on microbicide effectiveness. PMID:20665101

  17. Combined low-volume polyethylene glycol solution plus stimulant laxatives versus standard-volume polyethylene glycol solution: A prospective, randomized study of colon cleansing before colonoscopy

    PubMed Central

    Hookey, Lawrence C; Depew, William T; Vanner, Stephen J

    2006-01-01

    INTRODUCTION The effectiveness of polyethylene glycol solutions (PEG) for colon cleansing is often limited by the inability of patients to drink adequate portions of the 4 L solution. The aim of the present study was to determine whether a reduced volume of PEG combined with stimulant laxatives would be better tolerated and as or more effective than the standard dose. METHODS Patients undergoing outpatient colonoscopy were randomly assigned to receive either low-volume PEG plus sennosides (120 mg oral sennosides syrup followed by 2 L PEG) or the standard volume preparation (4 L PEG). The subjects rated the tolerability of the preparations and their symptoms. Colonoscopists were blind to the colonic cleansing preparation and graded the cleansing efficacy using a validated tool (the Ottawa scale). RESULTS The low-volume PEG plus sennosides preparation was significantly better tolerated than the standard large volume PEG (P<0.001) but was less efficacious (P=0.03). Thirty-eight per cent of patients in the large volume PEG group were unable to finish the preparation, compared with only 6% in the reduced volume group. There were no adverse events reported. CONCLUSIONS Although the low-volume PEG plus sennosides preparation was better tolerated, it was not as effective as standard large-volume PEG. However, in view of the significant difference in tolerance, further research investigating possible improvements in the reduced-volume regimen seems warranted. PMID:16482236

  18. Moisture content and gas sampling device

    NASA Technical Reports Server (NTRS)

    Krieg, H. C., Jr. (Inventor)

    1985-01-01

    An apparatus is described for measuring minute quantities of moisture and other contaminants within sealed enclosures such as electronic assemblies which may be subject to large external atmospheric pressure variations. An array of vacuum quality valves is arranged to permit cleansing of the test apparatus of residual atmospheric components from a vacuum source. This purging operation evacuates a gas sample bottle, which is then connected by valve settings to provide the drive for withdrawing a gas sample from the sealed enclosure under test into the sample bottle through a colometric detector tube (Drager tube) which indicates moisture content. The sample bottle may be disconnected and its contents (drawn from the test enclosure) separately subjected to mass spectrograph analysis.

  19. Development and efficacy assessments of tea seed oil makeup remover.

    PubMed

    Parnsamut, N; Kanlayavattanakul, M; Lourith, N

    2017-05-01

    The efficacy of tea seed oil to clean foundation and eyeliner was evaluated. The safe and efficient tea seed oil makeup remover was developed. In vitro cleansing efficacy of makeup remover was UV-spectrophotometric validated. The stability evaluation by means of accelerated stability test was conducted. In vitro and in vivo cleansing efficacy of the removers was conducted in a comparison with benchmark majorly containing olive oil. Tea seed oil cleaned 90.64±4.56% of foundation and 87.62±8.35% of eyeliner. The stable with most appropriate textures base was incorporated with tea seed oil. Three tea seed oil removers (50, 55 and 60%) were stabled. The 60% tea seed oil remover significantly removed foundation better than others (94.48±3.37%; P<0.001) and the benchmark (92.32±1.33%), but insignificant removed eyeliner (87.50±5.15%; P=0.059). Tea seed oil remover caused none of skin irritation as examined in 20 human volunteers. A single-blind, randomized control exhibited that the tea seed oil remover gained a better preference over the benchmark (75.42±8.10 and 70.00±7.78%; P=0.974). The safe and efficient tea seed oil makeup removers had been developed. The consumers' choices towards the makeup remover containing the bio-oils are widen. In vitro cleansing efficacy during the course of makeup remover development using UV-spectrophotometric method feasible for pharmaceutic industries is encouraged. Copyright © 2016 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  20. Electronic structure and magnetic anisotropy of L1{sub 0}-FePt thin film studied by hard x-ray photoemission spectroscopy and first-principles calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueda, S.; Synchrotron X-ray Station at SPring-8, National Institute for Materials Science, Sayo, Hyogo 679-5148; Mizuguchi, M.

    2016-07-25

    We have studied the electronic structure of the L1{sub 0} ordered FePt thin film by hard x-ray photoemission spectroscopy (HAXPES), cluster model, and first-principles calculations to investigate the relationship between the electronic structure and perpendicular magneto-crystalline anisotropy (MCA). The Fe 2p core-level HAXPES spectrum of the ordered film revealed the strong electron correlation in the Fe 3d states and the hybridization between the Fe 3d and Pt 5d states. By comparing the experimental valence band structure with the theoretical density of states, the strong electron correlation in the Fe 3d states modifies the valence band electronic structure of the L1{submore » 0} ordered FePt thin film through the Fe 3d-Pt 5d hybridization. These results strongly suggest that the strong electron correlation effect in the Fe 3d states and the Fe 3d-Pt 5d hybridization as well as the spin-orbit interaction in the Pt 5d states play important roles in the perpendicular MCA for L1{sub 0}-FePt.« less

  1. Neglected aspects in the management of acne.

    PubMed Central

    Gordon, B

    1985-01-01

    Acne is the result of excessive grease on the skin. The successful treatment of acne depends essentially on the degreasing of the skin to an extent which produces peeling, which is the observable index of adequate treatment. The use of antibiotics is supplementary to degreasing and peeling. Degreasing is best achieved by thrice daily washing with Neutrogena acne cleansing soap, followed by the application of a benzoyl peroxide preparation of a suitable strength. If necessary, further degreasing can be achieved by cleansing with isopropyl alcohol after washing with the Neutrogena soap. PMID:2941579

  2. Efficacy of citric acid denture cleanser on the Candida albicans biofilm formed on poly(methyl methacrylate): effects on residual biofilm and recolonization process.

    PubMed

    Faot, Fernanda; Cavalcanti, Yuri Wanderley; Mendonça e Bertolini, Martinna de; Pinto, Luciana de Rezende; da Silva, Wander José; Cury, Altair Antoninha Del Bel

    2014-06-23

    It is well known that the use of denture cleansers can reduce Candida albicans biofilm accumulation; however, the efficacy of citric acid denture cleansers is uncertain. In addition, the long-term efficacy of this denture cleanser is not well established, and their effect on residual biofilms is unknown. This in vitro study evaluated the efficacy of citric acid denture cleanser treatment on C. albicans biofilm recolonization on poly(methyl methacrylate) (PMMA) surface. C. albicans biofilms were developed for 72 h on PMMA resin specimens (n = 168), which were randomly assigned to 1 of 3 cleansing treatments (CTs) overnight (8 h). CTs included purified water as a control (CTC) and two experimental groups that used either a 1:5 dilution of citric acid denture cleanser (CT5) or a 1:8 dilution of citric acid denture cleanser (CT8). Residual biofilms adhering to the specimens were collected and quantified at two time points: immediately after CTs (ICT) and after cleaning and residual biofilm recolonization (RT). Residual biofilms were analyzed by quantifying the viable cells (CFU/mL), and biofilm architecture was evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Denture cleanser treatments and evaluation periods were considered study factors. Data were analyzed using two-way ANOVA and Tukey's Honestly Significant Difference (HSD) test (α = 0.05). Immediately after treatments, citric acid denture cleansing solutions (CT5 and CT8) reduced the number of viable cells as compared with the control (p < 0.01). However, after 48 h, both CT groups (CT5 and CT8) showed biofilm recolonization (p < 0.01). Residual biofilm recolonization was also detected by CLSM and SEM analysis, which revealed a higher biomass and average biofilm thickness for the CT8 group (p < 0.01). Citric acid denture cleansers can reduce C. albicans biofilm accumulation and cell viability. However, this CT did not prevent biofilm recolonization.

  3. High Resolution Electron Microbeam Examination and 3D Reconstruction of Alligator Gar Scale

    DTIC Science & Technology

    2016-06-27

    Distribution Unlimited UU UU UU UU 27-06-2016 15-Nov-2012 14-Nov-2015 Final Report: High Resolution Electron Microbeam Examination and 3D ...ADDRESS (ES) U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 Alligator Gar Fish, 3D characterization, Electron...Resolution Electron Microbeam Examination and 3D reconstruction of Alligator Gar Scale Report Title Engineered laminate composites have been widely used

  4. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation.

    PubMed

    Walter, Benjamin Michael; Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-06-21

    In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective of this study was to assess the function of an automated text messaging (short message service, SMS)-supported colonoscopy preparation starting 4 days before colonoscopy appointment. After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging-provided information assessed by a questionnaire. Web-based SMS text messaging-supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging-based information was high. Using SMS for colonoscopy preparation with 4 days' guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation.

  5. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation

    PubMed Central

    Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-01-01

    Background In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective Objective of this study was to assess the function of an automated text messaging (short message service, SMS)–supported colonoscopy preparation starting 4 days before colonoscopy appointment. Methods After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging–provided information assessed by a questionnaire. Results Web-based SMS text messaging–supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging–based information was high. Conclusions Using SMS for colonoscopy preparation with 4 days’ guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation. PMID:27329204

  6. Multicenter, randomized study to optimize bowel preparation for colon capsule endoscopy

    PubMed Central

    Kastenberg, David; Jr, Wilmot C Burch; Romeo, David P; Kashyap, Pankaj K; Pound, David C; Papageorgiou, Neophytos; Sainz, Ignacio Fernández-Urien; Sokach, Carly E; Rex, Douglas K

    2017-01-01

    AIM To assess the cleansing efficacy and safety of a new Colon capsule endoscopy (CCE) bowel preparation regimen. METHODS This was a multicenter, prospective, randomized, controlled study comparing two CCE regimens. Subjects were asymptomatic and average risk for colorectal cancer. The second generation CCE system (PillCam® COLON 2; Medtronic, Yoqneam, Israel) was utilized. Preparation regimens differed in the 1st and 2nd boosts with the Study regimen using oral sulfate solution (89 mL) with diatrizoate meglumine and diatrizoate sodium solution (“diatrizoate solution”) (boost 1 = 60 mL, boost 2 = 30 mL) and the Control regimen oral sulfate solution (89 mL) alone. The primary outcome was overall and segmental colon cleansing. Secondary outcomes included safety, polyp detection, colonic transit, CCE completion and capsule excretion ≤ 12 h. RESULTS Both regimens had similar cleansing efficacy for the whole colon (Adequate: Study = 75.9%, Control = 77.3%; P = 0.88) and individual segments. In the Study group, CCE completion was superior (Study = 90.9%, Control = 76.9%; P = 0.048) and colonic transit was more often < 40 min (Study = 21.8%, Control = 4%; P = 0.0073). More Study regimen subjects experienced adverse events (Study = 19.4%, Control = 3.4%; P = 0.0061), and this difference did not appear related to diatrizoate solution. Adverse events were primarily gastrointestinal in nature and no serious adverse events related either to the bowel preparation regimen or the capsule were observed. There was a trend toward higher polyp detection with the Study regimen, but this did not achieve statistical significance for any size category. Mean transit time through the entire gastrointestinal tract, from ingestion to excretion, was shorter with the Study regimen while mean colonic transit times were similar for both study groups. CONCLUSION A CCE bowel preparation regimen using oral sulfate solution and diatrizoate solution as a boost agent is effective, safe, and achieved superior CCE completion. PMID:29358870

  7. Intra- and inter-atomic optical transitions of Fe, Co, and Ni ferrocyanides studied using first-principles many-electron calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watanabe, Shinta, E-mail: s-watanabe@nucl.nagoya-u.ac.jp, E-mail: j-onoe@nucl.nagoya-u.ac.jp; Sawada, Yuki; Nakaya, Masato

    We have investigated the electronic structures and optical properties of Fe, Co, and Ni ferrocyanide nanoparticles using first-principles relativistic many-electron calculations. The overall features of the theoretical absorption spectra for Fe, Ni, and Co ferrocyanides calculated using a first-principles many-electron method well reproduced the experimental one. The origins of the experimental absorption spectra were clarified by performing a configuration analysis based on the many-electron wave functions. For Fe ferrocyanide, the experimental absorption peaks originated from not only the charge-transfer transitions from Fe{sup 2+} to Fe{sup 3+} but also the 3d-3d intra-transitions of Fe{sup 3+} ions. In addition, the spin crossovermore » transition of Fe{sup 3+} predicted by the many-electron calculations was about 0.24 eV. For Co ferrocyanide, the experimental absorption peaks were mainly attributed to the 3d-3d intra-transitions of Fe{sup 2+} ions. In contrast to the Fe and Co ferrocyanides, Ni ferrocyanide showed that the absorption peaks originated from the 3d-3d intra-transitions of Ni{sup 3+} ions in a low-energy region, while from both the 3d-3d intra-transitions of Fe{sup 2+} ions and the charge-transfer transitions from Fe{sup 2+} to Ni{sup 3+} in a high-energy region. These results were quite different from those of density-functional theory (DFT) calculations. The discrepancy between the results of DFT calculations and those of many-electron calculations suggested that the intra- and inter-atomic transitions of transition metal ions are significantly affected by the many-body effects of strongly correlated 3d electrons.« less

  8. Strong Inter-channel Effects in Dipole Photoionization of d-subshells of Xe, Cs, and Ba Atoms

    NASA Astrophysics Data System (ADS)

    Manson, S.; Amusia, M.; Baltenkov, A.; Chernysheva, L.; Felfli, Z.; Msezane, A.

    2003-05-01

    In the framework of a specially modified Random Phase Approximation with Exchange approach (SPRPAE) developed for half-filled atomic subshells the dipole angular anisotropy parameters β(ω) for the 3d-photoionization of Xe, Cs and Ba atoms have been calculated. The main point of this approach is that we consider the 3d electrons of these atoms as belonging to two semi-filled atomic levels that contain two different sorts of electrons, namely that six electrons form the 3d_5/2 subshell (called "up"), while the other four electrons form the 3d_3/2 subshell (called "down"). This permits to apply straightforwardly the RPAE for these semi-filled subshells. We show that the interaction between "up" and "down" electrons results in a qualitative alteration of the frequency (ω) dependence of β_5/2(ω) and β_3/2(ω) that define the photoelectron angular distribution from the 3d_5/2 and 3d_3/2 levels. In all these atoms the effect of 3d_3/2 upon 3d_5/2 leads to the creation of an additional maximum near the photoionization thresholds, while the effect for 3d_3/2 is rather weak. Work supported by CRDF (No ZP1- 2449-TA-02), ISTC grant 1358 and NSF

  9. Low-volume bowel preparation is inferior to standard 4 1 polyethylene glycol.

    PubMed

    Haapamäki, Markku M; Lindström, Monica; Sandzén, Birger

    2011-03-01

    Four liters or more of orally taken polyethylene glycol solution (PEG) has proved to be an effective large-bowel cleansing method prior to colonoscopy. The problem has been the large volume of fluid and its taste, which is unacceptable to some examinees. We aimed to investigate the effectiveness of 2 l PEG combined with senna compared with 4 l PEG for bowel preparation. The design was a single-center, prospective, randomized, investigator-blinded study with parallel assignment, in the setting of the Endoscopy Unit of Umeå University Hospital. Outpatients (n = 490) scheduled for colonoscopy were enrolled. The standard-volume arm received 4 l PEG, and the low-volume arm received 36 mg senna glycosides in tablets and 2 l PEG. The cleansing result (primary endpoint) was assessed by the endoscopist using the Ottawa score. The patients rated the subjective grade of ease of taking the bowel preparation. Analysis was on an intention-to-treat basis. There were significantly more cases with poor or inadequate bowel cleansing after the low-volume alternative with senna and 2 l PEG (22/203) compared with after 4 l PEG (8/196, p = 0.027). The low-volume alternative was better tolerated by the examinees: 119/231 rated the treatment as easy to take compared with 88/238 in the 4 l PEG arm (p = 0.001). 4 l PEG treatment is better than 36 mg senna and 2 l PEG as routine colonic cleansing before colonoscopy because of fewer failures.

  10. 2-Litre polyethylene glycol-citrate-simethicone plus bisacodyl versus 4-litre polyethylene glycol as preparation for colonoscopy in chronic constipation.

    PubMed

    Parente, Fabrizio; Vailati, Cristian; Bargiggia, Stefano; Manes, Gianpiero; Fontana, Paola; Masci, Enzo; Arena, Monica; Spinzi, Giancarlo; Baccarin, Alessandra; Mazzoleni, Giorgia; Testoni, Pier Alberto

    2015-10-01

    Chronic constipation is a risk factor of inadequate bowel preparation for colonoscopy; however, no large clinical trials have been performed in this subgroup of patients. To compare bowel cleansing efficacy, tolerability and acceptability of 2-L polyethylene-glycol-citrate-simethicone (PEG-CS) plus 2-day bisacodyl (reinforced regimen) vs. 4-L PEG in patients with chronic constipation undergoing colonoscopy. Randomized, observer-blind, parallel group study. Adult outpatients undergoing colonoscopy were randomly allocated to 2-L PEG-CS/bisacodyl or 4-L PEG, taken as split regimens before colonoscopy. Quality of bowel preparation was assessed by the Ottawa Bowel Cleansing Scale (OBCS). The amount of foam/bubble interfering with colonic visualization was also measured. 400 patients were enrolled. There was no significant difference in successful cleansing (OBCS score ≤6): 80.2% in the 2-L PEG-CS/bisacodyl vs. 81.4% in the 4-L PEG group. Significantly more patients taking 2L PEG-CS/bisacodyl showed no or minimal foam/bubbles in all colonic segments (80% vs. 63%; p<0.001). 2-L PEG-CS/bisacodyl was significantly more acceptable for ease of administration (p<0.001), willingness to repeat (p<0.001) and showed better compliance (p=0.002). Split 2-L PEG-CS plus bisacodyl was not superior to split 4-L PEG for colonoscopy bowel cleansing in patients with chronic constipation; however, it performed better than the standard regimen in terms of colonic mucosa visualization, patient acceptance and compliance. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Bowel preparation for colonoscopy: state of the art.

    PubMed

    Voiosu, Theodor; Voiosu, Andrei; Voiosu, Radu

    2016-07-13

    Bowel preparation for colonoscopy is a key quality indicator that impacts on all aspects of the procedure, such as patient comfort, diagnostic yield, and adverse events. Although most laxative regimens currently employed have been compared in a multitude of settings, the optimal preparation regimen still remains an open question. Recent studies have focused on developing new regimens by modifying dosage, timing of administration or by combining laxatives with synergic mechanisms of action with the purpose of increasing patient tolerability while maximizing bowel cleansing. Several low-volume preparations and combinations of laxatives and adjunctive medication have shown promise in delivering both adequate preparation of the colon and good patient tolerability. Also, we have gained a better understanding of the influence of patient-related factors such as health literacy and education on the quality of bowel preparation. Although several novel regimens have been tested in recent trials, it remains unclear which, if any, of these bowel preparations can replace the standard bowel cleansing regimens in clinical practice. Also, further data are required on how to improve bowel cleansing by choosing the appropriate regimen for the individual patient.

  12. Whole body cleaning agent containing N-acyltaurate

    NASA Technical Reports Server (NTRS)

    Lentsch, Steven E. (Inventor)

    1992-01-01

    The subject invention relates to a human cleansing agent particularly suitable for use in long duration spaceflight and to a method of bathing with the agent. The agent of the subject invention is in the form of a paste having a pH of 5.0 to 7.9 which comprises an acyltaurate, a skin conditioner, a hair conditioner, and a preservative. More specifically, it includes sodium N-coconut acid-N-methyl taurate, in combination with soybean lecithin, polyquaternium 16, and formalin. This particular combination satisfies the following objectives: (1) that it be usable with a minimum amount of water per shower (approximately 1 gallon); (2) that it be easily separated from the water for purposes of water reclamation; (3) that it be pH compatible with skin and hair; (4) that it rinse well in deionized water; (5) that it be mild to skin and eyes; (6) that it effectively clean both skin and hair; (7) that it be suitable for use in zero gravity; and (8) that it provide ease of combing of wet and dry hair. The method of the invention includes the steps of wetting the skin and hair with a small quantity of water, lathering the skin with the paste, rinsing the lather from the skin and hair with a small quantity of water to produce a rinse water containing the cleansing agent, defoaming the rinse water, and supplying the defoamed rinse water to a water reclamation unit for recycling the water. The novelty of the invention appears to lie in the particular formulation of the cleansing agent and its method of use which provide optimal results under the given constraints and objectives.

  13. Effect of yogic colon cleansing (Laghu Sankhaprakshalana Kriya) on pain, spinal flexibility, disability and state anxiety in chronic low back pain

    PubMed Central

    Haldavnekar, Richa Vivek; Tekur, Padmini; Nagarathna, Raghuram; Nagendra, Hongasandra Ramarao

    2014-01-01

    Background: Studies have shown that Integrated Yoga reduces pain, disability, anxiety and depression and increases spinal flexibility and quality-of-life in chronic low back pain (CLBP) patients. Objective: The objective of this study was to compare the effect of two yoga practices namely laghu shankha prakshalana (LSP) kriya, a yogic colon cleansing technique and back pain specific asanas (Back pain special technique [BST]) on pain, disability, spinal flexibility and state anxiety in patients with CLBP. Materials and Methods: In this randomized control (self as control) study, 40 in-patients (25 were males, 15 were females) between 25 and 70 years (44.05 ± 13.27) with CLBP were randomly assigned to receive LSP or BST sessions. The measurements were taken immediately before and after each session of either of the practices (30 min) in the same participant. Randomization was used to decide the day of the session (3rd or 5th day after admission) to ensure random distribution of the hang over effect of the two practices. Statistical analysis was performed using the repeated measures analysis of variance. Results: Significant group * time interaction (P < 0.001) was observed in 11 point numerical rating scale, spinal flexibility (on Leighton type Goniometer) and (straight leg raise test in both legs), Oswestry Disability Index, State Anxiety (XI component of Spieldberger's state and trait anxiety inventory. There was significantly (P < 0.001, between groups) better reduction in LSP than BST group on all variables. No adverse effects were reported by any participant. Conclusion: Clearing the bowel by yoga based colon cleansing technique (LSP) is safe and offers immediate analgesic effect with reduced disability, anxiety and improved spinal flexibility in patients with CLBP. PMID:25035620

  14. Prototype wash water renovation system integration with government-furnished wash fixture

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The requirements of a significant quantity of proposed life sciences experiments in Shuttle payloads for available wash water to support cleansing operations has provided the incentive to develop a technique for wash water renovation. A prototype wash water waste renovation system which has the capability to process the waste water and return it to a state adequate for reuse in a typical cleansing fixture designed to support life science experiments was investigated. The resulting technology is to support other developments efforts pertaining to water reclamation by serving as a pretreatment step for subsequent reclamation procedures.

  15. [Persistent reddening and induration after wound cleansing with octenidine].

    PubMed

    Seegräber, M; T Ruzicka; Wollenberg, A

    2017-04-01

    With its long-lasting effectiveness, octenidine is an agent of first choice for antiseptic wound treatment. However, the manufacturer advises against instillation of the agent under pressure. A 50-year-old patient presented with erythema and extensive soft tissue induration after wound cleansing with octenidine under pressure. Due to the lack of resorption of the agent, this caused long-lasting interstitial soft tissue edema. This case demonstrates the importance of following the manufacturer's instructions for use. Advantages of the agent such as lack of systemic toxicity or broad spectrum efficacy can only be achieved if the agent is applied correctly.

  16. Pin site care for preventing infections associated with external bone fixators and pins.

    PubMed

    Lethaby, Anne; Temple, Jenny; Santy-Tomlinson, Julie

    2013-12-03

    Metal pins are used to apply skeletal traction or external fixation devices in the management of orthopaedic fractures. These percutaneous pins protrude through the skin, and the way in which they are treated after insertion may affect the incidence of pin site infection. This review set out to summarise the evidence of pin site care on infection rates. To assess the effect on infection rates of different methods of cleansing and dressing orthopaedic percutaneous pin sites. In September 2013, for this third update, we searched the Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We evaluated all randomised controlled trials (RCTs) that compared the effect on infection and other complication rates of different methods of cleansing or dressing orthopaedic percutaneous pin sites. Two review authors independently assessed the citations retrieved by the search strategies for reports of relevant RCTs, then independently selected trials that satisfied the inclusion criteria, extracted data and undertook quality assessment. A total of eleven trials (572 participants) were eligible for inclusion in the review but not all participants contributed data to each comparison. Three trials compared a cleansing regimen (saline, alcohol, hydrogen peroxide or antibacterial soap) with no cleansing (application of a dry dressing), three trials compared alternative sterile cleansing solutions (saline, alcohol, peroxide, povidone iodine), three trials compared methods of cleansing (one trial compared identical pin site care performed daily or weekly and the two others compared sterile with non sterile techniques), one trial compared daily pin site care with no care and six trials compared different dressings (using different solutions/ointments and dry and impregnated gauze or sponges). One small blinded study of 38 patients found that the risk of pin site infection was significantly reduced with polyhexamethylene biguanide (PHMB) gauze when compared to plain gauze (RR 0.23, 95% CI 0.12 to 0.44) (infection rate of 1% in the PHMB group and 4.5% in the control group) but this study was at high risk of bias as the unit of analysis was observations rather than patients. There were no other statistically significant differences between groups in any of the other trials. The available trial evidence was not extensive, was very heterogeneous and generally of poor quality, so there was insufficient evidence to be able to identify a strategy of pin site care that minimises infection rates. Adequately-powered randomised trials are required to examine the effects of different pin care regimens, and co-interventions - such as antibiotic use - and other extraneous factors must be controlled in the study designs.

  17. Three dimensional particle-in-cell simulations of electron beams created via reflection of intense laser light from a water target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ngirmang, Gregory K., E-mail: ngirmang.1@osu.edu; Orban, Chris; Feister, Scott

    We present 3D Particle-in-Cell (PIC) modeling of an ultra-intense laser experiment by the Extreme Light group at the Air Force Research Laboratory using the Large Scale Plasma (LSP) PIC code. This is the first time PIC simulations have been performed in 3D for this experiment which involves an ultra-intense, short-pulse (30 fs) laser interacting with a water jet target at normal incidence. The laser-energy-to-ejected-electron-energy conversion efficiency observed in 2D(3v) simulations were comparable to the conversion efficiencies seen in the 3D simulations, but the angular distribution of ejected electrons in the 2D(3v) simulations displayed interesting differences with the 3D simulations' angular distribution;more » the observed differences between the 2D(3v) and 3D simulations were more noticeable for the simulations with higher intensity laser pulses. An analytic plane-wave model is discussed which provides some explanation for the angular distribution and energies of ejected electrons in the 2D(3v) simulations. We also performed a 3D simulation with circularly polarized light and found a significantly higher conversion efficiency and peak electron energy, which is promising for future experiments.« less

  18. Coexistence of two electronic nano-phases on a CH 3NH 3PbI 3–xCl x surface observed in STM measurements

    DOE PAGES

    Yost, Andrew J.; Pimachev, Artem; Ho, Chun -Chih; ...

    2016-10-10

    Scanning tunneling microscopy is utilized to investigate the local density of states of a CH 3NH 3PbI 3-xCl x perovskite in cross-sectional geometry. Two electronic phases, 10-20 nm in size, with different electronic properties inside the CH 3NH 3PbI 3-xCl x perovskite layer are observed by the dI/ dV mapping and point spectra. A power law dependence of the dI/dV point spectra is revealed. In addition, the distinct electronic phases are found to have preferential orientations close to the normal direction of the film surface. Density functional theory calculations indicate that the observed electronic phases are associated with local deviationmore » of I/Cl ratio, rather than different orientations of the electric dipole moments in the ferroelectric phases. Furthermore, by comparing the calculated results with experimental data we conclude that phase A (lower contrast in dI/dV mapping at -2.0 V bias) contains a lower I/Cl ratio than that in phase B (higher contrast in dI/dV).« less

  19. Strain effects on the electronic properties in δ -doped oxide superlattices

    DOE PAGES

    You, Jeong Ho; Lee, Jun Hee; Okamoto, Satoshi; ...

    2015-02-07

    We investigated strain effects on the electronic properties of (LaTiO 3) 1/(SrTiO 3)N superlattices using density functional theory. Under biaxial in-plane strain within the range of -5% ≤ ε// ≤ 5%, the d xy orbital electrons are highly localized at the interfaces whereas the d yz and d xz orbital electrons are more distributed in the SrTiO 3 (STO) spacer layers. For STO thickness N ≥ 3 unit cells (u.c.), the d xy orbital electrons form two-dimensional (2D) electron gases (2DEGs). The quantized energy levels of the 2DEG are insensitive to the STO spacer thickness, but are strongly dependent onmore » the applied biaxial in-plane strain. As the in-plane strain changes from compressive to tensile, the quantized energy levels of the dxy orbitals decrease thereby creating more states with 2D character. In contrast to the d xy orbital, the d yz and dxz orbitals always have three-dimensional (3D) transport characteristics and their energy levels increase as the strain changes from compressive to tensile. In conclusion, since the charge densities in the d xy orbital and the d yz and d xz orbitals respond to biaxial in-plane strain in an opposite way, the transport dimensionality of the majority carriers can be controlled between 2D and 3D by applying biaxial in-plane strain.« less

  20. Temperature-dependent band structure of SrTiO3 interfaces

    NASA Astrophysics Data System (ADS)

    Raslan, Amany; Lafleur, Patrick; Atkinson, W. A.

    2017-02-01

    We build a theoretical model for the electronic properties of the two-dimensional (2D) electron gas that forms at the interface between insulating SrTiO3 and a number of polar cap layers, including LaTiO3, LaAlO3, and GdTiO3. The model treats conduction electrons within a tight-binding approximation and the dielectric polarization via a Landau-Devonshire free energy that incorporates strontium titanate's strongly nonlinear, nonlocal, and temperature-dependent dielectric response. The self-consistent band structure comprises a mix of quantum 2D states that are tightly bound to the interface and quasi-three-dimensional (3D) states that extend hundreds of unit cells into the SrTiO3 substrate. We find that there is a substantial shift of electrons away from the interface into the 3D tails as temperature is lowered from 300 K to 10 K. This shift is least important at high electron densities (˜1014cm-2 ) but becomes substantial at low densities; for example, the total electron density within 4 nm of the interface changes by a factor of two for 2D electron densities ˜1013cm-2 . We speculate that the quasi-3D tails form the low-density high-mobility component of the interfacial electron gas that is widely inferred from magnetoresistance measurements.

  1. Irritancy ranking of 31 cleansers in the Indian market in a 24-h patch test.

    PubMed

    Lakshmi, C; Srinivas, C R; Anand, C V; Mathew, A C

    2008-08-01

    Cleansing trends promise freshness, sensory and health benefits but may also be accompanied by an increase in soap-induced skin irritation. The aim of this study was to evaluate the irritant effect of 31 cleansers (28 bar soaps and 3 liquid cleansers) available in the Indian market. Eight percent w/v solutions of the soaps/cleansers were made and 30 microL of each of the solutions were applied to Finn chambers and occluded for 24 h along with distilled water (negative control) and 20% sodium dodecyl sulphate (SDS) as positive control. The sites were graded for erythema and scaling 30 min after removing the patches. The pH of each of the soap solutions was determined. Mean with SD and ANOVA (F-value) was computed separately for each soap/cleanser with respect to the two parameters, erythema and scaling. The total of the means for both the parameters, erythema and scaling was also computed. The cleansers were listed based on this total from the least irritant to the most irritant. The differences between soaps (F-value) was significant for erythema and scaling [erythema = 4.106 (P = 0.000); scaling = 6.006 (P = 0.000)]. Cetaphil cleansing lotion had the lowest erythema score of 0.25. Lowest scaling score of zero was recorded for Cetaphil cleansing lotion and Elovera moisturizing body wash. Aquasoft and Lifebuoy soaps had the highest erythema score of 2.13. Acnex had the highest scaling score of 1.75; Aquasoft, Hamam scrub bath soap and Naturepower sandal soaps were the next with a scaling score of 1.63. Cetaphil cleansing lotion, Aquaderm liquid soap, Dove bar soap and Elovera moisturizing body wash proved to be the least irritant cleansers with a total score of less than 1. The four most irritant soaps/cleansers had an average score of 3.65. The irritant potential of the majority of the cleansers fell between these extremes. The pH of all the soap/cleanser solutions was neutral to alkaline (pH 7-9) except that of Dove bar, Cetaphil cleansing lotion, Aquaderm liquid soap and Elovera moisturizing body wash which tested acidic (pH 5-6). The pH of the positive control--20% SDS, was acidic (pH 6). The difference in the irritancy potential between soaps/cleansers as determined by the 24-h patch test was significant. There were individual variations in the irritant potential of the soaps/cleansers in the volunteers, thus when the patient queries on what soap to use, it may be advisable to test each patient separately and educate him/her regarding the soaps/cleansers less likely to cause irritation. The limitations of the study was that it was single blind and non-randomized as all the 14 soap solutions were applied on 15 volunteers in the first panel and subsequently all the 17 soap solutions were applied on eight volunteers in the second panel. However, we could compare the irritant potential of 31 cleansers. The results of 24-h patch testing of 31 soaps/cleansers in the Indian market in two panels of 14 and 17 soaps/cleansers on 15 and eight volunteers, respectively, are presented.

  2. A review of current issues underlying colon cleansing before colonoscopy

    PubMed Central

    Hookey, Lawrence C; Vanner, Stephen

    2007-01-01

    The present review examines four current issues related to the efficacy, patient tolerance and safety of the following bowel cleansing agents: oral sodium phosphate (NaP), polyethylene glycol (PEG) and magnesium citrate (Pico-Salax, Ferring Pharmaceuticals Inc, Canada), an agent recently made available in Canada. MedLine and PubMed databases were systematically searched to identify studies related to the efficacy of altered PEG solutions combined with adjunct treatments; the efficacy, tolerability and safety of Pico-Salax; the association between nephrocalcinosis, and chronic renal failure and oral NaP use; and the role of diet. Although lower volume PEG solutions combined with adjuvant agents were generally associated with better patient tolerance, their efficacy was varied and interpretation of this end point is complicated by study design issues. There are very few reported studies of Pico-Salax, and as a result, there are insufficient data to draw conclusions about the efficacy of this agent. The available data suggest that Pico-Salax may be better tolerated by patients, than oral NaP and PEG solutions. There is a paucity of hemodynamic monitoring data pre- and postadministration, but the available data suggests that this small-volume osmotic agent could cause subclinical contraction of the intravascular space. Recent case reports suggest an association between nephrocalcinosis and oral NaP ingestion, but to date, these reports have been confined to a single centre. Preliminary studies suggest that this is not a widespread problem, but more studies are needed. There are only a few studies examining diet and patient tolerability, but they do suggest that diet may be liberalized with some cleansing regimens to enhance tolerability without decreasing efficacy. The present review highlights current controversies and advances in colon cleansing before colonoscopy, and also identifies areas for further study. PMID:17299615

  3. Evaluating cleansing effects on trace elements and stable isotope values in feathers of oiled birds.

    PubMed

    Valladares, Sonia; Moreno, Roćio; Jover, Lluis; Sanpera, Carola

    2010-01-01

    Feathers of seabirds are widely used as a nondestructive tissue for pollution monitoring of trace elements, as well as convenient samples for trophic ecology studies by means of stable isotope analysis (SIA). Nevertheless, feathers can be occasionally impregnated with oil from deliberate ship discharges and from massive oil spill accidents. The feather structure makes them effective traps for particles and are subject to external contamination. It is unknown to what extent the oil adhered to feathers can change trace element concentrations or stable isotope signatures. This study has two primary objectives: (1) to assess if there are differences between trace element concentrations and stable isotope signatures of oiled and clean feathers, and (2) to determine if the cleansing of oiled feathers using commonly applied techniques such as sodium hydroxide (NaOH) washes in combination with an organic solvent (hexane) is more effective than using NaOH alone. In order to do this, we analysed trace elements (Se, Hg, Pb, Cu and Zn) and stable isotopes (delta(13)C and delta(15)N) of individual feathers of yellow-legged gulls (Larus michahellis) which were affected by the 2002 Prestige oil spill in Galicia (NW Spain). Two sets of feathers were analysed, one group were oil-free (Control group) and the other had oil adhered to its surface (Oiled group). We expected to find differences between control and oiled feathers when cleaning exclusively with NaOH and no differences when using hexane. Our results did not show significant differences between Control and Oiled groups as a consequence of the cleansing method used. Unexpectedly, the additional cleansing with hexane resulted in decreasing selenium concentrations and increasing zinc and delta(15)N values in all groups of feathers.

  4. Bowel preparations for colonoscopy: an RCT.

    PubMed

    Di Nardo, Giovanni; Aloi, Marina; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Civitelli, Fortunata; Nuti, Federica; Ziparo, Chiara; Pession, Andrea; Lima, Mario; La Torre, Giuseppe; Oliva, Salvatore

    2014-08-01

    The ideal preparation regimen for pediatric colonoscopy remains elusive, and available preparations continue to represent a challenge for children. The aim of this study was to compare the efficacy, safety, tolerability, and acceptance of 4 methods of bowel cleansing before colonoscopy in children. This randomized, investigator-blinded, noninferiority trial enrolled all children aged 2 to 18 years undergoing elective colonoscopy in a referral center for pediatric gastroenterology. Patients were randomly assigned to receive polyethylene glycol (PEG) 4000 with simethicon (PEG-ELS group) or PEG-4000 with citrates and simethicone plus bisacodyl (PEG-CS+Bisacodyl group), or PEG 3350 with ascorbic acid (PEG-Asc group), or sodium picosulfate plus magnesium oxide and citric acid (NaPico+MgCit group). Bowel cleansing was evaluated according to the Boston Bowel Preparation Scale. The primary end point was overall colon cleansing. Tolerability, acceptability, and compliance were also evaluated. Two hundred ninety-nine patients were randomly allocated to the 4 groups. In the per-protocol analysis, PEG-CS+Bisacodyl, PEG-Asc, and NaPico+MgCit were noninferior to PEG-ELS in bowel-cleansing efficacy of both the whole colon (P = .910) and colonic segments. No serious adverse events occurred in any group. Rates of tolerability, acceptability, and compliance were significantly higher in the NaPico+MgCit group. Low-volume PEG preparations (PEG-CS+Bisacodyl, PEG-Asc) and NaPico+MgCit are noninferior to PEG-ELS in children, representing an attractive alternative to high-volume regimens in clinical practice. Because of the higher tolerability and acceptability profile, NaPico+MgCit would appear as the most suitable regimen for bowel preparation in children. Copyright © 2014 by the American Academy of Pediatrics.

  5. Comparison of a new sulfate-free polyethylene glycol electrolyte lavage solution versus a standard solution for colonoscopy cleansing.

    PubMed

    DiPalma, J A; Marshall, J B

    1990-01-01

    A new sulfate-free polyethylene glycol electrolyte lavage solution (SF-ELS) for colonoscopy was formulated to taste better and have less net water and electrolyte secretion and absorption than a standard polyethylene glycolelectrolyte lavage solution (PEG-ELS). At two centers, 157 patients were prospectively randomized to receive SF-ELS or PEG-ELS to assess adequacy of preparation, patient tolerance, weight changes, and various hematologic and biochemical parameters. Physician assessment of colon cleansing showed no difference between those patients receiving SF-ELS (N = 74) or PEG-ELS (N = 78). Eighty-two percent of all preps were found to be "clinically acceptable." Subjects receiving SF-ELS had significantly less fullness and cramps, while PEG-ELS subjects reported less nausea. There was no difference between groups for vomiting, overall discomfort, or willingness to repeat the preparation received. Eighty percent of all patients would repeat the randomized cleansing methods. There were no clinically significant changes in weight or assessed laboratory parameters, with the exception of potassium where PEG-ELS patients had an mean decrease of 0.22 mEq/liter vs. 0.01 mEq/liter for SF-ELS (p less than or equal to 0.01). Patient taste questionnaires in those patients expressing a preference showed a preference for SF-ELS (76.6%) over PEG-ELS (23.4%) (p less than or equal to 0.001). Thirty-two (22.5%) of total respondents indicated no preference. We conclude that SF-ELS when compared with PEG-ELS is similarly a safe and effective method of colon cleansing for colonoscopy that is well tolerated. Patients prefer the taste of the new solution.

  6. Langley Air Force Base Marina Repair Environmental Assessment

    DTIC Science & Technology

    2004-08-16

    of human perception for extended periods of time; cosmetic or structural damage could occur to buildings. Table 3-8 presents the minimum distance at...Hazardous Waste Storage Areas (HWSA) where they are stored until disposal is economically practicable or before 90 days has expired , whichever comes...Shop, where paintss paint thinners, ·paint mixing, and cleansing of paint equipment took place between 1950 md 1991. The other is the gasoline storage

  7. Chicago's urban forest ecosystem: results of the Chicago Urban Forest Climate Project

    Treesearch

    Gregory E. McPherson; David J. Nowak; Rowan A. Rowntree

    1994-01-01

    Results of the 3-year Chicago Urban Forest Climate Project indicate that there are an estimated 50.8 million trees in the Chicago area of Cook and DuPage Counties; 66 percent of these trees rated in good or excellent condition. During 1991, trees in the Chicago area removed an estimated 6,145 tons of air pollutants, providing air cleansing valued at $9.2 million...

  8. Use of Powder PEG-3350 as a Sole Bowel Preparation: Clinical Case Series of 245 Patients.

    PubMed

    Arora, Manish; Okolo, Patrick I

    2008-07-01

    To assess the efficacy of low-volume powder polyethylene glycol (PEG)-3350 as a sole bowel preparation for colonoscopy. This case series examined 245 consecutive patients (a mixture of inpatients and outpatients undergoing screening colonoscopy) at a hospital endoscopy center over a 2-year period. The patients received powder PEG-3350 in the amount of 204 g dissolved in 32 oz of water and taken in 3 divided doses 1 hour apart with 8 oz of water in between each dose. Colon preparation scores (CPS) were used to assess the quality of colon cleansing. The results obtained from the 245 patients were collated and compared to those of patients receiving sodium phosphate, the historical control. The mean CPS was calculated to be 3.43, with a standard deviation of 1.12. Of the 245 patients, 92 were scored with a grade of 4, and 5 patients had incomplete colonoscopies secondary to failure of bowel preparation (CPS=0). Among the remaining patients, 22 and 26 were graded as poor (CPS=1) or fair (CPS=2) bowel preparations, respectively. The low-volume powder PEG-3350 formula used in our case series showed effective colon cleansing and may be considered for use as a sole bowel preparation.

  9. Use of Powder PEG-3350 as a Sole Bowel Preparation

    PubMed Central

    Arora, Manish

    2008-01-01

    Objective: To assess the efficacy of low-volume powder polyethylene glycol (PEG)-3350 as a sole bowel preparation for colonoscopy. Methods: This case series examined 245 consecutive patients (a mixture of inpatients and outpatients undergoing screening colonoscopy) at a hospital endoscopy center over a 2-year period. The patients received powder PEG-3350 in the amount of 204 g dissolved in 32 oz of water and taken in 3 divided doses 1 hour apart with 8 oz of water in between each dose. Colon preparation scores (CPS) were used to assess the quality of colon cleansing. The results obtained from the 245 patients were collated and compared to those of patients receiving sodium phosphate, the historical control. Results: The mean CPS was calculated to be 3.43, with a standard deviation of 1.12. Of the 245 patients, 92 were scored with a grade of 4, and 5 patients had incomplete colonoscopies secondary to failure of bowel preparation (CPS=0). Among the remaining patients, 22 and 26 were graded as poor (CPS=1) or fair (CPS=2) bowel preparations, respectively. Conclusion: The low-volume powder PEG-3350 formula used in our case series showed effective colon cleansing and may be considered for use as a sole bowel preparation. PMID:21960925

  10. Two-stage Electron Acceleration by 3D Collisionless Guide-field Magnetic Reconnection

    NASA Astrophysics Data System (ADS)

    Buechner, J.; Munoz, P.

    2017-12-01

    We discuss a two-stage process of electron acceleration near X-lines of 3D collisionless guide-field magnetic reconnection. Non-relativistic electrons are first pre-accelerated by magnetic-field-aligned (parallel) electric fields. At the nonlinear stage of 3D guide-field magnetic reconnection electric and magnetic fields become filamentary structured due to streaming instabilities. This causes an additional curvature-driven electron acceleration in the guide-field direction. The resulting spectrum of the accelerated electrons follows a power law.

  11. Comparative study of sorption and solubility of heat-cure and self-cure acrylic resins in different solutions.

    PubMed

    Saini, Rajesh; Kotian, Ravindra; Madhyastha, Prashanthi; Srikant, N

    2016-01-01

    The objective of this study was to compare the sorption and solubility of heat-cure and self-cure acrylic resins in different solutions. One heat-cure acrylic resin (Trevalon) and one self-cure acrylic resin (Rapid Repair) were studied. Five groups of square-shaped specimens (20 mm × 20 mm × 2 mm) were prepared for each acrylic resin and then immersed in five solutions: distilled water, artificial saliva, denture cleansing solution, distilled water, and denture cleaning solution for 12 h alternatively, artificial saliva and denture cleaning solution for 12 h alternatively at 37 ± 2°C, and tested sorption and solubility by weight gain/loss method, respectively, after 1, 6, and 11 weeks. The data were analyzed by one-way analysis of variance followed by post hoc Tukey's test. Water sorption mean values varied from 17.5 ± 0.88 to 27.25 ± 1.04 μg/mm 3 for heat cure and from 12.75 ± 0.55 to 19.75 ± 1.04 μg/mm 3 for self-cure in the different solutions after different interval periods of 1, 6, and 11 weeks. These values were statistically significant (P< 0.001). Water solubility mean values varied from 0.25 ± 0.55 to 1.5 ± 0.55 μg/mm 3 for heat cure and from 1.5 ± 0.55 to 6.5 ± 0.55 μg/mm 3 for self-cure in the different solutions after different interval periods of 1, 6, and 11 weeks. These values were statistically not significant (P > 0.05). There was no linear correlation between sorption and solubility values. Overall, analysis of results showed the maximum sorption value in denture cleansing solution followed by alternative soaking in distilled water and artificial saliva. Least sorption was observed with artificial saliva followed by distilled water. Both heat-cure and self-cure acrylic resins showed varying water sorption and solubility. The results of both water sorption and solubility showed compliance with the International Standards Organization specification. No correlation was found between water sorption and solubility. Artificial saliva solution is a better storage medium than distilled water and denture cleansing solution for both heat-cure and self-cure acrylic resins.

  12. Lavender fragrance cleansing gel effects on relaxation.

    PubMed

    Field, Tiffany; Diego, Miguel; Hernandez-Reif, Maria; Cisneros, Wendy; Feijo, Larissa; Vera, Yanexy; Gil, Karla; Grina, Diana; Claire He, Qing

    2005-02-01

    Alertness, mood, and math computations were assessed in 11 healthy adults who sniffed a cosmetic cleansing gel with lavender floral blend aroma, developed to be relaxing using Mood Mapping. EEG patterns and heart rate were also recorded before, during, and after the aroma session. The lavender fragrance blend had a significant transient effect of improving mood, making people feel more relaxed, and performing the math computation faster. The self-report and physiological data are consistent with relaxation profiles during other sensory stimuli such as massage and music, as reported in the literature. The data suggest that a specific cosmetic fragrance can have a significant role in enhancing relaxation.

  13. Caged ATP - an internal calibration method for ATP bioluminescence assays.

    PubMed

    Calvert, R M; Hopkins, H C; Reilly, M J; Forsythe, S J

    2000-03-01

    ATP bioluminescence, based on the firefly luciferase system, is used for the rapid determination of hygienic practices in the food industry. This study has demonstrated the use of caged ATP as an internal ATP standard and quantified the effects of industrial cleansing solutions, alcoholic beverages and pH on firefly luciferase activity. The light signal was quenched 6-47% by five cleansing solutions at standard working concentrations. Ethanol at 1% (v/v) inhibited bioluminescence by 15% (w/v) whereas concentrations above 4% enhanced the light output. The light signal was quenched by 20-25% at pH values below pH 4 and above pH 10.

  14. New Eye Cleansing Product Improves Makeup-Related Ocular Problems.

    PubMed

    Okura, Masako; Kawashima, Motoko; Katagiri, Mikiyuki; Shirasawa, Takuji; Tsubota, Kazuo

    2015-01-01

    Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.

  15. Calixarene cleansing formulation for uranium skin contamination.

    PubMed

    Phan, Guillaume; Semili, Naïma; Bouvier-Capely, Céline; Landon, Géraldine; Mekhloufi, Ghozlene; Huang, Nicolas; Rebière, François; Agarande, Michelle; Fattal, Elias

    2013-10-01

    An oil-in-water cleansing emulsion containing calixarene molecule, an actinide specific chelating agent, was formulated in order to improve the decontamination of uranium from the skin. Commonly commercialized cosmetic ingredients such as surfactants, mineral oil, or viscosifying agents were used in preparing the calixarene emulsion. The formulation was characterized in terms of size and apparent viscosity measurements and then was tested for its ability to limit uranyl ion permeation through excoriated pig-ear skin explants in 24-h penetration studies. Calixarene emulsion effectiveness was compared with two other reference treatments consisting of DTPA and EHBP solutions. Application of calixarene emulsion induced the highest decontamination effect with an 87% decrease in uranium diffusion flux. By contrast, EHBP and DTPA solutions only allowed a 50% and 55% reduction of uranium permeation, respectively, and had the same effect as a simple dilution of the contamination by pure water. Uranium diffusion decrease was attributed to uranyl ion-specific chelation by calixarene within the formulation, since no significant effect was obtained after application of the same emulsion without calixarene. Thus, calixarene cleansing emulsion could be considered as a promising treatment in case of accidental contamination of the skin by highly diffusible uranium compounds.

  16. New Eye Cleansing Product Improves Makeup-Related Ocular Problems

    PubMed Central

    Okura, Masako; Kawashima, Motoko

    2015-01-01

    Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms. PMID:26347812

  17. The use of recombinant omega interferon therapy in canine atopic dermatitis: a double-blind controlled study.

    PubMed

    Carlotti, Didier Noël; Boulet, Marc; Ducret, Joël; Machicote, Gustavo; Jasmin, Pierre; Rème, Christophe A; Albouy, Maxime

    2009-10-01

    This double-blind controlled study assessed whether reduced doses of omega interferon (rFeIFN-omega) (Virbagen Omega) could improve the clinical signs of canine atopic dermatitis (CAD) over a 6-month period, in comparison with cyclosporin. Thirty-one dogs diagnosed with CAD were entered in the study. Complicating infections were treated prior to entry. Dogs received 10 injections of rFeIFN-omega (1-5 million units according to bodyweight) or placebo over 6 months, and placebo capsules or cyclosporin (5 mg/kg) once daily for 2 months and then twice weekly for 4 months in groups 1 and 2 respectively. Flea control, non-medicated shampooing and ear cleansing were performed regularly. If a bacterial infection or Malassezia overgrowth developed, it was treated with oral cephalexin or with 3% chlorhexidine shampoo respectively. Oral prednisolone was used before day 90 to relieve pruritus when required for humane reasons (1 mg/kg once daily for 7 days). The CADESI-03 and a pruritus index were evaluated on day (D) 0, D14, D35, D56, D90, D120 and D180. No significant difference was detected between the groups for the time courses of lesions or pruritus over 6 months. On D90, the proportions of dogs with > or =50% improvement of pruritus and lesion scores were 56% and 72% respectively with interferon, 75% and 75% respectively with cyclosporin. Five dogs from group 1 and two dogs from group 2 were withdrawn from the study for treatment failure. Both products were well tolerated. Treatment with rfeIFN-omega at low doses may help for the long-term management of CAD.

  18. Synthesis of an A-D-A type of molecule used as electron acceptor for improving charge transfer in organic solar cells

    NASA Astrophysics Data System (ADS)

    Zhang, Chao-Zhi; Gu, Shu-Duo; Shen, Dan; Yuan, Yang; Zhang, Mingdao

    2016-08-01

    Electron-accepting molecules play an important role in developing organic solar cells. A new type of A-D-A molecule, 3,6-di([7-(5-bromothiophen-2-yl)-1,5,2,4,6,8-dithiotetrazocin-3-yl]thiophen-2-yl)-9-(2-ethylhexyl)carbazole, was synthesized. The lowest unoccupied molecular orbital (LUMO) and highest occupied molecular orbital (HOMO) energy levels are -3.55 and -5.85 eV, respectively. Therefore, the A-D-A type of compound could be used as electron acceptor for fabricating organic solar cell with a high open circuit voltage. Gibbs free energy (-49.2 kJ/mol) reveals that the process of A-D-A acceptor accepting an electron from poly(3-hexylthiophene) at excited state is spontaneous. The value of entropy (118 J/mol) in the process of an electron transferring from P3HT to the A-D-A acceptor at organic interface suggests that electrons generated from separation of electron-hole pairs at donor/acceptor interface would be delocalized efficiently. Therefore, the A-D-A molecule would be a potential acceptor for efficient organic BHJ solar cells.

  19. Critical thickness for the two-dimensional electron gas in LaTiO3/SrTiO3 superlattices

    NASA Astrophysics Data System (ADS)

    You, Jeong Ho; Lee, Jun Hee

    2013-10-01

    Transport dimensionality of Ti d electrons in (LaTiO3)1/(SrTiO3)N superlattices has been investigated using density functional theory with local spin-density approximation + U method. Different spatial distribution patterns have been found between Ti t2g orbital electrons. The dxy orbital electrons are highly localized near interfaces due to the potentials by positively charged LaO layers, while the degenerate dyz and dxz orbital electrons are more distributed inside SrTiO3 insulators. For N ≥ 3 unit cells (u.c.), the Ti dxy densities of state exhibit the staircaselike increments, which appear at the same energy levels as the dxy flat bands along the Γ-Z direction in band structures. The kz-independent discrete energy levels indicate that the electrons in dxy flat bands are two-dimensional electron gases (2DEGs) which can transport along interfaces, but they cannot transport perpendicularly to interfaces due to the confinements in the potential wells by LaO layers. Unlike the dxy orbital electrons, the dyz and dxz orbital electrons have three-dimensional (3D) transport characteristics, regardless of SrTiO3 thicknesses. The 2DEG formation by dxy orbital electrons, when N ≥ 3 u.c., indicates the existence of critical SrTiO3 thickness where the electron transport dimensionality starts to change from 3D to 2D in (LaTiO3)1/(SrTiO3)N superlattices.

  20. Local 3d Electronic Structures of Co-Based Complexes with Medicinal Molecules Probed by Soft X-ray Absorption

    NASA Astrophysics Data System (ADS)

    Yamagami, Kohei; Fujiwara, Hidenori; Imada, Shin; Kadono, Toshiharu; Yamanaka, Keisuke; Muro, Takayuki; Tanaka, Arata; Itai, Takuma; Yoshinari, Nobuto; Konno, Takumi; Sekiyama, Akira

    2017-07-01

    We have examined the local 3d electronic structures of Co-Au multinuclear complexes with the medicinal molecules d-penicillaminate (d-pen) [Co{Au(PPh3)(d-pen)}2]ClO4 and [Co3{Au3(tdme)(d-pen)3}2] by Co L2,3-edge soft X-ray absorption (XAS) spectroscopy, where PPh3 denotes triphenylphosphine and tdme stands for 1,1,1-tris[(diphenylphosphino)methyl]ethane. The Co L2,3-edge XAS spectra indicate the localized ionic 3d electronic states in both materials. The experimental spectra are well explained by spectral simulation for a localized Co ion under ligand fields with the full multiplet theory, which verifies that the ions are in the low-spin Co3+ state in the former compound and in the high-spin Co2+ state in the latter.

  1. Electron coherent diffraction tomography of a nanocrystal

    NASA Astrophysics Data System (ADS)

    Dronyak, Roman; Liang, Keng S.; Tsai, Jin-Sheng; Stetsko, Yuri P.; Lee, Ting-Kuo; Chen, Fu-Rong

    2010-05-01

    Coherent diffractive imaging (CDI) with electron or x-ray sources is a promising technique for investigating the structure of nanoparticles down to the atomic scale. In electron CDI, a two-dimensional reconstruction is demonstrated using highly coherent illumination from a field-emission gun as a source of electrons. In a three-dimensional (3D) electron CDI, we experimentally determine the morphology of a single MgO nanocrystal using the Bragg diffraction geometry. An iterative algorithm is applied to invert the 3D diffraction pattern about a (200) reflection of the nanoparticle measured at an angular range of 1.8°. The results reveal a 3D image of the sample at ˜8 nm resolution, and agree with a simulation. Our work demonstrates an alternative approach to obtain the 3D structure of nanocrystals with an electron microscope.

  2. Correlation between valence electronic structure and magnetic properties in RCo5 (R = rare earth) intermetallic compound

    NASA Astrophysics Data System (ADS)

    Zhi-Qin, Xue; Yong-Quan, Guo

    2016-06-01

    The magnetisms of RCo5 (R = rare earth) intermetallics are systematically studied with the empirical electron theory of solids and molecules (EET). The theoretical moments and Curie temperatures agree well with experimental ones. The calculated results show strong correlations between the valence electronic structure and the magnetic properties in RCo5 intermetallic compounds. The moments of RCo5 intermetallics originate mainly from the 3d electrons of Co atoms and 4f electrons of rare earth, and the s electrons also affect the magnetic moments by the hybridization of d and s electrons. It is found that moment of Co atom at 2c site is higher than that at 3g site due to the fact that the bonding effect between R and Co is associated with an electron transformation from 3d electrons into covalence electrons. In the heavy rare-earth-based RCo5 intermetallics, the contribution to magnetic moment originates from the 3d and 4f electrons. The covalence electrons and lattice electrons also affect the Curie temperature, which is proportional to the average moment along the various bonds. Project supported by the National Natural Science Foundation of China (Grant No. 11274110).

  3. Electron density determination and bonding in tetragonal binary intermetallics by convergent beam electron diffraction

    NASA Astrophysics Data System (ADS)

    Sang, Xiahan

    Intermetallics offer unique property combinations often superior to those of more conventional solid solution alloys of identical composition. Understanding of bonding in intermetallics would greatly accelerate development of intermetallics for advanced and high performance engineering applications. Tetragonal intermetallics L10 ordered TiAl, FePd and FePt are used as model systems to experimentally measure their electron densities using quantitative convergent beam electron diffraction (QCBED) method and then compare details of the 3d-4d (FePd) and 3d-5d (FePt) electron interactions to elucidate their role on properties of the respective ferromagnetic L10-ordered intermetallics FePd and FePt. A new multi-beam off-zone axis condition QCBED method has been developed to increase sensitivity of CBED patterns to change of structure factors and the anisotropic Debye-Waller (DW) factors. Unprecedented accuracy and precision in structure and DW factor measurements has been achieved by acquiring CBED patterns using beam-sample geometry that ensures strong dynamical interaction between the fast electrons and the periodic potential in the crystalline samples. This experimental method has been successfully applied to diamond cubic Si, and chemically ordered B2 cubic NiAl, tetragonal L10 ordered TiAl and FePd. The accurate and precise experimental DW and structure factors for L10 TiAl and FePd allow direct evaluation of computer calculations using the current state of the art density functional theory (DFT) based electron structure modeling. The experimental electron density difference map of L1 0 TiAl shows that the DFT calculations describe bonding to a sufficient accuracy for s- and p- electrons interaction, e. g., the Al-layer. However, it indicate significant quantitative differences to the experimental measurements for the 3d-3d interactions of the Ti atoms, e.g. in the Ti layers. The DFT calculations for L10 FePd also show that the current DFT approximations insufficiently describe the interaction between Fe-Fe (3d-3d), Fe-Pd (3d-4d) and Pd-Pd (4d-4d) electrons, which indicates the necessity to evaluate applicability of different DFT approximations, and also provides experimental data for the development of new DFT approximation that better describes transition metal based intermetallic systems.

  4. Electron attachment to DNA single strands: gas phase and aqueous solution.

    PubMed

    Gu, Jiande; Xie, Yaoming; Schaefer, Henry F

    2007-01-01

    The 2'-deoxyguanosine-3',5'-diphosphate, 2'-deoxyadenosine-3',5'-diphosphate, 2'-deoxycytidine-3',5'-diphosphate and 2'-deoxythymidine-3',5'-diphosphate systems are the smallest units of a DNA single strand. Exploring these comprehensive subunits with reliable density functional methods enables one to approach reasonable predictions of the properties of DNA single strands. With these models, DNA single strands are found to have a strong tendency to capture low-energy electrons. The vertical attachment energies (VEAs) predicted for 3',5'-dTDP (0.17 eV) and 3',5'-dGDP (0.14 eV) indicate that both the thymine-rich and the guanine-rich DNA single strands have the ability to capture electrons. The adiabatic electron affinities (AEAs) of the nucleotides considered here range from 0.22 to 0.52 eV and follow the order 3',5'-dTDP > 3',5'-dCDP > 3',5'-dGDP > 3',5'-dADP. A substantial increase in the AEA is observed compared to that of the corresponding nucleic acid bases and the corresponding nucleosides. Furthermore, aqueous solution simulations dramatically increase the electron attracting properties of the DNA single strands. The present investigation illustrates that in the gas phase, the excess electron is situated both on the nucleobase and on the phosphate moiety for DNA single strands. However, the distribution of the extra negative charge is uneven. The attached electron favors the base moiety for the pyrimidine, while it prefers the 3'-phosphate subunit for the purine DNA single strands. In contrast, the attached electron is tightly bound to the base fragment for the cytidine, thymidine and adenosine nucleotides, while it almost exclusively resides in the vicinity of the 3'-phosphate group for the guanosine nucleotides due to the solvent effects. The comparatively low vertical detachment energies (VDEs) predicted for 3',5'-dADP(-) (0.26 eV) and 3',5'-dGDP(-) (0.32 eV) indicate that electron detachment might compete with reactions having high activation barriers such as glycosidic bond breakage. However, the radical anions of the pyrimidine nucleotides with high VDE are expected to be electronically stable. Thus the base-centered radical anions of the pyrimidine nucleotides might be the possible intermediates for DNA single-strand breakage.

  5. Importance of conduction electron correlation in a Kondo lattice, Ce₂CoSi₃.

    PubMed

    Patil, Swapnil; Pandey, Sudhir K; Medicherla, V R R; Singh, R S; Bindu, R; Sampathkumaran, E V; Maiti, Kalobaran

    2010-06-30

    Kondo systems are usually described by the interaction of the correlation induced local moments with the highly itinerant conduction electrons. Here, we study the role of electron correlations among conduction electrons in the electronic structure of a Kondo lattice compound, Ce₂CoSi₃, using high resolution photoemission spectroscopy and ab initio band structure calculations, where Co 3d electrons contribute in the conduction band. High energy resolution employed in the measurements helped to reveal the signatures of Ce 4f states derived Kondo resonance features at the Fermi level and the dominance of Co 3d contributions at higher binding energies in the conduction band. The lineshape of the experimental Co 3d band is found to be significantly different from that obtained from the band structure calculations within the local density approximations, LDA. Consideration of electron-electron Coulomb repulsion, U, among Co 3d electrons within the LDA + U method leads to a better representation of experimental results. The signature of an electron correlation induced satellite feature is also observed in the Co 2p core level spectrum. These results clearly demonstrate the importance of the electron correlation among conduction electrons in deriving the microscopic description of such Kondo systems.

  6. [An experimental evaluation of the efficacy of 4 types of detergents for 3 types of dyes to which workers in color-printing plants are exposed].

    PubMed

    Terzaghi, G F; Settimi, L; Peverelli, C; Sevosi, L; Duca, P G

    1996-01-01

    The efficacy of 4 commercial cleansing products was tested with 3 colouring agents widely used in the dyeing industry in a randomised double blind trail involving 8 workers each time. A between-detergents statistically significant difference was observed; the interaction (detergents x colouring agents) was significant. The efficacy of type A detergent was higher for type I-III dyers, while the efficacy of type C detergent, which widely used was lowest.

  7. Two-electron oxidation of deoxyguanosine by a Ru(III) complex without involving oxygen molecules through disproportionation.

    PubMed

    Choi, Sunhee; Ryu, DaWeon; DellaRocca, Joseph G; Wolf, Matthew W; Bogart, Justin A

    2011-07-18

    Among the many mechanisms for the oxidation of guanine derivatives (G) assisted by transition metals, Ru(III) and Pt(IV) metal ions share basically the same principle. Both Ru(III)- and Pt(IV)-bound G have highly positively polarized C8-H's that are susceptible to deprotonation by OH(-), and both undergo two-electron redox reactions. The main difference is that, unlike Pt(IV), Ru(III) is thought to require O(2) to undergo such a reaction. In this study, however, we report that [Ru(III)(NH(3))(5)(dGuo)] (dGuo = deoxyguanosine) yields cyclic-5'-O-C8-dGuo (a two-electron G oxidized product, cyclic-dGuo) without O(2). In the presence of O(2), 8-oxo-dGuo and cyclic-dGuo were observed. Both [Ru(II)(NH(3))(5)(dGuo)] and cyclic-dGuo were produced from [Ru(III)(NH(3))(5)(dGuo)] accelerated by [OH(-)]. We propose that [Ru(III)(NH(3))(5)(dGuo)] disproportionates to [Ru(II)(NH(3))(5)(dGuo)] and [Ru(IV)(NH(3))(4)(NH(2)(-))(dGuo)], followed by a 5'-OH attack on C8 in [Ru(IV)(NH(3))(4)(NH(2)(-))(dGuo)] to initiate an intramolecular two-electron transfer from dGuo to Ru(IV), generating cyclic-dGuo and Ru(II) without involving O(2).

  8. Electron Tomography: A Three-Dimensional Analytic Tool for Hard and Soft Materials Research

    DOE PAGES

    Ercius, Peter; Alaidi, Osama; Rames, Matthew J.; ...

    2015-06-18

    Three-dimensional (3D) structural analysis is essential to understand the relationship between the structure and function of an object. Many analytical techniques, such as X-ray diffraction, neutron spectroscopy, and electron microscopy imaging, are used to provide structural information. Transmission electron microscopy (TEM), one of the most popular analytic tools, has been widely used for structural analysis in both physical and biological sciences for many decades, in which 3D objects are projected into two-dimensional (2D) images. In many cases, 2D-projection images are insufficient to understand the relationship between the 3D structure and the function of nanoscale objects. Electron tomography (ET) is amore » technique that retrieves 3D structural information from a tilt series of 2D projections, and is gradually becoming a mature technology with sub-nanometer resolution. Distinct methods to overcome sample-based limitations have been separately developed in both physical and biological science, although they share some basic concepts of ET. Here, this review discusses the common basis for 3D characterization, and specifies difficulties and solutions regarding both hard and soft materials research. It is hoped that novel solutions based on current state-of-the-art techniques for advanced applications in hybrid matter systems can be motivated. Electron tomography produces quantitative 3D reconstructions for biological and physical sciences from sets of 2D projections acquired at different tilting angles in a transmission electron microscope. Finally, state-of-the-art techniques capable of producing 3D representations such as Pt-Pd core-shell nanoparticles and IgG1 antibody molecules are reviewed.« less

  9. Occupational contact dermatitis caused by D-limonene.

    PubMed

    Pesonen, Maria; Suomela, Sari; Kuuliala, Outi; Henriks-Eckerman, Maj-Len; Aalto-Korte, Kristiina

    2014-11-01

    Limonene is widely used as a fragrance substance and solvent in cleansing products. Oxidized limonene is a frequent contact allergen among consumers of cosmetics, personal care products, and scented household cleaning products. Less is known about the sources of occupational exposure and occupational contact dermatitis caused by limonene. To report 14 patients with occupational contact allergy to limonene. The patients were examined in 2008-2013. An in-house preparation of oxidized limonene was patch tested as 3% and 5% in petrolatum from 2008 to August 2010, and after this as 3%, 1% and 0.3% pet. From 2012 onwards, a commercial test substance of limonene hydroperoxides was also used. We assessed the patients' occupational and domestic exposure to limonene. Occupational limonene allergy was observed in workers who used limonene-containing machine-cleaning detergents and hand cleansers, and in workers who used limonene-containing surface cleaners and dishwashing liquids similar to those used by consumers. In 3 cases, the occupational limonene allergy resulted from work-related use of limonene-containing, leave-on cosmetic products. Limonene is a frequent occupational sensitizer in hand cleansers and cleaning products. Occupational limonene contact allergy may also be caused by exposure to cosmetic products scented with limonene. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. [Preparation for colonoscopy: types of scales and cleaning products].

    PubMed

    Lorenzo-Zúñiga, Vicente; Moreno-de-Vega, Vicente; Boix, Jaume

    2012-08-01

    Adequate bowel preparation is essential before a colonoscopy, allowing us to make a proper examination of the entire mucosa. The ideal method of colon cleansing should be fast, safe, and get a proper cleaning with minimal discomfort for the patient. Today we have a wide variety of colon cleansing products, information sometimes becomes confused. A good colon preparation depends partly on correct choice of the same, but also upon dietary restriction. Knowledge of all these products, with their advantages and limitations, we can make a better selection for each patient, and although the efficacy is comparable, is the experience of the browser, patient preferences, and the degree of compliance with the instructions preparation, which greatly influence the results.

  11. Blanch Resistant and Thermal Barrier NiAl Coating Systems for Advanced Copper Alloys

    NASA Technical Reports Server (NTRS)

    Raj, Sai V. (Inventor)

    2005-01-01

    A method of forming an environmental resistant thermal barrier coating on a copper alloy is disclosed. The steps include cleansing a surface of a copper alloy, depositing a bond coat on the cleansed surface of the copper alloy, depositing a NiAl top coat on the bond coat and consolidating the bond coat and the NiAl top coat to form the thermal barrier coating. The bond coat may be a nickel layer or a layer composed of at least one of copper and chromium-copper alloy and either the bond coat or the NiAl top coat or both may be deposited using a low pressure or vacuum plasma spray.

  12. Individual change after genocide in Bosnian survivors of "ethnic cleansing": assessing personality dysfunction.

    PubMed

    Weine, S M; Becker, D F; Vojvoda, D; Hodzic, E; Sawyer, M; Hyman, L; Laub, D; McGlashan, T H

    1998-01-01

    The authors used the SCID-DES (disorders of extreme stress) instrument to assess for personality change in Bosnian survivors of "ethnic cleansing." Twenty four refugees underwent systematic, trauma-focused, research assessments, including the SCID-DES interview. Overall, this group of Bosnian survivors had been severely traumatized as a result of the Serbian nationalists' genocide. However, no subject met diagnostic criteria for DES. The SCID-DES yields far lower rates of trauma-related personality change in Bosnian survivors of genocide than in adult survivors of prolonged early life traumas. Therefore, the DES construct may have better application to prolonged, interpersonal, early life traumas than to the prolonged, communal traumas of genocide.

  13. Incipient 2D Mott insulators in extreme high electron density, ultra-thin GdTiO3/SrTiO3/GdTiO3 quantum wells

    NASA Astrophysics Data System (ADS)

    Allen, S. James; Ouellette, Daniel G.; Moetakef, Pouya; Cain, Tyler; Chen, Ru; Balents, Leon; Stemmer, Susanne

    2013-03-01

    By reducing the number of SrO planes in a GdTiO3 /SrTiO3/ GdTiO3 quantum well heterostructure, an electron gas with ~ fixed 2D electron density can be driven close to the Mott metal insulator transition - a quantum critical point at ~1 electron per unit cell. A single interface between the Mott insulator GdTiO3 and band insulator SrTiO3 has been shown to introduce ~ 1/2 electron per interface unit cell. Two interfaces produce a quantum well with ~ 7 1014 cm-2 electrons: at the limit of a single SrO layer it may produce a 2D magnetic Mott insulator. We use temperature and frequency dependent (DC - 3eV) conductivity and temperature dependent magneto-transport to understand the relative importance of electron-electron interactions, electron-phonon interactions, and surface roughness scattering as the electron gas is compressed toward the quantum critical point. Terahertz time-domain and FTIR spectroscopies, measure the frequency dependent carrier mass and scattering rate, and the mid-IR polaron absorption as a function of quantum well thickness. At the extreme limit of a single SrO plane, we observe insulating behavior with an optical gap substantially less than that of the surrounding GdTiO3, suggesting a novel 2D Mott insulator. MURI program of the Army Research Office - Grant No. W911-NF-09-1-0398

  14. Shape‐Controlled, Self‐Wrapped Carbon Nanotube 3D Electronics

    PubMed Central

    Wang, Huiliang; Wang, Yanming; Tee, Benjamin C.‐K.; Kim, Kwanpyo; Lopez, Jeffrey; Cai, Wei

    2015-01-01

    The mechanical flexibility and structural softness of ultrathin devices based on organic thin films and low‐dimensional nanomaterials have enabled a wide range of applications including flexible display, artificial skin, and health monitoring devices. However, both living systems and inanimate systems that are encountered in daily lives are all 3D. It is therefore desirable to either create freestanding electronics in a 3D form or to incorporate electronics onto 3D objects. Here, a technique is reported to utilize shape‐memory polymers together with carbon nanotube flexible electronics to achieve this goal. Temperature‐assisted shape control of these freestanding electronics in a programmable manner is demonstrated, with theoretical analysis for understanding the shape evolution. The shape control process can be executed with prepatterned heaters, desirable for 3D shape formation in an enclosed environment. The incorporation of carbon nanotube transistors, gas sensors, temperature sensors, and memory devices that are capable of self‐wrapping onto any irregular shaped‐objects without degradations in device performance is demonstrated. PMID:27980972

  15. The degree of π electron delocalization and the formation of 3D-extensible sandwich structures.

    PubMed

    Wang, Xiang; Wang, Qiang; Yuan, Caixia; Zhao, Xue-Feng; Li, Jia-Jia; Li, Debao; Wu, Yan-Bo; Wang, Xiaotai

    2016-04-28

    DFT B3LYP/6-31G(d) calculations were performed to examine the feasibility of graphene-like C42H18 and starbenzene C6(BeH)6 (SBz) polymers as ligands of 3D-extensible sandwich compounds (3D-ESCs) with uninterrupted sandwich arrays. The results revealed that sandwich compounds with three or more C42H18 ligands were not feasible. The possible reason may be the localization of π electrons on certain C6 hexagons due to π-metal interactions, which makes the whole ligand lose its electronic structure basis (higher degree of π electron delocalization) to maintain the planar structure. For comparison, with the aid of benzene (Bz) molecules, the SBz polymers can be feasible ligands for designing 3D-ESCs because the C-Be interactions in individual SBz are largely ionic, which will deter the π electrons on one C6 ring from connecting to those on neighbouring C6 rings. This means that high degree of π electron delocalization is not necessary for maintaining the planarity of SBz polymers. Such a locally delocalized π electron structure is desirable for the ligands of 3D-ESCs. Remarkably, the formation of a sandwich compound with SBz is thermodynamically more favourable than that found for bis(Bz)chromium. The assembly of 3D-ESCs is largely exothermic, which will facilitate future experimental synthesis. The different variation trends on the HOMO-LUMO gaps in different directions (relative to the sandwich axes) suggest that they can be developed to form directional conductors or semiconductors, which may be useful in the production of electronic devices.

  16. Transplantation of human microbiota into conventional mice durably reshapes the gut microbiota.

    PubMed

    Wrzosek, Laura; Ciocan, Dragos; Borentain, Patrick; Spatz, Madeleine; Puchois, Virginie; Hugot, Cindy; Ferrere, Gladys; Mayeur, Camille; Perlemuter, Gabriel; Cassard, Anne-Marie

    2018-05-01

    Human microbiota-associated (HMA) mice are an important model to study the relationship between liver diseases and intestinal microbiota. We describe a new method to humanize conventional mice based on bowel cleansing with polyethylene glycol followed by fecal microbiota transplantation (FMT) from a human donor. Four successive bowel cleansings were sufficient to empty the intestine and decrease the microbiota by 90%. We then compared four different strategies based on the frequency of FMT over four weeks: (1) twice a week; (2) once a week; (3) two FMTs; (4) one FMT. We were able to transfer human bacteria to mice, irrespective of the strategy used. We detected human bacteria after four weeks, even if only one FMT was performed, but there was a shift of the microbiota over time. FMT twice a week for four weeks was too frequent and perturbed the stability of the newly formed ecosystem. FMT once a week appears to be the best compromise as it allowed engraftment of Faecalibacterium, and a higher diversity of bacteria belonging to the Bacteroidales order. Our easy to establish HMA mouse model could be used as an alternative to classical HMA mice to study the relationship between the liver and the microbiota.

  17. Foot burns: epidemiology and management.

    PubMed

    Hemington-Gorse, S; Pellard, S; Wilson-Jones, N; Potokar, T

    2007-12-01

    This is a retrospective study of the epidemiology and management of isolated foot burns presenting to the Welsh Centre for Burns from January 1998 to December 2002. A total of 289 were treated of which 233 were included in this study. Approximately 40% were in the paediatric age group and the gender distribution varied dramatically for adults and children. In the adult group the male:female ratio was 3.5:1, however in the paediatric group the male:female ratio was more equal (1.6:1). Scald burns (65%) formed the largest group in children and scald (35%) and chemical burns (32%) in adults. Foot burns have a complication rate of 18% and prolonged hospital stay. Complications include hypertrophic scarring, graft loss/delayed healing and wound infection. Although isolated foot burns represent a small body surface area, over half require treatment as in patients to allow for initial aggressive conservative management of elevation and regular wound cleansing to avoid complications. This study suggests a protocol for the initial acute management of foot burns. This protocol states immediate referral of all foot burns to a burn centre, admission of these burns for 24-48 h for elevation, regular wound cleansing with change of dressings and prophylactic antibiotics.

  18. Colon Cleansing: Health or Hype?

    MedlinePlus

    ... Clinical Trials Cancer Genomics Laboratory Cancer Prevention and ... Shot is revolutionizing the conventional medical research approach to rapidly translate findings into patient treatment options ...

  19. The effect of topical treatments for CRS on the sinonasal epithelial barrier.

    PubMed

    Ramezanpour, M; Rayan, A; Smith, J L P; Vreugde, S

    2017-06-01

    Several topical treatments are used in the management of Chronic Rhinosinusitis (CRS), some of which the safety and efficacy has yet to be determined. The purpose of this study was to investigate the effect of commonly used topical treatments on the sinonasal epithelial barrier. Normal saline (0.9% Sodium Chloride), hypertonic saline (3% Sodium Chloride), FESS Sinu-Cleanse Hypertonic, FLO Sinus Care and Budesonide 1 mg/ 2 ml were applied to the apical side of air-liquid interface (ALI) cultures of primary human nasal epithelial cells (HNECs) from CRS patients (n=3) and non-CRS controls (n=3) for 24 hours. Epithelial barrier structure and function was assessed using trans-epithelial electrical resistance (TEER), measuring the passage of Fluorescein Isothiocyanate labelled Dextrans (FITC-Dextrans) and assessing the expression of the tight junction protein Zona Occludens-1 (ZO-1) using immunofluorescence. Toxicity was assessed using a Lactate Dehydrogenase (LDH) assay. Data was analysed using ANOVA, followed by Tukey HSD post hoc test. Hypertonic solution and budesonide significantly increased TEER values in CRS derived HNECs. In contrast, FESS Sinu-Cleanse Hypertonic significantly reduced TEER 5 minutes after application of the solution followed by an increase in paracellular permeability of FITC-Dextrans (30 minutes) and increased LDH levels 6 hours after application of the solution. Our findings confirm that isotonic and hypertonic saline solutions do not compromise epithelial barrier function in vitro but underscore the importance of examining safety and efficacy of over-the-counter wash solutions.

  20. Efficacy of citric acid denture cleanser on the Candida albicans biofilm formed on poly(methyl methacrylate): effects on residual biofilm and recolonization process

    PubMed Central

    2014-01-01

    Background It is well known that the use of denture cleansers can reduce Candida albicans biofilm accumulation; however, the efficacy of citric acid denture cleansers is uncertain. In addition, the long-term efficacy of this denture cleanser is not well established, and their effect on residual biofilms is unknown. This in vitro study evaluated the efficacy of citric acid denture cleanser treatment on C. albicans biofilm recolonization on poly(methyl methacrylate) (PMMA) surface. Methods C. albicans biofilms were developed for 72 h on PMMA resin specimens (n = 168), which were randomly assigned to 1 of 3 cleansing treatments (CTs) overnight (8 h). CTs included purified water as a control (CTC) and two experimental groups that used either a 1:5 dilution of citric acid denture cleanser (CT5) or a 1:8 dilution of citric acid denture cleanser (CT8). Residual biofilms adhering to the specimens were collected and quantified at two time points: immediately after CTs (ICT) and after cleaning and residual biofilm recolonization (RT). Residual biofilms were analyzed by quantifying the viable cells (CFU/mL), and biofilm architecture was evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Denture cleanser treatments and evaluation periods were considered study factors. Data were analyzed using two-way ANOVA and Tukey’s Honestly Significant Difference (HSD) test (α = 0.05). Results Immediately after treatments, citric acid denture cleansing solutions (CT5 and CT8) reduced the number of viable cells as compared with the control (p < 0.01). However, after 48 h, both CT groups (CT5 and CT8) showed biofilm recolonization (p < 0.01). Residual biofilm recolonization was also detected by CLSM and SEM analysis, which revealed a higher biomass and average biofilm thickness for the CT8 group (p < 0.01). Conclusion Citric acid denture cleansers can reduce C. albicans biofilm accumulation and cell viability. However, this CT did not prevent biofilm recolonization. PMID:24957210

  1. Tomography experiment of an integrated circuit specimen using 3 MeV electrons in the transmission electron microscope.

    PubMed

    Zhang, Hai-Bo; Zhang, Xiang-Liang; Wang, Yong; Takaoka, Akio

    2007-01-01

    The possibility of utilizing high-energy electron tomography to characterize the micron-scale three dimensional (3D) structures of integrated circuits has been demonstrated experimentally. First, electron transmission through a tilted SiO(2) film was measured with an ultrahigh-voltage electron microscope (ultra-HVEM) and analyzed from the point of view of elastic scattering of electrons, showing that linear attenuation of the logarithmic electron transmission still holds valid for effective specimen thicknesses up to 5 microm under 2 MV accelerating voltages. Electron tomography of a micron-order thick integrated circuit specimen including the Cu/via interconnect was then tried with 3 MeV electrons in the ultra-HVEM. Serial projection images of the specimen tilted at different angles over the range of +/-90 degrees were acquired, and 3D reconstruction was performed with the images by means of the IMOD software package. Consequently, the 3D structures of the Cu lines, via and void, were revealed by cross sections and surface rendering.

  2. Cleansing orthodontic brackets with air-powder polishing: effects on frictional force and degree of debris.

    PubMed

    Leite, Brisa Dos Santos; Fagundes, Nathalia Carolina Fernandes; Aragón, Mônica Lídia Castro; Dias, Carmen Gilda Barroso Tavares; Normando, David

    2016-01-01

    Debris buildup on the bracket-wire interface can influence friction. Cleansing brackets with air-powder polishing can affect this process. The aim of this study was to evaluate the frictional force and amount of debris remaining on orthodontic brackets subjected to prophylaxis with air-powder polishing. Frictional force and debris buildup on the surface of 28 premolar brackets were evaluated after orthodontic treatment. In one hemiarch, each bracket was subjected to air-powder polishing (n = 14) for five seconds, while the contralateral hemiarch (n = 14) served as control. Mechanical friction tests were performed and images of the polished bracket surfaces and control surfaces were examined. Wilcoxon test was applied for comparative analysis between hemiarches at p < 0.05. Brackets that had been cleaned with air-powder polishing showed lower friction (median = 1.27 N) when compared to the control surfaces (median = 4.52 N) (p < 0.01). Image analysis showed that the control group exhibited greater debris buildup (median = 2.0) compared with the group that received prophylaxis with air-powder polishing (median = 0.5) (p < 0.05). Cleansing orthodontic brackets with air-powder polishing significantly reduces debris buildup on the bracket surface while decreasing friction levels observed during sliding mechanics.

  3. Overshooting of Clean Tropospheric Air in the Tropical Lower Stratosphere as Seen by the CALIPSO Lidar

    NASA Technical Reports Server (NTRS)

    Vernier, J. P.; Pommereau, J. P.; Thomason, L. W.; Pelon, J.; Garnier, A.; Deshler, T.; Jumelet, J.; Nielsen, J. K.

    2011-01-01

    The evolution of aerosols in the tropical upper troposphere/lower stratosphere between June 2006 and October 2009 is examined using the observations of the space borne CALIOP lidar aboard the CALIPSO satellite. Superimposed on several volcanic plumes and soot from an extreme biomass-burning event in 2009, the measurements reveal the existence of fast cleansing episodes of the lower stratosphere to altitudes as high as 20 km. The cleansing of the full 14-20km layer takes place within 1-4 months. Its coincidence with the maximum of convective activity in the southern tropics, suggests that the cleansing is the result of a large number of overshooting towers, injecting aerosol-poor tropospheric air into the lower stratosphere. The enhancements of aerosols at the tropopause level during the NH summer may be due to the same transport process but associated with intense sources of aerosols at the surface. Since, the tropospheric air flux derived from CALIOP observations during North Hemisphere winter is 5 20 times larger than the slow ascent by radiative heating usually assumed, the observations suggest that convective overshooting is a major contributor to troposphere-to-stratosphere transport with concommitant implications to the Tropical Tropopause Layer top height, chemistry and thermal structure.

  4. Colorectal cancer screening with virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Ge, Yaorong; Vining, David J.; Ahn, David K.; Stelts, David R.

    1999-05-01

    Early detection and removal of colorectal polyps have been proven to reduce mortality from colorectal carcinoma (CRC), the second leading cause of cancer deaths in the United States. Unfortunately, traditional techniques for CRC examination (i.e., barium enema, sigmoidoscopy, and colonoscopy) are unsuitable for mass screening because of either low accuracy or poor public acceptance, costs, and risks. Virtual colonoscopy (VC) is a minimally invasive alternative that is based on tomographic scanning of the colon. After a patient's bowel is optimally cleansed and distended with gas, a fast tomographic scan, typically helical computed tomography (CT), of the abdomen is performed during a single breath-hold acquisition. Two-dimensional (2D) slices and three-dimensional (3D) rendered views of the colon lumen generated from the tomographic data are then examined for colorectal polyps. Recent clinical studies conducted at several institutions including ours have shown great potential for this technology to be an effective CRC screening tool. In this paper, we describe new methods to improve bowel preparation, colon lumen visualization, colon segmentation, and polyp detection. Our initial results show that VC with the new bowel preparation and imaging protocol is capable of achieving accuracy comparable to conventional colonoscopy and our new algorithms for image analysis contribute to increased accuracy and efficiency in VC examinations.

  5. Transplantation of Cadaver Tissues and Organs. Part 15. Chapter 338

    DTIC Science & Technology

    1984-01-09

    different individuals should preferentially be nonviable and cleansed * •of cellular debris. * N moral and legal issues most often surround the...there is a minority who view such a position as immoral,that the individual expires only when all vegetative function ceases. 3 i Ii i ŕ " Donald J...Drug Adminstration in 1982 has ruled processed bone * as a "device", which qualifies under the Federal Food, Drug and Cosmetic Act, Medical Device

  6. Comparison of the Effectiveness of Four Different Types of Needles in Irrigating Endodontically Treated Teeth.

    DTIC Science & Technology

    1980-02-08

    3. Shih, M.; Marshall, F. J.; and Rosen, S. The bactericidal efficiency of sodium hypochlorite as an endodontic irrigant. Oral Surg 29(4): 613-619...and Rosen9 investi- gated the cleansing effect of sodium hypochlorite and normal saline on the apical one third using a standard irrigating method. They...found that sodium hypochlorite was no better than normal saline solutiun in irrigating this segment. Salzgeber and Brilliant10 investigated the

  7. 2 L PEG plus ascorbic acid versus 4 L PEG plus simethicon for colonoscopy preparation: a randomized single-blind clinical trial.

    PubMed

    Gentile, Maurizio; De Rosa, Michele; Cestaro, Giovanni; Forestieri, Pietro

    2013-06-01

    The 2 L polyethylene glycol (PEG) lavage solution has been proved to be similarly safe and effective as 4 L PEG formulations, in spite of the reduced volume. To compare low-volume PEG-based solution combined with ascorbic acid with high-volume PEG-based solution combined with simethicon in terms of efficacy and patient tolerability. This was a single-blind prospective randomized trial. Patients were randomized to receive either 2 L PEG plus ascorbic acid (PEG+Asc) or 4 L PEG plus simethicon (PEG+Sim). The primary endpoint was overall colon cleansing evaluation, assessed by blinded investigators using Aronchick score. Secondary end points included patient compliance and tolerability and adverse events. Sixty patients received PEG+Asc and 60 received PEG+Sim. Overall bowel cleansing score was considered adequate in 81.67% of the PEG+Asc and 80% of the PEG+Sim groups, respectively. Excellent and good ratings were recorded in 11.6% and 38.3% receiving PEG+Asc as compared with 26.6% and 23.3% of patients receiving PEG+Sim. Patient tolerability and safety were similar with both the preparations. According to our data, low-volume PEG+Asc has comparable efficacy, safety, and tolerability as high-volume PEG+Sim; therefore, it can be considered as a good alternative solution for bowel preparation. More improvements are necessary to achieve the target of a perfect preparation.

  8. Supercritical CO2 extract from strawberry seeds as a valuable component of mild cleansing compositions.

    PubMed

    Sikora, E; Michorczyk, P; Olszańska, M; Ogonowski, J

    2015-12-01

    The aim of this work was an elaboration of mild cleansing compositions, containing supercritical CO2 extract from strawberry seeds (SC-CO2 strawberry seed oil), as a moisturizing and skin-softening agent. The influence of concentration of the oil on user properties of shower/bath products was studied. A series of products (shower/bath cosmetics) composed mainly of mild surfactants (amphoacetates, sulfosuccinates, betaines) and containing different amounts of the oil (0.5 up to 5.0%) were prepared. For the stable products (formulations containing up to 2% of the oil), the influence of the SC-CO2 strawberry seed oil addition on the products' stability, foam ability, surface tension, pH and rheological properties was studied. Moreover, the skin compatibility and moisturizing efficiency of the cleansing products were recorded in a group of 15 volunteers (including 10 women and five men, aged 20-30 years), using skin diagnosis system AramoTS, Aram Huvis Co. Additionally, characterization of CO2 extract from strawberry seeds was performed. Measurements of the oil's analytical constants, that is acid value and saponification number, were conducted according to Polish Standard PN-EN ISO 660:2010 and PN-EN ISO 3657:2013, respectively. The oil concentration influences stability of the products. Only the formulations containing 0.5-2% of the extract have shown high stability. Moreover, used in the amount up to 2% the SC-CO2, strawberry seed oil does not affect significantly the cleansing and foaming properties of the products. The obtained shower/bath cosmetics showed good user properties and additionally good skin-moisturizing effect. The supercritical CO2 extract from strawberry seeds, rich source of unsaturated fatty acid, could be successfully used in the formulation of body washing compositions as a moisturizing and skin-softening agent. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  9. [Comparison of colon-cleansing methods in preparation for colonoscopy-comparative of solutions of mannitol and sodium picosulfate].

    PubMed

    de Moura, Diogo Turiani; Guedes, Hugo; Tortoretto, Verônica; Arataque, Tayrê Pádua; de Moura, Eduardo Guimarães; Román, Juan Pablo; Rodela, Gustavo Luis; Artifon, Everson L

    2016-01-01

    The purpose of the present study is to compare intestinal preparation with mannitol and sodium picosulphate, assessing patient's acceptance, side effects and cleaning capacity. This is a prospective, nom randomized, blind study, in which the evaluator had no information about the preparation applied. The sample obtained was divided into two groups according to the bowel preparation applied, with 153 patients prepared with 10% mannitol and 84 patients with sodium picosulfate. The evaluation of colon preparation was done using the Boston Scale (Boston Bowel Preparation Scale - BBP) through a three-point scoring system for each of the three regions of the colon: right, left and transverse colon. Of the 237 patients that were evaluated, 146 (61.60%) were female and 91 (38.4%) were male. Regarding the group that used mannitol, 98 were female (64.05%) and 55 were male (35.95%). Among the patients who used sodium picosulfate, 48 were female (57.14%) and 36 were male (42.86%), with no statistical differences between both groups (p> 0.32). Considering that an adequate preparation scores ≥ 6 in the Boston Scale, the bowel cleansing preparation was satisfactory in both groups. 93% of the patients who used mannitol and 81% of the patients who used sodium picosulfate had adequate preparation (score of ≥ 6). Moreover, we consider that the average score in the preparation with Mannitol was 9, while the sodium picosulfate score was 7. There were no significant differences between the two groups. There is consensus among authors who state that colonoscopy's safety and success are highly related to the cleansing outcome, regardless of the method used. The same can be observed in the present study, on which both preparations were proved safe and effective for bowel cleansing, according to the Boston scale, as well as accepted by patients and free of complications.

  10. MiraLAX is not as effective as GoLytely in bowel cleansing before screening colonoscopies.

    PubMed

    Hjelkrem, Michael; Stengel, Joel; Liu, Mark; Jones, David P; Harrison, Stephen A

    2011-04-01

    Successful colonoscopies require good bowel preparations-poor bowel preparations can increase medical costs, rates of missed lesions, and procedure duration. The combination of polyethylene glycol (PEG) 3350 without electrolytes (MiraLAX; Schering-Plough Healthcare Products, Inc, Kenilworth, NJ) and 64 oz of Gatorade (PepsiCo, Inc, Purchase, NY) has gained popularity as a bowel preparation regimen. However, the efficacy and tolerability of this approach has not been compared with standard bowel preparations in clinical trials. We compared split-dose (PEG) 3350 with electrolytes (GoLytely; Braintree Laboratories, Inc, Braintree, MA) with split-dose MiraLAX alone and in combination with pretreatment medications (bisacodyl or lubiprostone) to determine the efficacy and patient tolerability of MiraLAX as an agent for bowel preparation. We performed a prospective, randomized, blinded, controlled trial at a tertiary care center. Patients (n=403) were randomly assigned to groups given GoLytely, MiraLAX, MiraLAX with bisacodyl (10 mg), or MiraLAX with lubiprostone (24 μg). MiraLAX was combined with 64 oz of Gatorade. All patients were surveyed regarding preparation satisfaction and tolerability. The Ottawa bowel preparation scale was used to grade colon cleanliness. GoLytely was more effective at bowel cleansing (average Ottawa score, 5.1) than MiraLAX alone (average Ottawa score, 6.9) or in combination with lubiprostone (average Ottawa score, 6.8), or bisacodyl (average Ottawa score, 6.3) (P<.001). MiraLAX was associated with a trend toward longer procedure duration (P=.096). Groups given MiraLAX rated the overall experience as more satisfactory than those given GoLytely (P<.001). There were no differences between polyp detection rates (P=.346) or adverse events (P=.823). Split-dose MiraLAX in 64 oz of Gatorade is not as effective as 4 L split-dose GoLytely in bowel cleansing for screening colonoscopies. Copyright © 2011 AGA Institute. Published by Elsevier Inc. All rights reserved.

  11. Orange juice intake reduces patient discomfort and is effective for bowel cleansing with polyethylene glycol during bowel preparation.

    PubMed

    Choi, Hong Seok; Shim, Chan Sup; Kim, Gyu Won; Kim, Jung Seok; Lee, Sun-Young; Sung, In-Kyung; Park, Hyung Seok; Kim, Jeong Hwan

    2014-10-01

    Many patients report discomfort because of the unpleasant taste of bowel preparation solutions. This study aimed to determine whether adding orange juice to 2 L of polyethylene glycol plus ascorbic acid is effective for reducing patient discomfort and improving palatability during bowel preparation. This was a single-blinded, randomized controlled trial. The study was conducted at a tertiary referral hospital and a generalized hospital. Consecutive outpatients and inpatients were randomly allocated to drink 2 L of polyethylene glycol-ascorbic acid or 2 L of polyethylene glycol-ascorbic acid with orange juice in a single dose or a split dose. Tolerability, palatability score, willingness, and related adverse events were investigated by questionnaires. Bowel cleansing was rated using the Aronchick scale. Each score was graded on a 5-point scale. A total of 107 patients, 53 in the orange juice group and 54 in the polyethylene glycol-ascorbic acid group who underwent elective colonoscopy were enrolled. The palatability score (mean ± SD) was higher in the orange juice group than in the control group (2.36 ± 0.76 vs 1.78 ± 0.88; p = 0.005). Nausea was less frequent in the orange juice group (26.4% vs 59.3%; p = 0.001). Total amount of bowel preparation ingested was not significantly different between the groups (p = 0.44). The bowel preparation score (mean ± SD) was not significantly different (1.49 ± 0.80 vs 1.43 ± 0.77; p = 0.94). Willingness to repeat the same process was higher in the orange juice group (90.4% vs 66.7%; p = 0.003). This study is limited because only ambulatory patients were enrolled. Orange juice intake before drinking 2 L of polyethylene glycol-ascorbic acid for colonoscopy can reduce patient discomfort, resulting in improved acceptability and patient compliance. This method is as effective for bowel cleansing as polyethylene glycol.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong, J.Y.; Zhao, G.; Zhang, J.

    energy levels, spontaneous radiative decay rates, and electron impact collision strengths are calculated for La XXX. The data refer to 107 fine-structure levels belonging to the configurations (1s{sup 2}2s{sup 2}2p{sup 6})3s{sup 2}3p{sup 6}3d{sup 10}, 3s{sup 2}3p{sup 6}3d{sup 9}4l, 3s{sup 2}3p{sup 5}3d{sup 10}4l, and 3s3p{sup 6}3d{sup 10}4l (l = s, p, d, f). The collision strengths are calculated with a 20-collision-energy grid in terms of the energy of the scattered electron between 10 and 10,000 eV by using the distorted-wave approximation. Effective collision strengths are obtained at seven electron temperatures: T {sub e} (eV) = 10, 100, 300, 500, 800, 1000,more » and 1500 by integrating the collision strengths over a Maxwellian electron distribution. Coupled with these atomic data, a hydrodynamic code MED103 can be used to simulate the Ni-like La X-ray laser at 8.8 nm.« less

  13. Note: An improved 3D imaging system for electron-electron coincidence measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Yun Fei; Lee, Suk Kyoung; Adhikari, Pradip

    We demonstrate an improved imaging system that can achieve highly efficient 3D detection of two electrons in coincidence. The imaging system is based on a fast frame complementary metal-oxide semiconductor camera and a high-speed waveform digitizer. We have shown previously that this detection system is capable of 3D detection of ions and electrons with good temporal and spatial resolution. Here, we show that with a new timing analysis algorithm, this system can achieve an unprecedented dead-time (<0.7 ns) and dead-space (<1 mm) when detecting two electrons. A true zero dead-time detection is also demonstrated.

  14. Note: An improved 3D imaging system for electron-electron coincidence measurements

    NASA Astrophysics Data System (ADS)

    Lin, Yun Fei; Lee, Suk Kyoung; Adhikari, Pradip; Herath, Thushani; Lingenfelter, Steven; Winney, Alexander H.; Li, Wen

    2015-09-01

    We demonstrate an improved imaging system that can achieve highly efficient 3D detection of two electrons in coincidence. The imaging system is based on a fast frame complementary metal-oxide semiconductor camera and a high-speed waveform digitizer. We have shown previously that this detection system is capable of 3D detection of ions and electrons with good temporal and spatial resolution. Here, we show that with a new timing analysis algorithm, this system can achieve an unprecedented dead-time (<0.7 ns) and dead-space (<1 mm) when detecting two electrons. A true zero dead-time detection is also demonstrated.

  15. Enhanced electron mixing and heating in 3-D asymmetric reconnection at the Earth's magnetopause

    DOE PAGES

    Le, Ari Yitzchak; Daughton, William Scott; Chen, Li -Jen; ...

    2017-03-01

    Here, electron heating and mixing during asymmetric reconnection are studied with a 3-D kinetic simulation that matches plasma parameters from Magnetospheric Multiscale (MMS) spacecraft observations of a magnetopause diffusion region. The mixing and heating are strongly enhanced across the magnetospheric separatrix compared to a 2-D simulation. The transport of particles across the separatrix in 3-D is attributed to lower hybrid drift turbulence excited at the steep density gradient near the magnetopause. In the 3-D simulation (and not the 2-D simulation), the electron temperature parallel to the magnetic field within the mixing layer is significantly higher than its upstream value inmore » agreement with the MMS observations.« less

  16. Reactions of solvated electrons initiated by sodium atom ionization at the vacuum-liquid interface.

    PubMed

    Alexander, William A; Wiens, Justin P; Minton, Timothy K; Nathanson, Gilbert M

    2012-03-02

    Solvated electrons are powerful reagents in the liquid phase that break chemical bonds and thereby create additional reactive species, including hydrogen atoms. We explored the distinct chemistry that ensues when electrons are liberated near the liquid surface rather than within the bulk. Specifically, we detected the products resulting from exposure of liquid glycerol to a beam of sodium atoms. The Na atoms ionized in the surface region, generating electrons that reacted with deuterated glycerol, C(3)D(5)(OD)(3), to produce D atoms, D(2), D(2)O, and glycerol fragments. Surprisingly, 43 ± 4% of the D atoms traversed the interfacial region and desorbed into vacuum before attacking C-D bonds to produce D(2).

  17. Electron attachment to DNA single strands: gas phase and aqueous solution

    PubMed Central

    Gu, Jiande; Xie, Yaoming; Schaefer, Henry F.

    2007-01-01

    The 2′-deoxyguanosine-3′,5′-diphosphate, 2′-deoxyadenosine-3′,5′-diphosphate, 2′-deoxycytidine-3′,5′-diphosphate and 2′-deoxythymidine-3′,5′-diphosphate systems are the smallest units of a DNA single strand. Exploring these comprehensive subunits with reliable density functional methods enables one to approach reasonable predictions of the properties of DNA single strands. With these models, DNA single strands are found to have a strong tendency to capture low-energy electrons. The vertical attachment energies (VEAs) predicted for 3′,5′-dTDP (0.17 eV) and 3′,5′-dGDP (0.14 eV) indicate that both the thymine-rich and the guanine-rich DNA single strands have the ability to capture electrons. The adiabatic electron affinities (AEAs) of the nucleotides considered here range from 0.22 to 0.52 eV and follow the order 3′,5′-dTDP > 3′,5′-dCDP > 3′,5′-dGDP > 3′,5′-dADP. A substantial increase in the AEA is observed compared to that of the corresponding nucleic acid bases and the corresponding nucleosides. Furthermore, aqueous solution simulations dramatically increase the electron attracting properties of the DNA single strands. The present investigation illustrates that in the gas phase, the excess electron is situated both on the nucleobase and on the phosphate moiety for DNA single strands. However, the distribution of the extra negative charge is uneven. The attached electron favors the base moiety for the pyrimidine, while it prefers the 3′-phosphate subunit for the purine DNA single strands. In contrast, the attached electron is tightly bound to the base fragment for the cytidine, thymidine and adenosine nucleotides, while it almost exclusively resides in the vicinity of the 3′-phosphate group for the guanosine nucleotides due to the solvent effects. The comparatively low vertical detachment energies (VDEs) predicted for 3′,5′-dADP− (0.26 eV) and 3′,5′-dGDP− (0.32 eV) indicate that electron detachment might compete with reactions having high activation barriers such as glycosidic bond breakage. However, the radical anions of the pyrimidine nucleotides with high VDE are expected to be electronically stable. Thus the base-centered radical anions of the pyrimidine nucleotides might be the possible intermediates for DNA single-strand breakage. PMID:17660189

  18. Growth and nanomechanical characterization of nanoscale 3D architectures grown via focused electron beam induced deposition

    DOE PAGES

    Lewis, Brett B.; Mound, Brittnee A.; Srijanto, Bernadeta; ...

    2017-10-12

    Here, nanomechanical measurements of platinum–carbon 3D nanoscale architectures grown via focused electron beam induced deposition (FEBID) were performed using a nanoindentation system in a scanning electron microscope (SEM) for simultaneous in situ imaging.

  19. Electron heating at interplanetary shocks

    NASA Technical Reports Server (NTRS)

    Feldman, W. C.; Asbridge, J. R.; Bame, S. J.; Gosling, J. T.; Zwickl, R. D.

    1982-01-01

    Data for 41 forward interplanetary shocks show that the ratio of downstream to upstream electron temperatures, T/sub e/(d/u) is variable in the range between 1.0 (isothermal) and 3.0. On average, (T/sub e/(d/u) = 1.5 with a standard deviation, sigma e = 0.5. This ratio is less than the average ratio of proton temperatures across the same shocks, (T/sub p/(d/u)) = 3.3 with sigma p = 2.5 as well as the average ratio of electron temperatures across the Earth's bow shock. Individual samples of T/sub e/(d/u) and T/sub p/(d/u) appear to be weakly correlated with the number density ratio. However the amounts of electron and proton heating are well correlated with each other as well as with the bulk velocity difference across each shock. The stronger shocks appear to heat the protons relatively more efficiently than they heat the electrons.

  20. Significant enhancement of power conversion efficiency for dye sensitized solar cell using 1D/3D network nanostructures as photoanodes

    PubMed Central

    Wang, Hao; Wang, Baoyuan; Yu, Jichao; Hu, Yunxia; Xia, Chen; Zhang, Jun; Liu, Rong

    2015-01-01

    The single–crystalline TiO2 nanorod arrays with rutile phase have attracted much attention in the dye sensitized solar cells (DSSCs) applications because of their superior chemical stability, better electron transport properties, higher refractive index and low production cost. However, it suffers from a low surface area as compared with TiO2 nanoparticle films. In order to enlarge the surface area of TiO2 nanorod arrays, the 1D nanorods/3D nanotubes sample was synthesized using a facile two-step hydrothermal process involving hydrothermal growth 1D/3D nanorods and followed by post-etching treatment. In such bi-layer structure, the oriented TiO2 nanorods layer could provide direct pathway for fast electron transportation, and the 3D nanotubes layer offers a higher surface area for dye loading, therefore, the 1D nanorods/3D nanotubes photoanode exhibited faster electron transport and higher surface area than either 1D or 3D nanostructures alone, and an highest efficiency of 7.68% was achieved for the DSSCs based on 1D nanorods/3D nanotubes photoanode with further TiCl4 treatment. PMID:25800933

  1. Gd3+ spin-lattice relaxation via multi-band conduction electrons in Y(1-x)Gd(x)In3: an electron spin resonance study.

    PubMed

    Cabrera-Baez, M; Iwamoto, W; Magnavita, E T; Osorio-Guillén, J M; Ribeiro, R A; Avila, M A; Rettori, C

    2014-04-30

    Interest in the electronic structure of the intermetallic compound YIn3 has been renewed with the recent discovery of superconductivity at T ∼ 1 K, which may be filamentary in nature. In this work we perform electron spin resonance (ESR) experiments on Gd(3+) doped YIn3 (Y1-xGdxIn3; 0.001 ⪅ x ⩽̸ 0.08), showing that the spin-lattice relaxation of the Gd(3+) ions, due to the exchange interaction between the Gd(3+) localized magnetic moment and the conduction electrons (ce), is processed via the presence of s-, p- and d-type ce at the YIn3 Fermi level. These findings are revealed by the Gd(3+) concentration dependence of the Korringa-like relaxation rate d(ΔH)/dT and g-shift (Δg = g - 1.993), that display bottleneck relaxation behavior for the s-electrons and unbottleneck behavior for the p- and d-electrons. The Korringa-like relaxation rates vary from 22(2) Oe/K for x ⪅ 0.001 to 8(2) Oe/K for x = 0.08 and the g-shift values change, respectively, from a positive Δg = +0.047(10) to a negative Δg = -0.008(4). Analysis in terms of a three-band ce model allows the extraction of the corresponding exchange interaction parameters Jfs, Jfp and Jfd.

  2. Instability in the Post-Cold War World: A Model for Evaluation and Decision Making

    DTIC Science & Technology

    1993-04-15

    countries. 1 3 In Bosnia-Herzegovina the Serbs, a mainly Christian culture, use their religion as a partial justification for their "ethnic cleansing" of the...Bosnians, a predominately Moslem culture. The clash of religions is also central to the battles between the Moslem Azeris and the Christian Armenians...Russians of the trans-Dnester region. 14 Even Buddhism, renowned as a religion of peace, figures in conflicts. The low level civil unrest in Tibet is

  3. High efficiency and non-Richardson thermionics in three dimensional Dirac materials

    NASA Astrophysics Data System (ADS)

    Huang, Sunchao; Sanderson, Matthew; Zhang, Yan; Zhang, Chao

    2017-10-01

    Three dimensional (3D) topological materials have a linear energy dispersion and exhibit many electronic properties superior to conventional materials such as fast response times, high mobility, and chiral transport. In this work, we demonstrate that 3D Dirac materials also have advantages over conventional semiconductors and graphene in thermionic applications. The low emission current suffered in graphene due to the vanishing density of states is enhanced by an increased group velocity in 3D Dirac materials. Furthermore, the thermal energy carried by electrons in 3D Dirac materials is twice of that in conventional materials with a parabolic electron energy dispersion. As a result, 3D Dirac materials have the best thermal efficiency or coefficient of performance when compared to conventional semiconductors and graphene. The generalized Richardson-Dushman law in 3D Dirac materials is derived. The law exhibits the interplay of the reduced density of states and enhanced emission velocity.

  4. Department of Defense CHAMPUS Ambulatory Professional Services Summary Analysis, Fiscal Year 1991

    DTIC Science & Technology

    1991-11-21

    CONTINUED) CPT4 TOTAL AD RET/ RET/DEC CODE CPT4 NAME (SHORT) PROC DEP PCT DEC PCT DEP PCT 97520 PROSTHETIC TRAINING 40 11 27.5% 8 20.0% 21 52.5% 93510...219 27.8% 491 62.2% 51726 COMPLEX CYSTOMETROGRAM 782 207 26.5% 146 18.7% 429 54.9% 25600 TREAT FRACTURE RADIUS/ULN 754 509 67.5% 25 3.3% 220 29.2...11701 SURGICAL CLEANSING OF NAI 483 19 3.9. 146 30.2% 318 65.8% 25605 TREAT FRACTURE RADIUS/ULN 482 254 52.7% 26 5.4% 202 41.9% 51720 TREATMENT OF

  5. Electronic and structural reconstruction in titanate heterostructures from first principles

    NASA Astrophysics Data System (ADS)

    Mulder, Andrew T.; Fennie, Craig J.

    2014-03-01

    Recent advances in transition metal oxide heterostructures have opened new routes to create materials with novel functionalities and properties. One direction has been to combine a Mott insulating perovskite with an electronic d1 configuration, such as LaTiO3, with a band insulating d0 perovskite, such as SrTiO3. An exciting recent development is the demonstration of interfacial conductivity in GdTiO3/SrTiO3 heterostructures that display a complex structural motif of octahedral rotations and ferromagnetic properties similar to bulk GdTiO3. In this talk we present our first principles investigation of the interplay of structural, electronic, magnetic, and orbital degrees of freedom for a wide range of d1/d0 titanate heterostructures. We find evidence for both rotation driven ferroelectricity and a symmetry breaking electronic reconstruction with a concomitant structural distortion at the interface. We argue that these materials represent an ideal platform to realize novel functionalities such as the electric field control of electronic and magnetic properties.

  6. The optical design of 3D ICs for smartphone and optro-electronics sensing module

    NASA Astrophysics Data System (ADS)

    Huang, Jiun-Woei

    2018-03-01

    Smartphone require limit space for image system, current lens, used in smartphones are refractive type, the effective focal length is limited the thickness of phone physical size. Other, such as optro-electronics sensing chips, proximity optical sensors, and UV indexer chips are integrated into smart phone with limit space. Due to the requirement of multiple lens in smartphone, proximity optical sensors, UV indexer and other optro-electronics sensing chips in a limited space of CPU board in future smart phone, optro-electronics 3D IC's integrated with optical lens or components may be a key technology for 3 C products. A design for reflective lens is fitted to CMOS, proximity optical sensors, UV indexer and other optro-electronics sensing chips based on 3-D IC. The reflective lens can be threes times of effective focal lens, and be able to resolve small object. The system will be assembled and integrated in one 3-D IC more easily.

  7. The Energy Spectrum of Jovian Electrons in Interplanetary Space

    NASA Technical Reports Server (NTRS)

    Christon, S. P.; Cummings, A. C.; Stone, E. C.; Webber, W. R.

    1985-01-01

    The energy spectrum of electrons with energies approx 10 to approx 180 MeV measured with the electron telescope on the Voyager 1 and 2 spacecraft in interplanetary space from 1978 to 1983 is studied. The kinetic energy of electrons is determined by double dE/dx measurements from the first two detectors (D sub 1, D sub 2) of a stack of eight solid state detectors and by the range of particle penetration into the remaining six detectors (D sub 3 to D sub 8) which are interleaved with tungsten absorbers. From 1978 to 1983 (radial range approximately 2 to a pproximately 12 AU) electrons of Jovian origin were clearly observable for electrons stopping in D(sub 3(E approximately greater than 4 MeV)) and in D(sub 4 (E approximately greater than 8 MeV)). For electrons stopping in D(sub 5(E approximately greather than 12 MeV)), the jovian flux dominated the galactic electron flux for a period of approximately one year near the encounter with Jupiter. Jovian electrons were also observed in D(sub 6(E approximately greater than 21 MeV)) but not in D(sub 7(E approximately greater than 28 MeV)). A detailed interpretation of the electron variations in all energy channels depends on an accurate subtraction of background induced by energetic protons of a few 100 MeV. This substraction is facilitated by laboratory calibration results at several energies. Further results on the differential energy spectrum of Jovian electrons and limits on the maximum detected energies will be reported.

  8. The formation of DNA sugar radicals from photoexcitation of guanine cation radicals.

    PubMed

    Shukla, Lata I; Pazdro, Robert; Huang, James; DeVreugd, Christopher; Becker, David; Sevilla, Michael D

    2004-05-01

    In this investigation of radical formation and reaction in gamma- irradiated DNA and model compounds, we report the conversion of the guanine cation radical (one-electron oxidized guanine, G(.+)) to the C1' sugar radical and another sugar radical at the C3' or C4' position (designated C3'(.)/C4'(.)) by visible and UV photolysis. Electron spin resonance (ESR) spectroscopic investigations were performed on salmon testes DNA as well as 5'-dGMP, 3'-dGMP, 2'-deoxyguanosine and other nucleosides/nucleotides as model systems. DNA samples (25- 150 mg/ml D(2)O) were prepared with Tl(3+) or Fe(CN)(3-)(6) as electron scavengers. Upon gamma irradiation of such samples at 77 K, the electron-gain path in the DNA is strongly suppressed and predominantly G(.+) is found; after UV or visible photolysis, the fraction of the C1' sugar radical increases with a concomitant reduction in the fraction of G(.+). In model systems, 3'- dGMP(+.) and 5'-dGMP(+.) were produced by attack of Cl(.-)(2) on the parent nucleotide in 7 M LiCl glass. Subsequent visible photolysis of the 3'-dGMP(+.) (77 K) results predominantly in formation of C1'(.) whereas photolysis of 5'-dGMP(+.) results predominantly in formation of C3'(.)/C4'(.). We propose that sugar radical formation is a result of delocalization of the hole in the electronically excited base cation radical into the sugar ring, followed by deprotonation at specific sites on the sugar.

  9. 3D structure of individual nanocrystals in solution by electron microscopy

    NASA Astrophysics Data System (ADS)

    Park, Jungwon; Elmlund, Hans; Ercius, Peter; Yuk, Jong Min; Limmer, David T.; Chen, Qian; Kim, Kwanpyo; Han, Sang Hoon; Weitz, David A.; Zettl, A.; Alivisatos, A. Paul

    2015-07-01

    Knowledge about the synthesis, growth mechanisms, and physical properties of colloidal nanoparticles has been limited by technical impediments. We introduce a method for determining three-dimensional (3D) structures of individual nanoparticles in solution. We combine a graphene liquid cell, high-resolution transmission electron microscopy, a direct electron detector, and an algorithm for single-particle 3D reconstruction originally developed for analysis of biological molecules. This method yielded two 3D structures of individual platinum nanocrystals at near-atomic resolution. Because our method derives the 3D structure from images of individual nanoparticles rotating freely in solution, it enables the analysis of heterogeneous populations of potentially unordered nanoparticles that are synthesized in solution, thereby providing a means to understand the structure and stability of defects at the nanoscale.

  10. Electronic structure of charge- and spin-controlled Sr(1-(x+y))La(x+y)Ti(1-x)Cr(x)O3.

    PubMed

    Iwasawa, H; Yamakawa, K; Saitoh, T; Inaba, J; Katsufuji, T; Higashiguchi, M; Shimada, K; Namatame, H; Taniguchi, M

    2006-02-17

    We present the electronic structure of Sr(1-(x+y))La(x+y)Ti(1-x)Cr(x)O3 investigated by high-resolution photoemission spectroscopy. In the vicinity of the Fermi level, it was found that the electronic structure was composed of a Cr 3d local state with the t(2g)3 configuration and a Ti 3d itinerant state. The energy levels of these Cr and Ti 3d states are well interpreted by the difference of the charge-transfer energy of both ions. The spectral weight of the Cr 3d state is completely proportional to the spin concentration x irrespective of the carrier concentration y, indicating that the spin density can be controlled by x as desired. In contrast, the spectral weight of the Ti 3d state is not proportional to y, depending on the amount of Cr doping.

  11. A Method for 3D-Reconstruction of a Muscle Thick Filament Using the Tilt Series Images of a Single Filament Electron Tomogram

    PubMed Central

    Márquez, G.; Pinto, A.; Alamo, L.; Baumann, B.; Ye, F.; Winkler, H.; Taylor, K.; Padrón, R.

    2014-01-01

    Summary Myosin interacting-heads (MIH) motifs are visualized in 3D-reconstructions of thick filaments from striated muscle. These reconstructions are calculated by averaging methods using images from electron micrographs of grids prepared using numerous filament preparations. Here we propose an alternative method to calculate the 3D-reconstruction of a single thick filament using only a tilt series images recorded by electron tomography. Relaxed thick filaments, prepared from tarantula leg muscle homogenates, were negatively stained. Single-axis tilt series of single isolated thick filaments were obtained with the electron microscope at a low electron dose, and recorded on a CCD camera by electron tomography. An IHRSR 3D-recontruction was calculated from the tilt series images of a single thick filament. The reconstruction was enhanced by including in the search stage dual tilt image segments while only single tilt along the filament axis is usually used, as well as applying a band pass filter just before the back projection. The reconstruction from a single filament has a 40 Å resolution and clearly shows the presence of MIH motifs. In contrast, the electron tomogram 3D-reconstruction of the same thick filament –calculated without any image averaging and/or imposition of helical symmetry- only reveals MIH motifs infrequently. This is –to our knowledge- the first application of the IHRSR method to calculate a 3D reconstruction from tilt series images. This single filament IHRSR reconstruction method (SF-IHRSR) should provide a new tool to assess structural differences between well-ordered thick (or thin) filaments in a grid by recording separately their electron tomograms. PMID:24727133

  12. A method for 3D-reconstruction of a muscle thick filament using the tilt series images of a single filament electron tomogram.

    PubMed

    Márquez, G; Pinto, A; Alamo, L; Baumann, B; Ye, F; Winkler, H; Taylor, K; Padrón, R

    2014-05-01

    Myosin interacting-heads (MIH) motifs are visualized in 3D-reconstructions of thick filaments from striated muscle. These reconstructions are calculated by averaging methods using images from electron micrographs of grids prepared using numerous filament preparations. Here we propose an alternative method to calculate the 3D-reconstruction of a single thick filament using only a tilt series images recorded by electron tomography. Relaxed thick filaments, prepared from tarantula leg muscle homogenates, were negatively stained. Single-axis tilt series of single isolated thick filaments were obtained with the electron microscope at a low electron dose, and recorded on a CCD camera by electron tomography. An IHRSR 3D-recontruction was calculated from the tilt series images of a single thick filament. The reconstruction was enhanced by including in the search stage dual tilt image segments while only single tilt along the filament axis is usually used, as well as applying a band pass filter just before the back projection. The reconstruction from a single filament has a 40 Å resolution and clearly shows the presence of MIH motifs. In contrast, the electron tomogram 3D-reconstruction of the same thick filament - calculated without any image averaging and/or imposition of helical symmetry - only reveals MIH motifs infrequently. This is - to our knowledge - the first application of the IHRSR method to calculate a 3D reconstruction from tilt series images. This single filament IHRSR reconstruction method (SF-IHRSR) should provide a new tool to assess structural differences between well-ordered thick (or thin) filaments in a grid by recording separately their electron tomograms. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. 3D Printed Stretchable Tactile Sensors.

    PubMed

    Guo, Shuang-Zhuang; Qiu, Kaiyan; Meng, Fanben; Park, Sung Hyun; McAlpine, Michael C

    2017-07-01

    The development of methods for the 3D printing of multifunctional devices could impact areas ranging from wearable electronics and energy harvesting devices to smart prosthetics and human-machine interfaces. Recently, the development of stretchable electronic devices has accelerated, concomitant with advances in functional materials and fabrication processes. In particular, novel strategies have been developed to enable the intimate biointegration of wearable electronic devices with human skin in ways that bypass the mechanical and thermal restrictions of traditional microfabrication technologies. Here, a multimaterial, multiscale, and multifunctional 3D printing approach is employed to fabricate 3D tactile sensors under ambient conditions conformally onto freeform surfaces. The customized sensor is demonstrated with the capabilities of detecting and differentiating human movements, including pulse monitoring and finger motions. The custom 3D printing of functional materials and devices opens new routes for the biointegration of various sensors in wearable electronics systems, and toward advanced bionic skin applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Reduced electronic correlation effects in half substituted Ba(Fe1-xCox)2As2

    NASA Astrophysics Data System (ADS)

    Liu, Z.-H.; Yaresko, A. N.; Li, Y.; Evtushinsky, D. V.; Dai, P.-C.; Borisenko, S. V.

    2018-06-01

    We report a comprehensive study of the tridimensional nature and orbital character of the low-energy electronic structure in 50% Cobalt doped Ba(Fe1-xCox)2As2 (d6.5), by using polarization- and photon energy-dependent angle-resolved photoemission spectroscopy. An extra electron-like Fermi surface is observed around the Brillouin zone boundary compared with isoelectronic KyFe2-xSe2 (d6.5). The bands near the Fermi level (EF) are mainly derived from Fe/Co 3d t2g orbitals, revealing visible dispersions along the kz direction. In combination with the local density approximation and the dynamical mean-field theory calculations, we find that the As 4p bands are non-renormalized and the whole 3d band needs to be renormalized by a "single" factor of ˜1.6, indicating moderate electronic correlation effects. The "single" factor description of the correlation strength among the different 3d orbitals is also in sharp contrast to orbital-dependent correlation effects in BaFe2As2. Our findings indicate a remarkable reduction of correlation effects with little difference among 3d orbitals in BaFeCoAs2, due to the increased filling of the electronic 3d shell in the presence of significant Hund's coupling. The results support that the electronic correlation effects and multiple orbital physics play an important role in the superconductivity of the 122 system and in other ferropnictides.

  15. Change of Auger-electron emission from Ni-Pd alloys under magnetic phase transition

    NASA Astrophysics Data System (ADS)

    Elovikov, S. S.; Zykova, E. Y.; Gvozdover, R. S.; Colligon, J. S.; Yurasova, V. E.

    2006-04-01

    The change of Auger-electron emission from polycrystals of disordered ferromagnetic NiPd 3 and Ni 3 Pd alloys, under ferro- to paramagnetic transition, has been studied experimentally. It has been shown that the intensity of the Auger-lines, which are formed because of transition of valent zone 3d 3/2 and 3d 5/2 electrons, has local maxima near the Curie point T C for the alloys. Thus, the sensitivity of Auger-electron emission to a magnetic state of the alloy has been established.

  16. Influence of the Terminal Electron Donor in D-D-π-A Organic Dye-Sensitized Solar Cells: Dithieno[3,2-b:2',3'-d]pyrrole versus Bis(amine).

    PubMed

    Dai, Panpan; Yang, Lin; Liang, Mao; Dong, Huanhuan; Wang, Peng; Zhang, Chunyao; Sun, Zhe; Xue, Song

    2015-10-14

    With respect to the electron-withdrawing acceptors of D-A-π-A organic dyes, reports on the second electron-donating donors for D-D-π-A organic dyes are very limited. Both of the dyes have attracted significant attention in the field of dye-sensitized solar cells (DSCs). In this work, four new D-D-π-A organic dyes with dithieno[3,2-b:2',3'-d]pyrrole (DTP) or bis(amine) donor have been designed and synthesized for a investigation of the influence of the terminal electron donor in D-D-π-A organic dye-sensitized solar cells. It is found that DTP is a promising building block as the terminal electron donor when introduced in the dithiophenepyrrole direction, but not just a good bridge, which exhibits several characteristics: (i) efficiently increasing the maximum molar absorption coefficient and extending the absorption bands; (ii) showing stronger charge transfer interaction as compared with the pyrrole direction; (iii) beneficial to photocurrent generation of DSCs employing cobalt electrolytes. DSCs based on M45 with the Co-phen electrolyte exhibit good light-to-electric energy conversion efficiencies as high as 9.02%, with a short circuit current density (JSC) of 15.3 mA cm(-2), open circuit voltage (VOC) of 867 mV and fill factor (FF) of 0.68 under AM 1.5 illumination (100 mW cm(-2)). The results demonstrate that N,S-heterocycles such as DTP unit could be promising candidates for application in highly efficient DSCs employing cobalt electrolyte.

  17. Relativistic Laser Absorption and Magnetic Field Channel Formation in 3D PIC Simulation

    NASA Astrophysics Data System (ADS)

    Sentoku, Yasuhiko; Mima, Kunioki; Sheng, Zheng-Ming; Kaw, Predhiman; Nishihara, Katsunobu; Nishikawa, Kyoji

    2000-10-01

    We carried out 3D PIC simulations on overdense plasmas. On the surface of the plasmas, relativistic electrons are generated and transported into overdense plasmas. In the transport, it is found that energy is transferred to dense plasmas by convective cells. Namely, hot electron and cold electron return flows form convective cells through the magnetic instabilities (e.g. Weibel Instability). The heat flux associating with the convective cells and the anomalous stoppings in 3D simulations are compared with these in 2D simulations by Meyer-ter-Vehn etal. and Taguchi etal. [1] M. Honda, J. Meyer-ter-Vehn, and A. Pukhov, Phys. Plasmas 7, 1302, (2000). [2] ``Relativistic Electron Transport Simulation by 2D hybrid Simulation with Darwin Approximation." by T. Taguchi etal. (to be present in the poster of this conference)

  18. Electronic structure of dense Pb overlayers on Si(111) investigated using angle-resolved photoemission

    NASA Astrophysics Data System (ADS)

    Choi, W. H.; Koh, H.; Rotenberg, E.; Yeom, H. W.

    2007-02-01

    Dense Pb overlayers on Si(111) are important as the wetting layer for anomalous Pb island growth as well as for their own complex “devil’s-staircase” phases. The electronic structures of dense Pb overlayers on Si(111) were investigated in detail by angle-resolved photoemission. Among the series of ordered phases found recently above one monolayer, the low-coverage 7×3 and the high-coverage 14×3 phases are studied; they are well ordered and form reproducibly in large areas. The band dispersions and Fermi surfaces of the two-dimensional (2D) electronic states of these overlayers are mapped out. A number of metallic surface-state bands are identified for both phases with complex Fermi contours. The basic features of the observed Fermi contours can be explained by overlapping 2D free-electron-like Fermi circles. This analysis reveals that the 2D electrons near the Fermi level of the 7×3 and 14×3 phases are mainly governed by strong 1×1 and 3×3 potentials, respectively. The origins of the 2D electronic states and their apparent Fermi surface shapes are discussed based on recent structure models.

  19. Tunable Electron-Electron Interactions in LaAlO 3 / SrTiO 3 Nanostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Guanglei; Tomczyk, Michelle; Tacla, Alexandre B.

    The interface between the two complex oxides LaAlO 3 and SrTiO 3 has remarkable properties that can be locally reconfigured between conducting and insulating states using a conductive atomic force microscope. Prior investigations of “sketched” quantum dot devices revealed a phase in which electrons form pairs, implying a strongly attractive electron-electron interaction. Here, we show that these devices with strong electron-electron interactions can exhibit a gate-tunable transition from a pair-tunneling regime to a single-electron (Andreev bound state) tunneling regime where the interactions become repulsive. The electron-electron interaction sign change is associated with a Lifshitz transition where the d xz andmore » d yz bands start to become occupied. This electronically tunable electron-electron interaction, combined with the nanoscale reconfigurability of this system, provides an interesting starting point towards solid-state quantum simulation.« less

  20. Tunable Electron-Electron Interactions in LaAlO 3 / SrTiO 3 Nanostructures

    DOE PAGES

    Cheng, Guanglei; Tomczyk, Michelle; Tacla, Alexandre B.; ...

    2016-12-01

    The interface between the two complex oxides LaAlO 3 and SrTiO 3 has remarkable properties that can be locally reconfigured between conducting and insulating states using a conductive atomic force microscope. Prior investigations of “sketched” quantum dot devices revealed a phase in which electrons form pairs, implying a strongly attractive electron-electron interaction. Here, we show that these devices with strong electron-electron interactions can exhibit a gate-tunable transition from a pair-tunneling regime to a single-electron (Andreev bound state) tunneling regime where the interactions become repulsive. The electron-electron interaction sign change is associated with a Lifshitz transition where the d xz andmore » d yz bands start to become occupied. This electronically tunable electron-electron interaction, combined with the nanoscale reconfigurability of this system, provides an interesting starting point towards solid-state quantum simulation.« less

  1. MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou, W; Swann, B; Siderits, R

    2014-06-15

    Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carriedmore » out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice.« less

  2. Soaps and germicides as adjunct topical antimycotic agents on candida species implicated in vulvovaginal candidasis.

    PubMed

    Ogunshe, Adenike A O; Omotoso, Oluwatoyin A; Akindele, Titilayo M

    2011-06-01

    The study aims at evaluating the potentials of soaps and germicides/disinfectants as adjunct topical anti-vulvovaginal candidasis agents. In vitro inhibitory activities of the test agents, prepared according to the manufacturer's specification for toilet and midwifery purposes were determined using modified agar well-diffusion method. Varied susceptibility patterns were exhibited by Candida albicans (26.5%), C. glabrata (18.4%), C. pseudotropicalis (14.3%) and C. tropicalis (40.8%) implicated in vulvovaginal candidasis, indicating Crusader oil (100%), Meriko (95%), Tetmosol (84.7%) and Aloe (68.4%) as the most inhibitory soaps against the Candida strains. The in vitro inhibitory activities of the germicides and disinfectants ranged between (Dettol; 34.6% and Purit; 84.6%) for C. albicans; (Roberts; 33.3% and Purit; 83.3%) for C. glabrata; (Roberts; 21.4% and Purit; 92.9%) for C. pseudotropicalis; (Dettol; 35.0% and Purit; 87.5%) for C. tropicalis respectively. All the Candida strains were totally inhibited by the germicides and disinfectants at the second lower dilutions, except in Morigad towards C. albicans (69.2%]) C. glabrata (72.2%), C. pseudotropicalis (92.9%) and C. tropicalis (82.5%) but none of the vaginal Lactobacillus strains was inhibited by the soaps, germicides or disinfectant. About 90% of a control group indicated relief after pubic cleansing with soaps, germicides and disinfectants. Results indicatied the safety of soaps, germicides and disinfectants as potential adjunct topical cleansing-agents in cases of vaginal itching and candidasis, a common mucosal infection caused by opportunistic yeasts of the Candida genus.

  3. High-pressure synthesis, crystal structure, and magnetic properties of KSbO3-type 5d oxides K0.84OsO3 and Bi2.93Os3O11

    NASA Astrophysics Data System (ADS)

    Yuan, Yahua; Feng, Hai L.; Shi, Youguo; Tsujimoto, Yoshihiro; Belik, Alexei A.; Matsushita, Yoshitaka; Arai, Masao; He, Jianfeng; Tanaka, Masahiko; Yamaura, Kazunari

    2014-12-01

    5d Solid-state oxides K0.84OsO3 (Os5.16+; 5d 2.84) and Bi2.93Os3O11 (Os4.40+; 5d 3.60) were synthesized under high-pressure and high-temperature conditions (6 GPa and 1500-1700 °C). Their crystal structures were determined by synchrotron x-ray diffraction and their 5d electronic properties and tunnel-like structure motifs were investigated. A KSbO3-type structure with a space group of Im-3 and Pn-3 was determined for K0.84OsO3 and Bi2.93Os3O11, respectively. The magnetic and electronic transport properties of the polycrystalline compounds were compared with those obtained theoretically. It was revealed that the 5d tunnel-like structures are paramagnetic with metallic charge conduction at temperatures above 2 K. This was similar to what was observed for structurally relevant 5d oxides, including Bi3Re3O11 (Re4.33+; 5d 2.66) and Ba2Ir3O9 (Ir4.66+; 5d 4.33). The absence of long-range magnetic order seems to be common among 5d KSbO3-like oxides, regardless of the number of 5d electrons (between 2.6 and 4.3 per 5d atom).

  4. Iridates and RuCl3 - from Heisenberg antiferromagnets to potential Kitaev spin-liquids

    NASA Astrophysics Data System (ADS)

    van den Brink, Jeroen

    The observed richness of topological states on the single-electron level prompts the question what kind of topological phases can develop in more strongly correlated, many-body electron systems. Correlation effects, in particular intra- and inter-orbital electron-electron interactions, are very substantial in 3 d transition-metal compounds such as the copper oxides, but the spin-orbit coupling (SOC) is weak. In 5 d transition-metal compounds such as iridates, the interesting situation arises that the SOC and Coulomb interactions meet on the same energy scale. The electronic structure of iridates thus depends on a strong competition between the electronic hopping amplitudes, local energy-level splittings, electron-electron interaction strengths, and the SOC of the Ir 5d electrons. The interplay of these ingredients offers the potential to stabilise relatively well-understood states such as a 2D Heisenberg-like antiferromagnet in Sr2IrO4, but in principle also far more exotic ones, such a topological Kitaev quantum spin liquid, in (hyper)honeycomb iridates. I will discuss the microscopic electronic structures of these iridates, their proximity to idealized Heisenberg and Kitaev models and our contributions to establishing the physical factors that appear to have preempted the realization of quantum spin liquid phases so far and include a discussion on the 4d transition metal chloride RuCl3. Supported by SFB 1143 of the Deutsche Forschungsgemeinschaft.

  5. Excess electron is trapped in a large single molecular cage C60F60.

    PubMed

    Wang, Yin-Feng; Li, Zhi-Ru; Wu, Di; Sun, Chia-Chung; Gu, Feng-Long

    2010-01-15

    A new kind of solvated electron systems, sphere-shaped e(-)@C60F60 (I(h)) and capsule-shaped e(-)@C60F60 (D6h), in contrast to the endohedral complex M@C60, is represented at the B3LYP/6-31G(d) + dBF (diffusive basis functions) density functional theory. It is proven, by examining the singly occupied molecular orbital (SOMO) and the spin density map of e(-)@C60F60, that the excess electron is indeed encapsulated inside the C60F60 cage. The shape of the electron cloud in SOMO matches with the shape of C60F60 cage. These cage-like single molecular solvated electrons have considerably large vertical electron detachment energies VDE of 4.95 (I(h)) and 4.67 eV (D6h) at B3LYP/6-31+G(3df) + dBF level compared to the VDE of 3.2 eV for an electron in bulk water (Coe et al., Int Rev Phys Chem 2001, 20, 33) and that of 3.66 eV for e(-)@C20F20 (Irikura, J Phys Chem A 2008, 112, 983), which shows their higher stability. The VDE of the sphere-shaped e(-)@C60F60 (I(h)) is greater than that of the capsule-shaped e(-)@C60F60 (D6h), indicating that the excess electron prefers to reside in the cage with the higher symmetry to form the more stable solvated electron. It is also noticed that the cage size [7.994 (I(h)), 5.714 and 9.978 A (D6h) in diameter] is much larger than that (2.826 A) of (H2O)20- dodecahedral cluster (Khan, Chem Phys Lett 2005, 401, 85). Copyright 2009 Wiley Periodicals, Inc.

  6. Communication: Time- and space-sliced velocity map electron imaging

    NASA Astrophysics Data System (ADS)

    Lee, Suk Kyoung; Lin, Yun Fei; Lingenfelter, Steven; Fan, Lin; Winney, Alexander H.; Li, Wen

    2014-12-01

    We develop a new method to achieve slice electron imaging using a conventional velocity map imaging apparatus with two additional components: a fast frame complementary metal-oxide semiconductor camera and a high-speed digitizer. The setup was previously shown to be capable of 3D detection and coincidence measurements of ions. Here, we show that when this method is applied to electron imaging, a time slice of 32 ps and a spatial slice of less than 1 mm thick can be achieved. Each slice directly extracts 3D velocity distributions of electrons and provides electron velocity distributions that are impossible or difficult to obtain with a standard 2D imaging electron detector.

  7. Vulvar Care

    MedlinePlus

    ... products that women commonly use. These include some soaps, shower and bath products, laundry products, panty liners ... makes them feel more uncomfortable. Frequent washing with soap and other cleansing products also can increase pain ...

  8. Electronic Structure of Ytterbium-Doped Strontium Fluoroapatite: Photoemission and Photoabsorption Investigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Art J.; Van Buuren, Tony W.; Bostedt, C

    X-ray photoemission and x-ray photoabsorption were used to study the composition and the electronic structure of ytterbium-doped strontium fluoroapatite (Yb:S-FAP). High resolution photoemission measurements on the valence band electronic structure and Sr 3d, P 2p and 2s, Yb 4d and 4p, F 1s and O 1s core lines were used to evaluate the surface and near surface chemistry of this fluoroapatite. Element specific density of unoccupied electronic states in Yb:S-FAP were probed by x-ray absorption spectroscopy (XAS) at the Yb 4d (N4,5-edge), Sr 3d (M4,5-edge), P 2p (L2,3-edge), F 1s and O 1s (K-edges) absorption edges. These results provide themore » first measurements of the electronic structure and surface chemistry of this material.« less

  9. Washing away your (good or bad) luck: physical cleansing affects risk-taking behavior.

    PubMed

    Xu, Alison Jing; Zwick, Rami; Schwarz, Norbert

    2012-02-01

    Many superstitious practices entail the belief that good or bad luck can be "washed away." Consistent with this belief, participants who recalled (Experiment 1) or experienced (Experiment 2) an episode of bad luck were more willing to take risk after having as opposed to not having washed their hands, whereas participants who recalled or experienced an episode of good luck were less willing to take risk after having as opposed to not having washed their hands. Thus, the psychological effects of physical cleansings extend beyond the domain of moral judgment and are independent of people's motivation: incidental washing not only removes undesirable traces of the past (such as bad luck) but also desirable ones (such as good luck), which people would rather preserve.

  10. Cleansing the world of the germ of laziness: hygiene, sanitation, and the Javanese population in Suriname.

    PubMed

    Hoefte, Rosemarijn

    2014-01-01

    In 1915 the Rockefeller Foundation took its hookworm eradication campaign to Suriname, but was soon disappointed because of opposition from its main target group: the Javanese. Moreover, authorities and planters objected to the construction of latrines because of the costs and their belief that the Javanese were "unhygienic". In describing the labor migration from Java to Suriname, I show that this "lack of hygiene" was closely related to the system's organization. I argue that uncleanliness was the consequence of harmful socio-economic and ecological conditions. Secondly I suggest that even though the Foundation did not manage to cleanse Suriname of hookworm, its educational efforts, its emphasis on prevention, and its training of local health workers probably had more impact than Rockefeller officials thought.

  11. National Athletic Trainers' Association Position Statement: Management of Acute Skin Trauma

    PubMed Central

    Beam, Joel W.; Buckley, Bernadette; Holcomb, William R.; Ciocca, Mario

    2016-01-01

    Objective: To present recommendations for the cleansing, debridement, dressing, and monitoring of acute skin trauma in patients. Background: Acute skin trauma is common during participation in athletic and recreational activities. Clinical decisions and intervention protocols after injury vary among athletic trainers and are often based on ritualistic practices. An understanding of cleansing, debridement, and dressing techniques; clinical features of infection and adverse reactions; and monitoring of acute skin trauma is critical for certified athletic trainers and other allied health and medical professionals to create a local wound environment that promotes healing and lessens the risk of complications. Recommendations: These guidelines are intended to provide the certified athletic trainer and others participating in athletic health care with specific knowledge about and recommendations for the management of acute skin trauma. PMID:28092169

  12. National Athletic Trainers' Association Position Statement: Management of Acute Skin Trauma.

    PubMed

    Beam, Joel W; Buckley, Bernadette; Holcomb, William R; Ciocca, Mario

    2016-12-01

      To present recommendations for the cleansing, debridement, dressing, and monitoring of acute skin trauma in patients.   Acute skin trauma is common during participation in athletic and recreational activities. Clinical decisions and intervention protocols after injury vary among athletic trainers and are often based on ritualistic practices. An understanding of cleansing, debridement, and dressing techniques; clinical features of infection and adverse reactions; and monitoring of acute skin trauma is critical for certified athletic trainers and other allied health and medical professionals to create a local wound environment that promotes healing and lessens the risk of complications.   These guidelines are intended to provide the certified athletic trainer and others participating in athletic health care with specific knowledge about and recommendations for the management of acute skin trauma.

  13. Electron-stimulated reactions in nanoscale water films adsorbed on α-Al 2 O 3 (0001)

    DOE PAGES

    Petrik, Nikolay G.; Kimmel, Greg A.

    2018-01-01

    100 eV electrons are stopped in the H 2 O portion of the isotopically-layered nanoscale film on α-Al 2 O 3 (0001) but D 2 is produced at the D 2 O/alumina interface by mobile electronic excitations and/or hydronium ions.

  14. 3D structure of individual nanocrystals in solution by electron microscopy

    DOE PAGES

    Park, Jungwok; Elmlund, Hans; Ercius, Peter; ...

    2015-07-17

    Here, knowledge about the synthesis, growth mechanisms, and physical properties of colloidal nanoparticles has been limited by technical impediments. We introduce a method for determining three-dimensional (3D) structures of individual nanoparticles in solution. We combine a graphene liquid cell, high-resolution transmission electron microscopy, a direct electron detector, and an algorithm for single-particle 3D reconstruction originally developed for analysis of biological molecules. This method yielded two 3D structures of individual platinum nanocrystals at near-atomic resolution. Because our method derives the 3D structure from images of individual nanoparticles rotating freely in solution, it enables the analysis of heterogeneous populations of potentially unorderedmore » nanoparticles that are synthesized in solution, thereby providing a means to understand the structure and stability of defects at the nanoscale.« less

  15. Nanoparticle imaging. 3D structure of individual nanocrystals in solution by electron microscopy.

    PubMed

    Park, Jungwon; Elmlund, Hans; Ercius, Peter; Yuk, Jong Min; Limmer, David T; Chen, Qian; Kim, Kwanpyo; Han, Sang Hoon; Weitz, David A; Zettl, A; Alivisatos, A Paul

    2015-07-17

    Knowledge about the synthesis, growth mechanisms, and physical properties of colloidal nanoparticles has been limited by technical impediments. We introduce a method for determining three-dimensional (3D) structures of individual nanoparticles in solution. We combine a graphene liquid cell, high-resolution transmission electron microscopy, a direct electron detector, and an algorithm for single-particle 3D reconstruction originally developed for analysis of biological molecules. This method yielded two 3D structures of individual platinum nanocrystals at near-atomic resolution. Because our method derives the 3D structure from images of individual nanoparticles rotating freely in solution, it enables the analysis of heterogeneous populations of potentially unordered nanoparticles that are synthesized in solution, thereby providing a means to understand the structure and stability of defects at the nanoscale. Copyright © 2015, American Association for the Advancement of Science.

  16. 3D structure of individual nanocrystals in solution by electron microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Jungwok; Elmlund, Hans; Ercius, Peter

    Here, knowledge about the synthesis, growth mechanisms, and physical properties of colloidal nanoparticles has been limited by technical impediments. We introduce a method for determining three-dimensional (3D) structures of individual nanoparticles in solution. We combine a graphene liquid cell, high-resolution transmission electron microscopy, a direct electron detector, and an algorithm for single-particle 3D reconstruction originally developed for analysis of biological molecules. This method yielded two 3D structures of individual platinum nanocrystals at near-atomic resolution. Because our method derives the 3D structure from images of individual nanoparticles rotating freely in solution, it enables the analysis of heterogeneous populations of potentially unorderedmore » nanoparticles that are synthesized in solution, thereby providing a means to understand the structure and stability of defects at the nanoscale.« less

  17. Strain effects on the electronic properties in δ-doped oxide superlattices

    NASA Astrophysics Data System (ADS)

    You, Jeong Ho; Lee, Jun Hee; Okamoto, Satoshi; Cooper, Valentino; Lee, Ho Nyung

    2015-03-01

    Strain effects on the electronic properties of (LaTiO3)1/(SrTiO3)N superlattices were investigated using density functional theory. Under biaxial in-plane strain within the range of -5% ≤ ɛ// ≤ 5%, the dxy orbital electrons are highly localized at the interfaces whereas the dyz and dxz orbital electrons are more distributed in the SrTiO3 (STO) spacer layers. For STO thickness N ≥ 3 unit cells (u.c.), the dxy orbital electrons form two-dimensional (2D) electron gases (2DEGs). The quantized energy levels of the 2DEG are insensitive to the STO spacer thickness, but are strongly dependent on the applied biaxial in-plane strain. As the in-plane strain changes from compressive to tensile, the quantized energy levels of the dxy orbitals decrease thereby creating more states with 2D character. In contrast to the dxy orbital, the dyz and dxz orbitals always have three-dimensional (3D) transport characteristics and their energy levels increase as the strain changes from compressive to tensile. Since the charge densities in the dxy orbital and the dyz and dxz orbitals respond to biaxial in-plane strain in an opposite way, the transport dimensionality of the majority carriers can be controlled between 2D and 3D by applying biaxial in-plane strain.

  18. Inverse Perovskites - A New Platform For 3D Dirac Electron Physics

    NASA Astrophysics Data System (ADS)

    Rost, A. W.; Kim, J.; Shota, S.; Hayama, K.; Abdolazimi, V.; Bruin, J. A. N.; Muehle, C.; Schnyder, A.; Yaresko, A. N.; Nuss, J.; Takagi, H.

    3D Dirac semimetals show a wealth of phenomena including ultrahigh mobility, extreme transverse magnetoresistance and potential for negative longitudinal magnetoresistance. Furthermore, by introducing a gap these are often found to be topological crystalline insulators. Here, I will introduce our experiments on a new family of 3D Dirac materials - the inverse perovskites A3BO (A =Ca,Sr,Eu/B =Pb,Sn). These open up the possibility to chemically control the properties of Dirac electrons including (i) the anisotropy of the Dirac dispersion, (ii) role of spin orbit coupling, and (iii) magnetism. Our physical property measurements show all (Ca/Sr)3(Pb/Sn)O compounds host Dirac electrons at the Fermi energy with no other bands crossing EF. Quantum oscillations unveil small Fermi surfaces (frequencies <5 T) and light carriers (<0.02 me) only consistent with Dirac electrons. With the successful synthesis of Sr3Pb0.5Sn0.5O this group of materials therefore offers a unique chemical control over the physical properties of 3D Dirac electrons. Crucially, Eu3(Pb/Sn)O compounds allow for the introduction of magnetism. I will discuss the implications of this in particular with respect to surface states in these topological crystalline insulators.

  19. Recent advances in electron tomography: TEM and HAADF-STEM tomography for materials science and semiconductor applications.

    PubMed

    Kübel, Christian; Voigt, Andreas; Schoenmakers, Remco; Otten, Max; Su, David; Lee, Tan-Chen; Carlsson, Anna; Bradley, John

    2005-10-01

    Electron tomography is a well-established technique for three-dimensional structure determination of (almost) amorphous specimens in life sciences applications. With the recent advances in nanotechnology and the semiconductor industry, there is also an increasing need for high-resolution three-dimensional (3D) structural information in physical sciences. In this article, we evaluate the capabilities and limitations of transmission electron microscopy (TEM) and high-angle-annular-dark-field scanning transmission electron microscopy (HAADF-STEM) tomography for the 3D structural characterization of partially crystalline to highly crystalline materials. Our analysis of catalysts, a hydrogen storage material, and different semiconductor devices shows that features with a diameter as small as 1-2 nm can be resolved in three dimensions by electron tomography. For partially crystalline materials with small single crystalline domains, bright-field TEM tomography provides reliable 3D structural information. HAADF-STEM tomography is more versatile and can also be used for high-resolution 3D imaging of highly crystalline materials such as semiconductor devices.

  20. 3D Printing of Shape Memory Polymers for Flexible Electronic Devices.

    PubMed

    Zarek, Matt; Layani, Michael; Cooperstein, Ido; Sachyani, Ela; Cohn, Daniel; Magdassi, Shlomo

    2016-06-01

    The formation of 3D objects composed of shape memory polymers for flexible electronics is described. Layer-by-layer photopolymerization of methacrylated semicrystalline molten macromonomers by a 3D digital light processing printer enables rapid fabrication of complex objects and imparts shape memory functionality for electrical circuits. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Hand Washing Induces a Clean Slate Effect in Moral Judgments: A Pupillometry and Eye-Tracking Study

    PubMed Central

    Kaspar, Kai; Krapp, Vanessa; König, Peter

    2015-01-01

    Physical cleansing is commonly understood to protect us against physical contamination. However, recent studies showed additional effects on moral judgments. Under the heading of the “Macbeth effect” direct links between bodily cleansing and one’s own moral purity have been demonstrated. Here we investigate (1) how moral judgments develop over time and how they are altered by hand washing, (2) whether changes in moral judgments can be explained by altered information sampling from the environment, and (3) whether hand washing affects emotional arousal. Using a pre-post control group design, we found that morality ratings of morally good and bad scenes acquired more extreme values in the control group over time, an effect that was fully counteracted by intermediate hand washing. This result supports the notion of a clean slate effect by hand washing. Thereby, eye-tracking data did not uncover differences in eye movement behavior that may explain differences in moral judgments. Thus, the clean slate effect is not due to altered information sampling from the environment. Finally, compared to the control group, pupil diameter decreased after hand washing, thus demonstrating a direct physiological effect. The results shed light on the physiological mechanisms behind this type of embodiment phenomenon. PMID:25994083

  2. Conservation of water for washing beef heads at harvest.

    PubMed

    DeOtte, R E; Spivey, K S; Galloway, H O; Lawrence, T E

    2010-03-01

    The objective of this research was to develop methods to conserve water necessary to cleanse beef heads prior to USDA-FSIS inspection. This was to be accomplished by establishing a baseline for the minimum amount of water necessary to adequately wash a head and application of image analysis to provide an objective measure of head cleaning. Twenty-one beef heads were manually washed during the harvest process. An average 18.75 L (2.49 SD) and a maximum of 23.88 L were required to cleanse the heads to USDA-FSIS standards. Digital images were captured before and after manual washing then evaluated for percentage red saturation using commercially available image analysis software. A decaying exponential curve extracted from these data indicated that as wash water increased beyond 20 L the impact on red saturation decreased. At 4 sigma from the mean of 18.75 L, red saturation is 16.0 percent, at which logistic regression analysis indicates 99.994 percent of heads would be accepted for inspection, or less than 1 head in 15,000 would be rejected. Reducing to 3 sigma would increase red saturation to 27.6 percent, for which 99.730 percent of heads likely would be accepted (less than 1 in 370 would be rejected). Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Non-fragrance allergens in specific cosmetic products.

    PubMed

    Travassos, Ana Rita; Claes, Lieve; Boey, Lies; Drieghe, Jacques; Goossens, An

    2011-11-01

    Reports about the nature of the ingredients responsible for allergic contact dermatitis caused by specific cosmetic products are scarce. Between January 2000 and December 2010, the specific cosmetic products having caused allergic contact dermatitis, as well as the individual allergenic cosmetic ingredients present in them, were recorded by use of a standardized form. Among 11 different categories of cosmetic product, skin care products, followed by hair care and body-cleansing products, were most often involved. The presence of the allergenic ingredient(s) in a specific cosmetic product was confirmed according to the ingredient label in 959 of 1448 records. Six hundred and twenty-one of 959 concerned non-fragrance components, preservatives being responsible for 58% of them. Reactions to formaldehyde and formaldehyde-releasers were most often correlated with body-cleansing products, particularly 2-bromo-2-nitropropane-1,3-diol and skin care products. They were followed by the methylchloroisothiazolinone/methylisothiazolinone mixture, most frequently found as allergens in hair care and intimate hygiene products, and facial cleansers (in the last category together with diazolidinyl urea). Octocrylene was by far the most frequent (photo)allergen in sun care products. This study provides information on the presence and frequency of allergens in specific causal cosmetic products. © 2011 John Wiley & Sons A/S.

  4. Case series: PTSD symptoms in adolescent survivors of "ethnic cleansing." Results from a 1-year follow-up study.

    PubMed

    Becker, D F; Weine, S M; Vojvoda, D; McGlashan, T H

    1999-06-01

    The authors describe the psychiatric sequelae of "ethnic cleansing" in adolescent Bosnian refugees, via a 1-year follow-up study. Ten Bosnian adolescent refugees from the war in Bosnia-Herzegovina received a baseline assessment within the first year after their resettlement and a follow-up assessment 1 year later. Evaluations included an assessment scale for posttraumatic stress disorder (PTSD) symptom severity. At baseline, 3 subjects met criteria for PTSD. At follow-up, this diagnosis persisted in none of these subjects, though 1 subject met criteria at follow-up only. For the group, mean PTSD severity scores at baseline and at follow-up were 8.9 and 4.0, respectively. At baseline, reexperiencing symptoms were present 43% of the time, avoidance symptoms were present 33% of the time, and hyperarousal symptoms were present 33% of the time; at follow-up, these proportions were 35%, 16%, and 18%, respectively. Overall, rates of PTSD symptoms diminished during the 1-year follow-up interval, suggesting that they may be transient and not representative of enduring psychopathology. This finding may reflect the relative resiliency of adolescents, as well as a variety of factors that facilitated adaptation in our particular group of adolescent refugees.

  5. Asymmetric 3d Electronic Structure for Enhanced Oxygen Evolution Catalysis.

    PubMed

    Liu, Yang; Yin, Shibin; Shen, Pei Kang

    2018-06-27

    The oxygen evolution reaction (OER) is an essential process for renewable energy, and designing a bifunctional oxygen electrocatalyst with high catalytic performance plays a significant role. In this work, FeS, Ni 3 S 2 , Fe 5 Ni 4 S 8 , and N, O, S-doped meshy carbon base were successfully synthesized. The sample containing Fe 5 Ni 4 S 8 exhibited excellent OER performance. The density functional theory calculations indicate that the partial density of states for 3d electrons (3d-PDOS) of Fe and Ni atoms are changed from monometallic sulfide to bimetallic sulfide at the sulfur vacancy. The asymmetric 3d electronic structure optimizes the 3d-PDOS of Fe and Ni atoms, and leads to an enhanced OER activity. This work provides a new strategy to prepare a low-cost electrocatalyst for oxygen evolution with high-efficiency.

  6. Growth and Transport Studies of LaTiO3 / KTaO3 Heterostructures

    NASA Astrophysics Data System (ADS)

    Zou, K.; Walker, F. J.; Ahn, C. H.

    2014-03-01

    Perovskite oxide heterostructures provide a rich platform for exploring emergent electronic properties, such as 2D electron gases (2DEGs) at interfaces. In this talk, we present results on the growth of LaTiO3 / KTaO3 heterostructures by molecular beam epitaxy and subsequent measurements of transport properties. Although both oxide materials are insulating in the bulk, metallic conduction is observed from T = 2 - 300 K. We achieve a room temperature carrier mobility of ~ 25 cm2 /Vs at a carrier density of ~ 1014 /cm2. By comparison, 2DEGs in LaTiO3 / SrTiO3 and LaAlO3 / SrTiO3 have lower carrier mobility, but the same carrier density. We attribute some of the increase in mobility to the smaller band effective mass of the Ta 4d electrons compared to the Ti 3d electrons.

  7. 3D printed electromagnetic transmission and electronic structures fabricated on a single platform using advanced process integration techniques

    NASA Astrophysics Data System (ADS)

    Deffenbaugh, Paul Issac

    3D printing has garnered immense attention from many fields including in-office rapid prototyping of mechanical parts, outer-space satellite replication, garage functional firearm manufacture, and NASA rocket engine component fabrication. 3D printing allows increased design flexibility in the fabrication of electronics, microwave circuits and wireless antennas and has reached a level of maturity which allows functional parts to be printed. Much more work is necessary in order to perfect the processes of 3D printed electronics especially in the area of automation. Chapter 1 shows several finished prototypes of 3D printed electronics as well as newly developed techniques in fabrication. Little is known about the RF and microwave properties and applications of the standard materials which have been developed for 3D printing. Measurement of a wide variety of materials over a broad spectrum of frequencies up to 10 GHz using a variety of well-established measurement methods is performed throughout chapter 2. Several types of high frequency RF transmission lines are fabricated and valuable model-matched data is gathered and provided in chapter 3 for future designers' use. Of particular note is a fully 3D printed stripline which was automatically fabricated in one process on one machine. Some core advantages of 3D printing RF/microwave components include rapid manufacturing of complex, dimensionally sensitive circuits (such as antennas and filters which are often iteratively tuned) and the ability to create new devices that cannot be made using standard fabrication techniques. Chapter 4 describes an exemplary fully 3D printed curved inverted-F antenna.

  8. Split-dose administration of a dual-action, low-volume bowel cleanser for colonoscopy: the SEE CLEAR I study.

    PubMed

    Rex, Douglas K; Katz, Philip O; Bertiger, Gerald; Vanner, Stephen; Hookey, Lawrence C; Alderfer, Vivian; Joseph, Raymond E

    2013-07-01

    New bowel cleansers for colonoscopy that lead to improved efficacy, safety, and tolerability are needed. This study evaluated a nonphosphate, dual-action, low-volume, orange-flavored preparation containing sodium picosulfate and magnesium citrate (P/MC). Multicenter, assessor-blinded, randomized, noninferiority study. University hospitals, academic medical centers, and private clinics across the United States. Adults preparing for colonoscopy. P/MC versus 2 L of polyethylene glycol solution (2L PEG-3350) and two 5-mg bisacodyl tablets. This phase 3 study investigated the efficacy, safety, and tolerability of split-dose administration of P/MC versus day-before dosing of 2L PEG-3350 and two 5-mg bisacodyl tablets (SEE CLEAR I study). Efficacy was evaluated by using the Aronchick and Ottawa scales; noninferiority and superiority analyses were performed. Safety was assessed by monitoring adverse events (AEs). Tolerability was measured via a patient questionnaire. The intent-to-treat population consisted of 601 patients who self-administered P/MC (n = 304) or 2L PEG-3350 and bisacodyl tablets (n = 297). P/MC was superior to 2L PEG-3350 and bisacodyl tablets in overall colon cleansing (84.2% vs 74.4%; 1-sided 97.5% confidence interval [CI], 3.4) (Aronchick scores of excellent or good) and in cleansing of the ascending (89.5% vs 78.8%; 1-sided 97.5% CI, 4.9), mid (transverse and descending) (92.4% vs 85.9%; 1-sided 97.5% CI, 1.6), and rectosigmoid (92.4% vs 87.2%; 1-sided 97.5% CI, 0.4) segments of the colon (Ottawa scores of excellent, good, or fair). Commonly reported AEs related to the bowel preparations were nausea, vomiting, headache, and chills. Patient-reported tolerability, including ease of consumption and taste, was significantly higher for P/MC than 2L PEG-3350 and bisacodyl tablets (P < .0001). Because of differences in administration and volume of the bowel preparations, the study was designed to be a single-assessor, blinded study. The bowel-cleansing effects and patient acceptability of split-dose P/MC were superior to day-before dosing with 2L PEG-3350 and bisacodyl tablets. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  9. State-resolved three-dimensional electron-momentum correlation in nonsequential double ionization of benzene

    NASA Astrophysics Data System (ADS)

    Winney, Alexander H.; Lin, Yun Fei; Lee, Suk Kyoung; Adhikari, Pradip; Li, Wen

    2016-03-01

    We report state-resolved electron-momentum correlation measurement of strong-field nonsequential double ionization in benzene. With a novel coincidence detection apparatus, highly efficient triple coincidence (electron-electron dication) and quadruple coincidence (electron-electron-cation-cation) are used to resolve the final ionic states and to characterize three-dimensional (3D) electron-momentum correlation. The primary states associated with dissociative and nondissociative dications are assigned. A 3D momentum anticorrelation is observed for the electrons in coincidence with dissociative benzene dication states whereas such a correlation is absent for nondissociative dication states.

  10. Electron Tomography: A Three-Dimensional Analytic Tool for Hard and Soft Materials Research.

    PubMed

    Ercius, Peter; Alaidi, Osama; Rames, Matthew J; Ren, Gang

    2015-10-14

    Three-dimensional (3D) structural analysis is essential to understand the relationship between the structure and function of an object. Many analytical techniques, such as X-ray diffraction, neutron spectroscopy, and electron microscopy imaging, are used to provide structural information. Transmission electron microscopy (TEM), one of the most popular analytic tools, has been widely used for structural analysis in both physical and biological sciences for many decades, in which 3D objects are projected into two-dimensional (2D) images. In many cases, 2D-projection images are insufficient to understand the relationship between the 3D structure and the function of nanoscale objects. Electron tomography (ET) is a technique that retrieves 3D structural information from a tilt series of 2D projections, and is gradually becoming a mature technology with sub-nanometer resolution. Distinct methods to overcome sample-based limitations have been separately developed in both physical and biological science, although they share some basic concepts of ET. This review discusses the common basis for 3D characterization, and specifies difficulties and solutions regarding both hard and soft materials research. It is hoped that novel solutions based on current state-of-the-art techniques for advanced applications in hybrid matter systems can be motivated. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Electron Tomography: A Three-Dimensional Analytic Tool for Hard and Soft Materials Research

    PubMed Central

    Alaidi, Osama; Rames, Matthew J.

    2016-01-01

    Three-dimensional (3D) structural analysis is essential to understand the relationship between the structure and function of an object. Many analytical techniques, such as X-ray diffraction, neutron spectroscopy, and electron microscopy imaging, are used to provide structural information. Transmission electron microscopy (TEM), one of the most popular analytic tools, has been widely used for structural analysis in both physical and biological sciences for many decades, in which 3D objects are projected into two-dimensional (2D) images. In many cases, 2D-projection images are insufficient to understand the relationship between the 3D structure and the function of nanoscale objects. Electron tomography (ET) is a technique that retrieves 3D structural information from a tilt series of 2D projections, and is gradually becoming a mature technology with sub-nanometer resolution. Distinct methods to overcome sample-based limitations have been separately developed in both physical and biological science, although they share some basic concepts of ET. This review discusses the common basis for 3D characterization, and specifies difficulties and solutions regarding both hard and soft materials research. It is hoped that novel solutions based on current state-of-the-art techniques for advanced applications in hybrid matter systems can be motivated. PMID:26087941

  12. Gallbladder Cleanse: A "Natural" Remedy for Gallstones?

    MedlinePlus

    ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization and proceeds from Web advertising help support our mission. Mayo Clinic does not ...

  13. Runaway electron production in DIII-D killer pellet experiments, calculated with the CQL3D/KPRAD model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harvey, R. W.; Chan, V. S.; Chiu, S. C.

    2000-11-01

    Runaway electrons are calculated to be produced during the rapid plasma cooling resulting from ''killer pellet'' injection experiments, in general agreement with observations in the DIII-D [J. L. Luxon , Plasma Physics and Controlled Nuclear Fusion Research 1986 (International Atomic Energy Agency, Vienna, 1987), Vol. I, p. 159] tokamak. The time-dependent dynamics of the kinetic runaway distributions are obtained with the CQL3D [R. W. Harvey and M. G. McCoy, ''The CQL3D Code,'' in Proceedings of the IAEA Technical Committee Meeting on Numerical Modeling, Montreal, 1992 (International Atomic Energy Agency, Vienna, 1992), p. 489] collisional Fokker--Planck code, including the effect ofmore » small and large angle collisions and stochastic magnetic field transport losses. The background density, temperature, and Z{sub eff} are evolved according to the KPRAD [D. G. Whyte and T. E. Evans , in Proceedings of the 24th European Conference on Controlled Fusion and Plasma Physics, Berchtesgaden, Germany (European Physical Society, Petit-Lancy, 1997), Vol. 21A, p. 1137] deposition and radiation model of pellet--plasma interactions. Three distinct runway mechanisms are apparent: (1) prompt ''hot-tail runaways'' due to the residual hot electron tail remaining from the pre-cooling phase, (2) ''knock-on'' runaways produced by large-angle Coulomb collisions on existing high energy electrons, and (3) Dreicer ''drizzle'' runaway electrons due to diffusion of electrons up to the critical velocity for electron runaway. For electron densities below {approx}1x10{sup 15}cm{sup -3}, the hot-tail runaways dominate the early time evolution, and provide the seed population for late time knock-on runaway avalanche. For small enough stochastic magnetic field transport losses, the knock-on production of electrons balances the losses at late times. For losses due to radial magnetic field perturbations in excess of {approx}0.1% of the background field, i.e., {delta}B{sub r}/B{>=}0.001, the losses prevent late-time electron runaway.« less

  14. Ultrathin nickel hydroxide on carbon coated 3D-porous copper structures for high performance supercapacitors.

    PubMed

    Kang, Kyeong-Nam; Kim, Ik-Hee; Ramadoss, Ananthakumar; Kim, Sun-I; Yoon, Jong-Chul; Jang, Ji-Hyun

    2018-01-03

    An ultrathin nickel hydroxide layer electrodeposited on a carbon-coated three-dimensional porous copper structure (3D-C/Cu) is suggested as an additive and binder-free conductive electrode with short electron path distances, large electrochemical active sites, and improved structural stability, for high performance supercapacitors. The 3D-porous copper structure (3D-Cu) provides high electrical conductivity and facilitates electron transport between the Ni(OH) 2 active materials and the current collector of the Ni-plate. A carbon coating was applied to the 3D-Cu to prevent the oxidation of Cu, without degrading the electron transport behavior of the 3D-Cu. The 3D-Ni(OH) 2 /C/Cu exhibited a high specific capacitance of 1860 F g -1 at 1 A g -1 , and good cycling performance, with an 86.5% capacitance retention after 10 000 cycles. When tested in a two-electrode system, an asymmetric supercapacitor exhibited an energy density of 147.9 W h kg -1 and a power density of 37.0 kW kg -1 . These results open a new area of ultrahigh-performance supercapacitors, supported by 3D-Cu electrodes.

  15. Polarization Dependent Bulk-sensitive Valence Band Photoemission Spectroscopy and Density Functional Theory Calculations: Part I. 3d Transition Metals

    NASA Astrophysics Data System (ADS)

    Ueda, Shigenori; Hamada, Ikutaro

    2017-12-01

    The X-ray polarization dependent valence band HAXPES spectra of 3d transition metals (TMs) of Ti-Zn were measured to investigate the orbital resolved electronic structures by utilizing that the fact the photoionization cross-section of the atomic orbitals strongly depends on the experimental geometry. We have calculated the HAXPES spectra, which correspond to the cross-section weighted densities of states (CSW-DOSs), where the DOSs were obtained by the density functional theory calculations, and we have determined the relative photoionization cross-sections of the 4s and 4p orbitals to the 3d orbital in the 3d TMs. The experimentally obtained bulk-sensitive 3d and 4s DOSs were good agreement with the calculated DOSs in Ti, V, Cr, and Cu. In contrast, the deviations between the experimental and calculated 3d DOSs for Mn, Fe, Co, Ni were found, suggesting that the electron correlation plays an important role in the electronic structures for these materials.

  16. Tunable Magneto-electric Subbands in Oxide Electron Waveguides

    NASA Astrophysics Data System (ADS)

    Cheng, Guanglei; Annadi, Anil; Lu, Shicheng; Lee, Hyungwoo; Lee, Jungwoo; Eom, Chang-Beom; Huang, Mengchen; Irvin, Patrick; Levy, Jeremy

    Strontium titanate-based complex-oxide interfaces hold great promise for exploring new correlated electron physics and applications in quantum technologies. Previous reports show electron mobility can be greatly enhanced in 1D, while the 2D interface can contain 1D channels due to the presence of ferroelastic domains. In addition, carrier density measurements at the 2D interface by Shubnikov-de Haas (SdH) oscillations and Hall effect reveal a large discrepancy. Here we fabricate quasi-1D electron waveguides at the LaAlO3/SrTiO3 (LAO/STO) interface to locally probe the interface. The conductance of the waveguides is fully quantized, and the corresponding magneto-electric subbands can be depopulated by increasing the magnetic field. The 2D carrier densities (1012 cm-2) extracted from magnetic depopulation are consistent with measurements by SdH oscillations at the 2D interface. Our results show that magneto-electric subbands of quasi-1D electron waveguides can reproduce known SdH signatures without discrepancies in electron density, and suggest that 2D SdH measurements may also arise from quasi-1D channels. We gratefully acknowledge financial support from AFOSR (FA9550-12-1- 0057 (JL) and FA9550-12-1-0342 (CBE)), ONR N00014-15-1-2847 (JL), and NSF DMR-1234096 (CBE).

  17. Study of plasma meniscus formation and beam halo in negative ion source using the 3D3VPIC model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishioka, S.; Goto, I.; Hatayama, A.

    2015-04-08

    In this paper, the effect of the electron confinement time on the plasma meniscus and the fraction of the beam halo is investigated by 3D3V-PIC (three dimension in real space and three dimension in velocity space) (Particle in Cell) simulation in the extraction region of negative ion source. The electron confinement time depends on the characteristic time of electron escape along the magnetic field as well as the characteristic time of diffusion across the magnetic field. Our 3D3V-PIC results support the previous result by 2D3V-PIC results i.e., it is confirmed that the penetration of the plasma meniscus becomes deep intomore » the source plasma region when the effective confinement time is short.« less

  18. Novel Electronic Behavior Driving NdNiO 3 Metal-Insulator Transition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upton, M. H.; Choi, Yongseong; Park, Hyowon

    2015-07-01

    We present evidence that the metal-insulator transition (MIT) in a tensile-strained NdNiO3 (NNO) film is facilitated by a redistribution of electronic density and that it neither requires Ni charge disproportionation nor a symmetry change [U. Staub et al., Phys. Rev. Lett. 88, 126402 (2002); R. Jaramillo et al., Nat. Phys. 10, 304 (2014)]. Given that epitaxial tensile strain in thin NNO films induces preferential occupancy of the e(g) d(x2-y2) orbital we propose that the larger transfer integral of this orbital state with the O 2p orbital state mediates a redistribution of electronic density from the Ni atom. A decrease inmore » the Ni d(x2-y2) orbital occupation is directly observed by resonant inelastic x-ray scattering below the MIT temperature. Furthermore, an increase in the Nd charge occupancy is measured by x-ray absorption at the Nd L-3 edge. Both spin-orbit coupling and crystal field effects combine to break the degeneracy of the Nd 5d states, shifting the energy of the Nd e(g) d(x2-y2) orbit towards the Fermi level, allowing the A site to become an active acceptor during the MIT. This work identifies the relocation of electrons from the Ni 3d to the Nd 5d orbitals across the MIT. We propose that the insulating gap opens between the Ni 3d and O 2p states, resulting from Ni 3d electron localization. The transition seems to be neither a purely Mott-Hubbard transition nor a simple charge transfer.« less

  19. A novel permeabilization protocol to obtain intracellular 3D immunolabeling for electron tomography.

    PubMed

    Jiménez, Nuria; Post, Jan A

    2014-01-01

    Electron tomography (ET) is a very important high-resolution tool for 3D imaging in cell biology. By combining the technique with immunolabeling, ET can provide essential insights into both cellular architecture and dynamics. We recently developed a protocol to achieve 3D immunolabeling of intracellular antigens without the need for uncontrolled permeabilization steps that cause random, extensive cell membrane disruption. Here we describe this novel method based on well-controlled permeabilization by targeted laser cell perforation. Mechanical permeabilization of the plasma membrane can be applied at specific sites without affecting other parts of the plasma membrane and intracellular membranes. Despite the relatively small opening created in the plasma membrane, the method allows specific 3D immunolocalization of cytoplasmic antigens in cultured cells by a pre-embedment protocol. The approach is unique and leads to a superior ultrastructural preservation for transmission electron microscopy and electron tomography.

  20. Determination of the effective anticandidal concentration of denture cleanser tablets on some denture base resins

    PubMed Central

    Hayran, Yeliz; Sarikaya, Işıl; Aydin, Ali; Tekin, Yadel Hazır

    2018-01-01

    Abstract Objective Although the effectiveness of chemical cleansing against Candida albicans biofilm has been shown, the effective concentration of denture cleanser tablets has not been studied. The aim of this study was to assess the effect of three denture materials against Candida albicans biofilm and to determine effective concentrations of denture cleanser tablets. Material and methods The surface-roughness of Acron-hi™, QC-20™ and Deflex™ (n=45 per resin) resins was standardized by using a profilometer and their contact angle or surface free energy was calculated. C. albicans biofilm was formed on all three resins and were treated with Polident 3 min™, Corega™ and Fittydent™ cleanser solutions at various concentrations and both resin-biofilm and cleanser-biofilm interest were determined by using a MTT protocol according to the European Committee on Antimicrobial Susceptibility Testing's antifungal susceptibility testing (AFST-EUCAST). Scanning electron microscopy was used to compare the efficacy of different resin materials against C. albicans biofilm. Anticandidal activity and surface free energy statistical parameters were calculated by using 3-way and 1-way ANOVA, respectively (p<0.05). Results Polident 3 min™ and Corega™ tablets significantly inhibited (p<0.05) the proliferation of C. albicans against all denture resins at 27-37 mg/mL. Scanning electron microscopy results indicated that there was no significant difference among resin specimens regarding biofilm formation on dentures. We failed to find a significant relationship between surface free energy and the anticandidal effect of resin types. However, the polarity value of the resins was statistically associated with their anticandidal activity. Conclusions The polarity of the resins, the concentrations of tablets and the chemical content of the cleanser may directly affect C. albicans biofilm formations. Polident 3 min™ and Corega™ tablets should be suggested for patients who use any denture resin types, whereas the Fittydent™ tablet should only be proposed for those who use Deflex™, when two tablets are dropped into 150 mL water. PMID:29364341

  1. High-purity 3D nano-objects grown by focused-electron-beam induced deposition.

    PubMed

    Córdoba, Rosa; Sharma, Nidhi; Kölling, Sebastian; Koenraad, Paul M; Koopmans, Bert

    2016-09-02

    To increase the efficiency of current electronics, a specific challenge for the next generation of memory, sensing and logic devices is to find suitable strategies to move from two- to three-dimensional (3D) architectures. However, the creation of real 3D nano-objects is not trivial. Emerging non-conventional nanofabrication tools are required for this purpose. One attractive method is focused-electron-beam induced deposition (FEBID), a direct-write process of 3D nano-objects. Here, we grow 3D iron and cobalt nanopillars by FEBID using diiron nonacarbonyl Fe2(CO)9, and dicobalt octacarbonyl Co2(CO)8, respectively, as starting materials. In addition, we systematically study the composition of these nanopillars at the sub-nanometer scale by atom probe tomography, explicitly mapping the homogeneity of the radial and longitudinal composition distributions. We show a way of fabricating high-purity 3D vertical nanostructures of ∼50 nm in diameter and a few micrometers in length. Our results suggest that the purity of such 3D nanoelements (above 90 at% Fe and above 95 at% Co) is directly linked to their growth regime, in which the selected deposition conditions are crucial for the final quality of the nanostructure. Moreover, we demonstrate that FEBID and the proposed characterization technique not only allow for growth and chemical analysis of single-element structures, but also offers a new way to directly study 3D core-shell architectures. This straightforward concept could establish a promising route to the design of 3D elements for future nano-electronic devices.

  2. High-purity 3D nano-objects grown by focused-electron-beam induced deposition

    NASA Astrophysics Data System (ADS)

    Córdoba, Rosa; Sharma, Nidhi; Kölling, Sebastian; Koenraad, Paul M.; Koopmans, Bert

    2016-09-01

    To increase the efficiency of current electronics, a specific challenge for the next generation of memory, sensing and logic devices is to find suitable strategies to move from two- to three-dimensional (3D) architectures. However, the creation of real 3D nano-objects is not trivial. Emerging non-conventional nanofabrication tools are required for this purpose. One attractive method is focused-electron-beam induced deposition (FEBID), a direct-write process of 3D nano-objects. Here, we grow 3D iron and cobalt nanopillars by FEBID using diiron nonacarbonyl Fe2(CO)9, and dicobalt octacarbonyl Co2(CO)8, respectively, as starting materials. In addition, we systematically study the composition of these nanopillars at the sub-nanometer scale by atom probe tomography, explicitly mapping the homogeneity of the radial and longitudinal composition distributions. We show a way of fabricating high-purity 3D vertical nanostructures of ˜50 nm in diameter and a few micrometers in length. Our results suggest that the purity of such 3D nanoelements (above 90 at% Fe and above 95 at% Co) is directly linked to their growth regime, in which the selected deposition conditions are crucial for the final quality of the nanostructure. Moreover, we demonstrate that FEBID and the proposed characterization technique not only allow for growth and chemical analysis of single-element structures, but also offers a new way to directly study 3D core-shell architectures. This straightforward concept could establish a promising route to the design of 3D elements for future nano-electronic devices.

  3. Realizing Large-Scale, Electronic-Grade Two-Dimensional Semiconductors.

    PubMed

    Lin, Yu-Chuan; Jariwala, Bhakti; Bersch, Brian M; Xu, Ke; Nie, Yifan; Wang, Baoming; Eichfeld, Sarah M; Zhang, Xiaotian; Choudhury, Tanushree H; Pan, Yi; Addou, Rafik; Smyth, Christopher M; Li, Jun; Zhang, Kehao; Haque, M Aman; Fölsch, Stefan; Feenstra, Randall M; Wallace, Robert M; Cho, Kyeongjae; Fullerton-Shirey, Susan K; Redwing, Joan M; Robinson, Joshua A

    2018-02-27

    Atomically thin transition metal dichalcogenides (TMDs) are of interest for next-generation electronics and optoelectronics. Here, we demonstrate device-ready synthetic tungsten diselenide (WSe 2 ) via metal-organic chemical vapor deposition and provide key insights into the phenomena that control the properties of large-area, epitaxial TMDs. When epitaxy is achieved, the sapphire surface reconstructs, leading to strong 2D/3D (i.e., TMD/substrate) interactions that impact carrier transport. Furthermore, we demonstrate that substrate step edges are a major source of carrier doping and scattering. Even with 2D/3D coupling, transistors utilizing transfer-free epitaxial WSe 2 /sapphire exhibit ambipolar behavior with excellent on/off ratios (∼10 7 ), high current density (1-10 μA·μm -1 ), and good field-effect transistor mobility (∼30 cm 2 ·V -1 ·s -1 ) at room temperature. This work establishes that realization of electronic-grade epitaxial TMDs must consider the impact of the TMD precursors, substrate, and the 2D/3D interface as leading factors in electronic performance.

  4. Three-dimensional Printing of Silver Microarchitectures Using Newtonian Nanoparticle Inks.

    PubMed

    Lee, Sanghyeon; Kim, Jung Hyun; Wajahat, Muhammad; Jeong, Hwakyung; Chang, Won Suk; Cho, Sung Ho; Kim, Ji Tae; Seol, Seung Kwon

    2017-06-07

    Although three-dimensional (3D) printing has recently emerged as a technology to potentially bring about the next industrial revolution, the limited selection of usable materials restricts its use to simple prototyping. In particular, metallic 3D printing with submicrometer spatial resolution is essential for the realization of 3D-printed electronics. Herein, a meniscus-guided 3D printing method that exploits a low-viscosity (∼7 mPa·s) silver nanoparticle (AgNP) ink meniscus with Newtonian fluid characteristics (which is compatible with conventional inkjet printers) to fabricate 3D silver microarchitectures is reported. Poly(acrylic acid)-capped AgNP ink that exhibits a continuous ink flow through a confined nozzle without aggregation is designed in this study. Guiding the ink meniscus with controlled direction and speed enables both vertical pulling and layer-by-layer processing, resulting in the creation of 3D microobjects with designed shapes other than those for simple wiring. Various highly conductive (>10 4 S·cm -1 ) 3D metallic patterns are demonstrated for applications in electronic devices. This research is expected to widen the range of materials that can be employed in 3D printing technology, with the aim of moving 3D printing beyond prototyping and into real manufacturing platforms for future electronics.

  5. 4D electron tomography.

    PubMed

    Kwon, Oh-Hoon; Zewail, Ahmed H

    2010-06-25

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  6. 4D Electron Tomography

    NASA Astrophysics Data System (ADS)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  7. Dialysis - peritoneal

    MedlinePlus

    ... and filling it with a cleansing fluid (dialysis solution). The solution contains a type of sugar that draws out ... blood vessels through the peritoneum and into the solution. After a set amount of time, the solution ...

  8. LAND APPLICATION AND SLUDGE TREATMENT

    EPA Science Inventory

    Fecal matter potentially containing pathogenic microorganisms and chemical contaminants enters community wastewater collection systems from hospitals, funeral homes, animal slaughtering operations, and dwellings. While these wastewaters are cleansed in the wastewater treatment p...

  9. Dual roles of f electrons in mixing Al 3 p character into d -orbital conduction bands for lanthanide and actinide dialuminides

    DOE PAGES

    Altman, Alison B.; Pemmaraju, C. D.; Alayoglu, Selim; ...

    2018-01-15

    Correlated electron phenomena in lanthanide and actinide materials are driven by a complex interplay between the f and d orbitals. Here in this study, aluminum K-edge x-ray absorption spectroscopy and density functional theory calculations are used to evaluate the electronic structure of the dialuminides, MAl 2 (M = Ce, Sm, Eu, Yb, Lu, U, and Pu). The results show how the energy and occupancy of the 4f or 5f orbitals impacts mixing of Al 3p character into the 5d or 6d conduction bands, which has implications for understanding the magnetic and structural properties of correlated electron systems.

  10. Effects of soap and detergents on skin surface pH, stratum corneum hydration and fat content in infants.

    PubMed

    Gfatter, R; Hackl, P; Braun, F

    1997-01-01

    In adults the influence of cleansing preparations on the pH, fat content and hydration of the skin is well documented. Studies in newborn and small infants have not been reported. Our study aimed at examining whether similar effects can be ascertained in infants. Infants without skin disease, aged 2 weeks to 16 months, entered an open, controlled and randomized study. Ten infants each had skin washed with tap water (control group), liquid detergent (pH 5.5), compact detergent (pH 5.5) or alkaline soap (pH 9.5). The pH, fat content and hydration were measured before and 10 min after cleansing. Findings were statistically evaluated by parametric covariance analysis. The skin pH increased from an average of 6.60 after cleansing in all groups. The smallest increase (+0.19) was observed in the control group, the largest (+0.45) after washing with alkaline soap. After treatment with liquid or compact detergent, the increase of the pH was only 0.09 higher than for the control group. In comparison to the compact and liquid detergents, the alkaline soap group had a significantly higher increase in pH. The fat content (mean starting value: 4.34 micrograms/cm2) decreased after washing in all groups; the smallest effect was observed in the control group (decrease of 0.93 micrograms/cm2), the highest for the alkaline soap group (decrease of 4.81 micrograms/cm2). In comparison to the compact and liquid detergents, the alkaline soap group had a higher decrease in fat content. This difference was significant for compact detergents. No statistically significant differences were observed for hydration before versus after washing. Each cleansing agent, even normal tap water, influences the skin surface. The increase of the skin pH irritates the physiological protective 'acid mantle', changes the composition of the cutaneous bacterial flora and the activity of enzymes in the upper epidermis, which have an acid pH optimum. The dissolution of fat from the skin surface may influence the hydration status leading to a dry and squamous skin.

  11. Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging.

    PubMed

    Wei, Wei; Ge, Zhi-Zheng; Lu, Hong; Gao, Yun-Jie; Hu, Yun-Biao; Xiao, Shu-Dong

    2008-01-01

    To evaluate the effects of the various methods of small bowel preparation on the quality of visualization of the small bowel and the gastrointestinal transit time of capsule endoscopy (CE). Ninety patients referred for CE were prospectively randomized to three equal groups according to the preparation used: (a) a control group, in which patients were requested to drink 1 L of clear liquids only, 12 h before the examination; (b) a purgative group, in which patients were requested to ingest 1 L of a polyethylene glycol (PEG)/electrolyte solution only, 12 h before the examination; or (c) a purgative combined with simethicone group (P-S group), in which patients were requested to ingest 1 L of PEG, 12 h before the examination, and 300 mg of simethicone, 20 min before the examination. Effects of the different bowel preparations on the gastric transit time (GTT), small bowel transit time (SBTT), examination completion rate, quality of images of the entire small intestine, and cleansing of the proximal small bowel and distal ileum were evaluated. The number of patients with "adequate" cleansing of the entire small intestine was 17 in the P-S group, 12 in the purgative group, and seven in the control group (P= 0.002). The P-S group had significantly better image quality than the control group (P= 0.001). The P-S group had significantly better image quality for the proximal small bowel (segment A [Seg A]) than the control group (P= 0.0001). Both the P-S group (P= 0.0001) and the purgative group (P= 0.0002) had significantly better image quality for the distal ileum (segment B [Seg B]) than the control group; the P-S group had significantly better image quality than the purgative group as well (P= 0.0121). Gastrointestinal transit time was not different among the three groups, nor was the examination completion rate. Purgative bowel cleansing combined with simethicone before CE improved the quality of imaging of the entire small bowel as well as the visualization of the mucosa in the proximal and distal small intestine.

  12. Impact of Newborn Skin-Cleansing With Chlorhexidine on Neonatal Mortality in Southern Nepal: A Community-Based, Cluster-Randomized Trial

    PubMed Central

    Tielsch, James M.; Darmstadt, Gary L.; Mullany, Luke C.; Khatry, Subarna K.; Katz, Joanne; LeClerq, Steven C.; Shrestha, Shardaram; Adhikari, Ramesh

    2008-01-01

    OBJECTIVE Hospital-based data from Africa suggest that newborn skin-cleansing with chlorhexidine may reduce neonatal mortality. Evaluation of this intervention in the communities where most births occur in the home has not been done. Our objective was to assess the efficacy of a 1-time skin-cleansing of newborn infants with 0.25% chlorhexidine on neonatal mortality. METHODS The design was a community-based, placebo-controlled, cluster-randomized trial in Sarlahi District in southern Nepal. Newborn infants were cleansed with infant wipes that contained 0.25% chlorhexidine or placebo solution as soon as possible after delivery in the home (median: 5.8 hours). The primary outcome was all-cause mortality by 28 days. After the completion of the randomized phase, all newborns in study clusters were converted to chlorhexidine treatment for the subsequent 9 months. RESULTS A total of 17 530 live births occurred in the enrolled sectors, 8650 and 8880 in the chlorhexidine and placebo groups, respectively. Baseline characteristics were similar in the treatment groups. Intention-to-treat analysis among all live births showed no impact of the intervention on neonatal mortality. Among live-born infants who actually received their assigned treatment (98.7%), there was a nonsignificant 11% lower neonatal mortality rate among those who were treated with chlorhexidine compared with placebo. Low birth weight infants had a statistically significant 28% reduction in neonatal mortality; there was no significant difference among infants who were born weighing ≥2500 g. After conversion to active treatment in the placebo clusters, there was a 37% reduction in mortality among low birth weight infants in the placebo clusters versus no change in the chlorhexidine clusters. CONCLUSIONS Newborn skin-wiping with chlorhexidine solution once, soon after birth, reduced neonatal mortality only among low birth weight infants. Evidence from additional trials is needed to determine whether this inexpensive and simple intervention could improve survival significantly among low birth weight infants in settings where home delivery is common and hygiene practices are poor. PMID:17210728

  13. 3D magnetic nanostructures grown by focused electron and ion beam induced deposition

    NASA Astrophysics Data System (ADS)

    Fernandez-Pacheco, Amalio

    Three-dimensional nanomagnetism is an emerging research area, where magnetic nanostructures extend along the whole space, presenting novel functionalities not limited to the substrate plane. The development of this field could have a revolutionary impact in fields such as electronics, the Internet of Things or bio-applications. In this contribution, I will show our recent work on 3D magnetic nanostructures grown by focused electron and ion beam induced deposition. This 3D nano-printing techniques, based on the local chemical vapor deposition of a gas via the interaction with electrons and ions, makes the fabrication of complex 3D magnetic nanostructures possible. First, I will show how by exploiting different growth regimes, suspended Cobalt nanowires with modulated diameter can be patterned, with potential as domain wall devices. Afterwards, I will show recent results where the synthesis of Iron-Gallium alloys can be exploited in the field of artificial multiferroics. Moreover, we are developing novel methodologies combining physical vapor deposition and 3D nano-printing, creating Permalloy 3D nanostrips with controllable widths and lengths up to a few microns. This approach has been extended to more complex geometries by exploiting advanced simulation growth techniques combining Monte Carlo and continuum model methods. Throughout the talk, I will show the methodology we are following to characterize 3D magnetic nanostructures, by combining magneto-optical Kerr effect, scanning probe microscopy and electron and X-R magnetic imaging, and I will highlight some of the challenges and opportunities when studying these structures. I acknowledge funding from EPSRC and the Winton Foundation.

  14. 3D structure of eukaryotic flagella/cilia by cryo-electron tomography.

    PubMed

    Ishikawa, Takashi

    2013-01-01

    Flagella/cilia are motile organelles with more than 400 proteins. To understand the mechanism of such complex systems, we need methods to describe molecular arrange-ments and conformations three-dimensionally in vivo. Cryo-electron tomography enabled us such a 3D structural analysis. Our group has been working on 3D structure of flagella/cilia using this method and revealed highly ordered and beautifully organized molecular arrangement. 3D structure gave us insights into the mechanism to gener-ate bending motion with well defined waveforms. In this review, I summarize our recent structural studies on fla-gella/cilia by cryo-electron tomography, mainly focusing on dynein microtubule-based ATPase motor proteins and the radial spoke, a regulatory protein complex.

  15. 3D structure of eukaryotic flagella/cilia by cryo-electron tomography

    PubMed Central

    Ishikawa, Takashi

    2013-01-01

    Flagella/cilia are motile organelles with more than 400 proteins. To understand the mechanism of such complex systems, we need methods to describe molecular arrange-ments and conformations three-dimensionally in vivo. Cryo-electron tomography enabled us such a 3D structural analysis. Our group has been working on 3D structure of flagella/cilia using this method and revealed highly ordered and beautifully organized molecular arrangement. 3D structure gave us insights into the mechanism to gener-ate bending motion with well defined waveforms. In this review, I summarize our recent structural studies on fla-gella/cilia by cryo-electron tomography, mainly focusing on dynein microtubule-based ATPase motor proteins and the radial spoke, a regulatory protein complex. PMID:27493552

  16. Electronic structure and magnetic properties of the half-metallic ferrimagnet Mn2VAl probed by soft x-ray spectroscopies

    NASA Astrophysics Data System (ADS)

    Nagai, K.; Fujiwara, H.; Aratani, H.; Fujioka, S.; Yomosa, H.; Nakatani, Y.; Kiss, T.; Sekiyama, A.; Kuroda, F.; Fujii, H.; Oguchi, T.; Tanaka, A.; Miyawaki, J.; Harada, Y.; Takeda, Y.; Saitoh, Y.; Suga, S.; Umetsu, R. Y.

    2018-01-01

    We have studied the electronic structure of ferrimagnetic Mn2VAl single crystals by means of soft x-ray absorption spectroscopy (XAS), x-ray absorption magnetic circular dichroism (XMCD), and resonant soft x-ray inelastic scattering (RIXS). We have successfully observed the XMCD signals for all the constituent elements. The Mn L2 ,3 XAS and XMCD spectra are reproduced by spectral simulations based on density-functional theory, indicating the itinerant character of the Mn 3 d states. On the other hand, the V 3 d electrons are rather localized since the ionic model can qualitatively explain the V L2 ,3 XAS and XMCD spectra. This picture is consistent with local d d excitations revealed by the V L3 RIXS.

  17. Porphyrin amino acids-amide coupling, redox and photophysical properties of bis(porphyrin) amides.

    PubMed

    Melomedov, Jascha; Wünsche von Leupoldt, Anica; Meister, Michael; Laquai, Frédéric; Heinze, Katja

    2013-07-14

    New trans-AB2C meso-substituted porphyrin amino acid esters with meso-substituents of tunable electron withdrawing power (B = mesityl, 4-C6H4F, 4-C6H4CF3, C6F5) were prepared as free amines 3a-3d, as N-acetylated derivatives Ac-3a-Ac-3d and corresponding zinc(II) complexes Zn-Ac-3a-Zn-Ac-3d. Several amide-linked bis(porphyrins) with a tunable electron density at each porphyrin site were obtained from the amino porphyrin precursors by condensation reactions (4a-4d) and mono- and bis(zinc(II)) complexes Zn(2)-4d and Zn(1)Zn(2)-4d were prepared. The electronic interaction between individual porphyrin units in bis(porphyrins) 4 is probed by electrochemical experiments (CV, EPR), electronic absorption spectroscopy, steady-state and time-resolved fluorescence spectroscopy in combination with DFT/PCM calculations on diamagnetic neutral bis(porphyrins) 4 and on respective charged mixed-valent radicals 4(+/-). The interaction via the -C6H4-NHCO-C6H4- bridge, the site of oxidation and reduction and the lowest excited singlet state S1, is tuned by the substituents on the individual porphyrins and the metalation state.

  18. Optoelectronic interconnects for 3D wafer stacks

    NASA Astrophysics Data System (ADS)

    Ludwig, David E.; Carson, John C.; Lome, Louis S.

    1996-01-01

    Wafer and chip stacking are envisioned as a means of providing increased processing power within the small confines of a three-dimensional structure. Optoelectronic devices can play an important role in these dense 3-D processing electronic packages in two ways. In pure electronic processing, optoelectronics can provide a method for increasing the number of input/output communication channels within the layers of the 3-D chip stack. Non-free space communication links allow the density of highly parallel input/output ports to increase dramatically over typical edge bus connections. In hybrid processors, where electronics and optics play a role in defining the computational algorithm, free space communication links are typically utilized for, among other reasons, the increased network link complexity which can be achieved. Free space optical interconnections provide bandwidths and interconnection complexity unobtainable in pure electrical interconnections. Stacked 3-D architectures can provide the electronics real estate and structure to deal with the increased bandwidth and global information provided by free space optical communications. This paper provides definitions and examples of 3-D stacked architectures in optoelectronics processors. The benefits and issues of these technologies are discussed.

  19. Optoelectronic interconnects for 3D wafer stacks

    NASA Astrophysics Data System (ADS)

    Ludwig, David; Carson, John C.; Lome, Louis S.

    1996-01-01

    Wafer and chip stacking are envisioned as means of providing increased processing power within the small confines of a three-dimensional structure. Optoelectronic devices can play an important role in these dense 3-D processing electronic packages in two ways. In pure electronic processing, optoelectronics can provide a method for increasing the number of input/output communication channels within the layers of the 3-D chip stack. Non-free space communication links allow the density of highly parallel input/output ports to increase dramatically over typical edge bus connections. In hybrid processors, where electronics and optics play a role in defining the computational algorithm, free space communication links are typically utilized for, among other reasons, the increased network link complexity which can be achieved. Free space optical interconnections provide bandwidths and interconnection complexity unobtainable in pure electrical interconnections. Stacked 3-D architectures can provide the electronics real estate and structure to deal with the increased bandwidth and global information provided by free space optical communications. This paper will provide definitions and examples of 3-D stacked architectures in optoelectronics processors. The benefits and issues of these technologies will be discussed.

  20. The energy spectrum of Jovian electrons in interplanetary space

    NASA Technical Reports Server (NTRS)

    Christon, S. P.; Cummings, A. C.; Stone, E. C.; Webber, W. R.

    1985-01-01

    The energy spectrum of electrons with energies approximately 10 to approximately 180 MeV measured with the electron telescope on the Voyager 1 and 2 spacecraft in interplanetary space from 1978 to 1983 is reported. The kinetic energy of electrons is determined by double dE/dx measurements from the first two detectors (D1,D2) of a stack of eight solid state detectors and by the range of particle penetration into the remaining six detectors (D3 to D8) which are interleaved with tungsten absorbers.

  1. Observation of Internal Photoinduced Electron and Hole Separation in Hybrid Two-Dimentional Perovskite Films.

    PubMed

    Liu, Junxue; Leng, Jing; Wu, Kaifeng; Zhang, Jun; Jin, Shengye

    2017-02-01

    Two-dimensional (2D) organolead halide perovskites are promising for various optoelectronic applications. Here we report a unique spontaneous charge (electron/hole) separation property in multilayered (BA) 2 (MA) n-1 Pb n I 3n+1 (BA = CH 3 (CH 2 ) 3 NH 3 + , MA = CH 3 NH 3 + ) 2D perovskite films by studying the charge carrier dynamics using ultrafast transient absorption and photoluminescence spectroscopy. Surprisingly, the 2D perovskite films, although nominally prepared as "n = 4", are found to be mixture of multiple perovskite phases, with n = 2, 3, 4 and ≈ ∞, that naturally align in the order of n along the direction perpendicular to the substrate. Driven by the band alignment between 2D perovskites phases, we observe consecutive photoinduced electron transfer from small-n to large-n phases and hole transfer in the opposite direction on hundreds of picoseconds inside the 2D film of ∼358 nm thickness. This internal charge transfer efficiently separates electrons and holes to the upper and bottom surfaces of the films, which is a unique property beneficial for applications in photovoltaics and other optoelectronics devices.

  2. A simple, low-cost conductive composite material for 3D printing of electronic sensors.

    PubMed

    Leigh, Simon J; Bradley, Robert J; Purssell, Christopher P; Billson, Duncan R; Hutchins, David A

    2012-01-01

    3D printing technology can produce complex objects directly from computer aided digital designs. The technology has traditionally been used by large companies to produce fit and form concept prototypes ('rapid prototyping') before production. In recent years however there has been a move to adopt the technology as full-scale manufacturing solution. The advent of low-cost, desktop 3D printers such as the RepRap and Fab@Home has meant a wider user base are now able to have access to desktop manufacturing platforms enabling them to produce highly customised products for personal use and sale. This uptake in usage has been coupled with a demand for printing technology and materials able to print functional elements such as electronic sensors. Here we present formulation of a simple conductive thermoplastic composite we term 'carbomorph' and demonstrate how it can be used in an unmodified low-cost 3D printer to print electronic sensors able to sense mechanical flexing and capacitance changes. We show how this capability can be used to produce custom sensing devices and user interface devices along with printed objects with embedded sensing capability. This advance in low-cost 3D printing with offer a new paradigm in the 3D printing field with printed sensors and electronics embedded inside 3D printed objects in a single build process without requiring complex or expensive materials incorporating additives such as carbon nanotubes.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nasirabadi, P. Shojaee; Jabbari, M.; Hattel, J. H.

    Electronic systems are sometimes exposed to harsh environmental conditions of temperature and humidity. Moisture transfer into electronic enclosures and condensation can cause several problems such as corrosion and alteration in thermal stresses. It is therefore essential to study the local climate inside the enclosures to be able to protect the electronic systems. In this work, moisture transfer into a typical electronic enclosure is numerically studied using CFD. In order to reduce the CPU-time and make a way for subsequent factorial design analysis, a simplifying modification is applied in which the real 3D geometry is approximated by a 2D axial symmetrymore » one. The results for 2D and 3D models were compared in order to calibrate the 2D representation. Furthermore, simulation results were compared with experimental data and good agreement was found.« less

  4. Three-dimensional electron microscopy simulation with the CASINO Monte Carlo software.

    PubMed

    Demers, Hendrix; Poirier-Demers, Nicolas; Couture, Alexandre Réal; Joly, Dany; Guilmain, Marc; de Jonge, Niels; Drouin, Dominique

    2011-01-01

    Monte Carlo softwares are widely used to understand the capabilities of electron microscopes. To study more realistic applications with complex samples, 3D Monte Carlo softwares are needed. In this article, the development of the 3D version of CASINO is presented. The software feature a graphical user interface, an efficient (in relation to simulation time and memory use) 3D simulation model, accurate physic models for electron microscopy applications, and it is available freely to the scientific community at this website: www.gel.usherbrooke.ca/casino/index.html. It can be used to model backscattered, secondary, and transmitted electron signals as well as absorbed energy. The software features like scan points and shot noise allow the simulation and study of realistic experimental conditions. This software has an improved energy range for scanning electron microscopy and scanning transmission electron microscopy applications. Copyright © 2011 Wiley Periodicals, Inc.

  5. Three-Dimensional Electron Microscopy Simulation with the CASINO Monte Carlo Software

    PubMed Central

    Demers, Hendrix; Poirier-Demers, Nicolas; Couture, Alexandre Réal; Joly, Dany; Guilmain, Marc; de Jonge, Niels; Drouin, Dominique

    2011-01-01

    Monte Carlo softwares are widely used to understand the capabilities of electron microscopes. To study more realistic applications with complex samples, 3D Monte Carlo softwares are needed. In this paper, the development of the 3D version of CASINO is presented. The software feature a graphical user interface, an efficient (in relation to simulation time and memory use) 3D simulation model, accurate physic models for electron microscopy applications, and it is available freely to the scientific community at this website: www.gel.usherbrooke.ca/casino/index.html. It can be used to model backscattered, secondary, and transmitted electron signals as well as absorbed energy. The software features like scan points and shot noise allow the simulation and study of realistic experimental conditions. This software has an improved energy range for scanning electron microscopy and scanning transmission electron microscopy applications. PMID:21769885

  6. The Electronic Structure of Mn in Oxides, Coordination Complexes, and the Oxygen-Evolving Complex of Photosystem II Studied by Resonant Inelastic X-ray Scattering

    PubMed Central

    Yano, Junko; Visser, Hendrik; Robblee, John H.; Gu, Weiwei; de Groot, Frank M. F.; Christou, George; Pecoraro, Vincent L.

    2014-01-01

    Resonant inelastic X-ray scattering (RIXS) was used to collect Mn K pre-edge spectra and to study the electronic structure in oxides, molecular coordination complexes, as well as the S1 and S2 states of the oxygen-evolving complex (OEC) of photosystem II (PS II). The RIXS data yield two-dimensional plots that can be interpreted along the incident (absorption) energy or the energy transfer axis. The second energy dimension separates the pre-edge (predominantly 1s to 3d transitions) from the main K-edge, and a detailed analysis is thus possible. The 1s2p RIXS final-state electron configuration along the energy transfer axis is identical to conventional L-edge absorption spectroscopy, and the RIXS spectra are therefore sensitive to the Mn spin state. This new technique thus yields information on the electronic structure that is not accessible in conventional K-edge absorption spectroscopy. The line splittings can be understood within a ligand field multiplet model, i.e., (3d,3d) and (2p,3d) two-electron interactions are crucial to describe the spectral shapes in all systems. We propose to explain the shift of the K pre-edge absorption energy upon Mn oxidation in terms of the effective number of 3d electrons (fractional 3d orbital population). The spectral changes in the Mn 1s2p3/2 RIXS spectra between the PS II S1 and S2 states are small compared to that of the oxides and two of the coordination complexes (MnIII(acac)3 and MnIV(sal)2(bipy)). We conclude that the electron in the step from S1 to S2 is transferred from a strongly delocalized orbital. PMID:15303869

  7. Three-dimensional locations of gold-labeled proteins in a whole mount eukaryotic cell obtained with 3nm precision using aberration-corrected scanning transmission electron microscopy.

    PubMed

    Dukes, Madeline J; Ramachandra, Ranjan; Baudoin, Jean-Pierre; Gray Jerome, W; de Jonge, Niels

    2011-06-01

    Three-dimensional (3D) maps of proteins within the context of whole cells are important for investigating cellular function. However, 3D reconstructions of whole cells are challenging to obtain using conventional transmission electron microscopy (TEM). We describe a methodology to determine the 3D locations of proteins labeled with gold nanoparticles on whole eukaryotic cells. The epidermal growth factor receptors on COS7 cells were labeled with gold nanoparticles, and critical-point dried whole-mount cell samples were prepared. 3D focal series were obtained with aberration-corrected scanning transmission electron microscopy (STEM), without tilting the specimen. The axial resolution was improved with deconvolution. The vertical locations of the nanoparticles in a whole-mount cell were determined with a precision of 3nm. From the analysis of the variation of the axial positions of the labels we concluded that the cellular surface was ruffled. To achieve sufficient stability of the sample under electron beam irradiation during the recording of the focal series, the sample was carbon coated. A quantitative method was developed to analyze the stability of the ultrastructure after electron beam irradiation using TEM. The results of this study demonstrate the feasibility of using aberration-corrected STEM to study the 3D nanoparticle distribution in whole cells. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Three-dimensional locations of gold-labeled proteins in a whole mount eukaryotic cell obtained with 3 nm precision using aberration-corrected scanning transmission electron microscopy

    PubMed Central

    Dukes, Madeline J.; Ramachandra, Ranjan; Baudoin, Jean-Pierre; Jerome, W. Gray; de Jonge, Niels

    2011-01-01

    Three-dimensional (3D) maps of proteins within the context of whole cells are important for investigating cellular function. However, 3D reconstructions of whole cells are challenging to obtain using conventional transmission electron microscopy (TEM). We describe a methodology to determine the 3D locations of proteins labeled with gold nanoparticles on whole eukaryotic cells. The epidermal growth factor receptors on COS7 cells were labeled with gold nanoparticles, and critical-point dried whole-mount cell samples were prepared. 3D focal series were obtained with aberration-corrected scanning transmission electron microscopy (STEM), without tilting the specimen. The axial resolution was improved with deconvolution. The vertical locations of the nanoparticles in a whole-mount cell were determined with a precision of 3 nm. From the analysis of the variation of the axial positions of the labels we concluded that the cellular surface was ruffled. To achieve sufficient stability of the sample under the electron beam irradiation during the recording of the focal series, the sample was carbon coated. A quantitative method was developed to analyze the stability of the ultrastructure after electron beam irradiation using TEM. The results of this study demonstrate the feasibility of using aberration-corrected STEM to study the 3D nanoparticle distribution in whole cells. PMID:21440635

  9. Electronic and magnetic properties of Fe-, Co-, and Ni-decorated BC3: A first-principles study

    NASA Astrophysics Data System (ADS)

    Zhu, Jingzhong; Zhao, Yinchang; Zulfiqar, Muhammad; Zeng, Shuming; Ni, Jun

    2018-05-01

    The electronic and magnetic properties of Fe-, Co-, and Ni-decorated two dimensional (2D) BC3 are systematically investigated by first-principles calculations. We find that the Fe, Co, and Ni atoms can be strongly adsorbed on the hollow sites of 2D BC3. Fe and Co adatoms are more stable when adsorbed on the hollow sites of the carbon rings in the 2D BC3, while the hollow sites of boron-carbon rings in the 2D BC3 are the most stable sites for the adsorption of Ni adatoms. These proposed metal-BC3 complexes exhibit interesting electronic and magnetic behaviors. In particular, the Fe-BC3 and Co-BC3 complexes are metals with magnetic ground states , while the Ni-BC3 complex behaves as a nonmagnetic semiconductor with a direct bandgap. Furthermore, our magnetic analysis reveals that induced magnetism in the Fe-BC3 and Co-BC3 complexes arises from their local magnetic moments. Functionalization of 2D BC3 through these metal-adatom adsorption appears to be a promising way to extend its applications.

  10. On the similarity of the bonding in NiS and NiO

    NASA Technical Reports Server (NTRS)

    Bauschlicher, C. W., Jr.

    1985-01-01

    The bonding in NiS is found to be quite similar to that in NiO, having an ionic contribution arising from the donation of the Ni 4s electron to the S atom and a covalent component arising from bonds between the Ni 3d and the S 3p. The one-electron d bonds are found to be of equal strength for NiO and NiS, but the two-electron d bonds are weaker for NiS.

  11. Low Temperature Specific Heat in Lightly Mn-Substituted Electron-Doped SrTiO3

    NASA Astrophysics Data System (ADS)

    Okuda, Tetsuji; Hata, Hiroto; Eto, Takahiro; Sobaru, Shogo; Oda, Ryosuke; Noda, Masaaki; Kuwahara, Hideki

    2017-08-01

    We found large changes in the low-temperature specific heat (low-T C) in the lightly Mn-substituted electron-doped perovskites Sr0.95La0.05Ti1-yMnzO3 with y = 0.02 and 0.04 by applying magnetic fields up to 9 T. The changes in the low-T C are qualitatively well explained by the Schottky specific heat (CSch) of localized spins of the Mn 3d electrons in weak internal magnetic fields via itinerant electrons. However, the actual numbers of localized spins estimated from CSch are about 30% smaller than the expected values. Part of the localized spins of the Mn 3d electrons may disappear due to Kondo coupling with the itinerant electrons.

  12. 3D imaging by serial block face scanning electron microscopy for materials science using ultramicrotomy.

    PubMed

    Hashimoto, Teruo; Thompson, George E; Zhou, Xiaorong; Withers, Philip J

    2016-04-01

    Mechanical serial block face scanning electron microscopy (SBFSEM) has emerged as a means of obtaining three dimensional (3D) electron images over volumes much larger than possible by focused ion beam (FIB) serial sectioning and at higher spatial resolution than achievable with conventional X-ray computed tomography (CT). Such high resolution 3D electron images can be employed for precisely determining the shape, volume fraction, distribution and connectivity of important microstructural features. While soft (fixed or frozen) biological samples are particularly well suited for nanoscale sectioning using an ultramicrotome, the technique can also produce excellent 3D images at electron microscope resolution in a time and resource-efficient manner for engineering materials. Currently, a lack of appreciation of the capabilities of ultramicrotomy and the operational challenges associated with minimising artefacts for different materials is limiting its wider application to engineering materials. Consequently, this paper outlines the current state of the art for SBFSEM examining in detail how damage is introduced during slicing and highlighting strategies for minimising such damage. A particular focus of the study is the acquisition of 3D images for a variety of metallic and coated systems. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  13. 3D Microstructural Architectures for Metal and Alloy Components Fabricated by 3D Printing/Additive Manufacturing Technologies

    NASA Astrophysics Data System (ADS)

    Martinez, E.; Murr, L. E.; Amato, K. N.; Hernandez, J.; Shindo, P. W.; Gaytan, S. M.; Ramirez, D. A.; Medina, F.; Wicker, R. B.

    The layer-by-layer building of monolithic, 3D metal components from selectively melted powder layers using laser or electron beams is a novel form of 3D printing or additive manufacturing. Microstructures created in these 3D products can involve novel, directional solidification structures which can include crystallographically oriented grains containing columnar arrays of precipitates characteristic of a microstructural architecture. These microstructural architectures are advantageously rendered in 3D image constructions involving light optical microscopy and scanning and transmission electron microscopy observations. Microstructural evolution can also be effectively examined through 3D image sequences which, along with x-ray diffraction (XRD) analysis in the x-y and x-z planes, can effectively characterize related crystallographic/texture variances. This paper compares 3D microstructural architectures in Co-base and Ni-base superalloys, columnar martensitic grain structures in 17-4 PH alloy, and columnar copper oxides and dislocation arrays in copper.

  14. Optimal Bowel Preparation for Video Capsule Endoscopy

    PubMed Central

    Song, Hyun Joo; Moon, Jeong Seop; Shim, Ki-Nam

    2016-01-01

    During video capsule endoscopy (VCE), several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies, consensus, and guidelines regarding different kinds of bowel cleansing agents in bowel preparation for small bowel VCE. Presently, polyethylene glycol- (PEG-) based regimens are given primary recommendation. Sodium picosulphate-based regimens are secondarily recommended, as their cleansing efficacy is less than that of PEG-based regimens. Sodium phosphate as well as complementary simethicone and prokinetics use are considered. In this paper, we reviewed previous studies regarding bowel preparation for small bowel VCE and suggested optimal bowel preparation of VCE. PMID:26880894

  15. Efficacy of preparation solutions and cleansing techniques on contamination of the skin in foot and ankle surgery: A systematic review and meta-analysis.

    PubMed

    Yammine, K; Harvey, A

    2013-04-01

    We report a systematic review and meta-analysis of published randomised and quasi-randomised trials evaluating the efficacy of pre-operative skin antisepsis and cleansing techniques in reducing foot and ankle skin flora. The post-preparation culture number (Post-PCN) was the primary outcome. The data were evaluated using a modified version of the Cochrane Collaboration’s tool. We identified eight trials (560 participants, 716 feet) that met the inclusion criteria. There was a significant difference in the proportions of Post-PCN between hallux nailfold (HNF) and toe web spaces (TWS) sites: 0.47 vs 0.22, respectively (95% confidence interval (CI) 0.182937 to 0.304097; p < 0.0001). Meta-analyses showed that alcoholic chlorhexidine had better efficacy than alcoholic povidone-iodine (PI) at HNF sites (risk difference 0.19 (95% CI 0.08 to 0.30); p = 0.0005); a two-step intervention using PI scrub and paint (S&P) followed by alcohol showed significantly better efficacy over PI (S&P) alone at TWS sites (risk difference 0.13 (95% CI 0.02 to 0.24); p = 0.0169); and a two-step intervention using chlorhexidine scrub followed by alcohol showed significantly better efficacy over PI (S&P) alone at the combined (HNF with TWS) sites (risk difference 0.27 (95% CI 0.13 to 0.40); p < 0.0001). No significant difference was found between cleansing techniques.

  16. A 6% Benzoyl Peroxide Foaming Cloth Cleanser Used in the Treatment of Acne Vulgaris

    PubMed Central

    2009-01-01

    Objective: The study was conducted to evaluate the product attributes of a new benzoyl peroxide-containing foaming cloth cleanser and to compare the overall patient satisfaction of this product with two currently available benzoyl peroxide acne products (6% benzoyl peroxide cleanser and 4% benzoyl peroxide wash). Design: This was a randomized, single-blind study. Setting: Two clinical trial sites. Participants: Male and female subjects (N=193) aged 17 to 30 years with a history of acne vulgaris were enrolled. Measures: Subjects initially cleansed their face with the benzoyl peroxide foaming cloth and then completed a product-attribute survey. Following an interval of five minutes or more, subjects cleansed their face again using one of two randomly assigned comparator benzoyl peroxide-containing cleansing products and then completed a comparative survey. Survey results were tabulated and a top-two box analysis was performed. Results: Following the use of the benzoyl peroxide-containing foaming cloth, 94 percent of the product-attribute responses were positive (p≤0.05). With respect to convenience, usability, and cosmetic elegance, the majority of subjects indicated a preference for the benzoyl peroxide foaming cloth compared to the 6% benzoyl peroxide cleanser and 4% benzoyl peroxide wash (for each, p≤0.05). There were no reports of adverse events. Conclusion: These attributes supporting preference for the benzoyl peroxide foaming cloth cleanser may improve patient satisfaction with topical acne treatment resulting in improved patient compliance. (J Clin Aesthetic Dermatol. 2009;2(7):26–29.) PMID:20729967

  17. Magnetic resonance colonography without bowel cleansing: a prospective cross sectional study in a screening population

    PubMed Central

    Kuehle, Christiane A; Langhorst, Jost; Ladd, Susanne C; Zoepf, Thomas; Nuefer, Michael; Grabellus, Florian; Barkhausen, Joerg; Gerken, Guido; Lauenstein, Thomas C

    2007-01-01

    Background and aim To evaluate the diagnostic accuracy of magnetic resonance colonography (MRC) without bowel cleansing in a screening population and compare the results to colonoscopy as a standard of reference. Methods 315 screening patients, older than 50 years with a normal risk profile for colorectal cancer, were included in this study. For MRC, a tagging agent (5.0% Gastrografin, 1.0% barium sulphate, 0.2% locust bean gum) was ingested with each main meal within 2 days prior to MRC. No bowel cleansing was applied. For the magnetic resonance examination, a rectal water enema was administered. Data collection was based on contrast enhanced T1 weighted images and TrueFISP images. Magnetic resonance data were analysed for image quality and the presence of colorectal lesions. Conventional colonoscopy and histopathological samples served as reference. Results In 4% of all colonic segments, magnetic resonance image quality was insufficient because of untagged faecal material. Adenomatous polyps >5 mm were detected by means of MRC, with a sensitivity of 83.0%. Overall specificity was 90.2% (false positive findings in 19 patients). However, only 16 of 153 lesions <5 mm and 9 of 127 hyperplastic polyps could be visualised on magnetic resonance images. Conclusions Faecal tagging MRC is applicable for screening purposes. It provides good accuracy for the detection of relevant (ie, adenomatous) colorectal lesions >5 mm in a screening population. However, refinements to optimise image quality of faecal tagging are needed. PMID:17341542

  18. Hand hygiene using a new hand-cleansing formulation without sanitizers: Effect on Staphylococcus aureus removal and recovery of properties against skin damage.

    PubMed

    Asaoka, Kentaro; Endo, Shiro; Suzuki, Yuki; Komuro, Satoru; Nemoto, Tadanobu; Kaku, Mitsuo

    2016-08-01

    Staphylococcus aureus is known to form a biofilm and colonize on damaged skin of the hands. We investigated changes in the quantity of S aureus on the hands and changes in skin damage when using a hand-cleansing formulation with potassium oleate but without a sanitizer (formulation A), which is highly effective in removing S aureus biofilm and causes minimal skin damage. The participants (14 medical staff members) used 2 types of hand-cleansing formulations (formulations A and B), each for 4 weeks. S aureus of the hands was cultured from swab samples on agar plates. Surface of hands was measured using an ultraviolet light microscope. The quantity of S aureus after using formulation A for 4 weeks was 10(1.08 ± 0.05) CFU/mL, a statistically significant decrease from the quantity of S aureus (10(1.59 ± 0.19) CFU/mL) just before use (P = .029). Also, dryness of hand surfaces decreased. With formulation B, the quantity of S aureus did not significantly change from before to after use (P > .05). This presumably occurs because formulation A gently removes S aureus biofilm. Formulation A removed S aureus from the hands of participants, and skin damage on the hands improved. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Controlling entangled spin-orbit coupling of 5 d states with interfacial heterostructure engineering

    DOE PAGES

    Kim, J. -W.; Choi, Y.; Chun, S. H.; ...

    2018-03-26

    Here, the combination of strong electron correlations in 3d transition metal oxides and spin-orbit interactions in the 5d counterpart can give rise to exotic electronic and magnetic properties. Here, the nature of emerging phenomena at the interface between SrIrO 3 (SIO) and La 2/3Sr 1/3MnO 3 (LSMO) is presented. Nominally, SIO with strong spin-orbit interaction is metallic and nonmagnetic on the verge of a metal-insulator transition, whereas LSMO is metallic and ferromagnetic with itinerant character and high spin polarization. In the 1:1 LSMO/SIO superlattice, we observe ferromagnetic Mn moments with an insulating behavior, accompanied by antiferromagnetic ordering in SIO. Element-resolvedmore » x-ray magnetic circular dichroism proves that there is a weak net ferromagnetic Ir moment aligned antiparallel to the Mn counterpart. The branching ratio shows the formation of molecular-orbitals between the Mn and Ir layers modifying the Ir 5d electronic configuration through the mixture of t 2g and e g states, resulting in a deviation from J eff = ½. This result demonstrates a pathway to manipulate the spin-orbit entanglement in 5d states with 2-dimensional 3d spin-polarized electrons through heterostructure design.« less

  20. Controlling entangled spin-orbit coupling of 5 d states with interfacial heterostructure engineering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J. -W.; Choi, Y.; Chun, S. H.

    Here, the combination of strong electron correlations in 3d transition metal oxides and spin-orbit interactions in the 5d counterpart can give rise to exotic electronic and magnetic properties. Here, the nature of emerging phenomena at the interface between SrIrO 3 (SIO) and La 2/3Sr 1/3MnO 3 (LSMO) is presented. Nominally, SIO with strong spin-orbit interaction is metallic and nonmagnetic on the verge of a metal-insulator transition, whereas LSMO is metallic and ferromagnetic with itinerant character and high spin polarization. In the 1:1 LSMO/SIO superlattice, we observe ferromagnetic Mn moments with an insulating behavior, accompanied by antiferromagnetic ordering in SIO. Element-resolvedmore » x-ray magnetic circular dichroism proves that there is a weak net ferromagnetic Ir moment aligned antiparallel to the Mn counterpart. The branching ratio shows the formation of molecular-orbitals between the Mn and Ir layers modifying the Ir 5d electronic configuration through the mixture of t 2g and e g states, resulting in a deviation from J eff = ½. This result demonstrates a pathway to manipulate the spin-orbit entanglement in 5d states with 2-dimensional 3d spin-polarized electrons through heterostructure design.« less

  1. Controlling entangled spin-orbit coupling of 5 d states with interfacial heterostructure engineering

    NASA Astrophysics Data System (ADS)

    Kim, J.-W.; Choi, Y.; Chun, S. H.; Haskel, D.; Yi, D.; Ramesh, R.; Liu, J.; Ryan, P. J.

    2018-03-01

    The combination of strong electron correlations in 3 d transition-metal oxides and spin-orbit interactions in the 5 d counterpart can give rise to exotic electronic and magnetic properties. Here, the nature of emerging phenomena at the interface between SrIr O3 (SIO) and L a2 /3S r1 /3Mn O3 (LSMO) is presented. Nominally, SIO with strong spin-orbit interaction is metallic and nonmagnetic on the verge of a metal-insulator transition, whereas LSMO is metallic and ferromagnetic with itinerant character and high spin polarization. In the 1:1 LSMO/SIO superlattice, we observe ferromagnetic Mn moments with an insulating behavior, accompanied by antiferromagnetic ordering in SIO. Element-resolved x-ray magnetic circular dichroism proves that there is a weak net ferromagnetic Ir moment aligned antiparallel to the Mn counterpart. The branching ratio shows the formation of molecular orbitals between the Mn and Ir layers modifying the Ir 5 d electronic configuration through the mixture of t2 g and eg states, resulting in a deviation from Jeff=1 /2 . This result demonstrates a pathway to manipulate the spin-orbit entanglement in 5 d states with two-dimensional 3 d spin-polarized electrons through heterostructure design.

  2. Electron interaction with phosphate cytidine oligomer dCpdC: base-centered radical anions and their electronic spectra.

    PubMed

    Gu, Jiande; Wang, Jing; Leszczynski, Jerzy

    2014-01-30

    Computational chemistry approach was applied to explore the nature of electron attachment to cytosine-rich DNA single strands. An oligomer dinucleoside phosphate deoxycytidylyl-3',5'-deoxycytidine (dCpdC) was selected as a model system for investigations by density functional theory. Electron distribution patterns for the radical anions of dCpdC in aqueous solution were explored. The excess electron may reside on the nucleobase at the 5' position (dC(•-)pdC) or at the 3' position (dCpdC(•-)). From comparison with electron attachment to the cytosine related DNA fragments, the electron affinity for the formation of the cytosine-centered radical anion in DNA is estimated to be around 2.2 eV. Electron attachment to cytosine sites in DNA single strands might cause perturbations of local structural characteristics. Visible absorption spectroscopy may be applied to validate computational results and determine experimentally the existence of the base-centered radical anion. The time-dependent DFT study shows the absorption around 550-600 nm for the cytosine-centered radical anions of DNA oligomers. This indicates that if such species are detected experimentally they would be characterized by a distinctive color.

  3. Effect on skin hydration of using baby wipes to clean the napkin area of newborn babies: assessor-blinded randomised controlled equivalence trial.

    PubMed

    Lavender, Tina; Furber, Christine; Campbell, Malcolm; Victor, Suresh; Roberts, Ian; Bedwell, Carol; Cork, Michael J

    2012-06-01

    Some national guidelines recommend the use of water alone for napkin cleansing. Yet, there is a readiness, amongst many parents, to use baby wipes. Evidence from randomised controlled trials, of the effect of baby wipes on newborn skin integrity is lacking. We conducted a study to examine the hypothesis that the use of a specifically formulated cleansing wipe on the napkin area of newborn infants (<1 month) has an equivalent effect on skin hydration when compared with using cotton wool and water (usual care). A prospective, assessor-blinded, randomised controlled equivalence trial was conducted during 2010. Healthy, term babies (n=280), recruited within 48 hours of birth, were randomly assigned to have their napkin area cleansed with an alcohol-free baby wipe (140 babies) or cotton wool and water (140 babies). Primary outcome was change in hydration from within 48 hours of birth to 4 weeks post-birth. Secondary outcomes comprised changes in trans-epidermal water loss, skin surface pH and erythema, presence of microbial skin contaminants/irritants at 4 weeks and napkin dermatitis reported by midwife at 4 weeks and mother during the 4 weeks. Complete hydration data were obtained for 254 (90.7 %) babies. Wipes were shown to be equivalent to water and cotton wool in terms of skin hydration (intention-to-treat analysis: wipes 65.4 (SD 12.4) vs. water 63.5 (14.2), p=0.47, 95% CI -2.5 to 4.2; per protocol analysis: wipes 64.6 (12.4) vs. water 63.6 (14.3), p=0.53, 95% CI -2.4 to 4.2). No significant differences were found in the secondary outcomes, except for maternal-reported napkin dermatitis, which was higher in the water group (p=0.025 for complete responses). Baby wipes had an equivalent effect on skin hydration when compared with cotton wool and water. We found no evidence of any adverse effects of using these wipes. These findings offer reassurance to parents who choose to use baby wipes and to health professionals who support their use. Current Controlled Trials ISRCTN86207019.

  4. Katharsis of the skin: Peeling applications and agents of chemical peelings in Greek medical textbooks of Graeco-Roman antiquity.

    PubMed

    Ursin, F; Steger, F; Borelli, C

    2018-04-28

    Recipes for peelings date back to medical texts of old Egypt. The oldest medical papyri contain recipes for "improving beauty of the skin" and "removing wrinkles" by use of agents like salt and soda. The Egyptian Queen Cleopatra (69-30 BC) is said to have taken bathes in donkey's milk in order to improve the beauty of her skin. However, little is known about other agents and peeling applications in later Greek medical textbooks. We will discover new agents and describe ancient peeling applications. First, we will have to identify ancient Greek medical terms for the modern terms "peeling" and "chemical peeling". Second, based on the identified terms we will perform a systematic fulltext search for agents in original sources. Third, we will categorize the results into three peeling applications: (1) cleansing, (2) aesthetical improvement of the skin, and (3) therapy of dermatological diseases. We performed a full systematic keyword search with the identified Greek terms in databases of ancient Greek texts. Our keywords for peeling and chemical peeling are "smēxis" and "trīpsis". Our keywords for agents of peeling and chemical peeling are "smégmata", "rhýmmata", "kathartiká", and "trímmata". Diocles (4 th century BC) was the first one who mentioned "smēxis" and "trīpsis" as parts of daily cleansing routine. Criton (2 nd century AD) wrote about peeling applications, but any reference to the agents is lost. Antyllos (2 nd century AD) composed three lists of peeling applications including agents. Greek medical textbooks of Graeco-Roman antiquity report several peeling applications like cleansing, brightening, darkening, softening, and aesthetical improvement of the skin by use of peeling and chemical peeling, as well as therapy of dermatological diseases. There are 27 ancient agents for what is contemporarily called peeling and chemical peeling. We discovered more specific agents than hitherto known to research. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Electron acceleration in the Solar corona - 3D PiC code simulations of guide field reconnection

    NASA Astrophysics Data System (ADS)

    Alejandro Munoz Sepulveda, Patricio

    2017-04-01

    The efficient electron acceleration in the solar corona detected by means of hard X-ray emission is still not well understood. Magnetic reconnection through current sheets is one of the proposed production mechanisms of non-thermal electrons in solar flares. Previous works in this direction were based mostly on test particle calculations or 2D fully-kinetic PiC simulations. We have now studied the consequences of self-generated current-aligned instabilities on the electron acceleration mechanisms by 3D magnetic reconnection. For this sake, we carried out 3D Particle-in-Cell (PiC) code numerical simulations of force free reconnecting current sheets, appropriate for the description of the solar coronal plasmas. We find an efficient electron energization, evidenced by the formation of a non-thermal power-law tail with a hard spectral index smaller than -2 in the electron energy distribution function. We discuss and compare the influence of the parallel electric field versus the curvature and gradient drifts in the guiding-center approximation on the overall acceleration, and their dependence on different plasma parameters.

  6. Time Dependent Predictive Modeling of DIII-D ITER Baseline Scenario using Predictive TRANSP

    NASA Astrophysics Data System (ADS)

    Grierson, B. A.; Andre, R. G.; Budny, R. V.; Solomon, W. M.; Yuan, X.; Candy, J.; Pinsker, R. I.; Staebler, G. M.; Holland, C.; Rafiq, T.

    2015-11-01

    ITER baseline scenario discharges on DIII-D are modeled with TGLF and MMM transitioning from combined ECH (3.3MW) +NBI(2.8MW) heating to NBI only (3.0 MW) heating maintaining βN = 2.0 on DIII-D predicting temperature, density and rotation for comparison to experimental measurements. These models capture the reduction of confinement associated with direct electron heating H98y2 = 0.89 vs. 1.0) consistent with stiff electron transport. Reasonable agreement between experimental and modeled temperature profiles is achieved for both heating methods, whereas density and momentum predictions differ significantly. Transport fluxes from TGLF indicate that on DIII-D the electron energy flux has reached a transition from low-k to high-k turbulence with more stiff high-k transport that inhibits an increase in core electron stored energy with additional electron heating. Projections to ITER also indicate high electron stiffness. Supported by US DOE DE-AC02-09CH11466, DE-FC02-04ER54698, DE-FG02-07ER54917, DE-FG02-92-ER54141.

  7. Antiferromagnetic d-Electron Exchange via a Spin-Singlet π-Electron Ground State in an Organic Conductor

    NASA Astrophysics Data System (ADS)

    Tokumoto, T.; Brooks, J. S.; Oshima, Y.; Choi, E. S.; Brunel, L. C.; Akutsu, H.; Kaihatsu, T.; Yamada, J.; van Tol, J.

    2008-04-01

    Electron spin resonance reveals the spin behavior of conduction (π) and localized (d) electrons in β-(BDA-TTP)2MCl4 (M=Fe, Ga). Both the Ga3+(S=0) and Fe3+(S=5/2) compounds exhibit a metal-insulator transition at 113 K with the simultaneous formation of a spin-singlet ground state in the π electron system of the donor molecules. The behavior is consistent with charge ordering in β-(BDA-TTP)2MCl4 at the metal-insulator transition. At 5 K, the Fe3+ compound orders antiferromagnetically, even though the π electrons, which normally would facilitate magnetic exchange, are localized nonmagnetic singlets.

  8. Orbital configuration in CaTiO 3 films on NdGaO 3

    DOE PAGES

    Cao, Yanwei; Park, Se Young; Liu, Xiaoran; ...

    2016-10-13

    Despite its use as a constituent layer for realization of a polar metal and interfacial conductivity, the microscopic study of electronic structure of CaTiO 3 is still very limited. Here, we epitaxially stabilized CaTiO 3 films on NdGaO 3 (110) substrates in a layer-by-layer way by pulsed laser deposition. The structural and electronic properties of the films were characterized by reflection-high-energy-electron-diffraction, X-ray diffraction, and element-specific resonant X-ray absorption spectroscopy. To reveal the orbital polarization and the crystal field splitting of the titanium 3d state, X-ray linear dichroism was carried out on CaTiO 3 films, demonstrating the orbital configuration of dmore » xz/d yz < d xy < d 3z2-r2 < d x2-y2. To further explore the origin of this configuration, we performed the first-principles density function theory calculations, which linked the orbital occupation to the on-site energy of Ti 3d orbitals. Finally, these findings can be important for understanding and designing exotic quantum states in heterostructures based on CaTiO 3.« less

  9. Two-dimensional confinement of 3d{1} electrons in LaTiO_{3}/LaAlO{3} multilayers.

    PubMed

    Seo, S S A; Han, M J; Hassink, G W J; Choi, W S; Moon, S J; Kim, J S; Susaki, T; Lee, Y S; Yu, J; Bernhard, C; Hwang, H Y; Rijnders, G; Blank, D H A; Keimer, B; Noh, T W

    2010-01-22

    We report spectroscopic ellipsometry measurements of the anisotropy of the interband transitions parallel and perpendicular to the planes of (LaTiO3)n(LaAlO3)5 multilayers with n=1-3. These provide direct information about the electronic structure of the two-dimensional (2D) 3d{1} state of the Ti ions. In combination with local density approximation, including a Hubbard U calculation, we suggest that 2D confinement in the TiO2 slabs lifts the degeneracy of the t{2g} states leaving only the planar d{xy} orbitals occupied. We outline that these multilayers can serve as a model system for the study of the t{2g} 2D Hubbard model.

  10. Anomalous resistivity and superconductivity in the two-band Hubbard model with one narrow band (Review)

    NASA Astrophysics Data System (ADS)

    Kagan, M. Yu.; Valkov, V. V.

    2011-01-01

    We search for marginal Fermi-liquid behavior in the two-band Hubbard model with one narrow band. We consider the limit of low electron densities in the bands and strong intraband and interband Hubbard interactions. We analyze the influence of electron-polaron effects and other mechanisms for mass-enhancement (related to the momentum dependence of the self-energies) on the effective mass and scattering times of light and heavy components in the clean case (electron-electron scattering and no impurities). We find a tendency towards phase separation (towards negative partial compressibility of heavy particles) in the 3D case with a large mismatch between the densities of heavy and light bands in the strong coupling limit. We also find that for low temperatures and equal densities, the resistivity in a homogeneous state R(T )∝T2 behaves as a Fermi-liquid in both 3D and 2D. For temperatures greater than the effective bandwidth for heavy electrons T >Wh*, the coherence of the heavy component breaks down completely. The heavy particles move diffusively in the surrounding light particles. At the same time, light particles scatter on heavy particles as if on immobile (static) impurities. Under these conditions, the heavy component is marginal, while the light component is not. The resistivity approaches saturation for T >Wh* in the 3D case. In 2D the resistivity has a maximum and a localization tail owing to weak-localization corrections of the Altshuler-Aronov type. This behavior of resistivity in 3D could be relevant for some uranium-based heavy-fermion compounds such as UNi2Al3 and in 2D, for some other mixed-valence compounds, possibly including layered manganites. We also consider briefly the superconductive (SC) instability in this model. The leading instability tends to p-wave pairing and is governed by an enhanced Kohn-Luttinger mechanism for SC at low electron densities. The critical temperature corresponds to the pairing of heavy electrons via polarization of the light electrons in 2D.

  11. Electron Heating and Acceleration in a Reconnecting Magnetotail

    NASA Astrophysics Data System (ADS)

    El-Alaoui, M.; Zhou, M.; Lapenta, G.; Berchem, J.; Richard, R. L.; Schriver, D.; Walker, R. J.

    2017-12-01

    Electron heating and acceleration in the magnetotail have been investigated intensively. A major site for this process is the reconnection region. However, where and how the electrons are accelerated in a realistic three-dimensional X-line geometry is not fully understood. In this study, we employed a three-dimensional implicit particle-in-cell (iPIC3D) simulation and large-scale kinetic (LSK) simulation to address these problems. We modeled a magnetotail reconnection event observed by THEMIS in an iPIC3D simulation with initial and boundary conditions given by a global magnetohydrodynamic (MHD) simulation of Earth's magnetosphere. The iPIC3D simulation system includes the region of fast outflow emanating from the reconnection site that drives dipolarization fronts. We found that current sheet electrons exhibit elongated (cigar-shaped) velocity distributions with a higher parallel temperature. Using LSK we then followed millions of test electrons using the electromagnetic fields from iPIC3D. We found that magnetotail reconnection can generate power law spectra around the near-Earth X-line. A significant number of electrons with energies higher than 50 keV are produced. We identified several acceleration mechanisms at different locations that were responsible for energizing these electrons: non-adiabatic cross-tail drift, betatron and Fermi acceleration. Relative contributions to the energy gain of these high energy electrons from the different mechanisms will be discussed.

  12. 3D-hybrid material design with electron/lithium-ion dual-conductivity for high-performance Li-sulfur batteries

    NASA Astrophysics Data System (ADS)

    Zhao, Yan; Tan, Rui; Yang, Jie; Wang, Kai; Gao, Rongtan; Liu, Dong; Liu, Yidong; Yang, Jinlong; Pan, Feng

    2017-02-01

    We report a novel 3D-hybrid cathode material with three-dimensional (3D) N-GO/CNT framework to load sulfur (77.6 wt %), and sulfonated polyaniline (SPANI) of coating layer. Used as a cathode material, it possesses a high capacity (1196 mAh g-1@0.3 A g-1@1.6 mg cm-2), excellent charging-discharging rate (680 mAh g-1@7.5 A g-1) and long-life performance (maintaining 71.1% capacity over 450 cycles), which is mainly attributed to the benefits of excellent electronic/Li-ionic dual-conductivity and confinement effect of the 3D-hybrid N-GO/CNT framework coated by self-doping conducting polymer SPANI. Thus, a 3D sulfur cathode modified with electronic/Li-ionic dual-conduction network can significantly enhance the electrochemical performance and stability, and this novel type of material is very promising for commercial applications that require high energy and power density, long life, and excellent abuse tolerance.

  13. Using Quasi-3D OSIRIS simulations of LWFA to study generating high brightness electron beams using ionization and density downramp injection

    NASA Astrophysics Data System (ADS)

    Dalichaouch, Thamine; Davidson, Asher; Xu, Xinlu; Yu, Peicheng; Tsung, Frank; Mori, Warren; Li, Fei; Zhang, Chaojie; Lu, Wei; Vieira, Jorge; Fonseca, Ricardo

    2016-10-01

    In the past few decades, there has been much progress in theory, simulation, and experiment towards using Laser wakefield acceleration (LWFA) as the basis for designing and building compact x-ray free-electron-lasers (XFEL) as well as a next generation linear collider. Recently, ionization injection and density downramp injection have been proposed and demonstrated as a controllable injection scheme for creating higher quality and ultra-bright relativistic electron beams using LWFA. However, full-3D simulations of plasma-based accelerators are computationally intensive, sometimes taking 100 millions of core-hours on today's computers. A more efficient quasi-3D algorithm was developed and implemented into OSIRIS using a particle-in-cell description with a charge conserving current deposition scheme in r - z and a gridless Fourier expansion in ϕ. Due to the azimuthal symmetry in LWFA, quasi-3D simulations are computationally more efficient than 3D cartesian simulations since only the first few harmonics in are needed ϕ to capture the 3D physics of LWFA. Using the quasi-3D approach, we present preliminary results of ionization and down ramp triggered injection and compare the results against 3D LWFA simulations. This work was supported by DOE and NSF.

  14. Physically motivated global alignment method for electron tomography

    DOE PAGES

    Sanders, Toby; Prange, Micah; Akatay, Cem; ...

    2015-04-08

    Electron tomography is widely used for nanoscale determination of 3-D structures in many areas of science. Determining the 3-D structure of a sample from electron tomography involves three major steps: acquisition of sequence of 2-D projection images of the sample with the electron microscope, alignment of the images to a common coordinate system, and 3-D reconstruction and segmentation of the sample from the aligned image data. The resolution of the 3-D reconstruction is directly influenced by the accuracy of the alignment, and therefore, it is crucial to have a robust and dependable alignment method. In this paper, we develop amore » new alignment method which avoids the use of markers and instead traces the computed paths of many identifiable ‘local’ center-of-mass points as the sample is rotated. Compared with traditional correlation schemes, the alignment method presented here is resistant to cumulative error observed from correlation techniques, has very rigorous mathematical justification, and is very robust since many points and paths are used, all of which inevitably improves the quality of the reconstruction and confidence in the scientific results.« less

  15. Recombination of H(3+) and D(3+) ions with electrons

    NASA Technical Reports Server (NTRS)

    Johnsen, R.; Gougousi, T.; Golde, M. F.

    1994-01-01

    Flowing-afterglow measurements in decaying H3(+) or D3(+) plasmas suggest that de-ionization does not occur by simple binary recombination of a single ion species. We find that vibrational excitation of the ions fails to provide an explanation for the effect, contrary to an earlier suggestion. Instead, we suggest that collisional stabilization of H3** Rydberg molecules by ambient electrons introduces an additional dependence on electron density. The proposed mechanism would permit plasma de-ionization to occur without the need for dissociative recombination by the mechanism of potential-surface crossings.

  16. 3D Printing Multi-Functionality: Embedded RF Antennas and Components

    NASA Technical Reports Server (NTRS)

    Shemelya, C. M.; Zemba, M.; Liang, M.; Espalin, D.; Kief, C.; Xin, H.; Wicker, R. B.; MacDonald, E. W.

    2015-01-01

    Significant research and press has recently focused on the fabrication freedom of Additive Manufacturing (AM) to create both conceptual models and final end-use products. This flexibility allows design modifications to be immediately reflected in 3D printed structures, creating new paradigms within the manufacturing process. 3D printed products will inevitably be fabricated locally, with unit-level customization, optimized to unique mission requirements. However, for the technology to be universally adopted, the processes must be enhanced to incorporate additional technologies; such as electronics, actuation, and electromagnetics. Recently, a novel 3D printing platform, Multi3D manufacturing, was funded by the presidential initiative for revitalizing manufacturing in the USA using 3D printing (America Makes - also known as the National Additive Manufacturing Innovation Institute). The Multi3D system specifically targets 3D printed electronics in arbitrary form; and building upon the potential of this system, this paper describes RF antennas and components fabricated through the integration of material extrusion 3D printing with embedded wire, mesh, and RF elements.

  17. Anomalous resistivity and the origin of heavy mass in the two-band Hubbard model with one narrow band

    NASA Astrophysics Data System (ADS)

    Kagan, M. Yu.; Val'kov, V. V.

    2011-07-01

    We search for marginal Fermi-liquid behavior [1] in the two-band Hubbard model with one narrow band. We consider the limit of low electron densities in the bands and strong intraband and interband Hubbard interactions. We analyze the influence of electron polaron effect [2] and other mechanisms of mass enhancement (related to momentum dependence of the self-energies) on the effective mass and scattering times of light and heavy components in the clean case (electron-electron scattering and no impurities). We find the tendency towards phase separation (towards negative partial compressibility of heavy particles) in the 3D case for a large mismatch between the densities of heavy and light bands in the strong-coupling limit. We also observe that for low temperatures and equal densities, the homogeneous state resistivity R( T) ˜ T 2 behaves in a Fermi-liquid fashion in both 3D and 2D cases. For temperatures higher than the effective bandwidth for heavy electrons T > W {*/ h }, the coherent behavior of the heavy component is totally destroyed. The heavy particles move diffusively in the surrounding of light particles. At the same time, the light particles scatter on the heavy ones as if on immobile (static) impurities. In this regime, the heavy component is marginal, while the light one is not. The resistivity saturates for T > W {*/ h } in the 3D case. In 2D, the resistivity has a maximum and a localization tail due to weak-localization corrections of the Altshuler-Aronov type [3]. Such behavior of resistivity could be relevant for some uranium-based heavy-fermion compounds like UNi2Al3 in 3D and for some other mixed-valence compounds possibly including layered manganites in 2D. We also briefly consider the superconductive (SC) instability in the model. The leading instability is towards the p-wave pairing and is governed by the enhanced Kohn-Luttinger [4] mechanism of SC at low electron density. The critical temperature corresponds to the pairing of heavy electrons via polarization of the light ones in 2D.

  18. Magnetic susceptibilities of actinide 3d-metal intermetallic compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muniz, R.B.; d'Albuquerque e Castro, J.; Troper, A.

    1988-04-15

    We have numerically calculated the magnetic susceptibilities which appear in the Hartree--Fock instability criterion for actinide 3d transition-metal intermetallic compounds. This calculation is based on a previous tight-binding description of these actinide-based compounds (A. Troper and A. A. Gomes, Phys. Rev. B 34, 6487 (1986)). The parameters of the calculation, which starts from simple tight-binding d and f bands are (i) occupation numbers, (ii) ratio of d-f hybridization to d bandwidth, and (iii) electron-electron Coulomb-type interactions.

  19. Electronic structure, local magnetism, and spin-orbit effects of Ir(IV)-, Ir(V)-, and Ir(VI)-based compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laguna-Marco, M. A.; Kayser, P.; Alonso, J. A.

    2015-06-01

    Element- and orbital-selective x-ray absorption and magnetic circular dichroism measurements are carried out to probe the electronic structure and magnetism of Ir 5d electronic states in double perovskite Sr2MIrO6 (M = Mg, Ca, Sc, Ti, Ni, Fe, Zn, In) and La2NiIrO6 compounds. All the studied systems present a significant influence of spin-orbit interactions in the electronic ground state. In addition, we find that the Ir 5d local magnetic moment shows different character depending on the oxidation state despite the net magnetization being similar for all the compounds. Ir carries an orbital contribution comparable to the spin contribution for Ir4+ (5d(5))more » and Ir5+ (5d(4)) oxides, whereas the orbital contribution is quenched for Ir6+ (5d(3)) samples. Incorporation of a magnetic 3d atom allows getting insight into the magnetic coupling between 5d and 3d transition metals. Together with previous susceptibility and neutron diffractionmeasurements, the results indicate that Ir carries a significant local magnetic moment even in samples without a 3d metal. The size of the (small) net magnetization of these compounds is a result of predominant antiferromagnetic interactions between local moments coupled with structural details of each perovskite structure« less

  20. Color Stability of Heat-cure Acrylic Resin Subjected to Simulated Short-term Immersion in Fast-acting Denture Cleansers.

    PubMed

    Lohitha, K; Prakash, M; Gopinadh, A; Sai Sankar, A J; Sandeep, C H; Sreedevi, B

    2016-01-01

    Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat-cure denture base resin. The aim of the present study was to evaluate the effect of commercially available fast-acting denture cleansers on the color stability of heat-cure denture base resin at different time intervals. Thirty-six heat-cure acrylic resin (Ivoclar Triplex Hot-V) specimens are randomly allocated into four groups - Group A (distilled water as control); Group B (polident - 3 min); Group C (fixodent scope plus); and Group D (stain away plus) comprising of nine samples each. After recording the baseline values, the specimens were immersed in their respective cleansing solutions for a prescribed time interval. This procedure was repeated daily, and the color change (ΔE) was evaluated after 90 and 180 days interval using a colorimeter in a standard "Commission International de l'Eclairage" color system. Paired t -test and Dunnett's T3 test. All the groups exhibited a variable color change (ΔE) for an immersion period of 90 days. However, significant color differences ( P = 0.001) were noticed among the test groups after 180 days. The color change of denture base resin was greater for Group D followed by Groups B, C, and A respectively after 180 days of immersion. The ΔE values of all test groups increased with time.

  1. Effect of ammonia and methane adsorption on the electronic structure of undoped and Fe-doped 2D silica: a first-principles calculation

    NASA Astrophysics Data System (ADS)

    Chibisov, A. N.; Chibisova, M. A.

    2018-05-01

    Two-dimensional silicon oxide (2D SiO2) is a unique surface phase with interesting optical, structural and electronic properties. In this study, important novel results on the effect of Fe on the structural and electronic properties of 2D SiO2 during adsorption of CH4 and NH3 molecules are presented. Density functional theory calculations are used to investigate the interaction of CH4 and NH3 molecules with silica. The electronic structure and molecules adsorption energy are studied in detail for undoped and Fe-doped surfaces. The results show that adsorption of CH4 and NH3 molecules on the surface decreases the spin polarization of Fe/SiO2. The results are relevant to understanding the adsorption physics of 2D SiO2 for practical usage in modern nanoelectronic sensors for nanotechnology and optoelectronics.

  2. Electron impact excitation rate coefficients for P-like Ni XIV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, K.; Shanghai EBIT Lab, Institute of Modern Physics, Department of Nuclear Science and Technology, Fudan University, Shanghai 200433; Yan, J.

    2012-07-15

    We have calculated the atomic data including electron impact excitations and radiative decays among the lowest 143 fine-structure levels arising from 3s{sup 2}3p{sup 3}, 3s3p{sup 4}, 3s{sup 2}3p{sup 2}3d, 3p{sup 5}, 3s3p{sup 3}3d, and 3s{sup 2}3p3d{sup 2} configurations in P-like Ni XIV. Direct excitation collision strengths are calculated employing the relativistic distorted-wave method. Resonances are included via the isolated resonance approximation using distorted-waves. Resonance contributions from S-like [3s{sup 2}3p{sup 3}, 3s3p{sup 4}, 3s{sup 2}3p{sup 2}3d,3p{sup 5}, 3s3p{sup 3}3d,3s{sup 2}3p3d{sup 2}, 3p{sup 4}3d,3s3p{sup 2}3d{sup 2},3s{sup 2}3d{sup 3}]n{sup Prime }l{sup Prime} complex series are taken into account. Effective collision strengths are reportedmore » over an electron temperature range of 1.0 Multiplication-Sign 10{sup 5}-1.0 Multiplication-Sign 10{sup 8} K. -- Highlights: Black-Right-Pointing-Pointer Radiative and collisional atomic data are presented for the lowest 143 fine-structure levels in P-like Ni XIV. Black-Right-Pointing-Pointer Calculations are performed using the FAC package. Black-Right-Pointing-Pointer Resonances enhance significantly a large amount of transitions. Black-Right-Pointing-Pointer Resonances play an important role of level population and line intensity ratios.« less

  3. 21 CFR 524.2101 - Selenium disulfide suspension.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...

  4. 21 CFR 524.2101 - Selenium disulfide suspension.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...

  5. 21 CFR 524.2101 - Selenium disulfide suspension.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...

  6. 21 CFR 524.2101 - Selenium disulfide suspension.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...

  7. 21 CFR 524.2101 - Selenium disulfide suspension.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... use as a cleansing shampoo and as an agent for removing skin debris associated with dry eczema... carefully around scrotum and eyes, covering scrotum with petrolatum. Allow the shampoo to remain for 5 to 15...

  8. 30 CFR 47.11 - Definitions of terms used in this part.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... drugs (1) Cosmetics are any article applied to the human body for cleansing, beautifying, promoting... the body of humans or other animals. CPSC The U.S. Consumer Product Safety Commission. Designated...

  9. 30 CFR 47.11 - Definitions of terms used in this part.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... drugs (1) Cosmetics are any article applied to the human body for cleansing, beautifying, promoting... the body of humans or other animals. CPSC The U.S. Consumer Product Safety Commission. Designated...

  10. Do-It-Yourself: 3D Models of Hydrogenic Orbitals through 3D Printing

    ERIC Educational Resources Information Center

    Griffith, Kaitlyn M.; de Cataldo, Riccardo; Fogarty, Keir H.

    2016-01-01

    Introductory chemistry students often have difficulty visualizing the 3-dimensional shapes of the hydrogenic electron orbitals without the aid of physical 3D models. Unfortunately, commercially available models can be quite expensive. 3D printing offers a solution for producing models of hydrogenic orbitals. 3D printing technology is widely…

  11. A Simple, Low-Cost Conductive Composite Material for 3D Printing of Electronic Sensors

    PubMed Central

    Leigh, Simon J.; Bradley, Robert J.; Purssell, Christopher P.; Billson, Duncan R.; Hutchins, David A.

    2012-01-01

    3D printing technology can produce complex objects directly from computer aided digital designs. The technology has traditionally been used by large companies to produce fit and form concept prototypes (‘rapid prototyping’) before production. In recent years however there has been a move to adopt the technology as full-scale manufacturing solution. The advent of low-cost, desktop 3D printers such as the RepRap and Fab@Home has meant a wider user base are now able to have access to desktop manufacturing platforms enabling them to produce highly customised products for personal use and sale. This uptake in usage has been coupled with a demand for printing technology and materials able to print functional elements such as electronic sensors. Here we present formulation of a simple conductive thermoplastic composite we term ‘carbomorph’ and demonstrate how it can be used in an unmodified low-cost 3D printer to print electronic sensors able to sense mechanical flexing and capacitance changes. We show how this capability can be used to produce custom sensing devices and user interface devices along with printed objects with embedded sensing capability. This advance in low-cost 3D printing with offer a new paradigm in the 3D printing field with printed sensors and electronics embedded inside 3D printed objects in a single build process without requiring complex or expensive materials incorporating additives such as carbon nanotubes. PMID:23185319

  12. Fragility of ferromagnetic double exchange interactions and pressure tuning of magnetism in 3 d -5 d double perovskite Sr2FeOsO6

    NASA Astrophysics Data System (ADS)

    Veiga, L. S. I.; Fabbris, G.; van Veenendaal, M.; Souza-Neto, N. M.; Feng, H. L.; Yamaura, K.; Haskel, D.

    2015-06-01

    The ability to tune exchange (magnetic) interactions between 3 d transition metals in perovskite structures has proven to be a powerful route to discovery of novel properties. Here we demonstrate that the introduction of 3 d -5 d exchange pathways in double perovskites enables additional tunability, a result of the large spatial extent of 5 d wave functions. Using x-ray probes of magnetism and structure at high pressure, we show that compression of Sr2FeOsO6 drives an unexpected continuous change in the sign of Fe-Os exchange interactions and a transition from antiferromagnetic to ferrimagnetic order. We analyze the relevant electron-electron interactions, shedding light into fundamental differences with the more thoroughly studied 3 d -3 d systems.

  13. Effect of 3d doping on the electronic structure of BaFe2As2.

    PubMed

    McLeod, J A; Buling, A; Green, R J; Boyko, T D; Skorikov, N A; Kurmaev, E Z; Neumann, M; Finkelstein, L D; Ni, N; Thaler, A; Bud'ko, S L; Canfield, P C; Moewes, A

    2012-05-30

    The electronic structure of BaFe(2)As(2) doped with Co, Ni and Cu has been studied by a variety of experimental and theoretical methods, but a clear picture of the dopant 3d states has not yet emerged. Herein we provide experimental evidence of the distribution of Co, Ni and Cu 3d states in the valence band. We conclude that the Co and Ni 3d states provide additional free carriers to the Fermi level, while the Cu 3d states are found at the bottom of the valence band in a localized 3d(10) shell. These findings help shed light on why superconductivity can occur in BaFe(2)As(2) doped with Co and Ni but not Cu.

  14. The flash-quench technique in protein-DNA electron transfer: reduction of the guanine radical by ferrocytochrome c.

    PubMed

    Stemp, E D; Barton, J K

    2000-08-21

    Electron transfer from a protein to oxidatively damaged DNA, specifically from ferrocytochrome c to the guanine radical, was examined using the flash-quench technique. Ru(phen)2dppz2+ (dppz = dipyridophenazine) was employed as the photosensitive intercalator, and ferricytochrome c (Fe3+ cyt c), as the oxidative quencher. Using transient absorption and time-resolved luminescence spectroscopies, we examined the electron-transfer reactions following photoexcitation of the ruthenium complex in the presence of poly(dA-dT) or poly(dG-dC). The luminescence-quenching titrations of excited Ru(phen)2dppz2+ by Fe3+ cyt c are nearly identical for the two DNA polymers. However, the spectral characteristics of the long-lived transient produced by the quenching depend strongly upon the DNA. For poly(dA-dT), the transient has a spectrum consistent with formation of a [Ru(phen)2dppz3+, Fe2+ cyt c] intermediate, indicating that the system regenerates itself via electron transfer from the protein to the Ru(III) metallointercalator for this polymer. For poly(dG-dC), however, the transient has the characteristics expected for an intermediate of Fe2+ cyt c and the neutral guanine radical. The characteristics of the transient formed with the GC polymer are consistent with rapid oxidation of guanine by the Ru(III) complex, followed by slow electron transfer from Fe2+ cyt c to the guanine radical. These experiments show that electron holes on DNA can be repaired by protein and demonstrate how the flash-quench technique can be used generally in studying electron transfer from proteins to guanine radicals in duplex DNA.

  15. Three-dimensional structural dynamics of DNA origami Bennett linkages using individual-particle electron tomography

    DOE PAGES

    Lei, Dongsheng; Marras, Alexander E.; Liu, Jianfang; ...

    2018-02-09

    Scaffolded DNA origami has proven to be a powerful and efficient technique to fabricate functional nanomachines by programming the folding of a single-stranded DNA template strand into three-dimensional (3D) nanostructures, designed to be precisely motion-controlled. Although two-dimensional (2D) imaging of DNA nanomachines using transmission electron microscopy and atomic force microscopy suggested these nanomachines are dynamic in 3D, geometric analysis based on 2D imaging was insufficient to uncover the exact motion in 3D. In this paper, we use the individual-particle electron tomography method and reconstruct 129 density maps from 129 individual DNA origami Bennett linkage mechanisms at ~6-14 nm resolution. The statisticalmore » analyses of these conformations lead to understanding the 3D structural dynamics of Bennett linkage mechanisms. Moreover, our effort provides experimental verification of a theoretical kinematics model of DNA origami, which can be used as feedback to improve the design and control of motion via optimized DNA sequences and routing.« less

  16. Three-dimensional structural dynamics of DNA origami Bennett linkages using individual-particle electron tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lei, Dongsheng; Marras, Alexander E.; Liu, Jianfang

    Scaffolded DNA origami has proven to be a powerful and efficient technique to fabricate functional nanomachines by programming the folding of a single-stranded DNA template strand into three-dimensional (3D) nanostructures, designed to be precisely motion-controlled. Although two-dimensional (2D) imaging of DNA nanomachines using transmission electron microscopy and atomic force microscopy suggested these nanomachines are dynamic in 3D, geometric analysis based on 2D imaging was insufficient to uncover the exact motion in 3D. In this paper, we use the individual-particle electron tomography method and reconstruct 129 density maps from 129 individual DNA origami Bennett linkage mechanisms at ~6-14 nm resolution. The statisticalmore » analyses of these conformations lead to understanding the 3D structural dynamics of Bennett linkage mechanisms. Moreover, our effort provides experimental verification of a theoretical kinematics model of DNA origami, which can be used as feedback to improve the design and control of motion via optimized DNA sequences and routing.« less

  17. Seamless lamination of a concave-convex architecture with single-layer graphene.

    PubMed

    Park, Ji-Hoon; Lim, Taekyung; Baik, Jaeyoon; Seo, Keumyoung; Moon, Youngkwon; Park, Noejung; Shin, Hyun-Joon; Kwak, Sang Kyu; Ju, Sanghyun; Ahn, Joung Real

    2015-11-21

    Graphene has been used as an electrode and channel material in electronic devices because of its superior physical properties. Recently, electronic devices have changed from a planar to a complicated three-dimensional (3D) geometry to overcome the limitations of planar devices. The evolution of electronic devices requires that graphene be adaptable to a 3D substrate. Here, we demonstrate that chemical-vapor-deposited single-layer graphene can be transferred onto a silicon dioxide substrate with a 3D geometry, such as a concave-convex architecture. A variety of silicon dioxide concave-convex architectures were uniformly and seamlessly laminated with graphene using a thermal treatment. The planar graphene was stretched to cover the concave-convex architecture, and the resulting strain on the curved graphene was spatially resolved by confocal Raman spectroscopy; molecular dynamic simulations were also conducted and supported the observations. Changes in electrical resistivity caused by the spatially varying strain induced as the graphene-silicon dioxide laminate varies dimensionally from 2D to 3D were measured by using a four-point probe. The resistivity measurements suggest that the electrical resistivity can be systematically controlled by the 3D geometry of the graphene-silicon dioxide laminate. This 3D graphene-insulator laminate will broaden the range of graphene applications beyond planar structures to 3D materials.

  18. Recent advances in the application of electron tomography to materials chemistry.

    PubMed

    Leary, Rowan; Midgley, Paul A; Thomas, John Meurig

    2012-10-16

    Nowadays, tomography plays a central role in pureand applied science, in medicine, and in many branches of engineering and technology. It entails reconstructing the three-dimensional (3D) structure of an object from a tilt series of two-dimensional (2D) images. Its origin goes back to 1917, when Radon showed mathematically how a series of 2D projection images could be converted to the 3D structural one. Tomographic X-ray and positron scanning for 3D medical imaging, with a resolution of ∼1 mm, is now ubiquitous in major hospitals. Electron tomography, a relatively new chemical tool, with a resolution of ∼1 nm, has been recently adopted by materials chemists as an invaluable aid for the 3D study of the morphologies, spatially-discriminating chemical compositions, and defect properties of nanostructured materials. In this Account, we review the advances that have been made in facilitating the recording of the required series of 2D electron microscopic images and the subsequent process of 3D reconstruction of specimens that are vulnerable, to a greater or lesser degree, to electron beam damage. We describe how high-fidelity 3D tomograms may be obtained from relatively few 2D images by incorporating prior structural knowledge into the reconstruction process. In particular, we highlight the vital role of compressed sensing, a recently developed procedure well-known to information theorists that exploits ideas of image compression and "sparsity" (that the important image information can be captured in a reduced data set). We also touch upon another promising approach, "discrete" tomography, which builds into the reconstruction process a prior assumption that the object can be described in discrete terms, such as the number of constituent materials and their expected densities. Other advances made recently that we outline, such as the availability of aberration-corrected electron microscopes, electron wavelength monochromators, and sophisticated specimen goniometers, have all contributed significantly to the further development of quantitative 3D studies of nanostructured materials, including nanoparticle-heterogeneous catalysts, fuel-cell components, and drug-delivery systems, as well as photovoltaic and plasmonic devices, and are likely to enhance our knowledge of many other facets of materials chemistry, such as organic-inorganic composites, solar-energy devices, bionanotechnology, biomineralization, and energy-storage systems composed of high-permittivity metal oxides.

  19. Towards 3D crystal orientation reconstruction using automated crystal orientation mapping transmission electron microscopy (ACOM-TEM).

    PubMed

    Kobler, Aaron; Kübel, Christian

    2018-01-01

    To relate the internal structure of a volume (crystallite and phase boundaries) to properties (electrical, magnetic, mechanical, thermal), a full 3D reconstruction in combination with in situ testing is desirable. In situ testing allows the crystallographic changes in a material to be followed by tracking and comparing the individual crystals and phases. Standard transmission electron microscopy (TEM) delivers a projection image through the 3D volume of an electron-transparent TEM sample lamella. Only with the help of a dedicated TEM tomography sample holder is an accurate 3D reconstruction of the TEM lamella currently possible. 2D crystal orientation mapping has become a standard method for crystal orientation and phase determination while 3D crystal orientation mapping have been reported only a few times. The combination of in situ testing with 3D crystal orientation mapping remains a challenge in terms of stability and accuracy. Here, we outline a method to 3D reconstruct the crystal orientation from a superimposed diffraction pattern of overlapping crystals without sample tilt. Avoiding the typically required tilt series for 3D reconstruction enables not only faster in situ tests but also opens the possibility for more stable and more accurate in situ mechanical testing. The approach laid out here should serve as an inspiration for further research and does not make a claim to be complete.

  20. The separation of vibrational coherence from ground- and excited-electronic states in P3HT film

    NASA Astrophysics Data System (ADS)

    Song, Yin; Hellmann, Christoph; Stingelin, Natalie; Scholes, Gregory D.

    2015-06-01

    Concurrence of the vibrational coherence and ultrafast electron transfer has been observed in polymer/fullerene blends. However, it is difficult to experimentally investigate the role that the excited-state vibrational coherence plays during the electron transfer process since vibrational coherence from the ground- and excited-electronic states is usually temporally and spectrally overlapped. Here, we performed 2-dimensional electronic spectroscopy (2D ES) measurements on poly(3-hexylthiophene) (P3HT) films. By Fourier transforming the whole 2D ES datasets ( S ( λ 1 , T ˜ 2 , λ 3 ) ) along the population time ( T ˜ 2 ) axis, we develop and propose a protocol capable of separating vibrational coherence from the ground- and excited-electronic states in 3D rephasing and nonrephasing beating maps ( S ( λ 1 , ν ˜ 2 , λ 3 ) ). We found that the vibrational coherence from pure excited electronic states appears at positive frequency ( + ν ˜ 2 ) in the rephasing beating map and at negative frequency ( - ν ˜ 2 ) in the nonrephasing beating map. Furthermore, we also found that vibrational coherence from excited electronic state had a long dephasing time of 244 fs. The long-lived excited-state vibrational coherence indicates that coherence may be involved in the electron transfer process. Our findings not only shed light on the mechanism of ultrafast electron transfer in organic photovoltaics but also are beneficial for the study of the coherence effect on photoexcited dynamics in other systems.

  1. Sensor fusion of phase measuring profilometry and stereo vision for three-dimensional inspection of electronic components assembled on printed circuit boards.

    PubMed

    Hong, Deokhwa; Lee, Hyunki; Kim, Min Young; Cho, Hyungsuck; Moon, Jeon Il

    2009-07-20

    Automatic optical inspection (AOI) for printed circuit board (PCB) assembly plays a very important role in modern electronics manufacturing industries. Well-developed inspection machines in each assembly process are required to ensure the manufacturing quality of the electronics products. However, generally almost all AOI machines are based on 2D image-analysis technology. In this paper, a 3D-measurement-method-based AOI system is proposed consisting of a phase shifting profilometer and a stereo vision system for assembled electronic components on a PCB after component mounting and the reflow process. In this system information from two visual systems is fused to extend the shape measurement range limited by 2pi phase ambiguity of the phase shifting profilometer, and finally to maintain fine measurement resolution and high accuracy of the phase shifting profilometer with the measurement range extended by the stereo vision. The main purpose is to overcome the low inspection reliability problem of 2D-based inspection machines by using 3D information of components. The 3D shape measurement results on PCB-mounted electronic components are shown and compared with results from contact and noncontact 3D measuring machines. Based on a series of experiments, the usefulness of the proposed sensor system and its fusion technique are discussed and analyzed in detail.

  2. 2D Ruddlesden-Popper Perovskites for Optoelectronics.

    PubMed

    Chen, Yani; Sun, Yong; Peng, Jiajun; Tang, Junhui; Zheng, Kaibo; Liang, Ziqi

    2018-01-01

    Conventional 3D organic-inorganic halide perovskites have recently undergone unprecedented rapid development. Yet, their inherent instabilities over moisture, light, and heat remain a crucial challenge prior to the realization of commercialization. By contrast, the emerging 2D Ruddlesden-Popper-type perovskites have recently attracted increasing attention owing to their great environmental stability. However, the research of 2D perovskites is just in their infancy. In comparison to 3D analogues, they are natural quantum wells with a much larger exciton binding energy. Moreover, their inner structural, dielectric, optical, and excitonic properties remain to be largely explored, limiting further applications. This review begins with an introduction to 2D perovskites, along with a detailed comparison to 3D counterparts. Then, a discussion of the organic spacer cation engineering of 2D perovskites is presented. Next, quasi-2D perovskites that fall between 3D and 2D perovskites are reviewed and compared. The unique excitonic properties, electron-phonon coupling, and polarons of 2D perovskites are then be revealed. A range of their (opto)electronic applications is highlighted in each section. Finally, a summary is given, and the strategies toward structural design, growth control, and photophysics studies of 2D perovskites for high-performance electronic devices are rationalized. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Theoretical electronic transition moments for the Ballik-Ramsay, Fox-Herzberg, and Swan systems of C2

    NASA Technical Reports Server (NTRS)

    Cooper, D. M.

    1981-01-01

    Electronic transition moments and their variation with internuclear separation are calculated for the Ballik-Ramsay (b 3 Sigma g - a 3 Pi u), Fox-Herzberg (e 3 Pi g-a 3 Pi u) and Swan (d 3 Pi g-a 3 Pi u) band systems of C2, which appear in a variety of terrestrial and astrophysical sources. Electronic wave functions of the a 3 Pi u, b 2 Sigma g -, d 3 Pi g and e 3 Pi g states of C2 are obtained by means of a self-consistent field plus configuration interaction calculation using an atomic basis of 46 Slater-type orbitals, and theoretical potential energy curves and spectroscopic constants for the four electronic states were computed. The results obtained for both the potential energy curves and electronic transition moments are found to be in good agreement with experimental data.

  4. Valence-electron configuration of Fe, Cr, and Ni in binary and ternary alloys from Kβ -to- Kα x-ray intensity ratios

    NASA Astrophysics Data System (ADS)

    Han, I.; Demir, L.

    2009-11-01

    Kβ -to- Kα x-ray intensity ratios of Fe, Cr, and Ni have been measured in pure metals and in alloys of FexNi1-x ( x=0.8 , 0.7, 0.6, 0.5, 0.4, 0.3, and 0.2), NixCr1-x ( x=0.8 , 0.6, 0.5, 0.4, and 0.2), FexCr1-x ( x=0.9 , 0.7, and 0.5), and FexCryNi1-(x+y) ( x=0.7-y=0.1 , x=0.5-y=0.2 , x=0.4-y=0.3 , x=0.3-y=0.3 , x=0.2-y=0.2 , and x=0.1-y=0.2 ) following excitation by 22.69 keV x rays from a 10 mCi C109d radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kβ -to- Kα x-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s,4p states of individual metal atoms.

  5. 2D-3D MIGRATION AND CONFORMATIONAL MULTIPLICATION OF CHEMICALS IN LARGE CHEMICAL INVENTORIES

    EPA Science Inventory

    Chemical interactions are three-dimensional (3D) in nature and require modeling chemicals as 3D entities. In turn, using 3D models of chemicals leads to the realization that a single 2D structure can have hundreds of different conformations, and the electronic properties of these...

  6. THE CELL CENTERED DATABASE PROJECT: AN UPDATE ON BUILDING COMMUNITY RESOURCES FOR MANAGING AND SHARING 3D IMAGING DATA

    PubMed Central

    Martone, Maryann E.; Tran, Joshua; Wong, Willy W.; Sargis, Joy; Fong, Lisa; Larson, Stephen; Lamont, Stephan P.; Gupta, Amarnath; Ellisman, Mark H.

    2008-01-01

    Databases have become integral parts of data management, dissemination and mining in biology. At the Second Annual Conference on Electron Tomography, held in Amsterdam in 2001, we proposed that electron tomography data should be shared in a manner analogous to structural data at the protein and sequence scales. At that time, we outlined our progress in creating a database to bring together cell level imaging data across scales, The Cell Centered Database (CCDB). The CCDB was formally launched in 2002 as an on-line repository of high-resolution 3D light and electron microscopic reconstructions of cells and subcellular structures. It contains 2D, 3D and 4D structural and protein distribution information from confocal, multiphoton and electron microscopy, including correlated light and electron microscopy. Many of the data sets are derived from electron tomography of cells and tissues. In the five years since its debut, we have moved the CCDB from a prototype to a stable resource and expanded the scope of the project to include data management and knowledge engineering. Here we provide an update on the CCDB and how it is used by the scientific community. We also describe our work in developing additional knowledge tools, e.g., ontologies, for annotation and query of electron microscopic data. PMID:18054501

  7. Multi-band Electronic Structure of Ferromagnetic CeRuPO

    NASA Astrophysics Data System (ADS)

    Takahashi, Masaya; Ootsuki, Daiki; Horio, Masafumi; Arita, Masashi; Namatame, Hirofumi; Taniguchi, Masaki; Saini, Naurang L.; Sugawara, Hitoshi; Mizokawa, Takashi

    2018-04-01

    We have studied the multi-band electronic structure of ferromagnetic CeRuPO (TC = 15 K) by means of angle-resolved photoemission spectroscopy (ARPES). The ARPES results show that three hole bands exist around the zone center and two of them cross the Fermi level (EF). Around the zone corner, two electron bands are observed and cross EF. These hole and electron bands, which can be assigned to the Ru 4d bands, are basically consistent with the band-structure calculation including their orbital characters. However, one of the electron bands with Ru 4d 3z2 - r2 character is strongly renormalized indicating correlation effect due to hybridization with the Ce 4f orbitals. The Ru 4d 3z2 - r2 band changes across TC suggesting that the out-of-plane 3z2 - r2 orbital channel plays essential roles in the ferromagnetism.

  8. Suppression of Allowed Transitions in Al-like Krypton (Kr23+) Due to the Presence of a Magnetic Dipole Transition in the 3s23p 2P Ground Term

    NASA Astrophysics Data System (ADS)

    Reader, Joseph; Podpaly, Yuri; Ralchenko, Yuri; Gillaspy, John

    2013-05-01

    Extreme ultraviolet spectra of highly charged krypton atoms were produced with an electron beam ion trap (EBIT) and recorded with a flat-field grazing-incidence spectrometer. The wavelength range was 3-18 nm. Wavelength calibration was provided by known lines of highly ionized Kr as well as spectra of C, O, Xe, and Ba. The observed spectra were interpreted with the aid of collisional-radiative modeling of the EBIT plasma. For the Al-like ion Kr23+ the allowed resonance lines 3s23p 2P-3s23d 2D exhibited extreme deviation from the normal ratios for lines of this multiplet. In particular, the 2P3/2-2D5/2 transition, normally the strongest, was observed to be the weakest. This effect was explained by the fact that in the low electron density environment of EBIT the 2D5/2 level is primarily populated by electron excitation from 2P3/2. However, the presence of a magnetic dipole M1 transition 3s23p 2P1/2-2P3/2 reduces the population of 2P3/2 and hence the population of 2D5/2. We are conducting further modeling with varying electron density to try to reproduce the observed line ratios. This could serve as a diagnostic tool for determining electron density in EBIT and fusion energy devices. Supported by Office of Fusion Energy Sciences of Dept. of Energy.

  9. Integrated solutions to SHM problems: an overview of SHM research at the LANL/UCSD engineering institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farrar, Charles; Park, Gyuhae; Farinholt, Kevin

    2010-12-08

    This seminar will provide an overview of structural health monitoring (SHM) research that is being undertaken at Los Alamos National Laboratory (LANL). The seminar will begin by stating that SHM should be viewed as an important component of the more comprehensive intelligent life-cycle engineering process. Then LANL's statistical pattern recognition paradigm for addressing SHM problems will be introduced and current research that is focused on each part of the paradigm will be discussed. In th is paradigm, the process can be broken down into four parts: (1) Operational Evaluation, (2) Data Acquisition and Cleansing, (3) Feature Extraction, and (4) Statisticalmore » Model Development for Feature Discrimination. When one attempts to apply this paradigm to data from real world structures, it quickly becomes apparent that the ability to cleanse, compress, normalize and fuse data to account for operational and environmental variability is a key implementation issue when addressing Parts 2-4 of this paradigm. This discussion will be followed by the introduction a new project entitled 'Intelligent Wind Turbines' which is the focus of much of our current SHM research . This summary will be followed by a discussion of issues that must be addressed if this technology is to make the transition from research to practice and new research directions that are emerging for SHM.« less

  10. Feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy.

    PubMed

    Zhou, Jieqiong; Tang, Xiaowei; Wang, Jing; Chen, Zhenyu; Wang, Xinying; Jiang, Bo

    2017-08-01

    Bowel preparation regimens for colon capsule endoscopy are not yet standardized since they are not well optimized. The aim of the present study was to evaluate the feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy. A total of 31 patients were prospectively enrolled. In the novel regimen, on the day prior to examination, a low-fiber diet was permitted, 5 mg mosapride citrate was administered twice (1 h prior to lunch and supper) and 1 l polyethylene glycol was administered in the evening. On the day of the examination, an additional 1 l polyethylene glycol, 5 mg mosapride citrate and 200 mg simethicone were administered before capsule ingestion. Polyethylene glycol booster (0.5 l) was administered twice, at 1 and 4 h following capsule ingestion. Colon cleansing levels, ileocecal valve transit time and completion rate were evaluated. A total of 29 patients were included in the final analysis, 90% of whom achieved adequate preparation of the overall colon. Ileocecal valve transit time was 2.35±0.82 h and completion rate was 79.3%. The results revealed that the novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy was feasible, with adequate colon cleansing and completion rates, and has the potential to be used as an alternative regimen.

  11. What's growing on your stethoscope? (And what you can do about it).

    PubMed

    Schroeder, Ariel; Schroeder, Maryellen A; D'Amico, Frank

    2009-08-01

    Studies have shown that rubbing alcohol pads on stethoscope diaphragms can reduce bacterial colonization, but alcohol pads are used infrequently used and not always available. We conducted a prospective, single-blinded study to investigate whether simultaneously scrubbing hands and stethoscope head with alcohol-based hand foam would significantly reduce bacterial counts on the stethoscope. Using their own stethoscope, participants imprinted the stethoscope head onto a chocolate agar plate, then used alcohol-based hand foam to cleanse their hands while simultaneously rubbing the stethoscope head. Once the stethoscope heads were dry, the participants imprinted their stethoscope heads onto a second plate. After 48 hours' incubation, we determined the bacterial counts for the prewash and post-wash plates, and compared the 2. We analyzed a total of 184 cultures (from 92 stethoscopes). Both the mean (28 prewash vs 3 post-wash, P=.001) and median (11 prewash vs 1 post-wash, P=.001) colony counts were significantly greater before being cleansed. Three methicillin-resistant Staphylococcus aureus (MRSA) colonies were identified in the prewash period; all were destroyed by the foam. The estimated number of hand washes needed to prevent 1 MRSA colony is 31 (95% confidence interval [CI], 18-89). Simultaneously using hand foam to clean hands and stethoscope heads reduces bacterial counts on stethoscopes. Further research is needed to determine whether this intervention can reduce morbidity and mortality associated with bacterial infection.

  12. Aggregate exposure modelling of zinc pyrithione in rinse-off personal cleansing products using a person-orientated approach with market share refinement.

    PubMed

    Tozer, Sarah A; Kelly, Seamus; O'Mahony, Cian; Daly, E J; Nash, J F

    2015-09-01

    Realistic estimates of chemical aggregate exposure are needed to ensure consumer safety. As exposure estimates are a critical part of the equation used to calculate acceptable "safe levels" and conduct quantitative risk assessments, methods are needed to produce realistic exposure estimations. To this end, a probabilistic aggregate exposure model was developed to estimate consumer exposure from several rinse off personal cleansing products containing the anti-dandruff preservative zinc pyrithione. The model incorporates large habits and practices surveys, containing data on frequency of use, amount applied, co-use along with market share, and combines these data at the level of the individual based on subject demographics to better estimate exposure. The daily-applied exposure (i.e., amount applied to the skin) was 3.79 mg/kg/day for the 95th percentile consumer. The estimated internal dose for the 95th percentile exposure ranged from 0.01-1.29 μg/kg/day after accounting for retention following rinsing and dermal penetration of ZnPt. This probabilistic aggregate exposure model can be used in the human safety assessment of ingredients in multiple rinse-off technologies (e.g., shampoo, bar soap, body wash, and liquid hand soap). In addition, this model may be used in other situations where refined exposure assessment is required to support a chemical risk assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Reduction of halo pin site morbidity with a new pin care regimen.

    PubMed

    Kazi, Hussain Anthony; de Matas, Marcus; Pillay, Robin

    2013-06-01

    A retrospective analysis of halo device associated morbidity over a 4-year period. To assess the impact of a new pin care regimen on halo pin site related morbidity. Halo orthosis treatment still has a role in cervical spine pathology, despite increasing possibilities of open surgical treatment. Published figures for pin site infection range from 12% to 22% with pin loosening from 7% to 50%. We assessed the outcome of a new pin care regimen on morbidity associated with halo spinal orthoses, using a retrospective cohort study from 2001 to 2004. In the last two years, our pin care regimen was changed. This involved pin site care using chlorhexidene & regular torque checking as part of a standard protocol. Previously, povidone iodine was used as skin preparation in theatre, followed by regular sterile saline cleansing when pin sites became encrusted with blood. There were 37 patients in the series, the median age was 49 (range, 22-83) and 20 patients were male. The overall infection rate prior to the new pin care protocol was 30% (n=6) and after the introduction, it dropped to 5.9% (n=1). This difference was statistically significant (p<0.05). Pin loosening occurred in one patient in the group prior to the formal pin care protocol (3%) and none thereafter. Reduced morbidity from halo use can be achieved with a modified pin cleansing and tightening regimen.

  14. Possible origin of photoconductivity in La0.7Ca0.3MnO3

    NASA Astrophysics Data System (ADS)

    Sagdeo, P. R.; Choudhary, R. J.; Phase, D. M.

    2010-01-01

    The effect of photon energy on the density of states near Fermi level of pulsed laser deposited La0.7Ca0.3MnO3 thin film has been studied to investigate the possible origin of change in the conductivity of these manganites upon photon exposure. For this purpose the photoelectron spectroscopy measurements were carried out using CSR beamline (BL-2) on Indus-1 synchrotron radiation source. The valance band spectra were measured at room temperature with photon energy ranging from 40 to 60 eV. We could see huge change in the density of states near Fermi level and this change is observed to be highest at 56 eV which is due to the resonance between Mn 3p to Mn 3d level. Our results suggest that the probability of electron transfer from deep Mn 3p level to Mn 3d-eg level is higher than that of Mn 3d-t2g level. It appears that this transfer of electron from deep Mn level to Mn 3d-eg level not only modifies the density of state near Fermi level but also changes the mobility of electrons by modifying the electron lattice coupling due to presence of Mn+3 Jahn-Teller ion.

  15. Observation of the quantum Hall effect in δ-doped SrTiO3

    PubMed Central

    Matsubara, Y.; Takahashi, K. S.; Bahramy, M. S.; Kozuka, Y.; Maryenko, D.; Falson, J.; Tsukazaki, A.; Tokura, Y.; Kawasaki, M.

    2016-01-01

    The quantum Hall effect is a macroscopic quantum phenomenon in a two-dimensional electron system. The two-dimensional electron system in SrTiO3 has sparked a great deal of interest, mainly because of the strong electron correlation effects expected from the 3d orbitals. Here we report the observation of the quantum Hall effect in a dilute La-doped SrTiO3-two-dimensional electron system, fabricated by metal organic molecular-beam epitaxy. The quantized Hall plateaus are found to be solely stemming from the low Landau levels with even integer-filling factors, ν=4 and 6 without any contribution from odd ν's. For ν=4, the corresponding plateau disappears on decreasing the carrier density. Such peculiar behaviours are proposed to be due to the crossing between the Landau levels originating from the two subbands composed of d orbitals with different effective masses. Our findings pave a way to explore unprecedented quantum phenomena in d-electron systems. PMID:27228903

  16. Differences in the skin surface pH and bacterial microflora due to the long-term application of synthetic detergent preparations of pH 5.5 and pH 7.0. Results of a crossover trial in healthy volunteers.

    PubMed

    Korting, H C; Hübner, K; Greiner, K; Hamm, G; Braun-Falco, O

    1990-01-01

    Skin cleansing preparations consisting of identical synthetic detergents but differing in pH-value (pH 5.5 and 7.0) were applied twice daily on the forehead and forearm of healthy volunteers in a randomized crossover trial. The skin surface pH was found to be significantly higher when the neutral preparation had been used, as was the propionibacterial count (p less than 0.05). The number of propionibacteria was significantly linked to the skin pH. Hence even minor differences in the pH of skin cleansing preparations seem to be of importance for the integrity of the skin surface. This should be taken into account when planning the formulation of optimal skin care products.

  17. The failures of root canal preparation with hand ProTaper.

    PubMed

    Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C; Tuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia

    2012-07-01

    The failures of root canal preparation are due to some anatomical deviation (canal in "C" or "S") and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Our study was made on technique errors while preparing the canal roots with hand ProTaper. Our study was made "in vitro" on 84 extracted teeth (molars, premolars, incisors and canines). The canal root of these teeth were cleansed and shaped with hand ProTaper by crown-down technique and canal irrigation with NaOCl(2,5%). The dental preparation control was made by X-ray. During canal root preparation some failures were observed like: canal root overinstrumentation, zipping and stripping phenomenon, discarded and/or fractured instruments. Hand ProTaper represents a revolutionary progress of endodontic treatment, but a deviation from accepted rules of canal root instrumentation can lead to failures of endodontic treatment.

  18. Dirty liberals! Reminders of physical cleanliness influence moral and political attitudes.

    PubMed

    Helzer, Erik G; Pizarro, David A

    2011-04-01

    Many moral codes place a special emphasis on bodily purity, and manipulations that directly target bodily purity have been shown to influence a variety of moral judgments. Across two studies, we demonstrated that reminders of physical purity influence specific moral judgments regarding behaviors in the sexual domain as well as broad political attitudes. In Study 1, individuals in a public setting who were given a reminder of physical cleansing reported being more politically conservative than did individuals who were not given such a reminder. In Study 2, individuals reminded of physical cleansing in the laboratory demonstrated harsher moral judgments toward violations of sexual purity and were more likely to report being politically conservative than control participants. Together, these experiments provide further evidence of a deep link between physical purity and moral judgment, and they offer preliminary evidence that manipulations of physical purity can influence general (and putatively stable) political attitudes.

  19. Deployment and testing of a second prototype expandable surgical chamber in microgravity

    NASA Technical Reports Server (NTRS)

    Markham, Sanford M.; Rock, John A.

    1991-01-01

    During microgravity exposure, two separate expandable surgical chambers were tested. Both chambers had been modified to fit the microgravity work station without extending over the sides of the table. Both chambers were attached to a portable laminar flow generator which served two purposes: to keep the chambers expanded during use; and to provide an operative area environment free of contamination. During the tests, the chambers were placed on various parts of a total body moulage to simulate management of several types of trauma. The tests consisted of cleansing contusions, debridement of burns, and suturing of lacerations. Also, indigo carmine dye was deliberately injected into the chamber during the tests to determine the ease of cleansing the chamber walls after contamination by escaping fluids. Upon completion of the tests, the expandable surgical chambers were deflated, folded, and placed in a flattened state back into their original containers for storage and later disposal. Results are briefly discussed.

  20. Sertralilne, paroxetine and venlafaxine in refugee post traumatic stress disorder with depression symptoms.

    PubMed

    Smajkić, A; Weine, S; Durić-Bijedić, Z; Boskailo, E; Lewis, J; Pavković, I

    2001-01-01

    The authors describe the use of three new antidepressants: Sertralilne, Paroxetine and Venlafaxine in treating Posttraumatic Stress Disorder and symptoms of Depression in adult Bosnian refugees victims of ethnic cleansing. 32 Bosnian refugees with PTSD and symptoms of Depression presenting for treatment of the mental health consequences of surviving ethnic cleansing, participated in a case series study. All subjects completed open trials of Sertraline (15), Paroxetine (12) or Venlafaxine (5), with standard clinical doses. Overall, Sertraline and Paroxetine yielded statistically significant improvement at 6 weeks in the total PTSD symptom severity, in each symptom cluster, in Beck Depression Inventory and in Global Assessment of Functioning. Venlafaxine produced statistically significant improvement at 6 weeks in the total PTSD symptom severity, in each symptom cluster and in Global Assessment of Functioning but did not yield significant improvement in symptoms of depression and had a high rate of side effects.

  1. Facile synthesis of 3D few-layered MoS2 coated TiO2 nanosheet core-shell nanostructures for stable and high-performance lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Chen, Biao; Zhao, Naiqin; Guo, Lichao; He, Fang; Shi, Chunsheng; He, Chunnian; Li, Jiajun; Liu, Enzuo

    2015-07-01

    Uniform transition metal sulfide deposition on a smooth TiO2 surface to form a coating structure is a well-known challenge, caused mainly due to their poor affinities. Herein, we report a facile strategy for fabricating mesoporous 3D few-layered (<4 layers) MoS2 coated TiO2 nanosheet core-shell nanocomposites (denoted as 3D FL-MoS2@TiO2) by a novel two-step method using a smooth TiO2 nanosheet as a template and glucose as a binder. The core-shell structure has been systematically examined and corroborated by transmission electron microscopy, scanning transmission electron microscopy, and X-ray photoelectron spectroscopy analyses. It is found that the resultant 3D FL-MoS2@TiO2 as a lithium-ion battery anode delivers an outstanding high-rate capability with an excellent cycling performance, relating to the unique structure of 3D FL-MoS2@TiO2. The 3D uniform coverage of few-layered (<4 layers) MoS2 onto the TiO2 can remarkably enhance the structure stability and effectively shortens the transfer paths of both lithium ions and electrons, while the strong synergistic effect between MoS2 and TiO2 can significantly facilitate the transport of ions and electrons across the interfaces, especially in the high-rate charge-discharge process. Moreover, the facile fabrication strategy can be easily extended to design other oxide/carbon-sulfide/oxide core-shell materials for extensive applications.Uniform transition metal sulfide deposition on a smooth TiO2 surface to form a coating structure is a well-known challenge, caused mainly due to their poor affinities. Herein, we report a facile strategy for fabricating mesoporous 3D few-layered (<4 layers) MoS2 coated TiO2 nanosheet core-shell nanocomposites (denoted as 3D FL-MoS2@TiO2) by a novel two-step method using a smooth TiO2 nanosheet as a template and glucose as a binder. The core-shell structure has been systematically examined and corroborated by transmission electron microscopy, scanning transmission electron microscopy, and X-ray photoelectron spectroscopy analyses. It is found that the resultant 3D FL-MoS2@TiO2 as a lithium-ion battery anode delivers an outstanding high-rate capability with an excellent cycling performance, relating to the unique structure of 3D FL-MoS2@TiO2. The 3D uniform coverage of few-layered (<4 layers) MoS2 onto the TiO2 can remarkably enhance the structure stability and effectively shortens the transfer paths of both lithium ions and electrons, while the strong synergistic effect between MoS2 and TiO2 can significantly facilitate the transport of ions and electrons across the interfaces, especially in the high-rate charge-discharge process. Moreover, the facile fabrication strategy can be easily extended to design other oxide/carbon-sulfide/oxide core-shell materials for extensive applications. Electronic supplementary information (ESI) available: Supplementary SEM, TEM, XPS and EIS analyses. See DOI: 10.1039/c5nr03334a

  2. X-ray Emission Spectroscopy in Magnetic 3d-Transition Metals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iota, V; Park, J; Baer, B

    2003-11-18

    The application of high pressure affects the band structure and magnetic interactions in solids by modifying nearest-neighbor distances and interatomic potentials. While all materials experience electronic changes with increasing pressure, spin polarized, strongly electron correlated materials are expected to undergo the most dramatic transformations. In such materials, (d and f-electron metals and compounds), applied pressure reduces the strength of on-site correlations, leading to increased electron delocalization and, eventually, to loss of its magnetism. In this ongoing project, we study the electronic and magnetic properties of Group VIII, 3d (Fe, Co and Ni) magnetic transition metals and their compounds at highmore » pressures. The high-pressure properties of magnetic 3d-transition metals and compounds have been studied extensively over the years, because of iron being a major constituent of the Earth's core and its relevance to the planetary modeling to understand the chemical composition, internal structure, and geomagnetism. However, the fundamental scientific interest in the high-pressure properties of magnetic 3d-electron systems extends well beyond the geophysical applications to include the electron correlation-driven physics. The role of magnetic interactions in the stabilization of the ''non-standard'' ambient pressure structures of Fe, Co and Ni is still incompletely understood. Theoretical studies have predicted (and high pressure experiments are beginning to show) strong correlations between the electronic structure and phase stability in these materials. The phase diagrams of magnetic 3d systems reflect a delicate balance between spin interactions and structural configuration. At ambient conditions, the crystal structures of {alpha}-Fe(bcc) and {var_epsilon}-Co(hcp) phases depart from the standard sequence (hcp {yields} bcc{yields} hcp {yields} fcc), as observed in all other non-magnetic transition metals with increasing the d-band occupancy, and are different from those of their 4d- and 5d-counter parts. This anomalous behavior has been interpreted in terms of the spin-polarized d-band altering the d-band occupancy [1]. At high pressures, however, the d-valence band is expected to broaden resulting in a suppression or even a complete loss of magnetism. Experimentally, ferromagnetic {alpha}(bcc)-Fe has been confirmed to transform to non-magnetic {var_epsilon}-Fe (hcp) at 10 GPa [2,3]. Recently, we have also observed a similar transition in Co from ferromagnetic {alpha}(hcp)-Co to likely nonmagnetic {beta}(fcc)-Co at 105 GPa[4]. A similar structural phase transition is expected in Ni, probably in the second-order fcc-fcc transition. However, there has been no directly measured change in magnetism associated with the structural phase transition in Co, nor has yet been confirmed such an iso-structural phase transition in Ni. Similar electronic transitions have been proposed in these 3d-transition metal oxides (FeO, CoO and NiO) from high spin (magnetic) to low spin (nonmagnetic) states [5]. In each of these systems, the magnetic transition is accompanied by a first-order structural transition involving large volume collapse (10% in FeO, for example). So far, there have been no electronic measurements under pressure confirming these significant theoretical predictions, although the predicted pressures for the volume collapse transitions are within the experimental pressure range (80-200GPa).« less

  3. Simulation of the 3-D Evolution of Electron Scale Magnetic Reconnection - Motivated by Laboratory Experiments Predictions for MMS

    NASA Astrophysics Data System (ADS)

    Buechner, J.; Jain, N.; Sharma, A.

    2013-12-01

    The four s/c of the Magnetospheric Multiscale (MMS) mission, to be launched in 2014, will use the Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes. One of them is magnetic reconnection, an essentially multi-scale process. While laboratory experiments and past theoretical investigations have shown that important processes necessary to understand magnetic reconnection take place at electron scales the MMS mission for the first time will be able to resolve these scales by in space observations. For the measurement strategy of MMS it is important to make specific predictions of the behavior of current sheets with a thickness of the order of the electron skin depth which play an important role in the evolution of collisionless magnetic reconnection. Since these processes are highly nonlinear and non-local numerical simulation is needed to specify the current sheet evolution. Here we present new results about the nonlinear evolution of electron-scale current sheets starting from the linear stage and using 3-D electron-magnetohydrodynamic (EMHD) simulations. The growth rates of the simulated instabilities compared well with the growth rates obtained from linear theory. Mechanisms and conditions of the formation of flux ropes and of current filamentation will be discussed in comparison with the results of fully kinetic simulations. In 3D the X- and O-point configurations of the magnetic field formed in reconnection planes alternate along the out-of-reconnection-plane direction with the wavelength of the unstable mode. In the presence of multiple reconnection sites, the out-of-plane magnetic field can develop nested structure of quadrupoles in reconnection planes, similar to the 2-D case, but now with variations in the out-of-plane direction. The structures of the electron flow and magnetic field in 3-D simulations will be compared with those in 2-D simulations to discriminate the essentially 3D features. We also discuss the influence of guide fields, as in the magnetopause case and show how the 3-D evolution of an electron current sheet is influenced the strength of the guide field. This is unlike the 2-D case where reconnection takes place only in a plane. This work was partially funded by the Max-Planck/Princeton Center for Plasma Physics and the National Science Foundation.

  4. Fragility of ferromagnetic double exchange interactions and pressure tuning of magnetism in 3d–5d double perovskite Sr₂FeOsO₆

    DOE PAGES

    Veiga, L. S. I.; Fabbris, G.; van Veenendaal, M.; ...

    2015-06-19

    The ability to tune exchange (magnetic) interactions between 3d transition metals in perovskite structures has proven to be a powerful route to discovery of novel properties. Here we demonstrate that the introduction of 3d-5d exchange pathways in double perovskites enables additional tunability, a result of the large spatial extent of 5d wave functions. Using x-ray probes of magnetism and structure at high pressure, we show that compression of Sr₂FeOsO₆ drives an unexpected continuous change in the sign of Fe-Os exchange interactions and a transition from antiferromagnetic to ferrimagnetic order. We analyze the relevant electron-electron interactions, shedding light into fundamental differencesmore » with the more thoroughly studied 3d-3d systems.« less

  5. Total reaction cross sections of electronic state-specified transition metal cations: V + +C2H6, C3H8, and C2H4 at 0.2 eV

    NASA Astrophysics Data System (ADS)

    Sanders, Lary; Hanton, Scott D.; Weisshaar, James C.

    1990-03-01

    We describe a crossed beam experiment which measures total cross sections for reaction of electronic state-specified V+ with small hydrocarbons at well-defined collision energy E=0.2 eV. The V+ state distribution created at each ionizing wavelength is directly measured by angle-integrated photoelectron spectroscopy (preceding paper). Reactant and product ions are collected and analyzed by pulsed time-of-flight mass spectrometry following a reaction time of 6 μs. Tests of the performance of the apparatus are described in detail. Our experiment defines the reactant V+ electronic state distribution and the collision energy much more precisely than previous work. For all three hydrocarbons C2H6, C3H8, and C2H4, H2 elimination products dominate at 0.2 eV. We observe a dramatic dependence of cross section on the V+ electronic term. The second excited term 3d34s(3F) is more reactive than either lower energy quintet term 3d4(5D) or 3d34s(5F) by a factor of ≥270, 80, and ≥6 for the C2H6, C3H8, and C2H4 reactions, respectively. The 3d34s(3F) reaction cross sections at 0.2 eV are 20±11 Å2, 37±19 Å2, and 2.7±1.6 Å2, respectively, compared with Langevin cross sections of ˜80 Å2. For the C2H6 and C3H8 reactions, cross sections are independent of initial spin-orbit level J within the 3F term to the limits of our accuracy. Comparison with earlier work by Armentrout and co-workers shows that electronic excitation to d3s(3F) is far more effective at promoting H2 elimination than addition of the same total kinetic energy to reactants. Electron spin is clearly a key determinant of V+ reactivity with small hydrocarbons. We suggest that triplet V+ reacts much more efficiently than quintet V+ because of its ability to conserve total electron spin along paths to insertion in a C-H bond of the hydrocarbon.

  6. Nitrogen-doped 3D reduced graphene oxide/polyaniline composite as active material for supercapacitor electrodes

    NASA Astrophysics Data System (ADS)

    Liu, Zhisen; Li, Dehao; Li, Zesheng; Liu, Zhenghui; Zhang, Zhiyuan

    2017-11-01

    A facile strategy for the fabrication of a nitrogen-doped 3D reduced graphene oxide (N-3D-rGO) macroporous structure is proposed in this paper. The proposed strategy used polystyrene microspheres as the templates and melamine as the nitrogen source. Using β-MnO2 as the oxidant, the as-prepared N-3D-rGO was then composited with polyaniline (PANI) nanowires (denoted as N-3D-rGO/PANI-B). The structure, morphology, and electrochemical properties of the composites were characterized by X-ray diffraction, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, Brunauer-Emmett-Teller analysis, scanning electron microscopy, transmission electron microscopy, cyclic voltammetry, charge-discharge test, and electrochemical impedance spectroscopy. Results revealed that the N-3D-rGO/PANI-B composite has a better specific capacity than the composites prepared with 3D-rGO as the support material and peroxydisulfate as the oxidant. These results suggested that N-3D-rGO/PANI-B has potential applications in supercapacitors.

  7. Electronic structure of the chiral helimagnet and 3d-intercalated transition metal dichalcogenide Cr 1/3NbS 2

    DOE PAGES

    Sirca, N.; Mo, S. -K.; Bondino, F.; ...

    2016-08-18

    The electronic structure of the chiral helimagnet Cr 1/3NbS 2 has been studied with core level and angle-resolved photoemission spectroscopy (ARPES). Intercalated Cr atoms are found to be effective in donating electrons to the NbS 2 layers but also cause significant modifications of the electronic structure of the host NbS 2 material. Specifically, the data provide evidence that a description of the electronic structure of Cr 1/3NbS 2 on the basis of a simple rigid band picture is untenable. The data also reveal substantial inconsistencies with the predictions of standard density functional theory. In conclusion, the relevance of these resultsmore » to the attainment of a correct description of the electronic structure of chiral helimagnets, magnetic thin films/multilayers, and transition metal dichalcogenides intercalated with 3d magnetic elements is discussed.« less

  8. Compare Vehicle Technologies | Transportation Research | NREL

    Science.gov Websites

    electric car diagramming energy storage, power electronics, and climate control components, as well as storage, power electronics, and climate control components, as well as energy flow among components. 3-D control components, as well as energy flow among components. 3-D illustration of electric car diagramming

  9. Cryo-electron microscopy and cryo-electron tomography of nanoparticles.

    PubMed

    Stewart, Phoebe L

    2017-03-01

    Cryo-transmission electron microscopy (cryo-TEM or cryo-EM) and cryo-electron tomography (cryo-ET) offer robust and powerful ways to visualize nanoparticles. These techniques involve imaging of the sample in a frozen-hydrated state, allowing visualization of nanoparticles essentially as they exist in solution. Cryo-TEM grid preparation can be performed with the sample in aqueous solvents or in various organic and ionic solvents. Two-dimensional (2D) cryo-TEM provides a direct way to visualize the polydispersity within a nanoparticle preparation. Fourier transforms of cryo-TEM images can confirm the structural periodicity within a sample. While measurement of specimen parameters can be performed with 2D TEM images, determination of a three-dimensional (3D) structure often facilitates more spatially accurate quantization. 3D structures can be determined in one of two ways. If the nanoparticle has a homogeneous structure, then 2D projection images of different particles can be averaged using a computational process referred to as single particle reconstruction. Alternatively, if the nanoparticle has a heterogeneous structure, then a structure can be generated by cryo-ET. This involves collecting a tilt-series of 2D projection images for a defined region of the grid, which can be used to generate a 3D tomogram. Occasionally it is advantageous to calculate both a single particle reconstruction, to reveal the regular portions of a nanoparticle structure, and a cryo-electron tomogram, to reveal the irregular features. A sampling of 2D cryo-TEM images and 3D structures are presented for protein based, DNA based, lipid based, and polymer based nanoparticles. WIREs Nanomed Nanobiotechnol 2017, 9:e1417. doi: 10.1002/wnan.1417 For further resources related to this article, please visit the WIREs website. © 2016 Wiley Periodicals, Inc.

  10. Magnetism in curved geometries

    NASA Astrophysics Data System (ADS)

    Streubel, Robert

    Deterministically bending and twisting two-dimensional structures in the three-dimensional (3D) space provide means to modify conventional or to launch novel functionalities by tailoring curvature and 3D shape. The recent developments of 3D curved magnetic geometries, ranging from theoretical predictions over fabrication to characterization using integral means as well as advanced magnetic tomography, will be reviewed. Theoretical works predict a curvature-induced effective anisotropy and effective Dzyaloshinskii-Moriya interaction resulting in a vast of novel effects including magnetochiral effects (chirality symmetry breaking) and topologically induced magnetization patterning. The remarkable development of nanotechnology, e.g. preparation of high-quality extended thin films, nanowires and frameworks via chemical and physical deposition as well as 3D nano printing, has granted first insights into the fundamental properties of 3D shaped magnetic objects. Optimizing magnetic and structural properties of these novel 3D architectures demands new investigation methods, particularly those based on vector tomographic imaging. Magnetic neutron tomography and electron-based 3D imaging, such as electron holography and vector field electron tomography, are well-established techniques to investigate macroscopic and nanoscopic samples, respectively. At the mesoscale, the curved objects can be investigated using the novel method of magnetic X-ray tomography. In spite of experimental challenges to address the appealing theoretical predictions of curvature-induced effects, those 3D magnetic architectures have already proven their application potential for life sciences, targeted delivery, realization of 3D spin-wave filters, and magneto-encephalography devices, to name just a few. DOE BES MSED (DE-AC02-05-CH11231).

  11. Atomic electron tomography: 3D structures without crystals

    DOE PAGES

    Miao, Jianwei; Ercius, Peter; Billinge, S. J. L.

    2016-09-23

    Crystallography has been fundamental to the development of many fields of science over the last century. However, much of our modern science and technology relies on materials with defects and disorders, and their three-dimensional (3D) atomic structures are not accessible to crystallography. One method capable of addressing this major challenge is atomic electron tomography. By combining advanced electron microscopes and detectors with powerful data analysis and tomographic reconstruction algorithms, it is now possible to determine the 3D atomic structure of crystal defects such as grain boundaries, stacking faults, dislocations, and point defects, as well as to precisely localize the 3Dmore » coordinates of individual atoms in materials without assuming crystallinity. In this work, we review the recent advances and the interdisciplinary science enabled by this methodology. We also outline further research needed for atomic electron tomography to address long-standing unresolved problems in the physical sciences.« less

  12. Rational evaluation of the therapeutic effect and dosimetry of auger electrons for radionuclide therapy in a cell culture model.

    PubMed

    Shinohara, Ayaka; Hanaoka, Hirofumi; Sakashita, Tetsuya; Sato, Tatsuhiko; Yamaguchi, Aiko; Ishioka, Noriko S; Tsushima, Yoshito

    2018-02-01

    Radionuclide therapy with low-energy auger electron emitters may provide high antitumor efficacy while keeping the toxicity to normal organs low. Here we evaluated the usefulness of an auger electron emitter and compared it with that of a beta emitter for tumor treatment in in vitro models and conducted a dosimetry simulation using radioiodine-labeled metaiodobenzylguanidine (MIBG) as a model compound. We evaluated the cellular uptake of 125 I-MIBG and the therapeutic effects of 125 I- and 131 I-MIBG in 2D and 3D PC-12 cell culture models. We used a Monte Carlo simulation code (PHITS) to calculate the absorbed radiation dose of 125 I or 131 I in computer simulation models for 2D and 3D cell cultures. In the dosimetry calculation for the 3D model, several distribution patterns of radionuclide were applied. A higher cumulative dose was observed in the 3D model due to the prolonged retention of MIBG compared to the 2D model. However, 125 I-MIBG showed a greater therapeutic effect in the 2D model compared to the 3D model (respective EC 50 values in the 2D and 3D models: 86.9 and 303.9 MBq/cell), whereas 131 I-MIBG showed the opposite result (respective EC 50 values in the 2D and 3D models: 49.4 and 30.2 MBq/cell). The therapeutic effect of 125 I-MIBG was lower than that of 131 I-MIBG in both models, but the radionuclide-derived difference was smaller in the 2D model. The dosimetry simulation with PHITS revealed the influence of the radiation quality, the crossfire effect, radionuclide distribution, and tumor shape on the absorbed dose. Application of the heterogeneous distribution series dramatically changed the radiation dose distribution of 125 I-MIBG, and mitigated the difference between the estimated and measured therapeutic effects of 125 I-MIBG. The therapeutic effect of 125 I-MIBG was comparable to that of 131 I-MIBG in the 2D model, but the efficacy was inferior to that of 131 I-MIBG in the 3D model, since the crossfire effect is negligible and the homogeneous distribution of radionuclides was insufficient. Thus, auger electrons would be suitable for treating small-sized tumors. The design of radiopharmaceuticals with auger electron emitters requires particularly careful consideration of achieving a homogeneous distribution of the compound in the tumor.

  13. Serial block-face scanning electron microscopy applied to study the trafficking of 8D3-coated gold nanoparticles at the blood-brain barrier.

    PubMed

    Cabezón, Itsaso; Augé, Elisabet; Bosch, Manel; Beckett, Alison J; Prior, Ian A; Pelegrí, Carme; Vilaplana, Jordi

    2017-07-01

    Due to the physical and physiological properties of the blood-brain barrier (BBB), the transport of neurotherapeutics from blood to brain is still a pharmaceutical challenge. We previously conducted a series of experiments to explore the potential of the anti-transferrin receptor 8D3 monoclonal antibody (mAb) to transport neurotherapeutics across the BBB. In that study, gold nanoparticles (AuNPs) were coated with the 8D3 antibody and administered intravenously to mice. Transmission electron microscopy was used and a two-dimensional (2D) image analysis was performed to detect the AuNPs in the brain capillary endothelial cells (BCECs) and brain parenchyma. In the present work, we determined that serial block-face scanning electron microscopy (SBF-SEM) is a useful tool to study the transcytosis of these AuNPs across the BBB in three dimensions and we, therefore, applied it to gain more knowledge of their transcellular trafficking. The resulting 3D reconstructions provided additional information on the endocytic vesicles containing AuNPs and the endosomal processing that occurs inside BCECs. The passage from 2D to 3D analysis reinforced the trafficking model proposed in the 2D study, and revealed that the vesicles containing AuNPs are significantly larger and more complex than described in our 2D study. We also discuss tradeoffs of using this technique for our application, and conclude that together with other volume electron microscopy imaging techniques, SBF-SEM is a powerful approach that is worth of considering for studies of drug transport across the BBB.

  14. Single-dose lubiprostone along with split-dose PEG solution without dietary restrictions for bowel cleansing prior to colonoscopy: a randomized, double-blind, placebo-controlled trial.

    PubMed

    Stengel, Joel Z; Jones, David P

    2008-09-01

    Proper colonic cleansing prior to colonoscopy is paramount to ensuring complete mucosal visualization and polyp identification. In a double-blind fashion, we compared single-dose lubiprostone (24 microg) versus placebo pretreatment prior to a split-dose polyethylene glycol electrolyte (PEG-E) bowel preparation without dietary restriction to determine the efficacy, safety, and patient tolerability. Two hundred patients referred for outpatient colorectal cancer screening were randomized to receive a single-dose of unlabeled lubiprostone (24 microg) or placebo prior to a split-dose PEG-E bowel preparation without dietary restriction. The patients were surveyed prior to the colonoscopy on the tolerability of the bowel preparation, and any adverse events were recorded. The cleanliness of the colon was graded by the endoscopist during the procedure utilizing the Ottawa bowel preparation scale. One hundred ninety-one patients completed the study (95%). Split-dose PEG-E with lubiprostone pretreatment was found to be more effective at bowel cleansing in each segment of the colon when compared with split-dose PEG-E with placebo (P < 0.001). Patients enrolled in the lubiprostone treatment arm rated the overall experience as more tolerable (P 0.003) and complained of less abdominal bloating (P 0.049). No differences were observed between the groups for treatment-emergent side effects or adverse events (P > 0.05). Single-dose lubiprostone prior to split-dose PEG-E without dietary restriction significantly improves colonic mucosa visualization during colonoscopy and is well tolerated by patients.

  15. RAPA: a novel in vitro method to evaluate anti-bacterial skin cleansing products.

    PubMed

    Ansari, S A; Gafur, R B; Jones, K; Espada, L A; Polefka, T G

    2010-04-01

    Development of efficacious anti-bacterial skin cleansing products has been limited by the availability of a pre-clinical (in vitro) method to predict clinical efficacy adequately. We report a simple and rapid method, designated as rapid agar plate assay (RAPA), that uses the bacteriological agar surface as a surrogate substrate for skin and combines elements of two widely used in vivo (clinical) methods (Agar Patch and Cup Scrub). To simulate the washing of the human hand or forearm skin with the test product, trypticase soy agar plates were directly washed with the test product and rinsed under running tap water. After air-drying the washed plates, test bacteria (Staphylococcus aureus or Escherichia coli) were applied and the plates were incubated at 37 degrees C for 18-24 h. Using S. aureus as the test organism, anti-bacterial bar soap containing triclocarbanilide showed a strong linear relationship (R(2) = 0.97) between bacterial dose and their per cent reduction. A similar dose-response relationship (R(2) = 0.96) was observed for anti-bacterial liquid hand soap against E. coli. RAPA was able to distinguish between anti-bacterial products based on the nature and level of actives in them. In limited comparative tests, results obtained by RAPA were comparable with the results obtained by clinical agar patch and clinical cup scrub methods. In conclusion, RAPA provides a simple, rugged and reproducible in vitro method for testing the relative efficacy of anti-bacterial skin cleansing products with a likelihood of comparable clinical efficacy. Further testing is warranted to improve the clinical predictability of this method.

  16. Comparison of the Efficacy and Safety of Sodium Phosphate Tablets and Polyethylene Glycol Solution for Bowel Cleansing in Healthy Korean Adults

    PubMed Central

    Lee, Seung-Hwa; Kim, Kwang-Min; Seo, Sang-Wook; Kang, Joon-Koo; Lee, Eun-Hye; Lee, Dong-Ryul

    2014-01-01

    Purpose Bowel cleansing is generally regarded as time-consuming and unpleasant among patients. Patients commonly state that bowel preparation provokes more discomfort than the actual colonoscopic examination. The purpose of this study was to compare two regimens of sodium phosphate (NaP) tablets versus polyethylene glycol (PEG) solution for bowel preparation in healthy Korean adults. Materials and Methods This was a single center, prospective, open-label, investigator-blinded, randomized, controlled-pilot study. A total of 62 healthy Korean subjects were randomly assigned to two groups (NaP vs. PEG). Efficacy, safety, and patient-related outcomes, as well as procedural parameters, were evaluated. Results Although there were no significant differences in total Ottawa bowel quality score, fluid scores and the rate of adequate bowel preparation were significantly better in the NaP group than the PEG group. Additionally, the NaP group showed better results regarding patient tolerance, satisfaction, preference, and rate of adverse events than the PEG group. Significant fluctuations in specific serum electrolytes were common and of a greater magnitude in the NaP group than the PEG group. However, these abnormalities were transient and did not result in serious complications and side effects. Conclusion In this study, NaP tablets were shown to be an effective, well-tolerated, and acceptable regimen for bowel preparation. Also, our study suggests that NaP tablets may be safe and can be used as a bowel cleansing agent in healthy adults undergoing elective colonoscopy. Further multicenter, large scale studies are needed to confirm these findings. PMID:25323890

  17. Novel 3D metallic boron nitride containing only sp2 bonds

    NASA Astrophysics Data System (ADS)

    Wang, Hao; Zhang, Wei; Huai, Ping

    2017-09-01

    As the closest isoelectronic analogue of carbon, boron nitride (BN) shares a similar structure with carbon from 1D nanotubes, 2D nanosheets, and 3D diamond structures. However, most BN structures are insulators, which limits their application. In this work, under the inspiration of the sp2 hybridized carbon honeycomb, we propose a hexagonal phase of BN consisting of only sp2 bonds, which exhibits intriguingly intrinsic metallicity. First-principles calculations confirm that this phase is both thermally and dynamically stable. Moreover, the calculations on the band structure, partial density states and electron localization function suggest that the metallic behavior is attributable to the delocalized B-2p electrons, leading to second-neighbor interaction between the p z states of sp2-bonded B atoms in adjacent layers. Our findings not only enrich the BN allotrope family with 3D structures but also stimulate further experimental interest in applications of metallic BN in electronic devices.

  18. A desktop 3D printer with dual extruders to produce customised electronic circuitry

    NASA Astrophysics Data System (ADS)

    Butt, Javaid; Onimowo, Dominic Adaoiza; Gohrabian, Mohammed; Sharma, Tinku; Shirvani, Hassan

    2018-03-01

    3D printing has opened new horizons for the manufacturing industry in general, and 3D printers have become the tools for technological advancements. There is a huge divide between the pricing of industrial and desktop 3D printers with the former being on the expensive side capable of producing excellent quality products and latter being on the low-cost side with moderate quality results. However, there is a larger room for improvements and enhancements for the desktop systems as compared to the industrial ones. In this paper, a desktop 3D printer called Prusa Mendel i2 has been modified and integrated with an additional extruder so that the system can work with dual extruders and produce bespoke electronic circuits. The communication between the two extruders has been established by making use of the In-Chip Serial Programming port on the Arduino Uno controlling the printer. The biggest challenge is to control the flow of electric paint (to be dispensed by the new extruder) and CFD (Computational Fluid Dynamics) analysis has been carried out to ascertain the optimal conditions for proper dispensing. The final product is a customised electronic circuit with the base of plastic (from the 3D printer's extruder) and electronic paint (from the additional extruder) properly dispensed to create a live circuit on a plastic platform. This low-cost enhancement to a desktop 3D printer can provide a new prospect to produce multiple material parts where the additional extruder can be filled with any material that can be properly dispensed from its nozzle.

  19. Unexpected storm-time nightside plasmaspheric density enhancement at low L shell

    NASA Astrophysics Data System (ADS)

    Chu, X.; Bortnik, J.; Denton, R. E.; Yue, C.

    2017-12-01

    We have developed a three-dimensional dynamic electron density (DEN3D) model in the inner magnetosphere using a neural network approach. The DEN3D model can provide spatiotemporal distribution of the electron density at any location and time that spacecraft observations are not available. Given DEN3D's good performance in predicting the structure and dynamic evolution of the plasma density, the salient features of the DEN3D model can be used to gain further insight into the physics. For instance, the DEN3D models can be used to find unusual phenomena that are difficult to detect in observations or simulations. We report, for the first time, an unexpected plasmaspheric density increase at low L shell regions on the nightside during the main phase of a moderate storm during 12-16 October 2004, as opposed to the expected density decrease due to storm-time plasmaspheric erosion. The unexpected density increase is first discovered in the modeled electron density distribution using the DEN3D model, and then validated using in-situ density measurements obtained from the IMAGE satellite. The density increase was likely caused by increased earthward transverse field plasma transport due to enhanced nightside ExB drift, which coincided with enhanced solar wind electric field and substorm activity. This is consistent with the results of physics-based simulation SAMI3 model which show earthward enhanced plasma transport and electron density increase at low L shells during storm main phase.

  20. 3D structural fluctuation of IgG1 antibody revealed by individual particle electron tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xing; Zhang, Lei; Tong, Huimin

    2015-05-05

    Commonly used methods for determining protein structure, including X-ray crystallography and single-particle reconstruction, often provide a single and unique three-dimensional (3D) structure. However, in these methods, the protein dynamics and flexibility/fluctuation remain mostly unknown. Here, we utilized advances in electron tomography (ET) to study the antibody flexibility and fluctuation through structural determination of individual antibody particles rather than averaging multiple antibody particles together. Through individual-particle electron tomography (IPET) 3D reconstruction from negatively-stained ET images, we obtained 120 ab-initio 3D density maps at an intermediate resolution (~1–3 nm) from 120 individual IgG1 antibody particles. Using these maps as a constraint, wemore » derived 120 conformations of the antibody via structural flexible docking of the crystal structure to these maps by targeted molecular dynamics simulations. Statistical analysis of the various conformations disclosed the antibody 3D conformational flexibility through the distribution of its domain distances and orientations. This blueprint approach, if extended to other flexible proteins, may serve as a useful methodology towards understanding protein dynamics and functions.« less

  1. Protein 3D Structure and Electron Microscopy Map Retrieval Using 3D-SURFER2.0 and EM-SURFER.

    PubMed

    Han, Xusi; Wei, Qing; Kihara, Daisuke

    2017-12-08

    With the rapid growth in the number of solved protein structures stored in the Protein Data Bank (PDB) and the Electron Microscopy Data Bank (EMDB), it is essential to develop tools to perform real-time structure similarity searches against the entire structure database. Since conventional structure alignment methods need to sample different orientations of proteins in the three-dimensional space, they are time consuming and unsuitable for rapid, real-time database searches. To this end, we have developed 3D-SURFER and EM-SURFER, which utilize 3D Zernike descriptors (3DZD) to conduct high-throughput protein structure comparison, visualization, and analysis. Taking an atomic structure or an electron microscopy map of a protein or a protein complex as input, the 3DZD of a query protein is computed and compared with the 3DZD of all other proteins in PDB or EMDB. In addition, local geometrical characteristics of a query protein can be analyzed using VisGrid and LIGSITE CSC in 3D-SURFER. This article describes how to use 3D-SURFER and EM-SURFER to carry out protein surface shape similarity searches, local geometric feature analysis, and interpretation of the search results. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  2. Electron scattering by laser-excited barium atoms

    NASA Technical Reports Server (NTRS)

    Register, D. F.; Trajmar, S.; Jensen, S. W.; Poe, R. T.

    1978-01-01

    Inelastic and superelastic scattering of 30- and 100-eV electrons by laser-excited 6s 6p 1P and subsequent cascade-populated 6s 6p 3P, 6s 5d 1D, and 6s 5d 3D Ba atoms have been observed. Absolute differential cross sections for the singlet and relative scattering intensities for the triplet species have been determined in the 5 to 20 deg angular region. Under the present conditions excitations dominate over deexcitations.

  3. Electron-correlation effects on the 3 C to 3 D line-intensity ratio in the Ne-like ions Ar 8 + to Kr 26 +

    DOE PAGES

    Santana, Juan A.; Lepson, Jaan K.; Trabert, Elmar; ...

    2015-01-07

    We present a theoretical and experimental investigation of the 3d→2p resonance to the intercombination line ratio in low- to mid-Z neonlike ions of astrophysical interest, i.e., of the 2p 1/22p 4 3/23d 3/2 1P o 1 → 2p 6 1S 0 and 2p 2 1/22p 3 3/23d 5/2 3D o 1 → 2p 6 1S 0 transitions commonly labeled 3C and 3D, respectively. In particular, we have employed the configuration-interaction method with three different numbers of basis states and the many-body perturbation theory method to calculate oscillator strengths and energies for neonlike ions from Z = 18 to 36. Combiningmore » our calculations with a systematic study of previous works in the literature, we show that these methods can predict accurate and converged energies for these transitions. We also find convergence for the oscillator strengths, but the ratio of oscillator strengths, which can be compared to experimental values of the relative intensity ratios of these lines, appears to converge to values higher than measured. We speculate that this is due to the role of electron-electron correlations. While the amount of electron correlations associated with the intercombination line 3D appears to be well described, it seems that the contributions from highly excited states are not sufficiently accounted for in the case of the resonance line 3C. In order to augment the body of available experimental data for neonlike ions, we present a measurement of the 3C and 3D lines in neonlike Ar 8+. We report a wavelength of 41.480±0.001 Å for line 3C and 42.005±0.001 Å for line 3D. Lastly, the intensity ratio of the two lines was determined to be I(3C)/I(3D)=11.32±1.40.« less

  4. MANAGEMENT OF HOUSEHOLD AND SMALL-QUANTITY-GENERATOR HAZARDOUS WASTE IN THE UNITED STATES

    EPA Science Inventory

    The International Solid Waste and Public Cleansing Association (ISWA), an international nongovernmental organization comprising twenty-seven national organizations of waste management professionals, conducted a survey to obtain information regarding household and small-quantity-g...

  5. An Integrated Experimental and Computational Study of Heating due to Surface Catalysis under Hypersonic Conditions

    DTIC Science & Technology

    2012-08-01

    17 1.1.1 Mass production / destruction terms . . . . . . . . . . . . . . . . . . . . 18 1.1.2 Energy exchange terms...that US3D does not cur- rently model electronic energy . If the US3D solution is post-processed to account for electronic energy modes, the computed...nonequilibrium model for electronic energy to the 12 Distribution A: Approved for public release; distribution is unlimited. Figure 9: (left) jet profile solution

  6. Magnetic and electronic properties of La3 MO7 and possible polaron formation in hole-doped La3 MO7 (M  =  Ru and Os)

    NASA Astrophysics Data System (ADS)

    Gao, Bin; Weng, Yakui; Zhang, Jun-Jie; Zhang, Huimin; Zhang, Yang; Dong, Shuai

    2017-03-01

    Oxides with 4d/5d transition metal ions are physically interesting for their particular crystalline structures as well as the spin-orbit coupled electronic structures. Recent experiments revealed a series of 4d/5d transition metal oxides R 3 MO7 (R: rare earth; M: 4d/5d transition metal) with unique quasi-one-dimensional M chains. Here first-principles calculations have been performed to study the electronic structures of La3OsO7 and La3RuO7. Our study confirm both of them to be Mott insulating antiferromagnets with identical magnetic order. The reduced magnetic moments, which are much smaller than the expected value for ideal high-spin state (3 t 2g orbitals occupied), are attributed to the strong p  -  d hybridization with oxygen ions, instead of the spin-orbit coupling. The Ca-doping to La3OsO7 and La3RuO7 can not only modulate the nominal carrier density but also affect the orbital order as well as the local distortions. The Coulombic attraction and particular orbital order would prefer to form polarons, which might explain the puzzling insulating behavior of doped 5d transition metal oxides. In addition, our calculations predict that the Ca-doping can trigger ferromagnetism in La3RuO7 but not in La3OsO7.

  7. Achieving the best bowel preparation for colonoscopy

    PubMed Central

    Parra-Blanco, Adolfo; Ruiz, Alex; Alvarez-Lobos, Manuel; Amorós, Ana; Gana, Juan Cristóbal; Ibáñez, Patricio; Ono, Akiko; Fujii, Takahiro

    2014-01-01

    Bowel preparation is a core issue in colonoscopy, as it is closely related to the quality of the procedure. Patients often find that bowel preparation is the most unpleasant part of the examination. It is widely accepted that the quality of cleansing must be excellent to facilitate detecting neoplastic lesions. In spite of its importance and potential implications, until recently, bowel preparation has not been the subject of much study. The most commonly used agents are high-volume polyethylene glycol (PEG) electrolyte solution and sodium phosphate. There has been some confusion, even in published meta-analyses, regarding which of the two agents provides better cleansing. It is clear now that both PEG and sodium phosphate are effective when administered with proper timing. Consequently, the timing of administration is recognized as one of the central factors to the quality of cleansing. The bowel preparation agent should be administered, at least in part, a few hours in advance of the colonoscopy. Several low volume agents are available, and either new or modified schedules with PEG that usually improve tolerance. Certain adjuvants can also be used to reduce the volume of PEG, or to improve the efficacy of other agents. Other factors apart from the choice of agent can improve the quality of bowel cleansing. For instance, the effect of diet before colonoscopy has not been completely clarified, but an exclusively liquid diet is probably not required, and a low-fiber diet may be preferable because it improves patient satisfaction and the quality of the procedure. Some patients, such as diabetics and persons with heart or kidney disease, require modified procedures and certain precautions. Bowel preparation for pediatric patients is also reviewed here. In such cases, PEG remains the most commonly used agent. As detecting neoplasia is not the main objective with these patients, less intensive preparation may suffice. Special considerations must be made for patients with inflammatory bowel disease, including safety and diagnostic issues, so that the most adequate agent is chosen. Identifying neoplasia is one of the main objectives of colonoscopy with these patients, and the target lesions are often almost invisible with white light endoscopy. Therefore excellent quality preparation is required to find these lesions and to apply advanced methods such as chromoendoscopy. Bowel preparation for patients with lower gastrointestinal bleeding represents a challenge, and the strategies available are also reviewed here. PMID:25548470

  8. Atomic-Scale Origin of the Quasi-One-Dimensional Metallic Conductivity in Strontium Niobates with Perovskite-Related Layered Structures.

    PubMed

    Chen, Chunlin; Yin, Deqiang; Inoue, Kazutoshi; Lichtenberg, Frank; Ma, Xiuliang; Ikuhara, Yuichi; Bednorz, Johannes Georg

    2017-12-26

    The quasi-one-dimensional (1D) metallic conductivity of the perovskite-related Sr n Nb n O 3n+2 compounds is of continuing fundamental physical interest as well as being important for developing advanced electronic devices. The Sr n Nb n O 3n+2 compounds can be derived by introducing additional oxygen into the SrNbO 3 perovskite. However, the physical origin for the transition of electrical properties from the three-dimensional (3D) isotropic conductivity in SrNbO 3 to the quasi-1D metallic conductivity in Sr n Nb n O 3n+2 requires more in-depth clarification. Here we combine advanced transmission electron microscopy with atomistic first-principles calculations to unambiguously determine the atomic and electronic structures of the Sr n Nb n O 3n+2 compounds and reveal the underlying mechanism for their quasi-1D metallic conductivity. We demonstrate that the local electrical conductivity in the Sr n Nb n O 3n+2 compounds directly depends on the configuration of the NbO 6 octahedra in local regions. These findings will shed light on the realization of two-dimensional (2D) electrical conductivity from a bulk material, namely by segmenting a 3D conductor into a stack of 2D conducting thin layers.

  9. Electronically highly cubic conditions for Ru in α -RuCl3

    NASA Astrophysics Data System (ADS)

    Agrestini, S.; Kuo, C.-Y.; Ko, K.-T.; Hu, Z.; Kasinathan, D.; Vasili, H. B.; Herrero-Martin, J.; Valvidares, S. M.; Pellegrin, E.; Jang, L.-Y.; Henschel, A.; Schmidt, M.; Tanaka, A.; Tjeng, L. H.

    2017-10-01

    We studied the local Ru 4 d electronic structure of α -RuCl3 by means of polarization-dependent x-ray absorption spectroscopy at the Ru L2 ,3 edges. We observed a vanishingly small linear dichroism indicating that electronically the Ru 4 d local symmetry is highly cubic. Using full multiplet cluster calculations we were able to reproduce the spectra excellently and to extract that the trigonal splitting of the t2 g orbitals is -12 ±10 meV, i.e., negligible as compared to the Ru 4 d spin-orbit coupling constant. Consistent with our magnetic circular dichroism measurements, we found that the ratio of the orbital and spin moments is 2.0, the value expected for a Jeff=1/2 ground state. We have thus shown that as far as the Ru 4 d local properties are concerned, α -RuCl3 is an ideal candidate for the realization of Kitaev physics.

  10. Laser ablated copper plasmas in liquid and gas ambient

    NASA Astrophysics Data System (ADS)

    Kumar, Bhupesh; Thareja, Raj K.

    2013-05-01

    The dynamics of copper ablated plasma plumes generated using laser ablation of copper targets in both liquid (de-ionized water) and gas (air) ambients is reported. Using time and space resolved visible emission spectroscopy (450-650 nm), the plasma plumes parameters are investigated. The electron density (ne) determined using Stark broadening of the Cu I (3d104d1 2D3/2-3d104p1 2P3/2 at 521.8 nm) line is estimated and compared for both plasma plumes. The electron temperature (Te) was estimated using the relative line emission intensities of the neutral copper transitions. Field emission scanning electron microscopy and energy dispersive x-ray spectral analysis of the ablated copper surface indicated abundance of spherical nanoparticles in liquid while those in air are amalgamates of irregular shapes. The nanoparticles suspended in the confining liquid form aggregates and exhibit a surface plasmon resonance at ˜590 nm.

  11. The improved electrochemical performance of cross-linked 3D graphene nanoribbon monolith electrodes

    NASA Astrophysics Data System (ADS)

    Vineesh, Thazhe Veettil; Alwarappan, Subbiah; Narayanan, Tharangattu N.

    2015-04-01

    Technical advancement in the field of ultra-small sensors and devices demands the development of novel micro- or nano-based architectures. Here we report the design and assembly of cross-linked three dimensional graphene nanoribbons (3D GNRs) using solution based covalent binding of individual 2D GNRs and demonstrate its electrochemical application as a 3D electrode. The enhanced performance of 3D GNRs over individual 2D GNRs is established using standard redox probes - [Ru(NH3)6]3+/2+, [Fe(CN)6]3-/4- and important bio-analytes - dopamine and ascorbic acid. 3D GNRs are found to have high double layer capacitance (2482 μF cm-2) and faster electron transfer kinetics; their exceptional electrocatalytic activity towards the oxygen reduction reaction is indicative of their potential over a wide range of electrochemical applications. Moreover, this study opens a new platform for the design of novel point-of-care devices and electrodes for energy devices.Technical advancement in the field of ultra-small sensors and devices demands the development of novel micro- or nano-based architectures. Here we report the design and assembly of cross-linked three dimensional graphene nanoribbons (3D GNRs) using solution based covalent binding of individual 2D GNRs and demonstrate its electrochemical application as a 3D electrode. The enhanced performance of 3D GNRs over individual 2D GNRs is established using standard redox probes - [Ru(NH3)6]3+/2+, [Fe(CN)6]3-/4- and important bio-analytes - dopamine and ascorbic acid. 3D GNRs are found to have high double layer capacitance (2482 μF cm-2) and faster electron transfer kinetics; their exceptional electrocatalytic activity towards the oxygen reduction reaction is indicative of their potential over a wide range of electrochemical applications. Moreover, this study opens a new platform for the design of novel point-of-care devices and electrodes for energy devices. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr07315k

  12. Serial block face scanning electron microscopy--the future of cell ultrastructure imaging.

    PubMed

    Hughes, Louise; Hawes, Chris; Monteith, Sandy; Vaughan, Sue

    2014-03-01

    One of the major drawbacks in transmission electron microscopy has been the production of three-dimensional views of cells and tissues. Currently, there is no one suitable 3D microscopy technique that answers all questions and serial block face scanning electron microscopy (SEM) fills the gap between 3D imaging using high-end fluorescence microscopy and the high resolution offered by electron tomography. In this review, we discuss the potential of the serial block face SEM technique for studying the three-dimensional organisation of animal, plant and microbial cells.

  13. Joint Services Electronics Program Research in Electronics (University of Southern California, Electronic Sciences Laboratory)

    DTIC Science & Technology

    1990-01-05

    submitted). 3. 0. J. Kim, A. Madhukar, W. Chen, K. Z. Hu, "Realization of High Mobilities at Ultra Low Electron Density in GaAs-Al O.3GaO.7As Inverted...to-Coherent Optical Conversion", in Photorefractive Materials and Aplications , J. P. Huignard and P. Gunter, Eds., Springer-Verlag, New York (1989). 2...Schottky Barrier Epitaxial Structures," USC Ph.D. Thesis (May 1989). 2. E. Garmire, N. M. Jokerst, A. Kost, A. Dar,---, and P. D. Dapkus, "Optical

  14. Van der Waals Epitaxy of Functional Oxide Heterostructures

    NASA Astrophysics Data System (ADS)

    Chu, Ying-Hao

    In the diligent pursuit of low-power consumption, multifunctional, and environmentally friendly electronics, more sophisticated requirements on functional materials are on demand. Recently, the discovery of 2D layered materials has created a revolution to this field. Pioneered by graphene, these new 2D materials exhibit abundant unusual physical phenomena that is undiscovered in bulk forms. These materials are characterized with their layer form and almost pure 2D electronic behavior. The confinement of charge and heat transport at such ultrathin planes offers possibilities to overcome the bottleneck of present device development in thickness limitation, and thus push the technologies into next generation. Van der Waals epitaxy, an epitaxial growth method to combine 2D and 3D materials, is one of current reliable manufacturing processes to fabricate 2D materials by growing these 2D materials epitaxially on 3D materials. Then, transferring the 2D materials to the substrates for practical applications. In the mean time, van der Waals epitaxy has also been used to create free-standing 3D materials by growing 3D materials on 2D materials and then removing them from 2D materials since the interfacial boding between 2D and 3D materials should be weak van der Waals bonds. In this study, we intend to take the same concept, but to integrate a family of functional materials in order to open new avenue to flexible electronics. Due to the interplay of lattice, charge, orbital, and spin degrees of freedom, correlated electrons in oxides generate a rich spectrum of competing phases and physical properties. Recently, lots of studies have suggested that oxide heterostructures provide a powerful route to create and manipulate the degrees of freedom and offer new possibilities for next generation devices, thus create a new playground for researchers to investigate novel physics and the emergence of fascinating states of condensed matter. In this talk, we use a 2D layered material as the substrate. And we take several oxides as examples to demonstrate a pathway to integrate 3D functional oxides on 2D layered materials.

  15. Collision-Driven Negative-Energy Waves and the Weibel Instability of a Relativistic Electron Beam in a Quasineutral Plasma

    NASA Astrophysics Data System (ADS)

    Karmakar, Anupam; Kumar, Naveen; Shvets, Gennady; Polomarov, Oleg; Pukhov, Alexander

    2008-12-01

    A new model describing the Weibel instability of a relativistic electron beam propagating through a resistive plasma is developed. For finite-temperature beams, a new class of negative-energy magnetosound waves is identified, whose growth due to collisional dissipation destabilizes the beam-plasma system even for high beam temperatures. We perform 2D and 3D particle-in-cell simulations and show that in 3D geometry the Weibel instability persists even for collisionless background plasma. The anomalous plasma resistivity in 3D is caused by the two-stream instability.

  16. Multiconfiguration Dirac-Hartree-Fock calculations of energy levels and radiative rates of Fe VII

    NASA Astrophysics Data System (ADS)

    Li, Yang; Xu, Xiaokai; Li, Bowen; Jönsson, Per; Chen, Ximeng

    2018-06-01

    Detailed calculations are performed for 134 fine-structure levels of the 3p63d2, 3p63d4s, 3p53d3 and 3p63d4p configurations in Fe VII using the multiconfiguration Dirac-Hartree-Fock (MCDHF) and relativistic configuration interaction (RCI) methods. Important electron correlation effects are systematically accounted for through active space (AS) expansions. Our results compare well with experimental measurements, emphasizing the importance of a careful treatment of electron correlation, and provide some missing data in the NIST atomic database. The data obtained are expected to be useful in astrophysical applications, particularly for the research of the solar coronal plasma.

  17. Registering 2D and 3D imaging data of bone during healing.

    PubMed

    Hoerth, Rebecca M; Baum, Daniel; Knötel, David; Prohaska, Steffen; Willie, Bettina M; Duda, Georg N; Hege, Hans-Christian; Fratzl, Peter; Wagermaier, Wolfgang

    2015-04-01

    PURPOSE/AIMS OF THE STUDY: Bone's hierarchical structure can be visualized using a variety of methods. Many techniques, such as light and electron microscopy generate two-dimensional (2D) images, while micro-computed tomography (µCT) allows a direct representation of the three-dimensional (3D) structure. In addition, different methods provide complementary structural information, such as the arrangement of organic or inorganic compounds. The overall aim of the present study is to answer bone research questions by linking information of different 2D and 3D imaging techniques. A great challenge in combining different methods arises from the fact that they usually reflect different characteristics of the real structure. We investigated bone during healing by means of µCT and a couple of 2D methods. Backscattered electron images were used to qualitatively evaluate the tissue's calcium content and served as a position map for other experimental data. Nanoindentation and X-ray scattering experiments were performed to visualize mechanical and structural properties. We present an approach for the registration of 2D data in a 3D µCT reference frame, where scanning electron microscopies serve as a methodic link. Backscattered electron images are perfectly suited for registration into µCT reference frames, since both show structures based on the same physical principles. We introduce specific registration tools that have been developed to perform the registration process in a semi-automatic way. By applying this routine, we were able to exactly locate structural information (e.g. mineral particle properties) in the 3D bone volume. In bone healing studies this will help to better understand basic formation, remodeling and mineralization processes.

  18. Ultrasonic drilling apparatus

    DOEpatents

    Duran, E.L.; Lundin, R.L.

    1988-06-20

    Apparatus attachable to an ultrasonic drilling machine for drilling deep holes in very hard materials, such as boron carbide, is provided. The apparatus utilizes a hollow spindle attached to the output horn of the ultrasonic drilling machine. The spindle has a hollow drill bit attached at the opposite end. A housing surrounds the spindle, forming a cavity for holding slurry. In operation, slurry is provided into the housing, and into the spindle through inlets while the spindle is rotating and ultrasonically reciprocating. Slurry flows through the spindle and through the hollow drill bit to cleanse the cutting edge of the bit during a drilling operation. 3 figs.

  19. Application of protease technology in dermatology: rationale for incorporation into skin care with initial observations on formulations designed for skin cleansing, maintenance of hydration, and restoration of the epidermal permeability barrier.

    PubMed

    Del Rosso, James Q

    2013-06-01

    This article reviews background on proteases and their functions, their physiological significance in skin, and the potential implications of incorporating specific proteases and protease blends into dermatological products, including skin care formulations. The history of protease blend formulations used in wound model studies and for other disorders is reviewed. In vitro data with use of a specific 3-protease blend with evaluation of the impact on various skin proteins and peptides is also discussed in this article.

  20. Element-specific observation of the ferromagnetic ordering process in UCoAl via soft x-ray magnetic circular dichroism

    NASA Astrophysics Data System (ADS)

    Takeda, Yukiharu; Saitoh, Yuji; Okane, Tetsuo; Yamagami, Hiroshi; Matsuda, Tatsuma D.; Yamamoto, Etsuji; Haga, Yoshinori; Ōnuki, Yoshichika

    2018-05-01

    We have performed soft x-ray magnetic circular dichroism (XMCD) experiments on the itinerant-electron metamagnet UCoAl at the U 4 d -5 f (N4 ,5) and Co 2 p -3 d (L2 ,3) absorption edges in order to investigate the magnetic properties of the U 5 f and Co 3 d electrons separately. From the line shape of the XMCD spectrum, it is deduced that the orbital magnetic moment of the Co 3 d electrons is unusually large. Through the systematic temperature (T )- and magnetic field (H )-dependent XMCD measurements, we have obtained two types of the magnetization curve as a function of H and T (M-H curve and M-T curve, respectively). The metamagnetic transition from a paramagnetic state to a field-induced ferromagnetic state was clearly observed under 15 K at HM. The value of the HM and its T dependence agree well between the U and Co sites, and the bulk magnetization. Whereas, we have discovered the remarkable differences in the M-H and M-T curves between the U and Co sites. The present findings clearly show that the role of the Co 3 d electrons should be considered more carefully in order to understand the origin of the magnetic ordering in UCoAl.

  1. Density Functional Study on A-Units Based on Thieno[3,4- c]pyrrole-4,6-dione for Organic Solar Cells

    NASA Astrophysics Data System (ADS)

    Tang, Xiaoqin; Shen, Wei; Fu, Zhiyong; Liu, Xiaorui; Li, Ming

    2017-08-01

    The use of polymer donor materials has allowed great progress in organic solar cells. To search for potential donor materials, we have designed a series of donor-acceptor (D-A)-type alternating polymers composed of dithieno[3,2- b:2',3'- d]pyrrole (DTP) electron-rich units and thieno[3,4- c]pyrrole-4,6-dione (TPD) electron-deficient units. Their electronic and optical properties have been investigated using density functional theory and Marcus theory. The calculation results demonstrate that introduction of cyclic compounds (furyl, thienyl, and phenyl) into electron-deficient units of the molecules can result in lower highest occupied molecular orbital (HOMO) levels and reorganization energies compared with the experimental molecule ( X 0 ). To investigate the effects of electron-withdrawing units, three electron-withdrawing substituents (-OCH3, -F, and -CN) were introduced into the thienyl. The results indicated that the polymer X 2-3 will show the best performance among the designed polymers, offering low-lying HOMO energy level (-5.47 eV), narrow energy gap (1.97 eV), and high hole mobility (7.45 × 10-2 cm2 V-1 s-1). This work may provide a guideline for the design of efficient D-A polymers for organic solar cells with enhanced performance.

  2. 3D image reconstruction algorithms for cryo-electron-microscopy images of virus particles

    NASA Astrophysics Data System (ADS)

    Doerschuk, Peter C.; Johnson, John E.

    2000-11-01

    A statistical model for the object and the complete image formation process in cryo electron microscopy of viruses is presented. Using this model, maximum likelihood reconstructions of the 3D structure of viruses are computed using the expectation maximization algorithm and an example based on Cowpea mosaic virus is provided.

  3. Preservation of protein fluorescence in embedded human dendritic cells for targeted 3D light and electron microscopy

    PubMed Central

    HÖHN, K.; FUCHS, J.; FRÖBER, A.; KIRMSE, R.; GLASS, B.; ANDERS‐ÖSSWEIN, M.; WALTHER, P.; KRÄUSSLICH, H.‐G.

    2015-01-01

    Summary In this study, we present a correlative microscopy workflow to combine detailed 3D fluorescence light microscopy data with ultrastructural information gained by 3D focused ion beam assisted scanning electron microscopy. The workflow is based on an optimized high pressure freezing/freeze substitution protocol that preserves good ultrastructural detail along with retaining the fluorescence signal in the resin embedded specimens. Consequently, cellular structures of interest can readily be identified and imaged by state of the art 3D confocal fluorescence microscopy and are precisely referenced with respect to an imprinted coordinate system on the surface of the resin block. This allows precise guidance of the focused ion beam assisted scanning electron microscopy and limits the volume to be imaged to the structure of interest. This, in turn, minimizes the total acquisition time necessary to conduct the time consuming ultrastructural scanning electron microscope imaging while eliminating the risk to miss parts of the target structure. We illustrate the value of this workflow for targeting virus compartments, which are formed in HIV‐pulsed mature human dendritic cells. PMID:25786567

  4. 3D correlative light and electron microscopy of cultured cells using serial blockface scanning electron microscopy

    PubMed Central

    Lerner, Thomas R.; Burden, Jemima J.; Nkwe, David O.; Pelchen-Matthews, Annegret; Domart, Marie-Charlotte; Durgan, Joanne; Weston, Anne; Jones, Martin L.; Peddie, Christopher J.; Carzaniga, Raffaella; Florey, Oliver; Marsh, Mark; Gutierrez, Maximiliano G.

    2017-01-01

    ABSTRACT The processes of life take place in multiple dimensions, but imaging these processes in even three dimensions is challenging. Here, we describe a workflow for 3D correlative light and electron microscopy (CLEM) of cell monolayers using fluorescence microscopy to identify and follow biological events, combined with serial blockface scanning electron microscopy to analyse the underlying ultrastructure. The workflow encompasses all steps from cell culture to sample processing, imaging strategy, and 3D image processing and analysis. We demonstrate successful application of the workflow to three studies, each aiming to better understand complex and dynamic biological processes, including bacterial and viral infections of cultured cells and formation of entotic cell-in-cell structures commonly observed in tumours. Our workflow revealed new insight into the replicative niche of Mycobacterium tuberculosis in primary human lymphatic endothelial cells, HIV-1 in human monocyte-derived macrophages, and the composition of the entotic vacuole. The broad application of this 3D CLEM technique will make it a useful addition to the correlative imaging toolbox for biomedical research. PMID:27445312

  5. 4D computerized ionospheric tomography by using GPS measurements and IRI-Plas model

    NASA Astrophysics Data System (ADS)

    Tuna, Hakan; Arikan, Feza; Arikan, Orhan

    2016-07-01

    Ionospheric imaging is an important subject in ionospheric studies. GPS based TEC measurements provide very accurate information about the electron density values in the ionosphere. However, since the measurements are generally very sparse and non-uniformly distributed, computation of 3D electron density estimation from measurements alone is an ill-defined problem. Model based 3D electron density estimations provide physically feasible distributions. However, they are not generally compliant with the TEC measurements obtained from GPS receivers. In this study, GPS based TEC measurements and an ionosphere model known as International Reference Ionosphere Extended to Plasmasphere (IRI-Plas) are employed together in order to obtain a physically accurate 3D electron density distribution which is compliant with the real measurements obtained from a GPS satellite - receiver network. Ionospheric parameters input to the IRI-Plas model are perturbed in the region of interest by using parametric perturbation models such that the synthetic TEC measurements calculated from the resultant 3D electron density distribution fit to the real TEC measurements. The problem is considered as an optimization problem where the optimization parameters are the parameters of the parametric perturbation models. Proposed technique is applied over Turkey, on both calm and storm days of the ionosphere. Results show that the proposed technique produces 3D electron density distributions which are compliant with IRI-Plas model, GPS TEC measurements and ionosonde measurements. The effect of the GPS receiver station number on the performance of the proposed technique is investigated. Results showed that 7 GPS receiver stations in a region as large as Turkey is sufficient for both calm and storm days of the ionosphere. Since the ionization levels in the ionosphere are highly correlated in time, the proposed technique is extended to the time domain by applying Kalman based tracking and smoothing approaches onto the obtained results. Combining Kalman methods with the proposed 3D CIT technique creates a robust 4D ionospheric electron density estimation model, and has the advantage of decreasing the computational cost of the proposed method. Results applied on both calm and storm days of the ionosphere show that, new technique produces more robust solutions especially when the number of GPS receiver stations in the region is small. This study is supported by TUBITAK 114E541, 115E915 and Joint TUBITAK 114E092 and AS CR 14/001 projects.

  6. Heterobimetallic Complexes That Bond Vanadium to Iron, Cobalt, and Nickel.

    PubMed

    Clouston, Laura J; Bernales, Varinia; Cammarota, Ryan C; Carlson, Rebecca K; Bill, Eckhard; Gagliardi, Laura; Lu, Connie C

    2015-12-21

    Zero-valent iron, cobalt, and nickel were installed into the metalloligand V[N(o-(NCH2P((i)Pr)2)C6H4)3] (1, VL), generating the heterobimetallic trio FeVL (2), CoVL (3), and NiVL (4), respectively. In addition, the one-electron-oxidized analogues [FeVL]X ([2(ox)]X, where X(-) = BPh4 or PF6) and [CoVL]BPh4 ([3(ox)]BPh4) were prepared. The complexes were characterized by a host of physical methods, including cyclic voltammetry, X-ray crystallography, magnetic susceptibility, electronic absorption, NMR, electron paramagnetic resonance (EPR), and Mössbauer spectroscopies. The CoV and FeV heterobimetallic compounds have short M-V bond lengths that are consistent with M-M multiple bonding. As revealed by theoretical calculations, the M-V bond is triple in 2, 2(ox), and 3(ox), double in 3, and dative (Ni → V) in 4. The (d-d)(10) species, 2 and 3(ox), are diamagnetic and exhibit large diamagnetic anisotropies of -4700 × 10(-36) m(3)/molecule. Complexes 2 and 3(ox) are also characterized by intense visible bands at 760 and 610 nm (ε > 1000 M(-1) cm(-1)), respectively, which correspond to an intermetal (M → V) charge-transfer transition. Magnetic susceptibility measurements and EPR characterization establish S = (1)/2 ground states for (d-d)(9) 2(ox) and (d-d)(11) 3, while (d-d)(12) 4 is S = 1 based on Evans' method.

  7. Probing collective oscillation of d-orbital electrons at the nanoscale

    NASA Astrophysics Data System (ADS)

    Dhall, Rohan; Vigil-Fowler, Derek; Houston Dycus, J.; Kirste, Ronny; Mita, Seiji; Sitar, Zlatko; Collazo, Ramon; LeBeau, James M.

    2018-02-01

    Here, we demonstrate that high energy electrons can be used to explore the collective oscillation of s, p, and d orbital electrons at the nanometer length scale. Using epitaxial AlGaN/AlN quantum wells as a test system, we observe the emergence of additional features in the loss spectrum with the increasing Ga content. A comparison of the observed spectra with ab-initio theory reveals that the origin of these spectral features lies in excitations of 3d-electrons contributed by Ga. We find that these modes differ in energy from the valence electron plasmons in Al1-xGaxN due to the different polarizabilities of the d electrons. Finally, we study the dependence of observed spectral features on the Ga content, lending insights into the origin of these spectral features, and their coupling with electron-hole excitations.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, David; Rickey, Daniel; Dubey, Arbind

    Purpose: We describe the process by which our centre is currently implementing 3D printing and scanning technology for treatment accessory fabrication. This technology can increase efficiency and accuracy of accessory design, production and placement during daily use. Methods: A low-cost 3D printer and 3D optical scanner have been purchased and are being commissioned for clinical use. Commissioning includes assessing: the accuracy of the 3D scanner through comparison with high resolution CT images; the dosimetric characteristics of polylactic acid (PLA) for electron beams; the clinical utility of the technology, and; methods for quality assurance. Results: The agreement between meshes generated usingmore » the 3D scanner and CT data was within 2 millimeters for an anthropomorphic head phantom. In terms of electron beam attenuation, 1 centimetre of printed PLA was found equivalent to 1.17 cm of water. In proof-of-concept tests, several types of treatment accessories have been prototyped to date that will benefit from this technology. These include electron and photon bolus for areas with complex surface contours including the ear for electron treatments, the extremities for photon treatments and lead shielding for orthovoltage treatments. Imaging with CT and x-ray showed minimal defects, which will have no significant clinical impact. Geometric fidelity and fit to volunteers and patients was found to be excellent. Conclusions: 3D Printing and scanning can increase efficiency in the clinic for treatments requiring custom accessories. Customized boluses and shielding had excellent fit and reduced uncertainty in positioning.« less

  9. Dissipationless transport of spin-polarized electrons and Cooper pairs in an electron waveguide

    NASA Astrophysics Data System (ADS)

    Levy, J.; Annadi, A.; Lu, S.; Cheng, G.; Tylan-Tyler, A.; Briggeman, M.; Tomczyk, M.; Huang, M.; Pekker, D.; Irvin, P.; Lee, H.; Lee, J.-W.; Eom, C.-B.

    Electron systems undergo profound changes in their behavior when constrained to move along a single axis. To date, clean one-dimensional (1D) electron transport has only been observed in carbon-based nanotubes and nanoribbons, and compound semiconductor nanowires. Complex-oxide heterostructures can possess conductive two-dimensional (2D) interfaces with much richer chemistries and properties, e.g., superconductivity, but with mobilities that appear to preclude ballistic transport in 1D. Here we show that nearly ideal 1D electron waveguides exhibiting ballistic transport of electrons and non-superconducting Cooper pairs can be formed at the interface between the two band insulators LaAlO3 and SrTiO3. The electron waveguides possess gate and magnetic-field selectable spin and charge degrees of freedom, and can be tuned to the one-dimensional limit of a single spin-polarized quantum channel. The strong attractive electron-electron interactions enable a new mode of dissipationless transport of electron pairs that is not superconducting. The selectable spin and subband quantum numbers of these electron waveguides may be useful for quantum simulation, quantum informatio We gratefully acknowledge financial support from ONR N00014-15-1-2847 (JL), AFOSR (FA9550-15-1-0334 (CBE) and FA9550-12-1-0057 (JL, CBE)), AOARD FA2386-15-1-4046 (CBE) and NSF (DMR-1104191 (JL), DMR-1124131 (CBE, JL) and DMR-1234096 (CBE)).

  10. Serial sectioning methods for 3D investigations in materials science.

    PubMed

    Zankel, Armin; Wagner, Julian; Poelt, Peter

    2014-07-01

    A variety of methods for the investigation and 3D representation of the inner structure of materials has been developed. In this paper, techniques based on slice and view using scanning microscopy for imaging are presented and compared. Three different methods of serial sectioning combined with either scanning electron or scanning ion microscopy or atomic force microscopy (AFM) were placed under scrutiny: serial block-face scanning electron microscopy, which facilitates an ultramicrotome built into the chamber of a variable pressure scanning electron microscope; three-dimensional (3D) AFM, which combines an (cryo-) ultramicrotome with an atomic force microscope, and 3D FIB, which delivers results by slicing with a focused ion beam. These three methods complement one another in many respects, e.g., in the type of materials that can be investigated, the resolution that can be obtained and the information that can be extracted from 3D reconstructions. A detailed review is given about preparation, the slice and view process itself, and the limitations of the methods and possible artifacts. Applications for each technique are also provided. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. High-Fidelity 3D-Nanoprinting via Focused Electron Beams: Growth Fundamentals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winkler, Robert; Lewis, Brett B.; Fowlkes, Jason Davidson

    While 3D-printing is currently experiencing significant growth and having a significant impact on science and technology, the expansion into the nanoworld is still a highly challenging task. Among the increasing number of approaches, focused electron-beam-induced deposition (FEBID) was recently demonstrated to be a viable candidate toward a generic direct-write fabrication technology with spatial nanometer accuracy for complex shaped 3D-nanoarchitectures. In this comprehensive study, we explore the parameter space for 3D-FEBID and investigate the implications of individual and interdependent parameters on freestanding nanosegments, which act as a fundamental building block for complex 3D-structures. In particular, the study provides new basic insightsmore » such as precursor transport limitations and angle dependent growth rates, both essential for high-fidelity fabrication. In conclusion, complemented by practical aspects, we provide both basic insights in 3D-growth dynamics and technical guidance for specific process adaption to enable predictable and reliable direct-write synthesis of freestanding 3D-nanoarchitectures.« less

  12. High-Fidelity 3D-Nanoprinting via Focused Electron Beams: Growth Fundamentals

    DOE PAGES

    Winkler, Robert; Lewis, Brett B.; Fowlkes, Jason Davidson; ...

    2018-02-14

    While 3D-printing is currently experiencing significant growth and having a significant impact on science and technology, the expansion into the nanoworld is still a highly challenging task. Among the increasing number of approaches, focused electron-beam-induced deposition (FEBID) was recently demonstrated to be a viable candidate toward a generic direct-write fabrication technology with spatial nanometer accuracy for complex shaped 3D-nanoarchitectures. In this comprehensive study, we explore the parameter space for 3D-FEBID and investigate the implications of individual and interdependent parameters on freestanding nanosegments, which act as a fundamental building block for complex 3D-structures. In particular, the study provides new basic insightsmore » such as precursor transport limitations and angle dependent growth rates, both essential for high-fidelity fabrication. In conclusion, complemented by practical aspects, we provide both basic insights in 3D-growth dynamics and technical guidance for specific process adaption to enable predictable and reliable direct-write synthesis of freestanding 3D-nanoarchitectures.« less

  13. Chalazion

    MedlinePlus

    ... you may have a small notch in the edge of the eyelid. The most common complication is ... It may help to gently scrub the edge of the lid at the eyelash line nightly to prevent chalazia or styes. Use eye cleansing pads or diluted baby shampoo. Apply antibiotic ...

  14. Colyte and Colyte-flavored (PEG-3350 & electrolytes) for oral solution for gastrointestinal lavage.

    PubMed

    Pickering, P

    1994-06-01

    Colyte and Colyte-flavored are effective in preparing the bowel for endoscopic examination, particularly when used in combination with saline and stimulant laxatives, which may decrease the volume of Colyte required for optimal bowel cleansing.

  15. Diffusion pump modification promotes self-cleansing and high efficiency

    NASA Technical Reports Server (NTRS)

    Buggele, A. E.

    1975-01-01

    Modifications eliminate contaminant substances from pump fluid during operation, which are principal causes of torpidity on evaporative surface. Diffusion pump is also acting as still. Resulting 100 percent vigorous working surface provides much greater molecular throughput and greatly improved efficiency.

  16. Electronic and magnetic behaviors of B, N, and 3d transition metal substitutions in germanium carbide monolayer

    NASA Astrophysics Data System (ADS)

    Xu, Zhuo; Li, Yangping; Liu, Zhengtang; Liu, Shengzhong (Frank)

    2018-04-01

    The structural, electronic, and magnetic behaviors of two-dimensional GeC (2D-GeC) with single vacancy, substitutional B, N, and 3d transition metal atoms (Sc, Ti, V, Cr, Mn, Fe, Co, and Ni) are investigated based on the density functional theory. These impurities are tightly bonded to the surrounding atoms and found energetically more favorable at Ge sub-lattice site. In addition, the electronic band structures and magnetic properties of the doped systems indicate that (i) tunable electronic structures and magnetic moments of 2D-GeC can be obtained depending on different dopant species and sub-lattice sites, (ii) systems such as VC@Sc, VC@Fe, VC@Co, VGe@Fe, and VGe@Co are found to be half-metals, while the other systems all show semiconductor behavior. Simple models of the impurity-vacancy interaction is put forwards to illustrate the origin of the electronic structures and magnetic moments.

  17. Electronic and optical properties of graphene-like InAs: An ab initio study

    NASA Astrophysics Data System (ADS)

    Sohrabi, Leila; Boochani, Arash; Ali Sebt, S.; Mohammad Elahi, S.

    2018-03-01

    The present work initially investigates structural, optical, and electronic properties of graphene-like InAs by using the full potential linear augmented plane wave method in the framework of density functional theory and is then compared with the bulk Indium Arsenide in the wurtzite phase. The lattice parameters are optimized with GGA-PBE and LDA approximations for both 2D- and 3D-InAs. In order to study the electronic properties of graphene-like InAs and bulk InAs in the wurtzite phase, the band gap is calculated by GGA-PBG and GGA-EV approximations. Moreover, optical parameters of graphene-like InAs and bulk InAs such as the real and imaginary parts of dielectric function, electron energy loss function, refractivity, extinction and absorption coefficients, and optical conductivity are investigated. Plasmonic frequencies of 2D- and 3D-InAs are also calculated by using maximum electron energy loss function and the roots of the real part of the dielectric function.

  18. Topology of the electron density of d0 transition metal compounds at subatomic resolution.

    PubMed

    Batke, Kilian; Eickerling, Georg

    2013-11-14

    Accurate X-ray diffraction experiments allow for a reconstruction of the electron density distribution of solids and molecules in a crystal. The basis for the reconstruction of the electron density is in many cases a multipolar expansion of the X-ray scattering factors in terms of spherical harmonics, a so-called multipolar model. This commonly used ansatz splits the total electron density of each pseudoatom in the crystal into (i) a spherical core, (ii) a spherical valence, and (iii) a nonspherical valence contribution. Previous studies, for example, on diamond and α-silicon have already shown that this approximation is no longer valid when ultrahigh-resolution diffraction data is taken into account. We report here the results of an analysis of the calculated electron density distribution in the d(0) transition metal compounds [TMCH3](2+) (TM = Sc, Y, and La) at subatomic resolution. By a detailed molecular orbital analysis, it is demonstrated that due to the radial nodal structure of the 3d, 4d, and 5d orbitals involved in the TM-C bond formation a significant polarization of the electron density in the inner electronic shells of the TM atoms is observed. We further show that these polarizations have to be taken into account by an extended multipolar model in order to recover accurate electron density distributions from high-resolution structure factors calculated for the title compounds.

  19. Dual nature of 3 d electrons in YbT 2 Zn 20 (T = Co; Fe) evidenced by electron spin resonance

    DOE PAGES

    Ivanshin, V. A.; Litvinova, T. O.; Gimranova, K.; ...

    2015-03-18

    The electron spin resonance experiments were carried out in the single crystals YbFe 2Zn 20. The observed spin dynamics is compared with that in YbCo 2Zn 20 and Yb 2Co 12P 7 as well as with the data of inelastic neutron scattering and electronic band structure calculations. Our results provide direct evidence that 3d electrons are itinerant in YbFe 2Zn 20 and localized in YbCo 2Zn 20. Possible connection between spin paramagnetism of dense heavy fermion systems, quantum criticality effects, and ESR spectra is discussed.

  20. Density-functional theory applied to d- and f-electron systems

    NASA Astrophysics Data System (ADS)

    Wu, Xueyuan

    Density functional theory (DFT) has been applied to study the electronic and geometric structures of prototype d- and f-electron systems. For the d-electron system, all electron DFT with gradient corrections to the exchange and correlation functionals has been used to investigate the properties of small neutral and cationic vanadium clusters. Results are in good agreement with available experimental and other theoretical data. For the f-electron system, a hybrid DFT, namely, B3LYP (Becke's 3-parameter hybrid functional using the correlation functional of Lee, Yang and Parr) with relativistic effective core potentials and cluster models has been applied to investigate the nature of chemical bonding of both the bulk and the surfaces of plutonium monoxide and dioxide. Using periodic models, the electronic and geometric structures of PuO2 and its (110) surface, as well as water adsorption on this surface have also been investigated using DFT in both local density approximation (LDA) and generalized gradient approximation (GGA) formalisms.

  1. The electronic structure of d{sup 6} metal-acetylides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Renshaw, S.K.; Uplinger, A.B.; Bullock, R.M.

    1997-12-31

    Gas-phase ultraviolet photoelectron spectroscopy has been used to investigate the electronic structure and bonding interactions of d{sup 6} piano-stool metal-acetylides of the general formulas CpML{sub 2}C{triple_bond} C-R [M = Ru, L = PMe{sub 3}, R = H, Me, {sup t}Bu, C{sub 6}H{sub 5}] and CpML{sub 2}C{triple_bond}C-p-C{sub 6}H{sub 4}-NO{sub 2} [M = Fe, Ru, L = CO; M = Ru, L = PMe{sub 3}]. Previous studies of analogous CpFe(CO){sub 2}C{triple_bond}C-R complexes found that the filled-filled interaction between the metal d electrons and the acetylide {pi} bond electrons dominates the shift of the first valence ionizations, and that backbonding of the metalmore » d electrons into the acetylide {pi}* orbitals is very small. It is found here that the change to the second row transition metal and the substitution of phosphines for the carbonyls makes the metal more electron rich, but does not change the basic description of the metal interaction with the acetylide.« less

  2. Ultrastructure in frozen/etched saline solutions: on the internal cleansing of ice.

    PubMed

    Menger, Fredric M; Galloway, Ashley L; Chlebowski, Mary E; Apkarian, Robert P

    2004-05-19

    Seawater, with its 3.5% salt content, freezes into hexagonal ice (Ih) that encloses concentrated brine within its matrix. When unsubmerged sea ice reaches a certain height and temperature, the brine drains downward through narrow channels. This mechanism was now modeled by frozen 2-3.5% saline as investigated by cryo-etch high-resolution secondary electron microscopy. Thus, saline was either plunge-frozen in liquid ethane at -183 degrees C or else high-pressure frozen to -105 degrees C in 5-6 ms. Ice from a freshly exposed surface was then subjected to a high-vacuum sublimation ("etching"), a procedure that removes pure bulk ice in preference to ice from frozen hydrated salt. After chromium-coating the etched surface with a 2-nm film, the sample was examined by cryo-HRSEM. Granular icy "fences" were seen surrounding empty areas where amorphous ice had originally resided. Since the fences, about 1-2 mum high, survived the etching, it is likely that they consist of frozen brine. The presence of such fences suggests that, during freezing, saline can purge itself of salt with remarkable speed (5-6 ms). Alternatively, channels (perhaps routed around submicroscopic crystallites of cubic ice (Ic) embedded in the amorphous ice at -105 degrees C) can guide the migration of salt to the periphery of ice patches. Macromolecules fail to form fences because they diffuse too slowly or because they are too large to pass through the channels.

  3. Directed high-power THz radiation from transverse laser wakefield excited in an electron density filament

    NASA Astrophysics Data System (ADS)

    Kalmykov, Serge; Englesbe, Alexander; Elle, Jennifer; Domonkos, Matthew; Schmitt-Sody, Andreas

    2017-10-01

    A tightly focused femtosecond, weakly relativistic laser pulse partially ionizes the ambient gas, creating a string (a ``filament'') of electron density, locally reducing the nonlinear index and compensating for the self-focusing effect caused by bound electrons. While maintaining the filament over many Rayleigh lengths, the pulse drives inside it a three-dimensional (3D) wave of charge separation - the plasma wake. If the pulse waist size is much smaller than the Langmuir wavelength, electron current in the wake is mostly transverse. Electrons, driven by the wake across the sharp radial boundary of the filament, lose coherence within 2-3 periods of wakefield oscillations, and the wake decays. The laser pulse is thus accompanied by a short-lived, almost aperiodic electron current coupled to the sharp index gradient. The comprehensive 3D hydrodynamic model shows that this structure emits a broad-band THz radiation, with the highest power emitted in the near-forward direction. The THz radiation pattern contains information on wake currents surrounding the laser pulse, thus serving as an all-optical diagnostic tool. The results are tested in cylindrical and full 3D PIC simulations using codes WAKE and EPOCH.

  4. Nearest-neighbor Kitaev exchange blocked by charge order in electron-doped α -RuCl3

    NASA Astrophysics Data System (ADS)

    Koitzsch, A.; Habenicht, C.; Müller, E.; Knupfer, M.; Büchner, B.; Kretschmer, S.; Richter, M.; van den Brink, J.; Börrnert, F.; Nowak, D.; Isaeva, A.; Doert, Th.

    2017-10-01

    A quantum spin liquid might be realized in α -RuCl3 , a honeycomb-lattice magnetic material with substantial spin-orbit coupling. Moreover, α -RuCl3 is a Mott insulator, which implies the possibility that novel exotic phases occur upon doping. Here, we study the electronic structure of this material when intercalated with potassium by photoemission spectroscopy, electron energy loss spectroscopy, and density functional theory calculations. We obtain a stable stoichiometry at K0.5RuCl3 . This gives rise to a peculiar charge disproportionation into formally Ru2 + (4 d6 ) and Ru3 + (4 d5 ). Every Ru 4 d5 site with one hole in the t2 g shell is surrounded by nearest neighbors of 4 d6 character, where the t2 g level is full and magnetically inert. Thus, each type of Ru site forms a triangular lattice, and nearest-neighbor interactions of the original honeycomb are blocked.

  5. Following an electron bunch for free electron laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2012-01-01

    A video artist's ultra-slow-motion impression of an APEX-style electron gun firing a continuous train of electron bunches into a superconducting linear accelerator (in reality this would happen a million times a second). As they approach the speed of light the bunches contract, maintaining beam quality. After acceleration, the electron bunches are diverted into one or more undulators, the key components of free electron lasers. Oscillating back and forth in the changing magnetic field, they create beams of structured x-ray pulses. Before entering the experimental areas the electron bunches are diverted to a beam dump. (Animation created by Illumina Visual, http://www.illuminavisual.com/,more » for Lawrence Berkeley National Laboratory. Music for this excerpt, "Feeling Dark (Behind The Mask)" is by 7OOP3D http://ccmixter.org/files/7OOP3D/29126 and is licensed under a Creative Commons license: http://creativecommons.org/licenses/by-nc/3.0/)« less

  6. Atomic Data and Spectral Line Intensities for Ni XI

    NASA Technical Reports Server (NTRS)

    Bhatia, A. K.; Landi, E.

    2010-01-01

    Electron impact collision strengths, energy levels, oscillator strengths and spontaneous radiative decay rates are calculated for Ni XI. We include in the calculations the 10 lowest configurations, corresponding to 164 fine structure levels: 3s(sup 2)3p(sup 6), 3s(sup 2)3p(sup 5)3d, 3s(sup 2)3p(sup 4)3d(sup 2), 3s3p(sup 6)3d, 3s(sup 2)3p(sup 5)4l and 3s3p6 4l with l =.s, p, d. Collision strengths are calculated at five incident energies for all transitions: 7.1, 16.8, 30.2, 48.7 and 74.1 Ry above the threshold of each transition. An additional energy, very close to the transition threshold, has been added, whose value is between 0.06 Ry and 0.25 Ry depending on the lower level. Calculations have been carried out using the Flexible Atomic Code and the distorted wave approximation. Excitation rate coefficients are calculated as a function of electron temperature by assuming a Maxwellian electron velocity distribution. Using the excitation rate coefficients and the radiative transition rates of the present work, combined with Close Coupling collision excitation rate coefficient available in the literature for the lowest 17 levels, statistical equilibrium equations for level populations are solved at electron densities covering the 10(exp 8)-10(exp 14) cu cm range and at an electron temperature of logT(sub c)(K)=6.1, corresponding to the maximum abundance of Ni XI. Spectral line intensities are calculated, and their diagnostic relevance is discussed. This dataset will be made available in the next version of the CHIANTI database.

  7. In-situ straining and time-resolved electron tomography data acquisition in a transmission electron microscope.

    PubMed

    Hata, S; Miyazaki, S; Gondo, T; Kawamoto, K; Horii, N; Sato, K; Furukawa, H; Kudo, H; Miyazaki, H; Murayama, M

    2017-04-01

    This paper reports the preliminary results of a new in-situ three-dimensional (3D) imaging system for observing plastic deformation behavior in a transmission electron microscope (TEM) as a directly relevant development of the recently reported straining-and-tomography holder [Sato K et al. (2015) Development of a novel straining holder for transmission electron microscopy compatible with single tilt-axis electron tomography. Microsc. 64: 369-375]. We designed an integrated system using the holder and newly developed straining and image-acquisition software and then developed an experimental procedure for in-situ straining and time-resolved electron tomography (ET) data acquisition. The software for image acquisition and 3D visualization was developed based on the commercially available ET software TEMographyTM. We achieved time-resolved 3D visualization of nanometer-scale plastic deformation behavior in a Pb-Sn alloy sample, thus demonstrating the capability of this system for potential applications in materials science. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Spatial Dimension as a Variable in Quantum Mechanics

    NASA Astrophysics Data System (ADS)

    Doren, Douglas James

    Several approximation methods potentially useful in electronic structure calculations are developed. These methods all treat the spatial dimension, D, as a variable. In an Introduction, the motivations for these methods are described, with special attention to the semiclassical 1/D expansion. Several terms in this expansion have been calculated for two-electron atoms. The results have qualitative appeal but poor convergence properties when D = 3. Chapter 1 shows that this convergence problem is due to singularities in the energy at D = 1 and a method of removing their effects is demonstrated. Chapter 2 treats several model problems, showing how to identify special dimensions at which the energy becomes singular or the Hamiltonian simplifies. Expansions are developed about these special finite values of D which are quite accurate at low order, regardless of the physical parameters of the Hamiltonian. In Chapter 3, expansions about singular points in the energy at finite values of D are used to resum the 1/D series in cases where its leading orders are not sufficient. This leads to a hybrid expansion which typically improves on both the 1/D and the finite D series. These methods are applied in Chapter 4 to two -electron atoms. The ground state energy of few-electron systems is dominated by the presence of a pole when D = 1. The residue of this pole is determined by the eigenvalue of a simple limiting Schrodinger equation. The limit and first order correction are determined for both unapproximated nonrelativistic two-electron atoms and the Hartree-Fock approximation to them. The hybrid expansion using only the first few terms in the 1/D series determines the energy at arbitrary D, providing estimates accurate to four or five figures when D = 3. Degeneracies between D = 3 states and those in nonphysical dimensions are developed in Chapter 5 which provide additional applications for this series. Chapter 6 illustrates these methods in an application to the H(' -) ion, an especially stringent test case. Proposals for future work in this field are described in the final chapter.

  9. Effects of dimensionality on kinetic simulations of laser-ion acceleration in the transparency regime

    NASA Astrophysics Data System (ADS)

    Stark, D. J.; Yin, L.; Albright, B. J.; Guo, F.

    2017-05-01

    A particle-in-cell study of laser-ion acceleration mechanisms in the transparency regime illustrates how two-dimensional (2D) S and P simulations (laser polarization in and out of the simulation plane, respectively) capture different physics characterizing these systems, visible in their entirety often in cost-prohibitive three-dimensional (3D) simulations. The electron momentum anisotropy induced in the target by a laser pulse is dramatically different in the two 2D cases, manifested in differences in target expansion timescales, electric field strengths, and density thresholds for the onset of relativistically induced transparency. In particular, 2D-P simulations exhibit dramatically greater electron heating in the simulation plane, whereas 2D-S ones show a much more isotropic energy distribution, similar to 3D. An ion trajectory analysis allows one to isolate the fields responsible for ion acceleration and to characterize the acceleration regimes in time and space. The artificial longitudinal electron heating in 2D-P exaggerates the effectiveness of target-normal sheath acceleration into its dominant acceleration mechanism throughout the laser-plasma interaction, whereas 2D-S and 3D both have sizable populations accelerated preferentially during transparency.

  10. Effects of dimensionality on kinetic simulations of laser-ion acceleration in the transparency regime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stark, David James; Yin, Lin; Albright, Brian James

    2017-05-03

    A particle-in-cell study of laser-ion acceleration mechanisms in the transparency regime illustrates how two-dimensional (2D) S and P simulations (laser polarization in and out of the simulation plane, respectively) capture different physics characterizing these systems, visible in their entirety in often cost-prohibitive three-dimensional (3D) simulations. The electron momentum anisotropy induced in the target by the laser pulse is dramatically different in the two 2D cases, manifested in differences in target expansion timescales, electric field strengths, and density thresholds for the onset of relativistically induced transparency. In particular, 2D-P simulations exhibit dramatically greater electron heating in the simulation plane, whereas 2D-Smore » ones show a much more isotropic energy distribution, similar to 3D. An ion trajectory analysis allows one to isolate the fields responsible for ion acceleration and to characterize the acceleration regimes in time and space. The artificial longitudinal electron heating in 2D-P exaggerates the effectiveness of target-normal sheath acceleration into its dominant acceleration mechanism throughout the laser-plasma interaction, whereas 2D-S and 3D both have sizable populations accelerated preferentially during transparency.« less

  11. Precision Measurement of the Electron's Electric Dipole Moment Using Trapped Molecular Ions.

    PubMed

    Cairncross, William B; Gresh, Daniel N; Grau, Matt; Cossel, Kevin C; Roussy, Tanya S; Ni, Yiqi; Zhou, Yan; Ye, Jun; Cornell, Eric A

    2017-10-13

    We describe the first precision measurement of the electron's electric dipole moment (d_{e}) using trapped molecular ions, demonstrating the application of spin interrogation times over 700 ms to achieve high sensitivity and stringent rejection of systematic errors. Through electron spin resonance spectroscopy on ^{180}Hf^{19}F^{+} in its metastable ^{3}Δ_{1} electronic state, we obtain d_{e}=(0.9±7.7_{stat}±1.7_{syst})×10^{-29}  e cm, resulting in an upper bound of |d_{e}|<1.3×10^{-28}  e cm (90% confidence). Our result provides independent confirmation of the current upper bound of |d_{e}|<9.4×10^{-29}  e cm [J. Baron et al., New J. Phys. 19, 073029 (2017)NJOPFM1367-263010.1088/1367-2630/aa708e], and offers the potential to improve on this limit in the near future.

  12. High-Fidelity 3D-Nanoprinting via Focused Electron Beams: Computer-Aided Design (3BID)

    DOE PAGES

    Fowlkes, Jason D.; Winkler, Robert; Lewis, Brett B.; ...

    2018-02-14

    Currently, there are few techniques that allow true 3D-printing on the nanoscale. The most promising candidate to fill this void is focused electron-beam-induced deposition (FEBID), a resist-free, nanofabrication compatible, direct-write method. The basic working principles of a computer-aided design (CAD) program (3BID) enabling 3D-FEBID is presented and simultaneously released for download. The 3BID capability significantly expands the currently limited toolbox for 3D-nanoprinting, providing access to geometries for optoelectronic, plasmonic, and nanomagnetic applications that were previously unattainable due to the lack of a suitable method for synthesis. In conclusion, the CAD approach supplants trial and error toward more precise/accurate FEBID requiredmore » for real applications/device prototyping.« less

  13. High-Fidelity 3D-Nanoprinting via Focused Electron Beams: Computer-Aided Design (3BID)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowlkes, Jason D.; Winkler, Robert; Lewis, Brett B.

    Currently, there are few techniques that allow true 3D-printing on the nanoscale. The most promising candidate to fill this void is focused electron-beam-induced deposition (FEBID), a resist-free, nanofabrication compatible, direct-write method. The basic working principles of a computer-aided design (CAD) program (3BID) enabling 3D-FEBID is presented and simultaneously released for download. The 3BID capability significantly expands the currently limited toolbox for 3D-nanoprinting, providing access to geometries for optoelectronic, plasmonic, and nanomagnetic applications that were previously unattainable due to the lack of a suitable method for synthesis. In conclusion, the CAD approach supplants trial and error toward more precise/accurate FEBID requiredmore » for real applications/device prototyping.« less

  14. How precise can atoms of a nanocluster be located in 3D using a tilt series of scanning transmission electron microscopy images?

    PubMed

    Alania, M; De Backer, A; Lobato, I; Krause, F F; Van Dyck, D; Rosenauer, A; Van Aert, S

    2017-10-01

    In this paper, we investigate how precise atoms of a small nanocluster can ultimately be located in three dimensions (3D) from a tilt series of images acquired using annular dark field (ADF) scanning transmission electron microscopy (STEM). Therefore, we derive an expression for the statistical precision with which the 3D atomic position coordinates can be estimated in a quantitative analysis. Evaluating this statistical precision as a function of the microscope settings also allows us to derive the optimal experimental design. In this manner, the optimal angular tilt range, required electron dose, optimal detector angles, and number of projection images can be determined. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Injectable 3-D Fabrication of Medical Electronics at the Target Biological Tissues

    NASA Astrophysics Data System (ADS)

    Jin, Chao; Zhang, Jie; Li, Xiaokang; Yang, Xueyao; Li, Jingjing; Liu, Jing

    2013-12-01

    Conventional transplantable biomedical devices generally request sophisticated surgery which however often causes big trauma and serious pain to the patients. Here, we show an alternative way of directly making three-dimensional (3-D) medical electronics inside the biological body through sequential injections of biocompatible packaging material and liquid metal ink. As the most typical electronics, a variety of medical electrodes with different embedded structures were demonstrated to be easily formed at the target tissues. Conceptual in vitro experiments provide strong evidences for the excellent performances of the injectable electrodes. Further in vivo animal experiments disclosed that the formed electrode could serve as both highly efficient ECG (Electrocardiograph) electrode and stimulator electrode. These findings clarified the unique features and practicability of the liquid metal based injectable 3-D fabrication of medical electronics. The present strategy opens the way for directly manufacturing electrophysiological sensors or therapeutic devices in situ via a truly minimally invasive approach.

  16. Evolutionary computation applied to the reconstruction of 3-D surface topography in the SEM.

    PubMed

    Kodama, Tetsuji; Li, Xiaoyuan; Nakahira, Kenji; Ito, Dai

    2005-10-01

    A genetic algorithm has been applied to the line profile reconstruction from the signals of the standard secondary electron (SE) and/or backscattered electron detectors in a scanning electron microscope. This method solves the topographical surface reconstruction problem as one of combinatorial optimization. To extend this optimization approach for three-dimensional (3-D) surface topography, this paper considers the use of a string coding where a 3-D surface topography is represented by a set of coordinates of vertices. We introduce the Delaunay triangulation, which attains the minimum roughness for any set of height data to capture the fundamental features of the surface being probed by an electron beam. With this coding, the strings are processed with a class of hybrid optimization algorithms that combine genetic algorithms and simulated annealing algorithms. Experimental results on SE images are presented.

  17. An investigation of the ionospheric D region at sunrise

    NASA Technical Reports Server (NTRS)

    Turco, R. P.; Sechrist, C. F., Jr.

    1970-01-01

    The growth over sunrise of the C and D layers of the ionosphere is investigated. The model which is analyzed includes the negative ion species O(-), O2(-), O3(-), O4(-), NO3(-), CO3(-), and CO4(-). Ionization sources due to galactic cosmic rays, precipitated electrons, ionization of NO by scattered Lyman alpha radiation, and the direct solar radiation ionization are also included. The photodetachment of most of the negative ions is discussed, as well as the time variation of these parameters. The time variations of the electron, negative ion, and positive ion densities are calculated over sunrise. From these data, the mesospheric C and D layer development is plotted. Several model parameters are varied until the best agreement with experimentally determined electron densities is obtained. The results are discussed in light of several atmospheric parameters including the O and NO concentrations and the electron-ion recombination coefficient.

  18. A Study on AR 3D Objects Shading Method Using Electronic Compass Sensor

    NASA Astrophysics Data System (ADS)

    Jung, Sungmo; Kim, Seoksoo

    More effective communications can be offered to users by applying NPR (Non-Photorealistic Rendering) methods to 3D graphics. Thus, there has been much research on how to apply NPR to mobile contents. However, previous studies only propose cartoon rendering for pre-treatment with no consideration for directions of light in the surrounding environment. In this study, therefore, ECS(Electronic Compass Sensor) is applied to AR 3D objects shading in order to define directions of light as per time slots for assimilation with the surrounding environment.

  19. A low-cost 3-D printed stethoscope connected to a smartphone.

    PubMed

    Aguilera-Astudillo, Carlos; Chavez-Campos, Marx; Gonzalez-Suarez, Alan; Garcia-Cordero, Jose L

    2016-08-01

    We demonstrate the fabrication of a digital stethoscope using a 3D printer and commercial off-the-shelf electronics. A chestpiece consists of an electret microphone embedded into the drum of a 3D printed chestpiece. An electronic dongle amplifies the signal from the microphone and reduces any external noise. It also adjusts the signal to the voltages accepted by the smartphones headset jack. A graphical user interface programmed in Android displays the signals processed by the dongle. The application also saves the processed signal and sends it to a physician.

  20. Electronic properties of GdxBi2-xSe3 single crystals analyzed by Shubnikov-de Haas oscillations

    NASA Astrophysics Data System (ADS)

    Kim, Soo-Whan; Jung, Myung-Hwa

    2018-05-01

    Magnetically doped topological insulators have been significantly researched for unlocking the nontrivial topological phases and the resultant potential applications for spintronics. We report the effect of antiferromagnetic order induced by Gd substitution on the electronic properties of GdxBi2-xSe3 single crystals by analyzing the Shubnikov-de Haas oscillations. Antiferromagnetic order of Gd ions affects the 2D surface state in Bi2Se3 and changes the effective mass and lifetime of charge carriers. These observations suggest a strong correlation of 2D surface electrons with the antiferromagnetic ordering, where the itinerant electrons are bound to the Gd ions to mediate the antiferromagnetic interaction.

Top