NASA Astrophysics Data System (ADS)
Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya; Momose, Takumaro
A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi nuclear power plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates >100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides Hp(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes.
Eakins, J S; Bartlett, D T; Hager, L G; Molinos-Solsona, C; Tanner, R J
2008-01-01
The Health Protection Agency is changing from using detectors made from 7LiF:Mg,Ti in its photon/electron personal dosemeters, to 7LiF:Mg,Cu,P. Specifically, the Harshaw TLD-700H card is to be adopted. As a consequence of this change, the dosemeter holder is also being modified not only to accommodate the shape of the new card, but also to optimize the photon and electron response characteristics of the device. This redesign process was achieved using MCNP-4C2 and the kerma approximation, electron range/energy tables with additional electron transport calculations, and experimental validation, with different potential filters compared; the optimum filter studied was a polytetrafluoroethylene disc of diameter 18 mm and thickness 4.3 mm. Calculated relative response characteristics at different angles of incidence and energies between 16 and 6174 keV are presented for this new dosemeter configuration and compared with measured type-test results. A new estimate for the energy-dependent relative light conversion efficiency appropriate to the 7LiF:Mg,Cu,P was also derived for determining the correct dosemeter response.
Type testing of the Siemens Plessey electronic personal dosemeter.
Hirning, C R; Yuen, P S
1995-07-01
This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.
Response of dosemeters in the radiation field generated by a TW-class laser system.
Olšovcová, V; Klír, D; Krása, J; Krůs, M; Velyhan, A; Zelenka, Z; Rus, B
2014-10-01
State-of-the-art laser systems are able to generate ionising radiation of significantly high energies by focusing ultra-short and intense pulses onto targets. Thus, measures ensuring the radiation protection of both working personnel and the general public are required. However, commercially available dosemeters are primarily designed for measurement in continuous fields. Therefore, it is important to explore their response to very short pulses. In this study, the responses of dosemeters in a radiation field generated by iodine high-power and Ti:Sapphire laser systems are examined in proton and electron acceleration experiments. Within these experiments, electron bunches of femtosecond pulse duration and 100-MeV energy and proton bunches with sub-nanosecond pulse duration and energy of several megaelectronvolts were generated in single-shot regimes. Responses of typical detectors (TLD, films and electronic personal dosemeter) were analysed and compared. Further, a first attempt was carried out to characterise the radiation field generated by TW-class laser systems. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Novel reference radiation fields for pulsed photon radiation installed at PTB.
Klammer, J; Roth, J; Hupe, O
2012-09-01
Currently, ∼70 % of the occupationally exposed persons in Germany are working in pulsed radiation fields, mainly in the medical sector. It has been known for a few years that active electronic dosemeters exhibit considerable deficits or can even fail completely in pulsed fields. Type test requirements for dosemeters exist only for continuous radiation. Owing to the need of a reference field for pulsed photon radiation and accordingly to the upcoming type test requirements for dosemeters in pulsed radiation, the Physikalisch-Technische Bundesanstalt has developed a novel X-ray reference field for pulsed photon radiation in cooperation with a manufacturer. This reference field, geared to the main applications in the field of medicine, has been well characterised and is now available for research and type testing of dosemeters in pulsed photon radiation.
Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters†.
Sanchez, R M; Vano, E; Fernandez, J M; Ginjaume, M; Duch, M A
2014-12-01
The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of -15 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was -9 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lahaye, T; Chau, Q; Ménard, S; Lacoste, V; Muller, H; Luszik-Bhadra, M; Reginatto, M; Bruguier, P
2006-01-01
This paper mainly aims at presenting the measurements and the results obtained with the electronic personal neutron dosemeter Saphydose-N at different facilities. Three campaigns were led in the frame of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). The first one consisted in the measurements at the IRSN French research laboratory in reference neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources ((241)AmBe; (252)Cf; (252)Cf(D(2)O)\\Cd) and a realistic spectrum (CANEL/T400). The second one was performed at the Krümmel Nuclear Power Plant (Germany) close to the boiling water reactor and to a spent fuel transport cask. The third one was realised at Mol (Belgium), at the VENUS Research Reactor and at Belgonucléaire, a fuel processing factory.
Kopeć, Renata; Bubak, Anna; Budzanowski, Maciej; Sas-Bieniarz, Anna; Szumska, Agnieszka
2016-09-01
Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used. The effects of medical sterilisation procedures were studied: by chemicals, by steam or by ultraviolet (UV), on the dose assessment by extremity rings and by eye lens dosemeters. Since it often happens that a dosemeter is accidentally machine-washed together with protective clothing, the effect of laundering on dose assessment by these dosemeters was also tested. The sterilisation by chemicals is mostly safe for TL detectors assuming that the dosemeters are waterproofed. Following sterilisation by water vapour, the response of these dosemeters diminished by some 30 %, irrespectively of the period of sterilisation; therefore, this method is not recommended. UV sterilisation can be applied to EYE-D™ eye lens dosemeters if their encapsulation is in black. The accidental dosemeter laundry in a washing machine has no impact on measured dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Vano, E; Sanchez, R M; Fernandez, J M
2015-07-01
The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 µSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm(2), respectively. The median ratios for dosemeters worn over the apron by operators (protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 µSv Gy(-1) cm(-2), respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y(-1) and per operator were necessary to reach the new lens dose limit for the three interventional specialties. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Albedo Neutron Dosimetry in a Deep Geological Disposal Repository for High-Level Nuclear Waste.
Pang, Bo; Becker, Frank
2017-04-28
Albedo neutron dosemeter is the German official personal neutron dosemeter in mixed radiation fields where neutrons contribute to personal dose. In deep geological repositories for high-level nuclear waste, where neutrons can dominate the radiation field, it is of interest to investigate the performance of albedo neutron dosemeter in such facilities. In this study, the deep geological repository is represented by a shielding cask loaded with spent nuclear fuel placed inside a rock salt emplacement drift. Due to the backscattering of neutrons in the drift, issues concerning calibration of the dosemeter arise. Field-specific calibration of the albedo neutron dosemeter was hence performed with Monte Carlo simulations. In order to assess the applicability of the albedo neutron dosemeter in a deep geological repository over a long time scale, spent nuclear fuel with different ages of 50, 100 and 500 years were investigated. It was found out, that the neutron radiation field in a deep geological repository can be assigned to the application area 'N1' of the albedo neutron dosemeter, which is typical in reactors and accelerators with heavy shielding. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Mayer, Sabine; Boschung, Markus; Butterweck, Gernot; Assenmacher, Frank; Hohmann, Eike
2016-09-01
Since 2008 the Paul Scherrer Institute (PSI) has been using a microscope-based automatic scanning system for assessing personal neutron doses with a dosemeter based on PADC. This scanning system, known as TASLImage, includes a comprehensive characterisation of tracks. The distributions of several specific track characteristics such as size, shape and optical density are compared with a reference set to discriminate tracks of alpha particles and non-track background. Due to the dosemeter design at PSI, it is anticipated that radon should not significantly contribute to the creation of additional tracks in the PADC detector. The present study tests the stability of the neutron dose determination algorithm of the personal neutron dosemeter system in operation at PSI at different radon gas exposures. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Boschung, M; Fiechtner, A; Wernli, C
2007-01-01
In the framework of the EVIDOS project, funded by the EC, measurements were carried out using dosemeters, based on ionisation chambers with direct ion storage (DIS-N), at several workplace fields, namely, at a fuel processing plant, a boiling and a pressurised water reactor, and near transport and storage casks. The measurements and results obtained with the DIS-N in these workplaces, which are representative for the nuclear industry, are described in this study. Different dosemeter configurations of converter and shielding materials were considered. The results are compared with values for personal dose equivalent which were assessed within the EVIDOS project by other partners. The advantages and limitations of the DIS-N dosemeter are discussed.
Energy dependence of lithium fluoride dosemeter for high energy electrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antoku, S.; Sunayashiki, T.; Takeoka, S.
1973-11-01
A lithium fluoride and a Fricke dosemeter have been exposed simultaneously to /sup 60/Co gamma -rays and 10, 20, and 30 MeV electrons to study the energy dependence of the lithium fluoride dosemeter for high-energy electrons, with particular reference to possible significant reductions in the sensitivity of LiF phosphors for electrons as compared with /sup 60/Co gamma - rays. In the present study, the direct comparison excluded errors resulting from uncertainties about ion recombination and conversion factors from roentgens to rads for ionization chambers. The dosemeters were exposed to approximately 5000 rads of each radiation at the appropriate peak depthmore » in a water phantom. Corrections for the supra-linear response for LiF were made using a dose response curve for /sup 60/Co gamma -rays. The three types of LiF phosphor examined did not exhibit any energy dependence for electrons compared with /sup 60/Co gamma - rays. Within the statistical uncertainty (~3%) for the experiment. (UK)« less
CORRECTIONS ASSOCIATED WITH ON-PHANTOM CALIBRATIONS OF NEUTRON PERSONAL DOSEMETERS.
Hawkes, N P; Thomas, D J; Taylor, G C
2016-09-01
The response of neutron personal dosemeters as a function of neutron energy and angle of incidence is typically measured by mounting the dosemeters on a slab phantom and exposing them to neutrons from an accelerator-based or radionuclide source. The phantom is placed close to the source (75 cm) so that the effect of scattered neutrons is negligible. It is usual to mount several dosemeters on the phantom together. Because the source is close, the source distance and the neutron incidence angle vary significantly over the phantom face, and each dosemeter may receive a different dose equivalent. This is particularly important when the phantom is angled away from normal incidence. With accelerator-produced neutrons, the neutron energy and fluence vary with emission angle relative to the charged particle beam that produces the neutrons, contributing further to differences in dose equivalent, particularly when the phantom is located at other than the straight-ahead position (0° to the beam). Corrections for these effects are quantified and discussed in this article. © Crown copyright 2015.
FIELD CALIBRATION OF A TLD ALBEDO DOSEMETER IN THE HIGH-ENERGY NEUTRON FIELD OF CERF.
Haninger, T; Kleinau, P; Haninger, S
2017-04-28
The new albedo dosemeter-type AWST-TL-GD 04 has been calibrated in the CERF neutron field (Cern-EU high-energy Reference Field). This type of albedo dosemeter is based on thermoluminescent detectors (TLDs) and used by the individual monitoring service of the Helmholtz Zentrum München (AWST) since 2015 for monitoring persons, who are exposed occupationally against photon and neutron radiation. The motivation for this experiment was to gain a field specific neutron correction factor Nn for workplaces at high-energy particle accelerators. Nn is a dimensionless factor relative to a basic detector calibration with 137Cs and is used to calculate the personal neutron dose in terms of Hp(10) from the neutron albedo signal. The results show that the sensitivity of the albedo dosemeter for this specific neutron field is not significantly lower as for fast neutrons of a radionuclide source like 252Cf. The neutron correction factor varies between 0.73 and 1.16 with a midrange value of 0.94. The albedo dosemeter is therefore appropriate to monitor persons, which are exposed at high-energy particle accelerators. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Beerten, Koen; Vanhavere, Filip
2010-08-01
New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to (60)Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity.
Accuracy of megavolt radiation dosimetry using thermoluminescent lithium fluoride.
Rudén, B I; Bengtsson, L G
1977-04-01
The relative light output per Gy in polystyrene for roentgen beams of 6 and 42 MV and electrons between 2.2 and 34.5 MeV relative to 60Co gamma radiation is reported for different kinds of LiF dosemeters. The distribution of the absorbed dose inside a 0.25 and 0.4 mm thick LiF-teflon disc surrounded by polystyrene and irradiated with 60Co, 42 MV roentgen radiation and 39 MeV electrons was measured using 0.01 and 0.02 mm thick Lif-teflon discs. The measurements show that the absorbed dose distribution in the dosemeter depends on the energy of the radiation. When flat dosemeters were used, differences between the signals measured at the two orientations possible during read-out could easily amount to several per cent, and for this reason 0.4 mm and 0.5 mm LiF-Teflon discs were not trusted when the highest accuracy was required. The cavity theory by Burlin does not account for the phenomena caused by differences in electron scattering properties of the dosemeter and the phantom material. Some suggestions are presented for a different cavity theory for flat dosemeters dealing also with these phenomena. It describes the results to about the same degree of approximation as the Burlin theory, and fails to explain the observed energy dependence for electrons.
NASA Astrophysics Data System (ADS)
Szumska, A.; Budzanowski, M.; Kopeć, R.
2017-11-01
In its statement on tissue reactions approved on 21st April 2011, the International Commission on Radiological Protection (ICRP, 2012) reviewed its recommendation concerning the equivalent dose limit for the eye lens and reduced the dose limits for occupationally exposed persons to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. This limit was approved and written down in the new EURATOM (European Atomic Energy Community) directive 2013/59 and in the IAEA (International Atomic Energy Agency) BSS (Basic Safety Standard) of July 2014. For that reason, the necessity to monitor the eye lens may become more important than it was before. However, specially dedicated dosemeters for the dose quantity Hp(3) are using very rarely. Commonly use are only whole body personal dosemeters for the personal dose equivalent quantities Hp(10) worn on the trunk and ring dosemeters worn on finger to measure the quantity Hp(0.07). Therefore, in this work it was investigated whether dosemeters from routine use calibrated in terms of Hp(10) and Hp(0.07) and worn on thyroid collar and protective apron could deliver similar results like dedicated eye lens dosemeter worn close to the eyes. The results show that the best method if dedicated eye lens dosimeters is not used is to measure doses in terms of Hp(0.07) on the thyroid collar (Pearson product, r=0.85). Obtained results shows also importance of proper localization of eye lens dosimeter (close to the eye, from side of the X-ray source).
Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M
2002-01-01
The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.
Zeyrek, C T; Gündüz, H
2012-09-01
This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together.
Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.
Becková, Vera; Malátová, Irena
2008-01-01
Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h(-1) and the sampling period is typically 1 month. Studied filters contained 125 +/- 6 mBq (238)U in equilibrium with (234)U and (230)Th; no (232)Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for (238)U and (234)U and slow dissolution half-times of 173 and 116 d were found for (238)U and (234)U, respectively. No detectable dissolution of (230)Th was found.
ASSESSMENT OF EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY: A SIMULATION IN LABORATORY CONDITIONS.
Čemusová, Z; Ekendahl, D; Judas, L
2016-09-01
As workers in interventional radiology belong to one of the most occupationally exposed groups, methods for sufficiently accurate quantification of their external exposure are sought. The objective of the authors' experiment was to investigate the relations between eye lens dose and Hp(10), Hp(3) or Hp(0.07) values measured with a conventional whole-body personal thermoluminescence dosemeter (TLD). Conditions of occupational exposure during common interventional procedures were simulated in laboratory. An anthropomorphic phantom represented a physician. The TLDs were fixed to the phantom in different locations that are common for purposes of personal dosimetry. In order to monitor the dose at the eye lens level during the exposures, a special thermoluminescence eye dosemeter was fixed to the phantom's temple. Correlations between doses measured with the whole-body and the eye dosemeters were found. There are indications that personnel in interventional radiology do not need to be unconditionally equipped with additional eye dosemeters, especially if an appropriate whole-body dosimetry system has been already put into practice. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Investigation of a BeO-based optically stimulated luminescence dosemeter.
Sommer, M; Henniger, J
2006-01-01
The optical sensitivity of BeO-based luminophors has been well-known for many years. The optical stimulation of BeO with blue light is most effective. Then the dosemeters emit luminescent light in the ultraviolet-range around 325 nm. Matched on these facts a simple optically stimulated luminescence (OSL) treatment has been developed. Intense blue light-emitting diodes are used for cw-stimulation. A Hamamatsu solar blind photomultiplier detects the OSL-light. Good separation of both spectral ranges by optical filters is very important. The dosemeter has a linear dose response between approximately 20 muGy and >10 Gy. It was suggested, that a modification of stimulation conditions would allow measurements down to 1 muGy. Fading, photon energy dependence and reproducibility of OSL-signal correspond well with requirements to clinical and personal dosemeters. In addition, basic questions of the OSL-process in BeO have been investigated. A relevant point of interest was the dependency of the OSL-signal on stimulation power.
Assessment of neutron dosemeters around standard sources and nuclear fissile objects.
Raimondi, N; Tournier, B; Groetz, J E; Piot, J; Riebler, E; Crovisier, P; Chambaudet, A; Cabanné, N
2002-01-01
In order to evaluate the neutron doses around nuclear fissile objects, a comparative study has been made on several neutron dosemeters: bubble dosemeters, etched-track detectors (CR-39) and 3He-filled proportional counters used as dose-rate meters. The measurements were made on the ambient and the personal dose equivalents H*(10) and Hp(10). Results showed that several bubble dosemeters should have been used due to a low reproducibility in the measurements. A strong correlation with the neutron energy was also found, with about a 30% underestimation of Hp(10) for neutrons from the PuBe source, and about a 9% overestimation for neutrons from the 252Cf source. Measurements of the nuclear fissile objects were made using the CR-39 and the dose-rate meters. The CR-39 led to an underestimation of 30% with respect to the neutron dose-rate meter measurements. In addition, the MCNP calculation code was used in the different configurations.
Czech results at criticality dosimetry intercomparison 2002.
Frantisek, Spurný; Jaroslav, Trousil
2004-01-01
Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV.
Application of whole-body personal TL dosemeters in mixed field beta-gamma radiation.
Ciupek, K; Aksamit, D; Wołoszczuk, K
2014-11-01
Application of whole-body personal TL dosemeters based on a high-sensitivity LiF:Mg,Cu,P (MCP-N) in mixed field beta-gamma radiation has been characterised. The measurements were carried out with (90)Sr/(90)Y, (85)Kr and (137)Cs point sources to calculate the energy response and linearity of the TLD response in a dose range of 0.1-30 mSv. From the result, calibration curves were obtained, enabling the readout of individual dose equivalent Hp(10) from gamma radiation and Hp(0.07) from beta radiation in mixed field beta-gamma. Limitation of the methodology and its application are presented and discussed. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A new paradigm in personal dosimetry using LiF:Mg,Cu,P.
Cassata, J R; Moscovitch, M; Rotunda, J E; Velbeck, K J
2002-01-01
The United States Navy has been monitoring personnel for occupational exposure to ionising radiation since 1947. Film was exclusively used until 1973 when thermoluminescence dosemeters were introduced and used to the present time. In 1994, a joint research project between the Naval Dosimetry Center, Georgetown University, and Saint Gobain Crystals and Detectors (formerly Bicron RMP formerly Harshaw TLD) began to develop a state of the art thermoluminescent dosimetry system. The study was conducted from a large-scale dosimetry processor point of view with emphasis on a systems approach. Significant improvements were achieved by replacing the LiF:Mg,Ti with LiF:Mg,Cu,P TL elements due to the significant sensitivity increase, linearity, and negligible hiding. Dosemeter filters were optimised for gamma and X ray energy discrimination using Monte Carlo modelling (MCNP) resulting in significant improvement in accuracy and precision. Further improvements were achieved through the use of neural-network based dose calculation algorithms. Both back propagation and functional link methods were implemented and the data compared with essentially the same results. Several operational aspects of the system are discussed, including (1) background subtraction using control dosemeters, (2) selection criteria for control dosemeters, (3) optimisation of the TLD readers, (4) calibration methodology, and (5) the optimisation of the heating profile.
Srivastava, Kshama; Soin, Seepika; Sapra, B K; Ratna, P; Datta, D
2017-11-01
The occupational exposure incurred by the radiation workers due to the external radiation is estimated using personal dosemeter placed on the human body during the monitoring period. In certain situations, it is required to determine whether the dosemeter alone was exposed accidentally/intentionally in radiation field (static exposure) or was exposed while being worn by a worker moving in his workplace (dynamic exposure). The present thermoluminscent (TL) based personnel monitoring systems are not capable of distinguishing between the above stated (static and dynamic) exposure conditions. The feasibility of a new methodology developed using the charge coupled device based imaging technique for identification of the static/dynamic exposure of CaSO4:Dy based TL detectors for low energy photons has been investigated. The techniques for the qualitative and the quantitative assessments of the exposure conditions are presented in this paper. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Rizk, C; Vanhavere, F
2016-09-01
The personal dosimetry service at the Lebanese Atomic Energy Commission uses Harshaw 8814 cards with LiF:Mg,Ti detectors. The dosemeters are read in a Harshaw 6600 TLD reader. In the process of accreditation for the ISO 17025 standard((1)), different influence factors are investigated and the uncertainty has been determined. The Individual Monitoring Service Laboratory-LAEC reads the dosemeters once it receives them from the customer, and new cards are immediately given for the next wearing period. The wearing period is 2 months. The dosemeter results are reported to the customers without background subtraction. Both Hp(10) and Hp(0.07) are reported. For this paper, only the uncertainty on Hp(10) will be focussed. The following factors are taken into account for the uncertainty: calibration factor, dosemeter homogeneity and repeatability, energy and angular dependence, non-linearity, temperature dependence, etc. Also the detection limit was determined. One of the important factors is the correction for fading. This fading correction depends on the procedure used such as storage temperatures, the time-temperature profile of the read-out, pre-heat and annealing conditions. Pre- and post-irradiation fading curves were measured for a storage period up to 182 d at room temperature (15-25°C). The resulting final combined standard uncertainty on the reported doses is of the order of 24 % for doses of ∼1 mSv. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
GENERALISATION OF RADIATOR DESIGN TECHNIQUES FOR PERSONAL NEUTRON DOSEMETERS BY UNFOLDING METHOD.
Oda, K; Nakayama, T; Umetani, K; Kajihara, M; Yamauchi, T
2016-09-01
A novel technique for designing a radiator suitable for personal neutron dosemeter based on plastic track detector was discussed. A multi-layer structure has been proposed in the previous report, where the thicknesses of plural polyethylene (PE) layers and insensitive ones were determined by iterative calculations of double integral. In order to arrange this procedure and make it more systematic, unfolding calculation has been employed to estimate an ideal radiator containing an arbitrary hydrogen concentration. In the second step, realistic materials replaced it with consideration of minimisation of the layer number and commercial availability. A radiator consisting of three layers of PE, Upilex and Kapton sheets was finally designed, for which a deviation in the energy dependence between 0.1 and 20 MeV could be controlled within 18 %. An applicability of fluorescent nuclear track detector element has also been discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
CHARACTERIZATION OF A THIN SILICON SENSOR FOR ACTIVE NEUTRON PERSONAL DOSEMETERS.
Takada, M; Nunomiya, T; Nakamura, T; Matsumoto, T; Masuda, A
2016-09-01
A thin silicon sensor has been developed for active neutron personal dosemeters for use by aircrews and first responders. This thin silicon sensor is not affected by the funneling effect, which causes detection of cosmic protons and over-response to cosmic neutrons. There are several advantages to the thin silicon sensor: a decrease in sensitivity to gamma rays, an improvement of the energy detection limit for neutrons down to 0.8 MeV and an increase in the sensitivity to fast neutrons. Neutron response functions were experimentally obtained using 2.5 and 5 MeV monoenergy neutron beams and a (252)Cf neutron source. Simulation results using the Monte Carlo N-Particle transport code agree quite well with the experimental ones when an energy deposition region shaped like a circular truncated cone is used in place of a cylindrical region. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dose measurements in space by the Hungarian Pille TLD system.
Apathy, I; Deme, S; Feher, I; Akatov, Y A; Reitz, G; Arkhanguelski, V V
2002-10-01
Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 microGy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised. c2002 Elsevier Science Ltd. All rights reserved.
Magne, S; Auger, L; Bordy, J M; de Carlan, L; Isambert, A; Bridier, A; Ferdinand, P; Barthe, J
2008-01-01
This article proposes an innovative multichannel optically stimulated luminescence (OSL) dosemeter for on-line in vivo dose verification in radiation therapy. OSL fibre sensors incorporating small Al(2)O(3):C fibre crystals (TLD(500)) have been tested with an X-ray generator. A reproducible readout procedure should reduce the fading-induced uncertainty ( approximately - 1% per decade). OSL readouts are temperature-dependent [ approximately 0.3% K(-1) when OSL stimulation is performed at the same temperature as irradiation; approximately 0.16% K(-1) after thermalisation (20 degrees C)]. Sensor calibration and depth-dose measurements with electron beams have been performed with a Saturne 43 linear accelerator in reference conditions at CEA-LNHB (ionising radiation reference laboratory in France). Predosed OSL sensors show a good repeatability in multichannel operation and independence versus electron energy in the range (9, 18 MeV). The difference between absorbed doses measured by OSL and an ionisation chamber were within +/-0.9% (for a dose of about 1 Gy) despite a sublinear calibration curve.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voytchev, Miroslav; Ambrosi, P.; Behrens, R.
This paper presents IEC/SC 45B Radiation protection instrumentation and its standards for individual monitoring of ionising radiation: IEC 61526 Ed. 3 for active personal dosemeters and IEC 62387-1 for passive integrating dosimetry systems. The transposition of these standards as CENELEC (European) standards is also discussed together with the collaboration between IEC/SC 45B and ISO/TC 85/SC 2.
An environmental-level, real-time, pulsed photon dosemeter.
Olsher, R H; Frymire, A; Gregoire, T
2005-01-01
Radiation sources producing short pulses of photon radiation are widespread. Such sources include electron linear accelerators and field emission impulse generators. It is often desirable to measure leakage and skyshine radiation for these sources in real time and at environmental levels as low as 0.02 microSv per pulse. This note provides an overview of the design and performance of a commercial, real-time, pulsed photon dosemeter (PPD) capable of single-pulse dose measurements over the range from 0.02 to 20 microSv. The PPD may also be operated in a multiple-pulse mode that integrates the dose from a train of pulses over a 3 s period. A pulse repetition rate of up to 300 Hz is accommodated.
Self-indicating radiation alert dosemeter (SIRAD).
Riel, Gordon K; Winters, Patrick; Patel, Gordhan; Patel, Paresh
2006-01-01
In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by <1% per degrees C from -20 to +60 degrees C. The shelf-life is >3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident.
Thierry-Chef, I; Pernicka, F; Marshall, M; Cardis, E; Andreo, P
2002-01-01
An international collaborative study of cancer risk among workers in the nuclear industry is tinder way to estimate direetly the cancer risk following protracted low-dose exposure to ionising radiation. An essential aspect of this study is the characterisation and quantification of errors in available dose estimates. One major source of errors is dosemeter response in workplace exposure conditions. Little information is available on energy and geometry response for most of the 124 different dosemeters used historically in participating facilities. Experiments were therefore set up to assess this. using 10 dosemeter types representative of those used over time. Results show that the largest errors were associated with the response of early dosemeters to low-energy photon radiation. Good response was found with modern dosemeters. even at low energy. These results are being used to estimate errors in the response for each dosemeter type, used in the participating facilities, so that these can be taken into account in the estimates of cancer risk.
Popoca, R; Ureña-Núñez, F
2009-06-01
This work reports the possibility of using lithium carbonate as a dosimetric material for gamma-radiation measurements. Carboxi-radical ions, CO(2)(-) and CO(3)(-), arise from the gamma irradiation of Li(2)CO(3), and these radical ions can be quantified by electron paramagnetic resonance (EPR) spectrometry. The EPR-signal response of gamma-irradiated lithium carbonate has been investigated to determine some dosimetric characteristics such as: peak-to-peak signal intensity versus gamma dose received, zero-dose response, signal fading, signal repeatability, batch homogeneity, dose rate effect and stability at different environmental conditions. Using the conventional peak-to-peak method of stable ion radicals, it is concluded that lithium carbonate could be used as a gamma dosemeter in the range of 3-100 Gy.
Performance of Harshaw TLD-100H two-element Dosemeter.
Luo, L Z; Rotunda, J E
2006-01-01
One of the advantages of LiF based thermoluminescent (TL) materials is its tissue-equivalent property. The Harshaw TLD-100H (LiF:Mg,Cu,P) material has demonstrated that it has a near-flat photon energy response and high sensitivity. With the optimized dosemeter filters built into the holder, the Harshaw TLD-100H two-element dosemeter can be used as a whole body personnel dosemeter for gamma, X ray and beta monitoring without the use of an algorithm or correction factor. This paper presents the dose performance of the Harshaw TLD-100H two-element dosemeter against the ANSI N13.11-2001 standard and the results of tests that are required in IEC 1066 International Standard.
Endo, A; Katoh, T; Kobayashi, I; Joshi, R; Sur, J; Okano, T
2012-01-01
Objective The aim of this study was to assess the characteristics of an optically stimulated luminescence dosemeter (OSLD) for use in diagnostic radiology and to apply the OSLD in measuring the organ doses by panoramic radiography. Methods The dose linearity, energy dependency and angular dependency of aluminium oxide-based OSLDs were examined using an X-ray generator to simulate various exposure settings in diagnostic radiology. The organ doses were then measured by inserting the dosemeters into an anthropomorphic phantom while using three panoramic machines. Results The dosemeters demonstrated consistent dose linearity (coefficient of variation<1.5%) and no significant energy dependency (coefficient of variation<1.5%) under the applied exposure conditions. They also exhibited negligible angular dependency (≤10%). The organ doses of the X-ray as a result of panoramic imaging by three machines were calculated using the dosemeters. Conclusion OSLDs can be utilized to measure the organ doses in diagnostic radiology. The availability of these dosemeters in strip form proves to be reliably advantageous. PMID:22116136
Design of a finger ring extremity dosemeter based on OSL readout of alpha-Al2O3:C.
Durham, J S; Zhang, X; Payne, F; Akselrod, M S
2002-01-01
A finger-ring dosemeter and reader has been designed that uses OSL readout of alpha-Al2O3:C (aluminium oxide). The use of aluminium oxide is important because it allows the sensitive element of the dosemeter to be a very thin layer that reduces the beta and gamma energy dependence to acceptable levels without compromising the required sensitivity for dose measurement. OSL readout allows the ring dosemeter to be interrogated with minimal disassembly. The ring dosemeter consists of three components: aluminium oxide powder for measurement of dose, an aluminium substrate that gives structure to the ring, and an aluminised Mylar cover to prevent the aluminium oxide from exposure to light. The thicknesses of the three components have been optimised for beta response using the Monte Carlo computer code FLUKA. A reader was also designed and developed that allows the dosemeter to be read after removing the Mylar. Future efforts are discussed.
A comparison of personal dose equivalent measurements made by personal dosemeters
NASA Astrophysics Data System (ADS)
Cechak, T.; Davidkova, J.; Kodl, O.; Novacek, P.; Papirnik, P.; Petrova, K.; Prasek, P.; Martincik, J.; Sochor, V.
2014-11-01
Individual monitoring services for external radiation were tested in the Czech Republic. The results of the tests show that they are dosimetry systems authorized and regularly tested in the Czech Republic having outliers for low energy region and angle of 50 degree and greater. With the highest probability, it can be stated that the processing equipment does not determine the angle of exposure reliably. These cases may have caused overestimations of Hp(10) in the special conditions occurring e.g. in interventional radiology and cardiology procedures.
Manninen, A-L; Kotiaho, A; Nikkinen, J; Nieminen, M T
2015-04-01
This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior-posterior projection and the EDs were determined at posterior-anterior, anterior-posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies <60 and >80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chau, Q; Bruguier, P
2007-01-01
In nuclear facilities, some activities such as reprocessing, recycling and production of bare fuel rods expose the workers to mixed neutron-photon fields. For several workplaces, particularly in glove boxes, some workers expose their hands to mixed fields. The mastery of the photon extremity dosimetry is relatively good, whereas the neutron dosimetry still raises difficulties. In this context, the Institute for Radiological Protection and Nuclear Safety (IRSN) has proposed a study on a passive neutron extremity dosemeter based on chemically etched CR-39 (PADC: polyallyldiglycolcarbonate), named PN-3, already used in routine practice for whole body dosimetry. This dosemeter is a chip of plastic sensitive to recoil protons. The chemical etching process amplifies the size of the impact. The reading system for tracks counting is composed of a microscope, a video camera and an image analyser. This system is combined with the dose evaluation algorithm. The performance of the dosemeter PN-3 has been largely studied and proved by several laboratories in terms of passive individual neutron dosemeter which is used in routine production by different companies. This study focuses on the sensitivity of the extremity dosemeter, as well as its performance in the function of the level of the neutron energy. The dosemeter was exposed to monoenergetic neutron fields in laboratory conditions and to mixed fields in glove boxes at workplaces.
Monitoring the eye lens: which dose quantity is adequate?
NASA Astrophysics Data System (ADS)
Behrens, R.; Dietze, G.
2010-07-01
Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity Hp(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity Hp(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of Hp(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of Hp(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of Hp(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.
Monitoring the eye lens: which dose quantity is adequate?
Behrens, R; Dietze, G
2010-07-21
Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity H(p)(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity H(p)(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of H(p)(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of H(p)(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of H(p)(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.
Lee, YoungJu; Won, Yuho; Kang, Kidoo
2015-04-01
Passive integrating dosemeters [thermoluminescent dosimeter (TLD) and optically stimulated luminescence (OSL)] are the only legally permitted individual dosemeters for occupational external radiation exposure monitoring in Korea. Also its maximum issuing cycle does not exceed 3 months, and the Korean regulations require personal dosemeters for official assessment of external radiation exposure to be issued by an approved or rather an accredited dosimetry service according to ISO/IEC 17025. KHNP (Korea Hydro & Nuclear Power, LTD), a unique operating company of nuclear power plants (NPPs) in Korea, currently has a plan to extend a TLD issuing cycle from 1 to 3 months under the authors' fading error criteria, ±10%. The authors have performed a feasibility study that minimises post-irradiation fading effects within their maximum reading cycle employing pre-heating technique. They repeatedly performed irradiation/reading a bare TLD chip to determine optimum pre-heating conditions by analysing each glow curve. The optimum reading conditions within the maximum reading cycle of 3 months were decided: a pre-heating temperature of 165°C, a pre-heating time of 9 s, a heating rate of 25°C s(-1), a reading temperature of 300°C and an acquisition time of 10 s. The fading result of TLD-600 and TLD-700 carried by newly developed time temperature profile (TTP) showed a much smaller fading effect than that of current TTP. The result showed that the fading error due to a developed TTP resulted in a ∼5% signal loss, whereas a current TTP caused a ∼15% loss. The authors also carried out a legal performance test on newly developed TTP to confirm its possibility as an official dosemeter. The legal performance tests that applied the developed TTP satisfied the criteria for all the test categories. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
RADIATION PROTECTION CABIN FOR CATHETER-DIRECTED LIVER INTERVENTIONS: OPERATOR DOSE ASSESSMENT.
Maleux, Geert; Bergans, Niki; Bosmans, Hilde; Bogaerts, Ria
2016-09-01
The number and complexity of interventional radiological procedures and in particular catheter-directed liver interventions have increased substantially. The current study investigates the reduction of personal doses when using a dedicated radiation protection cabin (RPC) for these procedures. Operator and assistant doses were assessed for 3 series of 20 chemoinfusion/chemoembolisation interventions, including an equal number of procedures with and without RPC. Whole body doses, finger doses and doses at the level of knees and eyes were evaluated with different types of TLD-100 Harshaw dosemeters. Dosemeters were also attached on the three walls of the RPC. The operator doses were significantly reduced by the RPC, but also without RPC, the doses appear to be limited as a result of thorough optimisation with existing radiation protection tools. The added value of the RPC should thus be determined by the outcome of balancing dose reduction and other aspects such as ergonomic benefits. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Frelin-Labalme, Anne-Marie; Ledoux, Xavier
2017-01-01
Objective: Small animal image-guided irradiators have recently been developed to mimic the delivery techniques of clinical radiotherapy. A dosemeter adapted to millimetric beams of medium-energy X-rays is then required. This work presents the characterization of a dosemeter prototype for this particular application. Methods: A scintillating optical fibre dosemeter (called DosiRat) has been implemented to perform real-time dose measurements with the dedicated small animal X-RAD® 225Cx (Precision X-Ray, Inc., North Branford, CT) irradiator. Its sensitivity, stem effect, stability, linearity and measurement precision were determined in large field conditions for three different beam qualities, consistent with small animal irradiation and imaging parameters. Results: DosiRat demonstrates good sensitivity and stability; excellent air kerma and air kerma rate linearity; and a good repeatability for air kerma rates >1 mGy s−1. The stem effect was found to be negligible. DosiRat showed limited precision for low air kerma rate measurements (<1 mGy s−1), typically for imaging protocols. A positive energy dependence was found that can be accounted for by calibrating the dosemeter at the needed beam qualities. Conclusion: The dosimetric performances of DosiRat are very promising. Extensive studies of DosiRat energy dependence are still required. Further developments will allow to reduce the dosemeter size to ensure millimetric beams dosimetry and perform small animal in vivo dosimetry. Advances in knowledge: Among existing point dosemeters, very few are dedicated to both medium-energy X-rays and millimetric beams. Our work demonstrated that scintillating fibre dosemeters are suitable and promising tools for real-time dose measurements in the small animal field of interest. PMID:27556813
Using operational equipment to read accident dosemeters.
Devine, R T; Vigil, M M; Martinez, W A
2004-01-01
Analysis of accident dosemeters usually involves the use of laboratory-based counting equipment. Gamma spectrometers are used for indium, copper and gold, and alpha-beta detectors for sulphur. This equipment is usually not easily transported due to the shielding required and the weight and delicacy of the counters. For intercomparison studies that require reading the dosemeters on site, a transportable system is required unless the site operating the study can count samples for all the participants. In the case of an actual accident these systems would have a difficulty in counting a large number of accident dosemeters. In an accident, personnel are usually subdivided according to their level of exposure. Those exposed to higher doses are treated immediately. An alternate system should be made available to handle the dosemeters worn by those personnel are likely to receive lower doses. Improvements in portable operational equipment for gamma and beta monitoring allow their use as spectrometers. Such a system was used for the SILENE intercomparison conducted at IRSN Valduc on 12 June and 19, 2002, and the preliminary results compared well with the other participants.
The ENEA neutron personal dosimetry service.
Morelli, B; Mariotti, F; Fantuzzi, E
2006-01-01
The ENEA Radiation Protection Institute has been operating the only neutron personal dosimetry service in Italy since the 1970s. Since the 1980s the service has been based on PADC (poly allyl diglycol carbonate) for fast neutron dosimetry, while thermal neutron dosimetry has been performed using thermoluminescence (TL) dosemeters. Since the service was started, a number of aspects have undergone evolution. The latest and most important changes are as follows: in 1998 a new PADC material was introduced in routine, since 2001 TL thermal dosimetry has been based on LiF(Mg,Cu,P) [GR-200] and (7)LiF(Mg,Cu,P) [GR-207] detectors and since 2003 a new image analysis reading system for the fast neutron dosemeters has been used. Herein an updated summary of how the service operates and performs today is presented. The approaches to calibration and traceability to estimate the quantity of H(p)(10) are mentioned. Results obtained at the performance test of dosimetric services in the EU member states and Switzerland sponsored by the European Commission and organised by Eurados in 1999 are reported. Last but not least, quality assurance (QA) procedures introduced in the routine operation to track the whole process of dose evaluation (i.e. plastic QA, acceptance test, test etching bath reproducibility and 'dummy customer' (blind test) for each issuing monitoring period) are presented and discussed.
TL detectors for gamma ray dose measurements in criticality accidents.
Miljanić, Saveta; Zorko, Benjamin; Gregori, Beatriz; Knezević, Zeljka
2007-01-01
Determination of gamma ray dose in mixed neutron+gamma ray fields is still a demanding task. Dosemeters used for gamma ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e., on neutron spectra. Besides, it is necessary to take into account the energy dependence of dosemeter responses to gamma rays. In this work, several types of thermoluminescent detectors (TLD) placed in different holders used for gamma ray dose determination in the mixed fields were examined. Dosemeters were from three different institutions: Ruder Bosković Institute (RBI), Croatia, JoZef Stefan Institute (JSI), Slovenia and Autoridad Regulatoria Nuclear (ARN), Argentina. All dosemeters were irradiated during the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002. Three accidental scenarios were reproduced and in each irradiation the dosemeters were exposed placed on the front of phantom and 'free in air'. Following types of TLDs were used: 7LiF (TLD-700), CaF2:Mn and Al2O3:Mg,Y-all from RBI; CaF2:Mn from JSI and 7LiF (TLD-700) from ARN. Reported doses were compared with the reference values as well as with the values obtained from the results of all participants. The results show satisfactory agreement with other dosimetry systems used in the Intercomparison. The influence of different types of holders and applied corrections of dosemeters' readings are discussed.
Personal Dose Equivalent Conversion Coefficients For Photons To 1 GEV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veinot, K. G.; Hertel, N. E.
2010-09-27
The personal dose equivalent, H{sub p}(d), is the quantity recommended by the International Commission on Radiation Units and Measurements (ICRU) to be used as an approximation of the protection quantity Effective Dose when performing personal dosemeter calibrations. The personal dose equivalent can be defined for any location and depth within the body. Typically, the location of interest is the trunk where personal dosemeters are usually worn and in this instance a suitable approximation is a 30 cm X 30 cm X 15 cm slab-type phantom. For this condition the personal dose equivalent is denoted as H{sub p,slab}(d) and the depths,more » d, are taken to be 0.007 cm for non-penetrating and 1 cm for penetrating radiation. In operational radiation protection a third depth, 0.3 cm, is used to approximate the dose to the lens of the eye. A number of conversion coefficients for photons are available for incident energies up to several MeV, however, data to higher energies are limited. In this work conversion coefficients up to 1 GeV have been calculated for H{sub p,slab}(10) and H{sub p,slab}(3) using both the kerma approximation and by tracking secondary charged particles. For H{sub p}(0.07) the conversion coefficients were calculated, but only to 10 MeV due to computational limitations. Additionally, conversions from air kerma to H{sub p,slab}(d) have been determined and are reported. The conversion coefficients were determined for discrete incident energies, but analytical fits of the coefficients over the energy range are provided. Since the inclusion of air can influence the production of secondary charged particles incident on the face of the phantom conversion coefficients have been determined both in vacuo and with the source and slab immersed within a sphere in air. The conversion coefficients for the personal dose equivalent are compared to the appropriate protection quantity, calculated according to the recommendations of the latest International Commission on Radiological Protection (ICRP) guidance.« less
Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O'Connor, Una
2015-09-01
A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.
Koivisto, J; Schulze, D; Wolff, J; Rottke, D
2014-01-01
The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO(®) head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; -5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; -14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; -16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region.
Dose received by occupationally exposed workers at a nuclear medicine department
NASA Astrophysics Data System (ADS)
Ávila, O.; Sánchez-Uribe, N. A.; Rodríguez-Laguna, A.; Medina, L. A.; Estrada, E.; Buenfil, A. E.; Brandan, M. E.
2012-10-01
Personal Dose Equivalent (PDE) values were determined for occupational exposed workers (OEW) at the Nuclear Medicine Department (NMD) of "Instituto Nacional de Cancerología" (INCan), Mexico, using TLD-100 thermoluminescent dosemeters. OEW at NMD, INCan make use of radiopharmaceuticals for diagnosis and treatment of diseases. Radionuclides associated to a pharmaceutical compound used at this Department are 131I, 18F, 68Ga, 99mTc, 111In and 11C with main gamma emission energies between 140 and 511 keV. Dosemeter calibration was performed at the metrology department of "Instituto Nacional de Investigaciones Nucleares" (ININ), Mexico. Every occupational worker used dark containers with three dosimeters which were replaced monthly for a total of 5 periods. Additionally, control dosemeters were also placed at a site free of radioactive sources in order to determine the background radiation. Results were adjusted to find PDE/day and estimating annual PDE values in the range between 2 mSv (background) and 9 mSv. The mean annual value is 3.51 mSv and the standard deviation SD is 0.78 mSv. Four of the 16 OEW received annual doses higher than the average +1 SD (4.29 mSv). Results depend on OEW daily activities and were consistent for each OEW for the 5 studied periods as well as with PDE values reported by the firm that performs the monthly service. All obtained values are well within the established annual OEW dose limit stated in the "Reglamento General de Seguridad Radiológica", México (50 mSv), as well as within the lower limit recommended by the "International Commission on Radiation Protection" (ICRP), report no.60 (20 mSv). These results verify the adequate compliance of the NMD at INCan, Mexico with the norms given by the national regulatory commission.
Schulze, D; Wolff, J; Rottke, D
2014-01-01
Objectives: The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Methods: Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO® head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). Results: The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; −5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; −14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; −16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Conclusions: Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region. PMID:25143020
Fast neutron dosemeter using pixelated detector Timepix.
Bulanek, Boris; Ekendahl, Daniela; Prouza, Zdenek
2014-10-01
A Timepix detector covered with polyethylene convertors of different thicknesses is presented as a fast neutron real-time dosemeter. The application of different weighting factors in connection with the position of a signal in a Timepix detector enables one to obtain an energy-dependent signal equal to neutron dose equivalents. A simulation of a Timepix detector covered with polyethylene convertors using monoenergetic neutrons is presented. The experimental set-up of a dosemeter was also produced. The first results of detector response using different fast neutron sources are presented. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Time dependence of the radiation-induced EPR signal in sucrose.
Desrosiers, Marc; Wadley, Samara
2006-01-01
Sucrose and common household sugars (e.g. cane) have been studied as dosemeters for a wide variety of applications. However, previous studies of the post-irradiation time dependence of irradiated sugar did not include an electron paramagnetic resonance (EPR) reference material. This work employs synthetic ruby as an EPR reference material to remove significant spectrometer/environmental influences on the measured time-dependent changes in the EPR spectral amplitude of irradiated sucrose. As such, these more accurate measurements should replace the previously published data.
Osvay, M; Deme, S
2006-01-01
Al2O3:Mg,Y ceramic thermoluminescence dosemeters were developed at the Institute of Isotopes for high dose applications at room temperatures. The glow curve of Al2O3:Mg,Y exhibits two peaks--one at 250 degrees C (I) and another peak at approximately 400 degrees C (II). In order to extend the application of these dosemeters to high temperatures, the effect of irradiation temperature was investigated using temperature controlled heating system during high dose irradiation at various temperatures (20-100 degrees C). The new calibration and measuring method has been successfully applied for dose mapping within the hermetic zone of the Paks Nuclear Power Plant even at high temperature parts of blocks.
Calibration of an eye lens dosemeter in terms of Hp(3) to be used in interventional radiology
NASA Astrophysics Data System (ADS)
Borges, F. L. S.; Guimarães, M. C.; Da Silva, T. A.; Nogueira Tavares, M. S.
2014-11-01
Recently, the International Commission on Radiological Protection has reviewed epidemiological evidences suggesting that there were tissue reaction effects in the eye lens below the previously considered absorbed dose threshold. A new statement related to the eye lens was issued that changed the absorbed dose threshold and reduced the dose limits for occupationally exposed persons. As consequence, some planned exposures require eye lens dosimetry and a debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to study the methodology for calibrating the EYE-DTM holder with a TLD-100H Harshaw chip detector and to determine its angular and energy dependences in terms of personal dose equivalent, Hp(3).
Principi, Sara; Ginjaume, Mercè; Duch, Maria Amor; Sánchez, Roberto M; Fernández, Jose M; Vano, Eliseo
2015-04-01
The equivalent dose limit for the eye lens for occupational exposure recommended by the ICRP has been reduced to 20 mSv y(-1) averaged over defined periods of 5 y, with no single year exceeding 50 mSv. The compliance with this new requirement could not be easy in some workplace such as interventional radiology and cardiology. The aim of this study is to evaluate different possible approaches in order to have a good estimate of the eye lens dose during interventional procedures. Measurements were performed with an X-ray system Philips Allura FD-10, using a PMMA phantom to simulate the patient scattered radiation and a Rando phantom to simulate the cardiologist. Thermoluminescence (TL) whole-body and TL eye lens dosemeters together with Philips DoseAware active dosemeters were located on different positions of the Rando phantom to estimate the eye lens dose in typical cardiology procedures. The results show that, for the studied conditions, any of the analysed dosemeter positions are suitable for eye lens dose assessment. However, the centre of the thyroid collar and the left ear position provide a better estimate. Furthermore, in practice, improper use of the ceiling-suspended screen can produce partial protection of some parts of the body, and thus large differences between the measured doses and the actual exposure of the eye could arise if the dosemeter is not situated close to the eye. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dose received by occupationally exposed workers at a nuclear medicine department
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avila, O.; Sanchez-Uribe, N. A.; Rodriguez-Laguna, A.
2012-10-23
Personal Dose Equivalent (PDE) values were determined for occupational exposed workers (OEW) at the Nuclear Medicine Department (NMD) of 'Instituto Nacional de Cancerologia' (INCan), Mexico, using TLD-100 thermoluminescent dosemeters. OEW at NMD, INCan make use of radiopharmaceuticals for diagnosis and treatment of diseases. Radionuclides associated to a pharmaceutical compound used at this Department are {sup 131}I, {sup 18}F, {sup 68}Ga, {sup 99m}Tc, {sup 111}In and {sup 11}C with main gamma emission energies between 140 and 511 keV. Dosemeter calibration was performed at the metrology department of 'Instituto Nacional de Investigaciones Nucleares' (ININ), Mexico. Every occupational worker used dark containers withmore » three dosimeters which were replaced monthly for a total of 5 periods. Additionally, control dosemeters were also placed at a site free of radioactive sources in order to determine the background radiation. Results were adjusted to find PDE/day and estimating annual PDE values in the range between 2 mSv (background) and 9 mSv. The mean annual value is 3.51 mSv and the standard deviation SD is 0.78 mSv. Four of the 16 OEW received annual doses higher than the average +1 SD (4.29 mSv). Results depend on OEW daily activities and were consistent for each OEW for the 5 studied periods as well as with PDE values reported by the firm that performs the monthly service. All obtained values are well within the established annual OEW dose limit stated in the {sup R}eglamento General de Seguridad Radiologica{sup ,} Mexico (50 mSv), as well as within the lower limit recommended by the 'International Commission on Radiation Protection' (ICRP), report no.60 (20 mSv). These results verify the adequate compliance of the NMD at INCan, Mexico with the norms given by the national regulatory commission.« less
Freitas, B M; Martins, M M; Pereira, W W; da Silva, A X; Mauricio, C L P
2016-09-01
The Brazilian Instituto de Radioproteção e Dosimetria (IRD) runs a neutron individual monitoring system with a home-made TLD albedo dosemeter. It has already been characterised and calibrated in some reference fields. However, the complete energy response of this dosemeter is not known, and the calibration factors for all monitored workplace neutron fields are difficult to be obtained experimentally. Therefore, to overcome such difficulties, Monte Carlo simulations have been used. This paper describes the simulation of the HP(10) neutron response of the IRD TLD albedo dosemeter using the MCNPX transport code, for energies from thermal to 20 MeV. The validation of the MCNPX modelling is done comparing the simulated results with the experimental measurements for ISO standard neutron fields of (241)Am-Be, (252)Cf, (241)Am-B and (252)Cf(D2O) and also for (241)Am-Be source moderated with paraffin and silicone. Bare (252)Cf are used for normalisation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Energy dependence of the response of lithium fluoride TLD rods in high energy electron fields.
Holt, J G; Edelstein, G R; Clark, T E
1975-07-01
The energy dependence of lithium fluoride dosemeters is a complicated function of energy as well as of cavity size. In the application of TLD to charged particle dosimetry, a cavity perturbation effect may exist even though the ratios of the mass stopping powers are constant over the energies encountered. This effect was investigated for lithium fluoride rods in electron fields ranging in energy from 2-5 to 20 MeV. A 13% change of TL response per unit of absorbed dose was measured over that energy range. A semi-empirical theory was developed to account for the cavity effect, using Burlin cavity theory as a starting point. The agreement between theory and measurement is satisfactory.
ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY.
Silva, E H; Knežević, Ž; Struelens, L; Covens, P; Ueno, S; Vanhavere, F; Buls, N
2016-09-01
Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radiophotoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0 up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK•CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruđer Bošković Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to Hp(3), although some improvements may be necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Microprocessor controlled portable TLD system
NASA Technical Reports Server (NTRS)
Apathy, I.; Deme, S.; Feher, I.
1996-01-01
An up-to-date microprocessor controlled thermoluminescence dosemeter (TLD) system for environmental and space dose measurements has been developed. The earlier version of the portable TLD system, Pille, was successfully used on Soviet orbital stations as well as on the US Space Shuttle, and for environmental monitoring. The new portable TLD system, Pille'95, consists of a reader and TL bulb dosemeters, and each dosemeter is provided with an EEPROM chip for automatic identification. The glow curve data are digitised and analysed by the program of the reader. The measured data and the identification number appear on the LED display of the reader. Up to several thousand measured data together with the glow curves can be stored on a removable flash memory card. The whole system is supplied either from built-in rechargeable batteries or from the mains of the space station.
FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS.
Clairand, I; Ginjaume, M; Vanhavere, F; Carinou, E; Daures, J; Denoziere, M; Silva, E H; Roig, M; Principi, S; Van Rycheghem, L
2016-09-01
In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Loncol, T; Greffe, J L; Vynckier, S; Scalliet, P
1996-11-01
In order to compare diodes and TLD for in vivo dosimetry, systematic measurements of entrance and exit doses were performed with semiconductor detectors and thermoluminescent dosemeters for brain and head and neck patients treated isocentrically with external photon beam therapy. Scanditronix EDP-20 diodes and 7LiF thermoluminescent chips, irradiated in a 8 MV linac, were studied with similar build-up cap geometries and materials in order to assure an equivalent electronic equilibrium. Identical calibration methodology was applied to both detectors for the dose determination in clinical conditions. For the entrance dose evaluation over 249 field measurements, the ratio of the measured dose to the expected dose, calculated from tabulated tissue maximum ratios, was equal to 1.010 +/- 0.028 (1 s.d.) from diodes and 1.013 +/- 0.041 from thermoluminescent crystals. For the exit dose measurements, these ratios were equal to 0.998 +/- 0.049 and 1.016 +/- 0.070 for diodes and TLDs, respectively, after application of a simple inhomogeneity correction to the calculation of the expected exit dose. Thermoluminescence and semiconductors led to identical results for entrance and exit dose evaluation but TLDs were characterised by a lower reproducibility inherent to the TL process itself and to the acquisition and annihilation procedures.
Dose rate constants for the quantity Hp(3) for frequently used radionuclides in nuclear medicine.
Szermerski, Bastian; Bruchmann, Iris; Behrens, Rolf; Geworski, Lilli
2016-12-01
According to recent studies, the human eye lens is more sensitive to ionising radiation than previously assumed. Therefore, the dose limit for personnel occupationally exposed to ionising radiation will be lowered from currently 150 mSv to 20 mSv per year. Currently, no data base for a reliable estimation of the dose to the lens of the eye is available for nuclear medicine. Furthermore, the dose is usually not monitored. The aim of this work was to determine dose rate constants for the quantity H p (3), which is supposed to estimate the dose to the lens of the eye. For this, H p (3)-dosemeters were fixed to an Alderson Phantom at different positions. The dosemeters were exposed to radiation from nuclides typically used in nuclear medicine in their geometries analog to their application in nuclear medicine, e.g. syringe or vial. The results show that the handling of high-energy beta (i.e. electron or positron) emitters may lead to a relevant dose to the lens of the eye. For low-energy beta emitters and gamma emitters, an exceeding of the lowered dose limit seems to be unlikely. Copyright © 2015. Published by Elsevier GmbH.
NASA Astrophysics Data System (ADS)
Behrens, R.
2015-03-01
The International Organization for Standardization (ISO) requires in its standard ISO 6980 that beta reference radiation fields for radiation protection be calibrated in terms of absorbed dose to tissue at a depth of 0.07 mm in a slab phantom (30 cm x 30 cm x 15 cm). However, many beta dosemeters are ring dosemeters and are, therefore, irradiated on a rod phantom (1.9 cm in diameter and 30 cm long), or they are eye dosemeters possibly irradiated on a cylinder phantom (20 cm in diameter and 20 cm high), or area dosemeters irradiated free in air with the conventional quantity value (true value) being defined in a sphere (30 cm in diameter, made of ICRU tissue (International Commission on Radiation Units and Measurements)). Therefore, the correction factors for the conventional quantity value in the rod, the cylinder, and the sphere instead of the slab (all made of ICRU tissue) were calculated for the radiation fields of 147Pm, 85Kr, 90Sr/90Y, and, 106Ru/106Rh sources of the beta secondary standard BSS 2 developed at PTB. All correction factors were calculated for 0° up to 75° (in steps of 15°) radiation incidence. The results are ready for implementation in ISO 6980-3 and have recently been (partly) implemented in the software of the BSS 2.
Assessment of eye lens doses for workers during interventional radiology procedures.
Urboniene, A; Sadzeviciene, E; Ziliukas, J
2015-07-01
The assessment of eye lens doses for workers during interventional radiology (IR) procedures was performed using a new eye lens dosemeter. In parallel, the results of routine individual monitoring were analysed and compared with the results obtained from measurements with a new eye lens dosemeter. The eye lens doses were assessed using Hp(3) measured at the level of the eyes and were compared with Hp(10) measured with the whole-body dosemeter above the lead collar. The information about use of protective measures, the number of performed interventional procedures per month and their fluoroscopy time was also collected. The assessment of doses to the lens of the eye was done for 50 IR workers at 9 Lithuanian hospitals for the period of 2012-2013. If the use of lead glasses is not taken into account, the estimated maximum annual dose equivalent to the lens of the eye was 82 mSv. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Deme, S; Apathy, I; Hejja, I; Lang, E; Feher, I
1999-01-01
A microprocessor-controlled on-board TLD system, 'Pille'96', was used during the NASA4 (1997) mission to monitor the cosmic radiation dose inside the Mir Space Station and to measure the extra dose to two astronauts in the course of their extravehicular activity (EVA). For the EVA dose measurements, CaSO4:Dy bulb dosemeters were located in specially designed pockets of the ORLAN spacesuits. During an EVA lasting 6 h, the dose ratio inside and outside Mir was measured. During the EVA, Mir crossed the South Atlantic Anomaly (SAA) three times. Taking into account the influence of these three crossings the mean EVA/internal dose rate ratio was 3.2. Internal dose mapping using CaSO4:Dy dosemeters gave mean dose rates ranging from 9.3 to 18.3 microGy h-1 at locations where the shielding effect was not the same. Evaluation results of the high temperature region of LiF dosemeters are given to estimate the mean LET.
USE OF A SIMPLE THERMALISED NEUTRON FIELD FOR QUALITY ACCEPTANCE OF WHOLE BODY TLDS.
Gilvin, P J; Baker, S T; Eakins, J S; Tanner, R J
2016-09-01
The individual monitoring service of Public Health England (PHE) uses Harshaw™ whole-body and extremity thermoluminescent dosemeters (TLDs) with high-sensitivity lithium fluoride LiF:Mg,Cu,P, together with Harshaw 8800™ automated readers. The neutron-insensitive, (6)Li-depleted variety of TLD material is used by PHE because the service provides separate neutron and photon dosemeters. The neutron dosemeters are not sensitive to photons and vice versa Since insensitivity to neutrons is a supply requirement for TLDs, there is a need to test every new (annual) consignment for this. Because it is thermal neutrons that produce a response in (6)Li TLDs, a thermal field is needed. To this end, PHE has adopted the simple approach of sandwiching the TLDs between two ISO water-filled slab phantoms. In this arrangement, the fast neutrons from an Am-Be source are effectively thermalised. Details of the method are given, together with the results of supporting MCNP calculations and some typical results. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Kato, Mamoru; Chida, Koichi; Moritake, Takashi; Koguchi, Yasuhiro; Sato, Tadaya; Oosaka, Hajime; Tosa, Tetsuo; Kadowaki, Ken
2014-12-01
Cardiac interventional procedures have been increasing year by year. However, radiation skin injuries have been still reported. There is a necessity to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not been established. To measure the ESD, a lot of radiophotoluminescence dosemeters (RPLDs) provide an accurate measurement of the direct actual ESD at the points they are arrayed. The purpose of this study was to examine the characteristics of RPLD to measure the ESD. As a result, X-ray permeable RPLD (with no tin filter) did not interfere with the percutaneous coronary intervention procedure. The RPLD also had good fundamental performance characteristics. Although the RPLD had a little energy dependence, it showed excellent dose and dose-rate linearity, and good angular dependence. In conclusion, by calibrating the energy dependence, RPLDs are useful dosemeter to measure the ESD in cardiac intervention. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chemical dosimetry system for criticality accidents.
Miljanić, Saveta; Ilijas, Boris
2004-01-01
Ruder Bosković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical dosemeter solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552 nm is responsible for a high sensitivity of the system: doses in the range 0.2-15 Gy can be measured. The dosemeter has been designed as a glass ampoule filled with the CET solution and inserted into a pen-shaped plastic holder. For dose determinations, a newly constructed optoelectronic reader has been used. The RBI team took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002, with the CET dosimetry system. For gamma ray dose determination TLD-700 TL detectors were used. The results obtained with CET dosemeter show very good agreement with the reference values.
A neutron dosemeter for nuclear criticality accidents.
d'Errico, F; Curzio, G; Ciolini, R; Del Gratta, A; Nath, R
2004-01-01
A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets.
Smith, M B; Akatov, Yu; Andrews, H R; Arkhangelsky, V; Chernykh, I V; Ing, H; Khoshooniy, N; Lewis, B J; Machrafi, R; Nikolaev, I; Romanenko, R Y; Shurshakov, V; Thirsk, R B; Tomi, L
2013-01-01
As part of the international Matroshka-R and Radi-N experiments, bubble detectors have been used on board the ISS in order to characterise the neutron dose and the energy spectrum of neutrons. Experiments using bubble dosemeters inside a tissue-equivalent phantom were performed during the ISS-16, ISS-18 and ISS-19 expeditions. During the ISS-20 and ISS-21 missions, the bubble dosemeters were supplemented by a bubble-detector spectrometer, a set of six detectors that was used to determine the neutron energy spectrum at various locations inside the ISS. The temperature-compensated spectrometer set used is the first to be developed specifically for space applications and its development is described in this paper. Results of the dose measurements indicate that the dose received at two different depths inside the phantom is not significantly different, suggesting that bubble detectors worn by a person provide an accurate reading of the dose received inside the body. The energy spectra measured using the spectrometer are in good agreement with previous measurements and do not show a strong dependence on the precise location inside the station. To aid the understanding of the bubble-detector response to charged particles in the space environment, calculations have been performed using a Monte-Carlo code, together with data collected on the ISS. These calculations indicate that charged particles contribute <2% to the bubble count on the ISS, and can therefore be considered as negligible for bubble-detector measurements in space.
FADING EFFECT OF LiF:Mg,Ti AND LiF:Mg,Cu,P Ext-Rad AND WHOLE-BODY DETECTORS.
Pereira, J; Pereira, M F; Rangel, S; Saraiva, M; Santos, L M; Cardoso, J V; Alves, J G
2016-09-01
Thermoluminescence dosemeters are widely used in individual and environmental monitoring. The aim of this work was to compare the thermal stability of dosemeters of the Ext-Rad and whole-body card types with LiF:Mg,Ti and LiF:Mg,Cu,P detectors stored at different temperatures and periods. The dosemeters were stored at 0°C, room temperature and 40°C for periods that lasted 8, 30, 45, 90 and 120 d. In general, TLD-100H detectors present higher TL signal stability than TLD-100 detectors. The intensity of the signal remained constant for both materials for storage periods at 0°C. At RT the same results was observed for TLD-100H. For TLD-100 detectors, a maximum variation of 22 % was registered for the longest period. At 40°C the TL signal decreased with storage time for both detectors. The TL signal of TLD-100H detectors presented maximum variations of 12 % whereas for TLD-100 detectors, larger variations of 25 % were observed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lee, K W; Sheu, R J
2015-04-01
High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with (252)Cf neutron sources and are used in various workplace. A workplace-specific correction factor is suggested. In this study, the effect of the neutron spectrum on the accuracy of dose measurements was investigated. A set of neutron spectra representing various neutron environments was selected to study the dose responses of a series of Bonner spheres, including standard and extended-range spheres. By comparing (252)Cf-calibrated dose responses with reference values based on fluence-to-dose conversion coefficients, this paper presents recommendations for neutron field characterisation and appropriate correction factors for responses of conventional neutron dosemeters used in environments with high-energy neutrons. The correction depends on the estimated percentage of high-energy neutrons in the spectrum or the ratio between the measured responses of two Bonner spheres (the 4P6_8 extended-range sphere versus the 6″ standard sphere). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ploc, Ondrej; Kubancak, Jan; Sihver, Lembit; Uchihori, Yukio; Jakubek, Jan; Ambrozova, Iva; Molokanov, Alexander; Pinsky, Lawrence
2014-01-01
Objective of our research was to explore capabilities of Timepix for its use as a single dosemeter and LET spectrometer in mixed radiation fields created by heavy ions. We exposed it to radiation field (i) at heavy ion beams at HIMAC, Chiba, Japan, (ii) in the CERN's high-energy reference field (CERF) facility at Geneva, France/Switzerland, (iii) in the exposure room of the proton therapy laboratory at JINR, Dubna, Russia, and (iv) onboard aircraft. We compared the absolute values of dosimetric quantities obtained with Timepix and with other dosemeters and spectrometers like tissue-equivalent proportional counter (TEPC) Hawk, silicon detector Liulin, and track-etched detectors (TEDs).
Walsh, C; Gallagher, A; Dowling, A; Guiney, M; Ryan, J M; McEniff, N; O'Reilly, G
2015-01-01
Objective: In 2011, the International Commission on Radiological Protection (ICRP) recommended a substantial reduction in the equivalent dose limit for the lens of the eye, in line with a reduced threshold of absorbed dose for radiation-induced cataracts. This is of particular relevance in interventional radiology (IR) where it is well established that staff doses can be significant, however, there is a lack of data on IR eye doses in terms of Hp(3). Hp(3) is the personal dose equivalent at a depth of 3 mm in soft tissue and is used for measuring lens dose. We aimed to obtain a reliable estimate of eye dose to IR operators. Methods: Lens doses were measured for four interventional radiologists over a 3-month period using dosemeters specifically designed to measure Hp(3). Results: Based on their typical workloads, two of the four interventional radiologists would exceed the new ICRP dose limit with annual estimated doses of 31 and 45 mSv to their left eye. These results are for an “unprotected” eye, and for IR staff who routinely wear lead glasses, the dose beneath the glasses is likely to be significantly lower. Staff eye dose normalized to patient kerma–area product and eye dose per procedure have been included in the analysis. Conclusion: Eye doses to IR operators have been established using a dedicated Hp(3) dosemeter. Estimated annual doses have the potential to exceed the new ICRP limit. Advances in knowledge: We have estimated lens dose to interventional radiologists in terms of Hp(3) for the first time in an Irish hospital setting. PMID:25761211
Shin, H-J; Song, J H; Jung, J-Y; Kwak, Y-K; Kay, C S; Kang, Y-N; Choi, B O; Jang, H S
2013-01-01
Objective: To evaluate the accuracy of pencil beam calculation (PBC) and Monte Carlo calculation (MCC) for dynamic arc therapy (DAT) in a cylindrically shaped homogenous phantom, by comparing the two plans with an ion chamber, a film and a three-dimensional (3D) volumetric dosemeter. Methods: For this study, an in-house phantom was constructed, and the PBC and MCC plans for DAT were performed using iPlan® RT (BrainLAB®, Heimstetten, Germany). The A16 micro ion chamber (Standard Imaging, Middleton, WI), Gafchromic® EBT2 film (International Specialty Products, Wayne, NJ) and ArcCHECK™ (Sun Nuclear, Melbourne, FL) were used for measurements. For comparison with each plan, two-dimensional (2D) and 3D gamma analyses were performed using 3%/3 mm and 2%/2 mm criteria. Results: The difference between the PBC and MCC plans using 2D and 3D gamma analyses was found to be 7.85% and 28.8%, respectively. The ion chamber and 2D dose distribution measurements did not exhibit this difference revealed by the comparison between the PBC and MCC plans. However, the 3D assessment showed a significant difference between the PBC and MCC (62.7% for PBC vs 93.4% for MCC, p = 0.034). Conclusion: Evaluation using a 3D volumetric dosemeter can be clinically useful for delivery quality assurance (QA), and the MCC should be used to achieve the most reliable dose calculation for DAT. Advances in knowledge: (1) The DAT plan calculated using the PBC has a limitation in the calculation methods, and a 3D volumetric dosemeter was found to be an adequate tool for delivery QA of DAT. (2) The MCC was superior to PBC in terms of the accuracy in dose calculation for DAT even in the homogenous condition. PMID:24234583
Limitations of silicon diodes for clinical electron dosimetry.
Song, Haijun; Ahmad, Munir; Deng, Jun; Chen, Zhe; Yue, Ning J; Nath, Ravinder
2006-01-01
This work investigates the relevance of several factors affecting the response of silicon diode dosemeters in depth-dose scans of electron beams. These factors are electron energy, instantaneous dose rate, dose per pulse, photon/electron dose ratio and electron scattering angle (directional response). Data from the literature and our own experiments indicate that the impact of these factors may be up to +/-15%. Thus, the different factors would have to cancel out perfectly at all depths in order to produce true depth-dose curves. There are reports of good agreement between depth-doses measured with diodes and ionisation chambers. However, our measurements with a Scantronix electron field detector (EFD) diode and with a plane-parallel ionisation chamber show discrepancies both in the build-up and in the low-dose regions, with a ratio up to 1.4. Moreover, the absolute sensitivity of two diodes of the same EFD model was found to differ by a factor of 3, and this ratio was not constant but changed with depth between 5 and 15% in the low-dose regions of some clinical electron beams. Owing to these inhomogeneities among diodes even of the same model, corrections for each factor would have to be diode-specific and beam-specific. All these corrections would have to be determined using parallel plane chambers, as recommended by AAPM TG-25, which would be unrealistic in clinical practice. Our conclusion is that in general diodes are not reliable in the measurement of depth-dose curves of clinical electron beams.
Scarboro, S. B.; Kry, S. F.
2013-01-01
Aluminium oxide (Al2O3:C) is a common material used in optically stimulated luminescent dosemeters (OSLDs). OSLDs have a known energy dependence, which can impact on the accuracy of dose measurements, especially for lower photon energies, where the dosemeter can overrespond by a factor of 3–4. The purpose of this work was to characterise the response of Al2O3:C using cavity theory and to evaluate the applicability of this approach for polyenergetic photon beams. The cavity theory energy response showed good agreement (within 2 %) with the corresponding measured values. A comparison with measured values reported in the literature for low-energy polyenergetic spectra showed more varied agreement (within 6 % on average). The discrepancy between these results is attributed to differences in the raw photon energy spectra used to calculate the energy response. Analysis of the impact of the photon energy spectra versus the mean photon energy showed improved accuracy if the energy response was determined using the entire photon spectrum rather than the mean photon energy. If not accounted for, the overresponse due to photon energy could introduce substantial inaccuracy in dose measurement using OSLDs, and the results of this study indicate that cavity theory may be used to determine the response with reasonable accuracy. PMID:22653437
Recalibration of indium foil for personnel screening in criticality accidents.
Takada, C; Tsujimura, N; Mikami, S
2011-03-01
At the Nuclear Fuel Cycle Engineering Laboratories of the Japan Atomic Energy Agency (JAEA), small pieces of indium foil incorporated into personal dosemeters have been used for personnel screening in criticality accidents. Irradiation tests of the badges were performed using the SILENE reactor to verify the calibration of the indium activation that had been made in the 1980s and to recalibrate them for simulated criticalities that would be the most likely to occur in the solution process line. In addition, Monte Carlo calculations of the indium activation using the badge model were also made to complement the spectral dependence. The results lead to a screening level of 15 kcpm being determined that corresponds to a total dose of 0.25 Gy, which is also applicable in posterior-anterior exposure. The recalibration based on the latest study will provide a sounder basis for the screening procedure in the event of a criticality accident.
X-ray studies of synthetic radiation-counting diamonds.
Yacoot, A; Moore, M; Makepeace, A
1990-10-01
Synthetic diamonds with a nitrogen content less than 100 ppm may be used as radiation dosemeters in a conduction counting mode, and are especially useful in medical applications. Crystal imperfections, revealed by x-ray diffraction topography, were found to affect counting performance. The best quality diamond gave the highest photocurrent (500 nA at 50 V mm-1 and 2.75 Gy min-1). Diamonds containing dislocations had lower photocurrents but had the advantage of shorter settling times (seconds rather than minutes). Placing contacts on two opposite cube (100) faces gave a higher photocurrent than on a pair of octahedral (111) faces. Higher photocurrents were also achieved when the majority of dislocations were perpendicular rather than parallel, to the electric field. Some recommendations for selecting synthetic diamonds for dosemeters are given.
Determination of quality parameters from statistical analysis of routine TLD dosimetry data.
German, U; Weinstein, M; Pelled, O
2006-01-01
Following the as low as reasonably achievable (ALARA) practice, there is a need to measure very low doses, of the same order of magnitude as the natural background, and the limits of detection of the dosimetry systems. The different contributions of the background signals to the total zero dose reading of thermoluminescence dosemeter (TLD) cards were analysed by using the common basic definitions of statistical indicators: the critical level (L(C)), the detection limit (L(D)) and the determination limit (L(Q)). These key statistical parameters for the system operated at NRC-Negev were quantified, based on the history of readings of the calibration cards in use. The electronic noise seems to play a minor role, but the reading of the Teflon coating (without the presence of a TLD crystal) gave a significant contribution.
Maki, Daisuke; Ishii, Tetsuya; Sato, Fuminobu; Kato, Yushi; Yamamoto, Takayoshi; Iida, Toshiyuki
2011-03-01
A confocal laser microscope system was developed for the measurement of radiophotoluminescence (RPL) photons emitted from a minute alpha-ray-irradiated area in an RPL glass dosemeter. The system was composed mainly of an inverted-type microscope, an ultraviolet laser, an XY movable stage and photon-counting circuits. The photon-counting circuits were effective in the reduction of the background noise level in the measurement of RPL photons. The performance of this microscope system was examined by the observation of standard RPL glass samples irradiated using (241)Am alpha rays. The spatial resolution of this system was ∼ 3 μm, and with regard to the sensitivity of this system, a hit of more than four to five alpha rays in unit area produced enough amount of RPL photons to construct the image.
Microdosemeter instrument (MIDN) for assessing risk in space.
Pisacane, V L; Dolecek, Q E; Malak, H; Cucinotta, F A; Zaider, M; Rosenfeld, A B; Rusek, A; Sivertz, M; Dicello, J F
2011-02-01
Radiation in space generally produces higher dose rates than that on the Earth's surface, and contributions from primary galactic and solar events increase with altitude within the magnetosphere. Presently, no personnel monitor is available to astronauts for real-time monitoring of dose, radiation quality and regulatory risk. This group is developing a prototypic instrument for use in an unknown, time-varying radiation field. This microdosemeter-dosemeter nucleon instrument is for use in a spacesuit, spacecraft, remote rover and other applications. It provides absorbed dose, dose rate and dose equivalent in real time so that action can be taken to reduce exposure. Such a system has applications in health physics, anti-terrorism and radiation-hardening of electronics as well. The space system is described and results of ground-based studies are presented and compared with predictions of transport codes. An early prototype in 2007 was successfully launched, the only solid-state microdosemeter to have flown in space.
Suzuki, Akira; Matsubara, Kosuke; Sasa, Yuko
2018-04-01
The present study aimed to determine doses delivered to the eye lenses of surgeons while using the inverted-C-arm technique and the protective effect of leaded spectacles during orthopedic surgery. The kerma in air was measured at five positions on leaded glasses positioned near the eye lens and on the neck using small optically stimulated luminescence (OSL) dosemeters. The lens equivalent dose was also measured at the neck using an OSL dosemeter. The maximum equivalent dose to the eye lens and the maximum kerma were 0.8 mSv/month and 0.66 mGy/month, respectively. The leaded glasses reduced the exposure by ~60%. Even if the surgeons are exposed to the maximum dose of X-ray radiation for 5 years, the equivalent doses to the eye lens will not exceed the present limit recommended by the ICRP.
NASA Astrophysics Data System (ADS)
Gómez-Ros, J. M.; Bedogni, R.; Moraleda, M.; Delgado, A.; Romero, A.; Esposito, A.
2010-01-01
This communication describes an improved design for a neutron spectrometer consisting of 6Li thermoluminescent dosemeters located at selected positions within a single moderating polyethylene sphere. The spatial arrangement of the dosemeters has been designed using the MCNPX Monte Carlo code to calculate the response matrix for 56 log-equidistant energies from 10 -9 to 100 MeV, looking for a configuration that permits to obtain a nearly isotropic response for neutrons in the energy range from thermal to 20 MeV. The feasibility of the proposed spectrometer and the isotropy of its response have been evaluated by simulating exposures to different reference and workplace neutron fields. The FRUIT code has been used for unfolding purposes. The results of the simulations as well as the experimental tests confirm the suitability of the prototype for environmental and workplace monitoring applications.
A method to characterise site, urban and regional ambient background radiation.
Passmore, C; Kirr, M
2011-03-01
Control dosemeters are routinely provided to customers to monitor the background radiation so that it can be subtracted from the gross response of the dosemeter to arrive at the occupational dose. Landauer, the largest dosimetry processor in the world with subsidiaries in Australia, Brazil, China, France, Japan, Mexico and the UK, has clients in approximately 130 countries. The Glenwood facility processes over 1.1 million controls per year. This network of clients around the world provides a unique ability to monitor the world's ambient background radiation. Control data can be mined to provide useful historical information regarding ambient background rates and provide a historical baseline for geographical areas. Historical baseline can be used to provide site or region-specific background subtraction values, document the variation in ambient background radiation around a client's site or provide a baseline for measuring the efficiency of clean-up efforts in urban areas after a dirty bomb detonation.
NASA Astrophysics Data System (ADS)
Ávila, O.; Torres-Ulloa, C. L.; Medina, L. A.; Trujillo-Zamudio, F. E.; de Buen, I. Gamboa; Buenfil, A. E.; Brandan, M. E.
2010-12-01
Ambient dose equivalent values were determined in several sites at the Instituto Nacional de Cancerología, Departmento de Medicina Nuclear, using TLD-100 and TLD-900 thermoluminescent dosemeters. Additionally, ambient dose equivalent was measured at a corridor outside the hospitalization room for patients treated with 137Cs brachytherapy. Dosemeter calibration was performed at the Instituto Nacional de Investigaciones Nucleares, Laboratorio de Metrología, to known 137Cs gamma radiation air kerma. Radionuclides considered for this study are 131I, 18F, 67Ga, 99mTc, 111In, 201Tl and 137Cs, with main gamma energies between 93 and 662 keV. Dosemeters were placed during a five month period in the nuclear medicine rooms (containing gamma-cameras), injection corridor, patient waiting areas, PET/CT study room, hot lab, waste storage room and corridors next to the hospitalization rooms for patients treated with 131I and 137Cs. High dose values were found at the waste storage room, outside corridor of 137Cs brachytherapy patients and PET/CT area. Ambient dose equivalent rate obtained for the 137Cs brachytherapy corridor is equal to (18.51±0.02)×10-3 mSv/h. Sites with minimum doses are the gamma camera rooms, having ambient dose equivalent rates equal to (0.05±0.03)×10-3 mSv/h. Recommendations have been given to the Department authorities so that further actions are taken to reduce doses at high dose sites in order to comply with the ALARA principle (as low as reasonably achievable).
In vivo dose verification method in catheter based high dose rate brachytherapy.
Jaselskė, Evelina; Adlienė, Diana; Rudžianskas, Viktoras; Urbonavičius, Benas Gabrielis; Inčiūra, Arturas
2017-12-01
In vivo dosimetry is a powerful tool for dose verification in radiotherapy. Its application in high dose rate (HDR) brachytherapy is usually limited to the estimation of gross errors, due to inability of the dosimetry system/ method to record non-uniform dose distribution in steep dose gradient fields close to the radioactive source. In vivo dose verification in interstitial catheter based HDR brachytherapy is crucial since the treatment is performed inserting radioactive source at the certain positions within the catheters that are pre-implanted into the tumour. We propose in vivo dose verification method for this type of brachytherapy treatment which is based on the comparison between experimentally measured and theoretical dose values calculated at well-defined locations corresponding dosemeter positions in the catheter. Dose measurements were performed using TLD 100-H rods (6 mm long, 1 mm diameter) inserted in a certain sequences into additionally pre-implanted dosimetry catheter. The adjustment of dosemeter positioning in the catheter was performed using reconstructed CT scans of patient with pre-implanted catheters. Doses to three Head&Neck and one Breast cancer patient have been measured during several randomly selected treatment fractions. It was found that the average experimental dose error varied from 4.02% to 12.93% during independent in vivo dosimetry control measurements for selected Head&Neck cancer patients and from 7.17% to 8.63% - for Breast cancer patient. Average experimental dose error was below the AAPM recommended margin of 20% and did not exceed the measurement uncertainty of 17.87% estimated for this type of dosemeters. Tendency of slightly increasing average dose error was observed in every following treatment fraction of the same patient. It was linked to the changes of theoretically estimated dosemeter positions due to the possible patient's organ movement between different treatment fractions, since catheter reconstruction was performed for the first treatment fraction only. These findings indicate potential for further average dose error reduction in catheter based brachytherapy by at least 2-3% in the case that catheter locations will be adjusted before each following treatment fraction, however it requires more detailed investigation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Assessment of medical occupational radiation doses in Costa Rica.
Mora, P; Acuña, M
2011-09-01
Participation of the University of Costa Rica (UCR) in activities in an IAEA Regional Project RLA/9/066 through training, equipment and expert missions, has enabled to setting up of a national personal monitoring laboratory. Since 2007, the UCR has been in charge of monitoring around 1800 medical radiation workers of the Social Security System. Individual external doses are measured with thermoluminescent dosemeter using a Harshaw 6600 Plus reader. The service has accreditation with ISO/IEC 17025:2005. Distribution of monitored medical personnel is as follows: 83 % in diagnostic radiology, 6 % in nuclear medicine and 6 % in radiotherapy. Preliminary values for the 75 percentile of annual H(p)(10) in mSv are: radiology 0.37; interventional radiology 0.41; radiotherapy 0.53 and nuclear medicine 1.55. The service provided by the UCR in a steady and reliable way can help to implement actions to limit the doses received by the medical workers and optimise their radiation protection programs.
Alarm inhalation dosemeter for long living radioactive dust due to an uncontrolled release
NASA Astrophysics Data System (ADS)
Streil, T.; Oeser, V.; Rambousky, R.; Buchholz, F. W.
2008-08-01
MyRIAM is the acronym for My Radioactivity In Air Monitor and points out that the device was designed for personal use to detect any radioactivity in the air at the place and at the moment of danger. The active air sampling process enables a detection limit several orders of magnitude below that of Gamma detectors. Therefore, it is the unique way to detect dangerous exposures in time. Individual protection against inhalation of long living radioactive dust (LLRD) saves human life and health. LLRD may occur in natural environment as well as in case of nuclear accidence or military and terrorist attacks. But in any case, the immediate warning of the population is of great importance. Keep in mind: it is very easy to avoid LLRD inhalation—but you have to recognize the imminent danger. The second requirement of gap-less documentation and reliable assessment of any derived LLRD exposure is building the link to Dosimetry applications. The paper demonstrates the possibility to design small and low cost air samplers, which can be used as personal alarm dosimeters and fulfil the requirements mentioned above. Several test measurements taken by a mobile phone sized MyRIAM, shall be used to demonstrate the correctness of this statement.
O'Connor, U; Gallagher, A; Malone, L; O'Reilly, G
2013-02-01
Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures. A new eye lens dosemeter (EYE-D(™), Radcard, Krakow, Poland) was used to measure the ERCP eye dose, H(p)(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out. The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma area product is also presented. Staff eye doses in ERCP have the potential to exceed the revised ICRP limit of 20 mSv per annum when an overcouch X-ray tube is used. The EYE-D dosemeter was found to be a convenient method for measuring lens dose. Eye doses in areas outside of radiology departments should be kept under review, particularly in light of the new ICRP eye dose limit. Occupational eye lens doses from ERCP procedures have been established using a new commercially available dedicated H(p)(3) dosemeter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avila, O.; Torres-Ulloa, C. L.; Facultad de Ciencias, Universidad Nacional Autonoma de Mexico, AP 70-542, 04510, DF
2010-12-07
Ambient dose equivalent values were determined in several sites at the Instituto Nacional de Cancerologia, Departmento de Medicina Nuclear, using TLD-100 and TLD-900 thermoluminescent dosemeters. Additionally, ambient dose equivalent was measured at a corridor outside the hospitalization room for patients treated with {sup 137}Cs brachytherapy. Dosemeter calibration was performed at the Instituto Nacional de Investigaciones Nucleares, Laboratorio de Metrologia, to known {sup 137}Cs gamma radiation air kerma. Radionuclides considered for this study are {sup 131}I, {sup 18}F, {sup 67}Ga, {sup 99m}Tc, {sup 111}In, {sup 201}Tl and {sup 137}Cs, with main gamma energies between 93 and 662 keV. Dosemeters were placedmore » during a five month period in the nuclear medicine rooms (containing gamma-cameras), injection corridor, patient waiting areas, PET/CT study room, hot lab, waste storage room and corridors next to the hospitalization rooms for patients treated with {sup 131}I and {sup 137}Cs. High dose values were found at the waste storage room, outside corridor of {sup 137}Cs brachytherapy patients and PET/CT area. Ambient dose equivalent rate obtained for the {sup 137}Cs brachytherapy corridor is equal to (18.51{+-}0.02)x10{sup -3} mSv/h. Sites with minimum doses are the gamma camera rooms, having ambient dose equivalent rates equal to (0.05{+-}0.03)x10{sup -3} mSv/h. Recommendations have been given to the Department authorities so that further actions are taken to reduce doses at high dose sites in order to comply with the ALARA principle (as low as reasonably achievable).« less
Response of pMOS dosemeters on gamma-ray irradiation during its re-use.
Pejovic, Milic M; Pejovic, Momcilo M; Jaksic, Aleksandar B
2013-08-01
Response of pMOS dosemeters during two successive irradiations with gamma-ray irradiation to a dose of 35 Gy and annealing at room and elevated temperature has been studied. The response was followed on the basis of threshold voltage shift, determined from transfer characteristics, as a function of absorbed dose or annealing time. It was shown that the threshold voltage shifts during first and second irradiation for the gate bias during irradiation of 5 and 2.5 V insignificantly differ although complete fading was not achieved after the first cycle of annealing. In order to analyse the defects formed in oxide and at the interface during irradiation and annealing, which are responsible for threshold voltage shift, midgap and charge-pumping techniques were used. It was shown that during first irradiation and annealing a dominant influence to threshold voltage shift is made by fixed oxide traps, while at the beginning of the second annealing cycle, threshold voltage shift is a consequence of both fixed oxide traps and slow switching traps.
Koivisto, Juha; Kiljunen, Timo; Wolff, Jan; Kortesniemi, Mika
2013-12-01
The objective of this study was to assess and compare the organ and effective doses in the knee area resulting from different commercially available multislice computed tomography devices (MSCT), one cone beam computed tomography device (CBCT) and one conventional X-ray radiography device using MOSFET dosemeters and an anthropomorphic RANDO knee phantom. Measurements of the MSCT devices resulted in effective doses ranging between 27 and 48 µSv. The CBCT measurements resulted in an effective dose of 12.6 µSv. The effective doses attained using the conventional radiography device were 1.8 µSv for lateral and 1.2 µSv for anterior-posterior projections. The effective dose resulting from conventional radiography was considerably lower than those recorded for the CBCT and MSCT devices. The MSCT effective dose results were two to four times higher than those measured on the CBCT device. This study demonstrates that CBCT can be regarded as a potential low-dose 3D imaging technique for knee examinations.
Mobit, P
2002-01-01
The energy responses of LiF-TLDs irradiated in megavoltage electron and photon beams have been determined experimentally by many investigators over the past 35 years but the results vary considerably. General cavity theory has been used to model some of the experimental findings but the predictions of these cavity theories differ from each other and from measurements by more than 13%. Recently, two groups or investigators using Monte Carlo simulations and careful experimental techniques showed that the energy response of 1 mm or 2 mm thick LiF-TLD irradiated by megavoltage photon and electron beams is not more than 5% less than unity for low-Z phantom materials like water or Perspex. However, when the depth of irradiation is significantly different from dmax and the TLD size is more than 5 mm, then the energy response is up to 12% less than unity for incident electron beams. Monte Carlo simulations of some of the experiments reported in the literature showed that some of the contradictory experimental results are reproducible with Monte Carlo simulations. Monte Carlo simulations show that the energy response of LiF-TLDs depends on the size of detector used in electron beams, the depth of irradiation and the incident electron energy. Other differences can be attributed to absolute dose determination and precision of the TL technique. Monte Carlo simulations have also been used to evaluate some of the published general cavity theories. The results show that some of the parameters used to evaluate Burlin's general cavity theory are wrong by factor of 3. Despite this, the estimation of the energy response for most clinical situations using Burlin's cavity equation agrees with Monte Carlo simulations within 1%.
Ali, F; Waker, A J; Waller, E J
2014-10-01
Tissue-equivalent proportional counters (TEPC) can potentially be used as a portable and personal dosemeter in mixed neutron and gamma-ray fields, but what hinders this use is their typically large physical size. To formulate compact TEPC designs, the use of a Monte Carlo transport code is necessary to predict the performance of compact designs in these fields. To perform this modelling, three candidate codes were assessed: MCNPX 2.7.E, FLUKA 2011.2 and PHITS 2.24. In each code, benchmark simulations were performed involving the irradiation of a 5-in. TEPC with monoenergetic neutron fields and a 4-in. wall-less TEPC with monoenergetic gamma-ray fields. The frequency and dose mean lineal energies and dose distributions calculated from each code were compared with experimentally determined data. For the neutron benchmark simulations, PHITS produces data closest to the experimental values and for the gamma-ray benchmark simulations, FLUKA yields data closest to the experimentally determined quantities. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Martin, Colin J
2016-06-01
Doses to the eye lenses of clinicians undertaking fluoroscopically guided procedures can exceed the dose annual limit of 20 mSv, so optimisation of radiation protection is essential. Ceiling-suspended shields and disposable radiation absorbing pads can reduce eye dose by factors of 2-7. Lead glasses that shield against exposures from the side can lower doses by 2.5-4.5 times. Training in effective use of protective devices is an essential element in achieving good protection and acceptable eye doses. Effective methods for dose monitoring are required to identify protection issues. Dosemeters worn adjacent to the eye provide the better option for interventional clinicians, but an unprotected dosemeter worn at the neck will give an indication of eye dose that is adequate for most interventional staff. Potential requirements for protective devices and dose monitoring can be determined from risk assessments using generic values for dose linked to examination workload. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy
O'Keeffe, S; McCarthy, D; Woulfe, P; Grattan, M W D; Hounsell, A R; Sporea, D; Mihai, L; Vata, I; Leen, G
2015-01-01
This article presents an overview of the recent developments and requirements in radiotherapy dosimetry, with particular emphasis on the development of optical fibre dosemeters for radiotherapy applications, focusing particularly on in vivo applications. Optical fibres offer considerable advantages over conventional techniques for radiotherapy dosimetry, owing to their small size, immunity to electromagnetic interferences, and suitability for remote monitoring and multiplexing. The small dimensions of optical fibre-based dosemeters, together with being lightweight and flexible, mean that they are minimally invasive and thus particularly suited to in vivo dosimetry. This means that the sensor can be placed directly inside a patient, for example, for brachytherapy treatments, the optical fibres could be placed in the tumour itself or into nearby critical tissues requiring monitoring, via the same applicators or needles used for the treatment delivery thereby providing real-time dosimetric information. The article outlines the principal sensor design systems along with some of the main strengths and weaknesses associated with the development of these techniques. The successful demonstration of these sensors in a range of different clinical environments is also presented. PMID:25761212
Electronic Personal Health Record Use Among Nurses in the Nursing Informatics Community.
Gartrell, Kyungsook; Trinkoff, Alison M; Storr, Carla L; Wilson, Marisa L
2015-07-01
An electronic personal health record is a patient-centric tool that enables patients to securely access, manage, and share their health information with healthcare providers. It is presumed the nursing informatics community would be early adopters of electronic personal health record, yet no studies have been identified that examine the personal adoption of electronic personal health record's for their own healthcare. For this study, we sampled nurse members of the American Medical Informatics Association and the Healthcare Information and Management Systems Society with 183 responding. Multiple logistic regression analysis was used to identify those factors associated with electronic personal health record use. Overall, 72% were electronic personal health record users. Users tended to be older (aged >50 years), be more highly educated (72% master's or doctoral degrees), and hold positions as clinical informatics specialists or chief nursing informatics officers. Those whose healthcare providers used electronic health records were significantly more likely to use electronic personal health records (odds ratio, 5.99; 95% confidence interval, 1.40-25.61). Electronic personal health record users were significantly less concerned about privacy of health information online than nonusers (odds ratio, 0.32; 95% confidence interval, 0.14-0.70) adjusted for ethnicity, race, and practice region. Informatics nurses, with their patient-centered view of technology, are in prime position to influence development of electronic personal health records. Our findings can inform policy efforts to encourage informatics and other professional nursing groups to become leaders and users of electronic personal health record; such use could help them endorse and engage patients to use electronic personal health records. Having champions with expertise in and enthusiasm for the new technology can promote the adoptionof electronic personal health records among healthcare providers as well as their patients.
49 CFR 220.305 - Use of personal electronic devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD COMMUNICATIONS Electronic Devices § 220.305 Use of personal electronic devices. A railroad operating employee must have each personal electronic device turned off with... 49 Transportation 4 2010-10-01 2010-10-01 false Use of personal electronic devices. 220.305...
49 CFR 220.305 - Use of personal electronic devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Use of personal electronic devices. 220.305... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD COMMUNICATIONS Electronic Devices § 220.305 Use of personal electronic devices. A railroad operating employee must have each personal electronic device turned off with...
49 CFR 220.305 - Use of personal electronic devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Use of personal electronic devices. 220.305... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD COMMUNICATIONS Electronic Devices § 220.305 Use of personal electronic devices. A railroad operating employee must have each personal electronic device turned off with...
Ordiales, J M; Nogales, J M; Vano, E; López-Mínguez, J R; Alvarez, F J; Ramos, J; Martínez, G; Sánchez, R M
2017-04-25
The aim of this study was to evaluate the occupational radiation dose in interventional cardiology by using a shielding drape on the patient. A random study with and without the protective material was conducted. The following control parameters were registered: demographic data, number of stents, contrast media volume, fluoroscopy time, number of cine images, kerma-area product and cumulative air kerma. Occupational dose data were obtained by electronic active dosemeters. No statistically significant differences in the analysed control parameters were registered. The median dose value received by the interventional cardiologist was 50% lower in the group with a shielding drape with a statistically significant p-value <0.001. In addition, the median value of the maximum scatter radiation dose was 31% lower in this group with a statistically significant p-value <0.001. This study showed that a shielding drape is a useful tool for reducing the occupational radiation dose in a cardiac catheterisation laboratory. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Sannappa, J; Ningappa, C
2014-03-01
An extensive studies on the indoor activity concentrations of thoron, radon and their progeny in the granite region in the state of Karnataka, India, has been carried out since, 2007 in the scope of a lung cancer epidemiological study using solid-state nuclear track detector-based double-chamber dosemeters (LR-115, type II plastic track detector). Seventy-four dwellings of different types were selected for the measurement. The dosemeters containing SSNTD detectors were fixed 2 m above the floor. After an exposure time of 3 months (90 d), films were etched to reveal tracks. From the track density, the concentrations of radon and thoron were evaluated. The value of the indoor concentration of thoron and radon in the study area varies from 16 to 170 Bq m(-3) and 18 to 300 Bq m(-3) with medians of 66 and 82.3 Bq m(-3), respectively, and that of their progeny varies from 1.8 to 24 mWL with a median of 3.6 mWL and 1.6 to 19.6 mWL, respectively. The concentrations of indoor thoron, radon and their progeny and their equivalent effective doses are discussed.
Akhilesh, Philomina; Kulkarni, Arti R; Jamhale, Shramika H; Sharma, S D; Kumar, Rajesh; Datta, D
2017-04-25
The purpose of this study was to estimate eye lens dose during brain scans in 16-, 64-, 128- and 256-slice multidetector computed tomography (CT) scanners in helical acquisition mode and to test the feasibility of using radiochromic film as eye lens dosemeter during CT scanning. Eye lens dose measurements were performed using Gafchromic XR-QA2 film on a polystyrene head phantom designed with outer dimensions equivalent to the head size of a reference Indian man. The response accuracy of XR-QA2 film was validated by using thermoluminescence dosemeters. The eye lens dose measured using XR-QA2 film on head phantom for plain brain scanning in helical mode ranged from 43.8 to 45.8 mGy. The XR-QA2 film measured dose values were in agreement with TLD measured dose values within a maximum variation of 8.9%. The good correlation between the two data sets confirms the viability of using XR-QA2 film for eye lens dosimetry. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
On the use of LiF:Mg,Ti thermoluminescence dosemeters in space--a critical review.
Horowitz, Y S; Satinger, D; Fuks, E; Oster, L; Podpalov, L
2003-01-01
The use of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) in space radiation fields is reviewed. It is demonstrated in the context of modified track structure theory and microdosimetric track structure theory that there is no unique correlation between the relative thermoluminescence (TL) efficiency of heavy charged particles, neutrons of all energies and linear energy transfer (LET). Many experimental measurements dating back more than two decades also demonstrate the multivalued, non-universal, relationship between relative TL efficiency and LET. It is further demonstrated that the relative intensities of the dosimetric peaks and especially the high-temperature structure are dependent on a large number of variables, some controllable, some not. It is concluded that TL techniques employing the concept of LET (e.g. measurement of total dose, the high-temperature ratio (HTR) methods and other combinations of the relative TL efficiency of the various peaks used to estimate average Q or simulate Q-LET relationships) should be regarded as lacking a sound theoretical basis, highly prone to error and, as well, lack of reproducibility/universality due to the absence of a standardised experimental protocol essential to reliable experimental methodology.
Silva, A I V; Brasil, D M; Vasconcelos, K F; Haiter Neto, F; Boscolo, F N
2015-01-01
Objectives: To assess the efficacy of lead foils in reducing the radiation dose received by different anatomical sites of the head and neck during periapical intraoral examinations performed with digital systems. Methods: Images were acquired through four different manners: phosphor plate (PSP; VistaScan® system; Dürr Dental GmbH, Bissingen, Germany) alone, PSP plus lead foil, complementary metal oxide semiconductor (CMOS; DIGORA® Toto, Soredex®, Tuusula, Finland) alone and CMOS plus lead foil. Radiation dose was measured after a full-mouth periapical series (14 radiographs) using the long-cone paralleling technique. Lithium fluoride (LiF 100) thermoluminescent dosemeters were placed in an anthropomorphic phantom at points corresponding to the tongue, thyroid, crystalline lenses, parotid glands and maxillary sinuses. Results: Dosemeter readings demonstrated the efficacy of the addition of lead foil in the intraoral digital X-ray systems provided in reducing organ doses in the selected structures, approximately 32% in the PSP system and 59% in the CMOS system. Conclusions: The use of lead foils associated with digital X-ray sensors is an effective alternative for the protection of different anatomical sites of the head and neck during full-mouth periapical series acquisition. PMID:26084474
Automation of film densitometry for application in personal monitoring.
Taheri, M; Movafeghi, A; Rastkhah, N
2011-03-01
In this research work, a semi-automatic densitometry system has been developed for large-scale monitoring services by use of film badge dosemeters. The system consists of a charge-coupled device (CCD)-based scanner that can scan optical densities (ODs) up to 4.2, a computer vision algorithm to improve the quality of digitised films and an analyser program to calculate the necessary information, e.g. the mean OD of region of interest and radiation doses. For calibration of the system, two reference films were used. The Microtek scanner International Color Consortium (ICC) profiler is applied for determining the colour attributes of the scanner accurately and a reference of the density step tablet, Bundesanstalt für Materialforschung und-prüfung (BAM) is used for calibrating the automatic conversion of gray-level values to OD values in the range of 0.2-4.0 OD. The system contributes to achieve more objectives and reliable results. So by applying this system, we can digitise a set of 20 films at once and calculate their relative doses less than about 4 min, and meanwhile it causes to avoid disadvantages of manual process and to enhance the accuracy of dosimetry.
Personal, Electronic, Secure National Library of Medicine Hosts Health Records Conference
... Bar Home Current Issue Past Issues EHR Personal, Electronic, Secure: National Library of Medicine Hosts Health Records ... One suggestion for saving money is to implement electronic personal health records. With this in mind, the ...
Depth dose and off-axis characteristics of TLD in therapeutic pion beams.
Hogstrom, K R; Irifune, T
1980-07-01
The thermoluminescent (TL) response of LiF (TLD-100, TLD-600, TLD-700) and Li2B4O7 (TLD-800) has been measured as a function of depth and off-axis position in a therapeutic negative-pion beam in order to evaluate their usefulness in pion radiotherapy. TLD-100, TLD-600, and TLD-800 have been shown to be of little use as in vivo dosemeters because the neutron kerma relative to that in tissue changes grossly with depth. The neutron source comes primarily from pion absorption in the lead-alloy collimator. The 200 degrees C TLD-700 response agrees well with the depth dose spectra, except for small changes due to the varying linear energy transfer (LET) distributions. This variation can be partially accounted for by incorporating the known LET response of LiF. The 260 degrees C peak of TLD-700 has been found to be approximately four times more sensitive than the 200 degrees C peak to high LET dose. Using a simple model of the LET responses, the measured 200 degrees C and 260 degrees C peaks predict total dose within +/- 4% and high LET dose within +/- 50%, therefore indicating TLD-700 to be a good in vivo dosemeter for total dose but only an indicator of high LET dose.
AIR TOXICS EMISSIONS FROM ELECTRONICS INCINERATION
The purpose of this project is to examine the emissions of air toxics from the combustion of electronics equipment, primarily personal computer components. Due to a shortage of recycling programs for personal computers and other personal electronics equipment, most of these mate...
Critical Infrastructure References: Documented Literature Search
2012-10-01
the literature search document can be a resource for DRDC and external partners. Future plans: At present, the electronic copies of the reference...Personal Information Protection and Electronic Documents Act (S.C. 2000, c. 5) Title: Personal Information Protection and Electronic Documents Act (S.C...2011 Overview: • "An Act to support and promote electronic commerce by protecting personal information that is collected, used or disclosed in
17 CFR 232.100 - Persons and entities subject to mandated electronic filing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... to mandated electronic filing. 232.100 Section 232.100 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION REGULATION S-T-GENERAL RULES AND REGULATIONS FOR ELECTRONIC FILINGS Electronic Filing Requirements § 232.100 Persons and entities subject to mandated electronic filing. The following...
17 CFR 232.100 - Persons and entities subject to mandated electronic filing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... to mandated electronic filing. 232.100 Section 232.100 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION REGULATION S-T-GENERAL RULES AND REGULATIONS FOR ELECTRONIC FILINGS Electronic Filing Requirements § 232.100 Persons and entities subject to mandated electronic filing. The following...
17 CFR 232.100 - Persons and entities subject to mandated electronic filing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... to mandated electronic filing. 232.100 Section 232.100 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION REGULATION S-T-GENERAL RULES AND REGULATIONS FOR ELECTRONIC FILINGS Electronic Filing Requirements § 232.100 Persons and entities subject to mandated electronic filing. The following...
17 CFR 232.100 - Persons and entities subject to mandated electronic filing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... to mandated electronic filing. 232.100 Section 232.100 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION REGULATION S-T-GENERAL RULES AND REGULATIONS FOR ELECTRONIC FILINGS Electronic Filing Requirements § 232.100 Persons and entities subject to mandated electronic filing. The following...
17 CFR 232.100 - Persons and entities subject to mandated electronic filing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... to mandated electronic filing. 232.100 Section 232.100 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION REGULATION S-T-GENERAL RULES AND REGULATIONS FOR ELECTRONIC FILINGS Electronic Filing Requirements § 232.100 Persons and entities subject to mandated electronic filing. The following...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-13
... Armenia, two persons in China, seven persons in Hong Kong, four persons in Malaysia and two persons in.... Hakobyan 3, Yerevan, Armenia. China (1) Chitron Electronics Company Ltd, a.k.a., Chi-Chuang Electronics Company Ltd (Chitron-Shenzhen), 2127 Sungang Rd, Huatong Bldg, 19/F, Louhu Dist, Shenzhen, China 518001...
Kowatari, Munehiko; Tanimura, Yoshihiko; Tsutsumi, Masahiro
2014-12-01
The 6- to 7-MeV high-energy gamma-ray calibration field by the (19)F(p, αγ)(16)O reaction is to be served at the Japan Atomic Energy Agency. For the determination of air kerma rates using an ionisation chamber in the 6- to 7-MeV high-energy gamma-ray field, the establishment of the charged particle equilibrium must be achieved during measurement. In addition to measurement of air kerma rates by the ionisation chamber with a thick build-up cap, measurement using the ionisation chamber and a build-up plate (BUP) was attempted, in order to directly determine air kerma rates under the condition of regular calibration for ordinary survey meters and personal dosemeters. Before measurements, Monte Carlo calculations were made to find the optimum arrangement of BUP in front of the ionisation chamber so that the charged particle equilibrium could be well established. Measured results imply that air kerma rates for the 6- to 7-MeV high-energy gamma-ray field could be directly determined under the appropriate condition using an ionisation chamber coupled with build-up materials. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Othman, M A R; Cutajar, D L; Hardcastle, N; Guatelli, S; Rosenfeld, A B
2010-09-01
Monte Carlo simulations of the energy response of a conventionally packaged single metal-oxide field effect transistors (MOSFET) detector were performed with the goal of improving MOSFET energy dependence for personal accident or military dosimetry. The MOSFET detector packaging was optimised. Two different 'drop-in' design packages for a single MOSFET detector were modelled and optimised using the GEANT4 Monte Carlo toolkit. Absorbed photon dose simulations of the MOSFET dosemeter placed in free-air response, corresponding to the absorbed doses at depths of 0.07 mm (D(w)(0.07)) and 10 mm (D(w)(10)) in a water equivalent phantom of size 30 x 30 x 30 cm(3) for photon energies of 0.015-2 MeV were performed. Energy dependence was reduced to within + or - 60 % for photon energies 0.06-2 MeV for both D(w)(0.07) and D(w)(10). Variations in the response for photon energies of 15-60 keV were 200 and 330 % for D(w)(0.07) and D(w)(10), respectively. The obtained energy dependence was reduced compared with that for conventionally packaged MOSFET detectors, which usually exhibit a 500-700 % over-response when used in free-air geometry.
Pohorecki, Wladyslaw; Obryk, Barbara
2017-09-29
The results of nuclear heating measured by means of thermoluminescent dosemeters (TLD-LiF) in a Cu block irradiated by 14 MeV neutrons are presented. The integral Cu experiment relevant for verification of copper nuclear data at neutron energies characteristic for fusion facilities was performed in the ENEA FNG Laboratory at Frascati. Five types of TLDs were used: highly photon sensitive LiF:Mg,Cu,P (MCP-N), 7LiF:Mg,Cu,P (MCP-7) and standard, lower sensitivity LiF:Mg,Ti (MTS-N), 7LiF:Mg,Ti (MTS-7) and 6LiF:Mg,Ti (MTS-6). Calibration of the detectors was performed with gamma rays in terms of air-kerma (10 mGy of 137Cs air-kerma). Nuclear heating in the Cu block was also calculated with the use of MCNP transport code Nuclear heating in Cu and air in TLD's positions was calculated as well. The nuclear heating contribution from all simulated by MCNP6 code particles including protons, deuterons, alphas tritons and heavier ions produced by the neutron interactions were calculated. A trial of the direct comparison between experimental results and results of simulation was performed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
49 CFR 213.369 - Inspection records.
Code of Federal Regulations, 2010 CFR
2010-10-01
... transfer records through electronic transmission, storage, and retrieval provided that— (1) The electronic... security such as recognition of an electronic signature, or other means, which uniquely identify the initiating person as the author of that record. No two persons shall have the same electronic identity; (2...
Puchalska, Monika; Bilski, Pawel; Berger, Thomas; Hajek, Michael; Horwacik, Tomasz; Körner, Christine; Olko, Pawel; Shurshakov, Vyacheslav; Reitz, Günther
2014-11-01
The health effects of cosmic radiation on astronauts need to be precisely quantified and controlled. This task is important not only in perspective of the increasing human presence at the International Space Station (ISS), but also for the preparation of safe human missions beyond low earth orbit. From a radiation protection point of view, the baseline quantity for radiation risk assessment in space is the effective dose equivalent. The present work reports the first successful attempt of the experimental determination of the effective dose equivalent in space, both for extra-vehicular activity (EVA) and intra-vehicular activity (IVA). This was achieved using the anthropomorphic torso phantom RANDO(®) equipped with more than 6,000 passive thermoluminescent detectors and plastic nuclear track detectors, which have been exposed to cosmic radiation inside the European Space Agency MATROSHKA facility both outside and inside the ISS. In order to calculate the effective dose equivalent, a numerical model of the RANDO(®) phantom, based on computer tomography scans of the actual phantom, was developed. It was found that the effective dose equivalent rate during an EVA approaches 700 μSv/d, while during an IVA about 20 % lower values were observed. It is shown that the individual dose based on a personal dosimeter reading for an astronaut during IVA results in an overestimate of the effective dose equivalent of about 15 %, whereas under an EVA conditions the overestimate is more than 200 %. A personal dosemeter can therefore deliver quite good exposure records during IVA, but may overestimate the effective dose equivalent received during an EVA considerably.
ERIC Educational Resources Information Center
Havik, Else M.; Steyvers, Frank J. J. M.; van der Velde, Hanneke; Pinkster, J. Christiaan; Kooijman, Aart C.
2010-01-01
This study evaluated a protocol that was developed to assess how beneficial electronic travel aids are for persons who are visually impaired. Twenty persons with visual impairments used an electronic travel device (Trekker) for six weeks to conform to the protocol, which proved useful in identifying successful users of the device. (Contains 2…
17 CFR 260.0-2 - Definitions of terms used in the rules and regulations.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Electronic filing. The term electronic filing means a document under the federal securities laws that is... “control” means the power to direct the management and policies of a person, directly or through one or...) Electronic filer. The term electronic filer means a person or an entity that submits filings electronically...
17 CFR 260.0-2 - Definitions of terms used in the rules and regulations.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Electronic filing. The term electronic filing means a document under the federal securities laws that is... “control” means the power to direct the management and policies of a person, directly or through one or...) Electronic filer. The term electronic filer means a person or an entity that submits filings electronically...
17 CFR 260.0-2 - Definitions of terms used in the rules and regulations.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Electronic filing. The term electronic filing means a document under the federal securities laws that is... “control” means the power to direct the management and policies of a person, directly or through one or...) Electronic filer. The term electronic filer means a person or an entity that submits filings electronically...
17 CFR 260.0-2 - Definitions of terms used in the rules and regulations.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) Electronic filing. The term electronic filing means a document under the federal securities laws that is... “control” means the power to direct the management and policies of a person, directly or through one or...) Electronic filer. The term electronic filer means a person or an entity that submits filings electronically...
17 CFR 260.0-2 - Definitions of terms used in the rules and regulations.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Electronic filing. The term electronic filing means a document under the federal securities laws that is... “control” means the power to direct the management and policies of a person, directly or through one or...) Electronic filer. The term electronic filer means a person or an entity that submits filings electronically...
Modern Electronic Devices: An Increasingly Common Cause of Skin Disorders in Consumers.
Corazza, Monica; Minghetti, Sara; Bertoldi, Alberto Maria; Martina, Emanuela; Virgili, Annarosa; Borghi, Alessandro
2016-01-01
: The modern conveniences and enjoyment brought about by electronic devices bring with them some health concerns. In particular, personal electronic devices are responsible for rising cases of several skin disorders, including pressure, friction, contact dermatitis, and other physical dermatitis. The universal use of such devices, either for work or recreational purposes, will probably increase the occurrence of polymorphous skin manifestations over time. It is important for clinicians to consider electronics as potential sources of dermatological ailments, for proper patient management. We performed a literature review on skin disorders associated with the personal use of modern technology, including personal computers and laptops, personal computer accessories, mobile phones, tablets, video games, and consoles.
Steiner, Riley J; Rasberry, Catherine N
2015-08-01
Although associations between bullying and health risk behaviors are well-documented, research on bullying and education-related outcomes, including school attendance, is limited. This study examines associations between bullying victimization (in-person and electronic) and missing school because of safety concerns among a nationally representative sample of U.S. high school students. We used logistic regression analyses to analyze data from the 2013 national Youth Risk Behavior Survey of students in grades 9-12. In-person and electronic victimization were each associated with increased odds of missing school due to safety concerns compared to no bullying victimization. Having been bullied both in-person and electronically was associated with greater odds of missing school compared to electronic bullying only for female students and in-person bullying only for male students. Collaborations between health professionals and educators to prevent bullying may improve school attendance. Published by Elsevier Ltd.
Emergency EPR and OSL dosimetry with table vitamins and minerals.
Sholom, S; McKeever, S W S
2016-12-01
Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated prominent OSL signals after exposure to ionizing radiation doses. Basic dosimetric properties of the radiation-sensitive substances were studied, namely dose response, fading of the EPR or OSL signals and values of minimum measurable doses (MMDs). For EPR-sensitive samples, the EPR signal is converted into units of dose using a linear dose response and correcting for fading using the measured fading dependence. For OSL-sensitive materials, a multi-aliquot, enhanced-temperature protocol was developed to avoid the problem of sample sensitization and to minimize the influence of signal fading. The sample dose in this case is also evaluated using the dose response and fading curves. MMDs of the EPR-sensitive samples were below 2 Gy while those of the OSL-sensitive materials were below 500 mGy as long as the samples are analyzed within 1 week after exposure. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
ASSESSMENT OF INHALATION DOSE FROM THE INDOOR 222Rn AND 220Rn USING RAD7 AND PINHOLE CUP DOSEMETERS.
Mehra, R; Jakhu, R; Bangotra, P; Kaur, K; Mittal, H M
2016-10-01
Radon is the most important source of natural radiation and is responsible for approximately half of the received dose from all sources. Most of this dose is from inhalation of the radon progeny, especially in closed atmospheres. Concentration of radon ( 222 Rn) and thoron ( 220 Rn) in the different villages of Jalandhar and Kapurthala district of Punjab has been calculated by pinhole cup dosemeters and RAD7. On an average, it has been observed from the study that the values of all the parameters calculated are higher in case of active monitoring than the passive monitoring. The calculated equilibrium equivalent 222 Rn concentration (EEC Rn ) and equilibrium equivalent 220 Rn concentration (EEC Th ) fluctuate in the range from 5.58 to 34.29 and from 0.35 to 2.7 Bq m -3 as estimated by active technique, respectively. Similarly, the observed mean value of the potential alpha energy concentration of 222 Rn (PAEC Rn ) and 220 Rn (PAEC Th ) is 4.55 and 4.34 mWL, respectively. The dose rate to the soft tissues and lung from indoor 222 Rn varies from 0.06 to 0.38 and from 0.50 to 3.05 nGy h -1 , respectively. The total annual effective dose for the residents of the study area is less than 10 mSv. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Electronic Travel Aids for Blind Persons.
ERIC Educational Resources Information Center
Hill, Everett W.; Bradfield, Anna L.
1987-01-01
The article describes four of the most widely accepted and utilized Electronic Travel Aids for blind persons--the Lindsay Russell Pathsounder, the Mowat Sensor, the Sonicguide, and the C-5 Laser Cane. Current uses and applications of the four aids for specific populations of visually impaired persons are discussed. (Author)
5 CFR 850.303 - Return of personal documents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... REGULATIONS (CONTINUED) ELECTRONIC RETIREMENT PROCESSING Records § 850.303 Return of personal documents. An..., OPM may provide the individual with a copy of the document that is derived from electronic records. ... 5 Administrative Personnel 2 2014-01-01 2014-01-01 false Return of personal documents. 850.303...
Eye Lens Radiation Exposure in Greek Interventional Cardiology Article.
Thrapsanioti, Zoi; Askounis, Panagiotis; Datseris, Ioannis; Diamanti, Ramza Anastasia; Papathanasiou, Miltiadis; Carinou, Eleftheria
2017-07-01
The lens of the eye is one of the radiosensitive tissues of the human body; if exposed to ionizing radiation can develop radiation-induced cataract at early ages. This study was held in Greece and included 44 Interventional Cardiologists (ICs) and an unexposed to radiation control group of 22 persons. Of the note, 26 ICs and the unexposed individuals underwent special eye examinations. The detected lens opacities were classified according to LOCS III protocol. Additionally, the lens doses of the ICs were measured using eye lens dosemeters. The mean dose to the lenses of the ICs per month was 0.83 ± 0.59 mSv for the left and 0.35 ± 0.38 mSv for the right eye, while the annual doses ranged between 0.7 and 11 mSv. Regarding the lens opacities, the two groups did not differ significantly in the prevalence of either nuclear or cortical lens opacities, whereas four ICs were detected with early stage subcapsular sclerosis. Though no statistically difference was observed in the cohort, the measured doses indicate that the eye doses received from the ICs can be significant. To minimize the radiation-induced risk at the eye lenses, the use of protective equipment and appropriate training on this issue is highly recommended. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-29
... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Order No. 1671] Approval for Processing Authority, Foreign-Trade Zone 196, ATC Logistics & Electronics (Personal Navigation Devices), Fort Worth... & Electronics, an operator of Foreign-Trade Zone 196, has requested processing authority within FTZ 196 in Fort...
ELECTRONIC TECHNICIAN PERSONNEL AND TRAINING NEEDS OF IOWA INDUSTRIES.
ERIC Educational Resources Information Center
WEEDE, GARY DEAN
THE PURPOSE OF THIS STUDY WAS TO PROVIDE DATA FOR USE IN DEVELOPING OR IMPROVING ELECTRONIC TECHNOLOGY PROGRAMS. A POSTAL CARD QUESTIONNAIRE WAS SENT TO 678 MANUFACTURING AND PROCESSING INDUSTRIES IN IOWA EMPLOYING MORE THAN 50 PERSONS AND ALL ELECTRICAL, ELECTRONIC, AND PRECISION INSTRUMENT MANUFACTURERS EMPLOYING FEWER THAN 50 PERSONS. DATA WERE…
Safety of railroad employees' use of personal electronic devices
DOT National Transportation Integrated Search
2014-06-01
This report describes two studies sponsored by the Federal Railroad Administration that examined distraction from personal electronic device (PED) usage among safety-critical railroad employees. Study I considered railroad rules, railroad efficiency ...
Misson-Yates, S; Gonzalez, R; McGovern, M; Greener, A
2015-05-01
This article describes the external audit measurements conducted in two UK centres implementing total skin electron beam therapy (TSEBT) and the results obtained. Measurements of output, energy, beam flatness and symmetry at a standard distance (95 or 100 cm SSD) were performed using a parallel plate chamber in solid water. Similarly, output and energy measurements were also performed at the treatment plane for single and dual fields. Clinical simulations were carried out using thermoluminescent dosemeters (TLDs) and Gafchromic® film (International Specialty Products, Wayne, NJ) on an anthropomorphic phantom. Extended distance measurements confirmed that local values for the beam dosimetry at Centres A and B were within 2% for outputs and 1-mm agreement of the expected depth at which the dose is 50% of the maximum for the depth-dose curve in water (R50,D) value. Clinical simulation using TLDs) showed an agreement of -1.6% and -6.7% compared with the expected mean trunk dose for each centre, respectively, and a variation within 10% (±1 standard deviation) across the trunk. The film results confirmed that the delivery of the treatment technique at each audited centre complies with the European Organisation for Research and Treatment of Cancer recommendations. This audit methodology has proven to be a successful way to confirm the agreement of dosimetric parameters for TSEBT treatments at both audited centres and could serve as the basis for an audit template to be used by other audit groups. TSEBT audits are not established in the UK owing to a limited number of centres carrying out the treatment technique. This article describes the audits performed at two UK centres prior to their clinical implementation.
Gonzalez, R; McGovern, M; Greener, A
2015-01-01
Objective: This article describes the external audit measurements conducted in two UK centres implementing total skin electron beam therapy (TSEBT) and the results obtained. Methods: Measurements of output, energy, beam flatness and symmetry at a standard distance (95 or 100 cm SSD) were performed using a parallel plate chamber in solid water. Similarly, output and energy measurements were also performed at the treatment plane for single and dual fields. Clinical simulations were carried out using thermoluminescent dosemeters (TLDs) and Gafchromic® film (International Specialty Products, Wayne, NJ) on an anthropomorphic phantom. Results: Extended distance measurements confirmed that local values for the beam dosimetry at Centres A and B were within 2% for outputs and 1-mm agreement of the expected depth at which the dose is 50% of the maximum for the depth–dose curve in water (R50,D) value. Clinical simulation using TLDs) showed an agreement of −1.6% and −6.7% compared with the expected mean trunk dose for each centre, respectively, and a variation within 10% (±1 standard deviation) across the trunk. The film results confirmed that the delivery of the treatment technique at each audited centre complies with the European Organisation for Research and Treatment of Cancer recommendations. Conclusion: This audit methodology has proven to be a successful way to confirm the agreement of dosimetric parameters for TSEBT treatments at both audited centres and could serve as the basis for an audit template to be used by other audit groups. Advances in knowledge: TSEBT audits are not established in the UK owing to a limited number of centres carrying out the treatment technique. This article describes the audits performed at two UK centres prior to their clinical implementation. PMID:25761213
Recent Progress of Self-Powered Sensing Systems for Wearable Electronics.
Lou, Zheng; Li, La; Wang, Lili; Shen, Guozhen
2017-12-01
Wearable/flexible electronic sensing systems are considered to be one of the key technologies in the next generation of smart personal electronics. To realize personal portable devices with mobile electronics application, i.e., wearable electronic sensors that can work sustainably and continuously without an external power supply are highly desired. The recent progress and advantages of wearable self-powered electronic sensing systems for mobile or personal attachable health monitoring applications are presented. An overview of various types of wearable electronic sensors, including flexible tactile sensors, wearable image sensor array, biological and chemical sensor, temperature sensors, and multifunctional integrated sensing systems is provided. Self-powered sensing systems with integrated energy units are then discussed, separated as energy harvesting self-powered sensing systems, energy storage integrated sensing systems, and all-in-on integrated sensing systems. Finally, the future perspectives of self-powered sensing systems for wearable electronics are discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Zheng, Yi; He, Zhi-Zhu; Yang, Jun; Liu, Jing
2014-04-01
Printed electronics is becoming increasingly important in a variety of newly emerging areas. However, restricted to the rather limited conductive inks and available printing strategies, the current electronics manufacture is usually confined to industry level. Here, we show a highly cost-effective and entirely automatic printing way towards personal electronics making, through introducing a tapping-mode composite fluid delivery system. Fundamental mechanisms regarding the reliable printing, transfer and adhesion of the liquid metal inks on the substrate were disclosed through systematic theoretical interpretation and experimental measurements. With this liquid metal printer, a series of representative electronic patterns spanning from single wires to desired complex configurations such as integrated circuit (IC), printed-circuits-on-board (PCB), electronic paintings, or more do-it-yourself (DIY) devices, were demonstrated to be printed out with high precision in a moment. And the total machine cost already reached personally affordable price. This is hard to achieve by a conventional PCB technology which generally takes long time and is material, water and energy consuming, while the existing printed electronics is still far away from the real direct printing goal. The present work opens the way for large scale personal electronics manufacture and is expected to generate important value for the coming society.
Zheng, Yi; He, Zhi-Zhu; Yang, Jun; Liu, Jing
2014-04-04
Printed electronics is becoming increasingly important in a variety of newly emerging areas. However, restricted to the rather limited conductive inks and available printing strategies, the current electronics manufacture is usually confined to industry level. Here, we show a highly cost-effective and entirely automatic printing way towards personal electronics making, through introducing a tapping-mode composite fluid delivery system. Fundamental mechanisms regarding the reliable printing, transfer and adhesion of the liquid metal inks on the substrate were disclosed through systematic theoretical interpretation and experimental measurements. With this liquid metal printer, a series of representative electronic patterns spanning from single wires to desired complex configurations such as integrated circuit (IC), printed-circuits-on-board (PCB), electronic paintings, or more do-it-yourself (DIY) devices, were demonstrated to be printed out with high precision in a moment. And the total machine cost already reached personally affordable price. This is hard to achieve by a conventional PCB technology which generally takes long time and is material, water and energy consuming, while the existing printed electronics is still far away from the real direct printing goal. The present work opens the way for large scale personal electronics manufacture and is expected to generate important value for the coming society.
Zheng, Yi; He, Zhi-Zhu; Yang, Jun; Liu, Jing
2014-01-01
Printed electronics is becoming increasingly important in a variety of newly emerging areas. However, restricted to the rather limited conductive inks and available printing strategies, the current electronics manufacture is usually confined to industry level. Here, we show a highly cost-effective and entirely automatic printing way towards personal electronics making, through introducing a tapping-mode composite fluid delivery system. Fundamental mechanisms regarding the reliable printing, transfer and adhesion of the liquid metal inks on the substrate were disclosed through systematic theoretical interpretation and experimental measurements. With this liquid metal printer, a series of representative electronic patterns spanning from single wires to desired complex configurations such as integrated circuit (IC), printed-circuits-on-board (PCB), electronic paintings, or more do-it-yourself (DIY) devices, were demonstrated to be printed out with high precision in a moment. And the total machine cost already reached personally affordable price. This is hard to achieve by a conventional PCB technology which generally takes long time and is material, water and energy consuming, while the existing printed electronics is still far away from the real direct printing goal. The present work opens the way for large scale personal electronics manufacture and is expected to generate important value for the coming society. PMID:24699375
Guide to the NITRD Program FY 2004-FY 2005. Supplement to the President’s Budget for FY 2005
2004-12-01
electronic medical records systems . At the core of such systems is the concept of a secure, patient-centered electronic health record ( EHR ) that: 1...support the development of an NHII that includes an Electronic Health Record System ( EHRS ). The EHRS will be a longitudinal collection of electronic... health information for and about persons. It will allow electronic access to person- and population-level information by authorized users. The system
21 CFR 1305.06 - Persons entitled to fill orders for Schedule I and II controlled substances.
Code of Federal Regulations, 2013 CFR
2013-04-01
... either a DEA Form 222 or an electronic order may return the substance to the supplier of the substance with either a DEA Form 222 or an electronic order from the supplier. (c) A person registered to... person registered or authorized to conduct chemical analysis or research with controlled substances may...
21 CFR 1305.06 - Persons entitled to fill orders for Schedule I and II controlled substances.
Code of Federal Regulations, 2014 CFR
2014-04-01
... either a DEA Form 222 or an electronic order may return the substance to the supplier of the substance with either a DEA Form 222 or an electronic order from the supplier. (c) A person registered to... person registered or authorized to conduct chemical analysis or research with controlled substances may...
21 CFR 1305.06 - Persons entitled to fill orders for Schedule I and II controlled substances.
Code of Federal Regulations, 2012 CFR
2012-04-01
... either a DEA Form 222 or an electronic order may return the substance to the supplier of the substance with either a DEA Form 222 or an electronic order from the supplier. (c) A person registered to... person registered or authorized to conduct chemical analysis or research with controlled substances may...
Ohman, A; Kull, L; Andersson, J; Flygare, L
2008-12-01
To measure organ doses and calculate effective doses for pre-operative radiographic examination of lower third molars with CT and conventional radiography (CR). Measurements of organ doses were made on an anthropomorphic head phantom with lithium fluoride thermoluminescent dosemeters. The dosemeters were placed in regions corresponding to parotid and submandibular glands, mandibular bone, thyroid gland, skin, eye lenses and brain. The organ doses were used for the calculation of effective doses according to proposed International Commission on Radiological Protection 2005 guidelines. For the CT examination, a Siemens Somatom Plus 4 Volume Zoom was used and exposure factors were set to 120 kV and 100 mAs. For conventional radiographs, a Scanora unit was used and panoramic, posteroanterior, stereographic (scanogram) and conventional spiral tomographic views were exposed. The effective doses were 0.25 mSv, 0.060 mSv and 0.093 mSv for CT, CR without conventional tomography and CR with conventional spiral tomography, respectively. The effective dose is low when CT examination with exposure factors optimized for the examination of bone structures is performed. However, the dose is still about four times as high as for CR without tomography. CT should therefore not be a standard method for the examination of lower third molars. In cases where there is a close relationship between the tooth and the inferior alveolar nerve the advantages of true sectional imaging, such as CT, outweighs the higher effective dose and is recommended. Further reduction in the dose is feasible with further optimization of examination protocols and the development of newer techniques.
Pradhan, A S; Bakshi, A K
2002-01-01
CaSO4:Dy and LiF TLDs do not exhibit photon energy dependence beyond +/-55% for photons in the energy range from 1 MeV to about 7 MeV. However, when sandwiched between metal filters or used in TLD badge holders having metal filters, the response changes for irradiation from high energy photons as compared to that from 60Co gamma rays (generally used for reference calibrations). This effect is about the same for both the lower atomic number TLD (LiF) and higher atomic number TLD (CaSO4:Dy). For TLDs held on the surface of the phantom and irradiated in collimated photon beams, the response of TLDs without any filter or those under the open window of the TLD badge is considerably reduced due to insufficient build-up to high energy photons, whereas for uncollimated radiation fields from power reactors, an over-response is observed. It is observed that the use of inappropriate encapsulation of dosemeters would cause a significant error not only in the estimation of doses due to penetrating radiations but also in the estimation of beta doses in the mixed fields of beta radiation, high energy gamma rays and high energy electrons often encountered in the fields of pressurised heavy water reactors.
Personal Electronic Aid for Maintenance
1989-03-01
as input to the Department of Defense Computer -Aided Acquisi- tion and Logistics Support program and to the development of the Militarized Electronic...NUMBER ORGANIZATION (If applicable) Bc. ADDRESS (City, State, and ZIP Code) 10. SOURCE OF FUNDING NUMBERS PROGRAM PROJECT TASK WORK UNIT ELEMENT NO. NO...Manpower and Training Technology Development Program . This summary report of the Personal Electronic Aid for Maintenance (PEAM) was prepared by the
Characterising Passive Dosemeters for Dosimetry of Biological Experiments in Space (dobies)
NASA Astrophysics Data System (ADS)
Vanhavere, Filip; Spurny, Frantisek; Yukihara, Eduardo; Genicot, Jean-Louis
Introduction: The DOBIES (Dosimetry of biological experi-ments in space) project focusses on the use of a stan-dard dosimetric method (as a combination of differ-ent passive techniques) to measure accurately the absorbed doses and equivalent doses in biological samples. Dose measurements on biological samples are of high interest in the fields of radiobiology and exobiology. Radiation doses absorbed by biological samples must be quantified to be able to determine the relationship between observed biological effects and the radiation dose. The radiation field in space is very complex, con-sisting of protons, neutrons, electrons and high-energy heavy charged particles. It is not straightfor-ward to measure doses in this radiation field, cer-tainly not with only small and light passive doseme-ters. The properties of the passive detectors must be tested in radiation fields that are representative of the space radiation. We will report on the characterisation of different type of passive detectors at high energy fields. The results from such characterisation measurements will be applied to recent exposures of detectors on the International Space Station. Material and methods: Following passive detectors are used: • thermoluminescent detectors (TLD) • optically stimulated luminescence detectors (OSLD) • track etch detectors (TED) The different groups have participated in the past to the ICCHIBAN series of irradiations. Here protons and other particles of high energy were used to de-termine the LET-dependency of the passive detec-tors. The last few months, new irradiations have been done at the iThemba labs (100-200 MeV protons), Dubna (145 MeV protons) and the JRC-IRMM (quasi mono energetic neutrons up to 19 MeV). All these detectors were also exposed to a simulated space radiation field at CERN (CERF-field). Discussion: The interpretation of the TLD and OSLD results is done using the measured LET spectrum (TED) and the LET-dependency curves of ths TLD and OSLDs. These LET- dependency curves are determined based on the different irradiations listed above. We will report on the results of the different detectors in these fields. Further information on the LET of the space irradia-tion can be deduced from the ratio of the different peaks of the TLDs after glow curve deconvolution, and from the shape of the decay curve of the OSLDs. The results in the CERF field can on the other hand directly being used as a calibration for space radia-tion fields. Conclusion: Combining different passive detectors will lead to improved information on the radiation field, and thus to a better estimation of the absorbed dose to the bio-logical samples. We use the characterisations on high energy accelerators to improve the estimation of some recent space doses.
Utilizing Technology to Enhance Learning Environments: The Net Gen Student
ERIC Educational Resources Information Center
Muhammad, Amanda J.; Mitova, Mariana A.; Wooldridge, Deborah G.
2016-01-01
It is essential for instructors to understand the importance of classroom technology so they can prepare to use it to personalize students' learning. Strategies for choosing effective electronic tools are presented, followed by specific suggestions for designing enhanced personalized learning using electronic tools.
Electronic Travel Aids for Blind Persons.
ERIC Educational Resources Information Center
Hill, Everett W.; Bradfield, Anna L.
1984-01-01
The article describes application for visually impaired persons of widely used Electronic Travel Aids--the Lindsay Russell Pathsounder, the Mowat Sensor, the Sonicguide, and the C-5 Laser Cane. In addition, a research review provides insight into the issues affecting future use of the devices. (Author/CL)
Rose, Carol Dawson; Johnson, Mallory; Janson, Susan L.
2015-01-01
The HITECH Act signed into law in 2009 requires hospitals to provide patients with electronic access to their health information through an electronic personal health record (ePHR) in order to receive Medicare/Medicaid incentive payments. Little is known about who uses these systems or the impact these systems will have on patient outcomes in HIV care. The health care empowerment model provides rationale for the hypothesis that knowledge from an electronic personal health record can lead to greater patient empowerment resulting in improved outcomes. The objective was to determine the patient characteristics and patient activation, empowerment, satisfaction, knowledge of their CD4, Viral Loads, and antiretroviral medication, and medication adherence outcomes associated with electronic personal health record use in Veterans living with HIV at the San Francisco VA Medical Center. The participants included HIV-Infected Veterans receiving care in a low volume HIV-clinic at the San Francisco VA Medical Center, divided into two groups of users and non-users of electronic personal health records. The research was conducted using in-person surveys either online or on paper and data abstraction from medical records for current anti-retroviral therapy (ART), CD4 count, and plasma HIV-1 viral load. The measures included the Patient Activation Measure, Health Care Empowerment Inventory, ART adherence, provider satisfaction, current CD4 count, current plasma viral load, knowledge of current ART, knowledge of CD4 counts, and knowledge of viral load. In all, 40 participants were recruited. The use of electronic personal health records was associated with significantly higher levels of patient activation and levels of patient satisfaction for getting timely appointments, care, and information. ePHR was also associated with greater proportions of undetectable plasma HIV-1 viral loads, of knowledge of current CD4 count, and of knowledge of current viral load. The two groups differed by race and computer access. There was no difference in the current CD4, provider satisfaction, Health Care Empowerment Inventory score, satisfaction with provider-patient communication, satisfaction with courteous and helpful staff, knowledge of ART, or ART adherence. The use of electronic personal health records is associated with positive clinical and behavioral characteristics. The use of these systems may play a role in improving the health of people with HIV. Larger studies are needed to further evaluate these associations. PMID:25802815
Wouters, Hans; Amin, Darya F H; Taxis, Katja; Heerdink, Eibert R; Egberts, Antoine C G; Gardarsdottir, Helga
2016-10-01
Treatment with antidepressants is often compromised by substantial nonadherence. To understand nonadherence, specific medication-related behaviors and beliefs have been studied, but less is known about broader and temporally stable personality "traits." Furthermore, adherence has often been assessed by a single method. Hence, we investigated associations between the Big Five personality traits and adherence assessed by self-report, electronic drug use monitoring, and dispensing data. Using the Big Five Inventory, we assessed the personality traits "openness," "conscientiousness," "extraversion," "agreeableness," and "neuroticism" of patients treated with antidepressants who were invited through community pharmacies. Self-reported adherence was assessed with the Medication Adherence Rating Scale (score >24), electronic monitoring with medication event monitoring system (MEMS) devices (therapy days missed ≤ 10% and < 4 consecutive days missed), and dispensing data (medication possession ratio ≥ 80%). One hundred four women and 33 men participated (mean age, 51; standard deviation, 14). Paroxetine was most frequently prescribed (N = 53, 38%). Logistic regression analysis revealed that of the personality traits, the third and fourth quartiles of "conscientiousness" were associated with better self-reported adherence (odds ratio, 3.63; 95% confidence interval, 1.34-9.86 and odds ratio, 2.97; 95% confidence interval, 1.09-8.08; P ≤ 0.05). No relationships were found between personality traits and adherence assessed through electronic drug use monitoring or dispensing data. We therefore conclude that adherence to antidepressant therapy seems to be largely unrelated to personality traits.
Eye doses to staff in a nuclear medicine department.
Summers, Elizabeth C; Brown, Janis L E; Bownes, Peter J; Anderson, Shona E
2012-05-01
Occupational radiation doses to the Nuclear Medicine Department staff at Mount Vernon Hospital are routinely measured using optically stimulated luminescence dosemeters for whole-body effective dose and ring thermoluminescence dosemeters (TLDs) for finger dose. In 2002, a project was carried out using LiF:Mg,Cu,P Chinese TLDs to measure the dose to the lens of the eye received by staff during normal working procedures. Separate pairs of TLDs were worn by staff on their forehead between their eyes while dispensing and releasing in the radiopharmacy, injecting, and when administering I-131 capsules to patients. The dose received was calculated using calibration data from identical TLDs irradiated with Tc-99m, I-131, and the Ir-192 source of a Gammamed High Dose Rate (HDR) treatment unit. Data were collected over a 5-month period and the mean dose to the eye was calculated for each procedure. Using a typical yearly workload, the annual dose to the eye for a single member of staff was calculated and found to be 4.5 mSv. The occupational eye dose limit was, at the time, 150 mSv; therefore, staff were well below the level (3/10th of this limit) that would have required them to be classified. However, there have been large increases in radiopharmacy production and I-131 therapies administered at Mount Vernon in subsequent years. It is therefore expected that the eye dose received by staff will have increased to be significantly higher than 4.5 mSv and will in fact be greater than 6 mSv, which is 3/10th of the proposed new dose limit and would require these staff to become classified workers.
Eye lens dose in interventional cardiology.
Principi, S; Delgado Soler, C; Ginjaume, M; Beltran Vilagrasa, M; Rovira Escutia, J J; Duch, M A
2015-07-01
The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y(-1), averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y(-1). This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y(-1). Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y(-1). It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Jafari, Shakardokht M; Jordan, Tom J; Distefano, Gail; Bradley, David A; Spyrou, Nicholas M; Nisbet, Andrew; Clark, Catharine H
2015-01-01
To investigate the feasibility of using glass beads as novel thermoluminescent dosemeters (TLDs) for radiotherapy treatment plan verification. Commercially available glass beads with a size of 1-mm thickness and 2-mm diameter were characterized as TLDs. Five clinical treatment plans including a conventional larynx, a conformal prostate, an intensity-modulated radiotherapy (IMRT) prostate and two stereotactic body radiation therapy (SBRT) lung plans were transferred onto a CT scan of a water-equivalent phantom (Solid Water(®), Gammex, Middleton, WI) and the dose distribution recalculated. The number of monitor units was maintained from the clinical plan and delivered accordingly. The doses determined by the glass beads were compared with those measured by a graphite-walled ionization chamber, and the respective expected doses were determined by the treatment-planning system (TPS) calculation. The mean percentage difference between measured dose with the glass beads and TPS was found to be 0.3%, -0.1%, 0.4%, 1.8% and 1.7% for the conventional larynx, conformal prostate, IMRT prostate and each of the SBRT delivery techniques, respectively. The percentage difference between measured dose with the ionization chamber and glass bead was found to be -1.2%, -1.4%, -0.1%, -0.9% and 2.4% for the above-mentioned plans, respectively. The results of measured doses with the glass beads and ionization chamber in comparison with expected doses from the TPS were analysed using a two-sided paired t-test, and there was no significant difference at p < 0.05. It is feasible to use glass-bead TLDs as dosemeters in a range of clinical plan verifications. Commercial glass beads are utilized as low-cost novel TLDs for treatment-plan verification.
NASA Astrophysics Data System (ADS)
Villarreal-Barajas, J. E.; Piccinini, M.; Vincenti, M. A.; Bonfigli, F.; Khan, R. F.; Montereali, R. M.
2015-04-01
Among insulating materials, lithium fluoride (LiF) has been successfully used as ionizing radiation dosemeter for more than 60 years. Thermoluminescence (TL) has been the most commonly used reading technique to evaluate the absorbed dose. Lately, optically stimulated luminescence (OSL) of visible emitting color centers (CCs) has also been explored in pure and doped LiF. This work focuses on the experimental behaviour of nominally pure LiF crystals dosemeters for 6 MV x rays at low doses based on photoluminescence (PL) of radiation induced CCs. Polished LiF crystals were irradiated using 6 MV x rays produced by a clinical linear accelerator. The doses (absorbed dose to water) covered the 1-100 Gy range. Optical absorption spectra show stable formation of primary F defects up to a maximum concentration of 2×1016 cm-3, while no significant M absorption band at around 450 nm was detected. On the other hand, under Argon laser excitation at 458 nm, PL spectra of the irradiated LiF crystals clearly exhibited the characteristic F2 and F+3 visible broad emission bands. Their sum intensity is linearly proportional to the absorbed dose in the investigated range. PL integrated intensity was also measured using a conventional fluorescence optical microscope under blue lamp illumination. The relationship between the absorbed dose and the integrated F2 and F+3 PL intensities, represented by the net average pixel number in the optical fluorescence images, is also fairly linear. Even at the low point defect densities obtained at the investigated doses, these preliminary experimental results are encouraging for further investigation of CCs PL in LiF crystals for clinical dosimetry.
A SHORT HISTORY AND CRITICAL REVIEW OF INDIVIDUAL MONITORING.
Wernli, Christian
2016-09-01
Soon after the discovery of X-rays and the radioactive element radium harmful radiation effects occurred, mainly in the medical field. Consequently, the radiologists, a new profession at that time, called for a limitation of radiation exposures. First proposals were to limit the exposure rate to prevent the incidence of skin erythema. It took more than two decades and there were many victims of severe radiation effects until a sound basis for radiation protection and individual monitoring was established. For external dosimetry, the film dosemeter was invented in the 1920s. This device, often combined with an ion chamber-based pencil dosemeter, dominated the systems used in personnel dosimetry until the end of the twentieth century. For internal exposure, the concept of limiting the 'body burden' was commonly used, and only in the late 1970s, the new concept of the 'effective dose equivalent' published in ICRP publication 26 allowed for a unified interpretation and, therefore, addition of the dosimetric quantities for external and internal exposures. By the end of the last century, individual monitoring had to survive an inflation of proposals for new quantities, but fortunately, it was also the time of vast developments of new technologies, methods and procedures. Later on, much room was given to highly sophisticated regulations, requirements, metrological concepts and administrative procedures. In this complex environment, the original task of individual monitoring became more and more hidden behind secondary loads. Now, like about hundred years ago, however with different motivation, once again the ultimate goal of the professional work has to be thought about by asking: Do people always know why they do what they do? Or simply: Why individual monitoring? © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Downing, Gregory J; Boyle, Scott N; Brinner, Kristin M; Osheroff, Jerome A
2009-10-08
Advances in technology and the scientific understanding of disease processes are presenting new opportunities to improve health through individualized approaches to patient management referred to as personalized medicine. Future health care strategies that deploy genomic technologies and molecular therapies will bring opportunities to prevent, predict, and pre-empt disease processes but will be dependent on knowledge management capabilities for health care providers that are not currently available. A key cornerstone to the potential application of this knowledge will be effective use of electronic health records. In particular, appropriate clinical use of genomic test results and molecularly-targeted therapies present important challenges in patient management that can be effectively addressed using electronic clinical decision support technologies. Approaches to shaping future health information needs for personalized medicine were undertaken by a work group of the American Health Information Community. A needs assessment for clinical decision support in electronic health record systems to support personalized medical practices was conducted to guide health future development activities. Further, a suggested action plan was developed for government, researchers and research institutions, developers of electronic information tools (including clinical guidelines, and quality measures), and standards development organizations to meet the needs for personalized approaches to medical practice. In this article, we focus these activities on stakeholder organizations as an operational framework to help identify and coordinate needs and opportunities for clinical decision support tools to enable personalized medicine. This perspective addresses conceptual approaches that can be undertaken to develop and apply clinical decision support in electronic health record systems to achieve personalized medical care. In addition, to represent meaningful benefits to personalized decision-making, a comparison of current and future applications of clinical decision support to enable individualized medical treatment plans is presented. If clinical decision support tools are to impact outcomes in a clear and positive manner, their development and deployment must therefore consider the needs of the providers, including specific practice needs, information workflow, and practice environment.
2009-01-01
Background Advances in technology and the scientific understanding of disease processes are presenting new opportunities to improve health through individualized approaches to patient management referred to as personalized medicine. Future health care strategies that deploy genomic technologies and molecular therapies will bring opportunities to prevent, predict, and pre-empt disease processes but will be dependent on knowledge management capabilities for health care providers that are not currently available. A key cornerstone to the potential application of this knowledge will be effective use of electronic health records. In particular, appropriate clinical use of genomic test results and molecularly-targeted therapies present important challenges in patient management that can be effectively addressed using electronic clinical decision support technologies. Discussion Approaches to shaping future health information needs for personalized medicine were undertaken by a work group of the American Health Information Community. A needs assessment for clinical decision support in electronic health record systems to support personalized medical practices was conducted to guide health future development activities. Further, a suggested action plan was developed for government, researchers and research institutions, developers of electronic information tools (including clinical guidelines, and quality measures), and standards development organizations to meet the needs for personalized approaches to medical practice. In this article, we focus these activities on stakeholder organizations as an operational framework to help identify and coordinate needs and opportunities for clinical decision support tools to enable personalized medicine. Summary This perspective addresses conceptual approaches that can be undertaken to develop and apply clinical decision support in electronic health record systems to achieve personalized medical care. In addition, to represent meaningful benefits to personalized decision-making, a comparison of current and future applications of clinical decision support to enable individualized medical treatment plans is presented. If clinical decision support tools are to impact outcomes in a clear and positive manner, their development and deployment must therefore consider the needs of the providers, including specific practice needs, information workflow, and practice environment. PMID:19814826
10 CFR 34.89 - Location of documents and records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... problems identified in daily checks of equipment as required by § 34.73(a); (5) Records of alarm system and... as pocket dosimeter and/or electronic personal dosimeters readings as required by § 34.83; (7... calibrations of alarm ratemeters and operability checks of pocket dosimeters and/or electronic personal...
10 CFR 34.89 - Location of documents and records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... problems identified in daily checks of equipment as required by § 34.73(a); (5) Records of alarm system and... as pocket dosimeter and/or electronic personal dosimeters readings as required by § 34.83; (7... calibrations of alarm ratemeters and operability checks of pocket dosimeters and/or electronic personal...
Weksler, Marc E; Weksler, Babette B
2012-01-01
Multitasking is a rapidly growing phenomenon affecting all segments of the population but is rarely as successful as its proponents believe. The use of mobile electronic devices contributes importantly to multitasking and cognitive overload. Although personal electronic devices provide many benefits, their adverse effects are frequently overlooked. Personal observation and a review of the scientific literature supports the view that overuse or misuse of personal electronic devices promotes cognitive overload, impairs multitasking and lowers performance at all ages but particularly in the elderly. This phenomenon appears to be rapidly increasing and threatens to become a tsunami as spreading electronic waves cause an 'epidemic of distraction'. Mobile electronic devices often bring benefits to their users in terms of rapid access to information. However, there is a dark side to the increasing addiction to these devices that challenges the health and well-being of the entire population, targeting, in particular, the aged and infirm. New approaches to information gathering can foster creativity if cognitive overload is avoided. Copyright © 2012 S. Karger AG, Basel.
ERIC Educational Resources Information Center
Hines, Denise Williams
2009-01-01
The use of electronic personal health records is becoming increasingly more popular as healthcare providers, healthcare and government leaders, and patients are seeking ways to improve healthcare quality and to decrease costs (Abrahamsen, 2007). This quantitative, descriptive correlational study examined the relationship between the degree of…
Inventory of Electronic Mobility Aids for Persons with Visual Impairments: A Literature Review
ERIC Educational Resources Information Center
Roentgen, Uta R.; Gelderblom, Gert Jan; Soede, Mathijs; de Witte, Luc P.
2008-01-01
This literature review of existing electronic mobility aids for persons who are visually impaired and recent developments in this field identified and classified 146 products, systems, and devices. The 21 that are currently available that can be used without environmental adaptation are described in functional terms. (Contains 2 tables.)
Know me - a journey in creating a personal electronic health record.
Buckley, Amanda; Fox, Suzanne
2015-01-01
KnowMe is a patient created personal story of key life events both medical and non-medical that enables clinicians to understand what matters to the patient, not what's the matter with them. By shifting the Electronic Health Record (EHR) focus to knowing when a patient was at their best, what's important to them, their personal health goals, and care preferences, clinicians and patients can collaboratively work together in creating a treatment plan that aligns resources tailored to the their needs.
Development of a framework of quality assurance practices for a radon passive dosemeter service.
D'Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M
2010-06-01
Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.
Long term performance of wearable transducer for motion energy harvesting
NASA Astrophysics Data System (ADS)
McGarry, Scott A.; Behrens, Sam
2010-04-01
Personal electronic devices such as cell phones, GPS and MP3 players have traditionally depended on battery energy storage technologies for operation. By harvesting energy from a person's motion, these devices may achieve greater run times without increasing the mass or volume of the electronic device. Through the use of a flexible piezoelectric transducer such as poly-vinylidene fluoride (PVDF), and integrating it into a person's clothing, it becomes a 'wearable transducer'. As the PVDF transducer is strained during the person's routine activities, it produces an electrical charge which can then be harvested to power personal electronic devices. Existing wearable transducers have shown great promise for personal motion energy harvesting applications. However, they are presently physically bulky and not ergonomic for the wearer. In addition, there is limited information on the energy harvesting performance for wearable transducers, especially under realistic conditions and for extended cyclic force operations - as would be experienced when worn. In this paper, we present experimental results for a wearable PVDF transducer using a person's measured walking force profile, which is then cycled for a prolonged period of time using an experimental apparatus. Experimental results indicate that after an initial drop in performance, the transducer energy harvesting performance does not substantially deteriorate over time, as less than 10% degradation was observed. Longevity testing is still continuing at CSIRO.
Downs, Nathan J.; Parisi, Alfio V.; Butler, Harry; Rawlings, Alex; Elrahoumi, Raja Salem
2017-01-01
Exposure to natural sunlight, specifically solar ultraviolet (UV) radiation contributes to lifetime risks of skin cancer, eye disease, and diseases associated with vitamin D insufficiency. Improved knowledge of personal sun exposure patterns can inform public health policy; and help target high-risk population groups. Subsequently, an extensive number of studies have been conducted to measure personal solar UV exposure in a variety of settings. Many of these studies, however, use digital or paper-based journals (self-reported volunteer recall), or employ cost prohibitive electronic UV dosimeters (that limit the size of sample populations), to estimate periods of exposure. A cost effective personal electronic sun journal (ESJ) built from readily available infrared photodiodes is presented in this research. The ESJ can be used to complement traditional UV dosimeters that measure total biologically effective exposure by providing a time-stamped sun exposure record. The ESJ can be easily attached to clothing and data logged to personal devices (including fitness monitors or smartphones). The ESJ improves upon self-reported exposure recording and is a cost effective high-temporal resolution option for monitoring personal sun exposure behavior in large population studies. PMID:29201865
ERIC Educational Resources Information Center
Mechling, Linda C.
2011-01-01
Use of portable electronic devices by persons with moderate intellectual disabilities and autism spectrum disorders is gaining increased research attention. The purpose of this review was to synthesize twenty-first century literature (2000-2010) focusing on these technologies. Twenty-one studies were identified which evaluated use of: (a) handheld…
Study of the impact of artificial articulations on the dose distribution under medical irradiation
NASA Astrophysics Data System (ADS)
Buffard, E.; Gschwind, R.; Makovicka, L.; Martin, E.; Meunier, C.; David, C.
2005-02-01
Perturbations due to the presence of high density heterogeneities in the body are not correctly taken into account in the Treatment Planning Systems currently available for external radiotherapy. For this reason, the accuracy of the dose distribution calculations has to be improved by using Monte Carlo simulations. In a previous study, we established a theoretical model by using the Monte Carlo code EGSnrc [I. Kawrakow, D.W.O. Rogers, The EGSnrc code system: MC simulation of electron and photon transport. Technical Report PIRS-701, NRCC, Ottawa, Canada, 2000] in order to obtain the dose distributions around simple heterogeneities. These simulations were then validated by experimental results obtained with thermoluminescent dosemeters and an ionisation chamber. The influence of samples composed of hip prostheses materials (titanium alloy and steel) and a substitute of bone were notably studied. A more complex model was then developed with the Monte Carlo code BEAMnrc [D.W.O. Rogers, C.M. MA, G.X. Ding, B. Walters, D. Sheikh-Bagheri, G.G. Zhang, BEAMnrc Users Manual. NRC Report PPIRS 509(a) rev F, 2001] in order to take into account the hip prosthesis geometry. The simulation results were compared to experimental measurements performed in a water phantom, in the case of a standard treatment of a pelvic cancer for one of the beams passing through the implant. These results have shown the great influence of the prostheses on the dose distribution.
78 FR 2912 - Prohibition on Personal Use of Electronic Devices on the Flight Deck
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-15
....C. 332(c)(7)(C)(i). In general, wireless telecommunications is the transfer of information between... personal wireless communications device or laptop computer for personal use while at their duty station on.... Personal Wireless Communications Device IV. Regulatory Notices and Analyses A. Regulatory Evaluation B...
Electronic Mail, a New Written-Language Register: A Study with French-Speaking Adolescents
ERIC Educational Resources Information Center
Volckaert-Legrier, Olga; Bernicot, Josie; Bert-Erboul, Alain
2009-01-01
The aim of this study was to determine the extent to which the linguistic forms used by adolescents in electronic mail (e-mail) differ from those used in standard written language. The study was conducted in French, a language with a deep orthography that has strict, addressee-dependent rules for using second person personal pronouns (unfamiliar…
27 CFR 73.33 - Am I legally bound by a form I sign electronically?
Code of Federal Regulations, 2010 CFR
2010-04-01
... TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURES AND PRACTICES ELECTRONIC SIGNATURES; ELECTRONIC SUBMISSION OF FORMS Electronic Filing of Documents with TTB § 73.33 Am I legally bound... paper document submitted to satisfy the same reporting requirement. Persons using electronic signatures...
Lehnbom, E C; Douglas, H E; Makeham, M A B
2016-01-01
The uptake of the Personally Controlled Electronic Health Record (PCEHR) has been slowly building momentum in Australia. The purpose of the PCEHR is to collect clinically important information from multiple healthcare providers to provide a secure electronic record to patients and their authorised healthcare providers that will ultimately enhance the efficiency and effectiveness of healthcare delivery. Reasons for the slow uptake of the PCEHR and future directions to improve its usefulness is discussed later. © 2016 Royal Australasian College of Physicians.
iES - An Intelligent Electronic Sales Platform
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanton, V L; Korbe III, W; Gao, J G
Current e-commerce systems support online shopping based on electronic product catalogs. The major issues associated with catalog-based commerce systems are: difficulty in distinguishing one retailer from another, complex navigation with confusing links, and a lack of personalized service. This paper reports an intelligent solution to address these issues. Our solution will provide a more personalized sales experience through the use of a transaction-based knowledge model that includes both the rules used for reasoning as well as the corresponding actions. Based on this solution, we have developed an intelligent electronic sales platform that is supported by a framework which provides themore » desired personalization as well as extensibility and customization capabilities. This paper reports our design and development of this system and application examples.« less
[The personal computer as a rehabilitation aid for severely handicapped patients].
Fischbach, F
1994-02-01
The case example presented outlines the efforts of a quadriplegic young man who has succeeded in finding himself an occupational basis through training as an expert in electronic desktop publishing (DTP). Due to his severe mobility handicaps, computerized workstations for DTP training had been put up both in the training company and in his own home. These Desktop Publishing systems enable even very severely disabled persons to perform at a par with non-disabled persons. If this adapted workplace is connected to a communication network, the work results need not be delivered materially to the place where they are needed or further worked on, but can be dispatched electronically to the addressee. Communication networks enable the disabled person to easily exchange data with other workstations, or, through the use of modems to access the public telephone system, to send messages from his private environment (e.g., for sending fax messages or placing information in his partners' electronic mailboxes).
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
... to use over a long period of time. Electronic devices Some people who stutter use electronic devices to help control fluency. For example, one ... in unison with another person. In some people, electronic devices may help improve fluency in a relatively ...
Single event upsets in semiconductor devices induced by highly ionising particles.
Sannikov, A V
2004-01-01
A new model of single event upsets (SEUs), created in memory cells by heavy ions and high energy hadrons, has been developed. The model takes into account the spatial distribution of charge collection efficiency over the cell area not considered in previous approaches. Three-dimensional calculations made by the HADRON code have shown good agreement with experimental data for the energy dependence of proton SEU cross sections, sensitive depths and other SEU observables. The model is promising for prediction of SEU rates for memory chips exposed in space and in high-energy experiments as well as for the development of a high-energy neutron dosemeter based on the SEU effect.
Natural gamma radioactivity in the villages of Kanyakumari District, Tamil Nadu, India.
Padua, Jeni Chandar; Basil Rose, M R
2013-01-01
In situ radiometric survey carried out in 81 revenue villages of Kanyakumari District, Tamil Nadu, India, using a portable radiation dosemeter/detector, revealed the existence of radiation hotspots along the coastal belt. A close observation of the coastal villages specifically revealed high background radioactivity in 14 coastal villages. A very high intrinsic anomalous radioactivity of 41.03 μSv h(-1) was observed, in a famous tourist spot in the coastal belt of Kanyakumari District. This is the highest level of radiation registered in South India, which is extremely higher than the permissible world average and is suggestive of causing severe clinical problems on continuous and prolonged exposure.
Server-Based and Server-Less Byod Solutions to Support Electronic Learning
2016-06-01
Knowledge Online NSD National Security Directive OS operating system OWA Outlook Web Access PC personal computer PED personal electronic device PDA...mobile devices, institute mobile device policies and standards, and promote the development and use of DOD mobile and web -enabled applications” (DOD...with an isolated BYOD web server, properly educated system administrators must carry out and execute the necessary, pre-defined network security
75 FR 52513 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-26
... theater environmental monitoring data, personal protective equipment usage data, observation of work... change, including any personal identifiers or contact information. FOR FURTHER INFORMATION CONTACT: Ms...) Electronic Data Interchange Personal Identifier (EDIPI) of individuals. Authority for Maintenance of the...
12 CFR 1005.14 - Electronic fund transfer service provider not holding consumer's account.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 8 2012-01-01 2012-01-01 false Electronic fund transfer service provider not... PROTECTION ELECTRONIC FUND TRANSFERS (REGULATION E) § 1005.14 Electronic fund transfer service provider not holding consumer's account. (a) Provider of electronic fund transfer service. A person that provides an...
12 CFR 1005.14 - Electronic fund transfer service provider not holding consumer's account.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 8 2013-01-01 2013-01-01 false Electronic fund transfer service provider not... PROTECTION ELECTRONIC FUND TRANSFERS (REGULATION E) General § 1005.14 Electronic fund transfer service provider not holding consumer's account. (a) Provider of electronic fund transfer service. A person that...
12 CFR 1005.14 - Electronic fund transfer service provider not holding consumer's account.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 8 2014-01-01 2014-01-01 false Electronic fund transfer service provider not... PROTECTION ELECTRONIC FUND TRANSFERS (REGULATION E) General § 1005.14 Electronic fund transfer service provider not holding consumer's account. (a) Provider of electronic fund transfer service. A person that...
Designing an Electronic Personal Health Record for Professional Iranian Athletes
Abdolkhani, Robab; Halabchi, Farzin; Safdari, Reza; Dargahi, Hossein; Shadanfar, Kamran
2014-01-01
Background: By providing sports organizations with electronic records and instruments that can be accessed at any time or place, specialized care can be offered to athletes regardless of injury location, and this makes the follow-up from first aid through to full recovery more efficient. Objectives: The aim of this study was to develop an electronic personal health record for professional Iranian athletes. Patients and Methods: First, a comparative study was carried out on the types of professional athletes’existing handheld and electronic health information management systems currently being used in Iran and leading countries in the field of sports medicine including; Australia, Canada and the United States. Then a checklist was developed containing a minimum dataset of professional athletes’ personal health records and distributed to the people involved, who consisted of 50 specialists in sports medicine and health information management, using the Delphi method. Through the use of data obtained from this survey, a basic paper model of professional athletes' personal health record was constructed and then an electronic model was created accordingly. Results: Access to information in the electronic record was through a web-based, portal system. The capabilities of this system included: access to information at any time and location, increased interaction between the medical team, comprehensive reporting and effective management of injuries, flexibility and interaction with financial, radiology and laboratory information systems. Conclusions: It is suggested that a framework should be created to promote athletes’ medical knowledge and provide the education necessary to manage their information. This would lead to improved data quality and ultimately promote the health of community athletes. PMID:25741410
Consumers' Use of Personal Electronic Devices in the Kitchen.
Lando, Amy M; Bazaco, Michael C; Chen, Yi
2018-02-23
Smartphones, tablets, and other personal electronic devices have become ubiquitous in Americans' daily lives. These devices are used by people throughout the day, including while preparing food. For example, a device may be used to look at recipes and therefore be touched multiple times during food preparation. Previous research has indicated that cell phones can harbor bacteria, including opportunistic human pathogens such as Staphylococcus and Klebsiella spp. This investigation was conducted with data from the 2016 Food Safety Survey (FSS) and from subsequent focus groups to determine the frequency with which consumers use personal electronic devices in the kitchen while preparing food, the types of devices used, and hand washing behaviors after handling these devices. The 2016 FSS is the seventh wave of a repeated cross-sectional survey conducted by the U.S. Food and Drug Administration in collaboration with the U.S. Department of Agriculture. The goal of the FSS is to evaluate U.S. adult consumer attitudes, behaviors, and knowledge about food safety. The FSS included 4,169 adults that were contacted using a dual-frame (land line and cell phone interviews) random-digit-dial sampling process. The personal electronics module was the first of three food safety topics discussed by each of eight consumer focus groups, which were convened in four U.S. cities in fall 2016. Results from the 2016 FSS revealed that of those individuals who use personal electronic devices while cooking, only about one third reported washing hands after touching the device and before continuing cooking. This proportion is significantly lower than that for self-reported hand washing behaviors after touching risky food products such as raw eggs, meat, chicken, or fish. Results from the focus groups highlight the varied usage of these devices during food preparation and the related strategies consumers are using to incorporate personal electric devices into their cooking routines.
Magnetic Thin Films for Perpendicular Magnetic Recording Systems
NASA Astrophysics Data System (ADS)
Sugiyama, Atsushi; Hachisu, Takuma; Osaka, Tetsuya
In the advanced information society of today, information storage technology, which helps to store a mass of electronic data and offers high-speed random access to the data, is indispensable. Against this background, hard disk drives (HDD), which are magnetic recording devices, have gained in importance because of their advantages in capacity, speed, reliability, and production cost. These days, the uses of HDD extend not only to personal computers and network servers but also to consumer electronics products such as personal video recorders, portable music players, car navigation systems, video games, video cameras, and personal digital assistances.
Code of Federal Regulations, 2010 CFR
2010-10-01
... person or persons. Such a device may be used for auricular training in an education institution, for... electronic computations, operations, transformations, recording, filing, sorting, storage, retrieval, or...
Electronic Mail for Personal Computers: Development Issues.
ERIC Educational Resources Information Center
Tomer, Christinger
1994-01-01
Examines competing, commercially developed electronic mail programs and how these technologies will affect the functionality and quality of electronic mail. How new standards for client-server mail systems are likely to enhance messaging capabilities and the use of electronic mail for information retrieval are considered. (Contains eight…
Electronic Health Records Place 1st at Indy 500
... Navigation Bar Home Current Issue Past Issues EHR Electronic Health Records Place 1st at Indy 500 Past ... last May's Indy 500 had thousands of personal Electronic Health Records on hand for those attending—and ...
Hertz, Marci Feldman; Jones, Sherry Everett; Barrios, Lisa; David-Ferdon, Corinne; Holt, Melissa
2016-01-01
BACKGROUND Childhood exposure to adverse experiences has been associated with adult asthma, smoking, sexually transmitted disease, obesity, substance use, depression, and sleep disturbances. Conceptualizing bullying as an adverse childhood experience, 2011 Youth Risk Behavior Survey (YRBS) data were used to examine the relationship between in-person and electronic bullying victimization among US high school students and health risk behaviors and conditions related to violence, substance use, sexual risk, overweight and physical activity, sleep, and asthma. METHODS Data were from the 2011 national YRBS among students who answered questions about in-person and electronic bullying (N=13,846). The YRBS is a biennial, nationally representative survey of students in grades 9–12 (overall response rate=71%). Logistic regression analyses, stratified by sex and controlling for race/ethnicity and grade, examined the association between bullying victimization and health risk behaviors or conditions. RESULTS Rates of victimization varied; 9.4% of students reported being bullied in-person and electronically, 10.8% only bullied in-person, 6.8% only electronically bullied, and 73.0% uninvolved. Bullying was associated with nearly all health risk behaviors and conditions studied. CONCLUSION Assessing the broad functioning and behaviors of victims of bullying could enable educators and health practitioners to intervene early and promote the long-term health of youth. PMID:26522172
Hertz, Marci Feldman; Everett Jones, Sherry; Barrios, Lisa; David-Ferdon, Corinne; Holt, Melissa
2015-12-01
Childhood exposure to adverse experiences has been associated with adult asthma, smoking, sexually transmitted disease, obesity, substance use, depression, and sleep disturbances. Conceptualizing bullying as an adverse childhood experience, 2011 Youth Risk Behavior Survey (YRBS) data were used to examine the relationship between in-person and electronic bullying victimization among US high school students and health risk behaviors and conditions related to violence, substance use, sexual risk, overweight and physical activity, sleep, and asthma. Data were from the 2011 national YRBS among students who answered questions about in-person and electronic bullying (N = 13,846). The YRBS is a biennial, nationally representative survey of students in grades 9-12 (overall response rate = 71%). Logistic regression analyses, stratified by sex and controlling for race/ethnicity and grade, examined the association between bullying victimization and health risk behaviors or conditions. Rates of victimization varied; 9.4% of students reported being bullied in-person and electronically, 10.8% only bullied in-person, 6.8% only electronically bullied, and 73.0% uninvolved. Bullying was associated with nearly all health risk behaviors and conditions studied. Assessing the broad functioning and behaviors of victims of bullying could enable educators and health practitioners to intervene early and promote the long-term health of youth. © 2015, American School Health Association.
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
14 CFR 121.306 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 121.306... Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate... electronic device on any U.S.-registered civil aircraft operating under this part. (b) Paragraph (a) of this...
26 CFR 1.6055-2 - Electronic furnishing of statements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 13 2014-04-01 2014-04-01 false Electronic furnishing of statements. 1.6055-2... TAX (CONTINUED) INCOME TAXES (CONTINUED) Information Returns § 1.6055-2 Electronic furnishing of statements. (a) Electronic furnishing of statements—(1) In general. A person required by section 6055 to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
Southwest electronic one-stop shopping, motor carrier test report
DOT National Transportation Integrated Search
1997-12-22
The Electronic One-Stop System (EOSS) used in this credential test was designed to replace current normal credentialling procedures with a personal computer-based electronic method that allows users to prepare, apply for, and obtain certain types of ...
Southwest electronic one-stop shopping, state agency test report
DOT National Transportation Integrated Search
1997-12-22
The Electronic One-Stop System (EOSS) used in this credential test was designed to replace current normal credentialling procedures with a personal computer-based electronic method that allows users to prepare, apply for, and obtain certain types of ...
Goren, AD; Prins, RD; Dauer, LT; Quinn, B; Al-Najjar, A; Faber, RD; Patchell, G; Branets, I; Colosi, DC
2013-01-01
Objectives: This study aims to demonstrate the effectiveness of leaded glasses in reducing the lens of eye dose and of lead thyroid collars in reducing the dose to the thyroid gland of an adult female from dental cone beam CT (CBCT). The effect of collimation on the radiation dose in head organs is also examined. Methods: Dose measurements were conducted by placing optically stimulated luminescent dosemeters in an anthropomorphic female phantom. Eye lens dose was measured by placing a dosemeter on the anterior surface of the phantom eye location. All exposures were performed on one commercially available dental CBCT machine, using selected collimation and exposure techniques. Each scan technique was performed without any lead shielding and then repeated with lead shielding in place. To calculate the percent reduction from lead shielding, the dose measured with lead shielding was divided by the dose measured without lead shielding. The percent reduction from collimation was calculated by comparing the dose measured with collimation to the dose measured without collimation. Results: The dose to the internal eye for one of the scans without leaded glasses or thyroid shield was 0.450 cGy and with glasses and thyroid shield was 0.116 cGy (a 74% reduction). The reduction to the lens of the eye was from 0.396 cGy to 0.153 cGy (a 61% reduction). Without glasses or thyroid shield, the thyroid dose was 0.158 cGy; and when both glasses and shield were used, the thyroid dose was reduced to 0.091 cGy (a 42% reduction). Conclusions: Collimation alone reduced the dose to the brain by up to 91%, with a similar reduction in other organs. Based on these data, leaded glasses, thyroid collars and collimation minimize the dose to organs outside the field of view. PMID:23412460
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF TRANSPORTATION RAILROAD COMMUNICATIONS Electronic Devices § 220.313 Instruction. (a) Program... explanation of the following: (i) When a railroad operating employee must have personal electronic devices... supplies an electronic device to its railroad operating employees, when a railroad operating employee may...
ERIC Educational Resources Information Center
Torres, Carlos A.
2011-01-01
This study investigated college students' attitudes toward and intentions to use personal health portals (PHPs) for managing their personal health information using a survey method. The study also aimed to examine the roles electronic Personal Health Information Management (PHIM) anxiety and apathy play in influencing students' attitudes toward…
ERIC Educational Resources Information Center
Rice, Michael
This report summarizes the presentations and discussions at a conference on the development of new products and services in electronic publishing and computer software for personal use. It is noted that the 26 participants came from a variety of perspectives, including the publishing and computer software industries; the fields of home…
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
21 CFR 1311.05 - Standards for technologies for electronic transmission of orders.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Standards for technologies for electronic... JUSTICE REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS General § 1311.05 Standards for technologies for electronic transmission of orders. (a) A registrant or a person with power of attorney to sign...
21 CFR 1311.05 - Standards for technologies for electronic transmission of orders.
Code of Federal Regulations, 2010 CFR
2010-04-01
... technologies for electronic transmission of orders. (a) A registrant or a person with power of attorney to sign orders for Schedule I and II controlled substances may use any technology to sign and electronically... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Standards for technologies for electronic...
... chart there, too. These charts are your medical records. They may be on paper or electronic. To ... good idea to keep your own personal health record. What kind of information would you put in ...
Code of Federal Regulations, 2013 CFR
2013-04-01
... Relations DEPARTMENT OF STATE NATIONALITY AND PASSPORTS PASSPORTS § 51.1 Definitions. The following...) Electronic passport means a passport containing an electronically readable device, an electronic chip encoded.... (c) Minor means an unmarried, unemancipated person under 18 years of age. (d) Passport means a travel...
Code of Federal Regulations, 2014 CFR
2014-04-01
... Relations DEPARTMENT OF STATE NATIONALITY AND PASSPORTS PASSPORTS § 51.1 Definitions. The following...) Electronic passport means a passport containing an electronically readable device, an electronic chip encoded.... (c) Minor means an unmarried, unemancipated person under 18 years of age. (d) Passport means a travel...
Code of Federal Regulations, 2012 CFR
2012-04-01
... Relations DEPARTMENT OF STATE NATIONALITY AND PASSPORTS PASSPORTS § 51.1 Definitions. The following...) Electronic passport means a passport containing an electronically readable device, an electronic chip encoded.... (c) Minor means an unmarried, unemancipated person under 18 years of age. (d) Passport means a travel...
Code of Federal Regulations, 2011 CFR
2011-04-01
... Relations DEPARTMENT OF STATE NATIONALITY AND PASSPORTS PASSPORTS § 51.1 Definitions. The following...) Electronic passport means a passport containing an electronically readable device, an electronic chip encoded.... (c) Minor means an unmarried, unemancipated person under 18 years of age. (d) Passport means a travel...
An Overview of Some Electronic Identification Use Cases in Europe
NASA Astrophysics Data System (ADS)
Mattatia, Fabrice
As online services become more and more widely used, and as the exchanges of personal data become more and more widespread, electronic identification appears to be a key function for the security of the process and for the protection of privacy. It is the sole means of ensuring only authorized people have access to the data. In France and throughout Europe, e-government services, as well as private services, already use different means of electronic identification. Among the different technical solutions stand the electronic identity card: around 20 million eID cards have already been issued in Europe. The question of their interoperability is now open, in order that all European citizens may access the e-services of any Member State. With the development of electronic administration comes the need for the citizen to be able to prove his or her identity. This is essential if the citizen wants access to her personal data or administrative files, or if he wants to claim a right attached to his very identity. On the other hand, administrations have the obligation to ensure the personal data they store are not displayed to people who are not entitled to see them. They also have the need to detect fraudsters. Electronic identification, which is the ability to prove someone's identity on the Internet, thus becomes a central matter.
Joshi, Veena; Dutt, Sanjay; Yadav, Manjulata; Mishra, Rosaline; Ramola, R C
2016-10-01
It is well known that inhalation of radon, thoron and their progeny contributes more than 50 % of natural background radiation dose to human being. The time-integrated passive measurements of radon, thoron and their progeny concentrations were carried out in the dwellings of Pauri Garhwal, Uttarakhand, India. The measurements of radon and thoron concentrations were performed by LR-115 detector-based single-entry pin-hole dosemeter, while for the measurement of progeny concentrations, LR-115 deposition-based direct radon and thoron progeny sensors technique was used. The experimental techniques and results obtained are discussed in detail. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Simulated workplace neutron fields
NASA Astrophysics Data System (ADS)
Lacoste, V.; Taylor, G.; Röttger, S.
2011-12-01
The use of simulated workplace neutron fields, which aim at replicating radiation fields at practical workplaces, is an alternative solution for the calibration of neutron dosemeters. They offer more appropriate calibration coefficients when the mean fluence-to-dose equivalent conversion coefficients of the simulated and practical fields are comparable. Intensive Monte Carlo modelling work has become quite indispensable for the design and/or the characterization of the produced mixed neutron/photon fields, and the use of Bonner sphere systems and proton recoil spectrometers is also mandatory for a reliable experimental determination of the neutron fluence energy distribution over the whole energy range. The establishment of a calibration capability with a simulated workplace neutron field is not an easy task; to date only few facilities are available as standard calibration fields.
Code of Federal Regulations, 2014 CFR
2014-07-01
... date of birth, Social Security Number. Personal notes. Notations created in paper or electronic form..., whatever the storage media (paper, electronic, etc.) about an individual or his or her education, financial...
Code of Federal Regulations, 2012 CFR
2012-07-01
... date of birth, Social Security Number. Personal notes. Notations created in paper or electronic form..., whatever the storage media (paper, electronic, etc.) about an individual or his or her education, financial...
Code of Federal Regulations, 2010 CFR
2010-07-01
... date of birth, Social Security Number. Personal notes. Notations created in paper or electronic form..., whatever the storage media (paper, electronic, etc.) about an individual or his or her education, financial...
Code of Federal Regulations, 2013 CFR
2013-07-01
... date of birth, Social Security Number. Personal notes. Notations created in paper or electronic form..., whatever the storage media (paper, electronic, etc.) about an individual or his or her education, financial...
Code of Federal Regulations, 2011 CFR
2011-07-01
... date of birth, Social Security Number. Personal notes. Notations created in paper or electronic form..., whatever the storage media (paper, electronic, etc.) about an individual or his or her education, financial...
Future opportunities for advancing glucose test device electronics.
Young, Brian R; Young, Teresa L; Joyce, Margaret K; Kennedy, Spencer I; Atashbar, Massood Z
2011-09-01
Advancements in the field of printed electronics can be applied to the field of diabetes testing. A brief history and some new developments in printed electronics components applicable to personal test devices, including circuitry, batteries, transmission devices, displays, and sensors, are presented. Low-cost, thin, and lightweight materials containing printed circuits with energy storage or harvest capability and reactive/display centers, made using new printing/imaging technologies, are ideal for incorporation into personal-use medical devices such as glucose test meters. Semicontinuous rotogravure printing, which utilizes flexible substrates and polymeric, metallic, and/or nano "ink" composite materials to effect rapidly produced, lower-cost printed electronics, is showing promise. Continuing research advancing substrate, "ink," and continuous processing development presents the opportunity for research collaboration with medical device designers. © 2011 Diabetes Technology Society.
LabVIEW Serial Driver Software for an Electronic Load
NASA Technical Reports Server (NTRS)
Scullin, Vincent; Garcia, Christopher
2003-01-01
A LabVIEW-language computer program enables monitoring and control of a Transistor Devices, Inc., Dynaload WCL232 (or equivalent) electronic load via an RS-232 serial communication link between the electronic load and a remote personal computer. (The electronic load can operate at constant voltage, current, power consumption, or resistance.) The program generates a graphical user interface (GUI) at the computer that looks and acts like the front panel of the electronic load. Once the electronic load has been placed in remote-control mode, this program first queries the electronic load for the present values of all its operational and limit settings, and then drops into a cycle in which it reports the instantaneous voltage, current, and power values in displays that resemble those on the electronic load while monitoring the GUI images of pushbuttons for control actions by the user. By means of the pushbutton images and associated prompts, the user can perform such operations as changing limit values, the operating mode, or the set point. The benefit of this software is that it relieves the user of the need to learn one method for operating the electronic load locally and another method for operating it remotely via a personal computer.
21 CFR 1003.2 - Defect in an electronic product.
Code of Federal Regulations, 2014 CFR
2014-04-01
... genetic injury, to any person, or (2) It fails to conform to its design specifications relating to... injury, including genetic injury to any person; or (3) Fails to accomplish the intended purpose. ...
21 CFR 1003.2 - Defect in an electronic product.
Code of Federal Regulations, 2013 CFR
2013-04-01
... genetic injury, to any person, or (2) It fails to conform to its design specifications relating to... injury, including genetic injury to any person; or (3) Fails to accomplish the intended purpose. ...
28 CFR 45.4 - Personal use of Government property.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Government office and library equipment and facilities are hereby authorized: (1) Personal uses that involve... Departmental policies governing the use of electronic mail; and 41 CFR (FPMR) 101-35.201, governing the...
Macías, M T; Navarro, T; Lavara, A; Robredo, L M; Sierra, I; Lopez, M A
2003-01-01
The radioisotope techniques used in molecular and cellular biology involve external and internal irradiation risk. The personal dosemeter may be a reasonable indicator for external irradiation. However, it is necessary to control the possible internal contamination associated with the development of these techniques. The aim of this project is to analyse the most usual techniques and to establish programmes of internal monitoring for specific radionuclides (32P, 35S, 14C, 3H, 125I and 131I). To elaborate these programmes it was necessary to analyse the radioisotope techniques. Two models have been applied (NRPB and IAEA) to the more significant techniques, according to the physical and chemical nature of the radionuclides, their potential importance in occupational exposure and the possible injury to the genetic material of the cell. The results allowed the identification of the techniques with possible risk of internal contamination. It was necessary to identify groups of workers that require individual monitoring. The risk groups have been established among the professionals exposed, according to different parameters: the general characteristics of receptor, the radionuclides used (the same user can work with one, two or three radionuclides at the same time) and the results of the models applied. Also a control group was established. The study of possible intakes in these groups has been made by urinalysis and whole-body counter. The theoretical results are coherent with the experimental results. They have allowed guidance to individual monitoring to be proposed. Basically, the document shows: (1) the analysis of the radiosotopic techniques, taking into account the special containment equipment; (2) the establishment of the need of individual monitoring; and (3) the required frequency of measurements in a routine programme.
Code of Federal Regulations, 2014 CFR
2014-01-01
... violence means the occurrence of one or more of the following acts by a current or former family member... person. Electronic media includes any means for transmitting messages electronically between a covered...
Code of Federal Regulations, 2012 CFR
2012-01-01
... violence means the occurrence of one or more of the following acts by a current or former family member... person. Electronic media includes any means for transmitting messages electronically between a covered...
Code of Federal Regulations, 2013 CFR
2013-01-01
... violence means the occurrence of one or more of the following acts by a current or former family member... person. Electronic media includes any means for transmitting messages electronically between a covered...
ERIC Educational Resources Information Center
McClellan, Molly Ann
2011-01-01
Many models currently exist for evaluating acceptance and continued use of technology. However, none of these models are healthcare specific, nor do they involve aspects of users' personality. Although the five-factor model (FFM) of personality has been effectively used in psychology and human resources and management research to predict…
Using Personal Computers To Acquire Special Education Information. Revised. ERIC Digest #429.
ERIC Educational Resources Information Center
ERIC Clearinghouse on Handicapped and Gifted Children, Reston, VA.
This digest offers basic information about resources, available to users of personal computers, in the area of professional development in special education. Two types of resources are described: those that can be purchased on computer diskettes and those made available by linking personal computers through electronic telephone networks. Resources…
12 CFR 205.10 - Preauthorized transfers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 2 2011-01-01 2011-01-01 false Preauthorized transfers. 205.10 Section 205.10 Banks and Banking FEDERAL RESERVE SYSTEM BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM ELECTRONIC...'s account—(1) Notice by financial institution. When a person initiates preauthorized electronic fund...
A Plan for Air Force Use of the World Wide Web
1995-01-01
Communications Tool Eschewing personal computers in this day and age is like saying "~no * * thanky ’ to refrigeration. Bill Machrone, PC Magazine 4I... in 1989.’ Omni Magazine is now available only on CD-ROM or online. Some, like New York Magazine , have begun an electronic bulletin board to - reach...One person with 10 years experience running an electronic bulletin board system for magazines explains, "It’s a pain in the arse to keep them running
Electronic Health Record in Italy and Personal Data Protection.
Bologna, Silvio; Bellavista, Alessandro; Corso, Pietro Paolo; Zangara, Gianluca
2016-06-01
The present article deals with the Italian Electronic Health Record (hereinafter EHR), recently introduced by Act 221/2012, with a specific focus on personal data protection. Privacy issues--e.g., informed consent, data processing, patients' rights and minors' will--are discussed within the framework of recent e-Health legislation, national Data Protection Code, the related Data Protection Authority pronouncements and EU law. The paper is aimed at discussing the problems arising from a complex, fragmentary and sometimes uncertain legal framework on e-Health.
Robinson, June K; Gaber, Rikki; Hultgren, Brittney; Eilers, Steven; Blatt, Hanz; Stapleton, Jerod; Mallett, Kimberly; Turrisi, Rob; Duffecy, Jenna; Begale, Mark; Martini, Mary; Bilimoria, Karl; Wayne, Jeffrey
2014-01-13
Early detection of melanoma improves survival. Since many melanoma patients and their spouses seek the care of a physician after discovering their melanoma, an ongoing study will determine the efficacy of teaching at-risk melanoma patients and their skin check partner how to conduct skin self-examinations (SSEs). Internet-based health behavior interventions have proven efficacious in creating behavior change in patients to better prevent, detect, or cope with their health issues. The efficacy of electronic interactive SSE educational intervention provided on a tablet device has not previously been determined. The electronic interactive educational intervention was created to develop a scalable, effective intervention to enhance performance and accuracy of SSE among those at-risk to develop melanoma. The intervention in the office was conducted using one of the following three methods: (1) in-person through a facilitator, (2) with a paper workbook, or (3) with a tablet device used in the clinical office. Differences related to method of delivery were elucidated by having the melanoma patient and their skin check partner provide a self-report of their confidence in performing SSE and take a knowledge-based test immediately after receiving the intervention. The three interventions used 9 of the 26 behavioral change techniques defined by Abraham and Michie to promote planning of monthly SSE, encourage performing SSE, and reinforce self-efficacy by praising correct responses to knowledge-based decision making and offering helpful suggestions to improve performance. In creating the electronic interactive SSE educational intervention, the educational content was taken directly from both the scripted in-person presentation delivered with Microsoft PowerPoint by a trained facilitator and the paper workbook training arms of the study. Enrollment totaled 500 pairs (melanoma patient and their SSE partner) with randomization of 165 pairs to the in-person, 165 pairs to the workbook, and 70 pairs to electronic interactive SSE educational intervention. The demographic survey data showed no significant mean differences between groups in age, education, or income. The tablet usability survey given to the first 30 tablet pairs found that, overall, participants found the electronic interactive intervention easy to use and that the video of the doctor-patient-partner dialogue accompanying the dermatologist's examination was particularly helpful in understanding what they were asked to do for the study. The interactive group proved to be just as good as the workbook group in self-confidence of scoring moles, and just as good as both the workbook and the in-person intervention groups in self-confidence of monitoring their moles. While the in-person intervention performed significantly better on a skill-based quiz, the electronic interactive group performed significantly better than the workbook group. The electronic interactive and in-person interventions were more efficient (30 minutes), while the workbook took longer (45 minutes). This study suggests that an electronic interactive intervention can deliver skills training comparable to other training methods, and the experience can be accommodated during the customary outpatient office visit with the physician. Further testing of the electronic interactive intervention's role in the anxiety of the pair and pair-discovered melanomas upon self-screening will elucidate the impact of these tools on outcomes in at-risk patient populations. ClinicalTrials.gov NCT01013844; http://clinicaltrials.gov/show/NCT01013844 (Archived by WebCite at http://www.webcitation.org/6LvGGSTKK).
Electronic Networking as an Avenue of Enhanced Professional Interchange.
ERIC Educational Resources Information Center
Ratcliff, James L.
Electronic networking is communication between two or more people that involves one or more telecommunications media. There is electronic networking software available for most computers, including IBM, Apple, and Radio Shack personal computers. Depending upon the sophistication of the hardware and software used, individuals and groups can…
75 FR 5066 - Commission Information Collection Activities (FERC Form 60,1
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-01
... corresponding dockets and collection numbers.) Comments may be filed either electronically or in paper format. Those persons filing electronically do not need to make a paper filing. Documents filed electronically... acknowledgement to the sender's e- mail address upon receipt of comments. For paper filings, the comments should...
21 CFR 11.30 - Controls for open systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Controls for open systems. 11.30 Section 11.30... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.30 Controls for open systems. Persons who use open systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls...
21 CFR 11.30 - Controls for open systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Controls for open systems. 11.30 Section 11.30... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.30 Controls for open systems. Persons who use open systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls...
21 CFR 11.30 - Controls for open systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Controls for open systems. 11.30 Section 11.30... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.30 Controls for open systems. Persons who use open systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls...
21 CFR 11.30 - Controls for open systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Controls for open systems. 11.30 Section 11.30... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.30 Controls for open systems. Persons who use open systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls...
21 CFR 11.30 - Controls for open systems.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Controls for open systems. 11.30 Section 11.30... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.30 Controls for open systems. Persons who use open systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls...
5 CFR 1201.4 - General definitions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... commercial or personal delivery, or by electronic filing (e-filing) in accordance with § 1201.14. (j) Date of... the document was delivered to the commercial delivery service. The date of filing by e-filing is the date of electronic submission. (m) Electronic filing (e-filing). Filing and receiving documents in...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-31
... accessed on the Commission's Electronic Document Information System (EDIS) at EDIS,\\1\\ and will be...-2000. \\1\\ Electronic Document Information System (EDIS): http://edis.usitc.gov . General information... the Commission's Electronic Document Information System (EDIS) at EDIS.\\3\\ Hearing-impaired persons...
Exposure assessment of workers in printed electronics workplace.
Lee, Ji Hyun; Sohn, Eun Kyung; Ahn, Jin Soo; Ahn, Kangho; Kim, Keun Soo; Lee, Jong Hwan; Lee, Taik Min; Yu, Il Je
2013-07-01
Printed electronics uses converging technologies, such as printing, fine mechanics, nanotechnology, electronics and other new technologies. Consequently, printed electronics raises additional health and safety concerns to those experienced in the traditional printing industry. This study investigated two printed electronics workplaces based on a walk-through survey and personal and area sampling. All the printed electronics operations were conducted in a cleanroom. No indication of exposure to excess silver nanoparticles or carbon nanotubes (CNTs) was found. While the organic solvents were lower than current occupational exposure limits, there was a lack of engineering controls, such as local exhaust ventilation, correct enclosure and duct connections. There was also an insufficient quantity of personal protective equipment, and some organic solvents not described in the safety data sheets (SDSs) were detected in the air samples. Plus, the cleaning work, a major emissions operation, was not conducted within a hood, and the cleaning waste was not properly disposed of. Therefore, the present exposure assessment results from two printed electronics workplaces suggest that the printed electronics industry needs to take note of the occupational safety and health risks and hazards already established by the traditional printing industry, along with new risks and hazards originating from converging technologies such as nanotechnology.
Otsuka, Shelley H.; Tayal, Neeraj H.; Porter, Kyle; Embi, Peter J.; Beatty, Stuart J.
2014-01-01
BACKGROUND Preventative health services, including herpes zoster vaccination rates, remain low despite known benefits. A new care model to improve preventative health services is warranted. The objective of this study is to investigate whether the functions of an electronic medical record, in combination with a pharmacist as part of the care team, can improve the herpes zoster vaccination rate. METHODS This study was a 6-month, randomized controlled trial at a General Internal Medicine clinic at The Ohio State University. The 2589 patients aged 60 years and older without documented herpes zoster vaccination in the electronic medical record were stratified on the basis of activated personal health record status, an online tool used to share health information between patient and provider. Of the 674 personal health record users, 250 were randomized to receive information regarding the herpes zoster vaccination via an electronic message and 424 were randomized to standard of care. Likewise, of the 1915 nonpersonal health record users, 250 were randomized to receive the same information via the US Postal Service and 1665 were randomized to standard of care. After pharmacist chart review, eligible patients were mailed a herpes zoster vaccine prescription. Herpes zoster vaccination rates were compared by chi-square tests. RESULTS Intervention recipients had significantly higher vaccination rates than controls in both personal health record (relative risk, 2.7; P = .0007) and nonpersonal health record (relative risk, 2.9; P = .0001) patient populations. CONCLUSIONS Communication outside of face-to-face office visits, by both personal health record electronic message and information by mail, can improve preventative health intervention rates compared with standard care. PMID:23830534
PA partnership publishes IT recommendations.
2007-07-01
Long-term goal is a statewide regional health information system. Partners assert that electronic health information exchange will promote safety and efficiency. Eventually, all citizens in the state will have complete personal health records available electronically.
U.S. State and Federal Laws Targeting Distracted Driving
Catherine Chase, J.D.
2014-01-01
Distracted driving has burgeoned with the proliferation of cell phones, global positioning systems and other in-vehicle and personal electronic devices. Annually more than 3,300 people are killed and an additional 400,000 are injured in the United States in distracted driving crashes. The United States (U.S.) federal and state governments have responded to this public health problem with policies and laws; however, a more comprehensive and more effective approach is still needed. Some restrictions on the use of electronic devices while driving by federal employees and some voluntary guidelines and recommendations have been issued. Public opinion polls show support for addressing the issue of distracted driving with state laws. The majority of states have laws banning text messaging while driving and prohibiting the use of an electronic device by teenage or novice drivers. Some states prohibit all drivers from using a hand-held cellphone. Currently no state has a total ban on the use of personal electronic devices while driving. Successful past traffic safety campaigns changing driver behavior have demonstrated the necessity to adopt a “three Es” approach of Enactment of a law, Education of the public about the law, and rigorous Enforcement of the law. Experience reveals that this approach, along with future federal regulation of in-vehicle electronic devices and the employment of technology to limit the use of electronic devices while driving, is needed to alter personal behavior in order to reduce distractions and keep drivers focused on the driving task. PMID:24776229
U.s. State and federal laws targeting distracted driving.
Catherine Chase, J D
2014-01-01
Distracted driving has burgeoned with the proliferation of cell phones, global positioning systems and other in-vehicle and personal electronic devices. Annually more than 3,300 people are killed and an additional 400,000 are injured in the United States in distracted driving crashes. The United States (U.S.) federal and state governments have responded to this public health problem with policies and laws; however, a more comprehensive and more effective approach is still needed. Some restrictions on the use of electronic devices while driving by federal employees and some voluntary guidelines and recommendations have been issued. Public opinion polls show support for addressing the issue of distracted driving with state laws. The majority of states have laws banning text messaging while driving and prohibiting the use of an electronic device by teenage or novice drivers. Some states prohibit all drivers from using a hand-held cellphone. Currently no state has a total ban on the use of personal electronic devices while driving. Successful past traffic safety campaigns changing driver behavior have demonstrated the necessity to adopt a "three Es" approach of Enactment of a law, Education of the public about the law, and rigorous Enforcement of the law. Experience reveals that this approach, along with future federal regulation of in-vehicle electronic devices and the employment of technology to limit the use of electronic devices while driving, is needed to alter personal behavior in order to reduce distractions and keep drivers focused on the driving task.
32 CFR 806b.29 - Sending personal information over electronic mail.
Code of Federal Regulations, 2010 CFR
2010-07-01
... methods may include encryption or password protecting the information in a separate Word document. When....mil/whs/directives/corres/pdf/54007r_0998/p54007r.pdf. (c) Do not disclose personal information to...
78 FR 52524 - Sunoco Pipeline LP; Notice of Petition for Declaratory Order
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-23
... link to log on and submit the intervention or protests. Persons unable to file electronically should... described in their petition. Any person desiring to intervene or to protest in this proceedings must file in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
78 FR 62349 - Sunoco Pipeline L.P.; Notice of Petition for Declaratory Order
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-18
... to log on and submit the intervention or protests. Persons unable to file electronically should... petition. Any person desiring to intervene or to protest in this proceeding must file in accordance with..., persons with Internet access who will eFile a document and/or be listed as a contact for an intervenor...
Multimethod Investigation of Interpersonal Functioning in Borderline Personality Disorder
Stepp, Stephanie D.; Hallquist, Michael N.; Morse, Jennifer Q.; Pilkonis, Paul A.
2011-01-01
Even though interpersonal functioning is of great clinical importance for patients with borderline personality disorder (BPD), the comparative validity of different assessment methods for interpersonal dysfunction has not yet been tested. This study examined multiple methods of assessing interpersonal functioning, including self- and other-reports, clinical ratings, electronic diaries, and social cognitions in three groups of psychiatric patients (N=138): patients with (1) BPD, (2) another personality disorder, and (3) Axis I psychopathology only. Using dominance analysis, we examined the predictive validity of each method in detecting changes in symptom distress and social functioning six months later. Across multiple methods, the BPD group often reported higher interpersonal dysfunction scores compared to other groups. Predictive validity results demonstrated that self-report and electronic diary ratings were the most important predictors of distress and social functioning. Our findings suggest that self-report scores and electronic diary ratings have high clinical utility, as these methods appear most sensitive to change. PMID:21808661
Studer, Joseph; Baggio, Stéphanie; Mohler-Kuo, Meichun; Simon, Olivier; Daeppen, Jean-Bernard; Gmel, Gerhard
2016-06-01
The study aimed to identify different patterns of gambling activities (PGAs) and to investigate how PGAs differed in gambling problems, substance use outcomes, personality traits and coping strategies. A representative sample of 4989 young Swiss males completed a questionnaire assessing seven distinct gambling activities, gambling problems, substance use outcomes, personality traits and coping strategies. PGAs were identified using latent class analysis (LCA). Differences between PGAs in gambling and substance use outcomes, personality traits and coping strategies were tested. LCA identified six different PGAs. With regard to gambling and substance use outcomes, the three most problematic PGAs were extensive gamblers, followed by private gamblers, and electronic lottery and casino gamblers, respectively. By contrast, the three least detrimental PGAs were rare or non-gamblers, lottery only gamblers and casino gamblers. With regard to personality traits, compared with rare or non-gamblers, private and casino gamblers reported higher levels of sensation seeking. Electronic lottery and casino gamblers, private gamblers and extensive gamblers had higher levels of aggression-hostility. Extensive and casino gamblers reported higher levels of sociability, whereas casino gamblers reported lower levels of anxiety-neuroticism. Extensive gamblers used more maladaptive and less adaptive coping strategies than other groups. Results suggest that gambling is not a homogeneous activity since different types of gamblers exist according to the PGA they are engaged in. Extensive gamblers, electronic and casino gamblers and private gamblers may have the most problematic PGAs. Personality traits and coping skills may predispose individuals to PGAs associated with more or less negative outcomes.
Sedghi, Shahram; Abdolahi, Nida; Azimi, Ali; Tahamtan, Iman; Abdollahi, Leila
2015-01-01
Background: Personal Information Management (PIM) refers to the tools and activities to save and retrieve personal information for future uses. This study examined the PIM activities of faculty members of Iran University of Medical Sciences (IUMS) regarding their preferred PIM tools and four aspects of acquiring, organizing, storing and retrieving personal information. Methods: The qualitative design was based on phenomenology approach and we carried out 37 interviews with clinical and basic sciences faculty members of IUMS in 2014. The participants were selected using a random sampling method. All interviews were recorded by a digital voice recorder, and then transcribed, codified and finally analyzed using NVivo 8 software. Results: The use of PIM electronic tools (e-tools) was below expectation among the studied sample and just 37% had reasonable knowledge of PIM e-tools such as, external hard drivers, flash memories etc. However, all participants used both paper and electronic devices to store and access information. Internal mass memories (in Laptops) and flash memories were the most used e-tools to save information. Most participants used "subject" (41.00%) and "file name" (33.7 %) to save, organize and retrieve their stored information. Most users preferred paper-based rather than electronic tools to keep their personal information. Conclusion: Faculty members had little knowledge about PIM techniques and tools. Those who organized personal information could easier retrieve the stored information for future uses. Enhancing familiarity with PIM tools and training courses of PIM tools and techniques are suggested. PMID:26793648
78 FR 41397 - Moss Bluff Hub, LLC; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
... modifications to Section 22 (Electronic Communications), as more fully described in the filing. Any person... encourages electronic submission of protests and interventions in lieu of paper using the ``eFiling'' link at...
ERIC Educational Resources Information Center
Sanga, Sushma
2016-01-01
Identity-theft means stealing someone's personal information and using it without his or her permission. Each year, millions of Americans are becoming the victims of identity-theft, and this is one of the seriously growing and widespread issues in the U.S. This study examines the effect of electronic devices self-efficacy, electronic devices…
An Overview of Electronic Passport Security Features
NASA Astrophysics Data System (ADS)
Říha, Zdeněk
Electronic passports include contactless chip which stores personal data of the passport holder, information about the passport and the issuing institution. In its simplest form an electronic passport contains just a collection of read-only files, more advanced variants can include sophisticated cryptographic mechanisms protecting security of the document and / or privacy of the passport holder. This paper describes security features of electronic passports and discusses their efficiency.
Enhancing privacy and data protection in electronic medical environments.
Gritzalis, Stefanos
2004-12-01
Raising awareness and providing guidance to on-line data protection is by all means a crucial issue worldwide. Equally important is the issue of applying privacy-related legislation in a coherent and coordinated way. Both these topics become even more critical when referring to medical environments and thus to the protection of patients' privacy and medical data. Electronic medical transactions require the transmission of personal and medical information over insecure communication channels like the Internet. It is therefore a rather straightforward task to construct "patient profiles " that capture the electronic medical behavior of a patient, or even reveal sensitive information in regard with her/his medical history. Clearly, the consequence from maintaining such profiles is the violation of the patient's privacy. This paper studies medical environments that can support electronic medical transactions or/and the provision of medical information through the Web. Specifically it focuses on the countermeasures that the various actor categories can employ for protecting the privacy of personal and medical data transmitted during electronic medical transactions.
Han, Wuxiao; He, Haoxuan; Zhang, Linlin; Dong, Chuanyi; Zeng, Hui; Dai, Yitong; Xing, Lili; Zhang, Yan; Xue, Xinyu
2017-09-06
The emerging multifunctional flexible electronic-skin for establishing body-electric interaction can enable real-time monitoring of personal health status as a new personalized medicine technique. A key difficulty in the device design is the flexible power supply. Here a self-powered wearable noninvasive electronic-skin for perspiration analysis has been realized on the basis of a piezo-biosensing unit matrix of enzyme/ZnO nanoarrays. The electronic-skin can detect lactate, glucose, uric acid, and urea in the perspiration, and no outside electrical power supply or battery is used in the biosensing process. The piezoelectric impulse of the piezo-biosensing units serves as the power supply and the data biosensor. The working mechanism can be ascribed to the piezoelectric-enzymatic-reaction coupling effect of enzyme/ZnO nanowires. The electronic-skin can real-time/continuously monitor the physiological state of a runner through analyzing the perspiration on his skin. This approach can promote the development of a new-type of body electric and self-powered biosensing electronic-skin.
Applications of personal computers in geophysics
NASA Astrophysics Data System (ADS)
Lee, W. H. K.; Lahr, J. C.; Habermann, R. E.
Since 1981, the use of personal computers (PCs) to increase productivity has become widespread. At present, more than 5 million personal computers are in operation for business, education, engineering, and scientific purposes. Activities within AGU reflect this trend: KOSMOS, the AGU electronic network, was introduced this year, and the AGU Committee on Personal Computers, chaired by W.H K. Lee (U.S. Geological Survey, Menlo Park, Calif.), was recently formed. In addition, in conjunction with the 1986 AGU Fall Meeting, this committee is organizing a personal computer session and hands-on demonstrations to promote applications of personal computers in geophysics.
Vincellér, S; Molnár, G; Berkane-Krachai, A; Iacconi, P
2002-01-01
Anion deficient alpha-Al2O3 is highly sensitive to ionising radiations and is widely used as a thermoluminescence and optically stimulated luminescence dosemeter in environmental monitoring. Two types of alpha alumina were studied and it was observed that both were affected by thermal quenching of luminescence. This effect, which manifests itself by the decay of the TL response when the heating rate increases, can be described by the Mott-Seitz theory. It was observed that thermostimulated exoemission response increased when the heating rate increased, whereas thermostimulated conductivity remained constant. However, none of the available theories could explain the dependence of the F- centre emission on the heating rate. A model is proposed to describe simultaneously the various thermally stimulated processes.
Liulin-type spectrometry-dosimetry instruments.
Dachev, Ts; Dimitrov, Pl; Tomov, B; Matviichuk, Yu; Spurny, F; Ploc, O; Brabcova, K; Jadrnickova, I
2011-03-01
The main purpose of Liulin-type spectrometry-dosimetry instruments (LSDIs) is cosmic radiation monitoring at the workplaces. An LSDI functionally is a low mass, low power consumption or battery-operated dosemeter. LSDIs were calibrated in a wide range of radiation fields, including radiation sources, proton and heavy-ion accelerators and CERN-EC high-energy reference field. Since 2000, LSDIs have been used in the scientific programmes of four manned space flights on the American Laboratory and ESA Columbus modules and on the Russian segment of the International Space Station, one Moon spacecraft and three spacecraft around the Earth, one rocket, two balloons and many aircraft flights. In addition to relative low price, LSDIs have proved their ability to qualify the radiation field on the ground and on the above-mentioned carriers.
PCASSO: a design for secure communication of personal health information via the internet.
Baker, D B; Masys, D R
1999-05-01
The Internet holds both promise and peril for the communications of person-identifiable health information. Because of technical features designed to promote accessibility and interoperability rather than security, Internet addressing conventions and transport protocols are vulnerable to compromise by malicious persons and programs. In addition, most commonly used personal computer (PC) operating systems currently lack the hardware-based system software protection and process isolation that are essential for ensuring the integrity of trusted applications. Security approaches designed for electronic commerce, that trade known security weaknesses for limited financial liability, are not sufficient for personal health data, where the personal damage caused by unintentional disclosure may be far more serious. To overcome these obstacles, we are developing and evaluating an Internet-based communications system called PCASSO (Patient-centered access to secure systems online) that applies state of the art security to health information. PCASSO includes role-based access control, multi-level security, strong device and user authentication, session-specific encryption and audit trails. Unlike Internet-based electronic commerce 'solutions,' PCASSO secures data end-to-end: in the server; in the data repository; across the network; and on the client. PCASSO is designed to give patients as well as providers access to personal health records via the Internet.
21 CFR 1305.04 - Persons entitled to order Schedule I and II controlled substances.
Code of Federal Regulations, 2011 CFR
2011-04-01
... to order Schedule I and II controlled substances. (a) Only persons who are registered with DEA under... are registered with DEA under section 1008 of the Act (21 U.S.C. 958) to export these substances may obtain and use DEA Form 222 (order forms) or issue electronic orders for these substances. Persons not...
21 CFR 1305.04 - Persons entitled to order Schedule I and II controlled substances.
Code of Federal Regulations, 2010 CFR
2010-04-01
... to order Schedule I and II controlled substances. (a) Only persons who are registered with DEA under... are registered with DEA under section 1008 of the Act (21 U.S.C. 958) to export these substances may obtain and use DEA Form 222 (order forms) or issue electronic orders for these substances. Persons not...
Telecommunicating in Tomorrow's World.
ERIC Educational Resources Information Center
Harkins, Judy
1983-01-01
Examples of new electronic devices used by deaf persons include electronic mail capabilities, teleprompters that can caption television live, and speech synthesis equipment. Consumers can establish and use assistive device centers to become familiar with the latest in technology. (CL)
Sun, Mingui; Burke, Lora E.; Baranowski, Thomas; Fernstrom, John D.; Zhang, Hong; Chen, Hsin-Chen; Bai, Yicheng; Li, Yuecheng; Li, Chengliu; Yue, Yaofeng; Li, Zhen; Nie, Jie; Sclabassi, Robert J.; Mao, Zhi-Hong; Jia, Wenyan
2015-01-01
Recently, wearable computers have become new members in the family of mobile electronic devices, adding new functions to those provided by smartphones and tablets. As “always-on” miniature computers in the personal space, they will play increasing roles in the field of healthcare. In this work, we present our development of eButton, a wearable computer designed as a personalized, attractive, and convenient chest pin in a circular shape. It contains a powerful microprocessor, numerous electronic sensors, and wireless communication links. We describe its design concepts, electronic hardware, data processing algorithms, and its applications to the evaluation of diet, physical activity and lifestyle in the study of obesity and other chronic diseases. PMID:25708374
Sun, Mingui; Burke, Lora E; Baranowski, Thomas; Fernstrom, John D; Zhang, Hong; Chen, Hsin-Chen; Bai, Yicheng; Li, Yuecheng; Li, Chengliu; Yue, Yaofeng; Li, Zhen; Nie, Jie; Sclabassi, Robert J; Mao, Zhi-Hong; Jia, Wenyan
2015-01-01
Recently, wearable computers have become new members in the family of mobile electronic devices, adding new functions to those provided by smart-phones and tablets. As "always-on" miniature computers in the personal space, they will play increasing roles in the field of healthcare. In this work, we present our development of eButton, a wearable computer designed as a personalized, attractive, and convenient chest pin in a circular shape. It contains a powerful microprocessor, numerous electronic sensors, and wireless communication links. We describe its design concepts, electronic hardware, data processing algorithms, and its applications to the evaluation of diet, physical activity and lifestyle in the study of obesity and other chronic diseases.
Personal Electronic Devices and Their Interference with Aircraft Systems
NASA Technical Reports Server (NTRS)
Ross, Elden; Ely, Jay J. (Technical Monitor)
2001-01-01
A compilation of data on personal electronic devices (PEDs) attributed to having created anomalies with aircraft systems. Charts and tables display 14 years of incidents reported by pilots to the Aviation Safety Reporting System (ASRS). Affected systems, incident severity, sources of anomaly detection, and the most frequently identified PEDs are some of the more significant data. Several reports contain incidents of aircraft off course when all systems indicated on course and of critical events that occurred during landings and takeoffs. Additionally, PEDs that should receive priority in testing are identified.
Environmental scanning electron microscopy of personal and household products.
Hoyberg, K
1997-03-01
The ability to forego sample preparation and to make observation directly in the environmental scanning electron microscope has benefited both household and personal product research at Unilever Research. Product efficacy on biological materials such as microcomedones was easily ascertained. Skin biopsies were examined in a moist state with no sample preparation. Effects of relative humidity on detergents were visually determined by recreating the necessary conditions in the microscope. Effects of cooling rates on the morphology of softener sheet actives that remained on polyester fabric were characterized via dynamic experimentation.
Rickmann, M; Siklós, L; Joó, F; Wolff, J R
1990-09-01
An interface for IBM XT/AT-compatible computers is described which has been designed to read the actual specimen stage position of electron microscopes. The complete system consists of (i) optical incremental encoders attached to the x- and y-stage drivers of the microscope, (ii) two keypads for operator input, (iii) an interface card fitted to the bus of the personal computer, (iv) a standard configuration IBM XT (or compatible) personal computer optionally equipped with a (v) HP Graphic Language controllable colour plotter. The small size of the encoders and their connection to the stage drivers by simple ribbed belts allows an easy adaptation of the system to most electron microscopes. Operation of the interface card itself is supported by any high-level language available for personal computers. By the modular concept of these languages, the system can be customized to various applications, and no computer expertise is needed for actual operation. The present configuration offers an inexpensive attachment, which covers a wide range of applications from a simple notebook to high-resolution (200-nm) mapping of tissue. Since section coordinates can be processed in real-time, stereological estimations can be derived directly "on microscope". This is exemplified by an application in which particle numbers were determined by the disector method.
Namoğlu, Nihan; Ulgen, Yekta
2013-01-01
Healthcare industry has become widely dependent on information technology and internet as it moves from paper to electronic records. Healthcare Information System has to provide a high quality service to patients and a productive knowledge share between healthcare staff by means of patient data. With the internet being commonly used across hospitals, healthcare industry got its own share from cyber threats like other industries in the world. The challenge is allowing knowledge transfer to hospital staff while still ensuring compliance with security mandates. Working in collaboration with a private hospital in Turkey; this study aims to reveal the essential elements of a 21st century business continuity plan for hospitals while presenting the security vulnerabilities in the current hospital information systems and personal privacy auditing standards proposed by regulations and laws. We will survey the accreditation criteria in Turkey and counterparts in US and EU. We will also interview with medical staff in the hospital to understand the needs for personal privacy and the technical staff to perceive the technical requirements in terms of network security configuration and deployment. As hospitals are adopting electronic transactions, it should be considered a must to protect these electronic health records in terms of personal privacy aspects.
Lee, Jisan; Kim, James G Boram; Jin, Meiling; Ahn, Kiwhan; Kim, Byungjun; Kim, Sukwha; Kim, Jeongeun
2017-11-01
Healthcare consumers must be able to make decisions based on accurate health information. To assist with this, we designed and developed an integrated system connected with electronic medical records in hospitals to ensure delivery of accurate health information. The system-called the Consumer-centered Open Personal Health Record platform-is composed of two services: a portal for users with any disease and a mobile application for users with cleft lip/palate. To assess the benefits of these services, we used a quasi-experimental, pretest-posttest design, assigning participants to the portal (n = 50) and application (n = 52) groups. Both groups showed significantly increased knowledge, both objective (actual knowledge of health information) and subjective (perceived knowledge of health information), after the intervention. Furthermore, while both groups showed higher information needs satisfaction after the intervention, the application group was significantly more satisfied. Knowledge changes were more affected by participant characteristics in the application group. Our results may be due to the application's provision of specific disease information and a personalized treatment plan based on the participant and other users' data. We recommend that services connected with electronic medical records target specific diseases to provide personalized health management to patients in a hospital setting.
Dr. Lindberg's Legacy : Charting A New Course | NIH MedlinePlus the Magazine
... technology, artificial intelligence, computer-aided medical diagnosis, and electronic health records. As the first President of the ... about it—when Don began, NLM had no electronic journals in its collection, few people owned personal ...
Code of Federal Regulations, 2014 CFR
2014-01-01
... person who initiates, to a protected computer, the transmission of a commercial electronic mail message... electronic mail message or other form of Internet-based communication requesting not to receive future... received; and (B) Remains capable of receiving such messages or communications for no less than 30 days...
Code of Federal Regulations, 2013 CFR
2013-01-01
... person who initiates, to a protected computer, the transmission of a commercial electronic mail message... electronic mail message or other form of Internet-based communication requesting not to receive future... received; and (B) Remains capable of receiving such messages or communications for no less than 30 days...
Code of Federal Regulations, 2012 CFR
2012-01-01
... person who initiates, to a protected computer, the transmission of a commercial electronic mail message... electronic mail message or other form of Internet-based communication requesting not to receive future... received; and (B) Remains capable of receiving such messages or communications for no less than 30 days...
Code of Federal Regulations, 2011 CFR
2011-01-01
... person who initiates, to a protected computer, the transmission of a commercial electronic mail message... electronic mail message or other form of Internet-based communication requesting not to receive future... received; and (B) Remains capable of receiving such messages or communications for no less than 30 days...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-16
... to Docket No. IC10-542-001. Comments may be filed either electronically or in paper format. Those persons filing electronically do not need to make a paper filing. Documents filed electronically via the... sender's e-mail address upon receipt of comments. For paper filings, the comments should be submitted to...
The Future of Educational Media.
ERIC Educational Resources Information Center
Wason, Walter P.
Electronic media, particularly television, influence children to develop composite, plastic personalities striving after unreal goals, but the teacher can help children identify and develop rational goals and role models without completely abandoning media. Television has influenced children, and many adults, to create personalities assembled from…
The Changing Environment of Personal Information Systems.
ERIC Educational Resources Information Center
Burton, Hilary D.
1985-01-01
Discusses technological developments causing changes in personal information systems: increase in commercial support services; proliferation of microcomputers; capability to download from secondary services into private files; and developing desire to utilize functions such as electronic mail and automated office functions. Appendices list 21…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farah, J; Trompier, F; Stolarczyk, L
2014-06-15
Purpose: Intercomparison of active dosemeters in the measurement of stray radiation at the Trento active-scanning proton therapy facility. Methods: EURADOS WG9 carried out a large intercomparison exercise to test different dosemeters while measuring secondary neutrons within a 230 MeV scanned proton therapy facility. Detectors included two Bonner Sphere Spectrometers (BSS), three tissue equivalent proportional counters (TEPCHawk) and six rem-counters (Wendi II, Berthold, RadEye, a regular and an extended-range Anderson and Braun NM2B counters). Measurements of neutron ambient dose equivalents, H*(10), were done at several positions inside (8 positions) and outside (3 positions) the treatment room while irradiating a water tankmore » phantom with a 10 × 10 × 10 cc field. Results: A generally good agreement on H*(10) values was observed for the tested detectors. At distance of 2.25 m and angles 45°, 90° and 180° with respect to the beam axis, BSS and proportional counters agreed within 30%. Higher differences (up to 60%) were observed at the closest and farthest distances, i.e. at positions where detectors sensitivity, energy, fluence and angular response are highly dependent on neutron spectra (flux and energy). The highest neutron H*(10) value, ∼60 microSv/Gy, was measured at 1.15 m along the beam axis. H*(10) decreased significantly with the distance from the isocenter dropping to 1.1 microSv/Gy at 4.25 m and 90° from beam axis, ∼2 nanoSv/Gy at the entrance of the maze, 0.2 nanoSv/Gy at the door outside the room and below detection limit in the gantry control room and at an adjacent room. These values remain considerately lower than those of passively scattered proton beams. BSS and Hawk unfolded spectra provide valuable inputs when studying the response of each detector. Conclusion: TEPCs and BSS enable accurate measurements of stray neutrons while other rem-meters also give satisfactory results but require further improvements to reduce uncertainties.« less
Stress Associated with Transportation: A Survey of Persons with Visual Impairments
ERIC Educational Resources Information Center
Crudden, Adele; Cmar, Jennifer L.; McDonnall, Michele C.
2017-01-01
Introduction: This study evaluated transportation-related stress and factors predicting stress among persons with visual impairments. Methods: Participants with visual impairments completed electronic surveys rating their stress levels experienced when completing various walking and public transportation tasks. They also indicated activities they…
Lemaire, Edward; Greene, G
2003-01-01
We produced continuing education material in physical rehabilitation using a variety of electronic media. We compared four methods of delivering the learning modules: in person with a computer projector, desktop videoconferencing, Web pages and CD-ROM. Health-care workers at eight community hospitals and two nursing homes were asked to participate in the project. A total of 394 questionnaires were received for all modalities: 73 for in-person sessions, 50 for desktop conferencing, 227 for Web pages and 44 for CD-ROM. This represents a 100% response rate from the in-person, desktop conferencing and CD-ROM groups; the response rate for the Web group is unknown, since the questionnaires were completed online. Almost all participants found the modules to be helpful in their work. The CD-ROM group gave significantly higher ratings than the Web page group, although all four learning modalities received high ratings. A combination of all four modalities would be required to provide the best possible learning opportunity.
1990-04-01
and a stepped lead flattening filter. The electron energy used for these studies was 13 MeV. Dosimetry was performed by the Health Physics Division...VolI LJSAFSAPA-TR-90-4 AD-A222 722 SURVIVAL OF CHINESE HAMSTER OVARY CELLS FOLLOWING ULTRAHIGH DOSE RATE ELECTRON AND BREMISSTRAHLUNG RADIATION...Include Security ;a!. iatcn) Survival of Chinese Hamster Ovary Cells Following Ultrahigh Dose Rate Electron and Bremsstrahlung Radiation 12 PERSONAL
NASA Astrophysics Data System (ADS)
Kim, Dae-Hyeong; Lee, Mincheol; Lee, Hyunjae
2016-05-01
Recent advances in soft electronics have attracted great attention, largely due to their potential applications in personalized, bio-integrated healthcare devices. The mechanical mismatch between conventional electronic/optoelectronic devices and soft human tissues/organs have presented many challenges, such as the low signalto- noise ratio of biosensors because of the incomplete integration of rigid devices with the body, inflammation and excessive immune responses of implanted stiff devices originated from friction and their foreign nature to biotic systems, and the considerable discomfort and consequent stress experienced by users when wearing/implanting these devices. Ultra-flexible and stretchable electronic devices are being highlighted due to their low system modulus and the intrinsic system-level softness that are important to solve these issues. Here, we describe our unique strategies for the nanomaterial synthesis and fabrication, their seamless assembly and integration, and the design and development of corresponding wearable healthcare devices and minimally invasive surgical tools. These bioelectronic systems fully utilize recent breakthroughs in unconventional soft electronics based on nanomaterials to address unsolved issues in clinical medicine and to provide new opportunities in the personalized healthcare.
Brandner, Antje; Schreiweis, Björn; Aguduri, Lakshmi S; Bronsch, Tobias; Kunz, Aline; Pensold, Peter; Stein, Katharina E; Weiss, Nicolas; Yüksekogul, Nilay; Bergh, Björn; Heinze, Oliver
2016-01-01
Over the last years we stepwise implemented our vision of a personal cross-enterprise electronic health record (PEHR) in the Rhine-Neckar-Region in Germany. The patient portal is one part of the PEHR architecture with IHE connectivity. The patient is enabled to access and manage his medical record by use of the patient portal. Moreover, he can give his consent regarding which healthcare providers are allowed to send data into or read data from his medical record. Forthcoming studies will give evidence for improvements and further requirements to develop.
Mediation and the Electronic World.
ERIC Educational Resources Information Center
Swan, John; And Others
1992-01-01
Three articles discuss the issue of the mediator's role in the library of the electronic age. Topics addressed include computer-assisted instruction; online catalogs; computer networks; professional identity; reference service and bibliographic instruction; CD-ROMs; online systems; personal home microcomputers; Internet and list servers;…
45 CFR 164.312 - Technical safeguards.
Code of Federal Regulations, 2012 CFR
2012-10-01
... REQUIREMENTS SECURITY AND PRIVACY Security Standards for the Protection of Electronic Protected Health... that maintain electronic protected health information to allow access only to those persons or software... specifications: (i) Unique user identification (Required). Assign a unique name and/or number for identifying and...
Today's Personal Computers: Products for Every Need--Part II.
ERIC Educational Resources Information Center
Personal Computing, 1981
1981-01-01
Looks at microcomputers manufactured by Altos Computer Systems, Cromemco, Exidy, Intelligent Systems, Intertec Data Systems, Mattel, Nippon Electronics, Northstar, Personal Micro Computers, and Sinclair. (Part I of this article, examining other computers, appeared in the May 1981 issue.) Journal availability: Hayden Publishing Company, 50 Essex…
5 CFR 850.303 - Return of personal documents.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., OPM may provide the individual with a copy of the document that is derived from electronic records. ... 5 Administrative Personnel 2 2012-01-01 2012-01-01 false Return of personal documents. 850.303 Section 850.303 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE...
5 CFR 850.303 - Return of personal documents.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., OPM may provide the individual with a copy of the document that is derived from electronic records. ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Return of personal documents. 850.303 Section 850.303 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE...
5 CFR 850.303 - Return of personal documents.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., OPM may provide the individual with a copy of the document that is derived from electronic records. ... 5 Administrative Personnel 2 2013-01-01 2013-01-01 false Return of personal documents. 850.303 Section 850.303 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE...
5 CFR 850.303 - Return of personal documents.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., OPM may provide the individual with a copy of the document that is derived from electronic records. ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Return of personal documents. 850.303 Section 850.303 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE...
ERIC Educational Resources Information Center
Bollet, Robert M.; Fallon, Santiago
2002-01-01
Discussion of the concepts of learning and training focuses on how to incorporate the whole brain in the learning process when personalizing electronic learning. Suggests that trainers will need to learn teaching strategies that embrace the right brain's need for time and space to examine, contemplate, integrate, and utilize information.…
Kelly, Erin L; Braslow, Joel T; Brekke, John S
2018-05-03
Individuals with serious mental illnesses have high rates of comorbid physical health issues and have numerous barriers to addressing their health and health care needs. The present pilot study tested the feasibility of a modified form of the "Bridge" peer-health navigator intervention delivered in a usual care setting by agency personnel. The modifications concerned the use of an electronic personal health record with individuals experiencing with housing instability. Twenty participants were randomized to receive the intervention immediately or after 6 months. Health navigator contacts and use of personal health records were associated with improvements in health care and self-management. This pilot study demonstrated promising evidence for the feasibility of adding personal health record use to a peer-led intervention.
NASA Astrophysics Data System (ADS)
Korir, Geoffrey; Wambani, Jeska; Korir, Ian
2011-04-01
This study details the distribution and trends of doses due to occupational radiation exposure among radiation workers from participating medical institutions in Kenya, where monthly dose measurements were collected for a period of one year ranging from January to December in 2007. A total of 367 medical radiation workers were monitored using thermoluminescent dosemeters. They included radiologists (27%), oncologists (2%), dentists (4%), Physicists (5%), technologists (45%), nurses (4%), film processor technicians (3%), auxiliary staff (4%), and radiology office staff (5%). The average annual effective dose of all categories of staff was found to range from 1.19 to 2.52 mSv. This study formed the initiation stage of wider, comprehensive and more frequent monitoring of occupational radiation exposures and long-term investigations into its accumulation patterns in our country.
Type testing the Model 6600 plus automatic TLD reader.
Velbeck, K J; Luo, L Z; Streetz, K L
2006-01-01
The Harshaw Model 6600 Plus is a reader with a capacity for 200 TLD cards or 800 extremity cards. The new unit integrates more functionality, and significantly automates the QC and calibration process compared to the Model 6600. The Model 6600 Plus was tested against the IEC 61066 (1991-2012) procedures using Harshaw TLD-700H and TLD-600H, LiF:Mg,Cu,P based TLD Cards. An overview of the type testing procedures is presented. These include batch homogeneity, detection threshold, reproducibility, linearity, self-irradiation, residue, light effects on dosemeter, light leakage to reader, voltage and frequency, dropping and reader stability. The new TLD reader was found to meet all the IEC criteria by large margins and appears well suited for whole body, extremity and environmental dosimetry applications, with a high degree of dosimetric performance.
Tissue-equivalent TL sheet dosimetry system for X- and gamma-ray dose mapping.
Nariyama, N; Konnai, A; Ohnishi, S; Odano, N; Yamaji, A; Ozasa, N; Ishikawa, Y
2006-01-01
To measure dose distribution for X- and gamma rays simply and accurately, a tissue-equivalent thermoluminescent (TL) sheet-type dosemeter and reader system were developed. The TL sheet is composed of LiF:Mg,Cu,P and ETFE polymer, and the thickness is 0.2 mm. For the TL reading, a square heating plate, 20 cm on each side, was developed, and the temperature distribution was measured with an infrared thermal imaging camera. As a result, linearity within 2% and the homogeneity within 3% were confirmed. The TL signal emitted is detected using a CCD camera and displayed as a spatial dose distribution. Irradiation using synchrotron radiation between 10 and 100 keV and (60)Co gamma rays showed that the TL sheet dosimetry system was promising for radiation dose mapping for various purposes.
On neutron-gamma mixed field dosimetry with LiF:Mg,Ti at radiation protection dose levels.
Weinstein, M; German, U; Alfassi, Z B
2006-01-01
The possibility of using the specific responses of the high temperature Peaks 6 and 7 and Peaks 4 and 5 to different LET radiations was mentioned in the past mainly for very high doses. The applicability of the two regions method for thermal neutrons--gamma ray mixed field dosimetry was investigated by analysing the response of LiF:Mg,Ti dosemeters irradiated to different ratios of thermal neutrons and gamma rays at radiation protection dose levels encountered in routine work conditions, up to approximately 50 mSv. The Region of Interest method was used to define the areas of the Peaks 4 + 5 and 6 + 7. We found that a simple algorithm can be used to determine with good accuracy the separate contributions of neutron and gamma doses.
CW-OSL measurement protocols using optical fibre Al2O3:C dosemeters.
Edmund, J M; Andersen, C E; Marckmann, C J; Aznar, M C; Akselrod, M S; Bøtter-Jensen, L
2006-01-01
A new system for in vivo dosimetry during radiotherapy has been introduced. Luminescence signals from a small crystal of carbon-doped aluminium oxide (Al2O3:C) are transmitted through an optical fibre cable to an instrument that contains optical filters, a photomultiplier tube and a green (532 nm) laser. The prime output is continuous wave optically stimulated luminescence (CW-OSL) used for the measurement of the integrated dose. We demonstrate a measurement protocol with high reproducibility and improved linearity, which is suitable for clinical dosimetry. A crystal-specific minimum pre-dose is necessary for signal stabilisation. Simple background subtraction only partially removes the residual signal present at long integration times. Instead, the measurement protocol separates the decay curve into three individual components and only the fast and medium components were used.
Dose distributions in phantoms irradiated in thermal columns of two different nuclear reactors.
Gambarini, G; Agosteo, S; Altieri, S; Bortolussi, S; Carrara, M; Gay, S; Nava, E; Petrovich, C; Rosi, G; Valente, M
2007-01-01
In-phantom dosimetry studies have been carried out at the thermal columns of a thermal- and a fast-nuclear reactor for investigating: (a) the spatial distribution of the gamma dose and the thermal neutron fluence and (b) the accuracy at which the boron concentration should be estimated in an explanted organ of a boron neutron capture therapy patient. The phantom was a cylinder (11 cm in diameter and 12 cm in height) of tissue-equivalent gel. Dose images were acquired with gel dosemeters across the axial section of the phantom. The thermal neutron fluence rate was measured with activation foils in a few positions of this phantom. Dose and fluence rate profiles were also calculated with Monte Carlo simulations. The trend of these profiles do not show significant differences for the thermal columns considered in this work.
Where Field Staff Get Information. Approaching the Electronic Times.
ERIC Educational Resources Information Center
Shih, Win-Yuan; Evans, James F.
1991-01-01
Top 3 information sources identified in a survey of 109 extension agents were extension publications, specialists, and personal files. Electronic sources such as satellite programing and bibliographic databases were used infrequently, because of lack of access, user friendliness, and ready applicability of information. (SK)
E-health strategies to support adherence
USDA-ARS?s Scientific Manuscript database
Adherence to healthy behaviors and self-care strategies is a concern among clinicians. E-health applications, such as the internet, personal communication devices, electronic health records and web portals, and electronic games, may be a way to provide health information in a way that is reliable, c...
78 FR 70244 - Electronic Interim Assistance Reimbursement Program
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-25
... SOCIAL SECURITY ADMINISTRATION 20 CFR Part 416 [Docket No. SSA-2011-0104] RIN 0960-AH45 Electronic Interim Assistance Reimbursement Program AGENCY: Social Security Administration. ACTION: Notice of.... We strongly urge you not to include in your comments any personal information, such as Social...
75 FR 62149 - Records Schedules; Availability and Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-07
... publications through the editorial process and capture bibliographic information for printed publications. 7... electronic data relating to persons of interest when the data relates to unique and significant intelligence... records of an electronic information system used to access intelligence and investigative data. 22...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-29
... person or organization may nominate qualified persons to be considered for appointment to this advisory committee. Individuals may self-nominate. Nominations should be submitted in electronic format (preferred) following the instructions for ``Nominating Experts to the Chemical Assessment Advisory Committee'' provided...
A Study of Personal Information Management Strategies for Online Faculty
ERIC Educational Resources Information Center
Kearns, Lorna R.; Frey, Barbara A.; Tomer, Christinger; Alman, Susan
2014-01-01
The literature suggests that personal information management is a serious challenge for many computer users. Online faculty are especially challenged because of the large number of electronic files necessitated by teaching online. Those who have experience in this environment may offer valuable insights regarding information management challenges…
Communication, Public Affairs Knowledge, and Older Persons.
ERIC Educational Resources Information Center
Kent, K. E.; Rush, Ramona R.
The impact of print and electronic media orientations upon the public affairs knowledge of older persons was investigated through interviews with 59 participants in a foster grandparents program, 68 participants in a retired senior volunteer program, and 23 members of a retired teachers association. Analysis of results indicated a clear pattern in…
Evaluating the Effectiveness of a Personal Response System in the Classroom
ERIC Educational Resources Information Center
Shaffer, Dennis M.; Collura, Michael J.
2009-01-01
We evaluated the effectiveness of the use of an electronic personal response system (or "clickers") during an introductory psychology lecture on perceptual constancy. We graphed and projected student responses to questions during the lecture onto a large-screen display in Microsoft PowerPoint. The distributions of answers corresponded…
Examining Advanced Technologies for Benefits to Persons with Sensory Impairments. Final Report.
ERIC Educational Resources Information Center
Hinton, Daniel E., Sr.
This final report describes activities and products of an 18-month study on improving access of persons with sensory impairments to media, telecommunications, electronic correspondence, and other communications devices by means of technological advancements. Ten scenarios were developed which describe potential applications of: (1) Braille devices…
Context as a Factor in Personal Information Management Systems.
ERIC Educational Resources Information Center
Barreau, Deborah K.
1995-01-01
Examines context as a factor in personal information management systems to suggest how it may influence classification decisions and ultimately retrieval. A study of seven managers is described that explored the factors that influence the way individuals manage electronic documents, and results are compared with an earlier study of physical…
Residential, personal, indoor, and outdoor sampling of particulate matter was conducted at a retirement center in the Towson area of northern Baltimore County in 1998. Concurrent sampling was conducted at a central community site. Computer-controlled scanning electron microsco...
Residential, personal, indoor, and outdoor sampling of particulate matter was conducted at a retirement center in the Towson area of northern Baltimore County in 1998. Concurrent sampling was conducted at a central community site. Computer-controlled scanning electron microsco...
The Challenges of Seeking Security While Respecting Privacy
NASA Astrophysics Data System (ADS)
Kantor, Paul B.; Lesk, Michael E.
Security is a concern for persons, organizations, and nations. For the individual members of organizations and nations, personal privacy is also a concern. The technologies for monitoring electronic communication are at the same time tools to protect security and threats to personal privacy. Participants in this workshop address the interrelation of personal privacy and national or societal security, from social, technical and legal perspectives. The participants represented industry, the academy and the United States Government. The issues addressed have become, if anything, even more pressing today than they were when the conference was held.
Razavi, Hessom; Baglin, Elizabeth; Sharangan, Pyrawy; Caruso, Emily; Tindill, Nicole; Griffin, Susan; Guymer, Robyn
2017-11-13
Improved vision self-monitoring tools are required for people at risk of neovascular complications from age related macular degeneration (AMD). to report the self-monitoring habits of participants with intermediate AMD using the Amsler grid chart, and the use of personal electronic devices and gameplay in this over 50 year old cohort. single-centre descriptive study carried out at the Centre for Eye Research (CERA), Melbourne, Australia. 140 participants over 50 years of age, with a diagnosis of intermediate AMD and best-corrected visual acuity (BCVA) of ≥6/12 in each eye. structured questionnaire survey of participants who were enrolled in natural history of AMD studies at CERA. frequency of vision self-monitoring using the Amsler grid chart, and frequency of general use of personal electronic devices and gameplay. Of 140 participants with mean age of 70.5 years, 83.6% used an Amsler grid chart, but only 39.3% used it once per week. Most participants (91.4%) used one or more personal electronic devices. Of these, over half (54.7%) played games on them, among whom 39% played games once a day. Of participants aged 50-69 years, 92% (95%CI 85.1-98.9) were willing to play a game to monitor their vision, compared to 78% (95%CI 69.0-87.0) of those aged 70 years and older (P < 0.05). a large proportion of AMD patients already use personal electronic devices. Gamification techniques are likely to increase compliance with self-monitoring, leading to earlier detection in the next generation of patients with neovascular AMD. © 2017 Royal Australian and New Zealand College of Ophthalmologists.
Email and All that Jazz: Training Staff to Use Electronic Communication Tools Professionally
ERIC Educational Resources Information Center
Stephens, Karen
2008-01-01
There are many benefits of e-mails. Through e-mail, a person can relay specific details to any number of "need to know" persons at the press of a "send" key at any time of day, without playing endless phone tag or waking someone up on the wrong side of the time zone. A person can also get "newsy" information out fast and save printing money, too.…
Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y.; Hu-Guo, C.; Husson, D.
2011-07-01
Despite a continuously increasing demand, neutron electronic personal dosimeters (EPDs) are still far from being completely established because their development is a very difficult task. A low-noise, ultra low power consumption CMOS pixel sensor for a future neutron personal dosimeter has been implemented in a 0.35 {mu}m CMOS technology. The prototype is composed of a pixel array for detection of charged particles, and the readout electronics is integrated on the same substrate for signal processing. The excess electrons generated by an impinging particle are collected by the pixel array. The charge collection time and the efficiency are the crucial pointsmore » of a CMOS detector. The 3-D device simulations using the commercially available Synopsys-SENTAURUS package address the detailed charge collection process. Within a time of 1.9 {mu}s, about 59% electrons created by the impact particle are collected in a cluster of 4 x 4 pixels with the pixel pitch of 80 {mu}m. A charge sensitive preamplifier (CSA) and a shaper are employed in the frond-end readout. The tests with electrical signals indicate that our prototype with a total active area of 2.56 x 2.56 mm{sup 2} performs an equivalent noise charge (ENC) of less than 400 e - and 314 {mu}W power consumption, leading to a promising prototype. (authors)« less
Cunningham, James; Ainsworth, John
2017-01-01
The rise of distributed ledger technology, initiated and exemplified by the Bitcoin blockchain, is having an increasing impact on information technology environments in which there is an emphasis on trust and security. Management of electronic health records, where both conformation to legislative regulations and maintenance of public trust are paramount, is an area where the impact of these new technologies may be particularly beneficial. We present a system that enables fine-grained personalized control of third-party access to patients' electronic health records, allowing individuals to specify when and how their records are accessed for research purposes. The use of the smart contract based Ethereum blockchain technology to implement this system allows it to operate in a verifiably secure, trustless, and openly auditable environment, features crucial to health information systems moving forward.
Cato, Kenrick D; Bockting, Walter; Larson, Elaine
2016-07-01
Widespread availability of electronic health records coupled with sophisticated statistical methods offer great potential for a variety of applications for health and disease surveillance, developing predictive models and advancing decision support for clinicians. However, use of "big data" mining and discovery techniques has also raised ethical issues such as how to balance privacy and autonomy with the wider public benefits of data sharing. Furthermore, electronic data are being increasingly used to identify individual characteristics, which can be useful for clinical prediction and management, but were not previously disclosed to a clinician. This process in computer parlance is called electronic phenotyping, and has a number of ethical implications. Using the Belmont Report's principles of respect for persons, beneficence, and justice as a framework, we examined the ethical issues posed by electronic phenotyping. Ethical issues identified include the ability of the patient to consent for the use of their information, the ability to suppress pediatric information, ensuring that the potential benefits justify the risks of harm to patients, and acknowledging that the clinician's biases or stereotypes, conscious or unintended, may become a factor in the therapeutic interaction. We illustrate these issues with two vignettes, using the person characteristic of gender minority status (i.e., transgender identity) and health history characteristic of substance abuse. Data mining has the potential to uncover patient characteristics previously obscured, which can provide clinicians with beneficial clinical information. Hence, ethical guidelines must be updated to ensure that electronic phenotyping supports the principles of respect for persons, beneficence, and justice. © The Author(s) 2016.
48 CFR 23.705 - Electronic products environmental assessment tool.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REGULATION SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES... standard for personal computer products— (i) Was issued by the Institute of Electrical and Electronics.... 104-113, the “National Technology Transfer and Advancement Act of 1995”, (see 11.102(c)); (iii) Meets...
48 CFR 23.704 - Electronic products environmental assessment tool.
Code of Federal Regulations, 2011 CFR
2011-10-01
... REGULATION SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES... standard for personal computer products— (i) Was issued by the Institute of Electrical and Electronics.... 104-113, the “National Technology Transfer and Advancement Act of 1995”, (see 11.102(c)); (iii) Meets...
48 CFR 23.704 - Electronic products environmental assessment tool.
Code of Federal Regulations, 2012 CFR
2012-10-01
... REGULATION SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES... standard for personal computer products— (i) Was issued by the Institute of Electrical and Electronics.... 104-113, the “National Technology Transfer and Advancement Act of 1995”, (see 11.102(c)); (iii) Meets...
Personal technology use by U.S. military service members and veterans: an update.
Bush, Nigel E; Wheeler, William M
2015-04-01
Although personal electronic devices, such as mobile phones, computers, and tablets, increasingly are being leveraged as vehicles for health in the civilian world, almost nothing is known about personal technology use in the U.S. military. In 2012 we conducted a unique survey of personal technologies used by U.S. military service members. However, with the rapidly growing sophistication of personal technology and changes in consumer habits, that knowledge must be continuously updated to be useful. Accordingly, we recently surveyed new samples of active duty service members, National Guard and Reserve, and veterans. We collected data by online surveys in 2013 from 239 active, inactive, and former service members. Online surveys were completed in-person via laptop computers at a large military installation and remotely via Web-based surveys posted on the Army Knowledge Online Web site and on a Defense Center Facebook social media channel. We measured high rates of personal technology use by service members at home across popular electronic media. The most dramatic change since our earlier survey was the tremendous increase in mobile phone use at home for a wide variety of purposes. Participants also reported moderate non-work uses of computers and tablets while on recent deployment to Iraq and Afghanistan, but almost no mobile phone use, ostensibly because of military restrictions in the war zone. These latest results will enable researchers and technology developers target their efforts on the most promising and popular technologies for psychological health in the military.
Phua, Joe; Tinkham, Spencer
2016-01-01
This study examined the joint influence of spokesperson type in obesity public service announcements (PSAs) and viewer weight on diet intention, exercise intention, information seeking, and electronic word-of-mouth (eWoM) intention. Results of a 2 (spokesperson type: real person vs. actor) × 2 (viewer weight: overweight vs. non-overweight) between-subjects experiment indicated that overweight viewers who saw the PSA featuring the real person had the highest diet intention, exercise intention, information seeking, and eWoM intention. Parasocial interaction was also found to mediate the relationships between spokesperson type/viewer weight and two of the dependent variables: diet intention and exercise intention. In addition, viewers who saw the PSA featuring the real person rated the spokesperson as significantly higher on source credibility (trustworthiness, competence, and goodwill) than those who saw the PSA featuring the actor.
Daily patterns of communication and contact between Italian early adolescents and their friends.
Baiocco, Roberto; Laghi, Fiorenzo; Schneider, Barry H; Dalessio, Maria; Amichai-Hamburger, Yair; Coplan, Robert J; Koszycki, Diana; Flament, Martine
2011-01-01
The goal of the present study was to explore patterns of communication between adolescents and their friends across both "online" and "in-person" contexts. The participants were adolescents (n = 727) aged 11-16 years attending middle schools in urban and rural areas of Italy. Participants completed daily logs of their in-person and online contacts with friends for 20 consecutive school days. Girls reported more total contacts with their friends than did boys as well as friendships that were closer and more intimate. However, boys indicated more contact than girls via electronic communication and online. Contacts with peers in general were less frequent among the older participants, perhaps because of increasing academic demands. Participants who complemented in-person contact with friends with electronic contact were less lonely than their counterparts who were less versatile in accessing different modalities of making contact with friends.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-28
... removal from the list of Specially Designated Nationals and Blocked Persons (``SDN List'') of the... INFORMATION: Electronic and Facsimile Availability The SDN List and additional information concerning OFAC are... service at (202) 622-0077. Background On September 21, 2011, OFAC unblocked and removed from the SDN List...
49 CFR 172.201 - Preparation and retention of shipping papers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... service provider, identify the person (by name or contract number) who has a contractual agreement with... person who provides a shipping paper must retain a copy of the shipping paper required by § 172.200(a), or an electronic image thereof, that is accessible at or through its principal place of business and...
Code of Federal Regulations, 2012 CFR
2012-01-01
... determined by DACO. Central filing system (CFS) means an electronic system operated and maintained by a... inclusion in a provider's CFS. Person means a person as set forth in 1 U.S.C. 1, a State; or a political... concerning the provider's operation or maintenance of a CFS. Receipt means a warehouse receipt issued in...
The Use of Personal Data Assistants in Early Childhood Assessment
ERIC Educational Resources Information Center
Ledoux, Michael W.; Yoder, Noreen N.; Hanes, Barbara
2010-01-01
Four early childhood education teachers, two veteran and two newer teachers, were asked to pilot the use of handheld Personal Data Assistants loaded with Childchart assessment software. The participants were observed in their use of the electronic devices for monitoring student performance and interviewed regarding the use of the devices and their…
38 CFR 74.12 - What must a concern submit to apply for VetBiz VIP Verification Program?
Code of Federal Regulations, 2010 CFR
2010-07-01
... personal and business tax returns, payroll records and personal history statements. An applicant must also...' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) VETERANS SMALL BUSINESS REGULATIONS Application... dispatches the electronic forms, the applicant must also retain on file at the principal place of business a...
Libraries without Resources: Towards Personal Collections.
ERIC Educational Resources Information Center
Savenije, Bas; Grygierczyk, Natalia
The main function of the library of the future is to provide access to electronic sources stored elsewhere. In order to comply with the users' needs, therefore, flexible license scenarios are necessary. Another future function of the library will be to set up and maintain a personal alerting system and to assist users in organizing their own…
Ideas for Using an Electronic Classroom in Intermediate French.
ERIC Educational Resources Information Center
Deimling, Katherine
2003-01-01
Describes lessons designed around two types of French Web sites: matchmaking sites with personal ads and the official site of the Cannes Film Festival. Goals are to motivate students with authentic material in French and to improve their ability to describe people according to various factors: personality, nationality, professions, and appearance.…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-27
... using personal laptop computers and discussing airline crew scheduling procedures. Using personal laptop.... Distracted Driving Impacts All Transportation Modes 1. Aviation 2. Rail 3. Motorcoach G. Studies 1. FRA Study 1. National Motor Vehicle Crash Causation Survey (NMVCCS) 2. 100-Car Naturalistic Driving Study 3...
Shi, Yunzhou; Manco, Megan; Moyal, Dominique; Huppert, Gil; Araki, Hitoshi; Banks, Anthony; Joshi, Hemant; McKenzie, Richard; Seewald, Alex; Griffin, Guy; Sen-Gupta, Ellora; Wright, Donald; Bastien, Philippe; Valceschini, Florent; Seité, Sophie; Wright, John A; Ghaffari, Roozbeh; Rogers, John; Balooch, Guive; Pielak, Rafal M
2018-01-01
Excessive ultraviolet (UV) radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application.
MyDiabetesMyWay: An Evolving National Data Driven Diabetes Self-Management Platform.
Wake, Deborah J; He, Jinzhang; Czesak, Anna Maria; Mughal, Fezan; Cunningham, Scott G
2016-09-01
MyDiabetesMyWay (MDMW) is an award-wining national electronic personal health record and self-management platform for diabetes patients in Scotland. This platform links multiple national institutional and patient-recorded data sources to provide a unique resource for patient care and self-management. This review considers the current evidence for online interventions in diabetes and discusses these in the context of current and ongoing developments for MDMW. Evaluation of MDMW through patient reported outcomes demonstrates a positive impact on self-management. User feedback has highlighted barriers to uptake and has guided platform evolution from an education resource website to an electronic personal health record now encompassing remote monitoring, communication tools and personalized education links. Challenges in delivering digital interventions for long-term conditions include integration of data between institutional and personal recorded sources to perform big data analytics and facilitating technology use in those with disabilities, low digital literacy, low socioeconomic status and in minority groups. The potential for technology supported health improvement is great, but awareness and adoption by health workers and patients remains a significant barrier. © 2016 Diabetes Technology Society.
Wake, Deborah J.; He, Jinzhang; Czesak, Anna Maria; Mughal, Fezan; Cunningham, Scott G.
2016-01-01
MyDiabetesMyWay (MDMW) is an award-wining national electronic personal health record and self-management platform for diabetes patients in Scotland. This platform links multiple national institutional and patient-recorded data sources to provide a unique resource for patient care and self-management. This review considers the current evidence for online interventions in diabetes and discusses these in the context of current and ongoing developments for MDMW. Evaluation of MDMW through patient reported outcomes demonstrates a positive impact on self-management. User feedback has highlighted barriers to uptake and has guided platform evolution from an education resource website to an electronic personal health record now encompassing remote monitoring, communication tools and personalized education links. Challenges in delivering digital interventions for long-term conditions include integration of data between institutional and personal recorded sources to perform big data analytics and facilitating technology use in those with disabilities, low digital literacy, low socioeconomic status and in minority groups. The potential for technology supported health improvement is great, but awareness and adoption by health workers and patients remains a significant barrier. PMID:27162192
Shi, Yunzhou; Manco, Megan; Moyal, Dominique; Huppert, Gil; Araki, Hitoshi; Banks, Anthony; Joshi, Hemant; McKenzie, Richard; Seewald, Alex; Griffin, Guy; Sen-Gupta, Ellora; Wright, Donald; Bastien, Philippe; Valceschini, Florent; Seité, Sophie; Wright, John A.; Ghaffari, Roozbeh; Rogers, John; Balooch, Guive
2018-01-01
Excessive ultraviolet (UV) radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application. PMID:29293664
An eMERGE Clinical Center at Partners Personalized Medicine
Smoller, Jordan W.; Karlson, Elizabeth W.; Green, Robert C.; Kathiresan, Sekar; MacArthur, Daniel G.; Talkowski, Michael E.; Murphy, Shawn N.; Weiss, Scott T.
2016-01-01
The integration of electronic medical records (EMRs) and genomic research has become a major component of efforts to advance personalized and precision medicine. The Electronic Medical Records and Genomics (eMERGE) network, initiated in 2007, is an NIH-funded consortium devoted to genomic discovery and implementation research by leveraging biorepositories linked to EMRs. In its most recent phase, eMERGE III, the network is focused on facilitating implementation of genomic medicine by detecting and disclosing rare pathogenic variants in clinically relevant genes. Partners Personalized Medicine (PPM) is a center dedicated to translating personalized medicine into clinical practice within Partners HealthCare. One component of the PPM is the Partners Healthcare Biobank, a biorepository comprising broadly consented DNA samples linked to the Partners longitudinal EMR. In 2015, PPM joined the eMERGE Phase III network. Here we describe the elements of the eMERGE clinical center at PPM, including plans for genomic discovery using EMR phenotypes, evaluation of rare variant penetrance and pleiotropy, and a novel randomized trial of the impact of returning genetic results to patients and clinicians. PMID:26805891
An eMERGE Clinical Center at Partners Personalized Medicine.
Smoller, Jordan W; Karlson, Elizabeth W; Green, Robert C; Kathiresan, Sekar; MacArthur, Daniel G; Talkowski, Michael E; Murphy, Shawn N; Weiss, Scott T
2016-01-20
The integration of electronic medical records (EMRs) and genomic research has become a major component of efforts to advance personalized and precision medicine. The Electronic Medical Records and Genomics (eMERGE) network, initiated in 2007, is an NIH-funded consortium devoted to genomic discovery and implementation research by leveraging biorepositories linked to EMRs. In its most recent phase, eMERGE III, the network is focused on facilitating implementation of genomic medicine by detecting and disclosing rare pathogenic variants in clinically relevant genes. Partners Personalized Medicine (PPM) is a center dedicated to translating personalized medicine into clinical practice within Partners HealthCare. One component of the PPM is the Partners Healthcare Biobank, a biorepository comprising broadly consented DNA samples linked to the Partners longitudinal EMR. In 2015, PPM joined the eMERGE Phase III network. Here we describe the elements of the eMERGE clinical center at PPM, including plans for genomic discovery using EMR phenotypes, evaluation of rare variant penetrance and pleiotropy, and a novel randomized trial of the impact of returning genetic results to patients and clinicians.
Non-Self-Maintained Discharge Application for Fuel Activation
2010-09-21
provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently ...voltage accelerating tube (1); - An injector of electrons with the thermo emission heated cathode (2); - The high-voltage rectifier (3); - A...auxiliary systems of the accelerator. The electron injector (2) is supplied by the thermo - emission cathode, allowing to generate an electron
Factors Associated with Young People's Successful Resolution of Distressing Electronic Harassment
ERIC Educational Resources Information Center
Fenaughty, John; Harre, Niki
2013-01-01
Electronic harassment is a pervasive phenomenon among young people, however relatively little is known about actions that targets of harassment may undertake to manage such abuse, and whether particular actions and personal characteristics are associated with successful resolution of such harassment. This mixed methods research identified whether…
78 FR 6830 - Renewal of Approved Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-31
... of information from persons who seek authorization for free use of mineral or vegetative materials...: Comments may be submitted by mail, fax, or electronic mail. Mail: U.S. Department of the Interior, Bureau.... Fax: to Jean Sonneman at 202-245-0050. Electronic mail: [email protected] . Please indicate ``Attn...
Policies Target Teacher-Student Cyber Talk
ERIC Educational Resources Information Center
Ash, Katie
2009-01-01
Teachers in Louisiana may soon think twice before sending a text message or e-mail to a student from a personal electronic device. A new state law requires all Louisiana districts to implement policies requiring documentation of every electronic interaction between teachers and students through a nonschool-issued device, such as a personal…
ELECTRONIC BUSINESS DATA PROCESSING PERIPHERAL EQUIPMENT OCCUPATIONS, SUGGESTED CURRICULA.
ERIC Educational Resources Information Center
Office of Education (DHEW), Washington, DC.
VOCATIONAL CURRICULUMS ARE SUGGESTED FOR EIGHT ELECTRONIC BUSINESS DATA PROCESSING OCCUPATIONS AS A GUIDE TO TRAINING UNEMPLOYED AND UNDEREMPLOYED PERSONS. THE COURSE OUTLINES AND OTHER MATERIAL WERE PREPARED BY STAFF MEMBERS OF THE INFORMATION AND TRAINING SERVICES DIVISION OF MCGRAW-HILL, INC. CONSULTANTS INCLUDED DATA PROCESSING TRAINING…
47 CFR 64.3100 - Restrictions on mobile service commercial messages.
Code of Federal Regulations, 2011 CFR
2011-10-01
... advertise or promote a product, service, or Internet website of the person or entity forwarding the message... subscriber; (2) Include a functioning return electronic mail address or other Internet-based mechanism that... communications made to the electronic mail address, other Internet-based mechanism or, if applicable, other...
ERIC Educational Resources Information Center
Mizell, Al P.; Centini, Barry M.
The role of telecommunications in establishing the electronic classroom in distance education is illustrated. Using a computer-based doctoral program and the UNIX operating system as an example, how a personal computer and modem may be combined with a telephone line for instructional delivery is described. A number of issues must be addressed in…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-26
... Certain Products Containing Interactive Program Guide and Parental Controls Technology, DN 2763; the... guide and parental controls technology. The complaint names as respondents Toshiba Corp. of Minato-ku.../handbook_on_electronic_filing.pdf ). Persons with questions regarding electronic filing should contact the...
18 CFR 375.302 - Delegations to the Secretary.
Code of Federal Regulations, 2013 CFR
2013-04-01
... other persons to file required reports, data, and information and to do other acts required to be done... appropriate hydroelectric project license article upon application by the licensee to reflect the specified... electronic media or via other electronic means. (aa) Issue a notice that the Commission will not further...
18 CFR 375.302 - Delegations to the Secretary.
Code of Federal Regulations, 2014 CFR
2014-04-01
... other persons to file required reports, data, and information and to do other acts required to be done... appropriate hydroelectric project license article upon application by the licensee to reflect the specified... electronic media or via other electronic means. (aa) Issue a notice that the Commission will not further...
21 CFR 11.10 - Controls for closed systems.
Code of Federal Regulations, 2014 CFR
2014-04-01
... controls designed to ensure the authenticity, integrity, and, when appropriate, the confidentiality of... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Controls for closed systems. 11.10 Section 11.10... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.10 Controls for closed systems. Persons who use...
21 CFR 11.10 - Controls for closed systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
... controls designed to ensure the authenticity, integrity, and, when appropriate, the confidentiality of... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Controls for closed systems. 11.10 Section 11.10... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.10 Controls for closed systems. Persons who use...
21 CFR 11.10 - Controls for closed systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... controls designed to ensure the authenticity, integrity, and, when appropriate, the confidentiality of... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Controls for closed systems. 11.10 Section 11.10... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.10 Controls for closed systems. Persons who use...
21 CFR 11.10 - Controls for closed systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... controls designed to ensure the authenticity, integrity, and, when appropriate, the confidentiality of... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Controls for closed systems. 11.10 Section 11.10... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.10 Controls for closed systems. Persons who use...
21 CFR 11.10 - Controls for closed systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... controls designed to ensure the authenticity, integrity, and, when appropriate, the confidentiality of... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Controls for closed systems. 11.10 Section 11.10... RECORDS; ELECTRONIC SIGNATURES Electronic Records § 11.10 Controls for closed systems. Persons who use...
Electronic Resources and the Education of History Professionals
ERIC Educational Resources Information Center
Mulligan, William H., Jr.
2001-01-01
The transforming effects of the tremendous advances in technology that have reshaped the economy and many other elements of American society have had an equally profound impact on historical agencies. The personal computer, the Internet, and associated electronic communications developments have already transformed the museum and historical agency…
78 FR 20175 - Proposed Collection; Comment Request for Information Collection tools.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-03
... Form 8879-PE, IRS e-file Signature Authorization for Form 1065; Revenue Procedure 2009-32, Reliance... e-file Signature Authorization for Form 1065. OMB Number: 1545-2042. Form Number: 8879-PE. Abstract... personal identification number (PIN) to electronically sign a partnership's electronic income tax return...
Using Electronic Response Systems in Economics Classes
ERIC Educational Resources Information Center
Ghosh, Sucharita; Renna, Francesco
2009-01-01
College instructors and students participated in a pilot project at the University of Akron to enhance student learning through the use of a common teaching pedagogy, peer instruction. The teaching pedagogy was supported by the use of technology, an electronic personal response system, which recorded student responses. The authors report their…
Code of Federal Regulations, 2013 CFR
2013-07-01
... plaques; (4) For electronic media, motion picture film, video tape and other audiovisual media prepared by...) On electronic media, motion picture film, video tape, and other audiovisual media prepared by or for... seal, replica, reproduction or embossing seal is punishable under 18 U.S.C. 506. (g) Any person using...
Code of Federal Regulations, 2011 CFR
2011-07-01
... plaques; (4) For electronic media, motion picture film, video tape and other audiovisual media prepared by...) On electronic media, motion picture film, video tape, and other audiovisual media prepared by or for... seal, replica, reproduction or embossing seal is punishable under 18 U.S.C. 506. (g) Any person using...
Code of Federal Regulations, 2012 CFR
2012-07-01
... plaques; (4) For electronic media, motion picture film, video tape and other audiovisual media prepared by...) On electronic media, motion picture film, video tape, and other audiovisual media prepared by or for... seal, replica, reproduction or embossing seal is punishable under 18 U.S.C. 506. (g) Any person using...
Code of Federal Regulations, 2010 CFR
2010-07-01
... plaques; (4) For electronic media, motion picture film, video tape and other audiovisual media prepared by...) On electronic media, motion picture film, video tape, and other audiovisual media prepared by or for... seal, replica, reproduction or embossing seal is punishable under 18 U.S.C. 506. (g) Any person using...
Code of Federal Regulations, 2014 CFR
2014-07-01
... plaques; (4) For electronic media, motion picture film, video tape and other audiovisual media prepared by...) On electronic media, motion picture film, video tape, and other audiovisual media prepared by or for... seal, replica, reproduction or embossing seal is punishable under 18 U.S.C. 506. (g) Any person using...
Hartzler, Andrea; McCarty, Catherine A.; Rasmussen, Luke V.; Williams, Marc S.; Brilliant, Murray; Bowton, Erica A.; Clayton, Ellen Wright; Faucett, William A.; Ferryman, Kadija; Field, Julie R.; Fullerton, Stephanie M.; Horowitz, Carol R.; Koenig, Barbara A.; McCormick, Jennifer B.; Ralston, James D.; Sanderson, Saskia C.; Smith, Maureen E.; Trinidad, Susan Brown
2014-01-01
Integrating genomic information into clinical care and the electronic health record can facilitate personalized medicine through genetically guided clinical decision support. Stakeholder involvement is critical to the success of these implementation efforts. Prior work on implementation of clinical information systems provides broad guidance to inform effective engagement strategies. We add to this evidence-based recommendations that are specific to issues at the intersection of genomics and the electronic health record. We describe stakeholder engagement strategies employed by the Electronic Medical Records and Genomics Network, a national consortium of US research institutions funded by the National Human Genome Research Institute to develop, disseminate, and apply approaches that combine genomic and electronic health record data. Through select examples drawn from sites of the Electronic Medical Records and Genomics Network, we illustrate a continuum of engagement strategies to inform genomic integration into commercial and homegrown electronic health records across a range of health-care settings. We frame engagement as activities to consult, involve, and partner with key stakeholder groups throughout specific phases of health information technology implementation. Our aim is to provide insights into engagement strategies to guide genomic integration based on our unique network experiences and lessons learned within the broader context of implementation research in biomedical informatics. On the basis of our collective experience, we describe key stakeholder practices, challenges, and considerations for successful genomic integration to support personalized medicine. PMID:24030437
Electronic Data Collection Options for Practice-Based Research Networks
Pace, Wilson D.; Staton, Elizabeth W.
2005-01-01
PURPOSE We wanted to describe the potential benefits and problems associated with selected electronic methods of collecting data within practice-based research networks (PBRNs). METHODS We considered a literature review, discussions with PBRN researchers, industry information, and personal experience. This article presents examples of selected PBRNs’ use of electronic data collection. RESULTS Collecting research data in the geographically dispersed PBRN environment requires considerable coordination to ensure completeness, accuracy, and timely transmission of the data, as well as a limited burden on the participants. Electronic data collection, particularly at the point of care, offers some potential solutions. Electronic systems allow use of transparent decision algorithms and improved data entry and data integrity. These systems may improve data transfer to the central office as well as tracking systems for monitoring study progress. PBRNs have available to them a wide variety of electronic data collection options, including notebook computers, tablet PCs, personal digital assistants (PDAs), and browser-based systems that operate independent of or over the Internet. Tablet PCs appear particularly advantageous for direct patient data collection in an office environment. PDAs work well for collecting defined data elements at the point of care. Internet-based systems work well for data collection that can be completed after the patient visit, as most primary care offices do not support Internet connectivity in examination rooms. CONCLUSIONS When planning to collect data electronically, it is important to match the electronic data collection method to the study design. Focusing an inappropriate electronic data collection method onto users can interfere with accurate data gathering and may also anger PBRN members. PMID:15928215
Electronic data collection options for practice-based research networks.
Pace, Wilson D; Staton, Elizabeth W
2005-01-01
We wanted to describe the potential benefits and problems associated with selected electronic methods of collecting data within practice-based research networks (PBRNs). We considered a literature review, discussions with PBRN researchers, industry information, and personal experience. This article presents examples of selected PBRNs' use of electronic data collection. Collecting research data in the geographically dispersed PBRN environment requires considerable coordination to ensure completeness, accuracy, and timely transmission of the data, as well as a limited burden on the participants. Electronic data collection, particularly at the point of care, offers some potential solutions. Electronic systems allow use of transparent decision algorithms and improved data entry and data integrity. These systems may improve data transfer to the central office as well as tracking systems for monitoring study progress. PBRNs have available to them a wide variety of electronic data collection options, including notebook computers, tablet PCs, personal digital assistants (PDAs), and browser-based systems that operate independent of or over the Internet. Tablet PCs appear particularly advantageous for direct patient data collection in an office environment. PDAs work well for collecting defined data elements at the point of care. Internet-based systems work well for data collection that can be completed after the patient visit, as most primary care offices do not support Internet connectivity in examination rooms. When planning to collect data electronically, it is important to match the electronic data collection method to the study design. Focusing an inappropriate electronic data collection method onto users can interfere with accurate data gathering and may also anger PBRN members.
Status of eye lens radiation dose monitoring in European hospitals.
Carinou, Eleftheria; Ginjaume, Merce; O'Connor, Una; Kopec, Renata; Sans Merce, Marta
2014-12-01
A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.
Comparing Geant4 hadronic models for the WENDI-II rem meter response function.
Vanaudenhove, T; Dubus, A; Pauly, N
2013-01-01
The WENDI-II rem meter is one of the most popular neutron dosemeters used to assess a useful quantity of radiation protection, namely the ambient dose equivalent. This is due to its high sensitivity and its energy response that approximately follows the conversion function between neutron fluence and ambient dose equivalent in the range of thermal to 5 GeV. The simulation of the WENDI-II response function with the Geant4 toolkit is then perfectly suited to compare low- and high-energy hadronic models provided by this Monte Carlo code. The results showed that the thermal treatment of hydrogen in polyethylene for neutron <4 eV has a great influence over the whole detector range. Above 19 MeV, both Bertini Cascade and Binary Cascade models show a good correlation with the results found in the literature, while low-energy parameterised models are not suitable for this application.
In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.
Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J
2004-01-01
In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.
Novel spectrometers for environmental dose rate monitoring.
Kessler, P; Behnke, B; Dabrowski, R; Dombrowski, H; Röttger, A; Neumaier, S
2018-07-01
A new generation of dosemeters, based on the scintillators LaBr 3 , CeBr 3 and SrI 2 , read out with conventional photomultipliers, to be used in the field of environmental gamma-radiation monitoring, was investigated. The main features of these new instruments and especially their outdoor performance, studied by long-term investigations under real weather conditions, are presented. The systems were tested at the reference sites for environmental radiation of the Physikalisch-Technische Bundesanstalt. The measurements are compared with that of well characterized classical dose rate reference instruments to demonstrate the suitability of new spectrometers for environmental dose rate monitoring even in adverse weather conditions. Their potential to replace the (mainly Geiger Müller based) dose rate meters operated in about 5000 European early waning network stations as well as in environmental radiation monitoring in general is shown. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Evaluation of organ doses in CT examinations with an infant anthropomorphic phantom.
Fujii, K; Akahane, K; Miyazaki, O; Horiuchi, T; Shimada, A; Nagmatsu, H; Yamauchi, M; Yamauchi-Kawaura, C; Kawasaki, T
2011-09-01
The aim of this study is to evaluate organ doses in infant CT examinations with multi-detector row CT scanners. Radiation doses were measured with radiophotoluminescence glass dosemeters set in various organ positions within a 1-y-old child anthropomorphic phantom and organ doses were evaluated from the measurement values. Doses for tissues or organs within the scan range were 28-36 mGy in an infant head CT, 3-11 mGy in a chest CT, 5-11 mGy in an abdominal-pelvic CT and 2-14 mGy in a cardiac CT. The doses varied by the differences in the types of CT scanners and scan parameters used at each medical facility. Compared with those for children of various ages, the doses in an infant CT protocol were found to be similar to or slightly smaller than those in a paediatric CT for 5- or 6-y-old children.
Jain, M; Bøtter-Jensen, L; Murray, A S; Jungner, H
2002-01-01
In the assessment of dose received from a nuclear accident, considerable attention has been paid to retrospective dosimetry using heated materials such as household ceramics and bricks. However, unheated materials such as mortar and concrete are more commonly found in industrial sites and particularly in nuclear installations. These materials contain natural dosemeters such as quartz, which usually is less sensitive than its heated counterpart. The potential of quartz extracted from mortar in a wall of a low-level radioactive-waste storage facility containing distributed sources of 60Co and 137Cs has been investigated. Dose-depth proliles based on small aliquots and single grains from the quartz extracted from the mortar samples are reported here. These are compared with results from heated quartz and polymineral fine grains extracted from an adjacent brick, and the integrated dose recorded by environmental TLDs.
1988-01-29
Electronic Origin of Pentacene in p-Terphenyl by T. P. Carter, M. Manavi, and W. E. Moerner Prepared for Publication inDTIC Journal of Chemical Physics...Classification) Statistical Fine Structure in the Inhomogeneously Broadened Electronic Origin of Pentacene in p-Terphenyl 12. PERSONAL AUTHOR(S) T. P...of pentacene in p-terphenyl using laser FM spectroscopy. Statistical fine structure is time-independent structure on the inhomogeneous line caused by
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voigts-Rhetz, P von; Zink, K; University Hospital Giessen-Marburg, Marburg
2016-06-15
Purpose: National and international dosimetry protocols assume a position accuracy for ionization chambers of less than 0.2mm. To follow this precept the manufacturer PTW-Freiburg introduced a positioning assistance system (TRUFIX) for their particular ion chambers. Aim of this study is an experimental investigation of the positioning uncertainties for ROOS-type ionization chambers. Methods: For all measurements a linear accelerator Elekta Synergie was used. The experiments were performed in a water-phantom. To collimate the electron beam a 10×10cm{sup 2} applicator was installed. All measured depth dose curves were normalized to their maximum. In all cases the TRUFIX system was applied for chambermore » positioning. For the first measurement series, to determine the positioning reproducibility of a ROOS chamber, one person placed the chamber three times in a 6 MeV electron beam. The mean value of this three measurements was the reference for further six random persons who repeated this procedure. The results were compared for different depths (R{sub 50}, z{sub ref} and R{sub p}). To investigate the impact of different individual chambers of the same type 10 different ROOS chambers were placed by the same person in a 6, 12 and 18MeV electron beam and the measured reference depths z{sub ref} were compared. Results: The absolute positioning reproducibility is less than 0.1mm for the same person. The positioning uncertainties are increasing up to +/−0.3mm if different persons perform the chamber’s positioning within the water phantom. The comparison of the 10 different ROOS chambers resulted in reference depths z{sub ref} with deviations in the range of +/−0.45mm for all energies. Conclusion: The position accuracy of 0.2mm can be fulfilled with the TRUFIX system. The comparison of the 10 different ROOS ionization chambers showed noticeable deviations in the determined reference depth. The impact of a positioning uncertainty of about 0.3–0.4mm on the total perturbation correction will be considered.« less
GSM-PKI solution enabling secure mobile communications.
Jelekäinen, Pekka
2004-03-31
Because of its wide distribution and ease of use, the mobile phone, as a reliable personal communications channel, offers an excellent basis for the provision of reliable electronic communications services. In Finland, ca. 75% of the citizens have a mobile phone and, at present and most likely also in the future, it is the most widely spread service channel allowing reliable electronic communications. Despite the restricted functions of the mobile phone, the citizens can use the phone also as a communications medium. In 2001, the Finns sent over 1 billion SMS messages. In Finland, TeliaSonera Finland Oyi and the Population Register Centre (PRC) have closed a co-operation agreement with the aim of creating a mobile phone service for the electronic identification of a person. The co-operation launched is a significant development project from the perspective of the citizens. As a result, the consumers will have a new alternative for reliable electronic communications and commerce in data networks in addition to the electronic identification card. In the future, it will be possible to use the services of both public administration and the private sector by means of a mobile phone more reliably than before, without a physical visit, e.g. to a health centre or to another provider of healthcare services. The possibility of identification and signature by a mobile phone allows an easier provision of versatile services irrespective of time and place, because, in addition to voice, text message, and WAP functions, the service can be utilised also in communications services through the Internet, in which case, the mobile phone acts like a card reader. From the perspective of reliable personal mobile communications, the healthcare sector is one of the most significant and challenging application areas.
Luchenski, Serena; Balasanthiran, Anjali; Marston, Cicely; Sasaki, Kaori; Majeed, Azeem; Bell, Derek; Reed, Julie E
2012-05-23
Immediate access to patients' complete health records via electronic databases could improve healthcare and facilitate health research. However, the possible benefits of a national electronic health records (EHR) system must be balanced against public concerns about data security and personal privacy. Successful development of EHR requires better understanding of the views of the public and those most affected by EHR: users of the National Health Service. This study aims to explore the correlation between personal healthcare experience (including number of healthcare contacts and number and type of longer term conditions) and views relating to development of EHR for healthcare, health services planning and policy and health research. A multi-site cross-sectional self-complete questionnaire designed and piloted for use in waiting rooms was administered to patients from randomly selected outpatients' clinics at a university teaching hospital (431 beds) and general practice surgeries from the four primary care trusts within the catchment area of the hospital. All patients entering the selected outpatients clinics and general practice surgeries were invited to take part in the survey during August-September 2011. Statistical analyses will be conducted using descriptive techniques to present respondents' overall views about electronic health records and logistic regression to explore associations between these views and participants' personal circumstances, experiences, sociodemographics and more specific views about electronic health records. The study design and implementation were successful, resulting in unusually high response rates and overall recruitment (85.5%, 5336 responses). Rates for face-to-face recruitment in previous work are variable, but typically lower (mean 76.7%, SD 20). We discuss details of how we collected the data to provide insight into how we obtained this unusually high response rate.
Cato, Kenrick D; Bockting, Walter; Larson, Elaine
2016-01-01
Background Widespread availability of large data sets through warehousing of electronic health records coupled with increasingly sophisticated information technology and related statistical methods offer great potential for a variety of applications for health and disease surveillance, developing predictive models and advancing decision support for clinicians. However, use of such ‘big data’ mining and discovery techniques has also raised ethical issues such as how to balance privacy and autonomy with the wider public benefits of data sharing. More specifically, electronic data are being increasingly used to identify individual characteristics which can be useful for clinical prediction and management, but that were not previously disclosed to a clinician. This process in computer parlance is called electronic phenotyping, and has a number of ethical implications. Approach Using the Belmont Report’s principles of respect for persons, beneficence, and justice as a framework, we examined the ethical issues posed by electronic phenotyping. Findings Ethical issues identified include the ability of the patient to consent for the use of their information, the ability to suppress pediatric information, ensuring that the potential benefits justify the risks of harm to patients, and acknowledging that the clinician’s biases or stereotypes, conscious or unintended, may also become a factor in the therapeutic interaction. We illustrate these issues with two vignettes, using the person characteristic of gender minority status (i.e., transgender identity) and the health history characteristic of substance abuse. Conclusion Big data mining has the potential to uncover patient characteristics previously obscured which can provide clinicians with beneficial clinical information. Hence, ethical guidelines must be updated to ensure that electronic phenotyping supports the principles of respect for persons, beneficence, and justice. PMID:27534587
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-25
... to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-30
... to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... link to log on and submit the intervention or protests. Persons unable to file electronically should... protest should file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-20
... link to log on and submit the intervention or protests. Persons unable to file electronically should... protest should file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-24
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-15
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-12
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... link to log on and submit the intervention or protests. Persons unable to file electronically should... protest should file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-03
... link to log on and submit the intervention or protests. Persons unable to file electronically should... protest should file with the Federal Energy Regulatory Commission, 888 First Street, NE., Washington, DC... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-05
.... Select the eFiling link to log on and submit the intervention or protests. Persons unable to file... to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... facilitate electronic service, persons with Internet access who will eFile a document and/or be listed as a...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-24
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-13
... to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-14
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-07
.... Select the eFiling link to log on and submit the intervention or protests. Persons unable to file... to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... facilitate electronic service, persons with Internet access who will eFile a document and/or be listed as a...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-25
... to protest should file with the Federal Energy Regulatory Commission, 888 First Street, NE... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-12
... link to log on and submit the intervention or protests. Persons unable to file electronically should... protest should file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-24
... link to log on and submit the intervention or protests. Persons unable to file electronically should... protest should file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-24
... to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-15
... protest should file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-27
... to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
29 CFR 1926.1420 - Signals-radio, telephone or other electronic transmission of signals.
Code of Federal Regulations, 2011 CFR
2011-07-01
... CONSTRUCTION Cranes and Derricks in Construction § 1926.1420 Signals—radio, telephone or other electronic... must be through a dedicated channel, except: (1) Multiple cranes/derricks and one or more signal persons may share a dedicated channel for the purpose of coordinating operations. (2) Where a crane is...
76 FR 19285 - Request for Information Regarding Electronic Disclosure by Employee Benefit Plans
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
..., fiber optic and wireless networks; hardware improvements to servers and personal computers improving... electronic media. For instance, the 2009 U.S. Census Bureau Current Population Survey (Census) found that 76.... \\3\\ The Census information may be found at http://www.census.gov/population/www/socdemo/computer.html...
NASA Technical Reports Server (NTRS)
Bekey, I.
1979-01-01
Three examples are used to illustrate what is possible with large space systems: (1) personal communications using wrist telephones, (2) electronic transmission of mail, and (3) wide dissemination of educational TV. Design concepts and costs are explored and compared to alternative ground-based concepts.
21 CFR 1311.10 - Eligibility to obtain a CSOS digital certificate.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Eligibility to obtain a CSOS digital certificate... REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.10 Eligibility to obtain a CSOS digital certificate. The following persons are...
49 CFR 40.163 - How does the MRO report drug test results?
Code of Federal Regulations, 2010 CFR
2010-10-01
..., the MRO may report negative results using an electronic data file. (1) If you report negatives using an electronic data file, the report must contain, as a minimum, the information specified in... contain your name, address, and phone number, the name of any person other than you reporting the results...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-26
... following methods: Electronic Submission: Submit all electronic public comments via the Federal e-Rulemaking... comment period, may not be considered. All comments received are a part of the public record and will generally be posted for public viewing on www.regulations.gov without change. All personal identifying...
ERIC Educational Resources Information Center
Steer, David; McConnell, David; Gray, Kyle; Kortz, Karen; Liang, Xin
2009-01-01
This descriptive study investigated students' answers to geoscience conceptual questions answered using electronic personal response systems. Answer patterns were examined to evaluate the peer-instruction pedagogical approach in a large general education classroom setting. (Contains 3 figures and 2 tables.)
Cyberbullying in South African and American Schools: A Legal Comparative Study
ERIC Educational Resources Information Center
Smit, D. M.
2015-01-01
Bullying conjures up visions of the traditional schoolyard bully and the subordinate victim. However, bullying is no longer limited to in-person encounter, having come to include cyberbullying, which takes place indirectly over electronic media. In this electronic age, cyber platforms proliferate at an astonishing rate, all attracting the youth in…
The Electronic Studio and the Intranet: Network-Based Learning.
ERIC Educational Resources Information Center
Solis, Carlos R.
The Electronic Studio, developed by the Rice University (Texas) Center for Technology in Teaching and Learning (CTTL), serves a number of purposes related to the construction and development of learning projects. It is a workplace, a display area, and a repository for tools, data, multimedia, design projects, and personal papers. This paper…
Dissemination Package for Transition into Electronics (TIE) Project, October 1979-June 1980.
ERIC Educational Resources Information Center
Evergreen Valley Coll., San Jose, CA.
This dissemination package consists of a variety of advertising materials, forms, questionnaires, tests, and handouts developed as a part of the Transition into Electronics (TIE) Project. (The TIE Project was a project that developed, implemented, and evaluated a model designed to encourage persons to pursue education and training leading to…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-21
... on electronic storage media. Participants may not submit paper copies of their filings unless they... that they have a good cause for not submitting documents electronically must file an exemption request.... Participants are requested not to include personal privacy information, such as social security numbers, home...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... on electronic storage media. Participants may not submit paper copies of their filings unless they... have a good cause for not submitting documents electronically must file an exemption request, in.... Participants are requested not to include personal privacy information, such as social security numbers, home...
49 CFR 1104.1 - Address, identification, and electronic filing option.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 2 of 4” and so forth). (e) Persons filing pleadings and documents with the Board have the option of electronically filing (e-filing) certain types of pleadings and documents instead of filing paper copies. Details regarding the types of pleadings and documents eligible for e-filing, the procedures to be followed, and...
ERIC Educational Resources Information Center
Keogh, Jayne; Garvis, Susanne; Pendergast, Donna; Diamond, Pat
2012-01-01
The intensification process associated with the first year of teaching has a significant impact on beginning teachers' personal and professional lives. This paper uses a narrative approach to investigate the electronic conversations of 16 beginning teachers on a self-initiated group email site. The participants' electronic exchanges demonstrated…
Modeling Growth in Electronic Learning Environments Using a Longitudinal Random Item Response Model
ERIC Educational Resources Information Center
Kadengye, Damazo T.; Ceulemans, Eva; Van Den Noortgate, Wim
2015-01-01
In educational environments, monitoring persons' progress over time may help teachers to evaluate the effectiveness of their teaching procedures. Electronic learning environments are increasingly being used as part of formal education and resulting datasets can be used to understand and to improve the environment. This study presents…
76 FR 1559 - Guidelines for the Use of Electronic Voting Systems in Union Officer Elections
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-11
... voting. Id. However, there are still concerns regarding on-line computer security, viruses and attacks... casting votes at polling sites; electronic voting from remote site personal computers via the Internet..., Washington, DC 20210. Because of security precautions, the Department continues to experience delays in U.S...
77 FR 29689 - Receipt of Amended Complaint; Solicitation of Comments Relating to the Public Interest
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-18
... complaint entitled Certain Radio Frequency Integrated Circuits and Devices Containing Same, DN 2877; the... of the complaint can be accessed on the Commission's electronic docket (EDIS) at http://edis.usitc... viewed on the Commission's electronic docket (EDIS) at http://edis.usitc.gov . Hearing-impaired persons...
Ethical questions must be considered for electronic health records.
Spriggs, Merle; Arnold, Michael V; Pearce, Christopher M; Fry, Craig
2012-09-01
National electronic health record initiatives are in progress in many countries around the world but the debate about the ethical issues and how they are to be addressed remains overshadowed by other issues. The discourse to which all others are answerable is a technical discourse, even where matters of privacy and consent are concerned. Yet a focus on technical issues and a failure to think about ethics are cited as factors in the failure of the UK health record system. In this paper, while the prime concern is the Australian Personally Controlled Electronic Health Record (PCEHR), the discussion is relevant to and informed by the international context. The authors draw attention to ethical and conceptual issues that have implications for the success or failure of electronic health records systems. Important ethical issues to consider as Australia moves towards a PCEHR system include: issues of equity that arise in the context of personal control, who benefits and who should pay, what are the legitimate uses of PCEHRs, and how we should implement privacy. The authors identify specific questions that need addressing.
Praveen, Chandni; Dancho, Brooke A.; Kingsley, David H.; Calci, Kevin R.; Meade, Gloria K.; Mena, Kristina D.
2013-01-01
Consumption of raw oysters is an exposure route for human norovirus (NoV) and hepatitis A virus (HAV). Therefore, efficient postharvest oyster treatment technology is needed to reduce public health risks. This study evaluated the inactivation of HAV and the NoV research surrogate, murine norovirus-1 (MNV-1), in oysters (Crassostrea virginica) by electron beam (E-beam) irradiation. The reduction of potential infection risks was quantified for E-beam irradiation technology employed on raw oysters at various virus contamination levels. The E-beam dose required to reduce the MNV and HAV titer by 90% (D10 value) in whole oysters was 4.05 (standard deviations [SD], ±0.63) and 4.83 (SD, ±0.08) kGy, respectively. Microbial risk assessment suggests that if a typical serving of 12 raw oysters was contaminated with 105 PFU, a 5-kGy treatment would achieve a 12% reduction (from 4.49 out of 10 persons to 3.95 out of 10 persons) in NoV infection and a 16% reduction (from 9.21 out of 10 persons to 7.76 out of 10 persons) in HAV infections. If the serving size contained only 102 PFU of viruses, a 5-kGy treatment would achieve a 26% reduction (2.74 out of 10 persons to 2.03 out of 10 persons) of NoV and 91% reduction (2.1 out of 10 persons to 1.93 out of 100 persons) of HAV infection risks. This study shows that although E-beam processing cannot completely eliminate the risk of viral illness, infection risks can be reduced. PMID:23584781
Praveen, Chandni; Dancho, Brooke A; Kingsley, David H; Calci, Kevin R; Meade, Gloria K; Mena, Kristina D; Pillai, Suresh D
2013-06-01
Consumption of raw oysters is an exposure route for human norovirus (NoV) and hepatitis A virus (HAV). Therefore, efficient postharvest oyster treatment technology is needed to reduce public health risks. This study evaluated the inactivation of HAV and the NoV research surrogate, murine norovirus-1 (MNV-1), in oysters (Crassostrea virginica) by electron beam (E-beam) irradiation. The reduction of potential infection risks was quantified for E-beam irradiation technology employed on raw oysters at various virus contamination levels. The E-beam dose required to reduce the MNV and HAV titer by 90% (D(10) value) in whole oysters was 4.05 (standard deviations [SD], ±0.63) and 4.83 (SD, ±0.08) kGy, respectively. Microbial risk assessment suggests that if a typical serving of 12 raw oysters was contaminated with 10(5) PFU, a 5-kGy treatment would achieve a 12% reduction (from 4.49 out of 10 persons to 3.95 out of 10 persons) in NoV infection and a 16% reduction (from 9.21 out of 10 persons to 7.76 out of 10 persons) in HAV infections. If the serving size contained only 10(2) PFU of viruses, a 5-kGy treatment would achieve a 26% reduction (2.74 out of 10 persons to 2.03 out of 10 persons) of NoV and 91% reduction (2.1 out of 10 persons to 1.93 out of 100 persons) of HAV infection risks. This study shows that although E-beam processing cannot completely eliminate the risk of viral illness, infection risks can be reduced.
Forchuk, Cheryl; Reiss, Jeffrey P; O'Regan, Tony; Ethridge, Paige; Donelle, Lorie; Rudnick, Abraham
2015-10-14
Information technologies such as websites, mobile phone applications, and virtual reality programs have been shown to deliver innovative and effective treatments for mental illness. Much of the research studying electronic mental health interventions focuses on symptom reduction; however, to facilitate the implementation of electronic interventions in usual mental health care, it is also important to investigate the perceptions of clients who will be using the technologies. To this end, a qualitative analysis of focus group discussions regarding the Mental Health Engagement Network, a web-based personal health record and smartphone intervention, is presented here. Individuals living in the community with a mood or psychotic disorder (n = 394) were provided with a smartphone and access to an electronic personal health record, the Lawson SMART Record, for 12 to 18 months to manage their mental health. This study employed a delayed-implementation design and obtained both quantitative and qualitative data through individual interviews and focus group sessions. Participants had the opportunity to participate in voluntary focus group sessions at three points throughout the study to discuss their perceptions of the technologies. Qualitative data from 95 focus group participants were analysed using a thematic analysis. Four overarching themes emerged from focus group discussions: 1) Versatile functionality of the Lawson SMART Record and smartphone facilitated use; 2) Aspects of the technologies as barriers to use; 3) Use of the Mental health Engagement Network technologies resulted in perceived positive outcomes; 4) Future enhancement of the Lawson SMART Record and intervention is recommended. These qualitative data provide a valuable contribution to the understanding of how smarttechnologies can be integrated into usual mental health care. Smartphones are extremely portable andcommonplace in society. Therefore, clients can use these devices to manage and track mental health issuesin any place at almost any time without feeling stigmatized. Assessing clients' perspectives regarding the use of smart technologies in mental health care provides an invaluable addition to the current literature. Qualitative findings support the feasibility of implementing a smartphone and electronic personal health record intervention with individuals who are living in the community and experiencing a mental illness, and provide considerations for future development and implementation.
Deji, Shizuhiko; Ito, Shigeki; Ariga, Eiji; Mori, Kazuyuki; Hirota, Masahiro; Saze, Takuya; Nishizawa, Kunihide
2006-08-01
High frequency electromagnetic fields in the 120 kHz band emitted from card readers for access control systems in radiation control areas cause abnormally high and erroneous indicated dose readings on semiconductor-type electronic personal dosimeters (SEPDs). All SEPDs malfunctioned but recovered their normal performance by resetting after the exposure ceased. The minimum distances required to prevent electromagnetic interference varied from 5.0 to 38.0 cm. The electric and magnetic immunity levels ranged from 35.1 to 267.6 V m(-1) and from 1.0 to 16.6 A m(-1), respectively. Electromagnetic immunity levels of SEPDs should be strengthened from the standpoint of radiation protection.
Tenopir, Carol; King, Donald W.; Bush, Amy
2004-01-01
Objectives: The objectives are to determine how medical faculty members use scholarly journals, whether print or electronic journals are read more, whether there is a pattern among types of users, and what similarities and differences there are between the use of journals by medical faculty and faculty in other disciplines. Methods: Medical faculty of the University of Tennessee Health Science Center (UTHSC) multi-campus system were surveyed, and their responses estimated using critical incident technique to characterize the different aspects of their use of print and electronic journals. Results: Medical faculty read a great deal, especially compared to scientists. The most frequently reported principal purpose of reading is to support their primary research (30% of reading). The majority of reading comes from recently published articles, mostly from personal subscriptions. Medical faculty continue to rely on print journals (approximately 70% of readings) versus electronic journals. Age of faculty does not appear to influence the choice of print or electronic format. Medical faculty read more articles than others on average and need information digested and verified in a way to save them time. Convenience and currency are highly valued attributes. Conclusions: It can be asserted that librarians and publishers must find ways to provide the attributes of convenience and currency and match the portability of personal subscriptions in an electronic journal format for medical faculty. PMID:15098053
Use of tablet personal computers for sensitive patient-reported information.
Dupont, Alexandra; Wheeler, Jane; Herndon, James E; Coan, April; Zafar, S Yousuf; Hood, Linda; Patwardhan, Meenal; Shaw, Heather S; Lyerly, H Kim; Abernethy, Amy P
2009-01-01
Notebook-style computers (e/Tablets) are increasingly replacing paper methods for collecting patient-reported information. Discrepancies in data between these methods have been found in oncology for sexuality-related questions. A study was performed to formulate hypotheses regarding causes for discrepant responses and to analyze whether electronic data collection adds value over paper-based methods when collecting data on sensitive topics. A total of 56 breast cancer patients visiting Duke Breast Clinic (North Carolina) participated by responding to 12 subscales of 5 survey instruments in electronic (e/Tablet) format and to a paper version of 1 of these surveys, at each visit. Twenty-one participants (38%) provided dissimilar responses on paper and electronic surveys to one item of the Functional Assessment of Cancer Therapy-General (FACT-G) Social Well-Being scale that asked patients to rate their satisfaction with their current sex life. Among these 21 patients were 8 patients who answered the question in the electronic environment, and 13 patients who answered both paper and electronic versions but with different responses. Eleven patients (29%) did not respond to the item on either e/Tablet or paper; 45 patients (80%) answered it on e/Tablet; and 37 patients (66%) responded on the paper version. The e/Tablet electronic system may provide a "safer" environment than paper questionnaires for cancer patients to answer private or highly personal questions on sensitive topics such as sexuality.
Tenopir, Carol; King, Donald W; Bush, Amy
2004-04-01
The objectives are to determine how medical faculty members use scholarly journals, whether print or electronic journals are read more, whether there is a pattern among types of users, and what similarities and differences there are between the use of journals by medical faculty and faculty in other disciplines. Medical faculty of the University of Tennessee Health Science Center (UTHSC) multi-campus system were surveyed, and their responses estimated using critical incident technique to characterize the different aspects of their use of print and electronic journals. Medical faculty read a great deal, especially compared to scientists. The most frequently reported principal purpose of reading is to support their primary research (30% of reading). The majority of reading comes from recently published articles, mostly from personal subscriptions. Medical faculty continue to rely on print journals (approximately 70% of readings) versus electronic journals. Age of faculty does not appear to influence the choice of print or electronic format. Medical faculty read more articles than others on average and need information digested and verified in a way to save them time. Convenience and currency are highly valued attributes. It can be asserted that librarians and publishers must find ways to provide the attributes of convenience and currency and match the portability of personal subscriptions in an electronic journal format for medical faculty.
Electronic Feedback in College Student Drinking Prevention and Intervention
Cronce, Jessica M.; Bittinger, Joyce N.; Liu, Junny; Kilmer, Jason R.
2014-01-01
Alcohol consumption is prevalent among college students and can be associated with serious negative consequences. Several efficacious programs using one-on-one brief intervention techniques have been developed to target high-risk drinking by individual students, such as the Brief Alcohol Screening and Intervention for College Students (BASICS) (Dimeff et al. 1999). To reach a larger population (e.g., the incoming freshman class), researchers have adapted these interventions so that students can access them via the Internet or in some other electronic format. The purpose of this review is to discuss specific alcohol intervention programs that were (1) designed to be delivered remotely (e.g., via the Web or on an electronic device) without interaction with a provider and (2) were tested among college students using a randomized controlled trial design. Specific studies were drawn from earlier reviews as well as a comprehensive literature search. Although many programs have limited research support, and some findings are mixed, components that were directly translated from in-person BASICS to remote-delivery mediums (i.e., personalized feedback interventions [PFIs], personalized normative feedback [PNF] interventions), and broader programs that incorporate PFI/ PNF, show promise in reducing alcohol use and/or negative consequences. However, more research is needed and suggestions for how the field can move these interventions forward are discussed. PMID:26259000
Electronic Feedback in College Student Drinking Prevention and Intervention.
Cronce, Jessica M; Bittinger, Joyce N; Liu, Junny; Kilmer, Jason R
2014-01-01
Alcohol consumption is prevalent among college students and can be associated with serious negative consequences. Several efficacious programs using one-on-one brief intervention techniques have been developed to target high-risk drinking by individual students, such as the Brief Alcohol Screening and Intervention for College Students (BASICS) (Dimeff et al. 1999). To reach a larger population (e.g., the incoming freshman class), researchers have adapted these interventions so that students can access them via the Internet or in some other electronic format.The purpose of this review is to discuss specific alcohol intervention programs that were (1) designed to be delivered remotely (e.g., via the Web or on an electronic device) without interaction with a provider and (2) were tested among college students using a randomized controlled trial design. Specific studies were drawn from earlier reviews as well as a comprehensive literature search. Although many programs have limited research support, and some findings are mixed, components that were directly translated from in-person BASICS to remote-delivery mediums (i.e., personalized feedback interventions [PFIs], personalized normative feedback [PNF] interventions), and broader programs that incorporate PFI/ PNF, show promise in reducing alcohol use and/or negative consequences. However, more research is needed and suggestions for how the field can move these interventions forward are discussed.
Understanding health care communication preferences of veteran primary care users.
LaVela, Sherri L; Schectman, Gordon; Gering, Jeffrey; Locatelli, Sara M; Gawron, Andrew; Weaver, Frances M
2012-09-01
To assess veterans' health communication preferences (in-person, telephone, or electronic) for primary care needs and the impact of computer use on preferences. Structured patient interviews (n=448). Bivariate analyses examined preferences for primary care by 'infrequent' vs. 'regular' computer users. Only 54% were regular computer users, nearly all of whom had ever used the internet. 'Telephone' was preferred for 6 of 10 reasons (general medical questions, medication questions and refills, preventive care reminders, scheduling, and test results); although telephone was preferred by markedly fewer regular computer users. 'In-person' was preferred for new/ongoing conditions/symptoms, treatment instructions, and next care steps; these preferences were unaffected by computer use frequency. Among regular computer users, 1/3 preferred 'electronic' for preventive reminders (37%), test results (34%), and refills (32%). For most primary care needs, telephone communication was preferred, although by a greater proportion of infrequent vs. regular computer users. In-person communication was preferred for reasons that may require an exam or visual instructions. About 1/3 of regular computer users prefer electronic communication for routine needs, e.g., preventive reminders, test results, and refills. These findings can be used to plan patient-centered care that is aligned with veterans' preferred health communication methods. Published by Elsevier Ireland Ltd.
Aspects of privacy for electronic health records.
Haas, Sebastian; Wohlgemuth, Sven; Echizen, Isao; Sonehara, Noboru; Müller, Günter
2011-02-01
Patients' medical data have been originally generated and maintained by health professionals in several independent electronic health records (EHRs). Centralized electronic health records accumulate medical data of patients to improve their availability and completeness; EHRs are not tied to a single medical institution anymore. Nowadays enterprises with the capacity and knowledge to maintain this kind of databases offer the services of maintaining EHRs and adding personal health data by the patients. These enterprises get access on the patients' medical data and act as a main point for collecting and disclosing personal data to third parties, e.g. among others doctors, healthcare service providers and drug stores. Existing systems like Microsoft HealthVault and Google Health comply with data protection acts by letting the patients decide on the usage and disclosure of their data. But they fail in satisfying essential requirements to privacy. We propose a privacy-protecting information system for controlled disclosure of personal data to third parties. Firstly, patients should be able to express and enforce obligations regarding a disclosure of health data to third parties. Secondly, an organization providing EHRs should neither be able to gain access to these health data nor establish a profile about patients. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
[Personalized medicine and individual healthcare : Medical and information technology aspects].
Niederlag, W; Lemke, H U; Rienhoff, O
2010-08-01
The individualization of medicine and healthcare appears to be following a general societal trend. The terms "personalized medicine" and "personal health" are used to describe this process. Here it must be emphasized that personalized medicine is not limited to pharmacogenomics, but that the spectrum of personalized medicine is much broader. Applications range from individualized diagnostics, patient-specific pharmacological therapy, therapy with individual prostheses and implants to therapy approaches using autologous cells, and from patient model-based therapy in the operating room, electronic patient records through to the individual care of patients in their home environment with the use of technical systems and services. Although in some areas practical solutions have already been found, most applications will not be fully developed for many years to come. Medical and information technology are essential to personalized medicine and personal health, each driving the other forward.
Changes in Espionage by Americans: 1947-2007
2008-03-01
of the 11 most recent cases have involved terrorists, either as recipients of information, by persons working with accused terrorists at...recent spies have relied on computers, electronic information retrieval and storage, and the Internet. The most recent cases suggest that global...cases in which individuals began espionage between 1990 and 2007 illustrate the findings in this report. Personal Attributes Most espionage by
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-14
... intervene or to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-12
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-24
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-21
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-24
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-06
... the eFiling link to log on and submit the intervention or protests. Persons unable to file... protest should file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC... electronic service, persons with Internet access who will eFile a document and/or be listed as a contact for...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-31
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-30
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
.... Select the eFiling link to log on and submit the intervention or protests. Persons unable to file... intervene or to protest should file with the Federal Energy Regulatory Commission, 888 First Street NE... facilitate electronic service, persons with Internet access who will eFile a document and/or be listed as a...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-07
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-21
... link to log on and submit the intervention or protests. Persons unable to file electronically should... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... service, persons with Internet access who will eFile a document and/or be listed as a contact for an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-12
... file with the Federal Energy Regulatory Commission, 888 First Street NE., Washington, DC 20426, in... . To facilitate electronic service, persons with Internet access who will eFile a document and/or be...Registration link. Select the eFiling link to log on and submit the intervention or protests. Persons unable to...
ERIC Educational Resources Information Center
Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Colonna, Fabio; Buonocunto, Francesca; Sacco, Valentina; Megna, Marisa; Oliva, Doretta
2012-01-01
This study assessed microswitch-based technology to enable three post-coma adults, who had emerged from a minimally conscious state but presented motor and communication disabilities, to operate a radio device. The material involved a modified radio device, a microprocessor-based electronic control unit, a personal microswitch, and an amplified…
ERIC Educational Resources Information Center
Doumas, Diana M.; Andersen, Lorna L.
2009-01-01
The efficacy of a Web-based personalized feedback program--electronic CHECKUP TO GO (e-CHUG), aimed at reducing heavy drinking in 1st-year university students--is evaluated. Results indicated that high-risk students in the e-CHUG group reported significantly greater reductions in weekly drinking quantity, frequency of drinking to intoxication, and…
ERIC Educational Resources Information Center
Doumas, Diana M.; Kane, Christina M.; Navarro, Tabitha B.; Roman, Jennifer
2011-01-01
This study evaluated the effectiveness of a web-based personalized normative feedback program, electronic Check-Up to Go (e-CHUG), in decreasing heavy drinking among 1st-year university students. Results indicated high-risk students receiving the e-CHUG program during 1st-year orientation activities reported significantly greater reductions in…
ERIC Educational Resources Information Center
Collins, James C.
2012-01-01
Poor employment outcomes for persons with intellectual disabilities (ID) persist, despite the development of legal policies designed to enhance access to gainful employment and to promote increased community integration. Recent data suggest that only 37% of young adults with ID obtain paid employment outside of the home. Among persons with ID who…
21 CFR 1305.06 - Persons entitled to fill orders for Schedule I and II controlled substances.
Code of Federal Regulations, 2010 CFR
2010-04-01
... II controlled substances, whether on a DEA Form 222 or an electronic order, may be filled only by a person registered with DEA as a manufacturer or distributor of controlled substances listed in Schedule I... DEA to dispense the substances, or to export the substances, if he/she is discontinuing business or if...
21 CFR 1305.06 - Persons entitled to fill orders for Schedule I and II controlled substances.
Code of Federal Regulations, 2011 CFR
2011-04-01
... II controlled substances, whether on a DEA Form 222 or an electronic order, may be filled only by a person registered with DEA as a manufacturer or distributor of controlled substances listed in Schedule I... DEA to dispense the substances, or to export the substances, if he/she is discontinuing business or if...
Jones, Dixie A; Shipman, Jean P; Plaut, Daphne A; Selden, Catherine R
2010-07-01
The Medical Library Association (MLA)/National Library of Medicine (NLM) Joint Electronic Personal Health Record Task Force examined the current state of personal health records (PHRs). A working definition of PHRs was formulated, and a database was built with fields for specified PHR characteristics. PHRs were identified and listed. Each task force member was assigned a portion of the list for data gathering. Findings were recorded in the database. Of the 117 PHRs identified, 91 were viable. Almost half were standalone products. A number used national standards for nomenclature and/or record structure. Less than half were mobile device enabled. Some were publicly available, and others were offered only to enrollees of particular health plans or employees at particular institutions. A few were targeted to special health conditions. The PHR field is very dynamic. While most PHR products have some common elements, their features can vary. PHRs can link their users with librarians and information resources. MLA and NLM have taken an active role in making this connection and in encouraging librarians to assume this assistance role with PHRs.
Roentgen, Uta R; Gelderblom, Gert Jan; de Witte, Luc P
2012-01-01
To develop a suitable mobility course for the assessment of mobility performance as part of a user evaluation of Electronic Mobility Aids (EMA) aimed at obstacle detection and orientation. A review of the literature led to a list of critical factors for the assessment of mobility performance of persons who are visually impaired. Based upon that list, method, test situations, and determining elements were selected and presented to Dutch orientation and mobility experts. Due to expert advice and a pilot study, minor changes were made and the final version was used for the evaluation of two EMA by eight persons who are visually impaired. The results of the literature study are summarized in an overview of critical factors for the assessment of the mobility performance of persons who are visually impaired. Applied to the requirements of the above mentioned user evaluation a replicable indoor mobility course has been described in detail and tested. Based upon evidence from literature an indoor mobility course has been developed, which was sensitive to assess differences in mobility incidents and obstacle detection when using an EMA compared to the regular mobility aid. Experts' opinion confirmed its face and content validity.
Determinants of Taxpayers' Adoption of Electronic Filing Methods in Taiwan: An Exploratory Study
ERIC Educational Resources Information Center
Fu, Jen-Ruei; Chao, Wen-Pin; Farn, Cheng-Kiang
2004-01-01
Using the personal income tax filing as an example of e-governmental services, this paper seeks to develop an understanding of the factors that influence citizens' adoption of electronic tax-filing services based on empirical data gathered from a large-scale nationwide survey. The taxpayers' satisfaction and usage intention regarding the use of…
27 CFR 26.267 - Payment of tax by electronic fund transfer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... VIRGIN ISLANDS Procedure at Port of Entry From the Virgin Islands § 26.267 Payment of tax by electronic fund transfer. (a) Each person bringing liquors and articles into the United States from the Virgin... liquors and articles into the United States from the Virgin Islands who is required, by this section, to...
Five Ways to Hack and Cheat with Bring-Your-Own-Device Electronic Examinations
ERIC Educational Resources Information Center
Dawson, Phillip
2016-01-01
Bring-your-own-device electronic examinations (BYOD e-exams) are a relatively new type of assessment where students sit an in-person exam under invigilated conditions with their own laptop. Special software restricts student access to prohibited computer functions and files, and provides access to any resources or software the examiner approves.…
A Desire for the Personal: Student Perceptions of Electronic Feedback
ERIC Educational Resources Information Center
Budge, Kylie
2011-01-01
An earlier study conducted into tertiary student perceptions of feedback on their work revealed a mixed response to the idea of electronic feedback. This result was surprising considering the attention given to Generation Y and the preference for digital technology in their lives. This paper reports on the results of a follow-up study exploring a…
The Electronic Library: The Student/Scholar Workstation, CD-ROM and Hypertext.
ERIC Educational Resources Information Center
Triebwasser, Marc A.
Predicting that a large component of the library of the not so distant future will be an electronic network of file servers where information is stored for access by personal computer workstations in remote locations as well as the library, this paper discusses innovative computer technologies--particularly CD-ROM (Compact Disk-Read Only Memory)…
Code of Federal Regulations, 2014 CFR
2014-04-01
... standard for biometric data specifications for personal identity verification. Operating point means a... records on its servers. Audit trail means a record showing who has accessed an information technology... information on a local server or hard drive. Certificate policy means a named set of rules that sets forth the...
Code of Federal Regulations, 2011 CFR
2011-04-01
... standard for biometric data specifications for personal identity verification. Operating point means a... records on its servers. Audit trail means a record showing who has accessed an information technology... information on a local server or hard drive. Certificate policy means a named set of rules that sets forth the...
Code of Federal Regulations, 2013 CFR
2013-04-01
... standard for biometric data specifications for personal identity verification. Operating point means a... records on its servers. Audit trail means a record showing who has accessed an information technology... information on a local server or hard drive. Certificate policy means a named set of rules that sets forth the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-08
... should be submitted electronically to http:[sol][sol] www.regulations.gov , docket number USTR-2010-0008. If you are unable to submit comments using http:[sol][sol] www.regulations.gov , please contact Sandy.... Persons may submit public comments electronically to http:[sol][sol] www.regulations.gov docket number...
Engagement with Electronic Screen Media among Students with Autism Spectrum Disorders
ERIC Educational Resources Information Center
Mineo, Beth A.; Ziegler, William; Gill, Susan; Salkin, Donna
2009-01-01
This study investigated the relative engagement potential of four types of electronic screen media (ESM): animated video, video of self, video of a familiar person engaged with an immersive virtual reality (VR) game, and immersion of self in the VR game. Forty-two students with autism, varying in age and expressive communication ability, were…
ERIC Educational Resources Information Center
Richards, Rhonda J.
2012-01-01
Government initiatives called for electronic health records for each individual healthcare consumer by 2014. The purpose of the initiatives is to provide for the common exchange of clinical information between healthcare consumers, healthcare providers, third-party payers and public healthcare officials. This exchange of healthcare information…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-24
... the internet, or in some cases to mail copies on electronic storage media. Participants may not submit.... Participants who believe that they have a good cause for not submitting documents electronically must file an.... Participants are requested not to include personal privacy information, such as social security numbers, home...
17 CFR 147.9 - Requests for copies of transcripts, recordings or minutes of closed meetings.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., recordings or minutes of closed meetings. (a) Copies of a transcript transcription of an electronic recording... § 147.8(a), shall be furnished to any person at the actual cost of duplication or transcription pursuant...)(9), (d) and (e). (b) Requests for copies of transcripts, transcriptions of electronic recordings or...
17 CFR 147.9 - Requests for copies of transcripts, recordings or minutes of closed meetings.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., recordings or minutes of closed meetings. (a) Copies of a transcript transcription of an electronic recording... § 147.8(a), shall be furnished to any person at the actual cost of duplication or transcription pursuant...)(9), (d) and (e). (b) Requests for copies of transcripts, transcriptions of electronic recordings or...
A Survey of Electronic News Gathering and Television News Coverage.
ERIC Educational Resources Information Center
Stone, Vernon A.; DiCioccio, John P.
A 1977 national survey of 216 television stations that use electronic news gathering (ENG) and of 224 stations that still use only film for camera reporting showed little difference in the types of news the two kinds of operations covered, although stations using ENG shot more stories than did those still using only film. The persons making…
Heuser, John E
2014-11-01
This brief essay talks up the advantages of metal replicas for electron microscopy and explains why they are still the best way to image frozen cells in the electron microscope. Then it explains our approach to freezing, namely the Van Harreveld trick of "slamming" living cells onto a supercold block of metal sprayed with liquid helium at -269ºC, and further talks up this slamming over the alternative of high-pressure freezing, which is much trickier but enjoys greater favor at the moment. This leads me to bemoan the fact that there are not more young investigators today who want to get their hands on electron microscopes and use our approach to get the most "true to life" views of cells out of them with a minimum of hassle. Finally, it ends with a few perspectives on my own career and concludes that, personally, I'm permanently stuck with the view of the "founding fathers" that cell ultrastructure will ultimately display and explain all of cell function, or as Palade said in his Nobel lecture,electron micrographs are "irresistible and half transparent … their meaning buried under only a few years of work," and "reasonable working hypotheses are already suggested by the ultrastructural organization itself." © 2014 Heuser.
Luo, Jianjun; Tang, Wei; Fan, Feng Ru; Liu, Chaofeng; Pang, Yaokun; Cao, Guozhong; Wang, Zhong Lin
2016-08-23
Portable and wearable personal electronics and smart security systems are accelerating the development of transparent, flexible, and thin-film electronic devices. Here, we report a transparent and flexible self-charging power film (SCPF) that functions either as a power generator integrated with an energy storage unit or as a self-powered information input matrix. The SCPF possesses the capability of harvesting mechanical energy from finger motions, based on the coupling between the contact electrification and electrostatic induction effects, and meanwhile storing the generated energy. Under the fast finger sliding, the film can be charged from 0 to 2.5 V within 2094 s and discharge at 1 μA for approximately 1630 s. Furthermore, the film is able to identify personal characteristics during a sliding motion by recording the electric signals related to the person's individual bioelectricity, applied pressing force, sliding speed, and so on, which shows its potential applications in security systems in touchpad technology.
Lin, Bruce K; Edelman, Emily; McInerney, Joseph D; O'Leary, James; Edelson, Vaughn; Hughes, Kevin S; Drohan, Brian; Kyler, Penny; Lloyd-Puryear, Michele; Scott, Joan; Dolan, Siobhan M
2013-05-01
In the age of genomic medicine, family health history (FHH) remains an important tool for personalized risk assessment as it can inform approaches to disease prevention and management. In primary care, including in prenatal settings, providers recognize that FHH enables them to assess the risk for birth defects and complex conditions that not only affect the fetus health, but also the mother's. However, many providers lack the time to gather FHH or the knowledge to confidently interpret the data. Electronic tools providing clinical decision support using FHH data can aid the busy provider with data collection and interpretation. We describe the scope of conditions included in a patient-entered FHH tool that provides clinical decision support and point-of-care education to assist with patient management. This report details how we selected the conditions for which it is appropriate to use FHH as a means to promote personalized medicine in primary prenatal care.
ERIC Educational Resources Information Center
Ward, Vesta
1972-01-01
Brightly banded resisters, condensers, diodes and transistors as well as printed circuit boards were used with the objective of discovering their potential in creating objects for personal adornment. (RB)
1994-07-31
everything that is received in ESD protective packaging materials treated as ESDS? YES/NO 40.1.13 Is the use of personal hygiene products , food, drinks...Does the training explain why food, drinks, smoking, personal hygiene products or common plastics are not to be used in ESD protective work areas? YES...trays? YES/NO 40.5.13 Are drinking, eating, smoking, the use of personal hygiene products and common plastics prohibited in the ESD protected work area