Sample records for electronics reliability analysis

  1. 75 FR 5633 - Notice of Extension of Comment Period for NUREG-1921, EPRI/NRC-RES Fire Human Reliability...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-03

    ..., EPRI/NRC- RES Fire Human Reliability Analysis Guidelines, Draft Report for Comment AGENCY: Nuclear... Human Reliability Analysis Guidelines, Draft Report for Comment'' (December 11, 2009; 74 FR 65810). This... Human Reliability Analysis Guidelines'' is available electronically under ADAMS Accession Number...

  2. Flight control electronics reliability/maintenance study

    NASA Technical Reports Server (NTRS)

    Dade, W. W.; Edwards, R. H.; Katt, G. T.; Mcclellan, K. L.; Shomber, H. A.

    1977-01-01

    Collection and analysis of data are reported that concern the reliability and maintenance experience of flight control system electronics currently in use on passenger carrying jet aircraft. Two airlines B-747 airplane fleets were analyzed to assess the component reliability, system functional reliability, and achieved availability of the CAT II configuration flight control system. Also assessed were the costs generated by this system in the categories of spare equipment, schedule irregularity, and line and shop maintenance. The results indicate that although there is a marked difference in the geographic location and route pattern between the airlines studied, there is a close similarity in the reliability and the maintenance costs associated with the flight control electronics.

  3. Method of Testing and Predicting Failures of Electronic Mechanical Systems

    NASA Technical Reports Server (NTRS)

    Iverson, David L.; Patterson-Hine, Frances A.

    1996-01-01

    A method employing a knowledge base of human expertise comprising a reliability model analysis implemented for diagnostic routines is disclosed. The reliability analysis comprises digraph models that determine target events created by hardware failures human actions, and other factors affecting the system operation. The reliability analysis contains a wealth of human expertise information that is used to build automatic diagnostic routines and which provides a knowledge base that can be used to solve other artificial intelligence problems.

  4. Impact of distributed power electronics on the lifetime and reliability of PV systems: Impact of distributed power electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olalla, Carlos; Maksimovic, Dragan; Deline, Chris

    Here, this paper quantifies the impact of distributed power electronics in photovoltaic (PV) systems in terms of end-of-life energy-capture performance and reliability. The analysis is based on simulations of PV installations over system lifetime at various degradation rates. It is shown how module-level or submodule-level power converters can mitigate variations in cell degradation over time, effectively increasing the system lifespan by 5-10 years compared with the nominal 25-year lifetime. An important aspect typically overlooked when characterizing such improvements is the reliability of distributed power electronics, as power converter failures may not only diminish energy yield improvements but also adversely affectmore » the overall system operation. Failure models are developed, and power electronics reliability is taken into account in this work, in order to provide a more comprehensive view of the opportunities and limitations offered by distributed power electronics in PV systems. Lastly, it is shown how a differential power-processing approach achieves the best mismatch mitigation performance and the least susceptibility to converter faults.« less

  5. Impact of distributed power electronics on the lifetime and reliability of PV systems: Impact of distributed power electronics

    DOE PAGES

    Olalla, Carlos; Maksimovic, Dragan; Deline, Chris; ...

    2017-04-26

    Here, this paper quantifies the impact of distributed power electronics in photovoltaic (PV) systems in terms of end-of-life energy-capture performance and reliability. The analysis is based on simulations of PV installations over system lifetime at various degradation rates. It is shown how module-level or submodule-level power converters can mitigate variations in cell degradation over time, effectively increasing the system lifespan by 5-10 years compared with the nominal 25-year lifetime. An important aspect typically overlooked when characterizing such improvements is the reliability of distributed power electronics, as power converter failures may not only diminish energy yield improvements but also adversely affectmore » the overall system operation. Failure models are developed, and power electronics reliability is taken into account in this work, in order to provide a more comprehensive view of the opportunities and limitations offered by distributed power electronics in PV systems. Lastly, it is shown how a differential power-processing approach achieves the best mismatch mitigation performance and the least susceptibility to converter faults.« less

  6. Reliability Estimation of Aero-engine Based on Mixed Weibull Distribution Model

    NASA Astrophysics Data System (ADS)

    Yuan, Zhongda; Deng, Junxiang; Wang, Dawei

    2018-02-01

    Aero-engine is a complex mechanical electronic system, based on analysis of reliability of mechanical electronic system, Weibull distribution model has an irreplaceable role. Till now, only two-parameter Weibull distribution model and three-parameter Weibull distribution are widely used. Due to diversity of engine failure modes, there is a big error with single Weibull distribution model. By contrast, a variety of engine failure modes can be taken into account with mixed Weibull distribution model, so it is a good statistical analysis model. Except the concept of dynamic weight coefficient, in order to make reliability estimation result more accurately, three-parameter correlation coefficient optimization method is applied to enhance Weibull distribution model, thus precision of mixed distribution reliability model is improved greatly. All of these are advantageous to popularize Weibull distribution model in engineering applications.

  7. Characterization and Reliability of Vertical N-Type Gallium Nitride Schottky Contacts

    DTIC Science & Technology

    2016-09-01

    barrier diode SEM scanning electron microscopy SiC silicon carbide SMU source measure unit xvi THIS PAGE INTENTIONALLY LEFT BLANK xvii...arguably the Schottky barrier diode (SBD). The SBD is a fundamental component in the majority of power electronic devices; specifically, those used in...Ishizuka, and Ueno demonstrated the long-term reliability of vertical metal-GaN Schottky barrier diodes through their analysis of the degradation

  8. Soft error evaluation and vulnerability analysis in Xilinx Zynq-7010 system-on chip

    NASA Astrophysics Data System (ADS)

    Du, Xuecheng; He, Chaohui; Liu, Shuhuan; Zhang, Yao; Li, Yonghong; Xiong, Ceng; Tan, Pengkang

    2016-09-01

    Radiation-induced soft errors are an increasingly important threat to the reliability of modern electronic systems. In order to evaluate system-on chip's reliability and soft error, the fault tree analysis method was used in this work. The system fault tree was constructed based on Xilinx Zynq-7010 All Programmable SoC. Moreover, the soft error rates of different components in Zynq-7010 SoC were tested by americium-241 alpha radiation source. Furthermore, some parameters that used to evaluate the system's reliability and safety were calculated using Isograph Reliability Workbench 11.0, such as failure rate, unavailability and mean time to failure (MTTF). According to fault tree analysis for system-on chip, the critical blocks and system reliability were evaluated through the qualitative and quantitative analysis.

  9. A Validity and Reliability Study of the Basic Electronics Skills Self-Efficacy Scale (BESS)

    ERIC Educational Resources Information Center

    Korkmaz, Ö.; Korkmaz, M. K.

    2016-01-01

    The aim of this study is to improve a measurement tool to evaluate the self-efficacy of Electrical-Electronics Engineering students through their basic electronics skills. The sample group is composed of 124 Electrical-Electronics engineering students. The validity of the scale is analyzed with two different methods through factor analysis and…

  10. Failure analysis of electronic parts: Laboratory methods. [for destructive and nondestructive testing

    NASA Technical Reports Server (NTRS)

    Anstead, R. J. (Editor); Goldberg, E. (Editor)

    1975-01-01

    Failure analysis test methods are presented for use in analyzing candidate electronic parts and in improving future design reliability. Each test is classified as nondestructive, semidestructive, or destructive. The effects upon applicable part types (i.e. integrated circuit, transitor) are discussed. Methodology is given for performing the following: immersion tests, radio graphic tests, dewpoint tests, gas ambient analysis, cross sectioning, and ultraviolet examination.

  11. European Symposium on Reliability of Electron Devices, Failure Physics and Analysis (5th)

    DTIC Science & Technology

    1994-10-07

    Characterisation and Modelling WEDNESDAY 5th OCTOBER Session C Hot Carriers Session D Oxide States Session E Power Devices Workshop 2 Power Devices Session F...Medium Enterprises .......... 17 W2 Power Devices Workshop "Reliability of Power Semiconductors for Traction Applications...New Mexico, USA Sandia National Laboratories, Albuquerque, New Mexico, USA SESSION E Power Devices El Reliability Issues in New Technology

  12. Computer calculation of device, circuit, equipment, and system reliability.

    NASA Technical Reports Server (NTRS)

    Crosby, D. R.

    1972-01-01

    A grouping into four classes is proposed for all reliability computations that are related to electronic equipment. Examples are presented of reliability computations in three of these four classes. Each of the three specific reliability tasks described was originally undertaken to satisfy an engineering need for reliability data. The form and interpretation of the print-out of the specific reliability computations is presented. The justification for the costs of these computations is indicated. The skills of the personnel used to conduct the analysis, the interfaces between the personnel, and the timing of the projects is discussed.

  13. Thermo-Mechanical Analysis for John Deere Electronics Solutions | Advanced

    Science.gov Websites

    impacts of alternative manufacturing processes Die, package, and interface material analysis for power module reliability Manufacturing process impacts versus thermal cycling impacts on power module

  14. Superior model for fault tolerance computation in designing nano-sized circuit systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, N. S. S., E-mail: narinderjit@petronas.com.my; Muthuvalu, M. S., E-mail: msmuthuvalu@gmail.com; Asirvadam, V. S., E-mail: vijanth-sagayan@petronas.com.my

    2014-10-24

    As CMOS technology scales nano-metrically, reliability turns out to be a decisive subject in the design methodology of nano-sized circuit systems. As a result, several computational approaches have been developed to compute and evaluate reliability of desired nano-electronic circuits. The process of computing reliability becomes very troublesome and time consuming as the computational complexity build ups with the desired circuit size. Therefore, being able to measure reliability instantly and superiorly is fast becoming necessary in designing modern logic integrated circuits. For this purpose, the paper firstly looks into the development of an automated reliability evaluation tool based on the generalizationmore » of Probabilistic Gate Model (PGM) and Boolean Difference-based Error Calculator (BDEC) models. The Matlab-based tool allows users to significantly speed-up the task of reliability analysis for very large number of nano-electronic circuits. Secondly, by using the developed automated tool, the paper explores into a comparative study involving reliability computation and evaluation by PGM and, BDEC models for different implementations of same functionality circuits. Based on the reliability analysis, BDEC gives exact and transparent reliability measures, but as the complexity of the same functionality circuits with respect to gate error increases, reliability measure by BDEC tends to be lower than the reliability measure by PGM. The lesser reliability measure by BDEC is well explained in this paper using distribution of different signal input patterns overtime for same functionality circuits. Simulation results conclude that the reliability measure by BDEC depends not only on faulty gates but it also depends on circuit topology, probability of input signals being one or zero and also probability of error on signal lines.« less

  15. Reliability Analysis for AFTI-F16 SRFCS Using ASSIST and SURE

    NASA Technical Reports Server (NTRS)

    Wu, N. Eva

    2001-01-01

    This paper reports the results of a study on reliability analysis of an AFTI-16 Self-Repairing Flight Control System (SRFCS) using software tools SURE (Semi-Markov Unreliability Range Evaluator and ASSIST (Abstract Semi-Markov Specification Interface to the SURE Tool). The purpose of the study is to investigate the potential utility of the software tools in the ongoing effort of the NASA Aviation Safety Program, where the class of systems must be extended beyond the originally intended serving class of electronic digital processors. The study concludes that SURE and ASSIST are applicable to reliability, analysis of flight control systems. They are especially efficient for sensitivity analysis that quantifies the dependence of system reliability on model parameters. The study also confirms an earlier finding on the dominant role of a parameter called a failure coverage. The paper will remark on issues related to the improvement of coverage and the optimization of redundancy level.

  16. Statistics-related and reliability-physics-related failure processes in electronics devices and products

    NASA Astrophysics Data System (ADS)

    Suhir, E.

    2014-05-01

    The well known and widely used experimental reliability "passport" of a mass manufactured electronic or a photonic product — the bathtub curve — reflects the combined contribution of the statistics-related and reliability-physics (physics-of-failure)-related processes. When time progresses, the first process results in a decreasing failure rate, while the second process associated with the material aging and degradation leads to an increased failure rate. An attempt has been made in this analysis to assess the level of the reliability physics-related aging process from the available bathtub curve (diagram). It is assumed that the products of interest underwent the burn-in testing and therefore the obtained bathtub curve does not contain the infant mortality portion. It has been also assumed that the two random processes in question are statistically independent, and that the failure rate of the physical process can be obtained by deducting the theoretically assessed statistical failure rate from the bathtub curve ordinates. In the carried out numerical example, the Raleigh distribution for the statistical failure rate was used, for the sake of a relatively simple illustration. The developed methodology can be used in reliability physics evaluations, when there is a need to better understand the roles of the statistics-related and reliability-physics-related irreversible random processes in reliability evaluations. The future work should include investigations on how powerful and flexible methods and approaches of the statistical mechanics can be effectively employed, in addition to reliability physics techniques, to model the operational reliability of electronic and photonic products.

  17. RADC thermal guide for reliability engineers

    NASA Astrophysics Data System (ADS)

    Morrison, G. N.; Kallis, J. M.; Strattan, L. A.; Jones, I. R.; Lena, A. L.

    1982-06-01

    This guide was developed to provide a reliability engineer, who is not proficient in thermal design and analysis techniques, with the tools for managing and evaluating the thermal design and production of electronic equipment. It defines the requirements and tasks that should be addressed in system equipment specifications and statements of work, and describes how to evaluate performance.

  18. The kinetic energy spectrum of protons produced by the dissociative ionization of H2 by electron impact

    NASA Technical Reports Server (NTRS)

    Khakoo, M. A.; Srivastava, S. K.

    1985-01-01

    The kinetic energy spectra of protons resulting from the dissociative ionization of H2 by electron impact have been measured for electron impact energies from threshold (approximately 17 eV) to 160 eV at 90 deg and 30 deg detection angles, using a crossed-beam experimental arrangement. To check reliability, two separate proton energy analysis methods have been employed, i.e., a time-of-flight proton energy analysis and an electrostatic hemispherical energy analyzer. The present results are compared with previous measurements.

  19. Parts and Components Reliability Assessment: A Cost Effective Approach

    NASA Technical Reports Server (NTRS)

    Lee, Lydia

    2009-01-01

    System reliability assessment is a methodology which incorporates reliability analyses performed at parts and components level such as Reliability Prediction, Failure Modes and Effects Analysis (FMEA) and Fault Tree Analysis (FTA) to assess risks, perform design tradeoffs, and therefore, to ensure effective productivity and/or mission success. The system reliability is used to optimize the product design to accommodate today?s mandated budget, manpower, and schedule constraints. Stand ard based reliability assessment is an effective approach consisting of reliability predictions together with other reliability analyses for electronic, electrical, and electro-mechanical (EEE) complex parts and components of large systems based on failure rate estimates published by the United States (U.S.) military or commercial standards and handbooks. Many of these standards are globally accepted and recognized. The reliability assessment is especially useful during the initial stages when the system design is still in the development and hard failure data is not yet available or manufacturers are not contractually obliged by their customers to publish the reliability estimates/predictions for their parts and components. This paper presents a methodology to assess system reliability using parts and components reliability estimates to ensure effective productivity and/or mission success in an efficient manner, low cost, and tight schedule.

  20. Reliability analysis of component-level redundant topologies for solid-state fault current limiter

    NASA Astrophysics Data System (ADS)

    Farhadi, Masoud; Abapour, Mehdi; Mohammadi-Ivatloo, Behnam

    2018-04-01

    Experience shows that semiconductor switches in power electronics systems are the most vulnerable components. One of the most common ways to solve this reliability challenge is component-level redundant design. There are four possible configurations for the redundant design in component level. This article presents a comparative reliability analysis between different component-level redundant designs for solid-state fault current limiter. The aim of the proposed analysis is to determine the more reliable component-level redundant configuration. The mean time to failure (MTTF) is used as the reliability parameter. Considering both fault types (open circuit and short circuit), the MTTFs of different configurations are calculated. It is demonstrated that more reliable configuration depends on the junction temperature of the semiconductor switches in the steady state. That junction temperature is a function of (i) ambient temperature, (ii) power loss of the semiconductor switch and (iii) thermal resistance of heat sink. Also, results' sensitivity to each parameter is investigated. The results show that in different conditions, various configurations have higher reliability. The experimental results are presented to clarify the theory and feasibility of the proposed approaches. At last, levelised costs of different configurations are analysed for a fair comparison.

  1. Optical activity and electronic absorption spectra of some simple nucleosides related to cytidine and uridine: all-valence-shell molecular orbital calculations.

    PubMed Central

    Miles, D W; Redington, P K; Miles, D L; Eyring, H

    1981-01-01

    The circular dichroism and electronic absorption of three simple model systems for cytidine and uridine have been measured to 190 nm. The molecular spectral properties (excitation wavelengths, oscillator strengths, rotational strengths, and polarization directions) and electronic transitional patterns were investigated by using wave functions of the entire nucleoside with the goal of establishing the reliability of the theoretical method. The computed electronic absorption quantities were shown to be in satisfactory agreement with experimental data. It was found that the computed optical rotatory strengths of the B2u and E1u electronic transitions and lowest observed n-pi transition are in good agreement with experimental values. Electronic transitions were characterized by their electronic transitional patterns derived from population analysis of the transition density matrix. The theoretical rotational strengths associated with the B2u and E1u transitions stabilize after the use of just a few singly excited configurations in the configuration interaction basis and, hypothetically, are more reliable as indicators of conformation in pyrimidine nucleosides related to cytidine. PMID:6950393

  2. Analysis of Co-Tunneling Current in Fullerene Single-Electron Transistor

    NASA Astrophysics Data System (ADS)

    KhademHosseini, Vahideh; Dideban, Daryoosh; Ahmadi, MohammadTaghi; Ismail, Razali

    2018-05-01

    Single-electron transistors (SETs) are nano devices which can be used in low-power electronic systems. They operate based on coulomb blockade effect. This phenomenon controls single-electron tunneling and it switches the current in SET. On the other hand, co-tunneling process increases leakage current, so it reduces main current and reliability of SET. Due to co-tunneling phenomenon, main characteristics of fullerene SET with multiple islands are modelled in this research. Its performance is compared with silicon SET and consequently, research result reports that fullerene SET has lower leakage current and higher reliability than silicon counterpart. Based on the presented model, lower co-tunneling current is achieved by selection of fullerene as SET island material which leads to smaller value of the leakage current. Moreover, island length and the number of islands can affect on co-tunneling and then they tune the current flow in SET.

  3. Analysis and design of digital output interface devices for gas turbine electronic controls

    NASA Technical Reports Server (NTRS)

    Newirth, D. M.; Koenig, E. W.

    1976-01-01

    A trade study was performed on twenty-one digital output interface schemes for gas turbine electronic controls to select the most promising scheme based on criteria of reliability, performance, cost, and sampling requirements. The most promising scheme, a digital effector with optical feedback of the fuel metering valve position, was designed.

  4. Reliability of muscle strength assessment in chronic post-stroke hemiparesis: a systematic review and meta-analysis.

    PubMed

    Rabelo, Michelle; Nunes, Guilherme S; da Costa Amante, Natália Menezes; de Noronha, Marcos; Fachin-Martins, Emerson

    2016-02-01

    Muscle weakness is the main cause of motor impairment among stroke survivors and is associated with reduced peak muscle torque. To systematically investigate and organize the evidence of the reliability of muscle strength evaluation measures in post-stroke survivors with chronic hemiparesis. Two assessors independently searched four electronic databases in January 2014 (Medline, Scielo, CINAHL, Embase). Inclusion criteria comprised studies on reliability on muscle strength assessment in adult post-stroke patients with chronic hemiparesis. We extracted outcomes from included studies about reliability data, measured by intraclass correlation coefficient (ICC) and/or similar. The meta-analyses were conducted only with isokinetic data. Of 450 articles, eight articles were included for this review. After quality analysis, two studies were considered of high quality. Five different joints were analyzed within the included studies (knee, hip, ankle, shoulder, and elbow). Their reliability results varying from low to very high reliability (ICCs from 0.48 to 0.99). Results of meta-analysis for knee extension varying from high to very high reliability (pooled ICCs from 0.89 to 0.97), for knee flexion varying from high to very high reliability (pooled ICCs from 0.84 to 0.91) and for ankle plantar flexion showed high reliability (pooled ICC = 0.85). Objective muscle strength assessment can be reliably used in lower and upper extremities in post-stroke patients with chronic hemiparesis.

  5. Preliminary study, analysis and design for a power switch for digital engine actuators

    NASA Technical Reports Server (NTRS)

    Beattie, E. C.; Zickwolf, H. C., Jr.

    1979-01-01

    Innovative control configurations using high temperature switches to operate actuator driving solenoids were studied. The impact on engine control system life cycle costs and reliability of electronic control and (ECU) heat dissipation due to power conditioning and interface drivers were addressed. Various power supply and actuation schemes were investigated, including optical signal transmission and electronics on the actuator, engine driven alternator, and inside the ECU. The use of a switching shunt power conditioner results in the most significant decrease in heat dissipation within the ECU. No overall control system reliability improvement is projected by the use of remote high temperature switches for solenoid drivers.

  6. Kinematics of mechanical and adhesional micromanipulation under a scanning electron microscope

    NASA Astrophysics Data System (ADS)

    Saito, Shigeki; Miyazaki, Hideki T.; Sato, Tomomasa; Takahashi, Kunio

    2002-11-01

    In this paper, the kinematics of mechanical and adhesional micromanipulation using a needle-shaped tool under a scanning electron microscope is analyzed. A mode diagram is derived to indicate the possible micro-object behavior for the specified operational conditions. Based on the diagram, a reasonable method for pick and place operation is proposed. The keys to successful analysis are to introduce adhesional and rolling-resistance factors into the kinematic system consisting of a sphere, a needle-shaped tool, and a substrate, and to consider the time dependence of these factors due to the electron-beam (EB) irradiation. Adhesional force and the lower limit of maximum rolling resistance are evaluated quantitatively in theoretical and experimental ways. This analysis shows that it is possible to control the fracture of either the tool-sphere or substrate-sphere interface of the system selectively by the tool-loading angle and that such a selective fracture of the interfaces enables reliable pick or place operation even under EB irradiation. Although the conventional micromanipulation was not repeatable because the technique was based on an empirically effective method, this analysis should provide us with a guideline to reliable micromanipulation.

  7. A Survey of Electronics Obsolescence and Reliability

    DTIC Science & Technology

    2010-07-01

    properties but there are many minor and major variations (e.g. curing schedule) affecting their usage in packaging processes and in reworking. Curing...within them. Electronic obsolescence is increasingly associated with physical characteristics that reduce component and system reliability, both in usage ...semiconductor technologies and of electronic systems, both in usage and in storage. By design, electronics technologies include few reliability margins

  8. Fine needle aspiration (FNA) of synovial sarcoma--a comparative histological-cytological study of 15 cases, including immunohistochemical, electron microscopic and cytogenetic examination and DNA-ploidy analysis.

    PubMed

    Akerman, M; Willén, H; Carlén, B; Mandahl, N; Mertens, F

    1996-06-01

    A retrospective study of 25 FNAs (11 aspirates from primary tumours and 14 from recurrencies and metastases) from 15 synovial sarcomas was performed. The cytological findings were correlated with the histopathology and the value of immunohistochemical and electron microscopic examination as well as DNA-ploidy and cytogenetic analysis for diagnosis were assessed. A reproducible cellular pattern with a reliable diagnosis of spindle cell sarcoma was possible provided that the aspirates were cell rich. However, a true biphasic pattern indicative of synovial sarcoma was only seen in one of the 25 specimens. Electron microscopic examination of the aspirates was a valuable adjunctive diagnostic method, whereas immunocytochemistry and DNA-ploidy analysis were not. Immunohistochemical, electron microscopic and cytogenetic analysis were all valuable ancillary methods when performed on surgical specimens. Malignant haemangiopericytoma and fibrosarcoma were the most important differential diagnoses in the FNA specimens.

  9. Communication: Electron ionization of DNA bases.

    PubMed

    Rahman, M A; Krishnakumar, E

    2016-04-28

    No reliable experimental data exist for the partial and total electron ionization cross sections for DNA bases, which are very crucial for modeling radiation damage in genetic material of living cell. We have measured a complete set of absolute partial electron ionization cross sections up to 500 eV for DNA bases for the first time by using the relative flow technique. These partial cross sections are summed to obtain total ion cross sections for all the four bases and are compared with the existing theoretical calculations and the only set of measured absolute cross sections. Our measurements clearly resolve the existing discrepancy between the theoretical and experimental results, thereby providing for the first time reliable numbers for partial and total ion cross sections for these molecules. The results on fragmentation analysis of adenine supports the theory of its formation in space.

  10. Electronic device for endosurgical skills training (EDEST): study of reliability.

    PubMed

    Pagador, J B; Uson, J; Sánchez, M A; Moyano, J L; Moreno, J; Bustos, P; Mateos, J; Sánchez-Margallo, F M

    2011-05-01

    Minimally Invasive Surgery procedures are commonly used in many surgical practices, but surgeons need specific training models and devices due to its difficulty and complexity. In this paper, an innovative electronic device for endosurgical skills training (EDEST) is presented. A study on reliability for this device was performed. Different electronic components were used to compose this new training device. The EDEST was focused on two basic laparoscopic tasks: triangulation and coordination manoeuvres. A configuration and statistical software was developed to complement the functionality of the device. A calibration method was used to assure the proper work of the device. A total of 35 subjects (8 experts and 27 novices) were used to check the reliability of the system using the MTBF analysis. Configuration values for triangulation and coordination exercises were calculated as 0.5 s limit threshold and 800-11,000 lux range of light intensity, respectively. Zero errors in 1,050 executions (0%) for triangulation and 21 errors in 5,670 executions (0.37%) for coordination were obtained. A MTBF of 2.97 h was obtained. The results show that the reliability of the EDEST device is acceptable when used under previously defined light conditions. These results along with previous work could demonstrate that the EDEST device can help surgeons during first training stages.

  11. Enabling More than Moore: Accelerated Reliability Testing and Risk Analysis for Advanced Electronics Packaging

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza; Evans, John W.

    2014-01-01

    For five decades, the semiconductor industry has distinguished itself by the rapid pace of improvement in miniaturization of electronics products-Moore's Law. Now, scaling hits a brick wall, a paradigm shift. The industry roadmaps recognized the scaling limitation and project that packaging technologies will meet further miniaturization needs or ak.a "More than Moore". This paper presents packaging technology trends and accelerated reliability testing methods currently being practiced. Then, it presents industry status on key advanced electronic packages, factors affecting accelerated solder joint reliability of area array packages, and IPC/JEDEC/Mil specifications for characterizations of assemblies under accelerated thermal and mechanical loading. Finally, it presents an examples demonstrating how Accelerated Testing and Analysis have been effectively employed in the development of complex spacecraft thereby reducing risk. Quantitative assessments necessarily involve the mathematics of probability and statistics. In addition, accelerated tests need to be designed which consider the desired risk posture and schedule for particular project. Such assessments relieve risks without imposing additional costs. and constraints that are not value added for a particular mission. Furthermore, in the course of development of complex systems, variances and defects will inevitably present themselves and require a decision concerning their disposition, necessitating quantitative assessments. In summary, this paper presents a comprehensive view point, from technology to systems, including the benefits and impact of accelerated testing in offsetting risk.

  12. Thermal Management and Packaging Reliability (Text Version) |

    Science.gov Websites

    Transportation Research | NREL Thermal Management and Packaging Reliability (Text Version ) Thermal Management and Packaging Reliability (Text Version) Learn how NREL's thermal management and ;Boosting Thermal Management & Reliability of Vehicle Power Electronics." Better power electronics

  13. Dynamic footprint measurement collection technique and intrarater reliability: ink mat, paper pedography, and electronic pedography.

    PubMed

    Fascione, Jeanna M; Crews, Ryan T; Wrobel, James S

    2012-01-01

    Identifying the variability of footprint measurement collection techniques and the reliability of footprint measurements would assist with appropriate clinical foot posture appraisal. We sought to identify relationships between these measures in a healthy population. On 30 healthy participants, midgait dynamic footprint measurements were collected using an ink mat, paper pedography, and electronic pedography. The footprints were then digitized, and the following footprint indices were calculated with photo digital planimetry software: footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index. Differences between techniques were identified with repeated-measures analysis of variance with post hoc test of Scheffe. In addition, to assess practical similarities between the different methods, intraclass correlation coefficients (ICCs) were calculated. To assess intrarater reliability, footprint indices were calculated twice on 10 randomly selected ink mat footprint measurements, and the ICC was calculated. Dynamic footprint measurements collected with an ink mat significantly differed from those collected with paper pedography (ICC, 0.85-0.96) and electronic pedography (ICC, 0.29-0.79), regardless of the practical similarities noted with ICC values (P = .00). Intrarater reliability for dynamic ink mat footprint measurements was high for the footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index (ICC, 0.74-0.99). Footprint measurements collected with various techniques demonstrate differences. Interchangeable use of exact values without adjustment is not advised. Intrarater reliability of a single method (ink mat) was found to be high.

  14. Power Electronics Packaging Reliability | Transportation Research | NREL

    Science.gov Websites

    interface materials, are a key enabling technology for compact, lightweight, low-cost, and reliable power , reliability, and cost. High-temperature bonded interface materials are an important facilitating technology for compact, lightweight, low-cost, reliable power electronics packaging that fully utilizes the

  15. Communication: Electron ionization of DNA bases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahman, M. A.; Krishnakumar, E., E-mail: ekkumar@tifr.res.in

    2016-04-28

    No reliable experimental data exist for the partial and total electron ionization cross sections for DNA bases, which are very crucial for modeling radiation damage in genetic material of living cell. We have measured a complete set of absolute partial electron ionization cross sections up to 500 eV for DNA bases for the first time by using the relative flow technique. These partial cross sections are summed to obtain total ion cross sections for all the four bases and are compared with the existing theoretical calculations and the only set of measured absolute cross sections. Our measurements clearly resolve themore » existing discrepancy between the theoretical and experimental results, thereby providing for the first time reliable numbers for partial and total ion cross sections for these molecules. The results on fragmentation analysis of adenine supports the theory of its formation in space.« less

  16. Advances in Flexible Hybrid Electronics Reliability

    DTIC Science & Technology

    2017-03-01

    Advances in Flexible Hybrid Electronics Reliability Douglas R. Hackler, Richard L. Chaney, Brian N. Meek, Darrell E. Leber, Seth D. Leija, Kelly J...www.americansemi.com Abstract: Flexible Hybrid Electronics combine the best characteristics of printed electronics and silicon ICs to create high performance...presented for flexible hybrid electronics systems. Keywords: FleX; flexible; flexible hybrid electronics ; FHE; Silicon-on-Polymer Introduction

  17. Relating design and environmental variables to reliability

    NASA Astrophysics Data System (ADS)

    Kolarik, William J.; Landers, Thomas L.

    The combination of space application and nuclear power source demands high reliability hardware. The possibilities of failure, either an inability to provide power or a catastrophic accident, must be minimized. Nuclear power experiences on the ground have led to highly sophisticated probabilistic risk assessment procedures, most of which require quantitative information to adequately assess such risks. In the area of hardware risk analysis, reliability information plays a key role. One of the lessons learned from the Three Mile Island experience is that thorough analyses of critical components are essential. Nuclear grade equipment shows some reliability advantages over commercial. However, no statistically significant difference has been found. A recent study pertaining to spacecraft electronics reliability, examined some 2500 malfunctions on more than 300 aircraft. The study classified the equipment failures into seven general categories. Design deficiencies and lack of environmental protection accounted for about half of all failures. Within each class, limited reliability modeling was performed using a Weibull failure model.

  18. Correlative light-electron fractography for fatigue striations characterization in metallic alloys.

    PubMed

    Hein, Luis Rogerio de Oliveira; de Oliveira, José Alberto; de Campos, Kamila Amato

    2013-09-01

    The correlative light-electron fractography technique combines correlative microscopy concepts to the extended depth-from-focus reconstruction method, associating the reliable topographic information of 3-D maps from light microscopy ordered Z-stacks to the finest lateral resolution and large focus depth from scanning electron microscopy. Fatigue striations spacing analysis can be precisely measured, by correcting the mean surface tilting with the knowledge of local elevation data from elevation maps. This new technique aims to improve the accuracy of quantitative fractography in fatigue fracture investigations. Copyright © 2013 Wiley Periodicals, Inc.

  19. Comparative Analysis of NOAA REFM and SNB3GEO Tools for the Forecast of the Fluxes of High-Energy Electrons at GEO

    NASA Technical Reports Server (NTRS)

    Balikhin, M. A.; Rodriguez, J. V.; Boynton, R. J.; Walker, S. N.; Aryan, Homayon; Sibeck, D. G.; Billings, S. A.

    2016-01-01

    Reliable forecasts of relativistic electrons at geostationary orbit (GEO) are important for the mitigation of their hazardous effects on spacecraft at GEO. For a number of years the Space Weather Prediction Center at NOAA has provided advanced online forecasts of the fluence of electrons with energy >2 MeV at GEO using the Relativistic Electron Forecast Model (REFM). The REFM forecasts are based on real-time solar wind speed observations at L1. The high reliability of this forecasting tool serves as a benchmark for the assessment of other forecasting tools. Since 2012 the Sheffield SNB3GEO model has been operating online, providing a 24 h ahead forecast of the same fluxes. In addition to solar wind speed, the SNB3GEO forecasts use solar wind density and interplanetary magnetic field B(sub z) observations at L1. The period of joint operation of both of these forecasts has been used to compare their accuracy. Daily averaged measurements of electron fluxes by GOES 13 have been used to estimate the prediction efficiency of both forecasting tools. To assess the reliability of both models to forecast infrequent events of very high fluxes, the Heidke skill score was employed. The results obtained indicate that SNB3GEO provides a more accurate 1 day ahead forecast when compared to REFM. It is shown that the correction methodology utilized by REFM potentially can improve the SNB3GEO forecast.

  20. Comparative analysis of NOAA REFM and SNB3GEO tools for the forecast of the fluxes of high-energy electrons at GEO.

    PubMed

    Balikhin, M A; Rodriguez, J V; Boynton, R J; Walker, S N; Aryan, H; Sibeck, D G; Billings, S A

    2016-01-01

    Reliable forecasts of relativistic electrons at geostationary orbit (GEO) are important for the mitigation of their hazardous effects on spacecraft at GEO. For a number of years the Space Weather Prediction Center at NOAA has provided advanced online forecasts of the fluence of electrons with energy >2 MeV at GEO using the Relativistic Electron Forecast Model (REFM). The REFM forecasts are based on real-time solar wind speed observations at L1. The high reliability of this forecasting tool serves as a benchmark for the assessment of other forecasting tools. Since 2012 the Sheffield SNB 3 GEO model has been operating online, providing a 24 h ahead forecast of the same fluxes. In addition to solar wind speed, the SNB 3 GEO forecasts use solar wind density and interplanetary magnetic field B z observations at L1.The period of joint operation of both of these forecasts has been used to compare their accuracy. Daily averaged measurements of electron fluxes by GOES 13 have been used to estimate the prediction efficiency of both forecasting tools. To assess the reliability of both models to forecast infrequent events of very high fluxes, the Heidke skill score was employed. The results obtained indicate that SNB 3 GEO provides a more accurate 1 day ahead forecast when compared to REFM. It is shown that the correction methodology utilized by REFM potentially can improve the SNB 3 GEO forecast.

  1. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devoto, D.

    2014-11-01

    The thermal performance and reliability of sintered-silver is being evaluated for power electronics packaging applications. This will be experimentally accomplished by the synthesis of large-area bonded interfaces between metalized substrates that will be subsequently subjected to thermal cycles. A finite element model of crack initiation and propagation in these bonded interfaces will allow for the interpretation of degradation rates by a crack-velocity (V)-stress intensity factor (K) analysis. The experiment is outlined, and the modeling approach is discussed.

  2. Storage Reliability of Missile Materiel Program. Storage Reliability Analysis Summary Report. Volume 1. Electrical and Electronic Devices

    DTIC Science & Technology

    1976-05-01

    since the platinum silicide and titanium metals also offer very low mobility to the alkaline ions, the BLSJ . is inert to sodium . Inversion and...gettering agents for sodium ions, thus making the cont&-nination far less mobile. The stability of the structural and electrical properties of the oxide...to be an effective barrier to sodium migration. In Beam Lead Sealed ,unction (BLSJ) devices, the silicon nitride seals the devices from sodium and

  3. Storage Reliability of Missile Materiel Program. Storage Reliability Analysis Summary Report. Volume 1. Electrical and Electronic Devices

    DTIC Science & Technology

    1978-01-01

    silicon nitride seals the devices from sodium and since the platinum silicide and titanium metals also offer very low mobility to the alkaline ions, the...of bipolar devices. These materials act as gettering agents for sodium ions, thus making the contamination far less mobile. The stability of the...parameter instability. Silicon nitride has been shown to be an effective barrier to sodium migration. In Beam Lead Sealed Junction (BLSJ) devices, the

  4. Reliability assessment of multiple quantum well avalanche photodiodes

    NASA Technical Reports Server (NTRS)

    Yun, Ilgu; Menkara, Hicham M.; Wang, Yang; Oguzman, Isamil H.; Kolnik, Jan; Brennan, Kevin F.; May, Gray S.; Wagner, Brent K.; Summers, Christopher J.

    1995-01-01

    The reliability of doped-barrier AlGaAs/GsAs multi-quantum well avalanche photodiodes fabricated by molecular beam epitaxy is investigated via accelerated life tests. Dark current and breakdown voltage were the parameters monitored. The activation energy of the degradation mechanism and median device lifetime were determined. Device failure probability as a function of time was computed using the lognormal model. Analysis using the electron beam induced current method revealed the degradation to be caused by ionic impurities or contamination in the passivation layer.

  5. Electronics reliability and measurement technology

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph S. (Editor)

    1987-01-01

    A summary is presented of the Electronics Reliability and Measurement Technology Workshop. The meeting examined the U.S. electronics industry with particular focus on reliability and state-of-the-art technology. A general consensus of the approximately 75 attendees was that "the U.S. electronics industries are facing a crisis that may threaten their existence". The workshop had specific objectives to discuss mechanisms to improve areas such as reliability, yield, and performance while reducing failure rates, delivery times, and cost. The findings of the workshop addressed various aspects of the industry from wafers to parts to assemblies. Key problem areas that were singled out for attention are identified, and action items necessary to accomplish their resolution are recommended.

  6. Stress Intensity of Delamination in a Sintered-Silver Interconnection: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVoto, D. J.; Paret, P. P.; Wereszczak, A. A.

    2014-08-01

    In automotive power electronics packages, conventional thermal interface materials such as greases, gels, and phase-change materials pose bottlenecks to heat removal and are also associated with reliability concerns. The industry trend is toward high thermal performance bonded interfaces for large-area attachments. However, because of coefficient of thermal expansion mismatches between materials/layers and resultant thermomechanical stresses, adhesive and cohesive fractures could occur, posing a reliability problem. These defects manifest themselves in increased thermal resistance. This research aims to investigate and improve the thermal performance and reliability of sintered-silver for power electronics packaging applications. This has been experimentally accomplished by the synthesismore » of large-area bonded interfaces between metalized substrates and copper base plates that have subsequently been subjected to thermal cycles. A finite element model of crack initiation and propagation in these bonded interfaces will allow for the interpretation of degradation rates by a crack-velocity (V)-stress intensity factor (K) analysis. A description of the experiment and the modeling approach are discussed.« less

  7. Reliability Issues and Solutions in Flexible Electronics Under Mechanical Fatigue

    NASA Astrophysics Data System (ADS)

    Yi, Seol-Min; Choi, In-Suk; Kim, Byoung-Joon; Joo, Young-Chang

    2018-07-01

    Flexible devices are of significant interest due to their potential expansion of the application of smart devices into various fields, such as energy harvesting, biological applications and consumer electronics. Due to the mechanically dynamic operations of flexible electronics, their mechanical reliability must be thoroughly investigated to understand their failure mechanisms and lifetimes. Reliability issue caused by bending fatigue, one of the typical operational limitations of flexible electronics, has been studied using various test methodologies; however, electromechanical evaluations which are essential to assess the reliability of electronic devices for flexible applications had not been investigated because the testing method was not established. By employing the in situ bending fatigue test, we has studied the failure mechanism for various conditions and parameters, such as bending strain, fatigue area, film thickness, and lateral dimensions. Moreover, various methods for improving the bending reliability have been developed based on the failure mechanism. Nanostructures such as holes, pores, wires and composites of nanoparticles and nanotubes have been suggested for better reliability. Flexible devices were also investigated to find the potential failures initiated by complex structures under bending fatigue strain. In this review, the recent advances in test methodology, mechanism studies, and practical applications are introduced. Additionally, perspectives including the future advance to stretchable electronics are discussed based on the current achievements in research.

  8. Reliability Issues and Solutions in Flexible Electronics Under Mechanical Fatigue

    NASA Astrophysics Data System (ADS)

    Yi, Seol-Min; Choi, In-Suk; Kim, Byoung-Joon; Joo, Young-Chang

    2018-03-01

    Flexible devices are of significant interest due to their potential expansion of the application of smart devices into various fields, such as energy harvesting, biological applications and consumer electronics. Due to the mechanically dynamic operations of flexible electronics, their mechanical reliability must be thoroughly investigated to understand their failure mechanisms and lifetimes. Reliability issue caused by bending fatigue, one of the typical operational limitations of flexible electronics, has been studied using various test methodologies; however, electromechanical evaluations which are essential to assess the reliability of electronic devices for flexible applications had not been investigated because the testing method was not established. By employing the in situ bending fatigue test, we has studied the failure mechanism for various conditions and parameters, such as bending strain, fatigue area, film thickness, and lateral dimensions. Moreover, various methods for improving the bending reliability have been developed based on the failure mechanism. Nanostructures such as holes, pores, wires and composites of nanoparticles and nanotubes have been suggested for better reliability. Flexible devices were also investigated to find the potential failures initiated by complex structures under bending fatigue strain. In this review, the recent advances in test methodology, mechanism studies, and practical applications are introduced. Additionally, perspectives including the future advance to stretchable electronics are discussed based on the current achievements in research.

  9. Stroboscopic Imaging Interferometer for MEMS Performance Measurement

    DTIC Science & Technology

    2007-07-15

    Optical Iocusing L.aser Fiber Optics I) c 0 Mim er Collimator - C d Microcope lcam. indo Cold Objcclive Splitte FingerCCD "Mount irnro MEMS PicL zStack...Electronics and Photonics Laboratory: Microelectronics, VLSI reliability, failure analysis, solid-state device physics, compound semiconductors

  10. Deterministic Line-Shape Programming of Silicon Nanowires for Extremely Stretchable Springs and Electronics.

    PubMed

    Xue, Zhaoguo; Sun, Mei; Dong, Taige; Tang, Zhiqiang; Zhao, Yaolong; Wang, Junzhuan; Wei, Xianlong; Yu, Linwei; Chen, Qing; Xu, Jun; Shi, Yi; Chen, Kunji; Roca I Cabarrocas, Pere

    2017-12-13

    Line-shape engineering is a key strategy to endow extra stretchability to 1D silicon nanowires (SiNWs) grown with self-assembly processes. We here demonstrate a deterministic line-shape programming of in-plane SiNWs into extremely stretchable springs or arbitrary 2D patterns with the aid of indium droplets that absorb amorphous Si precursor thin film to produce ultralong c-Si NWs along programmed step edges. A reliable and faithful single run growth of c-SiNWs over turning tracks with different local curvatures has been established, while high resolution transmission electron microscopy analysis reveals a high quality monolike crystallinity in the line-shaped engineered SiNW springs. Excitingly, in situ scanning electron microscopy stretching and current-voltage characterizations also demonstrate a superelastic and robust electric transport carried by the SiNW springs even under large stretching of more than 200%. We suggest that this highly reliable line-shape programming approach holds a strong promise to extend the mature c-Si technology into the development of a new generation of high performance biofriendly and stretchable electronics.

  11. A systematic review of statistical methods used to test for reliability of medical instruments measuring continuous variables.

    PubMed

    Zaki, Rafdzah; Bulgiba, Awang; Nordin, Noorhaire; Azina Ismail, Noor

    2013-06-01

    Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice. In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. The Intra-class Correlation Coefficient (ICC) is the most popular method with 25 (60%) studies having used this method followed by the comparing means (8 or 19%). Out of 25 studies using the ICC, only 7 (28%) reported the confidence intervals and types of ICC used. Most studies (71%) also tested the agreement of instruments. This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  12. Assessing performance of an Electronic Health Record (EHR) using Cognitive Task Analysis.

    PubMed

    Saitwal, Himali; Feng, Xuan; Walji, Muhammad; Patel, Vimla; Zhang, Jiajie

    2010-07-01

    Many Electronic Health Record (EHR) systems fail to provide user-friendly interfaces due to the lack of systematic consideration of human-centered computing issues. Such interfaces can be improved to provide easy to use, easy to learn, and error-resistant EHR systems to the users. To evaluate the usability of an EHR system and suggest areas of improvement in the user interface. The user interface of the AHLTA (Armed Forces Health Longitudinal Technology Application) was analyzed using the Cognitive Task Analysis (CTA) method called GOMS (Goals, Operators, Methods, and Selection rules) and an associated technique called KLM (Keystroke Level Model). The GOMS method was used to evaluate the AHLTA user interface by classifying each step of a given task into Mental (Internal) or Physical (External) operators. This analysis was performed by two analysts independently and the inter-rater reliability was computed to verify the reliability of the GOMS method. Further evaluation was performed using KLM to estimate the execution time required to perform the given task through application of its standard set of operators. The results are based on the analysis of 14 prototypical tasks performed by AHLTA users. The results show that on average a user needs to go through 106 steps to complete a task. To perform all 14 tasks, they would spend about 22 min (independent of system response time) for data entry, of which 11 min are spent on more effortful mental operators. The inter-rater reliability analysis performed for all 14 tasks was 0.8 (kappa), indicating good reliability of the method. This paper empirically reveals and identifies the following finding related to the performance of AHLTA: (1) large number of average total steps to complete common tasks, (2) high average execution time and (3) large percentage of mental operators. The user interface can be improved by reducing (a) the total number of steps and (b) the percentage of mental effort, required for the tasks. 2010 Elsevier Ireland Ltd. All rights reserved.

  13. Estimation of reliable range of electron temperature measurements with sets of given optical bandpass filters for KSTAR Thomson scattering system based on synthetic Thomson data

    NASA Astrophysics Data System (ADS)

    Kim, K.-h.; Oh, T.-s.; Park, K.-r.; Lee, J. H.; Ghim, Y.-c.

    2017-11-01

    One factor determining the reliability of measurements of electron temperature using a Thomson scattering (TS) system is transmittance of the optical bandpass filters in polychromators. We investigate the system performance as a function of electron temperature to determine reliable range of measurements for a given set of the optical bandpass filters. We show that such a reliability, i.e., both bias and random errors, can be obtained by building a forward model of the KSTAR TS system to generate synthetic TS data with the prescribed electron temperature and density profiles. The prescribed profiles are compared with the estimated ones to quantify both bias and random errors.

  14. The Role of Phase Changes in TiO2/Pt/TiO2 Filaments

    NASA Astrophysics Data System (ADS)

    Bíró, Ferenc; Hajnal, Zoltán; Dücső, Csaba; Bársony, István

    2018-04-01

    This work analyses the role of phase changes in TiO2/Pt/TiO2 layer stacks for micro-heater application regarding their stability and reliable operation. The polycrystalline Pt layer wrapped in a TiO2 adhesion layer underwent a continuous recrystallisation in a self-heating operation causing a drift in the resistance ( R) versus temperature ( T) performance. Simultaneously, the TiO2 adhesion layer also deteriorates at high temperature by phase changes from amorphous to anatase and rutile crystallite formation, which not only influences the Pt diffusion in different migration phenomena, but also reduces the cross section of the Pt heater wire. Thorough scanning electron microscopy, energy dispersive spectroscopy, cross-sectional transmission electron microscopy (XTEM) and electron beam diffraction analysis of the structures operated at increasing temperature revealed the elemental structural processes leading to the instabilities and the accelerated degradation, resulting in rapid breakdown of the heater wire. Owing to stability and reliability criteria, the conditions for safe operation of these layer structures could be determined.

  15. 1st NASA Electronic Parts Packaging (NEPP) Program Electronic Technology Workshop (ETW)

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2010-01-01

    NEPP supports all of NASA for >20 years - 7 NASA Centers and JPL actively participate The NEPP Program focuses on the reliability aspects of electronic devices - Three prime technical areas: Parts (die), Packaging, and Radiation Alternately, reliability may be viewed as: -

  16. Is laser speckle contrast analysis (LASCA) the new kid on the block in systemic sclerosis? A systematic literature review and pilot study to evaluate reliability of LASCA to measure peripheral blood perfusion in scleroderma patients.

    PubMed

    Cutolo, Maurizio; Vanhaecke, Amber; Ruaro, Barbara; Deschepper, Ellen; Ickinger, Claudia; Melsens, Karin; Piette, Yves; Trombetta, Amelia Chiara; De Keyser, Filip; Smith, Vanessa

    2018-06-06

    A reliable tool to evaluate flow is paramount in systemic sclerosis (SSc). We describe herein on the one hand a systematic literature review on the reliability of laser speckle contrast analysis (LASCA) to measure the peripheral blood perfusion (PBP) in SSc and perform an additional pilot study, investigating the intra- and inter-rater reliability of LASCA. A systematic search was performed in 3 electronic databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. In the pilot study, 30 SSc patients and 30 healthy subjects (HS) underwent LASCA assessment. Intra-rater reliability was assessed by having a first anchor rater performing the measurements at 2 time-points and inter-rater reliability by having the anchor rater and a team of second raters performing the measurements in 15 SSc and 30 HS. The measurements were repeated with a second anchor rater in the other 15 SSc patients, as external validation. Only 1 of the 14 records of interest identified through the systematic search was included in the final analysis. In the additional pilot study: intra-class correlation coefficient (ICC) for intra-rater reliability of the first anchor rater was 0.95 in SSc and 0.93 in HS, the ICC for inter-rater reliability was 0.97 in SSc and 0.93 in HS. Intra- and inter-rater reliability of the second anchor rater was 0.78 and 0.87. The identified literature regarding the reliability of LASCA measurements reports good to excellent inter-rater agreement. This very pilot study could confirm the reliability of LASCA measurements with good to excellent inter-rater agreement and found additionally good to excellent intra-rater reliability. Furthermore, similar results were found in the external validation. Copyright © 2018. Published by Elsevier B.V.

  17. Infrared interferometer spectrometer and radiometer (IRIS) instrument for Mariner/Jupiter/Saturn 1977 (MJS'77)

    NASA Technical Reports Server (NTRS)

    Vanous, D. D.

    1974-01-01

    The development and characteristics of the infrared interferometer spectrometer and radiometer (IRIS) instrument for use with the Mariner/Jupiter/Saturn space probe. The subjects discussed are: (1) the electronic design, (2) the opto-mechanical design, (3) reliability analysis, (4) quality control, and (5) program management.

  18. Increasing Completion Rate of an M4 Emergency Medicine Student End-of-Shift Evaluation Using a Mobile Electronic Platform and Real-Time Completion.

    PubMed

    Tews, Matthew C; Treat, Robert W; Nanes, Maxwell

    2016-07-01

    Medical students on an emergency medicine rotation are traditionally evaluated at the end of each shift with paper-based forms, and data are often missing due to forms not being turned in or completed. Because students' grades depend on these evaluations, change was needed to increase form rate of return. We analyzed a new electronic evaluation form and modified completion process to determine if it would increase the completion rate without altering how faculty scored student performance. During fall 2013, 29 faculty completed paper N=339 evaluations consisting of seven competencies for 33 students. In fall 2014, an electronic evaluation form with the same competencies was designed using an electronic platform and completed N=319 times by 27 faculty using 25 students' electronic devices. Feedback checkboxes were added to facilitate collection of common comments. Data was analyzed with IBM® SPSS® 21.0 using multi-factor analysis of variance with the students' global rating (GR) as an outcome. Inter-item reliability was determined with Cronbach alpha. There was a significantly higher completion rate (p=0.001) of 98% electronic vs. 69% paper forms, lower (p=0.001) missed GR rate (1% electronic. vs 12% paper), and higher mean scores (p=0.001) for the GR with the electronic (7.0±1.1) vs. paper (6.8±1.2) form. Feedback checkboxes were completed on every form. The inter-item reliability for electronic and paper forms was each alpha=0.95. The use of a new electronic form and modified completion process for evaluating students at the end of shift demonstrated a higher faculty completion rate, a lower missed data rate, a higher global rating and consistent collection of common feedback. The use of the electronic form and the process for obtaining the information made our end-of-shift evaluation process for students more reliable and provided more accurate, up-to-date information for student feedback and when determining student grades.

  19. The Interplay of Surface Mount Solder Joint Quality and Reliability of Low Volume SMAs

    NASA Technical Reports Server (NTRS)

    Ghaffarian, R.

    1997-01-01

    Spacecraft electronics including those used at the Jet Propulsion Laboratory (JPL), demand production of highly reliable assemblies. JPL has recently completed an extensive study, funded by NASA's code Q, of the interplay between manufacturing defects and reliability of ball grid array (BGA) and surface mount electronic components.

  20. Direct visualization and in-depth physical study of metal filament formation in percolated high-κ dielectrics

    NASA Astrophysics Data System (ADS)

    Li, X.; Pey, K. L.; Bosman, M.; Liu, W. H.; Kauerauf, T.

    2010-01-01

    The migration of Ta atoms from a transistor gate electrode into the percolated high-κ (HK) gate dielectrics is directly shown using transmission electron microscopy analysis. A nanoscale metal filament that formed under high current injection is identified to be the physical defect responsible for the ultrafast transient breakdown (BD) of the metal-gate/high-κ (MG/HK) gate stacks. This highly conductive metal filament poses reliability concerns for MG/HK gate stacks as it significantly reduces the post-BD reliability margin of a transistor.

  1. Modeling Electronic-Nuclear Interactions for Excitation Energy Transfer Processes in Light-Harvesting Complexes.

    PubMed

    Lee, Mi Kyung; Coker, David F

    2016-08-18

    An accurate approach for computing intermolecular and intrachromophore contributions to spectral densities to describe the electronic-nuclear interactions relevant for modeling excitation energy transfer processes in light harvesting systems is presented. The approach is based on molecular dynamics (MD) calculations of classical correlation functions of long-range contributions to excitation energy fluctuations and a separate harmonic analysis and single-point gradient quantum calculations for electron-intrachromophore vibrational couplings. A simple model is also presented that enables detailed analysis of the shortcomings of standard MD-based excitation energy fluctuation correlation function approaches. The method introduced here avoids these problems, and its reliability is demonstrated in accurate predictions for bacteriochlorophyll molecules in the Fenna-Matthews-Olson pigment-protein complex, where excellent agreement with experimental spectral densities is found. This efficient approach can provide instantaneous spectral densities for treating the influence of fluctuations in environmental dissipation on fast electronic relaxation.

  2. An effective method to accurately calculate the phase space factors for β - β - decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neacsu, Andrei; Horoi, Mihai

    2016-01-01

    Accurate calculations of the electron phase space factors are necessary for reliable predictions of double-beta decay rates and for the analysis of the associated electron angular and energy distributions. Here, we present an effective method to calculate these phase space factors that takes into account the distorted Coulomb field of the daughter nucleus, yet it allows one to easily calculate the phase space factors with good accuracy relative to the most exact methods available in the recent literature.

  3. Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

    NASA Astrophysics Data System (ADS)

    Zhao, Jifei; Lu, Xiangyang; Zhou, Kui; Yang, Ziqin; Yang, Deyu; Luo, Xing; Tan, Weiwei; Yang, Yujia

    2016-06-01

    As an important electron source, Micro-Pulse electron Gun (MPG) which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR), Free Electron Laser (FEL). The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY) curve was introduced. The self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC) effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.

  4. Field Programmable Gate Array Reliability Analysis Guidelines for Launch Vehicle Reliability Block Diagrams

    NASA Technical Reports Server (NTRS)

    Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.

    2017-01-01

    Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.

  5. Propulsion controls

    NASA Technical Reports Server (NTRS)

    Harkney, R. D.

    1980-01-01

    Increased system requirements and functional integration with the aircraft have placed an increased demand on control system capability and reliability. To provide these at an affordable cost and weight and because of the rapid advances in electronic technology, hydromechanical systems are being phased out in favor of digital electronic systems. The transition is expected to be orderly from electronic trimming of hydromechanical controls to full authority digital electronic control. Future propulsion system controls will be highly reliable full authority digital electronic with selected component and circuit redundancy to provide the required safety and reliability. Redundancy may include a complete backup control of a different technology for single engine applications. The propulsion control will be required to communicate rapidly with the various flight and fire control avionics as part of an integrated control concept.

  6. A Content Analysis of Electronic Cigarette Portrayal in Newspapers

    PubMed Central

    Yates, Katherine; Friedman, Katherine; Slater, Michael D.; Berman, Micah; Paskett, Electra D.; Ferketich, Amy K.

    2015-01-01

    Objective To determine how electronic cigarettes (e-cigarettes) are portrayed in newspaper informative articles and opinion pieces. Methods A content analysis was conducted on 450 articles published in the United States from 1997 to mid-2014 and obtained by a Newsbank search. The articles were reliably coded for overall frame, type of article, first topic and main topics addressed. Results The article topics have changed over time and suggest significant differences between news articles and opinion pieces. Informative articles focused on e-cigarette regulation, while opinion pieces highlighted their increasing popularity and perceived health benefits. Conclusions This content analysis uncovered significant interest in e-cigarettes, particularly in their regulation. The FDA should consider public perceptions of e-cigarettes when developing regulations. PMID:26229974

  7. The reliability of the Australasian Triage Scale: a meta-analysis

    PubMed Central

    Ebrahimi, Mohsen; Heydari, Abbas; Mazlom, Reza; Mirhaghi, Amir

    2015-01-01

    BACKGROUND: Although the Australasian Triage Scale (ATS) has been developed two decades ago, its reliability has not been defined; therefore, we present a meta-analyis of the reliability of the ATS in order to reveal to what extent the ATS is reliable. DATA SOURCES: Electronic databases were searched to March 2014. The included studies were those that reported samples size, reliability coefficients, and adequate description of the ATS reliability assessment. The guidelines for reporting reliability and agreement studies (GRRAS) were used. Two reviewers independently examined abstracts and extracted data. The effect size was obtained by the z-transformation of reliability coefficients. Data were pooled with random-effects models, and meta-regression was done based on the method of moment’s estimator. RESULTS: Six studies were included in this study at last. Pooled coefficient for the ATS was substantial 0.428 (95%CI 0.340–0.509). The rate of mis-triage was less than fifty percent. The agreement upon the adult version is higher than the pediatric version. CONCLUSION: The ATS has shown an acceptable level of overall reliability in the emergency department, but it needs more development to reach an almost perfect agreement. PMID:26056538

  8. Assessment of electron propagator methods for the simulation of vibrationally-resolved valence and core photoionization spectra

    PubMed Central

    Baiardi, A.; Paoloni, L.; Barone, V.; Zakrzewski, V.G.; Ortiz, J.V.

    2017-01-01

    The analysis of photoelectron spectra is usually facilitated by quantum mechanical simulations. Due to the recent improvement of experimental techniques, the resolution of experimental spectra is rapidly increasing, and the inclusion of vibrational effects is usually mandatory to obtain a reliable reproduction of the spectra. With the aim of defining a robust computational protocol, a general time-independent formulation to compute different kinds of vibrationally-resolved electronic spectra has been generalized to support also photoelectron spectroscopy. The electronic structure data underlying the simulation are computed using different electron propagator approaches. In addition to the more standard approaches, a new and robust implementation of the second-order self-energy approximation of the electron propagator based on a transition operator reference (TOEP2) is presented. To validate our implementation, a series of molecules has been used as test cases. The result of the simulations shows that, for ultraviolet photoionization spectra, the more accurate non-diagonal approaches are needed to obtain a reliable reproduction of vertical ionization energies, but diagonal approaches are sufficient for energy gradients and pole strengths. For X-ray photoelectron spectroscopy, the TOEP2 approach, besides being more efficient, is also the most accurate in the reproduction of both vertical ionization energies and vibrationally-resolved bandshapes. PMID:28521087

  9. Vibration analysis of printed circuit boards: Effect of boundary condition

    NASA Astrophysics Data System (ADS)

    Prashanth, M. D.

    2018-04-01

    A spacecraft consists of a number of electronic packages to meet the functional requirements. An electronic package is generally an assembly of printed circuit boards placed in a mechanical housing. A number of electronic components are mounted on the printed circuit board (PCB). A spacecraft experiences various types of loads during its launch such as vibration, acoustic and shock loads. Prediction of response for printed circuit boards due to vibration loads is important for mechanical design and reliability of electronic packages. The modeling and analysis of printed circuit boards is required for accurate prediction of response due to vibration loads. The response of PCB is highly dependent on the mounting configuration of PCB. In addition, anti-vibration mounts or stiffeners are used to reduce the PCB response. Vibration analysis of printed circuit boards is carried out using finite element method. The objective of this paper is to determine the dynamic characteristics of a printed circuit board. Modeling and analysis of PCB shall be carried out to study the effect of boundary conditions on the vibration response. The modeling of stiffeners or ribs shall also be considered in detail. The analysis results shall be validated using vibration tests of PCB.

  10. Research Staff | Advanced Manufacturing Research | NREL

    Science.gov Websites

    SYSTEMS CENTER Kevin Bennion leads NREL's Thermal Sciences and Systems research task focused on thermal vehicle thermal management and vehicle systems analysis. He came to NREL from Ford Motor Company, where he focused on thermal management and reliability for power electronics and electric machines for several

  11. Analysis of Technology for Compact Coherent Lidar

    NASA Technical Reports Server (NTRS)

    Amzajerdian, Farzin

    1997-01-01

    In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.

  12. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    PubMed

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which has a higher proportion of acceptable outcomes and shorter test duration relative to other CNTs, may be a reliable option; however, future studies are needed to compare the diagnostic accuracy of these instruments.

  13. Strategy for reliable strain measurement in InAs/GaAs materials from high-resolution Z-contrast STEM images

    NASA Astrophysics Data System (ADS)

    Vatanparast, Maryam; Vullum, Per Erik; Nord, Magnus; Zuo, Jian-Min; Reenaas, Turid W.; Holmestad, Randi

    2017-09-01

    Geometric phase analysis (GPA), a fast and simple Fourier space method for strain analysis, can give useful information on accumulated strain and defect propagation in multiple layers of semiconductors, including quantum dot materials. In this work, GPA has been applied to high resolution Z-contrast scanning transmission electron microscopy (STEM) images. Strain maps determined from different g vectors of these images are compared to each other, in order to analyze and assess the GPA technique in terms of accuracy. The SmartAlign tool has been used to improve the STEM image quality getting more reliable results. Strain maps from template matching as a real space approach are compared with strain maps from GPA, and it is discussed that a real space analysis is a better approach than GPA for aberration corrected STEM images.

  14. Radiative-emission analysis in charge-exchange collisions of O6 + with argon, water, and methane

    NASA Astrophysics Data System (ADS)

    Leung, Anthony C. K.; Kirchner, Tom

    2017-04-01

    Processes of electron capture followed by Auger and radiative decay were investigated in slow ion-atom and -molecule collisions. A quantum-mechanical analysis which utilizes the basis generator method within an independent electron model was carried out for collisions of O 6 + with Ar, H2O , and CH4 at impact energies of 1.17 and 2.33 keV/amu. At these impact energies, a closure approximation in the spectral representation of the Hamiltonian for molecules was found to be necessary to yield reliable results. Total single-, double-, and triple-electron-capture cross sections obtained show good agreement with previous measurements and calculations using the classical trajectory Monte Carlo method. The corresponding emission spectra from single capture for each collision system are in satisfactory agreement with previous calculations.

  15. Multiple electron processes of He and Ne by proton impact

    NASA Astrophysics Data System (ADS)

    Terekhin, Pavel Nikolaevich; Montenegro, Pablo; Quinto, Michele; Monti, Juan; Fojon, Omar; Rivarola, Roberto

    2016-05-01

    A detailed investigation of multiple electron processes (single and multiple ionization, single capture, transfer-ionization) of He and Ne is presented for proton impact at intermediate and high collision energies. Exclusive absolute cross sections for these processes have been obtained by calculation of transition probabilities in the independent electron and independent event models as a function of impact parameter in the framework of the continuum distorted wave-eikonal initial state theory. A binomial analysis is employed to calculate exclusive probabilities. The comparison with available theoretical and experimental results shows that exclusive probabilities are needed for a reliable description of the experimental data. The developed approach can be used for obtaining the input database for modeling multiple electron processes of charged particles passing through the matter.

  16. JPL preferred parts list: Reliable electronic components

    NASA Technical Reports Server (NTRS)

    Covey, R. E.; Scott, W. R.; Hess, L. M.; Steffy, T. G.; Stott, F. R.

    1982-01-01

    The JPL Preferred Parts List was prepared to provide a basis for selection of electronic parts for JPL spacecraft programs. Supporting tests for the listed parts were designed to comply with specific spacecraft environmental requirements. The list tabulates the electronic, magnetic, and electromechanical parts applicable to all JPL electronic equipment wherein reliability is a major concern. The parts listed are revelant to equipment supplied by subcontractors as well as fabricated at the laboratory.

  17. Energy dependence of effective electron mass and laser-induced ionization of wide band-gap solids

    NASA Astrophysics Data System (ADS)

    Gruzdev, V. E.

    2008-10-01

    Most of the traditional theoretical models of laser-induced ionization were developed under the assumption of constant effective electron mass or weak dependence of the effective mass on electron energy. Those assumptions exclude from consideration all the effects resulting from significant increase of the effective mass with increasing of electron energy in real the conduction band. Promotion of electrons to the states with high effective mass can be done either via laserinduced electron oscillations or via electron-particle collisions. Increase of the effective mass during laser-material interactions can result in specific regimes of ionization. Performing a simple qualitative analysis by comparison of the constant-mass approximation vs realistic dependences of the effective mass on electron energy, we demonstrate that the traditional ionization models provide reliable estimation of the ionization rate in a very limited domain of laser intensity and wavelength. By taking into account increase of the effective mass with electron energy, we demonstrate that special regimes of high-intensity photo-ionization are possible depending on laser and material parameters. Qualitative analysis of the energy dependence of the effective mass also leads to conclusion that the avalanche ionization can be stopped by the effect of electron trapping in the states with large values of the effective mass.

  18. Online beam energy measurement of Beijing electron positron collider II linear accelerator

    NASA Astrophysics Data System (ADS)

    Wang, S.; Iqbal, M.; Liu, R.; Chi, Y.

    2016-02-01

    This paper describes online beam energy measurement of Beijing Electron Positron Collider upgraded version II linear accelerator (linac) adequately. It presents the calculation formula, gives the error analysis in detail, discusses the realization in practice, and makes some verification. The method mentioned here measures the beam energy by acquiring the horizontal beam position with three beam position monitors (BPMs), which eliminates the effect of orbit fluctuation, and is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in this paper.

  19. Online beam energy measurement of Beijing electron positron collider II linear accelerator.

    PubMed

    Wang, S; Iqbal, M; Liu, R; Chi, Y

    2016-02-01

    This paper describes online beam energy measurement of Beijing Electron Positron Collider upgraded version II linear accelerator (linac) adequately. It presents the calculation formula, gives the error analysis in detail, discusses the realization in practice, and makes some verification. The method mentioned here measures the beam energy by acquiring the horizontal beam position with three beam position monitors (BPMs), which eliminates the effect of orbit fluctuation, and is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in this paper.

  20. Advanced Self-Calibrating, Self-Repairing Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J. (Inventor); Eckhoff, Anthony J. (Inventor); Angel, Lucena R. (Inventor); Perotti, Jose M. (Inventor)

    2002-01-01

    An improved self-calibrating and self-repairing Data Acquisition System (DAS) for use in inaccessible areas, such as onboard spacecraft, and capable of autonomously performing required system health checks, failure detection. When required, self-repair is implemented utilizing a "spare parts/tool box" system. The available number of spare components primarily depends upon each component's predicted reliability which may be determined using Mean Time Between Failures (MTBF) analysis. Failing or degrading components are electronically removed and disabled to reduce power consumption, before being electronically replaced with spare components.

  1. Stitch-bond parallel-gap welding for IC circuits

    NASA Technical Reports Server (NTRS)

    Chvostal, P.; Tuttle, J.; Vanderpool, R.

    1980-01-01

    Stitch-bonded flatpacks are superior to soldered dual-in-lines where size, weight, and reliability are important. Results should interest designers of packaging for complex high-reliability electronics, such as that used in security systems, industrial process control, and vehicle electronics.

  2. NASA Electronic Parts and Packaging Program

    NASA Technical Reports Server (NTRS)

    Kayali, Sammy

    2000-01-01

    NEPP program objectives are to: (1) Access the reliability of newly available electronic parts and packaging technologies for usage on NASA projects through validations, assessments, and characterizations, and the development of test methods/tools; (2)Expedite infusion paths for advanced (emerging) electronic parts and packaging technologies by evaluations of readiness for manufacturability and project usage consideration; (3) Provide NASA projects with technology selection, application, and validation guidelines for electronic parts and packaging hardware and processes; nd (4) Retain and disseminate electronic parts and packaging quality assurance, reliability validations, tools, and availability information to the NASA community.

  3. Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Jifei; Lu, Xiangyang, E-mail: xylu@pku.edu.cn; Yang, Ziqin

    As an important electron source, Micro-Pulse electron Gun (MPG) which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR), Free Electron Laser (FEL). The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY) curve was introduced. Themore » self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC) effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.« less

  4. Electron backscattering simulation in Geant4

    NASA Astrophysics Data System (ADS)

    Dondero, Paolo; Mantero, Alfonso; Ivanchencko, Vladimir; Lotti, Simone; Mineo, Teresa; Fioretti, Valentina

    2018-06-01

    The backscattering of electrons is a key phenomenon in several physics applications which range from medical therapy to space including AREMBES, the new ESA simulation framework for radiation background effects. The importance of properly reproducing this complex interaction has grown considerably in the last years and the Geant4 Monte Carlo simulation toolkit, recently upgraded to the version 10.3, is able to comply with the AREMBES requirements in a wide energy range. In this study a validation of the electron Geant4 backscattering models is performed with respect to several experimental data. In addition a selection of the most recent validation results on the electron scattering processes is also presented. Results of our analysis show a good agreement between simulations and data from several experiments, confirming the Geant4 electron backscattering models to be robust and reliable up to a few tens of electronvolts.

  5. Simple glucose reduction route for one-step synthesis of copper nanofluids

    NASA Astrophysics Data System (ADS)

    Shenoy, U. Sandhya; Shetty, A. Nityananda

    2014-01-01

    One-step method has been employed in the synthesis of copper nanofluids. Copper nitrate is reduced by glucose in the presence of sodium lauryl sulfate. The synthesized particles are characterized by X-ray diffraction technique for the phase structure; electron diffraction X-ray analysis for chemical composition; transmission electron microscopy and field emission scanning electron microscopy for the morphology; Fourier-transform infrared spectroscopy and ultraviolet-visible spectroscopy for the analysis of ingredients of the solution. Thermal conductivity, sedimentation and rheological measurements have also been carried out. It is found that the reaction parameters have considerable effect on the size of the particle formed and rate of the reaction. The techniques confirm that the synthesized particles are copper. The reported method showed promising increase in the thermal conductivity of the base fluid and is found to be reliable, simple and cost-effective method for preparing heat transfer fluids with higher stability.

  6. Reliability of an e-PRO Tool of EORTC QLQ-C30 for Measurement of Health-Related Quality of Life in Patients With Breast Cancer: Prospective Randomized Trial.

    PubMed

    Wallwiener, Markus; Matthies, Lina; Simoes, Elisabeth; Keilmann, Lucia; Hartkopf, Andreas D; Sokolov, Alexander N; Walter, Christina B; Sickenberger, Nina; Wallwiener, Stephanie; Feisst, Manuel; Gass, Paul; Fasching, Peter A; Lux, Michael P; Wallwiener, Diethelm; Taran, Florin-Andrei; Rom, Joachim; Schneeweiss, Andreas; Graf, Joachim; Brucker, Sara Y

    2017-09-14

    Breast cancer represents the most common malignant disease in women worldwide. As currently systematic palliative treatment only has a limited effect on survival rates, the concept of health-related quality of life (HRQoL) is gaining more and more importance in the therapy setting of metastatic breast cancer. One of the major patient-reported outcomes (PROs) for measuring HRQoL in patients with breast cancer is provided by the European Organization for Research and Treatment of Cancer (EORTC). Currently, paper-based surveys still predominate, as only a few reliable and validated electronic-based questionnaires are available. Facing the possibilities associated with evolving digitalization in medicine, validation of electronic versions of well-established PRO is essential in order to contribute to comprehensive and holistic oncological care and to ensure high quality in cancer research. The aim of this study was to analyze the reliability of a tablet-based measuring application for EORTC QLQ-C30 in German language in patients with adjuvant and (curative) metastatic breast cancer. Paper- and tablet-based questionnaires were completed by a total of 106 female patients with adjuvant and metastatic breast cancer recruited as part of the e-PROCOM study. All patients were required to complete the electronic- (e-PRO) and paper-based versions of the HRQoL EORTC QLQ-C30 questionnaire. A frequency analysis was performed to determine descriptive sociodemographic characteristics. Both dimensions of reliability (parallel forms reliability [Wilcoxon test] and test of internal consistency [Spearman rho and agreement rates for single items, Pearson correlation and Kendall tau for each scale]) were analyzed. High correlations were shown for both dimensions of reliability (parallel forms reliability and internal consistency) in the patient's response behavior between paper- and electronic-based questionnaires. Regarding the test of parallel forms reliability, no significant differences were found in 27 of 30 single items and in 14 of 15 scales, whereas a statistically significant correlation in the test of consistency was found in all 30 single items and all 15 scales. The evaluated e-PRO version of the EORTC QLQ-C30 is reliable for patients with both adjuvant and metastatic breast cancer, showing a high correlation in almost all questions (and in many scales). Thus, we conclude that the validated paper-based PRO assessment and the e-PRO tool are equally valid. However, the reliability should also be analyzed in other prospective trials to ensure that usability is reliable in all patient groups. ClinicalTrials.gov NCT03132506; https://clinicaltrials.gov/ct2/show/NCT03132506 (Archived by WebCite at http://www.webcitation.org/6tRcgQuou). ©Markus Wallwiener, Lina Matthies, Elisabeth Simoes, Lucia Keilmann, Andreas D Hartkopf, Alexander N Sokolov, Christina B Walter, Nina Sickenberger, Stephanie Wallwiener, Manuel Feisst, Paul Gass, Peter A Fasching, Michael P Lux, Diethelm Wallwiener, Florin-Andrei Taran, Joachim Rom, Andreas Schneeweiss, Joachim Graf, Sara Y Brucker. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 14.09.2017.

  7. Operational and customer relationship management considerations of electronic prescribing among pharmacists.

    PubMed

    Smith, Alan D; Motley, Darlene

    2009-01-01

    Technology in healthcare environments has increasingly become a vital way to communicate vital information in a safe, reliable, precise and secure manner. Healthcare is an arena that is constantly changing and very fast paced, but adoption of electronic prescribing (e-prescribing) has been comparatively slow and painful in the USA. Medical professionals need a system to communicate medications and diagnosis, with patients' safety as the major consideration, especially with the many complexities associated with drug-interactions and allergies. Via multivariate analysis and linear regression analysis, it was found that degree of e-prescribing acceptance is highly predictable by constructs of Technological Sophistication, Operational Factors and Maturity Factors, which are very stable ease-of-use variables derived from the TAM Model by Davis (1989).

  8. Power Electronics and Electric Machines | Transportation Research | NREL

    Science.gov Websites

    -to resource for information from cutting-edge thermal management research, making wide-scale adoption battery, the motor, and other powertrain components. NREL's thermal management and reliability research is thermal management technologies to improve performance, cost, and reliability for power electronics and

  9. Quality management for space systems in ISRO

    NASA Astrophysics Data System (ADS)

    Satish, S.; Selva Raju, S.; Nanjunda Swamy, T. S.; Kulkarni, P. L.

    2009-11-01

    In a little over four decades, the Indian Space Program has carved a niche for itself with the unique application driven program oriented towards National development. The end-to-end capability approach of the space projects in the country call for innovative practices and procedures in assuring the quality and reliability of space systems. The System Reliability (SR) efforts initiated at the start of the projects continue during the entire life cycle of the project encompassing design, development, realisation, assembly, testing and integration and during launch. Even after the launch, SR groups participate in the on-orbit evaluation of transponders in communication satellites and camera systems in remote sensing satellites. SR groups play a major role in identification, evaluation and inculcating quality practices in work centres involved in the fabrication of mechanical, electronics and propulsion systems required for Indian Space Research Organization's (ISRO's) launch vehicle and spacecraft projects. Also the reliability analysis activities like prediction, assessment and demonstration as well as de-rating analysis, Failure Mode Effects and Criticality Analysis (FMECA) and worst-case analysis are carried out by SR groups during various stages of project realisation. These activities provide the basis for project management to take appropriate techno-managerial decisions to ensure that the required reliability goals are met. Extensive test facilities catering to the needs of the space program has been set up. A system for consolidating the experience and expertise gained for issue of standards called product assurance specifications to be used in all ISRO centres has also been established.

  10. Electronic versus paper-based assessment of health-related quality of life specific to HIV disease: reliability study of the PROQOL-HIV questionnaire.

    PubMed

    Duracinsky, Martin; Lalanne, Christophe; Goujard, Cécile; Herrmann, Susan; Cheung-Lung, Christian; Brosseau, Jean-Paul; Schwartz, Yannick; Chassany, Olivier

    2014-04-25

    Electronic patient-reported outcomes (PRO) provide quick and usually reliable assessments of patients' health-related quality of life (HRQL). An electronic version of the Patient-Reported Outcomes Quality of Life-human immunodeficiency virus (PROQOL-HIV) questionnaire was developed, and its face validity and reliability were assessed using standard psychometric methods. A sample of 80 French outpatients (66% male, 52/79; mean age 46.7 years, SD 10.9) were recruited. Paper-based and electronic questionnaires were completed in a randomized crossover design (2-7 day interval). Biomedical data were collected. Questionnaire version and order effects were tested on full-scale scores in a 2-way ANOVA with patients as random effects. Test-retest reliability was evaluated using Pearson and intraclass correlation coefficients (ICC, with 95% confidence interval) for each dimension. Usability testing was carried out from patients' survey reports, specifically, general satisfaction, ease of completion, quality and clarity of user interface, and motivation to participate in follow-up PROQOL-HIV electronic assessments. Questionnaire version and administration order effects (N=59 complete cases) were not significant at the 5% level, and no interaction was found between these 2 factors (P=.94). Reliability indexes were acceptable, with Pearson correlations greater than .7 and ICCs ranging from .708 to .939; scores were not statistically different between the two versions. A total of 63 (79%) complete patients' survey reports were available, and 55% of patients (30/55) reported being satisfied and interested in electronic assessment of their HRQL in clinical follow-up. Individual ratings of PROQOL-HIV user interface (85%-100% of positive responses) confirmed user interface clarity and usability. The electronic PROQOL-HIV introduces minor modifications to the original paper-based version, following International Society for Pharmacoeconomics and Outcomes Research (ISPOR) ePRO Task Force guidelines, and shows good reliability and face validity. Patients can complete the computerized PROQOL-HIV questionnaire and the scores from the paper or electronic versions share comparable accuracy and interpretation.

  11. Electronic Versus Paper-Based Assessment of Health-Related Quality of Life Specific to HIV Disease: Reliability Study of the PROQOL-HIV Questionnaire

    PubMed Central

    Lalanne, Christophe; Goujard, Cécile; Herrmann, Susan; Cheung-Lung, Christian; Brosseau, Jean-Paul; Schwartz, Yannick; Chassany, Olivier

    2014-01-01

    Background Electronic patient-reported outcomes (PRO) provide quick and usually reliable assessments of patients’ health-related quality of life (HRQL). Objective An electronic version of the Patient-Reported Outcomes Quality of Life-human immunodeficiency virus (PROQOL-HIV) questionnaire was developed, and its face validity and reliability were assessed using standard psychometric methods. Methods A sample of 80 French outpatients (66% male, 52/79; mean age 46.7 years, SD 10.9) were recruited. Paper-based and electronic questionnaires were completed in a randomized crossover design (2-7 day interval). Biomedical data were collected. Questionnaire version and order effects were tested on full-scale scores in a 2-way ANOVA with patients as random effects. Test-retest reliability was evaluated using Pearson and intraclass correlation coefficients (ICC, with 95% confidence interval) for each dimension. Usability testing was carried out from patients’ survey reports, specifically, general satisfaction, ease of completion, quality and clarity of user interface, and motivation to participate in follow-up PROQOL-HIV electronic assessments. Results Questionnaire version and administration order effects (N=59 complete cases) were not significant at the 5% level, and no interaction was found between these 2 factors (P=.94). Reliability indexes were acceptable, with Pearson correlations greater than .7 and ICCs ranging from .708 to .939; scores were not statistically different between the two versions. A total of 63 (79%) complete patients’ survey reports were available, and 55% of patients (30/55) reported being satisfied and interested in electronic assessment of their HRQL in clinical follow-up. Individual ratings of PROQOL-HIV user interface (85%-100% of positive responses) confirmed user interface clarity and usability. Conclusions The electronic PROQOL-HIV introduces minor modifications to the original paper-based version, following International Society for Pharmacoeconomics and Outcomes Research (ISPOR) ePRO Task Force guidelines, and shows good reliability and face validity. Patients can complete the computerized PROQOL-HIV questionnaire and the scores from the paper or electronic versions share comparable accuracy and interpretation. PMID:24769643

  12. Legal issues concerning electronic health information: privacy, quality, and liability.

    PubMed

    Hodge, J G; Gostin, L O; Jacobson, P D

    1999-10-20

    Personally identifiable health information about individuals and general medical information is increasingly available in electronic form in health databases and through online networks. The proliferation of electronic data within the modern health information infrastructure presents significant benefits for medical providers and patients, including enhanced patient autonomy, improved clinical treatment, advances in health research and public health surveillance, and modern security techniques. However, it also presents new legal challenges in 3 interconnected areas: privacy of identifiable health information, reliability and quality of health data, and tortbased liability. Protecting health information privacy (by giving individuals control over health data without severely restricting warranted communal uses) directly improves the quality and reliability of health data (by encouraging individual uses of health services and communal uses of data), which diminishes tort-based liabilities (by reducing instances of medical malpractice or privacy invasions through improvements in the delivery of health care services resulting in part from better quality and reliability of clinical and research data). Following an analysis of the interconnectivity of these 3 areas and discussing existing and proposed health information privacy laws, recommendations for legal reform concerning health information privacy are presented. These include (1) recognizing identifiable health information as highly sensitive, (2) providing privacy safeguards based on fair information practices, (3) empowering patients with information and rights to consent to disclosure (4) limiting disclosures of health data absent consent, (5) incorporating industry-wide security protections, (6) establishing a national data protection authority, and (7) providing a national minimal level of privacy protections.

  13. Application of a high-energy-density permanent magnet material in underwater systems

    NASA Astrophysics Data System (ADS)

    Cho, C. P.; Egan, C.; Krol, W. P.

    1996-06-01

    This paper addresses the application of high-energy-density permanent magnet (PM) technology to (1) the brushless, axial-field PM motor and (2) the integrated electric motor/pump system for under-water applications. Finite-element analysis and lumped parameter magnetic circuit analysis were used to calculate motor parameters and performance characteristics and to conduct tradeoff studies. Compact, efficient, reliable, and quiet underwater systems are attainable with the development of high-energy-density PM material, power electronic devices, and power integrated-circuit technology.

  14. Improved Temperature Diagnostic for Non-Neutral Plasmas with Single-Electron Resolution

    NASA Astrophysics Data System (ADS)

    Shanman, Sabrina; Evans, Lenny; Fajans, Joel; Hunter, Eric; Nelson, Cheyenne; Sierra, Carlos; Wurtele, Jonathan

    2016-10-01

    Plasma temperature diagnostics in a Penning-Malmberg trap are essential for reliably obtaining cold, non-neutral plasmas. We have developed a setup for detecting the initial electrons that escape from a trapped pure electron plasma as the confining electrode potential is slowly reduced. The setup minimizes external noise by using a silicon photomultiplier to capture light emitted from an MCP-amplified phosphor screen. To take advantage of this enhanced resolution, we have developed a new plasma temperature diagnostic analysis procedure which takes discrete electron arrival times as input. We have run extensive simulations comparing this new discrete algorithm to our existing exponential fitting algorithm. These simulations are used to explore the behavior of these two temperature diagnostic procedures at low N and at high electronic noise. This work was supported by the DOE DE-FG02-06ER54904, and the NSF 1500538-PHY.

  15. Hydrogen positions in single nanocrystals revealed by electron diffraction

    NASA Astrophysics Data System (ADS)

    Palatinus, L.; Brázda, P.; Boullay, P.; Perez, O.; Klementová, M.; Petit, S.; Eigner, V.; Zaarour, M.; Mintova, S.

    2017-01-01

    The localization of hydrogen atoms is an essential part of crystal structure analysis, but it is difficult because of their small scattering power. We report the direct localization of hydrogen atoms in nanocrystalline materials, achieved using the recently developed approach of dynamical refinement of precession electron diffraction tomography data. We used this method to locate hydrogen atoms in both an organic (paracetamol) and an inorganic (framework cobalt aluminophosphate) material. The results demonstrate that the technique can reliably reveal fine structural details, including the positions of hydrogen atoms in single crystals with micro- to nanosized dimensions.

  16. X-ray spectrophotometer SphinX and particle spectrometer STEP-F of the satellite experiment CORONAS-PHOTON. Preliminary results of the joint data analysis

    NASA Astrophysics Data System (ADS)

    Dudnik, O. V.; Podgorski, P.; Sylwester, J.; Gburek, S.; Kowalinski, M.; Siarkowski, M.; Plocieniak, S.; Bakala, J.

    2012-04-01

    A joint analysis is carried out of data obtained with the help of the solar X-ray SphinX spectrophotometer and the electron and proton satellite telescope STEP-F in May 2009 in the course of the scientific space experiment CORONAS-PHOTON. In order to determine the energies and particle types, in the analysis of spectrophotometer records data are used on the intensities of electrons, protons, and secondary γ-radiation, obtained by the STEP-F telescope, which was located in close proximity to the SphinX spectrophotometer. The identical reaction of both instruments is noted at the intersection of regions of the Brazilian magnetic anomaly and the Earth's radiation belts. It is shown that large area photodiodes, serving as sensors of the X-ray spectrometer, reliably record electron fluxes of low and intermediate energies, as well as fluxes of the secondary gamma radiation from construction materials of detector modules, the TESIS instrument complex, and the spacecraft itself. The dynamics of electron fluxes, recorded by the SphinX spectrophotometer in the vicinity of a weak geomagnetic storm, supplements the information about the processes of radial diffusion of electrons, which was studied using the STEP-F telescope.

  17. GaN-on-diamond electronic device reliability: Mechanical and thermo-mechanical integrity

    NASA Astrophysics Data System (ADS)

    Liu, Dong; Sun, Huarui; Pomeroy, James W.; Francis, Daniel; Faili, Firooz; Twitchen, Daniel J.; Kuball, Martin

    2015-12-01

    The mechanical and thermo-mechanical integrity of GaN-on-diamond wafers used for ultra-high power microwave electronic devices was studied using a micro-pillar based in situ mechanical testing approach combined with an optical investigation of the stress and heat transfer across interfaces. We find the GaN/diamond interface to be thermo-mechanically stable, illustrating the potential for this material for reliable GaN electronic devices.

  18. Improved model for detection of homogeneous production batches of electronic components

    NASA Astrophysics Data System (ADS)

    Kazakovtsev, L. A.; Orlov, V. I.; Stashkov, D. V.; Antamoshkin, A. N.; Masich, I. S.

    2017-10-01

    Supplying the electronic units of the complex technical systems with electronic devices of the proper quality is one of the most important problems for increasing the whole system reliability. Moreover, for reaching the highest reliability of an electronic unit, the electronic devices of the same type must have equal characteristics which assure their coherent operation. The highest homogeneity of the characteristics is reached if the electronic devices are manufactured as a single production batch. Moreover, each production batch must contain homogeneous raw materials. In this paper, we propose an improved model for detecting the homogeneous production batches of shipped lot of electronic components based on implementing the kurtosis criterion for the results of non-destructive testing performed for each lot of electronic devices used in the space industry.

  19. Quality assurance and reliability in the Japanese electronics industry

    NASA Astrophysics Data System (ADS)

    Pecht, Michael; Boulton, William R.

    1995-02-01

    Quality and reliability are two attributes required for all Japanese products, although the JTEC panel found these attributes to be secondary to customer cost requirements. While our Japanese hosts gave presentations on the challenges of technology, cost, and miniaturization, quality and reliability were infrequently the focus of our discussions. Quality and reliability were assumed to be sufficient to meet customer needs. Fujitsu's slogan, 'quality built-in, with cost and performance as prime consideration,' illustrates this point. Sony's definition of a next-generation product is 'one that is going to be half the size and half the price at the same performance of the existing one'. Quality and reliability are so integral to Japan's electronics industry that they need no new emphasis.

  20. Quality assurance and reliability in the Japanese electronics industry

    NASA Technical Reports Server (NTRS)

    Pecht, Michael; Boulton, William R.

    1995-01-01

    Quality and reliability are two attributes required for all Japanese products, although the JTEC panel found these attributes to be secondary to customer cost requirements. While our Japanese hosts gave presentations on the challenges of technology, cost, and miniaturization, quality and reliability were infrequently the focus of our discussions. Quality and reliability were assumed to be sufficient to meet customer needs. Fujitsu's slogan, 'quality built-in, with cost and performance as prime consideration,' illustrates this point. Sony's definition of a next-generation product is 'one that is going to be half the size and half the price at the same performance of the existing one'. Quality and reliability are so integral to Japan's electronics industry that they need no new emphasis.

  1. Characterization of Ultra-fine Grained and Nanocrystalline Materials Using Transmission Kikuchi Diffraction

    PubMed Central

    Proust, Gwénaëlle; Trimby, Patrick; Piazolo, Sandra; Retraint, Delphine

    2017-01-01

    One of the challenges in microstructure analysis nowadays resides in the reliable and accurate characterization of ultra-fine grained (UFG) and nanocrystalline materials. The traditional techniques associated with scanning electron microscopy (SEM), such as electron backscatter diffraction (EBSD), do not possess the required spatial resolution due to the large interaction volume between the electrons from the beam and the atoms of the material. Transmission electron microscopy (TEM) has the required spatial resolution. However, due to a lack of automation in the analysis system, the rate of data acquisition is slow which limits the area of the specimen that can be characterized. This paper presents a new characterization technique, Transmission Kikuchi Diffraction (TKD), which enables the analysis of the microstructure of UFG and nanocrystalline materials using an SEM equipped with a standard EBSD system. The spatial resolution of this technique can reach 2 nm. This technique can be applied to a large range of materials that would be difficult to analyze using traditional EBSD. After presenting the experimental set up and describing the different steps necessary to realize a TKD analysis, examples of its use on metal alloys and minerals are shown to illustrate the resolution of the technique and its flexibility in term of material to be characterized. PMID:28447998

  2. Characterization of Ultra-fine Grained and Nanocrystalline Materials Using Transmission Kikuchi Diffraction.

    PubMed

    Proust, Gwénaëlle; Trimby, Patrick; Piazolo, Sandra; Retraint, Delphine

    2017-04-01

    One of the challenges in microstructure analysis nowadays resides in the reliable and accurate characterization of ultra-fine grained (UFG) and nanocrystalline materials. The traditional techniques associated with scanning electron microscopy (SEM), such as electron backscatter diffraction (EBSD), do not possess the required spatial resolution due to the large interaction volume between the electrons from the beam and the atoms of the material. Transmission electron microscopy (TEM) has the required spatial resolution. However, due to a lack of automation in the analysis system, the rate of data acquisition is slow which limits the area of the specimen that can be characterized. This paper presents a new characterization technique, Transmission Kikuchi Diffraction (TKD), which enables the analysis of the microstructure of UFG and nanocrystalline materials using an SEM equipped with a standard EBSD system. The spatial resolution of this technique can reach 2 nm. This technique can be applied to a large range of materials that would be difficult to analyze using traditional EBSD. After presenting the experimental set up and describing the different steps necessary to realize a TKD analysis, examples of its use on metal alloys and minerals are shown to illustrate the resolution of the technique and its flexibility in term of material to be characterized.

  3. Elaboration and Validation of the Medication Prescription Safety Checklist 1

    PubMed Central

    Pires, Aline de Oliveira Meireles; Ferreira, Maria Beatriz Guimarães; do Nascimento, Kleiton Gonçalves; Felix, Márcia Marques dos Santos; Pires, Patrícia da Silva; Barbosa, Maria Helena

    2017-01-01

    ABSTRACT Objective: to elaborate and validate a checklist to identify compliance with the recommendations for the structure of medication prescriptions, based on the Protocol of the Ministry of Health and the Brazilian Health Surveillance Agency. Method: methodological research, conducted through the validation and reliability analysis process, using a sample of 27 electronic prescriptions. Results: the analyses confirmed the content validity and reliability of the tool. The content validity, obtained by expert assessment, was considered satisfactory as it covered items that represent the compliance with the recommendations regarding the structure of the medication prescriptions. The reliability, assessed through interrater agreement, was excellent (ICC=1.00) and showed perfect agreement (K=1.00). Conclusion: the Medication Prescription Safety Checklist showed to be a valid and reliable tool for the group studied. We hope that this study can contribute to the prevention of adverse events, as well as to the improvement of care quality and safety in medication use. PMID:28793128

  4. Real-time electron density measurements from Cotton-Mouton effect in JET machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brombin, M.; Electrical Engineering Department, Padova University, via Gradenigo 6-A, 35131 Padova; Boboc, A.

    Real-time density profile measurements are essential for advanced fusion tokamak operation and interferometry is a proven method for this task. Nevertheless, as a consequence of edge localized modes, pellet injections, fast density increases, or disruptions, the interferometer is subject to fringe jumps, which produce loss of the signal preventing reliable use of the measured density in a real-time feedback controller. An alternative method to measure the density is polarimetry based on the Cotton-Mouton effect, which is proportional to the line-integrated electron density. A new analysis approach has been implemented and tested to verify the reliability of the Cotton-Mouton measurements formore » a wide range of plasma parameters and to compare the density evaluated from polarimetry with that from interferometry. The density measurements based on polarimetry are going to be integrated in the real-time control system of JET since the difference with the interferometry is within one fringe for more than 90% of the cases.« less

  5. 75 FR 14386 - Interpretation of Transmission Planning Reliability Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-25

    ... created electronically using word processing software should be filed in native applications or print-to.... FERC, 564 F.3d 1342 (DC Cir. 2009). \\6\\ Mandatory Reliability Standards for the Bulk-Power System... print-to-PDF format and not in a scanned format. Commenters filing electronically do not need to make a...

  6. Reliable Assessment with CyberTutor, a Web-Based Homework Tutor.

    ERIC Educational Resources Information Center

    Pritchard, David E.; Morote, Elsa-Sofia

    This paper demonstrates that an electronic tutoring program can collect data that enables a far more reliable assessment of students' skills than a standard examination. Socratic electronic homework tutor, CyberTutor can integrate effectively instruction and assessment. CyberTutor assessment has about 62 times less variance due to random test…

  7. Reliability Prediction for Aerospace Electronics

    DTIC Science & Technology

    2015-04-20

    RESEARCH AUTHORITY 3 KIRYAT HAMADA ARIEL ISRAEL EOARD GRANT FA9550-14-1-0216 Report Date: April 2015 Final Report for 15 July 2014 to 14... Ariel , Israel Period of Performance 15 July 2014 – 14 April 2015   Abstract...AFRL-AFOSR-UK-TR-2015-0028 Reliability Prediction for Aerospace Electronics Joseph B. Bernstein ARIEL UNIVERSITY

  8. Digital interface of electronic transformers based on embedded system

    NASA Astrophysics Data System (ADS)

    Shang, Qiufeng; Qi, Yincheng

    2008-10-01

    Benefited from digital interface of electronic transformers, information sharing and system integration in substation can be realized. An embedded system-based digital output scheme of electronic transformers is proposed. The digital interface is designed with S3C44B0X 32bit RISC microprocessor as the hardware platform. The μCLinux operation system (OS) is transplanted on ARM7 (S3C44B0X). Applying Ethernet technology as the communication mode in the substation automation system is a new trend. The network interface chip RTL8019AS is adopted. Data transmission is realized through the in-line TCP/IP protocol of uClinux embedded OS. The application result and character analysis show that the design can meet the real-time and reliability requirements of IEC60044-7/8 electronic voltage/current instrument transformer standards.

  9. GSM-PKI solution enabling secure mobile communications.

    PubMed

    Jelekäinen, Pekka

    2004-03-31

    Because of its wide distribution and ease of use, the mobile phone, as a reliable personal communications channel, offers an excellent basis for the provision of reliable electronic communications services. In Finland, ca. 75% of the citizens have a mobile phone and, at present and most likely also in the future, it is the most widely spread service channel allowing reliable electronic communications. Despite the restricted functions of the mobile phone, the citizens can use the phone also as a communications medium. In 2001, the Finns sent over 1 billion SMS messages. In Finland, TeliaSonera Finland Oyi and the Population Register Centre (PRC) have closed a co-operation agreement with the aim of creating a mobile phone service for the electronic identification of a person. The co-operation launched is a significant development project from the perspective of the citizens. As a result, the consumers will have a new alternative for reliable electronic communications and commerce in data networks in addition to the electronic identification card. In the future, it will be possible to use the services of both public administration and the private sector by means of a mobile phone more reliably than before, without a physical visit, e.g. to a health centre or to another provider of healthcare services. The possibility of identification and signature by a mobile phone allows an easier provision of versatile services irrespective of time and place, because, in addition to voice, text message, and WAP functions, the service can be utilised also in communications services through the Internet, in which case, the mobile phone acts like a card reader. From the perspective of reliable personal mobile communications, the healthcare sector is one of the most significant and challenging application areas.

  10. 78 FR 19152 - Revisions to Modeling, Data, and Analysis Reliability Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-29

    ... processing software should be filed in native applications or print-to-PDF format and not in a scanned format...,126 (2006), aff'd sub nom. Alcoa, Inc. v. FERC, 564 F.3d 1342 (D.C. Cir. 2009). 3. In March 2007, the... print-to-PDF format and not in a scanned format. Commenters filing electronically do not need to make a...

  11. An observational analysis of provider adherence to AUA guidelines on the management of benign prostatic hyperplasia.

    PubMed

    Auffenberg, Gregory B; Gonzalez, Chris M; Wolf, J Stuart; Clemens, J Quentin; Meeks, William; McVary, Kevin T

    2014-11-01

    We retrospectively evaluated urologist adherence to the AUA guidelines on the management of new patients with benign prostatic hyperplasia related lower urinary tract symptoms in a large university urology group. All first time benign prostatic hyperplasia/lower urinary tract symptom visits to the urology clinic at the Northwestern Medical Faculty Foundation between January 1, 2008 and December 31, 2012 were evaluated using an institutionally managed electronic medical record data repository. Clinical documentation and orders from each encounter were assessed to determine the rate of performance of guideline measures. Approximately 1% of all results were manually reviewed in a validation process designed to determine the reliability of the electronic medical record based system. A total of 3,494 eligible encounters were evaluated in the final analysis. Provider adherence rates with the 9 measures recommended in the guidelines varied by measure from 53.0% to 92.8%. The rate of performance of 5 not routinely recommended measures was 10.2% or less. Post-void residual and urinary flow measurement were optional measures, and were performed on 68.1% and 4.6% of new encounters respectively. Manual validation revealed the electronic medical record data extraction was concordant with manual review in 96.7% of cases (95% CI 94.8-98.5). Using electronic medical record based data extraction techniques, we reliably document a baseline adherence rate with AUA guidelines on the management of benign prostatic hyperplasia. Establishing this benchmark will be important for future investigation into patient outcomes related to guideline adherence and into methods for improving provider adherence. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. Analytical electron microscopy as a powerful tool in plant cell biology: examples using electron energy loss spectroscopy and X-ray microanalysis.

    PubMed

    Lichtenberger, O; Neumann, D

    1997-08-01

    Energy filtering transmission electron microscopy in combination with energy dispersive X-ray analysis (EDX) and quantumchemical calculations opens new possibilities for elemental and bone analysis at the ultrastructural level. The possibilities and limitations of these methods, applied to botanical samples, are discussed and some examples are given. Ca-oxalate crystals in plant cell vacuoles show a specific C K-edge in the electron energy loss spectrum (EELS), which allows a more reliable identification than light microscopical or cytochemical methods. In some dicots crystalline inclusions can be observed in different cell compartments, which are identified as silicon dioxide or calcium silicate by the fine structure of the Si L2,3-edge. Their formation is discussed on the basis of EEL-spectra and quantumchemical calculations. Examples concerning heavy metal detoxification are given for some tolerant plants. In Minuartia Zn is bound as Zn-silicate in cell walls; Armeria accumulates Cu in leaf idioblasts by chelation with phenolic compounds and Cd is precipitated as CdS/phytochelatin-complexes in tomato.

  13. Abstracting ICU Nursing Care Quality Data From the Electronic Health Record.

    PubMed

    Seaman, Jennifer B; Evans, Anna C; Sciulli, Andrea M; Barnato, Amber E; Sereika, Susan M; Happ, Mary Beth

    2017-09-01

    The electronic health record is a potentially rich source of data for clinical research in the intensive care unit setting. We describe the iterative, multi-step process used to develop and test a data abstraction tool, used for collection of nursing care quality indicators from the electronic health record, for a pragmatic trial. We computed Cohen's kappa coefficient (κ) to assess interrater agreement or reliability of data abstracted using preliminary and finalized tools. In assessing the reliability of study data ( n = 1,440 cases) using the finalized tool, 108 randomly selected cases (10% of first half sample; 5% of last half sample) were independently abstracted by a second rater. We demonstrated mean κ values ranging from 0.61 to 0.99 for all indicators. Nursing care quality data can be accurately and reliably abstracted from the electronic health records of intensive care unit patients using a well-developed data collection tool and detailed training.

  14. Biological Signal Processing with a Genetic Toggle Switch

    PubMed Central

    Hillenbrand, Patrick; Fritz, Georg; Gerland, Ulrich

    2013-01-01

    Complex gene regulation requires responses that depend not only on the current levels of input signals but also on signals received in the past. In digital electronics, logic circuits with this property are referred to as sequential logic, in contrast to the simpler combinatorial logic without such internal memory. In molecular biology, memory is implemented in various forms such as biochemical modification of proteins or multistable gene circuits, but the design of the regulatory interface, which processes the input signals and the memory content, is often not well understood. Here, we explore design constraints for such regulatory interfaces using coarse-grained nonlinear models and stochastic simulations of detailed biochemical reaction networks. We test different designs for biological analogs of the most versatile memory element in digital electronics, the JK-latch. Our analysis shows that simple protein-protein interactions and protein-DNA binding are sufficient, in principle, to implement genetic circuits with the capabilities of a JK-latch. However, it also exposes fundamental limitations to its reliability, due to the fact that biological signal processing is asynchronous, in contrast to most digital electronics systems that feature a central clock to orchestrate the timing of all operations. We describe a seemingly natural way to improve the reliability by invoking the master-slave concept from digital electronics design. This concept could be useful to interpret the design of natural regulatory circuits, and for the design of synthetic biological systems. PMID:23874595

  15. Microstructure-Evolution and Reliability Assessment Tool for Lead-Free Component Insertion in Army Electronics

    DTIC Science & Technology

    2008-10-01

    provide adequate means for thermal heat dissipation and cooling. Thus electronic packaging has four main functions [1]: • Signal distribution which... dissipation , involving structural and materials consideration. • Mechanical, chemical and electromagnetic protection of components and... nature when compared to phenomenological models. Microelectronic packaging industry spends typically several months building and reliability

  16. Chemical effect on diffusion in intermetallic compounds

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Ting

    With the trend of big data and the Internet of things, we live in a world full of personal electronic devices and small electronic devices. In order to make the devices more powerful, advanced electronic packaging such as wafer level packaging or 3D IC packaging play an important role. Furthermore, ?-bumps, which connect silicon dies together with dimension less than 10 ?m, are crucial parts in advanced packaging. Owing to the dimension of ?-bumps, they transform into intermetallic compound from tin based solder after the liquid state bonding process. Moreover, many new reliability issues will occur in electronic packaging when the bonding materials change; in this case, we no longer have tin based solder joint, instead, we have intermetallic compound ?-bumps. Most of the potential reliability issues in intermetallic compounds are caused by the chemical reactions driven by atomic diffusion in the material; thus, to know the diffusivities of atoms inside a material is significant and can help us to further analyze the reliability issues. However, we are lacking these kinds of data in intermetallic compound because there are some problems if used traditional Darken's analysis. Therefore, we considered Wagner diffusivity in our system to solve the problems and applied the concept of chemical effect on diffusion by taking the advantage that large amount of energy will release when compounds formed. Moreover, by inventing the holes markers made by Focus ion beam (FIB), we can conduct the diffusion experiment and obtain the tracer diffusivities of atoms inside the intermetallic compound. We applied the technique on Ni3Sn4 and Cu3Sn, which are two of the most common materials in electronic packaging, and the tracer diffusivities are measured under several different temperatures; moreover, microstructure of the intermetallic compounds are investigated to ensure the diffusion environment. Additionally, the detail diffusion mechanism was also discussed in aspect of diffusion activation enthalpy and diffusion pre-factor by using lattice structure simulation. Last but not the least, X-ray photoelectron spectroscopy and First principal calculation simulation were used to observe the electron binding energies in the intermetallic compound and illustrate the partial covalent bonding behavior in the intermetallic compounds.

  17. The NASA Electronic Parts and Packaging (NEPP) Program: Insertion of New Electronics Technologies

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2007-01-01

    This viewgraph presentation gives an overview of NASA Electronic Parts and Packaging (NEPP) Program's new electronics technology trends. The topics include: 1) The Changing World of Radiation Testing of Memories; 2) Even Application-Specific Tests are Costly!; 3) Hypothetical New Technology Part Qualification Cost; 4) Where we are; 5) Approaching FPGAs as a More Than a "Part" for Reliability; 6) FPGAs Beget Novel Radiation Test Setups; 7) Understanding the Complex Radiation Data; 8) Tracking Packaging Complexity and Reliability for FPGAs; 9) Devices Supporting the FPGA Need to be Considered; 10) Summary of the New Electronic Technologies and Insertion into Flight Programs Workshop; and 11) Highlights of Panel Notes and Comments

  18. Thermal Management and Reliability of Automotive Power Electronics and Electric Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narumanchi, Sreekant V; Bennion, Kevin S; Cousineau, Justine E

    Low-cost, high-performance thermal management technologies are helping meet aggressive power density, specific power, cost, and reliability targets for power electronics and electric machines. The National Renewable Energy Laboratory is working closely with numerous industry and research partners to help influence development of components that meet aggressive performance and cost targets through development and characterization of cooling technologies, and thermal characterization and improvements of passive stack materials and interfaces. Thermomechanical reliability and lifetime estimation models are important enablers for industry in cost-and time-effective design.

  19. A fault-tolerant avionics suite for an entry research vehicle

    NASA Technical Reports Server (NTRS)

    Dzwonczyk, Mark; Stone, Howard

    1988-01-01

    A highly-reliable avionics suite has been designed for an Entry Research Vehicle. The autonomous spacecraft would be deployed from the Space Shuttle Orbiter and perform a variety of aerodynamic and propulsive maneuvers which may be required for future space transportation system vehicles. The flight electronics consist of a central fault-tolerant processor, which is resilient to all first failures, reliably cross-strapped to redundant and distributed sets of sensors and effectors. This paper describes the preliminary design and analysis of the architecture which resulted from a fifteen month study by the Charles Stark Draper Laboratory for the NASA Langley Research Center. After a brief introduction to the design task, the architecture of the central flight computer and its interface to the vehicle are discussed. Following this, the method and results of the baseline reliability study for the avionic suite are presented.

  20. A fault-tolerant avionics suite for an entry research vehicle

    NASA Astrophysics Data System (ADS)

    Dzwonczyk, Mark; Stone, Howard

    A highly-reliable avionics suite has been designed for an Entry Research Vehicle. The autonomous spacecraft would be deployed from the Space Shuttle Orbiter and perform a variety of aerodynamic and propulsive maneuvers which may be required for future space transportation system vehicles. The flight electronics consist of a central fault-tolerant processor, which is resilient to all first failures, reliably cross-strapped to redundant and distributed sets of sensors and effectors. This paper describes the preliminary design and analysis of the architecture which resulted from a fifteen month study by the Charles Stark Draper Laboratory for the NASA Langley Research Center. After a brief introduction to the design task, the architecture of the central flight computer and its interface to the vehicle are discussed. Following this, the method and results of the baseline reliability study for the avionic suite are presented.

  1. Reliability analysis of the F-8 digital fly-by-wire system

    NASA Technical Reports Server (NTRS)

    Brock, L. D.; Goodman, H. A.

    1981-01-01

    The F-8 Digital Fly-by-Wire (DFBW) flight test program intended to provide the technology for advanced control systems, giving aircraft enhanced performance and operational capability is addressed. A detailed analysis of the experimental system was performed to estimated the probabilities of two significant safety critical events: (1) loss of primary flight control function, causing reversion to the analog bypass system; and (2) loss of the aircraft due to failure of the electronic flight control system. The analysis covers appraisal of risks due to random equipment failure, generic faults in design of the system or its software, and induced failure due to external events. A unique diagrammatic technique was developed which details the combinatorial reliability equations for the entire system, promotes understanding of system failure characteristics, and identifies the most likely failure modes. The technique provides a systematic method of applying basic probability equations and is augmented by a computer program written in a modular fashion that duplicates the structure of these equations.

  2. Emission analysis of large number of various passenger electronic devices in aircraft

    NASA Astrophysics Data System (ADS)

    Schüür, Jens; Oppermann, Lukas; Enders, Achim; Nunes, Rafael R.; Oertel, Carl-Henrik

    2016-09-01

    The ever increasing use of PEDs (passenger or portable electronic devices) has put pressure on the aircraft industry as well as operators and administrations to reevaluate established restrictions in PED-use on airplanes in the last years. Any electronic device could cause electromagnetic interference to the electronics of the airplane, especially interference at receiving antennas of sensitive wireless navigation and communication (NAV/COM) systems. This paper presents a measurement campaign in an Airbus A320. 69 test passengers were asked to actively use a combination of about 150 electronic devices including many attached cables, preferentially with a high data load on their buses, to provoke maximal emissions. These emissions were analysed within the cabin as well as at the inputs of aircraft receiving antennas outside of the fuselage. The emissions of the electronic devices as well as the background noise are time-variant, so just comparing only one reference and one transmission measurement is not sufficient. Repeated measurements of both cases lead to a more reliable first analysis. Additional measurements of the absolute received power at the antennas of the airplane allow a good estimation of the real interference potential to aircraft NAV/COM systems. Although there were many measured emissions within the cabin, there were no disturbance signals detectable at the aircraft antennas.

  3. High-Resolution Infrared and Electron-Diffraction Studies of Trimethylenecyclopropane ([3]-Radialene)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, Corey; Holmes, Joshua; Nibler, Joseph W.

    2013-05-16

    Combined high-resolution spectroscopic, electron-diffraction, and quantum theoretical methods are particularly advantageous for small molecules of high symmetry and can yield accurate structures that reveal subtle effects of electron delocalization on molecular bonds. The smallest of the radialene compounds, trimethylenecyclopropane, [3]-radialene, has been synthesized and examined in the gas phase by these methods. The first high-resolution infrared spectra have been obtained for this molecule of D3h symmetry, leading to an accurate B0 rotational constant value of 0.1378629(8) cm-1, within 0.5% of the value obtained from electronic structure calculations (density functional theory (DFT) B3LYP/cc-pVTZ). This result is employed in an analysis ofmore » electron-diffraction data to obtain the rz bond lengths (in Å): C-H = 1.072 (17), C-C = 1.437 (4), and C=C = 1.330 (4). The analysis does not lead to an accurate value of the HCH angle; however, from comparisons of theoretical and experimental angles for similar compounds, the theoretical prediction of 117.5° is believed to be reliable to within 2°. The effect of electron delocalization in radialene is to reduce the single C-C bond length by 0.07 Å compared to that in cyclopropane.« less

  4. Extended performance electric propulsion power processor design study. Volume 2: Technical summary

    NASA Technical Reports Server (NTRS)

    Biess, J. J.; Inouye, L. Y.; Schoenfeld, A. D.

    1977-01-01

    Electric propulsion power processor technology has processed during the past decade to the point that it is considered ready for application. Several power processor design concepts were evaluated and compared. Emphasis was placed on a 30 cm ion thruster power processor with a beam power rating supply of 2.2KW to 10KW for the main propulsion power stage. Extension in power processor performance were defined and were designed in sufficient detail to determine efficiency, component weight, part count, reliability and thermal control. A detail design was performed on a microprocessor as the thyristor power processor controller. A reliability analysis was performed to evaluate the effect of the control electronics redesign. Preliminary electrical design, mechanical design and thermal analysis were performed on a 6KW power transformer for the beam supply. Bi-Mod mechanical, structural and thermal control configurations were evaluated for the power processor and preliminary estimates of mechanical weight were determined.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Jiajia; Zhao, Lixia, E-mail: lxzhao@semi.ac.cn, E-mail: jmli@semi.ac.cn; Cao, Haicheng

    The degradation behaviors of high power GaN-based vertical blue LEDs on Si substrates were measured using in-situ accelerated life test. The results show that the dominant failure mechanism would be different during the operation. Besides that, the corresponding associated failure mechanisms were investigated systematically by using different analysis technologies, such as Scan Electron Microscopy, Reflectivity spectroscopy, Transient Thermal Analysis, Raman Spectra, etc. It is shown that initially, the failure modes were mainly originated from the semiconductor die and interconnect, while afterwards, the following serious deterioration of the radiant fluxes was attributed to the package. The interface material and quality, suchmore » as die attach and frame, play an important role in determining the thermal performance and reliability. In addition, the heating effect during the operation will also release the compressive strain in the chip. These findings will help to improve the reliability of GaN-based LEDs, especially for the LEDs with vertical structure.« less

  6. Reliability of Next Generation Power Electronics Packaging Under Concurrent Vibration, Thermal and High Power Loads

    DTIC Science & Technology

    2008-02-01

    combined thermal g effect and initial current field. The model is implemented using Abaqus user element subroutine and verified against the experimental...Finite Element Formulation The proposed model is implemented with ABAQUS general purpose finite element program using thermal -displacement analysis...option. ABAQUS and other commercially available finite element codes do not have the capability to solve general electromigration problem directly. Thermal

  7. Postflight analysis for Delta Program Mission no. 113: COS-B Mission

    NASA Technical Reports Server (NTRS)

    1976-01-01

    On 8 August 1975, the COS-B spacecraft was launched successfully from the Western Test Range (Delta Program Mission No. 113). The launch vehicle was a three stage Extended Long Tank Delta DSV-3P-11B vehicle. Postflight analyses performed in connection with flight are presented. Vehicle trajectory, stage performance, vehicle reliability and the propulsion, guidance, flight control, electronics, mechanical and structural systems are evaluated.

  8. Design for low-power and reliable flexible electronics

    NASA Astrophysics Data System (ADS)

    Huang, Tsung-Ching (Jim)

    Flexible electronics are emerging as an alternative to conventional Si electronics for large-area low-cost applications such as e-paper, smart sensors, and disposable RFID tags. By utilizing inexpensive manufacturing methods such as ink-jet printing and roll-to-roll imprinting, flexible electronics can be made on low-cost plastics just like printing a newspaper. However, the key elements of exible electronics, thin-film transistors (TFTs), have slower operating speeds and less reliability than their Si electronics counterparts. Furthermore, depending on the material property, TFTs are usually mono-type -- either p- or n-type -- devices. Making air-stable complementary TFT circuits is very challenging and not applicable to most TFT technologies. Existing design methodologies for Si electronics, therefore, cannot be directly applied to exible electronics. Other inhibiting factors such as high supply voltage, large process variation, and lack of trustworthy device modeling also make designing larger-scale and robust TFT circuits a significant challenge. The major goal of this dissertation is to provide a viable solution for robust circuit design in exible electronics. I will first introduce a reliability simulation framework that can predict the degraded TFT circuits' performance under bias-stress. This framework has been validated using the amorphous-silicon (a-Si) TFT scan driver for TFT-LCD displays. To reuse the existing CMOS design ow for exible electronics, I propose a Pseudo-CMOS cell library that can make TFT circuits operable under low supply voltage and which has post-fabrication tunability for reliability and performance enhancement. This cell library has been validated using 2V self-assembly-monolayer (SAM) organic TFTs with a low-cost shadow-mask deposition process. I will also demonstrate a 3-bit 1.25KS/s Flash ADC in a-Si TFTs, which is based on the proposed Pseudo-CMOS cell library, and explore more possibilities in display, energy, and sensing applications.

  9. Identification of hemoglobin variants by top-down mass spectrometry using selected diagnostic product ions.

    PubMed

    Coelho Graça, Didia; Hartmer, Ralf; Jabs, Wolfgang; Beris, Photis; Clerici, Lorella; Stoermer, Carsten; Samii, Kaveh; Hochstrasser, Denis; Tsybin, Yury O; Scherl, Alexander; Lescuyer, Pierre

    2015-04-01

    Hemoglobin disorder diagnosis is a complex procedure combining several analytical steps. Due to the lack of specificity of the currently used protein analysis methods, the identification of uncommon hemoglobin variants (proteoforms) can become a hard task to accomplish. The aim of this work was to develop a mass spectrometry-based approach to quickly identify mutated protein sequences within globin chain variants. To reach this goal, a top-down electron transfer dissociation mass spectrometry method was developed for hemoglobin β chain analysis. A diagnostic product ion list was established with a color code strategy allowing to quickly and specifically localize a mutation in the hemoglobin β chain sequence. The method was applied to the analysis of rare hemoglobin β chain variants and an (A)γ-β fusion protein. The results showed that the developed data analysis process allows fast and reliable interpretation of top-down electron transfer dissociation mass spectra by nonexpert users in the clinical area.

  10. Radiation Challenges for Electronics in the Vision for Space Exploration

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.

    2006-01-01

    The slides present a brief snapshot discussing electronics and exploration-related challenges. Radiation effects have been the prime target, however, electronic parts reliability issues must also be considered. Modern electronics are designed with a 3-5 year lifetime. Upscreening does not improve reliability, merely determines inherent levels. Testing costs are driven by device complexity; they increase tester complexity, beam requirements, and facility choices. Commercial devices may improve performance, but are not cost panaceas. There is need for a more cost-effective access to high energy heavy ion facilities such as NSCL and NSRL. Costs for capable test equipment can run more than $1M for full testing.

  11. Reliability and quality EEE parts issues

    NASA Technical Reports Server (NTRS)

    Barney, Dan; Feigenbaum, Irwin

    1990-01-01

    NASA policy and procedures are established which govern the selection, testing, and application of electrical, electronic, and electromechanical (EEE) parts. Recent advances in the state-of-the-art of electronic parts and associated technologies can significantly impact the electronic designs and reliability of NASA space transportation avionics. Significant issues that result from these advances are examined, including: recent advances in microelectronics technology (as applied to or considered for use in NASA projects); electron packaging technology advances (concurrent with, and as a result of, the development of the advanced microelectronic devices); availability of parts used in space avionics; and standardization and integration of parts activities between projects, centers, and contractors.

  12. Standard Hardware Acquisition and Reliability Program's (SHARP's) efforts in incorporating fiber optic interconnects into standard electronic module (SEM) connectors

    NASA Astrophysics Data System (ADS)

    Riggs, William R.

    1994-05-01

    SHARP is a Navy wide logistics technology development effort aimed at reducing the acquisition costs, support costs, and risks of military electronic weapon systems while increasing the performance capability, reliability, maintainability, and readiness of these systems. Lower life cycle costs for electronic hardware are achieved through technology transition, standardization, and reliability enhancement to improve system affordability and availability as well as enhancing fleet modernization. Advanced technology is transferred into the fleet through hardware specifications for weapon system building blocks of standard electronic modules, standard power systems, and standard electronic systems. The product lines are all defined with respect to their size, weight, I/O, environmental performance, and operational performance. This method of defining the standard is very conducive to inserting new technologies into systems using the standard hardware. This is the approach taken thus far in inserting photonic technologies into SHARP hardware. All of the efforts have been related to module packaging; i.e. interconnects, component packaging, and module developments. Fiber optic interconnects are discussed in this paper.

  13. Influence of maternal body mass index on accuracy and reliability of external fetal monitoring techniques.

    PubMed

    Cohen, Wayne R; Hayes-Gill, Barrie

    2014-06-01

    To evaluate the performance of external electronic fetal heart rate and uterine contraction monitoring according to maternal body mass index. Secondary analysis of prospective equivalence study. Three US urban teaching hospitals. Seventy-four parturients with a normal term pregnancy. The parent study assessed performance of two methods of external fetal heart rate monitoring (abdominal fetal electrocardiogram and Doppler ultrasound) and of uterine contraction monitoring (electrohystero-graphy and tocodynamometry) compared with internal monitoring with fetal scalp electrode and intrauterine pressure transducer. Reliability of external techniques was assessed by the success rate and positive percent agreement with internal methods. Bland-Altman analysis determined accuracy. We analyzed data from that study according to maternal body mass index. We assessed the relationship between body mass index and monitor performance with linear regression, using body mass index as the independent variable and measures of reliability and accuracy as dependent variables. There was no significant association between maternal body mass index and any measure of reliability or accuracy for abdominal fetal electrocardiogram. By contrast, the overall positive percent agreement for Doppler ultrasound declined (p = 0.042), and the root mean square error from the Bland-Altman analysis increased in the first stage (p = 0.029) with increasing body mass index. Uterine contraction recordings from electrohysterography and tocodynamometry showed no significant deterioration related to maternal body mass index. Accuracy and reliability of fetal heart rate monitoring using abdominal fetal electrocardiogram was unaffected by maternal obesity, whereas performance of ultrasound degraded directly with maternal size. Both electrohysterography and tocodynamometry were unperturbed by obesity. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.

  14. An Acoustic Charge Transport Imager for High Definition Television Applications: Reliability Modeling and Parametric Yield Prediction of GaAs Multiple Quantum Well Avalanche Photodiodes. Degree awarded Oct. 1997

    NASA Technical Reports Server (NTRS)

    Hunt, W. D.; Brennan, K. F.; Summers, C. J.; Yun, Ilgu

    1994-01-01

    Reliability modeling and parametric yield prediction of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiodes (APDs), which are of interest as an ultra-low noise image capture mechanism for high definition systems, have been investigated. First, the effect of various doping methods on the reliability of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiode (APD) structures fabricated by molecular beam epitaxy is investigated. Reliability is examined by accelerated life tests by monitoring dark current and breakdown voltage. Median device lifetime and the activation energy of the degradation mechanism are computed for undoped, doped-barrier, and doped-well APD structures. Lifetimes for each device structure are examined via a statistically designed experiment. Analysis of variance shows that dark-current is affected primarily by device diameter, temperature and stressing time, and breakdown voltage depends on the diameter, stressing time and APD type. It is concluded that the undoped APD has the highest reliability, followed by the doped well and doped barrier devices, respectively. To determine the source of the degradation mechanism for each device structure, failure analysis using the electron-beam induced current method is performed. This analysis reveals some degree of device degradation caused by ionic impurities in the passivation layer, and energy-dispersive spectrometry subsequently verified the presence of ionic sodium as the primary contaminant. However, since all device structures are similarly passivated, sodium contamination alone does not account for the observed variation between the differently doped APDs. This effect is explained by the dopant migration during stressing, which is verified by free carrier concentration measurements using the capacitance-voltage technique.

  15. Die Attachment for -120 C to +20 C Thermal Cycling of Microelectronics for Future Mars Rovers: An Overview

    NASA Technical Reports Server (NTRS)

    Kirschman, Randall K.; Sokolowski, Witold M.; Kolawa, Elizabeth A.

    1999-01-01

    Active thermal control for electronics on Mars Rovers imposes a serious penalty in weight, volume, power consumption, and reliability. Thus, we propose that thermal control be eliminated for future Rovers. From a functional standpoint there is no reason that the electronics could not operate over the entire temperature range of the Martian environment, which can vary from a low of approximately equal -90 C to a high of approximately equal +20 C during the Martian night and day. The upper end of this range is well within that for conventional electronics. Although the lower end is considerably below that for which conventional--even high-reliability electronics is designed or tested, it is well established that electronic devices can operate to such low temperatures. The primary concern is reliability of the overall electronic system, especially in regard to the numerous daily temperature cycles that it would experience over the duration of a mission on Mars. Accordingly, key reliability issues have been identified for elimination of thermal control on future Mars Rovers. One of these is attachment of semiconductor die onto substrates and into packages. Die attachment is critical since it forms a mechanical, thermal and electrical interface between the electronic device and the substrate or package. This paper summarizes our initial investigation of existing information related to this issue, in order to form an opinion whether die attachment techniques exist, or could be developed with reasonable effort, to withstand the Mars thermal environment for a mission duration of approximately I year. Our conclusion, from a review of literature and personal contacts. is that die attachment can be made sufficiently reliable to satisfy the requirements of future Mars Rovers. Moreover, it appears that there are several possible techniques from which to choose and that the requirements could be met by judicious selection from existing methods using hard solders, soft solders, or organic adhesives. Thus from the standpoint of die attachment. it appears feasible to eliminate thermal control for Rover electronics. We recommend that this be further investigated and verified for the specific hardware and thermal conditions appropriate to Mars Rovers.

  16. Recent advances in electron tomography: TEM and HAADF-STEM tomography for materials science and semiconductor applications.

    PubMed

    Kübel, Christian; Voigt, Andreas; Schoenmakers, Remco; Otten, Max; Su, David; Lee, Tan-Chen; Carlsson, Anna; Bradley, John

    2005-10-01

    Electron tomography is a well-established technique for three-dimensional structure determination of (almost) amorphous specimens in life sciences applications. With the recent advances in nanotechnology and the semiconductor industry, there is also an increasing need for high-resolution three-dimensional (3D) structural information in physical sciences. In this article, we evaluate the capabilities and limitations of transmission electron microscopy (TEM) and high-angle-annular-dark-field scanning transmission electron microscopy (HAADF-STEM) tomography for the 3D structural characterization of partially crystalline to highly crystalline materials. Our analysis of catalysts, a hydrogen storage material, and different semiconductor devices shows that features with a diameter as small as 1-2 nm can be resolved in three dimensions by electron tomography. For partially crystalline materials with small single crystalline domains, bright-field TEM tomography provides reliable 3D structural information. HAADF-STEM tomography is more versatile and can also be used for high-resolution 3D imaging of highly crystalline materials such as semiconductor devices.

  17. Mobile agent application and integration in electronic anamnesis system.

    PubMed

    Liu, Chia-Hui; Chung, Yu-Fang; Chen, Tzer-Shyong; Wang, Sheng-De

    2012-06-01

    Electronic anamnesis is to transform ordinary paper trails to digitally formatted health records, which include the patient's general information, health status, and follow-ups on chronic diseases. Its main purpose is to let the records could be stored for a longer period of time and could be shared easily across departments and hospitals. Which means hospital management could use less resource on maintaining ever-growing database and reduce redundancy, so less money would be spent for managing the health records. In the foreseeable future, building up a comprehensive and integrated medical information system is a must, because it is critical to hospital resource integration and quality improvement. If mobile agent technology is adopted in the electronic anamnesis system, it would help the hospitals to make the medical practices more efficiently and conveniently. Nonetheless, most of the hospitals today are still using paper-based health records to manage the medical information. The reason why the institutions continue using traditional practices to manage the records is because there is no well-trusted and reliable electronic anamnesis system existing and accepted by both institutions and patients. The threat of privacy invasion is one of the biggest concerns when the topic of electronic anamnesis is brought up, because the security threats drag us back from using such a system. So, the medical service quality is difficult to be improved substantially. In this case, we have come up a theory to remove such security threats and make electronic anamnesis more appealing for use. Our theory is to integrate the mobile agent technology with the backbone of electronic anamnesis to construct a hierarchical access control system to retrieve the corresponding information based upon the permission classes. The system would create a classification for permission among the users inside the medical institution. Under this framework, permission control center would distribute an access key to each user, so they would only allow using the key to access information correspondingly. In order to verify the reliability of the proposed system framework, we have also conducted a security analysis to list all the possible security threats that may harm the system and to prove the system is reliable and safe. If the system is adopted, the doctors would be able to quickly access the information while performing medical examinations. Hence, the efficiency and quality of healthcare service would be greatly improved.

  18. NDE reliability and probability of detection (POD) evolution and paradigm shift

    NASA Astrophysics Data System (ADS)

    Singh, Surendra

    2014-02-01

    The subject of NDE Reliability and POD has gone through multiple phases since its humble beginning in the late 1960s. This was followed by several programs including the important one nicknamed "Have Cracks - Will Travel" or in short "Have Cracks" by Lockheed Georgia Company for US Air Force during 1974-1978. This and other studies ultimately led to a series of developments in the field of reliability and POD starting from the introduction of fracture mechanics and Damaged Tolerant Design (DTD) to statistical framework by Bernes and Hovey in 1981 for POD estimation to MIL-STD HDBK 1823 (1999) and 1823A (2009). During the last decade, various groups and researchers have further studied the reliability and POD using Model Assisted POD (MAPOD), Simulation Assisted POD (SAPOD), and applying Bayesian Statistics. All and each of these developments had one objective, i.e., improving accuracy of life prediction in components that to a large extent depends on the reliability and capability of NDE methods. Therefore, it is essential to have a reliable detection and sizing of large flaws in components. Currently, POD is used for studying reliability and capability of NDE methods, though POD data offers no absolute truth regarding NDE reliability, i.e., system capability, effects of flaw morphology, and quantifying the human factors. Furthermore, reliability and POD have been reported alike in meaning but POD is not NDE reliability. POD is a subset of the reliability that consists of six phases: 1) samples selection using DOE, 2) NDE equipment setup and calibration, 3) System Measurement Evaluation (SME) including Gage Repeatability &Reproducibility (Gage R&R) and Analysis Of Variance (ANOVA), 4) NDE system capability and electronic and physical saturation, 5) acquiring and fitting data to a model, and data analysis, and 6) POD estimation. This paper provides an overview of all major POD milestones for the last several decades and discuss rationale for using Integrated Computational Materials Engineering (ICME), MAPOD, SAPOD, and Bayesian statistics for studying controllable and non-controllable variables including human factors for estimating POD. Another objective is to list gaps between "hoped for" versus validated or fielded failed hardware.

  19. Precipitate statistics in an Al-Mg-Si-Cu alloy from scanning precession electron diffraction data

    NASA Astrophysics Data System (ADS)

    Sunde, J. K.; Paulsen, Ø.; Wenner, S.; Holmestad, R.

    2017-09-01

    The key microstructural feature providing strength to age-hardenable Al alloys is nanoscale precipitates. Alloy development requires a reliable statistical assessment of these precipitates, in order to link the microstructure with material properties. Here, it is demonstrated that scanning precession electron diffraction combined with computational analysis enable the semi-automated extraction of precipitate statistics in an Al-Mg-Si-Cu alloy. Among the main findings is the precipitate number density, which agrees well with a conventional method based on manual counting and measurements. By virtue of its data analysis objectivity, our methodology is therefore seen as an advantageous alternative to existing routines, offering reproducibility and efficiency in alloy statistics. Additional results include improved qualitative information on phase distributions. The developed procedure is generic and applicable to any material containing nanoscale precipitates.

  20. Laboratory Information Management System Chain of Custody: Reliability and Security

    PubMed Central

    Tomlinson, J. J.; Elliott-Smith, W.; Radosta, T.

    2006-01-01

    A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of automation and of data reliability can vary, and FDA- and EPA-compliant electronic signatures and system security are rare. PMID:17671623

  1. Future Directions in Navy Electronic System Reliability and Survivability.

    DTIC Science & Technology

    1981-06-01

    CENTERSAN DIEGO, CA 92152 AN ACTIVITY OF THE NAVAL MATERIAL COMMAND SL GUILLE, CAPT, USN HLBLOOD Commander Technical Director ADMINISTRATIVE INFORMATION...maintenancepoiys proposed as one remedy to these problems. To implement this policy, electronic systems which are very reliable and which include health ...distribute vital data, data-processing capability, and communication capability through the use of intraship and intership networks. The capability to

  2. Diarrhea-predominant irritable bowel syndrome: creation of an electronic version of a patient-reported outcome instrument by conversion from a pen-and-paper version and evaluation of their equivalence.

    PubMed

    Delgado-Herrera, Leticia; Banderas, Benjamin; Ojo, Oluwafunke; Kothari, Ritesh; Zeiher, Bernhardt

    2017-01-01

    Subjects with diarrhea-predominant irritable bowel syndrome (IBS-D) experience abdominal cramping, bloating, pressure, and pain. Due to an absence of clinical biomarkers for IBS-D severity, evaluation of clinical therapy benefits depends on valid and reliable symptom assessments. A patient-reported outcome (PRO) instrument has been developed, comprising of two questionnaires - the IBS-D Daily Symptom Diary and IBS-D Symptom Event Log - suitable for clinical trials and real-world settings. This program aimed to support instrument conversion from pen-and-paper to electronic format. Digital technology (Android/iOS) and a traditional mode of administration study in the target population were used to migrate or convert the validated PRO IBS-D pen-and-paper measure to an electronic format. Equivalence interviews, conducted in three waves, each had three parts: 1) conceptual equivalence testing between formats, 2) electronic-version report-history cognitive debriefing, and 3) electronic version usability evaluation. After each inter-view wave, preliminary analyses were conducted and modifications made to the electronic version, before the next wave. Final revisions were based on a full analysis of equivalence interviews. The final analysis evaluated subjects' ability to read, understand, and provide meaningful responses to the instruments across both formats. Responses were classified according to conceptual equivalence between formats and mobile-format usability assessed with a questionnaire and open-ended probes. Equivalence interviews (n=25) demonstrated conceptual equivalence between formats. Mobile-application cognitive debriefing showed some subjects experienced difficulty with font/screen visibility and understanding or reading some report-history charts and summary screens. To address difficulties, minor revisions/modifications were made and landscape orientation and zoom-in/zoom-out features incorporated. This study indicates that the two administration modes are conceptually equivalent. Since both formats are conceptually equivalent, both are psychometrically reliable, as established in the pen-and-paper version. Subjects found both mobile applications (Android/iOS) offered many advantages over the paper version, such as real-time assessment of their experience.

  3. Thermal Fatigue Evaluation of Pb-Free Solder Joints: Results, Lessons Learned, and Future Trends

    NASA Astrophysics Data System (ADS)

    Coyle, Richard J.; Sweatman, Keith; Arfaei, Babak

    2015-09-01

    Thermal fatigue is a major source of failure of solder joints in surface mount electronic components and it is critically important in high reliability applications such as telecommunication, military, and aeronautics. The electronic packaging industry has seen an increase in the number of Pb-free solder alloy choices beyond the common near-eutectic Sn-Ag-Cu alloys first established as replacements for eutectic SnPb. This paper discusses the results from Pb-free solder joint reliability programs sponsored by two industry consortia. The characteristic life in accelerated thermal cycling is reported for 12 different Pb-free solder alloys and a SnPb control in 9 different accelerated thermal cycling test profiles in terms of the effects of component type, accelerated thermal cycling profile and dwell time. Microstructural analysis on assembled and failed samples was performed to investigate the effect of initial microstructure and its evolution during accelerated thermal cycling test. A significant finding from the study is that the beneficial effect of Ag on accelerated thermal cycling reliability (measured by characteristic lifetime) diminishes as the severity of the accelerated thermal cycling, defined by greater ΔT, higher peak temperature, and longer dwell time increases. The results also indicate that all the Pb-free solders are more reliable in accelerated thermal cycling than the SnPb alloy they have replaced. Suggestions are made for future work, particularly with respect to the continued evolution of alloy development for emerging application requirements and the value of using advanced analytical methods to provide a better understanding of the effect of microstructure and its evolution on accelerated thermal cycling performance.

  4. Sleep-monitoring, experiment M133. [electronic recording system for automatic analysis of human sleep patterns

    NASA Technical Reports Server (NTRS)

    Frost, J. D., Jr.; Salamy, J. G.

    1973-01-01

    The Skylab sleep-monitoring experiment simulated the timelines and environment expected during a 56-day Skylab mission. Two crewmembers utilized the data acquisition and analysis hardware, and their sleep characteristics were studied in an online fashion during a number of all night recording sessions. Comparison of the results of online automatic analysis with those of postmission visual data analysis was favorable, confirming the feasibility of obtaining reliable objective information concerning sleep characteristics during the Skylab missions. One crewmember exhibited definite changes in certain sleep characteristics (e.g., increased sleep latency, increased time Awake during first third of night, and decreased total sleep time) during the mission.

  5. Electronic Journal Market Overview in 1997: Part 1--The Publishers.

    ERIC Educational Resources Information Center

    Machovec, George S.

    1997-01-01

    Provides an overview of the electronic journal market and focuses on publishers doing innovative projects. Discusses predominate market models; publishers and the Internet; issues surrounding electronic journals: pricing, security, electronic page layout, copyright, backfile availability, reliability, and accessibility. Highlights selected…

  6. Benefits and problems of electronic information exchange as perceived by health care professionals: an interview study

    PubMed Central

    2011-01-01

    Background Various countries are currently implementing a national electronic patient record (n-EPR). Despite the assumed positive effects of n-EPRs, their overall adoption remains low and meets resistance from health care providers. This study aims to increase our understanding of health care providers' attitude towards the n-EPR, by investigating their perceptions of the benefits and problems of electronic information exchange in health care and the n-EPR in particular. Methods The study was conducted in three Dutch health care settings: acute care, diabetes care, and ambulatory mental health care. Two health care organisations were included per setting. Between January and June 2010, interviews were conducted with 17 stakeholders working in these organisations. Relevant themes were deduced by means of thematic qualitative analysis. Results Health care providers perceived electronic information exchange to promote the efficiency and quality of care. The problems they perceived in electronic information exchange mainly concerned the confidentiality and safety of information exchange and the reliability and quality of patient data. Many problems perceived by health care providers did not specifically apply to the n-EPR, but to electronic information exchange in general. Conclusions The implementation of the Dutch n-EPR has mainly followed a top-down approach, thereby neglecting the fact that the perceptions and preferences of its users (health care providers) need to be addressed in order to achieve successful implementation. The results of this study provide valuable suggestions about how to promote health care providers' willingness to adopt electronic information exchange, which can be useful for other countries currently implementing an n-EPR. Apart from providing information about the benefits and usefulness of electronic information exchange, efforts should be focused on minimising the problems as perceived by health care providers. The safety and confidentiality of electronic information exchange can be improved by developing tools to evaluate the legitimacy of access to electronic records, by increasing health care providers' awareness of the need to be careful when using patient data, and by measures to limit access to sensitive patient data. Improving health care providers' recording behaviour is important to improve the reliability and quality of electronically exchanged patient data. PMID:21982395

  7. Benefits and problems of electronic information exchange as perceived by health care professionals: an interview study.

    PubMed

    Zwaanswijk, Marieke; Verheij, Robert A; Wiesman, Floris J; Friele, Roland D

    2011-10-07

    Various countries are currently implementing a national electronic patient record (n-EPR). Despite the assumed positive effects of n-EPRs, their overall adoption remains low and meets resistance from health care providers. This study aims to increase our understanding of health care providers' attitude towards the n-EPR, by investigating their perceptions of the benefits and problems of electronic information exchange in health care and the n-EPR in particular. The study was conducted in three Dutch health care settings: acute care, diabetes care, and ambulatory mental health care. Two health care organisations were included per setting. Between January and June 2010, interviews were conducted with 17 stakeholders working in these organisations. Relevant themes were deduced by means of thematic qualitative analysis. Health care providers perceived electronic information exchange to promote the efficiency and quality of care. The problems they perceived in electronic information exchange mainly concerned the confidentiality and safety of information exchange and the reliability and quality of patient data. Many problems perceived by health care providers did not specifically apply to the n-EPR, but to electronic information exchange in general. The implementation of the Dutch n-EPR has mainly followed a top-down approach, thereby neglecting the fact that the perceptions and preferences of its users (health care providers) need to be addressed in order to achieve successful implementation. The results of this study provide valuable suggestions about how to promote health care providers' willingness to adopt electronic information exchange, which can be useful for other countries currently implementing an n-EPR. Apart from providing information about the benefits and usefulness of electronic information exchange, efforts should be focused on minimising the problems as perceived by health care providers. The safety and confidentiality of electronic information exchange can be improved by developing tools to evaluate the legitimacy of access to electronic records, by increasing health care providers' awareness of the need to be careful when using patient data, and by measures to limit access to sensitive patient data. Improving health care providers' recording behaviour is important to improve the reliability and quality of electronically exchanged patient data.

  8. An electronic nose for reliable measurement and correct classification of beverages.

    PubMed

    Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A

    2011-01-01

    This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results.

  9. An Electronic Nose for Reliable Measurement and Correct Classification of Beverages

    PubMed Central

    Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A.

    2011-01-01

    This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results. PMID:22163964

  10. [Research on the reliability and validity of postural workload assessment method and the relation to work-related musculoskeletal disorders of workers].

    PubMed

    Qin, D L; Jin, X N; Wang, S J; Wang, J J; Mamat, N; Wang, F J; Wang, Y; Shen, Z A; Sheng, L G; Forsman, M; Yang, L Y; Wang, S; Zhang, Z B; He, L H

    2018-06-18

    To form a new assessment method to evaluate postural workload comprehensively analyzing the dynamic and static postural workload for workers during their work process to analyze the reliability and validity, and to study the relation between workers' postural workload and work-related musculoskeletal disorders (WMSDs). In the study, 844 workers from electronic and railway vehicle manufacturing factories were selected as subjects investigated by using the China Musculoskeletal Questionnaire (CMQ) to form the postural workload comprehensive assessment method. The Cronbach's α, cluster analysis and factor analysis were used to assess the reliability and validity of the new assessment method. Non-conditional Logistic regression was used to analyze the relation between workers' postural workload and WMSDs. Reliability of the assessment method for postural workload: internal consistency analysis results showed that Cronbach's α was 0.934 and the results of split-half reliability indicated that Spearman-Brown coefficient was 0.881 and the correlation coefficient between the first part and the second was 0.787. Validity of the assessment method for postural workload: the results of cluster analysis indicated that square Euclidean distance between dynamic and static postural workload assessment in the same part or work posture was the shortest. The results of factor analysis showed that 2 components were extracted and the cumulative percentage of variance achieved 65.604%. The postural workload score of the different occupational workers showed significant difference (P<0.05) by covariance analysis. The results of nonconditional Logistic regression indicated that alcohol intake (OR=2.141, 95%CI 1.337-3.428) and obesity (OR=3.408, 95%CI 1.629-7.130) were risk factors for WMSDs. The risk for WMSDs would rise as workers' postural workload rose (OR=1.035, 95%CI 1.022-1.048). There was significant different risk for WMSDs in the different groups of workers distinguished by work type, gender and age. Female workers exhibited a higher prevalence for WMSDs (OR=2.626, 95%CI 1.414-4.879) and workers between 30-40 years of age (OR=1.909, 95%CI 1.237-2.946) as compared with those under 30. This method for comprehensively assessing postural workload is reliable and effective when used in assembling workers, and there is certain relation between the postural workload and WMSDs.

  11. Electronically excited states of vitamin B12 and methylcobalamin: theoretical analysis of absorption, CD, and MCD data.

    PubMed

    Solheim, Harald; Kornobis, Karina; Ruud, Kenneth; Kozlowski, Pawel M

    2011-02-03

    Linear and quadratic response time-dependent density functional theory (TD-DFT) has been applied to investigate absorption (Abs), circular dichroism (CD), and magnetic CD (MCD) spectra of cyanocobalamin (CNCbl) and methylcobalamin (MeCbl). Although electronically excited states of both cobalamins have been probed by applying different experimental techniques, their exact nature remains poorly understood from an electronic structure point of view. Recent theoretical studies have revealed a lot of relevant information about their properties but also left some unresolved issues related to the nature of individual transitions. In this contribution, not only Abs but also CD and MCD spectra of both cobalamins were computed for direct comparison with experiment. The results were evaluated with respect to the choice of exchange-correlation functional, basis set, and the environment (gas phase or solvent) used in the calculation. Taking into account the complexity of the CNCbl and MeCbl systems, reliable agreement between theory and experiment was achieved based on calculations employing the BP86 functional, particularly for the low-energy α/β bands. This spectral range has been traditionally interpreted as a vibrational progression associated with a single electronic excitation, but according to the present analysis for both cobalamins, these bands are best interpreted as consisting of multiple electronic transitions.

  12. NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors

    NASA Technical Reports Server (NTRS)

    Sampson, Mike; Brusse, Jay

    2018-01-01

    Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.

  13. VHSIC Electronics and the Cost of Air Force Avionics in the 1990s

    DTIC Science & Technology

    1990-11-01

    circuit. LRM Line replaceable module. LRU Line replaceable unit. LSI Large-scale integration. LSTTL Tow-power Schottky Transitor -to-Transistor Logic...displays, communications/navigation/identification, electronic combat equipment, dispensers, and computers. These CERs, which statistically relate the...some of the reliability numbers, and adding the F-15 and F-16 to obtain the data sample shown in Table 6. Both suite costs and reliability statistics

  14. Experimental Study of Solder/Copper Interface Failure Under Varying Strain Rates

    DTIC Science & Technology

    2011-03-01

    Factors Affecting Solder Joint Reliability Gu et al. [1] determined that during the life cycle of electronic assemblies, approximately 55 percent of...related to vibration and shock, with the remaining percentage associated with changes in 2 humidity. Research conducted by Ross et al. [2] adds...that creep strain is the most important time-dependent factor affecting the reliability of solder joints in electronic equipment. 2. Effects of

  15. Field-Induced Crystalline-to-Amorphous Phase Transformation on the Si Nano-Apex and the Achieving of Highly Reliable Si Nano-Cathodes

    PubMed Central

    Huang, Yifeng; Deng, Zexiang; Wang, Weiliang; Liang, Chaolun; She, Juncong; Deng, Shaozhi; Xu, Ningsheng

    2015-01-01

    Nano-scale vacuum channel transistors possess merits of higher cutoff frequency and greater gain power as compared with the conventional solid-state transistors. The improvement in cathode reliability is one of the major challenges to obtain high performance vacuum channel transistors. We report the experimental findings and the physical insight into the field induced crystalline-to-amorphous phase transformation on the surface of the Si nano-cathode. The crystalline Si tip apex deformed to amorphous structure at a low macroscopic field (0.6~1.65 V/nm) with an ultra-low emission current (1~10 pA). First-principle calculation suggests that the strong electrostatic force exerting on the electrons in the surface lattices would take the account for the field-induced atomic migration that result in an amorphization. The arsenic-dopant in the Si surface lattice would increase the inner stress as well as the electron density, leading to a lower amorphization field. Highly reliable Si nano-cathodes were obtained by employing diamond like carbon coating to enhance the electron emission and thus decrease the surface charge accumulation. The findings are crucial for developing highly reliable Si-based nano-scale vacuum channel transistors and have the significance for future Si nano-electronic devices with narrow separation. PMID:25994377

  16. Test-Retest Reliability of Pediatric Heart Rate Variability: A Meta-Analysis.

    PubMed

    Weiner, Oren M; McGrath, Jennifer J

    2017-01-01

    Heart rate variability (HRV), an established index of autonomic cardiovascular modulation, is associated with health outcomes (e.g., obesity, diabetes) and mortality risk. Time- and frequency-domain HRV measures are commonly reported in longitudinal adult and pediatric studies of health. While test-retest reliability has been established among adults, less is known about the psychometric properties of HRV among infants, children, and adolescents. The objective was to conduct a meta-analysis of the test-retest reliability of time- and frequency-domain HRV measures from infancy to adolescence. Electronic searches (PubMed, PsycINFO; January 1970-December 2014) identified studies with nonclinical samples aged ≤ 18 years; ≥ 2 baseline HRV recordings separated by ≥ 1 day; and sufficient data for effect size computation. Forty-nine studies ( N = 5,170) met inclusion criteria. Methodological variables coded included factors relevant to study protocol, sample characteristics, electrocardiogram (ECG) signal acquisition and preprocessing, and HRV analytical decisions. Fisher's Z was derived as the common effect size. Analyses were age-stratified (infant/toddler < 5 years, n = 3,329; child/adolescent 5-18 years, n = 1,841) due to marked methodological differences across the pediatric literature. Meta-analytic results revealed HRV demonstrated moderate reliability; child/adolescent studies ( Z = 0.62, r = 0.55) had significantly higher reliability than infant/toddler studies ( Z = 0.42, r = 0.40). Relative to other reported measures, HF exhibited the highest reliability among infant/toddler studies ( Z = 0.42, r = 0.40), while rMSSD exhibited the highest reliability among child/adolescent studies ( Z = 1.00, r = 0.76). Moderator analyses indicated greater reliability with shorter test-retest interval length, reported exclusion criteria based on medical illness/condition, lower proportion of males, prerecording acclimatization period, and longer recording duration; differences were noted across age groups. HRV is reliable among pediatric samples. Reliability is sensitive to pertinent methodological decisions that require careful consideration by the researcher. Limited methodological reporting precluded several a priori moderator analyses. Suggestions for future research, including standards specified by Task Force Guidelines, are discussed.

  17. 17 CFR 23.202 - Daily trading records.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., instant messaging, chat rooms, electronic mail, mobile device, or other digital or electronic media. Such...; (ii) Moneys borrowed and moneys loaned; (iii) The daily calculation of the value of each outstanding... rooms, electronic mail, mobile device, or other digital or electronic media; (2) Reliable timing data...

  18. 17 CFR 23.202 - Daily trading records.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., instant messaging, chat rooms, electronic mail, mobile device, or other digital or electronic media. Such...; (ii) Moneys borrowed and moneys loaned; (iii) The daily calculation of the value of each outstanding... rooms, electronic mail, mobile device, or other digital or electronic media; (2) Reliable timing data...

  19. 75 FR 4375 - Transmission Loading Relief Reliability Standard and Curtailment Priorities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... Site: http://www.ferc.gov . Documents created electronically using word processing software should be... ensure operation within acceptable reliability criteria. NERC Glossary of Terms Used in Reliability Standards at 19, available at http://www.nerc.com/files/Glossary_12Feb08.pdf (NERC Glossary). An...

  20. Long life electrodes for large-area x-ray generators

    NASA Technical Reports Server (NTRS)

    Rothe, Dietmar E. (Inventor)

    1991-01-01

    This invention is directed to rugged, reliable, and long-life electrodes for use in large-area, high-current-density electron gun and x-ray generators which are employed as contamination-free preionizers for high-energy pulsed gas lasers. The electron source at the cathode is a corona plasma formed at the interface between a conductor, or semiconductor, and a high-permittivity dielectric. Detailed descriptions are provided of a reliable cold plasma cathode, as well as an efficient liquid-cooled electron beam target (anode) and x-ray generator which concentrates the x-ray flux in the direction of an x-ray window.

  1. NASA Electronic Parts and Packaging (NEPP) Program

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2008-01-01

    This viewgraph presentation reviews NASA's Electronic Parts and Packaging (NEPP) Program. The NEPP mission is to provide guidance to NASA for the selection and and application of microelectronics technologies, to improve understanding of the risks related to the use of these technologies in the space environment and to ensure that appropriate research is performed to meet NASA mission needs. The NEPP Program focuses on the reliability aspects of electronic devices. Three principal aspects to this reliability: (1) lifetime, (2) effects of space radiation and the space environment, and (3) creation and maintenance of the assurance support infrastructure required for success.

  2. Efficiency of optical-electronic systems: methods application for the analysis of structural changes in the process of eye grounds diagnosis

    NASA Astrophysics Data System (ADS)

    Saldan, Yosyp R.; Pavlov, Sergii V.; Vovkotrub, Dina V.; Saldan, Yulia Y.; Vassilenko, Valentina B.; Mazur, Nadia I.; Nikolaichuk, Daria V.; Wójcik, Waldemar; Romaniuk, Ryszard; Suleimenov, Batyrbek; Bainazarov, Ulan

    2017-08-01

    Process of eye tomogram obtaining by means of optical coherent tomography is studied. Stages of idiopathic macula holes formation in the process of eye grounds diagnostics are considered. Main stages of retina pathology progression are determined: Fuzzy logic units for obtaining reliable conclusions regarding the result of diagnosis are developed. By the results of theoretical and practical research system and technique of retinal macular region of the eye state analysis is developed ; application of the system, based on fuzzy logic device, improves the efficiency of eye retina complex.

  3. Risk Management of Microelectronics: The NASA Electronic Parts and Packaging (NEPP) Program

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2005-01-01

    This viewgraph information provides information on how the NASA Electronic Parts and Packaging (NEPP) Program evaluates the reliability of technologies for Electrical, Electronic, and Electromechanical (EEE) parts, and their suitability for spacecraft applications.

  4. All-inkjet-printed thin-film transistors: manufacturing process reliability by root cause analysis.

    PubMed

    Sowade, Enrico; Ramon, Eloi; Mitra, Kalyan Yoti; Martínez-Domingo, Carme; Pedró, Marta; Pallarès, Jofre; Loffredo, Fausta; Villani, Fulvia; Gomes, Henrique L; Terés, Lluís; Baumann, Reinhard R

    2016-09-21

    We report on the detailed electrical investigation of all-inkjet-printed thin-film transistor (TFT) arrays focusing on TFT failures and their origins. The TFT arrays were manufactured on flexible polymer substrates in ambient condition without the need for cleanroom environment or inert atmosphere and at a maximum temperature of 150 °C. Alternative manufacturing processes for electronic devices such as inkjet printing suffer from lower accuracy compared to traditional microelectronic manufacturing methods. Furthermore, usually printing methods do not allow the manufacturing of electronic devices with high yield (high number of functional devices). In general, the manufacturing yield is much lower compared to the established conventional manufacturing methods based on lithography. Thus, the focus of this contribution is set on a comprehensive analysis of defective TFTs printed by inkjet technology. Based on root cause analysis, we present the defects by developing failure categories and discuss the reasons for the defects. This procedure identifies failure origins and allows the optimization of the manufacturing resulting finally to a yield improvement.

  5. Comparative ex vivo evaluation of two electronic percussive testing devices measuring the stability of dental implants.

    PubMed

    Geckili, Onur; Bilhan, Hakan; Cilingir, Altug; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan

    2014-12-01

    A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra- and interobserver reliability of the wireless EPT device. Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra- and interobserver reliability of the wireless EPT device was evaluated. Statistically significant differences (P <0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P <0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter- and intraobserver reliability is good and acceptable.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tierno, S. P., E-mail: sp.tierno@upm.es; Donoso, J. M.; Domenech-Garret, J. L.

    The interaction between an electron emissive wall, electrically biased in a plasma, is revisited through a simple fluid model. We search for realistic conditions of the existence of a non-monotonic plasma potential profile with a virtual cathode as it is observed in several experiments. We mainly focus our attention on thermionic emission related to the operation of emissive probes for plasma diagnostics, although most conclusions also apply to other electron emission processes. An extended Bohm criterion is derived involving the ratio between the two different electron densities at the potential minimum and at the background plasma. The model allows amore » phase-diagram analysis, which confirms the existence of the non-monotonic potential profiles with a virtual cathode. This analysis shows that the formation of the potential well critically depends on the emitted electron current and on the velocity at the sheath edge of cold ions flowing from the bulk plasma. As a consequence, a threshold value of the governing parameter is required, in accordance to the physical nature of the electron emission process. The latter is a threshold wall temperature in the case of thermionic electrons. Experimental evidence supports our numerical calculations of this threshold temperature. Besides this, the potential well becomes deeper with increasing electron emission, retaining a fraction of the released current which limits the extent of the bulk plasma perturbation. This noninvasive property would explain the reliable measurements of plasma potential by using the floating potential method of emissive probes operating in the so-called strong emission regime.« less

  7. Electron transfer flavoprotein deficiency: functional and molecular aspects.

    PubMed

    Schiff, Manuel; Froissart, Roseline; Olsen, Rikke K J; Acquaviva, Cécile; Vianey-Saban, Christine

    2006-06-01

    Multiple acyl-CoA dehydrogenase deficiency (MADD) is a recessively inherited metabolic disorder that can be due to a deficiency of electron transfer flavoprotein (ETF) or its dehydrogenase (ETF-ubiquinone oxidoreductase). ETF is a mitochondrial matrix protein consisting of alpha- (30kDa) and beta- (28kDa) subunits encoded by the ETFA and ETFB genes, respectively. In the present study, we have analysed tissue samples from 16 unrelated patients with ETF deficiency, and we report the results of ETF activity, Western blot analysis and mutation analysis. The ETF assay provides a reliable diagnostic tool to confirm ETF deficiency in patients suspected to suffer from MADD. Activity ranged from less than 1 to 16% of controls with the most severely affected patients disclosing the lowest activity values. The majority of patients had mutations in the ETFA gene while only two of them harboured mutations in the ETFB gene. Nine novel disease-causing ETF mutations are reported.

  8. Recombination of open-f-shell tungsten ions

    NASA Astrophysics Data System (ADS)

    Krantz, C.; Badnell, N. R.; Müller, A.; Schippers, S.; Wolf, A.

    2017-03-01

    We review experimental and theoretical efforts aimed at a detailed understanding of the recombination of electrons with highly charged tungsten ions characterised by an open 4f sub-shell. Highly charged tungsten occurs as a plasma contaminant in ITER-like tokamak experiments, where it acts as an unwanted cooling agent. Modelling of the charge state populations in a plasma requires reliable thermal rate coefficients for charge-changing electron collisions. The electron recombination of medium-charged tungsten species with open 4f sub-shells is especially challenging to compute reliably. Storage-ring experiments have been conducted that yielded recombination rate coefficients at high energy resolution and well-understood systematics. Significant deviations compared to simplified, but prevalent, computational models have been found. A new class of ab initio numerical calculations has been developed that provides reliable predictions of the total plasma recombination rate coefficients for these ions.

  9. Estimating the Reliability of Electronic Parts in High Radiation Fields

    NASA Technical Reports Server (NTRS)

    Everline, Chester; Clark, Karla; Man, Guy; Rasmussen, Robert; Johnston, Allan; Kohlhase, Charles; Paulos, Todd

    2008-01-01

    Radiation effects on materials and electronic parts constrain the lifetime of flight systems visiting Europa. Understanding mission lifetime limits is critical to the design and planning of such a mission. Therefore, the operational aspects of radiation dose are a mission success issue. To predict and manage mission lifetime in a high radiation environment, system engineers need capable tools to trade radiation design choices against system design and reliability, and science achievements. Conventional tools and approaches provided past missions with conservative designs without the ability to predict their lifetime beyond the baseline mission.This paper describes a more systematic approach to understanding spacecraft design margin, allowing better prediction of spacecraft lifetime. This is possible because of newly available electronic parts radiation effects statistics and an enhanced spacecraft system reliability methodology. This new approach can be used in conjunction with traditional approaches for mission design. This paper describes the fundamentals of the new methodology.

  10. Epitaxial nickel disilicide with low resistivity and excellent reliability.

    PubMed

    Hsin, Cheng-Lun; Deng, Shiu-Sheng

    2016-02-12

    Ultra-thin epitaxial NiSi2 was formed, and its structure was examined by electron microscopy and x-ray diffraction. Compared with previous reports, the measured resistivity of the epitaxial NiSi2 was unprecedentedly low, reaching 7 μΩ cm in the experimental results and up to 14.93 μΩ cm after modification. The reliability, which was investigated under different temperatures and current densities to understand its electronic characteristics, was 1.5 times better than that of the conventional polycrystalline counterpart. Black's equation and the measured mean-time-to-failure (MTTF) were used to obtain the reliability characteristics of epitaxial and poly-NiSi2. Confidence intervals at 95% for each MTTF confirmed the single failure mode. The electromigration phenomenon was observed to be the failure mechanism. Our results provide evidence that epitaxial NiSi2 is a promising contact material for future electronics.

  11. Epitaxial nickel disilicide with low resistivity and excellent reliability

    NASA Astrophysics Data System (ADS)

    Hsin, Cheng-Lun; Deng, Shiu-Sheng

    2016-02-01

    Ultra-thin epitaxial NiSi2 was formed, and its structure was examined by electron microscopy and x-ray diffraction. Compared with previous reports, the measured resistivity of the epitaxial NiSi2 was unprecedentedly low, reaching 7 μΩ cm in the experimental results and up to 14.93 μΩ cm after modification. The reliability, which was investigated under different temperatures and current densities to understand its electronic characteristics, was 1.5 times better than that of the conventional polycrystalline counterpart. Black’s equation and the measured mean-time-to-failure (MTTF) were used to obtain the reliability characteristics of epitaxial and poly-NiSi2. Confidence intervals at 95% for each MTTF confirmed the single failure mode. The electromigration phenomenon was observed to be the failure mechanism. Our results provide evidence that epitaxial NiSi2 is a promising contact material for future electronics.

  12. Electronics for Extreme Environments

    NASA Astrophysics Data System (ADS)

    Patel, J. U.; Cressler, J.; Li, Y.; Niu, G.

    2001-01-01

    Most of the NASA missions involve extreme environments comprising radiation and low or high temperatures. Current practice of providing friendly ambient operating environment to electronics costs considerable power and mass (for shielding). Immediate missions such as the Europa orbiter and lander and Mars landers require the electronics to perform reliably in extreme conditions during the most critical part of the mission. Some other missions planned in the future also involve substantial surface activity in terms of measurements, sample collection, penetration through ice and crust and the analysis of samples. Thus it is extremely critical to develop electronics that could reliably operate under extreme space environments. Silicon On Insulator (SOI) technology is an extremely attractive candidate for NASA's future low power and high speed electronic systems because it offers increased transconductance, decreased sub-threshold slope, reduced short channel effects, elimination of kink effect, enhanced low field mobility, and immunity from radiation induced latch-up. A common belief that semiconductor devices function better at low temperatures is generally true for bulk devices but it does not hold true for deep sub-micron SOI CMOS devices with microscopic device features of 0.25 micrometers and smaller. Various temperature sensitive device parameters and device characteristics have recently been reported in the literature. Behavior of state of the art technology devices under such conditions needs to be evaluated in order to determine possible modifications in the device design for better performance and survivability under extreme environments. Here, we present a unique approach of developing electronics for extreme environments to benefit future NASA missions as described above. This will also benefit other long transit/life time missions such as the solar sail and planetary outposts in which electronics is out open in the unshielded space at the ambient space temperatures and always exposed to radiation. Additional information is contained in the original extended abstract.

  13. NASA/CARES dual-use ceramic technology spinoff applications

    NASA Technical Reports Server (NTRS)

    Powers, Lynn M.; Janosik, Lesley A.; Gyekenyesi, John P.; Nemeth, Noel N.

    1994-01-01

    NASA has developed software that enables American industry to establish the reliability and life of ceramic structures in a wide variety of 21st Century applications. Designing ceramic components to survive at higher temperatures than the capability of most metals and in severe loading environments involves the disciplines of statistics and fracture mechanics. Successful application of advanced ceramics material properties and the use of a probabilistic brittle material design methodology. The NASA program, known as CARES (Ceramics Analysis and Reliability Evaluation of Structures), is a comprehensive general purpose design tool that predicts the probability of failure of a ceramic component as a function of its time in service. The latest version of this software, CARESALIFE, is coupled to several commercially available finite element analysis programs (ANSYS, MSC/NASTRAN, ABAQUS, COSMOS/N4, MARC), resulting in an advanced integrated design tool which is adapted to the computing environment of the user. The NASA-developed CARES software has been successfully used by industrial, government, and academic organizations to design and optimize ceramic components for many demanding applications. Industrial sectors impacted by this program include aerospace, automotive, electronic, medical, and energy applications. Dual-use applications include engine components, graphite and ceramic high temperature valves, TV picture tubes, ceramic bearings, electronic chips, glass building panels, infrared windows, radiant heater tubes, heat exchangers, and artificial hips, knee caps, and teeth.

  14. Cryogenic Quenching Process for Electronic Part Screening

    NASA Technical Reports Server (NTRS)

    Sheldon, Douglas J.; Cressler, John

    2011-01-01

    The use of electronic parts at cryogenic temperatures (less than 100 C) for extreme environments is not well controlled or developed from a product quality and reliability point of view. This is in contrast to the very rigorous and well-documented procedures to qualify electronic parts for mission use in the 55 to 125 C temperature range. A similarly rigorous methodology for screening and evaluating electronic parts needs to be developed so that mission planners can expect the same level of high reliability performance for parts operated at cryogenic temperatures. A formal methodology for screening and qualifying electronic parts at cryogenic temperatures has been proposed. The methodology focuses on the base physics of failure of the devices at cryogenic temperatures. All electronic part reliability is based on the bathtub curve, high amounts of initial failures (infant mortals), a long period of normal use (random failures), and then an increasing number of failures (end of life). Unique to this is the development of custom screening procedures to eliminate early failures at cold temperatures. The ability to screen out defects will specifically impact reliability at cold temperatures. Cryogenic reliability is limited by electron trap creation in the oxide and defect sites at conductor interfaces. Non-uniform conduction processes due to process marginalities will be magnified at cryogenic temperatures. Carrier mobilities change by orders of magnitude at cryogenic temperatures, significantly enhancing the effects of electric field. Marginal contacts, impurities in oxides, and defects in conductor/conductor interfaces can all be magnified at low temperatures. The novelty is the use of an ultra-low temperature, short-duration quenching process for defect screening. The quenching process is designed to identify those defects that will precisely (and negatively) affect long-term, cryogenic part operation. This quenching process occurs at a temperature that is at least 25 C colder than the coldest expected operating temperature. This quenching process is the opposite of the standard burn-in procedure. Normal burn-in raises the temperature (and voltage) to activate quickly any possible manufacturing defects remaining in the device that were not already rejected at a functional test step. The proposed inverse burn-in or quenching process is custom-tailored to the electronic device being used. The doping profiles, materials, minimum dimensions, interfaces, and thermal expansion coefficients are all taken into account in determining the ramp rate, dwell time, and temperature.

  15. Electronics reliability fracture mechanics. Volume 1: Causes of failures of shop replaceable units and hybrid microcircuits

    NASA Astrophysics Data System (ADS)

    Kallis, J.; Buechler, D.; Erickson, J.; Westerhuyzen, D. V.; Strokes, R.

    1992-05-01

    This is the first of two volumes. The other volume (WL-TR-91-3119) is 'Fracture Mechanics'. The objective of the Electronics Reliability Fracture Mechanics (ERFM) program was to develop and demonstrate a life prediction technique for electronic assemblies, when subjected to environmental stress of vibration and thermal cycling, based upon the mechanical properties of the materials and packaging configurations which make up an electronic system. A detailed investigation was performed of the following two shop replaceable units (SRUs): Timing and Control Module (P/N 3562102) and Linear Regulator Module (P/N 3569800). The SRUs are in the Programmable Signal Processor (3137042) Line Replaceable Unit (LRU) of the Hughes AN/APG-63 Radar for the F-15 Aircraft.

  16. Investigation of abrupt degradation of drain current caused by under-gate crack in AlGaN/GaN high electron mobility transistors during high temperature operation stress

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeng, Chang; Liao, XueYang; Li, RuGuan

    2015-09-28

    In this paper, we investigate the degradation mode and mechanism of AlGaN/GaN based high electron mobility transistors (HEMTs) during high temperature operation (HTO) stress. It demonstrates that there was abrupt degradation mode of drain current during HTO stress. The abrupt degradation is ascribed to the formation of crack under the gate which was the result of the brittle fracture of epilayer based on failure analysis. The origin of the mechanical damage under the gate is further investigated and discussed based on top-down scanning electron microscope, cross section transmission electron microscope and energy dispersive x-ray spectroscopy analysis, and stress simulation. Basedmore » on the coupled analysis of the failure physical feature and stress simulation considering the coefficient of thermal expansion (CTE) mismatch in different materials in gate metals/semiconductor system, the mechanical damage under the gate is related to mechanical stress induced by CTE mismatch in Au/Ti/Mo/GaN system and stress concentration caused by the localized structural damage at the drain side of the gate edge. These results indicate that mechanical stress induced by CTE mismatch of materials inside the device plays great important role on the reliability of AlGaN/GaN HEMTs during HTO stress.« less

  17. Modeling and Verification of Dependable Electronic Power System Architecture

    NASA Astrophysics Data System (ADS)

    Yuan, Ling; Fan, Ping; Zhang, Xiao-fang

    The electronic power system can be viewed as a system composed of a set of concurrently interacting subsystems to generate, transmit, and distribute electric power. The complex interaction among sub-systems makes the design of electronic power system complicated. Furthermore, in order to guarantee the safe generation and distribution of electronic power, the fault tolerant mechanisms are incorporated in the system design to satisfy high reliability requirements. As a result, the incorporation makes the design of such system more complicated. We propose a dependable electronic power system architecture, which can provide a generic framework to guide the development of electronic power system to ease the development complexity. In order to provide common idioms and patterns to the system *designers, we formally model the electronic power system architecture by using the PVS formal language. Based on the PVS model of this system architecture, we formally verify the fault tolerant properties of the system architecture by using the PVS theorem prover, which can guarantee that the system architecture can satisfy high reliability requirements.

  18. Conformal Prediction Based on K-Nearest Neighbors for Discrimination of Ginsengs by a Home-Made Electronic Nose

    PubMed Central

    Sun, Xiyang; Miao, Jiacheng; Wang, You; Luo, Zhiyuan; Li, Guang

    2017-01-01

    An estimate on the reliability of prediction in the applications of electronic nose is essential, which has not been paid enough attention. An algorithm framework called conformal prediction is introduced in this work for discriminating different kinds of ginsengs with a home-made electronic nose instrument. Nonconformity measure based on k-nearest neighbors (KNN) is implemented separately as underlying algorithm of conformal prediction. In offline mode, the conformal predictor achieves a classification rate of 84.44% based on 1NN and 80.63% based on 3NN, which is better than that of simple KNN. In addition, it provides an estimate of reliability for each prediction. In online mode, the validity of predictions is guaranteed, which means that the error rate of region predictions never exceeds the significance level set by a user. The potential of this framework for detecting borderline examples and outliers in the application of E-nose is also investigated. The result shows that conformal prediction is a promising framework for the application of electronic nose to make predictions with reliability and validity. PMID:28805721

  19. Stretchable Electronic Sensors of Nanocomposite Network Films for Ultrasensitive Chemical Vapor Sensing.

    PubMed

    Yan, Hong; Zhong, Mengjuan; Lv, Ze; Wan, Pengbo

    2017-11-01

    A stretchable, transparent, and body-attachable chemical sensor is assembled from the stretchable nanocomposite network film for ultrasensitive chemical vapor sensing. The stretchable nanocomposite network film is fabricated by in situ preparation of polyaniline/MoS 2 (PANI/MoS 2 ) nanocomposite in MoS 2 suspension and simultaneously nanocomposite deposition onto prestrain elastomeric polydimethylsiloxane substrate. The assembled stretchable electronic sensor demonstrates ultrasensitive sensing performance as low as 50 ppb, robust sensing stability, and reliable stretchability for high-performance chemical vapor sensing. The ultrasensitive sensing performance of the stretchable electronic sensors could be ascribed to the synergistic sensing advantages of MoS 2 and PANI, higher specific surface area, the reliable sensing channels of interconnected network, and the effectively exposed sensing materials. It is expected to hold great promise for assembling various flexible stretchable chemical vapor sensors with ultrasensitive sensing performance, superior sensing stability, reliable stretchability, and robust portability to be potentially integrated into wearable electronics for real-time monitoring of environment safety and human healthcare. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Understanding the reliability of solder joints used in advanced structural and electronics applications: Part 1 - Filler metal properties and the soldering process

    DOE PAGES

    Vianco, Paul T.

    2017-02-01

    Soldering technology has made tremendous strides in the past half-century. Whether structural or electronic, all solder joints must provide a level of reliability that is required by the application. This Part 1 report examines the effects of filler metal properties and soldering process on joint reliability. Solder alloy composition must have the appropriate melting and mechanical properties that suit the product's assembly process(es) and use environment. The filler metal must also optimize solderability (wetting-and-spreading) to realize the proper joint geometry. Here, the soldering process also affects joint reliability. The choice of flux and thermal profile support the solderability performance ofmore » the molten filler metal to successfully fill the gap and complete the fillet.« less

  1. The effects of additives to SnAgCu alloys on microstructure and drop impact reliability of solder joints

    NASA Astrophysics Data System (ADS)

    Liu, Weiping; Lee, Ning-Cheng

    2007-07-01

    The impact reliability of solder joints in electronic packages is critical to the lifetime of electronic products, especially those portable devices using area array packages such as ball-grid array (BGA) and chip-scale packages (CSP). Currently, SnAgCu (SAC) solders are most widely used for lead-free applications. However, BGA and CSP solder joints using SAC alloys are fragile and prone to premature interfacial failure, especially under shock loading. To further enhance impact reliability, a family of SAC alloys doped with a small amount of additives such as Mn, Ce, Ti, Bi, and Y was developed. The effects of doping elements on drop test performance, creep resistance, and microstructure of the solder joints were investigated, and the solder joints made with the modified alloys exhibited significantly higher impact reliability.

  2. NEPP DDR Device Reliability FY13 Report

    NASA Technical Reports Server (NTRS)

    Guertin, Steven M.; Armbar, Mehran

    2014-01-01

    This document reports the status of the NEPP Double Data Rate (DDR) Device Reliability effort for FY2013. The task targeted general reliability of > 100 DDR2 devices from Hynix, Samsung, and Micron. Detailed characterization of some devices when stressed by several data storage patterns was studied, targeting ability of the data cells to store the different data patterns without refresh, highlighting the weakest bits. DDR2, Reliability, Data Retention, Temperature Stress, Test System Evaluation, General Reliability, IDD measurements, electronic parts, parts testing, microcircuits

  3. Investigation of reliability of the cutoff probe by a comparison with Thomson scattering in high density processing plasmas

    NASA Astrophysics Data System (ADS)

    Seo, Byonghoon; Kim, Dae-Woong; Kim, Jung-Hyung; You, Shinjae

    2017-12-01

    A "cutoff probe" uses microwaves to measure the electron density in a plasma. It is particularly attractive because it is easy to fabricate and use, its measurement is immune to surface contamination by dielectric materials, and it has a straightforward analysis to measure electron density in real time. In this work, we experimentally investigate the accuracy of the cutoff probe through a detailed comparison with Thomson scattering in a low temperature, high density processing plasma. The result shows that the electron density measured by the cutoff probe is lower than that by Thomson scattering and that the discrepancy of the two results becomes smaller as the gap between the two tips increases and/or the neutral gas pressure decreases. The underestimated electron density found by the cutoff probe can be explained by the influence of the probe holder, which becomes important as the pressure increases and the gap gets closer.

  4. Radiation-Tolerance Assessment of a Redundant Wireless Device

    NASA Astrophysics Data System (ADS)

    Huang, Q.; Jiang, J.

    2018-01-01

    This paper presents a method to evaluate radiation-tolerance without physical tests for a commercial off-the-shelf (COTS)-based monitoring device for high level radiation fields, such as those found in post-accident conditions in a nuclear power plant (NPP). This paper specifically describes the analysis of radiation environment in a severe accident, radiation damages in electronics, and the redundant solution used to prolong the life of the system, as well as the evaluation method for radiation protection and the analysis method of system reliability. As a case study, a wireless monitoring device with redundant and diversified channels is evaluated by using the developed method. The study results and system assessment data show that, under the given radiation condition, performance of the redundant device is more reliable and more robust than those non-redundant devices. The developed redundant wireless monitoring device is therefore able to apply in those conditions (up to 10 M Rad (Si)) during a severe accident in a NPP.

  5. Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe.

    PubMed

    Prevosto, L; Kelly, H; Mancinelli, B

    2013-12-01

    This work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that the standard exponential expression describing the electron current to the probe in collision-free plasmas can be applied under the investigated conditions. A procedure is described which allows the determination of the errors introduced in time-averaged probe data due to small-amplitude plasma fluctuations. It was found that the experimental points can be gathered into two well defined groups allowing defining two quite different averaged electron temperature values. In the low-current region the averaged characteristic was not significantly disturbed by the fluctuations and can reliably be used to obtain the actual value of the averaged electron temperature. In particular, an averaged electron temperature of 0.98 ± 0.07 eV (= 11400 ± 800 K) was found for the central core of the arc (30 A) at 3.5 mm downstream from the nozzle exit. This average included not only a time-average over the time fluctuations but also a spatial-average along the probe collecting length. The fitting of the high-current region of the characteristic using such electron temperature value together with the corrections given by the fluctuation analysis showed a relevant departure of local thermal equilibrium in the arc core.

  6. A gas chromatography/high-resolution mass spectrometry (GC/HRMS) method for determination of polybrominated diphenyl ethers in fish.

    PubMed

    Alaee, M; Sergeant, D B; Ikonomou, M G; Luross, J M

    2001-09-01

    A method for the determination of polybrominated diphenyl ethers (PBDEs) in biota for routine analysis is described. The mass spectroscopic (MS) evaluation of 23 brominated diphenyl ethers, under electron ionization and electron capture negative ion conditions using magnetic sector and quadrupole mass spectrometers, showed that high-resolution mass spectrometry (HRMS) under electron ionization conditions was the most reliable technique, with high selectivity and adequate sensitivity. The instrument detection limit for this method ranged for individual congeners between 4.8 and 0.1 pg for 3-bromodiphenyl ether (BDE-2) and 2,3',4,4'-tetrabromodiphenyl ether (BDE-66), respectively, and method detection limit for each homologue group ranged between 5 pg/g for salmon certified reference material (CRM) and 93 pg/g for lake trout CRM. The effectiveness of this method was evaluated by analyzing the occurrence of PBDEs in commercially available CRMs comprising Lake Ontario lake trout, Pacific herring, and sockeye salmon. The average coefficients of variation for the replicate analyses of PDBEs in several tissue samples were: 25% for lake trout, 36% for Pacific herring, and 34% for sockeye salmon. The average deviations in the inter-laboratory study were: 14% for lake trout, 15% for Pacific herring, and 37% for sockeye salmon. Results indicated that the described method, based on gas chromatography/high-resolution mass spectrometry, is reliable for determining PBDE concentrations in biological tissues.

  7. Electronic circuit provides automatic level control for liquid nitrogen traps

    NASA Technical Reports Server (NTRS)

    Turvy, R. R.

    1968-01-01

    Electronic circuit, based on the principle of increased thermistor resistance corresponding to decreases in temperature provides an automatic level control for liquid nitrogen cold traps. The electronically controlled apparatus is practically service-free, requiring only occasional reliability checks.

  8. The usability of a WeChat-based electronic questionnaire for collecting participant-reported data in female pelvic floor disorders: a comparison with the traditional paper-administered format.

    PubMed

    Sun, Zhi-Jing; Zhu, Lan; Liang, Maolian; Xu, Tao; Lang, Jing-He

    2016-08-01

    WeChat is a promising tool for capturing electronic data; however, no research has examined its use. This study evaluates the reliability and feasibility of WeChat for administering the Pelvic Floor Impact Questionnaire Short Form 7 questionnaire to women with pelvic floor disorders. Sixty-eight pelvic floor rehabilitation women were recruited between June and December 2015 and crossover randomized to two groups. All participants completed two questionnaire formats. One group completed the paper version followed by the WeChat version; the other group completed the questionnaires in reverse order. Two weeks later, each group completed the two versions in reverse order. The WeChat version's reliability was assessed using intraclass correlation coefficients and test-retest reliability. Forty-two women (61.8%) preferred the WeChat to the paper format, eight (11.8%) preferred the paper format, and 18 (26.5%) had no preference. The younger women preferred WeChat. Completion time was 116.5 (61.3) seconds for the WeChat version and 133.4 (107.0) seconds for the paper version, with no significant difference (P = 0.145). Age and education did not impact completion time (P > 0.05). Consistency between the WeChat and paper versions was excellent. The intraclass correlation coefficients of the Pelvic Floor Impact Questionnaire Short Form 7 and the three subscales ranged from 0.915 to 0.980. The Bland-Altman analysis and linear regression results also showed high consistency. The test-retest study had a Pearson's correlation coefficient of 0.908, demonstrating a strong correlation. WeChat-based questionnaires were well accepted by women with pelvic floor disorders and had good data quality and reliability.

  9. Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

    PubMed Central

    Gordon, J. J.; Gardner, J. K.; Wang, S.; Siebers, J. V.

    2012-01-01

    Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of ≥5% in ∼1 mm2 areas and ≥2% in ∼20 mm2 areas. Conclusions: The ability to detect small dose differences (≤2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified. PMID:22894421

  10. Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

    NASA Technical Reports Server (NTRS)

    Ghaffaroam. Reza

    2014-01-01

    Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

  11. The Validity and Reliability of an iPhone App for Measuring Running Mechanics.

    PubMed

    Balsalobre-Fernández, Carlos; Agopyan, Hovannes; Morin, Jean-Benoit

    2017-07-01

    The purpose of this investigation was to analyze the validity of an iPhone application (Runmatic) for measuring running mechanics. To do this, 96 steps from 12 different runs at speeds ranging from 2.77-5.55 m·s -1 were recorded simultaneously with Runmatic, as well as with an opto-electronic device installed on a motorized treadmill to measure the contact and aerial time of each step. Additionally, several running mechanics variables were calculated using the contact and aerial times measured, and previously validated equations. Several statistics were computed to test the validity and reliability of Runmatic in comparison with the opto-electronic device for the measurement of contact time, aerial time, vertical oscillation, leg stiffness, maximum relative force, and step frequency. The running mechanics values obtained with both the app and the opto-electronic device showed a high degree of correlation (r = .94-.99, p < .001). Moreover, there was very close agreement between instruments as revealed by the ICC (2,1) (ICC = 0.965-0.991). Finally, both Runmatic and the opto-electronic device showed almost identical reliability levels when measuring each set of 8 steps for every run recorded. In conclusion, Runmatic has been proven to be a highly reliable tool for measuring the running mechanics studied in this work.

  12. NDE reliability and probability of detection (POD) evolution and paradigm shift

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Surendra

    2014-02-18

    The subject of NDE Reliability and POD has gone through multiple phases since its humble beginning in the late 1960s. This was followed by several programs including the important one nicknamed “Have Cracks – Will Travel” or in short “Have Cracks” by Lockheed Georgia Company for US Air Force during 1974–1978. This and other studies ultimately led to a series of developments in the field of reliability and POD starting from the introduction of fracture mechanics and Damaged Tolerant Design (DTD) to statistical framework by Bernes and Hovey in 1981 for POD estimation to MIL-STD HDBK 1823 (1999) and 1823Amore » (2009). During the last decade, various groups and researchers have further studied the reliability and POD using Model Assisted POD (MAPOD), Simulation Assisted POD (SAPOD), and applying Bayesian Statistics. All and each of these developments had one objective, i.e., improving accuracy of life prediction in components that to a large extent depends on the reliability and capability of NDE methods. Therefore, it is essential to have a reliable detection and sizing of large flaws in components. Currently, POD is used for studying reliability and capability of NDE methods, though POD data offers no absolute truth regarding NDE reliability, i.e., system capability, effects of flaw morphology, and quantifying the human factors. Furthermore, reliability and POD have been reported alike in meaning but POD is not NDE reliability. POD is a subset of the reliability that consists of six phases: 1) samples selection using DOE, 2) NDE equipment setup and calibration, 3) System Measurement Evaluation (SME) including Gage Repeatability and Reproducibility (Gage R and R) and Analysis Of Variance (ANOVA), 4) NDE system capability and electronic and physical saturation, 5) acquiring and fitting data to a model, and data analysis, and 6) POD estimation. This paper provides an overview of all major POD milestones for the last several decades and discuss rationale for using Integrated Computational Materials Engineering (ICME), MAPOD, SAPOD, and Bayesian statistics for studying controllable and non-controllable variables including human factors for estimating POD. Another objective is to list gaps between “hoped for” versus validated or fielded failed hardware.« less

  13. Note: Cold spectra of the electronic transition A{sup 2}Σ{sup +}-X{sup 2}Π of N{sub 2}O{sup +} radical: High resolution analysis of the bands 000-100, 100-100, and 001-101

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lessa, L. L.; Martins, A. S.; Fellows, C. E., E-mail: fellows@if.uff.br

    2015-10-28

    In this note, three vibrational bands of the electronic transition A{sup 2}Σ{sup +}-X{sup 2}Π of the N{sub 2}O{sup +} radical (000-100, 100-100, and 001-101) were theoretically analysed. Starting from Hamiltonian models proposed for this kind of molecule, their parameters were calculated using a Levenberg-Marquardt fit procedure in order to reduce the root mean square deviation from the experimental transitions below to 0.01 cm{sup −1}. The main objective of this work is to obtain new and reliable values for rotational constant B″ and the spin-orbit interaction parameter A of the analysed vibrational levels of the X{sup 2}Π electronic state of thismore » molecule.« less

  14. Architectural development of an advanced EVA Electronic System

    NASA Technical Reports Server (NTRS)

    Lavelle, Joseph

    1992-01-01

    An advanced electronic system for future EVA missions (including zero gravity, the lunar surface, and the surface of Mars) is under research and development within the Advanced Life Support Division at NASA Ames Research Center. As a first step in the development, an optimum system architecture has been derived from an analysis of the projected requirements for these missions. The open, modular architecture centers around a distributed multiprocessing concept where the major subsystems independently process their own I/O functions and communicate over a common bus. Supervision and coordination of the subsystems is handled by an embedded real-time operating system kernel employing multitasking software techniques. A discussion of how the architecture most efficiently meets the electronic system functional requirements, maximizes flexibility for future development and mission applications, and enhances the reliability and serviceability of the system in these remote, hostile environments is included.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreno, Gilberto; Bennion, Kevin; King, Charles

    Thermal management strategies for automotive power electronic systems have evolved over time to reduce system cost and to improve reliability and thermal performance. In this study, we characterized the power electronic thermal management systems of two electric-drive vehicles--the 2012 Nissan LEAF and 2014 Honda Accord Hybrid. Tests were conducted to measure the insulated-gate bipolar transistor-to-coolant thermal resistances for both steady-state and transient conditions at various coolant flow rates. Water-ethylene glycol at a temperature of 65 degrees C was used as the coolant for these experiments. Computational fluid dynamics and finite element analysis models of the vehicle's power electronics thermal managementmore » system were then created and validated using experimentally obtained results. Results indicate that the Accord module provides lower steady-state thermal resistance as compared with the LEAF module. However, the LEAF design may provide improved performance in transient conditions and may have cost benefits.« less

  16. Computer interviewing in urogynaecology: concept, development and psychometric testing of an electronic pelvic floor assessment questionnaire in primary and secondary care.

    PubMed

    Radley, S C; Jones, G L; Tanguy, E A; Stevens, V G; Nelson, C; Mathers, N J

    2006-02-01

    To develop and evaluate a Web-based, electronic pelvic floor symptoms assessment questionnaire (e-PAQ)1 for women. A cross-sectional study in primary and secondary care. Two general practices, two community health clinics and a secondary care urogynaecology clinic. A total of 432 women (204 in primary care and 228 in secondary care) were recruited between June 2003 and January 2004. The e-PAQ was located on a workstation (computer, touchscreen and printer). Women completed the e-PAQ prior to their appointment. Untreated women in primary care were asked to return seven days later to complete the e-PAQ a second time (test-retest). Factor analysis, reliability, validity, patient satisfaction, completion times and system costs. In secondary care, factor analysis identified 14 domains within the four dimensions (urinary, bowel, vaginal and sexual symptoms) with internal consistency (Cronbach's alpha)>or=0.7 in 11 of these. In primary care, alpha values were all>or=0.7 and test-retest analysis found acceptable intraclass correlations of 0.50-0.95 (P<0.001) for all domains. A measure of face validity and utility was gained using a nine-item questionnaire, which yielded strongly positive patient views on relevance and acceptability. The e-PAQ offers a user-friendly clinical tool, which provides valid and reliable data. The system offers comprehensive symptoms and quality of life evaluation and may enhance the clinical episode as well as the quality of care for women with pelvic floor disorders.

  17. The NASA Electronic Parts and Packaging (NEPP) Program: Overview and Update FY15 and Beyond

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2016-01-01

    The NASA Electronic Parts and Packaging (NEPP) program, and its subset the NASA Electronic Parts Assurance Group (NEPAG), are NASA's point-of-contacts for reliability and radiation tolerance of electrical, electronic, and electromechanical (EEE) parts and their packages. This presentation includes a Fiscal Year 2015 program overview.

  18. NREL in the News | Transportation Research | NREL

    Science.gov Websites

    Promises Power Electronics Innovation Wide bandgap (WBG) technology promises to dramatically increase performance, reduce cost, and improve reliability of electronics packaging in electric-drive vehicles and Department's new Manufacturing Innovation Institute for Next Generation Power Electronics to accelerate

  19. NASA EEE Parts and NASA Electronic Parts and Packaging (NEPP) Program Update 2018

    NASA Technical Reports Server (NTRS)

    Label, Kenneth A.; Sampson, Michael J.; Pellish, Jonathan A.; Majewicz, Peter J.

    2018-01-01

    NASA Electronic Parts and Packaging (NEPP) Program and NASA Electronic Parts Assurance Group (NEPAG) are NASAs point-of-contacts for reliability and radiation tolerance of EEE parts and their packages. This presentation includes an FY18 program overview.

  20. A Note on the Score Reliability for the Satisfaction with Life Scale: An RG Study

    ERIC Educational Resources Information Center

    Vassar, Matt

    2008-01-01

    The purpose of the present study was to meta-analytically investigate the score reliability for the Satisfaction With Life Scale. Four-hundred and sixteen articles using the measure were located through electronic database searches and then separated to identify studies which had calculated reliability estimates from their own data. Sixty-two…

  1. 76 FR 23222 - Electric Reliability Organization Interpretation of Transmission Operations Reliability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-26

    ... applications or print-to-PDF format, and not in a scanned format, at http://www.ferc.gov/docs-filing/efiling....3d 1342 (DC Cir. 2009). \\5\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693... applications or print-to-PDF format and not in a scanned format. Commenters filing electronically do not need...

  2. Measures of Reliability in Behavioral Observation: The Advantage of "Real Time" Data Acquisition.

    ERIC Educational Resources Information Center

    Hollenbeck, Albert R.; Slaby, Ronald G.

    Two observers who were using an electronic digital data acquisition system were spot checked for reliability at random times over a four month period. Between-and within-observer reliability was assessed for frequency, duration, and duration-per-event measures of four infant behaviors. The results confirmed the problem of observer drift--the…

  3. Theory of time-resolved photoelectron imaging. Comparison of a density functional with a time-dependent density functional approach

    NASA Astrophysics Data System (ADS)

    Suzuki, Yoshi-ichi; Seideman, Tamar; Stener, Mauro

    2004-01-01

    Time-resolved photoelectron differential cross sections are computed within a quantum dynamical theory that combines a formally exact solution of the nuclear dynamics with density functional theory (DFT)-based approximations of the electronic dynamics. Various observables of time-resolved photoelectron imaging techniques are computed at the Kohn-Sham and at the time-dependent DFT levels. Comparison of the results serves to assess the reliability of the former method and hence its usefulness as an economic approach for time-domain photoelectron cross section calculations, that is applicable to complex polyatomic systems. Analysis of the matrix elements that contain the electronic dynamics provides insight into a previously unexplored aspect of femtosecond-resolved photoelectron imaging.

  4. Excited state dynamics of thiophene and bithiophene: new insights into theoretically challenging systems.

    PubMed

    Prlj, Antonio; Curchod, Basile F E; Corminboeuf, Clémence

    2015-06-14

    The computational elucidation and proper description of the ultrafast deactivation mechanisms of simple organic electronic units, such as thiophene and its oligomers, is as challenging as it is contentious. A comprehensive excited state dynamics analysis of these systems utilizing reliable electronic structure approaches is currently lacking, with earlier pictures of the photochemistry of these systems being conceived based upon high-level static computations or lower level dynamic trajectories. Here a detailed surface hopping molecular dynamics of thiophene and bithiophene using the algebraic diagrammatic construction to second order (ADC(2)) method is presented. Our findings illustrate that ring puckering plays an important role in thiophene photochemistry and that the photostability increases when going upon dimerization into bithiophene.

  5. Care team identification in the electronic health record: A critical first step for patient-centered communication.

    PubMed

    Dalal, Anuj K; Schnipper, Jeffrey L

    2016-05-01

    Patient-centered communication is essential to coordinate care and safely progress patients from admission through discharge. Hospitals struggle with improving the complex and increasingly electronic conversation patterns among care team members, patients, and caregivers to achieve effective patient-centered communication across settings. Accurate and reliable identification of all care team members is a precursor to effective patient-centered communication and ideally should be facilitated by the electronic health record. However, the process of identifying care team members is challenging, and team lists in the electronic health record are typically neither accurate nor reliable. Based on the literature and on experience from 2 initiatives at our institution, we outline strategies to improve care team identification in the electronic health record and discuss potential implications for patient-centered communication. Journal of Hospital Medicine 2016;11:381-385. © 2016 Society of Hospital Medicine. © 2016 Society of Hospital Medicine.

  6. Lithium-Ion Technology for Aerospace Applications- Advancing Battery Management Electronics

    NASA Astrophysics Data System (ADS)

    Gitzendanner, R.; Jones, E.; Deory, C.; Carmen, D.

    2005-05-01

    Lithium-ion technology offers a unique, weight and volume saving, solution to the power storage needs of space applications. With higher energy and power densities than conventional technologies, such as Nickel-Hydrogen (Ni-H) and Nickel/Cadmium (Ni- Cd), and comparable cycle life and reliability, Lithium-ion technology is gaining interest in many space applications. As the demand for Lithium-ion batteries with high reliability and long life increases, the need for battery management electronics, including individual cell balancing and monitoring, becomes apparent. With onboard electronics, the cells are monitored individually, and are protected from over charge or over discharge by way of integral protection circuitry. State of Charge, State of Health and other useful telemetry can also be calculated by the integrated electronics and reported to the application. Lab-based, and real-life, testing and use of these battery systems has shown the advantages of an integrated electronics package.

  7. Electrostatically Driven Nanoballoon Actuator.

    PubMed

    Barzegar, Hamid Reza; Yan, Aiming; Coh, Sinisa; Gracia-Espino, Eduardo; Dunn, Gabriel; Wågberg, Thomas; Louie, Steven G; Cohen, Marvin L; Zettl, Alex

    2016-11-09

    We demonstrate an inflatable nanoballoon actuator based on geometrical transitions between the inflated (cylindrical) and collapsed (flattened) forms of a carbon nanotube. In situ transmission electron microscopy experiments employing a nanoelectromechanical manipulator show that a collapsed carbon nanotube can be reinflated by electrically charging the nanotube, thus realizing an electrostatically driven nanoballoon actuator. We find that the tube actuator can be reliably cycled with only modest control voltages (few volts) with no apparent wear or fatigue. A complementary theoretical analysis identifies critical parameters for nanotube nanoballoon actuation.

  8. ESREF 98 - 9th European Symposium on Reliability of Electron Devices, Failure Physics and Analysis

    DTIC Science & Technology

    1998-10-19

    Gap effects within a nanosecond time scale. Effective Density of States Because of the limited possibility of compact Mobility models to deal with the...brackets) and the dislocation source action mobility M. The force is the balance between the normal stress a,, on the dislocations and the osmotic The...on, the electromigration force acts theration kt. on the atoms and a transport to the anode side of the t It is the mobility term that accounts for

  9. The virtual cooperation platform in enterprise and supplier cooperation models.

    PubMed

    Chang, Che-Wei; Wu, Cheng-Ru; Liao, Chia-Chun

    2010-08-01

    Abstract This study examines the use of the virtual enterprise network supplier supply-chain model of business behavior in creating synergies of cooperation. To explore virtual network behavior, it evaluates 60 samples, taken from of a few supply chains, and 17 items meeting certain behavioral criteria. Such an analysis may help to reduce costs and processing time effectively, as well as promote effective communication. Furthermore, the study of behavior in this electronic setting is a reliable and useful assessment method.

  10. Highly reliable field electron emitters produced from reproducible damage-free carbon nanotube composite pastes with optimal inorganic fillers.

    PubMed

    Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho

    2014-02-14

    Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10,000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm(-2). The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.

  11. Highly reliable field electron emitters produced from reproducible damage-free carbon nanotube composite pastes with optimal inorganic fillers

    NASA Astrophysics Data System (ADS)

    Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho

    2014-02-01

    Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10 000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm-2. The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.

  12. An Energy-Based Three-Dimensional Segmentation Approach for the Quantitative Interpretation of Electron Tomograms

    PubMed Central

    Bartesaghi, Alberto; Sapiro, Guillermo; Subramaniam, Sriram

    2006-01-01

    Electron tomography allows for the determination of the three-dimensional structures of cells and tissues at resolutions significantly higher than that which is possible with optical microscopy. Electron tomograms contain, in principle, vast amounts of information on the locations and architectures of large numbers of subcellular assemblies and organelles. The development of reliable quantitative approaches for the analysis of features in tomograms is an important problem, and a challenging prospect due to the low signal-to-noise ratios that are inherent to biological electron microscopic images. This is, in part, a consequence of the tremendous complexity of biological specimens. We report on a new method for the automated segmentation of HIV particles and selected cellular compartments in electron tomograms recorded from fixed, plastic-embedded sections derived from HIV-infected human macrophages. Individual features in the tomogram are segmented using a novel robust algorithm that finds their boundaries as global minimal surfaces in a metric space defined by image features. The optimization is carried out in a transformed spherical domain with the center an interior point of the particle of interest, providing a proper setting for the fast and accurate minimization of the segmentation energy. This method provides tools for the semi-automated detection and statistical evaluation of HIV particles at different stages of assembly in the cells and presents opportunities for correlation with biochemical markers of HIV infection. The segmentation algorithm developed here forms the basis of the automated analysis of electron tomograms and will be especially useful given the rapid increases in the rate of data acquisition. It could also enable studies of much larger data sets, such as those which might be obtained from the tomographic analysis of HIV-infected cells from studies of large populations. PMID:16190467

  13. Effect of spontaneous saliva swallowing on short-term heart rate variability (HRV) and reliability of HRV analysis.

    PubMed

    Yildiz, Metin; Doma, Serian

    2017-09-26

    The effects of effortful swallowing and solid meal ingestions on heart rate variability (HRV) have been examined previously. The effects of spontaneous saliva swallowing on short-term HRV and reliability of HRV analysis have not been studied before. The effect of saliva swallowing on HRV analyses parameters [meanRRI, SDNN (standard deviation of normal-to-normal), LF (low frequency), HF (high frequency) powers, LH/HF] and the reliability of LF and HF powers were investigated by frequency, time-frequency and intraclass correlation coefficient (ICC) analyses. Electrocardiogram and swallowing signal that obtained from an electronic stethoscope placed on the necks of subjects were recorded simultaneously from 30 healthy and young volunteers in sitting position during 15 min. Spontaneous swallowing has been shown to significantly alter some HRV parameters (SDNN, LF power and LF/HF ratio). Time-frequency analysis results showed that the contribution of saliva swallowing to LF (1-58%) and HF (2-42%) powers could change significantly depending on the number of swallowing. The ICC of the LF and HF powers for the successive 5-min signal segments were found 0·89, 0·92, respectively. These values decreased to 0·73 and 0·90 in the subjects with more swallowing rate. When the analyses were made for 2-min signal periods, these values decreased to 0·63 and 0·67. We concluded that spontaneous saliva swallowing can change HRV parameters. We have also seen that changes in swallowing rate and use of short signal segments may reduce the reliability of HRV analyses. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  14. A Probabilistic Approach for Reliability and Life Prediction of Electronics in Drilling and Evaluation Tools

    DTIC Science & Technology

    2014-12-23

    A Probabilistic Approach for Reliability and Life Prediction of Electronics in Drilling and Evaluation Tools Amit A. Kale 1 , Katrina Carter...dielectric breakdown has been Amit Kale et al. This is an open-access article distributed under the terms of the Creative Commons Attribution 3.0...160.doi 10.1016/S0167- 4730(00)00005-9. BIOGRAPHIES Amit A. Kale was born in Bhopal, India on October 25 1978. He earned PhD in 2005 and MS in

  15. Hot electron generation under large-signal radio frequency operation of GaN high-electron-mobility transistors

    NASA Astrophysics Data System (ADS)

    Latorre-Rey, Alvaro D.; Sabatti, Flavio F. M.; Albrecht, John D.; Saraniti, Marco

    2017-07-01

    In order to assess the underlying physical mechanisms of hot carrier-related degradation such as defect generation in millimeter-wave GaN power amplifiers, we have simulated the electron energy distribution function under large-signal radio frequency conditions in AlGaN/GaN high-electron-mobility transistors. Our results are obtained through a full band Monte Carlo particle-based simulator self-consistently coupled to a harmonic balance circuit solver. At lower frequency, simulations of a Class AB power amplifier at 10 GHz show that the peak hot electron generation is up to 43% lower under RF drive than it is under DC conditions, regardless of the input power or temperature of operation. However, at millimeter-wave operation up to 40 GHz, RF hot carrier generation reaches that from DC biasing and even exceeds it up to 75% as the amplifier is driven into compression. Increasing the temperature of operation also shows that degradation of DC and RF characteristics are tightly correlated and mainly caused by increased phonon scattering. The accurate determination of the electron energy mapping is demonstrated to be a powerful tool for the extraction of compact models used in lifetime and reliability analysis.

  16. An experimental and theoretical investigation into the electronically excited states of para-benzoquinone

    NASA Astrophysics Data System (ADS)

    Jones, D. B.; Limão-Vieira, P.; Mendes, M.; Jones, N. C.; Hoffmann, S. V.; da Costa, R. F.; Varella, M. T. do N.; Bettega, M. H. F.; Blanco, F.; García, G.; Ingólfsson, O.; Lima, M. A. P.; Brunger, M. J.

    2017-05-01

    We report on a combination of experimental and theoretical investigations into the structure of electronically excited para-benzoquinone (pBQ). Here synchrotron photoabsorption measurements are reported over the 4.0-10.8 eV range. The higher resolution obtained reveals previously unresolved pBQ spectral features. Time-dependent density functional theory calculations are used to interpret the spectrum and resolve discrepancies relating to the interpretation of the Rydberg progressions. Electron-impact energy loss experiments are also reported. These are combined with elastic electron scattering cross section calculations performed within the framework of the independent atom model-screening corrected additivity rule plus interference (IAM-SCAR + I) method to derive differential cross sections for electronic excitation of key spectral bands. A generalized oscillator strength analysis is also performed, with the obtained results demonstrating that a cohesive and reliable quantum chemical structure and cross section framework has been established. Within this context, we also discuss some issues associated with the development of a minimal orbital basis for the single configuration interaction strategy to be used for our high-level low-energy electron scattering calculations that will be carried out as a subsequent step in this joint experimental and theoretical investigation.

  17. Microbial Biofilm Voltammetry: Direct Electrochemical Characterization of Catalytic Electrode-Attached Biofilms▿ †

    PubMed Central

    Marsili, Enrico; Rollefson, Janet B.; Baron, Daniel B.; Hozalski, Raymond M.; Bond, Daniel R.

    2008-01-01

    While electrochemical characterization of enzymes immobilized on electrodes has become common, there is still a need for reliable quantitative methods for study of electron transfer between living cells and conductive surfaces. This work describes growth of thin (<20 μm) Geobacter sulfurreducens biofilms on polished glassy carbon electrodes, using stirred three-electrode anaerobic bioreactors controlled by potentiostats and nondestructive voltammetry techniques for characterization of viable biofilms. Routine in vivo analysis of electron transfer between bacterial cells and electrodes was performed, providing insight into the main redox-active species participating in electron transfer to electrodes. At low scan rates, cyclic voltammetry revealed catalytic electron transfer between cells and the electrode, similar to what has been observed for pure enzymes attached to electrodes under continuous turnover conditions. Differential pulse voltammetry and electrochemical impedance spectroscopy also revealed features that were consistent with electron transfer being mediated by an adsorbed catalyst. Multiple redox-active species were detected, revealing complexity at the outer surfaces of this bacterium. These techniques provide the basis for cataloging quantifiable, defined electron transfer phenotypes as a function of potential, electrode material, growth phase, and culture conditions and provide a framework for comparisons with other species or communities. PMID:18849456

  18. 2015 Inverter Workshop | Photovoltaic Research | NREL

    Science.gov Websites

    Utility PV Inverters-Ron Vidano, Advanced Energy Module Level Power Electronics-Jack Flicker (Chair ), Sandia National Laboratories Standardization and Reliability Testing of Module-Level Power Electronics Failure Modes in Inverters-Diganta Das, CALCE Corrosion of Electronics-Rob Sorensen, Sandia National

  19. Characterization of shape and deformation of MEMS by quantitative optoelectronic metrology techniques

    NASA Astrophysics Data System (ADS)

    Furlong, Cosme; Pryputniewicz, Ryszard J.

    2002-06-01

    Recent technological trends based on miniaturization of mechanical, electro-mechanical, and photonic devices to the microscopic scale, have led to the development of microelectromechanical systems (MEMS). Effective development of MEMS components requires the synergism of advanced design, analysis, and fabrication methodologies, and also of quantitative metrology techniques for characterizing their performance, reliability, and integrity during the electronic packaging cycle. In this paper, we describe opto-electronic techniques for measuring, with sub-micrometer accuracy, shape and changes in states of deformation of MEMS strictures. With the described opto-electronic techniques, it is possible to characterize MEMS components using the display and data modes. In the display mode, interferometric information related to shape and deformation is displayed at video frame rates, providing the capability for adjusting and setting experimental conditions. In the data mode, interferometric information related to shape and deformation is recorded as high-spatial and high-digital resolution images, which are further processed to provide quantitative 3D information. Furthermore, the quantitative 3D data are exported to computer-aided design (CAD) environments and utilized for analysis and optimization of MEMS devices. Capabilities of opto- electronic techniques are illustrated with representative applications demonstrating their applicability to provide indispensable quantitative information for the effective development and optimization of MEMS devices.

  20. Reliability of high I/O high density CCGA interconnect electronic packages under extreme thermal environments

    NASA Astrophysics Data System (ADS)

    Ramesham, Rajeshuni

    2012-03-01

    Ceramic column grid array (CCGA) packages have been increasing in use based on their advantages such as high interconnect density, very good thermal and electrical performances, compatibility with standard surfacemount packaging assembly processes, and so on. CCGA packages are used in space applications such as in logic and microprocessor functions, telecommunications, payload electronics, and flight avionics. As these packages tend to have less solder joint strain relief than leaded packages or more strain relief over lead-less chip carrier packages, the reliability of CCGA packages is very important for short-term and long-term deep space missions. We have employed high density CCGA 1152 and 1272 daisy chained electronic packages in this preliminary reliability study. Each package is divided into several daisy-chained sections. The physical dimensions of CCGA1152 package is 35 mm x 35 mm with a 34 x 34 array of columns with a 1 mm pitch. The dimension of the CCGA1272 package is 37.5 mm x 37.5 mm with a 36 x 36 array with a 1 mm pitch. The columns are made up of 80% Pb/20%Sn material. CCGA interconnect electronic package printed wiring polyimide boards have been assembled and inspected using non-destructive x-ray imaging techniques. The assembled CCGA boards were subjected to extreme temperature thermal atmospheric cycling to assess their reliability for future deep space missions. The resistance of daisy-chained interconnect sections were monitored continuously during thermal cycling. This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions.

  1. Reliability of High I/O High Density CCGA Interconnect Electronic Packages under Extreme Thermal Environment

    NASA Technical Reports Server (NTRS)

    Ramesham, Rajeshuni

    2012-01-01

    This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions. Ceramic column grid array (CCGA) packages have been increasing in use based on their advantages such as high interconnect density, very good thermal and electrical performances, compatibility with standard surface-mount packaging assembly processes, and so on. CCGA packages are used in space applications such as in logic and microprocessor functions, telecommunications, payload electronics, and flight avionics. As these packages tend to have less solder joint strain relief than leaded packages or more strain relief over lead-less chip carrier packages, the reliability of CCGA packages is very important for short-term and long-term deep space missions. We have employed high density CCGA 1152 and 1272 daisy chained electronic packages in this preliminary reliability study. Each package is divided into several daisy-chained sections. The physical dimensions of CCGA1152 package is 35 mm x 35 mm with a 34 x 34 array of columns with a 1 mm pitch. The dimension of the CCGA1272 package is 37.5 mm x 37.5 mm with a 36 x 36 array with a 1 mm pitch. The columns are made up of 80% Pb/20%Sn material. CCGA interconnect electronic package printed wiring polyimide boards have been assembled and inspected using non-destructive x-ray imaging techniques. The assembled CCGA boards were subjected to extreme temperature thermal atmospheric cycling to assess their reliability for future deep space missions. The resistance of daisy-chained interconnect sections were monitored continuously during thermal cycling. This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions. Keywords: Extreme temperatures, High density CCGA qualification, CCGA reliability, solder joint failures, optical inspection, and x-ray inspection.

  2. Exploration of multi-fold symmetry element-loaded superconducting radio frequency structure for reliable acceleration of low- & medium-beta ion species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Shichun; Geng, Rongli

    2015-09-01

    Reliable acceleration of low- to medium-beta proton or heavy ion species is needed for future high-current superconducting radio frequency (SRF) accelerators. Due to the high-Q nature of an SRF resonator, it is sensitive to many factors such as electron loading (from either the accelerated beam or from parasitic field emitted electrons), mechanical vibration, and liquid helium bath pressure fluctuation etc. To increase the stability against those factors, a mechanically strong and stable RF structure is desirable. Guided by this consideration, multi-fold symmetry element-loaded SRF structures (MFSEL), cylindrical tanks with multiple (n>=3) rod-shaped radial elements, are being explored. The top goalmore » of its optimization is to improve mechanical stability. A natural consequence of this structure is a lowered ratio of the peak surface electromagnetic field to the acceleration gradient as compared to the traditional spoke cavity. A disadvantage of this new structure is an increased size for a fixed resonant frequency and optimal beta. This paper describes the optimization of the electro-magnetic (EM) design and preliminary mechanical analysis for such structures.« less

  3. Reliability- and performance-based robust design optimization of MEMS structures considering technological uncertainties

    NASA Astrophysics Data System (ADS)

    Martowicz, Adam; Uhl, Tadeusz

    2012-10-01

    The paper discusses the applicability of a reliability- and performance-based multi-criteria robust design optimization technique for micro-electromechanical systems, considering their technological uncertainties. Nowadays, micro-devices are commonly applied systems, especially in the automotive industry, taking advantage of utilizing both the mechanical structure and electronic control circuit on one board. Their frequent use motivates the elaboration of virtual prototyping tools that can be applied in design optimization with the introduction of technological uncertainties and reliability. The authors present a procedure for the optimization of micro-devices, which is based on the theory of reliability-based robust design optimization. This takes into consideration the performance of a micro-device and its reliability assessed by means of uncertainty analysis. The procedure assumes that, for each checked design configuration, the assessment of uncertainty propagation is performed with the meta-modeling technique. The described procedure is illustrated with an example of the optimization carried out for a finite element model of a micro-mirror. The multi-physics approach allowed the introduction of several physical phenomena to correctly model the electrostatic actuation and the squeezing effect present between electrodes. The optimization was preceded by sensitivity analysis to establish the design and uncertain domains. The genetic algorithms fulfilled the defined optimization task effectively. The best discovered individuals are characterized by a minimized value of the multi-criteria objective function, simultaneously satisfying the constraint on material strength. The restriction of the maximum equivalent stresses was introduced with the conditionally formulated objective function with a penalty component. The yielded results were successfully verified with a global uniform search through the input design domain.

  4. Effect of Pd Surface Roughness on the Bonding Process and High Temperature Reliability of Au Ball Bonds

    NASA Astrophysics Data System (ADS)

    Huang, Y.; Kim, H. J.; McCracken, M.; Viswanathan, G.; Pon, F.; Mayer, M.; Zhou, Y. N.

    2011-06-01

    A 0.3- μm-thick electrolytic Pd layer was plated on 1 μm of electroless Ni on 1 mm-thick polished and roughened Cu substrates with roughness values ( R a) of 0.08 μm and 0.5 μm, respectively. The rough substrates were produced with sand-blasting. Au wire bonding on the Ni/Pd surface was optimized, and the electrical reliability was investigated under a high temperature storage test (HTST) during 800 h at 250°C by measuring the ball bond contact resistance, R c. The average value of R c of optimized ball bonds on the rough substrate was 1.96 mΩ which was about 40.0% higher than that on the smooth substrate. The initial bondability increased for the rougher surface, so that only half of the original ultrasonic level was required, but the reliability was not affected by surface roughness. For both substrate types, HTST caused bond healing, reducing the average R c by about 21% and 27%, respectively. Au diffusion into the Pd layer was observed in scanning transmission electron microscopy/ energy dispersive spectroscopy (STEM-EDS) line-scan analysis after HTST. It is considered that diffusion of Au or interdiffusion between Au and Pd can provide chemically strong bonding during HTST. This is supported by the R c decrease measured as the aging time increased. Cu migration was indicated in the STEM-EDS analysis, but its effect on reliability can be ignored. Au and Pd tend to form a complete solid solution at the interface and can provide reliable interconnection for high temperature (250°C) applications.

  5. A realistic analysis of the phonon growth characteristics in a degenerate semiconductor using a simplified model of Fermi-Dirac distribution

    NASA Astrophysics Data System (ADS)

    Basu, A.; Das, B.; Middya, T. R.; Bhattacharya, D. P.

    2017-01-01

    The phonon growth characteristic in a degenerate semiconductor has been calculated under the condition of low temperature. If the lattice temperature is high, the energy of the intravalley acoustic phonon is negligibly small compared to the average thermal energy of the electrons. Hence one can traditionally assume the electron-phonon collisions to be elastic and approximate the Bose-Einstein (B.E.) distribution for the phonons by the simple equipartition law. However, in the present analysis at the low lattice temperatures, the interaction of the non equilibrium electrons with the acoustic phonons becomes inelastic and the simple equipartition law for the phonon distribution is not valid. Hence the analysis is made taking into account the inelastic collisions and the complete form of the B.E. distribution. The high-field distribution function of the carriers given by Fermi-Dirac (F.D.) function at the field dependent carrier temperature, has been approximated by a well tested model that apparently overcomes the intrinsic problem of correct evaluation of the integrals involving the product and powers of the Fermi function. Hence the results thus obtained are more reliable compared to the rough estimation that one may obtain from using the exact F.D. function, but taking recourse to some over simplified approximations.

  6. Choice of range-energy relationship for the analysis of electron-beam-induced-current line scans

    NASA Astrophysics Data System (ADS)

    Luke, Keung, L.

    1994-07-01

    The electron range in a material is an important parameter in the analysis of electron-beam-induced-current (EBIC) line scans. Both the Kanaya-Okayama (KO) and Everhart-Hoff (EH) range-energy relationships have been widely used by investigators for this purpose. Although the KO range is significantly larer than the EH range, no study has been done to examine the effect of choosing one range over the other on the values of the surface recombination velocity S(sub T) and minority-carrier diffusion length L evaluated from EBICF line scans. Such a study has been carried out, focusing on two major questions: (1) When the KO range is used in different reported methods to evaluate either or both S(sub T) and L from EBIC line scans, how different are their values thus determined in comparison to those using the EH range?; (2) from EBIC line scans of a given material, is there a way to discriminate between the KO and the EH ranges which should be used to analyze these scans? Answers to these questions are presented to assist investigators in extracting more reliable values of either or both S(sub T) and L and in finding the right range to use in the analysis of these line scans.

  7. Sprayed shielding of plastic-encapsulated electronic modules

    NASA Technical Reports Server (NTRS)

    Muller, A. N.

    1969-01-01

    Metallic coating directly sprayed on electronic modules provides simple and reliable lightweight protection against radio frequency interference. A plasma arc may be used. Aluminum and copper are the most effective metals.

  8. The Outdoor MEDIA DOT: The development and inter-rater reliability of a tool designed to measure food and beverage outlets and outdoor advertising.

    PubMed

    Poulos, Natalie S; Pasch, Keryn E

    2015-07-01

    Few studies of the food environment have collected primary data, and even fewer have reported reliability of the tool used. This study focused on the development of an innovative electronic data collection tool used to document outdoor food and beverage (FB) advertising and establishments near 43 middle and high schools in the Outdoor MEDIA Study. Tool development used GIS based mapping, an electronic data collection form on handheld devices, and an easily adaptable interface to efficiently collect primary data within the food environment. For the reliability study, two teams of data collectors documented all FB advertising and establishments within one half-mile of six middle schools. Inter-rater reliability was calculated overall and by advertisement or establishment category using percent agreement. A total of 824 advertisements (n=233), establishment advertisements (n=499), and establishments (n=92) were documented (range=8-229 per school). Overall inter-rater reliability of the developed tool ranged from 69-89% for advertisements and establishments. Results suggest that the developed tool is highly reliable and effective for documenting the outdoor FB environment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. The Outdoor MEDIA DOT: The Development and Inter-Rater Reliability of a Tool Designed to Measure Food and Beverage Outlets and Outdoor Advertising

    PubMed Central

    Poulos, Natalie S.; Pasch, Keryn E.

    2015-01-01

    Few studies of the food environment have collected primary data, and even fewer have reported reliability of the tool used. This study focused on the development of an innovative electronic data collection tool used to document outdoor food and beverage (FB) advertising and establishments near 43 middle and high schools in the Outdoor MEDIA Study. Tool development used GIS based mapping, an electronic data collection form on handheld devices, and an easily adaptable interface to efficiently collect primary data within the food environment. For the reliability study, two teams of data collectors documented all FB advertising and establishments within one half-mile of six middle schools. Inter-rater reliability was calculated overall and by advertisement or establishment category using percent agreement. A total of 824 advertisements (n=233), establishment advertisements (n=499), and establishments (n=92) were documented (range=8–229 per school). Overall inter-rater reliability of the developed tool ranged from 69–89% for advertisements and establishments. Results suggest that the developed tool is highly reliable and effective for documenting the outdoor FB environment. PMID:26022774

  10. Novel High Integrity Bio-Inspired Systems with On-Line Self-Test and Self-Repair Properties

    NASA Astrophysics Data System (ADS)

    Samie, Mohammad; Dragffy, Gabriel; Pipe, Tony

    2011-08-01

    Since the beginning of life nature has been developing some remarkable solutions to the problem of creating reliable systems that can operate under difficult environmental and fault conditions. Yet, no matter how sophisticated our systems are, we are still unable to match the high degree of reliability that biological organisms posses. Since the early '90s attempts have been made to adapt biological properties and processes to the design of electronic systems but the results have always been unduly complex.This paper, proposes a novel model using a radically new approach to construct highly reliable electronic systems with online fault repair properties. It uses the characteristics and behaviour of unicellular bacteria and bacterial communities to achieve this. The result is a configurable bio-inspired cellular array architecture that, with built-in self-diagnostic and self-repair properties, can implement any application specific electronic system but is particularly suited for safety critical environments, such as space.

  11. How to Make Reliable, Washable, and Wearable Textronic Devices

    PubMed Central

    Tao, Xuyuan; Koncar, Vladan; Huang, Tzu-Hao; Shen, Chien-Lung; Ko, Ya-Chi; Jou, Gwo-Tsuen

    2017-01-01

    In this paper, the washability of wearable textronic (textile-electronic) devices has been studied. Two different approaches aiming at designing, producing, and testing robust washable and reliable smart textile systems are presented. The common point of the two approaches is the use of flexible conductive PCB in order to interface the miniaturized rigid (traditional) electronic devices to conductive threads and tracks within the textile flexible fabric and to connect them to antenna, textile electrodes, sensors, actuators, etc. The first approach consists in the use of TPU films (thermoplastic polyurethane) that are deposited by the press under controlled temperature and pressure parameters in order to protect the conductive thread and electrical contacts. The washability of conductive threads and contact resistances between flexible PCB and conductive threads are tested. The second approach is focused on the protection of the whole system—composed of a rigid electronic device, flexible PCB, and textile substrate—by a barrier made of latex. Three types of prototypes were realized and washed. Their reliabilities are studied. PMID:28338607

  12. The relationship between past caries experience and tooth color determined by an opto-electronic method.

    PubMed

    Kerosuo, E; Kolehmainen, L

    1982-01-01

    The susceptibility of a tooth to dental caries has been proposed to depend on tooth color. So far there has, however, been no reliable method for tooth color determination. The aims of this study were to evaluate the reliability of an opto-electronic method and to examine the relationship between tooth color and past caries experience. The color of upper right central incisors of 64 school-children was determined using an opto-electronic tri-stimulus color comparator. The intra- and interexaminer reliability of the method was evaluated in vitro and in vivo being 85% and 83%, respectively. To assess the past caries experience the DMFS-index was calculated. Oral hygiene and dietary habits were also assessed. No significant difference in DMFS scores was obtained between the 'white teeth' group and the 'yellow teeth' group. The conclusion is, that the practical importance of possible colorrelated differences in caries resistance is negligible due to the multifaceted nature of dental caries.

  13. Mechanical and Electronic Approaches to Improve the Sensitivity of Microcantilever Sensors

    PubMed Central

    Mutyala, Madhu Santosh Ku; Bandhanadham, Deepika; Pan, Liu; Pendyala, Vijaya Rohini; Ji, Hai-Feng

    2010-01-01

    Advances in the field of Micro Electro Mechanical Systems (MEMS) and their uses now offer unique opportunities in the design of ultrasensitive analytical tools. The analytical community continues to search for cost-effective, reliable, and even portable analytical techniques that can give reliable and fast response results for a variety of chemicals and biomolecules. Microcantilevers (MCLs) have emerged as a unique platform for label-free biosensor or bioassay. Several electronic designs, including piezoresistive, piezoelectric, and capacitive approaches, have been applied to measure the bending or frequency change of the MCLs upon exposure to chemicals. This review summarizes mechanical, fabrication, and electronics approaches to increase the sensitivity of microcantilever (MCL) sensors. PMID:20975987

  14. A systematic review of reliability and objective criterion-related validity of physical activity questionnaires.

    PubMed

    Helmerhorst, Hendrik J F; Brage, Søren; Warren, Janet; Besson, Herve; Ekelund, Ulf

    2012-08-31

    Physical inactivity is one of the four leading risk factors for global mortality. Accurate measurement of physical activity (PA) and in particular by physical activity questionnaires (PAQs) remains a challenge. The aim of this paper is to provide an updated systematic review of the reliability and validity characteristics of existing and more recently developed PAQs and to quantitatively compare the performance between existing and newly developed PAQs.A literature search of electronic databases was performed for studies assessing reliability and validity data of PAQs using an objective criterion measurement of PA between January 1997 and December 2011. Articles meeting the inclusion criteria were screened and data were extracted to provide a systematic overview of measurement properties. Due to differences in reported outcomes and criterion methods a quantitative meta-analysis was not possible.In total, 31 studies testing 34 newly developed PAQs, and 65 studies examining 96 existing PAQs were included. Very few PAQs showed good results on both reliability and validity. Median reliability correlation coefficients were 0.62-0.71 for existing, and 0.74-0.76 for new PAQs. Median validity coefficients ranged from 0.30-0.39 for existing, and from 0.25-0.41 for new PAQs.Although the majority of PAQs appear to have acceptable reliability, the validity is moderate at best. Newly developed PAQs do not appear to perform substantially better than existing PAQs in terms of reliability and validity. Future PAQ studies should include measures of absolute validity and the error structure of the instrument.

  15. A systematic review of reliability and objective criterion-related validity of physical activity questionnaires

    PubMed Central

    2012-01-01

    Physical inactivity is one of the four leading risk factors for global mortality. Accurate measurement of physical activity (PA) and in particular by physical activity questionnaires (PAQs) remains a challenge. The aim of this paper is to provide an updated systematic review of the reliability and validity characteristics of existing and more recently developed PAQs and to quantitatively compare the performance between existing and newly developed PAQs. A literature search of electronic databases was performed for studies assessing reliability and validity data of PAQs using an objective criterion measurement of PA between January 1997 and December 2011. Articles meeting the inclusion criteria were screened and data were extracted to provide a systematic overview of measurement properties. Due to differences in reported outcomes and criterion methods a quantitative meta-analysis was not possible. In total, 31 studies testing 34 newly developed PAQs, and 65 studies examining 96 existing PAQs were included. Very few PAQs showed good results on both reliability and validity. Median reliability correlation coefficients were 0.62–0.71 for existing, and 0.74–0.76 for new PAQs. Median validity coefficients ranged from 0.30–0.39 for existing, and from 0.25–0.41 for new PAQs. Although the majority of PAQs appear to have acceptable reliability, the validity is moderate at best. Newly developed PAQs do not appear to perform substantially better than existing PAQs in terms of reliability and validity. Future PAQ studies should include measures of absolute validity and the error structure of the instrument. PMID:22938557

  16. A new electronic meter for measuring herbage yield

    Treesearch

    Donald L. Neal; Lee R. Neal

    1965-01-01

    A new electronic instrument, called the Heterodyne Vegetation Meter to measure herbage yield and utilization was built and tested. The instrument proved to be reliable and rapid. Further testing will be conducted.

  17. The extended Lennard-Jones potential energy function: A simpler model for direct-potential-fit analysis

    NASA Astrophysics Data System (ADS)

    Hajigeorgiou, Photos G.

    2016-12-01

    An analytical model for the diatomic potential energy function that was recently tested as a universal function (Hajigeorgiou, 2010) has been further modified and tested as a suitable model for direct-potential-fit analysis. Applications are presented for the ground electronic states of three diatomic molecules: oxygen, carbon monoxide, and hydrogen fluoride. The adjustable parameters of the extended Lennard-Jones potential model are determined through nonlinear regression by fits to calculated rovibrational energy term values or experimental spectroscopic line positions. The model is shown to lead to reliable, compact and simple representations for the potential energy functions of these systems and could therefore be classified as a suitable and attractive model for direct-potential-fit analysis.

  18. Different Approaches for Ensuring Performance/Reliability of Plastic Encapsulated Microcircuits (PEMs) in Space Applications

    NASA Technical Reports Server (NTRS)

    Gerke, R. David; Sandor, Mike; Agarwal, Shri; Moor, Andrew F.; Cooper, Kim A.

    2000-01-01

    Engineers within the commercial and aerospace industries are using trade-off and risk analysis to aid in reducing spacecraft system cost while increasing performance and maintaining high reliability. In many cases, Commercial Off-The-Shelf (COTS) components, which include Plastic Encapsulated Microcircuits (PEMs), are candidate packaging technologies for spacecrafts due to their lower cost, lower weight and enhanced functionality. Establishing and implementing a parts program that effectively and reliably makes use of these potentially less reliable, but state-of-the-art devices, has become a significant portion of the job for the parts engineer. Assembling a reliable high performance electronic system, which includes COTS components, requires that the end user assume a risk. To minimize the risk involved, companies have developed methodologies by which they use accelerated stress testing to assess the product and reduce the risk involved to the total system. Currently, there are no industry standard procedures for accomplishing this risk mitigation. This paper will present the approaches for reducing the risk of using PEMs devices in space flight systems as developed by two independent Laboratories. The JPL procedure involves primarily a tailored screening with accelerated stress philosophy while the APL procedure is primarily, a lot qualification procedure. Both Laboratories successfully have reduced the risk of using the particular devices for their respective systems and mission requirements.

  19. Morphometric synaptology of a whole neuron profile using a semiautomatic interactive computer system.

    PubMed

    Saito, K; Niki, K

    1983-07-01

    We propose a new method of dealing with morphometric synaptology that processes all synapses and boutons around the HRP marked neuron on a large composite electron micrograph, rather than a qualitative or a piecemeal quantitative study of a particular synapse and/or bouton that is not positioned on the surface of the neuron. This approach requires the development of both neuroanatomical procedures, by which a specific whole neuronal profile is identified, and valuable specialized tools, which support the collection and analysis of a great volume of morphometric data from composite electron micrographs, in order to reduce the burden of the morphologist. The present report is also concerned with the total and reliable semi-automatic interactive computer system for gathering and analyzing morphometric data that has been under development in our laboratory. A morphologist performs the pattern recognition portion by using a large-sized tablet digitizer and a menu-sheet command, and the system registers the various morphometric values of many different neurons and performs statistical analysis. Some examples of morphometric measurements and analysis show the usefulness and efficiency of the proposed system and method.

  20. All-inkjet-printed thin-film transistors: manufacturing process reliability by root cause analysis

    PubMed Central

    Sowade, Enrico; Ramon, Eloi; Mitra, Kalyan Yoti; Martínez-Domingo, Carme; Pedró, Marta; Pallarès, Jofre; Loffredo, Fausta; Villani, Fulvia; Gomes, Henrique L.; Terés, Lluís; Baumann, Reinhard R.

    2016-01-01

    We report on the detailed electrical investigation of all-inkjet-printed thin-film transistor (TFT) arrays focusing on TFT failures and their origins. The TFT arrays were manufactured on flexible polymer substrates in ambient condition without the need for cleanroom environment or inert atmosphere and at a maximum temperature of 150 °C. Alternative manufacturing processes for electronic devices such as inkjet printing suffer from lower accuracy compared to traditional microelectronic manufacturing methods. Furthermore, usually printing methods do not allow the manufacturing of electronic devices with high yield (high number of functional devices). In general, the manufacturing yield is much lower compared to the established conventional manufacturing methods based on lithography. Thus, the focus of this contribution is set on a comprehensive analysis of defective TFTs printed by inkjet technology. Based on root cause analysis, we present the defects by developing failure categories and discuss the reasons for the defects. This procedure identifies failure origins and allows the optimization of the manufacturing resulting finally to a yield improvement. PMID:27649784

  1. CMOS-Technology-Enabled Flexible and Stretchable Electronics for Internet of Everything Applications.

    PubMed

    Hussain, Aftab M; Hussain, Muhammad M

    2016-06-01

    Flexible and stretchable electronics can dramatically enhance the application of electronics for the emerging Internet of Everything applications where people, processes, data and devices will be integrated and connected, to augment quality of life. Using naturally flexible and stretchable polymeric substrates in combination with emerging organic and molecular materials, nanowires, nanoribbons, nanotubes, and 2D atomic crystal structured materials, significant progress has been made in the general area of such electronics. However, high volume manufacturing, reliability and performance per cost remain elusive goals for wide commercialization of these electronics. On the other hand, highly sophisticated but extremely reliable, batch-fabrication-capable and mature complementary metal oxide semiconductor (CMOS)-based technology has facilitated tremendous growth of today's digital world using thin-film-based electronics; in particular, bulk monocrystalline silicon (100) which is used in most of the electronics existing today. However, one fundamental challenge is that state-of-the-art CMOS electronics are physically rigid and brittle. Therefore, in this work, how CMOS-technology-enabled flexible and stretchable electronics can be developed is discussed, with particular focus on bulk monocrystalline silicon (100). A comprehensive information base to realistically devise an integration strategy by rational design of materials, devices and processes for Internet of Everything electronics is offered. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Characterization of Quantum Efficiency and Robustness of Cesium-Based Photocathodes

    DTIC Science & Technology

    2010-01-01

    photocathodes produce picosecond-pulsed, high- current electron beams for photoinjection applications like free electron lasers . In photoinjectors, a...pulsed drive laser incident on the photocathode causes photoemission of short, dense bunches of electrons, which are then accelerated into a...relativistic, high quality beam. Future free electron lasers demand reliable photocathodes with long-lived quantum efficiency at suitable drive laser

  3. Home care nurses' attitudes toward computers. A confirmatory factor analysis of the Stronge and Brodt instrument.

    PubMed

    Stricklin, Mary Lou; Bierer, S Beth; Struk, Cynthia

    2003-01-01

    Point-of-care technology for home care use will be the final step in enterprise-wide healthcare electronic communications. Successful implementation of home care point-of-care technology hinges upon nurses' attitudes toward point-of-care technology and its use in clinical practice. This study addresses the factors associated with home care nurses' attitudes using Stronge and Brodt's Nurse Attitudes Toward Computers instrument. In this study, the Nurses Attitudes Toward Computers instrument was administered to a convenience sample of 138 nurses employed by a large midwestern home care agency, with an 88% response rate. Confirmatory factor analysis corroborated the Nurses Attitudes Toward Computers' 3-dimensional factor structure for practicing nurses, which was labeled as nurses' work, security issues, and perceived barriers. Results from the confirmatory factor analysis also suggest that these 3 factors are internally correlated and represent multiple dimensions of a higher order construct labeled as nurses' attitudes toward computers. Additionally, two of these factors, nurses' work and perceived barriers, each appears to explain more variance in nurses' attitudes toward computers than security issues. Instrument reliability was high for the sample (.90), with subscale reliabilities ranging from 86 to 70.

  4. Methodology for Physics and Engineering of Reliable Products

    NASA Technical Reports Server (NTRS)

    Cornford, Steven L.; Gibbel, Mark

    1996-01-01

    Physics of failure approaches have gained wide spread acceptance within the electronic reliability community. These methodologies involve identifying root cause failure mechanisms, developing associated models, and utilizing these models to inprove time to market, lower development and build costs and higher reliability. The methodology outlined herein sets forth a process, based on integration of both physics and engineering principles, for achieving the same goals.

  5. In-Depth View of the Structure and Growth of SnO2 Nanowires and Nanobrushes.

    PubMed

    Stuckert, Erin P; Geiss, Roy H; Miller, Christopher J; Fisher, Ellen R

    2016-08-31

    Strategic application of an array of complementary imaging and diffraction techniques is critical to determine accurate structural information on nanomaterials, especially when also seeking to elucidate structure-property relationships and their effects on gas sensors. In this work, SnO2 nanowires and nanobrushes grown via chemical vapor deposition (CVD) displayed the same tetragonal SnO2 structure as revealed via powder X-ray diffraction bulk crystallinity data. Additional characterization using a range of electron microscopy imaging and diffraction techniques, however, revealed important structure and morphology distinctions between the nanomaterials. Tailoring scanning transmission electron microscopy (STEM) modes combined with transmission electron backscatter diffraction (t-EBSD) techniques afforded a more detailed view of the SnO2 nanostructures. Indeed, upon deeper analysis of individual wires and brushes, we discovered that, despite a similar bulk structure, wires and brushes grew with different crystal faces and lattice spacings. Had we not utilized multiple STEM diffraction modes in conjunction with t-EBSD, differences in orientation related to bristle density would have been overlooked. Thus, it is only through a methodical combination of several structural analysis techniques that precise structural information can be reliably obtained.

  6. Sweetener blend optimization by using mixture design methodology and the electronic tongue.

    PubMed

    Waldrop, Megan E; Ross, Carolyn F

    2014-09-01

    Utilizing more than one sweetener has been shown to be an effective way to substitute sucrose in food products. The objective of this study was to apply the augmented simplex-centroid mixture design for the optimization of acceptable sweetener blends using coconut sugar, agave, and stevia. Sweetener blends were evaluated in aqueous solutions and gluten-free granola bars by a trained panel and consumers (n = 60). Significant differences were found between sweetener mixtures in solutions by both panelists and consumers (P < 0.05). Taste profiles for the sweetener solutions were also generated using the electronic tongue. Most consumer and trained intensity ratings were highly correlated (R(2) ≥ 0.79) with the electronic tongue taste profile analysis. Granola bars were also found to be significantly different (P < 0.05), with consumers preferring coconut sugar mixtures. Using contour plots and desirability function analysis, an optimal sweetener combination was found for a granola bar formulation of 89.9% coconut sugar, 6.1% agave, and 4% stevia. These results indicate that a mixture design can be a reliable way to develop new sweetener blends for product development. © 2014 Institute of Food Technologists®

  7. Electronic Noses for Well-Being: Breath Analysis and Energy Expenditure

    PubMed Central

    Gardner, Julian W.; Vincent, Timothy A.

    2016-01-01

    The wealth of information concealed in a single human breath has been of interest for many years, promising not only disease detection, but also the monitoring of our general well-being. Recent developments in the fields of nano-sensor arrays and MEMS have enabled once bulky artificial olfactory sensor systems, or so-called “electronic noses”, to become smaller, lower power and portable devices. At the same time, wearable health monitoring devices are now available, although reliable breath sensing equipment is somewhat missing from the market of physical, rather than chemical sensor gadgets. In this article, we report on the unprecedented rise in healthcare problems caused by an increasingly overweight population. We first review recently-developed electronic noses for the detection of diseases by the analysis of basic volatile organic compounds (VOCs). Then, we discuss the primary cause of obesity from over eating and the high calorific content of food. We present the need to measure our individual energy expenditure from our exhaled breath. Finally, we consider the future for handheld or wearable devices to measure energy expenditure; and the potential of these devices to revolutionize healthcare, both at home and in hospitals. PMID:27347946

  8. Micro-structural characterization of precipitation-synthesized fluorapatite nano-material by transmission electron microscopy using different sample preparation techniques.

    PubMed

    Chinthaka Silva, G W; Ma, Longzhou; Hemmers, Oliver; Lindle, Dennis

    2008-01-01

    Fluorapatite is a naturally occurring mineral of the apatite group and it is well known for its high physical and chemical stability. There is a recent interest in this ceramic to be used as a radioactive waste form material due to its intriguing chemical and physical properties. In this study, the nano-sized fluorapatite particles were synthesized using a precipitation method and the material was characterized using X-ray diffraction (XRD) and transmission electron microscopy (TEM). Two well-known methods, called solution-drop and the microtome cutting, were used to prepare the sample for TEM analysis. It was found that the microtome cutting technique is advantageous for examining the particle shape and cross-sectional morphology as well as for obtaining ultra-thin samples. However, this method introduces artifacts and strong background contrast for high-resolution transmission electron microscopy (HRTEM) observation. On the other hand, phase image simulations showed that the solution-drop method is reliable and stable for HRTEM analysis. Therefore, in order to comprehensively analyze the microstructure and morphology of the nano-material, it is necessary to combine both solution-drop and microtome cutting techniques for TEM sample preparation.

  9. Probing the Locality of Excited States with Linear Algebra.

    PubMed

    Etienne, Thibaud

    2015-04-14

    This article reports a novel theoretical approach related to the analysis of molecular excited states. The strategy introduced here involves gathering two pieces of physical information, coming from Hilbert and direct space operations, into a general, unique quantum mechanical descriptor of electronic transitions' locality. Moreover, the projection of Hilbert and direct space-derived indices in an Argand plane delivers a straightforward way to visually probe the ability of a dye to undergo a long- or short-range charge-transfer. This information can be applied, for instance, to the analysis of the electronic response of families of dyes to light absorption by unveiling the trend of a given push-pull chromophore to increase the electronic cloud polarization magnitude of its main transition with respect to the size extension of its conjugated spacer. We finally demonstrate that all the quantities reported in this article can be reliably approximated by a linear algebraic derivation, based on the contraction of detachment/attachment density matrices from canonical to atomic space. This alternative derivation has the remarkable advantage of a very low computational cost with respect to the previously used numerical integrations, making fast and accurate characterization of large molecular systems' excited states easily affordable.

  10. Technology review for electronically controlled braking systems

    DOT National Transportation Integrated Search

    1998-09-22

    Electronically Controlled Braking Systems (ECBS) offer many potential benefits to the trucking industry in the areas of safety, reliability, enhanced driver feedback, and maintainability. ECBS are being tested by a number of manufacturers. These syst...

  11. Reliability-Based Electronics Shielding Design Tools

    NASA Technical Reports Server (NTRS)

    Wilson, J. W.; O'Neill, P. J.; Zang, T. A.; Pandolf, J. E.; Tripathi, R. K.; Koontz, Steven L.; Boeder, P.; Reddell, B.; Pankop, C.

    2007-01-01

    Shielding design on large human-rated systems allows minimization of radiation impact on electronic systems. Shielding design tools require adequate methods for evaluation of design layouts, guiding qualification testing, and adequate follow-up on final design evaluation.

  12. Synthesizing cognition in neuromorphic electronic systems

    PubMed Central

    Neftci, Emre; Binas, Jonathan; Rutishauser, Ueli; Chicca, Elisabetta; Indiveri, Giacomo; Douglas, Rodney J.

    2013-01-01

    The quest to implement intelligent processing in electronic neuromorphic systems lacks methods for achieving reliable behavioral dynamics on substrates of inherently imprecise and noisy neurons. Here we report a solution to this problem that involves first mapping an unreliable hardware layer of spiking silicon neurons into an abstract computational layer composed of generic reliable subnetworks of model neurons and then composing the target behavioral dynamics as a “soft state machine” running on these reliable subnets. In the first step, the neural networks of the abstract layer are realized on the hardware substrate by mapping the neuron circuit bias voltages to the model parameters. This mapping is obtained by an automatic method in which the electronic circuit biases are calibrated against the model parameters by a series of population activity measurements. The abstract computational layer is formed by configuring neural networks as generic soft winner-take-all subnetworks that provide reliable processing by virtue of their active gain, signal restoration, and multistability. The necessary states and transitions of the desired high-level behavior are then easily embedded in the computational layer by introducing only sparse connections between some neurons of the various subnets. We demonstrate this synthesis method for a neuromorphic sensory agent that performs real-time context-dependent classification of motion patterns observed by a silicon retina. PMID:23878215

  13. Architecture for fiber-optic sensors and actuators in aircraft propulsion systems

    NASA Technical Reports Server (NTRS)

    Glomb, W. L., Jr.

    1990-01-01

    This paper describes a design for fiber-optic sensing and control in advanced aircraft Electronic Engine Control (EEC). The recommended architecture is an on-engine EEC which contains electro-optic interface circuits for fiber-optic sensors. Size and weight are reduced by multiplexing arrays of functionally similar sensors on a pairs of optical fibers to common electro-optical interfaces. The architecture contains interfaces to seven sensor groups. Nine distinct fiber-optic sensor types were found to provide the sensing functions. Analysis revealed no strong discriminator (except reliability of laser diodes and remote electronics) on which to base a selection of preferred common interface type. A hardware test program is recommended to assess the relative maturity of the technologies and to determine real performance in the engine environment.

  14. Feasibility, strategy, methodology, and analysis of probe measurements in plasma under high gas pressure

    NASA Astrophysics Data System (ADS)

    Demidov, V. I.; Koepke, M. E.; Kurlyandskaya, I. P.; Malkov, M. A.

    2018-02-01

    This paper reviews existing theories for interpreting probe measurements of electron distribution functions (EDF) at high gas pressure when collisions of electrons with atoms and/or molecules near the probe are pervasive. An explanation of whether or not the measurements are realizable and reliable, an enumeration of the most common sources of measurement error, and an outline of proper probe-experiment design elements that inherently limit or avoid error is presented. Additionally, we describe recent expanded plasma-condition compatibility for EDF measurement, including in applications of large wall probe plasma diagnostics. This summary of the authors’ experiences gained over decades of practicing and developing probe diagnostics is intended to inform, guide, suggest, and detail the advantages and disadvantages of probe application in plasma research.

  15. Research of obtaining TiO2 by sol-gel method using titanium isopropoxide TIP and tetra-n-butyl orthotitanate TNB

    NASA Astrophysics Data System (ADS)

    Gómez de Salazar, J. M.; Nutescu Duduman, C.; Juárez Gonzalez, M.; Palamarciuc, I.; Barrena Pérez, M. I.; Carcea, I.

    2016-08-01

    Titanium dioxide crystallises in three polymorphs: anatase, rutile and brookite. Rutile is most stable form of the TiO2 polymorphs. In this paper we concentrate on obtaining rutile and anatase, both used in various applications. The chosen method is sol-gel, which is a reliable method used for obtaining titanium oxides. We prepared titanium dioxide with using titanium isopropoxide (TIP) with chemical construction (C12H28O4Ti) and tetra-n-butyl orthotitanate (TNB) with chemical construction (C16H36O4Ti). The experiments were carried out in order to compare the results of the samples with similar reaction conditions, but with different precursors, thus concluding which precursor gives best results. Using different analysis techniques as X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM) and Thermogravimetric Analysis (TGA) we characterised the samples morphologically and structurally.

  16. Hybrid statistics-simulations based method for atom-counting from ADF STEM images.

    PubMed

    De Wael, Annelies; De Backer, Annick; Jones, Lewys; Nellist, Peter D; Van Aert, Sandra

    2017-06-01

    A hybrid statistics-simulations based method for atom-counting from annular dark field scanning transmission electron microscopy (ADF STEM) images of monotype crystalline nanostructures is presented. Different atom-counting methods already exist for model-like systems. However, the increasing relevance of radiation damage in the study of nanostructures demands a method that allows atom-counting from low dose images with a low signal-to-noise ratio. Therefore, the hybrid method directly includes prior knowledge from image simulations into the existing statistics-based method for atom-counting, and accounts in this manner for possible discrepancies between actual and simulated experimental conditions. It is shown by means of simulations and experiments that this hybrid method outperforms the statistics-based method, especially for low electron doses and small nanoparticles. The analysis of a simulated low dose image of a small nanoparticle suggests that this method allows for far more reliable quantitative analysis of beam-sensitive materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The Influence of Sn Orientation on the Electromigration of Idealized Lead-free Interconnects

    NASA Astrophysics Data System (ADS)

    Linares, Xioranny

    As conventional lead solders are being replaced by Pb-free solders in electronic devices, the reliability of solder joints in integrated circuits (ICs) has become a high concern. Due to the miniaturization of ICs and consequently solder joints, the current density through the solder interconnects has increased causing electrical damage known as electromigration. Electromigration, atomic and mass migration due to high electron currents, is one of the most urgent reliability issues delaying the implementation of Pb-free solder materials in electronic devices. The research on Pb-free solders has mainly focused on the qualitative understanding of failure by electromigration. There has been little progress however, on the quantitative analysis of electromigration because of the lack of available material parameters, such as the effective charge, (z*), the driving force for electromigration. The research herein uses idealized interconnects to measure the z* of electromigration of Cu in Sn-3.0Ag-0.5Cu (SAC305) alloy under different experimental conditions. Planar SAC 305 interconnects were sandwiched between two Cu pads and subject to uniaxial current. The crystallographic orientation of Sn in these samples were characterized with electron backscatter diffraction (EBSD) and wavelength dispersive spectroscopy (WDS) before and after electromigration testing. Results indicate that samples with the c-axis aligned perpendicular to current flow, polycrystalline, and those with a diffusion barrier on the cathode side all inhibit the growth of intermetallic compounds (IMC). The effective charge values of Cu in SAC 305 under the different conditions tested were quantified for the first time and included in this dissertation. The following research is expected to help verify and improve the electromigration model and identify the desirable conditions to inhibit damage by electromigration in Pb-free solder joints.

  18. Dual-angle, self-calibrating Thomson scattering measurements in RFX-MOD

    NASA Astrophysics Data System (ADS)

    Giudicotti, L.; Pasqualotto, R.; Fassina, A.

    2014-11-01

    In the multipoint Thomson scattering (TS) system of the RFX-MOD experiment the signals from a few spatial positions can be observed simultaneously under two different scattering angles. In addition the detection system uses optical multiplexing by signal delays in fiber optic cables of different length so that the two sets of TS signals can be observed by the same polychromator. Owing to the dependence of the TS spectrum on the scattering angle, it was then possible to implement self-calibrating TS measurements in which the electron temperature Te, the electron density ne and the relative calibration coefficients of spectral channels sensitivity Ci were simultaneously determined by a suitable analysis of the two sets of TS data collected at the two angles. The analysis has shown that, in spite of the small difference in the spectra obtained at the two angles, reliable values of the relative calibration coefficients can be determined by the analysis of good S/N dual-angle spectra recorded in a few tens of plasma shots. This analysis suggests that in RFX-MOD the calibration of the entire set of TS polychromators by means of the similar, dual-laser (Nd:YAG/Nd:YLF) TS technique, should be feasible.

  19. Development of a new multimedia instrument to measure cancer-specific quality of life in Portuguese-speaking patients with varying literacy skills.

    PubMed

    Paiva, Carlos Eduardo; Siquelli, Felipe Augusto Ferreira; Zaia, Gabriela Rossi; de Andrade, Diocésio Alves Pinto; Borges, Marcos Aristoteles; Jácome, Alexandre A; Giroldo, Gisele Augusta Sousa Nascimento; Santos, Henrique Amorim; Hahn, Elizabeth A; Uemura, Gilberto; Paiva, Bianca Sakamoto Ribeiro

    2016-01-01

    To develop and validate a new multimedia instrument to measure health-related quality of life (HRQOL) in Portuguese-speaking patients with cancer. A mixed-methods study conducted in a large Brazilian Cancer Hospital. The instrument was developed along the following sequential phases: identification of HRQOL issues through qualitative content analysis of individual interviews, evaluation of the most important items according to the patients, review of the literature, evaluation by an expert committee, and pretesting. In sequence, an exploratory factor analysis was conducted (pilot testing, n = 149) to reduce the number of items and to define domains and scores. The psychometric properties of the IQualiV-OG-21 were measured in a large multicentre Brazilian study (n = 323). A software containing multimedia resources were developed to facilitate self-administration of IQualiV-OG-21; its feasibility and patients' preferences ("paper and pencil" vs. software) were further tested (n = 54). An exploratory factor analysis reduced the 30-item instrument to 21 items. The IQualiV-OG-21 was divided into 6 domains: emotional, physical, existential, interpersonal relationships, functional and financial. The multicentre study confirmed that it was valid and reliable. The electronic multimedia instrument was easy to complete and acceptable to patients. Regarding preferences, 61.1 % of them preferred the electronic format in comparison with the paper and pencil format. The IQualiV-OG-21 is a new valid and reliable multimedia HRQOL instrument that is well-understood, even by patients with low literacy skills, and can be answered quickly. It is a useful new tool that can be translated and tested in other cultures and languages.

  20. Quality of Computationally Inferred Gene Ontology Annotations

    PubMed Central

    Škunca, Nives; Altenhoff, Adrian; Dessimoz, Christophe

    2012-01-01

    Gene Ontology (GO) has established itself as the undisputed standard for protein function annotation. Most annotations are inferred electronically, i.e. without individual curator supervision, but they are widely considered unreliable. At the same time, we crucially depend on those automated annotations, as most newly sequenced genomes are non-model organisms. Here, we introduce a methodology to systematically and quantitatively evaluate electronic annotations. By exploiting changes in successive releases of the UniProt Gene Ontology Annotation database, we assessed the quality of electronic annotations in terms of specificity, reliability, and coverage. Overall, we not only found that electronic annotations have significantly improved in recent years, but also that their reliability now rivals that of annotations inferred by curators when they use evidence other than experiments from primary literature. This work provides the means to identify the subset of electronic annotations that can be relied upon—an important outcome given that >98% of all annotations are inferred without direct curation. PMID:22693439

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yue; Reeves, Geoffrey D.; Cunningham, Gregory S.

    Our study demonstrates the feasibility and reliability of using observations from low Earth orbit (LEO) to forecast and nowcast relativistic electrons in the outer radiation belt. Furthermore, we first report a high cross-energy, cross-pitch-angle coherence discovered between the trapped MeV electrons and precipitating approximately hundreds (~100s) of keV electrons—observed by satellites with very different altitudes—with correlation coefficients as high as ≳ 0.85. We then tested the feasibility of applying linear prediction filters to LEO data to predict the arrival of new MeV electrons during geomagnetic storms, as well as their evolving distributions afterward, based on the coherence. Reliability of thesemore » predictive filters is quantified by the performance efficiency with values as high as 0.74 when driven merely by LEO observations (or up to 0.94 with the inclusion of in situ MeV electron measurements). Finally, a hypothesis based upon the wave-particle resonance theory is proposed to explain the coherence, and a first-principle electron tracing model yields supporting evidence.« less

  2. NASA Electronic Parts and Packaging (NEPP) Program - Update

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2010-01-01

    This slide presentation reviews the goals and mission of the NASA Electronic Parts and Packaging (NEPP) Program. The NEPP mission is to provide guidance to NASA for the selection and application of microelectronics technologies, to improve understanding of the risks related to the use of these technologies in the space environment and to ensure that appropriate research is performed to meet NASA mission assurance needs. The program has been supporting NASA for over 20 years. The focus is on the reliability aspects of electronic devices. In this work the program also supports the electronics industry. There are several areas that the program is involved in: Memories, systems on a chip (SOCs), data conversion devices, power MOSFETS, power converters, scaled CMOS, capacitors, linear devices, fiber optics, and other electronics such as sensors, cryogenic and SiGe that are used in space systems. Each of these area are reviewed with the work that is being done in reliability and effects of radiation on these technologies.

  3. Improved Reliability of SiC Pressure Sensors for Long Term High Temperature Applications

    NASA Technical Reports Server (NTRS)

    Okojie, R. S.; Nguyen, V.; Savrun, E.; Lukco, D.

    2011-01-01

    We report advancement in the reliability of silicon carbide pressure sensors operating at 600 C for extended periods. The large temporal drifts in zero pressure offset voltage at 600 C observed previously were significantly suppressed to allow improved reliable operation. This improvement was the result of further enhancement of the electrical and mechanical integrity of the bondpad/contact metallization, and the introduction of studded bump bonding on the pad. The stud bump contact promoted strong adhesion between the Au bond pad and the Au die-attach. The changes in the zero offset voltage and bridge resistance over time at temperature were explained by the microstructure and phase changes within the contact metallization, that were analyzed with Auger electron spectroscopy (AES) and field emission scanning electron microscopy (FE-SEM).

  4. Pertinent parameters in photo-generation of electrons: Comparative study of anatase-based nano-TiO2 suspensions.

    PubMed

    Martel, D; Guerra, A; Turek, P; Weiss, J; Vileno, B

    2016-04-01

    In the field of solar fuel cells, the development of efficient photo-converting semiconductors remains a major challenge. A rational analysis of experimental photocatalytic results obtained with material in colloïdal suspensions is needed to access fundamental knowledge required to improve the design and properties of new materials. In this study, a simple system electron donor/nano-TiO2 is considered and examined via spin scavenging electron paramagnetic resonance as well as a panel of analytical techniques (composition, optical spectroscopy and dynamic light scattering) for selected type of nano-TiO2. Independent variables (pH, electron donor concentration and TiO2 amount) have been varied and interdependent variables (aggregate size, aggregate surface vs. volume and acid/base groups distribution) are discussed. This work shows that reliable understanding involves thoughtful combination of interdependent parameters, whereas the specific surface area seems not a pertinent parameter. The conclusion emphasizes the difficulty to identify the key features of the mechanisms governing photocatalytic properties in nano-TiO2. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. First-principles study of Al2Sm intermetallic compound on structural, mechanical properties and electronic structure

    NASA Astrophysics Data System (ADS)

    Lin, Jingwu; Wang, Lei; Hu, Zhi; Li, Xiao; Yan, Hong

    2017-02-01

    The structural, thermodynamic, mechanical and electronic properties of cubic Al2Sm intermetallic compound are investigated by the first-principles method on the basis of density functional theory. In light of the strong on-site Coulomb repulsion between the highly localized 4f electrons of Sm atoms, the local spin density approximation approach paired with additional Hubbard terms is employed to achieve appropriate results. Moreover, to examine the reliability of this study, the experimental value of lattice parameter is procured from the analysis of the TEM image and diffraction pattern of Al2Sm phase in the AZ31 alloy to verify the authenticity of the results originated from the computational method. The value of cohesive energy reveals Al2Sm to be a stable in absolute zero Kelvin. According to the stability criteria, the subject of this work is mechanically stable. Afterward, elastic moduli are deduced by performing Voigt-Reuss-Hill approximation. Furthermore, elastic anisotropy and anisotropy of sound velocity are discussed. Finally, the calculation of electronic density of states is implemented to explore the underlying mechanism of structural stability.

  6. Cryogenic coherent X-ray diffraction imaging of biological samples at SACLA: a correlative approach with cryo-electron and light microscopy.

    PubMed

    Takayama, Yuki; Yonekura, Koji

    2016-03-01

    Coherent X-ray diffraction imaging at cryogenic temperature (cryo-CXDI) allows the analysis of internal structures of unstained, non-crystalline, whole biological samples in micrometre to sub-micrometre dimensions. Targets include cells and cell organelles. This approach involves preparing frozen-hydrated samples under controlled humidity, transferring the samples to a cryo-stage inside a vacuum chamber of a diffractometer, and then exposing the samples to coherent X-rays. Since 2012, cryo-coherent diffraction imaging (CDI) experiments have been carried out with the X-ray free-electron laser (XFEL) at the SPring-8 Ångstrom Compact free-electron LAser (SACLA) facility in Japan. Complementary use of cryo-electron microscopy and/or light microscopy is highly beneficial for both pre-checking samples and studying the integrity or nature of the sample. This article reports the authors' experience in cryo-XFEL-CDI of biological cells and organelles at SACLA, and describes an attempt towards reliable and higher-resolution reconstructions, including signal enhancement with strong scatterers and Patterson-search phasing.

  7. Two-dimensional hybrid Monte Carlo–fluid modelling of dc glow discharges: Comparison with fluid models, reliability, and accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eylenceoğlu, E.; Rafatov, I., E-mail: rafatov@metu.edu.tr; Kudryavtsev, A. A.

    2015-01-15

    Two-dimensional hybrid Monte Carlo–fluid numerical code is developed and applied to model the dc glow discharge. The model is based on the separation of electrons into two parts: the low energetic (slow) and high energetic (fast) electron groups. Ions and slow electrons are described within the fluid model using the drift-diffusion approximation for particle fluxes. Fast electrons, represented by suitable number of super particles emitted from the cathode, are responsible for ionization processes in the discharge volume, which are simulated by the Monte Carlo collision method. Electrostatic field is obtained from the solution of Poisson equation. The test calculations weremore » carried out for an argon plasma. Main properties of the glow discharge are considered. Current-voltage curves, electric field reversal phenomenon, and the vortex current formation are developed and discussed. The results are compared to those obtained from the simple and extended fluid models. Contrary to reports in the literature, the analysis does not reveal significant advantages of existing hybrid methods over the extended fluid model.« less

  8. Drive and protection circuit for converter module of cascaded H-bridge STATCOM

    NASA Astrophysics Data System (ADS)

    Wang, Xuan; Yuan, Hongliang; Wang, Xiaoxing; Wang, Shuai; Fu, Yongsheng

    2018-04-01

    Drive and protection circuit is an important part of power electronics, which is related to safe and stable operation issues in the power electronics. The drive and protection circuit is designed for the cascaded H-bridge STATCOM. This circuit can realize flexible dead-time setting, operation status self-detection, fault priority protection and detailed fault status uploading. It can help to improve the reliability of STATCOM's operation. Finally, the proposed circuit is tested and analyzed by power electronic simulation software PSPICE (Simulation Program with IC Emphasis) and a series of experiments. Further studies showed that the proposed circuit can realize drive and control of H-bridge circuit, meanwhile it also can realize fast processing faults and have advantage of high reliability.

  9. Determination of nitrogen in coal macerals using electron microprobe technique-experimental procedure

    USGS Publications Warehouse

    Mastalerz, Maria; Gurba, L.W.

    2001-01-01

    This paper discusses nitrogen determination with the Cameca SX50 electron microprobe using PCO as an analyzing crystal. A set of conditions using differing accelerating voltages, beam currents, beam sizes, and counting times were tested to determine parameters that would give the most reliable nitrogen determination. The results suggest that, for the instrumentation used, 10 kV, current 20 nA, and a counting time of 20 s provides the most reliable nitrogen determination, with a much lower detection limit than the typical concentration of this element in coal. The study demonstrates that the electron microprobe technique can be used to determine the nitrogen content of coal macerals successfully and accurately. ?? 2001 Elsevier Science B.V. All rights reserved.

  10. Understanding the Reliability of Solder Joints Used in Advanced Structural and Electronics Applications: Part 2 - Reliability Performance.

    DOE PAGES

    Vianco, Paul T.

    2017-03-01

    Whether structural or electronic, all solder joints must provide the necessary level of reliability for the application. The Part 1 report examined the effects of filler metal properties and the soldering process on joint reliability. Filler metal solderability and mechanical properties, as well as the extents of base material dissolution and interface reaction that occur during the soldering process, were shown to affect reliability performance. The continuation of this discussion is presented in this Part 2 report, which highlights those factors that directly affect solder joint reliability. There is the growth of an intermetallic compound (IMC) reaction layer at themore » solder/base material interface by means of solid-state diffusion processes. In terms of mechanical response by the solder joint, fatigue remains as the foremost concern for long-term performance. Thermal mechanical fatigue (TMF), a form of low-cycle fatigue (LCF), occurs when temperature cycling is combined with mismatched values of the coefficient of thermal expansion (CTE) between materials comprising the solder joint “system.” Vibration environments give rise to high-cycle fatigue (HCF) degradation. Although accelerated aging studies provide valuable empirical data, too many variants of filler metals, base materials, joint geometries, and service environments are forcing design engineers to embrace computational modeling to predict the long-term reliability of solder joints.« less

  11. Analysis of the EBT3 Gafchromic film irradiated with 6 MV photons and 6 MeV electrons using reflective mode scanners.

    PubMed

    Farah, Nicolas; Francis, Ziad; Abboud, Marie

    2014-09-01

    We explore in our study the effects of electrons and X-rays irradiations on the newest version of the Gafchromic EBT3 film. Experiments are performed using the Varian "TrueBeam 1.6" medical accelerator delivering 6 MV X-ray photons and 6 MeV electron beams as desired. The main interest is to compare the responses of EBT3 films exposed to two separate beams of electrons and photons, for radiation doses ranging up to 500 cGy. The analysis is done on a flatbed EPSON 10000 XL scanner and cross checked on a HP Scanjet 4850 scanner. Both scanners are used in reflection mode taking into account landscape and portrait scanning positions. After thorough verifications, the reflective scanning method can be used on EBT3 as an economic alternative to the transmission method which was also one of the goals of this study. A comparison is also done between single scan configuration including all samples in a single A4 (HP) or A3 (EPSON) format area and multiple scan procedure where each sample is scanned separately on its own. The images analyses are done using the ImageJ software. Results show significant influence of the scanning configuration but no significant differences between electron and photon irradiations for both single and multiple scan configurations. In conclusion, the film provides a reliable relative dose measurement method for electrons and photons irradiations in the medical field applications. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. NREL Joins Initiative to Boost Power Electronics Energy Efficiency and Job

    Science.gov Websites

    Electronics and Electric Machines team, which focuses on vehicle component research and development (R&D current silicon-based components in the next five years. The institute will bring partners together to power electronics thermal management and reliability R&D, NREL's research in this area focuses on

  13. Thick target bremsstrahlung spectra for 1.00-, 1.25-, and 1.40-Mev electrons

    USGS Publications Warehouse

    Miller, W.; Motz, J.W.; Cialella, C.

    1954-01-01

    The spectrum of radiation produced by 1.0-, 1.25-, and 1.40-Mev electrons incident on a thick tungsten target was measured at 0A????and 90A????with the incident beam by a method involving the magnetic analysis of Compton electrons. The effects of electron scattering and energy loss in the target preclude any simple interpretation of this data to yield a differential bremsstrahlung cross section. However, an estimate of the spectra to be expected at 0A????and 90A????was obtained by combining the Sauter expression for the bremsstrahlung cross section with the available information on electron scatter and energy loss in the target and backscatter from the target. The reliability of the estimate is limited because the Sauter formula was calculated by using the Born approximation, the electron scattering calculations are applicable to an infinite medium only, and the backscatter was estimated empirically from Bothe's experimental data which were obtained with lower energy electrons (370 kev). Furthermore electron energy straggling was neglected. Nevertheless, the predicted spectral shapes at 0A????and 90A????and the relative intensities at these two angles are in qualitative agreement with the measured values. The absolute magnitudes of the measured intensities at both angles are about a factor of two greater than the predicted values. ?? 1954 The American Physical Society.

  14. Operating Room Delays: Meaningful Use in Electronic Health Record.

    PubMed

    Van Winkle, Rachelle A; Champagne, Mary T; Gilman-Mays, Meri; Aucoin, Julia

    2016-06-01

    Perioperative areas are the most costly to operate and account for more than 40% of expenses. The high costs prompted one organization to analyze surgical delays through a retrospective review of their new electronic health record. Electronic health records have made it easier to access and aggregate clinical data; 2123 operating room cases were analyzed. Implementing a new electronic health record system is complex; inaccurate data and poor implementation can introduce new problems. Validating the electronic health record development processes determines the ease of use and the user interface, specifically related to user compliance with the intent of the electronic health record development. The revalidation process after implementation determines if the intent of the design was fulfilled and data can be meaningfully used. In this organization, the data fields completed through automation provided quantifiable, meaningful data. However, data fields completed by staff that required subjective decision making resulted in incomplete data nearly 24% of the time. The ease of use was further complicated by 490 permutations (combinations of delay types and reasons) that were built into the electronic health record. Operating room delay themes emerged notwithstanding the significant complexity of the electronic health record build; however, improved accuracy could improve meaningful data collection and a more accurate root cause analysis of operating room delays. Accurate and meaningful use of data affords a more reliable approach in quality, safety, and cost-effective initiatives.

  15. Evaluation of Advanced COTS Passive Devices for Extreme Temperature Operation

    NASA Technical Reports Server (NTRS)

    Patterson, Richard; Hammoud, Ahmad; Dones, Keishla R.

    2009-01-01

    Electronic sensors and circuits are often exposed to extreme temperatures in many of NASA deep space and planetary surface exploration missions. Electronics capable of operation in harsh environments would be beneficial as they simplify overall system design, relax thermal management constraints, and meet operational requirements. For example, cryogenic operation of electronic parts will improve reliability, increase energy density, and extend the operational lifetimes of space-based electronic systems. Similarly, electronic parts that are able to withstand and operate efficiently in high temperature environments will negate the need for thermal control elements and their associated structures, thereby reducing system size and weight, enhancing its reliability, improving its efficiency, and reducing cost. Passive devices play a critical role in the design of almost all electronic circuitry. To address the needs of systems for extreme temperature operation, some of the advanced and most recently introduced commercial-off-the-shelf (COTS) passive devices, which included resistors and capacitors, were examined for operation under a wide temperature regime. The types of resistors investigated included high temperature precision film, general purpose metal oxide, and wirewound.

  16. Forecasting and remote sensing outer belt relativistic electrons from low Earth orbit

    DOE PAGES

    Chen, Yue; Reeves, Geoffrey D.; Cunningham, Gregory S.; ...

    2016-02-15

    Our study demonstrates the feasibility and reliability of using observations from low Earth orbit (LEO) to forecast and nowcast relativistic electrons in the outer radiation belt. Furthermore, we first report a high cross-energy, cross-pitch-angle coherence discovered between the trapped MeV electrons and precipitating approximately hundreds (~100s) of keV electrons—observed by satellites with very different altitudes—with correlation coefficients as high as ≳ 0.85. We then tested the feasibility of applying linear prediction filters to LEO data to predict the arrival of new MeV electrons during geomagnetic storms, as well as their evolving distributions afterward, based on the coherence. Reliability of thesemore » predictive filters is quantified by the performance efficiency with values as high as 0.74 when driven merely by LEO observations (or up to 0.94 with the inclusion of in situ MeV electron measurements). Finally, a hypothesis based upon the wave-particle resonance theory is proposed to explain the coherence, and a first-principle electron tracing model yields supporting evidence.« less

  17. Openness of patients' reporting with use of electronic records: psychiatric clinicians' views

    PubMed Central

    Blackford, Jennifer Urbano; Rosenbloom, S Trent; Seidel, Sandra; Clayton, Ellen Wright; Dilts, David M; Finder, Stuart G

    2010-01-01

    Objectives Improvements in electronic health record (EHR) system development will require an understanding of psychiatric clinicians' views on EHR system acceptability, including effects on psychotherapy communications, data-recording behaviors, data accessibility versus security and privacy, data quality and clarity, communications with medical colleagues, and stigma. Design Multidisciplinary development of a survey instrument targeting psychiatric clinicians who recently switched to EHR system use, focus group testing, data analysis, and data reliability testing. Measurements Survey of 120 university-based, outpatient mental health clinicians, with 56 (47%) responding, conducted 18 months after transition from a paper to an EHR system. Results Factor analysis gave nine item groupings that overlapped strongly with five a priori domains. Respondents both praised and criticized the EHR system. A strong majority (81%) felt that open therapeutic communications were preserved. Regarding data quality, content, and privacy, clinicians (63%) were less willing to record highly confidential information and disagreed (83%) with including their own psychiatric records among routinely accessed EHR systems. Limitations single time point; single academic medical center clinic setting; modest sample size; lack of prior instrument validation; survey conducted in 2005. Conclusions In an academic medical center clinic, the presence of electronic records was not seen as a dramatic impediment to therapeutic communications. Concerns regarding privacy and data security were significant, and may contribute to reluctances to adopt electronic records in other settings. Further study of clinicians' views and use patterns may be helpful in guiding development and deployment of electronic records systems. PMID:20064802

  18. Replacing ODCs in a Critical Hand Cleaning Manual Electronics Assembly Operation

    NASA Technical Reports Server (NTRS)

    Bonner, J. K.; Walton, Sharon

    1997-01-01

    The manufacture of high reliability electronics assemblies for spacecraft and ground support equipment still often involves manual assembly processes. In addition, rework and repair of critical assemblies aslo often entails manual assembly processes.

  19. Assessment of Safety Standards for Automotive Electronic Control Systems

    DOT National Transportation Integrated Search

    2016-06-01

    This report summarizes the results of a study that assessed and compared six industry and government safety standards relevant to the safety and reliability of automotive electronic control systems. These standards include ISO 26262 (Road Vehicles - ...

  20. H-aggregate analysis of P3HT thin films-Capability and limitation of photoluminescence and UV/Vis spectroscopy.

    PubMed

    Ehrenreich, Philipp; Birkhold, Susanne T; Zimmermann, Eugen; Hu, Hao; Kim, Kwang-Dae; Weickert, Jonas; Pfadler, Thomas; Schmidt-Mende, Lukas

    2016-09-01

    Polymer morphology and aggregation play an essential role for efficient charge carrier transport and charge separation in polymer-based electronic devices. It is a common method to apply the H-aggregate model to UV/Vis or photoluminescence spectra in order to analyze polymer aggregation. In this work we present strategies to obtain reliable and conclusive information on polymer aggregation and morphology based on the application of an H-aggregate analysis on UV/Vis and photoluminescence spectra. We demonstrate, with P3HT as model system, that thickness dependent reflection behavior can lead to misinterpretation of UV/Vis spectra within the H-aggregate model. Values for the exciton bandwidth can deviate by a factor of two for polymer thicknesses below 150 nm. In contrast, photoluminescence spectra are found to be a reliable basis for characterization of polymer aggregation due to their weaker dependence on the wavelength dependent refractive index of the polymer. We demonstrate this by studying the influence of surface characteristics on polymer aggregation for spin-coated thin-films that are commonly used in organic and hybrid solar cells.

  1. Degradation of Leakage Currents and Reliability Prediction for Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2016-01-01

    Two types of failures in solid tantalum capacitors, catastrophic and parametric, and their mechanisms are described. Analysis of voltage and temperature reliability acceleration factors reported in literature shows a wide spread of results and requires more investigation. In this work, leakage currents in two types of chip tantalum capacitors were monitored during highly accelerated life testing (HALT) at different temperatures and voltages. Distributions of degradation rates were approximated using a general log-linear Weibull model and yielded voltage acceleration constants B = 9.8 +/- 0.5 and 5.5. The activation energies were Ea = 1.65 eV and 1.42 eV. The model allows for conservative estimations of times to failure and was validated by long-term life test data. Parametric degradation and failures are reversible and can be annealed at high temperatures. The process is attributed to migration of charged oxygen vacancies that reduce the barrier height at the MnO2/Ta2O5 interface and increase injection of electrons from the MnO2 cathode. Analysis showed that the activation energy of the vacancies' migration is 1.1 eV.

  2. A peer-nomination assessment of electronic forms of aggression and victimization.

    PubMed

    Badaly, Daryaneh; Duong, Mylien T; Ross, Alexandra C; Schwartz, David

    2015-10-01

    The perpetration and receipt of electronic aggression have largely been assessed with self-report questionnaires. Using a sample of 573 adolescents, the current study compared the psychometric properties of a peer-nomination measure of electronic aggression and victimization to the more widely used self-report approach. Estimates of the reliability, stability, and concordance of peer- and self-report assessments were adequate, mirroring those from research on aggressive exchanges in school. Analyses of validity and utility revealed that peer-nominations, compared to self-reports, provide overlapping and distinct information on adolescents' social, emotional, and academic adjustment. Overall, these findings provide evidence that peer-nominations are a reliable, valid, and useful means for measuring electronic aggression and victimization. Future work will benefit from their incorporation into multi-method assessments. Copyright © 2015 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  3. Stretchable carbon nanotube charge-trap floating-gate memory and logic devices for wearable electronics.

    PubMed

    Son, Donghee; Koo, Ja Hoon; Song, Jun-Kyul; Kim, Jaemin; Lee, Mincheol; Shim, Hyung Joon; Park, Minjoon; Lee, Minbaek; Kim, Ji Hoon; Kim, Dae-Hyeong

    2015-05-26

    Electronics for wearable applications require soft, flexible, and stretchable materials and designs to overcome the mechanical mismatch between the human body and devices. A key requirement for such wearable electronics is reliable operation with high performance and robustness during various deformations induced by motions. Here, we present materials and device design strategies for the core elements of wearable electronics, such as transistors, charge-trap floating-gate memory units, and various logic gates, with stretchable form factors. The use of semiconducting carbon nanotube networks designed for integration with charge traps and ultrathin dielectric layers meets the performance requirements as well as reliability, proven by detailed material and electrical characterizations using statistics. Serpentine interconnections and neutral mechanical plane layouts further enhance the deformability required for skin-based systems. Repetitive stretching tests and studies in mechanics corroborate the validity of the current approaches.

  4. Development and testing of mobile technology for community park improvements: validity and reliability of the eCPAT application with youth.

    PubMed

    Besenyi, Gina M; Diehl, Paul; Schooley, Benjamin; Turner-McGrievy, Brie M; Wilcox, Sara; Stanis, Sonja A Wilhelm; Kaczynski, Andrew T

    2016-12-01

    Creation of mobile technology environmental audit tools can provide a more interactive way for youth to engage with communities and facilitate participation in health promotion efforts. This study describes the development and validity and reliability testing of an electronic version of the Community Park Audit Tool (eCPAT). eCPAT consists of 149 items and incorporates a variety of technology benefits. Criterion-related validity and inter-rater reliability were evaluated using data from 52 youth across 47 parks in Greenville County, SC. A large portion of items (>70 %) demonstrated either fair or moderate to perfect validity and reliability. All but six items demonstrated excellent percent agreement. The eCPAT app is a user-friendly tool that provides a comprehensive assessment of park environments. Given the proliferation of smartphones, tablets, and other electronic devices among both adolescents and adults, the eCPAT app has potential to be distributed and used widely for a variety of health promotion purposes.

  5. Ultrastructure Processing and Environmental Stability of Advanced Structural and Electronic Materials.

    DTIC Science & Technology

    1983-03-01

    network dissolution, electron beam simulated desorption, electron signal decay, oxidation, oxide layer , growth kinetics, silicon carbide, assivation...surface layers on silicate glasses are reviewed. A type IIIB glass surface is proposed. The mechanisms of hydrothermal attack of two phase lithia...method to make reliable lifetime predictions. Use of electron beam techniques is essential for understanding surface layers formed on glasses (Section III

  6. A reliability analysis tool for SpaceWire network

    NASA Astrophysics Data System (ADS)

    Zhou, Qiang; Zhu, Longjiang; Fei, Haidong; Wang, Xingyou

    2017-04-01

    A SpaceWire is a standard for on-board satellite networks as the basis for future data-handling architectures. It is becoming more and more popular in space applications due to its technical advantages, including reliability, low power and fault protection, etc. High reliability is the vital issue for spacecraft. Therefore, it is very important to analyze and improve the reliability performance of the SpaceWire network. This paper deals with the problem of reliability modeling and analysis with SpaceWire network. According to the function division of distributed network, a reliability analysis method based on a task is proposed, the reliability analysis of every task can lead to the system reliability matrix, the reliability result of the network system can be deduced by integrating these entire reliability indexes in the matrix. With the method, we develop a reliability analysis tool for SpaceWire Network based on VC, where the computation schemes for reliability matrix and the multi-path-task reliability are also implemented. By using this tool, we analyze several cases on typical architectures. And the analytic results indicate that redundancy architecture has better reliability performance than basic one. In practical, the dual redundancy scheme has been adopted for some key unit, to improve the reliability index of the system or task. Finally, this reliability analysis tool will has a directive influence on both task division and topology selection in the phase of SpaceWire network system design.

  7. High-fidelity large area nano-patterning of silicon with femtosecond light sheet

    NASA Astrophysics Data System (ADS)

    Sidhu, Mehra S.; Munjal, Pooja; Singh, Kamal P.

    2018-01-01

    We employ a femtosecond light sheet generated by a cylindrical lens to rapidly produce high-fidelity nano-structures over large area on silicon surface. The Fourier analysis of electron microscopy images of the laser-induced surface structures reveals sharp peaks indicating good homogeneity. We observed an emergence of second-order spatial periodicity on increasing the scan speed. Our reliable approach may rapidly nano-pattern curved solid surfaces and tiny objects for diverse potential applications in optical devices, structural coloring, plasmonic substrates and in high-harmonic generation.

  8. Advanced Relay Design and Technology for Energy-Efficient Electronics

    DTIC Science & Technology

    2011-07-07

    Estimates and Unique Failure Mechanisms of the Digital Micromirror Device (DMD),” in Proceedings of the IEEE Annual International Reliability Physics...Symposium (IRPS 󈨦), pp. 9-16, March 1998. [18] A. B. Sontheimer, “Digital Micromirror Device (DMD) Hinge Memory Lifetime Reliability Modeling,” in...Mechanisms of the Digital Micromirror Device (DMD),” in Proceedings of the IEEE Annual International Reliability Physics Symposium (IRPS 󈨦), pp. 9-16

  9. The Trojan Lifetime Champions Health Survey: development, validity, and reliability.

    PubMed

    Sorenson, Shawn C; Romano, Russell; Scholefield, Robin M; Schroeder, E Todd; Azen, Stanley P; Salem, George J

    2015-04-01

    Self-report questionnaires are an important method of evaluating lifespan health, exercise, and health-related quality of life (HRQL) outcomes among elite, competitive athletes. Few instruments, however, have undergone formal characterization of their psychometric properties within this population. To evaluate the validity and reliability of a novel health and exercise questionnaire, the Trojan Lifetime Champions (TLC) Health Survey. Descriptive laboratory study. A large National Collegiate Athletic Association Division I university. A total of 63 university alumni (age range, 24 to 84 years), including former varsity collegiate athletes and a control group of nonathletes. Participants completed the TLC Health Survey twice at a mean interval of 23 days with randomization to the paper or electronic version of the instrument. Content validity, feasibility of administration, test-retest reliability, parallel-form reliability between paper and electronic forms, and estimates of systematic and typical error versus differences of clinical interest were assessed across a broad range of health, exercise, and HRQL measures. Correlation coefficients, including intraclass correlation coefficients (ICCs) for continuous variables and κ agreement statistics for ordinal variables, for test-retest reliability averaged 0.86, 0.90, 0.80, and 0.74 for HRQL, lifetime health, recent health, and exercise variables, respectively. Correlation coefficients, again ICCs and κ, for parallel-form reliability (ie, equivalence) between paper and electronic versions averaged 0.90, 0.85, 0.85, and 0.81 for HRQL, lifetime health, recent health, and exercise variables, respectively. Typical measurement error was less than the a priori thresholds of clinical interest, and we found minimal evidence of systematic test-retest error. We found strong evidence of content validity, convergent construct validity with the Short-Form 12 Version 2 HRQL instrument, and feasibility of administration in an elite, competitive athletic population. These data suggest that the TLC Health Survey is a valid and reliable instrument for assessing lifetime and recent health, exercise, and HRQL, among elite competitive athletes. Generalizability of the instrument may be enhanced by additional, larger-scale studies in diverse populations.

  10. Comparison of four methods of surface roughness assessment of corneal stromal bed after lamellar cutting

    PubMed Central

    Jumelle, Clotilde; Hamri, Alina; Egaud, Gregory; Mauclair, Cyril; Reynaud, Stephanie; Dumas, Virginie; Pereira, Sandrine; Garcin, Thibaud; Gain, Philippe; Thuret, Gilles

    2017-01-01

    Corneal lamellar cutting with a blade or femtosecond laser (FSL) is commonly used during refractive surgery and corneal grafts. Surface roughness of the cutting plane influences postoperative visual acuity but is difficult to assess reliably. For the first time, we compared chromatic confocal microscopy (CCM) with scanning electron microscopy, atomic force microscopy (AFM) and focus-variation microscopy (FVM) to characterize surfaces of variable roughness after FSL cutting. The small area allowed by AFM hinders conclusive roughness analysis, especially with irregular cuts. FVM does not always differentiate between smooth and rough surfaces. Finally, CCM allows analysis of large surfaces and differentiates between surface states. PMID:29188095

  11. TED analysis of the Si(113) surface structure

    NASA Astrophysics Data System (ADS)

    Suzuki, T.; Minoda, H.; Tanishiro, Y.; Yagi, K.

    1999-09-01

    We carried out a TED (transmission electron diffraction) analysis of the Si(113) surface structure. The TED patterns taken at room temperature showed reflections due to the 3×2 reconstructed structure. The TED pattern indicated that a glide plane parallel to the <332> direction suggested in some models is excluded. We calculated the R-factors (reliability factors) for six surface structure models proposed previously. All structure models with energy-optimized atomic positions have large R-factors. After revision of the atomic positions, the R-factors of all the structure models decreased below 0.3, and the revised version of Dabrowski's 3×2 model has the smallest R-factor of 0.17.

  12. Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing

    NASA Technical Reports Server (NTRS)

    Bhattacharya, Pallab

    2001-01-01

    Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.

  13. Laser Welding in Electronic Packaging

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The laser has proven its worth in numerous high reliability electronic packaging applications ranging from medical to missile electronics. In particular, the pulsed YAG laser is an extremely flexible and versatile too] capable of hermetically sealing microelectronics packages containing sensitive components without damaging them. This paper presents an overview of details that must be considered for successful use of laser welding when addressing electronic package sealing. These include; metallurgical considerations such as alloy and plating selection, weld joint configuration, design of optics, use of protective gases and control of thermal distortions. The primary limitations on use of laser welding electronic for packaging applications are economic ones. The laser itself is a relatively costly device when compared to competing welding equipment. Further, the cost of consumables and repairs can be significant. These facts have relegated laser welding to use only where it presents a distinct quality or reliability advantages over other techniques of electronic package sealing. Because of the unique noncontact and low heat inputs characteristics of laser welding, it is an ideal candidate for sealing electronic packages containing MEMS devices (microelectromechanical systems). This paper addresses how the unique advantages of the pulsed YAG laser can be used to simplify MEMS packaging and deliver a product of improved quality.

  14. Validation of the Chinese version of functional assessment of anorexia-cachexia therapy (FAACT) scale for measuring quality of life in cancer patients with cachexia.

    PubMed

    Zhou, Ting; Yang, Kaixiang; Thapa, Sudip; Fu, Qiang; Jiang, Yongsheng; Yu, Shiying

    2017-04-01

    The assessment of quality of life (QOL) is an important part of cachexia management for cancer patients. Functional assessment of anorexia-cachexia therapy (FAACT), a specific QOL instrument for cachexia patients, has not been validated in Chinese population. The aim of this study was to validate the FAACT scale in Chinese cancer patients for its future use. Eligible cancer patients were included in our study. Patients' demographic and clinical characteristics were collected from the electronic medical records. Patients were asked to complete the Chinese version of FAACT scale and the MD Anderson symptom inventory (MDASI), and then the reliability and validity were analyzed. A total of 285 patients were enrolled in our study, data of 241 patients were evaluated. Coefficients of Cronbach's alpha, test-retest and split-half analyses were all greater than 0.8, which indicated an excellent reliability for FAACT scale. In item-subscale correlation analysis and factor analysis, good construct validity for FAACT scale was found. The correlation between FAACT and MDASI interference subscale showed reasonable criterion-related validity, and for further clinical validation, the FAACT scale showed excellent discriminative validity for distinguishing patients in different cachexia status and in different performance status. The Chinese version of FAACT scale has good reliability and validity and is suitable for measuring QOL of cachexia patients in Chinese population.

  15. SABRE: a bio-inspired fault-tolerant electronic architecture.

    PubMed

    Bremner, P; Liu, Y; Samie, M; Dragffy, G; Pipe, A G; Tempesti, G; Timmis, J; Tyrrell, A M

    2013-03-01

    As electronic devices become increasingly complex, ensuring their reliable, fault-free operation is becoming correspondingly more challenging. It can be observed that, in spite of their complexity, biological systems are highly reliable and fault tolerant. Hence, we are motivated to take inspiration for biological systems in the design of electronic ones. In SABRE (self-healing cellular architectures for biologically inspired highly reliable electronic systems), we have designed a bio-inspired fault-tolerant hierarchical architecture for this purpose. As in biology, the foundation for the whole system is cellular in nature, with each cell able to detect faults in its operation and trigger intra-cellular or extra-cellular repair as required. At the next level in the hierarchy, arrays of cells are configured and controlled as function units in a transport triggered architecture (TTA), which is able to perform partial-dynamic reconfiguration to rectify problems that cannot be solved at the cellular level. Each TTA is, in turn, part of a larger multi-processor system which employs coarser grain reconfiguration to tolerate faults that cause a processor to fail. In this paper, we describe the details of operation of each layer of the SABRE hierarchy, and how these layers interact to provide a high systemic level of fault tolerance.

  16. Development and validation of electronic surveillance tool for acute kidney injury: A retrospective analysis.

    PubMed

    Ahmed, Adil; Vairavan, Srinivasan; Akhoundi, Abbasali; Wilson, Gregory; Chiofolo, Caitlyn; Chbat, Nicolas; Cartin-Ceba, Rodrigo; Li, Guangxi; Kashani, Kianoush

    2015-10-01

    Timely detection of acute kidney injury (AKI) facilitates prevention of its progress and potentially therapeutic interventions. The study objective is to develop and validate an electronic surveillance tool (AKI sniffer) to detect AKI in 2 independent retrospective cohorts of intensive care unit (ICU) patients. The primary aim is to compare the sensitivity, specificity, and positive and negative predictive values of AKI sniffer performance against a reference standard. This study is conducted in the ICUs of a tertiary care center. The derivation cohort study subjects were Olmsted County, MN, residents admitted to all Mayo Clinic ICUs from July 1, 2010, through December 31, 2010, and the validation cohort study subjects were all patients admitted to a Mayo Clinic, Rochester, campus medical/surgical ICU on January 12, 2010, through March 23, 2010. All included records were reviewed by 2 independent investigators who adjudicated AKI using the Acute Kidney Injury Network criteria; disagreements were resolved by a third reviewer. This constituted the reference standard. An electronic algorithm was developed; its precision and reliability were assessed in comparison with the reference standard in 2 separate cohorts, derivation and validation. Of 1466 screened patients, a total of 944 patients were included in the study: 482 for derivation and 462 for validation. Compared with the reference standard in the validation cohort, the sensitivity and specificity of the AKI sniffer were 88% and 96%, respectively. The Cohen κ (95% confidence interval) agreement between the electronic and the reference standard was 0.84 (0.78-0.89) and 0.85 (0.80-0.90) in the derivation and validation cohorts. Acute kidney injury can reliably and accurately be detected electronically in ICU patients. The presented method is applicable for both clinical (decision support) and research (enrollment for clinical trials) settings. Prospective validation is required. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Microstructural Study of Micron-Sized Craters Simulating Stardust Impacts in Aluminum 1100 Targets

    NASA Technical Reports Server (NTRS)

    Leroux, Hugues; Borg, Janet; Troadec, David; Djouadi, Zahia; Horz, Friedrich

    2006-01-01

    Various microscopic techniques were used to characterize experimental micro- craters in aluminium foils to prepare for the comprehensive analysis of the cometary and interstellar particle impacts in aluminium foils to be returned by the Stardust mission. First, SEM (Scanning Electron Microscopy) and EDS (Energy Dispersive X-ray Spectroscopy) were used to study the morphology of the impact craters and the bulk composition of the residues left by soda-lime glass impactors. A more detailed structural and compositional study of impactor remnants was then performed using TEM (Transmission Electron Microscopy), EDS, and electron diffraction methods. The TEM samples were prepared by Focused Ion Beam (FIB) methods. This technique proved to be especially valuable in studying impact crater residues and impact crater morphology. Finally, we also showed that InfraRed microscopy (IR) can be a quick and reliable tool for such investigations. The combination of all of these tools enables a complete microscopic characterization of the craters.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klem, Michael

    The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory seeks to achieve thermonuclear ignition through inertial confinement fusion. The accurate assessment of the performance of each implosion experiment is a crucial step. Here we report on work to derive a reliable electron temperature for the cryogenic deuteriumtritium implosions completed on the NIF using the xray signal from the Ross filter diagnostic. These Xrays are dominated by bremsstrahlung emission. By fitting the xray signal measured through each of the individual Ross filters, the source bremsstrahlung spectrum can be inferred, and an electron temperature of the implosion hot spot inferred.more » Currently, each filter is weighted equally in this analysis. We present work quantifying the errors with such a technique and the results from investigating the contribution of each filter to the overall accuracy of the temperature inference. Using this research, we also compare the inferred electron temperature against other measured implosion quantities to develop a more complete understanding of the hotspot physics.« less

  19. Advance Care Planning Documentation in Electronic Health Records: Current Challenges and Recommendations for Change.

    PubMed

    Lamas, Daniela; Panariello, Natalie; Henrich, Natalie; Hammes, Bernard; Hanson, Laura C; Meier, Diane E; Guinn, Nancy; Corrigan, Janet; Hubber, Sean; Luetke-Stahlman, Hannah; Block, Susan

    2018-04-01

    To develop a set of clinically relevant recommendations to improve the state of advance care planning (ACP) documentation in the electronic health record (EHR). Advance care planning (ACP) is a key process that supports goal-concordant care. For preferences to be honored, clinicians must be able to reliably record, find, and use ACP documentation. However, there are no standards to guide ACP documentation in the electronic health record (EHR). We interviewed 21 key informants to understand the strengths and weaknesses of EHR documentation systems for ACP and identify best practices. We analyzed these interviews using a qualitative content analysis approach and subsequently developed a preliminary set of recommendations. These recommendations were vetted and refined in a second round of input from a national panel of content experts. Informants identified six themes regarding current inadequacies in documentation and accessibility of ACP information and opportunities for improvement. We offer a set of concise, clinically relevant recommendations, informed by expert opinion, to improve the state of ACP documentation in the EHR.

  20. B-52 stability augmentation system reliability

    NASA Technical Reports Server (NTRS)

    Bowling, T. C.; Key, L. W.

    1976-01-01

    The B-52 SAS (Stability Augmentation System) was developed and retrofitted to nearly 300 aircraft. It actively controls B-52 structural bending, provides improved yaw and pitch damping through sensors and electronic control channels, and puts complete reliance on hydraulic control power for rudder and elevators. The system has experienced over 300,000 flight hours and has exhibited service reliability comparable to the results of the reliability test program. Development experience points out numerous lessons with potential application in the mechanization and development of advanced technology control systems of high reliability.

  1. Electronic Quality of Life Assessment Using Computer-Adaptive Testing

    PubMed Central

    2016-01-01

    Background Quality of life (QoL) questionnaires are desirable for clinical practice but can be time-consuming to administer and interpret, making their widespread adoption difficult. Objective Our aim was to assess the performance of the World Health Organization Quality of Life (WHOQOL)-100 questionnaire as four item banks to facilitate adaptive testing using simulated computer adaptive tests (CATs) for physical, psychological, social, and environmental QoL. Methods We used data from the UK WHOQOL-100 questionnaire (N=320) to calibrate item banks using item response theory, which included psychometric assessments of differential item functioning, local dependency, unidimensionality, and reliability. We simulated CATs to assess the number of items administered before prespecified levels of reliability was met. Results The item banks (40 items) all displayed good model fit (P>.01) and were unidimensional (fewer than 5% of t tests significant), reliable (Person Separation Index>.70), and free from differential item functioning (no significant analysis of variance interaction) or local dependency (residual correlations < +.20). When matched for reliability, the item banks were between 45% and 75% shorter than paper-based WHOQOL measures. Across the four domains, a high standard of reliability (alpha>.90) could be gained with a median of 9 items. Conclusions Using CAT, simulated assessments were as reliable as paper-based forms of the WHOQOL with a fraction of the number of items. These properties suggest that these item banks are suitable for computerized adaptive assessment. These item banks have the potential for international development using existing alternative language versions of the WHOQOL items. PMID:27694100

  2. Reliability and Validity of the Sensory Component of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI): A Systematic Review.

    PubMed

    Hales, M; Biros, E; Reznik, J E

    2015-01-01

    Since 1982, the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) has been used to classify sensation of spinal cord injury (SCI) through pinprick and light touch scores. The absence of proprioception, pain, and temperature within this scale creates questions about its validity and accuracy. To assess whether the sensory component of the ISNCSCI represents a reliable and valid measure of classification of SCI. A systematic review of studies examining the reliability and validity of the sensory component of the ISNCSCI published between 1982 and February 2013 was conducted. The electronic databases MEDLINE via Ovid, CINAHL, PEDro, and Scopus were searched for relevant articles. A secondary search of reference lists was also completed. Chosen articles were assessed according to the Oxford Centre for Evidence-Based Medicine hierarchy of evidence and critically appraised using the McMasters Critical Review Form. A statistical analysis was conducted to investigate the variability of the results given by reliability studies. Twelve studies were identified: 9 reviewed reliability and 3 reviewed validity. All studies demonstrated low levels of evidence and moderate critical appraisal scores. The majority of the articles (~67%; 6/9) assessing the reliability suggested that training was positively associated with better posttest results. The results of the 3 studies that assessed the validity of the ISNCSCI scale were confounding. Due to the low to moderate quality of the current literature, the sensory component of the ISNCSCI requires further revision and investigation if it is to be a useful tool in clinical trials.

  3. Reliability and Validity of the Sensory Component of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI): A Systematic Review

    PubMed Central

    Hales, M.; Biros, E.

    2015-01-01

    Background: Since 1982, the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) has been used to classify sensation of spinal cord injury (SCI) through pinprick and light touch scores. The absence of proprioception, pain, and temperature within this scale creates questions about its validity and accuracy. Objectives: To assess whether the sensory component of the ISNCSCI represents a reliable and valid measure of classification of SCI. Methods: A systematic review of studies examining the reliability and validity of the sensory component of the ISNCSCI published between 1982 and February 2013 was conducted. The electronic databases MEDLINE via Ovid, CINAHL, PEDro, and Scopus were searched for relevant articles. A secondary search of reference lists was also completed. Chosen articles were assessed according to the Oxford Centre for Evidence-Based Medicine hierarchy of evidence and critically appraised using the McMasters Critical Review Form. A statistical analysis was conducted to investigate the variability of the results given by reliability studies. Results: Twelve studies were identified: 9 reviewed reliability and 3 reviewed validity. All studies demonstrated low levels of evidence and moderate critical appraisal scores. The majority of the articles (~67%; 6/9) assessing the reliability suggested that training was positively associated with better posttest results. The results of the 3 studies that assessed the validity of the ISNCSCI scale were confounding. Conclusions: Due to the low to moderate quality of the current literature, the sensory component of the ISNCSCI requires further revision and investigation if it is to be a useful tool in clinical trials. PMID:26363591

  4. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 1: HARP introduction and user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.

  5. Development of Long-Pulse Heating and Current Drive Actuators and Operational Techniques Compatible with a High-Z Divertor and First Wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Guiding

    Accurate measurement of the edge electron density profile is essential to optimizing antenna coupling and assessment of impurity contamination in studying long-pulse plasma heating and current drive in fusion devices. Measurement of the edge density profile has been demonstrated on the US fusion devices such as C-Mod, DIII-D, and TFTR amongst many devices, and has been used for RF loading and impurity modeling calculations for many years. University of Science and Technology of China (USTC) has recently installed a density profile reflectometer system on the EAST fusion device at the Institute of Plasma Physics, Chinese Academy of Sciences in Chinamore » based on the University of California Los Angeles (UCLA)-designed reflectometer system on the DIII-D fusion device at General Atomics Company in San Diego, California. UCLA has been working with USTC to optimize the existing microwave antenna, waveguide system, microwave electronics, and data analysis to produce reliable edge density profiles. During the past budget year, progress has been made in all three major areas: effort to achieve reliable system operations under various EAST operational conditions, effort to optimize system performance, and effort to provide quality density profiles into EAST’s database routinely.« less

  6. The assessment of exploitation process of power for access control system

    NASA Astrophysics Data System (ADS)

    Wiśnios, Michał; Paś, Jacek

    2017-10-01

    The safety of public utility facilities is a function not only of effectiveness of the electronic safety systems, used for protection of property and persons, but it also depends on the proper functioning of their power supply systems. The authors of the research paper analysed the power supply systems, which are used in buildings for the access control system that is integrated with the closed-circuit TV. The Access Control System is a set of electronic, electromechanical and electrical devices and the computer software controlling the operation of the above-mentioned elements, which is aimed at identification of people, vehicles allowed to cross the boundary of the reserved area, to prevent from crossing the reserved area and to generate the alarm signal informing about the attempt of crossing by an unauthorised entity. The industrial electricity with appropriate technical parameters is a basis of proper functioning of safety systems. Only the electricity supply to the systems is not equivalent to the operation continuity provision. In practice, redundant power supply systems are used. In the carried out reliability analysis of the power supply system, various power circuits of the system were taken into account. The reliability and operation requirements for this type of system were also included.

  7. Field emission electron source

    DOEpatents

    Zettl, Alexander Karlwalter; Cohen, Marvin Lou

    2000-01-01

    A novel field emitter material, field emission electron source, and commercially feasible fabrication method is described. The inventive field emission electron source produces reliable electron currents of up to 400 mA/cm.sup.2 at 200 volts. The emitter is robust and the current it produces is not sensitive to variability of vacuum or the distance between the emitter tip and the cathode. The novel emitter has a sharp turn-on near 100 volts.

  8. Ion plated electronic tube device

    DOEpatents

    Meek, T.T.

    1983-10-18

    An electronic tube and associated circuitry which is produced by ion plating techniques. The process is carried out in an automated process whereby both active and passive devices are produced at very low cost. The circuitry is extremely reliable and is capable of functioning in both high radiation and high temperature environments. The size of the electronic tubes produced are more than an order of magnitude smaller than conventional electronic tubes.

  9. An Analytical Methodology for Predicting Repair Time Distributions of Advanced Technology Aircraft.

    DTIC Science & Technology

    1985-12-01

    1984. 3. Barlow, Richard E. "Mathematical Theory of Reliabilitys A Historical Perspective." ZEEE Transactions on Reliability, 33. 16-19 (April 1984...Technology (AU), Wright-Patterson AFB OH, March 1971. 11. Coppola, Anthony. "Reliability Engineering of J- , Electronic Equipment," ZEEE Transactions on...1982. 64. Woodruff, Brian W. at al. "Modified Goodness-o-Fit Tests for Gamma Distributions with Unknown Location and Scale Parameters," ZEEE

  10. Toward reliable and repeatable automated STEM-EDS metrology with high throughput

    NASA Astrophysics Data System (ADS)

    Zhong, Zhenxin; Donald, Jason; Dutrow, Gavin; Roller, Justin; Ugurlu, Ozan; Verheijen, Martin; Bidiuk, Oleksii

    2018-03-01

    New materials and designs in complex 3D architectures in logic and memory devices have raised complexity in S/TEM metrology. In this paper, we report about a newly developed, automated, scanning transmission electron microscopy (STEM) based, energy dispersive X-ray spectroscopy (STEM-EDS) metrology method that addresses these challenges. Different methodologies toward repeatable and efficient, automated STEM-EDS metrology with high throughput are presented: we introduce the best known auto-EDS acquisition and quantification methods for robust and reliable metrology and present how electron exposure dose impacts the EDS metrology reproducibility, either due to poor signalto-noise ratio (SNR) at low dose or due to sample modifications at high dose conditions. Finally, we discuss the limitations of the STEM-EDS metrology technique and propose strategies to optimize the process both in terms of throughput and metrology reliability.

  11. 76 FR 60820 - North American Electric Reliability Corporation; Notice of Technical Conference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RD10-8-000] North American Electric Reliability Corporation; Notice of Technical Conference Take notice that the Federal Energy... Conference will explore the risks of leaving dial-up intelligent electronic devices that are part of the Bulk...

  12. Requirements for conformal coating and staking of printed wiring boards and electronic assemblies

    NASA Technical Reports Server (NTRS)

    1985-01-01

    In order to maintain the high standards of the NASA conformal coating and staking program, this publication: prescribes NASA's requirements for assuring reliable conformal coating and staking for printed wiring boards and electronic assemblies; describes and incorporates basic considerations necessary to assure reliable conformal coating and staking; establishes the supplier's responsibility to train and certify personnel; provides for supplier documentation of the fabrication and inspection procedures to be used for NASA work, including supplier innovations and changes in technology; and provides visual workmanship standards to aid those responsible for determining quality conformance to the established requirements.

  13. Numerical simulation of electron scattering by nanotube junctions

    NASA Astrophysics Data System (ADS)

    Brüning, J.; Grikurov, V. E.

    2008-03-01

    We demonstrate the possibility of computing the intensity of electronic transport through various junctions of three-dimensional metallic nanotubes. In particular, we observe that the magnetic field can be used to control the switch of electron in Y-type junctions. Keeping in mind the asymptotic modeling of reliable nanostructures by quantum graphs, we conjecture that the scattering matrix of the graph should be the same as the scattering matrix of its nanosize-prototype. The numerical computation of the latter gives a method for determining the "gluing" conditions at a graph. Exploring this conjecture, we show that the Kirchhoff conditions (which are commonly used on graphs) cannot be applied to model reliable junctions. This work is a natural extension of the paper [1], but it is written in a self-consistent manner.

  14. Refrigerant leak detector

    NASA Technical Reports Server (NTRS)

    Byrne, E. J.

    1979-01-01

    Quantitative leak detector visually demonstrates refrigerant loss from precision volume of large refrigeration system over established period of time from single test point. Mechanical unit is less costly than electronic "sniffers" and is more reliable due to absence of electronic circuits that are susceptible to drift.

  15. Abutment design for implant-supported indirect composite molar crowns: reliability and fractography.

    PubMed

    Bonfante, Estevam Augusto; Suzuki, Marcelo; Lubelski, William; Thompson, Van P; de Carvalho, Ricardo Marins; Witek, Lukasz; Coelho, Paulo G

    2012-12-01

    To investigate the reliability of titanium abutments veneered with indirect composites for implant-supported crowns and the possibility to trace back the fracture origin by qualitative fractographic analysis. Large base (LB) (6.4-mm diameter base, with a 4-mm high cone in the center for composite retention), small base (SB-4) (5.2-mm base, 4-mm high cone), and small base with cone shortened to 2 mm (SB-2) Ti abutments were used. Each abutment received incremental layers of indirect resin composite until completing the anatomy of a maxillary molar crown. Step-stress accelerated-life fatigue testing (n = 18 each) was performed in water. Weibull curves with use stress of 200 N for 50,000 and 100,000 cycles were calculated. Probability Weibull plots examined the differences between groups. Specimens were inspected in light-polarized and scanning electron microscopes for fractographic analysis. Use level probability Weibull plots showed Beta values of 0.27 for LB, 0.32 for SB-4, and 0.26 for SB-2, indicating that failures were not influenced by fatigue and damage accumulation. The data replotted as Weibull distribution showed no significant difference in the characteristic strengths between LB (794 N) and SB-4 abutments (836 N), which were both significantly higher than SB-2 (601 N). Failure mode was cohesive within the composite for all groups. Fractographic markings showed that failures initiated at the indentation area and propagated toward the margins of cohesively failed composite. Reliability was not influenced by abutment design. Qualitative fractographic analysis of the failed indirect composite was feasible. © 2012 by the American College of Prosthodontists.

  16. [Comparison of new portable home electronic uroflowmeter with Laborie uroflowmeter].

    PubMed

    Guan, Zhi-chen; Deng, Xiao-lin; Zhang, Qian

    2011-08-18

    To design a new portable home electronic uroflowmeter and compare it with traditional methods. The system consists of collectors, urine conducting apparatus, intelligent cell phone, wireless network communication technology, computer analysis and drawing, and data storage technology, etc., and can automatically collect voiding information from patients with lower urinary tract symptoms(LUTS) Through Bluetooth, the voiding information was sent to the patient's intelligent cell phone from the collector, then stored directly by intelligent cell phone and wirelessly transmitted to the workstation in hospital. The system was primarily tested with regard to accuracy of measurement of the voided volume. Multiple doses with known volume were introduced in the system and Laborie uroflowmeter. Furthermore, 38 outpatients who had LUTS were tested simultaneously with the system and Laborie uroflowmeter. The statistical method for assessing agreement between the two methods of clinical measurement was Bland-Altman analysis. Among the subjects, there were 22 male patients and 16 female patients, ranging from 21 to 37 years old, with an average age of 25.5 years, of whom, 19 were tested once and 19 patients twice, equaling to 57 tests. The system could accurately collect and analyze voiding time, uroflowmetry, voided volume, and automatically provide uroflowmetry parameters. The measurement error of 100, 200, 300, 500 and 800 mL is less than 5%. 12.28%, 5.26% and 3.51% of the Qmax, Qave and voided volume points were beyond the 95% limits of agreement. The maximum absolute values of the Qmax, Qave and voided volume difference were 0.38 mL/s, 0.70 mL/s and 2.90 mL, respectively.They agreed with the recommendation of Standardization International Continence Society. The new portable home electronic uroflowmeter has good agreement with Laborie uroflowmeter,and is a new LUTS monitoring system integrated with correct, reliable, real-time, convenient and easy-managing advantages. It is as noninvasive and reliable as traditional methods, and its portable feature facilitates application out of hospitals. It can also record voiding diaries.

  17. Research on c-HfO2 (0 0 1)/α -Al2O3 (1 -1 0 2) interface in CTM devices based on first principle theory

    NASA Astrophysics Data System (ADS)

    Lu, Wenjuan; Dai, Yuehua; Wang, Feifei; Yang, Fei; Ma, Chengzhi; Zhang, Xu; Jiang, Xianwei

    2017-12-01

    With the growing application of high-k dielectrics, the interface between HfO2 and Al2O3 play a crucial role in CTM devices. To clearly understand the interaction of the HfO-AlO interface at the atomic and electronic scale, the bonding feature, electronic properties and charge localized character of c- HfO2 (0 0 1)/α-Al2O3 (1 -1 0 2) interface has been investigated by first principle calculations. The c- HfO2 (0 0 1)/α-Al2O3 (1 -1 0 2) interface has adhesive energy about -1.754 J/m2, suggesting that this interface can exist stably. Through analysis of Bader charge and charge density difference, the intrinsic interfacial gap states are mainly originated from the OII and OIII types oxygen atoms at the interface, and only OIII type oxygen atoms can localized electrons effectively and are provided with good reliability during P/E cycles, which theoretically validate the experimental results that HfO2/Al2O3 multi-layered charge trapping layer can generate more effective traps in memory device. Furthermore, the influence of interfacial gap states during P/E cycles in the defective interface system have also been studied, and the results imply that defective system displays the degradation on the reliability during P/E cycles, while, the charge localized ability of interfacial states is stronger than intrinsic oxygen vacancy in the trapping layer. Besides, these charge localized characters are further explained by the analysis of the density of states correspondingly. In sum, our results compare well with similar experimental observations in other literatures, and the study of the interfacial gap states in this work would facilitate further development of interface passivation.

  18. Writing and reading in the electronic health record: an entirely new world.

    PubMed

    Han, Heeyoung; Lopp, Lauri

    2013-02-05

    Electronic health records (EHRs) are structured, distributed documentation systems that differ from paper charts. These systems require skills not traditionally used to navigate a paper chart and to produce a written clinic note. Despite these differences, little attention has been given to physicians' electronic health record (EHR)-writing and -reading competence. This study aims to investigate physicians' self-assessed competence to document and to read EHR notes; writing and reading preferences in an EHR; and demographic characteristics associated with their perceived EHR ability and preference. Fourteen 5-point Likert scale items, based on EHR system characteristics and a literature review, were developed to measure EHR-writing and -reading competence and preference. Physicians in the midwest region of the United States were invited via e-mail to complete the survey online from February to April 2011. Factor analysis and reliability testing were conducted to provide validity and reliability of the instrument. Correlation and regression analysis were conducted to pursue answers to the research questions. Ninety-one physicians (12.5%), from general and specialty fields, working in inpatient and outpatient settings, participated in the survey. Despite over 3 years of EHR experience, respondents perceived themselves to be incompetent in EHR writing and reading (Mean = 2.74, SD = 0.76). They preferred to read succinct, narrative notes in EHR systems. However, physicians with higher perceived EHR-writing and -reading competence had less preference toward reading succinct (r= - 0.33, p<0.001) and narrative (r= - 0.36, p<0.001) EHR notes than physicians with lower perceived EHR competence. Physicians' perceived EHR-writing and -reading competence was strongly related to their EHR navigation skills (r=0.55, p<0.0001). Writing and reading EHR documentation is different for physicians. Maximizing navigation skills can optimize non-linear EHR writing and reading. Pedagogical questions remain related to how physicians and medical students are able to retrieve correct information effectively and to understand thought patterns in collectively lengthier and sometimes fragmented EHR chart notes.

  19. Being an Informed Consumer of Health Information and Assessment of Electronic Health Literacy in a National Sample of Internet Users: Validity and Reliability of the e-HLS Instrument.

    PubMed

    Seçkin, Gül; Yeatts, Dale; Hughes, Susan; Hudson, Cassie; Bell, Valarie

    2016-07-11

    The Internet, with its capacity to provide information that transcends time and space barriers, continues to transform how people find and apply information to their own lives. With the current explosion in electronic sources of health information, including thousands of websites and hundreds of mobile phone health apps, electronic health literacy is gaining an increasing prominence in health and medical research. An important dimension of electronic health literacy is the ability to appraise the quality of information that will facilitate everyday health care decisions. Health information seekers explore their care options by gathering information from health websites, blogs, Web-based forums, social networking websites, and advertisements, despite the fact that information quality on the Internet varies greatly. Nonetheless, research has lagged behind in establishing multidimensional instruments, in part due to the evolving construct of health literacy itself. The purpose of this study was to examine psychometric properties of a new electronic health literacy (ehealth literacy) measure in a national sample of Internet users with specific attention to older users. Our paper is motivated by the fact that ehealth literacy is an underinvestigated area of inquiry. Our sample was drawn from a panel of more than 55,000 participants maintained by Knowledge Networks, the largest national probability-based research panel for Web-based surveys. We examined the factor structure of a 19-item electronic Health Literacy Scale (e-HLS) through exploratory factor analysis (EFA) and confirmatory factor analysis, internal consistency reliability, and construct validity on sample of adults (n=710) and a subsample of older adults (n=194). The AMOS graphics program 21.0 was used to construct a measurement model, linking latent factors obtained from EFA with 19 indicators to determine whether this factor structure achieved a good fit with our entire sample and the subsample (age ≥ 60 years). Linear regression analyses were performed in separate models to examine: (1) the construct validity of the e-HLS and (2) its association with respondents' demographic characteristics and health variables. The EFA produced a 3-factor solution: communication (2 items), trust (4 items), and action (13 items). The 3-factor structure of the e-HLS was found to be invariant for the subsample. Fit indices obtained were as follows: full sample: χ(2) (710)=698.547, df=131, P<.001, comparative fit index (CFI)=0.94, normed fit index (NFI)=0.92, root mean squared error of approximation (RMSEA)=0.08; and for the older subsample (age ≥ 60 years): χ(2) (194)=275.744, df=131, P<.001, CFI=0.95, NFI=0.90, RMSEA=0.08. The analyses supported the e-HLS validity and internal reliability for the full sample and subsample. The overwhelming majority of our respondents reported a great deal of confidence in their ability to appraise the quality of information obtained from the Internet, yet less than half reported performing quality checks contained on the e-HLS.

  20. Being an Informed Consumer of Health Information and Assessment of Electronic Health Literacy in a National Sample of Internet Users: Validity and Reliability of the e-HLS Instrument

    PubMed Central

    Yeatts, Dale; Hughes, Susan; Hudson, Cassie; Bell, Valarie

    2016-01-01

    Background The Internet, with its capacity to provide information that transcends time and space barriers, continues to transform how people find and apply information to their own lives. With the current explosion in electronic sources of health information, including thousands of websites and hundreds of mobile phone health apps, electronic health literacy is gaining an increasing prominence in health and medical research. An important dimension of electronic health literacy is the ability to appraise the quality of information that will facilitate everyday health care decisions. Health information seekers explore their care options by gathering information from health websites, blogs, Web-based forums, social networking websites, and advertisements, despite the fact that information quality on the Internet varies greatly. Nonetheless, research has lagged behind in establishing multidimensional instruments, in part due to the evolving construct of health literacy itself. Objective The purpose of this study was to examine psychometric properties of a new electronic health literacy (ehealth literacy) measure in a national sample of Internet users with specific attention to older users. Our paper is motivated by the fact that ehealth literacy is an underinvestigated area of inquiry. Methods Our sample was drawn from a panel of more than 55,000 participants maintained by Knowledge Networks, the largest national probability-based research panel for Web-based surveys. We examined the factor structure of a 19-item electronic Health Literacy Scale (e-HLS) through exploratory factor analysis (EFA) and confirmatory factor analysis, internal consistency reliability, and construct validity on sample of adults (n=710) and a subsample of older adults (n=194). The AMOS graphics program 21.0 was used to construct a measurement model, linking latent factors obtained from EFA with 19 indicators to determine whether this factor structure achieved a good fit with our entire sample and the subsample (age ≥ 60 years). Linear regression analyses were performed in separate models to examine: (1) the construct validity of the e-HLS and (2) its association with respondents’ demographic characteristics and health variables. Results The EFA produced a 3-factor solution: communication (2 items), trust (4 items), and action (13 items). The 3-factor structure of the e-HLS was found to be invariant for the subsample. Fit indices obtained were as follows: full sample: χ2 (710)=698.547, df=131, P<.001, comparative fit index (CFI)=0.94, normed fit index (NFI)=0.92, root mean squared error of approximation (RMSEA)=0.08; and for the older subsample (age ≥ 60 years): χ2 (194)=275.744, df=131, P<.001, CFI=0.95, NFI=0.90, RMSEA=0.08. Conclusions The analyses supported the e-HLS validity and internal reliability for the full sample and subsample. The overwhelming majority of our respondents reported a great deal of confidence in their ability to appraise the quality of information obtained from the Internet, yet less than half reported performing quality checks contained on the e-HLS. PMID:27400726

  1. Reliability Practice at NASA Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Pruessner, Paula S.; Li, Ming

    2008-01-01

    This paper describes in brief the Reliability and Maintainability (R&M) Programs performed directly by the reliability branch at Goddard Space Flight Center (GSFC). The mission assurance requirements flow down is explained. GSFC practices for PRA, reliability prediction/fault tree analysis/reliability block diagram, FMEA, part stress and derating analysis, worst case analysis, trend analysis, limit life items are presented. Lessons learned are summarized and recommendations on improvement are identified.

  2. Bright-field electron tomography of individual inorganic fullerene-like structures

    NASA Astrophysics Data System (ADS)

    Bar Sadan, Maya; Wolf, Sharon G.; Houben, Lothar

    2010-03-01

    Nanotubes and fullerene-like nanoparticles of various inorganic layered compounds have been studied extensively in recent years. Their characterisation on the atomic scale has proven essential for progress in synthesis as well as for the theoretical modelling of their physical properties. We show that with electron tomography it is possible to achieve a reliable reconstruction of the 3D structure of nested WS2 or MoS2 fullerene-like and nanotube structures with sub-nanometre resolution using electron microscopes that are not aberration-corrected. Model-based simulations were used to identify imaging parameters, under which structural features such as the shell structure can be retained in the tomogram reconstructed from bright-field micrographs. The isolation of a particle out of an agglomerate for the analysis of a single structure and its interconnection with other particles is facilitated through the tomograms. The internal structure of the layers within the particle alongside the shape and content of its internal void are reconstructed. The tomographic reconstruction yields insights regarding the growth process as well as structural defects, such as non-continuous layers, which relate to the lubrication properties.Nanotubes and fullerene-like nanoparticles of various inorganic layered compounds have been studied extensively in recent years. Their characterisation on the atomic scale has proven essential for progress in synthesis as well as for the theoretical modelling of their physical properties. We show that with electron tomography it is possible to achieve a reliable reconstruction of the 3D structure of nested WS2 or MoS2 fullerene-like and nanotube structures with sub-nanometre resolution using electron microscopes that are not aberration-corrected. Model-based simulations were used to identify imaging parameters, under which structural features such as the shell structure can be retained in the tomogram reconstructed from bright-field micrographs. The isolation of a particle out of an agglomerate for the analysis of a single structure and its interconnection with other particles is facilitated through the tomograms. The internal structure of the layers within the particle alongside the shape and content of its internal void are reconstructed. The tomographic reconstruction yields insights regarding the growth process as well as structural defects, such as non-continuous layers, which relate to the lubrication properties. Electronic supplementary information (ESI) available: Figs. S1 and S2 and movies S1-S6. See DOI: 10.1039/b9nr00251k

  3. Development and preliminary evidence for the validity of an instrument assessing implementation of human-factors principles in medication-related decision-support systems—I-MeDeSA

    PubMed Central

    Zachariah, Marianne; Seidling, Hanna M; Neri, Pamela M; Cresswell, Kathrin M; Duke, Jon; Bloomrosen, Meryl; Volk, Lynn A; Bates, David W

    2011-01-01

    Background Medication-related decision support can reduce the frequency of preventable adverse drug events. However, the design of current medication alerts often results in alert fatigue and high over-ride rates, thus reducing any potential benefits. Methods The authors previously reviewed human-factors principles for relevance to medication-related decision support alerts. In this study, instrument items were developed for assessing the appropriate implementation of these human-factors principles in drug–drug interaction (DDI) alerts. User feedback regarding nine electronic medical records was considered during the development process. Content validity, construct validity through correlation analysis, and inter-rater reliability were assessed. Results The final version of the instrument included 26 items associated with nine human-factors principles. Content validation on three systems resulted in the addition of one principle (Corrective Actions) to the instrument and the elimination of eight items. Additionally, the wording of eight items was altered. Correlation analysis suggests a direct relationship between system age and performance of DDI alerts (p=0.0016). Inter-rater reliability indicated substantial agreement between raters (κ=0.764). Conclusion The authors developed and gathered preliminary evidence for the validity of an instrument that measures the appropriate use of human-factors principles in the design and display of DDI alerts. Designers of DDI alerts may use the instrument to improve usability and increase user acceptance of medication alerts, and organizations selecting an electronic medical record may find the instrument helpful in meeting their clinicians' usability needs. PMID:21946241

  4. New pediatric vision screener, part II: electronics, software, signal processing and validation.

    PubMed

    Gramatikov, Boris I; Irsch, Kristina; Wu, Yi-Kai; Guyton, David L

    2016-02-04

    We have developed an improved pediatric vision screener (PVS) that can reliably detect central fixation, eye alignment and focus. The instrument identifies risk factors for amblyopia, namely eye misalignment and defocus. The device uses the birefringence of the human fovea (the most sensitive part of the retina). The optics have been reported in more detail previously. The present article focuses on the electronics and the analysis algorithms used. The objective of this study was to optimize the analog design, data acquisition, noise suppression techniques, the classification algorithms and the decision making thresholds, as well as to validate the performance of the research instrument on an initial group of young test subjects-18 patients with known vision abnormalities (eight male and 10 female), ages 4-25 (only one above 18) and 19 controls with proven lack of vision issues. Four statistical methods were used to derive decision making thresholds that would best separate patients with abnormalities from controls. Sensitivity and specificity were calculated for each method, and the most suitable one was selected. Both the central fixation and the focus detection criteria worked robustly and allowed reliable separation between normal test subjects and symptomatic subjects. The sensitivity of the instrument was 100 % for both central fixation and focus detection. The specificity was 100 % for central fixation and 89.5 % for focus detection. The overall sensitivity was 100 % and the overall specificity was 94.7 %. Despite the relatively small initial sample size, we believe that the PVS instrument design, the analysis methods employed, and the device as a whole, will prove valuable for mass screening of children.

  5. Fracture Behaviors of Sn-Cu Intermetallic Compound Layer in Ball Grid Array Induced by Thermal Shock

    NASA Astrophysics Data System (ADS)

    Shen, Jun; Zhai, Dajun; Cao, Zhongming; Zhao, Mali; Pu, Yayun

    2014-02-01

    In this work, thermal shock reliability testing and finite-element analysis (FEA) of solder joints between ball grid array components and printed circuit boards with Cu pads were used to investigate the failure mechanism of solder interconnections. The morphologies, composition, and thickness of Sn-Cu intermetallic compounds (IMC) at the interface of Sn-3.0Ag-0.5Cu lead-free solder alloy and Cu substrates were investigated by scanning electron microscopy and transmission electron microscopy. Based on the experimental observations and FEA results, it can be recognized that the origin and propagation of cracks are caused primarily by the difference between the coefficient of thermal expansion of different parts of the packaged products, the growth behaviors and roughness of the IMC layer, and the grain size of the solder balls.

  6. Self-Cleaning Anticondensing Glass via Supersonic Spraying of Silver Nanowires, Silica, and Polystyrene Nanoparticles.

    PubMed

    Lee, Jong-Gun; An, Seongpil; Kim, Tae-Gun; Kim, Min-Woo; Jo, Hong-Seok; Swihart, Mark T; Yarin, Alexander L; Yoon, Sam S

    2017-10-11

    We have sequentially deposited layers of silver nanowires (AgNWs), silicon dioxide (SiO 2 ) nanoparticles, and polystyrene (PS) nanoparticles on uncoated glass by a rapid low-cost supersonic spraying method to create antifrosting, anticondensation, and self-cleaning glass. The conductive silver nanowire network embedded in the coating allows electrical heating of the glass surface. Supersonic spraying is a single-step coating technique that does not require vacuum. The fabricated multifunctional glass was characterized by X-ray diffraction analysis (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), ultraviolet-visible spectroscopy, and transmission electron microscopy (TEM). The thermal insulation and antifrosting performance were demonstrated using infrared thermal imaging. The reliability of the electrical heating function was tested through extensive cycling. This transparent multifunctional coating holds great promise for use in various smart window designs.

  7. Correlative Förster Resonance Electron Transfer-Proximity Ligation Assay (FRET-PLA) Technique for Studying Interactions Involving Membrane Proteins.

    PubMed

    Ivanusic, Daniel; Denner, Joachim; Bannert, Norbert

    2016-08-01

    This unit provides a guide and detailed protocol for studying membrane protein-protein interactions (PPI) using the acceptor-sensitized Förster resonance electron transfer (FRET) method in combination with the proximity ligation assay (PLA). The protocol in this unit is focused on the preparation of FRET-PLA samples and the detection of correlative FRET/PLA signals as well as on the analysis of FRET-PLA data and interpretation of correlative results when using cyan fluorescent protein (CFP) as a FRET donor and yellow fluorescent protein (YFP) as a FRET acceptor. The correlative application of FRET and PLA combines two powerful tools for monitoring PPI, yielding results that are more reliable than with either technique alone. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.

  8. Research on ionospheric tomography based on variable pixel height

    NASA Astrophysics Data System (ADS)

    Zheng, Dunyong; Li, Peiqing; He, Jie; Hu, Wusheng; Li, Chaokui

    2016-05-01

    A novel ionospheric tomography technique based on variable pixel height was developed for the tomographic reconstruction of the ionospheric electron density distribution. The method considers the height of each pixel as an unknown variable, which is retrieved during the inversion process together with the electron density values. In contrast to conventional computerized ionospheric tomography (CIT), which parameterizes the model with a fixed pixel height, the variable-pixel-height computerized ionospheric tomography (VHCIT) model applies a disturbance to the height of each pixel. In comparison with conventional CIT models, the VHCIT technique achieved superior results in a numerical simulation. A careful validation of the reliability and superiority of VHCIT was performed. According to the results of the statistical analysis of the average root mean square errors, the proposed model offers an improvement by 15% compared with conventional CIT models.

  9. A Year in the Life of the NASA Electronic Parts and Packaging (NEPP) Program

    NASA Technical Reports Server (NTRS)

    Label, Kenneth A.

    2017-01-01

    NEPP Mission Statement: Provide NASAs leadership for developing and maintaining guidance for the screening, qualification, test, and reliable usage of electrical, electronic, and electromechanical (EEE) parts by NASA, in collaboration with other government Agencies and industry.

  10. dc-plasma-sprayed electronic-tube device

    DOEpatents

    Meek, T.T.

    1982-01-29

    An electronic tube and associated circuitry which is produced by dc plasma arc spraying techniques is described. The process is carried out in a single step automated process whereby both active and passive devices are produced at very low cost. The circuitry is extremely reliable and is capable of functioning in both high radiation and high temperature environments. The size of the electronic tubes produced are more than an order of magnitude smaller than conventional electronic tubes.

  11. Lithium Battery Transient Response as a Diagnostic Tool

    NASA Astrophysics Data System (ADS)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  12. Back-bombardment compensation in microwave thermionic electron guns

    NASA Astrophysics Data System (ADS)

    Kowalczyk, Jeremy M. D.; Madey, John M. J.

    2014-12-01

    The development of capable, reliable, and cost-effective compact electron beam sources remains a long-standing objective of the efforts to develop the accelerator systems needed for on-site research and industrial applications ranging from electron beam welding to high performance x-ray and gamma ray light sources for element-resolved microanalysis and national security. The need in these applications for simplicity, reliability, and low cost has emphasized solutions compatible with the use of the long established and commercially available pulsed microwave rf sources and L-, S- or X-band linear accelerators. Thermionic microwave electron guns have proven to be one successful approach to the development of the electron sources for these systems providing high macropulse average current beams with picosecond pulse lengths and good emittance out to macropulse lengths of 4-5 microseconds. But longer macropulse lengths are now needed for use in inverse-Compton x-ray sources and other emerging applications. We describe in this paper our approach to extending the usable macropulse current and pulse length of these guns through the use of thermal diffusion to compensate for the increase in cathode surface temperature due to back-bombardment.

  13. Electronic drive and acquisition system for mass spectrometry

    NASA Technical Reports Server (NTRS)

    Schaefer, Rembrandt Thomas (Inventor); Chutjian, Ara (Inventor); Tran, Tuan (Inventor); Madzunkov, Stojan M. (Inventor); Thomas, John L. (Inventor); Mojarradi, Mohammad (Inventor); MacAskill, John (Inventor); Blaes, Brent R. (Inventor); Darrach, Murray R. (Inventor); Burke, Gary R. (Inventor)

    2010-01-01

    The present invention discloses a mixed signal RF drive electronics board that offers small, low power, reliable, and customizable method for driving and generating mass spectra from a mass spectrometer, and for control of other functions such as electron ionizer, ion focusing, single-ion detection, multi-channel data accumulation and, if desired, front-end interfaces such as pumps, valves, heaters, and columns.

  14. Electronic switches and control circuits: A compilation

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The innovations in this updated series of compilations dealing with electronic technology represents a carefully selected collection of items on electronic switches and control circuits. Most of the items are based on well-known circuit design concepts that have been simplified or refined to meet NASA's demanding requirement for reliability, simplicity, fail-safe characteristics, and the capability of withstanding environmental extremes.

  15. Lead-Free vs Tin-Lead Reliability of Advanced Electronic Assemblies

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2005-01-01

    This presentation will provide the technical background and specific information published in literature related to reliability test, analyses, modeling, and associated issues for lead-free solder package assemblies in comparison to their tin-lead solder alloys. It also presents current understanding of lead-free thermal cycle test performance in support.

  16. Understanding metallic bonding: Structure, process and interaction by Rasch analysis

    NASA Astrophysics Data System (ADS)

    Cheng, Maurice M. W.; Oon, Pey-Tee

    2016-08-01

    This paper reports the results of a survey of 3006 Year 10-12 students on their understandings of metallic bonding. The instrument was developed based on Chi's ontological categories of scientific concepts and students' understanding of metallic bonding as reported in the literature. The instrument has two parts. Part one probed into students' understanding of metallic bonding as (a) a submicro structure of metals, (b) a process in which individual metal atoms lose their outermost shell electrons to form a 'sea of electrons' and octet metal cations or (c) an all-directional electrostatic force between delocalized electrons and metal cations, that is, an interaction. Part two assessed students' explanation of malleability of metals, for example (a) as a submicro structural rearrangement of metal atoms/cations or (b) based on all-directional electrostatic force. The instrument was validated by the Rasch Model. Psychometric assessment showed that the instrument possessed reasonably good properties of measurement. Results revealed that it was reliable and valid for measuring students' understanding of metallic bonding. Analysis revealed that the structure, process and interaction understandings were unidimensional and in an increasing order of difficulty. Implications for the teaching of metallic bonding, particular through the use of diagrams, critiques and model-based learning, are discussed.

  17. Nuclear Tools For Oilfield Logging-While-Drilling Applications

    NASA Astrophysics Data System (ADS)

    Reijonen, Jani

    2011-06-01

    Schlumberger is an international oilfield service company with nearly 80,000 employees of 140 nationalities, operating globally in 80 countries. As a market leader in oilfield services, Schlumberger has developed a suite of technologies to assess the downhole environment, including, among others, electromagnetic, seismic, chemical, and nuclear measurements. In the past 10 years there has been a radical shift in the oilfield service industry from traditional wireline measurements to logging-while-drilling (LWD) analysis. For LWD measurements, the analysis is performed and the instruments are operated while the borehole is being drilled. The high temperature, high shock, and extreme vibration environment of LWD imposes stringent requirements for the devices used in these applications. This has a significant impact on the design of the components and subcomponents of a downhole tool. Another significant change in the past few years for nuclear-based oilwell logging tools is the desire to replace the sealed radioisotope sources with active, electronic ones. These active radiation sources provide great benefits compared to the isotopic sources, ranging from handling and safety to nonproliferation and well contamination issues. The challenge is to develop electronic generators that have a high degree of reliability for the entire lifetime of a downhole tool. LWD tool testing and operations are highlighted with particular emphasis on electronic radiation sources and nuclear detectors for the downhole environment.

  18. The problem of deriving the field-induced thermal emission in Poole-Frenkel theories

    NASA Astrophysics Data System (ADS)

    Ongaro, R.; Pillonnet, A.

    1992-10-01

    A discussion is made of the legitimity of implementing the usual model of field-assisted release of electrons, over the lowered potential barrier of donors. It is stressed that no reliable interpretation can avail for the usual modelling of wells, on which Poole-Frenkel (PF) derivations are established. This is so because there does not seem to exist reliable ways of implanting a Coulomb potential well in the gap of a material. In an attempt to bridge the gap between the classical potential-energy approaches and the total-energy approach of Mahapatra and Roy, a Bohr-type model of wells is proposed. In addition, a brief review of quantum treatments of electronic transport in materials is presented, in order to see if more reliable ways of approaching PF effect can be derived on undisputable bases. Finally, it is concluded that, presently, PF effect can be established safely neither theoretically nor experimentally.

  19. NASA Electronic Parts and Packaging (NEPP) - A NASA Office of Safety and Mission Assurance (OSMA) Program

    NASA Technical Reports Server (NTRS)

    Label, Kenneth A.

    2017-01-01

    NEPP Mission Statement: Provide NASA's leadership for developing and maintaining guidance for the screening, qualification, test, and reliable usage of electrical, electronic, and electromechanical (EEE) parts by NASA, in collaboration with other government Agencies and industry.

  20. E-health strategies to support adherence

    USDA-ARS?s Scientific Manuscript database

    Adherence to healthy behaviors and self-care strategies is a concern among clinicians. E-health applications, such as the internet, personal communication devices, electronic health records and web portals, and electronic games, may be a way to provide health information in a way that is reliable, c...

  1. Conformable wearable systems comprising organic electronics on foil for well being and healthcare (presentation video)

    NASA Astrophysics Data System (ADS)

    de Kok, Margreet M.

    2014-10-01

    Integration of electronics into materials and objects that have not been functionalized with electronics before, open up extensive possibilities to support mankind. By adding intelligence and/or operating power to materials in close skin contact like clothing, furniture or bandages the health of people can be monitored or even improved. Foil based electronics are interesting components to be integrated as they are thin, large area and cost effective available components Our developed technology of printed electronic structures to which components are reliably bonded, fulfills the promise. We have integrated these components into textiles and built wearable encapsulated products with foil based electronics. Foil components with organic and inorganic LEDs are interconnected and laminated onto electronic textiles by using conductive adhesives to bond the contact pads of the component to conductive yarns in the textile. Modelling and reliability testing under dynamic circumstances provided important insights in order to optimise the technology. The design of the interconnection and choice of conductive adhesive / underfill and lamination contributed to the durability of the system. Transition zones from laminated foil to textile are engineered to withstand dynamic use. As an example of a product, we have realized an electronic wristband that is encapsulated in rubber and has a number of sensor functionalities integrated on stretchable electronic circuits based on Cu and Ag. The encapsulation with silicone or polyurethanes was performed such, that charging and sensor/skin contacts are possible while simultaneously protecting the electronics from mechanical and environmental stresses.

  2. Ultracompliant Heterogeneous Copper-Tin Nanowire Arrays Making a Supersolder.

    PubMed

    Gong, Wei; Li, Pengfei; Zhang, Yunheng; Feng, Xuhui; Major, Joshua; DeVoto, Douglas; Paret, Paul; King, Charles; Narumanchi, Sreekant; Shen, Sheng

    2018-06-13

    Due to the substantial increase in power density, thermal interface resistance that can constitute more than 50% of the total thermal resistance has generally become a bottleneck for thermal management in electronics. However, conventional thermal interface materials (TIMs) such as solder, epoxy, gel, and grease cannot fulfill the requirements of electronics for high-power and long-term operation. Here, we demonstrate a high-performance TIM consisting of a heterogeneous copper-tin nanowire array, which we term "supersolder" to emulate the role of conventional solders in bonding various surfaces. The supersolder is ultracompliant with a shear modulus 2-3 orders of magnitude lower than traditional solders and can reduce the thermal resistance by two times as compared with the state-of-the-art TIMs. This supersolder also exhibits excellent long-term reliability with >1200 thermal cycles over a wide temperature range. By resolving this critical thermal bottleneck, the supersolder enables electronic systems, ranging from microelectronics and portable electronics to massive data centers, to operate at lower temperatures with higher power density and reliability.

  3. Lifetime Reliability Prediction of Ceramic Structures Under Transient Thermomechanical Loads

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Jadaan, Osama J.; Gyekenyesi, John P.

    2005-01-01

    An analytical methodology is developed to predict the probability of survival (reliability) of ceramic components subjected to harsh thermomechanical loads that can vary with time (transient reliability analysis). This capability enables more accurate prediction of ceramic component integrity against fracture in situations such as turbine startup and shutdown, operational vibrations, atmospheric reentry, or other rapid heating or cooling situations (thermal shock). The transient reliability analysis methodology developed herein incorporates the following features: fast-fracture transient analysis (reliability analysis without slow crack growth, SCG); transient analysis with SCG (reliability analysis with time-dependent damage due to SCG); a computationally efficient algorithm to compute the reliability for components subjected to repeated transient loading (block loading); cyclic fatigue modeling using a combined SCG and Walker fatigue law; proof testing for transient loads; and Weibull and fatigue parameters that are allowed to vary with temperature or time. Component-to-component variation in strength (stochastic strength response) is accounted for with the Weibull distribution, and either the principle of independent action or the Batdorf theory is used to predict the effect of multiaxial stresses on reliability. The reliability analysis can be performed either as a function of the component surface (for surface-distributed flaws) or component volume (for volume-distributed flaws). The transient reliability analysis capability has been added to the NASA CARES/ Life (Ceramic Analysis and Reliability Evaluation of Structures/Life) code. CARES/Life was also updated to interface with commercially available finite element analysis software, such as ANSYS, when used to model the effects of transient load histories. Examples are provided to demonstrate the features of the methodology as implemented in the CARES/Life program.

  4. Long-life mission reliability for outer planet atmospheric entry probes

    NASA Technical Reports Server (NTRS)

    Mccall, M. T.; Rouch, L.; Maycock, J. N.

    1976-01-01

    The results of a literature analysis on the effects of prolonged exposure to deep space environment on the properties of outer planet atmospheric entry probe components are presented. Materials considered included elastomers and plastics, pyrotechnic devices, thermal control components, metal springs and electronic components. The rates of degradation of each component were determined and extrapolation techniques were used to predict the effects of exposure for up to eight years to deep space. Pyrotechnic devices were aged under accelerated conditions to an equivalent of eight years in space and functionally tested. Results of the literature analysis of the selected components and testing of the devices indicated that no severe degradation should be expected during an eight year space mission.

  5. Thermal Cycling Life Prediction of Sn-3.0Ag-0.5Cu Solder Joint Using Type-I Censored Data

    PubMed Central

    Mi, Jinhua; Yang, Yuan-Jian; Huang, Hong-Zhong

    2014-01-01

    Because solder joint interconnections are the weaknesses of microelectronic packaging, their reliability has great influence on the reliability of the entire packaging structure. Based on an accelerated life test the reliability assessment and life prediction of lead-free solder joints using Weibull distribution are investigated. The type-I interval censored lifetime data were collected from a thermal cycling test, which was implemented on microelectronic packaging with lead-free ball grid array (BGA) and fine-pitch ball grid array (FBGA) interconnection structures. The number of cycles to failure of lead-free solder joints is predicted by using a modified Engelmaier fatigue life model and a type-I censored data processing method. Then, the Pan model is employed to calculate the acceleration factor of this test. A comparison of life predictions between the proposed method and the ones calculated directly by Matlab and Minitab is conducted to demonstrate the practicability and effectiveness of the proposed method. At last, failure analysis and microstructure evolution of lead-free solders are carried out to provide useful guidance for the regular maintenance, replacement of substructure, and subsequent processing of electronic products. PMID:25121138

  6. Dual-angle, self-calibrating Thomson scattering measurements in RFX-MOD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giudicotti, L., E-mail: leonardo.giudicotti@unipd.it; Department of Industrial Engineering, Padova University, Via Gradenigo 6/a, 35131 Padova; Pasqualotto, R.

    2014-11-15

    In the multipoint Thomson scattering (TS) system of the RFX-MOD experiment the signals from a few spatial positions can be observed simultaneously under two different scattering angles. In addition the detection system uses optical multiplexing by signal delays in fiber optic cables of different length so that the two sets of TS signals can be observed by the same polychromator. Owing to the dependence of the TS spectrum on the scattering angle, it was then possible to implement self-calibrating TS measurements in which the electron temperature T{sub e}, the electron density n{sub e} and the relative calibration coefficients of spectralmore » channels sensitivity C{sub i} were simultaneously determined by a suitable analysis of the two sets of TS data collected at the two angles. The analysis has shown that, in spite of the small difference in the spectra obtained at the two angles, reliable values of the relative calibration coefficients can be determined by the analysis of good S/N dual‑angle spectra recorded in a few tens of plasma shots. This analysis suggests that in RFX-MOD the calibration of the entire set of TS polychromators by means of the similar, dual-laser (Nd:YAG/Nd:YLF) TS technique, should be feasible.« less

  7. Power Electronics Thermal Management Research: Annual Progress Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreno, Gilberto

    The objective for this project is to develop thermal management strategies to enable efficient and high-temperature wide-bandgap (WBG)-based power electronic systems (e.g., emerging inverter and DC-DC converter). Reliable WBG devices are capable of operating at elevated temperatures (≥ 175 °Celsius). However, packaging WBG devices within an automotive inverter and operating them at higher junction temperatures will expose other system components (e.g., capacitors and electrical boards) to temperatures that may exceed their safe operating limits. This creates challenges for thermal management and reliability. In this project, system-level thermal analyses are conducted to determine the effect of elevated device temperatures on invertermore » components. Thermal modeling work is then conducted to evaluate various thermal management strategies that will enable the use of highly efficient WBG devices with automotive power electronic systems.« less

  8. Dose limited reliability of quantitative annular dark field scanning transmission electron microscopy for nano-particle atom-counting.

    PubMed

    De Backer, A; Martinez, G T; MacArthur, K E; Jones, L; Béché, A; Nellist, P D; Van Aert, S

    2015-04-01

    Quantitative annular dark field scanning transmission electron microscopy (ADF STEM) has become a powerful technique to characterise nano-particles on an atomic scale. Because of their limited size and beam sensitivity, the atomic structure of such particles may become extremely challenging to determine. Therefore keeping the incoming electron dose to a minimum is important. However, this may reduce the reliability of quantitative ADF STEM which will here be demonstrated for nano-particle atom-counting. Based on experimental ADF STEM images of a real industrial catalyst, we discuss the limits for counting the number of atoms in a projected atomic column with single atom sensitivity. We diagnose these limits by combining a thorough statistical method and detailed image simulations. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Comparative absorption, electroabsorption and electrochemical studies of intervalence electron transfer and electronic coupling in cyanide-bridged bimetallic systems: ancillary ligand effects

    NASA Astrophysics Data System (ADS)

    Vance, Fredrick W.; Slone, Robert V.; Stern, Charlotte L.; Hupp, Joseph T.

    2000-03-01

    Electroabsorption or Stark spectroscopy has been used to evaluate the systems (NC) 5M II-CN-Ru III(NH 3) 51- and (NC) 5M II-CN-Ru III(NH 3) 4py 1-, where M II=Fe II or Ru II. When a pyridine ligand is present in the axial position on the Ru III acceptor, the effective optical electron transfer distance - as measured by the change in dipole moment, |Δ μ| - is increased by more than 35% relative to the ammine substituted counterpart. Comparison of the charge transfer distances to the crystal structure of Na[(CN) 5Fe-CN-Ru(NH 3) 4py] · 6H 2O reveals that the Stark derived distances are ˜50% to ˜90% of the geometric separation of the metal centers. The differences result in an upward revision in the Hush delocalization parameter, c b2, and of the electronic coupling matrix element, H ab, relative to those parameters obtained exclusively from electronic absorption measurements. The revised parameters are compared to those, which are obtained via electrochemical techniques and found to be in only fair agreement. We conclude that the absorption/electroabsorption analysis likely yields a more reliable set of mixing and coupling parameters.

  10. Social relationships among adolescents as described in an electronic diary: a mixed methods study.

    PubMed

    Anttila, Katriina I; Anttila, Minna J; Kurki, Marjo H; Välimäki, Maritta A

    2017-01-01

    Social relationships among adolescents with mental disorders are demanding. Adolescents with depressive symptoms may have few relationships and have difficulties sharing their problems. Internet may offer reliable and easy to use tool to collect real-time information from adolescents. The aim of this study is to explore how adolescents describe their social relationships with an electronic diary. Mixed methods were used to obtain a broad picture of adolescents' social relationships with the data gathered from network maps and reflective texts written in an electronic diary. Adolescents who visited an outpatient clinic and used an intervention (N=70) designed for adolescents with signs of depression were invited to use the electronic diary; 29 did so. The quantitative data gathered in the electronic diary were summarized with descriptive statistics, and the qualitative data were categorized using a thematic analysis with an inductive approach. We found that social relationships among adolescents with signs of depression can vary greatly in regards to the number of existing relationships (from lacking to 21) and the quality of the relationships (from trustful to difficult). However, the relationships may change, and the adolescents are also willing to build up their social relationships. Professionals need to be aware of the diversity of adolescents' social relationships and their need for personalized support.

  11. Social relationships among adolescents as described in an electronic diary: a mixed methods study

    PubMed Central

    Anttila, Katriina I; Anttila, Minna J; Kurki, Marjo H; Välimäki, Maritta A

    2017-01-01

    Social relationships among adolescents with mental disorders are demanding. Adolescents with depressive symptoms may have few relationships and have difficulties sharing their problems. Internet may offer reliable and easy to use tool to collect real-time information from adolescents. The aim of this study is to explore how adolescents describe their social relationships with an electronic diary. Mixed methods were used to obtain a broad picture of adolescents’ social relationships with the data gathered from network maps and reflective texts written in an electronic diary. Adolescents who visited an outpatient clinic and used an intervention (N=70) designed for adolescents with signs of depression were invited to use the electronic diary; 29 did so. The quantitative data gathered in the electronic diary were summarized with descriptive statistics, and the qualitative data were categorized using a thematic analysis with an inductive approach. We found that social relationships among adolescents with signs of depression can vary greatly in regards to the number of existing relationships (from lacking to 21) and the quality of the relationships (from trustful to difficult). However, the relationships may change, and the adolescents are also willing to build up their social relationships. Professionals need to be aware of the diversity of adolescents’ social relationships and their need for personalized support. PMID:28280307

  12. Automated measurement of pressure injury through image processing.

    PubMed

    Li, Dan; Mathews, Carol

    2017-11-01

    To develop an image processing algorithm to automatically measure pressure injuries using electronic pressure injury images stored in nursing documentation. Photographing pressure injuries and storing the images in the electronic health record is standard practice in many hospitals. However, the manual measurement of pressure injury is time-consuming, challenging and subject to intra/inter-reader variability with complexities of the pressure injury and the clinical environment. A cross-sectional algorithm development study. A set of 32 pressure injury images were obtained from a western Pennsylvania hospital. First, we transformed the images from an RGB (i.e. red, green and blue) colour space to a YC b C r colour space to eliminate inferences from varying light conditions and skin colours. Second, a probability map, generated by a skin colour Gaussian model, guided the pressure injury segmentation process using the Support Vector Machine classifier. Third, after segmentation, the reference ruler - included in each of the images - enabled perspective transformation and determination of pressure injury size. Finally, two nurses independently measured those 32 pressure injury images, and intraclass correlation coefficient was calculated. An image processing algorithm was developed to automatically measure the size of pressure injuries. Both inter- and intra-rater analysis achieved good level reliability. Validation of the size measurement of the pressure injury (1) demonstrates that our image processing algorithm is a reliable approach to monitoring pressure injury progress through clinical pressure injury images and (2) offers new insight to pressure injury evaluation and documentation. Once our algorithm is further developed, clinicians can be provided with an objective, reliable and efficient computational tool for segmentation and measurement of pressure injuries. With this, clinicians will be able to more effectively monitor the healing process of pressure injuries. © 2017 John Wiley & Sons Ltd.

  13. Validation of an instrument to assess barriers to care-seeking for accidental bowel leakage in women: the BCABL questionnaire

    PubMed Central

    Brown, Heidi Wendell; Wise, Meg E.; Westenberg, Danielle; Schmuhl, Nicholas B.; Brezoczky, Kelly Lewis; Rogers, Rebecca G.; Constantine, Melissa L.

    2017-01-01

    Introduction and hypothesis Fewer than 30% of women with accidental bowel leakage (ABL) seek care, despite the existence of effective, minimally invasive therapies. We developed and validated a condition-specific instrument to assess barriers to care-seeking for ABL in women. Methods Adult women with ABL completed an electronic survey about condition severity, patient activation, previous care-seeking, and demographics. The Barriers to Care-seeking for Accidental Bowel Leakage (BCABL) instrument contained 42 potential items completed at baseline and again 2 weeks later. Paired t tests evaluated test–retest reliability. Factor analysis evaluated factor structure and guided item retention. Cronbach’s alpha evaluated internal consistency. Within and across factor item means generated a summary BCABL score used to evaluate scale validity with six external criterion measures. Results Among 1,677 click-throughs, 736 (44%) entered the survey; 95% of eligible female respondents (427 out of 458) provided complete data. Fifty-three percent of respondents had previously sought care for their ABL; median age was 62 years (range 27–89); mean Vaizey score was 12.8 (SD = 5.0), indicating moderate to severe ABL. Test–retest reliability was excellent for all items. Factor extraction via oblique rotation resulted in the final structure of 16 items in six domains, within which internal consistency was high. All six external criterion measures correlated significantly with BCABL score. Conclusions The BCABL questionnaire, with 16 items mapping to six domains, has excellent criterion validity and test–retest reliability when administered electronically in women with ABL. The BCABL can be used to identify care-seeking barriers for ABL in different populations, inform targeted interventions, and measure their effectiveness. PMID:28236039

  14. A new method of radio frequency links by coplanar coils for implantable medical devices.

    PubMed

    Xue, L; Hao, H W; Li, L; Ma, B Z

    2005-01-01

    A new method based on coplanar coils for the design of radio frequency links has been developed, to realize the communication between the programming wand and the implantable medical devices with shielding container simply and reliably. With the analysis of electronic and magnetic field theory, the communication model has been established and simulated, and the circuit has been designed and tested. The experimental results are consistent with the simulation fairly well. The voltage transfer ratio of the typical circuit with present parameters can reach as high as 0.02, which can fulfill the requirements of communication.

  15. Test-Retest Reliability of Pediatric Heart Rate Variability

    PubMed Central

    Weiner, Oren M.; McGrath, Jennifer J.

    2017-01-01

    Heart rate variability (HRV), an established index of autonomic cardiovascular modulation, is associated with health outcomes (e.g., obesity, diabetes) and mortality risk. Time- and frequency-domain HRV measures are commonly reported in longitudinal adult and pediatric studies of health. While test-retest reliability has been established among adults, less is known about the psychometric properties of HRV among infants, children, and adolescents. The objective was to conduct a meta-analysis of the test-retest reliability of time- and frequency-domain HRV measures from infancy to adolescence. Electronic searches (PubMed, PsycINFO; January 1970–December 2014) identified studies with nonclinical samples aged ≤ 18 years; ≥ 2 baseline HRV recordings separated by ≥ 1 day; and sufficient data for effect size computation. Forty-nine studies (N = 5,170) met inclusion criteria. Methodological variables coded included factors relevant to study protocol, sample characteristics, electrocardiogram (ECG) signal acquisition and preprocessing, and HRV analytical decisions. Fisher’s Z was derived as the common effect size. Analyses were age-stratified (infant/toddler < 5 years, n = 3,329; child/adolescent 5–18 years, n = 1,841) due to marked methodological differences across the pediatric literature. Meta-analytic results revealed HRV demonstrated moderate reliability; child/adolescent studies (Z = 0.62, r = 0.55) had significantly higher reliability than infant/toddler studies (Z = 0.42, r = 0.40). Relative to other reported measures, HF exhibited the highest reliability among infant/toddler studies (Z = 0.42, r = 0.40), while rMSSD exhibited the highest reliability among child/adolescent studies (Z = 1.00, r = 0.76). Moderator analyses indicated greater reliability with shorter test-retest interval length, reported exclusion criteria based on medical illness/condition, lower proportion of males, prerecording acclimatization period, and longer recording duration; differences were noted across age groups. HRV is reliable among pediatric samples. Reliability is sensitive to pertinent methodological decisions that require careful consideration by the researcher. Limited methodological reporting precluded several a priori moderator analyses. Suggestions for future research, including standards specified by Task Force Guidelines, are discussed. PMID:29307951

  16. Solid Rocket Booster Integrated Electronic Assemblies Support

    NASA Technical Reports Server (NTRS)

    Blanche, James

    2001-01-01

    The paper discusses the following: assess the impact of aging and usage on SRB Forward and Aft Integrated Electronic Assemblies (IEA's); d3etermine the relative position of the IEA's on their expected reliability curves; provide recommendations, with supporting rationale, for any upgrades necessary to maintain reliability and logistic supportability through the year 2020; if upgrades are recommended the team will define a roadmap for the design and implementation of the upgrade; assess the other reusable boxes on the SRB to determine if the screening tests between flights are adequate; and assess the other reusable boxes on the SRB to determine if they are wearing out.

  17. Full 3D opto-electronic simulation tool for nanotextured solar cells (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Michallon, Jérôme; Collin, Stéphane

    2017-04-01

    Increasing efforts on the photovoltaics research have recently been devoted to material savings, leading to the emergence of new designs based on nanotextured and nanowire-based solar cells. The use of small absorber volumes, light-trapping nanostructures and unconventional carrier collection schemes (radial nanowire junctions, point contacts in planar structures,…) increases the impact of surfaces recombination and induces homogeneity in the photogenerated carrier concentrations. The investigation of their impacts on the device performances need to be addressed using full 3D coupled opto-electrical modeling. In this context, we have developed a new tool for full 3D opto-electrical simulation using the most advanced optical and electrical simulation techniques. We will present an overview of its simulation capabilities and the key issues that have been solved to make it fully operational and reliable. We will provide various examples of opto-electronic simulation of (i) nanostructured solar cells with localized contacts and (ii) nanowire solar cells. We will also show how opto-electronic simulation can be used to simulate light- and electron-beam induced current (LBIC/EBIC) experiments, targeting quantitative analysis of the passivation properties of surfaces.

  18. Plastic packaged microcircuits: Quality, reliability, and cost issues

    NASA Astrophysics Data System (ADS)

    Pecht, Michael G.; Agarwal, Rakesh; Quearry, Dan

    1993-12-01

    Plastic encapsulated microcircuits (PEMs) find their main application in commercial and telecommunication electronics. The advantages of PEMs in cost, size, weight, performance, and market lead-time, have attracted 97% of the market share of worldwide microcircuit sales. However, PEMs have always been resisted in US Government and military applications due to the perception that PEM reliability is low. This paper surveys plastic packaging with respect to the issues of reliability, market lead-time, performance, cost, and weight as a means to guide part-selection and system-design.

  19. [SCREENING OF NUTRITIONAL STATUS AMONG ELDERLY PEOPLE AT FAMILY MEDICINE].

    PubMed

    Račić, M; Ivković, N; Kusmuk, S

    2015-11-01

    The prevalence of malnutrition in elderly is high. Malnutrition or risk of malnutrition can be detected by use of nutritional screening or assessment tools. This systematic review aimed to identify tools that would be reliable, valid, sensitive and specific for nutritional status screening in patients older than 65 at family medicine. The review was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Studies were retrieved using MEDLINE (via Ovid), PubMed and Cochrane Library electronic databases and by manual searching of relevant articles listed in reference list of key publications. The electronic databases were searched using defined key words adapted to each database and using MESH terms. Manual revision of reviews and original articles was performed using Electronic Journals Library. Included studies involved development and validation of screening tools in the community-dwelling elderly population. The tools, subjected to validity and reliability testing for use in the community-dwelling elderly population were Mini Nutritional Assessment (MNA), Mini Nutritional Assessment-Short Form (MNA-SF), Nutrition Screening Initiative (NSI), which includes DETERMINE list, Level I and II Screen, Seniors in the Community: Risk Evaluation for Eating, and Nutrition (SCREEN I and SCREEN II), Subjective Global Assessment (SGA), Nutritional Risk Index (NRI), and Malaysian and South African tool. MNA and MNA-SF appear to have highest reliability and validity for screening of community-dwelling elderly, while the reliability and validity of SCREEN II are good. The authors conclude that whilst several tools have been developed, most have not undergone extensive testing to demonstrate their ability to identify nutritional risk. MNA and MNA-SF have the highest reliability and validity for screening of nutritional status in the community-dwelling elderly, and the reliability and validity of SCREEN II are satisfactory. These instruments also contain all three nutritional status indicators and are practical for use in family medicine. However, the gold standard for screening cannot be set because testing of reliability and continuous validation in the study with a higher level of evidence need to be conducted in family medicine.

  20. The Trojan Lifetime Champions Health Survey: Development, Validity, and Reliability

    PubMed Central

    Sorenson, Shawn C.; Romano, Russell; Scholefield, Robin M.; Schroeder, E. Todd; Azen, Stanley P.; Salem, George J.

    2015-01-01

    Context Self-report questionnaires are an important method of evaluating lifespan health, exercise, and health-related quality of life (HRQL) outcomes among elite, competitive athletes. Few instruments, however, have undergone formal characterization of their psychometric properties within this population. Objective To evaluate the validity and reliability of a novel health and exercise questionnaire, the Trojan Lifetime Champions (TLC) Health Survey. Design Descriptive laboratory study. Setting A large National Collegiate Athletic Association Division I university. Patients or Other Participants A total of 63 university alumni (age range, 24 to 84 years), including former varsity collegiate athletes and a control group of nonathletes. Intervention(s) Participants completed the TLC Health Survey twice at a mean interval of 23 days with randomization to the paper or electronic version of the instrument. Main Outcome Measure(s) Content validity, feasibility of administration, test-retest reliability, parallel-form reliability between paper and electronic forms, and estimates of systematic and typical error versus differences of clinical interest were assessed across a broad range of health, exercise, and HRQL measures. Results Correlation coefficients, including intraclass correlation coefficients (ICCs) for continuous variables and κ agreement statistics for ordinal variables, for test-retest reliability averaged 0.86, 0.90, 0.80, and 0.74 for HRQL, lifetime health, recent health, and exercise variables, respectively. Correlation coefficients, again ICCs and κ, for parallel-form reliability (ie, equivalence) between paper and electronic versions averaged 0.90, 0.85, 0.85, and 0.81 for HRQL, lifetime health, recent health, and exercise variables, respectively. Typical measurement error was less than the a priori thresholds of clinical interest, and we found minimal evidence of systematic test-retest error. We found strong evidence of content validity, convergent construct validity with the Short-Form 12 Version 2 HRQL instrument, and feasibility of administration in an elite, competitive athletic population. Conclusions These data suggest that the TLC Health Survey is a valid and reliable instrument for assessing lifetime and recent health, exercise, and HRQL, among elite competitive athletes. Generalizability of the instrument may be enhanced by additional, larger-scale studies in diverse populations. PMID:25611315

  1. Computer-Based and Paper-Based Measurement of Recognition Performance

    DTIC Science & Technology

    1989-03-01

    domains (e.g., ship silhouettes, electronic schemata, human anatomy ) to ascertain the universality of the validity and reliability results...specific graphic 4 database (e.g., ship silhouettes, human anatomy , electronic circuits, topography), con- tributes to its wide applicability. The game, then...seek implementation of FLASH and PICTURE in other content areas or subject-matter domains (e.g., ship silhouettes, electronic schemata, human anatomy ) to

  2. Single-state electronic ballast with dimming feature and unity power factor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, T.F.; Yu, T.H.; Chiang, M.C.

    1998-05-01

    Analysis, design, and practical consideration of a single-stage electronic ballast with dimming feature and unity power factor are presented in this paper. The proposed single-stage ballast is the combination of a boost converter and a half-bridge series-resonant parallel-loaded inverter. The boost semistage working in the discontinuous conduction mode functions as a power factor corrector and the inverter semistage operated above resonance are employed to ballast the lamp. Replacing the lamp with the plasma model, analysis of the ballast is fulfilled. The dimming feature is carried out by pulse-width modulation (PWM) and variable-frequency controls simultaneously. The proposed single-stage ballast is suitablemore » for applications with moderate power level and low-line voltage while requiring a high-output voltage. It can save a controller, an active switch and its driver, reduce size, and possibly increase system reliability while requiring two additional diodes over a conventional two-stage system. A prototype was implemented to verify the theoretical discussion. The hardware measurements have shown that the desired performance can be achieved feasibly.« less

  3. Study of Solid-State Diffusion of Bi in Polycrystalline Sn Using Electron Probe Microanalysis

    NASA Astrophysics Data System (ADS)

    Delhaise, André M.; Perovic, Doug D.

    2018-03-01

    Current lead-free solders such as SAC305 exhibit degradation in microstructure, properties, and reliability. Current third-generation alloys containing bismuth (Bi) demonstrate preservation of strength after aging; this is accompanied by homogenization of the Bi precipitates in the tin (Sn) matrix, driven via solid-state diffusion. This study quantifies the diffusion of Bi in Sn. Diffusion couples were prepared by mating together polished samples of pure Sn and Bi. Couples were annealed at one of three temperatures, viz. 85°C for 7 days, 100°C for 2 days, or 125°C for 1 day. After cross-sectioning the couples to examine the diffusion microstructure and grain size, elemental analysis was performed using electron probe microanalysis. For this study, it was assumed that the diffusivity of Bi in Sn is concentration dependent, therefore inverse methods were used to solve Fick's non-steady-state diffusion equation. In addition, Darken analysis was used to extract the impurity diffusivity of Bi in Sn at each temperature, allowing estimation of the Arrhenius parameters D 0 and k A.

  4. Effective electromagnetic interference shielding for electronic equipment.

    PubMed

    Sheedy, Billy

    2003-11-01

    With the development of tough, durable compounds, plastics are the preferred material for electronic equipment housings. The availability of economical, effective coating materials that can give plastics some of the desirable properties lost in the switch from metals are helping to allow the design of reliable medical equipment.

  5. Electronic circuit detects left ventricular ejection events in cardiovascular system

    NASA Technical Reports Server (NTRS)

    Gebben, V. D.; Webb, J. A., Jr.

    1972-01-01

    Electronic circuit processes arterial blood pressure waveform to produce discrete signals that coincide with beginning and end of left ventricular ejection. Output signals provide timing signals for computers that monitor cardiovascular systems. Circuit operates reliably for heart rates between 50 and 200 beats per minute.

  6. Analyzing Responses of Chemical Sensor Arrays

    NASA Technical Reports Server (NTRS)

    Zhou, Hanying

    2007-01-01

    NASA is developing a third-generation electronic nose (ENose) capable of continuous monitoring of the International Space Station s cabin atmosphere for specific, harmful airborne contaminants. Previous generations of the ENose have been described in prior NASA Tech Briefs issues. Sensor selection is critical in both (prefabrication) sensor material selection and (post-fabrication) data analysis of the ENose, which detects several analytes that are difficult to detect, or that are at very low concentration ranges. Existing sensor selection approaches usually include limited statistical measures, where selectivity is more important but reliability and sensitivity are not of concern. When reliability and sensitivity can be major limiting factors in detecting target compounds reliably, the existing approach is not able to provide meaningful selection that will actually improve data analysis results. The approach and software reported here consider more statistical measures (factors) than existing approaches for a similar purpose. The result is a more balanced and robust sensor selection from a less than ideal sensor array. The software offers quick, flexible, optimal sensor selection and weighting for a variety of purposes without a time-consuming, iterative search by performing sensor calibrations to a known linear or nonlinear model, evaluating the individual sensor s statistics, scoring the individual sensor s overall performance, finding the best sensor array size to maximize class separation, finding optimal weights for the remaining sensor array, estimating limits of detection for the target compounds, evaluating fingerprint distance between group pairs, and finding the best event-detecting sensors.

  7. An innovative and comprehensive technique to evaluate different measures of medication adherence: The network meta-analysis.

    PubMed

    Tonin, Fernanda S; Wiecek, Elyssa; Torres-Robles, Andrea; Pontarolo, Roberto; Benrimoj, Shalom Charlie I; Fernandez-Llimos, Fernando; Garcia-Cardenas, Victoria

    2018-05-19

    Poor medication adherence is associated with adverse health outcomes and higher costs of care. However, inconsistencies in the assessment of adherence are found in the literature. To evaluate the effect of different measures of adherence in the comparative effectiveness of complex interventions to enhance patients' adherence to prescribed medications. A systematic review with network meta-analysis was performed. Electronic searches for relevant pairwise meta-analysis including trials of interventions that aimed to improve medication adherence were performed in PubMed. Data extraction was conducted with eligible trials evaluating short-period adherence follow-up (until 3 months) using any measure of adherence: self-report, pill count, or MEMS (medication event monitoring system). To standardize the results obtained with these different measures, an overall composite measure and an objective composite measure were also calculated. Network meta-analyses for each measure of adherence were built. Rank order and surface under the cumulative ranking curve analyses (SUCRA) were performed. Ninety-one trials were included in the network meta-analyses. The five network meta-analyses demonstrated robustness and reliability. Results obtained for all measures of adherence were similar across them and to both composite measures. For both composite measures, interventions comprising economic + technical components were the best option (90% of probability in SUCRA analysis) with statistical superiority against almost all other interventions and against standard care (odds ratio with 95% credibility interval ranging from 0.09 to 0.25 [0.02, 0.98]). The use of network meta-analysis was reliable to compare different measures of adherence of complex interventions in short-periods follow-up. Analyses with longer follow-up periods are needed to confirm these results. Different measures of adherence produced similar results. The use of composite measures revealed reliable alternatives to establish a broader and more detailed picture of adherence. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Wind energy Computerized Maintenance Management System (CMMS) : data collection recommendations for reliability analysis.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, Valerie A.; Ogilvie, Alistair B.

    2012-01-01

    This report addresses the general data requirements for reliability analysis of fielded wind turbines and other wind plant equipment. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific data recommendations for a Computerized Maintenance Management System (CMMS) to support automated analysis. This data collection recommendations report was written by Sandia National Laboratories to address the general data requirements for reliability analysis of operating wind turbines. This report is intended to help develop a basic understanding of the data needed for reliability analysis frommore » a Computerized Maintenance Management System (CMMS) and other data systems. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific recommendations for a CMMS to support automated analysis. Though written for reliability analysis of wind turbines, much of the information is applicable to a wider variety of equipment and analysis and reporting needs. The 'Motivation' section of this report provides a rationale for collecting and analyzing field data for reliability analysis. The benefits of this type of effort can include increased energy delivered, decreased operating costs, enhanced preventive maintenance schedules, solutions to issues with the largest payback, and identification of early failure indicators.« less

  9. NASA-DoD Lead-Free Electronics Project. DRAFT Joint Test Report

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt

    2011-01-01

    The use of conventional tin-lead (SnPb) in circuit board manufacturing is under ever-increasing political scrutiny due to increasing regulations concerning lead. The "Restriction of Hazardous Substances" (RoHS) directive enacted by the European Union (EU) and a pact between the United States National Electronics Manufacturing Initiative (NEMI), Europe's Soldertec at Tin Technology Ltd. and the Japan Electronics and Information Technology Industries Association (JEITA) are just two examples where worldwide legislative actions and partnerships/agreements are affecting the electronics industry. As a result, many global commercial-grade electronic component suppliers are initiating efforts to transition to lead-free (Pb-free) in order to retain their worldwide market. Pb-free components are likely to find their way into the inventory of aerospace or military assembly processes under current government acquisition reform initiatives. Inventories "contaminated" by Pb-free will result in increased risks associated with the manufacturing, product reliability, and subsequent repair of aerospace and military electronic systems. Although electronics for military and aerospace applications are not included in the RoHS legislation, engineers are beginning to find that the commercial industry's move towards RoHS compliance has affected their supply chain and changed their parts. Most parts suppliers plan to phase out their non-compliant, leaded production and many have already done so. As a result, the ability to find leaded components is getting harder and harder. Some buyers are now attempting to acquire the remaining SnPb inventory, if it's not already obsolete. Original Equipment Manufacturers (OEMs), depots, and support contractors have to be prepared to deal with an electronics supply chain that increasingly provides more and more parts with Pb-free finishes-some labeled no differently than their Pb counterparts-while at the same time providing the traditional Pb parts. The longer the transition period, the greater the likelihood of Pb-free parts inadvertently being mixed with Pb parts and ending up on what are supposed to be Pb systems. As a result, OEMs, depots, and support contractors need to take action now to either abate the influx of Pb-free parts, or accept it and deal with the likely interim consequences of reduced reliability due to a wide variety of matters, such as Pb contamination, high temperature incompatibility, and tin whiskering. Allowance of Pb-free components produces one of the greatest risks to the reliability of a weapon system. This is due to new and poorly understood failure mechanisms, as well as unknown long-term reliability. If the decision is made to consciously allow Pb-free solder and component finishes into SnPb electronics, additional effort (and cost) will be required to make the significant number of changes to drawings and task order procedures. This project is a follow-on effort to the Joint Council on Aging Aircraft/Joint Group on Pollution Prevention (JCAA/JG-PP) Pb-free Solder Project which was the first group to test the reliability of Pb-free solder joints against the requirements of the aerospace and military community.

  10. JTEC Panel report on electronic manufacturing and packaging in Japan

    NASA Technical Reports Server (NTRS)

    Kelly, Michael J.; Boulton, William R. (Editor); Kukowski, John; Meieran, Gene; Pecht, Michael; Peeples, John; Tummala, Rao; Dehaemer, Michael J.; Holdridge, Geoff (Editor); Gamota, George

    1995-01-01

    This report summarizes the status of electronic manufacturing and packaging technology in Japan in comparison to that in the United States, and its impact on competition in electronic manufacturing in general. In addition to electronic manufacturing technologies, the report covers technology and manufacturing infrastructure, electronics manufacturing and assembly, quality assurance and reliability in the Japanese electronics industry, and successful product realization strategies. The panel found that Japan leads the United States in almost every electronics packaging technology. Japan clearly has achieved a strategic advantage in electronics production and process technologies. Panel members believe that Japanese competitors could be leading U.S. firms by as much as a decade in some electronics process technologies.

  11. Transfer coefficients in ultracold strongly coupled plasma

    NASA Astrophysics Data System (ADS)

    Bobrov, A. A.; Vorob'ev, V. S.; Zelener, B. V.

    2018-03-01

    We use both analytical and molecular dynamic methods for electron transfer coefficients in an ultracold plasma when its temperature is small and the coupling parameter characterizing the interaction of electrons and ions exceeds unity. For these conditions, we use the approach of nearest neighbor to determine the average electron (ion) diffusion coefficient and to calculate other electron transfer coefficients (viscosity and electrical and thermal conductivities). Molecular dynamics simulations produce electronic and ionic diffusion coefficients, confirming the reliability of these results. The results compare favorably with experimental and numerical data from earlier studies.

  12. Electron Source Brightness and Illumination Semi-Angle Distribution Measurement in a Transmission Electron Microscope.

    PubMed

    Börrnert, Felix; Renner, Julian; Kaiser, Ute

    2018-05-21

    The electron source brightness is an important parameter in an electron microscope. Reliable and easy brightness measurement routes are not easily found. A determination method for the illumination semi-angle distribution in transmission electron microscopy is even less well documented. Herein, we report a simple measurement route for both entities and demonstrate it on a state-of-the-art instrument. The reduced axial brightness of the FEI X-FEG with a monochromator was determined to be larger than 108 A/(m2 sr V).

  13. POF-IMU sensor system: A fusion between inertial measurement units and POF sensors for low-cost and highly reliable systems

    NASA Astrophysics Data System (ADS)

    Leal-Junior, Arnaldo G.; Vargas-Valencia, Laura; dos Santos, Wilian M.; Schneider, Felipe B. A.; Siqueira, Adriano A. G.; Pontes, Maria José; Frizera, Anselmo

    2018-07-01

    This paper presents a low cost and highly reliable system for angle measurement based on a sensor fusion between inertial and fiber optic sensors. The system consists of the sensor fusion through Kalman filter of two inertial measurement units (IMUs) and an intensity variation-based polymer optical fiber (POF) curvature sensor. In addition, the IMU was applied as a reference for a compensation technique of POF curvature sensor hysteresis. The proposed system was applied on the knee angle measurement of a lower limb exoskeleton in flexion/extension cycles and in gait analysis. Results show the accuracy of the system, where the Root Mean Square Error (RMSE) between the POF-IMU sensor system and the encoder was below 4° in the worst case and about 1° in the best case. Then, the POF-IMU sensor system was evaluated as a wearable sensor for knee joint angle assessment without the exoskeleton, where its suitability for this purpose was demonstrated. The results obtained in this paper pave the way for future applications of sensor fusion between electronic and fiber optic sensors in movement analysis.

  14. MEMS reliability: coming of age

    NASA Astrophysics Data System (ADS)

    Douglass, Michael R.

    2008-02-01

    In today's high-volume semiconductor world, one could easily take reliability for granted. As the MOEMS/MEMS industry continues to establish itself as a viable alternative to conventional manufacturing in the macro world, reliability can be of high concern. Currently, there are several emerging market opportunities in which MOEMS/MEMS is gaining a foothold. Markets such as mobile media, consumer electronics, biomedical devices, and homeland security are all showing great interest in microfabricated products. At the same time, these markets are among the most demanding when it comes to reliability assurance. To be successful, each company developing a MOEMS/MEMS device must consider reliability on an equal footing with cost, performance and manufacturability. What can this maturing industry learn from the successful development of DLP technology, air bag accelerometers and inkjet printheads? This paper discusses some basic reliability principles which any MOEMS/MEMS device development must use. Examples from the commercially successful and highly reliable Digital Micromirror Device complement the discussion.

  15. Development of Nonelectronic Part Cyclic Failure Rates

    DTIC Science & Technology

    1977-12-01

    Schilling, W. A., "The User-Oriented Connector," Microwave Journal, Octcber 1976 40. Schneider, C., "Military Relay Reliability," Bell Telephone...polyimide B Diallyl phthalate, melamine , -55 to 200 fluorosilicone, silicone rubber, polysulfone, epoxy resin C Polytetrafluoroethylene (teflon) -55 to 125...propagation, solid state sciences, microwave physics and electronic reliability, maintainabilitg andcompatibility. .,% -UT104, , 8. g z

  16. Flash Memory Reliability: Read, Program, and Erase Latency Versus Endurance Cycling

    NASA Technical Reports Server (NTRS)

    Heidecker, Jason

    2010-01-01

    This report documents the efforts and results of the fiscal year (FY) 2010 NASA Electronic Parts and Packaging Program (NEPP) task for nonvolatile memory (NVM) reliability. This year's focus was to measure latency (read, program, and erase) of NAND Flash memories and determine how these parameters drift with erase/program/read endurance cycling.

  17. 77 FR 39858 - Revisions to Electric Reliability Organization Definition of Bulk Electric System and Rules of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-05

    ...'' as used in the NERC Glossary. \\25\\ Id. at 15. \\26\\ Id. at 16. 16. NERC also explains that, while the...: Through http://www.ferc.gov . Documents created electronically using word processing software should be...'s Glossary of Terms Used in Reliability Standards (NERC Glossary) developed by the North American...

  18. Reliability Analysis and Reliability-Based Design Optimization of Circular Composite Cylinders Under Axial Compression

    NASA Technical Reports Server (NTRS)

    Rais-Rohani, Masoud

    2001-01-01

    This report describes the preliminary results of an investigation on component reliability analysis and reliability-based design optimization of thin-walled circular composite cylinders with average diameter and average length of 15 inches. Structural reliability is based on axial buckling strength of the cylinder. Both Monte Carlo simulation and First Order Reliability Method are considered for reliability analysis with the latter incorporated into the reliability-based structural optimization problem. To improve the efficiency of reliability sensitivity analysis and design optimization solution, the buckling strength of the cylinder is estimated using a second-order response surface model. The sensitivity of the reliability index with respect to the mean and standard deviation of each random variable is calculated and compared. The reliability index is found to be extremely sensitive to the applied load and elastic modulus of the material in the fiber direction. The cylinder diameter was found to have the third highest impact on the reliability index. Also the uncertainty in the applied load, captured by examining different values for its coefficient of variation, is found to have a large influence on cylinder reliability. The optimization problem for minimum weight is solved subject to a design constraint on element reliability index. The methodology, solution procedure and optimization results are included in this report.

  19. Interactive learning media based on flash for basic electronic engineering development for SMK Negeri 1 Driyorejo - Gresik

    NASA Astrophysics Data System (ADS)

    Mandigo Anggana Raras, Gustav

    2018-04-01

    This research aims to produce a product in the form of flash based interactive learning media on a basic electronic engineering subject that reliable to be used and to know students’ responses about the media. The target of this research is X-TEI 1 class at SMK Negeri 1 Driyorejo – Gresik. The method used in this study is R&D that has been limited into seven stages only (1) potential and problems, (2) data collection, (3) product design, (4) product validation, (5) product revision, (6) field test, and (7) analysis and writing. The obtained result is interactive learning media named MELDASH. Validation process used to produce a valid interactive learning media. The result of media validation state that the interactive learning media has a 90.83% rating. Students’ responses to this interactive learning media is really good with 88.89% rating.

  20. A Monte Carlo software for the 1-dimensional simulation of IBIC experiments

    NASA Astrophysics Data System (ADS)

    Forneris, J.; Jakšić, M.; Pastuović, Ž.; Vittone, E.

    2014-08-01

    The ion beam induced charge (IBIC) microscopy is a valuable tool for the analysis of the electronic properties of semiconductors. In this work, a recently developed Monte Carlo approach for the simulation of IBIC experiments is presented along with a self-standing software equipped with graphical user interface. The method is based on the probabilistic interpretation of the excess charge carrier continuity equations and it offers to the end-user the full control not only of the physical properties ruling the induced charge formation mechanism (i.e., mobility, lifetime, electrostatics, device's geometry), but also of the relevant experimental conditions (ionization profiles, beam dispersion, electronic noise) affecting the measurement of the IBIC pulses. Moreover, the software implements a novel model for the quantitative evaluation of the radiation damage effects on the charge collection efficiency degradation of ion-beam-irradiated devices. The reliability of the model implementation is then validated against a benchmark IBIC experiment.

  1. INTEGRAL/SPI Limits on Electron-Positron Annihilation Radiation from the Galactic Plane

    NASA Technical Reports Server (NTRS)

    Teegarden, B. J.; Watanabe, K.; Jean, P.; Knoedlseder, J.; Lonjou, V.; Roques, J. P.; Skinner, G. K.; vonBallmoos, P.; Weidenspointner, G.; Bazzano, A.

    2005-01-01

    The center of our Galaxy is a known strong source of electron-positron 511- keV annihilation radiation. Thus far, however, there have been no reliable detections of annihilation radiation outside of the central radian of our Galaxy. One of the primary objectives of the INTEGRAL (INTErnational Gamma-RAy Astrophysics Laboratory) mission, launched in Oct. 2002, is the detailed study of this radiation. The Spectrometer on INTEGRAL (SPI) is a high resolution coded-aperture gamma-ray telescope with an unprecedented combination of sensitivity, angular resolution and energy resolution. We report results from the first 10 months of observation. During this period a significant fraction of the observing time was spent in or near the Galactic Plane. No positive annihilation flux was detected outside of the central region (|l| greater than 40 degrees) of our Galaxy. In this paper we describe the observations and data analysis methods and give limits on the 511-keV flux.

  2. Bridging informatics and implementation science: evaluating a framework to assess electronic health record implementations in community settings.

    PubMed

    Richardson, Joshua E; Abramson, Erika L; Pfoh, Elizabeth R; Kaushal, Rainu

    2012-01-01

    Effective electronic health record (EHR) implementations in community settings are critical to promoting safe and reliable EHR use as well as mitigating provider dissatisfaction that often results. The implementation challenge is compounded given the scale and scope of EHR installations that are occurring and will continue to occur over the next five years. However, when compared to EHR evaluations relatively few biomedical informatics researchers have published on evaluating EHR implementations. Fewer still have evaluated EHR implementations in community settings. We report on the methods we used to achieve a novel application of an implementation science framework in informatics to qualitatively evaluate community-based EHR implementations. We briefly provide an overview of the implementation science framework, our methods for adapting it to informatics, the effects the framework had on our qualitative methods of inquiry and analysis, and discuss its potential value for informatics research.

  3. Electronic Sentinel Surveillance of Influenza-like Illness. Experience from a pilot study in New Zealand.

    PubMed

    Adnan, Mehnaz; Peterkin, Donald; Lopez, Liza; Mackereth, Graham

    2017-02-01

    Electronic reporting of Influenza-like illness (eILI) from primary care was implemented and evaluated in three general medical practices in New Zealand during May to September 2015. To measure the uptake of eILI and to identify the system's strength and limitations. Analysis of transactional data from the eILI system; comparative study of influenza-like illness cases reported using manual methods and eILI; questionnaire administered to clinical and operational stakeholders. Over the study period 66% of total ILI cases were reported using eILI. Reporting timeliness improved significantly compared to manual reporting with an average of 24 minutes from submission by the clinician to processing in the national database. Users found the system to be user-friendly. eILI assists clinicians to report ILI cases to public health authorities within a stipulated time period and is associated with faster, more reliable and improved information transfer.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liakh, Dmitry I

    While the formalism of multiresolution analysis (MRA), based on wavelets and adaptive integral representations of operators, is actively progressing in electronic structure theory (mostly on the independent-particle level and, recently, second-order perturbation theory), the concepts of multiresolution and adaptivity can also be utilized within the traditional formulation of correlated (many-particle) theory which is based on second quantization and the corresponding (generally nonorthogonal) tensor algebra. In this paper, we present a formalism called scale-adaptive tensor algebra (SATA) which exploits an adaptive representation of tensors of many-body operators via the local adjustment of the basis set quality. Given a series of locallymore » supported fragment bases of a progressively lower quality, we formulate the explicit rules for tensor algebra operations dealing with adaptively resolved tensor operands. The formalism suggested is expected to enhance the applicability and reliability of local correlated many-body methods of electronic structure theory, especially those directly based on atomic orbitals (or any other localized basis functions).« less

  5. Physics of thermal transport and increased electron temperature turbulence in the edge pedestal of ELM-free, H-mode regimes on DIII-D

    NASA Astrophysics Data System (ADS)

    Sung, Choongki

    2017-10-01

    It has been observed, for the first time, that suppression of Edge Localized Modes (ELMs) in tokamak plasmas is accompanied by an increase in electron temperature turbulence. A correlation electron cyclotron emission technique has been utilized to quantify the observed increase: 40% increase in Quiescent H-mode (QH-mode) and 70% increase in 3D field ELM suppressed H-mode. Since reliable ELM-free H-mode operation is essential for future burning plasma experiments, it is crucial to develop a validated predictive capability for these plasmas. Linear stability analysis using TGLF has provided an explanation for the observations and has indicated that the underlying physical mechanisms are different in the two regimes. In QH-mode, profile gradients and the associated linear growth rate are decreased compared to ELMing H-mode. However, the ExB shearing rate is reduced by an even greater factor such that turbulent transport is no longer suppressed by flow shear. In contrast, during 3D field ELM suppressed H-mode, gradients are increased and TGLF predicts that a large increase in linear growth rate is primarily responsible for the increased turbulence. Power balance analysis using ONETWO is also consistent with the changes in electron thermal transport being due to the increased turbulence. These new findings are significant since they i) provide a physics explanation of these changes via TGLF analysis and enable validation of the model in the key pedestal region, and ii) support the hypothesis that turbulent transport partially replaces ELM-dominated transport during ELM-free operation. These results form a basis to develop a predictive understanding of pedestal regulation in ELM suppressed regimes. Supported by the US DOE under DE-FG02-08ER54984, DE-FC02-04ER54698.

  6. Users Guide on Scaled CMOS Reliability: NASA Electronic Parts and Packaging (NEPP) Program Office of Safety and Mission Assurance

    NASA Technical Reports Server (NTRS)

    White, Mark; Cooper, Mark; Johnston, Allan

    2011-01-01

    Reliability of advanced CMOS technology is a complex problem that is usually addressed from the standpoint of specific failure mechanisms rather than overall reliability of a finished microcircuit. A detailed treatment of CMOS reliability in scaled devices can be found in Ref. 1; it should be consulted for a more thorough discussion. The present document provides a more concise treatment of the scaled CMOS reliability problem, emphasizing differences in the recommended approach for these advanced devices compared to that of less aggressively scaled devices. It includes specific recommendations that can be used by flight projects that use advanced CMOS. The primary emphasis is on conventional memories, microprocessors, and related devices.

  7. Atmosphere to Electrons: Enabling the Wind Plant of Tomorrow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Office of Energy Efficiency and Renewable Energy

    2015-11-01

    The U.S. Department of Energy’s Atmosphere to Electrons research initiative is focused on improving the performance and reliability of wind plants by establishing an unprecedented understanding of how the Earth’s atmosphere interacts with the wind plants and developing innovative technologies to maximize energy extraction from the wind.

  8. Developing Individualized IEP Goals in the Age of Technology: Quality Challenges and Solutions

    ERIC Educational Resources Information Center

    More, Cori M.; Hart Barnett, Juliet E.

    2014-01-01

    Many school districts have adopted commercially available software or templates for electronic Individualized Education Program (IEP) development. These programs have useful features that allow Individualized Education Programs to be electronically developed and reliably stored for each student. Although the program features are designed to…

  9. Application of the BEf-scaling approach to electron impact excitation of diople-allowed electronic states in molecules

    NASA Astrophysics Data System (ADS)

    Brunger, M. J.; Thorn, P. A.; Campbell, L.; Kato, H.; Kawahara, H.; Hoshino, M.; Tanaka, H.; Kim, Y.-K.

    2008-05-01

    We consider the efficacy of the BEf-scaling approach, in calculating reliable integral cross sections for electron impact excitation of dipole-allowed electronic states in molecules. We will demonstrate, using specific examples in H2, CO and H2O, that this relatively simple procedure can generate quite accurate integral cross sections which compare well with available experimental data. Finally, we will briefly consider the ramifications of this to atmospheric and other types of modelling studies.

  10. Exploratory Development on an Electronic Safing and Arming Device for Ordnance Fuzing

    DTIC Science & Technology

    1983-02-01

    to the bridges. Two units were subjected to MIL-STD-331, Test 101, Jolt. The EBMs were placed in the S & A cavity of an M739 fuze body for this test...of the program was to explore a concept for a safe, reliable, general purpose, low cost, electronic, A ’ zsafing and arming ( S & A ) system for use in...breadboard model hardware of the electronic S & A device. The electronic S & A devicu consists of an explosive barrier moduls (EBM) explosive train

  11. Electron Transport Modeling of Molecular Nanoscale Bridges Used in Energy Conversion Schemes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunietz, Barry D

    2016-08-09

    The goal of the research program is to reliably describe electron transport and transfer processes at the molecular level. Such insight is essential for improving molecular applications of solar and thermal energy conversion. We develop electronic structure models to study (1) photoinduced electron transfer and transport processes in organic semiconducting materials, and (2) charge and heat transport through molecular bridges. We seek fundamental understanding of key processes, which lead to design new experiments and ultimately to achieve systems with improved properties.

  12. Overcoming the Challenges of Unstructured Data in Multisite, Electronic Medical Record-based Abstraction.

    PubMed

    Polnaszek, Brock; Gilmore-Bykovskyi, Andrea; Hovanes, Melissa; Roiland, Rachel; Ferguson, Patrick; Brown, Roger; Kind, Amy J H

    2016-10-01

    Unstructured data encountered during retrospective electronic medical record (EMR) abstraction has routinely been identified as challenging to reliably abstract, as these data are often recorded as free text, without limitations to format or structure. There is increased interest in reliably abstracting this type of data given its prominent role in care coordination and communication, yet limited methodological guidance exists. As standard abstraction approaches resulted in substandard data reliability for unstructured data elements collected as part of a multisite, retrospective EMR study of hospital discharge communication quality, our goal was to develop, apply and examine the utility of a phase-based approach to reliably abstract unstructured data. This approach is examined using the specific example of discharge communication for warfarin management. We adopted a "fit-for-use" framework to guide the development and evaluation of abstraction methods using a 4-step, phase-based approach including (1) team building; (2) identification of challenges; (3) adaptation of abstraction methods; and (4) systematic data quality monitoring. Unstructured data elements were the focus of this study, including elements communicating steps in warfarin management (eg, warfarin initiation) and medical follow-up (eg, timeframe for follow-up). After implementation of the phase-based approach, interrater reliability for all unstructured data elements demonstrated κ's of ≥0.89-an average increase of +0.25 for each unstructured data element. As compared with standard abstraction methodologies, this phase-based approach was more time intensive, but did markedly increase abstraction reliability for unstructured data elements within multisite EMR documentation.

  13. Gigahertz frequency comb from a diode-pumped solid-state laser.

    PubMed

    Klenner, Alexander; Schilt, Stéphane; Südmeyer, Thomas; Keller, Ursula

    2014-12-15

    We present the first stabilization of the frequency comb offset from a diode-pumped gigahertz solid-state laser oscillator. No additional external amplification and/or compression of the output pulses is required. The laser is reliably modelocked using a SESAM and is based on a diode-pumped Yb:CALGO gain crystal. It generates 1.7-W average output power and pulse durations as short as 64 fs at a pulse repetition rate of 1 GHz. We generate an octave-spanning supercontinuum in a highly nonlinear fiber and use the standard f-to-2f carrier-envelope offset (CEO) frequency fCEO detection method. As a pump source, we use a reliable and cost-efficient commercial diode laser. Its multi-spatial-mode beam profile leads to a relatively broad frequency comb offset beat signal, which nevertheless can be phase-locked by feedback to its current. Using improved electronics, we reached a feedback-loop-bandwidth of up to 300 kHz. A combination of digital and analog electronics is used to achieve a tight phase-lock of fCEO to an external microwave reference with a low in-loop residual integrated phase-noise of 744 mrad in an integration bandwidth of [1 Hz, 5 MHz]. An analysis of the laser noise and response functions is presented which gives detailed insights into the CEO stabilization of this frequency comb.

  14. Validation of the 'Test of the Adherence to Inhalers' (TAI) for Asthma and COPD Patients.

    PubMed

    Plaza, Vicente; Fernández-Rodríguez, Concepción; Melero, Carlos; Cosío, Borja G; Entrenas, Luís Manuel; de Llano, Luis Pérez; Gutiérrez-Pereyra, Fernando; Tarragona, Eduard; Palomino, Rosa; López-Viña, Antolín

    2016-04-01

    To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were defined as adherents. Construct validity, internal validity, and criterion validity were evaluated. Self-reported adherence was compared with the Morisky-Green questionnaire. Factor analysis study demonstrated two factors, factor 1 was coincident with TAI patient domain (items 1 to 10) and factor 2 with TAI health-care professional domain (items 11 and 12). The Cronbach's alpha was 0.860 and the test-retest reliability 0.883. TAI scores correlated with electronic adherence (ρ=0.293, p=0.01). According to the best cut-off for 10 items (score 50, area under the ROC curve 0.7), 569 (62.5%) patients were classified as non-adherents. The non-adherence behavior pattern was: erratic 527 (57.9%), deliberate 375 (41.2%), and unwitting 242 (26.6%) patients. As compared to Morisky-Green test, TAI showed better psychometric properties. The TAI is a reliable and homogeneous questionnaire to identify easily non-adherence and to classify from a clinical perspective the barriers related to the use of inhalers in asthma and COPD.

  15. Power-Efficient, High-Current-Density, Long-Life Thermionic Cathode Developed for Microwave Amplifier Applications

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.

    2002-01-01

    A power-efficient, miniature, easily manufactured, reservoir-type barium-dispenser thermionic cathode has been developed that offers the significant advantages of simultaneous high electron-emission current density (>2 A/sq cm) and very long life (>100,000 hr of continuous operation) when compared with the commonly used impregnated-type barium-dispenser cathodes. Important applications of this cathode are a wide variety of microwave and millimeter-wave vacuum electronic devices, where high output power and reliability (long life) are essential. We also expect it to enable the practical development of higher purveyance electron guns for lower voltage and more reliable device operation. The low cathode heater power and reduced size and mass are expected to be particularly beneficial in traveling-wave-tube amplifiers (TWTA's) for space communications, where future NASA mission requirements include smaller onboard spacecraft systems, higher data transmission rates (high frequency and output power) and greater electrical efficiency.

  16. NASA-DoD Lower Process Temperature Lead-Free Solder Project Overview

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2014-01-01

    This project is a follow-on effort to the Joint Council on Aging AircraftJoint Group on Pollution Prevention (JCAAJG-PP) Pb-free Solder Project and NASA-DoD Lead-Free Electronics Project which were the first projects to test the reliability of Pb-free solder joints against the requirements of the aerospace and military community. This effort would continue to build on the results from the JCAAJG-PP Lead-Free Solder Project and NASA-DoD Lead-Free Electronics Project while focusing on a particular failure mechanism currently plaguing Pb-free assemblies, pad cratering.The NASA-DoD Lead-Free Electronics Project confirmed that pad cratering is one of the dominant failure modes that occur in various board level reliability tests, especially under dynamic loading. Pad Cratering is a latent defect that may occur during assembly, rework, and post assembly handling and testing.

  17. Electronics for Deep Space Cryogenic Applications

    NASA Technical Reports Server (NTRS)

    Patterson, R. L.; Hammond, A.; Dickman, J. E.; Gerber, S. S.; Elbuluk, M. E.; Overton, E.

    2002-01-01

    Deep space probes and planetary exploration missions require electrical power management and control systems that are capable of efficient and reliable operation in very cold temperature environments. Typically, in deep space probes, heating elements are used to keep the spacecraft electronics near room temperature. The utilization of power electronics designed for and operated at low temperature will contribute to increasing efficiency and improving reliability of space power systems. At NASA Glenn Research Center, commercial-off-the-shelf devices as well as developed components are being investigated for potential use at low temperatures. These devices include semiconductor switching devices, magnetics, and capacitors. Integrated circuits such as digital-to-analog and analog-to-digital converters, DC/DC converters, operational amplifiers, and oscillators are also being evaluated. In this paper, results will be presented for selected analog-to-digital converters, oscillators, DC/DC converters, and pulse width modulation (PWM) controllers.

  18. Stretchable biocompatible electronics by embedding electrical circuitry in biocompatible elastomers.

    PubMed

    Jahanshahi, Amir; Salvo, Pietro; Vanfleteren, Jan

    2012-01-01

    Stretchable and curvilinear electronics has been used recently for the fabrication of micro systems interacting with the human body. The applications range from different kinds of implantable sensors inside the body to conformable electrodes and artificial skins. One of the key parameters in biocompatible stretchable electronics is the fabrication of reliable electrical interconnects. Although very recent literature has reported on the reliability of stretchable interconnects by cyclic loading, work still needs to be done on the integration of electrical circuitry composed of rigid components and stretchable interconnects in a biological environment. In this work, the feasibility of a developed technology to fabricate simple electrical circuits with meander shaped stretchable interconnects is presented. Stretchable interconnects are 200 nm thin Au layer supported with polyimide (PI). A stretchable array of light emitting diodes (LEDs) is embedded in biocompatible elastomer using this technology platform and it features a 50% total elongation.

  19. A Review on VSC-HVDC Reliability Modeling and Evaluation Techniques

    NASA Astrophysics Data System (ADS)

    Shen, L.; Tang, Q.; Li, T.; Wang, Y.; Song, F.

    2017-05-01

    With the fast development of power electronics, voltage-source converter (VSC) HVDC technology presents cost-effective ways for bulk power transmission. An increasing number of VSC-HVDC projects has been installed worldwide. Their reliability affects the profitability of the system and therefore has a major impact on the potential investors. In this paper, an overview of the recent advances in the area of reliability evaluation for VSC-HVDC systems is provided. Taken into account the latest multi-level converter topology, the VSC-HVDC system is categorized into several sub-systems and the reliability data for the key components is discussed based on sources with academic and industrial backgrounds. The development of reliability evaluation methodologies is reviewed and the issues surrounding the different computation approaches are briefly analysed. A general VSC-HVDC reliability evaluation procedure is illustrated in this paper.

  20. Carbon nanomaterials for electronics, optoelectronics, photovoltaics, and sensing.

    PubMed

    Jariwala, Deep; Sangwan, Vinod K; Lauhon, Lincoln J; Marks, Tobin J; Hersam, Mark C

    2013-04-07

    In the last three decades, zero-dimensional, one-dimensional, and two-dimensional carbon nanomaterials (i.e., fullerenes, carbon nanotubes, and graphene, respectively) have attracted significant attention from the scientific community due to their unique electronic, optical, thermal, mechanical, and chemical properties. While early work showed that these properties could enable high performance in selected applications, issues surrounding structural inhomogeneity and imprecise assembly have impeded robust and reliable implementation of carbon nanomaterials in widespread technologies. However, with recent advances in synthesis, sorting, and assembly techniques, carbon nanomaterials are experiencing renewed interest as the basis of numerous scalable technologies. Here, we present an extensive review of carbon nanomaterials in electronic, optoelectronic, photovoltaic, and sensing devices with a particular focus on the latest examples based on the highest purity samples. Specific attention is devoted to each class of carbon nanomaterial, thereby allowing comparative analysis of the suitability of fullerenes, carbon nanotubes, and graphene for each application area. In this manner, this article will provide guidance to future application developers and also articulate the remaining research challenges confronting this field.

  1. Bright-field electron tomography of individual inorganic fullerene-like structures.

    PubMed

    Bar Sadan, Maya; Wolf, Sharon G; Houben, Lothar

    2010-03-01

    Nanotubes and fullerene-like nanoparticles of various inorganic layered compounds have been studied extensively in recent years. Their characterisation on the atomic scale has proven essential for progress in synthesis as well as for the theoretical modelling of their physical properties. We show that with electron tomography it is possible to achieve a reliable reconstruction of the 3D structure of nested WS(2) or MoS(2) fullerene-like and nanotube structures with sub-nanometre resolution using electron microscopes that are not aberration-corrected. Model-based simulations were used to identify imaging parameters, under which structural features such as the shell structure can be retained in the tomogram reconstructed from bright-field micrographs. The isolation of a particle out of an agglomerate for the analysis of a single structure and its interconnection with other particles is facilitated through the tomograms. The internal structure of the layers within the particle alongside the shape and content of its internal void are reconstructed. The tomographic reconstruction yields insights regarding the growth process as well as structural defects, such as non-continuous layers, which relate to the lubrication properties.

  2. Thermally Stabilized Transmit/Receive Modules

    NASA Technical Reports Server (NTRS)

    Hoffman, James; DelCastillo, Linda; Miller, Jennifer; Birur, Gaj

    2011-01-01

    RF-hybrid technologies enable smaller packaging and mass reduction in radar instruments, especially for subsystems with dense electronics, such as electronically steered arrays. We are designing thermally stabilized RF-hybrid T/R modules using new materials for improved thermal performance of electronics. We are combining advanced substrate and housing materials with a thermal reservoir material, and develop new packaging techniques to significantly improve thermal-cycling reliability and performance stability over temperature.

  3. Electronics for Low Temperature Space Exploration Missions

    NASA Technical Reports Server (NTRS)

    Patterson, Richard L.; Hammoud, Ahmad; Elbuluk, Malik

    2007-01-01

    Exploration missions to outer planets and deep space require spacecraft, probes, and on-board data and communication systems to operate reliably and efficiently under severe harsh conditions. On-board electronics, in particular those in direct exposures to the space environment without any shielding or protection, will encounter extreme low temperature and thermal cycling in their service cycle in most of NASA s upcoming exploration missions. For example, Venus atmosphere, Jupiter atmosphere, Moon surface, Pluto orbiter, Mars, comets, Titan, Europa, and James Webb Space Telescope all involve low-temperature surroundings. Therefore, electronics for space exploration missions need to be designed for operation under such environmental conditions. There are ongoing efforts at the NASA Glenn Research Center (GRC) to establish a database on the operation and reliability of electronic devices and circuits under extreme temperature operation for space applications. This work is being performed under the Extreme Temperature Electronics Program with collaboration and support of the NASA Electronic Parts and Packaging (NEPP) Program. The results of these investigations will be used to establish safe operating areas and to identify degradation and failure modes, and the information will be disseminated to mission planners and system designers for use as tools for proper part selection and in risk mitigation. An overview of this program along with experimental data will be presented.

  4. The Use of Probabilistic Methods to Evaluate the Systems Impact of Component Design Improvements on Large Turbofan Engines

    NASA Technical Reports Server (NTRS)

    Packard, Michael H.

    2002-01-01

    Probabilistic Structural Analysis (PSA) is now commonly used for predicting the distribution of time/cycles to failure of turbine blades and other engine components. These distributions are typically based on fatigue/fracture and creep failure modes of these components. Additionally, reliability analysis is used for taking test data related to particular failure modes and calculating failure rate distributions of electronic and electromechanical components. How can these individual failure time distributions of structural, electronic and electromechanical component failure modes be effectively combined into a top level model for overall system evaluation of component upgrades, changes in maintenance intervals, or line replaceable unit (LRU) redesign? This paper shows an example of how various probabilistic failure predictions for turbine engine components can be evaluated and combined to show their effect on overall engine performance. A generic model of a turbofan engine was modeled using various Probabilistic Risk Assessment (PRA) tools (Quantitative Risk Assessment Software (QRAS) etc.). Hypothetical PSA results for a number of structural components along with mitigation factors that would restrict the failure mode from propagating to a Loss of Mission (LOM) failure were used in the models. The output of this program includes an overall failure distribution for LOM of the system. The rank and contribution to the overall Mission Success (MS) is also given for each failure mode and each subsystem. This application methodology demonstrates the effectiveness of PRA for assessing the performance of large turbine engines. Additionally, the effects of system changes and upgrades, the application of different maintenance intervals, inclusion of new sensor detection of faults and other upgrades were evaluated in determining overall turbine engine reliability.

  5. Electron Spin Resonance (ESR) for the study of Reactive Oxygen Species (ROS) on the isolated frog skin (Pelophylax bergeri): A non-invasive method for environmental monitoring.

    PubMed

    D'Errico, Gerardino; Vitiello, Giuseppe; De Tommaso, Gaetano; Abdel-Gawad, Fagr Kh; Brundo, Maria Violetta; Ferrante, Margherita; De Maio, Anna; Trocchia, Samantha; Bianchi, Anna Rita; Ciarcia, Gaetano; Guerriero, Giulia

    2018-04-11

    Reactive oxygen species (ROS) in biological tissues of elected biosentinels represent an optimal biomarker for eco-monitoring of polluted areas. Electron spin resonance (ESR) is the most definitive method for detecting, quantifying and possibly identifying radicals in complex systems. A non-invasive method for monitoring polluted areas by the quantitative determination of ROS in frog skin biopsy is presented. We assessed by ESR spectroscopy the ROS level in adult male of Pelophylax bergeri, specie not a risk of extinction, collected from the polluted Sarno River (SA, Italy) basin. The spin-trap ESR method was validated by immunohistochemical analysis of the well-assessed pollution biomarkers cytochrome P450 aromatase 1A (CYP1A) and glutathione S-transferase (GST), and by determining the poly(ADPribose) polymerase (PARP) and GST enzymatic activity. ROS concentration in skin samples from frogs collected in the polluted area is significantly higher than that determined for the unpolluted reference area. Immunohistochemical analysis of CYP1A and GST supported the reliability of our approach, even in the absence of evident morphological and ultrastructural differences. PARP activity assay, connected to possible oxidative DNA damage, and the detoxification index by GST enzymatic assay give statistically significant evidence that higher levels of ROS are associated to alterations of the different biomarkers. ROS concentration, measured by ESR on isolated frog skin, through the presented non-lethal method, is a reliable biomarker for toxicity screening and represents a useful basic datum for future modelling studies on environmental monitoring and biodiversity loss prevention. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. NASA TEERM Hexavalent Chrome Alternatives Projects

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.; Rothgeb, Matthew

    2011-01-01

    The overall objective of the Hex Chrome Free Coatings for Electronics project is to evaluate and test pretreatment coating systems not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders. The technical stakeholders have agreed that this protocol will focus specifically on Class 3 coatings. Original Equipment Manufacturers (OEMs), depots, and support contractors have to be prepared to deal with an electronics supply chain that increasingly provides parts with lead-free finishes, some labeled no differently and intermingled with their SnPb counterparts. Allowance of lead-free components presents one of the greatest risks to the reliability of military and aerospace electronics. The introduction of components with lead-free terminations, termination finishes, or circuit boards presents a host of concerns to customers, suppliers, and maintainers of aerospace and military electronic systems such as: 1. Electrical shorting due to tin whiskers 2. Incompatibility of lead-free processes and parameters (including higher melting points of lead-free alloys) with other materials in the system 3. Unknown material properties and incompatibilities that could reduce solder joint reliability

  7. Evaluation of Reliability Coefficients for Two-Level Models via Latent Variable Analysis

    ERIC Educational Resources Information Center

    Raykov, Tenko; Penev, Spiridon

    2010-01-01

    A latent variable analysis procedure for evaluation of reliability coefficients for 2-level models is outlined. The method provides point and interval estimates of group means' reliability, overall reliability of means, and conditional reliability. In addition, the approach can be used to test simple hypotheses about these parameters. The…

  8. Synthesis of the natural product building block 5-(3-bromophenyl)-4-hydroxy-5-methylhexan-2-one and its chiral characterization by using chiroptical spectroscopy.

    PubMed

    De Gussem, Ewoud; Cornelus, Jelle; Pieters, Sam; Van den Bossche, Dries; Van der Eycken, Johan; Herrebout, Wouter; Bultinck, Patrick

    2013-10-07

    The absolute configuration of 5-(3-bromophenyl)-4-hydroxy-5-methylhexan-2-one, an intermediate in the synthesis of various natural products, is assigned by using vibrational circular dichroism (VCD), electronic circular dichroism (ECD), and optical rotatory dispersion (ORD). Experimental spectra were compared to density functional theory (DFT) calculations of the molecule with known configuration. These three techniques independently confirm that the absolute configuration is (S)-5-(3-bromophenyl)-4-hydroxy-5-methylhexan-2-one, thus enabling us to assign the absolute configuration with high reliability. The reliability of the VCD analysis was assessed quantitatively by using the CompareVOA program. We found that, in cases in which the agreement between theory and experiment was very good, a value of 10 cm(-1) for the triangular weighting function gave a more-realistic discriminative power between enantiomers than the default value of 20 cm(-1). Copyright © 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Analysis of simplified heat transfer models for thermal property determination of nano-film by TDTR method

    NASA Astrophysics Data System (ADS)

    Wang, Xinwei; Chen, Zhe; Sun, Fangyuan; Zhang, Hang; Jiang, Yuyan; Tang, Dawei

    2018-03-01

    Heat transfer in nanostructures is of critical importance for a wide range of applications such as functional materials and thermal management of electronics. Time-domain thermoreflectance (TDTR) has been proved to be a reliable measurement technique for the thermal property determinations of nanoscale structures. However, it is difficult to determine more than three thermal properties at the same time. Heat transfer model simplifications can reduce the fitting variables and provide an alternative way for thermal property determination. In this paper, two simplified models are investigated and analyzed by the transform matrix method and simulations. TDTR measurements are performed on Al-SiO2-Si samples with different SiO2 thickness. Both theoretical and experimental results show that the simplified tri-layer model (STM) is reliable and suitable for thin film samples with a wide range of thickness. Furthermore, the STM can also extract the intrinsic thermal conductivity and interfacial thermal resistance from serial samples with different thickness.

  10. A two-in-one process for reliable graphene transistors processed with photo-lithography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahlberg, P.; Hinnemo, M.; Song, M.

    2015-11-16

    Research on graphene field-effect transistors (GFETs) has mainly relied on devices fabricated using electron-beam lithography for pattern generation, a method that has known problems with polymer contaminants. GFETs fabricated via photo-lithography suffer even worse from other chemical contaminations, which may lead to strong unintentional doping of the graphene. In this letter, we report on a scalable fabrication process for reliable GFETs based on ordinary photo-lithography by eliminating the aforementioned issues. The key to making this GFET processing compatible with silicon technology lies in a two-in-one process where a gate dielectric is deposited by means of atomic layer deposition. During thismore » deposition step, contaminants, likely unintentionally introduced during the graphene transfer and patterning, are effectively removed. The resulting GFETs exhibit current-voltage characteristics representative to that of intrinsic non-doped graphene. Fundamental aspects pertaining to the surface engineering employed in this work are investigated in the light of chemical analysis in combination with electrical characterization.« less

  11. A single-loop optimization method for reliability analysis with second order uncertainty

    NASA Astrophysics Data System (ADS)

    Xie, Shaojun; Pan, Baisong; Du, Xiaoping

    2015-08-01

    Reliability analysis may involve random variables and interval variables. In addition, some of the random variables may have interval distribution parameters owing to limited information. This kind of uncertainty is called second order uncertainty. This article develops an efficient reliability method for problems involving the three aforementioned types of uncertain input variables. The analysis produces the maximum and minimum reliability and is computationally demanding because two loops are needed: a reliability analysis loop with respect to random variables and an interval analysis loop for extreme responses with respect to interval variables. The first order reliability method and nonlinear optimization are used for the two loops, respectively. For computational efficiency, the two loops are combined into a single loop by treating the Karush-Kuhn-Tucker (KKT) optimal conditions of the interval analysis as constraints. Three examples are presented to demonstrate the proposed method.

  12. Evaluation of 10V Chip Polymer Tantalum Capacitors for Space Applications

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2016-01-01

    Due to low ESR and safe failure mode, new technology chip polymer tantalum capacitors (CPTC) have gained popularity in the electronics design community, first in commercial applications, and now in hi-rel and space systems. The major drawbacks of these parts are high leakage currents, degradation under environmental stresses, and a relatively narrow temperature range of operating and storage conditions. Several studies have shown that a certain amount of moisture in polymer cathodes is necessary for a normal operation of the parts. This might limit applications of CPTCs in space systems and requires analysis of long-term exposure to deep vacuum conditions on their performance and reliability. High leakage currents and limited maximum operational temperature complicate accelerated testing that is necessary to assess long-term reliability and require new screening and qualification procedures for quality assurance. A better understanding of behavior of CPTCs as compared to traditional, MnO2, capacitors is necessary to develop adequate approaches for QA system for space applications. A specific of CPTCs is that different materials and processes might be used for low-voltage (10 V and less) and high-voltage (above 10 V) capacitors, so performance and degradation processes in these groups require separate analysis. In this work, that is a part of the NASA Electronic Parts and Packaging (NEPP) program, degradation of AC and DC characteristics under environmental stresses at different temperatures and voltages have been studied in nine lots of commercial and automotive grade capacitors rated to 10 V. Results of analysis of leakage currents, high temperature storage (HTS) up to 5000 hrs in vacuum and air at different temperatures, and Highly Accelerated Life Testing (HALT) in the range from 85 C to 145 C are presented. Temperature and voltage acceleration factors were calculated based on approximation of distributions of degradation rates with a general log-linear Weibull model. Mechanisms of degradation and failures, and requirements for screening and qualification testing are discussed.

  13. Reliability Growth of Tactical Coolers at CMC Electronics Cincinnati: 1/5-Watt Cooler Test Report

    NASA Astrophysics Data System (ADS)

    Kuo, D. T.; Lody, T. D.

    2004-06-01

    CMC Electronics Cincinnati (CMC) is conducting a reliability growth program to extend the life of tactical Stirling-cycle cryocoolers. The continuous product improvement processes consist of testing production coolers to failure, determining the root cause, incorporating improvements and verification. The most recent life data for the 1/5-Watt Cooler (Model B512B) is presented with a discussion of leading root causes and potential improvements. The mean time to failure (MTTF) life of the coolers was found to be 22,552 hours with the root cause of failure attributed to the accumulation of methane and carbon dioxide in the cooler and the wear of the piston.

  14. Chapter 15: Reliability of Wind Turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Shuangwen; O'Connor, Ryan

    The global wind industry has witnessed exciting developments in recent years. The future will be even brighter with further reductions in capital and operation and maintenance costs, which can be accomplished with improved turbine reliability, especially when turbines are installed offshore. One opportunity for the industry to improve wind turbine reliability is through the exploration of reliability engineering life data analysis based on readily available data or maintenance records collected at typical wind plants. If adopted and conducted appropriately, these analyses can quickly save operation and maintenance costs in a potentially impactful manner. This chapter discusses wind turbine reliability bymore » highlighting the methodology of reliability engineering life data analysis. It first briefly discusses fundamentals for wind turbine reliability and the current industry status. Then, the reliability engineering method for life analysis, including data collection, model development, and forecasting, is presented in detail and illustrated through two case studies. The chapter concludes with some remarks on potential opportunities to improve wind turbine reliability. An owner and operator's perspective is taken and mechanical components are used to exemplify the potential benefits of reliability engineering analysis to improve wind turbine reliability and availability.« less

  15. A multifrequency virtual spectrometer for complex bio-organic systems: vibronic and environmental effects on the UV/Vis spectrum of chlorophyll a.

    PubMed

    Barone, Vincenzo; Biczysko, Malgorzata; Borkowska-Panek, Monika; Bloino, Julien

    2014-10-20

    The subtle interplay of several different effects means that the interpretation and analysis of experimental spectra in terms of structural and dynamic characteristics is a challenging task. In this context, theoretical studies can be helpful, and as such, computational spectroscopy is rapidly evolving from a highly specialized research field toward a versatile and widespread tool. However, in the case of electronic spectra (e.g. UV/Vis, circular dichroism, photoelectron, and X-ray spectra), the most commonly used methods still rely on the computation of vertical excitation energies, which are further convoluted to simulate line shapes. Such treatment completely neglects the influence of nuclear motions, despite the well-recognized notion that a proper account of vibronic effects is often mandatory to correctly interpret experimental findings. Development and validation of improved models rooted into density functional theory (DFT) and its time-dependent extension (TD-DFT) is of course instrumental for the optimal balance between reliability and favorable scaling with the number of electrons. However, the implementation of easy-to-use and effective procedures to simulate vibrationally resolved electronic spectra, and their availability to a wide community of users, is at least equally important for reliable simulations of spectral line shapes for compounds of biological and technological interest. Here, such an approach has been applied to the study of the UV/Vis spectra of chlorophyll a. The results show that properly tailored approaches are feasible for state-of-the-art computational spectroscopy studies, and allow, with affordable computational resources, vibrational and environmental effects on the spectral line shapes to be taken into account for large systems. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. A Most Probable Point-Based Method for Reliability Analysis, Sensitivity Analysis and Design Optimization

    NASA Technical Reports Server (NTRS)

    Hou, Gene J.-W; Newman, Perry A. (Technical Monitor)

    2004-01-01

    A major step in a most probable point (MPP)-based method for reliability analysis is to determine the MPP. This is usually accomplished by using an optimization search algorithm. The minimum distance associated with the MPP provides a measurement of safety probability, which can be obtained by approximate probability integration methods such as FORM or SORM. The reliability sensitivity equations are derived first in this paper, based on the derivatives of the optimal solution. Examples are provided later to demonstrate the use of these derivatives for better reliability analysis and reliability-based design optimization (RBDO).

  17. Commercial Off-The-Shelf (COTS) Electronics Reliability for Space Applications

    NASA Technical Reports Server (NTRS)

    Pellish, Jonathan

    2018-01-01

    This presentation describes the accelerating use of Commercial off the Shelf (COTS) parts in space applications. Component reliability and threats in the context of the mission, environment, application, and lifetime. Provides overview of traditional approaches applied to COTS parts in flight applications, and shows challenges and potential paths forward for COTS systems in flight applications it's all about data!

  18. High Reliability of 0.1 μm InGaAs/InAlAs/InP High Electron Mobility Transistors Microwave Monolithic Integrated Circuit on 3-inch InP Substrates

    NASA Astrophysics Data System (ADS)

    Chou, Yeong-Chang; Leung, Denise; Lai, Richard; Grundbacher, Ron; Scarpulla, John; Barsky, Mike; Nishimoto, Matt; Eng, David; Liu, Po-Hsin; Oki, Aaron; Streit, Dwight

    2002-02-01

    The high-reliability performance of K-band microwave monolithic integrated circuit (MMIC) amplifiers fabricated with 0.1 μm gate length InGaAs/InAlAs/InP high electron mobility transistors (HEMTs) on 3-inch wafers using a high volume production process technology is reported. Operating at an accelerated life test condition of Vds=1.5 V and Ids=150 mA/mm, two-stage balanced amplifiers were lifetested at two-temperatures (T1=230°C, and T2=250°C) in nitrogen ambient. The activation energy (Ea) is as high as 1.5 eV, achieving a projected median-time-to-failure (MTTF) >1× 106 h at a 125°C of junction temperature. MTTF was determined by 2-temperature constant current stress using |Δ S21|>1.0 dB as the failure criteria. This is the first report of high reliability 0.1 μm InGaAs/InAlAs/InP HEMT MMICs based on small-signal microwave characteristics. This result demonstrates a reliable InGaAs/InAlAs/InP HEMT production technology.

  19. One-year test-retest reliability of intrinsic connectivity network fMRI in older adults

    PubMed Central

    Guo, Cong C.; Kurth, Florian; Zhou, Juan; Mayer, Emeran A.; Eickhoff, Simon B; Kramer, Joel H.; Seeley, William W.

    2014-01-01

    “Resting-state” or task-free fMRI can assess intrinsic connectivity network (ICN) integrity in health and disease, suggesting a potential for use of these methods as disease-monitoring biomarkers. Numerous analytical options are available, including model-driven ROI-based correlation analysis and model-free, independent component analysis (ICA). High test-retest reliability will be a necessary feature of a successful ICN biomarker, yet available reliability data remains limited. Here, we examined ICN fMRI test-retest reliability in 24 healthy older subjects scanned roughly one year apart. We focused on the salience network, a disease-relevant ICN not previously subjected to reliability analysis. Most ICN analytical methods proved reliable (intraclass coefficients > 0.4) and could be further improved by wavelet analysis. Seed-based ROI correlation analysis showed high map-wise reliability, whereas graph theoretical measures and temporal concatenation group ICA produced the most reliable individual unit-wise outcomes. Including global signal regression in ROI-based correlation analyses reduced reliability. Our study provides a direct comparison between the most commonly used ICN fMRI methods and potential guidelines for measuring intrinsic connectivity in aging control and patient populations over time. PMID:22446491

  20. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging. Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVoto, Douglas

    2016-04-01

    Current generation automotive power electronics packages utilize silicon devices and lead-free solder alloys. To meet stringent technical targets for 2020 and beyond (for cost, power density, specific power, efficiency and reliability), wide-bandgap devices are being considered since they offer advantages such as operation at higher frequencies, voltages, and temperatures. Traditional power electronics packages must be redesigned to utilize the full potential of wide-bandgap devices, and the die- and substrate-attach layers are key areas where new material development and validation is required. Present solder alloys do not meet the performance requirements for these new package designs while also meeting cost andmore » hazardous substance restrictions. Sintered silver (Ag) promises to meet the needs for die- and substrate-attach interfaces but synthesis optimization and reliability evaluation must be completed. Sintered Ag material was proposed as an alternative solution in power electronics packages almost 20 years back. However, synthesis pressure requirements up 40 MPa caused a higher complexity in the production process and more stringent flatness specifications for the substrates. Recently, several manufacturers have developed sintered Ag materials that require lower (3-5 MPa) or even no bonding pressures. Degradation mechanisms for these sintered Ag materials are not well known and need to be addressed. We are addressing these aspects to some extent in this project. We are developing generalized (i.e., independent of geometry) stress intensity factor versus cycles-to-failure relations for sintered Ag. Because sintered Ag is a relatively new material for automotive power electronics, the industry currently does not have a good understanding of recommended synthesis parameters or expected reliability under prescribed conditions. It is an important deliverable of this project to transfer findings to industry to eliminate barriers to using sintered Ag as a viable and commercialized die- and substrate-attach material. Only a few manufacturers produce sintered Ag pastes and may consider some processing conditions as proprietary. It is the goal of this project to openly explore and define best practices in order to impact the maximum number of power electronics module manufacturers and suppliers.« less

  1. PCM/TD-DFT analysis of 1-bromo-2,3-dichlorobenzene--a combined study of experimental (FT-IR and FT-Raman) and theoretical calculations.

    PubMed

    Arivazhagan, M; Muniappan, P; Meenakshi, R; Rajavel, G

    2013-03-15

    This study represents an integral approach towards understanding the electronic and structural aspects of 1-bromo-2,3-dichlorobenzene (BDCB). The experimental spectral bands were structurally assigned with the theoretical calculation, and the thermodynamic properties of the studied compound were obtained from the theoretically calculated frequencies. The relationship between the structure and absorption spectrum and effects of solvents have been discussed. It turns that the hybrid PBE1PBE functional with 6-311+G(d,p) basis provide reliable λ(max) when solvent effects are included in the model. The NBO analysis reveals that the studied compound presents a structural characteristic of electron-transfer within the compound. The frontier molecular orbitals (HOMO-LUMO) are responsible for the electron polarization and electron-transfer properties. The reactivity sites are identified by mapping the electron density into electrostatic potential surface (MESP). Besides, (13)C and (1)H have been calculated using the gauge-invariant atomic orbital (GIAO) method. The thermodynamic properties at different temperatures were calculated, revealing the correlations between standard heat capacity, standard entropy, standard enthalpy changes and temperatures. Furthermore, the studied compound can be used as a good nonlinear optical material due to the higher value of first hyper polarizability (5.7 times greater than that of urea (0.37289×10(-30) esu)). Finally, it is worth to mentioning that solvent induces a considerable red shift of the absorption maximum going from the gas phase, and a slight blue shift of the transition S(0)→S(1) going from less polar to more polar solvents. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Reliable screening of various foodstuffs with respect to their irradiation status: A comparative study of different analytical techniques

    NASA Astrophysics Data System (ADS)

    Ahn, Jae-Jun; Akram, Kashif; Kwak, Ji-Young; Jeong, Mi-Seon; Kwon, Joong-Ho

    2013-10-01

    Cost-effective and time-efficient analytical techniques are required to screen large food lots in accordance to their irradiation status. Gamma-irradiated (0-10 kGy) cinnamon, red pepper, black pepper, and fresh paprika were investigated using photostimulated luminescence (PSL), direct epifluorescent filter technique/the aerobic plate count (DEFT/APC), and electronic-nose (e-nose) analyses. The screening results were also confirmed with thermoluminescence analysis. PSL analysis discriminated between irradiated (positive, >5000 PCs) and non-irradiated (negative, <700 PCs) cinnamon and red peppers. Black pepper had intermediate results (700-5000 PCs), while paprika had low sensitivity (negative results) upon irradiation. The DEFT/APC technique also showed clear screening results through the changes in microbial profiles, where the best results were found in paprika, followed by red pepper and cinnamon. E-nose analysis showed a dose-dependent discrimination in volatile profiles upon irradiation through principal component analysis. These methods can be used considering their potential applications for the screening analysis of irradiated foods.

  3. NASA Applications and Lessons Learned in Reliability Engineering

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.; Fuller, Raymond P.

    2011-01-01

    Since the Shuttle Challenger accident in 1986, communities across NASA have been developing and extensively using quantitative reliability and risk assessment methods in their decision making process. This paper discusses several reliability engineering applications that NASA has used over the year to support the design, development, and operation of critical space flight hardware. Specifically, the paper discusses several reliability engineering applications used by NASA in areas such as risk management, inspection policies, components upgrades, reliability growth, integrated failure analysis, and physics based probabilistic engineering analysis. In each of these areas, the paper provides a brief discussion of a case study to demonstrate the value added and the criticality of reliability engineering in supporting NASA project and program decisions to fly safely. Examples of these case studies discussed are reliability based life limit extension of Shuttle Space Main Engine (SSME) hardware, Reliability based inspection policies for Auxiliary Power Unit (APU) turbine disc, probabilistic structural engineering analysis for reliability prediction of the SSME alternate turbo-pump development, impact of ET foam reliability on the Space Shuttle System risk, and reliability based Space Shuttle upgrade for safety. Special attention is given in this paper to the physics based probabilistic engineering analysis applications and their critical role in evaluating the reliability of NASA development hardware including their potential use in a research and technology development environment.

  4. Bearing Procurement Analysis Method by Total Cost of Ownership Analysis and Reliability Prediction

    NASA Astrophysics Data System (ADS)

    Trusaji, Wildan; Akbar, Muhammad; Sukoyo; Irianto, Dradjad

    2018-03-01

    In making bearing procurement analysis, price and its reliability must be considered as decision criteria, since price determines the direct cost as acquisition cost and reliability of bearing determine the indirect cost such as maintenance cost. Despite the indirect cost is hard to identify and measured, it has high contribution to overall cost that will be incurred. So, the indirect cost of reliability must be considered when making bearing procurement analysis. This paper tries to explain bearing evaluation method with the total cost of ownership analysis to consider price and maintenance cost as decision criteria. Furthermore, since there is a lack of failure data when bearing evaluation phase is conducted, reliability prediction method is used to predict bearing reliability from its dynamic load rating parameter. With this method, bearing with a higher price but has higher reliability is preferable for long-term planning. But for short-term planning the cheaper one but has lower reliability is preferable. This contextuality can give rise to conflict between stakeholders. Thus, the planning horizon needs to be agreed by all stakeholder before making a procurement decision.

  5. X-ray absorption spectroscopic studies of mononuclear non-heme iron enzymes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westre, Tami E.

    Fe-K-edge X-ray absorption spectroscopy (XAS) has been used to investigate the electronic and geometric structure of the iron active site in non-heme iron enzymes. A new theoretical extended X-ray absorption fine structure (EXAFS) analysis approach, called GNXAS, has been tested on data for iron model complexes to evaluate the utility and reliability of this new technique, especially with respect to the effects of multiple-scattering. In addition, a detailed analysis of the 1s→3d pre-edge feature has been developed as a tool for investigating the oxidation state, spin state, and geometry of iron sites. Edge and EXAFS analyses have then been appliedmore » to the study of non-heme iron enzyme active sites.« less

  6. A versatile localization system for microscopic multiparametric analysis of cells.

    PubMed

    Thaw, H H; Rundquist, I; Johansson, U; Svensson, I; Collins, V P

    1983-03-01

    A new, simple and relatively inexpensive electronic digital position readout (DPRO) system which can be applied to the rapid localization and recovery of microscopic material is described. It is based upon a commercially available digital position readout system which is routinely utilized by industry for small machine tools and measuring equipment. This has been mounted onto the stage of various microscopic instrumentation to provide X and Y coordinates relative to an arbitrary reference point. The integration of small computers interfaced to scanning interferometric, microdensitometric and fluorescence microscopes were used to demonstrate the reliability, versatility and ease of application of this system to problems of multiparametric measurements and analysis of cultured cells. The system may be expanded and applied to clinical material to obtain automatized, multiparametric measurements of cells in haematology and clinical cytology.

  7. Assistive Potencies: Reconfiguring the Scholarly Edition in an Electronic Setting

    ERIC Educational Resources Information Center

    Lyman, Eugene William

    2009-01-01

    This dissertation makes the claim that electronic scholarly editions have the potential to produce more reliable scholarly texts than their print-based antecedents. It consists of an introduction, four chapters, and a brief conclusion. It originated in my work creating the Elwood Viewer, a sophisticated software browser written to display TEI…

  8. 77 FR 16158 - Current Good Manufacturing Practice in Manufacturing, Processing, Packing, or Holding of Drugs...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ... ``cut'' from a sheet or roll of labels--is used. Persistent problems with drug product mislabeling and... believe that development and use of advanced code scanning equipment has made many current electronic... and other advanced scanning techniques have made current electronic systems reliable to the 100...

  9. Usage Data for Electronic Resources: A Comparison between Locally Collected and Vendor-Provided Statistics.

    ERIC Educational Resources Information Center

    Duy, Joanna; Vaughan, Liwen

    2003-01-01

    Vendor-provided electronic resource usage statistics are not currently standardized across vendors. This study investigates the feasibility of using locally collected data to check the reliability of vendor-provided data. Vendor-provided data were compared with local data collected from North Carolina State University (NCSU) Libraries' Web…

  10. Ultracompliant Heterogeneous Copper-Tin Nanowire Arrays Making a Supersolder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narumanchi, Sreekant V; Feng, Xuhui; Major, Joshua

    Due to the substantial increase in power density, thermal interface resistance that can constitute more than 50% of the total thermal resistance has generally become a bottleneck for thermal management in electronics. However, conventional thermal interface materials (TIMs) such as solder, epoxy, gel, and grease cannot fulfill the requirements of electronics for high-power and long-term operation. Here, we demonstrate a high-performance TIM consisting of a heterogeneous copper-tin nanowire array, which we term 'supersolder' to emulate the role of conventional solders in bonding various surfaces. The supersolder is ultracompliant with a shear modulus 2-3 orders of magnitude lower than traditional soldersmore » and can reduce the thermal resistance by two times as compared with the state-of-the-art TIMs. This supersolder also exhibits excellent long-term reliability with >1200 thermal cycles over a wide temperature range. By resolving this critical thermal bottleneck, the supersolder enables electronic systems, ranging from microelectronics and portable electronics to massive data centers, to operate at lower temperatures with higher power density and reliability.« less

  11. A vacuum-sealed compact x-ray tube based on focused carbon nanotube field-emission electrons

    NASA Astrophysics Data System (ADS)

    Jeong, Jin-Woo; Kim, Jae-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho

    2013-03-01

    We report on a fully vacuum-sealed compact x-ray tube based on focused carbon nanotube (CNT) field-emission electrons for various radiography applications. The specially designed two-step brazing process enabled us to accomplish a good vacuum level for the stable and reliable operation of the x-ray tube without any active vacuum pump. Also, the integrated focusing electrodes in the field-emission electron gun focused electron beams from the CNT emitters onto the anode target effectively, giving a small focal spot of around 0.3 mm with a large current of above 50 mA. The active-current control through the cathode electrode of the x-ray tube led a fast digital modulation of x-ray dose with a low voltage of below 5 V. The fabricated compact x-ray tube showed a stable and reliable operation, indicating good maintenance of a vacuum level of below 5 × 10-6 Torr and the possibility of field-emission x-ray tubes in a stand-alone device without an active pumping system.

  12. Probabilistic Finite Element Analysis & Design Optimization for Structural Designs

    NASA Astrophysics Data System (ADS)

    Deivanayagam, Arumugam

    This study focuses on implementing probabilistic nature of material properties (Kevlar® 49) to the existing deterministic finite element analysis (FEA) of fabric based engine containment system through Monte Carlo simulations (MCS) and implementation of probabilistic analysis in engineering designs through Reliability Based Design Optimization (RBDO). First, the emphasis is on experimental data analysis focusing on probabilistic distribution models which characterize the randomness associated with the experimental data. The material properties of Kevlar® 49 are modeled using experimental data analysis and implemented along with an existing spiral modeling scheme (SMS) and user defined constitutive model (UMAT) for fabric based engine containment simulations in LS-DYNA. MCS of the model are performed to observe the failure pattern and exit velocities of the models. Then the solutions are compared with NASA experimental tests and deterministic results. MCS with probabilistic material data give a good prospective on results rather than a single deterministic simulation results. The next part of research is to implement the probabilistic material properties in engineering designs. The main aim of structural design is to obtain optimal solutions. In any case, in a deterministic optimization problem even though the structures are cost effective, it becomes highly unreliable if the uncertainty that may be associated with the system (material properties, loading etc.) is not represented or considered in the solution process. Reliable and optimal solution can be obtained by performing reliability optimization along with the deterministic optimization, which is RBDO. In RBDO problem formulation, in addition to structural performance constraints, reliability constraints are also considered. This part of research starts with introduction to reliability analysis such as first order reliability analysis, second order reliability analysis followed by simulation technique that are performed to obtain probability of failure and reliability of structures. Next, decoupled RBDO procedure is proposed with a new reliability analysis formulation with sensitivity analysis, which is performed to remove the highly reliable constraints in the RBDO, thereby reducing the computational time and function evaluations. Followed by implementation of the reliability analysis concepts and RBDO in finite element 2D truss problems and a planar beam problem are presented and discussed.

  13. NASA and COTS Electronics: Past Approach and Successes - Future Considerations

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.

    2018-01-01

    NASA has a long history of using commercial grade electronics in space. In this talk, a brief history of NASAâ's trends and approaches to commercial grade electronics focusing on processing and memory systems will be presented. This will include providing summary information on the space hazards to electronics as well as NASA mission trade space. We will also discuss developing recommendations for risk management approaches to Electrical, Electronic and Electromechanical (EEE) parts and reliability in space. The final portion of the talk will discuss emerging aerospace trends and the future for Commercial Off The Shelf (COTS) usage.

  14. Carbon Nanotube Electron Gun

    NASA Technical Reports Server (NTRS)

    Ribaya, Bryan P. (Inventor); Nguyen, Cattien V. (Inventor)

    2013-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  15. Carbon nanotube electron gun

    NASA Technical Reports Server (NTRS)

    Nguyen, Cattien V. (Inventor); Ribaya, Bryan P. (Inventor)

    2010-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  16. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 3: HARP Graphics Oriented (GO) input user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.

  17. Electron/proton spectrometer certification documentation analyses

    NASA Technical Reports Server (NTRS)

    Gleeson, P.

    1972-01-01

    A compilation of analyses generated during the development of the electron-proton spectrometer for the Skylab program is presented. The data documents the analyses required by the electron-proton spectrometer verification plan. The verification plan was generated to satisfy the ancillary hardware requirements of the Apollo Applications program. The certification of the spectrometer requires that various tests, inspections, and analyses be documented, approved, and accepted by reliability and quality control personnel of the spectrometer development program.

  18. Electrical characteristics of high-power AlGaN-GaN high electron mobility transistors irradiated with protons and heavy ions

    NASA Astrophysics Data System (ADS)

    Sin, Yongkun; Bonsall, Jeremy; Lingley, Zachary; Brodie, Miles; Mason, Maribeth

    2017-02-01

    High electron mobility transistors (HEMTs) based on AlGaN-GaN hetero-structures are finding an increasing number of commercial and military applications that require high voltage, high power, and high efficiency operation. In recent years, leading GaN HEMT manufacturers have reported excellent RF power characteristics and encouraging reliability, but long-term reliability in the space environment still remains a major concern due to a large number of defects and traps present both in the bulk as well as at the surface, leading to undesirable characteristics including current collapse. Furthermore, degradation mechanisms in GaN HEMTs are still not well understood. Thus, reliability and radiation effects of GaN HEMTs should be studied before solid state power amplifiers (SSPAs) based on GaN HEMT technology are successfully deployed in space satellite systems. For the present study, we investigated electrical characteristics of high-power GaN HEMTs irradiated with protons and heavy ions under various irradiation and biasing conditions.

  19. Thermal Management and Reliability of Power Electronics and Electric Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narumanchi, Sreekant

    2016-09-19

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil - by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, andmore » in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines are presented.« less

  20. Investigation of electrochemical migration on Sn-0.7Cu-0.3Ag-0.03P-0.005Ni solder alloy in HNO3 solution

    NASA Astrophysics Data System (ADS)

    Sarveswaran, C.; Othman, N. K.; Ali, M. Yusuf Tura; Ani, F. Che; Samsudin, Z.

    2015-09-01

    Current issue in lead-free solder in term of its reliability is still under investigation. This high impact research attempts to investigate the electrochemical migration (ECM) on Sn-0.7Cu-0.3Ag-0.03P-0.005Ni solder alloy by Water Drop Test (WDT) in different concentration of HNO3 solution. The concentration of HNO3 solution used in this research was 0.05, 0.10, 0.50 and 1M. Optical Microscope (OM), Field Emission Scanning Electron Microscope (FESEM) and Energy Dispersive X-Ray Analysis (EDX) were carried out in order to analysis the ECM behavior based on the growth of dendrite formation after WDT. In general, the results demonstrated that dendrite growth is faster in higher concentration compared with low concentration of HNO3. The concentration of HNO3 solution used has a strong correlation with Mean-Time-To-Failure (MTTF). As the concentration of HNO3 increases, the MTTF value decreases. Based on the MTTF results the solder alloy in 1M HNO3 solution is most susceptible to ECM. SnO2 forms as a corrosion by-product in the samples proved by EDX analysis. The solder alloy poses a high reliability risk in microelectronic devices during operation in 1M HNO3 solution.

  1. Joint Lead-Free Solder Test Program for High Reliability Military and Space Applications

    NASA Technical Reports Server (NTRS)

    Brown, Christina

    2004-01-01

    Current and future space and defense systems face potential risks from the continued use of tin-lead solder, including: compliance with current environmental regulations, concerns about potential environmental legislation banning lead-containing products, reduced mission readiness, and component obsolescence with lead surface finishes. For example, the United States Environmental Protection Agency (USEPA) has lowered the Toxic Chemical Release reporting threshold for lead to 100 pounds. Overseas, the Waste Electrical and Electronic Equipment (WEEE) and the Restriction on Hazardous Substances (RoHS) Dicctives in Europe and similar mandates in Japan have instilled concern that a legislative body will prohibit the use of lead in aerospace/military electronics soldering. Any potential banning of lead compounds could reduce the supplier base and adversely affect the readiness of missions led by the National Aeronautics and Space Administration (NASA) and the U.S. Department of Defense (DoD). Before considering lead-free electronics for system upgrades or future designs, however, it is important for the DoD and NASA to know whether lead-free solders can meet their systems' requirements. No single lead-free solder is likely to qualify for all defense and space applications. Therefore, it is important to validate alternative solders for discrete applications. As a result of the need for comprehensive test data on the reliability of lead-free solders, a partnership was formed between the DoD, NASA, and several original equipment manufactures (OEMs) to conduct solder-joint reliability (laboratory) testing of three lead-free solder alloys on newly manufactured and reworked circuit cards to generate performance data for high-reliability (IPC Class 3) applications.

  2. Phosphorus as sintering activator in powder metallurgical steels: characterization of the distribution and its technological impact.

    PubMed

    Krecar, Dragan; Vassileva, Vassilka; Danninger, Herbert; Hutter, Herbert

    2004-06-01

    Powder metallurgy is a highly developed method of manufacturing reliable ferrous parts. The main processing steps in a powder metallurgical line are pressing and sintering. Sintering can be strongly enhanced by the formation of a liquid phase during the sintering process when using phosphorus as sintering activator. In this work the distribution (effect) of phosphorus was investigated by means of secondary ion mass spectrometry (SIMS) supported by Auger electron spectroscopy (AES) and electron probe micro analysis (EPMA). To verify the influence of the process conditions (phosphorus content, sintering atmosphere, time) on the mechanical properties, additional measurements of the microstructure (pore shape) and of impact energy were performed. Analysis of fracture surfaces was performed by means of scanning electron microscopy (SEM). The concentration of phosphorus differs in the samples from 0 to 1% (w/ w). Samples with higher phosphorus concentrations (1% (w/ w) and above) are also measurable by EPMA, whereas the distributions of P at technically relevant concentrations and the distribution of possible impurities are only detectable (visible) by means of SIMS. The influence of the sintering time on the phosphorus distribution will be demonstrated. In addition the grain boundary segregation of P was measured by AES at the surface of in-situ broken samples. It will be shown that the distribution of phosphorus depends also on the concentration of carbon in the samples.

  3. Integrating Reliability Analysis with a Performance Tool

    NASA Technical Reports Server (NTRS)

    Nicol, David M.; Palumbo, Daniel L.; Ulrey, Michael

    1995-01-01

    A large number of commercial simulation tools support performance oriented studies of complex computer and communication systems. Reliability of these systems, when desired, must be obtained by remodeling the system in a different tool. This has obvious drawbacks: (1) substantial extra effort is required to create the reliability model; (2) through modeling error the reliability model may not reflect precisely the same system as the performance model; (3) as the performance model evolves one must continuously reevaluate the validity of assumptions made in that model. In this paper we describe an approach, and a tool that implements this approach, for integrating a reliability analysis engine into a production quality simulation based performance modeling tool, and for modeling within such an integrated tool. The integrated tool allows one to use the same modeling formalisms to conduct both performance and reliability studies. We describe how the reliability analysis engine is integrated into the performance tool, describe the extensions made to the performance tool to support the reliability analysis, and consider the tool's performance.

  4. Preliminary Analysis of LORAN-C System Reliability for Civil Aviation.

    DTIC Science & Technology

    1981-09-01

    overviev of the analysis technique. Section 3 describes the computerized LORAN-C coverage model which is used extensively in the reliability analysis...Xth Plenary Assembly, Geneva, 1963, published by International Telecomunications Union. S. Braff, R., Computer program to calculate a Karkov Chain Reliability Model, unpublished york, MITRE Corporation. A-1 I.° , 44J Ili *Y 0E 00 ...F i8 1110 Prelim inary Analysis of Program Engineering & LORAN’C System ReliabilityMaintenance Service i ~Washington. D.C.

  5. Self-consistent multidimensional electron kinetic model for inductively coupled plasma sources

    NASA Astrophysics Data System (ADS)

    Dai, Fa Foster

    Inductively coupled plasma (ICP) sources have received increasing interest in microelectronics fabrication and lighting industry. In 2-D configuration space (r, z) and 2-D velocity domain (νθ,νz), a self- consistent electron kinetic analytic model is developed for various ICP sources. The electromagnetic (EM) model is established based on modal analysis, while the kinetic analysis gives the perturbed Maxwellian distribution of electrons by solving Boltzmann-Vlasov equation. The self- consistent algorithm combines the EM model and the kinetic analysis by updating their results consistently until the solution converges. The closed-form solutions in the analytical model provide rigorous and fast computing for the EM fields and the electron kinetic behavior. The kinetic analysis shows that the RF energy in an ICP source is extracted by a collisionless dissipation mechanism, if the electron thermovelocity is close to the RF phase velocities. A criterion for collisionless damping is thus given based on the analytic solutions. To achieve uniformly distributed plasma for plasma processing, we propose a novel discharge structure with both planar and vertical coil excitations. The theoretical results demonstrate improved uniformity for the excited azimuthal E-field in the chamber. Non-monotonic spatial decay in electric field and space current distributions was recently observed in weakly- collisional plasmas. The anomalous skin effect is found to be responsible for this phenomenon. The proposed model successfully models the non-monotonic spatial decay effect and achieves good agreements with the measurements for different applied RF powers. The proposed analytical model is compared with other theoretical models and different experimental measurements. The developed model is also applied to two kinds of ICP discharges used for electrodeless light sources. One structure uses a vertical internal coil antenna to excite plasmas and another has a metal shield to prevent the electromagnetic radiation. The theoretical results delivered by the proposed model agree quite well with the experimental measurements in many aspects. Therefore, the proposed self-consistent model provides an efficient and reliable means for designing ICP sources in various applications such as VLSI fabrication and electrodeless light sources.

  6. Electromechanical actuation for cryogenic valve control

    NASA Technical Reports Server (NTRS)

    Lister, M. J.; Reichmuth, D. M.

    1993-01-01

    The design and analysis of the electromechanical actuator (EMA) being developed for the NASA/Marshall Space Flight Center as part of the National Launch System (NLS) Propellant Control Effector Advanced Development Program (ADP) are addressed. The EMA design uses several proven technologies combined into a single modular package which includes single stage high ratio gear reduction, redundant electric motors mounted on a common drive shaft, redundant drive and control electronics, and digital technology for performing the closed loop position feedback, communication, and health monitoring functions. Results of tests aimed at evaluating both component characteristics and overall system performance demonstrated that the goal of low cost, reliable control in a cryogenic environment is feasible.

  7. Sensor fusion of phase measuring profilometry and stereo vision for three-dimensional inspection of electronic components assembled on printed circuit boards.

    PubMed

    Hong, Deokhwa; Lee, Hyunki; Kim, Min Young; Cho, Hyungsuck; Moon, Jeon Il

    2009-07-20

    Automatic optical inspection (AOI) for printed circuit board (PCB) assembly plays a very important role in modern electronics manufacturing industries. Well-developed inspection machines in each assembly process are required to ensure the manufacturing quality of the electronics products. However, generally almost all AOI machines are based on 2D image-analysis technology. In this paper, a 3D-measurement-method-based AOI system is proposed consisting of a phase shifting profilometer and a stereo vision system for assembled electronic components on a PCB after component mounting and the reflow process. In this system information from two visual systems is fused to extend the shape measurement range limited by 2pi phase ambiguity of the phase shifting profilometer, and finally to maintain fine measurement resolution and high accuracy of the phase shifting profilometer with the measurement range extended by the stereo vision. The main purpose is to overcome the low inspection reliability problem of 2D-based inspection machines by using 3D information of components. The 3D shape measurement results on PCB-mounted electronic components are shown and compared with results from contact and noncontact 3D measuring machines. Based on a series of experiments, the usefulness of the proposed sensor system and its fusion technique are discussed and analyzed in detail.

  8. ZnO nanoparticles via Moringa oleifera green synthesis: Physical properties & mechanism of formation

    NASA Astrophysics Data System (ADS)

    Matinise, N.; Fuku, X. G.; Kaviyarasu, K.; Mayedwa, N.; Maaza, M.

    2017-06-01

    The research work involves the development of better and reliable method for the bio-fabrication of Zinc oxide nanoparticles through green method using Moringa Oleifera extract as an effective chelating agent. The electrochemical activity, crystalline structure, morphology, isothermal behavior, chemical composition and optical properties of ZnO nanoparticles were studied using various characterization techniques i.e. Cyclic voltammetry (CV), X-ray powder diffraction (XRD), High resolution transmission electron microscopy (HRTEM), Selected area electron diffraction (SEAD), Differential scanning calorimetry/thermogravimetric analysis (DSC/TGA), Fourier Transform Infrared analysis (FTIR) and Ultraviolet spectroscopy studies (UV-vis). The electrochemical analysis proved that the ZnO nano has high electrochemical activity without any modifications and therefore are considered as a potential candidate in electrochemical applications. The XRD pattern confirmed the crystallinity and pure phase of the sample. DSC/TGA analysis of ZnO sample (before anneal) revealed three endothermic peaks around 140.8 °C, 223.7 °C and 389.5 °C. These endothermic peaks are attributed to the loss of volatile surfactant, conversion of zinc hydroxide to zinc oxide nanoparticles and transformation of zinc oxide into zinc nanoparticles. Mechanisms of formation of the ZnO nanoparticles via the chemical reaction of the Zinc nitrate precursor with the bioactive compounds of the Moringa oleifera are proposed for each of the major family compounds: Vitamins, Flavonoids, and Phenolic acids.

  9. Window for Optimal Frequency Operation and Reliability of 3DEG and 2DEG Channels for Oxide Microwave MESFETs and HFETs

    DTIC Science & Technology

    2016-04-01

    noise, and energy relaxation for doped zinc-oxide and structured ZnO transistor materials with a 2-D electron gas (2DEG) channel subjected to a strong...function on the time delay. Closed symbols represent the Monte Carlo data with hot-phonon effect at different electron gas density: 1•1017 cm-3...Monte Carlo simulation is performed for electron gas density of 1•1018 cm-3. Figure 18. Monte Carlo simulation of density-dependent hot-electron energy

  10. Comparative Analysis of the Reliability of Steel Structure with Pinned and Rigid Nodes Subjected to Fire

    NASA Astrophysics Data System (ADS)

    Kubicka, Katarzyna; Radoń, Urszula; Szaniec, Waldemar; Pawlak, Urszula

    2017-10-01

    The paper concerns the reliability analysis of steel structures subjected to high temperatures of fire gases. Two types of spatial structures were analysed, namely with pinned and rigid nodes. The fire analysis was carried out according to prescriptions of Eurocode. The static-strength analysis was conducted using the finite element method (FEM). The MES3D program, developed by Szaniec (Kielce University of Technology, Poland), was used for this purpose. The results received from MES3D made it possible to carry out the reliability analysis using the Numpress Explore program that was developed at the Institute of Fundamental Technological Research of the Polish Academy of Sciences [9]. The measurement of reliability of structures is the Hasofer-Lind reliability index (β). The reliability analysis was carried out according to approximation (FORM, SORM) and simulation (Importance Sampling, Monte Carlo) methods. As the fire progresses, the value of reliability index decreases. The analysis conducted for the study made it possible to evaluate the impact of node types on those changes. In real structures, it is often difficult to define correctly types of nodes, so some simplifications are made. The presented analysis contributes to the recognition of consequences of such assumptions for the safety of structures, subjected to fire.

  11. Overcoming the Challenges of Unstructured Data in Multi-site, Electronic Medical Record-based Abstraction

    PubMed Central

    Polnaszek, Brock; Gilmore-Bykovskyi, Andrea; Hovanes, Melissa; Roiland, Rachel; Ferguson, Patrick; Brown, Roger; Kind, Amy JH

    2014-01-01

    Background Unstructured data encountered during retrospective electronic medical record (EMR) abstraction has routinely been identified as challenging to reliably abstract, as this data is often recorded as free text, without limitations to format or structure. There is increased interest in reliably abstracting this type of data given its prominent role in care coordination and communication, yet limited methodological guidance exists. Objective As standard abstraction approaches resulted in sub-standard data reliability for unstructured data elements collected as part of a multi-site, retrospective EMR study of hospital discharge communication quality, our goal was to develop, apply and examine the utility of a phase-based approach to reliably abstract unstructured data. This approach is examined using the specific example of discharge communication for warfarin management. Research Design We adopted a “fit-for-use” framework to guide the development and evaluation of abstraction methods using a four step, phase-based approach including (1) team building, (2) identification of challenges, (3) adaptation of abstraction methods, and (4) systematic data quality monitoring. Measures Unstructured data elements were the focus of this study, including elements communicating steps in warfarin management (e.g., warfarin initiation) and medical follow-up (e.g., timeframe for follow-up). Results After implementation of the phase-based approach, inter-rater reliability for all unstructured data elements demonstrated kappas of ≥ 0.89 -- an average increase of + 0.25 for each unstructured data element. Conclusions As compared to standard abstraction methodologies, this phase-based approach was more time intensive, but did markedly increase abstraction reliability for unstructured data elements within multi-site EMR documentation. PMID:27624585

  12. Dynamic decision-making for reliability and maintenance analysis of manufacturing systems based on failure effects

    NASA Astrophysics Data System (ADS)

    Zhang, Ding; Zhang, Yingjie

    2017-09-01

    A framework for reliability and maintenance analysis of job shop manufacturing systems is proposed in this paper. An efficient preventive maintenance (PM) policy in terms of failure effects analysis (FEA) is proposed. Subsequently, reliability evaluation and component importance measure based on FEA are performed under the PM policy. A job shop manufacturing system is applied to validate the reliability evaluation and dynamic maintenance policy. Obtained results are compared with existed methods and the effectiveness is validated. Some vague understandings for issues such as network modelling, vulnerabilities identification, the evaluation criteria of repairable systems, as well as PM policy during manufacturing system reliability analysis are elaborated. This framework can help for reliability optimisation and rational maintenance resources allocation of job shop manufacturing systems.

  13. Computational methods for efficient structural reliability and reliability sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Wu, Y.-T.

    1993-01-01

    This paper presents recent developments in efficient structural reliability analysis methods. The paper proposes an efficient, adaptive importance sampling (AIS) method that can be used to compute reliability and reliability sensitivities. The AIS approach uses a sampling density that is proportional to the joint PDF of the random variables. Starting from an initial approximate failure domain, sampling proceeds adaptively and incrementally with the goal of reaching a sampling domain that is slightly greater than the failure domain to minimize over-sampling in the safe region. Several reliability sensitivity coefficients are proposed that can be computed directly and easily from the above AIS-based failure points. These probability sensitivities can be used for identifying key random variables and for adjusting design to achieve reliability-based objectives. The proposed AIS methodology is demonstrated using a turbine blade reliability analysis problem.

  14. Benchmarks and Reliable DFT Results for Spin Gaps of Small Ligand Fe(II) Complexes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Suhwan; Kim, Min-Cheol; Sim, Eunji

    2017-05-01

    All-electron fixed-node diffusion Monte Carlo provides benchmark spin gaps for four Fe(II) octahedral complexes. Standard quantum chemical methods (semilocal DFT and CCSD(T)) fail badly for the energy difference between their high- and low-spin states. Density-corrected DFT is both significantly more accurate and reliable and yields a consistent prediction for the Fe-Porphyrin complex

  15. Electronic Warfare and Radar Systems Engineering Handbook

    DTIC Science & Technology

    2012-06-01

    Airframe Missile, or Reliability, Availability, and Maintainability R&M Reliability and Maintainability RAT Ram Air Turbine RBOC Rapid Blooming...the Doppler shifted return (see Figure 10). Reflections off rotating jet engine compressor blades, aircraft propellers, ram air turbine (RAT...predict aircraft ground speed and direction of motion. Wind influences are taken into account, such that the radar can also be used to update the aircraft

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamiya, Shoji; Sato, Hisashi; Nishida, Masahiro

    Reliability of electronic devices has been an issue of serious importance. One of the potential factors to spoil the reliability is possible local drops of strength on the interface of multilayered structure. A new technique for the evaluation of local interface adhesion energy was applied to the interface between Cu and cap layer in a Cu damascene interconnect structure, in order to elucidate variation in adhesion strength as a function of measurement location.

  17. Reliability and testing

    NASA Technical Reports Server (NTRS)

    Auer, Werner

    1996-01-01

    Reliability and its interdependence with testing are important topics for development and manufacturing of successful products. This generally accepted fact is not only a technical statement, but must be also seen in the light of 'Human Factors.' While the background for this paper is the experience gained with electromechanical/electronic space products, including control and system considerations, it is believed that the content could be also of interest for other fields.

  18. Psychometrics of a new questionnaire to assess glaucoma adherence: the Glaucoma Treatment Compliance Assessment Tool (an American Ophthalmological Society thesis).

    PubMed

    Mansberger, Steven L; Sheppler, Christina R; McClure, Tina M; Vanalstine, Cory L; Swanson, Ingrid L; Stoumbos, Zoey; Lambert, William E

    2013-09-01

    To report the psychometrics of the Glaucoma Treatment Compliance Assessment Tool (GTCAT), a new questionnaire designed to assess adherence with glaucoma therapy. We developed the questionnaire according to the constructs of the Health Belief Model. We evaluated the questionnaire using data from a cross-sectional study with focus groups (n = 20) and a prospective observational case series (n=58). Principal components analysis provided assessment of construct validity. We repeated the questionnaire after 3 months for test-retest reliability. We evaluated predictive validity using an electronic dosing monitor as an objective measure of adherence. Focus group participants provided 931 statements related to adherence, of which 88.7% (826/931) could be categorized into the constructs of the Health Belief Model. Perceived barriers accounted for 31% (288/931) of statements, cues-to-action 14% (131/931), susceptibility 12% (116/931), benefits 12% (115/931), severity 10% (91/931), and self-efficacy 9% (85/931). The principal components analysis explained 77% of the variance with five components representing Health Belief Model constructs. Reliability analyses showed acceptable Cronbach's alphas (>.70) for four of the seven components (severity, susceptibility, barriers [eye drop administration], and barriers [discomfort]). Predictive validity was high, with several Health Belief Model questions significantly associated (P <.05) with adherence and a correlation coefficient (R (2)) of .40. Test-retest reliability was 90%. The GTCAT shows excellent repeatability, content, construct, and predictive validity for glaucoma adherence. A multisite trial is needed to determine whether the results can be generalized and whether the questionnaire accurately measures the effect of interventions to increase adherence.

  19. Meta-Analysis of Scale Reliability Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko; Marcoulides, George A.

    2013-01-01

    A latent variable modeling approach is outlined that can be used for meta-analysis of reliability coefficients of multicomponent measuring instruments. Important limitations of efforts to combine composite reliability findings across multiple studies are initially pointed out. A reliability synthesis procedure is discussed that is based on…

  20. The Impact Analysis of Psychological Reliability of Population Pilot Study for Selection of Particular Reliable Multi-Choice Item Test in Foreign Language Research Work

    ERIC Educational Resources Information Center

    Fazeli, Seyed Hossein

    2010-01-01

    The purpose of research described in the current study is the psychological reliability, its importance, application, and more to investigate on the impact analysis of psychological reliability of population pilot study for selection of particular reliable multi-choice item test in foreign language research work. The population for subject…

  1. Incident learning in pursuit of high reliability: implementing a comprehensive, low-threshold reporting program in a large, multisite radiation oncology department.

    PubMed

    Gabriel, Peter E; Volz, Edna; Bergendahl, Howard W; Burke, Sean V; Solberg, Timothy D; Maity, Amit; Hahn, Stephen M

    2015-04-01

    Incident learning programs have been recognized as cornerstones of safety and quality assurance in so-called high reliability organizations in industries such as aviation and nuclear power. High reliability organizations are distinguished by their drive to continuously identify and proactively address a broad spectrum of latent safety issues. Many radiation oncology institutions have reported on their experience in tracking and analyzing adverse events and near misses but few have incorporated the principles of high reliability into their programs. Most programs have focused on the reporting and retrospective analysis of a relatively small number of significant adverse events and near misses. To advance a large, multisite radiation oncology department toward high reliability, a comprehensive, cost-effective, electronic condition reporting program was launched to enable the identification of a broad spectrum of latent system failures, which would then be addressed through a continuous quality improvement process. A comprehensive program, including policies, work flows, and information system, was designed and implemented, with use of a low reporting threshold to focus on precursors to adverse events. In a 46-month period from March 2011 through December 2014, a total of 8,504 conditions (average, 185 per month, 1 per patient treated, 3.9 per 100 fractions [individual treatments]) were reported. Some 77.9% of clinical staff members reported at least 1 condition. Ninety-eight percent of conditions were classified in the lowest two of four severity levels, providing the opportunity to address conditions before they contribute to adverse events. Results after approximately four years show excellent employee engagement, a sustained rate of reporting, and a focus on low-level issues leading to proactive quality improvement interventions.

  2. Reliability of clinical impact grading by healthcare professionals of common prescribing error and optimisation cases in critical care patients.

    PubMed

    Bourne, Richard S; Shulman, Rob; Tomlin, Mark; Borthwick, Mark; Berry, Will; Mills, Gary H

    2017-04-01

    To identify between and within profession-rater reliability of clinical impact grading for common critical care prescribing error and optimisation cases. To identify representative clinical impact grades for each individual case. Electronic questionnaire. 5 UK NHS Trusts. 30 Critical care healthcare professionals (doctors, pharmacists and nurses). Participants graded severity of clinical impact (5-point categorical scale) of 50 error and 55 optimisation cases. Case between and within profession-rater reliability and modal clinical impact grading. Between and within profession rater reliability analysis used linear mixed model and intraclass correlation, respectively. The majority of error and optimisation cases (both 76%) had a modal clinical severity grade of moderate or higher. Error cases: doctors graded clinical impact significantly lower than pharmacists (-0.25; P < 0.001) and nurses (-0.53; P < 0.001), with nurses significantly higher than pharmacists (0.28; P < 0.001). Optimisation cases: doctors graded clinical impact significantly lower than nurses and pharmacists (-0.39 and -0.5; P < 0.001, respectively). Within profession reliability grading was excellent for pharmacists (0.88 and 0.89; P < 0.001) and doctors (0.79 and 0.83; P < 0.001) but only fair to good for nurses (0.43 and 0.74; P < 0.001), for optimisation and error cases, respectively. Representative clinical impact grades for over 100 common prescribing error and optimisation cases are reported for potential clinical practice and research application. The between professional variability highlights the importance of multidisciplinary perspectives in assessment of medication error and optimisation cases in clinical practice and research. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  3. A Mixed-methods Study to Assess Interrater Reliability and Nurse Perception of the Braden Scale in a Tertiary Acute Care Setting.

    PubMed

    Ho, Chester H; Cheung, Amanda; Southern, Danielle; Ocampo, Wrechelle; Kaufman, Jaime; Hogan, David B; Baylis, Barry; Conly, John M; Stelfox, Henry T; Ghali, William A

    2016-12-01

    Research regarding the reliability of the Braden Scale and nurses' perspectives on the instrument for predicting pressure ulcer (PU) risk in acute care settings is limited. A mixed-methods study was conducted in a tertiary acute care facility to examine interrater reliability (IRR) of the Braden Scale and its subscales, and a qualitative survey using semi-structured interviews was conducted among nurses caring for patients in acute care units to gain nurse perspective regarding scale usability. Data were extracted from a previous retrospective, randomized, controlled trial involving adult patients with compromised mobility receiving care in a tertiary acute care hospital in Canada. One-way, intraclass correlation coefficients (ICCs) were calculated on item and total scores, and kappa statistics were used to determine reliability of categorizing patients on their risk. Interview results were categorized by common themes. Reliability was assessed on 64 patients, where nurses and research staff independently assessed enrolled participants at baseline and after 72 hours using the Braden Scale as it appeared on an electronic medical record. IRR for the total score was high (ICC = 0.807). The friction and shear item had the lowest reliability (ICC = 0.266). Reliability of categorizing patients' level of risk had moderate agreement (κ = 0.408). Three (3) major and 12 subthemes emerged from the 14 nurse interviews; nurses were aware of the scale's purpose but were uncertain of its effectiveness, some items were difficult to rate, and questions were raised as to whether using the scale enhanced patient care. Aspects identified by nurses to enhance usability included: 1) changes to the electronic version (incorporating the scale into daily assessment documents with readily available item descriptions), 2) additional training, and 3) easily available resource material to improve reliability and usability of scale. These findings need to be considered when using the Braden Scale in clinical practice. Further study of the value of the total Braden Scale and its subscales is warranted.

  4. Electronics-X: A Study of Military Electronics with Particular Reference to Cost and Reliability. Volume 2: Complete Report

    DTIC Science & Technology

    1974-01-01

    also makes the Government vulner- able to upward price pressures by the selected supplier and induces design stagnation. % • The potential benefit of...following modifications: 1. It should specifically permit consideration of changes that are of benefit to the contractor and not detrimen- tal to...vali- dated by experience, that competition throughout the electronic-system life-cycle process will, on the whole, yield great benefits in

  5. Time-Dependent Thomas-Fermi Approach for Electron Dynamics in Metal Clusters

    NASA Astrophysics Data System (ADS)

    Domps, A.; Reinhard, P.-G.; Suraud, E.

    1998-06-01

    We propose a time-dependent Thomas-Fermi approach to the (nonlinear) dynamics of many-fermion systems. The approach relies on a hydrodynamical picture describing the system in terms of collective flow. We investigate in particular an application to electron dynamics in metal clusters. We make extensive comparisons with fully fledged quantal dynamical calculations and find overall good agreement. The approach thus provides a reliable and inexpensive scheme to study the electronic response of large metal clusters.

  6. Accurate monoenergetic electron parameters of laser wakefield in a bubble model

    NASA Astrophysics Data System (ADS)

    Raheli, A.; Rahmatallahpur, S. H.

    2012-11-01

    A reliable analytical expression for the potential of plasma waves with phase velocities near the speed of light is derived. The presented spheroid cavity model is more consistent than the previous spherical and ellipsoidal model and it explains the mono-energetic electron trajectory more accurately, especially at the relativistic region. As a result, the quasi-mono-energetic electrons output beam interacting with the laser plasma can be more appropriately described with this model.

  7. Regional model-based computerized ionospheric tomography using GPS measurements: IONOLAB-CIT

    NASA Astrophysics Data System (ADS)

    Tuna, Hakan; Arikan, Orhan; Arikan, Feza

    2015-10-01

    Three-dimensional imaging of the electron density distribution in the ionosphere is a crucial task for investigating the ionospheric effects. Dual-frequency Global Positioning System (GPS) satellite signals can be used to estimate the slant total electron content (STEC) along the propagation path between a GPS satellite and ground-based receiver station. However, the estimated GPS-STEC is very sparse and highly nonuniformly distributed for obtaining reliable 3-D electron density distributions derived from the measurements alone. Standard tomographic reconstruction techniques are not accurate or reliable enough to represent the full complexity of variable ionosphere. On the other hand, model-based electron density distributions are produced according to the general trends of ionosphere, and these distributions do not agree with measurements, especially for geomagnetically active hours. In this study, a regional 3-D electron density distribution reconstruction method, namely, IONOLAB-CIT, is proposed to assimilate GPS-STEC into physical ionospheric models. The proposed method is based on an iterative optimization framework that tracks the deviations from the ionospheric model in terms of F2 layer critical frequency and maximum ionization height resulting from the comparison of International Reference Ionosphere extended to Plasmasphere (IRI-Plas) model-generated STEC and GPS-STEC. The suggested tomography algorithm is applied successfully for the reconstruction of electron density profiles over Turkey, during quiet and disturbed hours of ionosphere using Turkish National Permanent GPS Network.

  8. The Internet School of Medicine: use of electronic resources by medical trainees and the reliability of those resources.

    PubMed

    Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K

    2015-01-01

    Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half of the time and have an alarmingly high rate of inaccurate information. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  9. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 4: HARP Output (HARPO) graphics display user's guide

    NASA Technical Reports Server (NTRS)

    Sproles, Darrell W.; Bavuso, Salvatore J.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.

  10. Electron beam influence on the carbon contamination of electron irradiated hydroxyapatite thin films

    NASA Astrophysics Data System (ADS)

    Hristu, Radu; Stanciu, Stefan G.; Tranca, Denis E.; Stanciu, George A.

    2015-08-01

    Electron beam irradiation which is considered a reliable method for tailoring the surface charge of hydroxyapatite is hindered by carbon contamination. Separating the effects of the carbon contamination from those of irradiation-induced trapped charge is important for a wide range of biological applications. In this work we focus on the understanding of the electron-beam-induced carbon contamination with special emphasis on the influence of the electron irradiation parameters on this phenomenon. Phase imaging in atomic force microscopy is used to evaluate the influence of electron energy, beam current and irradiation time on the shape and size of the resulted contamination patterns. Different processes involved in the carbon contamination of hydroxyapatite are discussed.

  11. Is the MARS questionnaire a reliable measure of medication adherence in childhood asthma?

    PubMed

    Garcia-Marcos, Patricia W; Brand, Paul L P; Kaptein, Adrian A; Klok, Ted

    2016-12-01

    To assess the reliability of the Medication Adherence Report Scale (MARS-5) for assessing adherence in clinical practice and research. Prospective cohort study following electronically measured inhaled corticosteroids (ICS) adherence for 1 year in 2-13-year-old children with persistent asthma. The relationship between electronically measured adherence and MARS-5 scores (ranging from 5 to 25) was assessed by Spearman's rank correlation coefficient. A ROC (receiver operating characteristic) curve was performed testing MARS-5 against electronically measured adherence. Sensitivity, specificity, positive and negative likelihood ratios of the closest MARS-5 cut-off values to the top left-hand corner of the ROC curve were calculated. High MARS scores were obtained (median 24, interquartile range 22-24). Despite a statistically significant correlation between MARS-5 and electronically assessed adherence (Spearman's rho = 0.47; p < 0.0001), there was considerable variation of adherence rates at every MARS-5 score. The area under the ROC curve was 0.7188. A MARS-5 score ≥23 had the best predictive ability for electronically assessed adherence, but positive and negative likelihood ratios were too small to be useful (1.65 and 0.27, respectively). Self-report using MARS-5 is too inaccurate to be a useful measure of adherence in children with asthma, both in clinical practice and in research.

  12. Theory of runaway electrons in ITER: Equations, important parameters, and implications for mitigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boozer, Allen H., E-mail: ahb17@columbia.edu

    2015-03-15

    The plasma current in ITER cannot be allowed to transfer from thermal to relativistic electron carriers. The potential for damage is too great. Before the final design is chosen for the mitigation system to prevent such a transfer, it is important that the parameters that control the physics be understood. Equations that determine these parameters and their characteristic values are derived. The mitigation benefits of the injection of impurities with the highest possible atomic number Z and the slowing plasma cooling during halo current mitigation to ≳40 ms in ITER are discussed. The highest possible Z increases the poloidal flux consumptionmore » required for each e-fold in the number of relativistic electrons and reduces the number of high energy seed electrons from which exponentiation builds. Slow cooling of the plasma during halo current mitigation also reduces the electron seed. Existing experiments could test physics elements required for mitigation but cannot carry out an integrated demonstration. ITER itself cannot carry out an integrated demonstration without excessive danger of damage unless the probability of successful mitigation is extremely high. The probability of success depends on the reliability of the theory. Equations required for a reliable Monte Carlo simulation are derived.« less

  13. Investigation of radiation-induced free radicals and luminescence properties in fresh pomegranate fruits.

    PubMed

    Shahbaz, Hafiz M; Akram, Kashif; Ahn, Jae-Jun; Kwon, Joong-Ho

    2013-05-01

    Radiation-induced free radicals and luminescence properties were investigated in γ-irradiated (0-3 kGy) pomegranate ( Punica granatum L.) fruits. Photostimulated luminescence (PSL) analysis showed limited applicability, and only 3 kGy-irradiated pomegranates showed positive PSL values (>5000 PCs). Thermoluminescence (TL) glow curve features, such as intensity and the presence of maximum glow peak in radiation-specific temperature range (150-250 °C), provided definite proof of irradiation, and the TL ratios (TL1/TL2) also confirmed the reliability of TL results. Scanning electron microscopy energy dispersive X-ray (SEM-EDX) analysis of the separated minerals showed that feldspar and quartz minerals were responsible for the luminescence properties. Radiation-induced cellulose radicals were detected in the seeds and rinds by ESR analysis. The ESR results were better in freeze-dried samples than in alcohol-extracted ones. A positive correlation was found between the ESR and TL signal intensities and irradiation doses; however, the most promising detection of the irradiation status was possible through TL analysis.

  14. p Ka determinations of xanthene derivates in aqueous solutions by multivariate analysis applied to UV-Vis spectrophotometric data

    NASA Astrophysics Data System (ADS)

    Batistela, Vagner Roberto; Pellosi, Diogo Silva; de Souza, Franciane Dutra; da Costa, Willian Ferreira; de Oliveira Santin, Silvana Maria; de Souza, Vagner Roberto; Caetano, Wilker; de Oliveira, Hueder Paulo Moisés; Scarminio, Ieda Spacino; Hioka, Noboru

    2011-09-01

    Xanthenes form to an important class of dyes which are widely used. Most of them present three acid-base groups: two phenolic sites and one carboxylic site. Therefore, the p Ka determination and the attribution of each group to the corresponding p Ka value is a very important feature. Attempts to obtain reliable p Ka through the potentiometry titration and the electronic absorption spectrophotometry using the first and second orders derivative failed. Due to the close p Ka values allied to strong UV-Vis spectral overlap, multivariate analysis, a powerful chemometric method, is applied in this work. The determination was performed for eosin Y, erythrosin B, and bengal rose B, and also for other synthesized derivatives such as 2-(3,6-dihydroxy-9-acridinyl) benzoic acid, 2,4,5,7-tetranitrofluorescein, eosin methyl ester, and erythrosin methyl ester in water. These last two compounds (esters) permitted to attribute the p Ka of the phenolic group, which is not easily recognizable for some investigated dyes. Besides the p Ka determination, the chemometry allowed for estimating the electronic spectrum of some prevalent protolytic species and the substituents effects evaluation.

  15. Development and Psychometric Testing of a Novel Food Service Satisfaction Questionnaire for Food Service Staff of Aged Care Homes.

    PubMed

    Miller, M; Hamilton, J; Scupham, R; Matwiejczyk, L; Prichard, I; Farrer, O; Yaxley, A

    2018-01-01

    Food service staff are integral to delivery of quality food in aged care homes yet measurement of their satisfaction is unable to be performed due to an absence of a valid and reliable questionnaire. The aim of this study was to develop and perform psychometric testing for a new Food Service Satisfaction Questionnaire developed in Australia specifically for use by food service staff working in residential aged care homes (Flinders FSSQFSAC). A mixed methods design utilizing both a qualitative (in-depth interviews, focus groups) and a quantitative approach (cross sectional survey) was used. Content validity was determined from focus groups and interviews with food service staff currently working in aged care homes, related questionnaires from the literature and consultation with an expert panel. The questionnaire was tested for construct validity and internal consistency using data from food service staff currently working in aged care homes that responded to an electronic invitation circulated to Australian aged care homes using a national database of email addresses. Construct validity was tested via principle components analysis and internal consistency through Cronbach's alpha. Temporal stability of the questionnaire was determined from food service staff undertaking the Flinders FSSQFSAC on two occasions, two weeks apart, and analysed using Pearson's correlations. Content validity for the Flinders FSSQFSAC was established from a panel of experts and stakeholders. Principle components analysis revealed food service staff satisfaction was represented by 61-items divided into eight domains: job satisfaction (α=0.832), food quality (α=0.871), staff training (α=0.922), consultation (α=0.840), eating environment (α=0.777), reliability (α=0.695), family expectations (α=0.781) and resident relationships (α=0.429), establishing construct validity in all domains, and internal consistency in all (α>0.5) except for "resident relationships" (α=0.429). Test-retest reliability coefficients ranged from 0.276 to 0.826 dependent on domain, with test-retest reliability established in seven domains at r>0.4; an exception was "reliability" at r=0.276. The newly developed Flinders FSSQFSAC has acceptable validity and reliability and thereby the potential to measure satisfaction of food service staff working in residential aged care homes, identify areas for strategic change, measure improvements and in turn, improve the satisfaction and quality of life of both food service staff and residents of aged care homes.

  16. Electronic cooling design and test validation

    NASA Astrophysics Data System (ADS)

    Murtha, W. B.

    1983-07-01

    An analytical computer model has been used to design a counterflow air-cooled heat exchanger according to the cooling, structural and geometric requirements of a U.S. Navy shipboard electronics cabinet, emphasizing high reliability performance through the maintenance of electronic component junction temperatures lower than 110 C. Environmental testing of the design obtained has verified that the analytical predictions were conservative. Model correlation to the test data furnishes an upgraded capability for the evaluation of tactical effects, and has established a two-orders of magnitude growth potential for increased electronics capabilities through enhanced heat dissipation. Electronics cabinets of this type are destined for use with Vertical Launching System-type combatant vessel magazines.

  17. Effects of Nitrogen and Hydrogen Codoping on the Electrical Performance and Reliability of InGaZnO Thin-Film Transistors.

    PubMed

    Abliz, Ablat; Gao, Qingguo; Wan, Da; Liu, Xingqiang; Xu, Lei; Liu, Chuansheng; Jiang, Changzhong; Li, Xuefei; Chen, Huipeng; Guo, Tailiang; Li, Jinchai; Liao, Lei

    2017-03-29

    Despite intensive research on improvement in electrical performances of ZnO-based thin-film transistors (TFTs), the instability issues have limited their applications for complementary electronics. Herein, we have investigated the effect of nitrogen and hydrogen (N/H) codoping on the electrical performance and reliability of amorphous InGaZnO (α-IGZO) TFTs. The performance and bias stress stability of α-IGZO device were simultaneously improved by N/H plasma treatment with a high field-effect mobility of 45.3 cm 2 /(V s) and small shifts of threshold voltage (V th ). On the basis of X-ray photoelectron spectroscopy analysis, the improved electrical performances of α-IGZO TFT should be attributed to the appropriate amount of N/H codoping, which could not only control the V th and carrier concentration efficiently, but also passivate the defects such as oxygen vacancy due to the formation of stable Zn-N and N-H bonds. Meanwhile, low-frequency noise analysis indicates that the average trap density near the α-IGZO/SiO 2 interface is reduced by the nitrogen and hydrogen plasma treatment. This method could provide a step toward the development of α-IGZO TFTs for potential applications in next-generation high-definition optoelectronic displays.

  18. Low Temperature Testing of a Radiation Hardened CMOS 8-Bit Flash Analog-to-Digital (A/D) Converter

    NASA Technical Reports Server (NTRS)

    Gerber, Scott S.; Hammond, Ahmad; Elbuluk, Malik E.; Patterson, Richard L.; Overton, Eric; Ghaffarian, Reza; Ramesham, Rajeshuni; Agarwal, Shri G.

    2001-01-01

    Power processing electronic systems, data acquiring probes, and signal conditioning circuits are required to operate reliably under harsh environments in many of NASA:s missions. The environment of the space mission as well as the operational requirements of some of the electronic systems, such as infrared-based satellite or telescopic observation stations where cryogenics are involved, dictate the utilization of electronics that can operate efficiently and reliably at low temperatures. In this work, radiation-hard CMOS 8-bit flash A/D converters were characterized in terms of voltage conversion and offset in the temperature range of +25 to -190 C. Static and dynamic supply currents, ladder resistance, and gain and offset errors were also obtained in the temperature range of +125 to -190 C. The effect of thermal cycling on these properties for a total of ten cycles between +80 and - 150 C was also determined. The experimental procedure along with the data obtained are reported and discussed in this paper.

  19. Electrically induced spontaneous emission in open electronic system

    NASA Astrophysics Data System (ADS)

    Wang, Rulin; Zhang, Yu; Yam, Chiyung; Computation Algorithms Division (CSRC) Team; Theoretical; Computational Chemistry (HKU) Collaboration

    A quantum mechanical approach is formulated for simulation of electroluminescence process in open electronic system. Based on nonequilibrium Green's function quantum transport equations and combining with photon-electron interaction, this method is used to describe electrically induced spontaneous emission caused by electron-hole recombination. The accuracy and reliability of simulation depends critically on correct description of the electronic band structure and the electron occupancy in the system. In this work, instead of considering electron-hole recombination in discrete states in the previous work, we take continuous states into account to simulate the spontaneous emission in open electronic system, and discover that the polarization of emitted photon is closely related to its propagation direction. Numerical studies have been performed to silicon nanowire-based P-N junction with different bias voltage.

  20. Reliability and validity of procedure-based assessments in otolaryngology training.

    PubMed

    Awad, Zaid; Hayden, Lindsay; Robson, Andrew K; Muthuswamy, Keerthini; Tolley, Neil S

    2015-06-01

    To investigate the reliability and construct validity of procedure-based assessment (PBA) in assessing performance and progress in otolaryngology training. Retrospective database analysis using a national electronic database. We analyzed PBAs of otolaryngology trainees in North London from core trainees (CTs) to specialty trainees (STs). The tool contains six multi-item domains: consent, planning, preparation, exposure/closure, technique, and postoperative care, rated as "satisfactory" or "development required," in addition to an overall performance rating (pS) of 1 to 4. Individual domain score, overall calculated score (cS), and number of "development-required" items were calculated for each PBA. Receiver operating characteristic analysis helped determine sensitivity and specificity. There were 3,152 otolaryngology PBAs from 46 otolaryngology trainees analyzed. PBA reliability was high (Cronbach's α 0.899), and sensitivity approached 99%. cS correlated positively with pS and level in training (rs : +0.681 and +0.324, respectively). ST had higher cS and pS than CT (93% ± 0.6 and 3.2 ± 0.03 vs. 71% ± 3.1 and 2.3 ± 0.08, respectively; P < .001). cS and pS increased from CT1 to ST8 showing construct validity (rs : +0.348 and +0.354, respectively; P < .001). The technical skill domain had the highest utilization (98% of PBAs) and was the best predictor of cS and pS (rs : +0.96 and +0.66, respectively). PBA is reliable and valid for assessing otolaryngology trainees' performance and progress at all levels. It is highly sensitive in identifying competent trainees. The tool is used in a formative and feedback capacity. The technical domain is the best predictor and should be given close attention. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  1. EM calibration based on Post OPC layout analysis

    NASA Astrophysics Data System (ADS)

    Sreedhar, Aswin; Kundu, Sandip

    2010-03-01

    Design for Manufacturability (DFM) involves changes to the design and CAD tools to help increase pattern printability and improve process control. Design for Reliability (DFR) performs the same to improve reliability of devices from failures such as Electromigration (EM), gate-oxide break down, hot carrier injection (HCI), Negative Bias Temperature Insatiability (NBTI) and mechanical stress effects. Electromigration (EM) occurs due to migration or displacement of atoms as a result of the movement of electrons through a conducting medium. The rate of migration determines the Mean Time to Failure (MTTF) which is modeled as a function of temperature and current density. The model itself is calibrated through failure analysis (FA) of parts that are deemed to have failed due to EM against design parameters such as linewidth. Reliability Verification (RV) of a design involves verifying that every conducting line in a design meets certain MTTF threshold. In order to perform RV, current density for each wire must be computed. Current itself is a function of the parasitics that are determined through RC extraction. The standard practice is to perform the RC extraction and current density calculation on drawn, pre-OPC layouts. If a wire fails to meet threshold for MTTF, it may be resized. Subsequently, mask preparation steps such as OPC and PSM introduce extra features such as SRAFs, jogs,hammerheads and serifs that change their resistance, capacitance and current density values. Hence, calibrating EM model based on pre-OPC layouts will lead to different results compared to post-OPC layouts. In this work, we compare EM model calibration and reliability check based on drawn layout versus predicted layout, where the drawn layout is pre-OPC layout and predicted layout is based on litho simulation of post-OPC layout. Results show significant divergence between these two approaches, making a case for methodology based on predicted layout.

  2. Impact evaluation of conducted UWB transients on loads in power-line networks

    NASA Astrophysics Data System (ADS)

    Li, Bing; Månsson, Daniel

    2017-09-01

    Nowadays, faced with the ever-increasing dependence on diverse electronic devices and systems, the proliferation of potential electromagnetic interference (EMI) becomes a critical threat for reliable operation. A typical issue is the electronics working reliably in power-line networks when exposed to electromagnetic environment. In this paper, we consider a conducted ultra-wideband (UWB) disturbance, as an example of intentional electromagnetic interference (IEMI) source, and perform the impact evaluation at the loads in a network. With the aid of fast Fourier transform (FFT), the UWB transient is characterized in the frequency domain. Based on a modified Baum-Liu-Tesche (BLT) method, the EMI received at the loads, with complex impedance, is computed. Through inverse FFT (IFFT), we obtain time-domain responses of the loads. To evaluate the impact on loads, we employ five common, but important quantifiers, i.e., time-domain peak, total signal energy, peak signal power, peak time rate of change and peak time integral of the pulse. Moreover, to perform a comprehensive analysis, we also investigate the effects of the attributes (capacitive, resistive, or inductive) of other loads connected to the network, the rise time and pulse width of the UWB transient, and the lengths of power lines. It is seen that, for the loads distributed in a network, the impact evaluation of IEMI should be based on the characteristics of the IEMI source, and the network features, such as load impedances, layout, and characteristics of cables.

  3. T-shaped emitter metal heterojunction bipolar transistors for submillimeter wave applications

    NASA Technical Reports Server (NTRS)

    Fung, Andy; Samoska, Lorene; Velebir, Jim; Siege, Peter; Rodwell, Mark; Paidi, Vamsi; Griffth, Zach; Urteaga, Miguel; Malik, Roger

    2004-01-01

    We report on the development of submillimeter wave transistors at JPL. The goal of the effort is to produce advance-reliable high frequency and high power amplifiers, voltage controlled oscillators, active multipliers, and high-speed mixed-signal circuits for space borne applications. The technology in development to achieve this is based on the Indium Phosphide (InP) Heterojunction Bipolar Transistor (HBT). The HBT is well suited for high speed, high power and uniform (across wafer) performance, due to the ability to tailor the material structure that electrons traverse through by well-controlled epitaxial growth methods. InP with its compatible lattice matched alloys such as indium gallium arsenide (InGaAs) and indium aluminium arsenide (InAlAs) provides for high electron velocities and high voltage breakdown capabilities. The epitaxial methods for this material system are fairly mature, however the implementation of high performance and reliable transistors are still under development by many laboratories. Our most recently fabricated, second generation mesa HBTs at JPL have extrapolated current gain cutoff frequency (FJ of 142GHz and power gain cutoff frequency (Fm,) of approximately 160GHz. This represents a 13% and 33% improvement of Ft and F, respectively, compared to the first generation mesa HBTs [l]. Analysis based on the University of California, Santa Barbara (UCSB) device model, RF device characteristics can be significantly improved by reducing base contact resistance and base metal contact width. We will describe our effort towards increasing transistor performance and yield.

  4. Investigating the Reliability and Factor Structure of Kalichman's "Survey 2: Research Misconduct" Questionnaire: A Post Hoc Analysis Among Biomedical Doctoral Students in Scandinavia.

    PubMed

    Holm, Søren; Hofmann, Bjørn

    2017-10-01

    A precondition for reducing scientific misconduct is evidence about scientists' attitudes. We need reliable survey instruments, and this study investigates the reliability of Kalichman's "Survey 2: research misconduct" questionnaire. The study is a post hoc analysis of data from three surveys among biomedical doctoral students in Scandinavia (2010-2015). We perform reliability analysis, and exploratory and confirmatory factor analysis using a split-sample design as a partial validation. The results indicate that a reliable 13-item scale can be formed (Cronbach's α = .705), and factor analysis indicates that there are four reliable subscales each tapping a different construct: (a) general attitude to misconduct (α = .768), (b) attitude to personal misconduct (α = .784), (c) attitude to whistleblowing (α = .841), and (d) attitude to blameworthiness/punishment (α = .877). A full validation of the questionnaire requires further research. We, nevertheless, hope that the results will facilitate the increased use of the questionnaire in research.

  5. MIL-HDBK-338-Environmental Conversion Table Correction

    NASA Technical Reports Server (NTRS)

    Hark, Frank; Novack, Steve

    2017-01-01

    In reliability analysis for space launch vehicles, limited data is frequently a challenge due to the pure number of launches. A common solution is to use surrogate historical data of similar components from other industries (military data). The operating environment of the common data may be different from that of the necessary target analysis. The military electronic design handbook (MIL-HDBK-338) has a table for converting Mean Time Between Failure (MTBF) data from one environment to another. However, the table has some discrepancies and rounding of complementary conversions; namely going from environment A to B does not given the same result as going from B to A. This presentation will show the discrepancies in the original conversation table, the greater than expected magnitude, the problem with the updated published table and a suggested corrected table to reference when doing MTBF data environment conversion.

  6. Reliability of intensive care unit admitting and comorbid diagnoses, race, elements of Acute Physiology and Chronic Health Evaluation II score, and predicted probability of mortality in an electronic intensive care unit database.

    PubMed

    Wenner, Joshua B; Norena, Monica; Khan, Nadia; Palepu, Anita; Ayas, Najib T; Wong, Hubert; Dodek, Peter M

    2009-09-01

    Although reliability of severity of illness and predicted probability of hospital mortality have been assessed, interrater reliability of the abstraction of primary and other intensive care unit (ICU) admitting diagnoses and underlying comorbidities has not been studied. Patient data from one ICU were originally abstracted and entered into an electronic database by an ICU nurse. A research assistant reabstracted patient demographics, ICU admitting diagnoses and underlying comorbidities, and elements of Acute Physiology and Chronic Health Evaluation II (APACHE II) score from 100 random patients of 474 admitted during 2005 using an identical electronic database. Chamberlain's percent positive agreement was used to compare diagnoses and comorbidities between the 2 data abstractors. A kappa statistic was calculated for demographic variables, Glasgow Coma Score, APACHE II chronic health points, and HIV status. Intraclass correlation was calculated for acute physiology points and predicted probability of hospital mortality. Percent positive agreement for ICU primary and other admitting diagnoses ranged from 0% (primary brain injury) to 71% (sepsis), and for underlying comorbidities, from 40% (coronary artery bypass graft) to 100% (HIV). Agreement as measured by kappa statistic was strong for race (0.81) and age points (0.95), moderate for chronic health points (0.50) and HIV (0.66), and poor for Glasgow Coma Score (0.36). Intraclass correlation showed a moderate-high agreement for acute physiology points (0.88) and predicted probability of hospital mortality (0.71). Reliability for ICU diagnoses and elements of the APACHE II score is related to the objectivity of primary data in the medical charts.

  7. Electronic synoptic operative reporting: assessing the reliability and completeness of synoptic reports for pancreatic resection.

    PubMed

    Park, Jason; Pillarisetty, Venu G; Brennan, Murray F; Jarnagin, William R; D'Angelica, Michael I; Dematteo, Ronald P; G Coit, Daniel; Janakos, Maria; Allen, Peter J

    2010-09-01

    Electronic synoptic operative reports (E-SORs) have replaced dictated reports at many institutions, but whether E-SORs adequately document the components and findings of an operation has received limited study. This study assessed the reliability and completeness of E-SORs for pancreatic surgery developed at our institution. An attending surgeon and surgical fellow prospectively and independently completed an E-SOR after each of 112 major pancreatic resections (78 proximal, 29 distal, and 5 central) over a 10-month period (September 2008 to June 2009). Reliability was assessed by calculating the interobserver agreement between attending physician and fellow reports. Completeness was assessed by comparing E-SORs to a case-matched (surgeon and procedure) historical control of dictated reports, using a 39-item checklist developed through an internal and external query of 13 high-volume pancreatic surgeons. Interobserver agreement between attending and fellow was moderate to very good for individual categorical E-SOR items (kappa = 0.65 to 1.00, p < 0.001 for all items). Compared with dictated reports, E-SORs had significantly higher completeness checklist scores (mean 88.8 +/- 5.4 vs 59.6 +/- 9.2 [maximum possible score, 100], p < 0.01) and were available in patients' electronic records in a significantly shorter interval of time (median 0.5 vs 5.8 days from case end, p < 0.01). The mean time taken to complete E-SORs was 4.0 +/- 1.6 minutes per case. E-SORs for pancreatic surgery are reliable, complete in data collected, and rapidly available, all of which support their clinical implementation. The inherent strengths of E-SORs offer real promise of a new standard for operative reporting and health communication. Copyright 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Engineering Design Handbook: Reliable Military Electronics

    DTIC Science & Technology

    1976-01-15

    p. 30. CBS-Hytron: "I..ow-o::stPower Trall8istors," E1a::Drnic Design, 1 Nov. 1956, p. 24. Chang, C. M.: "An NPN High-Power Fast Germanium Col:e...34Monovibrator Has Fast Recovery Time," Electronics, Dec. 1957, p. 158. Carlson, A W. : "Junction Transistor Counters," EledronicDesign, 1 March 1957, p. 28...Method Makes Fast Pulses in Transistor Circuits," Electronic Design, 28 May 1958, p. 44. Stassior, R. A : "Pulse Applications cf a Diffused-Meltback

  9. [Identification of Lutzomyia spp. (Diptera: Psychodidae) verrucarum group through electron microscopy of its eggs].

    PubMed

    Sierra, D; Vélez, I D; Uribe, S

    2000-01-01

    The value of Colombian phlebotomine eggs for species determination was studied with a scanning electron microscope. The species diversity and medical importance of the verrucarum group were the bases to select Lutzomyia youngi, Lutzomyia evansi, Lutzomyia columbiana and Lutzomyia longiflocosa. The egg surface was poligonal. Lutzomyia youngi, and Lutzomyia columbiana had pentagonal or hexagonal patterns; Lutzomyia evansi elongated polygons and Lutzomyia longiflocosa irregular polygonal sculpturing, frequently rectangular. Egg scanning electron microscopy is reliable to identify species of the verrucarum group.

  10. Tackling reliability and construct validity: the systematic development of a qualitative protocol for skill and incident analysis.

    PubMed

    Savage, Trevor Nicholas; McIntosh, Andrew Stuart

    2017-03-01

    It is important to understand factors contributing to and directly causing sports injuries to improve the effectiveness and safety of sports skills. The characteristics of injury events must be evaluated and described meaningfully and reliably. However, many complex skills cannot be effectively investigated quantitatively because of ethical, technological and validity considerations. Increasingly, qualitative methods are being used to investigate human movement for research purposes, but there are concerns about reliability and measurement bias of such methods. Using the tackle in Rugby union as an example, we outline a systematic approach for developing a skill analysis protocol with a focus on improving objectivity, validity and reliability. Characteristics for analysis were selected using qualitative analysis and biomechanical theoretical models and epidemiological and coaching literature. An expert panel comprising subject matter experts provided feedback and the inter-rater reliability of the protocol was assessed using ten trained raters. The inter-rater reliability results were reviewed by the expert panel and the protocol was revised and assessed in a second inter-rater reliability study. Mean agreement in the second study improved and was comparable (52-90% agreement and ICC between 0.6 and 0.9) with other studies that have reported inter-rater reliability of qualitative analysis of human movement.

  11. Psychometric Inferences from a Meta-Analysis of Reliability and Internal Consistency Coefficients

    ERIC Educational Resources Information Center

    Botella, Juan; Suero, Manuel; Gambara, Hilda

    2010-01-01

    A meta-analysis of the reliability of the scores from a specific test, also called reliability generalization, allows the quantitative synthesis of its properties from a set of studies. It is usually assumed that part of the variation in the reliability coefficients is due to some unknown and implicit mechanism that restricts and biases the…

  12. Reliability of an Automated High-Resolution Manometry Analysis Program across Expert Users, Novice Users, and Speech-Language Pathologists

    ERIC Educational Resources Information Center

    Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.

    2014-01-01

    Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…

  13. A Reliability Generalization Study of the Marlowe-Crowne Social Desirability Scale.

    ERIC Educational Resources Information Center

    Beretvas, S, Natasha; Meyers, Jason L.; Leite, Walter L.

    2002-01-01

    Conducted a reliability generalization study of the Marlowe-Crowne Social Desirability Scale (D. Crowne and D. Marlowe, 1960). Analysis of 93 studies show that the predicted score reliability for male adolescents was 0.53, and reliability for men's responses was lower than for women's. Discusses the need for further analysis of the scale. (SLD)

  14. Reliability of spring interconnects for high channel-count polyimide electrode arrays

    NASA Astrophysics Data System (ADS)

    Khan, Sharif; Ordonez, Juan Sebastian; Stieglitz, Thomas

    2018-05-01

    Active neural implants with a high channel-count need robust and reliable operational assembly for the targeted environment in order to be classified as viable fully implantable systems. The discrete functionality of the electrode array and the implant electronics is vital for intact assembly. A critical interface exists at the interconnection sites between the electrode array and the implant electronics, especially in hybrid assemblies (e.g. retinal implants) where electrodes and electronics are not on the same substrate. Since the interconnects in such assemblies cannot be hermetically sealed, reliable protection against the physiological environment is essential for delivering high insulation resistance and low defusibility of salt ions, which are limited in complexity by current assembly techniques. This work reports on a combination of spring-type interconnects on a polyimide array with silicone rubber gasket insulation for chronically active implantable systems. The spring design of the interconnects on the backend of the electrode array compensates for the uniform thickness of the sandwiched gasket during bonding in assembly and relieves the propagation of extrinsic stresses to the bulk polyimide substrate. The contact resistance of the microflex-bonded spring interconnects with the underlying metallized ceramic test vehicles and insulation through the gasket between adjacent contacts was investigated against the MIL883 standard. The contact and insulation resistances remained stable in the exhausting environmental conditions.

  15. Failure Mechanisms of SAC/Fe-Ni Solder Joints During Thermal Cycling

    NASA Astrophysics Data System (ADS)

    Gao, Li-Yin; Liu, Zhi-Quan; Li, Cai-Fu

    2017-08-01

    Thermal cycling tests have been conducted on Sn-Ag-Cu/Fe- xNi ( x = 73 wt.% or 45 wt.%) and Sn-Ag-Cu/Cu solder joints according to the Joint Electron Device Engineering Council industrial standard to study their interfacial reliability under thermal stress. The interfacial intermetallic compounds formed for solder joints on Cu, Fe-73Ni, and Fe-45Ni were 4.5 μm, 1.7 μm, and 1.4 μm thick, respectively, after 3000 cycles, demonstrating excellent diffusion barrier effect of Fe-Ni under bump metallization (UBM). Also, two deformation modes, viz. solder extrusion and fatigue crack formation, were observed by scanning electron microscopy and three-dimensional x-ray microscopy. Solder extrusion dominated for solder joints on Cu, while fatigue cracks dominated for solder joints on Fe-45Ni and both modes were detected for those on Fe-73Ni. Solder joints on Fe-Ni presented inferior reliability during thermal cycling compared with those on Cu, with characteristic lifetime of 3441 h, 3190 h, and 1247 h for Cu, Fe-73Ni, and Fe-45Ni UBM, respectively. This degradation of the interfacial reliability for solder joints on Fe-Ni is attributed to the mismatch in coefficient of thermal expansion (CTE) at interconnection level. The CTE mismatch at microstructure level was also analyzed by electron backscatter diffraction for clearer identification of recrystallization-related deformation mechanisms.

  16. A quantitative thermal and thermomechanical analysis for design optimization and robustness assessment of microassembled high power Yb:CaF2 thin-disk Laser

    NASA Astrophysics Data System (ADS)

    Joly, S.; Lemesre, M.-A.; Levrier, B.; Lyszyk, C.; Plano, B.; Courjaud, A.; Taira, T.; Bechou, L.

    2018-09-01

    While considerable effort in the field of high power laser research has been dedicated to evolving thin-disk Lasers into the kilowatt range, thermal and residual stress management remain a critical issue and need to be addressed. In this paper, a quantitative thermal and thermomechanical analysis is presented for design optimization and robustness of high power diode pumped thin-disk ytterbium Lasers based on thermal and thermomechanical Finite Element Method (FEM) simulations. In particular, Yb:CaF2 Lasers are examined with respect to the design and selection of the bonding interface material. Results propose the use of a metallic Au80Sn20 hard solder of greater than 20 μm thickness as a superior solution to adhesive bonding for the prevention of Laser crystal failure under high optical pumping power while maintaining sufficient resistance to mechanical strain. Thermal IR characterizations under "safe" CW pumping power validate our predicted FEM Multiphysics models. Finally, an essentially void-free Au80Sn20 soldering process has been demonstrated for the mounting of Yb:CaF2 crystals onto a CuW heat sink. He currently acts as a Full Professor in electronics and physics at the University of Bordeaux. His research field addresses characterization, physical and failure mechanisms modeling and methods for reliability prediction of optoelectronic/photonic micro and nano-assemblied devices (LEDs, laser diodes, fiber laser, optical amplifier, photodetectors, fibered optical module…) for different applications (telecommunications, medical, space...). Research interests focus on Design for Reliability at the early stage of the development of the device including design, fabrication, characterization and aging effects on packaged optoelectronic materials and functions which involves the exploration of the physics of the light-matter interactions as well as the understanding degradation processes. Since 2010 is currently the manager of the "Reliability Assessment of Micro and Nano-assemblied Devices" Research Group (EDMiNA) at IMS Laboratory. He is the author or co-author of more than 180 regular papers and international conferences. He has also chaired different sessions in international conferences and acts as a reviewer of peer-reviewed journals from Elsevier (Microelectronics Reliab., Optics and Laser Technology…), IOP (Optics Letters), IEEE (Photonics Technology Letters, Devices and Materials Reliability, Electron Devices…). He has managed over 20 PhDs grants and post-docs addressing projects focusing both on fundamental aspects as well as applied research with national and European industrial partnerships with over 5M€ of funding. He is involved in several French and European committees acting as reviewer expert for National Research Agency (ANR) and CATRENE/EURIPIDES programs. Since March 2016, he is appointed Visiting Professor at the French-Canadian Joint Lab LN2 - University of Sherbrooke (Qc, Canada) working on packaging and design for reliability of devices and systems for photonic applications.

  17. Multiconfiguration calculations of electronic isotope shift factors in Al i

    NASA Astrophysics Data System (ADS)

    Filippin, Livio; Beerwerth, Randolf; Ekman, Jörgen; Fritzsche, Stephan; Godefroid, Michel; Jönsson, Per

    2016-12-01

    The present work reports results from systematic multiconfiguration Dirac-Hartree-Fock calculations of electronic isotope shift factors for a set of transitions between low-lying levels of neutral aluminium. These electronic quantities together with observed isotope shifts between different pairs of isotopes provide the changes in mean-square charge radii of the atomic nuclei. Two computational approaches are adopted for the estimation of the mass- and field-shift factors. Within these approaches, different models for electron correlation are explored in a systematic way to determine a reliable computational strategy and to estimate theoretical error bars of the isotope shift factors.

  18. Visual and x-ray inspection characteristics of eutectic and lead free assemblies

    NASA Technical Reports Server (NTRS)

    Ghaffarian, R.

    2003-01-01

    For high reliability applications, visual inspection has been the key technique for most conventional electronic package assemblies. Now, the use of x-ray technique has become an additional inspection requirement for quality control and detection of unique defects due to manufacturing of advanced electronic array packages such as ball grid array (BGAs) and chip scale packages (CSPs).

  19. [Test of thermal deformation for electronic devices of high thermal reliability].

    PubMed

    Li, Hai-yuan; Li, Bao-ming

    2002-06-01

    Thermal deformation can be caused by high partial heat flux and greatly reduce thermal reliability of electronic devices. In this paper, an attempt is made to measure the thermal deformation of high power electronic devices under working condition using laser holographic interferometry with double exposure. Laser holographic interferometry is an untouched measurement with measurement precision up to micron dimension. The electronic device chosen for measurement is a type of solid state relay which is used for ignition of rockets. The output circuit of the solid state relay is made up of a MOSFET chip and the power density of the chip can reach high value. In particular situations thermal deformation and stress may significantly influence working performance of the solid state relay. The bulk deformation of the chip and its mount is estimated by number of interferential stripes on chip surface. While thermal stress and deformation can be estimated by curvature of interferential stripes on chip surface. Experimental results indicate that there are more interferential stripes on chip surface and greater flexural degree of stripes under high power. Therefore, these results reflect large out-of-plain displacement and deformed size of the chip with the increase of load current.

  20. Herpes zoster surveillance using electronic databases in the Valencian Community (Spain)

    PubMed Central

    2013-01-01

    Background Epidemiologic data of Herpes Zoster (HZ) disease in Spain are scarce. The objective of this study was to assess the epidemiology of HZ in the Valencian Community (Spain), using outpatient and hospital electronic health databases. Methods Data from 2007 to 2010 was collected from computerized health databases of a population of around 5 million inhabitants. Diagnoses were recorded by physicians using the International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM). A sample of medical records under different criteria was reviewed by a general practitioner, to assess the reliability of codification. Results The average annual incidence of HZ was 4.60 per 1000 persons-year (PY) for all ages (95% CI: 4.57-4.63), is more frequent in women [5.32/1000PY (95% CI: 5.28-5.37)] and is strongly age-related, with a peak incidence at 70-79 years. A total of 7.16/1000 cases of HZ required hospitalization. Conclusions Electronic health database used in the Valencian Community is a reliable electronic surveillance tool for HZ disease and will be useful to define trends in disease burden before and after HZ vaccine introduction. PMID:24094135

Top