Science.gov

Sample records for electrospray characteristic curves

  1. Characteristic Curves.

    ERIC Educational Resources Information Center

    Walkiewicz, Thomas A.; Kirk, James R.

    1994-01-01

    Describes an experiment designed to help students gain a better understanding of the characteristics of various electronic components by incorporating a dual-trace oscilloscope in the X-Y mode in addition to direct observations of phase shifts of various signals into a laboratory exercise. (ZWH)

  2. Effect of pressure on electrospray characteristics

    SciTech Connect

    Marginean, Ioan; Page, Jason S.; Kelly, Ryan T.; Tang, Keqi; Smith, Richard D.

    2009-11-02

    An experimental study of sub-ambient pressure electrosprays is reported. The pressure domain that affords stable electrospray operation appears to be limited by the vapor pressure of the liquid. The voltage driving the electrospray is shown to have a logarithmic dependence on the pressure. This scaling amends the relationship currently in use to calculate the electric field at the tip of the meniscus of an electrified liquid

  3. The Characteristic Curves of Water

    NASA Astrophysics Data System (ADS)

    Neumaier, Arnold; Deiters, Ulrich K.

    2016-09-01

    In 1960, E. H. Brown defined a set of characteristic curves (also known as ideal curves) of pure fluids, along which some thermodynamic properties match those of an ideal gas. These curves are used for testing the extrapolation behaviour of equations of state. This work is revisited, and an elegant representation of the first-order characteristic curves as level curves of a master function is proposed. It is shown that Brown's postulate—that these curves are unique and dome-shaped in a double-logarithmic p, T representation—may fail for fluids exhibiting a density anomaly. A careful study of the Amagat curve (Joule inversion curve) generated from the IAPWS-95 reference equation of state for water reveals the existence of an additional branch.

  4. The stability of Y(Q) characteristic curve

    NASA Astrophysics Data System (ADS)

    Pochylý, F.; Haluza, M.; Klas, R.

    2010-08-01

    The contribution is aimed on the analysis of Y(Q) characteristic of centrifugal pump. The main attention is concentrated on the impeller of high specific speed, especially on the diagonal pumps. It is derived, that stability of Y(Q) curve depends on the dissipative function. The analysis concludes that very important is the design of the interior of spiral case and distributor to achieve a stable Y(Q) characteristic curve.

  5. Continuous columns for determining moisture characteristic curves of soilless substrates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Sound water management is essential for effectively producing nursery crops. Understanding substrate water availability is a critical component to managing irrigation properly. The objective of this paper is to report a method for generating moisture characteristic curves of soilless substrate tha...

  6. Receiver operating characteristic curve generalization for non-monotone relationships.

    PubMed

    Martínez-Camblor, Pablo; Corral, Norberto; Rey, Corsino; Pascual, Julio; Cernuda-Morollón, Eva

    2017-02-01

    The receiver operating characteristic curve is a popular graphical method frequently used in order to study the diagnostic capacity of continuous markers. It represents in a plot true-positive rates against the false-positive ones. Both the practical and theoretical aspects of the receiver operating characteristic curve have been extensively studied. Conventionally, it is assumed that the considered marker has a monotone relationship with the studied characteristic; i.e., the upper (lower) values of the (bio)marker are associated with a higher probability of a positive result. However, there exist real situations where both the lower and the upper values of the marker are associated with higher probability of a positive result. We propose a receiver operating characteristic curve generalization, [Formula: see text], useful in this context. All pairs of possible cut-off points, one for the lower and another one for the upper marker values, are taken into account and the best of them are selected. The natural empirical estimator for the [Formula: see text] curve is considered and its uniform consistency and asymptotic distribution are derived. Finally, two real-world applications are studied.

  7. Electrospray device

    NASA Technical Reports Server (NTRS)

    Demmons, Nathaniel (Inventor); Martin, Roy (Inventor); Hruby, Vladimir (Inventor); Roy, Thomas (Inventor); Spence, Douglas (Inventor); Ehrbar, Eric (Inventor); Zwahlen, Jurg (Inventor)

    2011-01-01

    An electrospray device includes an electrospray emitter adapted to receive electrospray fluid; an extractor plate spaced from the electrospray emitter and having at least one aperture; and a power supply for applying a first voltage between the extractor plate and emitter for generating at least one Taylor cone emission through the aperture to create an electrospray plume from the electrospray fluid, the extractor plate as well as accelerator and shaping plates may include a porous, conductive medium for transporting and storing excess, accumulated electrospray fluid away from the aperture.

  8. Characteristic coloring curve for white bread during baking.

    PubMed

    Onishi, Masanobu; Inoue, Michiko; Araki, Tetsuya; Iwabuchi, Hisakatsu; Sagara, Yasuyuki

    2011-01-01

    The effect of heating conditions on the crust color formation was investigated during the baking of white bread. The surface temperatures were monitored with thermocouples attached to the inside surface of the loaf pan cover. The trace of the surface color in the L(*)a(*)b(*) color coordinate system is defined as the characteristic coloring curve. The overall baking process was classified into the following four stages based on the characteristic coloring curve: i) pre-heating (surface temperature < 110 °C), ii) Maillard reaction (110-150 °C), iii) caramelization (150-200 °C), and iv) over-baking (surface temperature>200 °C). A linear relationship was observed between the L(*) decrease and the increase in weight loss of a sample at each oven air temperature. The L(*) value appeared to be suitable as an indicator to control the surface color by baking conditions.

  9. 7 CFR 42.142 - Curve for obtaining Operating Characteristic (OC) curve information for skip lot sampling and...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... CONDITION OF FOOD CONTAINERS Miscellaneous § 42.142 Curve for obtaining Operating Characteristic (OC)...

  10. 7 CFR 42.142 - Curve for obtaining Operating Characteristic (OC) curve information for skip lot sampling and...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... CONDITION OF FOOD CONTAINERS Miscellaneous § 42.142 Curve for obtaining Operating Characteristic (OC)...

  11. Therapy operating characteristic curves: tools for precision chemotherapy.

    PubMed

    Barrett, Harrison H; Alberts, David S; Woolfenden, James M; Caucci, Luca; Hoppin, John W

    2016-04-01

    The therapy operating characteristic (TOC) curve, developed in the context of radiation therapy, is a plot of the probability of tumor control versus the probability of normal-tissue complications as the overall radiation dose level is varied, e.g., by varying the beam current in external-beam radiotherapy or the total injected activity in radionuclide therapy. This paper shows how TOC can be applied to chemotherapy with the administered drug dosage as the variable. The area under a TOC curve (AUTOC) can be used as a figure of merit for therapeutic efficacy, analogous to the area under an ROC curve (AUROC), which is a figure of merit for diagnostic efficacy. In radiation therapy, AUTOC can be computed for a single patient by using image data along with radiobiological models for tumor response and adverse side effects. The mathematical analogy between response of observers to images and the response of tumors to distributions of a chemotherapy drug is exploited to obtain linear discriminant functions from which AUTOC can be calculated. Methods for using mathematical models of drug delivery and tumor response with imaging data to estimate patient-specific parameters that are needed for calculation of AUTOC are outlined. The implications of this viewpoint for clinical trials are discussed.

  12. Effects of rail dynamics and friction characteristics on curve squeal

    NASA Astrophysics Data System (ADS)

    Ding, B.; Squicciarini, G.; Thompson, D. J.

    2016-09-01

    Curve squeal in railway vehicles is an instability mechanism that arises in tight curves under certain running and environmental conditions. In developing a model the most important elements are the characterisation of friction coupled with an accurate representation of the structural dynamics of the wheel. However, the role played by the dynamics of the rail is not fully understood and it is unclear whether this should be included in a model or whether it can be safely neglected. This paper makes use of previously developed time domain and frequency domain curve squeal models to assess whether the presence of the rail and the falling characteristics of the friction force can modify the instability mechanisms and the final response. For this purpose, the time-domain model has been updated to include the rail dynamics in terms of its state space representation in various directions. Frequency domain and time domain analyses results show that falling friction is not the only reason for squeal and rail dynamics can play an important role, especially under constant friction conditions.

  13. Exploring Alternative Characteristic Curve Approaches to Linking Parameter Estimates from the Generalized Partial Credit Model.

    ERIC Educational Resources Information Center

    Roberts, James S.; Bao, Han; Huang, Chun-Wei; Gagne, Phill

    Characteristic curve approaches for linking parameters from the generalized partial credit model were examined for cases in which common (anchor) items are calibrated separately in two groups. Three of these approaches are simple extensions of the test characteristic curve (TCC), item characteristic curve (ICC), and operating characteristic curve…

  14. Improved Suter-transformation for complete characteristic curves of pump-turbine

    NASA Astrophysics Data System (ADS)

    Zheng, X. B.; Guo, P. C.; Tong, H. Z.; Luo, X. Q.

    2012-11-01

    The complete characteristic curve of the pump turbine show "s" characteristic in the anti-pump and pump working-condition. The multi-numerical values of unit discharge and unit moment the curve caused by crossover and overlap phenomena of the curve may bring inconvenience for transition process analysis. In this paper, complete characteristic curves of the pump turbine were dealt with using improved Suter curve transformation method. A surface fitting were carried out for transformed WH curve. Therefore, a three-dimensioned surface was achieved. The transition process of load shedding was analyzed using the curve above-mentioned. The results show that the method used in the paper can eliminates the uneven distribution, crossover, overlapping and multi-value characteristic, thus providing convenience for the transition process analysis of pump-turbine.

  15. Fitting Item Characteristic Curves with Spline Functions. [Program Statistics Research Technical Report Series].

    ERIC Educational Resources Information Center

    Winsberg, Suzanne; And Others

    In most item response theory models a particular mathematical form is assumed for all item characteristic curves, e.g., a logistic function. It could be desirable, however, to estimate the shape of the item characteristic curves without prior restrictive assumptions about its mathematical form. We have developed a practical method of estimating…

  16. Modelling Soil Water Characteristic Curves for the Investigation of Hydrophobicity

    NASA Astrophysics Data System (ADS)

    Hallin, Ingrid; Matthews, Peter; Laudone, Maurizio; Van Keulen, Geertje; Doerr, Stefan; Francis, Lewis; Dudley, Ed; Gazze, Andrea; Quinn, Gerry; Whalley, Richard; Ashton, Rhys

    2016-04-01

    Soil hydrophobicity presents a major challenge for the future, as it reduces both plant-available water and irrigation efficiency, and can increase flooding hazards and erosion. A collaborative research project has been set up in the UK to study hydrophobicity over a wide range of length scales. At core scale, we are investigating the wetting behaviour of water repellent soils in order to model percolation through hydrophobic pore spaces. To that end, water retention measurements were carried out on both wettable and forcibly-wetted water-repellent soils collected from three locations in England and Wales. The data were then fitted with both the commonly used Van Genuchten model and an alternative model from PoreXpert, a software program that analyses and models porous materials. The Van Genuchten model fits a curve to the data using parameters related to air entry suction, irreducible water content and pore size distribution. By contrast, PoreXpert uses a Boltzmann-annealed simplex to find a best-fit curve based on parameters directly related to the void structure of the soil: the size of the voids, the shape of the void size distribution, and how the voids are connected to each other. Both Van Genuchten and PoreXpert fit the experimental data well, but where Van Genuchten forces an S-shaped curve that can mask small variations, PoreXpert gives a closer fit of no pre-defined shape that captures subtle differences between data points. This allows us to calculate differences in the effective pore and throat size distributions, and provides a mechanistic framework from which to model additional hydrologic behaviour in water repellent soil. Simulations of capillary induced wetting based on these mechanistic postulates are then compared to wicking experiments at the core scale, which can then be upscaled and applied to other soils.

  17. Influence of horizontally curved roadway section characteristics on motorcycle-to-barrier crash frequency.

    PubMed

    Gabauer, Douglas J; Li, Xiaolong

    2015-04-01

    The purpose of this study was to investigate motorcycle-to-barrier crash frequency on horizontally curved roadway sections in Washington State using police-reported crash data linked with roadway data and augmented with barrier presence information. Data included 4915 horizontal curved roadway sections with 252 of these sections experiencing 329 motorcycle-to-barrier crashes between 2002 and 2011. Negative binomial regression was used to predict motorcycle-to-barrier crash frequency using horizontal curvature and other roadway characteristics. Based on the model results, the strongest predictor of crash frequency was found to be curve radius. This supports a motorcycle-to-barrier crash countermeasure placement criterion based, at the very least, on horizontal curve radius. With respect to the existing horizontal curve criterion of 820 feet or less, curves meeting this criterion were found to increase motorcycle-to-barrier crash frequency rate by a factor of 10 compared to curves not meeting this criterion. Other statistically significant predictors were curve length, traffic volume and the location of adjacent curves. Assuming curves of identical radius, the model results suggest that longer curves, those with higher traffic volume, and those that have no adjacent curved sections within 300 feet of either curve end would likely be better candidates for a motorcycle-to-barrier crash countermeasure.

  18. 7 CFR 43.105 - Operating characteristics (OC) curves.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 43.105 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.105 Operating characteristics...

  19. 7 CFR 43.105 - Operating characteristics (OC) curves.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 43.105 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.105 Operating characteristics...

  20. 7 CFR 43.105 - Operating characteristics (OC) curves.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 43.105 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.105 Operating characteristics...

  1. 7 CFR 43.105 - Operating characteristics (OC) curves.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 43.105 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.105 Operating characteristics...

  2. 7 CFR 43.105 - Operating characteristics (OC) curves.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 43.105 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.105 Operating characteristics...

  3. Receiver operating characteristic-curve limits of detection

    NASA Astrophysics Data System (ADS)

    Wysoczanski, Artur; Voigtman, Edward

    2014-10-01

    Using a simple UV LED-excited ruby fluorescence measurement system, we demonstrate that it is easily possible to obtain unbiased detection limits, despite the system deliberately having non-linear response function and non-Gaussian noise. Even when the noise precision model is heteroscedastic, but otherwise only roughly linear, the receiver operating characteristic (ROC) method readily yields results that are in accordance with a priori canonical specifications of false positives and false negatives at the detection limit. The present work demonstrates that obtaining unbiased detection limits is not abstruse and need not be mathematically complicated. Rather, detection limits continue to serve a useful purpose as part of the characterization of chemical measurement systems.

  4. Atlas of Light Curves of Faint Mira-Type Stars. Statistical Relations Between the Characteristics of Smoothed Phase Light Curves

    NASA Astrophysics Data System (ADS)

    Kudashkina, L. S.; Andronov, I. L.

    2010-12-01

    We propose a set of the photometric parameters which could be useful for the classiffication of the pulsating Mira-type stars and related objects and determination of the EAGB and TPAGB stages of the stellar evolution. To solve this problem, the light curves of faint Mira- type stars and of the semi-regular variable V411 Sct were approximated using the program FDCN, which computes a trigonometric polynomial of a statistically optimal degree (I.L.Andronov, 1994, 2003). The at las of statistically optimal fits of the phase curves of 34 long-period is presented, based on digitized data from the scanned "Atlas" by P. Maffei and G.Tosti (http://astro.fisica.unipg.it/atlasmaffei/main.htm). Some statistical relations between the parameters of the trigonometrical polynomial approximation of the phase curve are analyzed. for an additional criterion of detailed classiffication of long-perodic variables, we used various parameters, e.g. "period", "amplitude", "asymmetry", "slope of the ascending branch", "characteristic time of brightening by 1m": Discussion of the results is presented.

  5. Analysis of driver's characteristics on a curved road in a lattice model

    NASA Astrophysics Data System (ADS)

    Kaur, Ramanpreet; Sharma, Sapna

    2017-04-01

    The present paper investigates the effect of driver's behavior on the curved road via lattice hydrodynamic approach. The basic model for straight road is extended for the curved road and the characteristics of driver's behavior is incorporated in the lattice model. The extended model is investigated theoretically by the means of linear stability analysis and the effect of curved road and intensity of influence of driver's behavior on the traffic flow stability is examined. Through nonlinear stability analysis, the modified Korteweg-de Vries (MKdV) equation near the critical point is derived to describe the evolution properties of traffic density waves by applying the reductive perturbation method. Furthermore, the numerical simulation is carried out to validate the theoretical results which indicates that the curved road has a negative influence on the stability of the traffic flow. It is also seen that the traffic jam on a curved road can be suppressed efficiently via taking into account aggressive drivers.

  6. Logistic Positive Exponent Family of Models: Virtue of Asymmetric Item Characteristic Curves.

    ERIC Educational Resources Information Center

    Samejima, Fumiko

    2000-01-01

    Discusses whether the tradition of accepting point-symmetric item characteristic curves is justified by uncovering the inconsistent relationship between the difficulties of items and the order of maximum likelihood estimates of ability. In this context, proposes a family of models, called the logistic positive exponent family, that provides…

  7. On the Use of Nonparametric Item Characteristic Curve Estimation Techniques for Checking Parametric Model Fit

    ERIC Educational Resources Information Center

    Lee, Young-Sun; Wollack, James A.; Douglas, Jeffrey

    2009-01-01

    The purpose of this study was to assess the model fit of a 2PL through comparison with the nonparametric item characteristic curve (ICC) estimation procedures. Results indicate that three nonparametric procedures implemented produced ICCs that are similar to that of the 2PL for items simulated to fit the 2PL. However for misfitting items,…

  8. A Comparison of Methods for Nonparametric Estimation of Item Characteristic Curves for Binary Items

    ERIC Educational Resources Information Center

    Lee, Young-Sun

    2007-01-01

    This study compares the performance of three nonparametric item characteristic curve (ICC) estimation procedures: isotonic regression, smoothed isotonic regression, and kernel smoothing. Smoothed isotonic regression, employed along with an appropriate kernel function, provides better estimates and also satisfies the assumption of strict…

  9. Evaluation of a computer program used to estimate water characteristic curve

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The soil water characteristic curve, h(theta), can be used to estimate a variety of parameters in unsaturated soils. One practical application of h(theta) is its use by DRAINMOD, a drainage model that has been widely used in shallow water table regions, to determine the water table depth–drainage v...

  10. Effects on Scale Linking of Different Definitions of Criterion Functions for the IRT Characteristic Curve Methods

    ERIC Educational Resources Information Center

    Kim, Seonghoon; Kolen, Michael J.

    2007-01-01

    Under item response theory, the characteristic curve methods (Haebara and Stocking-Lord methods) are used to link two ability scales from separate calibrations. The linking methods use their respective criterion functions that can be defined differently according to the symmetry- and distribution-related schemes. The symmetry-related scheme…

  11. Use of a submersible pressure outflow cell for determination of moisture characteristic curves on rock core

    SciTech Connect

    Flint, L.E.; Flint, A.L.

    1993-06-01

    A simple device for developing moisture characteristic data curves, the submersible pressure outflow cell, was modified for application to rock core at matric potentials of 0 to -0.5 megapascals (MPa) and possibly to -1.0 Mpa. An automated system was developed to continuously and simultaneously collect data from many cells, obtain sorption and desorption characteristic curves to provide hysteretic information, and data from multi-step outflow experiments. The latter can be used to estimate unsaturated hydraulic conductivity. The system has resolved many of the problems inherent in standard measurement techniques. Model simulation of imbibition using the hysteretic data collected are in close agreement with laboratory measurements of imbibition, data collected are in close agreement with laboratory measurements of imbibition, suggesting the moisture characteristic data correctly describes the core properties.19 refs., 4 figs.

  12. Experimental study of characteristic curves of centrifugal pumps working as turbines in different specific speeds

    SciTech Connect

    Derakhshan, Shahram; Nourbakhsh, Ahmad

    2008-01-15

    Pump manufacturers do not normally provide the characteristic curves of their pumps working as turbines. Therefore, establishing a correlation between the performances of direct (pump) and reverse (turbine) modes is essential in selecting the proper machine. In this paper, several centrifugal pumps (N{sub s} < 60 (m, m{sup 3}/s)) were tested as turbines. Using experimental data, some relations were derived to predict the best efficiency point of a pump working as a turbine, based on pump hydraulic characteristics. Validity of the presented method was shown using some referenced experimental data. Two equations were presented to estimate the complete characteristic curves of centrifugal pumps as turbines based on their best efficiency point. Deviations of suggested method from experimental data were considered and discussed. Finally, a procedure was presented for selecting a suitable pump to work as a turbine in a small hydro-site. (author)

  13. Modeling geologic storage of carbon dioxide: Comparison ofnon-hysteretic and hysteretic characteristic curves

    SciTech Connect

    Doughty, Christine

    2006-07-17

    Numerical models of geologic storage of carbon dioxide (CO2)in brine-bearing formations use characteristic curves to represent theinteractions of non-wetting-phase CO2 and wetting-phase brine. When aproblem includes both injection of CO2 (a drainage process) and itssubsequent post-injection evolution (a combination of drainage andwetting), hysteretic characteristic curves are required to correctlycapture the behavior of the CO2 plume. In the hysteretic formulation,capillary pressure and relative permeability depend not only on thecurrent grid-block saturation, but also on the history of the saturationin the grid block. For a problem that involves only drainage or onlywetting, a non-hysteretic formulation, in which capillary pressure andrelative permeability depend only on the current value of the grid-blocksaturation, is adequate. For the hysteretic formulation to be robustcomputationally, care must be taken to ensure the differentiability ofthe characteristic curves both within and beyond the turning-pointsaturations where transitions between branches of the curves occur. Twoexample problems involving geologic CO2 storage are simulated withTOUGH2, a multiphase, multicomponent code for flow and transport codethrough geological media. Both non-hysteretic and hysteretic formulationsare used, to illustrate the applicability and limitations ofnon-hysteretic methods.The first application considers leakage of CO2from the storage formation to the ground surface, while the secondexamines the role of heterogeneity within the storageformation.

  14. Analysis of Characteristics of Light Curve Profiles of the Flares Erupted from Sun-like Stars

    NASA Astrophysics Data System (ADS)

    Duo, Yun; Hua-ning, Wang; Han, He

    2017-01-01

    Solar flares belong to a kind of eruptive phenomena caused by the sudden release of magnetic energy nearby sunspots. It is found that similar flares occurred as well in many Sun-like stars (called as Sun-like star flares). From the data acquired by the Kepler space telescope the SC (Short Cadence) data are mainly selected to make analysis, in order to find the characteristic parameters of light curve profiles of the flares erupted from Sun-like stars for a statistical study, and to summarize the activity features of these stellar flares. The analyzed results show that the light curve profiles and characteristic timescales of the flares of Sun-like stars are quite similar to those of solar flares, which may indicate the same physical mechanism for these two kinds of flares.

  15. Consequence analysis to determine the damage to humans from vapour cloud explosions using characteristic curves.

    PubMed

    Alonso, Fernando Díaz; Ferradás, Enrique González; Sánchez, Teresa de Jesús Jiménez; Aznar, Agustín Miñana; Gimeno, José Ruiz; Alonso, Jesús Martínez

    2008-01-15

    The aim of this paper is to provide a methodology to facilitate consequence analysis for vapour cloud explosions (VCE). Firstly, the main PROBIT equations to evaluate direct damage on humans from those accidents (eardrum rupture, death due to skull fracture, death due to whole body impact and lung damage) are discussed and the most suitable ones are selected. Secondly, a new methodology is developed to relate characteristic overpressure-impulse-distance curves for VCE, obtained in a previous paper (F. Diaz Alonso et al., Characteristic overpressure-impulse-distance curves for vapour cloud explosions using the TNO Multi-Energy model, J. Hazard. Mater. A137 (2006) 734-741) with the selected PROBIT equations. This methodology allows the determination of damage as a function of distance to the accident's origin in only one step, using explosion energy and VCE Multi-Energy charge strength as input parameters.

  16. The Effect of Compaction on Moisture Characteristic Curves of Compactible Soils Measured in a UFAT

    NASA Astrophysics Data System (ADS)

    Baker, K. E.; Poloski, A. P.; Owen, A. T.; Lindenmeier, C. W.; Thompson, D. N.

    2001-12-01

    The objective of this study was to develop and test methods to allow the use of the Unsaturated Flow Apparatus (UFAT) for characterization of hydraulic properties of compactable soils often encountered in vadose zone environments. Use of the UFA in this application is limited by compaction of the soil under the applied centrifugal force. The UFA significantly reduces the time required to reach moisture equilibrium by applying driving forces thousands of times greater than natural driving forces for unsaturated flow through sample cores. However, the centrifugal force will also cause some soils to compress in the instrument, significantly changing the macropore volume distribution and thus the moisture characteristic curve. Moisture characteristic curves of undisturbed soil cores were measured both by traditional methods and in the UFA. Changes in pore volume distributions were estimated using X-ray micro-focus tomography (XMT) both before and after adjustment of the moisture content. Using a mathematical model, compaction of the pores at each UFA rotational speed can be accounted for and an original uncompacted macropore volume distribution can be estimated. This uncompacted macropore volume distribution can then be used to predict the moisture characteristic curve of the original soil, greatly shortening the time necessary to complete these measurements.

  17. 7 CFR 42.142 - Curve for obtaining Operating Characteristic (OC) curve information for skip lot sampling and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) curve information for skip lot sampling and inspection. 42.142 Section 42.142 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS...

  18. Linking Parameters Estimated with the Generalized Graded Unfolding Model: A Comparison of the Accuracy of Characteristic Curve Methods

    ERIC Educational Resources Information Center

    Anderson Koenig, Judith; Roberts, James S.

    2007-01-01

    Methods for linking item response theory (IRT) parameters are developed for attitude questionnaire responses calibrated with the generalized graded unfolding model (GGUM). One class of IRT linking methods derives the linking coefficients by comparing characteristic curves, and three of these methods---test characteristic curve (TCC), item…

  19. THE LICK AGN MONITORING PROJECT: PHOTOMETRIC LIGHT CURVES AND OPTICAL VARIABILITY CHARACTERISTICS

    SciTech Connect

    Walsh, Jonelle L.; Bentz, Misty C.; Barth, Aaron J.; Minezaki, Takeo; Sakata, Yu; Yoshii, Yuzuru; Baliber, Nairn; Bennert, Vardha Nicola; Street, Rachel A.; Treu, Tommaso; Li Weidong; Filippenko, Alexei V.; Stern, Daniel; Brown, Timothy M.; Canalizo, Gabriela; Gates, Elinor L.; Greene, Jenny E.; Malkan, Matthew A.; Woo, Jong-Hak

    2009-11-01

    The Lick AGN Monitoring Project targeted 13 nearby Seyfert 1 galaxies with the intent of measuring the masses of their central black holes using reverberation mapping. The sample includes 12 galaxies selected to have black holes with masses roughly in the range 10{sup 6}-10{sup 7} M {sub sun}, as well as the well-studied active galactic nucleus (AGN) NGC 5548. In conjunction with a spectroscopic monitoring campaign, we obtained broadband B and V images on most nights from 2008 February through 2008 May. The imaging observations were carried out by four telescopes: the 0.76 m Katzman Automatic Imaging Telescope, the 2 m Multicolor Active Galactic Nuclei Monitoring telescope, the Palomar 60 inch (1.5 m) telescope, and the 0.80 m Tenagra II telescope. Having well-sampled light curves over the course of a few months is useful for obtaining the broad-line reverberation lag and black hole mass, and also allows us to examine the characteristics of the continuum variability. In this paper, we discuss the observational methods and the photometric measurements, and present the AGN continuum light curves. We measure various variability characteristics of each of the light curves. We do not detect any evidence for a time lag between the B- and V-band variations, and we do not find significant color variations for the AGNs in our sample.

  20. Performance characteristics of a curved-channel microchannel plate with a curved input face and a plane output face

    NASA Technical Reports Server (NTRS)

    Slater, David C.; Morgan, Jeffrey S.; Timothy, J. Gethyn

    1989-01-01

    The presently performance-evaluated format, in which a high-gain curved-channel microchannel plate (M2MCP) has a spherical concave input face and a plane output face, allows the input face of the MCP (1) to match such curved focal surfaces as that of a Rowland-circle spectrometer mounting, while (2) having a high-resolution plane readout array in proximity focus with the output face. This MCP has been evaluated in a discrete-anode multicathode microchannel array detector system. The saturated modal gain was found to be inversely proportional to the length/diameter ratio of the channels and directly proportional to the applied MCP voltage.

  1. High sensitive translational temperature measurement using characteristic curve of second harmonic signal in wavelength modulation spectroscopy

    NASA Astrophysics Data System (ADS)

    Matsui, Makoto; Yamada, Tohru

    2017-01-01

    A high sensitive measurement system of translational temperature of plasma was developed. In this system, which is based on wavelength modulation spectroscopy, a peak value of second harmonic signal was measured as a function of modulation depth. The translational temperature was estimated by fitting the theoretically calculated curve to the measured characteristic curve. The performance of this system was examined using microwave discharge plasma. As a result of comparison with conventional laser absorption spectroscopy, both results show good agreement in the measurable region of the laser absorption spectroscopy. Next, the measurable limit of this system was investigated by decreasing the target number density. The detectable fractional absorption was as low as 3.7 × 10-5 in which condition the signal to noise ratio was the order of single digit at the averaging number of 40. This value is more than two orders of magnitude lower than that of the laser absorption spectroscopy.

  2. Evaluation of curving characteristics of flexible liquid crystal displays fabricated using polycarbonate substrates

    NASA Astrophysics Data System (ADS)

    Sato, Akihito; Ishinabe, Takahiro; Fujikake, Hideo

    2016-01-01

    The improvement of the contrast ratio of flexible liquid crystal displays (LCDs) fabricated using plastic substrates in a curved state is an important problem to achieve high-quality flexible LCDs. In this study, we evaluated the distributions of in-plane phase retardation and slow axis direction of polycarbonate substrates and the effects of curvature on the electro-optical properties of flexible LCDs. As a result, we clarified that the polycarbonate substrates have high uniformity in the in-plane phase retardation and slow axis direction, and that the change in the phase retardation of the polycarbonate substrate caused by the curvature deformation has a small effect on the electro-optical characteristics of flexible LCDs. We successfully achieved a high contrast ratio of 1042:1 by fabricating the device using polycarbonate substrates. This result indicates that it is possible to realize high-quality images in flexible LCDs fabricated using polycarbonate substrates even in the curved state.

  3. Full receiver operating characteristic curve estimation using two alternative forced choice studies.

    PubMed

    Massanes, Francesc; Brankov, Jovan G

    2016-01-01

    Task-based medical image quality is typically measured by the degree to which a human observer can perform a diagnostic task in a psychophysical human observer study. During a typical study, an observer is asked to provide a numerical score quantifying his confidence as to whether an image contains a diagnostic marker or not. Such scores are then used to measure the observers' diagnostic accuracy, summarized by the receiver operating characteristic (ROC) curve and the area under ROC curve. These types of human studies are difficult to arrange, costly, and time consuming. In addition, human observers involved in this type of study should be experts on the image genre to avoid inconsistent scoring through the lengthy study. In two-alternative forced choice (2AFC) studies, known to be faster, two images are compared simultaneously and a single indicator is given. Unfortunately, the 2AFC approach cannot lead to a full ROC curve or a set of image scores. The aim of this work is to propose a methodology in which multiple rounds of the 2AFC studies are used to re-estimate an image confidence score (a.k.a. rating, ranking) and generate the full ROC curve. In the proposed approach, we treat image confidence score as an unknown rating that needs to be estimated and 2AFC as a two-player match game. To achieve this, we use the ELO rating system, which is used for calculating the relative skill levels of players in competitor-versus-competitor games such as chess. The proposed methodology is not limited to ELO, and other rating methods such as TrueSkill™, Chessmetrics, or Glicko can be also used. The presented results, using simulated data, indicate that a full ROC curve can be recovered using several rounds of 2AFC studies and that the best pairing strategy starts with the first round of pairing abnormal versus normal images (as in the classical 2AFC approach) followed by a number of rounds using random pairing. In addition, the proposed method was tested in a pilot human

  4. Full receiver operating characteristic curve estimation using two alternative forced choice studies

    PubMed Central

    Massanes, Francesc; Brankov, Jovan G.

    2016-01-01

    Abstract. Task-based medical image quality is typically measured by the degree to which a human observer can perform a diagnostic task in a psychophysical human observer study. During a typical study, an observer is asked to provide a numerical score quantifying his confidence as to whether an image contains a diagnostic marker or not. Such scores are then used to measure the observers’ diagnostic accuracy, summarized by the receiver operating characteristic (ROC) curve and the area under ROC curve. These types of human studies are difficult to arrange, costly, and time consuming. In addition, human observers involved in this type of study should be experts on the image genre to avoid inconsistent scoring through the lengthy study. In two-alternative forced choice (2AFC) studies, known to be faster, two images are compared simultaneously and a single indicator is given. Unfortunately, the 2AFC approach cannot lead to a full ROC curve or a set of image scores. The aim of this work is to propose a methodology in which multiple rounds of the 2AFC studies are used to re-estimate an image confidence score (a.k.a. rating, ranking) and generate the full ROC curve. In the proposed approach, we treat image confidence score as an unknown rating that needs to be estimated and 2AFC as a two-player match game. To achieve this, we use the ELO rating system, which is used for calculating the relative skill levels of players in competitor-versus-competitor games such as chess. The proposed methodology is not limited to ELO, and other rating methods such as TrueSkill™, Chessmetrics, or Glicko can be also used. The presented results, using simulated data, indicate that a full ROC curve can be recovered using several rounds of 2AFC studies and that the best pairing strategy starts with the first round of pairing abnormal versus normal images (as in the classical 2AFC approach) followed by a number of rounds using random pairing. In addition, the proposed method was tested in a

  5. Quantification of damage detection schemes using receiver operating characteristic (ROC) curves

    NASA Astrophysics Data System (ADS)

    Trickey, Stephen; Seaver, Mark; Nichols, Jon

    2007-04-01

    In this work we detect damage in a composite to metal bolted joint subject to ambient vibrations and strong temperature fluctuations. Damage to the joint is considered to be a degradation of the connection strength implemented by loosening the bolts. The system is excited with a signal that conforms to the Pierson-Moskowitz distribution for wave height and represents a possible loading this component would be subject to in situ. We show that as the bolts are loosened, increasing amounts of nonlinearity are introduced in the form of impact discontinuities and stick-slip behavior. The presence of the nonlinearity, hence the damage, is detected by drawing comparisons between the response data and surrogate data conforming to the null hypothesis of an undamaged, linear system. Two metrics are used for comparison purposes: nonlinear prediction error and the bicoherence. Results are displayed using Receiver Operating Characteristic (ROC) curves. The ROC curve quantifies the trade-off between false positives (type I errors) and false negatives (type II errors). Type I errors can be expressed as the probability of false alarm and 1 - type II error is the probability of detection. We demonstrate that ROC curves provide a unified quantifiable approach for directly comparing the merits of different detection schemes.

  6. A simple method to estimate the time-dependent receiver operating characteristic curve and the area under the curve with right censored data.

    PubMed

    Li, Liang; Greene, Tom; Hu, Bo

    2016-11-27

    The time-dependent receiver operating characteristic curve is often used to study the diagnostic accuracy of a single continuous biomarker, measured at baseline, on the onset of a disease condition when the disease onset may occur at different times during the follow-up and hence may be right censored. Due to right censoring, the true disease onset status prior to the pre-specified time horizon may be unknown for some patients, which causes difficulty in calculating the time-dependent sensitivity and specificity. We propose to estimate the time-dependent sensitivity and specificity by weighting the censored data by the conditional probability of disease onset prior to the time horizon given the biomarker, the observed time to event, and the censoring indicator, with the weights calculated nonparametrically through a kernel regression on time to event. With this nonparametric weighting adjustment, we derive a novel, closed-form formula to calculate the area under the time-dependent receiver operating characteristic curve. We demonstrate through numerical study and theoretical arguments that the proposed method is insensitive to misspecification of the kernel bandwidth, produces unbiased and efficient estimators of time-dependent sensitivity and specificity, the area under the curve, and other estimands from the receiver operating characteristic curve, and outperforms several other published methods currently implemented in R packages.

  7. Characteristics of dewatering induced drawdown curve under blocking effect of retaining wall in aquifer

    NASA Astrophysics Data System (ADS)

    Wu, Yong-Xia; Shen, Shui-Long; Yuan, Da-Jun

    2016-08-01

    For deep excavation pits that require the pumping of confined groundwater, a combination of a retaining wall and dewatering with large-diameter wells is usually adopted during excavation to improve safety. Since a retaining wall has a much lower hydraulic conductivity than the surrounding material in the aquifer, blocking of seepage to prolong the seepage path of the groundwater outside of the pit is effective. The retaining walls used during excavation dewatering cause hydraulic head drawdown inside the pit much faster than outside the pit. Thus, difference in hydraulic head between inside and outside of the pit increases. To investigate the mechanism of the blocking effect, numerical simulation using the finite difference method (FDM) was conducted to analyze the effects of pumping in the pit. The FDM results show that drawdown varies along the depth of the confined aquifer. The influence factors of drawdown inside and outside the pit include insertion depth of retaining walls, anisotropy of a confined aquifer and screen length of pumping wells. In addition, FDM results also show that the drawdown-time curve can be divided into four stages: in Stage I, drawdown inside the pit is very small and outside the pit it is almost zero; in Stage II, drawdown increases quickly with time; in Stage III, the drawdown curve is parallel to the Cooper-Jacob curve on semi-log axes; and in Stage IV, the drawdown becomes constant. These characteristics of the drawdown curve under the blocking effect of a retaining wall in an aquifer provide a way of estimating hydrogeological parameters according to pumping test results.

  8. Adjusting for covariate effects on classification accuracy using the covariate-adjusted receiver operating characteristic curve.

    PubMed

    Janes, Holly; Pepe, Margaret S

    2009-06-01

    Recent scientific and technological innovations have produced an abundance of potential markers that are being investigated for their use in disease screening and diagnosis. In evaluating these markers, it is often necessary to account for covariates associated with the marker of interest. Covariates may include subject characteristics, expertise of the test operator, test procedures or aspects of specimen handling. In this paper, we propose the covariate-adjusted receiver operating characteristic curve, a measure of covariate-adjusted classification accuracy. Nonparametric and semiparametric estimators are proposed, asymptotic distribution theory is provided and finite sample performance is investigated. For illustration we characterize the age-adjusted discriminatory accuracy of prostate-specific antigen as a biomarker for prostate cancer.

  9. Assessing the Classification Accuracy of Early Numeracy Curriculum-Based Measures Using Receiver Operating Characteristic Curve Analysis

    ERIC Educational Resources Information Center

    Laracy, Seth D.; Hojnoski, Robin L.; Dever, Bridget V.

    2016-01-01

    Receiver operating characteristic curve (ROC) analysis was used to investigate the ability of early numeracy curriculum-based measures (EN-CBM) administered in preschool to predict performance below the 25th and 40th percentiles on a quantity discrimination measure in kindergarten. Areas under the curve derived from a sample of 279 students ranged…

  10. Locating Groundwater Pollution Source using Breakthrough Curve Characteristics and Artificial Neural Networks

    NASA Astrophysics Data System (ADS)

    Kumar, J.; Jain, A.; Srivastava, R.

    2005-12-01

    The identification of pollution sources in aquifers is an important area of research not only for the hydrologists but also for the local and Federal agencies and defense organizations. Once the data in terms of pollutant concentration measurements at observation wells become known, it is important to identify the polluting industry in order to implement punitive or remedial measures. Traditionally, hydrologists have relied on the conceptual methods for the identification of groundwater pollution sources. The problem of identification of groundwater pollution sources using the conceptual methods requires a thorough understanding of the groundwater flow and contaminant transport processes and inverse modeling procedures that are highly complex and difficult to implement. Recently, the soft computing techniques, such as artificial neural networks (ANNs) and genetic algorithms, have provided an attractive and easy to implement alternative to solve complex problems efficiently. Some researchers have used ANNs for the identification of pollution sources in aquifers. A major problem with most previous studies using ANNs has been the large size of the neural networks that are needed to model the inverse problem. The breakthrough curves at an observation well may consist of hundreds of concentration measurements, and presenting all of them to the input layer of an ANN not only results in humongous networks but also requires large amount of training and testing data sets to develop the ANN models. This paper presents the results of a study aimed at using certain characteristics of the breakthrough curves and ANNs for determining the distance of the pollution source from a given observation well. Two different neural network models are developed that differ in the manner of characterizing the breakthrough curves. The first ANN model uses five parameters, similar to the synthetic unit hydrograph parameters, to characterize the breakthrough curves. The five parameters employed

  11. A Method to Recover Useful Geothermal-Reservoir Parameters from Production Characteristic Curves (1) Steam Reservoirs

    SciTech Connect

    Iglesias, E.; Arellano, V.; Garfias, A.; Miranda, C.; Hernandez, J.; Gonzalez, J.

    1983-12-15

    In this paper we develop and demonstrate a method to estimate the reservoir pressure and a productivity index for vertical steam wells, from its production characteristic (also called output) curves. In addition, the method allows to estimate the radius of influence of the well, provided that a value of the reservoir transmisivity is available. The basic structure of the present method is: first, the measured well head mass flowrates and pressures are transformed to downhole conditions by means of a numerical simulator; then, the computed downhole variables are fitted to a simple radial model that predicts the sandface flowrate in terms of the flowing pressure. For demonstration, the method was applied to several steam wells from the Los Azufres Geothermal field. We found excellent agreement of the model with this ample set of field data. As a bonus, the processed data allowed several inferences about the steam producing zone of the reservoir: that the wells considered produce from relatively isolated pockets of steam, which are probably fed by near-by inmobile water; and that these feed zones are in poor hydraulic communication with the field surface waters. our method are that it provides a way to retrieve important reservoir information from usually available production characteristic curves, and that the method works from easily and accurately taken wellhead measurements.

  12. Therapy Operating Characteristic (TOC) Curves and their Application to the Evaluation of Segmentation Algorithms.

    PubMed

    Barrett, Harrison H; Wilson, Donald W; Kupinski, Matthew A; Aguwa, Kasarachi; Ewell, Lars; Hunter, Robert; Müller, Stefan

    2010-01-01

    This paper presents a general framework for assessing imaging systems and image-analysis methods on the basis of therapeutic rather than diagnostic efficacy. By analogy to receiver operating characteristic (ROC) curves, it utilizes the Therapy Operating Characteristic or TOC curve, which is a plot of the probability of tumor control vs. the probability of normal-tissue complications as the overall level of a radiotherapy treatment beam is varied. The proposed figure of merit is the area under the TOC, denoted AUTOC. If the treatment planning algorithm is held constant, AUTOC is a metric for the imaging and image-analysis components, and in particular for segmentation algorithms that are used to delineate tumors and normal tissues. On the other hand, for a given set of segmented images, AUTOC can also be used as a metric for the treatment plan itself. A general mathematical theory of TOC and AUTOC is presented and then specialized to segmentation problems. Practical approaches to implementation of the theory in both simulation and clinical studies are presented. The method is illustrated with a a brief study of segmentation methods for prostate cancer.

  13. Characteristic overpressure-impulse-distance curves for vapour cloud explosions using the TNO Multi-Energy model.

    PubMed

    Díaz Alonso, Fernando; González Ferradás, Enrique; Sánchez Pérez, Juan Francisco; Miñana Aznar, Agustín; Ruiz Gimeno, José; Martínez Alonso, Jesús

    2006-09-21

    A number of models have been proposed to calculate overpressure and impulse from accidental industrial explosions. When the blast is produced by ignition of a vapour cloud, the TNO Multi-Energy model is widely used. From the curves given by this model, data are fitted to obtain equations showing the relationship between overpressure, impulse and distance. These equations, referred herein as characteristic curves, can be fitted by means of power equations, which depend on explosion energy and charge strength. Characteristic curves allow the determination of overpressure and impulse at each distance.

  14. Application of Receiver Operating Characteristic (ROC) Curves for Explosives Detection Using Different Sampling and Detection Techniques

    PubMed Central

    Young, Mimy; Fan, Wen; Raeva, Anna; Almirall, Jose

    2013-01-01

    Reported for the first time are receiver operating characteristic (ROC) curves constructed to describe the performance of a sorbent-coated disk, planar solid phase microextraction (PSPME) unit for non-contact sampling of a variety of volatiles. The PSPME is coupled to ion mobility spectrometers (IMSs) for the detection of volatile chemical markers associated with the presence of smokeless powders, model systems of explosives containing diphenylamine (DPA), 2,4-dinitrotoluene (2,4-DNT) and nitroglycerin (NG) as the target analytes. The performance of the PSPME-IMS was compared with the widely accepted solid-phase microextraction (SPME), coupled to a GC-MS. A set of optimized sampling conditions for different volume containers (1–45 L) with various sample amounts of explosives, were studied in replicates (n = 30) to determine the true positive rates (TPR) and false positive detection rates (FPR) for the different scenarios. These studies were obtained in order to construct the ROC curves for two IMS instruments (a bench-top and field-portable system) and a bench top GC-MS system in low and high clutter environments. Both static and dynamic PSPME sampling were studied in which 10–500 mg quantities of smokeless powders were detected within 10 min of static sampling and 1 min of dynamic sampling.

  15. Soil water repellency characteristic curves for soil profiles with natural organic carbon gradients

    NASA Astrophysics Data System (ADS)

    Kawamoto, Ken; Müller, Karin; Moldrup, Per; de Jonge, Lis; Clothier, Brent; Hiradate, Syuntaro; Komatsu, Toshiko

    2014-05-01

    Soil water repellency (SWR) is a phenomenon that influences many soil hydrologic processes such as reduction of infiltration, increase in overland flow, and enhanced preferential flow. SWR has been observed in various soil types and textures, and the degree of SWR is greatly controlled by soil moisture content and levels of organic matter and clay. One of the key topics in SWR research is how to describe accurately the seasonal and temporal variation of SWR with the controlling factors such as soil moisture, organic matter, and clay contents for soil profiles with natural organic carbon gradients. In the present study, we summarize measured SWR data for soil profiles under different land uses and vegetation in Japan and New Zealand, and compared these with literature data. We introduce the contact angle-based evaluation of SWR and predictive models for soil water repellency characteristic curves, in which the contact angle is a function of the moisture content. We also discuss a number of novel concepts, including i) the reduction in the contact angle with soil-water contact time to describe the time dependence of SWR, ii) the relationship between the contact angles from the measured scanning curves under controlled wetting and drying cycles, and iii) the initial contact angles measured by the sessile drop method.

  16. Interrelations among the soil-water retention, hydraulic conductivity, and suction-stress characteristic curves

    USGS Publications Warehouse

    Lu, Ning; Kaya, Murat; Godt, Jonathan W.

    2014-01-01

    The three fundamental constitutive relations that describe fluid flow, strength, and deformation behavior of variably saturated soils are the soil-water retention curve (SWRC), hydraulic conductivity function (HCF), and suction-stress characteristic curve (SSCC). Until recently, the interrelations among the SWRC, HCF, and SSCC have not been well established. This work sought experimental confirmation of interrelations among these three constitutive functions. Results taken from the literature for six soils and those obtained for 11 different soils were used. Using newly established analytical relations among the SWRC, HCF, and SSCC and these test results, the authors showed that these three constitutive relations can be defined by a common set of hydromechanical parameters. The coefficient of determination for air-entry pressures determined independently using hydraulic and mechanical methods is >0.99, >0.98 for the pore size parameter, and 0.94 for the residual degree of saturation. One practical implication is that one of any of the four experiments (axis-translation, hydraulic, shear-strength, or deformation) is sufficient to quantify all three constitutive relations.

  17. Receiver operator characteristic (ROC) curves and non-normal data: an empirical study.

    PubMed

    Goddard, M J; Hinberg, I

    1990-03-01

    This paper evaluates the performance of several diagnostic kits for assessing levels of serum prostatic acid phosphatase on patients at different stages of cancer of the prostate. Each patient was studied with several kits. We compare results obtained for receiver operator characteristic (ROC) curve methodology with data assumed to follow a normal distribution, with log-transformed data assumed to follow a normal distribution, and when neither of these assumptions holds. There were important differences between the results of the different approaches. For these data, the normal distribution assumption should be used with extreme caution. The log-transformed based results compared favourably with the non-parametric, but unconsidered application of the method should be avoided.

  18. Fully non-parametric receiver operating characteristic curve estimation for random-effects meta-analysis.

    PubMed

    Martínez-Camblor, Pablo

    2017-02-01

    Meta-analyses, broadly defined as the quantitative review and synthesis of the results of related but independent comparable studies, allow to know the state of the art of one considered topic. Since the amount of available bibliography has enhanced in almost all fields and, specifically, in biomedical research, its popularity has drastically increased during the last decades. In particular, different methodologies have been developed in order to perform meta-analytic studies of diagnostic tests for both fixed- and random-effects models. From a parametric point of view, these techniques often compute a bivariate estimation for the sensitivity and the specificity by using only one threshold per included study. Frequently, an overall receiver operating characteristic curve based on a bivariate normal distribution is also provided. In this work, the author deals with the problem of estimating an overall receiver operating characteristic curve from a fully non-parametric approach when the data come from a meta-analysis study i.e. only certain information about the diagnostic capacity is available. Both fixed- and random-effects models are considered. In addition, the proposed methodology lets to use the information of all cut-off points available (not only one of them) in the selected original studies. The performance of the method is explored through Monte Carlo simulations. The observed results suggest that the proposed estimator is better than the reference one when the reported information is related to a threshold based on the Youden index and when information for two or more points are provided. Real data illustrations are included.

  19. Prediction of dynamic and aerodynamic characteristics of the centrifugal fan with forward curved blades

    NASA Astrophysics Data System (ADS)

    Polanský, Jiří; Kalmár, László; Gášpár, Roman

    2013-12-01

    The main aim of this paper is determine the centrifugal fan with forward curved blades aerodynamic characteristics based on numerical modeling. Three variants of geometry were investigated. The first, basic "A" variant contains 12 blades. The geometry of second "B" variant contains 12 blades and 12 semi-blades with optimal length [1]. The third, control variant "C" contains 24 blades without semi-blades. Numerical calculations were performed by CFD Ansys. Another aim of this paper is to compare results of the numerical simulation with results of approximate numerical procedure. Applied approximate numerical procedure [2] is designated to determine characteristics of the turbulent flow in the bladed space of a centrifugal-flow fan impeller. This numerical method is an extension of the hydro-dynamical cascade theory for incompressible and inviscid fluid flow. Paper also partially compares results from the numerical simulation and results from the experimental investigation. Acoustic phenomena observed during experiment, during numerical simulation manifested as deterioration of the calculation stability, residuals oscillation and thus also as a flow field oscillation. Pressure pulsations are evaluated by using frequency analysis for each variant and working condition.

  20. Potential distribution and transmission characteristics in a curved quadrupole ion guide.

    PubMed

    Zhou, Xiaoyu; Xiong, Caiqiao; Xu, Gaoping; Liu, Hao; Tang, Yin; Zhu, Zhiqiang; Chen, Rui; Qiao, Haoxue; Tseng, Yao-Hsin; Peng, Wen-Ping; Nie, Zongxiu; Chen, Yi

    2011-02-01

    The potential distribution in the curved quadrupole is exactly characterized by the Laplace equation, and an approximate solution to the Laplace equation is calculated. We represent the Laplace equation under the coordinates named minimal rotation frame (MRF) and derive an expression on the hexapole and octopole superposition. Our conclusion is in agreement with the results by the numerical (SIMION) method. Based on the Poincare-Lighthill-Kuo (PLK) method reported in our previous work, the nonlinear effects of ion motion are investigated in detail. The frequency shift of ion motion can be well eliminated by coupling the hexapole component with a positive octopole component, and the transmission efficiency of ions is found to decrease dramatically with the increase of the ionic kinetic energy in the z-direction. Furthermore, the transmission characteristics of ions are discussed with regards to the phase-space theory. The results show that the centrifugally introduced axis shift is mainly responsible for the ion losses. A modified direct current (dc) voltage supply pattern is hence proposed to compensate for this effect.

  1. Word Frequency and Receiver Operating Characteristic Curves in Recognition Memory: Evidence for a Dual-Process Interpretation

    PubMed Central

    Arndt, Jason; Reder, Lynne M.

    2008-01-01

    Dual-process models of the word-frequency mirror effect posit that low-frequency words are recollected more often than high-frequency words, producing the hit rate differences in the word-frequency effect, whereas high-frequency words are more familiar, producing the false-alarm-rate differences. In this pair of experiments, the authors demonstrate that the analysis of receiver operating characteristic (ROC) curves provides critical information in support of this interpretation. Specifically, when participants were required to discriminate between studied nouns and their plurality reversed complements, the ROC curve was accurately described by a threshold model that is consistent with recollection-based recognition. Further, the plurality discrimination ROC curves showed characteristics consistent with the interpretation that participants recollected low-frequency items more than high-frequency items. PMID:12219793

  2. 7 CFR 42.140 - Operating Characteristic (OC) curves for on-line sampling and inspection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Plan. An examination of this table reveals that there is one single and one double sampling plan that have OC curves comparable to OC curve 6. The first plan listed is a single plan requiring the... if there are 3 or more defects in the sample. In the event that the number of defects is between...

  3. A Statistical Comparison of the Blossom Blight Forecasts of MARYBLYT and Cougarblight with Receiver Operating Characteristic Curve Analysis

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Blossom blight forecasting is an important aspect of fire blight, caused by Erwinia amylovora, management for both apple and pear. A comparison of the forecast accuracy of two common fire blight forecasters, MARYBLYT and Cougarblight, was performed with receiver operating characteristic (ROC) curve ...

  4. The Obsessive Compulsive Scale of the Child Behavior Checklist Predicts Obsessive-Compulsive Disorder: A Receiver Operating Characteristic Curve Analysis

    ERIC Educational Resources Information Center

    Hudziak, James J.; Althoff, Robert R.; Stanger, Catherine; van Beijsterveldt, C. E. M.; Nelson, Elliot C.; Hanna, Gregory L.; Boomsma, Dorret I.; Todd, Richard D.

    2006-01-01

    Background: The purpose of this study was to determine a score on the Obsessive Compulsive Scale (OCS) from the Child Behavior Checklist (CBCL) to screen for obsessive compulsive disorder (OCD) in children and to rigorously test the specificity and sensitivity of a single cutpoint. Methods: A receiver operating characteristic (ROC) curve analysis…

  5. Learner Characteristic Based Learning Effort Curve Mode: The Core Mechanism on Developing Personalized Adaptive E-Learning Platform

    ERIC Educational Resources Information Center

    Hsu, Pi-Shan

    2012-01-01

    This study aims to develop the core mechanism for realizing the development of personalized adaptive e-learning platform, which is based on the previous learning effort curve research and takes into account the learner characteristics of learning style and self-efficacy. 125 university students from Taiwan are classified into 16 groups according…

  6. The soil water characteristic as new class of closed-form parametric expressions for the flow duration curve

    NASA Astrophysics Data System (ADS)

    Sadegh, M.; Vrugt, J. A.; Gupta, H. V.; Xu, C.

    2016-04-01

    The flow duration curve is a signature catchment characteristic that depicts graphically the relationship between the exceedance probability of streamflow and its magnitude. This curve is relatively easy to create and interpret, and is used widely for hydrologic analysis, water quality management, and the design of hydroelectric power plants (among others). Several mathematical expressions have been proposed to mimic the FDC. Yet, these efforts have not been particularly successful, in large part because available functions are not flexible enough to portray accurately the functional shape of the FDC for a large range of catchments and contrasting hydrologic behaviors. Here, we extend the work of Vrugt and Sadegh (2013) and introduce several commonly used models of the soil water characteristic as new class of closed-form parametric expressions for the flow duration curve. These soil water retention functions are relatively simple to use, contain between two to three parameters, and mimic closely the empirical FDCs of 430 catchments of the MOPEX data set. We then relate the calibrated parameter values of these models to physical and climatological characteristics of the watershed using multivariate linear regression analysis, and evaluate the regionalization potential of our proposed models against those of the literature. If quality of fit is of main importance then the 3-parameter van Genuchten model is preferred, whereas the 2-parameter lognormal, 3-parameter GEV and generalized Pareto models show greater promise for regionalization.

  7. Physical Characteristics of Faint Meteors by Light Curve and High-resolution Observations

    NASA Astrophysics Data System (ADS)

    Subasinghe, Dilini; Campbell-Brown, Margaret D.; Stokan, Edward

    2014-11-01

    The physical structure of a meteoroid may be inferred from optical observations, particularly the light curve, of a meteor. For example: a classically shaped (late peaked) light curve is seen as evidence of a solid single body, whereas a symmetric light curve may indicate a dustball structure. High-resolution optical observations show how the meteoroid fragments: continuously, leaving a long wake, or discretely, leaving several distinct pieces. Calculating the orbit of the meteoroid using two station data then allows the object to be associated with asteroidal or cometary parent bodies. Optical observations thus provide simultaneous information on meteoroid structure, fragmentation mode, and origin.CAMO (the Canadian Automated Meteor Observatory) has been continuously collecting faint (masses < 10-4 kg) two station optical meteors with image-intensified narrow field (with a resolution of up to 3 meters per pixel) and wide field (26 by 19 degrees) cameras since 2010. The narrow field, telescopic cameras allow the meteor fragmentation to be studied using a pair of mirrors to track the meteor. The wide-field cameras provide the light curve and trajectory solution.We present preliminary results from classifying light curves and high-resolution optical observations for 3000 faint meteors recorded since 2010. We find that most meteors (both asteroidal and cometary) show long trails, while meteors with short trails are the second most common morphology. It is expected that meteoroids that experience negligible fragmentation have the shortest trails, so our results imply that the majority of small meteoroids fragment during ablation. A surprising observation is that almost equal fractions of asteroidal and cometary meteors fragment (showing long trails), implying a similar structure for both types of meteoroids.

  8. Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Kelly, Ryan T.; Marginean, Ioan; Tang, Keqi

    2014-06-13

    Electrospray Ionization (ESI) is a process whereby gas phase ions are created from molecules in solution. As a solution exits a narrow tube in the presence of a strong electric field, an aerosol of charged droplets are is formed that produces gas phase ions as they it desolvates. ESI-MS comprises the creation of ions by ESI and the determination of their mass to charge ratio (m/z) by MS.

  9. 7 CFR 42.140 - Operating Characteristic (OC) curves for on-line sampling and inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Units Comparable sampling plans Identification number of OC curve R1 nc Ac Re R2 nc Ac Re R3 nc Ac Re R4 nc Ac Re N4 nc Ac Re N5 nc Ac Re N6 nc Ac Re N7 nc Ac Re N8 nc Ac Re Single 29 1 2 84 1 2 126 0 1 315... 36 1 2 96 1 2 180 1 2 336 1 2 540 2 3 864 3 4 nc=Cumulative sample size.Ac=Acceptance...

  10. 7 CFR 42.140 - Operating Characteristic (OC) curves for on-line sampling and inspection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Units Comparable sampling plans Identification number of OC curve R1 nc Ac Re R2 nc Ac Re R3 nc Ac Re R4 nc Ac Re N4 nc Ac Re N5 nc Ac Re N6 nc Ac Re N7 nc Ac Re N8 nc Ac Re Single 29 1 2 84 1 2 126 0 1 315... 36 1 2 96 1 2 180 1 2 336 1 2 540 2 3 864 3 4 nc=Cumulative sample size.Ac=Acceptance...

  11. Electrospraying from nanofluidic capillary slot

    NASA Astrophysics Data System (ADS)

    Arscott, Steve; Troadec, David

    2005-09-01

    We present here an original electrospray emitter tip based on a nanofluidic capillary slot. The nanofabrication involves focused ion beam etching to form the slot which has a cross-section of 50×300nm and a length of 4μm. The liquid is deformed into the nanofluidic capillary slot by capillary action; the electrospray is produced by the application of a low voltage. Using a water-methanol-formic acid solution, we have observed an electrospray onset voltage of 125V. At a measured electrospray current of 1nA, the unforced flow-rate is estimated to be 110pLmin-1.

  12. Understanding the effect of watershed characteristic on the runoff using SCS curve number

    NASA Astrophysics Data System (ADS)

    Damayanti, Frieta; Schneider, Karl

    2015-04-01

    Runoff modeling is a key component in watershed management. The temporal course and amount of runoff is a complex function of a multitude of parameters such as climate, soil, topography, land use, and water management. Against the background of the current rapid environmental change, which is due to both i) man-made changes (e.g. urban development, land use change, water management) as well as ii) changes in the natural systems (e.g. climate change), understanding and predicting the impacts of these changes upon the runoff is very important and affects the wellbeing of many people living in the watershed. A main tool for predictions is hydrologic models. Particularly process based models are the method of choice to assess the impact of land use and climate change. However, many regions which experience large changes in the watersheds can be described as rather data poor, which limits the applicability of such models. This is particularly also true for the Telomoyo Watershed (545 km2) which is located in southern part of Central Java province. The average annual rainfall of the study area reaches 2971 mm. Irrigated paddy field are the dominating land use (35%), followed by built-up area and dry land agriculture. The only available soil map is the FAO soil digital map of the world, which provides rather general soil information. A field survey accompanied by a lab analysis 65 soil samples of was carried out to provide more detailed soil texture information. The soil texture map is a key input in the SCS method to define hydrological soil groups. In the frame of our study on 'Integrated Analysis on Flood Risk of Telomoyo Watershed in Response to the Climate and Land Use Change' funded by the German Academic Exchange service (DAAD) we analyzed the sensitivity of the modeled runoff upon the choice of the method to estimate the CN values using the SCS-CN method. The goal of this study is to analyze the impact of different data sources on the curve numbers and the

  13. The influence of acceleration loading curve characteristics on traumatic brain injury.

    PubMed

    Post, Andrew; Blaine Hoshizaki, T; Gilchrist, Michael D; Brien, Susan; Cusimano, Michael D; Marshall, Shawn

    2014-03-21

    To prevent brain trauma, understanding the mechanism of injury is essential. Once the mechanism of brain injury has been identified, prevention technologies could then be developed to aid in their prevention. The incidence of brain injury is linked to how the kinematics of a brain injury event affects the internal structures of the brain. As a result it is essential that an attempt be made to describe how the characteristics of the linear and rotational acceleration influence specific traumatic brain injury lesions. As a result, the purpose of this study was to examine the influence of the characteristics of linear and rotational acceleration pulses and how they account for the variance in predicting the outcome of TBI lesions, namely contusion, subdural hematoma (SDH), subarachnoid hemorrhage (SAH), and epidural hematoma (EDH) using a principal components analysis (PCA). Monorail impacts were conducted which simulated falls which caused the TBI lesions. From these reconstructions, the characteristics of the linear and rotational acceleration were determined and used for a PCA analysis. The results indicated that peak resultant acceleration variables did not account for any of the variance in predicting TBI lesions. The majority of the variance was accounted for by duration of the resultant and component linear and rotational acceleration. In addition, the components of linear and rotational acceleration characteristics on the x, y, and z axes accounted for the majority of the remainder of the variance after duration.

  14. Electrosprayed nanoparticles for drug delivery and pharmaceutical applications

    PubMed Central

    Sridhar, Radhakrishnan; Ramakrishna, Seeram

    2013-01-01

    Nanotechnology based Pharma has emerged significantly and has influenced the Pharma industry up to a considerable extent. Nanoparticles technology holds a good share of the nanotech Pharma and is significant in comparison with the other domains. Electrospraying technology answers the potential needs of nanoparticle production such as scalability, reproducibility, effective encapsulation etc. Many drugs have been electrosprayed with and without polymer carriers. Drug release characteristics are improved with the incorporation of biodegradable polymer carriers which sustain the release of encapsulated drug. Electrospraying is acknowledged as an important technique for the preparation of nanoparticles with respect to pharmaceutical applications. Herein we attempted to consolidate the reports pertaining to electrospraying and their corresponding therapeutic application area. PMID:23512013

  15. The Soil-Water Characteristic Curve of Unsaturated Tropical Residual Soil

    NASA Astrophysics Data System (ADS)

    Yusof, M. F.; Setapa, A. S.; Tajudin, S. A. A.; Madun, A.; Abidin, M. H. Z.; Marto, A.

    2016-07-01

    This study was conducted to determine the SWCC of unsaturated tropical residual soil in Kuala Lumpur, Malaysia. Undisturbed soil samples at five locations of high-risk slopes area were taken at a depth of 0.5 m using block sampler. In the determination of the SWCC, the pressure plate extractor with the capacity of 1500 kN/m2 has been used. The index properties of the soil such as natural moisture content, Atterberg limits, specific gravity, and soil classification are performed according to BS 1377: Part 2: 1990. The results of index properties show that the natural moisture content of the soil is between 36% to 46%, the plasticity index is between 10% - 26%, the specific gravity is between 2.51 - 2.61 and the soils is classified as silty organic clay of low plasticity. The SWCC data from the pressure plate extractor have been fitted with the Fredlund and Xing equation. The results show that the air entry value and residual matric suction for residual soils are in the range of 17 kN/m2 to 24 kN/m2 and 145 kN/m2 to 225 kN/m2 respectively. From the fitting curve, it is found that the average value of the Fredlund and Xing parameters such as a, n and m are in the range of 0.24-0.299, 1.7-4.8 and 0.142-0.440 respectively.

  16. Investigation of Liner Characteristics in the NASA Langley Curved Duct Test Rig

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Brown, Martha C.; Watson, Willie R.; Jones, Michael G.

    2007-01-01

    The Curved Duct Test Rig (CDTR), which is designed to investigate propagation of sound in a duct with flow, has been developed at NASA Langley Research Center. The duct incorporates an adaptive control system to generate a tone in the duct at a specific frequency with a target Sound Pressure Level and a target mode shape. The size of the duct, the ability to isolate higher order modes, and the ability to modify the duct configuration make this rig unique among experimental duct acoustics facilities. An experiment is described in which the facility performance is evaluated by measuring the sound attenuation by a sample duct liner. The liner sample comprises one wall of the liner test section. Sound in tones from 500 to 2400 Hz, with modes that are parallel to the liner surface of order 0 to 5, and that are normal to the liner surface of order 0 to 2, can be generated incident on the liner test section. Tests are performed in which sound is generated without axial flow in the duct and with flow at a Mach number of 0.275. The attenuation of the liner is determined by comparing the sound power in a hard wall section downstream of the liner test section to the sound power in a hard wall section upstream of the liner test section. These experimentally determined attenuations are compared to numerically determined attenuations calculated by means of a finite element analysis code. The code incorporates liner impedance values educed from measured data from the NASA Langley Grazing Incidence Tube, a test rig that is used for investigating liner performance with flow and with (0,0) mode incident grazing. The analytical and experimental results compare favorably, indicating the validity of the finite element method and demonstrating that finite element prediction tools can be used together with experiment to characterize the liner attenuation.

  17. Flow visualization of time-varying structural characteristics of dean vortices in a curved channel

    NASA Astrophysics Data System (ADS)

    Bella, David Wayne

    1988-12-01

    The time varying development and structure of Dean vortices were studied using flow visualization. Observations were made over a range of Dean numbers from 40 to 200 using a transparent channel with mild curvature, 40:1 aspect ratio, and an inner to outer radius ratio of 0.979. Seven flow visualization techniques were tried but only one, a wood burning smoke generator, produced usable results. Different vortex characteristics were observed and documented in sequences of photographs spaced one quarter of a second apart at locations ranging from 85 to 135 degrees from the start of curvature. Evidence is presented that supports the twisting/rocking nature of the flow.

  18. Magnetic Characteristics of Electromagnetic Levitation System for Short Radius Curve Track

    NASA Astrophysics Data System (ADS)

    Nomiyama, Takuma; Kakinoki, Toshio; Yamaguchi, Hitoshi; Jifuku, Yorito; Mochizuki, Takuro

    A magnetically levitated (MAGLEV) vehicle using electro-magnets and iron rails generates lateral guiding force naturally by controlling levitation force to maintain the air gaps between the magnets and the iron rails. A MAGLEV system without guide magnets offers simple design and cost advantages. But such a system has little lateral damping force. In order to improve damping characteristics, an experimental apparatus using salient-pole type magnets and laminated iron rails was made. The iron cores were placed in two rows. The levitation coils surrounded both of the magnet iron cores and the damping coils surrounded every magnet cores separately. The damping coils were excited by currents proportional to the lateral displacement velocity. According to a step response experiment, the lateral motion dissipated after a cycle or two of the swing. The self-inductance of the levitation coil of the magnet almost unchanged against variation of the lateral displacement. The influence of damping current on the levitation was very small. In this paper electromagnetic characteristics of the levitation system are shown.

  19. Regional Curves for Bankfull Channel Characteristics in the Appalachian Plateaus, West Virginia

    USGS Publications Warehouse

    Messinger, Terence

    2009-01-01

    Streams in the Appalachian Plateaus Physiographic Province in West Virginia were classified as a single region on the basis of bankfull characteristics. Regression lines for annual peak flow and drainage area measured at streamgages in the study area at recurrence intervals between 1.2 and 1.7 years fell within the 99-percent confidence interval of the regression line for bankfull flow. Channel characteristics were intermediate among those from surrounding states and regions where comparable studies have been done. The stream reaches that were surveyed were selected for apparent stability, and to represent gradients of drainage area, elevation, and mean annual precipitation. Profiles of high-water marks left by bankfull and near-bankfull peaks were surveyed, either as part of slope-area flow measurements at ungaged reaches, or to transfer known flow information to cross sections for gaged reaches. The slope-area measurements made it possible to include ungaged sites in the study, but still relate bankfull dimensions to peak flow and frequency.

  20. Classification of breast mass lesions using model-based analysis of the characteristic kinetic curve derived from fuzzy c-means clustering.

    PubMed

    Chang, Yeun-Chung; Huang, Yan-Hao; Huang, Chiun-Sheng; Chang, Pei-Kang; Chen, Jeon-Hor; Chang, Ruey-Feng

    2012-04-01

    The purpose of this study is to evaluate the diagnostic efficacy of the representative characteristic kinetic curve of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) extracted by fuzzy c-means (FCM) clustering for the discrimination of benign and malignant breast tumors using a novel computer-aided diagnosis (CAD) system. About the research data set, DCE-MRIs of 132 solid breast masses with definite histopathologic diagnosis (63 benign and 69 malignant) were used in this study. At first, the tumor region was automatically segmented using the region growing method based on the integrated color map formed by the combination of kinetic and area under curve color map. Then, the FCM clustering was used to identify the time-signal curve with the larger initial enhancement inside the segmented region as the representative kinetic curve, and then the parameters of the Tofts pharmacokinetic model for the representative kinetic curve were compared with conventional curve analysis (maximal enhancement, time to peak, uptake rate and washout rate) for each mass. The results were analyzed with a receiver operating characteristic curve and Student's t test to evaluate the classification performance. Accuracy, sensitivity, specificity, positive predictive value and negative predictive value of the combined model-based parameters of the extracted kinetic curve from FCM clustering were 86.36% (114/132), 85.51% (59/69), 87.30% (55/63), 88.06% (59/67) and 84.62% (55/65), better than those from a conventional curve analysis. The A(Z) value was 0.9154 for Tofts model-based parametric features, better than that for conventional curve analysis (0.8673), for discriminating malignant and benign lesions. In conclusion, model-based analysis of the characteristic kinetic curve of breast mass derived from FCM clustering provides effective lesion classification. This approach has potential in the development of a CAD system for DCE breast MRI.

  1. A Statistical Comparison of the Blossom Blight Forecasts of MARYBLYT and Cougarblight with Receiver Operating Characteristic Curve Analysis.

    PubMed

    Dewdney, M M; Biggs, A R; Turechek, W W

    2007-09-01

    ABSTRACT Blossom blight forecasting is an important aspect of fire blight, caused by Erwinia amylovora, management for both apple and pear. A comparison of the forecast accuracy of two common fire blight forecasters, MARYBLYT and Cougarblight, was performed with receiver operating characteristic (ROC) curve analysis and 243 data sets. The rain threshold of Cougarblight was analyzed as a separate model termed Cougarblight and rain. Data were used as a whole and then grouped into geographic regions and cultivar susceptibilities. Frequency distributions of cases and controls, orchards or regions (depending on the data set), with and without observed disease, respectively, in all data sets overlapped. MARYBLYT, Cougarblight, and Cougarblight and rain all predicted blossom blight infection better than chance (P = 0.05). It was found that the blossom blight forecasters performed equivalently in the geographic regions of the east and west coasts of North America and moderately susceptible cultivars based on the 95% confidence intervals and pairwise contrasts of the area under the ROC curve. Significant differences (P < 0.05) between the forecasts of Cougarblight and MARYBLYT were found with pairwise contrasts in the England and very susceptible cultivar data sets. Youden's index was used to determine the optimal cutpoint of both forecasters. The greatest sensitivity and specificity for MARYBLYT coincided with the use of the highest risk threshold for predictions of infection; with Cougarblight, there was no clear single risk threshold across all data sets.

  2. Evaluation of volume and total nucleated cell count as cord blood selection parameters: a receiver operating characteristic curve modeling approach.

    PubMed

    Jaime-Pérez, José C; Monreal-Robles, Roberto; Rodríguez-Romo, Laura N; Mancías-Guerra, Consuelo; Herrera-Garza, José Luís; Gómez-Almaguer, David

    2011-11-01

    The objective of the study was to evaluate the current standard practice of using volume and total nucleated cell (TNC) count for the selection of cord blood (CB) units for cryopreservation and further transplantation. Data on 794 CB units whose CD34+ cell content was determined by flow cytometry were analyzed by using a receiver operating characteristic (ROC) curve model to validate the performance of volume and TNC count for the selection of CB units with grafting purposes. The TNC count was the best parameter to identify CB units having 2 × 10(6) or more CD34+ cells, with an area under the ROC curve of 0.828 (95% confidence interval, 0.800-0.856; P < .01) and an efficiency of 75.4%. Combination of parameters (TNC/mononuclear cells [MNCs], efficiency 74.7%; TNC/volume, efficiency 68.9%; and volume/MNCs, efficiency 68.3%) did not lead to improvement in CB selection. All CB units having a TNC count of 8 × 10(8) or more had the required CD34+ cell dose for patients weighing 10 kg or less.

  3. Prediction of preterm and low birth weight delivery by maternal periodontal parameters: receiver operating characteristic (ROC) curve analysis.

    PubMed

    Al Habashneh, Rola; Khader, Yousef S; Jabali, Olfat Al; Alchalabi, Haifa'a

    2013-02-01

    In this study we used receiver-operating characteristic (ROC) analysis to comparatively evaluate maternal periodontal parameters to predict preterm (PB) delivery and low birth weight (LBW) delivery among Jordanian women. A total of 277 pregnant women (20 weeks of gestation or less) had periodontal examination at baseline and followed up until delivery. Gestational age and birth weight were retrieved from their medical records. ROC curve analyses were used to examine the overall discriminatory power of the studied periodontal parameters to predict PB, LBW, and PB or LBW. For the three outcome variables, the area under curve (AUC) ranged from 0.84 to 0.87 for average clinical attachment level (CAL), 0.78-0.86 for percent of sites with CAL ≥ 5 mm, 0.63-0.74 for percent of sites with CAL ≥ 6 mm, and 0.71-0.82 for number of missing teeth indicating that they had high discriminating power to predict adverse pregnancy outcomes. All other parameters had AUC less than 0.60 and thus had low discriminating power. Average CAL performed the best in predicting the studied adverse pregnancy outcomes because it has the highest AUC. The severity and extent of periodontal disease as measured by CAL can be used to predict the occurrence of adverse pregnancy outcomes.

  4. Effects of bottom bracings on torsional dynamic characteristics of horizontally curved twin I-girder bridges with different curvatures

    NASA Astrophysics Data System (ADS)

    Awall, Md. Robiul; Hayashikawa, Toshiro; Matsumoto, Takashi; He, Xingwen

    2012-03-01

    Curved twin I-girder bridges (CTIGBs) have low torsional stiffness that makes them vulnerable to dynamic loads. This study investigates the effects of bottom bracings on the torsional dynamic characteristics of CTIGBs. Five types of bottom bracings are designed to investigate their effects on the dynamic characteristics of CTIGBs with different curvatures under free and forced vibrations. To perform numerical investigations, three-dimensional (3-D) finite element (FE) bridge and vehicle models are established using commercial ANSYS code, and then a vehicle-bridge interaction analysis approach is proposed. Road roughness profiles generated from power spectral density and cross spectral functions are also taken into account in the analyses. The numerical results show that torsional frequencies increase significantly after providing bottom bracings, and the increasing rate depends on the type of bottom bracings and their locations of installation. Bottom bracings can act as load transmitting members from one main girder to the others. Large negative bearing forces that have occurred in bridges with small radii of curvatures can be remarkably reduced by providing bottom bracing systems. It is found that the performances of several bottom bracing systems are effective in improving the torsional dynamic characteristics of the bridges in this study.

  5. Characteristics of shut-in curves in hydraulic fracturing stress measurements and determination of in situ minimum compressive stress

    NASA Astrophysics Data System (ADS)

    Hayashi, Kazuo; Haimson, Bezalel C.

    1991-10-01

    Characteristics of pressure decay curves obtained after shut-in in hydraulic fracturing stress measurements are studied in detail in an effort to enhance the reliability of the minimum compressive in situ stress determination. The analysis utilizes linear theory of elasticity, fracture mechanics, and global mass balance of fracturing fluid after shut-in. A small amount of crack growth takes place almost instantaneously just after shut-in due to equilibration of injected-fluid pressure within the fracture. Thereafter, the fracture gradually closes commensurate with the amount of fluid leakage into the rock and the net compliance of the pressured system consisting of the rock, the fracture, and the tubing conveying pressurized fluid from the surface to the depth of testing. Theoretical considerations and laboratory and field data suggest the closure process after shut-in can be considered to consist of three major stages: from cessation of fracture growth until fracture tip closure (stage I), from just after fracture tip closure until complete fracture closure (stage II), and from just after complete fracture closure until the test is stopped (stage III). An analysis of these stages reveals that the inverse of the pressure decrease rate is linear with respect to the fluid pressure in stages I and III. It is also shown that the far-field minimum compressive stress can be determined on the basis of these characteristics. The method of determination of the in situ minimum compressive stress is successfully applied to a sampling of shut-in curves obtained in laboratory and field experiments.

  6. Evaluation of Models for Alternaria Brown Spot of Mandarin Under Mediterranean Conditions by Partial Receiver Operating Characteristic Curve Analysis.

    PubMed

    Bassimba, Daniel D M; Mira, Jose L; Vicent, Antonio

    2017-04-12

    Alternaria brown spot (ABS) is a serious fungal disease of mandarin in the Mediterranean Basin. Due to the rigorous fruit quality standards, models for ABS should avoid false negatives. Experiments were conducted with susceptible 'Fortune' and 'Nova' inoculated at different temperatures and leaf wetness durations, including interrupted periods. Effects of temperature and time elapsed after inoculation were also studied. Disease incidence data were fitted to generalized additive models and a generic infection model. Exposure of trap plants in affected orchards was used for model evaluation, including the Alter-Rater and a simple rule system (SRS). The predictive ability of the models was analyzed using the partial area under the receiver operating characteristic curve in the high-sensitivity range between 0.9 and 1. Postinoculation temperature had a significant effect on disease incidence, with maximum symptom expression after 30 h on Fortune and 60 h on Nova. ABS incidence did not increase after a leaf wetness interruption of 1 h on Nova and 2 h on Fortune. All the models evaluated had high false-positive rates on Fortune. Only the SRS showed a substantial strength of agreement in Nova, with a true-positive rate of 0.93 and false-positive rate of 0.16.

  7. Fractal Characteristics of Soil Retention Curve and Particle Size Distribution with Different Vegetation Types in Mountain Areas of Northern China.

    PubMed

    Niu, Xiang; Gao, Peng; Wang, Bing; Liu, Yu

    2015-12-03

    Based on fractal theory, the fractal characteristics of soil particle size distribution (PSD) and soil water retention curve (WRC) under the five vegetation types were studied in the mountainous land of Northern China. Results showed that: (1) the fractal parameters of soil PSD and soil WRC varied greatly under each different vegetation type, with Quercus acutissima Carr. and Robina pseudoacacia Linn. mixed plantation (QRM) > Pinus thunbergii Parl. and Pistacia chinensis Bunge mixed plantation (PPM) > Pinus thunbergii Parl. (PTP) > Juglans rigia Linn. (JRL) > abandoned grassland (ABG); (2) the soil fractal dimensions of woodlands (QRM, PPM, PTP and JRL) were significantly higher than that in ABG, and mixed forests (QRM and PPM) were higher than that in pure forests (PTP and JRL); (3) the fractal dimension of soil was positively correlated with the silt and clay content but negatively correlated with the sand content; and (4) the fractal dimension of soil PSD was positively correlated with the soil WRC. These indicated that the fractal parameters of soil PSD and soil WRC could act as quantitative indices to reflect the physical properties of the soil, and could be used to describe the influences of the Return Farmland to Forests Projects on soil structure.

  8. Applications of electrospinning/electrospraying in drug delivery.

    PubMed

    Jahangiri, Azin; Adibkia, Khosro

    2016-01-01

    During recent years, nanoscaled materials have gained much attention because of their applications in the field of pharmaceutical and biomedical sciences. Electrospinning/electrospraying, as simple, effective and single-step methods, are used in the preparation of nanostructured materials (nanofibers and nanobeads). They offer an opportunity for direct encapsulation of the different types of drug molecules. The generated nanomaterials possess high surface area with porous characteristics, and the liberation of the loaded drugs follows a controlled-release pattern. Because of their wide applications in medical/pharmaceutical researches, the aim of this editorial is to highlight the importance of electrospinning/electrospraying technologies in drug delivery.

  9. Electrospray formation of ring-shaped silica nanoparticles

    NASA Astrophysics Data System (ADS)

    Uchida, Kazuhiro; Higashi, Kazuhiko; Hishida, Koichi; Hotta, Atsushi; Miki, Norihisa

    2015-02-01

    Electrospray is one of the processes employed for the production of silica nanoparticles (NPs). We have experimentally determined that not only spherical but also ring-shaped NPs can be manufactured by electrospray, and that the shape of the NPs is dependent on ambient humidity and the substrate on which the NPs are deposited. Although the effect of humidity that reflects the evaporation characteristics of the suspension during flight has been reported, we have experimentally determined that the affinity of the sol suspension and the substrate play a crucial role in the formation of torus silica NPs.

  10. Applications of electrospinning/electrospraying in drug delivery

    PubMed Central

    Jahangiri, Azin; Adibkia, Khosro

    2016-01-01

    During recent years, nanoscaled materials have gained much attention because of their applications in the field of pharmaceutical and biomedical sciences. Electrospinning/electrospraying, as simple, effective and single-step methods, are used in the preparation of nanostructured materials (nanofibers and nanobeads). They offer an opportunity for direct encapsulation of the different types of drug molecules. The generated nanomaterials possess high surface area with porous characteristics, and the liberation of the loaded drugs follows a controlled-release pattern. Because of their wide applications in medical/pharmaceutical researches, the aim of this editorial is to highlight the importance of electrospinning/electrospraying technologies in drug delivery. PMID:27340617

  11. 7 CFR 42.141 - Obtaining Operating Characteristic (OC) curve information for skip lot sampling and inspection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of 6.5. The OC curve for this sampling plan is curve N and R3. Also, assume that the quality of the lot is 6.5 defects per hundred units. From curve N and R3, then, the Pa is determined to be 95 percent. Then refer to the graph in § 42.142 and locate Pa of 95 percent along the horizontal axis. From...

  12. 7 CFR 42.141 - Obtaining Operating Characteristic (OC) curve information for skip lot sampling and inspection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... of 6.5. The OC curve for this sampling plan is curve N and R3. Also, assume that the quality of the lot is 6.5 defects per hundred units. From curve N and R3, then, the Pa is determined to be 95 percent. Then refer to the graph in § 42.142 and locate Pa of 95 percent along the horizontal axis. From...

  13. 7 CFR 42.141 - Obtaining Operating Characteristic (OC) curve information for skip lot sampling and inspection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of 6.5. The OC curve for this sampling plan is curve N and R3. Also, assume that the quality of the lot is 6.5 defects per hundred units. From curve N and R3, then, the Pa is determined to be 95 percent. Then refer to the graph in § 42.142 and locate Pa of 95 percent along the horizontal axis. From...

  14. Encapsulating darunavir nanocrystals within Eudragit L100 using coaxial electrospraying.

    PubMed

    Nguyen, Duong Nhat; Clasen, Christian; Van den Mooter, Guy

    2017-04-01

    Electrospraying is renowned for its simplicity and versatility, and which can effectively produce particles with well-controlled size, size distribution, particle shape, morphology and microstructure at the nano/microscale. In this study, coaxial electrospraying was used to investigate its feasibility for preparing nanoparticles made up of nanocrystals encapsulated within a polymer shell. Firstly, aqueous nanosuspensions of darunavir were prepared by wet media milling. Then the nanosuspension and solutions of an enteric polymer, Eudragit L100, were used as the inner/core liquid and outer/shell liquid in a coaxial electrospraying setup, respectively. As long as a sufficiently high voltage was applied, a stable Taylor cone-jet mode was obtained to produce very fine core-shell structure nanoparticles with high darunavir encapsulation efficiency of approximately 90%. The influence of the starting nanosuspension and the flow rates on the characteristics of the final electrosprayed particles was also evaluated. Using an optimized nanosuspension with reasonable size, size distribution and flow rates, the enteric coating layer reduced the percentage of DRV release in acidic medium in the in vitro dissolution test to ca. 20%. This study indicates that coaxial electrospraying is a potential and unique technique for encapsulating drug nanocrystals within a polymeric shell.

  15. Practical implications of some recent studies in electrospray ionization fundamentals.

    PubMed

    Cech, N B; Enke, C G

    2001-01-01

    In accomplishing successful electrospray ionization analyses, it is imperative to have an understanding of the effects of variables such as analyte structure, instrumental parameters, and solution composition. Here, we review some fundamental studies of the ESI process that are relevant to these issues. We discuss how analyte chargeability and surface activity are related to ESI response, and how accessible parameters such as nonpolar surface area and reversed phase HPLC retention time can be used to predict relative ESI response. Also presented is a description of how derivitizing agents can be used to maximize or enable ESI response by improving the chargeability or hydrophobicity of ESI analytes. Limiting factors in the ESI calibration curve are discussed. At high concentrations, these factors include droplet surface area and excess charge concentration, whereas at low concentrations ion transmission becomes an issue, and chemical interference can also be limiting. Stable and reproducible non-pneumatic ESI operation depends on the ability to balance a number of parameters, including applied voltage and solution surface tension, flow rate, and conductivity. We discuss how changing these parameters can shift the mode of ESI operation from stable to unstable, and how current-voltage curves can be used to characterize the mode of ESI operation. Finally, the characteristics of the ideal ESI solvent, including surface tension and conductivity requirements, are discussed. Analysis in the positive ion mode can be accomplished with acidified methanol/water solutions, but negative ion mode analysis necessitates special constituents that suppress corona discharge and facilitate the production of stable negative ions.

  16. Electrospray Collection of Lunar Dust

    NASA Technical Reports Server (NTRS)

    Dziekan, Michael

    2012-01-01

    A report describes ElectroSpray Ionization based Electrostatic Precipitation (ESIEP) for collecting lunar dust particles. While some HEPA filtration processes may remove a higher fraction (>99.9 percent) of the particles, the high efficiency may not be appropriate from an overall system standpoint, especially in light of the relatively large power requirement that such systems demand. The new electrospray particle capture technology is described as a variant of electrostatic precipitation that eliminates the current drawbacks of electrostatic precipitation. The new approach replaces corona prone field with a mist of highly charged micro-droplets generated by electrospray ionization (ESI) as the mechanism by which incoming particles are attracted and captured. In electrospray, a miniscule flow rate (microliters/minute) of liquid (typically water and a small amount of salt to enhance conductivity) is fed from the tip of a needle held at a high voltage potential relative to an opposite counter electrode. At sufficient field strength, a sharp liquid meniscus forms , which emits a jet of highly charged droplets that drift through the surrounding gas and are collected on the walls of a conductive tube. Particles in the gas have a high probability of contact with the droplets either by adhering to the droplets or otherwise acquiring a high level of charge, causing them to be captured on the collecting electrode as well. The spray acts as a filtration material that is continuously introduced and removed from the gas flow, and thus can never become clogged.

  17. Physical characteristics of faint meteors by light curve and high-resolution observations, and the implications for parent bodies

    NASA Astrophysics Data System (ADS)

    Subasinghe, Dilini; Campbell-Brown, Margaret D.; Stokan, Edward

    2016-04-01

    Optical observations of faint meteors (10-7 < mass < 10-4 kg) were collected by the Canadian Automated Meteor Observatory between 2010 April and 2014 May. These high-resolution (metre scale) observations were combined with two-station light-curve observations and the meteoroid orbit to classify meteors and attempt to answer questions related to meteoroid fragmentation, strength, and light-curve shape. The F parameter was used to classify the meteor light-curve shape; the observed morphology was used to classify the fragmentation mode; and the Tisserand parameter described the origin of the meteoroid. We find that most meteor light curves are symmetric (mean F parameter 0.49), show long distinct trails (continuous fragmentation), and are cometary in origin. Meteors that show no obvious fragmentation (presumably single body objects) show mostly symmetric light curves, surprisingly, and this indicates that light-curve shape is not an indication of fragility or fragmentation behaviour. Approximately 90 per cent of meteors observed with high-resolution video cameras show some form of fragmentation. Our results also show, unexpectedly, that meteors which show negligible fragmentation are more often on high-inclination orbits (i > 60°) than low-inclination ones. We also find that dynamically asteroidal meteors fragment as often as dynamically cometary meteors, which may suggest mixing in the early Solar system, or contamination between the dynamic groups.

  18. Salt Tolerance of Desorption Electrospray Ionization (DESI)

    SciTech Connect

    Jackson, Ayanna U.; Talaty, Nari; Cooks, R G; Van Berkel, Gary J

    2007-01-01

    Suppression of ion intensity in the presence of high salt matrices is common in most mass spectrometry ionization techniques. Desorption electrospray ionization (DESI) is an ionization method that exhibits salt tolerance, and this is investigated. DESI analysis was performed on three different drug mixtures in the presence of 0, 0.2, 2, 5, 10, and 20% NaCl:KCl weight by volume from seven different surfaces. At physiological concentrations individual drugs in each mixture were observed with each surface. Collision-induced dissociation (CID) was used to provide additional confirmation for select compounds. Multiple stage experiments, to MS5, were performed for select compounds. Even in the absence of added salt, the benzodiazepine containing mixture yielded sodium and potassium adducts of carbamazepine which masked the ions of interest. These adducts were eliminated by adding 0.1% 7M ammonium acetate to the standard methanol:water (1:1) spray solvent. Comparison of the salt tolerance of DESI with that of electrospray ionization (ESI) demonstrated much better signal/noise characteristics for DESI in this study. The salt tolerance of DESI was also studied by performing limit of detection and dynamic range experiments. Even at a salt concentration significantly above physiological concentrations, select surfaces were effective in providing spectra that allowed the ready identification of the compounds of interest. The already high salt tolerance of DESI can be optimized further by appropriate choices of surface and spray solution.

  19. Radial arrays of nano-electrospray ionization emitters and methods of forming electrosprays

    DOEpatents

    Kelly, Ryan T [West Richland, WA; Tang, Keqi [Richland, WA; Smith, Richard D [Richland, WA

    2010-10-19

    Electrospray ionization emitter arrays, as well as methods for forming electrosprays, are described. The arrays are characterized by a radial configuration of three or more nano-electrospray ionization emitters without an extractor electrode. The methods are characterized by distributing fluid flow of the liquid sample among three or more nano-electrospray ionization emitters, forming an electrospray at outlets of the emitters without utilizing an extractor electrode, and directing the electrosprays into an entrance to a mass spectrometry device. Each of the nano-electrospray ionization emitters can have a discrete channel for fluid flow. The nano-electrospray ionization emitters are circularly arranged such that each is shielded substantially equally from an electrospray-inducing electric field.

  20. Estimated bankfull discharge for selected Michigan rivers and regional hydraulic geometry curves for estimating bankfull characteristics in southern Michigan rivers

    USGS Publications Warehouse

    Rachol, Cynthia M.; Boley-Morse, Kristine

    2009-01-01

    Regional hydraulic geometry curves are power-function equations that relate riffle dimensions and bankfull discharge to drainage-basin size. They are defined by data collected through surveys conducted at stable stream reaches and can be used to aid watershed managers, design engineers, and others involved in determination of the best course of action for an unstable stream. Hydraulic geometry curves provide a mechanism through which comparisons can be made between riffle dimensions collected at an unstable stream to those collected at stable streams within the same region. In 2005, a study was initiated to delineate regional hydraulic geometry curves for Michigan. After in-office review of 343 U.S. Geological Survey streamgaging stations and an extensive field reconnaissance effort, 44 stable reaches were selected for this study. Detailed surveys that included cross-sectional and longitudinal profiles and pebble counts were conducted at selected streamgages, which were distributed throughout Michigan. By use of survey data from riffle cross sections and water-surface slope, bankfull discharge was estimated and compared to flood-recurrence intervals using regional flood equations. This comparison shows that bankfull discharges in Michigan recur more frequently than every 2 years. Regional hydraulic geometry curves were developed rather than statewide curves owing to large differences in factors that control channel geometry across the State. However, after the data were subdivided according to ecoregions, it was determined that there were enough data to delineate regional hydraulic geometry curves only for the Southern Lower Michigan Ecoregion. For this ecoregion, geometry curve equations and their coefficients of determination are: Width = 8.19 x DA0.44; R2 = 0.69, Depth = 0.67 x DA0.27; R2 = 0.28, Area = 4.38 x DA0.74; R2 = 0.59, where DA is the drainage area and R2 is the coefficient of determination. By use of discharge estimates for the Southern Lower Michigan

  1. 7 CFR 42.141 - Obtaining Operating Characteristic (OC) curve information for skip lot sampling and inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... Then refer to the graph in § 42.142 and locate Pa of 95 percent along the horizontal axis. From this point, proceed vertically to the curve and then horizontally to the left to the vertical axis. From this point on the vertical axis, Pas is determined to be approximately 98 1 percent for skip lot sampling...

  2. Digital electrospray for controlled deposition.

    PubMed

    Deng, Weiwei; Waits, C Mike; Gomez, Alessandro

    2010-03-01

    Many novel functional structures are now fabricated by controlled deposition as a maskless, bottom-up fabrication technique. These applications require rapid and precise deposition of minute amounts of solutions/suspensions or their ultimate particle products in predefined patterns. The electrospray is a promising alternative to the commonly used inkjet printing because it can easily handle highly viscous liquid, avoid high shear rates, and has low risk of clogging. We demonstrate a proof-of-concept digital electrospray. This system consists of a 61-nozzle array microfabricated in silicon and a 61-element digital extractor fabricated using flexible polyimide substrates. "Digital" refers to the state of each electrospray source that can be tuned either on or off independently and responsively. We showed a resolution of 675 mum and a response frequency up to 100 Hz. With similar design and industry standard fabrication procedures, it is feasible to scale up the system to O(1000) sources with spatial resolution better than 250 mum and a O(kHz) response frequency. The latter is controlled by the viscous damping time.

  3. Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: Results from independently conducted FROC/ROC studies in mammography

    SciTech Connect

    Zanca, Federica; Hillis, Stephen L.; Claus, Filip; Van Ongeval, Chantal; Celis, Valerie; Provoost, Veerle; Yoon, Hong-Jun; Bosmans, Hilde

    2012-10-15

    Purpose: From independently conducted free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) experiments, to study fixed-reader associations between three estimators: the area under the alternative FROC (AFROC) curve computed from FROC data, the area under the ROC curve computed from FROC highest rating data, and the area under the ROC curve computed from confidence-of-disease ratings. Methods: Two hundred mammograms, 100 of which were abnormal, were processed by two image-processing algorithms and interpreted by four radiologists under the FROC paradigm. From the FROC data, inferred-ROC data were derived, using the highest rating assumption. Eighteen months afterwards, the images were interpreted by the same radiologists under the conventional ROC paradigm; conventional-ROC data (in contrast to inferred-ROC data) were obtained. FROC and ROC (inferred, conventional) data were analyzed using the nonparametric area-under-the-curve (AUC), (AFROC and ROC curve, respectively). Pearson correlation was used to quantify the degree of association between the modality-specific AUC indices and standard errors were computed using the bootstrap-after-bootstrap method. The magnitude of the correlations was assessed by comparison with computed Obuchowski-Rockette fixed reader correlations. Results: Average Pearson correlations (with 95% confidence intervals in square brackets) were: Corr(FROC, inferred ROC) = 0.76[0.64, 0.84] > Corr(inferred ROC, conventional ROC) = 0.40[0.18, 0.58] > Corr (FROC, conventional ROC) = 0.32[0.16, 0.46]. Conclusions: Correlation between FROC and inferred-ROC data AUC estimates was high. Correlation between inferred- and conventional-ROC AUC was similar to the correlation between two modalities for a single reader using one estimation method, suggesting that the highest rating assumption might be questionable.

  4. Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: Results from independently conducted FROC/ROC studies in mammography

    PubMed Central

    Zanca, Federica; Hillis, Stephen L.; Claus, Filip; Van Ongeval, Chantal; Celis, Valerie; Provoost, Veerle; Yoon, Hong-Jun; Bosmans, Hilde

    2012-01-01

    Purpose: From independently conducted free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) experiments, to study fixed-reader associations between three estimators: the area under the alternative FROC (AFROC) curve computed from FROC data, the area under the ROC curve computed from FROC highest rating data, and the area under the ROC curve computed from confidence-of-disease ratings. Methods: Two hundred mammograms, 100 of which were abnormal, were processed by two image-processing algorithms and interpreted by four radiologists under the FROC paradigm. From the FROC data, inferred-ROC data were derived, using the highest rating assumption. Eighteen months afterwards, the images were interpreted by the same radiologists under the conventional ROC paradigm; conventional-ROC data (in contrast to inferred-ROC data) were obtained. FROC and ROC (inferred, conventional) data were analyzed using the nonparametric area-under-the-curve (AUC), (AFROC and ROC curve, respectively). Pearson correlation was used to quantify the degree of association between the modality-specific AUC indices and standard errors were computed using the bootstrap-after-bootstrap method. The magnitude of the correlations was assessed by comparison with computed Obuchowski-Rockette fixed reader correlations. Results: Average Pearson correlations (with 95% confidence intervals in square brackets) were: Corr(FROC, inferred ROC) = 0.76[0.64, 0.84] > Corr(inferred ROC, conventional ROC) = 0.40[0.18, 0.58] > Corr (FROC, conventional ROC) = 0.32[0.16, 0.46]. Conclusions: Correlation between FROC and inferred-ROC data AUC estimates was high. Correlation between inferred- and conventional-ROC AUC was similar to the correlation between two modalities for a single reader using one estimation method, suggesting that the highest rating assumption might be questionable. PMID:23039631

  5. Development of Web-based Load Duration Curve system for analysis of total maximum daily load and water quality characteristics in a waterbody.

    PubMed

    Kim, Jonggun; Engel, Bernard A; Park, Youn Shik; Theller, Larry; Chaubey, Indrajeet; Kong, Dong Soo; Lim, Kyoung Jae

    2012-04-30

    In many states of the US, the total maximum daily load program has been widely developed for watershed water quality restoration and management. However, the total maximum daily load is often represented as an average daily pollutant load based on average long-term flow conditions, and as such, it does not adequately describe the problems they aim to address. Without an adequate characterization of water quality problems, appropriate solutions cannot be identified and implemented. The total maximum daily load approach should consider adequate water quality characterizations based on overall flow conditions rather than on a single flow event such as average daily flow. The Load Duration Curve, which provides opportunities for enhanced pollutant source and best management practice targeting both in the total maximum daily load development and in water quality restoration efforts, has been used for the determination of appropriate total maximum daily load targets. However, at least 30 min to an hour is needed for unskilled people based on our experiences to generate the Load Duration Curve using a desktop-based spreadsheet computer program. Therefore, in this study, the Web-based Load Duration Curve system (https://engineering.purdue.edu/∼ldc/) was developed and applied to a study watershed for an analysis of the total maximum daily load and water quality characteristics in the watershed. This system provides diverse options for Flow Duration Curve and Load Duration Curve analysis of a watershed of interest in a brief time. The Web-based Load Duration Curve system is useful for characterizing the problem according to flow regimes, and for providing a visual representation that enables an easy understanding of the problem and the total maximum daily load targets. In addition, this system will be able to help researchers identify appropriate best management practices within watersheds.

  6. Investigation of the ionisation density dependence of the glow curve characteristics of LIF:MG,TI (TLD-100)

    PubMed Central

    Horowitz, Y. S.; Horowitz, A.; Oster, L.; Marino, S.; Datz, H.; Margaliot, M.

    2008-01-01

    The dependence of the shape of the glow curve of LiF:Mg,Ti (TLD-100) on ionisation density was investigated using irradiation with 90Sr/90Y beta rays, 60 and 250 kVp X rays, various heavy-charged particles and 0.2 and 14 MeV neutrons. Special attention is focused on the properties of high-temperature thermoluminescence; specifically, the behaviour of the high-temperature ratio (HTR) of Peaks 7 and 8 as a function of batch and annealing protocol. The correlation of Peaks 7 and 8 with average linear-energy-transfer (LET) is also investigated. The HTR of Peak 7 is found to be independent of LET for values of LET approximately >30 keV µm−1. The behaviour of the HTR of Peak 8 with LET is observed to be erratic, which suggests that applications using the HTR should separate the contributions of Peaks 7 and 8 using computerised glow curve deconvolution. The behaviour of the HTR following neutron irradiation is complex and not fully understood. The shape of composite Peak 5 is observed to be broader following high ionisation alpha particle irradiation, suggesting that the combined use of the HTR and the shape of Peak 5 could lead to improved ionisation density discrimination for particles of high LET. PMID:18667402

  7. Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis

    PubMed Central

    Jaime-Pérez, José Carlos; García-Arellano, Gisela; Méndez-Ramírez, Nereida; González-Llano, Óscar; Gómez-Almaguer, David

    2015-01-01

    Objective By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test probability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. Methods Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 μg/L in women and a cord blood serum ferritin <35.0 μg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. Results The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 μg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). Conclusion Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns. PMID:26041420

  8. Receiver operating characteristic (ROC) curve for classification of 18F-NaF uptake on PET/CT*

    PubMed Central

    Valadares, Agnes Araujo; Duarte, Paulo Schiavom; Carvalho, Giovanna; Ono, Carla Rachel; Coura-Filho, George Barberio; Sado, Heitor Naoki; Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto

    2016-01-01

    Objective To assess the cutoff values established by ROC curves to classify 18F-NaF uptake as normal or malignant. Materials and Methods PET/CT images were acquired 1 hour after administration of 185 MBq of 18F-NaF. Volumes of interest (VOIs) were drawn on three regions of the skeleton as follows: proximal right humerus diaphysis (HD), proximal right femoral diaphysis (FD) and first vertebral body (VB1), in a total of 254 patients, totalling 762 VOIs. The uptake in the VOIs was classified as normal or malignant on the basis of the radiopharmaceutical distribution pattern and of the CT images. A total of 675 volumes were classified as normal and 52 were classified as malignant. Thirty-five VOIs classified as indeterminate or nonmalignant lesions were excluded from analysis. The standardized uptake value (SUV) measured on the VOIs were plotted on an ROC curve for each one of the three regions. The area under the ROC (AUC) as well as the best cutoff SUVs to classify the VOIs were calculated. The best cutoff values were established as the ones with higher result of the sum of sensitivity and specificity. Results The AUCs were 0.933, 0.889 and 0.975 for UD, FD and VB1, respectively. The best SUV cutoffs were 9.0 (sensitivity: 73%; specificity: 99%), 8.4 (sensitivity: 79%; specificity: 94%) and 21.0 (sensitivity: 93%; specificity: 95%) for UD, FD and VB1, respectively. Conclusion The best cutoff value varies according to bone region of analysis and it is not possible to establish one value for the whole body. PMID:26929455

  9. Confidence Intervals for the Probability of Superiority Effect Size Measure and the Area under a Receiver Operating Characteristic Curve

    ERIC Educational Resources Information Center

    Ruscio, John; Mullen, Tara

    2012-01-01

    It is good scientific practice to the report an appropriate estimate of effect size and a confidence interval (CI) to indicate the precision with which a population effect was estimated. For comparisons of 2 independent groups, a probability-based effect size estimator (A) that is equal to the area under a receiver operating characteristic curve…

  10. Analysis of DSC thermal curves for assigning a characteristic glass transition temperature, dependent on either the type or thermal history of the polymer

    SciTech Connect

    Saffell, J.R.

    1994-09-01

    DSC was used to study the thermal curve characteristics of four classical polymer glasses: polycarbonate (PC), anionic polystyrene (aPS), polysulfone, and polymethyl methacrylate (PMMA). The onset, peak, and fictive temperatures as well as endotherm characteristics were studied over two decades of heating and cooling rates. Assuming that the fictive temperature is independent of heating rate, the usefulness of T{sub onset} and ambiguity of T{sub peak} are demonstrated. The useful [heat/cool] ratio allows use of T{sub onset} to calculate the effective cooling rate of the sample (which is easier to calculate than T{sub fictive}). Comparison with results from annealed samples are shown. The fictive and onset temperatures can be used together to improve the reliability of glass temperature characterization and results are surprisingly constant between the four different types of glasses, leading to a method of providing a single temperature to characterize the thermal history/morphology using a DSC thermal curve. The peak temperature is nearly independent of thermal history, and so provides a characterization parameter that is insensitive to manufacturing and molding procedures.

  11. Electrospray Ionization on Solid Substrates

    PubMed Central

    So, Pui-Kin; Hu, Bin; Yao, Zhong-Ping

    2014-01-01

    Development of electrospray ionization on solid substrates (solid-substrate ESI) avoids the clogging problem encountered in conventional capillary-based ESI, allows more convenient sampling and permits new applications. So far, solid-substrate ESI with various materials, e.g., metals, paper, wood, fibers and biological tissue, has been developed, and applications ranging from analysis of pure compounds to complex mixtures as well as in vivo study were demonstrated. Particularly, the capability of solid-substrate ESI in direct analysis of complex samples, e.g., biological fluids and foods, has significantly facilitated mass spectrometric analysis in real-life applications and led to increasingly important roles of these techniques nowadays. In this review, various solid-substrate ESI techniques and their applications are summarized and the prospects in this field are discussed. PMID:26819900

  12. Thin-channel electrospray emitter

    DOEpatents

    Van Berkel, Gary J.

    2004-08-31

    An electrospray device includes a high voltage electrode chamber. The high voltage electrode chamber includes an inlet for receiving a fluid to be ionized and for directing the fluid into the chamber and at least one electrode having an exposed surface within the chamber. A flow channel directs fluid over a surface of the electrode and out of the chamber. The length of the flow channel over the electrode is greater than the height of the flow channel over the electrode, thereby producing enhanced mass transport to the working electrode resulting in improved electrolysis efficiency. An outlet is provided for transmitting the fluid out from the electrode chamber. A method of creating charged droplets includes flowing a fluid over an electrode where the length over the electrode is greater than the height of the fluid flowing over the electrode.

  13. Remote mass spectrometric sampling of electrospray- and desorption electrospray-generated ions using an air ejector.

    PubMed

    Dixon, R Brent; Bereman, Michael S; Muddiman, David C; Hawkridge, Adam M

    2007-10-01

    A commercial air ejector was coupled to an electrospray ionization linear ion trap mass spectrometer (LTQ) to transport remotely generated ions from both electrospray (ESI) and desorption electrospray ionization (DESI) sources. We demonstrate the remote analysis of a series of analyte ions that range from small molecules and polymers to polypeptides using the AE-LTQ interface. The details of the ESI-AE-LTQ and DESI-AE-LTQ experimental configurations are described and preliminary mass spectrometric data are presented.

  14. Flow-duration curves

    USGS Publications Warehouse

    Searcy, James Kincheon

    1959-01-01

    The flow-duration curve is a cumulative frequency curve that shows the percent of time specified discharges were equaled or exceeded during a given period. It combines in one curve the flow characteristics of a stream throughout the range of discharge, without regard to the sequence of occurrence. If the period upon which the curve is based represents the long-term flow of a stream, the curve may be used to predict the distribution of future flows for water- power, water-supply, and pollution studies. This report shows that differences in geology affect the low-flow ends of flow-duration curves of streams in adjacent basins. Thus, duration curves are useful in appraising the geologic characteristics of drainage basins. A method for adjusting flow-duration curves of short periods to represent long-term conditions is presented. The adjustment is made by correlating the records of a short-term station with those of a long-term station.

  15. Electrospray ion source with reduced analyte electrochemistry

    DOEpatents

    Kertesz, Vilmos [Knoxville, TN; Van Berkel, Gary [Clinton, TN

    2011-08-23

    An electrospray ion (ESI) source and method capable of ionizing an analyte molecule without oxidizing or reducing the analyte of interest. The ESI source can include an emitter having a liquid conduit, a working electrode having a liquid contacting surface, a spray tip, a secondary working electrode, and a charge storage coating covering partially or fully the liquid contacting surface of the working electrode. The liquid conduit, the working electrode and the secondary working electrode can be in liquid communication. The electrospray ion source can also include a counter electrode proximate to, but separated from, said spray tip. The electrospray ion source can also include a power system for applying a voltage difference between the working electrodes and a counter-electrode. The power system can deliver pulsed voltage changes to the working electrodes during operation of said electrospray ion source to minimize the surface potential of the charge storage coating.

  16. Statistical evidences of seismo-ionospheric precursors applying receiver operating characteristic (ROC) curve on the GPS total electron content in China

    NASA Astrophysics Data System (ADS)

    Chen, Yuh-Ing; Huang, Chi-Shen; Liu, Jann-Yenq

    2015-12-01

    Evidence of the seismo-ionospheric precursor (SIP) is reported by statistically investigating the relationship between the total electron content (TEC) in global ionosphere map (GIM) and 56 M ⩾ 6.0 earthquakes during 1998-2013 in China. A median-based method together with the z test is employed to examine the TEC variations 30 days before and after the earthquake. It is found that the TEC significantly decreases 0600-1000 LT 1-6 days before the earthquake, and anomalously increases in 3 time periods of 1300-1700 LT 12-15 days; 0000-0500 LT 15-17 days; and 0500-0900 LT 22-28 days before the earthquake. The receiver operating characteristic (ROC) curve is then used to evaluate the efficiency of TEC for predicting M ⩾ 6.0 earthquakes in China during a specified time period. Statistical results suggest that the SIP is the significant TEC reduction in the morning period of 0600-1000 LT. The SIP is further confirmed since the area under the ROC curve is positively associated with the earthquake magnitude.

  17. Experimental and theoretical investigation of the rocking curves measured for MoK{sub α} X-ray characteristic lines in the double-crystal nondispersive scheme

    SciTech Connect

    Marchenkov, N. V. Chukhovskii, F. N.; Blagov, A. E.

    2015-03-15

    The rocking curves (RCs) for MoK{sub α1} and MoK{sub α2} characteristic X-ray lines have been experimentally and theoretically studied in the nondispersive scheme of an X-ray double-crystal TPC-K diffractometer. The results of measurements and theoretical calculations of double-crystal RCs for characteristic X-rays from tubes with a molybdenum anode and different widths of slits show that a decrease in the slit width leads to an increase in the relative contribution of the MoK{sub α2}-line RC in comparison with the intensity of the tails of the MoK{sub α1}-line RC. It is shown that the second peak of the MoK{sub α2} line becomes increasingly pronounced in the tail of the MoK{sub α1}-line RC with a decrease in the slit width. Two plane-parallel Si plates (input faces (110), diffraction vector h 〈220〉) were used as a monochromator crystal and a sample. The results of measuring double-crystal RCs are in good agreement with theoretical calculations.

  18. Charge emissions from electrosprays in vacuum: Mixtures of formamide with methylammonium formate

    NASA Astrophysics Data System (ADS)

    Garoz, David; Fernández de la Mora, Juan

    2013-02-01

    The charge/mass distribution f(q/m) of nanodrops and ions electrosprayed in vacuum from mixtures of formamide (FM) and methylammonium formate (MAF) is studied by time of flight mass spectrometry at MAF/FM volumetric concentrations of 5%, 10%, 25%, and 50%. Positive and negative polarities yield comparable f(q/m) curves, though the negative mode yields ˜30% larger currents. On shifting from the highest to the lowest liquid flow rates at which a cone-jet is stable, the more conductive solutions evolve from mostly drop to primarily ion emission. A purely ionic regime is not reached under any condition, but the drops achieve unusually high q/m. As a result, these sprays have excellent electrical propulsion characteristics, some being able to cover a 25-fold range of average q/m with a polydispersive efficiency typically in the range of 80%. Results of formamide electrolytes with formates and nitrates of several other amines are more briefly reported.

  19. Task-based detectability comparison of exponential transformation of free-response operating characteristic (EFROC) curve and channelized Hotelling observer (CHO)

    NASA Astrophysics Data System (ADS)

    Khobragade, P.; Fan, Jiahua; Rupcich, Franco; Crotty, Dominic J.; Gilat Schmidt, Taly

    2016-03-01

    This study quantitatively evaluated the performance of the exponential transformation of the free-response operating characteristic curve (EFROC) metric, with the Channelized Hotelling Observer (CHO) as a reference. The CHO has been used for image quality assessment of reconstruction algorithms and imaging systems and often it is applied to study the signal-location-known cases. The CHO also requires a large set of images to estimate the covariance matrix. In terms of clinical applications, this assumption and requirement may be unrealistic. The newly developed location-unknown EFROC detectability metric is estimated from the confidence scores reported by a model observer. Unlike the CHO, EFROC does not require a channelization step and is a non-parametric detectability metric. There are few quantitative studies available on application of the EFROC metric, most of which are based on simulation data. This study investigated the EFROC metric using experimental CT data. A phantom with four low contrast objects: 3mm (14 HU), 5mm (7HU), 7mm (5 HU) and 10 mm (3 HU) was scanned at dose levels ranging from 25 mAs to 270 mAs and reconstructed using filtered backprojection. The area under the curve values for CHO (AUC) and EFROC (AFE) were plotted with respect to different dose levels. The number of images required to estimate the non-parametric AFE metric was calculated for varying tasks and found to be less than the number of images required for parametric CHO estimation. The AFE metric was found to be more sensitive to changes in dose than the CHO metric. This increased sensitivity and the assumption of unknown signal location may be useful for investigating and optimizing CT imaging methods. Future work is required to validate the AFE metric against human observers.

  20. Growth curves and age-related changes in carcass characteristics, organs, serum parameters, and intestinal transporter gene expression in domestic pigeon (Columba livia).

    PubMed

    Gao, C Q; Yang, J X; Chen, M X; Yan, H C; Wang, X Q

    2016-04-01

    Two experiments were conducted to fit growth curves, and determine age-related changes in carcass characteristics, organs, serum biochemical parameters, and gene expression of intestinal nutrient transporters in domestic pigeon (Columba livia). In experiment 1, body weight (BW) of 30 pigeons was respectively determined at 1, 3, 7, 14, 21, 28, and 35 days old to fit growth curves and to describe the growth of pigeons. In experiment 2, eighty-four 1-day-old squabs were grouped by weight into 7 groups. On d 1, 3, 7, 14, 21, 28, and 35, twelve birds from each group were randomly selected for slaughter and post-slaughter analysis. The results showed that BW of pigeons increased rapidly from d 1 to d 28 (a 25.7-fold increase), and then had little change until d 35. The Logistic, Gompertz, and Von Bertalanffy functions can all be well fitted with the growth curve of domestic pigeons (R2>0.90) and the Gompertz model showed the highest R2value among the models (R2=0.9997). The equation of Gompertz model was Y=507.72×e-(3.76exp(-0.17t))(Y=BW of pigeon (g); t=time (day)). In addition, breast meat yield (%) increased with age throughout the experiment, whereas the leg meat yield (%) reached to the peak on d 14. Serum total protein, albumin, globulin, and glucose concentration were increased with age, whereas serum uric acid concentration was decreased (P<0.05). Furthermore, the gene expressions of nutrient transporters (y+LAT2, LAT1, B0AT1, PepT1, and NHE2) in jejunum of pigeon were increased with age. The results of correlation analysis showed the gene expressions of B0AT1, PepT1, and NHE2 had positive correlations with BW (0.73

  1. Production and properties of electrosprayed sericin nanopowder

    NASA Astrophysics Data System (ADS)

    Hazeri, Najmeh; Tavanai, Hossein; Moradi, Ali Reza

    2012-06-01

    Sericin is a proteinous substrate that envelops fibroin (silk) fiber, and its recovery provides significant economical and social benefits. Sericin is an antibacterial agent that resists oxidation and absorbs moisture and UV light. In powder form, sericin has a wide range of applications in food, cosmetics and drug delivery. Asides from other techniques of producing powder, such as precipitation and spray drying, electrospraying can yield solid nanoparticles, particularly in the submicron range. Here, we report the production of sericin nanopowder by electrospraying. Sericin sponge was recovered from Bombyx mori cocoons through a high-temperature, high-pressure process, followed by centrifugation and freeze drying of the sericin solution. The electrospraying solution was prepared by dissolving the sericin sponge in dimethyl sulfoxide. We demonstrate that electrospraying is capable of producing sericin nanopowder with an average particle size of 25 nm, which is by far smaller than the particles produced by other techniques. The electrosprayed sericin nanopowder consists of small crystallites and exhibits a high moisture absorbance.

  2. Highly curved microchannel plates

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Cully, S.; Warren, J.; Gaines, G. A.; Priedhorsky, W.; Bloch, J.

    1990-01-01

    Several spherically curved microchannel plate (MCP) stack configurations were studied as part of an ongoing astrophysical detector development program, and as part of the development of the ALEXIS satellite payload. MCP pairs with surface radii of curvature as small as 7 cm, and diameters up to 46 mm have been evaluated. The experiments show that the gain (greater than 1.5 x 10 exp 7) and background characteristics (about 0.5 events/sq cm per sec) of highly curved MCP stacks are in general equivalent to the performance achieved with flat MCP stacks of similar configuration. However, gain variations across the curved MCP's due to variations in the channel length to diameter ratio are observed. The overall pulse height distribution of a highly curved surface MCP stack (greater than 50 percent FWHM) is thus broader than its flat counterpart (less than 30 percent). Preconditioning of curved MCP stacks gives comparable results to flat MCP stacks, but it also decreases the overall gain variations. Flat fields of curved MCP stacks have the same general characteristics as flat MCP stacks.

  3. Bradford Curves.

    ERIC Educational Resources Information Center

    Rousseau, Ronald

    1994-01-01

    Discussion of informetric distributions shows that generalized Leimkuhler functions give proper fits to a large variety of Bradford curves, including those exhibiting a Groos droop or a rising tail. The Kolmogorov-Smirnov test is used to test goodness of fit, and least-square fits are compared with Egghe's method. (Contains 53 references.) (LRW)

  4. Capillary electrophoresis electrospray ionization mass spectrometry interface

    DOEpatents

    Smith, Richard D.; Severs, Joanne C.

    1999-01-01

    The present invention is an interface between a capillary electrophoresis separation capillary end and an electrospray ionization mass spectrometry emitter capillary end, for transporting an anolyte sample from a capillary electrophoresis separation capillary to a electrospray ionization mass spectrometry emitter capillary. The interface of the present invention has: (a) a charge transfer fitting enclosing both of the capillary electrophoresis capillary end and the electrospray ionization mass spectrometry emitter capillary end; (b) a reservoir containing an electrolyte surrounding the charge transfer fitting; and (c) an electrode immersed into the electrolyte, the electrode closing a capillary electrophoresis circuit and providing charge transfer across the charge transfer fitting while avoiding substantial bulk fluid transfer across the charge transfer fitting. Advantages of the present invention have been demonstrated as effective in providing high sensitivity and efficient analyses.

  5. Bacterial Spores Survive Electrospray Charging and Desolvation

    NASA Astrophysics Data System (ADS)

    Pratt, Sara N.; Austin, Daniel E.

    2014-05-01

    The survivability of Bacillus subtilis spores and vegetative Escherichia coli cells after electrospray from aqueous suspension was tested using mobility experiments at atmospheric pressure. E. coli did not survive electrospray charging and desolvation, but B. subtilis did. Experimental conditions ensured that any surviving bacteria were de-agglomerated, desolvated, and electrically charged. Based on mobility measurements, B. subtilis spores survived even with 2,000-20,000 positive charges. B. subtilis was also found to survive introduction into vacuum after either positive or negative electrospray. Attempts to measure the charge distribution of viable B. subtilis spores using electrostatic deflection in vacuum were inconclusive; however, viable spores with low charge states (less than 42 positive or less than 26 negative charges) were observed.

  6. Impact of molecular weight on the formation of electrosprayed chitosan microcapsules as delivery vehicles for bioactive compounds.

    PubMed

    Gómez-Mascaraque, Laura G; Sanchez, Gloria; López-Rubio, Amparo

    2016-10-05

    The molecular weight of chitosan is one of its most determinant characteristics, which affects its processability and its performance as a biomaterial. However, information about the effect of this parameter on the formation of electrosprayed chitosan microcapsules is scarce. In this work, the impact of chitosan molecular weight on its electrosprayability was studied and correlated with its effect on the viscosity, surface tension and electrical conductivity of solutions. A Discriminant Function Analysis revealed that the morphology of the electrosprayed chitosan materials could be correctly predicted using these three parameters for almost 85% of the samples. The suitability of using electrosprayed chitosan capsules as carriers for bioactive agents was also assessed by loading them with a model active compound, (-)-epigallocatechin gallate (EGCG). This encapsulation, with an estimated efficiency of around 80% in terms of preserved antioxidant activity, showed the potential to prolong the antiviral activity of EGCG against murine norovirus via gradual bioactive release combined with its protection against degradation in simulated physiological conditions.

  7. Surface tension effects on submerged electrosprays

    PubMed Central

    Marín, Álvaro G.; Loscertales, Ignacio G.; Barrero, Antonio

    2012-01-01

    Electrosprays are a powerful technique to generate charged micro/nanodroplets. In the last century, the technique has been extensively studied, developed, and recognized with a shared Nobel price in Chemistry in 2002 for its wide spread application in mass spectrometry. However, nowadays techniques based on microfluidic devices are competing to be the next generation in atomization techniques. Therefore, an interesting development would be to integrate the electrospray technique into a microfluidic liquid-liquid device. Several works in the literature have attempted to build a microfluidic electrospray with disputable results. The main problem for its integration is the lack of knowledge of the working parameters of the liquid-liquid electrospray. The “submerged electrosprays” share similar properties as their counterparts in air. However, in the microfluidic generation of micro/nanodroplets, the liquid-liquid interfaces are normally stabilized with surface active agents, which might have critical effects on the electrospray behavior. In this work, we review the main properties of the submerged electrosprays in liquid baths with no surfactant, and we methodically study the behavior of the system for increasing surfactant concentrations. The different regimes found are then analyzed and compared with both classical and more recent experimental, theoretical and numerical studies. A very rich phenomenology is found when the surface tension is allowed to vary in the system. More concretely, the lower states of electrification achieved with the reduced surface tension regimes might be of interest in biological or biomedical applications in which excessive electrification can be hazardous for the encapsulated entities. PMID:24155865

  8. Evaluation of formulae for CSF IgG synthesis using data obtained from two methods: importance of receiver operator characteristic curve analysis.

    PubMed Central

    McMillan, S A; Douglas, J P; Droogan, A G; Hawkins, S A

    1996-01-01

    AIMS: To determine the clinical performance of three cerebrospinal fluid (CSF) IgG synthesis formulae using data obtained from two quantitation methods. METHODS: Receiver operator characteristic (ROC) analysis and decision index plots were used to compare a rate nephelometric (RN) and a rocket immunoelectrophoretic (RIEP) method for quantitating albumin and IgG for use in CSF IgG synthesis formulae. Further analysis was used to determine the most clinically accurate of these formulae for a diagnosis of multiple sclerosis with regard to technical accuracy and cost effectiveness. RESULTS: Values for albumin and IgG determined by RN gave better sensitivities and specificities than the RIEP method when applied to all three formulae; however, when the 95% confidence limits were considered, the difference was not significant. Using the RN method with an agreed "rule in" threshold value of 90% specificity, the IgG index gave the best clinical performance. CONCLUSION: ROC curve analysis and decision index plots provide valuable tools in assessing and comparing the clinical performance of new and existing laboratory assays. PMID:8666680

  9. Perspective Biological Markers for Autism Spectrum Disorders: Advantages of the Use of Receiver Operating Characteristic Curves in Evaluating Marker Sensitivity and Specificity

    PubMed Central

    2015-01-01

    Autism Spectrum Disorders (ASD) are a heterogeneous group of neurodevelopmental disorders. Recognized causes of ASD include genetic factors, metabolic diseases, toxic and environmental factors, and a combination of these. Available tests fail to recognize genetic abnormalities in about 70% of ASD children, where diagnosis is solely based on behavioral signs and symptoms, which are difficult to evaluate in very young children. Although it is advisable that specific psychotherapeutic and pedagogic interventions are initiated as early as possible, early diagnosis is hampered by the lack of nongenetic specific biological markers. In the past ten years, the scientific literature has reported dozens of neurophysiological and biochemical alterations in ASD children; however no real biomarker has emerged. Such literature is here reviewed in the light of Receiver Operating Characteristic (ROC) analysis, a very valuable statistical tool, which evaluates the sensitivity and the specificity of biomarkers to be used in diagnostic decision making. We also apply ROC analysis to some of our previously published data and discuss the increased diagnostic value of combining more variables in one ROC curve analysis. We also discuss the use of biomarkers as a tool for advancing our understanding of nonsyndromic ASD. PMID:26648598

  10. Electrosprayed TiO2 nanoporous hemispheres for enhanced electron transport and device performance of formamidinium based perovskite solar cells.

    PubMed

    Ye, Tao; Ma, Shaoyang; Jiang, Xi; Petrović, Miloš; Vijila, Chellappan; Ramakrishna, Seeram; Wei, Lei

    2017-01-07

    Titanium dioxide (TiO2) nanoporous hemispheres (NHSs) with a radius of ∼200 nm are fabricated by electrospraying a hydrothermally synthesized TiO2 nanoparticle (NP) suspension solution. The resulting TiO2 NHSs are highly porous, which are beneficial to the infiltration of perovskites and provide a larger contact area, as building blocks to construct a mesoporous TiO2 layer for FA0.81MA0.15Pb(I0.836Br0.15)3 based perovskite solar cells (PSCs). By varying the TiO2 NHS collecting period (15 s, 30 s, 60 s and 90 s) during the electrospraying process, the performance of PSCs changes with different TiO2 NHS distribution densities. The optimized PSC employing TiO2 NHSs (60 s) exhibits a photovoltaic conversion efficiency (PCE) as high as 19.3% with a Jsc of 23.8 mA cm(-2), a Voc of 1.14 V and a FF of 0.71. Furthermore, the PSC possesses a reproducible PCE value with little hysteresis in its current density-voltage (J-V) curves. The small perturbation transient photovoltage (TPV) measurement reveals a longer free carrier lifetime within the TiO2 NHS based PSC than that in the TiO2 NP based PSC, and the time of flight (TOF) photoconductivity measurement shows that charge mobilities in this system are also enhanced. These characteristics make TiO2 NHSs a promising electron transport material for efficient photovoltaic devices.

  11. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard D.; Udseth, Harold R.; Barinaga, Charles J.

    1995-01-01

    An improvement to the system and method for analyzing molecular constituents of a composition sample that comprises improvements to an electrospray ionization source for interfacing to mass spectrometers and other detection devices. The improvement consists of establishing a unique electrical circuit pattern and nozzle configuration, a metallic coated and conical shaped capillary outlet, coupled with sizing of the capillary to obtain maximum sensitivity.

  12. Dynamics of curved interfaces

    SciTech Connect

    Escudero, Carlos

    2009-08-15

    Stochastic growth phenomena on curved interfaces are studied by means of stochastic partial differential equations. These are derived as counterparts of linear planar equations on a curved geometry after a reparametrization invariance principle has been applied. We examine differences and similarities with the classical planar equations. Some characteristic features are the loss of correlation through time and a particular behavior of the average fluctuations. Dependence on the metric is also explored. The diffusive model that propagates correlations ballistically in the planar situation is particularly interesting, as this propagation becomes nonuniversal in the new regime.

  13. Flow Interface for Charge Reduced Electrospray of Nanoparticle Solutions

    PubMed Central

    Adou, Kouame; Johnston, Murray V.

    2009-01-01

    A charge reduction (CR) interface for electrospray ionization was characterized that permits simultaneous analysis of nanoparticle solutions by multiple detection methods. In the direct infusion configuration, a constant flow of analyte solution undergoes electrospray ionization (ESI). The charged aerosol is sampled directly into the atmospheric pressure inlet of a quadrupole time-of-flight mass spectrometer (QTOF) and to a CR device followed by a differential mobility analyzer (DMA) and condensation particle counter (CPC). In the plug injection configuration, analyte solution is injected into a liquid chromatograph. The effluent is split to an evaporative light scattering detector (ELSD) and the ESI interface. The charged aerosol is then sampled through the CR device directly into the CPC. Performance characteristics of the two configurations were studied with sucrose and protein solutions. When a liquid flow rate in the low µL/min range was used, the reconstructed droplet size distribution from the ESI interface had an average diameter of 184 nm with a geometric standard deviation of 1.4. For the first configuration, the linear working range was wider for ESI-MS than CR-DMA-CPC. For the second configuration, the detection efficiency, defined as the fraction of molecules flowing through the ESI interface that are ultimately detected by the CPC, was on the order of 10−6. Simultaneous measurements with ELSD and CPC were consistent with analyte molecular size and may provide a means of estimating the size of unknown particles. PMID:19924869

  14. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.D.; Udseth, H.R.; Barinaga, C.J.

    1995-06-13

    An improvement to the system and method is disclosed for analyzing molecular constituents of a composition sample that comprises improvements to an electrospray ionization source for interfacing to mass spectrometers and other detection devices. The improvement consists of establishing a unique electrical circuit pattern and nozzle configuration, a metallic coated and conical shaped capillary outlet, coupled with sizing of the capillary to obtain maximum sensitivity. 10 figs.

  15. Modeling Electrospray Deposition of Nanoparticle Inks

    NASA Astrophysics Data System (ADS)

    Li, Ao; Fideles da Silva, Jefferson; Yong, Xin

    2015-11-01

    Electrospray of nanoparticle inks is of great importance to the manufacturing of functional materials. In this study, we develop a new three-dimensional multiphysics method to model the electrospray of colloidal suspension to a flat substrate. The Lagrangian Particle Tracking (LPT) transport equation is coupled to mass and heat transfer using convective droplet vaporization model, which allow us to track each particle-laden ink droplets and dry nanoparticles in the electrospray plume and probe the deposit structures. Herein, we consider dilute inks that are experimentally relevant, assuming monodisperse nanoparticles. We characterize the overall statistics of the plume and the dynamics of individual ink droplet or dry nanoparticle. It is shown that the segregation effect affects not only primary and satellite droplets but also dry nanoparticles. We observe nanoparticles deposit structure changing process, in particular time evolution of the density profile along radial direction. Our results show that the region of high nanoparticle density transitioning from only the edge to both the edge and center, which agrees with previous experimental studies.

  16. Self-assembled nanostructures via electrospraying

    NASA Astrophysics Data System (ADS)

    Jayasinghe, S. N.

    2006-07-01

    A concentrated nanoparticulate-based ethylene glycol suspension was prepared and electrosprayed at optimum and stable cone-jet mode conditions. Using laser spectroscopy, the droplets were measured and found to range within ∼0.23-3.8 μm. In parallel to spectroscopy-assisted sizing, a volume equivalence route for estimating droplet sizes was carried out by measuring contact angles and diameters of the deposits. The electrosprayed nanosuspension relics were examined using optical and transmission electron microscopy. These deposits were further characterized using energy-dispersive X-rays and selected area electron diffraction. Simultaneously deposits were formed by a controlled route through needle deposition without the presence of an electric field. The structures formed in this non-electric field driven route are compared with those formed with electric fields. Thus, elucidating electrosprays as a competing nanofabrication route for forming self-assemblies with a wide range of nanomaterials in the nanoscale for top-down based bottom-up assembly of structures.

  17. Development and characterization of electrosprayed Alyssum homolocarpum seed gum nanoparticles for encapsulation of d-limonene.

    PubMed

    Khoshakhlagh, Khadije; Koocheki, Arash; Mohebbi, Mohebbat; Allafchian, Alireza

    2017-03-15

    In this study, the feasibility of developing Alyssum homolocarpum seed gum (AHSG) nanocapsules containing d-limonene by electrospraying has been investigated. d-limonene emulsions with constant AHSG (0.5% w/w) and various flavor concentrations (10-30% based on gum weight) with 0.1% Tween 20 were electrosprayed at 20kV and 0.1ml/h of flow rate. The effects of key parameters of emulsions (rheological properties, droplet size, surface tension and electrical conductivity) on the morphology of structures have been studied. The morphology of nanocapsules had strong dependency on solution properties. The aggregated irregular shaped nanoparticles were obtained from electrospraying of AHSG solution. After incorporation of 10 and 20% d-limonene, spherical nanocapsules were yielded. However, morphology of nanocapsules changed to nanofibers by increasing the flavor content to 30%. The encapsulation efficiency for 10 and 20% d-limonene loaded nanocapsules was around 87-93%. Attenuated total reflectance-fourier transform infrared spectroscopy (ATR-FTIR), X-ray diffraction (XRD), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA) were also employed to study the physicochemical characteristics of nanocapsules. These experiments provided evidences that electrosprayed AHSG nanoparticles introduce a novel and efficient carrier for encapsulation of bioactive ingredients.

  18. Relaxation times in single event electrospraying controlled by nozzle front surface modification.

    PubMed

    Stachewicz, Urszula; Dijksman, J Frits; Burdinski, Dirk; Yurteri, Caner U; Marijnissen, Jan C M

    2009-02-17

    Single event electrospraying (SEE) is a method for on-demand deposition of femtoliter to picoliter volumes of fluids. To determine the influence of the size of the meniscus on the characteristics of the single event electrospraying process, glass capillaries were used with and without an antiwetting coating comprising a self-assembled 1H,1H,2H,2H-perfluorodecyltrichlorosilane-based monolayer to control the meniscus size. A large difference was found in driving single event electrospraying from a small meniscus compared to what is needed to generate a single event electrospraying from a large meniscus. Furthermore, after studying the different time constants related to the electrical and the hydrodynamic phenomena, we are able to explain the timing limitations of the deposition process from both a small and a large meniscus. The hydrodynamic relaxation time is significantly reduced in the case of the modified capillary, and the timing of SEE, which determines the deposition time, is limited by the resistor-capacitor RC time of the electrical circuit needed to drive the SEE. We have built a model that describes the almost one-dimensional motion of the liquid in the capillary during pulsing. The model has been used to estimate the hydrodynamic relaxation times related to the meniscus-to-cone and cone-to-meniscus transitions during SEE. By confining the meniscus to the inner diameter of the nozzle, we are able to deposit a volume smaller than 5 pL per SEE.

  19. Fabrication of micro-patterns via near-field electrospray

    NASA Astrophysics Data System (ADS)

    Li, Wenwang; Zheng, Gaofeng; Xu, Lei; Wang, Xiang

    2016-11-01

    A near-field electrospray process is developed to deposited micro-patterns. Compared with conventional electrospray, near field electrospray uses a steel probe instead of capillary nozzle, and its nozzle-to-substrate distance is shortened to several millimeters to realize micro-scale deposition area. The liquid is supplied by discretely dipping the probe into solution in advance so that electrospray process maintains until the consumption of liquid adhered at the probe tip. The influence of solution conductivity and applied voltage on deposition are investigated, as increasing solution conductivity and high applied voltage may promote the electrospray process and enlarge the line width. In addition, micro-patterns with various materials are directly electrosprayed.

  20. A Growth Curve Analysis of the Joint Influences of Parenting Affect, Child Characteristics and Deviant Peers on Adolescent Illicit Drug Use

    ERIC Educational Resources Information Center

    Pires, Paulo; Jenkins, Jennifer M.

    2007-01-01

    This study purports that parental rejection and warmth are critical to the development of adolescent drug use, and investigates a model that also considers children's vulnerability and deviant peer affiliations. It tests mediation through the proximal risk factor of deviant peers. Poisson growth curve modeling was used to examine participants from…

  1. Perspective on Electrospray Ionization and Its Relation to Electrochemistry

    NASA Astrophysics Data System (ADS)

    Pozniak, Boguslaw P.; Cole, Richard B.

    2015-03-01

    The phenomenon of electrospraying of liquids is presented from the perspective of the electrochemistry involved. Basics of current and liquid flow in the capillary and spray tip are discussed, followed by specifics of charging and discharging of the sprayed liquid surface. Fundamental theories and numerical modeling relating electrospray current to solution and spray parameters are described and then compared with our own experimentally obtained data. The method of mapping potentials and currents inside the electrospray capillary by using an inserted electrically-isolated small wire probe electrode is discussed in detail with illustrations from new and published data. Based on these experimentally obtained results, a new mathematical model is derived. The introduced "nonlinear resistor electrospray capillary model" divides the electrospray capillary into small sections, adds their contributions, and then, by transition to infinitely small section thickness, produces analytical formulas that relate current and potential maps to other properties of the electrospraying liquid: primarily conductivity and current density. The presentation of the model is undertaken from an elementary standpoint, and it offers the possibility to obtain quantitative information regarding operating parameters from typical analytical systems subjected to electrospray. The model stresses simplicity and ease of use; examples applying experimental data are shown and some predictions of the model are also presented. The developed nonlinear resistor electrospray capillary model is intended to provide a new quantitative basis for improving the understanding of electrochemical transformations occurring in the electrospray emitter. A supplemental material section gives full derivation of the model and discusses other consequences.

  2. Activation or block of adenosine triphosphate-sensitive potassium channel have opposite effects on postcardioplegic myocardial dysfunction, "stunning". A multivariate prediction based on relative operating characteristic curve.

    PubMed

    Puddu, P E; Sugimoto, S; Monti, F; Iwashiro, K; Dawodu, A A; Schiariti, M; Chiavarelli, R; Marino, B; Campa, P P

    1995-09-01

    contrast, after 60 min of reoxygenation %DT/TPT in N (118 +/- 35%, p < 0.05 vs C, p < 0.01 vs G) was improved (intergroup F = 5.48, p < 0.002). G, NA and NT showed recovery of contractility similar to C. However, after dobutamine the poorest %DT/TPT were seen in G (p < 0.01 vs C, p < 0.05 vs N). In study B): using the multivariate logistic model, with KATP activation, the odds of normal contractile response, respectively at 60 min of reoxygenation (t = 2.81) and after dobutamine (t = 3.22), were 29.8 and 8.86 of controls, whereas TTA (t = -1.59) was inversely related. Moreover, with KATP block the odds after dobutamine was 0.204 of controls. The relative operating characteristic plots showed areas under the curve greater than 0.7, which is evidence for accurate assessment of the predictive rules adopted. This is the first report where a probabilistic approach to cardioplegia-related experiments showed high accuracy in predicting the recovery of post-hypoxic contractile function (stunning). The results indicate that on postcardioplegic stunning: 1) KATP activation by N and KATP block by G (both given prior to or contemporary with hypoxia) have opposite effects; 2) the favorable effects of nicorandil seem unrelated to its nicotinamide or nitrose moieties.

  3. Rapid identification of acetophenones in two Cynanchum species using liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Zhang, Xi; Shan, Lei; Huang, Hao; Yang, Xianwen; Liang, Xu; Xing, Aiting; Huang, Haiqiang; Liu, Xinru; Su, Juan; Zhang, Weidong

    2009-04-05

    Acetophenones in Cynanchum species, especially cynandione A and its derivatives, whose utilization and toxicity in herbal drugs and folk medicines has caused great interest in the chemical investigation, have extensive biological activities. In this paper, a facile method based on high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (HPLC-ESI-MS(n)) was developed for the analysis of cynandione A derivatives in the roots of the Cynanchum wilfordii and C. auriculatum. ESI-MS/MS and ESI-MS(n) analysis of cynandiones A and B in negative ion mode were firstly performed employing two mass spectrometers each equipped with an ion-trap and a quadrupole time-of-flight (Q-TOF) mass analyzer. The results drawn from both instruments were similar to each other. Characteristic fragmentation pathways were proposed by comparing the spectra of two standards acquired in the experiments. The fragment ions at m/z 283 and 268 were obtained, and then were used as diagnostic ions to screen and identify cynandione A derivatives from the roots of above two species, together with an HPLC-MS(n) method. Total of 28 cynandione A derivatives comprising 4 reported and 24 novel components were identified or tentatively identified. Furthermore, breakdown curves were constructed to distinguish two types of isomers among these compounds. To our knowledge, this is the first report on characterization of acetophenones by HPLC-ESI-MS(n), which allows a rapid and complete analysis of cynandione A derivatives in roots of Cynanchum species.

  4. Multi-Reader Multi-Case Studies Using the Area under the Receiver Operator Characteristic Curve as a Measure of Diagnostic Accuracy: Systematic Review with a Focus on Quality of Data Reporting

    PubMed Central

    Dendumrongsup, Thaworn; Plumb, Andrew A.; Halligan, Steve; Fanshawe, Thomas R.; Altman, Douglas G.; Mallett, Susan

    2014-01-01

    Introduction We examined the design, analysis and reporting in multi-reader multi-case (MRMC) research studies using the area under the receiver-operating curve (ROC AUC) as a measure of diagnostic performance. Methods We performed a systematic literature review from 2005 to 2013 inclusive to identify a minimum 50 studies. Articles of diagnostic test accuracy in humans were identified via their citation of key methodological articles dealing with MRMC ROC AUC. Two researchers in consensus then extracted information from primary articles relating to study characteristics and design, methods for reporting study outcomes, model fitting, model assumptions, presentation of results, and interpretation of findings. Results were summarized and presented with a descriptive analysis. Results Sixty-four full papers were retrieved from 475 identified citations and ultimately 49 articles describing 51 studies were reviewed and extracted. Radiological imaging was the index test in all. Most studies focused on lesion detection vs. characterization and used less than 10 readers. Only 6 (12%) studies trained readers in advance to use the confidence scale used to build the ROC curve. Overall, description of confidence scores, the ROC curve and its analysis was often incomplete. For example, 21 (41%) studies presented no ROC curve and only 3 (6%) described the distribution of confidence scores. Of 30 studies presenting curves, only 4 (13%) presented the data points underlying the curve, thereby allowing assessment of extrapolation. The mean change in AUC was 0.05 (−0.05 to 0.28). Non-significant change in AUC was attributed to underpowering rather than the diagnostic test failing to improve diagnostic accuracy. Conclusions Data reporting in MRMC studies using ROC AUC as an outcome measure is frequently incomplete, hampering understanding of methods and the reliability of results and study conclusions. Authors using this analysis should be encouraged to provide a full description of

  5. Transport and Deposition of Electrosprayed Nanoparticles

    NASA Astrophysics Data System (ADS)

    Brown, Nicholas; Chiarot, Paul

    2015-11-01

    In an electrospray, high electric potentials are utilized to generate a fine aerosol of a conductive solvent. For this study, the solvent consisted of nanoparticles dispersed in alcohol. The nanoparticle suspensions act as printable nanoparticle inks. In this process, a glass capillary tube is held as a high electric potential relative to a grounded reference plate located below the tip. Droplets are ejected from the tube and are directed towards the ground plate. If the solvent is sufficiently volatile, it will rapidly evaporate while the droplets are in flight (due to the high surface area to volume ratio) leaving behind dry, highly charged nanoparticles. The droplets/nanoparticles are deposited onto a target substrate that is place onto the grounded plate. The transport of any individual droplet/nanoparticle from the emitter tip to the target substrate is a stochastic process. This transport can be modeled using a Monte Carlo simulation. The probability of an individual particle being deposited at a given location on the target substrate is directly related to the electric potential at that location. In other words, the probability function that determines the deposition is directly related to the electric potential at the substrate. The total potential is comprised of the applied electric potential required to generate the electrospray, the induced charge on the surface of the target dielectric, and the charge on the individual particles themselves. We report on the structure of droplet/nanoparticle deposits printed using electrospray. The evolution of the deposit is investigated over time using experimental studies and Monte Carlo simulations. The deposit structure passes through four distinct regimes that are characterized by repeatable bulk features.

  6. Initial slope of radiation survival curves is characteristic of the origin of primary and established cultures of human tumor cells and fibroblasts

    SciTech Connect

    Malaise, E.P.; Fertil, B.; Deschavanne, P.J.; Chavaudra, N.; Brock, W.A.

    1987-08-01

    The published survival curves of 110 human tumor cell lines and 147 nontransformed human fibroblast strains have been reanalyzed using three different statistical methods: the single hit multitarget model, the linear-quadratic model, and the mean inactivation dose. The 110 tumor cell lines were classified in two ways: (a) into three categories defined by clinical radiocurability criteria, and (b) into seven categories based on histopathology. The 147 fibroblast strains were divided into eight genetic groups. Differences in the radiosensitivities of both the tumor cell and fibroblast groups could be demonstrated only by parameters that describe the slopes of the initial part of the survival curves. The capacity of the survival level to identify significant differences between groups was dose dependent over the range 1 to 6 Gy. This relationship showed a bell-shaped curve with a maximum at 1.5 Gy for the tumor cell lines and 3 Gy for the fibroblasts. Values for intrinsic radiosensitivity for a number of groups of tumors have also been obtained by primary culture of tumor cells. These values are strictly comparable to those obtained by clonogenic methods. This confirms that intrinsic radiosensitivity is a determinant of the response of tumor cells to radiotherapy and suggests that tissue culture methods may be used as a predictive assay.

  7. Application of electrospraying as a one-step method for the fabrication of triamcinolone acetonide-PLGA nanofibers and nanobeads.

    PubMed

    Jahangiri, Azin; Davaran, Soodabeh; Fayyazi, Behnam; Tanhaei, Ali; Payab, Shahriar; Adibkia, Khosro

    2014-11-01

    The aim of the present project was to prepare triamcinolone acetonide nanofibers and nanobeads with prolonged anti-inflammatory activity. Triamcinolone acetonide-loaded PLGA nanoformulations were prepared by electrospraying method. The physicochemical and morphological properties of the fabricated nanoparticles were characterized as well. In vitro drug release of the prepared formulations was also studied. Differential scanning calorimetry and X-ray powder diffractometery showed that drug crystallinity was notably decreased during the electrospraying process. In vitro dissolution tests verified that the pure drug and physical mixtures had faster drug release pattern compared to the nanoformulations. Electrosprayed samples with the drug:polymer ratio of 1:10 revealed slower release profiles compared to those with a 1:5 ratio. Results obtained from SEM images of the prepared formulations indicated that polymer solution concentration was the critical parameter in the formation of fibers or beads; so that, fiber formation was increased proportionally with increasing polymer concentration. Moreover, the size of obtained nanostructures was also increased in order of polymer concentrations. As a final point, electrosprayed triamcinolone-loaded biodegradable micro/nanofibers and nanobeads with modified physicochemical characteristics and sustained drug release profiles were successfully prepared via simple, one-step and cost effective electrospraying technique.

  8. The electrospray: Fundamentals and combustion applications

    NASA Technical Reports Server (NTRS)

    Gomez, Alessandro

    1993-01-01

    Liquid fuel dispersion in practical systems is typically achieved by spraying the fuel into a polydisperse distribution of droplets evaporating and burning in a turbulent gaseous environment. In view of the nearly unsurmountable difficulties of this two-phase flow, it would be useful to use an experimental arrangement that allow a systematic study of spray evolution and burning in configurations of gradually increasing levels of complexity, starting from laminar sprays to fully turbulent ones. An Electrostatic Spray (ES) of charged droplets lends itself to this type of combustion experiments under well-defined conditions and can be used to synthesize gradually more complex spray environments. In its simplest configuration, a liquid is fed into a small metal tube maintained at several kilovolts relative to a ground electrode few centimeters away. Under the action of the electric field, the liquid meniscus at the outlet of the capillary takes a conical shape, with a thin jet emerging from the cone tip. This jet breaks up farther downstream into a fine spray of charged droplets. Several advantages distinguish the electrospray from alternative atomization techniques: the self-dispersion property of the spray due to coulombic repulsion; the absence of droplet coalescence; the potential control of the trajectories of charged droplets by suitable disposition of electrostatic fields; and the decoupling of atomization, which is strictly electrostatic, from gas flow processes. Furthermore, as recently shown in our laboratory, the electrospray can produce quasi-monodisperse droplets over a very broad size range (1-100 microns). The ultimate objective of this research project is to study the formation and burning of electrosprays of liquid fuels first in laminar regimes and then in turbulent ones. Combustion will eventually be investigated in conditions of three-dimensional droplet-droplet interaction, for which experimental studies have been limited to either qualitative

  9. Some thoughts on electrospray ionization mechanisms.

    PubMed

    Crotti, Sara; Seraglia, Roberta; Traldi, Pietro

    2011-01-01

    Electrospray ionization (ESI) mechanisms are highly complex, due to a series of physical and chemical phenomena taking place on a complex system, as a solution is. In fact, even if the solution of an analyte in a protic medium can be considered at first sight to be a two-component system, the presence of solvent dissociation equilibria and the possible interactions solvent-solvent dissociation products, solvent dissociation products-analyte make this system highly complex, also for the presence of possible ionic compounds (for example, Na(+), K(+)) which strongly affect the above equilibria. A high number of research articles have been published, mainly devoted to charged droplet production and to gas-phase ion generation. They all show the high complexity of the processes affecting electrospray measurements related to either the chemical equilibria present in the condensed phase and to electrolysis processes at the emitter tip or to the processes occurring in the sprayed droplets. As a result, the chemical composition inside the small droplets from which the analyte ions are generated can be significantly different from those in sprayed solution. In this review, after a short survey of the proposed ESI mechanisms, some experiments are described. They were performed to examine if ion mobility in solution, before the formation of the sprayed charged droplets, can affect the ESI results. The data, obtained by studying both inorganic and organic analytes, indicate that the ESI spectra are dependent on the analyte dimension and charge state which, as a consequence, affect their ion mobility in solution.

  10. The thermoluminescence characteristics and the glow curves of Thulium doped silica fiber exposed to 10MV photon and 21MeV electron radiation.

    PubMed

    Alawiah, A; Alina, M S; Bauk, S; Abdul-Rashid, H A; Gieszczyk, W; Noramaliza, M N; Mahdiraji, G A; Tamchek, N; Zulkifli, M I; Bradley, D A; Marashdeh, M W

    2015-04-01

    The thermoluminescence (TL) glow curves and kinetics parameters of Thulium (Tm) doped silica cylindrical fibers (CF) are presented. A linear accelerator (LINAC) was used to deliver high-energy radiation of 21MeV electrons and 10MV photons. The CFs were irradiated in the dose range of 0.2-10Gy. The experimental glow curve data was reconstructed by using WinREMS. The WinGCF software was used for the kinetic parameters evaluation. The TL sensitivity of Tm-doped silica CF is about 2 times higher as compared to pure silica CF. Tm-doped silica CF seems to be more sensitive to 21MeV electrons than to 10MV photons. Surprisingly, no supralinearity was displayed and a sub-linear response of Tm-doped silica CF was observed within the analyzed dose range for both 21MeV electrons and 10MV photons. The Tm-doped silica CF glow curve consists of 5 individual glow peaks. The Ea of peak 4 and peak 5 was highly dependent on dose when irradiated with photons. We also noticed that the electron radiation (21MeV) caused a shift of glow peak by 7-13°C to the higher temperature region compared with photons radiation (10MV). Our Tm-doped fibers seem to give high TL response after 21MeV electrons, which gives around 2 times higher peak integral as compared with 10MV photon radiation. We concluded that peak 4 is the first-order kinetic peak and can be used as the main dosimetric peak of Tm-doped silica CF.

  11. Coaxial electrospray of microparticles and nanoparticles for biomedical applications.

    PubMed

    Zhang, Leilei; Huang, Jiwei; Si, Ting; Xu, Ronald X

    2012-11-01

    Coaxial electrospray is an electrohydrodynamic process that produces multilayer microparticles and nanoparticles by introducing coaxial electrified jets. In comparison with other microencapsulation/nanoencapsulation processes, coaxial electrospray has several potential advantages such as high encapsulation efficiency, effective protection of bioactivity and uniform size distribution. However, process control in coaxial electrospray is challenged by the multiphysical nature of the process and the complex interplay of multiple design, process and material parameters. This paper reviews the previous works and the recent advances in design, modeling and control of a coaxial electrospray process. The review intends to provide general guidance for coaxial electrospray and stimulate further research and development interests in this promising microencapsulation/nanoencapsulation process.

  12. Coaxial electrospray of microparticles and nanoparticles for biomedical applications

    PubMed Central

    Zhang, Leilei; Huang, Jiwei; Si, Ting; Xu, Ronald X

    2013-01-01

    Coaxial electrospray is an electrohydrodynamic process that produces multilayer microparticles and nanoparticles by introducing coaxial electrified jets. In comparison with other microencapsulation/nanoencapsulation processes, coaxial electrospray has several potential advantages such as high encapsulation efficiency, effective protection of bioactivity and uniform size distribution. However, process control in coaxial electrospray is challenged by the multiphysical nature of the process and the complex interplay of multiple design, process and material parameters. This paper reviews the previous works and the recent advances in design, modeling and control of a coaxial electrospray process. The review intends to provide general guidance for coaxial electrospray and stimulate further research and development interests in this promising microencapsulation/nanoencapsulation process. PMID:23249155

  13. Nanoparticle preparation of Mefenamic acid by electrospray drying

    SciTech Connect

    Zolkepali, Nurul Karimah Bakar, Noor Fitrah Abu Anuar, Nornizar; Naim, M. Nazli; Bakar, Mohd Rushdi Abu

    2014-02-24

    Nanoparticles preparation of Mefenamic acid (MA) by using an electrospray drying method was conducted in this study. Electrospray drying is a process that uses electrostatic force to disperse a conductive liquid stream into fine charged droplets through the coulomb fission of charges in the liquid and finally dry into fine particles. Electrospray drying modes operation usually in Taylor cone jet, and it was formed by controlling applied voltage and liquid flow rate. A conductive liquid (2.77–8.55μScm{sup −1}) which is MA solution was prepared by using acetone with concentration 0.041 and 0.055 M before pumping at a flow rate of 3–6ml/h. By applying the applied voltage at 1.3–1.5 kV, Taylor cone jet mode was formed prior to the electrospray. During electrospray drying process, solvent evaporation from the droplet was occurring that leads to coulomb disruption and may generate to nanoparticles. The dried nanoparticles were collected on a grounded substrate that was placed at varying distance from the electrospray. MA particle with size range of 100–400 nm were produced by electrospray drying process. Characterization of particles by using X-ray diffractometry (XRD) and differential scanning calorimetry (DSC) show that particles formed into polymorph I.

  14. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.D.; Udseth, H.R.; Olivares, J.A.

    1994-10-18

    A system and method for analyzing molecular constituents of a composition sample include: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g.,{+-}2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit. 21 figs.

  15. Electrospray and tandem mass spectrometry in biochemistry.

    PubMed Central

    Griffiths, W J; Jonsson, A P; Liu, S; Rai, D K; Wang, Y

    2001-01-01

    Over the last 20 years, biological MS has changed out of all recognition. This is primarily due to the development in the 1980s of 'soft ionization' methods that permit the ionization and vaporization of large, polar, and thermally labile biomolecules. These developments in ionization mode have driven the design and manufacture of smaller and cheaper mass analysers, making the mass spectrometer a routine instrument in the biochemistry laboratory today. In the present review the revolutionary 'soft ionization' methods will be discussed with particular reference to electrospray. The mass analysis of ions will be described, and the concept of tandem MS introduced. Where appropriate, examples of the application of MS in biochemistry will be provided. Although the present review will concentrate on the MS of peptides/proteins and lipids, all classes of biomolecules can be analysed, and much excellent work has been done in the fields of carbohydrate and nucleic acid biochemistry. PMID:11311115

  16. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.P.; Udseth, H.R.; Olivares, J.A.

    1989-12-05

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., [+-]2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit. 21 figs.

  17. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard D.; Udseth, Harold R.; Olivares, Jose A.

    1994-10-18

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit.

  18. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard P.; Udseth, Harold R.; Olivares, Jose A.

    1989-01-01

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit.

  19. A new cluster-ion-beam source for secondary ion mass spectrometry (SIMS) using the electrospray of a pure ionic liquid under high vacuum

    NASA Astrophysics Data System (ADS)

    Fujiwara, Yukio; Saito, Naoaki; Nonaka, Hidehiko; Nakanaga, Taisuke; Ichimura, Shingo

    2010-06-01

    Electrospray characteristics were studied using a pure room-temperature molten salt (i.e., an ionic liquid) at pressures around 10 -5 Pa as well as at atmospheric pressure. The ionic liquid N,N-diethyl-N-methyl-N-(2-methoxyethyl)ammonium bis(trifluoromethanesulfonyl)imide was tested, which has negligible vapor pressure and high conductivity. During electrospray, the ionic liquid was introduced at a constant flow rate into a stainless-steel capillary (i.d. 30 μm). It was demonstrated that stable electrosprayed currents exceeding ±1 μΑ were continuously produced in both positive and negative modes. The electrosprayed currents in a high vacuum were twice those at atmospheric pressure. It was found that gas pressure rose slightly with increasing electrosprayed currents. Residual gas analysis revealed that gas component at negative mode was different from that at positive mode. Experimental results indicate that vacuum electrospray of pure ionic liquids is applicable to a massive-cluster beam source for SIMS.

  20. Submerged electrosprays: a versatile approach for microencapsulation.

    PubMed

    Jayasinghe, S N

    2007-08-01

    The unearthing of fundamental science and technology associated with microencapsulation is an ongoing exciting scientific endeavour focused on by several scientists. Encapsulated structures (containing either a gas, molecules or materials) previously have been shown as having widespread applications across the physical and life sciences. In particular, such methodologies used for forming encapsulations in medical-related studies have shown great promise from diagnostics and imaging, to gene therapy and drug delivery which are only a few amongst several other applications. At present there are numerous 'jet-based' manifestations available for microencapsulation, these primarily root from either capillary or channel-based techniques. The driving mechanisms employed in these approaches exploit aerodynamic/pressure gradients to piezoelectricity. In this paper submerged electrosprays a multipurpose electric field driven jet-based technique is explored for forming near mono-dispersed encapsulations sized in the micrometer range. Our studies elucidate the ability to form microencapsulations containing either a gas or a micro/nanoparticulate-based material suspension as capsules sized in the ranges approximately 65-80 microm, approximately 8-25 microm to approximately 3-14 microm, respectively. We believe this technique can significantly contribute to the microencapsulation field of research based on both the size of the generated encapsulations to the containment of immiscible high viscosity particulate-based suspensions. Furthermore our investigations show the ability to control the production of these encapsulations in terms of both their size and rate of generation with ease; hence demonstrating this electrospray-assisted microencapsulation route as having a wide range of applications. It should be noted that in its present form this technique could be explored for generating emulsions with a variety of materials especially with living organisms for applications in the

  1. A research program to reduce interior noise in general aviation airplanes. Influence of depressurization and damping material on the noise reduction characteristics of flat and curved stiffened panels

    NASA Technical Reports Server (NTRS)

    Navaneethan, R.; Streeter, B.; Koontz, S.; Roskam, J.

    1981-01-01

    Some 20 x 20 aluminum panels were studied in a frequency range from 20 Hz to 5000 Hz. The noise sources used were a swept sine wave generator and a random noise generator. The effect of noise source was found to be negligible. Increasing the pressure differential across the panel gave better noise reduction below the fundamental resonance frequency due to an increase in stiffness. The largest increase occurred in the first 1 psi pressure differential. The curved, stiffened panel exhibited similar behavior, but with a lower increase of low frequency noise reduction. Depressurization on these panels resulted in decreased noise reduction at higher frequencies. The effect of damping tapes on the overall noise reduction values of the test specimens was small away from the resonance frequency. In the mass-law region, a slight and proportional improvement in noise reduction was observed by adding damping material. Adding sound absorbtion material to a panel with damping material beneficially increased noise reduction at high frequencies.

  2. An investigation of thermocapillary effects on the wetting characteristics of a heated, capillary re-supplied, curved meniscus within a capillary pore

    SciTech Connect

    Pratt, D.M.; Hallinan, K.P.

    1996-12-31

    An investigation of thermocapillary effects on a heated, evaporating meniscus formed by a wetting liquid in a vertical capillary tube has been completed. Experiments were conducted to primarily observe how the wetting characteristics of the working fluid (pentane) are affected by the dynamics associated with the heating of and evaporation from a meniscus. The results have demonstrated that interfacial thermocapillary stresses arising from liquid-vapor interfacial temperature gradients can noticeably degrade the ability of the liquid to wet the pore.

  3. Application of co-eluting structural analog internal standards for expanded linear dynamic range in liquid chromatography/electrospray mass spectrometry.

    PubMed

    Shi, Guoen

    2003-01-01

    Non-linear standard calibration curves occur frequently in liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS), necessitating the use of non-linear regression curve fitting or a reduction in assay dynamic range. Non-linearity can be minimized by the use of stable isotope internal standards, if the cause of curve bending is ionization saturation. Unfortunately, stable isotope internal standards can be difficult or expensive to synthesize. Structural analog internal standards, if sufficiently close to analytes both in chemical structures and HPLC retention times, may mimic the effect of stable isotope internal standards. Tentative experimental evidence supporting this concept is presented in this paper.

  4. Electrospray-printed nanostructured graphene oxide gas sensors.

    PubMed

    Taylor, Anthony P; Velásquez-García, Luis F

    2015-12-18

    We report low-cost conductometric gas sensors that use an ultrathin film made of graphene oxide (GO) nanoflakes as transducing element. The devices were fabricated by lift-off metallization and near-room temperature, atmospheric pressure electrospray printing using a shadow mask. The sensors are sensitive to reactive gases at room temperature without requiring any post heat treatment, harsh chemical reduction, or doping with metal nanoparticles. The sensors' response to humidity at atmospheric pressure tracks that of a commercial sensor, and is linear with changes in humidity in the 10%-60% relative humidity range while consuming <6 μW. Devices with GO layers printed by different deposition recipes yielded nearly identical response characteristics, suggesting that intrinsic properties of the film control the sensing mechanism. The gas sensors successfully detected ammonia at concentrations down to 500 ppm (absolute partial pressure of ∼5 × 10(-4) T) at ∼1 T pressure, room temperature conditions. The sensor technology can be used in a great variety of applications including air conditioning and sensing of reactive gas species in vacuum lines and abatement systems.

  5. The Analysis of the Reliability and Factorial Validity in the Basic Characteristics of Isometric F-t curve of the Leg Extensors in Well Trained Serbian Males and Females

    NASA Astrophysics Data System (ADS)

    Dopsaj, Milivoj; Ivanović, Jelena

    2011-01-01

    The aim of this research was to establish the reliability and factorial validity of different isometric basic characteristics of F-t curve related to leg extensors in well trained and healthy Serbian males and females. Sample consisted of 159 examinees. In order to assess characteristics of the F-t isometric leg extensor force, tensiometric probe and standardized "seating leg extension" test were used. The measurement range was defined by 4 variables regarding the contractile characteristics of the leg extensor isometric muscle force - 1) the level of the achieved maximal force - FmaxLegExtISO, 2) the indicator of basic (general) level of rate of force development - RFDBASICLegExtISO, 3) the time necessary to reach maximal force - tFmaxLegExtISO, 4) basic synergy index. The results showed a high statistical significance of p<0.001 in representability, generalizability and reliability for all the characteristics observed in both genders (Spearman-Brown r - 0.715 to 0.967 for males and 0.713 to 0.941 for females). As for the methodology aspect of testing, the factor analysis demonstrated the necessity of conducting at least three trials, choosing the best result from the two last trials.

  6. Fabrication and Testing of Tapered Electro-spray Nozzles

    DTIC Science & Technology

    2012-09-01

    oxidized nozzle with broken top cap. 15 The ultrasonic breaking of the etch mask was found to be a low-yield methodology, with some caps breaking...Fabrication and Testing of Tapered Electro-spray Nozzles by Brendan M. Hanrahan and C. Mike Waits ARL-TR-6226 September 2012...September 2012 Fabrication and Testing of Tapered Electro-spray Nozzles Brendan M. Hanrahan and C. Mike Waits Sensors and Electron Devices

  7. Subcellular analysis by laser ablation electrospray ionization mass spectrometry

    DOEpatents

    Vertes, Akos; Stolee, Jessica A; Shrestha, Bindesh

    2014-12-02

    In various embodiments, a method of laser ablation electrospray ionization mass spectrometry (LAESI-MS) may generally comprise micro-dissecting a cell comprising at least one of a cell wall and a cell membrane to expose at least one subcellular component therein, ablating the at least one subcellular component by an infrared laser pulse to form an ablation plume, intercepting the ablation plume by an electrospray plume to form ions, and detecting the ions by mass spectrometry.

  8. Laser electrospray mass spectrometry of adsorbed molecules at atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Brady, John J.; Judge, Elizabeth J.; Simon, Kuriakose; Levis, Robert J.

    2010-02-01

    Atmospheric pressure mass analysis of solid phase biomolecules is performed using laser electrospray mass spectrometry (LEMS). A non-resonant femtosecond duration laser pulse vaporizes native samples at atmospheric pressure for subsequent electrospray ionization and transfer into a mass spectrometer. LEMS was used to detect a complex molecule (irinotecan HCl), a complex mixture (cold medicine formulation with active ingredients: acetaminophen, dextromethorphan HBr and doxylamine succinate), and a biological building block (deoxyguanosine) deposited on steel surfaces without a matrix molecule.

  9. Ambient gas influence on electrospray potential as revealed by potential mapping within the electrospray capillary.

    PubMed

    Pozniak, Boguslaw P; Cole, Richard B

    2007-05-01

    The effect of ambient gas on potentials inside the electrospray (ES) capillary was investigated. Potential measurements and differential electrospray emitter potential (DEEP) maps were obtained with the help of a small, movable, disklike platinum wire electrode inserted into the ES capillary. Typical solvents used for electrospray mass spectrometry such as methanol and mixtures of methanol-water and chloroform/methanol have been tested. It was found that oxygen is readily adsorbed from the surrounding ambient gas into the spraying liquid. Following adsorption, it resides in, or near to, the Taylor cone, thereby affecting the electrochemical potential near the ES capillary exit, as well as the character of the inherent electrochemical reactions occurring during the ES process. The potentials measured in an air environment with reactive oxygen present are contrasted against those obtained in an inert nitrogen environment. The kinetics of oxygen admission have been found to be quite fast, i.e., occurring in a matter of seconds, but it takes far longer to purge the system of oxygen by changing the ambient atmosphere to nitrogen. The oxygen effect is present in negative and positive ion modes of ES, but the total ES current is not affected by the change of ambient gas. The magnitude of the oxygen effect owing to ambient air was compared to the effect caused by initially dissolving oxygen in the solution prior to the start of ES; it was found that the presence of oxygen in the ambient gas has a far greater consequence. These results indicate that the presence of reactive gases, such as molecular oxygen, in the region of the ES emitter may have unintended secondary effects on the ES process prior to mass spectrometric analysis.

  10. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    SciTech Connect

    Ford, Michael J; Deibel, Michael A.; Tomkins, Bruce A; Van Berkel, Gary J

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  11. Harmonic Measure of Critical Curves

    SciTech Connect

    Bettelheim, E.; Rushkin, I.; Gruzberg, I.A.; Wiegmann, P.

    2005-10-21

    Fractal geometry of critical curves appearing in 2D critical systems is characterized by their harmonic measure. For systems described by conformal field theories with central charge c{<=}1, scaling exponents of the harmonic measure have been computed by Duplantier [Phys. Rev. Lett. 84, 1363 (2000)] by relating the problem to boundary two-dimensional gravity. We present a simple argument connecting the harmonic measure of critical curves to operators obtained by fusion of primary fields and compute characteristics of the fractal geometry by means of regular methods of conformal field theory. The method is not limited to theories with c{<=}1.

  12. Micro-electrospray with stainless steel emitters.

    PubMed

    Shui, Wenqing; Yu, Yanling; Xu, Xuejiao; Huang, Zhenyu; Xu, Guobing; Yang, Pengyuan

    2003-01-01

    The physical processes underlying micro-electrospray (micro-ES) performance were investigated using a stainless steel (SS) emitter with a blunt tip. Sheathless micro-ES could be generated at a blunt SS tip without any tapering or sanding if ESI conditions were optimized. The Taylor cone was found to shrink around the inner diameter of the SS tubing, which permitted a low flow rate of 150 nL/min for sheathless microspray on the blunt tip (100 microm i.d. x 400 microm o.d.). It is believed that the wettability and/or hydrophobicity of SS tips are responsible for their micro-ES performance. The outlet orifice was further nipped to reduce the size of the spray cone and limit the flow rate to 50-150 nL/min, resulting in peptide detection down to attomole quantities consumed per spectrum. The SS emitter was also integrated into a polymethylmethacrylate microchip and demonstrated satisfactory performance in the analysis and identification of a myoglobin digest.

  13. Multiplexed electrospray scaling for liquid fuel injection

    NASA Astrophysics Data System (ADS)

    Waits, C. Mike; Hanrahan, Brendan; Lee, Ivan

    2010-10-01

    Evaporation and space-charge requirements are evaluated to understand the effect of device scaling and fuel preheating for a liquid fuel injector using a multiplexed electrospray (MES) configuration in compact combustion applications. This work reveals the influence of the droplet diameter, droplet velocity and droplet surface temperature as well as the surrounding gas temperature on the size and performance of microfabricated MES. Measurements from MES devices are used in the model to accurately account for the droplet diameter versus flow rate relationship, the minimum droplet diameter and the relevant droplet velocities. A maximum extractor electrode to ground electrode distance of 3.1 mm required to overcome space-charge forces is found to be independent of voltage or droplet velocity for large levels of multiplexing. This maximum distance also becomes the required evaporation length scale which imposes minimum fuel pre-heating requirements for large flow densities. Required fuel preheating is therefore evaluated for both ethanol and 1-butanol with combustor parameters relevant to fuel reformation, thermoelectric conversion, thermophotovoltaic conversion and thermionic conversion.

  14. Electrochemical processes in electrospray ionization mass spectrometry

    PubMed

    Mora; Van Berkel GJ; Enke; Cole; Martinez-Sanchez; Fenn

    2000-08-01

    Editorial Comment Last month we presented, as a Special Feature, a set of five articles that constituted a Commentary on the fundamentals and mechanism of electrospray ionization (ESI). These articles produced some lively discussion among the authors on the role of electrochemistry in ESI. Six authors participated in a detailed exchange of views on this topic, the final results of which constitute this month's Special Feature. We particularly hope that younger scientists will find value in this month's Special Feature, not only for the science that it teaches but also what it reveals about the processes by which scientific conclusions are drawn. To a degree, the contributions part the curtains on these processes and show science in action. We sincerely thank the contributors to this discussion. The give and take of intellectual debate is not always easy, and to a remarkable extent this set of authors has maintained good humor and friendships, even when disagreeing strongly on substance. Graham Cooks and Richard Caprioli Copyright 2000 John Wiley & Sons, Ltd.

  15. Protein Viability on Au Nanoparticles during an Electrospray and Electrostatic-Force-Directed Assembly Process

    DOE PAGES

    Mao, Shun; Lu, Ganhua; Yu, Kehan; ...

    2010-01-01

    We study the protein viability on Au nanoparticles during an electrospray and electrostatic-force-directed assembly process, through which Au nanoparticle-antibody conjugates are assembled onto the surface of carbon nanotubes (CNTs) to fabricate carbon nanotube field-effect transistor (CNTFET) biosensors. Enzyme-linked immunosorbent assay (ELISA) and field-effect transistor (FET) measurements have been used to investigate the antibody activity after the nanoparticle assembly. Upon the introduction of matching antigens, the colored reaction from the ELISA and the change in the electrical characteristic of the CNTFET device confirm that the antibody activity is preserved during the assembly process.

  16. Separation and characterization of phenolic compounds from dry-blanched peanut skins by liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Ma, Yuanyuan; Kosińska-Cagnazzo, Agnieszka; Kerr, William L; Amarowicz, Ryszard; Swanson, Ruthann B; Pegg, Ronald B

    2014-08-22

    A large variety of phenolic compounds, including phenolic acids (hydroxybenzoic acids, hydroxycinnamic acids, and their esters), stilbenes (trans-resveratrol and trans-piceatannol), flavan-3-ols (e.g., (-)-epicatechin, (+)-catechin, and their polymers {the proanthocyanidins, PACs}), other flavonoids (e.g., isoflavones, flavanols, and flavones, etc.) and biflavonoids (e.g., morelloflavone), were identified in dry-blanched peanut skins (PS) by this study. High-performance liquid chromatography (HPLC) coupled with electrospray ionization mass spectrometry (ESI-MS(n)) was applied to separate and identify the phenolic constituents. Reversed-phase HPLC was employed to separate free phenolic compounds as well as PAC monomers, dimers, and trimers. PACs with a degree of polymerization (DP) of >4 were chromatographed via hydrophilic interaction liquid chromatography (HILIC). Tentative identification of the separated phenolics was based solely on molecular ions and MS(n) fragmentation patterns acquired by ESI-MS in the negative-ion mode. The connection sequence of PAC oligomers (DP <5) could be deduced mainly through characteristic quinone methide (QM) cleavage ions. When the DP reached 6, only a proportion of the flavan-3-ols could be ascertained in the PACs because of the extremely complicated fragmentation patterns involved. The identification of free phenolic acids, stilbenes, and flavonoids was achieved by authentic commercial standards and also by published literature data. Quantification was performed based on peak areas of the UV (free phenolic compounds) or fluorescence (PACs) signals from the HPLC chromatograms and calibration curves of commercial standards. Overall, PS contain significantly more PACs compared to free phenolic compounds.

  17. A user-friendly, menu-driven, language-free laser characteristics curves graphing program for desk-top IBM PC compatible computers

    NASA Technical Reports Server (NTRS)

    Klutz, Glenn

    1989-01-01

    A facility was established that uses collected data and feeds it into mathematical models that generate improved data arrays by correcting for various losses, base line drift, and conversion to unity scaling. These developed data arrays have headers and other identifying information affixed and are subsequently stored in a Laser Materials and Characteristics data base which is accessible to various users. The two part data base: absorption - emission spectra and tabulated data, is developed around twelve laser models. The tabulated section of the data base is divided into several parts: crystalline, optical, mechanical, and thermal properties; aborption and emission spectra information; chemical name and formulas; and miscellaneous. A menu-driven, language-free graphing program will reduce and/or remove the requirement that users become competent FORTRAN programmers and the concomitant requirement that they also spend several days to a few weeks becoming conversant with the GEOGRAF library and sequence of calls and the continual refreshers of both. The work included becoming thoroughly conversant with or at least very familiar with GEOGRAF by GEOCOMP Corp. The development of the graphing program involved trial runs of the various callable library routines on dummy data in order to become familiar with actual implementation and sequencing. This was followed by trial runs with actual data base files and some additional data from current research that was not in the data base but currently needed graphs. After successful runs, with dummy and real data, using actual FORTRAN instructions steps were undertaken to develop the menu-driven language-free implementation of a program which would require the user only know how to use microcomputers. The user would simply be responding to items displayed on the video screen. To assist the user in arriving at the optimum values needed for a specific graph, a paper, and pencil check list was made available to use on the trial runs.

  18. Assessment of Reproducibility of Laser Electrospray Mass Spectrometry using Electrospray Deposition of Analyte

    NASA Astrophysics Data System (ADS)

    Sistani, Habiballah; Karki, Santosh; Archer, Jieutonne J.; Shi, Fengjian; Levis, Robert J.

    2017-03-01

    A nonresonant, femtosecond (fs) laser is employed to desorb samples of Victoria blue deposited on stainless steel or indium tin oxide (ITO) slides using either electrospray deposition (ESD) or dried droplet deposition. The use of ESD resulted in uniform films of Victoria blue whereas the dried droplet method resulted in the formation of a ring pattern of the dye. Laser electrospray mass spectrometry (LEMS) measurements of the ESD-prepared films on either substrate were similar and revealed lower average relative standard deviations for measurements within-film (20.9%) and between-films (8.7%) in comparison to dried droplet (75.5% and 40.2%, respectively). The mass spectral response for ESD samples on both substrates was linear (R2 > 0.99), enabling quantitative measurements over the selected range of 7.0 × 10-11 to 2.8 × 10-9 mol, as opposed to the dried droplet samples where quantitation was not possible (R2 = 0.56). The limit of detection was measured to be 210 fmol.

  19. Structural analysis of chromophore-labeled disaccharides and oligosaccharides by electrospray ionization mass spectrometry and high-performance liquid chromatography/electrospray ionization mass spectrometry.

    PubMed

    Li, D T; Her, G R

    1998-07-01

    Disaccharides and linear oligosaccharides were labeled with p-aminobenzoic ethyl ester (ABEE) chromophore and analyzed by negative ion electrospray ionization mass spectrometry (ESIMS). The formation of glycosylamines rather than reductive amination in the labeling reaction produced many characteristic fragment ions under in source collision-induced dissociation (CID). These ions provided unambiguous assignment of the position of the glycosidic linkages. This approach was extended to the analysis of linkages and the sequence of the linkages of several linear oligosaccharides. Additionally, the anomeric configuration of ABEE-labeled 1-3-, 1-4- and 1-6-linked glucose disaccharides could be differentiated according to the relative abundance of characteristic ions. Disaccharides with the same linkage but different monosaccharide compositions could be analyzed by on-line coupling of high-performance liquid chromatography with ESIMS.

  20. Cochlear microphonic broad tuning curves

    NASA Astrophysics Data System (ADS)

    Ayat, Mohammad; Teal, Paul D.; Searchfield, Grant D.; Razali, Najwani

    2015-12-01

    It is known that the cochlear microphonic voltage exhibits much broader tuning than does the basilar membrane motion. The most commonly used explanation for this is that when an electrode is inserted at a particular point inside the scala media, the microphonic potentials of neighbouring hair cells have different phases, leading to cancelation at the electrodes location. In situ recording of functioning outer hair cells (OHCs) for investigating this hypothesis is exceptionally difficult. Therefore, to investigate the discrepancy between the tuning curves of the basilar membrane and those of the cochlear microphonic, and the effect of phase cancellation of adjacent hair cells on the broadness of the cochlear microphonic tuning curves, we use an electromechanical model of the cochlea to devise an experiment. We explore the effect of adjacent hair cells (i.e., longitudinal phase cancellation) on the broadness of the cochlear microphonic tuning curves in different locations. The results of the experiment indicate that active longitudinal coupling (i.e., coupling with active adjacent outer hair cells) only slightly changes the broadness of the CM tuning curves. The results also demonstrate that there is a π phase difference between the potentials produced by the hair bundle and the soma near the place associated with the characteristic frequency based on place-frequency maps (i.e., the best place). We suggest that the transversal phase cancellation (caused by the phase difference between the hair bundle and the soma) plays a far more important role than longitudinal phase cancellation in the broadness of the cochlear microphonic tuning curves. Moreover, by increasing the modelled longitudinal resistance resulting the cochlear microphonic curves exhibiting sharper tuning. The results of the simulations suggest that the passive network of the organ of Corti determines the phase difference between the hair bundle and soma, and hence determines the sharpness of the

  1. Electrospray Ionization-Induced Protein Unfolding

    NASA Astrophysics Data System (ADS)

    Lin, Hong; Kitova, Elena N.; Johnson, Margaret A.; Eugenio, Luiz; Ng, Kenneth K. S.; Klassen, John S.

    2012-12-01

    Electrospray ionization mass spectrometry (ESI-MS) measurements were performed under a variety of solution conditions on a highly acidic sub-fragment (B3C) of the C-terminal carbohydrate-binding repeat region of Clostridium difficile toxin B, and two mutants (B4A and B4B) containing fewer acidic residues. ESI-MS measurements performed in negative ion mode on aqueous ammonium acetate solutions of B3C at low ionic strength ( I < 80 mM) revealed evidence, based on the measured charge state distribution, of protein unfolding. In contrast, no evidence of unfolding was detected from ESI-MS measurements made in positive ion mode at low I or in either mode at higher I. The results of proton nuclear magnetic resonance and circular dichroism spectroscopy measurements and gel filtration chromatography performed on solutions of B3C under low and high I conditions suggest that the protein exists predominantly in a folded state in neutral aqueous solutions with I > 10 mM. The results of ESI-MS measurements performed on B3C in a series of solutions with high I at pH 5 to 9 rule out the possibility that the structural changes are related to ESI-induced changes in pH. It is proposed that unfolding of B3C, observed in negative mode for solutions with low I, occurs during the ESI process and arises due to Coulombic repulsion between the negatively charged residues and liquid/droplet surface charge. ESI-MS measurements performed in negative ion mode on B4A and B4B also reveal a shift to higher charge states at low I but the magnitude of the changes are smaller than observed for B3C.

  2. Electrospray methodologies for characterization and deposition of nanoparticles

    NASA Astrophysics Data System (ADS)

    Modesto Lopez, Luis Balam

    Electrospray is an aerosolization method that generates highly charged droplets from solutions or suspensions and, after a series of solvent evaporation -- droplet fission cycles, it results in particles carrying multiple charges. Highly charged particles are used in a variety of applications, including particle characterization, thin film deposition, nanopatterning, and inhalation studies among several others. In this work, a soft X-ray photoionization was coupled with an electrospray to obtain monodisperse, singly charged nanoparticles for applications in online size characterization with electrical mobility analysis. Photoionization with the soft X-ray charger enhanced the diffusion neutralization rate of the highly charged bacteriophages, proteins, and solid particles. The effect of nanoparticle surface charge and nanoparticle agglomeration in liquids on the electrospray process was studied experimentally and a modified expression to calculate the effective electrical conductivity of nanosuspensions was proposed. The effective electrical conductivity of TiO2 nanoparticle suspensions is strongly dependent on the electrical double layer and the agglomeration dynamics of the particles; and such dependence is more remarkable in liquids with low ionic strength. TiO2 nanoparticle agglomerates with nearly monodisperse sizes in the nanometer and submicrometer ranges were generated, by electrospraying suspensions with tuned effective electrical conductivity, and used to deposit photocatalytic films for water-splitting. Nanostructured films of iron oxide with uniform distribution of particles over the entire deposition area were formed with an electrospray system. The micro-Raman spectra of the iron oxide films showed that transverse and longitudinal optical modes are highly sensitive to the crystallize size of the electrospray-deposited films. The fabrication of films of natural light-harvesting complexes, with the aim of designing biohybrid photovoltaic devices, was

  3. Increasing Protein Charge State When Using Laser Electrospray Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Karki, Santosh; Flanigan, Paul M.; Perez, Johnny J.; Archer, Jieutonne J.; Levis, Robert J.

    2015-05-01

    Femtosecond (fs) laser vaporization is used to transfer cytochrome c, myoglobin, lysozyme, and ubiquitin from the condensed phase into an electrospray (ES) plume consisting of a mixture of a supercharging reagent, m-nitrobenzyl alcohol ( m-NBA), and trifluoroacetic acid (TFA), acetic acid (AA), or formic acid (FA). Interaction of acid-sensitive proteins like cytochrome c and myoglobin with the highly charged ES droplets resulted in a shift to higher charge states in comparison with acid-stable proteins like lysozyme and ubiquitin. Laser electrospray mass spectrometry (LEMS) measurements showed an increase in both the average charge states (Zavg) and the charge state with maximum intensity (Zmode) for acid-sensitive proteins compared with conventional electrospray ionization mass spectrometry (ESI-MS) under equivalent solvent conditions. A marked increase in ion abundance of higher charge states was observed for LEMS in comparison with conventional electrospray for cytochrome c (ranging from 19+ to 21+ versus 13+ to 16+) and myoglobin (ranging from 19+ to 26+ versus 18+ to 21+) using an ES solution containing m-NBA and TFA. LEMS measurements as a function of electrospray flow rate yielded increasing charge states with decreasing flow rates for cytochrome c and myoglobin.

  4. Internal energy and fragmentation of ions produced in electrospray sources.

    PubMed

    Gabelica, Valérie; De Pauw, Edwin

    2005-01-01

    This review addresses the determination of the internal energy of ions produced by electrospray ionization (ESI) sources, and the influence of the internal energy on analyte fragmentation. A control of the analyte internal energy is crucial for several applications of electrospray mass spectrometry, like structural studies, construction of reproducible and exportable spectral libraries, analysis of non-covalent complexes. Sections II and III summarize the Electrospray mechanisms and source design considerations which are relevant to the problem of internal energy, and Section IV gives an overview of the inter-relationships between ion internal energy, reaction time scale, and analyte fragmentation. In these three sections we tried to make the most important theoretical elements understandable by all ESI users, and their understanding requires a minimal background in physical chemistry. We then present the different approaches used to experimentally determine the ion internal energy, as well as various attempts in modeling the internal energy uptake in electrospray sources. Finally, a tentative comparison between electrospray and other ionization sources is made. As the reader will see, although many reports appeared on the subject, the knowledge in the field of internal energy of ions produced by soft ionization sources is still scarce, because of the complexity of the system, and this is what makes this area of research so interesting. The last section presents some perspectives for future research.

  5. Fabrication of superoleophobic surfaces by mask-assisted electrospray

    NASA Astrophysics Data System (ADS)

    Al-Milaji, Karam Nashwan; Zhao, Hong

    2017-02-01

    Electrospraying technique has been demonstrated to fabricate superhydrophobic surfaces with random hierarchical roughness. Yet, it has never been employed to generate superoleophobic surfaces with patterned multiscale roughness. Here, we report a versatile approach to fabricate superoleophobic surfaces with patterned multiscale roughness using a mask-assisted electrospray technique. Superoleophobic surfaces with random hierarchical roughness by conventional electrospray without mask were also investigated for comparison purposes. Surfaces with patterned multiscale roughness were obtained by focusing the electrosprayed deposition through a mesh mask, followed by overlaying a random hierarchical roughness of electrosprayed SiO2. All the textured surfaces were treated with a low surface energy fluoropolymer to render superhydrophobicity and superoleophobicity. Superior repellency against water and hexadecane (27.5 mN/m) has been demonstrated on the surfaces with random hierarchical roughness and patterned multiscale roughness (contact angles of ∼170° and sliding angles of less than 1°). On the random hierarchical surfaces, the intrinsic re-entrant and multi-tier overhang structures in the SiO2 agglomerates enable non-wetting of low surface tension liquids. While on the surfaces with patterned roughness, the dome shape of micropillars plays a critical role in enabling superoleophobicity. The electric field focusing effect exerted by the mask is verified by COMSOL Multiphysics simulation.

  6. Bio-electrosprayed living composite matrix implanted into mouse models.

    PubMed

    Jayasinghe, Suwan N; Warnes, Gary; Scotton, Chris J

    2011-10-10

    We show that composite de novo structures can be generated using bio-electrosprays. Mouse lung fibroblasts are bio-electrosprayed directly with a biopolymer to form cell-bearing matrices, which are viable even when implanted subcutaneously into murine hosts. Generated cell-bearing matrices are assessed in-vitro and found to undergo all expected cellular behaviour. Subsequent in-vivo studies demonstrate the implanted living matrices integrating as expected with the surrounding microenvironment. The in-vitro and in-vivo studies elucidate and validate the ability for either bio-electrosprays or cell electrospinning to form a desired living architecture for undergoing investigation for repairing, replacing and rejuvenating damaged and/or ageing tissues.

  7. Size and distribution controllable silica microballs fabricated by electrospraying

    NASA Astrophysics Data System (ADS)

    Xu, Bojing; Wu, Pan; Jiang, Qi; Gu, Wenhua

    2015-10-01

    Silica microballs have a wide range of applications in the field of optics, electronics, biotechnology chemical industry, and so on. In this work, a new approach, electrospraying, was used to coat the silica microballs onto the glass substrate, and the coating results were compared to spin-coating and dip-coating. Good microball size control could be achieved using the electrospraying method. X-Ray Diffraction (XRD) results showed that amorphous silica microballs were obtained. From Scanning Electron Microscopy (SEM) images, we can see that uniform microball size was achieved. In general, the results are better than what can be achieved by spin-coating, and comparable to that of dip-coating. However, electrospraying has great potential in mass production, especially for large-area fabrication.

  8. High pressure (>1 atm) electrospray ionization mass spectrometry.

    PubMed

    Chen, Lee Chuin; Mandal, Mridul Kanti; Hiraoka, Kenzo

    2011-03-01

    High pressure electrospray ionization mass spectrometry has been performed by pressurizing a custom made ion source chamber with compressed air to a pressure higher than the atmospheric pressure. The ion source was coupled to a commercial time-of-flight mass spectrometer using a nozzle-skimmer arrangement. The onset voltage for the electrospray of aqueous solution was found to be independent on the operating pressure. The onset voltage for the corona discharge, however, increased with the rise of pressure following the Paschen's law. Thus, besides having more working gas for the desolvation process, gaseous breakdown could also be avoided by pressurizing the ESI ion source with air to an appropriate level. Stable electrospray ionization has been achieved for the sample solution with high surface tension such as pure water in both positive and negative ion modes. Fragmentation of labile compounds during the ionization process could also be reduced by optimizing the operating pressure of the ion source.

  9. The electrospray and its application to targeted drug inhalation.

    PubMed

    Gomez, Alessandro

    2002-12-01

    This review explains the fundamentals of electrostatic spray (electrospray) atomization, with emphasis on operation in the so called cone-jet mode, which produces droplets with a very narrow size distribution. Since the control of droplet size is key to maximizing distal lung deposition, the electrospray should be well-suited to targeted drug inhalation. Electrospray droplets are a few micrometers in diameter, but they originate from a much larger nozzle, which allows nebulization of suspensions without clogging. Also discussed are: the physical principles of the break-up of the liquid ligament; droplet dispersion by Coulombic forces; and the most important scaling law linking the droplet size to liquid flow rate and liquid physical properties. The effects of the most critical of those properties may result in some restrictions on drug formulation. Droplets produced by electrospray are electrically charged, so to prevent electrostatic image forces from causing upper respiratory tract deposition. The charge is neutralized by generating a corona discharge of opposite polarity. Briefly discussed are the main differences between the laboratory systems (with which the electrospray has been quantitatively characterized during research in the past 10 years) and commercial electrospray inhalers under development at BattellePharma. Some remarkable miniaturization has incorporated liquid pump, power supply, breath activation, and dose counter into a palm-size portable device. The maximum flow rates dispersed from these devices are in the range of 8-16 microL/s, which makes them suitable for practical drug inhalation therapy. Fabrication is economically competitive with inexpensive nebulizers. Dramatic improvements in respirable dose efficiency (up to 78% by comparison with commercial metered-dose inhalers and dry powder inhalers) should ensure the commercialization of this promising technology for targeted drug inhalation.

  10. Analysis of multiple types of human cells subsequent to bioprinting with electrospraying technology

    PubMed Central

    Xin, Yu; Chai, Gang; Zhang, Ting; Wang, Xiangsheng; Qu, Miao; Tan, Andy; Bogari, Melia; Zhu, Ming; Lin, Li; Hu, Qingxi; Liu, Yuanyuan; Zhang, Yan

    2016-01-01

    The aim of the present study was to investigate bioprinting with electrospraying technology using multiple types of human cell suspensions as bio-ink, in order to lay the initial foundations for the application of the bioprinting technology in tissue engineering. In the current study, six types of human cells were selected and cultured, including human fibroblasts, human adipose-derived stem cells (hADSCs), human periodontal ligament cells (HPDLCs), adult human retinal pigment epithelial cells (ARPE-19), human umbilical vascular endothelial cells (HUVECs) and human gastric epithelial cell line (GES-1). Each cell type was divided into two groups, the experimental and control group. All the experimental group cells were electrosprayed using an electrospraying printer (voltage, 15 kV; flow rate, 150 µl/min) and collected in a petri dish placed 15 cm away from the needle (needle diameter, 0.5 mm). Subsequently, cell viability was detected by flow cytometry with a Live/Dead Viability kit. In addition, the cell morphological characteristics were observed with a phase-contrast microscope after 6 h of culturing in order to obtain adherent cells, while cell proliferation was analyzed using a Cell Counting Kit-8 assay. The control groups, without printing, were subjected to the same procedures as the experimental groups. The results of the cell viability and proliferation assays indicated a statistically significant difference after printing between the experiments and control groups only for the hADSCs (P<0.05); by contrast, no significant difference was observed in cell viability and proliferation for the other five cell types (P>0.05). In addition, there were no observable differences between all experimental and the control groups at any examined time point in the terms of cell morphological characteristics. In conclusion, bioprinting based on electrospraying technology demonstrated no distinct negative effect on cell vitality, proliferation and morphology in the

  11. Plume collimation for laser ablation electrospray ionization mass spectrometry

    DOEpatents

    Vertes, Akos; Stolee, Jessica A.

    2016-06-07

    In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

  12. Plume collimation for laser ablation electrospray ionization mass spectrometry

    DOEpatents

    Vertes, Akos; Stolee, Jessica A.

    2014-09-09

    In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

  13. Low pressure electrospray ionization system and process for effective transmission of ions

    DOEpatents

    Tang, Keqi [Richland, WA; Page, Jason S [Kennewick, WA; Kelly, Ryan T [West Richland, WA; Smith, Richard D [Richland, WA

    2012-05-08

    Systems and methods that provide up to complete transmission of ions between coupled stages with low effective ion losses. An "interfaceless" electrospray ionization system is further described that operates an electrospray at a reduced pressure such that standard electrospray sample solutions can be directly sprayed into an electrodynamic ion funnel which provides ion focusing and transmission of ions into a mass analyzer. Furthermore, chambers maintained at different pressures can allow for more optimal operating conditions for an electrospray emitter and an ion guide.

  14. Encapsulation of bioactive compound from extracted jasmine flower using β-Cyclodextrin via electrospray

    NASA Astrophysics Data System (ADS)

    Rahmam., S.; Naim., M. N.; Ng., E.; Mokhtar, M. Nn; Abu Bakar, N. F.

    2016-06-01

    The ability of electrospray to encapsulate the bioactive compound extracted from Jasmine flower with β-Cyclodextrion (β-CD) without any thermal-assisted processing was demonstrated in this study. The extraction of Jasmine compound were conducted using sonicator at 70 000 Hz, for 10 minutes and followed by mixing of the filtered compound with β-CD. Then, the mixture was electrosprayed under a stable Taylor cone jet mode at the voltage of 4 - 5 kV, with flow rate of 0.2 ml/hour. The aluminum substrate that used for collecting the deposit was placed at 30 cm from the needle's tip to allow the occurrence of evaporation and droplet fission until the droplet transform to solid particles. Characteristics of solidified bioactive compound from Jasmine flower (non-encapsulated compound) and solidified bioactive compound with β-CD (encapsulated compound) were studied in this work. From SEM images, it can be observed that the particles size distribution of encapsulated compound deposits have better deposition array and did not aggregate with each other compared to the non-encapsulated compound. FE-SEM images of encapsulated compound deposits indicate more solid crystal looks while non-encapsulated compound was obtained in the porous form. The electrospray process in this work has successfully encapsulated the Jasmine compound with β-CD without any thermal-assisted process. The encapsulation occurrence was determined using FTIR analysis. Identical peaks that referred to the β-CD were found on the encapsulated compound demonstrated that most deposits were encapsulated with β-CD.

  15. Novel Erythrocyte-like Graphene Microspheres with High Quality and Mass Production Capability via Electrospray Assisted Self-Assembly

    NASA Astrophysics Data System (ADS)

    Tian, Yayang; Wu, Guan; Tian, Xike; Tao, Xiaoming; Chen, Wei

    2013-11-01

    We report for the first time a novel erythrocyte-like graphene microsphere (ELGMs) which can be produced with high quality and mass production capability via electrospray assisted self-assembly. Through simple electrospray treatment of GO suspension into coagulation bath followed by chemical reduction, large quantity of ELGMs with uniform morphology and size can be obtained with production rate of around 2.4 mg/h. Compared with other 3D structures, the ELGMs have a very interesting structural characteristic of perfect exterior doughnut shape and interior porous network. Accordingly, the as-prepared porous ELGMs exhibit excellent capability for fast and recyclable removal of oil and toxic organic solvents from water, reaching up to 216 times of its weight in absorption efficiency, which is tens of times higher than that of conventional sorbent materials. It is strongly believed that the novel hierarchical graphene structures and synergy among different techniques will lead to more future advances in graphene applications.

  16. The Skipping Rope Curve

    ERIC Educational Resources Information Center

    Nordmark, Arne; Essen, Hanno

    2007-01-01

    The equilibrium of a flexible inextensible string, or chain, in the centrifugal force field of a rotating reference frame is investigated. It is assumed that the end points are fixed on the rotation axis. The shape of the curve, the skipping rope curve or "troposkien", is given by the Jacobi elliptic function sn. (Contains 3 figures.)

  17. Anodic Polarization Curves Revisited

    ERIC Educational Resources Information Center

    Liu, Yue; Drew, Michael G. B.; Liu, Ying; Liu, Lin

    2013-01-01

    An experiment published in this "Journal" has been revisited and it is found that the curve pattern of the anodic polarization curve for iron repeats itself successively when the potential scan is repeated. It is surprising that this observation has not been reported previously in the literature because it immediately brings into…

  18. Simulating Supernova Light Curves

    SciTech Connect

    Even, Wesley Paul; Dolence, Joshua C.

    2016-05-05

    This report discusses supernova light simulations. A brief review of supernovae, basics of supernova light curves, simulation tools used at LANL, and supernova results are included. Further, it happens that many of the same methods used to generate simulated supernova light curves can also be used to model the emission from fireballs generated by explosions in the earth’s atmosphere.

  19. Tornado-Shaped Curves

    ERIC Educational Resources Information Center

    Martínez, Sol Sáez; de la Rosa, Félix Martínez; Rojas, Sergio

    2017-01-01

    In Advanced Calculus, our students wonder if it is possible to graphically represent a tornado by means of a three-dimensional curve. In this paper, we show it is possible by providing the parametric equations of such tornado-shaped curves.

  20. Preparation and characterization of polycaprolactone microspheres by electrospraying

    PubMed Central

    Zhou, Feng-Lei; Hubbard Cristinacce, Penny L.; Eichhorn, Stephen J.; Parker, Geoff J. M.

    2016-01-01

    ABSTRACT The ability to reproducibly produce and effectively collect electrosprayed polymeric microspheres with controlled morphology and size in bulk form is challenging. In this study, microparticles were produced by electrospraying polycaprolactone (PCL) of various molecular weights and solution concentrations in chloroform, and by collecting materials on different substrates. The resultant PCL microparticles were characterized by optical and electron microscopy to investigate the effect of molecular weight, solution concentration, applied voltage, working distance, and flow rate on their morphology and size. The work demonstrates the key role of a moderate molecular weight and/or solution concentration in the formation of spherical PCL particles via an electrospraying process. Increasing the applied voltage was found to produce smaller and more uniform PCL microparticles. There was a relatively low increase in the particle average size with an increase in the working distance and flow rate. Four types of substrates were adopted to collect electrosprayed PCL particles: a glass slide, aluminium foil, liquid bath, and copper wire. Unlike 2D bulk structures collected on the other substrates, a 3D tubular structure of microspheres was formed on the copper wire which could find application in the construction of 3D tumor mimics. PMID:27928195

  1. Electrospray ionization mass spectrometry of pyrimidine base-rubidium complexes.

    PubMed

    Frańska, Magdalena

    2005-01-01

    Nucleobases and alkali metal cations, under electrospray ionisation conditions, tend to form the so-called magic number clusters (unusually stable clusters in comparison with the neighbouring ones). The effect of the ion source parameters, namely cone voltage and desolvation temperature and relative concentrations of thymine and RbCl on the [T5+Rb]+ ion abundance has been studied.

  2. Infrared laser-assisted desorption electrospray ionization mass spectrometry.

    PubMed

    Rezenom, Yohannes H; Dong, Jianan; Murray, Kermit K

    2008-02-01

    We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.

  3. Metal-insulator-metal capacitor using electrosprayed nanoparticles

    NASA Astrophysics Data System (ADS)

    Véliz, Bremnen; Bermejo, Sandra; Coll, Arnau; Castañer, Luis

    2014-07-01

    An electrospray technique has been used to deposit SiO2 nanoparticles as insulator layer of a metal-insulator-metal device. Impedance spectroscopy measurements show that a 4.4 factor increase in capacitance is achieved compared to a continuous dielectric layer of the same permittivity and dimensions.

  4. Desorption electrospray ionization mass spectrometry of intact bacteria

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Desorption electrospray ionization (DESI) mass spectrometry (MS) was used to differentiate 7 bacterial species based on their measured DESI-mass spectral profile. Both Gram positive and Gram negative bacteria were tested and included Escherichia coli, Staphyloccocus aureus, Enterococcus sp., Bordete...

  5. Fundamentals of Biomolecule Analysis by Electrospray Ionization Mass Spectrometry

    ERIC Educational Resources Information Center

    Weinecke, Andrea; Ryzhov, Victor

    2005-01-01

    Electrospray ionization (ESI) is a soft ionization technique that allows transfer of fragile biomolecules directly from solution into the gas phase. An instrumental analysis laboratory experiment is designed that would introduce the students to the ESI technique, major parameters of the ion trap mass spectrometers and some caveats in…

  6. CURVES: curve evolution for vessel segmentation.

    PubMed

    Lorigo, L M; Faugeras, O D; Grimson, W E; Keriven, R; Kikinis, R; Nabavi, A; Westin, C F

    2001-09-01

    The vasculature is of utmost importance in neurosurgery. Direct visualization of images acquired with current imaging modalities, however, cannot provide a spatial representation of small vessels. These vessels, and their branches which show considerable variations, are most important in planning and performing neurosurgical procedures. In planning they provide information on where the lesion draws its blood supply and where it drains. During surgery the vessels serve as landmarks and guidelines to the lesion. The more minute the information is, the more precise the navigation and localization of computer guided procedures. Beyond neurosurgery and neurological study, vascular information is also crucial in cardiovascular surgery, diagnosis, and research. This paper addresses the problem of automatic segmentation of complicated curvilinear structures in three-dimensional imagery, with the primary application of segmenting vasculature in magnetic resonance angiography (MRA) images. The method presented is based on recent curve and surface evolution work in the computer vision community which models the object boundary as a manifold that evolves iteratively to minimize an energy criterion. This energy criterion is based both on intensity values in the image and on local smoothness properties of the object boundary, which is the vessel wall in this application. In particular, the method handles curves evolving in 3D, in contrast with previous work that has dealt with curves in 2D and surfaces in 3D. Results are presented on cerebral and aortic MRA data as well as lung computed tomography (CT) data.

  7. Simultaneous determination of Eleutheroside B and Eleutheroside E in rat plasma by high performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study.

    PubMed

    Ma, Bo; Zhang, Qi; Liu, Yinhui; Li, Jing; Xu, Qiuyu; Li, Xiaotian; Yang, Xiaojing; Yao, Di; Sun, Jingjing; Cui, Guangbo; Ying, Hanjie

    2013-02-15

    Eleutheroside B and Eleutheroside E, two kinds of the major bioactive saponins of Eleutherococcus senticosus, play a pivotal role in biologic activity. In this study, a specific and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry method (HPLC-MS/MS) was developed and validated for simultaneous determination of Eleutheroside B and Eleutheroside E in rat plasma. The analytes were extracted from rat plasma via a simple protein precipitation procedure with methanol and polygonin was used as internal standard. Chromatographic separation was achieved on a C18 column using a gradient elution program with acetonitrile and water containing 0.1% ammonium hydroxide solution as the mobile phase, with a flow rate of 0.2mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode in a negative ion mode via electrospray ionization (ESI). The transition monitored were m/z 371 [M-H](-)→209 for Eleutheroside B, m/z 741[M-H](-)→579 for Eleutheroside E and m/z 389[M-H](-)→277 for internal standard. Linear calibration curves were obtained in the concentration range of 1-2000ng/mL for both (Eleutheroside B and Eleutheroside E), with a lower limit of quantification of 1ng/mL. Extraction recovery was over 80% in plasma. The intra- and inter-day precision (RSD) values were below 12% and accuracy (RE) was -2.80 to 5.70% at three QC levels for both. The assay was successfully applied to study pharmacokinetics behavior in rats after oral and intravenous administration of the single substances (Eleutheroside B and Eleutheroside E). And further research was performed by comparing the difference in pharmacokinetic behavior between the single substances and an aqueous extract of E. senticosus after oral administration. Significant difference in pharmacokinetic characteristics between the single substances and an aqueous extract was found in rat, which would be beneficial for

  8. Ambient Characterization of Synthetic Fibers by Laser Ablation Electrospray Ionization Mass Spectrometry

    PubMed Central

    2017-01-01

    Direct analysis of synthetic fibers under ambient conditions is highly desired to identify the polymer, the finishes applied and irregularities that may compromise its performance and value. In this paper, laser ablation electrospray ionization ion mobility time-of-flight mass spectrometry (LAESI-IMS-TOF-MS) was used for the analysis of synthetic polymers and fibers. The key to this analysis was the absorption of laser light by aliphatic and aromatic nitrogen functionalities in the polymers. Analysis of polyamide (PA) 6, 46, 66, and 12 pellets and PA 6, 66, polyaramid and M5 fibers yielded characteristic fragment ions without any sample pretreatment, enabling their unambiguous identification. Synthetic fibers are, in addition, commonly covered with a surface layer for improved adhesion and processing. The same setup, but operated in a transient infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mode, allowed the detailed characterization of the fiber finish layer and the underlying polymer. Differences in finish layer distribution may cause variations in local properties of synthetic fibers. Here we also show the feasibility of mass spectrometry imaging (MSI) of the distribution of a finish layer on the synthetic fiber and the successful detection of local surface defects. PMID:28252942

  9. An electrospray ionization source for thermochemical investigation with the guided ion beam mass spectrometer.

    PubMed

    Moision, R M; Armentrout, P B

    2007-06-01

    An electrospray ionization (ESI) source developed for use with the guided ion beam tandem mass spectrometer (GIBMS) is described. For accurate determination of thermochemistry using threshold collision-induced dissociation (TCID), it is essential that any source produces ions with four exacting characteristics: (1) high intensity, (2) stable signal, and well-defined energies both (3) kinetic, and (4) internal. To accomplish these objectives, the ions generated by the electrospray are collected using a radio frequency electrodynamic ion funnel and are then transferred into a hexapole ion guide where they are thermalized and subsequently passed into higher-vacuum regions for analysis. The resulting ion intensities using this source can exceed 10(6) ions/s. Stable beams (<10% variation in signal) can be generated over multiple hours. The kinetic energy distribution of ions emerging from this source has been shown to be well described by a Gaussian distribution with a full width half maximum (FWHM) of about 0.1-0.2 eV in the laboratory frame of reference. Finally, TCID results for ions generated with this source show excellent agreement with previously reported threshold values for ions generated using a variety of sources and experimental methodologies. This confirms that internal energies of the ions are well described by a Maxwell-Boltzmann distribution at room temperature.

  10. High-performance liquid chromatography with electrospray ionization ion mobility spectrometry: Characterization, data management, and applications.

    PubMed

    Zühlke, Martin; Riebe, Daniel; Beitz, Toralf; Löhmannsröben, Hans-Gerd; Andreotti, Sandro; Reinert, Knut; Zenichowski, Karl; Diener, Marc

    2016-12-01

    The combination of high-performance liquid chromatography and electrospray ionization ion mobility spectrometry facilitates the two-dimensional separation of complex mixtures in the retention and drift time plane. The ion mobility spectrometer presented here was optimized for flow rates customarily used in high-performance liquid chromatography between 100 and 1500 μL/min. The characterization of the system with respect to such parameters as the peak capacity of each time dimension and of the 2D spectrum was carried out based on a separation of a pesticide mixture containing 24 substances. While the total ion current chromatogram is coarsely resolved, exhibiting coelutions for a number of compounds, all substances can be separately detected in the 2D plane due to the orthogonality of the separations in retention and drift dimensions. Another major advantage of the ion mobility detector is the identification of substances based on their characteristic mobilities. Electrospray ionization allows the detection of substances lacking a chromophore. As an example, the separation of a mixture of 18 amino acids is presented. A software built upon the free mass spectrometry package OpenMS was developed for processing the extensive 2D data. The different processing steps are implemented as separate modules which can be arranged in a graphic workflow facilitating automated processing of data.

  11. Molecular resolution and fragmentation of fulvic acid by electrospray ionization/multistage tandem mass spectrometry

    USGS Publications Warehouse

    Leenheer, J.A.; Rostad, C.E.; Gates, Paul M.; Furlong, E.T.; Ferrer, I.

    2001-01-01

    Molecular weight distributions of fulvic acid from the Suwannee River, Georgia, were investigated by electrospray ionization/quadrupole mass spectrometry (ESI/QMS), and fragmentation pathways of specific fulvic acid masses were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry (ESI/MST/MS). ESI/QMS studies of the free acid form of low molecular weight poly(carboxylic acid) standards in 75% methanol/25% water mobile phase found that negative ion detection gave the optimum generation of parent ions that can be used for molecular weight determinations. However, experiments with poly(acrylic acid) mixtures and specific high molecular weight standards found multiply charged negative ions that gave a low bias to molecular mass distributions. The number of negative charges on a molecule is dependent on the distance between charges. ESI/MST/MS of model compounds found characteristic water loss from alcohol dehydration and anhydride formation, as well as CO2 loss from decarboxylation, and CO loss from ester structures. Application of these fragmentation pathways to specific masses of fulvic acid isolated and fragmented by ESI/MST/MS is indicative of specific structures that can serve as a basis for future structural confirmation after these hypothesized structures are synthesized.

  12. Metal Cationization Extractive Electrospray Ionization Mass Spectrometry of Compounds Containing Multiple Oxygens.

    PubMed

    Swanson, Kenneth D; Spencer, Sandra E; Glish, Gary L

    2016-11-28

    Extractive electrospray ionization is an ambient ionization technique that allows real-time sampling of liquid samples, including organic aerosols. Similar to electrospray ionization, the composition of the electrospray solvent used in extractive electrospray ionization can easily be altered to form metal cationized molecules during ionization simply by adding a metal salt to the electrospray solvent. An increase in sensitivity is observed for some molecules that are lithium, sodium, or silver cationized compared with the protonated molecule formed in extractive electrospray ionization with an acid additive. Tandem mass spectrometry of metal cationized molecules can also significantly improve the ability to identify a compound. Tandem mass spectrometry of lithium and silver cationized molecules can result in an increase in the number and uniqueness of dissociation pathways relative to [M + H](+). These results highlight the potential for extractive electrospray ionization with metal cationization in analyzing complex aerosol mixtures. Graphical Abstract ᅟ.

  13. Metal Cationization Extractive Electrospray Ionization Mass Spectrometry of Compounds Containing Multiple Oxygens

    NASA Astrophysics Data System (ADS)

    Swanson, Kenneth D.; Spencer, Sandra E.; Glish, Gary L.

    2016-11-01

    Extractive electrospray ionization is an ambient ionization technique that allows real-time sampling of liquid samples, including organic aerosols. Similar to electrospray ionization, the composition of the electrospray solvent used in extractive electrospray ionization can easily be altered to form metal cationized molecules during ionization simply by adding a metal salt to the electrospray solvent. An increase in sensitivity is observed for some molecules that are lithium, sodium, or silver cationized compared with the protonated molecule formed in extractive electrospray ionization with an acid additive. Tandem mass spectrometry of metal cationized molecules can also significantly improve the ability to identify a compound. Tandem mass spectrometry of lithium and silver cationized molecules can result in an increase in the number and uniqueness of dissociation pathways relative to [M + H]+. These results highlight the potential for extractive electrospray ionization with metal cationization in analyzing complex aerosol mixtures.

  14. International transferability of accident modification functions for horizontal curves.

    PubMed

    Elvik, Rune

    2013-10-01

    Studies of the relationship between characteristics of horizontal curves and accident rate have been reported in several countries. The characteristic most often studied is the radius of a horizontal curve. Functions describing the relationship between the radius of horizontal curves and accident rate have been developed in Australia, Canada, Denmark, Germany, Great Britain, New Zealand, Norway, Portugal, Sweden, and the United States. Other characteristics of horizontal curves that have been studied include deflection angle, curve length, the presence of transition curves, super-elevation in curves and distance to adjacent curves. This paper assesses the international transferability of mathematical functions (accident modification functions) that have been developed to relate the radius of horizontal curves to their accident rate. The main research problem is whether these functions are similar, which enhances international transferability, or dissimilar, which reduces international transferability. Accident modification functions for horizontal curve radius developed in the countries listed above are synthesised. The sensitivity of the functions to other characteristics of curves than radius is examined. Accident modification functions developed in different countries have important similarities. The functions diverge with respect to accident rate in the sharpest curves.

  15. Mechanics of Curved Folds

    NASA Astrophysics Data System (ADS)

    Dias, Marcelo A.; Santangelo, Christian D.

    2011-03-01

    Despite an almost two thousand year history, origami, the art of folding paper, remains a challenge both artistically and scientifically. Traditionally, origami is practiced by folding along straight creases. A whole new set of shapes can be explored, however, if, instead of straight creases, one folds along arbitrary curves. We present a mechanical model for curved fold origami in which the energy of a plastically-deformed crease is balanced by the bending energy of developable regions on either side of the crease. Though geometry requires that a sheet buckle when folded along a closed curve, its shape depends on the elasticity of the sheet. NSF DMR-0846582.

  16. Fabrication of internally tapered capillaries for capillary electrochromatography electrospray ionization mass spectrometry.

    PubMed

    Zheng, Jack; Norton, Dean; Shamsi, Shahab A

    2006-02-15

    In this study, we report a novel procedure for fabricating internally tapered capillary columns suitable for the coupling of capillary electrochromatography (CEC) to electrospray mass spectrometry (ESI-MS). The internal tapers were prepared by slowly heating the capillary end in a methane/O2 flame. Due to continuous self-shrinking of the inner channel of the capillary, the inside diameter of the opening was reduced to 7-10 microm. The procedure is easy to handle, with no requirement for expensive equipment as well as elimination of problematic grinding of the tip. Several advantages of these new internal tapers, as compared to using externally tapered columns, are described. First, the problems of poor durability and tip breakage associated with external tapering were successfully overcome with the internal taper. A comparison of the online CEC/ESI-MS between external versus internal tapers showed that the latter provides enhanced electrospray stability, resulting in significantly lower short-term noise and very short-term noise values. In turn, the more rugged design of internal tapers allows performing CEC/MS utilizing a harsh polar organic mobile phase, which was not previously successful using an external taper due to higher operating current and electrospray arcing. Next, data on the reproducibility of the internally tapered CEC/MS column using warfarin and beta-blockers as model analytes are presented. For example, when comparing the reproducibility for separation of warfarin under reversed-phase conditions, the internal taper demonstrated superior intraday % RSD (1.6-3.4) as compared to the external taper intraday % RSD (5-6). Last, the applicability of performing quantitative CEC/MS with internally tapered capillaries is demonstrated for simultaneous enantioseparation of beta-blockers. Impressive quantitative results include good linearity of calibration curves (e.g., R2 = 0.9940-0.9988) and limit of detection as low as 30 nM. The sensitive detection of a

  17. Search for liquids electrospraying the smallest possible nanodrops in vacuo

    NASA Astrophysics Data System (ADS)

    Alonso-Matilla, R.; Fernández-García, J.; Congdon, H.; Fernández de la Mora, J.

    2014-12-01

    Prior work with electrosprays in vacuum of mixtures of ionic liquids (ILs) and the moderately high boiling point (Tb) solvents formamide (FM) and propylene carbonate (PC) (Tb of 210 and 241 °C) has shown that the charged drops produced have reasonably narrow charge/mass distributions, controllable over a wide mass/charge range. This enables their use as propellants in electrical propulsion with specific impulse Isp varying from a few hundred to a few thousand seconds (10 kV beam energy) and with excellent propulsion efficiency. However, some limitations are imposed by the finite room temperature volatility of FM and PC. Here, we seek improved performance from propellants based on the polar but viscous solvent Sulfolane (SF; ɛ = 43.2, μ = 10.3 cP) and the low viscosity but less polar solvent tributyl phosphate (TBP; ɛ = 8.9, μ = 3.4 cP), both with Tb > 280 °C. Neither TBP nor its low viscosity mixtures with SF achieve the electrical conductivities needed to yield high Isp. Most ILs used in SF/IL mixtures tested were based on the 1-ethyl-3-methylimidazolium (EMI) or 1,3-dimethylimidazolium (DMI) cations, including EMI-BF4, EMI-N(CN)2, and DMI-N(CN)2. These combinations reach high conductivities, some approaching 3 S/m, but have limited propulsive performance because evaporation of ions directly from the electrified meniscus produces undesirable mixed beams of drops and ions. Exceptional characteristics are found in mixtures of SF with ethylammonium nitrate (EAN), where the small EA+ cation is strongly bound to the solvent, greatly delaying ion evaporation from the meniscus. Evidence on the formation of nano-jets with diameters as small as 1 nm is seen. Although unprecedented, this finding agrees with what would be expected if ion evaporation were suppressed. SF/EAN mixtures thus provide the best available sources to produce the smallest possible nanodrops, minimally polluted by ions.

  18. Search for liquids electrospraying the smallest possible nanodrops in vacuo

    SciTech Connect

    Alonso-Matilla, R.; Fernández-García, J.; Congdon, H.; Fernández de la Mora, J.

    2014-12-14

    Prior work with electrosprays in vacuum of mixtures of ionic liquids (ILs) and the moderately high boiling point (T{sub b}) solvents formamide (FM) and propylene carbonate (PC) (T{sub b} of 210 and 241 °C) has shown that the charged drops produced have reasonably narrow charge/mass distributions, controllable over a wide mass/charge range. This enables their use as propellants in electrical propulsion with specific impulse I{sub sp} varying from a few hundred to a few thousand seconds (10 kV beam energy) and with excellent propulsion efficiency. However, some limitations are imposed by the finite room temperature volatility of FM and PC. Here, we seek improved performance from propellants based on the polar but viscous solvent Sulfolane (SF; ε = 43.2, μ = 10.3 cP) and the low viscosity but less polar solvent tributyl phosphate (TBP; ε = 8.9, μ = 3.4 cP), both with T{sub b} > 280 °C. Neither TBP nor its low viscosity mixtures with SF achieve the electrical conductivities needed to yield high I{sub sp}. Most ILs used in SF/IL mixtures tested were based on the 1-ethyl-3-methylimidazolium (EMI) or 1,3-dimethylimidazolium (DMI) cations, including EMI-BF{sub 4}, EMI-N(CN){sub 2}, and DMI-N(CN){sub 2}. These combinations reach high conductivities, some approaching 3 S/m, but have limited propulsive performance because evaporation of ions directly from the electrified meniscus produces undesirable mixed beams of drops and ions. Exceptional characteristics are found in mixtures of SF with ethylammonium nitrate (EAN), where the small EA{sup +} cation is strongly bound to the solvent, greatly delaying ion evaporation from the meniscus. Evidence on the formation of nano-jets with diameters as small as 1 nm is seen. Although unprecedented, this finding agrees with what would be expected if ion evaporation were suppressed. SF/EAN mixtures thus provide the best available sources to produce the smallest possible nanodrops, minimally polluted by

  19. Thin-Layer Chromatography/Desorption Electrospray Ionization Mass Spectrometry: Investigation of Goldenseal Alkaloids

    SciTech Connect

    Van Berkel, Gary J; Tomkins, Bruce A; Kertesz, Vilmos

    2007-01-01

    Desorption electrospray ionization mass spectrometry was investigated as a means to qualitatively identify and to quantify analytes directly from developed normal-phase thin layer chromatography plates. The atmospheric sampling capillary of a commercial ion trap mass spectrometer was extended to permit sampling and ionization of analytes in bands separated on intact TLC plates (up to 10 cm x 10 cm). A surface positioning software package and the appropriate hardware enabled computer-controlled surface scanning along the length of development lanes or at fixed RF value across the plates versus the stationary desorption electrospray emitter. Goldenseal (Hydrastis canadensis) and related alkaloids and commercial dietary supplements were used as standards and samples. Alkaloid standards and samples were spotted and separated on aluminum- or glass-backed plates using established literature methods. The mass spectral signal levels as a function of desorption spray solvent were investigated with acetonitrile proving superior to methanol. The detection levels (ca. 5 ng each or 14 -28 pmol) in mass spectral full scan mode were determined statistically from the calibration curves (2.5 - 100 pmol) for the standards berberine, palmatine and hydrastinine spotted as a mixture and separated on the plates. Qualitative screening of the major alkaloids present in six different over-the-counter "goldenseal" dietary supplements was accomplished by obtaining full scan mass spectra during surface scans along the development lane in the direction of increasing RF value. In one sample, alkaloids were detected that strongly suggested the presence of at least one additional herb undeclared on the product label. These same data indicated the misidentification of one of the alkaloids in the TLC literature. Quantities of the alkaloids present in two of the samples determined using the mass spectral data were in reasonable agreement with the label values indicating the quantitative ability of

  20. Linear instability of curved free shear layers

    NASA Technical Reports Server (NTRS)

    Liou, William W.

    1993-01-01

    The linear inviscid hydrodynamic stability of slightly curved free mixing layers is studied in this paper. The disturbance equation is solved numerically using a shooting technique. Two mean velocity profiles that represent stably and unstably curved free mixing layers are considered. Results are shown for cases of five curvature Richardson numbers. The stability characteristics of the shear layer are found to vary significantly with the introduction of the curvature effects. The results also indicate that, in a manner similar to the Goertler vortices observed in a boundary layer along a concave wall, instability modes of spatially developing streamwise vortex pairs may appear in centrifugally unstable curved mixing layers.

  1. Are driving and overtaking on right curves more dangerous than on left curves?

    PubMed

    Othman, Sarbaz; Thomson, Robert; Lannér, Gunnar

    2010-01-01

    that drivers behave differently depending on the curve direction where both speed and acceleration were higher on right than left curves. The implication of this study is that curve direction should be taken into consideration to a greater extent when designing and redesigning curves. It appears that the driver and the vehicle are influenced by different infrastructure factors depending on the curve direction. In addition, the results suggest that the vehicle dynamics response alone cannot explain the higher crash risk in right curves. Further studies of the links between driver, vehicle, and highway characteristics are needed, such as naturalistic driving studies, to identify the key safety indicators for highway safety.

  2. Examination of Bacterial Characteristics of Anaerobic Membrane Bioreactors in Three Pilot-Scale Plants for Treating Low-Strength Wastewater by Application of the Colony-Forming-Curve Analysis Method

    PubMed Central

    Kataoka, Naoaki; Tokiwa, Yutaka; Tanaka, Yasuo; Fujiki, Kiichi; Taroda, Hiroyuki; Takeda, Kiyoshi

    1992-01-01

    Characteristic sludge ecosystems arising in anaerobic membrane bioreactors of three pilot-scale plants treating low-strength (less than 1 g of biological oxygen demand per liter) sewage or soybean-processing wastewater were examined by analysis of the colony-forming-curves (CFC) obtained by counting colonies at suitable intervals. The wastewaters, containing high amounts of suspended solids (SS) (SS/chemical oxygen demand ratio, 0.51 to 0.80), were treated by using two types of bioreactors: (i) a hydrolyzation reactor for solubilization and acidification of SS in wastewater and (ii) a methane fermentation reactor for producing methane. The colony counts for the two sewage treatment plants continued to increase even after 3 weeks of incubation, whereas those for soybean-processing wastewater reached an approximately constant level within 3 weeks of incubation. The CFCs were analyzed by correlating the rate of colony appearance on roll tubes with the physiological types of bacteria present in the bioreactors. It was found that there were large numbers of slow-colony-forming anaerobic bacteria within the bioreactors and that the viable populations consisted of a few groups with different growth rates. It is considered that the slow-growing colonies appearing after 10 days of incubation were the dominant microflora in the sewage treated by hydrolyzation reactors. In particular, highly concentrated sludge (30.0 g of mixed-liquor volatile SS per liter) retained by the membrane separation module contained a large number of such bacteria. Slow-growing colonies of these bacteria could be counted by using a sludge extract medium prepared from only the supernatant of autoclaved sludge. In addition, the highest colony counts were almost always obtained with the sludge extract medium, meaning that most of the anaerobic bacteria in these sludges have complex nutrient requirements for growth. This report also indicates the usefulness of application of the CFC analysis method to

  3. Curved centerline air intake for a gas turbine engine

    NASA Technical Reports Server (NTRS)

    Ruehr, W. C.; Younghans, J. L.; Smith, E. B. (Inventor)

    1980-01-01

    An inlet for a gas turbine engine was disposed about a curved centerline for the purpose of accepting intake air that is flowing at an angle to engine centerline and progressively turning that intake airflow along a curved path into alignment with the engine. This curved inlet is intended for use in under the wing locations and similar regions where airflow direction is altered by aerodynamic characteristics of the airplane. By curving the inlet, aerodynamic loss and acoustic generation and emission are decreased.

  4. Electrosprayed inulin microparticles for microbiota triggered targeting of colon.

    PubMed

    Jain, Arvind K; Sood, Vishesh; Bora, Meghali; Vasita, Rajesh; Katti, Dhirendra S

    2014-11-04

    Inulin, a naturally occurring polysaccharide, was acetylated to make it processable by electrospraying, a facile and single step method for microparticle fabrication. Electrospraying process parameters were optimized for fabrication of spherical and monodisperse indomethacin (IDM) loaded inulin acetate (INA) microparticles. The apparent entrapment efficiency of IDM was determined to be 100%, whereas working encapsulation efficiency was estimated to be 35.39 ± 1.63%. Differential scanning calorimetry and X-ray diffraction analysis confirmed molecular dispersion of IDM in an amorphous state within the INA matrix. Finally, the results from in vitro release study performed in simulated gastro-intestinal fluids demonstrated that IDM was released only in simulated colonic fluid that contained inulinase. Therefore, this study demonstrates that acetylation of inulin does not alter its susceptibility to inulinase and that microparticles fabricated from INA can be developed as a colon targeting drug delivery system.

  5. Hydration of Gas-Phase Ions Formed by Electrospray Ionization

    PubMed Central

    Rodriguez-Cruz, Sandra E.; Klassen, John S.; Williams, Evan R.

    2005-01-01

    The hydration of gas-phase ions produced by electrospray ionization was investigated. Evidence that the hydrated ions are formed by two mechanisms is presented. First, solvent condensation during the expansion inside the electrospray source clearly occurs. Second, some solvent evaporation from more extensively solvated ions or droplets is apparent. To the extent that these highly solvated ions have solution-phase structures, then the final isolated gas-phase structure of the ion will be determined by the solvent evaporation process. This process was investigated for hydrated gramicidin S in a Fourier-transform mass spectrometer. Unimolecular dissociation rate constants of isolated gramicidin S ions with between 2 and 14 associated water molecules were measured. These rate constants increased from 16 to 230 s−1 with increasing hydration, with smaller values corresponding to magic numbers. PMID:10497808

  6. Sampling probe for microarray read out using electrospray mass spectrometry

    DOEpatents

    Van Berkel, Gary J.

    2004-10-12

    An automated electrospray based sampling system and method for analysis obtains samples from surface array spots having analytes. The system includes at least one probe, the probe including an inlet for flowing at least one eluting solvent to respective ones of a plurality of spots and an outlet for directing the analyte away from the spots. An automatic positioning system is provided for translating the probe relative to the spots to permit sampling of any spot. An electrospray ion source having an input fluidicly connected to the probe receives the analyte and generates ions from the analyte. The ion source provides the generated ions to a structure for analysis to identify the analyte, preferably being a mass spectrometer. The probe can be a surface contact probe, where the probe forms an enclosing seal along the periphery of the array spot surface.

  7. Electrospray on superhydrophobic nozzles treated with argon and oxygen plasma

    NASA Astrophysics Data System (ADS)

    Byun, Doyoung; Lee, Youngjong; Tran, Si Bui Quang; Nugyen, Vu Dat; Kim, Sanghoon; Park, Baeho; Lee, Sukhan; Inamdar, Niraj; Bau, Haim H.

    2008-03-01

    We report on a simple process to fabricate electrohydrodynamic spraying devices with superhydrophobic nozzles. These devices are useful, among other things, in mass spectrometry and printing technology. The superhydrophobic nozzle is created by roughening the surface of the polyfluorotetraethylene (PTFE) by argon and oxygen plasma treatment. We have developed a polymer-based electrospray device with a flat, superhydrophobic nozzle capable of maintaining a high contact angle and stable jetting.

  8. Capillary isoelectric focusing-electrospray mass spectrometry for protein analysis

    SciTech Connect

    Tang, Q.; Harrata, A.K.; Lee, C.S.

    1995-10-01

    On-line combination of capillary isoelectric focusing (CIEF) with electrospray mass spectrometry (ESMS) as a two-dimensional separation system is demonstrated. Mixtures of model proteins including cytochrome c (horse heart), myoglobin (horse heart), and carbonic anhydrase II (bovine erythrocyte) are focused and cathodically mobilized in a polyacrylamide-coated capillary. At the end of CIEF capillary, the mobilized protein zones are analyzed by mass spectrometry coupled on-line to an electrospray interface with a coaxial sheath flow configuration. The effects of carrier ampholyte concentration on the CIEF separation and the protein electrospray ionization mass spectra are presented and discussed. In this study, the focusing effect of CIEF permits analysis of very dilute protein samples. A typical concentration factor of 50-100 times is observed. The concentration detection limit of myoglobin for a full-scan CIEF-ESMS analysis is in the range of 10{sup -7} M, 2 orders of magnitude over that possible with normal capillary zone electrophoresis ESMS. 35 refs., 5 figs., 2 tabs.

  9. Fast quantitative detection of cocaine in beverages using nanoextractive electrospray ionization tandem mass spectrometry.

    PubMed

    Hu, Bin; Peng, Xuejiao; Yang, Shuiping; Gu, Haiwei; Chen, Huanwen; Huan, Yanfu; Zhang, Tingting; Qiao, Xiaolin

    2010-02-01

    Without any sample pretreatment, effervescent beverage fluids were manually sprayed into the primary ion plume created by using a nanoelectrospray ionization source for direct ionization, and the analyte ions of interest were guided into an ion trap mass spectrometer for tandem mass analysis. Functional ingredients (e.g., vitamins, taurine, and caffeine, etc.) and spiked impurity (e.g., cocaine) in various beverages, such as Red Bull energy drink, Coco-cola, and Pepsi samples were rapidly identified within 1.5 s. The limit of detection was found to be 7-15 fg (S/N = 3) for cocaine in different samples using the characteristic fragment (m/z 150) observed in the MS(3) experiments. Typical relative standard deviation and recovery of this method were 6.9%-8.6% and 104%-108% for direct analysis of three actual samples, showing that nanoextractive electrospray ionization tandem mass spectrometry is a useful technique for fast screening cocaine presence in beverages.

  10. The Scanning Mass Spectrometry Probe: A Scanning Probe Electrospray Ion Source for Imaging Mass Spectrometry of Submerged Interfaces and Transient Events in Solution

    PubMed Central

    Kottke, Peter A.; Degertekin, F. Levent; Fedorov, Andrei G.

    2009-01-01

    The scanning mass spectrometry (SMS) probe is new electrospray ion source. Motivated by the need for untargeted chemical imaging of dynamic events in solution, we have exploited an approach to electrospray ionization (ESI) that allows continuous sampling from a highly localized volume (~picoliters) in a liquid environment, softly ionizes molecules in the sample to render them amenable for mass spectrometric analysis, and sends the ions to the mass spectrometer. The key underlying concepts for our approach are1)Treating the electrospray capillary inlet as a chemical scanning probe, and2)Locating the electrospray point as close as possible to the sampling point, thus providing the shortest response time possible. This approach enables chemical monitoring or imaging of submerged interfaces, providing access to details of spatial heterogeneity and temporal changes within liquid samples. It also permits direct access to liquid/ liquid interfaces for ESI-MS analysis. In this Letter we report the first demonstrations of these capabilities of the SMS probe, and describe some of the probe's basic characteristics. PMID:19904914

  11. The sales learning curve.

    PubMed

    Leslie, Mark; Holloway, Charles A

    2006-01-01

    When a company launches a new product into a new market, the temptation is to immediately ramp up sales force capacity to gain customers as quickly as possible. But hiring a full sales force too early just causes the firm to burn through cash and fail to meet revenue expectations. Before it can sell an innovative product efficiently, the entire organization needs to learn how customers will acquire and use it, a process the authors call the sales learning curve. The concept of a learning curve is well understood in manufacturing. Employees transfer knowledge and experience back and forth between the production line and purchasing, manufacturing, engineering, planning, and operations. The sales learning curve unfolds similarly through the give-and-take between the company--marketing, sales, product support, and product development--and its customers. As customers adopt the product, the firm modifies both the offering and the processes associated with making and selling it. Progress along the manufacturing curve is measured by tracking cost per unit: The more a firm learns about the manufacturing process, the more efficient it becomes, and the lower the unit cost goes. Progress along the sales learning curve is measured in an analogous way: The more a company learns about the sales process, the more efficient it becomes at selling, and the higher the sales yield. As the sales yield increases, the sales learning process unfolds in three distinct phases--initiation, transition, and execution. Each phase requires a different size--and kind--of sales force and represents a different stage in a company's production, marketing, and sales strategies. Adjusting those strategies as the firm progresses along the sales learning curve allows managers to plan resource allocation more accurately, set appropriate expectations, avoid disastrous cash shortfalls, and reduce both the time and money required to turn a profit.

  12. Liquid chromatography/electrospray ionization tandem mass spectrometry assay for determination of nicotine and metabolites, caffeine and arecoline in breast milk.

    PubMed

    Pellegrini, Manuela; Marchei, Emilia; Rossi, Silvia; Vagnarelli, Federica; Durgbanshi, Abhilasha; García-Algar, Oscar; Vall, Oriol; Pichini, Simona

    2007-01-01

    A procedure based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) is described for the determination of nicotine and its principal metabolites cotinine, trans-3-hydroxycotinine and cotinine-N-oxide, caffeine and arecoline in breast milk, using N-ethylnorcotinine as internal standard. Liquid/liquid extraction with chloroform/isopropanol (95:5, v/v) was used for nicotine, cotinine, trans-3-hydroxycotinine, cotinine-N-oxide and caffeine under neutral conditions and for arecoline under basic conditions. Chromatography was performed on a C(8) reversed-phase column using a gradient of 50 mM ammonium formate, pH 5.0, and acetonitrile as a mobile phase at a flow rate of 0.5 mL/min. Separated analytes were determined by electrospray ionization tandem mass spectrometry in the positive ion mode using multiple reaction monitoring. Limits of quantification were 5 microg/L for nicotine, cotinine, trans-3-hydroxycotinine, cotinine-N-oxide and caffeine, and 50 microg/L for arecoline using 1 mL human milk per assay. Calibration curves were linear over the calibration ranges for all the substances under investigation, with a minimum r(2) > 0.998. At three concentrations spanning the linear dynamic range of the assay, mean recoveries from breast milk ranged between 71.8 and 77.4% for different analytes. This method was applied to the analysis of analytes in human milk to assess substance exposure in breast-fed infants in relation to eventual clinical outcomes. This LC/MS/MS assay provides adequate sensitivity and performance characteristics for the simultaneous quantification of biomarkers of three of the drugs most commonly used worldwide (tobacco, caffeine and areca nut).

  13. Classification of ASKAP Vast Radio Light Curves

    NASA Technical Reports Server (NTRS)

    Rebbapragada, Umaa; Lo, Kitty; Wagstaff, Kiri L.; Reed, Colorado; Murphy, Tara; Thompson, David R.

    2012-01-01

    The VAST survey is a wide-field survey that observes with unprecedented instrument sensitivity (0.5 mJy or lower) and repeat cadence (a goal of 5 seconds) that will enable novel scientific discoveries related to known and unknown classes of radio transients and variables. Given the unprecedented observing characteristics of VAST, it is important to estimate source classification performance, and determine best practices prior to the launch of ASKAP's BETA in 2012. The goal of this study is to identify light curve characterization and classification algorithms that are best suited for archival VAST light curve classification. We perform our experiments on light curve simulations of eight source types and achieve best case performance of approximately 90% accuracy. We note that classification performance is most influenced by light curve characterization rather than classifier algorithm.

  14. Determination of equilibrium association constants of ligand-DNA complexes by electrospray mass spectrometry.

    PubMed

    Gabelica, Valérie

    2010-01-01

    Electrospray mass spectrometry can be used to detect ligand-DNA noncovalent complexes formed in solution. This chapter describes how to determine equilibrium association constants of the complexes. Particular attention is devoted to describing how to tune an electrospray mass spectrometer using a 12-mer oligodeoxynucleotides duplex in order to perform these experiments. This protocol can then be applied to any nucleic acid structure that can be ionized with electrospray mass spectrometry.

  15. Low pressure electrospray ionization system and process for effective transmission of ions

    DOEpatents

    Tang, Keqi; Page, Jason S.; Kelly, Ryan T.; Smith, Richard D.

    2010-03-02

    A system and method are disclosed that provide up to complete transmission of ions between coupled stages with low effective ion losses. A novel "interfaceless" electrospray ionization system is further described that operates the electrospray at a reduced pressure such that standard electrospray sample solutions can be directly sprayed into an electrodynamic ion funnel which provides ion focusing and transmission of ions into a mass analyzer.

  16. Graphing Polar Curves

    ERIC Educational Resources Information Center

    Lawes, Jonathan F.

    2013-01-01

    Graphing polar curves typically involves a combination of three traditional techniques, all of which can be time-consuming and tedious. However, an alternative method--graphing the polar function on a rectangular plane--simplifies graphing, increases student understanding of the polar coordinate system, and reinforces graphing techniques learned…

  17. Textbook Factor Demand Curves.

    ERIC Educational Resources Information Center

    Davis, Joe C.

    1994-01-01

    Maintains that teachers and textbook graphics follow the same basic pattern in illustrating changes in demand curves when product prices increase. Asserts that the use of computer graphics will enable teachers to be more precise in their graphic presentation of price elasticity. (CFR)

  18. Curve Fit Challenge

    ERIC Educational Resources Information Center

    Harper, Suzanne R.; Driskell, Shannon

    2005-01-01

    Graphic tips for using the Geometer's Sketchpad (GSP) are described. The methods to import an image into GSP, define a coordinate system, plot points and curve fit the function using a graphical calculator are demonstrated where the graphic features of GSP allow teachers to expand the use of the technology application beyond the classroom.

  19. The Bacterial Growth Curve.

    ERIC Educational Resources Information Center

    Paulton, Richard J. L.

    1991-01-01

    A procedure that allows students to view an entire bacterial growth curve during a two- to three-hour student laboratory period is described. Observations of the lag phase, logarithmic phase, maximum stationary phase, and phase of decline are possible. A nonpathogenic, marine bacterium is used in the investigation. (KR)

  20. Comparison of Internal Energy Distributions of Ions Created by Electrospray Ionization and Laser Ablation-Liquid Vortex Capture-Electrospray Ionization

    SciTech Connect

    Cahill, John F.; Kertesz, Vilmos; Ovchinnikova, Olga S.; Van Berkel, Gary J.

    2015-06-27

    Recently a number of techniques have combined laser ablation with liquid capture for mass spectrometry spot sampling and imaging applications. The newly developed non-contact liquid-vortex capture probe has been used to efficiently collect 355 nm UV laser ablated material in a continuous flow solvent stream in which the captured material dissolves and then undergoes electrospray ionization. This sampling and ionization approach has produced what appear to be classic electrospray ionization spectra; however, the softness of this sampling/ionization process versus simple electrospray ionization has not been definitely determined. A series of benzlypyridinium salts, known as thermometer ions, were used to compare internal energy distributions between electrospray ionization and the UV laser ablation liquid-vortex capture probe electrospray combination. Measured internal energy distributions were identical between the two techniques, even with differences in laser fluence (0.7-3.1 J cm-2) and when using UV-absorbing or non-UV-absorbing sample substrates. This data indicates ions formed directly by UV laser ablation, if any, are likely an extremely small constituent of the total ion signal observed. Instead, neutral molecules, clusters or particulates ejected from the surface during laser ablation, subsequently captured and dissolved in the flowing solvent stream then electrosprayed are the predominant source of ion signal observed. The electrospray ionization process used controls the softness of the technique.

  1. Comparison of Internal Energy Distributions of Ions Created by Electrospray Ionization and Laser Ablation-Liquid Vortex Capture-Electrospray Ionization

    DOE PAGES

    Cahill, John F.; Kertesz, Vilmos; Ovchinnikova, Olga S.; ...

    2015-06-27

    Recently a number of techniques have combined laser ablation with liquid capture for mass spectrometry spot sampling and imaging applications. The newly developed non-contact liquid-vortex capture probe has been used to efficiently collect 355 nm UV laser ablated material in a continuous flow solvent stream in which the captured material dissolves and then undergoes electrospray ionization. This sampling and ionization approach has produced what appear to be classic electrospray ionization spectra; however, the softness of this sampling/ionization process versus simple electrospray ionization has not been definitely determined. A series of benzlypyridinium salts, known as thermometer ions, were used to comparemore » internal energy distributions between electrospray ionization and the UV laser ablation liquid-vortex capture probe electrospray combination. Measured internal energy distributions were identical between the two techniques, even with differences in laser fluence (0.7-3.1 J cm-2) and when using UV-absorbing or non-UV-absorbing sample substrates. This data indicates ions formed directly by UV laser ablation, if any, are likely an extremely small constituent of the total ion signal observed. Instead, neutral molecules, clusters or particulates ejected from the surface during laser ablation, subsequently captured and dissolved in the flowing solvent stream then electrosprayed are the predominant source of ion signal observed. The electrospray ionization process used controls the softness of the technique.« less

  2. Nonlinear Growth Curves in Developmental Research

    ERIC Educational Resources Information Center

    Grimm, Kevin J.; Ram, Nilam; Hamagami, Fumiaki

    2011-01-01

    Developmentalists are often interested in understanding change processes, and growth models are the most common analytic tool for examining such processes. Nonlinear growth curves are especially valuable to developmentalists because the defining characteristics of the growth process such as initial levels, rates of change during growth spurts, and…

  3. Trishear for curved faults

    NASA Astrophysics Data System (ADS)

    Brandenburg, J. P.

    2013-08-01

    Fault-propagation folds form an important trapping element in both onshore and offshore fold-thrust belts, and as such benefit from reliable interpretation. Building an accurate geologic interpretation of such structures requires palinspastic restorations, which are made more challenging by the interplay between folding and faulting. Trishear (Erslev, 1991; Allmendinger, 1998) is a useful tool to unravel this relationship kinematically, but is limited by a restriction to planar fault geometries, or at least planar fault segments. Here, new methods are presented for trishear along continuously curved reverse faults defining a flat-ramp transition. In these methods, rotation of the hanging wall above a curved fault is coupled to translation along a horizontal detachment. Including hanging wall rotation allows for investigation of structures with progressive backlimb rotation. Application of the new algorithms are shown for two fault-propagation fold structures: the Turner Valley Anticline in Southwestern Alberta, and the Alpha Structure in the Niger Delta.

  4. Atlas of fatigue curves

    SciTech Connect

    Boyer, H.E.

    1986-01-01

    This Atlas was developed to serve engineers who are looking for fatigue data on a particular metal or alloy. Having these curves compiled in a single book will also facilitate the computerization of the involved data. It is pointed out that plans are under way to make the data in this book available in ASCII files for analysis by computer programs. S-N curves which typify effects of major variables are considered along with low-carbon steels, medium-carbon steels, alloy steels, HSLA steels, high-strength alloy steels, heat-resisting steels, stainless steels, maraging steels, cast irons, and heat-resisting alloys. Attention is also given to aluminum alloys, copper alloys, magnesium alloys, molybdenum, tin alloys, titanium and titanium alloys, zirconium, steel castings, closed-die forgings, powder metallurgy parts, composites, effects of surface treatments, and test results for component parts.

  5. Miniature curved artificial compound eyes

    PubMed Central

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L’Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A.; Franceschini, Nicolas

    2013-01-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories. PMID:23690574

  6. Miniature curved artificial compound eyes.

    PubMed

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L'Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A; Franceschini, Nicolas

    2013-06-04

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories.

  7. Mouse Curve Biometrics

    SciTech Connect

    Schulz, Douglas A.

    2007-10-08

    A biometric system suitable for validating user identity using only mouse movements and no specialized equipment is presented. Mouse curves (mouse movements with little or no pause between them) are individually classied and used to develop classication histograms, which are representative of an individual's typical mouse use. These classication histograms can then be compared to validate identity. This classication approach is suitable for providing continuous identity validation during an entire user session.

  8. Quantization on Curves

    NASA Astrophysics Data System (ADS)

    Frønsdal, Christian; Kontsevich, Maxim

    2007-02-01

    Deformation quantization on varieties with singularities offers perspectives that are not found on manifolds. The Harrison component of Hochschild cohomology, vanishing on smooth manifolds, reflects information about singularities. The Harrison 2-cochains are symmetric and are interpreted in terms of abelian *-products. This paper begins a study of abelian quantization on plane curves over mathbb{C}, being algebraic varieties of the form {mathbb{C}}^2/R, where R is a polynomial in two variables; that is, abelian deformations of the coordinate algebra mathbb{C}[x,y]/(R). To understand the connection between the singularities of a variety and cohomology we determine the algebraic Hochschild (co)homology and its Barr Gerstenhaber Schack decomposition. Homology is the same for all plane curves mathbb{C}[x,y]/R, but the cohomology depends on the local algebra of the singularity of R at the origin. The Appendix, by Maxim Kontsevich, explains in modern mathematical language a way to calculate Hochschild and Harrison cohomology groups for algebras of functions on singular planar curves etc. based on Koszul resolutions.

  9. Numerical simulation of electrospray in the cone-jet mode.

    PubMed

    Herrada, M A; López-Herrera, J M; Gañán-Calvo, A M; Vega, E J; Montanero, J M; Popinet, S

    2012-08-01

    We present a robust and computationally efficient numerical scheme for simulating steady electrohydrodynamic atomization processes (electrospray). The main simplification assumed in this scheme is that all the free electrical charges are distributed over the interface. A comparison of the results with those calculated with a volume-of-fluid method showed that the numerical scheme presented here accurately describes the flow pattern within the entire liquid domain. Experiments were performed to partially validate the numerical predictions. The simulations reproduced accurately the experimental shape of the liquid cone jet, providing correct values of the emitted electric current even for configurations very close to the cone-jet stability limit.

  10. Microscale extraction of perchlorate in drinking water with low level detection by electrospray-mass spectrometry.

    PubMed

    Magnuson, M L; Urbansky, E T; Kelty, C A

    2000-06-21

    Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking water. Perchlorate in drinking water has been determined at sub-mug l(-1) levels by extraction of the ion-pair formed between the perchlorate ion and a cationic surfactant with electrospray-mass spectrometry detection. Confidence in the selective quantification of the perchlorate ion is increased through both the use of the mass based detection as well as the selectivity of the ion pair. This study investigates several extraction solvents and experimental work-up procedures in order to achieve high sample throughput. The method detection limit for perchlorate based on 3.14sigma(n-1) of seven replicate injections was 300 ng l(-1) (parts-per-trillion) for methylene chloride extraction and 270 ng l(-1) for methyl isobutyl ketone extraction. Extraction with methylene chloride produces linear calibration curves, enabling standard addition to be used to quantify perchlorate in drinking water. Perchlorate determination of a contaminated water compared favorably with results determined by ion chromatography.

  11. Studying the chemistry of cationized triacylglycerols using electrospray ionization mass spectrometry and density functional theory computations.

    PubMed

    Grossert, J Stuart; Cubero Herrera, Lisandra; Ramaley, Louis; Melanson, Jeremy E

    2014-08-01

    Analysis of triacylglycerols (TAGs), found as complex mixtures in living organisms, is typically accomplished using liquid chromatography, often coupled to mass spectrometry. TAGs, weak bases not protonated using electrospray ionization, are usually ionized by adduct formation with a cation, including those present in the solvent (e.g., Na(+)). There are relatively few reports on the binding of TAGs with cations or on the mechanisms by which cationized TAGs fragment. This work examines binding efficiencies, determined by mass spectrometry and computations, for the complexation of TAGs to a range of cations (Na(+), Li(+), K(+), Ag(+), NH4(+)). While most cations bind to oxygen, Ag(+) binding to unsaturation in the acid side chains is significant. The importance of dimer formation, [2TAG + M](+) was demonstrated using several different types of mass spectrometers. From breakdown curves, it became apparent that two or three acid side chains must be attached to glycerol for strong cationization. Possible mechanisms for fragmentation of lithiated TAGs were modeled by computations on tripropionylglycerol. Viable pathways were found for losses of neutral acids and lithium salts of acids from different positions on the glycerol moiety. Novel lactone structures were proposed for the loss of a neutral acid from one position of the glycerol moiety. These were studied further using triple-stage mass spectrometry (MS(3)). These lactones can account for all the major product ions in the MS(3) spectra in both this work and the literature, which should allow for new insights into the challenging analytical methods needed for naturally occurring TAGs.

  12. Studying the Chemistry of Cationized Triacylglycerols Using Electrospray Ionization Mass Spectrometry and Density Functional Theory Computations

    NASA Astrophysics Data System (ADS)

    Grossert, J. Stuart; Herrera, Lisandra Cubero; Ramaley, Louis; Melanson, Jeremy E.

    2014-08-01

    Analysis of triacylglycerols (TAGs), found as complex mixtures in living organisms, is typically accomplished using liquid chromatography, often coupled to mass spectrometry. TAGs, weak bases not protonated using electrospray ionization, are usually ionized by adduct formation with a cation, including those present in the solvent (e.g., Na+). There are relatively few reports on the binding of TAGs with cations or on the mechanisms by which cationized TAGs fragment. This work examines binding efficiencies, determined by mass spectrometry and computations, for the complexation of TAGs to a range of cations (Na+, Li+, K+, Ag+, NH4 +). While most cations bind to oxygen, Ag+ binding to unsaturation in the acid side chains is significant. The importance of dimer formation, [2TAG + M]+ was demonstrated using several different types of mass spectrometers. From breakdown curves, it became apparent that two or three acid side chains must be attached to glycerol for strong cationization. Possible mechanisms for fragmentation of lithiated TAGs were modeled by computations on tripropionylglycerol. Viable pathways were found for losses of neutral acids and lithium salts of acids from different positions on the glycerol moiety. Novel lactone structures were proposed for the loss of a neutral acid from one position of the glycerol moiety. These were studied further using triple-stage mass spectrometry (MS3). These lactones can account for all the major product ions in the MS3 spectra in both this work and the literature, which should allow for new insights into the challenging analytical methods needed for naturally occurring TAGs.

  13. Piecewise power laws in individual learning curves.

    PubMed

    Donner, Yoni; Hardy, Joseph L

    2015-10-01

    The notion that human learning follows a smooth power law (PL) of diminishing gains is well-established in psychology. This characteristic is observed when multiple curves are averaged, potentially masking more complex dynamics underpinning the curves of individual learners. Here, we analyzed 25,280 individual learning curves, each comprising 500 measurements of cognitive performance taken from four cognitive tasks. A piecewise PL (PPL) model explained the individual learning curves significantly better than a single PL, controlling for model complexity. The PPL model allows for multiple PLs connected at different points in the learning process. We also explored the transition dynamics between PL curve component pieces. Performance in later pieces typically surpassed that in earlier pieces, after a brief drop in performance at the transition point. The transition rate was negatively associated with age, even after controlling for overall performance. Our results suggest at least two processes at work in individual learning curves: locally, a gradual, smooth improvement, with diminishing gains within a specific strategy, which is modeled well as a PL; and globally, a discrete sequence of strategy shifts, in which each strategy is better in the long term than the ones preceding it. The piecewise extension of the classic PL of practice has implications for both individual skill acquisition and theories of learning.

  14. Vapor Pressure of Hexamethylene Triperoxide Diamine (HMTD) Estimated Using Secondary Electrospray Ionization Mass Spectrometry.

    PubMed

    Aernecke, Matthew J; Mendum, Ted; Geurtsen, Geoff; Ostrinskaya, Alla; Kunz, Roderick R

    2015-11-25

    A rapid method for vapor pressure measurement was developed and used to derive the vapor pressure curve of the thermally labile peroxide-based explosive hexamethylene triperoxide diamine (HMTD) over the temperature range from 28 to 80 °C. This method uses a controlled flow of vapor from a solid-phase HMTD source that is presented to an ambient-pressure-ionization mass spectrometer equipped with a secondary-electrospray-ionization (SESI) source. The subpart-per-trillion sensitivity of this system enables direct detection of HMTD vapor through an intact [M + H](+) ion in real time at temperatures near 20 °C. By calibrating this method using vapor sources of cocaine and heroin, which have known pressure-temperature (P-T) curves, the temperature dependence of HMTD vapor was determined, and a Clausius-Clapeyron plot of ln[P (Pa)] vs 1/[T (K)] yielded a straight line with the expression ln[P (Pa)] = {(-11091 ± 356) × 1/[T (K)]} + 25 ± 1 (error limits are the standard error of the regression analysis). From this equation, the sublimation enthalpy of HMTD was estimated to be 92 ± 3 kJ/mol, which compares well with the theoretical estimate of 95 kJ/mol, and the vapor pressure at 20 °C was estimated to be ∼60 parts per trillion by volume, which is within a factor of 2 of previous theoretical estimates. Thus, this method provides not only the first direct experimental determination of HMTD vapor pressure but also a rapid, near-real-time capability to quantitatively measure low-vapor-pressure compounds, which will be useful for aiding in the development of training aids for bomb-sniffing canines.

  15. Brush potential curve tracer

    DOEpatents

    Finch, H.A.

    1985-06-21

    A device for analyzing commutating characteristics of a motor or generator includes a holder for supporting a plurality of probes adjacent a brush of the motor or generator. Measurements of electrical current characteristics of the probes provides information useful in analyzing operation of the machine. Methods for employing a device in accordance with the invention are also disclosed.

  16. Desorption electrospray ionization-mass spectrometric analysis of low vapor pressure chemical particulates collected from a surface.

    PubMed

    Ewing, K J; Gibson, D; Sanghera, J; Miklos, F

    2015-01-01

    The collection of a low vapor pressure chemical simulant triethyl phosphate sorbed onto silica gel (TEP/SG) from a surface with subsequent analysis of the TEP/SG particulates using desorption electrospray ionization-mass spectrometry (DESI-MS) is described. Collection of TEP/SG particulates on a surface was accomplished using a sticky screen sampler composed of a stainless steel screen coated with partially polymerized polydimethylsiloxane (PDMS). DESI-MS analysis of TEP/SG particulates containing different percentages of TEP sorbed onto silica gel enabled the generation of response curves for the TEP ions m/z 155 and m/z 127. Using the response curves the calculation of the mass of TEP in a 25 wt% sample of TEP/SG was calculated, results show that the calculated mass of TEP was 14% different from the actual mass of TEP in the sample using the m/z 127 TEP ion response curve. Detection limits for the TEP vapor and TEP/SG particulates were calculated to be 4 μg and 6 particles, respectively.

  17. Rotation Curves of Galaxies

    NASA Astrophysics Data System (ADS)

    Kalnajs, Agris J.

    One can obtain a fairly good understanding of the relation between axially symmetric mass distributions and the rotation curves they produce without resorting to calculations. However it does require a break with tradition. The first step consists of replacing quantities such as surface density, volume density, and circular velocity with the mass in a ring, mass in a spherical shell, and the square of the circular velocity, or more precisely with 2 pi G r mu(r), 4 pi G r^2 rho(r), and Vc^2 (r). These three quantities all have the same dimensions, and are related to each other by scale-free linear operators. The second step consists of introducing ln(r) as the coordinate. On the log scale the scale-free operators becomes the more familiar convolution operations. Convolutions are easily handled by Fourier techniques and a surface density can be converted into a rotation curve or volume density in a small fraction of a second. A simple plot of 2 pi G r mu(r) as a function of ln(r) reveals the relative contributions of different radii to Vc^2(r). Such a plot also constitutes a sanity test for the fitting of various laws to photometric data. There are numerous examples in the literature of excellent fits to the tails that lack data or are poor fits around the maximum of 2 pi G r mu(r). I will discuss some exact relations between the above three quantities as well as some empirical observations such as the near equality of the maxima of 2 pi G r mu(r) and Vc^2 (r) curves for flat mass distributions.

  18. Curved PVDF airborne transducer.

    PubMed

    Wang, H; Toda, M

    1999-01-01

    In the application of airborne ultrasonic ranging measurement, a partially cylindrical (curved) PVDF transducer can effectively couple ultrasound into the air and generate strong sound pressure. Because of its geometrical features, the ultrasound beam angles of a curved PVDF transducer can be unsymmetrical (i.e., broad horizontally and narrow vertically). This feature is desired in some applications. In this work, a curved PVDF air transducer is investigated both theoretically and experimentally. Two resonances were observed in this transducer. They are length extensional mode and flexural bending mode. Surface vibration profiles of these two modes were measured by a laser vibrometer. It was found from the experiment that the surface vibration was not uniform along the curvature direction for both vibration modes. Theoretical calculations based on a model developed in this work confirmed the experimental results. Two displacement peaks were found in the piezoelectric active direction of PVDF film for the length extensional mode; three peaks were found for the flexural bending mode. The observed peak positions were in good agreement with the calculation results. Transient surface displacement measurements revealed that vibration peaks were in phase for the length extensional mode and out of phase for the flexural bending mode. Therefore, the length extensional mode can generate a stronger ultrasound wave than the flexural bending mode. The resonance frequencies and vibration amplitudes of the two modes strongly depend on the structure parameters as well as the material properties. For the transducer design, the theoretical model developed in this work can be used to optimize the ultrasound performance.

  19. Magnetism in curved geometries

    NASA Astrophysics Data System (ADS)

    Streubel, Robert; Fischer, Peter; Kronast, Florian; Kravchuk, Volodymyr P.; Sheka, Denis D.; Gaididei, Yuri; Schmidt, Oliver G.; Makarov, Denys

    2016-09-01

    Extending planar two-dimensional structures into the three-dimensional space has become a general trend in multiple disciplines, including electronics, photonics, plasmonics and magnetics. This approach provides means to modify conventional or to launch novel functionalities by tailoring the geometry of an object, e.g. its local curvature. In a generic electronic system, curvature results in the appearance of scalar and vector geometric potentials inducing anisotropic and chiral effects. In the specific case of magnetism, even in the simplest case of a curved anisotropic Heisenberg magnet, the curvilinear geometry manifests two exchange-driven interactions, namely effective anisotropy and antisymmetric exchange, i.e. Dzyaloshinskii-Moriya-like interaction. As a consequence, a family of novel curvature-driven effects emerges, which includes magnetochiral effects and topologically induced magnetization patterning, resulting in theoretically predicted unlimited domain wall velocities, chirality symmetry breaking and Cherenkov-like effects for magnons. The broad range of altered physical properties makes these curved architectures appealing in view of fundamental research on e.g. skyrmionic systems, magnonic crystals or exotic spin configurations. In addition to these rich physics, the application potential of three-dimensionally shaped objects is currently being explored as magnetic field sensorics for magnetofluidic applications, spin-wave filters, advanced magneto-encephalography devices for diagnosis of epilepsy or for energy-efficient racetrack memory devices. These recent developments ranging from theoretical predictions over fabrication of three-dimensionally curved magnetic thin films, hollow cylinders or wires, to their characterization using integral means as well as the development of advanced tomography approaches are in the focus of this review.

  20. Magnetism in curved geometries

    SciTech Connect

    Streubel, Robert; Fischer, Peter; Kronast, Florian; Kravchuk, Volodymyr P.; Sheka, Denis D.; Gaididei, Yuri; Schmidt, Oliver G.; Makarov, Denys

    2016-08-17

    Extending planar two-dimensional structures into the three-dimensional space has become a general trend in multiple disciplines, including electronics, photonics, plasmonics and magnetics. This approach provides means to modify conventional or to launch novel functionalities by tailoring the geometry of an object, e.g. its local curvature. In a generic electronic system, curvature results in the appearance of scalar and vector geometric potentials inducing anisotropic and chiral effects. In the specific case of magnetism, even in the simplest case of a curved anisotropic Heisenberg magnet, the curvilinear geometry manifests two exchange-driven interactions, namely effective anisotropy and antisymmetric exchange, i.e. Dzyaloshinskii–Moriya-like interaction. As a consequence, a family of novel curvature-driven effects emerges, which includes magnetochiral effects and topologically induced magnetization patterning, resulting in theoretically predicted unlimited domain wall velocities, chirality symmetry breaking and Cherenkov-like effects for magnons. The broad range of altered physical properties makes these curved architectures appealing in view of fundamental research on e.g. skyrmionic systems, magnonic crystals or exotic spin configurations. In addition to these rich physics, the application potential of three-dimensionally shaped objects is currently being explored as magnetic field sensorics for magnetofluidic applications, spin-wave filters, advanced magneto-encephalography devices for diagnosis of epilepsy or for energy-efficient racetrack memory devices. Finally, these recent developments ranging from theoretical predictions over fabrication of three-dimensionally curved magnetic thin films, hollow cylinders or wires, to their characterization using integral means as well as the development of advanced tomography approaches are in the focus of this review.

  1. Magnetism in curved geometries

    DOE PAGES

    Streubel, Robert; Fischer, Peter; Kronast, Florian; ...

    2016-08-17

    Extending planar two-dimensional structures into the three-dimensional space has become a general trend in multiple disciplines, including electronics, photonics, plasmonics and magnetics. This approach provides means to modify conventional or to launch novel functionalities by tailoring the geometry of an object, e.g. its local curvature. In a generic electronic system, curvature results in the appearance of scalar and vector geometric potentials inducing anisotropic and chiral effects. In the specific case of magnetism, even in the simplest case of a curved anisotropic Heisenberg magnet, the curvilinear geometry manifests two exchange-driven interactions, namely effective anisotropy and antisymmetric exchange, i.e. Dzyaloshinskii–Moriya-like interaction. Asmore » a consequence, a family of novel curvature-driven effects emerges, which includes magnetochiral effects and topologically induced magnetization patterning, resulting in theoretically predicted unlimited domain wall velocities, chirality symmetry breaking and Cherenkov-like effects for magnons. The broad range of altered physical properties makes these curved architectures appealing in view of fundamental research on e.g. skyrmionic systems, magnonic crystals or exotic spin configurations. In addition to these rich physics, the application potential of three-dimensionally shaped objects is currently being explored as magnetic field sensorics for magnetofluidic applications, spin-wave filters, advanced magneto-encephalography devices for diagnosis of epilepsy or for energy-efficient racetrack memory devices. Finally, these recent developments ranging from theoretical predictions over fabrication of three-dimensionally curved magnetic thin films, hollow cylinders or wires, to their characterization using integral means as well as the development of advanced tomography approaches are in the focus of this review.« less

  2. Complementary Curves of Descent

    DTIC Science & Technology

    2012-11-16

    provision of law , no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid...curves of descent 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT...NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES) US Naval Academy,Physics Department,Annapolis,MD,21402-1363 8. PERFORMING ORGANIZATION

  3. Curved cap corrugated sheet

    NASA Technical Reports Server (NTRS)

    Davis, R. C.; Bales, T. T.; Royster, D. M.; Jackson, L. R. (Inventor)

    1984-01-01

    The report describes a structure for a strong, lightweight corrugated sheet. The sheet is planar or curved and includes a plurality of corrugation segments, each segment being comprised of a generally U-shaped corrugation with a part-cylindrical crown and cap strip, and straight side walls and with secondary corrugations oriented at right angles to said side walls. The cap strip is bonded to the crown and the longitudinal edge of said cap strip extends beyond edge at the intersection between said crown and said side walls. The high strength relative to weight of the structure makes it desirable for use in aircraft or spacecraft.

  4. Transferability of the Electrospray Ionization Efficiency Scale between Different Instruments

    NASA Astrophysics Data System (ADS)

    Liigand, Jaanus; Kruve, Anneli; Liigand, Piia; Laaniste, Asko; Girod, Marion; Antoine, Rodolphe; Leito, Ivo

    2015-11-01

    For the first time, quantitative electrospray (ESI) ionization efficiencies (IE), expressed as log IE values, obtained on different mass-spectrometric setups (four mass analyzers and four ESI sources) are compared for 15 compounds of diverse properties. The general trends of change of IE with molecular structure are the same with all experimental setups. The obtained IE scales could be applied on different setups: there were no statistically significant changes in the order of ionization efficiency and the root mean of squared differences of the log IE values of compounds between the scales compiled on different instruments were found to be between 0.21 and 0.55 log units. The results show that orthogonal ESI source geometry gives better differentiating power and additional pneumatic assistance improves it even more. It is also shown that the ionization efficiency values are transferable between different mass-spectrometric setups by three anchoring points and a linear model. The root mean square error of log IE prediction ranged from 0.24 to 0.72 depending on the instrument. This work demonstrates for the first time the inter-instrument transferability of quantitative electrospray ionization efficiency data.

  5. Unexpected Analyte Oxidation during Desorption Electrospray Ionization - Mass Spectrometry

    SciTech Connect

    Pasilis, Sofie P; Kertesz, Vilmos; Van Berkel, Gary J

    2008-01-01

    During the analysis of surface spotted analytes using desorption electrospray ionization mass spectrometry (DESI-MS), abundant ions are sometimes observed that appear to be the result of oxygen addition reactions. In this investigation, the effect of sample aging, the ambient lab environment, spray voltage, analyte surface concentration, and surface type on this oxidative modification of spotted analytes, exemplified by tamoxifen and reserpine, during analysis by desorption electrospray ionization mass spectrometry was studied. Simple exposure of the samples to air and to ambient lighting increased the extent of oxidation. Increased spray voltage lead also to increased analyte oxidation, possibly as a result of oxidative species formed electrochemically at the emitter electrode or in the gas - phase by discharge processes. These oxidative species are carried by the spray and impinge on and react with the sampled analyte during desorption/ionization. The relative abundance of oxidized species was more significant for analysis of deposited analyte having a relatively low surface concentration. Increasing spray solvent flow rate and addition of hydroquinone as a redox buffer to the spray solvent were found to decrease, but not entirely eliminate, analyte oxidation during analysis. The major parameters that both minimize and maximize analyte oxidation were identified and DESI-MS operational recommendations to avoid these unwanted reactions are suggested.

  6. A Corona Discharge Initiated Electrochemical Electrospray Ionization Technique

    PubMed Central

    Lloyd, John R.; Hess, Sonja

    2009-01-01

    We report here the development of a corona discharge (CD) initiated electrochemical (EC) electrospray ionization (ESI) technique using a standard electrospray ion source. This is a new ionization technique distinct from ESI, electrochemistry inherent to ESI, APCI, and techniques using hydroxyl radicals produced under atmospheric pressure conditions. By maximizing the observable CD at the tip of a stainless steel ESI capillary, efficient electrochemical oxidation of electrochemically active compounds is observed. For electrochemical oxidation to be observed, the ionization potential of the analyte must be lower than Fe. Ferrocene labeled compounds were chosen as the electrochemically active moiety. The electrochemical cell in the ESI source was robust and generated ions with selectivity according to the ionization potential of the analytes and up to zeptomolar sensitivity. Our results indicate that CD initiated electrochemical ionization has the potential to become a powerful technique to increase the dynamic range, sensitivity and selectivity of ESI experiments. Synopsis Using a standard ESI source a corona discharge initiated electrochemical ionization technique was established resulting from the electrochemistry occurring at the CD electrode surface. PMID:19747843

  7. Targeting Sessile Droplets with Electrospray to Form Nanoparticle Deposits

    NASA Astrophysics Data System (ADS)

    Chiarot, Paul; Daeumer, Matthias; Maktabi, Sepehr; Yong, Xin

    2016-11-01

    The ability to print ordered deposits of nanoparticles has significant implications for electronics and photonics manufacturing. In this work, electrospray atomization was used to deliver dry nanoparticles to the surface of sacrificial sessile droplets. The particles were subsequently mapped to a glass substrate upon complete evaporation of the target droplet to create a deposit. The influence of the key electrospray operating parameters on the final deposit structure were explored, including: spray time, nanoparticle concentration, and initial sacrificial droplet volume. Once the nanoparticles were delivered to the interface, evaporatively-driven transport of the particles across the surface of the sessile droplet played a significant role in determining the structure of the deposit. When the contact line of the target sessile droplet was pinned during evaporation, the final deposit had greater particle density at the edge and center. The particles were distributed more uniformly across the deposit when the contact line of the target droplet moved during evaporation. The influence of thermal gradients on the final deposit structure was investigated by heating the substrate to increase the sessile droplet temperature. We also conducted computational simulations of evaporating particle-laden droplets and explored the influences of contact line behavior and nanoparticle surface chemistry on the deposit structure. This research supported by the National Science Foundation (Award 1538090).

  8. Analysis of metal-EDTA complexes by electrospray mass spectrometry

    SciTech Connect

    Baron, D.; Hering, J.G.

    1998-07-01

    Solutions of the strong complexing agent ethylenediaminetetraacetic acid (EDTA) and Cu, Pb, Cd, Al, and Fe(III) were examined by electrospray mass spectrometry (ES/MS). Uncomplexed EDTA and metal-EDTA complexes survive the electrospray process intact and can be detected simultaneously by mass spectrometry. Best sensitivity was achieved in the positive ion mode in which EDTA and EDTA-metal complexes (present in solution as anions) were detected as protonated species with a single positive charge. Except for the protonation, the aqueous metal-EDTA complexes are preserved and neither fragmentation of complexes nor formation of clusters with more than one metal or ligand were observed in the mass spectra. Detection limits are between approximately 1 to 2 {micro}M for uncomplexed EDTA and for the Cu-EDTA and Pb-EDTA complexes, with a linear range up to 10{sup {minus}4} M. Calibrations based on solutions with equimolar concentrations of EDTA and Cu or Pb can be used to quantify EDTA-metal complexes in solutions with excess EDTA or metal, and in solutions with more than one metal present. Isotopic signatures of metals in the metal-ligand complexes are preserved, allowing the identification of the metal in a metal-ligand complex. Isotopic signatures of metals can therefore aid in the identification of metal-ligand complexes in unknown samples.

  9. Electrospray Ionization Mass Spectrometry of hexanitrohexaazaisowurtzitane (CL-20)

    SciTech Connect

    Campbell, James A.; Szecsody, Jim E.; Devary, Brooks J.; Valenzuela, Blandina R.

    2007-09-03

    Hexanitrohexaazaisowurtzitane, (C6H6N12O12, MW 438) {CL-20}, is a high-energy propellent that has been recently developed and successfully tested (Nielsen et al. 1998). CL-20 releases more energy on ignition and is more stable to accidental detonation than currently used energetic materials. It is expected to replace many of the energetic materials currently being used by the Department of Defense (DoD). The EPA method 8330 (EPA 1997) for the analysis of explosives and metabolites in soils calls for the use of UV/Vis detection. High performance liquid chromatography has been used to quantify CL-20 and precursor concentration (Bazaki et al. 1998`) at relatively high concentrations. Fourier transform infrared (FTIR) spectroscopy has been used to identify different crystal forms of CL-20 (4 isomers; Kim et al. 1998). Campbell et al. (1997) utilized particle beam mass spectrometry for the analysis of enzymatic degradation of explosives. Introduction and recent improvements of ionization techniques such as electrospray (ES) have allowed the mass spectrometer to become more widely used in liquid chromatography. Schilling(1996) also examined explosive components and metabolites using electrospray (ES) and atmospheric pressure chemical ionization (APCI) liquid chromatography/mass spectrometry (LC/MS). Schilling’s results showed that compared to thermospray LC/MS, APCI and ES were more sensitive than thermospray by at least an order of magnitude. 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX), 10 nitroso-RDX metabolites, and other munitions in ground water have been analyzed using solid phase extraction and isotope dilution liquid chromatography-APCI mass spectrometry (Cassada et al. 1999). The method detection limits indicate that nitramine and nitroaromatic compounds can be routinely determined in ground water samples using electrospray LC/MS with concentration techniques utilizing solid-phase extraction. Miller et al. (1996) studied nitrated explosives with mobile phase

  10. Transforming Curves into Curves with the Same Shape.

    ERIC Educational Resources Information Center

    Levine, Michael V.

    Curves are considered to have the same shape when they are related by a similarity transformation of a certain kind. This paper extends earlier work on parallel curves to curves with the same shape. Some examples are given more or less explicitly. A generalization is used to show that the theory is ordinal and to show how the theory may be applied…

  11. The effect of small cations on the positive electrospray responses of proteins at low pH.

    PubMed

    Pan, Peng; McLuckey, Scott A

    2003-10-15

    Solutions consisting of protein and small molecule mixtures have been subjected to electrospray ionization to study the influence of small molecule/cation components at high concentrations on the electrospray responses of proteins. Emphasis was placed on solutions consisting of equal parts methanol and water and containing 1 vol % acetic acid. The results, therefore, are relevant to low pH solutions with significant organic content, a commonly used set of conditions in electrospray ionization mass spectrometry that tends to denature proteins. A variety of small cations/molecules were selected to sample a range of chemical characteristics. For example, sodium and cesium cations were studied to represent metal ions, tetrabutylammonium and tetramethylammonium cations were studied to represent quaternary ammonium compounds with different surface activities, and octadecylamine and glycine were studied to represent species that compete for protons but have different surface activities. A methodology for measuring relative ion suppression efficiencies was developed and applied for protein ions derived from bovine cytochrome c. The form of the small cation (i.e., metal ion, quaternary ammonium ion, or protonated molecule) did not appear to be a factor in determining the efficiency with which protein ion signals were suppressed. The extent to which ions are expected to concentrate on the surface, however, was the major factor in determining the ion suppression efficiency. Itwas found that the ion suppression efficiency of the most surface active species in this study was comparable to that of a protein on another protein after normalization by charge. These results are particularly relevant to the development of mixture analysis strategies based on ionization and tandem mass spectrometry applied to mixtures of whole proteins.

  12. Online antioxidant activity and ultra-performance LC-electrospray ionisation-quadrupole time-of-fight mass spectrometry for chemical fingerprinting of Indian polyherbal formulations.

    PubMed

    Bhandari, Pamita; Kumar, Neeraj; Khan, Shahid M; Bhutani, Kamlesh K

    2016-01-01

    A HPLC-DAD-DPPH method was developed for evaluating the 1, 1-diphenyl-2-picryl hydrazyl free radical scavenging activity of ethylacetate extracts of different polyherbal formulations (draksarista, draksava, lohasava and arvindasava) by using RP-18e column. The ethylacetate extract from polyherbal, 'draksarista' exhibited maximum free radical scavenging activity (99.9 ± 0.38%) followed by draksava (99.8 ± 0.34%), lohasava (98.5 ± 0.30%) and arvindasava (42.3 ± 0.34%) at 100 μg mL(-1). Simultaneously, ultra-performance liquid chromatography coupled with electrospray ionisation-quadrupole time-of-flight mass spectrometry (UPLC-ESI-QTOF-MS) was used to study chemical composition of the ethylacetate extracts of formulations. The characteristic electrospray mass ionisation reveals the dominance of polyphenols and their glycosides in the four polyherbal formulations.

  13. Multiple CubicBezier Curves.

    ERIC Educational Resources Information Center

    Khonsari, Michael M.; Horn, Douglas

    1990-01-01

    An algorithm is described for generating smooth curves of first-order continuity. The algorithm is composed of several cubic Bezier curves joined together at the user defined control points. Introduced is a tension control parameter which can be set thus providing additional flexibility in the design of free-form curves. (KR)

  14. Titration Curves: Fact and Fiction.

    ERIC Educational Resources Information Center

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  15. Chiral differentiation of the noscapine and hydrastine stereoisomers by electrospray ionization tandem mass spectrometry.

    PubMed

    Nagy, Tibor; Kuki, Ákos; Antal, Borbála; Nagy, Lajos; Purgel, Mihály; Sipos, Attila; Nagy, Miklós; Zsuga, Miklós; Kéki, Sándor

    2015-01-01

    Energy-dependent collision-induced dissociation (CID) of the dimers [2 M + Cat](+) of the noscapine and hydrastine stereoisomers was studied where Cat stands for Li(+), Na(+), K(+) and Cs(+) ions. These dimers were generated 'in situ' from the electrosprayed solution. The survival yield (SY) method was used for distinguishing the noscapine and hydrastine dimers. Significant differences were found between the characteristic collision energies (CE50, i.e. the collision energy necessary to obtain 50% fragmentation) of the homo- (R,R; S,S) and heterochiral (R,S; S,R) stereoisomers. To distinguish the enantiomer pairs L-, D-tyrosine ([M + Tyr + Cat](+)) and L-, D-lysine ([M + Lys + Cat](+)) were used as chiral selectors. Furthermore, these heterodimers [M + amino acid + Cat](+) were also applied to determine the stereoisomeric composition. It was found that the characteristic collision energy (CE50) of the noscapine and hydrastine homodimers ([2 M + Cat](+)) was inversely proportional to the ionic radius of the cations. Furthermore, the structures of the dimers [2 M + Cat](+) were studied by high level quantum chemical calculations.

  16. Quantum relative Lorenz curves

    NASA Astrophysics Data System (ADS)

    Buscemi, Francesco; Gour, Gilad

    2017-01-01

    The theory of majorization and its variants, including thermomajorization, have been found to play a central role in the formulation of many physical resource theories, ranging from entanglement theory to quantum thermodynamics. Here we formulate the framework of quantum relative Lorenz curves, and show how it is able to unify majorization, thermomajorization, and their noncommutative analogs. In doing so, we define the family of Hilbert α divergences and show how it relates with other divergences used in quantum information theory. We then apply these tools to the problem of deciding the existence of a suitable transformation from an initial pair of quantum states to a final one, focusing in particular on applications to the resource theory of athermality, a precursor of quantum thermodynamics.

  17. Multipulse phase resetting curves

    NASA Astrophysics Data System (ADS)

    Krishnan, Giri P.; Bazhenov, Maxim; Pikovsky, Arkady

    2013-10-01

    In this paper, we introduce and study systematically, in terms of phase response curves, the effect of dual-pulse excitation on the dynamics of an autonomous oscillator. Specifically, we test the deviations from linear summation of phase advances resulting from two small perturbations. We analytically derive a correction term, which generally appears for oscillators whose intrinsic dimensionality is >1. The nonlinear correction term is found to be proportional to the square of the perturbation. We demonstrate this effect in the Stuart-Landau model and in various higher dimensional neuronal models. This deviation from the superposition principle needs to be taken into account in studies of networks of pulse-coupled oscillators. Further, this deviation could be used in the verification of oscillator models via a dual-pulse excitation.

  18. Automated reasoning about cubic curves.

    SciTech Connect

    Padmanabhan, R.; McCune, W.; Mathematics and Computer Science; Univ. of Manitoba

    1995-01-01

    It is well known that the n-ary morphisms defined on projective algebraic curves satisfy some strong local-to-global equational rules of derivation not satisfied in general by universal algebras. For example, every rationally defined group law on a cubic curve must be commutative. Here we extract from the geometry of curves a first order property (gL) satisfied by all morphisms defined on these curves such that the equational consequences known for projective curves can be derived automatically from a set of six rules (stated within the first-order logic with equality). First, the rule (gL) is implemented in the theorem-proving program Otter. Then we use Otter to automatically prove some incidence theorems on projective curves without any further reference to the underlying geometry or topology of the curves.

  19. Combined electrophoretic-separation and electrospray method and system

    DOEpatents

    Smith, R.D.; Olivares, J.A.

    1989-06-27

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary zone electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., [+-]2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit. 10 figs.

  20. Electrohydrodynamic simulation of an electrospray in a colloid thruster

    NASA Astrophysics Data System (ADS)

    Jugroot, Manish; Forget, Martin; Malardier-Jugroot, Cecile

    2012-02-01

    A precise understanding of electrosprays is highly interesting as the complexity of micro-technology (such as nano-material processing, spacecraft propulsion and mass-spectrometers) systems increases. A multi-component CFD-based model coupling fluid dynamics, charged species dynamics and electric field is developed. The simulations describe the charged fluid interface with emphasis on the Taylor cone formation and cone-jet transition under the effect of a electric field. The goal is to recapture this transition from a rounded liquid interface into a Taylor cone from an initial uniform distribution, without making assumptions on the behaviour, geometry or charge distribution of the system. The time evolution of the interface highlights the close interaction among space charge, coulombic forces and the surface tension, which appear as governing and competing processes in the transition. The results from the coupled formalism provide valuable insights on the physical phenomena and will be applied to a colloid thruster for small spacecrafts.

  1. pH Effects on Electrospray Ionization Efficiency

    NASA Astrophysics Data System (ADS)

    Liigand, Jaanus; Laaniste, Asko; Kruve, Anneli

    2017-03-01

    Electrospray ionization efficiency is known to be affected by mobile phase composition. In this paper, a detailed study of analyte ionization efficiency dependence on mobile phase pH is presented. The pH effect was studied on 28 compounds with different chemical properties. Neither p K a nor solution phase ionization degree by itself was observed to be sufficient at describing how aqueous phase pH affects the ionization efficiency of the analyte. Therefore, the analyte behavior was related to various physicochemical properties via linear discriminant analyses. Distinction between pH-dependent and pH-independent compounds was achieved using two parameters: number of potential charge centers and hydrogen bonding acceptor capacity (in the case of 80% acetonitrile) or polarity of neutral form of analyte and p K a (in the case of 20% acetonitrile). It was also observed that decreasing pH may increase ionization efficiency of a compound by more than two orders of magnitude.

  2. Planar flow-by electrode capacitive electrospray ion source

    DOEpatents

    Van Berkel, Gary J.

    2004-01-13

    An electrospray ion source includes a chamber including a channel region therein, the channel including at least one inlet for directing a solution into the channel and at least a first and a second outlet for transmitting the solution or derivatives therefrom out from channel. Structure for separating ions in the solution is provided from separating the solution into at least a first and a second flow stream portion. The first flow stream portion is enriched in negative ions and the second flow stream portion is enriched in positive ions. The first flow stream portion is adapted to exit the chamber through the first outlet while the second flow stream portion is adapted to exit the chamber through the second outlet. A method of charge separation can include the step of simultaneously providing at least two gas phase ion stream portions having opposite polarity.

  3. Improved Imaging Resolution in Desorption Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Kertesz, Vilmos; Van Berkel, Gary J

    2008-01-01

    Imaging resolution of desorption electrospray ionization mass spectrometry (DESI-MS) was investigated using printed patterns on paper and thin-layer chromatography (TLC) plate surfaces. Resolution approaching 40 m was achieved with a typical DESI-MS setup, which is approximately 5 times better than the best resolution reported previously. This improvement was accomplished with careful control of operational parameters (particularly spray tip-to-surface distance, solvent flow rate, and spacing of lane scans). Also, an appropriately strong analyte/surface interaction and uniform surface texture on the size scale no larger that the desired imaging resolution were required to achieve this resolution. Overall, conditions providing the smallest possible effective desorption/ionization area in the DESI impact plume region and minimizing the analyte redistribution on the surface during analysis led to the improved DESI-MS imaging resolution.

  4. Influence of boric acid on electrospray ionization efficiency.

    PubMed

    Rebane, Riin; Herodes, Koit

    2012-01-01

    Liquid chromatography electrospray ionization mass-spectrometry (LC-ESI-MS) was used to analyze 9-fluorenylmethylmethoxycarbonyl chloride (Fmoc-Cl) and diethyl ethoxymethylenemalonate (Deemm) derivatives of three amino acids and five other compounds. Influence of boric acid on their ionization was investigated and dramatic impact on the signal was observed. The strongest signal suppression (6% of signal remains) was observed for the Deemm derivative of beta-Alanine (with ammonium acetate in eluent). With only formic acid as the eluent pH modifier, signal enhancement was observed, being largest for Fmoc-Cl derivative of Phenylalanine, 267%. Investigation of the influence of boric acid shows that it is a possible signal enhancer for LC-ESI-MS analysis.

  5. Collisional cooling of large ions in electrospray mass spectrometry.

    PubMed

    Chernushevich, Igor V; Thomson, Bruce A

    2004-03-15

    Collisional cooling of ions in the rf-only multipole guides has become a method of choice for coupling electrospray sources to various mass analyzers. Normally parameters of such ion guides (length, pressure) provide enough thermalization and focusing for ions in a wide mass range. Noncovalent complexes, however, have more compact conformations than denatured biomolecules of similar mass and, therefore may not be transmitted efficiently through standard ion guides, as demonstrated by theoretical analysis, simulations, and experiments. Several methods of improving collisional cooling for large compact ions have been developed on a quadrupole time-of-flight instrument, which include operating the ion guides at higher pressure and trapping ions to increase the cooling time. Improved transmission of heavy ions obtained with those methods is studied in experiments with proteasome 20S, an oligomeric protein noncovalent complex with molecular weight around 692,000, and a few other compounds.

  6. Combined electrophoretic-separation and electrospray method and system

    DOEpatents

    Smith, Richard D.; Olivares, Jose A.

    1989-01-01

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary zone electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit.

  7. Coupling Electrochemistry with Probe Electrospray Ionization Mass Spectrometry.

    PubMed

    Cai, Yi; Liu, Pengyuan; Held, Michael A; Dewald, Howard D; Chen, Hao

    2016-04-18

    A new coupling of electrochemistry with mass spectrometry (MS) using probe electrospray ionization (PESI) is presented. Due to the high salt tolerance of PESI, the detection of electrochemical reaction products in room-temperature ionic liquids (RTILs) is realized for the first time. Furthermore, PESI-MS allows the analysis of electrochemical reaction products on different or multiple electrode surfaces. In addition, peptides and proteins fractionated through isoelectric focusing (IEF) in the presence of an external electric field can also be directly analyzed by using PESI-MS, suggesting a new and rapid characterization means for the IEF technique. This study reveals the versatility of EC/PESI-MS, which could have an impact in electrochemistry and bioanalysis fields.

  8. Application of spray-drying and electrospraying/electospinning for poorly water-soluble drugs: a particle engineering approach.

    PubMed

    Bohr, Adam; Boetker, Johan P; Rades, Thomas; Rantanen, Jukka; Yang, Mingshi

    2014-01-01

    Solid dispersions have been widely studied as an attractive formulation strategy for the increasingly prevalent poorly water-soluble drug compounds, including herbal medicines, often leading to improvements in drug dissolution rate and bioavailability. However, several challenges are encountered with solid dispersions, for instance regarding their physical stability, and the full potential of these formulations has yet to be reached. Solid dispersions have mainly been used to produce immediate release systems using water-soluble polymers but an extended release system may provide equal or better performance due to enhancement in the pharmacokinetics and low variability in plasma concentration. Progress in processing technologies and particle engineering provides new opportunities to prepare particle-based solid dispersions with control of physical characteristics and tailored drug release kinetics. Spray-drying and electrospraying are both technologies that allow production and continuous manufacturing of particle-based amorphous solid dispersions in a single step process and electrospinning further allows the production of fiber based systems. This review presents the use of spray drying and electrospraying/electrospinning as techniques for preparing particle-based solid dispersions, describes the particle formation processes via numerical and experimental models and discusses particle engineering using these techniques. Examples are given on the applications of these techniques for preparing solid dispersions and the challenges associated with the techniques such as stability, preparation of final dosage form and scale-up are also discussed.

  9. A novel method for bacterial inactivation using electrosprayed water nanostructures

    NASA Astrophysics Data System (ADS)

    Pyrgiotakis, Georgios; McDevitt, James; Yamauchi, Toshiyuki; Demokritou, Philip

    2012-08-01

    This is a study focusing on the potential to deactivate biological agents (bacteria and endospores) using engineered water nanostructures (EWNS). The EWNS were generated using an electrospray device that collects water by condensing atmospheric water vapor on a Peltier-cooled electrode. A high voltage is applied between the collection electrode and a grounded electrode resulting in aerosolization of the condensed water and a constant generation of EWNS. Gram-negative Serratia marcescens, gram-positive Staphylococcus aureus, and Bacillus atrophaeus endospores were placed on stainless steel coupons and exposed to generated EWNS at multiple time intervals. Upon exposures, the bacteria were recovered and placed on nutrient agar to grow, and the colony forming units were counted. Ozone levels as well as air temperature and relative humidity were monitored during the experiments. Qualitative confirmation of bacterial destruction was also obtained by transmission electron microscopy. In addition, important EWNS aerosol properties such as particle number concentration as a function of size as well as the average surface charge of the generated EWNS were measured using real-time instrumentation. It was shown that the novel electrospray method can generate over time a constant flux of EWNS. EWNS have a peak number concentration of 8,000 particles per cubic centimeter with a modal peak size around 20 nm. The average surface charge of the generated EWNS was found to be 10 ± 2 electrons per particle. In addition, it was shown that the EWNS have the potential to deactivate both bacteria types from surfaces. At the same administrate dose, however, the endospores were not inactivated. This novel method and the unique properties of the generated EWNS could potentially be used to develop an effective, environmentally friendly, and inexpensive method for bacteria inactivation.

  10. Electrospray neutralization process and apparatus for generation of nano-aerosol and nano-structured materials

    SciTech Connect

    Bailey, Charles L.; Morozov, Victor; Vsevolodov, Nikolai N.

    2010-08-17

    The claimed invention describes methods and apparatuses for manufacturing nano-aerosols and nano-structured materials based on the neutralization of charged electrosprayed products with oppositely charged electrosprayed products. Electrosprayed products include molecular ions, nano-clusters and nano-fibers. Nano-aerosols can be generated when neutralization occurs in the gas phase. Neutralization of electrospan nano-fibers with molecular ions and charged nano-clusters may result in the formation of fibrous aerosols or free nano-mats. Nano-mats can also be produced on a suitable substrate, forming efficient nano-filters.

  11. Water-assisted femtosecond laser machining of electrospray nozzles on glass microfluidic devices.

    PubMed

    An, Ran; Hoffman, Michelle D; Donoghue, Margaret A; Hunt, Alan J; Jacobson, Stephen C

    2008-09-15

    Using water-assisted femtosecond laser machining, we fabricated electrospray nozzles on glass coverslips and on assembled microfluidic devices. Machining the nozzles after device assembly facilitated alignment of the nozzles over the microchannels. The basic nozzle design is a through-hole in the coverslip to pass liquids and a trough machined around the through-hole to confine the electrospray and prevent liquid from wicking across the glass surface. Electrospray from the nozzles was stable with and without pressure-driven flow applied and was evaluated using mass spectra of the peptide bradykinin.

  12. On-line capillary isoelectric focusing-electrospray mass spectrometry for protein characterization

    SciTech Connect

    Tang, Qing; Harrata, K.A.; Lee, C.S.

    1996-12-31

    The integration of capillary isoelectric focusing (CIEF) with electrospray mass spectrometry (ESMS) as a two-dimensional separation system for protein characterization will be presented. Mixtures of protein variants are focused and cathodically mobilized in a polyacrylamide coated capillary. At the end of CIEF capillary, the mobilized protein zones are analyzed by mass spectrometry coupled on-line to an electrospray interface with a coaxial sheath flow configuration. The effects of carrier ampholyte concentration on the CIEF separation and the protein electrospray mass spectra will be discussed. On-line CIEF-ESMS with superior resolving power, speed, and sensitivity will be demonstrated for the analysis of hemoglobin and glycoprotein variants.

  13. Birational maps that send biquadratic curves to biquadratic curves

    NASA Astrophysics Data System (ADS)

    Roberts, John A. G.; Jogia, Danesh

    2015-02-01

    Recently, many papers have begun to consider so-called non-Quispel-Roberts-Thompson (QRT) birational maps of the plane. Compared to the QRT family of maps which preserve each biquadratic curve in a fibration of the plane, non-QRT maps send a biquadratic curve to another biquadratic curve belonging to the same fibration or to a biquadratic curve from a different fibration of the plane. In this communication, we give the general form of a birational map derived from a difference equation that sends a biquadratic curve to another. The necessary and sufficient condition for such a map to exist is that the discriminants of the two biquadratic curves are the same (and hence so are the j-invariants). The result allows existing examples in the literature to be better understood and allows some statements to be made concerning their generality.

  14. Effect of Fuselage and Tail Surfaces on Low-speed Yawing Characteristics of a Swept-wing Model as Determined in Curved-flow Test Section of Langley Stability Tunnel

    NASA Technical Reports Server (NTRS)

    Bird, John D; Jaquet, Byron M; Cowan, John W

    1951-01-01

    Results are presented of a wind-tunnel investigation made to determine the influence of the fuselage and tail surfaces on the rotary derivatives in yawing flight of a transonic-airplane configuration having 45 degrees sweptback wing and tail surfaces. The tests were run in the curved-flow test section of the Langley stability tunnel at a Reynolds number of 1.07 X 10 to the sixth power and consisted of balance measurements throughout the angle-of-attack range for several flight-path radii of curvature. The results are compared with data from forced-oscillation and free-oscillation tests, and a description of testing techniques used is included.

  15. A proposal of the diagnosis-dynamic characteristic (DDC) model describing the relation between search time and confidence levels for a dichotomous judgment, and its application to ROC curve generation

    NASA Astrophysics Data System (ADS)

    Matsumoto, Toru; Fukuda, Nobuo; Furukawa, Akira; Suwa, Koji; Wada, Shinichi; Matsumoto, Mitsuomi; Sone, Shusuke

    2006-03-01

    When physicians inspect an image, they make up a certain degree of confidence that the image are abnormal; p(t), or normal; n(t)[n(t)=1-p(t)]. After infinite time of the inspection, they reach the equilibrium levels of the confidence of p*=p(∞) and n*=n(∞). There are psychological conflicts between the decisions of normal and abnormal. We assume that the decision of "normal" is distracted by the decision of "abnormal" by a factor of k(1 + ap), and in an inverse direction by a factor of k(1 + bn), where k ( > 0) is a parameter that relates with image quality and skill of the physicians, and a and b are unknown constants. After the infinite time of inspection, the conflict reaches the equilibrium, which satisfies the equation, k(1 + ap*)n* = k(1 + bn*)p*. Here we define a parameter C, which is 2p*/[p*(1 - p*)]. After the infinite time of inspection, the conflict reaches the equilibrium, which satisfies t that changes in the confidence level with the time (dp/dt) is proportional to [k(1+ap)n - k(1+bn)p], i.e. k[-cp2 + (c - 2)p + 1]. Solving the differential equation, we derived the equation; t(p) and p(t) depending with the parameters; k, c, S. S (0-1) is the value arbitrary selected and related with probability of "abnormal" before the image inspection (S = p(0)). Image reading studies were executed for CT images. ROC curves were generated both by the traditional 4-step score-based method and by the confidence level; p estimated from the equation t(p) of the DDC model using observed judgment time. It was concluded that ROC curves could be generated by measuring time for dichotomous judgment without the subjective scores of diagnostic confidence and applying the DDC model.

  16. Differentiating microbial forensic qPCR target and control products by electrospray ionization mass spectrometry.

    PubMed

    Motley, S Timothy; Redden, Cassie L; Sannes-Lowery, Kristin A; Eshoo, Mark W; Hofstadler, Steven A; Burans, James P; Rosovitz, M J

    2013-06-01

    Molecular bioforensic research is dependent on rapid and sensitive methods such as real-time PCR (qPCR) for the identification of microorganisms. The use of synthetic positive control templates containing small modifications outside the primer and probe regions is essential to ensure all aspects of the assay are functioning properly, including the primers and probes. However, a typical qPCR or reverse transcriptase qPCR (qRT-PCR) assay is limited in differentiating products generated from positive controls and biological samples because the fluorescent probe signals generated from each type of amplicon are indistinguishable. Additional methods used to differentiate amplicons, including melt curves, secondary probes, and amplicon sequencing, require significant time to implement and validate and present technical challenges that limit their use for microbial forensic applications. To solve this problem, we have developed a novel application of electrospray ionization mass spectrometry (ESI-MS) to rapidly differentiate qPCR amplicons generated with positive biological samples from those generated with synthetic positive controls. The method has sensitivity equivalent to qPCR and supports the confident and timely determination of the presence of a biothreat agent that is crucial for policymakers and law enforcement. Additionally, it eliminates the need for time-consuming methods to confirm qPCR results, including development and validation of secondary probes or sequencing of small amplicons. In this study, we demonstrate the effectiveness of this approach with microbial forensic qPCR assays targeting multiple biodefense agents (bacterial, viral, and toxin) for the ability to rapidly discriminate between a positive control and a positive sample.

  17. Technical note: Air compared to nitrogen as nebulizing and drying gases for electrospray ionization mass spectrometry.

    PubMed

    Mielczarek, P; Silberring, J; Smoluch, M

    2016-01-01

    In the present study we tested the application of compressed air instead of pure nitrogen as the nebulizing and drying gas, and its influence on the quality of electrospray ionization (ESI) mass spectra. The intensities of the signals corresponding to protonated molecules were significantly (twice) higher when air was used. Inspection of signal-to-noise (S/N) ratios revealed that, in both cases, sensitivity was comparable. A higher ion abundance after the application of compressed air was followed by a higher background. Another potential risk of using air in the ESI source is the possibility for sample oxidation due to the presence of oxygen. To test this, we selected five easily oxidizing compounds to verify their susceptibility to oxidation. In particular, the presence of methionine was of interest. For all the compounds studied, no oxidation was observed. Amodiaquine oxidizes spontaneously in water solutions and its oxidized form can be detected a few hours after preparation. Direct comparison of the spectra where nitrogen was used with the corresponding spectra obtained when air was applied did not show significant differences. The only distinction was slightly different patterns of adducts when air was used. The difference concerns acetonitrile, which forms higher signals when air is the nebulizing gas. It is also important that the replacement of nitrogen with air does not affect quantitative data. The prepared calibration curves also visualize an intensity twice as high (independent of concentration within tested range) of the signal where air was applied. We have used our system continuously for three months with air as the nebulizing and drying gas and have not noticed any unexpected signal deterioration caused by additional source contamination from the air. Moreover, compressed air is much cheaper and easily available using oil-free compressors or pumps.

  18. Quantitative Detection of Trace Malachite Green in Aquiculture Water Samples by Extractive Electrospray Ionization Mass Spectrometry

    PubMed Central

    Fang, Xiaowei; Yang, Shuiping; Chingin, Konstantin; Zhu, Liang; Zhang, Xinglei; Zhou, Zhiquan; Zhao, Zhanfeng

    2016-01-01

    Exposure to malachite green (MG) may pose great health risks to humans; thus, it is of prime importance to develop fast and robust methods to quantitatively screen the presence of malachite green in water. Herein the application of extractive electrospray ionization mass spectrometry (EESI-MS) has been extended to the trace detection of MG within lake water and aquiculture water, due to the intensive use of MG as a biocide in fisheries. This method has the advantage of obviating offline liquid-liquid extraction or tedious matrix separation prior to the measurement of malachite green in native aqueous medium. The experimental results indicate that the extrapolated detection limit for MG was ~3.8 μg·L−1 (S/N = 3) in lake water samples and ~0.5 μg·L−1 in ultrapure water under optimized experimental conditions. The signal intensity of MG showed good linearity over the concentration range of 10–1000 μg·L−1. Measurement of practical water samples fortified with MG at 0.01, 0.1 and 1.0 mg·L−1 gave a good validation of the established calibration curve. The average recoveries and relative standard deviation (RSD) of malachite green in lake water and Carassius carassius fish farm effluent water were 115% (6.64% RSD), 85.4% (9.17% RSD) and 96.0% (7.44% RSD), respectively. Overall, the established EESI-MS/MS method has been demonstrated suitable for sensitive and rapid (<2 min per sample) quantitative detection of malachite green in various aqueous media, indicating its potential for online real-time monitoring of real life samples. PMID:27529262

  19. Quantitative Detection of Trace Malachite Green in Aquiculture Water Samples by Extractive Electrospray Ionization Mass Spectrometry.

    PubMed

    Fang, Xiaowei; Yang, Shuiping; Chingin, Konstantin; Zhu, Liang; Zhang, Xinglei; Zhou, Zhiquan; Zhao, Zhanfeng

    2016-08-11

    Exposure to malachite green (MG) may pose great health risks to humans; thus, it is of prime importance to develop fast and robust methods to quantitatively screen the presence of malachite green in water. Herein the application of extractive electrospray ionization mass spectrometry (EESI-MS) has been extended to the trace detection of MG within lake water and aquiculture water, due to the intensive use of MG as a biocide in fisheries. This method has the advantage of obviating offline liquid-liquid extraction or tedious matrix separation prior to the measurement of malachite green in native aqueous medium. The experimental results indicate that the extrapolated detection limit for MG was ~3.8 μg·L(-1) (S/N = 3) in lake water samples and ~0.5 μg·L(-1) in ultrapure water under optimized experimental conditions. The signal intensity of MG showed good linearity over the concentration range of 10-1000 μg·L(-1). Measurement of practical water samples fortified with MG at 0.01, 0.1 and 1.0 mg·L(-1) gave a good validation of the established calibration curve. The average recoveries and relative standard deviation (RSD) of malachite green in lake water and Carassius carassius fish farm effluent water were 115% (6.64% RSD), 85.4% (9.17% RSD) and 96.0% (7.44% RSD), respectively. Overall, the established EESI-MS/MS method has been demonstrated suitable for sensitive and rapid (<2 min per sample) quantitative detection of malachite green in various aqueous media, indicating its potential for online real-time monitoring of real life samples.

  20. Differentiating Microbial Forensic qPCR Target and Control Products by Electrospray Ionization Mass Spectrometry

    PubMed Central

    Motley, S. Timothy; Redden, Cassie L.; Sannes-Lowery, Kristin A.; Eshoo, Mark W.; Hofstadler, Steven A.; Burans, James P.

    2013-01-01

    Molecular bioforensic research is dependent on rapid and sensitive methods such as real-time PCR (qPCR) for the identification of microorganisms. The use of synthetic positive control templates containing small modifications outside the primer and probe regions is essential to ensure all aspects of the assay are functioning properly, including the primers and probes. However, a typical qPCR or reverse transcriptase qPCR (qRT-PCR) assay is limited in differentiating products generated from positive controls and biological samples because the fluorescent probe signals generated from each type of amplicon are indistinguishable. Additional methods used to differentiate amplicons, including melt curves, secondary probes, and amplicon sequencing, require significant time to implement and validate and present technical challenges that limit their use for microbial forensic applications. To solve this problem, we have developed a novel application of electrospray ionization mass spectrometry (ESI-MS) to rapidly differentiate qPCR amplicons generated with positive biological samples from those generated with synthetic positive controls. The method has sensitivity equivalent to qPCR and supports the confident and timely determination of the presence of a biothreat agent that is crucial for policymakers and law enforcement. Additionally, it eliminates the need for time-consuming methods to confirm qPCR results, including development and validation of secondary probes or sequencing of small amplicons. In this study, we demonstrate the effectiveness of this approach with microbial forensic qPCR assays targeting multiple biodefense agents (bacterial, viral, and toxin) for the ability to rapidly discriminate between a positive control and a positive sample. PMID:23675878

  1. Langevin Equation on Fractal Curves

    NASA Astrophysics Data System (ADS)

    Satin, Seema; Gangal, A. D.

    2016-07-01

    We analyze random motion of a particle on a fractal curve, using Langevin approach. This involves defining a new velocity in terms of mass of the fractal curve, as defined in recent work. The geometry of the fractal curve, plays an important role in this analysis. A Langevin equation with a particular model of noise is proposed and solved using techniques of the Fα-Calculus.

  2. Reflection of curved shock waves

    NASA Astrophysics Data System (ADS)

    Mölder, S.

    2017-03-01

    Shock curvatures are related to pressure gradients, streamline curvatures and vorticity in flows with planar and axial symmetry. Explicit expressions, in an influence coefficient format, are used to relate post-shock pressure gradient, streamline curvature and vorticity to pre-shock gradients and shock curvature in steady flow. Using higher order, von Neumann-type, compatibility conditions, curved shock theory is applied to calculate the flow near singly and doubly curved shocks on curved surfaces, in regular shock reflection and in Mach reflection. Theoretical curved shock shapes are in good agreement with computational fluid dynamics calculations and experiment.

  3. Shape Preserving Interpolation by Curves

    DTIC Science & Technology

    2001-07-01

    curves Given data 1i E R2 , i = 0,..., N, we consider a curve r : [a, b] -- R2 satisfying r(ti) = Ii , i = 0,..., N, (3.1) for values a = to < tj...tN = b. For a closed curve the situation is extended periodically so that Ii +N =10, ti+N =ti, i E Z, r(t+b-a) =r(t), tc R. 3.1 Desirable properties...para- meterisation). When all vi = 0, r will reduce to the usual C2 cubic spline interpolant. As vi --+ oc, the curve is ’pulled tight’ at Ii and as

  4. The updated bottom up solution applied to atmospheric pressure photoionization and electrospray ionization mass spectrometry

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The Updated Bottom Up Solution (UBUS) was recently applied to atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) of triacylglycerols (TAGs). This report demonstrates that the UBUS applies equally well to atmospheric pressure photoionization (APPI) MS and to electrospray ionizatio...

  5. Preparation of inorganic/organic polymer hybrid microcapsules with high encapsulation efficiency by an electrospray technique.

    PubMed

    Yunoki, Ayumi; Tsuchiya, Eiko; Fukui, Yu; Fujii, Akihiro; Maruyama, Tatsuo

    2014-08-13

    Microcapsules composed of calcium phosphate and chitosan were prepared in a single step by electrospraying. An aqueous solution containing calcium chloride and chitosan was electrosprayed into a phosphate solution to form a calcium phosphate shell on the sprayed droplets. The resulting microcapsules were 350 μm in average diameter. Investigation using fluorescently labeled chitosan and XRD measurements revealed that the shells of the microcapsules were composed of calcium phosphate (mainly hydroxyapatite) and chitosan. Instead of chitosan, poly(diallyldimethylammonium chloride) and polyethylene glycol were also available for microcapsule production by electrospraying. Variations in the electrospraying conditions resulted in a variety of microcapsule shapes. Various types of substrates were successfully encapsulated in microcapsules with a high encapsulation efficiency (more than 80%). Finally, we succeeded in the encapsulation of living yeast cells in microcapsules, and observed their growth within these microcapsules.

  6. DEVELOPMENT OF AN ELECTROSPRAY MASS SPECTROMETRIC METHOD FOR DETERMINING PERCHLORATE IN FERTILIZERS

    EPA Science Inventory

    An electrospray mass spectrometric method has been developed for application to agricultural and horticultural fertilizers to determine perchlorate. After fertilizers are leached or dissolved in water, the method relies on the formation of stable ion pair complex of the perchlor...

  7. Poly(amidoamine)-Cholesterol Conjugate Nanoparticles Obtained by Electrospraying as Novel Tamoxifen Delivery System

    PubMed Central

    Cavalli, R.; Bisazza, A.; Bussano, R.; Trotta, M.; Civra, A.; Lembo, D.; Ranucci, E.; Ferruti, P.

    2011-01-01

    A new poly(amidoamine)-cholesterol (PAA-cholesterol) conjugate was synthesized, characterized and used to produce nanoparticles by the electrospraying technique. The electrospraying is a method of liquid atomization that consists in the dispersion of a solution into small charged droplets by an electric field. Tuning the electrospraying process parameters spherical PAA-chol nanoparticles formed. The PAA-cholesterol nanoparticles showed sizes lower than 500 nm and spherical shape. The drug incorporation capacity was investigated using tamoxifen, a lipophilic anticancer drug, as model drug. The incorporation of the tamoxifen did not affect the shape and sizes of nanoparticles showing a drug loading of 40%. Tamoxifen-loaded nanoparticles exhibited a higher dose-dependent cytotoxicity than free tamoxifen, while blank nanoparticles did not show any cytotoxic effect at the same concentrations. The electrospray technique might be proposed to produce tamoxifen-loaded PAA-chol nanoparticle in powder form without any excipient in a single step. PMID:21785731

  8. Simultaneous determination of trace oxyhalides and haloacetic acids using suppressed ion chromatography-electrospray mass spectrometry.

    PubMed

    Barron, Leon; Paull, Brett

    2006-05-15

    A new analytical procedure for the simultaneous determination of trace oxyhalides and haloacetic acids (HAs) in drinking water and aqueous soil extracts is described. The method uses micro-bore ion chromatography (IC) coupled with suppressed conductivity (SC) and electrospray ionization mass spectrometric detection (ESI-MS). The IC-SC-ESI-MS system included a secondary flow of 100% MeOH, which was added to the column eluate (post-suppressor) and resulted in a significant increase in sensitivity for all analytes. All ESI-MS parameters were optimized for HA analysis and sensitivity quantitatively compared to suppressed conductivity. Full analytical performance characteristics for the developed method are presented for monochloro-, monobromo-, dichloro-, dibromo-, trichloro-, bromochloro, chlorodifluoro-, trifluoro-, dichlorobromo- and dibromochloroacetic acid, as well as the oxyhalides iodate, bromate, chlorate and perchlorate. In the case of the HAs, an optimised 25-fold SPE preconcentration method meant all analytes could be readily detected well below the USEPA 60mug/L regulatory limit using conductivity and/or ESI-MS. The IC-ESI-MS method was applied to the determination of oxyhalides and HAs in both soil extracts and drinking water samples. Soil samples were extracted using ultra pure water with subsequent determination of perchlorate at 1.68mug/g of soil. A drinking water sample containing HAs was preconcentrated using LiChrolut EN solid phase extraction cartridges with subsequent sulphate and chloride removal. Total HAs were determined at 13mug/L.

  9. Complexation of malic acid with cadmium(II) probed by electrospray ionization mass spectrometry.

    PubMed

    Jaklová Dytrtová, Jana; Jakl, Michal; Schröder, Detlef

    2012-02-15

    Electrospray ionization was used as a technique for the characterization of the interactions between cadmium(II) ions and malic acid (1) in aqueous solution. Particular attention was paid to the nature of the species formed, which generally correspond to complexes of CdX(+) cations with neutral malic acid, where X either is the counterion of the metal salt used as a precursor (i.e. X=Cl, I) or corresponds to singly deprotonated malic acid. In pure water solutions, also highly coordinated complexes [Cd(1-H)(1)(2)](+) and [CdCl(1)(2)](+) were detected, whereas the most abundant complexes detected in a sample of soil solution were: [Cd(1-H)(1)](+) and [CdCl(1)](+). With respect to possible application in environmental analysis, the effects of (i) metal salts present in solution, (ii) modest mineralization, and (iii) the matrices of real soil solutions were probed. While the presence of other metals leads to additional complexes, the characteristic species containing both cadmium(II) and malic acid can still be detected with good sensitivity.

  10. Characterization of N,N-dimethyl amino acids by electrospray ionization-tandem mass spectrometry.

    PubMed

    Naresh Chary, V; Sudarshana Reddy, B; Kumar, Ch Dinesh; Srinivas, R; Prabhakar, S

    2015-05-01

    Methylation is an essential metabolic process for a number of critical reactions in the body. Methyl groups are involved in the healthy function of the body life processes, by conducting methylation process involving specific enzymes. In these processes, various amino acids are methylated, and the occurrence of methylated amino acids in nature is diverse. Nowadays, mass-spectrometric-based identification of small molecules as biomarkers for diseases is a growing research. Although all dimethyl amino acids are metabolically important molecules, mass spectral data are available only for a few of them in the literature. In this study, we report synthesis and characterization of all dimethyl amino acids, by electrospray ionization-tandem mass spectrometry (MS/MS) experiments on protonated molecules. The MS/MS spectra of all the studied dimethyl amino acids showed preliminary loss of H2O + CO to form corresponding immonium ions. The other product ions in the spectra are highly characteristic of the methyl groups on the nitrogen and side chain of the amino acids. The amino acids, which are isomeric and isobaric with the studied dimethyl amino acids, gave distinctive MS/MS spectra. The study also included MS/MS analysis of immonium ions of dimethyl amino acids that provide information on side chain structure, and it is further tested to determine the N-terminal amino acid of the peptides.

  11. Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Wahl, Karen L.; Colburn, Heather A.; Wunschel, David S.; Petersen, Catherine E.; Jarman, Kristin H.; Valentine, Nancy B.

    2010-02-15

    Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and not in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.

  12. Online coupling of electrochemical reactions with liquid sample desorption electrospray ionization-mass spectrometry.

    PubMed

    Li, Jiwen; Dewald, Howard D; Chen, Hao

    2009-12-01

    The combination of electrochemistry (EC) and mass spectrometry (MS) is a powerful analytical tool to study redox reactions. This work reports the online coupling of a thin-layer electrochemical flow cell with liquid sample desorption electrospray ionization mass spectrometry (DESI-MS) and its applications in investigating various electrochemical reactions of biological molecules such as oxidative formation and reductive cleavage of disulfide bonds and online derivatization of peptides/proteins. As a result of the direct sampling nature of DESI, several useful features of such a coupling have been found, including simple instrumentation, fast response time (e.g., 3.6 s in the case of dopamine oxidation), freedom to choose a favorable ionization mode of DESI or traditional electrolysis solvent systems, and the absence of background signal possibly resulting from ionization when the cell is off (e.g., in the case of dopamine oxidation). More importantly, with the use of this new coupling apparatus, three disulfide bonds of insulin were fully cleaved by electrolytic reduction and both the A and B chains of the protein were successfully detected online by DESI-MS. In addition, online tagging of free cysteine residues of peptides/proteins employing electrogenerated dopamine o-quinone can be performed. These revealed characteristics of the coupling along with examined electrochemical reactions suggest that EC/DESI-MS has good potential in bioanalysis.

  13. The wavelength dependence of Triton's light curve

    NASA Technical Reports Server (NTRS)

    Hillier, J.; Veverka, J.; Helfenstein, P.; Mcewen, A.

    1991-01-01

    Using Voyager observations, it is demonstrated that Triton's orbital light curve is strongly wavelength-dependent, a characteristic which readily explains some of the apparent discrepancies among pre-Voyager telescopic measurements. Specifically, a light curve amplitude (peak to peak) is found that decreases systematically with increasing wavelength from about 0.08 magnitude (peak to peak) near 200 nm to less than 0.02 magnitude near 1000 nm. Peak brightness occurs near 90 deg orbital longitude (leading hemisphere). The brightness variation across this hemisphere is close to sinusoidal; the variation across the darker hemisphere is more complex. The decrease in light curve amplitude with increasing wavelength appears to be due to a decrease in contrast among surface markings, rather than to atmospheric obscuration. The model also explains the observed decrease in the amplitude of Triton's light curve at visible wavelengths over the past decade, a decrease related to the current migration of the subsolar latitude toward the south pole; it is predicted that this trend will continue into the 1990s.

  14. Light extraction block with curved surface

    DOEpatents

    Levermore, Peter; Krall, Emory; Silvernail, Jeffrey; Rajan, Kamala; Brown, Julia J.

    2016-03-22

    Light extraction blocks, and OLED lighting panels using light extraction blocks, are described, in which the light extraction blocks include various curved shapes that provide improved light extraction properties compared to parallel emissive surface, and a thinner form factor and better light extraction than a hemisphere. Lighting systems described herein may include a light source with an OLED panel. A light extraction block with a three-dimensional light emitting surface may be optically coupled to the light source. The three-dimensional light emitting surface of the block may includes a substantially curved surface, with further characteristics related to the curvature of the surface at given points. A first radius of curvature corresponding to a maximum principal curvature k.sub.1 at a point p on the substantially curved surface may be greater than a maximum height of the light extraction block. A maximum height of the light extraction block may be less than 50% of a maximum width of the light extraction block. Surfaces with cross sections made up of line segments and inflection points may also be fit to approximated curves for calculating the radius of curvature.

  15. Controlled release behaviour of protein-loaded microparticles prepared via coaxial or emulsion electrospray.

    PubMed

    Wang, Ying; Yang, Xiaoping; Liu, Wentao; Zhang, Feng; Cai, Qing; Deng, Xuliang

    2013-01-01

    Biodegradable poly (lactic-co-glycolic acid) (PLGA) microparticles are an effective way to achieve sustained drug release. In this study, we investigated a sustained release model of PLGA microparticles with incorporated protein via either emulsion or coaxial electrospray techniques. PLGA (75:25) was used as the carrier, and bovine serum albumin as a model protein. Coaxial electrospray resulted in a type of core-shell structure with mean diameters of 2.41 ± 0.60 µm and a centralised protein distribution within the core. Emulsion electrospray formed bigger microparticles with mean diameters of 22.75 ± 8.05 µm and a heterogeneous protein distribution throughout the microparticles. The coaxial electrospray microparticles presented a much slighter burst release than the emulsion electrospray microparticles. Loading efficiency was significantly higher (p < 0.05) in the coaxial group than emulsion group. This indicated that both emulsion and coaxial electrospray could produce protein-loaded microparticles with sustained release behaviour, but the former revealed a superior approach for drug delivery.

  16. Controlled release behaviour of protein-loaded microparticles prepared via coaxial or emulsion electrospray

    PubMed Central

    Wang, Ying; Yang, Xiaoping; Liu, Wentao; Zhang, Feng; Cai, Qing; Deng, Xuliang

    2013-01-01

    Biodegradable poly (lactic-co-glycolic acid) (PLGA) microparticles are an effective way to achieve sustained drug release. In this study, we investigated a sustained release model of PLGA microparticles with incorporated protein via either emulsion or coaxial electrospray techniques. PLGA (75:25) was used as the carrier, and bovine serum albumin as a model protein. Coaxial electrospray resulted in a type of core–shell structure with mean diameters of 2.41 ± 0.60 µm and a centralised protein distribution within the core. Emulsion electrospray formed bigger microparticles with mean diameters of 22.75 ± 8.05 µm and a heterogeneous protein distribution throughout the microparticles. The coaxial electrospray microparticles presented a much slighter burst release than the emulsion electrospray microparticles. Loading efficiency was significantly higher (p < 0.05) in the coaxial group than emulsion group. This indicated that both emulsion and coaxial electrospray could produce protein-loaded microparticles with sustained release behaviour, but the former revealed a superior approach for drug delivery. PMID:23346923

  17. Analytical Characterization of the Electrospray Ion Source in the Nanoflow Regime

    SciTech Connect

    Marginean, Ioan; Kelly, Ryan T.; Prior, David C.; Lamarche, Brian L.; Tang, Keqi; Smith, Richard D.

    2008-09-01

    We provide a thorough characterization of the low-flow electrospray as an ionization source for mass spectrometry (MS) using solutions typical for reversed-phase liquid chromatography. As expected, the electrospray operating regime strongly affects the MS signal; however, contrary to conventional wisdom, the pulsating regime consistently offers better performance than the cone-jet regime in these experimental conditions. We explain this observation by a highly efficient ionization achieved by the pulsating electrospray at low flow rates, rendering the increased charge generated by a cone-jet electrospray detrimental for transmission from atmospheric pressure to vacuum through a heated capillary interface. Over a wide range of voltages, the pulsating electrospray provides a relatively constant MS signal intensity, which depends significantly on the distance between the emitter and the MS inlet. For cone-jet electrosprays the MS signal decreases slightly with increasing voltage, but the signal is less affected by the emitter-inlet distance. At flow rates up to 100 nL/min the MS signal increases with increasing flow rate due to the larger number of ions supplied into the gas phase. At flow rates greater than 100 nL/min, the signal reaches a plateau due to increasingly unsatisfactory ionization efficiency at larger flow rates.

  18. Study of superhydrophobic electrosprayed catalyst layers using a localized reference electrode technique

    NASA Astrophysics Data System (ADS)

    Chaparro, A. M.; Ferreira-Aparicio, P.; Folgado, M. A.; Brightman, E.; Hinds, G.

    2016-09-01

    The performance of electrosprayed cathode catalyst layers in a polymer electrolyte membrane fuel cell (PEMFC) is studied using a localized reference electrode technique. Single cells with an electrosprayed cathode catalyst layer show an increase of >20% in maximum power density under standard testing conditions, compared with identical cells assembled with a conventional, state-of-the-art, gas diffusion cathode. When operated at high current density (1.2 A cm-2) the electrosprayed catalyst layers show more homogeneous distribution of the localized cathode potential, with a standard deviation from inlet to outlet of <50 mV, compared with 79 mV for the conventional gas diffusion cathode. Higher performance and homogeneity of cell response is attributed to the superhydrophobic nature of the macroporous electrosprayed catalyst layer structure, which enhances the rate of expulsion of liquid water from the cathode. On the other hand, at low current densities (<0.5 A cm-2), the electrosprayed layers exhibit more heterogeneous distribution of cathode potential than the conventional cathodes; this behavior is attributed to less favorable kinetics for oxygen reduction in very hydrophobic catalyst layers. The optimum performance may be obtained with electrosprayed catalyst layers employing a high Pt/C catalyst ratio.

  19. Using the Electrochemistry of the Electrospray Ion Source

    SciTech Connect

    Van Berkel, Gary J; Kertesz, Vilmos

    2007-01-01

    Electrospray mass spectrometry (ES-MS) is one of the more widely used analysis methods in science today, impacting fields as diverse as conventional chemistry to biotechnology and materials science. , Even 20 years after bursting onto the mass spectrometry scene, the underlying processes in ES ionization continue to be better understood exposing new opportunities for the technique. , , , , Such is the case for the improved understanding related to the electrochemical processes inherent to the operation of this ion source, , , which is the topic of this report. Electrospray ionization involves three main steps prior to mass analysis: the generation and charging of the ES droplets; droplet evaporation and the production of gas-phase ions; and secondary processes that modify the gas-phase ions in the atmosphere and the sub-atmospheric pressure sampling regions of the mass spectrometer. Integral to the generation and charging of the ES droplets are electrochemical reactions that occur at the conductive contact/solution interface within or near the ES emitter to maintain the quasi-continuous production of charged droplets and ultimately gas-phase ions. The basic electrochemical phenomena concerning the ES ion source were first brought to wide attention in the mass spectrometry community by Kebarle and co-workers in the early 1990's,8 but the electrochemistry of electrostatic spray devices and possible analytical consequences resulting from this phenomenon were realized and discussed in the literature at least as far back as the mid-1970's. When asked to intercede in a debate on the significance of electrochemistry in the ES ionization (ESI) process, 2002 Nobel Laureate in Chemistry John Fenn noted that to him " the idea that electrochemical reactions might be taking place in an ES ion source was too obvious to mention. That products of such reactions are of vital significance in the overall ESI process was much less obvious. Indeed, it seems fair to say that with few

  20. Psychophysical tuning curves at very high frequencies

    NASA Astrophysics Data System (ADS)

    Yasin, Ifat; Plack, Christopher J.

    2005-10-01

    For most normal-hearing listeners, absolute thresholds increase rapidly above about 16 kHz. One hypothesis is that the high-frequency limit of the hearing-threshold curve is imposed by the transmission characteristics of the middle ear, which attenuates the sound input [Masterton et al., J. Acoust. Soc. Am. 45, 966-985 (1969)]. An alternative hypothesis is that the high-frequency limit of hearing is imposed by the tonotopicity of the cochlea [Ruggero and Temchin, Proc. Nat. Acad. Sci. U.S.A. 99, 13206-13210 (2002)]. The aim of this study was to test these hypotheses. Forward-masked psychophysical tuning curves (PTCs) were derived for signal frequencies of 12-17.5 kHz. For the highest signal frequencies, the high-frequency slopes of some PTCs were steeper than the slope of the hearing-threshold curve. The results also show that the human auditory system displays frequency selectivity for characteristic frequencies (CFs) as high as 17 kHz, above the frequency at which absolute thresholds begin to increase rapidly. The findings suggest that, for CFs up to 17 kHz, the high-frequency limitation in humans is imposed in part by the middle-ear attenuation, and not by the tonotopicity of the cochlea.

  1. Learning curves in health care.

    PubMed

    Waldman, J Deane; Yourstone, Steven A; Smith, Howard L

    2003-01-01

    This article explores the uses of learning curve theory in medicine. Though effective application of learning curve theory in health care can result in higher quality and lower cost, it is seldom methodically applied in clinical practice. Fundamental changes are necessary in the corporate culture of medicine in order to capitalize maximally on the benefits of learning.

  2. The analysis of high explosives by liquid chromatography/electrospray ionization mass spectrometry: multiplexed detection of negative ion adducts.

    PubMed

    Mathis, John A; McCord, Bruce R

    2005-01-01

    The negative ion electrospray ionization mass spectrometric (ESI-MS) detection of adducts of high explosives with chloride, formate, acetate, and nitrate was used to demonstrate the gas-phase interaction of neutral explosives with these anions. The relative intensities of the adduct species were determined to compare the competitive formation of the selected high explosives and anions. The relative stability of the adduct species varies, yielding preferential formation of certain anionic adducts with different high explosives. To exploit this effect, an isocratic high-performance liquid chromatography (HPLC)/ESI-MS method was developed and used for the simultaneous analysis of high explosives using two different techniques for the addition of the anionic additives; pre- and post-column. The results show that the pre-column approach provides similar results with improved selectivity for specific explosives. By detecting characteristic adduct species for each explosive, this method provides a qualitative and quantitative approach for the analysis and identification of high explosives.

  3. The detection of piroxicam, tenoxicam and their metabolites in equine urine by electrospray ionisation ion trap mass spectrometry.

    PubMed

    McKinney, Andrew R; Suann, Craig J; Stenhouse, Allen M

    2004-01-01

    An investigation has been conducted into the metabolism and urinary excretion of orally administered piroxicam and tenoxicam in the horse. The major component detected in urine after the administration of piroxicam was 5'-hydroxypiroxicam, which was detectable up to 24 h post-administration. Unchanged piroxicam was present only as a minor component. In contrast, unchanged tenoxicam was the major component observed after the administration of tenoxicam, being detectable for 72 h post-administration, while 5'-hydroxytenoxicam was a minor component. Phase II beta-glucuronide conjugation in each case was found to be negligible. The ion trap mass spectral characteristics of piroxicam, tenoxicam, 5'-hydroxypiroxicam and 5'-hydroxytenoxicam under electrospray ionisation conditions were examined in some detail.

  4. Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system.

    PubMed

    Ford, Michael J; Deibel, Michael A; Tomkins, Bruce A; Van Berkel, Gary J

    2005-07-15

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 mum/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 muL) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by approximately 8% or more) than the literature values.

  5. Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    SciTech Connect

    Ford, Michael J; Deibel, Michael A.; Tomkins, Bruce A; Van Berkel, Gary J

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  6. Consistency results for the ROC curves of fused classifiers

    NASA Astrophysics Data System (ADS)

    Bjerkaas, Kristopher S.; Oxley, Mark E.; Bauer, Kenneth W., Jr.

    2004-08-01

    The U.S. Air Force is researching the fusion of multiple sensors and classifiers. Given a finite collection of classifiers to be fused one seeks a new classifier with improved performance. An established performance quantifier is the Receiver Operating Characteristic (ROC) curve. This curve allows one to view the probability of detection versus probability of false alarm in one graph. In reality only finite data is available so only an approximate ROC curve can be constructed. Previous research shows that one does not have to perform an experiment for this new fused classifier to determine its ROC curve. If the ROC curve for each individual classifier has been determined, then formulas for the ROC curve of the fused classifier exist for certain fusion rules. This will be an enormous saving in time and money since the performance of many fused classifiers will be determined without having to perform tests on each one. But, again, these will be approximate ROC curves, since they are based on finite data. We show that if the individual approximate ROC curves are consistent then the approximate ROC curve for the fused classifier is also consistent under certain circumstances. We give the details for these circumstances, as well as some examples related to sensor fusion.

  7. Electrospray ionization with aluminum foil: A versatile mass spectrometric technique.

    PubMed

    Hu, Bin; So, Pui-Kin; Yao, Zhong-Ping

    2014-03-19

    In this study, we developed a novel electrospray ionization (ESI) technique based on household aluminum foil (Al foil) and demonstated the desirable features and applications of this technique. Al foil can be readily cut and folded into desired configuration for effective ionization and for holding sample solution in bulk to allowing acquisition of durable ion signals. The present technique was demonstrated to be applicable in analysis of a wide variety of samples, ranging from pure chemical and biological compounds, e.g., organic compounds and proteins, to complex samples in liquid, semi-solid, and solid states, e.g., beverages, skincare cream, and herbal medicines. The inert, hydrophobic and impermeable surface of Al foil allows convenient and effective on-target extraction of solid samples and on-target sample clean-up, i.e., removal of salts and detergents from proteins and peptides, extending ESI device from usually only for sample loading and ionization to including sample processing. Moreover, Al foil is an excellent heat-conductor and highly heat-tolerant, permitting direct monitoring of thermal reactions, e.g., thermal denaturation of proteins. Overall, the present study showed that Al-foil ESI could be an economical and versatile method that allows a wide range of applications.

  8. A New Electrospray Aerosol Generator with High Particle Transmission Efficiency

    PubMed Central

    Fu, Huijing; Patel, Anand C.; Holtzman, Michael J.; Chen, Da-Ren

    2012-01-01

    A new single-capillary electrospray (ES) aerosol generator has been developed for monodisperse particle production with maximal transmission efficiency. The new generator consists of both a spray chamber in a point-to-orifice-plate configuration and a charge reduction chamber that can hold up to 4 Nuclespot ionizers (Model P-2042, NRD Inc.). The 2 chambers are partitioned by an orifice plate. To optimize the particle transmission efficiency of the prototype, a systematic study was performed on the generator by varying the system setup and operation. Two key dimensions of the generator setup, the orifice diameter and the distance from the capillary tip to the orifice plate, were varied. Fluorescence analysis was applied to characterize the loss of ES-generated particles at different locations of the prototype. It was found that particle loss in the generator could be reduced by either increasing the orifice diameter or decreasing the distance between the capillary tip and the orifice plate. Increasing either the total radioactivity of the ionizers or the flowrate of the particle carrier gas also further decreased the particle loss in the system. The maximum particle transmission efficiency of 88.0% was obtained with the spray chamber fully opened to the charge reduction chamber, the capillary tip at the same level as the orifice plate, and 4 bipolar ionizers installed. PMID:22829715

  9. SAW Humidity Sensor Sensitivity Enhancement via Electrospraying of Silver Nanowires

    PubMed Central

    Sayar Irani, Farid; Tunaboylu, Bahadir

    2016-01-01

    In this research, we investigated the influence of the surface coatings of silver nanowires on the sensitivity of surface acoustic wave (SAW) humidity sensors. Silver nanowires, with poly(vinylpyrrolidone) (PVP), which is a hydrophilic capping agent, were chemically synthesized, with an average length of 15 µm and an average diameter of 60 nm. Humidity sensors, with 433 MHz frequency dual-port resonator Rayleigh-SAW devices, were coated by silver nanowires (AgNWs) using the electrospray coating method. It was demonstrated that increasing thickness of coated AgNW on the surfaces of SAW devices results in increased sensitivity. The highest frequency shift (262 kHz) in these SAW devices was obtained with an injection of 0.5 mL of the AgNW solution with a concentration of 0.5 mg/mL at an injection rate of 1 mL/h. It also showed the highest humidity sensitivity among the other prepared SAW devices. PMID:27916870

  10. Spraying modes in coaxial jet electrospray with outer driving liquid

    NASA Astrophysics Data System (ADS)

    Chen, Xiaopeng; Jia, Laibing; Yin, Xiezhen; Cheng, Jiusheng; Lu, Jian

    2005-03-01

    Coaxial jet electrospray is a technique to generate microencapsules, which uses electric forces to create a coaxial microjet from two immiscible liquids. Compound droplets with narrow size distribution are produced after the jet breaks up. In this paper, the spraying modes are investigated experimentally with proper flow rates of the inner and outer liquids. Ethanol/glycerol/tween mixture (outer liquid) and cooking oil (inner liquid) are fed into the gap between outer and inner capillaries and the inner capillary, respectively. The spraying modes presented in our experiments are "dripping mode," "dripping mode in spindle," "cone-jet mode," "pulse mode in cone," and "multijets mode" sequentially, as the applied voltage increases. The region of stable cone-jet mode extends with decrease of the outer liquid flow rate and increase of the inner one. It is found that the spray phenomena are mainly determined by properties of the outer liquid, which is viscous and electric conductive enough. A rudimentary physical model is developed, in which both the viscosity and liquid interface tension are taken into account.

  11. Is electrospray emission really due to columbic forces?

    SciTech Connect

    Aliotta, Francesco Ponterio, Rosina C.; Salvato, Gabriele; Vasi, Cirino; Calandra, Pietro; Pochylski, Mikolaj

    2014-09-15

    Electrospray ionization (ESI) is a widely adopted soft ionization method for mass spectroscopy (MS). In spite of the undeniable success of the technique, its mechanisms are difficult to be analytically modelled because the process is characterized by non-equilibrium conditions. The common belief is that the formation of gas-phase ions takes place at the apex of the Taylor cone via electrophoretic charging. The charge balance implies that a conversion of electrons to ions should occur at the metal-liquid interface of the injector needle. We have detected that the above description is based on unproved assumptions which are not consistent with the correct evaluation of the problem. The comparison between experiments performed under the usual geometry and observations obtained under symmetric field configurations suggests that the emitted droplets cannot be significantly charged or, at least, that any possible ionization mechanism is so poorly efficient to ensure that columbic forces cannot play a major role in jet formation, even in cases where the liquid consists of a solution of ionic species. Further work is required to clearly understand how ionization occurs in ESI-MS.

  12. Application and Analysis of Biological Electrospray in Tissue Engineering

    PubMed Central

    Yunmin, Ma; Yuanyuan, Liu; Haiping, Chen; Qingxi, Hu

    2015-01-01

    Nan-fiber scaffolds are suitable tools for tissue engineering. Electro spinning materials together with cells presents not adequate to obtain a high cellular zing tissue constructs as the shear force, tensile force, and other physical effects excited in the electro spinning process, which are harmful to cellular differentiation, development and function. However, this limitation has been overcome by a micro integration system of simultaneously bio-electro spraying human adipose stem cells (ASCs) and electro spinning Polyvinyl alcohol (PVA). Then it was compared to the single electro spinning nan-fiber scaffolds in relation to cell viability, which showed that the scaffolds by micro integration approach has a larger number of surviving cells and more suitable for cell growth and proliferation. In addition, the relationship between different parameters of biological electrospray (voltage, flow rate and distance of the needle from the collecting board) and droplet size of cell suspension was elucidated and the droplets with a near-mono distribution (<50um) could be generated to deposit a single living cell within a droplet. The association of bio-electro spraying with electro spinning (a scaffold preparation technique) has been demonstrated to be a promising and suitable tissue engineering approach in producing nan-fiber based three-dimensional (3-D) cell seeded scaffolds. PMID:26089992

  13. Electrospray ionization tandem mass spectrometry of ammonium cationized polyethers.

    PubMed

    Nasioudis, Andreas; Heeren, Ron M A; van Doormalen, Irene; de Wijs-Rot, Nicolette; van den Brink, Oscar F

    2011-05-01

    Quaternary ammonium salts (Quats) and amines are known to facilitate the MS analysis of high molar mass polyethers by forming low charge state adduct ions. The formation, stability, and behavior upon collision-induced dissociation (CID) of adduct ions of polyethers with a variety of Quats and amines were studied by electrospray ionization quadrupole time-of-flight, quadrupole ion trap, and linear ion trap tandem mass spectrometry (MS/MS). The linear ion trap instrument was part of an Orbitrap hybrid mass spectrometer that allowed accurate mass MS/MS measurements. The Quats and amines studied were of different degree of substitution, structure, and size. The stability of the adduct ions was related to the structure of the cation, especially the amine's degree of substitution. CID of singly/doubly charged primary and tertiary ammonium cationized polymers resulted in the neutral loss of the amine followed by fragmentation of the protonated product ions. The latter reveals information about the monomer unit, polymer sequence, and endgroup structure. In addition, the detection of product ions retaining the ammonium ion was observed. The predominant process in the CID of singly charged quaternary ammonium cationized polymers was cation detachment, whereas their doubly charged adduct ions provided the same information as the primary and tertiary ammonium cationized adduct ions. This study shows the potential of specific amines as tools for the structural elucidation of high molar mass polyethers.

  14. Electrospray Ionization Tandem Mass Spectrometry of Ammonium Cationized Polyethers

    NASA Astrophysics Data System (ADS)

    Nasioudis, Andreas; Heeren, Ron M. A.; van Doormalen, Irene; de Wijs-Rot, Nicolette; van den Brink, Oscar F.

    2011-05-01

    Quaternary ammonium salts (Quats) and amines are known to facilitate the MS analysis of high molar mass polyethers by forming low charge state adduct ions. The formation, stability, and behavior upon collision-induced dissociation (CID) of adduct ions of polyethers with a variety of Quats and amines were studied by electrospray ionization quadrupole time-of-flight, quadrupole ion trap, and linear ion trap tandem mass spectrometry (MS/MS). The linear ion trap instrument was part of an Orbitrap hybrid mass spectrometer that allowed accurate mass MS/MS measurements. The Quats and amines studied were of different degree of substitution, structure, and size. The stability of the adduct ions was related to the structure of the cation, especially the amine's degree of substitution. CID of singly/doubly charged primary and tertiary ammonium cationized polymers resulted in the neutral loss of the amine followed by fragmentation of the protonated product ions. The latter reveals information about the monomer unit, polymer sequence, and endgroup structure. In addition, the detection of product ions retaining the ammonium ion was observed. The predominant process in the CID of singly charged quaternary ammonium cationized polymers was cation detachment, whereas their doubly charged adduct ions provided the same information as the primary and tertiary ammonium cationized adduct ions. This study shows the potential of specific amines as tools for the structural elucidation of high molar mass polyethers.

  15. Electrospray deposition of organic molecules on bulk insulator surfaces.

    PubMed

    Hinaut, Antoine; Pawlak, Rémy; Meyer, Ernst; Glatzel, Thilo

    2015-01-01

    Large organic molecules are of important interest for organic-based devices such as hybrid photovoltaics or molecular electronics. Knowing their adsorption geometries and electronic structures allows to design and predict macroscopic device properties. Fundamental investigations in ultra-high vacuum (UHV) are thus mandatory to analyze and engineer processes in this prospects. With increasing size, complexity or chemical reactivity, depositing molecules by thermal evaporation becomes challenging. A recent way to deposit molecules in clean conditions is Electrospray Ionization (ESI). ESI keeps the possibility to work with large molecules, to introduce them in vacuum, and to deposit them on a large variety of surfaces. Here, ESI has been successfully applied to deposit triply fused porphyrin molecules on an insulating KBr(001) surface in UHV environment. Different deposition coverages have been obtained and characterization of the surface by in-situ atomic force microscopy working in the non-contact mode shows details of the molecular structures adsorbed on the surface. We show that UHV-ESI, can be performed on insulating surfaces in the sub-monolayer regime and to single molecules which opens the possibility to study a variety of complex molecules.

  16. Next Generation of Electrosprayed Fibers for Tissue Regeneration

    PubMed Central

    Hong, Jong Kyu

    2011-01-01

    Electrospinning is a widely established polymer-processing technology that allows generation of fibers (in nanometer to micrometer size) that can be collected to form nonwoven structures. By choosing suitable process parameters and appropriate solvent systems, fiber size can be controlled. Since the technology allows the possibility of tailoring the mechanical properties and biological properties, there has been a significant effort to adapt the technology in tissue regeneration and drug delivery. This review focuses on recent developments in adapting this technology for tissue regeneration applications. In particular, different configurations of nozzles and collector plates are summarized from the view of cell seeding and distribution. Further developments in obtaining thick layers of tissues and thin layered membranes are discussed. Recent advances in porous structure spatial architecture parameters such as pore size, fiber size, fiber stiffness, and matrix turnover are summarized. In addition, possibility of developing simple three-dimensional models using electrosprayed fibers that can be utilized in routine cell culture studies is described. PMID:21210761

  17. [Theory and practice of electrospray crystallization in particle size reduction].

    PubMed

    Szunyogh, Tímea; Ambrus, Rita; Szabóné Révész, Piroska

    2015-01-01

    Nowdays, one of the most challenges for the researchers is the formulation of poorly water soluble drugs. Reduction of particle size of active agents to submicron range could result in a faster dissolution rate and higher bioavailability. Integration as crystallization process is an often used particle size decreasing technique. The aim of this study was to show the theoretical background and practical application of the electros pray crystallization as an innovative particle size decreasing technique. Our model drug was the niflumic acid (NIF), which belongs to the BCS Class II. After the optimization of the process parameters, the physico-chemical properties of the samples were characterized. Particle size and shape were visualized by scanning electron microscopy (SEM). Crystalline state of NIF and the samples were investigated using differential scanning calorimetry (DSC) and X-ray powder diffraction. Physico-chemical properties were determined using dissolution test from simulated media. The electrospray crytallization resulted in particle size reduction but the aggregation of nanonized NIF crystals (NIF-nano) could not avoid without excipient. Aggregates with poor secondary forces are suitable for production of the interactive physical mixture. It was found that NIF-nano could be well distributed on the surface of the mannitol as carrier and the Poloxamer R protected the NIF-nano crystals (320 nm)from aggregation. Consequently, the physical mixture resulted in product with higher polarity, better wettability and faster dissolution rate of NIF as raw NIF or NIF-nano.

  18. Electrospray ionization mass spectrometric characterization of acrylamide adducts to hemoglobin

    SciTech Connect

    Springer, D.L.; Goheen, S.C.; Edmonds, C.G. ); Bull, R.J.; Sylvester, D.M. )

    1993-01-01

    The most common procedure to identify hemoglobin adducts has been to cleave the adducts from the protein and characterize the adducting species, by, for example, derivatization and gas chromatography/mass spectrometry. To extend these approaches we used electrospray ionization mass spectrometry (ESI-MS) to characterize adducted hemoglobin. For this we incubated [[sup 14]C]acrylamide with the purified human hemoglobin (type A[sub 0]) under conditions that yielded high adduct levels. When the hemoglobin was separated by reversed-phase high-performance liquid chromatography (HPLC), 65% of the radioactivity copurified with the [beta]-subunit. Three adducted species were prominent in the ESI mass spectrum of the intact [beta]-subunit, indicating acrylamide adduction (i.e., mass increase of 71 Da) and two addition unidentified moieties with mass increments of 102 and 135 Da. Endoproteinase Glu-C digestion of the adducted [beta]-subunit resulted in a peptide mixture that, upon reversed-phase HPLC separation, provided several radiolabeled peptides. Using ESI-MS we identified these as the V[sub 91-101] and V[sub 102-122] peptides that represent the cysteine-containing peptides of the [beta]-subunit. These results provide definitive information on acrylamide-modified human hemoglobin and demonstrate that ESI-MS provides valuable structure information on chemically adducted proteins. 30 refs., 9 figs., 3 tabs.

  19. Advances in drug delivery via electrospun and electrosprayed nanomaterials

    PubMed Central

    Zamani, Maedeh; Prabhakaran, Molamma P; Ramakrishna, Seeram

    2013-01-01

    Electrohydrodynamic (EHD) techniques refer to procedures that utilize electrostatic forces to fabricate fibers or particles of different shapes with sizes in the nano-range to a few microns through electrically charged fluid jet. Employing different techniques, such as blending, surface modification, and coaxial process, there is a great possibility of incorporating bioactive such molecules as drugs, DNA, and growth factors into the nanostructures fabricated via EHD techniques. By careful selection of materials and processing conditions, desired encapsulation efficiency as well as preserved bioactivity of the therapeutic agents can be achieved. The drug-loaded nanostructures produced can be applied via different routes, such as implantation, injection, and topical or oral administration for a wide range of disease treatment. Taking advantage of the recent developments in EHD techniques like the coaxial process or multilayered structures, individually controlled delivery of multiple drugs is achievable, which is of great demand in cancer therapy and growth-factor delivery. This review summarizes the most recent techniques and postmodification methods to fabricate electrospun nanofibers and electrosprayed particles for drug-delivery applications. PMID:23976851

  20. A high-frequency electrospray driven by gas volume charges

    SciTech Connect

    Lastochkin, Dmitri; Chang, H.-C.

    2005-06-15

    High-frequency (>10 kHz) ac electrospray is shown to eject volatile dielectric liquid drops by an entirely different mechanism from dc sprays. The steady dc Taylor conic tip is absent and continuous spraying of submicron drops is replaced by individual dynamic pinchoff events involving the entire drop. We attribute this spraying mechanism to a normal Maxwell force produced by an undispersed plasma cloud in front of the meniscus that produces a visible glow at the spherical tip. The volume charge within the cloud is formed by electron-induced gas ionization of the evaporated liquid and produces a large normal field that is much higher than the nominal applied field such that drop ejection occurs at a voltage (at high frequencies) that is as much as ten times lower than that for dc sprays. The ejection force is sensitive to the liquid properties (but not its electrolyte composition), the ac frequency and trace amounts of inert gases, which are believed to catalyze the ionization reactions. As electroneutral drops are ejected, due to the large (>100) ratio between individual drop ejection time and the ac frequency, this mechanism can produce large (microns) electroneutral drops at relatively low voltages.

  1. Electrochemistry combined on-line with electrospray mass spectrometry

    SciTech Connect

    Zhou, F.; Berkel, G.J.V.

    1995-10-15

    In this paper a variety of methods to couple electrochemistry on-line with electrospray mass spectrometry (EC/ES-MS) are presented, and the fundamental and analytical utility of this hybrid technique is illustrated. The major problems encountered in coupling EC and ES-MS are discussed, and means to overcome them are presented. Three types of electrochemical flow cells, viz., a thin-layer electrode flow-by cell, a tubular electrode flow-through cell, and a porous electrode flow-through cell, are discussed in regard to their suitability for this coupling. Methods for coupling each of these electrochemical cells on-line with ES-MS, either floated at or decoupled from the ES high voltage and controlled by a constant current supply, a constant potential supply, or a potentiostat are presented. Three applications are used to illustrate the utility and versatility of the EC/ES-MS combination: (1) the ionization of neutral analytes (i.e., perylene) for detection by ES-MS, (2) the study of the products of electrode reactions (i.e., nickel(II) octaethylporphyrin oxidation products), including relatively short-lived products (i.e., {Beta}-carotene oxidation products), and (3) the enhanced determination of metals (i.e., elemental silver) achieved by coupling anodic stripping voltammetry on-line with ES-MS. 52 refs., 6 figs.

  2. Electrospray of multifunctional microparticles for image-guided drug delivery

    NASA Astrophysics Data System (ADS)

    Zhang, Leilei; Yan, Yan; Mena, Joshua; Sun, Jingjing; Letson, Alan; Roberts, Cynthia; Zhou, Chuanqing; Chai, Xinyu; Ren, Qiushi; Xu, Ronald

    2012-03-01

    Anti-VEGF therapies have been widely explored for the management of posterior ocular disease, like neovascular age-related macular degeneration (AMD). Loading anti-VEGF therapies in biodegradable microparticles may enable sustained drug release and improved therapeutic outcome. However, existing microfabrication processes such as double emulsification produce drug-loaded microparticles with low encapsulation rate and poor antibody bioactivity. To overcome these limitations, we fabricate multifunctional microparticles by both single needle and coaxial needle electrospray. The experimental setup for the process includes flat-end syringe needles (both single needle and coaxial needle), high voltage power supplies, and syringe pumps. Microparticles are formed by an electrical field between the needles and the ground electrode. Droplet size and morphology are controlled by multiple process parameters and material properties, such as flow rate and applied voltage. The droplets are collected and freezing dried to obtain multifunctional microparticles. Fluorescent beads encapsulated poly(DL-lactide-co-glycolide) acid (PLGA) microparticles are injected into rabbits eyes through intravitreal injection to test the biodegradable time of microparticles.

  3. Electrospray deposition of organic molecules on bulk insulator surfaces

    PubMed Central

    Pawlak, Rémy; Glatzel, Thilo

    2015-01-01

    Summary Large organic molecules are of important interest for organic-based devices such as hybrid photovoltaics or molecular electronics. Knowing their adsorption geometries and electronic structures allows to design and predict macroscopic device properties. Fundamental investigations in ultra-high vacuum (UHV) are thus mandatory to analyze and engineer processes in this prospects. With increasing size, complexity or chemical reactivity, depositing molecules by thermal evaporation becomes challenging. A recent way to deposit molecules in clean conditions is Electrospray Ionization (ESI). ESI keeps the possibility to work with large molecules, to introduce them in vacuum, and to deposit them on a large variety of surfaces. Here, ESI has been successfully applied to deposit triply fused porphyrin molecules on an insulating KBr(001) surface in UHV environment. Different deposition coverages have been obtained and characterization of the surface by in-situ atomic force microscopy working in the non-contact mode shows details of the molecular structures adsorbed on the surface. We show that UHV-ESI, can be performed on insulating surfaces in the sub-monolayer regime and to single molecules which opens the possibility to study a variety of complex molecules. PMID:26665062

  4. pH Effects on Electrospray Ionization Efficiency

    NASA Astrophysics Data System (ADS)

    Liigand, Jaanus; Laaniste, Asko; Kruve, Anneli

    2016-12-01

    Electrospray ionization efficiency is known to be affected by mobile phase composition. In this paper, a detailed study of analyte ionization efficiency dependence on mobile phase pH is presented. The pH effect was studied on 28 compounds with different chemical properties. Neither pK a nor solution phase ionization degree by itself was observed to be sufficient at describing how aqueous phase pH affects the ionization efficiency of the analyte. Therefore, the analyte behavior was related to various physicochemical properties via linear discriminant analyses. Distinction between pH-dependent and pH-independent compounds was achieved using two parameters: number of potential charge centers and hydrogen bonding acceptor capacity (in the case of 80% acetonitrile) or polarity of neutral form of analyte and pK a (in the case of 20% acetonitrile). It was also observed that decreasing pH may increase ionization efficiency of a compound by more than two orders of magnitude.

  5. Deployment of a Curved Truss

    NASA Technical Reports Server (NTRS)

    Giersch, Louis R.; Knarr, Kevin

    2010-01-01

    Structures capable of deployment into complex, three-dimensional trusses have well known space technology applications such as the support of spacecraft payloads, communications antennas, radar reflectors, and solar concentrators. Such deployable trusses could also be useful in terrestrial applications such as the rapid establishment of structures in military and emergency service situations, in particular with regard to the deployment of enclosures for habitat or storage. To minimize the time required to deploy such an enclosure, a single arch-shaped truss is preferable to multiple straight trusses arranged vertically and horizontally. To further minimize the time required to deploy such an enclosure, a synchronous deployment with a single degree of freedom is also preferable. One method of synchronizing deployment of a truss is the use of a series of gears; this makes the deployment sequence predictable and testable, allows the truss to have a minimal stowage volume, and the deployed structure exhibits the excellent stiffness-to-mass and strength-to-mass ratios characteristic of a truss. A concept for using gears with varying ratios to deploy a truss into a curved shape has been developed and appears to be compatible with both space technology applications as well as potential use in terrestrial applications such as enclosure deployment. As is the case with other deployable trusses, this truss is formed using rigid elements (e.g., composite tubes) along the edges, one set of diagonal elements composed of either cables or folding/hinged rigid members, and the other set of diagonal elements formed by a continuous cable that is tightened by a motor or hand crank in order to deploy the truss. Gears of varying ratios are used to constrain the deployment to a single degree of freedom, making the deployment synchronous, predictable, and repeatable. The relative sizes of the gears and the relative dimensions of the diagonal elements determine the deployed geometry (e

  6. Selective and sensitive detection of chromium(VI) in waters using electrospray ionization mass spectrometry.

    PubMed

    Weldy, Effie; Wolff, Chloe; Miao, Zhixin; Chen, Hao

    2013-09-01

    From 2000 through 2011, there were 14 criminal cases of violations of the Clean Water Act involving the discharge of chromium, a toxic heavy metal, into drinking and surface water sources. As chromium(VI), a potential carcinogen present in the environment, represents a significant safety concern, it is currently the subject of an EPA health risk assessment. Therefore, sensitive and selective detection of this species is highly desired. This study reports the analysis of chromium(VI) in water samples by electrospray ionization mass spectrometry (ESI-MS) following its reduction and complexation with ammonium pyrrolidinedithiocarbamate (APDC). The reduction and subsequent complexation produce a characteristic [Cr(III)O]-PDC complex which can be detected as a protonated ion of m/z 507 in the positive ion mode. The detection is selective to chromium(VI) under acidic pH, even in the presence of chromium(III) and other metal ions, providing high specificity. Different water samples were examined, including deionized, tap, and river waters, and sensitive detection was achieved. In the case of deionized water, quantification over the concentration range of 3.7 to 148ppb gave an excellent correlation coefficient of 0.9904 using the enhanced MS mode scan. Using the single-reaction monitoring (SRM) mode (monitoring the characteristic fragmentation of m/z 507 to m/z 360), the limit of detection (LOD) was found to be 0.25ppb. The LOD of chromium(VI) for both tap and river water samples was determined to be 2.0ppb. A preconcentration strategy using simple vacuum evaporation of the aqueous sample was shown to further improve the ESI signal by 15 fold. This method, with high sensitivity and selectivity, should provide a timely solution for the real-world analysis of toxic chromium(VI).

  7. Quantitative comparison of a flared and a standard heated metal capillary inlet with a voltage-assisted air amplifier on an electrospray ionization linear ion trap mass spectrometer.

    PubMed

    Dixon, R Brent; Muddiman, David C

    2007-01-01

    The performance characteristics (i.e., ion abundance and electrospray ion current) of a flared and blunt-ended heated metal capillary were evaluated with a voltage-assisted air amplifier on a linear ion trap mass spectrometer (LTQ-MS). The results demonstrated that a standard capillary afforded higher ion abundance than a flared capillary, thus further work is necessary to investigate conditions for which significant benefits with the flared capillary will be observed. The compatibility of a voltage-assisted air amplifier is explored for both types of capillaries and in all cases resulted in improved ion abundance and spray current.

  8. Electrospray Encapsulation of Toll-Like Receptor Agonist Resiquimod in Polymer Microparticles for the Treatment of Visceral Leishmaniasis

    DTIC Science & Technology

    2013-01-15

    ultrasonic atom- ization,20 and impact-jet atomization,21 in this study we chose to use electrohydrodynamic spraying22,23 (electrospray) to produce the Ac...of such an apparatus by operating an array of electrospray nozzles in parallel, which is referred to as multiplexed electrospray.18,24,25 We used a...3% (w/ v) poly(vinyl alcohol) (PVA). The mixture was vortexed for 30 min and sonicated for 30 s (Misonix Ultrasonic Liquid Processor, 60 W, duty

  9. Curved-channel microchannel array plates. [photoelectric detectors

    NASA Technical Reports Server (NTRS)

    Timothy, J. G.

    1981-01-01

    The microchannel array plate (MCP) is a photoelectric detector with an imaging capability comparable to that of a photographic plate. Recently MCPs in which the channels are curved to inhibit ion feedback have become available. These devices represent a major advance in MCP technology, since a single curved-channel MCP can be operated stably at high gain in the pulse-counting mode without any of the problems of stability of response or short lifetime reported for 'chevron' MCP detectors. Attention is given to the mode of operation of channel electron multipliers (CEM) and MCP, curved-channel MCP, test procedures, and performance characteristics. The accumulated test data show that the fundamental operating characteristics of the curved-channel MCP are directly related to those for the CEM.

  10. Development and validation of an ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry method for the simultaneous determination of selected flavonoids in Ginkgo biloba.

    PubMed

    Pandey, Renu; Chandra, Preeti; Arya, Kamal Ram; Kumar, Brijesh

    2014-12-01

    A rapid and sensitive ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry method was developed and validated for the simultaneous determination of 13 flavonoids in leaf, stem, and fruit extracts of male and female trees of Ginkgo biloba to investigate gender- and age-related variations of flavonoids content. Chromatographic separation was accomplished on an Acquity UPLC BEH C18 column (50 mm × 2.1 mm id, 1.7 μm) in 5 min. Quantitation was performed using negative electrospray ionization mass spectrometry in multiple reaction monitoring mode. The calibration curves of all analytes showed a good linear relationship (r(2) ≥ 0.9977) over the concentration range of 1-1000 ng/mL. The precision evaluated by an intra- and interday study showed RSD ≤ 1.98% and good accuracy with overall recovery in the range from 97.90 to 101.09% (RSD ≤ 1.67%) for all analytes. The method sensitivity expressed as the limit of quantitation was typically 0.25-3.57 ng/mL. The results showed that the total content of 13 flavonoids was higher in the leaf extract of an old male Ginkgo tree compared to young female Ginkgo trees.

  11. Development of a liquid chromatography-electrospray ionization-tandem mass spectrometry method for the simultaneous analysis of intact glucosinolates and isothiocyanates in Brassicaceae seeds and functional foods.

    PubMed

    Franco, P; Spinozzi, S; Pagnotta, E; Lazzeri, L; Ugolini, L; Camborata, C; Roda, A

    2016-01-08

    A new high pressure liquid chromatography-electrospray ionization-tandem mass spectrometry method for the simultaneous determination of glucosinolates, as glucoraphanin and glucoerucin, and the corresponding isothiocyanates, as sulforaphane and erucin, was developed and applied to quantify these compounds in Eruca sativa defatted seed meals and enriched functional foods. The method involved solvent extraction, separation was achieved in gradient mode using water with 0.5% formic acid and acetonitrile with 0.5% formic acid and using a reverse phase C18 column. The electrospray ion source operated in negative and positive mode for the detection of glucosinolates and isothiocyanates, respectively, and the multiple reaction monitoring (MRM) was selected as acquisition mode. The method was validated following the ICH guidelines. Replicate experiments demonstrated a good accuracy (bias%<10%) and precision (CV%<10%). Detection limits and quantification limits are in the range of 1-400ng/mL for each analytes. Calibration curves were validated on concentration ranges from 0.05 to 50μg/mL. The method proved to be suitable for glucosinolates and isothiocyanates determination both in biomasses and in complex matrices such as food products enriched with glucosinolates, or nutraceutical bakery products. In addition, the developed method was applied to the simultaneous determination of glucosinolates and isothiocyanates in bakery product enriched with glucosinolates, to evaluate their thermal stability after different industrial processes from cultivation phases to consumer processing.

  12. Determination of alprostadil in rat plasma by ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry after intravenous administration.

    PubMed

    Lin, Xia; Zhang, Yu; Cui, Yue; Wang, Lin; Wang, Jing; Tang, Xing

    2009-05-01

    A rapid, highly selective ultra performance liquid chromatography-electrospray ionisation-tandem mass spectrometry method (UPLC-ESI-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of alprostadil in rat plasma. After a simple sample preparation procedure involving a one-step liquid-liquid extraction, alprostadil and the internal standard, diphenhydramine, were chromatographed on an ACQUITY UPLC BEH C(18) column with gradient elution using a mobile phase consisting of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.25 mL min(-1). The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring (MRM) mode via an electrospray ionization (ESI) source. The calibration curve was linear (r(2)=0.99) over the concentration range 0.4-250.0 ng mL(-1), with a lower limit of quantification of 0.4 ng mL(-1) for alprostadil. The inter- and intra-day precision (%R.S.D.) was less than 8.5% and 2.4%, respectively, and the accuracy (RE%) was between 9.3% and 1.0% (n=6). Alprostadil in rat plasma was stable when stored at room temperature for 0.5h and at -20 degrees C for two weeks. The method was very rapid, simple and reliable, and was employed for the first time for the pharmacokinetic studies of alprostadil in rats after a single intravenous administration of 50 microg kg(-1).

  13. Gas-phase dissociation of ionic liquid aggregates studied by electrospray ionisation mass spectrometry and energy-variable collision induced dissociation.

    PubMed

    Fernandes, Ana M; Coutinho, João A P; Marrucho, Isabel M

    2009-01-01

    Positive singly charged ionic liquid aggregates [(C(n)mim)(m+1)(BF(4))(m)](+) (mim = 3-methylimidazolium; n = 2, 4, 8 and 10) and [(C(4)mim)(m+1)(A)(m)](+) (A = Cl(-), BF(4) (-), PF(6) (-), CF(3)SO(3) (-) and (CF(3)SO(2))(2)N(-)) were investigated by electrospray ionisation mass spectrometry and energy-variable collision induced dissociation. The electrospray ionisation mass spectra (ESI-MS) showed the formation of an aggregate with extra stability for m = 4 for all the ionic liquids with the exception of [C(4)mim][CF(3)SO(3)]. ESI-MS-MS and breakdown curves of aggregate ions showed that their dissociation occurred by loss of neutral species ([C(n)mim][A])(a) with a >or= 1. Variable-energy collision induced dissociation of each aggregate from m = 1 to m = 8 for all the ionic liquids studied enabled the determination of E(cm, 1/2) values, whose variation with m showed that the monomers were always kinetically much more stable than the larger aggregates, independently of the nature of cation and anion. The centre-of-mass energy values correlate well with literature data on ionic volumes and interaction and hydrogen bond energies.

  14. Accelerating Around an Unbanked Curve

    DTIC Science & Technology

    2006-02-01

    FEB 2006 2. REPORT TYPE 3. DATES COVERED 00-00-2006 to 00-00-2006 4. TITLE AND SUBTITLE Accelerating Around an Unbanked Curve 5a. CONTRACT...December 2004 issue of TPT presented a problem concerning how a car should acceler-ate around an unbanked curve of constant radius r starting from rest...Accelerating Around an Unbanked Curve Carl E. Mungan, U.S. Naval Academy, Annapolis, MD 100 THE PHYSICS TEACHER ◆ Vol. 44, February 2006 The shapes

  15. Curved conveyor section guide assembly

    SciTech Connect

    Truszczinski, H.

    1981-02-03

    A guide assembly for a curved conveyor section of a scraperchain conveyor guides the scraper assembly from a first straight conveyor portion round the curved conveyor section to a second straight conveyor portion. This guiding is accomplished by a pair of independently rotatable pulley wheels. A further pair of independently rotatable pulley wheels are provided to guide the drive chain of a plough round the curved conveyor section. This enables the plough to be driven to and fro along the first straight conveyor portion by a drive station attached to the second straight conveyor portion adjacent to the guide assembly.

  16. Novel electrosprayed nanospherules for enhanced aqueous solubility and oral bioavailability of poorly water-soluble fenofibrate

    PubMed Central

    Yousaf, Abid Mehmood; Mustapha, Omer; Kim, Dong Wuk; Kim, Dong Shik; Kim, Kyeong Soo; Jin, Sung Giu; Yong, Chul Soon; Youn, Yu Seok; Oh, Yu-Kyoung; Kim, Jong Oh; Choi, Han-Gon

    2016-01-01

    Purpose The purpose of the present research was to develop a novel electrosprayed nanospherule providing the most optimized aqueous solubility and oral bioavailability for poorly water-soluble fenofibrate. Methods Numerous fenofibrate-loaded electrosprayed nanospherules were prepared with polyvinylpyrrolidone (PVP) and Labrafil® M 2125 as carriers using the electrospray technique, and the effect of the carriers on drug solubility and solvation was assessed. The solid state characterization of an optimized formulation was conducted by scanning electron microscopy, powder X-ray diffraction, differential scanning calorimetry, and Fourier transform infrared spectroscopic analyses. Oral bioavailability in rats was also evaluated for the formulation of an optimized nanospherule in comparison with free drug and a conventional fenofibrate-loaded solid dispersion. Results All of the electrosprayed nanospherule formulations had remarkably enhanced aqueous solubility and dissolution compared with free drug. Moreover, Labrafil M 2125, a surfactant, had a positive influence on the solubility and dissolution of the drug in the electrosprayed nanospherule. Increases were observed as the PVP/drug ratio increased to 4:1, but higher ratios gave no significant increases. In particular, an electrosprayed nanospherule composed of fenofibrate, PVP, and Labrafil M 2125 at the weight ratio of 1:4:0.5 resulted in a particle size of <200 nm with the drug present in the amorphous state. It demonstrated the highest solubility (32.51±2.41 μg/mL), an excellent dissolution (~85% in 10 minutes), and an oral bioavailability ~2.5-fold better than that of the free drug. It showed similar oral bioavailability compared to the conventional solid dispersion. Conclusion Electrosprayed nanospherules, which provide improved solubility and bioavailability, are promising drug delivery tools for oral administration of poorly water-soluble fenofibrate. PMID:26834471

  17. Formation of enriched black tea extract loaded chitosan nanoparticles via electrospraying

    NASA Astrophysics Data System (ADS)

    Hammond, Samuel James

    Creating nanoparticles of beneficial nutraceuticals and pharmaceuticals has had a large surge of research due to the enhancement of absorption and bioavailability by decreasing their size. One of these ways is by electrohydrodynamic atomization, also known as electrospraying. In general, this novel process is done by forcing a liquid through a capillary nozzle and which is subjected to an electrical field. While there are different ways to create nanoparticles, the novel method of electrospraying can be beneficial over other types of nanoparticle formation. Reasons include high control over particle size and distribution by altering electrospray parameters (voltage, flow rate, distance, and time), higher encapsulation efficiency than other methods, and also it is a one step process without exposure to extreme conditions (Gomez-Estaca et. al. 2012, Jaworek and Sobcyzk 2008). The current study aimed to create a chitosan encapsulated theaflavin-2 enriched black tea extract (BTE) nanoparticles via electrospraying. The first step of this process was to create the smallest chitosan nanoparticles possible by altering the electrospray parameters and the chitosan-acetic acid solution parameters. The solution properties altered include chitosan molecular weight, acetic acid concentration, and chitosan concentration. Specifically, the electrospray parameters such as voltage, flow rate and distance from syringe to collector are the most important in determining particle size. After creating the smallest chitosan particles, the TF-2 enriched black tea extract was added to the chitosan-acetic acid solution to be electrosprayed. The particles were assessed with the following procedures: Atomic force microscopy (AFM) and scanning electron microscopy (SEM) for particle morphology and size, and loading efficiency with ultraviolet--visible spectrophotometer (UV-VIS). Chitosan-BTE nanoparticles were successfully created in a one step process. Diameter of the particles on average

  18. Fast imaging of intermittent electrospraying of water with positive corona discharge

    NASA Astrophysics Data System (ADS)

    Pongrác, B.; Kim, H. H.; Janda, M.; Martišovitš, V.; Machala, Z.

    2014-08-01

    The effect of the electrospraying of water in combination with a positive direct current (dc) streamer corona discharge generated in air was investigated in this paper. We employed high-speed camera visualizations and oscilloscopic discharge current measurements in combination with an intensified charge-coupled device camera for fast time-resolved imaging. The repetitive process of Taylor cone formation and droplet formation from the mass fragments of water during the electrospray was visualized. Depending on the applied voltage, the following intermittent modes of electrospraying typical for water were observed: dripping mode, spindle mode, and oscillating-spindle mode. The observed electrospraying modes were repetitive with a frequency of a few hundreds of Hz, as measured from the fast image sequences. This frequency agreed well with the frequency of the measured streamer current pulses. The presence of filamentary streamer discharges at relatively low voltages probably prevented the establishment of a continuous electrospray in the cone-jet mode. After each streamer, a positive glow corona discharge was established on the water filament tip, and it propagated from the stressed electrode along with the water filament elongation. The results show a reciprocal character of intermittent electrospraying of water, and the presence of corona discharge, where both the electrospray and the discharge affect each other. The generation of a corona discharge from the water cone depended on the repetitive process of the cone formation. Also, the propagation and curvature of the water filament were influenced by the discharge and its resultant space charge. Furthermore, these phenomena were partially influenced by the water conductivity.

  19. Remarks of Elliptic Curves Derived from Ant Colony Routing

    NASA Astrophysics Data System (ADS)

    Jung, Sangsu; Kim, Daeyeoul; Singh, Dhananjay

    2011-09-01

    We deal with an ant colony based routing model for wireless multi-hop networks. Our model adopts an elliptic curve equation, which is beneficial to design pheromone dynamics for load balancing and packet delivery robustness. Due to the attribute of an elliptic curve equation, our model prevents the over-utilization of a specific node, distinctively from conventional ant colony based schemes. Numerical simulations exhibit the characteristics of our model with respect to various parameters.

  20. Propagation of waves of acoustic frequencies in curved ducts

    NASA Technical Reports Server (NTRS)

    Rostafinski, W.

    1973-01-01

    The propagation of waves of acoustic frequencies in curved ducts is studied for the first four modes. The analysis makes use of Bessel functions to construct curves of wave number in the duct versus imposed wave number. The results apply to ducts of arbitrary width and arbitrary radii of curvature. The characteristics of motion in a bend are compared with propagation of waves in a straight duct, and important differences in the behavior of waves are noted.

  1. Electromagnetic propagation in PEC and absorbing curved S-ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1988-01-01

    A finite-element Galerkin formulation has been developed to study transverse magnetic (TM) wave propagation in 2-D S-curved ducts with both perfectly conducting and absorbing walls. The reflection and transmission at the entrances and the exits of the curved ducts are determined by coupling the finite-element solutions in the curved ducts to the eigenfunctions of an infinite, uniform, perfectly conducting duct. Example solutions are presented for a double mitred and S-ducts of various lengths. The length of the S-duct is found to significantly effect the reflective characteristics of the duct. Also, the effect of curvature on an absorbing duct is illustrated.

  2. Flow over riblet curved surfaces

    NASA Astrophysics Data System (ADS)

    Loureiro, J. B. R.; Silva Freire, A. P.

    2011-12-01

    The present work studies the mechanics of turbulent drag reduction over curved surfaces by riblets. The effects of surface modification on flow separation over steep and smooth curved surfaces are investigated. Four types of two-dimensional surfaces are studied based on the morphometric parameters that describe the body of a blue whale. Local measurements of mean velocity and turbulence profiles are obtained through laser Doppler anemometry (LDA) and particle image velocimetry (PIV).

  3. Electrospray ionization mass spectrometry and its environmental applications

    SciTech Connect

    Long, J.M.

    1993-01-01

    An electrospray ionization (ESI) source was designed, fabricated and then installed on a VG TRIO-2 quadrupole mass spectrometer. A gold coated 50-[mu]m fused silica capillary was used instead of the conventional stainless steel needle. Analytes are desorbed into the gas phase via a heated metal transport capillary and are focused through a set of five electrostatic lenses into the analyzer region of the mass spectrometer. Environmentally significant compounds such as pesticides and herbicides that are polar, nonvolatile and thermally labile are not readily analyzed by conventional gas chromatography/mass spectrometry (GC/MS). Thirty pesticides from the 13 classes of carbamate, organophosphorus, organochlorine, bipyridyl, phthalimide, urea, carboxyllic acid, hydroxycoumarin, triazine, indandione, dinitroaniline, pyrethrin, and thiocarbamate were analyzed using this method. Analysis of these samples showed that addition of acid to the neat sample did not appreciably increase the protonated analyte signal nor the total ion current for any of the samples analyzed. This observation together with the extremely low pKa values of these pesticides, calculated by SPARC, indicates that the protonated analytes are formed in the gas rather than in the condensed phase. Sodium and ammonium ions were added to these pesticides but in no case was the total ion current increased over that from the neat sample. Solvent studies showed that 50/50 mixtures of methanol/water and acetonitrile/water are both suitable solvent systems but that a methanol fraction of 30% appears to be ideal for some of the pesticides studied. Evidence of radical cation formation was observed when pure acetonitrile was used. It was demonstrated, by spiking 5 carbamate pesticides into Yellowstone River water, that ESI/MS by the direct injection method is a potential candidate as a rapid screening method for pesticides in natural waters.

  4. Atomistic Modeling of the Hypervelocity Impact of Electrosprayed Nanodroplets

    NASA Astrophysics Data System (ADS)

    Saiz Poyatos, Fernan

    Uniform beams of nanodroplets can be electrosprayed in a vacuum by applying strong electric fields at the tip of an emitter fed with an ionic liquid. These projectiles can be electrostatically accelerated up to velocities of several kilometers per second, and directed towards the surface of a crystalline solid to produce a hypervelocity impact. The phenomenology of these nanodroplet impacts is diverse: for example, it has been observed that the associated sputtering yield is of order one; and that at high enough projectile velocity the bombardment amorphizes the surface of silicon. However there is no detailed understanding of the physical mechanisms behind these observations. The goal of this doctoral research is to correct this situation. Molecular Dynamics (MD) are employed to simulate a number of nanodroplet impacts, which in turn yields accurate thermodynamic and structural information of the target. This information reveals that the amorphization is caused by the fast cooling of the liquid layer produced on the impact face, and the sputtering is caused by the evaporation of the melt. A collection of sensitivity analysis gauges how both phenomena are influenced by the silicon interaction potential, and the projectile's velocity, size, angle of incidence, dose, and composition. The projectile's velocity plays the most significant role. The thickness of the melt becomes comparable to the droplet's diameter at around 3 km/s, as reported by the experiments. Sputtering is first observed approximately at 3 km/s in agreement with the evaporation mechanism. The projectile's composition plays a major role. By using droplets with molecules of larger size and weight, the temperatures and sputtering near the impact interface increase considerably.

  5. Multistage Reactive Transmission-Mode Desorption Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Peters, Kevin C.; Comi, Troy J.; Perry, Richard H.

    2015-09-01

    Elucidating reaction mechanisms is important for advancing many areas of science such as catalyst development. It is often difficult to probe fast reactions at ambient conditions with high temporal resolution. In addition, systems involving reagents that cross-react require analytical methods that can minimize interaction time and specify their order of introduction into the reacting system. Here, we explore the utility of transmission mode desorption electrospray ionization (TM-DESI) for reaction monitoring by directing a microdroplet spray towards a series of meshes with micrometer-sized openings coated with reagents, an approach we call multistage reactive TM-DESI (TM n -DESI, where n refers to the number of meshes; n = 2 in this report). Various stages of the reaction are initiated at each mesh surface, generating intermediates and products in microdroplet reaction vessels traveling towards the mass spectrometer. Using this method, we investigated the reactivity of iron porphyrin catalytic hydroxylation of propranolol and other substrates. Our experimental results indicate that TM n -DESI provides the ability to spatially separate reagents and control their order of introduction into the reacting system, thereby minimizing unwanted reactions that lead to catalyst deactivation and degradation products. In addition, comparison with DESI-MS analyses (the Zare and Latour laboratories published results suggesting accessible reaction times <1 ms) of the reduction of dichlorophenolindophenol by L-ascorbic acid suggest that TM 1 -DESI can access reaction times less than 1 ms. Multiple meshes allow sequential stages of desorption/ionization per MS scan, increasing the number of analytes and reactions that can be characterized in a single experiment.

  6. Infrared Laser Ablation Sample Transfer for MALDI and Electrospray

    NASA Astrophysics Data System (ADS)

    Park, Sung-Gun; Murray, Kermit King

    2011-08-01

    We have used an infrared laser to ablate materials under ambient conditions that were captured in solvent droplets. The droplets were either deposited on a MALDI target for off-line analysis by MALDI time-of-flight mass spectrometry or flow-injected into a nanoelectrospray source of an ion trap mass spectrometer. An infrared optical parametric oscillator (OPO) laser system at 2.94 μm wavelength and approximately 1 mJ pulse energy was focused onto samples for ablation at atmospheric pressure. The ablated material was captured in a solvent droplet 1-2 mm in diameter that was suspended from a silica capillary a few millimeters above the sample target. Once the sample was transferred to the droplet by ablation, the droplet was deposited on a MALDI target. A saturated matrix solution was added to the deposited sample, or in some cases, the suspended capture droplet contained the matrix. Peptide and protein standards were used to assess the effects of the number of IR laser ablation shots, sample to droplet distance, capture droplet size, droplet solvent, and laser pulse energy. Droplet collected samples were also injected into a nanoelectrospray source of an ion trap mass spectrometer with a 500 nL injection loop. It is estimated that pmol quantities of material were transferred to the droplet with an efficiency of approximately 1%. The direct analysis of biological fluids for off-line MALDI and electrospray was demonstrated with blood, milk, and egg. The implications of this IR ablation sample transfer approach for ambient imaging are discussed.

  7. PSD analysis of optical QSO light curves

    NASA Astrophysics Data System (ADS)

    Simm, Torben; Salvato, M.; Saglia, R.; Ponti, G.; Lanzuisi, G.; Trakhtenbrot, B.; Nandra, K.; Bender, R.

    2016-08-01

    One of the elementary properties of quasar activity is continuous variability in the UV/optical bands. The power spectral density (PSD) potentially contains information about the underlying processes connected to variability. We applied a novel method based on continuous-time autoregressive moving average (CARMA) models (Kelly et al. 2014) to derive the PSD even for irregularly sampled light curves. Using a sample of ~100 X-ray selected non-local QSOs from the XMM-COSMOS catalog and optical light curves provided by the Pan-STARRS1 MDF survey we find that the PSD resembles a broken power-law with a high-frequency slope significantly steeper than observed in X-ray studies. The PSD normalization is observed to scale inversely with bolometric luminosity and Eddington ratio, whereas there is no correlation between the characteristic bend timescale and black hole mass. We find a weak tendency for QSOs with higher black hole mass to have steeper high-frequency PSD slopes. In an ongoing work we extend these studies employing a sample of ~700 variable broad-line QSOs with high-quality black hole mass estimates and well-sampled light curves from the SDSS-RM project.

  8. Elastomeric Microchip Electrospray Emitter for Stable Cone-Jet Mode Operation in the Nanoflow Regime.

    SciTech Connect

    Kelly, Ryan T.; Tang, Keqi; Irimia, Daniel; Toner, Mehmet; Smith, Richard D.

    2008-05-15

    Despite widespread interest in applying lab-on-a-chip technologies to mass spectrometry (MS)-based analyses, the coupling of microfluidics to electrospray ionization (ESI)-MS remains challenging. We report a robust, integrated poly(dimethylsiloxane) microchip interface for ESI-MS using simple and widely accessible microfabrication procedures. The interface uses an auxiliary channel to provide electrical contact in the Taylor cone of the electrospray without sample loss or dilution. The electric field at the channel terminus is enhanced by two vertical cuts that cause the interface to taper to a line rather than to a point, and the formation of small Taylor cones at the channel exit ensures sub-nL post-column dead volumes. While comparable ESI-MS sensitivities were achieved using both microchip and conventional fused silica capillary emitters, stable cone-jet mode electrospray could be established over a far broader range of flow rates (from 50–1000 nL/min) and applied potentials using the microchip emitters. This special feature of the microchip emitter should minimize the fine tuning required for electrospray optimization and make the stable electrospray more resistant to external perturbations.

  9. Improved electrospray ionization interface for capillary zone electrophoresis-mass spectrometry

    SciTech Connect

    Smith, R.D.; Barinaga, C.J.; Udseth, H.R.

    1988-09-15

    A new electrospray ionization interface for capillary zone electrophoresis-mass spectrometry (CZE-MS) is described. The interface uses a sheath flow of liquid to make the electrical contact at the CZE terminus, thus defining both the CZE and electrospray field gradients. This allows the composition of the electrosprayed liquid to be controlled independently of the CZE buffer, providing operation with buffers that could not be used previously (e.g., aqueous and high ionic strength buffers). The interface operation is independent of CZE flow rate; CZE capillaries are easily replaced and require no additional preparation. Since the electrospray occurs directly from the CZE capillary terminus, additional mixing volumes and metal surfaces are avoided and electrophoretic separation efficiency appears unperturbed. The dead volume associated with the electrospray interface is < 10 nL, corresponding to < 0.1 s for typical flow rates of the sheath electrode liquid. CZE-MS separations for mixtures of quaternary phosphonium salts and for epinephrine and related amines are demonstrated. Operation is demonstrated with high surfactant concentrations, as required for capillary electrokinetic chromatography. The extension to other capillary electrophoresis methods, such as isotachophoresis and isoelectric focusing, appears feasible.

  10. Electrospray synthesis and properties of hierarchically structured PLGA TIPS microspheres for use as controlled release technologies.

    PubMed

    Malik, Salman A; Ng, Wing H; Bowen, James; Tang, Justin; Gomez, Alessandro; Kenyon, Anthony J; Day, Richard M

    2016-04-01

    Microsphere-based controlled release technologies have been utilized for the long-term delivery of proteins, peptides and antibiotics, although their synthesis poses substantial challenges owing to formulation complexities, lack of scalability, and cost. To address these shortcomings, we used the electrospray process as a reproducible, synthesis technique to manufacture highly porous (>94%) microspheres while maintaining control over particle structure and size. Here we report a successful formulation recipe used to generate spherical poly(lactic-co-glycolic) acid (PLGA) microspheres using the electrospray (ES) coupled with a novel thermally induced phase separation (TIPS) process with a tailored Liquid Nitrogen (LN2) collection scheme. We show how size, shape and porosity of resulting microspheres can be controlled by judiciously varying electrospray processing parameters and we demonstrate examples in which the particle size (and porosity) affect release kinetics. The effect of electrospray treatment on the particles and their physicochemical properties are characterized by scanning electron microscopy, confocal Raman microscopy, thermogravimetric analysis and mercury intrusion porosimetry. The microspheres manufactured here have successfully demonstrated long-term delivery (i.e. 1week) of an active agent, enabling sustained release of a dye with minimal physical degradation and have verified the potential of scalable electrospray technologies for an innovative TIPS-based microsphere production protocol.

  11. Determination of benzothiazole and benzotriazole derivates in tire and clothing textile samples by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger

    2013-09-13

    A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance.

  12. Optical Phase Curves of Kepler Exoplanets

    NASA Astrophysics Data System (ADS)

    Esteves, Lisa J.; De Mooij, Ernst J. W.; Jayawardhana, Ray

    2013-07-01

    We conducted a comprehensive search for optical phase variations of all close-in (a/R sstarf < 10) planet candidates in 15 quarters of Kepler space telescope data. After correcting for systematics, we found eight systems that show secondary eclipses as well as phase variations. Of these, five (Kepler-5, Kepler-6, Kepler-8, KOI-64, and KOI-2133) are new and three (TrES-2, HAT-P-7, and KOI-13) have published phase curves, albeit with many fewer observations. We model the full phase curve of each planet candidate, including the primary and secondary transits, and derive their albedos, dayside and nightside temperatures, ellipsoidal variations, and Doppler beaming. We find that KOI-64 and KOI-2133 have nightside temperatures well above their equilibrium values (while KOI-2133 also has an albedo, >1), so we conclude that they are likely to be self-luminous objects rather than planets. The other six candidates have characteristics consistent with their being planets with low geometric albedos (<0.3). For TrES-2 and KOI-13, the Kepler bandpass appears to probe atmospheric layers hotter than the planet's equilibrium temperature. For KOI-13, we detect a never-before-seen third cosine harmonic with an amplitude of 6.7 ± 0.3 ppm and a phase shift of -1.1 ± 0.1 rad in the phase curve residual, possibly due to its spin-orbit misalignment. We report derived planetary parameters for all six planets, including masses from ellipsoidal variations and Doppler beaming, and compare our results to published values when available. Our results nearly double the number of Kepler exoplanets with measured phase curve variations, thus providing valuable constraints on the properties of hot Jupiters.

  13. OPTICAL PHASE CURVES OF KEPLER EXOPLANETS

    SciTech Connect

    Esteves, Lisa J.; De Mooij, Ernst J. W.; Jayawardhana, Ray E-mail: demooij@astro.utoronto.ca

    2013-07-20

    We conducted a comprehensive search for optical phase variations of all close-in (a/R{sub *} < 10) planet candidates in 15 quarters of Kepler space telescope data. After correcting for systematics, we found eight systems that show secondary eclipses as well as phase variations. Of these, five (Kepler-5, Kepler-6, Kepler-8, KOI-64, and KOI-2133) are new and three (TrES-2, HAT-P-7, and KOI-13) have published phase curves, albeit with many fewer observations. We model the full phase curve of each planet candidate, including the primary and secondary transits, and derive their albedos, dayside and nightside temperatures, ellipsoidal variations, and Doppler beaming. We find that KOI-64 and KOI-2133 have nightside temperatures well above their equilibrium values (while KOI-2133 also has an albedo, >1), so we conclude that they are likely to be self-luminous objects rather than planets. The other six candidates have characteristics consistent with their being planets with low geometric albedos (<0.3). For TrES-2 and KOI-13, the Kepler bandpass appears to probe atmospheric layers hotter than the planet's equilibrium temperature. For KOI-13, we detect a never-before-seen third cosine harmonic with an amplitude of 6.7 {+-} 0.3 ppm and a phase shift of -1.1 {+-} 0.1 rad in the phase curve residual, possibly due to its spin-orbit misalignment. We report derived planetary parameters for all six planets, including masses from ellipsoidal variations and Doppler beaming, and compare our results to published values when available. Our results nearly double the number of Kepler exoplanets with measured phase curve variations, thus providing valuable constraints on the properties of hot Jupiters.

  14. Accurate quantification of creatinine in serum by coupling a measurement standard to extractive electrospray ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Huang, Keke; Li, Ming; Li, Hongmei; Li, Mengwan; Jiang, You; Fang, Xiang

    2016-01-01

    Ambient ionization (AI) techniques have been widely used in chemistry, medicine, material science, environmental science, forensic science. AI takes advantage of direct desorption/ionization of chemicals in raw samples under ambient environmental conditions with minimal or no sample preparation. However, its quantitative accuracy is restricted by matrix effects during the ionization process. To improve the quantitative accuracy of AI, a matrix reference material, which is a particular form of measurement standard, was coupled to an AI technique in this study. Consequently the analyte concentration in a complex matrix can be easily quantified with high accuracy. As a demonstration, this novel method was applied for the accurate quantification of creatinine in serum by using extractive electrospray ionization (EESI) mass spectrometry. Over the concentration range investigated (0.166 ~ 1.617 μg/mL), a calibration curve was obtained with a satisfactory linearity (R2 = 0.994), and acceptable relative standard deviations (RSD) of 4.6 ~ 8.0% (n = 6). Finally, the creatinine concentration value of a serum sample was determined to be 36.18 ± 1.08 μg/mL, which is in excellent agreement with the certified value of 35.16 ± 0.39 μg/mL.

  15. Rapid determination of three anticoagulant rodenticides in whole blood by liquid chromatography coupled with electrospray ionization mass spectrometry.

    PubMed

    Jin, Mi-Cong; Chen, Xiao-Hong

    2006-01-01

    A rapid, sensitive and selective method for the simultaneous determination of bromadiolone, flocoumafen and brodifacoum in whole blood using warfarin as internal standard (IS) by high-performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC/ESI-MS) has been developed and validated. The target compounds were extracted from the whole blood with ethyl acetate and separated on an XDB C18 column (150 mm x 2.1 mm i.d. x 5 microm) by using a mobile phase consisting of 0.2% acetic acid/methanol (12/88, v/v) at a constant flow rate of 0.50 mL/min. The analytes were detected using negative ESI-MS in the selected ion monitoring (SIM) mode. The molecular ions [M-H]- of m/z 527, 541,523 and 307 were selected for the quantification for bromadiolone, flocoumafen, brodifacoum and the IS, respectively. The calibration curves were linear (r2 > 0.995) in the concentration range of 0.50-100.00 ng/mL. The method showed a satisfactory sensitivity (0.05-0.5 ng/mL using 200 microL blood), precision (RSD < 11.9%), accuracy (recovery: 82.0-96.1%) and selectivity. This method was successfully applied to the determination of the analytes for the diagnoses of poisoned human beings and animals.

  16. Simultaneous quantitative analysis of dextromethorphan, dextrorphan and chlorphenamine in human plasma by liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Ding, Ying; Huang, Kai; Chen, Lan; Yang, Jie; Xu, Wen-Yan; Xu, Xue-Jiao; Duan, Ru; Zhang, Jing; He, Qing

    2014-03-01

    A sensitive and accurate HPLC-MS/MS method was developed for the simultaneous determination of dextromethorphan, dextrorphan and chlorphenamine in human plasma. Three analytes were extracted from plasma by liquid-liquid extraction using ethyl acetate and separated on a Kromasil 60-5CN column (3 µm, 2.1 × 150 mm) with mobile phase of acetonitrile-water (containing 0.1% formic acid; 50:50, v/v) at a flow rate of 0.2 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The calibration curve was linear over the range of 0.01-5 ng/mL for dextromethorphan, 0.02-5 ng/mL for dextrorphan and 0.025-20 ng/mL for chlorphenamine. The lower limits of quantification for dextromethorphan, dextrorphan and chlorphenamine were 0.01, 0.02 and 0.025 ng/mL, respectively. The intra- and inter-day precisions were within 11% and accuracies were in the range of 92.9-102.5%. All analytes were proved to be stable during sample storage, preparation and analytic procedures. This method was first applied to the pharmacokinetic study in healthy Chinese volunteers after a single oral dose of the formulation containing dextromethorphan hydrobromide (18 mg) and chlorpheniramine malaeate (8 mg).

  17. Determination of error measurement by means of the basic magnetization curve

    NASA Astrophysics Data System (ADS)

    Lankin, M. V.; Lankin, A. M.

    2016-04-01

    The article describes the implementation of the methodology for determining the error search by means of the basic magnetization curve of electric cutting machines. The basic magnetization curve of the integrated operation of the electric characteristic allows one to define a fault type. In the process of measurement the definition of error calculation of the basic magnetization curve plays a major role as in accuracies of a particular characteristic can have a deleterious effect.

  18. Specific detection and quantification of palmitoyl-stearoyl-phosphatidylserine in human blood using normal-phase liquid chromatography coupled with electrospray mass spectrometry.

    PubMed

    Hvattum, E; Larsen, A; Uran, S; Michelsen, P M; Skotland, T

    1998-09-25

    A narrow-bore normal-phase high-performance liquid chromatography (HPLC) method was developed for separation of phospholipid classes using an HPLC diol column and a gradient of chloroform and methanol with 0.2% formic acid titrated to pH 5.3 with ammonia. The HPLC system was coupled on-line with an electrospray mass spectrometry (ES-MS) or electrospray tandem mass spectrometry (ES-MS-MS) system and the separation of several major phospholipid classes was shown. The molecular species of some phospholipid classes in human blood were qualitatively determined. A method was further developed for specific determination of a molecular species from phosphatidylserine, palmitoyl-stearoyl-phosphatidylserine (PSPS), in human blood using HPLC-ES-MS. The analyses were performed by single ion monitoring of the [M-H]- molecular ions of PSPS and an internal standard, dipalmitoyl-phosphatidylserine. The limit of quantification of the method was 1.2 ng of PSPS. The calibration curve ranged from 0.12 to 5.81 microg/ml of PSPS dissolved in the mobile phase. The curve was fitted to a second-order polynomial equation and found to be highly reproducible. Analysis of control samples was found to be reproducible with a between-series precision below 9.2% R.S.D. The amount of endogenous PSPS in human blood was determined in 13 subjects and found to range from 1.73 to 3.09 microg/ml. The identity of endogenous PSPS was confirmed by HPLC-ES-MS-MS.

  19. Fragmentation pathways and structural characterization of 14 nerve agent compounds by electrospray ionization tandem mass spectrometry.

    PubMed

    Housman, Kathleen J; Swift, Austin T; Oyler, Jonathan M

    2015-03-01

    Organophosphate nerve agents (OPNAs) are some of the most widely used and proliferated chemical warfare agents. As evidenced by recent events in Syria, these compounds remain a serious military and terrorist threat to human health because of their toxicity and the ease with which they can be used, produced and stored. There are over 2,000 known, scheduled compounds derived from common parent structures with many more possible. To address medical, forensic, attribution, remediation and other requirements, laboratory systems have been established to provide the capability to analyze 'unknown' samples for the presence of these compounds. Liquid chromatography/mass spectrometric methods have been validated and are routinely used in the analysis of samples for a very limited number of these compounds, but limited data exist characterizing the electrospray ionization (ESI) and mass spectrometric fragmentation pathways of the compound families. This report describes results from direct infusion ESI/MS, ESI/MS(2) and ESI/MS(3) analysis of 14 G and V agents, the major OPNA families, using an AB Sciex 4000 QTrap. Using a range of conditions, spectra were acquired and characteristic fragments identified. The results demonstrated that the reproducible and predictable fragmentation of these compounds by ESI/MS, ESI/MS(2) and ESI/MS(3) can be used to describe systematic fragmentation pathways specific to compound structural class. These fragmentation pathways, in turn, may be useful as a predictive tool in the analysis of samples by screening and confirmatory laboratories to identify related compounds for which authentic standards are not readily available.

  20. Online Investigation of Aqueous-Phase Electrochemical Reactions by Desorption Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Lu, Mei; Liu, Yong; Helmy, Roy; Martin, Gary E.; Dewald, Howard D.; Chen, Hao

    2015-08-01

    Electrochemistry (EC) combined with mass spectrometry (MS) is a powerful tool for elucidation of electrochemical reaction mechanisms. However, direct online analysis of electrochemical reaction in aqueous phase was rarely explored. This paper presents the online investigation of several electrochemical reactions with biological relevance in the aqueous phase, such as nitrosothiol reduction, carbohydrate oxidation, and carbamazepine oxidation using desorption electrospray ionization mass spectrometry (DESI-MS). It was found that electroreduction of nitrosothiols [e.g., nitrosylated insulin B (13-23)] leads to free thiols by loss of NO, as confirmed by online MS analysis for the first time. The characteristic mass shift of 29 Da and the reduced intensity provide a quick way to identify nitrosylated species. Equally importantly, upon collision-induced dissociation (CID), the reduced peptide ion produces more fragment ions than its nitrosylated precursor ion (presumably the backbone fragmentation cannot compete with the facile NO loss for the precursor ion), thus facilitating peptide sequencing. In the case of saccharide oxidation, it was found that glucose undergoes electro-oxidation to produce gluconic acid at alkaline pH, but not at neutral and acidic pHs. Such a pH-dependent electrochemical behavior was also observed for disaccharides such as maltose and cellobiose. Upon electrochemical oxidation, carbamazepine was found to undergo ring contraction and amide bond cleavage, which parallels the oxidative metabolism observed for this drug in leucocytes. The mechanistic information of these redox reactions revealed by EC/DESI-MS would be of value in nitroso-proteome research and carbohydrate/drug metabolic studies.

  1. Online Investigation of Aqueous-Phase Electrochemical Reactions by Desorption Electrospray Ionization Mass Spectrometry.

    PubMed

    Lu, Mei; Liu, Yong; Helmy, Roy; Martin, Gary E; Dewald, Howard D; Chen, Hao

    2015-10-01

    Electrochemistry (EC) combined with mass spectrometry (MS) is a powerful tool for elucidation of electrochemical reaction mechanisms. However, direct online analysis of electrochemical reaction in aqueous phase was rarely explored. This paper presents the online investigation of several electrochemical reactions with biological relevance in the aqueous phase, such as nitrosothiol reduction, carbohydrate oxidation, and carbamazepine oxidation using desorption electrospray ionization mass spectrometry (DESI-MS). It was found that electroreduction of nitrosothiols [e.g., nitrosylated insulin B (13-23)] leads to free thiols by loss of NO, as confirmed by online MS analysis for the first time. The characteristic mass shift of 29 Da and the reduced intensity provide a quick way to identify nitrosylated species. Equally importantly, upon collision-induced dissociation (CID), the reduced peptide ion produces more fragment ions than its nitrosylated precursor ion (presumably the backbone fragmentation cannot compete with the facile NO loss for the precursor ion), thus facilitating peptide sequencing. In the case of saccharide oxidation, it was found that glucose undergoes electro-oxidation to produce gluconic acid at alkaline pH, but not at neutral and acidic pHs. Such a pH-dependent electrochemical behavior was also observed for disaccharides such as maltose and cellobiose. Upon electrochemical oxidation, carbamazepine was found to undergo ring contraction and amide bond cleavage, which parallels the oxidative metabolism observed for this drug in leucocytes. The mechanistic information of these redox reactions revealed by EC/DESI-MS would be of value in nitroso-proteome research and carbohydrate/drug metabolic studies.

  2. Analysis of solvent dyes in refined petroleum products by electrospray ionization mass spectrometry

    USGS Publications Warehouse

    Rostad, C.E.

    2010-01-01

    Solvent dyes are used to color refined petroleum products to enable differentiation between gasoline, diesel, and jet fuels. Analysis for these dyes in the hydrocarbon product is difficult due to their very low concentrations in such a complex matrix. Flow injection analysis/electrospray ionization/mass spectrometry in both negative and positive mode was used to optimize ionization of ten typical solvent dyes. Samples of hydrocarbon product were analyzed under similar conditions. Positive electrospray ionization produced very complex spectra, which were not suitably specific for targeting only the dyes. Negative electrospray ionization produced simple spectra because aliphatic and aromatic moieties were not ionized. This enabled screening for a target dye in samples of hydrocarbon product from a spill.

  3. Titanium dioxide thin film deposited on flexible substrate by multi-jet electrospraying

    NASA Astrophysics Data System (ADS)

    Ni, Daihong; Yi, Wuming; Cao, Zhoubin; Gu, Wenhua

    2015-10-01

    Titanium dioxide thin film plays an important role in thin film solar cells, and has promising future in everyday applications including air cleaning and self-cleaning glass. With the concepts of flexible solar cells and wearable devices being more and more popular, there is increasing interest to coat titanium dioxide thin films on flexible substrates, such as aluminum foils. Many methods have been used to fabricate titanium dioxide thin films, such as dip-coating, spin coating, aerosol spray, plasma-assisted coating, electrospraying, and so on. Among them, electrospraying is especially suitable for thin film deposition on flexible substrates. This work reports fabrication of dense and uniform titanium dioxide thin films on glass as well as flexible aluminum foil using multi-jet electrospraying technique.

  4. On-line micellar electrokinetic chromatography-electrospray ionization mass spectrometry using anodically migrating micelles

    SciTech Connect

    Yang, L.; Harrata, A.K.; Lee, C.S. |

    1997-05-15

    On-line micellar electrokinetic chromatography (MEKC)-electrospray ionization mass spectrometry (ESIMS) is demonstrated for the analysis of chlorotriazine herbicides and barbiturates. In this study, the micellar velocity is directly manipulated by the adjustment of electroosmosis rather than the electrophoretic velocity of the micelle. The electroosmotic flow is adjusted against the electrophoretic velocity of the micelle by changing the solution pH in MEKC. The elimination of MEKC surfactant introduction into ESIMS is achieved with an anodically migrating micelle, moving away from the electrospray interface. The effects of moving surfactant boundary in the MEKC capillary on separation efficiency and resolution of triazine herbicides and barbiturates are investigated. The mass detection of herbicides and barbiturates sequentially eluted from the MEKC capillary is acquired using the positive and negative electrospray modes, respectively. 30 refs., 8 figs., 3 tabs.

  5. Studies on the controlled morphology and wettability of PS surfaces by electrospinning or electrospraying.

    NASA Astrophysics Data System (ADS)

    Zheng, Jianfen; He, Aihua; Han, Charles

    2007-03-01

    Electrospinning/electrospraying is a simple and effective way to fabricate various polymer surfaces such as beads, fibers and other shapes in the range of micro- to nanometer. Various surface morphologies have been produced by electrospinning or electrospraying: beads with different sizes and shapes, bead-on-string structure with different aspect ratios and fibers with different diameters and shapes. Physical properties of the PS solutions such as viscosity, surface tension and conductivity greatly influence the electrospun or electrosprayed PS morphology. The wettability of a solid surface is greatly influenced by its surface morphology: A spin-coated PS membrane has a water contact angle of 97^o, while electrospun PS membranes have water contact angles around 150^o. The most hydrophobic membrane has a water CA of 159.5^o.

  6. Classification of Gunshot Residue Using Laser Electrospray Mass Spectrometry and Offline Multivariate Statistical Analysis.

    PubMed

    Perez, Johnny J; Watson, David A; Levis, Robert J

    2016-12-06

    Nonresonant laser vaporization combined with high-resolution electrospray time-of-flight mass spectrometry enables analysis of a casing after discharge of a firearm revealing organic signature molecules including methyl centralite (MC), diphenylamine (DPA), N-nitrosodiphenylamine (N-NO-DPA), 4-nitrodiphenylamine (4-NDPA), a DPA adduct, and multiple unidentified features not observed in previous mass spectral measurements. Collision-induced dissociation measurements of unknown GSR signature ions reveals inorganic barium and derivatives BaOH, BaOHCH3, BaCH3COO remaining from the primer. Both hydrophilic and hydrophobic signatures are detected using water-methanol electrospray solution. Offline principal component analysis and discrimination of the laser electrospray mass spectral (LEMS) measurements resulted in perfect classification of the gun shot residue with respect to the manufacturer. Principal component analysis of recycled and reloaded casings resulted in classification of the penultimate manufacturer with an accuracy of 89%.

  7. Study on the inclusion complexes of cyclodextrin and sulphonated azo dyes by electrospray ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Zhang, Huarong; Chen, Gang; Wang, Ling; Ding, Lan; Tian, Yuan; Jin, Weiqun; Zhang, Hanqi

    2006-05-01

    The inclusion complexes of [alpha]-, [beta]-cyclodextrin ([alpha]-, [beta]-CD) and sulphonated azo dyes ligands (Orange II, Ponceau SX, Allura red AC and Tartrazine) were studied by electrospray ionization mass spectrometry (ESI-MS) and the dissociation constants (KD) of the inclusion complexes were determined. A new method to obtain the dissociation constants of CD-ligand inclusion complexes without curve fitting was developed. Once the total concentrations of CD and ligand have been known, KD can be calculated from the sum peak intensities of free CD and inclusion complex and the number of binding site can be obtained from the mass spectrum. Ponceau SX, Allura red AC and Tartrazine binding to [alpha]-CD form 1:1 inclusion complexes with KD values of 1.33 × 10-5 mol L-1, 4.85 × 10-6 mol L-1 and 7.47 × 10-5 mol L-1, respectively. The obtained KD values of the inclusion complexes of above-mentioned three sulphonated azo dyes ligands binding to [beta]-CD in turn are 3.93 × 10-6 mol L-1, 6.50 × 10-6 mol L-1 and 1.12 × 10-4 mol L-1, respectively. The 1:1 and 1:2 inclusion complexes are found in the systems of CD and Orange II. KD,1 and KD,2 of [alpha]-CD and Orange II inclusion complexes are 4.05 × 10-4 mol L-1 and 4.60 × 10-7 (mol L-1)2, respectively. 3.94 × 10-5 mol L-1 and 1.72 × 10-7 (mol L-1)2 are the KD,1 and KD,2 of [beta]-CD and Orange II inclusion complexes, respectively. The competition experiments were performed to validate the results obtained by one ligand. According to the proposed method, the KD values of inclusion complexes regardless of any stoichiometric relation of host and guest can be obtained.

  8. Relative Locality in Curved Spacetime

    NASA Astrophysics Data System (ADS)

    Kowalski-Glikman, Jerzy; Rosati, Giacomo

    2013-07-01

    In this paper we construct the action describing dynamics of the particle moving in curved spacetime, with a nontrivial momentum space geometry. Curved momentum space is the core feature of theories where relative locality effects are present. So far aspects of nonlinearities in momentum space have been studied only for flat or constantly expanding (de Sitter) spacetimes, relying on their maximally symmetric nature. The extension of curved momentum space frameworks to arbitrary spacetime geometries could be relevant for the opportunities to test Planck-scale curvature/deformation of particles momentum space. As a first example of this construction we describe the particle with κ-Poincaré momentum space on a circular orbit in Schwarzschild spacetime, where the contributes of momentum space curvature turn out to be negligible. The analysis of this problem relies crucially on the solution of the soccer ball problem.

  9. Phase nucleation in curved space

    NASA Astrophysics Data System (ADS)

    Gómez, Leopoldo; García, Nicolás; Vitelli, Vincenzo; Lorenzana, José; Daniel, Vega

    Nucleation and growth is the dominant relaxation mechanism driving first-order phase transitions. In two-dimensional flat systems, nucleation has been applied to a wide range of problems in physics, chemistry and biology. Here we study nucleation and growth of two-dimensional phases lying on curved surfaces and show that curvature modifies both critical sizes of nuclei and paths towards the equilibrium phase. In curved space, nucleation and growth becomes inherently inhomogeneous and critical nuclei form faster on regions of positive Gaussian curvature. Substrates of varying shape display complex energy landscapes with several geometry-induced local minima, where initially propagating nuclei become stabilized and trapped by the underlying curvature (Gómez, L. R. et al. Phase nucleation in curved space. Nat. Commun. 6:6856 doi: 10.1038/ncomms7856 (2015).).

  10. Supply curves of conserved energy

    NASA Astrophysics Data System (ADS)

    Meier, A. K.

    1982-05-01

    Supply curves of conserved energy provide an accounting framework that expresses the potential for energy conservation. The economic worthiness of a conservation measure is expressed in terms of the cost of conserved energy, and a measure is considered economical when the cost of conserved energy is less than the price of the energy it replaces. A supply curve of conserved energy is independent of energy prices; however, the economical reserves of conserved energy will depend on energy prices. Double-counting of energy savings and error propagation are common problems when estimating conservation potentials, but supply curves minimize these difficulties and make their consequences predictable. The sensitivity of the cost of conserved energy is examined, as are variations in the optimal investment strategy in response to changes in inputs. Guidelines are presented for predicting the consequences of such changes.

  11. Curve Fit Technique for a Smooth Curve Using Gaussian Sections.

    DTIC Science & Technology

    1983-08-01

    curve-fitting. Furthermore, the algorithm that does the fitting is simple enough to be used on a programmable calculator . 8 -I.F , A X i 4. Y-14 .4. - -* F.J OR;r IF 17 r*~~ , ac ~J ’a vt. . S ~ :.. *~All, a-4k .16’.- a1 1, t

  12. Fischer Indole Synthesis in the Gas Phase, the Solution Phase, and at the Electrospray Droplet Interface

    NASA Astrophysics Data System (ADS)

    Bain, Ryan M.; Ayrton, Stephen T.; Cooks, R. Graham

    2017-02-01

    Previous reports have shown that reactions occurring in the microdroplets formed during electrospray ionization can, under the right conditions, exhibit significantly greater rates than the corresponding bulk solution-phase reactions. The observed acceleration under electrospray ionization could result from a solution-phase, a gas-phase, or an interfacial reaction. This study shows that a gas-phase ion/molecule (or ion/ion) reaction is not responsible for the observed rate enhancement in the particular case of the Fischer indole synthesis. The results show that the accelerated reaction proceeds in the microdroplets, and evidence is provided that an interfacial process is involved.

  13. Electrospray/Ion Trap Mass Spectrometry for the Detection and Identification of Organisms

    SciTech Connect

    McLuckey, Scott A.; Stephenson, James L., Jr.

    1997-12-31

    Current electrospray ion trap methodology for rapid mixture analysis of proteins used for the identification of microorganisms is described. Development of ion/ion reaction techniques (e.g. reactions of multiply-charged protein cations with singly-charged anions) from both a fundamental and practical approach are presented, detailing the necessary steps and considerations involved in complex mixture analysis. Data describing the reduction of the initial charge states of electrospray ions to arbitrarily low values, the utility of ion/ion reactions for mixture separation on the millisecond time scale, and effects of excess singly-charged reactants on detection and storage efficiency are illustrated.

  14. Rapid differentiation of refined fuels using negative electrospray ionization/mass spectrometry

    USGS Publications Warehouse

    Rostad, C.E.; Hostettler, F.D.

    2005-01-01

    An application of electrospray ionization/mass spectrometry for identification of various commercially refined fuels using the unique signature of polar components, was investigated. The samples were analyzed by mass spectrometry using negative electrospray on an Agilent Series 1100 liquid chromatograph/mass spectrometer. These analysis were applied to hydrocarbon samples from a large, long-term fuel spill which were taken from the subsurface and different extent of biodegradation or weathering. The technique provided rapid identification of hydrocarbons released into the environment because these polar compounds are unique in different fuels.

  15. Active particles on curved surfaces

    NASA Astrophysics Data System (ADS)

    Fily, Yaouen; Baskaran, Aparna; Hagan, Michael

    Active systems have proved to be very sensitive to the geometry of their environment. This is often achieved by spending significant time at the boundary, probing its shape by gliding along it. I will discuss coarse graining the microscopic dynamics of self-propelled particles on a general curved surface to predict the way the density profile on the surface depends on its geometry. Beyond confined active particles, this formalism is a natural starting point to study objects that cannot leave the boundary at all, such as cells crawling on a curved substrate, animals running on uneven ground, or active colloids trapped at an interface.

  16. Shock detachment from curved wedges

    NASA Astrophysics Data System (ADS)

    Mölder, S.

    2017-03-01

    Curved shock theory is used to show that the flow behind attached shocks on doubly curved wedges can have either positive or negative post-shock pressure gradients depending on the freestream Mach number, the wedge angle and the two wedge curvatures. Given enough wedge length, the flow near the leading edge can choke to force the shock to detach from the wedge. This local choking can preempt both the maximum deflection and the sonic criteria for shock detachment. Analytical predictions for detachment by local choking are supported by CFD results.

  17. Equine cortical bone exhibits rising R-curve fracture mechanics.

    PubMed

    Malik, C L; Stover, S M; Martin, R B; Gibeling, J C

    2003-02-01

    Previous studies of the fracture properties of cortical bone have suggested that the fracture toughness increases with crack length, which is indicative of rising R-curve behavior. Based on this indirect evidence and the similarity of bone to ceramic matrix composites, we hypothesized that bone would exhibit rising R-curve behavior in the transverse orientation and that the characteristics of the R-curves would be regionally dependent within the cortex due to variations in bone microstructure and toughening mechanisms. To test these hypotheses, we conducted R-curve experiments on specimens from equine third metacarpal bones using standard fracture mechanics testing methods. Compact type specimens from the dorsal and lateral regions in the middle of the diaphysis were oriented for crack propagation transverse to the longitudinal axis of the bone. The test results demonstrate that equine cortical bone exhibits rising R-curve behavior during transverse crack propagation as hypothesized. Statistical analyses of the crack growth initiation toughness, K0, the peak toughness, Kpeak, and the crack extension at peak toughness, deltaa, revealed significant regional differences in these characteristics. Specifically, the lateral cortex displayed higher crack growth initiation and peak toughnesses. The dorsal cortex exhibited greater crack extension at the peak of crack growth resistance. Scanning electron microscopy revealed osteon pullout on fracture surfaces from the dorsal cortex and but not in the lateral cortex. Taken together, the significant differences in R-curves and the SEM fractography indicate that the fracture mechanisms acting in equine cortical bone are regionally dependent.

  18. NEXT Performance Curve Analysis and Validation

    NASA Technical Reports Server (NTRS)

    Saripalli, Pratik; Cardiff, Eric; Englander, Jacob

    2016-01-01

    Performance curves of the NEXT thruster are highly important in determining the thruster's ability in performing towards mission-specific goals. New performance curves are proposed and examined here. The Evolutionary Mission Trajectory Generator (EMTG) is used to verify variations in mission solutions based on both available thruster curves and the new curves generated. Furthermore, variations in BOL and EOL curves are also examined. Mission design results shown here validate the use of EMTG and the new performance curves.

  19. A High Voltage Power Supply That Mitigates Current Reversals in Capillary Zone Electrophoresis-Electrospray Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Flaherty, Ryan J.; Sarver, Scott A.; Sun, Liangliang; Brownell, Greg A.; Go, David B.; Dovichi, Norman J.

    2017-02-01

    Capillary electrophoresis coupled with electrospray ionization typically employs two power supplies, one at each end of the capillary. One power supply is located at the proximal (injection) end of the capillary. The power supply located at the distal (detector) end of the capillary drives the electrospray. Electrophoresis is driven by the difference in potential between these power supplies. Separations that employ large capillary inner diameter, high conductivity background electrolyte, and high separation potentials generate higher current than that produced by the electrospray. Excess current flows through the electrospray power supply. Most power supplies are not designed to sink current, and the excess current will cause the electrospray voltage to deviate from its set point. We report a simple circuit to handle this excess current, allowing separations under a wide range of electrophoretic conditions.

  20. Distribution study of cisplatin in rat kidney and liver cancer tissues by using liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Bandu, Raju; Ahn, Hyun Soo; Lee, Joon Won; Kim, Yong Woo; Choi, Seon Hee; Kim, Hak Jin; Kim, Kwang Pyo

    2015-06-01

    A sensitive and rapid liquid chromatography positive ion electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method has been developed and validated for the quantitative determination and distribution of cisplatin (CP) in kidney and liver tissues after intravenous administration of drug to adult male Sprague Dawley rats. Oxaliplatin (OXP) was used as an internal standard. The tissue samples were homogenized and extracted using conventional liquid-liquid extraction method with phosphate buffer containing ethyl acetate and then subjected to LC-MS analysis. The chromatographic separation was achieved on an Agilent ZORBAX SB C-18 column (50 × 2.1 mm, 1.8 µm) using the mobile phase consisting of 0.1% formic acid in water (Solvent A) : methanol (Solvent B) (40 : 60; v/v) in an isocratic elution followed by detection with positive ion electrospray ionization tandem mass spectrometry using the transitions of m/z 301 > 265 for CP and m/z 398 > 310 for OXP in multiple reaction monitoring mode. The calibration curve was linear in the range of 5.0-7000 and 10.0-6000 ng/ml for kidney and liver tissue homogenates, respectively. The method revealed good performances in terms of within-batch, between-batch precision (1.31-5.70%) and accuracy (97.0-102.24%) for CP in both kidney and liver tissue homogenates including lower and upper limits of quantification. The recoveries from spiked control samples were >81.0% and >87.0 % for CP and OXP, respectively. Matrix effect was found to be negligible, and the stability data were within the acceptable limits. Further, the validated LC/ES-MS/MS method was successfully applied to investigate the distribution of CP in kidney and liver tissues after intravenous administration of CP to male Sprague Dawley rats. The results showed that the higher amount of CP was distributed in kidney followed by liver, which indicated that CP mainly accumulated in kidney tissues and renal excretion might be a primary and

  1. Glycomics expression analysis of sulfated glycosaminoglycans of human colorectal cancer tissues and non-neoplastic mucosa by electrospray ionization mass spectrometry

    PubMed Central

    Marolla, Ana Paula Cleto; Waisberg, Jaques; Saba, Gabriela Tognini; Waisberg, Daniel Reis; Margeotto, Fernando Beani; Pinhal, Maria Aparecida da Silva

    2015-01-01

    ABSTRACT Objective To determine the presence of glycosaminoglycans in the extracellular matrix of connective tissue from neoplastic and non-neoplastic colorectal tissues, since it has a central role in tumor development and progression. Methods Tissue samples from neoplastic and non-neoplastic colorectal tissues were obtained from 64 operated patients who had colorectal carcinoma with no distant metastases. Expressions of heparan sulphate, chondroitin sulphate, dermatan sulphate and their fragments were analyzed by electrospray ionization mass spectrometry, with the technique for extraction and quantification of glycosaminoglycans after proteolysis and electrophoresis. The statistical analysis included mean, standard deviation, and Student’s t test. Results The glycosaminoglycans extracted from colorectal tissue showed three electrophoretic bands in agarose gel. Electrospray ionization mass spectrometry showed characteristic disaccharide fragments from glycosaminoglycans, indicating their structural characterization in the tissues analyzed. Some peaks in the electrospray ionization mass spectrometry were not characterized as fragments of sugars, indicating the presence of fragments of the protein structure of proteoglycans generated during the glycosaminoglycan purification. The average amount of chondroitin and dermatan increased in the neoplastic tissue compared to normal tissue (p=0.01). On the other hand, the average amount of heparan decreased in the neoplastic tissue compared to normal tissue (p= 0.03). Conclusion The method allowed the determination of the glycosaminoglycans structural profile in colorectal tissue from neoplastic and non-neoplastic colorectal tissue. Neoplastic tissues showed greater amounts of chondroitin sulphate and dermatan sulphate compared to non-neoplastic tissues, while heparan sulphate was decreased in neoplastic tissues. PMID:26761548

  2. Variation of curve number with storm depth

    NASA Astrophysics Data System (ADS)

    Banasik, K.; Hejduk, L.

    2012-04-01

    The NRCS Curve Number (known also as SCS-CN) method is well known as a tool in predicting flood runoff depth from small ungauged catchment. The traditional way of determination the CNs, based on soil characteristics, land use and hydrological conditions, seemed to have tendency to overpredict the floods in some cases. Over 30 year rainfall-runoff data, collected in two small (A=23.4 & 82.4 km2), lowland, agricultural catchments in Center of Poland (Banasik & Woodward 2010), were used to determine runoff Curve Number and to check a tendency of changing. The observed CN declines with increasing storm size, which according recent views of Hawkins (1993) could be classified as a standard response of watershed. The analysis concluded, that using CN value according to the procedure described in USDA-SCS Handbook one receives representative value for estimating storm runoff from high rainfall depths in the analyzes catchments. This has been confirmed by applying "asymptotic approach" for estimating the watershed curve number from the rainfall-runoff data. Furthermore, the analysis indicated that CN, estimated from mean retention parameter S of recorded events with rainfall depth higher than initial abstraction, is also approaching the theoretical CN. The observed CN, ranging from 59.8 to 97.1 and from 52.3 to 95.5, in the smaller and the larger catchment respectively, declines with increasing storm size, which has been classified as a standard response of watershed. The investigation demonstrated also changeability of the CN during a year, with much lower values during the vegetation season. Banasik K. & D.E. Woodward (2010). "Empirical determination of curve number for a small agricultural watrshed in Poland". 2nd Joint Federal Interagency Conference, Las Vegas, NV, June 27 - July 1, 2010 (http://acwi.gov/sos/pubs/2ndJFIC/Contents/10E_Banasik_ 28_02_10. pdf). Hawkins R. H. (1993). "Asymptotic determination of curve numbers from data". Journal of Irrigation and Drainage

  3. Supply Curves of Conserved Energy

    SciTech Connect

    Meier, Alan Kevin

    1982-05-01

    Supply curves of conserved energy provide an accounting framework that expresses the potential for energy conservation. The economic worthiness of a conservation measure is expressed in terms of the cost of conserved energy, and a measure is considered economical when the cost of conserved energy is less than the price of the energy it replaces. A supply curve of conserved energy is independent of energy prices; however, the economical reserves of conserved energy will depend on energy prices. Double-counting of energy savings and error propagation are common problems when estimating conservation potentials, but supply curves minimize these difficulties and make their consequences predictable. The sensitivity of the cost of conserved energy is examined, as are variations in the optimal investment strategy in response to changes in inputs. Guidelines are presented for predicting the consequences of such changes. The conservation supply curve concept can be applied to peak power, water, pollution, and other markets where consumers demand a service rather than a particular good.

  4. Interpolation and Polynomial Curve Fitting

    ERIC Educational Resources Information Center

    Yang, Yajun; Gordon, Sheldon P.

    2014-01-01

    Two points determine a line. Three noncollinear points determine a quadratic function. Four points that do not lie on a lower-degree polynomial curve determine a cubic function. In general, n + 1 points uniquely determine a polynomial of degree n, presuming that they do not fall onto a polynomial of lower degree. The process of finding such a…

  5. Variability among polysulphone calibration curves

    NASA Astrophysics Data System (ADS)

    Casale, G. R.; Borra, M.; Colosimo, A.; Colucci, M.; Militello, A.; Siani, A. M.; Sisto, R.

    2006-09-01

    Within an epidemiological study regarding the correlation between skin pathologies and personal ultraviolet (UV) exposure due to solar radiation, 14 field campaigns using polysulphone (PS) dosemeters were carried out at three different Italian sites (urban, semi-rural and rural) in every season of the year. A polysulphone calibration curve for each field experiment was obtained by measuring the ambient UV dose under almost clear sky conditions and the corresponding change in the PS film absorbance, prior and post exposure. Ambient UV doses were measured by well-calibrated broad-band radiometers and by electronic dosemeters. The dose-response relation was represented by the typical best fit to a third-degree polynomial and it was parameterized by a coefficient multiplying a cubic polynomial function. It was observed that the fit curves differed from each other in the coefficient only. It was assessed that the multiplying coefficient was affected by the solar UV spectrum at the Earth's surface whilst the polynomial factor depended on the photoinduced reaction of the polysulphone film. The mismatch between the polysulphone spectral curve and the CIE erythemal action spectrum was responsible for the variability among polysulphone calibration curves. The variability of the coefficient was related to the total ozone amount and the solar zenith angle. A mathematical explanation of such a parameterization was also discussed.

  6. Breakpoint chlorination curves of greywater.

    PubMed

    March, J G; Gual, M

    2007-08-01

    A study on chlorination of raw greywater with hypochlorite is reported in this paper. Samples were chlorinated in a variety of conditions, and residual chlorine (Cl2) was measured spectrophotometrically. For each sample, the chlorination curve (chlorine residuals versus chlorine dose) was obtained. Curves showed the typical hump-and-dip profile attributable to the formation and destruction of chloramines. It was observed that, after reactions with strong reductants and chloramines-forming compounds, the remaining organic matter exerted a certain demand of chlorine. The evolution of chlorination curves with addition of ammonia and dodecylbencene sulfonate sodium salt and with dilution of the greywater sample were studied. In addition, chlorination curves at several contact times have been obtained, resulting in slower chlorine decay in the hump zone than in the dip zone. In addition, the decay of coliforms in chlorinated samples was also investigated. It was found that, for a chlorination dosage corresponding to the maximum of the hump zone (average 8.9 mg Cl2/ L), samples were negative in coliforms after 10 to 30 minutes of contact time. After-growth was not observed within 3 days after chlorination. Implications in chlorination treatments of raw greywater can be derived from these results.

  7. Optical analysis of miniature lenses with curved imaging surfaces.

    PubMed

    Reshidko, Dmitry; Sasian, Jose

    2015-10-01

    Miniature cameras for consumer electronics and mobile phones have been, and continue to be, in fast development. The system level requirements, such as manufacturing cost, packaging, and sensor characteristics, impose unique challenges for optical designers. In this paper, we discuss the potential optical benefits of having a curved image surface rather than a flat one. We show that curved sensor technology allows for optically faster lens solutions. We discuss trade-offs of several relevant characteristics, such as packaging, chief ray angle, image quality, and tolerance sensitivity. A comparison of a benchmark flat field lens, and an evaluation design imaging on a curved surface and working at f/1.6, provides useful specific insights. For a given image quality, departing from a flat imaging surface does not allow significantly reducing the total length of a lens.

  8. Electrospray Ionization Mass Spectrometry: From Cluster Ions to Toxic metal Ions in Biology

    SciTech Connect

    Lentz, Nicholas B.

    2007-01-01

    This dissertation focused on using electrospray ionization mass spectrometry to study cluster ions and toxic metal ions in biology. In Chapter 2, it was shown that primary, secondary and quarternary amines exhibit different clustering characteristics under identical instrument conditions. Carbon chain length also played a role in cluster ion formation. In Chapters 3 and 4, the effects of solvent types/ratios and various instrumental parameters on cluster ion formation were examined. It was found that instrument interface design also plays a critical role in the cluster ion distribution seen in the mass spectrum. In Chapter 5, ESI-MS was used to investigate toxic metal binding to the [Gln11]-amyloid β-protein fragment (1-16). Pb and Cd bound stronger than Zn, even in the presence of excess Zn. Hg bound weaker than Zn. There are endless options for future work on cluster ions. Any molecule that is poorly ionized in positive ion mode can potentially show an increase in ionization efficiency if an appropriate anion is used to produce a net negative charge. It is possible that drug protein or drug/DNA complexes can also be stabilized by adding counter-ions. This would preserve the solution characteristics of the complex in the gas phase. Once in the gas phase, CID could determine the drug binding location on the biomolecule. There are many research projects regarding toxic metals in biology that have yet to be investigated or even discovered. This is an area of research with an almost endless future because of the changing dynamics of biological systems. What is deemed safe today may show toxic effects in the future. Evolutionary changes in protein structures may render them more susceptible to toxic metal binding. As the understanding of toxicity evolves, so does the demand for new toxic metal research. New instrumentation designs and software make it possible to perform research that could not be done in the past. What was undetectable yesterday will

  9. Comparison of Two Algebraic Methods for Curve/curve Intersection

    NASA Technical Reports Server (NTRS)

    Demontaudouin, Y.; Tiller, W.

    1985-01-01

    Most geometric modeling systems use either polynomial or rational functions to represent geometry. In such systems most computational problems can be formulated as systems of polynomials in one or more variables. Classical elimination theory can be used to solve such systems. Here Cayley's method of elimination is summarized and it is shown how it can best be used to solve the curve/curve intersection problem. Cayley's method was found to be a more straightforward approach. Furthermore, it is computationally simpler, since the elements of the Cayley matrix are one variable instead of two variable polynomials. Researchers implemented and tested both methods and found Cayley's to be more efficient. Six pairs of curves, representing mixtures of lines, circles, and cubic arcs were used. Several examples had multiple intersection points. For all six cases Cayley's required less CPU time than the other method. The average time ratio of method 1 to method 2 was 3.13:1, the least difference was 2.33:1, and the most dramatic was 6.25:1. Both of the above methods can be extended to solve the surface/surface intersection problem.

  10. A Graphical Approach to Evaluating Equating Using Test Characteristic Curves

    ERIC Educational Resources Information Center

    Wyse, Adam E.; Reckase, Mark D.

    2011-01-01

    An essential concern in the application of any equating procedure is determining whether tests can be considered equated after the tests have been placed onto a common scale. This article clarifies one equating criterion, the first-order equity property of equating, and develops a new method for evaluating equating that is linked to this…

  11. CAPILLARY ELECTROPHORESIS-ELECTROSPRAY MASS SPECTRA OF THE HERBICIDES PARAQUAT AND DIQUAT

    EPA Science Inventory

    The positive ion electrospray mass spectra of the quaternary ammonium salt herbicides paraquat and diquat are examined by on-line separation with capillary electrophoresis (CE) and by direct infusion of the analytes. The analytes are separated by CE in 7-10 min at pH 3.9 in 50% m...

  12. Revision of capillary cone-jet physics: electrospray and flow focusing.

    PubMed

    Gañán-Calvo, Alfonso M; Montanero, José M

    2009-06-01

    Capillary cone jets are natural microfluidic structures arising in steady capillary tip streaming, whose paradigms are electrospray and flow focusing phenomena. In this work, we make a profound revision of the basic underlying physics of generic cone jets from thousands of experimental measurements, most of them reported in the literature. First, the boundaries of the stability region of steady jetting are calculated. We describe these limitations by instability mechanisms associated with the local flow structure in the tip and the issuing jet and with the global behavior of the meniscus. Second, to undertake a general physical treatment of cone jets in steady regime, we analyze the energy balance taking place in the tips of both flow focusing and electrospray. This analysis yields a fundamental result: if the electrospray data are expressed in terms of an effective pressure drop, both phenomena satisfy the same scaling law for the droplet size, which exhibits nearly complete similarity in the parameter window where quasimonodisperse sprays are produced. That effective pressure drop is a function of the liquid properties exclusively, i.e., it does not depend on the operational parameters (flow rate and applied voltage). Moreover, the stability limits of the operational regimes are analyzed in detail, finding fundamental coincidences between flow focusing and electrospray as well. These results provide most useful general description and predictive scaling laws for nearly monodisperse microspraying or nanospraying based on steady cone jets, of immediate applicability in analytical chemistry, chemical engineering, biochemistry, pharmaceutical and food technologies, painting, and many other technological fields.

  13. Laser micromachined isoelectric focusing devices on polymer substrate for electrospray mass spectrometry

    NASA Astrophysics Data System (ADS)

    Lin, Yuehe; Wen, Jenny; Fan, Xiang; Matson, Dean W.; Smith, Richard D.

    1999-08-01

    A microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using a laser micromachining technique. The separation channels on an IEF chip were 16 cm long, 50 micrometers wide and 30 micrometers deep. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, and which were isolated from the separation channel by molecular porous membranes. On-line ESI produced directly from a sharp `tip' on the microchip was evaluated. The results indicate that this design can produce a stable electrospray that is further improved and made more flexible with the assistance of sheath gas and sheath liquid. Error analysis of the spectral data shows that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 hours. The production of stable electrosprays directly from microchip IEF devices represents a step towards easily- fabricated microanalytical devices. IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. On-line IEF/ESI-MS was demonstrated using the microfabricated chip with an ion-trap ESI mass spectrometer for characterization of protein mixtures.

  14. Identification of tetraacylglycerols in lesquerella oil by electrospray ionization mass spectrometry of the lithium adducts

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Tetraacylglycerol (an acylglycerol estolide) contains an acyl chain attached to the hydroxyl group of another acyl chain attached to the glycerol backbone. Lequerolic acid (Ls, OH1420:111) is the main fatty acid in lequerella oil and can be used in industry. We have used electrospray ionization mass...

  15. The classification of gunshot residue using laser electrospray mass spectrometry and offline multivariate statistical analysis

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Nonresonant laser vaporization combined with high-resolution electrospray time-of-flight mass spectrometry enables analysis of a casing after discharge of a firearm revealing organic signature molecules including methyl centralite (MC), diphenylamine (DPA), N-nitrosodiphenylamine (N-NO-DPA), 4-nitro...

  16. Generation of naphthoquinone radical anions by electrospray ionization: solution, gas-phase, and computational chemistry studies.

    PubMed

    Vessecchi, Ricardo; Naal, Zeki; Lopes, José N C; Galembeck, Sérgio E; Lopes, Norberto P

    2011-06-02

    Radical anions are present in several chemical processes, and understanding the reactivity of these species may be described by their thermodynamic properties. Over the last years, the formation of radical ions in the gas phase has been an important issue concerning electrospray ionization mass spectrometry studies. In this work, we report on the generation of radical anions of quinonoid compounds (Q) by electrospray ionization mass spectrometry. The balance between radical anion formation and the deprotonated molecule is also analyzed by influence of the experimental parameters (gas-phase acidity, electron affinity, and reduction potential) and solvent system employed. The gas-phase parameters for formation of radical species and deprotonated species were achieved on the basis of computational thermochemistry. The solution effects on the formation of radical anion (Q(•-)) and dianion (Q(2-)) were evaluated on the basis of cyclic voltammetry analysis and the reduction potentials compared with calculated electron affinities. The occurrence of unexpected ions [Q+15](-) was described as being a reaction between the solvent system and the radical anion, Q(•-). The gas-phase chemistry of the electrosprayed radical anions was obtained by collisional-induced dissociation and compared to the relative energy calculations. These results are important for understanding the formation and reactivity of radical anions and to establish their correlation with the reducing properties by electrospray ionization analyses.

  17. Hands-on Electrospray Ionization-Mass Spectrometry for Upper-Level Undergraduate and Graduate Students

    ERIC Educational Resources Information Center

    Stock, Naomi L.; March, Raymond E.

    2014-01-01

    Electrospray ionization-mass spectrometry (ESI-MS) is a powerful technique for the detection, identification, and quantification of organic compounds. As mass spectrometers have become more user-friendly and affordable, many students--often with little experience in mass spectrometry--find themselves needing to incorporate mass spectrometry into…

  18. Electrospray painted article containing thermally exfoliated graphite oxide and method for their manufacture

    NASA Technical Reports Server (NTRS)

    Korkut, Sibel (Inventor); Prud'Homme, Robert K. (Inventor); Aksay, Ilhan A. (Inventor)

    2011-01-01

    A painted polymer part containing a conductive polymer composition containing at least one polymer and a modified graphite oxide material, which is a thermally exfoliated graphite oxide with a surface area of from about 300 sq m/g to 2600 sq m/g, wherein the painted polymer part has been electrospray painted.

  19. Electrospray deposition of titanium dioxide (TiO{sub 2}) nanoparticles

    SciTech Connect

    Halimi, Siti Umairah Bakar, Noor Fitrah Abu Ismail, Siti Norazian Hashib, Syafiza Abd; Naim, M. Nazli

    2014-02-24

    Deposition of titanium dioxide (TiO{sub 2}) nanoparticles was conducted by using eletrospray method. 0.05wt% of titanium dioxide suspension was prepared and characterized by using Malvern Zetasizer prior to the experiment. From Zetasizer results, stable suspension condition was obtained which is at pH 2 with zeta potential value of ±29.0 mV. In this electrospraying, the suspension was pumped at flowrate of 5 ml/hr by using syringe pump. The input voltage of 2.1 kV was applied at the nozzle tip and counter electrode. Electrosprayed particles were collected on the grounded aluminium plate substrate which was placed at 10–20 cm from counter electrode. Particles were then characterized using FESEM and average size of electrosprayed particles obtained. Initial droplet size was calculated by scaling law and compared with FE-SEM results in order to prove droplet fission occur during electrospray. Due to the results obtained, as the working distance increase from 10–20 cm the deposited TiO{sub 2} droplet size decrease from 247–116 nm to show droplet fission occur during the experiment.

  20. EMllM Wetting Properties and their Effect on Electrospray Thruster Design

    DTIC Science & Technology

    2012-03-01

    measurements: (t) & (t) 8DISTRIBUTION A: Approved for public release; distribution is unlimited Methodology Methodology • Contact Angle ( Sessile Drop ...Technique) • Surface Tension (Pendant Drop Technique) • Simulate On-Orbit Electrospray Environment • Determine Optimal Materials & Conditions Contact Angle ...static equilibrium droplet Variation in (T), counter-intuitive Temperature rises / Surface tension drops / Contact angle increases, greater change in

  1. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    SciTech Connect

    Johnson, Steven

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  2. Protective effects of dimethyl sulfoxide on labile protein interactions during electrospray ionization.

    PubMed

    Landreh, Michael; Alvelius, Gunvor; Johansson, Jan; Jörnvall, Hans

    2014-05-06

    Electrospray ionization mass spectrometry is a valuable tool to probe noncovalent interactions. However, the integrity of the interactions in the gas-phase is heavily influenced by the ionization process. Investigating oligomerization and ligand binding of transthyretin (TTR) and the chaperone domain from prosurfactant protein C, we found that dimethyl sulfoxide (DMSO) can improve the stability of the noncovalent interactions during the electrospray process, both regarding ligand binding and the protein quaternary structure. Low amounts of DMSO can reduce in-source dissociation of native protein oligomers and their interactions with hydrophobic ligands, even under destabilizing conditions. We interpret the effects of DMSO as being derived from its enrichment in the electrospray droplets during evaporation. Protection of labile interactions can arise from the decrease in ion charges to reduce the contributions from Coulomb repulsions, as well as from the cooling effect of adduct dissociation. The protective effects of DMSO on labile protein interactions are an important property given its widespread use in protein analysis by electrospray ionization mass spectrometry (ESI-MS).

  3. Examination and Manipulation of Protein Surface Charge in Solution with Electrospray Ionization Mass Spectrometry

    ERIC Educational Resources Information Center

    Gross, Deborah S.; Van Ryswyk, Hal

    2014-01-01

    Electrospray ionization mass spectrometry (ESI-MS) is a powerful tool for examining the charge of proteins in solution. The charge can be manipulated through choice of solvent and pH. Furthermore, solution-accessible, protonated lysine side chains can be specifically tagged with 18-crown-6 ether to form noncovalent adducts. Chemical derivatization…

  4. Design, simulation, and fabrication of a MEMS-based air amplifier for electrospray ionization

    NASA Astrophysics Data System (ADS)

    Jurčíček, Petr; Zou, Helin; Gao, Shuai

    2013-04-01

    Recent developments in electrospray ionization mass spectrometry (ESI-MS) show that air amplifiers can be utilized to significantly enhance droplet desolvation and to focus gas-phase ions when provided between an electrospray (ES) source and the mass spectrometer (MS). However, these devices are bulky and expensive, which may be a factor prohibiting their broader utilization. We have developed a simple but effective method based on Bernoulli's principle, the Coanda effect and MEMS processing to focus electrosprayed droplets and liberated gas-phase ions. We demonstrate a computer simulation and fabrication process for a micromachined air amplifier. The simulation results are used to optimize the geometry and to meet performance requirements. The optimized results then provide a design guideline for the device's fabrication. The air amplifier is formed from two bonded polydimethylsiloxane (PDMS) casts. Each PDMS cast is fabricated through a molding process using a micromachined two-layer SU-8 mold. Experimental results show a 30-fold improvement in the ES current for certain operation conditions while the air amplifier is incorporated in the nano-electrospray ionization (nano-ESI) process. Compared with traditional air amplifiers, the micro-electro-mechanical systems (MEMS) based air amplifier provides good performance while keeping the fabrication process simple and cost effective.

  5. Extractive Electrospray Ionization Mass Spectrometry of Heterogeneous Particles: Implications for Applications to Complex Atmospheric Aerosol

    NASA Astrophysics Data System (ADS)

    Longin, T.; Waring-Kidd, C.; Wingen, L. M.; Lyster, K.; Anderson, C.; Kumbhani, S.; Finlayson-Pitts, B. J.

    2015-12-01

    Extractive electrospray ionization mass spectrometry (EESI-MS) is a direct, real time technique for obtaining mass spectra of gases, liquid droplets, solid particles, and aerosols with little sample processing. EESI-MS involves the interaction of charged electrospray droplets with a separate spray containing the analyte of interest, but the exact mechanism by which the solvent droplets extract analyte from the sample is unclear. Possible mechanisms include complete coalescence of the sample particle with the solvent droplet in which all of the analyte is incorporated into the solvent or a more temporary interaction such that only some of the analyte is transferred to the solvent. Previous studies of the mechanism of EESI-MS on homogeneous particles indicate that both mechanisms are possible. We studied the behavior of EESI-MS toward heterogeneous particles created by coating NaCl particles with various thicknesses of organic diacids. Our results indicate that the signal strength depends on the solubility of the organic acid in the electrospray solvent, in agreement with previous studies, and also that the outer 10-15 nm of the particles are most susceptible to extraction into the electrospray droplets. Our results combined with those of previous studies suggest that the mass spectra obtained with EESI will not necessarily reflect the overall particle composition, especially for particles that are spatially inhomogeneous, and hence caution in interpretation of the data is advised for application to complex atmospheric aerosol.

  6. K2 Mission Light Curves

    NASA Astrophysics Data System (ADS)

    Smith, Jeffrey C.; morris, robert; Bryson, Steve; Jenkins, Jon Michael; Caldwell, Douglas

    2015-08-01

    The K2 mission is now generating light curves for its ecliptic-field campaigns. Producing good photometry for K2 is more challenging than for Kepler’s prime mission because periodic thruster firings are used to compensate for the loss of two reaction wheels. These firings, referred to as "roll tweaks", result in spacecraft rotation along the barrel axis and high corresponding image motion. The resulting motion-dominated systematic errors are dramatically different than the focus-dominated systematic errors experienced during the prime mission. They also make it challenging to properly identify and remove flux from background objects present in the optimal apertures. We summarize these challenges and describe the resulting modifications to the Kepler pipeline for the processing of K2 data. The quality of the K2 mission light curves is characterized.

  7. Infinite swapping in curved spaces

    NASA Astrophysics Data System (ADS)

    Curotto, E.; Mella, Massimo

    2014-01-01

    We develop an extension of the infinite swapping and partial infinite swapping techniques [N. Plattner, J. D. Doll, P. Dupuis, H. Wang, Y. Liu, and J. E. Gubernatis, J. Chem. Phys. 135, 134111 (2011)] to curved spaces. Furthermore, we test the performance of infinite swapping and partial infinite swapping in a series of flat spaces characterized by the same potential energy surface model. We develop a second order variational algorithm for general curved spaces without the extended Lagrangian formalism to include holonomic constraints. We test the new methods by carrying out NVT classical ensemble simulations on a set of multidimensional toroids mapped by stereographic projections and characterized by a potential energy surface built from a linear combination of decoupled double wells shaped purposely to create rare events over a range of temperatures.

  8. Infinite swapping in curved spaces.

    PubMed

    Curotto, E; Mella, Massimo

    2014-01-07

    We develop an extension of the infinite swapping and partial infinite swapping techniques [N. Plattner, J. D. Doll, P. Dupuis, H. Wang, Y. Liu, and J. E. Gubernatis, J. Chem. Phys. 135, 134111 (2011)] to curved spaces. Furthermore, we test the performance of infinite swapping and partial infinite swapping in a series of flat spaces characterized by the same potential energy surface model. We develop a second order variational algorithm for general curved spaces without the extended Lagrangian formalism to include holonomic constraints. We test the new methods by carrying out NVT classical ensemble simulations on a set of multidimensional toroids mapped by stereographic projections and characterized by a potential energy surface built from a linear combination of decoupled double wells shaped purposely to create rare events over a range of temperatures.

  9. Analysis of Exoplanet Light Curves

    NASA Astrophysics Data System (ADS)

    Erdem, A.; Budding, E.; Rhodes, M. D.; Püsküllü, Ç.; Soydugan, F.; Soydugan, E.; Tüysüz, M.; Demircan, O.

    2015-07-01

    We have applied the close binary system analysis package WINFITTER to a variety of exoplanet transiting light curves taken both from the NASA Exoplanet Archive and our own ground-based observations. WINFitter has parameter options for a realistic physical model, including gravity brightening and structural parameters derived from Kopal's applications of the relevant Radau equation, and it includes appropriate tests for determinacy and adequacy of its best fitting parameter sets. We discuss a number of issues related to empirical checking of models for stellar limb darkening, surface maculation, Doppler beaming, microvariability, and transit time variation (TTV) effects. The Radau coefficients used in the light curve modeling, in principle, allow structural models of the component stars to be tested.

  10. High speed curved position sensitive detector

    DOEpatents

    Hendricks, Robert W.; Wilson, Jack W.

    1989-01-01

    A high speed curved position sensitive porportional counter detector for use in x-ray diffraction, the detection of 5-20 keV photons and the like. The detector employs a planar anode assembly of a plurality of parallel metallic wires. This anode assembly is supported between two cathode planes, with at least one of these cathode planes having a serpentine resistive path in the form of a meander having legs generally perpendicular to the anode wires. This meander is produced by special microelectronic fabrication techniques whereby the meander "wire" fans outwardly at the cathode ends to produce the curved aspect of the detector, and the legs of the meander are small in cross-section and very closely spaced whereby a spatial resolution of about 50 .mu.m can be achieved. All of the other performance characteristics are about as good or better than conventional position sensitive proportional counter type detectors. Count rates of up to 40,000 counts per second with 0.5 .mu.s shaping time constants are achieved.

  11. Accelerating Around an Unbanked Curve

    NASA Astrophysics Data System (ADS)

    Mungan, Carl E.

    2006-02-01

    The December 2004 issue of TPT presented a problem concerning how a car should accelerate around an unbanked curve of constant radius r starting from rest if it is to avoid skidding. Interestingly enough, two solutions were proffered by readers.2 The purpose of this note is to compare and contrast the two approaches. Further experimental investigation of various turning strategies using a remote-controlled car and overhead video analysis could make for an interesting student project.

  12. Forced convective heat transfer in curved diffusers

    NASA Technical Reports Server (NTRS)

    Rojas, J.; Whitelaw, J. H.; Yianneskis, M.

    1987-01-01

    Measurements of the velocity characteristics of the flows in two curved diffusers of rectangular cross section with C and S-shaped centerlines are presented and related to measurements of wall heat transfer coefficients along the heated flat walls of the ducts. The velocity results were obtained by laser-Doppler anemometry in a water tunnel and the heat transfer results by liquid crystal thermography in a wind tunnel. The thermographic technique allowed the rapid and inexpensive measurement of wall heat transfer coefficients along flat walls of arbitrary boundary shapes with an accuracy of about 5 percent. The results show that an increase in secondary flow velocities near the heated wall causes an increase in the local wall heat transfer coefficient, and quantify the variation for maximum secondary-flow velocities in a range from 1.5 to 17 percent of the bulk flow velocity.

  13. Inferring asymmetric limb cloudiness on exoplanets from transit light curves

    NASA Astrophysics Data System (ADS)

    von Paris, P.; Gratier, P.; Bordé, P.; Leconte, J.; Selsis, F.

    2016-05-01

    Context. Clouds have been shown to be present in many exoplanetary atmospheres. Cloud formation modeling predicts considerable inhomogeneities of cloud cover, consistent with optical phase curve observations. However, optical phase curves cannot resolve some existing degeneracies between cloud location and cloud optical properties. Aims: We present a conceptually simple technique for detecting inhomogeneous cloud cover on exoplanets. Such an inhomogeneous cloud cover produces an asymmetric primary transit of the planet in front of the host star. Asymmetric transits produce characteristic residuals that are different from standard symmetric models. Furthermore, bisector spans can be used to determine asymmetries in the transit light curve. Methods: We apply a model of asymmetric transits to the light curves of HAT-P-7b, Kepler-7b, and HD 209458b and search for possible cloud signatures. The nearly uninterrupted Kepler photometry is particularly well suited for this method since it allows for a very high time resolution. Results: We do not find any statistically sound cloud signature in the data of the considered planets. For HAT-P-7b, a tentative detection of an asymmetric cloud cover is found, consistent with analysis of the optical phase curve. Based on Bayesian probability arguments, a symmetric model with an offset in the transit ephemeris is still the most viable model. This work demonstrates that for suitable targets, namely low-gravity planets around bright stars, the method can be used to constrain cloud cover characteristics and is thus a helpful additional tool for the study of exoplanetary atmospheres.

  14. Evaluation of Electrospray as a Sample Preparation Tool for Electron Microscopic Investigations: Toward Quantitative Evaluation of Nanoparticles.

    PubMed

    Mielke, Johannes; Dohányosová, Pavla; Müller, Philipp; López-Vidal, Silvia; Hodoroaba, Vasile-Dan

    2017-02-01

    The potential of electrospray deposition, for the controlled preparation of particles for imaging in electron microscopes, is evaluated on various materials: from mono-modal suspensions of spherical particles to multimodal suspensions and to real-world industrial materials. It is shown that agglomeration is reduced substantially on the sample carrier, compared with conventional sample preparation techniques. For the first time, it is possible to assess the number concentration of a tri-modal polystyrene suspension by electron microscopy, due to the high deposition efficiency of the electrospray. We discovered that some suspension stabilizing surfactants form artifact particles during electrospraying. These can be avoided by optimizing the sprayed suspension.

  15. Electrospray ionization FT-ICR/MS Investigation of Zinc Sulfate Clusters

    NASA Astrophysics Data System (ADS)

    Chen, K.; Lemke, K.

    2013-12-01

    Zinc sulfate (ZnSO4) is a common salt present in oxidized surface waters and may serve as a suitable model material to better understand precipitation/nucleation processes in aqueous fluids. In brief, precipitation of ZnSO4 commences with single molecule association (complexation) reactions and proceeds via a wide range of prenucleation clusters (ZnSO4)n and nanocrystalites ultimately toward bulk ZnSO4. Evidently, ZnSO4 growth will pass through the cluster-size domain, from which small ZnSO4 cluster subunits emerge with characteristic chain, sheet and 3-D structures. This experimental study focuses on small zinc sulfate clusters and provides a set of preliminary results pertaining to the stoichiometry, abundance and stability of these materials in aqueous environments. At present, very little is known with respect to the composition, structure and stability of ZnSO4 at the cluster level, however, electrospray ionization (ESI) mass spectrometry can provide detailed insight into the aforementioned features of ZnSO4. In addition, application of resonance techniques, such as high-resolution Fourier Transfer Ion Cyclotron Resonance Mass Spectrometry (FT-ICR/MS) provides detailed information with respect to the molecular composition of individual ion clusters at high resolution. Here we present the stoichiometries of zinc sulfate ion clusters identified using FT-ICR/MS. In 15mM dilute aqueous solution of zinc sulfate, singly-charged ion clusters [Znm(SO4)m-1(OH)●(H2O)n]+ with m=2, 3, 4 and 5 have been identified. In addition, a set of doubly-charged clusters with the general form [Znm(SO4)m-1●(H2O)n]2+ with 4≤m≤10 have been characterized. We will propose a scheme, in which singly-charged cluster species with m=4,5 are regarded to be of a critical-size from which stable doubly-charged ions begin to emerge. Upon passing the m~4-5 size-range, zinc sulfate clusters exhibit a strong affinity towards water with stable hepta-hydrates marking the upper range of

  16. Light bullets in nonlinear periodically curved waveguide arrays

    SciTech Connect

    Matuszewski, Michal; Garanovich, Ivan L.; Sukhorukov, Andrey A.

    2010-04-15

    We predict that stable mobile spatiotemporal solitons can exist in arrays of periodically curved optical waveguides. We find two-dimensional light bullets in planar arrays with harmonic waveguide bending and three-dimensional bullets in square lattices with helical waveguide bending using variational formalism. Stability of the light-bullet solutions is confirmed by the direct numerical simulations which show that the light bullets can freely move across the curved arrays. This mobility property is a distinguishing characteristic compared to previously considered discrete light bullets which were trapped to a specific lattice site. These results suggest new possibilities for flexible spatiotemporal manipulation of optical pulses in photonic lattices.

  17. Particle filtering for dispersion curve tracking in ocean acoustics.

    PubMed

    Zorych, Ivan; Michalopoulou, Zoi-Heleni

    2008-08-01

    A particle filtering method is developed for dispersion curve extraction from spectrograms of broadband acoustic signals propagating in underwater media. The goal is to obtain accurate representation of modal dispersion which can be employed for source localization and geoacoustic inversion. Results are presented from the application of the method to synthetic data, demonstrating the potential of the approach for accurate estimation of waveguide dispersion characteristics. The method outperforms simple time-frequency analysis providing estimates that are very close to numerically calculated dispersion curves. The method also provides uncertainty information on modal arrival time estimates, typically unavailable when traditional methods are used.

  18. High performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) method for simultaneous determination of venlafaxine and its three metabolites in human plasma.

    PubMed

    Liu, Wen; Cai, Hua-Lin; Li, Huan-de

    2007-05-01

    A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its three metabolites O-desmethylvenlafaxine (ODV), N-desmethylvenlafaxine (NDV) and N,O-didesmethylvenlafaxine (DDV) in human plasma has been developed and validated. Estazolam was used as the internal standard. The compounds and internal standard were extracted from plasma by a liquid-liquid extraction. The HPLC separation of the analytes was performed on a Thermo BDS HYPERSIL C18 (250 mm x 4.6 mm, 5 microm, USA) column, using a gradient elution program with solvents constituted of water (ammonium acetate: 30 mmol/l, formic acid 2.6 mmol/l and trifluoroacetic acid 0.13 mmol/l) and acetonitrile (60:40, V/V) at a flow-rate of 1.0 ml/min. All of the analytes were eluted within 6 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and were detected in the selected ion recording (SIR) mode. Calibration curves in spiked whole blood were linear from 4.0-700 ng/ml, 2.0-900 ng/ml, 3.0-800 ng/ml and 2.0-700 ng/ml for VEN, ODV, NDV and DDV, respectively, all of them with coefficients of determination above 0.9991. The average extraction recoveries for all the four analytes were above 77%. The methodology recoveries were higher than 91%. The limits of detection were 0.4, 0.2, 0.3, and 0.2 ng/ml for VEN, ODV, NDV and DDV, respectively. The intra- and inter-day variation coefficients were less than 11%. The method is accurate, sensitive and reliable for the pharmacokinetic study of venlafaxine as well as therapeutic drug monitoring (TDM).

  19. Compression of contour data through exploiting curve-to-curve dependence

    NASA Technical Reports Server (NTRS)

    Yalabik, N.; Cooper, D. B.

    1975-01-01

    An approach to exploiting curve-to-curve dependencies in order to achieve high data compression is presented. One of the approaches to date of along curve compression through use of cubic spline approximation is taken and extended by investigating the additional compressibility achievable through curve-to-curve structure exploitation. One of the models under investigation is reported on.

  20. Investigations of bonded and curved microchannel plate stacks

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.

    1988-01-01

    The technique of fusing, or bonding, individual microchannel plate (MCP) stacks together offers the possibility of improving the uniformity of MCP stack operating characteristics and provides a convenient monolithic format. Here, the effectiveness of bonded MCP stacks and stacks of MCPs with curved surfaces is investigated to determine if MCP requirements for future astrophysical detectors can be achieved. The results show that both configurations give superior MCP performance characteristics. However, some problems remain with regard to the fabrication of bonded MCP stacks resulting in poor flat field characteristics and increased background.

  1. NLINEAR - NONLINEAR CURVE FITTING PROGRAM

    NASA Technical Reports Server (NTRS)

    Everhart, J. L.

    1994-01-01

    A common method for fitting data is a least-squares fit. In the least-squares method, a user-specified fitting function is utilized in such a way as to minimize the sum of the squares of distances between the data points and the fitting curve. The Nonlinear Curve Fitting Program, NLINEAR, is an interactive curve fitting routine based on a description of the quadratic expansion of the chi-squared statistic. NLINEAR utilizes a nonlinear optimization algorithm that calculates the best statistically weighted values of the parameters of the fitting function and the chi-square that is to be minimized. The inputs to the program are the mathematical form of the fitting function and the initial values of the parameters to be estimated. This approach provides the user with statistical information such as goodness of fit and estimated values of parameters that produce the highest degree of correlation between the experimental data and the mathematical model. In the mathematical formulation of the algorithm, the Taylor expansion of chi-square is first introduced, and justification for retaining only the first term are presented. From the expansion, a set of n simultaneous linear equations are derived, which are solved by matrix algebra. To achieve convergence, the algorithm requires meaningful initial estimates for the parameters of the fitting function. NLINEAR is written in Fortran 77 for execution on a CDC Cyber 750 under NOS 2.3. It has a central memory requirement of 5K 60 bit words. Optionally, graphical output of the fitting function can be plotted. Tektronix PLOT-10 routines are required for graphics. NLINEAR was developed in 1987.

  2. Sound propagation over curved barriers

    NASA Technical Reports Server (NTRS)

    Pierce, Allan D.; Main, Geoffrey L.; Kearns, James A.; Hsieh, H.-A.

    1986-01-01

    Wide barriers with curved tops are studied with emphasis placed on circumstances whereby the local radius of curvature R of the barrier is continuous along the surface and is large compared to a wavelength. Results analogous to those given by Hayek et al. (1978) are reviewed and extended to cases where the radius of curvature and the surface impedance may vary with position. Circumstances not easily interpreted within the framework of the model proposed by Keller (1956) and Hayek et al. are also considered.

  3. Sound propagation over curved barriers

    NASA Astrophysics Data System (ADS)

    Pierce, Allan D.; Main, Geoffrey L.; Kearns, James A.; Hsieh, H.-A.

    Wide barriers with curved tops are studied with emphasis placed on circumstances whereby the local radius of curvature R of the barrier is continuous along the surface and is large compared to a wavelength. Results analogous to those given by Hayek et al. (1978) are reviewed and extended to cases where the radius of curvature and the surface impedance may vary with position. Circumstances not easily interpreted within the framework of the model proposed by Keller (1956) and Hayek et al. are also considered.

  4. Dirac's aether in curved spacetime.

    PubMed

    Oliveira; Teixeira

    2000-06-01

    Proca's equations for two types of fields in a Dirac's aether with electric conductivity sigma are solved exactly. The Proca electromagnetic fields are assumed with cylindrical symmetry. The background is a static, curved spacetime whose spatial section is homogeneous and has the topology of either the three-sphere S 3 or the projective three-space P 3. Simple relations between the range of Proca field lambda, the Universe radius R, the limit of photon rest mass mgamma and the conductivity sigma are written down.

  5. Curved microchannels and bacterial streamers

    NASA Astrophysics Data System (ADS)

    Rusconi, Roberto; Lecuyer, Sigolene; Guglielmini, Laura; Stone, Howard

    2010-03-01

    Bacterial biofilms are commonly identified as microbial communities attached to a surface and encased in a self-secreted extracellular matrix. Due to their increased resistance to antimicrobial agents, biofilms have an enormous impact on health and medicine (e.g., wound healing, implant-associated infections, disease transmission). On the other hand, they constitute a major component of the stream ecosystem by increasing transport of nutrients and retention of suspended particles. In this talk, we present an experimental study of bacterial biofilm development in a microfluidic device. In particular, we show the formation of filamentous structures, or streamers, in curved channels and how these suspended biofilms are linked to the underlying hydrodynamics.

  6. Coupling desorption electrospray ionization with solid-phase microextraction for screening and quantitative analysis of drugs in urine.

    PubMed

    Kennedy, Joseph H; Aurand, Craig; Shirey, Robert; Laughlin, Brian C; Wiseman, Justin M

    2010-09-01

    Direct analysis of silica C(18)-coated solid-phase microextraction (SPME) fibers using desorption electrospray ionization mass spectrometry (DESI-MS) for the purpose of analyzing drugs from raw urine is presented. The method combines a simple, inexpensive, and solvent-less sample preparation technique with the specificity and speed of DESI-MS and MS/MS. Extraction of seven drugs from raw urine is performed using specially designed SPME fibers coated uniformly with silica-C(18) stationary phase. Each SPME device is inserted into unprocessed urine under gentle agitation and, then, removed, rinsed, and analyzed directly by DESI-MS (MS/MS). Rapid screening over a wide mass range is afforded by coupling the method with a time of flight (TOF) mass spectrometer while quantitative analysis is performed using selected reaction monitoring (SRM) using a triple quadrupole mass spectrometer. The performance of the SPME DESI-MS/MS method was evaluated by preparing calibration standards and quality control (QC) samples of the seven drug compounds from urine over a range from 20 to 1000 ng/mL, with the exception of meprobamate which was prepared from 200 to 10000 ng/mL. The calibration curves constructed for each analyte had an R(2) > 0.99. The range of precision (%CV) and accuracy values (% bias) for low QC samples was 1-11% and 3-38%, respectively. Precision and accuracy values for high QC samples range from 0.9 to 8% and -31 to -8%. Results from urine specimens of actual exposure to drugs screened using the SPME DESI-MS/MS method showed good agreement with the conventional immunoassays and GC/MS analysis. Liquid desorption of the SPME fiber followed by LC/MS/MS also showed good agreement with the SPME DESI-MS/MS method.

  7. Trace element analysis of aqueous samples by laser-induced breakdown spectroscopy based on pre-concentration of electrospray

    NASA Astrophysics Data System (ADS)

    Ni, Kai; Lei, Yu; Yu, Quan; Li, Jianan; Qian, Xiang; Wang, Xiaohao

    2015-08-01

    Laser-induced breakdown spectroscopy (LIBS) is characterized as a powerful tool in in-situ online analysis with its fast and multiple detecting abilities. But in the area of detecting trace sample in aqueous solution of low concentration, the turbulence, scattering, absorbance and cooling effect of liquid medium limits its performance. Traditional method includes liquid jet, liquid-solid transformation and pre-concentration on other medium, yet the procedure of sample preparation is complicated and time consuming. In this work, we propose a new method to achieve pre-concentration, in which filter paper and electro-spray ionization (ESI) are used. In our experiment, we choose MnSO4 as sample. The surface of filter paper is sprayed with MnSO4 aqueous solution of different concentration by an ESI. The pulsed laser is focused on the surface of filter paper and the plasma is formed in the focusing area. Through an optical fiber the spectrum of plasma is detected by a spectrometer. The ESI system, pulses generator system and the UI on PC are home-made. The spectra lines of Mn at 257.6nm, 259.4nm and 260.6nm are analyzed. Results show that the limit of detection at 257.6nm is sub-ppb and the R2 of calibration curve is more than 0.93. Compared with traditional method, like soak and drip processing, our method can increase the concentration of the sample by simply expanding spraying time, achieving a higher signal-to-noise ratio (SNR) and a lower limit of detection (LOD). In addition, the consumption of sample solution is as low as several hundred μl in each detection.

  8. Quantitative determination of the diastereoisomers of hexabromocyclododecane in human plasma using liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Tang, Caiming

    2010-12-01

    A sensitive, simple and feasible method has been developed and validated for the simultaneous determination of three diastereoisomers of hexabromocyclododecane (HBCD) in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS). The simple pretreatment generally involved protein precipitation with methanol (MeOH). The separation was performed with a C18 reverse phase column. The mobile phases were 5mM ammonium acetate (NH(4)AC) in water and acetonitrile (ACN). The mass spectrometer was operated using negative electrospray ionization (ESI) source and the data acquisition was carried out with multiple reaction monitoring (MRM) mode. The analyte quantifications were performed by external standard method with matrix-matched calibration curves. The method was partially validated with the evaluations of accuracy, precision, linearity, limit of quantification (LOQ), limit of detection (LOD), recovery, matrix effect and carryover effect. With the present method, the intra-batch accuracies were 94.7-104.3%, 91.9-109.3% and 89.8-105.0% for α-, β- and γ-HBCD, respectively. And the inter-batch accuracies were ranged from 94.2% to 109.7%. Both intra-batch and inter-batch precisions (relative standard deviation, RSD, %) of the analytes were no more than 11.2%. The recoveries were from 79.0% to 108.9% and the LOQ was 10pg/mL for each diastereoisomer. The linear range was 10-10,000pg/mL with the linear correlation coefficient R(2)>0.996. No significant matrix effect and carryover effect of the analytes were observed in this study. This method is in possession of sufficient resolution, high sensitivity as well as selectivity and convenient to be applied to the trace determination of HBCDs in human plasma.

  9. The quantitative surface analysis of an antioxidant additive in a lubricant oil matrix by desorption electrospray ionization mass spectrometry

    PubMed Central

    Da Costa, Caitlyn; Reynolds, James C; Whitmarsh, Samuel; Lynch, Tom; Creaser, Colin S

    2013-01-01

    RATIONALE Chemical additives are incorporated into commercial lubricant oils to modify the physical and chemical properties of the lubricant. The quantitative analysis of additives in oil-based lubricants deposited on a surface without extraction of the sample from the surface presents a challenge. The potential of desorption electrospray ionization mass spectrometry (DESI-MS) for the quantitative surface analysis of an oil additive in a complex oil lubricant matrix without sample extraction has been evaluated. METHODS The quantitative surface analysis of the antioxidant additive octyl (4-hydroxy-3,5-di-tert-butylphenyl)propionate in an oil lubricant matrix was carried out by DESI-MS in the presence of 2-(pentyloxy)ethyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate as an internal standard. A quadrupole/time-of-flight mass spectrometer fitted with an in-house modified ion source enabling non-proximal DESI-MS was used for the analyses. RESULTS An eight-point calibration curve ranging from 1 to 80 µg/spot of octyl (4-hydroxy-3,5-di-tert-butylphenyl)propionate in an oil lubricant matrix and in the presence of the internal standard was used to determine the quantitative response of the DESI-MS method. The sensitivity and repeatability of the technique were assessed by conducting replicate analyses at each concentration. The limit of detection was determined to be 11 ng/mm2 additive on spot with relative standard deviations in the range 3–14%. CONCLUSIONS The application of DESI-MS to the direct, quantitative surface analysis of a commercial lubricant additive in a native oil lubricant matrix is demonstrated. © 2013 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons, Ltd. PMID:24097398

  10. STRUCTURAL DETERMINATION AND QUANTITATIVE ANALYSIS OF BACTERIAL PHOSPHOLIPIDS USING LIQUID CHROMATOGRAPHY/ELECTROSPRAY IONIZATION/MASS SPECTROMETRY

    EPA Science Inventory

    This report presents a comprehensive spectral analysis of common bacterial phospholipids using electrospray/mass spectrometry (ESI/MS) under both negative and positive ionization conditions. Phospholipids under positive ionization yield sodium-adduct molecular ions which are mos...

  11. In-Situ Organic Compound Analysis of the Meteorite Surface by Desorption Electrospray Ionization Coupled with an Orbitrap Mass Spectrometer

    NASA Astrophysics Data System (ADS)

    Naraoka, H.; Hashiguchi, M.

    2016-08-01

    It-situ analysis of organic compounds on the meteorite surface was performed by desorption electrospray ionization coupled with high resolution mass spectrometry. Indigenous peaks of meteorite origin were discriminated from the background.

  12. A Study of the Complexation of Mercury(II) with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry.

    PubMed

    Mazlo, Johanna; Ngu-Schwemlein, Maria

    2016-01-08

    In this study we evaluated a method for the characterization of complexes, formed in different relative ratios of mercury(II) to dicysteinyl tetrapeptide, by electrospray ionization orbitrap mass spectrometry. This strategy is based on previous successful characterization of mercury-dicysteinyl complexes involving tripeptides by utilizing mass spectrometry among other techniques. Mercury(II) chloride and a dicysteinyl tetrapeptide were incubated in a degassed buffered medium at varying stoichiometric ratios. The complexes formed were subsequently analyzed on an electrospray mass spectrometer consisting of a hybrid linear ion- and orbi- trap mass analyzer. The electrospray ionization mass spectrometry (ESI-MS) spectra were acquired in the positive mode and the observed peaks were then analyzed for distinct mercury isotopic distribution patterns and associated monoisotopic peak. This work demonstrates that an accurate stoichiometry of mercury and peptide in the complexes formed under specified electrospray ionization conditions can be determined by using high resolution ESI MS based on distinct mercury isotopic distribution patterns.

  13. Improved capacitive melting curve measurements

    NASA Astrophysics Data System (ADS)

    Sebedash, Alexander; Tuoriniemi, Juha; Pentti, Elias; Salmela, Anssi

    2009-02-01

    Sensitivity of the capacitive method for determining the melting pressure of helium can be enhanced by loading the empty side of the capacitor with helium at a pressure nearly equal to that desired to be measured and by using a relatively thin and flexible membrane in between. This way one can achieve a nanobar resolution at the level of 30 bar, which is two orders of magnitude better than that of the best gauges with vacuum reference. This extends the applicability of melting curve thermometry to lower temperatures and would allow detecting tiny anomalies in the melting pressure, which must be associated with any phenomena contributing to the entropy of the liquid or solid phases. We demonstrated this principle in measurements of the crystallization pressure of isotopic helium mixtures at millikelvin temperatures by using partly solid pure 4He as the reference substance providing the best possible universal reference pressure. The achieved sensitivity was good enough for melting curve thermometry on mixtures down to 100 μK. Similar system can be used on pure isotopes by virtue of a blocked capillary giving a stable reference condition with liquid slightly below the melting pressure in the reference volume. This was tested with pure 4He at temperatures 0.08-0.3 K. To avoid spurious heating effects, one must carefully choose and arrange any dielectric materials close to the active capacitor. We observed some 100 pW loading at moderate excitation voltages.

  14. Wrinkling Crystallography on Curved Surfaces

    NASA Astrophysics Data System (ADS)

    Reis, Pedro; Brojan, Miha; Terwagne, Denis; Lagrange, Romain

    2014-03-01

    We present results on an experimental analysis of the morphology of wrinkling patterns on curved surfaces. Our experimental hemispherical samples are fabricated using rapid prototyping and consist of a thin-stiff shell adhered to a soft-thick substrate, both made out of silicone-based rubbers. Pressurizing an inner spherical air cavity enables compression of the samples, thereby morphing the outer thin shell from its initially smooth configuration into a wrinkled state. A variety of patterns with different morphologies can be observed depending on the combination of the sample's geometric and material properties. We focus our attention on the specific pattern mode of hexagonal-like dimples, which we characterize by analyzing their surface profile using a digital 3D scanner. Through digital image processing, we skeletonize these patterns by identifying both the location of the ridges and determining the positions of the dimples. We give emphasis to the effect of curvature on the morphology and topology of these wrinkled patterns and focus on the tiling of the wrinkling units and their statistics of defects. Our results are contrasted with other crystalline planar and curved systems.

  15. Ambient molecular imaging and depth profiling of live tissue by infrared laser ablation electrospray ionization mass spectrometry.

    PubMed

    Nemes, Peter; Barton, Alexis A; Li, Yue; Vertes, Akos

    2008-06-15

    Mass spectrometry in conjunction with atmospheric pressure ionization methods enables the in vivo investigation of biochemical changes with high specificity and sensitivity. Laser ablation electrospray ionization (LAESI) is a recently introduced ambient ionization method suited for the analysis of biological samples with sufficient water content. With LAESI mass spectrometric analysis of chimeric Aphelandra squarrosa leaf tissue, we identify the metabolites characteristic for the green and yellow sectors of variegation. Significant parts of the related biosynthetic pathways (e.g., kaempferol biosynthesis) are ascertained from the detected metabolites and metabolomic databases. Scanning electron microscopy of the ablated areas indicates the feasibility of both two-dimensional imaging and depth profiling with a approximately 350 microm lateral and approximately 50 microm depth resolution. Molecular distributions of some endogenous metabolites show chemical contrast between the sectors of variegation and quantitative changes as the ablation reaches the epidermal and mesophyll layers. Our results demonstrate that LAESI mass spectrometry opens a new way for ambient molecular imaging and depth profiling of metabolites in biological tissues and live organisms.

  16. Differentiation of oral bacteria in in vitro cultures and human saliva by secondary electrospray ionization - mass spectrometry

    NASA Astrophysics Data System (ADS)

    Bregy, Lukas; Müggler, Annick R.; Martinez-Lozano Sinues, Pablo; García-Gómez, Diego; Suter, Yannick; Belibasakis, Georgios N.; Kohler, Malcolm; Schmidlin, Patrick R.; Zenobi, Renato

    2015-10-01

    The detection of bacterial-specific volatile metabolites may be a valuable tool to predict infection. Here we applied a real-time mass spectrometric technique to investigate differences in volatile metabolic profiles of oral bacteria that cause periodontitis. We coupled a secondary electrospray ionization (SESI) source to a commercial high-resolution mass spectrometer to interrogate the headspace from bacterial cultures and human saliva. We identified 120 potential markers characteristic for periodontal pathogens Aggregatibacter actinomycetemcomitans (n = 13), Porphyromonas gingivalis (n = 70), Tanerella forsythia (n = 30) and Treponema denticola (n = 7) in in vitro cultures. In a second proof-of-principle phase, we found 18 (P. gingivalis, T. forsythia and T. denticola) of the 120 in vitro compounds in the saliva from a periodontitis patient with confirmed infection with P. gingivalis, T. forsythia and T. denticola with enhanced ion intensity compared to two healthy controls. In conclusion, this method has the ability to identify individual metabolites of microbial pathogens in a complex medium such as saliva.

  17. Differentiation of oral bacteria in in vitro cultures and human saliva by secondary electrospray ionization – mass spectrometry

    PubMed Central

    Bregy, Lukas; Müggler, Annick R.; Martinez-Lozano Sinues, Pablo; García-Gómez, Diego; Suter, Yannick; Belibasakis, Georgios N.; Kohler, Malcolm; Schmidlin, Patrick R.; Zenobi, Renato

    2015-01-01

    The detection of bacterial-specific volatile metabolites may be a valuable tool to predict infection. Here we applied a real-time mass spectrometric technique to investigate differences in volatile metabolic profiles of oral bacteria that cause periodontitis. We coupled a secondary electrospray ionization (SESI) source to a commercial high-resolution mass spectrometer to interrogate the headspace from bacterial cultures and human saliva. We identified 120 potential markers characteristic for periodontal pathogens Aggregatibacter actinomycetemcomitans (n = 13), Porphyromonas gingivalis (n = 70), Tanerella forsythia (n = 30) and Treponema denticola (n = 7) in in vitro cultures. In a second proof-of-principle phase, we found 18 (P. gingivalis, T. forsythia and T. denticola) of the 120 in vitro compounds in the saliva from a periodontitis patient with confirmed infection with P. gingivalis, T. forsythia and T. denticola with enhanced ion intensity compared to two healthy controls. In conclusion, this method has the ability to identify individual metabolites of microbial pathogens in a complex medium such as saliva. PMID:26477831

  18. Analysis of underivatized amino acids in geological samples using ion-pairing liquid chromatography and electrospray tandem mass spectrometry.

    PubMed

    Liu, De-Ling; Beegle, Luther W; Kanik, Isik

    2008-04-01

    The capability of detecting biomarkers, such as amino acids, in chemically complex field samples is essential to establishing the knowledge required to search for chemical signatures of life in future planetary explorations. However, due to the complexities of in situ investigations, it is important to establish a new analytical scheme that utilizes a minimal amount of sample preparation. This paper reports the feasibility of a novel and sensitive technique, which has been established to quantitate amino acids in terrestrial crust samples directly without derivatization using volatile ion-pairing liquid chromatography and tandem mass spectrometry equipped with an electrospray ionization source. Adequate separation of 20 underivatized amino acids was achieved on a C(18) capillary column within 26 min with nonafluoropentanoic acid (NFPA) as ion-pairing reagent. Each amino acid was identified from its retention time as well as from its characteristic parent-to-daughter ion transition. Using tandem mass spectrometry as a detection technique allows co-elution of some amino acids, as it is more specific than traditional spectrophotometric methods. In the present study, terrestrial samples collected from 3 different locations were analyzed for their water-extractable free amino acid contents, following the removal of metal and organic interferences via ion exchange procedures. This is the first time that amino acids in geological samples were directly determined quantitatively without complicated derivatization steps. Depending on the amino acid, the detection limits varied from 0.02 to 5.7 pmol with the use of a 1 microl sample injection loop.

  19. Estimation of Curve Tracing Time in Supercapacitor based PV Characterization

    NASA Astrophysics Data System (ADS)

    Basu Pal, Sudipta; Das Bhattacharya, Konika; Mukherjee, Dipankar; Paul, Debkalyan

    2017-01-01

    Smooth and noise-free characterisation of photovoltaic (PV) generators have been revisited with renewed interest in view of large size PV arrays making inroads into the urban sector of major developing countries. Such practice has recently been observed to be confronted by the use of a suitable data acquisition system and also the lack of a supporting theoretical analysis to justify the accuracy of curve tracing. However, the use of a selected bank of supercapacitors can mitigate the said problems to a large extent. Assuming a piecewise linear analysis of the V-I characteristics of a PV generator, an accurate analysis of curve plotting time has been possible. The analysis has been extended to consider the effect of equivalent series resistance of the supercapacitor leading to increased accuracy (90-95%) of curve plotting times.

  20. Shaping the learning curve: epigenetic dynamics in neural plasticity

    PubMed Central

    Bronfman, Zohar Z.; Ginsburg, Simona; Jablonka, Eva

    2014-01-01

    A key characteristic of learning and neural plasticity is state-dependent acquisition dynamics reflected by the non-linear learning curve that links increase in learning with practice. Here we propose that the manner by which epigenetic states of individual cells change during learning contributes to the shape of the neural and behavioral learning curve. We base our suggestion on recent studies showing that epigenetic mechanisms such as DNA methylation, histone acetylation, and RNA-mediated gene regulation are intimately involved in the establishment and maintenance of long-term neural plasticity, reflecting specific learning-histories and influencing future learning. Our model, which is the first to suggest a dynamic molecular account of the shape of the learning curve, leads to several testable predictions regarding the link between epigenetic dynamics at the promoter, gene-network, and neural-network levels. This perspective opens up new avenues for therapeutic interventions in neurological pathologies. PMID:25071483

  1. Curved surface effect and emission on silicon nanostructures

    NASA Astrophysics Data System (ADS)

    Huang, Wei-Qi; Yin, Jun; Zhou, Nian-Jie; Huang, Zhong-Mei; Miao, Xin-Jian; Cheng, Han-Qiong; Su, Qin; Liu, Shi-Rong; Qin, Chao-Jian

    2013-10-01

    The curved surface (CS) effect on nanosilicon plays a main role in the activation for emission and photonic manipulation. The CS effect breaks the symmetrical shape of nanosilicon on which some bonds can produce localized electron states in the band gap. The investigation in calculation and experiment demonstrates that the different curvatures can form the characteristic electron states for some special bonding on the nanosilicon surface, which are related to a series of peaks in photoluminecience (PL), such as LN, LNO, LO1, and LO2 lines in PL spectra due to Si—N, Si—NO, Si=O, and Si—O—Si bonds on curved surface, respectively. Si—Yb bond on curved surface of Si nanostructures can provide the localized states in the band gap deeply and manipulate the emission wavelength into the window of optical communication by the CS effect, which is marked as the LYb line of electroluminescence (EL) emission.

  2. Electrospray ionization in concentrated acetonitrile vapor improves the performance of mass spectrometry for proteomic analyses.

    PubMed

    Chen, Jin; Wang, Fangjun; Liu, Zheyi; Liu, Jing; Zhu, Yixin; Zhang, Yukui; Zou, Hanfa

    2017-02-03

    Suppressing the background interferences and enhancing the analytes signals are long-term goals in high performance electrospray ionization mass spectrometry (ESI-MS) analyses. We observed that performing electrospray in the presence of a concentrated acetonitrile atmosphere suppresses background interferences and enhances peptide signals. An enclosed nanoESI source was utilized to provide a stable atmosphere of concentrated acetonitrile vapor for high performance ESI-MS analyses. The median MS signal intensity increased by 5 times for a set of 23 BSA tryptic peptides in direct ESI-MS analysis. Further, the number of reproducibly and precisely quantified peptides could be improved 67% in six replicate label-free quantitative proteome analyses by this strategy.

  3. Determination of macrolide antibiotics in chicken tissues by liquid chromatography-electrospray mass spectrometry

    NASA Astrophysics Data System (ADS)

    Salikin, Jamilah; Abdullah, Aminah

    2013-11-01

    A methodusingliquid chromatography-electrospray mass spectrometry (LC-(ESI)MS) for the simultaneous determination of three macrolides (tylosin, spiramycin and tilmicosin) in poultry muscle has been developed. The drugs were extracted with EDTA McIlvaine buffer, filter through celite 545 and the extracts were cleaned up by SPE Oasis HLB cartridge. Separation was carried out in end-capped silica-based C18 column and mobile phases containing trifluoroacetic acid-acetonitrile with a binary gradient system at a flow rate 0.5 ml/min. Detection was performed by single mass spectrometry with electrospray ionization in the positive mode. Several parameters affecting the mass spectra were studied. Chicken samples from the market were analyzed to check the residue of macrolide antibiotics.

  4. Development and Applications of Liquid Sample Desorption Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Zheng, Qiuling; Chen, Hao

    2016-06-01

    Desorption electrospray ionization mass spectrometry (DESI-MS) is a recent advance in the field of analytical chemistry. This review surveys the development of liquid sample DESI-MS (LS-DESI-MS), a variant form of DESI-MS that focuses on fast analysis of liquid samples, and its novel analy-tical applications in bioanalysis, proteomics, and reaction kinetics. Due to the capability of directly ionizing liquid samples, liquid sample DESI (LS-DESI) has been successfully used to couple MS with various analytical techniques, such as microfluidics, microextraction, electrochemistry, and chromatography. This review also covers these hyphenated techniques. In addition, several closely related ionization methods, including transmission mode DESI, thermally assisted DESI, and continuous flow-extractive DESI, are briefly discussed. The capabilities of LS-DESI extend and/or complement the utilities of traditional DESI and electrospray ionization and will find extensive and valuable analytical application in the future.

  5. Analysis of submicron-sized niflumic acid crystals prepared by electrospray crystallization.

    PubMed

    Ambrus, Rita; Radacsi, Norbert; Szunyogh, Tímea; van der Heijden, Antoine E D M; Ter Horst, Joop H; Szabó-Révész, Piroska

    2013-03-25

    Interest in submicron-sized drug particles has emerged from both laboratory and industrial perspectives in the last decade. Production of crystals in the nano size scale offers a novel way to particles for drug formulation solving formulation problems of drugs with low solubility in class II of the Biopharmaceutical Classification System. In this work niflumic acid nanoparticles with a size range of 200-800nm were produced by the novel crystallization method, electrospray crystallization. Their properties were compared to those from evaporative and anti-solvent crystallizations, using the same organic solvent, acetone. There is a remarkable difference in the product crystal size depending on the applied methods. The size and morphology were analyzed by scanning electron microscopy and laser diffraction. The structure of the samples was investigated using differential scanning calorimetry, Fourier-transformed infrared spectroscopy and X-ray powder diffraction. The particles produced using electrospray crystallization process were probably changing from amorphous to crystalline state after the procedure.

  6. System and method for liquid extraction electrospray-assisted sample transfer to solution for chemical analysis

    DOEpatents

    Kertesz, Vilmos; Van Berkel, Gary J.

    2016-07-12

    A system for sampling a surface includes a surface sampling probe comprising a solvent liquid supply conduit and a distal end, and a sample collector for suspending a sample collection liquid adjacent to the distal end of the probe. A first electrode provides a first voltage to solvent liquid at the distal end of the probe. The first voltage produces a field sufficient to generate electrospray plume at the distal end of the probe. A second electrode provides a second voltage and is positioned to produce a plume-directing field sufficient to direct the electrospray droplets and ions to the suspended sample collection liquid. The second voltage is less than the first voltage in absolute value. A voltage supply system supplies the voltages to the first electrode and the second electrode. The first electrode can apply the first voltage directly to the solvent liquid. A method for sampling for a surface is also disclosed.

  7. Multiresidue analysis of seven anticoagulant rodenticides by high-performance liquid chromatography/electrospray/mass spectrometry.

    PubMed

    Marek, LeEtta J; Koskinen, William C

    2007-02-07

    Mice and rat populations are commonly controlled by two classes of rodenticide anticoagulants, coumarins and indandiones. However, poisoning of nontarget animals also often occurs. For cases such as these, a rapid, multiresidue method, which provides positive confirmation for both classes of anticoagulant rodenticides, is needed by diagnostic laboratories. A method was developed for the determination of seven anticoagulant rodenticides, coumafuryl, pindone, warfarin, diphacinone, chlorophacinone, bromadiolone, and brodifacoum, in diverse matrices, animal feed, cooked beef, and fruit-flavored beverages using high-performance liquid chromatography/electrospray/mass spectrometry. Detection was by MS/MS with electrospray ionization in negative mode. Confirmation was by retention time, m/z of molecular ion, and two parent-daughter transitions. Recoveries from selected the matrices ranged from 61 to 117%. Limits of quantitation were as low as 1.5-4.5 ng g-1. The developed method was rapid and provided the simultaneous confirmation and quantification of the seven anticoagulant rodenticides.

  8. Compound coverage enhancement of electrospray ionization mass spectrometry through the addition of a homemade needle.

    PubMed

    Xiao, Shun; Qian, Shuai; Wang, Yi; Zhang, Yufeng; Cheng, Yiyu

    2013-03-21

    The response of many previously low-detectable or undetectable compounds in electrospray ionization mass spectrometry (ESI-MS) has been enhanced by the addition of a simple, homemade needle into the traditional ESI interface. The needle located between the ESI emitter and the ion sweep cone (inlet of the detector) would ionize those neutral gaseous compounds, formed during electrospray, by a corona discharge process. The mobile phases, ESI parameters and positions of the needle were investigated and optimized. Several groups of compounds and herbal extracts were tested using the homemade set-up. Both the results of the flow injection and the hyphenated MS analyses showed significant enhancement effects of our homemade needle. The advantages of the proposed method include low cost, simplicity and practicality.

  9. Self-aligning subatmospheric hybrid liquid junction electrospray interface for capillary electrophoresis.

    PubMed

    Krenkova, Jana; Kleparnik, Karel; Grym, Jakub; Luksch, Jaroslav; Foret, Frantisek

    2016-02-01

    We report a construction of a self-aligning subatmospheric hybrid liquid junction electrospray interface for CE eliminating the need for manual adjustment by guiding the capillaries in a microfabricated liquid junction glass chip at a defined angle. Both the ESI and separation capillaries are inserted into the microfabricated part until their ends touch. The distance between the capillary openings is defined by the angle between the capillaries. The microfabricated part contains channels for placement of the capillaries and connection of the external electrode reservoirs. It was fabricated using standard photolithographic/wet chemical etching techniques followed by thermal bonding. The liquid junction is connected to a subatmospheric electrospray chamber inducing the flow inside the ESI needle and helping the ion transport via aerodynamic focusing.

  10. Encapsulation of folic acid in food hydrocolloids through nanospray drying and electrospraying for nutraceutical applications.

    PubMed

    Pérez-Masiá, Rocío; López-Nicolás, Rubén; Periago, Maria Jesús; Ros, Gaspar; Lagaron, Jose M; López-Rubio, Amparo

    2015-02-01

    In this work, two different technologies (electrospraying and nanospray drying) were evaluated for the encapsulation of folic acid using both a whey protein concentrate (WPC) matrix and a commercial resistant starch. The morphology of the capsules, molecular organization of the matrices upon encapsulation, encapsulation efficiency, and stability of the folic acid within the capsules under different storage conditions and upon thermal exposure were studied. Results showed that spherical nano-, submicro- and microcapsules were obtained through both techniques, although electrospraying led to smaller capsule sizes and to an enhanced control over their size distribution. Greater encapsulation efficiency was observed using WPC as encapsulating matrix, probably related to interactions between the protein and folic acid which favoured the incorporation of the bioactive. The best results in terms of bioactive stabilization in the different conditions assayed were also obtained for the WPC capsules, although both materials and encapsulation techniques led to improved folic acid stability, especially under dry conditions.

  11. Multidimensional detection of explosives and explosive signatures via laser electrospray mass spectrometry

    NASA Astrophysics Data System (ADS)

    Brady, John J.; Flanigan, Paul M., IV; Perez, Johnny J.; Judge, Elizabeth J.; Levis, Robert J.

    2012-06-01

    Nitro- and inorganic-based energetic material is vaporized at atmospheric pressure using nonresonant, 70 femtosecond laser pulses prior to electrospray post-ionization and transfer into a time-of-flight mass spectrometer for mass analysis. Measurements of a nitro-based energetic molecule, cyclotrimethylenetrinitramine (RDX), adsorbed on metal and dielectric surfaces indicate nonresonant vaporization of intact molecules, demonstrating the universality of laser electrospray mass spectrometry (LEMS) technique for explosives. In addition, RDX is analyzed at a distance of 2 meters to demonstrate the remote detection capability of LEMS. Finally, the analysis and multivariate statistical classification of inorganic-based explosives containing ammonium nitrate, chlorate, perchlorate, black powder, and an organic-based explosive is presented, further expanding the capabilities of the LEMS technique for detection of energetic materials.

  12. Design and performance of an electrospray ion source for magnetic-sector mass spectrometers

    NASA Astrophysics Data System (ADS)

    Belov, Mikhail E.; Colburn, Alex W.; Derrick, Peter J.

    1998-03-01

    An electrospray ion (ESI) source capable of operating at accelerating potentials of up to 11 kV has been designed and fabricated. The ESI source has been shown to deliver ion beams with a total current up to 20 pA and an emittance of 2-3 mm mrad in analysis of the peptide gramicidin S (molecular mass 1140.7 Da) and the protein bovine insulin B chain (molecular mass 3495.9 Da). Coupled to a two-sector tandem mass spectrometer, the ESI source produced efficiently the multiply charged ions of proteins, such as bovine ubiquitin (molecular mass 8564.8 Da) and cytochrome c (molecular mass 12327 Da). The high ion currents and high kinetic energies of the electrospray ions (up to 200 keV) characterize this ESI source as a powerful tool to be used in structural analysis of macromolecules by collision-induced dissociation.

  13. Electrospray mass spectral fragmentation study of N,N'-disubstituted imidazolium ionic liquids.

    PubMed

    Lesimple, Alain; Mamer, Orval; Miao, Weishi; Chan, Tak Hang

    2006-01-01

    The tandem positive electrospray mass spectrometry (ESMS(n)) fragmentation of ionic liquids incorporating the 1-methyl-imidazolium ring substituted on N(II) with an alkyl chain functionalized with an alcohol, carboxylic acid, or an iodobenzyl or iodobenzoyl ester is presented for the first time. The influence of chain length and function is studied. Esterified structures led to intense CID fragments lacking the imidazolium ring allowing full characterization of the ester moiety. Fragment ion compositions for this interesting and newly important class of compounds are established through accurate mass data and deuterium labeling. The presence of the cationic ring system produces intense even electron molecular cations in electrospray that undergo multiple stages of CID to yield fragments which often are radical cations. Unusual losses of methyl and hydrogen radicals are frequently noted.

  14. Biomolecular analysis and cancer diagnostics by negative mode probe electrospray ionization.

    PubMed

    Mandal, Mridul Kanti; Saha, Subhrakanti; Yoshimura, Kentaro; Shida, Yasuo; Takeda, Sen; Nonami, Hiroshi; Hiraoka, Kenzo

    2013-03-21

    We have examined several combinations of solvents and probes with the aim of optimizing the ionization conditions for biomolecules e.g., proteins, peptides and lipids by negative mode probe electrospray ionization mass spectrometry (PESI-MS). With the data presented in this study, negative-mode PESI-MS can be considered as a potential tool for biomolecular analysis and cancer diagnostics because of its simplicity in instrumental configuration. A sharper sampling probe was found to be better for obtaining high quality mass spectra because it can generate stable electrospray without the occurrence of gas breakdown. Although the best conditions may depend on each sample, aqueous organic solvent solutions, especially isopropanol-H(2)O (1/1) with a pH of ≥7, are shown to be preferable for negative-mode PESI-MS, which was successfully applied to colon cancer diagnosis.

  15. Rapid differentiation of refined fuels using negative electrospray ionization/mass spectrometry

    USGS Publications Warehouse

    Rostad, C.E.; Hostettler, F.D.

    2005-01-01

    Negative electrospray ionization/MS enabled rapid, specific, and selective screening for unique polar components at parts per million concentrations in commercial hydrocarbon products without extensive sample preparation, separation, chromatography, or quantitation. Commercial fuel types were analyzed with this method, including kerosene, jet fuel, white gas, charcoal lighter fluid, on-road and off-road diesel fuels, and various grades and brands of gasolines. The different types of fuels produced unique and relatively simple spectra. These analyses were then applied to hydrocarbon samples from a large, long-term fuel spill. Although the alkane, isoprenoid, and alkylcyclohexane portions began to biodegrade or weather, the polar components in these samples remained relatively unchanged. The type of fuel involved was readily identified by negative electrospray ionization/MS. This is an abstract of a paper presented at the 230th ACS National Meeting (Washington, DC 8/28/2005-9/1/2005).

  16. Direct Characterization of Bulk Samples by Internal Extractive Electrospray Ionization Mass Spectrometry

    PubMed Central

    Zhang, Hua; Gu, Haiwei; Yan, Feiyan; Wang, Nannan; Wei, Yiping; Xu, Jianjun; Chen, Huanwen

    2013-01-01

    A straight-forward analytical strategy called internal extractive electrospray ionization mass spectrometry (iEESI-MS), which combines solvent extraction of chemicals inside a bulk sample with in situ electrospray ionization mass spectrometry, has been established to directly characterize the interior of a bulk sample with molecular specificity. The method allows both qualitative and quantitative analysis of analytes distributed in a 3-dimensional volume (e.g., 1 ~ 100 mm3) of various synthetic and biological matrices (e.g., chewing gum, leaves, fruits, roots, pork, lung tissues) without either mashing the sample or matrix separation. Using different extraction solvents, online chromatographic separation of chemicals inside the sample volume was observed during iEESI-MS analysis. The presented method is featured by the high speed of analysis, high sensitivity, low sample consumption and minimal sample preparation and/or degradation, offering unique possibilities for advanced applications in plant science, clinical diagnosis, catalyst studies, and materials science. PMID:23970067

  17. Sensitive detection of drug vapors using an ion funnel interface for secondary electrospray ionization mass spectrometry.

    PubMed

    Meier, Lukas; Berchtold, Christian; Schmid, Stefan; Zenobi, Renato

    2012-05-01

    In this study, we use an ion funnel (IF) at ambient pressure to enhance the sensitivity of secondary electrospray ionization (SESI). Atenolol, salbutamol and cocaine as test compounds are delivered to the SESI interface in the gas phase and are charged with three nano electrosprays. In our experiments, we show that the compounds can be detected at concentrations in the low pptv range, which is an increase of two orders of magnitude compared with the results without the IF. With a standard SESI interface, the compounds could not be detected at all. With the use of the SESI IF interface for the headspace analysis of bananas and limes, we can detect many more compounds and at higher intensities than with a standard SESI interface.

  18. The onset of electrospray: the universal scaling laws of the first ejection

    PubMed Central

    Gañán-Calvo, A. M.; López-Herrera, J. M.; Rebollo-Muñoz, N.; Montanero, J. M.

    2016-01-01

    The disintegration of liquid drops with low electrical conductivity and subject to an electric field is investigated both theoretically and experimentally. This disintegration takes place through the development of a conical cusp that eventually ejects an ultrathin liquid ligament. A first tiny drop is emitted from the end of this ligament. Due to its exceptionally small size and large electric charge per unit volume, that drop has been the object of relevant recent studies. In this paper, universal scaling laws for the diameter and electric charge of the first issued droplet are proposed and validated both numerically and experimentally. Our analysis shows how charge relaxation is the mechanism that differentiates the onset of electrospray, including the first droplet ejection, from the classical steady cone-jet mode. In this way, our study identifies when and where charge relaxation and electrokinetic phenomena come into play in electrospray, a subject of live controversy in the field. PMID:27581554

  19. The onset of electrospray: the universal scaling laws of the first ejection.

    PubMed

    Gañán-Calvo, A M; López-Herrera, J M; Rebollo-Muñoz, N; Montanero, J M

    2016-09-01

    The disintegration of liquid drops with low electrical conductivity and subject to an electric field is investigated both theoretically and experimentally. This disintegration takes place through the development of a conical cusp that eventually ejects an ultrathin liquid ligament. A first tiny drop is emitted from the end of this ligament. Due to its exceptionally small size and large electric charge per unit volume, that drop has been the object of relevant recent studies. In this paper, universal scaling laws for the diameter and electric charge of the first issued droplet are proposed and validated both numerically and experimentally. Our analysis shows how charge relaxation is the mechanism that differentiates the onset of electrospray, including the first droplet ejection, from the classical steady cone-jet mode. In this way, our study identifies when and where charge relaxation and electrokinetic phenomena come into play in electrospray, a subject of live controversy in the field.

  20. Pulsed voltage electrospray ion source and method for preventing analyte electrolysis

    DOEpatents

    Kertesz, Vilmos [Knoxville, TN; Van Berkel, Gary [Clinton, TN

    2011-12-27

    An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

  1. Protein encapsulated core-shell structured particles prepared by coaxial electrospraying: investigation on material and processing variables.

    PubMed

    Zamani, Maedeh; Prabhakaran, Molamma P; Thian, Eng San; Ramakrishna, Seeram

    2014-10-01

    Biodegradable polymeric particles have been extensively investigated for controlled drug delivery of various therapeutic agents. 'Coaxial' electrospraying was successfully employed in this study, to fabricate core-shell PLGA particles containing bovine serum albumin (BSA) as the model protein, and the results were also compared to particles prepared by 'emulsion' electrospraying. Two different molecular weights of PLGA were employed to encapsulate the protein. Solution properties and processing parameters were found to influence the morphology of the core-shell particles. Depending on the type of solvent used to dissolve the polymer as well as the polymer concentration and molecular weight, the mean diameter of the particles varied between 3.0 to 5.5 μm. Fluorescence microscopic analysis of the electrosprayed particles using FITC-conjugated BSA demonstrated the core-shell structure of the developed particles. The encapsulation efficiency and release behavior of BSA was influenced by shell:core feeding ratio, protein concentration, and the electrospraying method. The encapsulation efficiency of BSA within the core-shell particles of high and low molecular weight PLGA was found 15.7% and 25.1% higher than the emulsion electrosprayed particles, respectively. Moreover, the total amount of BSA released from low molecular weight PLGA particles was significantly higher than high molecular weight PLGA particles within 43 days of release studies, with negligible effect on encapsulation efficiency. The technique of coaxial electrospraying has high potential for encapsulation of susceptible protein-based therapeutic agents such as growth factors for multiple drug delivery applications.

  2. Bio-electrospraying the nematode Caenorhabditis elegans: studying whole-genome transcriptional responses and key life cycle parameters

    PubMed Central

    Mongkoldhumrongkul, Napachanok; Swain, Suresh C.; Jayasinghe, Suwan N.; Stürzenbaum, Stephen

    2010-01-01

    Bio-electrospray, the direct jet-based cell handling approach, is able to handle a wide range of cells (spanning immortalized, primary to stem cells). Studies at the genomic, genetic and the physiological levels have shown that, post-treatment, cellular integrity is unperturbed and a high percentage (more than 70%, compared with control) of cells remain viable. Although, these results are impressive, it may be argued that cell-based systems are oversimplistic. Therefore, it is important to evaluate the bio-electrospray technology using sensitive and dynamically developing multi-cellular organisms that share, at least some, similarities with multi-cell microenviorments encountered with tissues and organs. This study addressed this issue by using a well-characterized model organism, the non-parasitic nematode Caenorhabditis elegans. Nematode cultures were subjected to bio-electrospraying and compared with positive (heat shock) and negative controls (appropriate laboratory culture controls). Overall, bio-electrospraying did not modulate the reproductive output or induce significant changes in in vivo stress-responsive biomarkers (heat shock proteins). Likewise, whole-genome transcriptomics could not identify any biological processes, cellular components or molecular functions (gene ontology terms) that were significantly enriched in response to bio-electrospraying. This demonstrates that bio-electrosprays can be safely applied directly to nematodes and underlines its potential future use in the creation of multi-cellular environments within clinical applications. PMID:19776148

  3. The influence of electrospray deposition in matrix-assisted laser desorption/ionization mass spectrometry sample preparation for synthetic polymers.

    PubMed

    Wetzel, Stephanie J; Guttman, Charles M; Flynn, Kathleen M

    2004-01-01

    Although electrospray sample deposition in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) sample preparation increases the repeatability of both the MALDI signal intensity and the measured molecular mass distribution (MMD), the electrospray sample deposition method may influence the apparent MMD of a synthetic polymer. The MMDs of three polymers of differing thermal stability, polystyrene (PS), poly(ethylene glycol) (PEG), and poly(propylene glycol) (PPG), were studied by MALDI time-of-flight (TOF) MS as the electrospray deposition voltage was varied. The MMDs obtained using the electrospray deposition method were compared with those obtained for hand-spotted samples. No change was observed in the measured polymer MMD when the electrospray deposition voltage was varied in the analysis of PS, but those of PEG and PPG changed at higher electrospray voltages due to increased ion fragmentation. It was also shown that the fragmentation in the hand-spotted samples is dependent on the matrix used in sample preparation.

  4. Protein-based emulsion electrosprayed micro- and submicroparticles for the encapsulation and stabilization of thermosensitive hydrophobic bioactives.

    PubMed

    Gómez-Mascaraque, Laura G; López-Rubio, Amparo

    2016-03-01

    This work shows the potential of emulsion electrospraying of proteins using food-grade emulsions for the microencapsulation and enhanced protection of a model thermosensitive hydrophobic bioactive. Specifically, gelatin, a whey protein concentrate (WPC) and a soy protein isolate (SPI) were compared as emulsion stabilizers and wall matrices for encapsulation of α-linolenic acid. In a preliminary stage, soy bean oil was used as the hydrophobic component for the implementation of the emulsion electrospraying process, investigating the effect of protein type and emulsion protocol used (i.e. with or without ultrasound treatment) on colloidal stability. This oil was then substituted by the ω-3 fatty acid and the emulsions were processed by electrospraying and spray-drying, comparing both techniques. While the latter resulted in massive bioactive degradation, electrospraying proved to be a suitable alternative, achieving microencapsulation efficiencies (MEE) of up to ∼70%. Although gelatin yielded low MEEs due to the need of employing acetic acid for its processing by electrospraying, SPI and WPC achieved MEEs over 60% for the non-sonicated emulsions. Moreover, the degradation of α-linolenic acid at 80°C was significantly delayed when encapsulated within both matrices. Whilst less than an 8% of its alkene groups were detected after 27h of thermal treatment for free α-linolenic acid, up to 43% and 67% still remained intact within the electrosprayed SPI and WPC capsules, respectively.

  5. Generation of gas-phase zirconium fluoroanions by electrospray of an ionic liquid

    SciTech Connect

    Gary S. Groenewold; James E. Delmore; Michael T. Benson; Tetsuya Tsuda; Rika Hagiwara

    2014-06-01

    RATIONALE: When measuring extremely wide isotope ratios (= 1 x 109) accelerator mass spectrometry (AMS) is the instrument of choice, however it requires an anion for injection into the tandem accelerator. Since many elements do not have positive electronegativities they do not form stable negative atomic ions, and hence are not compatible for isotope ratio measurement using AMS. Thus new approaches for forming anions are sought; fluoroanions are particularly attractive because fluorine is monoisotopic, and thus will not have overlapping isobars with the isotope of interest. METHODS: An approach is described for making zirconium fluoroanions using the fluorinating ionic liquid (IL) 1-ethyl-3-methylimidazolium fluorohydrogenate, which was used to generate abundant [ZrF5-] using electrospray ionization. The IL was dissolved in acetonitrile, combined with a dilute solution of either Zr4+ or ZrO2+, and then electrosprayed. Mass analysis and collision induced dissociation were conducted using a time-of-flight mass spectrometer. Cluster structures were predicted using density functional theory calculations. RESULTS: The fluorohydrogenate IL solutions generated abundant [ZrF5-] starting from solutions of both Zr4+ and ZrO2+. The mass spectra also contained IL-bearing cluster ions, whose compositions indicated the presence of [ZrF6]2- in solution, a conclusion supported by the structural calculations. Rinsing out the zirconium-IL solution with acetonitrile decreased the IL clusters, but enhanced [ZrF5]-, which was sorbed by the polymeric electrospray supply capillary, and then released upon rinsing. This reduced the ion background in the mass spectrum. CONCLUSIONS: The fluorohydrogenate-IL solutions are a facile way to form zirconium fluoroanions in the gas phase using electrospray. The approach has potential as a source of fluoroanions for injection into an AMS, which would enable high-sensitivity measurement of minor zirconium isotopes, and benefits from the absence of

  6. Catalyst layers for proton exchange membrane fuel cells prepared by electrospray deposition on Nafion membrane

    NASA Astrophysics Data System (ADS)

    Chaparro, A. M.; Ferreira-Aparicio, P.; Folgado, M. A.; Martín, A. J.; Daza, L.

    The electrospray deposition method has been used for preparation of catalyst layers for proton exchange membrane fuel cells (PEMFC) on Nafion membrane. Deposition of Pt/C + ionomer suspensions on Nafion 212 gives rise to layers with a globular morphology, in contrast with the dendritic growth observed for the same layers when deposited on the gas diffusion layer, GDL (microporous carbon black layer on carbon cloth) or on metallic Al foils. Such a change is discussed in the light of the influence of the Nafion substrate on the electrospray deposition process. Nafion, which is a proton conductor and electronic insulator, gives rise to the discharge of particles through proton release and transport towards the counter electrode, compared with the direct electron transfer that takes place when depositing on an electronic conductor. There is also a change in the electric field distribution in the needle to counter-electrode gap due to the presence of Nafion, which may alter conditions for the electrospray effect. If discharging of particles is slow enough, for instances with a low membrane protonic conductivity, the Nafion substrate may be charged positively yielding a change in the electric field profile and, with it, in the properties of the film. Single cell characterization is carried out with Nafion 212 membranes catalyzed by electrospray on the cathode side. It is shown that the internal resistance of the cell decreases with on-membrane deposited cathodic catalyst layers, with respect to the same layers deposited on GDL, giving rise to a considerable improvement in cell performance. The lower internal resistance is due to higher proton conductivity at the catalyst layer-membrane interface resulting from on-membrane deposition. On the other hand, electroactive area and catalyst utilization appear little modified by on-membrane deposition, compared with on-GDL deposition.

  7. Accurate Mass Assignment of Native Protein Complexes Detected by Electrospray Mass Spectrometry

    PubMed Central

    Liepold, Lars O.; Oltrogge, Luke M.; Suci, Peter; Douglas, Trevor; Young, Mark J.

    2009-01-01

    Correct charge state assignment is crucial to assigning an accurate mass to supramolecular complexes analyzed by electrospray mass spectrometry. Conventional charge state assignment techniques fall short of reliably and unambiguously predicting the correct charge state for many supramolecular complexes. We provide an explanation of the shortcomings of the conventional techniques and have developed a robust charge state assignment method that is applicable to all spectra. PMID:19103497

  8. Speciation of chromium and manganese using pneumatically assisted electrospray mass spectrometry

    SciTech Connect

    Gwizdala, III, Albin B.

    1996-10-17

    It is not an exaggeration to say that much of chemistry involves ions in solution. A technique which allows for ions to be transferred from solution into the gas phase and subsequently analyzed by mass spectrometric detection would be of importance. If structural information, representative of the solution chemistry could be gained from these gas-phase ions, this would also be important. Electrospray mass spectrometry (ES-MS) is such a technique.

  9. The Aggregate Demand Curve: A Reply.

    ERIC Educational Resources Information Center

    Hansen, Richard B.; And Others

    1987-01-01

    Responds to claims about the instructional value of the downward-sloping aggregate demand curve in teaching principles of macroeconomics. Examines the effects of interest-rates and the role of money on demand curves. Concludes by arguing against the use of downward-sloping aggregate demand curves in textbooks. (RKM)

  10. Cubic spline functions for curve fitting

    NASA Technical Reports Server (NTRS)

    Young, J. D.

    1972-01-01

    FORTRAN cubic spline routine mathematically fits curve through given ordered set of points so that fitted curve nearly approximates curve generated by passing infinite thin spline through set of points. Generalized formulation includes trigonometric, hyperbolic, and damped cubic spline fits of third order.

  11. Identification of oxidation products of solanesol produced during air sampling for tobacco smoke by electrospray mass spectrometry and HPLC.

    PubMed

    Tucker, Samuel P; Pretty, Jack R

    2005-10-01

    Solanesol, a 45-carbon, trisesquiterpenoid alcohol found in tobacco leaves and tobacco smoke, has been used as a quantitative marker for tobacco smoke for years. However, solanesol appears to be unreliable as a quantitative marker for tobacco smoke during environmental air sampling because it can be degraded substantially when present as a component of tobacco smoke and by as much as 100% when present as pure solanesol on fortified filters during air sampling. Since there is strong evidence that ozone is the agent responsible for the degradation, solanesol appears to be unreliable as a quantitative marker during indoor air sampling when indoor levels of ozone are greater than about 15 ppb. The degree of loss of pure solanesol is directly proportional to the concentration of ozone and the length of the sampling period and depends on the type of 37 mm membrane filter used for air sampling (PTFE or quartz fiber). While the degree of loss of solanesol is inversely proportional to the relative humidity of the air at a sampling rate of 1.7 L min(-1), the degree of loss is virtually independent of relative humidity at a lower sampling rate; i.e., 0.25 L min(-1). A curve of loss of solanesol on a filter versus concentration of ozone from an ozone generator is virtually identical to a curve segment based on atmospheric ozone under the same conditions of air sampling. Oxidation of solanesol by ozone to approximately 25 to 60% completion produces at least three series of products for a total of at least 26 compounds: (1) isoprenoid acetones, (2)omega-hydroxyisoprenoid acetaldehydes, and (3) isoprenoid oxoaldehydes. All products in each series were tentatively identified as their derivatives with 2-(p-aminophenyl)ethanol (APE) by electrospray mass spectrometry (ES-MS). Ten ozonation products were detected as their 2,4-dinitrophenylhydrazine derivatives by HPLC at 360 nm: 4-oxopentanal and nine isoprenoid acetones (acetone, 6-methyl-5-hepten-2-one, geranylacetone

  12. Coupling of gas chromatography and electrospray ionization high resolution mass spectrometry for the analysis of anabolic steroids as trimethylsilyl derivatives in human urine.

    PubMed

    Cha, Eunju; Jeong, Eun Sook; Cha, Sangwon; Lee, Jaeick

    2017-04-29

    In this study, gas chromatography (GC) was interfaced with high resolution mass spectrometry (HRMS) with electrospray ionization source (ESI) and the relevant parameters were investigated to enhance the ionization efficiency. In GC-ESI, the distances (x-, y- and z) and angle between the ESI needle, GC capillary column and MS orifice were set to 7 (x-distance), 4 (y-distance), and 1 mm (z-distance). The ESI spray solvent, acid modifier and nebulizer gas flow were methanol, 0.1% formic acid and 5 arbitrary units, respectively. Based on these results, analytical conditions for GC-ESI/HRMS were established. In particular, the results of spray solvent flow indicated a concentration-dependent mechanism (peak dilution effect), and other parameters also greatly influenced the ionization performance. The developed GC-ESI/HRMS was then applied to the analysis of anabolic steroids as trimethylsilyl (TMS) derivatives in human urine to demonstrate its application. The ionization profiles of TMS-derivatized steroids were investigated and compared with those of underivatized steroids obtained from gas chromatography-electrospray ionization/mass spectrometry (GC-ESI/MS) and liquid chromatography-electrospray ionization/mass spectrometry (LC-ESI/MS). The steroids exhibited ionization profiles based on their structural characteristics, regardless of the analyte phase or derivatization. Groups I and II with conjugated or unconjugated keto functional groups at C3 generated the [M+H](+) and [M+H-TMS](+) ions, respectively. On the other hand, Groups III and IV gave rise to the characteristic fragment ions [M+H-TMS-H2O](+) and [M+H-2TMS-H2O](+), corresponding to loss of a neutral TMS·H2O moiety from the protonated molecular ion by in-source dissociation. To the best of our knowledge, this is the first study to successfully ionize and analyze steroids as TMS derivatives using ESI coupled with GC. The present system has enabled the ionization of TMS derivatives under ESI conditions and

  13. Origin of supercharging in electrospray ionization of noncovalent complexes from aqueous solution.

    PubMed

    Sterling, Harry J; Williams, Evan R

    2009-10-01

    The use of m-nitrobenzyl alcohol (m-NBA) to enhance charging of noncovalent complexes formed by electrospray ionization from aqueous solutions was investigated. Addition of up to 1% m-NBA can result in a significant increase in the average charging of complexes, ranging from approximately 13% for the homo-heptamer of NtrC4-RC (317 kDa; maximum charge state increases from 42+ to 44+) to approximately 49% for myoglobin (17.6 kDa; maximum charge state increases from 9+ to 16+). Charge state distributions of larger complexes obtained from heated solutions to which no m-NBA was added are remarkably similar to those containing small amounts of m-NBA. Dissociation of the complexes through identical channels both upon addition of higher concentrations of m-NBA and heating is observed. These results indicate that the enhanced charging upon addition of m-NBA to aqueous electrospray solutions is a result of droplet heating owing to the high boiling point of m-NBA, which results in a change in the higher-order structure and/or dissociation of the complexes. For monomeric proteins and small complexes, the enhancement of charging is lower for heated aqueous solutions than from solutions with m-NBA because rapid folding of proteins from heated solutions that do not contain m-NBA can occur after the electrospray droplet is formed and is evaporatively cooled.

  14. Integrated Microfluidic Device for Automated Single Cell Analysis using Electrophoretic Separation and Electrospray Ionization Mass Spectrometry

    PubMed Central

    Mellors, J. Scott; Jorabchi, Kaveh; Smith, Lloyd M.; Ramsey, J. Michael

    2010-01-01

    A microfabricated fluidic device was developed for the automated real-time analysis of individual cells using capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS). The microfluidic structure incorporates a means for rapid lysis of single cells within a free solution electrophoresis channel where cellular constituents were separated and an integrated electrospray emitter for ionization of separated components. The eluent was characterized using mass spectrometry. Human erythrocytes were used as a model system for this study. In this monolithically integrated device, cell lysis occurs at a channel intersection using a combination of rapid buffer exchange and an increase in electric field strength. An electroosmotic pump is incorporated at the end of the electrophoretic separation channel to direct eluent to the integrated electrospray emitter. The dissociated heme group and the α and β subunits of hemoglobin from individual erythrocytes were detected as cells continuously flowed through the device. The average analysis throughput was approximately 12 cells per minute demonstrating the potential of this method for high-throughput single cell analysis. PMID:20058879

  15. Experimental design and instability analysis of coaxial electrospray process for microencapsulation of drugs and imaging agents.

    PubMed

    Si, Ting; Zhang, Leilei; Li, Guangbin; Roberts, Cynthia J; Yin, Xiezhen; Xu, Ronald

    2013-07-01

    Recent developments in multimodal imaging and image-guided therapy requires multilayered microparticles that encapsulate several imaging and therapeutic agents in the same carrier. However, commonly used microencapsulation processes have multiple limitations such as low encapsulation efficiency and loss of bioactivity for the encapsulated biological cargos. To overcome these limitations, we have carried out both experimental and theoretical studies on coaxial electrospray of multilayered microparticles. On the experimental side, an improved coaxial electrospray setup has been developed. A customized coaxial needle assembly combined with two ring electrodes has been used to enhance the stability of the cone and widen the process parameter range of the stable cone-jet mode. With this assembly, we have obtained poly(lactide-co-glycolide) microparticles with fine morphology and uniform size distribution. On the theoretical side, an instability analysis of the coaxial electrified jet has been performed based on the experimental parameters. The effects of process parameters on the formation of different unstable modes have been studied. The reported experimental and theoretical research represents a significant step toward quantitative control and optimization of the coaxial electrospray process for microencapsulation of multiple drugs and imaging agents in multimodal imaging and image-guided therapy.

  16. Design, demonstration and performance of a versatile electrospray aerosol generator for nanomaterial research and applications

    NASA Astrophysics Data System (ADS)

    Jennerjohn, Nancy; Eiguren-Fernandez, Arantzazu; Prikhodko, Sergey; Fung, David C.; Hirakawa, Karen S.; Zavala-Mendez, Jose D.; Hinds, William; Kennedy, Nola J.

    2010-06-01

    Carbon nanotubes are difficult to aerosolize in a controlled manner. We present a method for generating aerosols not only of carbon nanotubes, but also of many reference and proprietary materials including quantum dots, diesel particulate matter, urban dust, and their mixtures, using electrospraying. This method can be used as a teaching tool, or as the starting point for advanced research, or to deliver nanomaterials in animal exposure studies. This electrospray system generates 180 µg of nanotubes per m3 of carrier gas, and thus aerosolizes an occupationally relevant mass concentration of nanotubes. The efficiency achievable for single-walled carbon nanotubes is 9.4%. This system is simple and quick to construct using ordinary lab techniques and affordable materials. Since it is easy to replace soiled parts with clean ones, experiments on different types of nanomaterial can be performed back to back without contamination from previous experiments. In this paper, the design, fabrication, operation and characterization of our versatile electrospray method are presented. Also, the morphological changes that carbon nanotubes undergo as they make the transition from dry powders to aerosol particles are presented.

  17. Mass spectrometric detection of trace anions: The evolution of paired-ion electrospray ionization (PIESI).

    PubMed

    Breitbach, Zachary S; Berthod, Alain; Huang, Ke; Armstrong, Daniel W

    2016-01-01

    The negative-ion mode of electrospray ionization mass spectrometry (ESI-MS) is intrinsically less sensitive than the positive-ion mode. The detection and quantitation of anions can be performed in positive-ion mode by forming specific ion-pairs during the electrospray process. The paired-ion electrospray ionization (PIESI) method uses specially synthesized multifunctional cations to form positively charged adducts with the anions to be analyzed. The adducts are detected in the positive-ion mode and at higher m/z ratios to produce excellent signal-to-noise ratios and limits of detection that often are orders of magnitude better than those obtained with native anions in the negative-ion mode. This review briefly summarizes the different analytical approaches to detect and separate anions. It focuses on the recently introduced PIESI method to present the most effective dicationic, tricationic, and tetracationic reagents for the detection of singly and multiply charged anions and some zwitterions. The mechanism by which specific structural molecular architectures can have profound effects on signal intensities is also addressed.

  18. Corona discharges with water electrospray for Escherichia coli biofilm eradication on a surface.

    PubMed

    Kovalova, Zuzana; Leroy, Magali; Kirkpatrick, Michael J; Odic, Emmanuel; Machala, Zdenko

    2016-12-01

    Low-temperature plasma (cold), a new method for the decontamination of surfaces, can be an advantageous alternative to the traditional chemical methods, autoclave or dry heat. Positive and negative corona discharges in air were tested for the eradication of 48-h Escherichia coli biofilms grown on glass slides. The biofilms were treated by cold corona discharge plasma for various exposure times. Water electrospray from the high voltage electrode was applied in some experiments. Thermostatic cultivation of the biofilm, and confocal laser scanning microscopy (CLSM) of the biofilm stained with fluorescent dyes were used for biocidal efficiency quantification. Up to 5 log10 reduction of bacterial concentration in the biofilm was measured by thermostatic cultivation after exposure to both corona discharges for 15min. This decontamination efficiency was significantly enhanced by simultaneous water electrospray through the plasma. CLSM showed that the live/dead ratio after treatment remained almost constant inside the biofilm; only cells on the top layers of the biofilm were affected. DAPI fluorescence showed that biofilm thickness was reduced by about 1/3 upon exposure to the corona discharges with electrospray for 15min. The biofilm biomass loss by about 2/3 was confirmed by crystal violet assay.

  19. Atmospheric Pressure Ionization Using a High Voltage Target Compared to Electrospray Ionization

    NASA Astrophysics Data System (ADS)

    Lubin, Arnaud; Bajic, Steve; Cabooter, Deirdre; Augustijns, Patrick; Cuyckens, Filip

    2017-02-01

    A new atmospheric pressure ionization (API) source, viz. UniSpray, was evaluated for mass spectrometry (MS) analysis of pharmaceutical compounds by head-to-head comparison with electrospray ionization (ESI) on the same high-resolution MS system. The atmospheric pressure ionization source is composed of a grounded nebulizer spraying onto a high voltage, cylindrical stainless steel target. Molecules are ionized in a similar fashion to electrospray ionization, predominantly producing protonated or deprotonated species. Adduct formation (e.g., proton and sodium adducts) and in-source fragmentation is shown to be almost identical between the two sources. The performance of the new API source was compared with electrospray by infusion of a mix of 22 pharmaceutical compounds with a wide variety of functional groups and physico-chemical properties (molecular weight, logP, and pKa) in more than 100 different conditions (mobile phase strength, solvents, pH, and flow rate). The new API source shows an intensity gain of a factor 2.2 compared with ESI considering all conditions on all compounds tested. Finally, some hypotheses on the ionization mechanism, similarities, and differences with ESI, are discussed.

  20. Physicochemical characterization of atorvastatin calcium/ezetimibe amorphous nano-solid dispersions prepared by electrospraying method.

    PubMed

    Jahangiri, Azin; Barzegar-Jalali, Mohammad; Javadzadeh, Yousef; Hamishehkar, Hamed; Adibkia, Khosro

    2016-07-13

    In the present study, electrospraying was applied as a novel method for the fabrication of amorphous nano-solid dispersions (N-SDs) of atorvastatin calcium (ATV), ezetimibe (EZT), and ATV/EZT combination as poorly water-soluble drugs. N-SDs were prepared using polyvinylpyrrolidone K30 as an amorphous carrier in 1:1 and 1:5 drug to polymer ratios and the total solid (including drug and polymer) concentrations of 10 and 20% (w/v). The prepared formulations were further investigated for their morphological, physicochemical, and dissolution properties. Scanning electron microscopy studies indicated that the morphology and diameter of the electrosprayed samples (ESs) were influenced by the solution concentration and drug:polymer ratio, so that an increase in the solution concentration resulted in fiber formation while an increase in the polymer ratio led to enhancement of the particle diameter. Differential scanning calorimetry and X-ray powder diffraction studies together with in vitro dissolution test revealed that the ESs were present in an amorphous form with improved dissolution properties. Infrared spectroscopic studies showed hydrogen-bonding interaction between the drug and polymer in ESs. Since the electrospraying method benefits from the both amorphization and nanosizing effect, this novel approach seems to be an efficient method for the fabrication of N-SDs of poorly water-soluble drugs.